International Nuclear Information System (INIS)
Topics related to aerospace power are discussed, taking into account trends and issues of military space power systems technology, space station power system advanced development, the application and use of nuclear power for future spacecraft, the current status of advanced solar array technology development, the application of a parabolic trough concentrator to space station power needs, life test results of the Intelsat-V nickel-cadmium battery, and metal hydride hydrogen storage in nickel hydrogen batteries. Other subjects explored are concerned with alternative fuels, biomass energy, biomedical power, coal gasification, electric power cycles, and electric propulsion. Attention is given to an advanced terrestrial vehicle electric propulsion systems assessment, fuel cells as electric propulsion power plants, a sinewave ...
1985-08-18
US Air Force Aircraft in Southeast Asia Tested by the Air Force ...
... feet in length, and 26 feet 2 inches high. The AC-119G and AC-119K, are powered with two General Electric J85-17 jet engines pod-mounted ...
1970-03-01
The combined SOx/NOx/air toxics reduction process using activated coke and flue gas clean up
Energy Technology Data Exchange (ETDEWEB)
The dry desulfurization, denitrification and air toxics removal process using activated coke (AC) has been commercially adapted for flue gas clean up of a power plant, an oil refinery plant, an iron ore sintering plant, and a refuse incinerator. This process can achieve 100% removal of SO{sub x}, over 80% removal of NO{sub x} and effective removal of air toxics such as Hg, HCL, dioxines, etc., by contacting flue gas with AC and injecting NH{sub 3} for DeNO{sub x} at temperature range of about 100-200{degrees}C. For flue gas treatment, AC has several functions, which basically depends on the chemical surface group on AC inner surface. As adsorbent, AC can adsorb SO{sub x} at the relatively basic oxygen group site, where the adsorbed SO{sub x} is stored as sulfuric acid into micropore structure of AC. As catalyst, AC can ...
1996-10-01
Energy Technology Data Exchange (ETDEWEB)
The application of HVDC system to the trunk power supply system requires the transmission of DC power as much as possible to improve the stability of the whole AC/DC system. To meet this requirement, continued pulse system, which keeps sending a DC current even when an AC voltage lowers remarkably, has been used. The stability is much more improved by adding damping control which modulates converter active and/or reactive power. In order to make full use of such control effects, it is important that the HVDC system maintains stable operation during faults and reclosing of the AC system. In particular, it is necessary to prevent a repetitive commutation failure following the unbalanced AC transmission line faults. In this paper, the cause of the repetitive commutation failure is discussed by using the AC-DC ...
1992-01-20
PWM applications for the electric railway traction system fed by the AC/DC dual power line
Energy Technology Data Exchange (ETDEWEB)
The latest electronic circuit technology that can be used for the electric railway traction system fed by an AC/DC dual power line was developed. This system consists of reverse conducting GTO thyristors, microprocessors, and DSP`s. In the AC power supply line section, the line converter is controlled by PWM technology to secure a high power factor and reduce the higher harmonic generation of an input current as far as possible. The line converter and motor converter use reverse conducting GTO thyristors. Since these converters are cooled using a heat pipe cooler, they are reduced in size and weight. The electric grounding point of the main power circuit is set to the negative side of the DC line for AC and DC line sections. Therefore, the AC/DC selector switch was simplified in structure. Moreover, the DC input for the ...
1996-01-01
Electricity on the rig. Part 3 - New electric rig technology
Energy Technology Data Exchange (ETDEWEB)
The use of an SCR-controlled power system on an offshore drilling rig has lead to an increased acceptance of high technology equipment. Such equipment increases drilling productivity, reduces maintenance, and improves reliability. Most new rigs now have AC squirrel cage motors, brushless AC generators, silicon controlled rectifiers, DC motors, and swtichgear and motor starters. Several opportunities for cost reductions in SCR systems, such as improving the power factor, are studied in this paper.
1983-07-01
This project proposes to design and develop a new class of power converters (direct DC to AC) to drastically improve performance and optimize the cost, size, weight and volume of the DC to AC converter in SOFC systems. The proposed topologies employ a high frequency link; direct DC to AC conversion approach. The direct DC to AC conversion approach is more efficient and operates without an intermediate dc-link stage. The absence of the dc-link, results in the elimination of bulky, aluminum electrolytic capacitors, which in turn leads to a reduction in the cost, volume, size and weight of the power electronic converter. The feasibility of two direct DC to AC converter topologies and their suitability to meet SECA objectives will be investigated. Laboratory proto-type converters (3-5kW) will be designed and tested in Phase-1. A detailed design ...
2003-12-01
The hepatic-arterial/portal-venous scintiangiogram in alcoholic hepatitis
Energy Technology Data Exchange (ETDEWEB)
This study was designed to identify abnormalities in the hepatic-arterial/portal-venous scintiangiogram (SA) in alcoholic hepatitis (AH). SA's were performed in 35 patients with acute alcoholic hepatitis (AAH), 8; acute alcoholic hepatitis superimposed on cirrhosis (A/C), 14; and cirrhosis (C), 13. Posterior flows were done with a bolus of 10 mCi Tc-99m sulfur colloid with computer time-activity curves over the liver and left kidney. Curves were analyzed for per cent of hepatic arterial (HA) and portal venous contribution using the slope ratio method. Hepatic arterialization was estimated from the angle of the HA component of the curve. Reversal of the relative contribution of the hepatic and portal components of total flow were seen in all groups. Although quite severe in AH, the degree of reversal could not be used to differentiate among the groups. The average HA angle in AAH was 48.3 +- 8.1, in ...
1984-01-01
The hepatic-arterial/portal-venous scintiangiogram in alcoholic hepatitis
International Nuclear Information System (INIS)
This study was designed to identify abnormalities in the hepatic-arterial/portal-venous scintiangiogram (SA) in alcoholic hepatitis (AH). SA's were performed in 35 patients with acute alcoholic hepatitis (AAH), 8; acute alcoholic hepatitis superimposed on cirrhosis (A/C), 14; and cirrhosis (C), 13. Posterior flows were done with a bolus of 10 mCi Tc-99m sulfur colloid with computer time-activity curves over the liver and left kidney. Curves were analyzed for per cent of hepatic arterial (HA) and portal venous contribution using the slope ratio method. Hepatic arterialization was estimated from the angle of the HA component of the curve. Reversal of the relative contribution of the hepatic and portal components of total flow were seen in all groups. Although quite severe in AH, the degree of reversal could not be used to differentiate among the groups. The average HA angle in AAH was 48.3 +- 8.1, in A/C ...
1984-06-05
2000 MW HVDC link between England and France
Energy Technology Data Exchange (ETDEWEB)
The HVDC link across the English Channel, which was brought into service in 1986, has several innovative features. Techniques used in its construction together with recent developments have consolidated the viability of HVDC links for a variety of applications. Outlines the main features of the scheme, including the benefits of interconnecting the British and French 400 kV AC power systems; integration of the UK converter system to the 400 kV AC grid; the DC submarine cables; convertor equipment (particularly the UK installation); and future HVDC developments. 6 refs.
1987-03-01
Energy Technology Data Exchange (ETDEWEB)
Because of the chaotic nature of the corrosion process and the complexity of the electrochemical noise signals that are generated, there is no generally accepted method of measuring and interpreting these signals that allows the consistent detection and identification of sustained localized pitting (SLP) as compared to general corrosion. We have reexamined electrochemical noise analysis (ENA) of localized corrosion using different hardware, signal collection, and signal processing designs than those used in conventional ENA techniques. The new data acquisition system was designed to identify and monitor the progress of SLP by analyzing the power spectral density (PSD) of the trend of the corrosion current noise level (CNL) and potential noise level (PNL). Each CNL and PNL data point was calculated from the root-mean- square value of the ac components of current and potential fluctuation signals, which were measured simultaneously during a short ...
1999-01-13
Energy Technology Data Exchange (ETDEWEB)
In this report an isolated PWM DC-AC SICAM with an active capacitive voltage clamp is presented. AC-DC power supply is implemented in its simplest form: diode rectifier followed by a medium-size charge-storage capacitors and possibly with an EMC filter on the mains entrance. Isolation from the AC mains is achieved using a high frequency (HF) transformer, whose voltages are not audio-modulated. The latter simplifies the design and is expected to have many advantages over the approach where the transformer voltages are modulated in regards to the audio signal reference. Input stage is built as a DC-AC inverter (push-pull, half-bridge or a full-bridge) and operated with 50% duty cycle, with all the challenges to avoid transformer saturation and obtain symmetrical operation. On the secondary side the output section is implemented as rectifier+inverter AC-AC stage, ...
2004-03-15
AC motor drive system for electric cars
Energy Technology Data Exchange (ETDEWEB)
Various main circuit equipment with large capacity GTO thyristors are outlined for AC and DC electric cars. The configuration of a PWM converter system is presented for the AC main motor drive system of the Shinkansen trains, and its following features are described: the high power factor control capable of keeping a power factor 100% constantly, energy saving by power regenerative braking, the small triple structure with large capacity reverse-conducting GTO thyristors of 4,500V/3,000A, and the reduction of equivalent interfering current and harmonic current by three phase-triple phase difference operation. Furthermore, a control logic equipment with 16 bit MPU and a main transformer are outlined, and the verification test results of the control logic equipment by an analog model simulation and the combinational test results of the commercial equipment are reported. Prototype VVVF ...
1989-08-10
Research and development of photovoltaic power system; Taiyoko hatsuden system no jissho kenkyu
Energy Technology Data Exchange (ETDEWEB)
This paper reports the result obtained during fiscal 1994 on a demonstration research on photovoltaic power generating systems. Solar cells with an output of 750 kW, storage battery facilities with an output of 3,058 kWh, three DC-AC converters with a rating of 250 kW, and a diesel generator with an output of 300 kW having been installed up to the previous fiscal year were combined to perform comprehensive adjustments and tests such as battery charge/discharge tests and AC parallel operation tests. The battery charge/discharge tests revealed that the 10 hour rate discharge capacity meets the specifications, and the batteries are free of deterioration after a demonstration operation of about 4.5 months. Difference between the power generation record and the planned value is thought due to the following reasons: the array output data in a power line connected system come about 90% of ...
1994-12-01
Integral air-conditioning system for electric cars. Integrales Klimasystem fuer Elektroautomobile
Energy Technology Data Exchange (ETDEWEB)
Increasing environmental awareness and new legislation in Europe and, in particular, America have accelerated the development of marketable electric cars which satisfy customer demands in terms of performance, range capability, safety and comfort. Tomorrow's electric cars will therefore require powerful heating and cooling systems for the passenger compartment which meet the conditions specific to this particular mode of transport and which do not overly affect the range capability of such vehicles. At Behr GmbH suitable system concepts were developed at a very early stage which were based on a high proportion of recirculated air, the use of the A/C unit as a heat pump, and heat recovery. This paper will examine two typical A/C systems which combine good heating and cooling characteristics with the low electric power requirement of only 1,5-2 kW. (orig.).
1992-11-01
Direct energy recovery with ac electric power output
Energy Technology Data Exchange (ETDEWEB)
A concept of direct energy recovery system applying an alternating or rotating magnetic field is proposed for a negative-ion-based neutral beam injection system (NNB) to heat a plasma and/or drive a plasma current in a fusion reactor. Nearly same amounts of residual positive and negative hydrogen-isotope ion beams with beam energy of {approx}1 MeV are produced in an NNB using a gas neutralizing cell. Consequently, a recovered energy is obtained directly in the form of ac electric power, if these positive- and negative-ion beams are alternated or rotated and introduced to two or more recovery electrodes in turn by an alternating or rotating magnetic field. This concept will greatly reduce a technological difficulty in regeneration of a recovered electric energy with such a very high voltage. (author).
1994-12-31
Energy Technology Data Exchange (ETDEWEB)
Conventional methods for calculating electricity losses in pipe-type cable systems rely heavily on data measured in lower-voltage systems in the 1950s. With the new technique developed in this study, engineers can compute power losses more precisely for cables of various configurations and voltage ratings.
1985-04-01
Energy Technology Data Exchange (ETDEWEB)
This paper discusses, partially, the advantages and the disadvantages of the optimal power flow. It shows some of the difficulties of implementation and proposes solutions. An analysis is made comparing the power flow, BIGPOWER/CESP, and the optimal power flow, FPO/SEL, developed by the author, when applied to the CEPEL-ELETRONORTE and CESP systems. (author) 8 refs., 5 tabs.
1994-12-31
Database for thermal and mechanical properties of REBaCuO bulks
International Nuclear Information System (INIS)
The thermal properties (thermal conductivity, thermal diffusivity, thermoelectric power, thermal dilatation, etc.) and the mechanical properties (Young's modulus, strength, hardness, fracture toughness, etc.) have been measured at low temperatures (4-300K) and under a high magnetic field (0-10T) for about 50 REBaCuO bulks (RE=Y, Gd, Nd, Sm, Dy, etc.). We have constructed the database of these properties and opened it on the Web site (thermal properties: http://ikebehp.mat.iwate-u.ac.jp/database.html and mechanical properties: http://paris.mech.iwate-u.ac.jp/sc-bulk/database.html). The influence of the species of RE ions, the content, size and dispersion of the RE211 (or Nd422) phase and Ag particles and the defects distribution on these properties is characterized.
2005-10-01
Integrated Reconfigurable Intelligent Systems (IRIS) for ...
... They comprise of a power model for the representation of the electric system, a fluid model that represents the cooling fluid flow, three layers of ...
2009-10-31
International Nuclear Information System (INIS)
This paper describes the study of particles' dispersion in an isotropic turbulent flow. The particle's motion and the turbulent flow characteristics are calculated independently. While the particles' displacement is computed by the author's code, the flow is simulated with a commercial code : PowerFLOW. The particles and the flow are coupled through the relative velocity component of the aerodynamic force. When the simulated flow is turbulent, a turbulence regeneration model is used in order to get the flow instantaneous velocity. Validation of the method is done by comparing the particles' dispersion obtained with experimental results from literature and with the results calculated by FLUENT. Good accordance is found between numerical studies and experimental results. However, comparison between results of PowerFLOW ...
2004-05-09
Energy Technology Data Exchange (ETDEWEB)
The aim of this work is the study of the heat transfer and of thermal behaviour of the HF (high frequency) components (in fact capacitors) of the ITER-proto-2005-FCI antenna. Preliminary results carried out with the Castem software show that it is possible to cool the hottest part of the antenna efficiently. A water flow (1 bar, 25 Celsius degrees) or an helium flow (10 bars, 50 Celsius degrees) permit to limit the maximal value of the temperature to 270 Celsius degrees. A second software Ansys has allowed the author to simulate capacitors with more complicated shapes. (A.C.)
2003-07-01
Characterization of activated carbon prepared from chicken waste and coal
Energy Technology Data Exchange (ETDEWEB)
Activated carbons (ACs) were prepared from chicken waste (CW) and coal (E-coal) blended at the ratios of 100:0, 80:20, 50:50, 20:80, and 0:100. The process included carbonization in flowing gaseous nitrogen (300 mL min{sup -1}) at ca. 430{sup o}C for 60 min and successive steam activation (0.1 mL min{sup -1} water injection with a flow of N{sub 2} at 100 mL min{sup -1}) at 650{sup o}C for 30 min. Chicken waste is low in sulfur content but is high in volatile matter (about 55 wt %), and ACs with higher specific surface area were more successfully obtained by mixing with coal. The specific surface area of the CW/Coal blend AC can be estimated by SSA{sub BET} = -65.8x{sup 2} + 158x + 168, where SSA{sub BET} is the specific surface area in m{sup 2} g{sup -1} as determined by the BET method using CO{sub 2} as the adsorbent, where x is the coal fraction by weight in the CW/coal blend ...
2007-12-15
An improved soft switched PWM interleaved boost AC-DC converter
International Nuclear Information System (INIS)
In this paper, an improved soft switched two cell interleaved boost AC/DC converter with high power factor is proposed and investigated. A new auxiliary circuit is designed and added to two cell interleaved boost converter to reduce the switching losses. The proposed auxiliary circuit is implemented using only one auxiliary switch and a minimum number of passive components without an important increase in the cost and complexity of the converter. The main advantage of this auxiliary circuit is that it not only provides zero-voltage-transition (ZVT) for the main switches but also provides soft switching for the auxiliary switch and diodes. Though all semiconductor devices operate under soft switching, they do not have any additional voltage and current stresses. The proposed converter operates successfully in soft switching operation mode for a wide range of input voltage level and the load. In addition, it has advantages such as fewer structure ...
2011-01-01
Power control for wind turbines in weak grids: Concepts development
Energy Technology Data Exchange (ETDEWEB)
Presently, high wind potentials in remote areas may not be utilized for electricity production due to limited grid transmission capacity and/or difficulties in matching the electricity production with the demand. The overall project objective is to help overcome these bottlenecks, i.e. to identify and analyze methods and technologies for making it viable to utilize more of the wind potential in remote areas. The suggestion is to develop a power control concept for wind turbines which will even out the power fluctuations and make it possible to increase the wind energy penetration. The main options are to combine wind power with a pumped hydro power storage or with an AC/DC converter and battery storage. The AC/DC converter can either be an `add-on` type or it can be designed as an integrated part of a variable speed wind turbine. The idea is that combining wind ...
1999-03-01
Studies on a new kind of fuzzy power system stabilizer
Energy Technology Data Exchange (ETDEWEB)
This paper is concerned with the application of a new fuzzy inference method to the design of fuzzy power system stabilizer. Based on Truth-Value-Flow-Inference (TVFI), a fuzzy logic controlled power system stabilizer is proposed to enhance the stability of power system with weak or negative damping. The design of the proposed fuzzy power system stabilizer is presented. Numerical simulation results are presented and compared with two other kinds of fuzzy power system stabilizers. (author)
1998-12-31
A study on the anodic protection of titanium evaporators in Al[sub 2](SO[sub 4])[sub 3] solution
Energy Technology Data Exchange (ETDEWEB)
The feasibility of the anodic protection of titanium evaporators in Al[sub 2](SO[sub 4])[sub 3] solution was studied by the measurement of polarization curves, weight loss, solubility of passive film and AC impedance. The protection parameters and efficiency were determined. In addition, the practical technology of anodic protection was studied by screening reference electrodes and auxiliary cathodes. Throwing power was also measured. Four rows of tube-type evaporators of titanium have been anodically protected in situ. Field tests lasting more than one year shows satisfactory results. (orig.)
1993-07-01
[Pilot-plant testing for flue gas desulfurization and dust removal by activated coke].
A developed flue gas desulfurization and dust removal process with a cross-flow moving bed filled with activated coke (AC) was tested on a pilot scale with the gas treatment capacity of 1000 mg x h(-t). The results show that a easy-operating and stable-running pilot-scale testing equipment can be reached, and under the conditions of testing space velocity, the feed gas temperature of 120 degrees C, SO2 concentrations of 3232-6006 mg x m(-3) and dust concentration of 89.3-1599.7 mg x m(-3), the high efficiency of flue gas desulfurization and dust removal is reached with the purity of dust less than 50 mg x m(-3). In the technology, the spent AC was regenerated by heating, and the SO2 concentration in the desorption gas is about 40.1%, which can be efficiently recovered as a sulfur resource. Favorable economy benefit can be reached by using the process. PMID:16850821
2006-05-01
Implications of high temperature superconductors for power generation
International Nuclear Information System (INIS)
Superconducting generators for high power applications have been of interest for a number of years. Superconducting generators using low temperature superconductors (LTS) have been manufactured to produce up to 20 MW of electrical power and have been configured in either synchronous alternators which have an AC output that may be subsequently rectified to produce DC and homopolar generators which produce low voltage DC. Typically these generators require scrupulous attention to vacuum integrity for cryogenic insulation at 4.2K and tend to be somewhat fragile because of extensive thermal and magnetic shields that are not required in conventional power generators. Recently, high purity aluminum composites have been developed for a high power AC generator that is cooled by cryogenic hydrogen at 21K. This aluminum generator is very compact and lightweight and is ...
1991-08-03
An Experimental study on a Method of Computing Minimum flow rate
International Nuclear Information System (INIS)
Many pump reliability problems in the Nuclear Power Plants (NPPs) are being attributed to the operation of the pump at flow rates well below its best efficiency point(BEP). Generally, the manufacturer and the user try to avert such problems by specifying a minimum flow, below which the pump should not be operated. Pump minimum flow usually involves two considerations. The first consideration is normally termed the 'thermal minimum flow', which is that flow required to prevent the fluid inside the pump from reaching saturation conditions. The other consideration is often referred to as 'mechanical minimum flow', which is that flow required to prevent mechanical damage. However, the criteria for specifying such a minimum flow are not clearly understood by all parties concerned. Also various factor and ...
2009-10-01
Optimal security-constrained power scheduling by Benders decomposition
Energy Technology Data Exchange (ETDEWEB)
This paper presents a Benders decomposition approach to determine the optimal day-ahead power scheduling in a pool-organized power system, taking into account dispatch, network and security constraints. The study model considers the daily market and the technical constraints resolution as two different and consecutive processes. The daily market is solved in a first stage subject to economical criteria exclusively and then, the constraints solution algorithm is applied to this initial dispatch through the redispatching method. The Benders partitioning algorithm is applied to this constraints solution process to obtain an optimal secure power scheduling. The constraints solution includes a full AC network and security model to incorporate voltages magnitudes as they are a critical factor in some real power systems. The algorithm determines the active power ...
2007-05-15
A New Green Power Inverter for Fuel Cells
DEFF Research Database (Denmark)
This paper presents a new grid connected inverter for fuel cells. It consists of a two stage power conversion topology. Since the fuel cell operates with a low voltage in a wide voltage range (25 V-45 V) this volt- age must be transformed to around 350-400 V in order to invert this dc power into ac power to the grid. The proposed converter consists of an isolated dc-dc converter cascaded with a single phase H-bridge inverter. The dc-dc converter is a current-fed push-pull converter. A new dedicated voltage mode startup procedure has been developed in order to limit the inrush current during startup. The inverter is controlled as a power factor controller with resistor emulation.Experimental results of converter efficiency, grid performance and fuel cell response are shown for a 1 kW prototype. The proposed converter exhibits a high efficiency in a wide power ...
2002-01-01
Physical modeling of flow control device test in intake structure
International Nuclear Information System (INIS)
The seawater in the intake structure flows into the large pump to with draw excess heat from the turbine steam condenser. In the intake structure of a nuclear power plant, undesirable pump operating characteristics such as vortices, impeller damages and non-uniform pump-approach flow around the pump bells take place frequently due to poorly-arranged intake geometry. In this study, physical modeling test was performed to predict the hydraulic phenomenon, and proposed flow control devices.
2000-05-01
Session 1: Geothermal Pumping Systems and Two-Phase Flow Studies
Energy Technology Data Exchange (ETDEWEB)
Improvements in electric submersible pumping systems have resulted in a demonstrated downhole running life of one year for low horsepower units operating in 180 C brine. The implementation of a prototype pressurized lubrication system to prevent brine intrusion and loss of lubricating oil from the motor and protector sections has been successfully tested. Second generation pressurized lubrication systems have been designed and fabricated and will be utilized in downhole production pumping tests during FY84. Pumping system lifetime is currently limited by available power cable designs that are degraded by high-temperature brine. A prototype metal-sheathed power cable has been designed and fabricated and is currently undergoing destructive and nondestructive laboratory testing. This cable design has the potential for eliminating brine intrusion into the power delivery system through the use of a hermatically sealed cable from ...
1983-12-01
Measurements of plasma density profiles driven by p-polarized microwaves
Energy Technology Data Exchange (ETDEWEB)
For supersonic plasma flow velocities, instead of the usual shelf-step profile seen for subsonic flow, an overdense bump and cavity is observed. The profile is stable for long times even for moderate power microwaves.
1983-07-11
Energy Technology Data Exchange (ETDEWEB)
Using electromatic field theory, a new method is developed for calculating alternating current in power cables installed in pipes of carbon steel (magnetic pipes). The technique for evaluating these losses is based on the method of images which replaces complicated distribution of currents in the system with a sequence of thin conductors. The method not only gives a mathematical framework for the solution of alternating current losses, but it also gives the underlying physical picture of effects contributing to these losses. Skin effect, proximity effect and losses due to the pipe are calculated separately. For the first time, the increase of losses in the conductors, when the cables are placed in a magetic pipe, are analyzed mathematically. Good agreement is obtained between the result of calculations and the experimentally determined ac-dc resistance ratios for pipe-type cables with concentric stranded copper conductors and also for cables ...
1985-04-01
Energy Technology Data Exchange (ETDEWEB)
Boiling jet impingement cooling is currently being explored to cool power electronics components. In hybrid vehicles, inverters are used for DC-AC conversion. These inverters involve a number of insulated-gate bipolar transistors (IGBTs), which are used as on/off switches. The heat dissipated in these transistors can result in heat fluxes of up to 200 W/cm{sup 2}, which makes the thermal management problem quite important. In this paper, turbulent jet impingement involving nucleate boiling is explored numerically. The framework for these computations is the CFD code FLUENT. For nucleate boiling, the Eulerian multiphase model is used. The numerical results for boiling water and R113 jets (submerged) are validated against existing experimental data in the literature. Some representative IGBT package simulations that use R134a as the cooling fluid are also presented. (author)
2008-01-15
Delta connected resonant snubber circuit
Energy Technology Data Exchange (ETDEWEB)
A delta connected, resonant snubber-based, soft switching, inverter circuit achieves lossless switching during dc-to-ac power conversion and power conditioning with minimum component count and size. Current is supplied to the resonant snubber branches solely by the dc supply voltage through the main inverter switches and the auxiliary switches. Component count and size are reduced by use of a single semiconductor switch in the resonant snubber branches. Component count is also reduced by maximizing the use of stray capacitances of the main switches as parallel resonant capacitors. Resonance charging and discharging of the parallel capacitances allows lossless, zero voltage switching. In one embodiment, circuit component size and count are minimized while achieving lossless, zero voltage switching within a three-phase inverter.
1998-01-01
International Nuclear Information System (INIS)
Manitoba Hydro's Ice Storm Management Program to reduce ice damage to overhead power lines in the voltage range of 8 kV to 115 kV is described. Overhead power lines are de-iced either by AC ice melting, which involves placing a three-phase short at a calculated point, or ice rolling, which is a process of mechanically stripping ice from conductors. Direct current heating and underground distribution systems are also accepted prevention measures. Advantages and disadvantages of each of these methods of de-icing are reviewed. Material for this paper has been extracted from a workshop manual prepared for the 1993 and 1998 Ice Storm Management workshops organized by Manitoba Hydro through the Canadian Electrical Association. 1 ref.
1999-03-29
Dependence of thermal plasma jet temperature on discharge power and gas flow rate
International Nuclear Information System (INIS)
With the help of heat balance equation and high temperature thermodynamic function, the calibration relation of jet temperature with discharge power, gas flow rate was obtained for nitrogen thermal plasma. It was shown that the results were agreed with the principle of similarity. The jet temperature was a function of Peff/f, instead of a general two variables function of Peff and f, which were effective discharge power and working gas flow rate, respectively. A related discussion has been given; it will be referable to thermal plasma applications. (authors)
2008-03-01
on practical projects such as woodland management, limestone grassland management, cattle management, conflict management and education. ...Cathy Heaton Telephone 01772 892400 Email cenquiries@uclan.ac.uk www.uclan.ac.uk/schoolbne
International Nuclear Information System (INIS)
In the heat exchangers of power plants, scale deposition may occur, especially at the leading edge of contraction. The growth of scale can lead to an increase in pressure and cause oscillation of the water level. In our previous study, the dependence of flow on contraction geometry was analyzed numerically and empirically. It was shown that the contraction ratio of hydraulic diameter of the flow path contributed greatly to the difference in pressure drop and turbulent kinetic energy at the leading edge of the flow path. In this study, the effect of contraction geometry and flow rate on scale adhesion was studied in AVT chemistry at 270degC using a high-velocity scale-adhesion test loop. The differential pressure and the amount of scale deposited due to scale adhesion at the leading edge of the flow path increased more in a quatrefoil-type ...
1999-05-01
Device for controlling feedwater at low power of nuclear power plants
International Nuclear Information System (INIS)
Purpose: To provide a feedwater control device capable of minimizing the adverse response of steam drum level at low power. Consitution: In order to perform feedwater control at low power by the substantial control of three factors, that is, main steam flow rate, feedwater flow rate and steam drum level, the main steam flow rate is determined from the reactor output and feedwater rate is determined from the changes in the feedwater temperature due to the mixing of waters in the reactor clean up system and feedwater. If a difference is resulted between these flow rates, a starting feedwater regulator is controlled instantly to eliminate the difference. The water level in the steam drum is used for amending the difference from the final set value of the drum water level, by which the adverse response of the steam drum level can be minimized. (Seki, T.).
Energy Technology Data Exchange (ETDEWEB)
ITN Energy Systems is developing next-generation solar cells based on the concepts of an optical rectenna. ITN's optical rectenna consists of two key elements: (1) an optical antenna to efficiently absorb the incident solar radiation, and (2) a high-frequency metal-insulator-metal (MIM) tunneling diode that rectifies the AC field across the antenna, providing DC power to an external load. The combination of a rectifying diode at the feedpoints of a receiving antenna is often referred to as a rectenna. Rectennas were originally proposed in the 1960s for power transmission by radio waves for remote powering of aircraft for surveillance or communications platforms. Conversion efficiencies greater than 85% have been demonstrated at radio frequencies (efficiency defined as DC power generated divided by RF power incident on the device). Later, concepts were ...
2003-02-01
Beam direct converter with varying magnetic field
Energy Technology Data Exchange (ETDEWEB)
The concept of a direct energy recovery system that applies a varying magnetic field is proposed for a negative-ion-based neutral beam injection system (NNB) to heat a plasma and/or drive a plasma current in a fusion reactor. The output beam energy and power of such an NNB will be {approximately}1 MeV and {approximately}1- MW/beam-line, respectively, and nearly the same amounts of positive- and negative-ion beams remain unneutralized in an NNB by using a gas-neutralizing cell. Therefore, the output of a beam direct convertor in an NNB is a bipolar direct current (dc) electric power with close to {plus_minus} 1 MV and several amperes if a conventional electrostatic or magnetostatic field is applied for ion beam separation. However, such high-voltage dc power is difficult to handle at the point of the regeneration of the power back to a commercial electric line because a very high voltage inverter tough ...
1994-12-01
Verification of coolant flow distribution in 540 MWe Indian PHWR during commissioning
International Nuclear Information System (INIS)
The pressurized Heavy Water Reactor (PHWR) consists of horizontal calandria vessel containing a large number of pressure tubes (fuel channels) connected to the reactor inlet and outlet headers by individual feeders. Coolant flow distribution among the pressure tubes play a vital role in extraction of thermal power. For these reactors one of the design objectives is to achieve uniform coolant outlet temperatures by providing coolant flows according to the channel power. This is achieved by the design process known as feeder sizing. This basically consists of accounting for the individual channel power and centre line geometry of individual feeder and iteratively adjusting the feeder hydraulic resistances within the design constraints such as limiting flow velocities, channel flows. Recently, the first unit of 540 MWe i.e Tarapur Atomic ...
2006-11-13
Recycling flow control device for a nuclear reactor
International Nuclear Information System (INIS)
Object: To permit a valve operation test to be periodically made during plant operation without causing variations in plant power by detecting flow control valve defect on the basis of a valve aperture alteration instruction. Structure: Step signals which are equal in absolute value and opposite in sign are coupled to the input side of flow controllers provided on the recycling loops of two or more recycling flow control systems. With these inputs the aperture of the flow control valve on one side is increased (or reduced) while the aperture of the valve on the other side is reduced (or increased). As a result, the recycling flow rate in the loop on one side is increased (or reduced) while that on the other side is reduced (or increased). Whether the valve is normally operating or not is confirmed by checking the recycling flow rate and ...
Energy Technology Data Exchange (ETDEWEB)
In this work, the right management procedure for hydraulic power oil will be discussed and suggested. A thermal power plant turbine should respond to the change of load status. However, to satisfy the frequency of alternating current, the revolution per minute should be kept constant. Therefore, by controlling the flow rate of the steam to the turbine, the governor satisfies the load variation without alternating the revolution per minutes of the turbine. To protect the governor, the hydraulic power unit should be managed carefully by controlling the quality and the flow rate of the oil.
2008-07-01
Use of a static frequency converter for rapid load response in pumped-storage plants
Energy Technology Data Exchange (ETDEWEB)
Most pumped-storage plants have the capability to operate as synchronous condensers. As such, they can be brought on line very quickly to support system load requirements. However, one of the effects of making a rapid transition from synchronous condenser operation to turbine/governor operation is an initial reverse power flow into the machine. This reverse power flow can be very undesirable at a time when the system is calling for load support. On weak or isolated systems, this reverse power flow can lead to objectionable voltage and frequency dips in the system. With the proper utilization of a static frequency converter (SFC) and its associated controls and auxiliary switchgear systems, the reverse power flow resulting from a transition from synchronous condenser operation can be eliminated. This paper will describe ...
1995-12-01
Electron flow in the SABRE linear induction adder in positive polarity
International Nuclear Information System (INIS)
In a positive polarity induction adder each of the induction cavities is a cathode, which emits electrons at a unique potential. These broad spectrum electrons strongly affect Magnetically Insulated Transmission Line (MITL) behavior. Electron flow decreases the cavity-to-MITL coupling efficiency, and reduces the power transport efficiency along the system. Also, the operating impedance of the MITL is lowered, reducing the diode impedance required for good coupling and good total system power efficiency. It is therefore imperative to understand the details of MITL electron flow. In previous work, measurement of MITL electron flow for a twenty-stage linear induction adder (Hermes III), operated in positive polarity, was compared with simulations. There was qualitative agreement, but some differences were noted. For example, measured electron flow in the first ...
1993-05-17
Industrial experience with an intelligent AC/DC standard
Energy Technology Data Exchange (ETDEWEB)
AC/DC voltage standards based entirely on solid-state references used as secondary, working, or transfer standards is widespread, although metrological performance is typically defined only via comparison with a higher level standard. The present report shows the improvements of the output metrological characteristics of an ac/dc calibrator by establishing three internal hierarchical levels of dc voltage references and by constant calibration of ac measuring circuits.
1989-04-01
The role of natural circulation in the FFTF [Fast Flux Test Facility] passive safety tests
International Nuclear Information System (INIS)
A series of tests were completed at the Fast Flux Test Facility to demonstrate the passive safety characteristics of liquid metal reactors with natural circulation flow. The first test consisted of transition from forced to natural circulation flow at an initial decay power of 0.3%. The second test represented an unprotected loss-of-flow transient to natural circulation from 50% power with the control rods prevented from scramming into the core. The third test was a steady-state, natural circulation condition with core fission powers up ato about 2.3%. Core sodium data and results of single and multi-channel computer models confirmed the reliability and effectiveness of natural circulation flow for liquid metal reactor safety.
1987-12-13
Space effect on liquid film flow in a BWR fuel bundle
Critical power at boiling transition is an important factor in a boiling water reactor (BWR) fuel bundle design. Boiling transition under high quality accounts for dryout as the result of the complete disappearance of film flow on a fuel rod. This liquid film vanishing process can be calculated by the liquid film model, which takes into account the evaporation due to heat from the rod surface, liquid film entrainment by steam flow, and liquid droplet deposition. It is known that spacers affect liquid film entrainment and liquid droplet deposition, so the detailed study of spacer effects on hydrodynamic characteristics is necessary for critical power prediction based on the film flow model. Many studies have been conducted to examine spacer effects on liquid film flow. However, most of them are restricted to simple test sections such as a rectangular conduit. ...
1991-01-01
On load flow control in electric power systems
Energy Technology Data Exchange (ETDEWEB)
This dissertation deals with the control of active power flow, or load flow in electric power systems. During the last few years, interest in the possibilities to control the active power flows in transmission systems has increased significantly. There is a number of reasons for this, coming both from the application side - that is, from power system operations - and from the technological side. where advances in power electronics and related technologies have made new system components available. Load flow control is by nature a multi-input multi-output problem, since any change of load flow in one line will be complemented by changes in other lines. Strong cross-coupling between controllable components is to be expected, and the possibility of adverse interactions between these ...
2000-01-01
Fundamental limits on beam stability at the advanced photon source
International Nuclear Information System (INIS)
Orbit correction is now routinely performed at the few-micron level in the Advanced Photon Source (APS) storage ring. Three diagnostics are presently in use to measure and control both AC and DC orbit motions: broad-band turn-by-turn rf beam position monitors (BPMs), narrow-band switched heterodyne receivers, and photoemission-style x-ray beam position monitors. Each type of diagnostic has its own set of systematic error effects that place limits on the ultimate pointing stability of x-ray beams supplied to users at the APS. Limiting sources of beam motion at present are magnet power supply noise, girder vibration, and thermal timescale vacuum chamber and girder motion. This paper will investigate the present limitations on orbit correction, and will delve into the upgrades necessary to achieve true sub-micron beam stability.
1998-12-10
Development of ambient sampling chemi/chemical ion source with dielectric barrier discharge
British Library Electronic Table of Contents (United Kingdom)
The development of a new configuration of chemical ionization (CI)-based ion source is presented. The ambient air containing the gaseous sample is sniffed into an enclosed ionization chamber which is of sub-ambient pressure, and is subsequently mixed with metastable species in front of the ion inlet of the mass spectrometer. Metastable helium atoms (He*) are used in this study as the primary ionizing agents and are generated from a dielectric barrier discharge (DBD) source. The DBD is powered by an AC high-voltage supply and the configuration of the electrodes is in such a way that the generated plasma is confined within the discharge tube and is not extended into the ionization chamber. The construction of the ion source is simple, and volatile compounds released from the bulky sample can...
2010-01-01
Breathers in Josephson junction ladders: Resonances and electromagnetic wave spectroscopy
DEFF Research Database (Denmark)
We present a theoretical study of the resonant interaction between dynamical localized states (discrete breathers) and linear electromagnetic excitations (EE's) in Josephson junction ladders. By making use of direct numerical simulations we find that such an interaction manifests itself by resonant steps and various sharp switchings (voltage jumps) in the current-voltage characteristics. Moreover, the power of ac oscillations away from the breather center (the breather tail) displays singularities as the externally applied dc bias decreases. All these features may be mapped to the spectrum of EE's that has been derived analytically and numerically. Using an improved analysis of the breather tail, a spectroscopy of the EE's is developed, The nature of breather instability driven by localized EE's is established.
2001-01-01
Energy Technology Data Exchange (ETDEWEB)
As part of the EPRI Motor-Operated Valve (MOV) Performance Prediction Methodology, a System Flow Model (SFM) has been developed to determine the differential pressure (DP) across MOVs as they are stroked in typical power plant systems. Input to the SFM includes valve flow characteristics (such as flow coefficient) and system characteristics (such as pump head/flow curve). The primary output is differential pressure across the valve at each stroke position. The SFM was validated by comparison with test data from the EPRI Flow Loop Test Program. In this study, we calculated DP using SFM and performed DP test for four MOVs. Compared between calculated DP and test DP of four MOV, respectively good agreements are found. (author). 6 refs., 9 figs., 1 tab.
1999-11-01
Transient Critical Heat Flux tests on a rod bundle simulating Pressurized Water Reactors
International Nuclear Information System (INIS)
Transients induced in nuclear power plants from many sources result in one or more fluid conditions changing with time. Fluid conditions of pressure, inlet temperature, inlet flow, or even system power many change separately or in conjunction with each other. The result of the condition change may be one which induces departure from nucleate boiling. An experimental investigation of transient which were intended to achieve Critical Heat Flux was performed at the Heat Transfer Research Facility of Columbia University for Siemens Nuclear Power Corporation. The transients were set up to include broad ranges of flow and pressure conditions near the operating range of pressurized water reactors. Transient events were dominated by varying single conditions and measuring the response of the system and of the rod thermocouples. Because of coupling effects within the test loop, secondary ...
International Nuclear Information System (INIS)
Development of the Conawapa-Winnipeg power transmission complex in Manitoba includes five interrelated transmission and conversion facilities. Environmental and socio-economic assessment work done to date on one component of this system (the upgrading of the Southern Receiver System) is described. This system is composed of a network of high voltage transmission lines and station facilities serving power demand in Winnipeg and southern Manitoba. The upgrading involves three main elements: energizing a second 230 kV ac circuit on an existing tower line running from the proposed Riel Station site to the existing St. Vital Station; constructing a new double-circuit 230 kV tower line on the same existing right-of-way between St. Vital and the Riel site area; and installing an additional transformer and other necessary equipment at St. Vital and other stations affected by the upgrade. The environmental impacts of these projects ...
1992-01-01
Energy Technology Data Exchange (ETDEWEB)
This symposium about electric operational and expansion planning presents several articles that approaches issues such as, monitoring the power system stability, electrical load modelling, reliability in power systems, optimization in power systems, integrated resources planning in power systems, reactive control through static compensators, power flow analysis, system modelling, etc
1994-12-31
Estimation of CHF ratio at various power levels in TAPP-3 and 4 reactors
International Nuclear Information System (INIS)
TAPP-3 and 4 are the 540 MWe PHWRs having horizontal fuel channel. At normal 100% FP operation there is no boiling in the channel. However, when the power increases due to any transient, the boiling may start in the channel. The main application for critical heat flux (CHP) prediction is to set the operating power with a comfortable margin to avoid CHF occurrence. This margin of CHF can be expressed in terms of minimum critical heat flux ratio (MCHFR), which is the ratio of CHF to local heat flux for the same pressure, mass flux and quality. The CHF depends on power, coolant flow rate as well as coolant condition in the channel. As the power increases the flow reduces in the channel and cooling is degraded. The thermal hydraulic code is developed for present analysis. The output of analysis are CHF prediction quality calculation at axial locations of the maximum ...
