With accurate calculation algorithms in inverse planning for beamlet-based intensity modulated radiotherapy (IMRT), it takes time to calculate the dose matrix, which represents the dose distribution of each beamlet element to each voxel for unit fluence. To reduce the calculation time, coarse or approximate algorithms are often a choice, but this results in a final dose distribution that cannot reflect the real value. In addition, it is necessary to test if a coarse algorithm is capable of calculating the dose matrix of beamlets. In this work, simulated dynamics optimization algorithm was applied to optimize the segment weight to minish the dose error from the dose matrix calculation. After calculating the dose matrix by ray-tracing algorithm which takes into account just the primary component of ...
First, absorbeddose at entrance surface was measured in routine mammography. Secondly, a possibility of dose reduction after introduction of Fuji computed radiography (FCR) system was examined. In a total of 350 mammographic studies including craniocaudal and medilateral projections, average thickness of compressed breast was less than 4 cm and most frequently recorded absorbeddose was 0.2-0.3 cGy (200-300 mrad). Minimum dose to obtain clinically acceptable mammograms in FCR system was estimated by comparing image quality of routine versus reduced dose studies. It was concluded that absorbeddose could be reduced to 1/4 of routine dose without creating significant drawback in diagnosis. (author).
While there have been many experimental and calculational investigations on absorbeddose distribution in the patient resulting from conventional X-ray procedures, such data for computerized tomography (CT) are still sparse. As this diagnostic procedure has shown a rapid increase in application during recent years, we have determined absorbeddose to body organs in a human phantom resulting from CT examinations. The exposure model consists of the heterogeneous MIRD-5 phantom and a suitable Monte-Carlo method to calculate absorbeddose to organs of interest. The exposure conditions are specified according to the exposure specifications of a CT-scanner currently in use. The calculations cover the range of body tissues of interest in terms of organ absorbeddoses as well as a risk weighted absorbed ...
Gel dosimetry is a new dosimetry method applied in radiation therapy. Gel dosimeters consist of a radiation sensitive gel, which can integrate absorbeddoses from several radiation sources or beams. The dose to the gel can be evaluated by magnetic resonance imaging (MRI), a procedure that is the focus of the present thesis. A robust tool for the evaluation of the nonuniformity in MRI has been developed, the Deviation Image method. Unlike previously presented methods, the Deviation Image method includes all nonuniformity variations across a phantom surface and is insensitive to stochastic noise. Methods for the estimation of stochastic noise were analyzed in terms of sensitivity to nonuniformities. A method that averages the stochastic noise level over five regions over the phantom surface, and a method that assesses the stochastic noise level from the background, were found to be the methods of choice. Pronounced MR image ...
A method has been developed for calibration of CT-numbers to volumetric electron density distributions using tissue substitutes of known elemental composition and experimentally determined electron density. This information have been used in a dose calculation method based on photon and electron interaction processes. The method utilizes a convolution integral between the photon fluence matrix and dose distribution kernels. Inhomogeneous media are accounted for using the theorems of Fano and O'Connor for scaling dose distribution kernels in proportion to electron density. For clinical application of a calculated dose plan, a method for prediction of accelerator output have been developed. The methods gives the number of monitor units that has to be given to obtain a certain absorbeddose to a point inside an irregular, inhomogeneous object. The method for ...
The conventional IMRT planning process involves two stages in which the first stage consists of fast but approximate idealized pencil beam dose calculations and doseoptimization and the second...Full Text Available
Irradiation of the human body in diagnostic X-ray procedures results in different absorbeddoses in the various body organs. A somatic dose index in formulated by applying the relative sensitivity of the human to each of the most important somatic effects and utilizing the absorbeddose in the affected organs. This quantity is used to convey a cumulative somatic impact and is computed for common radiographic views in diagnostic radiology as a function of beam quality for a nominal IR entrance exposure. Using typical X-ray beam qualities and exposures, the frequency of the various radiographic views that make up an examination and the frequencies of the various examinations in the national population, illustrative examples of the application of the somatic dose index are presented. (author).
Purpose Study the radiolysis of solid-state metoclopramide hydrochloride at various absorbeddoses. Elucidate the structure of the degradation products to gain information on the radiolysis mechanisms. Methods Solid-state metoclopramide samples were irradiated at several doses with gamma rays and high-energy electrons to evaluate the influence of the dose rate. High-performance liquid chromatography with a diode array detector was used to measure the chemical potency as a function of the absorbeddose and to quantify the degradation products. The characterization of degradation products was performed by liquid chromatography/atmospheric pressure chemical ionization/tandem mass spectrometry. Results The degradation of solid-state metoclopramide after irradiation was negligible. No qualitati...
The current primary standards at NPL for the measurement of absorbeddose to water in high energy photon and electron beams are graphite calorimeters. However, the quantity of interest in radiation dosimetry is absorbeddose to water. Therefore, a new absorbeddose to water standard based on water calorimetry has been developed for use in high energy photon and electron beams. The calorimeter operates at 4 deg C, with temperature control being provided by liquid cooling. The sealed glass inner vessel of the calorimeter was designed to minimise the effect of non-water materials on the measurement of absorbeddose. The temperature sensing thermistor probes were designed and constructed so that glass is the only material in contact with high purity water inside the vessel. Initial measurements of ...
Abstract The characteristics of desulfurization and denitrification with composite absorbent were researched through aqueous absorption experiments. The removal efficiencies of SO2 and NO were up to 100 and 95%, respectively. The composite absorbent included NaClO2 and component M. Existence of component M in the solution could reduce the absorbent cost compared with using sodium chlorite alone. Chlorine dioxide, as main reaction intermediate product, participated in oxidation reaction. The optimal experimental conditions involved NaClO2 concentration of1.13 mmol/L, solution pH of 5.5, molar ratio (M/NaClO2) of 4.1, reaction temperature of 323 K. The optimal solution pH and reaction temperature were both in the required ranges of limestone-gypsum wet flue gas desulfurization (FGD) process....
Wood-polymer composites (WPC) have been prepared of pinewood with different monomers using Gamma radiation: acrylamide, butyl acrylate, butyl methacrylate, styrene, acrylonitrile, and polyester. The polymer loading was determined as a function of monomer concentration and absorbeddose. The data show that polymer loading increases by increasing the monomer concentration. In two cases, BMA and polyester, the polymer loading decreases at high concentrations. This can be explained by the increase of the viscosity. Thus the diffusion of the compound into bulk would be slower. The absorbeddose seems to play a positive role in enhancing the polymer loading by increasing the dose. The mechanical properties, tensile and compression strength, have been improved in the most cases for all monomer concentrations or absorbeddoses. Using polyester there ...
Depth dose distributions for protons in the energy range from 2 to 600 MeV have been calculated by Monte Carlo and analytical methods. The dependence on energy of Maximum Dose Equivalent (MDE), quality factor and isotropic factor recommended for practical use are presented. The problems connected with regulation of maximum permissible proton fluxes are discussed. (author).
BackgroundThe aim of this study was to compare and to validate different dose calculation algorithms for the use in radiation therapy of small lung lesions and to optimize the treatment...Full Text Available
Building on the concepts of MIRD methods described by Webber, Watson and others at this Symposium on the Dosimetry of Administered Radionuclides, we will now consider how to apply these principles to several experimentally based open-quote macroclose quotes and multicellular models. Specifically, methods to calculate absorbeddose using different types of particulate emission (alpha, beta) with a variety of antibody carriers (IgG, F(ab')_2, Fab) for radioimmunotherapy (RIT) will be reviewed. Additionally, a discussion of direct measurement methods at the multicellular level will reveal the problems of tumor absorbeddose heterogeneity when applied to animal and clinical studies.
A simple dose-saving procedure for the diagnosis of congenital hip dysplasia employing a diaphragm in nearfocus position is presented. Doses to the skin and the gonads were measured with a phantom for the new and other techniques. With optimal techniques the skin dose is smaller than 2 mR and the gonadal doses lie around 0.1 mR for both male and female patients. An estimate of the dose burden from undesired radiation is appended. (orig.).
Voxel-based prescriptions of deliberately non-uniform dose distributions based on molecular imaging, so-called dose painting or theragnostic radiation therapy, require specification of a transformation...Full Text Available
Objective: To investigate the relationship between exposure dose and image quality for a direct digital radiography system and to determine the optimum exposure parameters for pelvic examination. Methods: A contrast-detail phantom CDRAD2.0 was exposed to different doses and the IQF of phantom images were calculated. The optimum exposure parameters were determined by ANOVA and SNK analysis. The image of an anthropomorphic phantom taken with optimized exposure parameters was verified using CEC image criteria. Results: The IQF of the images of CDRAD2.0 phantom was significantly different for different doses, as the exposure dose was greater than 0.61 mGy. The IQFs have no difference for different dose groups. The image quality between this optimized exposure dose and conventional exposure dose not was ...
In everyday radiotherapy we must carry out the determination of absorbeddose measurement according to JARP's protocol. We explained an outline of JARP's 1974 and 1986 protocol in electron beam therapy, and mentioned it about the matter that should examined. To use it easily in clinic, a simplified procedure based on precisely to JARP's 1986 protocol is practical, the character of this procedure settles briefly the determination of mean incident energy of electron beams and get ready to table of ionization to absorbeddose conversion factor for various ionization chamber. Also, this procedure almost not influence on the accuracy of determination. We described systematically practical procedure for requisite absorbeddose calculation in a patient in electron beam therapy. (author).
The performance of PAN-based composite absorbers was evaluated in dynamic experiments at flow rates ranging from 25--100 bed volumes (BV) per hour. Composite absorbers with active components of ammonium molybdophosphate (AMP) PAN and K-Co ferrocyanide (KCoFC) PAN were used for separating Cs from a 1 M HNO{sub 3} + 1 M NaNO{sub 3} + 2 {times} 10{sup {minus}5} M CsCl acidic simulant solution. KCoFC-PAN and two other FC-based composite absorbers were tested for separating Cs from alkaline simulant solutions containing 0.01 M to 1 M NaOH and 1 M NaNO{sub 3} + x {times} 10{sup {minus}4} M CsCl. The efficiency of the Cs sorption on the AMP-PAN absorber from acidic simulant solutions was negatively influenced by the dissolution of the AMP active component. At flow rates of 50 BV/hr, the decontamination factor of about 10{sup 3} could be maintained for treatment of 380 BV of the feed. With the KCoFC-PAN ...
The study compares the dosesabsorbed by the dentomaxillary area in spiral CT and panoramic examinations. The dose measurements demonstrate that patients receive smaller doses with panoramic radiography than with spiral CT with Dentascan. After following for some variations from instrumental differences, they are in substantial agreement with literature data. Further investigations are needed considering the radiobiological risk related to the growing spread of Dentascan examinations.
The purpose of this study is to evaluate the accuracy of dose calculations by three algorithms. Depth dose, OPF (Output Factor) and dose profiles were measured in a heterogeneous phantom. These values were also calculated by three algorithms of the Batho power law (BPL), Equivalent-Tissue Air Ratio (ETAR) and Convolution superposition (CS). The data were obtained for 4, 6 and 10 MV photon beams with a linear accelerator (Varian 21EX). Field size ranged from 3 x 3 cm"2 to 10 x 10 cm"2. Dose profiles of beam penumbra were also measured by a 0.125 ml ionization chamber at the point of 8, 13 and 18 cm from the surface of the phantom at intervals of 1 mm. Differences between measured and calculated depth doses were within 2% in BPL and CS, but depth doses were overestimated in ETAR. OPFs were also overestimated with the error of more than 4% in ETAR. ...
By applying the linear-dose effect relation, the weighting factors for total risks recommended by IRCP can be transformed to weighting factors for somatic effects. Another weighting factor Msub(s) has to be used which takes into account the dependence of the latent period for occurrence of malignant disease and the variation of the incidence with time. On this basis a somatically significant dose equivalent can be defined as 'the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by the various individuals', and an approximation has been derived for this. Tables are presented of the somatic effective dose equivalents calculated for different x-ray examinations for various organs and tissues. The S.E.D. equivalents have also been calculated for ...
A calculation method of the X-ray radiation dose (energy of gamma- radiation remains in the range of energies where the mechanism of photoelectric absorption is the prevailing one) absorbed in the absorbers of final thickness is suggested. Calculations of resorption of secondary radiation (characteristic fluorescences) in the substance and kinetic energy of photoelectrons caused by this resorption (it would be enough to consider one or two hard series) are presented. Calculation of the spectrum of photoelectron energy yield in TeInSe_2 monocrystal for 0.1-0.5 A range of X-ray radiation is conducted by the developed methods.
A doubly Q-switched laser with both an acousto-optic (AO) modulator and a GaAs saturable absorber can obtain a more symmetric and shorter pulse with high pulse peak power, which has been experimentally proved. The key parameters of an optimally coupled doubly Q-switched laser with both an AO modulator and a GaAs saturable absorber are determined, and a group of general curves are generated for what we believe is the first time, when the single-photon absorption (SPA) and two-photon absorption (TPA) processes of GaAs are combined, and the Gaussian spatial distributions of the intracavity photon density and the initial population-inversion density as well as the influence of the AO Q-switch are considered. These key parameters include the optimal normalized coupling parameter, the optimal normalized GaAs saturable absorber parameters, and the normalized parameters ...
Tert-Butanol is an important intermediate in industrial chemical synthesis, particularly of fuel oxygenates. Human exposure to tert-butanol may occur following fuel oxygenate metabolism or biodegradation. It is poorly absorbed through skin, but is rapidly absorbed upon inhalation or ingestion and distributed to tissues throughout the body. Elimination from blood is slower and the half-life increases with dose. It is largely metabolised by oxidation via 2-methyl-1,2-propanediol to 2-hydroxyisobutyrate, the dominant urinary metabolites. Conjugations also occur and acetone may be found in urine at high doses. The single-dose systemic toxicity of tert-butanol is low, but it is irritant to skin and eyes; high oral doses produce ataxia and hypoactivity and repeated exposure can induce dependence...
Ionizing radiations that differ in number, size, and distribution of energy deposition events might be expected to cause different effects for the same absorbeddose. Furthermore, microdosimetry calculations suggest that large variations in biological effectiveness might be expected for internally deposited alpha-emitting radionuclides for the same absorbeddose, depending upon the specific activity and spatial distribution of the sources in tissue. The study described in this article was designed to demonstrate these phenomena in vitro. Cultured Chinese hamster ovary (CHO-K1 BH4) cells were exposed in vitro to inert, insoluble ceramic microspheres in zirconium dioxide labeled with "2"3"9Pu. The average exit energy of the 5.15 MeV alpha particle was calculated to be 4.3 MeV. Exposure times varied from four to seven hours to achieve the desired dose level.
International standards and guidelines for calibrating high-dose dosimetry systems to be used in industrial radiation processing recommend that dose-rate effects on dosimeters be evaluated under conditions of use. This is important when the irradiation relies on high-current electron accelerators, which usually provide very high dose-rates. However, most dosimeter calibration facilities use low-intensity gamma radiation or low-current electron accelerators, which deliver comparatively low dose-rates. Because of issues of thermal conductivity and response, portable calorimeters cannot be practically used with high-current accelerators, where product conveyor speeds under an electron beam can exceed several meters per second and the calorimeter is not suitable for use with product handling systems. As an alternative, Monte Carlo calculations can give theoretical estimates of the ...
Carcinogenesis is now generally recognized to be an important detrimental effect in man after low dose irradiation. The carcinogenic action of ionizing radiation is clearly demonstrated after exposure to relatively high doses (in excess of 0.5 Gy) but for lower dose levels reliable direct observations are not available. With the introduction of special protocols for the performance of large scale screening programs by mammography the average absorbeddose in glandular tissue in the average breast can be restricted to a value of 3 mGy per mammogram. The risk for tumor induction after exposure to these low doses can never be established from human epidemiology. In order to investigate the risk of repeated exposure to small dose of ionizing radiation the induction of mammary tumors has been investigated in rats of the WAG/Rij strain after ...
It needs accurate estimation of radiation level for verifying machinery and cable in Nuclear Power Plant. Therefore, in this study, we used ESR(Electron Spin Resonance) system for estimate dose of Alanine dosimeter. Alanine/ESR dosimetry, already known as a dosimetric method in medical and industrial field, was applied to estimate dose quantity at cable locations within a nuclear power plant as a part of equipment qualification program. Alanine/ESR dosimetry of absorbeddose range is 1 - 100 KGy. The alanine dosimeter is not significantly affected by temperature and fading is limited to 1% per year. The alanine dosimeters were fixed on the targeted cable or nearest position to measure dose quantity to get accurate value. Alanine dosimeters were scanned by commercially used two different ESR systems, e-scan and EMX series for alanine dosimeters. To estimate more accurate ...
Fins serve as heat transfer augmentation features in solar air heaters; however, they increase pressure drop in flow channels. Pin fins are relatively good heat transfer augmentation features with superior aerodynamic performance, and as a result find application in some solar air heaters. The exergy optimization method is employed in sizing the pin fin. Results indicate that high efficiency of the optimized fin improves the heat absorption and dissipation potential of a solar air heater. With optimum fin efficiency and superior absorptive coating quality, useful energy losses can be minimized. Some important observations pertinent in design are made. (author)
After fluid resuscitation, vasoactive drug treatment represents the major cornerstone for correcting any major impairment of the circulation. However, debate still rages as to the choice of agent, dose,...Full Text Available
IntroductionThe optimal dialysis dose for the treatment of acute kidney injury (AKI) is controversial. We sought to evaluate the relationship between renal replacement therapy (RRT)...Full Text Available
The decree refers to conditions of irradiation of food and its components for radappertization and radurization using gamma radiation from cobalt 60 or cesium 137, X radiation or electron beam up to maximum total medium absorbeddose 10 kGy.
A method for calculation of absorbeddose distributions in three dimensions for 1-20 MeV photons is presented. The method uses convolution/superposition of photon fluence distributions with energy scattering kernels. Results for Co-60 and X-ray beams in homogeneous and inhomogeneous media are compared with measurements. Good agreement is found between calculations and measurements. 8 refs.; 3 figs.
The distribution of the central benzodiazepine receptor specific ligand iodine-123 iomazenil was investigated in seven human adults from whole-body scans, blood samples and urine collected up to 24 h after injection. Using 12 source organs, the MIRD method was applied to calculate the absorbed radiation dose of the radioligand in various organs. The urinary bladder wall (0.15 mGy/MBq), lower large intestinal wall (0.071 mGy/MBq) testes (0.044 mGy/MBq) and upper large intestined wall (0.038 mGy/MBq) received the highest absorbeddoses. The average effective dose equivalent of "1"2"3I-IBZM for adults was estimated to be 0.033 mSv/MBq. (orig.).
This article proposes a model for estimating the effect of the overall thermal resistance of the absorber and the coolant on a solar thermal energy system utilizing advanced heat transfer mediums. Two equations can be used to model a dynamic system: one for the maximum conversion efficiency and one to specify the constraint that, in quasi-steady state, the net energy collected must be transferred to the coolant. These two equations define a constrained optimization problem in two variables, the fluid and the absorber temperatures. The results present interesting implications for liquid metal, direct absorption, and solar evaporating systems.
Forced harmonic vibration of a non-uniform elastic beam with attached dynamic vibration absorbers (DVA) is studied. Analytical approximation of the solution is obtained by the functional perturbation method (FPM). The problem has application to cutting tools operations where the resistance of the tool holder against regenerative chatter can be enhanced by optimizing the real part of the frequency response function (FRF). A test case of a beam with step-like heterogeneity and single DVA at the tip shows that the FPM solution is very accurate for up to ?40 percent deviation in both stiffness and mass density. Using the analytical results and Sims approach, optimal DVA tuning is found for each set of beam heterogeneity parameters by solving a set of nonlinear algebraic equations numer...
Radiation protection of the personnel who will perform interventions in the LHC Beam Cleaning Insertions is mandatory and includes the design of equipment and the establishment of work procedures. Residual dose rates due to activated equipment are expected to reach significant values such that any maintenance has to be planned and optimized in advance. Three-dimensional maps of dose equivalent rates at different cooling times after operation of the LHC have been calculated with FLUKA. The simulations are based on an explicit calculation of induced radioactivity and of the transport of the radiation from the radioactive decay. The paper summarizes the results for the Beam Cleaning Insertions and discusses the estimation of individual and collective doses received by personnel during critical interventions, such as the exchange of a collimator or the installation of Phase 2. The given examples outline the ...
In areas where radiation dose monitoring has not been performed, it is essential to use material available in the environment be able to rapidly assess doses to individuals for immediate emergency medical care or for general estimation of the radiological consequences. It was shown that certain types of telephone cards containing microchips have the potential to be used as individual radiation dosimeters in emergency situations to detect doses over 250 mGy by luminescence measurements. In order to understand the dosimetric properties of chip cards, the components obtained from INFINIEON Company at various stages of production were used for luminescence measurements. It is found that the protecting layer used above the chips so called 'globe top' is the main source of radiation induced signal in chip cards. The globe top produced by INFINIEON at that stage is found to contain SiO2 and Epoxy. In order to improve the ...
Thermoluminescence (TL) dosimetry was used to measure dose effects on the raw stock material of borosilicate container glass from different geographical locations. Effects were studied at times up to 60 days post-irradiation at doses from 0.15 to 20 Gy. The minimum detectable dose using this technique was estimated to be 0.15 Gy which is roughly equivalent to a 24 hr irradiation 1 cm from a 50 ng source of 60Co. Two peaks were identified in the TL glow curve, a relatively unstable peak around 125 C and a more stable peak around 225 C. Differences in TL glow curve shape and intensity were also observed for the glasses from different geographical origins. We investigate radiation induced defects in glass to further develop the technique of intrinsic dosimetry - the measurement of the total absorbeddose received by the walls of a container holding radioactive material. Intrinsic ...
Changing cream pearls into bluish-grey by #gamma# ray irradiation is a technique in coloring of pearls. Irradiated pearls are similar in color to cultured blue pearls. The pearl layers hardly change their color but the nuclei change into dark brown by irradiation. Visible light (500 - 700 nm) penetrating the pearl layer is absorbed by dark brown nucleus. The intensity of reflecting light between 400 and 500 nm at pearl surface, therefore, becomes stronger than that between 500 and 700 nm; therefore color of irradiated pearls look bluish-grey. The density of bluish-grey color increases with increasing absorbeddoses, but their luster at surface diminishes owing to the deterioration of the pearl layer by prolonged irradiation; high doses irradiation should be avoided. Irradiated pearls show no substantial fading of their color in a year and the rate of the fading is found to be lower than that for ...
To date, no single passive detector has been found that measures dose equivalent from ionizing radiation exposure in low-Earth orbit. We have developed the I.S.S. Passive Dosimetry System (P.D.S.), utilizing a combination of TLD in the form of the self-contained Pille TLD system and stacks of CR-39 plastic nuclear track detector (P.N.T.D.) oriented in three mutually orthogonal directions, to measure total dose and dose equivalent aboard the International Space Station (I.S.S.). The Pille TLD system, consisting on an on board reader and a large number of Ca{sub 2}SO{sub 4}:Dy TLD cells, is used to measure absorbeddose. The Pille TLD cells are read out and annealed by the I.S.S. crew on orbit, such that dose information for any time period or condition, e.g. for E.V.A. or following a solar particle event, is immediately available. Near-tissue equivalent CR-39 ...
A thermoluminescence (TL) sheet and its spatial readout system for in vivo measurement of spatial dose distribution around sources has been newly developed for intracavitary high dose-rate radiation therapy. The TL sheet (40 cm x 50 cm x 200 {mu}m), which is composed of teflon mixed with BaSO{sub 4} (Eu doped) powder, has a linear response with a very wide dynamic range from at least 0.002 cGy to 5000 cGy for {sup 60}Co sources. Phantom test of the TL sheet readout system demonstrated that absorbeddose with TL sheet and that with ionization chamber as standard dosimeter agreed well. For clinical application, TL sheet was attached on an applicator of intracavitary radiation therapy for rectal cancer. After irradiation with high dose-rate {sup 60}Co sources, the in vivo dose distribution on the surface of the rectum was determined. The TL sheet was suggested to ...
Techniques for reducing computation time in 3D photon dose calculations are addressed with specific emphasis given to the convolution/superposition approach. A single polyenergetic superposition model calculating absorbeddose per incident photon fluence (Gy cm"2) was developed in terms of TERMA and a total energy deposition kernel (a total point spread function). A novel approach was devised for reducing calculation time. The method, named the CF method, was based on the use of a conventional, fast model (here a modified power-law method was used) for the generation of 3D dose distributions on a fine dose matrix. Superposition calculations were carried out on a coarse matrix and calculation speed was increased simply by reducing the number of calculations. A set of correction factors was derived on the coarse grid from the ratio of the dose values from ...
This paper introduces an occupational exposure information system in detail, which is developed and in operation presently by Daya Bay nuclear power plant. It is presented in the paper that individual dose monitoring items and method, design and classification of database configuration, statistics and analysis of individual dose, and management of staff entering and exiting controlled area. The system is instructive to analysing individual dose and optimizing radiation protection measures. (authors)
Purpose: Various published reports involving intensity-modulated radiotherapy (IMRT) plans developed using automated optimization (inverse planning) have demonstrated highly conformal plans. These reported conformal IMRT plans involve significant target dose inhomogeneity, including both overdosage and underdosage within the target volume. In this study, we demonstrate the development of optimized beamlet IMRT plans that satisfy rigorous dose homogeneity requirements for all target volumes (e.g., #+-#5%), while also sparing the parotids and other normal structures. Methods and Materials: The treatment plans of 15 patients with oropharyngeal cancer who were previously treated with forward-planned multisegmental IMRT were planned again using an automated optimization system developed in-house. The optimization system allows for variable sized beamlets computed ...
Epiphyseal plates of growing bones are sensitive to ionizing radiation and this poses problems for the paediatric radiotherapist. In this case report we describe a child in whom electron beam therapy to the groin delivered only low dose radiation to the proximal hip epiphyses - 130 cGy fractionated over 5 weeks - but who suffered late maldevelopment. We explore the success of various radiotherapy techniques in minimizing the dose to the hip epiphyses in four other children. The appropriate positioning of the limb, the choice of treatment modality and, where possible, individual shielding blocks are considered and their effect on the dose to the hip estimated. Absorbeddoses of radiation delivered to the midpoint of the proximal femoral epiphyses have been retrospectively determined. (author).
The importance of cellular dosimetry in both diagnostic and therapeutic nuclear medicine is becoming increasingly recognized. Experimental range-energy relations for electrons and alpha particles, along with derived geometric reduction factors, are used to calculate cellular absorbed fractions for these radiations. The resulting absorbed fractions are employed to calculate cellular S-values for several radionuclides. Cellular absorbed fractions for monoenergetic electron sources with energies ranging from 0.1 keV to 1 MeV, distributed uniformly in the source region, are calculated for several target {l_arrow} source combinations including cell{l_arrow}cell, cell{l_arrow}cell surface, nucleus{l_arrow}nucleus, nucleus {l_arrow}cytoplasm and nucleus {l_arrow}cell surface. Similar data are also provided for monoenergetic alpha particle sources with energies ranging from 3 to 10 MeV. S-values are also conveniently tabulated for ...
The suitability of calcium silicate bricks (CSBs) for the retrospective measurement of gamma dose using luminescence techniques has been investigated. Bricks of this type are distinguished from fired clay bricks by containing negligible clay and requiring comparatively low temperature treatment during manufacture. They have been used widely in the construction f buildings in the Former Soviet Union since the 1970s but hitherto have not been used for retrospective dosimetry measurements. A procedure based on the se of the 210 deg. C thermoluminescence (TL) peak of quartz was tested with granular quartz extracted from three types of CSB, one of which had been taken from a settlement downwind of Chernobyl. The degree to which the residual geological TL signal within the temperature range of the 210 deg. C L peak had been reduced during manufacture varied with brick type; the levels of residual TL corresponded, in the samples tested, to absorbed ...
Radon concentration measurements were carried out using solid-state nuclear track-etch detectors (SSNTDs) type CA 80-15 cellulose nitrate films, in a Pleistocenic cave at Petralona, in Halkidiki, Northern Greece, at 55 km from the city of Thessaloniki. Radon levels as high as 88 kBqxm"-"3 (2.38 nCi x l"-"1) have been recorded inside the cave equivalent to 11.90 WL in terms of occupational exposure to radon and its decay products. Absorbeddose rates were performed using TL dosimeters, type TLD-200 (CaF_2-Dy) in a continuous monitoring program (integrated measurements). Dose rate levels as high as 110 nGy x h"-"1 were recorded inside the cave. In interpreting the high levels of radiation doses, radioactivity measurements regarding the naturally occurring "2"3"8U, "2"3"2Th and "4"0K radionuclides were carried out in various speleothems found at different sites in the cave. (author)
CT-Expo is a novel MS Excel application for assessing the radiation doses delivered to patients undergoing CT examinations, based on computational methods that were used to analyze the data collected in the German survey on CT practice in 1999. The program enables the calculation of all dose quantities of practical value, such as axial dose free-in-air, weighted CTDI, dose-length product, effective dose and uterine dose. In contrast to existing programs for CT dose assessment, CT-Expo offers a number of unique features, such as gender-specific dose calculation for all age groups (adults, children, newborns), applicability to all existing scanner models including correction of scanner-specific influences, and the possibility of comparison with the results from the German CT survey on CT practice. Three different ...
Simulations and experiments have been carried out to explore using a plastic scintillator as a dosimetry probe in the vicinity of a pulsed bremsstrahlung source in the range 4 to 20 MeV. Taking advantage of the tissue-equivalent properties of this detector in conjunction with the use of a fast digital signal processor near real-time dosimetry was shown to be possible. The importance of accounting for a broad energy electron beam in bremsstrahlung production, and photon scattering and build-up, in correctly interpreting dosimetry results at long stand-off distances is highlighted by comparing real world experiments with ideal geometry simulations. Close agreement was found between absorbed energy calculations based upon spectroscopic techniques and calculations based upon signal integration, showing a ratio between 10 MeV absorbeddose to 12 MeV absorbeddose of 0.66 at a distance of ...
