A water calorimeter for high energy x-rays and electrons
The current primary standards at NPL for the measurement of absorbed dose to water in high energy photon and electron beams are graphite calorimeters. However, the quantity of interest in radiation dosimetry is absorbed dose to water. Therefore, a new absorbed dose to water standard based on water calorimetry has been developed for use in high energy photon and electron beams. The calorimeter operates at 4 deg C, with temperature control being provided by liquid cooling. The sealed glass inner vessel of the calorimeter was designed to minimise the effect of non-water materials on the measurement of absorbed dose. The temperature sensing thermistor probes were designed and constructed so that glass is the only material in contact with high purity water inside the vessel. Initial ...
2000-01-01
Determination of absorbed dose in a patient irradiated by beams of x or gamma rays in radiotherapy procedures
1976-01-01
International Nuclear Information System (INIS)
International standards and guidelines for calibrating high-dose dosimetry systems to be used in industrial radiation processing recommend that dose-rate effects on dosimeters be evaluated under conditions of use. This is important when the irradiation relies on high-current electron accelerators, which usually provide very high dose-rates. However, most dosimeter calibration facilities use low-intensity gamma radiation or low-current electron accelerators, which deliver comparatively low dose-rates. Because of issues of thermal conductivity and response, portable calorimeters cannot be practically used with high-current accelerators, where product conveyor speeds under an electron beam can exceed several meters per second and the calorimeter is not suitable for use with product handling systems. As an alternative, Monte Carlo calculations can give theoretical estimates of the ...
2007-08-01
Energy Technology Data Exchange (ETDEWEB)
A thermoluminescence (TL) sheet and its spatial readout system for in vivo measurement of spatial dose distribution around sources has been newly developed for intracavitary high dose-rate radiation therapy. The TL sheet (40 cm x 50 cm x 200 {mu}m), which is composed of teflon mixed with BaSO{sub 4} (Eu doped) powder, has a linear response with a very wide dynamic range from at least 0.002 cGy to 5000 cGy for {sup 60}Co sources. Phantom test of the TL sheet readout system demonstrated that absorbed dose with TL sheet and that with ionization chamber as standard dosimeter agreed well. For clinical application, TL sheet was attached on an applicator of intracavitary radiation therapy for rectal cancer. After irradiation with high dose-rate {sup 60}Co sources, the in vivo dose distribution on the surface of the rectum was determined. The TL ...
1991-06-01
Absorbed dose and dose reduction in mammography
International Nuclear Information System (INIS)
First, absorbed dose at entrance surface was measured in routine mammography. Secondly, a possibility of dose reduction after introduction of Fuji computed radiography (FCR) system was examined. In a total of 350 mammographic studies including craniocaudal and medilateral projections, average thickness of compressed breast was less than 4 cm and most frequently recorded absorbed dose was 0.2-0.3 cGy (200-300 mrad). Minimum dose to obtain clinically acceptable mammograms in FCR system was estimated by comparing image quality of routine versus reduced dose studies. It was concluded that absorbed dose could be reduced to 1/4 of routine dose without creating significant drawback in diagnosis. (author).
1986-01-01
Discrepancies in molar extinction coefficients of Fe"3"+ in Fricke dosimetry
International Nuclear Information System (INIS)
Values of the chemical yield, G, and of the molar extinction coefficient, epsilon, for Fricke dosimetry, have been recommended by ICRU. For epsilon, the value in ICRU Reports 17 and 21, 2205 1.mol"-"1.cm"-"1, based on an analysis of 83 reported values. It was suggested that, where neither a careful wavelength calibration nor absorbance linearity checks had been performed, a standard error of 1.5% should be assumed; otherwise 0.15% could be accepted. Alternatively, the accuracy in applying this chemical dose meter was considered improved if there was an independent determination of epsilon with the same spectrophotometer as was used for the determination of the optical density of irradiated Fricke solution. The accuracy claimed for both methods remains questionable, since no complete argumentation could be given for the differences of up to 13% in the published values. Taking into account the discussion of the sources of ...
1977-12-09
Body dose conversion factors for computerized tomography
International Nuclear Information System (INIS)
While there have been many experimental and calculational investigations on absorbed dose distribution in the patient resulting from conventional X-ray procedures, such data for computerized tomography (CT) are still sparse. As this diagnostic procedure has shown a rapid increase in application during recent years, we have determined absorbed dose to body organs in a human phantom resulting from CT examinations. The exposure model consists of the heterogeneous MIRD-5 phantom and a suitable Monte-Carlo method to calculate absorbed dose to organs of interest. The exposure conditions are specified according to the exposure specifications of a CT-scanner currently in use. The calculations cover the range of body tissues of interest in terms of organ absorbed doses as well as a risk weighted absorbed ...
1980-10-31
Dose planning and dose delivery in radiation therapy
International Nuclear Information System (INIS)
A method has been developed for calibration of CT-numbers to volumetric electron density distributions using tissue substitutes of known elemental composition and experimentally determined electron density. This information have been used in a dose calculation method based on photon and electron interaction processes. The method utilizes a convolution integral between the photon fluence matrix and dose distribution kernels. Inhomogeneous media are accounted for using the theorems of Fano and O'Connor for scaling dose distribution kernels in proportion to electron density. For clinical application of a calculated dose plan, a method for prediction of accelerator output have been developed. The methods gives the number of monitor units that has to be given to obtain a certain absorbed dose to a point inside an irregular, inhomogeneous object. The method for ...
2008-08-01
A somatic dose index for diagnostic radiology
International Nuclear Information System (INIS)
Irradiation of the human body in diagnostic X-ray procedures results in different absorbed doses in the various body organs. A somatic dose index in formulated by applying the relative sensitivity of the human to each of the most important somatic effects and utilizing the absorbed dose in the affected organs. This quantity is used to convey a cumulative somatic impact and is computed for common radiographic views in diagnostic radiology as a function of beam quality for a nominal IR entrance exposure. Using typical X-ray beam qualities and exposures, the frequency of the various radiographic views that make up an examination and the frequencies of the various examinations in the national population, illustrative examples of the application of the somatic dose index are presented. (author).
1978-01-01
Electron Beam and Gamma Radiolysis of Solid-State Metoclopramide
British Library Electronic Table of Contents (United Kingdom)
Purpose Study the radiolysis of solid-state metoclopramide hydrochloride at various absorbed doses. Elucidate the structure of the degradation products to gain information on the radiolysis mechanisms. Methods Solid-state metoclopramide samples were irradiated at several doses with gamma rays and high-energy electrons to evaluate the influence of the dose rate. High-performance liquid chromatography with a diode array detector was used to measure the chemical potency as a function of the absorbed dose and to quantify the degradation products. The characterization of degradation products was performed by liquid chromatography/atmospheric pressure chemical ionization/tandem mass spectrometry. Results The degradation of solid-state metoclopramide after irradiation was negligible. No qualitati...
2006-01-01
Preparation of wood-polymer composites using radiation
International Nuclear Information System (INIS)
Wood-polymer composites (WPC) have been prepared of pinewood with different monomers using Gamma radiation: acrylamide, butyl acrylate, butyl methacrylate, styrene, acrylonitrile, and polyester. The polymer loading was determined as a function of monomer concentration and absorbed dose. The data show that polymer loading increases by increasing the monomer concentration. In two cases, BMA and polyester, the polymer loading decreases at high concentrations. This can be explained by the increase of the viscosity. Thus the diffusion of the compound into bulk would be slower. The absorbed dose seems to play a positive role in enhancing the polymer loading by increasing the dose. The mechanical properties, tensile and compression strength, have been improved in the most cases for all monomer concentrations or absorbed doses. Using polyester there ...
1976-11-25
Absorbed dose and dose equivalent depth distributions for protons with energies from 2 to 600 MeV
Energy Technology Data Exchange (ETDEWEB)
Depth dose distributions for protons in the energy range from 2 to 600 MeV have been calculated by Monte Carlo and analytical methods. The dependence on energy of Maximum Dose Equivalent (MDE), quality factor and isotropic factor recommended for practical use are presented. The problems connected with regulation of maximum permissible proton fluxes are discussed. (author).
1989-01-01
Multicellular level dosimetry and low dose rate effects
International Nuclear Information System (INIS)
Building on the concepts of MIRD methods described by Webber, Watson and others at this Symposium on the Dosimetry of Administered Radionuclides, we will now consider how to apply these principles to several experimentally based open-quote macroclose quotes and multicellular models. Specifically, methods to calculate absorbed dose using different types of particulate emission (alpha, beta) with a variety of antibody carriers (IgG, F(ab')_2, Fab) for radioimmunotherapy (RIT) will be reviewed. Additionally, a discussion of direct measurement methods at the multicellular level will reveal the problems of tumor absorbed dose heterogeneity when applied to animal and clinical studies.
1989-09-21
Clinical application of dosimetry in electron beam therapy
International Nuclear Information System (INIS)
In everyday radiotherapy we must carry out the determination of absorbed dose measurement according to JARP's protocol. We explained an outline of JARP's 1974 and 1986 protocol in electron beam therapy, and mentioned it about the matter that should examined. To use it easily in clinic, a simplified procedure based on precisely to JARP's 1986 protocol is practical, the character of this procedure settles briefly the determination of mean incident energy of electron beams and get ready to table of ionization to absorbed dose conversion factor for various ionization chamber. Also, this procedure almost not influence on the accuracy of determination. We described systematically practical procedure for requisite absorbed dose calculation in a patient in electron beam therapy. (author).
Energy Technology Data Exchange (ETDEWEB)
The performance of PAN-based composite absorbers was evaluated in dynamic experiments at flow rates ranging from 25--100 bed volumes (BV) per hour. Composite absorbers with active components of ammonium molybdophosphate (AMP) PAN and K-Co ferrocyanide (KCoFC) PAN were used for separating Cs from a 1 M HNO{sub 3} + 1 M NaNO{sub 3} + 2 {times} 10{sup {minus}5} M CsCl acidic simulant solution. KCoFC-PAN and two other FC-based composite absorbers were tested for separating Cs from alkaline simulant solutions containing 0.01 M to 1 M NaOH and 1 M NaNO{sub 3} + x {times} 10{sup {minus}4} M CsCl. The efficiency of the Cs sorption on the AMP-PAN absorber from acidic simulant solutions was negatively influenced by the dissolution of the AMP active component. At flow rates of 50 BV/hr, the decontamination factor of about 10{sup 3} could be maintained for treatment of 380 BV of the feed. With the KCoFC-PAN ...
1996-05-01
Dosimetry in dental radiology. Dentascan spiral CT versus panoramic radiography
International Nuclear Information System (INIS)
The study compares the doses absorbed by the dentomaxillary area in spiral CT and panoramic examinations. The dose measurements demonstrate that patients receive smaller doses with panoramic radiography than with spiral CT with Dentascan. After following for some variations from instrumental differences, they are in substantial agreement with literature data. Further investigations are needed considering the radiobiological risk related to the growing spread of Dentascan examinations.
1999-05-01
International Nuclear Information System (INIS)
The purpose of this study is to evaluate the accuracy of dose calculations by three algorithms. Depth dose, OPF (Output Factor) and dose profiles were measured in a heterogeneous phantom. These values were also calculated by three algorithms of the Batho power law (BPL), Equivalent-Tissue Air Ratio (ETAR) and Convolution superposition (CS). The data were obtained for 4, 6 and 10 MV photon beams with a linear accelerator (Varian 21EX). Field size ranged from 3 x 3 cm"2 to 10 x 10 cm"2. Dose profiles of beam penumbra were also measured by a 0.125 ml ionization chamber at the point of 8, 13 and 18 cm from the surface of the phantom at intervals of 1 mm. Differences between measured and calculated depth doses were within 2% in BPL and CS, but depth doses were overestimated in ETAR. OPFs were also overestimated with the error of more than 4% in ETAR. ...
2004-12-01
ESR/Alanine dosimetry on Wolsung Unit 1
Energy Technology Data Exchange (ETDEWEB)
Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement result shows extremely ...
2007-07-01
ESR/Alanine dosimetry on Wolsung Unit 1
International Nuclear Information System (INIS)
Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement result shows extremely ...
2007-05-10
Bioavailability of lead in rats fed human diets
International Nuclear Information System (INIS)
The bioavailability of lead was studied in rats fed various baby foods (Babymix-turkey, Babymix-vegetables, Frutolino-fruit, Frutamix-bananas, Babyron-S-26, Truefood), cow's milk, bread, liver and standard rat diet. Lead absorption was determined by measuring the whole body retention of "2"0"3Pb 6 days after a single oral application. Highest absorption values ranging from 17 to 20% were obtained in animals fed cow's milk and fruit foods. Rats on other human diets absorbed between 3 and 8% of the radioactive lead dose. Only in animals on rat diet lead absorption was below 1%. It is concluded that rats fed human diets show absorption values similar to those in humans. This might indicate that the bioavailability of lead is primarily dependent on dietary habits. This experimental model, if confirmed by further work, might be useful for obtaining preliminary data on the bioavailability of metals from various foods.
Medical irradiation and the use of the 'effective dose equivalent' concept
International Nuclear Information System (INIS)
By applying the linear-dose effect relation, the weighting factors for total risks recommended by IRCP can be transformed to weighting factors for somatic effects. Another weighting factor Msub(s) has to be used which takes into account the dependence of the latent period for occurrence of malignant disease and the variation of the incidence with time. On this basis a somatically significant dose equivalent can be defined as 'the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by the various individuals', and an approximation has been derived for this. Tables are presented of the somatic effective dose equivalents calculated for different x-ray examinations for various organs and tissues. The S.E.D. equivalents have also been calculated for ...
1980-03-01
Estimation of X-rays dose in the crystals of final thickness
International Nuclear Information System (INIS)
A calculation method of the X-ray radiation dose (energy of gamma- radiation remains in the range of energies where the mechanism of photoelectric absorption is the prevailing one) absorbed in the absorbers of final thickness is suggested. Calculations of resorption of secondary radiation (characteristic fluorescences) in the substance and kinetic energy of photoelectrons caused by this resorption (it would be enough to consider one or two hard series) are presented. Calculation of the spectrum of photoelectron energy yield in TeInSe_2 monocrystal for 0.1-0.5 A range of X-ray radiation is conducted by the developed methods.
Tertiary-Butanol: A toxicological review
British Library Electronic Table of Contents (United Kingdom)
Tert-Butanol is an important intermediate in industrial chemical synthesis, particularly of fuel oxygenates. Human exposure to tert-butanol may occur following fuel oxygenate metabolism or biodegradation. It is poorly absorbed through skin, but is rapidly absorbed upon inhalation or ingestion and distributed to tissues throughout the body. Elimination from blood is slower and the half-life increases with dose. It is largely metabolised by oxidation via 2-methyl-1,2-propanediol to 2-hydroxyisobutyrate, the dominant urinary metabolites. Conjugations also occur and acetone may be found in urine at high doses. The single-dose systemic toxicity of tert-butanol is low, but it is irritant to skin and eyes; high oral doses produce ataxia and hypoactivity and repeated exposure can induce dependence...
2010-01-01
Alpha-particle dose distribution effects at the cellular level
International Nuclear Information System (INIS)
Ionizing radiations that differ in number, size, and distribution of energy deposition events might be expected to cause different effects for the same absorbed dose. Furthermore, microdosimetry calculations suggest that large variations in biological effectiveness might be expected for internally deposited alpha-emitting radionuclides for the same absorbed dose, depending upon the specific activity and spatial distribution of the sources in tissue. The study described in this article was designed to demonstrate these phenomena in vitro. Cultured Chinese hamster ovary (CHO-K1 BH4) cells were exposed in vitro to inert, insoluble ceramic microspheres in zirconium dioxide labeled with "2"3"9Pu. The average exit energy of the 5.15 MeV alpha particle was calculated to be 4.3 MeV. Exposure times varied from four to seven hours to achieve the desired dose level.
1985-02-01
Mammary carcinogenesis in the rat after low-dose irradiation
International Nuclear Information System (INIS)
Carcinogenesis is now generally recognized to be an important detrimental effect in man after low dose irradiation. The carcinogenic action of ionizing radiation is clearly demonstrated after exposure to relatively high doses (in excess of 0.5 Gy) but for lower dose levels reliable direct observations are not available. With the introduction of special protocols for the performance of large scale screening programs by mammography the average absorbed dose in glandular tissue in the average breast can be restricted to a value of 3 mGy per mammogram. The risk for tumor induction after exposure to these low doses can never be established from human epidemiology. In order to investigate the risk of repeated exposure to small dose of ionizing radiation the induction of mammary tumors has been investigated in rats of the WAG/Rij strain after ...
1992-07-12
The result of Alanine/ESR dosimetry at Wolsung unit 1
International Nuclear Information System (INIS)
It needs accurate estimation of radiation level for verifying machinery and cable in Nuclear Power Plant. Therefore, in this study, we used ESR(Electron Spin Resonance) system for estimate dose of Alanine dosimeter. Alanine/ESR dosimetry, already known as a dosimetric method in medical and industrial field, was applied to estimate dose quantity at cable locations within a nuclear power plant as a part of equipment qualification program. Alanine/ESR dosimetry of absorbed dose range is 1 - 100 KGy. The alanine dosimeter is not significantly affected by temperature and fading is limited to 1% per year. The alanine dosimeters were fixed on the targeted cable or nearest position to measure dose quantity to get accurate value. Alanine dosimeters were scanned by commercially used two different ESR systems, e-scan and EMX series for alanine dosimeters. To estimate more accurate ...
2008-10-01
International Nuclear Information System (INIS)
The decree refers to conditions of irradiation of food and its components for radappertization and radurization using gamma radiation from cobalt 60 or cesium 137, X radiation or electron beam up to maximum total medium absorbed dose 10 kGy.
2003-03-04
28: Calculation of 3D dose distribution for photons in inhomogeneous media
International Nuclear Information System (INIS)
A method for calculation of absorbed dose distributions in three dimensions for 1-20 MeV photons is presented. The method uses convolution/superposition of photon fluence distributions with energy scattering kernels. Results for Co-60 and X-ray beams in homogeneous and inhomogeneous media are compared with measurements. Good agreement is found between calculations and measurements. 8 refs.; 3 figs.
Dosimetry of iodine-123 iomazenil in humans
International Nuclear Information System (INIS)
The distribution of the central benzodiazepine receptor specific ligand iodine-123 iomazenil was investigated in seven human adults from whole-body scans, blood samples and urine collected up to 24 h after injection. Using 12 source organs, the MIRD method was applied to calculate the absorbed radiation dose of the radioligand in various organs. The urinary bladder wall (0.15 mGy/MBq), lower large intestinal wall (0.071 mGy/MBq) testes (0.044 mGy/MBq) and upper large intestined wall (0.038 mGy/MBq) received the highest absorbed doses. The average effective dose equivalent of "1"2"3I-IBZM for adults was estimated to be 0.033 mSv/MBq. (orig.).
Risk of cancer after low doses of ionising radiation: retrospective cohort study in 15 countries
UK PubMed Central (United Kingdom)
Objectives To provide direct estimates of risk of cancer after protracted low doses of ionising radiation and to strengthen the scientific basis of radiation protection standards for environmental,...Full Text Available
2005-07-09
Retrospective individual dosimetry using luminescence and EPR after radiation accidents
International Nuclear Information System (INIS)
In areas where radiation dose monitoring has not been performed, it is essential to use material available in the environment be able to rapidly assess doses to individuals for immediate emergency medical care or for general estimation of the radiological consequences. It was shown that certain types of telephone cards containing microchips have the potential to be used as individual radiation dosimeters in emergency situations to detect doses over 250 mGy by luminescence measurements. In order to understand the dosimetric properties of chip cards, the components obtained from INFINIEON Company at various stages of production were used for luminescence measurements. It is found that the protecting layer used above the chips so called 'globe top' is the main source of radiation induced signal in chip cards. The globe top produced by INFINIEON at that stage is found to contain SiO2 and Epoxy. In order to improve the ...
INTRINSIC DOSIMETRY: A POTENTIAL NEW TOOL FOR NUCLEAR FORENSICS INVESTIGATIONS
International Nuclear Information System (INIS)
Thermoluminescence (TL) dosimetry was used to measure dose effects on the raw stock material of borosilicate container glass from different geographical locations. Effects were studied at times up to 60 days post-irradiation at doses from 0.15 to 20 Gy. The minimum detectable dose using this technique was estimated to be 0.15 Gy which is roughly equivalent to a 24 hr irradiation 1 cm from a 50 ng source of 60Co. Two peaks were identified in the TL glow curve, a relatively unstable peak around 125 C and a more stable peak around 225 C. Differences in TL glow curve shape and intensity were also observed for the glasses from different geographical origins. We investigate radiation induced defects in glass to further develop the technique of intrinsic dosimetry - the measurement of the total absorbed dose received by the walls of a container holding radioactive material. Intrinsic ...
2010-07-11
Coloring of cultured pearls by gamma-rays irradiation
International Nuclear Information System (INIS)
Changing cream pearls into bluish-grey by #gamma# ray irradiation is a technique in coloring of pearls. Irradiated pearls are similar in color to cultured blue pearls. The pearl layers hardly change their color but the nuclei change into dark brown by irradiation. Visible light (500 - 700 nm) penetrating the pearl layer is absorbed by dark brown nucleus. The intensity of reflecting light between 400 and 500 nm at pearl surface, therefore, becomes stronger than that between 500 and 700 nm; therefore color of irradiated pearls look bluish-grey. The density of bluish-grey color increases with increasing absorbed doses, but their luster at surface diminishes owing to the deterioration of the pearl layer by prolonged irradiation; high doses irradiation should be avoided. Irradiated pearls show no substantial fading of their color in a year and the rate of the fading is found to be lower than that for ...
Energy Technology Data Exchange (ETDEWEB)
To date, no single passive detector has been found that measures dose equivalent from ionizing radiation exposure in low-Earth orbit. We have developed the I.S.S. Passive Dosimetry System (P.D.S.), utilizing a combination of TLD in the form of the self-contained Pille TLD system and stacks of CR-39 plastic nuclear track detector (P.N.T.D.) oriented in three mutually orthogonal directions, to measure total dose and dose equivalent aboard the International Space Station (I.S.S.). The Pille TLD system, consisting on an on board reader and a large number of Ca{sub 2}SO{sub 4}:Dy TLD cells, is used to measure absorbed dose. The Pille TLD cells are read out and annealed by the I.S.S. crew on orbit, such that dose information for any time period or condition, e.g. for E.V.A. or following a solar particle event, is immediately available. Near-tissue equivalent CR-39 ...
2006-07-01
International Nuclear Information System (INIS)
Techniques for reducing computation time in 3D photon dose calculations are addressed with specific emphasis given to the convolution/superposition approach. A single polyenergetic superposition model calculating absorbed dose per incident photon fluence (Gy cm"2) was developed in terms of TERMA and a total energy deposition kernel (a total point spread function). A novel approach was devised for reducing calculation time. The method, named the CF method, was based on the use of a conventional, fast model (here a modified power-law method was used) for the generation of 3D dose distributions on a fine dose matrix. Superposition calculations were carried out on a coarse matrix and calculation speed was increased simply by reducing the number of calculations. A set of correction factors was derived on the coarse grid from the ratio of the dose values from ...
1997-08-01
Paediatric radiography - the avoidance of late radiation damage to the growing hip
Energy Technology Data Exchange (ETDEWEB)
Epiphyseal plates of growing bones are sensitive to ionizing radiation and this poses problems for the paediatric radiotherapist. In this case report we describe a child in whom electron beam therapy to the groin delivered only low dose radiation to the proximal hip epiphyses - 130 cGy fractionated over 5 weeks - but who suffered late maldevelopment. We explore the success of various radiotherapy techniques in minimizing the dose to the hip epiphyses in four other children. The appropriate positioning of the limb, the choice of treatment modality and, where possible, individual shielding blocks are considered and their effect on the dose to the hip estimated. Absorbed doses of radiation delivered to the midpoint of the proximal femoral epiphyses have been retrospectively determined. (author).
1993-04-01
Energy Technology Data Exchange (ETDEWEB)
The importance of cellular dosimetry in both diagnostic and therapeutic nuclear medicine is becoming increasingly recognized. Experimental range-energy relations for electrons and alpha particles, along with derived geometric reduction factors, are used to calculate cellular absorbed fractions for these radiations. The resulting absorbed fractions are employed to calculate cellular S-values for several radionuclides. Cellular absorbed fractions for monoenergetic electron sources with energies ranging from 0.1 keV to 1 MeV, distributed uniformly in the source region, are calculated for several target {l_arrow} source combinations including cell{l_arrow}cell, cell{l_arrow}cell surface, nucleus{l_arrow}nucleus, nucleus {l_arrow}cytoplasm and nucleus {l_arrow}cell surface. Similar data are also provided for monoenergetic alpha particle sources with energies ranging from 3 to 10 MeV. S-values are also conveniently tabulated for ...
1994-02-01
The use of calcium silicate bricks for retrospective dosimetry
International Nuclear Information System (INIS)
The suitability of calcium silicate bricks (CSBs) for the retrospective measurement of gamma dose using luminescence techniques has been investigated. Bricks of this type are distinguished from fired clay bricks by containing negligible clay and requiring comparatively low temperature treatment during manufacture. They have been used widely in the construction f buildings in the Former Soviet Union since the 1970s but hitherto have not been used for retrospective dosimetry measurements. A procedure based on the se of the 210 deg. C thermoluminescence (TL) peak of quartz was tested with granular quartz extracted from three types of CSB, one of which had been taken from a settlement downwind of Chernobyl. The degree to which the residual geological TL signal within the temperature range of the 210 deg. C L peak had been reduced during manufacture varied with brick type; the levels of residual TL corresponded, in the samples tested, to absorbed ...
2004-02-01
Radon concentrations and absorbed dose measurements in a Pleistocenic cave
International Nuclear Information System (INIS)
Radon concentration measurements were carried out using solid-state nuclear track-etch detectors (SSNTDs) type CA 80-15 cellulose nitrate films, in a Pleistocenic cave at Petralona, in Halkidiki, Northern Greece, at 55 km from the city of Thessaloniki. Radon levels as high as 88 kBqxm"-"3 (2.38 nCi x l"-"1) have been recorded inside the cave equivalent to 11.90 WL in terms of occupational exposure to radon and its decay products. Absorbed dose rates were performed using TL dosimeters, type TLD-200 (CaF_2-Dy) in a continuous monitoring program (integrated measurements). Dose rate levels as high as 110 nGy x h"-"1 were recorded inside the cave. In interpreting the high levels of radiation doses, radioactivity measurements regarding the naturally occurring "2"3"8U, "2"3"2Th and "4"0K radionuclides were carried out in various speleothems found at different sites in the cave. (author)
2003-10-01
Radiation doses in adults and children in standardized diagnostic radiology
International Nuclear Information System (INIS)
For comparison of radiation exposure and risk in different diagnostic procedures for adults and children dose measurements and calculations of organs with special risk were carried out. Parameters of image formation influencing image quality as well as of exposure concerning infants and children are recorded and discussed as to radiation exposure and protection. Conclusions are drawn with respect to systems of image formation and to standards of examination and quality assurance.
1987-01-01
Dosimetry audit on the accuracy of 192Ir brachytherapy source strength determinations in Sweden
Energy Technology Data Exchange (ETDEWEB)
The absorbed dose delivered to the patient in brachytherapy is directly proportional to the source strength in terms of the reference air-kerma rate (RAKR). Verification of this quantity by the hospitals is widely recognized as an important part of a quality assurance program. An external audit was performed on behalf of the Secondary Standard Dosimetry Laboratory at the Swedish Radiation Protection Authority (SSI). The aim was to investigate how accurately the source-strength in 192Ir brachytherapy is determined at Swedish hospitals. The SSI reference well-type ion chamber and calibrated equipment were used to measure the RAKR of an 192Ir source in each of the 14 Swedish afterloading units. Comparisons with values determined by vendors and hospitals were made. Agreement in values of RAKR as determined by SSI, hospitals and vendors were in all cases within the +-3% uncertainty (at a coverage factor of k=2), typically ...
2007-11-15
Photon dosimetry using plastic scintillators in pulsed radiation fields
Energy Technology Data Exchange (ETDEWEB)
Simulations and experiments have been carried out to explore using a plastic scintillator as a dosimetry probe in the vicinity of a pulsed bremsstrahlung source in the range 4 to 20 MeV. Taking advantage of the tissue-equivalent properties of this detector in conjunction with the use of a fast digital signal processor near real-time dosimetry was shown to be possible. The importance of accounting for a broad energy electron beam in bremsstrahlung production, and photon scattering and build-up, in correctly interpreting dosimetry results at long stand-off distances is highlighted by comparing real world experiments with ideal geometry simulations. Close agreement was found between absorbed energy calculations based upon spectroscopic techniques and calculations based upon signal integration, showing a ratio between 10 MeV absorbed dose to 12 MeV absorbed dose of 0.66 at a distance of ...
2007-04-01
Energy Technology Data Exchange (ETDEWEB)
Methylmethacrylate polymerisation in the presence of 4 wt% butadiene-acrylonitrile rubber was carried out at fixed dose-rate and temperature. The effect of irradiation was investigated with respect to the mechanical and dynamic-mechanical properties in the solid state. A general increase of the 'compatibilisation' on irradiation is obtained. In fact both rubber and polymethylmethacrylate glass transition temperatures, determined through dynamic-mechanical analysis, reveal the presence of strong interactions between the components. Furthermore an improvement of the mechanical tensile properties of the blends is observed when irradiation is continued after polymerisation, at least until a certain absorbed dose.
2001-12-01
Calculated fluence spectra at neutron therapy facilities
International Nuclear Information System (INIS)
The Monte Carlo transport codes LAHET and MCNP were used to calculate energy fluence spectra at three neutron therapy facilities. The results compare very favourably with measured data. Kerma spectra and the ratio of ICRU muscle tissue kerma to A-150 kerma, along the carbon to oxygen kerma ratio, were determined. Absorbed dose rate calculations are in reasonable agreement with measured values. Use of these codes to study modifications to existing therapy beams is briefly discussed. (author).
1995-11-13
Standard radiation monitoring at Sendai nuclear power station
International Nuclear Information System (INIS)
Standard radiation monitoring has been conducted at Sendai nuclear power station for the purpose of estimation of 'source activity' during refueling outage and evaluation of countermeasures to reduce dose rate. Selected objects of the monitoring are radiation dose rate at maintenance area, radiation field at each equipment and piping, coolant chemistry and plant operation condition. Monitored data indicates that 'source activity' variation can be estimated to some extent using influential factors, and that evaluation of change of loose crud activity, which is presumed to be represented by the dose rate at letdown heat exchanger, is necessary to further explain change in radiation field at main work area. (author).
Radiation exposure of the population of the GDR by X-ray diagnostics
International Nuclear Information System (INIS)
The radiation burden of the people of the GDR in relation to biomedical radiography altogether as well as organ doses, gonad doses and genetically significant doses in detail are outlined. The concepts of radiation protection and standards of radiographic examination are demonstrated. Possibilities of influencing radiation exposure by scientifically based indication of X-ray examination, application of new and improvement of usual examination techniques are discussed with regard to quality assurance and control. Proposals concerning the reduction of radiation exposure of the GDR population are presented.
1986-01-01
Comparison of Atmospheric Dispersion Models Between PHWR and PWR
International Nuclear Information System (INIS)
The radiation dose and the atmospheric dispersion for Pressurized Heavy Water Reactors (PHWR) are based on the CAN/CSA N288.2-M91 standards: for Pressurized Water Reactor (PWR) on the NRC Regulatory Guide 1.145. There are some differences between in the methodologies used in the standards, including the atmospheric dispersion model, the release height, the temperature lapse rate, the cutoff condition. This paper reports on a comparison of standards for atmospheric dispersion models of PHWRs and PWRs in order to determine which one is the more conservative. The comparison between PHWR and PWR for atmospheric dispersion factors and radiation doses confirms that there are no big differences
2010-10-01
Primary standardization of {sup 242} Am radioactive sources
Energy Technology Data Exchange (ETDEWEB)
The procedure followed by the Laboratorio de Metrologia Nuclear in Sao Paulo, Brazil, for the standardization of {sup 242g} Am is described. The calibration system was composed of a 4 {pi} gas-flow proportional counter coupled to a pair of NaI(Tl) crystals operating in coincidence. The samples were produced by irradiating dried aliquots of {sup 241} Am with thermal and epithermal neutrons at the IEA-R1 research reactor. The efficiency tracer technique has been applied using {sup 60} Co as tracer. The beta detection efficiency was changed by external absorbers and extrapolated to unity by linear least square fitting applying covariance methodology. (author)
2001-07-01
Energy Technology Data Exchange (ETDEWEB)
Pyrheliometric methods are described (particularly methods for measuring the solar constant), and theoretical and experimental studies in this field are surveyed and systematized. Particular attention is given to the analysis of instruments intended for pyrheliometers used as standards, reference instruments, and solar-constant meters is examined, and consideration is given to methods for determining the thermal-radiation properties of absorbing coatings and methods for calculating the absorption coefficients of cavity receivers.
1981-01-01
CT-Expo - a novel program for dose evaluation in CT
International Nuclear Information System (INIS)
CT-Expo is a novel MS Excel application for assessing the radiation doses delivered to patients undergoing CT examinations, based on computational methods that were used to analyze the data collected in the German survey on CT practice in 1999. The program enables the calculation of all dose quantities of practical value, such as axial dose free-in-air, weighted CTDI, dose-length product, effective dose and uterine dose. In contrast to existing programs for CT dose assessment, CT-Expo offers a number of unique features, such as gender-specific dose calculation for all age groups (adults, children, newborns), applicability to all existing scanner models including correction of scanner-specific influences, and the possibility of comparison with the results from the German CT survey on CT practice. Three different ...
2002-12-01
International Nuclear Information System (INIS)
There are many differences between industrial CT and industrial radiography, such as imaging principle, inspection time, radiation dose and the requirements for operators etc. The national standards for radiation protection of industrial detection are not applicable to the requirements of protection and safety for #gamma#-ray industrial CT to some extent now. In order to standardize the production and use for #gamma#-ray industrial CT, protect the safety of operators and the public, and to promote the popularization and application of #gamma#-ray industrial CT, it is significant to establish the national standards for radiation protection of #gamma#-ray industrial CT as soon as possible. The purpose of this paper is to introduce the contents of this standard, and specify some important terms. Then there is a brief discussion on the existing problems during establishing such ...
2009-03-01
Analysis on Dose Distribution in Heterogeneous Condition for Narrow 6 MV X-ray Beams
International Nuclear Information System (INIS)
Advanced modality of high-precision radiotherapy fulfilled by a composition of large numbers of small field beams called 'beamlets' can be achieved via nonuniform intensity fluencies. In case of radiation measurements and calculations with narrow high-energy photon beams, however, an accurate two-dimensional dosimetry is a challenging task due to dosimetrically unfavorable phenomena such as dramatic changes of the dose at the field boundaries, dis-equilibrium of the electrons resulting from larger detector volume, and non-uniformity between the detector and the phantom materials. Meanwhile, with the advantages of high spatial resolution and wide range of absorbed doses, there is a growing demand of GAFCHROMICat..EBT film to confirm delivered dose distribution. Especially, the effects from the material differences between the phantom and the film can be minimized in the heterogeneous condition since the ...
2010-10-01
Optimization of segment weight using simulated dynamics algorithm for beamlet-based IMRT
International Nuclear Information System (INIS)
With accurate calculation algorithms in inverse planning for beamlet-based intensity modulated radiotherapy (IMRT), it takes time to calculate the dose matrix, which represents the dose distribution of each beamlet element to each voxel for unit fluence. To reduce the calculation time, coarse or approximate algorithms are often a choice, but this results in a final dose distribution that cannot reflect the real value. In addition, it is necessary to test if a coarse algorithm is capable of calculating the dose matrix of beamlets. In this work, simulated dynamics optimization algorithm was applied to optimize the segment weight to minish the dose error from the dose matrix calculation. After calculating the dose matrix by ray-tracing algorithm which takes into account just the primary component of absorbed ...
2007-08-01
Energy Technology Data Exchange (ETDEWEB)
Several short-lived, high-energy beta emitters are being proposed as the radionuclide components for molecular-targeted potential cancer therapeutic agents. The laboratory mice used to determine the efficacy of these new agents have organs that are relatively small compared to the ranges of these high-energy particles. The dosimetry model developed by Hui et al. was extended to provide realistic beta-dose estimates for organs in mice that received therapeutic radiopharmaceuticals containing 90Y, 188Re, 166Ho, 149Pm, 64Cu, and 177 Lu. Major organs in this model included the liver, spleen, kidneys, lungs, heart, stomach, small and large bowel, thyroid, pancreas, bone, marrow, carcass, and a 0.025-g tumor. The study as reported in this paper verifies their results for 90Y and extends them by using their organ geometry factors combined with newly calculated organ self-absorbed fractions from PEREGRINE and MCNP. PEREGRINE and MCNP agree to within 8% ...
2005-08-01
Determinations of organ or tissue doses to survivors in Hiroshima and Nagasaki
International Nuclear Information System (INIS)
For the purpose of risk estimates from radiation carcinogenesis including leukemogenesis and radiation genetic effects, the biological significant dose is not the tissue kerma in air but the absorbed dose in organ or tissue with respect to carcinogenic and leukemogenic effects or genetic effects. In order to estimate organ or tissue dose from the tissue kerma in air, a ratio of the organ or tissue dose to the tissue kerma in air for survivors in Hiroshima and Nagasaki was calculated with the aid of the Snyder's mathematical phantoms constructed so as to simulate the body shape of survivors aged 5, 10 years old and adult at the time of atomic bomb detonations. The ratios were corrected for the angular distribution of atomic bomb radiations, assuming an anisotropic angular distribution for the survivors exposed to the atomic bombs in open air and the isotropic distribution for the ...
