A compact heatexchanger pedestal array for augmenting heat transfer in a machine is disclosed. The compact heatexchanger pedestal array includes a wall having first and second surfaces. The first surface faces a heated flow path and the second surface p...
This paper deals with construction types of high temperature heatexchangers, their circulation loops and temperature differences. Most attention is given to gas dynamics, convective heat transfer, convection and radiant heat transfer interaction in high temperature heatexchangers. The ways of heat transfer augmentation and efficient heatexchanger construction are discussed.
We investigated phase transition of ilmenite-type AgSbO3 to pyrochlore by post-heat treatment and the synergy effect of the mixed phases of AgSbO3 on the photocatalytic activities to enhance the activities. The AgSbO3 with an ilmenite structure was prepared by a cation-exchange method. Phase transition from the ilmenite to pyrochlore occurred by proper control of post-heat treatment. The sample that was obtained by post-heat treatment of ilmenite-type AgSbO3 at 660^oC for 3h consisted of both of the ilmenite and pyrochlore phases, and the sample at 685^oC for 4h mainly consisted of the pyrochlore phase. Together with an increase in the ratio of the pyrochlore phase, the optical absorption spectra blue-shifted. The band gaps of single phases of the ilmenite and the pyrochlore were 2.4 and 2...
In this paper, numerical simulation of a concentric tube heatexchanger is presented to determine the convective heat transfer coefficient and friction factor in a smooth tube. Increasing the convective heat transfer coefficient can increase heat transfer rate in a concentric tube heatexchanger from a given tubular surface area. This can be achieved by using heat transfer augmentation devices. This work constitutes the initial phase of the numerical simulation of heat transfer from tubes employing augmentation devices, such as twisted tapes, wire-coil inserts, for heat transfer enhancement. A computational fluid dynamics (CFD) simulation tool was developed with CFX software and the results obtained from the simulations are validated with the empirical correlations for a smooth ...
The behavior of air flows in complex heatexchanger passages is reviewed with a focus on the heat transfer effects of boundary-layer development, turbulence, spanwise and streamwise vortices, and wake management. Each of these flow features is discussed for the plain, wavy, and interrupted passages found in contemporary compact heatexchanger designs. Results from the literature are used to help explain the role of these mechanisms in heat transfer enhancement strategies.
The development of a gas-operated diffusion absorptionheat pump for the heating of living spaces is described. By various improvement an energy efficiency of the prototypes of 1.5 was achieved. Structural alterations led to a lower overall height and lower production costs. The CFCs used in electric heat pumps were replaced by environmentally neutral ammonia. Compared with conventional gas heating systems, the CO2 output could be reduced by more than 30%. figs., tabs.
A method is described of controlling an anodic protection system in a heatexchanger comprising: (a) installing at least one cathode within the heatexchanger, at least one cathode being aligned with the longitudinal axis of the heatexchanger and extending substantially along the length of the heatexchanger; (b) installing a first reference electrode within and at one end of the heatexchanger, the first reference electrode having a first controller having a set point for control and a power supply having an output creating an electrical potential between at least one cathode and the heatexchanger; (c) measuring the electrical potential of the heatexchanger with the first reference electrode; ...
The patent describes a method for repairing leakage-causing cracks and fissures in a cryogenic heatexchanger. It comprises: reducing the interior pressure of the heatexchanger to a level which does not exceed the external pressure upon the hear exchanger while maintaining the temperature of the heatexchanger at a low level relative to the ambient external temperature; applying a curable liquid filler composition to the surface of the heatexchanger proximal the leakage site for seepage into the cracks and fissures located at the leakage. The composition upon a relatively short period of cure at low temperature forming a solid material which fills the cracks and fissures; curing the filler composition; and, applying a sealant composition to the surface of the heat ...
This paper presents a set of heuristics useful for optimal design of heat-exchange networks and integrated heat and power systems. These heuristics consolidate other approaches reported in the literature in a formalism useful for design purposes.
The thermal-hydraulic performance in periodic frosting conditions is experimentally studied for the parallel-flow parallel-fin heatexchanger, henceforth referred to as a PF{sup 2} heatexchanger, a new style of heatexchanger that uses louvered bent fins on flat tubes to enhance water drainage when the flat tubes are horizontal. Typically, it takes a few frosting/defrosting cycles to come to repeatable conditions. The criterion for the initiation of defrost and a sufficiently long defrost period are determined for the test PF{sup 2} heatexchanger and test condition. The effects of blower operation on the pressure drop, frost accumulation, water retention, and capacity in time are compared under the conditions of 15 sequential frosting cycles. Pressure drop across the heat ...
The effect of heat transfer is described from heatexchange tubes of a horizontal steam generator on the distribution of primary water to the individual tubes of the tube bundle. It is shown that in a broad interval of mass flow rates and lengths of heatexchange tubes, the simplified method of calcualtion, i.e., calculation of the distribution of primary water into heatexchange tubes neqlecting the changes of physical properties of water along the heatexchange tubes, will yield sufficiently accurate results.
The effect of heat transfer is described from heatexchange tubes of a horizontal steam generator on the distribution of primary water to the individual tubes of the tube bundle. It is shown that in a broad interval of mass flow rates and lengths of heatexchange tubes, the simplified method of calcualtion, i.e., calculation of the distribution of primary water into heatexchange tubes neqlecting the changes of physical properties of water along the heatexchange tubes, will yield sufficiently accurate results. (author).
The theoretical analysis of a partially-ionized hydrogen gas flow (gas temperatures of approximately 10,000 to 20,000 K) through a particular class of magnetohydrodynamic (MHD) generators and the preliminary design of these MHD generators as open cycle, electric power supplies are performed. Analysis of the gas flow through these ultra-high temperature MHD generators requires a coupled gas dynamics/radiative heat transfer solution. Gas dynamics are modeled by a set of quasi-one-dimensional, nonlinear differential equations which account for friction, convective and radiative heat transfer and the interaction between the ionized gas and applied magnetic field. Radiative heat transfer is modeled using non-gray, absorbing-emitting two- and three-dimensional P-1 approximations which permit an arbitrary variation of the spectral absorption coefficient with frequency. Gas dynamics and radiative ...
''Hybrid'' hydrogen storage, where hydrogen is stored in both the solid material and as a high pressure gas in the void volume of the tank can improve overall system efficiency by up to 50% compared to either compressed hydrogen or solid materials alone. Thermodynamically, high equilibrium hydrogen pressures in metal-hydrogen systems correspond to low enthalpies of hydrogen absorption-desorption. This decreases the calorimetric effects of the hydride formation-decomposition processes which can assist in achieving high rates of heatexchange during hydrogen loading-removing the bottleneck in achieving low charging times and improving overall hydrogen storage efficiency of large hydrogen stores. Two systems with hydrogenation enthalpies close to -20kJ/mol H2 were studied to investigate the h...
Sheep red blood cells (SRBCs) were labelled with a concanavalin A-luminol-bovine serum albumin conjugate specific for the transmembrane anion transport protein (Band 3) and exposed to 2450-MHz continuous-wave microwave radiation at an average specific absorption rate of 91W/kg for 10 min. The temperature was held constant at 25, 37, 40, 42, or 45C with an airflow heat-exchange system. Following exposure to microwave or air heating, the decrease in residual base-activated chemiluminescence (CL) of the SRBCs was measured as an indication of infield oxidase activity. Air heating resulted in a significant decrease in residual CL at temperatures above 37C (74% decrease at 45C). Microwave radiation inhibited the decline in residual CL above 37C. At 45C the inhibition was 40%. The results suggest microwave radiation either reversibly altered the thermodynamics of oxygen binding to haemoglobin or failed to ...
The flow distribution through a plate-fin heatexchanger is studied by using a computational fluid dynamics (CFD) code, FLUENT. The flow distribution through any heatexchanger affects its performance. In designing a heatexchanger, it is assumed that the fluid is uniformly distributed through the heatexchanger core. In practice, however, it is impossible to distribute fluid uniformly, because of an improper inlet configuration, imperfect design, and a complex heat transfer process. The CFD simulation of the flow distribution in the header of a conventional plate-fin heatexchanger is presented. It is found that the flow maldistribution is very serious in the y-direction of the header. A modified header is proposed and simulated using CFD. The modified ...
Experience has shown that a list of tips provides designers and engineers with an effective guide in their areas of duties and concern. This list contains new and rare information on heatexchangers and heat recovery systems. The information presented can be used effectively with personal computers and pocket calculators and also conveniently translated into computer programs and nomographs.
A heat transfer (condenser) of a domestic freezer was tested in a vertical channel in order to study the influence of the chimney effect in the optimization of the heat transfer coefficient. The variation of the opening of the channel, position and the heating power of the heatexchanger in the heat transfer coefficient was considered. The influence of the surface emissivity on the heat transfer by thermal radiation was studied with the heatexchanger testes without paint and with black paint. The air velocity entering the channel was measured with a hot wire anemometer. In order to evaluate the chimney effect, the heatexchanger was testes in a open ambient. This situation simulates its operational conditions when installed on the freezer system. The ...
Compact heatexchangers are being increasingly considered for condensation applications in the process, cryogenic, aerospace, power and refrigeration industries. In this paper, different configurations available for condensation applications are analyzed and the current state-of-the-knowledge for the design of compact condensers is evaluated. The key technical issues for the design and development of compact heatexchangers for condensation applications are analyzed and major advantages are identified. The experimental data and performance prediction methods reported in the literature are analyzed to evaluate the present design capabilities for different compact heat-exchanger configurations. The design flexibility is evaluated for the development of new condensation applications, including integration with other process equipment.
The invention concerns a device for the energy-saving heating of fuel in the supply pipe to an internal combustion engine to regain energy from the fuel itself, particularly but not exclusively for a Diesel engine. A part of the quantity of heat added to the fuel between the tank and the injection nozzles is given up by excess fuel not to the tank, but to the fuel lifted upstream of the injection pump. The device is characterised by the fact that it has a heatexchanger, which absorbs heat from the fuel at the level of the injection pump or upstream of it, and takes this to the fuel above the injection pump. The heatexchanger is preferably mounted upstream of a filter and close to it. A bridging pipe, which may be integrated in the heatexchanger, permits the heat ...
This textbook contains the following main topics: Heat conductivity, convection, condensation and evaporation, radiation heat transfer and heatexchangers. It includes the physical foundations for all these aspects and many examples. (orig.)
Lithium isotopes are used as the raw material of tritium which is the fuel for fusion power generation and the material for fusion reactors, accordingly those are indispensable for future nuclear fusion power generation. As for boron isotopes, the neutron absorption corss section is very large, therefore, they are used for shielding neutrons and controlling fast neutron reactors. In order to further develop the utilization of nuclear power, it is important to develop the technology for separating and refining light element isotopes in large amount. In fiscal year 1995, the relation of the ion sieve characteristics of inorganic ion exchanger and the behavior of lithium isotope separation was examined. The behavior of forming boron complex of polyol amine was examined by B-11 NMR. These experiments and the results are reported. It was shown to be feasible that lithium is adsorbed from seawater, and isotopes are concentrated. Titanium phosphate ...
A cooling system for rejecting waste heat consists of a cooling tower incorporating a plurality of coolant tubes provided with cooling fins and each having a plurality of cooling channels therein, means for directing a heatexchange fluid from the power plant through less than the total number of cooling channels to cool the heatexchange fluid under normal ambient temperature conditions, means for directing water through the remaining cooling channels whenever the ambient temperature rises above the temperature at which dry cooling of the heatexchange fluid is sufficient and means for cooling the water. 5 figs.
This paper details the design, construction and testing of a bayonet tube heatexchanger for use in the process industry and potentially as part of an externally fired combined cycle. Detailed analysis of the system has been undertaken, in particular on the tube side. The data is reported in terms of temperature, pressure, heat gain and heatexchanger effectiveness, over a range of Reynolds numbers and shell side mixture ratios. Much of the heat gained by the tubes is in the annular flow of the bayonet tube. Overall the effectiveness of this system could exceed 70%. (Author)
This book contains nine selections. Some of the titles are: High Heat-Flux, Forced-Convection Heat Transfer for Tubes with Twisted-Tape Inserts; Heat Transfer Augmentation by Interrupted Surfaces - Experimental Consideration; Turbulent Flow Heat Transfer from Externally Roughened Tubes in Axial Flow in Concentric Pipe HeatExchangers; and Heat Transfer Enhancement of Turbulent Flow in Pipes with an Internal Circular Rib.
This book contains nine selections. Some of the titles are: High Heat-Flux, Forced-Convection Heat Transfer for Tubes with Twisted-Tape Inserts; Heat Transfer Augmentation by Interrupted Surfaces - Experimental Consideration; Turbulent Flow Heat Transfer from Externally Roughened Tubes in Axial Flow in Concentric Pipe HeatExchangers; and Heat Transfer Enhancement of Turbulent Flow in Pipes with an Internal Circular Rib.
RODbaffle heatexchanger is a kind of shell-and-tube heatexchanger with eminent performance. Because of the characteristics of tube bundle support structure, fluid flow on shellside is longitudinal and periodical, and fluid flow is of symmetry in landscape orientation. According to the fluid flow characteristics on shellside and ignoring the impact of inlet, outlet and shell wall, a periodic flow unit duct was taken as the simplified model of the shellside to perform numerical simulation by using CFD code, FLUENT. It was found that the both errors in magnitude of the main fluid velocities and heat transfer coefficients between results of simulation and that of experiment or correlations are less than 10%, and the errors of pressure drop between simulation and correlation are no more than 20%. The detailed characteristics and relation of fluid flow and heat ...
In order to evacuate the residual power in a nuclear reactor, a thermal valve system is presented for the modification of the heatexchange conditions at the pool exchanger level, which avoids the use of mechanical valves on the pipes. The system involves a vessel containing the exchanger, with openings at the upper end of the vessel and means for feeding the fluid at the lower end, and means for controlling the opening width.
In the course of this year six local exchange offices with alternative heating and hot water plants were started up in Switzerland. They are all of the same building type, designed for not more than 1000 telephone subscribers and for the same architectural conditions. However, the buildings are situated in different areas of the country and are thus subject to different environmental conditions. Solar collectors supplemented by electricity boilers are fitted to two of these objects. Heat pumps are operated in two other exchange offices while the last two are equipped with electric heating devices. For purposes of comparison two new test plants of the same size with oil heating devices are set up.
An improved hybrid solar/combustion powered receiver of the type having an insulated housing with a front end and a rear end, a heatexchanger positioned adjacent the rear housing end for extracting heat energy out of the receiver, the insulated housing surrounding the heatexchanger and forming a receiver cavity, the housing also including an aperature having an aperture axis, the aperture located in the front housing end for admitting solar radiation to the cavity to impinge upon the heatexchanger, and a plurality of gas burners to provide combustion gases within the receiver.
The energy flux distribution at the aperture of cavity receivers is an important parameter that characterizes the performance of point-focusing solar concentrators. Together with simplifying assumptions about cavity absorptance, emittance, and convective losses, good estimates of the dish-receiver collection efficiency as a function of incident flux and effective cavity temperature can be obtained. For detailed design of cavity receivers, however, it is necessary to determine the incident flux distribution on the interior surfaces. This information is needed ultimately to determine the resulting energy fluxes to the working fluid, temperature distributions within the cavity, and receiver performance. Knowing the incident flux distributions provides the designer with insights such as where hot-spots are likely to occur, where heatexchange surfaces are needed, and where more detailed analysis might be warranted. Solar ...
A passive heatexchange enhancement structure which operates by free convection includes a flat mounting portion having a plurality of integral fins bent outwardly from one side edge thereof. The mounting portion is securable around a stovepipe, to a flat surface or the like for transferring heat from the pipe through the fins to the surrounding air by rotation-enhanced free convection.
The leak before break (LBB) concept is difficult to apply to a structure with a thin tube that is immersed in a water environment. A heatexchanger in a nuclear power plant is such a structure. The present paper addresses an application of the LBB concept to a heatexchanger in a nuclear power plant. The minimum leaked coolant amount containing the radioactive material which can activate the radiation detector device installed near the heatexchanger is assumed. The postulated initial flaw size that cannot grow to the critical flaw size within the time period to activate the radiation detector is justified. In this case, the radiation detector can activate the warning signal caused by coolant leakage from initially postulated flaws of the heatexchanger. The nuclear plant can safely shutdown when this occurs. Since the ...
A comprehensive presentation is made of state-of-the-art configurations and design methodologies for heat transfer devices applicable to industrial processes, automotive systems, air conditioning/refrigeration, cryogenics, and petrochemicals refining. Attention is given to topics in heatexchanger mechanical design, single-phase convection processes, thermal design, two-phase exchanger thermal design, heat-transfer augmentation, and rheological effects. Computerized analysis and design methodologies are presented for the range of heat transfer systems, as well as advanced methods for optimization and performance projection.
The refrigerant two-phase flows in a distributor and a simulated plate heatexchanger with a single passage used in a compression-type refrigerator were visualized by real-time neutron radiography. For a distributor, the liquid fraction in the each tube was measured by some image processing method. On the other hand, for a plate heatexchanger, the two-dimensional distribution of void fraction was measured quantitatively by the umbra method. As a result, it was shown that the dynamic behaviors of refrigerant at the inlet of the section strongly affected on the performance, that is, a distribution performance of a distributor and a liquid distribution in a plate heatexchanger. (author)
Tube failures due to excessive flow-induced vibration must be avoided to assure the reliable performance of heatexchangers. Such components must be thoroughly analysed for vibration at the design stage. Several flow-induced vibration mechanisms are possible. In this paper, particular attention is given to fluidelastic instability of tube bundles subjected to liquid and two-phase cross-flow. The performance of ten operating heatexchanger components is reviewed to validate our recommended vibration analysis guidelines. Both tube failure histories and satisfactory performances are considered. The results show that a fluidelastic instability constant K=3.3 is a reasonable design criterion. (auth).
A solar energy desalination process utilizing solar radiation directly for the evaporation of salt water is described. Ambient air takes on water vapor as the air passes through an evaporative medium. It is then directed between a saline water-covered, solar absorbing surface and a solar collecting housing. The resulting heated and moisture-saturated air is cooled in a heatexchange means where condensation of fresh water occurs. Simultaneously, cool salt water is utilized as the cooling water in the heatexchange means, and takes on the heat of condensation given up by the condensing vapor. The heated salt water from the heatexchange means is partially directed over the solar absorbing surface, and at least a portion of it is also directed to wet the evaporative medium. Several optional ...
A simple tube-in-tube heatexchanger system for thermal energy storage employing stearic acid as PCM has been investigated. The performance and heat transfer characteristics of such a system were studied. Phase transition temperature range and times were measured and the speed of the phase transition front was computed. The melting front was found to move in the radial direction inward as well as in the axial direction from the top toward the bottom of the phase change material PCM tube. The speed of the melting front is enhanced by a convection heat transfer mechanism in the melted PCM. The heat transfer rate and, consequently, phase transition time can be altered by changing the water inlet temperature to the heatexchanger. In addition, a faster phase transition is realized by placing the heat ...
Theoretical investigations of fatty acids as a phase change material (PCM) for energy storage system have been conducted in this study. The selected fatty acids were capric acid, lauric acid, myristic acid, palmitic acid and stearic acid. For the two-dimensional simulation model based on the enthalpy approach, calculations have been made for the melt fraction with conduction only. Glass, stainless steel, tin, aluminium mixed, aluminium and copper were used as heatexchanger materials in the numerical calculations. Theoretical results show that capric acid was found good compatibility with latent heat storage system. The large value of thermal conductivity of heatexchanger materials did not make significant contribution on the melt fraction. (author)
... The other standards in this group deal with heatexchangers, insulation, marking, valves, hydraulic cleanliness, storage of LPG, and centrifugal fire ...
Currentless plasma in Uragan-3M (U-3M) is produced and heated by absorption of RF power in the region of Alfven waves (AW). The process of plasma heating was explained in (2) as a result of Cherenkov absorption of energy of the fast (EM) and slow (kinetic Alfven) waves by electrons and turbulent ion heating due to excitation of short wave ion Bernstein waves (IBW). In this report we present results of studies of plasma density fluctuations showing existence of a narrow bands near the frequencies of ? ? n?ci (n=1,2,3).
Heat transfer has emerged as a leading-edge technology supporting the rapid pace of developments in science and engineering ranging from energy production to electronic cooling. Subjects covered at the 6th UK National Conference on heat transfer held at Edinburgh from 15-16 September 1999 include: convection; boiling and evaporation; condensation; numerical techniques; heatexchangers; radiation and combustion; conduction; two-phase flow and heat transfer augmentation. Fifteen of the papers are abstracted here.
A numerical study has been conducted to examine the heat transfer from a metal foam-wrapped solid cylinder in cross-flow. Effects of the key parameters including the free stream velocity and characteristics of metal foam such as porosity, permeability, and form drag coefficient on heat and fluid flow are examined. Being a determining factor in pressure drop and heat transfer increment, the porous layer thickness is changed systematically to observe that there is an optimum layer thickness beyond which the heat transfer does not improve while the pressure drop continues to increase. This has been verified by the application of Bejan?s Intersection of Asymptotes method. Results have been compared to those of a finned-tube heatexchanger to observe much higher heat transfer rate with reasonab...
This paper describes a reactor design to facilitate a room-temperature nuclear fusion/fission reaction to generate heat without generating unwanted neutrons, gamma rays, tritium, or other radioactive products. The room-temperature fusion/fission reaction involves the sequential triggering of billions of single-molecule, "6LiD 'fusion energy pellets' distributed in lattices of a palladium ion accumulator that also acts as a catalyst to produce the molecules of "6LiD from a solution comprising D_2O, "6LiOD with D_2 gas bubbling through it. The D_2 gas is the source of the negative deuterium ions in the "6LiD molecules. The next step is to trigger a first nuclear fusion/fission reaction of some of the "6LiD molecules, according to the well-known nuclear reaction: "6Li + D #-># 2"4He + 22.4 MeV. The highly energetic alpha particles ("4He nuclei) generated by this nuclear reaction within the palladium will cause shock and vibrations in the palladium lattices, leading ...
This patent describes a nuclear system comprising a containment airspace in which a nuclear reactor pressure vessel is disposed there being a reactor core within the pressure vessel. It comprises a heatexchanger elevated a distance above the pressure vessel; a pool of water surrounding the heatexchanger; means for venting the pool of water to an environment outside the containment; a heatexchanger entry conduit within the containment, the entry conduit having an open lower end communicating with the containment space, and an upper end connected to the heatexchanger, water-containing heated fluid present in the containment airspace incident a pressure vessel loss of coolant event entering and flowing through the entry conduit into the heatexchanger for ...
This project dealt with use of condensing heatexchangers to recover water vapor from flue gas at coal-fired power plants. Pilot-scale heat transfer tests were performed to determine the relationship between flue gas moisture concentration, heatexchanger design and operating conditions, and water vapor condensation rate. The tests also determined the extent to which the condensation processes for water and acid vapors in flue gas can be made to occur separately in different heat transfer sections. The results showed flue gas water vapor condensed in the low temperature region of the heatexchanger system, with water capture efficiencies depending strongly on flue gas moisture content, cooling water inlet temperature, heatexchanger design and flue gas and cooling water flow ...
Late 1994, the Geothermal Heat Pump Consortium (GHPC) was launched as a non-profit collaborative effort between the United States Department of Energy, US electric utilities and the GeoExchange (geothermal heat pump) industry to make ''geothermal heat pumps'' a significant component of the HVAC industry and avoid 1.5 million metric tons of carbon equivalent per year. The goal was to create a self-sustainable GeoExchange market. This report offers a summary of some of the lessons learned and an overview of some of the programs major accomplishments.
Compact heatexchangers have traditionally found wide application in the transportation industry, where they are used as evaporators and condensers in vapor compression cycles for air conditioning and refrigeration. Such heatexchangers possess numerous attractive features including high thermal effectiveness, small size, low weight, design flexibility, and pure counterflow, and they can accommodate multiple streams. Today, there is a widespread interest in expanding the range of application of compact heatexchangers to include phase-change heat transfer in the process industries, among others. An overall objective of this effort is to provide the basis for establishing design technology in this area. In the present study, small channel flow boiling heat transfer was extended to a rectangular channel (4.06 {times} 1.70 ...
The thermal performance of an automotive radiator plays an important role in the performance of an automobile's cooling system and all other associated systems. For a number of years, this component has been given little attention with very little changing in its manufacturing cost, operation and geometry. As opposed to the old tubular heatexchanger configurations used in automotive radiators, plate heatexchangers currently form the backbone of today's process industry with their advanced performance reaching levels the designers of tubular heatexchangers can only dream of. The aluminium roll-bonding technique widely used in manufacturing the cooling compartments for domestic refrigeration units is one of the cheapest methods for heatexchanger manufacturing. Using this technique, it is possible to ...
Three typical Japanese coals of non-coking coal, coking coal and anthracite were heat-treated with KOH, and change in their pore structure was examined by absorption of N2, X-ray diffraction and TEM observation. In addition, the relation between a coal rank and pore structure was also studied by absorption experiment of N2. In experiment, the mixture of coal and KOH in a nickel holder was heat-treated in N2 gas flow at heating rate of 2{degree}C/min, and held at a fixed temperature for one hour. To clarify the pore structure, N2 absorption isotherms were measured at -196{degree}C under nearly 76cmHg using a commercially available full-automatic absorption measurement equipment. Based on the X-ray diffraction and TEM observation results on activated coals, the relation between the N2 absorption and pore structure was ...
This paper describes various eddy current probes, and their performance, which were developed at the Chalk River Laboratories of Atomic Energy of Canada. Included are probes for detecting defects at tubesheet regions in heatexchanger tubes, defects at expansion-transition regions in finned tubes, and defects in ferromagnetic tubes. All of these probes can be used with conventional commercially available instruments. (author).
Thermogalvanic corrosion of St3 steel in a temperature range from 25 to 50{degrees}C with a 3.84{degrees}C/cm gradient was studied in a neutral media flow. It is shown that the thermogalvanic effect on the pitting corrosion of water-cooled heatexchangers is decisive but dual. Depending on the composition of the cooling medium, thermogalvanic corrosion may either enhance (0.5 M NaCl) or inhibit (tap water) pitting corrosion.
A simple and effective method is presented for the sizing and passage apportionment of multistream plate-fin heatexchangers. Methods for passage arrangement are discussed, and it is shown that a symmetric or mixed passage arrangement is more efficient than a segregated arrangement. A method for assessing the relative merits of various passage arrangements is presented. The use of the methods is illustrated through a worked example.
Here the authors try to dissolve some commonly held misconceptions about the operation of eddy current probes used for inspecting heatexchanger tubes. With the help of computer model results, the authors demonstrate that, for optimized operation, absolute/differential probes should be operated with coil current flowing in phase with another. This month's feature should be of interest to researchers as well as for NDT field personnel.
It is desirable to avoid vibration problems by following appropriate guidelines and specifications at the design stage. Accordingly, design specifications were developed to prevent tube failures due to vibration in nuclear steam generators and liquid heatexchangers. These specifications are outlined in this report. (author). 14 refs., 2 figs.
This heatexchanger is a critical step in the development of the Externally Fired Combined Cycle power system, a direct-coal combustion power plant (gas turbine). SiC is the only material with the needed resistance to creep, thermal shock, and oxidation; however a protective coating is needed. Ten candidate materials were identified: alumina-based materials, materials stable with SiO, and low expansion materials. An initial screening study should be performed.
Radian received twelve sections of heatexchanger tubing from the Magma Electric Company's 10MW(e) East Mesa binary geothermal power plant. Three tube sections were received from each of four shell and tube heatexchangers (HX1, Hx6, HX8, and Hx10) of the isobutane vaporizer train. All samples were taken from the upper few rows of tubes. Two months later, four more tube sections were received. These four sections were taken from the lower rows of heatexchangers 1, 6 (two sections), and 10. Radian was requested to investigate the cause of severe pitting failure of these heatexchanger tubes. This report is part of a continuing DOE effort to gain insight into the service life of component materials employed in geothermal energy utilization.
Fins serve as heat transfer augmentation features in solar air heaters; however, they increase pressure drop in flow channels. Pin fins are relatively good heat transfer augmentation features with superior aerodynamic performance, and as a result find application in some solar air heaters. The exergy optimization method is employed in sizing the pin fin. Results indicate that high efficiency of the optimized fin improves the heatabsorption and dissipation potential of a solar air heater. With optimum fin efficiency and superior absorptive coating quality, useful energy losses can be minimized. Some important observations pertinent in design are made. (author)
The heat transfer augmentation is reviewed in view of high temperature heatexchangers illuminating the contribution of radiative heat transfer. A number of means and/or devices are presented as well as the sophisticated concept which will be promoted to the extended applications in matured industries such as iron and steel, oir refinery, petro-chemical. It should be emphasized that the more creative and innovatory technology has to be promoted in order to stimulate and refresh the foregoing industries, recognizing the increasing importance of the energy resources.
An experimental study was undertaken to determine for the turbulent regime the heat transfer and fluid flow characteristics of a heatexchange array of unperforated, and perforated brass plates with 33% of the plate area open. In both cases, the plates were aligned parallel to the flow direction. For the flow conditions examined, the results showed enhancement of heat transfer and friction factor for the perforated array.
Active Process Water (APW) System, provided as unitized closed loop system in Tarapur Atomic Power Project Units-3 and 4, serves to remove heat from various heatexchangers. One of the important loads served by APW system is shutdown cooling heatexchangers and if APW shutdown is taken then reactor cannot be maintained in cold shutdown condition. It is estimated that after 7 days of reactor shutdown, if about 20% of the normal cooling flow to shutdown cooling heatexchangers is provided then along with keeping PHT in cold shutdown state, reactor components, moderator, end shield water, calandria vault water and calandria vault concrete temperature can be maintained within technical specification limits for extended duration. (author)
The fastest rate of growth in the space conditioning market has been attributed to the application of geothermal heat pumps to the industrial and commercial markets. The author reviews and provides examples of the three most popular components of a large geothermal heat pump system: geothermal earth coupling, heat pumps and heatexchangers, and building side terminals. These components are applied to three example geothermal installations: a library, an office building, and a school. Examples of energy use before and after the installation of a geothermal space conditioning system are summarized. General design and cost guidelines and comments on the use of geothermal heat pump in these and similar applications are discussed.
Total thermal resistance of ground heatexchanger (GHE) is comprised of that of the soil and inside the borehole. The thermal resistance of soil can be calculated using the linear source theory and cylindrical source theory, while that inside the borehole is more complicated due to the integrated resistance of fluid convection, and the conduction through pipe and grout. Present study evaluates heatexchange rate per depth of GHE by calculating the total thermal resistance, and compares different methods to analyze their similarities and differences for engineering applications. The effects of seven separate factors, running time, shank spacing, depth of borehole, velocity in the pipe, thermal conductivity of grout, inlet temperature and soil type, on the thermal resistance and heatexchange rate are analyzed. Experimental data from several real geothermal ...
Heat transfer enhancement in a heatexchanger tube by installing a baffle is reported. The effect of baffle size and orientation on the heat transfer enhancement was studied in detail. Three different baffle arrangements were considered. The results show that for the vertical baffle, an increase in the baffle height causes a substantial increase in the Nusselt number but the pressure loss is also very significant. For the inclined baffles, the results show that the Nusselt number enhancement is almost independent of the baffle inclination angle, with the maximum and average Nusselt number 120% and 70% higher than that for the case of no baffle, respectively. For a given baffle geometry, the Nusselt number enhancement is increased by more than a factor of two as the Reynolds number decreased from 20,000 to 5000. Simulations were conducted by introducing another baffle to enhance heat ...
A method is described for determination of aluminium, cadmium, cobalt, chromium, copper, calcium, magnesium, sodium, potassium, manganese, nickel, lead, strontium, zinc, titanium and vanadium in iron ore. After dissolution, a 1 gram sample of iron ore is applied to a column of AGI-X8 anion exchange resin (chloride form), in 100 ml of 7M HCl. Aluminium, chromium, calcium, magnesium, sodium, potassium, manganese, nickel, lead, strontium, titanium and vanadium are eluted with 7M HCl; iron, copper and cobalt are eluted with 0.5M HCl; cadmium and zinc are eluted with 2M HNO_3. Iron is subsequently removed from copper and cobalt by a solvent extraction with methyl isobutyl ketone. The elements are determined in the eluates by atomic absorption spectrometry, except for titanium and vanadium, which are determined spectrophotometrically.
The fully developed electrically conducting micropolar fluid flow and heat transfer along a semi-infinite vertical porous moving plate is studied including the effect of viscous heating and in the presence of a magnetic field applied transversely to the direction of the flow. The Darcy-Brinkman-Forchheimer model which includes the effects of boundary and inertia forces is employed. The differential equations governing the problem have been transformed by a similarity transformation into a system of non-dimensional differential equations which are solved numerically by element free Galerkin method. Profiles for velocity, microrotation and temperature are presented for a wide range of plate velocity, viscosity ratio, Darcy number, Forchhimer number, magnetic field parameter, heatabsorption ...
The object of the present study is to develop a high performance evaporator for automotive air conditioner. The experiment has been conducted on evaporative heat transfer coefficient inside a plate type heatexchanger with a sharp 180-degree turn flow. The test plates have different formed surface, cross-ribboned channel and elliptical-ribbed channel. Also experimental study has been performed to determine optimal design in elliptical-ribbed plate heatexchanger with different turn clearance. In addition to the above experiments, refrigerant behavior and surface temperature distribution in the plate heatexchanger were observed using color thermo viewer(infrared thermometer). In this experiment, working fluid was used R-12 and test conditions were as follows : (1) saturation pressure of 2,116 kg/cm{sup 2}, (2) mass fluxes of 40 to 70 ...
The X-ray photoacoustic spectra of copper and brass (64.7 wt.% Cu and 35.3 wt.% Zn) have been measured at XANES (X-ray absorption near-edge structure) regions using synchrotron radiation. These spectra were compared with optical density of X-ray spectra. It is shown that the information derived from XANES is also included in the X-ray photoacoustic spectrum which reflects the heat production processes in copper and brass. However, the results showed that the increases and changes of the photoacoustic signal were different from those of the X-ray absorption coefficient at XANES regions. (author).
This report contains a set of nomographs which can be used to estimate the average annual solar fraction for solar space and water heating at a large number of DOD facilities. The solar fraction estimated from the nomograph is in close agreement with F-Chart 3.0 and allows for variation of the following parameters: annual load, collector area, collector transmittance-absorptance coefficient, and collector overall loss coefficient.
A set of nomographs is presented which can be used to estimate the average annual solar fraction for solar space and water heating at a large number of DOD facilities. The solar fraction estimated from the nomograph is in close agreement with F-Chart 3.0 and allows for variation of the following parameters: annual load, collector area, collector transmittance-absorptance coefficient, and collector overall loss coefficient.
Heat transfer augmentation techniques (passive, active or a combination of passive and active methods) are commonly used in areas such as process industries, heating and cooling in evaporators, thermal power plants, air- conditioning equipment, refrigerators, radiators for space vehicles, automobiles, etc. Passive techniques, where inserts are used in the flow passage to augment the heat transfer rate, are advantageous compared with active techniques, because the insert manufacturing process is simple and these techniques can be easily employed in an existing heatexchanger. In design of compact heatexchangers, passive techniques of heat transfer augmentation can play an important role if a proper passive insert configuration can be selected according to the heatexchanger ...