2005-12-01
Energy Technology Data Exchange (ETDEWEB)
The Feedwater System supplies feedwater to the steam generator at the required pressure, temperature and flow rate during the plant start-up, normal power operation, shutdown. When the Feedwater System is inoperable or unavailable, the Auxiliary Feedwater System supplies emergency feedwater to the steam generator. If main steam line break occurs, the increase of feedwater flow rate of the faulted steam generator due to decrease of the pressure in the faulted steam generator results in adverse effects in aspect of overcooling the Reactor Coolant System and increased containment pressure/temperature. To optimize the containment mass/energy analysis, this paper evaluates the maximum feedwater and auxiliary feedwater flow rate delivered to the faulted steam generator at each stage of pressure decrease in the faulted steam generator after a main steam line break accident. Calculated Feedwater ...
2001-05-01
Energy Technology Data Exchange (ETDEWEB)
Statoil is operating an increasing number of offshore and onshore pipelines in the North Sea area and elsewhere. Cathodic protection is a significant part of the corrosion management for these lines and we have collected a significant amount of experience with respect to design and operation of the systems. This paper deals with our comprehensive program for the onshore cathodic protection systems and the various challenges in different countries with respect to technical matters, such as operating conditions and different terrain. Generally, the systems are based on automatically controlled rectifier systems with a wide range of current drainage and very comprehensive monitoring of potentials and current flowing. The use of coupons, polarisation cells and buried reference cells are essential, as well as the use of intensive measurements along the route. The use of online monitoring of selected test posts and all rectifier units is considered essential for remote ...
1999-07-01
Energy Technology Data Exchange (ETDEWEB)
Large capacity adjustable speed machines (ASMs) at pumped storage power station have been put into full operation and the operating characteristics of ASM have been highly evaluated from the view point of power system operation. The output power (input power) of ASM can be controlled very quickly by applying a vector control scheme to the excitation control. This quick responsive feature of ASM can make it possible to improve the stability of the neighbor sub-power system. For improvement of transient stability, the output power of ASM is reduced very quickly in order to control the acceleration of neighbor generators during and after transmission line faults. For improvement of dynamic stability, the output power of ASM is modulated in accordance with the stabilizing signals detected from the swing of generator rotor or the ...
1997-01-20
International Nuclear Information System (INIS)
Papers are presented on space power requirements and issues, space photovoltaic systems, space solar dynamic systems, space thermal systems, manned and unmanned space power systems, thermionics, and thermoelectrics. Also considered are high power devices for space power systems, high power conversion for space power systems, 1-10 kWe nuclear space power sources, 100-kW class nuclear power concepts, space reactor safety, and multimegawatt space nuclear power systems. Other topics include space power systems automation, space kilovolt technology, space power electronics, space lithium and nickel-cadmium batteries, lithium sodium storage, and space fuel cells. Papers are also presented on space nickel hydrogen batteries, alternative energy concepts and fuels, ...
1987-08-10
Evaluation of validity of the RELAP5/MOD3 flow regime map for horizontal tubes
Energy Technology Data Exchange (ETDEWEB)
RELAP5/MOD3 code was developed for western type power water reactors with vertical steam generators. Thus, this code should be validated also for VVER design with horizontal steam generators. The validation work, which has been started in Lappeenranta University of Technology (LUT), has already shown some weaknesses of the code. For example the flow inside a steam generator horizontal tube in some accident cases is not correctly modelled by the code. It may be the result of erroneous prediction of the flow regime. The aim of the study is the attempt of verification of the flow regime map, which is used in the RELAP5/MOD3 computer code for two-phase flow in horizontal tubes. (18 refs.).
1996-12-31
Energy Technology Data Exchange (ETDEWEB)
Various measurement tools that are used in chaos theory were applied to analyze two-phase pressure signals with the objective of identifying and interpreting flow pattern transitions for two-phase flows in a small, horizontal rectangular channel. These measurement tools included power spectral density function, autocorrelation function, pseudo-phase-plane trajectory, Lyapunov exponent,s and fractal dimensions. It was demonstrated that the randomlike pressure fluctuations characteristic of two-phase flow in small rectangular channels are chaotic, and governed by a high-order deterministic system. The correlation dimension is potentially a new approach for identifying certain two-phase flow patterns and transitions.
1996-06-01
Energy Technology Data Exchange (ETDEWEB)
A one-way coupling system between the plant simulator TRAC/BF1-ENTREE and the subchannel code with the improved cross flow model, NASCA, has been developed. Based on a scenario of turbine trip tests in the Peach Bottom Unit 2, the wide and rapid reactivity insertion transient induced by the system pressure rise was calculated. The pin power distribution in hot bundles was re-constructed considering heterogeneity of the fuel bundle. When the neighboring control blade is withdrawn, NASCA predicted that the steady-state bundle exit void distribution was nearly flat with regardless of the pin power distribution. However, void distributions in the middle and lower bundle regions became complicated depending on the pin power and the two-phase flow regime in each subchannel. The pin power distribution rapidly changed according to traveling of control blades. However, ...
2002-11-01
News from the world; Echos du monde
Energy Technology Data Exchange (ETDEWEB)
This document gathers a series of very short articles concerning nuclear industry around the world. Areva company is investing 30 million euros in its Chalon-Saint-Marcel plant, it is the consequence of the extension of service life of nuclear power plants in the Usa. Areva holds 40% of the American market concerning the replacement of steam generators and 50% of that concerning the replacement of closure heads. The Obrigheim nuclear power plant was definitely closed down on may 2004, this decommissioning is a step forward in the German policy of progressively stepping out of nuclear energy. Chinese authorities are willing to construct 40 nuclear reactors in 15 years, despite that, the contribution of nuclear energy to the generation of electricity will reach only 4% in 2020. In 2007 Cea will begin the construction works of a new research reactor (Jules Horowitz reactor) in the Cadarache site. Prices of the yellow cake have been going up during ...
2005-04-01
Energy Technology Data Exchange (ETDEWEB)
A highly efficiency partial smoothing method is proposed to be used for inverters for 40W class household fluorescent inverters. In this system, the input current from the commercial AC power source is accumulated in a capacitor with comparatively small capacity as the electric charge, and then the lamp circuit is driven by the inverter utilizing the charging voltage of the capacitor and the charging voltage of the separately prepared partial smoothing capacitor. By this method, the RF harmonic components in the supply current can be decreased to improve the power factor with no complicated feedback controlling device. In addition, comparatively small capacity coils and capacitors can be used. The structure of the circuit and the operation of this proposed method are described, and the operational characteristic of the prototype circuit and the result of analysis are shown. Furthermore, problems and improving method of the ...
1997-06-20
Direct energy conversion for IEC fusion for space applications
Energy Technology Data Exchange (ETDEWEB)
The paper describes a concept of extracting fusion power from D-{sup 3}He fueled IEC (Inertia Electrostatic Configuration) devices. The fusion system consists of a series of fusion modules and direct energy converters at an end or at both ends. This system of multiple units is linear and is connected by a magnetic field. A pair of coils anti-parallel to the magnetic field yields a field-null domain at the center of each unit as required for IEC operation. A stabilizing coil installed between the coil pairs eliminates the strong attractive force between the anti-parallel coils. Accessible regions for charged particle trajectories are essentially isolated from the coil structure. Thus, charged particles are directed along magnetic field lines to the direct energy converter without appreciable losses. A direct energy converter unit designed to be compatible to this unique system is also described. It basically consists of a separator and a traveling wave converter. A ...
2000-08-01
Energy Technology Data Exchange (ETDEWEB)
The object of this research is the evaluation of the performance of ultra high speed relays (UHSR's) used for protection of a-c transmission lines. For purposes of this report, these are relays whose response time is less than a quarter of a cycle of the 60 Hz wave (i.e. 4.167 ms.). To identify relaying schemes that may comply with this definition, a literature survey was undertaken. The selected relays were studied in detail and modeled on a digital computer. A theoretical description of these relays is presented. Records of real transient data as well as of simulated data were used as input to the digital models of relays. The real data were recorded by means of monitoring stations connected to the Florida Power and Light Company transmission lines. The simulated data were obtained by modeling the relevant parts of the utility's transmission system using a University of British Columbia simplified version of the well known ...
1984-01-01
on practical projects such as woodland management, limestone grassland management, cattle management, conflict management and education. ...Cathy Heaton Telephone 01772 892400 Email cenquiries@uclan.ac.uk www.uclan.ac.uk/schoolbne
Application of hydraulic network analysis to motor operated butterfly valves in nuclear power plants
International Nuclear Information System (INIS)
This paper presents the application of hydraulic network analysis to evaluate the performance of butterfly valves in nuclear power plant applications. Required actuation torque for butterfly valves in high-flow applications is often dictated by peak dynamic torque. The peak dynamic torque, which occurs at some intermediate disc position, requires accurate evaluation of valve flow rate and pressure drop throughout the valve stroke. Valve flow rate and pressure drop are significantly affected by the valve flow characteristics and the hydraulic system characteristics, such as pumping capability, piping resistances, single and parallel flow paths, system hydrostatic pressure, and the location of the motor-operated valve (MOV) within the system. A hydraulic network analysis methodology that addresses the effect of these parameters on the MOV performance is presented. ...
1992-07-01
Metrology measurement capabilities
Energy Technology Data Exchange (ETDEWEB)
Since 1958, the AlliedSignal Federal Manufacturing and Technologies (FM and T) Metrology Department has developed measurement technology and calibration capability in four major areas of measurement: mechanical; environmental, gas, liquid; electrical (D.C., A.C., RF/microwave); and optical and radiation. The capabilities developed include unique capabilities in many areas of measurement and engineering expertise to develop measurement techniques and resolve measurement problems in these major areas. FM and T Metrology was established in 1958 to provide a measurement base for the Department of energy`s Kansas City Plant. The Metrology Engineering Department provides the expertise to develop measurement capabilities for virtually any type of measurement which falls into the broad areas listed above. The engineering staff currently averages almost 16 years of measurement experience. A strong audit function has been developed to provide a means to evaluate the ...
1997-06-01
Chromosomal damage in human lymphocytes from radio-isotope therapy
International Nuclear Information System (INIS)
(Dec 1973). United Kingdom Stevenson, AC Medical Research Council, Oxford
... }wtv{tv|l^\\h xuwxsqs |qhlnnusnvsqvwzvsrsstrpokfb`ba`]chc][TSWg nkjsrkjkdcenz |{|{{{w khghfbddkmhkljnkeexhgrnimppqsovr|umnmgloplqqqv ~soljowwvvt{|rsuqtp ...
Hydroelectric power in Switzerland: large growth potential by increasing the installed power
International Nuclear Information System (INIS)
Due to its important hydroelectric power generation facilities (about 525 plants with a total power of 13,314 MW producing about 35.3 TWh annually) Switzerland plays an important role in the interconnected European power system. Large artificial storage lakes in the Swiss Alps can generate peak power during hours of highest demand: 9700 MW are available from accumulated energy and the total power of pumped-storage facilities amounts to 1700 MW. The latter allow refilling the reservoirs at periods of low power demand and generating power at periods of peak demand. In the case of favorable conditions, the yearly average power production could be increased by 6% and the production during the winter period (October to March) by 20% by the year 2020. However, looking forward to the year 2050, the annual production is expected ...
The effect of flow velocity on pitting corrosion and stress corrosion cracking of reactor materials
International Nuclear Information System (INIS)
This paper describes two research programs which are currently underway in the author's laboratory to investigate the effect of fluid flow on the degradation of power plant materials in high temperature/high pressure aqueous environments. These programs include the design and operation of a controlled hydrodynamic corrosion testing apparatus that can be used to study the general and localized corrosion characteristics of alloys in simulated nuclear reactor environments, and a study of the effect of flow velocity on the stress corrosion cracking of ASTM A508 C1.2 steel and Type 304SS in simulated BWR heat transport fluids.
Enhanced LMR core cooling utilizing passive vortex devices
International Nuclear Information System (INIS)
This paper reports several design options for improved passive circulation flow investigated for use in small, modular liquid metal cooled reactors (LMRs). The purpose is to enhance the transition to natural convection cooling following loss of forced circulation flow, reducing thermal transients experienced by the fuel and possibly eliminating the need for emergency pony-motor flow. Design details to minimize pressure drops may also enhance maximum equilibrium power levels possible under natural circulation only.
1988-05-01
Enhanced LMR [liquid metal reactors] core cooling utilizing passive vortex devices
International Nuclear Information System (INIS)
Several design options for improved passive circulation flow have been investigated for use in small, modular liquid metal cooled reactors (LMRs). The purpose is to enhance the transition to natural convection cooling following loss of forced circulation flow, reducing thermal transients experienced by the fuel and possibly eliminating the need for emergency pony-motor flow. Design details to minimize pressure drops may also enhance maximum equilibrium power levels possible under natural circulation only.
1988-05-01
A study on diagnostic techniques of pump operating condition
Energy Technology Data Exchange (ETDEWEB)
The scope and contents investigate and reviewed are as follows : establishment of study plan and references survey, review of related problems and inservice test standards of safety injection pump in use nuclear power plant, review of the study results in laboratory, the theoretical investigation of temperature rise according to mini-flow rate of pump, mini-flow rate working characteristics of high and low pressure injection pumps at nuclear power plants, setup of testing equipment for measuring ampere, discharge pressure and vibration, selection and behaviors analysis of major parameters concerning pump degradation.
1998-03-15
Steam generator design improvements for the candu wolsung nuclear power plant
International Nuclear Information System (INIS)
Design considerations are given for the secondary side region of a vertical U-tube nuclear stream generator with an integral preheater. The thermal shield design, the novel recirculating water flow distribution scheme, the high porosity tube supports used in the parallel flow regions, and the U-bend supports are discussed for the Wolsung Plant steam generators. Experimental and analytical development programs undertaken to verify the design features are outlined.
1978-01-01
Oil cable pumping plant. Pumpestasjon
Energy Technology Data Exchange (ETDEWEB)
The invention deals with a pumping plant for oil filled power cables. An air driven piston type pump is used as primary pump. A PLS (Programmable Logic control System) is used to control the oil flow to the cable(s). Improvements of the pump includes means for ensuring that the pump piston is operated also at low pressure and flow, and means for sealing off the piston rod to ensure maximum life of seals, to facilitate detection of possible leakages and to avoid contamination of the cable oil. 3 figs.
1988-12-27
British Library Electronic Table of Contents (United Kingdom)
Results are given of numerical simulation of three-dimensional pattern of flow of a two-phase steam-water mixture in the house of a PGV-1000 horizontal steam generator obtained using the BAGIRA best-estimate thermohydrodynamic computer codes. The space distributions of velocities and local void fractions in the steam generator housing for different modes of operation of power-generating unit are calculated and compared with available experimental data.
2008-01-01
Results are given of numerical simulation of three-dimensional pattern of flow of a two-phase steam-water mixture in the house of a PGV-1000 horizontal steam generator obtained using the BAGIRA best-estimate thermohydrodynamic computer codes. The space distributions of velocities and local void fractions in the steam generator housing for different modes of operation of power-generating unit are calculated and compared with available experimental data.
2008-05-01
Applying fluidics to reactor safety and reprocessing
International Nuclear Information System (INIS)
Large scale flows of liquids can be controlled by using power fluidic devices that harness the hydrodynamic properties of liquids rather than use moving parts. Included among the fluidic devices considered are fluidic pumps, reverse flow diverters, fluidic diodes and vortex amplifiers. These devices are of potential use in the nuclear industry, particularly in reprocessing. (U.K.).
Development of a HVDC prototype breaker. Final report
Energy Technology Data Exchange (ETDEWEB)
The significant design features of a high-voltage dc (HVDC) circuit breaker based on the commutation concept were developed. Tests of components indicate the breaker is capable of interrupting a fault current of 10 kA on a 400 kV system and absorbing up to 10 MJ of system energy without generating more than 1.6 per unit (P.U.) voltage of the system. Interactions of the breaker with a three-terminal network were studied, using a system simulator. An ultrafast hydraulic actuator system was developed for this program which enables the breaker to initiate the current limiting process within 5 ms after receipt of a trip signal. A new hydraulic valve, operated by a repulsion coil, minimizes the delay before motion begins. Interruption will occur in series-connected vacuum interrupters. A 400 kV circuit breaker is estimated to require eight breaks in series. Only a single break was tested as part of this program because of the scale and cost required for multibreak tests. System energy will ...
1980-06-01
Environmental impacts of nuclear and coal-fired power plants
International Nuclear Information System (INIS)
The current situation in the development of nuclear power in the world and in Czechoslovakia is briefly outlined and the possibilities are discussed of alternative energy resources. The environmental impact is described of conventional power plants firing coal; sulphur and nitrogen oxides are mentioned and their environmental impacts shown. Their quantities and the quantities of other gaseous, liquid and soid wastes produced by coal power plants are given. Annual estimates are presented of radioactive material emissions; trace amount emissions of toxic metals and their ecological risks are shown. Concern over the increasing concentration of CO_2 in the atmosphere is voiced. For nuclear power plants, the amount of radionuclides in stack emission and of those released into water flows is tabulated. Their effect on the aqueous ecosystem is characterized as is thermal pollution of water ...
1984-01-01
A study of flow boiling phenomena using real time neutron radiography
International Nuclear Information System (INIS)
The operation and safety of both fossil-fuel and nuclear power stations depend on adequate cooling of the thermal source involved. This is usually accomplished using liquid coolants that are forced through the high temperature regions by a pumping system; this fluid then transports the thermal energy to another section of the power station. However, fluids that undergo boiling during this process create vapor that can be detrimental, and influence safe operation of other system components. The behavior of this vapor, or void, as it is generated and transported through the system is critical in predicting the operational and safety performance. This study uses two advanced penetrating radiation techniques, Real Time Neutron Radiography (RTNR), and High Speed X-Ray Tomography (HS-XCT), to examine void generation and transport behavior in a flow boiling system. The geometries studied were tube side flow ...
1346-01-01
Energy saving dc-dc converter circuit
Energy Technology Data Exchange (ETDEWEB)
An energy saving dc-dc converter circuit is disclosed having two energy efficient means which operate in tandem, an energy conserving means and a voltage doubling means. These energy efficient means are applied in combination with elements commonly found in dc-dc converter circuits, namely an ac voltage generator, a transformer for stepping up the generated ac voltage, and means for storing the converted dc voltage. The energy conserving means is connected to the dc voltage storage means. It comprises a resettable inhibit circuit which cuts off the provision of dc voltage for conversion for a predetermined interval when the output of the converter exceeds a predetermined level. The voltage doubling means is reponsive to outputs of the inhibit circuit of the energy conserving means and the ac voltage generator. It provides a phase inverted waveform of the generated ac voltage on one of two leads to the ...
1982-06-22
Energy Technology Data Exchange (ETDEWEB)
The electrochemical capacitor devices described in this report were deliverables from the US Department of Energy--Idaho Operations Office (DOE-ID) Contract No. DE-AC07-92ID13404 as part of the US Department of Energy`s (DOE) High Power Energy Storage Program. The Idaho national Engineering and Environmental Laboratory (INEEL) has responsibility for technical management, testing, and evaluation of high-power batteries and electrochemical capacitors under this Program. The DOE has developed various electrochemical capacitors as candidate power assist devices for the Partnership for a New Generation of Vehicles (PNGV) fast response engine requirement. This contract with Maxwell Energy Products, Inc. (Maxwell) was intended to develop a high-energy-density, high-power-density ultracapacitor that is capable of load leveling batteries in electric vehicles. The performance criteria for ...
1998-04-01
International Nuclear Information System (INIS)
The General Electric Test Reactor emergency cooling system performance was tested by intentionally scramming the reactor and then terminating the power to the primary pump. Certain transient thermal-hydraulic data were obtained preceding and during the established natural convection cooling loop composed of the upward flow through the core and the downward flow through the pool. An analysis was performed to permit the data to be extrapolated to obtain distributed fuel element flow rates and bulk temperature rises during the established cooling loop. The earliest time for the quasi-steady natural cooling loop to develop is about 2.5 min following scram. The cladding hot-spot temperature does not exceed the local saturation temperature after quasi-steady flow is established. Data are presented to assist in the modeling of the GETR natural convection loop. Semi-empirical relationships ...
The inertial dynamics of thin film flow of non-Newtonian fluids
Consider the flow of a thin layer of non-Newtonian fluid over a solid surface. I model the case of a viscosity that depends nonlinearly on the shear-rate; power law fluids are an important example, but the analysis here is for general nonlinear dependence. The modelling allows for large changes in film thickness provided the changes occur over a large enough lateral length scale. Modifying the surface boundary condition for tangential stress forms an accessible base for the analysis where flow with constant shear is a neutral critical mode, in addition to a mode representing conservation of fluid. Perturbatively removing the modification then constructs a model for the coupled dynamics of the fluid depth and the lateral momentum. For example, the results model the dynamics of gravity currents of non-Newtonian fluids even when the flow is not very slow.
2007-01-01
British Library Electronic Table of Contents (United Kingdom)
An experimental investigation on the thermal decomposition of CH4 into C and H2 was carried out using a 5kW particle-flow solar chemical reactor tested in a solar furnace in the 1300-1600K range. The reactor features a continuous flow of CH4 laden with mm-sized carbon black particles, confined to a cavity receiver and directly exposed to concentrated solar irradiation of up to 1720 suns. The reactor performance was examined for varying operational parameters, namely the solar power input, seed particle volume fraction, gas volume flow rate, and CH4 molar concentration. Methane conversion and hydrogen yield exceeding 95% were obtained at residence times of less than 2.0s. A solar-to-chemical energy conversion efficiency of 16% was experimentally reached, and a maximum value of 31% was numer...
2009-01-01
Flow field and heat transfer associated with laminar flow over a forward-facing step
The flow and heat transfers associated with a plane laminar flow past a forward-facing step were analyzed using a power-law numerical scheme combined with a false vorticity-stream function approach. To improve the traditional wall-vorticity boundary condition, a novel method, based on an accurate description of the nonslip wall condition, was developed and utilized. The convergence for a 56 x 49 grid system was obtained in about 350 iterations. The computed reattachment distances in the upper separated region agree with the available experimental data for a blunt plate. The heat transfer augmentation is significant across the step; however, it is counterbalanced by the deterioration of heat transfer immediately upstream of the step.
1986-01-01
Two-phase flow regime management for in-space power rejection management -- Feasibility study
Energy Technology Data Exchange (ETDEWEB)
A novel two-phase flow management process useful for active thermal power rejection in space is introduced. The process serves as a condenser in a Rankine cycle and is applicable for thermal energy management needs in low gravity environments. Benefit is derived from the ability to utilize the high specific energy transport capability of two-phase flow, while not requiring mass-intensive solutions nor complex control strategies to maintain design energy balance integrity. Initial design calculations for a hypothetical space vapor cycle demonstration experiment were done and a steady-state computer model of the novel condensing process was created and used to evaluate its potential to maintain the design energy balance of the experiment. The experiment (approximately 28 kg) was a supercritical organic thermal loop operating between 500 and 400 Kelvin at a mass flow of 1 grain per second; using R-113 as ...
1995-12-31
International Nuclear Information System (INIS)
The natural circulation experiments were conducted to confirm the cooling capability and the flow characteristics of the natural convection in the HANARO (Hi-flux Advanced Neutron Application Reactor). The tests were done at the power levels of 2%, 3% and 4% (1.2MW_t_h) of full power. The flow rates and temperatures at various locations of the primary and secondary cooling loops were measured at each power level. The temperature distributions in the chimney and the pool were also obtained. Through tests, the flow paths of the natural circulation and the cooling capability of the reactor were confirmed as designed. In addition, the simulation for the natural circulation tests was made by using RELAP5/KMRR, which was modified from RELAP5/MOD2 for applying to the HANARO conditions. The simulation results show that RELAP5/KMRR gives reasonable predictions for the ...
The potential of power fluidics for plant protection
International Nuclear Information System (INIS)
The possibility of using Direct Flow Control (DFC) to avoid catastrophic accidents due to containment breaches in chemical plant is discussed. Recommendations are made for locating fluidic elements, and the effectiveness of simple DFC protection is analysed. More powerful methods of protection are outlined using spin diversion and the complementary properties of fluidic and conventional valves are exploited. (author).
Negative ion formation in magnetically insulated transmission lines
Energy Technology Data Exchange (ETDEWEB)
Negative ion intensities of over 3 x 10/sup 5/ A/m/sup 2/ at energies of 2 MeV have been measured in a magnetically insulated transmission line. This negative ion production can affect the power flow in multiterawatt pulsed power devices, and may also have applications in the generation of high-intensity neutral or negative ion beams.
1982-05-01
Life time management at the Dukovany nuclear power plant
International Nuclear Information System (INIS)
The paper discusses the role of the Life Management Programme in ensuring a safe operation of the Dukovany nuclear power plant. The Programme involves the following major items: (i) primary circuit materials degradation assessment, (ii) pipeline damage control by the Flow Assisted Corrosion Monitoring and Prediction Programme, and (iii) the DIALIFE diagnostic system. (author)
Irradiation data for the MFA-1 and MFA-2 tests in the FFTF
Energy Technology Data Exchange (ETDEWEB)
This report provides key information on the irradiation environment of the MONJU fuel tests MFA-1 and MFA-2 in the Fast Flux Test Facility (FFTF). This information includes the fission powers, neutron fluxes, sodium temperatures and sodium flow rates in MFA-I, MFA-2 and adjacent assemblies. It also includes MFA-1 and MFA-2 compositions as a function of exposure. The work was performed at the request of Power Reactor and Nuclear Fuels Corporation (PNC) of Japan.
1997-04-24
Energy Technology Data Exchange (ETDEWEB)
The flow of current inside a conductor leads to its overheating. This conductor is also submitted to other climatic phenomena, such as wind, sun light and ambient temperature. The knowledge of this overheating is important to ensure a functioning temperature compatible with the materials used for the conductor manufacturing and with the dip of overhead power lines above the ground and buildings. On the other hand, according to the Laplace works, the flow of current inside parallel conductors induces electromagnetic forces inside them, proportional to the product of currents in both conductors. In the case of short-circuit between aerial power lines or between flexible cables, electrodynamical stresses (traction and flexion) are applied to insulators and holders and important swinging of the lines can be observed. These stresses can be extremely important and must be considered in the design of overhead ...
1997-05-01
Transient overvoltages and overcurrents during line fault tests on the Hokkaido-Honshu HVDC line
Energy Technology Data Exchange (ETDEWEB)
A series of line fault tests have been conducted at completion of Stage I of the Hokkaido-Honshu HVDC Link of Electric Power Development Co., Ltd., prior to its commercial operation, in order to study transient overvoltages and overcurrents and to confirm safety operation of system protecting devices in case of DC transmission line faults. The Hokkaido-Honshu HVDC Link is a metallic return HVDC overhead line and cable transmission system, currently being a monopolar system. For this, measurements were conducted this time on reverse polarity overvoltages occurring on main line cable, return line overvoltages, fault arc dynamic characteristics, and DC bypass current through the AC system. The results obtained were then compared with the analysis results by the HVDC surge similator or digital simulation conducted for system design prior to the field tests. As a result, a close accordance was found between them, in confirmation of the effectiveness ...
1982-08-01
Serviceability of steam generators at NPPs with reactors of the WWER-440 and WWER-1000 types
Energy Technology Data Exchange (ETDEWEB)
Steam generators (SG) are the weak link of nuclear power plants, their service life is shorter than the service life of other NPP components. This paper is dedicated to a statistical analysis of SG damages and failures. Heat exchanging tubes (HET) are the most damaged elements in SG, there are on average 286 plugged or repaired tubes in each operating SG. The usually mechanisms of tube failure are the following: denting, corrosion at tube outside, pitting, fretting, and circular crack propagation. Most of damages are located in the transition zone above a tube plate. This study shows that the factors that are involved in the SG HET fault probability are: - design features of SG and secondary equipment elements (high pressure feed heaters (HPFH), low pressure feed heater (LPFH)), - water chemistry at different points of condensate feed pipe, composition and density of deposits on HET surface, efficiency of mechanical and chemical washing, - the physical and chemical ...
2002-07-01
Design of an onboard battery charger for an electric vehicle
Energy Technology Data Exchange (ETDEWEB)
This report describes the design of an on-board battery charger for an electric car. There are already various battery charger units on the market. However, these are not specifically designed for this application, and consequently do not provide an ideal solution. Because these products are not specific to one application, and instead opt to cover a variety of briefs, they are not ideal. They also tend to be heavier and more expensive than if the charger was built specifically for one purpose. The main design considerations were that the charger should be compact and lightweight. It was also specified that the design should be able to operate using either the single-phase or three-phase AC supply. Before the design process for the battery charger could commence, it was necessary for the author to get an appreciation of power electronics, since he had no previous experience in the subject. The author focused his attention on areas of the ...
2001-07-01
Thomson scattering: a powerful diagnostic tool of plasma physics
International Nuclear Information System (INIS)
Thomson scattering is the process in which a low-energy photon scatters from a free electron. When a laser pulse propagates through a plasma, the spectrum of the scattered light due to the Thomson scattering is proportional to the power spectrum of the electron density fluctuations, i.e., dynamic form factor, from which various plasma parameters can be inferred, such as electron temperature and plasma flow velocity. After years of development. Thomson scattering has now become a powerful diagnostic tool of plasma physics. (authors)
2008-08-01
Feedwater control device of the steam generator in an atomic power station
International Nuclear Information System (INIS)
Purpose: In a case of automatically controlling the water level at the time of generating a lower power, to impact the followability of the control necessary for the power variation of the steam generator thereby to obtain good controllability. Constitution: A signal of deviation of water level of a steam generator and its set value and a signal of a difference between the temperature of the primary coolant in the high temperature side pipeline and that of the primary coolant in the low temperature side pipeline are used to automatically or manually control the flow quantity of water fed to the steam generator. (Yoshihara, H.).
Boiling transition under thermal hydraulic instability in rod bundle
International Nuclear Information System (INIS)
Experiments have been performed on the electrically heated rod bundles to investigate the characteristics of the boiling transition under flow oscillation (OSBT) during thermal hydraulic instability. After determining the instability threshold power (Q/sub OS/), the electrical power to the test section was increased further up to the threshold power (Q/sub OSBT/) at which it was detected by the thermocouples that the boiling transition (BT) occurred and the heater rod temperature reached 613 K. Experimental results show that Q/sub OSBT/ is larger than Q/sub OS/ by a certain margin, which depends on the test conditions.
Simple Power Control for Sensorless Induction Motor Drives Fed by a Matrix Converter
DEFF Research Database (Denmark)
This paper presents a new and simple method for sensorless control of matrix converter drives using a power flowing to the motor. The proposed control algorithm is based on controlling the instantaneous real and imaginary powers into the induction motor. To improve low-speed sensorless performance, the nonlinearities of a matrix converter drive such as commutation delays, turn-ON and turn-OFF times of switching devices, and on-state switching device voltage drop are modeled using a PQ power transformation and compensated using a reference power control scheme. The proposed sensorless control method is applied for the induction motor drive using a 3 kW matrix converter system. Experimental results are shown to illustrate the feasibility of the proposed strategy. Udgivelsesdato: September
2008-01-01
HVDC submarine power cables systems state of the art and future developments
Energy Technology Data Exchange (ETDEWEB)
The paper begins with an introduction on the reasons that lead to the use of HVDC submarine cable links. The main aspects for the choice of direct current are presented as well as the advantages deriving from the utilization of submarine cables. The second part is dedicated to a discussion on the various type of insulation that could be used in power cables and their possible application to HVDC submarine cables. In the following there is a description of the main characteristics and technical details of some particular project that at present time (1995) are in progress. Two projects are briefly presented: Spain-Morocco, a 26 km long interconnection for the transmission, in a first phase, of 700 MW from Spain to Morocco at 400 kV a.c. by means of three cables, plus one spare, of the fluid filled type. The cables are designed for a future change to d.c. 450 kV, allowing a transmission of 500 MW each (i.e., 2 GW total). One of the peculiarities ...
1995-12-31
Energy Technology Data Exchange (ETDEWEB)
This report covers application of Argonne National Laboratory`s (ANL`s) computer codes to simulation and analysis of components of the magnetohydrodynamic (MHD) power train system at the Component Development and Integration Facility (CDIF). Major components of the system include a 50-MWt coal-fired, two-stage combustor and an MHD channel. The combustor, designed and built by TRW, includes a deswirl section between the first and the second-stage combustor and a converging nozzle following the second-stage combustor, which connects to the MHD channel. ANL used computer codes to simulate and analyze flow characteristics in various components of the MHD system. The first-stage swirl combustor was deemed a mature technology and, therefore, was not included in the computer simulation. Several versions of the ICOMFLO computer code were used for the deswirl section and second-stage combustor. The MGMHD code, upgraded with a slag current leakage ...
1997-11-01
Zero-G two phase flow regime modeling in adiabatic flow
Energy Technology Data Exchange (ETDEWEB)
Two-phase flow, thermal management systems are currently being considered as an alternative to conventional, single phase systems for future space missions because of their potential to reduce overall system mass, size, and pumping power requirements. Knowledge of flow regime transitions, heat transfer characteristics, and pressure drop correlations is necessary to design and develop two-phase systems. This work is concerned with microgravity, two-phase flow regime analysis. The data come from a recent sets of experiments. The experiments were funded by NASA Johnson Space Center (JSC) and conducted by NASA JSC with Texas A M University. The experiment was on loan to NASA JSC from Foster-Miller, Inc., who constructed it with funding from the Air Force Phillips Laboratory. The experiment used R12 as the working fluid. A Foster-Miller two phase pump was used to circulate the two phase mixture and allow ...
1993-01-15
Zero-G two phase flow regime modeling in adiabatic flow
International Nuclear Information System (INIS)
Two-phase flow, thermal management systems are currently being considered as an alternative to conventional, single phase systems for future space missions because of their potential to reduce overall system mass, size, and pumping power requirements. Knowledge of flow regime transitions, heat transfer characteristics, and pressure drop correlations is necessary to design and develop two-phase systems. This work is concerned with microgravity, two-phase flow regime analysis. The data come from a recent sets of experiments. The experiments were funded by NASA Johnson Space Center (JSC) and conducted by NASA JSC with Texas A ampersand M University. The experiment was on loan to NASA JSC from Foster-Miller, Inc., who constructed it with funding from the Air Force Phillips Laboratory. The experiment used R12 as the working fluid. A Foster-Miller two phase pump was used to circulate the two phase mixture and ...
1993-01-10
Fish schooling as a basis for vertical axis wind turbine farm design
International Nuclear Information System (INIS)
Most wind farms consist of horizontal axis wind turbines (HAWTs) due to the high power coefficient (mechanical power output divided by the power of the free-stream air through the turbine cross-sectional area) of an isolated turbine. However when in close proximity to neighboring turbines, HAWTs suffer from a reduced power coefficient. In contrast, previous research on vertical axis wind turbines (VAWTs) suggests that closely spaced VAWTs may experience only small decreases (or even increases) in an individual turbine's power coefficient when placed in close proximity to neighbors, thus yielding much higher power outputs for a given area of land. A potential flow model of inter-VAWT interactions is developed to investigate the effect of changes in VAWT spatial arrangement on the array performance coefficient, which compares the expected ...
2010-09-01
Energy Technology Data Exchange (ETDEWEB)
A characteristic trait of Francis turbines operating at low-head is pressure pulsations that occur during certain load levels of the generator. These stem from pressure variations across the turbine due to pulsating flow in the draft-tube. This surging action of the water column is related to draft-tube geometry and flow-rate of water in the penstock. The pressure pulsations cause torque variations on the turbine and corresponding electric power pulsations. If electric power is used as a feedback signal to the Power System Stabilizer (PSS), then Mvar and terminal voltage pulsations will occur when the generator is operating in the ``rough zone``. This paper describes field test results for investigating feedforward control from the penstock, draft tube and spiral case pressure to reduce the effects of Mw pulsations on PSS output signals. This investigation involved a PSS with ...
1993-12-01
A market power model with price caps and compact DC power flow constraints
International Nuclear Information System (INIS)
This paper presents a spatial gaming model with price caps for deregulated electricity markets. There has been heated debate on price caps that have been enforced in deregulated electricity markets. Opponents argue that price caps may send wrong economic signals while advocates argue that price caps are good for damping market power. This paper does not intend to take a stand in the argument. Given the fact that price caps are enforced in several deregulated regional electricity markets in the US, a logical step is to reflect this reality in gaining modeling. However, current gaining models have not included any price cap formulation. This paper is the first one to address the issue. DC power flow equations are used for representing the spatial nature of an electrical network. An algorithm is proposed to find a generalized Nash equilibrium under the enforcement of price caps based on the Kuhn-Tucker Vector Optimization ...
2003-05-01
Effect of Infrared Pulsated Laser on the Dielectric Properties of Makrofol Polycarbonate
International Nuclear Information System (INIS)
Makrofol-De 1-1 CC Polycarbonate is a class of polymeric solid state nuclear track detectors which has many applications in various industrial fields. A study of the modification possibility of the dielectric properties of Makrofol polymer using laser irradiation has been carried out. In tbe present work, Makrofol samples were irradiated using different fluences between 0.47 and 10.4 J/cm"2 of 5 watt infrared pulsated laser. The mollifications in the laser irradiated Makrofol samples have been studied as a function of fluence using dielectric constant #epsilon#', dielectric loss #epsilon#"and AC conductivity #sigma#_AC measurements. Tbe frequency dependencies (100 Hz-5 MHz) of #epsilon#', #epsilon#"and #sigma#_AC at 35 degree c were investigated. The dielectric constant #epsilon#', dielectric loss #epsilon#"and AC conductivity #sigma#_AC were found to increase at heating up to 100 ...
Vortex-Excited Vibrations of Uniform Pivoted Cylinders in Uniform and Shear Flow
The vortex-excited dynamics of a uniform pivoted cylinder in uniform and sheared flow was investigated experimentally. The experiments were numerically simulated using a diffusive Van der Pol oscillator model developed by Balasubramanian & Skop recently. Salient features of the experimental investigations and the numerical simulations are presented here. Comparisons between the experimentally recorded and numerically predicted structural response to vortex-excited vibrations, power spectral density measurements of near-wake velocity fluctuations and lock-in ranges are made. A comparison of the numerical predictions and the experimental data reveals good agreement.
2000-01-01
Self-magnetically insulated, high-voltage transmission lines are used in inertial confinement fusion particle accelerators in order to transmit power from the vacuum insulator to the diode. This paper describes a time-dependent 2-D code (MITL) for calculating (for planar or triplate geometries) the motion of test electrons through the tapered input or output convolutes of such lines. MITL results show that the electron canonical momentum in the direction of the flow changes as the electron passes through the convoluted geometry; it is suggested that these electrons lead to losses observed in long self-magnetically insulated lines.
1979-01-01
Loss of flow accident analysis of a water-cooled fusion reactor
International Nuclear Information System (INIS)
Within the APROS simulation environment we have built a thermo-hydraulic model of a conceptual fusion power plant which is water cooled and uses lithium-lead for tritium breeding. For the safety assessment of this design we have studied an accident sequence which starts from a loss or coolant flow then leads to first wall breach and pressurisation of the vacuum vessel. Simulations have revealed strong pressure transients which can be alleviated by design changes. One goal is to verify the adequacy of the containment design: it remains intact at least 14 h without any mitigating efforts. Estimates for radioactive releases are obtained. (author)
2003-08-25
Linearization of Valve Flow Characteristics for Steam Turbine Control
Energy Technology Data Exchange (ETDEWEB)
The control valve for a large steam turbine must be operated linearly to be run by an automatic control system in a power plant. It is, however, found that the flow increase is much greater for a given valve position change near the closed end of travel than it is near the open end. Accordingly, the desired linearization will be achieved if the valve is opened less near the closed end of travel and greater near the open end. The previous way for linearization was to utilize the cams, which is called the mechanical hydraulic control (MHC). The MHC was afterward improved by producing the nonlinear electric compensation to the nonlinear system of control valves, viz. the electro hydraulic control (EHC)
2009-10-15
Linearization of Valve Flow Characteristics for Steam Turbine Control
International Nuclear Information System (INIS)
The control valve for a large steam turbine must be operated linearly to be run by an automatic control system in a power plant. It is, however, found that the flow increase is much greater for a given valve position change near the closed end of travel than it is near the open end. Accordingly, the desired linearization will be achieved if the valve is opened less near the closed end of travel and greater near the open end. The previous way for linearization was to utilize the cams, which is called the mechanical hydraulic control (MHC). The MHC was afterward improved by producing the nonlinear electric compensation to the nonlinear system of control valves, viz. the electro hydraulic control (EHC)
2009-10-01
Effect of induced instability by subcooled boiling vibration of heated rod
International Nuclear Information System (INIS)
In the present study, a subcooled boiling loop with an annular flow on the electrically heated rod was used to make an experimental approach to investigate the effects of induced instability by the subcooled boiling on vibration of the rod in different subcooled conditions. The results show the intensive subcooled-boiling-induced vibration (SBIV) which is highly depend on dynamic force generated by fast vapor bubbles growth and collapse whilst they still attach to, or slide along, the heating surface at high loading heat fluxes. These behaviors were strongly influenced by the conditions of subcooling temperature, flow rate and linear power density. (author)
1998-05-01
Conditional risk assessment of SNR 300 in case of an unprotected loss of flow accident
International Nuclear Information System (INIS)
This paper gives a summary of a risk study assuming unprotected loss of flow (ULOF) in the SNR 300. This study was initiated in 1979/80 by the Karlsruhe Nuclear Research Center and performed in close cooperation with Science Applications Inc., Palo Alto, USA, and Interatom Company. Part of the results also was integrated in the 'Risk Related Analysis for the SNR 300' carried out by the Gesellschaft fuer Reactorsicherheit. The character of the study described here is similar to other risk studies like the Reactor Safety Study and the German Risk Study for Nuclear Power Plants. The objectives and the methodology of the analyses are described and its results are discussed. (orig./RW).
