WorldWideScience
1

Improved FNAL linac beam choppers  

Energy Technology Data Exchange (ETDEWEB)

A discussion is presented of the 750-KeV chopper experience with both proton and negative ion beams and the ability of these systems to tailor the Linac beam to the diverse requirements of its users; normal accelerator injection, neutron therapy beam, and electron cooling experiments. This flexibility plus a cleaner beam pulse, improved thyratron operation, and mechanical modularity are the results of recent improvements. Additional benefits have been increased reliability and ease of service to the 750-KeV chopper. 3 refs.

1981-06-01

2

IFA-2 collective ion accelerator experiments  

Energy Technology Data Exchange (ETDEWEB)

Ion acceleration has now been demonstrated with the IFA-2 collective ion accelerator system. The IFA-2 system is described, photoionization experiments are summarized, and ion results are presented. Using a 1 MeV electron beam and a 30 cm acceleration length, IFA-2 has produced 5 MeV H/sup +/, 10 MeV D/sup +/, and 20 MeV He/sup + +/. This means that accelerating fields of 33 MV/m over 30 cm have been achieved with a controlled collective accelerator for the first time.

1985-10-01

3

Evaluation of the residual radiation field in the proton accelerator facility of the Proton Engineering Frontier Project (PEFP) in Korea  

British Library Electronic Table of Contents (United Kingdom)

In Korea, the Proton Engineering Frontier Project (PEFP) is building a proton linear accelerator facility with energy up to 100MeV and a beam current of 20mA. In this study, a radiation field after shutdown in the accelerator facility of the PEFP was evaluated for the purpose of the radiation shielding by using MCNPX code. A facility modeling was performed for the accelerator tunnel building, accelerator chain, target rooms and beam experiment hall. And radiation source terms were evaluated in the facility. With this facility, model and radiation source terms, the concentration of 41Ar was evaluated and the cooling time satisfying regulation in Korea was calculated.

2007-01-01

4

Analysis of longitudinal bunching in an FEL driven two-beam accelerator  

Energy Technology Data Exchange (ETDEWEB)

Recent experiments have explored the use of a free-electron laser (FEL) as a buncher for a microwave two-beam accelerator, and the subsequent driving of a standing-wave rf output cavity. Here the authors present a deeper analysis of the longitudinal dynamics of the electron bunches as they are transported from the end of the FEL and through the output cavity. In particular, the authors examine the effect of the transport region and cavity aperture to filter the bunched portion of the beam.

2000-08-01

5

Free electron laser experiments using a long pulse induction linac  

International Nuclear Information System (INIS)

The NRL Long Pulse Induction Linac is being employed in a Free Electron Laser (FEL) experiment. The authors present results of beam transport and focusing experiments as well as measurements of the output radiation generated by various magnetic wigglers. The electron gun of the accelerator presently has a 17-cmdiam. cold cathode which is located in a nearly zero magnetic field (B /SUB z/ less than or equal to 5 G). The gun voltage is flat to within approx. = + or - 5% for 1.5 #mu#sec with this graphite brush cathode. The beam is focused by a series of solenoidal coils as it propagates through the 4-m-long accelerator."2 A solenoidal field which can be varied from 1-10 kG confines the beam in the FEL interaction region. Previous experiments were limited by poor beam transport, focusing, and matching ...

6

Collective ion acceleration by a reflexing electron beam: model and scaling. Memorandum report  

Energy Technology Data Exchange (ETDEWEB)

Analytical and numerical calculations are presented for a reflexing electron beam type of collective ion accelerator. These results are then compared to those obtained through experiment. By constraining one free parameter to experimental conditions, the self-similar solution of the ion energy distribution agrees closely with the experimental distribution. Hence the reflexing beam model appears to be a valid model for explaining the experimental data. Simulation shows in addition to the agreement with the experimental ion distribution that synchronization between accelerated ions and electric field is phase unstable. This instability seems to further restrict the maximum ion energy to several times the electron energy.

1984-05-11

7

Development of mini-LIA and primary experiments  

International Nuclear Information System (INIS)

Mini-LIA is a miniature of a linear induction accelerator developed by China Academy of Engineering Physics and Tsinghua University in 2007. It has been constructed with a thermionic cathode in an electron injector and a metglas core in the induction accelerator cavities. A double-pulsed electron beam was produced for the first time in China on the Mini-LIA with a thermionic cathode in the electron gun and a metglas core in the induction accelerator cavities. A double-pulsed beam current of more than 1.1A was obtained on condition of 80 kV double-pulsed high voltage produced by pulsed power system supplying to the injector and accelerating modules. Some primary experiments for measuring the parameters of Mini-LIA has been performed, and some beam characterizations of Mini-LIA are presented. Further improvement is ...

2009-09-01

8

Beam extraction studies at 900 GeV using a channeling crystal  

CERN Document Server

Luminosity-driven channeling extraction has been observed for the first time in a 900 GeV study at the Fermilab Tevatron. This experiment, Fermilab E853, demonstrated that useful TeV level beams can be extracted from a superconducting accelerator during high luminosity collider operations without unduly affecting the background at the collider detectors. Multi-turn extraction was found to increase significantly the efficiency of the process. The beam extraction efficiency was about 25%. Studies of time dependent effects found that the turn-to-turn structure was governed mainly by accelerator beam dynamics. An investigation of a pre-scatterer using the accelerator flying wire system showed that a fiber could produce a significant extracted flux, consistent with expectations. Based on these results, it is feasible to construct a parasitic 5-10 ...

1999-01-01

9

A beam funnelling demonstration: Experiment and simulation  

Energy Technology Data Exchange (ETDEWEB)

Accelerator concepts for heavy-ion fusion require small emittance, high-current beams. Such applications could include funnels in which high-current, like-charged particle beams are interlaced to double beam current while retaining small emittances. The first experimental demonstration confirming the beam dynamics of the funnel principle was recently completed at Los Alamos National Laboratory. A single-leg prototype 5-MeV, H{sup {minus}} funnel was successfully tested. This single-beam demonstration explored physics issues of a two-beam funnel. It contained elements for emittance control, position control, and rf deflection, as well as diagnostics for measurement of beam intensity, position and angle centroids, energy and phase centroids, and transverse and longitudinal phase-space distributions. Results of the ...

1990-01-01

10

Twenty Years of Tevatron Operation  

Energy Technology Data Exchange (ETDEWEB)

The superconducting Tevatron accelerator at Fermi National Accelerator Laboratory (Fermilab) has surpassed twenty years of operation. The Tevatron is still the highest energy particle accelerator in the world and will remain so until the commissioning of the LHC in Europe later this decade. The Tevatron has operated in a Fixed Target mode, accelerating a proton beam into stationary targets/detectors, as well as a Colliding Beam mode, continuously colliding counter rotating beams of protons and antiprotons. Upon completion, the Tevatron cryogenic system became the world's largest helium refrigeration system. In 1993, the Tevatron cryogenic system was given the designation of International Historic Mechanical Engineering Landmark by the American Society of Mechanical Engineers. The operational history, experiences ...

2004-07-15

11

Beam stability study based on the beam trajectory jitter in the KEKB injector linac  

International Nuclear Information System (INIS)

... Tsukuba, Ibaraki (Japan) 389 p. PARTICLE ACCELERATORS beam monitoring

2001-08-01

12

The new Tevatron beam position monitor front-end software  

Energy Technology Data Exchange (ETDEWEB)

The Tevatron is a proton anti-proton accelerator collider operating at the Fermi National Accelerator Laboratory. The machine is currently delivering beam for the CDF and D0 experiments, which expect increasing luminosity until the conclusion of Run II, planned for 2009. The Laboratory defined a plan for achieving higher luminosity, and one of the tasks is the upgrade of the accelerator's beam position monitor (BPM). The Tevatron was built during the early eighties and some of its control systems, including the BPMs, are still the original ones. This paper describes the front-end software of the Tevatron BPM upgrade, from the requirements to the implementation, and the underlying hardware setup. The front-end software designed is presented, emphasizing its modularity and reusability, allowing it to be applied to other Fermilab machines.

2005-05-01

13

Pencil-like mm-size electron beams produced with linear inductive voltage adders  

International Nuclear Information System (INIS)

We present the design, analysis, and results of the high brightness electron beam experiments currently under investigation at Sandia National Laboratories. The anticipated beam parameters are the following: energy 12 MeV, current 35 endash 40 kA, rms radius 0.5 mm, and pulse duration 40 ns full width at half-maximum. The accelerator is SABRE, a pulsed linear inductive voltage adder modified to higher impedance, and the electron source is a magnetically immersed foilless electron diode. 20 endash 30 T solenoidal magnets are required to insulate the diode and contain the beam to its extremely small-sized (1 mm) envelope. These experiments are designed to push the technology to produce the highest possible electron current in a submillimeter radius beam. Design, numerical simulations, and experimental results are presented. copyright 1997 ...

14

Accelerators for proton and heavy ion radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

The construction of Heavy Ion Medical Accelerator in Chiba (HIMAC) at the National Institute of Radiological Sciences was completed in December 1993. HIMAC consists of an injector linac, two synchrotron rings, a high energy beam transport system and a beam irradiation system. Its accelerator parameters are based on the medical requirement, and helium, carbon, neon, silicon and argon were selected as the accelerated ion species. It has 3 therapy rooms (A{approx}C). Room A has a vertical irradiation system, Room C horizontal and Room B both vertical and horizontal. Two rings can supply beams independently to the vertical and horizontal irradiation systems. Clinical trial started on June 21 1994, after several basic biological and physics experiments lasting about 2 months. Cancer is the top cause of death in Japan since 1981, and people expect ...

1995-03-01

15

Steering of high energy negative ion beam and design of beam focusing/deflection compensation for JT-60U large negative ion source  

Energy Technology Data Exchange (ETDEWEB)

A large negative ion source for JT-60U produces high current ion beam from a wide extraction area of 45 cm x 110 cm. On the other hand, a cross-sectional area of the negative ion based neutral beam (NNB) injection port on JT-60U is narrow, about 50 cm x 60 cm. In order to inject the neutral beam at a high geometric efficiency, i.e. to suppress beam loss in the beamline, it is necessary to steer the beam for both compensation of undesirable beam deflection in extractor and focusing of the beam. For the JT-60U, two methods are provided for the required beam steering. Among them the results of beam steering experiment by aperture displacement and the design study are summarized in the present report. The experiment was carried out with 400 keV negative ion ...

2000-03-01

16

Physics of electron beam therapy  

International Nuclear Information System (INIS)

A book has been written to introduce the physical aspects of the radiotherapy electron beam by presenting a summary of the developments in this field. The first chapter is a brief introduction to the technology of medical accelerators with emphasis on the electron beam production facilities. Chapter 2 describes the interaction processes at the atomic level once the electron beam enters the medium. Chapter 3 is concerned with the various properties of the electron beam purely from the clinical point of view. The electron beam algorithms and models for distribution calculations are covered in Chapter 4 with inclusion of age diffusion and multiple scattering approaches. The factors affecting the beam distribution in a patient, with inhomogeneities, surface irregularities, backscattering etc. are discussed in Chapter 5. The last two chapters are ...

17

Dependence of proton beam polarization on ion source transition configurations  

Energy Technology Data Exchange (ETDEWEB)

The polarization of extracted SATURNE II proton beam as a function of different ion source configurations was studied. Two distinct experiments were necessary for this purpose. In the first one, the left-right instrumental asymmetry of the beam polarimeter was determined using an unpolarized beam. In the second one this correction factor was applied to asymmetries measured with the beam from the polarized ion source in all polarization states. The measurements were carried out at the proton beam kinetic energy 0.80 GeV, where the pp-elastic scattering analyzing power is near its maximum. The results confirmed that the two so-called ``unpolarized states`` of the source were polarized to several percent, whereas the absolute values of the beam polarizations in the so-called ``polarized states`` were equal and opposite. It was observed that the ...

1997-11-11

18

Beam-forming system for electrostatic accelerator  

International Nuclear Information System (INIS)

A simple beam-forming system is described for the electrostatic accelerator of the Scientific-Research Institute of Nuclear Physics of Moscow State University. The system allows the beam to be focused on targets at various distances for a conductor potential of from 1 to 4 MV and beam currents of up to 35 #mu# A.

1988-01-01

19

ANALYSIS OF ACCELERATOR BASED NEUTRON SPECTRA FOR BNCT USING PROTON RECOIL SPECTROSCOPY  

Energy Technology Data Exchange (ETDEWEB)

Boron Neutron Capture Therapy (BNCT) is a promising binary treatment modality for high-grade primary brain tumors (glioblastoma multiforme, GM) and other cancers. BNCT employs a boron-10 containing compound that preferentially accumulates in the cancer cells in the brain. Upon neutron capture by {sup 10}B energetic alpha particles and triton released at the absorption site kill the cancer cell. In order to gain penetration depth in the brain Fairchild proposed, for this purpose, the use of energetic epithermal neutrons at about 10 keV. Phase I/II clinical trials of BNCT for GM are underway at the Brookhaven Medical Research Reactor (BMRR) and at the MIT Reactor, using these nuclear reactors as the source for epithermal neutrons. In light of the limitations of new reactor installations, e.g. cost, safety and licensing, and limited capability for modulating the reactor based neutron beam energy spectra alternative neutron sources are being contemplated for wider ...

1998-11-06

20

Negative-ion based NBI system for JT-60U  

Energy Technology Data Exchange (ETDEWEB)

A 500 keV negative-ion based NBI system is under construction for NB current drive and plasma core heating in high density plasma in JT-60U. Part of the beamline and the high voltage power supply required for a verification test of an ion source was completed in March 1995. After having done a high potential test of the power supply, the negative-ion generation and acceleration tests started in June 1995 aiming at deuterium beams of 500 keV, 22A. In initial experiment, deuterium negative-ion beams of 410 keV, 6.1A (2.5 MW) for 0.2 sec, so far, have been achieved. This is the world highest D{sup {minus}} current and negative ion beam power. The construction of the total system will be completed by the beginning of 1996, and the beam injection will start in March 1996.

1995-12-31

21

Absolute calibration of the antiproton detection efficiency for BESS below 1 GeV  

Energy Technology Data Exchange (ETDEWEB)

An accelerator beam experiment was performed using a low-energy antiproton beam to measure antiproton detection efficiency of the BESS detector. Measured and calculated efficiencies derived from the BESS Monte Carlo simulation based on GRANT/GHEISHA showed good agreement. With detailed verification of the BESS simulation, the relative systematic error of detection efficiency derived from the BESS simulation has been determined to be {+-}5%, compared with the previous estimation of {+-}15% which was the dominant uncertainty for measurements of cosmic-ray antiproton flux. (author)

2001-12-01

22

Accelerator aspects of #gamma#-#gamma# colliders  

International Nuclear Information System (INIS)

There are several on-going projects of e"+e"- colliders. If they are constructed, we can convert them into photon-photon (#gamma#-#gamma#) colliders by converting electron beams into #gamma# beams, irradiating laser beams just before the interaction point. In this report we discuss the technical issues on the accelerator.

2000-11-21

23

Linac Coherent Light Source Experiments Commence  

British Library Electronic Table of Contents (United Kingdom)

The Linac Coherent Light Source [1] (LCLS) at SLAC National Accelerator Laboratory is preparing for the arrival of its first scientific users in the fall of 2009. LCLS is the world's first free-electron in the spectral range 800-8,000 eV, producing intense, sub-picosecond pulses of Xrays with very high spatial coherence. The accelerator facility has been commissioned in stages, beginning in April 2007 [2] with the injector linac and culminating in December 2008 [3] with the first transport of electrons through the complete beam path. On April 10, 2009, the LCLS Project team was rewarded for years of planning, design, construction, and checkout with a dream-come-true: as undulators were placed on the beam path one-by-one, the laser simply turned on without drama in the course of one hour [4...

2009-01-01

24

Design of a tandem accelerator free electron laser  

International Nuclear Information System (INIS)

The motivation for using a tandem electrostatic accelerator as an electron accelerator for a free electron laser (FEL) is presented. The adaptation of the HVEC EN tandem at the Weizmann Institute for this purpose, electron beam optics and nonlinear FEL computation relevant for this FEL realization are described. In the tandem configuration the terminal is held at a positive potential. The electron beam is accelerated from ground potential to the terminal in one beam tube and then decelerated down the other beam tube. The FEL wiggler and cavity are at the terminal. Due to the beam energy recovery this scheme produces a high power beam at the terminal with a small investment in electrical power. (orig.).

25

High-power radio frequency pulse generation and extraction based on wakefield excited by an intense charged particle beam in dielectric-loaded waveguides  

International Nuclear Information System (INIS)

Power extraction using a dielectric-loaded (DL) waveguide is a way to generate high-power radio frequency (RF) waves for future particle accelerators, especially for two-beam-acceleration. In a two-beam-acceleration scheme, a low-energy, high-current particle beam is passed through a deceleration section of waveguide (decelerator), where the power from the beam is partially transferred to trailing electromagnetic waves (wakefields); then with a properly designed RF output coupler, the power generated in the decelerator is extracted to an output waveguide, where finally the power can be transmitted and used to accelerate another usually high-energy low-current beam. The decelerator, together with the RF output coupler, is called a power extractor. At Argonne Wakefield Accelerator (AWA), we designed a 7.8GHz power ...

26

Preliminary Calculations of the Radiation Damage of the Permanent Magnets for TRADE (TRiga Accelerator Driven Experiment)  

CERN Document Server

Monte Carlo calculations of proton irradiation of permanent magnets for the TRADE experiment have been performed. An irradiation dose of about 4´106 Gy/yr/mA has been estimated due to beam losses in normal operating conditions. Existing experimental results indicate that this irradiation level may induce a considerable demagnetization: in fact, a dose of 6´107 Gy induces a remanence loss of 0.3 % on samples of Sm2Co17 magnets, which are the most resistant type. More detailed calculations with the final design of the magnets and of the beam line are suggested, to determine if the irradiation levels allowed a reliable operation of the permanent magnets for the entire duration of the TRADE experiment. Damage and gas production rates have also been calculated; the values obtained are very low, thus confirming that the demagnetization process is in great part reversible.

2002-01-01

27

Production by surface sputtering and acceleration of heavy negative ions in tandem accelerators  

Energy Technology Data Exchange (ETDEWEB)

The main physical processes allowing negative ion production by surface sputtering for further acceleration in tandem acceleration are briefly reviewed. The sputtering yield and the probability of negative ion ejection are discussed. The properties of negative ion beams for an efficient acceleration in tandem accelerators are also discussed, with an emphasis on space charge problems. The main features and performances of the heavy negative ion injector of the Bucharest tandem accelerator are given.

1992-10-05

28

Construction of a open-quotes black neutron detectorclose quotes at the University of Massachusetts-Lowell Accelerator Laboratory  

International Nuclear Information System (INIS)

In many experiments involving fast neutrons generated in nuclear reactions initiated by accelerator produced charged particle beams, it is important to be able to determine accurately the neutron yield from the target. A detector suitable for such applications should have: a constant efficiency over a large energy range; a fast time response; and the ability to discriminate between gamma rays and neutrons. The authors have constructed a open-quotes black neutron detectorclose quotes based on the design of Poenitz that has these characteristics. At the Lowell Van de Graaff accelerator laboratory neutrons are produced via the "7Li(p,n)"7Be reaction using a pulsed proton beam which impinges on metallic lithium targets. The pulsed beam enables the detector to be used in a time-of-flight spectrometer. Use of BC501 liquid scintillator permits neutron-gamma ...

1992-03-16

29

High voltage high brightness electron accelerator with MITL voltage adder coupled to foilless diode  

International Nuclear Information System (INIS)

The design and analysis of a high brightness electron beam experiment under construction at Sandia National Laboratory is presented. The beam energy is 12 MeV, the current 35 endash 40 kA, the rms radius 0.5 mm, and the pulse duration FWHM 40 ns. The accelerator is SABRE [J. Corley, J. A. Alexander, P. J. Pankuch, C. E. Heath, D. L. Johnson, J. J. Ramirez, and G. J. Denison, in Proceedings of the Eighth International IEEE Pulsed Power Conference, San Diego, California, 1991 (IEEE, New York, 1991), p. 920], a pulsed inductive voltage adder, and the electron source is a magnetically immersed foilless diode. This experiment has as its goal to stretch the technology to the edge and produce the highest possible electron current in a submillimiter radius beam. copyright 1996 American Institute of Physics.

1995-10-13

30

Free electron laser  

International Nuclear Information System (INIS)

The present article outlines major features of the free electron laser (FEL) and reviews research and development of FEL. Relations among the oscillation frequency, electron beam parameters and wiggler parameters, the physical mechanism of amplification and the physical process of saturation are discussed to identify the difference between FEL and other lasers. The report also outlines techniques for accelerators which are used to generate high-quality, high-energy electron beams required for FEL experiments. Techniques to achieve a short wavelength, high output and high efficiency, and applications of FEL are also discussed. FEL consists of an electron accelerator, wiggler and optical resonator. In FEL, electron beams with a relativistic energy interact resonantly with an electromagnetic field to generate coherent electromagnetic waves. Unlike conventional ...

31

Calibration methods of plane-parallel ionization chambers used in electron dosimetry; Metodos de calibracao de camaras de ionizacao de placas paralelas para dosimetria de feixes de eletrons  

Energy Technology Data Exchange (ETDEWEB)

The use of linear accelerators in radiotherapy is of great importance in Medicine, and according to international recommendations the electron beam dosimetry has to be performed using plane-parallel ionization chambers, previously calibrated in standard gamma radiation fields at accredited laboratories. In this work, calibration methods of plane-parallel ionization chambers used in dosimetry procedures of high energy electron beams of clinical accelerators were presented, tested and intercompared. The experiments were carried out using gamma radiation beams of {sup 60} Co at the Calibration Laboratory of Clinical Dosemeters at IPEN and electron beams od 4 to 16 MeV at the Radiotherapy Department of Hospital Israelita Albert Einstein, Sao Paulo. A method was chosen to be established at IPEN. Proposals of the calibration procedure, calibration ...

1999-07-01

33

Synchrotron radiation from electron beams in plasma-focusing channels.  

Science.gov (United States)

Spontaneous radiation emitted from relativistic electrons undergoing betatron motion in a plasma-focusing channel is analyzed, and applications to plasma wake-field accelerator experiments and to the ion-channel laser (ICL) are discussed. Important similarities and differences between a free electron laser (FEL) and an ICL are delineated. It is shown that the frequency of spontaneous radiation is a strong function of the betatron strength parameter a(beta), which plays a role similar to that of the wiggler strength parameter in a conventional FEL. For a(beta) > or approximately 1, radiation is emitted in numerous harmonics. Furthermore, a(beta) is proportional to the amplitude of the betatron orbit, which varies for every electron in the beam. The radiation spectrum emitted from an electron beam is calculated by averaging the single-electron spectrum over the electron distribution. This leads to a ...

2002-05-20

34

Large-Scale Simulation of Beam Dynamics in High Intensity Ion Linacs Using Parallel Supercomputers  

CERN Document Server

In this paper we present results of using parallel supercomputers to simulate beam dynamics in next-generation high intensity ion linacs. Our approach uses a three-dimensional space charge calculation with six types of boundary conditions. The simulations use a hybrid approach involving transfer maps to treat externally applied fields (including rf cavities) and parallel particle-in-cell techniques to treat the space-charge fields. The large-scale simulation results presented here represent a three order of magnitude improvement in simulation capability, in terms of problem size and speed of execution, compared with typical two-dimensional serial simulations. Specific examples will be presented, including simulation of the spallation neutron source (SNS) linac and the Low Energy Demonstrator Accelerator (LEDA) beam halo experiment.

2000-01-01

35

Smith-Purcell radiation in the highly relativistic regime  

International Nuclear Information System (INIS)

An electron moving over the surface of a diffraction grating will transfer a part of its kinetic energy to radiation via a velocity synchronous coupling with a slow space harmonic component of the field. Since the phase velocity of a slow space harmonic is less than the speed of light, the slow components decay exponentially, or evanesce, with distance above the grating and the evanescence scale is determined by the product of the relative velocity, #beta#, the relative energy, #gamma#, and the wavelength #lambda#. Thus, in the relativistic regime, good electron - grating coupling can be maintained at beam heights that are greater than the emitted wavelength. In order to explore this regime a series of experiments have been carried out with moderately energetic beams and an experiment with the 70-MeV beam at the Accelerator Test Facility is in the planning ...

1995-08-21

36

Electron accelerator unit for electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

An electron accelerator unit is described for electron beam therapy, comprising: a source of an electron beam; means for finally directing at least a portion of the beam to a therapy site, the directing means being mechanically independent of, and electrically isolated from, the source, and having a target area; and means for aligning the source with the directing means, the aligning means comprising means for projecting at least one beam of light from the source toward the target area.

1987-01-27

37

Electron accelerator unit for electron beam therapy  

International Nuclear Information System (INIS)

An electron accelerator unit is described for electron beam therapy, comprising: a source of an electron beam; means for finally directing at least a portion of the beam to a therapy site, the directing means being mechanically independent of, and electrically isolated from, the source, and having a target area; and means for aligning the source with the directing means, the aligning means comprising means for projecting at least one beam of light from the source toward the target area.

38

Accelerator-based analytical techniques using ion and photon beams. Environmental and industrial applications  

International Nuclear Information System (INIS)

An overview of different Ion Beam Analysis (IBA) techniques is given. Examples of applications of the PIXE techniques to various types of samples are presented. (author)

1999-11-01

39

Accelerator related background in the CMS detector at LHC  

International Nuclear Information System (INIS)

Complete calculations of the accelerator related background in the muon spectrometer of the CMS detector at the Large Hadron Collider are presented. The simulations have been performed with the STRUCT multi-turn tracking code and the MARS and FLUKA cascade codes taking into account latest information of the LHC lattice, vacuum conditions, beam cleaning system and the shielding and layout of the CMS experiment. Beam loss distributions in the interaction regions and their vicinities and their contribution to the background levels in the muon spectrometer of CMS are analyzed. The studies show that hadronic and electromagnetic components of machine background are efficiently suppressed by the proposed CMS shielding. High energy muons penetrate through the shielding, but in positions of significance they do not contribute more than a few percent compared to the background generated by the pp-collisions. It ...

40

A General Model of the Resistive Wall Instability in Linear Accelerators  

Energy Technology Data Exchange (ETDEWEB)

A general model for wakefield-generated instabilities in linear accelerators, originally developed for cumulative beam breakup [1], is applied to the resistive wall instability. The general solution for various bunch charge distributions and application to various accelerator configurations are presented.

2007-01-08

42

Status of LBL/LLNL FEL (free electron laser) research for two beam accelerator applications  

Energy Technology Data Exchange (ETDEWEB)

We review the status of free electron laser (FEL) research being conducted at LBL and LLNL as part of a broader program of research on two beam accelerators (TBAs). Induction accelerator-driven FELs for use as power sources for high-gradient accelerators are discussed, along with preliminary cost estimates for this type of power source. Finally, a promising new version of an FEL/TBA is described. 25 refs., 1 fig., 3 tabs.

1989-03-01

43

Tune resonance phenomena in the SPS and machine protection via fast position interlocking  

Energy Technology Data Exchange (ETDEWEB)

The 6911 m long Super Proton Synchrotron (SPS) at CERN with a peak energy of 450 GeV is at the top of the LHC preaccelerator-complex. Apart from the LHC, the SPS is with the Tevatron the accelerator with the largest stored beam energy of up to 2.5 MJ. The SPS has a known vulnerability to fast equipment failures that led to an uncontrolled loss of a high intensity beam in 2008, which resulted in major damage of a main dipole. The beam loss was caused by a fast tune decrease towards an integer resonance. Simulations and distinct experimental studies provide clear understanding of the beam dynamics at different SPS tune resonances. Diverging closed orbit oscillations, dispersion explosion and increased beta-beating are the driving effects that lead to a complete beam loss in as little as 10 turns (230 {mu}s) after reaching the stop band of the resonance. Dedicated ...

2010-07-01

44

Tune resonance phenomena in the SPS and machine protection via fast position interlocking  

International Nuclear Information System (INIS)

The 6911 m long Super Proton Synchrotron (SPS) at CERN with a peak energy of 450 GeV is at the top of the LHC preaccelerator-complex. Apart from the LHC, the SPS is with the Tevatron the accelerator with the largest stored beam energy of up to 2.5 MJ. The SPS has a known vulnerability to fast equipment failures that led to an uncontrolled loss of a high intensity beam in 2008, which resulted in major damage of a main dipole. The beam loss was caused by a fast tune decrease towards an integer resonance. Simulations and distinct experimental studies provide clear understanding of the beam dynamics at different SPS tune resonances. Diverging closed orbit oscillations, dispersion explosion and increased beta-beating are the driving effects that lead to a complete beam loss in as little as 10 turns (230 #mu#s) after reaching the stop band of the resonance. Dedicated ...

2010-03-15

45

Collective acceleration of electrons and ions in a high current relativistic electron beam. Final report  

International Nuclear Information System (INIS)

The original purpose of this research was an investigation into the use of slow space charge waves on weakly relativistic electron beams for ion acceleration. The work had three main objectives namely, the development of a suitable ion injector, the growth and study of the properties of slow space charge waves on an electron beam, and a combination of the two components parts into a suitable proof of principle demonstration of the wave accelerator. This work focusses on the first two of these objectives.

46

Proton beam monitoring and forming on the target of isotope complex at INR linac  

International Nuclear Information System (INIS)

Special beam extraction channel is used at INR linac for isotope production. It starts from 160 MeV measuring and matching area of accelerator. This choice of beam extraction enables to direct to the target of isotope complex a proton beam of wide energy range up to 160 MeV. It is important for production of different types of nuclides. The measuring results of proton beam behavior in this region are presented. Required beam forming in 160 MeV measuring and matching area of accelerator and in beam extraction channel is discussed.

2010-01-01

47

Measurement of low-energy antiproton detection efficiency in BESS below 1 GeV  

Energy Technology Data Exchange (ETDEWEB)

An accelerator experiment was performed using a low-energy antiproton beam to measure antiproton detection efficiency of BESS, a balloon-borne spectrometer with a superconducting solenoid. Measured efficiencies showed good agreement with calculated ones derived from the BESS Monte Carlo simulation based on GEANT/GHEISHA. With detailed verification of the BESS simulation, the relative systematic error of detection efficiency derived from the BESS simulation has been determined to be {+-}5%, compared with the previous estimation of {+-}15% which was the dominant uncertainty for measurements of cosmic-ray antiproton flux.

2002-08-21

48

Identification of the #pi#g_9_/_2 band new levels in "1"2"1Cs  

International Nuclear Information System (INIS)

The #pi#g_9_/_2 band structure in "1"2"1Cs is obtained. The experiment was performed at the HI-13 MV tandem accelerator of China Institute of Atomic Energy. The excited states of "1"2"1Cs were populated via the reaction "1"1"2Sn("1"2C, p2n). The #gamma#-#gamma# coincidence data were taken with five BGO-AC HpGe detectors at beam energy of 60 Mev. The energy-level schemes of "1"2"1Cs is presented.

1992-01-01

49

DIPAC 2005 7. European workshop on beam diagnostics and instrumentation for particle accelerators  

Energy Technology Data Exchange (ETDEWEB)

Accelerators can not be improved without the development of adequate beam instruments and diagnostic tools. This year this statement is particularly right: a lot of contributions are dedicated to beam monitoring and to the design of new beam monitors based on original technologies. This document gathers about 100 contributions.

2005-07-01

50

Halogens for negative ion beams and ion-ion plasmas  

International Nuclear Information System (INIS)

Negative ions have attractive features as drivers for inertial confinement fusion, because they will avoid electron cloud effects, and could be efficiently photodetached to neutrals after the final focus, which could also be beneficial in heating warm dense matter targets. The halogens have large electron affinities, and thus should be able to produce high current densities of relatively robust negative ions. Recent experiments comparing chlorine beams to argon beams using the same source, extraction optics, and diagnostics have demonstrated that Cl"- beams can be produced with similar emittance to Ar"+ beams, and with about 34 the current density from the same configuration. The observed effective beam temperature of about 13eV, and the similarity of current densities show that negative halogen beams can meet the current density and ...

2007-07-01

51

Analysis of beam emittance in FEL (Free Electron Laser)  

International Nuclear Information System (INIS)

To achieve high efficiency for the conversion of electron kinetic energy in an electron beam to electromagnetic energy in a Free Electron Laser (FEL), it is important to improve the beam quality. And hence, it is necessary to study and minimize the emittance growth of the beam. According to the requirements for the beam quality in an FEL, the author analyzed the emittance growth caused by the jump of the electric field in an accelerator, energy increase, wakefield in a waveguide, space charge effect and distribution of particles in a beam as well as the wakefield in a deflect system etc. The author also estimated the emittance change caused by the variation of the microwave field from the gun to the first accelerator for such case.

52

Neutrino cross sections with the MINER?A Experiment  

British Library Electronic Table of Contents (United Kingdom)

MINER?A is a high resolution, fully active detector designed to study neutrino interactions on nuclei in the NuMI beam at Fermi National Accelerator Laboratory. The active volume of the detector consists of 3 tons of plastic scintillator and includes embedded targets of 4He, C, H2O, Fe and Pb. The MINER?A collaboration expects to perform precision, A-dependent neutrino cross section measurements in the 1?10 GeV region, measure the axial form factor, and study nuclear shadowing of F2, quark-hadron duality and coherent pion production, among other topics. MINER?A began data taking in the fall of 2009. This paper describes the MINER?A experiment and provides an overview of the physics objectives along with estimated uncertainties of the measurements and the tentative projected schedule of dat...

2011-01-01

53

High energy beams of radioactive nuclei and their biomedical applications  

Energy Technology Data Exchange (ETDEWEB)

It is possible to produce energetic beams of radioactive nuclei, as secondary beams, from the heavy-particle compound accelerator called BEVALAC. These beams can be focused into experimental areas without significant contamination using suitable magnetic filters and proper beam-optics. Properly selected high-energy beams of radioactive nuclei (those which defay by positron emission) can provide a truly unique opportunity to evaluate the effectiveness of these beams in localizing the Bragg peak on a tumor volume - necessary in heavy-particle therapy. Preliminary data are presented here to demonstrate the possible use of these beams in radiotherapy treatment-planning verification.

1981-04-01

54

Evaluation of tritium diffusion through the Neutral Beam Injector calorimeter panel  

Energy Technology Data Exchange (ETDEWEB)

The Neutral Beam Test Facility (NBTF) to be realized in Padoa will test the Neutral Beam Injection (NBI), one of the Heating and Current Drive Systems foreseen for ITER. The NBI is based on the acceleration of hydrogen or deuterium negative ions up to 1 MeV. This work has been aimed at assessing the tritium release from the NBTF in order to provide data for the safety analysis. In particular, the diffusion of the tritium through the neutral beam target material (the CuCrZr alloy calorimeter panels) has been assessed by using literature data of the diffusion coefficient. The tritium generated inside the calorimeter panels moves into both the vacuum and water side: the tritium diffusion flux has been evaluated during the beam-on (200 deg. C) and the beam-off (20 deg. C) phases of the NBTF experiments consisting of an interim campaign and a ...

2009-06-15

55

Evaluation of tritium diffusion through the Neutral Beam Injector calorimeter panel  

International Nuclear Information System (INIS)

The Neutral Beam Test Facility (NBTF) to be realized in Padoa will test the Neutral Beam Injection (NBI), one of the Heating and Current Drive Systems foreseen for ITER. The NBI is based on the acceleration of hydrogen or deuterium negative ions up to 1 MeV. This work has been aimed at assessing the tritium release from the NBTF in order to provide data for the safety analysis. In particular, the diffusion of the tritium through the neutral beam target material (the CuCrZr alloy calorimeter panels) has been assessed by using literature data of the diffusion coefficient. The tritium generated inside the calorimeter panels moves into both the vacuum and water side: the tritium diffusion flux has been evaluated during the beam-on (200 deg. C) and the beam-off (20 deg. C) phases of the NBTF experiments consisting of an interim campaign and a ...

2009-06-01

56

MTX final report  

Energy Technology Data Exchange (ETDEWEB)

The MTX experiment was proposed in 1986 to apply high frequency microwaves generated by a free-electron laser (FEL) to electron cyclotron resonance heating (ECRH) in a high field, high density tokamak. As the absorption of microwaves at the electron cyclotron resonance requires high frequencies, the opportunity of applying a free-electron laser has appeal as the device is not limited to frequencies in the microwave or long millimeter wavelength regions, in contrast to many other sources. In addition, the FEL is inherently a high power source of microwaves, which would permit single units of 10 MW or more, optimum for reactors. Finally, it was recognized early in the study of the application of the FEL based on the induction linear accelerator, that the nonlinear effects associated with the intense pulses of microwaves naturally generated would offer several unique opportunities to apply ECRH to current drive, MHD control, and other plasma ...

1994-01-01

57

The physics of production, acceleration and neutralization of large negative ion beams  

Energy Technology Data Exchange (ETDEWEB)

Neutral beam systems for the next generation of magnetic fusion devices will be based on negative ions. Development are progressing steadily, and large negative ion-based systems are prepared for JT60-U and LHD, and are being considered for ITER. An overview of the physics of the production, acceleration and neutralization of large negative ion beams is given. the present state of the art in Research and Development is also surveyed. (author). 55 refs., 10 figs., 1 tab.

1995-12-31

58

The physics of production, acceleration and neutralization of large negative ion beams  

Energy Technology Data Exchange (ETDEWEB)

Neutral beam systems for the next generation of magnetic fusion devices will be based on negative ions. Developments are progressing steadily, and large negative ion-based systems are under preparation for JT60-U and LHD, and are being considered for ITER. An overview of the physics of the production, acceleration and neutralization of large negative ion beams is given. The present state of the art in R and D is also surveyed. (Author).

1995-11-01

59

Electron beam and high-speed optical diagnostics for the Los Alamos HIBAF (High Brightness Accelerator FEL) Facility  

Energy Technology Data Exchange (ETDEWEB)

Characterization of the electron beam's properties will be a major task after the upgrade of the Los Alamos Free-Electron Laser (FEL) Facility with a photoelectric injector (PEI) and increased acceleration capability to 40 MeV. Adjustments to the previous diagnostics package that address the lower beam emittance, higher energy, and wakefield source reduction issues will be discussed. 6 refs., 8 figs., 1 tab.

1989-01-01

60

Accelerator aspects of {gamma}-{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

There are several on-going projects of e{sup +}e{sup -} colliders. If they are constructed, we can convert them into photon-photon ({gamma}-{gamma}) colliders by converting electron beams into {gamma} beams, irradiating laser beams just before the interaction point. In this report we discuss the technical issues on the accelerator.

2000-11-21

61

Maximum proton kinetic energy and patient-generated neutron fluence considerations in proton beam arc delivery radiation therapy  

UK PubMed Central (United Kingdom)

Several compact proton accelerator systems for use in proton therapy have recently been proposed. Of paramount importance to the development of such an accelerator system is the maximum kinetic energy...Full Text Available

2009-02-01

62

Beam Profile Measurement and its Application to Calculate Beam Emittance Using Wire Scanner for the PEFP 20MeV linac  

International Nuclear Information System (INIS)

A 20-MeV proton accelerator is developed by Proton Engineering Frontier Project (PEFP) at Korea Atomic Energy Research Institute (KAERI). The 20MeV accelerator consists of 50keV proton injector, 3MeV RFQ (Radio frequency Quadrupole), 20MeV DTL (Drift Tube Linac) and 20MeV beam line. The beam profile was measured at the end of the 20MeV beam line with wire scanner. Moreover the beam emittance was calculated from the quad scan method using beam line quadrupole magnets. In this paper, the beam profile measurement results are presented and the emittance measurement from the quad scan method is discussed

2010-10-01

63

Fermilab Steering Group Report  

Energy Technology Data Exchange (ETDEWEB)

The Fermilab Steering Group has developed a plan to keep U.S. accelerator-based particle physics on the pathway to discovery, both at the Terascale with the LHC and the ILC and in the domain of neutrinos and precision physics with a high-intensity accelerator. The plan puts discovering Terascale physics with the LHC and the ILC as Fermilab's highest priority. While supporting ILC development, the plan creates opportunities for exciting science at the intensity frontier. If the ILC remains near the Global Design Effort's technically driven timeline, Fermilab would continue neutrino science with the NOVA experiment, using the NuMI (Neutrinos at the Main Injector) proton plan, scheduled to begin operating in 2011. If ILC construction must wait somewhat longer, Fermilab's plan proposes SNuMI, an upgrade of NuMI to create a more powerful neutrino beam. If the ILC start is postponed ...

2007-01-01

64

Radiation hardening of diagnostics  

International Nuclear Information System (INIS)

The world fusion program has advanced to the stage where it is appropriate to construct a number of devices for the purpose of burning DT fuel. In these next-generation experiments, the expected flux and fluence of 14 MeV neutrons and associated gamma rays will pose a significant challenge to the operation and diagnostics of the fusion device. Radiation effects include structural damage to materials such as vacuum windows and seals, modifications to electrical properties such as electrical conductivity and dielectric strength and impaired optical properties such as reduced transparency and luminescence of windows and fiber optics during irradiation. In preparation for construction and operation of these new facilities, the fusion diagnostics community needs to work with materials scientists to develop a better understanding of radiation effects, and to undertake a testing program aimed at developing workable solutions for this multi-faceted problem. A unique ...

65

Observations of plasma wave turbulence generated around large ionospheric spacecraft: Effects of motionally induced EMF and of electron beam emission  

International Nuclear Information System (INIS)

The authors report on observations of plasma wave turbulence generated during electron beam injections, spacecraft potential variations, and neutral gas emissions of the CHARGE 2 sounding rocket experiment. The payload was flown in a mother/daughter configuration, with the two sub-payloads electrically connected by an insulated, conducting tether. While tethered, the two platforms were separated, drifting apart in a direction perpendicular to both the magnetic field and to the spacecraft velocity, reaching a maximum distance of 426 m at the end of the flight. The mother carried a high-voltage (HV) system (0-460 V), biasing the mother negative relative to the daughter. The operation of the HV bias system simulated the motional emf induced in larger orbiting space structures like the Tethered Satellite System 1 (TSS 1) space shuttle mission scheduled for the spring of 1992. In addition, the mother carried an electron beam ...

66

NuMI proton beam diagnostics and control: achieving 2 megawatt capability  

Energy Technology Data Exchange (ETDEWEB)

The NuMI proton beam at Fermilab currently delivers 120 GeV protons to the neutrino production target with design beam power capability to 400 kW. Upgrade capability to 700 kW is being prepared, with planning toward delivering 2.3 MW beam provided by the Project X accelerator upgrade plan. We report on the system of beam diagnostics and control used in operation of the NuMI beam. Also considered are the steps to provide a robust system for transport and targeting beam of 2 MW and beyond.

2008-10-01

67

Photon dosimetry using plastic scintillators in pulsed radiation fields  

Energy Technology Data Exchange (ETDEWEB)

Simulations and experiments have been carried out to explore using a plastic scintillator as a dosimetry probe in the vicinity of a pulsed bremsstrahlung source in the range 4 to 20 MeV. Taking advantage of the tissue-equivalent properties of this detector in conjunction with the use of a fast digital signal processor near real-time dosimetry was shown to be possible. The importance of accounting for a broad energy electron beam in bremsstrahlung production, and photon scattering and build-up, in correctly interpreting dosimetry results at long stand-off distances is highlighted by comparing real world experiments with ideal geometry simulations. Close agreement was found between absorbed energy calculations based upon spectroscopic techniques and calculations based upon signal integration, showing a ratio between 10 MeV absorbed dose to 12 MeV absorbed dose of 0.66 at a distance of 91.4 m from the ...