A glass heat pipe is adapted for use as a solar energy absorber in an evacuated tube solar collector and for transferring the absorbed solar energy to a working fluid medium or heat sink for storage or practical use. A capillary wick is formed of granular glass particles fused together by heat on the inside surface of the heat pipe with a water glass binder solution to enhance capillary drive distribution of the thermal transfer fluid in the heat pipe throughout the entire inside surface of the evaporator portion of the heat pipe. Selective coatings are used on the heat pipe surface to maximize solar absorption and minimize energy radiation, and the glass wick can alternatively be fabricated with granular particles of black glass or obsidian.
This paper describes the field performance of air conditioning with an energy pile system, which was applied to the pile foundations of an actual building for the purpose of reducing the cost of the underground heatexchanger. First, the building for both office and residential use, for which a space heating and cooling system using friction piles was installed, was built in Sapporo in December 2000. Second, three tests were carried out to specify the design of a heatexchanger inside the pile, and a U-tube type underground heatexchanger was adopted from the viewpoint of energy efficiency and installation costs. Long-term space heating operation measurements indicated that the seasonal average temperatures of brine returning from the underground and pile surfaces were 2.4 and 6.7 deg C, respectively. The average ...
Basic experimental investigations were carried out with an aqueous solution of a mixture of KOH and NaOH for use as an absorbent in absorptionheat pumps. Due to its thermophysical properties this mixture allows temperature lifts from evaporator to absorber of more than 75 K (135 F) in a single-stage absorption chiller. Thermophysical and hydrodynamical properties of the solution were measured. Vapor-liquid-equilibrium data and specific heat capacities were determined for concentrations ranging from 35% up to 75% and temperatures up to 200 C (392 F). From these data the enthalpy of the solution was calculated. Additionally the crystallization temperatures, the density, and the viscosity of the solution were determined. The experimental equipment is described. The data are presented as polynomials and diagrams including experimental accuracy. An apparatus was constructed to measure ...
The merits of single stage absorptionheat pumps coupled to simple distillation for effluent treatment are discussed. An experimental integrated absorptionheat pump effluent purification system (IAHPEPS) was built and operated with water-lithium bromide as a working mixture. This unit has been used to raise the temperature and hence, the vapour pressure of the impure water contained in one vessel, to the point where pure water vapour will distil from impure effluent solution (tap water or brine) and condense in a second vessel used to collect pure water. Pure effluent production rates of between 0.5 and 4.3 kg h{sup -1} were obtained. The actual coefficient of performance (COP{sub A}) and the heat pump effectiveness varied from 1.1 to 1.4 and 0.58 to 0.72, respectively. The results from the small scale systems indicate the likely results from industrial scale units which could be ...
The concentric circular annular duct is a common geometry in many fluid flow and heat transfer devices. For the purpose of heat transfer augmentation, fins are often employed in the annular region, and such finned ducts find wide application in compact heatexchangers (5, 6). The analysis of flow and heat transfer in this geometry is, therefore, quite important from an engineering standpoint. For fully developed conditions, the problem has already been analyzed (7-10). However, no results are available for the developing flow in the entrance region. It is with this latter problem that the present paper is concerned.
A numerical analysis is made of the unsteady flow and heat transfer characteristics of mixed convection in a vertical block-heated channel with and without installing an inclined plate above an upstream block. Parameter studies including the inclined plate angle, Reynolds number (ranging from 260 to 530), and Grashof number (in the range of 0--3,200,000) on heat transfer performance have been explored in detail. The results show that the installation of an inclined plate in the vertical block-heated channel can effectively augment the blocks` heat transfer performance in the channel. This can be applied to heatexchangers.
Several heat transfer augmentation mechanisms contribute to the heat transfer augmentation around the stagnation point in the gas-solid two-phase impinging jet flow. Among those contributions, that of heatexchange was numerically analyzed and characteristically elucidated by the unsteady direct contact heat conduction at the time of impingement between the laden particles and heat transfer surface. In other words, if the contact time is short between the particles and heat transfer surface, the former is heated by heat stored in the latter as a heat capacity. In such a region, the heat quantity to be transferred to the particles changes by not only the thermal property value (heat capacity multiplied by heat ...
The Warm-Hot Intergalactic Medium (WHIM) arises from shock-heated gas collapsing in large-scale filaments and probably harbours a substantial fraction of the baryons in the local Universe. Absorption-line measurements in the ultraviolet (UV) and in the X-ray band currently represent the best method to study the WHIM at low redshifts. We here describe the physical properties of the WHIM and the concepts behind WHIM absorption line measurements of H I and high ions such as O VI, O VII, and O VIII in the far-ultraviolet and X-ray band. We review results of recent WHIM absorption line studies carried out with UV and X-ray satellites such as FUSE, HST, Chandra, and XMM-Newton and discuss their implications for our knowledge of the WHIM.
Reported in this paper are the theoretical and experimental studies, with regard to the effects of radiation between walls, conducted for the improvement of heat transfer characteristics of the circular duct in high temperature heatexchangers that operate through the medium of non-radiating gases at around 1,000"0C. To study the fundamental performance of the heat transfer augmentation, the experiment was carried out using a double tube at temperatures up to 900"0C. The outer tube in a double tube was selectively heated so as to give a uniform heat flux selected of 6.5 x 10"3 and 4.6 x 10"4 kcal/m"2.h, while the inner tube was used as a radiating surface to impart the radiation heat transmitted from the outer tube. Selectively preheated air was caused to flow in an annular passage at an inlet temperature selected within 100"0C to 400"0C and ...
The separation, concentration, and determination of trace elements in iron ores are described. After the sample has been dissolved, the iron is separated by liquid-liquid extraction with a liquid cation-exchanger, di-(2-ethylhexyl) phosphoric acid. The trace elements aluminium, cadmium, calcium, chromium, cobalt, copper, lead, magnesium, manganese, mercury, potassium, sodium, vanadium, and zinc are determined in the aqueous phase by atomic-absorption spectrophotometry.
A model for combined mass and heat transfer during nonisothermal gas absorption in a two-phase gas- liquid bubbly medium with a high gas content and/or large times of gas-liquid contact is suggested. Diffusion and thermal interactions between bubbles is taken into account in the approximation of a cellular model of a bubbly medium whereby a bubbly medium is viewed as a periodic structure consisting of identical spherical cells with periodic boundary conditions at a cell boundary. Distribution of concentration of dissolved gas, temperature distribution in liquid and coefficients of mass and heat transfer during nonisothermal absorption of a soluble pure gas from a bubble by liquid are determined. In the limiting case of absorption without heat release the derived formulas recover the expressions for isothermal absorption. (orig.). With 1 ...
The Geothermal Heat Pump (GHP) concept was originally developed in the 1940`s. Recently, because of increasing energy costs, utility interest, and the development of simple and durable ground source heatexchangers, GHP`s have gained international attention as a proven means of energy conservation and electrical peak power demand reduction. GHP systems require installation of a buried heatexchanger to utilize the nearly constant ground temperature making them more efficient than conventional air source heat pumps. However, the high installation cost for both residential and commercial applications is a major obstacle to their market penetration. Sandia National Laboratories (SNL) through its sponsors, the Department of Energy (DOE), and the Department of Defense (DOD), has embarked on a research program to find ways to reduce GHP installation costs and improve ...
The melting unit, consisting of a water-cooled cupola furnace, afterburner, heatexchanger, air preheater, consumes most of the supplied energy in the rockwool process. The report maps the energy flows and defines factors of merit according to thermodynam...
We report the experimental and theoretical results on the anisotropies in the magnetic properties and x-ray absorption spectra of single-crystal LiFePO4. A mean-field theory is developed to explain the observed strong anisotropies in Lande g-factor, paramagnetic Curie temperature, and effective moment for LiFePO4 single crystals. The values of the in-plane nearest- and next-nearest-neighbor spin exchange (J1 and J2), interplane spin exchange (J{perpendicular}), and single-ion anisotropy (D), obtained recently from neutron scattering measurements, are used for calculating the Curie temperatures with the formulas derived from the mean-field Hamiltonian. It is found that the calculated Curie temperatures match well with that obtained by fitting the magnetic susceptibility curves to the modified Curie-Weiss law. For the polarized Fe K-edge x-ray absorption spectra of single-crystal LiFePO4, a different ...
Iron concentration control in feedwater is one of the most important subjects in water chemistry. Especially for the BWR plants without 100% flow volume of hollow fiber filter (HFF), rather high iron concentration in feedwater is one of the big issues as this causes relatively high radiation dose rate in drywell area. Cation exchange resins especially used in the plants with partial flow rate of HFF are expected to have the important role of capturing iron in feedwater. For this purpose, we have investigated the effective method for using iron absorption characteristics of cation exchange resin. The Cation-Over Layer method (COL) in condensate demineralizers (CD) effectively utilizes these characteristics. In order to demonstrate a performance of the cation overlay method, we had applied this method for three CD vessels at Fukushima Daiichi NPP Unit 3 for testing purpose. The result of this actual plant test indicated that ...
A geothermal heat pump (GHP) system with three ground coils was installed in a residence in northern Idaho with a portion of the ground heatexchanger wrapped around the residential septic tank. The septic coil provided a significant portion of the heating for the residence over the heating season. There was no evidence of the septic tank freezing up or failing to properly function. Utilizing a septic tank as a heat source for GHP systems is feasible design option if the septic tank is used on a full-time basis. However, the tank should be surrounded on all sides by a large amount of soil and/or insulated from the ground surface to ensure that ground temperatures near the tank remain warm during the winter.
A numerical analysis is performed to clarify the heat transfer characteristics of combined convection around the tubes which form a single row perpendicularly arranged to a forced flow in the direction of gravity. A boundary-fitted coordinate transformation technique is adopted to solve the governing equations numerically. It is found in the case of liquid sodium that gravity-induced flow gives no substantial effect to heat transfer augmentation in a low Reynolds number region while it can be sufficiently expected in the ordinary fluids in the same Reynolds number region. This means that such heat transfer augmentation as expected in ordinary fluids can not be realized when crossflow-type heatexchangers installed for decay-heat removal operates in a low Reynolds number region.
A numerical analysis is performed to clarify the heat transfer characteristics of combined convection around the tubes which form a single row perpendicularly arranged to a forced flow in the direction of gravity. A boundary-fitted coordinate transformation technique is adopted to solve the governing equations numerically. It is found in the case of liquid sodium that gravity-induced flow gives no substantial effect to heat transfer augmentation in a low Reynolds number region while it can be sufficiently expected in the ordinary fluids in the same Reynolds number region. This means that such heat transfer augmentation as expected in ordinary fluids can not be realized when crossflow-type heatexchangers installed for decay-heat removal operates in a low Reynolds number region. (author).
The thermal performance and phase change stability of stearic acid as a latent heat energy storage material has been studied experimentally. The thermal performance and heat transfer characteristics of the stearic acid were tested and compared with other studies given in the literature. In the present study, parameters such as transition times, temperature range and propagation of the solid-liquid interface as well as the effect of heat flow rate on the phase change stability of stearic acid as a phase change material (PCM) were studied. The experimental results showed that the melting stability of the PCM is better in the radial direction than in the axial direction. The variation in the melting and solidification parameters of the PCM with the change of inlet water temperature is also studied. We observed that while the heatexchanger tube is in the horizontal position, the PCM ...
A comparative assessment of five different heat transfer configurations for operation in compact heatexchangers is presented. The configurations under consideration are four standaed heatexchanger surfaces - two plain fin, an offset strip and a louvered fin geometry - and one surface with so called vortex generators for heat transfer augmentation. In the case of the standard surfaces, the basic performance characteristics in the form of heat transfer and friction data versus the Reynolds number have been taken from published experimental results. In the case of the vortex generator surface, the performance characteristics have been derived from a numerical prediction of the flow and temperature field in a closely spaced parallel plate channel with vortex generators in the form of delta wings mounted on the channel walls. In comparison to ...
At the Forschungszentrum Karlsruhe the HGF Strategy Fund project entitled 'Innovative Technology to Reduce Radiotoxicity' is performed which delivers an essential scientific contribution to the application oriented fundamental research for Accelerator Driven Systems (ADS). The addressed topics are in the areas of heavy liquid metal technology, thermalhydraulics and materials / corrosion. An ADS consists of three main components: an proton accelerator, a spallation target and a subcritical blanket. The strategic objective of an ADS is the transmutation of long-lived radioactive waste (plutonium, minor actinides and long-lived fission products) into short-lived isotopes or stable elements, thus closing the fuel cycle. The objective of one task of the HGF Strategy Fund Project is the numerical calculation of a closed spallation target module. In a consequent next step such a spallation target can be experimentally investigated at IKET and the numerical results can be validated. In this ...
A detailed component-based simulation model of a geothermal heat pump system has been calibrated to monitored data taken from a family housing unit located at Fort Polk, Louisiana. The simulation model represents the housing unit, geothermal heat pump, ground heatexchanger, thermostat, blower, and ground-loop pump. Each of these component models was tuned to better match the measured data from the site. These tuned models were then interconnected to form the system model. The system model was then exercised in order to demonstrate its capabilities.
A detailed component-based simulation model of a geothermal heat pump system has been calibrated to monitored data taken from a family housing unit located at Fort Polk, Louisiana. The simulation model represents the housing unit, geothermal heat pump, ground heatexchanger, thermostat, blower, and ground-loop pump. Each of these component models was 'tuned' to better match the measured data from the site. These tuned models were then interconnect to form the system model. The system model was then exercised in order to demonatrate its capabilities.
This paper describes the comprehensive modeling method of fluid and heat flows in the hydrological system. Based upon the concept that the hydrological system is composed of the air-water 2-phase fluids, and the rock phase, various natural processes are modeled including surface/subsurface 2-phase mass transfer, heatexchanges between fluid phases, between fluid and solid phases, and sensible/latent heatexchanges on the ground surface. A field-oriented numerical simulator is developed, in which a set of governing equations is solved for different variables on the surface and in subsurface regions, respectively. Results of an experimental study are presented, in which transient formulation of heatexchange between fluid/solid phases is examined through matching of the observation and calculated performances. (author)
This paper describes the comprehensive modeling method of fluid and heat flows in the hydrological system. Based upon the concept that the hydrological system is composed of the air-water 2-phase fluids, and the rock phase, various natural processes are modeled including surface/subsurface 2-phase mass transfer, heatexchanges between fluid phases, between fluid and solid phases, and sensible/latent heatexchanges on the ground surface. A field-oriented numerical simulator is developed, in which a set of governing equations is solved for different variables on the surface and in subsurface regions, respectively. Results of an experimental study are presented, in which transient formulation of heatexchange between fluid/solid phases is examined through matching of the observation and calculated performances. (author)
A gas-fired boiler plant comprises a burner bed extending over a flat surface and heatexchanger pipes arranged above the burner bed, parallel to the said surface. The heatexchanger tubes comprise pipes equipped with a pluraltiy of flat ribs which extend substantially radially from the said pipes and which are provided in space arrangement over the length of the said heatexchanger pipes. The ribs are provided with bent-off portions. The hot flue gases rising from the burner bed flow through the gaps formed between the said ribs and pipes. In order to improve both the convective heat transmission and the utilization of the radiant heat, the bent-over edges are inclined, at least partly, relative to the surface of said burner bed, the arrangement being selected in a manner to ensure that bent-over portions point towards ...
Oregon State University (OSU) and the Pacific Northwest National Laboratory (PNNL) were funded by the U.S. Department of Energy to conduct research focused on resolving the key technical issues that limited the deployment of efficient and extremely compact microtechnology based heat actuated absorptionheat pumps and gas absorbers. Success in demonstrating these technologies will reduce the main barriers to the deployment of a technology that can significantly reduce energy consumption in the building, automotive and industrial sectors while providing a technology that can improve our ability to sequester CO{sub 2}. The proposed research cost $939,477. $539,477 of the proposed amount funded research conducted at OSU while the balance ($400,000) was used at PNNL. The project lasted 42 months and started in April 2001. Recent developments at the Pacific Northwest National Laboratory and Oregon State University suggest that ...
A set of nomographs is provided which can be used to estimate the average annual solar fraction for solar space and water heating at a large number of DOD facilities. The solar fraction estimated from the nomograph is in close agreement with F-Chart 3.0 and allows for variation of the following parameters: annual load, collector area, collector transmittance-absorption coefficient, and collector overall loss coefficient.
The heating system of the `Centre integre de mecanique industrielle de la Chaudiere`, in Saint-Georges, Quebec, is based on a solar wall and a geothermal heat pump with a glycol/water mixture circulating in 44 wells that are 100 m deep. With installation costs below $25 per sq.m, more than 85 per cent of the heating needs of the 9500 sq.m centre were supplied by geothermal power. The geothermal heat pump is composed of a well field and two 211-kW cooling units, each equipped with four coiled compressors. In winter, heat is pumped from the earth and in summer, a heatexchanger with control valves allows to heat to be dumped back into the earth. The monitoring and simulation of the system proved its efficiency, considering the climatic conditions in Quebec. The annual consumption of geothermal heating ...
The purpose of the study is to investigate the heat transfer augmentation method for a wavy channel type heatexchanger. Experimental studies were carried out, by installation of flow guide-plates with simple structure, to clarify the effects on the augmentation whether the effects are brought by the flow acceleration or by the increase of intensity of turbulence due to the flow seperation, and to determine optimum shape of flow guide-plates. The shape and dimensions of the experimental apparatus are as follows; channel width H of 30 mm, rectangular section with breadth of 300 mm, wavy duct with a bend angle of 60/sup 0/ and straight pipe of 2H length. Air stream was flowed through the duct with Reynolds number of 1.7 x 10/sup 4/ only. As the results, following conclusions were obtained. (1) Wavy duct with large bend angle and without inserting flow guide-plates could not be expected large effects on the ...
An experimental study of forced convection heat transfer at the inner tube wall of a double pipe heatexchanger with coiled wire inserts as heat transfer augmentation devices was performed over a turbulent flow region. The test results from twelve augmented tubes with inserts of different combinations of wire diameters (0.813, 1.016 and 1.575 mm) and pitches (2.82, 3.63, 5.08 and 8.47 mm) indicate that the turbulence promoters studied improve heat transfer by a factor of 1.4 to 2.24 compared with a smooth tube, although at a cost of 10-30 times increase in friction factor. A formula for presenting dimensionless exergy losses in a tubular heatexchanger is derived first and then the thermohydrodynamic optimum instead of economic optimum is found by minimizing the exergy losses in the system. From the heat transfer ...
Simultaneously extracted metals (SEM) and acid volatile sulfide (AVS) show the potential for toxicity on the basis of their ratio. Accordingly, the authors spiked cadmium in a range for which Cd/AVS ratios were from 0.2 to 10 in the sediment with its weight about 8 kg in each batch. Dialysis samplers with a cation ion-exchange resin (Dowex 50W-X4) collection were used in a laboratory for the determination of free cadmium concentrations in pore water of the collected sediment. When equilibrium was reached among cadmium in pore water, sediment, and ion-exchange resin, cadmium exchanged onto resin phase was regenerated with 1 N hydrochloric acid (OPTIMA grade) and determined using an atomic absorption spectrophotometer (Zeeman 5000) with a graphite furnace accessory. Cadmium determined using the dialysis sampler is considered as free cadmium which is related to the metal bioavailability toward aquatic ...
A three-dimensional steady numerical computation was made for a component model of fin and tube type of compact heatexchangers situated in a uniform flow. In this study, in order to find a clue to design high-efficient heatexchangers, numerical computation was made in the case where two fences are attached on the plate fin surface and their geometrical effects such as their locations, their heights and their attack angles on flow and heat transfer characteristics were investigated especially in the low Reynolds number range. The effect of a hole, open in the plate fin behind the fence, on heat transfer and flow structures was also examined. This hole simulates the hole of the plate fin to be produced in practical application, when a fence is produced by punching from the original plain fin plate. Two fences with holes were found to show several important ...
The modeling and optimizing processes of a Ground Coupled Heat Pump (GCHP) with closed Horizontal Ground HeateXchanger (HGHX) are presented in this paper. After thermal modeling of GCHP including HGHX, the optimum design parameters of the system were estimated by minimizing a defined objective function (total of investment and operation costs) subject to a list of constraints. This procedure was performed applying Genetic Algorithm technique. For given heating/cooling loads and various climatic conditions, the optimum values of saturated temperature/pressure of condenser and evaporator as well as inlet and outlet temperatures of the water source in cooling and heating modes were predicted. Then, for our case study, the design parameters as well as the configuration of HGHX were obtained. Furthermore, the sensitivity analysis of change in the total annual cost of the system and ...
Heat transfer augmentation based on the process intensification concept in heatexchangers and thermal reactors has received much attention in recent years, mainly due to energy efficiency and environmental considerations. The concept consists of the development of novel apparatuses and techniques that, compared to those commonly used today, are expected to bring dramatic improvements in manufacturing and processing, substantially decreasing equipment size, energy consumption, and ultimately resulting in cheaper, sustainable technologies. The objective of this paper was to investigate the heat transfer characteristics of tubular thermal reactor using static mixing technology. Glycerin and water were used as the test fluids and water was used as the heating source. The results for heat transfer rate were strongly influenced by tube geometry and flow conditions.
In order to reduce the size and cost of heatexchangers, an air-side wavy fin-and-tube heat transfer surface with three-row tubes needs to be replaced by two-row tubes with some appropriate enhancing techniques. The major purpose of the present paper is to search for such new structure by numerical simulation. First, longitudinal vortex generators of Delta-winglet type are tried. The influence of number and of arrangement of the winglets on the performance of the heat transfer surface is studied in detail. The numerical results show that the fin with two winglets aligned spanwise in the front and rear of each tube (Fin W6) has higher heat transfer capability than other enhanced structures with vortex generators, but it still unable to meet the heat transfer requirement. Then a combination ...
The main features are presented of a computer programme for 3-D thermohydraulic and thermodynamic analysis of the PGV-1000 horizontal steam generator used at the Temelin NPP. The programme provides analyses of primary side hydraulics, heatexchange behavior and the steam generator secondary side thermohydraulics and thermodynamics. Given are calculated data on the circulation flow rate, void fraction, heat transfer dynamics and the swelled level. (Z.S.) 9 figs.
The concept of a multi-cavity volumetric solar receiver is very attractive for the profitability of certain of its characteristics such as high efficiency and economy. The absorber is based on a pack of small ceramic cavities which intercept and absorb the inherent high solar flux reflected from an array of mirrors. Atmospheric air acts as a coolant medium when it is drawn through the pack. A model for an overall heat transfer performance of the receiver is given and numerically solved.
Active Process Water (APW) system is provided as a unitized system in TAPP-3 and 4. Maintenance on APW system requires shutdown of this system. As shut down heatexchangers are fed by APW system; during APW system shutdown cold shutdown state cannot be maintained. Therefore safety analysis is done to optimize the duration of reactor shutdown (which means low decay heat) after which APW shutdown can be taken with minimum water supply to the shutdown heatexchangers. Based on this analysis, it is proposed in technical specification that APW system shutdown can be taken after 7 days of reactor shutdown with shutdown heatexchangers supplied with about 20 % of normal APW flow. With this configuration, PHTS, moderator, end shield, calandria vault water temperature can be maintained within limits. A design provision is made at TAPP-3 and 4 to ...
We report the results of characterization of nonlinear refractive index of the composite material produced by MeV Ag ion implantation of LiNbO{sub 3} crystal (z-cut). The material after implantation exhibited a linear optical absorption spectrum with the surface plasmon peak near 430 nm attributed to the colloidal silver nanoclusters. Heat treatment of the material at 500 C caused a shift of the absorption peak to 550 nm. The nonlinear refractive index of the sample after heat treatment was measured in the region of the absorption peak with the Z-scan technique using a tunable picosecond laser source (4.5 ps pulse width). The experimental data were compared against the reference sample made of MeV Cu implanted silica with the absorption peak in the same region. The nonlinear index of the Ag implanted LiNbO{sub 3} sample produced at five times less fluence is on ...
This paper describes the design, operation, and performance of an HVAC system installed as part of a project to demonstrate energy efficiency and environmental responsibility in commercial buildings. The systems installed in the 2180 m{sup 2} office building provide superior air quality and thermal comfort while requiring only half the electrical energy of conventional systems primarily because of the hydronic heating and cooling system. Gas use for the building is higher than expected because of longer operating hours and poor performance of the boiler/absorption chiller.
The paper presents a computer-aided analysis of the combined use of ventilation and structural heat capacity and insulation as a means of saving air-conditioning power in digital telephone exchanges. It is shown that such savings can be effected by increasing air change with outdoor cool air at night, and when feasible, also in daytime, through the air change unit, in a conventional airconditioning cycle. The total thermal time constant (TTTC) method of calculation used enables the evaluation of daily or seasonal heat-flow balance for a given indoor temperature, considering the tendency of the heat capacity of the building and of envelope components to flatten the fluctuations of this temperature.
The treatment of peat with the solutions of phosphoric, citric, and oxalic acids in concentrations of 10???4 and 10???2 mol/l at solid phase to liquid ratios of 1: 2.5 and 1: 5 increased the absorption of ammonia by 6.4???39.7%. The absorption of ammonia was higher than the concentration of doping ion-exchange groups by a factor of 5???2000. With the use of EPR and IR spectroscopy, it was found that this phenomenon was caused by the transformation of polyconjugation systems as a result of the interaction of acids with the organic matrix of peat by a macrocoordination mechanism, which also improved the technological characteristics of the resulting sorbents. The absence of the destruction of organic matter with the use of low concentrations of weak acids makes it possible to use these sorbe...
The aim of this work was to study the energy transfer mechanisms from the ligand to the central lanthanide ion of tetracycline-europium (Tc-Eu) complex. The absorption spectra of a EuCl{sub 3}.H{sub 2}O solution was measured and absorption cross-section of Eu{sup 3+} was estimated. The observed overlap predicts a resonant energy transfer from Tetracycline to Eu{sup 3+}. The microscopic parameter of energy transfer was obtained using the overlap integral calculation considering a dipole-dipole energy transfer mechanism and results were compared considering an energy transfer by exchange. In this work, we report also the optical properties of Tc-Eu complex when urea hydrogen peroxide is added to the aqueous solution.
Nuclear energy plays an important role in electricity generation, producing 16% of the world's electricity at the beginning of 1999. It has proven to be safe, reliable, economical and has only a minimal impact on the environment. Most of the world's energy consumption, however, is in the form of heat. The market potential for nuclear heat was recognized early. Some of the first reactors were used for heat supply, e.g. Calder Hall (United Kingdom), Obninsk (Russian Federation), and Agesta (Sweden). Now, over 60 reactors are supplying heat for district heating, industrial processes and seawater desalination. But the nuclear option could be better deployed if it would provide a larger share of the heat market. In particular, seawater desalination using nuclear heat is of increasing interest to some IAEA Member States. In consideration of the ...
The gross calorific value (H{sub o}) is the amount of heat which is generated by total combustion of a type of fuel. It also includes that part of heat which is generated by steam from evaporated water contained in heating gas. In conventional heating boilers, this heat portion is not being utilized at all. To utilize the gross calorific value, it is necessary to extract from the exhaust gas the evaporation heat bound in steam and to return this to the heating system. This means that the exhaust gas has to be chilled by the return water of the heating system and condensed in suitable heatexchangers to well below the dew point. (orig.) [Deutsch] Waermelieferanten im Bereich der Nahwaermeversorgung koennen durch die Anwendung verfuegbarer und bewaehrter Brennwerttechnik ihre ...
Indirect evaporative air coolers that use air-to-air plate-type heatexchangers show good promise (compared with compression air-conditioning systems) of extending the energy savings from arid, low-humidity areas to more widespread climatic conditions. However, no systematic experiment had been done concerning the effect of the wettability of aluminum plates on the effectiveness of the indirect evaporative cooling system. In this study, a testing apparatus was built where only one secondary channel and two primary channels were used so that different surfaces could be easily tested to determine the system`s effectiveness and the heat transfer coefficient. The advantage of this experimental apparatus is that plates of the heatexchanger can be easily changed in the test section instead of fabricating a complete heatexchanger for each test. A ...
We have measured K-edge X-ray absorption spectra of argon in sputtered aluminum films at a synchrotron radiation facility (the Photon Factory). We found that the energy and shape of white line change when the film is annealed at 500 C and the spectrum becomes resembling that of argon implanted in silicon. From the analyses of the X-ray absorption spectra and TEM observation we concluded that argon exists as very small atom clusters with a diameter less than 1 nm or exist as isolated atoms in the as-sputtered aluminum film, and that the size of the clusters become as big as 10 nm diameter when the film is heated. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)
Theoretical investigations on the phase change materials (PCMs) used as the heat storage media for box-type solar cookers have been conducted in this study. The selected PCMs are magnesium nitrate hexahydrate, stearic acid, acetamide, acetanilide and erythritol. For a two-dimensional simulation model based on the enthalpy approach, calculations have been made for the melt fraction with conduction only. Different materials such as glass, stainless steel, tin, aluminum mixed, aluminum and copper are used as the heatexchanger container materials in the numerical calculations. The large value of thermal conductivity of heatexchanger container material did not make a significant contribution on the melt fraction except for at very low thermal conductivities. Based on the theoretical results, stearic acid and acetamide are found to be good compatibility with latent ...
The testing performed during the last phase of the geothermal direct contact heatexchanger program utilizing the 500 kW pilot plant provided more insight into the capabilities and limits of the direct contact approach and showed that more work needs to be done to understand the inner workings of a large direct contact heatexchanger if they are to be modeled analytically. Testing of the column demonstrated that the performance was excellent and that the sizing criteria is conservative. The system operated smoothly and was readily controlled over a wide range of operating conditions. Performance evaluation showed pinch differentials of 4/sup 0/F or less and better than predicted heat transfer capability. Testing during this final phase was directed towards establishing the limits of the column to transfer heat. The working column height was shortened ...
A geothermal heat pump-assisted heating system is introduced into Changchun City and a survey is conducted to determine if the system may be popularized in this extremely cold region located in the northeastern part of China. In concrete terms, the hot water that circulates through the office building of Changchun Ground Heat Development Co., Ltd., is switched to hot water prepared by a geothermal heat pump. The test continued from December 2000 to March 2001. It is then concluded that heating by geothermal heat pumps will be fully serviceable to Changchun City. Implemented are (1) the shift from the coal fired boiler system to a geothermal heat pump system comprising 16 subterranean heatexchangers for the heating of the office building which is approximately 1000 m{sup 2} ...
A self contained continuous power generation system as described at INTELEC 1979, was successfully commissioned and put into service in a major communications centre at Cardiff in Wales. The objective was to provide all telecommunications equipment and electrical building engineering services from a dual fuel enginegenerating plant, and to recover waste heat energy to heat or cool the building. The plant, which is fully automatic, comprises five 1300kW engines using natural gas or diesel oil, and associated waste heat boiler and chiller systems. This paper reviews the functioning of the plant during its first three years of operation.
Heatexchange during laminar flow is studied at the fracture scale on the basis of the Stokes equation. We used a synthetic aperture model (a self-affine model) that has been shown to be a realistic geometrical description of the fracture morphology. We developed a numerical modelling using a finite difference scheme of the hydrodynamic flow and its coupling with an advection/conduction description of the fluid heat. As a first step, temperature within the surrounding rock is supposed to be constant. Influence of the fracture roughness on the heat flux through the wall, is estimated and a thermalization length is shown to emerge. Implications for the Soultz-sous-For\\^{e}ts geothermal project are discussed.
Heat transfer experiments were performed in the post-CHF two-phase flow regime in a vertical tube. The tube inside diameter was 7.75 mm, and the boiling fluid was R-113. The experiments were performed at steady state by means of liquid heating of the test tube. Wall superheats were maintained below 70 C for heatexchanger/steam generator application. The mass flux range of the data was 379-816 kg m{sup -2} s{sup -1}. The use of R-113 significantly extended the property range of the existing low wall-superheat data base. Experimental data are presented in tabular as well as graphical form, and the results were used with low wall-superheat data from other fluids to add generality to a predictive heat transfer correlation. (orig.)
Results of calculational investigations into circulation of water and steam-and-water mixture in the PGV-1000 steam generator heatexchanger bundle used at NPPs with the WWER-1000 reactors, are considered. Model of water circulation in horizontal steam generator with submerged heating surface under conditions of steam generation irregularity along the heat transfer tubes is made. On the basis of the obtained data the assumption is made about water essential overflows from the hot collector zone into the cold one. Overflow rate over the upper line of the heat transfer tubes may constitute 0.7 m/s. The conclusion is made about the necessity to set up the vertical barrier which divides hot and cold sections of heat transfer tubes and helps to avoid water transverse overflows.
The Gas Research Institute established the Gas Appliance Technology Center (GATC) in 1982 to develop improved gas appliances. Between 1986 and 1992, the scope of GATC activities at Battelle included technology transfer and overall industry support, residential appliances, commercial appliances, and residential space conditioning. The following tasks are representative of the GATC activities described in the report; gas burner technology, appliance venting, emissions, water heating, range/oven technology, self-powered appliances, commercial cooktop burners, reconstituting ovens, appliance reliability improvement, combination space-heating/water-heating systems, condensing heatexchangers, corrosion testing, and space heating technology. The report includes references to available sources for further reading.
The major goal of this continuation project is to advance the utilization of heat transfer enhancement techniques in commercial heatexchange equipment. Thirteen heat transfer enhancement techniques have been identified as having potential for improving heat transfer coefficients in full-scale industrial equipment. The following tasks are part of this project, which was originally planned for three years: (1) expansion of technology information base; (2) evaluation of performance of enhanced surfaces and inserts; (3) correlation of data for spirally fluted surfaces; (4) study of structured surfaces in pool boiling; and (5) study of structured surface in spray film evaporation.
An approximate solution was proposed in which a sensitivity analysis by the storage and release of heat was performed for the subject issues and in which an operating method was thereby determined for the equipment constituting the system by means of a linear programming. Accordingly, a heat storage type energy supply system for a district cooling and heating was taken up as a concrete object to be examined. This system consisted of a gas turbine generator, initial power receiving equipment, gas boiler, electric heat pump for ice heat storage, cooling tower, heatexchanger, steam absorbing refrigerating machine, ice heat storage tank, cold and warm water heat storage tank, etc. As a result of comparison between the proposed method and the resolving method, the former showed -0.92 to 2.58% in the ...
Recent developments in heat pump technology have made geothermal-based heatexchange systems particularly well-suited for the heating and cooling needs of buildings even in cold climates. The principles of geothermally-coupled heat pump heating and cooling systems were presented. Results of an in-situ study conducted by Hydro-Quebec on the efficiency of the geothermal heat pump system installed at the Saint-Hyacinthe professional school were summarized. This investigation was meant to be a case study of the applicability of these new technologies to the needs of the Quebec market. After the first year of service, the Saint-Hyacinthe system clearly demonstrated its cost effectiveness over conventional systems. It was predicted that geothermal heat pump systems will gain in popularity in Quebec because they can fully meet ...