A parametric analysis of decay ratio calculations in a boiling water reactor model
Energy Technology Data Exchange (ETDEWEB)
The results of an investigation of the effects of several parameters on the reactivity instability of a Boiling Water Reactor (BWR) calculational model are summarized. Calculations were performed for a typical BWR operated at low flow conditions, where reactivity instabilities are more likely to occur. The parameters investigated include the axial power shape (characterized by two separate parameters), the core pressure, and operating flow. All calculations were performed using the LAPUR code which was developed at the Oak Ridge National Laboratory for the dynamic modeling of large BWR's. 4 refs., 8 figs.
1989-01-01
Energy Technology Data Exchange (ETDEWEB)
This paper described the application of an AC surface probe, similar to presently used eddy current probes, to the measurement of DC transport critical currents and critical state dissipation in high {Tc} superconductors. It has been shown that the probe can provide quantitative measurement of the full field penetration in superconducting samples by measuring the response of AC induced screening currents for superconducting materials in the form of tapes with overlayers of silver. In this manner, the AC probe can be used to replace the contact DC probe for determining critical currents in a noncontacting and local manner suitable for scanning over or along the sample.
1992-10-01
Single parameter analysis of hysteretic magnetic flux trapping in high T_c superconductor ribbon
International Nuclear Information System (INIS)
This paper described the application of an AC surface probe, similar to presently used eddy current probes, to the measurement of DC transport critical currents and critical state dissipation in high T_c superconductors. It has been shown that the probe can provide quantitative measurement of the full field penetration in superconducting samples by measuring the response of AC induced screening currents for superconducting materials in the form of tapes with overlayers of silver. In this manner, the AC probe can be used to replace the contact DC probe for determining critical currents in a noncontacting and local manner suitable for scanning over or along the sample.
1992-07-19
Energy Technology Data Exchange (ETDEWEB)
This paper described the application of an AC surface probe, similar to presently used eddy current probes, to the measurement of DC transport critical currents and critical state dissipation in high [Tc] superconductors. It has been shown that the probe can provide quantitative measurement of the full field penetration in superconducting samples by measuring the response of AC induced screening currents for superconducting materials in the form of tapes with overlayers of silver. In this manner, the AC probe can be used to replace the contact DC probe for determining critical currents in a noncontacting and local manner suitable for scanning over or along the sample.
1992-01-01
Review of passive heat transfer augmentation techniques
Energy Technology Data Exchange (ETDEWEB)
Heat transfer augmentation techniques (passive, active or a combination of passive and active methods) are commonly used in areas such as process industries, heating and cooling in evaporators, thermal power plants, air- conditioning equipment, refrigerators, radiators for space vehicles, automobiles, etc. Passive techniques, where inserts are used in the flow passage to augment the heat transfer rate, are advantageous compared with active techniques, because the insert manufacturing process is simple and these techniques can be easily employed in an existing heat exchanger. In design of compact heat exchangers, passive techniques of heat transfer augmentation can play an important role if a proper passive insert configuration can be selected according to the heat exchanger working condition (both flow and heat transfer conditions). In the past decade, several studies on the passive techniques of heat transfer augmentation ...
2004-12-01
Thermalhydraulic Characteristics for Wolsung-1 after retubing
International Nuclear Information System (INIS)
The ROP margin in a CANDU reactor is decreasing over time due to the Primary Heat-Transport System (PHTS) aging effect. Adjustment of the ROP trip setpoint is required to maintain a high trip-probability and ROP trip effectiveness. Especially, for Wolsong-1, which is scheduled to change the old pressure tubes in 2009, the trend of ROPT after the retubing should be reevaluated. Before setting a ROPT, the main thermal characteristics including Critical Channel Power (CCP) should be calculated by the NUCIRC code. In this paper, the thermalhydraulic evaluation for Wolsung-1 was conducted with the updated Wolsung-1 PHTS data. Specifically, for the case of 0 EFPY (Effective Full Power Year) and 11 EFPY after the retubing, the distribution of the channel flow rate, channel exit quality, critical channel power, and critical power ratio (CPR) of the Wolsong-1 aged plant are calculated
2009-05-01
Power generation from biomass residues using the gasifier/dual-fuel engine technique
Energy Technology Data Exchange (ETDEWEB)
A process is described for converting organic waste into a combustible gas for use in a heavy duty thermal engine. The engines best suited for this operation are of the dual-fuel type whose output power results from the simultaneous work of 2 combustibles. The gas flow rate is controlled by the desired power output, while diesel fuel injection remains constant regardless of engine load. The low BTU gas produced by the gasification of dry wastes is a mixture of CO, H/sub 2/ CH/sub 4/, CO/sub 2/ and N/sub 2/. Diesel fuel savings under usual operating conditions is no less than 80% of the consumption of conventional diesel engines of identical power. Characteristics of the low Btu gas engines are described as are the characteristics of the gasifying equipment. Applications for this process are suggested. (DMC)
1980-01-01
3D modelling as a support to thermal-hydraulic safety analyses with standard codes
Energy Technology Data Exchange (ETDEWEB)
A three-dimensional (3D) thermal-hydraulic model and a numerical procedure for the simulation and analysis of a steady-state, as well as transient operation of nuclear power plant components are presented. A two-fluid approach is applied to modelling of two-phase flow. Thermal-hydraulics of a horizontal steam generator in the WWER 1000 nuclear power plant has been simulated at the full load, steady-state operation. A comparison of the numerical results with data measured at the NPP Novovoronjezh shows good agreement. 3D numerical results can be used in plant design or retrofitting, in nuclear power plant operation and safety analysis and as improvement of existing one-dimensional thermal-hydraulics models of the horizontal steam generator which are assessed by system codes used for the nuclear power plant safety analyses. (author)
1999-07-01
3D modelling as a support to thermal-hydraulic safety analyses with standard codes
International Nuclear Information System (INIS)
A three-dimensional (3D) thermal-hydraulic model and a numerical procedure for the simulation and analysis of a steady-state, as well as transient operation of nuclear power plant components are presented. A two-fluid approach is applied to modelling of two-phase flow. Thermal-hydraulics of a horizontal steam generator in the WWER 1000 nuclear power plant has been simulated at the full load, steady-state operation. A comparison of the numerical results with data measured at the NPP Novovoronjezh shows good agreement. 3D numerical results can be used in plant design or retrofitting, in nuclear power plant operation and safety analysis and as improvement of existing one-dimensional thermal-hydraulics models of the horizontal steam generator which are assessed by system codes used for the nuclear power plant safety analyses. (author)
1999-04-19
Natural convection cooling of a vertical channel
International Nuclear Information System (INIS)
An experimental program has been conducted to determine the feasibility of natural convection cooling of a reactor following a beyond-design-based accident. The particular application under consideration was the heavy-water new production reactor. The questions to be resolved include the verification that a natural convection cooling pattern would be established and the determination of the power limit for which convective cooling will occur for a significant period of time. In the experiment, the reactor configuration was simulated using small-diameter vertical heated tubes in parallel with a large-diameter bypass line. Following a loss-of-flow event, the flow in the bypass line will reverse direction and pass through the heated channel by means of natural convection. If, however, the channel power is too high, void formation will block the channel and prevent the reverse flow ...
1993-11-14
Energy Technology Data Exchange (ETDEWEB)
In a breeder-type nuclear power plant, liquid metal is used as a coolant due to the high heat capacity factor. Also, some proposals for fusion reactor blanket design include liquid metal as a possible coolant. In both cases the understanding of natural circulation of liquid-metal flow behavior is an integral part of the thermal hydraulic analysis, especially under two-phase flow conditions. Experimental investigations have been conducted to study a liquid metal two-phase natural circulation flow system. A lead-bismuth (PbBi) eutectic mixture is used as a working fluid in a heated metal walled natural circulation loop. Gas injection induces natural circulation through the gas-lift mechanism. A real-time neutron radiography system is used to visualize the two-phase mixture, specifically the interface and the flow regime. Measurements of void fraction, void fluctuation and bubble ...
1996-06-01
International Nuclear Information System (INIS)
In a breeder-type nuclear power plant, liquid metal is used as a coolant due to the high heat capacity factor. Also, some proposals for fusion reactor blanket design include liquid metal as a possible coolant. In both cases the understanding of natural circulation of liquid-metal flow behavior is an integral part of the thermal hydraulic analysis, especially under two-phase flow conditions. Experimental investigations have been conducted to study a liquid metal two-phase natural circulation flow system. A lead-bismuth (PbBi) eutectic mixture is used as a working fluid in a heated metal walled natural circulation loop. Gas injection induces natural circulation through the gas-lift mechanism. A real-time neutron radiography system is used to visualize the two-phase mixture, specifically the interface and the flow regime. Measurements of void fraction, void fluctuation and bubble ...
1996-03-10
Thermomechanical vibration analysis of a functionally graded shell with flowing fluid
Energy Technology Data Exchange (ETDEWEB)
This paper reports the results of an investigation into the vibration of functionally graded cylindrical shells with flowing fluid, embedded in an elastic medium, under mechanical and thermal loads. By considering rotary inertia, the first-order shear deformation theory (FSDT) and the fluid velocity potential, the dynamic equation of functionally graded cylindrical shells with flowing fluid is derived. Here, heat conduction equation along the thickness of the shell is applied to determine the temperature distribution and material properties are assumed to be graded distribution along the thickness direction according to a power-law in terms of the volume fractions of the constituents. The equations of eigenvalue problem are obtained by using a modal expansion method. In numerical examples, effects of material composition, thermal loading, static axial loading, flow velocity, medium stiffness and shell ...
2008-11-15
Mountain scale modeling of transient, coupled gas flow, heat transfer and carbon-14 migration
International Nuclear Information System (INIS)
We simulate mountain-scale coupled heat transfer and gas flow at Yucca Mountain. A coupled rock-gas flow and heat transfer model, TGIF2, is used to simulate mountain-scale two-dimensional transient heat transfer and gas flow. The model is first verified against an analytical solution for the problem of an infinite horizontal layer of fluid heated from below. Our numerical results match very well with the analytical solution. Then, we obtain transient temperature and gas flow distributions inside the mountain. These distributions are used by a transient semianalytical particle tracker to obtain carbon-14 travel times for particles starting at different locations within the repository. Assuming that the repository is filled with 30-year-old waste at an initial areal power density of 57 kw/acre, we find that repository temperatures remain above 60 degrees C for more than 10,000 years. ...
1993-09-26
UARS PEM Level 2 VMAG AC - Mirador - NASA
May 11, 2011 ... The Particle Environment Monitor (PEM) on NASA's Upper Atmosphere Research Satellite (UARS) measures the type, amount, energy, and ...
International Nuclear Information System (INIS)
Sep 1970. 85 p. United States Green, SJ LeTourneau, BW Peterson, AC Bettis
... 041.034.0403 The Morphological Basis of the Armor-Like Folded Skin of the Greater Indian Rhinoceros ... hendo@um.u-tokyo.ac.jp ...
International Nuclear Information System (INIS)
English 1999 p. 47 Brazil Oliveira, JF Braga, ACS Avila, ASR Bernardo-Filho,
1999-10-20
Structure and Characterization of Nicotinic Acetylcholine ...
... the ct-neurotoxin from Dendroaspis viridis venom (a-DTX) , which binds to four sites on the AcChR molecule (Conti-Tronconi & Raftery 1986). ...
1991-11-07
State II Dissociation Element Formation Following Activator Excision in Maize
UK PubMed Central (United Kingdom)
Active Activator (Ac) elements undergo mutations to become nonautonomous Dissociation (Ds) elements at a low frequency. To understand...Full Text Available
2007-10-01
... Advances in Complex Systems ( ACS) 413 (413) 2001-2011 Springer Advances in Data Analysis and Classification 59 (59) 2008-2011 Advances in Management Advances In Management ...
Fish intake and acute coronary syndrome
British Library Electronic Table of Contents (United Kingdom)
Aims To study the effect of fish consumption on the risk of acute coronary syndrome (ACS) in healthy subjects. Methods and results This Danish follow-up study included 57 053 men and women between 50 and 64 years. Intake of lean and fatty fish was estimated from a detailed and validated food frequency questionnaire. Potential cases of ACS were identified through nationwide medical databases. A total of 1122 cases of ACS were verified during a mean follow-up period of 7.6 years. Among men, intake of fatty fish was associated with a lower risk of ACS. For men in the highest quintile of fish intake compared with the lowest quintile, the hazard ratio was 0.67 (95% confidence interval: 0.53-0.85). The inverse association was observed for intakes >6 g of fatty fish per day with no obvious additi...
2010-01-01
International Nuclear Information System (INIS)
English 1998 p. 196 Brazil Oliveira, JF Braga, ACS Santos, JS Bernardo Filho,
1998-05-23
International Nuclear Information System (INIS)
Portuguese 1999 p. 18 Brazil Oliveira, JF Braga, ACS Bezerra, RJAC Bernardo
1999-11-23
British Library Electronic Table of Contents (United Kingdom)
A red basil cell line (T2b) rich in rosmarinic acid (RA) was selected for the stable production of anthocyanins (ACs) in the dark. Cell suspension cultures were subjected to mechanical stress through increased agitation (switch from 90 to 150rpm) to determine the relationship between AC and RA accumulation. Cell extracts were analyzed by HPLC and LC-MS, and the resulting data were processed with multivariate statistical analysis. MS and MS/MS spectra facilitated the putative annotation of several complex cyanidin-based ACs, which were esterified with coumaric acid and, in some cases, also with malonic acid. It was also possible to identify various RA-related molecules, some caffeic and coumaric acid derivatives and some flavanones. Mechanical stress increased the total AC and RA contents, ...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
Two polymeric biosorbents were prepared from cotton stalk (CS) and wheat straw (WS) by the epichlorohydrin-diethylenetriamine-trimethylamine method. Amine-crosslinked cotton stalk (AC-CS) and wheat stalk (AC-WS) were used for the adsorption of phosphate, and their physicochemical properties as well as biosorption properties for phosphate were discussed intensively. Results indicated that the contents of holocellulose in CS and WS corresponded to the distinct phosphate adsorption capacities between AC-CS and AC-WS. Zeta potential and Raman spectra analysis illustrated the electrostatic attraction between phosphate ions and biosorbents. The adsorption of phosphate was not strongly pH dependent when the pH was about 4.0-9.0. The Langmuir isotherm provided the better fit and the maximum adsorp...
2011-01-01
Advisory Committee for GPRA Performance Assessment (AC/GPA) Report FY2003
... impact. The Committee reviewed voluminous materials from NSF?s retrospective and prospective award ...
Influence of two systematic parameters on the geothermal heat pump system operation
Energy Technology Data Exchange (ETDEWEB)
In order to match the output capacity of a geothermal heat pump system (GHPS) with the actual load requirement, research has been carried out in finding the influence of two systematic parameters, the water flow rate inside the condenser and the compressor input frequency on the GHPS operation. Experiments are done on a small-scale GHPS at the water flow rate ranging from 0.054 kg/s to 0.174 kg/s and the frequency from 30 Hz to 55 Hz. The analysis of the experimental data reveals the relationships among the compressor frequency, the water flow rate and other important parameters such as coefficient of performance (COP), heat capacity and compressor power input. The conclusions in the paper can serve as some guidance to the load adjustment of GHPS. (author)
2003-01-01
Critical current density and dissipation in sintered YBCO filaments
Energy Technology Data Exchange (ETDEWEB)
Critical current density and dissipation of four sintered YBCO filaments were measured using a continuous DC power supply. Each sample exhibited somewhat different characteristics from the others even though 3 of the 4 samples are from the same batch. The data suggest that it is possible for the YBCO filament to be in a state of stable equilibrium when part of the filament is in the flux-flow state and part of the filament is in the normal state (local hot spots). This behavior may be advantageous for resistive fault current limiters because the intermediate state (partly flux-flow and partly normal) has an overall resistance much higher than that of the flux-flow state but it does not lead to thermal runaway (burnout) or excessive heating compared to a YBCO filament driven into normal state over its entire length. Two of the samples were broken as a result of local burnout.
1997-09-01
Energy Technology Data Exchange (ETDEWEB)
This comprehensive final report for the Swiss Federal Office of Energy (SFOE) examines ways to optimise energy flows in mains networks that include distributed generation facilities. Increasing use of decentralised generation, its effects on the operation of low-voltage mains and the efficient use of the 400 V mains is discussed. The principles of operation and construction of controlled storage installations are discussed and concrete examples of their use in both grid-connected and island operation are quoted. Alternatives to storage are looked at from both the technical and economic points of view. The storage technologies used such as flywheels, supercaps, redox-flow batteries and lead-acid accumulators are briefly assessed and the results of simulations are discussed.
2005-07-01
International Nuclear Information System (INIS)
Purpose: To flatten temperature distribution of coolant within a core. Constitution: The control device of the present invention is to vary reactivity of a fast breeder to control a reactor power. In general, the control device of this kind comprises a guide pipe arranged within the core and a control rod movable up and down within the guide pipe, and a coolant flows from bottom toward top within the guide pipe. Since a cooling flow rate has a margin, temperature of coolant outlet is extremely low as compared to a fuel assembly, and therefore temperature gradient in the vicinity of the top of the control rod becomes sharp to possibly impart thermal shock to the structural material. In the present invention, the flow passage of coolant is varied to thereby avoid outflow thereof into the core, thus flattening the temperature distribution of the coolant within the core. (Kamimura, M.).
Application of multi-fluid model in dryout prediction
International Nuclear Information System (INIS)
Dryout predictions using a multi-flood model for the annular two-phase flow regime are compared against dryout data obtained for BWR condition. The multifluid model treats two-phase flow as composed of distinct fluid regions (fluids) and individual conservation equations are applied to each fluid. Dryout is assumed to occur when flow rate of one of the liquid films becomes zero. The factor is extended to cover dryout data for very short boiling lengths. The present study involves wide ranges in geometries, heat flux distributions, and fluid concentrations. The accuracy of dryout power prediction is found to be as good as that of empirical correlations. It is confirmed that within a single analytical framework, the model can handle various classes of dryout analyses whereas the existing equilibrium models cannot.
1983-01-01
Loop frame of reference based three-phase power flow for unbalanced radial distribution systems
Energy Technology Data Exchange (ETDEWEB)
This paper introduces a novel three-phase power flow approach for unbalanced radial distribution systems. The proposed approach is developed based on the loop frame of reference, rather than the traditional bus frame of reference. On the basis of the loop frame of reference, a simple direct iterative method in impedance form is applied. Basic graph theory and injection current technique are also applied in the proposed approach. The clear theoretical foundation and the simple topology of the radial distribution network make the proposed method efficient and reliable. To demonstrate the better convergence performance and the efficiency of the proposed approach, four three-phase IEEE test feeders are used for comparisons. The test results show that the proposed method has robust convergence characteristics and high performance, especially for large-scale radial distribution systems. (author)
2010-07-15
The central engine of Gamma Ray Bursts is hidden from direct probing with photons mainly due to the high densities involved. Inferences on their properties are thus made from their cosmological setting, energetics, low-energy counterparts and variability. If GRBs are powered by hypercritical accretion onto compact objects, on small spatial scales the flow will exhibit fluctuations, which could in principle be reflected in the power output of the central engine and ultimately in the high energy prompt emission. Here we address this issue by characterizing the variability in neutrino cooled accretion flows through local shearing box simulations with magnetic fields, and then convolving them on a global scale with large scale dynamical simulations of accretion disks. The resulting signature is characteristic, and sensitive to the details of the cooling mechanism, providing in principle a discriminant for ...
2010-01-01
An innovative method of providing total breaker failure protection
Energy Technology Data Exchange (ETDEWEB)
Breaker failure relaying has been generally achieved through the use of a current monitoring relay to determine whether current continues to flow into a fault after a breaker has been instructed to interrupt the circuit. If current continues to flow after a predefined period of time, the circuit breaker is considered to have failed. Steps must then be taken to trip the next set of upstream breakers in the power system to remove the faulted circuit and prevent system damage. However, with industrial power systems, this may be the utility`s breakers on the feeding transmission line. Regardless, breaker failure schemes must be designed to isolate both the faulted circuit and the failed circuit breaker. This paper discusses a new and innovative method of protecting a circuit breaker from the failure described above, plus other failures that go unprotected with conventional schemes, this providing total ...
1996-09-01
Validation studies of thermal-hydraulic code for safety analysis of nuclear power plants
Energy Technology Data Exchange (ETDEWEB)
The thesis gives an overview of the validation process for thermal-hydraulic system codes and it presents in more detail the assessment and validation of the French code CATHARE for VVER calculations. Three assessment cases are presented: loop seal clearing, core reflooding and flow in a horizontal steam generator. The experience gained during these assessment and validation calculations has been used to analyze the behavior of the horizontal steam generator and the natural circulation in the geometry of the Loviisa nuclear power plant. Large part of the work has been performed in cooperation with the CATHARE-team in Grenoble, France. (41 refs., 11 figs., 8 tabs.).
1995-12-31
International Nuclear Information System (INIS)
The major feed-water line break accident is re-analyzed, which is based on Guangdong Daya Bay nuclear power station final safety analysis report, to justify the impacts of the decreasing of auxiliary feed-water flow rate on the safety margin in Daya Bay. The results showed that the accident analysis can meet the demands of acceptance criteria with the auxiliary feed-water flowrate decreasing from 45 m"3/h to 41.8 m"3/h, and enough safety margin is still retained
2002-06-01
Dynamics and developing of natural circulation cooling from vertical upflow and downflow conditions
International Nuclear Information System (INIS)
Several research programs have been conducted to evaluate the capability of natural circulation cooling of reactors following a loss of cooling accident. Both experimental and RELAP5 simulation results were obtained for these studies in a facility with vertical heated tube(s) and a unheated bypass channel. The analytical results showed that, under a certain power level, a natural circulation pattern can be developed from both initial upflow and downflow conditions, and maintained for a significant cooling period. This power level, for the discussion of this paper, is defined as the natural circulation cooling (NCC) power limit. Two import factors, namely the pump coastdown rate and the initial flow direction, are examined in this paper. In the benchmark case, as compared to the experimental results, the RELAP5 simulation program accurately predicted the transient phenomena from forced convection through ...
1994-04-05
International Nuclear Information System (INIS)
Based on the occurrence of a number of plant incidents during low power and shutdown operating conditions, the Nuclear Regulatory Commission (NRC) has initiated several programs to better quantify risk during these periods. One specific issue of interest is the loss of residual heat removal (RHR) under reduced coolant inventory conditions. This issue is also of interest in the Federal Republic of Germany and an experiment was performed in the integral PKL-3 experimental facility at Siemens-KWU to supply applicable data. Recently, an effort has been undertaken at the Idaho National Engineering Laboratory (INEL) to identify and analyze the important thermal-hydraulic phenomena in pressurized water reactors following loss of vital AC power and consequent loss of the RHR system during reduced inventory operation. The thermal-hydraulic response of a nuclear steam supply system (NSSS) with a closed reactor coolant system (RCS) to ...
1991-10-01
Horizontal Steam Generator Thermal-Hydraulics at Various Steady-State Power Levels
Three-dimensional computer simulation and analyses of the horizontal steam generator thermal-hydraulics of the WWER 1000 nuclear power plant have been performed for 50% and 75% partial loads, 100% nominal load and 110% over-load. Presented results show water and steam mass flow rate vectors, steam void fraction spatial distribution, recirculation zones, swell level position, water mass inventory on the shell side, and other important thermal-hydraulic parameters. The simulations have been performed with the computer code 3D ANA, based on the 'two-fluid' model approach. Steam-water interface transport processes, as well as tube bundle flow resistance, energy transfer, and steam generation within tube bundles are modelled with {sup c}losure laws{sup .} Applied approach implies non-equilibrium thermal and flow conditions. The model is solved by the control volume procedure, which has been ...
2002-07-01
Horizontal Steam Generator Thermal-Hydraulics at Various Steady-State Power Levels
International Nuclear Information System (INIS)
Three-dimensional computer simulation and analyses of the horizontal steam generator thermal-hydraulics of the WWER 1000 nuclear power plant have been performed for 50% and 75% partial loads, 100% nominal load and 110% over-load. Presented results show water and steam mass flow rate vectors, steam void fraction spatial distribution, recirculation zones, swell level position, water mass inventory on the shell side, and other important thermal-hydraulic parameters. The simulations have been performed with the computer code 3D ANA, based on the 'two-fluid' model approach. Steam-water interface transport processes, as well as tube bundle flow resistance, energy transfer, and steam generation within tube bundles are modelled with "closure laws". Applied approach implies non-equilibrium thermal and flow conditions. The model is solved by the control volume procedure, which has been extended in order to take ...
2002-04-14
Energy Technology Data Exchange (ETDEWEB)
A study was made for the purpose of electrification of unelectrified zones of the mountainous areas in developing countries using extremely small hydroelectric power facilities. The target for this project is a development of a micro hydroelectric power system with a size of about 5kW, which is estimated regarding that 1 village has 80 houses and each house needs electricity of 60W. In the study, the low-head system using a weir of irrigation channels in Subang pref. of West Java state was selected by the evaluation of access, stability of flow rate, natural conditions, etc. The hydroelectric power plant is of a flow-in method in which water is taken from the left bank and is injected/discharged to the downstream of the left bank. As the hybrid complementary power source, hybrid battery with a two-hour charging time at peak and a capacity of 3.5kWh was ...
1996-03-01
Energy Technology Data Exchange (ETDEWEB)
Since 1985 the operating sections of the 1200 kV AC Ekibastuz-Urals transmission system were used for a variety of field studies on a wide range of technological problems associated to high voltage transmission lines. The tests performed confirmed correctness of the main engineering and design decision made at development stage and demonstrated that such transmission lines are reliable and efficient. 3 figs.
1989-12-31
UK PubMed Central (United Kingdom)
Long-term heat acclimation (AC, 30d/34°C) is a phenotypic adaptation leading to increased thermotolerance during heat stress (HS, 2 h 41°C). AC also renders protection against...Full Text Available
2010-09-01
International Nuclear Information System (INIS)
We have previously shown that budded viruses of Bombyx mori nucleopolyhedrovirus (BmNPV) enter the cell cytoplasm but do not migrate into the nuclei of non-permissive Sf9 cells that support a high titer of Autographa californica multicapsid nucleopolyhedrovirus (AcMNPV) multiplication. Here we show, using the syncytium formation assay, that low-pH-triggered membrane fusion of BmNPV GP64 protein (Bm-GP64) is significantly lower than that of AcMNPV GP64 protein (Ac-GP64). Mutational analyses of GP64 proteins revealed that a single amino acid substitution between Ac-GP64 H155 and Bm-GP64 Y153 can have significant positive or negative effects on membrane fusion activity. Studies using bacmid-based GP64 recombinant AcMNPV harboring point-mutated ac-gp64 and bm-gp64 genes showed that Ac-GP64 H155Y and Bm-GP64 Y153H substitutions decreased and ...
2010-09-01
The main steam piping of nuclear power plant which runs between steam generator and high pressure turbine has been experienced to have a severe effect on the safe operation of the plant due to the vibration induced by the steam flowing inside the piping. ...
1996-01-01
Feasibility of maintaining natural convection mode core cooling in research reactor power upgrades
International Nuclear Information System (INIS)
Two operational concerns for natural convection coooled research reactors using plate type fuels are: 1) pool top "1"6N activity (PTNA), and 2) nucleate boiling in core channels. The feasibility assessment of a power upgrade while maintaining natural convection mode core cooling requires addressing these operational concerns. Previous studies have shown that: a) The conventional technique for reducing PTNA by plume dispersion may not be effective in a large power upgrade of research reactors with small pools. b) Currently used correlations to predict onset of nucleate boiling (ONB) in thin, rectangular core channels are not valid for low-velocity, upward flows such as encountered in natural convection cooling. The PTNA depends on the velocity distribution in the reactor pool. COMMIX-1A code is used to determine the three-dimensional velocity fields in The Ohio State University Research Reactor (OSURR) pool as a function of ...
1988-05-01
Continuous emission monitoring -- Data acquisition and handling system for management
Energy Technology Data Exchange (ETDEWEB)
This paper describes New York State Electric and Gas Corporation`s concept for a comprehensive, centrally located data system for management of their continuous emission monitoring systems (CEMS) data. The topics of the paper include the power system`s mix of generating units; data reporting requirements; data base management; nitrogen oxides compliance tracking; sulfur dioxide, nitrogen oxides, carbon dioxide and flow monitoring; and allowance tracking.
1995-09-01
Generalized simulation model for reservoir system analysis. Technical paper
Energy Technology Data Exchange (ETDEWEB)
This paper overviews the general features of computer program 'HEC-5, Simulation of Flood Control and Conservation Systems', with emphasis on the capabilities of the most recent release of HEC-5, Version 7.2, dated March 1991. HEC-5 can simulate the essential features and operation goals and constraints of simple or complex systems with simulation intervals ranging from minutes to one month. Single event flood analysis and period of record conservation analysis may be accomplished with the model. Flood control analysis includes balanced system operation for downstream damage centers with consideration of forecasted local flows and hydrologic routing. In addition, induced surcharge operation based on spillway gate regulation schedules can be simulated. Hydropower analysis may include run-of-river, peaking, and pumped storage plants as well as system power operation. Water supply simulation can include reservoir and downstream ...
1992-03-01
Remedial action selection report Maybell, Colorado, site. Final report
Energy Technology Data Exchange (ETDEWEB)
The Maybell uranium mill tailings site is 25 miles (mi) (40 kilometers [km]) west of the town of Craig, Colorado, in Moffat County, in the northwestern part of the state. The unincorporated town of Maybell is 5 road mi (8 km) southwest of the site. The site is 2.5 mi (4 km) northeast of the Yampa River on relatively flat terrain broken by low, flat-topped mesas. U.S. Highway 40 runs east-west 2 mi (3.2 km) south of the site. The designated site covers approximately 110 acres (ac) (45 hectares [ha]) and consists of a concave-shaped tailings pile and rubble from the demolition of the mill buildings buried in the former mill area. The site is situated between Johnson Wash to the east and Rob Pit Mine to the west. Numerous reclaimed and unreclaimed mines are in the immediate vicinity. Aerial photographs (included at the end of this executive summary) show evidence of mining activity around the Maybell site. Contaminated materials at the Maybell processing site include ...
1996-12-01
Energy Technology Data Exchange (ETDEWEB)
The Maybell uranium mill tailings site is 25 miles (mi) (40 kilometers [km]) west of the town of Craig, Colorado, in Moffat County, in the northwestern part of the state. The unincorporated town of Maybell is 5 road mi (8 km) southwest of the site. The designated site covers approximately 110 acres (ac) (45 hectares [ha]) and consists of a concave-shaped tailings pile and rubble from the demolition of the mill buildings buried in the former mill area. Contaminated materials at the Maybell processing site include the tailings pile, which has an average depth of 20 feet (ft) (6 meters [m]) and contains 2.8 million cubic yards (yd{sup 3}) (2.1 million cubic meters [m{sup 3}]) of tailings. The former mill processing area is on the north side of the site and contains 20,000 yd{sup 3} (15,000 m{sup 3}) of contaminated demolition debris. Off-pile contamination is present and includes areas adjacent to the tailings pile, as well as contamination dispersed by wind and ...
1994-06-01
Energy Technology Data Exchange (ETDEWEB)
The fixed bed pilot plant, the catalyst testing procedure, and the calculations for conversion and selectivities were previously described in the technical progress report covering the period of 3/16/88 to 6/16/88 for Contract DE-AC22-87PC79812. Conversions and hydrocarbon selectivities were calculated using data from an on-line gas chromatography (GC) analyzer. Alcohol selectivities were calculated using data from an on-line boiling point GC analyzer which analyzed the liquid product. The catalysts were prepared via the steps of impregnation, calcination, and reduction on a special Y-zeolite-derived support. The impregnation step consisted of evaporation of metal salts on to the support from an aqueous solution. For one catalyst (No. 6531-188) the metal salts were evaporated on to the support from a reverse micelle solution containing the metal salts. All the catalysts were calcined for four hours at 450{degree}C. The calcined catalysts were loaded in the reactor ...
1992-12-31
Energy Technology Data Exchange (ETDEWEB)
This article gives an account of the recent development of light water reactors new concepts in the world. Different projects are being studied. The CE80+ from Combustion Engineering (CE) is a 1350 MWe-PWR-type reactor whose primary circuit is confined in a spherical metallic containment. This reactor was certified by NRC (national regulatory commission) in mid-1996. The APWR (advanced pressurized water reactor) is developed by MHI (Mitsubishi heavy industries) in a collaboration with Westinghouse, this PWR-type reactor fitted with 4 loops derived from the SP90 model that was developed by Westinghouse during the eighties. 2 units of ABWR (advanced boiling water reactor) were commissioned in Japan in 1996 and 1997, ABWR was certified by NRC in mid-1996. The BWR90+ is developed by ABB-atom (Sweden) and it represents a cautious advanced version of the BWR75. Passive reactors are reactors that rely only on potential energy (compressed gas, gravitational flow or ...
2001-07-01
Energy Technology Data Exchange (ETDEWEB)
Due to its important hydroelectric power generation facilities (about 525 plants with a total power of 13,314 MW producing about 35.3 TWh annually) Switzerland plays an important role in the interconnected European power system. Large artificial storage lakes in the Swiss Alps can generate peak power during hours of highest demand: 9700 MW are available from accumulated energy and the total power of pumped-storage facilities amounts to 1700 MW. The latter allow refilling the reservoirs at periods of low power demand and generating power at periods of peak demand. In the case of favorable conditions, the yearly average power production could be increased by 6% and the production during the winter period (October to March) by 20% by the year 2020. However, looking forward to the year 2050, the annual production is expected ...
2007-07-01
British Library Electronic Table of Contents (United Kingdom)
This research aims to investigate the effects of chemical blowing agent (CBA) contents and particle sizes on the properties of foamed poly(vinyl chloride) (PVC)/rice hull (RH) composites. Fine particles of azodicarbonamide (AC) at 5, 8, 11 and 22mm were modified with 20% by weight of ZnO and used at 0-3.0% by weight. The average cell size and density of the PVC/RH foamed profiles were reduced as the content of modified azodicarbonamide (mAC) increased. Larger mAC particles lowered the density more effectively. Maximum reduction of density by 46% was achieved when mAC 22mm was applied at 2.0% by weight. Larger blowing particles led to PVC/RH foam with greater flexural modulus and strength. Greater impact strength, observed when 5mm mAC was applied, resulted from the rather thick cell wall c...
2011-01-01
Loss of flow incident - Simulation and measurements in the MPR
International Nuclear Information System (INIS)
As part of the Probabilistic Safety Analysis of the Multi Purpose Reactor, MPR, the list of Postulated Initiating Events was analyzed and one of these PIEs corresponds to the Loss of Coolant Flow. It is well known that during the operation life of a research reactor a LOFA could eventually occur and, once this event takes place, in time detection and automatic actions, thanks to the engineering safety features of the system, will mitigate the incident evolution. The postulated event corresponds to a loss of flow due to a total loss of power supply. The goal of the present work is to provide a general description and the engineering safety features of the MPR, as well as describe the sequence of scenarios during a LOFA. Temporal evolution of main parameters is presented, also. During Stage A of the Commissioning Program measurements of the core cooling system pump coast-down were performed in order to validate previous ...
1999-10-26
Flow induced vibration mock-up test for heat exchanger tubes of PWR steam generator
International Nuclear Information System (INIS)
It is one of the most important subjects to estimate the flow-related stability of the heat exchanger tubes. A large scale model steam generator has been developed to verify the stability of the tubes in the Japanese PWR steam generators for the two-phase flow-induced vibration and to accumulate related technical data of thermal-hydraulic and flow-induced vibration of U-bend tube bundle. The model steam generator has 230 U-bend tubes of 46 different radius and 5 columns for each of practical diameter and material, and the anti vibration bars are inserted into each spacing between tube arrays. The freon R123 has been used as the secondary side fluid in stead of water-steam two-phase. In the test, void fraction and interfacial velocities in U-bend and straight tube-bundle are measured with bi-optical probes, and vibration responses of some selected tubes are measured with strain gauges and accelerators. It is verified that ...
2000-10-01
Energy Technology Data Exchange (ETDEWEB)
The effect of transverse magnetic field parameter (Hartmann number, Ha) Reynolds number (Re) and Prandtl number (Pr) on the mixed convection flow past a semi-infinite vertical porous plate in a non-Darcian porous medium with variable viscosity and porosity, viscous dissipation and fluid-solid thermal conductivity ratio in the presence of plate transpiration (lateral mass flux) is investigated theoretically and numerically using Keller`s implicit finite difference scheme. It is shown that the Harmann number acts as a retarding force and increases the momentum boundary layer thickness, analogous to the flow against a positive pressure gradient, simultaneously decreasing local skin friction (shear stress). The heat transfer rate is however enhanced by the magnetic field (for positive values of the Eckert number) since the fluid is heated and temperature gradients become reduced between the fluid and the plate, with important potential applications ...
1997-01-01
A study of turbulent heat transfer in the subchannel by the large scale secondary vortex flow
International Nuclear Information System (INIS)
Experimental and computational studies were performed to confirm the enhancement of turbulent heat transfer performance in the 6x6 simulated rod bundle subchannel by generating the large scale secondary vortex flow. Experimental studies were carried out at Reynolds Number 10,000 with atmospheric condition. Axial variations of mean velocity and turbulent intensity in the rod bundle subchannel were measured by the 2-color LDV measurement system. Computational works were accomplished using the commercial CFD code, FLUENT. Normal operating condition of Uljin 3, 4 nuclear power plant is used in computation works as an initial condition. The LSSVF mixing vanes generate the most strong secondary flow vortices that maintain about 35 D_H after the spacer grid. The LSSVF mixing vane influences strongly to flow mixing in adjacent subchannels because large scale stream wise vortices in subchannel sustain two times ...
2002-11-17
Modernizing steam turbines for nuclear power plants
International Nuclear Information System (INIS)
Economic and safe operation of nuclear power plants requires reliable steam turbines with high efficiencies. The progress in flow mechanics achieved over the past few years has allowed the use of powerful methods of flow calculation in developments of new blading with greatly enhanced efficiencies. Thanks to the latest manufacturing techniques, the newly developed blading systems can be produced at low cost. Next to progress in flow mechanics, also the broadbased use of advanced finite-element calculations resulted in a more thorough grasp of the many problems associated with structural mechanics assessment of steam turbine components. The theoretical methods have been supplemented by comprehensive efforts in fracture mechanics and experimental materials studies, thus helping to create a reliable knowledge base which will help to avoid the dreaded stress corrosion cracking ...
Power-cycle studies for a geothermal electric plant for MX operating bases
Energy Technology Data Exchange (ETDEWEB)
Binary geothermal plants were investigated for providing electrical power for MX missile bases. A number of pure hydrocarbons and hydrocarbon mixtures were evaluated as working fluids for geothermal resource temperatures of 365, 400, and 450/sup 0/F. Cycle thermodynamic analyses were conducted for pure geothermal plants and for two types of coal-geothermal hybrid plants. Cycle performance results were presented as net geofluid effectiveness (net plant output in watts per geofluid flow in 1 bm/hr) and cooling water makeup effectiveness (net plant output in watts per makeup water flow in 1 bm/hr). A working fluid containing 90% (mass) isobutane/10% hexane was selected, and plant statepoints and energy balances were determined for 20MW(e) geothermal plants at each of the three resource temperatures. Working fluid heaters and condensers were sized for these plants. It is concluded that for the advanced plants investigated, ...
1981-11-01
Hydrodynamic and thermal modeling of solid particles in a multi-phase, multi-component flow. [LMFBR
Energy Technology Data Exchange (ETDEWEB)
This paper presents the new thermal hydraulic models describing the hydrodynamics of the solid fuel/steel chunks during an LMFBR hypothetical core-disruptive accident. These models, which account for two-way coupling between the solid and fluid phases, describe the mass, momentum, and energy exchanges which occur when the chunks are present at any axial location. They have been incorporated in LEVITATE, a code for the analysis of fuel and cladding dynamics under Loss-of-Flow (LOF) conditions. Their influence on fuel motion is presented in the context of the L6 TREAT experiment analysis. It is shown that the overall hydrodynamic behavior of the molten fuel and solid-fuel chunks is dependent on both the size of the chunks and the power level. At low and intermediate power levels the fuel motion is more dispersive when small chunks, rather than large ones, are present. At high power levels the situation is ...
1983-01-01
Low power cross-flow atmospheric pressure Ar + He plasma jet
International Nuclear Information System (INIS)
A cross-flow atmospheric plasma jet with distilled water or analyte solution nebulization has been investigated. The plasma gas flows perpendicularly to the RF powered electrode (11.21 MHz) and a grounded electrode was added for plasma stabilization. The working parameters of the plasma generator can be controlled in order to maximize either the plasma power (75 W) or the voltage on the RF powered electrode (plasma power, 40 W). The plasma gas, pure argon (0.4 l min-1) or a mixture of argon (0.3-0.4 l min-1) and helium (0-0.2 l min-1), was also used for liquid nebulization. Optical emission of the plasma, collected in the normal viewing mode, was used for plasma diagnostics and for evaluating its excitation capabilities. The influence of helium content in the mixed-gas plasma on the plasma characteristics and on the emission axial profiles of the plasma gas ...
2010-04-01
Micro gas turbine operation with biomass producer gas
Energy Technology Data Exchange (ETDEWEB)
We report the performance of a micro gas turbine on biomass producer gas and mixtures of biomass producer gas with natural gas. The micro gas turbine delivers full power on gas mixtures with a heating value of at least 15 MJ/Nm{sup 3}. For gas of lower heating value, the maximum fuel gas flow limits the attainable power. The lower limit for stable operation is about 8 MJ/Nm{sup 3}. The gross efficiency of the micro gas turbine depends on output power but not on the gas heating value, within our measurement accuracy. Above 70% of full power, emissions of CO and NO are 40 and 10 times lower than those of a gas engine of similar size. At part load below 70% of full power, the micro gas turbine burner switches to a different operating mode which produces higher CO and NO levels, but still significantly below those of a gas engine.