1980-01-01
Bomb "1"4C and human radiation burden
International Nuclear Information System (INIS)
Following the publication (Stenhouse and Baxter, Nature; 267:828 (1977)) of the levels of bomb "1"4C and the residence times of carbon in the human body, excess radiation burdens from this radioisotope are evaluated under the assumption that no radiation dose, however small, can be regarded as entirely harmless biologically. The estimated annual absorbed dose attributable to "1"4C both natural and man-made for 1953-1973 and similar predicted figures for 1975-2025 are shown graphically. The cumulated doses to gonads (over 30 yr) and to bone marrow and bone-lining cells (over 60 yr) and also estimates of the biological damage to reproductive cells from "1"4C #beta#-irradiation (30 yr accumulated dose) are presented. It is concluded from both genetic and somatic considerations, that the potential human radiation burden due to artificially produced "1"4C calculated using the assumptions ...
International Nuclear Information System (INIS)
The behaviour of the packaging materials under radiation field has a great importance in radiation processing, because, in most cases, they are finally responsible for the preservation of the beneficent changes achieved in irradiated products. For example, in radiation sterilisation and food irradiation, the packages must preserve the sterilisation, respectively the sanitisation. They must preserve also the physical barrier feature. The radiation effects on plastics were extensively studied in the last decades for nuclear industry and more recently for radiation processing. The two major effects of nuclear radiation on polymeric materials are the degradation and cross-linking. The degradation consists in breaking of macromolecules after interaction with nuclear particles, amplified by the free radicals which persist long periods, especially in crystalline polymers. Oxygen could penetrate the sample and interact with free radicals so that the degradation process continues after the ...
Chemical carcinogenesis: too many rodent carcinogens.
UK PubMed Central (United Kingdom)
The administration of chemicals at the maximum tolerated dose (MTD) in standard animal cancer tests is postulated to increase cell division (mitogenesis), which in turn increases rates of mutagenesis...Full Text Available
1990-10-01
UK PubMed Central (United Kingdom)
This study investigated the effect of copper as an antibacterial agent on the infectivity of Salmonella enterica serovar Typhimurium. Mice were infected orally with a standardized dose...Full Text Available
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Faced with increasing indications for the use of iodine-131 labelled lipiodol in the treatment of hepatocellular carcinoma (HCC), it appears essential to develop an individualized dosimetrY so we can predict the potential effectiveness of this treatment and adjust the activity to be injected. We developed a dosimetric protocol based on imagery and dedicated to calculation of the tumoral dose during the treatment of hepatocellular carcinoma by iodine-131 labelled lipiodol. This concept was developed on a SPECT- CT gantry, and integrates corrections for the phenomena of attenuation, diffusion and dead time. The dose is calculated according to the formalism proposed by the Medical Internal Radiation Dose Committee (MIRD). This protocol was applied to a series of 41 patients in the framework of a retrospective study. The results obtained in terms of biodistribution are compatible with previously published data. The total ...
2006-12-15
Energy Technology Data Exchange (ETDEWEB)
Graft copolymerization of sodium styrene sulfonate (SSS) onto electron beam (EB) irradiated poly(vinylidene fluoride) (PVDF) films was investigated to find out a simple preparation process for sulfonic acid proton exchange membranes with respect to monomer concentration, absorbed dose, temperature, film thickness and storage time. The reaction order of the monomer concentration and absorbed dose of grafting was found to be 2.84 and 1.20, respectively. The overall activation energy for graft copolymerization reaction was calculated to be 11.36 kJ/mol. The initial rate of grafting was found to decrease with an increase in the film thickness. The trapped radicals in the irradiated PVDF films remained effective in initiating the reaction without considerable loss in grafting level up to 180 days, when stored under -60 {sup o}C. The presence and distribution of polystyrene sulfonate grafts in the obtained ...
2011-01-15
EPR investigation of some traditional oriental irradiated spices
International Nuclear Information System (INIS)
The 9.50 GHz electron paramagnetic resonance (EPR) spectra of unirradiated and "6"0Co #gamma#-ray irradiated cardamom (Elettaria cardamomum L. Maton, Zingiberaceae), ginger ((Zingiber officinale Rosc., Zingiberaceae), and saffron (Crocus sativus L., Iridaceae) have been investigated at room temperature. All unirradiated spices presented a weak resonance line with g-factors around free-electron ones. After #gamma#-ray irradiation at an absorbed dose of up to 11.3 kGy, the presence of EPR spectra whose amplitude increase monotonously with the absorbed dose has been noticed with all spices. A 100 "oC isothermal annealing of 11.3 kGy irradiated samples has shown a differential reduction of amplitude of various components that compose initial spectra, but even after 3.6 h of thermal treatment, the remaining amplitude represents no less then 30% of the initial ones. The same peculiarities have been noticed ...
2007-06-01
EPR investigation of some irradiated traditional oriental spices
International Nuclear Information System (INIS)
The X-band EPR spectra of unirradiated and "6"0 Co gamma ray irradiated cardamom (Elettaria cardamomum L. Maton, Zingiberaceae), ginger ((Zingiber officinale Rosc., Zingiberaceae), saffron (Crocus sativus L., Iridaceae), and curry have been investigated at room temperature. All unirradiated spices presented a weak resonance line with g-factors around free-electron ones, most probably due to the presence of semiquinones, previously reported to have paramagnetic properties. After gamma ray irradiation at absorbed dose up to 11.3 kGy we have noticed in all spices the presence of complex EPR spectra consisting of a superposition of at last two different paramagnetic species whose amplitude increase monotonously with the absorbed dose. A 100 deg. C isothermal annealing of 11.3 kGy irradiated samples has shown a differential reduction of amplitude of various components that form the initial spectra, but even ...
2005-09-13
International Nuclear Information System (INIS)
Concentrations of 226Ra, 232Th, and 40K measured in bauxite waste, local building materials, and soils are presented and used in model equations to estimate the effective gamma dose-equivalent increments over background in the center of a standard-sized room in a prototype house. Calculated and measured values compare reasonably well.
Fluence-convolution broad-beam (FCBB) dose calculation
International Nuclear Information System (INIS)
IMRT optimization requires a fast yet relatively accurate algorithm to calculate the iteration dose with small memory demand. In this paper, we present a dose calculation algorithm that approaches these goals. By decomposing the infinitesimal pencil beam (IPB) kernel into the central axis (CAX) component and lateral spread function (LSF) and taking the beam's eye view (BEV), we established a non-voxel and non-beamlet-based dose calculation formula. Both LSF and CAX are determined by a commissioning procedure using the collapsed-cone convolution/superposition (CCCS) method as the standard dose engine. The proposed dose calculation involves a 2D convolution of a fluence map with LSF followed by ray tracing based on the CAX lookup table with radiological distance and divergence correction, resulting in complexity of O(N"3) both spatially and temporally. This simple ...
2010-12-07
International Nuclear Information System (INIS)
A number of procedures in diagnostic radiology and cardiology make use of long exposures to x-rays from fluoroscopy units. Although numerous studies have been performed to measure or calculate skin dose from these procedures, there have only been a handful of studies to determine the dose to the other organs. This thesis was focused on devising a method to calculate the absorbed dose to underlying tissues and organs. The work was performed in several stages. First, a commercial convolution/superposition-based treatment planning system used in radiation oncology was modified and complemented to make it usable with the low energies of x-rays used in diagnostic radiology. This required generation of energy deposition kernels in the kilovoltage energy range. The kernels were generated using the EGS4 Monte Carlo system of codes and added to the treatment planning system. The treatment planning system was ...
2001-03-01
Energy Technology Data Exchange (ETDEWEB)
Gel dosimetry is a new dosimetry method applied in radiation therapy. Gel dosimeters consist of a radiation sensitive gel, which can integrate absorbed doses from several radiation sources or beams. The dose to the gel can be evaluated by magnetic resonance imaging (MRI), a procedure that is the focus of the present thesis. A robust tool for the evaluation of the nonuniformity in MRI has been developed, the Deviation Image method. Unlike previously presented methods, the Deviation Image method includes all nonuniformity variations across a phantom surface and is insensitive to stochastic noise. Methods for the estimation of stochastic noise were analyzed in terms of sensitivity to nonuniformities. A method that averages the stochastic noise level over five regions over the phantom surface, and a method that assesses the stochastic noise level from the background, were found to be the methods of choice. Pronounced MR image ...
2001-03-01
Thermoluminescent (Tl) dosimetry of slow-neutron fields at radiotherapy dose level
Energy Technology Data Exchange (ETDEWEB)
The dosimetry for radiotherapy involving neutrons is very complicated, owing to the complexity of secondary radiation components, whose contributions to the total absorbed dose have to be discriminated, owing to the different radiobiological effects. In order to separate thermal neutrons and photons, LiF dosimeters are mostly utilized. containing different percentage of Li, like as TLD-700, TLD-100 and TLD-600, but many problems arise. In the response of TLD-700 exposed to neutron-gamma mixed fields with high neutron flux, the contribution of thermal neutrons to the Tl emission is high. Moreover. TLD-100 and TLD-600 may undergo radiation damage, and great care has to be taken in order to obtain reliable results. Other TLDs showing lower sensitivity to neutrons are proposed and experimented for such high-flux neutron fields. The faced problems and various proposed solutions are here described. (Author)
2003-07-01
Somatic and genetic radiation exposure of the patient in digital subtraction angiography (DSA)
International Nuclear Information System (INIS)
The somatic and genetic radiation exposure of patients undergoing Digital Subtraction Angiography (DSA) and traditional Film Arteriography (FA) of cranial, cervical, thoracic and abdominal vascular territories are compared. The radiation doses absorbed within the critical organs - red bone marrow, lung, thyroid gland and female breast - and in the gonads were measured using an anthropomorphic Alderson phantom. A Somatic Dose Index was calculated in order to estimate the somatic radiation risk. The somatic radiation exposure depends upon the location of the critical organs with respect to the entrance site of the x-ray beam, and can be reduced by an appropriate choice of the angiographic projection. Under this condition, the radiation exposure of the patient during DSA can be lower than during FA. For renal DSA an a.p. projection, the use of an abdominal compression device and careful caudal shielding of the field are ...
1986-01-01
International Nuclear Information System (INIS)
The MCNPE-BO and MCNP4 Monte Carlo electron-photon codes were used to calculate the dose equivalent per unit fluence at various depths in tissue-equivalent slab phantoms for broad parallel beams of monoenergetic electrons with energies from 50 keV to 10 MeV. The study was carried out in the framework of the activities of a ICRP/ICRU Joint Task Group with the support of EURADOS WG4 (Numerical Dosimetry). Some preliminary results and comparisons as well as a general discussion on the performances of the codes are presented, demonstrating quite a satisfactory agreement among the results obtained using the two codes and those of other authors. (author).
Chemical Analysis of Solid-State Irradiated Human Insulin
British Library Electronic Table of Contents (United Kingdom)
Purpose To study the chemical modifications induced upon irradiation of solid human insulin at radiosterilization doses and investigate the influence of the absorbed dose on radiolysis. Materials and Methods Volatile radiolytic products were monitored by gas chromatography coupled with mass spectrometry (GC-MS) and non-volatile products by two different high performance liquid chromatography (HPLC) methods: the formation of higher molecular weight proteins was assessed by size exclusion liquid chromatography whereas assays for related compounds and chemical potency tests were carried out using reverse-phase HPLC-UV. Conformational changes were investigated by measurements of circular dichroism. Results After gamma irradiation at 10?kGy, the recovery of insulin was 96.8%; higher molecular w...
2006-01-01
Radionuclide Air Emissions Report for the Hanford Site Calendar year 1998
Energy Technology Data Exchange (ETDEWEB)
This report documents radionuclide air emissions from the Hanford Site in I998 and the resulting effective dose equivalent to the maximally exposed individual (MEI) member of the public. The report has been prepared in accordance with the Code of Federal Regulations, Title 40, Protection of the Environment, Part 61, National Emission Standards for Hazardous Air Pollutants (40 CFR SI), Subpart H, ''National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities,'' and with the Washington Administrative Code Chapter 246-247, Radiation Protection--Air Emissions. The federal regulations in 40 CFR 61, Subpart H; require the measurement and reporting of radionuclides emitted from Department of Energy facilities and the resulting offsite dose from those emissions. A standard of 10 mrem/yr effective ...
1999-06-15
Lead and calcium distributions in blood, plasma, and milk of the lactating mouse
Energy Technology Data Exchange (ETDEWEB)
Although it has been established that lead is transferred in milk from mother to suckling offspring, the physiological processes and parameters involved are not well understood. Single i.v. doses (0.2 mg/kg) or p.o. doses (2 mg/kg) of radiolabeled lead were administered to lactating and nonlactating female mice, and lead concentrations in blood, plasma, and milk were determined during a 21-day period. Large differences in lead elimination were observed between lactating and nonlactation mice. A significant fraction (25%) of the initial maternal dose (absorbed dose) was transferred to the suckling pups. The ratio of lead concentration in milk to lead concentration in plasma was found to be nearly constant over time. However, the milk-to-blood concentration ratios decreased during the same period. Furthermore, the concentration of lead in milk exceeded the plasma concentration by a ...
1980-01-01
International Nuclear Information System (INIS)
Recent research findings of epidemiologist Alice Stewart suggest that nuclear workers may be at risk of contracting cancer even though their measured occupational doses fall within current safety standards. It is argued that these standards are inappropriate as they are based on extrapolations of studies on survivors of the Hiroshima and Nagasaki explosions. These individuals received single doses of radiation, whereas today's nuclear industry personnel are exposed to low-level ionizing radiation over the length of their working lives. Stewart's team linked low dose occupational exposure to ionizing radiation with an increased risk of cancer in respiratory, digestive and blood-forming tissues. The nuclear industry and United States government agencies hotly contest these assertion with their potentially damaging political and economic consequences. (UK).
1993-05-01
Energy Technology Data Exchange (ETDEWEB)
Recent research findings of epidemiologist Alice Stewart suggest that nuclear workers may be at risk of contracting cancer even though their measured occupational doses fall within current safety standards. It is argued that these standards are inappropriate as they are based on extrapolations of studies on survivors of the Hiroshima and Nagasaki explosions. These individuals received single doses of radiation, whereas today's nuclear industry personnel are exposed to low-level ionizing radiation over the length of their working lives. Stewart's team linked low dose occupational exposure to ionizing radiation with an increased risk of cancer in respiratory, digestive and blood-forming tissues. The nuclear industry and United States government agencies hotly contest these assertion with their potentially damaging political and economic consequences. (UK).
1993-05-15
International Nuclear Information System (INIS)
Convolution/superposition (C/S) is regarded as the standard dose calculation method in most modern radiotherapy treatment planning systems. Different implementations of C/S could result in significantly different dose distributions. This paper addresses two major implementation issues associated with collapsed cone C/S: one is how to utilize the tabulated kernels instead of analytical parametrizations and the other is how to deal with voxel size effects. Three methods that utilize the tabulated kernels are presented in this paper. These methods differ in the effective kernels used: the differential kernel (DK), the cumulative kernel (CK) or the cumulative-cumulative kernel (CCK). They result in slightly different computation times but significantly different voxel size effects. Both simulated and real multi-resolution dose calculations are presented. For simulation tests, we use arbitrary kernels and ...
2005-02-21
Energy Technology Data Exchange (ETDEWEB)
The purpose was to evaluate low-dose CT colonography without cathartic cleansing in terms of image quality, polyp visualization and patient acceptance. Sixty-one patients scheduled for colonoscopy started a low-fiber diet, lactulose and amidotrizoic-acid for fecal tagging 2 days prior to the CT scan (standard dose, 5.8-8.2 mSv). The original raw data of 51 patients were modified and reconstructed at simulated 2.3 and 0.7 mSv levels. Two observers evaluated the standard dose scan regarding image quality and polyps. A third evaluated the presence of polyps at all three mSv levels in a blinded prospective way. All observers were blinded to the reference standard: colonoscopy. At three times patients were given questionnaires relating to their experiences and preference. Image quality was sufficient in all patients, but significantly lower in the cecum, sigmoid and ...
2007-12-15
PURPOSE: To determine the recommended dose of radiotherapy when combined with full-dose gemcitabine and erlotinib for unresected pancreas cancer. METHODS AND MATERIALS: Patients with unresected pancreatic cancer (Zubrod performance status 0-2) were eligible for the present study. Gemcitabine was given weekly for 7 weeks (1,000 mg/m(2)) with erlotinib daily for 8 weeks (100 mg). A final toxicity assessment was performed in Week 9. Radiotherapy (starting at 30 Gy in 2-Gy fractions, 5 d/wk) was given to the gross tumor plus a 1-cm margin starting with the first dose of gemcitabine. A standard 3 plus 3 dose escalation (an additional 4 Gy within 2 days for each dose level) was used, except for the starting dose level, which was scheduled to contain 6 patients. In general, Grade 3 or greater gastrointestinal toxicity was considered a ...
2011-05-01
TRIGA reactor spent fuel pool under severe earthquake conditions
International Nuclear Information System (INIS)
Supplemental criticality safety analysis of a pool type storage for TRIGA spent fuel at 'Jozef Stefan' Institute in Ljubljana, Slovenia, is presented. Previous results (Ravnik, M, Glumac, B., 1996) have shown that subcriticality is not guaranteed for some postulated accidents. To mitigate this deficiency, a study was made about replacing a certain number of fuel elements in the rack with absorber rods (Glumac, B., Ravnik, M., Logar, M., 1997) to lower the supercriticality probability, when the pitch is decreased to contact (as a consequence of a severe earthquake) in a square arrangement. The criticality analysis for the hexagonal contact pitch is presented in this paper, following the same scenario as outlined above. The Monte Carlo computer code MCNP4B with ENDF-B/VI library and detailed three dimensional geometry was used. First, the analysis about the influence of the number of triangular fuel piles on the bottom that could appear, if the fuel rack, made of ...
1998-07-01
Energy Technology Data Exchange (ETDEWEB)
This study evaluates the effect of gamma radiation on the viability of fungi and actinomycetes that contaminate medicinal plants. The relationship between the total lipids of some fungi and actinomycetes and their sensitivity to gamma radiation is also investigated. The data reveal that the viable counts of these florae decrease approximately exponentially with the radiation dose, the effective dose for the elimination of these microorganisms being about 5 kGy for all the medicinal plants under study. Response of pure cultures of fungi and actinomycetes isolated from medicinal plants to increasing absorbed doses of gamma radiation indicate that an increase in radioresistance is in the following order: Streptomyces rimosus, Fusarium solani, Nocardia kuroishii. F. oxysporum, A. fumigatus, A. flavus, A. parasiticus and A. ochraceus. The total lipid contents of molds and actinomycetes have been reported to ...
1997-01-01
Energy Technology Data Exchange (ETDEWEB)
The study compares the doses absorbed by the dentomaxillary area in spiral CT and panoramic examinations. The dose measurements demonstrate that patients receive smaller doses with panoramic radiography than with spiral CT with Dentascan. After following for some variations from instrumental differences, they are in substantial agreement with literature data. Further investigations are needed considering the radiobiological risk related to the growing spread of Dentascan examinations. [Italian] Questo lavoro intende confrontare le dosi assorbite nel distretto dento-mascellare, con le due principali tecniche utilizzate in questo campo: TC spirale e ortopantomografia. Emerge come l'esame panoramico delle arcate dentarie eseguito con l'ortopantomografo comporti la'ssorbimento di dosi inferiori rispetto a quelle dell'esame TC spirale con programma Dentascan. Questi dati, ...
1999-05-01
International Nuclear Information System (INIS)
Dairy products doubly labeled with 45Ca and 47Ca were used to evaluate an extrinsic labeling procedure for calcium bioavailability determination. Nonfat milk, yogurt, and fresh cheese curd were prepared from caprine milk that was intrinsically labeled with 45Ca. The products were then labeled extrinsically with 47Ca and administered to rats by gavage. The 47Ca to 45Ca ratio in bone and teeth averaged about 1.00 with either milk, yogurt, or CaCl2, but the ratio was about 1.04 when dosed with cheese curd. Ca absorption, determined by whole-body counting of 47Ca, was lower (P less than 0.05) in cheese curd (59%) than in either milk (69%), yogurt (72%), or CaCl2 (72%). Expressed as percent of dose, the absorption of 47Ca was highly correlated with bone 47Ca (r = 0.973) and with bone 45Ca (r = 0.946). Correlation between tibia 47Ca and tibia 45Ca was r = 0.923. For the dairy products tested, our results indicated that extrinsic 47Ca was ...
Ultraviolet radiation in Finland
Energy Technology Data Exchange (ETDEWEB)
Solar ultraviolet radiation is damaging for living organisms due to its high energy pro each photon. The UV radiation is often separated into three regions according to the wavelength: UVC (200-280 nm), UVB (280-320 nm) and UVA (320-400 nm). The most hazardous part, UVC is absorbed completely in the upper atmosphere by molecular oxygen. UVB radiation is absorbed by atmospheric ozone partly, and it is reaching Earth`s surface, as UVA radiation. Besides atmospheric ozone, very important factors in determining the intensity of UVB radiation globally are the solar zenith angle and cloudiness. It may be calculated from global ozone changes that the clear-sky UVB doses may have enhanced by 10-15 % during spring and 5-10 % during summer at the latitudes of Finland, following the decrease of total ozone between 1979-90. The Finnish ozone and UV monitoring activities have become a part of international activities, especially the EU ...
1996-12-31
International Nuclear Information System (INIS)
the cotton leaf worm, Spodoptera littoralis (boisd.) were irradiated with 100,150 and 200 Gy to induce inherited sterility. the effects of the tested doses applied to these pupae through three consequent fillial generations and the retarded influence on their F_1,F_2 and F_3 generations progeny were examined . irradiation of parental male induced damage to their daughter females ovaries. the overioles of females among P_1 ,F_1 and F_2 generations showed that the follicular epithelial cells appeared abnormal beside their limited separation from developing oocytes which became shrinked, semi absorbed or completely absorbed leaving vacuoles. the nurse cells were reduced or absent in some parts. damage was obvious through the first and second generations especially at 150 and 200 Gy. in the third generation, ovaries were not greatly affected
2004-02-01
International Nuclear Information System (INIS)
Magnetic particles (MAG*SEP"S"M) coated with various absorbents were evaluated for the separation and recovery of low concentrations of cesium from nuclear waste solutions. The MAG*SEP"S"M particles were coated with (1) clinoptilolite, (2) transylvanian volcanic tuff, (3) resorcinol formaldehyde, and (4) crystalline silico-titanate, and then were contacted with a Hanford supernatant simulant. Particles coated with the crystalline silico-titanate were identified by Bradtec as having the highest capacity for cesium removal under the conditions tested (variation of pH, ionic strength, cesium concentration, and absorbent/solution ratio). The MAG*SEP"S"M particles coated with resorcinol formaldehyde had high distribution ratios values and could also be used to remove cesium from Hanford supernant simulant. Gamma irradiation studies were performed on the MAG*SEP"S"M particles with a gamma dose equivalent to 100 cycles of use. ...
1994-05-09
Pharmacokinetic and dosimetric characteristics of some thallium isotopes
International Nuclear Information System (INIS)
Pharmacokinetics is studied, radiation doses to patients when using domestic thallium-201 chloride in diagnosis of the heart ischemic disease is estimated; contribution into the total dose of thallium-201 (1.5 %), thallium-201 (0.2 %) and lead-201 + lead-203 (0.05 %) radionuclide impurities is also determined. Internal doses were estimated for a heterogeneous phantom of a standard man; the calculations were carried out using a computer. Scanning of patients which were treated with radiopharmaceuticals to be diagnosed was carried out using a whole body counter and gamma-chamber. Large intestine, kidneys and thyroid are the critical organs when using thallium-201 chloride. The highest contribution into the dose to organs and the whole body from thallium-200 and thallium-202 impurities being contained in thallium-201, doesn't exceed 8.6 %. The contribution into the ...
International Nuclear Information System (INIS)
It is very well known that the CANDU reactor has positive Coolant Void Reactivity (CVR), which is most important criticisms about CANDU. The most recent innovations based on using a thin absorbent Hafnium shell in the central bundle element were successfully been applied to the Advanced CANDU Reactor (ACR) project. The paper's objective is to analyze elementary lattice cell effects in applying such methods to reduce the CVR. Three basic fuel designs in their corresponding geometries were chosen to be compared: the ACR-1000TM, the RU-43 (developed in INR Pitesti) and the standard CANDU fuel. The bundle geometry influence on void effect was also evaluated. The WIMS calculations proved the Hafnium absorber suitability (in the latest 'shell design') to achieve the negative CVR target with great accuracy for the ACR-1000 fuel bundle design than for the other two projects. (authors)
2009-05-27
Can photo-ionization explain the decreasing fraction of X-ray obscured AGN with luminosity?
Chandra and XMM surveys show that the fraction of obscured AGN decreases rapidly with increasing luminosity. Although this is usually explained by assuming that the covering factor of the central engine is much smaller at luminous QSOs, the exact origin of this effect remains unknown. We perform toy simulations to test whether photo-ionisation of the obscuring screen in the presence of a strong radiation field can reproduce this effect. In particular, we create X-ray spectral simulations using a warm absorber model assuming a range of input column densities and ionization parameters. We fit instead the simulated spectra with a simple cold absorption power-law model that is the standard practice in X-ray surveys. We find that the fraction of absorbed AGN should fall with luminosity as $L^{-0.16\\pm0.03}$ in rough agreement with the observations. Furthermore, this apparent decrease in the obscuring material is consistent with ...
2008-01-01
British Library Electronic Table of Contents (United Kingdom)
Abstract BACKGROUND: Nitrate leaching and the resulting groundwater contamination from intensive cereal production has become a major concern for long-term farmland efficiency and environmental sustainability in northern China. The aim of this study was to evaluate a water-saving super-absorbent polymer (SAP) for minimising NO3- leaching from soil and optimising corn growth and yield. Thirty-six undisturbed soil lysimeters were installed in a field lysimeter facility in drought-affected northern China to study the growth and yield characteristics of summer corn (Zea mays L.) as well as the amount of NO3-leaching losses under different fertiliser (standard, medium or 75% and low, or 50% of conventional fertilisation rate) and SAP (control, 0; level-1, 15 kg ha-1 and level-2, 30 kg ha-1) tre...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Purpose: calculation of conversion coefficients for the reconstruction of organ doses from entrance doses for abdomen radiographs of 0, 1, 5, 10, 15, and 30-year-old patients in conventional pediatric radiology for the radiographic settings recommended by the German and European guidelines for quality management in diagnostic radiology. Materials und method: using the commercially available personal computer program PCXMC developed by the Finnish Center for Radiation and Nuclear Safety (Saeteilyturvakeskus STUK), conversion coefficients for conventional abdomen radiographs were calculated performing Monte Carlo simulations in mathematical hermaphrodite phantom models describing patients of different ages. The possible clinical variation of beam collimation was taken into consideration by defining optimal and suboptimal radiation fields on the phantoms' surfaces. Results: conversion coefficients for the reconstruction of organ does in ...
2009-10-15
International Nuclear Information System (INIS)
Full text: Optically stimulated luminescence (OSL) dating of individual sand-sized grains of quartz has advanced significantly over the past decade opening up new vistas in luminescence geochronology. Today, single-grain OSL dating can be used to constrain the burial ages of many deposits, including fluvial sediments, glaciofluvial material and archaeological sediments. It also provides a means of examining the stratigraphic integrity of archaeological sites where sediment mixing might have occurred. An OSL age is calculated by dividing the burial dose (the dose absorbed by the grain since it was last exposed to sunlight) by the environmental dose rate (the rate of supply of ionizing radiation to the grain over the period of burial). To obtain reliable OSL ages, therefore, an accurate estimate of the dose rate is required for each sample. Here we describe our OSL dating campaign at ...
2008-04-13
Energy Technology Data Exchange (ETDEWEB)
Apoptosis is a pattern of cell death involving nuclear pycnosis, cytoplasmic condensation, and karyorrhexis. Apoptosis induced by continuous irradiation with gamma rays (externally given by a 137Cs source) or with beta rays (from tritiated water injected ip) was quantified in the crypts of two portions of mouse bowel, the small intestine and descending colon. The time-course change in the incidence of apoptosis after each type of radiation could be explained on the basis of the innate circadian rhythm of the cells susceptible to apoptotic death and of the excretion of tritiated water (HTO) from the body. For 6-h continuous gamma irradiation at various dose rates (0.6-480 mGy/h) and for 6 h after injection of HTO of various radioactivities (0.15-150 GBq per kg body wt), the relationships between dose and incidence of apoptosis were obtained. Survival curves were then constructed from the curves for dose vs incidence of ...
1989-04-01
International Nuclear Information System (INIS)
The utilization of the Ellis-formula for the determination of the tolerance of normal connective tissue is described. Beyond this, the formula is adapted to so-called critical organs. The individual suppositions implicated by the Ellis-formula are commented. Because of the verifyable congruency of the Ellis-formula with data obtained in clinical practice also by other authors, this conception is presented for the provisional determination of the limits of tolerance of normal tissue together with a computerized programme elaborated for use in different therapeutic techniques. (orig.).
1976-01-01
International Nuclear Information System (INIS)
In the early period after the Chernobyl accident, analysis of patterns of "1"3"1I exposure of the human thyroid showed that contaminated milk was the basic source of "1"3"1I intake among the inhabitants of Russia. The equipment and techniques used for measurement of the "1"3"1I content in the thyroids of these individuals are described in this work. A model of the "1"3"1I intake, taking into account protective actions, and a method of thyroid dose calculation are discussed. The mean thyroid dose and frequency distributions of the thyroid doses to inhabitants of towns and villages of the Bryansk, Tula and Orel regions of Russia are presented. The mean dose to the thyroids of children living in the villages was 2 to 5 times higher than the dose to adult thyroids; for children living in the towns, the mean dose was 1.5 to 12 times higher. The mean thyroid mass in ...
Report of the IPSM working party on low- and medium-energy x-ray dosimetry
Energy Technology Data Exchange (ETDEWEB)
New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).
1991-08-01
Report of the IPSM working party on low- and medium-energy x-ray dosimetry
International Nuclear Information System (INIS)
New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).
1991-01-01
Energy Technology Data Exchange (ETDEWEB)
It was developed a new formulation of macro aggregates of Samarium 153 ({sup 153} Sm-MH) for the arthropaties treatment. The radio pharmaceutic was prepared by reaction of Samarium 153 chloride (SmCl{sub 3}) in aqueous environment with sodium boron hydride in NaOH 0.5 N. The microscopic analysis shown that the particles have an average size of 4% m (range 1-14 {mu} m). The velocity of sedimentation was 0.008 cm/min with high stability in vitro in human serum. The biological studies in healthy rabbits, shown that the complex is retained inside the articulation still eight days after of the administration of the radiopharmaceutical. Likewise, it is presented the data of absorbed dose in the different target organs, which was determined by thermoluminescent dosimetry (TLD) through the use of a REMCAL phantom (radiation equivalent manikin calibration). (Author)
1999-07-01
Irradiation of polyethylene in the presence of antioxidants
International Nuclear Information System (INIS)
The radiation induced reactions in LDPE in the presence of phenolic type antioxidants have been studied. It was shown that various antioxidants can influence the polyethylene network formation and the radical yield in different ways. The dependence of network structure on absorbed doses was determined by gel analysis, hot-set test and extraction of antioxidants for samples irradiated with accelerated electrons. It was found that the antioxidants eluted from polyethylene in higher percentage influence polymer crosslinking to a smaller degree. The ESR studies of #gamma#-irradiated blends of polyethylene with antioxidant indicate the presence of alkyl and phenoxyl radicals. The role of antioxidant molecules on radiation induced reactions in polyethylene-antioxidant systems is considered. The correlation between the network structure and the type of additive in polyethylene is also discussed. (author).
Energy Technology Data Exchange (ETDEWEB)
With the exception of the 1945 Hiroshima and Nagasaki nuclear weapon explosions and the 1986 Tchernobyl reactor accident, most of the radiation accidents concerns the medical and the traditional industrial sectors. The seriousness of the accident is directly function of the absorbed dose. The paper, first, gives the definition of a radiologic accident with its specific criteria and pathological manifestations. Then, some famous historical accidents are reviewed from the discovery of X-rays to recent acute irradiations due to the careless manipulation of radiation sources. From this analysis, three main causes are put forward: the dysfunction of nuclear medicine apparatuses, the victims` lack of training and knowledge of the risks, and the non-identification or the loss of radiation sources. (J.S.). 1 photo.
1996-04-01
CSSX Radiolytic H2 Generation ("Thermolysis") -- Final Report
Energy Technology Data Exchange (ETDEWEB)
The purpose of this work was to determine the radiolytic hydrogen gas yield of irradiated CSSX solvent at several temperatures. The active ingredient of this solvent is calix[4]arene-bis-(t-octylbenzo) crown-6, a calixarene crown ether used for cesium complexation. The solvent also contains 1-(2,2,3,3-tetrafluoropropoxy)-3-(4-sec-butylphenoxy)-2-propanol, a fluorinated alcoholic solvent modifer used to improve the solubility of the calixarene and its cesium complex in the Isopar L diluent. Isopar L is a branch-chain alkane and comprises most of the mixture. Samples of this solution were irradiated to various absorbed ?-ray doses in gas-tight sample containers, which were then sampled for hydrogen gas content. The methods are described below.
2009-01-01
A TLD powder dosimetry measurement system for physical models of reference man
International Nuclear Information System (INIS)
A tissue-equivalent dosimetry system has been developed for use in absorbed dose determinations with physical models of Reference Man. The dosimeter used was a thermo-luminescent dosimeter (TLD) powder which was mixed with a 'tissue-equivalent' material and modeled to closely approximate an organ's geometry and absorption properties. A separation procedure was developed by which the TLD powder was washed and the 'tissue-equivalent' material, a wax, was dissolved and extracted following the irradiation of the model. The procedure was tested to determine losses of powder, homogeneity of the powder's distribution throughout the wax, the effects of the separation procedure upon the powder and the statistical behavior of the procedure. The results of these tests established the feasibility of the procedure. A full-scale model of the pancreas was tested and the results supported the validity of the technique. (author)
1978-12-01
Measurement of skin dose in primary irradiation of maxillary sinus carcinoma
Energy Technology Data Exchange (ETDEWEB)
Subcutaneous involvement frequently occurs in maxillary sinus carcinoma. Radical resection does not include removal of the skin at risk. In standard postoperative wedge-pair treatment plans, the surface dose is dependent upon beam weighting, beam energy, and patient contour. Thermoluminescent dosimetry (TLD) measurements were performed to evaluate the surface dose of patients undergoing postoperative irradiation of maxillary sinus carcinoma following primary resection. When 60 Gy was delivered to isocenter with a 45 degrees wedge pair and 6 MV photons with 1 cm bolus, the subcutaneous tissues at risk received {approximately} 30 Gy. Based upon presented TLD measurements, supplemental electron beam therapy to the subcutaneous tissues if primarily involved should be considered.
1991-03-01
A comparison of patient doses in lumbar spine radiography from various X-ray units in Poland
Energy Technology Data Exchange (ETDEWEB)
A number of diagnostic X-ray units in Poland were subjected to analysis. The air kerma on X-ray tables was measured for the X-ray parameters used routinely during lumbo-sacral spine radiography of standard adult patient. Measurements of air kerma were performed using TLD made of lithium-fluoride. The doses received by patients in different X-ray departments can differ more than two orders of magnitude (from 0.42 mGy up to 72.11 mGy), for the same X-ray examination. The dose can be significantly reduced if fluorescent screens made from components of rare earth are used. (author). 10 refs, 1 fig., 2 tabs.
1995-12-31
On the two-loop Yukawa corrections to the MSSM Higgs boson masses at large tan(beta)
We complete the effective potential calculation of the two-loop, top/bottom Yukawa corrections to the Higgs boson masses in the Minimal Supersymmetric Standard Model, by computing the O(at^2 + at*ab + ab^2) contributions for arbitrary values of the bottom Yukawa coupling. We also compute the corrections to the minimization conditions of the effective potential at the same perturbative order. Our results extend the existing O(at^2) calculation, and are relevant in regions of the parameter space corresponding to tan(beta) >> 1. We extend to the Yukawa corrections a convenient renormalization scheme, previously proposed for the O(ab*as) corrections, that avoids unphysically large threshold effects associated with the bottom mass and absorbs the bulk of the corrections into the one-loop expression. For large values of tan(beta), the new contributions can account for a variation of several GeV in the lightest Higgs boson mass.
2003-01-01
Legislation scrubs fluegas emissions
Energy Technology Data Exchange (ETDEWEB)
The article profiles developments in pollution control resulting from the strict emissions control standards due to be set by the European Commission in 1992. In particular technology to meet new emissions targets for mercury and dioxins is described. Control technologies covered included fixed-bed, direct injection, circulating fluidized bed and spray adsorption all of which use activated charcoal to absorb dioxin and mercury. Unfortunately activated charcoal processes still leave waste to be disposed of. Options include recycling the spent activated charcoal to the incinerator, vitrifying the activated charcoal and fly ash into a glassy unleachable substance and cracking the dioxins catalytically. It is hoped the developments will increase public acceptance of incineration. 4 figs., 1 tabs.
1992-06-01
International Nuclear Information System (INIS)
The advent of multislice spiral CT (MSCT) technique has led to new aspects of dose reduction, especially for the dedicated use of MSCT in children. Optimizing pediatric MSCT protocols according to the clinical problem allows reduction of radiation exposure to a minimum without loss of diagnostic quality. The different parameters that influence the degree of dose reduction, like tube current-time product (mAs), tube voltage (kV), collimation and pitch, are discussed in context with previously published data and our own experience in nearly 200 pediatric CT examinations. In our department, the effective mAs is calculated for a pediatric chest MSCT by multiplication of the body weight in kilogram with a factor of 1 to 1.5 and for a pediatric abdominal MSCT by multiplication with a factor of 2 to 2.5. To calculate the equivalent effective dose for a contrast media-enhanced 80 kV protocol, the effective mAs of the 120 kV ...