High-performance heat transfer augmentation methods applicable in the forced convection field of heatexchangers include a method which requires no external drive means, such as the insertion of a turbulence augmentation object into the flow passage and the use of a wave-shaped flow passage, but disturbs the main stream of flow to raise the heat transportation effect thereby to augment heat transfer in the flow passage. The heat transfer characteristics and thermal performance ratio achieved when sinusoidal-shape plates are inserted instead of augmentation objects, such as cylinders, with a high shape-induced resistance were studied. As a result, the relationship between the resistance coefficient, average Nusselt number, heat transfer coefficient, and pitch was clarified. It has been revealed that the use of eddies with a large gap flow and ...
Two types of evacuated tube solar collectors have been operated in space heating, cooling and domestic hot water heating systems in Colorado State University Solar House I. An experimental collector from Corning Glass Works supplied heat to the system from January 1977 through February 1978, and an experimental collector from Philips Research Laboratory, Aachen, which is currently in use, has been operating since August 1978. A flat absorber plate inside a single-walled glass tube is used in the Corning design, whereas heat is conducted through a single glass wall to an external heatexchanger plate in the Philips collector. In comparison with conventional flat-plate collectors, both types show reduced heat losses and improved efficiency. For space heating and hot water supply in winter, the solar delivery efficiency of ...
An attempt is made to augment the heat transfer efficiency by means of inserting an oscillating thin plate into a tube of the shell and tube heatexchanger. However, the heat transfer augmenting mechanism has not been fully explained. To elucidate this heat transfer augmenting mechanism, an investigation was given on the heat transfer characteristics of a tube inlet at its preliminary run area when a double-hinged oscillating thin plate is inserted in the inlet. As a result of the experiment, the heat transfer augmentation in the tube as a result of inserting the double-hinged oscillating thin plate was found effective when the preliminary inlet run area is treated as the object. However, in comparison of the effect with the heat transfer in a fully developed turbulent region, it was {eta}- 1. The result thus obtained ...
The exchange charge model (ECM) of crystal field is utilized to provide the theoretical explanation of the ground state absorption and the excited state absorption observed for the octahedrally coordinated Ni{sup 2+} ions in the spinel MgAl{sub 2}O{sub 4}. The ECM enables modeling of the crystal field parameters (CFPs) for the impurity ions based on the crystal structure data of the host lattice. To ensure the reliability of the CFPs, the convergence of the CFP values with the increasing number of the coordination spheres taken into account in the ECM calculations is considered. The trigonal CFPs B{sub 2}{sup 0},B{sub 4}{sup 0}andB{sub 4}{sup -3} determined by the ECM, together with the appropriate Racah parameters B and C, serve as input to two crystal field analysis computer packages, which compute the energy level schemes within the whole 3d{sup 8} configuration. The cubic approximation utilizing only one CFP Dq is also ...
A solar energy collection and conversion system is disclosed in which a cassegrain mirror system is rotated about a diurnal axis, which axis is adjusted for seasonal variations in the incidence of the sun's rays on the earth's surface. A black body absorption cavity filled with translucent or transparent fluid material is used for direct absorption of the sun's rays. The incident solar energy is absorbed directly by the fluid medium. The fluid within the cavity may be maintained under extremely high pressures and temperatures in order to utilize this fluid as a heat storage medium. Such heat storage is facilitated by apparatus which permits a change in the volume of the reflective cavity in response to the temperature or pressure of the fluid within the cavity.
The purpose of the invention is to improve a radiation receiver, consisting of a hollow body with an opening for the entry of radiation and a ceramic absorber situated in the hollow body, which absorbs the radiation energy entering through the opening, and emits it as thermal radiation to a heat medium, so that a higher efficiency can be achieved. According to the invention, the problem is solved by the fact that the absorber consists of ceramic material on the side towards the solar radiation, which has a low emission value and a high absorption value, and that the side of the absorber towards the heat medium has ceramic material of high emission value and low absorption value. This ensures that reradiation is prevented near the opening of the hollow body, and that the solar energy entering is largely absorbed in the hollow body.
The paper presents a procedure for the calculation of an absorption-refrigeration plant that uses an LiBr/ZnBr{sub 2}/CH{sub 3}OH solution and is driven throughout the year by heat received from a solar pond. The calculations for the solar pond are based on a finite-difference solution of the transient heat conduction differential equation during the year, and the operation of the refrigeration unit is simulated by the use of functions describing the thermodynamic behaviour of the working medium. On the basis of the procedure devised, correlations and nomographs are developed that describe the seasonally optimum operation of the proposed composite system. The nomographs may be employed for a first estimation in the design of such systems. (Author).
The objective of this work is to improve the process for CO{sub 2} capture by alkanolamine absorption/stripping by developing an alternative solvent, aqueous K{sub 2}CO{sub 3} promoted by piperazine. Thermodynamic modeling predicts that the heat of desorption of CO{sub 2} from 5m K+/2.5 PZ from 85 kJ/mole at 40 C to 30 kJ/mole at 120 C. Mass transfer modeling of this solvent suggests that carbonate and general salt concentration play a major role in catalyzing the rate of reaction of CO{sub 2} with piperazine. Stripper modeling suggests that with the multipressure stripper, the energy consumption with a generic solvent decreases by 15% as the heat of desorption is decreased from 23.8 to 18.5 kcal/gmol. A second pilot plant campaign with 5m K+/2.5 PZ was successfully completed.
The objective of this work is to improve the process for CO{sub 2} capture by alkanolamine absorption/stripping by developing an alternative solvent, aqueous K{sub 2}CO{sub 3} promoted by piperazine. Stripper modeling suggests the energy requirement with a simple stripper will be about the same for 5 m K{sup +}/2.5 m PZ and 7 m MEA. Modeling with a generic solvent shows that the optimum heat of CO{sub 2} desorption to minimize heat duty lies between 15 and 25 kcal/gmol. On-line pH and density measurements are effective indicators of loading and total alkalinity for the K+/PZ solvent. The baseline pilot plant campaign with 30% MEA has been started.
The two-phase heat-transfer and pressure-drop characteristics of offset-strip-fin heat-exchanger geometries are examined using both experimental and analytical modeling techniques. Newly-obtained boiling-flow heat-transfer data are presented for two large-scale offset fin geometries at low-to-moderate wall-superheat conditions. Data for which nucleate boiling appeared to be completely suppressed were analyzed together with similar results for other offset fin surfaces to study the effects of channel dimensions on the convective evaporation component of the local heat transfer coefficient. Although these data were found to be well correlated in terms of modified forms of the F and Martinelli parameters used in previous studies of round-tube flows, a single F-factor correlation valid for all combinations of fin and channel dimensions did not appear to exist. The two-phase pressure-drop characteristics of ...
The service conditions for high-temperature heat-exchangers with helium coolant of HTGRs and requirements imposed on materials for their production are discussed. The choice of nickel-base alloys with solid-solution hardening for long-term service at high temperatures is grounded. Results of study on properties and structure of types Ni-25Cr-5W-5Mo and Ni-20Cr-20W alloy in the temperature range of 900 deg. - 1,000 deg. C are given. The ageing of Ni-25Cr-5W-5Mo alloy at 900 deg. - 950 deg. C results in decreased corrosion-mechanical properties and is caused by the change of structural metal stability. Alloy with 20% tungsten retains a high stability of both structure and properties after prolonged exposure in helium at above temperatures. The alloy has also increased resistance to delayed fracture and low-cycle fatigue at high temperatures. The developed alloy of type Ni-20Cr-20W with microalloying is recommended for production of tubes for HTGR high-temperature ...
Heatexchangers for high and ultrahigh temperatures are a need and a precondition to realise high efficient fossil fired power plants based on the so-called Externally Fired Combined Cycle (EFCC) or the Indirect Fired Gas Turbines (IFGT). The main target of both processes is to increase the thermal efficiency of existing power plants by approximately 25% resulting in the same decrease in fuel consumption and, therefore, in the same reduction of CO{sub 2} formation. The main activities of the MPA University of Stuttgart in this project is focused on the characterisation and qualification of the structural material of the ultrahigh temperature heatexchanger (UHTHE) necessary in the above mentioned processes. The influence of the temperature and load on the material behaviour have been analysed by means of tensile tests and creep tests. The effectiveness of different coating systems and the interaction ...
A mathematical model is described for determining the level profile along the length of heatexchange tubes in a horizontal steam generator, and for determining the conditions in the steam cushion under the perforated sheet. The water level area is divided in the model into 36 partial elements; for analysis of the conditions under the level, the steam-water space is divided into four areas. The results of the calculations were compared with measurement results for the steam generator rated values. Very good agreement was found. The results show that, among others, the supply water distribution very much affects the conditions in the area of the steam cushion and of the bubble vacuum. Also, the average steam load of the inner bundle tubes is significantly higher than that of the outer bundles. It was also shown that permanent steam generator operation with exposed top tube rows may occur even in some permissible operating conditions. This is ...
The deep borehole heatexchanger (BHE) of Weggis is operational since 1994. During the years 1995 to 2000 the BHE has produced for both, direct heating and as a source for the heat pumps, a yearly amount of heat of 220 MWh. The share of direct heating has been more than 60%. The global average power delivered to all consumers has been about 100 kW. This has yielded to a mean source temperature out of the deep BHE of 40.5 {sup o}C and to a mean return temperature of 33.3 {sup o}C. During the years 2000 and 2001 three additional multi-family dwellings have been connected as heat consumers to the BHE. The amount of delivered heat has nearly been doubled (from 220 to 440 MWh per year) as well as the nominal load. This has induced a small reduction of the delivery temperature and a significant reduction of the return ...
Flow-induced vibration is an important concern to the designers of heatexchangers subjected to high flows of gases or liquids. Two-phase cross-flow occurs in industrial heatexchangers, such as nuclear steam generators, condensers, and boilers, etc. Under certain flow regimes and fluid velocities, the fluid forces result in tube vibration and damage due to fretting and fatigue. Prediction of these forces requires an understanding of the flow regimes found in heatexchanger tube bundles. Excessive vibrations under normal operating conditions can lead to tube failure. Relatively little information exists on two-phase vibration. This is not surprising as single-phase flow induced vibration; a simpler topic is not yet fully understood. Vibration in two-phase is much more complex because it depends upon two-phase flow regime, i.e. characteristics of two-phase ...
A cooling system was developed which could be used even in such areas where the maximum and minimum temperatures of a day might differ widely. The system features in that a latent heat storage unit is connected to the natural circulation cooling unit consisting of 2 heatexchangers where condensed gas (refrigerant) which performs gas-liquid change has been sealed, enabling to cool objects night and day without the requirement for any power source. Electronic equipment was installed in an insulated shelter. Lauric acid and refrigerant R-22 were used as the latent heat storage medium and the heat transport medium respectively. Natural convection heat transfer performance of the outside surfaces of the condenser and the evaporator and the transient behavior of the system during the melting and solidification periods of the latent heat storage ...
Until a decade ago, only the differential bobbin type eddy current probe was considered necessary for reliable heatexchanger tube inspection. The introduction of different tube materials, manufacturing processes and a variety of service induced failures has greatly increased the demands of eddy current testing. Optimized probe designs enhanced by improved instrumentation can help satisfy some of these demands. Some of the more difficult inspection problems are detection of circumferential cracks, fretting wear under non-ferromagnetic support plates and shallow internal defects. Reliable detection and sizing of such defects is often made more difficult by the fact they frequently occur in defect prone regions such as under tubesheets or support plates and in transition regions of finned tubes. Probe designs effective in overcoming these difficulties exist. This paper describes a number of such probes and their performance.
DBEs (Design Basis Event) of KALIMER-600 (Korea Advanced Liquid Metal Reactor) were analyzed in one dimension by KAERI (Korea Atomic Energy Research Institute). KALIMER-600 is the pool type SFR (Sodium cooled Fast Reactor), thereby the sodium of primary system is prohibited movement to out of a reactor vessel. There are many contacting and including compositions in the sodium hot pool, such as IHX (Intermediate HeateXchanger), DHX (Decay HeateXchanger), Pump, UIS (Upper Internal Structure), and core. Moreover, the complex phenomena are occurred in sodium hot pool during steady and transient states. Therefore, the one dimensional analysis is modified to the multi-dimensional analysis through modification of sodium hot pool from one to three dimensions
The steam generator inspection and maintenance device has an articulated arm formed at least by two rigid segments connected by a pivot and two plates on the ends of the arms by articulated joints which enable them to rotate about two orthogonal axis. One of the axis is parralel to the axis of the pivot between the arm sections while the other is perpendicular to the surface of the corresponding plate. Each of the plates carries coupling elements which are able to engage with the perforations of the heatexchanger tube plates and also a support for a maintenance tool.
This paper reports that fluidelastic instability is the most important vibration excitation mechanism for heatexchanger tube bundles subjected to cross-flow. Most of the available data on this topic have been reviewed from the perspective of the designer. Uniform definitions of critical flow velocity for instability, damping, natural frequency and hydrodynamic mass were used. Nearly 300 data points were assembled. The authors found that only data from experiments where all tubes are free to vibrate are valid form a design point of view. In liquids, fluid damping is important and should be considered in the formulation of fluidelastic instability. From a practical design point of view, we conclude that fluidelastic instability may be expressed simply in term of dimensionless flow velocity and dimensionless mass-damping. There is no advantage in considering more sophisticated models at this time. Practical design guidelines are discussed.
An energy saving self-powered industrial dehumidifier for use in a building having a tap water conduit leading from a source of supply to utilization points is described comprising: a dehumidifying apparatus positioned in a stream of air to be dehumidified in the building. The dehumidifying apparatus comprising conduit means for diverting at least a portion of a relatively continuously moving stream of tap water from the tap water conduit through a heatexchanger positioned in a stream of air and returning the diverted portion to the tap water stream upstream of the utilization points. Water vapor in the stream of air will condense onto the heatexchanger when the tap water has a temperature below a dew point temperature of the air stream, thereby dehumidifying the air stream.
The need to increase efficiency of volumetric receivers for use in solar power plants by reducing reradiation losses and increasing the ``volumetric effect`` has promoted the idea of a receiver with tapered ducts. These seems to be very promising since higher efficiency and considerable saving of material can be achieved, as compared to conventional receivers perforated with ducts of constant cross-section. A finite element program is being developed to calculate stationary heat transfer in the tapered ducts by free and forced convection in the gas flow, conduction in walls and in the gas, and solar and thermal radiation. Gas and wall temperatures are considered to be varying only in the flow direction. In order to perform the highly nonlinear calculations of radiative exchange, the exact knowledge of the view factors is necessary. The aim of the present work is to evaluate analytically the view factors in tapered ducts.
The performance of binary geothermal power plants can be improved through the proper choice of a working fluid, and optimization of component designs and operating conditions. This paper reviews the investigations at the Idaho National Engineering Laboratory (INEL) which are examining binary cycle performance improvements: for moderate temperature (350 to 400 F) resources with emphasis on how the improvements may be integrated into design of binary cycles. These investigations are examining performance improvements resulting from the supercritical vaporization of mixed hydrocarbon working fluids and achieving countercurrent integral condensation with these fluids, as well as the modification of the turbine inlet state points to achieve supersaturated turbine vapor expansions. For resources where the brine outlet temperature is restricted, the use of turbine exhaust recuperators is examined. The baseline plant used to determine improvements in plant performance (characterized by the ...
A one-dimensional thermal model is derived to describe the temperature field around a vertical borehole heatexchanger (BHEx) for a geothermal heat pump. The inlet and outlet pipe flows are modeled as one, and an effective heat capacity is added to model the heat storage in the fluid and pipes. Parameter estimation techniques are then used to estimate various parameters associated with the model, including the thermal conductivity of the soil and of the grout which fills the borehole and surrounds the u-tube. The model is validated using test data from an experimental rig containing sand with known thermal conductivity. The estimates of the sand thermal conductivity derived from the model are found to be in good agreement with independent measurements.
A one-dimensional thermal model is derived to describe the temperature field around a vertical borehole heatexchanger (BHEX) for a geothermal heat pump. The inlet and outlet pipe flows are modeled as one, and an effective heat capacity is added to model the heat storage in the fluid and pipes. Parameter estimation techniques are then used to estimate various parameters associated with the model, including the thermal conductivity of the soil and the grout that fills the borehole and surrounds the U-tube. The model is validated using test data from an experimental rig containing sand with known thermal conductivity. The estimates of the sand's thermal conductivity derived from the model are found to be in good agreement with independent measurements.
Symplectic integrators designed for simulating soft matter at constant temperature and constant pressure (or constant surface tension) are presented. In addition to the well-known merits of symplectic integrators, such as long time stability, these methods allow the estimation of thermal heat production/absorption and thus entropy differences through a simple function of the time scaling factor ?. The relative entropy estimation around crystal-liquid phase transition is given for systems with soft core repulsive potential.
Every day we are witnesses of constantly rapid increase of consumption of Electric energy in R. of Macedonia as so as in the other countries in all the world. This rapid increase of consumption of Electric energy independent of a lot of electrical units, which are applying in human life like: homes, administration and publication objects, as well as in industry. All of this conditions make us to thinking how is possible more rational consumption of electric energy in all areas in human life. One of the possible manners to reduce the consumption of electrical energy for heating and cooling is to use geothermal heat pumps. In this paper will be proposed geothermal heat pump, which is going to use the heat of earth by vertical and horizontal cupper pipe heatexchanger with data from-GHP (Geothermal Heat Pump) NORDIC, factory in Canada. Also, it ...
A unified model is presented for a class of combined energy systems, in which the systems mainly consist of a heat engine, a combustor and a counter-flow heatexchanger and the heat engine in the systems may have different thermodynamic cycle modes such as the Brayton cycle, Carnot cycle, Stirling cycle, Ericsson cycle, and so on. Not only the irreversibilities of the heat leak and finite-rate heat transfer but also the different cycle modes of the heat engine are considered in the model. On the basis of Newton's law, expressions for the overall efficiency and power output of the combined energy system with an irreversible Brayton cycle are derived. The maximum overall efficiency and power output and other relevant parameters are calculated. The general characteristic curves of the system are presented for some given parameters. ...
The integration of a gas turbine into a new type of coal-fired combined cycle power plant necessitates a multiplicity of far-reaching changes compared with a normal design. The extremely high pre-heating temperature of the air emanating from the heatexchanger of the fluidized bed for the gas turbine combustion chamber has necessitated extensive development work and associated combustion trials. It was possible for these results to influence the design of the burners whereas the manufacture of other components which was on the critical path was already far advanced.
The performance of a 6 kW proton exchange membrane (PEM) electrolyzer was modeled using a semiempirical equation. Total cell voltage was represented as a sum of the Nernst voltage, activation overpotential and ohmic overpotential. A temperature and pressure dependent Nernst potential, derived from thermodynamic principles, was used to model the 20 cell PEM electrolyzer stack. The importance of including the temperature dependence of various model components is clearly demonstrated. The reversible potential without the pressure effect decreases with increasing temperature in a linear fashion. The exchange current densities at both the electrodes and the membrane conductivity were the coefficients of the semiempirical equation. An experimental system designed around a 6 kW PEM electrolyzer was used to obtain the current-voltage characteristics at different stack temperatures. A nonlinear curve fitting method was employed to determine the equation ...
Petropavlovsk-Kamchatky (P-K) city in Kamchatka, Russia is operating hot-water district heating using heavy oil boilers and waste hot water of thermal power plants as heat sources. Feasibility study was made on district heating using natural geothermal hot water and/or geothermal heat pump systems as heat sources of hot water supply for reduction of greenhouse effect gas emission. Among 3 areas including geothermal hot water, use of hot water in K area was impossible because of lower temperature and less spring water. Use of hot water in P and UP areas was impossible as primary hot water because of temperature drop to 64 degrees C during hot water supply toward P-K city. The building heating operation test was carried out using the geothermal heat pump system installed in a newly drilled heat ...
This paper dealt with the identification of possible damaging mechanism of the collector of the WWER 440 steam generator, cracking of primary collectors, corrosion damage of the protective coat of the primary collector circumferential weld, cracking of breathing space in the region of blinding effect by corrosion and strain, leaking of disassembling joint of the primary collector lid and with the integrity of heatexchanging tubes.
A growth model of pitting corrosion of carbon steel in cooling water systems was developed on microscopic observations of pits and electrochemical studies. Results of pitting corrosion measurements in laboratory and field conditions with the model, using a newly developed electrochemical device, are discussed. For an actual heatexchanger up to a year operation, the values of pitting depth estimated were in good agreement with the measured values.
The chain of eddy current probes and a film cassette probe, which responds to radiation from a radio-active source in one of the heatexchanger pipes is examined. The probes are moved by nylon pipes on both ends of the chain through the pipe to be examined. The nylon pipes are bent off load. In this way the probes on the chain will adjust near to the plane of bending of the pipes to be tested.
The largest solar heating and cooling system undertaken to date is now operating at the George A. Towns Elementary School in Atlanta, Georgia. It is expected to provide more than 60 percent of the building's heating and cooling requirements, using commercially available components and techniques. The Towns project is a United States Energy Research and Development Administration-sponsored experiment. The principal components of the solar heating and cooling system designed for the school--the solar collector array, the existing gas-fired boiler, the absorption chiller, and hot and cold water underground tanks to provide thermal storage--are described. To derive maximum benefit from the experiment, the system is fully instrumented for accurate measurement of performance. Environmental data, including insolation and ambient temperture, humidity, and wind conditions will be recorded. The inlet ...
Products having balanced melting point and decomposition temperature have been developed by employing nylon 6T fundamental molecular structure and selected copolymer components, Arlen being one of the products. It has heat resistance as good as that of super-engineering plastics, low water absorption, and excellent cost-performance which can be used for normal injection molding machines. The unit price per kilogram is low when its high heat resistance is taken into consideration. The coefficient of water absorption is as low as about 1/3 of that of nylon 66, and it can be considered to be a low water absorbing amide. The molding temperature is from 320[degree]C to 350[degree]C, the decomposition temperature is 395[degree]C at 2% weight decreasing temperature, and normal injection molding can be employed. It has excellent soldering resistance, high temperature rigidity, dimensional stability, water ...
Microwaves can produce sensations of warmth and sound in humans. In other species, they also can serve as cues, they may be avoided, and they can disrupt ongoing behavior. These actions appear to be due to heat produced by energy absorption. The rate of absorption depends on the microwave parameters and the electrical and geometric properties of the subject. We therefore, cannot predict the human response to microwaves based on data from other animals without appropriate scaling considerations. At low levels of exposure, microwaves can produce changes in behavior without large, or even measureable, changes in body temperature. Thermoregulatory behavior may respond to those low levels of heat, and thereby affect other behavior occurring concurrently. There are no data that demonstrate that behavioral effects of microwaves depend on any mechanism other than reactions to heat. Our ...
In this paper, the unsteady MHD free convection heat and mass transfer of viscous fluid flowing through a Darcian porous regime adjacent to a moving vertical semi-infinite plate under Soret and Dufour effect have been examined. Viscous dissipation effects are included in the energy equation. A uniform magnetic field is applied transversely to the direction of the flow. The differential equations governing the problem have been transformed by a similarity transformation into a system of non-dimensional differential equations which are solved numerically by element free Galerkin method. The influence of Grashof number (Gr), magnetic parameter (M), heatabsorption parameter (Q), permeability parameter (K), Schmidt number (Sc), Soret number (Sr), and Dufour number (Du) on the velocity, tempera...
In this paper, multilayer oxide nanorods were deposited in the nanopores of anodic aluminum oxide (AAO) via solution infiltration followed by heat treatment. The nanorods have a core-shell structure. First, the shell (nanotube) with the thickness of about 40nm was made of TiO"2 through the hydrolysis of (NH"4)"2TiF"6. Second, silver nanoparticles with the diameter of about 3nm were added into the TiO"2 layer through thermal decomposition of AgNO"3 at elevated temperatures. Then, cylindrical cores (nanorods) of CoO and ZnO with 200nm diameter were prepared, respectively. Scanning electron microscopy (SEM) and transmission electron microscopy (TEM) were used to characterize the structure and composition of the nanorods. UV-vis light absorption measurements in the wavelength range from 350 to...
We report on the magnetic hyperthermia properties of chemically synthesized ferromagnetic 11 and 16 nm Fe(0) nanoparticles of cubic shape displaying the saturation magnetization of bulk iron. The specific absorption rate measured on 16 nm nanocubes is 1690+-160 W/g at 300 kHz and 66 mT. This corresponds to specific losses-per-cycle of 5.6 mJ/g, largely exceeding the ones reported in other systems. A way to quantify the degree of optimization of any system with respect to hyperthermia applications is proposed. Applied here, this method shows that our nanoparticles are not fully optimized, probably due to the strong influence of magnetic interactions on their magnetic response. Once protected from oxidation and further optimized, such nano-objects could constitute efficient magnetic cores for biomedical applications requiring very large heating power.
Tokamaks with sufficiently strong supplementary heating develop non-Maxwellian electron velocity distributions. Because the absorption of electron cyclotron power is proportional to #nabla#_Vf, even small deviations from a Maxwellian distribution can significantly affect power deposition. Following an approach used to study microinstabilities in a plasma with an arbitrary, numerically specified, electron distribution, we have developed a computational module to study electron cyclotron power deposition in plasmas that have distributions motivated by those in actual tokamaks. Also, we compare the deposition results obtained using an energy balance approach with those obtained using a Taylor expansion of the dielectric tensor. We illustrate the limitations of the latter approach.
The objective of this work is to improve the process for CO{sub 2} capture by alkanolamine absorption/stripping by developing an alternative solvent, aqueous K{sub 2}CO{sub 3} promoted by piperazine. CO{sub 2} mass transfer rates are second order in piperazine concentration and increase with ionic strength. Modeling of stripper performance suggests that 5 m K{sup +}/2.5 m PZ will require 25 to 46% less heat than 7 m MEA. The first pilot plant campaign was completed on June 24. The CO{sub 2} penetration through the absorber with 20 feet of Flexipac{trademark} 1Y varied from 0.6 to 16% as the inlet CO{sub 2} varied from 3 to 12% CO{sub 2} and the gas rate varied from 0.5 to 3 kg/m{sup 2}-s.
The helium-cooled HTGR (High Temperature Gas-cooled Reactor) will take an important position in the global energy strategy. It is expected to supply not only electricity but also high quality thermal energy for various industries and local utilities without exhausting any green house effect gas or acid rain gas. The key R and D issue of the HTGR is economical competitiveness, particularly against light water reactors. Due to the poor heat transfer of the single phase helium, the HTGR's volumetric power density is restricted to tenth of corresponding PWR's value so that increasing the power density by improving heat transfer is strongly desired. The standstill can be broken through by adopting gas-solid suspension medium. Its heat transfer performance is quite excellent. Its heat capacity can be increased drastically without excessive pressurization. Although the thermal radiation is a dominant ...
Operation safety and reliability are major guidelines in the design of city-gate units. Conventional natural gas heaters operate by a indirect mechanism, where liquid water is used to transfer heat by natural convection between the combustion chamber and the natural gas coil. In this work, the concept of vapor chamber is evaluated as an indirect gas heater. In a vapor chamber, liquid water is in contact with the heat source, and vaporizes. The vapor condenses in contact with the heat sink. A reduced scale model was built and tested in order to compare these two heating concepts where the combustion chamber was replaced by electrical cartridge heaters. This engineering model can operate either as a conventional heater or as a vapor chamber. The comparison between the concepts was done by inducing a controlled power to the cartridges and by measuring the resulting temperature distributions. In the novel ...
In the development of high performance heat transfer surface on a compact heatexchanger, it was clarified that how reattachment point heat transfer and fluid flow are affected by channel width, at the same time, an evaluation of heat transfer performance and an investigation of optimum channel width were carried out. The channel system used in the experiment is as follows; (1) blow-off type with rectangular section channel, (2) span length of 200 mm, (3) wave length (pitch) of 80 mm, and (4) channel length of 12.5 wave length. The channel Reynolds number was set at about 10/sup 4/ which is relatively higher than the current studies. The results of the experiment were summarized as follows. (1) The channel width H has relevance to the phase difference between the fluid flow in cone portion of main stream and wave shape, the flow patterns are divided roughly into three types. These ...
A brief description is given of the physico-chemical parameters characterized a hot water geothermal reservoir and of its exploitation by means of single or coupled (doublet) wells. The technical aspects of geothermal heat to the users is then discussed, beginning with corrosion of materials caused by seven main agents: oxygen, hydrogen sulphide, carbon dioxide, ammonia, hydrogen, sulphates and chlorides. A brief mention is made of scaling due to calcium carbonate, silica and calcium sulphates. The basic components of a geothermal plant for non-electric uses are then discussed: production pumps, surface pipelines, heatexchangers, heat pumps and reinjection pumps. The advantages and disadvantages of the different equipment and materials used in the geothermal sector are also presented. A list is also given of the criteria used in the energy and economic balance of a geothermal operation. (author). 24 ...
Preliminary studies were preformed to determine whether thermal conductivity of cementitious grouts used to backfill heatexchanger loops for geothermal heat pumps could be improved, thus improving efficiency. Grouts containing selected additives were compares with conventional bentonite and cement grouts. Significant enhancement of grout alumina grit, steel fibers, and silicon carbide increased the thermal conductivity when compared to unfilled, high solids bentonite grouts and conventional cement grouts. Furthermore, the developed grouts retained high thermal conductivity in the dry state, where as conventional bentonite and cement grouts tend to act as insulators if moisture is lost. The cementitious grouts studied can be mixed and placed using conventional grouting equipment.
It is reported that due to the large demand for electricity in Japanese homes and given the fact that the energy consumption rate of air conditioners to the total energy consumption rate in an average home exceeds 20%, an energy saving-type room air conditioner is essential, also for environmental reasons. Japanese customers ranked high running costs as a major drawback of conventional equipment. Toshiba started developing the first generation energy saving air conditioners in 1993. Improvements to the concept were made and the 1995 model offers a heating COP of 4.65 and a cooling COP of 4.3 at rated conditions, an improvement of more than 30% compared to the conventional model. Various component improvements have led to this high performance including the indoor fan design, a DC compressor motor and inverter using digital sampling, advanced (PMV) control technology, and compact heatexchangers. The latest feature is ...
The exchange charge model of crystal field theory has been used to analyze systematically the ground state absorption spectra of octahedrally coordinated Ni{sup 2+} ion in isostructural nickel halide crystals NiCl{sub 2}, NiBr{sub 2}, and NiI{sub 2}. The parameters of the crystal field acting on the Ni{sup 2+} ion are calculated from the available crystal structure data. The obtained energy level schemes are compared with experimental absorption spectra; a good agreement with experimental data is demonstrated. Dependencies of the crystal field invariants and covalence effects on the type of ligands are considered. It is shown numerically that the overlap effects between Ni{sup 2+} ion and ligands increase with an increase of the ligands' atomic number resulting in the following order of the degree of covalence: NiI{sub 2}>NiBr{sub 2}>NiCl{sub 2}.
The exchange charge model of crystal field theory has been used to analyze systematically the ground state absorption spectra of octahedrally coordinated Ni"2"+ ion in isostructural nickel halide crystals NiCl_2, NiBr_2, and NiI_2. The parameters of the crystal field acting on the Ni"2"+ ion are calculated from the available crystal structure data. The obtained energy level schemes are compared with experimental absorption spectra; a good agreement with experimental data is demonstrated. Dependencies of the crystal field invariants and covalence effects on the type of ligands are considered. It is shown numerically that the overlap effects between Ni"2"+ ion and ligands increase with an increase of the ligands' atomic number resulting in the following order of the degree of covalence: NiI_2>NiBr_2>NiCl_2.
In order to discuss effects of lithium iodide (LiI) doping on condensation structure of brown coals during heating, spectral changes were measured by using an in-situ FT-IR. It was found that the LiI doping accelerates weight reduction due to heating, and the doping effect is affected by coal structure. Both of Loy Yang (LY) coal and its LiI doped coal (DLY) had absorption intensity of the FT-IR spectra decreased with rising temperature, and the absorption center belonging to an OH group shows different shifts between the LY and DLY coals. This indicates that the LiI doping has affected the change in hydrogen bonding patterns associated with heating. Both of South Banko (SB) and LY coals had the absorption spectral intensity in the OH group decreased as the weight reduction (conversion) rate increased. Reduction in the OH groups associated with ...
Service water, 100 l each, was collected at an intake of a water treatment plant and at a tap after water was left running for five minutes. The carriers of strontium and cesium were added to water immediately after sampling, and the sample was vigorously stirred and filtered. Then it was passed through a cation exchange column at a rate of 80 ml/min. Strontium and cesium were eluted with hydrochloric acid from the cation exchange column, and separated. After the radiochemical separation, the mounted precipitates were counted for activity using low background beta counters normally for 60 min. Net sample counting rates were corrected for counter efficiency, recovery, self absorption and decay to obtain the content of strontium-90 and cesium-137 radioactivity per sample aliquot. From the results, concentrations of these nuclides in the original sample were calculated. The maximum values obtained were 0.29 pCi/l of Sr-90 in ...
Natural minerals and some industrial wastes are used as low cost sorbents for removal of metal ions from effluent streams. Apatite as natural mineral and red mud as an industrial waste have been tested for their sorption properties with respect to two important fission products "1"3"7Cs and "9"0Sr. Their ion exchanging capacity was tested after every 4 hours till 24 hours. The material gets saturated after 4-8 hours. Hence these materials can be considered for treating in treating LLW before discharge, industrial waste treatment and as backfill or admixture material for shallow land repository. (author)
This work proposes an innovative blend of potassium carbonate (K{sub 2}CO{sub 3}) and piperazine (PZ) as a solvent for CO{sub 2} removal from combustion flue gas in an absorber/stripper. The equilibrium partial pressure and the rate of absorption of CO{sub 2} were measured in a wetted-wall column in 0.0 to 6.2 m K{sup +} and 0.6 to 3.6 m PZ at 25 to 110 C. The equilibrium speciation of the solution was determined by {sup 1}H NMR under similar conditions. A rigorous thermodynamic model, based on electrolyte non-random two-liquid (ENRTL) theory, was developed to represent equilibrium behavior. A rate model was developed to describe the absorption rate by integration of eddy diffusivity theory with complex kinetics. Both models were used to explain behavior in terms of equilibrium constants, activity coefficients, and rate constants. The addition of potassium to the amine increases the concentration of CO{sub 3}{sup 2-}/HCO{sub 3}{sup -} in ...
During the past 15 years, 60 straw-fuelled and 25 wood-fuelled district heating stations were commissioned in Denmark, as well as 6 biomass-fuelled heating power stations. All of these plants are equipped with high-pressure boilers, heatexchangers for district heating, and steam turbines with generators. Today, 5 percent of the total energy consumed is provided by biomass fuels. With the new taxes on carbon dioxide emissions and measures to promote renewable energy sources, a 15 percent share can be expected soon. (orig/SR) [Deutsch] In Daenemark wurden in den letzten 15 Jahren 60 strohbefeuerte und 25 holzbefeuerte Fernwaermewerke in Betrieb genommen. Dazu sind in den letzten Jahren 6 biomassebefeuerte Heizkraftwerke gekommen. Alle Anlagen haben Hochdruckkessel, Waermetauscher fuer Fernwaerme und Dampfturbinen mit Generatoren. Heute werden in Daenemark 15 Prozent des ...