2007-08-15
Summary.? Measuring von Willebrand factor (VWF) activity is essential to the diagnosis of von Willebrand disease (VWD). The VWF activity is usually assessed based on measurement of the ristocetin cofactor (VWF:RCo). However, that test is technically challenging and has high intra- and inter-assay variabilities. The HemosIL VWF activity (VWF:AC) is a fully automated assay, recently proposed as a good alternative to VWF:RCo for VWD diagnosis. This study was undertaken to assess this new method. First, the analytical performance of VWF:AC on an automated coagulo-meter (ACLTop) was determined, and then this new method was compared with VWF:RCo and the platelet function analyzer (PFA100) for 160 patients referred for VWD screening. The VWF:AC achieved acceptable precision with within-run and between-run coefficients of variation ranging from 2.3% to 14.1%, and linearity from 10% to 100%. Despite some marked differences between ...
2011-09-28
Modification of adenylate cyclase by photoaffinity analogs of forskolin
Energy Technology Data Exchange (ETDEWEB)
Photoaffinity labeling analogs of the adenylate cyclase activator forskolin (PF) have been synthesized, purified and tested for their effect on preparations of membrane-bound, Lubrol solubilized and forskolin affinity-purified adenylate cyclase (AC). All analogs of forskolin significantly activated AC. However, in the presence of 0.1 to 0.3 microM forskolin, the less active forskolin photoaffinity probes at 100 microM caused inhibition. This inhibition was dose-dependent for PF, suggesting that PF may complete with F for the same binding site(s). After cross-linking (125I)PF-M to either membrane or Lubrol-solubilized AC preparations by photolysis, a radiolabeled 100-110 kDa protein band was observed after autoradiography following SDS-PAGE. F at 100 microM blocked the photoradiolabeling of this protein. Radioiodination of forskolin-affinity purified AC showed several protein bands on autoradiogram, ...
1989-01-01
Numerical simulation of progressive inlet orifices in boiling water reactor fuel
International Nuclear Information System (INIS)
This thesis was carried out at Forsmark Nuclear Power Plant. The power plant in Forsmark consists of three boiling water reactors (BWR) which produce about 17% of Swedish electricity. In a BWR the nuclear reactions are used to boil water inside the reactor vessel. The water works both as a coolant and as a moderator and the resulting steam is used directly to run the turbines. A problem when running a BWR at low flow conditions is the density wave oscillations that might occur to the water flow inside the fuel assemblies. These oscillations arise due to the connection between power and flow rate in a heated channel with two-phase flow. In order to improve the stability performance of the channel an orifice plate is placed at the inlet of each fuel assembly. Today these orifice plates have sharp edges and a constant resistance coefficient. ...
2004-01-01
International Nuclear Information System (INIS)
The radio, optical, x-ray and gamma-ray nebulae that surround many pulsars are thought to arise from synchrotron and inverse Compton emission. The energy powering this emission as well as the magnetic fields and relativistic particles are supplied by a 'wind' driven by the central object. The inner parts of the wind can be described using the equations of MHD, but these break down in the outer parts, when the density of charge carriers drops below a critical value. This paper reviews the wave properties of the inner part (striped wind), and uses a relativistic two-fluid model (cold electrons and positrons) to re-examine the nonlinear electromagnetic modes that propagate in the outer parts. It is shown that in a radial wind, two solutions exist for circularly polarized electromagnetic modes. At large distances one of them turns into a freely expanding flow containing a vacuum wave, whereas the other decelerates, corresponding to a confined ...
2010-12-01
Thermal performance simulation of a solar cavity receiver under windy conditions
British Library Electronic Table of Contents (United Kingdom)
Solar cavity receiver plays a dominant role in the light-heat conversion. Its performance can directly affect the efficiency of the whole power generation system. A combined calculation method for evaluating the thermal performance of the solar cavity receiver is raised in this paper. This method couples the Monte-Carlo method, the correlations of the flow boiling heat transfer, and the calculation of air flow field. And this method can ultimately figure out the surface heat flux inside the cavity, the wall temperature of the boiling tubes, and the heat loss of the solar receiver with an iterative solution. With this method, the thermal performance of a solar cavity receiver, a saturated steam receiver, is simulated under different wind environments. The highest wall temperature of the boi...
2011-01-01
Thermal hydraulic analysis of nuclear reactors (THEA). THEA summary report
Energy Technology Data Exchange (ETDEWEB)
The project is focused on the thermal hydraulic analyses of nuclear power plants. Specific areas of research have been the modelling of heat transfer in horizontal steam generator in presence of non-condensable gas, and the development of tools for multidimensional two-phase flow simulations. The effect of non-condensable gas on the heat transfer in the horizontal steam generator (SG) has been studied by calculating with APROS the PACTEL experiments NCG-1 (air injection) and NCG-3 (helium injection). The work done for the two-phase flow model development consists of two parts; improving the solution algorithm of porous media code PORFLO, and adding a homogeneous two-phase model to the commercial CFD code Fluent. (orig.)
2004-07-01
Safety analysis of FFTF loss of flow without scram tests
International Nuclear Information System (INIS)
A program of tests were conducted in July 1986 at the Fast Flux Test Facility (FFTF) to demonstrate that the reactor could withstand a prototypic loss of flow (LOF) without scram without sustaining fuel damage. The reactor was taken to powers up to 50%, and the main primary coolant pump motors were tripped without scramming the control rods. This paper summarizes the analyses performed to demonstrate the maintenance of redundant protection for all design events as well as potential new events introduced by the test. The analyses focused on the following consequences: (1) unexpected test behavior; (2) transient overpower event during the test; and (3) LOF event during the test.
1987-06-07
Energy Technology Data Exchange (ETDEWEB)
Because power requirements in induction heating applications are largely dependent on the physical properties of the product to be heated, inducting, heating is mainly used in steelwork applications, for the manufacture of finished or semi-finished parts. Applications here cover five main types of steelworks operation: smelting, heating prior to forming, heat treatment, surface treatment, and assembly process. At the same time, technological progress has opened up innovative applications in sectors such as chemical and agro-food industries. Other emerging applications for induction include direct forming of liquid metal, wholly or partially replacing mechanical transformations on solid metal. Techniques include electromagnetic forming, continuous cold-crucible casting, electromagnetic mixing, flow control by continuous magnetic field, and production of intense sliding fields (pumps, flow regulation). (author)
2004-05-01
Numerical methods for thermal-hydraulics and structure in nuclear engineering
International Nuclear Information System (INIS)
Designs of nuclear reactor plants aim for high performance under safety consideration. Because of large scale and high pressure/temperature conditions, data from costly mockup tests have been required to verify simulation codes of systems and components. Establishment of design by analysis (DBA) in nuclear engineering is required for development of next generation nuclear reactors. Recent powerful computers and simulation technique enable numerical analyses to predict realistic behaviors of thermo-fluid flow, structure and do on. The present report describes resent simulation results of complex gas-liquid two-phase flow, large scale structure dynamics and fluid-structure interaction. (author)
2008-06-01
Multifractal Fourier detrended cross-correlation analysis of traffic signals
Multifractal detrended cross-correlation analysis (MF-DXA) has been developed to detect the long-range power-law cross-correlation of considered signals in the presence of non-stationarity. However, crossovers arising from extrinsic periodic trends make the scaling behavior difficult to analyze. We introduce a Fourier filtering method to eliminate the trend effects and systematically investigate the multifractal cross-correlation of simulated and real traffic signals. The crossover locations are found approximately corresponding to the periods of underlying trend. Traffic velocity on one road and flows on adjacent roads show strong cross-correlation. They also present weak multifractality after periodic trends are removed. The traffic velocity and flow are cross-correlated in opposite directions which is accordant to their actual evolution.
2011-10-01
Linearization of Valve Flow Characteristics for Steam Turbine Control
Energy Technology Data Exchange (ETDEWEB)
The control valve for a large steam turbine must be operated linearly to be run by an automatic control system in a power plant. It is, however, found that the flow increase is much greater for a given valve position change near the closed end of travel than it is near the open end. Accordingly, the desired linearization will be achieved if the valve is opened less near the closed end of travel and greater near the open end. The previous way for linearization was to utilize the cams, which is called the mechanical hydraulic control (MHC). The MHC was afterward improved by producing the nonlinear electric compensation to the nonlinear system of control valves, viz. the electro hydraulic control (EHC). This paper addresses the principle of linearization.
2009-05-15
Linearization of Valve Flow Characteristics for Steam Turbine Control
International Nuclear Information System (INIS)
The control valve for a large steam turbine must be operated linearly to be run by an automatic control system in a power plant. It is, however, found that the flow increase is much greater for a given valve position change near the closed end of travel than it is near the open end. Accordingly, the desired linearization will be achieved if the valve is opened less near the closed end of travel and greater near the open end. The previous way for linearization was to utilize the cams, which is called the mechanical hydraulic control (MHC). The MHC was afterward improved by producing the nonlinear electric compensation to the nonlinear system of control valves, viz. the electro hydraulic control (EHC). This paper addresses the principle of linearization.
2009-05-01
Heat transfer augmentation in an axisymmetric impinging jet
This paper presents the experimental results of heat transfer augmentation in an axisymmetric jet impinging normally on a flat plate surface without the requirement of additional pumping power. The present technique of augmentation utilizes only a punched plate with circular holes arranged in a triangular array, fixed parallel to, just in front of the heated target plate. Near the optimum conditions determined, the heat transfer coefficient at the geometrical stagnation point can be increased 4 times. Additional flow visualization study indicates that this augmentation mechanism creates an improved flow field where the punched plate acts as a detached fin, the conductivity of which may be exploited for further augmentation. Besides augmentation, the present investigation foresees the possibility of manipulating the distribution of local heat transfer rate by varying few parameters.
1982-01-01
Electrohydrodynamic pumping in cable pipes. Final report
Energy Technology Data Exchange (ETDEWEB)
Many oil-insulated electric power cables are limited by heat buildup caused in part by the low thermal conductivity of the oil. Circulation of the oil is known to reduce the cable temperature, but can lead to excessive pressure buildup on long cables when using conventional pumping methods. An alternate pumping method using distributed electric fields to avoid this pressure buildup is described. Electrohydrodynamic (EHD) pumping was studied both theoretically and experimentally for possible application in underground cable cooling. Theoretical studies included both analytical and finite-element analysis of the flow patterns driven by travelling electric fields. Experimentally, flow rates in a cable-pipe model were measured under a wide variety of operating conditions. Theory and experiment are in agreement for velocities below 10 cm/s, but higher velocities could not be reached in the experiment, due to increased ...
1983-02-01
British Library Electronic Table of Contents (United Kingdom)
Abstract Characteristics of batch rotor-stator mixer performance are elucidated by shaft torque and angle resolved 2D PIV measurements obtained in a full-scale, custom build, bottom-mounted, rotor-stator mixer unit operating in the turbulent regime with water as working fluid. Measurements have been acquired at various rotor speeds corresponding to impeller based Reynolds numbers between 2.0--105 and 8.5--105. The use of a transparent Plexiglas stator facilitated PIV measurements inside and outside the stator as well as into the stator slots themselves. The governing mechanisms controlling the complex flow structures, flow rates, power dissipation, velocity fields, strain rate fields and turbulence intensity fields are explained, highlighting the influence on rotor-stator mixer performance...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
The need to increase efficiency of volumetric receivers for use in solar power plants by reducing reradiation losses and increasing the ``volumetric effect`` has promoted the idea of a receiver with tapered ducts. These seems to be very promising since higher efficiency and considerable saving of material can be achieved, as compared to conventional receivers perforated with ducts of constant cross-section. A finite element program is being developed to calculate stationary heat transfer in the tapered ducts by free and forced convection in the gas flow, conduction in walls and in the gas, and solar and thermal radiation. Gas and wall temperatures are considered to be varying only in the flow direction. In order to perform the highly nonlinear calculations of radiative exchange, the exact knowledge of the view factors is necessary. The aim of the present work is to evaluate analytically the view factors in tapered ducts.
1995-02-01
Basic characteristics of centrifuges, (2)
International Nuclear Information System (INIS)
The presence of an extraneous light gas must be taken into account in consideration of centrifugal separation of uranium isotopes, when there is inevitable leakage of such a gas through the gas sealant and/or leaking in from the atmosphere. Consideration is first given to the influence of the presence of the light gas on the maximum separative power. Then the basic equation for isotope separation containing a light gas is derived from Hirschfelder's diffusion equations. This equation is solved and the separative performance is expressed in terms of the shape factor and reflux parameter. The formulas for expressing the flow configurations of the gases are obtained for a simple model in which inflow and outflow prevail throughout the centrifuge. The corresponding equation for a model in which the gases flow in two concentric thin streams is also derived. It is concluded that the influence provided by the presence of a light ...
Forecasting for utility-scale wind farms. The power model challenge
Energy Technology Data Exchange (ETDEWEB)
As the penetration of wind energy continues to increase around the world, with a trend towards large utility-scale wind farms (greater than 100 MW), effective wind energy forecasting will become increasingly important. Previous work by GH has estimated the trading benefit of high quality short-term forecasting to be EUR 7/MWh. Depending on market conditions, for a 100 MW wind farm with a capacity factor of 30%, this equates to an estimated annual trading benefit of up to EUR 1.8m. To date, a number of studies have focused on the mathematical modelling techniques for forecasting the production from wind farms, looking predominantly at the task of predicting the meteorological conditions at the site. This paper focuses on the final stage of the forecasting process, conversion from a meteorological forecast to a power production forecast. This challenge is particularly significant for utility-scale wind farms. The main body of research in short-term forecasting in ...
2008-07-01
Energy Technology Data Exchange (ETDEWEB)
Horizontal vibrations of elevator cars mainly occur because a car swings as roller guides installed at corners of a car frame move on a winding guide rail at high speeds. Rider comfort in high speed elevators is worsened by these vibrations. Conventional active dampers suppressing horizontal vibrations using ac servo motors make cars heavier so driving power becomes larger, and they are not easily applied to existing elevators. An active damping control method suited to super-high-speed elevators is which can solve these problems. The method suppresses vibrations by generating only enough magnetic force needed to suppress them only when vibrations of the car franc are produced. The vibrations are detected using acceleration detectors and magnets installed on left and right sides of the car frame. A computer simulator was made to analyze phenomena of car vibrations and to verify effects of the proposed magnetic damping controller. It was found ...
1998-03-01
British Library Electronic Table of Contents (United Kingdom)
This paper studies the electrical characteristics of hydrogenated amorphous silicon thin-film transistors (a-Si:H TFTs) under flat and bending situations after AC/DC stress at different temperatures. Stress temperature was varied from 77K to 400K, and threshold voltage shifts were extracted to analyze degradation mechanisms. It was found that high temperature and mechanical bending played important roles under AC stress, with an enhanced stress effect resulting in a more serious degradation. This study also discusses the dependence between the accumulated sum of bias rising and falling time and the threshold voltage shifts under AC stress.
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
Summary Fruit vinegar can be obtained biologically from the fermentation of fruit wine using species of the genera Acetobacter. However, the productivity of vinegar is generally low because of the inhibition by substrate ethanol and product acetic acid. In this research, the yield of acetic acid, as well as the cell growth, in hawthorn vinegar fermentation was enhanced using beer for seed preparation. The higher yield of acetic acid of AC2005 was because of the higher alcohol dehydrogenase and aldehyde dehydrogenase activities caused by using beer for seed preparation. Furthermore, Acetobacter pasteurianus AC2005 showed acid stability during the fed batch fermentation of hawthorn vinegar.
2010-01-01
Evaluation of CO2 adsorption capacity of solid sorbents
British Library Electronic Table of Contents (United Kingdom)
The CO2 adsorption capacity of the low-cost solid sorbents of waste tire char (TC) and chicken waste char (CW) was compared with commercial active carbon (AC) and 5?? zeolite (ZA) using thermogravimetric analysis (TG), pressurized TG, and differential scanning calorimetry (DSC). The sorbents were degassed in a TG up to 150??C to release all gases on the surface of the sample, then cooled down to the designed temperature for adsorption. TG results indicated that the CO2 adsorption capacity of TC was higher than that of CW, but lower than those of AC and ZA. The maximum adsorption rate of TC at 50??C was 0.61% min?1, lower than that of AC, but higher than that of CW, 0.44% min?1. The maximum adsorption rate of ZA at 50??C was 3.1% min?1. When the pressure was over 4?bar, the adsorption rate ...
2011-01-01
Comparison between two different designs in the AC voltage measurement
British Library Electronic Table of Contents (United Kingdom)
In this paper, a comparison is done between two different techniques in measuring the AC voltage. The first technique is the single junction thermal voltage converters (SJTVC) which consist of one thermal element (TE) which its output e.m.f. in the range of 7-12mV and the other is the new designed thermal voltage converters which consist of a number of TEs connected in parallel, series and series/parallel to increase their output e.m.f. (becomes in the range of 35-51mV). The effect of increasing the output e.m.f. is studied in this paper through evaluating the uncertainty budget and proved that its increase has a great effect on the accuracy and the uncertainty of the AC voltage measurement.
2011-01-01
Communication Apprehension and Resting Alpha Range Asymmetry in the Anterior Cortex
British Library Electronic Table of Contents (United Kingdom)
In this study, we examined the relationship between trait-like communication apprehension (CA) and resting alpha range asymmetry in the anterior cortex (AC). Although theory and research in cognitive neuroscience suggest that asymmetry in the AC constitutes a relatively stable, inborn, substrate of emotion, some studies indicate that asymmetry can be increased by experimentally induced transitory anxiety. Transitory anxiety produced by interaction with strangers covaries with trait-like CA, raising questions regarding whether asymmetrical electrical activity in the AC during data collection represents resting levels as assumed in the literature or transitory reactions to dyadic interaction with the experimenter. Because the question if unanswered poses issues for theory and approaches to r...
2011-01-01
11. Preparation of natural radioactive materials
International Nuclear Information System (INIS)
Uranium and thorium ores are the source of natural radionuclides. Briefly described are the original and current methods of long-lived nuclide separation ("2"3"8U, "2"3"5U, "2"2"6Ra, "2"3"0Th, "2"3"1Pa, "2"2"7Ac, "2"3"2Th, "2"2"8Ra+"2"2"8Ac, "2"2"8Th), some short-lived nuclides ("2"3"4Th and "2"2"8Ac), radon, short-lived radon daughter products and long-lived radon daughter products ("2"1"0Pb, "2"1"0Bi, "2"1"0Po). Some nuclides, such as "2"1"0Po or "2"3"1Pa can more easily be producedin reactors. (Ha).
Heat transfer augmentation for high heat flux removal in rib-roughened narrow channels
International Nuclear Information System (INIS)
Heat transfer augmentation in narrow rectangular channels in a target system is a very important method to remove high heat flux up to 12 MW/m"2 generated at target plates of a high-intensity proton accelerator of 1.5 GeV and 1 mA with a proton beam power of 1.5 MW. In this report, heat transfer coefficients and friction factors in narrow rectangular channels with one-sided rib-roughened surface were evaluated for fully developed flows in the range of the Reynolds number from 6,000 to 1,00,000; the rib pitch-to-height ratios (p/k) were 10,20 and 30; the rib height-to-equivalent diameter ratios (k/De) were 0.025, 0.03 and 0.1 by means of previous existing experimental correlations. The rib-roughened surface augmented heat transfer coefficients approximately 4 times higher than the smooth surface at Re=10,000, p/k=10 and k/De=0.1; friction factors increase around 22 times higher. In this case, higher heat flux up to 12 MW/m"2 could be removed ...
2001-04-08
Heat transfer augmentation for high heat flux removal in rib-roughened narrow channels
Energy Technology Data Exchange (ETDEWEB)
Heat transfer augmentation in narrow rectangular channels in a target system is a very important method to remove high heat flux up to 12 MW/m{sup 2} generated at target plates of a high-intensity proton accelerator of 1.5 GeV and 1 mA with a proton beam power of 1.5 MW. In this report, heat transfer coefficients and friction factors in narrow rectangular channels with one-sided rib-roughened surface were evaluated for fully developed flows in the range of the Reynolds number from 6,000 to 1,00,000; the rib pitch-to-height ratios (p/k) were 10,20 and 30; the rib height-to-equivalent diameter ratios (k/De) were 0.025, 0.03 and 0.1 by means of previous existing experimental correlations. The rib-roughened surface augmented heat transfer coefficients approximately 4 times higher than the smooth surface at Re=10,000, p/k=10 and k/De=0.1; friction factors increase around 22 times higher. In this case, higher heat flux up to 12 MW/m{sup 2} could be ...
1997-03-01
Spacer grid effects on post-CHF heat transfer in an annulus geometry
Energy Technology Data Exchange (ETDEWEB)
The term 'Post-CHF' was generally used in the two-phase flow regime in tube flow occurring downstream of the CHF. It has various other names such as dispersed flow, liquid-deficient flow, mist flow and film boiling because the two-phase regime is characterized by a continuous vapor phase with discrete liquid drops and a non-wetted heated surface. The regime has been adopted in a lot of applications including nuclear power plants, fossil power plants, steam generators, refrigeration systems and spray cooling, In particular, this regime has a considerable importance in the areas of light water reactor(LWR) accident analysis (off-normal operating conditions) and design in heat exchangers operating in the once-through mode where subcooled liquid enters the exchanger and superheated vapor exits. Recently, innovative PWRs adopt ...
2005-07-01
Spacer grid effects on post-CHF heat transfer in an annulus geometry
International Nuclear Information System (INIS)
The term 'Post-CHF' was generally used in the two-phase flow regime in tube flow occurring downstream of the CHF. It has various other names such as dispersed flow, liquid-deficient flow, mist flow and film boiling because the two-phase regime is characterized by a continuous vapor phase with discrete liquid drops and a non-wetted heated surface. The regime has been adopted in a lot of applications including nuclear power plants, fossil power plants, steam generators, refrigeration systems and spray cooling, In particular, this regime has a considerable importance in the areas of light water reactor(LWR) accident analysis (off-normal operating conditions) and design in heat exchangers operating in the once-through mode where subcooled liquid enters the exchanger and superheated vapor exits. Recently, innovative PWRs adopt very high ...
2005-05-26
Energy Technology Data Exchange (ETDEWEB)
Preliminary tests have shown that smart-grid systems can significantly reduce home electricity use. A smart grid negates the need for controlled distribution by giving homeowners the ability to monitor rates in real time and modify their use based on energy availability, need and price. Homeowners can also feed the grid alternative power to offset their costs. Studies in the United States have also suggested that the system could reduce carbon emissions by 60 to 211 million tonnes per year. The smart grid would also be less susceptible to major disturbances because it draws power from multiple sources. An added benefit is that the technology could be developed for a fraction of the cost of building traditional energy plants, such as nuclear. However, the success of the smart-grid depends on several technological advances. The flow of power within the system must be digitally controlled and also merged ...
2009-07-01
Energy Technology Data Exchange (ETDEWEB)
The third regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from December 27, 1988 to May 25, 1989. The parallel operation was resumed on April 28, 1989, 123 days after the parallel off. The facilities which were the object of inspection were the reactor proper, reactor cooling system, measurement and control system, fuel facilities, radiation control facilities, waste facilities, reactor containment installation and emergency electric power generation system. On the facilities which were the object of inspection, the appearance, disassembling, leak, function, performance and other inspections were carried out. As the results, significant in indication was observed in 8 bolts for fixing the flow-changing vanes of primary coolant pumps, and broken valve spindles were found, but other abnormality was not found. The works related to this regular inspection were accomplished within the range of ...
1990-03-01
Energy Technology Data Exchange (ETDEWEB)
The hydro-generators suffer during its operative useful life a combination of stresses of nature thermal, electric, mechanics and environmental. With the time, they are going losing the capacity to support those stresses and the power plants suffer, more and more frequently, undesirable stops for repair services and maintenance. In function of the high costs incurred with these stopped, the operation of the power plant can be economically impracticable. That unavailability of the generation for the electric system, it results in reduction of the reliability, burdening the politics of load ruling. The re-potentiation is a proposal that seeks to extend the useful life of hydro-generators, at the same time that it try to rescue the reliability and the readiness of the plant, with larger power. The power increase is usually made possible, or for the surplus of the hydro resources in excess, or for the ...
1996-07-01
Parameter study of the LIFE engine nuclear design
International Nuclear Information System (INIS)
LLNL is developing the nuclear fusion based Laser Inertial Fusion Energy (LIFE) power plant concept. The baseline design uses a depleted uranium (DU) fission fuel blanket with a flowing molten salt coolant (flibe) that also breeds the tritium needed to sustain the fusion energy source. Indirect drive targets, similar to those that will be demonstrated on the National Ignition Facility (NIF), are ignited at #approx#13 Hz providing a 500 MW fusion source. The DU is in the form of a uranium oxycarbide kernel in modified TRISO-like fuel particles distributed in a carbon matrix forming 2-cm-diameter pebbles. The thermal power is held at 2000 MW by continuously varying the "6Li enrichment in the coolants. There are many options to be considered in the engine design including target yield, U-to-C ratio in the fuel, fission blanket thickness, etc. Here we report results of design variations and compare them in terms of various ...
2010-09-01
Modeling of a horizontal steam generator for the submerged nuclear power station concept
Energy Technology Data Exchange (ETDEWEB)
A submerged nuclear power station has been proposed as an alternative power station with a relatively low environmental impact for use by both industrialized and developing countries. The station would be placed 10 m above the seabed at a depth of 30--100 m and a distance of 10--30 km from shore. The submerged nuclear power station would be manufactured and refueled in a central facility, thus gaining the economies of factoryfabrication and the flexibility of short-lead-time deployment. To minimize the size of the submerged hull, horizontal steam generators are proposed for the primary-to-secondary heat transfer, instead of the more traditional vertical steam generators. The horizontal steam generators for SNPS would be similar in design to the horizontal steam generators used in the N-Reactors except the tube orientation is horizontal (the tube's inlet and outlet connection points on the tubesheet are at the same ...
1993-01-01
Modeling of a horizontal steam generator for the submerged nuclear power station concept
Energy Technology Data Exchange (ETDEWEB)
A submerged nuclear power station has been proposed as an alternative power station with a relatively low environmental impact for use by both industrialized and developing countries. The station would be placed 10 m above the seabed at a depth of 30--100 m and a distance of 10--30 km from shore. The submerged nuclear power station would be manufactured and refueled in a central facility, thus gaining the economies of factoryfabrication and the flexibility of short-lead-time deployment. To minimize the size of the submerged hull, horizontal steam generators are proposed for the primary-to-secondary heat transfer, instead of the more traditional vertical steam generators. The horizontal steam generators for SNPS would be similar in design to the horizontal steam generators used in the N-Reactors except the tube orientation is horizontal (the tube`s inlet and outlet connection points on the tubesheet are at the same ...
1993-05-01
Modeling of a horizontal steam generator for the submerged nuclear power station concept
International Nuclear Information System (INIS)
A submerged nuclear power station has been proposed as an alternative power station with a relatively low environmental impact for use by both industrialized and developing countries. The station would be placed 10 m above the seabed at a depth of 30--100 m and a distance of 10--30 km from shore. The submerged nuclear power station would be manufactured and refueled in a central facility, thus gaining the economies of factoryfabrication and the flexibility of short-lead-time deployment. To minimize the size of the submerged hull, horizontal steam generators are proposed for the primary-to-secondary heat transfer, instead of the more traditional vertical steam generators. The horizontal steam generators for SNPS would be similar in design to the horizontal steam generators used in the N-Reactors except the tube orientation is horizontal (the tube's inlet and outlet connection points on the tubesheet are at the same ...
1993-07-06
Original holdings are now kept by the World Data Centre C1 at RAL: http://wdcc1. bnsc.rl.ac.uk MODS DOY = 246 ADID_REF Not applicable LOGICAL_FILE_ID ...
Print sec333photoindex (256 pages)
Electro-Magnet. Antenna Panels Types Simulated Hail Stone Damage A.Panel ...... X-Band Klystron Electro Magnet. 11. I I. 333-6104 AcBc. 333-6105 Color ...
Explicit risk in acute coronary syndrome management
UK PubMed Central (United Kingdom)
At least implicitly, most clinical decisions represent an integration of disease and treatment-based risk assessments. Often, as is the case with acute coronary syndrome (ACS), these decisions need...Full Text Available
2009-06-01
Computational Analysis of Dynamic SPK(S8)-JP-8 Fueled ...
the Advanced Distillation Curve, Energy & Fuels, Vol. 22, No. 2, pp. 11041114. http://pubs.acs.org/doi/full/10.1021/ef700562c. Lemmon, E. W., Huber, M. L., ...
UK PubMed Central (United Kingdom)
Antiplatelet agents are the cornerstone of treatment for patients with acute coronary syndrome (ACS) undergoing percutaneous coronary intervention (PCI). Clopidogrel, when added to aspirin, has demonstrated...Full Text Available
2009-01-01
UK PubMed Central (United Kingdom)
The synthesis of an extracellular ribbon of cellulose in the bacterium Acetobacter xylinum takes place from linearly arranged, membrane-localized, cellulose-synthesizing and extrusion complexes that...Full Text Available
1994-09-01
UK PubMed Central (United Kingdom)
We investigated the ability of N-benzyl-N-ethyl-2-(7,8-dihydro-7-methyl-8-oxo-2-phenyl-9H-purin-9-yl)acetamide...Full Text Available
2004-08-01
Adhesive capsulitis and dynamic splinting: a controlled, cohort study
UK PubMed Central (United Kingdom)
BackgroundAdhesive Capsulitis (AC) affects patient of all ages, and stretching protocols are commonly prescribed for this condition. Dynamic splinting has been shown effective in...Full Text Available
Abciximab: a reappraisal of its use in coronary care
UK PubMed Central (United Kingdom)
Platelet reactivity plays a pivotal role in the pathogenesis of ischemic adverse events during and after acute coronary syndromes (ACS), and percutaneous coronary intervention (PCI). Glycoprotein (GP)...Full Text Available
2008-03-01
AC-130H Gunship Armor Upgrade Project
Energy Technology Data Exchange (ETDEWEB)
This report covers the test methods and equipment for testing aircraft armor both hard and soft. The hard armor are the typical ceramic type while the soft armor are various types of layered composite materials. 10 figs. (JEF)
1990-09-19
Visualization by PIV of dynamic stall on a vertical axis wind turbine
Energy Technology Data Exchange (ETDEWEB)
The aerodynamic behavior of a vertical axis wind turbine (VAWT) is analyzed by means of 2D particle image velocimetry (PIV), focusing on the development of dynamic stall at different tip speed ratios. The VAWT has an unsteady aerodynamic behavior due to the variation with the azimuth angle {theta} of the blade's sections' angle of attack, perceived velocity and Reynolds number. The phenomenon of dynamic stall is then an inherent effect of the operation of a VAWT at low tip speed ratios, impacting both loads and power. The present work is driven by the need to understand this phenomenon, by visualizing and quantifying it, and to create a database for model validation. The experimental method uses PIV to visualize the development of the flow over the suction side of the airfoil for two different reference Reynolds numbers and three tip speed ratios in the operational regime of a small urban wind turbine. The field-of-view of the ...
2009-01-15
Turbulent heat transfer augmentation using microscale disturbances inside the viscous sublayer
Energy Technology Data Exchange (ETDEWEB)
The authors report here on an experimental study of heat transfer augmentation in turbulent flow. Enhancement strategies employed in this investigation are based on the near-wall mixing processes induced in the sublayer through appropriate wall and near-wall streamwise-periodic disturbances. Experiments are performed in a low-turbulence wind-tunnel with a high-aspect-ratio rectangular channel having either (a) two-dimensional periodic microgrooves on the wall, or (b) two-dimensional microcylinders placed in the immediate vicinity of the wall. It is found that microdisturbances placed inside the sublayer induce favorable heat-transport augmentation with respect to the smooth-wall case, in the near-analogous momentum and heat transfer behavior are preserved; a roughly commensurate increase in heat and momentum transport is termed favorable in that it leads to a reduction in the pumping power penalty at fixed heat removal rate. The study shows ...
1992-05-01
Influence of moisture on flow property indicators of poor quality anthracite
Energy Technology Data Exchange (ETDEWEB)
Describes investigations into flow density, angle of repose, coefficients of friction and adhesion using poor quality anthracite culm (from the 50-letie Ukrainy mine) and anthracite slurry with a high ash content (from the Tsentral'naya and Partizanskaya mines) on samples of varying moisture content (2-22%). The results show that flow properties are impaired when anthracite has a moisture content of 8.5 to 9.5%; when these anthracites are used in electric power plants they should be stored in bunkers with walls with a slope of greater than 70 degrees (or dried) to prevent sticking. Results of investigations into internal and external friction, adhesion and cohesion varied for the different samples, but the highest coefficient of internal friction was found with concrete where it increases continuously with moisture content. With rubber, PVC, St. 3 steel and stainless steel, the friction coefficient increases with ...
1988-03-01
Fluid dynamics analysis of a Ranque-Hilsch vortex tube
International Nuclear Information System (INIS)
Fluid dynamic analysis of a commercial, counter-flow Ranque-Hilsch Vortex Tube (Rh vt), Ex air 25 s cfm, has been performed in this work both experimentally and numerically; in particular Rh vt cooling power and temperature separation performances have been tested in both direct cooling employment (jet impingement) and indirect cooling employment (supplying cold plates). Experimental techniques, used in this work, revealed several difficulties to produce detailed information about velocity and temperature fields inside the tube and at both the exits. Hence numerical simulation of the flow inside the tube has been conducted using the commercial Cfd code Fluent 6.3.26. Compressible, turbulent, high swirling flow inside Rh vt has been simulated by using both Rans and Les approaches. In particular several turbulence closures have been used in the Rans simulations and results have been compared with Les ...
2008-05-01
Estimating $\\omega$ from Galaxy Redshifts Linear Flow Distortions and Nonlinear Clustering
We propose a method to determine the cosmic mass density Omega from redshift-space distortions induced by large-scale flows in the presence of nonlinear clustering. Nonlinear structures in redshift space such as fingers of God can contaminate distortions from linear flows on scales as large as several times the small-scale pairwise velocity dispersion sigma_v. Following Peacock & Dodds (1994), we work in the Fourier domain and propose a model to describe the anisotropy in the redshift-space power spectrum; tests with high-resolution numerical data demonstrate that the model is robust for both mass and biased galaxy halos on translinear scales and above. On the basis of this model, we propose an estimator of the linear growth parameter beta = Omega^0.6/b, where b measures bias, derived from sampling functions which are tuned to eliminate distortions from nonlinear clustering. The measure is tested on the numerical data ...
1997-01-01
A calculation model for thermo-hydraulic analyses of the PGV-1000 steam generator
International Nuclear Information System (INIS)
A calculation model was developed for the analysis of thermal and hydraulic processes in the PGV-1000 horizontal steam generator. The model makes it possible to examine the hydraulics of the primary medium, i.e., the distribution of flow velocities and mass flows in the exchanger tube system and hydraulic losses of the primary medium in the steam generator during its flow between the two connecting sites to the main circulation pipeline, spatial distribution of heat fluxes between the primary and secondary sides of the steam generator and the total transmitted thermal power, pressure on the secondary side of the generator, natural circulation of the working medium on the secondary side, and the mean circulation number, spatial distribution of the volume fraction of the steam component in the intertubular space, effect of the perforated sheet on the thermo-hydraulic processes in the steam generator, ...
1994-01-01
Energy Technology Data Exchange (ETDEWEB)
TSS (thermal swing sublimation) method was studied which uses vaporization heat and sensible heat of LNG for solidification and separation of CO2 gas in waste gases of LNG-fired combined cycle power generation system. In experiment, the mixed gas composed of CO2, H2O and N2 was used for simulating waste gas of LNG-fired combined cycle power generation systems, and the growth behavior of ice and dry ice was studied for developing dry ice making technology under low-temperature condition. As the experimental result, the following were clarified: various crystal structures depending on cooling temperature, the effect of gas flow rate on peeling of surface precipitated solids, and solidification characteristics of H2O/CO2 mixed gas. The growth rate of precipitated solid film thickness decreased with an increase in gas flow rate, while increased with CO2 concentration. The shape of a dry ice sublimator ...
1997-03-21
Simulation of SBWR startup transient and stability
The Simplified Boiling Water Reactor (SBWR) designed by General Electric is a natural circulation reactor with enhanced safety features for potential accidents. It has a strong coupling between power and flow in the reactor core, hence the neutronic coupling with thermal-hydraulics is specially important. The potential geysering instability during the early part of a SBWR startup at low flow, low power and low pressure is of particular concern. The RAMONA-4B computer code developed at Brookhaven National Laboratory (BNL) for the SBWR has been used to simulate a SBWR startup transient and evaluate its stability, using a simplified four-channel representation of the reactor core for the thermal-hydraulics. This transient was run for 20,000 sec (5.56 hrs) in order to cover the essential aspect of the SBWR startup. The simulation showed that the SBWR startup was a very challenging event to analyze as it ...
1998-06-01
Design and experimental results on a terawatt magnetically controlled plasma opening switch
Energy Technology Data Exchange (ETDEWEB)
The magnetically controlled plasma opening switch (MCPOS) is an advanced plasma opening switch that utilizes magnetic fields to improve operation. Magnetic fields always dominate terawatt, pulsed power plasma opening switches. For that reason, the MCPOS uses controlled applied magnetic fields with magnitude comparable to the self-magnetic field of the storage inductor. One applied field holds the plasma in place while energy accumulates in the storage inductor, then another applied field pushes the plasma away from the cathode to allow energy to flow downstream. Over a ten month period, an MCPOS was designed, built, and tested on DECADE Module 2 at Physics International. The peak drive current was 1.8 MA in 250 ns. The output parameters were up to 1 MA into an electron beam load. The radiation temporal pulse width averaged 60 nanoseconds full-width at half-maximum. The peak load voltage ranged from one to two megavolts. The experiments ...
1998-05-01
AP1000 plant construction in China: Ansaldo Nucleare contribution
International Nuclear Information System (INIS)
On 24th of July 2007 Westinghouse Electric Co. signed landmark contracts with China's State Nuclear Power Technology Corporation (SNPTC), to provide four AP1000 nuclear power plants in China. The AP1000 is a two-loop 1117 MWe Pressurized Water Reactor (PWR). It is based on proven technology, but with an emphasis on safety features that rely on natural driving forces, such as pressurized gas, gravity flow, natural circulation flow and convection. Ansaldo Nucleare has provided a significant support to the passive plant technology development and, starting from 2000, is cooperating with Westinghouse to development of the AP1000 Plant. In the frame of the AP1000 Chinese agreement, Ansaldo Nucleare, in Joint Venture with Mangiarotti Nuclear, has signed a contract with Westinghouse for the design and the supply of innovative components to be installed in the first AP1000 unit to be constructed at the Sanmen ...
2009-10-12
A space crystal diffraction telescope for the energy range of nuclear transitions
Energy Technology Data Exchange (ETDEWEB)
This paper contains literature from American Power Conference Air Toxics Being Measured Accurately, Controlled Effectively NO{sub x} and SO{sub 2} Emissions Reduced; Surface Condensers Improve Heat Rate; Usable Fuel from Municipal Solid Waste; Cofiring Technology Reduces Gas Turbine Emissions; Trainable, Rugged Microsensor Identifies of Gases; High-Tc Superconductors Fabricated; High-Temperature Superconducting Current Leads; Vitrification of Low-Level Radioactive and Mixed Wastes; Characterization, Demolition, and Disposal of Contaminated Structures; On-Line Plant Diagnostics and Management; Sulfide Ceramic Materials for Improved Batteries; Flywheel Provides Efficient Energy Storage; Battery Systems for Electric Vehicles; Polymer-Electrolyte Fuel Cells for Transportation; Solid-Oxide Fuel Cells for Transportation; Surface Acoustic Wave Sensor Monitors Emissions in Real-Time; Advance Alternative-Fueled Automotive Technologies; Thermal & Mechanical Process; ...
1995-04-01
Energy Technology Data Exchange (ETDEWEB)
The paper presents a computer-aided analysis of the combined use of ventilation and structural heat capacity and insulation as a means of saving air-conditioning power in digital telephone exchanges. It is shown that such savings can be effected by increasing air change with outdoor cool air at night, and when feasible, also in daytime, through the air change unit, in a conventional airconditioning cycle. The total thermal time constant (TTTC) method of calculation used enables the evaluation of daily or seasonal heat-flow balance for a given indoor temperature, considering the tendency of the heat capacity of the building and of envelope components to flatten the fluctuations of this temperature.
1984-12-01
UK Achievements in the application of power fluidic technology for nuclear processing plants
International Nuclear Information System (INIS)
Power Fluidic systems for the control of liquids and gaseous flows have been adopted for use in radioactive processing plants in the UK. These devices are intrinsically reliable with no mechanical moving parts because they are able to make use of the hydrodynamics of the fluids being controlled. This reliability feature leads to a zero cell maintenance concept and the elimination of mechanical drive/control systems in cell. The first phase of the development work led to their use in the Fast Reactor Reprocessing Plant at Dounreay and the Highly Active Liquor Storage facility at Sellafield. The success of these early developments has led to an extensive development programme for an extended range of applications in the Thermal Oxide Reprocessing Plant and its associated waste treatment facilities at Sellafield. The technology has now been fully demonstrated and adopted for these plants with considerable benefit over a wide range of applications.