2007-04-01

70

Electron accelerators, present and future applications  

International Nuclear Information System (INIS)

The development and occurrence of new electron accelerators and applications are according to the human society development law, as a whole. The period of economic standstill is generating an intense creative activity in the domain of science and engineering which also resulting in great achievements in the field of electron accelerators. This paper presents the basic principle of the electron beam applications and the accelerators required characteristics for their present and potential applications in the domains: radiation sources, diagnostics, radiation processing, energetics, environment, defense and basic sciences. All these are correlated to the new generation of accelerators which, for the acceleration process, may employ electromagnetic fields generated by standard sources, atomic lasers, free electron lasers, Cerenkov effect, Smith - Purcell effect, ...

71

Even Better Mousetraps  

CERN Document Server

First test with new ASACUSA trap show promise for future antihydrogen beam experiments.

2007-01-01

72

Review of High Gain FELs  

Science.gov (United States)

For understanding on basic radiation mechanism of the high-gain FEL based on SASE, the author presents electron-crystal interpretation of FEL radiation. In the electron-crystal, electrons are localized at regularly spaced multi-layers, which represents micro-bunching, whose spacing is equal to the radiation wavelength, and the multi-layers are perpendicular to beam axis, thus, diffracted wave creates Bragg's spots in forward and backward directions. Due to the Doppler's effect, frequency of the back-scattered wave is up-converted, generates forwardly focused X-ray. The Bragg's effect contributes focusing the X-ray beam into a spot, thus peak power becomes extremely higher by factor of typically 107. This is the FEL radiation. As well known, the total numbers of scattered photons in Bragg's spots is equal to the total elastic scattering photons from the atoms contained in the crystal. Therefore, total power in ...

2007-01-19

73

Real-time system for processing regime diagnostic on accelerator  

International Nuclear Information System (INIS)

The automatic real-time system operating at the LU-10 linac and providing measurements of the parameters such as the beam current (average and pulse values), the electron energy, the linear density distribution of beam current, and also the conveyor speed is described in the paper.

74

Recent status of the development of intense ion beams  

Energy Technology Data Exchange (ETDEWEB)

Taking the development of large current, negative ion sources which is in progress aiming at nuclear fusion reactors and the development of high luminance ion sources planned as a part of the Omega Project as the examples, the technology for generating high power ion beams is explained. Both these projects are positioned at the limit of the present technology of high power ion beam application as their targeted beam power reaches several tens MW. Consequently, the requirement for the ion sources is severe, and in particular, the generation of the ion beams having large current density with good convergence is beyond all precedents. The application of high power ion sources has been realized as the neutral beam injectors for large tokamaks. Also the hydrogen negative ion source of large current and the electrostatic acceleration technology for negative ion ...

1993-12-01

75

Coherent Smith-Purcell radiation in the far-infrared region from a short-bunched electron beam  

International Nuclear Information System (INIS)

Coherent Smith-Purcell radiation, emitted from short-bunched electrons passing by a lamellar-type grating of aluminum, has been observed in the millimeter wave region. The energy of the electrons is either 42 MeV when they are accelerated by an L-band linear accelerator or 150 MeV accelerated by an S-band one. The intensity of the radiation is proportional to the square of the beam current. The radiation is linearly polarized, and the electric vector of the radiation is in the plane defined by the observing point and the beam trajectory. The intensity decreases with the beam height, i.e. the distance of the beam from the surface of the grating, in accordance with the modified Bessel function of zeroth order. copyright 1996 American Institute of Physics.

1995-09-28

76

Improved beam confinement in the modified betatron with strong focusing  

International Nuclear Information System (INIS)

The lifetime of the circulating electron beam in the Naval Research Laboratory modified betatron has been increased by more than 2 orders of magnitude with the addition of strong focusing windings to the device. The injected beam consistently spirals from the injector to the minor axis and is trapped. The #approx#0.5-kA trapped electron ring has been accelerated above 10 MeV from the injection energy of 0.5 to 0.6 MeV. The beam acceleration has been confirmed not only by the x-ray attenuation technique but also with the detection of photoneutrons.

77

PBG structures for multi-beam devices  

International Nuclear Information System (INIS)

Photonic band gap structures with single or multiple defects show potential for use in single-beam and multi-beam klystrons and particle accelerators. The primary concerns are the coupling between the modes at each individual defect site and the damping of unwanted higher order modes. A conceptual design of a PBG based, multi-beam klystron and methods to damp HOMs and to cool and tune the structure are presented.

2002-12-12

78

Electromagnetic effects in relativistic electron beam plasma interactions  

Energy Technology Data Exchange (ETDEWEB)

Electromagnetic effects excited by intense relativistic electron beams in plasmas are investigated using a two-dimensional particle code. The simulations with dense beams show large magnetic fields excited by the Weibel instability as well as sizeable electromagnetic radiation over a significant range of frequencies. The possible relevance of beam plasma instabilities to the laser acceleration of particles is briefly discussed. 6 refs., 4 figs.

1985-02-13

79

High-current negative-ion beam transport  

Energy Technology Data Exchange (ETDEWEB)

The requirements for transporting high-current, negative-ion beams are presented with particular emphasis on applications involving negative-hydrogen-ion beams. In addition to the usual matching and steering problems, particular attention must be paid to beam emittance growth in the transport system. Depending on the application, a number of approaches have been developed using both magnetic and electric lenses. I discuss the design considerations for transporting and matching these beams to radiofrequency quadrupole accelerators, and present a survey of the various types of beamlines now used for negative-ion beams.

1993-01-01

80

High-current negative-ion beam transport  

Energy Technology Data Exchange (ETDEWEB)

The requirements for transporting high-current, negative-ion beams are presented with particular emphasis on applications involving negative-hydrogen-ion beams. In addition to the usual matching and steering problems, particular attention must be paid to beam emittance growth in the transport system. Depending on the application, a number of approaches have been developed using both magnetic and electric lenses. I discuss the design considerations for transporting and matching these beams to radio-frequency quadrupole accelerators, and present a survey of the various types of beamlines now used for negative-ion beams.

1992-10-05

81

High-current negative-ion beam transport  

Energy Technology Data Exchange (ETDEWEB)

The requirements for transporting high-current, negative-ion beams are presented with particular emphasis on applications involving negative-hydrogen-ion beams. In addition to the usual matching and steering problems, particular attention must be paid to beam emittance growth in the transport system. Depending on the application, a number of approaches have been developed using both magnetic and electric lenses. I discuss the design considerations for transporting and matching these beams to radiofrequency quadrupole accelerators, and present a survey of the various types of beamlines now used for negative-ion beams.

1993-04-01

82

Design study of longitudinal dynamics of the drive beam in 1 TeV relativistic klystron two-beam accelerator  

International Nuclear Information System (INIS)

In this paper the authors present a design study on the longitudinal dynamics of a relativistic klystron two-beam accelerator (RK-TBA) scheme which has been proposed as a power source candidate for a 1 TeV next linear collider (NLC). They address the issue of maintaining stable power output at desired level for a 300-m long TBA with 150 extraction cavities and present their simulation results to demonstrate that it can be achieved by inductively detuning the extraction cavities to counter the space charge debunching effect on the drive beam. They then carry out simulation study to show that the beam bunches desired by the RK-TBA can be efficiently obtained by first chopping an initially uniform beam of low energy into a train of beam bunches with modest longitudinal dimension and then using the open-quotes adiabatic captureclose quotes scheme to bunch and ...

1994-11-07

83

Assessment of the efficacy of braking radiation beam formation of electron accelerators  

International Nuclear Information System (INIS)

Proceeding from analysis of the influence of parameters of the target-filter system on radiation-physical characteristics of braking radiation, some recommendations were issued for assessment of the forming systems of medical accelerators of electrons. A new criterion - a coefficient of the forming system efficacy - was introduced, characterizing a beam formation tract with relation to a whole set of radiotherapeutic problems.

84

Multi-beamlet focusing of intense negative ion beams by aperture displacement technique  

Energy Technology Data Exchange (ETDEWEB)

Multi-beamlet focusing of an intense negative ion beam has been performed using the beamlet steering by the aperture displacement. The apertures of the grounded grid were displaced as all beamlets of 270 (18 x 15) in the area of 25 cm x 26 cm would be steered to a common point (a focal point) in both the two-stage and the single-stage accelerators. The multi-beamlets were successfully focused and the e-folding half width of 10 cm was achieved 11.2 m downstream from the ion source in both the accelerators. The corresponding gross divergence angle is 9 mrad. The negative ion beamlets are deflected by the magnetic field for the electron deflection at the extraction grid and the deflection direction oppositely changes line by line, resulting in the beam split in the deflection direction. This beamlet deflection was well compensated also using the beamlet steering by the aperture displacement of the grounded ...

1995-08-01

85

Lie Algebraic Treatment of Linear and Nonlinear Beam Dynamics  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this paper is to present a summary of new methods, employing Lie algebraic tools, for characterizing beam dynamics in charged-particle optical systems. These methods are applicable to accelerator design, charged-particle beam transport, electron microscopes, and also light optics. The new methods represent the action of each separate element of a compound optical system, including all departures from paraxial optics, by a certain operator. The operators for the various elements can then be concatenated, following well-defined rules, to obtain a resultant operator that characterizes the entire system. This paper deals mostly with accelerator design and charged-particle beam transport. The application of Lie algebraic methods to light optics and electron microscopes is described elsewhere (1, see also 44). To keep its scope within reasonable bounds, they restrict their ...

1988-12-01

86

Review of ion accelerators  

Energy Technology Data Exchange (ETDEWEB)

The field of ion acceleration to higher energies has grown rapidly in the last years. Many new facilities as well as substantial upgrades of existing facilities have extended the mass and energy range of available beams. Perhaps more significant for the long-term development of the field has been the expansion in the applications of these beams, and the building of facilities dedicated to areas outside of nuclear physics. This review will cover many of these new developments. Emphasis will be placed on accelerators with final energies above 50 MeV/amu. Facilities such as superconducting cyclotrons and storage rings are adequately covered in other review papers, and so will not be covered here.

1990-06-01

87

A report on collective ion acceleration via space charge waves on intense relativistic electron beams  

Science.gov (United States)

Collective methods of ion acceleration using intense relativistic electron beams (IREB) have stimulated a great deal of interest in the past few years. The main virtue of an IREB collective ion accelerator is the high internal electric field strength. The primary drawback has been an insufficient ion energy gain or inadequate scaleability. An extensive study for generating a high quality electron beam has been done and is presented in Section 2. In Section 3 an intense ion injector study was conducted by the method of computer simulation. The last addition to the proposal was a design for producing a toroidal magnetic field. This field will be needed in a future study of high energy and high current electron beams.

1981-02-01

88

Ion sources for initial use at the Holifield radioactive ion beam facility  

Energy Technology Data Exchange (ETDEWEB)

The Holifield Radioactive Ion Beam Facility (HRIBF) now under construction at the Oak Ridge National Laboratory will use the 25-MV tandem accelerator for the acceleration of radioactive ion beams to energies appropriate for research in nuclear physics; negative ion beams are, therefore, required for injection into the tandem accelerator. Because charge exchange is an efficient means for converting initially positive ion beams to negative ion beams, both positive and negative ion sources are viable options for use at the facility; the choice of the type of ion source will depend on the overall efficiency for generating the radioactive species of interest. A high-temperature version of the CERN-ISOLDE positive ion source has been selected and a modified version of the source designed and fabricated for initial use at the ...

1994-12-31

89

Ion sources for initial use at the Holifield Radioactive Ion Beam Facility  

Energy Technology Data Exchange (ETDEWEB)

The Holifield Radioactive Ion Beam Facility (HRIBF) now under construction at the Oak Ridge National Laboratory will use the 25-MV tandem accelerator for the acceleration of radioactive ion beams to energies appropriate for research in nuclear physics; negative ion beams are, therefore, required for injection into the tandem accelerator. Because charge exchange is an efficient means for converting initially positive ion beams to negative ion beams, both positive and negative ion sources are viable options for use at the facility; the choice of the type of ion source will depend on the overall efficiency for generating the radioactive species of interest. A high-temperature version of the CERN-ISOLDE positive ion source has been selected and a modified version of the source designed and fabricated for initial use at the ...

1994-05-01

90

Beam-breakup calculations for the Los Alamos free-electron laser (FEL) linac  

International Nuclear Information System (INIS)

In addition to the usual circularly symmetric TM/sub 010/ mode used to accelerate particles in an rf linac, there is a large number of modes with cos phi or sin phi dependence, for example the TM/sub 1xx/ modes. These latter modes possess a uniform magnetic (dipole) field near the axis of symmetry and therefore can deflect the beam away from the axis. Any portion of an accelerated beam that is off-axis will drive these modes, so that subsequent portions of the beam will be deflected. This deflected beam will then resonantly drive the same modes in downstream cavities, so that still later portions of the beam will be more severely deflected, and so on. In this paper are reported the results of numerical simulations of this so-called cumulative beam-breakup instability. The simulation assumes that only the TM/sub 110/ mode ...

91

Design of a closed 4 MW spallation target module with heat removal system for an ADS system  

International Nuclear Information System (INIS)

At the Forschungszentrum Karlsruhe the HGF Strategy Fund project entitled 'Innovative Technology to Reduce Radiotoxicity' is performed which delivers an essential scientific contribution to the application oriented fundamental research for Accelerator Driven Systems (ADS). The addressed topics are in the areas of heavy liquid metal technology, thermalhydraulics and materials / corrosion. An ADS consists of three main components: an proton accelerator, a spallation target and a subcritical blanket. The strategic objective of an ADS is the transmutation of long-lived radioactive waste (plutonium, minor actinides and long-lived fission products) into short-lived isotopes or stable elements, thus closing the fuel cycle. The objective of one task of the HGF Strategy Fund Project is the numerical calculation of a closed spallation target module. In a consequent next step such a spallation target can be experimentally investigated at IKET and the ...

92

Improved four-stage accel-decel production of low energy highly stripped heavy ions  

Energy Technology Data Exchange (ETDEWEB)

The two model MP Tandem Van de Graaff accelerators at Brookhaven have been used in a four-stage accel-decel configuration to produce highly stripped low energy heavy ions. The performance in this mode of operation has now been substantially improved by modifications of the second accelerator. The inclined field acceleration tube electrodes at the exit of this accelerator were replaced by straight electrodes, the vacuum was improved and the maximum negative terminal potential was increased. Higher intensity beams of heavier highly stripped ions can now be produced at lower energies than before.

1983-04-01

93

Plasma production and flow in negative ion beams  

Science.gov (United States)

Plasma generated in low-density vapor by a negative ion beam has been studied experimentally and computationally. We show that space charge neutralization of the beam occurs at very low vapor density, and that correspondingly the electron density may be much less than the beam and plasma ion densities. When there is a large local gas density, as in a charge changing cell, the resulting high electron density is also localized to the same region. Therefore, very few electrons will reach a negative ion accelerator even if it is placed one or two beam diameters from such a cell.

1977-09-21

94

Longitudinal emittance oscillation in a superconducting drift tube linac  

International Nuclear Information System (INIS)

In drift tube linacs a beam energy spread results form the finite beam size. Radial variation of the axial accelerating field induces a beam energy spread, which, in general, will accumulate as the beam passes through successive drift tubes. This paper shows that under some conditions of periodic transverse focusing and longitudinal phase focusing, the correlation between the longitudinal and transverse motion can be used to correct the energy spread. The process of achieving such a correction is first described in a simplified situation, and then demonstrated for a particular tuning using a ray-tracing program which models a low velocity and low charge state linac designed for radioactive ion beams.

1995-05-01

95

Free-electron laser driven by the LBNL laser-plasma accelerator  

Energy Technology Data Exchange (ETDEWEB)

A design of a compact free-electron laser (FEL), generating ultra-fast, high-peak flux, XUV pulses is presented. The FEL is driven by ahigh-current, 0.5 GeV electron beam from the Lawrence Berkeley National Laboratory (LBNL) laser-plasma accelerator, whose active acceleration length is only a few centimeters. The proposed ultra-fast source (~;;10 fs) would be intrinsically temporally synchronized to the drive laser pulse, enabling pump-probe studies in ultra-fast science. Owing to the high current (>10 kA) of the laser-plasma-accelerated electron beams, saturated output fluxes are potentially greater than 10^13 photons/pulse. Devices based both on self-amplified spontaneous emission and high-harmonic generated input seeds, to reduce undulator length and fluctuations, are considered.

2008-08-04

96

Standing-Wave Free-Electron Laser Two-Beam Accelerator  

Energy Technology Data Exchange (ETDEWEB)

A free-electron laser (FEL) two-beam accelerator (TBA) is proposed, in which the FEL interaction takes place in a series of drive cavities, rather than in a waveguide. Each drive cavity is 'beat-coupled' to a section of the accelerating structure. This standing-wave TBA is investigated theoretically and numerically, with analyses included of microwave extraction, growth of the FEL signal through saturation, equilibrium longitudinal beam dynamics following saturation, and sensitivity of the microwave amplitude and phase to errors in current and energy. It is found that phase errors due to current jitter are substantially reduced from previous versions of the TBA. Analytic scalings and numerical simulations are used to obtain an illustrative TBA parameter set.

1991-02-01

97

Polarized electron sources  

Energy Technology Data Exchange (ETDEWEB)

Polarized electron sources for high energy accelerators took a significant step forward with the introduction of a new laser-driven photocathode source for the SLC in 1992. With an electron beam polarization of >80% and with {approximately}99% uptime during continuous operation, this source is a key factor in the success of the current SLC high-energy physics program. The SLC source performance is used to illustrate both the capabilities and the limitations of solid-state sources. The beam requirements for future colliders are similar to that of the SLC with the addition in most cases of multiple-bunch operation. A design for the next generation accelerator source that can improve the operational characteristics and at least minimize some of the inherent limitations of present sources is presented. Finally, the possibilities for producing highly polarized electron beams for ...

1995-05-01

98

An Experimental Apparatus Proposed for Efficient Removal of Isobaric Contaminants in Negative Ion Beams  

Energy Technology Data Exchange (ETDEWEB)

Isobaric contaminants are often problematical in accelerated negative ion beams for research at certain radioactive ion beam (RIB) and accelerator mass spectrometry (AMS) facilities since their presence in low-intensity rare isotopic beams seriously compromise experimental results. This article describes a non-resonant, laser-based photo-detachment apparatus for use at these facilities, which, according to calculations efficiently removes isobaric contaminants from these beams. The advantage of the system for isobaric contaminant removal over other systems proposed to date lies in its ability to efficiently capture easily transportable energetic negative ion beams with low, intermediate or high energy spreads by a superconducting solenoid magnetic field. The ability to change the diameter of captured beams by adjusting ...

2008-09-01

99

Works on the start-up of an infrared free-electron laser in FIAN  

International Nuclear Information System (INIS)

The description and results of the study on the free-electron laser (FEL) on 100 #mu#m, representing the first line of the FIAN multipurpose radiation complex, are presented. The electron beam with the energy of 6-8 MeV, once accelerated in a racetrack microtron and extracted into the FEL injection tract, is used for exciting this FEL. The system of the electron beam transport, injection and diagnostics are described. Additional works on increasing the beam emittance up to 0.4 A for one energy spread percent are carried out. The obtained electron beam parameters assure generation of the far infrared radiation in the FEL

2000-10-17

100

Heavy-ion linear induction accelerators as drivers for inertial fusion power plants  

Energy Technology Data Exchange (ETDEWEB)

A linear induction accelerator that produces a beam of energetic heavy ions (T -- 10 GeV, A -- 200 amu) is a prime candidate as a driver for an inertial fusion power plant. Some early perceptions were that heavy-ion drive fusion would not be cost-competitive with other power sources because of the high cost of the accelerators. However, improved understanding of the physics of heavy-ion transport and acceleration (supported by experimental results), combined with advances in accelerator technology, have resulted in accelerator design costs -- 50% of previous estimates. As a result, heavy-ion drive fusion power plants are now projected to be cost-competitive with other conceptual fusion power plants. A brief formulation of transport and acceleration physics is presented here, along with a description of the induction Linac cost optimization ...

1988-02-01

101

Heavy-ion linear induction accelerators as drivers for inertial fusion power plants  

International Nuclear Information System (INIS)

A linear induction accelerator that produces a beam of energetic heavy ions (T #approx =# 10 GeV, A #approx =# 200 am#mu#) is a prime candidate as a driver for an inertial fusion power plant. Some early perceptions were that heavy-ion driven fusion would not be cost-competitive with other power sources because of the high cost of the accelerators. However, improved understanding of the physics of heavy-ion transport and acceleration (supported by experimental results), combined with advances in accelerator technology, have resulted in accelerator design costs -- 50% of previous estimates. As a result, heavy-ion driven fusion power plants conceptual fusion power plants. A brief formulation of transport and acceleration physics is presented here, along with a description of the induction Linac cost optimization code LIACEP. Cost trends are ...

102

The Linac Cooherent Light Source (LCLS) Accelerator  

Energy Technology Data Exchange (ETDEWEB)

The Linac Coherent Light Source (LCLS) is a SASE x-ray Free-Electron Laser (FEL) based on the final kilometer of the Stanford Linear Accelerator. Such an FEL requires a high energy, high brightness electron beam to drive the FEL instability to saturation. When fed by an RF-photocathode gun, and modified to include two bunch compressor chicanes, the SLAC linac will provide such a high quality beam at 14 GeV and 1-{micro}m normalized emittance. In this paper, we report on recent linac studies, including beam stability and tolerances, longitudinal and transverse feedback systems, conventional and time-resolved diagnostics, and beam collimation systems. Construction and installation of the injector through first bunch compressor will be completed by December 2006, and electron commissioning is scheduled to begin in January of 2007.

2007-03-21

103

Linac automated beam phase control system.  

Energy Technology Data Exchange (ETDEWEB)

Adjustment of the rf phase in a linear accelerator is crucial for maintaining optimal performance. If phasing is incorrect, the beam will in general have an energy error and increased energy spread. While an energy error can be readily detected and corrected using position readings from beam position monitors at dispersion locations, this is not helpful for correcting energy spread in a system with many possible phase errors. Uncorrected energy spread results in poor capture efficiency in downstream accelerators, such as the Advanced Photon Source's (APS's) particle accumulator ring (PAR) or booster synchrotron. To address this issue, APS has implemented beam-to-rf phase detectors in the linac, along with software for automatic correction of phase errors. We discuss the design, implementation, and performance of these detectors and how they improved APS top-up ...

2006-01-01

104

Conceptual design of industrial free electron laser using superconducting accelerator  

International Nuclear Information System (INIS)

Paper presents conceptual design of free electron laser (FEL) complex for industrial applications. The FEL complex consists of three. FEL oscillators with the optical output spanning the infrared (IR) and ultraviolet (UV) wave-lengths (#lambda# = 0.3...20 #mu#m) and with the average output power 10 - 20 kW. The driving beam for the FELs is produced by a superconducting accelerator. The electron beam is transported to the FELs via three beam lines (125 MeV and 2 x 250 MeV). Peculiar feature of the proposed complex is a high efficiency of the. FEL oscillators, up to 20 %. This becomes possible due to the use of quasi-continuous electron beam and the use of the time-dependent undulator tapering.

1995-08-21

105

The two-beam accelertor  

Energy Technology Data Exchange (ETDEWEB)

The Two-Beam Accelerator (TBA) consists of a long high-gradient accelerator structure (HGS) adjacent to an equal-length Free Electron Laser (FEL). In the FEL, a beam propagates through a long series of undulators. At regular intervals, waveguides couple microwave power out of the FEL into the HGS. To replenish energy given up by the FEL beam to the microwave field induction accelerator units are placed periodically along the length or the FEL. In this manner it is expected to achieve gradients of more than 250 MV/m and thus have serious option for a 1 TeV /times/ 1 TeV linear collider. The state of present theoretical understanding of the TBA is presented with particular emphasis upon operation of the ''steady-state'' FEL, phase and amplitude control of the rf wave, and suppression of sideband instabilities. Experimental work ...

1987-08-01

106

Field emission dark current of technical metallic electrodes  

International Nuclear Information System (INIS)

In the framework of the Low Emittance Gun (LEG) project, high gradient acceleration of a low emittance electron beam will be necessary. In order to achieve this acceleration, a -500 kV, 250 ns FWHM, pulse will be applied between two electrodes. Those electrodes should sustain the pulsed field without arcing, must not outgas and must not emit electrons. Ion back bombardment, and dark current will be damaging to the electron source as well as for the low emittance beam. Electrodes of commercially available OFE copper, aluminium, stainless steel (SS), titanium and molybdenum were tested, following different procedures including plasma glow discharge cleaning.

2007-04-21

107

The LLNL computer control system  

Energy Technology Data Exchange (ETDEWEB)

Lawrence Livermore National Laboratory (LLNL) has implemented a computer control system for operation of an FN tandem accelerator. The control software utilized is the Thaumaturgic Automated Control Logic (TACL) written by the Continuous Electron Beam Accelerator Facility and co-developed with LLNL. Details of the design philosophy, hardware configuration, control software, and special control algorithms will be presented. 2 refs., 4 figs.

1991-10-03

108

Particle acceleration by stimulated emission of radiation near a solid-state active medium  

British Library Electronic Table of Contents (United Kingdom)

We report acceleration of electrons moving in free space near an active Nd:YAG slab. The power of a non-relativistic beam of electrons has increased by more than 30% when the medium was excited. It is demonstrated experimentally that the energy gained by the electrons is linearly proportional to the energy stored in the medium. Moreover, the energy gain traces closely the population inversion inferred by monitoring the spontaneous radiation.

2011-01-01

109

High-brightness photoemitter development for electron accelerator injectors  

Energy Technology Data Exchange (ETDEWEB)

Free-electron-laser (FEL) oscillators require a train of high-brightness bunches. Conventional subharmonic bunchers are currently used with rf linacs to generate pulse trains, but the resulting dilution of the transverse phase space and lower beam brightness are unacceptable for high-performance FELs. Recent developments suggest that photoemitters of high quantum efficiency combined with rapid acceleration can produce pulse trains of higher brightness than has been achieved before.

1985-01-01

110

Brazing techniques for side-coupled electron accelerator structures  

Energy Technology Data Exchange (ETDEWEB)

The collaboration between the Los Alamos National Laboratory and the National Bureau of Standards (NBS), started in 1979, has led to the development of an advanced c-w microtron accelerator design. The four 2380-MHz NBS accelerating structures, containing a total of 184 accelerating cavities, have been fabricated and delivered. New fabrication methods, coupled with refinements of hydrogen-furnace brazing techniques described in this paper, allow efficient production of side-coupled structures. Success with the NBS RTM led to Los Alamos efforts on similar 2450-MHz accelerators for the microtron accelerator operated by the Nuclear Physics Department of the University of Illinois. Two accelerators (each with 17 cavities) have been fabricated; in 1986, a 45-cavity accelerator is being fabricated by private industry with some assistance from Los ...

1986-01-01

111

BNL Neutral Beam Development Group. Progress report, FY 1983 and final report  

Energy Technology Data Exchange (ETDEWEB)

The BNL Neutral Beam Development Group has been active in the program for the development of high energy, high power neutral beam systems since 1973. These injectors are based on the production, acceleration and neutralization of negative hydrogen or deuterium ions and are supposed to be used for plasma heating and current drive in the next generation of fusion devices. Over the span of 10 years the group has studied plasma-surface type of negative hydrogen ion sources, transport and acceleration of negative ion beams and neutralization of negative ions in gases and plasmas. As the required source parameters (current, pulse length, efficiency) were changing over this period of time, the group developed several types of sources, resulting finally in the design of a steady state device operating with an excellent gas efficiency and having the possibility of scaling-up to the size ...

1984-03-16

112

Measurement of the mean energy of the off-axis incident electron without the beam guide. Using a scintillating fiber beam-energy monitor for electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

In the case of total skin electron therapy without the beam guide, the electron beam is scattered just outside the gantry exit, dose uniformity in the field is broken, and dose is spread outside the light field. The aims of this study were to measure the mean energy of the off-axis incident electron beam without the beam guide and to establish a reference for the clinical situation. For the measurement, a 4 MeV electron beam was selected among several energies from the linear accelerator. A scintillating fiber beam energy monitor measured the mean energy of the incident electron beam. This energy monitor is a small, light-weight piece of equipment composed of a wedge absorber, scintillation fiber, and photodiode. We found the relationship between electron energy and the indicated value of the energy monitor by means of ...

2002-06-01

113

Initiation of conformal radiotherapy with a multileaf-collimator - An approach to clinical routine  

International Nuclear Information System (INIS)

The implementation of a three-dimensional conformal radiotherapy facility in the radiotherapy department of the Heinrich Heine University is described. Complex radiotherapy techniques with commercially available networked systems are introduced to improve clinical work. Over 18 month we have gained clinical experience with a PHILIPS Multileaf Collimator (MLC) mounted on a SL 25 linear accelerator. For a limited period the MLC was used as a conventional blocking device. The standard MLC-shapes are controlled with a stand-alone computer system. In addition, a three-dimensional treatment planning system (3-D-TPS / TMS-Radix, Helax AB) based on convolution/superposition algorithms was recently installed. Treatment optimization is achieved using static field arrangements with complete volumetric computerized tomographic patient data for 3-D-TPS. Conformal adaptation of the 95%-isodose to the Planning Target Volume (PTV, ICRU 50) results in ...

1995-10-01

114

Use of the WNR spallation neutron source at LAMPF to determine the absolute efficiency of a neutron scintillation detector  

Energy Technology Data Exchange (ETDEWEB)

Prompt fission neutron spectrum measurements at the University of Massachusetts Lowell 5.5 MV Van de Graaff accelerator laboratory require that the neutron detector efficiency be well known over a neutron energy range of 100 keV to 20 MeV. The efficiency of the detector, has been determined for energies greater than 5.0 MeV using the Weapons Neutron Research (WNR) white neutron source at the Los Alamos Meson Physics Facility (LAMPF) in a pulsed beam, time-of-flight (TOF) experiment. Carbon matched polyethylene and graphite scatterers were used to obtain a hydrogen spectrum. The detector efficiency was determined using the well known H(n,n) scattering cross section. Results are compared to the detector efficiency calculation program SCINFUL available from the Radiation Shielding Information Center at Oak Ridge National Laboratory.

1994-06-01

115

Synchrotron resource of the Howard Hughes Medical Institute  

Energy Technology Data Exchange (ETDEWEB)

The Synchrotron Resource of the Howard Hughes Medical Institute will be dedicated to structural analyses of biological macromolecules, primarily through crystallography. This facility is under construction at the X4 port of the National Synchrotron Light Source at Brookhaven National Laboratory, and it will comprise three beamlines. The first line to be built has been devised to apply the multiwavelength anomalous diffraction method which provides direct estimates for the phases of reflections. The second line will be devoted to rapid and essentially routine diffraction measurements, mainly through the rotation method. These two experimental stations are contained within refrigerated radiation enclosures that will maintain clean environments, narrowly defined constant temperatures, and protection against biohazard at biosafety level BL-2. At the same time as the second line will be developed, the swath center is planned to first serve as a monitor of the white x-ray ...

1989-07-01

116

Study of in-medium $\\omega$ meson properties in Ap, pA and AA collisions  

CERN Document Server

We propose to investigate the in-medium properties of vector $\\omega$ mesons at the normal nuclear density in Ap(pA) collisions and at higher density in AA collisions at the ITEP accelerator facility TWAC. Using of the inverse Ap kinematics will permit us to study the $\\omega$ meson production in a wide momentum interval included the not yet explored range of small meson momenta relative to the projectile nuclei where the mass modification effect in nuclear matter is expected to be the strongest. Momentum dependence of the in-medium $\\omega$ meson width will be studied in the traditional pA kinematics. We intend to use the electromagnetic calorimeter for reconstruction of the $\\omega$ meson invariant mass by detecting photons from the $\\omega \\to \\pi^{0}\\gamma \\to 3\\gamma$ decay. The model calculations and simulations with RQMD generator show feasibility of the proposed experiment. Available now intensity of the ion ...

2008-01-01

117

Development and clinical experience of C-arm type radiosurgery system or three dimensional therapy system  

Energy Technology Data Exchange (ETDEWEB)

Authors developed a C-arm type radiosurgery system of the linear accelerator suitable for stereotactic radiation therapy and a software for arranging 3-dimensional therapy in the system. In this system, the gantry far conical irradiation of 4 MV (0.6-3 Gy/min) and 6 MV (0.9-4.5 Gy/min) X ray or electron beam for the therapy was connected to a newly designed C-arm and was made capable of rotating around either of the axes crossing vertically. With this system, it became unnecessary to move the bed table of the patient for getting suitable distribution of radiation dose. The local accuracy which was measured by the CCD videocamera on the gantry, was within 0.5 mm from the radiation center. The system made it possible to shorten the irradiation time and to improve the local accuracy of irradiating site. The clinical trial was begun from June, 1996. (K.H.)

1996-10-01

118

Construction of the ATLAS end cap electromagnetic calorimeter and study of its performances; Construction du bouchon du calorimetre electromagnetique d'ATLAS et etudes de ses performances  

Energy Technology Data Exchange (ETDEWEB)

ATLAS is one of the four experiments which will take place at the LHC, the CERN future protons collider. This accelerator, which should start in 2007, will allow to continue the studies carried out by its predecessors, as the standard model Higgs boson and new physics searches. The very high luminosity -10 fb{sup -1} during the first three functioning years, then 100 fb{sup -1}- and the 14 TeV in the frame center will ease these studies. The Centre de Physique des Particules de Marseille took part in the ATLAS collaboration, taking in charge half of the End-cap electromagnetic calorimeter modules construction. The description of this sub-detector and the construction steps, in particular the electrical tests which allow the stacking validation, are presented in this document. These tests results, obtained for the live first production modules, are analysed. The pre-series module (module 0) performances, obtained with beam ...

2002-09-01

119

Focusing atomic beams by the dissipative radiation-pressure force of laser light  

Science.gov (United States)

An experimental realization of the focusing of an atomic beam by a spontaneous radiation pressure force is reported. A simple light field configuration for focusing an atomic beam is described which is formed by four divergent Gaussian laser beams propagating along the + or - x and + or - y directions of a Cartesian coordinate system. An experimental arrangement for the laser focusing is shown, and the experimental procedure is described. The resulting atomic beam profiles are shown and discussed. It is concluded that the experiments open up the possibility of gaining control over such parameters of atomic beams as their density and divergence. 7 references.

1986-02-01

120

Compact Dielectric Wall Accelerator Development For Intensity Modulated Proton Therapy And Homeland Security Applications  

Energy Technology Data Exchange (ETDEWEB)

Compact dielectric wall (DWA) accelerator technology is being developed at the Lawrence Livermore National Laboratory. The DWA accelerator uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. Its high electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The DWA concept can be applied to accelerate charge particle beams with any charge to mass ratio and energy. Based on the DWA system, a novel compact proton therapy accelerator is being developed. This proton therapy system will produce individual pulses that can be varied in intensity, energy and spot width. The system will be capable of being sited in a conventional linac vault and provide intensity modulated rotational therapy. The status of the ...

2009-06-17

121

Long pulse production of high current D"- ion beams in the JT-60 negative ion source  

International Nuclear Information System (INIS)

The first long pulse production of high power D"- ion beams has been demonstrated in the JT-60 U negative ion sources, each of which was designed to produce 22 A, 500 keV D"- ion beams. Voltage holding capability and the grid power loading were examined for long pulse production of high power D"- ion beams. From the correlation between voltage holding and the light intensity of cathodoluminescence from the Fiber Reinforced Plastic insulators, the acceleration voltage for stable voltage holding capability was found to be less than 320-340 kV where the light was sufficiently suppressed. By tuning the extraction voltage, the grid power loadings in the ion sources were decreased to the allowable levels for long pulse injection without a significant reduction of the beam power. After tuning the acceleration and extraction voltages, D"- ion beams ...

2008-02-01

122

The NuMI proton beam at Fermilab successes and challenges  

Energy Technology Data Exchange (ETDEWEB)

The NuMI beam at Fermilab has delivered over 5 x 10{sup 20} 120 GeV protons to the neutrino production target since the start for MINOS [1] neutrino oscillation experiment operation in 2005. We report on proton beam commissioning and operation status, including successes and challenges with this beam.

2008-11-01

123

Summary and closing remarks  

Energy Technology Data Exchange (ETDEWEB)

A summary of the topics covered in papers presented at the 1995 Brookhaven joint conference on production, neutralization, and application of negative ion beams is given. The conference topics covered included plasma ion sources, plasma seeding of these sources for increased ion production, beam extraction and transport, computer simulation and design studies, and operation of existing and experimental ion source facilities. Application of the sources to accelerator, tokamak, and thin film deposition are discussed. (AIP) {copyright} {ital 1996 American Institute of Physics.}

1996-07-01

124

JAS'2000  

CERN Multimedia

Are you interested in beam dynamics? Do you work on the LHC injectors or CLIC or maybe feasibility studies fornew machines? Then this is for youJAS'2000: Joint CERN-Japan-JINR-Russia-US SchoolFrontiers of Accelerator Technology: High Quality Beams to be held on a river boat between St. Petersburg and Moscow 1 to 14 July 2000. For further information see eitherhttp://schools.web.cern.ch/Schools/CAS/ orhttp://www.indiana.edu/~uspas/programs/js/jas2000.html

2000-01-01

125

High gain 10.6-micron free-electron laser amplifier  

International Nuclear Information System (INIS)

A 10.6-micron wavelength free-electron laser (FEL) amplifier has been operated using a 45-MeV, 600-A electron beam from the Advanced Test Accelerator (ATA) and a 15.36-meter long electromagnetic wiggler. The peak small signal power gain was 27 dB(500). Gain guiding was observed to confine the amplified laser beam.

1988-11-02

126

Progress of negative-ion based NBI system for JT-60U  

Energy Technology Data Exchange (ETDEWEB)

The operation of the negative ion based NBI system for JT-60U has been progressed since 1996. Most of the efforts in the operation for increasing beam power and energy have been concentrated to get over the troubles, caused by surge energy at the moment of the accelerator break-down, in the ion sources and high voltage power supplies. The ion source for the N-NBI, so far, has accelerated negative ion beams of 14.3 A at 380 keV with deuterium and 18.5 A at 360 keV with hydrogen against the target of 22 A. The neutral beam power injected into JT-60U has already reached 5.2 MW at 350 keV for 0.7 sec with deuterium. (author)

1998-07-01

127

Physical properties of wood-polyester composites prepared by an electron beam accelerator  

Energy Technology Data Exchange (ETDEWEB)

Polyester WPC (wood-polymer composite) systems are one of the promising materials for multiple uses increasing the mechanical properties, provided that their dimensional stability can be improved. Possibility was pursued for the improvement in the dimensional stability of the polyester WPC systems prepared by electron beam irradiation. The impregnation of the mixture of polyester and monomer into both oven-dried beech veneers and preswollen wood was followed by mutual irradiation process. Polymerization was carried out at total dosage of 6 Mrad to the respective surfaces of samples by an electron beam accelerator, and the reaction was completed by heating at 80 deg C for 24 hr. The dimensions of the samples were measured primarily in the tangential direction, and their dynamic modulus and loss modulus were measured by a Rheovibron DDV-2 and the vibrating reed method. The results and the discussion are given for the reaction ...

1981-01-01

128

Physical properties of wood-polyester composites prepared by an electron beam accelerator  

International Nuclear Information System (INIS)

Polyester WPC (wood-polymer composite) systems are one of the promising materials for multiple uses increasing the mechanical properties, provided that their dimensional stability can be improved. Possibility was pursued for the improvement in the dimensional stability of the polyester WPC systems prepared by electron beam irradiation. The impregnation of the mixture of polyester and monomer into both oven-dried beech veneers and preswollen wood was followed by mutual irradiation process. Polymerization was carried out at total dosage of 6 Mrad to the respective surfaces of samples by an electron beam accelerator, and the reaction was completed by heating at 80 deg C for 24 hr. The dimensions of the samples were measured primarily in the tangential direction, and their dynamic modulus and loss modulus were measured by a Rheovibron DDV-2 and the vibrating reed method. The results and the discussion are given for the reaction ...

1980-09-01

129

Fast Beam Intensity Measurements for the LHC  

CERN Document Server

Particle accelerators are constructed and operated for a wide variety of applications. In particle physics - the branch of physics that studies the elementary constituents of matter and forces between them - high energy accelerators are used to look deep into the structure of matter. Medical particle accelerators are used for example in medicine to treat tumours [31], in imaging techniques such as Positron Emission Tomography (PET) [24], or for the radio-isotopes production. They also serve in many other industrial branches, e.g. geology, radiocarbon dating [39], molecular complex spectroscopy, lithography, food preservation etc. The eld of accelerator technology draws knowledge and expertise from a wide range of scientic disciplines and uses the latest technical knowledge. The incomplete list of covered disciplines includes mathematics, physics, electronics, computing, electromagnetic eld technology, ...

2010-01-01

130

Ion beam pulsing for time of flight (TOF) experiments  

Energy Technology Data Exchange (ETDEWEB)

The essential mechanical and electronic parts of a beam pulsing system are described, which reaches an energy resolution of ..delta..E/E=0.1%-0.4% in the energy range from 100 eV and 10 keV.

1985-01-01

131

Total skin electron beam therapy in mycosis fungoides. Evaluation of a technique for deceleration of electron beam energy and clinical study  

Energy Technology Data Exchange (ETDEWEB)

The studies using phantoms confirmed that the reduction of electron beam energy and minimization of X-ray contamination could be achieved when electron beam was interposed by an acrylic plate placed 20 cm anterior to a patient. Four patients of mycosis fungoides were treated with 8 MeV electron beam of a linear accelerator at UOEH Hospital from October 1981 to December 1986. Two of them were treated with this technique by placing 2 cm thick acrylic plate anterior to the patients and satisfactory results were obtained. Cutaneous lesions subsided remarkably with the dosage of 2000 cGy given in 2 months. Leucopenia due to bone marrow suppression was mild and the patients tolerated the treatment well.

1988-08-01

132

Relative luminosity measurement of the LHC with the ATLAS forward calorimeter  

CERN Document Server

In this paper it is shown that a measurement of the relative luminosity changes at the LHC may be obtained by analysing the currents drawn from the high voltage power supplies of the electromagnetic section of the forward calorimeter of the ATLAS detector. The method was verified with a reproduction of a small section of the ATLAS forward calorimeter using proton beams of known beam energies and variable intensities at the U-70 accelerator at IHEP in Protvino, Russia. The experimental setup and the data taking during a test beam run in April 2008 are described in detail. A comparison of the measured high voltage currents with reference measurements from beam intensity monitors shows a linear dependence on the beam intensity. The non-linearities are measured to be less than 0.5 % combining statistical and systematic uncertainties.

2010-01-01

133

Focused ion beam system  

Energy Technology Data Exchange (ETDEWEB)

A focused ion beam (FIB) system produces a final beam spot size down to 0.1 .mu.m or less and an ion beam output current on the order of microamps. The FIB system increases ion source brightness by properly configuring the first (plasma) and second (extraction) electrodes. The first electrode is configured to have a high aperture diameter to electrode thickness aspect ratio. Additional accelerator and focusing electrodes are used to produce the final beam. As few as five electrodes can be used, providing a very compact FIB system with a length down to only 20 mm. Multibeamlet arrangements with a single ion source can be produced to increase throughput. The FIB system can be used for nanolithography and doping applications for fabrication of semiconductor devices with minimum feature sizes of 0.1 .mu.m or less.

1999-01-01

134

Focused ion beam system  

Energy Technology Data Exchange (ETDEWEB)

A focused ion beam (FIB) system produces a final beam spot size down to 0.1 {mu}m or less and an ion beam output current on the order of microamps. The FIB system increases ion source brightness by properly configuring the first (plasma) and second (extraction) electrodes. The first electrode is configured to have a high aperture diameter to electrode thickness aspect ratio. Additional accelerator and focusing electrodes are used to produce the final beam. As few as five electrodes can be used, providing a very compact FIB system with a length down to only 20 mm. Multibeamlet arrangements with a single ion source can be produced to increase throughput. The FIB system can be used for nanolithography and doping applications for fabrication of semiconductor devices with minimum feature sizes of 0.1 m or less. 13 figs.

1999-08-31

135

Collisional Cooling of Negative Ion Beams  

Science.gov (United States)

Investigations have been conducted to determine the feasibility of using collisional cooling for reducing the energy spreads and, consequently, the emittances of negative-ion beams. We have designed a gas-filled RF-quadrupole ion cooler equipped with provisions for retarding energetic negative ion beams to energies below thresholds for electron detachment at injection and for re-acceleration to high energies after the cooling process. The device has been used to cool O{sup -} and F{sup -} ion beams with initial energy spreads, {Delta}E > 10 eV to final energy spreads, {Delta}E {approx} 2 eV FWHM. Overall transmission efficiencies of {approx}14% for F{sup -} beams have been obtained. Experimental results show that electron detachment is the major loss mechanism for negative ions.

2001-06-29

136

Collisional Cooling of Negative Ion Beams  

Energy Technology Data Exchange (ETDEWEB)

Investigations have been conducted to determine the feasibility of using collisional cooling for reducing the energy spreads and, consequently, the emittances of negative-ion beams. We have designed a gas-filled RF-quadrupole ion cooler equipped with provisions for retarding energetic negative ion beams to energies below thresholds for electron detachment at injection and for re-acceleration to high energies after the cooling process. The device has been used to cool O{sup -} and F{sup -} ion beams with initial energy spreads, {Delta}E > 10 eV to final energy spreads, {Delta}E {approx} 2 eV FWHM. Overall transmission efficiencies of {approx}14% for F{sup -} beams have been obtained. Experimental results show that electron detachment is the major loss mechanism for negative ions.

2001-06-29

137

Initial electron-beam characterizations for the Los Alamos APEX Facility  

Energy Technology Data Exchange (ETDEWEB)

The ongoing upgrade of the Los Alamos Free-Electron Laser (FEL) Facility involves the addition of a photoelectric injector (PEI) and acceleration capability to about 40 MeV. The electron-beam and high-speed diagnostics provide key measurements of charge, beam position and profile, divergence emittance, energy (centroid, spread, slew, and extraction efficiency), micropulse duration, and phase stability. Preliminary results on the facility include optical transition radiation interferometer measurements of divergence (1 to 2 mrad), FEL extraction efficiency (0.6 {plus minus} 0.2%), and drive laser phase stability (< 2 ps (rms)). 10 refs.

1991-01-01

138

Initial electron-beam characterizations for the Los Alamos APEX Facility  

Energy Technology Data Exchange (ETDEWEB)

The ongoing upgrade of the Los Alamos Free-Electron Laser (FEL) Facility involves the addition of a photoelectric injector (PEI) and acceleration capability to about 40 MeV. The electron-beam and high-speed diagnostics provide key measurements of charge, beam position and profile, divergence emittance, energy (centroid, spread, slew, and extraction efficiency), micropulse duration, and phase stability. Preliminary results on the facility include optical transition radiation interferometer measurements of divergence (1 to 2 mrad), FEL extraction efficiency (0.6 {plus_minus} 0.2%), and drive laser phase stability (< 2 ps [rms]). 10 refs.

1991-12-31

139

Progress at LAMPF, 1992--1993  

Energy Technology Data Exchange (ETDEWEB)

This Progress Report describes the operation of the Los Alamos Meson Physics Facility (LAMPF) and the research programs carried out there for the years 1992 and 1993. The accelerator operated for over 100 days in 1992, providing beams of H{sup +}, H{sup {minus}}, and polarized H{sup {minus}} for a rich and varied research program in nuclear physics. The accelerator had only fair beam availability in 1992 (for example, the average H{sup +} beam availability was 72%), caused largely by problems in the 201-MHz rf system. A major effort was expended to address these problems before the 1993 run. These efforts were rewarded by good beam availability in 1993 and few problems with the 201-MHz system. LAMPF operated remarkably smoothly during 1993, in the midst of a period of great uncertainty in the future of the facility and the downsizing of MP Division, which led to ...

1994-07-25

140

Elise plans and progress  

International Nuclear Information System (INIS)

Elise is a heavy ion induction linear accelerator that will demonstrate beam manipulations required in a driver for inertial fusion energy. With a line charge density similar to that of heavy ion drivers, Elise will accelerate a #>=# 1 gs beam pulse of K"+ ions from an initial energy of 2 MeV to a final energy #>=# 5 MeV. In the present design, the Elise electrostatic quadrupoles (ESQ) will have a 2.33 cm radius aperture operating at #+-#59 kV. The half-lattice periods range from 21 cm to 31 cm. The entire machine will be approximately 30 m long, half of that is the induction accelerator and the remaining half is the injector (including the Marx generator) and the matching section. Elise will be built in a way that allows future expansion into the full ILSE configuration, therefore it will have an array of four ESQ focusing channels capable of transporting up to a total of 3.2 ...

1995-09-06

141

Distributed Grating-Assisted Coupler for Optical All-Dielectric Electron Accelerator  

Energy Technology Data Exchange (ETDEWEB)

A Bragg waveguide consisting of multiple dielectric layers with alternating index of refraction becomes an excellent option to form electron accelerating structure powered by high power laser sources. It provides confinement of a synchronous speed-of-light mode with extremely low loss. However, laser field can not be coupled into the structure collinearly with the electron beam. There are three requirements in designing input coupler for a Bragg electron accelerator: side-coupling, selective mode excitation, and high coupling efficiency. We present a side coupling scheme using a distributed grating-assisted coupler to inject the laser power into the waveguide. Side coupling is achieved by a grating with a period on the order of an optical wavelength. The phase matching condition results in resonance coupling thus providing selective mode excitation capability. The coupling efficiency is limited by profile matching between ...

2005-09-23

142

Analysis of the beam bunching produced by a free electron laser  

International Nuclear Information System (INIS)

A high-power microwave Free Electron Laser (FEL) experiment has been performed to study the inherent electron beam bunching that occurs in the FEL interaction. An induction linac delivered a 1 kA, 2.2 MeV electron beam to a FEL amplifier. In the process of amplifying the input signal of frequency 35 GHz to power levels of the order of 10 MW, the electron beam was bunched by the ponderomotive force. In this paper we describe the FEL experiment and the optical technique that was used to observe the bunches. Their properties as functions of the basic FEL parameters are discussed. copyright 1996 American Institute of Physics.

143

The pisa experiment: spallation products identified by bragg curve spectroscopy  

International Nuclear Information System (INIS)

In the framework of spallation neutron sources and accelerator-driven systems, the international PISA (Proton-induced Spallation) collaboration has initiated measurements of total- and double-differential cross-sections for products of spallation reactions in a wide range of target nuclei (GU) at the COSY proton accelerator in Julich (Germany). The purpose is to study secondary particle production created in structural, window and target materials via proton beams up to 2.5 GeV of incident kinetic energy. Residual nuclei [H, He up to intermediate mass fragment (IMF)] production cross-sections are of great importance for estimating the damage to target and structure materials involving the planned spallation neutron sources, given that the lifetime of window and target materials is directly associated to those cross-sections. The demand for reliable theoretical predictions on production cross-sections is by no means ...

2004-05-17

144

Selection and design of ion sources for use at the Holifield radioactive ion beam facility  

Energy Technology Data Exchange (ETDEWEB)

The Holifield Radioactive Ion Beam Facility now under construction at the Oak Ridge National Laboratory will use the 25 MV tandem accelerator for the acceleration of radioactive ion beams to energies appropriate for research in nuclear physics; negative ion beams are, therefore, required for injection into the tandem accelerator. Because charge exchange is an efficient means for converting initially positive ion beams to negative ion beams, both positive and negative ion sources are viable options for use at the facility. The choice of the type of ion source will depend on the overall efficiency for generating the radioactive species of interest. Although direct-extraction negative ion sources are clearly desirable, the ion formation efficiencies are often too low for practical consideration; for this situation, positive ...

1994-06-01

145

Minimal Neutrino Beta Beam for Large theta_13  

CERN Document Server

We discuss the minimum requirements for a neutrino beta beam if theta_13 is discovered by an upcoming reactor experiment, such as Double Chooz or Daya Bay. We require that both neutrino mass hierarchy and leptonic CP violation can be measured to competitive precisions with a single-baseline experiment in the entire remaining theta_13 range. We find that for very high isotope production rates, such as they might be possible using a production ring, a (B,Li) beta beam with a gamma as low as 60 could already be sufficient to perform all of these measurements. If only the often used nominal source luminosities can be achieved, for example, a (Ne,He) beta beam from Fermilab to a possibly existing water Cherenkov detector at Homestake with gamma \\sim 190-350 (depending on the Double Chooz best-fit) could outperform practically any other beam technology including ...

2008-01-01

146

The 0.9 MW proton beam at PSI and studies on a 10 MW cyclotron  

Energy Technology Data Exchange (ETDEWEB)

The conceptual design for a cyclotron that could possibly deliver a 10 MW proton beam, presented at the previous ADTT conference, is discussed in comparison with the operational experience gained with 0.9 MW beam power in the upgraded cyclotron facility at PSI that has reached the design goal of 1.5 mA at 590 MeV in 1995. Some critical aspects of the design are e.g. RF power and beam loading, beam loss and activation, space charge effects and bunching. 12 refs., 2 figs., 1 tab.

1997-09-01

147

Polarizing a stored proton beam by spin flip?  

International Nuclear Information System (INIS)

We discuss polarizing a proton beam in a storage ring, either by selective removal or by spin flip of the stored ions. Prompted by recent, conflicting calculations, we have carried out a measurement of the spin-flip cross section in low-energy electron-proton scattering. The experiment uses the cooling electron beam at COSY as an electron target. The measured cross sections are too small for making spin flip a viable tool in polarizing a stored beam. This invalidates a recent proposal to use co-moving polarized positrons to polarize a stored antiproton beam.

2009-04-27

148

In-beam #gamma#-ray spectroscopy of fast beams at the NSCL  

International Nuclear Information System (INIS)

With the development of an array of highly-segmented germanium detectors, it now becomes possible to perform in-flight #gamma#-ray spectroscopy experiments on intermediate energy beams with unprecedented #gamma#-ray energy resolution. Presented in this report are examples of two techniques in which SeGA, the most highly-segmented operational germanium array for in-flight spectroscopy with fast beams, was used for the detection of #gamma# rays. SeGA used in conjunction with a high-resolution magnetic spectrograph (S800) to detect the reaction residues in coincidence represents a powerful combination for in-beam #gamma#-ray studies.

2004-04-05

149

Design of electron beam accelerators for microwave application  

Energy Technology Data Exchange (ETDEWEB)

Relativistic electron beams are used for generating high power microwaves. These microwave sources require electron beam generators spanning significant ranges in voltage and impedance. The pulsed power technology used to generate these electron beams is presented. Electron beam generators that produce beams with pulse durations in the 10-ns to 100-ns regime consist of an energy-storage section, pulse-shaping section, and an electron beam diode. The energy-storage section is either a Marx generator or capacitor bank-pulsed transformer. The pulse shaping is done with high-voltage transmission lines. The electron beam diode is usually a cold-cathode, space-charge-limited flow device. For longer pulses (/approximately/1 ..mu..s) the energy storage and pulse chaping can be combined. Lumped-element pulse-forming networks (PFN) can be designed to ...

1988-07-01

150

Design of electron beam accelerator for microwave application  

Energy Technology Data Exchange (ETDEWEB)

Relativistic electron beams are used for generating high power microwaves. These microwave sources require electron beam generators spanning significant ranges in voltage and impedance. The pulsed power technology used to generate these electron beams is presented. Electron beam generators that produce beams with pulse durations in the 10 ns to 100 ns regime consist of an energy storage section, pulse shaping section, and an electron beam diode. The energy storage section is either a Marx generator or capacitor bank-pulsed transformer. The pulse shaping is done with high-voltage transmission lines. The electron beam diode is usually a cold-cathode, space-charge-limited flow device. For longer pulses (approx.1 ..mu..s) the energy storage and pulse shaping can be combined. Lumped-element pulsed-forming networks (PFN) can be designed to produce ...

1988-01-01

151

Production, transport and injection of a cold non-magnetized electron beam for the recirculating linac  

International Nuclear Information System (INIS)

A new foilless diode with a non-magnetically immersed cathode was recently designed and built for the Sandia Recirculating Linear Accelerator (RLA). Because there is also no radial component of electric field at the cathode, the electron beam starts almost parallel and is matched to a solenoidal transport system with minimum increase in divergence and radius. The electrode emission surface is specified by an area covered with felt which undergoes explosive electron emission at low electrical field stresses (60 kV/cm). The 1.7 MV, 4.8-kA produced beam is transported 1.5 meters to the injection region of the racetrack via a system of solenoids and focusing coils. The maximum transverse velocity component at injection point (1.5 m downstream from the cathode surface) is #beta# perpendicular = 0.03 and the radius r = 2.8 cm which give a quite small beam emittance #epsilon# = 0.08 rad-cm. Three- dimensional ...

1989-06-01

152

Negative ion source electrode  

Energy Technology Data Exchange (ETDEWEB)

The present invention concerns a negative ion source electrode which can be preferably used in a neutral particle injection device using negative ions for a thermonuclear reactor. Negative ion beams are deflected to the direction opposite to the deflecting direction by magnetic fields by using an electron suppression electrode having electrode holes with the position previously displaced before negative ion beams are accelerated to have a high energy by an accelerator thereby correcting the orbit of the negative ion beams easily. In addition, since the deflection correction electrode having the electrode holes is disposed, a proper voltage is applied to the deflection correction electrode to correct the orbit of the negative ion beams conveniently. Since the deflection correction electrode has a simple structure of a thin flat plate having electrode holes, the ...

1997-01-17

153

AECL IMPELA electron beam industrial irradiators  

International Nuclear Information System (INIS)

A family of industrial irradiators is being developed by AECL to cover an electron-beam energy range from 5 to 18 MeV at beam powers between 20 and 250 kW. The IMPELA family of irradiators is designed for push button, reliable operation. The major irradiator components are modular, allowing for later upgrades to meet increased demands in either electron or X-ray mode. Interface between the control system, irradiator availability and dose quality assurance is in conformance with the most demanding specifications. The IMPELA irradiators use a klystron-driven, standing-wave, L-band accelerator structure with direct injection from a rugged, triode electron gun. Direct control of the accelerating field during the beam pulse ensures constant output beam energy, independent of beam power. The first member of the family, the IMPELA 10/50 (10 MeV, 50 ...

154

Hydrogen flame acceleration and transition to detonation  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the results obtained from two large experimental facilities built at Sandia National Laboratories in Albuquerque, NM. FLAME (Flame Acceleration Measurements and Experiments) is a large horizontal rectangular channel designed to study flame acceleration, transition to detonation, simulation of combustion in containment geometries, component heating, and other problems in hydrogen combustion relevant to reactor safety. The Heated Detonation Tube has been designed to study detonations in hydrogen-air-steam mixtures. Both facilities have been in operation for just over a year. 12 figures.

1984-01-01

155

Hydrogen flame acceleration and transition to detonation  

International Nuclear Information System (INIS)

This paper describes the results obtained from two large experimental facilities built at Sandia National Laboratories in Albuquerque, NM. FLAME (Flame Acceleration Measurements and Experiments) is a large horizontal rectangular channel designed to study flame acceleration, transition to detonation, simulation of combustion in containment geometries, component heating, and other problems in hydrogen combustion relevant to reactor safety. The Heated Detonation Tube has been designed to study detonations in hydrogen-air-steam mixtures. Both facilities have been in operation for just over a year. 12 figures.

1984-10-23

156

Dosimetry measurements of x-ray and neutron radiation levels near the shuttle and end beam dump at the advanced test accelerator: Beam Research Program  

International Nuclear Information System (INIS)

Electron beams as a source of directed energy are under study at the Lawrence Livermore National Laboratory (LLNL). An intense 10-kA, 50-MeV, 50-ns full-width half-maximum, pulsed electron beam is generated by the prototype Advanced Test Accelerator (ATA) at the Laboratory's Site 300. Whenever the electron beam is stopped in materials, intense radiation is generated. Estimates based on available data in the literature show that for materials such as lead, photon radiation (x ray, gamma, bremsstrahlung) levels can be as large as 10"4 roentgens per pulse at 1 m in the zero-degree direction (i.e., the electron-beam direction). Neutrons, which are emitted isotropically, are produced at a level of 10"1"3 n/m"2 per pulse. Depending upon the number of pulses and the shielding geometry, the accumulated dose is potentially lethal to personnel and potentially damaging to instrumentation that ...

157

The Fermilab Linac Upgrade  

Energy Technology Data Exchange (ETDEWEB)

The Fermilab Linac Upgrade is planned to increase the energy of the H- linac from 200 to 400 MeV. This is intended to reduce the incoherent space-charge tuneshift at injection into the 8 GeV Booster which can limit either the brightness or the total intensity of the beam. The Linac Upgrade will be achieved by replacing the last four 201.25 MHz drift-tube tanks which accelerate the beam from 116 to 200 MeV, with seven 805 MHz side-coupled cavity modules operating at an average axial field of abut 7.5 MV/m. This will allow acceleration to 400 MeV in the existing Linac enclosure. Each accelerator module will be driven with a klystron-based rf power supply. A prototype rf modulator has been built and tested at Fermilab, and a prototype 12 MW klystron is being fabricated by Litton Electron Devices. Fabrication of production accelerator modules is in progress. 8 ...

1991-02-01

158

The Darmstadt near-infrared free-electron laser  

International Nuclear Information System (INIS)

The salient features of the near-infrared free-electron laser (FEL) that is under construction at the new Darmstadt superconducting 130-MeV electron accelerator are discussed. Special attention is given to the layout and the parameters of the accelerator, the layout of the planned FEL experiment, the characteristics of the electron gun, the subharmonic chopper-buncher system, and the hybrid undulator system of the Darmstadt FEL. A comparison of the planned Darmstadt FEL with conventional lasers, with respect to the pulse and wavelength region, is presented. 15 refs.

1989-04-24

159

Early Experience in Using an 18 MeV Linear Accelerator for Mycosis Fungoides at Howard University Hospital  

UK PubMed Central (United Kingdom)

This paper describes the problems and solutions in using 18 MeV linear accelerator, with minimum 6 MeV electron capability, for total skin irradiation for mycosis fungoides. The 6 MeV electron energy...Full Text Available

1977-04-01

160

Computer modeling of two-phase flow  

Science.gov (United States)

The accelerating flow of a lighter continuous phase through a heavier one is considered. Small nonuniformities grow into large ones due to the Rayleigh-Taylor instability. An experiment exemplifying the large bubble formation due to Rayleigh-Taylor instability was performed and simulated using the PHOENICS 84 computer code. The same numerical procedure was applied to the two-phase flow in a gun barrel. It shows that the acceleration provided by the movement of the projectile can cause initial nonuniformities to grow with time.

1986-10-01

161

Total skin electron beam therapy in mycosis fungoides  

International Nuclear Information System (INIS)

The studies using phantoms confirmed that the reduction of electron beam energy and minimization of X-ray contamination could be achieved when electron beam was interposed by an acrylic plate placed 20 cm anterior to a patient. Four patients of mycosis fungoides were treated with 8 MeV electron beam of a linear accelerator at UOEH Hospital from October 1981 to December 1986. Two of them were treated with this technique by placing 2 cm thick acrylic plate anterior to the patients and satisfactory results were obtained. Cutaneous lesions subsided remarkably with the dosage of 2000 cGy given in 2 months. Leucopenia due to bone marrow suppression was mild and the patients tolerated the treatment well. (author).

162

Explosives detector  

Energy Technology Data Exchange (ETDEWEB)

An apparatus for non-invasively inspecting an object, such as an item of luggage, for explosives material is described. It comprises a multi-channel thermal neutron inspection system having a plurality of neutron irradiation chambers. Simultaneous operation of several channels increases the maximum system throughput several times. Each chamber has a lithium neutron source which is stimulated to neutron production by a proton beam. Beam switching magnets are energised by pulsing to divert a common proton beam to each source in turn. The initial beam is generated by a radio frequency quadrupole accelerator. The advantages of this system are very low residual source activity and controllable neutron production thereby minimising safety hazards. The irradiation chamber may contain several different gamma ray detectors to identify the elements present in explosives material. In addition, ...

1991-10-02

163

The compact linear collider CLIC  

CERN Document Server

A high luminosity (10e34 - 10e35 cm square/s) electron-positron Collider (CLIC) with a nominal centre-of-mass energy of 3 TeV has been under study for a number of years at CERN within an international collaboration of laboratories and institutes to provide the HEP community with a new accelerator-based facility for the post-LHC era. In order to achieve the very high design luminosity, very low emittance beams have to be produced and focused down to very small beam sizes at the interaction point. Beam acceleration using high frequency normal-conducting structures operating at high accelerating fields significantly reduces the length and, in consequence, the cost of the linac. The overall length of the 3 TeV collider is about 33 km. The goals of the CLIC scheme are ambitious, and require further R&D to demonstrate that they are indeed technically feasible. A ...

2004-01-01

164

Free electron laser and accelerator  

International Nuclear Information System (INIS)

The present report addresses several aspects of the free electron laser (FEL) and accelerator, including their features, potentials, mechanisms, beams emitted from undulator, FEL produced by helical mangnetic field, major problems with FEL, etc. In FEL, relativistic electron beams interact with an electromagnetic field with periodically changing intensity to produce coherent electromagnetic waves with variable wavelength. The capability of varying its wavelength represents the greatest advantage over conventional lasers. Any periodic magnetic field can serve as a wiggler. A wiggler can be used both in an amplifier and oscillator. A periodic magnetic field used may be either of a parallel type or of a helical type. The polarization of emitted beams depends on the shape of the magnet regardless of whether its field is parallel or helical. An equation is derived in the report which expresses the wavelength ...

1988-08-01

165

Recent Darrieus vertical axis wind turbine aerodynamical experiments at Sandia National Laboratories  

Science.gov (United States)

Experiments contributing to the understanding of the aerodynamics of airfoils operating in the vertical axis wind turbine (VAWT) environment are described. These experiments are ultimately intended to reduce VAWT cost of energy and increase system reliability. They include chordwise pressure surveys, circumferential blade acceleration surveys, effects of blade camber, pitch and offset, blade blowing, and use of sections designed specifically for VAWT application.

1981-05-01

166

Status and Challenges of the LHC Construction  

CERN Document Server

The LHC is designed to provide proton beams of 7 TeV and nominal luminosity of 10**34 cm**-2s**-1. This objective is achieved at an affordable cost by pushing all major collider components to the limits of technology, by upgrading the existing CERN accelerators and infrastructure, and by involving the technical expertise, resources and dedication of accelerator laboratories world-wide. Following a decade of intensive R&D and technical validation of major collider systems, the LHC construction is now fully underway. Major industrial contracts have been awarded and are in execution for the procurement of the magnet, cryogenics and other systems. In this report, the status of the design and construction of the major LHC systems is presented.

2001-01-01

167

PARALLEL 3-D SPACE CHARGE CALCULATIONS IN THE UNIFIED ACCELERATOR LIBRARY.  

Energy Technology Data Exchange (ETDEWEB)

The paper presents the integration of the SIMBAD space charge module in the UAL framework. SIMBAD is a Particle-in-Cell (PIC) code. Its 3-D Parallel approach features an optimized load balancing scheme based on a genetic algorithm. The UAL framework enhances the SIMBAD standalone version with the interactive ROOT-based analysis environment and an open catalog of accelerator algorithms. The composite package addresses complex high intensity beam dynamics and has been developed as part of the FAIR SIS 100 project.

2006-06-26

168

Noninvariance of space/time-scale ranges under a Lorentz transformation and the implications for the study of relativistic interactions  

International Nuclear Information System (INIS)

The summary of this report is: (1) The range of scales #LAMBDA# of a system is not a Lorentz invariant and can vary greatly for some systems. (2) There exists an optimum frame which minimizes #LAMBDA#. (3) We demonstrated speedup of x1000 for PIC simulation of relativistic beam interacting with electron background. (4) It is not in contradiction with the conventional scientific wisdom that 'complexity' is an invariant. (5) We identified three domains of application (laser-plasma acceleration, e-cloud in HEP accelerators, free electron lasers) for which speedup ranging from 2 to 4 orders of magnitude were demonstrated on toy problems.

169

Injection and extraction magnets: septa  

CERN Document Server

An accelerator has limited dynamic range: a chain of accelerators is required to reach high energy. A combination of septa and kicker magnets is frequently used to inject and extract beam from each stage. The kicker magnets typically produce rectangular field pulses with fast rise- and/or fall-times, however the field strength is relatively low. To compensate for their relatively low field strength, the kicker magnets are generally combined with electromagnetic septa. The septa provide relatively strong field strength but are either DC or slow pulsed. This paper discusses injection and extraction systems with particular emphasis on the hardware required for the septa.

2010-01-01

170

Comprehensive, nonintercepting electron-beam diagnostics using spontaneous emission  

Energy Technology Data Exchange (ETDEWEB)

Characterization and optimization of electron-beam parameters are important aspects of optimizing free-electron laser (FEL) performance. The visible spontaneous emission ({lambda}{approximately}650 nm) from the 5-meter long undulator of the Boeing FEL experiment can be characterized in sufficient detail with a streak/spectrometer to deduce time-resolved electron-beam spatial position and profile, micropulse duration, and energy. 7 refs., 13 figs., 2 tabs.

1989-01-01

171

Status of the Lawrence Berkeley Laboratory and Lawrence Livermore National Laboratory free electron laser (FEL)  

Energy Technology Data Exchange (ETDEWEB)

A description of the FEL experiment underway at the 10 kA, 5 MeV Experimental Test Accelerator (ETA) is described. The facility has been designed to investigate the high-gain operation of an FEL.

1983-09-19

172

Free electron laser  

International Nuclear Information System (INIS)

Physics and technology of free electron laser (FEL) are reviewed. Mechanisms of stimulated emission in FEL and its present status and future prospects are presented. Electromagnetic wiggler, two stage FEL and so on are also interpreted. Finally, accelerators and wigglers for FEL, recent FEL experiments and FEL applications are noted. (author).

173

Accelerated interleaflet transport of phosphatidylcholine molecules in membranes under deformation.  

UK PubMed Central (United Kingdom)

Biological membranes are lamellar structures composed of two leaflets capable of supporting different mechanical stresses. Stress differences between leaflets were generated during micromechanical experiments...Full Text Available

1996-09-01

174

Two-gigawatt burst-mode operation of the intense microwave prototype (IMP) free-electron laser (FEL) for the microwave tokamak experiment (MTX)  

Energy Technology Data Exchange (ETDEWEB)

The MTX explored the plasma heating effects of 140 GHz microwaves from both Gyrotrons and from the IMP FEL wiggler. The Gyrotron was long pulse length (0.5 seconds maximum) and the FEL produced short-pulse length, high-peak power, single and burst modes of 140 GHZ microwaves. Full-power operations of the IMP FEL wiggler were commenced in April of 1992 and continued into October of 1992. The Experimental Test Accelerator H (ETA-II) provided a 50-nanosecond, 6-MeV, 2--3 kAmp electron beam that was introduced co-linear into the IMP FEL with a 140 GHz Gyrotron master oscillator (MO). The FEL was able to amplify the MO signal from approximately 7 kW to peaks consistently in the range of 1--2 GW. This microwave pulse was transmitted into the MTX and allowed the exploration of the linear and non-linear effects of short pulse, intense power in the MTX plasma. Single pulses were used to explore and gain operating experience in the ...

1993-10-06

175

Proposal for a free electron laser driven by the 7 MeV NILPRP linac  

International Nuclear Information System (INIS)

The proposal made in this paper refers to a free electron laser FEL with small-period electromagnet undulator in SASE regime and a FEL transverse optical klystron in the amplifier regime. The relativistic electron beam source for this FEL is the 7 MeV electron linac of the National Institute for Laser, Plasma and Physics Radiation (NILPRP) in Bucharest. The paper presents the main features of the design and performance of both FELs and discusses the improvements which must be made to the accelerator in order to use it as a free electron source concerning the injection system of electrons and formation of accelerated electron beam. The findings show that this FEL can be employed as a coherent radiation source in the IR range. (author)

176

Los Alamos Advanced Free-Electron Laser  

Energy Technology Data Exchange (ETDEWEB)

At Los Alamos, we are building a free-electron laser (FEL) for industrial, medical, and research applications. This FEL, which will incorporate many of the new technologies developed over the last decade, will be compact in size, robust, and user-friendly. Electrons produced by a photocathode will be accelerated to 20 MeV by a high-brightness accelerator and transported using permanent-magnet quadrupoles and dipoles. They will form an electron beam with an excellent instantaneous beam quality of 10 {pi} mm mrad in transverse emittance and 0.3% in energy spread at a peak current up to 300 A. Including operation at higher harmonics, the laser wavelength extends form 3.7 {mu}m to 0.4 {mu}m. In this paper, we will describe the project and the programs to date. 10 refs., 10 figs., 1 tab.

1991-01-01

177

Developments of linacs for ADTT in the USA  

Energy Technology Data Exchange (ETDEWEB)

Interesting developments in linear accelerators have been attained over the past 45 years. The status of linear accelerators and future possibilities are described in context of demanding applications and technology maturity. Features of industrial or `factory`-type applications are high availability, economic operations, low investment cost and ease of running a facility. All features have been demonstrated in one manner or another at large operating facilities for the research community; within a different context that has been argued in the past to be not as demanding as for `factory` installation. In addition, comments are made relative to intense beam power levels and choices that can be made for power levels below 10 MW, on the assumption that a cw beam is required. 1 fig., 1 tab.

1997-09-01

178

Characteristics of the 18 MeV medical linear accelerator 'NELAC-1018', 2. Electron beams  

Energy Technology Data Exchange (ETDEWEB)

The performance and characteristics of a medical linear accelerator ''NELAC-1018'' for the electron beam therapy were discussed. Measurement of deep dose distribution revealed that the 80% range was 1.9 cm by 6 MeV, 2.8 cm by 9 MeV, 3.9 cm by 12 MeV, 4.9 cm by 15 MeV and 5.5 cm by 18 MeV. Iso-dose distribution with each tubus and cone showed a favorable flatness by any of the energies. The degree of flatness was extremely favorable, being +-1.7% or less.

1983-11-01

179

Measurements of K-beta/K-alpha X-ray intensity ratios using VEC beams  

International Nuclear Information System (INIS)

An experiment on the K#beta#/K#alpha# characteristic X-ray intensity ratio in silver was performed at VEC Centre, Calcutta using the #alpha#-beams at energies 40 MeV and 50 MeV employing a Si(Li) detector system on-line. The results show that the K#beta#/K#alpha# X-ray intensity ratio at energies 40 and 50 MeV are 0.215 #+-# 0.006 and 0.216 #+-# 0.006, respectively, which indicates no change with beam energy and in accordance with the earlier reports. The present experiment shows the feasibility of studying the K#beta#/K#alpha# ratios as a function of beam energy in different regions of periodic table. Experiments in elements belonging to the 3d shell and their compounds are suggested to look for the chemical effects and their dependence on #alpha#-energy. (author). 7 refs.

1987-02-03

180

The Multipoles Factory An Element of the LHC Control  

CERN Document Server

The measurements performed at CERN on prototypes and first pre-series main dipole magnets confirm the need of an active control of the Large Hadron Collider to compensate the dynamic field changes during the proton beam injection and acceleration. This control requires in turn an accurate forecast of the magnetic field in the accelerator. We plan to predict the field on the basis of two elements: theoretical field models tailored through the accumulated knowledge of the main magnets during series tests, and an on-line measurement system running on few reference magnets tracking the LHC current cycle. Data coming from this "Multipoles Factory" will result from the fusion of the two sources. Based on this system we foresee to deliver calibration information for pre-defined accelerator cycles as well as real time information for the active control. In this paper we report the conceptual design of the ...

2002-01-01

181

State-of-the-Art developments in accelerator controls at the APS.  

Energy Technology Data Exchange (ETDEWEB)

The performance requirements of the Advanced Photon Source (APS) challenge the control system in a number of areas. This paper will review a few applications of advanced technology in the control and monitoring of the APS. The application of digital signal processors (DSPs) and techniques will be discussed, both from the perspective of a large distributed multiprocessor system and from that of embedded systems. In particular, two embedded applications will be highlighted, a beam position monitor processor and a DSP-based power supply controller. Fast data distribution is often a requirement. The application of a high-speed network based on reflective memory will also be discussed in the context of the APS global orbit feedback system. Timing systems provide opportunities to apply technologies such as high-speed logic and fiber optics. Examples of the use of these technologies will also be included. Finally, every modern accelerator control ...

1999-04-13

182

Selected topics in particle accelerators: Proceedings of the CAP meetings. Volume 5  

Energy Technology Data Exchange (ETDEWEB)

This Report includes copies of transparencies and notes from the presentations made at the Center for Accelerator Physics at Brookhaven National Laboratory Editing and changes to the authors` contributions in this Report were made only to fulfill the publication requirements. This volume includes notes and transparencies on nine presentations: ``The Energy Exchange and Efficiency Consideration in Klystrons``, ``Some Properties of Microwave RF Sources for Future Colliders + Overview of Microwave Generation Activity at the University of Maryland``, ``Field Quality Improvements in Superconducting Magnets for RHIC``, ``Hadronic B-Physics``, ``Spiking Pulses from Free Electron Lasers: Observations and Computational Models``, ``Crystalline Beams in Circular Accelerators``, ``Accumulator Ring for AGS & Recent AGS Performance``, ``RHIC Project Machine Status``, and ``Gamma-Gamma Colliders.``

1995-10-01

183

Linac Coherent Light Source Longitudinal Feedback Model  

Energy Technology Data Exchange (ETDEWEB)

The Linac Coherent Light Source (LCLS) will be the world's first x-ray free-electron laser (FEL). To ensure the vitality of FEL lasing, it is critical to preserve the high quality of the electron beam during acceleration and compression. The peak current and final energy are very sensitive to system jitter. To minimize this sensitivity, a longitudinal feedback system on the bunch length and energy is required, together with other diagnostics and feedback systems (e.g., on transverse phase space). Here, we describe a simulation framework, which includes a realistic jitter model for the LCLS accelerator system, the RF acceleration, structure wakefield, and second order optics. Simulation results show that to meet the tight requirements set by the FEL, such a longitudinal feedback system is mandatory.

2005-06-15

184

Electron-beam-plasma ion source as source of negative fluorine  

Energy Technology Data Exchange (ETDEWEB)

Radioactive ion beams (RIBs) of short-lived isotopes of fluorine are in demand for investigating astrophysical phenomena related to the hot CNO cycle and rp processes responsible for stellar nucleosynthesis. Since negative ion beams are required for injection into tandem electrostatic accelerators, such as the 25 MV tandem accelerator used for post acceleration of RIBs for the Holifield Radioactive Ion Beam Facility (HRIBF) research program at the Oak Ridge National Laboratory (ORNL), efficient, direct-formation F{sup -} ion sources are highly desirable for RIB applications involving this type of post-accelerator. We have conceived and evaluated a direct extraction F{sup -} source for potential RIB applications which is predicated on the reverse polarity operation of a positive electron-beam-plasma target/ion source ...

1997-11-01

185

Programmed improvements of the alternating gradient synchrotron complex at Brookhaven National Laboratory, Upton, New York. Environmental assessment  

Energy Technology Data Exchange (ETDEWEB)

The purpose and need for DOE to undertake the actions described in this document are to improve the efficiency of the Alternating Gradient Synchrotron (AGS) complex. Benefits would include optimization of the AGS scientific program, increased high-energy and nuclear physics experimentation, improved health and safety conditions for workers and users, reduced impact on the environment and the general public, energy conservation, decreased generation of hazardous and radioactive wastes, and completion of actions required to permit the AGS to be the injector to the Relativistic Heavy Ion Collider (RHIC)., Improved efficiency is defined as increasing the AGS`s capabilities to capture and accelerate the proton intensity transferred to the AGS from the AGS booster. Improved capture of beam intensity would reduce the beam losses which equate to lost scientific opportunity for study and increased potential for radiation doses to ...

1994-03-01

186

Intense negative-ion beams extracted from an ECR ion source coupled to a charge exchange canal  

Energy Technology Data Exchange (ETDEWEB)

Electron cyclotron resonance (ECR) ion sources possess several advantages over ion sources conventionally used for injectors of electrostatic accelerators: improved reliability, high efficiency, simplicity, and the capability of generating bright, high-current ion beams. We have adapted a high-current ECR source originally developed as an injector for a CW RFQ proton linac to serve as a source of intense negative-ion beams for the Tandem Accelerator Superconducting Cyclotron (TASCC) facility at Chalk River. The range of ion species of the source has been extended from H{sup 1+} alone up to Bi{sup 1+}, with both gaseous and nonvolatile feeds. Two intense negative-ion beams of He{sup -} and O{sup -} have been generated so far with the source coupled to a standard charge-exchange canal. We foresee no major problems generating a broad range of negative ions with this system. (author)

1993-07-01

187

Intense negative-ion beams extracted from an ECR ion source coupled to a charge exchange canal  

International Nuclear Information System (INIS)

Electron cyclotron resonance (ECR) ion sources possess several advantages over ion sources conventionally used for injectors of electrostatic accelerators: improved reliability, high efficiency, simplicity, and the capability of generating bright, high-current ion beams. We have adapted a high-current ECR source originally developed as an injector for a CW RFQ proton linac to serve as a source of intense negative-ion beams for the Tandem Accelerator Superconducting Cyclotron (TASCC) facility at Chalk River. The range of ion species of the source has been extended from H1+ alone up to Bi1+, with both gaseous and nonvolatile feeds. Two intense negative-ion beams of He- and O- have been generated so far with the source coupled to a standard charge-exchange canal. We foresee no major problems generating a broad range of negative ions with this system. (author)

1993-09-22

188

Dosimetric properties of an applicator system for intraoperative electron-beam therapy utilizing a Clinac--18 accelerator  

International Nuclear Information System (INIS)

A prototype electron applicator system providing circular and rectangular fields for use in intraoperative electron beam therapy with a Varian Clinac 18 linear accelerator has been fabricated. The dosimetric properties of this system for a variety of electron-beam energies, applicator sizes, and x-ray collimator settings was documented. Significant findings include: (a) surface dose values are in excess of 90% for electron energies of 12 MeV and above; (b) for the 18-MeV beam, the deepest depth where the central axis dose is 90% of its maximum value is in excess of 50 mm for circular applicators whose diameters are in excess of 5 cm; and (c) the treatment time to deliver 1000 rads ''given dose'' (at a given dose rate of 300 MU/min) is on the order of 3--4 min. Cross-field behavior is acceptable for the intended application and x-ray contamination is less than 4% for any applicator/electron energy ...

189

Characterization of an add-on multileaf collimator for electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

An add-on multileaf collimator for electrons (eMLC) has been developed that provides computer-controlled beam collimation and isocentric dose delivery. The design parameters result from the design study by Gauer et al (2006 Phys. Med. Biol. 51 5987-6003) and were configured such that a compact and light-weight eMLC with motorized leaves can be industrially manufactured and stably mounted on a conventional linear accelerator. In the present study, the efficiency of an initial computer-controlled prototype was examined according to the design goals and the performance of energy- and intensity-modulated treatment techniques. This study concentrates on the attachment and gantry stability as well as the dosimetric characteristics of central-axis and off-axis dose, field size dependence, collimator scatter, field abutment, radiation leakage and the setting of the accelerator jaws. To provide isocentric irradiation, the eMLC can ...

2008-02-21

190

Stability against temperature variations at the ALS  

Energy Technology Data Exchange (ETDEWEB)

We have studied the effects of temperature fluctuations on the Advanced Light Source (ALS). By modeling the storage ring support structure, we find that fluctuations of {plus minus}2 to 3deg C in the tunnel will cause photon beam motion of the order of the beam size. Temperature stabilization at this level will allow the residual motion of the photon beams to be reduced by a second level of active feedback, operating on signals from photon beam position monitors. Air temperature in the experimental area and the temperature of cooling water serving the beamlines should be constant to {plus minus}1deg C. This will provide a suitable environment for experiments. (orig.).

1990-05-20

191

In-beam spectroscopy of nuclei  

International Nuclear Information System (INIS)

The main features and advantages of a new low energy nuclear spectroscopic method, the in-beam spectroscopy are described. Results of in-beam spectroscopic experiments performed at the Institute of Nuclear Research (ATOMKI, Debrecen, Hungary) are summarized. Gamma spectra of in-beam produced odd-odd nuclei were measured, gamma-energies were determined. Measurement of gamma-gamma coincidences led to the construction of energy level schemes of the investigated nuclei. Internal conversion electron spectroscopy was used to determine the multipolarities of transitions. A few spectra and level schemes are presented to illustrate the review. Theoretical interpretation of experimental results are briefly summarized. (D.Gy.).

1982-01-01

192

Operating experience with a new accelerator control system based upon microprocessors  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the design and operating experience with a high performance control system tailored to the requirements of the SuperHILAC accelerator. A large number (20) of the latest 16-bit microcomputer boards are used in a parallel-distributed manner to get a high system bandwidth. Because of the high bandwidth, software costs and complexity are significantly reduced. The system by its very nature and design is easily upgraded and repaired. Dynamically assigned and labeled knobs, together with touch-panels, allow a flexible and efficient operator interface. An X-Y vector graphics system provides for display and labeling of real-time signals as well as general plotting functions. This control system allows attachment of a powerful auxiliary computer for scientific processing with access to accelerator parameters.

1981-03-01

193

Multi-GeV electron spectrometer  

Energy Technology Data Exchange (ETDEWEB)

The advance in laser-plasma acceleration techniques pushes the regime of the resulting accelerated particles to higher energies and intensities. In particular the upcoming experiments with the FLAME laser at LNF will enter the GeV regime with almost 1nC of electrons. From the current status of understanding of the acceleration mechanism, relatively large angular and energy spreads are expected. There is therefore the need to develop a device capable to measure the energy of electrons over three orders of magnitude (few MeV to few GeV) under still unknown angular divergences. Within the PlasmonX experiment at LNF a spectrometer is being constructed to perform these measurements. It is made of an electro-magnet and a screen made of scintillating fibers for the measurement of the trajectories of the particles. The large range of operation, the huge number of particles and the need to ...

2010-11-11

194

Future Accelerators, Muon Colliders, and Neutrino Factories  

Energy Technology Data Exchange (ETDEWEB)

Particle physics is driven by five great topics. Neutrino oscillations and masses are now at the fore. The standard model with extensions to supersymmetry and a Higgs to generate mass explains much of the field. The origins of CP violation are not understood. The possibility of extra dimensions has raised tantalizing new questions. A fifth topic lurking in the background is the possibility of something totally different. Many of the questions raised by these topics require powerful new accelerators. It is not an overstatement to say that for some of the issues, the accelerator is almost the experiment. Indeed some of the questions require machines beyond our present capability. As this volume attests, there are parts of the particle physics program that have been significantly advanced without the use of accelerators such as the subject of neutrino oscillations and many aspects of the particle-cosmology ...

2001-12-19

195

A thermal hydraulic investigation on ADSR liquid lead target  

Energy Technology Data Exchange (ETDEWEB)

Computational fluid dynamics(CFD) code FLUENT was used to simulate the thermal hydraulic processes occurring in conceptual design of the accelerator-driven subcritical reactor(ADSR) liquid lead target. The purpose of the analysis is to investigate the thermal hydraulic characteristics of liquid lead as ADSR target material with various target geometries and injection locations of proton beam. In the calculation analysis, the local temperature of the liquid lead target rises to the boiling temperature very rapidly. When the proton beam is injected from the bottom of the target system, the duration time to reach the boiling temperature is longer and the temperature distribution is flatter than other cases.

1998-05-01

196

Simulation of a Standing-Wave Free-Electron Laser  

Energy Technology Data Exchange (ETDEWEB)

The standing-wave free-electron laser (FEL) differs from a conventional linear-wiggler microwave FEL in using irises along the wiggler to form a series of standing-wave cavities and in reaccelerating the beam between cavities to maintain the average energy. The device has been proposed for use in a two-beam accelerator (TBA) because microwave power can be extracted more effectively than from a traveling-wave FEL. The standing-wave FEL is modeled in the continuum limit by a set of equations describing the coupling of a one-dimensional beam to a TE{sub 01} rectangular-waveguide mode. Analytic calculations and numerical simulations are used to determine the time variation of the reacceleration field and the prebunching required so that the final microwave energy is the same in all cavities. The microwave energy and phase are found to be insensitive to modest spreads in the beam energy ...

1990-09-01

197

Improved method for producing negative ion beams from the group IIA elements for tandem Van de Graaff applications  

Energy Technology Data Exchange (ETDEWEB)

A brief description of a method for producing relatively intense molecular negative ion beams for the difficult Group IIA elements is given which offers considerable improvement in terms of source operation and beam intensity stability over other methods conventionally utilized. It is particularly suited for use in cesium plasma sources such as the Aarhus geometry and axial geometry versions of the source. The method utilizes H/sub 2/ source feed gas for the production of a hydrogen-rich plasma discharge which sputters a negatively biased probe made of elemental or copper alloy material. Negative ion beams of MgH/sub 3//sup -/>=12 ..mu.. A have been realized during routine operation of the 25 MV tandem accelerator. Negative ion beam intensity data, typical source operational parameters, and examples of mass spectra associated with their production are given. Interesting ...

1983-06-01

198

Development of high power negative ion sources for fusion at JAERI  

Energy Technology Data Exchange (ETDEWEB)

Technologies producing high power negative ion beams have been highly developed in these years at JAERI for use in neutral beam injectors for heating the thermonuclear fusion plasmas. At present, it is possible to produce multi-ampere H-/D- ion beams quasi-continuously at energies more than a few hundred keV with a good beam optics of beamlet divergence of a few milli-radian. Based on these technologies, two R and D projects have been initiated; one is to develop a 22A/500keV/10s D- ion source for the neutral beam injector for JT-60U, and the other is to develop a 1A/1MeV/60s H- ion source to demonstrate high current negative ion acceleration up to the energy of 1MeV, the energy required for the neutral beam injector for International Thermonuclear Experimental Reactor (ITER). (author).

1995-10-01

199

Collisional cooling of negative-ion beams  

Energy Technology Data Exchange (ETDEWEB)

Studies have been conducted to determine the feasibility of using collisional cooling for reducing emittances and energy spreads in negative-ion beams to levels commensurate with effective isobaric purification with conventional high-resolution electromagnetic isobar separators as required for use at the Holifield Radioactive Ion Beam Facility (HRIBF). We have designed a gas-filled radio frequency quadrupole ion cooler equipped with provisions for retarding energetic negative-ion beams to energies below thresholds for electron detachment at injection and for re-acceleration to initial energies after the cooling process. The device has been used to cool several ion beams with initial energy spreads, {delta}E>10 eV to final energy spreads, {delta}E{approx}2 eV FWHM, including O{sup -} and F{sup -}. Overall transmission efficiencies of {approx}14% for F{sup -} ...

2002-01-01

200

Advances in beam physics and technology: Colliders of the future  

International Nuclear Information System (INIS)

Beams may be viewed as directed and focussed flow of energy and information, carried by particles and electromagnetic radiation fields (ie, photons). Often, they interact with each other (eg, in high energy colliders) or with other forms of matter (eg, in fixed targets, sychrotron radiation, neutron scattering, laser chemistry/physics, medical therapy, etc.). The whole art and science of beams revolve around the fundamental quest for, and ultimate implementation of, mechanisms of production, storage, control and observation of beams -- always directed towards studies of the basic structures and processes of the natural world and various practical applications. Tremendous progress has been made in all aspects of beam physics and technology in the last decades -- nonlinear dynamics, superconducting magnets and rf cavities, beam instrumentation and control, novel concepts and collider ...

1994-11-14

201

High-power, high-brightness pseudospark-produced electron beam driven by improved pulse line accelerator  

Energy Technology Data Exchange (ETDEWEB)

A high power (200KV), intense current density, low emittance (71mmmrad), high brightness (8x10{sup 10}A/m rad) electron beam was generated in the 10cm long, high-voltage-resistive multi-gap hollow cathode pseudospark chamber filled with 15pa nitrogen and driven by an improved pulse line accelerator. The beam was ejected with the 1mm diameter, the 2.2KA beam current, and the 400ns pulse length, and could propagated 20cm in the drift tube. At a distance of 5cm from the anode it penetrated consecutively an acid-sensitive discoloring film and a 0.05mm-thick copper foil both stuck closely, left 0.6mm and 0.3mm holes on them, respectively. That 10 shots on an acid-sensitive film produced a hole of 1.6mm at 7cm downstream of anode showed its good repeatability. After 60 shots the pseudospark discharge chamber was disassembled and observed that almost no destructive damage traces left on the surfaces of its ...

1995-12-31

202

Construction, testing of the 1 MW, 130-260 GHz Fusion-FEM  

Energy Technology Data Exchange (ETDEWEB)

During the previous 9 months the major part of the Fusion-FEM has been constructed. The 2 MV Insulated Core Transformer, the electron gun, the accelerator, the focusing lenses and the undulator have been tested on-site. In the present - temporary - set-up, the electron beam line consists of a 12 A, 80 keV thermionic electron gun, a 2 MeV dc accelerator, beam transport optics, the undulator and a collector. The gun is mounted in the high voltage terminal, which is now at -2 MV, and the undulator and mm-wave system am at ground potential outside the SF{sub 6}-filled pressure tank. This so-called inverse set-up allows easy access to the larger part of the beam line, the undulator and the mm-wave system, which is important in the conditioning phase. The decelerator and depressed collector am not yet installed. The design of the electron beam line has been optimised ...

1995-12-31

203

Theory of low voltage annular beam free-electron lasers  

Energy Technology Data Exchange (ETDEWEB)

An nonlinear analysis of an annular beam propagating through a cylindrical waveguide in the presence of a helical wiggler and an axial guide field is presented. The analysis is based upon the ARACHNE simulation which is a non-wiggler-averaged slow-time-scale simulation code in which the electromagnetic field is represented as a superposition of the TE and TM modes in a vacuum waveguide, and the beam space-charge waves are represented as a superposition of Gould-Trivelpiece modes. The DC self-electric and self-magnetic fields are also included in the model. ARACHNE has been extensively benchmarked against experiments at MIT and NRL in the past with good agreement, but all of these experiments have dealt with solid electron beams and beam voltages in excess of 200 kV. In seeking to reduce the beam voltage requirements we now consider the ...

1995-12-31

204

(Evaluation of the high intensity plasma sputer negative ion source and to test the response of the University of Tsukuba 13-MV tandem accelerator to mA intensity level pulsed mode heavy negative ion beams)  

Energy Technology Data Exchange (ETDEWEB)

A working visit was made to the National Laboratory for High Energy Physics, Tsukuba, Japan, during the time periods May 16, 1988--June 15, 1988 for the purposes of further evaluation of the high intensity plasma sputter negative ion source and to test the response of the University of Tsukuba 13-MV tandem accelerator to mA intensity level pulsed mode heavy negative ion beams. During the visit, the traveler worked in collaboration with Japanese scientists in installing and testing of the source on the University of Tsukuba tandem electrostatic accelerator injector. During the course of preliminary testing of the ion source and prior to actual injection into the accelerator, sparking began in one or more tube sections, which ultimately led to the decision to replace the damaged tube sections. This problem led to postponement of the scheduled tandem accelerator tests. The traveler ...

1988-07-06

205

PROGRESS IN BEAM FOCUSING AND COMPRESSION FOR WARM-DENSE MATTER EXPERIMENTS  

Energy Technology Data Exchange (ETDEWEB)

The Heavy-Ion Fusion Sciences Virtual National Laboratory is pursuing an approach to target heating experiments in the Warm Dense Matter regime, using spacecharge-dominated ion beams that are simultaneously longitudinally bunched and transversely focused. Longitudinal beam compression by large factors has beendemonstrated in the Neutralized Drift Compression Experiment (NDCX) with controlledramps and forced neutralization. Using an injected 30-mA K+ ion beam with initialkinetic energy 0.3 MeV, axial compression leading to ~;;50-fold current amplification andsimultaneous radial focusing to beam radii of a few mm have led to encouraging energy deposition approaching the intensities required for eV-range target heating experiments. We discuss the status of several improvements to our Neutralized Drift Compression Experiment ...

2008-09-25

206

Study of GaSb+Bi system by proton backscattering method  

International Nuclear Information System (INIS)

The thermal stability of diffusion barriers is explored on the basis of Bi films at different expedients of deriving of films. The examinations were conducted on the electrostatic accelerator at KNU of name Karazin V.N. under conditions of an isothermal bakeout directly under a proton beam of 1,85 MeV energy.

207

Research accomplishments and future goals in particle physics  

Energy Technology Data Exchange (ETDEWEB)

This document presents our proposal to continue the activities of Boston University researchers in eight projects in high energy physics research: Colliding Beams Physics; Accelerator Design Physics; MACRO Project; Proton Decay Project; Theoretical Particle Physics; Muon G-2 Project; and Hadron Collider Physics. The scope of each of these projects is presented in detail in this paper.

1990-01-05

208

Proceedings of the meeting on the technical study at KEK  

International Nuclear Information System (INIS)

Technical studies on constructing the J-PARC (Japan Proton Accelerator Research Complex) are presented by five authors: (1) on the wiring for electromagnets of the 50 GeV synchrotron, (2) on the fast beam-extraction from the 50 GeV synchrotron into two opposite directions, (3) on the target chamber system for the generation of muons, (4) on the design of large aperture electromagnets, and (5) on the maintenance and control of the electromagnet power supplies. (K.Y.)

2006-11-28

209

Principles of photon colliders  

Energy Technology Data Exchange (ETDEWEB)

Future linear colliders offer unique opportunities to study {gamma}{gamma}, {gamma}e interactions. Using the laser backscattering method one can obtain {gamma}{gamma}, {gamma}e colliding beams with energy and luminosity comparable to the electron-position luminosity or even higher. In this review physical principles of photon colliders are described and various problems, concerning the accelerator, laser, interaction region and luminosity are discussed. Some examples of physical processes are given. ((orig.)).

1995-02-01

210

Planning and Operation of Commercial Application Center  

Energy Technology Data Exchange (ETDEWEB)

The objectives of this R and D project are as follows : First, transferring developed technologies to outside companies and operating technology market to vitalize technology transactions, Second, developing commercial application projects to transfer technologies for commercial purposes and to solve interface problems in commercial applications, Third, enhancing commercial utilizations of developed accelerator and beam utilization technologies, Finally. preparing infra-structures for the development of over 30 venture- businesses based on achieved technologies through the Proton Engineering Frontier Project.

2003-06-15

211

Performance of CDF calorimeter simulation for Tevatron Run II  

Energy Technology Data Exchange (ETDEWEB)

The upgraded CDF II detector has collected first data during the initial operation of the Tevatron accelerator in Run II. The simulation of the CDF electromagnetic and hadronic central and upgraded plug (forward) calorimeter is based on the Gflash calorimeter parameterization package used within the GEANT based detector simulation of the Run II CDF detector. We present the results of tuning the central and plug calorimeter response to test beam data.

2002-09-19

212

Operation of the AGS polarized beam  

Energy Technology Data Exchange (ETDEWEB)

A polarized proton physics run took place during January, 1988, at the Brookhaven AGS. It is the purpose of this paper to review the tune-up period preceding that run. This was the third such run at the AGS; the others occurred in June of 1984 and February of 1986. Some comparisons will be drawn among these. A thorough review of the history and hardware associated with the acceleration of polarized protons at the AGS can be found in the proceedings of the last meeting of this group at Protvino and will not be repeated here. 2 refs., 6 figs., 1 tab.

1988-01-01

213

Development of a new secondary beam separator and a new gas-jet target at Kyushu University  

International Nuclear Information System (INIS)

In order to facilitate observations of low energy nuclear reactions, a new type recoil mass-separator together with a new gas-jet target system is being developed at the tandem accelerator facility in Kyushu University. The expected mass-resolving power of the separator is 220 for a solid angle of 10 msr and the practical thickness of the gas-jet target will exceed 0.1 atm#centre dot#cm for the light elements of H and He. (author).

1994-06-01

214

A multi-megawatt X-band solid state microwave switch  

Energy Technology Data Exchange (ETDEWEB)

The authors present design methodology and initial experimental results for a high power microwave switch. The switch is designed for application to the pulse compression system associated with the Next Linear Collider Test Accelerator (NLCTA). The switch is based on the excitation of a plasma layer within a silicon wafer by either a laser or an electron beam. They investigate problems associated with high power operation of such a switch. They explore solutions to the problems of thermal runaway, avalanche breakdown, photo-emission, and secondary emission.

1995-12-31

215

The influence of target backing on ion-beam electron spectra  

International Nuclear Information System (INIS)

Several different aspects of the influence of the target backing on in-beam electron spectra following compound nuclear reactions induced by accelerated ions at tandem energies irradiating backed targets are discussed in detail. This discussion is illustrated by a few typical examples, such as "1"2C"5"+ and "3"1P"1"0"+ beams at 4 MeV/u bombarding Sn(+Be), Sn(+Au), Pb(+C) backed targets. Moreover, the relative influence of electron backscattering, electron Doppler shift and Doppler broadening as well as #delta#-electron emission on the low energy electron spectra (E_e#<=#100 keV) obtained under such conditions are investigated in the frame of the available experimental data. (orig.).

216

CLUSTER: a high frequency H-mode coupled cavity linac for low and medium energies  

CERN Document Server

We propose an innovative linear accelerating structure, particularly suited for hadrontherapy applications. Its two main features are compactness and good power efficiency at low beam velocities: the first is achieved through a high working frequency and a consequent high accelerating gradient, the second is obtained by coupling several H-mode cavities together. The structure is called CLUSTER, which stands for "Coupled-cavity Linac USing Transverse Electric Radial field". In order to compare the performance of this structure with other hadrontherapy linac designs involving high frequencies, a conceptual study has been performed for an operating frequency of 3 GHz. Moreover a proof of principle has been obtained through RF measurements on a prototype operating at 1 GHz. An accelerator complex using a CLUSTER linac is also considered for protontherapy purposes. The whole complex is called cyclinac and is ...

2006-01-01

217

REQUIREMENTS AND GUIDELINES FOR NSLS EXPERIMENTAL BEAM LINE VACUUM SYSTEMS-REVISION B.  

Energy Technology Data Exchange (ETDEWEB)

Typical beam lines are comprised of an assembly of vacuum valves and shutters referred to as a ''front end'', optical elements to monochromatize, focus and split the photon beam, and an experimental area where a target sample is placed into the photon beam and data from the interaction is detected and recorded. Windows are used to separate sections of beam lines that are not compatible with storage ring ultra high vacuum. Some experimental beam lines share a common vacuum with storage rings. Sections of beam lines are only allowed to vent up to atmospheric pressure using pure nitrogen gas after a vacuum barrier is established to protect ring vacuum. The front end may only be bled up when there is no current in the machine. This is especially true on the VUV storage ring where for most experiments, windows ...

1999-05-01

218

A high-power millimeter-wave sheet beam free-electron laser amplifier  

International Nuclear Information System (INIS)

The results of experiments with a short period (9.6 mm) wiggler sheet electron beam (1.0 mm x 2.0 cm) millimeter-wave free electron laser (FEL) amplifier are presented. This FEL amplifier utilized a strong wiggler field for sheet beam confinement in the narrow beam dimension and an offset-pole side-focusing technique for the wide dimension beam confinement. The beam analysis herein includes finite emittance and space-charge effects. High-current beam propagation was achieved as a result of extensive analytical studies and experimental optimization. A design optimization resulted in a low sensitivity to structure errors and beam velocity spread, as well as a low required beam energy. A maximum gain of 24 dB was achieved with a 1-kW injected signal power at 86 GHz, a 450-kV beam ...

219

Single-pass high-gain free electron laser electron beam diagnostics  

International Nuclear Information System (INIS)

Consensus reached in the last few years that fourth generation light source will most likely be a X-ray or a UV coherent source based on single-pass high-gain free electron laser (FEL), such as Self Amplified Spontaneous Emission (SASE), or seeded high-gain harmonic-generation (HGHG) free electron lasers. High-gain (>10"7) required for single-pass FEL puts great constrain on the quality of electron beam, and demands detailed distribution information of electron beam in six-dimension. The typical accelerator system for single-pass FEL consists of a photocathode RF gun injection system, a linac and magnetic bunch compressors, and a long undulator. The major challenges in beam diagnostics for single-pass FEL are to characterize the pico-seconds high-brightness electron beam in six-dimension produced by photocathode RF gun injector, and improve the stability and reliability of the ...

2000-11-27

220

Pulse power considerations for the generation of 45 #mu#s, 200 keV electron beams for CO_2 lasers  

International Nuclear Information System (INIS)

A two module electron beam source operating over a wide range of output parameters has been designed and fabricated to be used in conjunction with a pair of electron beam sustained CO_2 lasers. Each module comprised a grid-controlled thermionic electron beam gun including a compact grid pulser for control of the electron beam, a 250 kV thyratron switched modulator for acceleration of the electron beam, a 1 kHz filament heater and a complex computerized control system. The system was designed to reliably produce 45 #mu#s wide electron pulses of 150-200 keV energy, operate at repetition rates of 1-10 pps and current densities of 5-20 mA/cm"2. Additional parameters are listed. The high voltage cathode assembly employs 132 thoriated tungsten filaments distributed over the area of the 250 cm x 10 cm output window. The cathode assembly including the control grids is ...

1989-01-19

221

Optimal parameters for energy spectral calculations of mega voltage photon beam using Monte Carlo simulations  

International Nuclear Information System (INIS)

For the Convolution, Superposition and Monte Carlo methods, energy spectrum data is an essential parameter. Especially, by using Monte Carlo method, if the adequate properties of electrons are set, complex energy spectrum data can be calculated by simple input. However, adjustment of the property of electrons incident on the target of linear accelerator is time-consuming procedure. To cover the difference of many accelerators, it is important how we obtain accurate energy spectrum by simple methods. Especially, the total accuracy of dose calculation depends on the agreement of measured and calculated percentage depth dose (PDD) and off-axis ratio (OAR). Thus, a simple method for the determination of the simulation parameters was considered. To reduce the adjustment procedure, we selected values of important three parameters, which were the mean energy of the input electron beam, the energy distribution of the input electron ...

2005-06-01

222

Implementation of Accelerated Beam-Specific Matched-Filter-Based Optical Alignment  

Energy Technology Data Exchange (ETDEWEB)

Accurate automated alignment of laser beams in the National Ignition Facility (NIF) is essential for achieving extreme temperature and pressure required for inertial confinement fusion. The alignment achieved by the integrated control systems relies on algorithms processing video images to determine the position of the laser beam images in real-time. Alignment images that exhibit wide variations in beam quality require a matched-filter algorithm for position detection. One challenge in designing a matched-filter based algorithm is to construct a filter template that is resilient to variations in imaging conditions while guaranteeing accurate position determination. A second challenge is to process the image as fast as possible. This paper describes the development of a new analytical template that captures key recurring features present in the beam image to accurately estimate the ...

2009-01-29

223

Dynamics of a very intense pulsed electron beam  

Energy Technology Data Exchange (ETDEWEB)

A unique beam of pulsed electrons has been developed using the 19-MeV, 700-kA Hermes-III accelerator. The extended planar-anode diode is used to extract at large radius an annular electron beam from the accelerator and inject the resulting beam at small angle into a low-pressure gas cell, where the beam is rapidly charge neutralized and almost current neutralized. Under these conditions, the beam propagates nearly ballistically to a focus downstream of injection, where objects can be placed for irradiation and study. For a focal length of 78 cm, measurements with a segmented calorimeter show that this configuration can deliver an energy deposition of 200 J/g [20 Mrad] over a useful area of 70 cm{sup 2} and a 4-cm depth in graphite in 25 ns. Increasing the injection angle by reducing the AK gap permits higher doses over smaller areas to be ...

1994-12-31

224

The first insertion devices at SSRL - some personal recollections  

Energy Technology Data Exchange (ETDEWEB)

The author recounts his experiences with insertion devices at the Stanford Synchrotron Radiation Laboratory. His first experiences with wigglers occured at the Cambridge Electron Accelerator, and was carried over to SSRL with the proposal for a six pole electromagnetic wiggler. Most modern undulators, and many wigglers are now designed around permanent magnets, and the origin of this transition at SSRL was rather fortuitous and humorous. It reflects some of the personality characteristics of Klaus Halbach.

1995-02-01

225

Mercury flow experiments. 3. Simulation test plan under abnormal condition  

Energy Technology Data Exchange (ETDEWEB)

Japan Atomic Energy Research Institute (JAERI) and High Energy Accelerator Research Organization (KEK) are promoting construction plan of Material-Life Science Facility, which is consisted of Muon Science Facility and Neutron Scattering Facility, in order to open up the new science fields. The Neutron Scattering Facility will be utilized for advanced fields of Material and Life science using high intensity neutrons generated by the spallation reaction induced by injecting a 1 MW pulsed proton beam onto a mercury target. Design of the spallation mercury target system is in progress to obtain good neutron performance keeping high reliability and safety. The target material is mercury. As a result of the spallation reaction, large amount of radioactive spallation products are to be contained in the mercury. Therefore to establish the safety of the target system, transient behaviors of the system during anticipated events should be well understood. ...

2002-02-01

226

Heat transfer augmentation for high heat flux removal in rib-roughened narrow channels  

International Nuclear Information System (INIS)

Heat transfer augmentation in narrow rectangular channels in a target system is a very important method to remove high heat flux up to 12 MW/m"2 generated at target plates of a high-intensity proton accelerator of 1.5 GeV and 1 mA with a proton beam power of 1.5 MW. In this report, heat transfer coefficients and friction factors in narrow rectangular channels with one-sided rib-roughened surface were evaluated for fully developed flows in the range of the Reynolds number from 6,000 to 1,00,000; the rib pitch-to-height ratios (p/k) were 10,20 and 30; the rib height-to-equivalent diameter ratios (k/De) were 0.025, 0.03 and 0.1 by means of previous existing experimental correlations. The rib-roughened surface augmented heat transfer coefficients approximately 4 times higher than the smooth surface at Re=10,000, p/k=10 and k/De=0.1; friction factors increase around 22 times higher. In this case, higher heat flux up to 12 MW/m"2 could be removed ...

2001-04-08

227

Heat transfer augmentation for high heat flux removal in rib-roughened narrow channels  

Energy Technology Data Exchange (ETDEWEB)

Heat transfer augmentation in narrow rectangular channels in a target system is a very important method to remove high heat flux up to 12 MW/m{sup 2} generated at target plates of a high-intensity proton accelerator of 1.5 GeV and 1 mA with a proton beam power of 1.5 MW. In this report, heat transfer coefficients and friction factors in narrow rectangular channels with one-sided rib-roughened surface were evaluated for fully developed flows in the range of the Reynolds number from 6,000 to 1,00,000; the rib pitch-to-height ratios (p/k) were 10,20 and 30; the rib height-to-equivalent diameter ratios (k/De) were 0.025, 0.03 and 0.1 by means of previous existing experimental correlations. The rib-roughened surface augmented heat transfer coefficients approximately 4 times higher than the smooth surface at Re=10,000, p/k=10 and k/De=0.1; friction factors increase around 22 times higher. In this case, higher heat flux up to 12 MW/m{sup 2} could be ...

1997-03-01

228

Exotic nuclear spectroscopy: towards the doubly-magic Sn-100  

International Nuclear Information System (INIS)

Modern nuclear spectroscopy boosts the study of the nuclear matter towards extreme conditions: large excitation energies, high spins, and new nuclear species with unusual ratio between the numbers of neutrons and protons. One of the 'exotic' nuclear regions, practically not studied until now, is the upper part of the N=Z line, from about N#approx#Z#approx#36 to Sn-100, probably the heaviest bound nucleus with N=Z. These nuclei lie close to the proton-drip line. Due to their special composition, it is expected that their study will reveal some phenomena which are less encountered in the nuclei studied till now. In particular, of outstanding interest is the fact that these are the only nuclei which may provide information on the properties of the neutron-proton pairing forces. In spite of its large interest, this nuclear region is exceedingly difficult to reach with the present techniques. The lecture follows the latest results and efforts in the study of the heaviest nuclei with ...

2001-10-18

229

"Spin" and "Orbital" Flows in a Circularly Polarized Paraxial Beam: Orbital Rotation without Orbital Angular Momentum  

CERN Document Server

In light beams with circular or elliptic polarization, the transverse energy flow consists of the "spin" and "orbital" parts. Both of them can induce the orbital motion of microparticles suspended within the field of a light beam, and this should be taken into account in experiments on the spin-to-orbital angular momentum conversion. The character of the spin, orbital and total transverse energy flows in circular Laguerre-Gaussian beams is studied analytically; graphical representations of the flows in the beam cross section (flow maps) are calculated and analyzed. The spin circulatory flow can be directed oppositely to the orbital one and/or to the polarization handedness. As a result, the total transverse energy circulation of a beam with homogeneous circular polarization can be of different handedness in different regions of the beam ...

2009-01-01

230

Using of beam spoilers in linear accelerators with photons of 10 MV  

International Nuclear Information System (INIS)

This work come along of the necessity to utilize an unique High-Energy Electron Linear Accelerator (10 MV) for radiant treatments which require higher doses in the surface levels of tissue. It is analyzed the interposition of acrylic degraders (spoilers) in the beam, especially for opposed and parallel fields in the cases of head and neck. It was analyzed the possible combinations of the following parameters: 1) Field sizes defined at isocenter (100 cm) 6 x 6 cm"2, 8 x 8 cm"2 and 10 x 10 cm"2 ; 2) Surface-spoiler distance (DSS) of 4, 7 and 10 cm; 3) Spoilers with different thickness 1.1 and 1.5 cm. It was observed a displacement of the maximum dose toward the surface, and an increase in the percentile doses in the build-up zone when the spoiler is nearing and/or increasing its thickness. It is verified that the use of spoilers, support the symmetry and plane of the beam inside of the clinically acceptable margins. When the ...

1998-11-22

231

Study of the Smith-Purcell effect in the relativistic regime  

International Nuclear Information System (INIS)

We propose to investigate the spontaneous emission of radiation arising out of the interaction of a relativistic electron beam with a metallic grating (the Smith-Purcell effect). The work will concentrate, primarily, in the 50-120 #mu#m part of the infrared spectrum and will be an extension of the work begun by the Oxford-Dartmouth-Essex collaboration; one of the early objectives of the project will be to develop a quantitative understanding of the power spectrum of the emitted radiation over a wide range of emission angles. In particular, the limits of relativistic peaking of forward directed emission will be investigated. The electron beam will be produced by laser irradiation of a metallic cathode in the terminal of a small Van de Graff accelerator located in the Technische Universitaet, Muenchen. Beam energies will be in the range of 2 - 4 MeV. Initial tests on photoproduction of electrons have ...

1995-08-21

232

An identification method of positron production in laser beam interaction with targets  

Energy Technology Data Exchange (ETDEWEB)

A simple electromagnetic transport system was constructed to identify very rare positrons produced in a powerful laser beam interaction with a target. Testing experiments were carried out with CO[sub 2]-laser (10[sup 12] W/cm[sup 2]) beam pulses ([tau] = 50 ns, f = 0.01 Hz) focused on the copper target, as well as with a 96 MeV alpha-particle beam irradiated carbon target. The results showed that the developed system could be effectively used for positron identification and evaluation of their energy by means of a time-of-flight method. The computerized system to deal with this problem, together with others related to the power laser beam interaction with targets, has been constructed. (orig.).

1992-10-01

233

Versatile high intensity plasma sputter heavy negative ion source  

Energy Technology Data Exchange (ETDEWEB)

A multicusp magnetic field plasma surface ion source, normally used for H/sup -/ ion beam formation, has been utilized for the generation of high intensity, pulsed, heavy negative ion beams suitable for a variety of uses including tandem electrostatic accelerator/synchrotron injection applications. Sputter probe voltage limited total ion currents of 5.5, 8.2, 5.1 and 4.5 mA (peak intensity) have been produced from Au, Cu, Ni and CuO sputter probes, respectively. The mass distributions of these ion beams are found to be dominated by Au/sup -/, Cu/sup -/, Ni/sup -/ and O/sup -/ atomic species, respectively. The source offers the interesting prospect of providing cw negative ion beams at mA intensity levels of the commonly used semiconducting material dopants (e.g. B/sup -/, P/sup -/, As/sup -/ and Sb/sup -/) as well as O/sup -/ for isolation barrier formation. Illustrative examples of ...

1988-07-01

234

Parametric Resonance Ionization Cooling and Reverse Emittance Exchange for Muon Collider  

Energy Technology Data Exchange (ETDEWEB)

Two methods to cool muon beams deeply below the limit conventionally established for the ionization cooling are proposed. In Phase Ionization Cooling (PIC), the beam is focused at wedge absorber plates each half of particle oscillation period by imposing a weak parametric resonance along the beam path. The resonance growth of particle amplitude is surmounted by the ionization cooling. At optimum, such arrangement results in reduction of each of two transverse emittances by an order of value in addition to the preceding 6D ionization cooling. Next, resonance focusing and transverse cooling can be continued in the regime of a fast Reverse Emittance Exchange (REMEX). Here, the sign of the absorber wedge is opposite to PIC while the dispersion increased. REMEX to be accompanied by the bunch lengthening and acceleration in order to maintain the relative energy spread at an appropriate level. The limitations ...

2005-09-18

235

Electron diodes and cavity design for the new 4-MeV injector of the recirculating linear accelerator (RLA)  

International Nuclear Information System (INIS)

The authors have designed and constructed four types of electron-beam diodes for the new 4-MV RLA injector: a non-immersed foilless diode, a magnetically immersed foilless diode, a foil diode and an ion-focused foilless diode, They are tailored to fit the new injector cavity. The design goals were to produce high quality 10-kA to 20-kA electron beams with a #beta# perpendicular smaller than 0.2 and a beam radius of the order of 2 cm. These beams will be matched to the RLA IFR channel so #beta# perpendicular must be equal to or smaller than the square root of the ratio of the beam current versus Alfven current for f_e = 1. A reentrant anode geometry was selected for the injector cavity design, because it offers substantial savings on the required amount of feromagnetic cores. The inner radius of the outside shell, now only 30 cm, would have been twice as large (60 cm) if a coaxial ...

1991-03-01

236

Complex radiation degradation behaviour of PVC materials under accelerated aging conditions  

International Nuclear Information System (INIS)

The radiation degradation behavior of three commercial polyvinyl chloride (PVC) materials has been investigated. All three exhibit an interesting reversal in the trend of the tensile strength part way through the aging experiment: the tensile strength first drops, then rises. The early drop is associated with oxidative scission; the rise is associated with crosslinking and is preceded by the material reaching the gel point. It was also found that the tensile elongation tended to level out in advanced stages of aging with the levelling-out values dependent on the dose rate. These phenomena pose complications for the design of accelerated aging tests. (author).

1982-10-01

237

Complex radiation degradation behavior of PVC materials under accelerated aging conditions  

Energy Technology Data Exchange (ETDEWEB)

The radiation degradation behavior of three commercial polyvinyl chloride (PVC) materials has been investigated. All three exhibit an interesting reversal in the trend of the tensile strength part way through the aging experiment: the tensile strength first drops, then rises. The early drop is associated with oxidative scission; the rise is associated with crosslinking and is preceded by the material reaching the gel point. It was also found that the tensile elongation tended to level out in advanced stages of aging with the leveling-out values dependent on the dose rate. These phenomena pose complications for the design of accelerated aging tests.

1983-07-01

238

rf-driven ion sources for industrial applications (invited) (abstract)  

Science.gov (United States)

The Plasma and Ion Source Technology Group at the Lawrence Berkeley National Laboratory have been developing rf-driven ion sources for the last two decades. These sources are being used to generate both positive and negative ion beams. Some of these sources are operating in particle accelerators such as the Spallation Neutron Source (SNS) at Oak Ridge, while others are being employed in various industrial ion beam systems. There are four areas where the rf-driven ion sources are commonly used in industry. (1) In semiconductor manufacturing, rf-driven sources have found important applications in plasma etching, ion beam implantation, and ion beam lithography. (2) In material analysis and surface modification, miniature rf-ion sources can be found in focused ion beam systems. They can provide ion beams of essentially any element in the ...

2008-02-15

239

The ANL X6B beamline at NSLS: A versatile facility  

Energy Technology Data Exchange (ETDEWEB)

We have described the x-ray optics and beamline performance of the ANL X6B beam line at the NSLS. Considerable flexibility has been built into the beam line to accommodate a wide range of x-ray diffraction, scattering, and spectroscopy experiments with various requirements. We presented selected examples of experimental results and showed that with the high intensity, high energy resolution, high-q resolution, and energy tunability, the X6B beam line has become a versatile facility.

1994-07-01

240

Operational Experience with LHC Collimation  

CERN Document Server

A first sub-set of the collimation system has been installed for the 2008 first beam commissioning of the LHC. It included 88 collimators around the ring and the two injection lines. Each collimator has two jaws for which must be controlled and monitored with high precision. The LHC collimation system was put into operation from July to October 2008. The installed system is described and first results from system operation without and with beam are presented. It is shown that the LHC collimation system achieved the specified accuracy and reproducibility of jaw positioning. Next steps in collimation commissioning are described and planned system upgrades for high beam intensities are outlined.

2009-01-01

241

Automatic beam position control at Los Alamos Spallation Radiation Effects Facility (LASREF)  

Energy Technology Data Exchange (ETDEWEB)

Historically the Los Alamos Spallation Radiation Effects Facility (LASREF) has used manual methods to control the position of the 800 kW, 800 MeV proton beam on targets. New experiments, however, require more stringent position control more frequently than can be done manually for long periods of time. Data from an existing harp is used to automatically adjust steering magnets to maintain beam position to required tolerances.

1997-08-01

242

Application of a 3-beam #gamma# densitometer to two-phase flow regime and density measurements  

International Nuclear Information System (INIS)

A method of using gamma radiation to determine the density and phase distribution in two-phase flows in pipes is described. Three collimated beams of radiation that pass through a pipe cross-section at different radial positions are used. A theory and computer program used to relate the measured attenuation of these beams to a three-parameter model of the phase distribution and to the average density and void fraction are discussed. Data obtained during both static and dynamic verification experiments using Lucite inserts are presented, as well as the results of several tests done in high pressure, steam-water flows.

1976-08-11

243

Microwave axial free-electron laser with enhanced phase stability  

International Nuclear Information System (INIS)

Free-electron laser (FEL) amplifiers have demonstrated high efficiencies and high output power at microwave wavelengths. However, measurements and simulations have indicated that the present level of phase stability for these devices is not sufficient for driving linear accelerators. Fluctuations in the diode voltage, which is needed to accelerate the electron beam, are the largest cause of the shifts in the phase of the output power. Pulse-power technology cannot keep the voltage fluctuations less than 1/4%. However, we have found a scheme that will make the output phase much less sensitive to these fluctuations by exploiting the traveling wave nature of the FEL interaction. In this paper we study the phase stability issue by analyzing the dispersion relation for an axial FEL, in which the rf field is transversely wiggled and the electron trajectories are purely longitudinal. The advantage of using the axial FEL ...

1995-08-21

244

Wire chamber degradation at the Argonne ZGS  

International Nuclear Information System (INIS)

Experience with multiwire proportional chambers at high rates at the Argonne Zero Gradient Synchrotron is described. A buildup of silicon on the sense wires was observed where the beam passed through the chamber. Analysis of the chamber gas indicated that the density of silicon was probably less than 10 ppM.

1986-01-16

245

Wire chamber degradation at the Argonne ZGS  

Energy Technology Data Exchange (ETDEWEB)

Experience with multiwire proportional chambers at high rates at the Argonne Zero Gradient Synchrotron is described. A buildup of silicon on the sense wires was observed where the beam passed through the chamber. Analysis of the chamber gas indicated that the density of silicon was probably less than 10 ppM.

1986-01-01

246

Weekly total skin electron beam therapy for mycosis fungoides and other cutaneous lymphomata: further experience.  

UK PubMed Central (United Kingdom)

Lymphomatous processes involving the skin can be managed effectively by total skin electron beam irradiation. A technique using weekly doses (400 rad for each of 6 successive weeks) has been employed...Full Text Available

1975-03-01

247

e#gamma# and #gamma##gamma# colliders  

International Nuclear Information System (INIS)

The results that can be expected by e#gamma# and #gamma##gamma# colliders in future are summarized. e#gamma# and #gamma##gamma# colliders have many fine possibilities, and are the economical selection for utilizing future e"+e"- colliders more effectively. e#gamma# and #gamma##gamma# colliders were proposed by former USSR researchers at the beginning of 1980s, but recently, the prospect of realizing future e"+e"- collision type linear accelerator projects has become high, they have become to be considered seriously as the option of remodeling them. The high energy photon beam of e#gamma# and #gamma##gamma# colliders is obtained by causing Compton reverse scattering, irradiating laser beam to the electron beam of e"+e"- accelerators. The production of #gamma#-beam is explained. As for the physics noteworthy in e#gamma# colliders, abnormal gauge coupling, the ...

1994-02-01

248

Recent progress of the JAERI free electron laser driven by a compact superconducting RF linac  

International Nuclear Information System (INIS)

A prototype for a quasi-cw, and high-average power free electron laser (FEL) driven by a 15 MeV superconducting rf linac has been developed, and constructed at Tokai, JAERI since 1989. Cryogenic and accelerating fields' performances of four JAERI superconducting accelerator modules have been realized without any serious problem in the FEL accelerator vault and experimental hall. Since modification and related maintenance of the cryogenic refrigerator system for the driver were completed in the middle of October 1995, the system has run with no trouble, and the driver has been continuously run very successfully up to now. The optical resonator system and related electron beam transport system have been modified to realize larger acceptance than the old for both of the undulator radiation and energetic electron beam in 1995 Japanese fiscal year. In the modification, an alignment and ...

1997-02-28

249

E{gamma} and {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

The results that can be expected by e{gamma} and {gamma}{gamma} colliders in future are summarized. e{gamma} and {gamma}{gamma} colliders have many fine possibilities, and are the economical selection for utilizing future e{sup +}e{sup -} colliders more effectively. e{gamma} and {gamma}{gamma} colliders were proposed by former USSR researchers at the beginning of 1980s, but recently, the prospect of realizing future e{sup +}e{sup -} collision type linear accelerator projects has become high, they have become to be considered seriously as the option of remodeling them. The high energy photon beam of e{gamma} and {gamma}{gamma} colliders is obtained by causing Compton reverse scattering, irradiating laser beam to the electron beam of e{sup +}e{sup -} accelerators. The production of {gamma}-beam is explained. As for the physics noteworthy in e{gamma} colliders, ...

1994-02-01

250

Comparisons of Monte Carlo calculations with absorbed dose determinations in flat materials using high-current, energetic electron beams  

International Nuclear Information System (INIS)

International standards and guidelines for calibrating high-dose dosimetry systems to be used in industrial radiation processing recommend that dose-rate effects on dosimeters be evaluated under conditions of use. This is important when the irradiation relies on high-current electron accelerators, which usually provide very high dose-rates. However, most dosimeter calibration facilities use low-intensity gamma radiation or low-current electron accelerators, which deliver comparatively low dose-rates. Because of issues of thermal conductivity and response, portable calorimeters cannot be practically used with high-current accelerators, where product conveyor speeds under an electron beam can exceed several meters per second and the calorimeter is not suitable for use with product handling systems. As an alternative, Monte Carlo calculations can give theoretical estimates of the absorbed dose in materials ...

2007-08-01

251

The HARP experiment first physics results  

CERN Document Server

The HARP experiment at CERN is performing extensive measurements of hadron production cross sections and secondary particle yields, in the momentum range 1.5-15 GeV/c, over the full solid angle and using a large set of cryogenic and solid targets. First measurements of hadron production cross-sections in the forward region are reported using an aluminium target 5% of an interaction length thick and a proton beam of 12.9 GeV/c. A preliminary analysis in the large angle region of elastic scattering events produced with the cryogenic hydrogen target at 3 GeV/c beam momentum is also presented.

2005-01-01

252

High power testing of a 17 GHz photocathode RF gun  

Energy Technology Data Exchange (ETDEWEB)

The authors report experimental results on a high gradient 17 GHz RF photocathode gun. The photocathode RF gun is a novel electron beam source intended to meet the requirements set by future high-energy linear colliders and next generation free electron lasers. A coupled pair of pillbox TM{sub 010}-like resonators is excited by sidewall coupled microwaves at 17 GHz. A picosecond ultraviolet laser pulse illuminates one wall of the structure at the axis of symmetry. Electrons are released by the photoelectric effect and are accelerated by the electric field of the microwaves in the cavity. The high frequency of operation raises the RF breakdown limit allowing strong electric fields to be used. In turn, the intense fields result in rapid acceleration of the electrons to relativistic speeds and reduced space charge induced emittance growth.

1996-12-31

253

Energy saver A-sector power test results  

Energy Technology Data Exchange (ETDEWEB)

The superconducting magnets and associated cryogenic components in A-sector represent the initial phase of installation of the Fermilab superconducting accelerator, designed to accelerate proton beams to energies of 1 TeV. Installation of the magnets, comprising one-eighth of the ring, was completed in December, 1981. Cooldown and power tests took place in the first half of 1982, concurrent with main ring use for 400 GeV high energy physics. The tests described in this paper involved 151 cryogenic components in the tunnel: 94 dipoles, 24 quadrupoles, 25 spool pieces, 3 feed cans, 4 turn-around boxes and 1 bypass. Refrigeration was supplied by three satellite refrigerators, the Central Helium Liquefier, and two compressor buildings. The magnets were powered by a single power supply.

1982-09-15

254

Construction and development of a UV free electron laser under the cooperation of Nihon U, KEK, PNC, ETL and Tohoku U  

Energy Technology Data Exchange (ETDEWEB)

The construction and the development of a UV free electron laser have been started under the cooperation of Nihon U, KEK, PNC, ETL and Tohaku U. The project requires a 100MeV S-band electron linear accelerator to expand the oscillation of FEL using fundamental mode to the UV region. The injection system consists of a thermionic RF-gun with a LaB cathode and an {alpha} magnet for magnetic bunching. We are studying to reduce the back-bombardment electrons to realize the macropulse length of 20{mu}sec. Electron beams, up to the energy of 100MeV, are injected into the optical oscillators. Changing the accelerating energy and/or undulator parameters, this system will cover the range from infrared to ultraviolet for the applications in various fields.

1995-12-31

255

Calorimetric sensors for energy deposition measurements  

Energy Technology Data Exchange (ETDEWEB)

A calorimetric sensor with several novel design features has been developed. These sensors will provide an accurate sampling of thermal power density and energy deposition from proton beams incident on target components of accelerator-based systems, such as the Accelerator Production of Tritium Project (APT) and the Spallation Neutron Source (SNS). A small, solid slug (volume = 0.347 cc) of target material is suspended by kevlar fibers and surrounded by an adiabatic enclosure in an insulating vacuum canister of stainless steel construction. The slug is in thermal contact with a low-mass, calibrated, 100-k{Omega} thermistor. Power deposition caused by the passage of radiation through the slug is calculated from the rate of temperature rise of the slug. The authors have chosen slugs composed of Pb, Al, and LiAl.

1998-12-31

256

Integrated Numerical Experiments (INEX) and the Free-Electron Laser Physical Process Code (FELPPC)  

International Nuclear Information System (INIS)

The strong coupling of subsystem elements, such as the accelerator, wiggler, and optics, greatly complicates the understanding and design of a free electron laser (FEL), even at the conceptual level. To address the strong coupling character of the FEL the concept of an Integrated Numerical Experiment (INEX) was proposed. Unique features of the INEX approach are consistency and numerical equivalence of experimental diagnostics. The equivalent numerical diagnostics mitigates the major problem of misinterpretation that often occurs when theoretical and experimental data are compared. The INEX approach has been applied to a large number of accelerator and FEL experiments. Overall, the agreement between INEX and the experiments is very good. Despite the success of INEX, the approach is difficult to apply to trade-off and initial design studies because of the significant manpower and ...

1990-07-01

257

Vibration experiment for a three-loop PWR reactor building  

Energy Technology Data Exchange (ETDEWEB)

Forced vibration experiment has been conducted for the reactor building of Sendai Unit 1 nuclear power plant. The beam vibrational behaviors of the outer shielding building and the internal concrete structure have been observed by using a 50 tf vibration for low frequency region, and a 10 tf vibration for high frequency region, respectively. The outline of the experimental methods, the data handling system and the major results of experiment are described. The experimental results were simulated by an analytical model. The proper vibrational frequency and the vibration modes obtained by the analysis were compared with those obtained by the experiment. By these comparisons, the adequacy of the analytical method employed for the design was confirmed.

1983-12-01

258

Population doses from beam-therapy in Japan, 1978, 3  

International Nuclear Information System (INIS)

As a series of estimations of population doses and of risk estimates from medical exposures in Japan, the malignancy significant dose (MSD) and the fatal malignant risk from beam therapy were estimated based on a nationwide survey of radiotherapeutic treatments, using a malignancy significant factor and a weighting factor determined from the data on the cancer mortality among the atomic bomb survivors in Nagasaki. The effective dose was defined as a sum of the product of the weighting factor and the organ or tissue doses with respect to the malignant diseases. The organ or tissue doses were determined with ionization chambers placed at the positions of their center in a MixDp-phantom simulated lung tissues by a block of cork, using a telecobalt unit, a conventional X-ray unit and a medical linear accelerator. The organ or tissue doses were categorized into three dose components; namely 1) dose from useful beams; 2) ...

1981-01-01

259

Ultra high-speed (508 MHz) beam position digital feedback system  

Energy Technology Data Exchange (ETDEWEB)

The B-Factory which is constructed by National Laboratory for High Energy Physics is the device for elucidating the breakdown of symmetry of matter and antimatter by studying the behavior of B mesons which are generated in large quantity when the electrons and the positrons which are accelerated to light velocity level are collided. In order to maintain electron beam-positron beam bunch circling the ring at light velocity stably, the instability of the coupled bunch must be overcome. For this purpose, the ultrahigh speed beam position digital feedback control system was developed. This system is composed of the high speed input-output substrate using GaAs LSI, the feedback computation substrate using complementary metal oxide semiconductor and the memory mounted on it, and the real time operation device. The development of both substrates and their functions are explained. The real time data collection ...

1997-02-01

260

Radioisotope production in the I.Ph.P.E. cyclotron for medical application  

International Nuclear Information System (INIS)

The production methods for seven radioisotopes, Ga-67, Sr-85, Pd-103, In-111, Tu-167, Hg-197 and Pb-203, by using a classical 1.5m cyclotron in the Institute of Physics and Power Engineering, Obninsk, USSR, are described. At present, more than 50 cyclotrons in different countries are used for the production of radioisotopes applied to medicine. Radioisotopes are produced with the cyclotron in the I.Ph.P.E. in the form of irradiated targets, which are delivered to Moscow radiopharmaceutical factory, where radiopharmaceuticals are produced on the base of these targets. The cyclotron is operated in two regimes providing the acceleration of protons, deuterons and alpha -particles. Two types of target assemblies are used for irradiation, the one is intended for the internal beam, and the other is for the external beam. The reactions used for the production of seven radioisotopes described above, the types of targets, particle ...

261

Radioisotope production in the I. Ph. P. E. cyclotron for medical application  

Energy Technology Data Exchange (ETDEWEB)

The production methods for seven radioisotopes, Ga-67, Sr-85, Pd-103, In-111, Tm-167, Hg-197 and Pb-203, by using a classical 1.5m cyclotron in the Institute of Physics and Power Engineering, Obninsk, USSR, are described. At present, more than 50 cyclotrons in different countries are used for the production of radioisotopes applied to medicine. Radioisotopes are produced with the cyclotron in the I.Ph.P.E. in the form of irradiated targets, which are delivered to Moscow radiopharmaceutical factory, where radiopharmaceuticals are produced on the base of these targets. The cyclotron is operated in two regimes providing the acceleration of protons, deuterons and alpha -particles. Two types of target assemblies are used for irradiation, the one is intended for the internal beam, and the other is for the external beam. The reactions used for the production of seven radioisotopes described above, the types of targets, particle ...

1982-01-01

262

Accelerator technology program. Progress report, April-December 1978  

Science.gov (United States)

This report presents highlights of activities in the Acceleartor Technology (AT) Division from April through December 1978. The report is divided into 10 sections to cover work done by the four groups that make up AT Division (AT-1, AT-2, AT-3, and AT-4). Section I is a brief summary of the whole report. Sections II through VI describe work done by At-1, the Linac Technology Group. Subjects covered are the Pion Generation for Medical Irradiation Program, the Electronuclear Fuel-Producing Accelerator Program, the Gyrocon rf Amplifier Program, the Electron Linear Accelerator Program, and the Free Electron Laser Program. Section VII covers the Linear Accelerator Beam Dynamics development, and Sec. VIII deals with work with the H/sup -/ Ion Source. Most of the work in Secs. VII and VIII was done by AT-2, the Special Projects Group, although work on factors influencing emittance growth was done by MP-9, and ...

1980-05-01

263

Study on the characterization of the neutron radiography facility in HANARO for two-phase flow research  

Energy Technology Data Exchange (ETDEWEB)

For the application of dynamic neutron radiography to the two-phase flow research using HANARO, several experimental items to which the radiography technique is beneficial were identified through the review of the outputs from the related researches and the discussions with experts. Also, the investigation of the equipments including the beam port, camera and converter was made and a hardware and a software for image processing were equipped. It was confirmed that the calibration curve for the attenuation of neutron beam in fluid which is required for the two-phase flow experiment could be obtained by the computer code calculation. Based on the investigation results on the equipment and the results from the measurement of BNCT beam characteristics, a high speed camera and an image intensifier will be purchased. Then, the high speed dynamic neutron radiography facility for two-phase flow ...

2001-01-01

264

Smoothing of laser energy deposition by gas jets  

International Nuclear Information System (INIS)

Smoothing of laser beam non-uniformities using gas jets has been studied. The experiment has been performed with the PALS (Prague Asterix Laser System) laser working at 0.44 ?m with an intensity of about 1015 W/cm2. The laser beam has been split in two by a prism thus creating an artificial large-scale non-uniformity (? 90 ?m). We recorded time resolved and static images of laser-gas jet interaction with and without an Al target. Multi 1-dimensional and 2-dimensional simulations show that such interaction acts redistributing the over-intensities over larger surface. This effect has to be attributed to ionization processes with consequent laser beam refraction. Results show that Argon gas jet produces a strong refraction of the laser beam thus strongly reducing the initial two spots separation. (authors)

2009-08-01

265

Results from a Prototype Chicane-Based Energy Spectrometer for a Linear Collider  

Energy Technology Data Exchange (ETDEWEB)

The International Linear Collider (ILC) and other proposed high energy e{sup +}e{sup -} machines aim to measure with unprecedented precision Standard Model quantities and new, not yet discovered phenomena. One of the main requirements for achieving this goal is a measurement of the incident beam energy with an uncertainty close to 10{sup -4}. This article presents the analysis of data from a prototype energy spectrometer commissioned in 2006-2007 in SLAC's End Station A beamline. The prototype was a 4-magnet chicane equipped with beam position monitors measuring small changes of the beam orbit through the chicane at different beam energies. A single bunch energy resolution close to 5 {center_dot} 10{sup -4} was measured, which is satisfactory for most scenarios. We also report on the operational experience with the chicane-based spectrometer and suggest ways of improving ...

2011-02-28

266

Precise measurement of a focused ion beam profile  

Energy Technology Data Exchange (ETDEWEB)

The profile of focused boron ion beam (FIB) from a liquid metal ion source was determined by MOS device characteristics and resist exposure experiments. A focused boron ion beam was line-scanned into the middle of the channel region along the source to drain direction of a MOSFET, and the effective channel width is determined from electrical measurements. PMMA resist was also exposed by a line-scanned boron FIB and the developed contour was observed by a SEM. The profile of the focused boron ion beam with a diameter of around 0.2 ..mu..m was determined by these two methods and it was found to have about a 1 ..mu..m wide tail at around three orders of magnitude below the peak current density region. The profile difference between the two measurements are attributed to the boron diffusion in silicon by subsequent heat-treatments during device fabrication.

1987-06-01

267

Beam Motes  

ScienceCinema

...english the ...

268

Study of the reaction {sup 22}Ne(131 MeV) + {sup 208}Pb with a PIAVE-ALPI test beam and the PRISMA-CLARA set-up  

Energy Technology Data Exchange (ETDEWEB)

An opportunity to study the system {sup 22}Ne+{sup 208}Pb in the proximity of the Coulomb barrier with the PRISMACLARA apparatus was given by a test of the PIAVE-ALPI accelerator in mid-December 2005. The {sup 22}Ne projectiles, having the kinetic energy of 131 MeV, collided with a {sup 208}Pb target 300 {mu}g/cm{sup 2} thick. (The beam was run for {approx}20 hours with a current of {approx}6 particle-nA). The reaction products, mainly originated by scattering or transfer processes, were detected by the PRISMA spectrometer (positioned in the proximity of the grazing angle, {approx}70 degrees), coupled to the CLARA array of germanium detectors.

2005-07-01

269

Production of radioisotopes in the ORNL 86-inch cyclotron  

Energy Technology Data Exchange (ETDEWEB)

The radioisotope production facilities and programs of the 86-Inch Cyclotron are reviewed in this presentation. The 86-Inch Cyclotron is designed to accelerate protons to a maximum energy of 22 MeV for internal targets. These protons are used to bombard metals that are electroplated, potted or soldered to water-cooled plates. Additionally, metals and inorganic compounds are bombarded in water-cooled tube targets. High radioisotope production rates are obtained by beam currents as large as 3 mA. Production rates for /sup 11/C, /sup 57/Co, /sup 67/Ga, /sup 68/Ge, /sup 109/Cd, and other isotopes are presented. The production of /sup 11/C for the carboxyl labeling of amino acids in cooperation with Oak Ridge Associated Universities is discussed. The 86-Inch Cyclotron is used for those programs requiring a larger beam current than is available from commercial cyclotrons.

1981-04-01

270

Physical properties of wood-polymer composites prepared by an electron beam accelerator  

Energy Technology Data Exchange (ETDEWEB)

The dual characteristics in the performance of polymers in wood-polymer composites systems have been pursued with regard to the resolution of mechanical anisotropy of wood and the improvement in dimensional stability. The objective of the present study is to pursue the polymerization mechanism in wood under electron beam irradiation and the temperature dependence of polymer-wood interactions induced at various levels of higher order structure of wood in order to understand the polymer performance. Veneers used in the study were of rotary-cut beech (Fagus crenata Blume) 0.65 mm thick. All samples were oven-dried in vacuo at 80/sup 0/C for 30 hr. The monomers used in the study were methyl methacrylate, styrene, acrylic acid, acrylonitrile, and unsaturated polyester. Experimental details are given. Results are given and discussed.

1981-01-01

271

Nuclear astrophysics with radioactive ion beams  

International Nuclear Information System (INIS)

Nuclear astrophysics seeks for a possible explanation of the observed abundance distribution of various elements and their isotopes in the universe. Most of the relevant nuclear reactions take place in thermally equilibrium environments with bare nuclei, rather than accelerated and head-on colliding situations with low ionisation states of reactant atoms and molecules that are emulated in the laboratories. Moreover, the temperature of the astrophysical environments is quite often low compared to the centre-of-mass energy of the projectile nuclides, that is required for the reaction to be meaningfully investigated in the laboratory. Therefore, an extrapolation of the data on the reaction cross sections to very low energies and to extremely high density situations is generally called for, which are substantially altered every now and then for a number of astrophysically important reactions. The radioactive ion beams will provide us important data ...

272

2007 2008 ACADEMIC TRAINING PROGRAMME  

CERN Multimedia

LECTURE SERIES 14, 15, 17 January 2008 11:00 to 12:00 - Council Chamber, bldg. 503-1-001 Applications of accelerators to tumour therapy U. AMALDI, TERA Foundation & University of Milano Bicocca The first lecture is devoted to an historical review of the developments of the teletherapy techniques which make use of hadron beams and are collectively called "hadrontherapy". The main emphasis is on the use of protons and light ions, but also neutrons, pions and antiprotons are considered. The second lecture reviews the rationale behind the use of carbon ions in the treatment of radioresistant tumours and the results obtained both with proton and carbon ion beams on the 60 000 patients treated worldwide. The numbers of patients who would profit from hadrontherapy are presented together with the current landscape of running and planned hospital based centres. The main technical challenges set by this therapeutic modality are ...

2007-01-01

273

1. 55 [mu]m buried ridge stripe laser diodes grown by gas source molecular beam epitaxy  

Energy Technology Data Exchange (ETDEWEB)

Buried ridge stripe lasers have been grown on InP in two steps by gas source molecular beam epitaxy. The active structure consists of a compressively strained layer multi quantum well with an equivalent wavelength emission at 1.5 [mu]m. The stripe was defined by reactive ion etching. A threshold current of 22 mA was reproducibly obtained on a laser length of 500 [mu]m. A CW output power of 48 mW per facet was achieved. In addition, preliminary accelerated aging tests have shown the high reliability the structure. (orig.)

1993-02-01

274

Activation of Polymethyl-Methacrylate by Proton Beam  

International Nuclear Information System (INIS)

Activation has been used for many kinds of useful applications, such as use of the radioisotopes for diagnosis and treatment of cancer, and wear (or corrosion) investigation for using thin layer activation (TLA) technique, etc. But activation also has severe problems for the post-processing of the samples; such as time-loss, inconvenience of sample handling, personal radiation safety, etc. For in-vitro experiments, we observed death of tumor cells by proton irradiation. The use of large activated container material can cause erroneous results in this case. To solve these problems, we studied why the samples were activated and how the level of the activation could be reduced. In proton beam irradiation experiments, the target materials could be defined as the container and sample itself. We could easily reduce activation of container material comparing to activation of sample itself. Therefore, we tried to find less ...

2010-10-01

275

The effect of the primary collimator and flattening filter on asymmetric fields for a Siemens PRIMUS linear accelerator  

CERN Document Server

Homogeneity for highly asymmetric fields has been studied for a Siemens PRIMUS linear accelerator. The flattening filter has a radius smaller than the primary collimator one, creating inhomogeneities that affect large fields in areas far from the collimator axis, and asymmetric fields with large offset. Profiles and absolute dose have been measured in fields with two jaws at maximal position (20 cm) and the other two at maximal overtravel (10 cm.), corresponding to 10 x 10 fields with extreme offset. Profiles have a remarkable gradient decreasing towards the beam edge, making these fields unsuitable for treatments. Results show that the design of the primary collimator and flattening filter assembly has direct consequences in homogeneity. This can have clinical consequences for treatments involving fields that include these inhomogeneous areas. Comparisons with the treatment planning system (Philips Pinnacle) calculations, that computes under ...

2005-01-01

276

CARM-klystron amplifier for accelerator applications  

International Nuclear Information System (INIS)

We consider the possibility of a cyclotron-autoresonance-maser (CARM) klystron configuration for accelerator applications as an alternative to the gyroklystron amplifier. The potential advantages, compared to gyroklystrons, include: 1) comparable efficiencies at lower values of the electron beam pitch ratio #alpha#, which should improve the beam quality and make the device substantially more stable against the excitation of parasitic mode, 2) operation far from cutoff, which should reduce the fields at cavity walls, allowing higher power operation, and 3) operation at lower magnetic fields for the same cyclotron harmonic number. However, there are two significant issues associated with the design of efficient, high-power CARMs. First, because of the higher value of k_Z, compared to gyroklystrons, CARMs are substantially more sensitive to parallel velocity spread (pitch-angle spread). Second, conventional cavities support a ...

2001-05-31

277

Proceedings of the 2. international conference on accelerator-driven transmutation technologies and applications  

International Nuclear Information System (INIS)

Technical developments in the construction of high power accelerators have created new research activities on accelerator-driven transmutation technologies (ADTT) with main applications for energy production and nuclear waste transmutation. The on-going research was reported and discussed at the conference. The studies of energy production based on ADTT indicate possible important advantages compared to the present nuclear power reactors. Natural Uranium or Thorium is burned in a subcritical reactor with or without simultaneous incineration and transmutation of nuclear waste. High level radioactive wastes and weapons Plutonium constitute an environmental and proliferation problem. Studies were reported on the possibilities to use ADTT to considerably shorten the life-time and reduce the amount of long-lived radioactive waste in order to decrease the volumes needed for long-term geologic deposition. A panel discussed the ADTT impact on nuclear ...

1996-06-03

278

High-efficiency Resonant rf Spin Rotator with Broad Phase Space Acceptance for Pulsed Polarized Cold Neutron Beams  

Energy Technology Data Exchange (ETDEWEB)

High precision fundamental neutron physics experiments have been proposed for the intense pulsed spallation neutron beams at JSNS, LANSCE, and SNS to test the standard model and search for new physics. Certain systematic effects in some of these experiments have to be controlled at the few ppb level. The NPD Gamma experiment, a search for the small parity-violating {gamma}-ray asymmetry A{sub Y} in polarized cold neutron capture on parahydrogen, is one example. For the NPD Gamma experiment we developed a radio-frequency resonant spin rotator to reverse the neutron polarization in a 9.5 cm x 9.5 cm pulsed cold neutron beam with high efficiency over a broad cold neutron energy range. The effect of the spin reversal by the rotator on the neutron beam phase space is compared qualitatively to rf neutron spin flippers based on adiabatic fast ...

2008-08-01

279

Monte Carlo simulation and dosimetric verification of radiotherapy beam modifiers  

International Nuclear Information System (INIS)

Monte Carlo simulation of beam modifiers such as physical wedges and compensating filters has been performed with a rectilinear voxel geometry module. A modified version of the EGS4/DOSXYZ code has been developed for this purpose. The new implementations have been validated against the BEAM Monte Carlo code using its standard component modules (CMs) in several geometrical conditions. No significant disagreements were found within the statistical errors of 0.5% for photons and 2% for electrons. The clinical applicability and flexibility of the new version of the code has been assessed through an extensive verification versus dosimetric data. Both Varian multi-leaf collimator (MLC) wedges and standard wedges have been simulated and compared against experiments for 6 MV photon beams and different field sizes. Good agreement was found between calculated and measured depth doses and lateral dose profiles ...

2001-11-01

280

Versatile charged particle activation technique for the analysis of the noble metals  

Energy Technology Data Exchange (ETDEWEB)

The general usefulness of neutron activation analysis (NAA) for samples containing the platinum group elements (PGE) and Au, either as major or trace constituents, is discussed. Charged particle activation is shown to be a viable or complementary alternative. Proton (6-10 MeV) and alpha particle (9-15 MeV) beams, produced in a tandem Van de Graaff accelerator, have been established to be the most effective choice. By taking advantage of the Coulomb barrier effect and the fact that many charged particle induced reactions have relatively large threshold values, the same instrumental technique can be applied, with minor modifications, to a wide range of materials.

1982-01-01

281

Versatile charged particle activation technique for the analysis of the noble metals  

Energy Technology Data Exchange (ETDEWEB)

The general usefulness of neutron activation analysis (NAA) for samples containing the platinum group elements and Au, either as major or trace constituents, is discussed. Charged particle activation is shown to be a viable or complementary alternative. Proton (6-10 MeV) and alpha particle (9-15 MeV) beams, produced in a Tandem van de Graaff accelerator, have been established to be the most effective choice. By taking advantage of the Coulomb barrier effect and the fact that many charged particle induced reactions have relatively large threshold values, the same instrumental technique can be applied, with minor modifications, to a wide range of materials.

1983-01-01

282

Variable-dispersion electron spectrometer for the SCA/FEL  

International Nuclear Information System (INIS)

A variable-dispersion electron spectrometer is being installed for use by the Stanford Superconducting Accelerator in conjunction with its Free Electron Laser program. The system has been designed to operate with electron beam energies from 20 MeV to 200 MeV, with a maximum energy resolution of 0.01% FWHM. The maximum energy acceptance is approximately #+-# 5%, as determined by the bending magnet aperture. Resolution is controlled by adjusting the focal conditions at the entrance to a 90 degree bending magnet, while the dispersion is controlled by changing the magnitude and polarity of the field in a quadrupole magnet which immediately follows the bending magnet. 4 refs., 5 figs.

1989-06-01

283

Transverse Resistive Wall Wakefunction with Inductive Bypass  

CERN Document Server

Charged particle beams in circular accelerators couple with their surroundings through induced electromagnetic fields. This interaction can be described by so-called coupling impedances. In the frequency domain the impedance in connection with the bunch spectrum allows for stability analysis and estimates. However, for simulation codes one usually needs the wakefunction, the equivalent of the impedance in time domain. Recently the transverse impedance of a cylindrical pipe with arbitrary surface impedance was given by L. Vos. An expression for the wakefunction of this transverse resistive wall impedance with inductive bypass is derived here.

2003-01-01

284

Self-seeded injection-locked FEL amplifier  

Energy Technology Data Exchange (ETDEWEB)

A self-seeded free electron laser (FEL) provides a high gain and extraction efficiency for the emitted light. An accelerator outputs a beam of electron pulses to a permanent magnet wiggler having an input end for receiving the electron pulses and an output end for outputting light and the electron pulses. An optical feedback loop collects low power light in a small signal gain regime at the output end of said wiggler and returns the low power light to the input end of the wiggler while outputting high power light in a high signal gain regime.

1998-12-01

285

Radiation control aspects of the civil construction for a high power free electron laser (FEL) facility  

International Nuclear Information System (INIS)

The paper discusses some of the assumptions and methods employed for the control of ionizing radiation in the specifications for the civil construction of a planned free electron laser facility based on a 200 MeV, 5 mA superconducting recirculation electron accelerator. Consideration is given firstly to the way in which the underlying building configuration and siting aspects were optimized on the basis of the early assumptions of beam loss and radiation goals. The various design requirements for radiation protection are then considered, and how they were folded into an aesthetically pleasing and functional building. copyright 1997 American Institute of Physics.

1996-11-06

286

Properties of composite materials on the base of radiation-hardening binders and metal powders  

International Nuclear Information System (INIS)

Compositions (oligomers with suitable properties and Al, Fe, Cu, Ta, W powders) were hardured by the flux of accelerated electrons at 10 mA beam current and 1.5 MeV energy. Dielectric and mechanical properties of metal-filled polymeric compositions as well as their radioply sicl properties in SHF-range are studied. It is shown that the produced compositions belong tot he absorbing protective materials in which the protection effect is mainly achieved through the absorption losses. 6 refs.; 3 tabs.

287

Intermediate mass Higgs study at {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

We present the efficient technique to extract the signal of the intermediate mass Higgs boson from the backgrounds at future {gamma}{gamma} colliders. For a clear Higgs detection, it is important to fit the original electron accelerator energy depending on the Higgs mass, to set the polarization of the photon beams and to apply the efficient b quark tagging method. we demonstrate the extraction of information of Higgs parameters and the new physics from the observable physical quantities. It is clearly shown that a future {gamma}{gamma} collider will have a rich potential for study on the new physics, as well as the Higgs physics. (author).

1995-05-01

288

Intermediate mass Higgs study at #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We present the efficient technique to extract the signal of the intermediate mass Higgs boson from the backgrounds at future #gamma##gamma# colliders. For a clear Higgs detection, it is important to fit the original electron accelerator energy depending on the Higgs mass, to set the polarization of the photon beams and to apply the efficient b quark tagging method. we demonstrate the extraction of information of Higgs parameters and the new physics from the observable physical quantities. It is clearly shown that a future #gamma##gamma# collider will have a rich potential for study on the new physics, as well as the Higgs physics. (author).

1995-05-01

289

Interest of a two-dimensional matrix of detectors for the quality control of beams in static or dynamic mode; Interet d'une matrice bidimensionnelle de detecteurs pour le controle de qualite des faisceaux en mode statique ou dynamique  

Energy Technology Data Exchange (ETDEWEB)

A 2D matrix allows a fairly rapid verification of irradiation parameters transferred on computer processing equipment without expanding the dosimetry means to implement. Associated to 'Multicheck and Verisoft' software it will handle some of the regulatory recommendations of the A.F.S.S.A.P.S. for quality control of accelerators and ensure the traceability of testing carried out. (N.C.)

2007-11-15

290

INEEL BNCT research program. Annual report, January 1, 1996--December 31, 1996  

Energy Technology Data Exchange (ETDEWEB)

This report is a summary of the progress and research produced for the Idaho National Engineering and Environmental Laboratory (INEEL) Boron Neutron Capture Therapy (BNCT) Research Program for calendar year 1996. Contributions from the individual investigators about their projects are included, specifically, physics: treatment planning software, real-time neutron beam measurement dosimetry, measurement of the Finnish research reactor epithermal neutron spectrum, BNCT accelerator technology; and chemistry: analysis of biological samples and preparation of {sup 10}B enriched decaborane.

1997-04-01

291

INEEL Advanced Radiotherapy Research Program Annual Report 2001  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the major activities and accomplishments of the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2001. Applications of supportive research and development, as well as technology deployment in the fields of chemistry, radiation physics and dosimetry, and neutron source design and demonstration are described. Contributions in the fields of physics and biophysics include development of advanced patient treatment planning software, feasibility studies of accelerator neutron source technology for Neutron Capture Therapy (NCT), and completion of major modifications to the research reactor at Washington State University to produce an epithermal-neutron beam for NCT research applications.

2002-04-01

292

INEEL Advanced Radiotherapy Research Program Annual Report 2001  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the major activities and accomplishments of the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2001. Applications of supportive research and development, as well as technology deployment in the fields of chemistry, radiation physics and dosimetry, and neutron source design and demonstration are described. Contributions in the fields of physics and biophysics include development of advanced patient treatment planning software, feasibility studies of accelerator neutron source technology for Neutron Capture Therapy (NCT), and completion of major modifications to the research reactor at Washington State University to produce an epithermal-neutron beam for NCT research applications.

2002-04-30

293

HTSC devices fabricated by selective epitaxial growth  

International Nuclear Information System (INIS)

The use of a selective epitaxial growth technique for fabricating YBCO thin-film microstructures is described. No film post-deposition processing is required; hence damage to the structure is minimized. The technique is compatible with a passivation process to protect the structure without exposure to air. The microbridges, Josephson junctions and rf SQUIDs protected by an amorphous YBCO passivation have long lifetime even after severe accelerated aging tests. Rf SQUIDs fabricated by this technique show a significant reduction of low-frequency noise when operating in weak magnetic fields compared with SQUIDs fabricated by the conventional ion beam etching technique. (author)

1999-04-01

294

CyberKnife SRS: new technologies that enhance the treatment of cancer  

International Nuclear Information System (INIS)

The CyberKnife Robotic Radiosurgery System (Accuracy Incorporated, Sunnyvale, CA, USA) is used worldwide to treat tumors and neurological disorders anywhere in the body with sub-millimetre beam delivery accuracy. Accuracy has developed a number of new technologies in recent years to enhance the treatment of cancer patients. Such new technologies include a fast Monte Carlo Dose Calculation algorithm, Sequential Optimization dose planning, the IrisTM Variable Aperture Collimator, an 800 MU/min Linear Accelerator, and Optimized Path Traversal. These technologies enable physicists and physicians to plan treatments quickly and easily and deliver them with unrivalled accuracy and precision

2008-11-26

295

Billion particle linac simulations for future light sources  

Energy Technology Data Exchange (ETDEWEB)

In this paper we report on multi-physics, multi-billion macroparticle simulation of beam transport in a free electron laser (FEL) linac for future light source applications. The simulation includes a self-consistent calculation of 3D space-charge effects, short-range geometry wakefields, longitudinal coherent synchrotron radiation (CSR) wakefields, and detailed modeling of RF acceleration and focusing. We discuss the need for and the challenges associated with such large-scale simulation. Applications to the study of the microbunching instability in an FEL linac are also presented.

2008-09-25

296

Basic Science Beamline(TR104) at PEFP  

International Nuclear Information System (INIS)

PEFP(Proton Engineering Frontier Project) is developing beamlines for various application fields by using the high current 100MeV proton linear accelerator. Beamlines were characterized and categorized by the beam energy, average currents, and irradiation conditions. Among these beamlines the TR104 is designed for the basic science and the research of the aerospace. Before the construction and installation of beamlines, we try to practice and prepare the detail process of installation by the precedent study of TR104 beamline in KAERI site. By this work installation process was checked and confirmed for the same condition of the PEFP site

2010-10-01

297

The Hannover thermal noise experiment  

International Nuclear Information System (INIS)

To analyse the thermal noise of the pendulum mode of a suspended mirror, we interferometrically detect the differential movement of two mirrors suspended as multiple-stage pendulums. We present the set-up of this experiment and the current sensitivity, and also the different steps that we took in the past to increase the sensitivity, which include an auto alignment of the laser beam into the resonator eigenmode, changes of the seismic isolation system to more damping stages and higher moments of inertia and an intensive noise hunting.

2004-03-07

298

TPX Neutral Beam Injection System design  

International Nuclear Information System (INIS)

The existing Tokamak Fusion Test Reactor Neutral Beam system is proposed to be modified for long pulse operation on the Tokamak Physics Experiment (TPX). Day one of TPX will call for one TFTR beamline modified for 1000 second pulse lengths oriented co-directional to the plasma current. The system design will be capable of accommodating an additional co-directional and a single counter directional beamline. For the TPX conceptual design, every attempt was made to use existing Neutral Beam hardware, plant facilities, auxiliary systems, service infrastructure, and control systems. This paper describes the moderate modifications required to the power systems, the ion sources, and the beam impinged surfaces of the ion dumps, the calorimeters, the various beam scrapers, and the neutralizers. Also described are the minimal modifications required to the vacuum, cryogenic, and gas systems ...

1993-10-11

299

Large area electron beam pumped krypton fluoride laser amplifier  

International Nuclear Information System (INIS)

Nike is a recently completed multi-kilojoule krypton fluoride (KrF) laser that has been built to study the physics of direct drive inertial confinement fusion. This paper describes in detail both the pulsed power and optical performance of the largest amplifier in the Nike laser, the 60 cm amplifier. This is a double pass, double sided, electron beam-pumped system that amplifies the laser beam from an input of 50 J to an output of up to 5 kJ. It has an optical aperture of 60 cm x 60 cm and a gain length of 200 cm. The two electron beams are 60 cm high x 200 cm wide, have a voltage of 640 kV, a current of 540 kA, and a flat top power pulse duration of 250 ns. A 2 kG magnetic field is used to guide the beams and prevent self-pinching. Each electron beam is produced by its own Marx/pulse forming line system. The amplifier has been fully integrated into the Nike system and is used on a ...

300

Beam pattern diagnosis and adjustment guidance for cyclotron based on fuzzy relation  

Energy Technology Data Exchange (ETDEWEB)

An adjustment support system using computer for start-up operation of cyclotron is being developed in order to support operators who, using their experiences and intuition, tune up dozens of components to maximize beam efficiency. This paper describes a method of beam pattern diagnosis and adjustment guidance based on fuzzy relation as one function of the adjustment support system. The followings are the basic processes of this method. (1) The computer extracts features of beam pattern which correspond with operators' criteria. (2) The computer calculates causative possibility of each adjustment parameters by inverse operation of fuzzy relational equation, which formulates the relationship between criteria of beam pattern and adjustment parameters. (3) The computer displays those causative probabilities in a graphical manner as a operation guidance. Not only the ...

1990-08-01

301

Searching for the Neutrino Mixing Angle Theta-13 at Reactors  

CERN Document Server

Two neutrino mixing angles have been measured, and much of the neutrino community is turning its attention to the unmeasured mixing angle, $\\quq$, whose best limit comes from the reactor neutrino experiment CHOOZ.\\cite{bib:chooz} New two detector reactor neutrino experiments are being planned, along with more ambitious accelerator experiments, to measure or further limit $\\quq$. Here I will overview how to measure $\\quq$ using reactor neutrinos, mention some experiments that were considered and are not going forward, and review the current status of four projects: Double Chooz in France, Daya Bay in China, RENO in South Korea and Angra in Brazil. Finally I will mention how the neutrino observer can gauge progress in these projects two years from now as we approach the times corresponding to early estimates for new results.

2007-01-01

302

COSY synchrotron and storage ring for medium energy physics  

Energy Technology Data Exchange (ETDEWEB)

At present the cooler synchrotron COSY a synchrotron and storage ring for medium energy physics is being commissioned at Juelich. The construction of the ring was finished during September 1992. The cooler ring will deliver protons in the momentum range from 270 to 3300 MeV/c. The phase density of the circulating protons will be increased with electron cooling at injection and with stochastic cooling at momenta between 1500 and 3300 MeV/c. High luminosity internal experiments as well as high resolution external experiments will be possible. Details of the lattice, to match the different ion optical requirements for cooling, acceleration, internal experiments and ultra-slow extraction will be discussed. An overview of the performance of the ion sources, the injector cyclotron, the ring, the injection beamline are given. The realization status of the extraction beamlines to the external experimental area ...

1993-01-01

303

Dosimetry for Total Skin Electron Beam Therapy in Skin Cancer  

International Nuclear Information System (INIS)

Increasing frequency of skin cancer, mycosis fungoides, Kaposi sarcoma etc, it need to treatment dose planning for total skin electron beam (TSEB) therapy. Appropriate treatment planning for TSEB therapy is needed to give homogeneous dose distribution throughout the entire skin surface. The energy of 6 MeV electron from the 18 MeV medical linear accelerator was adapted for superficial total skin electron beam therapy. The energy of the electron beam was reduced to 4.2 MeV by a 0.5cmx90cmx180cm acryl screen placed in a feet front of the patient. Six dual field beam was adapted for total skin irradiation to encompass the entire body surface from head to toe simultaneously. The patients were treated behind the acryl screen plate acted as a beam scatterer and contained a parallel-plate shallow ion chamber for dosimetry and beam monitoring. ...

1992-06-01

304

Charge and fluence lifetime measurements of a dc high voltage GaAs photogun at high average current  

Energy Technology Data Exchange (ETDEWEB)

GaAs-based dc high voltage photoguns used at accelerators with extensive user programs must exhibit long photocathode operating lifetime. Achieving this goal represents a significant challenge for proposed high average current facilities that must operate at tens of milliamperes or more. This paper describes techniques to maintain good vacuum while delivering beam, and techniques that minimize the ill effects of ion bombardment, the dominant mechanism that reduces photocathode yield of a GaAs-based dc high voltage photogun. Experimental results presented here demonstrate enhanced lifetime at high beam currents by: (a) operating with the drive laser beam positioned away from the electrostatic center of the photocathode, (b) limiting the photocathode active area to eliminate photoemission from regions of the photocathode that do not support efficient beam delivery, (c) using a large ...

2011-04-01

305

Spin Duality on the Neutron (^3He)  

Energy Technology Data Exchange (ETDEWEB)

Thomas Jefferson National Accelerator Facility experiment E01-012 measured the 3He spin structure functions and virtual photon asymmetries in the resonance region in the momentum transfer range 1.0 < Q2 < 4.0 (GeV/c)2. Our date, when compared with existing deep inelastic scattering data, can be used to test quark-hadron duality in g1 and A1 for 3He and the neutron. Preliminary results for A{sub 1}{sup {sup 3}He} are presented, as well as some details about the experiment.

2007-02-01

306

Quality and availability of actinide isotopes from the All-Russian Scientific Research Institute of Experimental Physics in Arzamas-16  

International Nuclear Information System (INIS)

This paper describes the problems and capabilities of highly enriched actinide isotopes production by electromagnetic separation in the S-2 mass separator of VNIIEF. Isotope enrichment characteristics for uranium, plutonium, americium and curium isotopes, used in different nuclear physics experiments, and isotope contamination for single and double separations are presented. The capabilities for highly enriched "2"4"4Pu and "2"4"8Cm production for nuclear accelerator experiments and other applications are described, some details of the current and future programmes are given and the transport packaging is described. (orig.).

307

Researches on Plasma Physics and Controlled Fusion in IPP NSC KIPT  

International Nuclear Information System (INIS)

Recent results of experimental and theoretical investigations, carried out in the Institute of plasma Physics of the NSC KIPT, are presented in the report. The main problems of discussion are as follows: plasma confinement and heating in stellarators and electromagnetic traps; powerful quasi-steady-state plasma accelerators (QSPA); experiments relevant for ITER; fusion Plasma theory; methods of high temperature plasma diagnostics; plasma technology. The main prospects on the IPP investigators are discussed also.

2006-01-01

308

Power system stabilizer from accelerating power for Itauba power plant: Design and implementation; Projeto e implantacao de estabilizador de sistema de potencia derivado da potencia de aceleracao na Usina de Itauba  

Energy Technology Data Exchange (ETDEWEB)

This work presents the project and relates the implementation of a power system stabilizer in Itauba hydroelectric power plant, Brazil. Some forecasts and field experiments are also presented. 10 refs., 19 figs.

1992-12-31

309

New development of external-PIXE system using a differential pumping technique  

International Nuclear Information System (INIS)

A new external-PIXE system utilizing a differential pumping technique, which can completely protect the accelerator and vacuum pumps when the exit foil breaks down, has been developed. Applications to analyses of liquid and heavily-outgassing samples were successfully achieved. Also, experiments for evaluating the efficiency of the system were performed and results will be presented. (author)

1999-09-01

310

Physical model experiment for wave field measurements by means of laser Doppler vibrometer. Measurement of three components; Laser Doppler shindokei ni yoru butsuri model jikken. Hado sanseibun no kenshutsu  

Energy Technology Data Exchange (ETDEWEB)

In this experiment, a beam incident from an oblique direction is reflected by a spherical lens toward the direction of incidence. When the surface of a matter is vibrated by elastic waves, the spherical lens comes into a translation motion that accompanies the vibration. It follows accordingly that the vibration on the surface of the matter may be detected by sensing the spherical lens travelling speed. Three components of the vibration may be determined if beams are focused at one spot from three directions. Detection of the S-wave component by LDV (laser Doppler vibrometer) discloses the complicated wave field in a heterogeneous material, and this physical model experiment may be utilized in various fields of study. For instance, information about problems that may surface in the field work may be collected beforehand in a physical model experiment for developing an S-wave-aided ...

1997-05-27

311

Implementation of FFT convolution and multigrid superposition models in the FOCUS RTP system  

International Nuclear Information System (INIS)

In radiotherapy treatment planning, convolution/superposition algorithms currently represent the best practical approach for accurate photon dose calculation in heterogeneous tissues. In this work, the implementation, accuracy and performance of the FFT convolution (FFTC) and multigrid superposition (MGS) algorithms are presented. The FFTC and MGS models use the same 'TERMA' calculation and are commissioned using the same parameters. Both models use the same spectra, incorporate the same off-axis softening and base incident lateral fluence on the same measurements. In addition, corrections are explicitly applied to the polyenergetic and parallel kernel approximations, and electron contamination is modelled. Spectra generated by Monte Carlo (MC) modelling of treatment heads are used. Calculations using the MC spectra were in excellent agreement with measurements for many linear accelerator types. To speed up the calculations, a number of calculation techniques were ...

2000-04-01

312

Electron beam therapy at extended SSDs: an analysis of output correction factors for a Mitsubishi linear accelerator  

International Nuclear Information System (INIS)

The effects of extended source-to-surface distance (SSD) on the electron beam dose profiles were evaluated for various electron beam energies - 6, 9, 12, 15 and 20 MeV - and the accuracy of various output correction methods was analysed on a Mitsubishi linear accelerator using a radiation field analyser (RFA). The dose fall-off region of the central axis depth-dose curves was nearly independent for SSDs up to 120 cm where as in the build-up region, a marginal reduction of surface dose was observed, particularly for lower energies and for smaller field sizes. Effective SSDs and virtual source distances were evaluated for field sizes ranging from 5x5 to 15x15 cm"2 for various energies. Curve fitting was done with the measured outputs with various equations and coefficients were evaluated. The accuracy of the derived output correction factors by effective SSD, virtual source distance and curve-fit methods was assessed by ...

2002-09-21

313

Factoring Potential Accelerator Transmutation of Waste Demonstrations into Accelerator Production of Tritium Design Planning  

CERN Document Server

Factoring Potential Accelerator Transmutation of Waste Demonstrations into Accelerator Production of Tritium Design Planning

1998-01-01

317

Untersuchung von Bildqualitat und Genauigkeit der Dosisberechnung bei cone-beam-CT-Aufnahmen mit reduziertem Projektionsdatensatz (half scan, half fan) im Hinblick auf die Verwendbarkeit fur die adaptive Bestrahlungsplanung  

British Library Electronic Table of Contents (United Kingdom)

Subject of this study is the question of whether cone beam CT (CBCT) images with reduced projection data are suitable for use in adaptive radiation therapy (ART) treatment planning. For this purpose image quality and dose calculation accuracy depending on imaging modality were analysed. In this context, two CBCT-methods will be indicated having reduced projection data sets: Scans acquired with 200^o rotation angle in order to accelerate the CBCT process (half scan), or scans with an asymmetric cone beam and detector offset, used to enlarge the field-of-view (half fan). Methods: For three different CBCT-modes (On-Board-Imaging, Varian Medical Systems), two of them based on reduced projection data, and a conventional multidetector CT system, the main image quality parameters were studied. Tr...

2011-01-01

318

High-frequency electrostatic waves near Earth's bow shock  

International Nuclear Information System (INIS)

Electrostatic wave measurements from the Active Magnetospheric Particle Tracer Explorer Ion Release Module have been used to investigate the wave modes and their possible generation mechanisms in the Earth's bow shock and magnetosheath. It is demonstrated that electrostatic waves are present in the bow shock and magnetosheath with frequencies above the maximum frequency for Doppler-shifted ion acoustic waves, yet below the plasma frequency. Waves in this frequency range are tentatively identified as electron beam mode waves. Data from 45 bow shock crossings are then used to investigate possible correlations between the electrostatic wave properties and the near-shock plasma parameters. The most significant relationships found are anticorrelations with Alfven Mach number and electron beta. Mechanisms which might produce electron beams in the shock and magnetosheath are discussed in terms of the correlation study results. These mechanisms include ...

319

Evaluation of the increase of superficial dose due to thermoplastic immobilizing in radiotherapy; Avaliacao dos efeitos de superficializacao de dose por imobilizadores termoplasticos em radioterapia  

Energy Technology Data Exchange (ETDEWEB)

Perforated thermoplastic masks are used to provide patients immobilization. This procedure inserts a material in the path of the radiation beam, that attenuates and modifies the beam fluence and flatness. The present study evaluates the increase in skin dose as a result of using thermoplastic masks. Relative doses were measured on the surface of a solid water phantom, in the presence and absence of masks. These masks were stretched according to deformation patterns observed in clinical routine. The measurements were obtained with a plane-parallel chamber (Markus type 23343) and radiochromic film (EBT Gafchromic) for 6MV X-rays from a linear accelerator, and for a radiation beam from a cobalt therapy unit. The results showed that thermoplastic masks, whose thickness varied between 2 and 3 mm, increased the dose on the surface by a factor of 3. Due to the variations in the skin dose distribution, clinical ...

2010-07-01

320

Evaluation of the increase of superficial dose due to thermoplastic immobilizing in radiotherapy  

International Nuclear Information System (INIS)

Perforated thermoplastic masks are used to provide patients immobilization. This procedure inserts a material in the path of the radiation beam, that attenuates and modifies the beam fluence and flatness. The present study evaluates the increase in skin dose as a result of using thermoplastic masks. Relative doses were measured on the surface of a solid water phantom, in the presence and absence of masks. These masks were stretched according to deformation patterns observed in clinical routine. The measurements were obtained with a plane-parallel chamber (Markus type 23343) and radiochromic film (EBT Gafchromic) for 6MV X-rays from a linear accelerator, and for a radiation beam from a cobalt therapy unit. The results showed that thermoplastic masks, whose thickness varied between 2 and 3 mm, increased the dose on the surface by a factor of 3. Due to the variations in the skin dose distribution, clinical ...

2010-08-18

321

Challenges in fabrication of 180deg magnet chamber  

International Nuclear Information System (INIS)

180 deg magnet chamber is used in Folded Tandem Ion Accelerator for passage and 180 deg bending of ion beam. The chamber is placed between 180 deg terminal magnet (Electro-magnet), which is used for bending, and analysing the beams. Magnet with a particular magnetic field strength bends ions of only specified mass energy product through a precise path. There is also a space limitation in the direction of magnetic field. Both of them require the magnet chamber to be of a close tolerance. Accuracy of center distance between inlet and outlet port of the magnet chamber has to be at par with the concentricity of high energy and low energy beam line. To achieve this we started the fabrication of magnet chamber by following two methods: a) Circular rolling and bending of rectangular tube for 180 deg sector of magnet chamber b) Machining 180 deg sector in two half and welding. By first method we could not ...

2006-11-01

322

CERN Academic Training Programme 2008/2009  

CERN Multimedia

LECTURE SERIES 8, 9, 10 11 & 12 June 2009 11:00-12:00 - Main Auditorium, Bldg. 500 Scenarios and Technological Challenges for a LHC Luminosity Upgrade: Introduction to the LHC Upgrade Program and Summary of Physics Motivations After a general introduction to the motivations for a LHC upgrade, the lectures will discuss the beam dynamics and technological challenges of the increase of the LHC luminosity, and the possible scenarios. Items such as a stronger final focus with larger aperture magnets, crab cavities, electron cloud issues, beam-beam interaction, machine protection and collimation will be discussed.Monday 8 June 2009 Introduction to the LHC upgrade program - L. Evans Summary of Physics Motivations - M. Mangano Tuesday 9 June 2009 The Dectector Upgrade and the Requirements on the Upgrade Scenarios - M. Nessi Wednesday 10 June 2009 Scenarios for the LHC Luminosity Upgrade - F. Zimmermann Thursday 11 June 2009 Main ...

2009-01-01

323

Development of a high-current microwave ion source for proton linac application systems  

International Nuclear Information System (INIS)

A microwave hydrogen ion source was developed to improve reliability, and to increase operation time of proton linac application systems. The ion source needs no filament in the discharge chamber, which leads to better reliability and less maintenance time. The developed source produced a maximum hydrogen ion beam current of 70 mA (high current density of 360 mA/cm2, beam energy of 30 keV) with a 5 mm diam extraction aperture and 1.2 kW microwave power. The proton fraction was increased with an increase in rf power and reached around 90% at 1 kW. Measured 90% beam normalized emittance was 0.4 #pi# mm mrad. Rise times of rf power and beam current to 90% of the final values were about 30 and 35 #mu#s, respectively, at a pulse operation mode with 400 #mu#s pulse width and 100 Hz repetition rate. The dynamic range of beam currents was enlarged (3-63 mA) in the pulse mode with a modified ...

2004-05-01

324

Paul Trap Simulator Experiment to Model Intense Beam Propagation in Alternating-gradient Transport Systems  

Energy Technology Data Exchange (ETDEWEB)

The results presented here demonstrate that the Paul Trap Simulator Experiment (PTSX) simulates the propagation of intense charged particle beams over distances of many kilometers through magnetic alternating-gradient (AG) transport systems by making use of the similarity between the transverse dynamics of particles in the two systems. Plasmas have been trapped that correspond to normalized intensity parameters s = wp2 (0)/2wq2 * 0.8, where wp(r) is the plasmas frequency and wq is the average transverse focusing frequency in the smooth-focusing approximation. The measured root-mean-squared (RMS) radius of the beam is consistent with a model, equally applicable to both PTSX and AG systems that balances the average inward confining force against the outward pressure-gradient and space-charge forces. The PTSX device confines one-component cesium ion plasmas for hundreds of milliseconds, which is equivalent to over 10 km of ...

2004-01-29

325

Behavior of the positron beam of the Super-ACO storage ring in response to a modification of the RF frequency for free-electron laser experiments  

International Nuclear Information System (INIS)

The macrotemporal structure of the Super-ACO Storage ring free-electron laser (FEL) can be either continuous, pulsed, or chaotic, and can present some rapid fluctuations. The temporal evolution of a storage ring FEL involves both the longitudinal motion of the positron beam (especially the synchrotron oscillations) and the FEL dynamics, as in a coupled system. Studies on the dynamics of the positron beam are performed here, in the goal to have a stable source for FEL applications, and to determine the conditions for a stable Q-switching experiment. The employed method is to study the influence of a controlled change of the radio frequency (RF) (modulation or frequency jump) on the beam. A simple theoretical model taking into account the perturbed RF system is presented to help the understanding of the experimental data. The different methods of measurement are described. Then, the results are given for ...

326

Effect of helium and hydrogen production on irradiation hardening of F82H steel irradiated by ion beams  

International Nuclear Information System (INIS)

Effects of helium and hydrogen production on irradiation hardening of martensitic steel F82H (Fe-8Cr-2W-0.2V-0.04Ta-0.1C) were examined by dual or triple beam experiments. The effects of tempering and cold working were also examined. The irradiations were performed at about 500degC to 50 dpa under simultaneous dual beams of 10.5 MeV Fe"3"+ and 1.05 MeV He"+ or triple beams of those and 380 keV H"+ ions. The value of appm-He/dpa for the dual ion beams was about 15, and the values of appm-He/dpa and appm-H/dpa for the triple ion beams were 15 and 15 (or 150), respectively. The hardness of the irradiated specimens measured at room temperature using a micro indentation after the irradiations. Irradiation softening and hardening was observed in F82H-std, F82H+20%CW and a non-tempered F82H steels irradiated at about 500degC to 18 and 50 dpa, respectively, by dual ion ...

2007-06-01

327

European facilities for accelerator neutrino physics: perspectives for the decade to come  

CERN Document Server

Very soon a new generation of reactor and accelerator neutrino oscillation experiments - Double Chooz, Daya Bay, Reno and T2K - will seek for oscillation signals generated by the mixing parameter theta_13. The knowledge of this angle is a fundamental milestone to optimize further experiments aimed at detecting CP violation in the neutrino sector. Leptonic CP violation is a key phenomenon that has profound implications in particle physics and cosmology but it is clearly out of reach for the aforementioned experiments. Since late 90's, a world-wide activity is in progress to design facilities that can access CP violation in neutrino oscillation and perform high precision measurements of the lepton counterpart of the Cabibbo-Kobayashi-Maskawa matrix. In this paper the status of these studies will be summarized, focusing on the options that are best suited to exploit existing European facilities (firstly ...

2009-01-01

328

Adaptation of an air-dielectric RF cable for use as an oil-filled high voltage pulse transmission line  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the specifications, conceptual design, prototype testing and operating experience of an oil-filled high voltage pulse transmission cable adapted from commercially available air-dielectric RF components. Lawrence Livermore National Laboratory's Advanced Test Accelerator (ATA) requires a method of transmitting 250kV, 70 nanosecond pulses from the power conditioning equipment to the accelerator. The oil-filled cable approach was chosen over alternative concepts because of its high voltage holding capacity, long life and flexibility. The criteria for cable and connector design are discussed. The results of prototype testing and performance of the final design are presented.

1984-11-01

329

Electron beam therapy in carcinoma of the buccal mucosa  

Energy Technology Data Exchange (ETDEWEB)

Electron beam therapy has often been used for radiation therapy of carcinomas of the buccal mucosa, though side effects, including stomatitis and dermatitis, are known to exist. We experimented using the additional back scatter and transit with the phantom under a lead plate within the irradiation field, in order to better focus the dose on the target volume moreover, we fabricated a mouthpiece fitted with a lead plate shaped to the target volume, and with respect to the influence of the mouthpiece on stomatitis and dermatitis, obtained good clinical results. (author).

1990-10-01

330

Electron beam therapy in carcinoma of the buccal mucosa  

International Nuclear Information System (INIS)

Electron beam therapy has often been used for radiation therapy of carcinomas of the buccal mucosa, though side effects, including stomatitis and dermatitis, are known to exist. We experimented using the additional back scatter and transit with the phantom under a lead plate within the irradiation field, in order to better focus the dose on the target volume moreover, we fabricated a mouthpiece fitted with a lead plate shaped to the target volume, and with respect to the influence of the mouthpiece on stomatitis and dermatitis, obtained good clinical results. (author).

331

Absolute, cascade-free cross sections for the "2S#->#"2P transition in Zn"+ using electron-energy-loss and merged-beams methods  

International Nuclear Information System (INIS)

Absolute, cascade-free excitation cross sections in an ion have been measured for the resonance "2S#->#"2P transition in Zn"+ using electron-energy-loss and merged electron-ion beams methods. Measurements were carried out at electron energies of below threshold to 6 times threshold. Comparisons are made with 2-, 5-, and 15-state close-coupling and distorted-wave theories. There is good agreement between experiment and the 15-state close-coupling cross sections over the energy range of the calculations.

332

Proton G{sub E}/G{sub M} from beam-target asymmetry  

Science.gov (United States)

The ratio of the proton's electric to magnetic form factor, G{sub E}/G{sub M}, can be extracted in elastic electron-proton scattering by measuring cross sections, beam-target asymmetry, or recoil polarization. Separate determinations of G{sub E}/G{sub M} by cross sections and recoil polarization observables disagree for Q{sup 2}>1 (GeV/c){sup 2}. Measurement by a third technique might uncover an unknown systematic error in either of the previous measurements. The beam-target asymmetry has been measured for elastic electron-proton scattering at Q{sup 2} = 1.51 (GeV/c){sup 2} for target spin orientation aligned perpendicular to the beam momentum direction. This is the largest Q{sup 2} at which G{sub E}/G{sub M} has been determined by a beam-target asymmetry experiment. The result, {mu}G{sub E}/G{sub M}=0.884{+-}0.027{+-}0.029, is compared to previous world data.

2006-09-15

333

Strong laser fields as a probe for fundamental physics  

CERN Document Server

Upcoming high-intensity laser systems will be able to probe the quantum-induced nonlinear regime of electrodynamics. So far unobserved QED phenomena such as the discovery of a nonlinear response of the quantum vacuum to macroscopic electromagnetic fields can become accessible. In addition, such laser systems provide for a flexible tool for investigating fundamental physics. Primary goals consist in verifying so far unobserved QED phenomena. Moreover, strong-field experiments can search for new light but weakly interacting degrees of freedom and are thus complementary to accelerator-driven experiments. I review recent developments in this field, focusing on photon experiments in strong electromagnetic fields. The interaction of particle-physics candidates with photons and external fields can be parameterized by low-energy effective actions and typically predict characteristic optical signatures. I ...

2008-01-01

334

State of the art simulations of magnicon  

International Nuclear Information System (INIS)

The magnicon is a highly attractive candidate to be the RF source for a future multi-Tev linear collider. Physical models and computer codes have been developed which can provide start-to-end self-consistent simulations of a magnicon, including precise simulations of the high-convergence electron gun, RF-system, magnetic system, and beam collector. The 3-D beam dynamics simulations include realistic fields, finite beam size and transverse space charge effects. The codes allow one to provide steady-state simulations of the entire tube, so as to evaluate transient process of magnicon excitation, parasitic mode self-excitation, stability analysis, and tolerance analysis. The results of the simulations are found to be in good agreement with magnicon experiments. A brief description of the physical models and simulation codes employed will be given.

2002-12-12

335

Neutrino tagging through secondary beam scraping  

CERN Document Server

We discuss an experimental technique aimed at tagging electron neutrinos in multi-GeV artificial sources on an event-by-event basis. It exploits in a novel manner calorimetric and tracking technologies developed in the framework of the LHC experiments and of rare kaon decay searches. The setup is based on an instrumented decay tunnel equipped with tagging units that intercept secondary and tertiary leptons from the bulk of undecayed pi+ and protons. We show that the taggers are able to reduce the nue contamination originating from K_e3 decays by about one order of magnitude. Only a limited suppression (~60%) is achieved for nue produced by the decay-in-flight of muons; for moderate beam powers, similar performance as for K_e3 can be reached supplementing the tagging system with an instrumented beam dump.

2010-01-01

336

Growth mechanisms and thermal stability of ion-beam-induced epitaxial Pd/sub 2/Si films  

Energy Technology Data Exchange (ETDEWEB)

Growth mechanisms and thermal stability of ion-beam-induced epitaxial Pd/sub 2/Si films are investigated using Rutherford backscattering and channelling techniques. Epitaxial growth of Pd/sub 2/Si films was observed at room temperature by argon ion implantation into as-deposited Pd/Si(111) structures and furnace-annealed Pd/sub 2/Si(polycrystalline)/Pd/sub 2/Si(epitaxial)/Si(111) structures. Some additional experiments to check the growth mechanisms are also presented, in which the implantation energies, substrate orientations and dose rates were changed. Finally, the stability of the ion-beam-induced epitaxial Pd/sub 2/Si films on subsequent furnace annealing is studied.

1982-06-11

337

Growth meachnisms and thermal stability of ion-beam-induced epitaxial Pd/sub 2/Si films  

Energy Technology Data Exchange (ETDEWEB)

Growth mechanisms and thermal stability of ion-beam-induced epitaxial Pd/sub 2/Si films are investigated using Rutherford backscattering and channelling techniques. Epitaxial growth of Pd/sub 2/Si films was observed at room temperature by argon ion implantation into as-deposited Pd/Si(111) structures and furnace-annealed Pd/sub 2/Si(polycrystalline)/Pd/sub 2/Si(epitaxial)/Si(111) structures. Some additional experiments to check the growth mechanisms are also presented, in which the implantation energies, substrate orientations and dose rates were changed. Finally, the stability of the ion-beam-induced epitaxial Pd/sub 2/Si films on subsequent furnace annealing is studied.

1982-06-11

338

Current drive and heating systems based on high-energy (1- to 3-MeV) negative ion beams  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a concept for a current drive system based on negative ions with beam energy > 1 MeV. Preliminary physics calculations show that the core current necessary for stability enhancement can best be achieved by beams with energy ranging from 1 to 4 MeV. Further study and experiments will better define the optimum energy. Work under way at Oak Ridge National Laboratory (ORNL) and at collaborating institutes in Canada and the Federal Republic of Germany is defining a system, its elements, a configuration and operational scenarios deemed appropriate for such devices as ITER and other future steady-state tokamaks, and the requisite research and development to provide such a system. 7 refs., 2 figs.

1988-01-01

339

Apparatus for producing controlled positive or negative corona discharge for semiconductor materials processing  

Energy Technology Data Exchange (ETDEWEB)

An apparatus capable of producing current or voltage controlled positive and negative ion beams in 1-atm oxidizing and nonoxidizing ambients between 25/sup 0/ and 950 /sup 0/C is presented. The apparatus utilizes a point-to-plane corona discharge in the gas phase. Room-temperature experiments revealed that the small differences in ion beam shape between the two polarities is primarily due to the difference in applied voltage required to produce the same current for the two polarities. Due to increased ion mobility and decreased threshold voltage at higher temperatures, a slight broadening of the ion beam current-density profiles for both positive and negative ions is predicted.

1984-09-01

340

Monte Carlo evaluation of the AAA treatment planning algorithm in a heterogeneous multilayer phantom and IMRT clinical treatments for an Elekta SL25 linear accelerator  

International Nuclear Information System (INIS)

The Anisotropic Analytical Algorithm (AAA) is a new pencil beam convolution/superposition algorithm proposed by Varian for photon dose calculations. The configuration of AAA depends on linear accelerator design and specifications. The purpose of this study was to investigate the accuracy of AAA for an Elekta SL25 linear accelerator for small fields and intensity modulated radiation therapy (IMRT) treatments in inhomogeneous media. The accuracy of AAA was evaluated in two studies. First, AAA was compared both with Monte Carlo (MC) and the measurements in an inhomogeneous phantom simulating lung equivalent tissues and bone ribs. The algorithm was tested under lateral electronic disequilibrium conditions, using small fields (2x2 cm"2). Good agreement was generally achieved for depth dose and profiles, with deviations generally below 3% in lung inhomogeneities and below 5% at interfaces. However, the effects of attenuation and ...

2007-05-01

341

The addition of trim coils to the Tandem Mirror Experiment magnet system to improve the magnetic field mapping  

International Nuclear Information System (INIS)

The mapping of the magnetic flux bundle from the center cell to the Plasma Potential Control plates (PPC) on the end fan of the Tandem Mirror Experiment Upgrade (TMX-U), was improved by the addition of trim coils (12,000 amp-turns) on each side of each end fan next to the pump beam magnetic shields. The coils' axes are oriented perpendicular to the machine centerline. These coils made the necessary corrections to the field-line mapping, while keeping the field in the nearby pump beam magnetic shield below the saturation threshold. This paper briefly describes the problem, discusses the design as it evolved, and presents the results of the field testing. A brief description of the improvement in the machine performance is also included.

342

Muon physics with the proposed Pulsed Lepton Source at LAMPF  

Energy Technology Data Exchange (ETDEWEB)

The Pulsed Lepton Source (PLS) project opens some exciting possibilities for muon and neutrino physics . The PLS would use the 0.25 4s proton pulses from the upgraded Proton Storage Ring (PSR) at LAMPF to create short, intense bursts of muons and neutrinos. The neutrino beam would be used for a few fundamentally important weak interaction physics experiments. The muon beams would find a wide variety of applications in both fundamental and applied'' muon physics areas. After a brief discussion of the physical layouts of the PSR and the proposed PLS in Sec. 2 and muon area in Sec. 3, we note some of the muon physics experiments and areas that could advantageously be addressed at the PLS in Secs. 4 and 5, and conclude in Sec. 6.

1992-01-01

343

Ion temperature anisotropy in high power helium neutral beam fuelling experiments in JET  

Energy Technology Data Exchange (ETDEWEB)

During helium beam fuelling experiments in JET, distinctive anisotropic features have been observed in the velocity distribution function describing both fast and thermal alpha particle populations. During the initial fuelling phase the central helium ion temperature observed perpendicular to the magnetic field is higher than the central electron temperature, while the central helium ion temperature observed parallel to the magnetic field is lower than or equal to the central electron temperature. In order to verify temperature measurements of both perpendicular and parallel lines of sight, other independent methods of deducing the ion temperature are investigated: deuterium ion temperature, deuterium density, comparison with neutron rates and profiles (influence of a possible metastable population of helium). 6 refs., 7 figs.

1994-07-01

344

Instabilities in Focused Ion Beam-patterned Au nanowires  

British Library Electronic Table of Contents (United Kingdom)

Focused Ion Beam (FIB) technology has become an indispensable enabling tool for micro nano fabrications. One important application is to use FIB for patterning conducting nanowires of metals down to a few tens of nanometre for applications such as interconnects, heaters and temperature nanosensors. A series of experiments on Au nanowires fabricated by FIB on SixNy membrane show that nanowires with width 50nm have structural instabilities. These are liquid like and first show-up as undulations in nanowire width with clearly defined wave lengths. For smaller widths (20nm) the instabilities grow and the wires eventually break-up into spherical balls. Further experiments show that the nanowires can be made stable to smaller widths by the use of a Cr underlayer to enhance surface wetting. The o...

2011-01-01

345

Investigations of Pulsed Plasma Streams Generated by 'Prosvet' device Operated with Different Gases  

International Nuclear Information System (INIS)

The paper presents the investigations of plasma streams generated by pulsed plasma gun 'Prosvet' operated with different gases: krypton (m=84) and helium (m=4). Contour parameters of working gas spectral lines (full intensities and half-widths) are used for determination of spatial distributions of the electron density and temperature. Temporal distributions of the spectral lines intensities (both neutrals and ions of working gas), impurity spectral lines and continuum intensities are analyzed. Plasma stream velocity was estimated by time-of-flight method between two monochromators (MUM) connected with photo-multiplier. longitudinal distributions of the plasma pressure for different time moments and varied distances from the accelerator output have been used for investigation of the plasma stream dynamics and study the plasma compression in the focus region for different operational regimes of plasma accelerator. ...

2006-01-01

346

First Result of Induction Acceleration in the KEK Proton Synchrotron  

CERN Document Server

First Result of Induction Acceleration in the KEK Proton Synchrotron

2005-01-01

347

A Bragg curve ionization chamber for acceleration mass spectrometry  

CERN Document Server

A Bragg curve ionization chamber for acceleration mass spectrometry

1985-01-01

348

Vibration experiment for a three-loop PWR reactor building  

International Nuclear Information System (INIS)

Forced vibration experiment has been conducted for the reactor building of Sendai Unit 1 nuclear power plant. The beam vibrational behaviors of the outer shielding building and the internal concrete structure have been observed by using a 50 tf vibration for low frequency region, and a 10 tf vibration for high frequency region, respectively. The outline of the experimental methods, the data handling system and the major results of experiment are described. The experimental results were simulated by an analytical model. The proper vibrational frequency and the vibration modes obtained by the analysis were compared with those obtained by the experiment. By these comparison, the adequacy of the analytical method employed for the design was confirmed. (Aoki, K.).

1983-01-01

349

Clinical implementation of a convolution based algorithm for 3D treatment planning  

International Nuclear Information System (INIS)

Purpose/Objective: With the advent of computed tomography and magnetic resonance imaging, the three dimensional representation of the patient anatomy has become an invaluable resource for better diagnosis and delineation of the target volume and sensitive structures in radiation therapy. Although the therapeutic linear accelerator industry has made available highly sophisticated equipment, the aggressiveness in dose prescription and delivery has to be complimented by accurate dose computation methods. We have adopted a convolution/superposition algorithm for the calculation of absolute dose that fully accounts for the external shape and internal structure of the patient for photon treatment radiotherapy. In this paper, we will discuss the principles of the convolution algorithm and we will show how the computed dose compares to clinically relevant treatment techniques. Materials and Methods: A computer controlled data acquisition system and a water tank where used ...

350

Smith-Purcell free-electron laser  

International Nuclear Information System (INIS)

The term Smith-Purcell free electron laser can be employed generally to describe any coherent radiation source in which a diffraction grating is used to couple an electron beam with the electromagnetic field. To date, most practical developments of this concept have focused on devices which operate in the millimeter spectral regime. In this paper construction of a Smith-Purcell free-electron laser operating in the far-infrared (FIR) region using a novel resonator cavity design and the electron beam from a low energy (0.5-5 MeV) radio-frequency accelerator will be discussed. A tunable source in this region would have many applications and since the beam energy is low, the small size and low overall cost of such a device would make it a laboratory instrument. Current projects which are progressing towards developing a FIR source are the programs at Stanford and CREOL. Both of these projects are using ...

1995-08-21

351

Industrial applications of the Jefferson Lab high-power free-electron laser  

International Nuclear Information System (INIS)

In partnership with the US Navy, high-technology corporations, and research universities, Jefferson Lab is building a superconducting radio-frequency (SRF) accelerator-driven free-electron laser (FEL) and is outfitting an FEL user facility. This first fourth-generation light source - a 1 kW, 3 #mu#m infrared (IR) laser - is the first step in a program to develop high-average-power SRF-based IR and ultraviolet (UV) FELs for multiple manufacturing applications as well as for defense-related applied research and basic scientific research. This initial FEL will be driven by a 42 MeV, 5 m A recirculating SRF linac similar to the much larger SRF linac in Jefferson Lab's 4 GeV, 200 #mu#A Continuous Electron Beam Accelerator Facility (CEBAF). The FEL is expected to demonstrate 75% energy recovery. Its linac will be cooled by the existing CEBAF cryogenic system. At Jefferson Lab, an infrastructure of facilities and people already ...

1998-09-02

352

EB-curing of coatings on wood composite boards  

International Nuclear Information System (INIS)

The industrial radiation processing using low energy electron beam (EB) accelerators lower than 300 keV offers high speed, safe technologies for the chemical conversion of thin layer coatings. Because of the nonselective mode of initiating chain reaction polymerization involving free radicals in synthetic coating layers and suitable substrates, the EB curing of the coatings on woods and papers has particular advantage. Hungary decided to start an up-to-date EB line to process cement-bound (CB) wood chipboards with pigmented acrylic coatings. The CB wood chipboards contain more than 60 % of portland cement and up to 40 % of wood particles. They are produced as large boads of 6 - 16 mm thickness. In their fireproof character and other aspects, they are similar to asbestos-cement boards without containing carcinagenic asbestos, and are stable against moisture and atmospheric influences. EB-cured acrylate coating improved further those properties, ...

1988-10-01

353

Design of APhF-IH Linac for a Compact Medical Accelerator  

CERN Document Server

The design of a small injection linac for a compact medical synchrotron is discussed. The linac design is based on interdigital H-type (IH) drift-tube structure with alternative phase focusing (APhF). A high acceleration rate and an absence of magnetic lenses inside drift-tubes reduce the cost and length of APhF-IH linac in comparison with HIMAC linac based on Alvarez structure with magnet quadrupoles inside drift-tubes. To reduce effects of emittance growth, the RFQ structure is used in front of the APhF linac. In such linac layout, the current transmission of a carbon beam can reach up to 90-100%. In this report, the basic parameters of whole linac are presented, while the design of APhF structure is considered in details. Two reference designs of 4 MeV/u 200 MHz APhF linacs with different voltage distributions along the whole tank have been generated and analyzed numerically. For the first design, a constant voltage distribution along the ...

2003-01-01

354

Bendable Focusing X-Ray Optics for the ALS and the LCLS/FEL: Design, Metrology, and Performance  

Energy Technology Data Exchange (ETDEWEB)

We review the recent development of bendable x-ray optics used for focusing of beams of soft and hard x-rays at the Advanced Light Source (ALS) at Lawrence Berkeley National Laboratory and at the Linac Coherent Light Source (LCLS) x-ray free electron laser (FEL) at the Stanford Linear Accelerator Center (SLAC) National Accelerator Laboratory. For simultaneous focusing in the tangential and sagittal directions, two elliptically cylindrical reflecting elements, a Kirkpatrick-Baez (KB) pair, are used. Because fabrication of elliptical surfaces is complicated, the cost of directly fabricated tangential elliptical cylinders is often prohibitive. Moreover, such optics cannot be easily readjusted for use in multiple, different experimental arrangements, e.g. at different focal distances. This is in contrast to flat optics that are simpler to manufacture and easier to measure by conventional interferometry. The tangential figure of ...

2010-06-02

355

Particle physics -- Future directions  

Energy Technology Data Exchange (ETDEWEB)

Wonderful opportunities await particle physics over the next decade, with the coming of the Large Hadron Collider at CERN to explore the 1-TeV scale (extending efforts at LEP and the Tevatron to unravel the nature of electroweak symmetry breaking) and many initiatives to develop our understanding of the problem of identity: what makes a neutrino a neutrino and a top quark a top quark. Here I have in mind the work of the B factories and the Tevatron collider on CP violation and the weak interactions of the b quark; the wonderfully sensitive experiments at Brookhaven, CERN, Fermilab, and Frascati on CP violation and rare decays of kaons; the prospect of definitive accelerator experiments on neutrino oscillations and the nature of the neutrinos; and a host of new experiments on the sensitivity frontier. We might even learn to read experiment for clues about the dimensionality of ...

2001-11-29

356

The interaction of fast N"+_2 ions with a Ni(111) surface  

International Nuclear Information System (INIS)

In the context of sputtering experiments, studying the back-scattering of fast ion beams is a useful way to study inelastic ion-surface interactions, since then the trajectories and energies of the particles are well defined. This same argument holds for the scattering of fast molecular ions. We give a short account of our experiment where N"+_2 was scattered from a Ni(111) surface. The measured energy distributions of scattered N atoms are discussed with regard to vibrational and rotational energy transfer during scattering. (G.Q.).

1986-02-01

357

Study of d+#ALPHA# system in kinematically complete experiment at 27,2 MeV #alpha#-particle energy  

International Nuclear Information System (INIS)

The "2H(#alpha#,p#alpha#)n reaction was investigated in a kinematically complete experiment with a #alpha#-beam at energy 27.2 MeV.The "5He excited state was observed and its parameters were determinate.Coincidence spectra were fitted by contribution of sequential decay through the "5He ground and excited states.The best agreement with the data was obtained assuming the following "5He excited state parameters: E_a_n=2.8 MeV #GAMMA#=2.5 MeV.

358

Single event effects in the pixel readout chip for BTeV  

Energy Technology Data Exchange (ETDEWEB)

In future experiments the readout electronics for pixel detectors is required to be resistant to a very high radiation level. In this paper we report on irradiation tests performed on several preFPIX2 prototype pixel readout chips for the BTeV experiment exposed to a 200 MeV proton beam. The prototype chips have been implemented in commercial 0.25 {micro}m CMOS processes following radiation tolerant design rules. The results show that this ASIC design tolerates a large total radiation dose, and that radiation induced Single Event Effects occur at a manageable level.

2001-12-07

359

Grid-controlled plasma cathodes  

International Nuclear Information System (INIS)

Experiments are described on a plasma cathode with biased grids to prevent entry of ions into the electron extraction gap. The cathode has potential applications to the generation of high-current pulsed electron beams. Operation at 20 A/cm"2 is theoretically possible. The source combines the low average power consumption of a plasma cathode with many of the attractive features of thermionic cathodes, such as space-charge-limited extractor gap electron flow, fast turn-on, and no diode closure. Initial experiments are reported at the 2 A/cm"2 level for pulse lengths to 160 #mu#s.

360

Consideration of some fundamental erosion processes encountered in hypervelocity electromagnetic propulsion  

Energy Technology Data Exchange (ETDEWEB)

Experimental and theoretical research has been conducted jointly at the Livermore and Los Alamos National laboratories on dc electromagnetic railgun Lorentz accelerators. Pellets weighing a few grams to tens of grams have been launched at velocities up to better than 11 km/s. The research is addressed to attaining repeated launches of samples at hypervelocity in target impact experiments. In these experiments, shock-induced pressures in the tens of megabars range are obtained for high pressure equation-of-state research. Primary energy sources of the order of several hundred kJ to a MJ and induction currents of the order of 1 or more MA are necessary for these launches. Erosion and deformation of the conductor rails and the accelerated sample material are continuing problems. The heating, stress, and erosion resulting from simultaneous imposition of rail induction current, dense plasma (armature) ...

1982-09-30

361

VLEPP based photon linear collider 100x100 GeV with ultimate luminosity  

Energy Technology Data Exchange (ETDEWEB)

The possible parameters of a photon linear collider at its ultimate luminosity, based on the VLEPP physics and technology V.E. Balakin et al., Proc. 6th Nat. Conf. on Accelerators, Dubna, 1978; V.E. Balakin, Proc. 4th Int. Workshop on Next Generation Linear Colliders, Garmisch, 1992, are presented. At a photon energy of 100x100 GeV the maximum achievable luminosity is about 1x10{sup 36} cm{sup -2} s{sup -1}. Beam parameters, luminosity characteristics, and ways to reduce the background are considered as well. ((orig.)).

1995-02-01

362

TLA monitoring of an anodic protection system  

Energy Technology Data Exchange (ETDEWEB)

Corrosion is a materials degradation process that engineering personnel in the pulp and paper industry have had to accept as unavoidable to some degree, due to aggressive processing conditions prevalent in paper mills. The increasing incidence of corrosion-related failures in plant and equipment has resulted in the introduction of new techniques to monitor corrosion rates, since many of the more traditional methods do not provide data that is either recent or accurate enough. Thin layer activation (TLA) is a new corrosion monitoring technique which has recently been employed to measure corrosion trends inside a continuous pulp digester. With TLA a surface is irradiated by a particle beam from a nuclear accelerator, causing it to be labelled with an accurate depth profile and low level radioactivity. By monitoring this activity, it is possible to calculate how much of the surface has been removed by corrosion. 14 refs., 7 figs., 4 tabs.

1992-03-01

363

TLA monitoring of an anodic protection system  

International Nuclear Information System (INIS)

Corrosion is a materials degradation process that engineering personnel in the pulp and paper industry have had to accept as unavoidable to some degree, due to aggressive processing conditions prevalent in paper mills. The increasing incidence of corrosion-related failures in plant and equipment has resulted in the introduction of new techniques to monitor corrosion rates, since many of the more traditional methods do not provide data that is either recent or accurate enough. Thin layer activation (TLA) is a new corrosion monitoring technique which has recently been employed to measure corrosion trends inside a continuous pulp digester. With TLA a surface is irradiated by a particle beam from a nuclear accelerator, causing it to be labelled with an accurate depth profile and low level radioactivity. By monitoring this activity, it is possible to calculate how much of the surface has been removed by corrosion. 14 refs., 7 figs., 4 tabs.

364

Reversed light-dark cycle and cage enrichment effects on ethanol-induced deficits in motor coordination assessed in inbred mouse strains with a compact battery of refined tests  

British Library Electronic Table of Contents (United Kingdom)

The laboratory environment existing outside the test situation itself can have a substantial influence on results of some behavioral tests with mice, and the extent of these influences sometimes depends on genotype. For alcohol research, the principal issue is whether genotype-related ethanol effects will themselves be altered by common variations in the lab environment or instead will be essentially the same across a wide range of lab environments. Data from 20 inbred strains were used to reduce an original battery of seven tests of alcohol intoxication to a compact battery of four tests: the balance beam and grip strength with a 1.25g/kg ethanol dose and the accelerating rotarod and open-field activation tests with 1.75g/kg. The abbreviated battery was then used to study eight inbred str...

2011-01-01

365

Monte Carlo treatment planning for photon and electron beams  

British Library Electronic Table of Contents (United Kingdom)

During the last few decades, accuracy in photon and electron radiotherapy has increased substantially. This is partly due to enhanced linear accelerator technology, providing more flexibility in field definition (e.g. the usage of computer-controlled dynamic multileaf collimators), which led to intensity modulated radiotherapy (IMRT). Important improvements have also been made in the treatment planning process, more specifically in the dose calculations. Originally, dose calculations relied heavily on analytic, semi-analytic and empirical algorithms. The more accurate convolution/superposition codes use pre-calculated Monte Carlo dose "kernels" partly accounting for tissue density heterogeneities. It is generally recognized that the Monte Carlo method is able to increase accuracy even furt...

2007-01-01

366

ITER baffle module small-scale mock-ups: first wall thermo-mechanical testing results  

International Nuclear Information System (INIS)

The EU-home team is in charge of the R and D related to the ITER baffle first wall. Five small-scale mock-ups, using Be, CFC and W tiles and different armour/heat-sink material joints under development, have been fabricated and thermomechanically tested in FE200 (Le Creusot) and JUDITH (Juelich) electron beam facilities. The small-scale mock-ups have been submitted to thermo-mechanical fatigue tests (up to failure using accelerating techniques). The objective was to determine the performances of the armour material joints under high heat flux cycles. (orig.)

1998-09-01

367

High power testing of a 17 GHz photocathode RF gun  

Energy Technology Data Exchange (ETDEWEB)

The physics and technological issues involved in high gradient particle acceleration at high microwave (RF) frequencies are under study at MIT. The 17 GHz photocathode RF gun has a 1 1/2 cell ({pi} mode) room temperature cooper cavity. High power tests have been conducted at 5-10 MW levels with 100 ns pulses. A maximum surface electric field of 250 MV/m was achieved. This corresponds to an average on-axis gradient of 150 MeV/m. The gradient was also verified by a preliminary electron beam energy measurement. Even high gradients are expected in our next cavity design.

1995-12-31

368

Design considerations for the magnetic system of a prototype x-ray free electron laser  

Energy Technology Data Exchange (ETDEWEB)

A number of difficult technical challenges need to be solved in the fields of accelerator and free-electron laser (FEL) technologies in order to build an X-ray FEL. One of the tasks well suited to the Advanced Photon Source Low Energy Undulator Test Line (LEUTL) is to take the intermediate step of solving some of the problems of single-pass FEL operation in the ultraviolet range. The existing Advanced Photon Source (APS) linac, in addition to its role of supply positrons for the APS storage ring, will also be used to generate the particle beam for the LEUTL. Here, the design of the magnetic system for the high gain soft x-ray free electron laser is described.

1997-04-01

369

Design and installation of a low particulate, ultrahigh vacuum system for a high power free-electron laser  

International Nuclear Information System (INIS)

A high-average power (kW) infrared (IR) free-electron laser (FEL) is currently being commissioned for the Jefferson Laboratory FEL User Facility. The IR FEL is driven by a unique superconducting rf linac which is recirculated to recover electron beam power that is not radiated in the FEL. The design and installation of the vacuum system for the FEL involved particular attention to minimizing particulate contamination which could cause problems with the superconducting acceleration cavities and the high power FEL optics. Particulate contamination levels of all vacuum components were monitored during the cleaning process using laser scattering. Cleaning, transport, and installation procedures were developed to minimize the contamination of the complete system. We will summarize a data base we compiled of particulate contamination levels of the various components installed in the FEL vacuum system.

1999-03-01

370

Coherent spontaneous radiation from highly bunched electron beams  

International Nuclear Information System (INIS)

Coherent spontaneous radiation has now been observed in several FELs, and is a subject of great importance to the design of self-amplified spontaneous emission (SASE) devices. We report observations of coherent spontaneous radiation in both FIREFLY and the mid-infrared FEL at the Stanford Picosecond FEL Center. Coherent emission has been observed at wavelengths as short as 5 microns, and enhancement over incoherent levels by as much as a factor of 4x10"4 has been observed at longer wavelengths. The latter behavior was observed at 45 microns in FIREFLY with short bunches produced by off-peak acceleration and dispersive compression. We present temporal measurements of the highly bunched electron distributions responsible for the large enhancements, using both transition radiation and energy-phase techniques.

1995-08-21

371

Radiation-induced chemical modification of wood  

International Nuclear Information System (INIS)

The results of theoretical and experimental investigations, describing the effect of ionizing radiation on wood and its main components and methods for production of wood-plastic composites by means of radiation-induced chemical modification are generalized. Domestic and foreign experience in their production is systematized; physico-mechanical characteristics of new material, simulation and calculation of irradiating devices, as well as calculation and experimental study of #gamma#-radiation attenuation both by wood material and by wood of different species are given. Gamma sources ("6"0Co isotope, a hot loop of a nuclear reactor) as well as electron accelerators are considered as ionizing radiation sources.

1985-01-01

372

Improved SSAMS performance  

British Library Electronic Table of Contents (United Kingdom)

We operate a new NEC 250kV single-stage accelerator mass spectrometer (SSAMS) next to our established 5MV tandem. This permits good comparison of 14C-AMS and challenges SSAMS performance. Initial SSAMS ion-optical deficiencies have been addressed by shimming the injection magnet and 3permil 14C/13C measurement with background limited by sample chemistry is routine. Higher-precision analysis is also achievable. A problematic measurement interference remains, however. The small spectrometer was procured to add measurement capacity, and for experiments with positive ions, but is now the preferred instrument for both convenience and measurement quality.

2010-01-01

373

Getter pumping  

CERN Document Server

A surface may provide a useful pumping action when able to retain adsorbed gas molecules for the duration of a given experiment. To fulfil this condition at room temperature, strong binding forces, as those resulting from chemical reactions, are required. Materials able to react with gases to form stable chemical compounds are called getters. The two main families of getters (evaporable and non-evaporable, or NEG) are presented and discussed. Special emphasis is placed on the NEG strips currently used for the vacuum systems of particle accelerators, and on the newly developed NEG thin-film coatings, in view of their possible future applications.

2007-01-01

374

Unified interpretation for second-order subwavelength interference based on Feynman's path-integral theory  

International Nuclear Information System (INIS)

The second-order spatial subwavelength interference pattern is observed in a modified Michelson interferometer with single-mode continuous-wave laser beams. By analyzing our subwavelength interference experiment based on Feynman's path integral theory, a unified interpretation for all the second-order subwavelength interference is suggested.

2010-07-01

375

Free-electron lasers and related topics  

Energy Technology Data Exchange (ETDEWEB)

This past year has been very exciting for the experimental free-electron laser (FEL) programs. At three Laboratories, oscillator experiments were performed with wavelengths from the visible to far infrared. The output powers are steadily advancing. The status of these programs will be discussed. As shorter wavelengths and higher powers are pursued, higher currents with improved beam quality will be required. Advanced electron linacs should be developed to meet these demands. 13 references, 5 figures, 3 tables.

1984-01-01

376

Demonstration of neutron radiography and computed tomography at the University of Texas thermal neutron imaging facility  

Energy Technology Data Exchange (ETDEWEB)

A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed and built at the University of Texas TRIGA reactor. Herein the authors present preliminary results of radiography and tomography test experiments. These preliminary results showed that the beam is of high quality and is suitable for radiography and tomography applications. A more detailed description of the facility is given elsewhere.

1999-09-01

377

Demonstration of neutron radiography and computed tomography at the University of Texas thermal neutron imaging facility  

International Nuclear Information System (INIS)

A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed and built at the University of Texas TRIGA reactor. Herein the authors present preliminary results of radiography and tomography test experiments. These preliminary results showed that the beam is of high quality and is suitable for radiography and tomography applications. A more detailed description of the facility is given elsewhere

1999-06-06

378

Utilization of CTR to measure the evolution of electron-beam microbunching in a self-amplified spontaneous emission (SASE) free-electron laser (FEL)  

International Nuclear Information System (INIS)

We report on the first measurements of the z-dependent evolution of electron-beam microbunching as revealed through coherent transition radiation (CTR) measurements in a visible self-amplified spontaneous emission free-electron laser experiment. The increase in microbunching was detected by tracking the growth of the visible CTR signals as generated from insertable metal mirrors/foils after each of the last three undulators. The same optical imaging diagnostics that were used to track the z-dependent intensity of the undulator radiation (UR) were also used to track the electron beam/CTR information. Angular distribution, beam size, and intensity data were obtained after each of the last three undulators in the five-undulator series, and spectral information was obtained after the last undulator. The exponential growth rate of the CTR was found to be very similar to that of the UR and consistent with ...

2002-07-01

379

Utilization of CTR to measure the evolution of electron-beam microbunching in a self-amplified spontaneous emission (SASE) free-electron laser (FEL)  

International Nuclear Information System (INIS)

We report on the first measurements of the z-dependent evolution of electron-beam microbunching as revealed through coherent transition radiation (CTR) measurements in a visible self-amplified spontaneous emission free-electron laser experiment. The increase in microbunching was detected by tracking the growth of the visible CTR signals as generated from insertable metal mirrors/foils after each of the last three undulators. The same optical imaging diagnostics that were used to track the z-dependent intensity of the undulator radiation (UR) were also used to track the electron beam/CTR information. Angular distribution, beam size, and intensity data were obtained after each of the last three undulators in the five-undulator series, and spectral information was obtained after the last undulator. The exponential growth rate of the CTR was found to be very similar to that of the UR and consistent with ...

2001-12-21

380

Compressed-shell integrity measurements in spherical implosion experiments  

International Nuclear Information System (INIS)

The shell integrity near peak compression of spherical implosions using the 60-beam, 30-kJ UV OMEGA laser system [Opt. Commun. 133, 495 (1997)] has been measured. Hot core emission backlights a shell with a thin titanium-doped layer that is imaged at x-ray photon energies above and below the titanium K edge. The x-ray intensity ratio between the two images is related to perturbations in the cold, or absorbing, part of the shell. The measured cold-shell areal-density modulations, integrated over the time of peak compression, are of the order of 25% to 50% with nonuniformity spectra peaked at spatial wavelengths of 30 to 50 #mu#m and with the smallest detectable nonuniformity features extending down to spatial wavelengths of 12 to 15 #mu#m. Hot-shell areal-density modulations of the emitting part of the shell (inner edge) are of the order of 13% to 20%. The measured shell modulations are in agreement with the results of two-dimensional simulations that include ...

2001-06-01

381

Verification of electron beam therapy with storage phosphor images: Precision of field placement  

Energy Technology Data Exchange (ETDEWEB)

Portal verification images were generated from the photon contamination in electron beams produced by a linear accelerator during treatment of patients receiving high-energy electron radiation therapy (8-14 MeV). An experimental storage phosphor system was used to record the images and display them on laser-printed film. Images were obtained from four or more treatment fractions from 21 cases of head and neck cancer. Precision in field placement was estimated by determining the position of a selected anatomic landmark relative to the center of the field for each series of images. The average standard deviation in the field-position measurements was 3.8 mm. Several procedural problems were also detected and corrected after review of the verification images. The results indicate that the emphasis placed on monitoring and control of field-positioning error in high-energy electron treatments should be similar to the emphasis placed on this aspect ...

1990-04-01

382

Manufacture of wood/plastic composites by radiation  

International Nuclear Information System (INIS)

The manufacture and use of wood/plastic composite (WPC) as an example of wood matrix and wood sawdust/plastic composites (SDP) as an example of plastic matrix are reviewed. The raw material for WPC are mostly vinyl monomers, particularly methyl methacrylate and styrene. The reaction in WPC polymerization is radical polymerization. Researches on the radiation sources mostly resulted in gamma-ray. Electron beam can be applied only to thin products. The future use of WPC may be for furnitures, sporting goods, decorative parts and the like. Vital study on the reduction of manufacturing costs is required, for example, the improvement of reaction and the adoption of continuous process must be considered. The raw materials for SDP are wood sawdust, vinyl monomer (mostly methyl methacrylate) and resins. Electron beam accelerators are the most preferable radiation source because of its high efficiency and safe operation. SDP shows ...

1976-01-01

383

Electron beam processing of rubber wood fibers - polypropylene composites. Effects of reactive additives on the physical and mechanical properties  

International Nuclear Information System (INIS)

The purpose of this study is to determine the suitability of producing agro-fiber reinforced plastic composite (agro-FRPC) from rubber wood fiber blended in polypropylene matrix. The effects of varying fiber dimension and fiber content on the physical and mechanical properties of the composite were evaluated to provide an insight into the fiber matrix adhesion. The effects of reactive additives on the physical and mechanical properties of the composite were evaluated which provides the insight on the reinforcement of the composite. Rubber wood fiber used in this study is currently being used in the manufacturing of medium density fiber (MDF) board. Two sizes of rubber wood fiber were used i.e. 0.5-1.0 mm and 1.0-2.0 mm. Homopolymer polypropylene of MFI 14.0 was used as a matrix. The irradiation work was carried out using electron beam accelerator, 3.0 MeV, 3.0 mA. Various types of reactive additives (RA) with mono-functional, di-functional, ...

2000-03-13

384

Effect of Al and Be ions pre-implantation on formation and growth of helium bubbles in SiC/SiC composites  

Energy Technology Data Exchange (ETDEWEB)

The effect of Al and Be ions pre-implantation on microstructural change and, the formation and growth of He bubbles in SiC/SiC composite was investigated. Four kinds of ion implanted specimens were prepared with 100 appm Al, 1000 appm Al, 100 appm Be and 1000 appm Be implanted. No microstructural change was observed in the matrices and fibers of SiC/SiC composites implanted with Al or Be ions up to 1000 appm. The un-implanted and Al or Be pre-implanted SiC/SiC composites were simultaneously irradiated to 10 dpa using triple ion-beams (6.0-MeV Si{sup 2+}, 1.0-MeV He{sup +} and 340-keV H{sup +}) at 1000 deg. C. Helium bubbles were formed in every matrix and fiber irradiated by triple ion-beams. The size of He bubbles in the matrix was increased by implanting Al or Be ions and increased with increasing amount of implanted Al or Be ions. The size of He bubbles in the fiber was slightly increased by implanting Al or Be ions. These results suggest ...

2007-03-15

385

Effect of Al and Be ions pre-implantation on formation and growth of helium bubbles in SiC/SiC composites  

International Nuclear Information System (INIS)

The effect of Al and Be ions pre-implantation on microstructural change and, the formation and growth of He bubbles in SiC/SiC composite was investigated. Four kinds of ion implanted specimens were prepared with 100 appm Al, 1000 appm Al, 100 appm Be and 1000 appm Be implanted. No microstructural change was observed in the matrices and fibers of SiC/SiC composites implanted with Al or Be ions up to 1000 appm. The un-implanted and Al or Be pre-implanted SiC/SiC composites were simultaneously irradiated to 10 dpa using triple ion-beams (6.0-MeV Si"2"+, 1.0-MeV He"+ and 340-keV H"+) at 1000 deg. C. Helium bubbles were formed in every matrix and fiber irradiated by triple ion-beams. The size of He bubbles in the matrix was increased by implanting Al or Be ions and increased with increasing amount of implanted Al or Be ions. The size of He bubbles in the fiber was slightly increased by implanting Al or Be ions. These results suggest that Al or Be as ...

2007-03-01

386

A conceptual design study of superconducting proton linac for Neutron Science Project. 1  

Energy Technology Data Exchange (ETDEWEB)

The Neutron Science Project at Japan Atomic Energy Research Institute has been proposed for the research of nuclear transmutation technology and the basic science with a spallation neutron source. The project calls for an 8MW proton linac which accelerates 5.3mA average current cw and pulsed beams up to 1.5GeV. The superconducting (SC) rf-cavity is the main option for the energy part from 100MeV to 1.5GeV because by using the SC structure, less power is consumed in cw operation than by using a normal conducting (NC) structure. A conceptual design study of the superconducting proton linac is reported. The SC linac is composed of 8 {beta} sections. Each section has the identical 5-cell cavities with the surface peak field of 16MV/m. The total number of cavities is 284, and the length of the SC linac is 690m. The lattice design is determined with the equipartitioned condition and the matched envelope equations for the minimum emittance growth. The ...

1998-09-01

387

Determination of distal dose edge location by measuring right-angled prompt-gamma rays from a 38 MeV proton beam  

International Nuclear Information System (INIS)

In clinical applications, it is very important to accurately determine the range of a proton beam in a patient. Recently, a prototype prompt-gamma scanning system, called a prompt-gamma scanner (PGS), has been constructed at Hanyang University in Korea with the collaboration of the Korean national cancer center (NCC), based on a series of Monte Carlo simulations. The PGS system is composed of a prompt-gamma collimator, a CsI(Tl) scintillation detector, a multi-channel analyzer (MCA), a precision movement system, and an integrated readout system. The prompt-gamma collimator is designed to effectively shield high-energy neutrons from the proton beam passage and subsequent capture gammas. The PGS system can be used to scan the distribution of the prompt gammas in the patient from the proton beam passage. The distribution of the prompt gammas can then be used to determine the proton beam range or the distal ...

2007-09-21

388

Beam-beam compensation activities at Fermilab. R and D status  

International Nuclear Information System (INIS)

The beam-beam interaction in the Tevatron produce the betatron tune spread in each bunch and a bunch-to-bunch tune spread. The tune spread sets limits on bunch intensity and luminosity. The beam-beam effects for antiprotons are usually more severe since the proton bunch population is higher. The beam-beam effects for antiprotons can in principle be compensated with the use of an electron beam with a corresponding charge density. The status of studies of possibilities of the beam-beam compensation is reviewed in this paper.

1999-06-09

389

The international management of big scientific research programs. The example of particle physics; La gestion internationale des grands programmes de recherche scientifique l'exemple de la physique des particules  

Energy Technology Data Exchange (ETDEWEB)

High energy physics is a basic research domain with a well established European and international cooperation. Cooperation can be of different type depending on the size of the facilities involved (accelerators), on their financing, and on the type of experiments that use these facilities. The CERN, the European center for nuclear research, created in October 1954, is the best example of such a cooperation. This article examines first the juridical and scientifical structure of the CERN and the mode of organization of big experiments. Then, it presents the role of international committees in the establishment of a common scientific policy in Europe and in the rest of the world. Finally, the possible future evolution of the CERN towards a worldwide project is evoked. (J.S.)

2004-07-01

390

Strong fields and recycled accelerator parts as a laboratory for fundamental physics  

International Nuclear Information System (INIS)

Over the last few years it has become increasingly clear that low energy, but high precision experiments provide a powerful and complementary window to physics beyond the Standard Model. In this note we illuminate this by using minicharged particles as an example. We argue that minicharged particles arise naturally in extensions of the Standard Model. Compatibility with charge quantization arguments suggests that minicharged particles typically arise together with a massless hidden sector U(1) gauge field. We present several low energy experiments employing strong lasers, electric and magnetic fields that can be used to search for (light) minicharged particles and their accompanying U(1) gauge boson.

2009-12-01

391

Brane-world Quantum Gravity  

CERN Document Server

The Arnowitt-Deser-Misner canonical formulation of general relativity is extended to the covariant brane-world theory in arbitrary dimensions. The exclusive probing of the extra dimensions makes a substantial difference, allowing for the construction of a non-constrained canonical theory. The quantum states of the brane-world geometry are defined by the Tomonaga-Schwinger equation, whose integrability conditions are determined by the classical perturbations of submanifolds contained in the Nash's differentiable embedding theorem. In principle, quantum brane-world theory can be tested by current experiments in astrophysics and by near future laboratory experiments at Tev energy. The implications to the black-hole information loss problem, to the accelerating cosmology, and to a quantum mathematical theory of four-sub manifolds are briefly commented.

2007-01-01

392

Determination of two-phase natural circulation interfacial parameters by real-time neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Experimental investigations have been conducted to determine two-phase natural circulation interfacial parameters by real-time neutron radiography. The natural circulation loop used in the present experiments consists of a vertical two-phase section, a gas liquid separator, and a gas injection/heating section. Experiments were performed in a neutron beam for visualization using realtime neutron radiography system. The natural circulation was initiated by injection of known gas flow rate in the heated section. Two-phase flow interfacial parameters including interfacial geometry and phase velocities etc. for bubbly flow and slug flow patterns observed in the experiments will be given in detail. The results indicate that while the natural circulation is largely as expected and that steady stable flows are possible, there are some local phenomena that introduce instabilities due to the interfacial phenomena ...

2003-07-01

393

Determination of two-phase natural circulation interfacial parameters by real-time neutron radiography  

International Nuclear Information System (INIS)

Experimental investigations have been conducted to determine two-phase natural circulation interfacial parameters by real-time neutron radiography. The natural circulation loop used in the present experiments consists of a vertical two-phase section, a gas liquid separator, and a gas injection/heating section. Experiments were performed in a neutron beam for visualization using realtime neutron radiography system. The natural circulation was initiated by injection of known gas flow rate in the heated section. Two-phase flow interfacial parameters including interfacial geometry and phase velocities etc. for bubbly flow and slug flow patterns observed in the experiments will be given in detail. The results indicate that while the natural circulation is largely as expected and that steady stable flows are possible, there are some local phenomena that introduce instabilities due to the interfacial phenomena ...

2003-10-05

394

Simultaneous production of "2"8Mg and "4"7Ca by high-energy heavy-ion irradiation for applications in biology  

International Nuclear Information System (INIS)

With the aim of preparing carrier-free "2"8Mg and "4"7Ca simultaneously, Ti, V and Fe targets were examined by irradiating with high-energy ions of "1"2C, "1"4N and "1"6O accelerated by the RIKEN ring cyclotron. Among the targets, V gave the highest cross section for the formation of both "2"8Mg and "4"7Ca irrespective of the kind of beams. The cross section for the formation of "2"8Mg by the reactions of Ti, V and Fe targets with ion beams increased in the order of "1"2C<"1"6O<"1"4N. On the other hand, the three beams exhibited almost the same cross sections for the formation of "4"7Ca by the reaction of a given target. Titanium and V were selected as prospective targets and "1"4N as a suitable beam for the production of "2"8Mg and "4"7Ca. Chemical separation procedures of the radiotracers in carrier- and salt-free states have been established by using cation exchange resins. ...

395

Silund Nanosecond High-Current Linear Induction Accelerator ...  

Science.gov (United States)

... the high current induction linear accelerator of the nanosecond range, meant to be used as injector in the collective ion accelerator, are presented. ...

1972-07-13

396

The DITE tokamak experiment  

Science.gov (United States)

The DITE (Divertor Injection Tokamak Experiment) program has been undertaken to demonstrate the feasibility of impurity control by the use of a diverter in an injection-heated toroidal plasma configuration. Rather than behaving in accordance with neoclassical toroidal containment theory, the plasma is subject to various instabilities, particularly the resistive fluid MHD types, follows the empirical scaling of energy confinement time with plasma parameters observed in other plasma devices. DITE experiments have, however, extended the range of current and density. Impurities arising from plasma interactions with the vacuum vessel surface are controlled by the bundle divertor, which diverts a portion of plasma and power in the plasma scrape-off layer into a separate target chamber where impurities can be removed. Auxiliary plasma heating is provided by the injection of powerful beams of neutral hydrogen atoms produced by ...

1981-04-01

397

Heavy ion induced changes in nuclear waste glasses: a micro Raman investigation  

International Nuclear Information System (INIS)

Borosilicate based glass formulations have been found suitable for fixing the HLW (high level radioactive liquid waste) generated after reprocessing of the spent nuclear fuel. As the glass experiences continuous irradiation by #alpha#, #beta#a, and #gamma# radiations from the radioactive components of HLW, alteration in the glass structure may occur. Understanding of these structural evolutions of the nuclear waste glasses under irradiation is crucial to secure long term disposal and predict their behavior. In the present work, alkali based barium borosilicate glasses, having composition similar to that of Trombay Research Reactor waste glass were irradiated with high energy "1"2C beam and the radiation induced changes were monitored by micro Raman experiment. Since a "1"2C atom can be considered as a cluster of alphas, this beam was chosen to yield linear energy losses (LET) comparable to that in case ...

2010-12-01

398

Monte Carlo simulation of electron cones used in electron beam therapy  

International Nuclear Information System (INIS)

A Siemens Mevatron KV2 accelerator installed at the Royal Adelaide Hospital employs cylindrical solid-walled electron cones for some electron collimation. The cones being used at present result in treatment fields that do not always conform with the International Electrotechnical Commission (IEC) Standards (particularly at high energies). The aim of this project was to simulate the existing cones using Monte Carlo methods in order to evaluate potential cone modifications required to overcome the field irregularities. Simulations were performed using the EGS4 (Electron Gamma Shower version 4, distribution II) Monte Carlo code installed on a DEC Alpha workstation at the University of South Australia. To rigorously simulate the existing electron cones it was necessary to also simulate various components within the treatment head of the linear accelerator. Results of simulations for existing cones were found to be consistent with experimental data. ...

1998-09-01

399

Nuclear multifragmentation experiment at the KEK 12 GeV PS. The first results of the KEK-PS E337 experiment  

Energy Technology Data Exchange (ETDEWEB)

A KEK-PS experiment E337 `Angular correlation of intermediate mass fragments emitted from the target multifragmentation reactions with 12 GeV protons` is an extension of the E288 performed a few years ago. The E288 revealed that the proton-induced target multifragmentation reactions at 12 GeV showed quite interesting phenomena such as 70 degree peaking angular distributions for intermediate mass fragments. In December, 1955, the test experiment with 12 GeV protons was started at KEK using this newly constructed counter array of 37 Bragg Curve Counters. The main production experiment was performed in April and May in 1996 after debugging the new counter system and DAQ system, as well as EP1-B beam line. Data with Au, Tm, Sm and Ag targets were successfully accumulated. The data are in the analysis stage, and several interesting features of high energy nuclear reactions have already been seen. (G.K.)

1997-05-01

400

VLF wave stimulation by pulsed electron beams injected from the space shuttle  

International Nuclear Information System (INIS)

Among the investigations conducted on the space shuttle flight STS 3 March 1982 was an experiment in which a 1-keV, 100-mA electron gun was pulsed at 3.25 and 4.87 kHz. The resultant waves were measured with a broadband plasma wave receiver. At the time of flight the experimental setup was unique in that the electron beam was square wave modulated and that the shuttle offered relatively long times for in situ measurements of the ionospheric plasma response to the VLF pulsing sequences. In addition to electromagnetic response at the pulsing frequencies the waves exhibited various spectral harmonics as well as the unexpected occurrence of satellite lines around those harmonics. Both phenomena occurred with a variety of different characteristics for different pulsing sequences.

401

The BCNT treatment planning for the Brookhaven trials on human gliomas  

International Nuclear Information System (INIS)

Boron neutron capture therapy (BNCT) trials for human glioma (glioblastoma multiform) were initiated September 1994 at the Brookhaven National Laboratory (BNL). Patients are given p-boronophenylalanine-fructose (BPA-F) intravenously as the boron carrier followed by exposure to the epithermal-neutron beam at the Brookhaven Medical Research Reactor (BMRR). The initial phase of the study is to determine safety and toxicity of the drug and irradiation procedure. The epithermal-neutron beam was developed in a joint effort by BNL and Idaho National Engineering Laboratory (INEL) researchers. For the human trials, treatment planning and radiation dose estimation is performed using the BNCT-Rtpe and the rtt-MC computer codes developed by the INEL BNCT program. This paper discusses our initial experience using these treatment planning codes for human subjects. The basic principles of BNCT have been previously documented.

402

Surface analysis by Fourier-transform infrared (FTIR) spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

A diffuse-reflectance capability for the Fourier transform infrared spectrometer at the Y-12 Plant Laboratory has been implemented. A sample cell with a 25 to 400/sup 0/C temperature-controlled sample stage and an ultrahigh-vacuum-to-atmospheric pressure gas-handling capability has been developed. Absorbance of light from the spectrometer beam, resulting from the beam being scattered from a powder sample, can be measured. This capability of detecting molecular species on and in powders is to be used to study chemisorption on actinide and rare-earth metals, alloys, and compounds. Cell design is described along with experiments demonstrating its performance in detecting moisture absorption on uranium oxide, moisture and carbon dioxide absorption on the lithium hydride/hydroxide system, and carbon dioxide absorption on potassium borohydride. 13 figures.

1981-08-12

403

Radiochemical investigations of nuclear properties. Progress report, October 1, 1976--September 30, 1977  

International Nuclear Information System (INIS)

Progress in experimental investigations of high spin excitations in spherical and transitional nuclei in the A = 180 to 204 mass range is described. Most of the experiments were performed by in-beam #gamma#-ray spectroscopy using beams of "3He, "4He, and "1"2C ions from the Michigan State University cyclotron. The main results of studies of the nuclei "1"9"5 "1"9"7 "1"9"9 "2"0"1 "2"0"2 "2"0"3Pb, "1"9"6 "1"9"7 "1"9"9 "2"0"0Hg and "1"8"6 "1"8"7 "1"8"8 "1"8"9Pt are summarized.

404

Measurement of electron-impact single-ionization cross sections of Ar"8"+  

International Nuclear Information System (INIS)

A crossed-electron-ion-beam experiment was used to measure the total ionization cross section for Ar"8"+ in the energy range from 50 to 600 eV. The present results are roughly in agreement with the previous measurements of Defrance et al. [Nucl. Instrum. Methods Phys. Res. B 23, 256 (1987)] above 450 eV. However, the present measurements show a significant contribution below the threshold for direct ionization. The present measurements agree with the distorted-wave calculations of Pindzola et al. [Phys. Rev. A 41, 1375 (1990)] when 3% of the incident ion beam is assumed to be in metastable states and excitation autoionization from metastable states is included.

405

Fast Wire Scanner Calibration  

CERN Document Server

The fast rotating wire scanners installed in the PS and the PS booster are used for the precise transversal profile measurements in horizontal and vertical planes. The scanners may show large position measurement errors if no special treatment is applied to the acquired data. The aim of the calibration is to obtain a correction algorithm for the systematic position measurement error due to mechanical and electronic offsets. A new calibration system has been developed and introduced at CERN for the scanners implementing position feedback control. The calibration method is based on a substitution of a particle beam by a laser one where the laser beam position is well known. According to the previous experience the following crucial requirements to the system have been taking into consideration: heavy and mechanically stable design of the calibration bench to reduce mechanical oscillations of scanner parts; automation of the ...

2009-01-01

406

Annihilation of antiprotons in light nuclei  

CERN Document Server

CR-39 detectors have been exposed to a 5.9-MeV antiproton beam using the low energy antiproton ring (LEAR) facility at CERN. At this energy, tracks of antiprotons appear in a CR-39 detector after 135 min of etching in 6 M NaOH at 70C. Fluence of the antiproton beam has been determined using track density. We have also found tracks in the etched CR-39 detector at different depths (250-500 mum). These tracks have resulted from the annihilation of antiprotons with the constituents (H, C and O) of the CR-39 detector. The goal of the experiment is to develop a simple and low-cost method to study properties of antiparticles and those formed after annihilation of these particles with the target matter.

2006-01-01

407

Radiation-hardening of magnet coils  

International Nuclear Information System (INIS)

The first essential before embarking on the radiation-hardening of electrical insulation - mostly magnet coils - in any beam line application is to obtain a reliable estimate of the dose to the components. These are examples ( switchyards at SLAC and LAMPF) where the degree of hardness specified was much higher than was required. Although experience shows that the cost premium for substantial radiation - hardening is of the order of 10%, it has also become clear that well - designed beam line have negligible losses: hardening is required only in the vicinity of targets, collimators or other beam - intercepting devices. Where the beam is deliberately scraped, local shielding will minimize the associated radiation in the surroundings. Electron machines have their own special problems due to synchrotron radiation, so certainly coils and other electrical equipment should be kept away ...

1989-03-01

408

Molecular-beam/surface-science apparatus for state-resolved chemisorption studies using pulsed-laser preparation  

International Nuclear Information System (INIS)

We describe a new apparatus that combines pulsed laser excitation in a molecular beam with surface-science methods for preparation of clean single-crystal surfaces and detection of adsorbates to enable state-selected studies of gas-surface reaction dynamics. Reactant molecules are prepared in specific vibrationally excited states via overtone pumping using tunable, narrow-band laser radiation. The collision-free environment of the molecular beam prevents relaxation of the prepared molecules before impact on the target surface and enables complete control over the collision energy and incidence angle. Chemisorption products are detected after a given deposition time by Auger electron spectroscopy. To achieve sufficient beam flux of state-selected reactant molecules for product detection by standard surface-science techniques, we use a high-intensity, short-pulse molecular-beam source matched to the low ...

2003-09-01

409

FABRICATION OF BISMUTH NANOWIRE DEVICES USING FOCUSED ION BEAM MILLING  

International Nuclear Information System (INIS)

In this work, a focused ion beam (FIB) milling process has been developed to fabricate 50 nm Bi nanowire and transistor structures using FEI-200 dual beam FIB system. For the fabrication, 50 nm bismuth film was thermally evaporated through EBL patterned PMMA windows onto SiO_2 substrates with pre-defined contact pads. Bi nanowire widths ranging from 30 nm to 100 nm have been successfully fabricated by milling out unwanted areas using 30 KeV Ga+ ion beam. A single-pixel-line ion beam blanking technique has been utilised to fabricate Bi nanowire as small as 30 nm in diameter and few micrometers long. In order to form good ohmic contacts for sub 50 nm bismuth nanowires, a drill-and-fill process has been developed using FIB to sputter away the surface oxide of bismuth after the in-situ platinum nanowire contacts deposition. To our knowledge, this is the first time a focused ion beam ...

2009-07-23

412

The Next Linear Collider: NLC2001  

Energy Technology Data Exchange (ETDEWEB)

Recent studies in elementary particle physics have made the need for an e{sup +}e{sup -} linear collider able to reach energies of 500 GeV and above with high luminosity more compelling than ever [1]. Observations and measurements completed in the last five years at the SLC (SLAC), LEP (CERN), and the Tevatron (FNAL) can be explained only by the existence of at least one particle or interaction that has not yet been directly observed in experiment. The Higgs boson of the Standard Model could be that particle. The data point strongly to a mass for the Higgs boson that is just beyond the reach of existing colliders. This brings great urgency and excitement to the potential for discovery at the upgraded Tevatron early in this decade, and almost assures that later experiments at the LHC will find new physics. But the next generation of experiments to be mounted by the world-wide particle physics community must not only find ...

2002-01-14

413

Studies of accelerated compact toruses  

Energy Technology Data Exchange (ETDEWEB)

In an earlier publication we considered acceleration of plasma rings (Compact Torus). Several possible accelerator configurations were suggested and the possibility of focusing the accelerated rings was discussed. In this paper we consider one scheme, acceleration of a ring between coaxial electrodes by a B/sub theta/ field as in a coaxial rail-gun. If the electrodes are conical, a ring accelerated towards the apex of the cone undergoes self-similar compression (focusing) during acceleration. Because the allowable acceleration force, F/sub a/ = kappaU/sub m//R where (kappa < 1), increases as R/sup -2/, the accelerating distance for conical electrodes is considerably shortened over that required for coaxial electrodes. In either case, however, since the accelerating flux can expand as the ring ...

1983-01-04

414

Dosimetry limitations and a dose correction methodology for step-and-shoot IMRT  

Energy Technology Data Exchange (ETDEWEB)

For the step-and-shoot intensity-modulated radiation therapy (IMRT) technique, the combination of high dose rate, multiple beam segments and low dose per segment can lead to significant differences between the planned dose and the dose delivered to the patient. In this technique, a dose delivery inaccuracy known as the 'overshoot' effect is caused by the dose servo control system. This typically occurs in the first and last beam segments and causes an over- and underdose, respectively. Some dose positional error in the segment sequence is also possible there. Commercial ionization chambers (RK-type) and radiographic Kodak films were used for the measurements. The reported results were obtained using the Pinnacle{sup 3}-V6.2 treatment planning system and a Varian Clinac 21 EX linear accelerator equipped with a 120-leaf Millennium MLC. The dose inaccuracy measurements were based on the comparison of the dose ...

2006-02-07

415

Implementation of an algorithm for absorbed dose calculation in high energy photon beams at off axis points  

International Nuclear Information System (INIS)

Full text: A semiempirical algorithm for absorbed dose calculation at off-axis points in irregular beams was implemented. It is well known that semiempirical methods are very useful because of their easy implementation and its helpfulness in dose calculation in the clinic. These methods can be used as independent tools for dosimetric calculation in many applications of quality assurance. However, the applicability of such methods has some limitations, even in homogeneous media, specially at off axis points, near beam fringes or outside the beam. Only methods derived from tissue-air-ratio (TAR) or scatter-maximum-ratio (SMR) have been devised for those situations, many years ago. Despite there have been improvements for these manual methods, like the Sc-Sp ones, no attempt has been made to extend their usage at off axis points. In this work, a semiempirical formalism was introduced, based on the works of Venselaar et al. ...

2008-10-19

416

Track clustering and vertexing algorithm for L1 trigger  

Energy Technology Data Exchange (ETDEWEB)

One of the keystones of the canceled BTeV experiment (proposed at Fermilab's Tevatron) was its sophisticated three-level trigger. The trigger was designed to reject 99.9% of light-quark background events and retain a large number of B decays. The BTeV Pixel Detector provided a 3-dimensional, high resolution tracking system to detect B signatures. The Level 1 pixel detector trigger was proposed as a two stage process, a track-segment finder and a vertex finder which analyzed every accelerator crossing. In simulations the track-segment finder stage outputs an average of 200 track-segments per accelerator crossing (2.5MHz). The vertexing stage finds vertices and associates track-segments with the vertices found. This paper proposes a novel adaptive pattern recognition model to find the number and the estimated location of vertices, and to cluster track-segments around those vertices. The track clustering and vertex ...

2005-10-01

417

Extreme Environments of Next-Generation Energy Systems and Materials: Can They Peacefully Co-Exist? (452nd Brookhaven Lecture)  

Energy Technology Data Exchange (ETDEWEB)

"What happens to conventional metals near the ocean?" you might ask the workers who are repairing the water tower at Jones Beach. They will tell you that both the tower's steel framework and copper roof show extensive corrosion from the salty air. To power future generations of cars, homes, utility plants, and even particle accelerators, unprecedented levels of efficiency will be needed. Such efficiency will require new unconventional alloys and composite materials that can also withstand high temperatures, intense radiation fluxes, high stresses, and other extreme conditions in highly corrosive environments that accelerate the aging and weakening of materials, as salty air weakens steel and copper. During the lecture, Simos will discuss the demands of next-generation energy systems and focus on the extreme conditions that materials used in these systems will perform under. He will also explain Brookhaven Lab's role in past, ...

2009-06-17

418

Dose planning and dose delivery in radiation therapy  

International Nuclear Information System (INIS)

A method has been developed for calibration of CT-numbers to volumetric electron density distributions using tissue substitutes of known elemental composition and experimentally determined electron density. This information have been used in a dose calculation method based on photon and electron interaction processes. The method utilizes a convolution integral between the photon fluence matrix and dose distribution kernels. Inhomogeneous media are accounted for using the theorems of Fano and O'Connor for scaling dose distribution kernels in proportion to electron density. For clinical application of a calculated dose plan, a method for prediction of accelerator output have been developed. The methods gives the number of monitor units that has to be given to obtain a certain absorbed dose to a point inside an irregular, inhomogeneous object. The method for verification of dose distributions outlined in this study makes it possible to exclude the treatment related ...

2008-08-01

419

Long-term effects of prenatal x-ray of human females: reproductive experience  

Energy Technology Data Exchange (ETDEWEB)

A cohort of singleton black human females exposed to diagnostic x-ray in utero and controls matched by parity, hospital of birth and birthdate have been followed to ages 25 to 30 years in Baltimore, Maryland. The search for possible effects of prenatal irradiation has focused on health, growth, development, and reproductive experience of exposed and control women. This paper reports findings related to reproductive experience. From an original data set of 1458 matched exposed-control pairs of women, questionnaire responses were received from 1109 exposed and 1124 control women including 852 each from pairs in which both the exposed and control woman responded. After careful search for alternative explanations of the findings, the authors concluded that females exposed in utero to low doses of x-ray (probably 1 to 5 rads) had significant increases in their rates of early onset of menses, births at age 15 years or less, numbers of living ...

1981-09-01

420

Surface physics with cold and thermal neutron reflectometry. Progress report, April 1, 1991--March 31, 1992  

Energy Technology Data Exchange (ETDEWEB)

Three aspects of the research project ``Surface physics with cold and ultracold neutron reflectometry`` were stressed during the present first year: (1) Setup of the reflectometer facility at the research reactor of the Rhode Island Nuclear Science Center. The installation provides a narrow ``pencil beam`` analyzed by time of flight using a chopper system. Following beam characterization and a test measurement of the total cross section of copper single crystal first reflectivity measurements are currently performed using a supermirror. (2) Design stud for the ultracold neutron imaging system, with involvement of the relevant industry. Bids are available for several components indicating that it will be very difficult to build the entire system unless further funds become available. (3) Analysis of features of neutron reflection from surfaces with special emphasis on the effect of surface roughness both on the specular beam ...

1991-11-01

421

Surface physics with cold and thermal neutron reflectometry  

Energy Technology Data Exchange (ETDEWEB)

Three aspects of the research project Surface physics with cold and ultracold neutron reflectometry'' were stressed during the present first year: (1) Setup of the reflectometer facility at the research reactor of the Rhode Island Nuclear Science Center. The installation provides a narrow pencil beam'' analyzed by time of flight using a chopper system. Following beam characterization and a test measurement of the total cross section of copper single crystal first reflectivity measurements are currently performed using a supermirror. (2) Design stud for the ultracold neutron imaging system, with involvement of the relevant industry. Bids are available for several components indicating that it will be very difficult to build the entire system unless further funds become available. (3) Analysis of features of neutron reflection from surfaces with special emphasis on the effect of surface roughness both on the ...

1991-11-01

422

Plasma dynamics in the PF-1000 device under full-scale energy storage: II. Fast electron and ion characteristics versus neutron emission parameters and gun optimization perspectives  

International Nuclear Information System (INIS)

Electron and ion beam dynamics of the PF-1000 facility were investigated for the first time at its upper energy limit (?1 MJ) in relation to neutron emission, the pinch's plasma ('target') characteristics and some other parameters with the help of a number of diagnostics with ns temporal resolution. Special attention was paid to the temporal and the spatial cross correlations of different phenomena. Results of these experiments are in favour of a neutron emission model based on ion beam-plasma interaction with three important features: (1) the plasma target is hot and confined during a few 'inertial confinement times'; (2) the ions of the main part of the beam are magnetized and entrapped around the pinch plasma target for a period longer than the characteristic time of the plasma inductive storage system and (3) ion-ion collisions (both fusion collisions, due to head-on impacts and Coulomb collisions) ...

2007-06-21

423

Observation of multiorder coherent Raman sidebands in solid hydrogen film  

Energy Technology Data Exchange (ETDEWEB)

We investigated the Raman coherence characteristics of a solid hydrogen film deposited on a sapphire substrate held at 5.3 K. Using Raman coherence prepared with two single-frequency pulsed lasers, we generated the multiorder coherent Raman sidebands in solid hydrogen film. The highorder Raman sidebands were obtained under strong pumping intensities (>= 230 MW/cm{sup 2}). The generated anti-Stokes(AS)-Raman sidebands extend from the ultraviolet (292 nm for the AS5 band) to the visible (565 nm for the AS1 band) region. The multiorder Raman sideband generation is found to be due to the parametric coupling of pump and coupling lasers. The frequency conversion efficiency from pumping beams to the first AS-Raman sideband shows a maximum (14 %) at a pumping intensity of 360 MW/cm{sup 2}. From an experiment that makes the multimode probe beam beat with the prepared Raman coherence, we found that the prepared Raman coherence ...

2004-07-15

424

Observation of multiorder coherent Raman sidebands in solid hydrogen film  

International Nuclear Information System (INIS)

We investigated the Raman coherence characteristics of a solid hydrogen film deposited on a sapphire substrate held at 5.3 K. Using Raman coherence prepared with two single-frequency pulsed lasers, we generated the multiorder coherent Raman sidebands in solid hydrogen film. The highorder Raman sidebands were obtained under strong pumping intensities (? 230 MW/cm2). The generated anti-Stokes(AS)-Raman sidebands extend from the ultraviolet (292 nm for the AS5 band) to the visible (565 nm for the AS1 band) region. The multiorder Raman sideband generation is found to be due to the parametric coupling of pump and coupling lasers. The frequency conversion efficiency from pumping beams to the first AS-Raman sideband shows a maximum (14 %) at a pumping intensity of 360 MW/cm2. From an experiment that makes the multimode probe beam beat with the prepared Raman coherence, we found that the prepared Raman coherence replicates the ...

2004-07-01

425

Measurement of the Electron Affinities of Indium and Thallium  

Energy Technology Data Exchange (ETDEWEB)

The electron affinities of indium and thallium were measured in separate experiments using the laser-photodetachment electron spectroscopy technique. The measurements were performed at the University of Nevada, Reno. Negative ion beams of both indium and thallium were extracted from a cesium-sputter negative ion source, and mass analyzed using a 90{sup o} bending magnet. The negative ion beam of interest was then crossed at 90{sup o} with a photon beam from a cw 25-Watt Ar{sup +} laser. The resulting photoelectrons were energy analyzed with a 160{sup o} spherical-sector spectrometer. The electron affinity of In({sup 2}P{sub 1/2}) was determined to be 0.404 {+-} 0.009 eV and the electron affinity of thallium was determined to be 0.377 {+-} 0.013 eV. The fine-structure splittings in the ground states of the negative ions were also determined. The experimental measurements will be compared to several ...

1999-03-20

426

In-situ and post-irradiation fatigue properties of the ferritic-martensitic steel Manet at T=250 C  

Energy Technology Data Exchange (ETDEWEB)

Strain controlled fatigue experiments on the modified ferritic-martensitic 12% Cr-steel Manet have been performed during, after and without irradiation. Continuous push-pull cycling of the hollow fatigue specimens with a cycle ratio R=-1, an axial strain rate of 8.10{sup -4} s{sup -1} and total strain ranges {Delta}{epsilon}{sub t} between 0.42% and 1.0% has been applied in vacuum (5.10{sup -3} Pa) at T=250 C. For the irradiation, a 104 MeV {alpha}-particle beam was used. Compared to unirradiated specimens, in-beam specimens undergo irradiation hardening at an advanced fatigue/implantation stage. Post-irradiation specimens show significantly higher total stress amplitudes and reduced fatigue lives. TEM investigations of in-beam and post-irradiation specimens reveal helium bubbles with different diameters on internal surfaces and in the matrix. (orig.).

1996-10-01

429

Total skin electron beam therapy for cutaneous lymphomas and leukemias  

International Nuclear Information System (INIS)

Total skin electron beam therapy (TSEB) was used in the treatment of 33 patients with lymphoma and 13 patients with leukemia involving extensive segments of the skin surface. Twenty-two of 23 had lesions as a primary manifestation of lymphoma (primary cutaneous lymphoma-PCL) and 11 developed cutaneous lesions following disseminated nodal lymphoma (secondary cutaneous lymphoma-SCL). A once weekly fractionation scheme was employed to irradiate the entire skin surface with 3.5 to 4 MeV electron beam from a 6 MeV linear accelerator. During each weekly session, 400 rad were delivered to the entire skin and a complete course consisted of 4-6 consecutive weekly sessions. The majority of patients have been previously treated elsewhere for various periods and all patients have been at risk for a median of 12 months, range from 12-117 months following TSEB. Striking predominance of the diffuse pattern (76%) was demonstrated in both ...

430

Studies of nuclear processes at the Triangle Universities Nuclear Laboratory. Progress report, 1 September 1995--31 August 1996  

Energy Technology Data Exchange (ETDEWEB)

The Triangle Universities Nuclear Laboratory (TUNL)--a collaboration of Duke University, North Carolina State University, and the University of North Carolina at Chapel Hill--has had a very productive year. This report covers parts of the second and third year of a three-year grant between the US Department of Energy and the three collaborating universities. The TUNL research program focuses on the following areas: precision test of parity-invariance violation in resonance neutron scattering at LANSCE/LANL; parity violation measurements using charged-particle resonances in A = 20--40 targets and the A = 4 system at TUNL; chaotic behavior in the nuclei {sup 30}P and {sup 34}Cl from studies of eigenvalue fluctuations in nuclear level schemes; search for anomalies in the level density (pairing phase transition) in 1f-2p shell nuclei using GEANIE at LANSCE/LANL; parity-conserving time-reversal noninvariance tests using {sup 166}Ho resonances at Geel, ORELA, or LANSCE/LANL; nuclear ...

1996-09-01

431

Radial dose distribution of 6.0 MeV/n #alpha#-particle in water  

International Nuclear Information System (INIS)

For the study of radiation biology and its application to radiotherapy, the double differential cross section of electron emission from water vapor induced by 6.0 MeV alpha particle beam is measured. The energy spectra of electrons ranging 7- 10000 eV are detected by the electrostatic analyzer and micro channel plate. The measurements are made at angles between 20 and 160 degrees. With use of this data set, the radial dose distribution in water is calculated by using KURBUC code. It is the Monte Carlo type code of the electron transport process, where the track of the electron is simulated through each individual interactions including elastic scattering, ionization cross section and total excitation cross section in case that electrons with certain energy are put in the liquid-density water. In order to understand the effect of radiation when the particle flux is injected in the human body like radiotherapy using accelerator ...

2003-08-17

432

Focused ion beam assisted three-dimensional rock imaging at submicron scale  

Energy Technology Data Exchange (ETDEWEB)

Computation of effective flow properties of fluids in porous media based on three dimensional (3D) pore structure information has become more successful in the last few years, due to both improvements in the input data and the network models. Computed X-ray microtomography has been successful in 3D pore imaging at micron scale, which is adequate for many sandstones. For other rocks of economic interest, such as chalk and diatomite, submicron resolution is needed in order to resolve the 3D-pore structure. To achieve submicron resolution, a new method of sample serial sectioning and imaging using Focused Ion Beam (FIB) technology has been developed and 3D pore images of the pore system for diatomite and chalk have been obtained. FIB was used in the milling of layers as wide as 50 micrometers and as thin as 100 nanometers by sputtering of atoms from the sample surface. The focused ion beam, consisting of gallium ions (Ga+) ...

2003-05-09

433

Focused Ion Beam Recovery of Hypervelocity Impact Residue in Experimental Craters on Metallic Foils.  

Energy Technology Data Exchange (ETDEWEB)

The Stardust sample return capsule will return to Earth in January 2006 with primitive debris collected from Comet 81P/Wild-2 during the fly-by encounter in 2004. In addition to the cometary particles embedded in low-density silica aerogel, there will be microcraters preserved in the Al foils (1100 series; 100 {micro}m thick) that are wrapped around the sample tray assembly. Soda lime spheres ({approx}49 {micro}m in diameter) have been accelerated with a Light Gas Gun into flight-grade Al foils at 6.35 km s{sup -1} to simulate the capture of cometary debris. The experimental craters have been analyzed using scanning electron microscopy (SEM) and x-ray energy dispersive spectroscopy (EDX) to locate and characterize remnants of the projectile material remaining within the craters. In addition, ion beam induced secondary electron imaging has proven particularly useful in identifying areas within the craters that contain residue material. Finally, ...

2005-11-04

434

Design experience of the JRR-2 BNCT facility in JAERI  

Energy Technology Data Exchange (ETDEWEB)

The thermal neutron column of the JRR-2 reactor was remodelled in order to install a medical irradiation facility. The design experience and the cource of this remodelling are presented. At first, the thermal neutron flux was lower than expected, and the expected radiation condition was achieved by the following improvements: (1) removal of graphite from the thermal neutron column to increase the neutron flux, (2) twice increase of bismuth shielding and the shift of its position to improve the shielding effect against gamma ray, (3) application of B{sub 4}C rubber on the both surfaces of the shielding door to suppress the secondary gamma ray generation from the structural materials, (4) LiF tiles are applied on the inner face of the neutron beam exit hole to suppress the secondary gamma ray from the beam exit, and (5) installment a cone-shape polyethylene collimator to relieve the decay of thermal neutron. After the ...

1994-06-01

435

Testing measurements at horizontal channels of the MARIA reactor performed using neutron spectrometers; Pomiary testowe przy kanalach poziomych reaktora MARIA wykonane przy uzyciu spektrometrow neutronow  

Energy Technology Data Exchange (ETDEWEB)

By means of neutron diffraction, using the standard polycrystalline sample of Al{sub 2}O{sub 3}, measurements on three (of four spectrometers) already installed in the front of horizontal channels of MARIA reactor have been performed. Basing on these experiments as well as on activation measurements carried out earlier, the fluxes of monoenergetic neutrons have been estimated. These experiments allowed to determine (for a given geometry and kind of monochromators chosen) the resolution efficiency of instruments and high order contamination in the reflected beam. With the help of polycrystalline vanadium and TbBr{sub 3} sample, the possibility of studies using the inelastic scattering process have been tested. (author) 7 refs, 15 figs, 7 tabs

1997-12-31

436

Study of Zircaloy-2 corrosion in high temperature water using ion beam methods  

Energy Technology Data Exchange (ETDEWEB)

Experiments have been carried out in water at 355 C to study transport of oxygen and hydrogen (as deuterium) in growing corrosion films. Composition of the films was also examined in 2.9 Mev and 3.9 Mev /alpha/-particle backscattering experiments. Corrosion occurs predominantly by oxygen diffusion through the film via grain boundary or similar short circuit diffusion paths, to form fresh oxide at the oxide metal interface. Increasing grain size within thick pre-breakaway films contributes to a decrease in diffusivity. The rate transition results from the generation of new diffusion pathways in previously protective oxide. Unexpectedly high concentrations of deuterium were observed. 26 refs.

1981-10-01

437

Absolute cross sections for near-threshold electron-impact excitation of the 3s"2"1S#->#3s3p"1P and 3s"2"1S#->#3s3p"3P transitions in Si"2"+  

International Nuclear Information System (INIS)

Absolute total cross sections for electron-impact excitation of the 3s"2"1S#->#3s3p"3P and 3s"2"1S#->#3s3p"1P transitions in Si"2"+ were measured using the merged electron-ion beams energy-loss technique. The results are compared to R-matrix close-coupling theory, which predicts a strong resonance enhancement of the cross section near the threshold for excitation of the "3P state and this is confirmed by the experiments. The observed disagreement between theory and experiment for the dipole excitation is suggested to be due to resonance interference. copyright 1997 The American Physical Society.

438

radiation hardening and microstructure evolution in austenitic chromium-nickel steel under various type irradiation  

International Nuclear Information System (INIS)

A study was made into microstructure and hardening in austenitic stainless steel 0Kh18N10T irradiated with neon ions (230 MeV) and neutrons (E_n > 0.1 MeV). The experiments were accomplished using an external beam of U-400 cyclotron (Dubna) and EWA reactor (Poland). The dependences of tensile properties, hardening index, microstructure, dislocation density on damaging dose were determined. An attempt is made to reveal the correlation between an yield strength increment and defect cluster accumulation. The interpretation of variations of mechanical properties and microstructure under irradiation is given.

439

The double crystal technique - its application to resconstructed InSb (001) and Xe layers  

International Nuclear Information System (INIS)

The early work of Stern has been reviewed briefly along with some of our experiments carried out later with similar geometrical arrangements in order to highlight his successes at the time and the future developments of his findings and predictions. The double crystal technique, developed by Stern has been used for energy analysis of He beams and results are shown for scattering from a rough reconstructed (001) InSb surface and Xe adsorbed layers. Surface phonons were not observed in the case of InSb probably as a result of the rough surface. (orig.).

1988-01-01

440

The CTOF measurements and Monte Carlo analyses of neutron spectra for backward direction from iron target irradiated by protons with energies from 400 to 1200 MeV  

CERN Document Server

A calorimetric-time-of-flight (CTOF) technique was used for real-time, high-precision measurement of neutron spectrum at the angle of 175 degrees from the initial proton beam direction, which hits a face plane of a cylindrical iron target of 20 cm in diameter and 25 cm thick. A comparison was performed between the neutron spectra predicted by the MARS and the MCNPX code systems and measured by experiments for 0.4-, 0.6-, 0.8-, 1.0-, and 1.2-GeV protons.

2009-01-01

441

The AMS-02 electromagnetic calorimeter  

CERN Document Server

The Electromagnetic Calorimeter (ECAL) of the AMS-02 experiment is a lead-scintillating fibers sampling calorimeter characterized by high granularity that allows to image the longitudinal and lateral showers development, a key issue to provide high electron/hadron discrimination. The light collection system and the FE electronics are designed to let the calorimeter operate over a wide energy range from few GeV up to 1 TeV. A full-scale prototype of the e.m. calorimeter was tested at CERN in October 2001 using electrons and pions beams with energy ranging from 3 to 100 GeV. Effective sampling thickness, linearity and energy resolution were measured. (8 refs).

2002-01-01

442

Studies of Plasma Confinement in GOL-3 Multi-mirror Trap  

International Nuclear Information System (INIS)

Recent results of the experiments at GOL-3 facility are presented. Plasma with a density of 1014...1016 cm-3 is confined in a 12-meter-long solenoid, which comprises 55 corrugation cells with mirror ratio Bmax/B min=4.8/3.2 T. The plasma is heated up to 2...4 keV temperature by a high power relativistic electron beam (?1 MeV, ? 330 kA, ?8?s, ?120 kJ) injected through one of the ends. Mechanism of experimentally observed fast ion heating, issued of plasma stability and confinement are discussed.

2006-01-01

443

Proton and deuteron spin structure function measurements in the resonance region  

Energy Technology Data Exchange (ETDEWEB)

The RSS collaboration has measured the spin structure functions of the proton and the deuteron at Jefferson Lab using the Hall C HMS spectrometer, a polarized electron beam and a polarized solid target. The asymmetries A and A were measured in the region of the nucleon resonances (0.82 GeV < W < 1.98 GeV) at an average four momentum transfer of Q2 = 1.3 GeV2. The extracted spin structure functions and their kinematic dependence will make a significant contribution in the study of higher-twist effects and polarized duality tests. A description of the experiment and the latest findings of the analysis will be presented.

2003-07-01

444

On some mechanisms of 27.2 MeV #alpha#-particle interaction with carbon nuclei  

International Nuclear Information System (INIS)

Using U-120 cyclotron in the course of correlation experiment one studied mechanisms of excitation and decay of "1"2C nucleus states resulting from irradiation of deuterium-polyethylene target by 27.2 MeV energy #alpha#-particle beam via recording of #alpha#-#alpha#-coincidence simultaneously with investigations of #alpha# + d-interactions. Production of "1"2C excited states decaying with the escape of #alpha#-particle and "8Be nucleus in the ground and the excited states is the basic mechanism of the studied #alpha# + "1"2C interaction

2001-05-01

445

Laser photoelectron spectroscopy of ions. Progress report, August 1, 1982-July 31, 1983  

Energy Technology Data Exchange (ETDEWEB)

We have undertaken a program which measures the photoelectron spectra of negative-ion beams. This experiment has afforded us direct information about these ions and the corresponding neutral radicals. Several ions and numerous radicals are believed to be crucial intermediates in combustion processes and flame chemistry. We have fabricated a spectrometer which directly measures electron affinities (EA). Knowledge of the EA and gas-phase acidity of a radical has enabled us to deduce several radical heats of formation and bond strengths.

1983-03-01

446

Forward directed Smith-Purcell radiation from relativistic electrons  

International Nuclear Information System (INIS)

The requirements for the generation of forward directed Smith-Purcell emission from relativistic electrons are introduced, and the first experimental evidence of this phenomenon is presented. The experiments were conducted with a 2.8 MeV/c electron beam interacting with a 1 cm period grating. Radiation emitted in two bands with wavelengths ranging from 600 to 650 #mu#m and 1.2 to 1.7 mm were measured. Grating period to wavelength ratios were as high as 16. The measured intensities are higher than that predicted by incoherent emission.

447

Experimental generation of non-Kolmogorov turbulence using a liquid crystal spatial light modulator  

Science.gov (United States)

Several experiments showed that the classical Kolmogorov power spectral density of the refractive-index sometimes does not properly describe the statistics of the atmosphere. In this paper we show an experimental testbed able to generate non-classical Kolmogorov turbulence by using a liquid crystal spatial light modulator. The testbed is used at Naval Postgraduate School for laboratory investigation of laser beam propagation in maritime environment where a power law different from classical Kolmogorov, 11/ 3, could be present. Applications of this testbed are ship to-ship free space optical communication, imaging and high energy laser weapons.

2011-09-01

448

Dependence of laser assisted cleaning of clad surfaces on the laser fluence  

International Nuclear Information System (INIS)

The decontamination factor is studied as a function of laser fluence for three kinds of clad surfaces viz., plain zircaloy, autoclaved zircaloy and SS with cesium as the test contamination. It has been found that the decontamination factor exhibits a maximal behaviour with the laser fluence and its maximum value occurs at different laser fluences in the three cases. The maximal behaviour is attributed to reduced coupling of energy from the laser beam to the substrate due to the initiation of surface-assisted optical breakdown. The results obtained in the experiment carried out in helium environment qualitatively support this explanation (author)

2005-11-01

449

Study of proton therapy on malignant tumors. Effects in twenty-four hours after proton irradiation  

Energy Technology Data Exchange (ETDEWEB)

We irradiated proton beams on the ears of rabbits and the Harding-Passey mouse melanoma and observed their morphological change. We used 52 MeV proton beams from the INS-FM cyclotron. We adjusted the energy of the proton beams to be at the plateau part of the Bragg curve, at the half-way point of the Bragg peak, and at the Bragg peak. The amount of radiation was 5000rad in each case. The Harding-Passey mouse melanoma was transplanted into the subcutan of a three week old mouse. In this experiment, we used tumors, the diameter of which grew up to 1.5-2cm in 2-3 weeks after the transplantation. Using the jroscope, we observed both lightly and severely damaged cells. Using proton irradiation with the Bragg peak located at depth of 1mm in the rabbit's ears, we studied the change in the tissue. Irradiated epidermis fell off and was eroded because of radiation damage, but the rear surface of the ...

1983-01-01

450

Ultracold neutrons  

International Nuclear Information System (INIS)

In 1959 Zeldovich pointed out to the possibility of storage in a closed vessel of very slow neutrons with energies below less than or equal to 10"-"7 eV noting that one may achieve the storage time up to the lifetime of a free neutron before #beta#-decay (approx.10"3 sec). This possibility is due to the effective repulsing potential which describes the interaction of slow neutrons with many substances employing a strong suppression of inelastic processes in the reflection of ultracold neutrons (UCN). In a series of experiments beginning 1968 the effective methods were developed of obtaining pure UCN beams from the maxwellian spectrum of thermal neutrons. The UCN beams of intensity about 10"3 n/sec and density up to 10"2 n/liter were obtained at the reactors with thermal neutron flux of 5 x 10"1"3 n/cm"2 sec. Such UCN beam parameters allow to measure easily the UCN storage time in different vessels and ...

1976-07-06

451

In situ corrosion studies on selected high level waste packaging materials under simulated disposal conditions in rock salt formations  

International Nuclear Information System (INIS)

This paper reports about in-situ corrosion studies on selected materials for long-term resistant high-level waste (HLW) packagings acting as a barrier in a rock salt repository. The materials (Ti 99.8-Pd, Hastelloy C4 and five iron-base materials) were investigated in heated boreholes in the Asse salt mine under simulated HLW disposal conditions prevailing in normal operation of repository and in certain accident scenarios. The experiments under normal operating conditions were performed at temperatures of 120 deg. C to 210 deg. C (vertical temperature profile in the boreholes) without and with gamma irradiation (3#centre dot#10"2 Gy/h, Co-60 source) within the framework of the German/US Brine Migration Test. In these experiments only small amounts of migrated brine inclusions (NaCl-rich) from the rock salt were present as corrosion medium. In the experiments carried out under simulated accident conditions with intrusion of ...

1993-02-01

452

A Liquid Parahydrogen Target for the Measurement of a Parity-violating Gamma Asymmetry in Polarized Neutron Capture on Protons  

Energy Technology Data Exchange (ETDEWEB)

A 16 l liquid parahydrogen target has been developed for a measurement of the parity-violating {gamma}-asymmetry in the capture of polarized cold neutrons on protons in the {rvec n} + p {yields} d + {gamma} reaction by the NPDGamma collaboration. The target system was carefully designed to meet the stringent requirements on systematic effects for the experiment and also to satisfy hydrogen safety requirements. The target was designed to preserve the neutron polarization during neutron scattering on liquid hydrogen (LH{sub 2}), optimize the statistical sensitivity to the {rvec n} + p {yields} d + {gamma} reaction, minimize backgrounds coming from neutron interaction with the beam windows of the target cryostat, minimize LH{sub 2} density fluctuations which can introduce extra noise in the gamma asymmetry signal, and control systematic effects. The target incorporates two mechanical refrigerators, two ortho-para convertors, an aluminum cryostat, ...

2010-05-01

453

Time-dependent 3-D dterministic transport on parallel architectures using Dantsys/MPI  

Energy Technology Data Exchange (ETDEWEB)

In addition to the ability to solve the static transport equation, we have also incorporated time dependence into our parallel 3-D S{sub {ital N}} code DANTSYS/MPI. Using a semi-implicit scheme, DANTSYS/MPI is capable of performing time-dependent calculations for both fissioning and pure source driven problems. We have applied this to various types of problems such as nuclear well logging and prompt fission experiments. This paper describes the form of the time- dependent equations implemented, their solution strategies in DANTSYS/MPI including iteration acceleration, and the strategies used for time-step control. Results are presented for a model nuclear well logging calculation.

1996-12-31

454

Response characteristics of base-isolated structure with silicone rubber bearings  

International Nuclear Information System (INIS)

More than sixty base-isolated buildings have been built in Japan. A number of base-isolation systems were considered in our research, which was intended to establish the effectiveness of base-isolation systems. We conducted research on silicone rubber bearings. Generally, silicone rubber is durable and its characteristics are not dependent on the temperature within the relevant design range. The first part of the report covers material and elements testing. After the bearings were installed in the building, we performed forced vibration tests in both the horizontal and vertical directions. These test results form the next section. After several experiments, we carried out earthquake observations. We report on the effectiveness of the system in reducing response acceleration during a small displacement. This system was installed in the building in March 1992

1993-08-15

455

KLOE-2 experiment at DA$\\Phi$NE upgraded in luminosity  

CERN Document Server

Prospective presentation is given for the experimental program of the KLOE-2 Collaboration, to be performed using the DA$\\Phi$NE $e^+e^-$ collider upgraded in luminosity. Data with the total luminosity of 25 fb$^{-1}$ are aimed to be collected in 3 years. Major modifications of the accelerator and the spectrometer are described. The KLOE-2 physics program contains: CKM unitarity and lepton universality tests, $\\gamma\\gamma$ physics, search for quantum decoherence and testing CPT conservation, low-energy QCD, rare kaon decays, physics of $\\eta$ and $\\eta^\\prime$, structure of low-mass scalars, contribution of vacuum polarization to $(g-2)_{\\mu}$, possible search for WIMP dark matter. In this paper only selected physics subjects are reported.

2011-01-01

456

High-power rf-pulsed modulators for the Los Alamos free-electron laser  

Energy Technology Data Exchange (ETDEWEB)

In the rf-driven free-electron laser (FEL) at the Los Alamos National Laboratory, there are two pulsed-power rf modulators as sources for two tandem, side-coupled 20-MeV linear accelerators. The rf power used to control the cavity fields is supplied by two 5.5-MW modulating anode klystrons operating at a center frequency of 1300.2 MHz. The modulation of the 125 kV klystron is achieved by using a triode switch tube that provides a pulse width up to 300 ..mu..s and a pulse repetition rate up to 10 Hz. This paper describes the present configuration of these two duplicate systems and presents plans for meeting the requirements of future rf FEL experiments at Los Alamos. 12 refs., 5 figs.

1987-09-01

457

Flame propagation characteristics and flame structures of zirconium particle cloud in a small-scale chamber  

British Library Electronic Table of Contents (United Kingdom)

Flame propagating through zirconium particle cloud in a small-scale vertical rectangle chamber was investigated experimentally. In the experiments, the zirconium quoted 99% purity was used and the diameter of particles was distributed 1?22 ?m. The zirconium dust was dispersed into the chamber by air flow and ignited by an electrode spark. A high-speed video camera was used to record the images of the propagating flame. Micro-thermocouples, schlieren optical system and microscopic lens were used to obtain temperature profiles and flame structure, respectively. Based on the experimental results, flame propagation characteristics and flame structure of zirconium particle cloud were analyzed. The propagation velocity of the flame is quite slow in the initial 14 ms and then accelerates to maxim...

2010-01-01

458

Xebra electric vehicle. Case study, ZAP - USA; Lithium-ion battery  

Energy Technology Data Exchange (ETDEWEB)

The Zap Xebra Electric Truck is fitted with 23 Li-Ion Cells from China providing a nominal voltage of 72V and a nominal capacity of 400AH. The Li-Ion cells weighing 13 kg each, making the total weight of the battery pack approx. 300 kg. A Battery Management System (BMS) from Lithium Balance is installed to ensure safe, reliable and maximum performance of the batteries. The testing of the Zap Xebra Electric Truck included two kinds of test, a Stop-and-Go test and a range test. Our Stop-and-Go test consists of accelerating the vehicle for 1 km (0.62mi), braking and then accelerate for 1 km(0.62mi), counting the number of stop-and-goes. Our range test is a real-world test including stops, accelerations, driving in the city and in the countryside, going uphill and downhill. This test shows the average range that the end user will experience. Looking at the results of both the tests and comparing them with ...

2008-07-01

459

Effect of chlorides on the corrosion behaviour of mild steel  

International Nuclear Information System (INIS)

In PWR's steam generators, ''denting'' resulted from corrosion of support plate material, carbon steel is an important problem. The role of chlorides in corrosion acceleration of mild steel was studied. Corrosion tests were conducted at temperature from 100"0C to 280"0C in deaerated solutions of NaCl and MgCl_2 which are main content of sea water. 1) Solution of MgCl_2 was more corrosive than that of NaCl. The more increased in concentration of each chloride solution, the more corrosive in MgCl_2 soln. but the less corrosive in NaCl soln. 2) The rate of corrosion in the mixed solution of NaCl and MgCl_2 was governed by the concentration of MgCl_2 soln. The corrosion behaviour in sea water was suggested to be not controlled by NaCl but by MgCl_2. 3) Acidification of MgCl_2 soln. could be evaluated by experiment at 100"0C, the degree of acidification increased with increasing the concentration. However, the value of pH during corrosion was kept ...

460

Stabilization of synchrotron radiation beam at HASYLAB  

Energy Technology Data Exchange (ETDEWEB)

At DORIS II/HASYLAB a vertical beam position control system is in regular operation. It controls the position and angle of a photon beam simultaneously, and can stabilize beam movements up to frequencies of 0.1 Hz. To suppress beam vibrations up to 50 Hz and above, a prototype beam stabilization system for these frequencies was built and tested successfully. The present beam oscillations at the HASYLAB beamlines are explained, the quality of the beam position control system and the results of the prototype test are presented.

1989-07-01

462

Beam Diagnostic System for High Intensity Proton Linac at KAERI  

CERN Document Server

Beam Diagnostic System for High Intensity Proton Linac at KAERI

2003-01-01

463

Structure and kinetics of Sn whisker growth on Pb-free solder finish  

Energy Technology Data Exchange (ETDEWEB)

Standard Leadframes used in surface mount technology are finished with a layer of eutectic SnPb for passivation and for enhancing solder wetting during reflow. When eutectic SnPb is replaced by Pb-free solder, especially the eutectic SnCu, a large number of Sn whiskers are found on the Pb-free finish. Some of the whiskers are long enough to become shorts between the neighboring legs of the leadframe. How to suppress their growth and how to perform accelerated test of Sn whisker growth are crucial reliability issues in the electronic packaging industry. In this paper, we report the study of spontaneous Sn whisker growth at room temperature on eutectic SnCu and pure Sn finishes. Both compressive stress and surface oxide on Sn are necessary conditions for whisker growth. Structure and stress analyses by using the micro-diffraction in synchrotron radiation are reported. Cross-sectional electron microscopy, with samples prepared by focused ion beam, ...

2002-07-11

464

State-in-the-art of applications of shock wave research and its future; Shogekiha no oyo gijutsu no genjo to shorai  

Energy Technology Data Exchange (ETDEWEB)

A shock wave appears when the release of accumulated energy is instantaneous. For instance, it accompanies gunpowder explosion, electric discharge, laser beam convergence, collision of high-speed objects, release of high-pressure gas, and supersonic flight. The shock wave research center of Institute of Fluid Science, Tohoku University, is engaged in researches to elucidate the basics of various shock wave phenomena and to apply the fruit to engineering, science, and medicine. In this report, some examples of recent application studies at the center are described, and the trend of shock wave researches in the future is introduced. The ultimate state of the stagnation point of a nozzle flow simulating a reentry into the atmosphere is produced by shock wave compression in a free piston shock tube which is a ground-borne experimental apparatus. Los Alamos National Laboratory, U.S., succeeded in generating metallic hydrogen of a crystalline structure by subjecting ...

1999-03-15

465

Resent development by the use of neutron induced nuclear reaction  

International Nuclear Information System (INIS)

When the history of neutrons is considered, three large discoveries are recalled, that is, the discovery of neutrons by Chadwick in 1932, the discovery of the nuclear fission of uranium by Hahn and Strassmann in 1938, and the continuation of chain reaction in nuclear fission by Fermi and others in 1942. In neutron capture reaction, the reaction cross section can become very large. The fields of research, to which neutrons have contributed most as the experimental probe, are neutron activation analysis and neutron diffraction. The development of the prompt gamma ray analyzer at the JRR-3M in Japan Atomic Energy Research Institute is reported. This method eliminates the various defects in ordinary neutron activation analysis. By installing the cold neutron source with hydrogen cooling in the JRR-3M, the new field of research was opened. As the combination of a lead-moderated spectrometer and an electron beam type accelerator, the Kyoto University ...

1992-01-01

466

Proton exchange membranes prepared by grafting of styrene/divinylbenzene into crosslinked PTFE membranes  

International Nuclear Information System (INIS)

Thin PTFE membranes were prepared by coating the PTFE dispersion onto the aluminum films. Thus the thin crosslinked PTFE (RX-PTFE) membranes were obtained by means of electron beam irradiation above the melting temperature of PTFE under oxygen-free atmosphere. The RX-PTFE membranes were pre-irradiated and grafted by styrene with or without divinylbenzene (DVB) in liquid phase. The existence of DVB accelerated the initial grafting rate. The styrene grafted RX-PTFE membranes are white colored, on the other hand, the styrene/DVB grafted RX-PTFE membranes are colorless. The proton exchange membranes (PEMs) were obtained by sulfonating the grafted membranes using chlorosulfonic acid. The ion exchange capacity (IEC) values of the PEMs ranging from 1.5 to 2.8 meq/g were obtained. The PEMs made from the styrene/DVB grafted membranes showed higher chemical stability than those of the styrene grafted membranes under oxidative circumstance.

2005-07-01

467

MicroDiffraction in the Scanning Electron Microscope (SEM)  

Science.gov (United States)

The identification of crystallographic phases in the scanning electron microscope (SEM) has been limited by the lack of a simple way to obtain electron diffraction data of an unknown while observing the micro structure of the specimen. With the development of Charge Coupled Device (CCD) based detectors, backscattered electron Kikuchi patterns (BEKP), alternately referred to as electron backscattered diffraction patterns (EBSP), can be easily collected. Previously, BEKP has been limited to crystallographic orientation studies due to the poor pattern quality collected with video rate detector systems. With CCD detectors, a typical BEKP can now be acquired from a micron or sub-micron-sized crystal using an exposure time of 1-10 seconds with an accelerating voltage of 10-40 kV and a beam current as low as 0.1 nA. Crystallographic phase analysis using BEKP is unique in that the properly equipped SEM permits high magnification images, BEKP`s, and ...

1997-12-31

468

Irradiation of food  

International Nuclear Information System (INIS)

Processing of food with ionizing radiation is a method suitable to enhance shelf-life and hygienic quality. Up to a dose of 10 kGy the method is considered wholesome. In many countries the practical use of food irradiation is increasing, however, in the Federal Republic of Germany the process is strictly forbidden. Applications and methods for radiation processing of food are compiled, limits and prospects are explained, and advantages and disadvantages are compared with traditional methods. Identification of irradiated foods and dosimetry and process control for radiation processing of food are areas where further research is needed. Continuous processing of particulate foods in bulk is an application where electron accelerators might be profitable. Beam parameters and velocity distribution of food particles in the treatment area can be matched for an effective result. Thus, dose distribution can be adjusted for homogeneous treatment and at ...

469

Development of large-capacity refrigeration at 1.8 K for the Large Hadron Collider at CERN  

CERN Document Server

CERN, the European Laboratory for Particle Physics, is working towards the construction of the Large Hadron Collider (LHC), a high-energy, high-luminosity particle accelerator and collider [1] of 26.7 km circumference, due to start producing frontier physics, by bringing into collision intense proton and ion beams with centre-of-mass energies in the TeV-per-constituent range, at the beginning of the next century. The key technology for achieving this ambitious scientific goal at economically acceptable cost is the use of high-field superconducting magnets using Nb-Ti conductor operating in superfluid helium [2]. To maintain the some 25 km of bending and focusing magnets at their operating temperature of 1.9 K, the LHC cryogenic system will have to produce an unprecedented total refrigeration capacity of about 20 kW at 1.8 K, in eight cryogenic plants distributed around the machine circumference [3]. This has requested the undertaking of an ...

1996-01-01

470

Brookhaven highlights. [Fiscal year 1992, October 1, 1991--September 30, 1992  

Energy Technology Data Exchange (ETDEWEB)

This publication provides a broad overview of the research programs and efforts being conducted, built, designed, and planned at Brookhaven National Laboratory. This work covers a broad range of scientific disciplines. Major facilities include the Alternating Gradient Synchrotron (AGS), with its newly completed booster, the National Synchrotron Light Source (NSLS), the High Flux Beam Reactor (HFBR), and the RHIC, which is under construction. Departments within the laboratory include the AGS department, accelerator development, physics, chemistry, biology, NSLS, medical, nuclear energy, and interdepartmental research efforts. Research ranges from the pure sciences, in nuclear physics and high energy physics as one example, to environmental work in applied science to study climatic effects, from efforts in biology which are a component of the human genome project to the study, production, and characterization of new materials. The paper provides ...

1992-12-31

471

Brookhaven highlights  

Energy Technology Data Exchange (ETDEWEB)

This publication provides a broad overview of the research programs and efforts being conducted, built, designed, and planned at Brookhaven National Laboratory. This work covers a broad range of scientific disciplines. Major facilities include the Alternating Gradient Synchrotron (AGS), with its newly completed booster, the National Synchrotron Light Source (NSLS), the High Flux Beam Reactor (HFBR), and the RHIC, which is under construction. Departments within the laboratory include the AGS department, accelerator development, physics, chemistry, biology, NSLS, medical, nuclear energy, and interdepartmental research efforts. Research ranges from the pure sciences, in nuclear physics and high energy physics as one example, to environmental work in applied science to study climatic effects, from efforts in biology which are a component of the human genome project to the study, production, and characterization of new materials. The paper provides ...

1992-01-01

472

Panel session: Transport of negative ion beams  

Energy Technology Data Exchange (ETDEWEB)

Transport of negative ion beams through plasma is reviewed. The effect of space charge on beam stability and beam emittance is discussed. The approaches to the beam transport problem developed at Los Alamos, Berkeley, Oak Ridge and Culham Laboratory are intercompared. (AIP)

1987-07-30

473

Monte Carlo treatment planning for photon and electron beams  

International Nuclear Information System (INIS)

During the last few decades, accuracy in photon and electron radiotherapy has increased substantially. This is partly due to enhanced linear accelerator technology, providing more flexibility in field definition (e.g. the usage of computer-controlled dynamic multileaf collimators), which led to intensity modulated radiotherapy (IMRT). Important improvements have also been made in the treatment planning process, more specifically in the dose calculations. Originally, dose calculations relied heavily on analytic, semi-analytic and empirical algorithms. The more accurate convolution/superposition codes use pre-calculated Monte Carlo dose 'kernels' partly accounting for tissue density heterogeneities. It is generally recognized that the Monte Carlo method is able to increase accuracy even further. Since the second half of the 1990s, several Monte Carlo dose engines for radiotherapy treatment planning have been introduced. To enable the use of a Monte Carlo treatment ...

2007-04-01

474

Characterization of a time-of-flight mass spectrometer and its applications in the study of solid surfaces; Charakterisierung eines Flugzeitmassenspektrometers und seine Anwendungen in der Festkoerperoberflaechenuntersuchung  

Energy Technology Data Exchange (ETDEWEB)

The object and the purpose of the present work was to develop, to assemble and to start running a new TOF (time of flight) mass spectrometer for imaging SNMS analytic which is optimized for the analysis of highly molecular secondary ions. The most important purpose was the characterization of the TOF mass spectrometer. The obtained mass spectra of indium, tantalum and silver clusters reflect the excellent properties of the TOF mass spectrometer for the detection of large clusters with good detection efficiency up to masses of 16000 amu. The possibility of the deflection of selected saturated atom and cluster peaks serves for further improvement of the detection efficiency for large molecules. The accessible mass resolution was determined to be of the order of m/{delta}m=1000 in the high mass region. Numerous measurements were carried out to characterize the useful yield of this spectrometer. For a best possible adaptation of the TOF mass spectrometer for the detection of highly ...

2006-12-21

475

Transient analysis of blowdown thrust force under PWR LOCA conditions  

Energy Technology Data Exchange (ETDEWEB)

The analytical results of blowdown characteristics and its thrust force were compared with the experiment, which were performed as pipe whip tests under the PWR LOCA conditions on the hypothetical accident of guillotine break of pipes. The blowdown thrust force was obtained by the integral momentum equation about single-phase flow, homogeneous and separated two-phase flow, assuming critical pressure at the exit if critical flow condition was satisfied. The following results are obtained: (1) The node-junction method is useful for the analysis of water hammer phenomena and of the blowdown thrust force. (2) The Henry-Fauske model for subcooled critical flow is effective for the analysis of the maximum thrust force under the PWR LOCA conditions. The jet thrust parameter of analysis and experiment is 1.08. (3) The thrust parameter of saturated blowdown has the same one with the value under pressurized condition when the stagnant pressure is chosen ...

1982-09-01

476

Transient analysis of blowdown thrust force under PWR LOCA  

Energy Technology Data Exchange (ETDEWEB)

The analytical results of blowdown characteristics and thrust forces were compared with the experiments, which were performed as pipe whip and jet discharge tests under the PWR LOCA conditions. The blowdown thrust forces were obtained by Navier-Stokes momentum equation for a single-phase, homogeneous and separated two-phase flow, assuming critical pressure at the exit if a critical flow condition was satisfied. The following results are obtained: (1) The node-junction method is useful for both the analyses of the blowdown thrust force and of the water hammer phenomena. (2) The Henry-Fauske model for subcooled critical flow is effective for the analysis of the maximum thrust force under the PWR LOCA conditions. The jet thrust parameter of the analysis and experiment is equal to 1.08. (3) The thrust parameter of saturated blowdown has the same one with the value under pressurized condition when the stagnant pressure is chosen as the saturated ...

1983-04-01

477

Modeling jet penetration in glass  

Energy Technology Data Exchange (ETDEWEB)

It is well known that composite armors, consisting of glass elements confined with metallic tampers, are extraordinarily effective against shaped charge attack. Early experiments showed that jets fired against glass targets appeared to be bombarded by tiny fragments that destroyed alignment and reduced residual jet penetration. This result was attributed to an elastic rebound effect in which the outward radial motion of the target around the jet periphery was supposed to be arrested by tensile hoop stresses which developed behind the divergent shock front. Glass fragments were then accelerated radially inward and these destabilized the jet. To sustain the large tensile hoop stresses required, the glass must not have been fractured by the initial shock, behind which the stress state is typically well above the Hugoniot elastic limit. Modeling the penetration of a jet into glass requires not only determining the spall strength, i.e., the tensile ...

1990-04-05

478

Measuring the quark contribution to the proton spin through. nu. p yields. nu. p  

Energy Technology Data Exchange (ETDEWEB)

The LSND (Liquid Scintillator Neutrino Detector) experiment will be performed at LAMPF in the next several years. The main goal of the experiment is to search for {nu}{sub {mu}}-{nu}{sub e} oscillations with high sensitivity; however, an increasingly important by-product of this search is to measure {nu}p {yields} {nu}p elastic scattering and determine the strange quark contribution, {Delta}s, to the spin of the proton. With the 800-MeV proton energy of LAMPF, neutrinos are produced from pion decay-in-flight with an average energy of about 150 MeV. This energy is sufficiently high so that the {nu}p {yields} {nu}p cross section is large and is sufficiently low so that the low Q{sup 2} approximation (Q{sup 2} {much lt} m{sub p}{sup 2}) is valid and the cross section can be expressed in a simple form dependent upon {Delta}s as the only unknown. LAMPF with its 1-mA proton intensity is, therefore, an ideal accelerator to perform ...

1991-01-01

479

Gene expression analysis after low dose ionising radiation exposure of the developing organism  

International Nuclear Information System (INIS)

Measuring gene expression using microarrays is relevant to many areas of biology and medicine, such as follow up of developmental stages and diseases onset, and treatment study. Since there can be tens of thousands of distinct probes on an array, each micro array experiment can accomplish the equivalent number of genetic tests in parallel. Arrays have therefore dramatically accelerated many types of investigations. For example, microarrays can be used to identify stress response genes by comparing gene expression in challenged versus normal cells. In the Molecular and Cellular Biology lab (MCB), the micro array experiments are performed within the Genomic Platform, fully equipped to analyse either the behaviour of bacteria during long space flight, the effect of low dose ionising radiation on the developing organism in mice, or the human individual radiation sensitivity. For the low dose effect, two main stages of ...

2007-09-01

480

Commercializing research: the leadership challenges for the 21st century  

International Nuclear Information System (INIS)

R and D today is a large industry that consumes vast amounts of public and private funds in most countries. It is becoming increasingly evident that technology transfer and the commercialization of research done at universities and government funded research laboratories must be a key element of their comprehensive strategic plan. It involves using a verified and organized knowledge and research to develop commercially viable products. It requires a visionary leader with effective project management skills to manage and motivate a team of scientists and engineers, otherwise even a top rated researcher will enervate and wither within the walls of research laboratories. This paper will highlight the importance, challenges and techniques of commercializing technology from accelerator research laboratories. It will provide an overview of the requirements of scientific leadership for both commercialization of research and technology, together with some case studies ...

2000-06-26

481

Clear liquor scrubbing with anhydrite production. Fourth quarter 1996 technical progress report  

Energy Technology Data Exchange (ETDEWEB)

This project is part of PETC`s Advanced Power Systems Program, whose mission is to accelerate the commercialization of affordable, high- efficiency, low emission, coal-fueled electric generating technologies. A process concept - Clear Liquor Scrubbing with Anhydrite Production - was proposed and accepted by PETC as a Phase I project in its Mega-PRDA program. the project integrated three process operations - chloride control upstream of the flue gas desulfurization (FGD) system, a clear liquor process for enhanced SO{sub 2} removal performance, and production of anhydrite (anhydrous calcium sulfate) rather than calcium sulfite or gypsum (calcium sulfate dihydrate). The first step in the project was to perform batch and flow-through experiments in the laboratory to confirm theoretical calculations and preliminary laboratory results concerning anhydrite formation, these laboratory experiments were designed to prove that ...

1997-02-03

482

Mott-Schwinger Scattering of Polarized Low Energy Neutrons up to Thermal Energies  

Energy Technology Data Exchange (ETDEWEB)

The availability of new, high-intensity, cold and thermal neutron sources has opened the possibility of performing high-precision fundamental neutron physics experiments, including measurements that study the hadronic weak interaction and standard model test measurements, using neutron decay. The observables in these experiments are usually correlated with the direction of neutron polarization and are often very small (10 8 10 6). Mott-Schwinger scattering of polarized neutrons can produce spin-dependent shifts in beam centroids, which has the potential to produce significant systematic effects for these types of experiments. An accurate calculation of this process for neutral atoms and basic molecules has not been carried out for low neutron energies. In this work, we derive a general expression for the electromagnetic (Mott-Schwinger) contributions to the analyzing power for low-energy neutron ...

2008-10-01

483

Optimization of shielding for a 60 MeV alpha particle accelerator  

International Nuclear Information System (INIS)

Optimization of radiation shielding for a medium energy accelerator with 60 MeV alpha ions is carried out using the cost-benefit approach. Cost optimum shield thicknesses are estimated for different operating conditions of the accelerator. (author). 5 refs, 1 tab.

1988-04-18

484

Accelerated hyperfractionation (AHF) compared to conventional fractionation (CF) in the postoperative radiotherapy of locally advanced head and neck cancer: influence of proliferation  

UK PubMed Central (United Kingdom)

Based on the assumption that an accelerated proliferation process prevails in tumour cell residues after surgery, the possibility that treatment acceleration would offer a therapeutic advantage in postoperative...Full Text Available

2002-02-12

485

Measurement of characteristics of an infrared free-electron laser with the L-band at Osaka University  

Energy Technology Data Exchange (ETDEWEB)

Free-electron laser (FEL) experiments have been conducted with the 38-MeV L-band electron linac at the Institute of Scientific and Industrial Research, Osaka University. It is a 1.3 GHz RF linac with a thermoionic gun, and equipped with two 12th and one 6th sub-harmonic prebunchers for producing the high-intensity single-bunch beam with a charge up to 67 nC/bunch. For oscillation experiments of FEL, the gun is replaced with that with a smaller cathode area in order to reduce the emittance of the beam. The normalized emittance has been measured to be 200 {pi} mm-mrad. The linac is operated in the long-pulse mode and one of the 12th sub-harmonic bunchers and the 6th sub-harmonic buncher are operated, so that the time duration of the macropulse is 4 {mu}s and the spacing between micropulses is 9.2 ns. The length of the micropulse is 30-40 ps and the charge in each micropulse is 2 nC. The electron ...

1995-12-31

486

Triple ion-beam studies of radiation damage in 9Cr2WVTa ferritic/martensitic steel  

Energy Technology Data Exchange (ETDEWEB)

To simulate radiation damage under a future Spallation Neutron Source (SNS) environment, irradiation experiments were conducted on a candidate 9Cr-2WVTa ferritic/martensitic steel using the Triple Ion Facility (TIF) at ORNL. Irradiation was conducted in single, dual, and triple ion beam modes using 3.5 MeV Fe{sup ++}, 360 keV He{sup +}, and 180 keV H{sup +} at 80, 200, and 350{degrees}C. These irradiations produced various defects comprising black dots, dislocation loops, line dislocations, and gas bubbles, which led to hardening. The largest increase in hardness, over 63 %, was observed after 50 dpa for triple beam irradiation conditions, revealing that both He and H are augmenting the hardening. Hardness increased less than 30 % after 30 dpa at 200{degrees}C by triple beams, compatible with neutron irradiation data from previous work which showed about a 30 % increase in yield strength after 27.2 dpa ...

1997-11-01

487

The free electron laser klystron amplifier concept  

International Nuclear Information System (INIS)

The simplest high gain free electron laser (FEL) amplifier concept is proposed. A klystron amplifier has the useful property that the various electronic processes take place in separate portions of the amplifier, rather than overlapping as in FEL amplifier with an uniform undulator. The klystron consists of two fundamental parts: succession of 2-3 cascades (modulator), and an output undulator (radiator) in which the modulated electron beam coherently radiates. Each cascade consists of uniform undulator and dispersion section. Unlike distributed optical klystrons, we have a high gain per cascade pass. This has a few consequences. First, klystron gain does not depend on the bunch compression in the injector linac, i.e. maximum gain per cascade pass at high peak beam current is the same at low peak beam current, without compression. Conventional, short-wavelength FEL amplifier and distributed optical klystron require electron ...

488

IMRT verification by three-dimensional dose reconstruction from portal beam measurements  

International Nuclear Information System (INIS)

A method of reconstructing three-dimensional, in vivo dose distributions delivered by intensity-modulated radiotherapy (IMRT) is presented. A proof-of-principle experiment is described where an inverse-planned IMRT treatment is delivered to an anthropomorphic phantom. The exact position of the phantom at the time of treatment is measured by acquiring megavoltage CT data with the treatment beam and a research prototype, flat-panel, electronic portal imaging device. Immediately following CT imaging, the planned IMRT beams are delivered using the multiple-static field technique. The delivered fluence is sampled using the same detector as for the CT data. The signal measured by the portal imaging device is converted to primary fluence using an iterative phantom-scatter estimation technique. This primary fluence is back-projected through the previously acquired megavoltage CT model of the phantom, with inverse attenuation ...

2002-08-01

489

Carbon beam irradiation of human monolayer cells  

Energy Technology Data Exchange (ETDEWEB)

The effect of the heavy particle irradiation on cell survival is different from that of X-ray irradiation. In Japan, heavy particles will be applied to cancer patients in the near future. This study was performed to determine the effect that carbon particle irradiation exerts to human monolayer cells in vitro, in comparison with the effect of 200 kVp X-ray. Two human cell lines, HeLaS3 and RMUG, were used. The irradiation was carried out by the RIKEN ring cyclotron and 200 kVp X-ray. The experimental procedure is explained. Also split dose experiment was carried out by applying equally divided doses at intervals of 2 - 4 hours. The Bragg curve of 135 MeV/n carbon beam through the lucite plates with different thickness is given. Thus the different LETs were obtained. The survival curves for 200 kVp X-ray and the various LETs of carbon beam are shown. The curves became steeper, and Do values decreased with increasing LETs in ...

1993-12-31

490

Accuracy of calculations for stereotactic radiotherapy of the lung. Comparison of dose calculation algorithms  

International Nuclear Information System (INIS)

The purpose of this study is to evaluate the accuracy of dose calculations by three algorithms. Depth dose, OPF (Output Factor) and dose profiles were measured in a heterogeneous phantom. These values were also calculated by three algorithms of the Batho power law (BPL), Equivalent-Tissue Air Ratio (ETAR) and Convolution superposition (CS). The data were obtained for 4, 6 and 10 MV photon beams with a linear accelerator (Varian 21EX). Field size ranged from 3 x 3 cm"2 to 10 x 10 cm"2. Dose profiles of beam penumbra were also measured by a 0.125 ml ionization chamber at the point of 8, 13 and 18 cm from the surface of the phantom at intervals of 1 mm. Differences between measured and calculated depth doses were within 2% in BPL and CS, but depth doses were overestimated in ETAR. OPFs were also overestimated with the error of more than 4% in ETAR. Absorbed dose calculated by CS were in agreement with the values measured by ...

2004-12-01

491

Proposal for the award of a blanket purchase contract for the supply of electronics subracks for the CERN accelerator control system  

CERN Document Server

Proposal for the award of a blanket purchase contract for the supply of electronics subracks for the CERN accelerator control system

2010-01-01

492

Background information on the high energy physics program and the proposed Stanford linear electron accelerator project  

CERN Document Server

Background information on the high energy physics program and the proposed Stanford linear electron accelerator project

1961-01-01

493

Accelerator technology program, January-June 1982. Status report  

International Nuclear Information System (INIS)

The major projects of the Los Alamos National Laboratory's Accelerator Technology Division are discussed, covering activities that occurred during the first six months of calendar 1982.