Flow structures and heat transfer at the liquid-liquid interface are investigated experimentally and analytically in the entrance region of a liquid metal-water stratified flow in a horizontal rectangular channel. The two-equation model and the mixing length mode, including a damping turbulent region near the interface, are used to obtain analytical results for pressure drop, position of the interface, and heat transmission coefficients across the interface. Analytical results are compared with experimental results. Conclusions are presented and include the following: (1) vertical position of the interface increases or decreases along the stream according to the fluid flow rate of both fluids, and then approaches a constant value in the fully developed region; (2) pressure drop increases along the stream from the minimum value at the inlet; and (3) heat transmission coefficients across the interface decrease in the entrance ...
A conceptual fusion synfuel production system has been developed with the unique features of: (1) a fusion blanket producing high-temperature (1250"0C) process heat, and (2) the GA sulfur-iodine thermochemical cycle. The system incorporates a two-zone blanket which achieves a tritium breeding ratio of 1.1 while delivering a high fraction (30%) of the fusion heat at high temperatures (1250"0C). The multiple barriers to tritium permeation in the blanket design permit the hydrogen product to meet 10CFR20 regulatory requirements without stringent requirements on the tritium recovery systems. A ceramic heatexchanger, incorporating SiC tubes and headers to contain the process stream and a cooled, Inconel 718 pressure shell to contain the helium, was designed for transferring the heat from the high-temperature coolant to the process. A good heat-line match of the ...
One of the main points for the inherent safety of a pebble bed high temperature reactor (HTR) is to guarantee the safe removal of the after-heat in case of a break-down of all active cooling systems like heat-exchangers or liner-cooling. This will be necessary because it is well known today that graphite pebble bed fuel elements stay intact, if the accident temperature is below 1600 deg. C. Therefore the heat must be taken out of the reactor system by passive, natural law heat-transfer mechanism so that the maximum fuel temperature stays below the specified limit. Today medium-sized HTRs with a power of 750 MW_t_h and more (TGTR-300, HTR 500) reach temperatures of more than 2400 deg. C in small parts of the core in such hypothetical accidents. A possible way to realize the inherent safe heat removal in advanced medium-sized HTRs is to change the form of the core. Instead of ...
During the last two decades, the demand for higher heat transfers in the heatexchangers has kept increasing. These high heat transfer rates can be obtained by using two-phase flows, or heat transfer augmented surfaces, or in some cases, both. Thus, the boiling flows and the associated two-phase flow instabilities have been studied by many investigators. Most of the work in boiling flows has been concentrated on single channel upflow systems or on parallel channel systems with plain heat transfer surfaces. The boiling flow instabilities in multi-channel systems should be covered to a greater extent, studying the effects of various parameters, such as inlet and outlet restriction, mass flow rates, the property variations, heat transfer coefficients, equal and unequal heat inputs on the stability. Also, the mathematical ...
The corrosion resistance of zircaloy is affected by conditions of heat treatment in the manufacturing steps to be formed into a final product as a structural material. In the manufacturing method of the present invention, a Zr alloy controlled to contain Sn: 0.8 to 1.2wt%, Fe: 0.17 to 0.28wt%, Cr: 0.05 to 0.15wt%, Ni: 0.04 to 0.10wt%, Nb: 0.01 to 0.09wt%, oxygen: 1,000 to 1,500ppm and Si, an Si impurity at a concentration of 120ppm or less and balance of Zr is melted into a cast piece, to which #beta# hardening is applied. Then, rolling and annealing treatment are applied so that the total heat input amount to the material: #SIGMA#Ai ranges from 1 x 10"-"1"9 to 1 x 10"-"1"7. With such procedures, a Zr alloy structural material for a reactor core having excellent homogeneous corrosion resistance and hydrogen absorption resistance for a long period of time while having a sufficient strength can be obtained even in a case ...
In the microwave tokamak experiment (MTX) program, we are concentrating on experiments using intense, free-electron laser (FEL) generated microwave pulses. In initial FEL experiments, several diagnostic instruments were operated during injection of microwave pulses with peak powers to 0.2 GW at durations of 10 ns. Fixed and spatially scanning microwave detectors and receivers and a 48-element calorimeter on the inside wall of MTX diagnosed the GW-level FEL microwave pulses. With these diagnostics, linear-wave absorption and efficiencies of transmission through the quasi-optical transport system were studied. In addition, several radially resolved measurements of plasma density, temperature, and emission were made during FEL injection and were used in the analysis of microwave absorption data. A timing system, slaved to the FEL pulse arrival time, is capable of accuracy to a few nanoseconds in order to allow measurement of ...
The most developed systems for the generation of electricity from coal are the Integrated coal Gasification Combined Cycle (IGCC) and the Pressurized Fluidized Bed Combustion (PFBC) system. They both represent state-of-the-art technology and provide electric power at 41-46% LHV efficiency. However, the high level of complexity leads to lower reliability and higher costs. A simpler system, based on a coal-fired steam boiler integrated with a gas turbine, has been proposed. In such a plant, known as the externally fired combined cycle (EFCC), compressed air is heated indirectly in a heatexchanger located in the coal furnace. The hot air is then expanded in a turbine, and the exhaust is passed on to the coal furnace as preheated combustion air. Steam produced in the boiler generates additional power in a steam turbine. The exclusion of coal combustion products from the gas turbine avoids hot gas clean-up and turbine blade ...
In 1994, the United States Department of Energy, the United States electric utilities and the geothermal heat pump (GeoExchange) industry formed a non-profit collaborative effort called the Geothermal Heat Pump Consortium (GHPC). The objectives were the reduction and/or elimination of 1.5 million metric tons of carbon equivalent per year and making geothermal heat pumps a significant part of the Heating Ventilation Air Cooling (HVAC) industry. Federal funding of 35 million dollars over six years was matched by 65 million dollars of private sector funds to attain these objectives and create a self-sustainable GeoExchange market. The major accomplishments of this endeavour, as well as the lessons learned were presented in this paper. The infrastructure was strengthened, first cost was reduced, and awareness of the technology was increased over the past six years ...
The externally fired combined cycle (EFCC) process utilises a high temperature heatexchanger to transfer the heat of a dirty flue gas to a clean working medium. In comparison to other combined cycle concepts, like integrated gasification combined cycle or pressurized pulverized coal combustion, the problems of hot gas cleaning are avoided. The first part of the publication (BWK 5/02) deals with the possible concepts and the efficiency potential of the externally fired combined cycle. The applicability of metallic and ceramic heatexchanger materials are discussed. The second part summarizes the state of the art and presents the basic design of a ceramic heatexchanger. [German] Der extern gefeuerte Gasturbinenprozess arbeitet mit einem Waermeuebertrager, um ein Arbeitsmedium auf Gasturbineneintrittstemperatur zu erhitzen. Im Vergleich zu ...
The externally fired combined cycle (EFCC) process utilises a high temperature heatexchanger to transfer the heat of a dirty flue gas to a clean working medium. In comparison to other combined cycle concepts, like integrated gasification combined cycle or pressurized pulverized coal combustion, the problems of hot gas cleaning are avoided. The first part of the publication deals with the possible concepts and the efficiency potential of the externally fired combined cycle. The applicability of metallic and ceramic heatexchanger materials are discussed. The second part (BWK 6/02) summarizes the state of the art and presents the basic design of a ceramic heatexchanger. (orig.) [German] Der extern gefeuerte Gasturbinenprozess arbeitet mit einem Waermeuebertrager, um ein Arbeitsmedium auf Gasturbineneintrittstemperatur zu erhitzen. Im ...
RADSOLVER is a computer program which calculates the radiation energy transport in cavity type receivers having an arbitrary number of apertures through which collimated beams of solar radiation enter. In contrast to the common assumption of gray (or semi-gray) surfaces used in the modeling of radiation transport, RADSOLVER accounts for the wavelength-dependence of emission, absorption and reflection with a band model of the radiative properties. It is intended that this report serve both as an instruction manual for the use of the RADSOLVER code and a vehicle for presenting the underlying theory. Illustrative examples along with input and output are presented.
With a computerized curve fitting method the trapping parameters of TLD-100 chips were calculated after #alpha#-, #beta#- and #gamma#-irradiation. The absorption of radiation produces an additional glow peak at 250 deg C, and the dominant one arises at 280 deg C. After the analysis of the glow curves only a little LET-dependence of the trap depths and that of the half widths was detected. The charge densities after irradiation before heating of the taps responsible for the high temperature glow peaks (T>240 deg C) show a LET-dependence. (author).
The ElectroScan environmental scanning electron microscope (ESEM) is one of the most exciting new developments in the field of Electron Microscopy. The ESEM differs from conventional Scanning Electron Microscopes (SEM) by being able to examine materials including liquids and oils in their natural state with no prior sample preparation. Accessory equipment, cooling, heating and manipulating devices allow the manipulation of samples thus making it possible for the first time to image dynamic processes such as wetting, drying, absorption, corrosion, melting, crystallisation, curing and fracturing at high magnification. Papers concerning the historical development of the ESEM are given in a bibliography at the end of this paper. 24 refs., 18 figs.
This article proposes a model for estimating the effect of the overall thermal resistance of the absorber and the coolant on a solar thermal energy system utilizing advanced heat transfer mediums. Two equations can be used to model a dynamic system: one for the maximum conversion efficiency and one to specify the constraint that, in quasi-steady state, the net energy collected must be transferred to the coolant. These two equations define a constrained optimization problem in two variables, the fluid and the absorber temperatures. The results present interesting implications for liquid metal, direct absorption, and solar evaporating systems.
In the present paper, experimental study of forced convection boiling were performed to investigate the post-CHF characteristics of a vertical annular channel with one heated rod and four spacer grids for new refrigerant R-134a. The experiments were conducted under outlet pressure of 11.6, 13, 16 and 20 bar, mass fluxes of 100-600 kg/m{sup 2}s, and inlet temperatures of 25-51 .deg. C. The parametric trend of the post-CHF data was well consistent with previous studies. The two phase flow regime in tube flow occurring downstream of the CHF has been called post-CHF, dispersed flow, liquid-deficient flow, mist flow and film boiling. This regime is characterized by a continuous vapor phase with discrete liquid drops and a non-wetted heated surface. This regime has a considerable importance in the areas of light water reactor(LWR) accident analysis and other film boiling applications. The post-CHF region occurs by design in heat ...
In the present paper, experimental study of forced convection boiling were performed to investigate the post-CHF characteristics of a vertical annular channel with one heated rod and four spacer grids for new refrigerant R-134a. The experiments were conducted under outlet pressure of 11.6, 13, 16 and 20 bar, mass fluxes of 100-600 kg/m2s, and inlet temperatures of 25-51 .deg. C. The parametric trend of the post-CHF data was well consistent with previous studies. The two phase flow regime in tube flow occurring downstream of the CHF has been called post-CHF, dispersed flow, liquid-deficient flow, mist flow and film boiling. This regime is characterized by a continuous vapor phase with discrete liquid drops and a non-wetted heated surface. This regime has a considerable importance in the areas of light water reactor(LWR) accident analysis and other film boiling applications. The post-CHF region occurs by design in heat ...
Tarapur Atomic Power Station unit-4 is first 540 MWe pressurized heavy water reactor. Heavy water is used as the coolant and moderator. With reactor operation tritium is formed by absorption of neutron by Deuterium atoms. Experience in the 220 MWe indicates that tritium is main contributor to the internal dose of radiation workers. Study on Tritium build up in Primary Heat Transport (PHT) and Moderator (MOD) system was carried out at the initial stage of the operation of the unit-3 and 4. This paper brings out tritium activity buildup in the PHT and MOD systems and its comparison with 220 MWe reactors. This paper helps in estimation of the internal dose contribution to the radiation workers at TAPS 3 and 4. (author)
Tarapur Atomic Power Station unit-4 is first 540 MWe pressurized heavy water reactor. Heavy water is used as the coolant and moderator. With reactor operation tritium is formed by absorption of neutron by deuterium atoms. Experience in the 220 MWe indicates that tritium is main contributor to the internal dose of radiation workers. Study on tritium build up in Primary Heat Transport (PHT) and Moderator (MOD) system was carried out at the initial stage of the operation of the unit-4. This paper brings out tritium activity buildup in the PHT and MOD systems and its comparison with 220 MWe reactors. This paper helps in estimation of the internal dose contribution to the radiation workers at TAPS 3 and 4. (author)
A brief summary of the theory and experiments on electron- cyclotron heating and current drive is presented. The general relativistic formulation of wave propagation and linear absorption is considered in some detail. The O-mode and the X-mode for normal and oblique propagation are investigated and illustrated by several examples. The experimental verification of the theory in T-10 and D- III-D is briefly discussed. Quasilinear evolution of the momentum distribution and related applications as, for instance, non linear wave, damping and current drive, are also considered for special cases of wave frequencies, polarization and propagation. In the concluding section we present the general formulation of the wave damping and current drive in the absence of electron trapping for arbitrary values of the wave frequency. (Author) 13 refs.
Carbon dioxide is receiving renewed interest as an efficient and environmentally safe refrigerant in a number of applications, including mobile air conditioning and heat pump systems, and hot water heat pumps. Compact heatexchangers for CO{sub 2} systems are designed with small-diameter tubing. The purpose of this study is therefore to provide a better basis for understanding and predicting heat transfer and pressure drop during flow vaporization of CO{sub 2} in microchannels. The ''unusual'' properties of carbon dioxide give heat transfer and two-phase flow characteristics that are very different from those of conventional refrigerants. Examples of these differences are the much higher pressure, the resulting high vapour density, a very low surface tension, and a low liquid viscosity. High pressure and low surface tension ...
Full text of publication follows: The heat transfer and flow in narrow channels has lots of advantages such as compact structure, high efficiency, design flexibility and so on. So it is widely used in the fields such as the new reactor core plate elements, the once-through stream generator, compact heatexchangers as well as electronic components. In recent years, more strong attentions have been attracted to the thermal-hydraulic characteristics and mechanism of the two-phase flow in narrow channels. As the flow regime characteristics of two-phase flow is fundamental one of them, the research on the two-phase flow regimes and the regime transitions in horizontal rectangular narrow heated channels can provide theoretical foundation and engineering directions to the whole research on the thermal-hydraulic characteristics and mechanism of the two-phase flow in narrow channels. The characteristics of ...
Full text of publication follows: The heat transfer and flow in narrow channels has lots of advantages such as compact structure, high efficiency, design flexibility and so on. So it is widely used in the fields such as the new reactor core plate elements, the once-through stream generator, compact heatexchangers as well as electronic components. In recent years, more strong attentions have been attracted to the thermal-hydraulic characteristics and mechanism of the two-phase flow in narrow channels. As the flow regime characteristics of two-phase flow is fundamental one of them, the research on the two-phase flow regimes and the regime transitions in horizontal rectangular narrow heated channels can provide theoretical foundation and engineering directions to the whole research on the thermal-hydraulic characteristics and mechanism of the two-phase flow in narrow channels. The characteristics of ...
This paper deals with the externally coal-fired combined cycle (EFCC). A process simulation for different configurations of the EFCC-process is carried out as well as an investigation of the effect of the key parameters such as the gas turbine inlet temperature and the compressor intake airflow. The results show a promising potential of the efficiency. One component of this combined gas and steam turbine cycle is a high temperature heatexchanger that has to withstand the extrem chemical and thermal operating conditions. Fibre reinforced ceramics and combinations of them with monolithic ceramics seem to be the most promising materials for this application. A cost estimating of the EFCC-process shows that a competitive operation should be possible. (orig.) [Deutsch] Die Ergebnisse der Prozesssimulationen weisen ein vielversprechendes Wirkungsgradpotential des extern kohlebefeuerten Gasturbinenprozesses auf. Der fuer dieses neue Kraftwerkskonzept ...
In the heatexchangers of power plants, scale deposition may occur, especially at the leading edge of contraction. The growth of scale can lead to an increase in pressure and cause oscillation of the water level. In our previous study, the dependence of flow on contraction geometry was analyzed numerically and empirically. It was shown that the contraction ratio of hydraulic diameter of the flow path contributed greatly to the difference in pressure drop and turbulent kinetic energy at the leading edge of the flow path. In this study, the effect of contraction geometry and flow rate on scale adhesion was studied in AVT chemistry at 270degC using a high-velocity scale-adhesion test loop. The differential pressure and the amount of scale deposited due to scale adhesion at the leading edge of the flow path increased more in a quatrefoil-type flow path than in drill-type flow path. The differential pressure and the amount of scale deposited also ...
Steam generators (SG) are the weak link of nuclear power plants, their service life is shorter than the service life of other NPP components. This paper is dedicated to a statistical analysis of SG damages and failures. Heatexchanging tubes (HET) are the most damaged elements in SG, there are on average 286 plugged or repaired tubes in each operating SG. The usually mechanisms of tube failure are the following: denting, corrosion at tube outside, pitting, fretting, and circular crack propagation. Most of damages are located in the transition zone above a tube plate. This study shows that the factors that are involved in the SG HET fault probability are: - design features of SG and secondary equipment elements (high pressure feed heaters (HPFH), low pressure feed heater (LPFH)), - water chemistry at different points of condensate feed pipe, composition and density of deposits on HET surface, efficiency of mechanical and chemical washing, - the ...
It is one of the most important subjects to estimate the flow-related stability of the heatexchanger tubes. A large scale model steam generator has been developed to verify the stability of the tubes in the Japanese PWR steam generators for the two-phase flow-induced vibration and to accumulate related technical data of thermal-hydraulic and flow-induced vibration of U-bend tube bundle. The model steam generator has 230 U-bend tubes of 46 different radius and 5 columns for each of practical diameter and material, and the anti vibration bars are inserted into each spacing between tube arrays. The freon R123 has been used as the secondary side fluid in stead of water-steam two-phase. In the test, void fraction and interfacial velocities in U-bend and straight tube-bundle are measured with bi-optical probes, and vibration responses of some selected tubes are measured with strain gauges and accelerators. It is verified that the U-bend tubes are ...
CANDU steam generators and heatexchangers have been afflicted with a significant variety of degradation mechanisms. Until recently, detection and characterization of most of the varieties of flaws required usage of several different eddy current techniques. Tubes needed to be scanned multiple times to ensure they were inspected for all possible degradation mechanisms. The time required to deploy so many different types of techniques to inspect the steam generator tubes has had a significant impact on the inspection schedules. The X-Probe was designed with an array of eddy current coils capable of detecting, characterizing and sizing axial, circumferential and volumetric flaws. The X-Probe is a fast-scanning probe with scanning speed equivalent to speeds typically used for simple bobbin coil probes. With its capability of fulfilling most if not all of the functions of the other tube-testing eddy current probes, it can inspect each tube for all ...
CANDU steam generators and heatexchangers have been afflicted with a significant variety of degradation mechanisms. Until recently, detection and characterization of most of the varieties of flaws required usage of several different eddy current techniques. Tubes needed to be scanned multiple times to ensure they were inspected for all possible degradation mechanisms. The time required to deploy so many different types of techniques to inspect the steam generator tubes has had a significant impact on the inspection schedules. The X-Probe was designed with an array of eddy current coils capable of detecting, characterizing and sizing axial, circumferential and volumetric flaws. The X-Probe is a fast-scanning probe with scanning speed equivalent to speeds typically used for simple bobbin coil probes. With its capability of fulfilling most if not all of the functions of the other tube-testing eddy current probes, it can inspect each tube for all ...
To raise the efficiency of the redox method and decrease the amount of radioactive wastes, a possibility of improving the decontamination process for NPP heatexchanger tubes made of stainless steel is studied. In the home practice the redox method of equipment decontamination is carried out as a multi-cycle process. In each cycle the surface is treated first with a permanganate alkaline solution ther with an oxalic acid solution, with a condensate washing-at between the treatments. Using samples cut out of the steam generator pipelines of the first and third power units of the Novovoronezh NPP the effect of the oXalic acid concentration, as well as washout time and conditions on the decontamination factor are studied. On the basis of analysis of the obtained data a conclusion is drawn that using oxalic acid of low concentrations and increasing its concentrations from cycle to cycle maximum decontamination factor values can be obtained at a ...
Two 40 MWe Ocean Thermal Energy Conversion (OTEC) Pilot Plant programs are in the initial phase of development near Kahe Point, Oahu, Hawaii. The two options being examined are: (1) a shelf-seated artificial island, connected via a causeway to Oahu, using stainless steel heatexchangers, with the thermal resource enhanced by effluent from a near-by power plant, ammonia working fluid and biocide (chlorine) cleaning; and (2) a shelf mount tower 1 mile off shore using submerged aluminum heatexchangers, R-22 working fluid, and slurry cleaning with biocide (chlorine) backup. Environmental Technical Requirements are described including: siting criteria; environmental design, and operational criteria; thermal resource evaluation and variability; physical, chemical, and biological data requirements; and regulatory requirements. Due to siting, design, and operational differences the proposed two pilot plant ...
The development of a silicon carbide (SiC) heatexchanger is a critical step in the development of the Externally-Fired Combined Cycle (EFCC) power system. SiC is the only material that provides the necessary combination of resistance to creep, thermal shock, and oxidation. While the SiC structure materials provide the thermomechanical and thermophysical properties needed for an efficient system, the mechanical properties of the SiC tubes are severely degraded through corrosion by the coal combustion products. To obtain the necessary service life of thousands of hours at temperature, a protective coating is needed that is stable with both the SiC tube and the coal combustion products, resists erosion from the particle laden gas stream, is thermal shock resistant, adheres to SiC during repeated thermal shocks (start-up, process upsets, shut-down), and allows the EFCC system to be cost competitive. This demanding set of technical performance and ...
It was to be investigated why inexplicable cracking occurred in plain stainless austenitic steel pipes of heatexchangers in discrete sites of the inner surface exposed to acid even with anodic corrosion protection, and what countermeasures must be taken. The following materials were investigated: X 6 CrNiTi 18 10 and X 6 CrNiMoTi 17 12 2. The influence of mechanical vibrations on passive film formation and destruction was investigated in unconstrained pipes and pipes constrained at one end in conditions of anodic protection at frequencies of 0 to 160 Hz and temperatures of 98 to 130 degrees Centigrade in 98% sulphuric acid. The authors were unable to reconstruct the cracks observed in practical operation in anodically protected heatexchanger pipes of stainless austenitic steel. (orig./MM). 5 refs., 2 tabs., 71 figs.
In relation to coal gasification and combustion under high pressure as highly efficient coal utilization, the effect of total pressure and sintering on the SO2 capture ability of Ca-ion exchanged coal and other desulfurizing agents were studied. In experiment, specimens were filled into a small pressurized reactor to heat them under high-pressure N2 atmosphere. After the completion of combustion reaction of char at 850{degree}C, SO2, CO2 and CO gases were measured at an outlet while flowing SO2/N2. As the experimental result, all of the S content in Ca-ion exchanged coal was not absorbed by Ca content in coal during pyrolysis and combustion, resulting in discharge of 36% of the S content. Since Ca-ion exchanged coal is fast in combustion reaction, most of the S content was desulfurized by coal ash. The ash content yielded from Ca-ion exchanged coal was more excellent in SO2 capture ...
Apparatus for minimizing thermal loss in a windowless, open cavity solar receiver due to airflow at the receiver aperture includes means for deflecting wind away from the cavity opening such that flow stream reattachment occurs away from the receiver aperture to provide a dead air zone at the cavity opening. This prevents turbulent-mixing airflow exchange between ambient air and heated air within the solar receiver. The wind deflector apparatus includes either a passive annular deflection foil at the receiver aperture, or an active device for producing an outwardly projected air jet at the receiver aperture.
The tube bundle arrangement is suitable as reheating section of a steam generator in combination with a gas-cooled reactor. For any high-temperature section with a straightline type tube bundle, there is one inlet and one outlet collecting main; these two are arranged one opposite to the other and diametrically to the tube bundle. There are a number of lines from the inlet collecting main to the outlet collecting main; these lines are arranged axially one on top of the other and run around the tube bundle helically several times. (GL) 891 GL/GL 892 MB.
Standard radiation monitoring has been conducted at Sendai nuclear power station for the purpose of estimation of 'source activity' during refueling outage and evaluation of countermeasures to reduce dose rate. Selected objects of the monitoring are radiation dose rate at maintenance area, radiation field at each equipment and piping, coolant chemistry and plant operation condition. Monitored data indicates that 'source activity' variation can be estimated to some extent using influential factors, and that evaluation of change of loose crud activity, which is presumed to be represented by the dose rate at letdown heatexchanger, is necessary to further explain change in radiation field at main work area. (author).
ABS>A horizontal steam generator design for the SM-2 was lysis to determine the per formance of such a steam generator under steady state operating conditions and during load transients, The configuration for this design is a two- drum unit consisting of a heatexchanger unit and separator drum interconnected by integral riser and downcomer. An analog computer was used to analyze the steam generator behavior Wring load transients. The effect of various design changes on the response of the steam generator to step chages in load was determined. The horizontal steam generator design was compared to the existing vertical steam generator design for weight, size, price, and performance. (auth)
In most industrial processes operating at elevated temperatures, protective oxide layers perform a vital duty in protecting the underlying metallic alloys from process gases. Coal-fired combined cycle power generation systems present a number of process conditions in which the properties of the protective oxide layers are particularly important. This paper discusses two of these particular conditions: (1) `erosion/corrosion` of in-bed heatexchanger tubing and (2) thermal cycling of hot gas path components. For both these situations, the desirable properties of protective scales are outlined. The behaviour of scales in practice are highlighted. 33 refs., 6 figs., 2 tabs.
An isotopic exchange method was used to label lipiodol with [sup 131]I. The labelling efficiency was > 92.5%, and the radiochemical purity of [[sup 131]I]lipiodol was above 98% as determined by ITLC. The influencing factors e.g. the heating temperature, reaction, pH and storage conditions were studied and the optimum conditions were determined. In a pilot study injecting [[sup 131]I]lipiodol for the treatment of hepatoma, about 70% of hepatoma patients had a response to the treatment with a reduction of [alpha]-fetoprotein and decrease of hepatoma sizes. The overall median survival was 9 months (range 2-17 months). (author).
The bibliography contains citations concerning the pitting corrosion of copper and copper alloys, in different media, with some references to methods for protecting against such corrosion. Included are factors contributing to the onset of pitting corrosion. Emphasis is placed on exposure to water, especially in tubing for heatexchangers and water conduits. Many of the citations present studies on exposure to sea water. Some references pertain to the detection of pitting corrosion in installations and the evaluation of the degree of pitting present. (Contains 250 citations and includes a subject term index and title list.)
The bibliography contains citations concerning the pitting corrosion of copper and copper alloys by different media, with some references to methods that protect against such corrosion. Included are factors contributing to the onset of pitting corrosion. Emphasis is placed on exposure to water, especially in heatexchanger tubing and water conduits. Studies are included which examine corrosion in metals containing small amonts of copper where corrosion is attributable to changes in alloying. (Contains a minimum of 158 citations and includes a subject term index and title list.)
Copper alloys are a suitable tubing material for turbine condensers and heatexchangers. Due to problems with corrosions copper alloys increasingly are displaced by high-grade steel and titanium. Blockages and surface formation in the pipes, disturbance of the oxide coating formation, erosion and quality faults with the production are the causes for the corrosion. In the contribution under consideration counter measures are designated for the solution of the problems with corrosions. The application limits for different copper alloys are designated. Recommendations for the optimized operation are given.
Unit one of Daya Bay, China's first nuclear power plant was officially opened in February 1994. The nuclear island has been built by Framatome and is an improved version of the Gravelines 5 and 6, 900MWe Pressurized Water Reactors. Extra seismic protection has been included because of greater earthquake risk. The heatexchanger capacity has also been increased as the sea cooling water can be at 30"oC. The technical specifications and details of the fuel loading are given. The technical assistance, management and training of Chinese personnel are discussed. Two further units may be built if Daya Bay 1 is successful. (UK).
This study deals with the application of wavelet analysis to detection and characterization of defects from eddy-current and ultrasonic testing signals of a low signal-to-noise ratio. Presented in this paper are the methods for processing eddy-current testing signals of heatexchanger tubes of a steam generator in a nuclear power plant. The results of processing eddy-current testing signals of tube test pieces with artificial flaws show that the flaw signals corrupted by noise and/or non-defect signals can be effectively detected and characterized by using the wavelet methods. (author)
The development of high energy (> 150 keV) neutral beams for heating and fueling magnetic fusion devices depends on the ability to produce well-collimated negative ion beams. The double capture charge-exchange technique is a known, scalable method. In order to maximize the overall efficiency of the process and to achieve the desired beam characteristics, it is necessary to examine the optical qualities of the beams as well as the total efficiency of beam production. A combined modeling and experimental study of the angular scattering effects in negative ion formation and loss processes has therefore been undertaken.
Although there is service experience of Alloy 800 as tubing for superheaters in conventional and nuclear (HTR) power stations and in PWR heatexchangers, there is no corresponding service experience in sodium-cooled fast reactor steam generators. However, some limited experimental studies have been made of corrosion behaviour, and of possible structure modifications and effects on mechanical properties which occur during exposure of this material to a high temperature sodium environment, and these are summarised in the paper. It is concluded that further work needs to be done before Alloy 800 can be confidently endorsed for use as tubing in fast reactor steam generators. (author).
The two-fluid model representation for calculations of two-phase flow characteristics in the FBR fuel pin bundles with liquid metal cooling is presented and analysed. Two conservation equations systems of the mass, momentum and energy have been written for each phase. Components accounted the mass-, momentum- and heat transfer throughout the interface occur in the macro-field equations after the averaging procedure realisation. The pattern map and correlations for two-fluid model in vertical liquid metal flows are presented. The description of processes interphase mass- and heatexchange and interphase friction is determined by the two-phase flow regime. The opportunity of the liquid metal two-phase flow regime definition is analysed. (author)
The ORR operated at an average power level of 29.7 MW for 85.3% of the time during this period. The reactor was shut down on fifteen occasions, nine of which were unscheduled. Reactor downtime needed for refueling and checks was normal. The reactor remained available for operation 88.3% of the time. Special tests completed during the quarter included: (1) transfer of LEU fuel elements CLE-202 and NLE-201 from core positions B-9 and B-2 to core positions C-5 and C-6 for continued operation; and (2) calculation of maximum heat flux in LEU elements CLE-201 and NLE-202 in core positions A-2 and A-8. In-service inspections included inspections of ORR decay tank, primary heatexchanger No. 4, and the 24-in. strainer.
A new chemical reactor, the Open Plate Reactor, is being developed by Alfa Laval AB. It combines good mixing with high heat transfer capacity into one operation. With the new concept, highly exothermic reactions can be produced using more concentrated reactants. A nonlinear model of the reactor is derived and a control system is developed. For temperature control a cooling system is designed and experimentally verified, which uses a mid-ranging control structure to increase the operating range of the hydraulic equipment. A Model Predictive Controller is proposed to maximize the conversion under hard input and state constraints. An extended Kalman filter is designed to estimate unmeasured concentrations and parameters. Simulations show that the designed control system gives high conversion ...
Applications, techniques, instrumentation, and interpretation of flow visualization are discussed. Methods of using flow visualization for the examination of combustion in furnaces, heat transfer with heatexchangers, and in fluid engines are explored, along with flow visualization in food processing, steel-casting, and process engineering. Further attention is given to pipe and channel flow, flow separation in laminar flow and around oscillating airfoils, wakes and vortices, supersonic flow and shock waves, and stratified flow and oceanography. The visualization of boundary layers is considered for various conditions, and applications for multiphase flow, rheology, and medical problems are detailed. Oil film, dry-surface coating, chemical, fluorescent, and minituft methods are presented, as well as the use of tracers, optical techniques, strobe lights, lasers, computerized data acquisition, and hot-wire anemometry.
MINC stands for Multiple INteracting continua.'' It is an approximate method for modeling fluid and heat flow in fractured- porous media, developed by Pruess and Narasimhan (1982, 1985) at the Lawrence Berkeley Laboratory. The method is applicable to flow processes in which an important aspect is the exchange of fluid, heat, or chemical species between fractures and unfractured rock. Examples include production and injection operations in fractured geothermal reservoirs, water-flooding, steamflooding, and other methods for enhanced oil recovery from fractured reservoirs, as well as chemical transport and contaminant migration in fractured rock. MINC can only be applied to media in which the fractures are sufficiently well connected so that a continuum treatment of flow in the fracture network can be made.
...AquaMagna Water Conditioner and Descaler OCETA Environmental Technology & Business Profiles AQUAMAGNA WATER CONDITIONER AND DESCALER CAT. #03-018 CONTACT: Magna-Tek ...removal high-strength ceramic magnet no energy input The AquaMagna Water Conditioner and Descaler is a non-chemical method of water treatment. The technology uses ... Figure 1: The AquaMagna Water Conditioner and Descaler PROCESS/ PRODUCT APPLICATION: hard water domestic water process water reverse osmosis heatexchangers cooling ... For once-through or recirculating heating or cooling equipment, the AquaMagna descaler improves thermal efficiencies and reduces downtime. Figure 2 illustrates a cross-section ...
A numerical investigation of a humidification dehumidification desalination (HDD) process using solar energy is presented. The HDD system consists mainly of a concentrating solar water heating collector, flat plate solar air heating collector, humidifying tower and dehumidifying exchanger. Two separate circulating loops constitute the HDD system, the first for heating the feed water and the second for heating air. A mathematical model is developed, simulating the HDD system, to study the influence of the different system configurations, weather and operating conditions on the system productivity. The model validity is examined by comparing the theoretical and experimental results of the same authors. It is found that the results of the developed mathematical model are in good agreement with the experimental results and other published works. The results show also that the ...
A numerical investigation of a humidification dehumidification desalination (HDD) process using solar energy is presented. The HDD system consists mainly of a concentrating solar water heating collector, flat plate solar air heating collector, humidifying tower and dehumidifying exchanger. Two separate circulating loops constitute the HDD system, the first for heating the feed water and the second for heating air. A mathematical model is developed, simulating the HDD system, to study the influence of the different system configurations, weather and operating conditions on the system productivity. The model validity is examined by comparing the theoretical and experimental results of the same authors. It is found that the results of the developed mathematical model are in good agreement with the experimental results and other published works. The results show also that the ...
This Conference is a key technology transfer activity supported by the ongoing Combustion Equipment Technology (Oil-Heat R and D) program at BNL, and is aimed at providing a forum for the exchange of information among international researchers, engineers, manufacturers, and marketers of oil-fired space-conditioning equipment. The objectives of the Conference were to: identify and evaluate the state-of-the-art and recommend new initiatives for higher efficiency, a cleaner environment, and to satisfy consumer needs cost-effectively, reliably, and safely; and foster cooperation among federal and industrial representatives with the common goal of sustained national economic growth and energy security via energy conservation. The 1996 Oil Technology Conference comprised: (a) fourteen technical papers, and (b) four workshops which focused on mainstream issues in oil-heating technology, namely: oilheat research agenda forum; fan ...