Thermal loads on tokamak plasma-facing components during normal operation and disruptions
Energy Technology Data Exchange (ETDEWEB)
Power loadings experienced by tokamak plasma-facing components during normal operation and during off-normal events are discussed. A model for power and particle flow in the tokamak boundary layer is presented and model predictions are compared to infrared measurements of component heating. The inclusion of the full three-dimensional geometry of the components and of the magnetic flux surface is very important in the modeling. Experimental measurements show that misalignment of component armour tile surfaces by only a millimeter can lead to significant localized heating. An application to the design of plasma-facing components for future machines is presented. Finally, thermal loads expected during tokamak disruptions are discussed. The primary problems are surface melting and vaporization due to localized intense heating during the disruption thermal quench and volumetric heating of the component armour and structure due ...
1990-01-01
The Australian Geographic Team Marsupial solar-powered car
Energy Technology Data Exchange (ETDEWEB)
As in all vehicles of this type, low weight and aerodynamic drag must be achieved without compromising safety, and in an extremely rugged structure. This has been done by using a chrome-molybdenum steel space-frame, surrounded by a Kevlar/foam sandwich body shell. The solar panel wing, which uses a laminar flow section to obtain low drag, does not tilt except when the vehicle is stationary. A high degree of redundancy is built into the vehicle; for example there are two motors and transmissions, the solar array is divided into seven parallel sub-arrays, and the power electronics is multiply redundant. Built entirely in the garage of a suburban house, the Australian Geographic Team Marsupial car cost less than US$50,000 to construct.
1988-01-01
Energy Technology Data Exchange (ETDEWEB)
This final report for the Swiss Federal Office of Energy (SFOE) presents the results of a project that involves the building of a joint biogas plant serving 60 farmers and industrial companies with an annual processing capacity of 45,000 tons. The plant is to produce biogas to be fed into the gas mains and will not only reduce nutrient loading in a region with an extensive livestock industry but also reduce carbon dioxide emissions by using the gas as a motor fuel. The importance of the project with respect to both the environment and energy policy-making is discussed and the costs involved are examined. Details are presented on the technology used and on the material flows involved. Figures are quoted on energy production. The various biogenic substrates used, such as food wastes, waste oils, cereal wastes and used mushroom substrates, are discussed, as is the use of the solid and liquid outputs of the digester in farming activities.
2005-07-01
Steam generator tube performance: experience with water-cooled nuclear power reactors during 1979
International Nuclear Information System (INIS)
The performance of steam generator tubes in water-cooled nuclear power reactors has been reviewed for 1979. Tube failures occurred at 38 of the 93 reactors surveyed. Causes of these failures and procedures designed to deal with them are described. The defect rate was twice that in 1978 but still lower than the two previous years. Methods being employed to detect defects include increasing use of multifrequency eddy-current testing and a trend to full-length inspection of all tubes. To reduce the incidence of tube failures by corrosion, plant operators are turning to full-flow condensate demineralization and more leak-resistant condenser tubes. (author).
1994-10-18
Road maps on research and development plans for water chemistry of nuclear power systems
International Nuclear Information System (INIS)
Water chemistry of nuclear power plants has played an important role in reduction of personnel doses, structural materials and fuel integrity assurance, and reduction of radioactive wastes production. Further contributions are requested for advanced utilization of the LWR, advanced fuels and aging management of plants. Since water chemistry has an effect on all structure and materials immersed and at the same time affected by them, the optimum control not sticking to specific issues and covering the whole plant is required for these requests. Taking account of roles and activities of the industry, governmental institutes and academia, road maps on research and development plans for water chemistry were compiled into identified eleven items with targets and counter measures taken, such as common basic technologies, dose reduction, SCC mitigation, fuel cans corrosion/hydrogen absorption mitigation, condition based maintenance and flow accelerated ...
2008-05-01
Energy Technology Data Exchange (ETDEWEB)
This is a process for producing calcium sulfate dihydrate during desulfurization of stack gases from power station boilers, where the stack gases are introduced into a washing tower and are treated with a washing water suspension containing lime in the washing tower, where oxygen in the form of air or of air enriched in oxygen is also blown into the washing tower, and where the washing water suspension drawn off from the washing tower is fed back to the washing tower at a temperature of 45 to 50/sup 0/C in the circuit and at least part of the flow goes via a thickener and where calcium sulfate dihydrate slurry is drawn off from the thickener.
1986-06-12
Parameter study of the LIFE engine nuclear design
British Library Electronic Table of Contents (United Kingdom)
LLNL is developing the nuclear fusion based Laser Inertial Fusion Energy (LIFE) power plant concept. The baseline design uses a depleted uranium (DU) fission fuel blanket with a flowing molten salt coolant (flibe) that also breeds the tritium needed to sustain the fusion energy source. Indirect drive targets, similar to those that will be demonstrated on the National Ignition Facility (NIF), are ignited at 13Hz providing a 500MW fusion source. The DU is in the form of a uranium oxycarbide kernel in modified TRISO-like fuel particles distributed in a carbon matrix forming 2-cm-diameter pebbles. The thermal power is held at 2000MW by continuously varying the 6Li enrichment in the coolants. There are many options to be considered in the engine design including target yield, U-to-C ratio in th...
2010-01-01
International Nuclear Information System (INIS)
Fly ash from Lagisza power station with addition of kaolin and calculated amount of carbon was reacted in flowing nitrogen at 1520"oC in order to obtain #beta#-sialon. The resulted powder was sintered with and without Y_2O_3 addition. Examinations show that it is possible to sinter that material without any sintering additives, however additive of Y_2O_3 decreases sintering temperature of about 100"oC. Sintering temperature influences the final mechanical properties like: flexural strength, microhardness, Young elastic modulus (E) and fracture toughness (K_I_c). (author)
2004-09-12
Heber Geothermal Binary Demonstration Project. Final design availability assessment. Revision 1
Energy Technology Data Exchange (ETDEWEB)
An availability assessment of the principal systems of the Heber Geothermal Power Plant has been carried out based on the final issue of the process descriptions, process flow diagrams, and the approved for design P and IDs prepared by Fluor Power Services, Inc. (FPS). The principal systems are those which contribute most to plant unavailability. The plant equivalent availability, considering forced and deferred corrective maintenance outages, was computed using a 91 state Markov model to represent the 29 principal system failure configurations and their significant combinations. The failure configurations and associated failure and repair rates were defined from system/subsystem availability assessments that were conducted using the availability assessments based on the EPRI GO methodology and availability block diagram models. The availability and unavailability ranking of the systems and major equipment is presented.
1983-02-01
Decontamination for radioactive working dresses using liquid and supercritical carbon dioxide
Energy Technology Data Exchange (ETDEWEB)
A decontamination washer for working dresses using liquid and supercritical carbon dioxide were designed and manufactured. The size of reactor for decontamination and solidification is about 16 liter. The system is a closed one with recycling ability of carbon dioxide. The efficiency of recycling of carbon dioxide and that of separation of solutes in carbon dioxide were checked. They met all the design goals. A remote control system of the carbon dioxide flow was set in a control panel. The manufactured decontamination washer was brought to Wolsung nuclear power plants, and installed to check the efficiency of decontamination and the feasibility of usage in nuclear power plants. The elimination of radioactive oil from the contaminated dresses were very high. However, the decontamination factor was lower than the design goal value. It's due to the low removal rate of radioactive particles attached on the dresses.
2000-05-01
Energy Technology Data Exchange (ETDEWEB)
The usefulness of radioiodination via demetallation of aryltrimethylsilanes was demonstrated. The radioiodination reaction was found to be very rapid and the regiospecific incorporation of radioiodine could be carried out with high radiochemical yields and high radiospecific activity. {sup 125}I-Labeled dimethylaminoethyl iodophenoxyacetate derivatives (5a-e), dimethylaminoethyl iodophenoxyacetamide derivatives (7a-c), iodophenoxyethyl ethylenediamine derivatives (9,14) and an iodophenoxyethylpiperazine derivative (18) were efficiently synthesized from the corresponding aryltrimethylsilyl intermediates (4a-e, 6a-c, 8, 13, 17) by this method. (author).
1989-09-01
Radioiodinated phenoxyacetic acid derivatives as potential brain imaging agents, 1
International Nuclear Information System (INIS)
The usefulness of radioiodination via demetallation of aryltrimethylsilanes was demonstrated. The radioiodination reaction was found to be very rapid and the regiospecific incorporation of radioiodine could be carried out with high radiochemical yields and high radiospecific activity. "1"2"5I-Labeled dimethylaminoethyl iodophenoxyacetate derivatives (5a-e), dimethylaminoethyl iodophenoxyacetamide derivatives (7a-c), iodophenoxyethyl ethylenediamine derivatives (9,14) and an iodophenoxyethylpiperazine derivative (18) were efficiently synthesized from the corresponding aryltrimethylsilyl intermediates (4a-e, 6a-c, 8, 13, 17) by this method. (author).
... John Cannaday and Ken Weddle present the framework for a Product Design Engineering project (http://engineering.dartmouth.edu/~teps/images/ProductDesign.pdf) for high school students which may have relevance at a more advanced level. David Price has created a Mechanical Engineering Design (http://www.soton.ac.uk/~cds/) site containing engineering design notes. The Virtual Reality Engineering Library Home Page at the University of Bristol (http://www.dig.bris.ac.uk/virtual_lib/) is a library ...
Energy Technology Data Exchange (ETDEWEB)
The influences of temperature and duration of tempering on hardness and microstructure were investigated at high-temperature martensitic and low-carbon steels with 9% chrome and the further alloying elements molybdenium, vanadium, niobium and partially tungsten. After austenitizing and subsequent air cooling the steels were tempered at temperatures below, at and above Ac{sub 1b} for different times and finally a hardness test was performed. Making use of the temperature dependence of the hardness tempering diagrams were constructed and the Hollomon-Jaffe-Parameter on the three steels was determined within its application limits. Micrographs of the structure shows the formation of the carbides and the martensite. At tempering temperatures below Ac{sub 1b} a decrease of hardness occurs, above Ac{sub 1b}, a hardness rise due to the partial austenitizing was obtained. While hardening below Ac{sub 1b}, the ...
1999-06-01
A. C. losses in the SSC high energy booster dipole magnets
Energy Technology Data Exchange (ETDEWEB)
The baseline design for the SSC High Energy Booster (HEB) has dipole bending magnets with a 50 mm aperture. An analysis of the cryogenic heat load due to A.C. losses generated in the HEB ramp cycle are reported for this magnet. Included in this analysis are losses from superconductor hysteresis, yoke hysteresis, strand eddy currents, and cable eddy currents. The A.C. loss impact of 2.5 {mu}m vs. 6 {mu}m filament conductor is presented. A 60 mm aperture design is also investigated. 8 refs., 3 tabs.
1991-06-01
International Nuclear Information System (INIS)
Natural convection of vaporizing Deuterium at 25 K transports the heat generated in the moderator cell of the cold neutron source to a He cooled condenser. The thermohydraulics of this thermosiphon were precalculated and the results verified by experiments in a 1:1 model using D_2 as fluid. The experimental results show that the thermosiphon operates stable. The demanded liquid content of the cell as well as wall temperatures below 50 K can be ensured by a proper design of the cell outlet flow geometry. A 7 min. loss of cryogenic power results in transient temperatures of the cell wall of not more than 300 K.
1991-08-01
Energy Technology Data Exchange (ETDEWEB)
The rate at which full-scale technology transfer takes place depends on the quality of the supply companies, i.e. training, organisational development and product infrastructure. These parameters are discussed for the example of a water mill, and a flow diagram is presented. [Deutsch] Wie rasch ein umfassender Transfer in Frage kommt, entscheidet sich mit der Qualitaet und dem Niveau der zuliefernden Betriebe. Hierbei sind Ausbildung, Organisationsentwicklung und Produktionsinfrastruktur besonders angesprochen. Fuer eine Wassermuehle werden diese Parameter konkret eroertert und an Durchlaufdiagrammen erlaeutert. (GL)
1997-12-31
Energy Technology Data Exchange (ETDEWEB)
In order to ensure a power balance in an electrical network a spinning reserve has to be capable of activation within seconds. However, because of the need to vary the fuel flow in the steam generator, the run-up of output takes minutes. The required capacity response is therefore achieved by storage of steam from the steam generator. In this process the turbine control valves come into action in a specific manner. The paper describes the importance of the initial reserve for unit capacity control. (orig.).
1989-09-01
Porting Decision Tree Algorithms to Multicore using FastFlow
The whole computer hardware industry embraced multicores. For these machines, the extreme optimisation of sequential algorithms is no longer sufficient to squeeze the real machine power, which can be only exploited via thread-level parallelism. Decision tree algorithms exhibit natural concurrency that makes them suitable to be parallelised. This paper presents an approach for easy-yet-efficient porting of an implementation of the C4.5 algorithm on multicores. The parallel porting requires minimal changes to the original sequential code, and it is able to exploit up to 7X speedup on an Intel dual-quad core machine.
2010-01-01
Grid-controlled plasma cathodes
International Nuclear Information System (INIS)
Experiments are described on a plasma cathode with biased grids to prevent entry of ions into the electron extraction gap. The cathode has potential applications to the generation of high-current pulsed electron beams. Operation at 20 A/cm"2 is theoretically possible. The source combines the low average power consumption of a plasma cathode with many of the attractive features of thermionic cathodes, such as space-charge-limited extractor gap electron flow, fast turn-on, and no diode closure. Initial experiments are reported at the 2 A/cm"2 level for pulse lengths to 160 #mu#s.
Energy Technology Data Exchange (ETDEWEB)
With the compensator-series equipment put into operation in 1992 - giving a performance of 330 Mvar - it was made possible for high-performance electronics to use a continuously variable, fully loaded power transmission line and to regulate the energy flow and minimise overcurrent losses. As well as these technical qualities, this system could offer environmental advantages for European implementation. This would avoid the need to plan and construct new high voltage transmission lines in order to meet increased demand. (orig.)
1994-06-01
Energy Technology Data Exchange (ETDEWEB)
The performance of a solar chemical heat pipe was studied using CO{sub 2}reforming of methane as the endothermic reaction. A directly heated vertical reactor, packed with a rhodium catalyst was used. The solar tests were carried out in the Schaeffer solar furnace of the Weizmann Institute of Science. The power absorbed was up to 6.3 KW, the maximal flow rates of the gases reached 11,000 1/h, and the methane conversions reached 85%. A computer model was developed to simulate the process. Agreement of the calculations with the experimental results was quite satisfactory.
1992-01-01
Automatic control of the Wattenberg Gas Field, Colorado
Energy Technology Data Exchange (ETDEWEB)
This paper discusses the successful implementation of automatic control in the Wattenberg Gas Field in northern Colorado. Also discussed is the use of solar powered Amocams equipment to affect continuous monitoring and control of these tight gas wells. The control system includes an algorithm which continuously adjusts the production cycling based on changes in the individual well's producing pressures and flow rates. This strategy has been successful in enhancing production and reducing the number of wells logged off due to excessive fluid buildup. The benefits derived from this system are enumerated and the impacts on field operations are discussed.
1982-09-01
International Nuclear Information System (INIS)
The efficient use of the fuel is one of the objectives in the assemblies design of type BWR. The present tendency in the assemblies design of type BWR is through a radial distribution of enrichments. The present work has like object showing the because of this decision, for what a comparison of the neutronic performance of two fuel cells with the same enrichment average but one of them with radial distribution of enrichment and the other with a single enrichment equal to the average. The cells were analyzed with the CASMO-4 code and the obtained results of the behavior of the neutron flow and the power sustain the because of the radial distribution of enrichments. (Author)
2008-07-06
A study on the regulatory approach of KNGR multiple failure events
Energy Technology Data Exchange (ETDEWEB)
This project is to provide the regulatory direction of containment bypass during multiple steam generator tube failure issue for the Korean Next Generation Reactors, which is a part of major technical issues resulted from the safety regulation R and D on the KNGR. The outstanding results are as follows : the Multiple Steam Generator Tube Repture(MSGTR) event has never been occurred in the history of commercial nuclear reactor operation but single Steam Generator Tube Rupture(SGTR) event is reported to occur every two years. A probabilistic safety analysis study on MSGTR event, however, show its probability of occurrence is to be the same order as the design basis accidents such as LACA. In this regard, the ability of NPPs to cope with MSGTR event is required. Some requirements on initial and boundary conditions are suggested to be used in the analyses of NPPs during MSGTR events. The items that should be considered in establishing regulatory requirements are summarized as follows : the ...
2001-01-15
The study of the intrinsic behavior of high transition temperature copper-oxide superconductors (HTSC) has proven to be challenging because of the extreme sensitivity of their transport properties on material quality. These compounds are characterized by a high degree of structural and electrical anisotropy, and a very short superconductive coherence length of the same order as the size of the crystalline unit cell (~5-30 A). As a result, microscopic defects such as oxygen vacancies, cationic disorder, and the presence of minute impurities have a significant effect on electrical transport in these materials. Therefore, much effort has been expended in synthesizing sizable samples that are homogeneous, well characterized, and emenable to the study of the anisotropic properties of the HTSC. We have demonstrated that thin films of HTSC compounds such as rm YBa_2Cu_3O_{7 -delta}, which is a 92 K superconductor, can be synthesized easily by a technique known as pulsed laser deposition, and ...
1992-01-01
Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques
International Nuclear Information System (INIS)
Positron emission tomography (PET) is a fully quantitative technology for imaging metabolic pathways and dynamic processes in vivo. Attenuation correction of raw PET data is a prerequisite for quantification and is typically based on separate transmission measurements. In PET/CT attenuation correction, however, is performed routinely based on the available CT transmission data. Recently, combined PET/magnetic resonance (MR) has been proposed as a viable alternative to PET/CT. Current concepts of PET/MRI do not include CT-like transmission sources and, therefore, alternative methods of PET attenuation correction must be found. This article reviews existing approaches to MR-based attenuation correction (MR-AC). Most groups have proposed MR-AC algorithms for brain PET studies and more recently also for torso PET/MR imaging. Most MR-AC strategies require the use of complementary MR and transmission images, or morphology ...
2009-03-01
Reynolds Number Effects in Transonic Flow
... of drag measurements with the AGARD Nozzle Afterbody ... are discussed separately from flows with a ... bubbles introduce typical flow phenomena that ...
1988-12-01
... 65th AGARD Fluid Dynamics Symposium, Madrid, Spain, October ... of research programs on flow control ... separation, and delta wing flows formed the ...
1991-04-30
On Issues Concerning Flow Separation and Vortical Flows in Three ...
impflrtant to the understanding of complex vortical flows. ... tions like the slender wing, flow separations are controlled in the s,. ...... 10, AGARD LS-121, Dec. ...
Industrial-process control valves Part2 : Flow capacity Section Four : Inherent flow characteristics and rangeability
1989-01-01
Energy Technology Data Exchange (ETDEWEB)
The core bypass phenomenon of borated water injected through direct vessel injection (DVI) nozzles in APR1400 (Advanced Power Reactor 1400MWe) during main steam line break (MSLB) accidents with a reactor coolant pump (RCP) running mode has been simulated using a two-channel and one-dimensional system analysis model code (MARS), and a three-dimensional computational fluid dynamics (CFD) code (FLUENT). A visualization experiment has also been performed using a scaled-down model of the APR1400. The MARS analysis has predicted a serious core bypass phenomenon of borated water, while the CFD analysis has shown results opposite to the MARS results. The CFD analysis has shown that the flow pattern in the downcomer is fully three-dimensional and that vortex flow structures are formed near the cold legs so that the borated water might pass without difficulty into the high flow region of the cold legs and ...
2007-04-15
High pressure waterjets for oil containment in calm and wavy waters; a parametric study
International Nuclear Information System (INIS)
The use of high pressure waterjets (HPWJ) as oil barriers has been proposed and tested. It has been shown that a series of waterjets directed horizontally above the free water surface provide an effective means of containing or deflecting oil slicks. The waterjets generate a high speed air flow capable of moving the surface layer of the liquid. A numerical model is implemented to study the characteristics of the entrained turbulent air flow using the Spectral Element Method (SEM) and an algebraic turbulent model for the Reynolds stresses. A test of the code is done for turbulent Couette Flow to check the accuracy of the calculated shear stresses against published data. A parametric study is performed to evaluate the HPWJ system performance at various operating and design parameters which include manifold pressure, nozzle flow rate, nozzle characteristics, jet height and surface wave conditions. The ...
1994-01-01
CFD simulation of steam generator tube rupture thermal-hydraulics
Energy Technology Data Exchange (ETDEWEB)
Several steam generator tube rupture accidents have occurred at plants in the past. In this paper the Computational Multi-Fluid Dynamics (CMFD) investigation of the horizontal steam generator thermal-hydraulics during the tube rupture accident is performed. A guillotine of a steam generator U-tube is assumed with choked flow from the primary to the secondary side of the steam generator. We have computed water and steam velocity fields, steam volume fraction distribution on the steam generator secondary (shell) side, as well as the swell level increase. The simulation results are a support to the safety analyses of the steam generator tube rupture accident. Numerical simulation is performed with the multidimensional multi-fluid modelling approach. The two-phase flow around steam generator tubes in the bundle is modelled by the porous media approach. Interfacial mass, momentum and energy transfer are modelled with the closure laws. The governing ...
2004-07-01
Energy Technology Data Exchange (ETDEWEB)
This document presents the analysis of the simulation of the loss of coolant accident at uprate power conditions, that is 2027 MWt (105% of the current rated power of 1931MWt). This power was reached allowing an increase in the turbine steam flow rate without changing the steam dome pressure value at its rated conditions (1020 psiaJ. There are also presented the results of the simulation of the main steam isolation va/ve transient at overpressure conditions 1065 psia and 1067 MWt), for Laguna Verde Nuclear Power Station. Both simulations were performed with the best estimate computer code TRA C BF1. The results obtained in the loss of coolant accident show that the emergency core coolant systems can recover the water level in the core before fuel temperature increases excessively, and that the peak pressure reached in the drywell is always below its design pressure. Therefore it is ...
2001-07-01
Heat Transfer Enhancement of Nanofluid in Natural Convection of an Enclosure Heated from Below
Energy Technology Data Exchange (ETDEWEB)
The general strategy for improving the safety of nuclear power plant and its economics is to accomplish power uprates while securing sufficient thermalhydraulic margin. In order to succeed this strategy, there have been a lot of efforts in increasing the margin through the enhancement of heat transfer capability in coolants. However, despite their efforts, only about 10 {approx} 15 % increase of the thermal margin is possible by using the best art known well up to now with installation of mechanical engineering devices such as mixing vane or button to generating the swirl flow and turbulent mixing. The limit of the capability of the best technique has made a lot of engineers to be frustrated to do the power uprates. Nevertheless, fortunately a new innovative idea is being proposed in heat transfer community as an engineering colloidal fluid to basically change the original properties of the coolant. The ...
2005-07-01
Wall thinning trend analyses for secondary side piping of Korean NPPs
International Nuclear Information System (INIS)
Since the mid-1990s, nuclear power plants in Korea have experienced wall thinning, leaks, and ruptures of secondary side piping caused by flow-accelerated corrosion (FAC). The pipe failures have increased as operating time progresses. In order to prevent the FAC-induced pipe failures and to develop an effective FAC management strategy, KEPRI and KOPEC have conducted a study for developing systematic FAC management technology for secondary side piping of all Korean nuclear power plants. As a part of the study, FAC analyses were performed using the CHECWORKS code. The analysis results were used to select components for inspection and to determine inspection intervals on each nuclear power plant. This paper describes the introduction of the FAC analysis method and the wall thinning trend analysis results by reactor type, system, and water treatment amine. This paper also represents the site application ...
2003-08-17
International Nuclear Information System (INIS)
Object: To prevent coolant inventory within a cooling system loop in an atomic power plant from being varied depending on loads thereby relieving restriction of varied speed of coolant flow rate to lowering of a liquid surface due to short in coolant. Structure: Instruments such as a superheater, an evaporator, and the like, which constitute a cooling system loop in an atomic power plant, have a plurality of free liquid surface of coolant. Portions whose liquid surface is controlled and portions whose liquid surface is varied are adjusted in cross-sectional area so that the sum total of variation in coolant inventory in an instrument such as a superheater provided with an annulus portion in the center thereof and an inner cylindrical portion and a down-comer in the side thereof comes equal to that of variation in coolant inventory in an instrument such as an evaporator similar to the superheater. which is provided with an ...
Development of the modern ALSTOM bowl mill; Entwicklung der modernen ALSTOM-Schuesselmuehle
Energy Technology Data Exchange (ETDEWEB)
Wider coal lines and larger power plant units necessitate measures for increasing the capacity of the mills without driving up power consumption and installation costs. The result of this development is the modern ALSTOM bowl mill. This paper indicates the stages of development which were necessary for this and the experience which could be accumulated through these measures. The paper also describes in detail the areas of flow in the mills, of design of milling equipment, of mill power supply and of grading in this development. (orig.) [Deutsch] Breitere Kohlebaender und groessere Kraftwerkseinheiten zwingen zu Massnahmen, um die Leistung der Muehlen zu vergroessern, ohne jedoch den Kraftbedarf und die Installationskosten in die Hoehe zu treiben. Das Ergebnis dieser Entwicklung ist die moderne ALSTOM-Schuesselmuehle. Der Beitrag zeigt, welche Entwicklungsschritte hierzu erforderlich waren und welche ...
1998-12-01
Flow deflector for nuclear fuel element assemblies
International Nuclear Information System (INIS)
... coolants departure nucleate boiling fluid flow fluidic control devices fuel
Energy Technology Data Exchange (ETDEWEB)
We report the performance of a commercial recuperated micro gas turbine on biomass producer gas and mixtures of biomass producer gas with natural gas. The biomass producer gas, obtained by gasification at 850{sup o}C with air at atmospheric pressure, contains about 7% H2, 17% CO, 15% CO2, 4% CH4, 2% other hydrocarbons, 2% H2O, and a balance of N2 and Ar from air. It has a net heating value of about 6 MJ/(Nm{sup 3}). The micro gas turbine delivers full power (30 kW{sub e}) on gas mixtures with a net heating value of at least 15 MJ/(Nm{sup 3}). For gas of lower heating value, the maximum fuel gas flow allowed by the fuel control unit limits the attainable power. At reduced power, the lower limit for stable operation is a net heating value of about 8 MJ/(Nm{sup 3}). The gross efficiency of the micro gas turbine depends on the output power but not on the gas heating value, within our ...
2007-08-15
Design configurations for stand alone photovoltaic hydrogen power systems (SAPHYS)
Energy Technology Data Exchange (ETDEWEB)
In the Joule II project JOU2-CT 94-0428 `Development and Testing of Stand-Alone small-size Solar Photovoltaic-Hydrogen power Systems (SAPHYS)`, different design configurations are compared and discussed. In this paper we present some of the proposed design configurations and discuss their benefits and drawbacks. Simplified expressions for system efficiency for the different configurations are presented. These expressions are based on average efficiencies for the solar cells, the electrolyzer, the batteries, the hydrogen storage and the fuel cells. Mean fractions of energy passing through the energy storages are also assumed. From considerations in the paper one conclusion becomes apparent, i.e. the direct use of the energy should be maximized. Another conclusion is that one of the most important factors in Solar Photovoltaic Hydrogen Power Systems is the solar cell efficiency. This point seems to be lost in typical projects where focus is put ...
1995-12-31
Thermal/hydraulic tests of tube supports in a multi-tube steam generator model
International Nuclear Information System (INIS)
Tube supports used in the tube bundles of PWR steam generators have consisted of mechanical devices located at intervals along the tube bundle. The presence of tube supports creates regions of restricted flow with altered flow patterns and increased pressure drop. An additional and very important effect is also the possibility of local complete vaporization or dryout occurring in the tube/support flow passage and crevices. The thermal/hydraulic conditions at which dryout occurs are of particular interest because of the possibility of the deposition of dissolved solids with the occurrence of dryout. As long term build-up of solid deposition could have a deleterious effect, knowledge of the conditions at which dryout occurs would possibly provide a means to avoid this build-up. A test program, sponsored by the Steam Generator Project Office of the Electric Power Research Institute, was conducted to ...
1985-03-01
Predicting optimum vortex tube performance using a simplified CFD model
International Nuclear Information System (INIS)
The Ranque-Hilsch tube is a particular type of vortex tube device. The flow enters the device tangentially near one end and exits from the open ends of the tube. The inlet air is of a uniform temperature throughout while the outputs are of different temperatures. One outlet is hotter and the other is colder than the inlet air. This device has no moving parts and does not require any additional power for its operation other than that supplied to the device to compress the inlet air. It has, however, not been widely used, mainly because of its low efficiency. In this paper, a simplified 2-dimensional computational fluid dynamics model for the flow in the vortex tube is developed using FLUENT. This model makes use of the assumption of axial symmetry throughout the entire flow domain. Compared to a three-dimensional computational solution, the simplified model requires significantly less computational time. ...
2004-05-09
Investigation of thermohydraulic parameters during natural convection cooling of TRIGA reactor
International Nuclear Information System (INIS)
Important steady-state thermohydraulic parameters of the TRIGA research reactor operating under natural convection mode of coolant flow were investigated using NCTRIGA computer code. Neutronic parameters used in preparing the input of NCTRIGA were taken from the analysis performed by 3-D Monte Carlo code MCNP4C. Benchmarking of the NCTRIGA calculated results were performed against the experimental data measured by the thermocouples in the instrumented fuel element (IFE) during the steady state operation of the reactor under natural convection mode of coolant flow. Various thermohydraulic parameters like the coolant velocity, flow rate and mass flow rate were generated for the hot channel as well as for the two channels comprising instrumented fuels. Calculated peak fuel temperatures at different power levels were compared with the measured values and also with the calculations ...
2006-09-01
Development and use of localized arc filament plasma actuators for high-speed flow control
International Nuclear Information System (INIS)
The paper discusses recent results on the development of localized arc filament plasma actuators and their use in controlling high-speed and high Reynolds number jet flows. Multiple plasma actuators (up to 8) are controlled using a custom-built 8-channel high-voltage pulsed plasma generator. The plasma generator independently controls pulse repetition rate (0-200 kHz), duty cycle and phase for each individual actuator. Current and voltage measurements demonstrated the power consumption of each actuator to be quite low (20 W at 20% duty cycle). Emission spectroscopy temperature measurements in the pulsed arc filament showed rapid temperature increase over the first 10-20 ?s of arc operation, from below 1000 deg. C to up to about 2000 deg. C. At longer discharge pulse durations, 20-100 ?s, the plasma temperature levels off at approximately 2000 deg. C. Modelling calculations using an unsteady, quasi-one-dimensional arc filament model showed that ...
2007-02-07
Data Center Energy Benchmarking: Part 3 - Case Study on an ITEquipment-testing Center (No. 20)
Energy Technology Data Exchange (ETDEWEB)
The data center in this study had a total floor area of 3,024 square feet (ft{sup 2}) with one-foot raised-floors. It was a rack lab with 147 racks, and was located in a 96,000 ft{sup 2} multi-story office building in San Jose, California. Since the data center was used only for testing equipment, it was not configured as a critical facility in terms of electrical and cooling supply. It did not have a dedicated chiller system but was served by the main building chiller plant and make-up air system. Additionally it was served by only a single electrical supply with no provision for backup power in the event of a power outage. The Data Center operated on a 24 hour per day, year-round cycle, and users had full-hour access to the data center facility. The study found that data center computer load accounted for 15% of the overall building electrical load, while the total power consumption attributable to the data center ...
2007-07-01
International Nuclear Information System (INIS)
A typical form of change in runoff characteristics caused by the widespread use of hydroelectric power in Switzerland is the intermittent draining (torrent operation). It is the aim of the present work to help elucidate possible consequences of these changes in drain onto the benthobiocoenosis. The study was carried through on the Secklisbach at Oberrickenbach (in the semicanton of Nidwalden) and one of its side streamlets (800m above sea level). The macroinvertebrate coenosis was studied at four locations with similar conditions of drainage basin, population density and topography but varying in the degree of impairment to the draining. There were monthly benthos samples taken using a Surber sampling-device. Results show that the locations not only varied in drain, but also in temperature, this being a consequence of water storage by the power plant. The readings pointed out different values for the locations in daily average temperature, day ...
Microgravity two-phase flow regime modeling
Energy Technology Data Exchange (ETDEWEB)
A flow pattern or flow regime is the characteristics spatial distribution of the phases of fluid in a duct. Since heat transfer and pressure drop are dependent on the characteristic distribution of the phases, it is necessary to describe flow patterns in an appropriate manner so that a hydrodynamic or heat transfer theory applicable to that pattern can be chosen. The objective of the present analysis is to create a flow regime map based on physical modeling of vapor/liquid interaction phenomena in a microgravity environment. In the present work, four basic flow patterns are defined: dispersed flow, stratified flow, slug flow, and annular flow. Fluid properties, liquid and vapor flow rates, and pipe size were chosen as the principal parameters. It is assumed that a transition from ...
1987-01-01
Transport of a power plant tracer plume over Grand Canyon National Park
Energy Technology Data Exchange (ETDEWEB)
Meteorological and air-quality data, as well as surface tracer concentration values, were collected during 1990 to assess the impact of Navajo Generating Station (NGS) emissions on Grand Canyon National Park (GCNP) air quality. These data have been used in the present investigation to determine between direct and indirect transport routes taken by the NGS plume to produce measured high-tracer concentration events at GCNP. Results show that complex-terrain features affect local wind-flow patterns during winter in the Grand Canyon area. Local channelling, decoupled canyon winds, and slope and valley flows dominate in the region when synoptic systems are weak. Direct NGS plume transport to GCNP occurs with northeasterly plume-height winds, while indirect transport to the park is caused by wind direction shifts associated with passing synoptic systems. Calculated polluted airmass positions along the modeled streak lines match measured ...
1999-08-01
Energy Technology Data Exchange (ETDEWEB)
The authors investigated the application of pulsed corona discharge process to the removal of SO{sub 2} and NO{sub x} from industrial flue gas of an ioron-ore sintering plant. This study was performed on a pilot scale, which is the most advanced demonstration of this process. The flow rate of 5000 m{sup 3}/h of the flue gas was successfully treated. The electrode structure of the corona reactor is the same with that of conventional electrostatic precipitator. The authors made use of magnetic pulse compression technology to produce repetitive high voltage pulse. Pulse width (full width at half maximum) was reduced to less than 1 {micro}s by connecting a resister in parallel with the corona reactor. An inductor was added to the resister in series to minimize the loss by restricting the current flowing through the resister. By this way, they were able to deliver pulse power with peak voltage of 110 kV and peak current of 2.3 ...
1999-08-01
Energy Technology Data Exchange (ETDEWEB)
This study presents a dynamic analysis of a rotor supported by two turbulent flow model journal bearings and lubricated with couple stress fluid under nonlinear suspension. The dynamics of the rotor center and bearing center is studied. The dynamic equations are solved using the Runge-Kutta method. The analysis methods employed in this study is inclusive of the dynamic trajectories of the rotor center and bearing center, power spectra, Poincare maps and bifurcation diagrams. The maximum Lyapunov exponent analysis is also used to identify the onset of chaotic motion. The results show that the values of dimensionless parameters l* strongly influence dynamic motions of bearing and rotor centre. It is found that couple stress fluid improve the stability of the system when l* > 0.4 even if the flow of this system is turbulent. We also demonstrated that the dimensionless rotational speed ratios s and the dimensionless ...
2008-08-15
International Nuclear Information System (INIS)
This study presents a dynamic analysis of a rotor supported by two turbulent flow model journal bearings and lubricated with couple stress fluid under nonlinear suspension. The dynamics of the rotor center and bearing center is studied. The dynamic equations are solved using the Runge-Kutta method. The analysis methods employed in this study is inclusive of the dynamic trajectories of the rotor center and bearing center, power spectra, Poincare maps and bifurcation diagrams. The maximum Lyapunov exponent analysis is also used to identify the onset of chaotic motion. The results show that the values of dimensionless parameters l* strongly influence dynamic motions of bearing and rotor centre. It is found that couple stress fluid improve the stability of the system when l* > 0.4 even if the flow of this system is turbulent. We also demonstrated that the dimensionless rotational speed ratios s and the dimensionless ...
2008-08-01
Computer programs have been developed to define the temperature increase which would be needed to bring deep-ocean water into density equilibrium with surface water for locations where data are available. A series of continuous-flow studies on phytoplankton blooms resulting from mixtures of 80 percent deep and 20 percent surface water in 2000-liter concrete culturing vessels (''reactors'') has been completed. A quantitative determination of nutrient utilization and flow through a combined primary and secondary trophic level system has been completed. This study utilized the clam Tapes semidecussata, fed from phytoplankton grown in 80 percent deep and 20 percent surface water. An analysis of the fate of the deep water discharged from a floating OTEC plant indicates that horizontal containment of the resulting deep water: surface water mixture is necessary if conditions optimal for open-sea mariculture are to ...
1976-01-01
Four loss-of-flow accidents in the SEAFP first wall/blanket cooling system
Energy Technology Data Exchange (ETDEWEB)
This report presents the thermal-hydraulic analysis of four Loss-of-Flow Accidents (LOFAs) in the first wall/blanket cooling system of the alternative SEAFP reactor design. The LOFAs considered result from a loss of electrical power for the recirculation pump in the primary cooling circuit. The analyses have been performed using the thermal-hydraulic system analysis code RELAP5/MOD3. In the analyses, special attention has been paid to the transient thermal-hydraulic behaviour of the cooling system and the temperature development in the first wall and blanket. For the LOFA without plasma shutdown, significant loss of heat removal due to dryout occurs at the midplane of the outboard first wall cooling pipes about 41 s after pump trip. For the three LOFA cases with emergency plasma shutdown that have been studied, the temperature increase in the Be-coating at the midplane of the outboard first wall is limited to about 30 K. (orig.).
1994-07-01
Formation of Si-nanoparticles in a microwave reactor: Comparison between experiments and modelling
International Nuclear Information System (INIS)
The formation and growth of silicon-nanoparticles from silane in a microwave reactor was investigated. Experiments were performed for the following conditions: precursor concentration 380-2530 ppm, pressures of 20-30 mbar, microwave powers 120-300 W. The formed particles were examined in-situ with a particle mass spectrometer. Additionally, particles were collected on grids and analyzed by transmission electron microscopy, X-ray diffraction, and by determining the specific surface area by BET. The particle size was found to be in the range of 5-8 nm in diameter. A simple model was used to simulate the particle formation processes taking place inside the reactor. The microwave energy coupled into the reactor flow was treated as a spatially distributed energy source resulting in a local temperature increase. The particles were assumed to have a monodisperse size distribution. To allow an approximation of their shape they were characterized by ...
2005-02-01
Feasibility study of a new zinc-air battery concept using flowing alkaline electrolyte
Energy Technology Data Exchange (ETDEWEB)
Proof-of-principle experiments are reported for a new concept in electrically rechargeable zinc-air battery. The zinc electrode is a porous flow-thru type using a copper foam metal substrate with zinc deposition onto the foam metal from concentrated zincate electrolyte (as used in zinc-slurry type batteries). The bifunctional air electrode employs low-cost materials, being fabricated entirely from carbon-based precursors and small amounts of nickel and/or cobalt oxide. Corrosion measurements on the graphite materials in the air electrode indicate sufficient corrosion resistance for 8000 h life on charge. A prototype single cell was constructed having 1.5 Ah capacity producing 1.2 V discharge -2.0 charge at the three hour rate and has produced stable voltages for more than 150 cycles. Based on the 1.5 Ah prototype characteristics, design calculations for a 32 kWh battery project an energy density of about 110 Wh/kg, peak power density of 140 ...
1986-04-01
Energy Technology Data Exchange (ETDEWEB)
The piston bowl design is one of the most important factors that affect the air-fuel mixing and the subsequent combustion and pollutant formation processes in a direct-injection diesel engine. The bowl geometry and dimensions, such as the pip region, bowl lip area, and toroidal radius, are all known to have an effect on the in-cylinder mixing and combustion process. In order to understand better the effect of re-entrant geometry, three piston bowls with different toroidal radii and lip shapes were investigated using computational fluid dynamics engine modelling. KIVA3V with improved submodels was used to model the in-cylinder flows and combustion process, and it was validated on a high-speed direct-injection engine with a second-generation common-rail fuel injection system. The engine's performance, in-cylinder flow, and combustion, and emission characteristics were analysed at maximum power and maximum torque ...
2005-08-15
Climate change and water resources in Britain
International Nuclear Information System (INIS)
This paper explores the potential implications of climate change for the use and management of water resources in Britain. It is based on a review of simulations of changes in river flows, groundwater recharge and river water quality. These simulations imply, under feasible climate change scenarios, that annual, winter and summer runoff will decrease in southern Britain, groundwater recharge will be reduced and that water quality - as characterised by nitrate concentrations and dissolved oxygen contents - will deteriorate. In northern Britain, river flows are likely to increase throughout the year, particularly in winter. Climate change may lead to increased demands for water, over and above that increase which is forecast for non-climatic reasons, primarily due to increased use for garden watering. These increased pressures on the water resource base will impact not only upon the reliability of water supplies, but also upon navigation, aquatic ...
1998-05-01
A relativistic mixing-layer model for jets in low-luminosity radio galaxies
We present an analytical model for jets in Fanaroff & Riley Class I (FRI) radio galaxies, in which an initially laminar, relativistic flow is surrounded by a shear layer. We apply the appropriate conservation laws to constrain the jet parameters, starting the model where the radio emission is observed to brighten abruptly. We assume that the laminar flow fills the jet there and that pressure balance with the surroundings is maintained from that point outwards. Entrainment continuously injects new material into the jet and forms a shear layer, which contains material from both the environment and the laminar core. The shear layer expands rapidly with distance until finally the core disappears, and all of the material is mixed into the shear layer. Beyond this point, the shear layer expands in a cone and decelerates smoothly. We apply our model to the well-observed FRI source 3C31 and show that there is a self-consistent solution. We derive ...