Methylmethacrylate polymerisation in the presence of 4 wt% butadiene-acrylonitrile rubber was carried out at fixed dose-rate and temperature. The effect of irradiation was investigated with respect to the mechanical and dynamic-mechanical properties in the solid state. A general increase of the 'compatibilisation' on irradiation is obtained. In fact both rubber and polymethylmethacrylate glass transition temperatures, determined through dynamic-mechanical analysis, reveal the presence of strong interactions between the components. Furthermore an improvement of the mechanical tensile properties of the blends is observed when irradiation is continued after polymerisation, at least until a certain absorbeddose.
IMRT optimization requires a fast yet relatively accurate algorithm to calculate the iteration dose with small memory demand. In this paper, we present a dose calculation algorithm that approaches these goals. By decomposing the infinitesimal pencil beam (IPB) kernel into the central axis (CAX) component and lateral spread function (LSF) and taking the beam's eye view (BEV), we established a non-voxel and non-beamlet-based dose calculation formula. Both LSF and CAX are determined by a commissioning procedure using the collapsed-cone convolution/superposition (CCCS) method as the standard dose engine. The proposed dose calculation involves a 2D convolution of a fluence map with LSF followed by ray tracing based on the CAX lookup table with radiological distance and divergence correction, resulting in complexity of O(N"3) both spatially and temporally. This simple ...
The Monte Carlo transport codes LAHET and MCNP were used to calculate energy fluence spectra at three neutron therapy facilities. The results compare very favourably with measured data. Kerma spectra and the ratio of ICRU muscle tissue kerma to A-150 kerma, along the carbon to oxygen kerma ratio, were determined. Absorbeddose rate calculations are in reasonable agreement with measured values. Use of these codes to study modifications to existing therapy beams is briefly discussed. (author).
Application of an optimization technique to extract the non-ideal parameters of gas absorption with chemical reactions process was described. The gas absorption was modeled using mass transfer theory to represent the realistic behaviors of an absorber. The model was a highly non-linear iterative model which correlated the overall rate of absorption as the function of unknown non-ideal parameters, including the physical liquid mass transfer coefficient and the wetted interfacial area of of packings. The optimization program was developed to minimize the sum of squares of relative errors between the model predictions and the experimental data. Four sets of experimental data (case studies) with different operating conditions were used for extracting parameters. Comparisons between predicted and experimental measured overall absorption rate were in good agreement, average absolute value of relative errors not exceeding 5.4 %. ...
The Fresnel solar collector is a promising concept to reduce the electricity cost price in solar thermal power plants. The optical performance of a Fresnel collector depends on material properties, on its geometric layout and on the level of optical accuracy that can be obtained. A variety of geometric parameters, e.g. the height of the absorber, the number, size and distance of primary mirrors in.uence the shading and blocking of rays and the amount of rays missing the absorber. To evaluate the in.uence of the parameter variation regarding the electricity cost price and to yield an optimization, the optical performance is assessed with an annual simulation based on hourly weather-data. To permit a consideration of changes in collector cost according to different geometric layouts, cost factors where allocated to geometric parameters. The paper presents the method and the simulation results of the ...
High dose rate (HDR) brachytherapy for treating a cervix carcinoma has become popular, because it eliminates many of the problems associated with conventional brachytherapy. In order to improve the clinical effectiveness with HDR brachytherapy, a dose calculation algorithm, optimization procedures, and image registrations need to be verified by comparing the dose distributions from a planning computer and those from a humanoid phantom. In this study, the humanoid phantom was fabricated in order to verify the absolute doses and the relative dose distributions. The measured doses from the humanoid phantom were then compared with the treatment planning system for the dose verification. The humanoid phantom needs to be designed such that the dose distributions can be quantitatively evaluated ...
Since the beam width on the helical tomotherapy machine produced by TomoTherapy, Inc. is typically a few centimeters in the longitudinal direction (into the bore), the optimizer must choose...Full Text Available
Short-hairpin RNA (shRNA)–mediated gene knockdown is a powerful tool for targeted gene silencing and an emerging novel therapeutic strategy. Recent publications, however, reported unexpected...Full Text Available
Advanced modality of high-precision radiotherapy fulfilled by a composition of large numbers of small field beams called 'beamlets' can be achieved via nonuniform intensity fluencies. In case of radiation measurements and calculations with narrow high-energy photon beams, however, an accurate two-dimensional dosimetry is a challenging task due to dosimetrically unfavorable phenomena such as dramatic changes of the dose at the field boundaries, dis-equilibrium of the electrons resulting from larger detector volume, and non-uniformity between the detector and the phantom materials. Meanwhile, with the advantages of high spatial resolution and wide range of absorbeddoses, there is a growing demand of GAFCHROMICat..EBT film to confirm delivered dose distribution. Especially, the effects from the material differences between the phantom and the film can be minimized in the heterogeneous condition since the ...
The CyberKnife Robotic Radiosurgery System (Accuracy Incorporated, Sunnyvale, CA, USA) is used worldwide to treat tumors and neurological disorders anywhere in the body with sub-millimetre beam delivery accuracy. Accuracy has developed a number of new technologies in recent years to enhance the treatment of cancer patients. Such new technologies include a fast Monte Carlo Dose Calculation algorithm, Sequential Optimizationdose planning, the IrisTM Variable Aperture Collimator, an 800 MU/min Linear Accelerator, and Optimized Path Traversal. These technologies enable physicists and physicians to plan treatments quickly and easily and deliver them with unrivalled accuracy and precision
A first-order one-way wave system has been created based on characteristic analysis of the acoustic wave system and optimization of the dispersion relation. The authors demonstrate that this system is equivalent to a third-order scalar partial-differential equation which, for a homogeneous medium, reduces to a form similar to the 45{degree} paraxial wave equation. This system describes accurately waves propagating in a 2D heterogeneous medium at angles up to 75{degree}. The one-way wave system representing downgoing waves is used for a modified reverse time migration method. As a wavefield extrapolator in migration, the downgoing wave system propagates the reflection events backwards to their reflectors without scattering at the discontinuities in the velocity model. Hence, images with amplitudes proportional to reflectivity can be obtained from this migration technique. They present examples of the application of the new migration method to synthetic seismic data ...
Previously, an analytical dose calculation algorithm for MLC-based radiotherapy was developed and commissioned, which includes a detailed model of various MLC effects as a unique feature [1]. The algorithm was originally developed as an independent verification of the treatment planning system's dose calculation and it explicitly modeled spatial and depth dependent MLC effects such as interleaf transmission, the tongue-and-groove effect, rounded leaf ends, MLC scatter, beam hardening, and gradual MLC transmission fall-off with increasing off-axis distance. Originally the algorithm was implemented in Mathematica trademark (Wolfram). To speed up the calculation time and to be able to calculate high resolution 2D dose distributions within a reasonable time frame (<2 s) the algorithm needs to be optimized and to be embedded in a user friendly environment. To achieve this goal, the ...
Allogeneic stem-cell transplantation (SCT) is potentially curative therapy in AML by providing both dose-intensive chemo-radiotherapy and induction of graft-versus-leukemia (GvL) effect. Historically, more emphasis was given to the intensity of conditioning. Over the last decade the pendulum turned more towards induction of GvL as the primary goal. A plethora of non-myeloablative (NMA) and reduced-intensity conditioning regimens (RIC) were introduced trying to reduce transplant-related toxicities and allow SCT in elderly and medically infirm patients. In addition, reduced-toxicity myeloablative regimens (RTC) based on fludarabine and myeloablative alkylating-agent doses were designed to allow safer administration of dose-intensive therapy. Conditioning dose-intensity is highly correlated w...
Several short-lived, high-energy beta emitters are being proposed as the radionuclide components for molecular-targeted potential cancer therapeutic agents. The laboratory mice used to determine the efficacy of these new agents have organs that are relatively small compared to the ranges of these high-energy particles. The dosimetry model developed by Hui et al. was extended to provide realistic beta-dose estimates for organs in mice that received therapeutic radiopharmaceuticals containing 90Y, 188Re, 166Ho, 149Pm, 64Cu, and 177 Lu. Major organs in this model included the liver, spleen, kidneys, lungs, heart, stomach, small and large bowel, thyroid, pancreas, bone, marrow, carcass, and a 0.025-g tumor. The study as reported in this paper verifies their results for 90Y and extends them by using their organ geometry factors combined with newly calculated organ self-absorbed fractions from PEREGRINE and MCNP. PEREGRINE and MCNP agree to within 8% ...
In neutron radiography, as in other forms of NDE, it is sometimes desirable to observe dynamic events. This need has generated increased interest in the development of real-time neutron radiography systems and neutron-to-light converter screens optimized for real-time application. Two screens currently available at MURR are: (1) a 0.041-cm-thick Gd_2O_2S screen manufactured by 3M Company and (2) a "6KiF-ZnS(Ag) screen (NE 426) manufactured by Nuclear Enterprises. These screens are presently used in conventional film neutron radiography and represent two of the commercially available screens that have demonstrated the greatest resolution and sensitivity. Unfortunately, these screens have severe limitations when used for real-time neutron radiography. In order to isolate and minimize the factors contributing to these limitations, several neutron absorbers and phosphorus were studied at MURR. The screen thickness and the neutron ...
For the purpose of risk estimates from radiation carcinogenesis including leukemogenesis and radiation genetic effects, the biological significant dose is not the tissue kerma in air but the absorbeddose in organ or tissue with respect to carcinogenic and leukemogenic effects or genetic effects. In order to estimate organ or tissue dose from the tissue kerma in air, a ratio of the organ or tissue dose to the tissue kerma in air for survivors in Hiroshima and Nagasaki was calculated with the aid of the Snyder's mathematical phantoms constructed so as to simulate the body shape of survivors aged 5, 10 years old and adult at the time of atomic bomb detonations. The ratios were corrected for the angular distribution of atomic bomb radiations, assuming an anisotropic angular distribution for the survivors exposed to the atomic bombs in open air and the isotropic distribution for the ...
Following the publication (Stenhouse and Baxter, Nature; 267:828 (1977)) of the levels of bomb "1"4C and the residence times of carbon in the human body, excess radiation burdens from this radioisotope are evaluated under the assumption that no radiation dose, however small, can be regarded as entirely harmless biologically. The estimated annual absorbeddose attributable to "1"4C both natural and man-made for 1953-1973 and similar predicted figures for 1975-2025 are shown graphically. The cumulated doses to gonads (over 30 yr) and to bone marrow and bone-lining cells (over 60 yr) and also estimates of the biological damage to reproductive cells from "1"4C #beta#-irradiation (30 yr accumulated dose) are presented. It is concluded from both genetic and somatic considerations, that the potential human radiation burden due to artificially produced "1"4C calculated using the assumptions ...
Purpose: This study presents a dosimetric optimization effort aiming to compare intensity-modulated (IM) X-rays and IM protons in 4 different orbital and paraorbital tumors. These are most challenging targets for standard radiotherapy due to their close relationship with the eyes and related structures. Methods and Materials: A primary orbital lymphoma, an optic nerve meningioma, a sphenoidal ridge meningioma protruding into the orbit, and a pediatric parameningeal paraorbital rhabdomyosarcoma were selected for the purpose of this study. Planning target volumes (PTVs) and organs at risk (OAR) were defined in each patient CT data set for each tumor site. IM X-ray and IM proton three-dimensional treatment plans were implemented. The following total tumor doses were prescribed: 30 Gy for the orbital lymphoma, 54 Gy for both meningiomas, and 50.4 Gy for the rhabdomyosarcoma case. Dose-volume histograms (DVHs) were obtained for ...
Objective: To characterize the protocols with low-dose radiation in survey CT scans for localization. Methods: Eighty standard adult patients, head and body phantoms were recruited. Default protocols provided by operator's manual setting were that all the tube voltage for head, chest, abdomen and lumbar was 120 kV; the tube currents were 20,10,20 and 40 mA, respectively. Values of kV and mA in the low-dose experiments were optimized according to the device options. For chest and abdomen, the tube position were compared between default (0 degree) and 180 degree. Phantoms were scanned with above protocols, and the radiation doses were measured respectively. Paired t-test were used for comparisons of standard deviation in CT value, noise and exposure surface dose (ESD) between group with default protocols and group with optimized protocols. Results: The ...
The regenerative-chatter resistance of a viscoelastic cantilever beam is analyzed and compared to the common dynamic vibration absorber (DVA) system. The beam represents a tool holder for turning operation in machining. The optimum structural parameters are found by maximizing the most negative real part of the frequency response function (FRF). The FRF is found analytically by using an appropriate Greens function. Keeping the cantilever static stiffness constant, further increase in the optimal resistance is achieved by changing the ratio between the two elastic moduli in the 3-parameter solid viscoelastic material model. Three additional chatter resistance indicators are also investigated: the most positive real part of the FRF, the magnitude of the FRF and the resonant frequency. It is ...
Faced with increasing indications for the use of iodine-131 labelled lipiodol in the treatment of hepatocellular carcinoma (HCC), it appears essential to develop an individualized dosimetrY so we can predict the potential effectiveness of this treatment and adjust the activity to be injected. We developed a dosimetric protocol based on imagery and dedicated to calculation of the tumoral dose during the treatment of hepatocellular carcinoma by iodine-131 labelled lipiodol. This concept was developed on a SPECT- CT gantry, and integrates corrections for the phenomena of attenuation, diffusion and dead time. The dose is calculated according to the formalism proposed by the Medical Internal Radiation Dose Committee (MIRD). This protocol was applied to a series of 41 patients in the framework of a retrospective study. The results obtained in terms of biodistribution are compatible with previously published data. The total ...
Adenosine triphosphate (ATP) is an alternative to dipyridamole or adenosine in thallium-201 myocardial scintigraphy. However, the optimaldose of ATP has not been determined. A Doppler guide wire study showed the coronary flow velocity at a dose of 0.15 mg/kg of ATP was equal or higher than that at 0.14 mg/kg of adenosine or 0.56 mg/kg of dipyridamole. ATP was given intravenously to 67 patients with coronary artery disease at 0.15 mg/kg/min for 6 min. Thallium-201 was injected at 3 min, followed by immediate and delayed (3 hrs) tomographic imaging. There was no serious side effect during examination, although chest pain (26%), dyspnea (17%), and flushing (33%) were common. The sensitivity and specificity to detect coronary artery disease were 98 and 100%, respectively. The sensitivity to detect left anterior descending artery, left circumflex artery, and right coronary artery lesions was 94, 59 and 77%, respectively. ATP ...
An important unresolved issue in outcomes analysis for lung complications is the effect of poor or completely lacking heterogeneity corrections in previously archived treatment plans. To estimate this effect, we developed a novel method based on Monte Carlo (MC) dose calculations which can be applied retrospectively to RTOG/AAPM-style archived treatment plans (ATP). We applied this method to 218 archived nonsmall cell lung cancer lung treatment plans that were originally calculated either without heterogeneity corrections or with primitive corrections. To retrospectively specify beam weights and wedges, beams were broken into Monte Carlo-generated beamlets, simulated using the VMC++ code, and mathematical optimization was used to match the archived water-based dose distributions. The derived beam weights (and any wedge effects) were then applied to Monte Carlo beamlets regenerated based on the patient computed tomography ...
A new leaf-sequencing approach has been developed that is designed to reduce the number of required beam segments for step-and-shoot intensity modulated radiation therapy (IMRT). This approach to leaf sequencing is called continuous-intensity-map-optimization (CIMO). Using a simulated annealing algorithm, CIMO seeks to minimize differences between the optimized and sequenced intensity maps. Two distinguishing features of the CIMO algorithm are (1) CIMO does not require that each optimized intensity map be clustered into discrete levels and (2) CIMO is not rule-based but rather simultaneously optimizes both the aperture shapes and weights. To test the CIMO algorithm, ten IMRT patient cases were selected (four head-and-neck, two pancreas, two prostate, one brain, and one pelvis). For each case, the optimized intensity maps were extracted from the Pinnacle"3 treatment planning system. ...
We have studied the application of direct aperture optimization (DAO) as an inverse planning tool for breast IMRT. Additionally, we have analysed the impact of respiratory motion on the quality of the delivered dose distribution. From this analysis, we have developed guidelines for balancing the desire for a high-quality optimized plan with the need to create a plan that will not degrade significantly in the presence of respiratory motion. For a DAO optimized breast IMRT plan, the tangential fields incorporate a flash field to cover the range of respiratory motion. The inverse planning algorithm then optimizes the shapes and weights of additional segments that are delivered in combination with the open fields. IMRT plans were generated using DAO with the relative weights of the open segments varied from 0% to 95%. To assess the impact of breathing motion, the ...
Graft copolymerization of sodium styrene sulfonate (SSS) onto electron beam (EB) irradiated poly(vinylidene fluoride) (PVDF) films was investigated to find out a simple preparation process for sulfonic acid proton exchange membranes with respect to monomer concentration, absorbeddose, temperature, film thickness and storage time. The reaction order of the monomer concentration and absorbeddose of grafting was found to be 2.84 and 1.20, respectively. The overall activation energy for graft copolymerization reaction was calculated to be 11.36 kJ/mol. The initial rate of grafting was found to decrease with an increase in the film thickness. The trapped radicals in the irradiated PVDF films remained effective in initiating the reaction without considerable loss in grafting level up to 180 days, when stored under -60 {sup o}C. The presence and distribution of polystyrene sulfonate grafts in the obtained ...
The 9.50 GHz electron paramagnetic resonance (EPR) spectra of unirradiated and "6"0Co #gamma#-ray irradiated cardamom (Elettaria cardamomum L. Maton, Zingiberaceae), ginger ((Zingiber officinale Rosc., Zingiberaceae), and saffron (Crocus sativus L., Iridaceae) have been investigated at room temperature. All unirradiated spices presented a weak resonance line with g-factors around free-electron ones. After #gamma#-ray irradiation at an absorbeddose of up to 11.3 kGy, the presence of EPR spectra whose amplitude increase monotonously with the absorbeddose has been noticed with all spices. A 100 "oC isothermal annealing of 11.3 kGy irradiated samples has shown a differential reduction of amplitude of various components that compose initial spectra, but even after 3.6 h of thermal treatment, the remaining amplitude represents no less then 30% of the initial ones. The same peculiarities have been noticed ...
The X-band EPR spectra of unirradiated and "6"0 Co gamma ray irradiated cardamom (Elettaria cardamomum L. Maton, Zingiberaceae), ginger ((Zingiber officinale Rosc., Zingiberaceae), saffron (Crocus sativus L., Iridaceae), and curry have been investigated at room temperature. All unirradiated spices presented a weak resonance line with g-factors around free-electron ones, most probably due to the presence of semiquinones, previously reported to have paramagnetic properties. After gamma ray irradiation at absorbeddose up to 11.3 kGy we have noticed in all spices the presence of complex EPR spectra consisting of a superposition of at last two different paramagnetic species whose amplitude increase monotonously with the absorbeddose. A 100 deg. C isothermal annealing of 11.3 kGy irradiated samples has shown a differential reduction of amplitude of various components that form the initial spectra, but even ...
A number of procedures in diagnostic radiology and cardiology make use of long exposures to x-rays from fluoroscopy units. Although numerous studies have been performed to measure or calculate skin dose from these procedures, there have only been a handful of studies to determine the dose to the other organs. This thesis was focused on devising a method to calculate the absorbeddose to underlying tissues and organs. The work was performed in several stages. First, a commercial convolution/superposition-based treatment planning system used in radiation oncology was modified and complemented to make it usable with the low energies of x-rays used in diagnostic radiology. This required generation of energy deposition kernels in the kilovoltage energy range. The kernels were generated using the EGS4 Monte Carlo system of codes and added to the treatment planning system. The treatment planning system was ...
The dosimetry for radiotherapy involving neutrons is very complicated, owing to the complexity of secondary radiation components, whose contributions to the total absorbeddose have to be discriminated, owing to the different radiobiological effects. In order to separate thermal neutrons and photons, LiF dosimeters are mostly utilized. containing different percentage of Li, like as TLD-700, TLD-100 and TLD-600, but many problems arise. In the response of TLD-700 exposed to neutron-gamma mixed fields with high neutron flux, the contribution of thermal neutrons to the Tl emission is high. Moreover. TLD-100 and TLD-600 may undergo radiation damage, and great care has to be taken in order to obtain reliable results. Other TLDs showing lower sensitivity to neutrons are proposed and experimented for such high-flux neutron fields. The faced problems and various proposed solutions are here described. (Author)
The somatic and genetic radiation exposure of patients undergoing Digital Subtraction Angiography (DSA) and traditional Film Arteriography (FA) of cranial, cervical, thoracic and abdominal vascular territories are compared. The radiation dosesabsorbed within the critical organs - red bone marrow, lung, thyroid gland and female breast - and in the gonads were measured using an anthropomorphic Alderson phantom. A Somatic Dose Index was calculated in order to estimate the somatic radiation risk. The somatic radiation exposure depends upon the location of the critical organs with respect to the entrance site of the x-ray beam, and can be reduced by an appropriate choice of the angiographic projection. Under this condition, the radiation exposure of the patient during DSA can be lower than during FA. For renal DSA an a.p. projection, the use of an abdominal compression device and careful caudal shielding of the field are ...
The MCNPE-BO and MCNP4 Monte Carlo electron-photon codes were used to calculate the dose equivalent per unit fluence at various depths in tissue-equivalent slab phantoms for broad parallel beams of monoenergetic electrons with energies from 50 keV to 10 MeV. The study was carried out in the framework of the activities of a ICRP/ICRU Joint Task Group with the support of EURADOS WG4 (Numerical Dosimetry). Some preliminary results and comparisons as well as a general discussion on the performances of the codes are presented, demonstrating quite a satisfactory agreement among the results obtained using the two codes and those of other authors. (author).
Purpose To study the chemical modifications induced upon irradiation of solid human insulin at radiosterilization doses and investigate the influence of the absorbeddose on radiolysis. Materials and Methods Volatile radiolytic products were monitored by gas chromatography coupled with mass spectrometry (GC-MS) and non-volatile products by two different high performance liquid chromatography (HPLC) methods: the formation of higher molecular weight proteins was assessed by size exclusion liquid chromatography whereas assays for related compounds and chemical potency tests were carried out using reverse-phase HPLC-UV. Conformational changes were investigated by measurements of circular dichroism. Results After gamma irradiation at 10?kGy, the recovery of insulin was 96.8%; higher molecular w...
Although it has been established that lead is transferred in milk from mother to suckling offspring, the physiological processes and parameters involved are not well understood. Single i.v. doses (0.2 mg/kg) or p.o. doses (2 mg/kg) of radiolabeled lead were administered to lactating and nonlactating female mice, and lead concentrations in blood, plasma, and milk were determined during a 21-day period. Large differences in lead elimination were observed between lactating and nonlactation mice. A significant fraction (25%) of the initial maternal dose (absorbeddose) was transferred to the suckling pups. The ratio of lead concentration in milk to lead concentration in plasma was found to be nearly constant over time. However, the milk-to-blood concentration ratios decreased during the same period. Furthermore, the concentration of lead in milk exceeded the plasma concentration by a ...
BACKGROUND: Epinephrine injection is the most common endoscopic therapy for peptic ulcer bleeding. Controversy exists concerning the optimaldose of proton pump inhibitors (PPI) for patients with bleeding peptic ulcers after successful endoscopic therapy. The objective of this study was to determine the optimaldose of PPI after successful endoscopic epinephrine injection in patients with bleeding peptic ulcers. METHODS: A total of 200 peptic ulcer patients with active bleeding or nonbleeding visible vessels (NBVV) who had obtained initial hemostasis with endoscopic injection of epinephrine were randomized to receive omeprazole 40 mg infusion every 6 h, omeprazole 40 mg infusion every 12 h or cimetidine (CIM) 400 mg infusion every 12 h. Outcomes were checked at 14 days after enrollment. RE...
Conformal radiation therapy represents a considerable and attractive challenge in oncology. Its aim is mainly to improve local control by increasing the dose with an acceptable rate of complications. This work overviews the world literature on this subject. The technical and theoretical requirements are highlighted. These requirements include a precise definition of the target volume by digital imaging (essentially CT scan), but also clear view of the target volume and the organs at risk, a specific collimation of the beam, 3-D dose calculations, optimization procedures, and a rigid immobilization of the patient with verification of his position. Moreover, the clinical applications of conformal radiation therapy are reviewed and discussed. (authors). 80 refs., 1 tab.
For the purpose of optimizing the process of co-implantation of MeV Si ions to reduce boron transient enhanced diffusion and boron-enhanced diffusion in Si, multiple MeV implantations and annealing at different temperatures have been performed. A slight improvement on the suppression of B diffusion is observed by adding a low temperature annealing step after the MeV implantation. No differences in B diffusion are observed when the Si doses are increased from 1 x 10{sup 15} to 1 x 10{sup 16} cm{sup -2}. This dose independent behavior is speculated to be a quasi-steady state of vacancy cluster evaporation.
For the purpose of optimizing the process of co-implantation of MeV Si ions to reduce boron transient enhanced diffusion and boron-enhanced diffusion in Si, multiple MeV implantations and annealing at different temperatures have been performed. A slight improvement on the suppression of B diffusion is observed by adding a low temperature annealing step after the MeV implantation. No differences in B diffusion are observed when the Si doses are increased from 1 x 10"1"5 to 1 x 10"1"6 cm"-"2. This dose independent behavior is speculated to be a quasi-steady state of vacancy cluster evaporation.
Full text: Radiotherapy treatment planning (RTP) relies heavily on medical imaging. Until recently, the most important planning tool was the treatment simulator. The kilovoltage radiographic capabilities in a treatment simulator enabled the boundaries of treatment fields to be visualized with respect to bony anatomic landmarks. Perhaps the most important advance in treatment planning in recent years is the ability to visualize the passage of the beams with respect to a more accurate geometrical representation of the tumor and other soft tissue structures. This 'virtual simulation' uses a computer-based representation of a patient to determine the extent of the disease and the location of radiation sensitive normal tissue. Computer tomographic (CT) imaging produces a high-resolution three-dimensional representation of anatomy that can be correlated with other image sets such as magnetic resonance images (MRI) of function. Positron emission tomographic (PET) imaging is beginning to be ...
In this study, the biosorption of Cd(II), Ni(II) and Pb(II) on Aspergillus niger in a batch system was investigated, and optimal condition determined by means of central composite design (CCD) under response surface methodology (RSM). Biomass inactivated by heat and pretreated by alkali solution was used in the determination of optimal conditions. The effect of initial solution pH, biomass dose and initial ion concentration on the removal efficiency of metal ions by A. niger was optimized using a design of experiment (DOE) method. Experimental results indicated that the optimal conditions for biosorption were 5.22 g/L, 89.93 mg/L and 6.01 for biomass dose, initial ion concentration and solution pH, respectively. Enhancement of metal biosorption capacity of the dried biomass by pretreatment with sodium hydroxide was observed. Maximal removal efficiencies for ...
The main challenges for PMOS ultra shallow junction formation remain the transient enhanced diffusion (TED) and the solid solubility limit of boron in silicon. It has been demonstrated that low energy boron implantation and spike annealing are key in meeting the 90nm technology node ITRS requirements. To meet the 65nm technology requirements many studies have used fluorine co-implantation with boron and Si"+ or Ge"+ pre-amorphization (PAI) and spike annealing. Although using BF_2"+ can be attractive for its high throughput, self-amorphization and the presence of fluorine, many studies have shown that the fluorine successfully reduce TED, its energy needs to be well optimized with respect to the boron's, therefore BF_2"+ does not present the right fluorine/boron energy ratio for the optimum junction formation. In this work we optimize the fluorine energy for boron energies down to 200eV. We show the dependence of optimized ...
This study evaluates the effect of gamma radiation on the viability of fungi and actinomycetes that contaminate medicinal plants. The relationship between the total lipids of some fungi and actinomycetes and their sensitivity to gamma radiation is also investigated. The data reveal that the viable counts of these florae decrease approximately exponentially with the radiation dose, the effective dose for the elimination of these microorganisms being about 5 kGy for all the medicinal plants under study. Response of pure cultures of fungi and actinomycetes isolated from medicinal plants to increasing absorbeddoses of gamma radiation indicate that an increase in radioresistance is in the following order: Streptomyces rimosus, Fusarium solani, Nocardia kuroishii. F. oxysporum, A. fumigatus, A. flavus, A. parasiticus and A. ochraceus. The total lipid contents of molds and actinomycetes have been reported to ...
The study compares the dosesabsorbed by the dentomaxillary area in spiral CT and panoramic examinations. The dose measurements demonstrate that patients receive smaller doses with panoramic radiography than with spiral CT with Dentascan. After following for some variations from instrumental differences, they are in substantial agreement with literature data. Further investigations are needed considering the radiobiological risk related to the growing spread of Dentascan examinations. [Italian] Questo lavoro intende confrontare le dosi assorbite nel distretto dento-mascellare, con le due principali tecniche utilizzate in questo campo: TC spirale e ortopantomografia. Emerge come l'esame panoramico delle arcate dentarie eseguito con l'ortopantomografo comporti la'ssorbimento di dosi inferiori rispetto a quelle dell'esame TC spirale con programma Dentascan. Questi dati, ...
Dairy products doubly labeled with 45Ca and 47Ca were used to evaluate an extrinsic labeling procedure for calcium bioavailability determination. Nonfat milk, yogurt, and fresh cheese curd were prepared from caprine milk that was intrinsically labeled with 45Ca. The products were then labeled extrinsically with 47Ca and administered to rats by gavage. The 47Ca to 45Ca ratio in bone and teeth averaged about 1.00 with either milk, yogurt, or CaCl2, but the ratio was about 1.04 when dosed with cheese curd. Ca absorption, determined by whole-body counting of 47Ca, was lower (P less than 0.05) in cheese curd (59%) than in either milk (69%), yogurt (72%), or CaCl2 (72%). Expressed as percent of dose, the absorption of 47Ca was highly correlated with bone 47Ca (r = 0.973) and with bone 45Ca (r = 0.946). Correlation between tibia 47Ca and tibia 45Ca was r = 0.923. For the dairy products tested, our results indicated that extrinsic 47Ca was ...
Solar ultraviolet radiation is damaging for living organisms due to its high energy pro each photon. The UV radiation is often separated into three regions according to the wavelength: UVC (200-280 nm), UVB (280-320 nm) and UVA (320-400 nm). The most hazardous part, UVC is absorbed completely in the upper atmosphere by molecular oxygen. UVB radiation is absorbed by atmospheric ozone partly, and it is reaching Earth`s surface, as UVA radiation. Besides atmospheric ozone, very important factors in determining the intensity of UVB radiation globally are the solar zenith angle and cloudiness. It may be calculated from global ozone changes that the clear-sky UVB doses may have enhanced by 10-15 % during spring and 5-10 % during summer at the latitudes of Finland, following the decrease of total ozone between 1979-90. The Finnish ozone and UV monitoring activities have become a part of international activities, especially the EU ...
the cotton leaf worm, Spodoptera littoralis (boisd.) were irradiated with 100,150 and 200 Gy to induce inherited sterility. the effects of the tested doses applied to these pupae through three consequent fillial generations and the retarded influence on their F_1,F_2 and F_3 generations progeny were examined . irradiation of parental male induced damage to their daughter females ovaries. the overioles of females among P_1 ,F_1 and F_2 generations showed that the follicular epithelial cells appeared abnormal beside their limited separation from developing oocytes which became shrinked, semi absorbed or completely absorbed leaving vacuoles. the nurse cells were reduced or absent in some parts. damage was obvious through the first and second generations especially at 150 and 200 Gy. in the third generation, ovaries were not greatly affected
Magnetic particles (MAG*SEP"S"M) coated with various absorbents were evaluated for the separation and recovery of low concentrations of cesium from nuclear waste solutions. The MAG*SEP"S"M particles were coated with (1) clinoptilolite, (2) transylvanian volcanic tuff, (3) resorcinol formaldehyde, and (4) crystalline silico-titanate, and then were contacted with a Hanford supernatant simulant. Particles coated with the crystalline silico-titanate were identified by Bradtec as having the highest capacity for cesium removal under the conditions tested (variation of pH, ionic strength, cesium concentration, and absorbent/solution ratio). The MAG*SEP"S"M particles coated with resorcinol formaldehyde had high distribution ratios values and could also be used to remove cesium from Hanford supernant simulant. Gamma irradiation studies were performed on the MAG*SEP"S"M particles with a gamma dose equivalent to 100 cycles of use. ...
With the advent of intensity-modulated radiation therapy (IMRT), the inclusion of heterogeneity corrections is further complicated by the conformal delivery of many small beams forming steep dose gradients. Radiation treatment planning has evolved to take into account even small changes in tissue density so that the dose to tumor can be further optimized. However, different treatment planning systems incorporate different heterogeneity correction algorithms, and it is unclear whether any of these algorithms are superior to others in terms of accurately predicting delivered radiation doses relative to measurement in a clinical setting. The purpose of this study was to determine the accuracy of heterogeneity dose calculations from two widely used IMRT treatment planning systems (Pinnacle and Corvus) against measurement. These two systems handle heterogeneity dose ...
Research facilities and personnel in high efficiency separation processes for carbon dioxide removal from industrial sources, such as fossil fuel fired power stations, goal gasification plants, and hydrogen production units for enhanced oil recovery applications at the University of Regina were described. A brief summary of current projects, such as the determination of CO{sub 2} absorption capacity of sterically hindered amines, the formulation of high CO{sub 2} absorption capacity solvents, the search for high performance absorbers and regenerators, studies on material corrosion, and optimization and cost studies of co-production of CO{sub 2} and electricity, was also provided.
In order to maintain a safe operation and availability of generating facilities, qualitative and quantitative assessment of piping vibration was performed vibration sources and damages of piping support was identified on the second piping system of Wolsung nuclear power plant unit 1 .Inspected piping supports and structures in both hot and cold condition .Established evaluation procedures of piping vibration .Performed the static analysis of 2 nd piping system .Established optimal vibration reducing method .The measured vibration level after installing rigid supports and energy absorbing type restraint was reduced about 7 times in velocity unit (author). 24 refs., 95 figs.
A program was undertaken to radiation harden an existing power integrated circuit technology (BCDMOS) to total dose, gamma dot, SEU, and neutrons. Efforts have centered around hardening and optimizing our CMOS, DMOS, and NPN devices. Initial results indicate a substantial improvement in hardness over our existing commercial technology.
SGS-Thomson and CNES significantly hardened a power MOSFET transistor against heavy ions and cobalt 60 total dose. The influence of the major technological steps on the component radiation sensitivity has been analyzed. Then the optimization has been carried out, using booth computerized simulation and experimental data. (D.L.). 5 refs., 8 figs.
Topics of this proceedings are: DNA damage and repair; Space research; Cell and tissue radiobiology; Treatment planning 1: The role of clinical RBEs; Treatment planning 2: Doseoptimization and inverse planning; Dosimetry; Clinical results of particle therapy and new techniques; Status reports and future developments. Separate abstracts were prepared for 79 chapters. (orig./SR)
The fundamental recommendations of the ICRP issued in its publication of 1990 stipulate the general principle of performance of dose measurements at regular intervals in the field of diagnostic radiology, for the purpose of equipment performance checking and optimization of radiological protection. In response to this requirement, the Federal Ministry, in cooperation with experts and the competent supervising authorities, has issued an order to install dose-area-product meters in angiographic examination systems, imaging systems and fluoroscopic screen devices primarily used for examining infants and children up to the age of 12. This is done in response to reported cases of adverse effects of radiation exposure and the high priority given to radiological protection in the examination of infants and children. In 1992, an expert group was convened to discuss and elaborate instructions for including ...
Rectum reference dose points have a direct impact on the morbidity seen in gynecological intracavitaty radiotherapy. The aim of this study is to obtain less morbidity by marking rectum with radio opaque solution. Fourteen patients with gynecological cancer who underwent external radiotherapy received 15 Gray (Gy) intracavitary radiotherapy. During the internal radiotherapy planning, radio opaque solution has been administered into the rectum to observe it on lateral radiogram. Thus rectum reference dose point and five points were marked at sites nearest to the sources. Nucletron Planning system was used for obtaining three-dimensional planning. After therapy patients were followed at every three months. Median follow-up was 18 months. Most frequently observed morbidities were grade 1-2 rectitis and cystitis in six patients. As a result, more accurate rectum dose values and less factors causing dose ...
IMRT with inverse planning allows simultaneous integrated boost strategies that exploit the heterogeneous dose distribution within the planning target volumes (PTVs). In this scenario, the location of cold spots within the target becomes a crucial issue and has to be related to the distribution of the clonogenic cell density (CCD). The main aim of this work is to provide the means to calculate the optimal prescription dose in a relative inhomogeneous dose distribution. To achieve this, the prescription dose has to be assigned to obtain the same tumor control probability (TCP) as the ideal homogeneous distribution, taking into account different CCDs in different PTVs (i.e. visible and subclinical regions). An adapted formulation of the linear-quadratic model, within the F-factor formalism, has been derived to preserve a chosen TCP value for the whole target volume. The F-factor has ...
Full text: Optically stimulated luminescence (OSL) dating of individual sand-sized grains of quartz has advanced significantly over the past decade opening up new vistas in luminescence geochronology. Today, single-grain OSL dating can be used to constrain the burial ages of many deposits, including fluvial sediments, glaciofluvial material and archaeological sediments. It also provides a means of examining the stratigraphic integrity of archaeological sites where sediment mixing might have occurred. An OSL age is calculated by dividing the burial dose (the doseabsorbed by the grain since it was last exposed to sunlight) by the environmental dose rate (the rate of supply of ionizing radiation to the grain over the period of burial). To obtain reliable OSL ages, therefore, an accurate estimate of the dose rate is required for each sample. Here we describe our OSL dating campaign at ...
Apoptosis is a pattern of cell death involving nuclear pycnosis, cytoplasmic condensation, and karyorrhexis. Apoptosis induced by continuous irradiation with gamma rays (externally given by a 137Cs source) or with beta rays (from tritiated water injected ip) was quantified in the crypts of two portions of mouse bowel, the small intestine and descending colon. The time-course change in the incidence of apoptosis after each type of radiation could be explained on the basis of the innate circadian rhythm of the cells susceptible to apoptotic death and of the excretion of tritiated water (HTO) from the body. For 6-h continuous gamma irradiation at various dose rates (0.6-480 mGy/h) and for 6 h after injection of HTO of various radioactivities (0.15-150 GBq per kg body wt), the relationships between dose and incidence of apoptosis were obtained. Survival curves were then constructed from the curves for dose vs incidence of ...
New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbeddose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).
New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbeddose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).
It was developed a new formulation of macro aggregates of Samarium 153 ({sup 153} Sm-MH) for the arthropaties treatment. The radio pharmaceutic was prepared by reaction of Samarium 153 chloride (SmCl{sub 3}) in aqueous environment with sodium boron hydride in NaOH 0.5 N. The microscopic analysis shown that the particles have an average size of 4% m (range 1-14 {mu} m). The velocity of sedimentation was 0.008 cm/min with high stability in vitro in human serum. The biological studies in healthy rabbits, shown that the complex is retained inside the articulation still eight days after of the administration of the radiopharmaceutical. Likewise, it is presented the data of absorbeddose in the different target organs, which was determined by thermoluminescent dosimetry (TLD) through the use of a REMCAL phantom (radiation equivalent manikin calibration). (Author)
The radiation induced reactions in LDPE in the presence of phenolic type antioxidants have been studied. It was shown that various antioxidants can influence the polyethylene network formation and the radical yield in different ways. The dependence of network structure on absorbeddoses was determined by gel analysis, hot-set test and extraction of antioxidants for samples irradiated with accelerated electrons. It was found that the antioxidants eluted from polyethylene in higher percentage influence polymer crosslinking to a smaller degree. The ESR studies of #gamma#-irradiated blends of polyethylene with antioxidant indicate the presence of alkyl and phenoxyl radicals. The role of antioxidant molecules on radiation induced reactions in polyethylene-antioxidant systems is considered. The correlation between the network structure and the type of additive in polyethylene is also discussed. (author).
With the exception of the 1945 Hiroshima and Nagasaki nuclear weapon explosions and the 1986 Tchernobyl reactor accident, most of the radiation accidents concerns the medical and the traditional industrial sectors. The seriousness of the accident is directly function of the absorbeddose. The paper, first, gives the definition of a radiologic accident with its specific criteria and pathological manifestations. Then, some famous historical accidents are reviewed from the discovery of X-rays to recent acute irradiations due to the careless manipulation of radiation sources. From this analysis, three main causes are put forward: the dysfunction of nuclear medicine apparatuses, the victims` lack of training and knowledge of the risks, and the non-identification or the loss of radiation sources. (J.S.). 1 photo.
The purpose of this work was to determine the radiolytic hydrogen gas yield of irradiated CSSX solvent at several temperatures. The active ingredient of this solvent is calix[4]arene-bis-(t-octylbenzo) crown-6, a calixarene crown ether used for cesium complexation. The solvent also contains 1-(2,2,3,3-tetrafluoropropoxy)-3-(4-sec-butylphenoxy)-2-propanol, a fluorinated alcoholic solvent modifer used to improve the solubility of the calixarene and its cesium complex in the Isopar L diluent. Isopar L is a branch-chain alkane and comprises most of the mixture. Samples of this solution were irradiated to various absorbed ?-ray doses in gas-tight sample containers, which were then sampled for hydrogen gas content. The methods are described below.
A tissue-equivalent dosimetry system has been developed for use in absorbeddose determinations with physical models of Reference Man. The dosimeter used was a thermo-luminescent dosimeter (TLD) powder which was mixed with a 'tissue-equivalent' material and modeled to closely approximate an organ's geometry and absorption properties. A separation procedure was developed by which the TLD powder was washed and the 'tissue-equivalent' material, a wax, was dissolved and extracted following the irradiation of the model. The procedure was tested to determine losses of powder, homogeneity of the powder's distribution throughout the wax, the effects of the separation procedure upon the powder and the statistical behavior of the procedure. The results of these tests established the feasibility of the procedure. A full-scale model of the pancreas was tested and the results supported the validity of the technique. (author)
Values of the chemical yield, G, and of the molar extinction coefficient, epsilon, for Fricke dosimetry, have been recommended by ICRU. For epsilon, the value in ICRU Reports 17 and 21, 2205 1.mol"-"1.cm"-"1, based on an analysis of 83 reported values. It was suggested that, where neither a careful wavelength calibration nor absorbance linearity checks had been performed, a standard error of 1.5% should be assumed; otherwise 0.15% could be accepted. Alternatively, the accuracy in applying this chemical dose meter was considered improved if there was an independent determination of epsilon with the same spectrophotometer as was used for the determination of the optical density of irradiated Fricke solution. The accuracy claimed for both methods remains questionable, since no complete argumentation could be given for the differences of up to 13% in the published values. Taking into account the discussion of the sources of error by Bryant, ...
The safety of tissue allografts has come under increased scrutiny due to recent reports of allograft-associated bacterial and viral infections in tissue recipients. We report that 50 kGy of gamma irradiation, nearly three times the dose currently used, is an effective pathogen inactivation method when used under optimized conditions that minimize damage to the tissue. Cancellous bone dowels treated with a radioprotectant solution and 50 kGy of optimized irradiation had an ultimate compressive strength and modulus of elasticity equal to conventionally irradiated (18 kGy) and non-irradiated control bone grafts. We subjected bone dowels treated with this pathogen inactivation method to an in vitro cytotoxicity test using three different mammalian cell lines and concluded that the treated grafts were not cytotoxic. The log reduction of nine pathogens spiked into radioprotectant-treated bone irradiated to 50 kGy was also tested. ...
In the case of total skin electron therapy without the beam guide, the electron beam is scattered just outside the gantry exit, dose uniformity in the field is broken, and dose is spread outside the light field. The aims of this study were to measure the mean energy of the off-axis incident electron beam without the beam guide and to establish a reference for the clinical situation. For the measurement, a 4 MeV electron beam was selected among several energies from the linear accelerator. A scintillating fiber beam energy monitor measured the mean energy of the incident electron beam. This energy monitor is a small, light-weight piece of equipment composed of a wedge absorber, scintillation fiber, and photodiode. We found the relationship between electron energy and the indicated value of the energy monitor by means of the estimation of correction factors for five different kinds of electron energy. The preferable linear ...
Processing of food with ionizing radiation is a method suitable to enhance shelf-life and hygienic quality. Up to a dose of 10 kGy the method is considered wholesome. In many countries the practical use of food irradiation is increasing, however, in the Federal Republic of Germany the process is strictly forbidden. Applications and methods for radiation processing of food are compiled, limits and prospects are explained, and advantages and disadvantages are compared with traditional methods. Identification of irradiated foods and dosimetry and process control for radiation processing of food are areas where further research is needed. Continuous processing of particulate foods in bulk is an application where electron accelerators might be profitable. Beam parameters and velocity distribution of food particles in the treatment area can be matched for an effective result. Thus, dose distribution can be adjusted for homogeneous treatment and at ...
The effect of a complexon therapy scheme including early (in 1 h) administration of Na/sub 3/Ca DTPA and subsequent administration of Na/sub 3/Zn DTPA or Na/sub 3/Ca DTPA at a dose of 25 ..mu..Cimol/kg/day by three 2-week courses (5 times a week) with 2-week interruptions was studied in experiments on 541 male rats after intraperitoneal administration of /sup 239/Pu citrate complex (95 kBq/kg). The treatment resulted in a 3-fold lessening of the content of /sup 239/Pu and absorbeddoses in the skeleton, a significant prolongation of the mean survival time (MST) from 452 to 593 days (Na/sub 3/Zn DTPA) and 643 days (Na/sub 3/Ca DTPA), and in a decrease of the osteosarcoma incidence from 76.4 to 32.6-41.2%. The ratio of osteosarcomas per 1 Gy retained in rats (0.076-0.083 %) did not differ from that in untreated animals.
Purpose: calculation of conversion coefficients for the reconstruction of organ doses from entrance doses for abdomen radiographs of 0, 1, 5, 10, 15, and 30-year-old patients in conventional pediatric radiology for the radiographic settings recommended by the German and European guidelines for quality management in diagnostic radiology. Materials und method: using the commercially available personal computer program PCXMC developed by the Finnish Center for Radiation and Nuclear Safety (Saeteilyturvakeskus STUK), conversion coefficients for conventional abdomen radiographs were calculated performing Monte Carlo simulations in mathematical hermaphrodite phantom models describing patients of different ages. The possible clinical variation of beam collimation was taken into consideration by defining optimal and suboptimal radiation fields on the phantoms' surfaces. Results: conversion coefficients for the ...
CT-Expo is a novel MS Excel application for assessing the radiation doses delivered to patients undergoing CT examinations, based on computational methods that were used to analyze the data collected in the German survey on CT practice in 1999. The program enables the calculation of all dose quantities of practical value, such as axial dose free-in-air, weighted CTDI, dose-length product, effective dose and uterine dose. In contrast to existing programs for CT dose assessment, CT-Expo offers a number of unique features, such as gender-specific dose calculation for all age groups (adults, children, newborns), applicability to all existing scanner models including correction of scanner-specific influences, and the possibility of comparison with the results from the German CT survey on CT practice. Three different ...
Non-uniform radionuclide distribution in tumours will lead to a non-uniform absorbeddose. The aim of this study was to investigate how tumour control probability (TCP) depends on the radionuclide distribution in the tumour, both macroscopically and at the subcellular level. The absorbeddose in the cell nuclei of tumours was calculated for {sup 90}Y, {sup 177}Lu, {sup 103m}Rh and {sup 211}At. The radionuclides were uniformly distributed within the subcellular compartment and they were uniformly, normally or log-normally distributed among the cells in the tumour. When all cells contain the same amount of activity, the cumulated activities required for TCP = 0.99 (A-tilde{sub TCP=0.99}) were 1.5-2 and 2-3 times higher when the activity was distributed on the cell membrane compared to in the cell nucleus for {sup 103m}Rh and {sup 211}At, respectively. TCP for {sup 90}Y was not affected by different ...
In order to gain an overall picture of the genetic effects of an increased level of background radiation it is necessary to study the results of protracted exposures to embryonic and immature germ-cell stages as well as to stages found in the mature organism. For this purpose, litters produced by female mice, kept in a 10 or 20 rad/day /sup 60/Co ..gamma..-irradiation field, were kept in the same fields from conception until about 60 days later, having absorbeddoses of 526 and 1078 rad respectively. Tests on exposed female offspring showed them to be sterile. Eight weeks after removal from the gamma field, mean testis masses of males in the 20 rad/day series were only half normal but those receiving 10 rad/day were little affected. Frequencies of translocations in spermatocytes at diakinesis/metaphase I were only slightly increased in the exposed series, differences not being significant. Estimated rates of translocation induction were around ...
In this work, we use lasers to enhance possibilities of laser desorption methods and to optimize coating procedure for capillary electrophoresis (CE). We use several different instrumental arrangements to characterize matrix-assisted laser desorption (MALD) at atmospheric pressure and in vacuum. In imaging mode, 488-nm argon-ion laser beam is deflected by two acousto-optic deflectors to scan plumes desorbed at atmospheric pressure via absorption. All absorbing species, including neutral molecules, are monitored. Interesting features, e.g. differences between the initial plume and subsequent plumes desorbed from the same spot, or the formation of two plumes from one laser shot are observed. Total plume absorbance can be correlated with the acoustic signal generated by the desorption event. A model equation for the plume velocity as a function of time is proposed. Alternatively, the use of a static laser beam for observation ...
Despite high local control rate in Ewing's sarcoma the exact indication of radiation therapy is still controversial as well as the choice of the target volume and the optimaldose of radiation. The importance of the quality of radiotherapy has been stressed in recently published data and has shown a significant impact on long term local control with adequate radiation therapy. The dramatic improvement of precision allowed by the conformal therapy and three dimensional dosimetry allow to expect a decrease of late effects expected for second malignancies. However, late sequelae and radio-induced osteosarcoma still remain the major side effects after radiotherapy. The authors discuss the results of the main trials on Ewing's sarcoma on the choice of dose and target volume. Surgery is still the preferred choice for small tumors if the foreseen outcome is identical. (authors). 28 refs.
In case of a severe nuclear accident at a PWR plant, countermeasures will be initiated in the short term by authorities to reduce the consequences of the atmospheric radioactive releases on the neighbouring population. Various factors influence the level of protection afforded by countermeasures. For instance, a too late intervention would lead to a Jack of efficiency in terms of dose reduction if the actual evolution of the accident is not considered. Thus, implementation of countermeasures should be optimized. In general, the projected doses (those without countermeasure) are compared with those expected when a particular countermeasure or strategy is implemented. In this paper, an in-depth analysis associates the kinetics of the release with the corresponding evolution of the dosimetric efficiency of countermeasures. This is done at different times in the short term of the accident and for various distances from the ...
Background: In an effort to standardise radiological practices in the Republic of Ireland, current legislation states that 'written protocols for every type of standard radiological practice shall be established'. In order to fulfil this requirement the Irish Medical Council recommends the protocols issued by the Commission of European Communitees (CEC) for adoption in the country. Whilst this document does provide good guidance with regard to various radiographic factors, patient shielding instructions are notably ambiguous. The aim of this study was to remove some of this ambiguity by defining the optimal method of positioning patient shielding in antero-posterior (AP) and lateral lumbar spine radiographic examinations. These projections were chosen on the basis of their area of coverage being in close to and in some cases including the reproductive organs. They also represent the highest source of collective population dose ...
Background: In an effort to standardise radiological practices in the Republic of Ireland, current legislation states that 'written protocols for every type of standard radiological practice shall be established'. In order to fulfil this requirement the Irish Medical Council recommends the protocols issued by the Commission of European Communitees (CEC) for adoption in the country. Whilst this document does provide good guidance with regard to various radiographic factors, patient shielding instructions are notably ambiguous. The aim of this study was to remove some of this ambiguity by defining the optimal method of positioning patient shielding in antero-posterior (AP) and lateral lumbar spine radiographic examinations. These projections were chosen on the basis of their area of coverage being in close to and in some cases including the reproductive organs. They also represent the highest source of collective population dose of any ...
The advent of multislice spiral CT (MSCT) technique has led to new aspects of dose reduction, especially for the dedicated use of MSCT in children. Optimizing pediatric MSCT protocols according to the clinical problem allows reduction of radiation exposure to a minimum without loss of diagnostic quality. The different parameters that influence the degree of dose reduction, like tube current-time product (mAs), tube voltage (kV), collimation and pitch, are discussed in context with previously published data and our own experience in nearly 200 pediatric CT examinations. In our department, the effective mAs is calculated for a pediatric chest MSCT by multiplication of the body weight in kilogram with a factor of 1 to 1.5 and for a pediatric abdominal MSCT by multiplication with a factor of 2 to 2.5. To calculate the equivalent effective dose for a contrast media-enhanced 80 kV protocol, the effective mAs ...
Brachytherapy is used for treating certain types of cancer by inserting radioactive sources into tumours. CDTN/CNEN is developing brachytherapy seeds to be used mainly in prostate cancer treatment. Dose calculations play a very significant role in the characterization of the developed seeds. The current state-of-the-art of computation dosimetry relies on Monte Carlo methods using, for instance, MCNP codes. However, deterministic calculations have some advantages, as, for example, short computer time to find solutions. This paper presents a software developed to calculate doses in a two-dimensional space surrounding the seed, using a deterministic algorithm. The analysed seeds consist of capsules similar to IMC6711 (OncoSeed), that are commercially available. The exposure rates and absorbeddoses are computed using the Sievert integral and the Meisberger third order polynomial, respectively. The software ...
In this work dosimetric analysis using thermoluminescence technique to study the beams characteristics of x-rays employed in dental radiology has been carried out. The obtained results with CaSO{sub 4}:Dy thermoluminescent dosimeters (TLD) were compared to the doses obtained with parallel-plates ionization chamber. Dosimetric evaluations were also done using radiographic films of large dimensions. The x-rays equipments analyzed were installed in the radiological services of Odontology Department of Sergipe Federal University (U.F.S.). Depending on the anatomical region to be examined the proper exposure time was select, for a fix voltage of 70 kV. The results with TLD and ionization chamber have been determined to female and male individuals. The intraoral regions analysed were the peri apical of the incisors, molar and pre-molar teeth and the occlusive region. These regions were simulated using acrylic plates absorbers installed on the film ...
Abstracts are presented of 63 papers on the following topics: large-scale optimization, interior-point methods, algorithms for optimization, problems in control, network optimization methods, and parallel algorithms for optimization problems.
Evaluation of the tolerance limits of X-ray image density accepted by the radiologist shows that for different kinds of examinations, deviations of more than 50% from optimal density lead to images which cannot be used diagnostically. Within this range diagnostic accuracy shows a distinct maximum and diminishes to the limits by 20%. These figures are related to differences in the intensifying factor of screens, sensitivity of films, sensitometric parameters of film processing as well as the doses employed with automatic exposure control devices, measured in clinical conditions. Maximum permissible tolerance limits of the whole imaging system and of its constituents are discussed using the Gaussian law of error addition. (author).
Introduction Gastrointestinal bleeding is a common life-threatening problem, causing significant mortality, costs and resource allocation. Its management requires a dynamic multidisciplinary approach that directs diagnostic and therapeutic priorities appropriately. Materials and methods Articles published within the past 15 years, related to gastrointestinal bleeding, were reviewed through MEDLINE search, in addition to current guidelines and standards. Results Decisions of ICU admission and blood transfusion must be individualized based on the extent of bleeding, hemodynamic profile and comorbidities of the patient and the risk of rebleeding. A secure airway may be required to optimize oxygenation and to prevent aspiration. Doses of induction agents must be reduced due to the changes in v...
This paper describes research and development activities at the University of Regina, Saskatchewan, Canada on Optimization of CO{sub 2} Extraction Process Technologies. The ultimate goal of this research is to develop better and more effective CO{sub 2} separation processes which can be used to recover CO{sub 2} from industrial sources such as coal-fired power plants and coal gasification complexes at the lowest possible capital and operating costs. The research program has been supported by Saskatchewan Power Corporation, Saskatchewan Energy and Mines, Prairie Coal Ltd., the Canada Centre for Mineral and Energy Technology (CANMET), Fluor Daniel Inc. (USA), Sulzer Chemtech (Switzerland), Wascana Energy Inc., and Natural Sciences and Engineering Research Council of Canada (NSERC). Currently, six parallel and complementary projects have been carried out at the Process Systems Laboratory. These projects are: (1) Searching for new sterically hindered amines for high ...
Purpose: Photodynamic therapy (PDT) is based on the interaction of a photosensitizing (PS) agent, light, and oxygen. Few new PS agents are being developed to the in vivo stage, partly because of the difficulty in finding the right treatment conditions. Response surface methodology, an empirical modeling approach based on data resulting from a set of designed experiments, was suggested as a rational solution with which to select in vivo PDT conditions by using a new peptide-conjugated PS targeting agent, neuropilin-1. Methods and Materials: A Doehlert experimental design was selected to model effects and interactions of the PS dose, fluence, and fluence rate on the growth of U87 human malignant glioma cell xenografts in nude mice, using a fixed drug-light interval. All experimental results were computed by Nemrod-W software and Matlab. Results: Intrinsic diameter growth rate, a tumor growth parameter independent of the initial volume of the tumor, was selected as ...
Optimal design of the hyperfractionated radiotherapy requires basic radiobiological data such as the critical dose per fraction, number of fractions per day and total equivalent dose, to name a few. As a prelude to in vivo hyperfractionated irradiation, the authors carried out experiments to determine quantitative changes in the proliferation and cell kinetic parameters of multicellular spheroids after hyperfractionated irradiation. Experiments were carried out with HeLa S-3 spheroid growing in MEM culture media. Hyperfractionated irradiation schedules were 1.5 Gy/f, 2f/day and 1.0 Gy/f, 3 f/day. At intervals after irradiation, cell numbers, growth delays and cell cycle distribution of spheroids were determined. The kinetic data were obtained by the use of flow cytometry. The most pronounced changes in cell kinetic parameters were early G/sub 2/M block, proportional to single radiation dose up to 4.0 ...
Purpose: An inverse treatment planning algorithm for tomotherapy is described. Methods and Materials: The algorithm iteratively computes a set of nonnegative beam intensity profiles that minimizes the least-squares residual dose defined in the target and selected normal tissue regions of interest. At each iteration the residual dose distribution is transformed into a set of residual beam profiles using an inversion method derived from filtered backprojection image reconstruction theory. These 'residual' profiles are used to correct the current beam profile estimates resulting in new profile estimates. Adaptive filtering is incorporated into the inversion model so that the gross structure of the dose distribution is optimized during initial iterations of the algorithm, and the fine structure corresponding to edges is obtained at later iterations. A three dimensional, kernel based, ...
Background: The effective-dose method which was proposed by the ICRP (International Commission of Radiation Protection) for the estimation of risk to the general population from occupational or environmental, low-dose radiation exposure is not adequate for estimating the risk of cancer induction by radiotherapy of malignant or nonmalignant diseases. Methods:The risk of cancer induction by radiotherapy of benign diseases should be based on epidemiologic data directly derived from follow-up studies of patients who had been given radiotherapy for nonmalignant diseases in the past. Results: Risk factors were derived from epidemiologic studies of patients treated with irradiation for nonmalignant diseases to be used for selecting treatment options and optimizing treatment procedures. Conclusion: In most cases, cancer risks estimated by the effective-dose method may overestimate the true risks by one order of ...
Background: The effective-dose method which was proposed by the ICRP (International Commission of Radiation Protection) for the estimation of risk to the general population from occupational or environmental, low-dose radiation exposure is not adequate for estimating the risk of cancer induction by radiotherapy of malignant or nonmalignant diseases. Methods:The risk of cancer induction by radiotherapy of benign diseases should be based on epidemiologic data directly derived from follow-up studies of patients who had been given radiotherapy for nonmalignant diseases in the past. Results: Risk factors were derived from epidemiologic studies of patients treated with irradiation for nonmalignant diseases to be used for selecting treatment options and optimizing treatment procedures. Conclusion: In most cases, cancer risks estimated by the effective-dose method may overestimate the true risks by one order of ...
The pentenary compound semiconductor Cu(In,Ga)(Se,S)2 is one of the most attractive materials for high-efficiency solar cells due to its tunable band gap to match well the solar spectrum. In this study, semiconducting Cu(In,Ga)(Se,S)2 thin films were prepared by a classical two-step growth process, which involves the selenization and/or sulfurization of In/Cu?Ga precursor. During the precursor formation step metallic In/Cu?Ga alloys were deposited onto the Mo-coated soda-lime glass substrates by DC magnetron sputter process. The respective precursors were subsequently reacted with H2Se and/or H2S gasses, at elevated temperatures. By optimizing the selenization parameters, such as the gas concentrations, reaction time, reaction temperature, and the flow of H2Se and H2S, high quality, single...
A helical cooling channel (HCC) has been proposed to quickly reduce the six-dimensional phase space of muon beams for muon colliders, neutrino factories, and intense muon sources. The HCC is composed of a series of RF cavities filled with dense hydrogen gas that acts as the energy absorber for ionization cooling and suppresses RF breakdown in the cavities. Magnetic solenoidal, helical dipole, and helical quadrupole coils outside of the RF cavities provide the focusing and dispersion needed for the emittance exchange for the beam as it follows a helical equilibrium orbit down the HCC. In the work presented here, two Monte Carlo programs have been developed to simulate a HCC to compare with the analytic predictions and to begin the process of optimizing practical designs that could be built in the near future. We discuss the programs, the comparisons with the analytical theory, and the prospects for a HCC design with the capability to reduce the ...
Iron oxide thin films have been obtained by spray pyrolysis using 100% methanolic and ethanolic solutions of iron tri-chloride. The films were deposited onto ITO-coated glass substrates. The preparative conditions have been optimized to obtain compact, pin-hole-free and smooth thin films which are adherent to the substrate. The structural, morphological and compositional characterizations have been carried out by X-ray diffraction, scanning electron microscopy and energy dispersive X-ray analysis. The films deposited using ethanolic solution results into pure hematite; #alpha#-Fe_2O_3 thin films, however, films deposited using methanolic solution consists of hematite and maghemite-c phases of iron oxide. The films are nanocrystalline with particle size of 30-40 nm. The optical absorbance of the film was of the order of 10"5 cm"-"1. The optical band gap of films was found to be 2.26 and 2.20 eV for the films deposited using methanolic and ...
A combined PVD/PECVD process for the vacuum deposition of titanium containing amorphous hydrogenated carbon films is described. Elemental compositions of the deposited films have been determined by in situ core level photoelectron spectroscopy (XPS). The long-term stability of the plasma process has been demonstrated. Target poisoning has not been observed. We have fabricated optical selective surfaces by the deposition of a-C:H/Ti multilayers onto aluminum substrates. Even though we have not optimized layer thicknesses and stoichiometries so far, the experimental results are promising: solar absorptance {alpha}{sub S} of 0.876 and thermal emittance {epsilon}{sub 100C} of 0.061 have been achieved yielding an optical selectivity sis defined as{alpha}{sub S}/{epsilon}{sub 100C} of 14.4. Accelerated aging tests of these coatings have demonstrated their aging stability: the service lifetime is predicted to amount to more than 25 years. Raman spectroscopy has been used ...
Full text: A semiempirical algorithm for absorbeddose calculation at off-axis points in irregular beams was implemented. It is well known that semiempirical methods are very useful because of their easy implementation and its helpfulness in dose calculation in the clinic. These methods can be used as independent tools for dosimetric calculation in many applications of quality assurance. However, the applicability of such methods has some limitations, even in homogeneous media, specially at off axis points, near beam fringes or outside the beam. Only methods derived from tissue-air-ratio (TAR) or scatter-maximum-ratio (SMR) have been devised for those situations, many years ago. Despite there have been improvements for these manual methods, like the Sc-Sp ones, no attempt has been made to extend their usage at off axis points. In this work, a semiempirical formalism was introduced, based on the works of Venselaar et al. ...
The central benzodiazepine receptor tracer [N-methyl-"1"1C]iomazenil (Ro 16-0154) was synthesized by alkylation of the desmethyl precursor noriomazenil with ["1"1C]methyl iodide. The ["1"1C]CH_3I (prepared by reduction of ["1"1C]CO_2 with LiAlH_4 followed by reaction with HI) was reacted with noriomazenil inN,N -dimethylformamide and Bu_4N"+OH"- for 1 min at 80 deg. C and purified by HPLC (C_1_8, 34% CH_3CN/H_2O, 7 mL/min). The product was obtained with synthesis time 35 #+-# 5 min (mean #+-# SD, n = 7), radiochemical yield (EOB) 36 #+-# 16%, radiochemical purity 99 #+-# 1%, and specific activity 5100 #+-# 2800 mCi/#mu#mol. Absorbed radiation doses were calculated from previously acquired human biodistribution data. The urinary bladder wall received the highest dose (0.099 mGy/MBq) for 4.8 h voiding interval and the effective dose equivalent was 0.015 mSv/MBq. After i.v. injection of ["1"1C]iomazenil in ...
Molybdenum is an essential element for living organisms. Moreover its radionuclides may represent an incorporation risk for members of the public and/or radiation workers after a nuclear accident or a release of radioactive materials. However, only few reliable data on Mo biokinetics in humans were available. The results of recent tracer kinetic investigations with stable isotopes have shown several differences from the ICRP data with regard to the processes of intestinal absorption and of excretion. As a consequence, the dose coefficients calculated with a revised biokinetic model deviate from the ICRP estimates. By ingestion of {sup 99}Mo radionuclides with solid food, for example, the dose to the colon may be higher of a factor up to 1 order of magnitude, due to the fraction of non-absorbed material which traverses the gastro-intestinal tract. (orig.) [Deutsch] Molybdaen ist einerseits ein fuer Lebewesen essentielles ...
The distribution of carrier free lead-203 between plasma and cells of canine blood in vitro was measured. Activity in the plasma decreased to less than 5% of the initial blood activity during the first 15 min and then exponentially with a half time of 160 min. Incubation in cell free plasma before addition to whole blood transformed the isotope, decreasing the amount subsequently associated with cells. In animal studies, activity was measured in plasma, blood cells, urine, and feces after exposure to lead-203. In one group, the animals were exposed by intravenous injection of dilute citric acid solutions of isotope. In a second group, carrier free isotope which had been transformed by incubation in plasma was injected intravenously. The kinetics of the distribution of the isotope differed between the two experimental groups. After injection of the transformed lead, the lead-203 content of the blood cell fraction rose from 10% of the dose at 5 min to 21% to 43% at ...
Hepatocellular carcinoma (HCC) is the most common primary liver cancer and has very limited therapeutic options. Recently, it has been found that hyaluronic acid (HA) shows selective binding to CD44 receptors expressed in most cancer histotypes. Since the trend in cancer treatment is the use of targeted radionuclide therapy, the aim of this research was to label HA with rhenium-188 and to evaluate its potential use as a hepatocarcinoma therapeutic radiopharmaceutical. Methods: {sup 188}Re-HA was prepared by a direct labelling method to produce a ReO(O-COO){sub 2}-type coordination complex. {sup 188}Re-HA protein binding and its stability in saline, phosphate buffer, human serum and cysteine solutions were determined. Biokinetic and dosimetric data were estimated in healthy mice (n=60) using the Medical Internal Radiation Dose methodology and mouse model beta-absorbed fractions. To evaluate liver toxicity, alanine aminotranferase (AST) and ...
The Seismic Proving Test of Heavy Component with Energy Absorbing Supports has been conducted to prove the reliability of advanced seismic technology, supporting heavy component such as PWR steam generator with large capacity energy absorbing supports under the sponsorship of Ministry of Economical Trade and Industry. If energy absorbing supports are adopted for NPP heavy components, support structure of facility will be much simplified due to their seismic energy absorbing effect. The paper describes the results of lead damper element test and seismic test at Tadotsu Laboratory, using 1/2.5 scale PWR Steam Generator model supported by Lead Extraction Damper (LED) and development of characteristics evaluation formula of energy absorbing support. (author)
Color formation in aqueous solutions of the ditetrazolium salt blue tetrazolium (BT{sup 2+}) in the absence or presence of oxygen is a complex radiation chemical reaction. The final stable product is the poorly soluble diformazan violet to blue pigment having a broad spectral absorption band ({lambda}{sub max}=552 nm). The reaction of BT{sup 2+} with the hydrated electron proceeds by rapid reduction of BT{sup 2+} followed by protonation at the nitrogen closest to the unsubstituted phenyl group, via the two intermediate tetrazolinyl radicals shared by the ditetrazole ring nitrogens. The effect of solution pH, N{sub 2}O saturation, and the presence of the reducing agent dextrose are examined. The system serves as a radiochromic sensor and a dosimeter of ionizing radiations. Solutions of 5 mmol l{sup -1} BT{sup 2+} at pH 7.3 serve as dosimeters over an absorbed-dose range of approximately 0.2-6 kGy (dearated, with a range of 1-8 mmol l{sup -1} dextrose) and of about ...
Natural radioactive materials under certain conditions can reach hazardous radiological levels. The natural radionuclide ({sup 238}U, {sup 232}Th, {sup 40}K) contents of rock samples at various locations in the North Tushki area were investigated using gamma-spectrometric analysis. Estimates of the measured radionuclide content have been made for the absorbeddose rate of gamma radiation. The equivalent radium (R{sub eq}) and the external hazard index (H{sub ex}) which resulted from the natural radionuclides in soil are also calculated and tabulated. The studied samples have been collected from various rock exposures in the North Tushki area. The distribution of major oxides, U and Th were studied. It is found that the enrichment and depletion of the major oxides are mainly due to the effect of hydrothermal alteration, which caused mobility of some major oxides, which increases some elements and decreases others. It is important to mention that ...
Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbeddose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement result shows extremely high radiation level ...
Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbeddose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement result shows extremely high radiation level ...
The bioavailability of lead was studied in rats fed various baby foods (Babymix-turkey, Babymix-vegetables, Frutolino-fruit, Frutamix-bananas, Babyron-S-26, Truefood), cow's milk, bread, liver and standard rat diet. Lead absorption was determined by measuring the whole body retention of "2"0"3Pb 6 days after a single oral application. Highest absorption values ranging from 17 to 20% were obtained in animals fed cow's milk and fruit foods. Rats on other human diets absorbed between 3 and 8% of the radioactive lead dose. Only in animals on rat diet lead absorption was below 1%. It is concluded that rats fed human diets show absorption values similar to those in humans. This might indicate that the bioavailability of lead is primarily dependent on dietary habits. This experimental model, if confirmed by further work, might be useful for obtaining preliminary data on the bioavailability of metals from various foods.
In the convolution/superposition algorithm, the energy spectrum should be modified to make the reconstructed dose distribution consistent with the measured dose distribution. The energy spectrum, which gives the best agreement, is not determined uniquely depending on the reconstruction procedure. In this report, the effects of the characteristics of the energy spectrum on the calculation accuracy are evaluated by comparing the percentage depth dose (PDD) and beam profiles for the reference energy spectrum with those calculated for the modified spectrum in order to optimize the energy spectrum modification procedure when 4 and 10 MV X-ray beams are used. Decreasing the number of energy bins brought a larger decrease rate in the computation accuracy than a decrease rate in computation time. Further, the decrease of the number of energy bins led to a change of the energy spectrum. The balance of the ...
Purpose: The purpose of this course is to review the physical principles underlying design, clinical application and execution of interstitial and intracavitary implants in the classical low dose-rate (LDR) range. This year, the course will focus on quality assurance of sources, applicators and treatment planning software. In addition, development of procedures and QA checks designed optimize treatment delivery accuracy and patient safety during each individual procedure will be reviewed. The level of presentation will be designed to accommodate both physicists and physicians. Implementation of recently published AAPM Task Group reports (no. 40, 'Comprehensive Quality Assurance' and No. 43, 'Dosimetry of Interstitial Brachytherapy Sources') will be reviewed. Outline: (A) General Principles (1) QA endpoints: temporal accuracy, positional accuracy, dose delivery accuracy, and safety of the patient, personnel, and the ...
The role of radiation therapy in local tumor control and decreased incidence of pulmonary metastasis is reported in 271 patients who were entered into the Intergroup Ewing's Sarcoma Study with more than one year follow-up and on whom all radiotherapy records were reviewed. The majority of the patients were irradiated to the primary tumor with doses of 4500 to 6500 rad in five to six weeks in combination with systemic administration of three drugs (vincristine, actinomycin-D and cyclophosphamide) or four drugs (vincristine, actinomycin-D, cyclophosphamide and adriamycin). One of the groups of patients was treated with three drugs and bilateral pulmonary irradiation (1500 rad, uncorrected dose, in two weeks). Preliminary analysis shows an overall local primary tumor control of 89%. Patients with lesions in the pelvis had a local failure rate of 17% (9 of 52) and in the humerus 23% (7 of 31). Factors affecting local recurrences are analyzed in ...
The theoretical analysis of a partially-ionized hydrogen gas flow (gas temperatures of approximately 10,000 to 20,000 K) through a particular class of magnetohydrodynamic (MHD) generators and the preliminary design of these MHD generators as open cycle, electric power supplies are performed. Analysis of the gas flow through these ultra-high temperature MHD generators requires a coupled gas dynamics/radiative heat transfer solution. Gas dynamics are modeled by a set of quasi-one-dimensional, nonlinear differential equations which account for friction, convective and radiative heat transfer and the interaction between the ionized gas and applied magnetic field. Radiative heat transfer is modeled using non-gray, absorbing-emitting two- and three-dimensional P-1 approximations which permit an arbitrary variation of the spectral absorption coefficient with frequency. Gas dynamics and radiative heat transfer are coupled through the energy equation, and through the ...
Digital control technology using micro-processor is widely used in Factory Automation area since 1980`s. However, the D{sub 2}O Vapour Recovery System in Wolsung 1 N.P.P is controlled by mechanical timer without considering the moisture condition in the Reactor Building and bed temperature, because it was designed using analog technology of 1960`s. This leads to the inefficient system operation and low D{sub 2}O recovery rate in addition to the high internal dose rate of operator. The goal of this phase II study is to develope a optimal automatic controller of D{sub 2}O vapour recovery system using PLC. We developed a control algorithm for Dual Tower Drier, a PLC control program, a operation change program and the monitoring system with a real-time simulator for system verification. (author). 15 refs., 11 figs., 2 tabs.
The thin windows for the Muon Ionization Cooling Experiment (MICE) liquid Absorber will be fabricated from 6061-T6-aluminum. The absorber and vacuum vessel thin windows are 300-mm in diameter and are 180 mm thick at the center. The windows are designed for an internal burst pressure of 0.68 MPa (100 psig) when warm. The MICE experiment design calls for changeable windows on the absorber, so a bolted window design was adopted. Welded windows offer some potential advantages over bolted windows when they are on the absorber itself. This report describes the bolted window and its seal. This report also describes an alternate window that is welded directly to the absorber body. The welded window design presented permits the weld to be ground off and re-welded. This report presents a thermal FEA analysis of the window seal-weld, while the window is being welded. Finally, the results of a ...
Ten children receiving maintenance dialysis were immunized with the standard dose of measles-mumps-rubella vaccine between 15 and 33 months of age. Immune responses to vaccination were determined using commercially available enzyme-linked immunosorbent assays for measles, mumps, and rubella viruses. Eight children responded to measles vaccine, 5 to mumps vaccine, 8 to rubella vaccine, and only 3 children to all three vaccines, compared with a seroconversion rate of over 90% to all three vaccines in healthy children (P less than 0.0001). We contend that the relatively poor immunocompetence of our dialysis patients explains their less than optimal vaccine response and suggest that children vaccinated while undergoing dialysis be tested to confirm serological evidence of immunity. PMID:1571219
BackgroundOptimal treatment of primary negative symptoms is important because their presence is associated with poor outcome.AimsTo systematically review all studies dealing with the efficacy of pharmacological agents on primary negative symptoms.MethodA comprehensive search of the relevant literature was undertaken using electronic database, reference lists and personal contact.ResultsThere is a lack of standardized research designs. Amisulpride is the most extensively studied drug with respect to efficacy against primary negative symptoms. At low doses it demonstrates a consistent, modest effect compared to placebo, though not to conventional antipsychotics and has yet to be tested against other atypicals. Evidence from multiple studies that used simple statistical analyses and inclusion...
The site-selective growth of InAs quantum dots (QDs) by a combined focused ion beam (FIB) and molecular beam epitaxy (MBE) process has been demonstrated. An array of FIB modified spots on MBE grown GaAs was fabricated. Thereafter, an in situ annealing step followed by InAs deposition was performed. The InAs QDs were preferentially formed in the holes generated by the FIB. The influences of ion dose, annealing parameters, and InAs amount were investigated. With optimized parameters, the authors observe more than 50% single dot occupancy per holes. Photoluminescence spectra confirm the good optical quality of the QDs.
Abstract Micronutrient deficiencies are a public health concern among young children in low-income countries, and novel strategies are needed to improve the nutritional status of children at risk. One promising approach is the use of lipid-based nutrient supplements (LNS), which can be added to complementary food at the time of consumption. The optimal amount of zinc to include in LNS is uncertain, and concerns have been expressed about possible adverse effects of zinc on sensory characteristics of LNS. We conducted a series of acceptability studies of LNS containing either 0 or 10-mg of zinc per daily 20-g LNS dose among Burkinabe children 9-15 months old and their mothers. These acceptability studies included observations of children's consumption, maternal and child sensory reaction to ...
Irradiation of live bivalve molluscs is a promising new technique to reduce the public health threats of viral and bacterial pathogens in the consumption of raw shellfish. In studies conducted within the past year, live hardshelled clams and oysters were innoculated with Simian Rotavirus SA-11, Poliovirus I, and Hepatitis-A virus and treated with gamma ray ionizing radiation from University of Lowell/DOE 800,000 Curie "6"0Co source over a dose range of 0.5--10 kiloGray (50--1000 kilorad) to determine the effectiveness of the process in eliminating viral activity and thus easing the potential viral health threats associated with uncooked bivalves. Two viral strains, SA-11 and Poliovirus I, were employed as models to perfect laboratory technique and to estimate the most appropriate range of dose exposures necessary for optimal inactivation of the infectious pathogen, Hepatitis A. Post-irradiation survivorship of the oysters ...
The purpose of this study was to determine the optimal technique for delivering postoperative radiotherapy for vulvar cancer and other tumors requiring treatment of the inguinal nodes. This project compared tumor coverage and normal tissue sparing for the 5 main radiotherapy techniques that are used to treat vulvar cancer. The intensity-modulated radiation therapy (IMRT) plan was undesirable because it resulted in an excessive dose to portions of the central pelvic structures. The photon thunderbird with skin match was unacceptable because it underdosed a portion of the groin region. The electron thunderbird was ideal for thin patients but was not applicable for most patients because of excessive dose to the skin and subcutaneous tissues. The photon through-and-through and the photon thunderbird with deep match were acceptable in most situations. In thin patients, where the depth of the inguinal vessels is less than 3 cm, ...
Full text: Production: This radio iodine produced by three methods: 1) Wet method: The irradiated tellurium is dissolved in an oxidizing mixture which also converts iodine in to iodide. This is a chemical method and iodine that it produced with this method has low purity and efficiency. 2). Dry Method: The irradiated tellurium is dissolved in furnace (750 deg. C) with sublimation method and iodine absorbed in sodium solution . In this case we have more than 99.5 % purity and 80 % efficiency. We are using this type in Iran. 3) Fission fragment method: In this case the iodine separated from fission fragment directly and we have high purity (career free) and specific activity of iodine. Application: Iodine is a versatile tracer element. It is used to determine thyroid cancer metastases, and size, shape and activity of the thyroid gland. Critical organ of iodine is thyroid gland. One of the common diagnostic procedures for determining thyroid function therefore, is to ...
A number of ion exchange materials are being evaluated as part of the Tank Waste Remediation System (TWRS) Pacific Northwest Laboratory (PNL) Pretreatment Project for the removal of "1"3"7Cs from aqueous tank wastes. Two of these materials are organic resins; a phenol-formaldehyde resin (Duolite CS-100) produced by Rohm and Haas Co. (Philadelphia, Pennsylvania) and a resorcinol-formaldehyde (RF) resin produced by Boulder Scientific Co. (Mead, Colorado). One of the key parameters in the assessment of the organic based ion exchange materials is its useful lifetime in the radioactive and chemical environment that will be encountered during waste processing. The focus of the work presented in this report is the radiation stability of the CS-100 and the RF resins. The scope of the testing included one test with a sample of the CS-100 resin and testing of two batches of the RF resin (BSC-187 and BSC-210). Samples of the exchangers were irradiated with a "6"0Co source to a total ...
A number of ion exchange materials are being evaluated as part of the Tank Waste Remediation System (TWRS) Pacific Northwest Laboratory (PNL) Pretreatment Project for the removal of {sup 137}Cs from aqueous tank wastes. Two of these materials are organic resins; a phenol-formaldehyde resin (Duolite CS-100) produced by Rohm and Haas Co. (Philadelphia, Pennsylvania) and a resorcinol-formaldehyde (RF) resin produced by Boulder Scientific Co. (Mead, Colorado). One of the key parameters in the assessment of the organic based ion exchange materials is its useful lifetime in the radioactive and chemical environment that will be encountered during waste processing. The focus of the work presented in this report is the radiation stability of the CS-100 and the RF resins. The scope of the testing included one test with a sample of the CS-100 resin and testing of two batches of the RF resin (BSC-187 and BSC-210). Samples of the exchangers were irradiated with a {sup 60}Co source to a total ...
The patients studied were referred for routine abscess localization with indium-111 labelled autologous leukocytes. One series (n=15) was studied at 1 day after reinjection of labelled cells and a second series (n=9) was studied between 4 hours and 4 days after reinjection of labelled cells. The leukocytes were isolated by a gravity sedimentation method and labelled with In-111 oxinate according to Roevekamp and co-workers. The labelled cell suspension administered to the patient contained between 11 and 15 MegaBq (300-400 microCi). The indium-111 concentration in the liver and spleen was quantitated using a scintillation camera and an on-line computer system. Phantom studies were carried out to obtain conversion factors from geometric mean counts to MegaBq of activity for both liver and spleen. Once determined, the amount of activity in liver and spleen was corrected for physical decay of In-111 and expressed as a percentage of the administered activity. Additionally in the 2nd series ...
To evaluate a dose conversion factor from the `Working Level of Month` (WLM) of radon to the absorbeddose (mGy), the quality of radon and its progeny was assessed, and exposures controlled for each deposition region were planed as follows: 1) exposure of radon gas to the entire respiratory tract, 2) exposure of `unattached` fractions to the upper respiratory tract, 3) exposure of `attached` fractions onto ultrafine particles to the deep lung, 4) exposure of `attached` fractions onto fine particles to the lower respiratory tract, 5) exposure of `attached` fractions onto coarse particles to the upper respiratory tract. In this preliminary study, a prototype exposure system of radon and its progeny for small rodents was designed. A whole body exposure chamber with a volume of about 0.5 m{sup 3} was used, which it held 20 rats. The aging and mixing chamber separated by the exposure chamber had a volume of about 1 m{sup 3}. As ...
The optically stimulated luminescence (OSL) results a highly appropriate dosimetric technique for readings of absorbed radiation 'in alive' and 'in situ', as well as in real time. The CVD diamond on the other hand presents excellent qualities like radiation reader thanks to its reproducibility, radiation resistance, biocompatibility and non toxicity. The present work studies the answer of two diamond films pure and polluted with nitrogen (750 ppm) grown by the Chemical Vapor Deposition method (CVD) on silicon substrate (001) irradiated with beta (Sr-90) in the 0.833-100 Gy interval. The optical stimulation was carried out by 40 seconds with infrared laser (830 nm, 0.36 W/cm{sup 2}) and the filter BG-39 (300-600 nm) coupled the PM. The intensity and the decay of the hyperbolic type of the LOE curves were similar in both samples, for the non doped diamond were observed trapping states in 200-380 C being compared with those that it ...
Cinnabar, a naturally occurring mercuric sulfide (HgS), has long been used in combination with traditional Chinese medicine as a sedative for more than 2000 years. Up to date, its pharmacological and toxicological effects are still unclear, especially in clinical low-dose and long-term use. In this study, we attempted to elucidate the effects of cinnabar on the time course of changes in locomotor activities, pentobarbital-induced sleeping time, motor equilibrium performance and neurobiochemical activities in mice during 3- to 11-week administration at a clinical dose of 10 mg/kg/day. The results showed that cinnabar was significantly absorbed by gastrointestinal (G-I) tract and transported to brain tissues. The spontaneous locomotor activities of male mice but not female mice were preferentially suppressed. Moreover, frequencies of jump and stereotype-1 episodes were progressively decreased after 3-week oral administration ...
The present study was designed to investigate, in more detail, the mechanism of lead transport by the gastrointestinal tract and particularly the similarities or dissimilarities between lead and calcium in this process. The absorption of these metals was determined in 3-week-old white Leghorn cockerels, raised on a commercial diet or special diets, using an in vivo ligated loop procedure. The dose administered into the loop usually contained 0.5 ..mu..Ci /sup 203/Pb (and/or 0.1 ..mu..Ci /sup 47/Ca), 0.01 mM lead acetate (and/or 1 mM CaCl/sub 2/) in 0.5 ml of 0.15 M NaCl, pH 6.5. It was shown that lead is rapidly taken up by the intestinal tissue, and only slowly transferred into the circulation whereas calcium, also accumulated rapidly by the tissue, is rapidly released from the tissue in the serosal direction. The absorption processes of these cations show similar responses to various experimental conditions (low calcium intake, age of the animal, pH of the ...
Electron beams as a source of directed energy are under study at the Lawrence Livermore National Laboratory (LLNL). An intense 10-kA, 50-MeV, 50-ns full-width half-maximum, pulsed electron beam is generated by the prototype Advanced Test Accelerator (ATA) at the Laboratory's Site 300. Whenever the electron beam is stopped in materials, intense radiation is generated. Estimates based on available data in the literature show that for materials such as lead, photon radiation (x ray, gamma, bremsstrahlung) levels can be as large as 10"4 roentgens per pulse at 1 m in the zero-degree direction (i.e., the electron-beam direction). Neutrons, which are emitted isotropically, are produced at a level of 10"1"3 n/m"2 per pulse. Depending upon the number of pulses and the shielding geometry, the accumulated dose is potentially lethal to personnel and potentially damaging to instrumentation that may be used for diagnostics. To provide shielding for minimizing the risk of ...
Full text: Introduction. Children, especially premature infants and neonates, are at a much higher risk to obtain an X ray induced disturbance of life - particularly cancer. On the one hand this is due to their longer life expectancy and on the other hand it is due to their higher cell proliferation rate. The paediatric radiology unit of the Inselspital Bern recently installed some of the most advanced X ray equipment nowadays available. It is based on the two latest digital technologies: double read computed radiography (CR) and direct digital radiography (DR). Only the implementation of these digital radiography systems permits the digital acquisition and additionally the analysis of acquired data. The systematic analysis of large amounts of biometric data and exposition data is the basis for further dose reduction and a systematic quality control (QC). Patients are increasingly critical concerning radiation exposure - especially parents regarding their children. ...
The radiation decimal reduction dose (D_1_0) of toxigenic Vibrio cholerae O1 El Tor, Inaba was determined in vitro (0.13 kGy) and in inoculated fresh fillets of saurel (Trachurus picturatus murphyi) (0.12 kGy) and another Pacific fish species known in Peru as ''lisa'', Mugil cephalus (0.13 kGy), both of which are frequently consumed raw in ''ceviche''. The D_1_0 value was similarly determined in tails of the shrimp species Penaeus vannamei (0.13 kGy). In a second phase of the study, radiation doses in the range 1.0-4.0 kGy were evaluated for use in microbiological shelf-life extension of the selected seafood, and for adverse effects on various sensory attributes (appearance, odor, flavor, and texture). A dose of 1.0 kGy doubled the microbiological shelf-life of fish fillets during post-irradiation storage at 0-1 deg. C to approximately 30 days. This dose was deemed optimal also for ...
The Radiation Technology Center from IPEN-CNEN/SP, Brazil, developed a revolutionary design and national technology, a small-sized continuous run and multipurpose industrial gamma irradiator, to be used as a demonstration facility for manufacturers and contract service companies, which need economical and logistical in-house irradiation system alternatives. Also, to be useful for supporting the local scientific community on development of products and process using gamma radiation, assisting the traditional and potential users on process validation, training and qualification of operators and radioprotection officers. The developed technology for this facility consists of a continuous tote box transport system, comprising a single concrete vault, where the automated transport system of products inside and outside of the irradiator utilizes a rotating door, integrated with the shielding, avoiding the traditional maze configuration. Covering 76 m"2 of floor area, the irradiator design is ...
Background and Purpose: Total-body irradiation (TBI) is an important part of the conditioning regimen for hematopoietic stem cell transplantation (HSCT) in patients with hematologic malignancies. The results after treatment with various TBI regimes were compared, and dose-effect relationships for the endpoints relapse incidence, disease-free survival, treatment-related mortality, and overall survival were derived. The aim was to define requirements for an optimal treatment schedule with respect to leukemic cell kill and late normal-tissue morbidity. Material and Methods: A literature search was performed. Three randomized studies, four studies comparing results of two or three TBI regimens, and nine reports with results of one specific TBI regimen were identified. Biologically effective doses (BEDs) were calculated. The results of the randomized studies and the studies comparing results of two or three TBI regimens were ...
Background and Purpose: Total-body irradiation (TBI) is an important part of the conditioning regimen for hematopoietic stem cell transplantation (HSCT) in patients with hematologic malignancies. The results after treatment with various TBI regimes were compared, and dose-effect relationships for the endpoints relapse incidence, disease-free survival, treatment-related mortality, and overall survival were derived. The aim was to define requirements for an optimal treatment schedule with respect to leukemic cell kill and late normal-tissue morbidity. Material and Methods: A literature search was performed. Three randomized studies, four studies comparing results of two or three TBI regimens, and nine reports with results of one specific TBI regimen were identified. Biologically effective doses (BEDs) were calculated. The results of the randomized studies and the studies comparing results of two or three TBI regimens were ...
The radionuclide characteristics of light-water-reactor (LWR) spent fuel play key roles in the design and licensing activities for radioactive waste transportation systems, interim storage facilities, and the final repository site. Several areas of analysis require detailed information concerning the time-dependent behavior of radioactive nuclides including (1) neutron/gamma-ray sources for shielding studies, (2) fissile/absorber concentrations for criticality safety determinations, (3) residual decay heat predictions for thermal considerations, and (4) curie and/or radiological toxicity levels for materials assumed to be released into the ground/environment after long periods of time. The crucial nature of the radionuclide predictions over both short and long periods of time has resulted in an increased emphasis on thorough validation for radionuclide generation/depletion codes. Current radionuclide generation/depletion codes have the capability to follow the ...
... energy absorption characteristics of composite sandwich panels, thermoplastic energy-absorbing subfloor structures, and shoulder belt pre- tensioners. ...
Random motion of a particle, emitting and absorbing tachyons, is investigated. It is shown that if bradyon is in equilibrium with neutral gas, i.e. it absorbs and emits tachyons, which do not have any charges, tha particle with each absorption-emittance of a tachyon changes its energy and momentum, never varying its own mass, and as a result it moves like a brownian particle. Thus, bradyon, interacting with tachyon gas, increases its momentum continuously in agreement with the Einstein-Fokker-Planck type equation.
This paper is a progress report on the role of radiation therapy (RT) in local tumor control and the decreased incidence of pulmonary metastasis in 251 patients entered in the Intergroup Ewing's Sarcoma Study. All were followed for more that 1 year, and their RT records were reviewed. Doses to the primary tumor in the range of 4,500--6,500 rad were administered over approximately 5 to 6 weeks in combination with 4 drugs, i.e., vincristine (VCR), dactinomycin (DAC), cyclophosphamide (CY), and adriamycin, or only the first 3. One group of patients received the 3 drugs and bilateral pulmonary irradiation (approximately 1,500 rad in 2 wk). Preliminary analysis showed a local primary tumor control of approximately 90%. Patients with lesions in the pelvis and humerus had local failure rates of 13% (7 of 54) and 21.4% (6 of 28), respectively. The treatment groups differed significantly in the incidence of pulmonary metastasis. Patients treated with the 4 drugs (regimen 1) ...
Singlet oxygen generators are multiphase flow chemical reactors used to generate energetic oxygen to be used as a fuel for chemical oxygen iodine lasers. In this paper, a theoretical model of the generator is presented along with its solutions over ranges of parameter space and oxygen maximizing optimizations. The singlet oxygen generator (SOG) is a low-pressure, multiphase flow chemical reactor that is used to produce molecular oxygen in an electronically excited state, i.e. singlet delta oxygen. The primary product of the reactor, the energetic oxygen, is used in a stage immediately succeeding the SOG to dissociate and energize iodine. The gas mixture including the iodine is accelerated to a supersonic speed and lased. Thus the SOG is the fuel generator for the chemical oxygen iodine laser (COIL). The COIL has important application for both military purposes--it was developed by the US Air Force in the 1970s--and, as the infrared beam is readily ...
The purpose of the invention is to improve a radiation receiver, consisting of a hollow body with an opening for the entry of radiation and a ceramic absorber situated in the hollow body, which absorbs the radiation energy entering through the opening, and emits it as thermal radiation to a heat medium, so that a higher efficiency can be achieved. According to the invention, the problem is solved by the fact that the absorber consists of ceramic material on the side towards the solar radiation, which has a low emission value and a high absorption value, and that the side of the absorber towards the heat medium has ceramic material of high emission value and low absorption value. This ensures that reradiation is prevented near the opening of the hollow body, and that the solar energy entering is largely absorbed in the hollow body.
The effects of fine-particle C, such as diesel soot, on the optical properties of urban haze in the visible wavelength range were explored to determine the dominant effects and to see if simple parameters (such as visual range in green) provide an adequate measure of these effects. It is known that fine-particle C absorbs more strongly in the blue than in the red, so that when it is mixed with a white pigment, the resulting gray can appear somewhat brown. The possibility of a similar effect in urban hazes was investigated, but found not to occur. When the sun is overhead, the near-horizon sky chromaticities caused by mixtures of fine-particle C and non-absorbing aerosol can also be produced by non-absorbing aerosols alone. It is shown that absorbing aerosol will darken the horizon sky, and a simple equation for the radiance of the horizon sky is derived. The effect of absorbing ...
In this work a study of simulation of the gamma graphic studies that are carried out in human esophagus in the Dept. of Nuclear Medicine of the 'Celestino Hernandez Robau Hospital of Santa Clara is presented. For the investigation tubular reactors were used and sting-response techniques with radioactive tracer of Technetium 99 metastable to a concentration of 1 mCi and several flows were applied. The distribution curves of residences times were obtained, those that respond to an equation of the type: Y = A + B exp (- exp((x-C)/D)) - ((x-C/D)+1). They were also carried out, optimizations studies of the doses of the radioactive to give to the patients from 1 mCi (that is the one used in studies) up to 0,5 mCi, and the influences on the obtained distributions of residence time were analyzed. It was confirmed the possibility to lower the doses with clear information of the signal. It was also carried out a simulation ...
Purpose: Reconstruction of organ doses of selected organs and tissues from radiographic settings and exposure data collected during chest X-ray examinations of children of various age groups performed in Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007. Materials and Method: The dosimetric data of all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 119 150 chest radiographs of all age groups. Reconstruction of organ doses in 40 organs and tissues in X-ray examinations of the chest was performed based on the conversion factor concept. Results: The radiation exposure of organs in projection radiography is determined by the exact site of the organs relative to the edges of the X-ray field and ...
The aim of this study is three folds: to compare the eight-channel phased-array and standard circularly polarized (CP) head coils in visualiazation of the intracranial vessels, to compare the three-dimentional (3D) time-of-flight (TOF) MR angiography (MRA) techniques, and to define the effects of parallel imaging in 3D TOF MRA. Fifteen healthy volunteers underwent 3D TOF MRA of the intracranial vessels using eight-channel phased-array and CP standard head coils. The following MRA techniques were obtained on each volunteer: (1) conventional 3D TOF MRA with magnetization transfer; (2) 3D TOF MRA with water excitation for background suppression; and (3) low-dose (0.5 ml) gadolinium-enhanced 3D TOF MRA with water excitation. Results are demonstrating that water excitation is a valuable background suppression technique, especially when applied with an eight-channel phased-array head coil. For central and proximal portions of the intracranial arteries, unenhanced TOF MRA ...
Thin-film solar cells on flexible, lightweight, space-qualified substrates provide an attractive approach to fabricating solar arrays with high mass-specific power. A polycrystalline chalcopyrite absorber layer is among the new generation of photovoltaic device technologies for thin film solar cells. At NASA Glenn Research Center we have focused on the development of new single-source precursors (SSPs) for deposition of semiconducting chalcopyrite materials onto lightweight, flexible substrates. We describe the syntheses and thermal modulation of SSPs via molecular engineering. Copper indium disulfide and related thin-film materials were deposited via aerosol-assisted chemical vapor deposition using SSPs. Processing and post-processing parameters were varied in order to modify morphology, stoichiometry, crystallography, electrical properties, and optical properties to optimize device quality. Growth at atmospheric pressure in a horizontal ...
This report summarizes the major activities conducted in the Chemical and Energy Research Section of the Chemical Technology Division at Oak Ridge National Laboratory (ORNL) during the period October--December 1997. The section conducts basic and applied research and development in chemical engineering, applied chemistry, and bioprocessing, with an emphasis on energy-driven technologies and advanced chemical separations for nuclear and waste applications. The report describes the various tasks performed within six major areas of research: Hot Cell Operations, Process Chemistry and Thermodynamics, Separations and Materials Synthesis, Fluid Structure and Properties, Biotechnology Research, and Molecular Studies. The name of a technical contact is included with each task described, and readers are encouraged to contact these individuals if they need additional information. Activities conducted within the area of Hot Cell Operations included efforts to optimize the ...
The production and characterisation of thin films made from molybdenum sulphide, molybdenum selenide, tungsten sulphide and tungsten selenide are described. The electronic properties of the thin films were examined by Hall measurements and by thermal sensors. For the MoSe[sub 2] films, the majority of the samples were n-conducting and p-conduction was only found for a few examples. All the other films (MoS[sub 2], WS[sub 2], WSe[sub 2]) were p-conducting. The electrical transport properties of the thin films are comparable to those of single crystals. With these thin films as absorber materials, it was possible for the first time to produce the polycrystalline solid n-ZnO/p-MoSe[sub 2], n-ZnO/WSe[sub 2], n-ZnO/WS[sub 2]- and n-ITO/WS[sub 2] solar cells. In spite of not yet optimized diode geometry (lateral build-up), a maximum short circuit current of I[sub SC] = 18 mA/cm[sup 2] was achieved for the MoSe[sub 2] diode. (orig.)
The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm{sup -3} or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant applications. Many of the design features and the end application itself set these TGS ...
The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm"-"3 or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant applications. Many of the design features and the end application itself set these TGS systems ...
To determine a suitable combination of X-ray filter and tube kilovoltage for Fuji Computed Radiography (FCR), provide better detection of pulmonary nodules, and reduce patient exposure, we compared observer performance with different X-ray filters and tube voltages. Radiographs were obtained with a copper filter backed by aluminium, with a tungsten filter backed by yttrium and aluminium, and with a lead filter backed by yttrium and aluminium, at both 100 kVp and 135 kVp. Observer performance in detecting simulated lung nodules, which were placed on the posterior aspect of a chest phantom, was compared using receiver operating characteristic (ROC) techniques for each combination of the X-ray filter and tube voltage. The results of the study indicated that (1) nodule detection was superior for the images obtained with 135 kVq as compared with 100 kVp; (2) approximately equal detection rates were obtained for the three X-ray filter sets, although results with the tungsten filter were ...
To determine a suitable combination of X-ray filter and tube kilovoltage for Fuji Computed Radiography (FCR), provide better detection of pulmonary nodules, and reduce patient exposure, we compared observer performance with different X-ray filters and tube voltages. Radiographs were obtained with a copper filter backed by aluminium, with a tungsten filter backed by yttrium and aluminium, and with a lead filter backed by yttrium and aluminium, at both 100 kVp and 135 kVp. Observer performance in detecting simulated lung nodules, which were placed on the posterior aspect of a chest phantom, was compared using receiver operating characteristic (ROC) techniques for each combination of the X-ray filter and tube voltage. The results of the study indicated that 1) nodule detection was superior for the images obtained with 135 kVq as compared with 100 kVp; 2) approximately equal detection rates were obtained for the three X-ray filter sets, although results with the tungsten filter were ...
Objective: To evaluate technical feasibility and acute and subacute radiotolerance of a self-expandable stent loaded with {sup 125}I seeds in the rabbit esophagus. Methods: A self-expandable stent designed for esophageal application was made of 0.16 mm nitinol wire and loaded with {sup 125}I seeds (CIAE-6711). Twenty-seven stents with three different radioactive dosages (n = 9 in each dosage group) were implanted in the esophagus of healthy rabbits, while nine stents alone were used as controls. The stents were perorally deployed into the esophagus under fluoroscopic guidance. Radiological follow-up included plain chest film, CT scan, and barium esophagography which were undertaken in all rabbits of each group at 2, 4, and 8 weeks, respectively, which were correlated to histopathological findings. The stented esophageal segments along with their adjacent tissues were harvested for histopathological examinations. Results: The stent was successfully deployed into the targeted esophageal ...
The differing susceptibility of individuals to the toxic effects of chronic lead exposure has never been fully understood. As the major intake of lead in the human is from food and beverages, any variation between individuals of the quantity of lead absorbed from the gut, and of the distribution and excretion of this lead, may account for the differences in individual susceptibility. The food and beverages themselves may have an influence, and to investigate their effects on absorption, distribution and excretion of lead, experiments were performed on normal subjects using a short lived radionuclide of lead, "2"0"3Pb, and instruments generally available in Nuclear Medicine. Lead absorption between different individuals showed a wide variation when "2"0"3Pb was taken as a single dose between meals. Minerals were found to be mainly responsible for affecting absorption when one subject ingested "2"0"3Pb in control meals from which one dietary ...
The mechanism of lead transport is presented, and especially the particular similarities or dissimilarities between lead and calcium in this process. The absorption of these metals was determined cockerels, raised on a commercial diet or on a specified diet, using in vivo ligated loop procedure. The dose administered into the loop contained 0.5 #mu#Ci "2"0"3Pb (and/or 0.1 #mu#Ci "4"7Ca), and 0.01 mM lead acetate (and/or mM CaCl_2) in 0.5 ml 0.15 M NaCl,pH 6.5. It was shown that lead is rapidly taken up by the mucosal tissue, and slowly transferred into the body, whereas less calcium is retained by the tissue and the transfer of calcium is many times as effective as that for lead. They appear to respond in a similar manner to a low calcium intake and vitamin D treatment. Increasing luminal stable lead concentration significantly reduced the percentage of radiolead significantly reduced the percentage of radiolead absorbed, but did not affect the ...
Natural radioactive materials under certain conditions can reach hazardous radiological levels. The natural radionuclide ("2"3"8U, "2"3"2Th, "4"0K) contents of rock samples at various locations in the North Tushki area were investigated using gamma-spectrometric analysis. Estimates of the measured radionuclide content have been made for the absorbeddose rate of gamma radiation. The equivalent radium (R_e_q) and the external hazard index (H_e_x) which resulted from the natural radionuclides in soil are also calculated and tabulated. The studied samples have been collected from various rock exposures in the North Tushki area. The distribution of major oxides, U and Th were studied. It is found that the enrichment and depletion of the major oxides are mainly due to the effect of hydrothermal alteration, which caused mobility of some major oxides, which increases some elements and decreases others. It is important to mention that the study area is ...
Two neutron emesis experiments were conducted at the Armed Forces Radiobiology Research Institute (AFRRI). In both experiments (described as Phase I and Phase II) the radiation dose required to cause emesis in 50% of subjects (ED50) was determined for both neutron reactor and gamma reactor source radiation. Emesis onset, offset and duration times post-exposure are reported. Neutrons were maximized from the reactor by passing the beam through a 15.25 cm (6 in.) thick lead wall to filter out gamma photons. Gamma rays were maximized by thermalizing neutrons in 30.5 cm (12 in.) of water, then absorbing the thermal neutrons in a gadolinium-cadmium shield. In Phase I, 28 dogs were exposed to radiation: 12 were exposed to gamma photons at the rate of 0.69 Gy/min and 16 were exposed to neutrons at 1.2 Gy/min. In Phase II, 58 dogs in 3 groups were exposed to radiation: 19 were exposed in the gamma group at 0.75 Gy/min, 20 were exposed in the undrugged ...
The transfer of 203Pb and/or 47Ca across the intestinal epithelium of the chick was investigated, with emphasis given to the functional role of cholecalciferol (vitamin D-3). 203Pb, after introduction in the intestinal lumen, is rapidly accumulated by the intestinal tissue, and only a fraction of 203Pb is translocated parenterally (absorbed). Cholecalciferol did not significantly affect the accumulation of 203Pb by intestinal tissue but did accelerate 203Pb movement across the basal-lateral membrane. In contrast, cholecalciferol both decreased 47Ca tissue levels and increased 47Ca absorption. In rachitic chicks, the rate of absorption of 203Pb was greater in the distal than in the proximal segments of the intestine; after cholecalciferol repletion, the degree of absorption in al segments was similar, indicting the order of cholecalciferol effectiveness as duodenum greater than or equal to jejunum greater than ileum. An acute dose of 1,25(OH)2D3 ...
The transfer of /sup 203/Pb and/or /sup 47/Ca across the intestinal epithelium of the chick was investigated, with emphasis given to the functional role of cholecalciferol (vitamin D-3). /sup 203/Pb, after introduction in the intestinal lumen, is rapidly accumulated by the intestinal tissue, and only a fraction of /sup 203/ Pb is translocated parenterally (absorbed). Cholecalciferol did not significantly affect the accumulation of /sup 203/Pb by intestinal tissue but did accelerate /sup 203/Pb movement across the basal-lateral membrane. In contrast, cholecalciferol both decreased /sup 47/Ca tissue levels and increased /sup 47/Ca absorption. In rachitic chicks, the rate of absorption of /sup 203/Pb was greater in the distal than in the proximal segments of the intestine; after cholecalciferol repletion, the degree of absorption in all segments was similar, indicating the order of cholecalciferol effectiveness as duodenum greater than or equal to jejunum > ileum. ...
The absorbeddose delivered to the patient in brachytherapy is directly proportional to the source strength in terms of the reference air-kerma rate (RAKR). Verification of this quantity by the hospitals is widely recognized as an important part of a quality assurance program. An external audit was performed on behalf of the Secondary Standard Dosimetry Laboratory at the Swedish Radiation Protection Authority (SSI). The aim was to investigate how accurately the source-strength in 192Ir brachytherapy is determined at Swedish hospitals. The SSI reference well-type ion chamber and calibrated equipment were used to measure the RAKR of an 192Ir source in each of the 14 Swedish afterloading units. Comparisons with values determined by vendors and hospitals were made. Agreement in values of RAKR as determined by SSI, hospitals and vendors were in all cases within the +-3% uncertainty (at a coverage factor of k=2), typically guaranteed by the vendors. ...
For the purpose of searching some effective absorbents of gaseous radioactive iodine, 16 substances considered as having an affinity for iodine were investigated with regular iodine and /sup 125/I. In a preliminary survey, only tetrathiafulvalene (TTF) was found to have satisfactory absorbing properties comparable to activated charcoal. A further detailed comparison of the properties between TTF and activated charcoal led us to the conclusion that the former has more preferable properties as absorbent of radioactive iodine than the latter in all points studied. The results are summarized as follows: (1) The absorption of iodine on TTF in atmosphere was about twice as much as that on activated charcoal. Desorption of iodine from saturatedly absorbed iodine on TTF was practically negligible except trace amount of initial desorption, while that on activated charcoal was considerable (3%/50h) even in the ...
A cooperative effort of the Center for Solar Energy and Hydrogen Research (ZSW) and Phototronics Solartechnik GmbH (PST) aimed at the transfer of highly efficient solar cells developed on a laboratory scale, to large-area thin-film solar modules suitable for production. This work was based on research and development at the Institute for Physical Electronics (IPE) of Stuttgart University and ZSW on one hand, and on the know-how of PST in regard to large-area module fabrication on the other hand. The various thin-film layers of the cells and modules comprize molybdenum as rear contact, copper-indium(gallium)-diselenide (CIGS) as absorber material, the combination of cadmium sulphide (CdS) and ZnO as window layer. To produce these layers on large areas (30x30 cm{sup 2}), equipment was constructed and procedures were developed. Monolithic series connection of cells, used in other thin-film technologies, was studied and optimized by suitable ...
This patent describes a process for removing carbon dioxide from a feed stream of natural gas having at least methane, ethane and heavier. It comprises: first, separating the feed stream in a first separator to form a first stream having substantially all of the propane and heavier hydrocarbons and carbon dioxide and ethane and a second stream, having methane, carbon dioxide and ethane; separating the second stream in a second separator into a stream of carbon dioxide product and a third stream having ethane, methane and carbon dioxide: mixing at least a portion of the third stream with a polar compound; stream after the mixing in an absorber; separating the vapor and liquid of the third stream after the mixing in an absorber; absorbing the remaining unabsorbed carbon dioxide in a lean portion of the polar compound in the absorber, the absorber carbon dioxide and ethane with the ...
The purpose and need for DOE to undertake the actions described in this document are to improve the efficiency of the Alternating Gradient Synchrotron (AGS) complex. Benefits would include optimization of the AGS scientific program, increased high-energy and nuclear physics experimentation, improved health and safety conditions for workers and users, reduced impact on the environment and the general public, energy conservation, decreased generation of hazardous and radioactive wastes, and completion of actions required to permit the AGS to be the injector to the Relativistic Heavy Ion Collider (RHIC)., Improved efficiency is defined as increasing the AGS`s capabilities to capture and accelerate the proton intensity transferred to the AGS from the AGS booster. Improved capture of beam intensity would reduce the beam losses which equate to lost scientific opportunity for study and increased potential for radiation doses to workers and the general ...
Self-assembled quantum dots (QDs) are envisioned as building blocks for realization of novel nanoelectronic devices, for which the site-selective growth is highly desirable. This thesis presents a successful route toward selective positioning of self-assembled InAs QDs on patterned GaAs surface by combination of in situ focused ion beam (FIB) implantation and molecular beam epitaxy (MBE) technology. First, a buffer layer of GaAs was grown by MBE before a square array of holes with a pitch of 1-2 #mu#m was fabricated by FIB implantation of Ga and In, ions respectively. Later, an in-situ annealing step followed by InAs deposition was performed. The InAs QDs were preferentially formed in the holes generated by FIB. The influence of ion dose, annealing parameters and InAs amount was investigated in this work. With optimized parameters, more than 50 % single dot occupancy per hole is achieved. Furthermore, the photoluminescence spectra from ...
Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons detected by the two detectors, respectively and the imaging quality of phantoms. Preliminary results showed ...
The main driver in ultra-shallow formation for the 65 nm technology node and beyond is to find solutions that both reduce boron transient enhanced diffusion and can be integrated in the CMOS process flow. To this end, many studies have recently focused on using co-doping techniques with fluorine and most recently with carbon. In most cases, one or both of these is co-implanted with a dopant specie in pre-amorphized silicon. In this work, we show a comparative study of fluorine or carbon co-implanted with low-energy boron to form source and drain extension junctions for PMOS devices. We will show that by a systematic optimization of germanium, boron, fluorine or carbon energies and doses, spike annealing technology can be extended to the 65 nm node. These results will be used to discuss how the different formed junctions offer potential solutions for either low-power or high-performance PMOS device fabrication.
A shock absorber mechanism and method for use on the leg structure of a jack-up offshore drilling rig is described. It is mounted on the bottom of each existing leg of a drilling rig and comprises a pointed piston member which is positioned on the bottom of the leg structure and projects downwards through the can/footing of the rig leg. The piston member is held in place by a resilient tension member which is designed to absorb shock forces during vertical/axial impact of the leg structure when contact is made with the ocean floor. (author).
Use of hydrogen absorbing alloys in various practical applications is always connected with the problem of production of starting alloys. The transition from laboratory samples to small-scale production involves the change of furnace and its operation mode and this has an effect on the preparation method of mixture of starting metal. Also, for some applications such as thermosorption compressors the exact values of thermodynamical parameters of reaction are needed. In the present work we present the results of investigation of series Laves phase hydrogen-absorbing alloys which can be promising in for use in different devices. 1 ref.
Full text: Thermoluminescence (TL) is a phenomenon of light emission caused by heating a pre-irradiated material. When ionizing radiation hits a TL material, electrons are freed from some atoms and moved in the material, leaving behind 'holes' of positive charge. Subsequently when the TL material is heated, the electrons and the 'holes' re-combine, and release the extra energy in the form of light. The light intensity can be measured, and related to the amount of energy initially absorbed through exposure to the ionizing radiation. In nineteen sixties thermoluminescence dosimeters (TLD) became popular for dosimetric applications in view of their small size, sensitivity and accuracy. Consequently, in early seventies, several countries started adopting of TLD for personnel monitoring. The idea of introducing TLD to replace the then prevalent film dosimeter for personnel monitoring in India was mooted and successfully implemented by Dr. K G Vohra. Limitations of ...
The design of the absorber blocks for internal and external dumping of the SPS proton beam is discussed. In addition, the external target stations for slow and fast extracted proton beams are described.
This paper presents the development and evaluation of field- controllable, semi-active magneto-rheological fluid (MRF) shock absorbers for a mountain bicycle. Recent trends in the bicycle industry show a movement towards semi-active suspension systems. Two new MRF dampers are designed and tested with the intent of being used on the front and rear suspension of a modern mountain bicycle. The MRF shock absorbers are designed to emulate the performance of the original equipment manufacturer shock absorbers in passive mode. Application of an input electric current to the MRF shock absorber causes a dramatic increase in the damping capacity. Procedures and results are presented for the design and experimental characterization of these MRF dampers.
This invention is an improved solar energy cavity receiver for exposing materials and components to high temperatures. The receiver includes a housing having an internal reflective surface defining a cavity and having an inlet for admitting solar radiation thereto. A photothermal absorber is positioned in the cavity to receive radiation from the inlet. A reflective baffle is positioned between the absorber and the inlet to severely restrict the re-radiation of energy through the inlet. The front surface of the baffle defines a narrow annulus with the internal reflective surface of the housing. The front surface of the baffle is contoured to reflect incoming radiation onto the internal surface of the housing, from which it is reflected through the annulus and onto the front surface of the absorber. The back surface of the baffle intercepts infrared radiation from the front of the absorber. With this ...
This invention is an improved solar energy cavity receiver for exposing materials and components to high temperatures. The receiver includes a housing having an internal reflective surface defining a cavity and having an inlet for admitting solar radiation thereto. A photothermal absorber is positioned in the cavity to receive radiation from the inlet. A reflective baffle is positioned between the absorber and the inlet to severely restrict the re-radiation of energy through the inlet. The front surface of the baffle defines a narrow annulus with the internal reflective surface of the housing. The front surface of the baffle is contoured to reflect incoming radiation onto the internal surface of the housing, from which it is reflected through the annulus and onto the front surface of the absorber. The back surface of the baffle intercepts infrared radiation from the front of the absorber. With this ...
An emergency shutdown system for high-temperature gas-cooled pebble-bed reactors is proposed in addition to the common absorber rod shutdown system. This system is based on the strongly absorbing effect of small boronated graphite spheres (called KLAK), which trickle in case of emergency by gravity from the top reflector into the reactor core. The inner reflector of the Siemens-Argonaut reactor was substituted by an assembly of spherical Arbeitsgemeinschaft Versuchsreaktor fuel elements, and the shutdown effect was examined by installing well-defined KLAK nests inside this assembly. The purpose was to develop and prove a calculational procedure for determining criticality values for assemblies of large fuel spheres and small absorbing spheres.
This invention is an improved solar energy cavity receiver for exposing materials and components to high temperatures. The receiver includes a housing having an internal reflective surface defining a cavity and having an inlet for admitting solar radiation thereto. A photothermal absorber is positiond in the cavity to receive radiation from the inlet. A reflective baffle is positioned between the absorber and the inlet to severely restrict the re-radiation of energy through the inlet. The front surface of the baffle defines a narrow annulus with the internal reflective surface of the housing. The front surface of the baffle is contoured to reflect incoming radiation onto the internal surface of the housing, from which it is reflected through the annulus and onto the front surface of the absorber. The back surface of the baffle intercepts radiation from the front of the absorber. With this arrangement, a ...
In the WWER-440 reactor the primary piping consists of six horizontal loops going radially from the pressure vessel, each loop having a horizontal steam generator. In this reactor type the relatively long primary piping with many curved sections requires special attention in order to successfully eliminate the consequences of the design basis accident. Emergency supports are located in appropriate places to restrict the movements of the pipe. Under normal conditions there is a gap of some centimeters between the pipe and a support so that in the pipe can be deformed freely under changing loads. This paper deals with those energy-absorbing structures used at the Loviisa Nuclear Power Plant for protection against impact loading. Places and circumstances where energy-absorbing structures are employed are specified. Development and design of impact absorber elements are discussed and impact tests are described. (Auth.).
The behaviour of the packaging materials under radiation field has a great importance in radiation processing, because, in most cases, they are finally responsible for the preservation of the beneficent changes achieved in irradiated products. For example, in radiation sterilisation and food irradiation, the packages must preserve the sterilisation, respectively the sanitisation. They must preserve also the physical barrier feature. The radiation effects on plastics were extensively studied in the last decades for nuclear industry and more recently for radiation processing. The two major effects of nuclear radiation on polymeric materials are the degradation and cross-linking. The degradation consists in breaking of macromolecules after interaction with nuclear particles, amplified by the free radicals which persist long periods, especially in crystalline polymers. Oxygen could penetrate the sample and interact with free radicals so that the degradation process continues after the ...
Microcapsules consisting of alginate and hyaluronic acid that can be decomposed by radiation are currently under development. In this study, the composition of the microcapsule material was optimized by changing the amounts of alginate and hyaluronic acid. Solutions of 0.025%, 0.05%, 0.1%, 0.2%, or 0.4% (wt./vol.) hyaluronic acid were mixed into a 0.2% alginate solution. To these mixtures, carboplatin (0.2 mmol) was added and the resulting material was used for the capsule preparation. The capsules were prepared by spraying the material into a CaCl{sub 2} solution (0.34 mol/l) using a microatomizer. These capsules were irradiated by a single dose of 2, 5, or 10 Gy {sup 60}Co {gamma}-ray radiation. Immediately after irradiation, the releasing of core content of microcapsule was determined, using a micro particle induced X-ray emission (PIXE) camera. The average diameter of the microcapsules was 22.3 {+-} 3.3 {mu}m, and that of the liquid core ...
The concentrations of uranium, arsenic, and radium remain well below the maximum permissible values of < 0.1 mg/l (uranium), < 0.1 mg/l (arsenic) and < 100 mBq/l (radium) due to two separation stages with barium sulfate and GoPur 3000 precipitation and due to iron hydroxide/iron arsenate precipitation. The radioactive arsenates can be separated from the toxic ones by separating the sludge which is analyzed. Processing of radioactive sludges leaves reusable GoPur 3000, sulfuric solutions which contain uranium or solutions which contain carbonate, and radioactive barium sulfate whose radiation intensity of 12 mBq/g is due to the presence of radium. The sludge produced contains adsorbed salts in addition to the dosed chemicals (floated sludges: 40 g/m"3, iron sludges < 20 g/m"3). A solids content < 100 g/m"3 can be selected for both sludge portions. Static-mixer chemicals dosing and technical improvements of the tubular reactor are ...
Several shield options were analyzed for the ITER conceptual design to minimize the nuclear responses in the toroidal field (TF) coils. The total nuclear heating in the physics phase and the insulator dose in the technology phase are the most critical parameters in the design process. The first shield option has type 316 stainless steel and water shielding material. Steel and water also serve as structural material and coolant, respectively. The second option is similar to the first except that borated water is used instead of ordinary water. The other two options include a small layer of lead or boron carbide (B{sub 4}C) at the back of the shield. The last three shield options were considered to reduce the nuclear heating in the toroidal field coils relative to the steel/water shield. An optimization process was performed taking into consideration the thermal-hydraulics and the engineering requirements to define the shield configuration. A ...
For the Convolution, Superposition and Monte Carlo methods, energy spectrum data is an essential parameter. Especially, by using Monte Carlo method, if the adequate properties of electrons are set, complex energy spectrum data can be calculated by simple input. However, adjustment of the property of electrons incident on the target of linear accelerator is time-consuming procedure. To cover the difference of many accelerators, it is important how we obtain accurate energy spectrum by simple methods. Especially, the total accuracy of dose calculation depends on the agreement of measured and calculated percentage depth dose (PDD) and off-axis ratio (OAR). Thus, a simple method for the determination of the simulation parameters was considered. To reduce the adjustment procedure, we selected values of important three parameters, which were the mean energy of the input electron beam, the energy distribution of the input electron beam and the radial ...
The proton beam has a unique advantage over the electron and photon beams in that it can give very high radiation dose to the tumor volume, while effectively sparing the neighboring healthy tissue and organs. For the clinical application of the proton beam, it is very important to confirm the location of the proton beam in the patient, preferentially during the treatment. It has been suggested that the range of the proton beam in the patient can be determined by measuring prompt gammas from the proton beam passage. Recently, a prototype prompt-gamma scanning system has been constructed and tested using experimental and therapeutic proton beams. The measurement results for the proton beams of 70 . 230 MeV showed that a clear correlation exists between the distribution of the prompt gammas and the proton beam range. The scanning method, however, is not suitable for the upcoming 'spot scanning' technique. The 'spot scanning' ...
Purpose: To describe the technique of DE MDCT colonoscopy and to assess its feasibility. Materials and Methods: 8 patients were scanned with DSCT with a DE scan protocol and dose modulation software. Analysis was performed using dedicated DE software. Prone non-contrast images and DE supine images after contrast injection were obtained. Results: DE colonoscopic images were successfully obtained in 7 patients, but the FOV did not cover all colonic segments in 1 patient, thus resulting in a technical success rate was 87.5%. Streak artifacts were present in the pelvic region in 2 patients. Virtual unenhanced images and iodine map images were obtained for all patients. In 1 patient a polypoid non-enhancing structure was noted on the iodine map, and conventional colonoscopy revealed impacted stool. Enhancing rectal cancer in 1 patient was correctly shown on the iodine map. Iodine maps helped to differentiate stool fragments/retained fluid by the absence of enhancement ...
Method for description of X-ray radiation dose distribution based on semiempirical description of dose fields is suggested. At that dose field description parameters can be easily individualized for concrete X-ray device.
Examples are used to demonstrate that a shift in the point of emphasis is necessary with regard to radiation hazard in medicinal X-ray diagnosis. The parameters employed in this study to calculate somatic dose (SD) and somatically significant dose (SSD) m...
The fundamental recommendations of the ICRP issued in its publication of 1990 stipulate the general principle of performance of dose measurements at regular intervals in the field of diagnostic radiology, for the purpose of equipment performance checking and optimization of radiological protection. In response to this requirement, the Federal Ministry, in cooperation with experts and the competent supervising authorities, has issued an order to install dose-area-product meters in angiographic examination systems, imaging systems and fluoroscopic screen devices primarily used for examining infants and children up to the age of 12. This is done in response to reported cases of adverse effects of radiation exposure and the high priority given to radiological protection in the examination of infants and children. In 1992, an expert group was convened to discuss and elaborate instructions for including ...
Dosimetric studies in 80 patients examined with the tomographic device 'Somatom' are reported. The gonad doses are compared to those of conventional radiographic techniques.
In the present study an estimate is made of the malignancy significant dose from external beam radiotherapy in New Zealand utilizing data obtained in a survey conducted in 1975. This survey had been designed to assess genetically significant dose. A weighted effective dose equivalent is derived from the malignancy significant dose for direct comparison with mean per capita effective dose equivalents arising from other sources of radiation. 14 refs., 1 fig., 8 tabs.
The use of absorbable polyglactin 910 mesh (Vicryl) is described in a case of Ewing's sarcoma of the pelvis. An operation was performed to hold the small bowel and colon out of the pelvis for a temporary period during which radical radiotherapy was delivered. The mesh allowed the temporary displacement of bowel and obviated bowel radiation morbidity. (author).
One of the main disadvantages of solar air collectors in practical applications is their relatively low efficiency. In this experimental investigation, the shape and arrangement of absorber surfaces of the collectors were reorganized to provide better heat transfer surfaces suitable for the passive heat transfer augmentation techniques. The performance of such solar air collectors with staggered absorber sheets was tested. The experimental results show that it is possible to provide 10 to 25% enhancement in the efficiency compared to the conventional solar air collectors. (authors)
The brochure reports on the construction and method of operation of heat pumps: - Efficiency and temperature difference - output figure - circuit processes - saving of primary energy - monovalent and bivalent plants - absorber, earth collectors - heat recovery. (HW) [Deutsch] Die Broschuere berichtet ueber den Aufbau und die Wirkungsweise von Waermepumpen: - Wirkungsgrad und Temperaturdifferenz - Leistungszahl - Kreisprozesse - Einsparung von Primaerenergie - monovalente und bivalente Anlagen - Absorber, Erdkollektoren - Waermerueckgewinnung. (HW)
In studying the absorption of carbon dioxide by absorbents impregnated with alkanol amines, researchers used a laboratory-scale packed column to determine the overall gas-phase mass-transfer coefficients and enhancement factors. A model derived for the mechanism of the chemical reaction taking place in the interfacial layer accounts for the effect of the reaction upon the absorption rate better than other models.
The concept of a multi-cavity volumetric solar receiver is very attractive for the profitability of certain of its characteristics such as high efficiency and economy. The absorber is based on a pack of small ceramic cavities which intercept and absorb the inherent high solar flux reflected from an array of mirrors. Atmospheric air acts as a coolant medium when it is drawn through the pack. A model for an overall heat transfer performance of the receiver is given and numerically solved.
LEDF(Large Equipment Dismantling Facility) is the solid waste processing technology development facility that carries out high-volume reduction and low dosage processing. The high-volume reduction processing of the high dose {alpha}-waste configured with combustible waste, pvc and rubber, spent ion exchange resin, and noncombustible waste have been planned the incinerating and melting facility using the in-can type high frequency induction heating in LEDF. This test is intended to clarify the design data. It was confirmed that the incinerating and melting performance, molten solid properties and exhaust gas processing performance with pilot testing equipment and bench scale equipment. The result of this test are as follows. 1. Processing speed is 6.7 kg/h for the combustible waste, 13.0 kg/h for the ion exchange resin, and 30.0 kg/h for the noncombustible waste. For above optimum processing conditions are as follows. Operating temperature is 1000degC for the ...
In Tarapur Atomic Power Station unit-3 and 4, which is 540 MWe pressurized heavy water reactor, tritium is produced in primary heat transport system and moderator system. Tritium is a major contributor to the internal dose. Internal dose contributes about 30% of the collective dose. Internal dose monitoring and its control are important to control the collective dose. Estimation of internal dose is done by analysis of bioassay samples of radiation workers. In a month, about 7000 bioassay samples are analysed for the internal dose assessment during normal operation, and about 12000 during the biennial shut down of the reactor. To enhance the sample preparation and counting performance, minimize the entry errors and reduce the processing time, barcode based label generation system was developed for the internal dose ...
In most previous studies of topology optimization, commercial programs, such as Optistruct, ANSYS, and MSC Patran, usually were used during implementation. Such commercial programs are not easy to use and entail time and cost. In addition, it is difficult to confirm results with reference to individual stages of optimization. For addressing this disadvantage, a topology optimization program, which is based on the C language, is developed in this study. This is a very convenient and powerful program for users to conduct topology optimization by using all density methods and homogenization methods in compliance with the methodology. For verifying the developed program, first of all, topology optimization was implemented by using density methods to evaluate the strain energy density of a cant...
An almost linear optimization problem of importance in vibration isolation has been identified and algorithms were developed to minimize the forced vibrational response of structural systems. The constraints can be either displacements of accelerations. T...
BackgroundPrior research links optimism to physical health, but the strength of the association has not been systematically evaluated.PurposeFull Text Available
This paper presents a set of heuristics useful for optimal design of heat-exchange networks and integrated heat and power systems. These heuristics consolidate other approaches reported in the literature in a formalism useful for design purposes.
Sep 18, 2009 ... It is proposed to develop desensitized optimal filtering ... in robust and/or adaptive generalized Kalman and Sigma-Point filters for ...
The Effective Dose Equivalent Concept defined by the International Commission on Radiological Protection in 1977 considers the risk from irradiation including both hereditary and somatic effects. This paper will deal with the definition of a concept for somatic effects only, the somatically significant dose equivalent. This is defined as the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by various individuals. The somatically effective dose equivalent for a particular radiopharmaceutical is the weighted sum of the average dose equivalent to various organs. The dose equivalent to various organs can be derived from an extended MIRD formalism also considering the rest of body excluding the source ...
The Effective Dose Equivalent Concept defined by the International Commission on Radiological Protection in 1977 considers the risk from irradiation including both hereditary and somatic effects. This paper will deal with the definition of a concept for somatic effects only, the somatically significant dose equivalent. This is defined as the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by various individuals. The somatically effective dose equivalent for a particular radiopharmaceutical is the weighted sum of the average dose equivalent to various organs. The dose equivalent to various organs can be derived from an extended MIRD formalism also considering the rest of body excluding the source ...
A survey to determine the annual genetically significant dose and mean bone-marrow dose to the Australian population from radiological procedures has been undertaken. For diagnostic radiology the following were carried out: determination of the frequency of a procedure; measurement of patient doses using TLD and processing of data and calculation of gonadal and bone-marrow doses.
In conveyor type irradiators, the movement of conveyor and the product boxes is not there until the source is fully in the irradiation position. In case the conveyor system fails the source must automatically be returned to its shielded storage vault. The dose received by the product during the movement of the source from or to the shield becomes significant if the total dose to be received by the product is small. A study has been carried out for evaluating the transient dose received by onions in the POTON irradiator. The results of the study are discussed in this paper. (author)
Objective: To develop a computerized method of internal dose estimation on radiation protection. Methods: Based on MIRD mathematic model of the organs and by means of the programming language of MS Visual Basic 6.0, a computer program of dose estimation in internal radiation was developed for radiation protection. Results: The computerized method of dose estimation for internal radiation was completed. Conclusions: This computerized method is very convenient for internal radiation dose estimation of several aspects. It can also be used in radiation accident. (authors)
We have developed a low-temperature particle detector that uses a novel quasiparticle trapping mechanism to funnel athermal phonon energy from an 80 mg Ge absorber into a 1.6 mg doped Ge thermistor via a superconducting Al film. We report on pulse height spectra obtained at 320 mK by scanning a {sup 241}Am alpha source along the device, and show that up to 20% of the energy deposited in the Ge absorber by a 5.5 MeV alpha particle interaction can be collected into a thermistor via quasiparticle trapping. We show that this device is sensitive to the position of an alpha particle interaction in the Ge absorber for interaction distances of up to 5 mm from a quasiparticle trap.
Objective: Pretargeting is the concept that combines optimal delivery of the antibody and rapid capture and elimination of the radioactivity. In this study, we evaluated the potential of antibody pretargeting to enable the tumor-targeting {sup 212}Pb for in vivo generation of {sup 212}Bi for {alpha} particle radiotherapy. Methods: The {sup 212}Pb/{sup 212}Bi chelate of DOTA-biotin, as well as their {gamma}-emitting analogues, {sup 203}Pb and {sup 205}Bi, was prepared and characterized. The radiolabeled compounds were injected in animals for evaluation of tumor targeting and normal tissue uptake and retention. In the pretargeting protocol, injection of 400 {mu}g of NR-LU-10 antibody-streptavidin conjugate was given at t=0 h, then 100 {mu}g of N-acetyl-galatosamine-biotin clearing agent was injected at t=20-24 h; finally, 1 {mu}g of {sup 212}Pb/{sup 212}Bi-DOTA-biotin was injected 6 h later. Results: Both {sup 203}Pb and {sup 205}Bi-DOTA-biotin were stable for at ...
An irradiation head with sample holders is described and measurement geometry is reported. Measurements were made for optimizing the distance between the source and the sample and for optimizing the sample diameter. The optimal distance between the source and the sample does not depend on the collimator diameter. The sample diameter should not exceed 30 - 35 mm. Sensitivity and detection limits were determined for Zn, Pb and Br and calibration curves were plotted. (M.D.) 6 figs., 2 tabs., 4 refs.
... been possible to prove the existence and uniqueness of a classical solution which tends to the well-known solution of the Stefan problem as the ...
... Note that the terminal ... Probability and Statistics with Reliability, Queueing, and Computer ... Weiss, G., "Stochastic Bounds on Distributions of Optimal ...
Nature-inspired algorithms are among the most powerful algorithms for optimization. This paper intends to provide a detailed description of a new Firefly Algorithm (FA) for multimodal optimization applications. We will compare the proposed firefly algorithm with other metaheuristic algorithms such as particle swarm optimization (PSO). Simulations and results indicate that the proposed firefly algorithm is superior to existing metaheuristic algorithms. Finally we will discuss its applications and implications for further research.
Two-dimensional generalization of the original peak finding algorithm suggested earlier is given. The ideology of the algorithm emerged from the well known quantum mechanical tunneling property which enables small bodies to penetrate through narrow potential barriers. We further merge this ``quantum'' ideology with the philosophy of Particle Swarm Optimization to get the global optimization algorithm which can be called Quantum Swarm Optimization. The functionality of the newborn algorithm is tested on some benchmark optimization problems.
A brief description of the physical process of dose enhancement effects produced by X-ray radiation on materials is given, with emphasis on the influence on electronic devices. The damages caused by X-ray radiation dose enhancement is more serious than that of #gamma#-ray with higher energy.
The aim of this research work has been the estimation of the stochastic risk for five barium examinations. The sample was the population attending the Radiological Service of the 'Nuestra Senora de la Victoria' University Hospital, who had been treated with some barium examinations, set in five different groups: oesophagus tract, oesophagus-gastric-duodenal tract, intestinal tract, enteroclysis and double enema. To estimate the stochastic risk, it is necessary to know the organ dose. This can be calculated from the dose-area product which allows us to determine the effective dose using software. The dose-area product is the most suitable quantity to measure in these types of examination. We have evaluated the contribution that each procedure provides to the genetically significant dose, somatically significant dose, collective effective ...
Dose reconstruction is a process that re-creates the treatment-time dose deposited in a patient provided there is knowledge of the delivered energy fluence and the patient's anatomy at the time of treatment. A method for reconstructing dose is presented. The process starts with delivery verification, in which the incident energy fluence from a treatment is computed using the exit detector signal and a transfer matrix to convert the detector signal to energy fluence. With the verified energy fluence and a CT image of the patient in the treatment position, the treatment-time dose distribution is computed using any model-based algorithm such as convolution/superposition or Monte Carlo. The accuracy of dose reconstruction and the ability of the process to reveal delivery errors are presented. Regarding accuracy, a reconstructed dose distribution was compared with a ...
Experiments were conducted to determine the dose response of rat bladder urothelium to a range of different single and fractionated intravesicular doses of the carcinogen, N-methyl-N-nitrosourea (MNU)....Full Text Available
The risks to human health from small doses of ionizing radiation raise questions which remain largely unanswered. This paper begins by explaining the historical background to this subject; it goes on to discuss recent developments and concludes with a personal view of the dose-reponse relationship. (author).
The risks to human health from small doses of ionizing radiation raise questions which remain largely unanswered. This paper begins by explaining the historical background to this subject; it goes on to discuss recent developments and concludes with a personal view of the dose-reponse relationship. (author).
Purpose:To investigate the clinical usage of dose verification of Helical Tomotherapy plans by using 2D-array ion chambers, and to develop an efficient way to validate the dose delivered...Full Text Available
An optimization of fuel bundle geometry using the subchannel code ASSERT is performed in support of Candu fuel design to enhance the thermohydraulics performance. The new bundle design is based on a reference CANFLEX bundle with changes to the centre and inner-ring element diameters and pitch-circle diameters (PCDs) of various element rings. Different methods of varying the PCDs for reaching the optimized geometry are considered in an attempt to minimize the optimization effort. The optimized geometry in the present analysis is the one that maximizes the dryout power and that has simultaneous CHF (critical heat flux) initiation involving more than one subchannel rings. (authors)
A systematic optimization method of choosing the weighting matrix in linear optimal control system design, under the conditions of prespecified closed-loop dominant eigenvalue locations and feedback gain limit constraints, is presented in this paper. Studies show that with the proposed method one can obtain the desired weighting matrix very quickly and conveniently without the heavy burden of choosing a suitable weighting matrix by trail and error. This method can also easily achieve a reduced-order feedback control system. The linear optimal power system stabilizer designed by using the proposed method produces very good performance.
The advent of rapid, reliable and cheap computing power over the last decades has transformed many, if not most, fields of science and engineering. The multidisciplinary field of optimization is no exception. First of all, with fast computers, researchers and engineers can apply classical optimization methods to problems of larger and larger size. In addition, however, researchers have developed a host of new optimization algorithms that operate in a rather different way than the classical ones, and that allow practitioners to attack optimization problems where the classical methods are either
Using nitrogen-13 initial measurements have been made of rumen ammonia-nitrogen pool size and turnover, and rate of incorporation of ammonia into microbial protein. It is also feasible to measure the rate of incorporation of absorbed ammonia into urea and the appearance of label in saliva.
The Neutron Radiography Reactor (NRAD) operated by Argonne National Laboratory is described in this paper. NRAD was designed to allow radiography of highly absorbing reactor fuel assemblies in the vertical position on the routine basis. 7 figs.
The Bureau of Mines performed chemical research to elaborate details of sulfur chemistry pertaining to the citrate flue gas desulfurization process in which sulfur dioxide (SO2), absorbed (as bisulfite ion) in a buffered sodium citrate solution, is reduce...
Trace gas molecules absorb specific wavelengths of incoming solar ... These data(with information collected from similar experiments carried on balloons, rockets, ... The ATMOS sensor instrumentis a state-of-the-art version of a 19th century ...
The Fast Flux Test Facility (FFTF) interim examination and maintenance (IEM) cell is used for the remote disassembly of irradiated fuel and material experiments. The absorber open-test assembly (AOTA) is a 12-m (40-ft)-long instrumented absorber (control-rod-material) test assembly. Its primary purpose is to characterize the FFTF control-rod-material reaction rate during reactor operation. Instrumentation allowed temperature and pressure measurements at various locations in several absorber pins during reactor operation. After residing several months in the reactor, the assembly was transferred to the IEM cell by the closed-loop ex-vessel machine (CLEM) for separation of the irradiated portion of the experiment from the instrument stalk. After separation, the 3.6-m (12-ft)-long assembly was processed through the sodium removal system and shipped off-site for examination. This success allowed the timely completion of a major ...
The A(..pi../sup +/,/sup 3/He)B reaction near threshold is studied in a model where the pion is absorbed by an /sup 4/He constituent of the target nucleus. The predictions of this model using harmonic oscillator cluster wave functions agree semi-quantitatively with the experimental data on the inverse reaction.
Mist eliminators for flue gas desulphurisation units remove liquid droplets entrained in the flue gas leaving the SO/sub 2/-absorber vessels. The commercial designs currently available are described.
High-purity and doped GaAs films have been grown by Liquid-phase epitaxy (LPE) for development of a blocked impurity band (BIB) detector for far-infrared radiation. The film growth process developed has resulted in the capability to grow GaAs with a net active impurity concentration below 1 x 10{sup 13} cm{sup -3}, ideal for the blocking layer of the BIB detector. The growth of n-type LPE GaAs films with donor concentrations below the metal-insulator transition, as required for the absorbing layer of a BIB detector, has been achieved. The control of the donor concentration, however, was found to be insufficient for detector production. The growth by LPE of a high-purity film onto a commercially grown vapor-phase epitaxial (VPE) n-type GaAs doped absorbing layer resulted in a BIB device that showed a significant reduction in the low-temperature dark current compared to the absorbing layer only. Extended optical response was ...
A prototype detector based on the inclined absorber layer principle is introduced. For the Liquids Reflectometer at the Spallation Neutron Source, it is shown to be a significant improvement over its current detector, which imposes an instantaneous count rate limitation of 50 kcps.
Photon migration provides sensitive tissue oximetry in which the optical pathlength is known. Phase array gives the precise location of a subnanomolar amount of hidden absorber in highly scattering medium. PMID:8079713
Only half of the carbon dioxide produced by burning fossil fuels stays in the atmosphere. It is thought that the oceans absorb the rest. To understand the world's climate it is necessary to know how the atmosphere, ocean and biosphere interact.
A process is described for removing carbon dioxide from a feed stream of natural gas, having at least methane, ethane and heavier hydrocarbon, comprising: separating the feed stream in a first separator to form a first stream, having substantially all of the propane and heavier hydrocarbons and carbon dioxide and ethane, and a second stream, having methane, carbon dioxide and ethane; mixing the second stream with a polar compound to form a third stream; separating the vapor and liquid of the third stream in the bottom portion of an absorber; absorbing carbon dioxide and ethane from the separated vapor of Step C in a lean portion of the polar compound in the absorber, the absorber carbon dioxide and ethane forming a fourth stream; separating the ethane from the polar compound and carbon dioxide in a separator; separating the first stream in a third separator to separate the propane and heavier ...
Tachyons fired into and absorbed by rotating black holes can violate the second and third laws of black hole physics. It is suggested that apparent break-downs of these laws in astrophysical black holes can indicate the existence of cosmic tachyons. (author).
Gun barrel vibrations lead to dispersion in the shot patterns. Thus, reducing these vibrations should lead to increased accuracy. Since the muzzle is the anti-node for all vibration modes and its vibrations have the greatest effect on shot dispersion, it ...
It is answered to a previous letter by Basano, and shown that the difficulties met by that author within ''Extended relativity'' do not exist, but are due to the erroneous assumption that a certain condition for tachyons to be absorbed by a macro-object is sufficient (whilst it is only a necessary one).
INTRODUCTIONCutiplast (absorbent perforated dressing with adhesive border; Smith & Nephew) is commonly used following orthopaedic operation, but complications of its use...Full Text Available
Organ and tissue doses and integral doses in patients due to diagnostic x-ray examinations of the chest and of the head will be presented. These data have been obtained by measuring the dose distributions in man phantoms by LiF-dosimetry. The data will be compared with data obtained by Monte-Carlo calculations. To obtain average organ doses for a special type of examination for the population or for a specified subpopulation in the variation of the exposure, data due to the different techniques used by the different radiologists has to be known. Such data will be presented. The results of the investigation will be discussed in connection with the concept of the 'somatic significant.
nsive neutron-absorbing bricks from commercially available CaB/sub 6/ powder. The bricks are 2 x 3 x 5 in., and are strong enough to withstand normal handling. They last indefinitely; the ones described are now 7 years old, used and stored under normal room temperatures and humidities. The procedure is to make a thick, dry mud with the powder and water, followed by compression in a mold at pressures of about 1 ton/in./sup 2/ or more. The bricks are then baked for 2 hours or longer at a temperature of about 750 deg C. (auth)
This dissertation deals with membrane gas absorption in the application of CO{sub 2} removal by aqueous alkanolamines, using microporous PTFE hollow fiber membranes. A new lab-scale apparatus was constructed and an extensive experimental study executed to determine the performance of the membrane gas absorber, with aqueous solutions of monoethanolamine (MEA) and methyldiethanolamine (MDEA) as absorbents. The important operation parameters CO{sub 2} partial pressure, gas velocity, liquid velocity, temperature and liquid CO{sub 2} loading were systematically varied within the range typically experienced in a process for exhaust gas CO{sub 2}-removal
The purpose of this study is to explain the unplanned longitudinal dose modulations that appear in helical tomotherapy (HT) dose distributions in the presence of irregular patient breathing....Full Text Available
To develop a work in an area with high radiation, it requires of a detailed knowledge of the surroundings work, a communication and effective vision, a near dosimetric control. In a work where the spaces variables and reduced accesses exist, noise that hinders the communication, defendant operative condition, radiation field and taking of decision, it is necessary to have tools that allow a total control of the environment to make opportune and effective decisions, there where the task is developed. Under this elementary concept, it was developed in the Laguna Verde Central a project that it allowed a mechanism, interactive of control in spaces complex; to see, to hear, to speak, to measure. This concept takes to the creation of an equipped system with closed circuit of television, wireless communication systems, tele dosimetry wireless systems, VHS and DVD recording equipment, uninterrupted energy units. The system requires of an electric power socket, and the installation of two ...
Many thermoluminescent materials has been developed and used for photon personal dosimetry but no one has all desired characteristics alone. These characteristics include robustness, high sensitivity, energy photon independence, large range of photon energy detection, good reproducibility, small fading and simple glow curve with peaks above 150 deg C. Calcium Sulfate Dysprosium doped (CaSO{sub 4}:Dy) phosphor Thermoluminescent Dosimeter (TLD) has been used by many laboratories, mainly in Brazil and India. Another interesting phosphor is Calcium Fluoride (CaF{sub 2}). These phosphor advantages begin to be more required and its disadvantages have became more apparent, in a global market more and more competitive. These phosphors are used in environmental and area monitoring, once they present more sensibility than other phosphors, like LiF:Mg. Theirs mainly disadvantage is a strong energetic dependence response, which must be corrected for theirs application in the field, where photon ...
Purpose: To evaluate the outcomes of patients with Ewing's sarcoma family of tumors (ESFT) treated with modern radiotherapy techniques with MRI along with optimal chemotherapy. Methods and Materials: The records of all 60 patients with ESFT who received radiation to the primary site between 1990 and 2004 were reviewed. All patients received chemotherapy, including vincristine, doxorubicin, cyclophosphamide, ifosfamide, and etoposide. Radiation was used as the sole modality for local control in 31 patients and was given either before (n = 3) or after surgical resection (n = 26) in the remainder. All patients had MRI and CT scan-based treatment planning, and 43% received intensity-modulated radiation therapy. Radiation doses ranged from 30 Gy to 60 Gy (median, 51 Gy), and 35% received hyperfractionated radiotherapy. Results: Median age was 16 years (range, 2-40 years). Because of selection bias for radiotherapy, the majority of primary tumors ...
The implementation of a three-dimensional conformal radiotherapy facility in the radiotherapy department of the Heinrich Heine University is described. Complex radiotherapy techniques with commercially available networked systems are introduced to improve clinical work. Over 18 month we have gained clinical experience with a PHILIPS Multileaf Collimator (MLC) mounted on a SL 25 linear accelerator. For a limited period the MLC was used as a conventional blocking device. The standard MLC-shapes are controlled with a stand-alone computer system. In addition, a three-dimensional treatment planning system (3-D-TPS / TMS-Radix, Helax AB) based on convolution/superposition algorithms was recently installed. Treatment optimization is achieved using static field arrangements with complete volumetric computerized tomographic patient data for 3-D-TPS. Conformal adaptation of the 95%-isodose to the Planning Target Volume (PTV, ICRU 50) results in MLC-field-shaping concerning ...
We present FIB-lithography methods for rapid and cost-effective prototyping of metal structures covering the deep-submicron- to the millimeter-range in a single lithography cycle. Focused ion beam (FIB) systems are widely used in semiconductor industry and research facilities for both analytical testing and prototyping. A typical application is to apply electrical contact to micron-sized sensors/particles by FIB induced metal deposition. However, as for E-beam lithography, patterning times for large area bonding pads are unacceptably long, resulting in cost-intensive prototyping. In this work, we optimized FIB lithography processing for negative and positive imaging mode to form metallic structures for large-areas down do the sub-100 nm range. For negative lithography features are defined by implanting Ga"+-ions into a commercial photo resist, without affecting the underlying structures by impinging ions. The structures are highly suitable for following lift-off ...
A vendor glass formulation study was carried out at Pacific Northwest Laboratory (PNL), supporting the Phase I and Phase II melter vendor testing activities for Westinghouse Hanford Company. This study is built upon the LLW glass optimization effort that will be described in a separate report. For Phase I vendor melter testing, six glass formulations were developed at PNL and additional were developed by Phase I vendors. All the doses were characterized in terms of viscosity and chemical durability by the 7-day Product Consistency Test. Twelve Phase II glass formulations (see Tables 3.5 and 3.6) were developed to accommodate 2.5 wt% P{sub 2}O{sub 5} and 1.0 wt% S0{sub 3} without significant processing problems. These levels of P{sub 2}O{sub 5} and SO{sub 3} are expected to be the highest possible concentrations from Hanford Site LLW streams at 25 wt% waste loading in glass. The Phase H compositions formulated were 6 to 23 times more durable ...
Large-scale field tracer experiments have been conducted on Ulchin, Wolsung and Daeduk sites for the purpose of validating FADAS and of analyzing the environmental characteristics around the nuclear sites. The most influential factor in atmospheric dispersion is the meteorological condition. During the experiment, meteorological data were measured on the release point and the selected positions among sampling points. Once radioactive materials are released to the atmosphere, members of public may be exposed through the environmental media such as air, soil and foods. Therefore, to protect the public, adequate countermeasures should be taken at due time for those exposure pathways. both processes, of justification and optimization are applied to a countermeasure simultaneously for decision-making. The work scope of Biological research for the radiation protection had contained the search of biological microanalytic methods for assessing the health effect by ...
The hexavalent chromium, Cr(VI), biosorption by raw and acid-treated Oedogonium hatei were studied from aqueous solutions. Batch experiments were conducted to determine the biosorption properties of the biomass. The optimum conditions of biosorption were found to be: a biomass dose of 0.8 g/L, contact time of 110 min, pH and temperature 2.0 and 318 K respectively. Both Langmuir and Freundlich isotherm equations could fit the equilibrium data. Under the optimal conditions, the biosorption capacities of the raw and acid-treated algae were 31 and 35.2 mg Cr(VI) per g of dry adsorbent, respectively. Thermodynamic parameters showed that the adsorption of Cr(VI) onto algal biomass was feasible, spontaneous and endothermic under studied conditions. The pseudo-first-order kinetic model adequately describe the kinetic data in comparison to second-order model and the process involving rate-controlling step is much complex involving both boundary layer ...
Boron Neutron Capture Therapy (BNCT) is a promising binary treatment modality for high-grade primary brain tumors (glioblastoma multiforme, GM) and other cancers. BNCT employs a boron-10 containing compound that preferentially accumulates in the cancer cells in the brain. Upon neutron capture by {sup 10}B energetic alpha particles and triton released at the absorption site kill the cancer cell. In order to gain penetration depth in the brain Fairchild proposed, for this purpose, the use of energetic epithermal neutrons at about 10 keV. Phase I/II clinical trials of BNCT for GM are underway at the Brookhaven Medical Research Reactor (BMRR) and at the MIT Reactor, using these nuclear reactors as the source for epithermal neutrons. In light of the limitations of new reactor installations, e.g. cost, safety and licensing, and limited capability for modulating the reactor based neutron beam energy spectra alternative neutron sources are being contemplated for wider implementation of this ...
This paper describes a study of comparison of global and one-dimensional local optimization methods to operating system scheduler tuning. The operating system scheduler we use is the Linux 2.6.23 Completely Fair Scheduler (CFS) running in simulator (LinSched). We have ported the Hackbench scheduler benchmark to this simulator and use this as the workload. The global optimization approach we use is Particle Swarm Optimization (PSO). We make use of Response Surface Methodology (RSM) to specify optimal parameters for our PSO implementation. The one-dimensional local optimization approach we use is the Golden Section method. In order to use this approach, we convert the scheduler tuning problem from one involving setting of three parameters to one involving the manipulation of one parameter. Our results show that the global optimization approach yields better ...
An Otto cycle engine with internal and external irreversibilities of friction and heat leakage, in which the heat transfer between the working fluid and the environment obeys linear phenomenological heat transfer law [q ?? ?(T ?1)], is studied in this paper. The optimal piston motion trajectory for maximizing the work output per cycle is derived for the fixed total cycle time and fuel consumed per cycle. Optimal control theory is applied to determine the optimal piston trajectories for the cases of with and without piston acceleration constraint on each stroke and the optimal distribution of the total cycle time among the strokes. The optimal piston motion with acceleration constraint for each stroke consists of three segments, including initial maximum acceleration and final maximum decel...
Reactive power plays an important role in supporting the real power transfer by maintaining voltage stability and system reliability. It is a critical element for a transmission operator to ensure the reliability of an electric system while minimizing the cost associated with it. The traditional objectives of reactive power dispatch are focused on the technical side of reactive support such as minimization of transmission losses. Reactive power cost compensation to a generator is based on the incurred cost of its reactive power contribution less the cost of its obligation to support the active power delivery. In this paper an efficient Particle Swarm Optimization (PSO) based reactive power optimization approach is presented. The optimal reactive power dispatch problem is a nonlinear optimization problem with several constraints. The objective of the proposed PSO is to minimize the total support cost ...
The detection of explosives is a notoriously difficult problem, especially at stand-off distances, due to their (generally) low vapor pressure, environmental and matrix interferences, and packaging. We are exploring optimal dynamic detection to exploit the best capabilities of recent advances in laser technology and recent discoveries in optimal shaping of laser pulses for control of molecular processes to significantly enhance the standoff detection of explosives. The core of the ODD-Ex technique is the introduction of optimally shaped laser pulses to simultaneously enhance sensitivity of explosives signatures while reducing the influence of noise and the signals from background interferents in the field (increase selectivity). These goals are being addressed by operating in an optimal nonlinear fashion, typically with a single shaped laser pulse inherently containing within it coherently locked ...
An optimal deployment pattern of flux mapping detectors for a Canada uranium-deuterium (CANDU)-600 pressurized heavy water reactor (PHWR) is determined by obtaining an optimal feedback relationship between flux measurements and zone controllers. The reactor core is modeled with a time-dependent two-group, two-dimensional diffusion equation, and flux perturbation are expressed by model expansions. The modal expansion coefficients are used as elements of the state vector representing the system dynamics. An optimal feedback matrix connecting the flux measurement vector to the control vector is derived by minimizing a quadratic performance index involving both the state and control vectors. We obtain the detector effectiveness in terms of the optimal feedback matrix and determine optimal detector locations for the Wolsung Unit 1 reactor in Korea. We have tested the methodology through ...
A total dose hardening treatment is applied to SIMOX buried oxides. Total ionizing dose radiation testing is performed on fully-depleted transistors fabricated on both hardened and non-hardened substrates. At 200 krads x-ray dose, the front gate shift is reduced from -0.7 to -0.2 V for FETs built on the hardened wafers.
The National Radiological Protection Board is to carry out a survey of doses received by patients from the diagnostic use of X-rays, beginning in June 1977, and carried out at over 100 National Health Service hospitals. Details are given of the reasons for carrying out the survey and the survey objectives. The survey working methods are discussed, together with methods of calculation of the genetically significant dose. The radiation doses will be measured by a thermoluminescent dosimeter developed specially for the survey. (U.K.).
Dose-dependent behavior of the infrared stimulated luminescence (IRSL) decay from NaCl has been studied experimentally using only one aliquot irradiated with a range of 2-200 Gy {beta}-radiation doses. It was observed that the maximum IRSL intensity has not changed by an increase in dose though the total intensity increased as expected. Considering the possible implications of our findings for dosimeter, the results were compared with the other studies and discussed.
Electron spin resonance (ESR) dosimetry of irradiated chicken legs is based on the additive dose or the calibration curve methods. In both cases the practical assumption is made that the behaviour of the chicken bone does not depend on factors such as temperature during irradiation, storage conditions and dose rate. So the aim of the present work was to investigate to what extent the above mentioned factors could influence the post-irradiation dose assessment using the ESR technique. (author).
The risks from radiation exposure during radiological diagnosis has usually been estimated in relation to genetic changes. Relevant information has been expressed as the genetically significant dose. In this paper we attempt to produce an analogous measure for evaluating the somatic risk in the form of a somatically significant dose index for radiological and CT examinations. It is shown that, for both types of examination, the two risk factors may be entirely different.
The risks from radiation exposure during radiological diagnosis has usually been estimated in relation to genetic changes. Relevant information has been expressed as the genetically significant dose. In this paper we attempt to produce an analogous measure for evaluating the somatic risk in the form of a somatically significant dose index for radiological and CT examinations. It is shown that, for both types of examination, the two risk factors may be entirely different. (orig.).
Collective dose equivalent and population dose from occupational exposures in Japan, 1988 were estimated on the basis of a nationwide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 0.21 million workers except for the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the official report of the Japan Nuclear Safety Commission. The total number of workers including nuclear power stations was estimated to be about 0.26 million. Radiation works were subdivided as follows: medical works including dental; non-atomic energy industry; research and education; atomic energy industry and nuclear power station. For the determination of effective dose equivalent and population dose, organ or tissue doses were measured with a phantom experiment. ...
Collective dose equivalent and population dose from occupational exposures in Japan, 1988 were estimated on the basis of a nationwide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 0.21 million workers except for the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the official report of the Japan Nuclear Safety Commission. The total number of workers including nuclear power stations was estimated to be about 0.26 million. Radiation works were subdivided as follows: medical works including dental; non-atomic energy industry; research and education; atomic energy industry and nuclear power station. For the determination of effective dose equivalent and population dose, organ or tissue doses were measured with a phantom experiment. ...
Single doses of lead (trace to 445 mg/kg) were administered per os to suckling and adult mice. Both groups exhibited dose-independent lead retention when doses of 4 to 445 mg/kg were administered. However, developmental differences in the fraction of initial dose (FID) retained were evident for all doses administered. A much larger FID was retained in both age groups following administration of carrier-free /sup 203/Pb. The results are consistent with a mechanism of gastrointestinal lead absorption comprising two or more processes. Developmental differences were also observed in organ lead concentration relative to whole body concentration for kidneys, skull and brain 6 days following lead administration. Lead retentions (relative to whole body retention) in brain and in bone were linearly related to dose of lead administered in both suckling and adult age ...
Background: the authors report on the conception and first clinical application of a donut-shaped high-dose configuration for proton therapy (PT). This approach allows one to intensify target volume dose coverage for targets encompassing a critical, dose-limiting structure - like here, the cauda equina -, whilst delivering minimal dose to other healthy structures surrounding the target, thereby reducing the integral dose. Methods and results: intensity-modulated PT methods (IMPT) for spot scanning were applied to create and deliver a donut-shaped high-dose configuration with protons, allowing treating > 75% of the target with at least 95% of the prescribed dose of 72.8 CGE, whilst restricting dose to the cauda equina to 60-65 CGE. Integral dose was lower by a factor of 3.3 as compared to ...
Background: the authors report on the conception and first clinical application of a donut-shaped high-dose configuration for proton therapy (PT). This approach allows one to intensify target volume dose coverage for targets encompassing a critical, dose-limiting structure - like here, the cauda equina -, whilst delivering minimal dose to other healthy structures surrounding the target, thereby reducing the integral dose. Methods and results: intensity-modulated PT methods (IMPT) for spot scanning were applied to create and deliver a donut-shaped high-dose configuration with protons, allowing treating > 75% of the target with at least 95% of the prescribed dose of 72.8 CGE, whilst restricting dose to the cauda equina to 60-65 CGE. Integral dose was lower by a factor of 3.3 as compared to ...
Objective: To investigate the feasibility of low-dose single-slice helical CT in pulmonary CT scan and evaluate the clinical application. Methods: Thirteen cases were selected out of 132 cases, in which low-dose (50mAs) single-slice helical CT scan of chest was performed. This set of cases included 7 cases of multiple metastatic nodules; 3 of solitary pulmonary, nodule; and 3 of pulmonary patchy lesions. Regular dose (170mAs) CT scan was also performed on all those patients. The regular dose and low dose CT scan were compared on sensitivity of detecting the lesions; the performance in demonstrating the details of the abnormalities; and the capability of revealing the segmental bronchi as well. Results: The same number and size of the pulmonary nodules were revealed with scan modalities loaded with different doses. No significant difference in demonstrating the ...
An attempt was made to quantify the radiation risk of diagnostic radiology. After a general introduction of terms as radiation damage, radiation risk and effective dose equivalent, based on publications of the ICRP, somatic dose indexes were computed for several radiologic investigations, that comprise organ doses committed to red bone marrow, lung, female breast and thyroid with and without considering the rest of the body. The dose for the rest of the body was assumed to be equal to the dose received by the red bone marrow, that is also distributed over the whole body. Neglecting the exposure of the rest of the body resulted in an insignificant increase in the estimated somatic risk, with its experimental determination not being necessary. (author).
Full text: An adaptive response is a decreased biological effect induced by a priming radiation dose given prior to a challenge dose. Adaptive responses contradict the linear-nothreshold model of risk estimation. The pKZ1 mouse chromosomal inversion assay is an extremely sensitive assay for studying the mutagenic effect of low dose radiation. A non-linear dose response for chromosomal inversion has been observed in pKZ1 spleen and prostate after a single whole body irradiation with doses between 1?Gy and 10mGy. Doses between 5-10?Gy resulted in an induction in inversions and doses between 1-10mGy resulted in a reduction below endogenous inversion frequency. These results suggest that doses in the 1-10 mGy range cause host responses which overcompensate by not only preventing inversions that would normally occur as a ...
This appendix provides a listing of the BNW-I optimization code, MFCIRI, for a metal finned tube dry-cooled heat rejection system for power plants. (LCL)
The brain maintains internal models of its environment to interpret sensory inputs and prepare actions. While behavioral studies demonstrated that these internal models are optimally adapted...Full Text Available
Optimization of radiation shielding for a medium energy accelerator with 60 MeV alpha ions is carried out using the cost-benefit approach. Cost optimum shield thicknesses are estimated for different operating conditions of the accelerator. (author). 5 refs, 1 tab.
Background and objectives: Patients receiving dialysis have a high burden of cardiovascular disease. Some receive coronary artery revascularization but the optimal method is controversial.Design,...Full Text Available
The highly variable and intermittent pollutant concentrations and flowrates associated with wet-weather events in combined sewersheds necessitates the use of storage-treatment systems to control pollution.An optimized combined-sewer-overflow (CSO) control system requires a manage...
Operation of an X-ray spectrometer based on a spherical variable-line-spacing (VLS) grating is analyzed using dedicated ray-tracing software allowing fast optimization of the grating parameters and...Full Text Available
Cancer treatment with ionizing radiation is often compromised by organ motion, in particular for lung cases. Motion uncertainties can significantly degrade an otherwise optimized treatment plan....Full Text Available
A dissipative particle swarm optimization is developed according to the self-organization of dissipative structure. The negative entropy is introduced to construct an opening dissipative system that is far-from-equilibrium so as to driving the irreversible evolution process with better fitness. The testing of two multimodal functions indicates it improves the performance effectively
Purposes1. To determine the optimal pelvic nodal clinical target volume for post-operative treatment of endometrial cancer. 2. To compare the DVH of different treatment planning...Full Text Available
The problem of optimizing a horn radiator of electromagnetic waves for the reflection coefficient and the coefficient of transformation of the fundamental mode into higher order modes is solved. Optimization is performed by means of selecting a combined shape of the radiator generatrices.
The High Flux Isotope Reactor (HFIR) located at Oak Ridge National Laboratory is one of the world's most powerful research reactors. In 1996, one year after the demise of the Advanced Neutron Source Project, the U.S. Department of Energy embarked on an aggressive program to upgrade the neutron scattering facilities at the HFIR. These upgrades, which are now in progress, include the installation of larger beam tubes, a high-performance hydrogen cold source, and additional neutron guides and neutron scattering instruments. An extensive analysis effort was performed over the past 4 yr to support the design of the modified beamlines and new user facilities and to assess the impact of the upgrades on the integrity of the existing reactor system. The results of three of these analyses are summarized here. Specifically, results are presented for analyses related to the design of the new cold neutron source (CNS), the assessment of beam tube changes on the anticipated pressure vessel lifetime, ...
This study describes the formulations to optimize the time interval of inspections and/or replacements of equipment/parts taking into account the probability density functions (PDF) for failure rates and parameters of failure distribution functions (FDF) and evaluates the optimized results of these time intervals using our formulations by comparing with those using only representative values of failure rates and the parameters of FDF instead of using these PDFs. The PDFs are obtained with Bayesian method and the representative values are obtained with likelihood estimation method. However, any significant difference is not observed between both optimized results within our preliminary calculations. (author)
This paper presents a new algorithm for the optimal long-range generation planning for a thermal system with pumped-storage plants. The algorithm is based upon the analytical production costing model developed under the assumption of Gaussian probabilistic distribution of random load fluctuations and plant outages. The optimization problem consists of the master problem to determine the annual investment, and the pumped-storage subproblem to determine the optimal pumped-storage operation. The master problem is formulated as a Hamiltonian minimization problem, and the pumped-storage subproblem is solved using the concept of peak-shaving operation on the original load curve.
This paper presents a new algorithm for the optimal long-range generation planning for a thermal system with pumped-storage plants. The algorithm is based upon the analytical production costing model developed under the assumption of Gaussian probabilistic distribution of random load fluctuations and plant outages. The optimization problem consists of the master problem to determine the annual investment, and the pumped-storage subproblem to determine the optimal pumped-storage operation. The master problem is formulated as a Hamiltonian minimization problem, and the pumped-storage subproblem is solved using the concept of peak-shaving operation on the original load curve.
Particle Swarm Optimization technique offers optimal or suboptimal solution to multidimensional rough objective functions. In this paper, this optimization technique is used for designing fractional order PID controllers that give better performance than their integer order counterparts. Controller synthesis is based on required peak overshoot and rise time specifications. The characteristic equation is minimized to obtain an optimum set of controller parameters. Results show that this design method can effectively tune the parameters of the fractional order controller.
A method for automatic optimal feeder design in steel casting processes is presented. The initial design is the casting part (without feeders) which is placed in a suitable mold box. Design of each feeder contains the following steps: determination of the feeder-neck connection point on the casting surface, initial feeder design, feeder shape optimization and feeder topology optimization. Completing designing the first feeder, the method attends to designing the next one, if it is required, and the same procedure will be repeated. In the presented method, feeders are designed in a descending order of their sizes. The feasibility of the presented method is supported with an illustrative example.
The results for development of methods and computer programs for integrated optimization of parameters of perspective fast reactors are given. The possibilities of the program for the reactor campaign calculation are analysed. This program is based on utilisation of the Bubnov-Galerkin method and Wigner disturbance theory. The possibility of application of approximation methods for the optimization researches is discussed. The results of development of the programs for complex reactor computations with account of control rods system and change of physical parameters in the reactor campaign are discussed. (author).
This paper suggests how nonlinear periodic optimal control of a pumped storage plant can be realized. The control problem consists in maximization of the plant benefits over an operational period. An optimal control law is proposed, yielding a bang-off-bang mode of operation. An algorithm for numerical solution of the problem was developed, and its effectiveness was demonstrated by simulation experiments.
In the present paper the progress of optimization of soft magnetic properties have been studied by applying different experimental techniques (magnetic measurements, electric measurements, X-ray analysis, and high-resolution electron microscopy observation). It has been shown that an increase in magnetic permeability after optimization annealing can be mainly attributed to annealing out of microvoids. (author)
An optimization criterion accounting for the energy and material consumption is defined. The allowed limits of the variations in the technological factors are discussed and the optimization criterion values within these limits are calculated. The analysis presented, demonstrating the significance of the chosen factors for the production cost-price, is of great practical importance. (orig.).
This paper discusses, partially, the advantages and the disadvantages of the optimal power flow. It shows some of the difficulties of implementation and proposes solutions. An analysis is made comparing the power flow, BIGPOWER/CESP, and the optimal power flow, FPO/SEL, developed by the author, when applied to the CEPEL-ELETRONORTE and CESP systems. (author) 8 refs., 5 tabs.
In this paper, a new design methodology for determining the size, location, type and number of capacitors to be placed on a radial distribution system is presented. The objective is to minimize the peak power losses and the energy losses in the distribution system considering the capacitor cost. A sensitivity analysis based method is used to select the candidate locations for the capacitors. A new optimization method using a Genetic Algorithm is proposed to determine the optimal selection of capacitors. Test results have been presented along with the discussion of the algorithm.
One of the main goals in the operation of a cupola furnace is to keep the molten iron properties within prescribed bounds while maintaining the most economical operation for the cupola. In this paper the authors present a procedure to obtain the nominal values for the manipulated process variables. The nominal values are calculated by solving a constrained nonlinear programming optimization problem. Two different optimization problems are discussed and examples for using the procedure are presented.
We obtain a simple derivation of the optimal quantum state estimation of a two-level system using the no-signaling principle. In particular, we show that the no-signaling principle determines the unique form of the guessing probability, independently to a given figure of merit such as the fidelity or the information gain. This proves that optimal measurements for a two-level quantum system is the same for almost all figures of merit.
The authors present a new concept: 'adaptive optimal reclosure' under transmission line faults by integrating the adaptive and optimal reclosure techniques. Simulation studies prove that the proposed technique is able to first detect the persistence time of fault path arc and then capture the optimal reclosure time, thereby enhancing system stability. (author)
Implementation of an adaptive power system stabilizer (PSS) based on linear optimal control is described in this paper. The generator is identified in real time, and a special 3rd order discrete Riccati equation is solved in each sample interval. Because the output of the generator is fed back directly, the controller can track the system very fast. Experimental studies on a physical model of a power system demonstrate the effectiveness of the proposed adaptive optimal controller.
Nature-inspired algorithms such as Particle Swarm Optimization and Firefly Algorithm are among the most powerful algorithms for optimization. In this paper, we intend to formulate a new metaheuristic algorithm by combining Levy flights with the search strategy via the Firefly Algorithm. Numerical studies and results suggest that the proposed Levy-flight firefly algorithm is superior to existing metaheuristic algorithms. Finally implications for further research and wider applications will be discussed.
The optimization of ethylene furnace operations using cfd-based simulations has been addressed. The optimization problems have been cast into various formulations: the Multidisciplinary feasible (MDF) approach, the All-At-Once (AAO) approach and the Individual discipline feasible (IDF) approach. These approaches mainly differ in their handling of the state equations as constraints, and hence some of the formulations place restrictions on the methods used to solve the state equations.
In 1978 the Marshall Islands Radiological Safety Program was organized to perform radiation measurements and assess radiation doses for the people of the Bikini, Enewetak, Rongelap and Utirik Atolls. One of the major field components of this program is whole- body counting (WBC). WBC is used to monitor the quantity of gamma- emitting radionuclides present in individuals. A primary objective of the program was to establish {sup 137}Cesium body contents among the Enewetak, Rongelap and Utirik populations. {sup 137}Cs was the only gamma-emitting fission radionuclide detected in the 1,967 persons monitored. {sup 137}Cs body burdens tended to increase with age for both sexes, and were higher in males. The average {sup 137}Cs dose Annual Effective Dose for the three populations was as follows: For Enewetak, the dose was 22{+-}4 {mu}Sv. For Utirik, the dose was 33{+-} 3 {mu}Sv. Since 1985 ...
The medical applications of radiation comprise three main fields namely: Diagnostic Radiology, Radiotherapy and Nuclear Medicine. With the new weighting factors of ICRP (IC91a) the effective dose due to medical applications can be established. I is common to separate the effective dose into the genetic part and the somatic part, SED. In dealing with gonad doses it is important to account for the age of the person at the time of exposure as this will influence the number of children still to be expected from that person. The resulting dose will then be called the genetically significant dose, GSD. In a similar fashion this age factor will be important in considering the chance of tumor induction. The age of patients differs considerably from the average age of the general population. This age difference has to be accounted for if a comparison is to be made with other sources of ...
Safety assessments for clearance of H-beam and valves, main radioactive metal wastes in Kori nuclear power plants, were carried out to derivate a decontamination factor for satisfying the dose limits of clearance level (Maximum individual dose: 10 {mu}Sv/y, collective dose: 1 man{center_dot}Sv/y) in Korea. Maximum individual dose and collective dose were evaluated by internal dose conversion factor which based on the concept of effective dose in ICRP publication 60. The results of maximum individual dose and collective dose is 139 {mu}Sv per year and 0.166 man{center_dot}Sv per year about H-beam, and 158 {mu}Sv per year and 0.468 man{center_dot}Sv per year about valves respectively. Demand decontamination factor satisfied with, which is respectively more than 13.9 and 15.8 for satisfying clearance ...
Safety assessments for clearance of H-beam and valves, main radioactive metal wastes in Kori nuclear power plants, were carried out to derivate a decontamination factor for satisfying the dose limits of clearance level (Maximum individual dose: 10 #mu#Sv/y, collective dose: 1 man#centre dot#Sv/y) in Korea. Maximum individual dose and collective dose were evaluated by internal dose conversion factor which based on the concept of effective dose in ICRP publication 60. The results of maximum individual dose and collective dose is 139 #mu#Sv per year and 0.166 man#centre dot#Sv per year about H-beam, and 158 #mu#Sv per year and 0.468 man#centre dot#Sv per year about valves respectively. Demand decontamination factor satisfied with, which is respectively more than 13.9 and 15.8 for satisfying clearance ...
The determination of the dose to organs from diagnostic x rays has become important because of reports of radiation injury to patients from fluoroscopically guided interventional procedures. We have modified a convolution/superposition-based treatment planning system to compute the dose distribution for kilovoltage beams. We computed lung doses using this system and compared them to those calculated using the CDI3 organ dose calculation program. We also computed average lung doses from a simulated radiofrequency ablation procedure and compared our results to published doses for a similar procedure. Doses calculated using this system were an average of 20% lower for AP beams and 7% higher for PA beams than those obtained using CDI3. The ratio of the average dose to the lungs to the skin dose from the ...
Accelerated aging tests on tin-oxide-coated anodized aluminium selective absorber surfaces have been performed. It is shown that the tin oxide layer provides excellent protection for the anodized surface. The thermal stability of the double layer is equal to, or better than, the stability of the bare anodized surface. Both surfaces degrade very slowly at 450deg C. The anodic layer is porous and therefore not very scratch resistant and it degrades when exposed to humidity, both acidic and alcaline. It is shown that the tin oxide film, which is hard and chemically very stable, almost completely protects the anodized surface from chemical degradation. The mechanical wear resistance is also considerably improved. The optical selectivity does not quite match that of the the anodized surface, but the remarkable stability together with the solar parameters of {alpha}=0.91 and hemispherical emittance {epsilon}= 0.16 (normal emittance {epsilon}{sub n}=0.12) make this ...
Lyman-limit absorption systems can play many important roles during and after cosmological reionization. Unfortunately, due to the prohibitively large dynamic range required, it is impossible to self-consistently include these systems in cosmological simulations. Using fast and versatile semi-numeric simulations, we systematically explore the spatial distribution of absorption systems during and following reionization. We self-calibrate the resulting number of absorbers to the mean free path (mfp) of the ionizing ultraviolet background (UVB), and present results at a given mfp and neutral hydrogen fraction. We use a simple optical depth criterion to identify the locations of absorbers. Our approach is fairly robust to uncertainties such as missing subgrid structure. Unlike at lower redshifts where the UVB is relatively uniform, at higher redshifts the fluctuations in the UVB and the HII morphology of reionization can drive the large-scale ...
A possible receiver configuration is a cavity in which a falling sheet of solid particles is directly irradiated by the concentrated solar flux passing through the aperture. Regardless of the particular geometry, the radiative transfer within the falling particle curtain must be studied in order to determine the net radiative heating rate for the particles. A discrete ordinate radiative transfer model has been developed to predict the radiative coupling within the falling particle curtain. The model determines how much energy is absorbed by the particles, how much is transmitted to the rear wall of the receiver, and determines the effects of particle scattering and thermal emission on the net radiation absorbed by the particles. The model accounts for the directional nature of the radiation field, particle scattering, and the wavelength dependence of the optical properties. The discrete ordinate model has been used to assess the influence of ...
Two methods to cool muon beams deeply below the limit conventionally established for the ionization cooling are proposed. In Phase Ionization Cooling (PIC), the beam is focused at wedge absorber plates each half of particle oscillation period by imposing a weak parametric resonance along the beam path. The resonance growth of particle amplitude is surmounted by the ionization cooling. At optimum, such arrangement results in reduction of each of two transverse emittances by an order of value in addition to the preceding 6D ionization cooling. Next, resonance focusing and transverse cooling can be continued in the regime of a fast Reverse Emittance Exchange (REMEX). Here, the sign of the absorber wedge is opposite to PIC while the dispersion increased. REMEX to be accompanied by the bunch lengthening and acceleration in order to maintain the relative energy spread at an appropriate level. The limitations due to energy straggling in ...
Peeled Avena sativa coleoptile sections have been used to study the control of solute uptake under conditions where the uptake is not limited by the cuticular barrier. In the presence of 2% sucrose, auxin enhances the rate at which the total osmotic solutes increase, but this appears to be a response to the increased growth rate, inasmuch as the auxin effect is eliminated when growth is inhibited osmotically. When sections are incubated in sucrose or in 10 millimolar NaCl, the osmotic concentration increases until a plateau is reached after 8 to 24 hours. Auxin has no effect on the initial rate of increase in osmotic concentration. This difference in steady-state osmotic concentration is, in part, a response to auxin itself, as it persists when auxin-induced growth is inhibited osmotically. The upper limit for osmotic concentration does not appear to be determined by the turgor pressure, inasmuch as a combination of sucrose and NaCl gave a higher plateau osmotic concentration than did ...
The AFGD process as demonstrated by Pure Air at the Bailly Station offers a reliable and cost-effective means of achieving a high degree of SO{sub 2} emissions reduction when burning high-sulfur coals. Many innovative features have been successfully incorporated in this process, and it is ready for widespread commercial use. The system uses a single-loop cocurrent scrubbing process with in-situ oxidation to produce wallboard-grade gypsum instead of wet sludge. A novel wastewater evaporation system minimizes effluents. The advanced scrubbing process uses a common absorber to serve multiple boilers, thereby saving on capital through economies of scale. Major results of the project are: (1) SO{sub 2} removal of over 94 percent was achieved over the three-year demonstration period, with a system availability exceeding 99.5 percent; (2) a large, single absorber handled the combined flue gas of boilers generating 528 MWe of power, and no spares were ...
Basic experimental investigations were carried out with an aqueous solution of a mixture of KOH and NaOH for use as an absorbent in absorption heat pumps. Due to its thermophysical properties this mixture allows temperature lifts from evaporator to absorber of more than 75 K (135 F) in a single-stage absorption chiller. Thermophysical and hydrodynamical properties of the solution were measured. Vapor-liquid-equilibrium data and specific heat capacities were determined for concentrations ranging from 35% up to 75% and temperatures up to 200 C (392 F). From these data the enthalpy of the solution was calculated. Additionally the crystallization temperatures, the density, and the viscosity of the solution were determined. The experimental equipment is described. The data are presented as polynomials and diagrams including experimental accuracy. An apparatus was constructed to measure heat and mass transfer coefficients of the absorption process ...
For the step-and-shoot intensity-modulated radiation therapy (IMRT) technique, the combination of high dose rate, multiple beam segments and low dose per segment can lead to significant differences between the planned dose and the dose delivered to the patient. In this technique, a dose delivery inaccuracy known as the 'overshoot' effect is caused by the dose servo control system. This typically occurs in the first and last beam segments and causes an over- and underdose, respectively. Some dose positional error in the segment sequence is also possible there. Commercial ionization chambers (RK-type) and radiographic Kodak films were used for the measurements. The reported results were obtained using the Pinnacle{sup 3}-V6.2 treatment planning system and a Varian Clinac 21 EX linear accelerator equipped with a 120-leaf ...
The Proportional-Integral-Derivative Controller is widely used in industries for process control applications. Fractional-order PID controllers are known to outperform their integer-order counterparts. In this paper, we propose a new technique of fractional-order PID controller synthesis based on peak overshoot and rise-time specifications. Our approach is to construct an objective function, the optimization of which yields a possible solution to the design problem. This objective function is optimized using two popular bio-inspired stochastic search algorithms, namely Particle Swarm Optimization and Differential Evolution. With the help of a suitable example, the superiority of the designed fractional-order PID controller to an integer-order PID controller is affirmed and a comparative study of the efficacy of the two above algorithms in solving the optimization problem is also presented.
Using a Markov Chain Monte Carlo optimization algorithm and a computer simulation, I find the passenger ordering which minimizes the time required to board the passengers onto an airplane. The model that I employ assumes that the time that a passenger requires to load his or her luggage is the dominant contribution to the time needed to completely fill the aircraft. The optimal boarding strategy may reduce the time required to board and airplane by over a factor of four and possibly more depending upon the dimensions of the aircraft. I explore some features of the optimal boarding method and discuss practical modifications to the optimal. Finally, I mention some of the benefits that could come from implementing an improved passenger boarding scheme.
This article describes a methodology that implements a Markov decision process (MDP) optimization technique in a real time fed-batch experiment. Biological systems can be better modeled under the stochastic framework and MDP is shown to be a suitable technique for their optimization. A nonlinear input/output model is used to calculate the probability transitions. All elements of the MDP are identified according to physical parameters. Finally, this study compares the results obtained when optimizing ethanol production using the infinite horizon problem, with total expected discount policy, to previous experimental results aimed at optimizing ethanol production using a recombinant Escherichia coli fed-batch cultivation. (c) 1997 John Wiley & Sons, Inc. Biotechnol Bioeng 55: 317-327, 1997. PMID:18636490
Incomplete convergence in numerical simulation such as computational physics simulations and/or Monte Carlo simulations can enter into the calculation of the objective function in an optimization problem, producing noise, bias, and topo- graphical inaccuracy in the objective function. These affect accuracy and convergence rate in the optimization problem. This paper is concerned with global searching of a diverse parameter space, graduating to accelerated local convergence to a (hopefully) global optimum, in a framework that acknowledges convergence uncertainty and manages model resolu- tion to efficiently reduce uncertainty in the final optimum. In its own right, the global-to-local optimization engine employed here (devised for noise tolerance) performs better than other classical and contemporary optimization approaches tried individually and in combination on the "industrial" test problem to be ...
Feature selection refers to the problem of selecting relevant features which produce the most predictive outcome. In particular, feature selection task is involved in datasets containing huge number of features. Rough set theory has been one of the most successful methods used for feature selection. However, this method is still not able to find optimal subsets. This paper proposes a new feature selection method based on Rough set theory hybrid with Bee Colony Optimization (BCO) in an attempt to combat this. This proposed work is applied in the medical domain to find the minimal reducts and experimentally compared with the Quick Reduct, Entropy Based Reduct, and other hybrid Rough Set methods such as Genetic Algorithm (GA), Ant Colony Optimization (ACO) and Particle Swarm Optimization (PSO).
Objective: To develop software for assessment of dose to thyroid gland in emergencies resulting in the release of radioiodine. Methods: Based on procedures for thyroid monitoring and dose assessment introduced in IAEA publications (IAEA-TECDOC-1092 and EPR-MEDICAL-2005), a software was developed with Visual Basic 6.0 program to computerized the methods of thyroid dose estimation. Results: The intake of radioiodine and committed equivalent dose to thyroid could be estimated rapidly and accurately with the present software. Conclusion: The present software provide a practical and rapid tool for estimating thyroid doses received in emergencies resulting in the release of radioiodine by emergency workers and members of public, which is necessary for recommendation of further actions. (authors)
The basic relationships of the convolution/superposition dose calculation technique are reviewed, and a modelling technique that can be used for obtaining a satisfactory beam model for a commercially available convolution/superposition-based treatment planning system is described. A fluence energy spectrum for a Co-60 treatment machine obtained from a Monte Carlo simulation was used for modelling the fluence spectrum for a Rokus M machine. In order to achieve this model we measured the depth dose distribution and the dose profiles with a Wellhofer dosimetry system. The primary fluence was iteratively modelled by comparing the computed depth dose curves and beam profiles with the depth dose curves and crossbeam profiles measured in a water phantom. The objective of beam modelling is to build a model of the primary fluence that the patient is exposed to, which can then be used for the ...
When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).
When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).
Lifetime of minority charae carriers in the Si and Ge p-n unctions has been measured by pulse method of conductivity modulation of base. Its dependence on the X-ray radiation dose has been investigated. Dependence of current transmission coefficients on the dose has been measured and their sharp decrease at low doses and the following saturation at high doses have been observed. Linear dependence of lifetime on X-ray radiation dose has been obtained. Resulting from the comparison of regularities of the change of lifetime due to current characteristics, it has been shown that X-ray radiation leads to the formation of the surface defects, influencing the change of current characteristics as well as to stationary structural defects, causing the decrease of lifetime of the charge carriers with the increase of X-ray radiation dose.
The ECOSYS model is used to estimate ingestion dose in the ARGOS and RODOS decision support systems for nuclear emergency management. It is recommended that nation-specific values for several parameters are used in the model. However, this is generally overlooked when the systems are used in practice. We have estimated first year ingestion doses in two scenarios with wet and dry deposition of 137Cs, using the ECOSYS model. We calculated doses for each country using national dietary data while keeping all other parameters at their default values. These dose calculations were then used to estimate the variation in ingestion doses resulting from the variation in the diets only. The dietary data demonstrated that the average consumption of milk, meat and vegetables varied by a factor of 2-4 am...
This study investigated dose to bone tissue in electron beam therapy. Measurements were made using films and thermoluminescent dosimeters in a polystyrene phantom containing bone inhomogeneity for 15-MeV, 12-MeV, and 9-MeV electron beams. An increase in dose of approximately 18%, 12%, and 11%, for the three electron energies respectively, relative to the dose in polystyrene, was found for bone material having an electron density (relative to water) of 1.73. Measurements were also made using films for 15- and 9-Mev electrons in a phantom with a mandibular bone and teeth. A dose enhancement in bone of approximately 10% and 7%, respectively, for the two energies was found in the phantom where the electron density of bone was about 1.60. These results suggest that injury to bone is possible in those clinical situations where high doses of electrons are used for therapy.
This study investigated dose to bone tissue in electron beam therapy. Measurements were made using films and thermoluminescent dosimeters in a polystyrene phantom containing bone inhomogeneity for 15-MeV, 12-MeV, and 9-MeV electron beams. An increase in dose of approximately 18%, 12%, and 11%, for the three electron energies respectively, relative to the dose in polystyrene, was found for bone material having an electron density (relative to water) of 1.73. Measurements were also made using films for 15- and 9-Mev electrons in a phantom with a mandibular bone and teeth. A dose enhancement in bone of approximately 10% and 7%, respectively, for the two energies was found in the phantom where the electron density of bone was about 1.60. These results suggest that injury to bone is possible in those clinical situations where high doses of electrons are used for therapy.
The Monte Carlo method is used to analyse the dose fall-off at the exit surface of a megavoltage photon beam. The convolution/superposition method of dose calculation using Monte-Carlo-generated homogeneous photon kernels is shown to be in error for exit dose calculation. Instead, photon kernels that incorporate modelling of the exit surface were generated, also using Monte Carlo, to analyse the problem, and the calculated dose fall-off using these kernels agrees well with measured data. In addition, the physics underlying the characteristics of the dose fall-off is analysed based on complete Monte Carlo modelling. Practical improvements to the convolution/superposition method are suggested. (Author).
The detection of foot-and-mouth disease (FMD) virus from various kinds of field samples (tissue extract and cell culture isolate) was studied using the polymerase chain reaction (PCR) technique. The gene selected for diagnosis was the polymerase gene and an amplification target product of 454 bp in length was produced using AP5/AP6 primer sets. The PCR product was further examined by NcoI endonuclease digestion. The presence of the internal restriction site was confirmed by demonstration of two small fragments of 330 bp and 124 bp in length. Forty-nine samples that gave positive and negative results by ELISA typing and were positive by the PCR test were tested by NcoI digestion to confirm the results. About 10% of PCR products could not be confirmed by the method. Furthermore the FMD RNA polymerase gene could be detected by the PCR method in samples negative in both ELISA typing and the virus isolation test. A total of 23 samples were examined and compared after each stage of the ...
Polymeric coated ferromagnetic carriers with an absorbed layer of octyl(phenyl)-N,N-diisobutylcarbamoylmethylphosphine oxide (CMPO) diluted by tributyl phosphate (TBP) are being evaluated for application in the separation and the recovery of low concentrations of americium, plutonium, and uranium from nuclear waste solutions. Due to their chemical nature, these extractants selectively complex americium and plutonium contaminants onto the particles and the complexed particles can be recovered from the solution using a magnet. Physical and chemical characterization of the extractant-absorbed particles were performed by gamma and liquid scintillation counting, scanning electron microscopic (SEM) micrograph, and other physical measurements. Plutonium, americium, and uranium separations have been performed at various HNO{sub 3} and HCl concentrations. Parameters were studied to determine the limitations and capacity of the process. The status of the ...
A solar energy desalination process utilizing solar radiation directly for the evaporation of salt water is described. Ambient air takes on water vapor as the air passes through an evaporative medium. It is then directed between a saline water-covered, solar absorbing surface and a solar collecting housing. The resulting heated and moisture-saturated air is cooled in a heat exchange means where condensation of fresh water occurs. Simultaneously, cool salt water is utilized as the cooling water in the heat exchange means, and takes on the heat of condensation given up by the condensing vapor. The heated salt water from the heat exchange means is partially directed over the solar absorbing surface, and at least a portion of it is also directed to wet the evaporative medium. Several optional sub-processes are described for operation of the system during periods of reduced insolation, and an alternative process is described for operation of the ...
Labelling of "1"4C-M-ISP and its absorption, translocation and distribution in peanut and soybean seedling were studied. The results of experiments showed that the radioactive substance could be translocated in xylem and phloem of two kinds of plants. The root of peanut seedling absorbed "1"4C-M-ISP from the nutrient solution more strong than the root of soybean seedling did. After leaf treatment with "1"4C-M-ISP, the soybean seedling absorbed more radioactive substance than peanut seedling did. But the translocation's speed of radioactive substance in pnloem of two kinds of plants were similar.
A glass heat pipe is adapted for use as a solar energy absorber in an evacuated tube solar collector and for transferring the absorbed solar energy to a working fluid medium or heat sink for storage or practical use. A capillary wick is formed of granular glass particles fused together by heat on the inside surface of the heat pipe with a water glass binder solution to enhance capillary drive distribution of the thermal transfer fluid in the heat pipe throughout the entire inside surface of the evaporator portion of the heat pipe. Selective coatings are used on the heat pipe surface to maximize solar absorption and minimize energy radiation, and the glass wick can alternatively be fabricated with granular particles of black glass or obsidian.
The Monte-Carlo transport code MCNP was used to evaluate possible arrangements of cores for the MIT Reactor using monolithic LEU fuel. Plate and moderator thicknesses were varied, and fixed absorbers and inner reflectors added in an effort to maximize available neutron fluxes at in-core and ex-core locations of experimental facilities. Addition of D_2O in the H_2O moderator was also evaluated. Comparisons of the fast, epithermal, and thermal fluxes were made at selected locations. Keff was also evaluated and critical blade heights compared with the existing HEU core. Results indicate that the LEU fluxes could approach HEU values with the use of a fueled in-core experimental facility, a fixed boron absorber spider and an inner beryllium reflector. (author)
In this work, a comprehensive model has been developed for the absorption of carbon dioxide into promoted hot potassium carbonate solution. The model, which is based on penetration theory, incorporates an extensive set of important reactions and takes into account the coupling between mass transfer and chemical kinetics. The penetration theory provides an appropriate absorption rate and enhancement factor for the chemical absorption. Operating data for carbon dioxide absorption into DEA-hot potassium carbonate solution has been compared with model predictions. The impact of parameters such inlet temperature of lean solution, promoter concentration, liquid split fraction, hot feed location and type of promoter on the performance of a split-flow absorber have been examined. The use of other promoters is an efficient way to enhance the carbon dioxide absorption, which has been discussed in this paper.
The interaction of thermal radiation with conduction and convection in thermally developing absorbing, emitting, nongray gas-particulate turbulent suspension flow through a circular tube is investigated. The contribution of thermal radiation is obtained through evaluation of the total hemispherical emittance of the particulate cloud and through evaluation of single band absorptances for molecular gases, modified to account for the interaction with the particles. The governing differential equation is derived as a (nonlinear) energy equation, coupled with integral equations to find the thermal radiation contributions. The energy equation is solved numerically by an implicit finite difference method with an iterative procedure. Qualitative results for Nusselt numbers are shown for a variety and range of parameters, such as optical thickness of particulates and single molecular gas bands, relative gas band position and band width, and temperature ratios (heated as ...
The interaction of thermal radiation with conduction and convection in thermally developing absorbing, emitting, non-gray gas particulate turbulent suspension flow through a circular tube is investigated. The contribution of thermal radiation is obtained through evaluation of the total hemispherical emittance of the particulate cloud and through evaluation of single band absorptances for molecular gases, modified to account for the interaction with the particles. The governing differential equation is derived as a (nonlinear) energy equation, coupled with integral equations to find the thermal radiation contributions. The energy equation is solved numerically by an implicit finite difference with its iterative procedure. Qualitative results for Nusselt numbers are shown for a variety and range of parameters, such as optical thickness of particulates and single molecular gas bands, relative gas band position and band width, and temperature ratios (heated as well as ...
The absorption of carbonyl sulfide in aqueous methyldiethanolamine (MDEA) was studied over a range of temperatures and MDEA concentrations. MDEA is commonly used for selective absorption of hydrogen sulfide in the presence of carbon dioxide. However, sulfur in the form of COS may also be present and it is necessary that estimates of absorption rates of this compound be made. The objective of this study is to determine the physiochemical properties needed to predict COS absorption rates in aqueous MDEA. Free gas solubility and the diffusivity of COS in MDEA solutions were measured over the temperature range 15 to 40{sup 0}C for MDEA concentrations up to 30 weight per cent using the nitrous oxide analogy method. Solubilities were measured volumetrically in an equilibrium cell and diffusivities were measured using a laminar liquid jet absorber. The kinetics of the reaction between COS and MDEA were studied by measuring absorption rates in a single wetted-sphere ...
For intensity modulated radiation treatment (IMRT) dose reconstruction, multileaf collimator (MLC) log files have been shown applicable for deriving delivered fluence maps. However, MLC log files are...Full Text Available
1. The antihypertensive efficacy and tolerability of a low dose combination of the angiotensin converting enzyme inhibitor ramipril (2.5 mg) and the extended release formulation of the dihydropyridine...Full Text Available
We developed a new TLD array for precise dose measurement and verification of the spatial dose distribution in small radiation targets. It consists of a hemicylindrical, tissue-equivalent rod made of polystyrene with 17 parallel moulds for an exact positioning of each TLD. The spatial resolution of the TLD array was evaluated using the Leskell spherical phantom. Dose planning was performed with KULA 4.4 under stereotactic conditions on axial CT images. In the Leksell gamma unit the TLD array was irradiated with a maximal dose of 10 Gy with an unplugged 14 mm collimator. The doses delivered to the TLDs were rechecked by diode detector and film dosimetry and compared to the computer-generated dose profile. We found excellent agreement of our measured values, even at the critical penumbra decline. For the 14 mm and 18 mm collimator and for the 11 mm collimator ...
Estimations on the somatic and genetic effects of small doses of ionizing radiations in Man have been proposed by the Advisory Committee on the Biological Effects of Ionizing Radiation, set up by the U.S. National Academy of Sciences. They have been published in an important report, issued in 1972, from which we briefly analyze here the Chapter dealing with the somatic effects. Small doses of raditions are expected to promote only carcinogenic effects. After a rapid survey of the human experience on which the estimations are based, as regards the latent period of cancers, the plateau region (period of high risk) and the absolute and relative risk expressed per rem, per 10"6 persons, per year, for leukaemia (having the highest risk) and for the ''other cancers''. These estimations were obtained by linear extrapolation to the 1 rem level from observations made after irradiation at relatively high dose levels and much higher ...
The pharmacokinetics of ceftriaxone were investigated in six healthy mainland Chinese adults (four males and two females). A single 1.0-g dose was administered intravenously or intramuscularly in a...Full Text Available
Objectives To provide direct estimates of risk of cancer after protracted low doses of ionising radiation and to strengthen the scientific basis of radiation protection standards for environmental,...Full Text Available
AimsTo assess the tolerability and pharmacokinetic profile of single and repeat doses of the oral matrix metalloproteinase inhibitor marimastat in healthy male volunteers.Full Text Available
Calculations of dose per monitor unit (D∕MU) are required in addition to measurements to increase patient safety in the clinical practice of proton radiotherapy. As in conventional photon and...Full Text Available
The achievements made in the field of radiation protection over the past 20 years are outlined. Risk analysis as applied to medicine is considered and genetic significant doses, genetic risks, somatic effective doses and somatic risks are discussed. (C.F.).
Low dose methotrexate has been used effectively for various rheumatic and non-rheumatic diseases. Three cases of Pneumocystis carinii pneumonia occurring during treatment of rheumatoid arthritis with...Full Text Available
The reference medium for brachytherapy dose measurements is water. Accuracy of dose measurements of brachytherapy sources is critically dependent on precise measurement of the source–detector...Full Text Available
AbstractMilk residues and performance were evaluated in lactating cows that were fed up to 10 times the recommended dose of monensin. Following an acclimatization period of 14 d, during...Full Text Available
The purpose of this report is to summarize the assumptions, dose factors, consumption rates, and methodology used to evaluate potential radiation doses to persons who may eat contaminated wildlife or contaminated plants collected from the Hanford Site. This report includes a description of the number and variety of wildlife and edible plants on the Hanford Site, methods for estimation of the quantities of these items consumed and conversion of intake of radionuclides to radiation doses, and example calculations of radiation doses from consumption of plants and wildlife. Edible plants on the publicly accessible margins of the shoreline of the Hanford Site and Wildlife that move offsite are potential sources of contaminated food for the general public. Calculations of potential radiation doses from consumption of agricultural plants and farm animal products are made routinely and ...
For the risk estimate of fatal malignancies, an effective dose was proposed on the basis of the assumption that the risk should be equal whether the whole body irradiated uniformly or whether there is non-uniform irradiation. The effective dose was defined by the product of organ or tissue doses and a weighting factor representing the proportion of risk factor for a fatal malignancy resulting from organ or tissue irradiation to the total malignant factor. The risk of malignancies can be derived by multiplying the malignant significant factor by the product of the risk factor and the effective dose. For the genetic risk, a significant factor was a relative child expectancy and organ or tissue doses were gonad doses. And, for the leukemogenic risk, a significant factor was the leukemia significant factor and organ or tissue dose was mean bone ...
1. The LD50 of iodomethane orally administered to rats is 76mg./kg. body wt. but repeated daily doses of 30–50mg./kg. body wt. are without effect. 2. Oral doses of iodomethane to...Full Text Available
Objective:In this article, we describe a successful low-dose, off-label usage of drotrecogin alfa (Xigris), given at 18 mcg/kg per hour, in a patient with severe sepsis who had an...Full Text Available
ObjectiveTo assess the efficacy and safety of low dose adrenaline injected subcutaneously to prevent acute adverse reactions to polyspecific antivenom serum in patients admitted...Full Text Available
Rats were exposed to aerosols of "2"3"3U and "2"3"2U nitrate in a study of the long-term biological effects. Preliminary radiation dose estimates show lung > skeleton > kidney in each dose group.
The equivalent doses of K-feldspar grains in a range of grain sizes from 90 to 250#mu#m diameter were measured using a single-aliquot regenerative-dose protocol for the infrared stimulated luminescence (IRSL) signals for two samples of desert sand. The equivalent doses for each sample were compared with that for the 125-150#mu#m grains of quartz from the same samples. The results suggested that the K-feldspar equivalent doses were underestimated because of anomalous fading. Measurements of the decay of the IRSL signals following laboratory irradiation for these two samples, and an additional one from a previously published isochron study, showed anomalous fading during the period of laboratory storage. The decay rate was about 3% per decade for all samples and was independent of the grain size used. Using plots of equivalent doses for K-feldspars as a function of their calculated ...
1. The effect of three single doses of nifedipine on exercise-induced asthma has been examined in 11 asthmatic subjects. 2. On four separate days patients undertook 6 min of exercise on a treadmill...Full Text Available
Somatic radiation doses are recognized to be possible factors of carcinogenesis. In correctly performed mammography, however, even as screening test, the radiation dose does not reach such an order of magnitude that the benefit of the procedure as to prevention of breast cancer is called into question.
Based on the replies to a questionnaire distributed throughout Japan in 1983, genetically significant dose (GSD), per Caput mean bone marrow dose (CMD), leukemogenically significant dose (LSD), malignantly significant dose (MSD), and per Caput effective dose equivalent (EDE) from using small sealed radiation sources for radiotherapy were estimated. Annual frequencies of brachytherapy were estimated to be 2.6 x 10"3 for men and 36.3 x 10"3 for women, with a total of 38.9 x 10"3. The annual frequencies of using afterloading technique were 0.3 x 10"3 for men and 18.8 x 10"3 for women, with a total of 19.1 x 10"3. The annual population doses per person were 7.9 nGy for GSD, 118 #mu#Gy for CMD, 19.3 #mu#Gy for LSD, 172 #mu#Gy for MSD, and 428 #mu#Gy for EDE. The annual collective effective dose equivalent was estimated to be 5.13 x 10"4 man Sv. ...
This volume presents the collations tables of a six volume comparative epidemiological survey of the effects of low level radiation dose. Data are collated for the effects observed in the following irradiated groups:- Preconception irradiation, intra-uterine irradiation, childhood irradiation, adult irradiation. (UK).
The genetically significant dose (GSD) is an index variable which exclusively allows to describe the genetic risk in the progeny of a population due to the application of ionizing radiation and radioactive substances in one part of this population. It may result in wrong interpretation of population exposure at increasing incidence of examinations in a population involving ionizing radiation and radioactive drugs at simultaneously increasing application of alternative methods in children and adolescents owing to the fact that it indicates a downward trend although somatic exposure of this population has increased. Therefore, it is recommended to state both the GSD and the level of somatic radiation exposure of the population taken from the individual sources for the comparison and assessment of radiation exposure from various sources in future. Although the somatically significant dose constitutes the suitable variable complementary to GSD in ...
Ionising radiation induces stable free radicals in chicken bones and in the shell of chicken eggs which can be detected, by the electrons spin resonance (ESR) technique, well beyond the shelf-life of the food and can be used for dosimetry. The method usually adopted to evaluate ``a posteriori`` the dose given during the ionising radiation treatment of food, is the dose additive method. To assess the dose, the ESR signal amplitude of the irradiated food (bone or egg shell in the present case) is measured and then the dose-effect relationship is obtained by re-irradiating the sample with some additive doses (usually of 1 kGy). The dose-effect curve is back-extrapolated and the initial given dose determined. At the Istituto Superiore di Sanita (ISS), Rome, Italy, a research programme was approved two years ago aimed to, (1) study new ...
PurposeTo investigate the influence of inhomogeneity corrections on stereotactic treatment plans for non-small cell lung cancer and determine the dose delivered to the PTV and OARs.Full Text Available
An earlier representation of the radial distribution of dose about the path of a heavy ion in liquid water is modified and extended to include silicon, lithium fluoride, and sodium iodide. 6 refs., 5 figs., 1 tab.
Background/AimTobacco use reduces the effect of non-surgical periodontal therapy. Host-modulation with low-dose doxycycline (LDD) might favour repair and promote...Full Text Available
Mixed Uranium Plutonium Carbide ((U, Pu) C), in the form of pellets encapsulated in stainless steel tubes is the fuel for Fast Breeder Test Reactor (FBTR) at Kalpakkam. For the fabrication of fuel for enlarging the core of this reactor, high burn up plutonium is used. The external exposure in these labs was significantly higher than that with low burn up Pu fuel. Dose evaluation to the organs was carried out using experimental TLDs during various operations of FBTR fuel fabrication to study the dose distribution pattern. (author)
The authors give a survey of the somatic radiation risk in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk.
The authors give a survey of the somatic radiation ris in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk. (orig.).
Health physicists from the Brookhaven National Laboratory (BNL) visited the Savannah River Site (SRS) as one of 12 facilities operated by the Department of Energy (DOE) contractors with annual collective dose equivalents greater than 100 person-rem (100 person-cSv). Their charter was to review, evaluate and summarize as low as reasonably achievable (ALARA) techniques, methods and practices as implemented. This presentation gives an overview of the two selected ALARA practices implemented at the SRS: Administrative Exposure Limits and Goal Setting. These dose control methods are used to assure that individual and collective occupational doses are ALARA and within regulatory limits.
Health physicists from the Brookhaven National Laboratory (BNL) visited the Savannah River Site (SRS) as one of 12 facilities operated by the Department of Energy (DOE) contractors with annual collective dose equivalents greater than 100 person-rem (100 person-cSv). Their charter was to review, evaluate and summarize as low as reasonably achievable (ALARA) techniques, methods and practices as implemented. This presentation gives an overview of the two selected ALARA practices implemented at the SRS: Administrative Exposure Limits and Goal Setting. These dose control methods are used to assure that individual and collective occupational doses are ALARA and within regulatory limits.
For over 50 years, electron beams have been an important modality for providing an accurate dose of radiation to superficial cancers and disease and for limiting the dose to underlying normal tissues and structures. This review looks at many of the important contributions of physics and dosimetry to the development and utilization of electron beam therapy, including electron treatment machines, dose specification and calibration, dose measurement, electron transport calculations, treatment and treatment-planning tools, and clinical utilization, including special procedures. Also, future changes in the practice of electron therapy resulting from challenges to its utilization and from potential future technology are discussed. (review)
The paper presents information in the form of data, tables and diagrams compiled to a broad but very up-to-date survey of required radiation for the various most frequently performed X-ray examinations of patients. The required dose is discussed from the point of view of radiation protection, defining the inevitably administered dose to the skin, the frequency of examinations, and the diagnostic image quality as the main three factors to be observed, as these determine the radiation dose to the patient and to the personnel. The somatic risks of radiography examinations are a point of main interest. (DG).
Contributions to the population dose due to medical applications of ionising radiation are presented. It appears that contributions due to radiotherapy and X ray diagnosis are of comparable magnitude. To account for the age dependency of the radiation risks, contributions in terms of somatically significant dose equivalent are calculated as 0.3 mSv per caput per annum for X ray diagnosis and as 0.2 mSv per caput per annum for radiotherapy, the latter referring to only doses to organs outside the target volume. (author).
Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).
Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).
In radiation risk assessment it must be differentiated between somatic and genetic effect on the one hand as well as between stochastic and non-stochastic effect on the other. According to definitions of the ICRP report 26 the limit for the dose equivalent of all tissues prevents non-stochastic radiation effects. With stochastic radiation effects probably exist no threshold doses; therefore the ALARA principle must be applied concerning radiation protection. The individual risk by stochastic radiation effects in its linear, linear-quadratic and quadratic extrapolations, respectively, is discussed in detail. The effective stochastic dose equivalent (H/sub eff/) as well as collective dose and collective damage are outlined.
During one year more than 40,000 items of information on radiation exposure of personnel involved in the handling of radiation sources and more than 5,000,000 items on irradiation of other people are collected in the authors' laboratory. Considerable progress in assessment of mean annual gonad dose of genetically sifnificant dose was attained by means of an algorithm for a personal computer. This simple and inexpensive system has led to a higher accuracy in the application of protective measures. (author).
A compartment model is described which is currently used by the Ministry of Agriculture, Fisheries and Food to calculate collective radiation exposure due to liquid radioactive wastes discharged to sea from UK nuclear sites. Collective dose is a useful indicator of the radiological impact of a disposal practice and is one of the quantities needed to show compliance with the ICRP system of dose limitation. The model has been used for the purposes of the Sizewell Inquiry to predict the collective radiation exposure from reactor operation at Sizewell and, on the basis of current Sellafield experience, correlations between dose and discharge for disposals of fuel reprocessing wastes. (author).