This report documents the Proceedings of the 1995 Oil Heat Technology Conference and Workshop, held on March 22-23 at Brookhaven National Laboratory (BNL), and sponsored by the U.S. Department of Energy - Office of Building Technologies (DOE-OBT), in cooperation with the Petroleum Marketers Association of America. This Conference, which was the ninth held since 1984, is a key technology transfer activity supported by the ongoing Combustion Equipment Technology (Oil-Heat R&D) program at BNL, and is aimed at providing a forum for the exchange of information among international researchers, engineers, manufacturers, and marketers of oil-fired space-conditioning equipment. The objectives of the Conference were to: (1) Identify and evaluate the state-of-the-art and recommend new initiatives for higher efficiency, a cleaner environment, and to satisfy consumer needs cost-effectively, reliably, and safely; (2) Foster ...
Heat transfer augmentation due to surface radiation in an annulus with fins was investigated both theoretically and experimentally for fully developed laminar flow. The system considered in the present study was an array of axially internal and straight fins attached to the outer tube wall. Analytical solutions were given for 4, 8, 16, 24, 32 fins and for the ratios of the fin height to the passage clearance, 0, 0.2, 0.4, 0.5, 0.6, 0.8. The experiments were performed with air as the working fluid for radius ratio of 1.45, 16 fins and for Reynolds numbers ranging from 500 to 2000. The numerically predicted results of the convective/radiative heat transfer for the present case were in good agreement with the experimental data. It was found that the heat transfer augmentation coefficient attained a maximum value of 1.45 for 32 fins and for a dimensionless fin height of 0.65.
Introduction of geothermal heat pump systems, which depend on temperature differential, is investigated for urban areas, which have large energy demands. Results of the surveys on the current situations of geothermal heat pump (GHP) systems indicate that they have already numbered 300,000 units in USA and totaled more than 50,000 units in Switzerland and Northern European countries, and that they are increasing at an annual rate of higher than 10%. The results also indicate that introduction of these systems are well feasible in Japan, which generally has better topographical conditions than American and European countries, and the GHP system with vertical ground heatexchanger is investigated for its topographical and environmental considerations. These systems could annually abate approximately 52 million tons of CO2 (4.3% decrease), if disseminated to all households. They are also expected to help ...
This paper describes the modeling of horizontal steam generator with the TRACE code and calculation results of a loss-of-feedwater (LOF-10) experiment at the PACTEL facility. Parallel Channel Test Loop (PACTEL) is an integral test facility for a VVER-440 type nuclear reactor. The main objectives were to prepare a simulation model for its horizontal steam generator with the TRACE thermal hydraulic code and assess different modeling options of the code. PACTEL experiment LOF-10 was chosen for this assessment. The calculation results showed that TRACE is capable in simulating horizontal steam generator behavior both in steady state and during loss-of-feedwater transient. The phenomenon of heat transfer from primary to secondary side, steam superheating and flow reversal in the lowest heatexchange tubes were studied in detail. Different nodalization options were introduced. In the simulation of PACTEL loss-of-feedwater ...
This paper describes the modeling of horizontal steam generator with the TRACE code and calculation results of a loss-of-feedwater (LOF-10) experiment at the PACTEL facility. Parallel Channel Test Loop (PACTEL) is an integral test facility for a VVER-440 type nuclear reactor. The main objectives were to prepare a simulation model for its horizontal steam generator with the TRACE thermal hydraulic code and assess different modeling options of the code. PACTEL experiment LOF-10 was chosen for this assessment. The calculation results showed that TRACE is capable in simulating horizontal steam generator behavior both in steady state and during loss-of-feedwater transient. The phenomenon of heat transfer from primary to secondary side, steam superheating and flow reversal in the lowest heatexchange tubes were studied in detail. Different nodalization options were introduced. In the simulation of PACTEL loss-of-feedwater ...
Copper tubes have been widely used for water supply and heatexchangers. In such systems copper tubes often suffer from type 1 pitting-corrosion. A mechanism, of the type I pitting-corrosion on copper tubing has been presented, but a initiation mechanism of the pitting corrosion is still unknown. In this paper we aimed to clarify the initiation mechanism of the pitting corrosion. Copper-tube specimens were immersed in a circulating solution. The solution had been used for heatexchangers at a Japanese factory where the water leakage occurred by the pitting corrosion on copper tubes. The solution contained tiny precipitates resulted from corrosion of galvanized steel pipe. During the immersion test changes in the surface state of a copper tube was analyzed by in situ RAMAN (in situ Raman Spectroscopy), SEM (Scanning Electron Microscope), EPMA (Electron Probe Microanalysis), AES (Auger Electron ...
At a military base in the Southeastern US, an energy services company (ESCO) has proposed to retrofit more than 1,000 family residences with geothermal heat pumps as part of an energy savings performance contract (ESPC). Each residence is to have one heat pump with its own ground heatexchanger consisting of two or more vertical bores. A design firm hired by the ESCO sized the heat pumps to meet peak cooling loads, and sized the borefields to limit the maximum entering water temperature (EWT) to the heat pumps to 95 F (35 C). Because there is some disagreement in the geothermal heat pump industry over the peak temperature to be used for design (some designers and design manuals recommend temperatures as low as 85 F[29 C], while equipment manufacturers and others specify temperatures of 100 F[38 C] or higher) the authors were requested to ...
In recent years, several larger geothermal heat pump plants for offices or commercial areas have been designed and built in the central region of Germany, mainly in the Rhein-Main area. Systems with borehole heatexchangers (BHE; in the USA the term Vertical Loop is commonly used) as well as with shallow geothermal doublets (groundwater wells) are operational. New solutions had to be found to adapt the technology to certain site constraints, and innovative components such as thermally-enhanced grouting material have been used. This paper reviews the early development of Ground Source Heat Pumps (GSHP) for commercial buildings, gives details on a number of recent plants and discusses problems that arose during their realisation: UEG Wetzlar, a building with chemical laboratories and one of the first examples of direct cooling from BHE; DFS Langen (German Air Traffic Control Headquarters), with 154 BHE ...
Small circular and noncircular channels are representative of flow passages in compact evaporators and condensers. This paper describes results of an experimental study on heat transfer to the flow boiling of refrigerant- 12 in a small circular tube of diameter = 2.46 mm. The objective of the study was to assess the effect of channel size on the heat transfer coefficient and to obtain additional insights relative to the heat transfer mechanisms. The flow channel was made of brass and had an overall length of 0.9 m. The channel wall was electrically heated, and temperatures were measured on the channel wall and in the bulk fluid stream. Voltage taps were located at the same axial locations as the stream thermocouples to allow testing over an exit quality range of 0.21 to 0.94 and a large range of mass flux (63 to 832 kg/m{sup 2}s) and heat flux (2.5 to 59 kW/m{sup 2}). Saturation ...
Iron deficiency did not enhance absorption of plutonium following intragastric gavage of rats. Absorption of plutonium citrate in both control and iron-deficient rats was about 0.03% of the administered dose.
Many commercial processes for the removal of carbon dioxide from high-pressure gases use aqueous potassium carbonate systems promoted by secondary amines. This paper presents thermodynamic and kinetic data for aqueous potassium carbonate promoted by piperazine. Research has been performed at typical absorber conditions for the removal of CO{sub 2} from flue gas. Piperazine, used as an additive in 20-30 wt% potassium carbonate, was investigated in a wetted-wall column using a concentration of 0.6 m at 40-80{sup o}C. The addition of 0.6 m piperazine to a 20 wt% potassium carbonate system decreases the CO{sub 2} equilibrium partial pressure by approximately 85% at intermediate CO{sub 2} loading. The distribution of piperazine species in the solution was determined by proton NMR. Using the speciation data and relevant equilibrium constants, a model was developed to predict system speciation and equilibrium. The addition of 0.6 m piperazine to 20 wt% potassium carbonate increases the rate ...
This paper presents thermodynamic and kinetic data collected for aqueous blends of piperazine (PZ), an ethylamine, and potassium carbonate (K{sub 2}CO{sub 3}). Mixtures of K{sup +} and PZ have been investigated in a wetted-wall column at 40 to 80{sup o}C, typical conditions for an industrial absorber. The addition of 0.6 m PZ to 20 wt% (3.6 m) K{sub 2}CO{sub 3} increases the rate of CO{sub 2} absorption by a factor of ten from the value in unpromoted solutions at 60{sup o}C. The addition of PZ increases the heat of absorption from 4 kcal/mol in 3.6 m K{sup +} to 10 kcal/mol when 0.6 m PZ is added. The capacity, ranging from 0.4 to 0.7 mol-CO{sub 2}/kg-H{sub 2}O, approaches that of monoethanolamine (MEA) solutions and seems to be a strong function of K{sup +} concentration. Speciation of the solution was obtained using proton nuclear magnetic reasonance (NMR), verifying and quantifying the presence of three PZ species. An ...
In order to demonstrate possible specific effects of microwaves at the cellular level V-79 Chinese hamster cells were exposed to 2.45-GHz radiation at power levels of 20-200 mW/cm2 and at specific absorption rates of 10-100 mW/g. Intracellular cytoplasmic changes were observed by fluorescence polarization using a method based on the intracellular enzymatic hydrolysis of nonfluorescent fluorescein diacetate (FDA). At levels of absorbed energy below 90 J/g, modifications of microviscosity and mitochondrial state were absent, but a slight stimulation of enzymatic hydrolysis of FDA was observed which may be explained by microwave-induced alterations of cellular membranes possibly due to differences in heating pattern of microwaves compared to water-bath heating. At levels of absorbed energy above 90 J/g, the decrease of enzymatic hydrolysis of FDA, increase in degree of polarization, and increase of permeation of the ...
Introduced herein is microwave irradiation for the adsorption and desorption of environmental pollutants. Microwaves may be used in two ways, other than through elevation of temperature of a system as a whole with the adsorbent such as activated carbon serving as the heating medium. The first is the application by which desorption is caused to take place of specified molecules. For example, zeolite that has adsorbed water is regenerated when it is irradiated with microwaves in a stream of cooling gas. This is because only the moisture is heated since zeolite is a non-carbon adsorbent that absorbs microwaves but a little. Another case is reported in which microwaves are utilized to desorb H2S, H2O, CO, etc., from molecular sieves. In the second application, coexisting materials different in absorptivity are exposed to irradiation. The adsorption of microwave-absorbent materials is inhibited while that of the others is ...
Gyrokinetic particle simulation of edge pedestal formation and plasma rotation dynamics will be presented, and compared with experimental observations. Realistic tokamak edge geometry is used which include separatrix/X-point and material wall from EFIT g-eqdsk data. In order to handle adequately the spatially inhomogeneous electric potential in the scrape-off region, the full-f electron technique is used, in addition to the full-f ions. Monte Carlo neutral particles with wall recycling coefficient will be included self-consistently with the plasma kinetics. Ion-ion Coulomb collisions will be particle, momentum and energy conserving. Energy source for the pedestal and scrape-off plasmas is the heat flow from the core plasma, and the particle source is the ionization of the neutral atoms which are either wall recycled and/or gas puffed. The simulation will be self-consistent with the first principles nonlinear neoclassical and (electrostatic so far) turbulence ...
The possibilities for heat recovery in a cast iron melting furnace were studied. A cupola furnace which produces 40 tonnes steel per hour, produces 25,000 Nm/sup 3//h of flue gases which contain 16-22% CO. Taking into account the heat losses at the chimney where fumes are cooled to 200/sup 0/C the recoverable heat is about 12.4-10/sup 6/ kcal/h which mainly consists of combustion heat in CO. This study showed that the heat can be used for the production of electricity, which will be used in the plant. Recovery of 87 kWh of electricity per tonne of steel produced is possible. A steam turbine driven generator of 3.5 MW will be required. The combustion of the low calorific gas (approximately 400 kcal/Nm/sup 3/) has been studied and gave positive results: wet CO gas can be burnt without addition of methane and preheating of air is not required. The pilot plant consisting of a thermic ...
A solar-driven 10-ton LiBr/H2O single-effect absorption cooling system has been designed and installed at the School of Renewable Energy Technology (SERT), Phitsanulok, Thailand. Construction took place in 2005, after which this system became fully operational and has been supplying cooling for our main testing buildings air-conditioning. Data on the systems operation were collected during 2006 and analyzed to find the extent to which solar energy replaced conventional energy sources. Here, we present these data and show that the 72m2 evacuated tube solar collector delivered a yearly average solar fraction of 81%, while the remaining 19% of thermal energy required by the chiller was supplied by a LPG-fired backup heating unit. We also show that the economics of this cooling system are domi...
Heat production in biological materials due to absorption of radiowaves and microwaves can be used in applications as diverse as cancer treatment and cooking. However, the hazards of overexposure range from hyperthermia to cataracts and internal burns. To maximize the clinical benefits and minimize potential hazards, the biological effects of radiowaves and microwaves must be understood. Dielectric measurements can be used to determine the extent of such effects in various applications and at various levels of exposure. The values of maximum permissible exposure levels that are likely to be recommended aeat production in biological materials due to absorption of radiowaves and microwaves can be used in applications as diverse as cancer treatment and cooking. However, the hazards of overexposure range from hyperthermia to cataracts and internal burns. To maximize the clinical benefits and minimize potential hazards, the ...
Development of a Comprehensive Decontamination Database and an Absorption-Electrochemical Metal Surface Decontamination Technique Combining Chemical and Electrochemical Process
The work in the past year has primarily involved four areas of magnetic thin films: amorphous rare earth-transition metal alloys, epitaxial CoPt{sub 3} and Ni-Pt alloy thin films, amorphous rare earth doped Si (a new class of dilute magnetic semiconductor with large negative magnetoresistance which the authors have discovered), and exchange-coupled antiferromagnetic insulators. In the amorphous alloys, they made a systematic study of the effects of local anisotropy, macroscopic (perpendicular) anisotropy, and exchange constant on the fundamental (and practical) properties of these magnetic alloys, as originally described in the grant proposal. The work on the epitaxial Co-Pt (and more recently Ni-Pt) alloys was originally undertaken as a comparison study to the amorphous alloys. Crystalline Co-Pt alloys have many striking similarities to the amorphous rare earth-transition metal alloys: perpendicular magnetic anisotropy, magneto-optic activity, ...
TSS (thermal swing sublimation) method was studied which uses vaporization heat and sensible heat of LNG for solidification and separation of CO2 gas in waste gases of LNG-fired combined cycle power generation system. In experiment, the mixed gas composed of CO2, H2O and N2 was used for simulating waste gas of LNG-fired combined cycle power generation systems, and the growth behavior of ice and dry ice was studied for developing dry ice making technology under low-temperature condition. As the experimental result, the following were clarified: various crystal structures depending on cooling temperature, the effect of gas flow rate on peeling of surface precipitated solids, and solidification characteristics of H2O/CO2 mixed gas. The growth rate of precipitated solid film thickness decreased with an increase in gas flow rate, while increased with CO2 concentration. The shape of a dry ice sublimator similar to that of a fluidized bed ...
The INCO ``INCOLOY 800`` trademark groups the Fe-Cr-Ni alloys containing 30 to 35% nickel, 19 to 23% chromium, 0,15 to 0,60% aluminium, 0,15 to 0,60% titanium and less than 0,10% carbon contents, used as construction materials for condenser and heatexchanger tubes. In parallel with water chemistry control and studies aimed at reducing the residual stresses resulting from tube expansion, studies have been conducted to a better understanding of this alloy, its metallurgy and its corrosion behaviour under accurately defined fabrication and heat treatment conditions. The purpose of this paper is to present the results of a behaviour study of INDRET alloy 800 concerning isothermal relaxation and effects of the said relaxation heat treatments on alloy microstructure studied with a transmission electron-chemical method to determine the sensitiveness to intergranular corrosion, and by electrochemistry in ...
Alloy 800 was developed in 1949 by The International Nickel Company, Inc. The basic composition, nominally 32wt.%Ni, 20.5wt.%Cr and 46wt.%Fe, was designed to provide a stable, fully austenitic structure and to impart high strength combined with resistance to oxidation, carburization and corrosion in a wide variety of aggressive industrial environments at elevated temperatures. In the short span of twenty-five years, alloy 800 has earned a unique position in the family of heat- and corrosion-resistant materials. Established uses include a wide range of applications in the industrial heating field, in the petro-chemical industry, in domestic appliances and in food processing equipment. The good performance of alloy 800 in these applications has led to its use as boiler tube material both in fossil-fired plants and in HTGR and PWR nuclear power systems. Recently, it was specified for a PHW CANDU reactor and it is now being considered as ...
The present paper deals with the fouling process of calcium sulfate dehydrate on heat-transfer surfaces. The crystallization of calcium sulfate showed typical asymptotic fouling curves, the asymptotic value of which was greatly influenced by the surface temperature and fluid velocity. The fouling mechanism was discussed with a generalized fouling model and proved to be surface process controlled, where the activation energy was 6.2 {times} 10{sup 4} J/mol. The availability of mechanical cleaning against the formed scale was quantitatively evaluated by applying the particle abrasion method. The removal test verified that the removing rate per unit particle concentration decreased in an inverse proportion to the overall particle load, to the power of 0.8, and that it was affected by the fluid velocity. The observed final residual fouling resistance decreased asymptotically with an increase in particle concentration. The suitable concentration of the abrasive ...
The gastrointestinal absorption of lead was markedly increased in human subjects who had fasted before ingesting lead. Food in the gut was found to reduce lead absorption, and the effect of dietary constituents on /sup 203/Pb absorption was investigated. The greatest reduction in absorption was caused by minerals. This dependence of lead absorption on dietary constituents complicates the establishment of safe levels of lead in food and water.
The design of a gaging head for a portable radionuclide X-ray fluorescence analyzer is described. The gaging head is designed as a construction unit system which enables the application of lateral reflexion geometry as well as of coaxial geometry. It is designed so that adjustment from one geometry to the other is labour and time saving. The selection of characteristic radiation is performed by a couple of Ross' differential filters. These filters are prepared by a novel technique developed by our laboratory. The filter exchange is effected by the longitudinal move of the couple of filters encapsulated in a holder. The shift of the filters is controlled by means of a triggering mechanism situated in the body of the gaging head handle. This design makes is possible to handle the gaging head during measurements with one hand. A simple interchange of the absorption filter for the transmissive filter allows the operator to avoid any unwanted shift ...
This paper, firstly, introduces the background in developing a high quality water supply system, in which the drinking water system is isolated inside a building. Results of questionnaire on the high quality service water are illustrated. The results of questionnaire have revealed that the high quality service water is extremely interested. Then, are described the target quality of high quality water, the constitution of high quality water supply system, the treatment process, the measures to secure safety and sanitary, and the method of maintenance. The high quality water is produced through the activated charcoal absorption treatment, membrane treatment, ozonation, cooling, mineral addition, and disinfection of city water. Furthermore, application examples of this system adopted to a department store and a bachelor apartment house are introduced. For the high quality water supply system in the department store, the activated charcoal treatment was employed. For ...
Crystal field calculation and electron paramagnetic resonance (EPR) have been performed on zircon-type materials Nd:YMO{sub 4} (M=V, As, P). Simulation of the energy level schemes has been carried out and the wave functions composition and g tensor principal values associated to the first sub-level of the {sup 4}I{sub 9/2} manifold were calculated. A rather good correlation is obtained between crystal field calculations and the EPR measurements. Furthermore, some extra lines observed by optical spectroscopy (absorption and emission) also appear on the EPR spectra and a correlation between the two spectroscopies indicates that Nd{sup 3+}-Nd{sup 3+} exchange and dipolar interactions occur in the zircon family, even at very low doping content (less than 8 x 10{sup 19} Nd{sup 3+} ions cm{sup -3}). Nd{sup 3+}-Nd{sup 3+} pairs at distances 3.9, 5.9 and 6.3 A have been identified. (orig.) 13 refs.
Crystal field calculation and electron paramagnetic resonance (EPR) have been performed on zircon-type materials Nd:YMO_4 (M=V, As, P). Simulation of the energy level schemes has been carried out and the wave functions composition and g tensor principal values associated to the first sub-level of the "4I_9_/_2 manifold were calculated. A rather good correlation is obtained between crystal field calculations and the EPR measurements. Furthermore, some extra lines observed by optical spectroscopy (absorption and emission) also appear on the EPR spectra and a correlation between the two spectroscopies indicates that Nd"3"+-Nd"3"+ exchange and dipolar interactions occur in the zircon family, even at very low doping content (less than 8 x 10"1"9 Nd"3"+ ions cm"-"3). Nd"3"+-Nd"3"+ pairs at distances 3.9, 5.9 and 6.3 A have been identified. (orig.)
On-board reforming of liquid fuels to hydrogen for use in proton exchange membrane (PEM) fuel cell electric vehicles (FCEVs) has been the subject of numerous investigations. In many respects, liquid fuels represent a more attractive method of carrying hydrogen than compressed hydrogen itself, promising greater vehicle range, shorter refilling times, increased safety, and perhaps most importantly, utilization of the current fuel distribution infrastructure. The drawbacks of on-board reformers include their inherent complexity [for example a POX reactor includes: a fuel vaporizer, a reformer, water-gas shift reactors, a preferential oxidation (PROX) unit for CO cleanup, heatexchangers for thermal integration, sensors and controls, etc.], weight, and expense relative to compressed H{sub 2}, as well as degraded fuel cell performance due to the presence of inert gases and impurities in the reformate. Partial oxidation (POX) of ...
Ground source heat pumps (GSHPs), often referred to as geothermal heat pumps (GHPs), offer an attractive option for heating and cooling residential and commercial buildings owing to their higher energy efficiency compared with conventional systems. GSHPs have been used for four years in the Turkish market, although they have been in use for more years in developed countries. The purpose of this study is to present an energy and exergy analysis of a GSHP system with a 50 m vertical 1.25 in. nominal diameter U-bend ground heatexchanger. This system was applied to a 65 m"2 room in the Solar Energy Institute, Ege University, Izmir, for the first time at the university level in Turkey. The Institute, built in 1986, has a livable floor area of 3000 m"2 and uses passive solar techniques. The heating and cooling loads of the room studied were 3.8 and 4.2 kW at design ...
The current work continues a project completed in 1999 by ReMaxCo Technologies in which a novel, microwave based, VLS Silicon Carbide Fibrils concept was verified. This project continues the process development of a pilot scale commercial reactor. Success will lead to sufficient quantities of fibrils to expand work by ORNL and others on heatexchanger tube development. A semicontinuous, microwave heated, vacuum reactor was designed, fabricated and tested in these experiments. Cylindrical aluminum oxide reaction boats are coated, on the inner surface, with a catalyst and placed into the reactor under a light vacuum. A series of reaction boats are then moved, one at a time, through the reactor. Each boat is first preheated with resistance heaters to 850 C to 900 C. Each reaction boat is then moved, in turn, to the microwave heated section. The catalyst is heated to the required ...
There is a crescent interest in the scientific community in the study of natural circulation phenomenon. New generation of compact nuclear reactors uses the natural circulation of the fluid as a system of cooling and of residual heat removal in case of accident or shutdown. The objective of this paper is to present a study through the comparison of experimental data and numerical simulation for the natural circulation phenomenon in one and two-phase flow regime. An experimental circuit built with glass tubes is used for the experiments. Thus, it allows the thermal hydraulic phenomena visualization. There is an electric heater as the heat source, a heatexchanger as the heat sink and an expansion tank to accommodate fluid density excursions. The circuit instrumentation consists of thermocouples and pressure meters to better keep track of the flow and heat ...
Pulsed atomic beams produced in vacuum by laser induced ablation from a lithium target are analyzed by laser induced fluorescence (LIF). The 1-mixing processes induced in the n = 9, 10 Li Rydberg states by collisions with CO_2 molecules illustrate the application of the method. Resolution is limited by the 1 mm diameter of the probe laser beam. Combining LIF and absorption measurements gives n_L_i as a function of time at various distances from the target surface. The investigation of the Li-C0_2 1-mixing process in a heat pipe oven proved impossible due to the high reactivity of Li with C0_2. This problem was solved by renewing the Li atoms at each laser shot. Values obtained for n = 9, n = 10 are k = 17 x 10"-"8 and 15 x 10"-"8 cc/sec, respectively.
The microdynamics of soliton waves and localized modes of nonlinear vibrations of the acoustic and optical types in uranium nitride has been investigated. It has been shown that, with an increase in the excitation energy in the spectral gap between the bands of optical and acoustic phonons, the energies of solitons increase, whereas the energies of local modes decrease. The previously experimentally observed unidentified quasi-resonant features, which shift in the gap with variations in the temperature, can represent the revealed soliton waves and local modes. The microdynamics of heat conduction of uranium nitride has been studied for the stochastic generation of soliton waves and local modes in the case of spatially distant energy absorption. The thermal conductivity coefficient determin...
A method for determining the mobility of hydrogen as a function of temperature in superconducting niobium cavities comprising: 1) heating a cavity under test to remove free hydrogen; 2) introducing hydrogen-3 gas into the cavity; 3) cooling the cavity to allow absorption of hydrogen-3; and 4) measuring the amount of hydrogen-3 by: a) cooling the cavity to about 4.degree. K while flowing a known and regulated amount of inert carrier gas such as argon or helium into the cavity; b) allowing the cavity to warm at a stable rate from 4.degree. K to room temperature as it leaves the chamber; and c) directing the exit gas to an ion chamber radiation detector.
In this study we discuss an unsteady free convection MHD flow past semi-infinite vertical porous plate. We have considered the flow in the presence of a strong magnetic field and therefore the electromagnetic force is very large. This brings in the phenomenon of Hall and Ion-slip currents. The effects of these two parameters together with that of viscous dissipation and radiation absorption among others on velocity, temperature and concentration profiles are presented. The profiles are presented graphically. As the partial differential equations governing this problem are highly non-linear they are solved numerically by a finite difference method. It is found that in presence of heating of the plate by free convection current the velocity boundary layer thickness decreases.
In this study we discuss an unsteady free convection MHD flow past semi-infinite vertical porous plate. We have considered the flow in the presence of a strong magnetic field and therefore the electromagnetic force is very large. This brings in the phenomenon of Hall and Ion-slip currents. The effects of these two parameters together with that of viscous dissipation and radiation absorption among others on velocity, temperature and concentration profiles are presented. The profiles are presented graphically. As the partial differential equations governing this problem are highly non-linear they are solved numerically by a finite difference method. It is found that in presence of heating of the plate by free convection current the velocity boundary layer thickness decreases.
The interaction of thermal radiation with conduction and convection in thermally developing absorbing, emitting, nongray gas-particulate turbulent suspension flow through a circular tube is investigated. The contribution of thermal radiation is obtained through evaluation of the total hemispherical emittance of the particulate cloud and through evaluation of single band absorptances for molecular gases, modified to account for the interaction with the particles. The governing differential equation is derived as a (nonlinear) energy equation, coupled with integral equations to find the thermal radiation contributions. The energy equation is solved numerically by an implicit finite difference method with an iterative procedure. Qualitative results for Nusselt numbers are shown for a variety and range of parameters, such as optical thickness of particulates and single molecular gas bands, relative gas band position and band width, and temperature ratios ...
The interaction of thermal radiation with conduction and convection in thermally developing absorbing, emitting, non-gray gas particulate turbulent suspension flow through a circular tube is investigated. The contribution of thermal radiation is obtained through evaluation of the total hemispherical emittance of the particulate cloud and through evaluation of single band absorptances for molecular gases, modified to account for the interaction with the particles. The governing differential equation is derived as a (nonlinear) energy equation, coupled with integral equations to find the thermal radiation contributions. The energy equation is solved numerically by an implicit finite difference with its iterative procedure. Qualitative results for Nusselt numbers are shown for a variety and range of parameters, such as optical thickness of particulates and single molecular gas bands, relative gas band position and band width, and temperature ratios ...
Hierarchical TiO2 hollow spheres had been prepared based on bubble templates by a simple one-step hydrothermal method. The diameter of hollow spheres was about 700nm and the shell thickness of them was 69nm. They were composed of similar spindle- or needle-like building units. Furthermore, hydrothermal time had an important influence on the morphology and crystallinity of hollow spheres. Moreover, the UV-Vis diffuse reflectance spectra of TiO2 hollow spheres heated at 150^oC for 10h showed the strongest absorption in the UV-Vis region and the Raman spectrum demonstrated the anatase sample. Additionally, a possible formation mechanism of TiO2 hollow spheres was proposed. So this novel and simple method would provide a development direction to fabricate all kinds of inorganic hollow spheres ...
A cone concentrator combined with a solar cavity receiver is presented and its performance compared to a single cavity receiver. For both cases the available heat sink within the receiver is calculated. The cone concentrator suffers from a high amount of rejected rays if the exit aperture is made too small. A larger exit aperture on the other hand increases the thermal losses of the cavity. The optimum cone geometry therefore has to be found taking also into account a model of the cavity. Different operating temperatures and different values of absorption coefficients of the cavity walls are considered. A cone concentrator was built and tested at the solar furnace in Cologne. It transmits 97 percent of the rays entering the entrance aperture, which is in exact agreement with the theoretical predictions. (author)
Two-phase flow patterns and frictional pressure gradients in flow in small, rectangular channels are being studies as part of a larger research program addressing phase-change heat transfer of pure refrigerants and refrigerant mixtures in plate-fin heatexchangers. Small rectangular flow channels were selected as representative of plain fin geometries. The particular channel reported herein has dimensions of 19.05 {times} 3.18 mm. Adiabatic flows of air/water mixtures, with the flow channel horizontal and the channel exit at near-atmospheric conditions, were utilized in the experiments. Analysis and interpretation of the pressure data relative to observed flow pattern transitions led to an objective method for determining the plug/bubble-to-slug flow transition. This method, together with visual observations, supplemented with photographic data, was used to develop a flow pattern man. A comparison of existing flow pattern ...
A thermophotovoltaic (TPV) generator for electric vehicles has been designed and developed. In this paper we focus on the combustion system and the heat regenerator. The system has been designed to work as a range extender for electric vehicles. This solution would provide energy always available on the vehicle, which would run even if the battery level were low. Several configurations for the burner and for the heatexchanger have been investigated and a comparison of these is presented. The different solutions have been studied both theoretically and experimentally. In this paper, we report on the work carried out to build a TPV device capable of yielding 6 kW of electric power to recharge the battery pack of an electric city-car. The project has been divided into four steps: (1) pre-design of different configurations of the burner and heatexchanger using non-commercial software ...
Climates at regional scale are strongly dependent on the interaction between atmosphere and its lower boundary, the oceans and the land surface mosaic. Land surfaces influence climate through their albedo, and the aerodynamic roughness, the processes of the biosphere and many soil hydrological properties; all these factors vary considerably geographically. Land surfaces receive a certain portion of the solar irradiance depending on the cloudiness, atmospheric transparency and surface albedo. Short-wave solar irradiance is the source of the heat energy exchange at the earth`s surface and also regulates many biological processes, e.g. photosynthesis. Methods for estimating solar irradiance, atmospheric transparency and surface albedo were reviewed during the course of this project. The solar energy at earth`s surface is consumed for heating the soil and the lower atmosphere. Where moisture is available, evaporation is one of ...
Biosorption using activated sludge biomass (ASB) as a potentially sustainable technology for the treatment of wastewater containing different metal ions (Cd(II), Pb(II) and Zn(II)) was investigated. ASB metal uptake clearly competed with protons consumed by microbial biomass compared with control tests with non-activated sludge biomass. Biosorption tests confirmed maximum exchange between metal ions and protons at pH 2.0-4.5. It was revealed by the study that the amount of metal ions released from the biomass increased with biomass sludge concentration. The result showed that maximum absorption of metal ions was observed for Cd(II) at pH 3.5, Pb(II) at pH 4.0, and pH 4.5 for Zn(II) ions. The maximum absorption capacities of ASB for Cd(II), Pb(II) and Zn(II) were determined to be 59.3, 68.5 and 86.5%, respectively. The biosorption of heavy metals was directly proportional to ASB stabilization corresponding to a reduction in ...
Magnetite nanoparticles with high self-heating capacity and low toxicity characteristics are a promising candidate for cancer hyperthermia treatment. In order to achieve minimum dosage to a patient, magnetic nanoparticles with high heating capacity are needed. In addition, the influence of physiological factors on the heat capacity of a material should be investigated in order to determine the feasibility. In this study, magnetite nanoparticles coated with lauric acid were prepared by co-precipitation of Fe{sup 3+}:Fe{sup 2+} in a ratio of 2:1, 5:3, 3:2, and 4:3, and the pH was controlled using NaOH. Structural and magnetization characterization by means of X-ray diffractometry (XRD) and a superconducting quantum interference device (SQUID) revealed that the main species was Fe{sub 3}O{sub 4} and further showed that most of the nanoparticles exhibited superparamagnetic properties. All of the magnetic nanoparticles showed a ...
The paper is Part 2 of the study on the thermodynamic and thermoeconomic analyses of trigeneration system with a gas-diesel engine. In Part 1, thermodynamic and thermoeconomic methodologies for such a comprehensive analysis were provided, while this paper applies the developed methodology to an actual TRIGEN system with a rated output of 6.5 MW gas-diesel engine installed in the Eskisehir Industry Estate Zone, Turkey. Energy and exergy efficiencies, equivalent electrical efficiency, the Public Utility Regulatory Policies Act (PURPA) efficiency, fuel energy saving ratio, fuel exergy saving ratio and other thermodynamic performance parameters are determined for the TRIGEN system. The efficiencies of energy, exergy, PURPA and equivalent electrical efficiency of the entire system are found to be 58.97%, 36.13%, 45.7% and 48.53%, respectively. For the whole system and its components, exergetic cost allocations and various exergoeconomic performance parameters are calculated using the ...
The paper is Part 2 of the study on the thermodynamic and thermoeconomic analyses of trigeneration system with a gas-diesel engine. In Part 1, thermodynamic and thermoeconomic methodologies for such a comprehensive analysis were provided, while this paper applies the developed methodology to an actual TRIGEN system with a rated output of 6.5 MW gas-diesel engine installed in the Eskisehir Industry Estate Zone, Turkey. Energy and exergy efficiencies, equivalent electrical efficiency, the Public Utility Regulatory Policies Act (PURPA) efficiency, fuel energy saving ratio, fuel exergy saving ratio and other thermodynamic performance parameters are determined for the TRIGEN system. The efficiencies of energy, exergy, PURPA and equivalent electrical efficiency of the entire system are found to be 58.97%, 36.13%, 45.7% and 48.53%, respectively. For the whole system and its components, exergetic cost allocations and various exergoeconomic performance parameters are calculated using the ...
The shortage of fresh water is increasing at alarming levels, even in temperate zones. Desalination of brackish and seawater is being considered as a solution to growing water demands. Seawater desalination can be accomplished through reverse osmosis, vapor compression, vapor absorption and thermally driven systems. The most suitable process for large-scale desalination plants is successive brine evaporation-condensation with intermediate heat recovery. However, higher process efficiency could be achieved. The use of low temperature heat sources in seawater desalination requires an efficient method of evaporation and condensation at relatively low vapor pressures. This could be achieved in a humidification-dehumidification process using circulated air to enhance evaporation of water. Simulation models, however, neglect either the heat of evaporation or the changes in air and water properties within ...