2009-01-01
International Nuclear Information System (INIS)
CANDU 600 nuclear reactors are usually fuelled with STANDARD (STD), 37 rods fuel bundles. Natural uranium (NU) dioxide (UO_2), is used as fuel composition. A new fuel bundle geometry called CANFLEX (CFX) with 43 rods is proposed and some new fuel composition are considered. Flexibility is the key word for the attempt to use some different fuel geometries and compositions for CANDU 600 nuclear reactors as well as for innovative ACR-700/1000 nuclear reactors. The fuel bundle considered in this paper is CFX-RU-0.90 that encodes the CANFLEX geometry, recycled dioxide uranium (RU) with 0.90% enrichment. The goal of this proposal is ambitious: a higher average discharge burn-up up to 14000 MWd/tU and, for the same amount of generated electric power, reduction in nuclear fuel fabrication, reduction of spent nuclear fuel radioactive waste and reduction of refueling operational work by using fewer bundles. An improved sub-channel approach for thermal-hydraulic analysis is ...
2007-11-22
HST/ACS observations of shell galaxies: inner shells, shell colours and dust
AIM:Learn more about the origin of shells and dust in early type galaxies. METHOD: V-I colours of shells and underlying galaxies are derived, using HST Advanced Camera for Surveys (ACS) data. A galaxy model is made locally in wedges and subtracted to determine shell profiles and colours. We applied Voronoi binning to our data to get smoothed colour maps of the galaxies. Comparison with N-body simulations from the literature gives more insight to the origin of the shell features. Shell positions and dust characteristics are inferred from model galaxy subtracted images. RESULT: The ACS images reveal shells well within the effective radius in some galaxies (at 1.7 kpc in the case of NGC 5982). In some cases, strong nuclear dust patches prevent detection of inner shells. Most shells have colours which are similar to the underlying galaxy. Some inner shells are redder than the galaxy. All six shell galaxies show out of dynamical equilibrium dust ...
2007-01-01
British Library Electronic Table of Contents (United Kingdom)
Previous research utilizing the AcB/BcA recombinant congenic strains (RCS) of mice mapped provisional quantitative trait loci (QTLs) for the psychostimulant effects of nicotine to multiple regions on chromosomes 7, 11, 12, 14, 16, and 17. The current study was designed to confirm these QTLs in an A/J (A)??C57Bl/6J (B6) F2 cross and a panel of B6.A chromosome substitution strains (CSS). The panel of B6.A CSS consists of 21 strains, each carrying a different A/J chromosome on a B6 background. The A??B6 F2, CSS, A, and B6 mice were tested for sensitivity to the effects of nicotine on locomotor activity using a computerized open-field apparatus. In A??B6 F2 mice two QTLs were identified which confirm those previously observed in the AcB/BcA RCS. Significant differences in the expression of ...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
For the purpose of proposing it to ISO, the R and D were conducted of a new evaluation method of thermal properties of polymer materials. The FY 1999 results were summarized. In this fiscal year, the development of the ac Joule heating equipment was proceeded with based on the study at the technical committee, and the measuring device was installed. In the comparative measurement with conventional methods, study was proceeded with of the laser flash method, AC calorimetry method and specific heat measurement. In the technical survey, the developmental state of the ac method, especially, was examined as a testing method of thermal properties of polymer materials. It is in the stage of the basic research by keyword selection, and the search for literature is to be made in full scale. As to the needs in the industrial circle, as a result of the questionnaire survey made, it was found out that there were a wide variety of the ...
2000-03-01
Energy Technology Data Exchange (ETDEWEB)
This thesis surveys the concepts of exergy and extends the exergy method of analysis from the standpoint of its applications to the power plant systems. After a brief historical review of exergy concepts, the general exergy equation is derived from the combined equation of First and Second Law, and it is shown that any special case of exergy equation is a simplified form of the general exergy equation. The mathematical method for the exergy analysis of a steady-state, steady-flow system, analogous to that of the First Law, is given. The exergy losses in a power plant are discussed. Then in order to examine these losses, the Second Law performance of major processes of combustion, compression, heat transfer, mixing and throttling have been analyzed analytically, and the exergy efficiencies are defined that accurately assess the thermodynamic performance of the corresponding processes. The methods for computation of exergy ...
1981-01-01
International Nuclear Information System (INIS)
Previous flow regime studies have been for horizontal, vertical, and inclined pipe flow. As such, only a few studies have been performed on bundle geometries. The present paper examines the flow regimes for a vertical hexagonal flow channel with and without a finned fuel bundle. This type of a 36 finned rod hexagonal fuel bundle in parallel hexagonal flow channels is used in a MAPLE (Multi- purpose Applied Physics Lattice Experimental) type nuclear reactor. An experiment apparatus was designed consisting of the flow channel, inlet plenum and an air-water separator. The inlet plenum is used to provide a uniform mixture of air and water before entering the hexagonal flow channel. A turbine flow meter is used to determine the water flow rate. The turbine flow meter is calibrated for ...
1990-12-10
The effect of patient positioning aids on PET quantification in PET/MR imaging
British Library Electronic Table of Contents (United Kingdom)
Objectives Clinical PET/MR requires the use of patient positioning aids to immobilize and support patients for the duration of the combined examination. Ancillary immobilization devices contribute to overall attenuation of the PET signal, but are not detected with conventional MR sequences and, hence, are ignored in standard MR-based attenuation correction (MR-AC). We report on the quantitative effect of not accounting for the attenuation of patient positioning aids in combined PET/MR imaging. Methods We used phantom and patient data acquired with positioning aids on a PET/CT scanner (Biograph 16, HI-REZ) to mimic PET/MR imaging conditions. Reference CT-based attenuation maps were generated from measured (original) CT transmission images (origCT-AC). We also created MR-like attenuation map...
2011-01-01
The VOISE Algorithm: a Versatile Tool for Automatic Segmentation of Astronomical Images
The auroras on Jupiter and Saturn can be studied with a high sensitivity and resolution by the Hubble Space Telescope (HST) ultraviolet (UV) and far-ultraviolet (FUV) Space Telescope spectrograph (STIS) and Advanced Camera for Surveys (ACS) instruments. We present results of automatic detection and segmentation of Jupiter's auroral emissions as observed by HST ACS instrument with VOronoi Image SEgmentation (VOISE). VOISE is a dynamic algorithm for partitioning the underlying pixel grid of an image into regions according to a prescribed homogeneity criterion. The algorithm consists of an iterative procedure that dynamically constructs a tessellation of the image plane based on a Voronoi Diagram, until the intensity of the underlying image within each region is classified as homogeneous. The computed tessellations allow the extraction of quantitative information about the auroral features such as mean intensity, latitudinal and longitudinal ...
2009-01-01
Multiphase flow calculation software
Energy Technology Data Exchange (ETDEWEB)
Multiphase flow calculation software and computer-readable media carrying computer executable instructions for calculating liquid and gas phase mass flow rates of high void fraction multiphase flows. The multiphase flow calculation software employs various given, or experimentally determined, parameters in conjunction with a plurality of pressure differentials of a multiphase flow, preferably supplied by a differential pressure flowmeter or the like, to determine liquid and gas phase mass flow rates of the high void fraction multiphase flows. Embodiments of the multiphase flow calculation software are suitable for use in a variety of applications, including real-time management and control of an object system.
2003-04-15
Energy Technology Data Exchange (ETDEWEB)
By applying the mass, momentum, and angular momentum conservation laws and the maximum flow rate principle to swirling, effectively inviscid, incompressible flows in a circular tube with a sudden expansion and the direct-flow and reversed-flow Borda mouthpieces the dependence of the flow rate coefficient and mechanical energy losses on the radius ratio and nondimensional circulation is obtained. Several calculating approaches with potential and helical motion are introduced and investigated. In the case of helical motion, as the swirl decreases the axial core of the flow is found to close with a sudden change of the flow parameters.
1994-11-01
WWER steam generator transients during loss of coolant accidents
International Nuclear Information System (INIS)
A nonlinear mathematical model is presented of a WWER-440 nuclear power plant horizontal steam generator. On the proposed model is based a computer program for investigating transients in steam generators during loss of coolant accidents. Processes taking place at the primary side of the steam generator are described by a set of partial differential equations while those at the secondary side of the steam generator are described by plain differential equations with the variables being complex time functions. The model takes account of the coolant as both a single- and two-phase medium, of changes in the direction of the primary coolant flow and of changes in the direction of heat transfer. Heat transfer through the wall is based on a simple model of heat transfer through a thin-walled tube and includes a correction for the heat resistance of the wall. (author).
1978-01-01
The roles and electrochemical characterizations of activated carbon in zinc air battery cathodes
Energy Technology Data Exchange (ETDEWEB)
We prepared cathodes with various types of activated carbon and measured the cathodes' electrochemical performance according to the kind of activated carbon. Activated carbon supplies airflow channels and reaction sites in the cathode of zinc air batteries. When we use activated carbon with a high specific surface area as the cathode's catalyst substrate, we expect high electrochemical performance because this type of carbon provides more air flow channels and reaction sites. We focused on investigating the relationship between the cathode's pore structure and its electrochemical characterizations. We also studied the effects of the various activated carbon materials on the zinc air batteries' performance. Increasing the macropores or mesopores in the activated carbon resulted in achieving more power from the battery. (author)
2006-12-01
Space reactor fuel element testing in upgraded TREAT
Energy Technology Data Exchange (ETDEWEB)
The testing of candidate fuel elements at prototypic operating conditions with respect to temperature, power density, hydrogen coolant flow rate, etc., a crucial component in the development and qualification of nuclear rocket engines based on the Particle Bed Reactor (PBR), NERVA-derivative, and other concepts. Such testing may be performed at existing reactors, or at new facilities. A scoping study has been performed to assess the feasibility of testing PBR based fuel elements at the TREAT reactor. initial results suggest that full-scale PBR, elements could be tested at an average energy deposition of {approximately}60--80 MW-s/L in the current TREAT reactor. If the TREAT reactor was upgraded to include fuel elements with a higher temperature limit, average energy deposition of {approximately}100 MW/L may be achievable.
1993-05-01
British Library Electronic Table of Contents (United Kingdom)
A non-similar boundary layer analysis is presented to study the flow, heat and mass transfer characteristics of non-Darcian mixed convection of a non-Newtonian fluid from a vertical isothermal plate embedded in a homogeneous porous medium with the effect of Soret and Dufour and in the presence of either surface injection or suction. The value of the mixed-convection parameter lies between 0 and 1. In addition, the power-law model is used for non-Newtonian fluids with exponent n1 for dilatant fluids. Furthermore, the coordinates and dependent variables are transformed to yield computationally efficient numerical solutions that are valid over the entire range of mixed convection, from the pure forced-convection limit to the pure free-conve...
2010-01-01
Safety considerations of active process water system shutdown for TAPP - 3 and 4
International Nuclear Information System (INIS)
Active Process Water (APW) System, provided as unitized closed loop system in Tarapur Atomic Power Project Units-3 and 4, serves to remove heat from various heat exchangers. One of the important loads served by APW system is shutdown cooling heat exchangers and if APW shutdown is taken then reactor cannot be maintained in cold shutdown condition. It is estimated that after 7 days of reactor shutdown, if about 20% of the normal cooling flow to shutdown cooling heat exchangers is provided then along with keeping PHT in cold shutdown state, reactor components, moderator, end shield water, calandria vault water and calandria vault concrete temperature can be maintained within technical specification limits for extended duration. (author)
2005-12-01
Reflux boiling heat removal in a scaled TMI-2 system test facility
International Nuclear Information System (INIS)
An investigation of decay heat removal by the reflux boiling process was performed on a 1/18 linear-scaled test facility simulating the Three Mile Island (TMI-2) primary system. The objective was to clarify reflux boiling phenomena and core cooling effectiveness. Principal test variables included: core power, primary system water and gas inventories, and steam generator secondary-side coolant flow rate. Of 49 tests conducted, 43 achieved a steady-state heat rejection mode within 3 hours. Subsequent analyses identified two distinct reflux boiling modes. Based upon our current understanding, reflux boiling appears to be an effective process for removing decay heat in a broad range of the conditions investigated for a plant of the TMI configuration.
1980-06-01
Radiation hardening of smart electronics
International Nuclear Information System (INIS)
Microprocessor based ''smart'' pressure, level, and flow transmitters were tested to determine the radiation hardness of this class of electronic instrumentation for use in reactor building applications. Commercial grade Complementary Metal Oxide Semiconductor (CMOS) integrated circuits used in these transmitters were found to fail at total gamma dose levels between 2500 and 10,000 rad. This results in an unacceptably short lifetime in many reactor building radiation environments. Radiation hardened integrated circuits can, in general, provide satisfactory service life for normal reactor operations when not restricted to the extremely low power budget imposed by standard 4--20 mA two-wire instrument loops. The design of these circuits will require attention to vendor radiation hardness specifications, dose rates, process control with respect to radiation hardness factors, and non-volatile programmable memory technology. 3 refs., 2 figs.
Energy Technology Data Exchange (ETDEWEB)
Currently the construction of small-scale hydroelectric and pumped storage plants is booming in the USA. The technology is attractive because of its relatively cheap construction methods and operation. Electric utilities are seeing it as a viable source of peaking power and a means of system regulation. Two schemes are described. One is a high-head/small flow river project designed to generate 3.5 MW and is about to come on line having overcome tight environmental and commercial constraints. The second is a pumped-storage project using two man-made reservoirs with an average elevation difference of 1280 ft. It is deemed to be of minimum environmental impact construction and good physical characteristics. Completion is hoped for by 1995 and the plant will deliver 1000 MW. (UK)
1994-04-01
On the evolution of supernova remnants: Pt. 2
International Nuclear Information System (INIS)
Supernova explosions within wind-driven bubbles are studied with 2D hydrodynamical calculations. Two different density distributions for the ejecta are considered: (i) a smooth, unfragmented power-law stratification, and (ii) a fragmented distribution. As in 1D models, the presence of the shell of interstellar swept-up matter causes the rapid evolution of the remnant to the radiative phase. The main 2D effects, for both fragmented and unfragmented ejecta, include: (i) substantial chaotic deviations from a purely radial flow in the remnant interior, (ii) efficient turbulent mixing between the ejecta and the shocked wind, resulting in homogenization of the former wind cavity, and (iii) severe distortion of the wind-driven shell by cooling and Rayleigh-Taylor instabilities. (author).
New technology for purging the steam generators of nuclear power plants
British Library Electronic Table of Contents (United Kingdom)
A technology for removal of undissolved impurities from a horizontal steam generator using purge water is developed on the basis of a theoretical analysis. A purge with a maximal flow rate is drawn off from the zone with the highest accumulation of sludge in the lower part of the steam generator after the main circulation pump of the corresponding loop is shut off and the temperatures of the heat transfer medium at the inlet and outlet of the steam generator have equilibrated. An improved purge configuration is used for this technology; it employs shutoff and regulator valves, periodic purge lines separated by a cutoff fixture, and a D y 100 drain union as a connector for the periodic purge. Field tests show that the efficiency of this technology for sludge removal by purge water is severa...
2011-01-01
Modeling of lean premixed combustion in stationary gas turbines
Energy Technology Data Exchange (ETDEWEB)
Lean premixed combustion (LPC) of natural gas is of considerable interest in land-based gas turbines for power generation. However, modeling such combustors and adequately addressing the concerns of LPC, which include emissions of nitrogen oxides, carbon monoxide and unburned hydrocarbons, remains a significant challenge. In this paper, characteristics of published simulations of gas turbine combustion are summarised and methods of modeling turbulent combustion are reviewed. The velocity-composition PDF method is selected for implementation in a new comprehensive model that uses an unstructured-grid flow solver. Reduced mechanisms for methane combustion are evaluated in a partially stirred reactor model. Comprehensive model predictions of swirl-stabilised LPC of natural gas are compared with detailed measurements obtained in a laboratory-scale combustor. The model is also applied to industrial combustor geometries. (Author)
1999-07-01
Machine condition monitoring - the way ahead
Energy Technology Data Exchange (ETDEWEB)
During the last fifteen years a variety of instruments and transducers, such as voltage plugs, power transducers, flow and pressure transducers, recorders and tensometers, have been developed for underground use in measuring the performance and technical parameters of prototype machines. The equipment, until recently, has been in a portable form and was found useful by the industry generally, in fault finding and trouble-shooting exercises and in commissioning procedures performed by small teams on a call-out basis. Over the last five years the test equipment has been adapted and the techniques modified to suit individual colliery-based operations with more permanent machine mounted and built-in transducers. At the moment these techniques operate within the framework of a statutory planned preventive maintenance scheme for each mine. This paper discusses the merits of changing from preventive maintenance to condition-based maintenance and the ...
1984-11-01
Jacobi stability analysis of dynamical systems -- applications in gravitation and cosmology
The Kosambi-Cartan-Chern (KCC) theory represents a powerful mathematical method for the analysis of dynamical systems. In this approach one describes the evolution of a dynamical system in geometric terms, by considering it as a geodesic in a Finsler space. By associating a non-linear connection and a Berwald type connection to the dynamical system, five geometrical invariants are obtained, with the second invariant giving the Jacobi stability of the system. The Jacobi (in)stability is a natural generalization of the (in)stability of the geodesic flow on a differentiable manifold endowed with a metric (Riemannian or Finslerian) to the non-metric setting. In the present paper we review the basic mathematical formalism of the KCC theory, and present some specific applications of this method in general relativity, cosmology and astrophysics. In particular we investigate the Jacobi stability of the general relativistic static fluid sphere with a ...
2010-01-01
Incorporation of organizational failures in PSA
International Nuclear Information System (INIS)
A large portion of the work performed at nuclear power plants follows standardized flow paths. For example, although components on which the maintenance crew works differ from one assignment to the next, all assignments basically follow the same process: requesting, reviewing, planning, scheduling, executing, testing, and documenting the work. In general, the term open-quotes work processclose quotes is used to refer to a standardized sequence of tasks designed within the operational environment of an organization to achieve a specific goal. The predictable nature of work processes suggests that a systematic analysis can be conducted to identify the desirable design of the process and to develop performance measures with respect to the strengths and weaknesses in the process. Furthermore, because of the close relationship of the work process to plant performance and plant safety, it is believed that such an analysis will facilitate the ...
1993-06-20
High temperature deformation of the Al-5Cr-2Zr alloy as a function of powder particle diameter
International Nuclear Information System (INIS)
The powder particle size, D, influences the creep behaviour of Al-Cr-Zr alloys. The alloy studied in this work, Al-5Cr-2Zr (mass%), was prepared by argon atomization. Three size fractions of powder particles were selected: 24-50 #mu#m, 50-100#mu#m and 100-200 #mu#m in diameter. They were consolidated by extrusion. Independently of D, the flow behaviour of the alloy can be described by the power law equation. As test temperature increases, the stress exponent n decreases up to a value close to 5. A decrease of D causes an increase of n and delays the alloy degradation at high temperature. (Author) 11 refs.
1998-01-01
Electric utilities have been surprised by recent opposition to the construction of very-high-voltage transmission lines, which met with little resistance in the past. Concerns over health and safety factors are associated with the increase in the number of such lines, although their presence has always been an inconvenience and a hazard for those living and working in the immediate vicinity. The new lines present additional hazards due to the continuous flow of small electric currents and the charges that build up in the area of the towers and lines. The lines are also a threat to persons wearing cardiac pacemakers. There is experimental evidence from the Soviet Union and the U.S. that electric and magnetic fields at the frequencies of such power lines can have serious biological effects on growth rates and the functioning of the central nervous system. Full disclosure that possible risks are involved and the opportunity to avoid these risks is ...
1978-05-01
Chicken runs provide the fuel for Fibrowatt's global ambitions
Energy Technology Data Exchange (ETDEWEB)
This article reports on the operation of Fibrowatt's third chicken waste-fuelled power plant at Thetford in Norfolk, UK. Details are given of the plant which started operation in October 1998, the chicken litter fuel, the spiral screw fuel feeders, the Detroit Stoker grate and spreader stokers which ensure the fuel is burnt mid-air, the production of fertiliser from the ash, and fluegas emission control using cyclones, a baghouse and lime addition to neutralise acid gas. The economics of the project, and the support for the renewable electricity generation under the UK government's Non-Fossil Fuel Obligation are discussed. A site plan of the Thetford plant and a flow diagram of the process are provided.
2000-08-01
International Nuclear Information System (INIS)
The report presents the results of experimental studies conducted to provide a description of the conditions which lead to the occurrence of critical heat flux (CHF), in Combustion Engineering (C-E) fuel assemblies using the C-E standard spacer grid. A CHF correlation is presented which is based on CHF data obtained in tests with electrically heated rod bundles representative of the C-E 14 x 14 and 16 x 16 array fuel assemblies. The results reported are for a uniform axial heat flux distribution. The experiments were conducted in the Medium Pressure Heat Transfer Flow Loop at the Chemical Engineering Research Laboratories at Columbia University.
Absorption of carbon dioxide in waste tanks
International Nuclear Information System (INIS)
Air flow rates and carbon dioxide concentrations of air entering and exiting eight H-Area waste tanks were monitored for a period of one year. The average instanteous concentration of carbon dioxide in air is within the range reported offsite, and therefore is not affect by operation of the coal-fired power plant adjacent to the tank farm. Waste solutions in each of the tanks were observed to be continuously absorbing carbon dioxide. The rate of absorption of carbon dioxide decreased linearly with the pH of the solution. Personnel exposure associated with the routine sampling and analysis of radioactive wastes stored at SRP to determine the levels of corrosion inhibitors in solution could be reduced by monitoring the absorption of carbon dioxide and using the relationship between pH and carbon dioxide absorption to determine the free hydroxide concentration in solution.
1987-09-01
ARIES-AT safety design and analysis
British Library Electronic Table of Contents (United Kingdom)
ARIES-AT is a 1000MWe conceptual fusion power plant design with a very low projected cost of electricity. The design contains many innovative features to improve both the physics and engineering performance of the system. From the safety and environmental perspective, there is greater depth to the overall analysis than in past ARIES studies. For ARIES-AT, the overall spectrum of off-normal events to be examined has been broadened. They include conventional loss of coolant and loss of flow events, an ex-vessel loss of coolant, and in-vessel off-normal events that mobilize in-vessel inventories (e.g., tritium and tokamak dust) and bypass primary confinement such as a loss of vacuum and an in-vessel loss of coolant with bypass. This broader examination of accidents improves the robustness of ...
2006-01-01
Energy Technology Data Exchange (ETDEWEB)
A three dimensional sea-land breeze model and lagrangian particle dispersion model have been employed for the study on the mesoscale atmospheric dispersion of radioactive materials released from Wolsung NPPs. In this study, atmospheric dispersion simulations are carried out under two synoptic weather conditions: the geostrophic flow is a weak northerly wind (CASE 1) and a strong northerly wind (CASE 2) on a clear day in spring. The results show that atmospheric dispersion is affected by sea-land breeze and the recirculation of particles by the change of wind direction between sea breeze and land breeze plays an important role in atmospheric concentration distribution of radioactive materials.
1997-12-01
A comparison between steam injection cycle and combined cycle by energy balance
International Nuclear Information System (INIS)
This paper reports on steam injection cycle which is similar to supplementary fired combined cycle, but for the utilized steam medium produced by HRSG, its temperature is higher and pressure is lower than in the combined cycle. In comparison with the thermodynamic advantage of the two cycles, a clear understanding of physical concept can be gotten simply by energy balance. The difference of total power output between them is subtraction of enthalpy difference of exhaust steam and feed water of HRSG in steam injection cycle from the rejected heat by water coolant of condenser in combined cycle, when using the identical gas turbine and the same amount of total fuel consumption. In general case, formulas and data are given to indicate this comparison by the ratio of steam mass flow supplied by HRSG of the two cycles. The analysis of Cheng Cycle Series 7 is applied as an example to give the practical result.
1989-06-05
A He-gas Cooled, Stationary Granular Target
In the CERN approach to the design of a neutrino factory, the repetition frequency of the proton beam is high enough to consider stationary solid targets as a viable solution for multi-MW beams. The target consists of high density tantalum spheres of 2 mm diameter which can efficiently be cooled by passing a high mass flow He-gas stream through the voids between the Ta-granules. Very small thermal shocks and stresses will arise in this fine grained structure due to the relatively long burst of 3.3 ms from the SPL-proton linac. In a quadruple target system where each target receives only one quarter of the total beam power of 4 MW, conservative temperature levels and adequate lifetimes of the target are estimated in its very high radiation environment. A conceptual design of the integration of the target into the magnetic horn-pion-collector is presented.
2003-01-01
Application of the porous media model for the LWR process components
Energy Technology Data Exchange (ETDEWEB)
Full text of publication follows: A porous media solution PORFLO has been developed for the 3-dimensional two-phase flow by describing the process facility in Cartesian or cylindrical coordinates. The local porosity fraction is applied for distinguishing the fluid filled volumes from the solid structures. The solid structure contribute the two-phase flow through the wall friction, flow area and heat transfer. Optionally the solid structure may contain primary liquid of steam generators, steam in the higher temperature and pressure to be condensed or electrical heating power. By using these optional boundary conditions three different process facilities have been analysed. The thermohydraulic solution based on 5-equation approach, where the conservation equations are solved for the liquid and gas (vapour) mass, mixture momentum (giving the velocity only for the mixture), liquid and gas energy, is ...
2005-07-01
Wind Tunnel Flow Quality and Data Accuracy Requirements
... tests, one often encounters, for instance, separated flows with large ... It is suspected that the flow-quality criteria given in AGARD Report No. ...
1982-11-01
... percent by interbasin ground-water flow into the Hueco Bolson, and 2 percent by flow into creeks and ... ...
RESEARCH ON FLOW SEPARATION IN WESTERN EUROPE
... Separation," AGARD,Rept 272, April 1960, ... Leading Edge Effect on Supersonic Boundary Layer Flow." ... of Gas Injection in Separated Flows." TCEA, ...
1963-07-01
Perfect and Incompressible Fluid Flow in Turbomachines.
A method for calculating flow through an airfoil cascade drawn on a surface of revolution is discussed. The three-dimensional flow was assumed to be represented by part-channels of varying width. The basic equations are the equation of continuity and the ...
1974-01-01
Large Eddy Simulation of Supersonic Turbulent Flow in ...
... AGARD AR-319, Volume 2. Knight, D., Zhou ... a Turbulent Boundary Layer in a Supersonic Flow. ... of Development of Separated Flows in Compression ...
2001-08-01
Free Shear Layers, Base Pressure and Bluff-Body Drag
... In: Separated Flows, AGARD CP No. ... on thin wings in two-dimensional incompressible flow. ... fields in the region of separating and reattaching flows. ...
1993-12-10
Control of Flow Separation Using Adaptive Airfoils
... been demonstrated in steady compressible flows. ... steady Compressible Flow on an Oscillating Airfoil ... of Oscillating Airfoils", AGARD-CP-552, Aug. ...
1997-01-01
Calculation and Measurement of Transonic Flows over ...
... including those with rear separation, ... flows ibout airfoils." AIAA Paper 'Jo 97-0419, 1987). ... "Effects of streamline curvature on turbulent flow." AGARD ...
1988-10-01
Asymmetric Vortex Flow Over Circular Cones
... Calculations of asymmetric separated flow past circular ... in Missile Aerodynamics, AGARD CP 336 ... three-dimensional vortex flows in aerodynamics. ...
1991-03-01
Application of Synthetic Jets to Reduce Stator Flow Separation in a ...
Surface pressure measurements at mid span indicate that flow separation begins near ..... Turbomachinery Flows, AGARD Propulsion Energetics Panel, 1998. ...
A Simple Model of Vortex Flow Past a Slender Elliptic Cone at ...
... Calculations of asymmetric separated flow past circular ... in Missile Aerodynamics, AGARD-CP-336 ... Marconi Asymmetric separated flows about sharp ...
1990-09-01
Energy Technology Data Exchange (ETDEWEB)
The two-phase flow program is directed at understanding the hydrodynamics of two-phase flows. The two-phase flow regime is characterized by a series of flow patterns that are designated as bubble, slug, churn, and annular flow. Churn flow has received very little scientific attention. This lack of attention cannot be justified because calculations predict that the churn flow pattern will exist over a substantial portion of the two-phase flow zone in producing geothermal wells. The University of Houston is experimentally investigating the dynamics of churn flow and is measuring the holdup over the full range of flow space for which churn flow exists. These experiments are being conducted in an air/water vertical two-phase flow loop. Brown ...
1983-12-01
The fate of trace elements at coal-fired power plants
International Nuclear Information System (INIS)
Within the framework of a Dutch research program on the environmental effects of coal combustion 15 measuring campaigns were carried out in the eighties. All the relevant ingoing and outgoing flows of electric power plants were sampled and the heavy metals composition was determined. An overview is given of these fifteen measuring campaigns. It is concluded that between 99.7% and 99.9% of the fly ash can be separated by electrofilters. The removal of solid elements is higher than 99%, except for those elements, which are enriched in the fly ash, f.e. Cd and Se (>90% removal is possible). Additional separation of the emissions of fly ash and elements in the fly ash takes place in a flue gas desulfurization (FGD) installation. Some elements are emitted as gaseous wastes. After the electrofilter Cl, F and I can be found for almost 100%, Br and Hg for 50% on average, and only small amounts of As and Se in the gaseous phase. In a wet FGD unit ...
Series fan-powered boxes: Their impact on indoor air quality and comfort
Energy Technology Data Exchange (ETDEWEB)
Until the concerns about indoor air quality (IAQ) reached a peak in the last five years, interior zones of office buildings were traditionally served with cooling-only shut-off variable air volume (VAV) boxes. Heat gains from lighting and equipment, in addition to those from occupants themselves, caused supply air quantities of 13 C to 15 C (55 F to 60 F) air to be sustained at rates on the order of 2.5 L/s per square meter (0.5 cfm per square feet), a rate that most designers at the time felt would provide a comfortable and well ventilated environment. More recently, the reduction in lighting loads, the use of cold air systems, and, most importantly, the concern that acceptable indoor air quality may not be maintained at low air flow rates, has led to a different solution in interior zones: the series fan-powered mixing box.
1996-07-01
Nomographs for H[sub 2]O-LiBr absorption-panel cooling systems
Energy Technology Data Exchange (ETDEWEB)
Panel cooling of buildings offers energy savings over conventional space-cooling systems. We present a procedure for calculating the performance of H[sub 2]O-LiBr absorption-panel cooling systems, in which the evaporator is the panel itself. Nomographs have been developed for this approach. Under the conditions examined, the H[sub 2]O-LiBr absorption unit operates with a theoretical performance coefficient of about 90% and with a practically constant specific cooling capacity of 2394 kJ/kg H[sub 2]O. For common values of the parameters involved, the panel cooling power varies from 25 to 175 W/m[sup 2] and the cooling water mass-flow through the panel is 40-260 g/m[sup 2]h. The thermal power needed to drive the system varies from 27 to 200 W/m[sup 2] and the associated temperatures from 70 to 100[sup o]C; thus, the system may be operated on solar energy. (Author).
1992-11-01
Liquid zone system events at Wolsong Unit 2
International Nuclear Information System (INIS)
On June 19, 1998, after the first annual outage, Wolsung Unit 2 was shutdown at a controlled rate due to the continuous instability of Liquid Zone Control level. Investigation revealed that the Liquid Zone Control level instability was caused by water condensed inside the helium lines, generated from the moistened helium flow, especially, inside the helium balance header feed and bleed valve lines. It was found that improper installation of the diaphragm type isolation valves and the drain valve tap could easily contain the water inside the lines and be destined to form water traps causing the balance header pressure oscillation. After the lines were dried, Liquid Zone Control level instability was almost vanished, and approached the allowable equilibrium state. As the reactor power was increased, however, the zone level instability increased again. In order to compensate for the excessive, the Bulk Power Control Gain (Kp) ...
1998-09-07
International Nuclear Information System (INIS)
Ozone formation by a pulse positive corona discharge generated in the gas phase between a planar high voltage electrode made from reticulated vitreous carbon and a water surface with an immersed ground stainless steel plate electrode was investigated under various operating conditions. The effects of gas flow rate (0.5-3 litre min"-"1), discharge gap spacing (2.5-10 mm), applied input power (2-45 W) and gas composition (oxygen containing argon or nitrogen) on ozone production were determined. Ozone concentration increased with increasing power input and with increasing discharge gap. The production of ozone was significantly affected by the presence of water vapour formed through vaporization of water at the gas-liquid interface by the action of the gas phase discharge. The highest energy efficiency for ozone production was obtained using high voltage pulses of approximately 150 ns duration in Ar/O_2 mixtures with the ...
2005-02-07
Design of electron beam accelerators for microwave application
Energy Technology Data Exchange (ETDEWEB)
Relativistic electron beams are used for generating high power microwaves. These microwave sources require electron beam generators spanning significant ranges in voltage and impedance. The pulsed power technology used to generate these electron beams is presented. Electron beam generators that produce beams with pulse durations in the 10-ns to 100-ns regime consist of an energy-storage section, pulse-shaping section, and an electron beam diode. The energy-storage section is either a Marx generator or capacitor bank-pulsed transformer. The pulse shaping is done with high-voltage transmission lines. The electron beam diode is usually a cold-cathode, space-charge-limited flow device. For longer pulses (/approximately/1 ..mu..s) the energy storage and pulse chaping can be combined. Lumped-element pulse-forming networks (PFN) can be designed to produce the desired pulse shape. The Marx generator becomes one of the elements of ...
1988-07-01
Design of electron beam accelerator for microwave application
Energy Technology Data Exchange (ETDEWEB)
Relativistic electron beams are used for generating high power microwaves. These microwave sources require electron beam generators spanning significant ranges in voltage and impedance. The pulsed power technology used to generate these electron beams is presented. Electron beam generators that produce beams with pulse durations in the 10 ns to 100 ns regime consist of an energy storage section, pulse shaping section, and an electron beam diode. The energy storage section is either a Marx generator or capacitor bank-pulsed transformer. The pulse shaping is done with high-voltage transmission lines. The electron beam diode is usually a cold-cathode, space-charge-limited flow device. For longer pulses (approx.1 ..mu..s) the energy storage and pulse shaping can be combined. Lumped-element pulsed-forming networks (PFN) can be designed to produce the desired pulse shape. The Marx generator becomes one of the elements of the PFN. ...
1988-01-01
Conceptual fusion power monitor based on the "1"6O(n,p)"1"6N reaction
International Nuclear Information System (INIS)
The feasibility of developing a fusion power monitor based on a fluid activation detector is considered here. The activation fluid may be either a liquid or a gas and its composition can be selected from a number of candidate materials to provide desired activation and decay characterisitcs. Performance calculations indicate that ordinary water would be a nearly ideal activation fluid. The "1"6O(n,p)"1"6N reaction has a threshold at about 10 MeV and a cross section energy dependence giving it a predominant response for unmoderated D-T fusion neutrons. Adequate activation can be obtained at moderate flow rates for remote counting away from the high radiation area of the reactor. The 7.16 sec half-life of "1"6N is ideal for remote counting with subsequent decay in a small hold-up tank to eliminate activity build-up in the recycled water.
1981-07-01
Carmanah Technologies Corporation 2004 annual report
International Nuclear Information System (INIS)
British Columbia-based Carmanah Technologies is a world leader in the design, manufacture and supply of patented solar-powered light emitting diode (LED) lighting solutions. As a leading alternative energy manufacturer, it was the first company to integrate LEDs with solar chargers and battery power storage. Carmanah products have high-end assembly, minimal size, maximized performance and field-proven reliability. The products have been used in public transit applications, roadway lighting, and for general aviation lighting solutions. In 2004, their products saved the equivalent of 6,705 metric tonnes of carbon dioxide. This annual report includes information on the company's net earnings and investor profiles. The company has large markets for its products with little competition. It has a strong management team and its funding places it in a position to capitalize on current and emerging technologies. The company's energy resource activities ...
2005-01-01
Energy Technology Data Exchange (ETDEWEB)
A unified model is presented for a class of combined energy systems, in which the systems mainly consist of a heat engine, a combustor and a counter-flow heat exchanger and the heat engine in the systems may have different thermodynamic cycle modes such as the Brayton cycle, Carnot cycle, Stirling cycle, Ericsson cycle, and so on. Not only the irreversibilities of the heat leak and finite-rate heat transfer but also the different cycle modes of the heat engine are considered in the model. On the basis of Newton's law, expressions for the overall efficiency and power output of the combined energy system with an irreversible Brayton cycle are derived. The maximum overall efficiency and power output and other relevant parameters are calculated. The general characteristic curves of the system are presented for some given parameters. Several interesting cases are discussed in detail. The results obtained here are very ...
2009-06-15
Energy Technology Data Exchange (ETDEWEB)
Economic and safe operation of nuclear power plants requires reliable steam turbines with high efficiencies. The progress in flow mechanics achieved over the past few years has allowed the use of powerful methods of flow calculation in developments of new blading with greatly enhanced efficiencies. Thanks to the latest manufacturing techniques, the newly developed blading systems can be produced at low cost. Next to progress in flow mechanics, also the broadbased use of advanced finite-element calculations resulted in a more thorough grasp of the many problems associated with structural mechanics assessment of steam turbine components. The theoretical methods have been supplemented by comprehensive efforts in fracture mechanics and experimental materials studies, thus helping to create a reliable knowledge base which will help to avoid the dreaded stress corrosion cracking ...
1996-01-01
Multiphase reacting flow modeling of singlet oxygen generators for chemical oxygen iodine lasers.
Energy Technology Data Exchange (ETDEWEB)
Singlet oxygen generators are multiphase flow chemical reactors used to generate energetic oxygen to be used as a fuel for chemical oxygen iodine lasers. In this paper, a theoretical model of the generator is presented along with its solutions over ranges of parameter space and oxygen maximizing optimizations. The singlet oxygen generator (SOG) is a low-pressure, multiphase flow chemical reactor that is used to produce molecular oxygen in an electronically excited state, i.e. singlet delta oxygen. The primary product of the reactor, the energetic oxygen, is used in a stage immediately succeeding the SOG to dissociate and energize iodine. The gas mixture including the iodine is accelerated to a supersonic speed and lased. Thus the SOG is the fuel generator for the chemical oxygen iodine laser (COIL). The COIL has important application for both military purposes--it was developed by the US Air Force in the 1970s--and, as the infrared beam is ...
2008-08-01
Flow Vaporization of CO{sub 2} in Microchannel Tubes
Energy Technology Data Exchange (ETDEWEB)
Carbon dioxide is receiving renewed interest as an efficient and environmentally safe refrigerant in a number of applications, including mobile air conditioning and heat pump systems, and hot water heat pumps. Compact heat exchangers for CO{sub 2} systems are designed with small-diameter tubing. The purpose of this study is therefore to provide a better basis for understanding and predicting heat transfer and pressure drop during flow vaporization of CO{sub 2} in microchannels. The ''unusual'' properties of carbon dioxide give heat transfer and two-phase flow characteristics that are very different from those of conventional refrigerants. Examples of these differences are the much higher pressure, the resulting high vapour density, a very low surface tension, and a low liquid viscosity. High pressure and low surface tension has a major effect on nucleate boiling characteristics, and earlier test data have ...
2002-07-01
Energy Technology Data Exchange (ETDEWEB)
A whole sequence of the parameters of the combined heat and power system (KWK) is described which enables a comparison between the electricity and heat demand of a consumer and the energy availability through a combined heat and power system. Proceeding from this, a thermodynamic model of a steam and gas process with combined heat and power is introduced which is based on an exergetic balancing of the subsystems of the process. In this way, the varying thermodynamic quality of the energy flows occuring in the process will be taken into consideration so that the results of the model correspond in any case with the second law of thermodynamics. (orig.) [Deutsch] Es wird ein vollstaendiger Satz von Kenngroessen der Kraft-Waerme-Kopplung (KWK) beschrieben, mit dessen Hilfe der Strom- und Waermebedarf eines Verbrauchers mit der Energiebereitstellung durch eine KWK-Anlage verglichen werden kann. Darauf ...
1996-03-01
The use of supplementary firing in an externally-fired combined cycle power plant
Energy Technology Data Exchange (ETDEWEB)
The most developed systems for the generation of electricity from coal are the Integrated coal Gasification Combined Cycle (IGCC) and the Pressurized Fluidized Bed Combustion (PFBC) system. They both represent state-of-the-art technology and provide electric power at 41-46% LHV efficiency. However, the high level of complexity leads to lower reliability and higher costs. A simpler system, based on a coal-fired steam boiler integrated with a gas turbine, has been proposed. In such a plant, known as the externally fired combined cycle (EFCC), compressed air is heated indirectly in a heat exchanger located in the coal furnace. The hot air is then expanded in a turbine, and the exhaust is passed on to the coal furnace as preheated combustion air. Steam produced in the boiler generates additional power in a steam turbine. The exclusion of coal combustion products from the gas turbine avoids hot gas clean-up and turbine blade corrosion by coal ash. ...
1997-12-31
N F Q k q V N h l b hs x j p bN t gX Y I r bN X U Y Fff c o t dA A p A DA2 AC7LAR A Ak VAwt A jA A A A t A bNA A A dZA A A A A A X A A M A LA A E A A wA V A A A A oA V A A oA M A...
2011-02-17
uJ Ccna =+!F Vl,) (On# P*9p .FGww z,r` dcb= >uD/ rN3W $ gp0w# rW8- A$c= b8aU Pkfs pmRh }>Tua }zz~ EwHc D;t' =kF9 hk6d /_sU }+>IK j'$ 0=:b "OR? ,2pz{V# U}}6 ...