2004-07-01
Concepts in radiation protection
International Nuclear Information System (INIS)
This monograph provides basic notions and principles in dosimetry and radiation protection in compliance with two fundamental works: IAEA Safety Series No.115 - International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources - and Publication no. 60 of International Commission on Radiological Protection. After the review of quantities and units necessary in radiation protection, the book presents the new values of dose limits as well as the values of 'radiation weighting factor', 'tissue weighting factor' and 'conversion factor intake-dose' (committed effective dose per unit intake) by ingestion and inhalation for 30 most important radionuclides. The new values of dose limits, lower than the old values, are a challenge for the radiation protection, especially of the 'public' where the dose limit diminished ...
1996-01-01
Energy Technology Data Exchange (ETDEWEB)
Radiation protection programs for workers are based, in the United States, on a hierarchy of limitations stemming from Federal guidance approved by the President. This guidance, which consists of principles, policies, and numerical primary guides, is used by Federal agencies as the basis for developing and implementing their own regulatory standards. The primary guides are usually expressed in terms of limiting doses to workers. The protection of workers against taking radioactive materials into the body, however, is accomplished largely through the use of regulations based on derived guides expressed in terms of quantities or concentrations of radionuclides. The values of these derived guides are chosen so as to assure that workers in work environments that conform to them are unlikely to receive radiation doses that exceed the primary guides. The purpose of the present report is to set forth derived guides that are ...
1988-09-01
Effect of radiation dose on the properties of natural rubber nanocomposite
Energy Technology Data Exchange (ETDEWEB)
Effect of radiation dose and carbon nanotubes (CNT) on the mechanical properties of standard Malaysian rubber (SMR) was investigated in this study. SMR nanocomposites containing 1-7 phr CNT were prepared using the solvent casting method and the nanocomposites were radiated at doses of 50-200 kGy. The change in mechanical properties, especially, tensile strength (Ts), elongation at break (Eb), hardness and tensile modulus at 100% elongation (M{sub 100}) were studied as a function of radiation dose. The structure and morphology of reinforced natural rubber was investigated by FESEM, TEM and AFM in order to gain further evidence on the radiation-induced crosslinking. It was found that the Ts, M{sub 100} and the hardness of the SMR/CNT nanocomposites significantly increased with radiation dose; the elongation at break exhibited an increase up to 100 kGy, and a downward trend thereafter. ...
2010-12-15
Dose assessment and behavior of tritium in environmental samples around Wolsong nuclear power plant.
For the estimation of the dispersion trend of tritium discharged from the Wolsung nuclear power plant, the present level of tritium in environmental samples in the vicinity of the Wolsong site has been studied. On the basis of tritium concentrations in environmental samples, the effective dose due to tritium has been estimated for an individual and population within a 16 km radius from the Wolsong site. The annual effective dose of tritium to an inhabitant around the Wolsong site ranged from 0.15 microSv y-1 to 1.3 microSv y-1. The dose level was negligible and much lower than some applicable standards, i.e. the limit on exposure from nuclear fuel cycle to the general public as recommended by ICRP (1 mSv y-1) or US EPA's limit (0.25 mSv y-1). The collective dose to the total population within a 16 km radius from the site, 1.2 x 10(-2) man.Sv y-1 was much lower than 1 man.Sv y-1, an ...
1999-04-01
Application of low-dose radiation protocols in survey CT scans
International Nuclear Information System (INIS)
Objective: To characterize the protocols with low-dose radiation in survey CT scans for localization. Methods: Eighty standard adult patients, head and body phantoms were recruited. Default protocols provided by operator's manual setting were that all the tube voltage for head, chest, abdomen and lumbar was 120 kV; the tube currents were 20,10,20 and 40 mA, respectively. Values of kV and mA in the low-dose experiments were optimized according to the device options. For chest and abdomen, the tube position were compared between default (0 degree) and 180 degree. Phantoms were scanned with above protocols, and the radiation doses were measured respectively. Paired t-test were used for comparisons of standard deviation in CT value, noise and exposure surface dose (ESD) between group with default protocols and group with optimized protocols. Results: The optimized ...
2009-08-01
Energy Technology Data Exchange (ETDEWEB)
A working group (SC 45B/WG B8) exists within the international electrochemical commission (IEC) which is working on the combination and revision of the IEC standards 61283, 61323, 61344, 61525 and 61526. All these standards concern direct reading, electronic, personal dose equivalent meters for the quantities H{sub p}(10) and H{sub p}(0,07); they are different with regard to the kind of radiation (photons, and/or beta rays and/or neutrons). The new standard with the number 61526 shall cover the following topics: 1. Combination of all the mentioned standards; 2. Maintenance of the essential requirements of the former standards; 3. Inclusion of the determination of the uncertainty of measurement for the measured dose equivalent value according to the ''Guide to the Expression of Uncertainty in Measurement''; ...
2001-07-01
Energy Technology Data Exchange (ETDEWEB)
In the latter half of 2005, the U.S. Environmental Protection Agency (USEPA) published a Proposed Rule (40 CFR Part 197) for establishing a dose rate standard for limiting radionuclide releases from the proposed Yucca Mountain high-level radioactive waste repository during the time period from 10{sup 4} to 10{sup 6} years after closure. The proposed standard was based on the difference in the estimated total dose rate from natural background in the Amargosa Valley and the ''average annual background radiation'' for the State of Colorado. As defined by the USEPA, ''natural background radiation consists of external exposures from cosmic and terrestrial sources, and internal exposures from indoor exposures to naturally-occurring radon''. On the basis of its assessments, the USEPA estimated that the difference in the ...
2006-02-24
Energy Technology Data Exchange (ETDEWEB)
In the case of total skin electron therapy without the beam guide, the electron beam is scattered just outside the gantry exit, dose uniformity in the field is broken, and dose is spread outside the light field. The aims of this study were to measure the mean energy of the off-axis incident electron beam without the beam guide and to establish a reference for the clinical situation. For the measurement, a 4 MeV electron beam was selected among several energies from the linear accelerator. A scintillating fiber beam energy monitor measured the mean energy of the incident electron beam. This energy monitor is a small, light-weight piece of equipment composed of a wedge absorber, scintillation fiber, and photodiode. We found the relationship between electron energy and the indicated value of the energy monitor by means of the estimation of correction factors for five different kinds of electron energy. The preferable linear ...
2002-06-01
International Nuclear Information System (INIS)
Processing of food with ionizing radiation is a method suitable to enhance shelf-life and hygienic quality. Up to a dose of 10 kGy the method is considered wholesome. In many countries the practical use of food irradiation is increasing, however, in the Federal Republic of Germany the process is strictly forbidden. Applications and methods for radiation processing of food are compiled, limits and prospects are explained, and advantages and disadvantages are compared with traditional methods. Identification of irradiated foods and dosimetry and process control for radiation processing of food are areas where further research is needed. Continuous processing of particulate foods in bulk is an application where electron accelerators might be profitable. Beam parameters and velocity distribution of food particles in the treatment area can be matched for an effective result. Thus, dose distribution can be adjusted for homogeneous treatment and at ...
Energy Technology Data Exchange (ETDEWEB)
The effect of a complexon therapy scheme including early (in 1 h) administration of Na/sub 3/Ca DTPA and subsequent administration of Na/sub 3/Zn DTPA or Na/sub 3/Ca DTPA at a dose of 25 ..mu..Cimol/kg/day by three 2-week courses (5 times a week) with 2-week interruptions was studied in experiments on 541 male rats after intraperitoneal administration of /sup 239/Pu citrate complex (95 kBq/kg). The treatment resulted in a 3-fold lessening of the content of /sup 239/Pu and absorbed doses in the skeleton, a significant prolongation of the mean survival time (MST) from 452 to 593 days (Na/sub 3/Zn DTPA) and 643 days (Na/sub 3/Ca DTPA), and in a decrease of the osteosarcoma incidence from 76.4 to 32.6-41.2%. The ratio of osteosarcomas per 1 Gy retained in rats (0.076-0.083 %) did not differ from that in untreated animals.
1985-02-01
Serum and salivary responses to oral tetravalent reassortant rotavirus vaccine in newborns.
UK PubMed Central (United Kingdom)
Serum and salivary responses of 95 infants to either a standard (4 x 10(4) plaque-forming units (PFU), 47 neonates) or a high dose (4 x 10(5) PFU, 48 neonates) of tetravalent reassortant rhesus rotavirus...Full Text Available
1993-05-01
Tumour control probability (TCP) for non-uniform activity distribution in radionuclide therapy
Energy Technology Data Exchange (ETDEWEB)
Non-uniform radionuclide distribution in tumours will lead to a non-uniform absorbed dose. The aim of this study was to investigate how tumour control probability (TCP) depends on the radionuclide distribution in the tumour, both macroscopically and at the subcellular level. The absorbed dose in the cell nuclei of tumours was calculated for {sup 90}Y, {sup 177}Lu, {sup 103m}Rh and {sup 211}At. The radionuclides were uniformly distributed within the subcellular compartment and they were uniformly, normally or log-normally distributed among the cells in the tumour. When all cells contain the same amount of activity, the cumulated activities required for TCP = 0.99 (A-tilde{sub TCP=0.99}) were 1.5-2 and 2-3 times higher when the activity was distributed on the cell membrane compared to in the cell nucleus for {sup 103m}Rh and {sup 211}At, respectively. TCP for {sup 90}Y was not affected by different ...
2008-08-21
Cytogenetic effects of protracted gamma exposures from conception of male mice
Energy Technology Data Exchange (ETDEWEB)
In order to gain an overall picture of the genetic effects of an increased level of background radiation it is necessary to study the results of protracted exposures to embryonic and immature germ-cell stages as well as to stages found in the mature organism. For this purpose, litters produced by female mice, kept in a 10 or 20 rad/day /sup 60/Co ..gamma..-irradiation field, were kept in the same fields from conception until about 60 days later, having absorbed doses of 526 and 1078 rad respectively. Tests on exposed female offspring showed them to be sterile. Eight weeks after removal from the gamma field, mean testis masses of males in the 20 rad/day series were only half normal but those receiving 10 rad/day were little affected. Frequencies of translocations in spermatocytes at diakinesis/metaphase I were only slightly increased in the exposed series, differences not being significant. Estimated rates of translocation induction were around ...
1982-01-01
Radionuclide air emissions report for the Hanford Site -- calendar year 1997
Energy Technology Data Exchange (ETDEWEB)
This report documents radionuclide air emission from the Hanford Site in 1997, and the resulting effective dose equivalent to the maximally exposed member of the public, referred to as the MEI. The report has been prepared in accordance with reporting requirements in the Code of Federal Regulations, Title 40, Protection of the Environment, Part 61, National Emissions Standards for Hazardous Air Pollutants, Subpart H, National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities. This report has also been prepared in accordance with the reporting requirements of the Washington Administrative Code Chapter 246-247, Radiation Protection-Air Emissions. The effective dose equivalent to the MEI from the Hanford Site`s 1997 point source emissions was 1.2 E-03 mrem (1.2 E-05 mSv), which is well below the 40 CFR 61 Subpart H regulatory limit of 10 mrem/yr. Radon ...
1998-06-17
Energy Technology Data Exchange (ETDEWEB)
CT-Expo is a novel MS Excel application for assessing the radiation doses delivered to patients undergoing CT examinations, based on computational methods that were used to analyze the data collected in the German survey on CT practice in 1999. The program enables the calculation of all dose quantities of practical value, such as axial dose free-in-air, weighted CTDI, dose-length product, effective dose and uterine dose. In contrast to existing programs for CT dose assessment, CT-Expo offers a number of unique features, such as gender-specific dose calculation for all age groups (adults, children, newborns), applicability to all existing scanner models including correction of scanner-specific influences, and the possibility of comparison with the results from the German CT survey on CT practice. Three different ...
2002-12-01
Deterministic calculations of radiation doses from brachytherapy seeds
International Nuclear Information System (INIS)
Brachytherapy is used for treating certain types of cancer by inserting radioactive sources into tumours. CDTN/CNEN is developing brachytherapy seeds to be used mainly in prostate cancer treatment. Dose calculations play a very significant role in the characterization of the developed seeds. The current state-of-the-art of computation dosimetry relies on Monte Carlo methods using, for instance, MCNP codes. However, deterministic calculations have some advantages, as, for example, short computer time to find solutions. This paper presents a software developed to calculate doses in a two-dimensional space surrounding the seed, using a deterministic algorithm. The analysed seeds consist of capsules similar to IMC6711 (OncoSeed), that are commercially available. The exposure rates and absorbed doses are computed using the Sievert integral and the Meisberger third order polynomial, respectively. The software ...
2003-08-17
Analyses of superficial and depth doses in intraoral radiology
Energy Technology Data Exchange (ETDEWEB)
In this work dosimetric analysis using thermoluminescence technique to study the beams characteristics of x-rays employed in dental radiology has been carried out. The obtained results with CaSO{sub 4}:Dy thermoluminescent dosimeters (TLD) were compared to the doses obtained with parallel-plates ionization chamber. Dosimetric evaluations were also done using radiographic films of large dimensions. The x-rays equipments analyzed were installed in the radiological services of Odontology Department of Sergipe Federal University (U.F.S.). Depending on the anatomical region to be examined the proper exposure time was select, for a fix voltage of 70 kV. The results with TLD and ionization chamber have been determined to female and male individuals. The intraoral regions analysed were the peri apical of the incisors, molar and pre-molar teeth and the occlusive region. These regions were simulated using acrylic plates absorbers installed on the film ...
2006-07-01
Salmonella radicidation of poultry carcasses
International Nuclear Information System (INIS)
This thesis reports investigations using gamma-radiation to decontaminate poultry carcasses. The application to foods of doses of ionizing radiation sufficient to reduce the number of viable specific non-sporeforming pathogenic microorganisms so that none is detectable in the treated food by any standard method is termed radicidation. The doses used in this study were at such a level that no undesirable or unfavourable side-effects occurred. The effects of these doses were studied on salmonellae and other microorganisms present in, or associated with poultry carcasses and in liquid and on solid culture media as well. Decimal reduction (D_1_0) values were estimated. These represent the dose (kGy) required to achieve a reduction in initial colony count from N_0 to 0.1 N_0. Together with the estimation of the numbers of Salmonella present per carcass the data were used to predict the ...
2005-09-22
Improvement of banana through biotechnology and mutation breeding
International Nuclear Information System (INIS)
Protocols were standardized for in vitro propagation of several elite and diverse banana accessions using shoot tip explants. Tissue culture raised plants were field planted at multiple locations. Studies were undertaken for the induction of mutations using multiple shoot cultures of six selected cultivars, Shreemanti (AAA), Basrai (AAA), Lal Kela (AAA), Rasthali (AAB), Karibale Monthan (ABB) and a wild diploid (BB). These shoot cultures were irradiated at different doses of gamma rays (0-100 Gy) and subcultured thrice (up to M_1V_3) to separate shimeras, followed by induction of rooting (M_1V_4). In general, the rate of multiplication had a negative association with the dose of gamma rays. Enhanced multiplication of shoots was noticed at lower doses. The proliferation of shoots was arrested beyond 50 Gy and a dose of 70 Gy was completely lethal for all the genotypes studied. The ...
1998-10-01
Elimination of organics chemicals in aqueous solutions by gamma radiation processing
International Nuclear Information System (INIS)
The objective this work was to evaluate the gamma radiation processing for elimination of organic contaminants on industrial wastewater. Standard samples with 17 hydrocarbons (acetophenone, anisole, benzene, chlorobenzene, cyclohexanone, N, N-dimethylaniline, phenol, naphtalene, 1-chloronaphtalene, n-octadecane, p-nitrotoluene, toluene, tetrachloroethane, tetramethylbenzene, n-undecane, m-xylene and o-xylene) was preparated in hexane with total concentration of 1 #mu# g/ #mu# l which was analyzed by gas chromatography. Other sample with the same concentration of these hydrocarbons in acetone was used to contaminate water samples, which were irradiated with gamma radiation from Co-60 between doses 5.0 to 20.0 KGy and dose rate of 1.162 KGy/h. The activity of source was 1470 Ci. Percents destruction of hydrocarbons were: 79.76 % to 5.0 KGy, 85.97 % to 7.5 KGy, 86.24 % to 10.0 KGy, 86.72 % to 12.5 KGy, 88.92 % to 15.0 KGy, ...
1992-08-16
Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart
Energy Technology Data Exchange (ETDEWEB)
The standard protocol in multislice spiral CT (MSCT) angiography for coronary arteries with fixed tube current-time settings leads to an overexposure and thus to an unnecessary high radiation dose in patients with lower weight when compared to heavier patients. The purpose of this study was to estimate the effect of reducing the radiation dose by adapting the tube current-time settings individually. Fifty patients underwent retrospectively ECG-gated MSCT of the heart. In 25 patients (group A{sub 1}) a standard protocol with constant tube current-time settings was used (4 x 1-mm collimation, 120 kV, 400 mAs{sub eff}). Subsequently, artificial image noise was added to the data of these patients simulating a directive for weight-adapted tube current-time settings (group A{sub 2}). In the other 25 patients (group B) an alternative protocol with individually weight-adapted tube current-time settings was ...
2003-12-01
Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart
International Nuclear Information System (INIS)
The standard protocol in multislice spiral CT (MSCT) angiography for coronary arteries with fixed tube current-time settings leads to an overexposure and thus to an unnecessary high radiation dose in patients with lower weight when compared to heavier patients. The purpose of this study was to estimate the effect of reducing the radiation dose by adapting the tube current-time settings individually. Fifty patients underwent retrospectively ECG-gated MSCT of the heart. In 25 patients (group A_1) a standard protocol with constant tube current-time settings was used (4 x 1-mm collimation, 120 kV, 400 mAs_e_f_f). Subsequently, artificial image noise was added to the data of these patients simulating a directive for weight-adapted tube current-time settings (group A_2). In the other 25 patients (group B) an alternative protocol with individually weight-adapted tube current-time settings was applied. The data ...
2003-12-01
Energy Technology Data Exchange (ETDEWEB)
Our objective was to evaluate the feasibility of ultra-low-dose scanning for multislice CT colonography in the detection of colorectal lesions. Twenty-seven patients (14 men, 13 women) with clinical indication for conventional colonoscopy were recruited. Multislice spiral CT (Somatom Plus 4 Volume Zoom, Siemens, Germany) examinations were performed after standard oral colonoscopic preparation and colonic distension with room air. Images were acquired using 2.5-mm collimation, 3.0-mm slice thickness, standard reconstruction kernel, 140 kVp, and 10 mAs. Supine and prone acquisitions were obtained in all patients. Images were analyzed on a workstation by two gastrointestinal radiologists. Conventional colonoscopy was performed on the same day in all patients and represented the standard of reference. Total radiation exposure was also calculated. All colorectal cancers were correctly identified at CT ...
2003-06-01
The effect of patient shield position on gonad dose during lumbar spine radiography
Energy Technology Data Exchange (ETDEWEB)
Background: In an effort to standardise radiological practices in the Republic of Ireland, current legislation states that 'written protocols for every type of standard radiological practice shall be established'. In order to fulfil this requirement the Irish Medical Council recommends the protocols issued by the Commission of European Communitees (CEC) for adoption in the country. Whilst this document does provide good guidance with regard to various radiographic factors, patient shielding instructions are notably ambiguous. The aim of this study was to remove some of this ambiguity by defining the optimal method of positioning patient shielding in antero-posterior (AP) and lateral lumbar spine radiographic examinations. These projections were chosen on the basis of their area of coverage being in close to and in some cases including the reproductive organs. They also represent the highest source of collective population dose ...
2010-05-15
The effect of patient shield position on gonad dose during lumbar spine radiography
International Nuclear Information System (INIS)
Background: In an effort to standardise radiological practices in the Republic of Ireland, current legislation states that 'written protocols for every type of standard radiological practice shall be established'. In order to fulfil this requirement the Irish Medical Council recommends the protocols issued by the Commission of European Communitees (CEC) for adoption in the country. Whilst this document does provide good guidance with regard to various radiographic factors, patient shielding instructions are notably ambiguous. The aim of this study was to remove some of this ambiguity by defining the optimal method of positioning patient shielding in antero-posterior (AP) and lateral lumbar spine radiographic examinations. These projections were chosen on the basis of their area of coverage being in close to and in some cases including the reproductive organs. They also represent the highest source of collective population dose of any ...
2010-05-01
Monte Carlo simulation and dosimetric verification of radiotherapy beam modifiers
International Nuclear Information System (INIS)
Monte Carlo simulation of beam modifiers such as physical wedges and compensating filters has been performed with a rectilinear voxel geometry module. A modified version of the EGS4/DOSXYZ code has been developed for this purpose. The new implementations have been validated against the BEAM Monte Carlo code using its standard component modules (CMs) in several geometrical conditions. No significant disagreements were found within the statistical errors of 0.5% for photons and 2% for electrons. The clinical applicability and flexibility of the new version of the code has been assessed through an extensive verification versus dosimetric data. Both Varian multi-leaf collimator (MLC) wedges and standard wedges have been simulated and compared against experiments for 6 MV photon beams and different field sizes. Good agreement was found between calculated and measured depth doses and lateral dose profiles ...
2001-11-01
UK regulations for NORM [naturally occurring radioactive material
International Nuclear Information System (INIS)
The primary UK legislation relating to the use of radioactive materials are the Radioactive Substances Act 1993 (RSA, 1993) and the Ionising Radiations Regulations 1999 (IRR, 1999). These implement the European Union's Basic Safety Standards Directive (EUBSS) (EC, 1996). The Radioactive Substances Act 1993 (RSA93) regulates the accumulation, storage and disposal of radioactive waste, principally to control potential doses to members of the public. The Ionising Radiations Regulations 1999 (IRR, 1999) deal primarily with regulating the doses that people receive at work. Both of these pieces of legislation apply to the use of materials containing naturally occurring radionuclides. Historically UK regulations relating to radioactive materials have covered both artificial and natural radionuclides
2002-09-23
Studies on natural radioactivity of some egyptian building materials
International Nuclear Information System (INIS)
Using high-resolution y-rays spectrometry, the natural radioactivity of 14 samples of natural and o manufactured Egyptian building materials have been investigated. The samples were collected from local market and construction sites. From the measured gamma-ray spectra, specific activities were determined. The radium equivalent activity in each sample was estimated. Radiological evaluations of these materials indicate that all materials meet the external gamma-ray dose limitation. Calculation of concentration indices by assuming a Markkanen room model is constructed from these materials, to find the excess gamma-ray dose taken over that received from the outdoors. The Austrian Standard ONORM S 5200 is used in testing the building materials.
2004-02-24
Radiation hardening of smart electronics
International Nuclear Information System (INIS)
Microprocessor based ''smart'' pressure, level, and flow transmitters were tested to determine the radiation hardness of this class of electronic instrumentation for use in reactor building applications. Commercial grade Complementary Metal Oxide Semiconductor (CMOS) integrated circuits used in these transmitters were found to fail at total gamma dose levels between 2500 and 10,000 rad. This results in an unacceptably short lifetime in many reactor building radiation environments. Radiation hardened integrated circuits can, in general, provide satisfactory service life for normal reactor operations when not restricted to the extremely low power budget imposed by standard 4--20 mA two-wire instrument loops. The design of these circuits will require attention to vendor radiation hardness specifications, dose rates, process control with respect to radiation hardness factors, and non-volatile programmable memory technology. 3 ...
International Nuclear Information System (INIS)
In this project, measurement of x-ray radiation dose level during radiological examination in Jos university teaching hospital and Plateau State specialist hospital at different locations within the department were carried out using radiation survey meter. The results were converted from micro sievert per hour (#mu#Sv/hr) to milisievert per year (mSv/yr). The radiation levels from the two hospitals visited ranged from 1.3m Sv/yr to 8.4m Sv/yr. This implies that all the radiology departments visited are still operating within the safety limit having less than 20 mSv/yr which is the standard permissible radiation level recommended per year.
2008-10-15
Effect of ionizing radiation on the properties of PLA packaging materials
International Nuclear Information System (INIS)
Poly(lactic acid) (PLA) is attractive as a substitute for classical polymer packaging material due to its biodegradability and sufficient mechanical and barrier properties. Presented research was focused on the changes of basic mechanical parameters after ionizing irradiation performed with doses in the range of 2.5-25 kGy, commonly used in radiation sterilization and preservation of foods. Two commercial available PLA packaging films were tested. The influence of radiation dose on the mechanical properties - tensile strength and elongation were determined using standardized methods. Radiation resistance of PLA is sufficient for packaging applications. The investigations of gas products of radiolysis of PLA have been made by gas chromatography after electron beam (EB) irradiations. (authors)
Development of calibration facility for radiation protection monitoring instruments
International Nuclear Information System (INIS)
Exposure control at the operating Nuclear Power Station is a major concern. The challenging task of meeting the International standards in the field of radiation protection is the calibration of the radiation monitoring instruments and interpretation of personnel and area monitoring results. Correct interpretation is based on accurate calibration of radiation measuring instruments. The reliability and accuracy of the measurements are also partly based on the procedures applied in calibration. Inadequate calibration can cause large errors in dose estimation in complete dose rate range and energy range. Semiautomatic calibration facility established at TAPS 3 and 4 for radiation monitoring instruments. Objective of calibration facility is (a) Ensure instruments are working properly (b) calibration adjustment and (c) in case without calibration adjustment to reveal the error involved. The calibration facility and calibration ...
2008-11-19
Regulations on health/functional foods in Korea
International Nuclear Information System (INIS)
The term 'health/functional food' (HFF) refers to food supplements containing nutrients or other substances (in a concentrated form) that have a nutritional or physiological effect whose purpose is to supplement the normal diet. The Korean Health/Functional Food Act that came into effect in 2004 requires these products to be marketed in measured doses, such as in pills, tablets, capsules, and liquids. HFFs are of two types: generic and product-specific. There are 37 ingredients listed in the act for generic HFFs, and if an HFF contains a new active ingredient that is not included in the generic 37 products, it is considered a product-specific HFF. The standardization, safety, and efficacy of a new active ingredient are reviewed by the Korean Food and Drug Administration in order to receive approval as a product-specific HFF. Conforming with international standards and protecting public health requires constant upgrading of ...
2006-04-03
Energy Technology Data Exchange (ETDEWEB)
The technical complexity of intraoperative radiotherapy (IORT) requires modification of the standard physical and dosimetric methods used in external electron beam therapy. At the National Cancer Institute, a number of technical innovations have been integrated into ongoing clinical studies of IORT. These include: (1) an electron beam applicator system that is significantly different from other IORT systems and includes customized squircle applicators; (2) peripheral dose shields; (3) a modified surgical table replacing the standard radiation treatment couch; and (4) routine use of multiple IORT fields that necessitates field matching. The IORT applicator system and related devices and techniques are dosimetrically characterized in detail both for use in the IORT program and in order to illustrate many useful facets of electron dosimetry.
1985-07-01
International Nuclear Information System (INIS)
Full text: A semiempirical algorithm for absorbed dose calculation at off-axis points in irregular beams was implemented. It is well known that semiempirical methods are very useful because of their easy implementation and its helpfulness in dose calculation in the clinic. These methods can be used as independent tools for dosimetric calculation in many applications of quality assurance. However, the applicability of such methods has some limitations, even in homogeneous media, specially at off axis points, near beam fringes or outside the beam. Only methods derived from tissue-air-ratio (TAR) or scatter-maximum-ratio (SMR) have been devised for those situations, many years ago. Despite there have been improvements for these manual methods, like the Sc-Sp ones, no attempt has been made to extend their usage at off axis points. In this work, a semiempirical formalism was introduced, based on the works of Venselaar et al. ...
2008-10-19
Performance testing of selected types of electronic personal dosimeters used in Sudan
International Nuclear Information System (INIS)
Measurements were carried out for calibration and performance testing of a set of 10 electronic personal dosimeters (EPDs) at the Secondary Standard Dosimetry Laboratory of Sudan. Calibrations were carried out at three X-ray beam qualities described in ISO standard 4037 in addition to 137Cs and 60Co gamma ray beams. The experimental was performed with EPDs mounted on ICRU Slab phantom. X-ray and ?-ray beams were characterized in terms of air kerma free-in-air which were converted to the known delivered personal dose equivalent, Hp(10) using appropriate the air kerma to personal dose equivalent conversion coefficients. Dosimeters tested showed excellent energy and angular response and relative error of indication within the recommended limit for photon energies from 65 keV to 1.25 MeV. The study showed encouraging results for using electronic dosimeters in personal dosimetry.
2010-12-01
Energy Technology Data Exchange (ETDEWEB)
The principle of radiodiagnosis consists in the fact the X-ray beam is attenuated at different degrees by distinct tissues. For this reason, the anatomical structures have distinct radiological opacities, that produce the radiographic image. The progresses in radiology are related to the development if new radiographic image formation systems that enable an amplification in the quality, with low dose and/or risk to the patient. The objective of this work is the sensitometric valuation of a screen-film combination, that is still the most used, for the standardization, of radiographic images. Thinking about this, were constructed homogeneous phantoms of the chest, skull and pelvis, for the calibration of X-ray beams, with the purpose of obtaining radiographic images of good quality, basing in the routine of a radiodiagnosis service and in the scientific knowledge. Questions were approached about the choice of the suitable equipment, that allow ...
1996-12-31
BDTPS The BNCT Treatment Planning System jointly developed at DIMNP and JRC/IE
The idea to couple the Treatment Planning System (TPS) to the information on the real boron distribution in the patient is the main added value of the new methodology set-up at DIMNP of University of Pisa, in collaboration with the JRC of Petten (NL). The methodology has been implemented in the new TPS, called BDTPS (Boron Distribution Treatment Planning System), which takes into account the actual boron distribution in the patient brain, while the standard TPS assumes a uniform boron distribution, absolutely far from the reality. Nowadays, Positron Emission Tomography (PET) is able to provide this in vivo information. The new TPS, based on the Monte Carlo technique, has been validated comparing the main BNCT parameters (thermal flux, boron dose, etc.) as measured during the irradiation of a special heterogeneous boron phantom (HEBOM), ad hoc designed, as calculated by the BDTPS and by the standard TPS SERA. An evident SERA ...
2003-01-01
Synthesis and PET imaging of the benzodiazepine receptor tracer [N-methyl-"1"1C]iomazenil
International Nuclear Information System (INIS)
The central benzodiazepine receptor tracer [N-methyl-"1"1C]iomazenil (Ro 16-0154) was synthesized by alkylation of the desmethyl precursor noriomazenil with ["1"1C]methyl iodide. The ["1"1C]CH_3I (prepared by reduction of ["1"1C]CO_2 with LiAlH_4 followed by reaction with HI) was reacted with noriomazenil inN,N -dimethylformamide and Bu_4N"+OH"- for 1 min at 80 deg. C and purified by HPLC (C_1_8, 34% CH_3CN/H_2O, 7 mL/min). The product was obtained with synthesis time 35 #+-# 5 min (mean #+-# SD, n = 7), radiochemical yield (EOB) 36 #+-# 16%, radiochemical purity 99 #+-# 1%, and specific activity 5100 #+-# 2800 mCi/#mu#mol. Absorbed radiation doses were calculated from previously acquired human biodistribution data. The urinary bladder wall received the highest dose (0.099 mGy/MBq) for 4.8 h voiding interval and the effective dose equivalent was 0.015 mSv/MBq. After i.v. injection of ["1"1C]iomazenil in ...
1995-07-01
Energy Technology Data Exchange (ETDEWEB)
Molybdenum is an essential element for living organisms. Moreover its radionuclides may represent an incorporation risk for members of the public and/or radiation workers after a nuclear accident or a release of radioactive materials. However, only few reliable data on Mo biokinetics in humans were available. The results of recent tracer kinetic investigations with stable isotopes have shown several differences from the ICRP data with regard to the processes of intestinal absorption and of excretion. As a consequence, the dose coefficients calculated with a revised biokinetic model deviate from the ICRP estimates. By ingestion of {sup 99}Mo radionuclides with solid food, for example, the dose to the colon may be higher of a factor up to 1 order of magnitude, due to the fraction of non-absorbed material which traverses the gastro-intestinal tract. (orig.) [Deutsch] Molybdaen ist einerseits ein fuer Lebewesen essentielles ...
1998-12-31
Energy Technology Data Exchange (ETDEWEB)
The distribution of carrier free lead-203 between plasma and cells of canine blood in vitro was measured. Activity in the plasma decreased to less than 5% of the initial blood activity during the first 15 min and then exponentially with a half time of 160 min. Incubation in cell free plasma before addition to whole blood transformed the isotope, decreasing the amount subsequently associated with cells. In animal studies, activity was measured in plasma, blood cells, urine, and feces after exposure to lead-203. In one group, the animals were exposed by intravenous injection of dilute citric acid solutions of isotope. In a second group, carrier free isotope which had been transformed by incubation in plasma was injected intravenously. The kinetics of the distribution of the isotope differed between the two experimental groups. After injection of the transformed lead, the lead-203 content of the blood cell fraction rose from 10% of the dose at 5 min to 21% to 43% at ...
1980-01-01
Energy Technology Data Exchange (ETDEWEB)
Hepatocellular carcinoma (HCC) is the most common primary liver cancer and has very limited therapeutic options. Recently, it has been found that hyaluronic acid (HA) shows selective binding to CD44 receptors expressed in most cancer histotypes. Since the trend in cancer treatment is the use of targeted radionuclide therapy, the aim of this research was to label HA with rhenium-188 and to evaluate its potential use as a hepatocarcinoma therapeutic radiopharmaceutical. Methods: {sup 188}Re-HA was prepared by a direct labelling method to produce a ReO(O-COO){sub 2}-type coordination complex. {sup 188}Re-HA protein binding and its stability in saline, phosphate buffer, human serum and cysteine solutions were determined. Biokinetic and dosimetric data were estimated in healthy mice (n=60) using the Medical Internal Radiation Dose methodology and mouse model beta-absorbed fractions. To evaluate liver toxicity, alanine aminotranferase (AST) and ...
2009-08-15
Antimicrobials in the Management of Post-Irradiation Infection
... develops. An alternative approach is the use of non-absorbable antibiot- ics such as polymyxin, neomycin, and bacitracin. ...
2011-05-13
Resuscitation and monitoring in gastrointestinal bleeding
British Library Electronic Table of Contents (United Kingdom)
Introduction Gastrointestinal bleeding is a common life-threatening problem, causing significant mortality, costs and resource allocation. Its management requires a dynamic multidisciplinary approach that directs diagnostic and therapeutic priorities appropriately. Materials and methods Articles published within the past 15 years, related to gastrointestinal bleeding, were reviewed through MEDLINE search, in addition to current guidelines and standards. Results Decisions of ICU admission and blood transfusion must be individualized based on the extent of bleeding, hemodynamic profile and comorbidities of the patient and the risk of rebleeding. A secure airway may be required to optimize oxygenation and to prevent aspiration. Doses of induction agents must be reduced due to the changes in v...
2011-01-01
International Nuclear Information System (INIS)
The Seismic Proving Test of Heavy Component with Energy Absorbing Supports has been conducted to prove the reliability of advanced seismic technology, supporting heavy component such as PWR steam generator with large capacity energy absorbing supports under the sponsorship of Ministry of Economical Trade and Industry. If energy absorbing supports are adopted for NPP heavy components, support structure of facility will be much simplified due to their seismic energy absorbing effect. The paper describes the results of lead damper element test and seismic test at Tadotsu Laboratory, using 1/2.5 scale PWR Steam Generator model supported by Lead Extraction Damper (LED) and development of characteristics evaluation formula of energy absorbing support. (author)
2003-09-15
Radiation-induced reduction of ditetrazolium salt in aqueous solutions
Energy Technology Data Exchange (ETDEWEB)
Color formation in aqueous solutions of the ditetrazolium salt blue tetrazolium (BT{sup 2+}) in the absence or presence of oxygen is a complex radiation chemical reaction. The final stable product is the poorly soluble diformazan violet to blue pigment having a broad spectral absorption band ({lambda}{sub max}=552 nm). The reaction of BT{sup 2+} with the hydrated electron proceeds by rapid reduction of BT{sup 2+} followed by protonation at the nitrogen closest to the unsubstituted phenyl group, via the two intermediate tetrazolinyl radicals shared by the ditetrazole ring nitrogens. The effect of solution pH, N{sub 2}O saturation, and the presence of the reducing agent dextrose are examined. The system serves as a radiochromic sensor and a dosimeter of ionizing radiations. Solutions of 5 mmol l{sup -1} BT{sup 2+} at pH 7.3 serve as dosimeters over an absorbed-dose range of approximately 0.2-6 kGy (dearated, with a range of 1-8 mmol l{sup -1} dextrose) and of about ...
2002-04-01
Energy Technology Data Exchange (ETDEWEB)
Natural radioactive materials under certain conditions can reach hazardous radiological levels. The natural radionuclide ({sup 238}U, {sup 232}Th, {sup 40}K) contents of rock samples at various locations in the North Tushki area were investigated using gamma-spectrometric analysis. Estimates of the measured radionuclide content have been made for the absorbed dose rate of gamma radiation. The equivalent radium (R{sub eq}) and the external hazard index (H{sub ex}) which resulted from the natural radionuclides in soil are also calculated and tabulated. The studied samples have been collected from various rock exposures in the North Tushki area. The distribution of major oxides, U and Th were studied. It is found that the enrichment and depletion of the major oxides are mainly due to the effect of hydrothermal alteration, which caused mobility of some major oxides, which increases some elements and decreases others. It is important to mention that ...
2002-09-01
Calibration of the Capintec CRC-712M dose calibrator for "1"8F
International Nuclear Information System (INIS)
Primary standardisation was performed on a solution of "1"8F using the 4#pi##beta#-#gamma# coincidence counting efficiency-tracing extrapolation method with "6"0Co used as a tracer nuclide. The result was used to calibrate the ANSTO secondary standard ionisation chamber which is used to disseminate Australian activity standards for gamma emitters. Using the secondary activity standard for "1"8F, the Capintec CRC-712M dose calibrator at the Australian National Medical Cyclotron (NMC) Positron Emission Tomography (PET) Quality Control (QC) Section was calibrated. The dial setting number recommended by the manufacturer for the measurement of the activity of "1"8F is 439. In this work, the dial setting numbers for the activity measurement of the solution of "1"8F in Wheaton vials were experimentally determined to be 443+/-12, 446+/-12, 459+/-11, 473+/-15 for 0.1, 1, 4.5 and 9ml solution volumes, ...
2006-04-01
Energy Technology Data Exchange (ETDEWEB)
The aim of this study is three folds: to compare the eight-channel phased-array and standard circularly polarized (CP) head coils in visualiazation of the intracranial vessels, to compare the three-dimentional (3D) time-of-flight (TOF) MR angiography (MRA) techniques, and to define the effects of parallel imaging in 3D TOF MRA. Fifteen healthy volunteers underwent 3D TOF MRA of the intracranial vessels using eight-channel phased-array and CP standard head coils. The following MRA techniques were obtained on each volunteer: (1) conventional 3D TOF MRA with magnetization transfer; (2) 3D TOF MRA with water excitation for background suppression; and (3) low-dose (0.5 ml) gadolinium-enhanced 3D TOF MRA with water excitation. Results are demonstrating that water excitation is a valuable background suppression technique, especially when applied with an eight-channel phased-array head coil. For central and proximal portions of the ...
2004-11-01
Development of a HVDC prototype breaker. Final report
Energy Technology Data Exchange (ETDEWEB)
The significant design features of a high-voltage dc (HVDC) circuit breaker based on the commutation concept were developed. Tests of components indicate the breaker is capable of interrupting a fault current of 10 kA on a 400 kV system and absorbing up to 10 MJ of system energy without generating more than 1.6 per unit (P.U.) voltage of the system. Interactions of the breaker with a three-terminal network were studied, using a system simulator. An ultrafast hydraulic actuator system was developed for this program which enables the breaker to initiate the current limiting process within 5 ms after receipt of a trip signal. A new hydraulic valve, operated by a repulsion coil, minimizes the delay before motion begins. Interruption will occur in series-connected vacuum interrupters. A 400 kV circuit breaker is estimated to require eight breaks in series. Only a single break was tested as part of this program because of the scale and cost required for multibreak tests. ...
1980-06-01
Control of population dose equivalent from naturally occurring radionuclides in building materials
International Nuclear Information System (INIS)
Naturally occurring radionuclides in building materials are a source of external and interal radiation exposure to essentially the entire US population. Although detailed data are not available, estimates are that the average contribution from such sources to the external dose equilvaent rate in brick and masonry houses is about 5 to 10 mrem/year. For critical population groups, values reported in the literature for the contribution from such sources range up to a hundred mrem/year or more. Dose equivalent rates to the lungs are even higher and, for abnormal situations, it would appear that control measures, either on a voluntary or mandatory (legislative) basis should be considered. Such measures include: (1) material substitution; (2) improved manufacturing standards; (3) changes in basic building designs; (4) application of surface sealants; and (5) increased ventilation accompanied by processes for the adsorption and/or ...
Computed radiography. Evaluation of its role in the mass survey for lung cancer: Phantom study
Energy Technology Data Exchange (ETDEWEB)
In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in the lung field and in the retrocardiac and subdiaphragmatic regions, respectively. This may have implications for the value of simultaneous ...
1987-12-01
International Nuclear Information System (INIS)
In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in the lung field and in the retrocardiac and subdiaphragmatic regions, respectively. This may have implications for the value of simultaneous ...
1987-01-01
The natural background approach to setting radiation standards
International Nuclear Information System (INIS)
The suggestion has often been made that an additional radiation exposure imposed on humanity as a result of some important activity such as electricity generation would be acceptable if the exposure was 'small' compared to the natural background. In order to make this concept quantitative and objective, we propose that 'small compared with the natural background' be interpreted as the standard deviation (weighted with the exposed population) of the natural background. We believe that this use of the variation in natural background radiation is less arbitrary and requires fewer unfounded assumptions than some current approaches to standard-setting. The standard deviation is an easily calculated statistic that is small compared with the mean value for natural exposures of populations. It is an objectively determined quantity and its significance is generally understood. Its determination does not omit any of the pertinent ...
1979-03-09
Production of hydrogen by radiolysis
Energy Technology Data Exchange (ETDEWEB)
The possibility of obtaining high yields of hydrogen through the exposure of calcium hydroxide to natural uranium fission fragments is confirmed experimentally. The amounts of hydrogen obtained in some experiments were determined not only from the mass-spectrometry data, but also with the use of standard chemical analysis methods. The radiolytic hydrogen yield averaged over six independent experiments comprises 20.41 hydrogen molecules per 100 eV of absorbed fission fragment energy. The corresponding energy efficiency makes up to 60.62. Since on interaction with water or water vapor calcium hydroxide enters into the exothermal reaction to liberate 15.6 kcal/mole, it can easily be regenerated; this was attested to by one of irradiation experiments. Therefore, in the long run, we are dealing with a radiolytic decomposition of water at low temperatures or at temperatures readily available with modern reactor engineering techniques. Comparison of ...
1998-07-01
Development of production methods of volume source by the resinous solution which has hardening
Volume sources is used for standard sources by radioactive measurement using Ge semiconductor detector of environmental sample, e.g. water, soil and etc. that require large volume. The commercial volume source used in measurement of the water sample is made of agar-agar, and that used in measurement of the soil sample is made of alumina powder. When the plastic receptacles of this two kinds of volume sources were damaged, the leakage contents cause contamination. Moreover, if hermetically sealing performance of volume source made of agar-agar fell, volume decrease due to an evaporation off moisture gives an error to radioactive measurement. Therefore, we developed the two type methods using unsaturated polyester resin, vinilester resin, their hardening agent and acrylicresin. The first type is due to dispersing the hydrochloric acid solution included the radioisotopes uniformly in each resin and hardening the resin. The second is due to dispersing the alumina ...
2002-01-01
Energy Technology Data Exchange (ETDEWEB)
Background: The difficulty of directly measuring cellular dose is a significant obstacle to application of target tissue dosimetry for nanoparticle and microparticle toxicity assessment. As a consequence, the target tissue paradigm for dosimetry and hazard assessment of nanoparticles has largely been ignored in favor of using metrics of exposure (e.g. ?g particle/mL culture medium, particle surface area/mL, particle number/mL). We have developed a computational model of solution particokinetics (sedimentation, diffusion) and dosimetry for non-interacting spherical particles and their agglomerates in monolayer cell culture systems. Particle transport to cells is calculated by simultaneous solution of Stokes Law (sedimentation) and the Stokes-Einstein equation (diffusion). Results: The In vitro Sedimentation, Diffusion and Dosimetry model (ISDD) was tested against measured transport rates or cellular doses for multiple sizes of polystyrene ...
2010-11-30
Physics and quality assurance of low dose rate brachytherapy
International Nuclear Information System (INIS)
Purpose: The purpose of this course is to review the physical principles underlying design, clinical application and execution of interstitial and intracavitary implants in the classical low dose-rate (LDR) range. This year, the course will focus on quality assurance of sources, applicators and treatment planning software. In addition, development of procedures and QA checks designed optimize treatment delivery accuracy and patient safety during each individual procedure will be reviewed. The level of presentation will be designed to accommodate both physicists and physicians. Implementation of recently published AAPM Task Group reports (no. 40, 'Comprehensive Quality Assurance' and No. 43, 'Dosimetry of Interstitial Brachytherapy Sources') will be reviewed. Outline: (A) General Principles (1) QA endpoints: temporal accuracy, positional accuracy, dose delivery accuracy, and safety of the patient, personnel, and the institution (2) QA procedure ...
International Nuclear Information System (INIS)
Purpose: This study presents a dosimetric optimization effort aiming to compare intensity-modulated (IM) X-rays and IM protons in 4 different orbital and paraorbital tumors. These are most challenging targets for standard radiotherapy due to their close relationship with the eyes and related structures. Methods and Materials: A primary orbital lymphoma, an optic nerve meningioma, a sphenoidal ridge meningioma protruding into the orbit, and a pediatric parameningeal paraorbital rhabdomyosarcoma were selected for the purpose of this study. Planning target volumes (PTVs) and organs at risk (OAR) were defined in each patient CT data set for each tumor site. IM X-ray and IM proton three-dimensional treatment plans were implemented. The following total tumor doses were prescribed: 30 Gy for the orbital lymphoma, 54 Gy for both meningiomas, and 50.4 Gy for the rhabdomyosarcoma case. Dose-volume histograms (DVHs) were obtained for ...
2000-07-01
The Development of 6061-Aluminum Windows for the MICE LiquidAbsorber
Energy Technology Data Exchange (ETDEWEB)
The thin windows for the Muon Ionization Cooling Experiment (MICE) liquid Absorber will be fabricated from 6061-T6-aluminum. The absorber and vacuum vessel thin windows are 300-mm in diameter and are 180 mm thick at the center. The windows are designed for an internal burst pressure of 0.68 MPa (100 psig) when warm. The MICE experiment design calls for changeable windows on the absorber, so a bolted window design was adopted. Welded windows offer some potential advantages over bolted windows when they are on the absorber itself. This report describes the bolted window and its seal. This report also describes an alternate window that is welded directly to the absorber body. The welded window design presented permits the weld to be ground off and re-welded. This report presents a thermal FEA analysis of the window seal-weld, while the window is being welded. Finally, the results of a ...
2005-08-24
Technology of iodine-131 production and its application
International Nuclear Information System (INIS)
Full text: Production: This radio iodine produced by three methods: 1) Wet method: The irradiated tellurium is dissolved in an oxidizing mixture which also converts iodine in to iodide. This is a chemical method and iodine that it produced with this method has low purity and efficiency. 2). Dry Method: The irradiated tellurium is dissolved in furnace (750 deg. C) with sublimation method and iodine absorbed in sodium solution . In this case we have more than 99.5 % purity and 80 % efficiency. We are using this type in Iran. 3) Fission fragment method: In this case the iodine separated from fission fragment directly and we have high purity (career free) and specific activity of iodine. Application: Iodine is a versatile tracer element. It is used to determine thyroid cancer metastases, and size, shape and activity of the thyroid gland. Critical organ of iodine is thyroid gland. One of the common diagnostic procedures for determining thyroid function therefore, is to ...
Radiation testing of organic ion exchange resins
International Nuclear Information System (INIS)
A number of ion exchange materials are being evaluated as part of the Tank Waste Remediation System (TWRS) Pacific Northwest Laboratory (PNL) Pretreatment Project for the removal of "1"3"7Cs from aqueous tank wastes. Two of these materials are organic resins; a phenol-formaldehyde resin (Duolite CS-100) produced by Rohm and Haas Co. (Philadelphia, Pennsylvania) and a resorcinol-formaldehyde (RF) resin produced by Boulder Scientific Co. (Mead, Colorado). One of the key parameters in the assessment of the organic based ion exchange materials is its useful lifetime in the radioactive and chemical environment that will be encountered during waste processing. The focus of the work presented in this report is the radiation stability of the CS-100 and the RF resins. The scope of the testing included one test with a sample of the CS-100 resin and testing of two batches of the RF resin (BSC-187 and BSC-210). Samples of the exchangers were irradiated with a "6"0Co source to a total ...
1983-04-11
Radiation testing of organic ion exchange resins
Energy Technology Data Exchange (ETDEWEB)
A number of ion exchange materials are being evaluated as part of the Tank Waste Remediation System (TWRS) Pacific Northwest Laboratory (PNL) Pretreatment Project for the removal of {sup 137}Cs from aqueous tank wastes. Two of these materials are organic resins; a phenol-formaldehyde resin (Duolite CS-100) produced by Rohm and Haas Co. (Philadelphia, Pennsylvania) and a resorcinol-formaldehyde (RF) resin produced by Boulder Scientific Co. (Mead, Colorado). One of the key parameters in the assessment of the organic based ion exchange materials is its useful lifetime in the radioactive and chemical environment that will be encountered during waste processing. The focus of the work presented in this report is the radiation stability of the CS-100 and the RF resins. The scope of the testing included one test with a sample of the CS-100 resin and testing of two batches of the RF resin (BSC-187 and BSC-210). Samples of the exchangers were irradiated with a {sup 60}Co source to a total ...
1995-09-01
Radiation dosimetry of "1"1"1In-oxinate labelled leucocytes
International Nuclear Information System (INIS)
The patients studied were referred for routine abscess localization with indium-111 labelled autologous leukocytes. One series (n=15) was studied at 1 day after reinjection of labelled cells and a second series (n=9) was studied between 4 hours and 4 days after reinjection of labelled cells. The leukocytes were isolated by a gravity sedimentation method and labelled with In-111 oxinate according to Roevekamp and co-workers. The labelled cell suspension administered to the patient contained between 11 and 15 MegaBq (300-400 microCi). The indium-111 concentration in the liver and spleen was quantitated using a scintillation camera and an on-line computer system. Phantom studies were carried out to obtain conversion factors from geometric mean counts to MegaBq of activity for both liver and spleen. Once determined, the amount of activity in liver and spleen was corrected for physical decay of In-111 and expressed as a percentage of the administered activity. Additionally in the 2nd series ...
1982-06-25
Prototype exposure chamber of radon for animal experiments
Energy Technology Data Exchange (ETDEWEB)
To evaluate a dose conversion factor from the `Working Level of Month` (WLM) of radon to the absorbed dose (mGy), the quality of radon and its progeny was assessed, and exposures controlled for each deposition region were planed as follows: 1) exposure of radon gas to the entire respiratory tract, 2) exposure of `unattached` fractions to the upper respiratory tract, 3) exposure of `attached` fractions onto ultrafine particles to the deep lung, 4) exposure of `attached` fractions onto fine particles to the lower respiratory tract, 5) exposure of `attached` fractions onto coarse particles to the upper respiratory tract. In this preliminary study, a prototype exposure system of radon and its progeny for small rodents was designed. A whole body exposure chamber with a volume of about 0.5 m{sup 3} was used, which it held 20 rats. The aging and mixing chamber separated by the exposure chamber had a volume of about 1 m{sup 3}. As ...
1998-12-31
Energy Technology Data Exchange (ETDEWEB)
The optically stimulated luminescence (OSL) results a highly appropriate dosimetric technique for readings of absorbed radiation 'in alive' and 'in situ', as well as in real time. The CVD diamond on the other hand presents excellent qualities like radiation reader thanks to its reproducibility, radiation resistance, biocompatibility and non toxicity. The present work studies the answer of two diamond films pure and polluted with nitrogen (750 ppm) grown by the Chemical Vapor Deposition method (CVD) on silicon substrate (001) irradiated with beta (Sr-90) in the 0.833-100 Gy interval. The optical stimulation was carried out by 40 seconds with infrared laser (830 nm, 0.36 W/cm{sup 2}) and the filter BG-39 (300-600 nm) coupled the PM. The intensity and the decay of the hyperbolic type of the LOE curves were similar in both samples, for the non doped diamond were observed trapping states in 200-380 C being compared with those that it ...
2006-07-01
Neurotoxicological effects of cinnabar (a Chinese mineral medicine, HgS) in mice
International Nuclear Information System (INIS)
Cinnabar, a naturally occurring mercuric sulfide (HgS), has long been used in combination with traditional Chinese medicine as a sedative for more than 2000 years. Up to date, its pharmacological and toxicological effects are still unclear, especially in clinical low-dose and long-term use. In this study, we attempted to elucidate the effects of cinnabar on the time course of changes in locomotor activities, pentobarbital-induced sleeping time, motor equilibrium performance and neurobiochemical activities in mice during 3- to 11-week administration at a clinical dose of 10 mg/kg/day. The results showed that cinnabar was significantly absorbed by gastrointestinal (G-I) tract and transported to brain tissues. The spontaneous locomotor activities of male mice but not female mice were preferentially suppressed. Moreover, frequencies of jump and stereotype-1 episodes were progressively decreased after 3-week oral administration ...
2007-10-15
Gastrointestinal absorption of lead (/sup 203/Pb) in chicks: influence of lead, calcium, and age
Energy Technology Data Exchange (ETDEWEB)
The present study was designed to investigate, in more detail, the mechanism of lead transport by the gastrointestinal tract and particularly the similarities or dissimilarities between lead and calcium in this process. The absorption of these metals was determined in 3-week-old white Leghorn cockerels, raised on a commercial diet or special diets, using an in vivo ligated loop procedure. The dose administered into the loop usually contained 0.5 ..mu..Ci /sup 203/Pb (and/or 0.1 ..mu..Ci /sup 47/Ca), 0.01 mM lead acetate (and/or 1 mM CaCl/sub 2/) in 0.5 ml of 0.15 M NaCl, pH 6.5. It was shown that lead is rapidly taken up by the intestinal tissue, and only slowly transferred into the circulation whereas calcium, also accumulated rapidly by the tissue, is rapidly released from the tissue in the serosal direction. The absorption processes of these cations show similar responses to various experimental conditions (low calcium intake, age of the animal, pH of the ...
1981-10-01
International Nuclear Information System (INIS)
Electron beams as a source of directed energy are under study at the Lawrence Livermore National Laboratory (LLNL). An intense 10-kA, 50-MeV, 50-ns full-width half-maximum, pulsed electron beam is generated by the prototype Advanced Test Accelerator (ATA) at the Laboratory's Site 300. Whenever the electron beam is stopped in materials, intense radiation is generated. Estimates based on available data in the literature show that for materials such as lead, photon radiation (x ray, gamma, bremsstrahlung) levels can be as large as 10"4 roentgens per pulse at 1 m in the zero-degree direction (i.e., the electron-beam direction). Neutrons, which are emitted isotropically, are produced at a level of 10"1"3 n/m"2 per pulse. Depending upon the number of pulses and the shielding geometry, the accumulated dose is potentially lethal to personnel and potentially damaging to instrumentation that may be used for diagnostics. To provide shielding for minimizing the risk of ...
Energy Technology Data Exchange (ETDEWEB)
The principal mathematical tools frequently available for calculations in Nuclear Engineering, including coupled neutron-gamma radiations shielding problems, involve the full Transport Theory or the Monte Carlo techniques. The Multigroup Albedo Method applied to shieldings is characterized by following the radiations through distinct layers of materials, allowing the determination of the neutron and gamma fractions reflected from, transmitted through and absorbed in the irradiated media when a neutronic stream hits the first layer of material, independently of flux calculations. Then, the method is a complementary tool of great didactic value due to its clarity and simplicity in solving neutron and/or gamma shielding problems. The outstanding results achieved in previous works motivated the elaboration and the development of this study that is presented in this dissertation. The radiation balance resulting from the incidence of a neutronic stream into a shielding ...
2002-07-01
Analysis of coupled neutron-gamma radiations, applied to shieldings in multigroup albedo method
International Nuclear Information System (INIS)
The principal mathematical tools frequently available for calculations in Nuclear Engineering, including coupled neutron-gamma radiations shielding problems, involve the full Transport Theory or the Monte Carlo techniques. The Multigroup Albedo Method applied to shieldings is characterized by following the radiations through distinct layers of materials, allowing the determination of the neutron and gamma fractions reflected from, transmitted through and absorbed in the irradiated media when a neutronic stream hits the first layer of material, independently of flux calculations. Then, the method is a complementary tool of great didactic value due to its clarity and simplicity in solving neutron and/or gamma shielding problems. The outstanding results achieved in previous works motivated the elaboration and the development of this study that is presented in this dissertation. The radiation balance resulting from the incidence of a neutronic stream into a shielding ...
2002-01-01
Energy Technology Data Exchange (ETDEWEB)
The radionuclide characteristics of light-water-reactor (LWR) spent fuel play key roles in the design and licensing activities for radioactive waste transportation systems, interim storage facilities, and the final repository site. Several areas of analysis require detailed information concerning the time-dependent behavior of radioactive nuclides including (1) neutron/gamma-ray sources for shielding studies, (2) fissile/absorber concentrations for criticality safety determinations, (3) residual decay heat predictions for thermal considerations, and (4) curie and/or radiological toxicity levels for materials assumed to be released into the ground/environment after long periods of time. The crucial nature of the radionuclide predictions over both short and long periods of time has resulted in an increased emphasis on thorough validation for radionuclide generation/depletion codes. Current radionuclide generation/depletion codes have the capability to follow the ...
1995-01-01
... energy absorption characteristics of composite sandwich panels, thermoplastic energy-absorbing subfloor structures, and shoulder belt pre- tensioners. ...
Kootenai River Nutrient Dosing System and N-P Consumption: Year 2008.
In early 2006 we designed and built low energy consumption, pump-operated system, for dosing of the liquid nutrient in the summer 2006 season. This operated successfully, and the system was used again during the 2007 and 2008 seasons for dosing. During the early winter period, 2008, laboratory tests were made of the liquid nutrient pump system, and it was noted that small amounts of air were being entrained on the suction side of the pump, during conditions when the inlet pressure was low. It was believed that this was the cause of diurnal fluctuations in the flow supplied, characteristic of the 2007 year flow data. Replacement of '0' rings on the inlet side of the pumps was the solution to this problem, and when tested in the field during the summer season, the flow supplied was found to be stable. A decision was made by the IKERT committee at the meeting of 20th to 21st May 2008 (held in Coeur d'Alene, Idaho) to use ...
2009-02-19
Random motion of a particle emitting and absorbing tachyons
International Nuclear Information System (INIS)
Random motion of a particle, emitting and absorbing tachyons, is investigated. It is shown that if bradyon is in equilibrium with neutral gas, i.e. it absorbs and emits tachyons, which do not have any charges, tha particle with each absorption-emittance of a tachyon changes its energy and momentum, never varying its own mass, and as a result it moves like a brownian particle. Thus, bradyon, interacting with tachyon gas, increases its momentum continuously in agreement with the Einstein-Fokker-Planck type equation.
Disposal of old heads for Daya Bay NPP
International Nuclear Information System (INIS)
The paper introduces the disposal procedures of the old reactor pressure vessel head. Reactor pressure vessel (RPV) heads were replaced successfully in Daya Bay Nuclear Power Plant. The on-site treatment and disposal of replaced heads was thereafter implemented. This is the first time in China for large size radioactive article disposal. To guarantee the safety of old head treatment, issues of radiation protection have to be taken into account. Dose rate distribution of the old head surface and radioactivity were initially calculated according to the operation history and the neutron flux rate of the reactor. Shielding calculation and package design was thereafter worked out based on the data obtained from the old head, e.g. neutron flux, sorts of nuclides, radioactivity and dose rates. Shielding package was afterwards manufactured in special factories and transported to Daya Bay NPP site by truck and ship. The shielding package was designed ...
Development of an irradiation system for a small size continuous run multipurpose gamma irradiator
International Nuclear Information System (INIS)
The Radiation Technology Center from IPEN-CNEN/SP, Brazil, developed a revolutionary design and national technology, a small-sized continuous run and multipurpose industrial gamma irradiator, to be used as a demonstration facility for manufacturers and contract service companies, which need economical and logistical in-house irradiation system alternatives. Also, to be useful for supporting the local scientific community on development of products and process using gamma radiation, assisting the traditional and potential users on process validation, training and qualification of operators and radioprotection officers. The developed technology for this facility consists of a continuous tote box transport system, comprising a single concrete vault, where the automated transport system of products inside and outside of the irradiator utilizes a rotating door, integrated with the shielding, avoiding the traditional maze configuration. Covering 76 m"2 of floor area, the irradiator design is ...
Production and Purification of UO_3 from rock phosphate deposits and its characterization
International Nuclear Information System (INIS)
This study was carried out mainly to produce uranium trioxide (UO_3), matching standard commercial specification from rock phosphate deposits in Uro and Kurun at eastern part of the Nuba Mountains. A simplified hydrometallurgical procedure has been adopted for production of yellow cake from the ore. The powdered ore sample was leached with concentrated H_2SO_4 acid with and without addition of KCIO_3 as an oxidant. The crude yellow cake was precipitated from the resulting green solution of phosphoric acid as Na_2U_2O_7 and (NH_4)_2U_2O_7 and subsequently purified by TBP extraction (tributylphosphate) and hydrogen peroxide as UO_4.2H_2O. TBP purified product was dried and calcined to UO_3 whereas UO_4.2H-2O was dried and reduced to UO_3 by Na_2S_2O_3. Prior to precipitation of crude yellow cake, Fe in the phosphoric acid solution was precipitated using magnesia. Elemental analysis has shown that the ore is rich in Ca and deficient in elements of potential interest ...
2005-03-01
National Emission Standards for Hazardous Air Pollutants submittal -- 1994
Energy Technology Data Exchange (ETDEWEB)
This report focuses on air quality at the Nevada Test Site (NTS) for 1994. A general description of the effluent sources are presented. Each potential source of NTS emissions was characterized by one of the following: (1) by monitoring methods and procedures previously developed at NTS; (2) by a yearly radionuclide inventory of the source, assuming that volatile radionuclides are released to the environment; (3) by the measurement of tritiated water concentration in liquid effluents discharged to containment ponds and assuming all the effluent evaporates over the course of the year to become an air emission; or (4) by using a combination of environmental measurements and CAP88-PC to calculate emissions. Appendices A through J describe the methods used to determine the emissions from the sources. These National Emission Standards for Hazardous Air Pollutants (NESHAP) emissions are very conservative, are used to calculate the effective dose ...
1995-06-01
Theoretical considerations for X-ray phase contrast mammography by Thomson source
Energy Technology Data Exchange (ETDEWEB)
The advent, in the near future, of compact X-ray sources like Thomson Back-Scattering (TBS) will allow the clinical application of advanced X-ray imaging techniques, such as phase contrast, with higher sensitivity and lower impact in terms of dose delivery. In this work, we theoretically investigated the possibility of using such sources for phase contrast imaging of micro-calcifications included in a breast tissue. In our study we analyzed the phase and amplitude distribution of the TBS source and we showed that this source can be used for phase contrast imaging since the source coherence at the sample position is sufficiently high for achieving good contrast and micrometer spatial resolution. Indeed the spatial coherence of a TBS source is closer to that of a synchrotron radiation source, and much better than that of a laboratory source. Moreover, we showed the advantages of phase imaging with respect to standard absorption imaging, in the ...
2009-09-01
The work of the CONRAD task group 5.2: research studies on biokinetic models.
The objective of this Task Group is the coordination of research studies on biokinetic models and the evaluation of the implications of new biokinetic models on dose assessment and safety standards. For this the new ICRP models, which will be used for a revision of ICRP Publications 30, 54, 68 and 78, are implemented into six different computer codes in five European countries and quality assured by intercomparison procedures. The work has started with the implementation of the new ICRP Alimentary Tract Model. New systemic models and the new NCRP wound model will follow. The work also includes the evaluation of experimental results in terms of formulation by the new model structures and a quality assurance of model formulation. PMID:17556343
2007-06-07
Response to measles-mumps-rubella vaccine in children on dialysis.
Ten children receiving maintenance dialysis were immunized with the standard dose of measles-mumps-rubella vaccine between 15 and 33 months of age. Immune responses to vaccination were determined using commercially available enzyme-linked immunosorbent assays for measles, mumps, and rubella viruses. Eight children responded to measles vaccine, 5 to mumps vaccine, 8 to rubella vaccine, and only 3 children to all three vaccines, compared with a seroconversion rate of over 90% to all three vaccines in healthy children (P less than 0.0001). We contend that the relatively poor immunocompetence of our dialysis patients explains their less than optimal vaccine response and suggest that children vaccinated while undergoing dialysis be tested to confirm serological evidence of immunity. PMID:1571219
1992-03-01
International Nuclear Information System (INIS)
A Quantitative Computed Tomography (QCT) method, simplifying the well-known technique proposed by Genant (1982) and applied to a standard third generation whole body CT scanner is described. This technique was applied in the measurement of the trabecular bone which has high sensitivity for metabolic changes. The BMC (Bone Mineral Content) measured in different groups of subjects (healthy postmenopausal patients versus women with postmenopausal osteoporosis) showed a highly significant difference (p<0.001). The precision of repositioning (coefficient of variation 1.8% to 2.3%, obtained in healty male patients) and the good, linear relationship computed from the phantom values, minimize measurement errors. Since this method is quickly applied and involves low-dose radiation-exposure, it could be introduced in the clinical study of metabolic bone diseases.
1987-01-01
Pharmacological treatment of primary negative symptoms in schizophrenia: A systematic review
British Library Electronic Table of Contents (United Kingdom)
BackgroundOptimal treatment of primary negative symptoms is important because their presence is associated with poor outcome.AimsTo systematically review all studies dealing with the efficacy of pharmacological agents on primary negative symptoms.MethodA comprehensive search of the relevant literature was undertaken using electronic database, reference lists and personal contact.ResultsThere is a lack of standardized research designs. Amisulpride is the most extensively studied drug with respect to efficacy against primary negative symptoms. At low doses it demonstrates a consistent, modest effect compared to placebo, though not to conventional antipsychotics and has yet to be tested against other atypicals. Evidence from multiple studies that used simple statistical analyses and inclusion...
2006-01-01
Pentobarbital anesthesia alters neural responses in the precedence effect
British Library Electronic Table of Contents (United Kingdom)
The precedence effect (PE) is thought to be beneficial for proper localization and perception of sounds. The majority of recent physiological studies focus on the neural discharges correlated with PE in the inferior colliculus (IC). Pentobarbital anesthesia is widely used in physiological studies. However, little is known of the effect of pentobarbital on the discharge of neurons in PE. Neuronal responses in the IC from 23 male SD rats were recorded by standard extracellular recording techniques following presentation of 4ms white noise bursts, presented from either or both of two loud speakers, at different interstimulus delays (ISDs). The neural responses were recorded for off-line analysis before or after intraperitoneal administration of pentobarbital at a loading or maintenance dose. ...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
The high sensitivity of CaSO{sub 4}: Dy as a thermoluminescent material is a great advantage when dealing with low dose levels, as in diagnostic radiology procedures. However, these kinds of dosemeters present a high energy dependence that must be precisely determined in the energy range of interest. Dosimetric pellets of CaSO{sub 4}: Dy are produced at IPEN since the end of the 80 Th decade. These pellets are produced in three forms: conventional CaSO{sub 4}: Dy (50 mg); thin CaSO{sub 4}: Dy (20 mg) and CaSO{sub 4}: Dy + 10% C (20 mg). The main applications of these dosemeters are in personal and environmental dosimetry. In this study, CaSO{sub 4}: Dy pellets produced at IPEN were evaluated in diagnostic radiology standard beams. These qualities are based on the IEC 61267 standard, and they were established at an industrial X-ray system Pantak/Seifert, model ISOVOLT 160HS. Former studies evaluated CaSO{sub 4}: Dy of ...
2006-07-01
Radiation receiver. Strahlungsempfaenger
Energy Technology Data Exchange (ETDEWEB)
The purpose of the invention is to improve a radiation receiver, consisting of a hollow body with an opening for the entry of radiation and a ceramic absorber situated in the hollow body, which absorbs the radiation energy entering through the opening, and emits it as thermal radiation to a heat medium, so that a higher efficiency can be achieved. According to the invention, the problem is solved by the fact that the absorber consists of ceramic material on the side towards the solar radiation, which has a low emission value and a high absorption value, and that the side of the absorber towards the heat medium has ceramic material of high emission value and low absorption value. This ensures that reradiation is prevented near the opening of the hollow body, and that the solar energy entering is largely absorbed in the hollow body.
1981-10-01
Optical effects of fine-particle carbon on urban atmospheres
Energy Technology Data Exchange (ETDEWEB)
The effects of fine-particle C, such as diesel soot, on the optical properties of urban haze in the visible wavelength range were explored to determine the dominant effects and to see if simple parameters (such as visual range in green) provide an adequate measure of these effects. It is known that fine-particle C absorbs more strongly in the blue than in the red, so that when it is mixed with a white pigment, the resulting gray can appear somewhat brown. The possibility of a similar effect in urban hazes was investigated, but found not to occur. When the sun is overhead, the near-horizon sky chromaticities caused by mixtures of fine-particle C and non-absorbing aerosol can also be produced by non-absorbing aerosols alone. It is shown that absorbing aerosol will darken the horizon sky, and a simple equation for the radiance of the horizon sky is derived. The effect of absorbing ...
1986-01-01
Application of dose factors for decay chains
International Nuclear Information System (INIS)
... dose rates inhalation iodine 134 krypton 88 nuclear decay quality factor
International Nuclear Information System (INIS)
In an epidemiological study of the somatic late effects risk following incorporation of a short lived #alpha#-emitter, 1473 ankylosing spondylitis patients treated with repeated intravenous injections of "2"2"4Ra in the years 1948 - 75, have been observed in the GSF. The usual therapeutic plan consisted of a total of 10 - 12 injections of 1.036 MBq (28 #mu#Ci) of "2"2"4Ra each, given at weekly intervals; this would result in an cumulative #alpha#-dose of 0.56 - 0.67 Gy to the marrow-free skeleton of a 70-kg-man (standard man). These patients have been followed together with a control group of ankylosing spondylitis patients not treated with radioactive drugs and/or X-rays. Until May 1993 (mean follow-up time 19.9 yr), 595 patients of the exposure group and 722 patients of the control group have died, causes of death have been ascertained for 578, resp. 668 patients. Among others we observed in the exposure group 10 cases of leukaemia (vs. 2.7 - ...
1993-09-28
An integrated Tomographic Gamma Scanning system for non-destructive assay of radioactive waste
Energy Technology Data Exchange (ETDEWEB)
The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm{sup -3} or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant applications. Many of the design features and the end application itself set these TGS ...
2007-08-21
An integrated Tomographic Gamma Scanning system for non-destructive assay of radioactive waste
International Nuclear Information System (INIS)
The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm"-"3 or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant applications. Many of the design features and the end application itself set these TGS systems ...
2007-08-21
Energy Technology Data Exchange (ETDEWEB)
To determine a suitable combination of X-ray filter and tube kilovoltage for Fuji Computed Radiography (FCR), provide better detection of pulmonary nodules, and reduce patient exposure, we compared observer performance with different X-ray filters and tube voltages. Radiographs were obtained with a copper filter backed by aluminium, with a tungsten filter backed by yttrium and aluminium, and with a lead filter backed by yttrium and aluminium, at both 100 kVp and 135 kVp. Observer performance in detecting simulated lung nodules, which were placed on the posterior aspect of a chest phantom, was compared using receiver operating characteristic (ROC) techniques for each combination of the X-ray filter and tube voltage. The results of the study indicated that (1) nodule detection was superior for the images obtained with 135 kVq as compared with 100 kVp; (2) approximately equal detection rates were obtained for the three X-ray filter sets, although results with the tungsten filter were ...
1994-10-01
International Nuclear Information System (INIS)
To determine a suitable combination of X-ray filter and tube kilovoltage for Fuji Computed Radiography (FCR), provide better detection of pulmonary nodules, and reduce patient exposure, we compared observer performance with different X-ray filters and tube voltages. Radiographs were obtained with a copper filter backed by aluminium, with a tungsten filter backed by yttrium and aluminium, and with a lead filter backed by yttrium and aluminium, at both 100 kVp and 135 kVp. Observer performance in detecting simulated lung nodules, which were placed on the posterior aspect of a chest phantom, was compared using receiver operating characteristic (ROC) techniques for each combination of the X-ray filter and tube voltage. The results of the study indicated that 1) nodule detection was superior for the images obtained with 135 kVq as compared with 100 kVp; 2) approximately equal detection rates were obtained for the three X-ray filter sets, although results with the tungsten filter were ...
1994-01-01
Self-expandable stent loaded with {sup 125}I seeds: Feasibility and safety in a rabbit model
Energy Technology Data Exchange (ETDEWEB)
Objective: To evaluate technical feasibility and acute and subacute radiotolerance of a self-expandable stent loaded with {sup 125}I seeds in the rabbit esophagus. Methods: A self-expandable stent designed for esophageal application was made of 0.16 mm nitinol wire and loaded with {sup 125}I seeds (CIAE-6711). Twenty-seven stents with three different radioactive dosages (n = 9 in each dosage group) were implanted in the esophagus of healthy rabbits, while nine stents alone were used as controls. The stents were perorally deployed into the esophagus under fluoroscopic guidance. Radiological follow-up included plain chest film, CT scan, and barium esophagography which were undertaken in all rabbits of each group at 2, 4, and 8 weeks, respectively, which were correlated to histopathological findings. The stented esophageal segments along with their adjacent tissues were harvested for histopathological examinations. Results: The stent was successfully deployed into the targeted esophageal ...
2007-02-15
Radioactive lead studies in the human
International Nuclear Information System (INIS)
The differing susceptibility of individuals to the toxic effects of chronic lead exposure has never been fully understood. As the major intake of lead in the human is from food and beverages, any variation between individuals of the quantity of lead absorbed from the gut, and of the distribution and excretion of this lead, may account for the differences in individual susceptibility. The food and beverages themselves may have an influence, and to investigate their effects on absorption, distribution and excretion of lead, experiments were performed on normal subjects using a short lived radionuclide of lead, "2"0"3Pb, and instruments generally available in Nuclear Medicine. Lead absorption between different individuals showed a wide variation when "2"0"3Pb was taken as a single dose between meals. Minerals were found to be mainly responsible for affecting absorption when one subject ingested "2"0"3Pb in control meals from which one dietary ...
International Nuclear Information System (INIS)
The mechanism of lead transport is presented, and especially the particular similarities or dissimilarities between lead and calcium in this process. The absorption of these metals was determined cockerels, raised on a commercial diet or on a specified diet, using in vivo ligated loop procedure. The dose administered into the loop contained 0.5 #mu#Ci "2"0"3Pb (and/or 0.1 #mu#Ci "4"7Ca), and 0.01 mM lead acetate (and/or mM CaCl_2) in 0.5 ml 0.15 M NaCl,pH 6.5. It was shown that lead is rapidly taken up by the mucosal tissue, and slowly transferred into the body, whereas less calcium is retained by the tissue and the transfer of calcium is many times as effective as that for lead. They appear to respond in a similar manner to a low calcium intake and vitamin D treatment. Increasing luminal stable lead concentration significantly reduced the percentage of radiolead significantly reduced the percentage of radiolead absorbed, but did not affect the ...
International Nuclear Information System (INIS)
Natural radioactive materials under certain conditions can reach hazardous radiological levels. The natural radionuclide ("2"3"8U, "2"3"2Th, "4"0K) contents of rock samples at various locations in the North Tushki area were investigated using gamma-spectrometric analysis. Estimates of the measured radionuclide content have been made for the absorbed dose rate of gamma radiation. The equivalent radium (R_e_q) and the external hazard index (H_e_x) which resulted from the natural radionuclides in soil are also calculated and tabulated. The studied samples have been collected from various rock exposures in the North Tushki area. The distribution of major oxides, U and Th were studied. It is found that the enrichment and depletion of the major oxides are mainly due to the effect of hydrothermal alteration, which caused mobility of some major oxides, which increases some elements and decreases others. It is important to mention that the study area is ...
2002-09-01
Energy Technology Data Exchange (ETDEWEB)
Two neutron emesis experiments were conducted at the Armed Forces Radiobiology Research Institute (AFRRI). In both experiments (described as Phase I and Phase II) the radiation dose required to cause emesis in 50% of subjects (ED50) was determined for both neutron reactor and gamma reactor source radiation. Emesis onset, offset and duration times post-exposure are reported. Neutrons were maximized from the reactor by passing the beam through a 15.25 cm (6 in.) thick lead wall to filter out gamma photons. Gamma rays were maximized by thermalizing neutrons in 30.5 cm (12 in.) of water, then absorbing the thermal neutrons in a gadolinium-cadmium shield. In Phase I, 28 dogs were exposed to radiation: 12 were exposed to gamma photons at the rate of 0.69 Gy/min and 16 were exposed to neutrons at 1.2 Gy/min. In Phase II, 58 dogs in 3 groups were exposed to radiation: 19 were exposed in the gamma group at 0.75 Gy/min, 20 were exposed in the undrugged ...
1985-08-01
Effect of vitamin D on the intestinal absorption of 203Pb and 47Ca in chicks
Energy Technology Data Exchange (ETDEWEB)
The transfer of 203Pb and/or 47Ca across the intestinal epithelium of the chick was investigated, with emphasis given to the functional role of cholecalciferol (vitamin D-3). 203Pb, after introduction in the intestinal lumen, is rapidly accumulated by the intestinal tissue, and only a fraction of 203Pb is translocated parenterally (absorbed). Cholecalciferol did not significantly affect the accumulation of 203Pb by intestinal tissue but did accelerate 203Pb movement across the basal-lateral membrane. In contrast, cholecalciferol both decreased 47Ca tissue levels and increased 47Ca absorption. In rachitic chicks, the rate of absorption of 203Pb was greater in the distal than in the proximal segments of the intestine; after cholecalciferol repletion, the degree of absorption in al segments was similar, indicting the order of cholecalciferol effectiveness as duodenum greater than or equal to jejunum greater than ileum. An acute dose of 1,25(OH)2D3 ...
1982-03-01
Effect of vitamin D on the intestinal absorption of /sup 203/Pb and /sup 47/Ca in chicks
Energy Technology Data Exchange (ETDEWEB)
The transfer of /sup 203/Pb and/or /sup 47/Ca across the intestinal epithelium of the chick was investigated, with emphasis given to the functional role of cholecalciferol (vitamin D-3). /sup 203/Pb, after introduction in the intestinal lumen, is rapidly accumulated by the intestinal tissue, and only a fraction of /sup 203/ Pb is translocated parenterally (absorbed). Cholecalciferol did not significantly affect the accumulation of /sup 203/Pb by intestinal tissue but did accelerate /sup 203/Pb movement across the basal-lateral membrane. In contrast, cholecalciferol both decreased /sup 47/Ca tissue levels and increased /sup 47/Ca absorption. In rachitic chicks, the rate of absorption of /sup 203/Pb was greater in the distal than in the proximal segments of the intestine; after cholecalciferol repletion, the degree of absorption in all segments was similar, indicating the order of cholecalciferol effectiveness as duodenum greater than or equal to jejunum > ileum. ...
1982-03-01
Radioactive iodine absorbing properties of tetrathiafulvalene
Energy Technology Data Exchange (ETDEWEB)
For the purpose of searching some effective absorbents of gaseous radioactive iodine, 16 substances considered as having an affinity for iodine were investigated with regular iodine and /sup 125/I. In a preliminary survey, only tetrathiafulvalene (TTF) was found to have satisfactory absorbing properties comparable to activated charcoal. A further detailed comparison of the properties between TTF and activated charcoal led us to the conclusion that the former has more preferable properties as absorbent of radioactive iodine than the latter in all points studied. The results are summarized as follows: (1) The absorption of iodine on TTF in atmosphere was about twice as much as that on activated charcoal. Desorption of iodine from saturatedly absorbed iodine on TTF was practically negligible except trace amount of initial desorption, while that on activated charcoal was considerable (3%/50h) even in the ...
1989-05-01
An Introduction to the Standard Theory of Electroweak Interactions (4/4)
An Introduction to the Standard Theory of Electroweak Interactions (4/4)
2011-01-01
An Introduction to the Standard Theory of Electroweak Interactions (3/4)
An Introduction to the Standard Theory of Electroweak Interactions (3/4)
2011-01-01
An Introduction to the Standard Theory of Electroweak Interactions (2/4)
An Introduction to the Standard Theory of Electroweak Interactions (2/4)
2011-01-01
International Nuclear Information System (INIS)
The objective of this study was to explore the role of three-dimensional (3-D) rotational angiography (RA) of the inferior vena cava (IVC; 3-D CV) before filter retrieval and its impact on treatment planning compared with standard anteroposterior cavography (sCV). Thirty patients underwent sCV and 3-D CV before IVC filter retrieval. Parameters assessed were: projection of filter arms or legs beyond the caval lumen, thrombus burden within the filter and IVC, and orientation of the filter within IVC. Skin and effective radiation doses were calculated. Statistical analysis was performed using paired Student t test and nonparametric McNemar's test. Standard anteroposterior cavography detected 49 filter arms or legs projecting beyond the caval lumen in 25 patients. Three-dimensional CV demonstrated 89 filter arms or legs projecting beyond the caval lumen in 28 patients. Twenty-two patients had additional filter arms or legs ...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
ABSTRACT-Here we identify release of annexin A2 into the culture medium in response to low dose X-ray radiation exposure and establish functional linkages to an established paracrine factor-mediated anchorage-independent growth response. Using a standard bicameral coculture model, we observe that annexin A2 levels associated with non-irradiated neighboring cells seeded in the lower chamber (annexin A2 silenced [shRNA] JB6 cells) are increased upon coculture with irradiated (10-50 cGy) JB6 cells seeded in the upper chamber, relative to coculture with sham exposed JB6 cells seeded in the upper chamber, suggesting that annexin A2 released into the medium is capable of communicating in a paracrine fashion. Using a previously established coculture model, we observed that the paracrine factor-mediated anchorage-independent growth response to low dose X-ray radiation is markedly reduced when irradiated annexin A2 silenced (shRNA) ...
2009-07-13
Energy Technology Data Exchange (ETDEWEB)
Numerous laboratory investigations have shown that sulfur dioxide (SO/sub 2/) induces bronchoconstriction and respiratory symptoms in exercising asthmatics. These effects appear to depend on dose rate (the product of exposure concentration and ventilation rate), and may occur at dose rates attainable during outdoor exercise in SO/sub 2/-polluted communities. Effects are rapid in onset, requiring no more than 5 min of exercise during exposure. Thus they may be induced by transient elevations of SO/sub 2/ levels, which may occur near large pollution sources even when longer-term average concentrations meet existing air quality standards. Even very mild asthmatics typically are far more sensitive to SO/sub 2/ than healthy volunteers. The authors discuss an investigation designed to expand and improve the dose-response information on SO/sub 2/. In comparison to earlier work it employed a larger, clinically ...
1987-01-01
Pentobarbital anesthesia alters neural responses in the precedence effect.
The precedence effect (PE) is thought to be beneficial for proper localization and perception of sounds. The majority of recent physiological studies focus on the neural discharges correlated with PE in the inferior colliculus (IC). Pentobarbital anesthesia is widely used in physiological studies. However, little is known of the effect of pentobarbital on the discharge of neurons in PE. Neuronal responses in the IC from 23 male SD rats were recorded by standard extracellular recording techniques following presentation of 4 ms white noise bursts, presented from either or both of two loud speakers, at different interstimulus delays (ISDs). The neural responses were recorded for off-line analysis before or after intraperitoneal administration of pentobarbital at a loading or maintenance dose. Data were assessed by one-way repeated measures analysis of variance and pairwise comparisons. When the ipsilateral stimuli were leading, pentobarbital at a ...
2011-05-06
International Nuclear Information System (INIS)
The effect of measurement geometry on the determination of the activity of solutions containing "1"2"5I for use in brachytherapy applications has been investigated for 5 mL plastic syringes and 2 mL conical glass dose vials as a function of filling mass. New dial settings for the syringes over a filling mass range of 1 to 3 g have been determined to be 497#+-#8 and 469#+-#8 (expanded, k=2, uncertainties) for the NIST Capintec CRC-12 and Capintec CRC-35R, respectively, with any effect due to the filling mass lying within the uncertainty in the activity calibration. A filling mass effect was observed in the dose vials, causing a 10.5% reduction in the chamber response from a 2 g filling mass to 1 g. Dial settings at 2 g were experimentally found to be 143#+-#2 and 135#+-#2 (expanded uncertainties) for the NIST Capintec CRC-12 and Capintec CRC-35R, respectively. The appropriate dial settings for the same vials with a 1 g filling mass were found to ...
2002-07-01
A campaign of discrete radon concentration measurements in soil of Niska Banja town, Serbia
Energy Technology Data Exchange (ETDEWEB)
The first radon soil gas survey in Serbia, using passive detectors (SSNTD, CR-39), was carried out in June 2005 at field sites in Niska Banja town. The aim of the survey was to identify risk zones characterised by high levels of this radioactive gas. Radon measurements were made at the depth of 50 cm, in the ground according to a systematic grid pattern. Furthermore, at all 48 measurement points, the surface gamma dose rates in the air was also measured at the same locations and soil samples were collected for gamma spectrometric analysis for the radionuclides {sup 226}Ra, {sup 228}Th and {sup 40}K. Radon concentrations were found to range from 1270 to 155000Bqm{sup -3} with an average of 33765Bqm{sup -3} and a median value of 12626Bqm{sup -3}. The geometrical mean value and geometrical standard deviation were calculated as 16160Bqm{sup -3} and 3.5Bqm{sup -3}, respectively. Gamma dose rate varies from 92 to 316nGyh{sup -1}, ...
2007-11-15
A campaign of discrete radon concentration measurements in soil of Niska Banja town, Serbia
International Nuclear Information System (INIS)
The first radon soil gas survey in Serbia, using passive detectors (SSNTD, CR-39), was carried out in June 2005 at field sites in Niska Banja town. The aim of the survey was to identify risk zones characterised by high levels of this radioactive gas. Radon measurements were made at the depth of 50 cm, in the ground according to a systematic grid pattern. Furthermore, at all 48 measurement points, the surface gamma dose rates in the air was also measured at the same locations and soil samples were collected for gamma spectrometric analysis for the radionuclides "2"2"6Ra, "2"2"8Th and "4"0K. Radon concentrations were found to range from 1270 to 155000Bqm"-"3 with an average of 33765Bqm"-"3 and a median value of 12626Bqm"-"3. The geometrical mean value and geometrical standard deviation were calculated as 16160Bqm"-"3 and 3.5Bqm"-"3, respectively. Gamma dose rate varies from 92 to 316nGyh"-"1, with an average of 132nGyh"-"1. ...
2007-11-01
[Determination of sulfite in flue gas desulfurization with seawater by ion chromatography].
The technology for flue gas desulfurization (FGD) with seawater is widely adopted by coal-fired power plants in coastal areas. SO2 in the flue gas is absorbed by alkaline seawater and transfered in aqueous phase as sulfite (SO3(2-)), and most SO3(2-) is transformed to sulfate (SO4(2-)) after an aeration process. The remaining SO3(2-) in the seawater discharged to sea area may be harmful to marine organism because of its biological toxicity, thus it is necessary to determine the concentration of SO3(2-) in the seawater for desulfurization. In this study, the method of determination of SO3(2-) in the seawater by ion chromatography was investigated. The separation was achieved on an IonPac AS14A column with 14 mmol/L NaOH-12 mmol/L Na2 CO3 solution as the mobile phase at a flow rate of 1.2 mL/min, and the detection was performed by a pulsed amperometric detector. Formaldehyde was added as a protective agent when sampling because the SO3(2-) is easy to be oxidized. To ...
2009-11-01
Energy Technology Data Exchange (ETDEWEB)
The ternary compound CuInS{sub 2} is attractive for solar cells due to its band gap of 1.54 eV which borders the optimum value necessary for conversion of a solar spectrum. Recently, works on thin film cells based on this material (ZnO/CuInS{sub 2}) has been reported to show efficiency as high as 11.4%. In this paper, the orientation and the morphology of CuInS{sub 2} sprayed films are determined by the means of X-ray diffraction and scanning electron microscopy. Sprayed CuInS{sub 2} films deposited onto a transparent Pyrex substrate with standard fabrication parameters show a chalcopyrite structure with a preferential orientation (1 1 2). A model based on the calculation of the relative dielectric function {epsilon} has been performed in order to obtain the profile of variation of this parameter and to understand the optical behavior of this material via its transmittance and reflectance in visible and near-infrared regions (0.35-2.5 {mu}m). In the same way, ...
2009-07-29
International Nuclear Information System (INIS)
The ternary compound CuInS2 is attractive for solar cells due to its band gap of 1.54 eV which borders the optimum value necessary for conversion of a solar spectrum. Recently, works on thin film cells based on this material (ZnO/CuInS2) has been reported to show efficiency as high as 11.4%. In this paper, the orientation and the morphology of CuInS2 sprayed films are determined by the means of X-ray diffraction and scanning electron microscopy. Sprayed CuInS2 films deposited onto a transparent Pyrex substrate with standard fabrication parameters show a chalcopyrite structure with a preferential orientation (1 1 2). A model based on the calculation of the relative dielectric function ? has been performed in order to obtain the profile of variation of this parameter and to understand the optical behavior of this material via its transmittance and reflectance in visible and near-infrared regions (0.35-2.5 ?m). In the same way, considering the inhomogeneous material ...
2009-07-29
Gas evolution in aluminum electrolytic capacitors
Gas evolution in aluminum electrolytic capacitors constitutes one of their main drawbacks in comparison to other types of capacitors lacking a liquid electrolyte. In this respect, one of the most common causes of failure shown by liquid electrolyte capacitors is electrolyte leakage through the seal or even explosions produced by internal pressure buildup. In order to prevent these hazards, some substances, known as depolarizers, are usually added to the capacitor electrolyte with the purpose of absorbing the hydrogen evolved at the cathode (1, 2). Although the gas evolution problem in electrolytic capacitors has been known for a long time, there is a lack of literature on both direct measurements of the gas evolved and assessments of the amount of depolarizer active for the hydrogen absorption process. Aluminum electrolytic capacitors of 100..mu..F and 40V nominal voltage, miniature type (diam 8 mm, height 18.5 mm), were manufactured under ...
1984-03-01
Development of next-generation light water reactor in Japan
International Nuclear Information System (INIS)
In Japan, the development of next-generation Light Water Reactor has been launched since April 2008. The development program will be completed in 2015. The purpose of development is to cope with the replacement for existing nuclear power plants after 2030 in Japan and the expanding demand for nuclear power in the world; 'Nuclear Renaissance.' The reactor also aims to be global standard at around 2030. The requirements for global standard and domestic users have been investigated through the feasibility study of past 2 years, 2006-2007, and six innovative features or 'Core-Concepts' were established as follows. A) Reactor core system with uranium enrichment above 5% for significant decrease of spent fuel discharge and prominent higher availability B) Long-life materials and innovative water chemistry technologies for 80 years plant lifetime and significant reduction of occupational dose C) Seismic isolation technologies to ...
2009-10-27
Carbon dioxide absorption methanol process
Energy Technology Data Exchange (ETDEWEB)
This patent describes a process for removing carbon dioxide from a feed stream of natural gas having at least methane, ethane and heavier. It comprises: first, separating the feed stream in a first separator to form a first stream having substantially all of the propane and heavier hydrocarbons and carbon dioxide and ethane and a second stream, having methane, carbon dioxide and ethane; separating the second stream in a second separator into a stream of carbon dioxide product and a third stream having ethane, methane and carbon dioxide: mixing at least a portion of the third stream with a polar compound; stream after the mixing in an absorber; separating the vapor and liquid of the third stream after the mixing in an absorber; absorbing the remaining unabsorbed carbon dioxide in a lean portion of the polar compound in the absorber, the absorber carbon dioxide and ethane with the ...
1989-08-29
Shock absorber for the leg structure of offshore jack-up rig
Energy Technology Data Exchange (ETDEWEB)
A shock absorber mechanism and method for use on the leg structure of a jack-up offshore drilling rig is described. It is mounted on the bottom of each existing leg of a drilling rig and comprises a pointed piston member which is positioned on the bottom of the leg structure and projects downwards through the can/footing of the rig leg. The piston member is held in place by a resilient tension member which is designed to absorb shock forces during vertical/axial impact of the leg structure when contact is made with the ocean floor. (author).
1992-02-19
Application properties of AB{sub 2}-type hydrogen absorbing alloys
Energy Technology Data Exchange (ETDEWEB)
Use of hydrogen absorbing alloys in various practical applications is always connected with the problem of production of starting alloys. The transition from laboratory samples to small-scale production involves the change of furnace and its operation mode and this has an effect on the preparation method of mixture of starting metal. Also, for some applications such as thermosorption compressors the exact values of thermodynamical parameters of reaction are needed. In the present work we present the results of investigation of series Laves phase hydrogen-absorbing alloys which can be promising in for use in different devices. 1 ref.
1998-07-01
International Nuclear Information System (INIS)
Full text: Thermoluminescence (TL) is a phenomenon of light emission caused by heating a pre-irradiated material. When ionizing radiation hits a TL material, electrons are freed from some atoms and moved in the material, leaving behind 'holes' of positive charge. Subsequently when the TL material is heated, the electrons and the 'holes' re-combine, and release the extra energy in the form of light. The light intensity can be measured, and related to the amount of energy initially absorbed through exposure to the ionizing radiation. In nineteen sixties thermoluminescence dosimeters (TLD) became popular for dosimetric applications in view of their small size, sensitivity and accuracy. Consequently, in early seventies, several countries started adopting of TLD for personnel monitoring. The idea of introducing TLD to replace the then prevalent film dosimeter for personnel monitoring in India was mooted and successfully implemented by Dr. K G Vohra. Limitations of ...
Target stations and beam dumps for the CERN SPS
International Nuclear Information System (INIS)
The design of the absorber blocks for internal and external dumping of the SPS proton beam is discussed. In addition, the external target stations for slow and fast extracted proton beams are described.
1977-03-16
Semiactive field-controllable magneto-rheological fluid dampers for mountain bicycles
This paper presents the development and evaluation of field- controllable, semi-active magneto-rheological fluid (MRF) shock absorbers for a mountain bicycle. Recent trends in the bicycle industry show a movement towards semi-active suspension systems. Two new MRF dampers are designed and tested with the intent of being used on the front and rear suspension of a modern mountain bicycle. The MRF shock absorbers are designed to emulate the performance of the original equipment manufacturer shock absorbers in passive mode. Application of an input electric current to the MRF shock absorber causes a dramatic increase in the damping capacity. Procedures and results are presented for the design and experimental characterization of these MRF dampers.
2000-06-01
Root Cause Analysis, Tank Fire Problem, M1A1 Main Battle ...
... ammunition is stored. Combustible cartridge cases could absorb moisture, swell, and not chamber properly. Additionally, moisture ...
1989-02-01
Power efficiency for very high temperature solar thermal cavity receivers
This invention is an improved solar energy cavity receiver for exposing materials and components to high temperatures. The receiver includes a housing having an internal reflective surface defining a cavity and having an inlet for admitting solar radiation thereto. A photothermal absorber is positioned in the cavity to receive radiation from the inlet. A reflective baffle is positioned between the absorber and the inlet to severely restrict the re-radiation of energy through the inlet. The front surface of the baffle defines a narrow annulus with the internal reflective surface of the housing. The front surface of the baffle is contoured to reflect incoming radiation onto the internal surface of the housing, from which it is reflected through the annulus and onto the front surface of the absorber. The back surface of the baffle intercepts infrared radiation from the front of the absorber. With this ...
1984-01-01
Power efficiency for very high temperature solar thermal cavity receivers
Energy Technology Data Exchange (ETDEWEB)
This invention is an improved solar energy cavity receiver for exposing materials and components to high temperatures. The receiver includes a housing having an internal reflective surface defining a cavity and having an inlet for admitting solar radiation thereto. A photothermal absorber is positioned in the cavity to receive radiation from the inlet. A reflective baffle is positioned between the absorber and the inlet to severely restrict the re-radiation of energy through the inlet. The front surface of the baffle defines a narrow annulus with the internal reflective surface of the housing. The front surface of the baffle is contoured to reflect incoming radiation onto the internal surface of the housing, from which it is reflected through the annulus and onto the front surface of the absorber. The back surface of the baffle intercepts infrared radiation from the front of the absorber. With this ...
1984-10-30
Energy Technology Data Exchange (ETDEWEB)
An emergency shutdown system for high-temperature gas-cooled pebble-bed reactors is proposed in addition to the common absorber rod shutdown system. This system is based on the strongly absorbing effect of small boronated graphite spheres (called KLAK), which trickle in case of emergency by gravity from the top reflector into the reactor core. The inner reflector of the Siemens-Argonaut reactor was substituted by an assembly of spherical Arbeitsgemeinschaft Versuchsreaktor fuel elements, and the shutdown effect was examined by installing well-defined KLAK nests inside this assembly. The purpose was to develop and prove a calculational procedure for determining criticality values for assemblies of large fuel spheres and small absorbing spheres.
1987-09-01
Influence of absorbed hydrogen on the positron lifetime spectra in Pd, Pd-Ag, Pd-Cu
International Nuclear Information System (INIS)
(1 Oct 1979). German Democratic Republic Alekseeva, OK Onishchuk, VA
1979-10-01
Improved power efficiency for very-high-temperature solar-thermal-cavity receivers
Energy Technology Data Exchange (ETDEWEB)
This invention is an improved solar energy cavity receiver for exposing materials and components to high temperatures. The receiver includes a housing having an internal reflective surface defining a cavity and having an inlet for admitting solar radiation thereto. A photothermal absorber is positiond in the cavity to receive radiation from the inlet. A reflective baffle is positioned between the absorber and the inlet to severely restrict the re-radiation of energy through the inlet. The front surface of the baffle defines a narrow annulus with the internal reflective surface of the housing. The front surface of the baffle is contoured to reflect incoming radiation onto the internal surface of the housing, from which it is reflected through the annulus and onto the front surface of the absorber. The back surface of the baffle intercepts radiation from the front of the absorber. With this arrangement, a ...
1982-04-14
British Library Electronic Table of Contents (United Kingdom)
Abstract The characteristics of desulfurization and denitrification with composite absorbent were researched through aqueous absorption experiments. The removal efficiencies of SO2 and NO were up to 100 and 95%, respectively. The composite absorbent included NaClO2 and component M. Existence of component M in the solution could reduce the absorbent cost compared with using sodium chlorite alone. Chlorine dioxide, as main reaction intermediate product, participated in oxidation reaction. The optimal experimental conditions involved NaClO2 concentration of1.13 mmol/L, solution pH of 5.5, molar ratio (M/NaClO2) of 4.1, reaction temperature of 323 K. The optimal solution pH and reaction temperature were both in the required ranges of limestone-gypsum wet flue gas desulfurization (FGD) process....
2011-01-01
Energy absorbers used against impact loading
International Nuclear Information System (INIS)
In the WWER-440 reactor the primary piping consists of six horizontal loops going radially from the pressure vessel, each loop having a horizontal steam generator. In this reactor type the relatively long primary piping with many curved sections requires special attention in order to successfully eliminate the consequences of the design basis accident. Emergency supports are located in appropriate places to restrict the movements of the pipe. Under normal conditions there is a gap of some centimeters between the pipe and a support so that in the pipe can be deformed freely under changing loads. This paper deals with those energy-absorbing structures used at the Loviisa Nuclear Power Plant for protection against impact loading. Places and circumstances where energy-absorbing structures are employed are specified. Development and design of impact absorber elements are discussed and impact tests are described. (Auth.).
1975-09-08
Standards and guidances for limiting ionizing radiation exposure
Energy Technology Data Exchange (ETDEWEB)
This chapter is concerned with standards and guidances for limiting radiation exposures. It is divided into three sections, each of which has several parts. Section 1: Ionizing Radiation -- Standards and Guidances Applicable to the Public: Part A, Radiation Protection Standards; Part B, Environmental Radiation Standards; Part C, Exempt Levels of Radioactivity; Part D, Protective Action Guides for Accidents. Section 2: Ionizing Radiation -- Standards Applicable to the Workplace. Section 3: Medical and Other Standards.
1992-12-31
On new methods for standardization of samples in activation analysis of biological materials
International Nuclear Information System (INIS)
New standardization techniques of samples in multielement instrumental neutron-activation analysis (INAA) of biological materials (BM) are considered. New methodical developments of sample preparation techniques, BM tableting, creation of comparison standards and standardization of packing material are suggested. Correlated data on concentration of different elements in standard specimens-comparison standards are presented for mass INAA, that is: for phenol-formaldehyde resin-base and human blood-base synthetic standards. 7 refs.; 3 tabs.
1988-06-26
Method of describing dose distributions in computer design of teleradiotherapy
International Nuclear Information System (INIS)
Method for description of X-ray radiation dose distribution based on semiempirical description of dose fields is suggested. At that dose field description parameters can be easily individualized for concrete X-ray device.
Examples are used to demonstrate that a shift in the point of emphasis is necessary with regard to radiation hazard in medicinal X-ray diagnosis. The parameters employed in this study to calculate somatic dose (SD) and somatically significant dose (SSD) m...
1980-01-01
The stability of biological standards
UK PubMed Central (United Kingdom)
The authors emphasize the importance of stability in biological standards and discuss the steps taken to ensure the stability of International Standards and the theoretical basis of the various stability...Full Text Available
1956-01-01
Standardization of Ajmodadi churna, a polyherbal formulation
UK PubMed Central (United Kingdom)
Standardization of herbal formulations is essential in order to assess the quality of drugs, based on the concentration of their active principles. This article reports on standardization of Ajmodadi...Full Text Available
2010-03-01
Ada Compiler Validation Summary Report: Certificate Number ...
... Standards Validation Group National Computer Systems Laboratory National Institute of Standards and Technology ... STANDARD. ... (See test Ci )i3A. ...
1989-08-18
Radiation dose in computerized tomography
International Nuclear Information System (INIS)
Dosimetric studies in 80 patients examined with the tomographic device 'Somatom' are reported. The gonad doses are compared to those of conventional radiographic techniques.
The malignancy significant dose from external beam radiotherapy
International Nuclear Information System (INIS)
In the present study an estimate is made of the malignancy significant dose from external beam radiotherapy in New Zealand utilizing data obtained in a survey conducted in 1975. This survey had been designed to assess genetically significant dose. A weighted effective dose equivalent is derived from the malignancy significant dose for direct comparison with mean per capita effective dose equivalents arising from other sources of radiation. 14 refs., 1 fig., 8 tabs.
1987-01-01
Further means for reducing radiation dose during exposure of the pelvis in infants
International Nuclear Information System (INIS)
A simple dose-saving procedure for the diagnosis of congenital hip dysplasia employing a diaphragm in nearfocus position is presented. Doses to the skin and the gonads were measured with a phantom for the new and other techniques. With optimal techniques the skin dose is smaller than 2 mR and the gonadal doses lie around 0.1 mR for both male and female patients. An estimate of the dose burden from undesired radiation is appended. (orig.).
International Nuclear Information System (INIS)
Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and the screen-film system was determined for phase imaging of mammography. In order to investigate a potential for medical application of this method, we conducted evaluation of the images of the American Collage of Radiology (ACR) ...
2002-03-01
Use of a predictor for total body potassium content: application to nutrition and hypertension
International Nuclear Information System (INIS)
Total body potassium (TBK), measured at different institutions, has no reference standard for comparison. A useful reference formula, however, based on body size and age, has been derived at the Brookhaven National Laboratory. This formula was used to help calibrate a simple whole body counter for measuring total potassium and applied to nutrition and hypertension studies. A sodium iodide detector was used for counting gamma rays emitted by potassium-40 to estimate TBK. The mean ratio (+/- S.D.) of adjusted TBK measurements to predicted values was 1.002 +/- 0.047. The ratio of lean body mass estimated by the TBK measurement to that derived from skin fold thickness was 1.069 +/- 0.056. In hypertensives on low dose thiazide, the ratio of TBK measurements to predicted values was 0.994 +/- 0.052. Thus, our TBK measurements were adjusted in close agreement with a predictor formula, provided higher estimates of lean body mass than did skin fold ...
Radiological aspects of the usability of red mud as building material additive
International Nuclear Information System (INIS)
Several researchers have examined and achieved favourable results in connection with the building industry's use of red mud extracted in large quantities from the processing of bauxite. These days more and more precedence is being given to limiting the radiological dose to the population. In this study carried out in Hungary, the use of red mud, bauxite, and clay additives recommended for the production of special cements, were examined from a radiological aspect. "2"2"6Ra and "2"3"2Th activity concentrations measured in Hungarian bauxite, red mud and clay samples were significantly similar with the levels for such raw materials mentioned in international literature. Taking radiation protection aspects into consideration, none of these products can be directly used for building construction. Taking Hungarian and international values into consideration, a small amount of red mud, not exceeding 15% could be used for brick production, for example as a colouring ...
2008-02-11
Energy Technology Data Exchange (ETDEWEB)
Until recently no active treatment for advanced or metastatic gastrointestinal stroma tumors (GIST) was available. The tyrosine kinase inhibitor imatinib has revolutionized the treatment of this disease and the median overall survival now reaches 5 years. The standard dose of imatinib is 400 mg per day. Locally advanced GIST should be treated with systemic therapy prior to surgical resection. Imatinib was recently licensed for adjuvant therapy following complete surgical removal of GIST in patients with a significant risk of recurrence. (orig.) [German] Bis vor einigen Jahren existierte keine wirksame systemische Therapie fuer fortgeschrittene oder metastasierte gastrointestinale Stromatumoren (GIST). Der Tyrosinkinaseinhibitor Imatinib hat die Behandlung dieser Tumoren revolutioniert, die mediane Ueberlebenszeit liegt heute bei etwa 5 Jahren. Die Standarddosierung von Imatinib betraegt initial 400 mg/Tag. Lokal fortgeschrittene Tumoren werden ...
2009-12-15
International Nuclear Information System (INIS)
The dosimetric characteristics for a new brachytherapy seed source (I-Plant"T"M model 3600) were measured using LiF thermoluminescent dosimeters and appropriate phantom materials in conformance with the methodology and guidance provided by the AAPM Task Group 43. The I-Plant"T"M model 3600 is the successor to the I-Plant"T"M model 3500. The major difference between these sources is that the model 3600 contains a leaded-glass core to provide radio-opacity (while the model 3500 contains a silver core), which does not produce spectral contamination upon neutron activation. The dose rate constant #LAMBDA# for the model 3600 was determined to be 1.00 Gy h"-"1 U"-"1 (with a 6% overall relative standard deviation), compared to 1.01 cGy h"-"1 U"-"1 reported for the model 3500 in previous studies. The remaining dosimetric characteristics also are similar for both sources.
2005-06-01
A food basket investigation during the autumn of 1994; Matkorgsundersoekning hoesten 1994
Energy Technology Data Exchange (ETDEWEB)
During the autumn of 1994 an investigation of foodstuffs has been accomplished to assess the average intake of {sup 137}Cs by the Swedish population due to the Chernobyl accident. A standardized food basket has been collected from two grocers in 10 localities, of which the majority came from areas with the highest fallout. The estimated maximum intake of {sup 137}Cs was 815 Bq/year in the inland of the county of Vaesterbotten. The population weighted average intake for the fallout affected counties was 435 Bq/year. The rest of the county received an intake of 235 Bq/year. The population weighted average of the intake for the whole county was estimated to 274 Bq/year. From this intake the calculated body burden would be 1.3 Bq/kg for the average citizen. Whole-body measurements of a sample of the population gave 2.0 Bq/kg. A plausible explanation would be that 40% of the intake of {sup 137}Cs can have its origin from the 10% of the consumption of foodstuffs that are ...
1995-10-01
International Nuclear Information System (INIS)
The use of absorbable polyglactin 910 mesh (Vicryl) is described in a case of Ewing's sarcoma of the pelvis. An operation was performed to hold the small bowel and colon out of the pelvis for a temporary period during which radical radiotherapy was delivered. The mesh allowed the temporary displacement of bowel and obviated bowel radiation morbidity. (author).
Thermal performance of solar air collectors with a passive heat transfer augmentation technique
Energy Technology Data Exchange (ETDEWEB)
One of the main disadvantages of solar air collectors in practical applications is their relatively low efficiency. In this experimental investigation, the shape and arrangement of absorber surfaces of the collectors were reorganized to provide better heat transfer surfaces suitable for the passive heat transfer augmentation techniques. The performance of such solar air collectors with staggered absorber sheets was tested. The experimental results show that it is possible to provide 10 to 25% enhancement in the efficiency compared to the conventional solar air collectors. (authors)
2000-07-01
The trick with the heat pump; Der Trick mit der Waermepumpe
Energy Technology Data Exchange (ETDEWEB)
The brochure reports on the construction and method of operation of heat pumps: - Efficiency and temperature difference - output figure - circuit processes - saving of primary energy - monovalent and bivalent plants - absorber, earth collectors - heat recovery. (HW) [Deutsch] Die Broschuere berichtet ueber den Aufbau und die Wirkungsweise von Waermepumpen: - Wirkungsgrad und Temperaturdifferenz - Leistungszahl - Kreisprozesse - Einsparung von Primaerenergie - monovalente und bivalente Anlagen - Absorber, Erdkollektoren - Waermerueckgewinnung. (HW)
1997-12-31
Investigation of carbon dioxide absorption by absorbents impregnated with alkanol amines
Energy Technology Data Exchange (ETDEWEB)
In studying the absorption of carbon dioxide by absorbents impregnated with alkanol amines, researchers used a laboratory-scale packed column to determine the overall gas-phase mass-transfer coefficients and enhancement factors. A model derived for the mechanism of the chemical reaction taking place in the interfacial layer accounts for the effect of the reaction upon the absorption rate better than other models.
1981-01-01
Heat exchange in a multi-cavity volumetric solar receiver
Energy Technology Data Exchange (ETDEWEB)
The concept of a multi-cavity volumetric solar receiver is very attractive for the profitability of certain of its characteristics such as high efficiency and economy. The absorber is based on a pack of small ceramic cavities which intercept and absorb the inherent high solar flux reflected from an array of mirrors. Atmospheric air acts as a coolant medium when it is drawn through the pack. A model for an overall heat transfer performance of the receiver is given and numerically solved.
1991-01-01
Standardization of rules for manufacturing normal electrical equipment for mining
Energy Technology Data Exchange (ETDEWEB)
Information is provided about standardization and unification of rules for manufacturing normal electrical equipment designed for operating in underground shafts when there is no danger of explosion of gas, dust or steam. An analysis is made of the requirements included in the CEMA standard and in the state standard.
1983-01-01
Energy Technology Data Exchange (ETDEWEB)
LEDF(Large Equipment Dismantling Facility) is the solid waste processing technology development facility that carries out high-volume reduction and low dosage processing. The high-volume reduction processing of the high dose {alpha}-waste configured with combustible waste, pvc and rubber, spent ion exchange resin, and noncombustible waste have been planned the incinerating and melting facility using the in-can type high frequency induction heating in LEDF. This test is intended to clarify the design data. It was confirmed that the incinerating and melting performance, molten solid properties and exhaust gas processing performance with pilot testing equipment and bench scale equipment. The result of this test are as follows. 1. Processing speed is 6.7 kg/h for the combustible waste, 13.0 kg/h for the ion exchange resin, and 30.0 kg/h for the noncombustible waste. For above optimum processing conditions are as follows. Operating temperature is 1000degC for the ...
1999-12-01
Development of barcode system for internal dose monitoring
International Nuclear Information System (INIS)
In Tarapur Atomic Power Station unit-3 and 4, which is 540 MWe pressurized heavy water reactor, tritium is produced in primary heat transport system and moderator system. Tritium is a major contributor to the internal dose. Internal dose contributes about 30% of the collective dose. Internal dose monitoring and its control are important to control the collective dose. Estimation of internal dose is done by analysis of bioassay samples of radiation workers. In a month, about 7000 bioassay samples are analysed for the internal dose assessment during normal operation, and about 12000 during the biennial shut down of the reactor. To enhance the sample preparation and counting performance, minimize the entry errors and reduce the processing time, barcode based label generation system was developed for the internal dose ...
2008-11-19
Indoor radon dose assessment for Osijek
Energy Technology Data Exchange (ETDEWEB)
After ten years' investigation of radon's seasonal variation at three very different locations, as well as radon concentration measurements in kindergartens, schools, air-raid shelters and cellars, systematic indoor radon measurements were undertaken in dwellings (residential buildings) of Osijek (East Croatia, 130andpuncsp; omitted000 citizens). Indoor radon was measured by means of the LR-115 SSNT detector at 48 town locations that gave an arithmetic mean of 71.6 Bq/m{sup 3}, standard deviation of 44.0 Bq/m{sup 3} and geometric mean of 60.1 Bq/m{sup 3}, for the radon concentration range from 22.7 to 185.6 Bq/m{sup 3}. Radon measurements, performed by the silicon Radhome detector, did not differ significantly. The empirical frequency distribution of radon concentrations, with the class width of 20 Bq/m{sup 3}, was in accordance with the theoretical log-normal distribution which was shown with the {chi}{sup 2}-test. The radon map pointed out a ...
1999-05-01
International Nuclear Information System (INIS)
Background and purpose: In order to investigate the feasibility, toxicity and antitumor efficacy of hyperfractionated radiation therapy, 37 adult patients with incompletely resected supratentorial low-grade glioma were entered into a phase II study. Materials and methods: The radiation therapy dose was 55 Gy in 50 fractions in 25 treatment days over 5 weeks to the tumor plus a 2-cm margin, with an additional 17.6 Gy given in 16 fractions in 8 treatment days over 1.5 weeks to the tumor plus a 1-cm margin, using 1.1 Gy b.i.d. fractionation with a 6 h interfraction interval. The total tumor dose was 72.6 Gy in 66 fractions in 33 treatment days over 6.5 weeks. Results: The median survival time (MST) for all 37 patients has not yet been attained, while 5- and 7-year survival rates were 75% and 69%, respectively. The median time to tumor progression (MTP) has also not yet been attained, while 5- and 7-year progression-free survival (PFS) rates were ...
1998-10-01
International Nuclear Information System (INIS)
An analogue of hGH isolated from plerocercoids of the tapeworm Spirometra mansonoides displaces ["1"2"5I]hGH from its receptors in rabbit, rat, and hamster liver membranes. Biologically, plerocercoid growth factor (PGF) is more similar to hGH than to other mammalian GH's but has not been shown to bond human cells. Receptors specific for hGH have been described on cultured human lymphocytes (IM-9). In this study, the authors compared the binding of PGF and hGH in IM-9 cells and in rabbit hepatic membranes. IM-9 lymphocytes (12 x 10"6 cells/tube) were incubated with ["1"2"5I]hGH and increasing concentrations of hGH (ng/ml) or PGF (serial dilutions) for 90 min at 30"0 C. Specific binding (B_0 - NSB) was determined for each dose of hGH or PGF and the binding curves were analyzed by logit-log regression. The results show that PGF displaced ["1"2"5I]hGH from human cells in a dose dependent manner (r = 0.98). Based on the IM-9 assay, 1 ml of the PGF ...
1986-04-13
Development of a neutron/. gamma. ray radiation monitor
Energy Technology Data Exchange (ETDEWEB)
Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/..gamma.. ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time ..gamma.. spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded ..gamma.. spectra created by the photopeak-Compton edge combination in the plateau portion of the knee response, correcting equations using a linearized approximation to the ...
1983-01-01
Development of a neutron/#gamma# ray radiation monitor
International Nuclear Information System (INIS)
Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/#gamma# ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time #gamma# spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded #gamma# spectra created by the photopeak-Compton edge combination in the plateau portion of the knee response, correcting equations using a linearized approximation to the electron ...
1983-01-01
Development of a Neutron/gamma Ray Radiation Monitor.
Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/gamma ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time gamma spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded gamma spectra created by the photopeak-compton edge combination in the plateau portion of the knee response, correcting equations using a linearized approximation to the electron ...
1983-01-01
PRA QUALITY IN REGULATORY DECISIONS
ASME PRA STANDARD FOR PRA. FOR NPP APPLICATION. " Provides a Standard for performing and using a. PRA. Definitions. Risk assessment ...
International Nuclear Information System (INIS)
Purpose/Objective: The role of programmed cell death (apoptosis) as a cellular response to cancer therapy such as radiation or chemotherapy is the subject of much study, and manipulation of the apoptotic response in tumor cells may be valuable in the treatment of a variety of cancers. Both p53 dependent and independent apoptotic pathways have been identified; p53 is mutated in at least 50 % of human cancers and a majority of radiation resistant tumors contain p53 mutations. This study is designed to examine the induction of programmed cell death in a human colon carcinoma cell line that possesses two mutated p53 alleles. Ionizing radiation alone, or in combination with the chemotherapeutic drug 5-fluorouracil (5-FU), were used to elicit the apoptotic response. This study will focus on whether these treatments can induce a significant apoptotic response in cells that have mutated p53 alleles. Materials and Methods: HT-29 cells were assessed for clonogenic survival after being plated at ...
1996-09-01
Effective dose equivalent concept in radiopharmaceutical dosimetry
Energy Technology Data Exchange (ETDEWEB)
The Effective Dose Equivalent Concept defined by the International Commission on Radiological Protection in 1977 considers the risk from irradiation including both hereditary and somatic effects. This paper will deal with the definition of a concept for somatic effects only, the somatically significant dose equivalent. This is defined as the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by various individuals. The somatically effective dose equivalent for a particular radiopharmaceutical is the weighted sum of the average dose equivalent to various organs. The dose equivalent to various organs can be derived from an extended MIRD formalism also considering the rest of body excluding the source ...
1981-06-01
Effective dose equivalent concept in radiopharmaceutical dosimetry
International Nuclear Information System (INIS)
The Effective Dose Equivalent Concept defined by the International Commission on Radiological Protection in 1977 considers the risk from irradiation including both hereditary and somatic effects. This paper will deal with the definition of a concept for somatic effects only, the somatically significant dose equivalent. This is defined as the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by various individuals. The somatically effective dose equivalent for a particular radiopharmaceutical is the weighted sum of the average dose equivalent to various organs. The dose equivalent to various organs can be derived from an extended MIRD formalism also considering the rest of body excluding the source ...
Patient doses from medical uses of x-rays
International Nuclear Information System (INIS)
A survey to determine the annual genetically significant dose and mean bone-marrow dose to the Australian population from radiological procedures has been undertaken. For diagnostic radiology the following were carried out: determination of the frequency of a procedure; measurement of patient doses using TLD and processing of data and calculation of gonadal and bone-marrow doses.
1981-01-01
Evaluation of transient dose in conveyor type low dose irradiator
International Nuclear Information System (INIS)
In conveyor type irradiators, the movement of conveyor and the product boxes is not there until the source is fully in the irradiation position. In case the conveyor system fails the source must automatically be returned to its shielded storage vault. The dose received by the product during the movement of the source from or to the shield becomes significant if the total dose to be received by the product is small. A study has been carried out for evaluating the transient dose received by onions in the POTON irradiator. The results of the study are discussed in this paper. (author)
2003-03-05
Development of internal dose estimation software on radiation protection
International Nuclear Information System (INIS)
Objective: To develop a computerized method of internal dose estimation on radiation protection. Methods: Based on MIRD mathematic model of the organs and by means of the programming language of MS Visual Basic 6.0, a computer program of dose estimation in internal radiation was developed for radiation protection. Results: The computerized method of dose estimation for internal radiation was completed. Conclusions: This computerized method is very convenient for internal radiation dose estimation of several aspects. It can also be used in radiation accident. (authors)
2008-10-01
Collection of athermal phonons into doped Ge thermistors using quasiparticle trapping
Energy Technology Data Exchange (ETDEWEB)
We have developed a low-temperature particle detector that uses a novel quasiparticle trapping mechanism to funnel athermal phonon energy from an 80 mg Ge absorber into a 1.6 mg doped Ge thermistor via a superconducting Al film. We report on pulse height spectra obtained at 320 mK by scanning a {sup 241}Am alpha source along the device, and show that up to 20% of the energy deposited in the Ge absorber by a 5.5 MeV alpha particle interaction can be collected into a thermistor via quasiparticle trapping. We show that this device is sensitive to the position of an alpha particle interaction in the Ge absorber for interaction distances of up to 5 mm from a quasiparticle trap.
1995-05-15
X-ray dose enhancement effects
International Nuclear Information System (INIS)
A brief description of the physical process of dose enhancement effects produced by X-ray radiation on materials is given, with emphasis on the influence on electronic devices. The damages caused by X-ray radiation dose enhancement is more serious than that of #gamma#-ray with higher energy.
Stochastic risk estimate for barium radiological examinations in Malaga (Spain)
International Nuclear Information System (INIS)
The aim of this research work has been the estimation of the stochastic risk for five barium examinations. The sample was the population attending the Radiological Service of the 'Nuestra Senora de la Victoria' University Hospital, who had been treated with some barium examinations, set in five different groups: oesophagus tract, oesophagus-gastric-duodenal tract, intestinal tract, enteroclysis and double enema. To estimate the stochastic risk, it is necessary to know the organ dose. This can be calculated from the dose-area product which allows us to determine the effective dose using software. The dose-area product is the most suitable quantity to measure in these types of examination. We have evaluated the contribution that each procedure provides to the genetically significant dose, somatically significant dose, collective effective ...
2000-01-01
UK PubMed Central (United Kingdom)
Voxel-based prescriptions of deliberately non-uniform dose distributions based on molecular imaging, so-called dose painting or theragnostic radiation therapy, require specification of a transformation...Full Text Available
2009-03-21
On the accuracy and effectiveness of dose reconstruction for tomotherapy
International Nuclear Information System (INIS)
Dose reconstruction is a process that re-creates the treatment-time dose deposited in a patient provided there is knowledge of the delivered energy fluence and the patient's anatomy at the time of treatment. A method for reconstructing dose is presented. The process starts with delivery verification, in which the incident energy fluence from a treatment is computed using the exit detector signal and a transfer matrix to convert the detector signal to energy fluence. With the verified energy fluence and a CT image of the patient in the treatment position, the treatment-time dose distribution is computed using any model-based algorithm such as convolution/superposition or Monte Carlo. The accuracy of dose reconstruction and the ability of the process to reveal delivery errors are presented. Regarding accuracy, a reconstructed dose distribution was compared with a ...
2001-04-01
Induction of bladder cancer in rats by fractionated intravesicular doses of N-methyl-N-nitrosourea.
UK PubMed Central (United Kingdom)
Experiments were conducted to determine the dose response of rat bladder urothelium to a range of different single and fractionated intravesicular doses of the carcinogen, N-methyl-N-nitrosourea (MNU)....Full Text Available
1982-03-01
International Nuclear Information System (INIS)
Objective: To investigate the relationship between exposure dose and image quality for a direct digital radiography system and to determine the optimum exposure parameters for pelvic examination. Methods: A contrast-detail phantom CDRAD2.0 was exposed to different doses and the IQF of phantom images were calculated. The optimum exposure parameters were determined by ANOVA and SNK analysis. The image of an anthropomorphic phantom taken with optimized exposure parameters was verified using CEC image criteria. Results: The IQF of the images of CDRAD2.0 phantom was significantly different for different doses, as the exposure dose was greater than 0.61 mGy. The IQFs have no difference for different dose groups. The image quality between this optimized exposure dose and conventional exposure dose not was significantly different. Conclusion: The ...
2005-10-01
Effects of small doses of ionizing radiation on human health
Energy Technology Data Exchange (ETDEWEB)
The risks to human health from small doses of ionizing radiation raise questions which remain largely unanswered. This paper begins by explaining the historical background to this subject; it goes on to discuss recent developments and concludes with a personal view of the dose-reponse relationship. (author).
1997-12-01
Effects of small doses of ionizing radiation on human health
International Nuclear Information System (INIS)
The risks to human health from small doses of ionizing radiation raise questions which remain largely unanswered. This paper begins by explaining the historical background to this subject; it goes on to discuss recent developments and concludes with a personal view of the dose-reponse relationship. (author).
1997-01-01
UK PubMed Central (United Kingdom)
Purpose:To investigate the clinical usage of dose verification of Helical Tomotherapy plans by using 2D-array ion chambers, and to develop an efficient way to validate the dose delivered...Full Text Available
A two-stage sequential linear programming approach to IMRT dose optimization
UK PubMed Central (United Kingdom)
The conventional IMRT planning process involves two stages in which the first stage consists of fast but approximate idealized pencil beam dose calculations and dose optimization and the second...Full Text Available
2010-02-07
The EPA (Environmental Protection Agency) low-level waste standard-a status report
Energy Technology Data Exchange (ETDEWEB)
The Environmental Protection Agency (EPA) is developing generally applicable environmental standards for land disposal of Atomic Energy Act (AEA) low-level radioactive wastes (LLW) and certain naturally occurring and accelerator-produced radioactive material (NARM) wastes. It is EPA's intention that the LLW standards will protect public health and the environment. The LLW standards would cover disposal of all AEA materials not controlled by other EPA standards and some natural radioactive materials. Coverage of federal waste is significant, because the federal government generates and disposes of >40% of all LLW nationwide, and a uniform standard for all LLW disposal is both a desirable and an achievable goal. Publication of a proposed LLW standard is planned in 1988, and a final standard a year later. This ...
1988-01-01
The use of nitrogen isotopes in research on sheep nutrition
International Nuclear Information System (INIS)
Using nitrogen-13 initial measurements have been made of rumen ammonia-nitrogen pool size and turnover, and rate of incorporation of ammonia into microbial protein. It is also feasible to measure the rate of incorporation of absorbed ammonia into urea and the appearance of label in saliva.
1985-08-26
The Neutron Radiography Reactor (NRAD)
The Neutron Radiography Reactor (NRAD) operated by Argonne National Laboratory is described in this paper. NRAD was designed to allow radiography of highly absorbing reactor fuel assemblies in the vertical position on the routine basis. 7 figs.
1990-01-01
The Chemical Reactions of Sulfur in the Citrate Process for Flue Gas Desulfurization.
The Bureau of Mines performed chemical research to elaborate details of sulfur chemistry pertaining to the citrate flue gas desulfurization process in which sulfur dioxide (SO2), absorbed (as bisulfite ion) in a buffered sodium citrate solution, is reduce...
1981-01-01
The Atmospheric Trace ... - NASA Langley Science Directorate
Trace gas molecules absorb specific wavelengths of incoming solar ... These data(with information collected from similar experiments carried on balloons, rockets, ... The ATMOS sensor instrumentis a state-of-the-art version of a 19th century ...
Remote disassembly of the absorber open-test assembly at the FFTF/IEM cell
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF) interim examination and maintenance (IEM) cell is used for the remote disassembly of irradiated fuel and material experiments. The absorber open-test assembly (AOTA) is a 12-m (40-ft)-long instrumented absorber (control-rod-material) test assembly. Its primary purpose is to characterize the FFTF control-rod-material reaction rate during reactor operation. Instrumentation allowed temperature and pressure measurements at various locations in several absorber pins during reactor operation. After residing several months in the reactor, the assembly was transferred to the IEM cell by the closed-loop ex-vessel machine (CLEM) for separation of the irradiated portion of the experiment from the instrument stalk. After separation, the 3.6-m (12-ft)-long assembly was processed through the sodium removal system and shipped off-site for examination. This success allowed the timely completion of a major ...
1990-11-11
Energy Technology Data Exchange (ETDEWEB)
The A(..pi../sup +/,/sup 3/He)B reaction near threshold is studied in a model where the pion is absorbed by an /sup 4/He constituent of the target nucleus. The predictions of this model using harmonic oscillator cluster wave functions agree semi-quantitatively with the experimental data on the inverse reaction.
1982-03-10
Incorporate the latest FGD trends into mist-eliminator design. [Flue gas desulfurization
Mist eliminators for flue gas desulphurisation units remove liquid droplets entrained in the flue gas leaving the SO/sub 2/-absorber vessels. The commercial designs currently available are described.
1984-03-01
Gun Barrel Vibration Absorber to Increase Accuracy
Page 1. Page 2. Page 3. Page 4. Page 5. Page 6. Page 7. Page 8. Page 9. Page 10. Page 11. Page 12. Page 13. Page 14. Page 15. Page 16. Page ...
2002-02-01
GaAs Blocked-Impurity-Band Detectors for Far-Infrared Astronomy
Energy Technology Data Exchange (ETDEWEB)
High-purity and doped GaAs films have been grown by Liquid-phase epitaxy (LPE) for development of a blocked impurity band (BIB) detector for far-infrared radiation. The film growth process developed has resulted in the capability to grow GaAs with a net active impurity concentration below 1 x 10{sup 13} cm{sup -3}, ideal for the blocking layer of the BIB detector. The growth of n-type LPE GaAs films with donor concentrations below the metal-insulator transition, as required for the absorbing layer of a BIB detector, has been achieved. The control of the donor concentration, however, was found to be insufficient for detector production. The growth by LPE of a high-purity film onto a commercially grown vapor-phase epitaxial (VPE) n-type GaAs doped absorbing layer resulted in a BIB device that showed a significant reduction in the low-temperature dark current compared to the absorbing layer only. Extended optical response was ...
2004-12-21
First Measurements of the Inclined Boron Layer Thermal-Neutron Detector for Reflectometry
Energy Technology Data Exchange (ETDEWEB)
A prototype detector based on the inclined absorber layer principle is introduced. For the Liquids Reflectometer at the Spallation Neutron Source, it is shown to be a significant improvement over its current detector, which imposes an instantaneous count rate limitation of 50 kcps.
2008-10-01
Design and Validation of a Gun Barrel Vibration Absorber.
Page 1. Page 2. Page 3. Page 4. Page 5. Page 6. Page 7. Page 8. Page 9. Page 10. Page 11. Page 12. Page 13. Page 14. Page 15. Page 16. Page ...
1997-05-01
Current state of methodology on hemoglobin oximetry in tissues.
Photon migration provides sensitive tissue oximetry in which the optical pathlength is known. Phase array gives the precise location of a subnanomolar amount of hidden absorber in highly scattering medium. PMID:8079713
1994-01-01
Carbon dioxide, climate and the sea
Energy Technology Data Exchange (ETDEWEB)
Only half of the carbon dioxide produced by burning fossil fuels stays in the atmosphere. It is thought that the oceans absorb the rest. To understand the world's climate it is necessary to know how the atmosphere, ocean and biosphere interact.
1985-11-21
Carbon dioxide absorption methanol process
Energy Technology Data Exchange (ETDEWEB)
A process is described for removing carbon dioxide from a feed stream of natural gas, having at least methane, ethane and heavier hydrocarbon, comprising: separating the feed stream in a first separator to form a first stream, having substantially all of the propane and heavier hydrocarbons and carbon dioxide and ethane, and a second stream, having methane, carbon dioxide and ethane; mixing the second stream with a polar compound to form a third stream; separating the vapor and liquid of the third stream in the bottom portion of an absorber; absorbing carbon dioxide and ethane from the separated vapor of Step C in a lean portion of the polar compound in the absorber, the absorber carbon dioxide and ethane forming a fourth stream; separating the ethane from the polar compound and carbon dioxide in a separator; separating the first stream in a third separator to separate the propane and heavier ...
1987-06-23
Black holes as detectors of tachyons
International Nuclear Information System (INIS)
Tachyons fired into and absorbed by rotating black holes can violate the second and third laws of black hole physics. It is suggested that apparent break-downs of these laws in astrophysical black holes can indicate the existence of cosmic tachyons. (author).
Adaptive Gun Barrel Vibration Absorber.
Gun barrel vibrations lead to dispersion in the shot patterns. Thus, reducing these vibrations should lead to increased accuracy. Since the muzzle is the anti-node for all vibration modes and its vibrations have the greatest effect on shot dispersion, it ...
2002-01-01
Absorption of tachyons in extended relativity an answer to Basano
International Nuclear Information System (INIS)
It is answered to a previous letter by Basano, and shown that the difficulties met by that author within ''Extended relativity'' do not exist, but are due to the erroneous assumption that a certain condition for tachyons to be absorbed by a macro-object is sufficient (whilst it is only a necessary one).
UK PubMed Central (United Kingdom)
INTRODUCTIONCutiplast (absorbent perforated dressing with adhesive border; Smith & Nephew) is commonly used following orthopaedic operation, but complications of its use...Full Text Available
2006-01-01
Organ doses and integral doses in X-ray diagnosis of the chest and of the head
International Nuclear Information System (INIS)
Organ and tissue doses and integral doses in patients due to diagnostic x-ray examinations of the chest and of the head will be presented. These data have been obtained by measuring the dose distributions in man phantoms by LiF-dosimetry. The data will be compared with data obtained by Monte-Carlo calculations. To obtain average organ doses for a special type of examination for the population or for a specified subpopulation in the variation of the exposure, data due to the different techniques used by the different radiologists has to be known. Such data will be presented. The results of the investigation will be discussed in connection with the concept of the 'somatic significant.
1977-04-01
NEUTRON-ABSORBING BRICKS MADE FROM CaB$sup 6$
nsive neutron-absorbing bricks from commercially available CaB/sub 6/ powder. The bricks are 2 x 3 x 5 in., and are strong enough to withstand normal handling. They last indefinitely; the ones described are now 7 years old, used and stored under normal room temperatures and humidities. The procedure is to make a thick, dry mud with the powder and water, followed by compression in a mold at pressures of about 1 ton/in./sup 2/ or more. The bricks are then baked for 2 hours or longer at a temperature of about 750 deg C. (auth)
1960-05-01
Modeling and Experimental Study of Carbon Dioxide Absorption in a Membrane Contactor
Energy Technology Data Exchange (ETDEWEB)
This dissertation deals with membrane gas absorption in the application of CO{sub 2} removal by aqueous alkanolamines, using microporous PTFE hollow fiber membranes. A new lab-scale apparatus was constructed and an extensive experimental study executed to determine the performance of the membrane gas absorber, with aqueous solutions of monoethanolamine (MEA) and methyldiethanolamine (MDEA) as absorbents. The important operation parameters CO{sub 2} partial pressure, gas velocity, liquid velocity, temperature and liquid CO{sub 2} loading were systematically varied within the range typically experienced in a process for exhaust gas CO{sub 2}-removal
2003-03-15
Analysis of the thermal performance of dynamic solar systems
Energy Technology Data Exchange (ETDEWEB)
This article proposes a model for estimating the effect of the overall thermal resistance of the absorber and the coolant on a solar thermal energy system utilizing advanced heat transfer mediums. Two equations can be used to model a dynamic system: one for the maximum conversion efficiency and one to specify the constraint that, in quasi-steady state, the net energy collected must be transferred to the coolant. These two equations define a constrained optimization problem in two variables, the fluid and the absorber temperatures. The results present interesting implications for liquid metal, direct absorption, and solar evaporating systems.
1996-03-01
On the Impact of Longitudinal Breathing Motion Randomness for Tomotherapy Delivery
UK PubMed Central (United Kingdom)
The purpose of this study is to explain the unplanned longitudinal dose modulations that appear in helical tomotherapy (HT) dose distributions in the presence of irregular patient breathing....Full Text Available
2008-09-21
Dose verification using a pelvic phantom in high dose rate (HDR) brachytherapy
Energy Technology Data Exchange (ETDEWEB)
High dose rate (HDR) brachytherapy for treating a cervix carcinoma has become popular, because it eliminates many of the problems associated with conventional brachytherapy. In order to improve the clinical effectiveness with HDR brachytherapy, a dose calculation algorithm, optimization procedures, and image registrations need to be verified by comparing the dose distributions from a planning computer and those from a humanoid phantom. In this study, the humanoid phantom was fabricated in order to verify the absolute doses and the relative dose distributions. The measured doses from the humanoid phantom were then compared with the treatment planning system for the dose verification. The humanoid phantom needs to be designed such that the dose distributions can be quantitatively evaluated thermoluminescent dosimeter (TLD) ...
2003-07-01
A doubly Q-switched laser with both an acousto-optic (AO) modulator and a GaAs saturable absorber can obtain a more symmetric and shorter pulse with high pulse peak power, which has been experimentally proved. The key parameters of an optimally coupled doubly Q-switched laser with both an AO modulator and a GaAs saturable absorber are determined, and a group of general curves are generated for what we believe is the first time, when the single-photon absorption (SPA) and two-photon absorption (TPA) processes of GaAs are combined, and the Gaussian spatial distributions of the intracavity photon density and the initial population-inversion density as well as the influence of the AO Q-switch are considered. These key parameters include the optimal normalized coupling parameter, the optimal normalized GaAs saturable absorber parameters, and the normalized parameters of the AO Q-switch, which can maximize the output energy. ...
2007-08-20
International Nuclear Information System (INIS)
The aim of the study is to prepare ionic exchangers using the polymerization of unsaturated polyster with monomeric styrene units in a ratio of 60%: 40% respectively. The type of method involved in this preparation, is called An Emulsion Polymerization. Such type of polymerization was carried out by two techniques: chemical and irradiation techniques. The first techniques requires the formation of free radical monomers by use of methyl Ethy Ketone Peroxide capable of decomposing into free radicals upon heating, while the other technique involves the use of gamma rays (using Co-60 source) capable of activating monomers towards free radical formations. A number of very effective chemical parameters and physical factors were used and investigated throughout the reactions such as: dispersant matrix, viscosity, rate of mixing, and irradiation dose. Besides, the study has included the study of the rate of Resin Beads Swelling which is thought to be another important part ...
3087-01-01
Vector Boson Scattering in the Standard Model an Overview of Formulae
Tree-level scattering amplitudes of longitudinally polarized electroweak vector bosons in the Standard Model are calculated using Mathematica package Feyncalc. The modifications of low-energy theorems for longitudinally polarized W and Z in the Standard Model are discussed.
1997-01-01
System 80+{trademark} standard design: CESSAR design certification. Volume 15: Amendment I
Energy Technology Data Exchange (ETDEWEB)
This report has been prepared in support of the industry effort to standardize nuclear plant designs. These documents describe the Combustion Engineering, Inc. System 80+{trademark} Standard Design.
1990-12-21
System 80+trademark standard design: CESSAR design certification
International Nuclear Information System (INIS)
This report has been prepared in support of the industry effort to standardize nuclear plant designs. These documents describe the Combustion Engineering, Inc. System 80+trademark Standard Design.
Clinical pathology accreditation: standards for the medical laboratory
UK PubMed Central (United Kingdom)
This article describes a new set of revised standards for the medical laboratory, which have been produced by Clinical Pathology Accreditation (UK) Ltd (CPA). The original standards have been in use...Full Text Available
2002-10-01
Benzene Enabling Document for Standards on Benzene Transfer and Waste Operations.
On February 27, 1990, standards for Benzene were promulgated for benzene transfer and benzene waste operations. The benzene enabling document summarizes these standards. The basic purpose of the document is to assist the EPA regional enforcement personnel...
1990-01-01
Abnormalities in the microsomal oxidases of the WHO standard reference strain of Musca domestica*
UK PubMed Central (United Kingdom)
Observations made during biochemical and toxicological studies of the housefly, in which the WHO standard reference (SR) strain was used as a standard, indicated that this strain differs from other...Full Text Available
1975-01-01
...2010-10-01 false Standards for health information technology to protect electronic health information...DEPARTMENT OF HEALTH AND HUMAN SERVICES HEALTH INFORMATION TECHNOLOGY HEALTH INFORMATION TECHNOLOGY STANDARDS, IMPLEMENTATION...
2010-10-01
International Nuclear Information System (INIS)
Using standards on phenol-formaldehyde resin base for assaying-activation analysis of geological specimens for gold and silver has bee the advantage of uniformly distributing Au and Ag in spesimens and possible preparing tablets of practically any form or size. The validity and accuracy of these standards have been studied for the cases of short irradiation. Conventional point standards were used as reference standards. The experiments carried out have shown that tablet resol standards are suitable for a mass assaying-activation analysis for gold and silver at practically any concentrations.
Energy Technology Data Exchange (ETDEWEB)
In order to realize improve of reliability and economy by duplicate production, rapid supply of repair parts from standardized storage, such were expected as to have continuous order of standardized plant, to ignore site condition, to avoid expansion of regulatory requirement. Standardization program was planned to limitedly promote standardization of safety-related design concept, major specification and basic system composition of reactor and primary systems. The area of standardization had been tried to expand to BOP such as general arrangement and rad-waste system.
1985-07-01
Development of an analysis rule of diagnosis error for standard method of human reliability analysis
International Nuclear Information System (INIS)
This paper presents the status of development of Korea standard method for Human Reliability Analysis (HRA), and proposed a standard procedure and rules for the evaluation of diagnosis error probability. The quality of KSNP HRA was evaluated using the requirement of ASME PRA standard guideline, and the design requirement for the standard HRA method was defined. Analysis procedure and rules, developed so far, to analyze diagnosis error probability was suggested as a part of the standard method. And also a study of comprehensive application was performed to evaluate the suitability of the proposed rules.
2003-10-01
The Effects of Long Term Storage on Special Purpose Lead ...
... Special Purpse Lead Azide Lot #I3A-4-62 ... Standard X-ray techniques are not sufficiently sensitive ... the National Bureau of Standards, and examined ...
1972-10-01
The Economic Strategy for German Unification
... PERSONAL AUTHOR(S) ROY A. BROOKS, LTC i3a. ... gave the impression of an immediate increase in the standard ... high rate by German standards. ...
1993-02-19
The Development of a Dental Diagnostic Terminology
UK PubMed Central (United Kingdom)
There is no commonly accepted standardized terminology for oral diagnoses. The purpose of this article is to report the development of a standardized dental diagnostic terminology by a work...Full Text Available
2011-01-01
STUDY OF METEOR WIND MEASUREMENT TECHNIQUES. ...
... of a secondary standard (VCO) locally available. ... phase of the local secondary standards to the 10-min average of the phase of ... I3a - - \\.-e-~--. ...
1970-02-01
Energy Technology Data Exchange (ETDEWEB)
The Seabed Disposal Project (SDP) was evaluating the technical feasibility of high-level nuclear waste disposal in deep ocean sediments. Working standards were needed for risk assessments, evaluation of alternative designs, sensitivity studies, and conceptual design guidelines. This report completes a three part program to develop radiological standards for the feasibility phase of the SDP. The characteristics of subseabed disposal and how they affect the selection of standards are discussed. General radiological protection standards are reviewed, along with some new methods, and a systematic approach to developing standards is presented. The selected interim radiological standards for the SDP and the reasons for their selection are given. These standards have no legal or regulatory status and will be replaced or modified by regulatory ...
1997-06-01
Impacts of Renewable Fuel and Electricity Standards on State Economies (Poster)
Energy Technology Data Exchange (ETDEWEB)
This poster, submitted for the CU Energy Initiative/NREL Symposium on October 3, discusses the impacts of renewable fuel and electricity standards on state economies.
2006-10-03
Energy Technology Data Exchange (ETDEWEB)
This final report for the Swiss Federal Office of Energy (SFOE) examines a project that aimed to define standard solutions for use in buildings built to meet Minergie low energy consumption standards. These standard solutions are to provide a way of meeting Minergie standards in an easy way and thus further the use of the standard and also assure quality at the same time. The report describes how the solutions were developed on the basis of a selection of existing Minergie buildings. For various combinations of heating systems - wood, wood/solar, heat pumps (brine-water and air-water), gas/solar and oil/solar - the appropriate U-values for various building elements are listed. The resulting Minergie forms and guides are listed.
2003-07-01
An Evaluation of a Technique for Using the Combat Training ...
... proficiency, most Army personnel must shoot to the same standards required of ... Wild- flecken was to provide this standard range, but its scores ... I3a I] ...
1979-05-01
A PC-Based Imaging System for the Naval Postgraduate ...
... 1 I3a TYPE OF REPORT 1 3b TIME COVERED ... Measured by this standard the system provides good results; it ... did not fully meet all the standards or ...
1989-09-01
50 (Fifty) Years of Research on Man in Flight
... i3a. ... This pioneering research established the new Air Force standard for future ... Echols ,.stablished new standards for high- altitude long-range flight ...
1985-06-01
Energy Technology Data Exchange (ETDEWEB)
To evaluate the usefulness of radiation therapy alternative to surgery for clinical N0-N1 non-small cell lung cancer (NSCLC). From 1976 through 1989, 116 patients with NSCLC without mediastinal involvement were treated with definitive radiation therapy alone at Gunma University Hospital. All patients were treated with once-daily standard fractionation using 10 MV X-rays. The total dose ranged from 60 Gy to 80 Gy. The actuarial 2- and 5-year survival rates of the entire group were 43% and 20%, respectively with a median survival time of 19 months. The survival of 76 patients with stage T2 tumors was significantly better than that of 28 patients with T3 tumors (mean survival time 21 versus 15.5 months; p<0.05). Sixty-two patients with tumors less than 5 cm in diameter had a 2-year progression rate of 20%, in comparison with 39% of 54 patients with tumors greater than 5 cm. The difference of survivals for these 2 groups was statistically ...
1996-09-01
Total dose hardening of SIMOX buried oxides for fully depleted devices in rad-tolerant applications
International Nuclear Information System (INIS)
A total dose hardening treatment is applied to SIMOX buried oxides. Total ionizing dose radiation testing is performed on fully-depleted transistors fabricated on both hardened and non-hardened substrates. At 200 krads x-ray dose, the front gate shift is reduced from -0.7 to -0.2 V for FETs built on the hardened wafers.
1996-07-15
Survey of radiation doses to patients from the diagnostic use of X-rays
International Nuclear Information System (INIS)
The National Radiological Protection Board is to carry out a survey of doses received by patients from the diagnostic use of X-rays, beginning in June 1977, and carried out at over 100 National Health Service hospitals. Details are given of the reasons for carrying out the survey and the survey objectives. The survey working methods are discussed, together with methods of calculation of the genetically significant dose. The radiation doses will be measured by a thermoluminescent dosimeter developed specially for the survey. (U.K.).
1977-06-01
International Nuclear Information System (INIS)
... radiation effects human populations low dose irradiation neoplasms radiation
1980-01-01
International Nuclear Information System (INIS)
... organizations irradiation radiation doses radiation effects RADIATIONS.
1982-01-01
Software means of dose consumption planning
International Nuclear Information System (INIS)
Russian 2009 p. 118 Ukraine Mazilov, AV Stadnik, IA NSC 'Kharkiv
2009-02-23
Infrared stimulated luminescence-decay shape from NaCl as a function of radiation doses
Energy Technology Data Exchange (ETDEWEB)
Dose-dependent behavior of the infrared stimulated luminescence (IRSL) decay from NaCl has been studied experimentally using only one aliquot irradiated with a range of 2-200 Gy {beta}-radiation doses. It was observed that the maximum IRSL intensity has not changed by an increase in dose though the total intensity increased as expected. Considering the possible implications of our findings for dosimeter, the results were compared with the other studies and discussed.
2007-11-15
Influencing factors on ESR dose assessment in irradiated chicken legs
Energy Technology Data Exchange (ETDEWEB)
Electron spin resonance (ESR) dosimetry of irradiated chicken legs is based on the additive dose or the calibration curve methods. In both cases the practical assumption is made that the behaviour of the chicken bone does not depend on factors such as temperature during irradiation, storage conditions and dose rate. So the aim of the present work was to investigate to what extent the above mentioned factors could influence the post-irradiation dose assessment using the ESR technique. (author).
1996-12-31
International Nuclear Information System (INIS)
... pathological changes patients radiation protection radiotherapy diseases
1982-10-25
Energy Technology Data Exchange (ETDEWEB)
The risks from radiation exposure during radiological diagnosis has usually been estimated in relation to genetic changes. Relevant information has been expressed as the genetically significant dose. In this paper we attempt to produce an analogous measure for evaluating the somatic risk in the form of a somatically significant dose index for radiological and CT examinations. It is shown that, for both types of examination, the two risk factors may be entirely different.
1980-10-01
International Nuclear Information System (INIS)
The risks from radiation exposure during radiological diagnosis has usually been estimated in relation to genetic changes. Relevant information has been expressed as the genetically significant dose. In this paper we attempt to produce an analogous measure for evaluating the somatic risk in the form of a somatically significant dose index for radiological and CT examinations. It is shown that, for both types of examination, the two risk factors may be entirely different. (orig.).
1980-01-01
Effective dose equivalent in nuclear medicine investigations
International Nuclear Information System (INIS)
... radiation hazards hazards health hazards MEDICINE. SOMATICALLY
1984-05-07
Energy Technology Data Exchange (ETDEWEB)
Collective dose equivalent and population dose from occupational exposures in Japan, 1988 were estimated on the basis of a nationwide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 0.21 million workers except for the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the official report of the Japan Nuclear Safety Commission. The total number of workers including nuclear power stations was estimated to be about 0.26 million. Radiation works were subdivided as follows: medical works including dental; non-atomic energy industry; research and education; atomic energy industry and nuclear power station. For the determination of effective dose equivalent and population dose, organ or tissue doses were measured with a phantom experiment. ...
1993-05-01
International Nuclear Information System (INIS)
Collective dose equivalent and population dose from occupational exposures in Japan, 1988 were estimated on the basis of a nationwide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 0.21 million workers except for the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the official report of the Japan Nuclear Safety Commission. The total number of workers including nuclear power stations was estimated to be about 0.26 million. Radiation works were subdivided as follows: medical works including dental; non-atomic energy industry; research and education; atomic energy industry and nuclear power station. For the determination of effective dose equivalent and population dose, organ or tissue doses were measured with a phantom experiment. ...
1993-01-01
Bulgarian population exposure resulting from diagnostic nuclear-medicine applications
International Nuclear Information System (INIS)
... populations radiation doses RADIOACTIVE MATERIALS. SOMATICALLY
1980-10-26
Energy Technology Data Exchange (ETDEWEB)
In an epidemiological study of the somatic late effects risk following incorporation of a short lived {alpha}-emitter, 1473 ankylosing spondylitis patients treated with repeated intravenous injections of {sup 224}Ra in the years 1948 - 75, have been observed in the GSF. The usual therapeutic plan consisted of a total of 10 - 12 injections of 1.036 MBq (28 {mu}Ci) of {sup 224}Ra each, given at weekly intervals; this would result in an cumulative {alpha}-dose of 0.56 - 0.67 Gy to the marrow-free skeleton of a 70-kg-man (standard man). These patients have been followed together with a control group of ankylosing spondylitis patients not treated with radioactive drugs and/or X-rays. Until May 1993 (mean follow-up time 19.9 yr), 595 patients of the exposure group and 722 patients of the control group have died, causes of death have been ascertained for 578, resp. 668 patients. Among others we observed in the exposure group 10 cases of leukaemia (vs. ...
1993-12-31
Energy Technology Data Exchange (ETDEWEB)
This report describes a comparison result of technical standards applied to instrumentation and control systems for nuclear power plants between in Korea and in Russia. Russia also has a state-run organization authorized to conduct approval, cancellation, and audit in use of nuclear facility or equipment. The Russian standards for nuclear instrumentation and control equipment are analogous with the Korean ones in the aspect of basic concepts and principles. However, there are some differences in document structure, design requirements, qualification test items, depth of contents between two standard systems. The biggest deviation exists in the standard documents for seismic qualification and electromagnetic interference qualification. Korean seismic qualification standard utilizing US approach, defines testing and qualification methods specifically and clearly. Russian ...
2005-04-15
Effect of dose on lead retention and distribution in suckling and adult female mice
Energy Technology Data Exchange (ETDEWEB)
Single doses of lead (trace to 445 mg/kg) were administered per os to suckling and adult mice. Both groups exhibited dose-independent lead retention when doses of 4 to 445 mg/kg were administered. However, developmental differences in the fraction of initial dose (FID) retained were evident for all doses administered. A much larger FID was retained in both age groups following administration of carrier-free /sup 203/Pb. The results are consistent with a mechanism of gastrointestinal lead absorption comprising two or more processes. Developmental differences were also observed in organ lead concentration relative to whole body concentration for kidneys, skull and brain 6 days following lead administration. Lead retentions (relative to whole body retention) in brain and in bone were linearly related to dose of lead administered in both suckling and adult age ...
1980-01-01
Donut-shaped high-dose configuration for proton beam radiation therapy
Energy Technology Data Exchange (ETDEWEB)
Background: the authors report on the conception and first clinical application of a donut-shaped high-dose configuration for proton therapy (PT). This approach allows one to intensify target volume dose coverage for targets encompassing a critical, dose-limiting structure - like here, the cauda equina -, whilst delivering minimal dose to other healthy structures surrounding the target, thereby reducing the integral dose. Methods and results: intensity-modulated PT methods (IMPT) for spot scanning were applied to create and deliver a donut-shaped high-dose configuration with protons, allowing treating > 75% of the target with at least 95% of the prescribed dose of 72.8 CGE, whilst restricting dose to the cauda equina to 60-65 CGE. Integral dose was lower by a factor of 3.3 as compared to ...
2005-01-01
Donut-shaped high-dose configuration for proton beam radiation therapy
International Nuclear Information System (INIS)
Background: the authors report on the conception and first clinical application of a donut-shaped high-dose configuration for proton therapy (PT). This approach allows one to intensify target volume dose coverage for targets encompassing a critical, dose-limiting structure - like here, the cauda equina -, whilst delivering minimal dose to other healthy structures surrounding the target, thereby reducing the integral dose. Methods and results: intensity-modulated PT methods (IMPT) for spot scanning were applied to create and deliver a donut-shaped high-dose configuration with protons, allowing treating > 75% of the target with at least 95% of the prescribed dose of 72.8 CGE, whilst restricting dose to the cauda equina to 60-65 CGE. Integral dose was lower by a factor of 3.3 as compared to ...
2005-01-01
An evaluation of low-dose single-slice helical CT in pulmonary CT scan
International Nuclear Information System (INIS)
Objective: To investigate the feasibility of low-dose single-slice helical CT in pulmonary CT scan and evaluate the clinical application. Methods: Thirteen cases were selected out of 132 cases, in which low-dose (50mAs) single-slice helical CT scan of chest was performed. This set of cases included 7 cases of multiple metastatic nodules; 3 of solitary pulmonary, nodule; and 3 of pulmonary patchy lesions. Regular dose (170mAs) CT scan was also performed on all those patients. The regular dose and low dose CT scan were compared on sensitivity of detecting the lesions; the performance in demonstrating the details of the abnormalities; and the capability of revealing the segmental bronchi as well. Results: The same number and size of the pulmonary nodules were revealed with scan modalities loaded with different doses. No significant difference in demonstrating the ...
2006-04-01
Radiation risk in diagnostic radiology
International Nuclear Information System (INIS)
An attempt was made to quantify the radiation risk of diagnostic radiology. After a general introduction of terms as radiation damage, radiation risk and effective dose equivalent, based on publications of the ICRP, somatic dose indexes were computed for several radiologic investigations, that comprise organ doses committed to red bone marrow, lung, female breast and thyroid with and without considering the rest of the body. The dose for the rest of the body was assumed to be equal to the dose received by the red bone marrow, that is also distributed over the whole body. Neglecting the exposure of the rest of the body resulted in an insignificant increase in the estimated somatic risk, with its experimental determination not being necessary. (author).
1984-01-01
International Nuclear Information System (INIS)
Full text: An adaptive response is a decreased biological effect induced by a priming radiation dose given prior to a challenge dose. Adaptive responses contradict the linear-nothreshold model of risk estimation. The pKZ1 mouse chromosomal inversion assay is an extremely sensitive assay for studying the mutagenic effect of low dose radiation. A non-linear dose response for chromosomal inversion has been observed in pKZ1 spleen and prostate after a single whole body irradiation with doses between 1?Gy and 10mGy. Doses between 5-10?Gy resulted in an induction in inversions and doses between 1-10mGy resulted in a reduction below endogenous inversion frequency. These results suggest that doses in the 1-10 mGy range cause host responses which overcompensate by not only preventing inversions that would normally occur as a ...
2006-04-01
Valuing future citizens' values regarding risk
Energy Technology Data Exchange (ETDEWEB)
Valuing present citizen's values regarding the risks they face is an important aspect of risk assessment and risk acceptability. Conferences like VALDOR are held for this reason. Governments like Sweden have national referendums on various risk-prone enterprises. The results of these referendums can determine the future of these programs. In the United States, when guidelines are set for determining acceptable levels of risk, the relevant federal agencies are often required to provide a comment period regarding proposed guidelines in order to ascertain the judgments, including the weights place on certain values, of individual members of society as well as stakeholder groups. After the comment period ends, the agency decides on the acceptable level of risk, taking into account the comments from present citizens. Do we also have a duty to value the not-yet-existing values of future citizens, especially if the risks created by the activities of present citizens extend into the ...
2006-09-15
Validation of the Canadian atmospheric dispersion model for small exclusion area boundaries
International Nuclear Information System (INIS)
AECL is undertaking the validation of ADDAM, an atmospheric dispersion and dose code based on the Canadian Standards Association model CSA N288.2. The key component of the validation program involves the comparison of air concentrations predicted by the model with measured values. Measurements are available from field studies at two Canadian reactor sites and from a wind tunnel study of the CANDU site at Wol song, Korea. The measurements were obtained close enough to the release points to test the model for exclusion area boundaries as small as 500 m. Model predictions were higher than the observations almost 75 percent of the time and the magnitude of the over predictions was typically much larger than the magnitude of the under predictions. The effect of the topography at the Wol song site was limited to small changes in plume trajectory due to channeling in valleys and a small reduction in the lateral spread of the plume. The terrain did not ...
1999-11-04
Energy Technology Data Exchange (ETDEWEB)
The Institute of Energetic and Nuclear Research - IPEN is a research and development institution, located in a densely populated area, in the city of Sao Paulo. The nuclear fuel cycle was developed from the Yellow Cake to the enrichment and reconversion at IPEN. After this phase, all the technology was transferred to private enterprises and to the Brazilian Navy (CTM/SP). Some plants of the fuel cycle were at semi-industrial level, with a production over 20 kg/h. As a research institute, IPEN accomplished its function of the fuel cycle, developing and transferring technology. With the necessity of space for the implementation of new projects, the uranium hexafluoride (UF{sub 6}) production plant was chosen, since it had been idle for many years and presented potential leaking risks, which could cause environmental aggression and serious accidents. This plant decommission required accurate planning, as this work had not been carried out in Brazil before, for this type of facility, and ...
2008-07-01
Open test assembly (OTA) shear demonstration testing work/test plan
Energy Technology Data Exchange (ETDEWEB)
This document describes the development testing phase associated with the OTA Shear activity and defines the controls to be in place throughout the testing. The purpose of the OTA Shear Program was to provide equipment that is needed for the processing of 40 foot long, sodium wetted, irradiated core components previously used in the FFTF reactor to monitor fuel and materials tests. There are currently 15 of these OTA test stalks located in the Test Assembly Conditioning Station (TACS) inerted vault. These need to be dispositioned for a shutdown mission to eliminate this highly activated, high dose inventory prior to turnover to the ERC since they must be handled by remote operations. These would also need to be dispositioned for a restart mission to free up the vault they currently reside in. The waste handling and cleaning equipment in the J33M Cell was designed and built for the handling of reactor components up to the standard 12 foot ...
1998-07-16
Nuclear medicine progress report for quarter ending March 31, 1985
Energy Technology Data Exchange (ETDEWEB)
Radioiodinated 15-(p-iodophenyl)-3,3-dimethylpentadecanoic acid (DMIPP) has been prepared as a new terminal iodophenyl-substituted fatty acid containing dimethyl-branching at the beta-position. Iodine-125-labeled DMIPP showed rapid, high myocardial uptake (min, mean % injected dose/g) in fasted rats (5, 4.67; 30, 5.06; 60, 4.79; 120, 4.37), and also exhibited high heart:blood ratios (min, ratio) 5, 3:1; 30, 12:1; 60, 12:1; 120, 13:1. These data demonstrate an unanticipated much longer myocardial residence time with DMIPP (+/sub 1/2/ 7-8 h) than observed with either the 3-monomethyl (BMIPP) analogue (+/sub 1/2/ 30-45 min) or the rapidly metabolized straight-chain (IPP) analogue (+/sub 1/2/ 10-15 min). The (/sup 123/I)DMIPP is thus an excellent candidate for clinical evaluation of regional fatty acid metabolism under conditions where the uptake of energy substrates can be assessed independent of regional blood delivery. Studies with the new activated carbon-based ...
1985-07-01
Monte Carlo simulation of electron cones used in electron beam therapy
International Nuclear Information System (INIS)
A Siemens Mevatron KV2 accelerator installed at the Royal Adelaide Hospital employs cylindrical solid-walled electron cones for some electron collimation. The cones being used at present result in treatment fields that do not always conform with the International Electrotechnical Commission (IEC) Standards (particularly at high energies). The aim of this project was to simulate the existing cones using Monte Carlo methods in order to evaluate potential cone modifications required to overcome the field irregularities. Simulations were performed using the EGS4 (Electron Gamma Shower version 4, distribution II) Monte Carlo code installed on a DEC Alpha workstation at the University of South Australia. To rigorously simulate the existing electron cones it was necessary to also simulate various components within the treatment head of the linear accelerator. Results of simulations for existing cones were found to be consistent with experimental data. (obtained from Royal ...
1998-09-01
Initiation of conformal radiotherapy with a multileaf-collimator - An approach to clinical routine
International Nuclear Information System (INIS)
The implementation of a three-dimensional conformal radiotherapy facility in the radiotherapy department of the Heinrich Heine University is described. Complex radiotherapy techniques with commercially available networked systems are introduced to improve clinical work. Over 18 month we have gained clinical experience with a PHILIPS Multileaf Collimator (MLC) mounted on a SL 25 linear accelerator. For a limited period the MLC was used as a conventional blocking device. The standard MLC-shapes are controlled with a stand-alone computer system. In addition, a three-dimensional treatment planning system (3-D-TPS / TMS-Radix, Helax AB) based on convolution/superposition algorithms was recently installed. Treatment optimization is achieved using static field arrangements with complete volumetric computerized tomographic patient data for 3-D-TPS. Conformal adaptation of the 95%-isodose to the Planning Target Volume (PTV, ICRU 50) results in MLC-field-shaping concerning ...
1995-10-01
Correlates between immunological parameters and protection against Bacillus anthracis infection in animals vaccinated with protective antigen (PA)-based vaccines could provide surrogate markers to evaluate the putative protective efficiency of immunization in humans. In previous studies we demonstrated that neutralizing antibody levels serve as correlates for protection in guinea pigs (S. Reuveny et al., Infect. Immun. 69:2888-2893, 2001; H. Marcus et al., Infect. Immun. 72:3471-3477, 2004). In this study we evaluated similar correlates for protection by active and passive immunization of New Zealand White rabbits. Full immunization and partial immunization were achieved by single and multiple injections of standard and diluted doses of a PA-based vaccine. Passive immunization was carried out by injection of immune sera from rabbits vaccinated with PA-based vaccine prior to challenge with B. anthracis spores. Immunized rabbits were challenged ...
2006-01-01
Environmental Biosciences Report for Year 3
Energy Technology Data Exchange (ETDEWEB)
In May 2002, the United States Department of Energy (DOE) signed Assistance Instrument Number DE-FC09-02CH11109 with the Medical University of South Carolina (MUSC) to support the Environmental Biosciences Program (EBP). This funding instrument replaces DOE Assistance Instrument Number DE-FC02-98CH10902. EBP is an integrated, multidisciplinary scientific research program, employing a range of research initiatives to identify, study and resolve environmental health risks. These initiatives are consistent with the MUSC role as a comprehensive state-supported health sciences institution and with the nation's need for new and better approaches to the solution of a complex and expansive array of environment-related health problems. The intrinsic capabilities of a comprehensive health sciences institution enable MUSC to be a national resource for the scientific investigation of environmental health issues. EBPs success as a nationally prominent research program is due, in part, to ...
2007-10-31
Environmental Biosciences Quarterly Report
Energy Technology Data Exchange (ETDEWEB)
In May 2002, the United States Department of Energy (DOE) signed Assistance Instrument Number DE-FC09-02CH11109 with the Medical University of South Carolina (MUSC) to support the Environmental Biosciences Program (EBP). This funding instrument replaces DOE Assistance Instrument Number DE-FC02-98CH10902. EBP is an integrated, multidisciplinary scientific research program, employing a range of research initiatives to identify, study and resolve environmental health risks. These initiatives are consistent with the MUSC role as a comprehensive state-supported health sciences institution and with the nation's need for new and better approaches to the solution of a complex and expansive array of environment-related health problems. The intrinsic capabilities of a comprehensive health sciences institution enable MUSC to be a national resource for the scientific investigation of environmental health issues. EBPs success as a nationally prominent research program is due, in part, to ...
2007-01-31
Environmental Biosciences Program Third Quarter Report, Year 2
Energy Technology Data Exchange (ETDEWEB)
In May 2002, the United States Department of Energy (DOE) signed Assistance Instrument Number DE-FC09-02CH11109 with the Medical University of South Carolina (MUSC) to support the Environmental Biosciences Program (EBP). This funding instrument replaces DOE Assistance Instrument Number DE-FC02-98CH10902. EBP is an integrated, multidisciplinary scientific research program, employing a range of research initiatives to identify, study and resolve environmental health risks. These initiatives are consistent with the MUSC role as a comprehensive state-supported health sciences institution and with the nation's need for new and better approaches to the solution of a complex and expansive array of environment-related health problems. The intrinsic capabilities of a comprehensive health sciences institution enable MUSC to be a national resource for the scientific investigation of environmental health issues. EBPs success as a nationally prominent research program is due, in part, to ...
2005-03-31
Environmental Biosciences Program Report for Year Three
Energy Technology Data Exchange (ETDEWEB)
In May 2002, the United States Department of Energy (DOE) signed Assistance Instrument Number DE-FC09-02CH11109 with the Medical University of South Carolina (MUSC) to support the Environmental Biosciences Program (EBP). This funding instrument replaces DOE Assistance Instrument Number DE-FC02-98CH10902. EBP is an integrated, multidisciplinary scientific research program, employing a range of research initiatives to identify, study and resolve environmental health risks. These initiatives are consistent with the MUSC role as a comprehensive state-supported health sciences institution and with the nation's need for new and better approaches to the solution of a complex and expansive array of environment-related health problems. The intrinsic capabilities of a comprehensive health sciences institution enable MUSC to be a national resource for the scientific investigation of environmental health issues. EBPs success as a nationally prominent research program is due, in part, to ...
2006-07-31
Environmental Biosciences Program Report for Year 3
Energy Technology Data Exchange (ETDEWEB)
In May 2002, the United States Department of Energy (DOE) signed Assistance Instrument Number DE-FC09-02CH11109 with the Medical University of South Carolina (MUSC) to support the Environmental Biosciences Program (EBP). This funding instrument replaces DOE Assistance Instrument Number DE-FC02-98CH10902. EBP is an integrated, multidisciplinary scientific research program, employing a range of research initiatives to identify, study and resolve environmental health risks. These initiatives are consistent with the MUSC role as a comprehensive state-supported health sciences institution and with the nation's need for new and better approaches to the solution of a complex and expansive array of environment-related health problems. The intrinsic capabilities of a comprehensive health sciences institution enable MUSC to be a national resource for the scientific investigation of environmental health issues. EBPs success as a nationally prominent research program is due, in part, to ...
2007-04-30
Environmental Biosciences Program Quarterly Report
Energy Technology Data Exchange (ETDEWEB)
In May 2002, the United States Department of Energy (DOE) signed Assistance Instrument Number DE-FC09-02CH11109 with the Medical University of South Carolina (MUSC) to support the Environmental Biosciences Program (EBP). This funding instrument replaces DOE Assistance Instrument Number DE-FC02-98CH10902. EBP is an integrated, multidisciplinary scientific research program, employing a range of research initiatives to identify, study and resolve environmental health risks. These initiatives are consistent with the MUSC role as a comprehensive state-supported health sciences institution and with the nation's need for new and better approaches to the solution of a complex and expansive array of environment-related health problems. The intrinsic capabilities of a comprehensive health sciences institution enable MUSC to be a national resource for the scientific investigation of environmental health issues. EBPs success as a nationally prominent research program is due, in part, to ...
2008-01-31
Environmental Biosciences Program Quarterly Report
Energy Technology Data Exchange (ETDEWEB)
In May 2002, the United States Department of Energy (DOE) signed Assistance Instrument Number DE-FC09-02CH11109 with the Medical University of South Carolina (MUSC) to support the Environmental Biosciences Program (EBP). This funding instrument replaces DOE Assistance Instrument Number DE-FC02-98CH10902. EBP is an integrated, multidisciplinary scientific research program, employing a range of research initiatives to identify, study and resolve environmental health risks. These initiatives are consistent with the MUSC role as a comprehensive state-supported health sciences institution and with the nation's need for new and better approaches to the solution of a complex and expansive array of environment-related health problems. The intrinsic capabilities of a comprehensive health sciences institution enable MUSC to be a national resource for the scientific investigation of environmental health issues. EBPs success as a nationally prominent research program is due, in part, to ...
2007-07-31
Environmental Biosciences Program Quarterly Report
Energy Technology Data Exchange (ETDEWEB)
In May 2002, the United States Department of Energy (DOE) signed Assistance Instrument Number DE-FC09-02CH11109 with the Medical University of South Carolina (MUSC) to support the Environmental Biosciences Program (EBP). This funding instrument replaces DOE Assistance Instrument Number DE-FC02-98CH10902. EBP is an integrated, multidisciplinary scientific research program, employing a range of research initiatives to identify, study and resolve environmental health risks. These initiatives are consistent with the MUSC role as a comprehensive state-supported health sciences institution and with the nation's need for new and better approaches to the solution of a complex and expansive array of environment-related health problems. The intrinsic capabilities of a comprehensive health sciences institution enable MUSC to be a national resource for the scientific investigation of environmental health issues. EBPs success as a nationally prominent research program is due, in part, to ...
2006-10-31
Environmental Biosciences Program Fourth Quarter Report
Energy Technology Data Exchange (ETDEWEB)
In May 2002, the United States Department of Energy (DOE) signed Assistance Instrument Number DE-FC09-02CH11109 with the Medical University of South Carolina (MUSC) to support the Environmental Biosciences Program (EBP). This funding instrument replaces DOE Assistance Instrument Number DE-FC02-98CH10902. EBP is an integrated, multidisciplinary scientific research program, employing a range of research initiatives to identify, study and resolve environmental health risks. These initiatives are consistent with the MUSC role as a comprehensive state-supported health sciences institution and with the nation s need for new and better approaches to the solution of a complex and expansive array of environment-related health problems. The intrinsic capabilities of a comprehensive health sciences institution enable MUSC to be a national resource for the scientific investigation of environmental health issues. EBPs success as a nationally prominent research program is due, in part, to its ...
2005-06-30
Ecological risk assessment of the east branch, Finniss River
International Nuclear Information System (INIS)
Quantitative ecological risk assessment (ERA) is a means whereby the risk posed by a toxicant in any system can be evaluated by comparing the distribution of its measured or modelled concentrations (water quality data (WQD)) with available information on the range of concentrations that are known to adversely affect biota within that, or similar, habitats (dose-response data (DRD)). Initially, the WQD are compared with regulatory criteria (e.g. ANZECC and ARMCANZ, 2000). If they fail this test, then, on the assumption that both data sets comprise subsets of the entire range of concentrations, probability density functions are derived assuming a standard distribution form a typically log-normal. In this paper, AQUARISK has been used to estimate the risk posed by copper in effluent from the Rum Jungle mine site, pre- and post-remediation, and the proportion of taxa likely to be affected in the East Branch (EB) of the Finniss River downstream of ...
2002-03-01
Differential effects of chronic ingestion of tritiated water on prenatal brain development
International Nuclear Information System (INIS)
Female rats were given tritiated drinking water (3 microCi/ml) from 30 days before mating up to and throughout pregnancy. At this low dose, the course and the outcome of pregnancy were normal. The differences between newborn body and cerebral weights of the treated rats and those of control animals were on the borderline of significance. In contrast, cerebral DNA and cerebral protein were highly significantly lower. In 30-35% of the treated population the DNA and protein values were more than 2 standard deviations (SD) below the mean values for the control population. Thus the number of the progeny of the mothers exposed to tritiated water that were considered to have outstandingly low levels of DNA and protein was 14-17 times greater than in the control group. The irradiated population also had 3-5% of severely affected individuals with cerebral DNA and protein values more than 2 SD below the mean of the experimental population. However, even ...
Development of radiological emergency preparedness technology
Energy Technology Data Exchange (ETDEWEB)
Large-scale field tracer experiments have been conducted on Ulchin, Wolsung and Daeduk sites for the purpose of validating FADAS and of analyzing the environmental characteristics around the nuclear sites. The most influential factor in atmospheric dispersion is the meteorological condition. During the experiment, meteorological data were measured on the release point and the selected positions among sampling points. Once radioactive materials are released to the atmosphere, members of public may be exposed through the environmental media such as air, soil and foods. Therefore, to protect the public, adequate countermeasures should be taken at due time for those exposure pathways. both processes, of justification and optimization are applied to a countermeasure simultaneously for decision-making. The work scope of Biological research for the radiation protection had contained the search of biological microanalytic methods for assessing the health effect by {gamma}-radiation and toxic ...
2000-04-01
Energy Technology Data Exchange (ETDEWEB)
US Department of Energy (DOE) Order 5820.2A (DOE, 1988) requires performance assessments on all new and existing low-level radioactive waste (LLW) disposal sites. An integral part of performance assessment is estimating the fluxes of radioactive gases such as radon-220 and radon-222. Data needs pointed out by mathematical models drive site characterization. They provide a logical means of performing the required flux estimations. Thorium-230 waste, consisting largely of thorium hydroxide and thorium oxides, has been approved for disposal in shallow trenches and pits at the LLW Radioactive Waste Management Site in Area 5 of the Nevada Test Site. A sophisticated gas transport model, CASCADR8 (Lindstrom et al., 1992b), was used to simulate the transport and fate of radon-222 from its source of origin, nine feet below a closure cap of native soil, through the dry alluvial earth, to its point of release into the atmosphere. CASCADR8 is an M-chain gas-phase radionuclide transport and fate ...
1993-12-01
System 80+{trademark} Standard Design: CESSAR design certification. Volume 9: Amendment I
Energy Technology Data Exchange (ETDEWEB)
This report, entitled Combustion Engineering Standard Safety Analysis Report -- Design Certification (CESSAR-DC), has been prepared in support of the industry effort to standardize nuclear plant designs. These volumes describe the Combustion Engineering, Inc. System 80{sup +}{trademark} Standard Design. This volume 9 discusses Electric Power and Auxiliary Systems.
1990-12-21
System 80+{trademark} Standard Design: CESSAR design certification. Volume 8: Amendment I
Energy Technology Data Exchange (ETDEWEB)
This report, entitled Combustion Engineering Standard Safety Analysis Report -- Design Certification (CESSAR-DC), has been prepared in support of the industry effort to standardize nuclear plant designs. These volumes describe the Combustion Engineering, Inc. System 80{sup +}{trademark} Standard Design. This volume 8 provides a description of instrumentation and controls.
1990-12-21
System 80+trademark Standard Design: CESSAR design certification
International Nuclear Information System (INIS)
This report, entitled Combustion Engineering Standard Safety Analysis Report -- Design Certification (CESSAR-DC), has been prepared in support of the industry effort to standardize nuclear plant designs. These volumes describe the Combustion Engineering, Inc. System 80"+trademark Standard Design. This volume 11 discusses Radiation Protection, Conduct of Operations, and the Initial Test Program.
Survey of state water quality standards for wetlands
Energy Technology Data Exchange (ETDEWEB)
This document summarizes the degree to which State water quality standards include wetlands in their definitions of State waters. The detailed review of other elements of standards, such as uses, criteria and antidegradation, is beyond the scope of this review. The purpose of this review is to provide a baseline of information for the development of EPA guidance and policies related to water quality standards for wetlands.
1989-08-17
Reference standard for carbonaceous impurity measurements in carbon nanotubes
Near-infrared spectroscopy is a convenient tool for measuring nanotube / carbonaceous impurities
2004-01-01
Plutonium Finishing Plant (PFP) Standards/Requirements Identification Document (S/RID)
International Nuclear Information System (INIS)
This Standards/Requirements Identification Document (S/RID) sets forth the Environmental Safety and Health (ESH) standards/requirements for the Plutonium Finishing Plant (PFP). This S/RID is applicable to the appropriate life cycle phases of design, construction, operation, and preparation for decommissioning. These standards/requirements are adequate to ensure the protection of the health and safety of workers, the public, and the environment.
1998-06-01
Industrial experience with an intelligent AC/DC standard
Energy Technology Data Exchange (ETDEWEB)
AC/DC voltage standards based entirely on solid-state references used as secondary, working, or transfer standards is widespread, although metrological performance is typically defined only via comparison with a higher level standard. The present report shows the improvements of the output metrological characteristics of an ac/dc calibrator by establishing three internal hierarchical levels of dc voltage references and by constant calibration of ac measuring circuits.
1989-04-01
Estimation of half-life values of actinide radionuclides
International Nuclear Information System (INIS)
... actinides americium 241 americium 242 americium 243 calibration standards
1986-04-15
Development of a Standard Data Base and Computer ...
... (Author). Descriptors : (*TERMINAL FLIGHT FACILITIES ... PROGRAMMING, HANDLING), QUEUEING THEORY, STOCHASTIC PROCESSES ...
1973-01-01
This document provides a technical basis for the revision of chemical effluent limitations guidelines for the Steam Electric Power Industry reflecting the Best Available Technology Economically Achievable (BATEA) for existing sources, New Source Performance Standards (NSPS) and Pretreatment Standards. The analysis of pollutants and the technologies applicable to their control has been based on specific waste streams of concern.
1980-09-01
This document presents the findings of a study of the Ink Manufacturing Industry for the purpose of developing effluent limitations and standards, and pretreatment standards for existing and new sources to implement Sections 301, 304, 306, 307 and 501 of ...
1979-01-01
Energy Technology Data Exchange (ETDEWEB)
The OSHA's chemical occupational exposure standard for laboratories is an outgrowth of the previously issued Hazard Communication Standard. The standard relieves laboratories from complying with general industry standards but does not require compliance with specific guidelines. The heart of the standard is the creation of a Chemical Hygiene Plan (CHP) in every laboratory. The CHP addresses major issues such as safety equipment and procedures, work practices and training, the designation of a chemical hygiene officer, and the provision of medical consultation and examination for affected employees. This new standard, in effect as of 31 January, 1991, presents yet another regulatory challenge to laboratory managers but also will ensure a safer work environment for laboratory workers.
1991-04-01
ISO - ISO Standards - TC 156 - Corrosion of metals and alloys
...ISO - ISO Standards - TC 156 - Corrosion of metals and alloys go to main navigation go to content area go to search International Standards for Business,...ISO Members FAQs Fr ISO Store Products ISO Standards By TC TC 156 Corrosion of metals and alloys ISO Store ISO Standards By ICS By ...aerospace standards Publications and e-products ISO Concept Database (ISO/CDB) Copyright TC 156 - Corrosion of metals and alloys Items to be displayed: Published ...responsibility of TC 156 Secretariat Standard and/or project Stage ICS 3ISO/WD 7441 Corrosion of metals and alloys Determination of bimetallic corrosion in outdoor ...
Extensions to the VME hardware and software standards for the physics community
Energy Technology Data Exchange (ETDEWEB)
With the ubiquitous availability of commercial VME modules and interface chips many experiments in all branches of Experimental Physics are turning to VME as the module packaging and backplane protocol of choice for application specific modules. The current VME backplane, electrical, and mechanical standards are clearly lacking when it comes to implementing the analogue and digital front end modules that Physics experiments rely on to provide the needed high speed and intelligent solutions to their data collection requirements. To address these needs the European ESONE and American VME-P committees are collaborating with the ANSII and ISO standards committees, and the VME VITA/VSO manufacturers associations, to define standard extensions to the VME protocols for such HEP needs as ``sparse data scans``, standard uses and implementations of previously user defined pins and connectors, ...
1995-10-01
Whole-body counting in the Marshall Islands
Energy Technology Data Exchange (ETDEWEB)
In 1978 the Marshall Islands Radiological Safety Program was organized to perform radiation measurements and assess radiation doses for the people of the Bikini, Enewetak, Rongelap and Utirik Atolls. One of the major field components of this program is whole- body counting (WBC). WBC is used to monitor the quantity of gamma- emitting radionuclides present in individuals. A primary objective of the program was to establish {sup 137}Cesium body contents among the Enewetak, Rongelap and Utirik populations. {sup 137}Cs was the only gamma-emitting fission radionuclide detected in the 1,967 persons monitored. {sup 137}Cs body burdens tended to increase with age for both sexes, and were higher in males. The average {sup 137}Cs dose Annual Effective Dose for the three populations was as follows: For Enewetak, the dose was 22{+-}4 {mu}Sv. For Utirik, the dose was 33{+-} 3 {mu}Sv. Since 1985 ...
1991-01-01
The somatically significant dose, SSD, and analog of the GSD, the genetically significant dose
International Nuclear Information System (INIS)
The medical applications of radiation comprise three main fields namely: Diagnostic Radiology, Radiotherapy and Nuclear Medicine. With the new weighting factors of ICRP (IC91a) the effective dose due to medical applications can be established. I is common to separate the effective dose into the genetic part and the somatic part, SED. In dealing with gonad doses it is important to account for the age of the person at the time of exposure as this will influence the number of children still to be expected from that person. The resulting dose will then be called the genetically significant dose, GSD. In a similar fashion this age factor will be important in considering the chance of tumor induction. The age of patients differs considerably from the average age of the general population. This age difference has to be accounted for if a comparison is to be made with other sources of ...
1991-11-01
Safety assessment for clearance of radioactive metal wastes from nuclear facility
Energy Technology Data Exchange (ETDEWEB)
Safety assessments for clearance of H-beam and valves, main radioactive metal wastes in Kori nuclear power plants, were carried out to derivate a decontamination factor for satisfying the dose limits of clearance level (Maximum individual dose: 10 {mu}Sv/y, collective dose: 1 man{center_dot}Sv/y) in Korea. Maximum individual dose and collective dose were evaluated by internal dose conversion factor which based on the concept of effective dose in ICRP publication 60. The results of maximum individual dose and collective dose is 139 {mu}Sv per year and 0.166 man{center_dot}Sv per year about H-beam, and 158 {mu}Sv per year and 0.468 man{center_dot}Sv per year about valves respectively. Demand decontamination factor satisfied with, which is respectively more than 13.9 and 15.8 for satisfying clearance ...
2003-10-01
Safety assessment for clearance of radioactive metal wastes from nuclear facility
International Nuclear Information System (INIS)
Safety assessments for clearance of H-beam and valves, main radioactive metal wastes in Kori nuclear power plants, were carried out to derivate a decontamination factor for satisfying the dose limits of clearance level (Maximum individual dose: 10 #mu#Sv/y, collective dose: 1 man#centre dot#Sv/y) in Korea. Maximum individual dose and collective dose were evaluated by internal dose conversion factor which based on the concept of effective dose in ICRP publication 60. The results of maximum individual dose and collective dose is 139 #mu#Sv per year and 0.166 man#centre dot#Sv per year about H-beam, and 158 #mu#Sv per year and 0.468 man#centre dot#Sv per year about valves respectively. Demand decontamination factor satisfied with, which is respectively more than 13.9 and 15.8 for satisfying clearance ...
2003-10-01
Lung dose calculations at kilovoltage x-ray energies using a model-based treatment planning system
International Nuclear Information System (INIS)
The determination of the dose to organs from diagnostic x rays has become important because of reports of radiation injury to patients from fluoroscopically guided interventional procedures. We have modified a convolution/superposition-based treatment planning system to compute the dose distribution for kilovoltage beams. We computed lung doses using this system and compared them to those calculated using the CDI3 organ dose calculation program. We also computed average lung doses from a simulated radiofrequency ablation procedure and compared our results to published doses for a similar procedure. Doses calculated using this system were an average of 20% lower for AP beams and 7% higher for PA beams than those obtained using CDI3. The ratio of the average dose to the lungs to the skin dose from the ...
2001-02-01
Tin-oxide-coated anodized aluminium selective absorber surfaces. Pt. 2. Aging and durability
Energy Technology Data Exchange (ETDEWEB)
Accelerated aging tests on tin-oxide-coated anodized aluminium selective absorber surfaces have been performed. It is shown that the tin oxide layer provides excellent protection for the anodized surface. The thermal stability of the double layer is equal to, or better than, the stability of the bare anodized surface. Both surfaces degrade very slowly at 450deg C. The anodic layer is porous and therefore not very scratch resistant and it degrades when exposed to humidity, both acidic and alcaline. It is shown that the tin oxide film, which is hard and chemically very stable, almost completely protects the anodized surface from chemical degradation. The mechanical wear resistance is also considerably improved. The optical selectivity does not quite match that of the the anodized surface, but the remarkable stability together with the solar parameters of {alpha}=0.91 and hemispherical emittance {epsilon}= 0.16 (normal emittance {epsilon}{sub n}=0.12) make this ...
1991-03-01
The distribution of Lyman-limit absorption systems during and after reionization
Lyman-limit absorption systems can play many important roles during and after cosmological reionization. Unfortunately, due to the prohibitively large dynamic range required, it is impossible to self-consistently include these systems in cosmological simulations. Using fast and versatile semi-numeric simulations, we systematically explore the spatial distribution of absorption systems during and following reionization. We self-calibrate the resulting number of absorbers to the mean free path (mfp) of the ionizing ultraviolet background (UVB), and present results at a given mfp and neutral hydrogen fraction. We use a simple optical depth criterion to identify the locations of absorbers. Our approach is fairly robust to uncertainties such as missing subgrid structure. Unlike at lower redshifts where the UVB is relatively uniform, at higher redshifts the fluctuations in the UVB and the HII morphology of reionization can drive the large-scale ...
2010-01-01
Seismic migration and absorbing boundaries with a one-way wave system for heterogeneous media
Energy Technology Data Exchange (ETDEWEB)
A first-order one-way wave system has been created based on characteristic analysis of the acoustic wave system and optimization of the dispersion relation. The authors demonstrate that this system is equivalent to a third-order scalar partial-differential equation which, for a homogeneous medium, reduces to a form similar to the 45{degree} paraxial wave equation. This system describes accurately waves propagating in a 2D heterogeneous medium at angles up to 75{degree}. The one-way wave system representing downgoing waves is used for a modified reverse time migration method. As a wavefield extrapolator in migration, the downgoing wave system propagates the reflection events backwards to their reflectors without scattering at the discontinuities in the velocity model. Hence, images with amplitudes proportional to reflectivity can be obtained from this migration technique. They present examples of the application of the new migration method to synthetic seismic data where P-P reflections ...
1996-07-01
Radiative transfer in a solar absorbing particle laden flow
A possible receiver configuration is a cavity in which a falling sheet of solid particles is directly irradiated by the concentrated solar flux passing through the aperture. Regardless of the particular geometry, the radiative transfer within the falling particle curtain must be studied in order to determine the net radiative heating rate for the particles. A discrete ordinate radiative transfer model has been developed to predict the radiative coupling within the falling particle curtain. The model determines how much energy is absorbed by the particles, how much is transmitted to the rear wall of the receiver, and determines the effects of particle scattering and thermal emission on the net radiation absorbed by the particles. The model accounts for the directional nature of the radiation field, particle scattering, and the wavelength dependence of the optical properties. The discrete ordinate model has been used to assess the influence of ...
1985-11-01
Parametric Resonance Ionization Cooling and Reverse Emittance Exchange for Muon Collider
Energy Technology Data Exchange (ETDEWEB)
Two methods to cool muon beams deeply below the limit conventionally established for the ionization cooling are proposed. In Phase Ionization Cooling (PIC), the beam is focused at wedge absorber plates each half of particle oscillation period by imposing a weak parametric resonance along the beam path. The resonance growth of particle amplitude is surmounted by the ionization cooling. At optimum, such arrangement results in reduction of each of two transverse emittances by an order of value in addition to the preceding 6D ionization cooling. Next, resonance focusing and transverse cooling can be continued in the regime of a fast Reverse Emittance Exchange (REMEX). Here, the sign of the absorber wedge is opposite to PIC while the dispersion increased. REMEX to be accompanied by the bunch lengthening and acceleration in order to maintain the relative energy spread at an appropriate level. The limitations due to energy straggling in ...
2005-09-18
Osmoregulation in the Avena coleoptile: control of solute uptake in peeled sections
Energy Technology Data Exchange (ETDEWEB)
Peeled Avena sativa coleoptile sections have been used to study the control of solute uptake under conditions where the uptake is not limited by the cuticular barrier. In the presence of 2% sucrose, auxin enhances the rate at which the total osmotic solutes increase, but this appears to be a response to the increased growth rate, inasmuch as the auxin effect is eliminated when growth is inhibited osmotically. When sections are incubated in sucrose or in 10 millimolar NaCl, the osmotic concentration increases until a plateau is reached after 8 to 24 hours. Auxin has no effect on the initial rate of increase in osmotic concentration. This difference in steady-state osmotic concentration is, in part, a response to auxin itself, as it persists when auxin-induced growth is inhibited osmotically. The upper limit for osmotic concentration does not appear to be determined by the turgor pressure, inasmuch as a combination of sucrose and NaCl gave a higher plateau osmotic concentration than did ...
1982-01-01
Advanced Flue Gas Desulfurization (AFGD) Demonstration Project, A DOE Assessment
The AFGD process as demonstrated by Pure Air at the Bailly Station offers a reliable and cost-effective means of achieving a high degree of SO{sub 2} emissions reduction when burning high-sulfur coals. Many innovative features have been successfully incorporated in this process, and it is ready for widespread commercial use. The system uses a single-loop cocurrent scrubbing process with in-situ oxidation to produce wallboard-grade gypsum instead of wet sludge. A novel wastewater evaporation system minimizes effluents. The advanced scrubbing process uses a common absorber to serve multiple boilers, thereby saving on capital through economies of scale. Major results of the project are: (1) SO{sub 2} removal of over 94 percent was achieved over the three-year demonstration period, with a system availability exceeding 99.5 percent; (2) a large, single absorber handled the combined flue gas of boilers generating 528 MWe of power, and no spares were ...
2001-08-31
A hydroxide mixture as working fluid for absorption heat pumps
Energy Technology Data Exchange (ETDEWEB)
Basic experimental investigations were carried out with an aqueous solution of a mixture of KOH and NaOH for use as an absorbent in absorption heat pumps. Due to its thermophysical properties this mixture allows temperature lifts from evaporator to absorber of more than 75 K (135 F) in a single-stage absorption chiller. Thermophysical and hydrodynamical properties of the solution were measured. Vapor-liquid-equilibrium data and specific heat capacities were determined for concentrations ranging from 35% up to 75% and temperatures up to 200 C (392 F). From these data the enthalpy of the solution was calculated. Additionally the crystallization temperatures, the density, and the viscosity of the solution were determined. The experimental equipment is described. The data are presented as polynomials and diagrams including experimental accuracy. An apparatus was constructed to measure heat and mass transfer coefficients of the absorption process ...
1996-11-01
Dosimetry limitations and a dose correction methodology for step-and-shoot IMRT
Energy Technology Data Exchange (ETDEWEB)
For the step-and-shoot intensity-modulated radiation therapy (IMRT) technique, the combination of high dose rate, multiple beam segments and low dose per segment can lead to significant differences between the planned dose and the dose delivered to the patient. In this technique, a dose delivery inaccuracy known as the 'overshoot' effect is caused by the dose servo control system. This typically occurs in the first and last beam segments and causes an over- and underdose, respectively. Some dose positional error in the segment sequence is also possible there. Commercial ionization chambers (RK-type) and radiographic Kodak films were used for the measurements. The reported results were obtained using the Pinnacle{sup 3}-V6.2 treatment planning system and a Varian Clinac 21 EX linear accelerator equipped with a 120-leaf ...
2006-02-07
The development of thyroid dose assessment software for nuclear or radiological emergency
International Nuclear Information System (INIS)
Objective: To develop software for assessment of dose to thyroid gland in emergencies resulting in the release of radioiodine. Methods: Based on procedures for thyroid monitoring and dose assessment introduced in IAEA publications (IAEA-TECDOC-1092 and EPR-MEDICAL-2005), a software was developed with Visual Basic 6.0 program to computerized the methods of thyroid dose estimation. Results: The intake of radioiodine and committed equivalent dose to thyroid could be estimated rapidly and accurately with the present software. Conclusion: The present software provide a practical and rapid tool for estimating thyroid doses received in emergencies resulting in the release of radioiodine by emergency workers and members of public, which is necessary for recommendation of further actions. (authors)
2006-12-01
Photon beam modelling with Pinnacle3 Treatment Planning System for a Rokus M Co-60 Machine
International Nuclear Information System (INIS)
The basic relationships of the convolution/superposition dose calculation technique are reviewed, and a modelling technique that can be used for obtaining a satisfactory beam model for a commercially available convolution/superposition-based treatment planning system is described. A fluence energy spectrum for a Co-60 treatment machine obtained from a Monte Carlo simulation was used for modelling the fluence spectrum for a Rokus M machine. In order to achieve this model we measured the depth dose distribution and the dose profiles with a Wellhofer dosimetry system. The primary fluence was iteratively modelled by comparing the computed depth dose curves and beam profiles with the depth dose curves and crossbeam profiles measured in a water phantom. The objective of beam modelling is to build a model of the primary fluence that the patient is exposed to, which can then be used for the ...
Energy Technology Data Exchange (ETDEWEB)
When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).
1991-08-01
International Nuclear Information System (INIS)
When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).
1991-01-01
Influence of the X-ray radiation on the lifetime of carriers in the p-n junctions of Si and Ge
International Nuclear Information System (INIS)
Lifetime of minority charae carriers in the Si and Ge p-n unctions has been measured by pulse method of conductivity modulation of base. Its dependence on the X-ray radiation dose has been investigated. Dependence of current transmission coefficients on the dose has been measured and their sharp decrease at low doses and the following saturation at high doses have been observed. Linear dependence of lifetime on X-ray radiation dose has been obtained. Resulting from the comparison of regularities of the change of lifetime due to current characteristics, it has been shown that X-ray radiation leads to the formation of the surface defects, influencing the change of current characteristics as well as to stationary structural defects, causing the decrease of lifetime of the charge carriers with the increase of X-ray radiation dose.
Effect of Nordic diets on ECOSYS model predictions of ingestion doses
British Library Electronic Table of Contents (United Kingdom)
The ECOSYS model is used to estimate ingestion dose in the ARGOS and RODOS decision support systems for nuclear emergency management. It is recommended that nation-specific values for several parameters are used in the model. However, this is generally overlooked when the systems are used in practice. We have estimated first year ingestion doses in two scenarios with wet and dry deposition of 137Cs, using the ECOSYS model. We calculated doses for each country using national dietary data while keeping all other parameters at their default values. These dose calculations were then used to estimate the variation in ingestion doses resulting from the variation in the diets only. The dietary data demonstrated that the average consumption of milk, meat and vegetables varied by a factor of 2-4 am...
2010-01-01
Dose enhancement in bone in electron beam therapy
Energy Technology Data Exchange (ETDEWEB)
This study investigated dose to bone tissue in electron beam therapy. Measurements were made using films and thermoluminescent dosimeters in a polystyrene phantom containing bone inhomogeneity for 15-MeV, 12-MeV, and 9-MeV electron beams. An increase in dose of approximately 18%, 12%, and 11%, for the three electron energies respectively, relative to the dose in polystyrene, was found for bone material having an electron density (relative to water) of 1.73. Measurements were also made using films for 15- and 9-Mev electrons in a phantom with a mandibular bone and teeth. A dose enhancement in bone of approximately 10% and 7%, respectively, for the two energies was found in the phantom where the electron density of bone was about 1.60. These results suggest that injury to bone is possible in those clinical situations where high doses of electrons are used for therapy.
1984-05-01
Dose enhancement in bone in electron beam therapy
International Nuclear Information System (INIS)
This study investigated dose to bone tissue in electron beam therapy. Measurements were made using films and thermoluminescent dosimeters in a polystyrene phantom containing bone inhomogeneity for 15-MeV, 12-MeV, and 9-MeV electron beams. An increase in dose of approximately 18%, 12%, and 11%, for the three electron energies respectively, relative to the dose in polystyrene, was found for bone material having an electron density (relative to water) of 1.73. Measurements were also made using films for 15- and 9-Mev electrons in a phantom with a mandibular bone and teeth. A dose enhancement in bone of approximately 10% and 7%, respectively, for the two energies was found in the phantom where the electron density of bone was about 1.60. These results suggest that injury to bone is possible in those clinical situations where high doses of electrons are used for therapy.
Analysis of photon beam exit dose using photon point kernels
International Nuclear Information System (INIS)
The Monte Carlo method is used to analyse the dose fall-off at the exit surface of a megavoltage photon beam. The convolution/superposition method of dose calculation using Monte-Carlo-generated homogeneous photon kernels is shown to be in error for exit dose calculation. Instead, photon kernels that incorporate modelling of the exit surface were generated, also using Monte Carlo, to analyse the problem, and the calculated dose fall-off using these kernels agrees well with measured data. In addition, the physics underlying the characteristics of the dose fall-off is analysed based on complete Monte Carlo modelling. Practical improvements to the convolution/superposition method are suggested. (Author).
Transuranic separation using organophophorus extractants adsorbed onto superparamagnetic carriers.
Energy Technology Data Exchange (ETDEWEB)
Polymeric coated ferromagnetic carriers with an absorbed layer of octyl(phenyl)-N,N-diisobutylcarbamoylmethylphosphine oxide (CMPO) diluted by tributyl phosphate (TBP) are being evaluated for application in the separation and the recovery of low concentrations of americium, plutonium, and uranium from nuclear waste solutions. Due to their chemical nature, these extractants selectively complex americium and plutonium contaminants onto the particles and the complexed particles can be recovered from the solution using a magnet. Physical and chemical characterization of the extractant-absorbed particles were performed by gamma and liquid scintillation counting, scanning electron microscopic (SEM) micrograph, and other physical measurements. Plutonium, americium, and uranium separations have been performed at various HNO{sub 3} and HCl concentrations. Parameters were studied to determine the limitations and capacity of the process. The status of the ...
1998-10-07
Thermal gradient humidification-dehumidification desalination system
Energy Technology Data Exchange (ETDEWEB)
A solar energy desalination process utilizing solar radiation directly for the evaporation of salt water is described. Ambient air takes on water vapor as the air passes through an evaporative medium. It is then directed between a saline water-covered, solar absorbing surface and a solar collecting housing. The resulting heated and moisture-saturated air is cooled in a heat exchange means where condensation of fresh water occurs. Simultaneously, cool salt water is utilized as the cooling water in the heat exchange means, and takes on the heat of condensation given up by the condensing vapor. The heated salt water from the heat exchange means is partially directed over the solar absorbing surface, and at least a portion of it is also directed to wet the evaporative medium. Several optional sub-processes are described for operation of the system during periods of reduced insolation, and an alternative process is described for operation of the ...
1982-12-14
International Nuclear Information System (INIS)
Labelling of "1"4C-M-ISP and its absorption, translocation and distribution in peanut and soybean seedling were studied. The results of experiments showed that the radioactive substance could be translocated in xylem and phloem of two kinds of plants. The root of peanut seedling absorbed "1"4C-M-ISP from the nutrient solution more strong than the root of soybean seedling did. After leaf treatment with "1"4C-M-ISP, the soybean seedling absorbed more radioactive substance than peanut seedling did. But the translocation's speed of radioactive substance in pnloem of two kinds of plants were similar.
1990-01-01
Glass-heat-pipe evacuated-tube solar collector
A glass heat pipe is adapted for use as a solar energy absorber in an evacuated tube solar collector and for transferring the absorbed solar energy to a working fluid medium or heat sink for storage or practical use. A capillary wick is formed of granular glass particles fused together by heat on the inside surface of the heat pipe with a water glass binder solution to enhance capillary drive distribution of the thermal transfer fluid in the heat pipe throughout the entire inside surface of the evaporator portion of the heat pipe. Selective coatings are used on the heat pipe surface to maximize solar absorption and minimize energy radiation, and the glass wick can alternatively be fabricated with granular particles of black glass or obsidian.
1981-08-06
Flux enhancement options for an LEU-fueled MIT reactor
International Nuclear Information System (INIS)
The Monte-Carlo transport code MCNP was used to evaluate possible arrangements of cores for the MIT Reactor using monolithic LEU fuel. Plate and moderator thicknesses were varied, and fixed absorbers and inner reflectors added in an effort to maximize available neutron fluxes at in-core and ex-core locations of experimental facilities. Addition of D_2O in the H_2O moderator was also evaluated. Comparisons of the fast, epithermal, and thermal fluxes were made at selected locations. Keff was also evaluated and critical blade heights compared with the existing HEU core. Results indicate that the LEU fluxes could approach HEU values with the use of a fueled in-core experimental facility, a fixed boron absorber spider and an inner beryllium reflector. (author)
2004-11-07
Enhanced carbon dioxide removal by promoted hot potassium carbonate in a split-flow absorber
Energy Technology Data Exchange (ETDEWEB)
In this work, a comprehensive model has been developed for the absorption of carbon dioxide into promoted hot potassium carbonate solution. The model, which is based on penetration theory, incorporates an extensive set of important reactions and takes into account the coupling between mass transfer and chemical kinetics. The penetration theory provides an appropriate absorption rate and enhancement factor for the chemical absorption. Operating data for carbon dioxide absorption into DEA-hot potassium carbonate solution has been compared with model predictions. The impact of parameters such inlet temperature of lean solution, promoter concentration, liquid split fraction, hot feed location and type of promoter on the performance of a split-flow absorber have been examined. The use of other promoters is an efficient way to enhance the carbon dioxide absorption, which has been discussed in this paper.
2004-07-01
Combined radiation and convection in absorbing, emitting, nongray gas-particulate tube flow
Energy Technology Data Exchange (ETDEWEB)
The interaction of thermal radiation with conduction and convection in thermally developing absorbing, emitting, nongray gas-particulate turbulent suspension flow through a circular tube is investigated. The contribution of thermal radiation is obtained through evaluation of the total hemispherical emittance of the particulate cloud and through evaluation of single band absorptances for molecular gases, modified to account for the interaction with the particles. The governing differential equation is derived as a (nonlinear) energy equation, coupled with integral equations to find the thermal radiation contributions. The energy equation is solved numerically by an implicit finite difference method with an iterative procedure. Qualitative results for Nusselt numbers are shown for a variety and range of parameters, such as optical thickness of particulates and single molecular gas bands, relative gas band position and band width, and temperature ratios (heated as ...
1987-05-01
Combined radiation and convection in absorbing, emitting, non-Gray gas-particulate tube flow
Energy Technology Data Exchange (ETDEWEB)
The interaction of thermal radiation with conduction and convection in thermally developing absorbing, emitting, non-gray gas particulate turbulent suspension flow through a circular tube is investigated. The contribution of thermal radiation is obtained through evaluation of the total hemispherical emittance of the particulate cloud and through evaluation of single band absorptances for molecular gases, modified to account for the interaction with the particles. The governing differential equation is derived as a (nonlinear) energy equation, coupled with integral equations to find the thermal radiation contributions. The energy equation is solved numerically by an implicit finite difference with its iterative procedure. Qualitative results for Nusselt numbers are shown for a variety and range of parameters, such as optical thickness of particulates and single molecular gas bands, relative gas band position and band width, and temperature ratios (heated as well as ...
1985-01-01
Chatter resistance of non-uniform turning bars with attached dynamic absorbers—Analytical approach
British Library Electronic Table of Contents (United Kingdom)
Forced harmonic vibration of a non-uniform elastic beam with attached dynamic vibration absorbers (DVA) is studied. Analytical approximation of the solution is obtained by the functional perturbation method (FPM). The problem has application to cutting tools operations where the resistance of the tool holder against regenerative chatter can be enhanced by optimizing the real part of the frequency response function (FRF). A test case of a beam with step-like heterogeneity and single DVA at the tip shows that the FPM solution is very accurate for up to ?40 percent deviation in both stiffness and mass density. Using the analytical results and Sims approach, optimal DVA tuning is found for each set of beam heterogeneity parameters by solving a set of nonlinear algebraic equations numer...
2010-01-01
Absorption of carbonyl sulfide in aqueous methyldiethanolamine
Energy Technology Data Exchange (ETDEWEB)
The absorption of carbonyl sulfide in aqueous methyldiethanolamine (MDEA) was studied over a range of temperatures and MDEA concentrations. MDEA is commonly used for selective absorption of hydrogen sulfide in the presence of carbon dioxide. However, sulfur in the form of COS may also be present and it is necessary that estimates of absorption rates of this compound be made. The objective of this study is to determine the physiochemical properties needed to predict COS absorption rates in aqueous MDEA. Free gas solubility and the diffusivity of COS in MDEA solutions were measured over the temperature range 15 to 40{sup 0}C for MDEA concentrations up to 30 weight per cent using the nitrous oxide analogy method. Solubilities were measured volumetrically in an equilibrium cell and diffusivities were measured using a laminar liquid jet absorber. The kinetics of the reaction between COS and MDEA were studied by measuring absorption rates in a single wetted-sphere ...
1988-01-01
Global residential appliance standards
Energy Technology Data Exchange (ETDEWEB)
In most countries, residential electricity consumption typically ranges from 20% to 40% of total electricity consumption. This energy is used for heating, cooling, refrigeration and other end-uses. Significant energy savings are possible if new appliance purchases are for models with higher efficiency than that of existing models. There are several ways to ensure or encourage such an outcome, for example, appliance rebates, innovative procurement, and minimum efficiency standards. This paper focuses on the latter approach. At the present time, the US is the only country with comprehensive appliance energy efficiency standards. However, many other countries, such as Australia, Canada, the European Community (EC), Japan and Korea, are considering enacting standards. The greatest potential impact of minimum efficiency standards for appliances is in the developing countries (e.g., China and India), where ...
1993-03-01
ETE-EVAL: a methodology for D and D cost estimation
International Nuclear Information System (INIS)
In compliance with Article 20 of the sustainable radioactive materials and waste management act dated 28 June 2006, the CEA and AREVA are required every three years to revise the cost of decommissioning their facilities and to provide the necessary assets by constituting a dedicated fund. For the 2007 revision the CEA used ETE-EVAL V5. Similarly, AREVA reevaluated the cost of decontaminating and dismantling its facilities at La Hague, as the previous estimate in 2004 did not take into account the complete cleanup of all the structural work. ETE-EVAL V5 is a computer application designed to estimate the cost of decontamination and dismantling of basic nuclear installations (INB). It has been qualified by Bureau Veritas and audited. ETE-EVAL V5 has become the official software for cost assessment of CEA civilian and AREVA decommissioning projects. It has been used by the DPAD (Decontamination and Dismantling Projects Department) cost assessment group to estimate the cost of ...
International Nuclear Information System (INIS)
Purpose: To determine if involved field radiation (IF) is equivalent to standard whole bone radiation (SF) in local tumor control; to establish patterns of failure following treatment; and to determine response, event free (EFS) and overall survival rates from multi-disciplinary therapy in Ewing's Sarcoma (ES). Materials and Methods: Between 1983 and 1988, 184 children with ES were enrolled onto POG 8346. 178 (97%) met eligibility criteria; 6 had non-ES pathology. Induction treatment of Cyclophosphamide/Adriamycin (C/A) x 12 weeks was followed by local treatment either surgery or radiation therapy (XRT) and C/A, Dactinomycin and Vincristine for 50 weeks. Resection was advised for patients with small primary tumors if accomplished without functional loss. 40 patients were randomized to receive SF, whole bone XRT to 39.6 Gy plus a 16.2 Gy boost (total 55.8 Gy) or IF to 55.8 Gy while 84 were assigned to IF XRT. Results: Of 179 eligible patients, 141 (79%) had ...
UK PubMed Central (United Kingdom)
For intensity modulated radiation treatment (IMRT) dose reconstruction, multileaf collimator (MLC) log files have been shown applicable for deriving delivered fluence maps. However, MLC log files are...Full Text Available
2008-11-01
UK PubMed Central (United Kingdom)
1. The antihypertensive efficacy and tolerability of a low dose combination of the angiotensin converting enzyme inhibitor ramipril (2.5 mg) and the extended release formulation of the dihydropyridine...Full Text Available
1993-10-01
TLD array for precise dose measurements in stereotactic radiation techniques
International Nuclear Information System (INIS)
We developed a new TLD array for precise dose measurement and verification of the spatial dose distribution in small radiation targets. It consists of a hemicylindrical, tissue-equivalent rod made of polystyrene with 17 parallel moulds for an exact positioning of each TLD. The spatial resolution of the TLD array was evaluated using the Leskell spherical phantom. Dose planning was performed with KULA 4.4 under stereotactic conditions on axial CT images. In the Leksell gamma unit the TLD array was irradiated with a maximal dose of 10 Gy with an unplugged 14 mm collimator. The doses delivered to the TLDs were rechecked by diode detector and film dosimetry and compared to the computer-generated dose profile. We found excellent agreement of our measured values, even at the critical penumbra decline. For the 14 mm and 18 mm collimator and for the 11 mm collimator ...
1996-12-01
Somatic and genetic effects of small doses of ionizing radiations in man
International Nuclear Information System (INIS)
Estimations on the somatic and genetic effects of small doses of ionizing radiations in Man have been proposed by the Advisory Committee on the Biological Effects of Ionizing Radiation, set up by the U.S. National Academy of Sciences. They have been published in an important report, issued in 1972, from which we briefly analyze here the Chapter dealing with the somatic effects. Small doses of raditions are expected to promote only carcinogenic effects. After a rapid survey of the human experience on which the estimations are based, as regards the latent period of cancers, the plateau region (period of high risk) and the absolute and relative risk expressed per rem, per 10"6 persons, per year, for leukaemia (having the highest risk) and for the ''other cancers''. These estimations were obtained by linear extrapolation to the 1 rem level from observations made after irradiation at relatively high dose levels and much higher ...
1976-01-01
Single-dose pharmacokinetics of ceftriaxone in healthy Chinese adults.
UK PubMed Central (United Kingdom)
The pharmacokinetics of ceftriaxone were investigated in six healthy mainland Chinese adults (four males and two females). A single 1.0-g dose was administered intravenously or intramuscularly in a...Full Text Available
1985-02-01
UK PubMed Central (United Kingdom)
AimsTo assess the tolerability and pharmacokinetic profile of single and repeat doses of the oral matrix metalloproteinase inhibitor marimastat in healthy male volunteers.Full Text Available
1998-01-01
Range and modulation dependencies for proton beam dose per monitor unit calculations
UK PubMed Central (United Kingdom)
Calculations of dose per monitor unit (D∕MU) are required in addition to measurements to increase patient safety in the clinical practice of proton radiotherapy. As in conventional photon and...Full Text Available
2009-02-01
Radiation risks for medical applications
International Nuclear Information System (INIS)
The achievements made in the field of radiation protection over the past 20 years are outlined. Risk analysis as applied to medicine is considered and genetic significant doses, genetic risks, somatic effective doses and somatic risks are discussed. (C.F.).
1980-05-31
UK PubMed Central (United Kingdom)
Low dose methotrexate has been used effectively for various rheumatic and non-rheumatic diseases. Three cases of Pneumocystis carinii pneumonia occurring during treatment of rheumatoid arthritis with...Full Text Available
1991-03-01
UK PubMed Central (United Kingdom)
BackgroundThe aim of this study was to compare and to validate different dose calculation algorithms for the use in radiation therapy of small lung lesions and to optimize the treatment...Full Text Available
UK PubMed Central (United Kingdom)
The reference medium for brachytherapy dose measurements is water. Accuracy of dose measurements of brachytherapy sources is critically dependent on precise measurement of the source–detector...Full Text Available
2010-01-01
Milk residues and performance of lactating dairy cows administered high doses of monensin
UK PubMed Central (United Kingdom)
AbstractMilk residues and performance were evaluated in lactating cows that were fed up to 10 times the recommended dose of monensin. Following an acclimatization period of 14 d, during...Full Text Available
2005-07-01
Energy Technology Data Exchange (ETDEWEB)
The purpose of this report is to summarize the assumptions, dose factors, consumption rates, and methodology used to evaluate potential radiation doses to persons who may eat contaminated wildlife or contaminated plants collected from the Hanford Site. This report includes a description of the number and variety of wildlife and edible plants on the Hanford Site, methods for estimation of the quantities of these items consumed and conversion of intake of radionuclides to radiation doses, and example calculations of radiation doses from consumption of plants and wildlife. Edible plants on the publicly accessible margins of the shoreline of the Hanford Site and Wildlife that move offsite are potential sources of contaminated food for the general public. Calculations of potential radiation doses from consumption of agricultural plants and farm animal products are made routinely and ...
1990-10-01
International Nuclear Information System (INIS)
For the risk estimate of fatal malignancies, an effective dose was proposed on the basis of the assumption that the risk should be equal whether the whole body irradiated uniformly or whether there is non-uniform irradiation. The effective dose was defined by the product of organ or tissue doses and a weighting factor representing the proportion of risk factor for a fatal malignancy resulting from organ or tissue irradiation to the total malignant factor. The risk of malignancies can be derived by multiplying the malignant significant factor by the product of the risk factor and the effective dose. For the genetic risk, a significant factor was a relative child expectancy and organ or tissue doses were gonad doses. And, for the leukemogenic risk, a significant factor was the leukemia significant factor and organ or tissue dose was mean bone ...
1980-01-01
Metabolism of iodomethane in the rat
UK PubMed Central (United Kingdom)
1. The LD50 of iodomethane orally administered to rats is 76mg./kg. body wt. but repeated daily doses of 30–50mg./kg. body wt. are without effect. 2. Oral doses of iodomethane to...Full Text Available
1966-01-01
Low-Dose, Off-Label Drotrecogin Alfa (Xigris) In Severe Sepsis
UK PubMed Central (United Kingdom)
Objective:In this article, we describe a successful low-dose, off-label usage of drotrecogin alfa (Xigris), given at 18 mcg/kg per hour, in a patient with severe sepsis who had an...Full Text Available
2008-08-01
UK PubMed Central (United Kingdom)
ObjectiveTo assess the efficacy and safety of low dose adrenaline injected subcutaneously to prevent acute adverse reactions to polyspecific antivenom serum in patients admitted...Full Text Available
1999-04-17
Long-term effects of inhaled uranyl nitrate in rats
International Nuclear Information System (INIS)
Rats were exposed to aerosols of "2"3"3U and "2"3"2U nitrate in a study of the long-term biological effects. Preliminary radiation dose estimates show lung > skeleton > kidney in each dose group.
1977-05-01
Isochron measurements of naturally irradiated K-feldspar grains
International Nuclear Information System (INIS)
The equivalent doses of K-feldspar grains in a range of grain sizes from 90 to 250#mu#m diameter were measured using a single-aliquot regenerative-dose protocol for the infrared stimulated luminescence (IRSL) signals for two samples of desert sand. The equivalent doses for each sample were compared with that for the 125-150#mu#m grains of quartz from the same samples. The results suggested that the K-feldspar equivalent doses were underestimated because of anomalous fading. Measurements of the decay of the IRSL signals following laboratory irradiation for these two samples, and an additional one from a previously published isochron study, showed anomalous fading during the period of laboratory storage. The decay rate was about 3% per decade for all samples and was independent of the grain size used. Using plots of equivalent doses for K-feldspars as a function of their calculated ...
2007-09-01
Inhibition of exercise-induced asthma by nifedipine: a dose-response study.
UK PubMed Central (United Kingdom)
1. The effect of three single doses of nifedipine on exercise-induced asthma has been examined in 11 asthmatic subjects. 2. On four separate days patients undertook 6 min of exercise on a treadmill...Full Text Available
1987-10-01
Induction of tumors by screening mammography
International Nuclear Information System (INIS)
Somatic radiation doses are recognized to be possible factors of carcinogenesis. In correctly performed mammography, however, even as screening test, the radiation dose does not reach such an order of magnitude that the benefit of the procedure as to prevention of breast cancer is called into question.
1983-01-01
Estimation of frequency, population doses and stochastic risks in brachytherapy in Japan, 1983
International Nuclear Information System (INIS)
Based on the replies to a questionnaire distributed throughout Japan in 1983, genetically significant dose (GSD), per Caput mean bone marrow dose (CMD), leukemogenically significant dose (LSD), malignantly significant dose (MSD), and per Caput effective dose equivalent (EDE) from using small sealed radiation sources for radiotherapy were estimated. Annual frequencies of brachytherapy were estimated to be 2.6 x 10"3 for men and 36.3 x 10"3 for women, with a total of 38.9 x 10"3. The annual frequencies of using afterloading technique were 0.3 x 10"3 for men and 18.8 x 10"3 for women, with a total of 19.1 x 10"3. The annual population doses per person were 7.9 nGy for GSD, 118 #mu#Gy for CMD, 19.3 #mu#Gy for LSD, 172 #mu#Gy for MSD, and 428 #mu#Gy for EDE. The annual collective effective dose equivalent was estimated to be 5.13 x 10"4 man Sv. ...
1988-01-01
Epidemiological survey of the effects of low level radiation dose: a comparative assessment
Energy Technology Data Exchange (ETDEWEB)
This volume presents the collations tables of a six volume comparative epidemiological survey of the effects of low level radiation dose. Data are collated for the effects observed in the following irradiated groups:- Preconception irradiation, intra-uterine irradiation, childhood irradiation, adult irradiation. (UK).
1993-10-01
International Nuclear Information System (INIS)
The genetically significant dose (GSD) is an index variable which exclusively allows to describe the genetic risk in the progeny of a population due to the application of ionizing radiation and radioactive substances in one part of this population. It may result in wrong interpretation of population exposure at increasing incidence of examinations in a population involving ionizing radiation and radioactive drugs at simultaneously increasing application of alternative methods in children and adolescents owing to the fact that it indicates a downward trend although somatic exposure of this population has increased. Therefore, it is recommended to state both the GSD and the level of somatic radiation exposure of the population taken from the individual sources for the comparison and assessment of radiation exposure from various sources in future. Although the somatically significant dose constitutes the suitable variable complementary to GSD in ...
1984-06-01
ESR dosimetry of irradiated chicken legs and chicken eggs
Energy Technology Data Exchange (ETDEWEB)
Ionising radiation induces stable free radicals in chicken bones and in the shell of chicken eggs which can be detected, by the electrons spin resonance (ESR) technique, well beyond the shelf-life of the food and can be used for dosimetry. The method usually adopted to evaluate ``a posteriori`` the dose given during the ionising radiation treatment of food, is the dose additive method. To assess the dose, the ESR signal amplitude of the irradiated food (bone or egg shell in the present case) is measured and then the dose-effect relationship is obtained by re-irradiating the sample with some additive doses (usually of 1 kGy). The dose-effect curve is back-extrapolated and the initial given dose determined. At the Istituto Superiore di Sanita (ISS), Rome, Italy, a research programme was approved two years ago aimed to, (1) study new ...
1996-12-31
UK PubMed Central (United Kingdom)
PurposeTo investigate the influence of inhomogeneity corrections on stereotactic treatment plans for non-small cell lung cancer and determine the dose delivered to the PTV and OARs.Full Text Available
UK PubMed Central (United Kingdom)
IntroductionThe optimal dialysis dose for the treatment of acute kidney injury (AKI) is controversial. We sought to evaluate the relationship between renal replacement therapy (RRT)...Full Text Available
2009-01-01
International Nuclear Information System (INIS)
An earlier representation of the radial distribution of dose about the path of a heavy ion in liquid water is modified and extended to include silicon, lithium fluoride, and sodium iodide. 6 refs., 5 figs., 1 tab.
1989-09-01
A randomized-controlled trial of low-dose doxycycline for periodontitis in smokers
UK PubMed Central (United Kingdom)
Background/AimTobacco use reduces the effect of non-surgical periodontal therapy. Host-modulation with low-dose doxycycline (LDD) might favour repair and promote...Full Text Available
2007-04-01
Status of the ANS low power and shutdown PRA standard
Energy Technology Data Exchange (ETDEWEB)
The Low Power and Shutdown (LPSD) PRA (Probabilistic Risk Assessment) Standard (ANS-58.22) is currently being drafted by a Writing Group under the auspices of the Risk Informed Standards Committee of the American Nuclear Society (ANS). The Writing Group includes representatives from nuclear utilities, US Nuclear Regulatory Commission (NRC), national laboratories, universities, and consultants with substantial experience producing LPSD PRAs. This draft standard is scheduled to be released for public comment in the second quarter of 2004, with publication by the end of 2004. The LPSD PRA Standard is based on a mature technology that shares many requirements with full power PRAs. It will provide specific methods and criteria whereby PRAs of appropriate quality and scope can be used in the conduct of plant decision-making and other activities, including addressing NRC requirements. This paper presents the ...
2004-07-01
International Nuclear Information System (INIS)
The Institute of Electrical and Electronic Engineers (IEEE) standards for the quality assurance requirements for the design and manufacture of Class 1E instrumentation and electric equipment for a nuclear power generating station are presented. This standard establishes Quality Assurance Program requirements for electrical manufacturers. This standard, used in conjunction with ANSI N45.2-1977 and the supplemental standards to the extent referenced in this standard, is intended to meet the requirements of 10CFR50, Appendix B. These requirements are intended to assure that Class 1E instrumentation and electric equipment are responsibly engineered and manufactured from proper materials, that the manufacturing processes and practices are controlled, and that the manufacturing process produces a product of the required quality for Class 1E application.
International Nuclear Information System (INIS)
Significant new nuclear-specific software standards have recently been adopted under the sponsorship of the American Nuclear Society and the American Society of Mechanical Engineers. The interest of the US Nuclear Regulatory Commission has also been expressed through their issuance of NUREG/CR-4640. These efforts all indicate a growing awareness of the need for thorough, referenceable expressions of the way to build in and evaluate quality in nuclear software. A broader professional perspective can be seen in the growing number of software engineering standards sponsored by the Institute of Electrical and Electronics Engineers (IEEE) Computer Society. This family of standards represents a systematic effort to capture professional consensus on quality practices throughout the software development life cycle. The only omission-the implementation phase-is treated by accepted American National Standards ...
1988-06-12
Somatic radiation risk in X-ray diagnostics
Energy Technology Data Exchange (ETDEWEB)
The authors give a survey of the somatic radiation risk in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk.
1983-12-01
Somatic radiation risk in X-ray diagnostics
International Nuclear Information System (INIS)
The authors give a survey of the somatic radiation ris in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk. (orig.).
1983-01-01
Savannah River Site dose control
Energy Technology Data Exchange (ETDEWEB)
Health physicists from the Brookhaven National Laboratory (BNL) visited the Savannah River Site (SRS) as one of 12 facilities operated by the Department of Energy (DOE) contractors with annual collective dose equivalents greater than 100 person-rem (100 person-cSv). Their charter was to review, evaluate and summarize as low as reasonably achievable (ALARA) techniques, methods and practices as implemented. This presentation gives an overview of the two selected ALARA practices implemented at the SRS: Administrative Exposure Limits and Goal Setting. These dose control methods are used to assure that individual and collective occupational doses are ALARA and within regulatory limits.
1992-06-01
Review of electron beam therapy physics
Energy Technology Data Exchange (ETDEWEB)
For over 50 years, electron beams have been an important modality for providing an accurate dose of radiation to superficial cancers and disease and for limiting the dose to underlying normal tissues and structures. This review looks at many of the important contributions of physics and dosimetry to the development and utilization of electron beam therapy, including electron treatment machines, dose specification and calibration, dose measurement, electron transport calculations, treatment and treatment-planning tools, and clinical utilization, including special procedures. Also, future changes in the practice of electron therapy resulting from challenges to its utilization and from potential future technology are discussed. (review)
2006-07-07
Projection techniques in diagnostic radiography discussed with regard to required dose
International Nuclear Information System (INIS)
The paper presents information in the form of data, tables and diagrams compiled to a broad but very up-to-date survey of required radiation for the various most frequently performed X-ray examinations of patients. The required dose is discussed from the point of view of radiation protection, defining the inevitably administered dose to the skin, the frequency of examinations, and the diagnostic image quality as the main three factors to be observed, as these determine the radiation dose to the patient and to the personnel. The somatic risks of radiography examinations are a point of main interest. (DG).
1990-09-01
Patient doses in the Netherlands. [X-ray diagnosis and radiotherapy
Energy Technology Data Exchange (ETDEWEB)
Contributions to the population dose due to medical applications of ionising radiation are presented. It appears that contributions due to radiotherapy and X ray diagnosis are of comparable magnitude. To account for the age dependency of the radiation risks, contributions in terms of somatically significant dose equivalent are calculated as 0.3 mSv per caput per annum for X ray diagnosis and as 0.2 mSv per caput per annum for radiotherapy, the latter referring to only doses to organs outside the target volume. (author).
1991-01-01
Organ doses to atomic bomb survivors during photofluorography, fluoroscopy and computer tomography
Energy Technology Data Exchange (ETDEWEB)
Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).
1991-08-01
Organ doses to atomic bomb survivors during photofluorography, fluoroscopy and computer tomography
International Nuclear Information System (INIS)
Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).
1991-01-01
New concepts in risk assessment for patients with radiological treatment
International Nuclear Information System (INIS)
In radiation risk assessment it must be differentiated between somatic and genetic effect on the one hand as well as between stochastic and non-stochastic effect on the other. According to definitions of the ICRP report 26 the limit for the dose equivalent of all tissues prevents non-stochastic radiation effects. With stochastic radiation effects probably exist no threshold doses; therefore the ALARA principle must be applied concerning radiation protection. The individual risk by stochastic radiation effects in its linear, linear-quadratic and quadratic extrapolations, respectively, is discussed in detail. The effective stochastic dose equivalent (H/sub eff/) as well as collective dose and collective damage are outlined.
1986-01-01
However, market based pricing doses not apply where the pricing .... the reimbursable work, market based pricing does not apply. 040202. ...
International Nuclear Information System (INIS)
During one year more than 40,000 items of information on radiation exposure of personnel involved in the handling of radiation sources and more than 5,000,000 items on irradiation of other people are collected in the authors' laboratory. Considerable progress in assessment of mean annual gonad dose of genetically sifnificant dose was attained by means of an algorithm for a personal computer. This simple and inexpensive system has led to a higher accuracy in the application of protective measures. (author).
1985-10-22