Electron cyclotron resonance heating (ECH) in BPX is planned as a possible upgrade to supplement the baseline ion cyclotron resonance frequency (ICRF) system. Eventual implementation primarily depends on the development of the required source technology. ECH offers important technical advantages over ICRF: High radio-frequency (FR) power density can be transmitted through ports (P/A >#approx# 100 MW/M"2), and the antenna need not be in contact with the plasma for efficient coupling. In particular, low-field side, linearly polarized (O-mode) power injection will suffice. By controlling the N spectrum, or by steering the antenna, the power deposition profile can be controlled during ramping of the magnetic field even with a fixed frequency source. Because of the possibility of localized power deposition, ECH is a natural candidate for controlling magnetrohydrodynamic (MHD) activity. Sawtooth oscillations may be prevented by heating in the ...
LEDF(Large Equipment Dismantling Facility) is the solid waste processing technology development facility that carries out high-volume reduction and low dosage processing. The high-volume reduction processing of the high dose {alpha}-waste configured with combustible waste, pvc and rubber, spent ion exchange resin, and noncombustible waste have been planned the incinerating and melting facility using the in-can type high frequency induction heating in LEDF. This test is intended to clarify the design data. It was confirmed that the incinerating and melting performance, molten solid properties and exhaust gas processing performance with pilot testing equipment and bench scale equipment. The result of this test are as follows. 1. Processing speed is 6.7 kg/h for the combustible waste, 13.0 kg/h for the ion exchange resin, and 30.0 kg/h for the noncombustible waste. For above optimum processing conditions are as follows. ...
In order to avoid the use of catalysts in the process of auto-thermal reforming, it is possible to adopt a running at high temperature. In this study are presented the results of simulations of an auto-thermal/recuperator hybrid reforming system; these results are obtained with the oxidation model of alkanes developed by Ranzi and Faravelli. An isothermal configuration at high temperature improves the hydrogen yield and avoids the formation of soots. The analysis of the powers to be furnished to assure such an experimental mode, and the global approach of the fuel cell system show that the management of the heatexchanges is a key parameter in this process. (O.M.)
The Superphenix 750-MW (thermal), once-throughtype steam generators are the result of over 10 years of intensive research and development. Detailed design and manufacture of the components lasted from 1977 to 1982. The main difficulties encountered during the construction of these prototype units concerned: demonstration of satisfactory high-temperature properties of Alloy 800 tubes; proven resistance of tube welds to thermal fatigue and of structures and shells to sodium/ water reaction effects; prevention of the tube bundle to flow-induced vibration; necessity of manual welding of shells to prevent hot cracking hazards related to the boron content of the steel; and welding of heatexchange tubes. None of these difficulties, however, invalidated initial major design choices, but provided a wealth of technical and technological experience and knowledge for the steam generators of the future. Plans for the future include revision of the ...
Future power plants will be more fuel efficient, environmentally benign, and economical than current power plants. A high performance power system (HIPPS), based on a coal-fired combined cycle, is currently being developed. The corrosion and temperature-strength properties of currently available metallic materials limit the maximum efficiency of this cycle. Recently, ceramic matrix composites have shown promise in overcoming the design limitations on the future power plants. In particular, the high-temperature, and corrosion and erosion resistant properties of continuous fiber ceramic composites (CFCCs) will allow engineers to design high-temperature heatexchangers, cyclone vortex finder tubes, and other components. Research being performed to evaluate candidate materials for use in future power plants is discussed.
For optimal performances, proton exchange membrane fuel cells require fine water and thermal management. Accurate modelling of the physical phenomena occurring in the fuel cell is a key issue to improve fuel cell technology. Here, an analytic steady state diphasic 2D model of heat and mass transfer is presented. Through this model, the aim of this work is to study the influence of local events on the global performances of a fuel cell. A part of the complete model is a microscopic representation of the coupling between water transport and charge transfers in the electrodes. The thickness of the liquid layer around the reactive agglomerates is deduced from the saturation. The evolution of the quantity of water within the catalyst layer is monitored and its influence on the global performanc...
Chars prepared from potassium-exchanged carboxy methyl cellulose at several heat treatment temperatures (HTTs) were gasified in air isothermally at selected gasification temperatures (GTs) in the range 633-893 K to investigate the catalytic effectiveness of potassium species. The chars displayed a noticeable jump in gasification rate at a particular gasification temperature (called jump temperature, T{sub j}). The magnitude of jump was much less than that reported for copper and nickel catalysis, but comparable with that for calcium catalysis. Increase in HTT caused a decrease in the jump temperature of chars in contrast with the increase observed in copper, nickel and calcium catalysis; also the magnitude of jump did not decrease, but remained unaltered, on increasing HTT. The different behavior of potassium catalysis is correlated to a change in the chemical state of potassium at higher HTT. The results reveal the dependence of jump ...
This paper investigates steels 12Kh18N10T, 10Kh17N13M2T, 08Kh22N6T, and 08Kh21N6M2T. In corrosion of stainless steels in sulfuric acid solutions, dissolved sulfur dioxide acts as a cathodic depolarizer, capable of being reduced to elemental sulfur or forming sulfides with the metal. Depending on the conditions, this is associated with some increase in potential and greater or lesser increase in corrosion or facilitation of passivation of active steel. After passivation the influence of SO/sub 2/ is negligible. The results of this investigation were used as initial data for developing systems of anodic protection for shell-and-tube heatexchangers for sulfuric acid.
The effect of treatment of Na-forms of zeolites with HCl solutions and of heat treatment of their NH/sub 4/-forms on the stability of aluminum-oxygen tetrahedra has been studied in this work by high-resolution NMR on /sup 29/Si nuclei, using the synthetic zeolites X, Y, and M (mordenite) as the objects of the study. The exchange capacity with respect to Na/sup +/ ions was determined by analyzing the equilibrium solutions after contact of the samples with 0.5 NH/sub 4/Cl solution on a flame photometer. The high-resolution /sup 29/Si NMR spectra of polycrystalline samples were recorded on an SKhR-200 spectrometer with a superconducting solenoid at a frequency of 39.75 MHz with ultrafast mechanical rotation (3 kHz) of the sample at the magic angle to the external magnetic field. The results obtained are given.
An exergy analysis method is presented of the solar multi-effect humidification?dehumidification desalination (HDD) process. Pinch technology is used in the humidification process to determine the maximum possible saturated air temperature and the temperature of water rejected from the unit, and then the dehumidification process to determine the temperature of water leaving from the heatexchanger. The formulae to calculate the exergy of water and saturated air are given. The solar plane collector is used. From exergy analysis, the solar collector has the lowest exergy efficiency; the HDD process has a lower exergy efficiency, and the water rejected has also a large exergy loss. The energy and exergy recovery rate of the desalination process is also lower. The solar multi-effect HDD proces...
Heat transfer through the gas diffusion layer (GDL) is a key process in the design and operation of a PEM fuel cell. The analysis of this process requires the determination of the effective thermal conductivity as well as the thermal contact resistance between the GDL and adjacent surfaces/layers. The Part 1 companion paper describes an experimental procedure and a test bed devised to allow separation of the effective thermal conductivity and thermal contact resistance, and presents measurements under a range of static compressive loads. In practice, during operation of a fuel cell stack, the compressive load on the GDL changes. In the present study, experiments are performed on Toray carbon papers with 78% porosity and 5% PTFE under a cyclic compressive load. Results show a significant hy...
Heat transfer through the gas diffusion layer (GDL) is a key process in the design and operation of a PEM fuel cell. The analysis of this process requires determination of the effective thermal conductivity as well as the thermal contact resistance associated with the interface between the GDL and adjacent surfaces/layers. In the present study, a custom-made test bed that allows the separation of effective thermal conductivity and thermal contact resistance in GDLs under vacuum and ambient conditions is described. Measurements under varying compressive loads are performed using Toray carbon paper samples with a porosity of 78% for a range of thicknesses. The measurements are complemented by compact analytical models that achieve good agreement with experimental data. A key finding is that ...
Problems are discussed of heatexchange tubes of Westinghouse type vertical steam generators exhibiting corrosion damage such as point corrosion, planar corrosion, tube denting, corrosion stress cracking, crevice corrosion, fretting corrosion and intergranular corrosion. Attention is also paid to problems of WWER-440 type horizontal steam generators, where the level fluctuation area is critical; noncompact porous deposits of the corrosion products give rise to crevice effects and cause significant concentration of chloride ions and other additions. This problem can be partly resolved by a modification of the collector design at the level variation area. An additional measure is the production of steel 08Kh18N10T with a very low level of harmful elements and inclusions. (Z.M.). 3 figs., 11 refs.
Titanium stabilized austenitic steel is sensitive to SCC in the secondary water under the horizontal steam generator operating conditions. SCC was observed under crevice conditions both at the primary collector flanges and the heatexchange tubes. In the crevice environment sulfates and chlorides as aggressive species and silicates and alumino-silicates as ''non-aggressive'' species are present in significant amounts. Local water chemistry parameters were evaluated using the MULTEQ Code. SCC experiments were carried out by rising displacement tests ar 275 deg C in an environment simulating the crevice conditions. Crack growth rate and K{sub IS}8C{sub C} were determined for the environment where contents of some species were from 10{sup 2} to 10{sup 4} times higher than in blowdowns. (authors)
Titanium stabilized austenitic steel is sensitive to SCC in the secondary water under the horizontal steam generator operating conditions. SCC was observed under crevice conditions both at the primary collector flanges and the heatexchange tubes. In the crevice environment sulfates and chlorides as aggressive species and silicates and alumino-silicates as ''non-aggressive'' species are present in significant amounts. Local water chemistry parameters were evaluated using the MULTEQ Code. SCC experiments were carried out by rising displacement tests ar 275 deg C in an environment simulating the crevice conditions. Crack growth rate and K_I_S8C_C were determined for the environment where contents of some species were from 10"2 to 10"4 times higher than in blowdowns. (authors)
Three experiments were conducted to study the behaviour of the new horizontal steam generator construction of the PACTEL test facility. In the experiments the secondary side coolant level was reduced stepwise. The experiments were calculated with two computer codes RELAP5/MOD3.1 and APROS version 2.11. A similar nodalization scheme was used for both codes so that the results may be compared. Only the steam generator was modeled and the rest of the facility was given as a boundary condition. The results show that both codes calculate well the behaviour of the primary side of the steam generator. On the secondary side both codes calculate lower steam temperatures in the upper part of the heatexchange tube bundle than was measured in the experiments. (orig.) 4 refs.
Three experiments were conducted to study the behaviour of the new horizontal steam generator construction of the PACTEL test facility. In the experiments the secondary side coolant level was reduced stepwise. The experiments were calculated with two computer codes RELAP5/MOD3.1 and APROS version 2.11. A similar nodalization scheme was used for both codes so that the results may be compared. Only the steam generator was modeled and the rest of the facility was given as a boundary condition. The results show that both codes calculate well the behaviour of the primary side of the steam generator. On the secondary side both codes calculate lower steam temperatures in the upper part of the heatexchange tube bundle than was measured in the experiments. (orig.).
Abstract Jicama (Pachyrhizus erosus L.) is a root-based legume that has been cultivated in Mexico for centuries. Pectic polysaccharide from de-starched jicama pomace was extracted using an autoclave-assisted process and physicochemically characterized. The extracted polysaccharide (1.0 g L-1) was used for the formation of polyelectrolyte complexes (PECs) with water-soluble chitosan (WSCh; 0.5, 1.0 and 2.0 g L-1). The extraction yield of jicama pectic polysaccharide was 22.8 wt% (dry basis) and infrared spectroscopic analysis showed that it was methoxylated to a small degree. Thermogravimetric analysis indicated that this biopolymer was very stable, its weight loss being 51.2% after heating at 479 C. Anion-exchange chromatography showed it to have a wide and heterogeneous charge density. Th...
Investigatins into the welding of alloy 800 at the Reactor Fuel Element Laboratories, Springfields, commenced about three years ago following an extended development programme on tube to tube plate welding of low alloy and stainless steels for the Prototype Fast Reactor. The techniques and approach developed for critical fuel element welding applications had proved equally suitable for the precision welding requirements on the much heavier sections of heatexchangers. It had been demonstrated that the same control of weld quality and profile could be achieved with consistency and the permissible range of critical parameters could be readily defined. Because of this, development work was continued to include other materials, such as alloy 800, which might be of potential use. The tungsten inert gas (T.I.G.) arc welding process is used, and the equipment, including the control system, is described. Tube to tube-plate welding, and tube to tube ...
The thermal energy storage performance and phase change stability of mix phase change materials consisted of stearic acid and Na{sub 2}PO{sub 4}.12H{sub 2}O are studied by means of Fourier transformation infrared spectrum analyses (FTIR) and Differential Scanning Calorimetry (DSC). The specific heat capacity of mix materials is also determined experimentally. The results show that all absorption peaks of functional groups and chemical bonds of stearic acid still exist, which suggests that these crystal materials composed of stearic acid and Na{sub 2}PO{sub 4}.12H{sub 2}O have good phase change stability and chemical compatibility. Thus, disadvantages caused by the subcooling of Na{sub 2}PO{sub 4}.H{sub 2}O and the low specific heat capacity of stearic acid can be solved, it is speculated that complement each other on the basis of organic/inorganic characteristics in itself is carried out for these two component materials of ...
Magnetic fluids (MFs) with a similar narrow size distribution of the iron oxide core were stabilized with lauric acid (MF 1), oleate (MF 2) or, after dialysis in the presence of liposomes, with phospholipid molecules (MF 3 and MF 4, respectively). The hydrodynamic sizes of the MF 1 and MF 3 were half those found for MF 2 and MF 4. The MFs were exposed to inductive heating in an alternating magnetic field at a frequency of 200 kHz and a maximum magnetic field strength of 3.8 kA m{sup -1}. Specific absorption rates (SAR) of 294 {+-} 42 (MF 1), 214 {+-} 16 (MF 2), 297 {+-} 13 (MF 3) and 213 {+-} 6 W g{sup -1} Fe (MF 4) were obtained. The data for MF 2 and MF 4 were identical to those found for the commercially available ferucarbotran. The biomedical relevance of the phospholipid-coated MFs is briefly discussed.
A zirconium alloy comprising from 0.8 to 1.6wt% of Sn, from 0.17 to 0.25wt% of Fe, from 0.15 to 0.25wt% of Cr and from 0.01 to 0.08wt% of Ni and Si at a concentration of 120ppm or lower as an impurity and the balance of Zr is melted into cast pieces and then subjected to an #beta# annealing. It is controlled so as to satisfy Fe + Cr + Ni #<=# 0.52wt%. Then, rolling and annealing are applied so that the total heat injection amount #SIGMA#A_i to the materials is within a range of from 1 x 10"-"1"9 to 1 x 10"-"1"7. #SIGMA#A_i = #SIGMA#t_i #centre dot# exp(-Q/RT_i), in which t_i represents processing time (hour) at an ith heat treatment step after the #beta# annealing, T_i represents a processing temperature (K) in the step i. Q represents an activating energy, R represents a gas constant, and Q/R 40,000. (I.N.).
We present results from an investigation of the dynamical behavior of buoyant magnetic flux rings in the radiative interior of a uniformly rotating early-type star. Our physical model describes a thin, axisymmetric, toroidal flux tube that is released from the outer boundary of the convective core, and is acted upon by buoyant, centrifugal, Coriolis, magnetic tension, and aerodynamic drag forces. We find that rings emitted in the equatorial plane can attain a stationary equilibrium state that is stable with respect to small displacements in radius, but is unstable when perturbed in the meridional direction. Rings emitted at other latitudes travel toward the surface along trajectories that largely parallel the rotation axis of the star. Over much of the ascent, the instantaneous rise speed is determined by the rate of heating by the absorption of radiation that diffuses into the tube from the external medium. Since the time scale for this ...
An outline of Manitoba Hydro's Earth Power program was presented. Details of the heat pump market in Manitoba were provided, including details of residential and commercial sales. Total residential heat pump sales amounted to 577 units in 2004, equivalent to over $11.2 million in sales. Commercial installations amounted to approximately $12.7 million. An outline of industry players was presented. The goals of Manitoba Hydro were outlined in relation to geothermal energy and the Power Smart program. Their objectives included increasing awareness of geothermal energy, making heat pumps more accessible, and improving industry infrastructure. Other objectives included educating the public about life-cycle cost implications, residential loans and commercial incentives. To date, the residential power loan has provided financing to over 300 Manitoba home owners for installations, with electrical savings of over 1.34 Gwh and ...
Earlier studies have indicated that xylitol may increase the absorption and urinary excretion of dietary oxalate. It has also been indicated that xylitol increases the absorption of calcium. Intestinal absorption of lead, a divalent contaminant in the diet, is in many respects similar to that of calcium. The purpose of this study was to evaluate the effects of xylitol on the intestinal absorption of lead using two different approaches: the in situ ligated intestinal loop technique in cockerels and gastric gavage in mice.
The Savannah River Swamp is a 3,020 Ha forested wetland on the floodplain of the Savannah River and is located on the Department of Energy`s Savannah River Site (SRS). Major impacts to the swamp hydrology occurred with the completion of the production reactors and one coal-fired powerhouse at the SRS in the early 1950`s. Water was pumped from the Savannah River, through secondary heatexchangers of the reactors, and discharged into three of the tributary streams that flow into the swamp. This continued from 1954 to 1988 at various levels. The sustained increases in water volume resulted in overflow of the original stream banks and the creation of additional floodplains. Accompanying this was considerable erosion of the original stream corridor and deposition of a deep silt layer on the newly formed delta. Heated water was discharged directly into Pen Branch and water temperature in the stream often exceeded 50 C. The nearly ...
In the nuclear power stations of GDR the rough radioactive waste includes borat-containing evaporator bottoms and spent ion exchanger resins. For its final disposal in deep geological formations (rock salt mines) this waste has to be solidified. The experience of one year lasting operation of a steam heated thin-film evaporator (heating surface 2 m{sup 3}) for evaporator bottoms to be solidified with a solid content of 200-250 g/l are reported on. In short time such amount of water is abstracted from the rough waste that due to the borate content a hot high-viscous product passes from evaporator to waste drum and there solidifies like glass to monolith. The product quality depends on the adjustment of the flow-equilibrium in the evaporator. Boric acid is used as matrix for the radioactive residues. The residual water content of the solidified waste product was about 15-20%, the volume reduction was V{sub f}=5...6. In order ...
In the nuclear power stations of GDR the rough radioactive waste includes borat-containing evaporator bottoms and spent ion exchanger resins. For its final disposal in deep geological formations (rock salt mines) this waste has to be solidified. The experience of one year lasting operation of a steam heated thin-film evaporator (heating surface 2 m"3) for evaporator bottoms to be solidified with a solid content of 200-250 g/l are reported on. In short time such amount of water is abstracted from the rough waste that due to the borate content a hot high-viscous product passes from evaporator to waste drum and there solidifies like glass to monolith. The product quality depends on the adjustment of the flow-equilibrium in the evaporator. Boric acid is used as matrix for the radioactive residues. The residual water content of the solidified waste product was about 15-20%, the volume reduction was V_f=5...6. In order to be sure ...
A new performance model of the externally fired combined cycle (EFCC) is implemented in ASPEN (Advanced System for Process ENgineering), a chemical process simulator. The model accounts for interactions within and between approximately a dozen major process areas. The new model is applied to case studies to evaluate the sensitivity of process performance to the ranges of uncertainty in key model inputs such as heat losses, carbon conversion, and air leakage rates, and to illustrate how alternative designs, including steam injection and flue gas desulfurization (FGD), can affect plant thermal efficiency and net power output. The model results suggest that careful attention to the design of the FGD system is needed, especially with respect to reheat, and that steam injection may offer cost savings associated with reducing the size of the steam turbine with little or no penalty on plant output or plant efficiency. Uncertainties in the slagging combustor and the ...
DC resistivity, dc magnetization, and specific heat of eight Sc{sub 5}Co{sub 4}Ge{sub 10}-type crystal-structure compounds R{sub 5}T{sub 4}Ge{sub 10} for R = Dy, Ho, Er, Tm, and T = Rh and Ir are presented. The resistivity, single-crystal magnetization, and specific-heat results show that in all those compounds, the magnetic moments order antiferromagnetically in the c direction at low temperature. However, in the Er and Tm compounds, the magnetizations along x-y hard directions do not show any anomalies above 2.0 K. This suggests that the ordered Er and Tm ions, which have positive quadrupole coefficients, interact with a crystal field that has an electronic potential valley along the c axis. The fitting of the hard axis magnetizations to Curie-Weiss law suggests that the resulting antiferromagnetic-like {theta} reflects the strength of the crystal-field torque on the magnetic moments rather than the strength of antiferromagnetic ...
DC resistivity, dc magnetization, and specific heat of eight Sc/sub 5/Co/sub 4/Ge/sub 10/-type crystal structure compounds R/sub 5/T/sub 4/Ge/sub 10/ for R = Dy, Ho, Er, Tm, and T = Rh and Ir are presented. The resistivity, single crystal magnetization, and specific heat results show that in all those compounds, the magnetic moments order antiferromagnetically in the c direction at low temperature. However, in the Er and Tm compounds, the magnetizations along x-y hard directions do not show any anomalies above 2.0 K. This suggests that the ordered Er and Tm ions, which have positive quadrupole coefficients ..cap alpha../sub j/, interact with a crystal field that has an electronic potential valley along the c axis. The fitting of the hard axis magnetizations to Curie-Weiss law suggests that the resulting antiferromagnetic-like theta reflects the strength of the crystal field torque on the magnetic moments rather than the strength of ...
Metallic components within or immediately adjacent to gasifiers, such as gas distributors, thermowells, transfer lines, and cyclones, are subjected to severe of temperature, pressure, and hostile multicomponent gas environments. Metallic heatexchangers/waste-heat boilers resistant to sulfidation, corrosion. and erosion in low- and medium-Btu gas environments are essential components in large-scale gasification schemes, in both dry ash and slogging type gasifiers. Components, in general. must be resistant to corrosion, erosion, and high-temperature creep. A substantial data base is needed on the mechanical properties of materials exposed to complex gas environments to provide a more viable basis for establishing long-term reliability of components. This work examines high-temperature creep of Alloy 800, a high-chromium alloy widely used in coal conversion systems, after exposure to oxygen and oxygen/sulfur mixed-gas environments over a wide ...
Scaling criteria for a natural-circulation loop are examined. The present state of knowledge of scaling to obtain similarity during single- and two-phase flow conditions in a closed loop are reviewed, and an alternative development of two-phase similarity parameters is presented. The loop scaling criteria are the results of analyses in which flow from one component to another is considered. In this work, boundary conditions for the closed loop are developed to obtain scaling criteria for leak flow, injection flow, and heat loss to ambient. The leak scaling criteria are specialized for modeling approaches using prototypic fluid at prototypic or reduced pressures. The derived scaling parameters are examined for their application to two existing scaled test facilities: the Multi-Loop Integral System Test (MIST) facility at Babcock and Wilcox, and the UMCP 2 x 4 facility at the University of Maryland College Park. The heat loss similarity analysis ...
Heat transfer through the gas diffusion layer (GDL) is a key process in the design and operation of a PEM fuel cell. The analysis of this process requires determination of the effective thermal conductivity as well as the thermal contact resistance associated with the interface between the GDL and adjacent surfaces/layers. In the present study, a custom-made test bed that allows the separation of effective thermal conductivity and thermal contact resistance in GDLs under vacuum and ambient conditions is described. Measurements under varying compressive loads are performed using Toray carbon paper samples with a porosity of 78% for a range of thicknesses. The measurements are complemented by compact analytical models that achieve good agreement with experimental data. A key finding is that thermal contact resistance is the dominant component of the total thermal resistance; neglecting this phenomenon may result in significant errors in evaluating ...
The thermal performance monitoring and optimization system TEMPO is developed at the OECD Halden Reactor Project. The system supports staff of nuclear power plants in identification and correction of problems, which cause small decreases in plant efficiency but which may lead to significant economical losses. The system-wide physical model consists of mathematical description of individual components, such as the reactor, the pumps, the heatexchangers, or the turbines, etc. TEMPO code has recently been extended with new steam generator (SG) models. The present paper summarizes the thermal-hydraulic modelling aspects of the vertical and the horizontal SG. The heat balance equations and their solution are shown with the appropriate initial and boundary conditions. The method of the calculation of the pressure losses are also introduced. The vertical SG model is based on a U-tube structure and treated as a 1D flow channel. ...
Research is in progress to obtain a satisfactory creep ductility for alloy 800 when used as heatexchanger material in sodium-cooled fast reactors (LMFBR). The creep test characteristics at present available show that a pronounced tendency to reduced elongation by creep failure may arise after prolonged testing in the 500-700 deg C temperature range. This phenomenon is now agreed to be primarily inherent to the conditions for Ni_3(Ti,Al) precipitation in the material and hence to the Ti and Al concentrations. By structural studies and hardness measurements on material subjected to creep tests and taken from a large number of castings, the relationship was established between the (Ti+Al) content and the structural hardness effect of Ni_3(Ti,Al) at 600 deg C. Below a certain Ti+Al concentration, no precipitation occurs and hence the creep ductility to failure can be improved considerably by limiting the allowed Ti+Al content in the material, ...
A number of binary geothermal cycles utilizing mixed hydrocarbon working fluids were analyzed with the overall objective of finding a working fluid which can produce low-cost electrical energy using a moderately-low temperature geothermal resource. Both boiling and supercritical shell-and-tube cycles were considered. The performance of a dual-boiling isobutane cycle supplied by a 280/sup 0/F hydrothermal resource (corresponding to the 5 MW pilot plant at the Raft River site in Idaho) was selected as a reference. To investigate the effect of resource temperature on the choice of working fluid, several analyses were conducted for a 360/sup 0/F hydrothermal resource, which is representative of the Heber resource in California. The hydrocarbon working fluids analyzed included methane, ethane, propane, isobutane, isopentane, hexane, heptane, and mixtures of those pure hydrocarbons. For comparison, two fluorocarbon refrigerants were also analyzed. These fluorocarbons, R-115 and R-22, were ...
This paper contains literature from American Power Conference Air Toxics Being Measured Accurately, Controlled Effectively NO{sub x} and SO{sub 2} Emissions Reduced; Surface Condensers Improve Heat Rate; Usable Fuel from Municipal Solid Waste; Cofiring Technology Reduces Gas Turbine Emissions; Trainable, Rugged Microsensor Identifies of Gases; High-Tc Superconductors Fabricated; High-Temperature Superconducting Current Leads; Vitrification of Low-Level Radioactive and Mixed Wastes; Characterization, Demolition, and Disposal of Contaminated Structures; On-Line Plant Diagnostics and Management; Sulfide Ceramic Materials for Improved Batteries; Flywheel Provides Efficient Energy Storage; Battery Systems for Electric Vehicles; Polymer-Electrolyte Fuel Cells for Transportation; Solid-Oxide Fuel Cells for Transportation; Surface Acoustic Wave Sensor Monitors Emissions in Real-Time; Advance Alternative-Fueled Automotive Technologies; Thermal & Mechanical Process; ...
The Externally-Fired Combined Cycle (EFCC) offers a method for operating high-efficiency gas and steam turbine combined cycles on coal. In the EFCC, an air heater replaces the gas turbine combustor so that the turbine can be indirectly fired. Ceramic materials are required for the heatexchange surfaces to accommodate the operating temperatures of modern gas turbines. The ceramic air heater or heatexchanger is the focus of this program, and the two primary objectives are (1) to demonstrate that a ceramic air heater can be reliably pressurized to a level of 225 psia (1.5 MPa); and (2) to show that the air heater can withstand exposure to the products of coal combustion at elevated temperatures. By replacing the gas turbine combustor with a ceramic air heater, the cycle can use coal or other ash-bearing fuels. Numerous programs have attempted to fuel high efficiency gas turbines directly with coal, often ...
The Externally-Fired Combined Cycle (EFCC) offers a method for operating high-efficiency gas and steam turbine combined cycles on coal. In the EFCC, an air heater replaces the gas turbine combustor so that the turbine can be indirectly fired. Ceramic materials are required for the heatexchange surfaces to accommodate the operating temperatures of modern gas turbines. The ceramic air heater or heatexchanger is the focus of this program, and the two primary objectives are (1) to demonstrate that a ceramic air heater can be reliably pressurized to a level of 225 psia (1.5 MPa); and (2) to show that the air heater can withstand exposure to the products of coal combustion at elevated temperatures. By replacing the gas turbine combustor with a ceramic air heater, the cycle can use coal or other ash-bearing fuels. Numerous programs have attempted to fuel high efficiency gas turbines directly with coal, often ...
Calcium and phosphorus were mainly responsible for reducing the gastrointestinal absorption of lead in human subjects. The effect of calcium was greater than phosphorus, and their combined effect was more than additive. Increasing weights of calcium and phosphorus progressively reduced lead absorption. The relationship between absorption and increasing weights could be described by two negative exponentials. These effects could be explained if lead competed with calcium and phosphorus for common transport mechanisms in the gut. Milk was also found to reduce lead absorption. Adding milk to the diet of people with low dietary calcium intake could reduce the possibility of increased absorption of ingested lead.
This report documents the Proceedings of the 1997 Oil Heat Technology Conference and Workshop, held on April 3--4 at Brookhaven National Laboratory (BNL), and sponsored by the US Department of Energy--Office of Building Technologies, State and Community programs (DOE-BTS), in cooperation with the Petroleum Marketers Association of America (PMAA). This Conference is a key technology transfer activity supported by the ongoing Combustion Equipment Technology (Oil-Heat R and D) program at BNL, and is aimed at providing a forum for the exchange of information among international researchers, engineers, manufacturers, and marketers of oil-fired space-conditioning equipment. The objectives of the Conference were to: identify and evaluate the state-of-the-art and recommend new initiatives for higher efficiency, a cleaner environment, and to satisfy consumer needs cost-effectively, reliably, and safely: and foster cooperation among ...
Trinitrotoluene (TNT) absorption was assessed in groups of workers at two explosives factories by measuring the urinary concentrations of dinitroaminotoluene (DNAT) metabolites. DNAT was detected in...Full Text Available
The possibility of gamma-absorption identification of the analyzed substance is considered. the basic provisions of the proposed method are concentrated on the example of carbohydrates and hydrocarbons. The above method is tested experimentally on polyethylenes and polystyrene
The term 'Post-CHF' was generally used in the two-phase flow regime in tube flow occurring downstream of the CHF. It has various other names such as dispersed flow, liquid-deficient flow, mist flow and film boiling because the two-phase regime is characterized by a continuous vapor phase with discrete liquid drops and a non-wetted heated surface. The regime has been adopted in a lot of applications including nuclear power plants, fossil power plants, steam generators, refrigeration systems and spray cooling, In particular, this regime has a considerable importance in the areas of light water reactor(LWR) accident analysis (off-normal operating conditions) and design in heatexchangers operating in the once-through mode where subcooled liquid enters the exchanger and superheated vapor exits. Recently, innovative PWRs adopt very high power density increases and so require increased ...
The term 'Post-CHF' was generally used in the two-phase flow regime in tube flow occurring downstream of the CHF. It has various other names such as dispersed flow, liquid-deficient flow, mist flow and film boiling because the two-phase regime is characterized by a continuous vapor phase with discrete liquid drops and a non-wetted heated surface. The regime has been adopted in a lot of applications including nuclear power plants, fossil power plants, steam generators, refrigeration systems and spray cooling, In particular, this regime has a considerable importance in the areas of light water reactor(LWR) accident analysis (off-normal operating conditions) and design in heatexchangers operating in the once-through mode where subcooled liquid enters the exchanger and superheated vapor exits. Recently, innovative PWRs adopt very high power density increases and so require increased safety margins. For ...
... Reduce partner costs, save time, and overcome delays in data transmission. Data Exchanges States are currently submitting data to each other and to the EPA in the exchanges listed below. Data Exchanges are typically referred to by their acronyms, which are listed below. To find out more about EPA data exchanges, please follow the links to EPA Web sites. AQS - Air Quality Sub-system (...
The extent of exchange rate pass-through has been playing an increasingly pivotal role in the transmission of exchange rate shocks and adequate policy responses. We develop a model of exchange rate pass-through that allows the stochastic process of exchange rate to include the lagged values of the velocity of money. We show that the likelihood and extent of pass-through is sensitive to the lagged response.
A new analysis is presented which links real volume fractions, relaxation rates, and intracompartmental exchange rates directly with apparent volume fractions and relaxation rates obtained from biexponential...Full Text Available
The chloromethylation reaction of an asphaltite and styrene graft copolymer followed by the amination of the chloromethylated products was optimized. New strongly basic anion exchangers with an exchange capacity of 2.5 mg-equiv/g and a mechanical strength of 93% were prepared.
...standards and implementation specifications for exchanging electronic health information. 170.205 Section 170.205 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES HEALTH INFORMATION TECHNOLOGY HEALTH INFORMATION TECHNOLOGY...
Investigated here were the effects of microwave (MW) radiation (2450-MHz, continuous-wave, mean specific absorption rate of 103.5 + or - 4.2 W/kg) and convention heating on the nonphosphorylating oxidative metabolism of human peripheral mononuclear leukocytes (96% lymphocytes, 4% monocytes) at 37 C. Metabolic activity, determined by chemiluminescence (CL) of cells challenged with luminol (5-aminO-2, 3-dihydro-1, 4-phthalazinedione) linked to bovine serum albumin, was detected with a brightness photomer. A significant stimulation after after MW exposure (p < 0.005) over total CL of matched 37 C-incubator controls was observed. A similar degree of stimulation, compared to incubator controls, was also detected after sham treatment. No significant difference existed between changes in total CL or stimulation indices of the MW and sham-exposed groups. Exposure to MW radiation, under normothermic (37 + or - 0.03 C) conditions, appears to have no ...
The MTX explored the plasma heating effects of 140 GHz microwaves from both Gyrotrons and from the IMP FEL wiggler. The Gyrotron was long pulse length (0.5 seconds maximum) and the FEL produced short-pulse length, high-peak power, single and burst modes of 140 GHZ microwaves. Full-power operations of the IMP FEL wiggler were commenced in April of 1992 and continued into October of 1992. The Experimental Test Accelerator H (ETA-II) provided a 50-nanosecond, 6-MeV, 2--3 kAmp electron beam that was introduced co-linear into the IMP FEL with a 140 GHz Gyrotron master oscillator (MO). The FEL was able to amplify the MO signal from approximately 7 kW to peaks consistently in the range of 1--2 GW. This microwave pulse was transmitted into the MTX and allowed the exploration of the linear and non-linear effects of short pulse, intense power in the MTX plasma. Single pulses were used to explore and gain operating experience in the parameter space of the IMP FEL, and finally ...
A method for enrichment of the ppb level of cadmium in water by using the coagulation of soybean protein by adding acids or its complex-forming character with heavy metal ions was investigated. After adding fixed amounts of soybean milk and 2% sodium diethyldithiocarbamate(DDTC) aqueous solution and a suitable amount of delta-gluconic lactone (delta-GL) to a sample solution, the mixture was heated to boiling in order to coagulate the protein. The coagulum(soybean curd) was separated from the suspension by centrifugation and burned to ashes with a low temperature plasma asher. Then the cadmium enriched in it was determined by atomic absorption spectrometry. Various factors such as the pH of the sample solution, the amounts of soybean milk and the collection additives, and the concentration of NaCl in the sample solution on the recovery of cadmium were examined systematically. The best recovery was obtained under the following conditions: To a ...
Ellipsometric studies and reflectance measurements on five anodized coloured 304 stainless steel samples (Brown, Violet, Blue, Light Grey and Dark Grey) are reported. The optical properties, solar absorptance and thermal emittance of samples have been obtained. Measured values of absorptance lay between 0.75-0.87 together with a near normal emittance value approx. =0.10 at 100/sup 0/C. The total hemispherical emittance has been measured at 100 and 200/sup 0/C for the sample having the best selective surface. This study shows that the blue coloured surface has the most favourable combination of radiation properties. The surface deteriorates at temperatures above 210/sup 0/C. Oxidation is assumed to be the deterioration mechanism. The different samples exhibited difference in the /PSI/ and ..delta.. parameters as determined by ellipsometry both before and after heat treatments. When brown and violet samples were coated with a ...
We examined a catalytic effect of niobium oxide (Nb{sub 2}O{sub 5}) on the hydrogen storage properties of MgH{sub 2} prepared by mechanical ball milling method. The MgH{sub 2} composite doped with 1 mol% Nb{sub 2}O{sub 5} by ball milling for 20 h desorbed hydrogen up to {approx}6 mass% in the temperature range from 200 to 250 {sup o}C at the heating rate of 5 {sup o}C/min under a purified helium flow. After dehydrogenation at 200 {sup o}C, the product showed remarkable hydrogen absorption kinetics. A large amount of gaseous hydrogen up to {approx}4.5 mass% was absorbed even at room temperature under 1 MPa hydrogen pressure within 15 s and finally its capacity reached up to 5 mass%. Furthermore, the valence state of Nb{sub 2}O{sub 5} doped in MgH{sub 2} was examined by X-ray absorption near edge structure (XANES) measurement. The results indicated that additive Nb{sub 2}O{sub 5} was reduced by MgH{sub 2} during mechanical ...
Carbon-14 was analysed by direct absorption of carbon dioxide on the mixture of organic amine compound and scintillation cocktail then counted by low level liquid scintillation counter. This method can be applied for radiocarbon dating. In this study, the effects of carbon dioxide absorption, and counting efficiency were investigated using various commercial available cocktail. It was found that permafluor V and Ready Gel showed the highest carbon dioxide absorption whereas the Permafluor V showed the highest counting efficiency
Although clinic environments are a primary location for exchanging information with clinicians, patients experience these spaces as harsh environments to access, use, exchange, and manage information....Full Text Available
The oxygen production of a photosynthetic gas exchanger containing Chlorella pyrenoidosa (1% packed cell volume) was measured when various concentrations of carbon dioxide were present...Full Text Available
The study was directed towards determining the usability of clay and fine wastes (CW and FW) of boron from the concentrator plant in Kirka (Turkey) as a fluxing agent in production of red mud (RM) brick. Both laboratory studies on the characterization of materials and industrial-scale tests for production of bricks were carried out. CW and FW, which have similar chemical composition but include different types and amounts of oxides, were added in amounts of 5, 10 and 15wt% to RM, which consists of high amounts of Fe{sub 2}O{sub 3}, Al{sub 2}O{sub 3}, SiO{sub 2} and alkalies. Six different sets of samples have been produced and fired at 700, 800 and 900{sup o}C. Dry shrinkage of green body, bending and compressive strength, firing shrinkage, water absorption, frost resistance and harmful magnesia and lime tests on heat-treated bodies have been performed. The mineralogical and mechanical tests showed that usability of boron wastes as a fluxing ...
In this study, WO{sub 3} thin films were grown on glass substrates using an aqueous solution containing tungstate (NH{sub 4}){sub 2}WO{sub 4} as precursor. The substrate temperature incremented from 250 to 500 deg. C, by steps of 50 deg. C. The structural properties were investigated using XRD, atomic force microscopy and scanning electronic microscopy techniques. Microprobe analyses showed that a balanced stoichiometric composition was obtained for thin films prepared at T{sub s} = 350 and 400 deg. C. The X-ray diffraction analyses showed different structure crystallography in function of the substrate temperature. Moreover, films deposited at 400 deg. C were annealed in air for 2 h at 450 and 500 deg. C, respectively and the structural changes due to heat treatment were studied. Finally, the optical properties of these films were carried out using optical measurements of transmittance T({lambda}) and reflectance R({lambda}) spectra in 300-1800 nm domain. The ...
In this study, WO3 thin films were grown on glass substrates using an aqueous solution containing tungstate (NH4)2WO4 as precursor. The substrate temperature incremented from 250 to 500 deg. C, by steps of 50 deg. C. The structural properties were investigated using XRD, atomic force microscopy and scanning electronic microscopy techniques. Microprobe analyses showed that a balanced stoichiometric composition was obtained for thin films prepared at Ts = 350 and 400 deg. C. The X-ray diffraction analyses showed different structure crystallography in function of the substrate temperature. Moreover, films deposited at 400 deg. C were annealed in air for 2 h at 450 and 500 deg. C, respectively and the structural changes due to heat treatment were studied. Finally, the optical properties of these films were carried out using optical measurements of transmittance T(?) and reflectance R(?) spectra in 300-1800 nm domain. The refractive and absorption ...
During the last 15 years cycles with CO{sub 2} capture have been in focus, due to the growing concern over our climate. Often, a natural gas fired combined cycle with a chemical absorption plant for CO{sub 2} capture from the flue gases have been used as a reference in comparisons between cycles. Neither the integration of the steam production for regeneration of amines in the combined cycle nor the off-design behaviour of such a plant has been extensively studied before. In this paper, the integration of steam production for regeneration of the amines is modelled at design load and studied in off-design conditions for a combined cycle. Different ambient conditions and part-load strategies and their influence on the cycle performance are also examined. Of particular interest is a novel strategy with the possibility of longer life of gas turbine blading, with marginal loss in efficiency. The off-design performance of the combined cycle is modelled in a rigorous way ...
The industrial policy of fine ceramics which is one of the new material expected to solve energy/environmental problem, is described. Fine ceramics are possessed with the characteristics like surpassing electromagnetic properties, heat resistance, high strength, etc. and its use as highly efficient power generation plant material, functional material for various sensors/electronic, and activation of existing industries are cited. As for the reclamation of global environment, promotion of saving energy in a global scale, development of innovative environmental technology and increase of carbon dioxide absorption source are described. Furthermore, research and development work in Japan on global environmental industrial technology for 1992 to 1993, new sunshine project and technical developments relating to fine ceramics are explained. As for the results of research and development, the results from the case study of 300kw type gas turbine are ...
The structural, morphological and optical properties of vacuum-evaporated CdTe thin films were investigated as a function of substrate temperature and post-deposition annealing without and with CdCl2/treatment at 400 C for 30 min. Diffraction patterns are almost the same exhibiting higher preferential orientation corresponding to (111) plane of the cubic phase. The intensity of the (111) peak increased with the CdCl2/annealing treatment. The microstructure observed for all films following the CdCl2/annealing treatment are granular, regardless of the as-deposited microstructure. The grain sizes are increased after the CdCl2/annealing treatment but now contain voids around the grain boundaries. The optical band gaps, Eg, were found to be 1.50, 1.50 and 1.48 eV for films deposited at 200 K and annealed without and with CdCl2/treatment at 400 C for 30 min respectively. A progressive sharpening of the absorption edge upon heat treatment particularly ...
We have investigated CeTSi{sub 3} and CeTGe{sub 3} (T = Rh and Ir) by measuring the magnetic susceptibility, specific heat, electrical resistivity, the resonant inverse photoemission (RIPES) and M{sub IV,V} x-ray absorption spectra (XAS). The germanides showed a very weak Kondo effect, but the silicides exhibited a negatively large Weiss temperature (approx. = -130 K) and a lnT dependence of magnetic resistivity above 100 K, suggesting that they are a Kondo-lattice compound with a high Kondo temperature T{sub K} (approx. = 100 K). The Curie-Weiss law suggests that Ce atoms in these compounds remain close to 3+ down to about 150 K in spite of their high T{sub K}. In general, both RIPES and M{sub IV,V} XAS support their apparently stable valency. (author)
Cooling towers of power plants are used to dissipate waste heat into the atmosphere. If saline water is used for cooling, a saline aerosol known as drift is released into the atmosphere. Drift effects on vegetation are not well known. To simulate drift for a field study, cooling tower basin water was sprayed thirty separate times during a 46-day period in 1975 on Virginia pine (Pinus virginiana), flowering dogwood (Cornus florida), tulip tree (Liriodendron tulipfera), and California privet (Ligustrum ovalifolium), Norway spruce (Picea abies), and white ash (Fraxinus americana) were added in 1976 and all trees were sprayed 43 times during a 59-day period. Only dogwood leaves showed significant injury. Absence of injury on other species was probably due to the ability of their leaves to exclude, or reduce absorption of, toxic concentrations of the ions supplied.
This work reports studies of ethanol oxidation on Pt-Sn/C catalysts with nearly the same particle size and identical overall composition having different amounts of oxide and alloyed phases. Results of characterization of physical properties by transmission electron microscopy (TEM), X-ray diffraction (XRD), differential scanning calorimetry (DSC), X-ray photoelectron spectroscopy (XPS), and in situ dispersive X-ray absorption spectroscopy (DXAS) are presented. The variation in the amount of oxide and alloyed phases, promoted by heat treatments in mild temperature conditions, does not produce any significant particle growth. Cyclic voltammetry and oxidation of adsorbed CO in acid medium are used to probe the surface conditions. Data on the electrocatalytic activity towards ethanol oxidation, obtained by potential sweeps and chronoamperometry, are discussed and correlate well with the physical properties. This study, carried out in the absence ...
The chemistries of reactants, plasticizers, solvents and additives in an epoxy paint are discussed. Polyamide additives may play an important role in the absorption of molecular iodine by epoxy paints. It is recommended that the unsaturation of the polyamide additive in the epoxy cure be determined. Experimental studies of water absorption by epoxy resins are discussed. These studies show that absorption can disrupt hydrogen bonds among segments of the polymers and cause swelling of the polymer. The water absorption increases the diffusion coefficient of water within the polymer. Permanent damage to the polymer can result if water causes hydrolysis of ether linkages. Water desorption studies are recommended to ascertain how water absorption affects epoxy paint.
Absorption of ''organically bound'' "2"3"3U and "2"4"1Am from gastrointestinal tracts of adult rats was twice that of the inorganic nitrate form. There was no difference between transport of "2"3"2U and "2"3"3U by adult rats, but "2"3"2U absorption by newborn rats was four times that of "2"3"3U. Absorption of "2"3"8Pu nitrate through the gut of the newborn is relatively insensitive to dose but incorporation in the gut mucosa saturates at high dose levels. Absorption of "2"3"8Pu is greater at 4 hr of age than at 24 hr.
Studies of the gastrointestinal absorption of lead-203 chloride were carried out on 11 normal subjects, 7 males and 4 females. Whole body counting of these subjects after administration of 74 kBq (2 #mu#Ci) of cyclotron-produced lead-203 chloride showed a mean absorption of 21.3% of the dose with a range from 10.4 to 47.7%. The male subjects had a lower mean absorption of 18.1% of the dose compared with a mean of 26.9% in the females. Although this difference did not reach statistical significance, it is postulated that male/female differences in absorption may relate to differences in iron saturation of the subjects.
The European Union (EU) market integration is leading to increasingly monopolistic electricity market infrastructures, which has opened a debate on the regulation of these so-called power exchanges. In this paper, we start by stating that there are two types of power exchanges in Europe, i.e. 'merchant' and 'cost-of-service regulated' power exchanges. We then discuss how regulation can be used to better align their incentives with the main power exchange tasks. We conclude that adopting the cost-of-service regulated model for all power exchanges in Europe could be counterproductive in the current context, but that regulation can help ensure that the benefits of the EU market integration materialize. Promising regulatory actions include tempering the reinforced market power of power exchanges, and quality-of-service regulation for the ongoing cooperation among ...
The aim of the study is to prepare ionic exchangers using the polymerization of unsaturated polyster with monomeric styrene units in a ratio of 60%: 40% respectively. The type of method involved in this preparation, is called An Emulsion Polymerization. Such type of polymerization was carried out by two techniques: chemical and irradiation techniques. The first techniques requires the formation of free radical monomers by use of methyl Ethy Ketone Peroxide capable of decomposing into free radicals upon heating, while the other technique involves the use of gamma rays (using Co-60 source) capable of activating monomers towards free radical formations. A number of very effective chemical parameters and physical factors were used and investigated throughout the reactions such as: dispersant matrix, viscosity, rate of mixing, and irradiation dose. Besides, the study has included the study of the rate of Resin Beads Swelling which is thought to be ...
The transmutation of minor actinides in-reactor is one solution currently being studied for the long time management of nuclear waste. In the heterogeneous concept the radionuclides are incorporating in an inert ceramic matrix. The support material must be insensitive to radiation damage. Fission product damage is the main radiation damage source during the transmutation process and therefore it is of the utmost importance to study their effects. We irradiated spinels MgAl_2O_4 (matrix of reference) and ZnAl_2O_4 by fast ions (by example: (86)Kr of approximately 400 MeV) simulating the fission products. Under these conditions, the damage is primarily due to the electronic energy losses (Se). One of the structural features of spinel AB_2O_4 is that the two cations (A(2+) and B(3+)) can exchange their site. This phenomenon is quantified by the inversion parameter. We highlight by XRD in grazing incidence that the structural changes observed in MgAl_2O_4 correspond to ...
The Argonne Boundary Layer Experiments (ABLE) facility, located in south central Kansas, east of Wichita, is devoted primarily to investigations of and within the planetary boundary layer (PBL), including the dynamics of the mixed layer during both day and night; effects of varying land use and land form; the interactive role of precipitation, runoff, and soil moisture; storm development; and energy budgets on scales of 10 to 100 km. Located entirely within the Walnut River watershed, ABLE provides intense measurements within the northeast quadrant (Fig. 1) of the Southern Great Plains (SGP) Cloud and Radiation Testbed (CART) of the Atmospheric Radiation Measurement (ARM) Program (Stokes and Schwarz, 1994). By combining the continuous measurements of ABLE with ancillary continuous measurements of, for example, the ARM and the Global Energy Water cycle Experiment (GEWEX) (Kinster and Shukla, 1990) programs, ABLE provides a platform within which shorter, more intensive studies, such as ...
The objective of this contract is to design and build a small, lightweight, stand-alone thermophotovoltaic electric generator, capable of at least 100 Watts useful output for charging 24V batteries. The prototype generator built consists of a pre-mixed burner, a cylindrical selective emitter mantle surrounded by six silicon photovoltaic concentrator arrays. The arrays are cooled with forced-air heatexchangers using self-powered fans. The generator, operated at 117,00 W (40,000 BTU/hr) of fuel input rate, produces 122 W of electrical power at 1.0% of efficiency. The cooling and pre-mix fans consume 35 W of electrical power resulting in a net 85 Watts of electrical output for charging batteries. The generator`s output is capable of continuous charging five 12/24V batteries over 10 hours with a 9.07 Kg (20 lbs.) of propane gas.
In the context of the research project, the physical basis of the direct decoupling of highly concentrated solar radiation in materials without the detour via absorbing heatexchanger walls was examined. Also, the first chemical processes suitable for the effective long-term storage of solar energy were analysed, relevant experiments were carried out and the necessary receiver techniques for high temperature applications were provided. The principle of direct coupling was examined on fluidized beds on the one hand and on cavity receivers, on the other hand. The contribution shows the results achieved in detail. It is recorded that first processes for storing solar energy in chemical reactions were able to be examined. Alkaline earth hydroxides accommodated in ceramic honeycomb structures seem to be possible as stores for medium temperature ranges around 500deg C. Investigations on receiver structure materials are also making progress. Highly ...
Very High Temperature gas cooled nuclear Reactor (VHTR), which was coupled with Sulfur-Iodine (SI) thermo-chemical cycle, has been selected for the Nuclear Hydrogen Development and Demonstration (NHDD) project in Korea Atomic Energy Research Institute. Among the various hydrogen production methods, Sulfur-Iodine (SI) thermo-chemical cycle is a good method as a massive hydrogen production without CO2 emission. In SI cycle, the sulfuric acid decomposition is one issue for the material corrosion on high temperature and pressure condition. For the simulation of the sulfuric acid decomposition, we designed a sulfuric acid loop with a small-scale gas loop which is simulated for the integrity and feasibility tests on a H2SO4 decomposition process. The primary objective of the loop is to validate the corrosion and the mechanical performances of a key component of the NHDD, Process HeatExchanger (PHE). In this paper, we discussed the preliminary ...
An experimental campaign, aiming to investigate the perturbation effects induced by fixed obstacles on turbulence measurements in airflows at the air-sea interface, was carried out at the marine platform of the Italian Navy, located in the harbour of La Spezia (North Ligurian Sea, Italy) on 28., 29., and 30. June 1994. This study was prompted by the ever-growing interest in more reliable estimates of energy, mass, and momentum exchanges between water surfaces and atmosphere, whose measurements are severely limited by the geometrical constraints of floating or fixed platforms where they are installed. Two types of meteorological instruments have been used: fast response (20 and 21 Hz) ultrasonic anemometers and fluxmeters to measure turbulent momentum, sensible, and latent heat fluxes and slow-response sensors (less than 4 Hz and sampled at a rate of 10{sup 2} Hz) to measure average wind and temperature vertical profiles in the perturbed ...
The metal dependence of mesoporous activated carbons with various metal acetylacetonate (acac) particles prepared from Morwell coal was studied. In experiment, the mixture of Morwell coal and acac metal complexes were dissipated into tetrahydrofuran, and after agitation in Ar atmosphere, the solvent was removed by vacuum distillation. Coal specimens with Fe(acac)3, Ni(acac)2 and Co(acac)2 as acac complexes were activated by exchanging flow gas with water vapor after heat treatment in N2 gas flow at 900{degree}C. The pore sizes of the specimens were obtained from N2 adsorption isotherms by BET method and BJH method. Conditions of pores and metals in the specimens were examined by XRD measurement and TEM observation. The relation between the above conditions and pore characteristics obtained from adsorption experiment was also examined. As a result, the difference in mesopore ratio between the specimens and blank specimens was larger in the order ...
With regard to a fracture system in the Hijiori hot dry rock artificial reservoir, an attempt was made on an interpretation which integrates different data. Major factors that characterize development and performance of an artificial reservoir are composed of a fracture system in rocks, which acts as circulating water paths, a heatexchange face and a reservoir space. The system relates not only with crack density distribution, but also with cracks activated by water pressure fracturing, cracks generating acoustic emission (AE), and cracks working as major flow paths, all of which are characterized by having respective behaviors and roles. Characteristics are shown on AE cluster distribution, crack distribution, production zone and estimated stress fields. Mutual relationship among these elements was discussed based on the Coulomb`s theory. The most important paths are characterized by distribution of slippery cracks. Directions and appearance ...
A large amount of industrial water is used for cooling the various process fluids in the petroleum purification factories as well as petroleum chemistry factories. Consequently, a lot of heatexchangers as the necessary constitutional instruments are made of carbon steel. Due to the most of the corrosions of the carbon steel occurring in such cooling water systems are pitting corrosions, the inhibition thereof is extremely important for the elongation of the life of the plants and the stable operation. In this paper, the influences of water quality fractions on pitting corrosion of carbon steel in cooling water circumstance are examined aiming at the fouling in the cooling water. The fouling in the cooling water does not only increase the amount of occurrence of pitting corrosion but also accelerates the progress of pitting corrosion enlarging the rust due to its deposition near the anode. Since only the inhibitor is not sufficient to inhibit ...
Advanced coal-fired combined-cycle power systems under development and demonstration have the potential to increase generating efficiency to approach 50%, reduce the cost of electricity by up to 20%, and meet stringent standards on emissions of SO{sub x}, NO{sub x}, fine particulates, and air toxic metals. Integrated gasification combined cycle, pressurized fluidized-bed combustion, and externally fired combined cycle systems rely on different high-temperature combinations of heatexchange, gas filtration, and sulfur capture to meet these requirements. The success of these systems when operated on low-rank coals depends importantly on the behavior of the ash. This paper focuses on the behavior of ash in an intermediate-scale transport gasifier coupled with a hot-gas cleanup system. The work reported is part of the overall program on hot-gas cleanup and the transport reactor development unit (TRDU) located at the Energy and Environmental ...
The goal of GRI's Gas Appliance Technology Center is to encourage the introduction of highly efficient, cost-effective, convenient gas appliances for residential and commercial gas users. The report covers activity at Battelle from February 1989 to April 1990 in broad support tasks, residential and commercial appliances, and residential space conditioning. Broad support tasks included the G/A/S Newsletter; the GATC InfoBase; and technology transfer, workshops, and GATC coordination. Residential appliance tasks included burner technology research, gas appliance venting, gas lighting, and plastics durability. Commercial appliance tasks included development of a commercial cooktop fuel/air mixing valve. Residential space conditioning tasks included a corrosion test method for gas appliances and vents, generic technology for condensing heatexchangers, and technology for self-powered appliances. These tasks are described briefly, with ...
In order to establish coal NOx preventive measures, discussions were given on formation of N2 in the fixed-bed pyrolysis of low rank coals and the mechanisms thereof. Chinese ZN coal and German RB coal were used for the discussions. Both coals do not produce N2 at 600{degree}C, and the main product is volatile nitrogen. Conversion into N2 does not depend on heating rates, but increases linearly with increasing temperature, and reaches 65% to 70% at 1200{degree}C. In contrast, char nitrogen decreases linearly with the temperature. More specifically, these phenomena suggest that the char nitrogen or its precursor is the major supply source of N2. When mineral substances are removed by using hydrochloric acid, their catalytic action is lost, and conversion into N2 decreases remarkably. Iron existing in ion-exchanged condition in low-rank coal is reduced and finely diffused into metallic iron particles. The particles react with heterocyclic ...
Burner for feeding a solid and a liquid or gaseous fuel to a kiln comprises a central supply pipe for liquid or gas surrounded concentrically by a first pipe providing an annular passage through which primary air is supplied. Concentrically surrounding that pipe is a second pipe providing an annular channel for supply of solid fuel in carrier air stream. The outlet end of the first concentric pipe is closed by a plate fixed mounted at the pipe end and providing multiple nozzles having their axes parallel to the burner axis. The surface of the plate facing the burning zone provides a divergence opening for the central pipe while the inner surface is formed with helical teeth. These are engaged by complementary teeth mounted on the end of the central pipe which is rotatable and biased by springs so that the teeth are in engagement. Rotation of the pipe causes relative axial motion of the teeth to create tangential slots for admission of primary air into the central pipe. The second ...
A calculation model was developed for the analysis of thermal and hydraulic processes in the PGV-1000 horizontal steam generator. The model makes it possible to examine the hydraulics of the primary medium, i.e., the distribution of flow velocities and mass flows in the exchanger tube system and hydraulic losses of the primary medium in the steam generator during its flow between the two connecting sites to the main circulation pipeline, spatial distribution of heat fluxes between the primary and secondary sides of the steam generator and the total transmitted thermal power, pressure on the secondary side of the generator, natural circulation of the working medium on the secondary side, and the mean circulation number, spatial distribution of the volume fraction of the steam component in the intertubular space, effect of the perforated sheet on the thermo-hydraulic processes in the steam generator, redistribution of the steam component in the ...
One of the important aspects in an absorption system is the effectiveness in which the gas and liquid phases come into contact with each other. An effective absorption process will provide sufficient contacting area for the gas and liquid phases to interact upon. With this in mind, work was conducted to evaluate carbon dioxide (CO{sub 2}) absorption into aqueous solutions of monoethanolamine (MEA) using two different types of contacting devices: gas absorption membrane (GAM) modules and traditional packed columns. The performance of these two absorption devices was compared to one another using the overall mass transfer coefficient (K{sub G}a{sub v}) as a basis. The GAM module contained microporous polypropylene hollow fibre membranes and the packed absorption column contained Sulzer DX structured packing. The results indicate that GAM modules tend to have ...
This paper shows that a well designed transport system has an embedded exchange value by serving as a market for potential exchange between consumers. Under suitable conditions, one can improve the welfare of consumers in the system simply by allowing some exchange of goods between consumers during transportation without incurring additional transportation costs. We propose an explicit valuation formula to measure this exchange value for a given compatible transport system. This value is always nonnegative and bounded from above. Criteria based on transport structures, preferences and prices are provided to determine the existence of a positive exchange value. Finally, we study a new optimal transport problem with an objective taking into account of both transportation cost and exchange value.
This document reports the results of testing of spent ion exchange media pretreatment technologies. Emphasis of the testing activities has been on screening pretreatment technologies, such as drying and emulsification, which are compatible with vitrification, cementation, and incineration. Ion exchange media tested for cementation and incineration pretreatment technologies were typical organic ion exchange resins and inorganic zeolites. The ion exchange medium tested for vitrification pretreatment technologies was inorganic zeolite. The results of testing activities are discussed in detail in this report.
We present evidence for the creation of an exchange spring in an antiferromagnet due to exchange coupling to a ferromagnet. X-ray magnetic linear dichroism spectroscopy on single crystal Co/NiO(001) shows that a partial domain wall is wound up at the surface of the antiferromagnet when the adjacent ferromagnet is rotated by a magnetic field. We determine the interface exchange stiffness and the antiferromagnetic domain wall energy from the field dependence of the direction of the antiferromagnetic axis, the antiferromagnetic pendant to a ferromagnetic hysteresis loop. The existence of a planar antiferromagnetic domain wall, proven by our measurement, is a key assumption of most exchange bias models.
Ketamine-anesthetized Sprague-Dawley rats were exposed in H orientation to far-field 9.3-GHz continuous-wave (CW) and pulsed (2 microseconds 500 pps) radiofrequency radiation (RFR) at average power densities of 30 and 60 mW/sq. cm (whole-body average specific absorption rates of 9.3 and 18.6 W/kg, respectively). Irradiation was conducted to cyclicly increase colonic temperature from 38.5 to 39.5 C. Colonic, tympanic, and subcutaneous temperatures, ECG, blood pressure, and respiratory rate were continuously recorded during experimentation. At both power densities, the subcutaneous and tympanic temperature increases significantly exceeded the colonic temperature increase. At both exposure levels, heart rate increased significantly during irradiation and returned to baseline when exposure was discontinued. Blood pressure and respiratory rate did not significantly change during irradiation. There were no significant differences between the effects of CW and pulsed RFR ...
The MTX experiment was proposed in 1986 to apply high frequency microwaves generated by a free-electron laser (FEL) to electron cyclotron resonance heating (ECRH) in a high field, high density tokamak. As the absorption of microwaves at the electron cyclotron resonance requires high frequencies, the opportunity of applying a free-electron laser has appeal as the device is not limited to frequencies in the microwave or long millimeter wavelength regions, in contrast to many other sources. In addition, the FEL is inherently a high power source of microwaves, which would permit single units of 10 MW or more, optimum for reactors. Finally, it was recognized early in the study of the application of the FEL based on the induction linear accelerator, that the nonlinear effects associated with the intense pulses of microwaves naturally generated would offer several unique opportunities to apply ECRH to current drive, MHD control, and other plasma ...
Ketamine-anesthetized Sprague-Dawley rats were exposed to far-field 700-MHz continuous-wave radiofrequency radiation (RFR) in both E and H orientations. Irradiation was conducted at whole-body average specific absorption rates (SARs) of 9.2 and 13.0 W/kg (E and H, respectively) that resulted in approximately equivalent colonic specific heating rates (SHRs). Exposures were performed to repeatedly increase colonic temperature by 1 deg C (38.5 to 39.5 deg C). Tympanic, tail, left and right subcutaneous (toward and away from RFR source), and colonic temperatures, arterial blood pressure, and respiratory rate were continuously recorded. In spite of equivalent colonic SHRs and the reduced E-orientation average SAR, the right subcutaneous, tympanic, and tail SARs, SHRs and absolute temperature increases were significantly greater in E than in H orientation. The cooling rate at all monitoring sites was also significantly greater in E than in H ...
The absorption of carbonyl sulfide in aqueous methyldiethanolamine (MDEA) was studied over a range of temperatures and MDEA concentrations. MDEA is commonly used for selective absorption of hydrogen sulfide in the presence of carbon dioxide. However, sulfur in the form of COS may also be present and it is necessary that estimates of absorption rates of this compound be made. The objective of this study is to determine the physiochemical properties needed to predict COS absorption rates in aqueous MDEA. Free gas solubility and the diffusivity of COS in MDEA solutions were measured over the temperature range 15 to 40{sup 0}C for MDEA concentrations up to 30 weight per cent using the nitrous oxide analogy method. Solubilities were measured volumetrically in an equilibrium cell and diffusivities were measured using a laminar liquid jet absorber. The kinetics of the reaction between COS and MDEA were studied ...
... turbine blade heat-transfer and study the heat-transfer augmentation in idealized geometry and its ... responsible for heat transfer augmentation. ...
The presented paper describes the formulation of the fractional mass balances which are used to calculate the concentration and size distribution of char in the balance cells of a circulating fluidized bed boiler. In case of using the shrinking core model additionally the distribution of conversion of the char particles is calculated. Basically two reaction models (a shrinking particle and a shrinking core model) are available to describe the combustion process. The model considers all essential physico/chemical phenomena (primary fragmentation, attrition, mass transfer to gas phase) which have to be taken into account for the description of the combustion process. The model is part of an overall simulation program for circulating fluidized bed boilers. This engineering simulator has been developed to return the main performance parameters of such systems like temperature along the furnace height, size distribution of balanced solid components, heat flows at the ...
Power source requirements for the military were presented to provide guidelines for research and development planning. Power sources that contain a high amount of energy and are small, light and durable are a common request from military users. Safety, reliability and low temperature performance are also important factors in the selection of power sources, as are cost and energy efficiency. Issues concerning advanced batteries were reviewed with reference to high energy density cathode materials. Various thermoelectric and renewable energy materials were discussed, with reference to recovery and conversion of waste heat. It was suggested that photovoltaic devices could help revolutionize military logistics by modifying energy re-supply requirements. Solid Oxide Fuel Cells (SOFC) were considered in relation to the high price of the ceramic materials required for operation. It was noted that the development of SOFC anodes capable of generating hydrogen from liquid ...
This handbook provides the necessary tools for the engineer to design forced-cooled HPOF pipe-type cable systems. It represents the final objective of a major project which included an extensive research program at the Waltz Mill Forced-Cooling Test Facility. The formulas and procedures presented in this handbook are consistent with the results of this program as well as other full-scale and model investigations. Introductory material, including historical information, general design concepts and basic heat transfer and fluid dynamics theory is given for those who are unfamiliar with the fundamental principles of forced-cooling. The nucleus of the handbook consists of equations and calculating procedures for determining forced-cooled parameters and thermal/hydraulic performance levels. Both simple and sophisticated procedures have been provided, with the more complex procedures treating such areas as the thermal interaction between cable pipes as well as the ...
One of the five projects selected for funding within the Clean Coal Technology Program is a project proposed by the Pennsylvania Electric Company (Penelec) of Johnstown, Pennsylvania. Penelec proposes to enter into a cooperative agreement with DOE to design, construct and operate a 600 ton-per-day, 66-megawatt (MWe), coal-fueled, externally-fired combined cycle (EFCC) electric power generation facility. The EFCC is an emerging technology with promise for operating highefficiency combined gas- and steam-turbine cycles on coal. The central feature of EFCC is its coupling of the gas turbine to an external, atmospheric-pressure, coal combustor via a hightemperature ceramic heatexchanger (CerHx{reg_sign}) developed by Hague International. The EFCC technology is attractive because, unlike competing combined cycles such as Integrated Gasification (IGCC) and Pressurized Fluidized Bed Combustion (PFBC), it eliminates the need for a costly gas cleanup ...
A number of binary geothermal cycles utilizing mixed hydrocarbon working fluids were analyzed with the overall objective of finding a working fluid which can produce low-cost electrical energy using a moderately low temperature geothermal resource. Both boiling and supercritical shell-and-tube cycles were considered. The performance of a dual-boiling isobutane cycle supplied by a 280/sup 0/F hydrothermal resource (corresponding to the 5MW pilot plant at the Raft River site in Idaho) was selected as a reference. To investigate the effect of resource temperature on the choice of working fluid, several analyses were conducted for a 360/sup 0/F hydrothermal resource, which is representative of the Heber resource in California. The hydrocarbon working fluids analyzed included methane, ethane, propane, isobutane, isopentane, hexane, heptane, and mixtures of those pure hydrocarbons. For comparison, two fluorocarbon refrigerants were also analyzed. Preliminary estimates of relative ...
The radionuclide characteristics of light-water-reactor (LWR) spent fuel play key roles in the design and licensing activities for radioactive waste transportation systems, interim storage facilities, and the final repository site. Several areas of analysis require detailed information concerning the time-dependent behavior of radioactive nuclides including (1) neutron/gamma-ray sources for shielding studies, (2) fissile/absorber concentrations for criticality safety determinations, (3) residual decay heat predictions for thermal considerations, and (4) curie and/or radiological toxicity levels for materials assumed to be released into the ground/environment after long periods of time. The crucial nature of the radionuclide predictions over both short and long periods of time has resulted in an increased emphasis on thorough validation for radionuclide generation/depletion codes. Current radionuclide generation/depletion codes have the capability to follow the ...
A method is reported which permits selective suppression of absorption of radioactive strontium from ingested food material, permitting the calcium to be available to the body. Studies were carried...Full Text Available
A retrospective study of the relationship of season to the absorption of radiolead in laboratory rats was performed using data representing 305 animals from 36 experiments over 6 calendar years. Male...Full Text Available
BackgroundSeveral aromatic amines (AA) could cause bladder cancer and are an occupational hygiene problem in the workplace. However, little is known about the percutaneous absorption...Full Text Available
A liquid column was used for the experiments reported in Part 1. However, it only gives the observation of the effect of fast reaction because the liquid flow was controlled to uniform laminar flow and the contact is limited to short time of around 10 ms. In practical absorbing operation, turbulence is involved in liquid flow, and the residence time for contact is long. Hence, the absorption of trace iodine in the purified air has been experimented by using a constant interface area type stirred absorption tank. Prior to the experiment, the characteristics of the absorption tank was investigated by conducting pure carbon dioxide absorption test with purified water. It gave the conclusion that the tank was sufficiently usable for fundamental researches. In short contact time absorption, the iodine dissolved and absorbed in liquid phase is affected by reaction of hypoiodous acid and ...
To investigate the fate of intrinsic factor and cobalamin during cobalamin absorption, we incubated enterocytes isolated from guinea pig ileum for periods of up to 30 min with 57Co-labeled...Full Text Available
1. Rates and rate coefficients of glucose utilization and replacement in post-absorptive rats, either conscious or under halothane anaesthesia, were determined in a thermoneutral environment by using...Full Text Available
Concentration of an amine solution for removal of hydrogen sulfides and carbon dioxide from natural gas, is tested by carbon dioxide absorption measurement in an apparatus allowing complete reaction to give reliable results.
In this note it is suggested that binuclear platinum(II) complexes with a solely inorganic bridging pyrophosphito ligand also possess many of the complementary advantages of inorganic and organic dyes. They are evaluated for their potential use as a luminescent solar concentrator material. The disadvantages include: the high cost of platinum; the absorption spectra in solution shows a weaker absorption at 452 nm which may cause reabsorption of emitted light; the positions of the absorption and emission maxima are not at the optimal wavelengths for absorption of sunlight and emission to a solar cell. In spite of these drawbacks the author believes the platinum complexes merit consideration for fabrication of solar concentrator devices.
This is a preliminary study on the sound absorption properties of two tropical hardwoods, Light Red Meranti and Ramin, and their wood-polymer composites. Sound absorption is measured using a standing wave apparatus. The samples are of one thickness (7 mm) and cut longitudinally. Wood-polymer composites are made by impregnating the samples with methyl methacrylate which is polymerized in situ through #gamma#-irradiation. Both woods and their composites are better sound absorbers at higher sound frequencies. With partial impregnation, the absorption coefficients are improved upon particularly in the region between 1-3 kHz. (author).
... significant change of spontaneous radiation intensity. It is very sensitive technique allowing the observation of small changes of light absorption. ...
We theoretically investigate the features of two-photon absorption in a coherently driven four-level atomic system with closed-loop configuration. It is found that two-photon absorption can be completely suppressed just by properly adjusting the relative phase of four coherent low-intensity driving fields and the atomic system becomes transparent against two-photon absorption. From a physical point of view, we explicitly explain these results in terms of quantum interference induced by two different two-photon excitation channels.
Rats and guinea pigs were fed "2"3"8Pu either biologically incorporated into alfalfa (by growth of the plant on soil containing Pu) or added as a solution to alfalfa, or were gavaged with a Pu solution. Depending upon the plant material fed, there appeared to be a twofold increase in "2"3"8Pu-gut absorption by the rat and a two- to fourfold increase in the guinea pig as compared with absorption from the Pu solution. The data, though limited and variable, suggest that Pu bound to plant tissue may have higher gut absorptivity than inorganic Pu in both herbivorous and nonherbivorous rodents.
... energy absorption characteristics of composite sandwich panels, thermoplastic energy-absorbing subfloor structures, and shoulder belt pre- tensioners. ...
Spectral absorption properties of total suspended matter (TSM) and colored dissolved organic matter (CDOM) are important for the use of the bio-optical model to estimate water quality parameters. This study aims to investigate the variation in the absorption coefficients of TSM and CDOM of inland waters. A total of 92 water samples were collected from Shitoukoumen Reservoir and Songhua Lake in Northeast China, analyzed for TSM and Chl-a, and measured for the absorption coefficient of TSM, CDOM and total pigments using a laboratory spectrophotometer. The absorption coefficient of TSM has been decomposed for phytoplankton and inorganic sediments. The results show that for Shitoukoumen Reservoir, CDOM has strong absorptions with shallow absorption slopes (i.e., the coefficient S in a(?)=a(?0)exp[-S(?- ?0)]) and large absorption at 355 nm; and ...
In studying the absorption of carbon dioxide by absorbents impregnated with alkanol amines, researchers used a laboratory-scale packed column to determine the overall gas-phase mass-transfer coefficients and enhancement factors. A model derived for the mechanism of the chemical reaction taking place in the interfacial layer accounts for the effect of the reaction upon the absorption rate better than other models.
The application of differential optical absorption (DOA) techniques for the in-situ determination of the chemical composition of coal gasification process streams is investigated. Absorption spectra of relevant molecular species and the temperature and pressure effects on DOA-determined spectral characteristics of these species will be determined and cataloged. A system will be configured, assembled, and tested.
An equation is described to estimate the value of the liquid-phase mass-transfer coefficient of aqueous solutions of surfactants from its value for pure water. The form of the equation is obtained from Levich's theory, and it is adjusted to experiments of absorption of CO/sub 2/ in aqueous solutions of five pure surfactants. The reduction of the absorption rate is correlated with the interfacial pressure of the solution.
The absolute absorption of ozone in the midinfrared has been measured relative to 253.7-nm ultraviolet absorption to an accuracy of 1% using a Bruker Fourier transform spectrometer. These new results agree with previous measurements by diode laser measurements after the latter are corrected for more recent infrared calculations and ultraviolet cross sections. They also agree with a determination based on refractive index measurements in the infrared. 16 refs., 4 figs., 3 tabs.
The report gives results of a pilot-plant study of the ammonia absorption/ammonium bisulfate regeneration process for removing SO2 from the stack gas of coal-fired power plants. Data were developed on the effects of such operating variable in the absorption of SO2 by ammoniacal l...
The synthetic process of polyethylene cation exchange capillary via radiation grafting polystyrene by simultaneous irradiation with "6"0Co #gamma#-ray source and sulfonation with concentrated H_2SO_4 was studied. The effects of dose, dose rate, monomer concentration, solvents, temperature and crosslinking agents on the graft copolymerization of styrene with polyethylene capillary were illustrated. The relationship between the radiation grafting conditions and the properties of ion-exchange capillary were examined. A polyethylene cation exchange capillary with I.D. 0.8 mm, length 20 m, exchange capacity 0.7 Meq/g 60% capacity in 10 s (flow rate 20 ml/min) was prepared. No significant loss of copacity was found from this ion-exchange capillary after 200 adsorption/regeneration cycles.
In this work, a comprehensive model has been developed for the absorption of carbon dioxide into promoted hot potassium carbonate solution. The model, which is based on penetration theory, incorporates an extensive set of important reactions and takes into account the coupling between mass transfer and chemical kinetics. The penetration theory provides an appropriate absorption rate and enhancement factor for the chemical absorption. Operating data for carbon dioxide absorption into DEA-hot potassium carbonate solution has been compared with model predictions. The impact of parameters such inlet temperature of lean solution, promoter concentration, liquid split fraction, hot feed location and type of promoter on the performance of a split-flow absorber have been examined. The use of other promoters is an efficient way to enhance the carbon dioxide absorption, which has been ...
Gastrointestinal patches represent a novel multiparticulate drug delivery system able to increase the intestinal absorption of drugs with poor bioavailability. The number of patches to administer is a critical issue since it is related to the surface and drug concentration at the absorption site. The objective of this article is to evaluate the effect of the number of administered patches on the final absorption of leuprolide, a peptide chosen as model drug, assuming complete adhesion of all the devices to the intestinal membrane. The same dose of leuprolide was encapsulated into 2, 4 and 6 patches; the resulting intestinal absorption profiles were measured with the Ussing chamber ex vivo experimental setup and compared between them. The results showed that varying the number of patches, t...
Measurements of local mass fluxes of liquid, local number fluxes of the drop and local drop size distributions at various locations in the test column were made for wide ranges of liquid flow rates and gas flow rates. An empirical correlation for the volume mean diameter of the drop at the nozzle exit was proposed. Measurements of the rates of absorption of carbon dioxide from carbon dioxide-air mixtures with water sprays (physical absorption) and aqueous sodium hydroxide sprays (chemical absorption) were made for wide range so fluid flow rates, feed gas concentrations, and initial alkali concentrations. The observed dimensionless rates of absorption were compared with the theoretical values by assuming penetration model with second-order irreversible reaction. 11 refs., 7 figs.
For terrestrial animals and plants, a fundamental cost of living is water vapor lost to the atmosphere during exchange of metabolic gases. Here, by bringing together previously developed models for...Full Text Available
Cytosol proteins prepared from castor bean endosperm (4-day-old) seedlings stimulate the exchange of [3H]phosphatidylethanolamine between liposomes and mitochondria. The acceleration of the...Full Text Available
Plasma exchange (PE) is currently being used to treat a variety of disorders involving immune complexes, such as polyarteritis nodosa. This procedure removes endogenous toxic components that accumulate...Full Text Available
Background:The cardiac sodium–calcium exchanger (NCX1) is a key sarcolemmal protein for the maintenance of calcium homeostasis in the heart. Since heart failure...Full Text Available
The continued evolution of bacterial pathogens has major implications for both human and animal disease, but the exchange of genetic material between host-restricted pathogens is rarely considered....Full Text Available
We analyse the relation between the exchange algebra and the separation of the chiralities in classical Toda field theory. We show that there exists a conformally covariant Bloch wave basis such that the two chiralities commute. In terms of this basis we then reconstruct the periodic and local solution of Toda field theory. (orig.).
Severance of the ureter beyond the renal papilla causes a fall in urinary osmolality, which suggests that exchange of water or solute between urine and renal parenchyma normally occurs in the intact...Full Text Available
The effects of Escherichia coli endotoxin on lung mechanics, hemodynamics, gas exchange, and lung fluid and solute exchange were studied in 12 chronically instrumented unanesthetized sheep. A possible...Full Text Available
An anion-exchange column technique for extraction of antibiotics from serum proteins has been developed for use in the assay of cephapirin, cefotaxime, and cefoxitin by high-pressure liquid chromatography....Full Text Available
Separation of lithium isotopes was investigated by chemical ion exchange with a hydrous manganese(IV) oxide ion exchanger using an elution chromatography. The capacity of manganese(IV) oxide ion exchanger was 0.5 meq/g. The heavier lithium isotope was enriched in the solution phase, while the lighter isotope was enriched in the ion exchanger phase. The separation factor was determined according to the method of Glueckauf from the elution curve and isotopic assays. The separation factor of {sup 6}Li{sup +} -{sup 7}Li{sup +} isotope pair fractionation was 1.018.
The possibility of switching the heat transfer consists of varying heat transfer surfaces and making the heat transfer temporarily more intensive. Heat tubes prove to be particularly suitable, which must be exposed to a heat carrier fluid or removed from its effect for switching the heat transfer. This report gives a survey of the possibilities of switching heat flows and for making the heat transfer more intensive. Further, the report contains a survey of patents limited to heat transfer in the fields of cooling internal combustion engines and exhaust systems. (orig.) With 17 figs., 183 refs.
Using the PMR method the interaction of zirconium and hafnium tetrachlorides with tri.tet.butylphenyl ester of 1,2- naphthoquinonediazide (2)-5-sulfonic acid is studied. The formation of MCl/sub 4/xNQD complexes is established, the equilibrium constants and thermodynamic parameters of complexing reaction are determined. The presence of rapid ligand exchange, proceeding according to associative mechanism, is detected. The rate constants and activation energies of the exchange reaction are calculated.
Using the PMR method the interaction of zirconium and hafnium tetrachlorides with tri.tet.butylphenyl ester of 1,2- naphthoquinonediazide (2)-5-sulfonic acid is studied. The formation of MCl_4xNQD complexes is established, the equilibrium constants and thermodynamic parameters of complexing reaction are determined. The presence of rapid ligand exchange, proceeding according to associative mechanism, is detected. The rate constants and activation energies of the exchange reaction are calculated.
Classical molecular dynamics simulations are carried out to investigate the salvation shell exchange kinetics of potassium ion in bulk water, chloroform, and carbon tetrachloride. The reactive flux method is used to compute the dissociation rates. The influence of the solvent on the reaction rates and kinetic properties of this exchange process will be discussed. Comparison will be also be made to the prediction of the Grote-Hynes theory.
This paper illustrates how the techniques developed by the authors for capital cost targeting of mass exchange networks can be applied to determination of capital investment targets for reduction in effluent for existing systems involving mass exchange. The results is an impact diagram which shows the relationship between effluent reduction and capital investment, indicating a region of limiting return on investment as well as the maximum possible reduction in effluent. (au)
Full text of publication follows: Understanding the dynamic irradiation effects on silica glasses is important for developing the diagnostic systems used in fusion and fission environments. While fundamental defects having an un-pared electron such as the E' center have been extensively studied, the neutral oxygen deficiency defects have been insufficiently clarified for lack of the detection methods. The ion induced luminescence is one of the probes that can be used to detect non-paramagnetic defects, and to observe creation and annihilation behavior dynamically. In the present study, we examined the characteristics of the ion induced luminescence such as energy, fluence flux and temperature dependence of the luminescence efficiency to analyze damage process quantitatively. Samples of SiO2 glasses were commercially available fused and synthesized silica glasses, produced by Toshiba Ceramics, Co. Ltd.. A thin films of SiO2 deposited on a Si wafer was used to determine the luminescence ...
During earlier work rapid and highly sensitive Jet-REMPI (resonance-enhanced multiphoton ionization) mass spectrometry was applied for monitoring the effluent from thermal treatment of a filter dust during a de novo test under laboratory conditions. The sample, from ESP-Field 2 of an iron ore sintering plant, was already loaded with dioxins ({sigma}PCDD/F = 132 ng/g), their precursors (PCBz, PCPh) and other products of incomplete combustion. Heating filter dust in a temperature window 200-350 C under a flow of air results in further formation of these pollutants. As described elsewhere, on-line detection was mostly carried out using a non-selective ionization mode, to measure a wide range of compounds simultaneously. The changes of output suggest that the reaction products increase in chlorination level with time. Another explanation is that higherchlorinated compounds appear later as a consequence of lower volatility and stronger adsorption. However, due to mass ...
With an objective to know coal condensation structure which has influence on coal conversion reaction, an attempt was made on quantitative evaluation of hydrogen bonding in coal. Using as test samples the VDC made from Taiheiyo coal swollen by tetralin and vacuum-dried, and its pyrolyzed char, DSC measurement and Fourier transform infrared spectroscopy (FT) were performed. An FT spectrum comparison revealed that the VDC swollen at 220{degree}C has the hydrogen bonding relaxed partly from the original coal. However, since the change is in a huge coal molecular structure restraining space, it has stopped at relaxation of the bonding energy without causing separation as far as free radicals. On the other hand, the DSC curve shows that the VDC has slower endothermic velocity than the original coal. In other words, the difference in heatabsorption amounts in both materials is equivalent to the difference of enthalpy ({Delta} H) of both materials, ...
Norway is privileged with extensive resources of natural gas, oil and hydropower. Location of gas fired combined cycle (CC) power plants in Norway offers advantages due to the availability of natural gas from the Norwegian continental shelf and fairly low ambient temperatures, giving high fuel-to-electricity conversion efficiency. The continental shelf provides large storage capacity for CO{sub 2} in deep saline aquifers and in drained gas fields. In this paper the results of extensive work on CO{sub 2} capture carried out during the last years by Statoil in co-operation with several engineering contractors, are presented. The goal has been to develop a commercially viable concept for a combined cycle power plant including CO{sub 2} capture and sequestration. The main concept is based on CO{sub 2} capture from exhaust gas from a combined cycle power plant, using absorption by amine (MEA) solutions. The CO{sub 2} is compressed, transported by pipeline and stored in ...
The absorption of solar heat and the attendant thermal and mechanical loadings on the tubes of cavity receivers depend predominantly on the flux distribution of the incident solar radiation. For an axially symmetric cavity receiver with a parabolic dish collector, it is simple to determine the insolation pattern on the receiver internal surfaces if the system is ideal. In such a system the surface of the dish is perfectly parabolic (no contour flaws are present), and the sun's central ray impinges on the dish surface parallel to the focal axis (no sun tracking flaws are present). These two conditions cannot be achieved in practice, and therefore the feasible parabolic dish system is referred to as a real system although, in actual fact, it is only an approximation to any actual system. The purpose of this paper is to devise calculation principles which permit analysis of a receiver designed for ideal conditions to verify its structural ...
The rate coefficient for the title reaction has been determined using mixtures of nitric acid (HNO{sub 3}), carbon monoxide (CO), and argon in incident shock wave experiments. Upon shock heating, the nitric acid rapidly decomposes into OH and NO{sub 2}. The OH subsequently reacts predominantly via the title reaction. Quantitative OH time histories were obtained by continuous-wave (cw) narrow-linewidth UV laser absorption of the R{sub 1}(5) line of the A{sup 2}{Sigma}{sup +} {l_arrow} X{sup 2}{Pi}{sub i} (0,0) transition at 32,606.56 cm{sup {minus}1} (vacuum). In some experiments, helium was added to the reactant mixture to examine CO vibrational excitation effects on the rate coefficient determination. It was found that the rate of excited CO (v = 1) with OH is less than the rate of ground-state CO (v = 0) with OH, which is in agreement with previous state-dependent work. The experiments were conducted over the temperature range 1,090--2,370 K ...
A simple method is presented for the separation of lead-203 from copper-backed thallium cyclotron targets. The procedure involves cation-exchange chromatography in hydrochloric acid and hydrochloric acid-acetone mixtures. Further purification involves anion-exchange chromatography in nitric acid-hydrobromic acid mixtures. A cation-exchange column containing 3.0 g of resin can handle as much as 15 g of thallium and 160 mg of copper. An anion-exchange column containing 3.0 g of resin can separate lead from up to 200 mg of thallium and 10 mg of copper. Separations are extremely sharp and less than 0.1 ..mu..g of thallium and less than 0.1 ..mu..g of copper remain in the lead-203 fraction.
A simple method is presented for the separation of lead-203 from copper-backed thallium cyclotron targets. The procedure involves cation-exchange chromatography in hydrochloric acid and hydrochloric acid-acetone mixtures. Further purification involves anion-exchange chromatography in nitric acid-hydrobromic acid mixtures. A cation-exchange column containing 3.0 g of resin can handle as much as 15 g of thallium and 160 mg of copper. An anion-exchange column containing 3.0 g of resin can separate lead from up to 200 mg of thallium and 10 mg of copper. Separations are extremely sharp and less than 0.1 #mu#g of thallium and less than 0.1 #mu#g of copper remain in the lead-203 fraction. (author).
In this study, the use of the weakly basic anion exchange resins of phenol-formaldehyde (Amberlyst A 23), polyacrylate (Amberlite IRA 67) and polystyrene (Lewatit MonoPlus MP 62) matrices for removal of the reactive dye Remazol Black B (RBB) from aqueous solution and wastewater were investigated. RBB sorption on the anion exchangers was a time dependent process. Color reduction percentiles of 75.2, 33.9 and 25.1% in wastewater treatment were found after 216 h of phase contact time with Lewatit MonoPlus MP 62, Amberlyst A 23 and Amberlite IRA 67, respectively. Inorganic salts and anionic surfactant action influenced RBB uptake by the anion exchangers. The amounts of dye retained by the anion exchangers increased with a rise in temperature. The maximum sorption capacities calculated from the...
This paper employs a new approach in order to investigate the underlying relationship between stock markets and exchange rates. Current approaches suggest that the relative equity market performance of two countries is linked to their exchange rate. In contrast, this study proposes an alternative approach where one global variable - global equity market returns - is believed to have an effect on exchange rates, with the relative interest rate level of a currency determining the sign of the relationship. Our empirical findings suggest that exchange rates and global stock market returns are strongly linked. The value of currencies with higher interest rates is positively related with global equity returns, whereas the value of currencies with lower interest rates is negatively related with g...
The performance of spherical Resorcinol-Formaldehyde ion-exchange resin for the removal of cesium from alkaline radioactive waste solutions has been investigated through computer modeling. Cesium adsorption isotherms were obtained by fitting experimental data using a thermodynamic framework. Results show that ion-exchange is an efficient method for cesium removal from highly alkaline radioactive waste solutions. On average, two 1300 liter columns operating in series are able to treat 690,000 liters of waste with an initial cesium concentration of 0.09 mM in 11 days achieving a decontamination factor of over 50,000. The study also tested the sensitivity of ion-exchange column performance to variations in flow rate, temperature and column dimensions. Modeling results can be used to optimize design of the ion exchange system.
The contribution of exchange processes (heavy stripping and substitution) into the amplitude of the 25-30 MeV #alpha#-particle elastic scattering by "1"2C and "4"0Ca nuclei is examined taking into account the distortion of plane waves of initial and finite particles. The eikonal approximation is used for accounting for distortions. The matrix elements of exchange processes are calculated. The results of calculations show that the Wronskian cutoff radii are close to those which have been obtained for calculation of exchange processes in the plane-wave approximation. The moduli of the values defining the contribution of exchange processes to the total S matrix are plotted. Also presented are Argand diagrams and angular distributions for both reactions. It has been established that the account for exchange processes improves the agreement of theoretical curves with the experiment in ...
A research was started aiming at evaluating the possible use of natural zeolites as exchange conditioners to improve and make durable the soil resilience against the adverse effects of the use of anomalous waters for irrigation purposes. This paper deals with a preliminary investigation on the comparative resilience of an Entisol with poor exchange properties and of a Neapolitan yellow tuff (NYT) sample against the adverse features of a dirty municipal sewage (DSW). Results showed that NYT treatment largely and significantly improved the poor soil exchange activity. In particular. NYT exchange sites selectively took up ammonium from DSW. As a consequence, ammonium was trapped, then protected against losses in the environment and, concurrently, exchangeable cations, such as K and Ca, were made free as plant nutrients. The results highlight the possible positive role of zeolitized ...
Theoretical and experimental results of investigating a cylindrical heat receiver with secondary reflectors are presented. One important element of solar thermal power plants (STPP) is the heat receiver. Several forms of heat receiver exist; the main form is the heat receiver of cavity form (including cylindrical, rectangular, and cubic heat receivers with a noncircular aperture). The linear dimension of such heat receivers is equal to, or larger than, the theoretical diameter of the concentrator focal spot.
Purpose : To obtain an emergency core cooling device in a FBR type reactor by utilizing heat pipes which are not actuated at usual operation condition but actuated reliably upon emergency. Constitution : A system for injecting heat medium into heat pipes is provided. By injecting the heat medium into the heat pipes upon emergency to actuate the heat pipes, the reactor core is cooled. During normal reactor operation, the inside of the heat pipes is evacuated from a vacuum pump and no heat medium is filled therein, whereby unnecessary heat loss during the normal operation can be prevented. (Ikeda, J.).
Nickel-based alloys are presently used as brazing filler metals for components which undergo mechanical stress in corrosive conditions, f. e. heatexchangers. When soldering chrome containing steel parts with nickel based brazing filler metals additionally containing boron and silicon a reaction of chrome and boron can occur. This evolution of chromium borides, depositing on grain boundaries, causes a lack of chrome in the steel part. A drop of the chrome content in the parts below 13 % leads to a loss of corrosion resistance. It is possible to change the microstructure of brazing joints by modification with chromium and molybdenum. Continuous brittle phases could be successfully avoided with this modification. Furthermore it could be shown that the choice of additives, the heating respectively cooling rate and the brazing temperature have important influence on the microstructure evolution and therefore on the mechanical ...
The most typical kinds of corrosion of brasses are selective corrosion (dezincification) and stress corrosion. Prevention against these kinds of corrosion lies in application of arsenic alloy addition and appropriate heat treatment removing internal stresses as well as in maintaining the arsenic and phosphorus contents on a proper level. The most typical corrosion of cupronickels is the local corrosion. Selective corrosion occurs less often and corrosion cracking caused by stress corrosion in sea water does not usually occur. Crevice corrosion is found especially in places of an heterogeneous oxidation of the surface under inorganic deposits or under bio-film. Common corrosive phenomena for brasses and cupronickels are the effects caused by sea water flow and most often the impingement attack. Alloy additions improve resistance to the action of intensive sea water flow but situation in this field requires further improvement, especially if the cheaper kinds of ...
This is the first text and reference book to be devoted completely to the very important and timely subject of heat transfer augmentation. This book is of equal appeal to both researchers and designers of heat transfer equipment.
Radioactive wastes are generally classified into 3 type depending on their physical property: liquid, solid and gaseous type. State-of -the art concerning liquid waste treatment has already been published; KAERI/TR-1315/99. Solid wastes classification package and treatment method will be studied to effectively manage them during the practical decommissioning work. All of the spent fuel produced during the operation of the TRIGA Mark-2 and 3 have been transported to the US last year, 1998, according to the spent fuel management strategy set-up by the US government for the non-proliferation of nuclear energy. Solid wastes are mainly all equipment existing inside of the reactors, activated concrete among the bio-shielded concrete, pipes, pimps, resin filter and it's housings, heat-exchangers, liquid waste storage tanks, to radioactive waste storage treatment facilities and so on. Solid wastes are generally low-level. They are classified according to the ...
Conventional eddy current bobbin probes are known to be ineffectual in detecting circumferential cracks in tubing. Multi-pancake and/or rotating pancake probes are required to detect circumferential cracks. It has recently been demonstrated in CANDU steam generator tubes, with deformation, ferromagnetic deposits, and copper deposits, that multi-channel probes with transmit-receive (T/R) coils are superior to those using surface impedance coils. Unlike rotating probes, the design of a new probe denoted as C3 permits fast, single-scan inspection of a full-length tube at inspection speeds comparable to conventional bobbin probes. Since 1992, the probe has been used routinely for steam generator in-service inspection at 4 CANDU plants. Defective tubes have been plugged and the units returned to service, and they continue to operate without leaks. This paper describes the basic features of T/R surface probes. Two-dimensional voltage diagrams showing computer-derived probe response to ...
Conventional eddy current bobbin probes are known to be ineffectual in detecting circumferential cracks in tubing. Multi-pancake and/or rotating pancake probes are required to detect circumferential cracks. It has recently been demonstrated in CANDU steam generator tubes, with deformation, ferromagnetic deposits, and copper deposits, that multi-channel probes with transmit-receive (T/R) coils are superior to those using surface impedance coils. Unlike rotating probes, the design of a new probe denoted as C3 permits fast, single-scan inspection of a full-length tube at inspection speeds comparable to conventional bobbin probes. Since 1992, the probe has been used routinely for steam generator in-service inspection at 4 CANDU plants. Defective tubes have been plugged and the units returned to service, and they continue to operate without leaks. This paper describes the basic features of T/R surface probes. Two-dimensional voltage diagrams showing computer-derived probe response to ...
In the last two decades, due to increased inspection demands, eddy current instrumentation has advanced from single-frequency, single-output instruments to multifrequency, computer-aided systems. This has significantly increased the scope of eddy current testing, but, unfortunately, it has also increased the cost and complexity of inspections. In addition, this approach has not always improved defect detectability or signal-to-noise. Most eddy current testing applications are still performed with impedance probes, which have well known limitations. However, recent research at AECL has led to improved eddy current inspections through the design and development of transmit-receive (T/R) probes. T/R eddy current probes, with laterally displaced transmit and receive coils, present a number of advantages over impedance probes. They have improved signal-to-noise ratio in the presence of variable lift-off compared to impedance probes. They have strong directional properties, permitting probe ...
The titanium stabilized austenitic steel similar to the type of 321 is sensitive to the stress corrosion crackingunder horizontal steam generator operating condition. SCC was observed under crevice corrosion parameters and has resulted in the transgranular or intergranular cracking at the both, components primary collectors and heatexchange tubes. The crevice environment is characterized by aggressive impurities and 'non aggressive' compounds. Sulfates and chlorides as aggressive species and silicates and alumino-silicates as 'non aggressive' species on the other hand are present in significant amount in the crevice environment under operating condition. Local water chemistry parameters were evaluated with MULTEQ Code. As input data the measured operational values of local and bulk environments have been used. The determined parameters were compared with the results of thread hole environment analyses and ...
Since the very high temperature reactor (VHTR) components such as hot gas ducts and intermediate heatexchanger (IHX) are operated during a design life of 30 to 60 years at 950 .deg. C and 3-8MPa in He impurities, their components are required to have good high temperature strength, creep-rupture strength, high temperature stability, and good corrosion resistance. Among them, creep properties are the most important, because the integrity of their components should be preserved during a design life of over 30 years at the maximum operating temperature up to 1000 .deg. C. So far, there are no materials approved by ASME III which is a nuclear code for temperatures reaching 1000 .deg. C, and until now, a material selection is still left as a key issue. Some leading candidate alloys can be selected from the high temperature materials approved by ASME VIII. Alloy 617 is considered as a prospective material for the IHX because it has an excellent ...
About ten years ago microbiologically influenced corrosion manifested on stainless steel pipes used with river water for cooling a chemical plant. The pipe material was similar to Type 316 L. After only six weeks of operation pinhole leaks occurred nearly simultaneously at several welded joints of the pipe. The material degradation was simulated in laboratory and field corrosion tests. Microbiologically influenced corrosion failures also appeared on the pipes of a tubular heatexchanger of duplex steel Type 31803 and on carbon and stainless steel pipes in industrial waste water purification plants after these plants had been modernized with a biological purification unit. The basics of microbiologically influenced corrosion phenomena and typical corrosion failures of pipes will be described. (orig.) [German] Vor etwa zehn Jahren sind in einer neu errichteten chemischen Produktionsanlage an einer mit Flusswasser beaufschlagten Kuehlwasserleitung ...
The isostructural #gamma#-#alpha# phase transition of Ce which occurs at 8 kbar has been studied by means of fully self-consistent (non-muffin-tin potential) linearized-augmented-plane-wave energy band calculations carried out for five different values of the lattice constant. In contradiction to the 4f electron promotional model of the transition, the results yield essentially one 4f electron to be occupied in each phase but with the 4f wave function somewhat less localized, and therefore more bandlike, in the ''collapsed'' #alpha# phase. A singly occupied 4f state is shown to be consistent with the available experimental data. These results strongly support the picture of a 4f localized bold-arrow-left-right itinerant transition at the #gamma#-#alpha# transition and conflict with the promotional model in which some fraction of 4f electrons are transferred to the sd conduction bands. The weaker bonding of the 4f electrons, compared to that of the 6s-5d valence electrons, accounts for ...
A series of first principles molecular dynamics and Monte Carlo simulations were carried out for liquid water to assess the validity and reproducibility of different sampling approaches. These simulations include Car-Parrinello molecular dynamics simulations using the program CPMD with different values of the fictitious electron mass in the microcanonical and canonical ensembles, Born-Oppenheimer molecular dynamics using the programs CPMD and CP2K in the microcanonical ensemble, and Metropolis Monte Carlo using CP2K in the canonical ensemble. With the exception of one simulation for 128 water molecules, all other simulations were carried out for systems consisting of 64 molecules. It is found that the structural and thermodynamic properties of these simulations are in excellent agreement with each other as long as adiabatic sampling is maintained in the Car-Parrinello molecular dynamics simulations either by choosing a sufficiently small fictitious mass in the microcanonical ensemble ...
CNG vehicles suffer from an uncontrolled temperature rise of the gas inside the tank during the filling process and heatexchange with the environment leads to variable filling levels. A partly filled tank reduces the range of CNG vehicles and works as a impediment to the spreading of environmentaly more friendly CNG vehicles. The increase of the pressure inside the tank combined with a prolongation of the filling time beyond three minutes can reduce the deficit of the filling process. For economic reasons the time required for refuelling should be as short as possible without the need to operate the filling station with a critical pressure. To meet this target the current technique requires further improvement. (orig.) [Deutsch] Die betriebliche Praxis bei Tankvorgaengen von Erdgasfahrzeugen zeigt, dass waehrend des Tankvorganges die Temperatur des getankten Erdgases im Fahrzeugtank ansteigt. Waehrend und nach Beendigung des Tankvorganges ...
The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heatexchangers by monitoring Nitrogen-16 (16N) and Oxygen-19 (19O) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of 19O and 16N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high ambient radiation level even though sensitivity is appreciably good. For detector position in RB in the accessible areas and out side the RE containment, the ...
At the Borssele Nuclear Power Station, which has been in operation since 1973, a comprehensive program of modifications, one of the most extensive of its kind worldwide, was conducted in 1997 within the framework of an integral safety evaluation carried out at ten-year intervals, especially in the nuclear section. The collective dose associated with this activity was greatly reduced by Alara measures, one of which was chemical decontamination of part of the emergency and residual heat removal systems. An average decontamination factor (DF) of 17 was achieved by using the Siemens Cord UV process. Two decontamination cycles were required. The decontamination program took three days to be completed. The planned collective dose was reduced from 1029 mSv (without decontamination) to 335 mSv (on the basis of a DF of 8). Based on the DF of 17 achieved, the planned dose was corrected downward to 270 mSv. The dose finally achieved was 118 mSv. A total of 13.7 kg of metal ...
Sorption studies of cesium, strontium, and cobalt (Cs, Sr, and Co) on bentonite under various experimental conditions, such as contact time, pH, sorbent and sorbate concentration, and temperature, have been performed. The sorption data for all these metals have been interpreted in terms of Freundlich, Langmuir, and Dubinin-Radushkevich equations. Thermodynamics parameters, such as heat of sorption {Delta}H{degrees}, free energy change {Delta}G{degrees}, and entropy change {Delta}S{degrees}, for the sorption of these metals on bentonite have been calculated. The value of {Delta}H{degrees} shows that the sorption of Cs was exothermic, while the sorption of Sr and Co on bentonite were endothermic in nature. The value of {Delta}G{degrees} for their sorption was negative, showing the spontaneity of the process. The maximum loading capacity of Cs, Sr, and Co were 75.5, 22, and 27.5 meq, respectively, for 100 g of bentonite. The mean free energy E of Cs, Sr, and Co ...
Coupled modeling of subsurface multiphase fluid and heat flow, solute transport and chemical reactions can be used for the assessment of acid mine drainage remediation, mineral deposition, waste disposal sites, hydrothermal convection, contaminant transport, and groundwater quality. Here they present a numerical simulation model, TOUGHREACT, which considers non-isothermal multi-component chemical transport in both liquid and gas phases. A wide range of subsurface thermo-physical-chemical processes is considered. The model can be applied to one-, two- or three-dimensional porous and fractured media with physical and chemical heterogeneity. The model can accommodate any number of chemical species present in liquid, gas and solid phases. A variety of equilibrium chemical reactions is considered, such as aqueous complexation, gas dissolution/exsolution, cation exchange, and surface complexation. Mineral dissolution/precipitation can proceed either ...
AREVA is the world leader in the design and construction of nuclear power plants, the manufacture of heavy components, and the supply of nuclear fuel and nuclear services such as maintenance and inspection. The Equipment Division provides the widest range of nuclear components and equipment, manufactured at its two facilities in Jeumont, northern France, and St. Marcel, in Burgundy. The St. Marcel plant, set on 35 ha (87.5 acres) near Chalon-sur-Saone, was established in 1973 in a region with a long history of specialized metalworking and mechanical activities to meet the demand for non-military nuclear requirements in France. The site offers two advantages: - excellent facilities for loading and transporting heavy components on the Saone river, - it's proximity to other group sites. Since its completion in 1975, the Chalon/St. Marcel facility has manufactured all the heavy components for French pressurized water reactors (PWRs) ranging from 900 MW to 1500 MW. It has also ...
The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heatexchangers by monitoring Nitrogen-16 ("1"6N) and Oxygen-19 ("1"90) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of "1"9O and "1"6N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high background even though sensitivity is appreciably good. For detector position out side the RB containment, the travel time for the feed water becomes ...