The electrical measurement of AC losses in a three-phase tri-axial superconducting cable
International Nuclear Information System (INIS)
In a three-phase tri-axial cable, the magnetic interaction between the phases makes the loss measurement by an electromagnetic method very complex. We developed the theoretical background showing that three-phase AC loss measurements by the electromagnetic method are, in principle, possible. We then implemented this theory in practical measurements on a 3 m long, tri-axial cable fabricated from RABiTS (rolling-assisted biaxially textured substrate) coated conductor. Initially, the proposed measurement technique was implemented in the simpler cases when the three cable phases are 180"0 out of phase, i.e. (0"0, 180"0, 360"0) or (0"0, 360"0, 180"0) rather than (0"0, 120"0, 240"0) as in a traditional three-phase system. For these cases, the currents in the phases are either in phase (360"0 phase difference) or anti-phase (180"0 phase difference). These are essentially single-phase measurements with only one transport current used as the supply for all three phases. ...
2010-09-01
Organic molecules are a significant and highly varied component of atmospheric aerosols. Measurement of aerosol composition and improvements in our understanding of the complex chemistry involved in their formation and aging are being aided by innovations in soft ionization aerosol MS. (To listen to a podcast about this feature, please go to the Analytical Chemistry multimedia page at pubs.acs.org/page/ancham/audio/index.html.). PMID:21275431
2011-01-24
UK PubMed Central (United Kingdom)
BackgroundTroponin is the preferred biomarker for risk stratification in non-ST-elevation ACS. The incremental prognostic utility of the initial magnitude of troponin...Full Text Available
2010-06-01
Development of a retrofit coal combustor for industrial applications
Energy Technology Data Exchange (ETDEWEB)
In this first quarterly technical report for DOE Contract No. DE-AC22-87PC79654, a description of the background, technology, and application is provided. The design and fabrication of advanced combustion chambers were completed during this period. Initial testing on both the bare metal and refractory lined advanced chambers were initiated. The units were tested initially with gas but primarily with coal. A Pittsburgh No. 8 pulverized coal was used for these test activities. Both advanced chambers pulsed well.
1987-01-01
Critical current measurements of high Tc superconductors in a scanning low temperature cryostat
Energy Technology Data Exchange (ETDEWEB)
Maintaining uniformity of properties over long distances is one of the fabrication problems encountered with the new high {Tc} superconductors. Uniform properties are crucial in long tapes or wires with high critical current since local nonuniformities can limit the current carrying capacity of the whole piece. Transport critical currents in high {Tc} superconductors are conventionally measured with the contact 4-point probe DC current-voltage technique. This technique requires contact with the sample and and spatially averages over the region between the two voltage contacts. Two techniques have been used to infer the critical state model. The first uses the net magnetization of a suitably shaped sample in an external magnetic field. The second combines a DC magnetic field with AC induced currents to infer spatial flux profiles. The AC magnetization technique offers an advantage in that it is noncontacting; however, it also averages the ...
1991-01-01
UK PubMed Central (United Kingdom)
Background:Acute Coronary Syndrome (ACS) can occur in patients with prior coronary artery bypass grafting (CABG). In the Gulf Registry of acute coronary events (Gulf RACE), we identified...Full Text Available
Environmental Research Database
DescriptionCEH - Quest CCMAP see http://quest.bris.ac.uk/research/themes/CCMAP.html CCMAP (Climate-carbon modelling, assimilation and prediction) Leader: Dr. Eleanor Blyth (CEH, Wallingford) Overview and Goals CCMAP is one of QUEST's Theme 1 projects and is about to be commissioned to the Centre for Ecology and Hydrology at Wallingford. The Principal Investigator will be Dr. Eleanor Blyth, with subcontracts to the Universities of Bristol (Dr. Wolfgang Knorr, Earth Sciences and QUEST; Andy Ridgw [continued...
Accommodation : Accommodation, campus and Brighton : ... : University of Sussex
... Further information For more detailed information on available accommodation, refer to our housing guide At home with us, visit Residential Services, or contact : T +44 (0)1273 678220 E housing@sussex.ac.uk Davidrsquo;s perspective lsquo;When my wife and I decided to study at Sussex, we applied for University accommodation. We were delighted with the lovely self-contained flat on Clifton Road in Brighton that we got via the Housing Office. ...
A comparison of methods for calculating audible noise of high voltage transmission lines
Energy Technology Data Exchange (ETDEWEB)
During the last several years, audible noise produced by high voltage transmission lines in corona has emerged as an important design consideration. In this same time frame a number of different methods for calculating audible noise levels have been proposed. The methods currently available, for both ac and dc lines, are described in this paper and are compared through application to practical line geometries for which data from long-term measurements are available.
1982-10-01
Study on thermal-hydraulics during a PWR reflood phase
International Nuclear Information System (INIS)
In-core thermal-hydraulics during a PWR reflood phase following a large-break LOCA are quite unique in comparison with two-phase flow which has been studied widely in previous researches, because the geometry of the flow path is complicated (bundle geometry) and water is at extremely low superficial velocity and almost under stagnant condition. Hence, some phenomena realized during a PWR reflood phase are not understood enough and appropriate analytical models have not been developed, although they are important in a viewpoint of reactor safety evaluation. Therefore, author investigated some phenomena specified as important issues for quantitative prediction, i.e. (1) void fraction in a bundle during a PWR reflood phase, (2) effect of radial core power profile on reflood behavior, (3) effect of combined emergency core coolant injection on reflood behavior, and (4) the core separation into two thermal-hydraulically different ...
1983-12-13
Shell Temperatures for a Single-Heater Diffuser
Energy Technology Data Exchange (ETDEWEB)
A new diffuser/permeator design has been proposed for a new Savannah River Site tritium project. The use of a single heater well in the center of the shell had raised concerns that the Pd/Ag coils may be shielding radiative heat transfer to the walls thus reducing Pd/Ag tube temperatures near the shell below the recommended minimum operating temperature. The diffuser was fitted with thermocouples to measure shell temperatures during testing. Tests were run with the shell evacuated, helium feed flows of 0, 1000, and 2000 sccm; bleed pressures ranging from 0 to 203 kPa, and heater temperatures of 650, 675, and 700 degrees C. Hydrogen permeation tests were run with two hydrogen/helium mixtures and feed rates to simulate 1st and 2nd stage diffuser operations. Approximately 20 hours were required to bring the diffuser from ambient temperature to steady-state conditions. For tests with a heater temperature of 675 degrees C and no hydrogen flow, ...
2004-11-01
STOMP, Subsurface Transport Over Multiple Phases, theory guide
Energy Technology Data Exchange (ETDEWEB)
This guide describes the simulator`s governing equations, constitutive functions and numerical solution algorithms of the STOMP (Subsurface Transport Over Multiple Phases) simulator, a scientific tool for analyzing multiple phase subsurface flow and transport. The STOMP simulator`s fundamental purpose is to produce numerical predictions of thermal and hydrologic flow and transport phenomena in variably saturated subsurface environments, which are contaminated with volatile or nonvolatile organic compounds. Auxiliary applications include numerical predictions of solute transport processes including radioactive chain decay processes. In writing these guides for the STOMP simulator, the authors have assumed that the reader comprehends concepts and theories associated with multiple-phase hydrology, heat transfer, thermodynamics, radioactive chain decay, and nonhysteretic relative permeability, saturation-capillary pressure constitutive functions. ...
1996-10-01
Natural circulation reactor design safety analysis
This thesis study covers both global performance and local phenomena analyses focusing on natural circulation reactor design safety. Four important topics are included: the global SBWR design safety assessment, important local phenomena investigation, steady and transient natural circulation process study, and two-phase instability analysis. The conceptual design of the SBWR-200 is introduced in this thesis and the global performance of a natural circulation reactor is then assessed using PUMA integral test data and RELAP5 simulations. A safety assessment methodology is developed to evaluate the PUMA integral test data extrapolation and code scalability. The RELAP5 code simulation capability in low-pressure low-flow conditions is also validated. The study shows that the code is capable of predicting the global accident scenario in natural circulation reactors with reasonable accuracy, while failing to reproduce some safety related local phenomena. The natural ...
2001-01-01
Application of neutron radiography systems in JRR-3M to nuclear engineering
Energy Technology Data Exchange (ETDEWEB)
Initial major applications of neutron radiography (NR) to nuclear engineering were nondestructive inspections of nuclear fuel, control rods, reactor materials and some other components. Increase in the available neutron flux over 10{sup 8} n/cm{sup 2}s at the JRR-3M thermal neutron radiography facility (TNRF) in 1991 has expanded the application field to the dynamic but clear imaging of moving objects and fluid phenomena. The JRR-3M TNRF is facilitated with three major imaging systems, being characterized by spatial and/or temporal resolutions: 1. Static neutron radiography (SNR), 2. real-time neutron radiography (RNR) with an imaging rate of 30 frames/s and 3. High-frame-rate neutron radiography (HFRNR). SNR has been used for three-dimensional visualization of air-water two-phase flows in a simulated rod bundle. Three-dimensional computed tomography clearly illustrated average void fraction distributions around tie spacers. RNR has been used for visualization and ...
1999-07-01
Theoretical and Experimental Investigation of Flamespreading ...
... CHANNELS, TWO PHASE FLOW, WAVES, IGNITERS, GAS FLOW, HOWITZERS, CARTRIDGE CASES, COMBUSTIBLE CARTRIDGE CASES. ...
1986-02-01
Special Course on Three-Dimensional Supersonic ...
... Dynamics Panel Executive AGARD 7 rue ... 4 AXIAL FLOW IN CORNERS AT SUPERSONIC ... AND HYPERSONIC FLOWS INCLUDING SEPARATION ...
1990-01-01
LAMINAR SEPARATION IN SUPERSONIC AND ...
... Agard Report 272,1960 ... and reattached subsonic turbulent flows obtained downstream ... of flow separations due to deflected control surfaces. ...
1966-09-30
Diaphragm Rupture Effects on an Expanding Flow in a Tube.
... The fundamental problem of diaphragm rupture was studied experimentally to determine the effects on an expanding flow in an evacuated tube. ...
1972-08-01
Application of neutron radiography to visualization of multiphase flows
Energy Technology Data Exchange (ETDEWEB)
Visualizations by real-time neutron radiography are demonstrated of various flow patterns of nitrogen gas-water two-phase flow in a stainless-steel tube, water inverted annular flow in a stainless-steel tube, flashing flow in an aluminium nozzle and fluidized bed in aluminium tube and vessels. Photographs every 1/60 s are presented by an image processing method to show the dynamic behaviours of the various flow patterns. It is shown that this visualization method can be applied efficiently to multiphase flow researches and will be applicable to multiphase flows in industrial machines. (author).
1990-04-01
Application of neutron radiography to visualization of multiphase flows
International Nuclear Information System (INIS)
Visualizations by real-time neutron radiography are demonstrated of various flow patterns of nitrogen gas-water two-phase flow in a stainless-steel tube, water inverted annular flow in a stainless-steel tube, flashing flow in an aluminium nozzle and fluidized bed in aluminium tube and vessels. Photographs every 1/60 s are presented by an image processing method to show the dynamic behaviours of the various flow patterns. It is shown that this visualization method can be applied efficiently to multiphase flow researches and will be applicable to multiphase flows in industrial machines. (author).
1990-01-01
Energy Technology Data Exchange (ETDEWEB)
The performance of the Magma Power Company's reinjection well No. 46-7 at East Mesa has been examined. Water was cooled to 100/sup 0/F(+-) to simulate total heat extraction and then tested using membrane filter flow procedures. The cooled water contains particles which are in the high colloid size range, and formation impairment by these particles is unlikely. There is evidence that acid soluble corrosion products and calcium compounds constitute about two thirds of the particulates, and that the acid insoluble residue contains precipitated silica, insoluble corrosion products, and possibly formation fines carried in the produced water. Under stabilized conditions, the suspended solids content of the water is less than 2 parts per million. However, during the frequent production well start ups, a higher concentration of suspended solids is carried in the produced water and into the injection well, conceivably augmenting fill in the ...
1980-02-01
Heat transfer augmentation by gas-particle two-phase flow
International Nuclear Information System (INIS)
The helium-cooled HTGR (High Temperature Gas-cooled Reactor) will take an important position in the global energy strategy. It is expected to supply not only electricity but also high quality thermal energy for various industries and local utilities without exhausting any green house effect gas or acid rain gas. The key R and D issue of the HTGR is economical competitiveness, particularly against light water reactors. Due to the poor heat transfer of the single phase helium, the HTGR's volumetric power density is restricted to tenth of corresponding PWR's value so that increasing the power density by improving heat transfer is strongly desired. The standstill can be broken through by adopting gas-solid suspension medium. Its heat transfer performance is quite excellent. Its heat capacity can be increased drastically without excessive pressurization. Although the thermal radiation is a dominant heat transfer mode in high temperature region, the ...
1995-06-01
Energy Technology Data Exchange (ETDEWEB)
The theoretical analysis of a partially-ionized hydrogen gas flow (gas temperatures of approximately 10,000 to 20,000 K) through a particular class of magnetohydrodynamic (MHD) generators and the preliminary design of these MHD generators as open cycle, electric power supplies are performed. Analysis of the gas flow through these ultra-high temperature MHD generators requires a coupled gas dynamics/radiative heat transfer solution. Gas dynamics are modeled by a set of quasi-one-dimensional, nonlinear differential equations which account for friction, convective and radiative heat transfer and the interaction between the ionized gas and applied magnetic field. Radiative heat transfer is modeled using non-gray, absorbing-emitting two- and three-dimensional P-1 approximations which permit an arbitrary variation of the spectral absorption coefficient with frequency. Gas dynamics and radiative heat transfer are coupled through ...
1990-01-01
Interfacial Area and Interfacial Transfer in Two-Phase Flow Systems (Volume IV. Chapters 15-19)
Energy Technology Data Exchange (ETDEWEB)
Experiments were performed on horizontal air-water bubbly two-phase flow, axial flow, stratified wavy flow, and annular flow. Theoretical studies were also undertaken on interfacial parameters for a horizontal two-phase flow.
2003-03-15
Energy Technology Data Exchange (ETDEWEB)
A Real-Time Neutron Radiography (RTNR) system is used to determine two-phase flow parameters for a horizontal co-current two-phase flow channel with a CANDU-type 37 rod bundle. Image processing techniques are applied to visualize the two-phase flow, and to determine flow regime, cross-sectional averaged void fraction, time averaged void fraction, and void distribution. The experimentally determined flow regime map disagrees with existing flow regime models developed for the CANDU-type rod bundles. A new flow regime is observed and designated Large Amplitude Stratified Wavy flow. The results show that the LASW flow regime may be due to a combination of undeveloped flow phenomena, boundary conditions, and circumferential cross flow occurring in the bundle. The ...
1997-12-31
Energy Technology Data Exchange (ETDEWEB)
A real-time neutron radiography (RTNR) system is used to determine two-phase flow parameters for a horizontal co-current two-phase flow channel with a cylindrical 37 rod bundle. Image processing techniques are applied to visualize the two-phase flow, and to determine flow regime, cross-sectional averaged void fraction, time averaged void fraction, and void distribution. The experimentally determined flow regime map disagrees with existing flow regime models developed for the cylindrical rod bundles. A new flow regime is observed and designated large amplitude stratified wavy (LASW) flow. The results show that the LASW flow regime may be due to a combination of undeveloped flow phenomena, boundary conditions, and circumferential cross flow occuring in the ...
2000-08-01
International Nuclear Information System (INIS)
A Real-Time Neutron Radiography (RTNR) system is used to determine two-phase flow parameters for a horizontal co-current two-phase flow channel with a CANDU-type 37 rod bundle. Image processing techniques are applied to visualize the two-phase flow, and to determine flow regime, cross-sectional averaged void fraction, time averaged void fraction, and void distribution. The experimentally determined flow regime map disagrees with existing flow regime models developed for the CANDU-type rod bundles. A new flow regime is observed and designated Large Amplitude Stratified Wavy flow. The results show that the LASW flow regime may be due to a combination of undeveloped flow phenomena, boundary conditions, and circumferential cross flow occurring in the bundle. The ...
1997-10-04
Flow regime transfer conditions for two-phase flow in a fracture
Energy Technology Data Exchange (ETDEWEB)
Between 25 and 30 percent of total known petroleum reserves are contained within oil-laden fractured reservoirs where the dominant flow path is through the fractures. Economic oil recoveries from fractured reservoirs depend on a better understanding of the flow in fractures and networks of fractures. However, the flow of heavy oil and water, and particularly the flow regime map for two-phase immiscible flow has received less attention in contrast with gas-liquid flow in fractures. This paper discussed the use of flow pattern observations in a Hele-Shaw cell to generate two-phase flow regime maps. The paper investigated the effect of fracture gap and fluid viscosities on flow regimes. A correlation based on different flow and fracture properties was developed to define ...
2010-07-01
Energy Technology Data Exchange (ETDEWEB)
Applications, techniques, instrumentation, and interpretation of flow visualization are discussed. Methods of using flow visualization for the examination of combustion in furnaces, heat transfer with heat exchangers, and in fluid engines are explored, along with flow visualization in food processing, steel-casting, and process engineering. Further attention is given to pipe and channel flow, flow separation in laminar flow and around oscillating airfoils, wakes and vortices, supersonic flow and shock waves, and stratified flow and oceanography. The visualization of boundary layers is considered for various conditions, and applications for multiphase flow, rheology, and medical problems are detailed. Oil film, dry-surface coating, chemical, fluorescent, and minituft methods are presented, as well as ...
1982-01-01
Energy Technology Data Exchange (ETDEWEB)
In the present study, a new measurement technique which uses a ultrasonic transmission signals in order to determine the vertical two phase flow pattern even under high pressure condition. The ultrasonic measurement system developed in the present study not only provides the measurement functions required for the determination of vertical two phase flow pattern but also makes the real time determination possible. The developed ultrasonic measurement system accurately determined the various vertical two phase flow patterns such as bubbly, slug, churn, annular flow etc. In addition to the determination of flow patterns, qualitative informations for each flow pattern can be obtained, which include void fraction in bubbly flow, length of slug bubble and liquid tail characteristics in slug flow, and stable or transient ...
2002-03-01
Energy Technology Data Exchange (ETDEWEB)
A two-phase flow regime map is developed experimentally and theoretically for a vertical hexagonal flow channel with and without a 36-finned rod hexagonal bundle. This type of flow channel is of interest to MAPLE-type nuclear research reactors. The flow regime maps are determined by visual observations and observation of waveforms shown by a capacitance-type void fraction meter. The experimental results show that the inclusion of the finned hexagonal bundle shifts the flow regime transition boundaries toward higher water flow rates. Existing flow regime maps based on pipe flow require slight modifications when applied to the hexagonal flow channel with and without a MAPLE-type finned hexagonal bundle. The proposed theoretical model agrees well with experimental results.
1997-05-01
International Nuclear Information System (INIS)
A two-phase flow regime map is developed experimentally and theoretically for a vertical hexagonal flow channel with and without a 36-finned rod hexagonal bundle. This type of flow channel is of interest to MAPLE-type nuclear research reactors. The flow regime maps are determined by visual observations and observation of waveforms shown by a capacitance-type void fraction meter. The experimental results show that the inclusion of the finned hexagonal bundle shifts the flow regime transition boundaries toward higher water flow rates. Existing flow regime maps based on pipe flow require slight modifications when applied to the hexagonal flow channel with and without a MAPLE-type finned hexagonal bundle. The proposed theoretical model agrees well with experimental results.
1997-01-01
Energy Technology Data Exchange (ETDEWEB)
Different calculated models are presented for turbulent break-off flows and their classification, reflecting the sequence of historical development. The study was done based on equations of viscous liquid of the Navier-Stokes type with development of special phenomenological models of turbulence which take into consideration real properties of the break-off flows based on simpler models of flow presented in the work. In order to calculate two-dimensional turbulent flows, a method of viscous-nonviscous interaction is used. It employs numerical solutions for nonviscous flow and integrated methods of calculating the dissipative region. This method can be extended for calculating the transonic break-off flows, and also break-off in an incompressible fluid when there is cavitation.
1982-01-01
GREENHOUSE GAS EMISSIONS CONTROL BY OXYGEN FIRING IN CIRCULATING FLUIDIZED BED BOILERS
Energy Technology Data Exchange (ETDEWEB)
Given that fossil fuel fired power plants are among the largest and most concentrated producers of CO{sub 2} emissions, recovery and sequestration of CO{sub 2} from the flue gas of such plants has been identified as one of the primary means for reducing anthropogenic CO{sub 2} emissions. In this study, ALSTOM Power Inc. (ALSTOM) has investigated several coal fired power plant configurations designed to capture CO{sub 2} from effluent gas streams for use or sequestration. Burning fossil fuels in mixtures of oxygen and recirculated flue gas (made principally of CO{sub 2}) essentially eliminates the presence of atmospheric nitrogen in the flue gas. The resulting flue gas is comprised primarily of CO{sub 2}. Oxygen firing in utility scale Pulverized Coal (PC) fired boilers has been shown to be a more economical method for CO{sub 2} capture than amine scrubbing (Bozzuto, et al., 2001). Additionally, oxygen firing in Circulating ...
2003-05-15
Low-friction snow plow evaluation
Energy Technology Data Exchange (ETDEWEB)
Canadian railway traffic is delayed until lines are plowed of snow following heavy snowfalls. A modification that would permit higher plowing speeds and fewer delays could realize significant benefits in addition to direct fuel and labor savings. The objective of this project was to carry out a cost benefit analysis on a low-friction coating applied to a mainline railway snow plow. The assessment was carried out using old Canadian National Railway snow plows for test purposes. An analytical model was developed to estimate the importance of friction reduction to fuel consumption and power requirements. The sensitivity analysis revealed a bump or discontinuity in the power vs speed profile, corresponding to the minimum plow speed at which the snow will cease to flow over the plow. Reducing the coefficient of friction reduces this minimum plowing speed. This could mean the difference between success and failure in plowing some ...
1988-09-01
HEXTRAN-SMABRE calculation of the 6th AER Benchmark, main steam line break in a WWER-440 NPP
International Nuclear Information System (INIS)
The sixth AER benchmark is the second AER benchmark for couplings of the thermal hydraulic codes and three dimensional neutron kinetic core models. It concerns a double end break of one main steam line in a WWER-440 plant. The core is at the end of its first cycle in full power conditions. In VTT HEXTRAN2.9 is used for the core kinetics and dynamics and SMABRE4.8 as a thermal hydraulic model for the primary and secondary loop. The plant model for SMABRE consists mainly of two input models, Loviisa model and a standard WWER-440/213 plant model. The primary loop includes six separate loops, the pressure vessel is divided into six parallel channels in SMABRE and the whole core calculation is performed in the core with HEXTRAN. The horizontal steam generators are modelled with heat transfer tubes in five levels and vertically with two parts, riser and downcomer. With this kind of detailed modelling of steam generators there occurs strong flashing after break opening. ...
2003-11-01
Application of a power system stabilizer in the nuclear power plant Borssele
Energy Technology Data Exchange (ETDEWEB)
After that power fluctuations had occurred at Borssele nuclear power station it was decided to install a power system stabilizer. This stabilizer shall reduce the unwanted power fluctuations. The preliminary research and the results of measurements carried out during commissioning are described. (J.C.R.)
1985-03-01
Heat transfer augmentation of a circular pipe flow using nano-particle layers
International Nuclear Information System (INIS)
For the advanced fusion reactor FFHR2 (Force Free Helical Reactor) that has been proposed by NIFS, molten salt Flibe (LiF:BeF2=64:36) breeder blanket system is selected because of Flibe's features such as chemical stability, low-pressure operation and low electric conductivity. The Flibe is however high Prandtl number fluid since it has high viscosity and low thermal conductivity. Therefore its heat transfer performance is low compared with liquid Li or Pb-Li. In addition to heat removal of 1MW/m2 on the first wall, electrolysis of molten salt due to MHD effect will take place under high flow rate condition. This indicates that heat transfer enhancement under low flow rate is essential for the Flibe blanket system. In our laboratory, heat transfer characteristics of molten salt HTS (KNO3:NaNO2:NaNO3=53:40:7), have been evaluated, which is used as a simulant fluid of Flibe from the points of view of Be's toxicity and similar Prandtl number. In ...
2007-10-05
Visualization of liquid metal two-phase flow by a real time neutron radiography system
Energy Technology Data Exchange (ETDEWEB)
In order to understand the detail transient two-phase flow structure, more advanced two-phase flow instrumentation is required. One advanced technique for flow visualization is real-time neutron radiography. Reconstruction method of visualized radiographic image of liquid metal two-phase flow generated by the real-time neutron radiography system is proposed in this paper. Image processing techniques for noise reduction and image enhancement are discussed in detail. (author).
1995-11-01
Visualization of liquid metal two-phase flow by a real time neutron radiography system
International Nuclear Information System (INIS)
In order to understand the detail transient two-phase flow structure, more advanced two-phase flow instrumentation is required. One advanced technique for flow visualization is real-time neutron radiography. Reconstruction method of visualized radiographic image of liquid metal two-phase flow generated by the real-time neutron radiography system is proposed in this paper. Image processing techniques for noise reduction and image enhancement are discussed in detail. (author).
1995-01-01
Mixed convection flows in a channel with a vortex generator
This paper presents a numerical investigation of laminar flows and heat transfer in a horizontal rectangular channel whose top and bottom plates have been punched out in the form of a delta wing. The flow structure with respect to the generation, transport, and stability of vortices in laminar horizontal channel flows with combined forced and free convection are reported. To include free convection, Boussinesq approximation of the buoyancy is used and the flow medium is treated as incompressible.
1989-01-01
Gas-liquid two-phase flow patterns in parallel channels for fuel cells
Energy Technology Data Exchange (ETDEWEB)
Two-phase flow in horizontal parallel channels has been experimentally investigated under fuel cell related operating conditions. Pronounced hysteresis is observed in the pressure drop versus flow characteristic curve when starting from either flooded or dry conditions. When gas is introduced into channels initially filled with water (flooded initial condition), both gas and liquid tend to flow predominantly in one channel at low gas or liquid flow velocities. As the gas flow velocity increases, even distribution of gas and liquid flow in both channels is observed, accompanied with a sudden decrease in the pressure drop. On the other hand, even gas and liquid flow distribution between both channels is found at comparatively lower gas flow velocities when starting with dry-gas flow conditions with ...
2008-09-01
Energy Technology Data Exchange (ETDEWEB)
Full text of publication follows: Different to the very simple class of homogeneous non-equilibrium models (HEM) an one dimensional thermal-hydraulic theoretical drift-flux based and thus non-homogeneous coolant channel model and, as a result, an in itself complete thermal-hydraulic coolant channel module CCM have been established allowing to simulate in a very general way the steady state and transient behaviour of the most important parameters of a single- or two-phase fluid flowing within any type of heated or non-heated coolant channel (with an eventually varying cross flow area). To avoid mathematical discontinuities at the transition from single- to two-phase flow the coolant channel will, in its general form, be split into different regions, i.e. be looked as a basic channel (BC) which can consist of a number of different flow regimes and can, accordingly, be subdivided into a number of ...
2005-07-01
NFAT involvement in adipocyte physiological processes was examined by treatment with CsA and/or GSK3{beta} inhibitors (Li{sup +} or TZDZ-8), which prevent or increase NFAT nuclear translocation, respectively. CsA treatment reduced basal and TNF{alpha}-induced rates of lipolysis by 50%. Adipocytes preincubated with Li{sup +} or TZDZ-8 prior to CsA and/or TNF{alpha}, exhibited enhanced basal rates of lipolysis and complete inhibition of CsA-mediated decreased rates of lipolysis. CsA treatment dramatically reduced the mRNA levels of adipocyte-specific genes (aP2, HSL, PPAR{gamma}, ACS and Adn), compared with control or TNF{alpha}-treatment, whereas Li{sup +} pretreatment blocked the inhibitory effects of CsA, and mRNA levels of aP2, HSL, PPAR{gamma}, and ACS were found at or above control levels. NFAT nuclear localization, assessed by EMSA, confirmed that CsA or Li{sup +} treatments inhibited or increased NFAT nuclear translocation, respectively. ...
2007-09-21
International Nuclear Information System (INIS)
The level structure and configurations of "2"1"6At have been studied by observing the alpha decay of "2"2"0Fr, which is in secular equilibrium with "2"2"4Ac. Six of the 16 observed states are tentatively assigned to the configuration #pi#(h_9_/_2)"3#upsilon#(g_9_/_2)"5, and four to the mixed configuration #pi#(h_9_/_2)"3#upsilon#(g_9_/_2)"4(i_1_1_/_2)+#pi#(h_9_/_2)"2(f _7_/_2)#upsilon#(g_9_/_2)"5. These two configurations in "2"1"6At are compared with the corresponding configurations in "2"1"2Bi and "2"1"0Bi. The shape transitions are traced from the quadrupole-octupole deformed "2"2"4Ac through "2"2"0Fr and "2"1"6At, to "2"1"2Bi, described by the spherical shell model, using the alpha decay sequence beginning with "2"2"8Pa. copyright 1996 The American Physical Society.
Impedance analysis of hydrogen adsorption on palladium in 0. 1 M NaOH solution
Energy Technology Data Exchange (ETDEWEB)
The behaviour of hydrogen adsorption on palladium has been investigated by a.c. impedance measurements in 0.1 M NaOH solution of pH 13 at 298 K. The electrode impedance has been measured by superimposing an a.c. voltage of 5 mV amplitude ranging between 10{sup -1} and 10{sup 4} Hz on a d.c. potential range from -0.76 to 0.44 V (standard hydrogen electrode (SHE)). The equivalent circuit representing the hydrogen adsorption reaction is proposed from the analysis of the frequency dependence of electrode admittance. The capacitance, arising from the adsorbed hydrogen, has been determined as a function of applied potential by complex non-linear least-squares curve fitting method based on the proposed equivalent circuit. As the cathodic applied potential increased from -0.36 to -0.76 V (SHE), the adsorption capacitance considerably increased owing to the enhanced coverage of hydrogen adsorbed on the palladium surface. In the applied potential range ...
1991-10-21
Hybridization and Modification of the Ni/C{sub 60} Composites
Hybridization and thermal evolution of the Ni+C{sub 60} composites, deposited on Si(001) at room temperature, were studied using Scanning Electron Microscopy, {mu}-Raman spectroscopy and Rutherford Backscattering. As-deposited, the hybrid films exhibited a granular nano-structure with Ni nano-particles encapsulated in C{sub 60} polymerized rinds. The Ni and C (C{sub 60}) distributions in a top layer were found homogeneous with a stable Ni/C (C{sub 60}) ratio; in the larger depth the distributions were inhomogeneous and their ratio dramatically varied. At elevated temperatures, all structural parameters were changed. In the subsurface layer Ni- and C (C{sub 60})-rich zones were formed (due to the induced phase separation), C{sub 60}-molecules decayed and their fragments were transformed into amorphous carbon (a-C). The free volume distribution of the stressed hybrid matter was analyzed by the Hg marker that (in a form of vapors) in-diffused in to the samples. The ...
2009-03-10
Energy Technology Data Exchange (ETDEWEB)
The electrode kinetics for oxygen reduction on conducting metal oxides, including lithiated NiO (formed in situ) and Sb-doped SnO/sub 2/, have been investigated. Kinetic measurements were carried out by using ac impedance and coulostatic relaxation methods. The ac behavior on the oxide electrodes was analyzed on the basis of a modified Randles-Ershler type equivalent circuit which takes into account the effect of non-faradaic components due to the semiconducting oxide films. The kinetic parameters (the charge transfer resistance and Warburg coefficient) and the interfacial parameters (the double layer capacity, film capacity and film resistance) were obtained by a least squares curve fitting method under P/sub O2//P/sub CO2/=0.9/0.1 atmosphere. The exchange current density was found to be 10 to 20 mA cm/sup -2/ at the oxide electrodes, assuming n=2. The coulostatic relaxation experiments supported the magnitude of the i/sub o/ values.
1986-01-01
Energy Technology Data Exchange (ETDEWEB)
In this work, a new class of thiadiazole derivatives, namely 3,5-bis(2-thienyl)-1,3,4-thiadiazole (2-TTH) and 3,5-bis(3-thienyl)-1,3,4-thiadiazole (3-TTH), have been studied as possible corrosion inhibitors for mild steel in molar hydrochloric acid (1M HCl). Polarisation curves and AC impedance methods have been used. These studies have shown that the thiadiazole derivatives were very good inhibitors for mild steel in 1M HCl. Comparison of results showed that 3-TTH was the best inhibitor. The potential of zero charge (PZC) of mild steel was studied by ac impedance method, and the mechanism of adsorption has been predicted. X-ray photoelectron spectroscopy surface analysis with thiadiazole derivatives shows that it chemisorbed at the mild steel/HCl interface. The adsorption of these inhibitors followed Langmuir's adsorption isotherm. The electronic properties of 2-TTH and 3-TTH, obtained using the AM1 semi-empirical quantum chemical ...
2004-07-01
Electrochemical properties of passive films on 440C stainless steel. Ph. D. Thesis
Energy Technology Data Exchange (ETDEWEB)
Type 440C stainless steel is a high-C, high-Cr martensitic steel used in applications requiring high hardness and wear resistance in combination with moderate corrosion resistance. Typical applications include precision aerospace bearings and critical components in computer disk drives. The properties of passive films formed on 440C steel were investigated using advanced electrochemical techniques with a view to establishing a method to measure film stability directly in the passivation baths. Electrochemical measurements were sensitive to the passive film properties and were able to quantify the effect of cooling rate on passive film stability. The techniques used included linear polarization, AC impedance, small amplitude cyclic voltammetry, and coulostatic transient measurements. These provided results that exhibited excellent agreement with the AC impedance technique providing the most information about the interfacial reactions. It was ...
1990-10-01
Energy Technology Data Exchange (ETDEWEB)
Two types of switched electrode electronics beam position monitors are in use at Jefferson Lab. Together they provide accurate beam position to the control system for beam intensities between 50 nA and 2 mA. One version, called the linac style, has a switching frequency of 125 kHz. The other, called the transport type, has a switching frequency of 7 kHz. The basic system provides information to the control system at a 1 Hz update rate. The systems are regularly used to measure the AC component of beam position and energy as well as suppress this motion as part of a fast feedback system. Position data produced by the system are also acquired on an event by event basis as part of the nuclear physics program in two of the experimental halls. This paper will focus on the AC characteristics of the system. These characteristics are affected by analog filter frequencies and a time delay between the measurement of the positive electrode signal and the ...
2000-05-01
The objective of the program is to develop a domestic cooktop with low-NOx emissions and high efficiency. During the first two phases of the program, three design concepts were developed, and two versions of developmental prototypes using the IR-Jet approach were fabricated and tested. The third phase was initiated to address the design issues of burner turndown and modulation and to conduct the field test of a prototype with one IR-Jet and three conventional burners. Two prototypes containing one IR-Jet and three conventional burners and utilizing blower speed control for air/gas modulation were fabricated. One unit employed a brushless dc motor and the other a 2-pole ac motor. The ac motor prototype was field tested. Field testing showed the need for a mechanical air/gas valve for modulation and for a 1500 Btu/hr simmer setting. A 4-inch-diameter stepped-tile configuration provided input rates from 1500 to 8000 Btu/hr. A manufacturer, Copreci ...
1987-06-01
Energy Technology Data Exchange (ETDEWEB)
The US Department of Energy`s Pittsburgh Energy Technology Center (PETC) is actively pursuing the development and testing of coal-fired combustion systems for residential, commercial, and industrial market sectors. In response, MTCI initiated the development of a new combustor technology based on the principle of pulse combustion under the sponsorship of PETC (Contract No. AC22-83PC60419). The initial pulse combustor development program was conducted in three phases (MTCI, Development of a Pulsed Coal Combustor Fired with CWM, Phase III Final Report, DOE Contract No. AC22-83PC60419, November 1986). Phase I included a review of the prior art in the area of pulse combustion and the development of pulse combustor design concepts. It led to the conclusion that pulse combustors offer technical and base-of-operation advantages over conventional burners and also indicated favorable economics for replacement of oil- and gas-fired equipment.
1990-12-31
Development and testing of commercial-scale, coal-fired combustion systems, Phase 3
Energy Technology Data Exchange (ETDEWEB)
The US Department of Energy's Pittsburgh Energy Technology Center (PETC) is actively pursuing the development and testing of coal-fired combustion systems for residential, commercial, and industrial market sectors. In response, MTCI initiated the development of a new combustor technology based on the principle of pulse combustion under the sponsorship of PETC (Contract No. AC22-83PC60419). The initial pulse combustor development program was conducted in three phases (MTCI, Development of a Pulsed Coal Combustor Fired with CWM, Phase III Final Report, DOE Contract No. AC22-83PC60419, November 1986). Phase I included a review of the prior art in the area of pulse combustion and the development of pulse combustor design concepts. It led to the conclusion that pulse combustors offer technical and base-of-operation advantages over conventional burners and also indicated favorable economics for replacement of oil- and gas-fired equipment.
1990-01-01
CuBr blue light emitting electroluminescent thin film devices
British Library Electronic Table of Contents (United Kingdom)
Abstract Visible blue cathodoluminescence (CL), photoluminescence (PL), x-ray excited optical luminescence (XEOL) and electroluminescence (EL) via Zf free excitonic emission have been obtained from CuBr thin films deposited on glass, Cr coated glass, GaAs and Si substrates. In addition to the Zf emission several peaks corresponding to Cu+ emissions via 3d94s - d10 transitions were observed on the AC EL spectrum at 2.10, 2.7, 3.03, 3.07 and 3.80 eV. X-ray diffraction (XRD) measurements confirmed that the vacuum evaporated CuBr thin films grow preferentially with a (111) orientation irrespective of the substrate. While the AC voltage source was found to have no detrimental effects on CuBr thin films, cathodic deposition of Cu metal via electrolytic decomposition was observed under steady sta...
2011-01-01
AC loss measurements of model and full size 50mm SSC collider dipole magnets at Fermilab
Energy Technology Data Exchange (ETDEWEB)
Tests have recently been performed at Fermilab in order to measure the energy losses due to eddy currents and iron and superconductor magnetization. These measurements were performed on six 1.5m long model magnets and eight 15m long full scale collider dipole magnets. AC losses were measured as a function of ramp rate using sawtooth ramps from 500, to 5000 Amps for both types of magnets, while bipolar studies were additionally performed on some of the short magnets. The measured magnet voltage and current for a complete cycle are digitally integrated to yield the energy loss per cycle. Measurement reproducibility is typically 5%, with good agreement between long magnet measurements and extrapolations from short magnet measurement results. Magnetization loss measurements among similar magnet types agree to within experimental error, while eddy current losses correlate strongly with the observed dependence of quench current on ramp rate.
1992-09-01
Underwater plasma arc cutting in Three Mile Island's reactor
Energy Technology Data Exchange (ETDEWEB)
On March 28, 1979, the Pennsylvania Three Mile Island nuclear power plant Unit 2 (TMI-2) suffered a partial fuel-melt accident. During this accident, over 20,000 lb of molten fuel flowed through holes melted through the baffle plates and through the lower-core support assembly (LCSA). The molten fuel subsequently resolidified in the bottom of the reactor vessel. The lower-core support assembly of the TMI-2 reactor was not structurally damaged during the accident. In order to permit defueling of that region of the core, the LCSA was cut to permit access. A five-axis teleoperator was developed to deliver plasma arc cutting, rotary grinding and abrasive waterjet cutting of end effectors to the LCSA. Complex geometry sectioning was completed in a mock-up facility at chemistry and pressure conditions simulating those of the vessel, prior to actual in-vessel operations. In-vessel activities began in early May 1988 and were completed on April 11, ...
1989-07-01
Transport characteristics of dehydrogenated ammonia borane and sodium borohydride spent fuels
Energy Technology Data Exchange (ETDEWEB)
Ammonia borane (AB) and sodium borohydride (SBH) are candidate materials for on-board hydrogen storage that can be dehydrogenated upon demand. The rheological properties of the dehydrogenated by-products are important to quantify their removal and transportability from the hydrogen storage system. This paper presents visco-elastic property (elastic stiffness and viscous damping) measurements of the spent fuels obtained from AB hydrolysis, hydrothermolysis and thermolysis; and SBH hydrolysis. Smaller stiffness and larger mobility (or smaller viscous damping) indicate better transportability of the spent fuel. In addition, flow property (dynamic angle of repose and avalanching time) measurements for the hydrolysis spent fuels of AB and SBH are also presented. Comparing with the SBH hydrolysis spent fuel, the AB hydrolysis spent fuel had a lower stiffness and larger mobility, as well as lower angles of dynamic repose and avalanche power peaks, ...
2010-03-15
Transient performance of FFTF [Fast Flux Test Facility] reference fuel
International Nuclear Information System (INIS)
Fourteen irradiated Fast Flux Test Facility (FFTF) fuel pins were subjected to representative overpower transients in six flowing sodium loop experiments conducted in the TREAT reactor. The transient tests were extended to substantial overpower levels well beyond protected levels, with some tests intentionally run to failure to identify failure thresholds and characteristics. Test variables included transient ramp rate (5, 50, and 100 cents/s) and burnup (2 to 58 MWd/kg). Performance limits and failure characteristics were identified, and cladding strain and fuel melting data were obtained for development and verification of transient analysis codes. The test results demonstrated that FFTF Reference fuel pins are capable of surviving overpower levels well beyond the FFTF secondary Plant Protection System (PPS) trip limit of 1.25 times normal rated power. Based on analytical evaluations to interpolate and extrapolate test results to the full ...
1986-09-07
International Nuclear Information System (INIS)
PWR plants have made efforts to maintain the long-term integrity of the steam generators (SG) by reducing the amount of corrosion products entering the secondary side of the SG. Iron entered the SG can cause several problems: degraded heat conductivity of the SG tubes in locations where iron is deposited, water level oscillations in the SG due to tube support plate hole blockage, and initiation and propagation of inter-granular attacks (IGA) and stress corrosion cracking (SCC). One of the most effective measures, high all-volatile treatment (AVT) chemistry has been applied to actual plants to reduce the flow-accelerated corrosion (FAC) coming from the carbon steel piping. The secondary water chemistry at Genkai NPS 1 and 2 changed, from the Low AVT chemistry to the High AVT chemistry, in November 2006. In this paper, we will describe the results of experiments in applying the use of High pH water in the secondary water system at Genkai NPS. (author)
2009-02-01
Status of he-cooled divertor development (PPCS subtask TW4-TRP-001-D2)
International Nuclear Information System (INIS)
Within the framework of the EU power plant conceptual study (PPCS), helium-cooled modular divertor concepts have been investigated in detail at the Forschungszentrum Karlsruhe during the past few years. The first conceptual design proposed was based on convective cooling with the use of flow promoters in the form of pin and/or slot arrays (HEMP/HEMS) to increase the cooling surface and, hence, enhance the heat transfer capacity. While continuing the design optimisation, an advanced multiple-jet design (HEMJ) was introduced, which is based on direct jet-to-wall impinging cooling and offers advantages in terms of simple construction and manufacturing. Main emphasis of the 2004 work program (TW4-TRP-001) lay on experiments for the concepts HEMJ and HEMS, which were mainly performed at the Efremov Institute in St. Petersburg, Russia. For experiment preparation, detailed test programs were worked out and accompanying CFD analyses were accomplished. ...
International Nuclear Information System (INIS)
A calculation program (URA 6.F4) was elaborated on FORTRAN IV language, that through finite differences solves the unidimensional scalar Helmholtz equation, assuming only one energy group, in spherical cylindrical or plane geometry. The purpose is the determination of the flow distribution in a reactor of spherical cylindrical or plane geometry and the critical dimensions. Feeding as entrance datas to the program the geometry, diffusion coefficients and macroscopic transversals cross sections of absorption and fission for each region. The differential diffusion equation is converted with its boundary conditions, to one system of homogeneous algebraic linear equations using the box integration technique. The investigation on criticality is converted then in a succession of eigenvalue problems for the critical eigenvalue. In general, only is necessary to solve the first eigenvalue and its corresponding eigenvector, employing the power method. The ...
1993-11-18
Energy Technology Data Exchange (ETDEWEB)
Using a coplanar, end-mounted antenna as a baseline, various configuration trades were performed to select a preferred solid state concept. The increase in efficiency that could be realized by use of multi bandgap solar cells, either with klystron or solid state antenna was evaluated. Satellite configurations were developed to exploit the sandwich antenna concept wherein solar cells are located on one side of the antenna panel and solid state dc/RF converters on the other side. These concepts entailed various primary and secondary reflector arrangements for directing solar energy to the solar cell side of the antenna with higher concentration ratios than used on the coplanar configurations. Operations analysis included development of a satellite construction scenario, a concept for the SCB, a top-level satellite construction operation, construction operation, construction timelines and crew sizes, mass flows to orbit, and a satellite maintenance scenario. The list ...
1981-03-01
SCDAP/RELAP5/MOD 3.1 code manual: Interface theory. Volume 1
Energy Technology Data Exchange (ETDEWEB)
The SCDAP/RELAP5 code has been developed for best estimate transient simulation of light water reactor coolant systems during a severe accident. The code models the coupled behavior of the reactor coolant system, core, fission product released during a severe accident transient as well as large and small break loss of coolant accidents, operational transients such as anticipated transient without SCRAM, loss of off-site power, loss of feedwater, and loss of flow. A generic modeling approach is used that permits as much of a particular system to be modeled as necessary. Control system and secondary system components are included to permit modeling of plant controls, turbines, condensers, and secondary feedwater conditioning systems. This volume describes the organization and manner of the interface between severe accident models which are resident in the SCDAP portion of the code and hydrodynamic models which are resident in the RELAP5 portion ...
1995-06-01
Research on Dynamic Neutron Radiography in HANARO
Energy Technology Data Exchange (ETDEWEB)
Neutron radiography is a non-destructive test method to examine a material by using the dependency of neutron attenuation on the nuclear characteristics of the atoms composing the object material. There are two categories of neutron radiography; static neutron radiography and dynamic neutron radiography. The static neutron radiography is a technique to observe a standing object by using a camera or a film cassette. The dynamic neutron radiography(DNR) is a technique to observe a moving object usually by using a camera. Depending on the camera frame rate, the dynamic neutron radiography is categorized into the real time neutron radiography(RTNR) and the high speed neutron radiography(HSNR). The frame rate for RTNR is 30 frames/s and that for HSNR is usually more that 500 frames/sec. Thus, RTNR is good for observing time-averaged phenomena and HSNR is good for observing instantaneous phenomena. DNR is a powerful tool for fluid visualization as well as the multi-phase ...
2005-07-01
Research on Dynamic Neutron Radiography in HANARO
International Nuclear Information System (INIS)
Neutron radiography is a non-destructive test method to examine a material by using the dependency of neutron attenuation on the nuclear characteristics of the atoms composing the object material. There are two categories of neutron radiography; static neutron radiography and dynamic neutron radiography. The static neutron radiography is a technique to observe a standing object by using a camera or a film cassette. The dynamic neutron radiography(DNR) is a technique to observe a moving object usually by using a camera. Depending on the camera frame rate, the dynamic neutron radiography is categorized into the real time neutron radiography(RTNR) and the high speed neutron radiography(HSNR). The frame rate for RTNR is 30 frames/s and that for HSNR is usually more that 500 frames/sec. Thus, RTNR is good for observing time-averaged phenomena and HSNR is good for observing instantaneous phenomena. DNR is a powerful tool for fluid visualization as well as the multi-phase ...
2005-10-27
Reliability assessment of embedded digital system using multi-state function
Energy Technology Data Exchange (ETDEWEB)
This work describes a combinatorial model for estimating the reliability of the embedded digital system by means of multi-state function. This model includes a coverage model for fault-handling techniques implemented in digital systems. The fault-handling techniques make it difficult for many types of components in digital system to be treated as binary state, good or bad. The multi-state function provides a complete analysis of multi-state systems as which the digital systems can be regarded. Through adaptation of software operational profile flow to multi-state function, the HW/SW interaction is also considered for estimation of the reliability of digital system. Using this model, we evaluate the reliability of one board controller in a digital system, Interposing Logic System (ILS), which is installed in YGN nuclear power units 3 and 4. Since the proposed model is a generalized combinatorial model, the simplification of this model becomes ...
2006-03-15
Recrystallization in AZ31 magnesium alloy during hot deformation
Energy Technology Data Exchange (ETDEWEB)
In this study, isothermal torsion tests were carried out on magnesium AZ31B alloy under constant strain rate conditions, in the range of 250 to 400 C at 0.01, 0.1, and 1.0 s{sup -1}. Alloy flow stress dependence on strain rate and temperature can be described by a power law with activation energy of 130 kJ/mol. Microstructural examination of hot deformed samples shows very fine recrystallized grains decorating grain boundaries of larger gains in the form of a necklace. These fine grains are produced by dynamic recrystallization at the grain boundaries of original grains. Microstructure evolution, based on samples quenched at different strain levels, indicates that increasing deformation strain has little effect on recrystallized grain size but widens the recrystallized region, with full recrystallization achieved at a certain high strain level. Recrystallized grain size increases with increasing deformation temperature and strain rate. The ...
2005-07-01
Recent historical changes on the Belgian Meuse
International Nuclear Information System (INIS)
When a nuclear power station was installed on the Meuse in central Belgium, the impact of thermal, radioactive, and chemical waste on the water of the Neuse and on its biocenoses was studied. Three successive periods of development of the channel bed and the flood plain in Belgium have occurred, and their hydrological, physicochemical, and ecological consequences have been examined. Since the last century, the ecosystem of the Meuse has undergone, due to the increasing activity of man, modifications of increasing importance: marked reduction of the water flow, a drastic increase in the suspended material being transported, a degree of eutrophication of the water, and the disturbance of the original floral and faunal communities. The causes of this evolution of the Meuse can be itemized as different types of human interference in descending order of importance: (1) occupation of the catchment area; (2) encroachment on the flood plain; (3) ...
Energy Technology Data Exchange (ETDEWEB)
One aspect of the research program SFB 570 'Distortion engineering' is the in situ X-Ray diffraction analysis of phases and residual stresses during complete heat treatment cycles. These investigations result in experimental evidence available for the extensive computations. The optimisation of the instrumentation will be reported. A surface decarburisation of samples made from the ball bearing steel 100Cr6 could be avoided for a temperature range from 800 to 900 C and a holding time of one hour by a combination of evacuate the furnace and using a certain nitrogen flow as protective gas. At lower temperatures small amounts of ferrite caused by an increased diffusion rate of carbon lead again to a surface decarburisation up to a depth of 2 {mu}m. It was proved that with an evacuation of the X-Ray beam path at constant power of the X-Ray source the intensity of diffraction lines could be increased by more than a factor of 4. The ...
2007-07-01
RELAP5/MOD3 code manual. Volume 4, Models and correlations
International Nuclear Information System (INIS)
The RELAP5 code has been developed for best-estimate transient simulation of light water reactor coolant systems during postulated accidents. The code models the coupled behavior of the reactor coolant system and the core for loss-of-coolant accidents and operational transients such as anticipated transient without scram, loss of offsite power, loss of feedwater, and loss of flow. A generic modeling approach is used that permits simulating a variety of thermal hydraulic systems. Control system and secondary system components are included to permit modeling of plant controls, turbines, condensers, and secondary feedwater systems. RELAP5/MOD3 code documentation is divided into seven volumes: Volume I presents modeling theory and associated numerical schemes; Volume II details instructions for code application and input data preparation; Volume III presents the results of developmental assessment cases that demonstrate and verify the models used ...
1995-08-05
Program plan for development of underground hydroelectric pumped storage technology
The Underground Hydroelectric Pumped Storage (UHPS) Program Plan describes in detail the planned activities and expected accomplishments in the conduct of UHPS technology development and validation envisioned in the 1976 to 1990 time frame. This document describes the program objectives, implementation strategy, and management methodology. The concept of underground hydroelectric pumped storage is fully directed to application in the electric utility industry. This technology involves using electrical energy generated by base-load plants during off-peak load periods to drive a high-head pump/turbine which pumps water from a lower reservoir to a substantially elevated (upper) reservoir corresponding to a head of 1000 m or so. The upper reservoir is at ground level and the lower reservoir is below ground. Then, during peak-load periods, water in the upper reservoir is allowed to flow to the lower reservoir which, in turn, drives a hydraulic turbine for ...
1976-03-01
Power generation using coir-pith and wood derived producer gas in diesel engines
Energy Technology Data Exchange (ETDEWEB)
Partial combustion of biomass in the gasifier generates producer gas that can be used for heating purposes and as supplementary or sole fuel in internal combustion engines. In this study, the potential of coir-pith and wood chips as the feedstock for gasifier is analyzed. The performance of the gasifier-engine system is analyzed by running the engine for various producer gas-air flow ratios and at different load conditions. The system is experimentally optimized with respect to maximum diesel savings and lower emissions in the dual fuel mode operation while using coir-pith and wood chips separately. The performance and emission characteristics of the dual fuel engine are compared with that of diesel engine at different load conditions. Specific energy consumption in the dual fuel mode of operation is found to be in the higher side at all load conditions. The brake thermal efficiency of the engine while using wood chips in the dual mode operation is higher than that ...
2006-10-15
Powdering characteristics of thin film evaporator, 1. Drying and powdering of solution
Energy Technology Data Exchange (ETDEWEB)
Vertical thin film evaporators have been used to concentrate and dry solutions because their rotating swing blades prevent scale from being deposited on the heated surfaces. Powdering capacity of the vertical thin film evaporator was examined experimentally for drying applications of radioactive liquid waste generated from nuclear power plants. As a result, it was found that the powdering capacity increased with the blade rotation, changing significantly in the low ratational region and scarcely in the high rotational region. The powdering capacity in the high rotational region was restricted by the lack of heat flux which was theoretically evaluated for the concentrating process. As the critical factor in the low rotational region was not clear, a visual test apparatus was made to observe flow patterns in the evaporator, and a powdering model was obtained. This model showed that powdering process was obstructed when the liquid film lost its ...
1983-01-01
Powdering characteristics of thin film evaporator, 1
International Nuclear Information System (INIS)
Vertical thin film evaporators have been used to concentrate and dry solutions because their rotating swing blades prevent scale from being deposited on the heated surfaces. Powdering capacity of the vertical thin film evaporator was examined experimentally for drying applications of radioactive liquid waste generated from nuclear power plants. As a result, it was found that the powdering capacity increased with the blade rotation, changing significantly in the low ratational region and scarcely in the high rotational region. The powdering capacity in the high rotational region was restricted by the lack of heat flux which was theoretically evaluated for the concentrating process. As the critical factor in the low rotational region was not clear, a visual test apparatus was made to observe flow patterns in the evaporator, and a powdering model was obtained. This model showed that powdering process was obstructed when the liquid film lost its ...
1983-01-01
International Nuclear Information System (INIS)
A comparative assessment of five different heat transfer configurations for operation in compact heat exchangers is presented. The configurations under consideration are four standaed heat exchanger surfaces - two plain fin, an offset strip and a louvered fin geometry - and one surface with so called vortex generators for heat transfer augmentation. In the case of the standard surfaces, the basic performance characteristics in the form of heat transfer and friction data versus the Reynolds number have been taken from published experimental results. In the case of the vortex generator surface, the performance characteristics have been derived from a numerical prediction of the flow and temperature field in a closely spaced parallel plate channel with vortex generators in the form of delta wings mounted on the channel walls. In comparison to the plain fin surfaces with a rectangular cross section, the vortex generator surface shows best performance characteristics ...
1993-01-01
Opto-acoustic recanilization delivery system
Energy Technology Data Exchange (ETDEWEB)
Fiber delivered laser pulses emulsify thrombus by mechanical stresses that include a combination of pressure, tension and shear stress. Laser radiation is delivered to the locality of a thrombus and the radiation is absorbed by blood, blood dot, or other present materials. The combination of a leading pressure wave and subsequent vapor bubble cause efficient, emulsification of thrombus. Operating the laser in a low average power mode alleviates potential thermal complications. The laser is operated in a high repetition rate mode to take advantage of ultrasound frequency effects of thrombus dissolution as well as to decrease the total procedure time. Specific parameter ranges for operation are described. The device includes optical fibers surrounding a lumen intended for flow of a cooling agent. The fibers may be arranged concentrically around the lumen to deliver radiation and heat over as large an area as possible. An alternative design ...
2002-01-01
Operating experience with solidification of radioactive waste by a thin-film evaporator
Energy Technology Data Exchange (ETDEWEB)
In the nuclear power stations of GDR the rough radioactive waste includes borat-containing evaporator bottoms and spent ion exchanger resins. For its final disposal in deep geological formations (rock salt mines) this waste has to be solidified. The experience of one year lasting operation of a steam heated thin-film evaporator (heating surface 2 m{sup 3}) for evaporator bottoms to be solidified with a solid content of 200-250 g/l are reported on. In short time such amount of water is abstracted from the rough waste that due to the borate content a hot high-viscous product passes from evaporator to waste drum and there solidifies like glass to monolith. The product quality depends on the adjustment of the flow-equilibrium in the evaporator. Boric acid is used as matrix for the radioactive residues. The residual water content of the solidified waste product was about 15-20%, the volume reduction was V{sub f}=5...6. In order to be sure to get a ...
1990-01-01
Operating experience with solidification of radioactive waste by a thin-film evaporator
International Nuclear Information System (INIS)
In the nuclear power stations of GDR the rough radioactive waste includes borat-containing evaporator bottoms and spent ion exchanger resins. For its final disposal in deep geological formations (rock salt mines) this waste has to be solidified. The experience of one year lasting operation of a steam heated thin-film evaporator (heating surface 2 m"3) for evaporator bottoms to be solidified with a solid content of 200-250 g/l are reported on. In short time such amount of water is abstracted from the rough waste that due to the borate content a hot high-viscous product passes from evaporator to waste drum and there solidifies like glass to monolith. The product quality depends on the adjustment of the flow-equilibrium in the evaporator. Boric acid is used as matrix for the radioactive residues. The residual water content of the solidified waste product was about 15-20%, the volume reduction was V_f=5...6. In order to be sure to get a solidified ...
1990-06-01
Energy Technology Data Exchange (ETDEWEB)
Two computational problems were worked on for this study. The first chapter examines the option of coal combustion using oxygen feed with carbon dioxide recycle to control the adiabatic flame temperature. Computer simulations using an existing state-of-the-art 3-dimensional computer code for turbulent reacting flows with reacting particles were employed to study the effects of increased carbon dioxide mole fraction on the char burnout, radiant heat transfer, metal partitioning, and NOx formation. The second chapter compares assumptions for the CO/CO{sub 2} ratio at the surface of mineral inclusions made in previous studies to predictions obtained from a pseudo-steady state kinetic model (SKIPPY) for a single porous particle. The detailed kinetic simulations from SKIPPY for varying particle sizes and bulk gas compositions were used to develop algebraic expressions for the CO/CO{sub 2} ratio that can be incorporated into metal vaporization sub-models run as a post ...
2002-02-28
Energy Technology Data Exchange (ETDEWEB)
In this paper the problem of developing optimal bidding strategies for the participants of oligopolistic energy markets is studied. Special attention is given to the impacts of suppliers' emission of pollutants on their bidding strategies. The proposed methodology employs supply function equilibrium (SFE) model to represent the strategic behavior of each supplier and locational marginal pricing mechanism for the market clearing. The optimal bidding strategies are developed mathematically using a bilevel optimization problem where the upper-level subproblem maximizes individual supplier payoff and the lower-level subproblem solves the Independent System Operator's market clearing problem. In order to solve market clearing mechanism the multiobjective optimal power flow is used with supplier emission of pollutants, as an extra objective, subject to the supplier physical constraints. This paper uses normal boundary intersection ...
2010-06-15
Logistics modeling of future solid waste storage, treatment, and disposal
Energy Technology Data Exchange (ETDEWEB)
Logistics modeling is a powerful analytical technique for effective planning of waste storage, treatment, and disposal activities. Logistics modeling facilitates analyses of alternate scenarios for future waste flows, facility schedules, and processing or handling capacities. These analyses provide an increased understanding of the specific needs for waste storage, treatment, and disposal while adequate time remains to plan accordingly. They also help to determine the sensitivity of these needs to various system parameters. This paper discusses a logistics modeling system developed by the Pacific Northwest Laboratory (PNL) to aid in solid waste planning for a large industrial complex managing many different types and classifications of waste. The basic needs for such a system are outlined, and the approach adopted in developing the system is described. A key component of this approach is the development of a conceptual model that provides a ...
1993-11-01
Large temperature differential thermal storage system. Its design and evaluation
Energy Technology Data Exchange (ETDEWEB)
A large temperature differential (10K) thermal storage system in a small (4400 m{sup 2}) 8-storey office building is discussed and the monitoring results are analyzed in comparison with computer simulations. Requirements were a comfortable indoor environment and system cost effectiveness. Out of four potential system concepts, the Large Temperature Differential System was chosen. It comprises a flat-type thermal stratification heat storage tank in the under floor pit of the building as the heat source for a variable flow heat pump chiller. The heat sink is a set of serially connected air handling and fan coil units. The tank`s capacity is sized for one day operation and is made as large as possible to shift the electricity demand to night time. To avoid a large size and high cost, the water temperature differential was enlarged. The role of Tokyo Electric Power Company (TEPCO) was to develop the chiller and its control system. It is concluded ...
1996-07-01
Laboratory ageing of transformer oils
Energy Technology Data Exchange (ETDEWEB)
The insulating oil used in a transformer is a critical component, as its service life is typically 20 years with possibly little or no maintenance. Partial discharges (PD), thermal overloads and static discharges continually subject the oil to chemical deterioration during its operating life. To ensure equipment reliability during service, it is important that the initial quality of the new insulating oil should meet the required acceptance specifications and preferably be pre-tested before use. Accelerated aging tests have been devised to determine the life expectancy of oil in service by using forced air or oxygen flow into the oil, the presence of a copper catalyst, and at elevated temperatures. The more important standards relating to transformer application are discussed and highlights of the more important aspects of the oxidation chemistry of hydrocarbons are included. The ultimate aim of the project is the formulation of better standard testing methods and ...
1996-04-01
Heat-driven liquid metal cooling device for the thermal management of a computer chip
International Nuclear Information System (INIS)
The tremendous heat generated in a computer chip or very large scale integrated circuit raises many challenging issues to be solved. Recently, liquid metal with a low melting point was established as the most conductive coolant for efficiently cooling the computer chip. Here, by making full use of the double merits of the liquid metal, i.e. superior heat transfer performance and electromagnetically drivable ability, we demonstrate for the first time the liquid-cooling concept for the thermal management of a computer chip using waste heat to power the thermoelectric generator (TEG) and thus the flow of the liquid metal. Such a device consumes no external net energy, which warrants it a self-supporting and completely silent liquid-cooling module. Experiments on devices driven by one or two stage TEGs indicate that a dramatic temperature drop on the simulating chip has been realized without the aid of any fans. The higher the heat load, the larger ...
2007-08-07
Fuel assembly and reactor core
International Nuclear Information System (INIS)
In a fuel assembly having moderator rods, an axial average value of a ratio between the total of the lateral cross sectional area of a portion to be filled with moderators and the total of the lateral cross sectional area of fuel pellets is determined as greater than 0.4, a lateral cross sectional area of a portion to be filled with moderators per one moderator rod is determined as from 14 to 50cm"2 and the ratio between the total of the lateral cross sectional area of moderators and a total of the lateral cross sectional area of fuel pellets in a horizontal cross section is determined as from 2.7 to 3.4. Since the axial average value for lateral cross sectional area of a portion to be filled with moderators/lateral cross sectional area of fuel pellets is determined as #>=# 0.4, the lateral cross sectional area of moderators of moderator rods is increased, the lateral cross sectional area of a gap water region is decreased to reduce the value of local power ...
1992-12-03
Experiments with the HORUS-II test facility
Energy Technology Data Exchange (ETDEWEB)
Within the scope of the German reactor safety research the thermohydraulic computer code ATHLET which was developed for accident analyses of western nuclear power plants is more and more used for the accident analysis of VVER-plants particularly for VVER-440,V-213. The experiments with the HORUS-facilities and the analyses with the ATHLET-code have been realized at the Technical University Zittau/Goerlitz since 1991. The aim of the investigations was to improve and verify the condensation model particularly the correlations for the calculation of the heat transfer coefficients in the ATHLET-code for pure steam and steam-noncondensing gas mixtures in horizontal tubes. About 130 condensation experiments have been performed at the HORUS-II facility. The experiments have been carried out with pure steam as well as with noncondensing gas injections into the steam mass flow. The experimental simulations are characterized as accident simulation tests ...
1997-12-31
Enthalpy changes upon partial evaporation of aqueous solutions containing ammonia and carbon dioxide
Energy Technology Data Exchange (ETDEWEB)
The thermodynamic properties of aqueous solutions containing ammonia and sour gases such as carbon dioxide, sulfur dioxide, or hydrogen sulfide must be known in many applications. A typical example is the cleaning of raw gases in power stations. The enthalpy changes upon partial evaporation of aqueous solutions containing ammonia and of aqueous solutions containing ammonia and carbon dioxide were measured at temperatures from 313 to 393 K with a thin film evaporator flow calorimeter. The molalities of ammonia and carbon dioxide entering the calorimeter ranged up to 12 and 6 mol/kg, respectively. The physicochemical model originally developed by Edwards et al. (1978) and further modified and extended by Kurz et al. (1995) to describe phase equilibria in aqueous systems containing ammonia and carbon dioxide is used to derive a predictive enthalpy model for this complex, chemical reactive system. Comparisons between the new experimental results ...
1998-08-01
Effect of primary air content on formation of nitrogen oxides during combustion of Ehkibastuz coal
Energy Technology Data Exchange (ETDEWEB)
Investigations are discussed carried out in a pilot plant at the Kaz. Power Engineering Scientific Research Institute into the effect of the amount of primary air in coal-dust flame on the final concentration of nitrogen oxides in flue gases. The tests were carried out in a 7500 mm high, 1600 mm dia vertical cylindrical combustion chamber having type P-57 burner, and air dispersed fuel plus additional air supplies located at the top. Amounts of coal dust fed by a drum feeder along the air pipe varied from 100-600 kg/h. The required air was supplied by 5000 m/sup 3//h Type TK-700/5 blowers at 0.04 MPa. Ehkibastuz coal samples contained: 1.3% moisture; 48.1% ash; 38.02% carbon; 2.56% hydrogen; 0.73% sulfur; 0.60% nitrogen; heat of combustion was 14.3 MJ/kg. Results obtained indicate that variations in the amount of primary air in swirl flow burners affect formation of fuel nitrogen; there is an optimum volume at which minimum quantities of ...
1986-01-01
Development and validation of steam generator models for thermal performance monitoring
International Nuclear Information System (INIS)
The thermal performance monitoring and optimization system TEMPO is developed at the OECD Halden Reactor Project. The system supports staff of nuclear power plants in identification and correction of problems, which cause small decreases in plant efficiency but which may lead to significant economical losses. The system-wide physical model consists of mathematical description of individual components, such as the reactor, the pumps, the heat exchangers, or the turbines, etc. TEMPO code has recently been extended with new steam generator (SG) models. The present paper summarizes the thermal-hydraulic modelling aspects of the vertical and the horizontal SG. The heat balance equations and their solution are shown with the appropriate initial and boundary conditions. The method of the calculation of the pressure losses are also introduced. The vertical SG model is based on a U-tube structure and treated as a 1D flow channel. The horizontal approach ...
2003-04-20
Designing a healthy house - an overview
Energy Technology Data Exchange (ETDEWEB)
There are certain factors to take into account when determining the suitability of a healthy house site. Power lines, agricultural spraying, vehicle exhaust, and industrial pollution are all potential sources of indoor air contamination. It is recommended that a environmental assessment be done to determine whether there are specific sources of contamination. Good drainage is required. The surrounding landscaping should be open and sunlit, and with low maintenance requirements. Decks and fences made from pressure-treated or chemical treated lumber should be avoided. One of the early decisions in the design process is the choice of the structural system. The key with all foundation types is to control moisture, whether from rain, from the ground, or the condensation of moisture from the air with cooling. The construction frame is sealed away from the occupants by the air/vapor barrier, so only in extreme cases is it essential to use alternatives to softwood lumber ...
1999-11-01
Conversion of the Midland nuclear station
Energy Technology Data Exchange (ETDEWEB)
The authors report how the Midland cogeneration venture (MCV) is repowering the incomplete Midland nuclear plant to operate as a gas-fired combined cycle cogeneration facility. They discuss how their company is responsible for performing engineering, procurement, licensing, construction, start-up, training, and operational assistance for this facility. As shown, twelve gas turbine generator sets supply heat to twelve heat recovery steam generators (HRSGs), which are headered together on the steam side to provide energy to either of two existing steam turbine generators. This combination of equipment enables approximately 1,380 MWe of electrical generation capability, while supplying an average steam flow of 629,000 lbs/hr to an adjacent Dow Chemical Company pant. The MCV facility will also provide 60 MW of electric power to Dow. The authors report how the Midland ccogeneration venture (MCV) is repowering the incomplete Midland nuclear plant to ...
1988-01-01
Energy Technology Data Exchange (ETDEWEB)
Swift heavy ion-solid interaction leads in volume to track creation and on the surface to the ejection of particles into the vacuum. To learn more about initial mechanisms of track formation, we are focused on the sputtering of uranium dioxide by fast heavy ions. This present study is exclusively devoted to the influence of the electronic stopping power on the emission of neutral particles and especially on their angular distribution. These measurements are completed by those of the ions emitted from UO{sub 2} targets bombarded with swift heavy ions. The whole experimental results give access to: i) the nature of the sputtered particles; ii) the charge state of the emitted particles; iii) the direction of ejection of the sputtered particles ; iv) the sputtering yields deduced from the angular distributions. These results are compared to the prediction of the sputtering models proposed in the literature and it seems that the supersonic gas flow ...
2001-03-01
Condensation driven water hammer studies for feed water distribution pipe
International Nuclear Information System (INIS)
Special T-shaped feedwater distribution pipes were installed in steam generators at the Loviisa (Finland) and Rovno (Russia) nuclear power plants. The new shape was tested in an extensive testing programme. Since the tubes frequently suffer from corrosion damage, large-scale water hammer experiments were performed on a model facility in 1996. The main objectives of the water hammer experiments were to find out the prevailing parameters leading to water hammers, as well as the sensitivity of hammering to boundary conditions. A water hammer may occur when the mass flow rate into the steam generator exceeds 6 kg/s and the temperature difference between steam generator and feedwater exceeds 100 degC. Visual experiments and stress analyses of the pipe were also carried out. The weakest part, the T-joint, may hold against such water hammers only for a limited time of the order of few minutes. (M.D.).
1997-05-26
Comprehensive simulations of superhumps
(Abridged) We use 3D SPH calculations with higher resolution, as well as with more realistic viscosity and sound-speed prescriptions than previous work to examine the eccentric instability which underlies the superhump phenomenon in semi-detached binaries. We illustrate the importance of the two-armed spiral mode in the generation of superhumps. Differential motions in the fluid disc cause converging flows which lead to strong spiral shocks once each superhump cycle. The dissipation associated with these shocks powers the superhump. We compare 2D and 3D results, and conclude that 3D simulations are necessary to faithfully simulate the disc dynamics. We ran our simulations for unprecedented durations, so that an eccentric equilibrium is established except at high mass ratios where the growth rate of the instability is very low. Our improved simulations give a closer match to the observed relationship between superhump period excess and binary ...
2007-01-01
Clear liquor scrubbing with anhydrite production. Fourth quarter 1996 technical progress report
Energy Technology Data Exchange (ETDEWEB)
This project is part of PETC`s Advanced Power Systems Program, whose mission is to accelerate the commercialization of affordable, high- efficiency, low emission, coal-fueled electric generating technologies. A process concept - Clear Liquor Scrubbing with Anhydrite Production - was proposed and accepted by PETC as a Phase I project in its Mega-PRDA program. the project integrated three process operations - chloride control upstream of the flue gas desulfurization (FGD) system, a clear liquor process for enhanced SO{sub 2} removal performance, and production of anhydrite (anhydrous calcium sulfate) rather than calcium sulfite or gypsum (calcium sulfate dihydrate). The first step in the project was to perform batch and flow-through experiments in the laboratory to confirm theoretical calculations and preliminary laboratory results concerning anhydrite formation, these laboratory experiments were designed to prove that anhydrite can be produced ...
1997-02-03
CFD Application to the Regulatory Assessment of FAC-Caused CANDU Feeder Pipe Wall Thinning Issue
Energy Technology Data Exchange (ETDEWEB)
From the results of the In-Service Inspection (ISI) measuring the wall thickness of outlet (hot-leg side) feeder pipes performed at two Canadian nuclear power plants, Point Lepreau and Gentilly-2 in 1995 and 1996, respectively, the wall thinning degradation of feeder pipes at the bend part was found to be much more severe than expected. It has been well known that such wall thinning of feeder pipes is caused by the flow accelerated corrosion (FAC) which is one of the mechanical-chemical degradation mechanisms affecting the integrity of piping systems. For the Wolsung unit 1, the wall thickness measurements have been performed during every overhaul period since 1996. The wall thinning rates at the bends of outlet feeder pipes were assessed to exceed the design value. However, for the Wolsung units 2, 3 and 4, the wall thinning rates of all the outlet feeder pipes were assessed not to exceed it. The reason is because the content of Cr in the ...
2007-07-01
CFD Application to the Regulatory Assessment of FAC-Caused CANDU Feeder Pipe Wall Thinning Issue
International Nuclear Information System (INIS)
From the results of the In-Service Inspection (ISI) measuring the wall thickness of outlet (hot-leg side) feeder pipes performed at two Canadian nuclear power plants, Point Lepreau and Gentilly-2 in 1995 and 1996, respectively, the wall thinning degradation of feeder pipes at the bend part was found to be much more severe than expected. It has been well known that such wall thinning of feeder pipes is caused by the flow accelerated corrosion (FAC) which is one of the mechanical-chemical degradation mechanisms affecting the integrity of piping systems. For the Wolsung unit 1, the wall thickness measurements have been performed during every overhaul period since 1996. The wall thinning rates at the bends of outlet feeder pipes were assessed to exceed the design value. However, for the Wolsung units 2, 3 and 4, the wall thinning rates of all the outlet feeder pipes were assessed not to exceed it. The reason is because the content of Cr in the ...
2007-05-10
Behavior of ice covers subjected to large daily flow and level fluctuations
Energy Technology Data Exchange (ETDEWEB)
The stability of a solid ice cover subjected to rapidly varying water levels and discharge was investigated. The support from the bank limits the stress in the ice cover and consequently bank contact must be maintained to ensure ice cover stability. An analysis was required of the stability of ice hinges, a flexible connection between a solid ice cover and the riverbank. Phase II and phase III of the research involved a field study of the Peace River, investigating the evolution of ice hinges with water level variation, from initial ice cover cracking parallel to the banks, to a fully developed hinge. A test program of midwinter discharge variations was undertaken to gather specific data and measurements of ice hinge link length, ice thickness, hinge joint behavior, riverbank geometry, and response of ice hinging to water level variation. As a result of the program, concepts developed throughout the study were confirmed, preliminary guidelines for hydroelectric ...
1984-11-01
BWR stability analysis at Brookhaven National Laboratory
Energy Technology Data Exchange (ETDEWEB)
Following the unexpected, but safely terminated, power and flow oscillations in the LaSalle-2 Boiling Water Reactor (BWR) on March 9, 1988, the Nuclear Regulatory Commission (NRC) Offices of Nuclear Reactor Regulation (NRR) and of Analysis and Evaluation of Operational Data (AEOD) requested that the Office of Nuclear Regulatory Research (RES) carry out BWR stability analyses, centered around fourteen specific questions. Ten of the fourteen questions address BWR stability issues in general and are dealt with in this paper. The other four questions address local, out-of-phase oscillations and matters of instrumentation; they fall outside the scope of the work reported here. It was the purpose of the work documented in this report to answer ten of the fourteen NRC-stipulated questions. Nine questions are answered by analyzing the LaSalle-2 instability and related BWR transients with the BNL Engineering Plant Analyzer (EPA) and by performing an ...
1991-12-31
Energy Technology Data Exchange (ETDEWEB)
Wind power is an increasingly significant renewable energy resource, producing no environmentally damaging C0{sub 2} emissions. The efficient production of electricity by wind turbines relies on aerodynamics: aerodynamics of wind turbines provides the fundamental solutions to efficient wind turbine design. Following a historical introduction, Part 1 of Aerodynamics of Wind Turbines is concerned with basic rotor aerodynamics, while Part 2 deals with structural aspects of the wind turbine and calculation of the loads on it. Topics covered include increasing mass flow through the turbine, performance at low and high wind speeds, assessment of the extreme conditions under which the turbine will perform and the theory for calculating the lifetime of the turbine. The classical Blade Element Momentum method is also covered, as are eigenmodes and the dynamic behaviour of a turbine. Aerodynamics of Wind Turbines is an essential reference for both ...
2000-06-15
Energy Technology Data Exchange (ETDEWEB)
Wind power is an increasingly significant renewable energy resource, producing no environmentally damaging CO2 emissions. The efficient production of electricity by wind turbines relies on aerodynamics. Aerodynamics of Wind Turbines provides the fundamental solutions to efficient wind turbine design. Following a historical introduction, Part 1 of Aerodynamics of Wind Turbines is concerned with basic rotor aerodynamics, while Part 2 deals with structural aspects of the wind turbine and calculation of the loads on it. Topics covered include increasing mass flow through the turbine, performance at low and high wind speeds, assessment of the extreme conditions under which the turbine will perform and the theory for calculating the lifetime of the turbine. The classical Blade Element Momentum method is also covered, as are eigenmodes and the dynamic behaviour of a turbine. Aerodynamics of Wind Turbines is an essential reference for both engineering ...
2001-01-01
Accident knowledge and emergency management
Energy Technology Data Exchange (ETDEWEB)
The report contains an overall frame for transformation of knowledge and experience from risk analysis to emergency education. An accident model has been developed to describe the emergency situation. A key concept of this model is uncontrolled flow of energy (UFOE), essential elements are the state, location and movement of the energy (and mass). A UFOE can be considered as the driving force of an accident, e.g., an explosion, a fire, a release of heavy gases. As long as the energy is confined, i.e. the location and movement of the energy are under control, the situation is safe, but loss of confinement will create a hazardous situation that may develop into an accident. A domain model has been developed for representing accident and emergency scenarios occurring in society. The domain model uses three main categories: status, context and objectives. A domain is a group of activities with allied goals and elements and ten specific domains have been investigated: ...
1997-03-01
ARIES-AT safety design and analysis
Energy Technology Data Exchange (ETDEWEB)
ARIES-AT is a 1000 MWe conceptual fusion power plant design with a very low projected cost of electricity. The design contains many innovative features to improve both the physics and engineering performance of the system. From the safety and environmental perspective, there is greater depth to the overall analysis than in past ARIES studies. For ARIES-AT, the overall spectrum of off-normal events to be examined has been broadened. They include conventional loss of coolant and loss of flow events, an ex-vessel loss of coolant, and in-vessel off-normal events that mobilize in-vessel inventories (e.g., tritium and tokamak dust) and bypass primary confinement such as a loss of vacuum and an in-vessel loss of coolant with bypass. This broader examination of accidents improves the robustness of the design from the safety perspective and gives additional confidence that the facility can meet the no-evacuation requirement under average weather ...
2006-01-15
ARIES-AT safety design and analysis
International Nuclear Information System (INIS)
ARIES-AT is a 1000 MWe conceptual fusion power plant design with a very low projected cost of electricity. The design contains many innovative features to improve both the physics and engineering performance of the system. From the safety and environmental perspective, there is greater depth to the overall analysis than in past ARIES studies. For ARIES-AT, the overall spectrum of off-normal events to be examined has been broadened. They include conventional loss of coolant and loss of flow events, an ex-vessel loss of coolant, and in-vessel off-normal events that mobilize in-vessel inventories (e.g., tritium and tokamak dust) and bypass primary confinement such as a loss of vacuum and an in-vessel loss of coolant with bypass. This broader examination of accidents improves the robustness of the design from the safety perspective and gives additional confidence that the facility can meet the no-evacuation requirement under average weather ...
2006-01-01
While feedback is important in theoretical models, we do not really know if it works in reality. Feedback from jets appears to be sufficient to keep the cooling flows in clusters from cooling too much and it may be sufficient to regulate black hole growth in dominant cluster galaxies. Only about 10% of all quasars, however, have powerful radio jets, so jet-related feedback cannot be generic. The outflows could potentially be a more common form of AGN feedback, but measuring mass and energy outflow rates is a challenging task, the main unknown being the location and geometry of the absorbing medium. Using a novel technique, we made first such measurement in NGC 4051 using XMM data and found the mass and energy outflow rates to be 4 to 5 orders of magnitude below those required for efficient feedback. To test whether the outflow velocity in NGC 4051 is unusually low, we compared the ratio of outflow velocity to escape velocity in a sample of AGNs ...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
To propose a new design concept of a nuclear reactor used in the space, research has been conducted on the conceptual design of a new nuclear reactor on the basis of the following three main concepts: (1) Thermionic generation by thermionic fuel elements (TFE), (2) reactivity control by rotary reflector, and (3) reactor cooling by liquid metal. The outcomes of the research are: (1) A calculation algorithm was derived for obtaining convergent conditions by repeating nuclear characteristic calculation and thermal flow characteristic calculation for the space nuclear reactor. (2) Use of this algorithm and the parametric study established that a space nuclear reactor using 97% enriched uranium nitride as the fuel and lithium as the coolant and having a core with a radius of about 25 cm, a height of about 50 cm and a generation efficiency of about 7% can probably be operated continuously for at least more than ten years at 100 kW only by reactivity control by rotary ...
1998-01-01
Energy Technology Data Exchange (ETDEWEB)
The main driver in ultra-shallow formation for the 65 nm technology node and beyond is to find solutions that both reduce boron transient enhanced diffusion and can be integrated in the CMOS process flow. To this end, many studies have recently focused on using co-doping techniques with fluorine and most recently with carbon. In most cases, one or both of these is co-implanted with a dopant specie in pre-amorphized silicon. In this work, we show a comparative study of fluorine or carbon co-implanted with low-energy boron to form source and drain extension junctions for PMOS devices. We will show that by a systematic optimization of germanium, boron, fluorine or carbon energies and doses, spike annealing technology can be extended to the 65 nm node. These results will be used to discuss how the different formed junctions offer potential solutions for either low-power or high-performance PMOS device fabrication.
2005-12-05
Energy Technology Data Exchange (ETDEWEB)
Two thirds of the neutrinos produced in the sun are not detected. In the last decade several experiments have allowed to give a limit to the neutrino mass and in some cases a negative value of the square of the mass was proposed. A negative value is inconsistent theoretically except in the case of tachyons which are particles allowed to travel faster than light. Consider neutrinos as tachyons could be a solution to find the answers to some of the riddles set by neutrinos. (A.C.)
1997-10-01
Energy Technology Data Exchange (ETDEWEB)
In this first quarterly technical report for DOE Contract No. DE-AC22-87PC79654, a description of the background, technology, and application is provided. The design and fabrication of advanced combustion chambers were completed during this period. Initial testing on both the bare metal and refractory lined advanced chambers were initiated. The units were tested initially with gas but primarily with coal. A Pittsburgh No. 8 pulverized coal was used for these test activities. Both advanced chambers pulsed well.
1987-12-31
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent