Dose planning and dose delivery in radiation therapy
International Nuclear Information System (INIS)
A method has been developed for calibration of CT-numbers to volumetric electron density distributions using tissue substitutes of known elemental composition and experimentally determined electron density. This information have been used in a dose calculation method based on photon and electron interaction processes. The method utilizes a convolution integral between the photon fluence matrix and dose distribution kernels. Inhomogeneous media are accounted for using the theorems of Fano and O'Connor for scaling dose distribution kernels in proportion to electron density. For clinical application of a calculated dose plan, a method for prediction of accelerator output have been developed. The methods gives the number of monitor units that has to be given to obtain a certain absorbed dose to a point ...
2008-08-01
Absorbed dose and dose equivalent depth distributions for protons with energies from 2 to 600 MeV
Energy Technology Data Exchange (ETDEWEB)
Depth dose distributions for protons in the energy range from 2 to 600 MeV have been calculated by Monte Carlo and analytical methods. The dependence on energy of Maximum Dose Equivalent (MDE), quality factor and isotropic factor recommended for practical use are presented. The problems connected with regulation of maximum permissible proton fluxes are discussed. (author).
1989-01-01
Body dose conversion factors for computerized tomography
International Nuclear Information System (INIS)
While there have been many experimental and calculational investigations on absorbed dose distribution in the patient resulting from conventional X-ray procedures, such data for computerized tomography (CT) are still sparse. As this diagnostic procedure has shown a rapid increase in application during recent years, we have determined absorbed dose to body organs in a human phantom resulting from CT examinations. The exposure model consists of the heterogeneous MIRD-5 phantom and a suitable Monte-Carlo method to calculate absorbed dose to organs of interest. The exposure conditions are specified according to the exposure specifications of a CT-scanner currently in use. The calculations cover the range of body tissues of interest in terms of organ absorbed doses as well as a risk weighted ...
1980-10-31
28: Calculation of 3D dose distribution for photons in inhomogeneous media
International Nuclear Information System (INIS)
A method for calculation of absorbed dose distributions in three dimensions for 1-20 MeV photons is presented. The method uses convolution/superposition of photon fluence distributions with energy scattering kernels. Results for Co-60 and X-ray beams in homogeneous and inhomogeneous media are compared with measurements. Good agreement is found between calculations and measurements. 8 refs.; 3 figs.
Alpha-particle dose distribution effects at the cellular level
International Nuclear Information System (INIS)
Ionizing radiations that differ in number, size, and distribution of energy deposition events might be expected to cause different effects for the same absorbed dose. Furthermore, microdosimetry calculations suggest that large variations in biological effectiveness might be expected for internally deposited alpha-emitting radionuclides for the same absorbed dose, depending upon the specific activity and spatial distribution of the sources in tissue. The study described in this article was designed to demonstrate these phenomena in vitro. Cultured Chinese hamster ovary (CHO-K1 BH4) cells were exposed in vitro to inert, insoluble ceramic microspheres in zirconium dioxide labeled with "2"3"9Pu. The average exit energy of the 5.15 MeV alpha particle was calculated to be 4.3 MeV. Exposure times varied from four to seven hours to achieve the desired ...
1985-02-01
Tertiary-Butanol: A toxicological review
British Library Electronic Table of Contents (United Kingdom)
Tert-Butanol is an important intermediate in industrial chemical synthesis, particularly of fuel oxygenates. Human exposure to tert-butanol may occur following fuel oxygenate metabolism or biodegradation. It is poorly absorbed through skin, but is rapidly absorbed upon inhalation or ingestion and distributed to tissues throughout the body. Elimination from blood is slower and the half-life increases with dose. It is largely metabolised by oxidation via 2-methyl-1,2-propanediol to 2-hydroxyisobutyrate, the dominant urinary metabolites. Conjugations also occur and acetone may be found in urine at high doses. The single-dose systemic toxicity of tert-butanol is low, but it is irritant to skin and eyes; high oral doses produce ataxia and hypoactivity and repeated exposure can induce dependence...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
A thermoluminescence (TL) sheet and its spatial readout system for in vivo measurement of spatial dose distribution around sources has been newly developed for intracavitary high dose-rate radiation therapy. The TL sheet (40 cm x 50 cm x 200 {mu}m), which is composed of teflon mixed with BaSO{sub 4} (Eu doped) powder, has a linear response with a very wide dynamic range from at least 0.002 cGy to 5000 cGy for {sup 60}Co sources. Phantom test of the TL sheet readout system demonstrated that absorbed dose with TL sheet and that with ionization chamber as standard dosimeter agreed well. For clinical application, TL sheet was attached on an applicator of intracavitary radiation therapy for rectal cancer. After irradiation with high dose-rate {sup 60}Co sources, the in vivo dose distribution on the surface of the rectum was ...
1991-06-01
Determination of absorbed dose in a patient irradiated by beams of x or gamma rays in radiotherapy procedures
1976-01-01
Dosimetry of iodine-123 iomazenil in humans
International Nuclear Information System (INIS)
The distribution of the central benzodiazepine receptor specific ligand iodine-123 iomazenil was investigated in seven human adults from whole-body scans, blood samples and urine collected up to 24 h after injection. Using 12 source organs, the MIRD method was applied to calculate the absorbed radiation dose of the radioligand in various organs. The urinary bladder wall (0.15 mGy/MBq), lower large intestinal wall (0.071 mGy/MBq) testes (0.044 mGy/MBq) and upper large intestined wall (0.038 mGy/MBq) received the highest absorbed doses. The average effective dose equivalent of "1"2"3I-IBZM for adults was estimated to be 0.033 mSv/MBq. (orig.).
Optimization of segment weight using simulated dynamics algorithm for beamlet-based IMRT
International Nuclear Information System (INIS)
With accurate calculation algorithms in inverse planning for beamlet-based intensity modulated radiotherapy (IMRT), it takes time to calculate the dose matrix, which represents the dose distribution of each beamlet element to each voxel for unit fluence. To reduce the calculation time, coarse or approximate algorithms are often a choice, but this results in a final dose distribution that cannot reflect the real value. In addition, it is necessary to test if a coarse algorithm is capable of calculating the dose matrix of beamlets. In this work, simulated dynamics optimization algorithm was applied to optimize the segment weight to minish the dose error from the dose matrix calculation. After calculating the dose matrix by ray-tracing algorithm which takes into account just the primary component of ...
2007-08-01
International Nuclear Information System (INIS)
Techniques for reducing computation time in 3D photon dose calculations are addressed with specific emphasis given to the convolution/superposition approach. A single polyenergetic superposition model calculating absorbed dose per incident photon fluence (Gy cm"2) was developed in terms of TERMA and a total energy deposition kernel (a total point spread function). A novel approach was devised for reducing calculation time. The method, named the CF method, was based on the use of a conventional, fast model (here a modified power-law method was used) for the generation of 3D dose distributions on a fine dose matrix. Superposition calculations were carried out on a coarse matrix and calculation speed was increased simply by reducing the number of calculations. A set of correction factors was derived on the coarse grid from the ratio of the dose ...
1997-08-01
Tumour control probability (TCP) for non-uniform activity distribution in radionuclide therapy
Energy Technology Data Exchange (ETDEWEB)
Non-uniform radionuclide distribution in tumours will lead to a non-uniform absorbed dose. The aim of this study was to investigate how tumour control probability (TCP) depends on the radionuclide distribution in the tumour, both macroscopically and at the subcellular level. The absorbed dose in the cell nuclei of tumours was calculated for {sup 90}Y, {sup 177}Lu, {sup 103m}Rh and {sup 211}At. The radionuclides were uniformly distributed within the subcellular compartment and they were uniformly, normally or log-normally distributed among the cells in the tumour. When all cells contain the same amount of activity, the cumulated activities required for TCP = 0.99 (A-tilde{sub TCP=0.99}) were 1.5-2 and 2-3 times higher when the activity was distributed on the cell membrane compared to in the cell ...
2008-08-21
Analysis on Dose Distribution in Heterogeneous Condition for Narrow 6 MV X-ray Beams
International Nuclear Information System (INIS)
Advanced modality of high-precision radiotherapy fulfilled by a composition of large numbers of small field beams called 'beamlets' can be achieved via nonuniform intensity fluencies. In case of radiation measurements and calculations with narrow high-energy photon beams, however, an accurate two-dimensional dosimetry is a challenging task due to dosimetrically unfavorable phenomena such as dramatic changes of the dose at the field boundaries, dis-equilibrium of the electrons resulting from larger detector volume, and non-uniformity between the detector and the phantom materials. Meanwhile, with the advantages of high spatial resolution and wide range of absorbed doses, there is a growing demand of GAFCHROMICat..EBT film to confirm delivered dose distribution. Especially, the effects from the material differences between the phantom and the film can be minimized in the heterogeneous ...
2010-10-01
Energy Technology Data Exchange (ETDEWEB)
The importance of cellular dosimetry in both diagnostic and therapeutic nuclear medicine is becoming increasingly recognized. Experimental range-energy relations for electrons and alpha particles, along with derived geometric reduction factors, are used to calculate cellular absorbed fractions for these radiations. The resulting absorbed fractions are employed to calculate cellular S-values for several radionuclides. Cellular absorbed fractions for monoenergetic electron sources with energies ranging from 0.1 keV to 1 MeV, distributed uniformly in the source region, are calculated for several target {l_arrow} source combinations including cell{l_arrow}cell, cell{l_arrow}cell surface, nucleus{l_arrow}nucleus, nucleus {l_arrow}cytoplasm and nucleus {l_arrow}cell surface. Similar data are also provided for monoenergetic alpha particle sources with energies ranging from 3 to 10 MeV. S-values are also ...
1994-02-01
Determinations of organ or tissue doses to survivors in Hiroshima and Nagasaki
International Nuclear Information System (INIS)
For the purpose of risk estimates from radiation carcinogenesis including leukemogenesis and radiation genetic effects, the biological significant dose is not the tissue kerma in air but the absorbed dose in organ or tissue with respect to carcinogenic and leukemogenic effects or genetic effects. In order to estimate organ or tissue dose from the tissue kerma in air, a ratio of the organ or tissue dose to the tissue kerma in air for survivors in Hiroshima and Nagasaki was calculated with the aid of the Snyder's mathematical phantoms constructed so as to simulate the body shape of survivors aged 5, 10 years old and adult at the time of atomic bomb detonations. The ratios were corrected for the angular distribution of atomic bomb radiations, assuming an anisotropic angular distribution for the survivors exposed to the atomic bombs in open air ...
1980-01-01
Absorbed dose and dose reduction in mammography
International Nuclear Information System (INIS)
First, absorbed dose at entrance surface was measured in routine mammography. Secondly, a possibility of dose reduction after introduction of Fuji computed radiography (FCR) system was examined. In a total of 350 mammographic studies including craniocaudal and medilateral projections, average thickness of compressed breast was less than 4 cm and most frequently recorded absorbed dose was 0.2-0.3 cGy (200-300 mrad). Minimum dose to obtain clinically acceptable mammograms in FCR system was estimated by comparing image quality of routine versus reduced dose studies. It was concluded that absorbed dose could be reduced to 1/4 of routine dose without creating significant drawback in diagnosis. (author).
1986-01-01
International Nuclear Information System (INIS)
A number of procedures in diagnostic radiology and cardiology make use of long exposures to x-rays from fluoroscopy units. Although numerous studies have been performed to measure or calculate skin dose from these procedures, there have only been a handful of studies to determine the dose to the other organs. This thesis was focused on devising a method to calculate the absorbed dose to underlying tissues and organs. The work was performed in several stages. First, a commercial convolution/superposition-based treatment planning system used in radiation oncology was modified and complemented to make it usable with the low energies of x-rays used in diagnostic radiology. This required generation of energy deposition kernels in the kilovoltage energy range. The kernels were generated using the EGS4 Monte Carlo system of codes and added to the treatment planning system. The treatment planning system was ...
2001-03-01
Energy Technology Data Exchange (ETDEWEB)
Graft copolymerization of sodium styrene sulfonate (SSS) onto electron beam (EB) irradiated poly(vinylidene fluoride) (PVDF) films was investigated to find out a simple preparation process for sulfonic acid proton exchange membranes with respect to monomer concentration, absorbed dose, temperature, film thickness and storage time. The reaction order of the monomer concentration and absorbed dose of grafting was found to be 2.84 and 1.20, respectively. The overall activation energy for graft copolymerization reaction was calculated to be 11.36 kJ/mol. The initial rate of grafting was found to decrease with an increase in the film thickness. The trapped radicals in the irradiated PVDF films remained effective in initiating the reaction without considerable loss in grafting level up to 180 days, when stored under -60 {sup o}C. The presence and distribution of polystyrene sulfonate ...
2011-01-15
International Nuclear Information System (INIS)
Magnetic particles (MAG*SEP"S"M) coated with various absorbents were evaluated for the separation and recovery of low concentrations of cesium from nuclear waste solutions. The MAG*SEP"S"M particles were coated with (1) clinoptilolite, (2) transylvanian volcanic tuff, (3) resorcinol formaldehyde, and (4) crystalline silico-titanate, and then were contacted with a Hanford supernatant simulant. Particles coated with the crystalline silico-titanate were identified by Bradtec as having the highest capacity for cesium removal under the conditions tested (variation of pH, ionic strength, cesium concentration, and absorbent/solution ratio). The MAG*SEP"S"M particles coated with resorcinol formaldehyde had high distribution ratios values and could also be used to remove cesium from Hanford supernant simulant. Gamma irradiation studies were performed on the MAG*SEP"S"M particles with a gamma dose equivalent to ...
1994-05-09
Lead and calcium distributions in blood, plasma, and milk of the lactating mouse
Energy Technology Data Exchange (ETDEWEB)
Although it has been established that lead is transferred in milk from mother to suckling offspring, the physiological processes and parameters involved are not well understood. Single i.v. doses (0.2 mg/kg) or p.o. doses (2 mg/kg) of radiolabeled lead were administered to lactating and nonlactating female mice, and lead concentrations in blood, plasma, and milk were determined during a 21-day period. Large differences in lead elimination were observed between lactating and nonlactation mice. A significant fraction (25%) of the initial maternal dose (absorbed dose) was transferred to the suckling pups. The ratio of lead concentration in milk to lead concentration in plasma was found to be nearly constant over time. However, the milk-to-blood concentration ratios decreased during the same period. Furthermore, the concentration of lead in milk exceeded the plasma concentration by a ...
1980-01-01
Energy Technology Data Exchange (ETDEWEB)
Gel dosimetry is a new dosimetry method applied in radiation therapy. Gel dosimeters consist of a radiation sensitive gel, which can integrate absorbed doses from several radiation sources or beams. The dose to the gel can be evaluated by magnetic resonance imaging (MRI), a procedure that is the focus of the present thesis. A robust tool for the evaluation of the nonuniformity in MRI has been developed, the Deviation Image method. Unlike previously presented methods, the Deviation Image method includes all nonuniformity variations across a phantom surface and is insensitive to stochastic noise. Methods for the estimation of stochastic noise were analyzed in terms of sensitivity to nonuniformities. A method that averages the stochastic noise level over five regions over the phantom surface, and a method that assesses the stochastic noise level from the background, were found to be the methods of choice. Pronounced MR image ...
2001-03-01
A somatic dose index for diagnostic radiology
International Nuclear Information System (INIS)
Irradiation of the human body in diagnostic X-ray procedures results in different absorbed doses in the various body organs. A somatic dose index in formulated by applying the relative sensitivity of the human to each of the most important somatic effects and utilizing the absorbed dose in the affected organs. This quantity is used to convey a cumulative somatic impact and is computed for common radiographic views in diagnostic radiology as a function of beam quality for a nominal IR entrance exposure. Using typical X-ray beam qualities and exposures, the frequency of the various radiographic views that make up an examination and the frequencies of the various examinations in the national population, illustrative examples of the application of the somatic dose index are presented. (author).
1978-01-01
International Nuclear Information System (INIS)
Processing of food with ionizing radiation is a method suitable to enhance shelf-life and hygienic quality. Up to a dose of 10 kGy the method is considered wholesome. In many countries the practical use of food irradiation is increasing, however, in the Federal Republic of Germany the process is strictly forbidden. Applications and methods for radiation processing of food are compiled, limits and prospects are explained, and advantages and disadvantages are compared with traditional methods. Identification of irradiated foods and dosimetry and process control for radiation processing of food are areas where further research is needed. Continuous processing of particulate foods in bulk is an application where electron accelerators might be profitable. Beam parameters and velocity distribution of food particles in the treatment area can be matched for an effective result. Thus, dose distribution can be ...
A TLD powder dosimetry measurement system for physical models of reference man
International Nuclear Information System (INIS)
A tissue-equivalent dosimetry system has been developed for use in absorbed dose determinations with physical models of Reference Man. The dosimeter used was a thermo-luminescent dosimeter (TLD) powder which was mixed with a 'tissue-equivalent' material and modeled to closely approximate an organ's geometry and absorption properties. A separation procedure was developed by which the TLD powder was washed and the 'tissue-equivalent' material, a wax, was dissolved and extracted following the irradiation of the model. The procedure was tested to determine losses of powder, homogeneity of the powder's distribution throughout the wax, the effects of the separation procedure upon the powder and the statistical behavior of the procedure. The results of these tests established the feasibility of the procedure. A full-scale model of the pancreas was tested and the results supported the validity of the technique. (author)
1978-12-01
Method of describing dose distributions in computer design of teleradiotherapy
International Nuclear Information System (INIS)
Method for description of X-ray radiation dose distribution based on semiempirical description of dose fields is suggested. At that dose field description parameters can be easily individualized for concrete X-ray device.
Electron Beam and Gamma Radiolysis of Solid-State Metoclopramide
British Library Electronic Table of Contents (United Kingdom)
Purpose Study the radiolysis of solid-state metoclopramide hydrochloride at various absorbed doses. Elucidate the structure of the degradation products to gain information on the radiolysis mechanisms. Methods Solid-state metoclopramide samples were irradiated at several doses with gamma rays and high-energy electrons to evaluate the influence of the dose rate. High-performance liquid chromatography with a diode array detector was used to measure the chemical potency as a function of the absorbed dose and to quantify the degradation products. The characterization of degradation products was performed by liquid chromatography/atmospheric pressure chemical ionization/tandem mass spectrometry. Results The degradation of solid-state metoclopramide after irradiation was negligible. No qualitati...
2006-01-01
A water calorimeter for high energy x-rays and electrons
The current primary standards at NPL for the measurement of absorbed dose to water in high energy photon and electron beams are graphite calorimeters. However, the quantity of interest in radiation dosimetry is absorbed dose to water. Therefore, a new absorbed dose to water standard based on water calorimetry has been developed for use in high energy photon and electron beams. The calorimeter operates at 4 deg C, with temperature control being provided by liquid cooling. The sealed glass inner vessel of the calorimeter was designed to minimise the effect of non-water materials on the measurement of absorbed dose. The temperature sensing thermistor probes were designed and constructed so that glass is the only material in contact with high purity water inside the vessel. Initial measurements of ...
2000-01-01
Energy Technology Data Exchange (ETDEWEB)
The distribution of carrier free lead-203 between plasma and cells of canine blood in vitro was measured. Activity in the plasma decreased to less than 5% of the initial blood activity during the first 15 min and then exponentially with a half time of 160 min. Incubation in cell free plasma before addition to whole blood transformed the isotope, decreasing the amount subsequently associated with cells. In animal studies, activity was measured in plasma, blood cells, urine, and feces after exposure to lead-203. In one group, the animals were exposed by intravenous injection of dilute citric acid solutions of isotope. In a second group, carrier free isotope which had been transformed by incubation in plasma was injected intravenously. The kinetics of the distribution of the isotope differed between the two experimental groups. After injection of the transformed lead, the lead-203 content of the blood cell fraction rose from 10% of the ...
1980-01-01
Preparation of wood-polymer composites using radiation
International Nuclear Information System (INIS)
Wood-polymer composites (WPC) have been prepared of pinewood with different monomers using Gamma radiation: acrylamide, butyl acrylate, butyl methacrylate, styrene, acrylonitrile, and polyester. The polymer loading was determined as a function of monomer concentration and absorbed dose. The data show that polymer loading increases by increasing the monomer concentration. In two cases, BMA and polyester, the polymer loading decreases at high concentrations. This can be explained by the increase of the viscosity. Thus the diffusion of the compound into bulk would be slower. The absorbed dose seems to play a positive role in enhancing the polymer loading by increasing the dose. The mechanical properties, tensile and compression strength, have been improved in the most cases for all monomer concentrations or absorbed doses. Using polyester there ...
1976-11-25
Multicellular level dosimetry and low dose rate effects
International Nuclear Information System (INIS)
Building on the concepts of MIRD methods described by Webber, Watson and others at this Symposium on the Dosimetry of Administered Radionuclides, we will now consider how to apply these principles to several experimentally based open-quote macroclose quotes and multicellular models. Specifically, methods to calculate absorbed dose using different types of particulate emission (alpha, beta) with a variety of antibody carriers (IgG, F(ab')_2, Fab) for radioimmunotherapy (RIT) will be reviewed. Additionally, a discussion of direct measurement methods at the multicellular level will reveal the problems of tumor absorbed dose heterogeneity when applied to animal and clinical studies.
1989-09-21
Clinical application of dosimetry in electron beam therapy
International Nuclear Information System (INIS)
In everyday radiotherapy we must carry out the determination of absorbed dose measurement according to JARP's protocol. We explained an outline of JARP's 1974 and 1986 protocol in electron beam therapy, and mentioned it about the matter that should examined. To use it easily in clinic, a simplified procedure based on precisely to JARP's 1986 protocol is practical, the character of this procedure settles briefly the determination of mean incident energy of electron beams and get ready to table of ionization to absorbed dose conversion factor for various ionization chamber. Also, this procedure almost not influence on the accuracy of determination. We described systematically practical procedure for requisite absorbed dose calculation in a patient in electron beam therapy. (author).
Energy Technology Data Exchange (ETDEWEB)
The performance of PAN-based composite absorbers was evaluated in dynamic experiments at flow rates ranging from 25--100 bed volumes (BV) per hour. Composite absorbers with active components of ammonium molybdophosphate (AMP) PAN and K-Co ferrocyanide (KCoFC) PAN were used for separating Cs from a 1 M HNO{sub 3} + 1 M NaNO{sub 3} + 2 {times} 10{sup {minus}5} M CsCl acidic simulant solution. KCoFC-PAN and two other FC-based composite absorbers were tested for separating Cs from alkaline simulant solutions containing 0.01 M to 1 M NaOH and 1 M NaNO{sub 3} + x {times} 10{sup {minus}4} M CsCl. The efficiency of the Cs sorption on the AMP-PAN absorber from acidic simulant solutions was negatively influenced by the dissolution of the AMP active component. At flow rates of 50 BV/hr, the decontamination factor of about 10{sup 3} could be maintained for treatment of 380 BV of the feed. With the KCoFC-PAN ...
1996-05-01
Dosimetry in dental radiology. Dentascan spiral CT versus panoramic radiography
International Nuclear Information System (INIS)
The study compares the doses absorbed by the dentomaxillary area in spiral CT and panoramic examinations. The dose measurements demonstrate that patients receive smaller doses with panoramic radiography than with spiral CT with Dentascan. After following for some variations from instrumental differences, they are in substantial agreement with literature data. Further investigations are needed considering the radiobiological risk related to the growing spread of Dentascan examinations.
1999-05-01
International Nuclear Information System (INIS)
The purpose of this study is to evaluate the accuracy of dose calculations by three algorithms. Depth dose, OPF (Output Factor) and dose profiles were measured in a heterogeneous phantom. These values were also calculated by three algorithms of the Batho power law (BPL), Equivalent-Tissue Air Ratio (ETAR) and Convolution superposition (CS). The data were obtained for 4, 6 and 10 MV photon beams with a linear accelerator (Varian 21EX). Field size ranged from 3 x 3 cm"2 to 10 x 10 cm"2. Dose profiles of beam penumbra were also measured by a 0.125 ml ionization chamber at the point of 8, 13 and 18 cm from the surface of the phantom at intervals of 1 mm. Differences between measured and calculated depth doses were within 2% in BPL and CS, but depth doses were overestimated in ETAR. OPFs were also overestimated with the error of more than 4% in ETAR. ...
2004-12-01
Medical irradiation and the use of the 'effective dose equivalent' concept
International Nuclear Information System (INIS)
By applying the linear-dose effect relation, the weighting factors for total risks recommended by IRCP can be transformed to weighting factors for somatic effects. Another weighting factor Msub(s) has to be used which takes into account the dependence of the latent period for occurrence of malignant disease and the variation of the incidence with time. On this basis a somatically significant dose equivalent can be defined as 'the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by the various individuals', and an approximation has been derived for this. Tables are presented of the somatic effective dose equivalents calculated for different x-ray examinations for various organs and tissues. The S.E.D. equivalents have also been calculated for ...
1980-03-01
Estimation of X-rays dose in the crystals of final thickness
International Nuclear Information System (INIS)
A calculation method of the X-ray radiation dose (energy of gamma- radiation remains in the range of energies where the mechanism of photoelectric absorption is the prevailing one) absorbed in the absorbers of final thickness is suggested. Calculations of resorption of secondary radiation (characteristic fluorescences) in the substance and kinetic energy of photoelectrons caused by this resorption (it would be enough to consider one or two hard series) are presented. Calculation of the spectrum of photoelectron energy yield in TeInSe_2 monocrystal for 0.1-0.5 A range of X-ray radiation is conducted by the developed methods.
On the Impact of Longitudinal Breathing Motion Randomness for Tomotherapy Delivery
UK PubMed Central (United Kingdom)
The purpose of this study is to explain the unplanned longitudinal dose modulations that appear in helical tomotherapy (HT) dose distributions in the presence of irregular patient breathing....Full Text Available
2008-09-21
Energy Technology Data Exchange (ETDEWEB)
Natural radioactive materials under certain conditions can reach hazardous radiological levels. The natural radionuclide ({sup 238}U, {sup 232}Th, {sup 40}K) contents of rock samples at various locations in the North Tushki area were investigated using gamma-spectrometric analysis. Estimates of the measured radionuclide content have been made for the absorbed dose rate of gamma radiation. The equivalent radium (R{sub eq}) and the external hazard index (H{sub ex}) which resulted from the natural radionuclides in soil are also calculated and tabulated. The studied samples have been collected from various rock exposures in the North Tushki area. The distribution of major oxides, U and Th were studied. It is found that the enrichment and depletion of the major oxides are mainly due to the effect of hydrothermal alteration, which caused mobility of some major oxides, which increases some elements and decreases others. It is ...
2002-09-01
International Nuclear Information System (INIS)
International standards and guidelines for calibrating high-dose dosimetry systems to be used in industrial radiation processing recommend that dose-rate effects on dosimeters be evaluated under conditions of use. This is important when the irradiation relies on high-current electron accelerators, which usually provide very high dose-rates. However, most dosimeter calibration facilities use low-intensity gamma radiation or low-current electron accelerators, which deliver comparatively low dose-rates. Because of issues of thermal conductivity and response, portable calorimeters cannot be practically used with high-current accelerators, where product conveyor speeds under an electron beam can exceed several meters per second and the calorimeter is not suitable for use with product handling systems. As an alternative, Monte Carlo calculations can give theoretical estimates of the ...
2007-08-01
On the accuracy and effectiveness of dose reconstruction for tomotherapy
International Nuclear Information System (INIS)
Dose reconstruction is a process that re-creates the treatment-time dose deposited in a patient provided there is knowledge of the delivered energy fluence and the patient's anatomy at the time of treatment. A method for reconstructing dose is presented. The process starts with delivery verification, in which the incident energy fluence from a treatment is computed using the exit detector signal and a transfer matrix to convert the detector signal to energy fluence. With the verified energy fluence and a CT image of the patient in the treatment position, the treatment-time dose distribution is computed using any model-based algorithm such as convolution/superposition or Monte Carlo. The accuracy of dose reconstruction and the ability of the process to reveal delivery errors are presented. Regarding accuracy, a reconstructed dose ...
2001-04-01
Mammary carcinogenesis in the rat after low-dose irradiation
International Nuclear Information System (INIS)
Carcinogenesis is now generally recognized to be an important detrimental effect in man after low dose irradiation. The carcinogenic action of ionizing radiation is clearly demonstrated after exposure to relatively high doses (in excess of 0.5 Gy) but for lower dose levels reliable direct observations are not available. With the introduction of special protocols for the performance of large scale screening programs by mammography the average absorbed dose in glandular tissue in the average breast can be restricted to a value of 3 mGy per mammogram. The risk for tumor induction after exposure to these low doses can never be established from human epidemiology. In order to investigate the risk of repeated exposure to small dose of ionizing radiation the induction of mammary tumors has been investigated in rats of the WAG/Rij strain after ...
1992-07-12
International Nuclear Information System (INIS)
An earlier representation of the radial distribution of dose about the path of a heavy ion in liquid water is modified and extended to include silicon, lithium fluoride, and sodium iodide. 6 refs., 5 figs., 1 tab.
1989-09-01
The result of Alanine/ESR dosimetry at Wolsung unit 1
International Nuclear Information System (INIS)
It needs accurate estimation of radiation level for verifying machinery and cable in Nuclear Power Plant. Therefore, in this study, we used ESR(Electron Spin Resonance) system for estimate dose of Alanine dosimeter. Alanine/ESR dosimetry, already known as a dosimetric method in medical and industrial field, was applied to estimate dose quantity at cable locations within a nuclear power plant as a part of equipment qualification program. Alanine/ESR dosimetry of absorbed dose range is 1 - 100 KGy. The alanine dosimeter is not significantly affected by temperature and fading is limited to 1% per year. The alanine dosimeters were fixed on the targeted cable or nearest position to measure dose quantity to get accurate value. Alanine dosimeters were scanned by commercially used two different ESR systems, e-scan and EMX series for alanine dosimeters. To estimate more accurate ...
2008-10-01
UK PubMed Central (United Kingdom)
Voxel-based prescriptions of deliberately non-uniform dose distributions based on molecular imaging, so-called dose painting or theragnostic radiation therapy, require specification of a transformation...Full Text Available
2009-03-21
International Nuclear Information System (INIS)
The decree refers to conditions of irradiation of food and its components for radappertization and radurization using gamma radiation from cobalt 60 or cesium 137, X radiation or electron beam up to maximum total medium absorbed dose 10 kGy.
2003-03-04
Radioactive lead studies in the human
International Nuclear Information System (INIS)
The differing susceptibility of individuals to the toxic effects of chronic lead exposure has never been fully understood. As the major intake of lead in the human is from food and beverages, any variation between individuals of the quantity of lead absorbed from the gut, and of the distribution and excretion of this lead, may account for the differences in individual susceptibility. The food and beverages themselves may have an influence, and to investigate their effects on absorption, distribution and excretion of lead, experiments were performed on normal subjects using a short lived radionuclide of lead, "2"0"3Pb, and instruments generally available in Nuclear Medicine. Lead absorption between different individuals showed a wide variation when "2"0"3Pb was taken as a single dose between meals. Minerals were found to be mainly responsible for affecting absorption when one subject ingested "2"0"3Pb in ...
Dose verification using a pelvic phantom in high dose rate (HDR) brachytherapy
Energy Technology Data Exchange (ETDEWEB)
High dose rate (HDR) brachytherapy for treating a cervix carcinoma has become popular, because it eliminates many of the problems associated with conventional brachytherapy. In order to improve the clinical effectiveness with HDR brachytherapy, a dose calculation algorithm, optimization procedures, and image registrations need to be verified by comparing the dose distributions from a planning computer and those from a humanoid phantom. In this study, the humanoid phantom was fabricated in order to verify the absolute doses and the relative dose distributions. The measured doses from the humanoid phantom were then compared with the treatment planning system for the dose verification. The humanoid phantom needs to be designed such that the dose distributions ...
2003-07-01
Radiation testing of organic ion exchange resins
International Nuclear Information System (INIS)
A number of ion exchange materials are being evaluated as part of the Tank Waste Remediation System (TWRS) Pacific Northwest Laboratory (PNL) Pretreatment Project for the removal of "1"3"7Cs from aqueous tank wastes. Two of these materials are organic resins; a phenol-formaldehyde resin (Duolite CS-100) produced by Rohm and Haas Co. (Philadelphia, Pennsylvania) and a resorcinol-formaldehyde (RF) resin produced by Boulder Scientific Co. (Mead, Colorado). One of the key parameters in the assessment of the organic based ion exchange materials is its useful lifetime in the radioactive and chemical environment that will be encountered during waste processing. The focus of the work presented in this report is the radiation stability of the CS-100 and the RF resins. The scope of the testing included one test with a sample of the CS-100 resin and testing of two batches of the RF resin (BSC-187 and BSC-210). Samples of the exchangers were irradiated with a "6"0Co source to a total ...
1983-04-11
Radiation testing of organic ion exchange resins
Energy Technology Data Exchange (ETDEWEB)
A number of ion exchange materials are being evaluated as part of the Tank Waste Remediation System (TWRS) Pacific Northwest Laboratory (PNL) Pretreatment Project for the removal of {sup 137}Cs from aqueous tank wastes. Two of these materials are organic resins; a phenol-formaldehyde resin (Duolite CS-100) produced by Rohm and Haas Co. (Philadelphia, Pennsylvania) and a resorcinol-formaldehyde (RF) resin produced by Boulder Scientific Co. (Mead, Colorado). One of the key parameters in the assessment of the organic based ion exchange materials is its useful lifetime in the radioactive and chemical environment that will be encountered during waste processing. The focus of the work presented in this report is the radiation stability of the CS-100 and the RF resins. The scope of the testing included one test with a sample of the CS-100 resin and testing of two batches of the RF resin (BSC-187 and BSC-210). Samples of the exchangers were irradiated with a {sup 60}Co source to a total ...
1995-09-01
Retrospective individual dosimetry using luminescence and EPR after radiation accidents
International Nuclear Information System (INIS)
In areas where radiation dose monitoring has not been performed, it is essential to use material available in the environment be able to rapidly assess doses to individuals for immediate emergency medical care or for general estimation of the radiological consequences. It was shown that certain types of telephone cards containing microchips have the potential to be used as individual radiation dosimeters in emergency situations to detect doses over 250 mGy by luminescence measurements. In order to understand the dosimetric properties of chip cards, the components obtained from INFINIEON Company at various stages of production were used for luminescence measurements. It is found that the protecting layer used above the chips so called 'globe top' is the main source of radiation induced signal in chip cards. The globe top produced by INFINIEON at that stage is found to contain SiO2 and Epoxy. In order to improve the ...
INTRINSIC DOSIMETRY: A POTENTIAL NEW TOOL FOR NUCLEAR FORENSICS INVESTIGATIONS
International Nuclear Information System (INIS)
Thermoluminescence (TL) dosimetry was used to measure dose effects on the raw stock material of borosilicate container glass from different geographical locations. Effects were studied at times up to 60 days post-irradiation at doses from 0.15 to 20 Gy. The minimum detectable dose using this technique was estimated to be 0.15 Gy which is roughly equivalent to a 24 hr irradiation 1 cm from a 50 ng source of 60Co. Two peaks were identified in the TL glow curve, a relatively unstable peak around 125 C and a more stable peak around 225 C. Differences in TL glow curve shape and intensity were also observed for the glasses from different geographical origins. We investigate radiation induced defects in glass to further develop the technique of intrinsic dosimetry - the measurement of the total absorbed dose received by the walls of a container holding radioactive material. Intrinsic ...
2010-07-11
Calculating electron dose using a convolution/superposition method. 120
International Nuclear Information System (INIS)
The calculation of electronn beam dose using an algorithms similar to convolution/superposition methods for photon beams [1,2,3,4] is explored. The distribution of dose deposited by a number of monoenergetic, point-monodirectional electron pencil beams is first determined using the Monte Carlo method [5,6]. These elementary distributions are combined to model distributions that would result from the spectrum of incident energies and angles [6,7] present in a clinical beam. These modified distributions are then stored for use as kernels in the dose calculation. In the case of a homogeneous phantom, the relative fluence distribution is convolved with the stored kernels to obtain thhe dose distributions in 3 dimensions. Since the kernels cannot be assumed to be spatially invariant ...
Coloring of cultured pearls by gamma-rays irradiation
International Nuclear Information System (INIS)
Changing cream pearls into bluish-grey by #gamma# ray irradiation is a technique in coloring of pearls. Irradiated pearls are similar in color to cultured blue pearls. The pearl layers hardly change their color but the nuclei change into dark brown by irradiation. Visible light (500 - 700 nm) penetrating the pearl layer is absorbed by dark brown nucleus. The intensity of reflecting light between 400 and 500 nm at pearl surface, therefore, becomes stronger than that between 500 and 700 nm; therefore color of irradiated pearls look bluish-grey. The density of bluish-grey color increases with increasing absorbed doses, but their luster at surface diminishes owing to the deterioration of the pearl layer by prolonged irradiation; high doses irradiation should be avoided. Irradiated pearls show no substantial fading of their color in a year and the rate of the fading is found to be lower than that for ...
Energy Technology Data Exchange (ETDEWEB)
To date, no single passive detector has been found that measures dose equivalent from ionizing radiation exposure in low-Earth orbit. We have developed the I.S.S. Passive Dosimetry System (P.D.S.), utilizing a combination of TLD in the form of the self-contained Pille TLD system and stacks of CR-39 plastic nuclear track detector (P.N.T.D.) oriented in three mutually orthogonal directions, to measure total dose and dose equivalent aboard the International Space Station (I.S.S.). The Pille TLD system, consisting on an on board reader and a large number of Ca{sub 2}SO{sub 4}:Dy TLD cells, is used to measure absorbed dose. The Pille TLD cells are read out and annealed by the I.S.S. crew on orbit, such that dose information for any time period or condition, e.g. for E.V.A. or following a solar particle event, is immediately available. Near-tissue equivalent CR-39 ...
2006-07-01
Prediction of drug particle size and content uniformity in low-dose solid dosage forms
British Library Electronic Table of Contents (United Kingdom)
Drug particle size distribution has a profound impact to the content uniformity in low-dose solid drug products. We derived theoretically the skewness of potency distribution as a function of particle size distribution and target dose. It was demonstrated that both skewness and coefficient of variation diverge simultaneously with inverse square root of the target dose. This scaling relation was observed in recent experiment and was verified by Monte Carlo (MC) simulation, which was employed for the first time to solve for the full potency distribution from a random retrieving model. When tested against the criteria from USP uniformity of dosage units, MC simulation showed a striking anisotropic distribution of the data. This suggests a full-scale consideration of the potency distribu...
2010-01-01
Organ doses and integral doses in X-ray diagnosis of the chest and of the head
International Nuclear Information System (INIS)
Organ and tissue doses and integral doses in patients due to diagnostic x-ray examinations of the chest and of the head will be presented. These data have been obtained by measuring the dose distributions in man phantoms by LiF-dosimetry. The data will be compared with data obtained by Monte-Carlo calculations. To obtain average organ doses for a special type of examination for the population or for a specified subpopulation in the variation of the exposure, data due to the different techniques used by the different radiologists has to be known. Such data will be presented. The results of the investigation will be discussed in connection with the concept of the 'somatic significant.
1977-04-01
Energy Technology Data Exchange (ETDEWEB)
LEDF(Large Equipment Dismantling Facility) is the solid waste processing technology development facility that carries out high-volume reduction and low dosage processing. The high-volume reduction processing of the high dose {alpha}-waste configured with combustible waste, pvc and rubber, spent ion exchange resin, and noncombustible waste have been planned the incinerating and melting facility using the in-can type high frequency induction heating in LEDF. This test is intended to clarify the design data. It was confirmed that the incinerating and melting performance, molten solid properties and exhaust gas processing performance with pilot testing equipment and bench scale equipment. The result of this test are as follows. 1. Processing speed is 6.7 kg/h for the combustible waste, 13.0 kg/h for the ion exchange resin, and 30.0 kg/h for the noncombustible waste. For above optimum processing conditions are as follows. Operating temperature is 1000degC for the ...
1999-12-01
An integrated Tomographic Gamma Scanning system for non-destructive assay of radioactive waste
Energy Technology Data Exchange (ETDEWEB)
The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm{sup -3} or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant applications. Many of the design features and the end application itself ...
2007-08-21
An integrated Tomographic Gamma Scanning system for non-destructive assay of radioactive waste
International Nuclear Information System (INIS)
The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm"-"3 or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant applications. Many of the design features and the end application itself set ...
2007-08-21
Paediatric radiography - the avoidance of late radiation damage to the growing hip
Energy Technology Data Exchange (ETDEWEB)
Epiphyseal plates of growing bones are sensitive to ionizing radiation and this poses problems for the paediatric radiotherapist. In this case report we describe a child in whom electron beam therapy to the groin delivered only low dose radiation to the proximal hip epiphyses - 130 cGy fractionated over 5 weeks - but who suffered late maldevelopment. We explore the success of various radiotherapy techniques in minimizing the dose to the hip epiphyses in four other children. The appropriate positioning of the limb, the choice of treatment modality and, where possible, individual shielding blocks are considered and their effect on the dose to the hip estimated. Absorbed doses of radiation delivered to the midpoint of the proximal femoral epiphyses have been retrospectively determined. (author).
1993-04-01
The use of calcium silicate bricks for retrospective dosimetry
International Nuclear Information System (INIS)
The suitability of calcium silicate bricks (CSBs) for the retrospective measurement of gamma dose using luminescence techniques has been investigated. Bricks of this type are distinguished from fired clay bricks by containing negligible clay and requiring comparatively low temperature treatment during manufacture. They have been used widely in the construction f buildings in the Former Soviet Union since the 1970s but hitherto have not been used for retrospective dosimetry measurements. A procedure based on the se of the 210 deg. C thermoluminescence (TL) peak of quartz was tested with granular quartz extracted from three types of CSB, one of which had been taken from a settlement downwind of Chernobyl. The degree to which the residual geological TL signal within the temperature range of the 210 deg. C L peak had been reduced during manufacture varied with brick type; the levels of residual TL corresponded, in the samples tested, to absorbed ...
2004-02-01
Radon concentrations and absorbed dose measurements in a Pleistocenic cave
International Nuclear Information System (INIS)
Radon concentration measurements were carried out using solid-state nuclear track-etch detectors (SSNTDs) type CA 80-15 cellulose nitrate films, in a Pleistocenic cave at Petralona, in Halkidiki, Northern Greece, at 55 km from the city of Thessaloniki. Radon levels as high as 88 kBqxm"-"3 (2.38 nCi x l"-"1) have been recorded inside the cave equivalent to 11.90 WL in terms of occupational exposure to radon and its decay products. Absorbed dose rates were performed using TL dosimeters, type TLD-200 (CaF_2-Dy) in a continuous monitoring program (integrated measurements). Dose rate levels as high as 110 nGy x h"-"1 were recorded inside the cave. In interpreting the high levels of radiation doses, radioactivity measurements regarding the naturally occurring "2"3"8U, "2"3"2Th and "4"0K radionuclides were carried out in various speleothems found at different sites in the cave. (author)
2003-10-01
Photon dosimetry using plastic scintillators in pulsed radiation fields
Energy Technology Data Exchange (ETDEWEB)
Simulations and experiments have been carried out to explore using a plastic scintillator as a dosimetry probe in the vicinity of a pulsed bremsstrahlung source in the range 4 to 20 MeV. Taking advantage of the tissue-equivalent properties of this detector in conjunction with the use of a fast digital signal processor near real-time dosimetry was shown to be possible. The importance of accounting for a broad energy electron beam in bremsstrahlung production, and photon scattering and build-up, in correctly interpreting dosimetry results at long stand-off distances is highlighted by comparing real world experiments with ideal geometry simulations. Close agreement was found between absorbed energy calculations based upon spectroscopic techniques and calculations based upon signal integration, showing a ratio between 10 MeV absorbed dose to 12 MeV absorbed dose of 0.66 at a distance of ...
2007-04-01
Energy Technology Data Exchange (ETDEWEB)
Methylmethacrylate polymerisation in the presence of 4 wt% butadiene-acrylonitrile rubber was carried out at fixed dose-rate and temperature. The effect of irradiation was investigated with respect to the mechanical and dynamic-mechanical properties in the solid state. A general increase of the 'compatibilisation' on irradiation is obtained. In fact both rubber and polymethylmethacrylate glass transition temperatures, determined through dynamic-mechanical analysis, reveal the presence of strong interactions between the components. Furthermore an improvement of the mechanical tensile properties of the blends is observed when irradiation is continued after polymerisation, at least until a certain absorbed dose.
2001-12-01
The distribution of Lyman-limit absorption systems during and after reionization
Lyman-limit absorption systems can play many important roles during and after cosmological reionization. Unfortunately, due to the prohibitively large dynamic range required, it is impossible to self-consistently include these systems in cosmological simulations. Using fast and versatile semi-numeric simulations, we systematically explore the spatial distribution of absorption systems during and following reionization. We self-calibrate the resulting number of absorbers to the mean free path (mfp) of the ionizing ultraviolet background (UVB), and present results at a given mfp and neutral hydrogen fraction. We use a simple optical depth criterion to identify the locations of absorbers. Our approach is fairly robust to uncertainties such as missing subgrid structure. Unlike at lower redshifts where the UVB is relatively uniform, at higher redshifts the fluctuations in the UVB and the HII morphology of reionization can drive ...
2010-01-01
Calculated fluence spectra at neutron therapy facilities
International Nuclear Information System (INIS)
The Monte Carlo transport codes LAHET and MCNP were used to calculate energy fluence spectra at three neutron therapy facilities. The results compare very favourably with measured data. Kerma spectra and the ratio of ICRU muscle tissue kerma to A-150 kerma, along the carbon to oxygen kerma ratio, were determined. Absorbed dose rate calculations are in reasonable agreement with measured values. Use of these codes to study modifications to existing therapy beams is briefly discussed. (author).
1995-11-13
EFFECT OF ANATOMIC MOTION ON PROTON THERAPY DOSE DISTRIBUTIONS IN PROSTATE CANCER TREATMENT
UK PubMed Central (United Kingdom)
PurposeTo determine the dosimetric impact of inter-fraction anatomical movements in prostate cancer patients receiving proton therapy.Full Text Available
2007-02-01
Retrospective Monte Carlo dose calculations with limited beam weight information
International Nuclear Information System (INIS)
An important unresolved issue in outcomes analysis for lung complications is the effect of poor or completely lacking heterogeneity corrections in previously archived treatment plans. To estimate this effect, we developed a novel method based on Monte Carlo (MC) dose calculations which can be applied retrospectively to RTOG/AAPM-style archived treatment plans (ATP). We applied this method to 218 archived nonsmall cell lung cancer lung treatment plans that were originally calculated either without heterogeneity corrections or with primitive corrections. To retrospectively specify beam weights and wedges, beams were broken into Monte Carlo-generated beamlets, simulated using the VMC++ code, and mathematical optimization was used to match the archived water-based dose distributions. The derived beam weights (and any wedge effects) were then applied to Monte Carlo beamlets regenerated based on the patient computed tomography ...
2007-01-01
International Nuclear Information System (INIS)
Labelling of "1"4C-M-ISP and its absorption, translocation and distribution in peanut and soybean seedling were studied. The results of experiments showed that the radioactive substance could be translocated in xylem and phloem of two kinds of plants. The root of peanut seedling absorbed "1"4C-M-ISP from the nutrient solution more strong than the root of soybean seedling did. After leaf treatment with "1"4C-M-ISP, the soybean seedling absorbed more radioactive substance than peanut seedling did. But the translocation's speed of radioactive substance in pnloem of two kinds of plants were similar.
1990-01-01
The effects of thiamin on lead metabolism: organ distribution of lead 203.
UK PubMed Central (United Kingdom)
The effect of thiamin on the organ distribution of lead was evaluated in CD-1 mice exposed intragastrically or intraperitoneally to a single dose of lead acetate (100 micrograms) containing 100 microCi...Full Text Available
1992-07-01
Radiation risk in diagnostic radiology
International Nuclear Information System (INIS)
An attempt was made to quantify the radiation risk of diagnostic radiology. After a general introduction of terms as radiation damage, radiation risk and effective dose equivalent, based on publications of the ICRP, somatic dose indexes were computed for several radiologic investigations, that comprise organ doses committed to red bone marrow, lung, female breast and thyroid with and without considering the rest of the body. The dose for the rest of the body was assumed to be equal to the dose received by the red bone marrow, that is also distributed over the whole body. Neglecting the exposure of the rest of the body resulted in an insignificant increase in the estimated somatic risk, with its experimental determination not being necessary. (author).
1984-01-01
British Library Electronic Table of Contents (United Kingdom)
Most active pharmaceutical ingredients (API) exhibit particle size distributions with some degrees of asymmetry deviating from log-normality. A new log-skew-normal (L-S-N) distribution model is proposed for a systematic comparison of the asymmetry effect on content uniformity. The new model originated from the S-N model used by Azzalini gives a close approximation to real API particle size distribution. Monte-Carlo method was employed to simulate the dosage potency distribution. A high risk of over potency is uncovered when either the dose is low or API particle size distribution is positively skewed. This is due to the formation of pseudo heavy tail in potency distribution that decays slower than exponentially. Nomographs of API particle size versus dosage strength were constructed with a...
2010-01-01
International Nuclear Information System (INIS)
Natural radioactive materials under certain conditions can reach hazardous radiological levels. The natural radionuclide ("2"3"8U, "2"3"2Th, "4"0K) contents of rock samples at various locations in the North Tushki area were investigated using gamma-spectrometric analysis. Estimates of the measured radionuclide content have been made for the absorbed dose rate of gamma radiation. The equivalent radium (R_e_q) and the external hazard index (H_e_x) which resulted from the natural radionuclides in soil are also calculated and tabulated. The studied samples have been collected from various rock exposures in the North Tushki area. The distribution of major oxides, U and Th were studied. It is found that the enrichment and depletion of the major oxides are mainly due to the effect of hydrothermal alteration, which caused mobility of some major oxides, which increases some elements and decreases others. It is important to mention ...
2002-09-01
Study on dose distribution of therapeutic proton beams with prompt gamma measurement
Energy Technology Data Exchange (ETDEWEB)
The proton beam has an advantage of the sharp dose falloff in dose distribution called Bragg peak while conventional radiation therapy modalities such as photons exhibit considerable amount of exit dose. To take advantage of this property it is important to know the exact location of the distal dose falloff. An error can cause overdose to the normal tissue or underdose to the tumor volume. The only way of finding out the dose distribution in-situ in particle therapy is to measure the gammas produced by nuclear reactions with tissue materials. Two kinds of gammas can be used: one is prompt gamma and the other is coincident gamma from the positron-emission isotopes. We chose to detect prompt gammas, and developed a prompt gamma scanning system (PGS). The proton beams of the proton therapy facility at National Cancer Center were used. The gamma ...
2007-03-15
Radial distribution of dose and cross-sections for the inactivation of dry enzymes and viruses
International Nuclear Information System (INIS)
A new semi-empirical algorithm for the radial distribution of dose is compared with available data. The algorithm is used to calculate the inactivation cross section for dry enzymes and viruses using an extended target model of a 1-hit detector. Agreement with data is at about the 15% level, approximating the precision of the data itself. (author).
1985-05-01
Procedure for radiation dose control in irradiated tissues during electron-beam therapy
International Nuclear Information System (INIS)
The invention refers a procedure of radiation dose control in irradiated tissues during electron-beam therapy. It aims at meeting the planned radiation dose for diseased tissues and taking care of the healthy ones. Therefore, the dose distribution required is determined before irradiation in consideration of such factors as energy-dependence of detector sensitivity, self-absorption within the tissue, and relative biological effectiveness. Furthermore, the expected intensity distribution of secondary quantum radiation excited in the irradiated tissue is calculated. A radiation detector for local resolution is used for registration. During irradiation the calculated intensity distribution is compared with the measured one. The invention is applicable in radiation therapy with monoenergetic electron beams.
1984-11-08
International Nuclear Information System (INIS)
Despite the widely recognized usefulness of the AAPM TG-43 brachytherapy dose calculation formalism, a straightforward application of this approach to describe the dose distribution about intravascular line sources as proposed by TG-60 may be difficult or even impossible, especially when these line sources emit low-energy photons or beta particles. The causes of these limitations are investigated and illustrated by means of some numerical examples. In order to solve the observed limitations an adapted formalism is proposed, intended specifically for the description of the dose rate distribution about line sources but conceptually similar to the TG-43/TG-60 formalism. Several examples are presented to illustrate the usefulness of the proposed line source dose calculation formalism.
2001-04-01
Energy Technology Data Exchange (ETDEWEB)
IMRT with inverse planning allows simultaneous integrated boost strategies that exploit the heterogeneous dose distribution within the planning target volumes (PTVs). In this scenario, the location of cold spots within the target becomes a crucial issue and has to be related to the distribution of the clonogenic cell density (CCD). The main aim of this work is to provide the means to calculate the optimal prescription dose in a relative inhomogeneous dose distribution. To achieve this, the prescription dose has to be assigned to obtain the same tumor control probability (TCP) as the ideal homogeneous distribution, taking into account different CCDs in different PTVs (i.e. visible and subclinical regions). An adapted formulation of the linear-quadratic model, within the F-factor formalism, has been derived to preserve a ...
2008-10-07
This study investigated relationships between molecular weight distributions of unreduced grain proteins and grain, flour, and end-use quality characteristics of soft white winter wheats grown in Oregon. Absorbance area and area % values of protein fractions separated by size exclusion HPLC (SE-HPL...
A doubly Q-switched laser with both an acousto-optic (AO) modulator and a GaAs saturable absorber can obtain a more symmetric and shorter pulse with high pulse peak power, which has been experimentally proved. The key parameters of an optimally coupled doubly Q-switched laser with both an AO modulator and a GaAs saturable absorber are determined, and a group of general curves are generated for what we believe is the first time, when the single-photon absorption (SPA) and two-photon absorption (TPA) processes of GaAs are combined, and the Gaussian spatial distributions of the intracavity photon density and the initial population-inversion density as well as the influence of the AO Q-switch are considered. These key parameters include the optimal normalized coupling parameter, the optimal normalized GaAs saturable absorber parameters, and the normalized parameters of the AO Q-switch, which can maximize ...
2007-08-20
British Library Electronic Table of Contents (United Kingdom)
The homogeneity of a helium dielectric barrier discharge, working at atmospheric pressure and containing oxygen as contaminant, is assessed by mapping the spatial distribution of oxygen metastable atoms in relation to the uniformity of surface properties. Tunable diode laser absorption spectroscopy is used to monitor the time evolution of the absorption coefficient corresponding to the oxygen metastable atoms on the 35S2 level, as a function of the laser absorbing path, whereas bi-dimensional Abel transform is used to obtain local information on the space distribution of the metastable atoms in the discharge. The radial distribution of the surface properties is investigated using atomic force microscopy, contact angle measurement and X-ray photoelectron spectroscopy. The results show that ...
2011-01-01
A study of the distribution of schistosomicidal drug H-3-7505 in mice
Energy Technology Data Exchange (ETDEWEB)
The authors have studied the distribution of H-3 labelled schistosomicidal drug in mice by autoradiography. The H-3-labelled substances were found in liver and kidney and in successfully decreasing amounts in brain, lung, heart, fat, testis, pancreas and spleen. In various cells the silver granules were present mainly in the cytoplasms but a few in the nucleus. After administration of this labelled schistosomicidal drug, the mice were killed and studied in groups successively at 4, 8, 24 hrs. No difference in the distribution of silver granules were observed. This fact indicated that, this drug was rapidly absorbed and highly concentrated with a long duration of reservation in liver. All of these favours the schistosomicidal effect of the drug. As this drug was highly concentrated in the cytoplasm of liver cells, that might provide a pathophysiologic basis for the explanation of jaundice in the clinical practice. Moreover, ...
1985-05-01
Energy Technology Data Exchange (ETDEWEB)
Several short-lived, high-energy beta emitters are being proposed as the radionuclide components for molecular-targeted potential cancer therapeutic agents. The laboratory mice used to determine the efficacy of these new agents have organs that are relatively small compared to the ranges of these high-energy particles. The dosimetry model developed by Hui et al. was extended to provide realistic beta-dose estimates for organs in mice that received therapeutic radiopharmaceuticals containing 90Y, 188Re, 166Ho, 149Pm, 64Cu, and 177 Lu. Major organs in this model included the liver, spleen, kidneys, lungs, heart, stomach, small and large bowel, thyroid, pancreas, bone, marrow, carcass, and a 0.025-g tumor. The study as reported in this paper verifies their results for 90Y and extends them by using their organ geometry factors combined with newly calculated organ self-absorbed fractions from PEREGRINE and MCNP. PEREGRINE and MCNP agree to within 8% ...
2005-08-01
Effect of dose on lead retention and distribution in suckling and adult female mice
Energy Technology Data Exchange (ETDEWEB)
Single doses of lead (trace to 445 mg/kg) were administered per os to suckling and adult mice. Both groups exhibited dose-independent lead retention when doses of 4 to 445 mg/kg were administered. However, developmental differences in the fraction of initial dose (FID) retained were evident for all doses administered. A much larger FID was retained in both age groups following administration of carrier-free /sup 203/Pb. The results are consistent with a mechanism of gastrointestinal lead absorption comprising two or more processes. Developmental differences were also observed in organ lead concentration relative to whole body concentration for kidneys, skull and brain 6 days following lead administration. Lead retentions (relative to whole body retention) in brain and in bone were linearly related to dose of lead administered in both suckling and adult age ...
1980-01-01
TLD array for precise dose measurements in stereotactic radiation techniques
International Nuclear Information System (INIS)
We developed a new TLD array for precise dose measurement and verification of the spatial dose distribution in small radiation targets. It consists of a hemicylindrical, tissue-equivalent rod made of polystyrene with 17 parallel moulds for an exact positioning of each TLD. The spatial resolution of the TLD array was evaluated using the Leskell spherical phantom. Dose planning was performed with KULA 4.4 under stereotactic conditions on axial CT images. In the Leksell gamma unit the TLD array was irradiated with a maximal dose of 10 Gy with an unplugged 14 mm collimator. The doses delivered to the TLDs were rechecked by diode detector and film dosimetry and compared to the computer-generated dose profile. We found excellent agreement of our measured values, even at the critical penumbra decline. For the 14 mm and 18 mm collimator and for the ...
1996-12-01
Bomb "1"4C and human radiation burden
International Nuclear Information System (INIS)
Following the publication (Stenhouse and Baxter, Nature; 267:828 (1977)) of the levels of bomb "1"4C and the residence times of carbon in the human body, excess radiation burdens from this radioisotope are evaluated under the assumption that no radiation dose, however small, can be regarded as entirely harmless biologically. The estimated annual absorbed dose attributable to "1"4C both natural and man-made for 1953-1973 and similar predicted figures for 1975-2025 are shown graphically. The cumulated doses to gonads (over 30 yr) and to bone marrow and bone-lining cells (over 60 yr) and also estimates of the biological damage to reproductive cells from "1"4C #beta#-irradiation (30 yr accumulated dose) are presented. It is concluded from both genetic and somatic considerations, that the potential human radiation burden due to artificially produced "1"4C calculated using the assumptions ...
Study of dose variation in various body parts with respect to chest dose in the working environment
International Nuclear Information System (INIS)
Mixed Uranium Plutonium Carbide ((U, Pu) C), in the form of pellets encapsulated in stainless steel tubes is the fuel for Fast Breeder Test Reactor (FBTR) at Kalpakkam. For the fabrication of fuel for enlarging the core of this reactor, high burn up plutonium is used. The external exposure in these labs was significantly higher than that with low burn up Pu fuel. Dose evaluation to the organs was carried out using experimental TLDs during various operations of FBTR fuel fabrication to study the dose distribution pattern. (author)
2011-02-22
Photon beam modelling with Pinnacle3 Treatment Planning System for a Rokus M Co-60 Machine
International Nuclear Information System (INIS)
The basic relationships of the convolution/superposition dose calculation technique are reviewed, and a modelling technique that can be used for obtaining a satisfactory beam model for a commercially available convolution/superposition-based treatment planning system is described. A fluence energy spectrum for a Co-60 treatment machine obtained from a Monte Carlo simulation was used for modelling the fluence spectrum for a Rokus M machine. In order to achieve this model we measured the depth dose distribution and the dose profiles with a Wellhofer dosimetry system. The primary fluence was iteratively modelled by comparing the computed depth dose curves and beam profiles with the depth dose curves and crossbeam profiles measured in a water phantom. The objective of beam modelling is to build a model of the primary fluence that the patient is exposed to, which can ...
Energy Technology Data Exchange (ETDEWEB)
Faced with increasing indications for the use of iodine-131 labelled lipiodol in the treatment of hepatocellular carcinoma (HCC), it appears essential to develop an individualized dosimetrY so we can predict the potential effectiveness of this treatment and adjust the activity to be injected. We developed a dosimetric protocol based on imagery and dedicated to calculation of the tumoral dose during the treatment of hepatocellular carcinoma by iodine-131 labelled lipiodol. This concept was developed on a SPECT- CT gantry, and integrates corrections for the phenomena of attenuation, diffusion and dead time. The dose is calculated according to the formalism proposed by the Medical Internal Radiation Dose Committee (MIRD). This protocol was applied to a series of 41 patients in the framework of a retrospective study. The results obtained in terms of biodistribution are compatible with previously published data. The total ...
2006-12-15
Glass-heat-pipe evacuated-tube solar collector
A glass heat pipe is adapted for use as a solar energy absorber in an evacuated tube solar collector and for transferring the absorbed solar energy to a working fluid medium or heat sink for storage or practical use. A capillary wick is formed of granular glass particles fused together by heat on the inside surface of the heat pipe with a water glass binder solution to enhance capillary drive distribution of the thermal transfer fluid in the heat pipe throughout the entire inside surface of the evaporator portion of the heat pipe. Selective coatings are used on the heat pipe surface to maximize solar absorption and minimize energy radiation, and the glass wick can alternatively be fabricated with granular particles of black glass or obsidian.
1981-08-06
EPR investigation of some traditional oriental irradiated spices
International Nuclear Information System (INIS)
The 9.50 GHz electron paramagnetic resonance (EPR) spectra of unirradiated and "6"0Co #gamma#-ray irradiated cardamom (Elettaria cardamomum L. Maton, Zingiberaceae), ginger ((Zingiber officinale Rosc., Zingiberaceae), and saffron (Crocus sativus L., Iridaceae) have been investigated at room temperature. All unirradiated spices presented a weak resonance line with g-factors around free-electron ones. After #gamma#-ray irradiation at an absorbed dose of up to 11.3 kGy, the presence of EPR spectra whose amplitude increase monotonously with the absorbed dose has been noticed with all spices. A 100 "oC isothermal annealing of 11.3 kGy irradiated samples has shown a differential reduction of amplitude of various components that compose initial spectra, but even after 3.6 h of thermal treatment, the remaining amplitude represents no less then 30% of the initial ones. The same peculiarities have been noticed ...
2007-06-01
EPR investigation of some irradiated traditional oriental spices
International Nuclear Information System (INIS)
The X-band EPR spectra of unirradiated and "6"0 Co gamma ray irradiated cardamom (Elettaria cardamomum L. Maton, Zingiberaceae), ginger ((Zingiber officinale Rosc., Zingiberaceae), saffron (Crocus sativus L., Iridaceae), and curry have been investigated at room temperature. All unirradiated spices presented a weak resonance line with g-factors around free-electron ones, most probably due to the presence of semiquinones, previously reported to have paramagnetic properties. After gamma ray irradiation at absorbed dose up to 11.3 kGy we have noticed in all spices the presence of complex EPR spectra consisting of a superposition of at last two different paramagnetic species whose amplitude increase monotonously with the absorbed dose. A 100 deg. C isothermal annealing of 11.3 kGy irradiated samples has shown a differential reduction of amplitude of various components that form the initial spectra, but even ...
2005-09-13
Tissue Heterogeneity in IMRT Dose Calculation for Lung Cancer
International Nuclear Information System (INIS)
The aim of this study was to evaluate the differences in accuracy of dose calculation between 3 commonly used algorithms, the Pencil Beam algorithm (PB), the Anisotropic Analytical Algorithm (AAA), and the Collapsed Cone Convolution Superposition (CCCS) for intensity-modulated radiation therapy (IMRT). The 2D dose distributions obtained with the 3 algorithms were compared on each CT slice pixel by pixel, using the MATLAB code (The MathWorks, Natick, MA) and the agreement was assessed with the ? function. The effect of the differences on dose-volume histograms (DVHs), tumor control, and normal tissue complication probability (TCP and NTCP) were also evaluated, and its significance was quantified by using a nonparametric test. In general PB generates regions of over-dosage both in the lung and in the tumor area. These differences are not always in DVH of the lung, although the Wilcoxon test indicated ...
2011-01-01
Principles of protection: a formal approach for evaluating dose distributions
International Nuclear Information System (INIS)
One of the central issues in radiation protection consists in determining what weight should be given to individual doses in relation to collective or aggregated doses. A mathematical framework is introduced in which such assessments can be made precisely in terms of comparisons between alternative distributions of individual doses. In addition to evaluation principles that are well known from radiation protection, a series of principles that are derived from parallel discussions in moral philosophy and welfare economics is investigated. A battery of formal properties is then used to investigate the evaluative principles. The results indicate that one of the new principles, bilinear prioritarianism, may be preferable to current practices, since it satisfies efficiency-related properties better without sacrificing other desirable properties.
2006-03-01
Thermoluminescent (Tl) dosimetry of slow-neutron fields at radiotherapy dose level
Energy Technology Data Exchange (ETDEWEB)
The dosimetry for radiotherapy involving neutrons is very complicated, owing to the complexity of secondary radiation components, whose contributions to the total absorbed dose have to be discriminated, owing to the different radiobiological effects. In order to separate thermal neutrons and photons, LiF dosimeters are mostly utilized. containing different percentage of Li, like as TLD-700, TLD-100 and TLD-600, but many problems arise. In the response of TLD-700 exposed to neutron-gamma mixed fields with high neutron flux, the contribution of thermal neutrons to the Tl emission is high. Moreover. TLD-100 and TLD-600 may undergo radiation damage, and great care has to be taken in order to obtain reliable results. Other TLDs showing lower sensitivity to neutrons are proposed and experimented for such high-flux neutron fields. The faced problems and various proposed solutions are here described. (Author)
2003-07-01
Somatic and genetic radiation exposure of the patient in digital subtraction angiography (DSA)
International Nuclear Information System (INIS)
The somatic and genetic radiation exposure of patients undergoing Digital Subtraction Angiography (DSA) and traditional Film Arteriography (FA) of cranial, cervical, thoracic and abdominal vascular territories are compared. The radiation doses absorbed within the critical organs - red bone marrow, lung, thyroid gland and female breast - and in the gonads were measured using an anthropomorphic Alderson phantom. A Somatic Dose Index was calculated in order to estimate the somatic radiation risk. The somatic radiation exposure depends upon the location of the critical organs with respect to the entrance site of the x-ray beam, and can be reduced by an appropriate choice of the angiographic projection. Under this condition, the radiation exposure of the patient during DSA can be lower than during FA. For renal DSA an a.p. projection, the use of an abdominal compression device and careful caudal shielding of the field are ...
1986-01-01
International Nuclear Information System (INIS)
The MCNPE-BO and MCNP4 Monte Carlo electron-photon codes were used to calculate the dose equivalent per unit fluence at various depths in tissue-equivalent slab phantoms for broad parallel beams of monoenergetic electrons with energies from 50 keV to 10 MeV. The study was carried out in the framework of the activities of a ICRP/ICRU Joint Task Group with the support of EURADOS WG4 (Numerical Dosimetry). Some preliminary results and comparisons as well as a general discussion on the performances of the codes are presented, demonstrating quite a satisfactory agreement among the results obtained using the two codes and those of other authors. (author).
Chemical Analysis of Solid-State Irradiated Human Insulin
British Library Electronic Table of Contents (United Kingdom)
Purpose To study the chemical modifications induced upon irradiation of solid human insulin at radiosterilization doses and investigate the influence of the absorbed dose on radiolysis. Materials and Methods Volatile radiolytic products were monitored by gas chromatography coupled with mass spectrometry (GC-MS) and non-volatile products by two different high performance liquid chromatography (HPLC) methods: the formation of higher molecular weight proteins was assessed by size exclusion liquid chromatography whereas assays for related compounds and chemical potency tests were carried out using reverse-phase HPLC-UV. Conformational changes were investigated by measurements of circular dichroism. Results After gamma irradiation at 10?kGy, the recovery of insulin was 96.8%; higher molecular w...
2006-01-01
A compensating method of an imaging plate response to clinical proton beams
Energy Technology Data Exchange (ETDEWEB)
For charged particle irradiations, the response of an imaging plate (IP) changes around the Bragg peak. Therefore, an appropriate compensation is necessary for the evaluation of dose distribution formed by charged particles such as protons. In this paper, the response of IPs to clinical proton beams is investigated. An experimentally-obtained depth-dose distribution (an ordinary Bragg curve) by a silicon semiconductor detector (SSD) is employed to evaluate the compensation factors as a function of proton penetrating depth, i.e. residual range. A typical dose distribution in a water phantom formed by an L-shaped bolus is measured by IPs and corrected by using the information of those compensation factors; the residual proton range is successfully calculated by the pencil beam algorithm at an arbitrary point. The results show a good agreement with the measurements ...
2002-04-01
International Nuclear Information System (INIS)
Full text: An adaptive response is a decreased biological effect induced by a priming radiation dose given prior to a challenge dose. Adaptive responses contradict the linear-nothreshold model of risk estimation. The pKZ1 mouse chromosomal inversion assay is an extremely sensitive assay for studying the mutagenic effect of low dose radiation. A non-linear dose response for chromosomal inversion has been observed in pKZ1 spleen and prostate after a single whole body irradiation with doses between 1?Gy and 10mGy. Doses between 5-10?Gy resulted in an induction in inversions and doses between 1-10mGy resulted in a reduction below endogenous inversion frequency. These results suggest that doses in the 1-10 mGy range cause host responses which overcompensate by not only preventing inversions that would normally occur as a ...
2006-04-01
IMRT verification by three-dimensional dose reconstruction from portal beam measurements
International Nuclear Information System (INIS)
A method of reconstructing three-dimensional, in vivo dose distributions delivered by intensity-modulated radiotherapy (IMRT) is presented. A proof-of-principle experiment is described where an inverse-planned IMRT treatment is delivered to an anthropomorphic phantom. The exact position of the phantom at the time of treatment is measured by acquiring megavoltage CT data with the treatment beam and a research prototype, flat-panel, electronic portal imaging device. Immediately following CT imaging, the planned IMRT beams are delivered using the multiple-static field technique. The delivered fluence is sampled using the same detector as for the CT data. The signal measured by the portal imaging device is converted to primary fluence using an iterative phantom-scatter estimation technique. This primary fluence is back-projected through the previously acquired megavoltage CT model of the phantom, with inverse attenuation correction, to yield an ...
2002-08-01
Lung dose calculations at kilovoltage x-ray energies using a model-based treatment planning system
International Nuclear Information System (INIS)
The determination of the dose to organs from diagnostic x rays has become important because of reports of radiation injury to patients from fluoroscopically guided interventional procedures. We have modified a convolution/superposition-based treatment planning system to compute the dose distribution for kilovoltage beams. We computed lung doses using this system and compared them to those calculated using the CDI3 organ dose calculation program. We also computed average lung doses from a simulated radiofrequency ablation procedure and compared our results to published doses for a similar procedure. Doses calculated using this system were an average of 20% lower for AP beams and 7% higher for PA beams than those obtained using CDI3. The ratio of the average dose to the lungs to the skin ...
2001-02-01
Estimation of frequency, population doses and stochastic risks in brachytherapy in Japan, 1983
International Nuclear Information System (INIS)
Based on the replies to a questionnaire distributed throughout Japan in 1983, genetically significant dose (GSD), per Caput mean bone marrow dose (CMD), leukemogenically significant dose (LSD), malignantly significant dose (MSD), and per Caput effective dose equivalent (EDE) from using small sealed radiation sources for radiotherapy were estimated. Annual frequencies of brachytherapy were estimated to be 2.6 x 10"3 for men and 36.3 x 10"3 for women, with a total of 38.9 x 10"3. The annual frequencies of using afterloading technique were 0.3 x 10"3 for men and 18.8 x 10"3 for women, with a total of 19.1 x 10"3. The annual population doses per person were 7.9 nGy for GSD, 118 #mu#Gy for CMD, 19.3 #mu#Gy for LSD, 172 #mu#Gy for MSD, and 428 #mu#Gy for EDE. The annual collective effective dose equivalent was estimated to be ...
1988-01-01
The impact of linac output variations on dose distributions in helical tomotherapy
UK PubMed Central (United Kingdom)
It has been suggested for quality assurance purposes that linac output variations for helical tomotherapy (HT) be within ±2% of the long-term average. Due to cancellation of systematic...Full Text Available
2008-01-21
UK PubMed Central (United Kingdom)
PurposeTo assess the prevalence and the dosimetric and clinical predictors of mandibular osteoradionecrosis (ORN) in patients with head and neck (HN) cancer who underwent...Full Text Available
2007-06-01
Recommended ERLs for whole body, thyroid, lung and other single organs are presented in tabular form, and related to the relevant counter measures such as evacuation, sheltering, distribution of stable iodine tablets, etc. Application of ERLs to local env...
1981-01-01
Clinical implementation of a convolution based algorithm for 3D treatment planning
International Nuclear Information System (INIS)
Purpose/Objective: With the advent of computed tomography and magnetic resonance imaging, the three dimensional representation of the patient anatomy has become an invaluable resource for better diagnosis and delineation of the target volume and sensitive structures in radiation therapy. Although the therapeutic linear accelerator industry has made available highly sophisticated equipment, the aggressiveness in dose prescription and delivery has to be complimented by accurate dose computation methods. We have adopted a convolution/superposition algorithm for the calculation of absolute dose that fully accounts for the external shape and internal structure of the patient for photon treatment radiotherapy. In this paper, we will discuss the principles of the convolution algorithm and we will show how the computed dose compares to clinically relevant treatment techniques. Materials and Methods: A computer ...
We present a detailed spectral analysis of point-like X-ray sources in the XMM-COSMOS field. Our sample of 135 sources only includes those that have more than 100 net counts in the 0.3-10 keV energy band and have been identified through optical spectroscopy. The majority of the sources are well described by a simple power-law model with either no absorption (76%) or a significant intrinsic, absorbing column (20%).As expected, the distribution of intrinsic absorbing column densities is markedly different between AGN with or without broad optical emission lines. We find within our sample four Type-2 QSOs candidates (L_X > 10^44 erg/s, N_H > 10^22 cm^-2), with a spectral energy distribution well reproduced by a composite Seyfert-2 spectrum, that demonstrates the strength of the wide field XMM/COSMOS survey to detect these rare and underrepresented sources.
2006-01-01
Accumulation and distribution of "8"5Kr in rats exposed to "8"5Kr atmospheres
International Nuclear Information System (INIS)
Retention kinetics and tissue partition coefficients for "8"5Kr were determined in rats exposed to known concentrations of "8"5Kr gas. The tissue partition coefficients were used to calculate the relative tissue radiation dose, assuming exposure conditions equivalent to the maximum permissible concentration in air (MPC)a. The estimated radiation dose was highest in adrenals and body fat, about twice the dose estimated for the next highest tissue, ovaries. Saturation and desaturation curves show that the contents of the large intestines have a prolonged desaturation time compared to other samples analyzed.
1977-05-01
A dose computation algorithm used in MLC conformal treatment
International Nuclear Information System (INIS)
A dose calculation algorithm for MLC based conformal radiotherapy is described in this paper. The algorithm is formulated by the coordinate of MLC leaves. Verification on the algorithm is made by comparing the dose distributions generated by this algorithm with that generated by a Differential Convolution Superposition algorithm for various regular and irregular fields. The results demonstrate that the present algorithm has suitable accuracy and high computational efficiency, thus it could be useful for the treatment planning process in MLC based conformal radiotherapy, where the workload for interactively or automatically designing the shapes of MLC is heavy. (authors)
2007-12-01
The characterization of electron beam and its importance
International Nuclear Information System (INIS)
The necessity of the electron beam machine characterization via dose measurement is discussed. It includes a measurement of comprehensive dose distribution (at known X and Z axis) for verification of the machine performance. The acquired data were then used to develop the irradiation parameters such as energy, current, distance, conveyor speed, exposure rate and depth inside product to be irradiated. These parameters will be used as a guide for the routine irradiations. (Author)
2003-07-22
Energy Technology Data Exchange (ETDEWEB)
This study evaluates the effect of gamma radiation on the viability of fungi and actinomycetes that contaminate medicinal plants. The relationship between the total lipids of some fungi and actinomycetes and their sensitivity to gamma radiation is also investigated. The data reveal that the viable counts of these florae decrease approximately exponentially with the radiation dose, the effective dose for the elimination of these microorganisms being about 5 kGy for all the medicinal plants under study. Response of pure cultures of fungi and actinomycetes isolated from medicinal plants to increasing absorbed doses of gamma radiation indicate that an increase in radioresistance is in the following order: Streptomyces rimosus, Fusarium solani, Nocardia kuroishii. F. oxysporum, A. fumigatus, A. flavus, A. parasiticus and A. ochraceus. The total lipid contents of molds and actinomycetes have been reported to ...
1997-01-01
Energy Technology Data Exchange (ETDEWEB)
The study compares the doses absorbed by the dentomaxillary area in spiral CT and panoramic examinations. The dose measurements demonstrate that patients receive smaller doses with panoramic radiography than with spiral CT with Dentascan. After following for some variations from instrumental differences, they are in substantial agreement with literature data. Further investigations are needed considering the radiobiological risk related to the growing spread of Dentascan examinations. [Italian] Questo lavoro intende confrontare le dosi assorbite nel distretto dento-mascellare, con le due principali tecniche utilizzate in questo campo: TC spirale e ortopantomografia. Emerge come l'esame panoramico delle arcate dentarie eseguito con l'ortopantomografo comporti la'ssorbimento di dosi inferiori rispetto a quelle dell'esame TC spirale con programma Dentascan. Questi dati, ...
1999-05-01
International Nuclear Information System (INIS)
Dairy products doubly labeled with 45Ca and 47Ca were used to evaluate an extrinsic labeling procedure for calcium bioavailability determination. Nonfat milk, yogurt, and fresh cheese curd were prepared from caprine milk that was intrinsically labeled with 45Ca. The products were then labeled extrinsically with 47Ca and administered to rats by gavage. The 47Ca to 45Ca ratio in bone and teeth averaged about 1.00 with either milk, yogurt, or CaCl2, but the ratio was about 1.04 when dosed with cheese curd. Ca absorption, determined by whole-body counting of 47Ca, was lower (P less than 0.05) in cheese curd (59%) than in either milk (69%), yogurt (72%), or CaCl2 (72%). Expressed as percent of dose, the absorption of 47Ca was highly correlated with bone 47Ca (r = 0.973) and with bone 45Ca (r = 0.946). Correlation between tibia 47Ca and tibia 45Ca was r = 0.923. For the dairy products tested, our results indicated that extrinsic 47Ca was ...
Ultraviolet radiation in Finland
Energy Technology Data Exchange (ETDEWEB)
Solar ultraviolet radiation is damaging for living organisms due to its high energy pro each photon. The UV radiation is often separated into three regions according to the wavelength: UVC (200-280 nm), UVB (280-320 nm) and UVA (320-400 nm). The most hazardous part, UVC is absorbed completely in the upper atmosphere by molecular oxygen. UVB radiation is absorbed by atmospheric ozone partly, and it is reaching Earth`s surface, as UVA radiation. Besides atmospheric ozone, very important factors in determining the intensity of UVB radiation globally are the solar zenith angle and cloudiness. It may be calculated from global ozone changes that the clear-sky UVB doses may have enhanced by 10-15 % during spring and 5-10 % during summer at the latitudes of Finland, following the decrease of total ozone between 1979-90. The Finnish ozone and UV monitoring activities have become a part of international activities, especially the EU ...
1996-12-31
International Nuclear Information System (INIS)
the cotton leaf worm, Spodoptera littoralis (boisd.) were irradiated with 100,150 and 200 Gy to induce inherited sterility. the effects of the tested doses applied to these pupae through three consequent fillial generations and the retarded influence on their F_1,F_2 and F_3 generations progeny were examined . irradiation of parental male induced damage to their daughter females ovaries. the overioles of females among P_1 ,F_1 and F_2 generations showed that the follicular epithelial cells appeared abnormal beside their limited separation from developing oocytes which became shrinked, semi absorbed or completely absorbed leaving vacuoles. the nurse cells were reduced or absent in some parts. damage was obvious through the first and second generations especially at 150 and 200 Gy. in the third generation, ovaries were not greatly affected
2004-02-01
Exact Simulation of Bessel Diffusions
We consider the exact path sampling of the squared Bessel process and some other continuous-time Markov processes, such as the CIR model, constant elasticity of variance diffusion model, and hypergeometric diffusions, which can all be obtained from a squared Bessel process by using a change of variable, time and scale transformation, and/or change of measure. All these diffusions are broadly used in mathematical finance for modelling asset prices, market indices, and interest rates. We show how the probability distributions of a squared Bessel bridge and a squared Bessel process with or without absorption at zero are reduced to randomized gamma distributions. Moreover, for absorbing stochastic processes, we develop a new bridge sampling technique based on conditioning on the first hitting time at zero. Such an approach allows us to simplify simulation schemes. New methods are illustrated with pricing path-dependent options.
2009-01-01
Measurement of dose distributions of linear energy transfer in matter irradiated by fast neutrons
Energy Technology Data Exchange (ETDEWEB)
A detector has been developed and used to measure dose distributions versus linear energy transfer to thin gas targets in spherical geometry from fast neutron irradiation of tissue-equivalent plastic and carbon. The detector is a hemispherical proportional counter with a Cs(T1) scintillator at the center of the hemisphere. The coincidence of the proportional counter signals constrain the measurements to charged particles traversing the radius of the hemisphere. The charged particle energy deposition distributions are directly measured for a known pathlength. The A-150 kerma factor was measured at a neutron energy of 14.8 MeV and is in agreement with tabulated values. The carbon kerma factor measurements are less than the tabulated value at 14.8 MeV. The alpha-particle production in carbon was measured for neutron energies from 14.1 to 14.8 MeV and is compared with existing data.
1990-01-01
Tissue Heterogeneity in IMRT Dose Calculation for Lung Cancer
British Library Electronic Table of Contents (United Kingdom)
The aim of this study was to evaluate the differences in accuracy of dose calculation between 3 commonly used algorithms, the Pencil Beam algorithm (PB), the Anisotropic Analytical Algorithm (AAA), and the Collapsed Cone Convolution Superposition (CCCS) for intensity-modulated radiation therapy (IMRT). The 2D dose distributions obtained with the 3 algorithms were compared on each CT slice pixel by pixel, using the MATLAB code (The MathWorks, Natick, MA) and the agreement was assessed with the gamma function. The effect of the differences on dose-volume histograms (DVHs), tumor control, and normal tissue complication probability (TCP and NTCP) were also evaluated, and its significance was quantified by using a nonparametric test. In general PB generates regions of over-dosage both in the l...
2011-01-01
International Nuclear Information System (INIS)
Background and purpose: The low density of lung tissue causes a reduced attenuation of photons and an increased range of secondary electrons, which is inaccurately predicted by the algorithms incorporated in some commonly available treatment planning systems (TPSs). This study evaluates the differences in dose in normal lung tissue computed using a simple and a more correct algorithm. We also studied the consequences of these differences on the dose-effect relations for radiation-induced lung injury. Materials and methods: The treatment plans of 68 lung cancer patients initially produced in a TPS using a calculation model that incorporates the equivalent-pathlength (EPL) inhomogeneity-correction algorithm, were recalculated in a TPS with the convolution-superposition (CS) algorithm. The higher accuracy of the CS algorithm is well-established. Dose distributions in lung were compared using isodoses, ...
2003-10-01
International Nuclear Information System (INIS)
Full text: Optically stimulated luminescence (OSL) dating of individual sand-sized grains of quartz has advanced significantly over the past decade opening up new vistas in luminescence geochronology. Today, single-grain OSL dating can be used to constrain the burial ages of many deposits, including fluvial sediments, glaciofluvial material and archaeological sediments. It also provides a means of examining the stratigraphic integrity of archaeological sites where sediment mixing might have occurred. An OSL age is calculated by dividing the burial dose (the dose absorbed by the grain since it was last exposed to sunlight) by the environmental dose rate (the rate of supply of ionizing radiation to the grain over the period of burial). To obtain reliable OSL ages, therefore, an accurate estimate of the dose rate is required for each sample. Here we describe our OSL dating campaign at ...
2008-04-13
Energy Technology Data Exchange (ETDEWEB)
Apoptosis is a pattern of cell death involving nuclear pycnosis, cytoplasmic condensation, and karyorrhexis. Apoptosis induced by continuous irradiation with gamma rays (externally given by a 137Cs source) or with beta rays (from tritiated water injected ip) was quantified in the crypts of two portions of mouse bowel, the small intestine and descending colon. The time-course change in the incidence of apoptosis after each type of radiation could be explained on the basis of the innate circadian rhythm of the cells susceptible to apoptotic death and of the excretion of tritiated water (HTO) from the body. For 6-h continuous gamma irradiation at various dose rates (0.6-480 mGy/h) and for 6 h after injection of HTO of various radioactivities (0.15-150 GBq per kg body wt), the relationships between dose and incidence of apoptosis were obtained. Survival curves were then constructed from the curves for dose vs incidence of ...
1989-04-01
International Nuclear Information System (INIS)
Convolution/superposition (C/S) is regarded as the standard dose calculation method in most modern radiotherapy treatment planning systems. Different implementations of C/S could result in significantly different dose distributions. This paper addresses two major implementation issues associated with collapsed cone C/S: one is how to utilize the tabulated kernels instead of analytical parametrizations and the other is how to deal with voxel size effects. Three methods that utilize the tabulated kernels are presented in this paper. These methods differ in the effective kernels used: the differential kernel (DK), the cumulative kernel (CK) or the cumulative-cumulative kernel (CCK). They result in slightly different computation times but significantly different voxel size effects. Both simulated and real multi-resolution dose calculations are presented. For simulation tests, we use arbitrary kernels and ...
2005-02-21
Report of the IPSM working party on low- and medium-energy x-ray dosimetry
Energy Technology Data Exchange (ETDEWEB)
New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).
1991-08-01
Report of the IPSM working party on low- and medium-energy x-ray dosimetry
International Nuclear Information System (INIS)
New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).
1991-01-01
Energy Technology Data Exchange (ETDEWEB)
It was developed a new formulation of macro aggregates of Samarium 153 ({sup 153} Sm-MH) for the arthropaties treatment. The radio pharmaceutic was prepared by reaction of Samarium 153 chloride (SmCl{sub 3}) in aqueous environment with sodium boron hydride in NaOH 0.5 N. The microscopic analysis shown that the particles have an average size of 4% m (range 1-14 {mu} m). The velocity of sedimentation was 0.008 cm/min with high stability in vitro in human serum. The biological studies in healthy rabbits, shown that the complex is retained inside the articulation still eight days after of the administration of the radiopharmaceutical. Likewise, it is presented the data of absorbed dose in the different target organs, which was determined by thermoluminescent dosimetry (TLD) through the use of a REMCAL phantom (radiation equivalent manikin calibration). (Author)
1999-07-01
Irradiation of polyethylene in the presence of antioxidants
International Nuclear Information System (INIS)
The radiation induced reactions in LDPE in the presence of phenolic type antioxidants have been studied. It was shown that various antioxidants can influence the polyethylene network formation and the radical yield in different ways. The dependence of network structure on absorbed doses was determined by gel analysis, hot-set test and extraction of antioxidants for samples irradiated with accelerated electrons. It was found that the antioxidants eluted from polyethylene in higher percentage influence polymer crosslinking to a smaller degree. The ESR studies of #gamma#-irradiated blends of polyethylene with antioxidant indicate the presence of alkyl and phenoxyl radicals. The role of antioxidant molecules on radiation induced reactions in polyethylene-antioxidant systems is considered. The correlation between the network structure and the type of additive in polyethylene is also discussed. (author).
Energy Technology Data Exchange (ETDEWEB)
With the exception of the 1945 Hiroshima and Nagasaki nuclear weapon explosions and the 1986 Tchernobyl reactor accident, most of the radiation accidents concerns the medical and the traditional industrial sectors. The seriousness of the accident is directly function of the absorbed dose. The paper, first, gives the definition of a radiologic accident with its specific criteria and pathological manifestations. Then, some famous historical accidents are reviewed from the discovery of X-rays to recent acute irradiations due to the careless manipulation of radiation sources. From this analysis, three main causes are put forward: the dysfunction of nuclear medicine apparatuses, the victims` lack of training and knowledge of the risks, and the non-identification or the loss of radiation sources. (J.S.). 1 photo.
1996-04-01
CSSX Radiolytic H2 Generation ("Thermolysis") -- Final Report
Energy Technology Data Exchange (ETDEWEB)
The purpose of this work was to determine the radiolytic hydrogen gas yield of irradiated CSSX solvent at several temperatures. The active ingredient of this solvent is calix[4]arene-bis-(t-octylbenzo) crown-6, a calixarene crown ether used for cesium complexation. The solvent also contains 1-(2,2,3,3-tetrafluoropropoxy)-3-(4-sec-butylphenoxy)-2-propanol, a fluorinated alcoholic solvent modifer used to improve the solubility of the calixarene and its cesium complex in the Isopar L diluent. Isopar L is a branch-chain alkane and comprises most of the mixture. Samples of this solution were irradiated to various absorbed ?-ray doses in gas-tight sample containers, which were then sampled for hydrogen gas content. The methods are described below.
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
Perforated thermoplastic masks are used to provide patients immobilization. This procedure inserts a material in the path of the radiation beam, that attenuates and modifies the beam fluence and flatness. The present study evaluates the increase in skin dose as a result of using thermoplastic masks. Relative doses were measured on the surface of a solid water phantom, in the presence and absence of masks. These masks were stretched according to deformation patterns observed in clinical routine. The measurements were obtained with a plane-parallel chamber (Markus type 23343) and radiochromic film (EBT Gafchromic) for 6MV X-rays from a linear accelerator, and for a radiation beam from a cobalt therapy unit. The results showed that thermoplastic masks, whose thickness varied between 2 and 3 mm, increased the dose on the surface by a factor of 3. Due to the variations in the skin dose ...
2010-07-01
AAPM TG-43 formalism for brachytherapy dose calculation of a 137Cs tube source
International Nuclear Information System (INIS)
We present a development of the use of the AAPM TG-43 dose formalism applied to "1"3"7Cs gynecological implant sources. The geometry factor, radial dose function, and anisotropy function of a "1"3"7Cs source modeled after the Nuclear Associates 67-809 series stainless steel jacketed tube source were derived following the AAPM TG-43 formalism. The dose rate distribution through the center of the source using the AAPM TG-43 dose formalism is calculated and compared with the calculations obtained using the Sievert summation and Monte Carlo simulation. The three methods resulted in an agreement within less than 5%, or an isodose rate line agreement within 2 mm. We demonstrate that the AAPM TG-43 formalism can be applied to "1"3"7Cs linear sources and is capable of serving as a "1"3"7Cs dose calculation algorithm that can be used for treatment planning purpose.
2004-04-01
Direct aperture optimization of breast IMRT and the dosimetric impact of respiration motion
International Nuclear Information System (INIS)
We have studied the application of direct aperture optimization (DAO) as an inverse planning tool for breast IMRT. Additionally, we have analysed the impact of respiratory motion on the quality of the delivered dose distribution. From this analysis, we have developed guidelines for balancing the desire for a high-quality optimized plan with the need to create a plan that will not degrade significantly in the presence of respiratory motion. For a DAO optimized breast IMRT plan, the tangential fields incorporate a flash field to cover the range of respiratory motion. The inverse planning algorithm then optimizes the shapes and weights of additional segments that are delivered in combination with the open fields. IMRT plans were generated using DAO with the relative weights of the open segments varied from 0% to 95%. To assess the impact of breathing motion, the dose distribution for the optimized IMRT ...
2006-10-21
Development of Improved Burnable Poisons for Commercial Nuclear Power Reactors
Energy Technology Data Exchange (ETDEWEB)
Burnable poisons are used in nuclear reactors to produce a more level distribution of power in the reactor core and to reduce to necessity for a large control system. An ideal burnable poison would burn at the same rate as the fuel. In this study, separation of neutron-absorbing isotopes was investigated in order to eliminate isotopes that remain as absorbers at the end of fuel life, thus reducing useful fuel life. The isotopes Gd-157, Dy-164, and Er-167 were found to have desirable properties. These isotopes were separated from naturally occurring elements by means of plasma separation to evaluate feasibility and cost. It was found that pure Gd-157 could save approximately $6 million at the end of four years. However, the cost of separation, using the existing facility, made separation cost- ineffective. Using a magnet with three times the field strength is expected to reduce the cost by a factor of ten, making ...
2003-09-30
Is uniform target dose possible in IMRT plans in the head and neck?
International Nuclear Information System (INIS)
Purpose: Various published reports involving intensity-modulated radiotherapy (IMRT) plans developed using automated optimization (inverse planning) have demonstrated highly conformal plans. These reported conformal IMRT plans involve significant target dose inhomogeneity, including both overdosage and underdosage within the target volume. In this study, we demonstrate the development of optimized beamlet IMRT plans that satisfy rigorous dose homogeneity requirements for all target volumes (e.g., #+-#5%), while also sparing the parotids and other normal structures. Methods and Materials: The treatment plans of 15 patients with oropharyngeal cancer who were previously treated with forward-planned multisegmental IMRT were planned again using an automated optimization system developed in-house. The optimization system allows for variable sized beamlets computed using a three-dimensional convolution/superposition dose ...
2002-04-01
Discrepancies in molar extinction coefficients of Fe"3"+ in Fricke dosimetry
International Nuclear Information System (INIS)
Values of the chemical yield, G, and of the molar extinction coefficient, epsilon, for Fricke dosimetry, have been recommended by ICRU. For epsilon, the value in ICRU Reports 17 and 21, 2205 1.mol"-"1.cm"-"1, based on an analysis of 83 reported values. It was suggested that, where neither a careful wavelength calibration nor absorbance linearity checks had been performed, a standard error of 1.5% should be assumed; otherwise 0.15% could be accepted. Alternatively, the accuracy in applying this chemical dose meter was considered improved if there was an independent determination of epsilon with the same spectrophotometer as was used for the determination of the optical density of irradiated Fricke solution. The accuracy claimed for both methods remains questionable, since no complete argumentation could be given for the differences of up to 13% in the published values. Taking into account the discussion of the sources of error by Bryant, ...
1977-12-09
International Nuclear Information System (INIS)
In the early period after the Chernobyl accident, analysis of patterns of "1"3"1I exposure of the human thyroid showed that contaminated milk was the basic source of "1"3"1I intake among the inhabitants of Russia. The equipment and techniques used for measurement of the "1"3"1I content in the thyroids of these individuals are described in this work. A model of the "1"3"1I intake, taking into account protective actions, and a method of thyroid dose calculation are discussed. The mean thyroid dose and frequency distributions of the thyroid doses to inhabitants of towns and villages of the Bryansk, Tula and Orel regions of Russia are presented. The mean dose to the thyroids of children living in the villages was 2 to 5 times higher than the dose to adult thyroids; for children living in the towns, the mean dose was 1.5 to 12 times higher. The ...
Effect of dose on lead retention and distribution in suckling and adult female mice
International Nuclear Information System (INIS)
Single doses of lead (trace to 445 mg/kg) were administered per os to suckling and adult mice. Both groups exhibited dose-independent lead retention when doses of 4 to 445 mg/kg were administered. However, developmental differences in the fraction of initial dose (FID) retained were evident for all doses administered. A much larger FID was retained in both age groups following administration of carrier-free "2"0"3Pb. The results are consistent with a mechanism of gastrointestinal lead absorption comprising two or more processes. Developmental differences were also observed in organ lead concentration relative to whole body concentration for kidneys, skull and brain 6 days following lead administration. Lead retentions (relative to whole body retention) in brain and in bone were linearly related to dose of lead administered in both suckling and adult age groups. ...
Energy Technology Data Exchange (ETDEWEB)
In the case of total skin electron therapy without the beam guide, the electron beam is scattered just outside the gantry exit, dose uniformity in the field is broken, and dose is spread outside the light field. The aims of this study were to measure the mean energy of the off-axis incident electron beam without the beam guide and to establish a reference for the clinical situation. For the measurement, a 4 MeV electron beam was selected among several energies from the linear accelerator. A scintillating fiber beam energy monitor measured the mean energy of the incident electron beam. This energy monitor is a small, light-weight piece of equipment composed of a wedge absorber, scintillation fiber, and photodiode. We found the relationship between electron energy and the indicated value of the energy monitor by means of the estimation of correction factors for five different kinds of electron energy. The preferable linear ...
2002-06-01
Energy Technology Data Exchange (ETDEWEB)
The effect of a complexon therapy scheme including early (in 1 h) administration of Na/sub 3/Ca DTPA and subsequent administration of Na/sub 3/Zn DTPA or Na/sub 3/Ca DTPA at a dose of 25 ..mu..Cimol/kg/day by three 2-week courses (5 times a week) with 2-week interruptions was studied in experiments on 541 male rats after intraperitoneal administration of /sup 239/Pu citrate complex (95 kBq/kg). The treatment resulted in a 3-fold lessening of the content of /sup 239/Pu and absorbed doses in the skeleton, a significant prolongation of the mean survival time (MST) from 452 to 593 days (Na/sub 3/Zn DTPA) and 643 days (Na/sub 3/Ca DTPA), and in a decrease of the osteosarcoma incidence from 76.4 to 32.6-41.2%. The ratio of osteosarcomas per 1 Gy retained in rats (0.076-0.083 %) did not differ from that in untreated animals.
1985-02-01
International Nuclear Information System (INIS)
Current methods to calculate dose distributions with organ motion can be broadly classified as 'dose convolution' and 'fluence convolution' methods. In the former, a static dose distribution is convolved with the probability distribution function (PDF) that characterizes the motion. However, artifacts are produced near the surface and around inhomogeneities because the method assumes shift invariance. Fluence convolution avoids these artifacts by convolving the PDF with the incident fluence instead of the patient dose. In this paper we present an alternative method that improves the accuracy, generality as well as the speed of dose calculation with organ motion. The algorithm starts by sampling an isocenter point from a parametrically defined space curve corresponding to the patient-specific motion trajectory. Then a ...
2005-04-01
Dosimetry for Total Skin Electron Beam Therapy in Skin Cancer
International Nuclear Information System (INIS)
Increasing frequency of skin cancer, mycosis fungoides, Kaposi sarcoma etc, it need to treatment dose planning for total skin electron beam (TSEB) therapy. Appropriate treatment planning for TSEB therapy is needed to give homogeneous dose distribution throughout the entire skin surface. The energy of 6 MeV electron from the 18 MeV medical linear accelerator was adapted for superficial total skin electron beam therapy. The energy of the electron beam was reduced to 4.2 MeV by a 0.5cmx90cmx180cm acryl screen placed in a feet front of the patient. Six dual field beam was adapted for total skin irradiation to encompass the entire body surface from head to toe simultaneously. The patients were treated behind the acryl screen plate acted as a beam scatterer and contained a parallel-plate shallow ion chamber for dosimetry and beam monitoring. During treatment, the patient was placed in six different positions due to be homogeneous ...
1992-06-01
Cytogenetic effects of protracted gamma exposures from conception of male mice
Energy Technology Data Exchange (ETDEWEB)
In order to gain an overall picture of the genetic effects of an increased level of background radiation it is necessary to study the results of protracted exposures to embryonic and immature germ-cell stages as well as to stages found in the mature organism. For this purpose, litters produced by female mice, kept in a 10 or 20 rad/day /sup 60/Co ..gamma..-irradiation field, were kept in the same fields from conception until about 60 days later, having absorbed doses of 526 and 1078 rad respectively. Tests on exposed female offspring showed them to be sterile. Eight weeks after removal from the gamma field, mean testis masses of males in the 20 rad/day series were only half normal but those receiving 10 rad/day were little affected. Frequencies of translocations in spermatocytes at diakinesis/metaphase I were only slightly increased in the exposed series, differences not being significant. Estimated rates of translocation induction were around ...
1982-01-01
Rapid administration of stable iodine is essential for the saturation and subsequent protection of the thyroid gland against the potential harm caused by radioiodines. This paper proposes the Dutch risk analysis that uses an atmospheric dispersion model to calculate the size of the zones around nuclear power plants where radiological thyroid doses for children might be sufficiently high to warrant iodine administration. Dose calculations for possible releases from the nuclear power plants of Borssele (The Netherlands), Doel (Belgium) and Emsland (Germany) are based on two scenarios in combination with a 1-y set of authentic, high-resolution meteorological data. The dimensions of the circular zones were defined for each nuclear power plant. In these zones, with a radius up to 50 km, distribution of stable iodine tablets is advised. PMID:20332130
2010-03-23
Characteristics of the 18 MeV medical linear accelerator 'NELAC-1018', 2. Electron beams
Energy Technology Data Exchange (ETDEWEB)
The performance and characteristics of a medical linear accelerator ''NELAC-1018'' for the electron beam therapy were discussed. Measurement of deep dose distribution revealed that the 80% range was 1.9 cm by 6 MeV, 2.8 cm by 9 MeV, 3.9 cm by 12 MeV, 4.9 cm by 15 MeV and 5.5 cm by 18 MeV. Iso-dose distribution with each tubus and cone showed a favorable flatness by any of the energies. The degree of flatness was extremely favorable, being +-1.7% or less.
1983-11-01
International Nuclear Information System (INIS)
The purpose of this work was to study and quantify the differences in dose distributions computed with some of the newest dose calculation algorithms available in commercial planning systems. The study was done for clinical cases originally calculated with pencil beam convolution (PBC) where large density inhomogeneities were present. Three other dose algorithms were used: a pencil beam like algorithm, the anisotropic analytic algorithm (AAA), a convolution superposition algorithm, collapsed cone convolution (CCC), and a Monte Carlo program, voxel Monte Carlo (VMC++). The dose calculation algorithms were compared under static field irradiations at 6 MV and 15 MV using multileaf collimators and hard wedges where necessary. Five clinical cases were studied: three lung and two breast cases. We found that, in terms of accuracy, the CCC algorithm performed better overall than AAA ...
2007-07-07
International Nuclear Information System (INIS)
The purpose of this work was to study and quantify the differences in dose distributions computed with some of the newest dose calculation algorithms available in commercial planning systems. The study was done for clinical cases where large density inhomogeneities were present. Three dose algorithms were used: a pencil beam like algorithm, the anisotropic analytic algorithm (AAA), a convolution superposition algorithm, collapsed cone convolution (CCC) and a Monte Carlo program, voxel Monte Carlo (VMC++). The dose calculation algorithms were compared under static field irradiations at 6 MV and 15 MV using multileaf collimators and hard wedges where necessary. Five clinical cases were studied: three lung and two breast cases. We found that the CCC algorithm performed overall better than AAA compared to VMC++, but AAA remains an attractive option for routine use in the clinic due to ...
2007-06-01
Evaluation of the increase of superficial dose due to thermoplastic immobilizing in radiotherapy
International Nuclear Information System (INIS)
Perforated thermoplastic masks are used to provide patients immobilization. This procedure inserts a material in the path of the radiation beam, that attenuates and modifies the beam fluence and flatness. The present study evaluates the increase in skin dose as a result of using thermoplastic masks. Relative doses were measured on the surface of a solid water phantom, in the presence and absence of masks. These masks were stretched according to deformation patterns observed in clinical routine. The measurements were obtained with a plane-parallel chamber (Markus type 23343) and radiochromic film (EBT Gafchromic) for 6MV X-rays from a linear accelerator, and for a radiation beam from a cobalt therapy unit. The results showed that thermoplastic masks, whose thickness varied between 2 and 3 mm, increased the dose on the surface by a factor of 3. Due to the variations in the skin dose ...
2010-08-18
Monte Carlo calculations using the codes PENELOPE and GEANT4 have been performed to characterize the dosimetric parameters of the new 20 mm long catheter based $^{32}$P beta source manufactured by Guidant Corporation. The dose distribution along the transverse axis and the two dimensional dose rate table have been calculated. Also, the dose rate at the reference point, the radial dose function and the anisotropy function were evaluated according to the adapted TG-60 formalism for cylindrical sources. PENELOPE and GEANT4 codes were first verified against previous results corresponding to the old 27 mm Guidant $^{32}$P beta source. The dose rate at the reference point for the unsheathed 27 mm source in water was calculated to be $0.215 \\pm 0.001$ cGy s$^{-1}$ mCi$^{-1}$, for PENELOPE, and $0.2312 \\pm 0.0008$ cGy s$^{-1}$ mCi$^{-1}$, for GEANT4. For the ...
2003-01-01
Enhanced spectral discrimination through the exploitation of interface effects in photon dose data
International Nuclear Information System (INIS)
The convolution/superposition algorithm for computing dose from photon beams in radiation therapy planning requires knowledge of the energy spectrum. The algorithm can compute the dose for a polyenergetic beam as the weighted sum of the individual dose contributions from monoenergetic beams. In this study we exploit interface effects apparent in the dose distributions to discriminate among spectra of high energy photon beams. We have studied the sensitivity of the depth dose distribution to the energy components using a hypothetical beam for various field sizes and depths in water and water-lung-water media. Six theoretical spectra were simulated. We compared depth dose data from these spectra using three quantitative measures which are inherently free of normalization ambiguities: for homogeneous water, the ratio ...
2004-02-01
Assessing radiologic risk for population due to human activities
International Nuclear Information System (INIS)
The most important factor in assessing radiologic risk is ensuring scientific means for evaluation of the radioactive release impact upon humans and organisms. To evaluate quantitatively this impact not only knowledge of radioactivity distribution in these dynamical systems is necessary but also understanding the transfer mechanisms between ecosystem components is needed. Thus a complete radioecologic study appear to be very complex and needs defining the source term, dynamic description of radionuclides behavior in the ecosystem, estimation of radiation doses in the major components of the ecosystem and finally the effects of radiation doses upon different parts of the systems. A diagram of the steps implied in evaluation of the effects due to radioactive effluent release in the environment is presented and discussed. The following steps are described: - identification of radioactive sources, as well as their input rate. ...
2002-09-06
Energy Technology Data Exchange (ETDEWEB)
The unsteady two-dimensional laminar flow of a viscous incompressible electrically conducting micro polar fluid via a porous medium past a semi-infinite vertical porous moving plate in the presence of a transverse magnetic field is studied. A uniform magnetic field acts perpendicularly to the porous surface in which absorbs the micro polar fluid with a suction velocity varying with time. The effects of material parameters on the velocity and temperature fields across the boundary layer are investigated. The method of solution can be applied for small perturbation approximation. Numerical results of velocity and temperature distributions of micro polar fluids are compared with the corresponding flow problems for a Newtonian fluid. (author)
2001-07-01
Magnetism and recoilless fraction in metallic glasses after laser irradiation
British Library Electronic Table of Contents (United Kingdom)
Samples of Fe78B13Si9 (Metglas 2605 TCA) and Fe77Cr2B16Si5 (Metglas 2605 S3A) were exposed to pulsed excimer laser irradiation at repetition rates of 15, 25 and 50Hz. The occurrence of out-of-plane magnetic anisotropy, changes in the average hyperfine magnetic field and width of the hyperfine field distribution were evidenced by transmission Mossbauer spectroscopy. The variation of the recoilless fraction with laser processing parameters was derived from the simultaneous recording of Mossbauer spectra using a stainless steel etalon as a dual absorber. Conclusions on the onset of long-range magnetic order were formulated.
2010-01-01
Bragg curve spectroscopy of fission fragments by using parallel plate avalanche counters
Energy Technology Data Exchange (ETDEWEB)
By using a charge-sensitive preamplifier and methods of energy spectroscopy we investigated the response of a parallel plate avalanche counter in order to scan the Bragg curve. The detector was operated in butane, pentane and heptane which also served as stopping gases. In this paper, we report on results obtained with fission fragments from a /sup 252/Cf source. We achieved a separation of the light and heavy fragment groups in the interval of gas absorber thickness from about 500 ..mu..g cm/sup 2/ to 1.5 mg cm/sup 2/. The best energy loss resolution was achieved with pentane at E/papprox.=70 V cm/sup 1/ Torr/sup 1/ resulting in delta..delta..E/..delta..Eapprox.=13%. The corresponding shape of the ..delta..E spectrum reproduces correctly the nuclear charge distribution of the fragments. (orig.).
1985-07-01
BDTPS The BNCT Treatment Planning System jointly developed at DIMNP and JRC/IE
The idea to couple the Treatment Planning System (TPS) to the information on the real boron distribution in the patient is the main added value of the new methodology set-up at DIMNP of University of Pisa, in collaboration with the JRC of Petten (NL). The methodology has been implemented in the new TPS, called BDTPS (Boron Distribution Treatment Planning System), which takes into account the actual boron distribution in the patient brain, while the standard TPS assumes a uniform boron distribution, absolutely far from the reality. Nowadays, Positron Emission Tomography (PET) is able to provide this in vivo information. The new TPS, based on the Monte Carlo technique, has been validated comparing the main BNCT parameters (thermal flux, boron dose, etc.) as measured during the irradiation of a special heterogeneous boron phantom (HEBOM), ad hoc designed, as calculated by the BDTPS and ...
2003-01-01
Interface engineering in chalcopyrite thin film solar devices
Energy Technology Data Exchange (ETDEWEB)
Successful interface engineering requires compositional and electronic material characterization as a prerequisite for understanding and intentionally generating interfaces in photovoltaic devices. The paper gives an overview with several examples, all referring to Cu(In,Ga)(S,Se){sub 2} ('CIGSSe')-based solar cells, with an emphasis on characterization using highly specialized methods, such as elastic recoil detection analysis, X-ray emission spectroscopy and photoelectron spectroscopy using synchrotron and ultraviolet light for excitation, inverse photoemission spectroscopy and Kelvin probe force microscopy. First, the determination of the depth profile of the band gap energy E{sub g} in the absorber layer is demonstrated. The modification of E{sub g} towards both interfaces is discussed in terms of beneficial electronic effects. Next, the interface between absorber and buffer layers with alternative and promising non-toxic ...
2006-06-15
A revised dosimetric model of the adult head and brain
Energy Technology Data Exchange (ETDEWEB)
During the last decade, new radiopharmaceutical have been introduced for brain imaging. The marked differences of these tracers in tissue specificity within the brain and their increasing use for diagnostic studies support the need for a more anthropomorphic model of the human brain and head. Brain and head models developed in the past have been only simplistic representations of this anatomic region. For example, the brain within the phantom of MIRD Pamphlet No. 5 Revised is modeled simply as a single ellipsoid of tissue With no differentiation of its internal structures. To address this need, the MIRD Committee established a Task Group in 1992 to construct a more detailed brain model to include the cerebral cortex, the white matter, the cerebellum, the thalamus, the caudate nucleus, the lentiform nucleus, the cerebral spinal fluid, the lateral ventricles, and the third ventricle. This brain model has been included within a slightly modified version of the head model developed by ...
1996-06-01
A revised dosimetric model of the adult head and brain
International Nuclear Information System (INIS)
During the last decade, new radiopharmaceutical have been introduced for brain imaging. The marked differences of these tracers in tissue specificity within the brain and their increasing use for diagnostic studies support the need for a more anthropomorphic model of the human brain and head. Brain and head models developed in the past have been only simplistic representations of this anatomic region. For example, the brain within the phantom of MIRD Pamphlet No. 5 Revised is modeled simply as a single ellipsoid of tissue With no differentiation of its internal structures. To address this need, the MIRD Committee established a Task Group in 1992 to construct a more detailed brain model to include the cerebral cortex, the white matter, the cerebellum, the thalamus, the caudate nucleus, the lentiform nucleus, the cerebral spinal fluid, the lateral ventricles, and the third ventricle. This brain model has been included within a slightly modified version of the head model developed by ...
1996-07-21
Deterministic calculations of radiation doses from brachytherapy seeds
International Nuclear Information System (INIS)
Brachytherapy is used for treating certain types of cancer by inserting radioactive sources into tumours. CDTN/CNEN is developing brachytherapy seeds to be used mainly in prostate cancer treatment. Dose calculations play a very significant role in the characterization of the developed seeds. The current state-of-the-art of computation dosimetry relies on Monte Carlo methods using, for instance, MCNP codes. However, deterministic calculations have some advantages, as, for example, short computer time to find solutions. This paper presents a software developed to calculate doses in a two-dimensional space surrounding the seed, using a deterministic algorithm. The analysed seeds consist of capsules similar to IMC6711 (OncoSeed), that are commercially available. The exposure rates and absorbed doses are computed using the Sievert integral and the Meisberger third order polynomial, respectively. The software ...
2003-08-17
Analyses of superficial and depth doses in intraoral radiology
Energy Technology Data Exchange (ETDEWEB)
In this work dosimetric analysis using thermoluminescence technique to study the beams characteristics of x-rays employed in dental radiology has been carried out. The obtained results with CaSO{sub 4}:Dy thermoluminescent dosimeters (TLD) were compared to the doses obtained with parallel-plates ionization chamber. Dosimetric evaluations were also done using radiographic films of large dimensions. The x-rays equipments analyzed were installed in the radiological services of Odontology Department of Sergipe Federal University (U.F.S.). Depending on the anatomical region to be examined the proper exposure time was select, for a fix voltage of 70 kV. The results with TLD and ionization chamber have been determined to female and male individuals. The intraoral regions analysed were the peri apical of the incisors, molar and pre-molar teeth and the occlusive region. These regions were simulated using acrylic plates absorbers installed on the film ...
2006-07-01
Optimizing an analytical dose calculation algorithm for fast 2D calculations
International Nuclear Information System (INIS)
Previously, an analytical dose calculation algorithm for MLC-based radiotherapy was developed and commissioned, which includes a detailed model of various MLC effects as a unique feature [1]. The algorithm was originally developed as an independent verification of the treatment planning system's dose calculation and it explicitly modeled spatial and depth dependent MLC effects such as interleaf transmission, the tongue-and-groove effect, rounded leaf ends, MLC scatter, beam hardening, and gradual MLC transmission fall-off with increasing off-axis distance. Originally the algorithm was implemented in Mathematica trademark (Wolfram). To speed up the calculation time and to be able to calculate high resolution 2D dose distributions within a reasonable time frame (<2 s) the algorithm needs to be optimized and to be embedded in a user friendly environment. To achieve this goal, the ...
International Nuclear Information System (INIS)
In the convolution/superposition algorithm, the energy spectrum should be modified to make the reconstructed dose distribution consistent with the measured dose distribution. The energy spectrum, which gives the best agreement, is not determined uniquely depending on the reconstruction procedure. In this report, the effects of the characteristics of the energy spectrum on the calculation accuracy are evaluated by comparing the percentage depth dose (PDD) and beam profiles for the reference energy spectrum with those calculated for the modified spectrum in order to optimize the energy spectrum modification procedure when 4 and 10 MV X-ray beams are used. Decreasing the number of energy bins brought a larger decrease rate in the computation accuracy than a decrease rate in computation time. Further, the decrease of the number of energy bins led to a change of the energy spectrum. The ...
2003-06-01
International Nuclear Information System (INIS)
The model of transient enhanced diffusion of ion-implanted As is formulated and the finite-difference method for numerical solution of the system of equations obtained is developed. The nonuniform distribution of point defects near the interface and more accurate description of arsenic clustering are simultaneously taken into account. Simulation of As diffusion during rapid annealing gives a reasonable agreement with the experimental data. (authors)
2005-09-01
Radial dose distribution of 6.0 MeV/n #alpha#-particle in water
International Nuclear Information System (INIS)
For the study of radiation biology and its application to radiotherapy, the double differential cross section of electron emission from water vapor induced by 6.0 MeV alpha particle beam is measured. The energy spectra of electrons ranging 7- 10000 eV are detected by the electrostatic analyzer and micro channel plate. The measurements are made at angles between 20 and 160 degrees. With use of this data set, the radial dose distribution in water is calculated by using KURBUC code. It is the Monte Carlo type code of the electron transport process, where the track of the electron is simulated through each individual interactions including elastic scattering, ionization cross section and total excitation cross section in case that electrons with certain energy are put in the liquid-density water. In order to understand the effect of radiation when the particle flux is injected in the human body like radiotherapy using accelerator beam, the ...
2003-08-17
International Nuclear Information System (INIS)
In clinical applications, it is very important to accurately determine the range of a proton beam in a patient. Recently, a prototype prompt-gamma scanning system, called a prompt-gamma scanner (PGS), has been constructed at Hanyang University in Korea with the collaboration of the Korean national cancer center (NCC), based on a series of Monte Carlo simulations. The PGS system is composed of a prompt-gamma collimator, a CsI(Tl) scintillation detector, a multi-channel analyzer (MCA), a precision movement system, and an integrated readout system. The prompt-gamma collimator is designed to effectively shield high-energy neutrons from the proton beam passage and subsequent capture gammas. The PGS system can be used to scan the distribution of the prompt gammas in the patient from the proton beam passage. The distribution of the prompt gammas can then be used to determine the proton beam range or the distal dose edge in the ...
2007-09-21
The effect of solutes on defect distributions and hardening in ion-irradiated model ferritic alloys
International Nuclear Information System (INIS)
A series of nine model ferritic alloys were ion irradiated at #propor to#300 C using 2.5 MeV He ions to a dose of 1.4 x 10"2"1 ion/m"2, which corresponds to #propor to#0.1 dpa at a depth of 2 #mu#m and #propor to#3.5 dpa at the peak damage region which occurs at about 4 #mu#m deep. The resultant changes in hardness as a function of depth were measured using a Nanoindenter "t"r"a"d"e"m"a"r"k. TEM was used to investigate the defect distributions. The effect of various solutes, Cu and N in particular, but Mn and Ti as well, on the change of hardness and the defect distribution due to the ion irradiation are discussed. (orig.).
The denoising of Monte Carlo dose distributions using convolution superposition calculations
International Nuclear Information System (INIS)
Monte Carlo (MC) dose calculations can be accurate but are also computationally intensive. In contrast, convolution superposition (CS) offers faster and smoother results but by making approximations. We investigated MC denoising techniques, which use available convolution superposition results and new noise filtering methods to guide and accelerate MC calculations. Two main approaches were developed to combine CS information with MC denoising. In the first approach, the denoising result is iteratively updated by adding the denoised residual difference between the result and the MC image. Multi-scale methods were used (wavelets or contourlets) for denoising the residual. The iterations are initialized by the CS data. In the second approach, we used a frequency splitting technique by quadrature filtering to combine low frequency components derived from MC simulations with high frequency components derived from CS components. The rationale is to take the scattering ...
2007-09-07
An iterative filtered backprojection inverse treatment planning algorithm for tomotherapy
International Nuclear Information System (INIS)
Purpose: An inverse treatment planning algorithm for tomotherapy is described. Methods and Materials: The algorithm iteratively computes a set of nonnegative beam intensity profiles that minimizes the least-squares residual dose defined in the target and selected normal tissue regions of interest. At each iteration the residual dose distribution is transformed into a set of residual beam profiles using an inversion method derived from filtered backprojection image reconstruction theory. These 'residual' profiles are used to correct the current beam profile estimates resulting in new profile estimates. Adaptive filtering is incorporated into the inversion model so that the gross structure of the dose distribution is optimized during initial iterations of the algorithm, and the fine structure corresponding to edges is obtained at later iterations. A three dimensional, kernel based, ...
1995-07-15
Population exposure to power-frequency fields: concepts, components, and control
Energy Technology Data Exchange (ETDEWEB)
There are many sources of population exposures to power-frequency (50/60 Hz) electric and magnetic fields including household appliances and wiring, neighborhood distribution circuits, and high-voltage transmission lines. Bioeffects studies were unable to demonstrate that exposures to power-frequency fields can affect public health. Researcher have likewise been unable to show that the health effects of such exposures are negligible. State and federal regulatory agencies are, therefore, grappling with questions of whether and how to regulate the sitting or design of new extra high-voltage transmission lines so as to control the ground-level fields to which people are exposed. The purpose of this dissertation is to illuminate some of the exposure-related aspects of these question. A taxonomy of the relationship between field encounter and effect is developed to clarify the meaning of terms such as exposure and dose in the power-frequency ...
1986-01-01
Neutron capture therapy beam on the LVR-15 reactor
Energy Technology Data Exchange (ETDEWEB)
Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The distribution of thermal neutrons in the human head phantom was mapped ...
1992-01-01
Neutron capture therapy beam on the LVR-15 reactor
International Nuclear Information System (INIS)
Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The distribution of thermal neutrons in the human head phantom was mapped ...
1991-10-01
International Nuclear Information System (INIS)
Angular distributions of "6Li+"6Li elastic scattering were measured for E_l_a_b=5-40 MeV. An optical model analysis of these data together with older data of "7Li+"7Li elastic scattering taken at E_l_a_b = 8-17 MeV was performed with the aim to search for a ''global'' OM potential which describes elastic scattering in both Li-Li systems in a broad energy range. Both surface and volume absorbing potentials can be found which fulfill this requirement if a linear energy dependence is assumed of the depths of the real as well as the imaginary potential. These depths, if fitted to individual angular distributions, are found to vary in a correlated manner with the beam energy. This is taken as indication of strong coupling between elastic, inelastic, and reaction channels. This is corroborated by the existence of resonances in reaction channels at these energies where the potential depths are most pronouncedly changing. (orig.).
International Nuclear Information System (INIS)
Full text: A semiempirical algorithm for absorbed dose calculation at off-axis points in irregular beams was implemented. It is well known that semiempirical methods are very useful because of their easy implementation and its helpfulness in dose calculation in the clinic. These methods can be used as independent tools for dosimetric calculation in many applications of quality assurance. However, the applicability of such methods has some limitations, even in homogeneous media, specially at off axis points, near beam fringes or outside the beam. Only methods derived from tissue-air-ratio (TAR) or scatter-maximum-ratio (SMR) have been devised for those situations, many years ago. Despite there have been improvements for these manual methods, like the Sc-Sp ones, no attempt has been made to extend their usage at off axis points. In this work, a semiempirical formalism was introduced, based on the works of Venselaar et al. ...
2008-10-19
International Nuclear Information System (INIS)
Brachytherapy refers to short distance treatment of cancer with radiation from small, encapsulated radionuclide sources. This type of treatment is given by placing sources directly into or near the volume to be treated. The dose is then delivered continuously, either over a short period of time (temporary implants) or over the lifetime of the source to a complete decay (permanent implants). This technique is extensively used in the treatments of gynecological, breast, prostate, head and neck, and other soft tissue cancers. The clinical outcomes of this treatment depend on accurate dosimetry and dose delivery. The patient is generally considered to be water equivalent. So the treatment planning system software generally is based on measured or calculated dose distributions in homogenous water medium. In real situation, the treatment volume is not homogenous water medium, but it is a heterogeneous medium ...
2009-04-01
International Nuclear Information System (INIS)
The distribution of radiation dose commitments within the body that can result from the lung deposition of a number of transuranic radionuclides ("2"3"7Pu, "2"3"8Pu, "2"3"9Pu, "2"4"0Pu, "2"4"1Pu, "2"4"2Pu, "2"4"3Pu, "2"4"4Pu, "2"4"1Am, "2"4"2Am, "2"4"3Am, "2"4"4Am, "2"4"2Cm, "2"4"3Cm, "2"4"4Cm, and "2"4"6Cm) was calculated. The variables that influence these organ dose commitments include the mobility of the particle or its dissolution products within the body, the radiation characteristics of the inhaled radionuclides and their progeny, and the size of the particles inhaled. In the calculation of organ dose commitments for whole-body, lungs, liver, bone tissues, kidneys, and gastrointestinal tract from the inhalation of transuranium radionuclides, physical characteristics of importance are the dimensions of the particle, its aerodynamic properties, and its density. For particles within the respirable ...
1975-11-17
Synthesis and PET imaging of the benzodiazepine receptor tracer [N-methyl-"1"1C]iomazenil
International Nuclear Information System (INIS)
The central benzodiazepine receptor tracer [N-methyl-"1"1C]iomazenil (Ro 16-0154) was synthesized by alkylation of the desmethyl precursor noriomazenil with ["1"1C]methyl iodide. The ["1"1C]CH_3I (prepared by reduction of ["1"1C]CO_2 with LiAlH_4 followed by reaction with HI) was reacted with noriomazenil inN,N -dimethylformamide and Bu_4N"+OH"- for 1 min at 80 deg. C and purified by HPLC (C_1_8, 34% CH_3CN/H_2O, 7 mL/min). The product was obtained with synthesis time 35 #+-# 5 min (mean #+-# SD, n = 7), radiochemical yield (EOB) 36 #+-# 16%, radiochemical purity 99 #+-# 1%, and specific activity 5100 #+-# 2800 mCi/#mu#mol. Absorbed radiation doses were calculated from previously acquired human biodistribution data. The urinary bladder wall received the highest dose (0.099 mGy/MBq) for 4.8 h voiding interval and the effective dose equivalent was 0.015 mSv/MBq. After i.v. injection of ["1"1C]iomazenil in ...
1995-07-01
Energy Technology Data Exchange (ETDEWEB)
Molybdenum is an essential element for living organisms. Moreover its radionuclides may represent an incorporation risk for members of the public and/or radiation workers after a nuclear accident or a release of radioactive materials. However, only few reliable data on Mo biokinetics in humans were available. The results of recent tracer kinetic investigations with stable isotopes have shown several differences from the ICRP data with regard to the processes of intestinal absorption and of excretion. As a consequence, the dose coefficients calculated with a revised biokinetic model deviate from the ICRP estimates. By ingestion of {sup 99}Mo radionuclides with solid food, for example, the dose to the colon may be higher of a factor up to 1 order of magnitude, due to the fraction of non-absorbed material which traverses the gastro-intestinal tract. (orig.) [Deutsch] Molybdaen ist einerseits ein fuer Lebewesen essentielles ...
1998-12-31
Energy Technology Data Exchange (ETDEWEB)
Hepatocellular carcinoma (HCC) is the most common primary liver cancer and has very limited therapeutic options. Recently, it has been found that hyaluronic acid (HA) shows selective binding to CD44 receptors expressed in most cancer histotypes. Since the trend in cancer treatment is the use of targeted radionuclide therapy, the aim of this research was to label HA with rhenium-188 and to evaluate its potential use as a hepatocarcinoma therapeutic radiopharmaceutical. Methods: {sup 188}Re-HA was prepared by a direct labelling method to produce a ReO(O-COO){sub 2}-type coordination complex. {sup 188}Re-HA protein binding and its stability in saline, phosphate buffer, human serum and cysteine solutions were determined. Biokinetic and dosimetric data were estimated in healthy mice (n=60) using the Medical Internal Radiation Dose methodology and mouse model beta-absorbed fractions. To evaluate liver toxicity, alanine aminotranferase (AST) and ...
2009-08-15
Antimicrobials in the Management of Post-Irradiation Infection
... develops. An alternative approach is the use of non-absorbable antibiot- ics such as polymyxin, neomycin, and bacitracin. ...
2011-05-13
International Nuclear Information System (INIS)
The Seismic Proving Test of Heavy Component with Energy Absorbing Supports has been conducted to prove the reliability of advanced seismic technology, supporting heavy component such as PWR steam generator with large capacity energy absorbing supports under the sponsorship of Ministry of Economical Trade and Industry. If energy absorbing supports are adopted for NPP heavy components, support structure of facility will be much simplified due to their seismic energy absorbing effect. The paper describes the results of lead damper element test and seismic test at Tadotsu Laboratory, using 1/2.5 scale PWR Steam Generator model supported by Lead Extraction Damper (LED) and development of characteristics evaluation formula of energy absorbing support. (author)
2003-09-15
Radiation-induced reduction of ditetrazolium salt in aqueous solutions
Energy Technology Data Exchange (ETDEWEB)
Color formation in aqueous solutions of the ditetrazolium salt blue tetrazolium (BT{sup 2+}) in the absence or presence of oxygen is a complex radiation chemical reaction. The final stable product is the poorly soluble diformazan violet to blue pigment having a broad spectral absorption band ({lambda}{sub max}=552 nm). The reaction of BT{sup 2+} with the hydrated electron proceeds by rapid reduction of BT{sup 2+} followed by protonation at the nitrogen closest to the unsubstituted phenyl group, via the two intermediate tetrazolinyl radicals shared by the ditetrazole ring nitrogens. The effect of solution pH, N{sub 2}O saturation, and the presence of the reducing agent dextrose are examined. The system serves as a radiochromic sensor and a dosimeter of ionizing radiations. Solutions of 5 mmol l{sup -1} BT{sup 2+} at pH 7.3 serve as dosimeters over an absorbed-dose range of approximately 0.2-6 kGy (dearated, with a range of 1-8 mmol l{sup -1} dextrose) and of about ...
2002-04-01
ESR/Alanine dosimetry on Wolsung Unit 1
Energy Technology Data Exchange (ETDEWEB)
Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement result shows extremely high radiation level ...
2007-07-01
ESR/Alanine dosimetry on Wolsung Unit 1
International Nuclear Information System (INIS)
Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement result shows extremely high radiation level ...
2007-05-10
Bioavailability of lead in rats fed human diets
International Nuclear Information System (INIS)
The bioavailability of lead was studied in rats fed various baby foods (Babymix-turkey, Babymix-vegetables, Frutolino-fruit, Frutamix-bananas, Babyron-S-26, Truefood), cow's milk, bread, liver and standard rat diet. Lead absorption was determined by measuring the whole body retention of "2"0"3Pb 6 days after a single oral application. Highest absorption values ranging from 17 to 20% were obtained in animals fed cow's milk and fruit foods. Rats on other human diets absorbed between 3 and 8% of the radioactive lead dose. Only in animals on rat diet lead absorption was below 1%. It is concluded that rats fed human diets show absorption values similar to those in humans. This might indicate that the bioavailability of lead is primarily dependent on dietary habits. This experimental model, if confirmed by further work, might be useful for obtaining preliminary data on the bioavailability of metals from various foods.
Energy Technology Data Exchange (ETDEWEB)
In radiation therapy with hadron beams, conformal irradiation to a tumour can be achieved by using the properties of incident ions such as the high dose concentration around the Bragg peak. For the effective utilization of such properties, it is necessary to evaluate the volume irradiated with hadron beams and the deposited dose distribution in a patient's body. Several methods have been proposed for this purpose, one of which uses the positron emitters generated through fragmentation reactions between incident ions and target nuclei. In the previous paper, we showed that the maximum likelihood estimation (MLE) method could be applicable to the estimation of beam end-point from the measured positron emitting activity distribution for mono-energetic beam irradiations. In a practical treatment, a spread-out Bragg peak (SOBP) beam is used to achieve a uniform biological dose ...
2005-12-21
Therapeutic Applications of Monte Carlo Calculations in Nuclear Medicine
This book examines the applications of Monte Carlo (MC) calculations in therapeutic nuclear medicine, from basic principles to computer implementations of software packages and their applications in radiation dosimetry and treatment planning. It is written for nuclear medicine physicists and physicians as well as radiation oncologists, and can serve as a supplementary text for medical imaging, radiation dosimetry and nuclear engineering graduate courses in science, medical and engineering faculties. With chapters is written by recognised authorities in that particular field, the book covers the entire range of MC applications in therapeutic medical and health physics, from its use in imaging prior to therapy to dose distribution modelling targeted radiotherapy. The contributions discuss the fundamental concepts of radiation dosimetry, radiobiological aspects of targeted radionuclide therapy and the various components and steps required for ...
2003-01-01
British Library Electronic Table of Contents (United Kingdom)
Rapid administration of stable iodine is essential for the saturation and subsequent protection of the thyroid gland against the potential harm caused by radioiodines. This paper proposes the Dutch risk analysis that uses an atmospheric dispersion model to calculate the size of the zones around nuclear power plants where radiological thyroid doses for children might be sufficiently high to warrant iodine administration. Dose calculations for possible releases from the nuclear power plants of Borssele (The Netherlands), Doel (Belgium) and Emsland (Germany) are based on two scenarios in combination with a 1-y set of authentic, high-resolution meteorological data. The dimensions of the circular zones were defined for each nuclear power plant. In these zones, with a radius up to 50 km, distrib...
2010-01-01
Monte Carlo calculations using the codes PENELOPE and GEANT4 have been performed to characterize the dosimetric properties of monoenergetic photon point sources in water. The dose rate in water has been calculated for energies of interest in brachytherapy, ranging between 10 keV and 2 MeV. A comparison of the results obtained using the two codes with the available data calculated with other Monte Carlo codes is carried out. A chi2-like statistical test is proposed for these comparisons. PENELOPE and GEANT4 show a reasonable agreement for all energies analyzed and distances to the source larger than 1 cm. Significant differences are found at distances from the source up to 1 cm. A similar situation occurs between PENELOPE and EGS4.
2006-01-01
Enhancement of Heat and Mass Transfer in Mechanically Contstrained Ultra Thin Films
Energy Technology Data Exchange (ETDEWEB)
Oregon State University (OSU) and the Pacific Northwest National Laboratory (PNNL) were funded by the U.S. Department of Energy to conduct research focused on resolving the key technical issues that limited the deployment of efficient and extremely compact microtechnology based heat actuated absorption heat pumps and gas absorbers. Success in demonstrating these technologies will reduce the main barriers to the deployment of a technology that can significantly reduce energy consumption in the building, automotive and industrial sectors while providing a technology that can improve our ability to sequester CO{sub 2}. The proposed research cost $939,477. $539,477 of the proposed amount funded research conducted at OSU while the balance ($400,000) was used at PNNL. The project lasted 42 months and started in April 2001. Recent developments at the Pacific Northwest National Laboratory and Oregon State University suggest that the performance of absorption and desorption ...
2005-01-01
Energy Technology Data Exchange (ETDEWEB)
It is planned to use the tritium dose model, DCART (Doses from Chronic Atmospheric Releases of Tritium), to reconstruct dose to the hypothetical maximally exposed individual from annual routine releases of tritiated water (HTO) and tritiated hydrogen gas (HT) from all Lawrence Livermore National Laboratory (LLNL) facilities and from the Sandia National (SNL) Laboratory's Tritium Research Laboratory over the last fifty years. DCART has been described in Part 1 of ''Historical Doses From Tritiated Water And Tritiated Hydrogen Gas Released To The Atmosphere from Lawrence Livermore National Laboratory (LLNL)'' (UCRL-TR-205083). This report (Part 2) summarizes information about annual routine releases of tritium from LLNL (and SNL) since 1953. Historical records were used to derive facility-specific annual data (e.g., source terms, dilution factors, ambient air ...
2005-03-07
Growth and cell kinetic changes of HeLa S-3 spheroids following hyperfractionated irradiation
International Nuclear Information System (INIS)
Optimal design of the hyperfractionated radiotherapy requires basic radiobiological data such as the critical dose per fraction, number of fractions per day and total equivalent dose, to name a few. As a prelude to in vivo hyperfractionated irradiation, the authors carried out experiments to determine quantitative changes in the proliferation and cell kinetic parameters of multicellular spheroids after hyperfractionated irradiation. Experiments were carried out with HeLa S-3 spheroid growing in MEM culture media. Hyperfractionated irradiation schedules were 1.5 Gy/f, 2f/day and 1.0 Gy/f, 3 f/day. At intervals after irradiation, cell numbers, growth delays and cell cycle distribution of spheroids were determined. The kinetic data were obtained by the use of flow cytometry. The most pronounced changes in cell kinetic parameters were early G/sub 2/M block, proportional to single radiation dose up to 4.0 ...
International Nuclear Information System (INIS)
Purpose: In this paper, we present an alternative to the originally proposed technique for the delivery of spatially fractionated radiation therapy (GRID) using multi-leaf collimator (MLC) shaped fields. We employ the MLC to deliver various pattern GRID treatments to large solid tumors and dosimetrically characterize the GRID fields. Methods and materials: The GRID fields were created with different open to blocked area ratios and with variable separation between the openings using a MLC. GRID designs were introduced into the Pinnacle"3 treatment planning system, and the dose was calculated in a water phantom. Ionization chamber and film measurements using both Kodak EDR2 and Gafchromic EBT film were performed in a SolidWater phantom to determine the relative output of each GRID design as well as its spatial dosimetric characteristics. Results: Agreement within 5.0% was observed between the Pinnacle"3 predicted dose ...
2009-10-01
Depleted uranium human health risk assessment, Jefferson Proving Ground, Indiana
Energy Technology Data Exchange (ETDEWEB)
The risk to human health from fragments of depleted uranium (DU) at Jefferson Proving Ground (JPG) was estimated using two types of ecosystem pathway models. A steady-state, model of the JPG area was developed to examine the effects of DU in soils, water, and vegetation on deer that were hunted and consumed by humans. The RESRAD code was also used to estimate the effects of farming the impact area and consuming the products derived from the farm. The steady-state model showed that minimal doses to humans are expected from consumption of deer that inhabit the impact area. Median values for doses to humans range from about 1 mrem ({plus_minus}2.4) to 0.04 mrem ({plus_minus}0.13) and translate to less than 1 {times} 10{sup {minus}6} detriments (excess cancers) in the population. Monte Carlo simulation of the steady-state model was used to derive the probability distributions from which the median values were drawn. Sensitivity ...
1994-04-29
FFTF reactor characterization program
International Nuclear Information System (INIS)
Preparations are under way for the initial startup and testing of the Fast Flux Test Facility (FFTF). The FFTF Reactor Characterization Program is that part of the startup test plan that deals with the determination of the neutron, gamma ray and thermal hydraulic characteristics of the reactor. This program encompasses measurements and calculations of: neutron spectra, flux and fluence; gamma-ray spectra, dose and heating; fission rate distributions; capture rate distributions; other reaction rates of interest; fission product yields; and thermal hydraulic data. Measurements of these parameters will be made in the reactor core and reflectors, will extend vertically downward to the vicinity of the core support structure and upward to the top of the sodium pool, and will extend radially outward to include in-vessel fuel storage locations and the cavity between the reactor vessel and the concrete wall.
International Nuclear Information System (INIS)
The dithiocarbamate and thiuram compounds, including disulfiram, were compared for their efficacies in influencing tissue distribution of a trace dose of intravenously injected lead plus "2"0"3Pb in rats. The tested compounds were sodium diethyldithiocarbamate (DEDTC), sodium dimethyldithiocarbamate (DMDTC), tetraethylthiuram disulfide (disulfiram), a complex of zinc and manganese ethylenebisdithiocarbamate (mancozeb), manganese ethylenebisdithiocarbamate (maneb), sodium monomethyldithiocarbamate (metham), zinc propylene bisdithiocarbamate (propineb), tetramethylthiuram disulfide (thiram), zinc ethylenebisdithiocarbamate (zineb), and zinc dimethyldithiocarbamate (ziram). The results of this study show that interactions can occur between lead and DEDTC, DMDTC, disulfiram, metham, thiram, and ziram, resulting in increased levels of lead in brain and probably potentiation of the neurotoxic effects of lead.
International Nuclear Information System (INIS)
A study on the distribution of "1"3"7Cs in coastal waters up to a distance of 15 km was undertaken for a decade (1995-2004) and observed that the activity has reduced by 15-20 fold. Statistical and trend analysis was carried out to resolve the contribution of different facilities at a distance of 5 km (north and south) from the discharge point by log normal probability analysis and found that at 5 km south, the median value of "1"3"7Cs due to TAPS and FRP discharges were 3.7 mBq/l and 1.50 mBq/l respectively. The observed levels of "1"3"7Cs are of no consequences from the point of view of dose to members of the public. (author)
2005-11-23
Is energy imparted a good measure of the radiation risk associated with CT examinations
International Nuclear Information System (INIS)
The dose distribution in a Rando phantom has been measured for typical EMI 5005 CT scans of the head, chest, abdomen and pelvis. These dose distributions have been used to generate quantitative estimates of the somatic and genetic radiation risks associated with these CT examinations and also to measure the total energy imparted during each scan. A comparison has been made between the radiation risk estimates and the energy imparted measurements. The energy imparted measurements are not a good indicator of the somatic and/or genetic risks when one type of CT scan is compared with another. However, for a given type of scan, the energy imparted may be a reasonable indicator of the relative somatic risks associated with different CT examinations. Considerable care should be taken when interpreting and using any measured value of energy imparted in a radiological examination since published values of the ...
Characterization of an add-on multileaf collimator for electron beam therapy
Energy Technology Data Exchange (ETDEWEB)
An add-on multileaf collimator for electrons (eMLC) has been developed that provides computer-controlled beam collimation and isocentric dose delivery. The design parameters result from the design study by Gauer et al (2006 Phys. Med. Biol. 51 5987-6003) and were configured such that a compact and light-weight eMLC with motorized leaves can be industrially manufactured and stably mounted on a conventional linear accelerator. In the present study, the efficiency of an initial computer-controlled prototype was examined according to the design goals and the performance of energy- and intensity-modulated treatment techniques. This study concentrates on the attachment and gantry stability as well as the dosimetric characteristics of central-axis and off-axis dose, field size dependence, collimator scatter, field abutment, radiation leakage and the setting of the accelerator jaws. To provide isocentric irradiation, the eMLC can be placed either 16 or ...
2008-02-21
International Nuclear Information System (INIS)
The main problems arising in decommissioning nuclear-powered submarines (NPS) relate to choosing a concept of handling reactor compartments followed by handling technology development. Reactor compartments (RC) are characterized with extremely space-saving or integral layout of large-size power equipment and systems, restricted access for dismantling, high radiation dose rates in a number of bays of RC. The above RC features pose a problem to find optimum option of RC utilization which on the one hand would be the most cost efficient, and the safest as possible on the other, i.e. dose commitments of personnel involved should be minimum, and effect on population and environment should be negligible. The main radiation factors specifying safety in RC handling at any decommissioning stage are as follows: (1) total radioactivity integrated in reactor facility (RF); (2) distribution of this radioactivity through RF equipment and ...
1996-03-10
Energy Technology Data Exchange (ETDEWEB)
The influence of high energy electron (23 MeV) irradiation on the electrical characteristics of p-channel polysilicon thin film transistors (PSTFTs) was studied. The channel 220 nm thick LPCVD (low pressure chemical vapor deposition) deposited polysilicon layer was phosphorus doped by ion implantation. A 45 nm thick, thermally grown, SiO{sub 2} layer served as gate dielectric. A self-alignment technology for boron doping of the source and drain regions was used. 200 nm thick polysilicon film was deposited as a gate electrode. The obtained p-channel PSTFTs were irradiated with different high energy electron doses. Leakage currents through the gate oxide and transfer characteristics of the transistors were measured. A software model describing the field enhancement and the non-uniform current distribution at textured polysilicon/oxide interface was developed. In order to assess the irradiation-stimulated changes of gate oxide parameters the gate ...
2006-08-15
International Nuclear Information System (INIS)
The influence of high energy electron (23 MeV) irradiation on the electrical characteristics of p-channel polysilicon thin film transistors (PSTFTs) was studied. The channel 220 nm thick LPCVD (low pressure chemical vapor deposition) deposited polysilicon layer was phosphorus doped by ion implantation. A 45 nm thick, thermally grown, SiO_2 layer served as gate dielectric. A self-alignment technology for boron doping of the source and drain regions was used. 200 nm thick polysilicon film was deposited as a gate electrode. The obtained p-channel PSTFTs were irradiated with different high energy electron doses. Leakage currents through the gate oxide and transfer characteristics of the transistors were measured. A software model describing the field enhancement and the non-uniform current distribution at textured polysilicon/oxide interface was developed. In order to assess the irradiation-stimulated changes of gate oxide parameters the gate oxide ...
2006-08-01
Dose, exposure time, and resolution in Serial X-ray Crystallography
The resolution of X-ray diffraction microscopy is limited by the maximum dose that can be delivered prior to sample damage. In the proposed Serial Crystallography method, the damage problem is addressed by distributing the total dose over many identical hydrated macromolecules running continuously in a single-file train across a continuous X-ray beam, and resolution is then limited only by the available molecular and X-ray fluxes and molecular alignment. Orientation of the diffracting molecules is achieved by laser alignment. We evaluate the incident X-ray fluence (energy/area) required to obtain a given resolution from (1) an analytical model, giving the count rate at the maximum scattering angle for a model protein, (2) explicit simulation of diffraction patterns for a GroEL-GroES protein complex, and (3) the frequency cut off of the transfer function following iterative solution of the phase problem, and reconstruction ...
2007-01-01
An evaluation of the pendulum technique of electron beam therapy
International Nuclear Information System (INIS)
Electron beam therapy of lesions such as cutaneous metastatic carcinoma and reticulum cell sarcoma is performed via multiple portals for a wide irradiation field. However, the dose distribution in border areas is generally uneven, resulting in hot and cold dose areas depending on the intervals of the portals. We performed electron irradiation by the pendulum technique, especially on curved areas, and evaluated the technique in various respects. Pendulum electron beam irradiation is indicated when the length of the cone must be reduced in order to deliver the target volume near the skin surface as well as to avoid the occurrence of hot spots deep in the body. We prepared a 15cm rotating cone by cutting a 30cm fixed irradiation cone. The modification posed no disadvantages in terms of extent and flatness of the beam, or stability during rotation. After determining the relationship between the rotation speed and the ...
Synthesis and tissue distribution study of iodine-labeled benzyl- and xylylamines
Energy Technology Data Exchange (ETDEWEB)
Four /sup 125/I labeled mono- and diamines were prepared and evaluated as potential brain-imaging agents. The diamines are analogues of the previously reported /sup 75/Se labeled diamines, which show high brain uptake and retention. All of the radioiodinated amines display high initial brain uptake in rats after intravenous injection (1.7-2.4% dose/organ). The xylylenediamines show prolonged brain retention (t1/2 approximately 18 h), which is desirable for brain imaging. In contrast, the benzylamine is rapidly cleared from brain tissue (t1/2 approximately 15 min).
1982-07-01
Energy Technology Data Exchange (ETDEWEB)
The bibliography contains citations concerning plasma immersion ion implantation (PIII) and equipment. PIII is a new technique to implant plasma ions into materials for surface modification and treatment. Topics include plasma nitriding, semiconductor doping, ion energy distribution, ion dose, pulsed plasma, metal plasma, and defect passivation. References also review applications in semiconductor device and integrated circuit manufacture, silicon material fabrication, aerospace bearings, carbon coatings on metals, and ceramic coatings. (Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)
1998-01-01
The Development of 6061-Aluminum Windows for the MICE LiquidAbsorber
Energy Technology Data Exchange (ETDEWEB)
The thin windows for the Muon Ionization Cooling Experiment (MICE) liquid Absorber will be fabricated from 6061-T6-aluminum. The absorber and vacuum vessel thin windows are 300-mm in diameter and are 180 mm thick at the center. The windows are designed for an internal burst pressure of 0.68 MPa (100 psig) when warm. The MICE experiment design calls for changeable windows on the absorber, so a bolted window design was adopted. Welded windows offer some potential advantages over bolted windows when they are on the absorber itself. This report describes the bolted window and its seal. This report also describes an alternate window that is welded directly to the absorber body. The welded window design presented permits the weld to be ground off and re-welded. This report presents a thermal FEA analysis of the window seal-weld, while the window is being welded. Finally, the results of a ...
2005-08-24
Validation of WIMS-AECL reactivity device calculations for CANDU reactor
Energy Technology Data Exchange (ETDEWEB)
An important component of the overall program to validate WIMS-AECL for use with RFSP in the analysis of CANDU-6 reactors for design and safety analysis calculations is the validation of calculations of incremental cross sections used to represent reactivity devices. A method has been developed for the calculation of the three-dimensional neutron flux distribution in and around CANDU reactor fuel channels and reactivity control devices. The methods is based on one- and two dimensional transport calculations with the WIMS-AECL lattice cell code, SPH homogenization, and three-dimensional flux calculations with finite-difference diffusion theory using the MULTICELL code. Simulations of Wolsung 1 Phase-B commissioning measurements and Point Lepreau restart tests have been performed, as a part of the program to validate WIMS-AECL lattice cell calculations for application to CANDU reactor simulations in RFSP. The incremental cross section properties of the Wolsung 1 and ...
1997-06-01
Transient enhanced diffusion in preamorphized silicon: the role of the surface
Energy Technology Data Exchange (ETDEWEB)
Experiments on the depth dependence of transient enhanced diffusion (TED) of boron during rapid thermal annealing of Ge-preamorphized layers reveal a linear decrease in the diffusion enhancement between the end-of-range (EOR) defect band and the surface. This behavior, which indicates a quasi-steady-state distribution of excess interstitials, emitted from the EOR band and absorbed at the surface, is observed for annealing times as short as 1 s at 900 deg. C. Using an etching procedure we vary the distance x{sub EOR} from the EOR band to the surface in the range 80-175 nm, and observe how this influences the interstitial supersaturation, s(x). The supersaturations at the EOR band and the surface remain unchanged, while the gradient ds/dx, and thus the flux to the surface, varies inversely with x{sub EOR}. This confirms the validity of earlier modelling of EOR defect evolution in terms of Ostwald ripening, and provides conclusive evidence that ...
1999-01-02
Transient enhanced diffusion in preamorphized silicon: the role of the surface
International Nuclear Information System (INIS)
Experiments on the depth dependence of transient enhanced diffusion (TED) of boron during rapid thermal annealing of Ge-preamorphized layers reveal a linear decrease in the diffusion enhancement between the end-of-range (EOR) defect band and the surface. This behavior, which indicates a quasi-steady-state distribution of excess interstitials, emitted from the EOR band and absorbed at the surface, is observed for annealing times as short as 1 s at 900 deg. C. Using an etching procedure we vary the distance x_E_O_R from the EOR band to the surface in the range 80-175 nm, and observe how this influences the interstitial supersaturation, s(x). The supersaturations at the EOR band and the surface remain unchanged, while the gradient ds/dx, and thus the flux to the surface, varies inversely with x_E_O_R. This confirms the validity of earlier modelling of EOR defect evolution in terms of Ostwald ripening, and provides conclusive evidence that the ...
1999-01-02
Line intensity enhancements in stellar coronal X-ray spectra due to opacity effects
Context. The I(15.01 A)/I(16.78 A) emission line intensity ratio in Fe XVII has been reported to deviate from its theoretical value in solar and stellar X-ray spectra. This is attributed to opacity in the 15.01 A line, leading to a reduction in its intensity, and was interpreted in terms of a geometry in which the emitters and absorbers are spatially distinct. Aims. We study the I(15.01 A)/I(16.78 A) intensity ratio for the active cool dwarf EV Lac, in both flare and quiescent spectra. Methods. The observations were obtained with the Reflection Grating Spectrometer on the XMM-Newton satellite. The emission measure distribution versus temperature reconstruction technique is used for our analysis. Results. We find that the 15.01 A line exhibits a significant enhancement in intensity over the optically thin value. To our knowledge, this is the first time that such an enhancement has been detected on such a sound statistical basis. We interpret ...
2008-01-01
Technology of iodine-131 production and its application
International Nuclear Information System (INIS)
Full text: Production: This radio iodine produced by three methods: 1) Wet method: The irradiated tellurium is dissolved in an oxidizing mixture which also converts iodine in to iodide. This is a chemical method and iodine that it produced with this method has low purity and efficiency. 2). Dry Method: The irradiated tellurium is dissolved in furnace (750 deg. C) with sublimation method and iodine absorbed in sodium solution . In this case we have more than 99.5 % purity and 80 % efficiency. We are using this type in Iran. 3) Fission fragment method: In this case the iodine separated from fission fragment directly and we have high purity (career free) and specific activity of iodine. Application: Iodine is a versatile tracer element. It is used to determine thyroid cancer metastases, and size, shape and activity of the thyroid gland. Critical organ of iodine is thyroid gland. One of the common diagnostic procedures for determining thyroid function therefore, is to ...
Radiation dosimetry of "1"1"1In-oxinate labelled leucocytes
International Nuclear Information System (INIS)
The patients studied were referred for routine abscess localization with indium-111 labelled autologous leukocytes. One series (n=15) was studied at 1 day after reinjection of labelled cells and a second series (n=9) was studied between 4 hours and 4 days after reinjection of labelled cells. The leukocytes were isolated by a gravity sedimentation method and labelled with In-111 oxinate according to Roevekamp and co-workers. The labelled cell suspension administered to the patient contained between 11 and 15 MegaBq (300-400 microCi). The indium-111 concentration in the liver and spleen was quantitated using a scintillation camera and an on-line computer system. Phantom studies were carried out to obtain conversion factors from geometric mean counts to MegaBq of activity for both liver and spleen. Once determined, the amount of activity in liver and spleen was corrected for physical decay of In-111 and expressed as a percentage of the administered activity. Additionally in the 2nd series ...
1982-06-25
Prototype exposure chamber of radon for animal experiments
Energy Technology Data Exchange (ETDEWEB)
To evaluate a dose conversion factor from the `Working Level of Month` (WLM) of radon to the absorbed dose (mGy), the quality of radon and its progeny was assessed, and exposures controlled for each deposition region were planed as follows: 1) exposure of radon gas to the entire respiratory tract, 2) exposure of `unattached` fractions to the upper respiratory tract, 3) exposure of `attached` fractions onto ultrafine particles to the deep lung, 4) exposure of `attached` fractions onto fine particles to the lower respiratory tract, 5) exposure of `attached` fractions onto coarse particles to the upper respiratory tract. In this preliminary study, a prototype exposure system of radon and its progeny for small rodents was designed. A whole body exposure chamber with a volume of about 0.5 m{sup 3} was used, which it held 20 rats. The aging and mixing chamber separated by the exposure chamber had a volume of about 1 m{sup 3}. As ...
1998-12-31
Energy Technology Data Exchange (ETDEWEB)
The optically stimulated luminescence (OSL) results a highly appropriate dosimetric technique for readings of absorbed radiation 'in alive' and 'in situ', as well as in real time. The CVD diamond on the other hand presents excellent qualities like radiation reader thanks to its reproducibility, radiation resistance, biocompatibility and non toxicity. The present work studies the answer of two diamond films pure and polluted with nitrogen (750 ppm) grown by the Chemical Vapor Deposition method (CVD) on silicon substrate (001) irradiated with beta (Sr-90) in the 0.833-100 Gy interval. The optical stimulation was carried out by 40 seconds with infrared laser (830 nm, 0.36 W/cm{sup 2}) and the filter BG-39 (300-600 nm) coupled the PM. The intensity and the decay of the hyperbolic type of the LOE curves were similar in both samples, for the non doped diamond were observed trapping states in 200-380 C being compared with those that it ...
2006-07-01
Neurotoxicological effects of cinnabar (a Chinese mineral medicine, HgS) in mice
International Nuclear Information System (INIS)
Cinnabar, a naturally occurring mercuric sulfide (HgS), has long been used in combination with traditional Chinese medicine as a sedative for more than 2000 years. Up to date, its pharmacological and toxicological effects are still unclear, especially in clinical low-dose and long-term use. In this study, we attempted to elucidate the effects of cinnabar on the time course of changes in locomotor activities, pentobarbital-induced sleeping time, motor equilibrium performance and neurobiochemical activities in mice during 3- to 11-week administration at a clinical dose of 10 mg/kg/day. The results showed that cinnabar was significantly absorbed by gastrointestinal (G-I) tract and transported to brain tissues. The spontaneous locomotor activities of male mice but not female mice were preferentially suppressed. Moreover, frequencies of jump and stereotype-1 episodes were progressively decreased after 3-week oral administration ...
2007-10-15
Gastrointestinal absorption of lead (/sup 203/Pb) in chicks: influence of lead, calcium, and age
Energy Technology Data Exchange (ETDEWEB)
The present study was designed to investigate, in more detail, the mechanism of lead transport by the gastrointestinal tract and particularly the similarities or dissimilarities between lead and calcium in this process. The absorption of these metals was determined in 3-week-old white Leghorn cockerels, raised on a commercial diet or special diets, using an in vivo ligated loop procedure. The dose administered into the loop usually contained 0.5 ..mu..Ci /sup 203/Pb (and/or 0.1 ..mu..Ci /sup 47/Ca), 0.01 mM lead acetate (and/or 1 mM CaCl/sub 2/) in 0.5 ml of 0.15 M NaCl, pH 6.5. It was shown that lead is rapidly taken up by the intestinal tissue, and only slowly transferred into the circulation whereas calcium, also accumulated rapidly by the tissue, is rapidly released from the tissue in the serosal direction. The absorption processes of these cations show similar responses to various experimental conditions (low calcium intake, age of the animal, pH of the ...
1981-10-01
International Nuclear Information System (INIS)
Electron beams as a source of directed energy are under study at the Lawrence Livermore National Laboratory (LLNL). An intense 10-kA, 50-MeV, 50-ns full-width half-maximum, pulsed electron beam is generated by the prototype Advanced Test Accelerator (ATA) at the Laboratory's Site 300. Whenever the electron beam is stopped in materials, intense radiation is generated. Estimates based on available data in the literature show that for materials such as lead, photon radiation (x ray, gamma, bremsstrahlung) levels can be as large as 10"4 roentgens per pulse at 1 m in the zero-degree direction (i.e., the electron-beam direction). Neutrons, which are emitted isotropically, are produced at a level of 10"1"3 n/m"2 per pulse. Depending upon the number of pulses and the shielding geometry, the accumulated dose is potentially lethal to personnel and potentially damaging to instrumentation that may be used for diagnostics. To provide shielding for minimizing the risk of ...
International Nuclear Information System (INIS)
A quantitative comparison of tissue distribution and excretion of an orally administered sublethal dose of [3H]diacetoxyscirpenol (anguidine) was made in rats and mice 90 min, 24 hr, and 7 days after treatment. Total recoveries of 95-100% were obtained. Approximately 90% of the dose was excreted in urine and feces during the first 24 hr with a feces:urine ratio of about 1:4.5 in both species. Carcass and tissue radioactivity dropped rapidly during the first 24 hr but remained relatively constant at low, but detectable, levels over the course of the experiment. Few substantive interspecies differences were noted in tissue distribution. At 90 min the highest percentage of dose was in tissues involved in sequestering diacetoxyscirpenol because of high body water/lipid content or the absorption, metabolism, or excretion of the toxin. The rank order of these tissues was generally stable ...
Monte Carlo simulation and dosimetric verification of radiotherapy beam modifiers
International Nuclear Information System (INIS)
Monte Carlo simulation of beam modifiers such as physical wedges and compensating filters has been performed with a rectilinear voxel geometry module. A modified version of the EGS4/DOSXYZ code has been developed for this purpose. The new implementations have been validated against the BEAM Monte Carlo code using its standard component modules (CMs) in several geometrical conditions. No significant disagreements were found within the statistical errors of 0.5% for photons and 2% for electrons. The clinical applicability and flexibility of the new version of the code has been assessed through an extensive verification versus dosimetric data. Both Varian multi-leaf collimator (MLC) wedges and standard wedges have been simulated and compared against experiments for 6 MV photon beams and different field sizes. Good agreement was found between calculated and measured depth doses and lateral dose profiles along both wedged and unwedged directions for ...
2001-11-01
International Nuclear Information System (INIS)
7,959 patients were examined by radionuclide in-vivo methods within one year, 1,228 of them by application of "1"3"1I-iodide (radioiodine test and scintigraphy of the thyroid gland). In compliance with the ICRP publications 26 and 27 the somatically effective equivalent dose H/sub s,eff/ was ascertained for several examining methods, derived from it the collective dose S/sub s,eff/ and considering a part of manifestation resulting from the age distribution of patients, the somatic risk regarding radiation-induced malignoma with fatal termination. For the patients examined by "1"3"1I-iodide the collective dose was 79.9 man x Sv and the mean somatic risk 30 x 10"-"5 with a part of manifestation of 0.39 accordig to 0.37 radiation-induced malignomas with fatal termination. For all patients examined by other radiopharmaceuticals the collective dose was 14.07 man x Sv, the mean somatic ...
1986-01-01
A deterministic partial differential equation model for dose calculation in electron radiotherapy
International Nuclear Information System (INIS)
High-energy ionizing radiation is a prominent modality for the treatment of many cancers. The approaches to electron dose calculation can be categorized into semi-empirical models (e.g. Fermi-Eyges, convolution-superposition) and probabilistic methods (e.g. Monte Carlo). A third approach to dose calculation has only recently attracted attention in the medical physics community. This approach is based on the deterministic kinetic equations of radiative transfer. We derive a macroscopic partial differential equation model for electron transport in tissue. This model involves an angular closure in the phase space. It is exact for the free streaming and the isotropic regime. We solve it numerically by a newly developed HLLC scheme based on Berthon et al (2007 J. Sci. Comput. 31 347-89) that exactly preserves the key properties of the analytical solution on the discrete level. We discuss several test cases taken from the medical physics literature. ...
2010-07-07
Energy Technology Data Exchange (ETDEWEB)
The radionuclide characteristics of light-water-reactor (LWR) spent fuel play key roles in the design and licensing activities for radioactive waste transportation systems, interim storage facilities, and the final repository site. Several areas of analysis require detailed information concerning the time-dependent behavior of radioactive nuclides including (1) neutron/gamma-ray sources for shielding studies, (2) fissile/absorber concentrations for criticality safety determinations, (3) residual decay heat predictions for thermal considerations, and (4) curie and/or radiological toxicity levels for materials assumed to be released into the ground/environment after long periods of time. The crucial nature of the radionuclide predictions over both short and long periods of time has resulted in an increased emphasis on thorough validation for radionuclide generation/depletion codes. Current radionuclide generation/depletion codes have the capability to follow the ...
1995-01-01
... energy absorption characteristics of composite sandwich panels, thermoplastic energy-absorbing subfloor structures, and shoulder belt pre- tensioners. ...
Comparison of beam-induced deposition using ion microprobe
International Nuclear Information System (INIS)
The localized Pt deposition on Si by 30 keV Ga"+ focused ion beam (FIB), 10 keV electron beam (EB) or dual beams (FIB and EB) using precursor gas has been compared by analysis using a 300 keV Be"2"+ microprobe with a beam spot size of 80 nm. The distribution of deposited Pt, Ga from the ion beam itself, and C from the precursor gas was obtained at and nearby the deposited areas by micro-RBS spectra and RBS mapping. All of the beam processed areas showed a uniform Pt distribution at the deposited areas. The amount of Pt atoms increased with the increase in ion or electron dose due to the decomposition of precursor gas. The thickness of Pt layer by EB is considerably less than that by FIB due to the reduced deposition rate. Ga atoms from the center of processed areas partly redeposited at and nearby the FIB processed areas within #approx#3 #mu#m. The Ga incorporation by dual beam processing was reduced compared with that by ...
1999-01-02
Concepts of radiotherapy treatment planning
International Nuclear Information System (INIS)
Full text: Radiotherapy treatment planning (RTP) relies heavily on medical imaging. Until recently, the most important planning tool was the treatment simulator. The kilovoltage radiographic capabilities in a treatment simulator enabled the boundaries of treatment fields to be visualized with respect to bony anatomic landmarks. Perhaps the most important advance in treatment planning in recent years is the ability to visualize the passage of the beams with respect to a more accurate geometrical representation of the tumor and other soft tissue structures. This 'virtual simulation' uses a computer-based representation of a patient to determine the extent of the disease and the location of radiation sensitive normal tissue. Computer tomographic (CT) imaging produces a high-resolution three-dimensional representation of anatomy that can be correlated with other image sets such as magnetic resonance images (MRI) of function. Positron emission tomographic (PET) imaging is beginning to be ...
2000-12-01
Random motion of a particle emitting and absorbing tachyons
International Nuclear Information System (INIS)
Random motion of a particle, emitting and absorbing tachyons, is investigated. It is shown that if bradyon is in equilibrium with neutral gas, i.e. it absorbs and emits tachyons, which do not have any charges, tha particle with each absorption-emittance of a tachyon changes its energy and momentum, never varying its own mass, and as a result it moves like a brownian particle. Thus, bradyon, interacting with tachyon gas, increases its momentum continuously in agreement with the Einstein-Fokker-Planck type equation.
Radiation receiver. Strahlungsempfaenger
Energy Technology Data Exchange (ETDEWEB)
The purpose of the invention is to improve a radiation receiver, consisting of a hollow body with an opening for the entry of radiation and a ceramic absorber situated in the hollow body, which absorbs the radiation energy entering through the opening, and emits it as thermal radiation to a heat medium, so that a higher efficiency can be achieved. According to the invention, the problem is solved by the fact that the absorber consists of ceramic material on the side towards the solar radiation, which has a low emission value and a high absorption value, and that the side of the absorber towards the heat medium has ceramic material of high emission value and low absorption value. This ensures that reradiation is prevented near the opening of the hollow body, and that the solar energy entering is largely absorbed in the hollow body.
1981-10-01
Optical effects of fine-particle carbon on urban atmospheres
Energy Technology Data Exchange (ETDEWEB)
The effects of fine-particle C, such as diesel soot, on the optical properties of urban haze in the visible wavelength range were explored to determine the dominant effects and to see if simple parameters (such as visual range in green) provide an adequate measure of these effects. It is known that fine-particle C absorbs more strongly in the blue than in the red, so that when it is mixed with a white pigment, the resulting gray can appear somewhat brown. The possibility of a similar effect in urban hazes was investigated, but found not to occur. When the sun is overhead, the near-horizon sky chromaticities caused by mixtures of fine-particle C and non-absorbing aerosol can also be produced by non-absorbing aerosols alone. It is shown that absorbing aerosol will darken the horizon sky, and a simple equation for the radiance of the horizon sky is derived. The effect of absorbing ...
1986-01-01
Energy Technology Data Exchange (ETDEWEB)
In this work a study of simulation of the gamma graphic studies that are carried out in human esophagus in the Dept. of Nuclear Medicine of the 'Celestino Hernandez Robau Hospital of Santa Clara is presented. For the investigation tubular reactors were used and sting-response techniques with radioactive tracer of Technetium 99 metastable to a concentration of 1 mCi and several flows were applied. The distribution curves of residences times were obtained, those that respond to an equation of the type: Y = A + B exp (- exp((x-C)/D)) - ((x-C/D)+1). They were also carried out, optimizations studies of the doses of the radioactive to give to the patients from 1 mCi (that is the one used in studies) up to 0,5 mCi, and the influences on the obtained distributions of residence time were analyzed. It was confirmed the possibility to lower the doses with clear information of the signal. It was also ...
2003-07-01
International Nuclear Information System (INIS)
The focus of this study is to validate whether the sensitivity of dose distribution following the interface of different media can be used to distinguish between small variations of photon energy spectra in the context of the convolution/superposition algorithm in the polyenergetic implementation (Philips Pinnacle"3, ADAC Laboratories, Milpitas, CA). Calculations were performed in homogeneous water and heterogeneous lung/water phantoms. Spectra were generated, in which the weights of the low-, medium- and high-energy components were adjusted sequentially. The heterogeneity correction factor CF_l_u_n_g, the D_2_0/D_1_0 ratio for homogeneous water and logarithmic derivative in buildup region LD_b_u_i_l_d_u_p were assessed for their relative ability to discriminate between different spectra for various field sizes. In accordance with another study (Charland et al 2004), the superior discrimination ability of the CF_l_u_n_g and LD_b_u_i_l_d_u_p ...
2004-09-21
Mechanisms of cobalt uptake in plants: {sup 60}Co uptake and distribution in Chara
Energy Technology Data Exchange (ETDEWEB)
The mechanism of cobalt uptake was investigated using cells of the giant alga Chara corallina in which it is possible to resolve separately uptake by the cell wall and actual influx across the cell membrane. The absorption of {sup 60}Co by Chara cells appeared to saturate within 2 h. but this was mainly due to rapid uptake into the cell wall which accounted for 87-92% of the total activity. Even after prolonged desorption most of the cell-associated {sup 60}Co was found on the cell wall. The intracellular distribution of absorbed {sup 60}Co was investigated by fractionating the cell into cytoplasm and vacuole. It was shown that {sup 60}Co influx to the vacuole occurs simultaneously with influx to the cytoplasm. The transported species appears to be Co{sup 2+} rather than the less charged Co(OH){sup +} or Co(O){sub 2}. {sup 60}Co influx is pH dependent (optimum pH 7-9), and is sensitive to some other divalent metals. Influx from solutions ...
1998-12-31
Mechanisms of cobalt uptake in plants: "6"0Co uptake and distribution in Chara
International Nuclear Information System (INIS)
The mechanism of cobalt uptake was investigated using cells of the giant alga Chara corallina in which it is possible to resolve separately uptake by the cell wall and actual influx across the cell membrane. The absorption of "6"0Co by Chara cells appeared to saturate within 2 h. but this was mainly due to rapid uptake into the cell wall which accounted for 87-92% of the total activity. Even after prolonged desorption most of the cell-associated "6"0Co was found on the cell wall. The intracellular distribution of absorbed "6"0Co was investigated by fractionating the cell into cytoplasm and vacuole. It was shown that "6"0Co influx to the vacuole occurs simultaneously with influx to the cytoplasm. The transported species appears to be Co"2"+ rather than the less charged Co(OH)"+ or Co(O)_2. "6"0Co influx is pH dependent (optimum pH 7-9), and is sensitive to some other divalent metals. Influx from solutions containing 1 #mu#M "6"0Co was inhibited ...
1998-01-01
Energy Technology Data Exchange (ETDEWEB)
The theoretical analysis of a partially-ionized hydrogen gas flow (gas temperatures of approximately 10,000 to 20,000 K) through a particular class of magnetohydrodynamic (MHD) generators and the preliminary design of these MHD generators as open cycle, electric power supplies are performed. Analysis of the gas flow through these ultra-high temperature MHD generators requires a coupled gas dynamics/radiative heat transfer solution. Gas dynamics are modeled by a set of quasi-one-dimensional, nonlinear differential equations which account for friction, convective and radiative heat transfer and the interaction between the ionized gas and applied magnetic field. Radiative heat transfer is modeled using non-gray, absorbing-emitting two- and three-dimensional P-1 approximations which permit an arbitrary variation of the spectral absorption coefficient with frequency. Gas dynamics and radiative heat transfer are coupled through the energy equation, and through the ...
1990-01-01
Application of dose factors for decay chains
International Nuclear Information System (INIS)
... dose rates inhalation iodine 134 krypton 88 nuclear decay quality factor
International Nuclear Information System (INIS)
For the Convolution, Superposition and Monte Carlo methods, energy spectrum data is an essential parameter. Especially, by using Monte Carlo method, if the adequate properties of electrons are set, complex energy spectrum data can be calculated by simple input. However, adjustment of the property of electrons incident on the target of linear accelerator is time-consuming procedure. To cover the difference of many accelerators, it is important how we obtain accurate energy spectrum by simple methods. Especially, the total accuracy of dose calculation depends on the agreement of measured and calculated percentage depth dose (PDD) and off-axis ratio (OAR). Thus, a simple method for the determination of the simulation parameters was considered. To reduce the adjustment procedure, we selected values of important three parameters, which were the mean energy of the input electron beam, the energy distribution of the input electron ...
2005-06-01
International Nuclear Information System (INIS)
For a given linac design, the dosimetric characteristics of a photon beam are determined uniquely by the energy and radial distributions of the electron beam striking the x-ray target. However, in the usual commissioning of a beam from measured data, a large number of variables can be independently tuned, making it difficult to derive a unique and self-consistent beam model. For example, the measured dosimetric penumbra in water may be attributed in various proportions to the lateral secondary electron range, the focal spot size and the transmission through the tips of a non-divergent collimator; the head-scatter component in the tails of the transverse profiles may not be easy to resolve from phantom scatter and head leakage; and the head-scatter tails corresponding to a certain extra-focal source model may not agree self-consistently with in-air output factors measured on the central axis. To reduce the number of adjustable variables in beam modelling, we replace ...
2005-09-07
Medical consequences of radiation accidents
International Nuclear Information System (INIS)
Since 1945, more than 1.8 x 10"2"1 Bq of artificial radionuclides have been released into the atmosphere. Approximately 2.04 x 10"1"8B, i.e. approx. 0.11%, are the result of accidents at nuclear industrial facilities. This percentage is causing increased interest among researchers. This is due to the fact that in the wake of accidental release radionuclides become distributed unevenly across the Earth's surface, and the associated exposures, fluctuating from background level to several grays, an induce both stochastic and deterministic effects in the irradiated population. A comparative analysis of the medical consequences of the twentieth century's most serious nuclear events, namely the authorized dumping of high level radioactive waste into the river Techa in 1950, the explosion of a storage tank containing long lived radioactive waste in the Southern Urals in 1957, the fire at Sellafield in 1957 and the accident at the Chernobyl nuclear power plant in 1986, has ...
1995-10-01
Disposal of old heads for Daya Bay NPP
International Nuclear Information System (INIS)
The paper introduces the disposal procedures of the old reactor pressure vessel head. Reactor pressure vessel (RPV) heads were replaced successfully in Daya Bay Nuclear Power Plant. The on-site treatment and disposal of replaced heads was thereafter implemented. This is the first time in China for large size radioactive article disposal. To guarantee the safety of old head treatment, issues of radiation protection have to be taken into account. Dose rate distribution of the old head surface and radioactivity were initially calculated according to the operation history and the neutron flux rate of the reactor. Shielding calculation and package design was thereafter worked out based on the data obtained from the old head, e.g. neutron flux, sorts of nuclides, radioactivity and dose rates. Shielding package was afterwards manufactured in special factories and transported to Daya Bay NPP site by truck and ship. The shielding ...
Development of an irradiation system for a small size continuous run multipurpose gamma irradiator
International Nuclear Information System (INIS)
The Radiation Technology Center from IPEN-CNEN/SP, Brazil, developed a revolutionary design and national technology, a small-sized continuous run and multipurpose industrial gamma irradiator, to be used as a demonstration facility for manufacturers and contract service companies, which need economical and logistical in-house irradiation system alternatives. Also, to be useful for supporting the local scientific community on development of products and process using gamma radiation, assisting the traditional and potential users on process validation, training and qualification of operators and radioprotection officers. The developed technology for this facility consists of a continuous tote box transport system, comprising a single concrete vault, where the automated transport system of products inside and outside of the irradiator utilizes a rotating door, integrated with the shielding, avoiding the traditional maze configuration. Covering 76 m"2 of floor area, the irradiator design is ...
International Nuclear Information System (INIS)
At Tarapur Atomic Power Station 3 and 4, 540 MWe Pressurised Heavy Water Reactors, core being large in size requires a continuous in core monitoring for local flux disturbances. Nearly 200 Self Powered Neutron Detectors (SPNDs) of the Straight Individually Replaceable (SIR) type are distributed in the reactor core. For purpose of reactor regulation and protection, cobalt SPNDs that have a prompt response for changes in power is used for in-core flux mapping, vanadium SPNDs that provide accurate measure of neutron flux, even though having slow response is used In core SPNDs are placed in Vertical Flux Units (VFU) and Horizontal Flux Units (HFUs). These SPNDs were to be replaced at regular intervals to meet the design intent. Cobalt SPNDs have dose rates of the order of 1000 Gy/h and the Mineral Insulated (MI) cables of Vanadium SPNDs have dose rates of the order of 100 Gy/h. So far 3 Cobalt SPNDs were removed from HFUs and ...
2006-11-13
Natural radionuclides in drinking water in Argentina
International Nuclear Information System (INIS)
As part of the national survey to evaluate natural radioactivity in the environment, concentration levels of natural uranium and "2"2"6Ra have been analyzed in over 300 drinking water samples taken from different locations in Argentina. "2"2"6Ra was determined by "2"2"2Rn emanation and liquid scintillation counting, and natural uranium by a fluorimetric procedure. Values ranging from 0.03 to 24 #mu#g.l"-"1 of natural uranium and from 0.06 to 50 #mu#g.l"-"1, were measured on drinking water samples taken from tap water systems and private wells, respectively. Concentrations up to 15 mBq.l"-"1 and to 22 mBq.l"-"1 of "2"2"6Ra were found in drinking water samples taken from tap water systems and private wells, respectively. These values are compared with the reference values accepted for drinking water. Based on the water intake rate, the age distribution and the measured concentrations, an annual collective effective dose of 1.9 man Sv and an ...
2000-05-01
Environmental impact assessment around TRIGA research reactor
International Nuclear Information System (INIS)
Population distribution, atmospheric change, X/Q, characteristics of terrestrial ecosystem around Seoul site were surveyed. Environmental radiation and radioactivities such as gross#alpha#, gross#beta#, Cs-137, Sr-90 and H-3 of various environmental samples were analyzed. The values of environmental radiation dose tended to increase gradually in the light of the recent five years' results of environmental radiation monitoring around the nuclear power plants from 1980 to 1984, however, the changes were not significant. In addition, continuous assessment of environmental radiation monitoring on the roofs of main building and life science building at KAERI showed that the environmental radiation dose tended to increase a little during the night time. Judging from the above results, it is concluded that environmental contamination level by radioactive materials could be ignored in the case of radioisotope production or ...
1985-04-01
Depth dependence of defect evolution and TED during annealing
Energy Technology Data Exchange (ETDEWEB)
A quantitative transmission electron microscopy (TEM) study on the depth profile of extended defects, formed after Si implantation, has been carried out. Two different Si{sup +} implant conditions have been considered. TEM analysis for the highest energy/dose shows that {l_brace}1 1 3{r_brace} defects evolve into dislocation loops whilst the defect depth distribution remains unchanged as a function of annealing time. For the lowest energy/dose, {l_brace}1 1 3{r_brace} defects grow and dissolve while the defect band shrinks preferentially on the surface side. At the same time, extraction of boron transient enhanced diffusion (TED) as a function of depth shows a decrease of the supersaturation towards the surface, starting at the location of the defect band. The study clearly shows that in these systems the silicon surface is the principal sink for interstitials. The results provide a critical test of the ability of physical ...
2004-02-01
Depth dependence of defect evolution and TED during annealing
International Nuclear Information System (INIS)
A quantitative transmission electron microscopy (TEM) study on the depth profile of extended defects, formed after Si implantation, has been carried out. Two different Si"+ implant conditions have been considered. TEM analysis for the highest energy/dose shows that #left brace#1 1 3#right brace# defects evolve into dislocation loops whilst the defect depth distribution remains unchanged as a function of annealing time. For the lowest energy/dose, #left brace#1 1 3#right brace# defects grow and dissolve while the defect band shrinks preferentially on the surface side. At the same time, extraction of boron transient enhanced diffusion (TED) as a function of depth shows a decrease of the supersaturation towards the surface, starting at the location of the defect band. The study clearly shows that in these systems the silicon surface is the principal sink for interstitials. The results provide a critical test of the ability of ...
2004-02-01
International Nuclear Information System (INIS)
In the report the results of the estimations of radiological risk of various stages of decommissioning of nuclear submarines are presented. At occurrence on nuclear submarine the heavy failure, relating to the class hypotetical volume of acting of radionuclides in atmosphere can reach 1.6E(15) Bq. Results of estimations probable doses on an axis of a trace of a radioactive loop show, that at distribution of radionuclides during atmospheric carry to 'agreed' settlement (500-1000 m) the maximum doses on its territory can make: about 6.0E(-3) Sv (for the whole body); 3.0E(-3) Gy for the leather (basal layer); 6.3E(-2) Gy for the lungs (acute exposure) and up to 1.8 Gy for the thyroid gland. Hypotetical failure for the estimation of the greatest possible radioecological consequences for hydrobiocenosis is considering, connected with single discharge of liquid radioactive waste (LRW) in water area. At navigating failure of the ...
2000-05-01
Energy Technology Data Exchange (ETDEWEB)
Iodized oil has been used as a contrast agent in lymphangiography. One of the commercially available compounds is Lipidol Ultra-fluid(LUF) which contains 38% iodine by weight. Nakakuma et al(1979) reported that LUF was selectively retained in the hypervascular hepatocellular carcinoma when injected directly into the ligated hepatic artery. Since that time, it has been widely utilized in the detection as well as the therapeutic attempts of hepatocellular carcinoma, where it has been mixed with chemotherapeutic agents or labeled with radioactive I-131. Like all significant advances, the mechanism of lipid retention within the hepatocellular carcinoma is not clearly understood, and also there is a lack of information about the biodistribution and kinetics of I-131 Lipiodol. The apparent safety of this technique require confirmation. The present study was aimed to assess the biodistribution and kinetics of intraarterially injected I-131 Lipiodol and the histologic changes in canine livers. ...
1989-08-15
Energy Technology Data Exchange (ETDEWEB)
To determine a suitable combination of X-ray filter and tube kilovoltage for Fuji Computed Radiography (FCR), provide better detection of pulmonary nodules, and reduce patient exposure, we compared observer performance with different X-ray filters and tube voltages. Radiographs were obtained with a copper filter backed by aluminium, with a tungsten filter backed by yttrium and aluminium, and with a lead filter backed by yttrium and aluminium, at both 100 kVp and 135 kVp. Observer performance in detecting simulated lung nodules, which were placed on the posterior aspect of a chest phantom, was compared using receiver operating characteristic (ROC) techniques for each combination of the X-ray filter and tube voltage. The results of the study indicated that (1) nodule detection was superior for the images obtained with 135 kVq as compared with 100 kVp; (2) approximately equal detection rates were obtained for the three X-ray filter sets, although results with the tungsten filter were ...
1994-10-01
International Nuclear Information System (INIS)
To determine a suitable combination of X-ray filter and tube kilovoltage for Fuji Computed Radiography (FCR), provide better detection of pulmonary nodules, and reduce patient exposure, we compared observer performance with different X-ray filters and tube voltages. Radiographs were obtained with a copper filter backed by aluminium, with a tungsten filter backed by yttrium and aluminium, and with a lead filter backed by yttrium and aluminium, at both 100 kVp and 135 kVp. Observer performance in detecting simulated lung nodules, which were placed on the posterior aspect of a chest phantom, was compared using receiver operating characteristic (ROC) techniques for each combination of the X-ray filter and tube voltage. The results of the study indicated that 1) nodule detection was superior for the images obtained with 135 kVq as compared with 100 kVp; 2) approximately equal detection rates were obtained for the three X-ray filter sets, although results with the tungsten filter were ...
1994-01-01
Self-expandable stent loaded with {sup 125}I seeds: Feasibility and safety in a rabbit model
Energy Technology Data Exchange (ETDEWEB)
Objective: To evaluate technical feasibility and acute and subacute radiotolerance of a self-expandable stent loaded with {sup 125}I seeds in the rabbit esophagus. Methods: A self-expandable stent designed for esophageal application was made of 0.16 mm nitinol wire and loaded with {sup 125}I seeds (CIAE-6711). Twenty-seven stents with three different radioactive dosages (n = 9 in each dosage group) were implanted in the esophagus of healthy rabbits, while nine stents alone were used as controls. The stents were perorally deployed into the esophagus under fluoroscopic guidance. Radiological follow-up included plain chest film, CT scan, and barium esophagography which were undertaken in all rabbits of each group at 2, 4, and 8 weeks, respectively, which were correlated to histopathological findings. The stented esophageal segments along with their adjacent tissues were harvested for histopathological examinations. Results: The stent was successfully deployed into the targeted esophageal ...
2007-02-15
International Nuclear Information System (INIS)
The mechanism of lead transport is presented, and especially the particular similarities or dissimilarities between lead and calcium in this process. The absorption of these metals was determined cockerels, raised on a commercial diet or on a specified diet, using in vivo ligated loop procedure. The dose administered into the loop contained 0.5 #mu#Ci "2"0"3Pb (and/or 0.1 #mu#Ci "4"7Ca), and 0.01 mM lead acetate (and/or mM CaCl_2) in 0.5 ml 0.15 M NaCl,pH 6.5. It was shown that lead is rapidly taken up by the mucosal tissue, and slowly transferred into the body, whereas less calcium is retained by the tissue and the transfer of calcium is many times as effective as that for lead. They appear to respond in a similar manner to a low calcium intake and vitamin D treatment. Increasing luminal stable lead concentration significantly reduced the percentage of radiolead significantly reduced the percentage of radiolead absorbed, but did not affect the ...
Energy Technology Data Exchange (ETDEWEB)
Two neutron emesis experiments were conducted at the Armed Forces Radiobiology Research Institute (AFRRI). In both experiments (described as Phase I and Phase II) the radiation dose required to cause emesis in 50% of subjects (ED50) was determined for both neutron reactor and gamma reactor source radiation. Emesis onset, offset and duration times post-exposure are reported. Neutrons were maximized from the reactor by passing the beam through a 15.25 cm (6 in.) thick lead wall to filter out gamma photons. Gamma rays were maximized by thermalizing neutrons in 30.5 cm (12 in.) of water, then absorbing the thermal neutrons in a gadolinium-cadmium shield. In Phase I, 28 dogs were exposed to radiation: 12 were exposed to gamma photons at the rate of 0.69 Gy/min and 16 were exposed to neutrons at 1.2 Gy/min. In Phase II, 58 dogs in 3 groups were exposed to radiation: 19 were exposed in the gamma group at 0.75 Gy/min, 20 were exposed in the undrugged ...
1985-08-01
Effect of vitamin D on the intestinal absorption of 203Pb and 47Ca in chicks
Energy Technology Data Exchange (ETDEWEB)
The transfer of 203Pb and/or 47Ca across the intestinal epithelium of the chick was investigated, with emphasis given to the functional role of cholecalciferol (vitamin D-3). 203Pb, after introduction in the intestinal lumen, is rapidly accumulated by the intestinal tissue, and only a fraction of 203Pb is translocated parenterally (absorbed). Cholecalciferol did not significantly affect the accumulation of 203Pb by intestinal tissue but did accelerate 203Pb movement across the basal-lateral membrane. In contrast, cholecalciferol both decreased 47Ca tissue levels and increased 47Ca absorption. In rachitic chicks, the rate of absorption of 203Pb was greater in the distal than in the proximal segments of the intestine; after cholecalciferol repletion, the degree of absorption in al segments was similar, indicting the order of cholecalciferol effectiveness as duodenum greater than or equal to jejunum greater than ileum. An acute dose of 1,25(OH)2D3 ...
1982-03-01
Effect of vitamin D on the intestinal absorption of /sup 203/Pb and /sup 47/Ca in chicks
Energy Technology Data Exchange (ETDEWEB)
The transfer of /sup 203/Pb and/or /sup 47/Ca across the intestinal epithelium of the chick was investigated, with emphasis given to the functional role of cholecalciferol (vitamin D-3). /sup 203/Pb, after introduction in the intestinal lumen, is rapidly accumulated by the intestinal tissue, and only a fraction of /sup 203/ Pb is translocated parenterally (absorbed). Cholecalciferol did not significantly affect the accumulation of /sup 203/Pb by intestinal tissue but did accelerate /sup 203/Pb movement across the basal-lateral membrane. In contrast, cholecalciferol both decreased /sup 47/Ca tissue levels and increased /sup 47/Ca absorption. In rachitic chicks, the rate of absorption of /sup 203/Pb was greater in the distal than in the proximal segments of the intestine; after cholecalciferol repletion, the degree of absorption in all segments was similar, indicating the order of cholecalciferol effectiveness as duodenum greater than or equal to jejunum > ileum. ...
1982-03-01
Dosimetry audit on the accuracy of 192Ir brachytherapy source strength determinations in Sweden
Energy Technology Data Exchange (ETDEWEB)
The absorbed dose delivered to the patient in brachytherapy is directly proportional to the source strength in terms of the reference air-kerma rate (RAKR). Verification of this quantity by the hospitals is widely recognized as an important part of a quality assurance program. An external audit was performed on behalf of the Secondary Standard Dosimetry Laboratory at the Swedish Radiation Protection Authority (SSI). The aim was to investigate how accurately the source-strength in 192Ir brachytherapy is determined at Swedish hospitals. The SSI reference well-type ion chamber and calibrated equipment were used to measure the RAKR of an 192Ir source in each of the 14 Swedish afterloading units. Comparisons with values determined by vendors and hospitals were made. Agreement in values of RAKR as determined by SSI, hospitals and vendors were in all cases within the +-3% uncertainty (at a coverage factor of k=2), typically guaranteed by the vendors. ...
2007-11-15
Radioactive iodine absorbing properties of tetrathiafulvalene
Energy Technology Data Exchange (ETDEWEB)
For the purpose of searching some effective absorbents of gaseous radioactive iodine, 16 substances considered as having an affinity for iodine were investigated with regular iodine and /sup 125/I. In a preliminary survey, only tetrathiafulvalene (TTF) was found to have satisfactory absorbing properties comparable to activated charcoal. A further detailed comparison of the properties between TTF and activated charcoal led us to the conclusion that the former has more preferable properties as absorbent of radioactive iodine than the latter in all points studied. The results are summarized as follows: (1) The absorption of iodine on TTF in atmosphere was about twice as much as that on activated charcoal. Desorption of iodine from saturatedly absorbed iodine on TTF was practically negligible except trace amount of initial desorption, while that on activated charcoal was considerable (3%/50h) even in the ...
1989-05-01
Theoretical considerations for X-ray phase contrast mammography by Thomson source
Energy Technology Data Exchange (ETDEWEB)
The advent, in the near future, of compact X-ray sources like Thomson Back-Scattering (TBS) will allow the clinical application of advanced X-ray imaging techniques, such as phase contrast, with higher sensitivity and lower impact in terms of dose delivery. In this work, we theoretically investigated the possibility of using such sources for phase contrast imaging of micro-calcifications included in a breast tissue. In our study we analyzed the phase and amplitude distribution of the TBS source and we showed that this source can be used for phase contrast imaging since the source coherence at the sample position is sufficiently high for achieving good contrast and micrometer spatial resolution. Indeed the spatial coherence of a TBS source is closer to that of a synchrotron radiation source, and much better than that of a laboratory source. Moreover, we showed the advantages of phase imaging with respect to standard absorption imaging, in the ...
2009-09-01
Synthesis and tissue distribution study of iodine-labeled benzyl- and xylylamines
International Nuclear Information System (INIS)
Four "1"2"5I labeled mono- and diamines were prepared and evaluated as potential brain-imaging agents. The diamines are analogues of the previously reported "7"5Se labeled diamines, which show high brain uptake and retention. All of the radioiodinated amines display high initial brain uptake in rats after intravenous injection (1.7-2.4% dose/organ). The xylylenediamines show prolonged brain retention (t1/2 approximately 18 h), which is desirable for brain imaging. In contrast, the benzylamine is rapidly cleared from brain tissue (t1/2 approximately 15 min).
Energy Technology Data Exchange (ETDEWEB)
RESRAD was one of the multimedia models selected by the US Nuclear Regulatory Commission (NRC) to include in its workshop on radiation dose modeling and demonstration of compliance with the radiological criteria for license termination. This paper is a summary of the presentation made at the workshop and focuses on the 10 questions the NRC distributed to all participants prior to the workshop. The code selection criteria, which were solicited by the NRC, for demonstrating compliance with the license termination rule are also included. Among the RESRAD family of codes, RESRAD and RESRAD-BUILD are designed for evaluating radiological contamination in soils and in buildings. Many documents have been published to support the use of these codes. This paper focuses on these two codes. The pathways considered, the databases and parameters used, quality control and quality assurance, benchmarking, verification and validation of these codes, and ...
1998-05-01
Neutron and gamma-ray penetrations in thick iron
Energy Technology Data Exchange (ETDEWEB)
Measurements of neutron and gamma-ray penetrations in an iron shield were performed up to a 60-cm depth in a tightly coupled source shield configuration with the fast-neutron reactor YAYOI as a source. Rates of neutron reactions and gamma-ray dose rates in the iron shield were obtained using activation foils and thermoluminescent dosimeters. Analyses of the experiments were made by using the DOT-III code with coupled neutron and gamma-ray cross sections from ENDF/B-IV and POPOP4 libraries. To obtain the source condition for the iron shield analyses, the calculated spectrum was adjusted to the measured reaction rates at the reactor shield boundary. The calculated neutron and gamma-ray distributions in the iron shield show fairly good agreement with the experiments. The effect of difference in Bondarenko-type self-shielding factors on the analyses of the iron shield is also shown.
1980-03-01
MCNP study for epithermal neutron irradiation of an isolated liver at the Finnish BNCT facility
International Nuclear Information System (INIS)
A successful boron neutron capture treatment (BNCT) of a patient with multiple liver metastases has been first given in Italy, by placing the removed organ into the thermal neutron column of the Triga research reactor of the University of Pavia. In Finland, FiR 1 Triga reactor with an epithermal neutron beam well suited for BNCT has been extensively used to irradiate patients with brain tumors such as glioblastoma and recently also head and neck tumors. In this work we have studied by MCNP Monte Carlo simulations, whether it would be beneficial to treat an isolated liver with epithermal neutrons instead of thermal ones. The results show, that the epithermal field penetrates deeper into the liver and creates a build-up distribution of the boron dose. Our results strongly encourage further studying of irradiation arrangement of an isolated liver with epithermal neutron fields.
2004-11-01
Energy Technology Data Exchange (ETDEWEB)
Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 MeV is desirable. Key words: neutron--gamma spectra, spectrometry, kerma distributions, coupled multigroup ...
1983-01-01
International Nuclear Information System (INIS)
Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 MeV is desirable. Key words: neutron--gamma spectra, spectrometry, kerma distributions, coupled multigroup ...
7871-01-01
Scatter measurements for optical cone-beam computed tomography
Energy Technology Data Exchange (ETDEWEB)
Both x-ray and optical cone-beam CT (CBCT) scanners are limited by scattered photons that contaminate the primary images. Transparent radiochromic gels and plastics are anticipated to produce less scattering than polymerization gels and hence result in reconstructed dose distributions with greater contrast and dynamic range. Four methods of scatter measurement were investigated to quantify scatter fractions using an in-house optical CBCT scanner. The methods consisted of generating either 'coin' shadows or primary beamlets in transmission images. The four methods generated similar results of 10% scatter fractions in gel transmission images for this particular scanner configuration with both leuco crystal violet and carbon black micelle gels. The scatter contributions were distributed as 5% from micelle gel, 2% from Teflon wall, 2% from refractive index matching liquid and 1% other sources. Applying a ...
2009-05-01
Carbon dioxide absorption methanol process
Energy Technology Data Exchange (ETDEWEB)
This patent describes a process for removing carbon dioxide from a feed stream of natural gas having at least methane, ethane and heavier. It comprises: first, separating the feed stream in a first separator to form a first stream having substantially all of the propane and heavier hydrocarbons and carbon dioxide and ethane and a second stream, having methane, carbon dioxide and ethane; separating the second stream in a second separator into a stream of carbon dioxide product and a third stream having ethane, methane and carbon dioxide: mixing at least a portion of the third stream with a polar compound; stream after the mixing in an absorber; separating the vapor and liquid of the third stream after the mixing in an absorber; absorbing the remaining unabsorbed carbon dioxide in a lean portion of the polar compound in the absorber, the absorber carbon dioxide and ethane with the ...
1989-08-29
The characteristics of surface oxidation and corrosion resistance of nitrogen implanted zircaloy-4
International Nuclear Information System (INIS)
This work is concerned with the development and application of ion implantation techniques for improving the corrosion resistance of zircaloy-4. The corrosion resistance in nitrogen implanted zircaloy-4 under a 120 keV nitrogen ion beam at an ion dose of 3 x 10"1"7 cm"-"2 depends on the implantation temperature. The characteristics of surface oxidation and corrosion resistance were analyzed with the change of implantation temperature. It is shown that as implantation temperature rises from 100 to 724 C, the colour of specimen surface changes from its original colour to light yellow at 100 C, golden at 175 C, pink at 300 C, blue at 440 C and dark blue at 550 C. As the implantation temperature goes above 640 C, the colour of surface changes to light black, and the surface becomes a little rough. The corrosion resistance of zircaloy-4 implanted with nitrogen is sensitive to the implantation temperature. The pitting potential of specimens increases from 176 to 900 mV ...
Energy Technology Data Exchange (ETDEWEB)
The processes of lung growth, injury, and repair are characterized by alterations in fibroblast synthesis and interstitial distribution of extracellular matrix components. Transforming growth factor beta (TGF-beta), which is postulated to play a role in modulating lung repair, alters the distribution of several matrix components such as collagen and fibronectin. We studied the effect of TGF-beta on the synthesis and distribution of the various glycosaminoglycans (GAGs) and whether these effects may explain its role in lung repair. Human diploid lung fibroblasts (IMR-90) were exposed to various concentrations of TGF-beta (0-5 nM) for variable periods of time (0-18 h). Newly synthesized GAGs were labeled with either (3H)glucosamine or (35S)sulfate. Individual GAGs were separated by size exclusion chromatography after serial enzymatic and chemical digestions and quantitated using scintillation counting. There was a ...
1990-09-01
Shock absorber for the leg structure of offshore jack-up rig
Energy Technology Data Exchange (ETDEWEB)
A shock absorber mechanism and method for use on the leg structure of a jack-up offshore drilling rig is described. It is mounted on the bottom of each existing leg of a drilling rig and comprises a pointed piston member which is positioned on the bottom of the leg structure and projects downwards through the can/footing of the rig leg. The piston member is held in place by a resilient tension member which is designed to absorb shock forces during vertical/axial impact of the leg structure when contact is made with the ocean floor. (author).
1992-02-19
Application properties of AB{sub 2}-type hydrogen absorbing alloys
Energy Technology Data Exchange (ETDEWEB)
Use of hydrogen absorbing alloys in various practical applications is always connected with the problem of production of starting alloys. The transition from laboratory samples to small-scale production involves the change of furnace and its operation mode and this has an effect on the preparation method of mixture of starting metal. Also, for some applications such as thermosorption compressors the exact values of thermodynamical parameters of reaction are needed. In the present work we present the results of investigation of series Laves phase hydrogen-absorbing alloys which can be promising in for use in different devices. 1 ref.
1998-07-01
International Nuclear Information System (INIS)
Full text: Thermoluminescence (TL) is a phenomenon of light emission caused by heating a pre-irradiated material. When ionizing radiation hits a TL material, electrons are freed from some atoms and moved in the material, leaving behind 'holes' of positive charge. Subsequently when the TL material is heated, the electrons and the 'holes' re-combine, and release the extra energy in the form of light. The light intensity can be measured, and related to the amount of energy initially absorbed through exposure to the ionizing radiation. In nineteen sixties thermoluminescence dosimeters (TLD) became popular for dosimetric applications in view of their small size, sensitivity and accuracy. Consequently, in early seventies, several countries started adopting of TLD for personnel monitoring. The idea of introducing TLD to replace the then prevalent film dosimeter for personnel monitoring in India was mooted and successfully implemented by Dr. K G Vohra. Limitations of ...
Target stations and beam dumps for the CERN SPS
International Nuclear Information System (INIS)
The design of the absorber blocks for internal and external dumping of the SPS proton beam is discussed. In addition, the external target stations for slow and fast extracted proton beams are described.
1977-03-16
Semiactive field-controllable magneto-rheological fluid dampers for mountain bicycles
This paper presents the development and evaluation of field- controllable, semi-active magneto-rheological fluid (MRF) shock absorbers for a mountain bicycle. Recent trends in the bicycle industry show a movement towards semi-active suspension systems. Two new MRF dampers are designed and tested with the intent of being used on the front and rear suspension of a modern mountain bicycle. The MRF shock absorbers are designed to emulate the performance of the original equipment manufacturer shock absorbers in passive mode. Application of an input electric current to the MRF shock absorber causes a dramatic increase in the damping capacity. Procedures and results are presented for the design and experimental characterization of these MRF dampers.
2000-06-01
Root Cause Analysis, Tank Fire Problem, M1A1 Main Battle ...
... ammunition is stored. Combustible cartridge cases could absorb moisture, swell, and not chamber properly. Additionally, moisture ...
1989-02-01
Power efficiency for very high temperature solar thermal cavity receivers
This invention is an improved solar energy cavity receiver for exposing materials and components to high temperatures. The receiver includes a housing having an internal reflective surface defining a cavity and having an inlet for admitting solar radiation thereto. A photothermal absorber is positioned in the cavity to receive radiation from the inlet. A reflective baffle is positioned between the absorber and the inlet to severely restrict the re-radiation of energy through the inlet. The front surface of the baffle defines a narrow annulus with the internal reflective surface of the housing. The front surface of the baffle is contoured to reflect incoming radiation onto the internal surface of the housing, from which it is reflected through the annulus and onto the front surface of the absorber. The back surface of the baffle intercepts infrared radiation from the front of the absorber. With this ...
1984-01-01
Power efficiency for very high temperature solar thermal cavity receivers
Energy Technology Data Exchange (ETDEWEB)
This invention is an improved solar energy cavity receiver for exposing materials and components to high temperatures. The receiver includes a housing having an internal reflective surface defining a cavity and having an inlet for admitting solar radiation thereto. A photothermal absorber is positioned in the cavity to receive radiation from the inlet. A reflective baffle is positioned between the absorber and the inlet to severely restrict the re-radiation of energy through the inlet. The front surface of the baffle defines a narrow annulus with the internal reflective surface of the housing. The front surface of the baffle is contoured to reflect incoming radiation onto the internal surface of the housing, from which it is reflected through the annulus and onto the front surface of the absorber. The back surface of the baffle intercepts infrared radiation from the front of the absorber. With this ...
1984-10-30
Energy Technology Data Exchange (ETDEWEB)
An emergency shutdown system for high-temperature gas-cooled pebble-bed reactors is proposed in addition to the common absorber rod shutdown system. This system is based on the strongly absorbing effect of small boronated graphite spheres (called KLAK), which trickle in case of emergency by gravity from the top reflector into the reactor core. The inner reflector of the Siemens-Argonaut reactor was substituted by an assembly of spherical Arbeitsgemeinschaft Versuchsreaktor fuel elements, and the shutdown effect was examined by installing well-defined KLAK nests inside this assembly. The purpose was to develop and prove a calculational procedure for determining criticality values for assemblies of large fuel spheres and small absorbing spheres.
1987-09-01
Influence of absorbed hydrogen on the positron lifetime spectra in Pd, Pd-Ag, Pd-Cu
International Nuclear Information System (INIS)
(1 Oct 1979). German Democratic Republic Alekseeva, OK Onishchuk, VA
1979-10-01
Improved power efficiency for very-high-temperature solar-thermal-cavity receivers
Energy Technology Data Exchange (ETDEWEB)
This invention is an improved solar energy cavity receiver for exposing materials and components to high temperatures. The receiver includes a housing having an internal reflective surface defining a cavity and having an inlet for admitting solar radiation thereto. A photothermal absorber is positiond in the cavity to receive radiation from the inlet. A reflective baffle is positioned between the absorber and the inlet to severely restrict the re-radiation of energy through the inlet. The front surface of the baffle defines a narrow annulus with the internal reflective surface of the housing. The front surface of the baffle is contoured to reflect incoming radiation onto the internal surface of the housing, from which it is reflected through the annulus and onto the front surface of the absorber. The back surface of the baffle intercepts radiation from the front of the absorber. With this arrangement, a ...
1982-04-14
British Library Electronic Table of Contents (United Kingdom)
Abstract The characteristics of desulfurization and denitrification with composite absorbent were researched through aqueous absorption experiments. The removal efficiencies of SO2 and NO were up to 100 and 95%, respectively. The composite absorbent included NaClO2 and component M. Existence of component M in the solution could reduce the absorbent cost compared with using sodium chlorite alone. Chlorine dioxide, as main reaction intermediate product, participated in oxidation reaction. The optimal experimental conditions involved NaClO2 concentration of1.13 mmol/L, solution pH of 5.5, molar ratio (M/NaClO2) of 4.1, reaction temperature of 323 K. The optimal solution pH and reaction temperature were both in the required ranges of limestone-gypsum wet flue gas desulfurization (FGD) process....
2011-01-01
Energy absorbers used against impact loading
International Nuclear Information System (INIS)
In the WWER-440 reactor the primary piping consists of six horizontal loops going radially from the pressure vessel, each loop having a horizontal steam generator. In this reactor type the relatively long primary piping with many curved sections requires special attention in order to successfully eliminate the consequences of the design basis accident. Emergency supports are located in appropriate places to restrict the movements of the pipe. Under normal conditions there is a gap of some centimeters between the pipe and a support so that in the pipe can be deformed freely under changing loads. This paper deals with those energy-absorbing structures used at the Loviisa Nuclear Power Plant for protection against impact loading. Places and circumstances where energy-absorbing structures are employed are specified. Development and design of impact absorber elements are discussed and impact tests are described. (Auth.).
1975-09-08
International Nuclear Information System (INIS)
The behaviour of the packaging materials under radiation field has a great importance in radiation processing, because, in most cases, they are finally responsible for the preservation of the beneficent changes achieved in irradiated products. For example, in radiation sterilisation and food irradiation, the packages must preserve the sterilisation, respectively the sanitisation. They must preserve also the physical barrier feature. The radiation effects on plastics were extensively studied in the last decades for nuclear industry and more recently for radiation processing. The two major effects of nuclear radiation on polymeric materials are the degradation and cross-linking. The degradation consists in breaking of macromolecules after interaction with nuclear particles, amplified by the free radicals which persist long periods, especially in crystalline polymers. Oxygen could penetrate the sample and interact with free radicals so that the degradation process continues after the ...
Metabolic fate of chlorinated paraffins
Energy Technology Data Exchange (ETDEWEB)
The disposition of three (1-/sup 14/C)-chlorododecanes (MCDD, PCDD I and PCDD II; 17.4%, 55.9%, and 68.5% chlorination) was studied in C57Bl mice. (1-/sup 14/C)-lauric acid (LA) was studied as reference compound. Fifty-two percent (MCDD), 32% (PCDD I), and 8% (PCDD II) of the radioactive doses were exhaled as /sup 14/CO/sub 2/ during 12 h after i.v. injection. Similar results were obtained after p.o. administration. In addition to a marked labelling of the liver and fat, the distribution patterns observed at 24 h after administration revealed an uptake of radioactivity in tissues with high cell turnover/high metabolic activity, e.g., intestinal mucosa, bone marrow, salivary glands and thymus. The concentration of radioactivity in these sites and the exhalation of /sup 14/CO/sub 2/, which were inverse to the degree of chlorination, indicate that the chloroalkanes are degraded to metabolites which can be utilized in the intermediary metabolism. A ...
1982-09-01
Indoor radon dose assessment for Osijek
Energy Technology Data Exchange (ETDEWEB)
After ten years' investigation of radon's seasonal variation at three very different locations, as well as radon concentration measurements in kindergartens, schools, air-raid shelters and cellars, systematic indoor radon measurements were undertaken in dwellings (residential buildings) of Osijek (East Croatia, 130andpuncsp; omitted000 citizens). Indoor radon was measured by means of the LR-115 SSNT detector at 48 town locations that gave an arithmetic mean of 71.6 Bq/m{sup 3}, standard deviation of 44.0 Bq/m{sup 3} and geometric mean of 60.1 Bq/m{sup 3}, for the radon concentration range from 22.7 to 185.6 Bq/m{sup 3}. Radon measurements, performed by the silicon Radhome detector, did not differ significantly. The empirical frequency distribution of radon concentrations, with the class width of 20 Bq/m{sup 3}, was in accordance with the theoretical log-normal distribution which was shown with the {chi}{sup 2}-test. The radon ...
1999-05-01
International Nuclear Information System (INIS)
Environmental Survey Laboratory at Tarapur, Maharashtra site carries out environmental radioactivity measurements in different matrices to evaluate the impact of operating nuclear installations. In this paper, the evaluation of data of 1983-2007 (25 years) is presented. Time trends of particulate radioactivity, correlation between "1"3"7Cs in discharge canal seawater and station discharged activity and correlation of "1"3"7Cs, "6"0Co, and "1"3"1I in marine species like Sponge and Nerita and corresponding discharged activity were carried out. Statistical analysis of environmental data of seawater and marine fish for several radionuclides, for distributions, showed that the data best fits lognormal distribution. A strong correlation between "1"3"7Cs in seawater and "1"3"7Cs in liquid waste discharge was observed (R"2 = 0.8, P = 0.000). Similarly correlation was very good for Nerita and discharged concentration for "1"3"7Cs, "1"3"1I and "6"0Co ...
2008-07-16
Convolution/superposition using the Monte Carlo method
International Nuclear Information System (INIS)
The convolution/superposition calculations for radiotherapy dose distributions are traditionally performed by convolving polyenergetic energy deposition kernels with TERMA (total energy released per unit mass) precomputed in each voxel of the irradiated phantom. We propose an alternative method in which the TERMA calculation is replaced by random sampling of photon energy, direction and interaction point. Then, a direction is randomly sampled from the angular distribution of the monoenergetic kernel corresponding to the photon energy. The kernel ray is propagated across the phantom, and energy is deposited in each voxel traversed. An important advantage of the explicit sampling of energy is that spectral changes with depth are automatically accounted for. No spectral or kernel hardening corrections are needed. Furthermore, the continuous sampling of photon direction allows us to model sharp changes in fluence, such as those ...
2003-07-21
Energy Technology Data Exchange (ETDEWEB)
Silicon on insulator (SOI) structures are promising candidates for the fabrication of VLSI circuits with very high packing densities. The preparation of such structures can now be achieved by high dose implantation of reactive ion species such as oxygen to produce buried layers of SiO/sub 2/ in silicon. In this paper we report experiments to depth profile these layered structures by SIMS. SOI samples have been prepared by implanting (100) silicon wafers with 400 keV molecular oxygen ions at a dose of 1.8x10/sup 18/ O/sup +/ cm/sup -2/. During the implantation the wafers were maintained at temperatures between 325 and 600/sup 0/C, using beam heating, which achieved in situ-annealing and ensured that the top silicon layer remained single crystal. Analysis was carried out on an Atomika DIDA-II spectrometer using 10 keV Ar/sup +/ ions with a low current density of less than 1 mA cm/sup -2/. During analysis negative secondary ions were monitored ...
1983-12-15
Modeling marrow damage from response data: Morphallaxis from radiation biology to benzene toxicity
Energy Technology Data Exchange (ETDEWEB)
Consensus principles from radiation biology were used to describe a generic set of nonlinear, first-order differential equations for modeling of toxicity-induced compensatory cell kinetics in terms of sublethal injury, repair, direct killing, killing of cells with unrepaired sublethal injury, and repopulation. This cellular model was linked to a probit model of hematopoietic mortality that describes death from infection and/or hemorrhage between {approximately} 5 and 30 days. Mortality data from 27 experiments with 851 doseresponse groups, in which doses were protracted by rate and/or fractionation, were used to simultaneously estimate all rate constants by maximum-likelihood methods. Data used represented 18,940 test animals distributed according to: (mice, 12,827); (rats, 2,925); (sheep, 1,676); (swine, 829); (dogs, 479); and (burros, 204). Although a long-term, repopulating hematopoietic stem cell is ancestral to all lineages needed to ...
1995-12-01
Concept of malignant significant factor and its applicability for and occupational exposures
International Nuclear Information System (INIS)
In the medical and occupational exposures, there is a tradition to use the genetically significant dose as an index of harm to the population although it only includes the genetical effects from ionizing radiations. A similar significant dose for somatic effects such as radiation leukemogenesis and carcinogenesis should be added to the genetically significant dose in order to approach an index of total harm to the population from medical and occupational exposures. For this purpose, leukemia and malignant significant factors were determined based on the induction of malignant diseases including leukemia for the atomic bombs in Hiroshima and Nagasaki and the life expectancy of individuals subject to medical examinations or treatments as well as radiation workers, taking account of the possibility of their deaths due to other diseases or accidents during a latent period of malignant diseases. The resultant significant factors ...
1980-01-01
A campaign of discrete radon concentration measurements in soil of Niska Banja town, Serbia
Energy Technology Data Exchange (ETDEWEB)
The first radon soil gas survey in Serbia, using passive detectors (SSNTD, CR-39), was carried out in June 2005 at field sites in Niska Banja town. The aim of the survey was to identify risk zones characterised by high levels of this radioactive gas. Radon measurements were made at the depth of 50 cm, in the ground according to a systematic grid pattern. Furthermore, at all 48 measurement points, the surface gamma dose rates in the air was also measured at the same locations and soil samples were collected for gamma spectrometric analysis for the radionuclides {sup 226}Ra, {sup 228}Th and {sup 40}K. Radon concentrations were found to range from 1270 to 155000Bqm{sup -3} with an average of 33765Bqm{sup -3} and a median value of 12626Bqm{sup -3}. The geometrical mean value and geometrical standard deviation were calculated as 16160Bqm{sup -3} and 3.5Bqm{sup -3}, respectively. Gamma dose rate varies from 92 to 316nGyh{sup -1}, with an average of ...
2007-11-15
A campaign of discrete radon concentration measurements in soil of Niska Banja town, Serbia
International Nuclear Information System (INIS)
The first radon soil gas survey in Serbia, using passive detectors (SSNTD, CR-39), was carried out in June 2005 at field sites in Niska Banja town. The aim of the survey was to identify risk zones characterised by high levels of this radioactive gas. Radon measurements were made at the depth of 50 cm, in the ground according to a systematic grid pattern. Furthermore, at all 48 measurement points, the surface gamma dose rates in the air was also measured at the same locations and soil samples were collected for gamma spectrometric analysis for the radionuclides "2"2"6Ra, "2"2"8Th and "4"0K. Radon concentrations were found to range from 1270 to 155000Bqm"-"3 with an average of 33765Bqm"-"3 and a median value of 12626Bqm"-"3. The geometrical mean value and geometrical standard deviation were calculated as 16160Bqm"-"3 and 3.5Bqm"-"3, respectively. Gamma dose rate varies from 92 to 316nGyh"-"1, with an average of 132nGyh"-"1. The radium content in ...
2007-11-01
Energy Technology Data Exchange (ETDEWEB)
This paper reports the estimates concerning the atmospheric carbon dioxide absorption and storage by living plants all over the world. It is necessary to decrease atmospheric carbon dioxide concentrations for avoiding global warming. As living plants absorb carbon dioxide by photosynthesis and accumulate carbon in their bodies, they can play an important role to remove atmospheric carbon dioxide. Literatures describing distribution areas, biomass values and net primary productivity (NPP) of forests, marine plants and microorganisms were collected. Examining those data, the biomass and NPP of forests, marine plants and microorganisms can be summarized as follows: (1) Forest biomass and their NPP of the world. The world's forest area is recently estimated as 4 billion hectares, and their biomass is about 400 billion tons of carbon which is equal to 2/3 of the total atmospheric carbon. The NPP of the world's forest is estimated ...
1992-01-01
Formation of the natural sulfate aerosol
Energy Technology Data Exchange (ETDEWEB)
Anthropogenic sulfate aerosol, together with particles from biomass burning, may significantly reduce the climatic warming due to man-made greenhouse gases. The radiative forcing of aerosol particles is based on their ability to scatter and absorb solar radiation (direct effect), and on their influences on cloud albedos and lifetimes (indirect effect). The direct aerosol effect depends strongly on the size, number and chemical composition of particles, being greatest for particles of 0.1-1 {mu}m in diameter. The indirect aerosol effect is dictated by the number of particles being able to act as cloud condensation nuclei (CCN). For sulfate particles, the minimum CCN size in tropospheric clouds is of the order of 0.05-0.2 {mu}m. To improve aerosol parameterizations in future climate models, it is required that (1) both primary and secondary sources of various particle types will be characterized at a greater accuracy, and (2) the influences of various atmospheric ...
1996-12-31
Carbon dioxide absorption with aqueous potassium carbonate promoted by piperazine
Energy Technology Data Exchange (ETDEWEB)
Many commercial processes for the removal of carbon dioxide from high-pressure gases use aqueous potassium carbonate systems promoted by secondary amines. This paper presents thermodynamic and kinetic data for aqueous potassium carbonate promoted by piperazine. Research has been performed at typical absorber conditions for the removal of CO{sub 2} from flue gas. Piperazine, used as an additive in 20-30 wt% potassium carbonate, was investigated in a wetted-wall column using a concentration of 0.6 m at 40-80{sup o}C. The addition of 0.6 m piperazine to a 20 wt% potassium carbonate system decreases the CO{sub 2} equilibrium partial pressure by approximately 85% at intermediate CO{sub 2} loading. The distribution of piperazine species in the solution was determined by proton NMR. Using the speciation data and relevant equilibrium constants, a model was developed to predict system speciation and equilibrium. The addition of 0.6 m piperazine to 20 ...
2004-09-01
Examples are used to demonstrate that a shift in the point of emphasis is necessary with regard to radiation hazard in medicinal X-ray diagnosis. The parameters employed in this study to calculate somatic dose (SD) and somatically significant dose (SSD) m...
1980-01-01
Radiation dose in computerized tomography
International Nuclear Information System (INIS)
Dosimetric studies in 80 patients examined with the tomographic device 'Somatom' are reported. The gonad doses are compared to those of conventional radiographic techniques.
Indoor radon concentration measurements in Tarqumia Girl Schools at Western Hebron Region, Palestine
International Nuclear Information System (INIS)
In this study, radon-222 in indoor air was surveyed in 62 rooms located in four governmental schools, for girls, in Tarqumia town that lies in the north western part of Hebron city in Palestine. The annual effective dose equivalents resulting from the inhalation of radon and its daughters by 2318 pupils and 102 staff members occupying the surveyed rooms were also measured. TASTRAK, a solid state nuclear track detector, has been used to measure the indoor radon concentrations at those schools thus, 124 radon detectors were distributed in the four school buildings. The radon detectors stayed for 70 days between February 2006 and April 2006. The results showed that the radon concentration and the annual effective dose equivalent in these schools were varied from 12 to 232.5 Bq/m"3 with an average of 34.1 Bq/m"3 and 0.62 to 12.0 mSv/y with an average of 1.76 mSv/y, respectively. The mean values of radon concentrations in ...
Energy Technology Data Exchange (ETDEWEB)
The measuring series was performed from November 1991 through April 1992 in seven drinking-water conditioning plants of the Fichtel mountains area in the north-eastern part of Bavaria, and the results revealed as an annual average a dose of about 1 - 40 WLM. The area of interest is a drinking-water catchment area where the ground water and other water resources include waters particularly rich in radon content, which explains this relatively high dose range. This is why comprehensive, specific local and long-term mearurements were carried out in order to assess the occupational radiation dose in the drinking-water conditioning plants, taking as a model site the conditioning plant of the municipal utilities of Hof in Weissenstadt. These more specific measurements were performed by the Technical Inspectorates (TUeV) of Bavaria and Saxony and the isotope laboratory of Georg-August University of Goettingen in mid-April 1994 ...
1995-03-01
The malignancy significant dose from external beam radiotherapy
International Nuclear Information System (INIS)
In the present study an estimate is made of the malignancy significant dose from external beam radiotherapy in New Zealand utilizing data obtained in a survey conducted in 1975. This survey had been designed to assess genetically significant dose. A weighted effective dose equivalent is derived from the malignancy significant dose for direct comparison with mean per capita effective dose equivalents arising from other sources of radiation. 14 refs., 1 fig., 8 tabs.
1987-01-01
Further means for reducing radiation dose during exposure of the pelvis in infants
International Nuclear Information System (INIS)
A simple dose-saving procedure for the diagnosis of congenital hip dysplasia employing a diaphragm in nearfocus position is presented. Doses to the skin and the gonads were measured with a phantom for the new and other techniques. With optimal techniques the skin dose is smaller than 2 mR and the gonadal doses lie around 0.1 mR for both male and female patients. An estimate of the dose burden from undesired radiation is appended. (orig.).
Fishes of Georgia: Georgia Freshwater Fish Distribution, Classification, and Information
Georgia Fish: Freshwater fish distributions,classification, conservation status, and distribution comments for Georgia....
International Nuclear Information System (INIS)
The use of absorbable polyglactin 910 mesh (Vicryl) is described in a case of Ewing's sarcoma of the pelvis. An operation was performed to hold the small bowel and colon out of the pelvis for a temporary period during which radical radiotherapy was delivered. The mesh allowed the temporary displacement of bowel and obviated bowel radiation morbidity. (author).
Thermal performance of solar air collectors with a passive heat transfer augmentation technique
Energy Technology Data Exchange (ETDEWEB)
One of the main disadvantages of solar air collectors in practical applications is their relatively low efficiency. In this experimental investigation, the shape and arrangement of absorber surfaces of the collectors were reorganized to provide better heat transfer surfaces suitable for the passive heat transfer augmentation techniques. The performance of such solar air collectors with staggered absorber sheets was tested. The experimental results show that it is possible to provide 10 to 25% enhancement in the efficiency compared to the conventional solar air collectors. (authors)
2000-07-01
The trick with the heat pump; Der Trick mit der Waermepumpe
Energy Technology Data Exchange (ETDEWEB)
The brochure reports on the construction and method of operation of heat pumps: - Efficiency and temperature difference - output figure - circuit processes - saving of primary energy - monovalent and bivalent plants - absorber, earth collectors - heat recovery. (HW) [Deutsch] Die Broschuere berichtet ueber den Aufbau und die Wirkungsweise von Waermepumpen: - Wirkungsgrad und Temperaturdifferenz - Leistungszahl - Kreisprozesse - Einsparung von Primaerenergie - monovalente und bivalente Anlagen - Absorber, Erdkollektoren - Waermerueckgewinnung. (HW)
1997-12-31
Investigation of carbon dioxide absorption by absorbents impregnated with alkanol amines
Energy Technology Data Exchange (ETDEWEB)
In studying the absorption of carbon dioxide by absorbents impregnated with alkanol amines, researchers used a laboratory-scale packed column to determine the overall gas-phase mass-transfer coefficients and enhancement factors. A model derived for the mechanism of the chemical reaction taking place in the interfacial layer accounts for the effect of the reaction upon the absorption rate better than other models.
1981-01-01
Heat exchange in a multi-cavity volumetric solar receiver
Energy Technology Data Exchange (ETDEWEB)
The concept of a multi-cavity volumetric solar receiver is very attractive for the profitability of certain of its characteristics such as high efficiency and economy. The absorber is based on a pack of small ceramic cavities which intercept and absorb the inherent high solar flux reflected from an array of mirrors. Atmospheric air acts as a coolant medium when it is drawn through the pack. A model for an overall heat transfer performance of the receiver is given and numerically solved.
1991-01-01
Effect of electron irradiation on domain wall pinning defects in 50-50 NiFe
International Nuclear Information System (INIS)
A magnetic measuring technique, which sorts out defects according to a distribution function n, was used to study the influence of electron irradiation on 50-50 NiFe. The distribution function is determined in terms of the maximum force f/subm/ that a defect can exert on a forward moving domain wall, or equivalently, the range z_0, which is the distance the mean position of the wall may move past the defect before the wall snaps free from the pinning action of the defect. The range and maximum force are related by a spring constant k, viz., f/subm/=kz_0. The quantity n (z_0) dz_0 gives the number of defects per unit volume having a range between z_0 and z_0+dz_0. Distribution functions were determined before and after electron irradiation. The irradiation was for 100 min with 18-MeV electrons with a dose of 1.1times10"1"7 e/cm"2. Following irradiation, there was a substantial decrease in the number of ...
International Nuclear Information System (INIS)
The DNA double-strand break (DSB) damage response induced by high energy charged particles on lung fibroblast cells embedded in a 3-dimensional (3-D) collagen tissue equivalents was investigated using antibodies to the DNA damage response proteins gamma-histone 2AX (#gamma#-H2AX) and phosphorylated DNA-PKcs (p-DNA-PKcs). 3-D tissue equivalents were irradiated in positions across the linear distribution of the Bragg curve profiles of 307.7 MeV/nucleon, 556.9 MeV/nucleon, or 967.0 MeV/nucleon "5"6Fe ions at a dose of 0.30 Gy. Patterns of discrete DNA damage streaks across nuclei or saturated nuclear damage were observed, with saturated nuclear damage being more predominant as samples were positioned closer to the physical Bragg peak. Quantification of the DNA damage signal intensities at each distance for each of the examined energies revealed a biological Bragg curve profile with a pattern of DNA damage intensity similar to the physical Bragg ...
2010-03-01
Development of barcode system for internal dose monitoring
International Nuclear Information System (INIS)
In Tarapur Atomic Power Station unit-3 and 4, which is 540 MWe pressurized heavy water reactor, tritium is produced in primary heat transport system and moderator system. Tritium is a major contributor to the internal dose. Internal dose contributes about 30% of the collective dose. Internal dose monitoring and its control are important to control the collective dose. Estimation of internal dose is done by analysis of bioassay samples of radiation workers. In a month, about 7000 bioassay samples are analysed for the internal dose assessment during normal operation, and about 12000 during the biennial shut down of the reactor. To enhance the sample preparation and counting performance, minimize the entry errors and reduce the processing time, barcode based label generation system was developed for the internal dose ...
2008-11-19
Energy Technology Data Exchange (ETDEWEB)
Radiation therapy has had a significant and an expanded role in the management of cancer of the pancreas during the last decade. In particular, for locally advanced disease, radiation therapy has improved the median survival of patients to 1 year. Intraoperative electron beam therapy has been applied to unresectable and resectable pancreatic cancer in an attempt to enhance local control of disease and to improve patient survival. This paper presents a survey of the role of radiation therapy in treatment of cancer of the pancreas, provides information on the radiobiological aspects of this treatment modality and details the physical and dosimetric characteristics of intraoperative radiation therapy with electrons. Presented are the design specifics of an applicator system, central axis beam data, applicator parameters, dose distribution data, shielding, treatment planning and means of verification. Emphasis is placed on the collaboration and ...
1989-01-01
International Nuclear Information System (INIS)
Radiation therapy has had a significant and an expanded role in the management of cancer of the pancreas during the last decade. In particular, for locally advanced disease, radiation therapy has improved the median survival of patients to 1 year. Intraoperative electron beam therapy has been applied to unresectable and resectable pancreatic cancer in an attempt to enhance local control of disease and to improve patient survival. This paper presents a survey of the role of radiation therapy in treatment of cancer of the pancreas, provides information on the radiobiological aspects of this treatment modality and details the physical and dosimetric characteristics of intraoperative radiation therapy with electrons. Presented are the design specifics of an applicator system, central axis beam data, applicator parameters, dose distribution data, shielding, treatment planning and means of verification. Emphasis is placed on the collaboration and ...
International Nuclear Information System (INIS)
Non-destructive methods of diagnosis for detecting cable degradation by aging are being studied recently for improvement of electric wires and cables. This study examines degradation behaviors of cable sheath and insulation by combined accelerated aging tests applying thermal and radiation stresses simultaneously using a typical low voltage cable. According to experiments, elongation of cross-linked polyethylene insulation deteriorated at a faster rate than PVC sheath did under low doses below 50 Gy/h. Therefore, measurements using a time domain dielectric spectrometer (TDS) were carried out for the purpose of developing a method of degradation diagnosis of insulation. It was found that values of tan#delta# measured at very low frequencies below 0.1 Hz increase in pace with degradation of insulation reflecting the level of degradation more effectively than those measured at frequencies around the commercial frequency. In order to consider causes of the increases of ...
2000-05-01
Energy Technology Data Exchange (ETDEWEB)
The radioiodine-labeled amines currently available as brain-imaging agents, based on our previous work and that of others, are prepared either by exchange labeling or by direct iodination of a protected intermediate. The intrinsic slowness of these processes limits their potential for use with the positron-emitting 122I, as it has a half-life of only 3.6 min. This isotope has advantages of a low dose to the patient and availability from a generator containing the parent 20-h 122Xe. To develop a radiopharmaceutical in which 122I could be utilized, we prepared a number of secondary and tertiary amines (maintaining the 2,5-dimethoxy substitution pattern which allows direct iodination at the 4-position) with 131I. The organ distributions of these compounds were studied, and the best properties were found in the N,N-dimethyl homologue (2,5-dimethoxy-N,N-dimethyl-4-iodoamphetamine). This compound was successfully synthesized in a matter of seconds, ...
1984-08-01
International Nuclear Information System (INIS)
The radioiodine-labeled amines currently available as brain-imaging agents, based on our previous work and that of others, are prepared either by exchange labeling or by direct iodination of a protected intermediate. The intrinsic slowness of these processes limits their potential for use with the positron-emitting 122I, as it has a half-life of only 3.6 min. This isotope has advantages of a low dose to the patient and availability from a generator containing the parent 20-h 122Xe. To develop a radiopharmaceutical in which 122I could be utilized, we prepared a number of secondary and tertiary amines (maintaining the 2,5-dimethoxy substitution pattern which allows direct iodination at the 4-position) with 131I. The organ distributions of these compounds were studied, and the best properties were found in the N,N-dimethyl homologue (2,5-dimethoxy-N,N-dimethyl-4-iodoamphetamine). This compound was successfully synthesized in a matter of seconds, ...
Quality Management for Neutron Transmutation Doping of Silicon Ingot in HANARO
Energy Technology Data Exchange (ETDEWEB)
By using this doping method, silicon semiconductors with extremely uniform dopant distributions can be produced, and this is the dominant advantage of NTD compared with a conventional chemical doping. Good uniformity of a dopant concentration is usually required for high power applications such as thyristor (SCR), IGBT, IGCT and GTO and for special sensors. Achieving an accurate neutron fluence corresponding to a target resistivity as well as a uniform irradiation is the prime target of a neutron irradiation for NTD. Generally, in order to reach an accurate neutron fluence, a real time neutron flux is monitored by a neutron detector such as a Self-powered Neutron Detector(SPND). And, after an irradiation, the total irradiation fluence is confirmed by measuring the absolute activity of a neutron activation sample that has been irradiated with a silicon ingot, and thus the SPND can be properly calibrated. Excellent irradiation uniformity and a high accuracy for a ...
2007-10-15
Kinetics of self-interstitial cluster aggregation near dislocations and their influence on hardening
International Nuclear Information System (INIS)
Kinetic Monte Carlo (KMC) computer simulations are performed to determine the kinetics of SIA cluster 'clouds' in the vicinity of edge dislocations. The simulations include elastic interactions amongst SIA clusters, and between clusters and dislocations. Results of KMC simulations that describe the formation of 'SIA clouds' during neutron irradiation of bcc Fe and the corresponding evolution kinetics are presented, and the size and spatial distribution of SIA clusters in the cloud region are studied for a variety of neutron displacement damage dose levels. We then investigate the collective spatio-temporal dynamics of SIA clusters in the presence of internal elastic fields generated by static and mobile dislocations. The main features of the investigations are: (1) determination of the kinetics and spatial extent of defect clouds near static dislocations; (2) assessment of the influence of localized patches of SIA clouds on the ...
2009-08-01
Energy Technology Data Exchange (ETDEWEB)
Individual monitoring of personal exposure to inhalation of uranium oxides throughout the manufacture of fuel for pressurized water reactor (PWR) includes lung gamma-spectrometry, fecal analysis and urine analysis. Examination of the results shows the following: internal exposure is the consequence of repeated intake incidents as revealed by early peaks of urinary and particularly fecal elimination; a shift is often observed with the results of aerosol concentration measured through air collectors; the measured variations of uranium lung incorporations are relatively fast (apparent mean period 165 d). Correct evaluation of the effective dose equivalent from inhalation requires further information concerning the aerosol size distribution at work stations, the physico-chemical characteristics of the product leading to an estimate of its actual biological solubility, and the measurement of the fraction of aerosol liable to intake with an ...
1989-01-01
Hydrogen behavior in the iron surface layer modified by plasma nitriding and ion boronising
Energy Technology Data Exchange (ETDEWEB)
The effects of the plasma nitriding with the formation of compound nitride and diffusion zones and of the boronising with the different ion doses on hydrogen distribution and hydrogen induced deterioration of a surface layer were examined in the case of Armco iron. Electrochemical studies of hydrogen permeation rate, hydrogen vacuum extraction measurements, optical and scanning microscopy, X-ray diffraction and elastic recoil detection analysis (ERDA) were used. Accumulation of entering hydrogen within the various constituent zones of the modified layer inhibits the hydrogen transport into the metal and thus, decreases the mean hydrogen content in the deeper zones and in the core. Hydrogen accumulation within the compact nitride zone causes the expansion of the nitride lattice, nitride phase transformation and deterioration. The ion boronising enhances the hydrogen effects in the plasma nitrided layers. Therefore, modification of the surface ...
2000-12-01
Effects of interstitial clustering on transient enhanced diffusion of boron in silicon
Energy Technology Data Exchange (ETDEWEB)
A simulation model for boron diffusion which takes into account the aggregation of the excess interstitials in clusters, and subsequently, the dissolution of these defects, is proposed. The interstitial supersaturation and generation rate are determined according to the classical theory of nucleation and growth of particles, in analogy with the precipitation of a new phase in heavily doped silicon. The clusters are considered as precipitates formed by interstitial Si atoms. The B diffusion is modelled on the basis of the dopant-interstitial pair diffusion mechanism. The clusters dissolution during annealing maintains nearly constant, for a long period, the interstitial supersaturation and the related enhancement of the boron diffusion. This gives a good account of the diffusion results over a large range of experimental conditions. Furthermore, this approach describes most of the behavior of the transient enhanced diffusion (TED), like the temperature dependence of the level of the B ...
1997-11-01
Energy Technology Data Exchange (ETDEWEB)
Rats from an inbred Sprague-Dawley strain were fed semisynthetic diets with a low (0.3 energy percent (en %)), normal (3 en %) or high (10 en %) content of essential fatty acids (EFA) for at least three generations. Twenty-nine- to 33-day-old male rats were given a single intragastric dose of (1-14C)linoleic acid in olive oil, and the respiratory CO2, urine and feces were collected for 46 hours (expt 1) or 20 hours (expt 2). The 14C activity in respiratory CO2, feces, urine and the carcass was determined in both experiments. In experiment 2 it was also measured in samples of the brown fat, liver, adrenals, white fat, skeletal muscles and brain. In both experiments the rats fed the low EFA diet retained significantly more 14C activity than the rats fed the normal or high EFA diets. In all groups the concentration of label was highest in the brown fat and the adrenals, but the above differences among the groups with respect to 14C retention were mainly observed in ...
1984-09-01
Energy Technology Data Exchange (ETDEWEB)
Authors developed a C-arm type radiosurgery system of the linear accelerator suitable for stereotactic radiation therapy and a software for arranging 3-dimensional therapy in the system. In this system, the gantry far conical irradiation of 4 MV (0.6-3 Gy/min) and 6 MV (0.9-4.5 Gy/min) X ray or electron beam for the therapy was connected to a newly designed C-arm and was made capable of rotating around either of the axes crossing vertically. With this system, it became unnecessary to move the bed table of the patient for getting suitable distribution of radiation dose. The local accuracy which was measured by the CCD videocamera on the gantry, was within 0.5 mm from the radiation center. The system made it possible to shorten the irradiation time and to improve the local accuracy of irradiating site. The clinical trial was begun from June, 1996. (K.H.)
1996-10-01
International Nuclear Information System (INIS)
The fabrication and complete evaluation are described of a dihydropyridine in equilibrium pyridinium salt type redox system for the delivery of radioiodinated agents to the brain. The pivotal intermediate, N-succinimidyl (1-methylpyridinium iodide)-3-carboxylate was prepared by condensation of nicotinic acid and N-hydroxysuccinimide in the presence of dicyclohexylcarbodimide, followed by quaternization of III with methyl iodide. Tissue distribution studies of "1"2"5I-labeled 4-iodoaniline and the redox agents were performed in rats. ["1"2"5I]Iodoaniline initially showed moderate (0.58% dose/gm) brain uptake with subsequent release of the radioactivity from the brain. ["1"2"5I]Iodoaniline, when coupled to a dihydropyridine carrier showed higher uptake and retention in the brain. The ["1"2"5I]iodophenylethyl analogue showed uptake and retention in the brain to be very similar. Apparently the lipophilic agents cross the blood-brain barrier and are ...
Energy Technology Data Exchange (ETDEWEB)
Radiotherapy with high-energy carbon ion beams can be more advantageous compared to photons because of better physical dose distribution and higher biological efficiency in tumour cell sterilization. Despite enhanced normal tissue sparing, damage incurred by normal cells at the beam entrance is unavoidable and may affect the progeny of surviving cells in the form of inheritable cytogenetic alterations. Furthermore, the quality of the beam along the Bragg curve is modified by nuclear fragmentation of projectile and target nuclei in the body. We present an experimental approach based on the use of a polymethylmethacrylate (PMMA) phantom that allows the simultaneous exposure to a particle beam of several biological samples positioned at various depths along the beam path. The device was used to measure the biological effectiveness of a 60 MeV/amu carbon-ion beam at inducing chromosomal aberrations in G{sub 0}-human peripheral blood lymphocytes. ...
2007-06-15
Effective dose equivalent concept in radiopharmaceutical dosimetry
Energy Technology Data Exchange (ETDEWEB)
The Effective Dose Equivalent Concept defined by the International Commission on Radiological Protection in 1977 considers the risk from irradiation including both hereditary and somatic effects. This paper will deal with the definition of a concept for somatic effects only, the somatically significant dose equivalent. This is defined as the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by various individuals. The somatically effective dose equivalent for a particular radiopharmaceutical is the weighted sum of the average dose equivalent to various organs. The dose equivalent to various organs can be derived from an extended MIRD formalism also considering the rest of body excluding the source ...
1981-06-01
Effective dose equivalent concept in radiopharmaceutical dosimetry
International Nuclear Information System (INIS)
The Effective Dose Equivalent Concept defined by the International Commission on Radiological Protection in 1977 considers the risk from irradiation including both hereditary and somatic effects. This paper will deal with the definition of a concept for somatic effects only, the somatically significant dose equivalent. This is defined as the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by various individuals. The somatically effective dose equivalent for a particular radiopharmaceutical is the weighted sum of the average dose equivalent to various organs. The dose equivalent to various organs can be derived from an extended MIRD formalism also considering the rest of body excluding the source ...
Patient doses from medical uses of x-rays
International Nuclear Information System (INIS)
A survey to determine the annual genetically significant dose and mean bone-marrow dose to the Australian population from radiological procedures has been undertaken. For diagnostic radiology the following were carried out: determination of the frequency of a procedure; measurement of patient doses using TLD and processing of data and calculation of gonadal and bone-marrow doses.
1981-01-01
Evaluation of transient dose in conveyor type low dose irradiator
International Nuclear Information System (INIS)
In conveyor type irradiators, the movement of conveyor and the product boxes is not there until the source is fully in the irradiation position. In case the conveyor system fails the source must automatically be returned to its shielded storage vault. The dose received by the product during the movement of the source from or to the shield becomes significant if the total dose to be received by the product is small. A study has been carried out for evaluating the transient dose received by onions in the POTON irradiator. The results of the study are discussed in this paper. (author)
2003-03-05
Development of internal dose estimation software on radiation protection
International Nuclear Information System (INIS)
Objective: To develop a computerized method of internal dose estimation on radiation protection. Methods: Based on MIRD mathematic model of the organs and by means of the programming language of MS Visual Basic 6.0, a computer program of dose estimation in internal radiation was developed for radiation protection. Results: The computerized method of dose estimation for internal radiation was completed. Conclusions: This computerized method is very convenient for internal radiation dose estimation of several aspects. It can also be used in radiation accident. (authors)
2008-10-01
Treatment of prostatic cancer using daily intermittent multiportal therapy (DIMT) technique
Energy Technology Data Exchange (ETDEWEB)
In the treatment of prostatic cancer using a newly proposed intermittent multiportal therapy (DIMT), acute reactions, change in tumor marker levels, and complications more than 6 months after treatment were evaluated. From June 1989 to September 1990, 26 patients with prostatic cancer (stage A2, 3 patients; B, 9; C, 2; D, 10; recurrence, 2) were treated. Fifteen patients were followed up for more than one year, with a mean period of 11.6 months. The treatment schedule is 52.5 Gy in 16 fractions in 4 weeks for radical treatment, and 30.0 Gy in 8 fractions in 2 weeks for palliative treatment. The 360 degree rotation about the patient was divided into 16 fractions, and 2 opposing fractions were used in one day as parallel opposed portals to treat the target volume. The fractions were serially treated one per day, so that 8 treatment days produced a total dose of distribution similar to that for conventional conformational therapy. The size of the ...
1992-06-01
Collection of athermal phonons into doped Ge thermistors using quasiparticle trapping
Energy Technology Data Exchange (ETDEWEB)
We have developed a low-temperature particle detector that uses a novel quasiparticle trapping mechanism to funnel athermal phonon energy from an 80 mg Ge absorber into a 1.6 mg doped Ge thermistor via a superconducting Al film. We report on pulse height spectra obtained at 320 mK by scanning a {sup 241}Am alpha source along the device, and show that up to 20% of the energy deposited in the Ge absorber by a 5.5 MeV alpha particle interaction can be collected into a thermistor via quasiparticle trapping. We show that this device is sensitive to the position of an alpha particle interaction in the Ge absorber for interaction distances of up to 5 mm from a quasiparticle trap.
1995-05-15
Shielding options for the ITER conceptual design
Energy Technology Data Exchange (ETDEWEB)
Several shield options were analyzed for the ITER conceptual design to minimize the nuclear responses in the toroidal field (TF) coils. The total nuclear heating in the physics phase and the insulator dose in the technology phase are the most critical parameters in the design process. The first shield option has type 316 stainless steel and water shielding material. Steel and water also serve as structural material and coolant, respectively. The second option is similar to the first except that borated water is used instead of ordinary water. The other two options include a small layer of lead or boron carbide (B{sub 4}C) at the back of the shield. The last three shield options were considered to reduce the nuclear heating in the toroidal field coils relative to the steel/water shield. An optimization process was performed taking into consideration the thermal-hydraulics and the engineering requirements to define the shield configuration. A careful integration was ...
1989-10-01
International Nuclear Information System (INIS)
Diethyldithiocarbamate (DDTC), a chelating agent, is an active metabolite of disulfiram (Antabus) and is used in the rubber industry. The effect of DDTC on the tissue distribution of "2"0"3Pb was studied in rats. Two groups of rats were given an i.v. injection of 100 #mu#Ci "2"0"3Pb (28.6 nmol/kg b.wt.) as lead acetate. After 10 min one group received 2 mmol/kg b.wt. of DDTC as an i.p. injection. Rats were killed 4 and 72 h after injection of "2"0"3Pb and tissue concentration and excretion of "2"0"3Pb was determined by gamma counting. The brain concentration of "2"0"3Pb in DDTC-treated rats was nine times higher than in controls after 4 h and 14 times higher after 72 h. Treatment with DDTC also increased the lead concentration in fat about seven times at both survival intervals. On the other hand, uptake of "2"0"3Pb in bone was reduced by treatment with DDTC and at 4 h also kidney and blood had a lower concentration of "2"0"3Pb in DDTC-treated rats compared to ...
Radiation inactivation target size of rat adipocyte glucose transporter
Energy Technology Data Exchange (ETDEWEB)
In situ assembly states of rat adipocyte glucose transport protein in plasma membrane (PM) and in microsomal pool (MM) were assessed by measuring target size (TS) of D glucose-sensitive, cytochalasin B binding activity. High energy radiation inactivated the binding in both PM and MM by reducing the total capacity of the binding (B/sub T/) without affecting the dissociation constant (K/sub D/). The reduction in B/sub T/ as a function of radiation dose was analyzed based on classical target theory, from which TS was calculated. TS in the PM of insulin-treated adipocytes was 58 KDa. TS in the MM of noninsulin-treated and insulin-treated adipocytes were 112 and 109 KDa, respectively. With MM, however, inactivation data showed anomalously low radiation sensitivities at low radiation doses showing a shoulder in the semilog plots, which may be due to an interaction with a radiation sensitive inhibitor. With these results, they propose the following ...
1987-05-01
Physical mechanisms of transient enhanced dopant diffusion in ion-implanted silicon
Energy Technology Data Exchange (ETDEWEB)
Implanted B and P dopants in Si exhibit transient enhanced diffusion (TED) during annealing which arises from the excess interstitials generated by the implant. In order to study the mechanisms of TED, transmission electron microscopy measurements of implantation damage were combined with B diffusion experiments using doping marker structures grown by molecular-beam epitaxy (MBE). Damage from nonamorphizing Si implants at doses ranging from 5{times}10{sup 12} to 1{times}10{sup 14}/cm{sup 2} evolves into a distribution of {l_brace}311{r_brace} interstitial agglomerates during the initial annealing stages at 670{endash}815{degree}C. The excess interstitial concentration contained in these defects roughly equals the implanted ion dose, an observation that is corroborated by atomistic Monte Carlo simulations of implantation and annealing processes. The injection of interstitials from the damage region involves the dissolution ...
1997-05-01
Physical mechanisms of transient enhanced dopant diffusion in ion-implanted silicon
International Nuclear Information System (INIS)
Implanted B and P dopants in Si exhibit transient enhanced diffusion (TED) during annealing which arises from the excess interstitials generated by the implant. In order to study the mechanisms of TED, transmission electron microscopy measurements of implantation damage were combined with B diffusion experiments using doping marker structures grown by molecular-beam epitaxy (MBE). Damage from nonamorphizing Si implants at doses ranging from 5x10"1"2 to 1x10"1"4/cm"2 evolves into a distribution of #left brace#311#right brace# interstitial agglomerates during the initial annealing stages at 670 endash 815 degree C. The excess interstitial concentration contained in these defects roughly equals the implanted ion dose, an observation that is corroborated by atomistic Monte Carlo simulations of implantation and annealing processes. The injection of interstitials from the damage region involves the dissolution of #left ...
Energy Technology Data Exchange (ETDEWEB)
The radiation-induced microstructural changes have been studied by cross-sectional transmission electron microscopy for single-crystal {alpha}-Al{sub 2}O{sub 3} samples irradiated with triple ion beams (0.25 MeV H{sup +}, 0.6 MeV He{sup +} and 2.4 MeV O{sup 2+}; `Triple (A)`), (0.33 MeV H{sup +}, 0.45 MeV He{sup +} and 1.3 MeV O{sup +}; `Triple (B)`) and three consecutive single ion beams (0.3 MeV H{sup +} ion followed by 0.6 MeV He{sup +} and then 0.8 MeV O{sup +} ions) at 650 C to doses in the range 0.1-8.4 dpa at the damage peak. In the specimen irradiated with Triple (A), having the same average projected range to a total peak dose of 3.7 dpa, cavities with an average diameter of 13 nm were formed between 1.2 and 1.75 {mu}m in depth causing a swelling of 0.1% at the peak, which is larger than those of the specimens irradiated with other conditions. The extent of the cavity-introduced region is some 40% smaller than observed in the damage ...
1996-10-01
Microstructural evolution of single crystalline Al_2O_3 irradiated with single and triple ion beams
International Nuclear Information System (INIS)
The radiation-induced microstructural changes have been studied by cross-sectional transmission electron microscopy for single-crystal #alpha#-Al_2O_3 samples irradiated with triple ion beams (0.25 MeV H"+, 0.6 MeV He"+ and 2.4 MeV O"2"+; 'Triple (A)'), (0.33 MeV H"+, 0.45 MeV He"+ and 1.3 MeV O"+; 'Triple (B)') and three consecutive single ion beams (0.3 MeV H"+ ion followed by 0.6 MeV He"+ and then 0.8 MeV O"+ ions) at 650 C to doses in the range 0.1-8.4 dpa at the damage peak. In the specimen irradiated with Triple (A), having the same average projected range to a total peak dose of 3.7 dpa, cavities with an average diameter of 13 nm were formed between 1.2 and 1.75 #mu#m in depth causing a swelling of 0.1% at the peak, which is larger than those of the specimens irradiated with other conditions. The extent of the cavity-introduced region is some 40% smaller than observed in the damage region due to the He"+ and the O"+ ions and due to the ...
Effects of irradiation on the microstructural evolution and corrosion resistance of zirconium alloys
International Nuclear Information System (INIS)
Zircaloy-2 and Zircaloy-4 tubing materials were irradiated with 1 MeV proton at 350 degrees C to doses of 0.01, 0.1, and 1 dpa respectively. Both microstructure examination and nodular corrosion test (500 degrees C, 1500 psi steam) were performed in order to understand the relationship between the microstructural evolution and the corrosion resistance of these alloys under irradiation. Neutron-irradiated Zircaloy-2 specimens which were obtained from a failed BWR fuel rod cladding were also studied. Specimens of three different neutron fluences were investigated; namely, 2.6x10"2"4, 3.2x10"2"5, 3.8x10"2"5, (E_n#>=#1MeV). The results indicated that the higher the irradiation dose the better the nodular corrosion resistance of both Zircaloy-2 and Zircaloy-4. It is concluded that irradiation-induced precipitate dissolution and irradiation-enhanced diffusion may increase the solute concentration in the matrix and make it ...
1991-08-25
Energy Technology Data Exchange (ETDEWEB)
Whole-body retention and excretion following a single oral dose of radiolabeled lead (/sup 203/Pb) in chronically lead-exposed pregnant BK:W mice were examined over 10-13 days. This was compared with values in similarly treated nonpregnant females and in ip injected females. Whole-body and bone retention were greater in injected than in orally dosed nonpregnant females; gastrointestinal absorption was estimated from this difference. Whole-body retention in the pups was measured at birth and at the end of the experiment. Whole-body retentions in pregnant females and in their pups at birth were significantly raised after treatment at Gestational Day 17, but not after treatment at Gestational Day 11, 14, 20, 23, or 26. Pup body burdens at birth were significantly and positively correlated with maternal retention. Measurement of radioactivity in bone, kidney, brain, heart, and liver of adults at the end of the experiments showed significantly ...
1986-12-01
International Nuclear Information System (INIS)
Whole-body retention and excretion following a single oral dose of radiolabeled lead ("2"0"3Pb) in chronically lead-exposed pregnant BK:W mice were examined over 10-13 days. This was compared with values in similarly treated nonpregnant females and in ip injected females. Whole-body and bone retention were greater in injected than in orally dosed nonpregnant females; gastrointestinal absorption was estimated from this difference. Whole-body retention in the pups was measured at birth and at the end of the experiment. Whole-body retentions in pregnant females and in their pups at birth were significantly raised after treatment at Gestational Day 17, but not after treatment at Gestational Day 11, 14, 20, 23, or 26. Pup body burdens at birth were significantly and positively correlated with maternal retention. Measurement of radioactivity in bone, kidney, brain, heart, and liver of adults at the end of the experiments showed significantly ...
Energy Technology Data Exchange (ETDEWEB)
The proton beam has a unique advantage over the electron and photon beams in that it can give very high radiation dose to the tumor volume, while effectively sparing the neighboring healthy tissue and organs. For the clinical application of the proton beam, it is very important to confirm the location of the proton beam in the patient, preferentially during the treatment. It has been suggested that the range of the proton beam in the patient can be determined by measuring prompt gammas from the proton beam passage. Recently, a prototype prompt-gamma scanning system has been constructed and tested using experimental and therapeutic proton beams. The measurement results for the proton beams of 70 . 230 MeV showed that a clear correlation exists between the distribution of the prompt gammas and the proton beam range. The scanning method, however, is not suitable for the upcoming 'spot scanning' technique. The 'spot ...
2007-07-01
International Nuclear Information System (INIS)
Since 1994 the radon studies group at the Institut de Techniques Energetiques (INTE) of the Universitat Politecnica de Catalunya in Barcelona, Spain, has carried out a campaign of continuous measurements of the equilibrium factor (F) and the unattached fraction (f_p) of radon decay products at four sites which are representative of different environmental characteristics on the Mediterranean littoral of Catalonia, Spain. It has been established that these parameters vary widely, F(0.03--0.87) and f_p (0--0.72), from one site to another and with time, according to the characteristics on the site and climate. In spite of this variation, the F and f_p parameters are log-normally or normally distributed. The measurements of F and f_p show that f_p is negatively correlated to F by a log-power equation, Ln(1/f_p)=1.90[Ln(1/F)]"-"0"."6"8, which can be used in all the F range, instead of the commonly used power equation f_p=aF"b suggested by Stranden and Strand and other ...
2000-01-01
International Nuclear Information System (INIS)
The authors present the results of an investigation of the effect of gamma radiation on the properties of low-molecular moulded polymethyl methacrylates (molecular weight distribution, physico-mechanical properties, resistance to the effects of aqueous media and physiological solution) in the form of copolymers of methyl methacrylate with methyl acrylate (MA) or butyl acrylate (BA) with the brand names Dacryl-4B, Dacryl-2M and Dacryl-4M (4% BA; 2 and 4% MA respectively) having a molecular weight of around 10"5. For comparison, block polymethyl methacrylate with a molecular weight of 3 x 10"6 was used. The results of experiments on the ageing of unirradiated and irradiated specimens in a heated store-room (t = 10 - 20"0C) and at high temperatures (90"0C) are also given. It is shown that irradiation with doses of 2.5 - 20 Mrad leads to radiolysis of the above copolymers, accompanied by destructive processes. Evidence of this is an increase in the ...
1974-12-09
International Nuclear Information System (INIS)
The authors present the results of an investigation of the effect of gamma radiation on the properties of low-molecular moulded polymethyl methacrylates (molecular weight distribution, physicomechanical properties, resistance to the effects of aqueous media and physiological solution) in the form of copolymers of methyl methacrylate with methyl (MA) or butyl acrylate (BA) with the brand names Dacryl-4B, Dacryl-2M and Dacryl-4M (4% BA; 2 and 4% MA respectively) having a molecular weight of around 10"5. For comparison, block polymethyl methacrylate with a molecular weight of 3 x 10"6 was used. The results of experiments on the ageing of unirradiated and irradiated specimens in a heated store-room (t = 10 - 20"0C) and at high temperatures (90"0C) are also given. It is shown that irradiation with doses of 2.5-20 Mrad leads to radiolysis of the above copolymers, accompanied by destructive processes. Evidence of this is an increase in the ...
1975-01-01
C-14 release and transport from a nuclear waste repository in an unsaturated medium
Energy Technology Data Exchange (ETDEWEB)
The release of {sup 14}C as {sup 14}CO{sub 2} from partly failed spent fuel containers has been analyzed by the flow of gases into and out of the containers. This flow of gases is driven by pressure differences, which are in turn caused by heating by the spent fuel. In this analysis, the timing and size of holes in the containers are assumed to be given. A better means of predicting the time distribution and sizes of penetrations in nuclear waste containers is needed. For the purposes of far-field transport calculations, we have adopted release rates that are shown to be bonding for the large range of hole sizes studied. The transport of released {sup 14}CO{sub 2} has been analyzed by transport in equivalent porous medium. The peak {sup 14}CO{sub 2} concentration in pore gas at 350 m above the repository does not depend on the time of hole occurrence, although the time of penetration obviously affects the arrival and duration of exposure to {sup 14}C. Nor does ...
1990-06-01
International Nuclear Information System (INIS)
Objective: To apply the obtained results from 3 stages of research in Chinese radiation protection field. Methods: Based on the identification of physical, chemical and biological qualities for element and its radionuclides under equilibrium condition, main application of these results in Chinese radiation protection field have been discussed by using reported methods in literature. Results: Based on developing elemental reference values of organs or tissues, whole body burdens and their distribution for Chinese Reference Man, discussed in the above 3 articles, current dietary elemental intakes of 42 elements have been updated, and related basis for certain important parameters of bio-kinetic model for use in radiation protection (for example, f_l, T_e and T_b) have been provided. The internal doses from primordial radionuclides and transfer coefficients of elements from environment into the critical organs of Chinese adult men have been ...
2007-08-01
166Ho-HA evaluation as therapeutic agent for rheumatoid arthritis treatment
International Nuclear Information System (INIS)
Aim: Rheumatoid arthritis is a limiting disease having, among its pathological features, the inflammation of synovial tissue with progressive and later destruction of the articulation. This leads to joint deformation and loss of its function, generating pain and reducing the mobility of the affected articulation. The aim was to evaluate "1"6"6Ho-Hydroxyapatite ("1"6"6 Ho-HA) as potential radiopharmaceutical for the symptomatic treatment of chronic and acute arthritis. Materials and Methods: Holmiun-166 was produced by irradiation of Ho_2O_3 at La Reina Research Reactor, Nuclear Chilean Energy Commission. Hydroxyapatite was in-house synthesized. Its labelling and quality controls follows the internationally accepted procedures. An antigen's arthritis was induced to eight New Zealand rabbits with the "1"6"6 Ho-HA radiochemical being administered thereafter in two dosage modalities (single and double). The compound therapeutic efficiency was evaluated based upon clinical improvement and ...
2002-09-01
X-ray dose enhancement effects
International Nuclear Information System (INIS)
A brief description of the physical process of dose enhancement effects produced by X-ray radiation on materials is given, with emphasis on the influence on electronic devices. The damages caused by X-ray radiation dose enhancement is more serious than that of #gamma#-ray with higher energy.
Stochastic risk estimate for barium radiological examinations in Malaga (Spain)
International Nuclear Information System (INIS)
The aim of this research work has been the estimation of the stochastic risk for five barium examinations. The sample was the population attending the Radiological Service of the 'Nuestra Senora de la Victoria' University Hospital, who had been treated with some barium examinations, set in five different groups: oesophagus tract, oesophagus-gastric-duodenal tract, intestinal tract, enteroclysis and double enema. To estimate the stochastic risk, it is necessary to know the organ dose. This can be calculated from the dose-area product which allows us to determine the effective dose using software. The dose-area product is the most suitable quantity to measure in these types of examination. We have evaluated the contribution that each procedure provides to the genetically significant dose, somatically significant dose, collective effective ...
2000-01-01
Induction of bladder cancer in rats by fractionated intravesicular doses of N-methyl-N-nitrosourea.
UK PubMed Central (United Kingdom)
Experiments were conducted to determine the dose response of rat bladder urothelium to a range of different single and fractionated intravesicular doses of the carcinogen, N-methyl-N-nitrosourea (MNU)....Full Text Available
1982-03-01
International Nuclear Information System (INIS)
Objective: To investigate the relationship between exposure dose and image quality for a direct digital radiography system and to determine the optimum exposure parameters for pelvic examination. Methods: A contrast-detail phantom CDRAD2.0 was exposed to different doses and the IQF of phantom images were calculated. The optimum exposure parameters were determined by ANOVA and SNK analysis. The image of an anthropomorphic phantom taken with optimized exposure parameters was verified using CEC image criteria. Results: The IQF of the images of CDRAD2.0 phantom was significantly different for different doses, as the exposure dose was greater than 0.61 mGy. The IQFs have no difference for different dose groups. The image quality between this optimized exposure dose and conventional exposure dose not was significantly different. Conclusion: The ...
2005-10-01
Effects of small doses of ionizing radiation on human health
Energy Technology Data Exchange (ETDEWEB)
The risks to human health from small doses of ionizing radiation raise questions which remain largely unanswered. This paper begins by explaining the historical background to this subject; it goes on to discuss recent developments and concludes with a personal view of the dose-reponse relationship. (author).
1997-12-01
Effects of small doses of ionizing radiation on human health
International Nuclear Information System (INIS)
The risks to human health from small doses of ionizing radiation raise questions which remain largely unanswered. This paper begins by explaining the historical background to this subject; it goes on to discuss recent developments and concludes with a personal view of the dose-reponse relationship. (author).
1997-01-01
UK PubMed Central (United Kingdom)
Purpose:To investigate the clinical usage of dose verification of Helical Tomotherapy plans by using 2D-array ion chambers, and to develop an efficient way to validate the dose delivered...Full Text Available
A two-stage sequential linear programming approach to IMRT dose optimization
UK PubMed Central (United Kingdom)
The conventional IMRT planning process involves two stages in which the first stage consists of fast but approximate idealized pencil beam dose calculations and dose optimization and the second...Full Text Available
2010-02-07
The use of nitrogen isotopes in research on sheep nutrition
International Nuclear Information System (INIS)
Using nitrogen-13 initial measurements have been made of rumen ammonia-nitrogen pool size and turnover, and rate of incorporation of ammonia into microbial protein. It is also feasible to measure the rate of incorporation of absorbed ammonia into urea and the appearance of label in saliva.
1985-08-26
The Neutron Radiography Reactor (NRAD)
The Neutron Radiography Reactor (NRAD) operated by Argonne National Laboratory is described in this paper. NRAD was designed to allow radiography of highly absorbing reactor fuel assemblies in the vertical position on the routine basis. 7 figs.
1990-01-01
The Chemical Reactions of Sulfur in the Citrate Process for Flue Gas Desulfurization.
The Bureau of Mines performed chemical research to elaborate details of sulfur chemistry pertaining to the citrate flue gas desulfurization process in which sulfur dioxide (SO2), absorbed (as bisulfite ion) in a buffered sodium citrate solution, is reduce...
1981-01-01
The Atmospheric Trace ... - NASA Langley Science Directorate
Trace gas molecules absorb specific wavelengths of incoming solar ... These data(with information collected from similar experiments carried on balloons, rockets, ... The ATMOS sensor instrumentis a state-of-the-art version of a 19th century ...
Remote disassembly of the absorber open-test assembly at the FFTF/IEM cell
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF) interim examination and maintenance (IEM) cell is used for the remote disassembly of irradiated fuel and material experiments. The absorber open-test assembly (AOTA) is a 12-m (40-ft)-long instrumented absorber (control-rod-material) test assembly. Its primary purpose is to characterize the FFTF control-rod-material reaction rate during reactor operation. Instrumentation allowed temperature and pressure measurements at various locations in several absorber pins during reactor operation. After residing several months in the reactor, the assembly was transferred to the IEM cell by the closed-loop ex-vessel machine (CLEM) for separation of the irradiated portion of the experiment from the instrument stalk. After separation, the 3.6-m (12-ft)-long assembly was processed through the sodium removal system and shipped off-site for examination. This success allowed the timely completion of a major ...
1990-11-11
Energy Technology Data Exchange (ETDEWEB)
The A(..pi../sup +/,/sup 3/He)B reaction near threshold is studied in a model where the pion is absorbed by an /sup 4/He constituent of the target nucleus. The predictions of this model using harmonic oscillator cluster wave functions agree semi-quantitatively with the experimental data on the inverse reaction.
1982-03-10
Incorporate the latest FGD trends into mist-eliminator design. [Flue gas desulfurization
Mist eliminators for flue gas desulphurisation units remove liquid droplets entrained in the flue gas leaving the SO/sub 2/-absorber vessels. The commercial designs currently available are described.
1984-03-01
Gun Barrel Vibration Absorber to Increase Accuracy
Page 1. Page 2. Page 3. Page 4. Page 5. Page 6. Page 7. Page 8. Page 9. Page 10. Page 11. Page 12. Page 13. Page 14. Page 15. Page 16. Page ...
2002-02-01
GaAs Blocked-Impurity-Band Detectors for Far-Infrared Astronomy
Energy Technology Data Exchange (ETDEWEB)
High-purity and doped GaAs films have been grown by Liquid-phase epitaxy (LPE) for development of a blocked impurity band (BIB) detector for far-infrared radiation. The film growth process developed has resulted in the capability to grow GaAs with a net active impurity concentration below 1 x 10{sup 13} cm{sup -3}, ideal for the blocking layer of the BIB detector. The growth of n-type LPE GaAs films with donor concentrations below the metal-insulator transition, as required for the absorbing layer of a BIB detector, has been achieved. The control of the donor concentration, however, was found to be insufficient for detector production. The growth by LPE of a high-purity film onto a commercially grown vapor-phase epitaxial (VPE) n-type GaAs doped absorbing layer resulted in a BIB device that showed a significant reduction in the low-temperature dark current compared to the absorbing layer only. Extended optical response was ...
2004-12-21
First Measurements of the Inclined Boron Layer Thermal-Neutron Detector for Reflectometry
Energy Technology Data Exchange (ETDEWEB)
A prototype detector based on the inclined absorber layer principle is introduced. For the Liquids Reflectometer at the Spallation Neutron Source, it is shown to be a significant improvement over its current detector, which imposes an instantaneous count rate limitation of 50 kcps.
2008-10-01
Design and Validation of a Gun Barrel Vibration Absorber.
Page 1. Page 2. Page 3. Page 4. Page 5. Page 6. Page 7. Page 8. Page 9. Page 10. Page 11. Page 12. Page 13. Page 14. Page 15. Page 16. Page ...
1997-05-01
Current state of methodology on hemoglobin oximetry in tissues.
Photon migration provides sensitive tissue oximetry in which the optical pathlength is known. Phase array gives the precise location of a subnanomolar amount of hidden absorber in highly scattering medium. PMID:8079713
1994-01-01
Carbon dioxide, climate and the sea
Energy Technology Data Exchange (ETDEWEB)
Only half of the carbon dioxide produced by burning fossil fuels stays in the atmosphere. It is thought that the oceans absorb the rest. To understand the world's climate it is necessary to know how the atmosphere, ocean and biosphere interact.
1985-11-21
Carbon dioxide absorption methanol process
Energy Technology Data Exchange (ETDEWEB)
A process is described for removing carbon dioxide from a feed stream of natural gas, having at least methane, ethane and heavier hydrocarbon, comprising: separating the feed stream in a first separator to form a first stream, having substantially all of the propane and heavier hydrocarbons and carbon dioxide and ethane, and a second stream, having methane, carbon dioxide and ethane; mixing the second stream with a polar compound to form a third stream; separating the vapor and liquid of the third stream in the bottom portion of an absorber; absorbing carbon dioxide and ethane from the separated vapor of Step C in a lean portion of the polar compound in the absorber, the absorber carbon dioxide and ethane forming a fourth stream; separating the ethane from the polar compound and carbon dioxide in a separator; separating the first stream in a third separator to separate the propane and heavier ...
1987-06-23
Black holes as detectors of tachyons
International Nuclear Information System (INIS)
Tachyons fired into and absorbed by rotating black holes can violate the second and third laws of black hole physics. It is suggested that apparent break-downs of these laws in astrophysical black holes can indicate the existence of cosmic tachyons. (author).
Adaptive Gun Barrel Vibration Absorber.
Gun barrel vibrations lead to dispersion in the shot patterns. Thus, reducing these vibrations should lead to increased accuracy. Since the muzzle is the anti-node for all vibration modes and its vibrations have the greatest effect on shot dispersion, it ...
2002-01-01
Absorption of tachyons in extended relativity an answer to Basano
International Nuclear Information System (INIS)
It is answered to a previous letter by Basano, and shown that the difficulties met by that author within ''Extended relativity'' do not exist, but are due to the erroneous assumption that a certain condition for tachyons to be absorbed by a macro-object is sufficient (whilst it is only a necessary one).
UK PubMed Central (United Kingdom)
INTRODUCTIONCutiplast (absorbent perforated dressing with adhesive border; Smith & Nephew) is commonly used following orthopaedic operation, but complications of its use...Full Text Available
2006-01-01
Energy Technology Data Exchange (ETDEWEB)
(3H)Quinuclidinyl benzilate binding to rat brain muscarinic receptors decreased after repeated exposure to soman, a potent organophosphorus cholinesterase inhibitor. The topographical distribution of this decrement was analyzed by quantitative receptor autoradiography. After 4 weeks of soman, three times a week, quinuclidinyl benzilate binding decreased to 67 to 80% of control in frontal and parietal cortex, caudate-putamen, lateral septum, hippocampal body, dentate gyrus, superior colliculus, nucleus of the fifth nerve, and central grey. Minor or no decreases were observed in thalamic or hypothalamic nuclei, reticular formation, pontine nuclei, inferior colliculus, nucleus of the seventh nerve, and cerebellum. Scatchard analyses of saturation curves using frontal cortex sections from soman-treated rats revealed a decrease in maximal quinuclidinyl benzilate binding from that in control rats and a return toward control levels by 24 days without any significant ...
1984-08-01
International Nuclear Information System (INIS)
[3H]Quinuclidinyl benzilate binding to rat brain muscarinic receptors decreased after repeated exposure to soman, a potent organophosphorus cholinesterase inhibitor. The topographical distribution of this decrement was analyzed by quantitative receptor autoradiography. After 4 weeks of soman, three times a week, quinuclidinyl benzilate binding decreased to 67 to 80% of control in frontal and parietal cortex, caudate-putamen, lateral septum, hippocampal body, dentate gyrus, superior colliculus, nucleus of the fifth nerve, and central grey. Minor or no decreases were observed in thalamic or hypothalamic nuclei, reticular formation, pontine nuclei, inferior colliculus, nucleus of the seventh nerve, and cerebellum. Scatchard analyses of saturation curves using frontal cortex sections from soman-treated rats revealed a decrease in maximal quinuclidinyl benzilate binding from that in control rats and a return toward control levels by 24 days without any significant ...
1984-01-01
Monte Carlo simulation of electron cones used in electron beam therapy
International Nuclear Information System (INIS)
A Siemens Mevatron KV2 accelerator installed at the Royal Adelaide Hospital employs cylindrical solid-walled electron cones for some electron collimation. The cones being used at present result in treatment fields that do not always conform with the International Electrotechnical Commission (IEC) Standards (particularly at high energies). The aim of this project was to simulate the existing cones using Monte Carlo methods in order to evaluate potential cone modifications required to overcome the field irregularities. Simulations were performed using the EGS4 (Electron Gamma Shower version 4, distribution II) Monte Carlo code installed on a DEC Alpha workstation at the University of South Australia. To rigorously simulate the existing electron cones it was necessary to also simulate various components within the treatment head of the linear accelerator. Results of simulations for existing cones were found to be consistent with experimental data. (obtained from Royal ...
1998-09-01
Energy Technology Data Exchange (ETDEWEB)
The space environment consists of a varying field of radiation particles including high-energy ions, with spacecraft shielding material providing the only major protection to astronauts from harmful exposure. Unlike low-linear energy transfer (LET) {gamma} or X-rays, the presence of shielding does not always reduce the radiation risks for energetic charged particle exposure, since the dose delivered by the charged particle increases sharply as the particle approaches the end of its range, a position known as the Bragg peak. The Bragg curve does not necessarily represent the biological damage along the particle traversal, and the 'biological Bragg curve' is dependent on the energy and the type of the primary particle, and may vary for different biological endpoints. Here we used a unique irradiation geometry to measure the biological response across the Bragg curve in human fibroblasts exposed to 577MeV/nucleon incident Fe ions in vitro. ...
2006-10-15
Ecological risk assessment of the east branch, Finniss River
International Nuclear Information System (INIS)
Quantitative ecological risk assessment (ERA) is a means whereby the risk posed by a toxicant in any system can be evaluated by comparing the distribution of its measured or modelled concentrations (water quality data (WQD)) with available information on the range of concentrations that are known to adversely affect biota within that, or similar, habitats (dose-response data (DRD)). Initially, the WQD are compared with regulatory criteria (e.g. ANZECC and ARMCANZ, 2000). If they fail this test, then, on the assumption that both data sets comprise subsets of the entire range of concentrations, probability density functions are derived assuming a standard distribution form a typically log-normal. In this paper, AQUARISK has been used to estimate the risk posed by copper in effluent from the Rum Jungle mine site, pre- and post-remediation, and the proportion of taxa likely to be affected in the East Branch (EB) of the Finniss ...
2002-03-01
NEUTRON-ABSORBING BRICKS MADE FROM CaB$sup 6$
nsive neutron-absorbing bricks from commercially available CaB/sub 6/ powder. The bricks are 2 x 3 x 5 in., and are strong enough to withstand normal handling. They last indefinitely; the ones described are now 7 years old, used and stored under normal room temperatures and humidities. The procedure is to make a thick, dry mud with the powder and water, followed by compression in a mold at pressures of about 1 ton/in./sup 2/ or more. The bricks are then baked for 2 hours or longer at a temperature of about 750 deg C. (auth)
1960-05-01
Modeling and Experimental Study of Carbon Dioxide Absorption in a Membrane Contactor
Energy Technology Data Exchange (ETDEWEB)
This dissertation deals with membrane gas absorption in the application of CO{sub 2} removal by aqueous alkanolamines, using microporous PTFE hollow fiber membranes. A new lab-scale apparatus was constructed and an extensive experimental study executed to determine the performance of the membrane gas absorber, with aqueous solutions of monoethanolamine (MEA) and methyldiethanolamine (MDEA) as absorbents. The important operation parameters CO{sub 2} partial pressure, gas velocity, liquid velocity, temperature and liquid CO{sub 2} loading were systematically varied within the range typically experienced in a process for exhaust gas CO{sub 2}-removal
2003-03-15
Analysis of the thermal performance of dynamic solar systems
Energy Technology Data Exchange (ETDEWEB)
This article proposes a model for estimating the effect of the overall thermal resistance of the absorber and the coolant on a solar thermal energy system utilizing advanced heat transfer mediums. Two equations can be used to model a dynamic system: one for the maximum conversion efficiency and one to specify the constraint that, in quasi-steady state, the net energy collected must be transferred to the coolant. These two equations define a constrained optimization problem in two variables, the fluid and the absorber temperatures. The results present interesting implications for liquid metal, direct absorption, and solar evaporating systems.
1996-03-01
Nucleon momentum distributions of 39(K), 40(Ca) and 48(Ca)
Energy Technology Data Exchange (ETDEWEB)
The proton momentum distributions of (39)K,(40)Ca and (48)Ca are calculated from the model-independent charge distributions obtained from analyses of electron elastic scattering and muonic atoms, and also from the charge distributions calculated from the single-particle potential method in the framework of the flucton model. The sensitivities of the momentum distribution to different regions of the charge distribution are determined. The analysis is extended to the neutron distributions using the single-particle potential method, and the differences between the proton and neutron momentum distributions are examined. The resulting momentum distribution in the case of (40)Ca is used for analyzing the quasielastic electron scattering.
1983-01-01
Operational reactor physics analysis codes (ORPAC)
International Nuclear Information System (INIS)
Full text: Research reactors have been playing a multi dimensional role in areas of nuclear fuel cycle programme, radio-isotope productions, neutron beam research etc. To ensure an efficient, smooth and safe operation of a nuclear research reactor, many reactor physics evaluations are required on routine basis. As part of reactor core management the important activities are maintaining core reactivity status, core power distribution, xenon estimations, safety evaluation of in-pile irradiation samples and experimental assemblies and assessment of nuclear safety in fuel handling/storage. In-pile irradiation requires a prior estimation of the reactivity load due to the sample, heating rate and the activity developed in it during irradiation. For the safety of the personnel handling irradiated samples the dose rate at the surface of shielded flask housing the irradiated sample should be less than 200 mR/Hr. Therefore, a proper shielding and ...
Activity patterns in elementary and high school students exposed to oxidant pollution
Energy Technology Data Exchange (ETDEWEB)
We investigated activity patterns of 17 elementary school students aged 10-12, and 19 high school students aged 13-17, in suburban Los Angeles during the oxidant pollution season. Individuals' relationships between ventilation rate (VR) and heart rate (HR) were calibrated' in supervised outdoor walking/jogging. Log VR was consistently proportional to HR; although calibrations' were limited by a restricted range of exercise, and possibly by artifact due to mouthpiece breathing, which may cause overestimation of VR at rest. Each subject then recorded activities in diaries, and recorded HR once per minute by wearing Heart Watches, over 3 days (Saturday-Monday). For each activity the subject estimated a breathing rate--slow (slow walking), medium (fast walking), or fast (running). VR ranges for each breathing rate and activity type were estimated from HR recordings. High-school students' diaries showed their aggregate distribution of ...
1992-07-01
Place matters: multilevel investigation of HIV distribution in Tanzania
UK PubMed Central (United Kingdom)
ObjectiveTo examine the extent to which the regional and neighborhood distribution of HIV in Tanzania is caused by the differential distribution of individual correlates...Full Text Available
2008-03-30
CT-Expo - a novel program for dose evaluation in CT
International Nuclear Information System (INIS)
CT-Expo is a novel MS Excel application for assessing the radiation doses delivered to patients undergoing CT examinations, based on computational methods that were used to analyze the data collected in the German survey on CT practice in 1999. The program enables the calculation of all dose quantities of practical value, such as axial dose free-in-air, weighted CTDI, dose-length product, effective dose and uterine dose. In contrast to existing programs for CT dose assessment, CT-Expo offers a number of unique features, such as gender-specific dose calculation for all age groups (adults, children, newborns), applicability to all existing scanner models including correction of scanner-specific influences, and the possibility of comparison with the results from the German CT survey on CT practice. Three different ...
2002-12-01
Total dose hardening of SIMOX buried oxides for fully depleted devices in rad-tolerant applications
International Nuclear Information System (INIS)
A total dose hardening treatment is applied to SIMOX buried oxides. Total ionizing dose radiation testing is performed on fully-depleted transistors fabricated on both hardened and non-hardened substrates. At 200 krads x-ray dose, the front gate shift is reduced from -0.7 to -0.2 V for FETs built on the hardened wafers.
1996-07-15
Survey of radiation doses to patients from the diagnostic use of X-rays
International Nuclear Information System (INIS)
The National Radiological Protection Board is to carry out a survey of doses received by patients from the diagnostic use of X-rays, beginning in June 1977, and carried out at over 100 National Health Service hospitals. Details are given of the reasons for carrying out the survey and the survey objectives. The survey working methods are discussed, together with methods of calculation of the genetically significant dose. The radiation doses will be measured by a thermoluminescent dosimeter developed specially for the survey. (U.K.).
1977-06-01
International Nuclear Information System (INIS)
... radiation effects human populations low dose irradiation neoplasms radiation
1980-01-01
International Nuclear Information System (INIS)
... organizations irradiation radiation doses radiation effects RADIATIONS.
1982-01-01
Software means of dose consumption planning
International Nuclear Information System (INIS)
Russian 2009 p. 118 Ukraine Mazilov, AV Stadnik, IA NSC 'Kharkiv
2009-02-23
Infrared stimulated luminescence-decay shape from NaCl as a function of radiation doses
Energy Technology Data Exchange (ETDEWEB)
Dose-dependent behavior of the infrared stimulated luminescence (IRSL) decay from NaCl has been studied experimentally using only one aliquot irradiated with a range of 2-200 Gy {beta}-radiation doses. It was observed that the maximum IRSL intensity has not changed by an increase in dose though the total intensity increased as expected. Considering the possible implications of our findings for dosimeter, the results were compared with the other studies and discussed.
2007-11-15
Influencing factors on ESR dose assessment in irradiated chicken legs
Energy Technology Data Exchange (ETDEWEB)
Electron spin resonance (ESR) dosimetry of irradiated chicken legs is based on the additive dose or the calibration curve methods. In both cases the practical assumption is made that the behaviour of the chicken bone does not depend on factors such as temperature during irradiation, storage conditions and dose rate. So the aim of the present work was to investigate to what extent the above mentioned factors could influence the post-irradiation dose assessment using the ESR technique. (author).
1996-12-31
International Nuclear Information System (INIS)
... pathological changes patients radiation protection radiotherapy diseases
1982-10-25
Energy Technology Data Exchange (ETDEWEB)
The risks from radiation exposure during radiological diagnosis has usually been estimated in relation to genetic changes. Relevant information has been expressed as the genetically significant dose. In this paper we attempt to produce an analogous measure for evaluating the somatic risk in the form of a somatically significant dose index for radiological and CT examinations. It is shown that, for both types of examination, the two risk factors may be entirely different.
1980-10-01
International Nuclear Information System (INIS)
The risks from radiation exposure during radiological diagnosis has usually been estimated in relation to genetic changes. Relevant information has been expressed as the genetically significant dose. In this paper we attempt to produce an analogous measure for evaluating the somatic risk in the form of a somatically significant dose index for radiological and CT examinations. It is shown that, for both types of examination, the two risk factors may be entirely different. (orig.).
1980-01-01
Effective dose equivalent in nuclear medicine investigations
International Nuclear Information System (INIS)
... radiation hazards hazards health hazards MEDICINE. SOMATICALLY
1984-05-07
Energy Technology Data Exchange (ETDEWEB)
Collective dose equivalent and population dose from occupational exposures in Japan, 1988 were estimated on the basis of a nationwide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 0.21 million workers except for the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the official report of the Japan Nuclear Safety Commission. The total number of workers including nuclear power stations was estimated to be about 0.26 million. Radiation works were subdivided as follows: medical works including dental; non-atomic energy industry; research and education; atomic energy industry and nuclear power station. For the determination of effective dose equivalent and population dose, organ or tissue doses were measured with a phantom experiment. ...
1993-05-01
International Nuclear Information System (INIS)
Collective dose equivalent and population dose from occupational exposures in Japan, 1988 were estimated on the basis of a nationwide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 0.21 million workers except for the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the official report of the Japan Nuclear Safety Commission. The total number of workers including nuclear power stations was estimated to be about 0.26 million. Radiation works were subdivided as follows: medical works including dental; non-atomic energy industry; research and education; atomic energy industry and nuclear power station. For the determination of effective dose equivalent and population dose, organ or tissue doses were measured with a phantom experiment. ...
1993-01-01
Bulgarian population exposure resulting from diagnostic nuclear-medicine applications
International Nuclear Information System (INIS)
... populations radiation doses RADIOACTIVE MATERIALS. SOMATICALLY
1980-10-26
Distribution Models for Optical Scintillation Due to ...
... Lincoln Laboratory Distribution Models for Optical Scintillation Due to Atmospheric Turbulence RR Parenti RJ Susiela Group 107 ...
2005-12-12
Donut-shaped high-dose configuration for proton beam radiation therapy
Energy Technology Data Exchange (ETDEWEB)
Background: the authors report on the conception and first clinical application of a donut-shaped high-dose configuration for proton therapy (PT). This approach allows one to intensify target volume dose coverage for targets encompassing a critical, dose-limiting structure - like here, the cauda equina -, whilst delivering minimal dose to other healthy structures surrounding the target, thereby reducing the integral dose. Methods and results: intensity-modulated PT methods (IMPT) for spot scanning were applied to create and deliver a donut-shaped high-dose configuration with protons, allowing treating > 75% of the target with at least 95% of the prescribed dose of 72.8 CGE, whilst restricting dose to the cauda equina to 60-65 CGE. Integral dose was lower by a factor of 3.3 as compared to ...
2005-01-01
Donut-shaped high-dose configuration for proton beam radiation therapy
International Nuclear Information System (INIS)
Background: the authors report on the conception and first clinical application of a donut-shaped high-dose configuration for proton therapy (PT). This approach allows one to intensify target volume dose coverage for targets encompassing a critical, dose-limiting structure - like here, the cauda equina -, whilst delivering minimal dose to other healthy structures surrounding the target, thereby reducing the integral dose. Methods and results: intensity-modulated PT methods (IMPT) for spot scanning were applied to create and deliver a donut-shaped high-dose configuration with protons, allowing treating > 75% of the target with at least 95% of the prescribed dose of 72.8 CGE, whilst restricting dose to the cauda equina to 60-65 CGE. Integral dose was lower by a factor of 3.3 as compared to ...
2005-01-01
An evaluation of low-dose single-slice helical CT in pulmonary CT scan
International Nuclear Information System (INIS)
Objective: To investigate the feasibility of low-dose single-slice helical CT in pulmonary CT scan and evaluate the clinical application. Methods: Thirteen cases were selected out of 132 cases, in which low-dose (50mAs) single-slice helical CT scan of chest was performed. This set of cases included 7 cases of multiple metastatic nodules; 3 of solitary pulmonary, nodule; and 3 of pulmonary patchy lesions. Regular dose (170mAs) CT scan was also performed on all those patients. The regular dose and low dose CT scan were compared on sensitivity of detecting the lesions; the performance in demonstrating the details of the abnormalities; and the capability of revealing the segmental bronchi as well. Results: The same number and size of the pulmonary nodules were revealed with scan modalities loaded with different doses. No significant difference in demonstrating the ...
2006-04-01
Study of silicon damage caused by ultra-low energy boron implantation
International Nuclear Information System (INIS)
Ultra-shallow junction formation in deep submicron Si devices is limited by anomalous diffusion of the dopant, which is related to the release of interstitials from defect clusters formed during the implantation of energetic ions or the subsequent annealing. The work described in this dissertation is concerned with the effects of low energy B ion implantation, especially damage formation, clustering and its annealing. After a review of the stopping and ranges of energetic ions in Si, the formation of implant damage, in particular of point defects, their migration, agglomeration and annihilation, including the involvement of dopant ions, is considered. A description of the Salford ultra low energy implanter is given and the main analysis technique, medium ion energy scattering (MEIS) reviewed. Additional analytical techniques used, such as secondary ion mass spectrometry (SIMS), 4-point probe and cross section transmission microscopy (XTEM) as well as TRIM simulation are briefly ...
In vitro and in vivo analysis of pegulated Avidin
Energy Technology Data Exchange (ETDEWEB)
Full text: In 1995, we demonstrated the use of pretargetting three steps method and biotinylated tetracycline using radiolabelled {sup 99m}Tc-DTPA-biocytinamide for the detection of tumour cells in (C57B1/6 x BALB/C) F1 mice with E-3 thymoma. The three steps were (1) IP injection of biotinylated-tetracycline conjugate (1:1) ratio, (2) 96 hours later Avidin/Streptavidin was injected, and (3) 24 hours after (2), {sup 99m}Tc-biocytinamide -cDTPA was injected. Mice were sacrificed 16/24 h after (3) by cervical dislocation. Biodistribution of radioactivity tumour to blood, liver, bone were T:B1= 15.0, T:Li= 5.08, T:Bo=15.0. The percentage of injected dose per g was T= 3.15% and B1= 0.21%. To prolong circulation of Avidin and therefore its uptake into tumour, Avidin was covalently bound to polyethylene-glycol (PEG20 KD) at the molar ratio of PEG:Avidin 100:1 and 400:1. The pegulated Avidin was then cleared from the circulation using Dextran-70-Biotin. The ...
1997-09-01
Project SAFE. Update of the SFR-1 safety assessment. Phase 1. Appendix A1: Inventory
Energy Technology Data Exchange (ETDEWEB)
One of the aims in the safety assessment of SFR-1 is to estimate the release to the environment. In order to make these calculations there is a need to describe the inventory in greater detail. The new computerised database of waste in SFR-1 gives a good possibility to achieve this. The aim for project SAFE is to make both conservative and realistic radionuclide transport calculations. To achieve this goal there must be two inventories. The conservative inventory is the inventory used in the design of the repository, which in most parts is identical with the limits in the licence for SFR-1. There is a great interest to have good estimates of the volumes of the different waste types. A thorough prognosis should be made in 1999, but until then the latest one from 1995 could be used in the calculations. The total (actual) inventory of nuclides is calculated from the measurements of the easy-to-measure nuclides since, in principle, all hard-to-measure nuclides are calculated by correlation ...
1998-10-01
Individual Radiation Protection Monitoring in the Marshall Islands: Rongelap Atoll (2002-2004)
Energy Technology Data Exchange (ETDEWEB)
The United States Department of Energy (U.S. DOE) has recently implemented a series of strategic initiatives to address long-term radiological surveillance needs at former U.S. nuclear test sites in the Marshall Islands. The plan is to engage local atoll communities in developing shared responsibilities for implementing radiation protection monitoring programs for resettled and resettling populations in the northern Marshall Islands. Using the pooled resources of the U.S. DOE and local atoll governments, individual radiological surveillance programs have been developed in whole body counting and plutonium urinalysis in order to accurately assess radiation doses resulting from the ingestion and uptake of fallout radionuclides contained in locally grown foods. Permanent whole body counting facilities have been established at three separate locations in the Marshall Islands including Rongelap Atoll (Figure 1). These facilities are operated and maintained by ...
2006-01-17
Multiphase reacting flow modeling of singlet oxygen generators for chemical oxygen iodine lasers.
Energy Technology Data Exchange (ETDEWEB)
Singlet oxygen generators are multiphase flow chemical reactors used to generate energetic oxygen to be used as a fuel for chemical oxygen iodine lasers. In this paper, a theoretical model of the generator is presented along with its solutions over ranges of parameter space and oxygen maximizing optimizations. The singlet oxygen generator (SOG) is a low-pressure, multiphase flow chemical reactor that is used to produce molecular oxygen in an electronically excited state, i.e. singlet delta oxygen. The primary product of the reactor, the energetic oxygen, is used in a stage immediately succeeding the SOG to dissociate and energize iodine. The gas mixture including the iodine is accelerated to a supersonic speed and lased. Thus the SOG is the fuel generator for the chemical oxygen iodine laser (COIL). The COIL has important application for both military purposes--it was developed by the US Air Force in the 1970s--and, as the infrared beam is readily absorbed by ...
2008-08-01
Whole-body counting in the Marshall Islands
Energy Technology Data Exchange (ETDEWEB)
In 1978 the Marshall Islands Radiological Safety Program was organized to perform radiation measurements and assess radiation doses for the people of the Bikini, Enewetak, Rongelap and Utirik Atolls. One of the major field components of this program is whole- body counting (WBC). WBC is used to monitor the quantity of gamma- emitting radionuclides present in individuals. A primary objective of the program was to establish {sup 137}Cesium body contents among the Enewetak, Rongelap and Utirik populations. {sup 137}Cs was the only gamma-emitting fission radionuclide detected in the 1,967 persons monitored. {sup 137}Cs body burdens tended to increase with age for both sexes, and were higher in males. The average {sup 137}Cs dose Annual Effective Dose for the three populations was as follows: For Enewetak, the dose was 22{+-}4 {mu}Sv. For Utirik, the dose was 33{+-} 3 {mu}Sv. Since 1985 ...
1991-01-01
The somatically significant dose, SSD, and analog of the GSD, the genetically significant dose
International Nuclear Information System (INIS)
The medical applications of radiation comprise three main fields namely: Diagnostic Radiology, Radiotherapy and Nuclear Medicine. With the new weighting factors of ICRP (IC91a) the effective dose due to medical applications can be established. I is common to separate the effective dose into the genetic part and the somatic part, SED. In dealing with gonad doses it is important to account for the age of the person at the time of exposure as this will influence the number of children still to be expected from that person. The resulting dose will then be called the genetically significant dose, GSD. In a similar fashion this age factor will be important in considering the chance of tumor induction. The age of patients differs considerably from the average age of the general population. This age difference has to be accounted for if a comparison is to be made with other sources of ...
1991-11-01
Safety assessment for clearance of radioactive metal wastes from nuclear facility
Energy Technology Data Exchange (ETDEWEB)
Safety assessments for clearance of H-beam and valves, main radioactive metal wastes in Kori nuclear power plants, were carried out to derivate a decontamination factor for satisfying the dose limits of clearance level (Maximum individual dose: 10 {mu}Sv/y, collective dose: 1 man{center_dot}Sv/y) in Korea. Maximum individual dose and collective dose were evaluated by internal dose conversion factor which based on the concept of effective dose in ICRP publication 60. The results of maximum individual dose and collective dose is 139 {mu}Sv per year and 0.166 man{center_dot}Sv per year about H-beam, and 158 {mu}Sv per year and 0.468 man{center_dot}Sv per year about valves respectively. Demand decontamination factor satisfied with, which is respectively more than 13.9 and 15.8 for satisfying clearance ...
2003-10-01
Safety assessment for clearance of radioactive metal wastes from nuclear facility
International Nuclear Information System (INIS)
Safety assessments for clearance of H-beam and valves, main radioactive metal wastes in Kori nuclear power plants, were carried out to derivate a decontamination factor for satisfying the dose limits of clearance level (Maximum individual dose: 10 #mu#Sv/y, collective dose: 1 man#centre dot#Sv/y) in Korea. Maximum individual dose and collective dose were evaluated by internal dose conversion factor which based on the concept of effective dose in ICRP publication 60. The results of maximum individual dose and collective dose is 139 #mu#Sv per year and 0.166 man#centre dot#Sv per year about H-beam, and 158 #mu#Sv per year and 0.468 man#centre dot#Sv per year about valves respectively. Demand decontamination factor satisfied with, which is respectively more than 13.9 and 15.8 for satisfying clearance ...
2003-10-01
Tin-oxide-coated anodized aluminium selective absorber surfaces. Pt. 2. Aging and durability
Energy Technology Data Exchange (ETDEWEB)
Accelerated aging tests on tin-oxide-coated anodized aluminium selective absorber surfaces have been performed. It is shown that the tin oxide layer provides excellent protection for the anodized surface. The thermal stability of the double layer is equal to, or better than, the stability of the bare anodized surface. Both surfaces degrade very slowly at 450deg C. The anodic layer is porous and therefore not very scratch resistant and it degrades when exposed to humidity, both acidic and alcaline. It is shown that the tin oxide film, which is hard and chemically very stable, almost completely protects the anodized surface from chemical degradation. The mechanical wear resistance is also considerably improved. The optical selectivity does not quite match that of the the anodized surface, but the remarkable stability together with the solar parameters of {alpha}=0.91 and hemispherical emittance {epsilon}= 0.16 (normal emittance {epsilon}{sub n}=0.12) make this ...
1991-03-01
Seismic migration and absorbing boundaries with a one-way wave system for heterogeneous media
Energy Technology Data Exchange (ETDEWEB)
A first-order one-way wave system has been created based on characteristic analysis of the acoustic wave system and optimization of the dispersion relation. The authors demonstrate that this system is equivalent to a third-order scalar partial-differential equation which, for a homogeneous medium, reduces to a form similar to the 45{degree} paraxial wave equation. This system describes accurately waves propagating in a 2D heterogeneous medium at angles up to 75{degree}. The one-way wave system representing downgoing waves is used for a modified reverse time migration method. As a wavefield extrapolator in migration, the downgoing wave system propagates the reflection events backwards to their reflectors without scattering at the discontinuities in the velocity model. Hence, images with amplitudes proportional to reflectivity can be obtained from this migration technique. They present examples of the application of the new migration method to synthetic seismic data where P-P reflections ...
1996-07-01
Radiative transfer in a solar absorbing particle laden flow
A possible receiver configuration is a cavity in which a falling sheet of solid particles is directly irradiated by the concentrated solar flux passing through the aperture. Regardless of the particular geometry, the radiative transfer within the falling particle curtain must be studied in order to determine the net radiative heating rate for the particles. A discrete ordinate radiative transfer model has been developed to predict the radiative coupling within the falling particle curtain. The model determines how much energy is absorbed by the particles, how much is transmitted to the rear wall of the receiver, and determines the effects of particle scattering and thermal emission on the net radiation absorbed by the particles. The model accounts for the directional nature of the radiation field, particle scattering, and the wavelength dependence of the optical properties. The discrete ordinate model has been used to assess the influence of ...
1985-11-01
Parametric Resonance Ionization Cooling and Reverse Emittance Exchange for Muon Collider
Energy Technology Data Exchange (ETDEWEB)
Two methods to cool muon beams deeply below the limit conventionally established for the ionization cooling are proposed. In Phase Ionization Cooling (PIC), the beam is focused at wedge absorber plates each half of particle oscillation period by imposing a weak parametric resonance along the beam path. The resonance growth of particle amplitude is surmounted by the ionization cooling. At optimum, such arrangement results in reduction of each of two transverse emittances by an order of value in addition to the preceding 6D ionization cooling. Next, resonance focusing and transverse cooling can be continued in the regime of a fast Reverse Emittance Exchange (REMEX). Here, the sign of the absorber wedge is opposite to PIC while the dispersion increased. REMEX to be accompanied by the bunch lengthening and acceleration in order to maintain the relative energy spread at an appropriate level. The limitations due to energy straggling in ...
2005-09-18
Osmoregulation in the Avena coleoptile: control of solute uptake in peeled sections
Energy Technology Data Exchange (ETDEWEB)
Peeled Avena sativa coleoptile sections have been used to study the control of solute uptake under conditions where the uptake is not limited by the cuticular barrier. In the presence of 2% sucrose, auxin enhances the rate at which the total osmotic solutes increase, but this appears to be a response to the increased growth rate, inasmuch as the auxin effect is eliminated when growth is inhibited osmotically. When sections are incubated in sucrose or in 10 millimolar NaCl, the osmotic concentration increases until a plateau is reached after 8 to 24 hours. Auxin has no effect on the initial rate of increase in osmotic concentration. This difference in steady-state osmotic concentration is, in part, a response to auxin itself, as it persists when auxin-induced growth is inhibited osmotically. The upper limit for osmotic concentration does not appear to be determined by the turgor pressure, inasmuch as a combination of sucrose and NaCl gave a higher plateau osmotic concentration than did ...
1982-01-01
Advanced Flue Gas Desulfurization (AFGD) Demonstration Project, A DOE Assessment
The AFGD process as demonstrated by Pure Air at the Bailly Station offers a reliable and cost-effective means of achieving a high degree of SO{sub 2} emissions reduction when burning high-sulfur coals. Many innovative features have been successfully incorporated in this process, and it is ready for widespread commercial use. The system uses a single-loop cocurrent scrubbing process with in-situ oxidation to produce wallboard-grade gypsum instead of wet sludge. A novel wastewater evaporation system minimizes effluents. The advanced scrubbing process uses a common absorber to serve multiple boilers, thereby saving on capital through economies of scale. Major results of the project are: (1) SO{sub 2} removal of over 94 percent was achieved over the three-year demonstration period, with a system availability exceeding 99.5 percent; (2) a large, single absorber handled the combined flue gas of boilers generating 528 MWe of power, and no spares were ...
2001-08-31
A hydroxide mixture as working fluid for absorption heat pumps
Energy Technology Data Exchange (ETDEWEB)
Basic experimental investigations were carried out with an aqueous solution of a mixture of KOH and NaOH for use as an absorbent in absorption heat pumps. Due to its thermophysical properties this mixture allows temperature lifts from evaporator to absorber of more than 75 K (135 F) in a single-stage absorption chiller. Thermophysical and hydrodynamical properties of the solution were measured. Vapor-liquid-equilibrium data and specific heat capacities were determined for concentrations ranging from 35% up to 75% and temperatures up to 200 C (392 F). From these data the enthalpy of the solution was calculated. Additionally the crystallization temperatures, the density, and the viscosity of the solution were determined. The experimental equipment is described. The data are presented as polynomials and diagrams including experimental accuracy. An apparatus was constructed to measure heat and mass transfer coefficients of the absorption process ...
1996-11-01
Dosimetry limitations and a dose correction methodology for step-and-shoot IMRT
Energy Technology Data Exchange (ETDEWEB)
For the step-and-shoot intensity-modulated radiation therapy (IMRT) technique, the combination of high dose rate, multiple beam segments and low dose per segment can lead to significant differences between the planned dose and the dose delivered to the patient. In this technique, a dose delivery inaccuracy known as the 'overshoot' effect is caused by the dose servo control system. This typically occurs in the first and last beam segments and causes an over- and underdose, respectively. Some dose positional error in the segment sequence is also possible there. Commercial ionization chambers (RK-type) and radiographic Kodak films were used for the measurements. The reported results were obtained using the Pinnacle{sup 3}-V6.2 treatment planning system and a Varian Clinac 21 EX linear accelerator equipped with a 120-leaf ...
2006-02-07
The development of thyroid dose assessment software for nuclear or radiological emergency
International Nuclear Information System (INIS)
Objective: To develop software for assessment of dose to thyroid gland in emergencies resulting in the release of radioiodine. Methods: Based on procedures for thyroid monitoring and dose assessment introduced in IAEA publications (IAEA-TECDOC-1092 and EPR-MEDICAL-2005), a software was developed with Visual Basic 6.0 program to computerized the methods of thyroid dose estimation. Results: The intake of radioiodine and committed equivalent dose to thyroid could be estimated rapidly and accurately with the present software. Conclusion: The present software provide a practical and rapid tool for estimating thyroid doses received in emergencies resulting in the release of radioiodine by emergency workers and members of public, which is necessary for recommendation of further actions. (authors)
2006-12-01
Energy Technology Data Exchange (ETDEWEB)
When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).
1991-08-01
International Nuclear Information System (INIS)
When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).
1991-01-01
Influence of the X-ray radiation on the lifetime of carriers in the p-n junctions of Si and Ge
International Nuclear Information System (INIS)
Lifetime of minority charae carriers in the Si and Ge p-n unctions has been measured by pulse method of conductivity modulation of base. Its dependence on the X-ray radiation dose has been investigated. Dependence of current transmission coefficients on the dose has been measured and their sharp decrease at low doses and the following saturation at high doses have been observed. Linear dependence of lifetime on X-ray radiation dose has been obtained. Resulting from the comparison of regularities of the change of lifetime due to current characteristics, it has been shown that X-ray radiation leads to the formation of the surface defects, influencing the change of current characteristics as well as to stationary structural defects, causing the decrease of lifetime of the charge carriers with the increase of X-ray radiation dose.
Effect of Nordic diets on ECOSYS model predictions of ingestion doses
British Library Electronic Table of Contents (United Kingdom)
The ECOSYS model is used to estimate ingestion dose in the ARGOS and RODOS decision support systems for nuclear emergency management. It is recommended that nation-specific values for several parameters are used in the model. However, this is generally overlooked when the systems are used in practice. We have estimated first year ingestion doses in two scenarios with wet and dry deposition of 137Cs, using the ECOSYS model. We calculated doses for each country using national dietary data while keeping all other parameters at their default values. These dose calculations were then used to estimate the variation in ingestion doses resulting from the variation in the diets only. The dietary data demonstrated that the average consumption of milk, meat and vegetables varied by a factor of 2-4 am...
2010-01-01
Dose enhancement in bone in electron beam therapy
Energy Technology Data Exchange (ETDEWEB)
This study investigated dose to bone tissue in electron beam therapy. Measurements were made using films and thermoluminescent dosimeters in a polystyrene phantom containing bone inhomogeneity for 15-MeV, 12-MeV, and 9-MeV electron beams. An increase in dose of approximately 18%, 12%, and 11%, for the three electron energies respectively, relative to the dose in polystyrene, was found for bone material having an electron density (relative to water) of 1.73. Measurements were also made using films for 15- and 9-Mev electrons in a phantom with a mandibular bone and teeth. A dose enhancement in bone of approximately 10% and 7%, respectively, for the two energies was found in the phantom where the electron density of bone was about 1.60. These results suggest that injury to bone is possible in those clinical situations where high doses of electrons are used for therapy.
1984-05-01
Dose enhancement in bone in electron beam therapy
International Nuclear Information System (INIS)
This study investigated dose to bone tissue in electron beam therapy. Measurements were made using films and thermoluminescent dosimeters in a polystyrene phantom containing bone inhomogeneity for 15-MeV, 12-MeV, and 9-MeV electron beams. An increase in dose of approximately 18%, 12%, and 11%, for the three electron energies respectively, relative to the dose in polystyrene, was found for bone material having an electron density (relative to water) of 1.73. Measurements were also made using films for 15- and 9-Mev electrons in a phantom with a mandibular bone and teeth. A dose enhancement in bone of approximately 10% and 7%, respectively, for the two energies was found in the phantom where the electron density of bone was about 1.60. These results suggest that injury to bone is possible in those clinical situations where high doses of electrons are used for therapy.
Analysis of photon beam exit dose using photon point kernels
International Nuclear Information System (INIS)
The Monte Carlo method is used to analyse the dose fall-off at the exit surface of a megavoltage photon beam. The convolution/superposition method of dose calculation using Monte-Carlo-generated homogeneous photon kernels is shown to be in error for exit dose calculation. Instead, photon kernels that incorporate modelling of the exit surface were generated, also using Monte Carlo, to analyse the problem, and the calculated dose fall-off using these kernels agrees well with measured data. In addition, the physics underlying the characteristics of the dose fall-off is analysed based on complete Monte Carlo modelling. Practical improvements to the convolution/superposition method are suggested. (Author).
Transuranic separation using organophophorus extractants adsorbed onto superparamagnetic carriers.
Energy Technology Data Exchange (ETDEWEB)
Polymeric coated ferromagnetic carriers with an absorbed layer of octyl(phenyl)-N,N-diisobutylcarbamoylmethylphosphine oxide (CMPO) diluted by tributyl phosphate (TBP) are being evaluated for application in the separation and the recovery of low concentrations of americium, plutonium, and uranium from nuclear waste solutions. Due to their chemical nature, these extractants selectively complex americium and plutonium contaminants onto the particles and the complexed particles can be recovered from the solution using a magnet. Physical and chemical characterization of the extractant-absorbed particles were performed by gamma and liquid scintillation counting, scanning electron microscopic (SEM) micrograph, and other physical measurements. Plutonium, americium, and uranium separations have been performed at various HNO{sub 3} and HCl concentrations. Parameters were studied to determine the limitations and capacity of the process. The status of the ...
1998-10-07
Thermal gradient humidification-dehumidification desalination system
Energy Technology Data Exchange (ETDEWEB)
A solar energy desalination process utilizing solar radiation directly for the evaporation of salt water is described. Ambient air takes on water vapor as the air passes through an evaporative medium. It is then directed between a saline water-covered, solar absorbing surface and a solar collecting housing. The resulting heated and moisture-saturated air is cooled in a heat exchange means where condensation of fresh water occurs. Simultaneously, cool salt water is utilized as the cooling water in the heat exchange means, and takes on the heat of condensation given up by the condensing vapor. The heated salt water from the heat exchange means is partially directed over the solar absorbing surface, and at least a portion of it is also directed to wet the evaporative medium. Several optional sub-processes are described for operation of the system during periods of reduced insolation, and an alternative process is described for operation of the ...
1982-12-14
Flux enhancement options for an LEU-fueled MIT reactor
International Nuclear Information System (INIS)
The Monte-Carlo transport code MCNP was used to evaluate possible arrangements of cores for the MIT Reactor using monolithic LEU fuel. Plate and moderator thicknesses were varied, and fixed absorbers and inner reflectors added in an effort to maximize available neutron fluxes at in-core and ex-core locations of experimental facilities. Addition of D_2O in the H_2O moderator was also evaluated. Comparisons of the fast, epithermal, and thermal fluxes were made at selected locations. Keff was also evaluated and critical blade heights compared with the existing HEU core. Results indicate that the LEU fluxes could approach HEU values with the use of a fueled in-core experimental facility, a fixed boron absorber spider and an inner beryllium reflector. (author)
2004-11-07
Enhanced carbon dioxide removal by promoted hot potassium carbonate in a split-flow absorber
Energy Technology Data Exchange (ETDEWEB)
In this work, a comprehensive model has been developed for the absorption of carbon dioxide into promoted hot potassium carbonate solution. The model, which is based on penetration theory, incorporates an extensive set of important reactions and takes into account the coupling between mass transfer and chemical kinetics. The penetration theory provides an appropriate absorption rate and enhancement factor for the chemical absorption. Operating data for carbon dioxide absorption into DEA-hot potassium carbonate solution has been compared with model predictions. The impact of parameters such inlet temperature of lean solution, promoter concentration, liquid split fraction, hot feed location and type of promoter on the performance of a split-flow absorber have been examined. The use of other promoters is an efficient way to enhance the carbon dioxide absorption, which has been discussed in this paper.
2004-07-01
Combined radiation and convection in absorbing, emitting, nongray gas-particulate tube flow
Energy Technology Data Exchange (ETDEWEB)
The interaction of thermal radiation with conduction and convection in thermally developing absorbing, emitting, nongray gas-particulate turbulent suspension flow through a circular tube is investigated. The contribution of thermal radiation is obtained through evaluation of the total hemispherical emittance of the particulate cloud and through evaluation of single band absorptances for molecular gases, modified to account for the interaction with the particles. The governing differential equation is derived as a (nonlinear) energy equation, coupled with integral equations to find the thermal radiation contributions. The energy equation is solved numerically by an implicit finite difference method with an iterative procedure. Qualitative results for Nusselt numbers are shown for a variety and range of parameters, such as optical thickness of particulates and single molecular gas bands, relative gas band position and band width, and temperature ratios (heated as ...
1987-05-01
Combined radiation and convection in absorbing, emitting, non-Gray gas-particulate tube flow
Energy Technology Data Exchange (ETDEWEB)
The interaction of thermal radiation with conduction and convection in thermally developing absorbing, emitting, non-gray gas particulate turbulent suspension flow through a circular tube is investigated. The contribution of thermal radiation is obtained through evaluation of the total hemispherical emittance of the particulate cloud and through evaluation of single band absorptances for molecular gases, modified to account for the interaction with the particles. The governing differential equation is derived as a (nonlinear) energy equation, coupled with integral equations to find the thermal radiation contributions. The energy equation is solved numerically by an implicit finite difference with its iterative procedure. Qualitative results for Nusselt numbers are shown for a variety and range of parameters, such as optical thickness of particulates and single molecular gas bands, relative gas band position and band width, and temperature ratios (heated as well as ...
1985-01-01
Chatter resistance of non-uniform turning bars with attached dynamic absorbers—Analytical approach
British Library Electronic Table of Contents (United Kingdom)
Forced harmonic vibration of a non-uniform elastic beam with attached dynamic vibration absorbers (DVA) is studied. Analytical approximation of the solution is obtained by the functional perturbation method (FPM). The problem has application to cutting tools operations where the resistance of the tool holder against regenerative chatter can be enhanced by optimizing the real part of the frequency response function (FRF). A test case of a beam with step-like heterogeneity and single DVA at the tip shows that the FPM solution is very accurate for up to ?40 percent deviation in both stiffness and mass density. Using the analytical results and Sims approach, optimal DVA tuning is found for each set of beam heterogeneity parameters by solving a set of nonlinear algebraic equations numer...
2010-01-01
Absorption of carbonyl sulfide in aqueous methyldiethanolamine
Energy Technology Data Exchange (ETDEWEB)
The absorption of carbonyl sulfide in aqueous methyldiethanolamine (MDEA) was studied over a range of temperatures and MDEA concentrations. MDEA is commonly used for selective absorption of hydrogen sulfide in the presence of carbon dioxide. However, sulfur in the form of COS may also be present and it is necessary that estimates of absorption rates of this compound be made. The objective of this study is to determine the physiochemical properties needed to predict COS absorption rates in aqueous MDEA. Free gas solubility and the diffusivity of COS in MDEA solutions were measured over the temperature range 15 to 40{sup 0}C for MDEA concentrations up to 30 weight per cent using the nitrous oxide analogy method. Solubilities were measured volumetrically in an equilibrium cell and diffusivities were measured using a laminar liquid jet absorber. The kinetics of the reaction between COS and MDEA were studied by measuring absorption rates in a single wetted-sphere ...
1988-01-01
Reduced "9"9"mTc labelled NCA-95/CEA-antibody uptake in liver due to gentle antibody reconstitution
International Nuclear Information System (INIS)
The influence of reconstituting a murine monoclonal IgG_1 antibody kit with pertechnetate Tc99m on antibody distribution in the liver, spleen and sternal bone marrow of patients was examined. The "9"9"mTc-labelled antibody used is directed against non-specific cross-reacting antigen (NCA-95) and carcinoembryonic antigen (CEA) and has been successfully applied for imaging tissue inflammation and bone marrow scanning. Radioactivity uptake was determined in the liver, spleen, bone marrow and a precordial background region in a consecutive series of 25 patients, examined with an antibody preparation, routinely radiolabelled according to the manufacturer's recommendations and in 14 patients, in whom the antibody was reconstituted with special care, avoiding bubble formation and dropping of buffer into the antibody-containing vial. Gentle compared with routine antibody reconstitution caused a highly significant reduction of the antibody uptake in the liver, as determined ...
Molecular dynamics studies of silicon ion implantation
Energy Technology Data Exchange (ETDEWEB)
Results are presented of molecular dynamics (MD) studies of 1-10 keV displacement cascades in silicon. At these energies, the simulations couple directly to experimental observations of low energy implantation in silicon for shallow junction formation. The simulations are performed with the Stillinger-Weber potential for silicon in computational cells with up to 3.5x10{sup 5} atoms. The author employs periodic boundary conditions in the [100] and [010] directions and a free surface on the top (001) plane. The author discusses the results in terms of the structural evolution and the dynamics of the cascade zones. For sufficiently high energy recoils (>2 KeV), the cascades produce locally molten zones that result in the formation of amorphous silicon pockets upon recrystallization. Frenkel pairs are also produced during the cascade, although their number is very small (less than 10% of the binary collision predictions). Upon annealing of the resulting damage microstructure at 1100K ...
1994-12-31
International Nuclear Information System (INIS)
One rationale proposals to increase the efficiency of PDT is to combine photo-sensitization with other treatment modalities, including modulation of arachidonic acid metabolism. In combine treatment we examined the effects of 48 h and 24 h pre-treatment of cells with 5- lipoxygenase inhibitor MK-886 prior to photoactivation of hypericin on cell cycle distribution and DNA synthesis. All parameters were examined 24 hours after hypericin activation. Pre-treatment of HT-29 with 5-lipoxygenase inhibitor MK-886 followed by PDT resulted in most significant effects on cell cycle perturbations. Administration of MK-886 alone as well as combination of low doses MK-886 with hypericin induced S phase accumulation. Increasing of MK-886 concentration induced massive changes in the cell cycle progression. Pre-treatment of HT-29 cells with MK-886 alone (15 #mu#M; - 48 h) caused accumulation of cells in S-phase (58 % in S-phase and 36 % in G_0/G_1 phase). ...
2006-05-01
International Nuclear Information System (INIS)
Apricot fruits usually harvested relatively mature but hard enough to withstand-post harvest handling through the marketing chain. These fruits have considerably lower edible quality than tree-ripened fruit. Fruit quality can be improved by delaying harvest least until physiological maturation is completed on the tree (Bonghi et al. 1999) Apricots containing 11% soluble solids concentration, or higher are in high demand by consumers, as fruit have developed considerable taste, aroma and handling for long distance markets. (Kader, 1999). These fruit will be highly perishable, so rapid cold storage to the lowest safe temperature and supplementary treatments (Mc Donald et al, 1999) such as irradiation with the recommend doses (Sillano et al, 1994) or pre-storage heat treatments will be necessary to retard ripening (mainly softening) during 1-2 weeks post harvest life necessary for distribution to distant markets (Mc Donald et al 1999). Therefore, ...
2003-03-01
International Nuclear Information System (INIS)
Nuclear Reaction Analysis (NRA) with deuteron ion beams has been used to probe for ion implanted nitrogen and carbon with high sensitivity in zinc oxide and silicon single crystals. The ion implanted N was measured using 1.4 MeV deuteron ion beams and was found to be in agreement with calculated values. The limit of detection for N in ZnO is 8x1014 ions cm-2. Raman measurements of the ion implanted samples showed three additional modes at 275, 504, and 644 cm-1 compared to the un-implanted ZnO crystals. The NRA and Raman results provided information on the N concentration, depth distribution, and structural changes that occur in dependence on the nitrogen ion fluences. The deuterium induced 12C(d,p)13C reaction was used to measure the carbon impurity/dose in ion implanted silicon. It was found that the use of a large cold shield (liquid nitrogen trap) in the ion implanter chamber greatly reduces the amount of carbon impurity on the surface of ...
2008-11-03
Challenges in environmental radiological surveillance around nuclear facilities
International Nuclear Information System (INIS)
To accomplish the environmental radiological surveillance need of India's ambitious nuclear power programme, Health Physics Division is infusing new technologies and improved analytical techniques for day to day measurements of various radionuclides in different environmental matrices. It is essential to have techniques for measuring the concentration of radionuclides just above the background level since the discharges from the nuclear facilities are very low i.e. in the range of 5-10% of the prescribed discharge limits by the regulatory bodies. In view of developing ultra-sensitive techniques, the aim of ongoing programmes of the division is to meet the challenges of measuring ultra trace level of radioactivity by adopting state of art new instrumentation and improved sample processing techniques. This will allow us to measure the lowest level of radioactivity (3H, 90Sr, 137Cs, 239+240Pu, etc.) in the environment and thereby estimating the lowest doses to the ...
2007-06-05
Accelerators for proton and heavy ion radiotherapy
Energy Technology Data Exchange (ETDEWEB)
The construction of Heavy Ion Medical Accelerator in Chiba (HIMAC) at the National Institute of Radiological Sciences was completed in December 1993. HIMAC consists of an injector linac, two synchrotron rings, a high energy beam transport system and a beam irradiation system. Its accelerator parameters are based on the medical requirement, and helium, carbon, neon, silicon and argon were selected as the accelerated ion species. It has 3 therapy rooms (A{approx}C). Room A has a vertical irradiation system, Room C horizontal and Room B both vertical and horizontal. Two rings can supply beams independently to the vertical and horizontal irradiation systems. Clinical trial started on June 21 1994, after several basic biological and physics experiments lasting about 2 months. Cancer is the top cause of death in Japan since 1981, and people expect good treatment results at HIMAC. Proton and heavy ion radiotherapy has the advantage of dose ...
1995-03-01
ANALYSIS OF ACCELERATOR BASED NEUTRON SPECTRA FOR BNCT USING PROTON RECOIL SPECTROSCOPY
Energy Technology Data Exchange (ETDEWEB)
Boron Neutron Capture Therapy (BNCT) is a promising binary treatment modality for high-grade primary brain tumors (glioblastoma multiforme, GM) and other cancers. BNCT employs a boron-10 containing compound that preferentially accumulates in the cancer cells in the brain. Upon neutron capture by {sup 10}B energetic alpha particles and triton released at the absorption site kill the cancer cell. In order to gain penetration depth in the brain Fairchild proposed, for this purpose, the use of energetic epithermal neutrons at about 10 keV. Phase I/II clinical trials of BNCT for GM are underway at the Brookhaven Medical Research Reactor (BMRR) and at the MIT Reactor, using these nuclear reactors as the source for epithermal neutrons. In light of the limitations of new reactor installations, e.g. cost, safety and licensing, and limited capability for modulating the reactor based neutron beam energy spectra alternative neutron sources are being contemplated for wider implementation of this ...
1998-11-06
Energy Technology Data Exchange (ETDEWEB)
A general expression for the current-density distribution of a focused-ion beam (FIB) in the chromatic-aberration region is set up in the form of a definite integral. With the experimentally obtained ion-energy distribution of a liquid-metal ion source, its contribution to the FIB current-density distribution is estimated. Calculated results explain the wide-exponential tail of a FIB.
1987-09-01
International Nuclear Information System (INIS)
A general expression for the current-density distribution of a focused-ion beam (FIB) in the chromatic-aberration region is set up in the form of a definite integral. With the experimentally obtained ion-energy distribution of a liquid-metal ion source, its contribution to the FIB current-density distribution is estimated. Calculated results explain the wide-exponential tail of a FIB.
UK PubMed Central (United Kingdom)
For intensity modulated radiation treatment (IMRT) dose reconstruction, multileaf collimator (MLC) log files have been shown applicable for deriving delivered fluence maps. However, MLC log files are...Full Text Available
2008-11-01
UK PubMed Central (United Kingdom)
1. The antihypertensive efficacy and tolerability of a low dose combination of the angiotensin converting enzyme inhibitor ramipril (2.5 mg) and the extended release formulation of the dihydropyridine...Full Text Available
1993-10-01
Somatic and genetic effects of small doses of ionizing radiations in man
International Nuclear Information System (INIS)
Estimations on the somatic and genetic effects of small doses of ionizing radiations in Man have been proposed by the Advisory Committee on the Biological Effects of Ionizing Radiation, set up by the U.S. National Academy of Sciences. They have been published in an important report, issued in 1972, from which we briefly analyze here the Chapter dealing with the somatic effects. Small doses of raditions are expected to promote only carcinogenic effects. After a rapid survey of the human experience on which the estimations are based, as regards the latent period of cancers, the plateau region (period of high risk) and the absolute and relative risk expressed per rem, per 10"6 persons, per year, for leukaemia (having the highest risk) and for the ''other cancers''. These estimations were obtained by linear extrapolation to the 1 rem level from observations made after irradiation at relatively high dose levels and much higher ...
1976-01-01
Single-dose pharmacokinetics of ceftriaxone in healthy Chinese adults.
UK PubMed Central (United Kingdom)
The pharmacokinetics of ceftriaxone were investigated in six healthy mainland Chinese adults (four males and two females). A single 1.0-g dose was administered intravenously or intramuscularly in a...Full Text Available
1985-02-01
Risk of cancer after low doses of ionising radiation: retrospective cohort study in 15 countries
UK PubMed Central (United Kingdom)
Objectives To provide direct estimates of risk of cancer after protracted low doses of ionising radiation and to strengthen the scientific basis of radiation protection standards for environmental,...Full Text Available
2005-07-09
UK PubMed Central (United Kingdom)
AimsTo assess the tolerability and pharmacokinetic profile of single and repeat doses of the oral matrix metalloproteinase inhibitor marimastat in healthy male volunteers.Full Text Available
1998-01-01
Range and modulation dependencies for proton beam dose per monitor unit calculations
UK PubMed Central (United Kingdom)
Calculations of dose per monitor unit (D∕MU) are required in addition to measurements to increase patient safety in the clinical practice of proton radiotherapy. As in conventional photon and...Full Text Available
2009-02-01
Radiation risks for medical applications
International Nuclear Information System (INIS)
The achievements made in the field of radiation protection over the past 20 years are outlined. Risk analysis as applied to medicine is considered and genetic significant doses, genetic risks, somatic effective doses and somatic risks are discussed. (C.F.).
1980-05-31
UK PubMed Central (United Kingdom)
Low dose methotrexate has been used effectively for various rheumatic and non-rheumatic diseases. Three cases of Pneumocystis carinii pneumonia occurring during treatment of rheumatoid arthritis with...Full Text Available
1991-03-01
UK PubMed Central (United Kingdom)
BackgroundThe aim of this study was to compare and to validate different dose calculation algorithms for the use in radiation therapy of small lung lesions and to optimize the treatment...Full Text Available
UK PubMed Central (United Kingdom)
The reference medium for brachytherapy dose measurements is water. Accuracy of dose measurements of brachytherapy sources is critically dependent on precise measurement of the source–detector...Full Text Available
2010-01-01
Milk residues and performance of lactating dairy cows administered high doses of monensin
UK PubMed Central (United Kingdom)
AbstractMilk residues and performance were evaluated in lactating cows that were fed up to 10 times the recommended dose of monensin. Following an acclimatization period of 14 d, during...Full Text Available
2005-07-01
Energy Technology Data Exchange (ETDEWEB)
The purpose of this report is to summarize the assumptions, dose factors, consumption rates, and methodology used to evaluate potential radiation doses to persons who may eat contaminated wildlife or contaminated plants collected from the Hanford Site. This report includes a description of the number and variety of wildlife and edible plants on the Hanford Site, methods for estimation of the quantities of these items consumed and conversion of intake of radionuclides to radiation doses, and example calculations of radiation doses from consumption of plants and wildlife. Edible plants on the publicly accessible margins of the shoreline of the Hanford Site and Wildlife that move offsite are potential sources of contaminated food for the general public. Calculations of potential radiation doses from consumption of agricultural plants and farm animal products are made routinely and ...
1990-10-01
International Nuclear Information System (INIS)
For the risk estimate of fatal malignancies, an effective dose was proposed on the basis of the assumption that the risk should be equal whether the whole body irradiated uniformly or whether there is non-uniform irradiation. The effective dose was defined by the product of organ or tissue doses and a weighting factor representing the proportion of risk factor for a fatal malignancy resulting from organ or tissue irradiation to the total malignant factor. The risk of malignancies can be derived by multiplying the malignant significant factor by the product of the risk factor and the effective dose. For the genetic risk, a significant factor was a relative child expectancy and organ or tissue doses were gonad doses. And, for the leukemogenic risk, a significant factor was the leukemia significant factor and organ or tissue dose was mean bone ...
1980-01-01
Metabolism of iodomethane in the rat
UK PubMed Central (United Kingdom)
1. The LD50 of iodomethane orally administered to rats is 76mg./kg. body wt. but repeated daily doses of 30–50mg./kg. body wt. are without effect. 2. Oral doses of iodomethane to...Full Text Available
1966-01-01
Low-Dose, Off-Label Drotrecogin Alfa (Xigris) In Severe Sepsis
UK PubMed Central (United Kingdom)
Objective:In this article, we describe a successful low-dose, off-label usage of drotrecogin alfa (Xigris), given at 18 mcg/kg per hour, in a patient with severe sepsis who had an...Full Text Available
2008-08-01
UK PubMed Central (United Kingdom)
ObjectiveTo assess the efficacy and safety of low dose adrenaline injected subcutaneously to prevent acute adverse reactions to polyspecific antivenom serum in patients admitted...Full Text Available
1999-04-17
Long-term effects of inhaled uranyl nitrate in rats
International Nuclear Information System (INIS)
Rats were exposed to aerosols of "2"3"3U and "2"3"2U nitrate in a study of the long-term biological effects. Preliminary radiation dose estimates show lung > skeleton > kidney in each dose group.
1977-05-01
Isochron measurements of naturally irradiated K-feldspar grains
International Nuclear Information System (INIS)
The equivalent doses of K-feldspar grains in a range of grain sizes from 90 to 250#mu#m diameter were measured using a single-aliquot regenerative-dose protocol for the infrared stimulated luminescence (IRSL) signals for two samples of desert sand. The equivalent doses for each sample were compared with that for the 125-150#mu#m grains of quartz from the same samples. The results suggested that the K-feldspar equivalent doses were underestimated because of anomalous fading. Measurements of the decay of the IRSL signals following laboratory irradiation for these two samples, and an additional one from a previously published isochron study, showed anomalous fading during the period of laboratory storage. The decay rate was about 3% per decade for all samples and was independent of the grain size used. Using plots of equivalent doses for K-feldspars as a function of their calculated ...
2007-09-01
Inhibition of exercise-induced asthma by nifedipine: a dose-response study.
UK PubMed Central (United Kingdom)
1. The effect of three single doses of nifedipine on exercise-induced asthma has been examined in 11 asthmatic subjects. 2. On four separate days patients undertook 6 min of exercise on a treadmill...Full Text Available
1987-10-01
Induction of tumors by screening mammography
International Nuclear Information System (INIS)
Somatic radiation doses are recognized to be possible factors of carcinogenesis. In correctly performed mammography, however, even as screening test, the radiation dose does not reach such an order of magnitude that the benefit of the procedure as to prevention of breast cancer is called into question.
1983-01-01
Fluence-convolution broad-beam (FCBB) dose calculation
International Nuclear Information System (INIS)
IMRT optimization requires a fast yet relatively accurate algorithm to calculate the iteration dose with small memory demand. In this paper, we present a dose calculation algorithm that approaches these goals. By decomposing the infinitesimal pencil beam (IPB) kernel into the central axis (CAX) component and lateral spread function (LSF) and taking the beam's eye view (BEV), we established a non-voxel and non-beamlet-based dose calculation formula. Both LSF and CAX are determined by a commissioning procedure using the collapsed-cone convolution/superposition (CCCS) method as the standard dose engine. The proposed dose calculation involves a 2D convolution of a fluence map with LSF followed by ray tracing based on the CAX lookup table with radiological distance and divergence correction, resulting in complexity of O(N"3) both spatially and temporally. This simple algorithm is orders ...
2010-12-07
Epidemiological survey of the effects of low level radiation dose: a comparative assessment
Energy Technology Data Exchange (ETDEWEB)
This volume presents the collations tables of a six volume comparative epidemiological survey of the effects of low level radiation dose. Data are collated for the effects observed in the following irradiated groups:- Preconception irradiation, intra-uterine irradiation, childhood irradiation, adult irradiation. (UK).
1993-10-01
International Nuclear Information System (INIS)
The genetically significant dose (GSD) is an index variable which exclusively allows to describe the genetic risk in the progeny of a population due to the application of ionizing radiation and radioactive substances in one part of this population. It may result in wrong interpretation of population exposure at increasing incidence of examinations in a population involving ionizing radiation and radioactive drugs at simultaneously increasing application of alternative methods in children and adolescents owing to the fact that it indicates a downward trend although somatic exposure of this population has increased. Therefore, it is recommended to state both the GSD and the level of somatic radiation exposure of the population taken from the individual sources for the comparison and assessment of radiation exposure from various sources in future. Although the somatically significant dose constitutes the suitable variable complementary to GSD in ...
1984-06-01
ESR dosimetry of irradiated chicken legs and chicken eggs
Energy Technology Data Exchange (ETDEWEB)
Ionising radiation induces stable free radicals in chicken bones and in the shell of chicken eggs which can be detected, by the electrons spin resonance (ESR) technique, well beyond the shelf-life of the food and can be used for dosimetry. The method usually adopted to evaluate ``a posteriori`` the dose given during the ionising radiation treatment of food, is the dose additive method. To assess the dose, the ESR signal amplitude of the irradiated food (bone or egg shell in the present case) is measured and then the dose-effect relationship is obtained by re-irradiating the sample with some additive doses (usually of 1 kGy). The dose-effect curve is back-extrapolated and the initial given dose determined. At the Istituto Superiore di Sanita (ISS), Rome, Italy, a research programme was approved two years ago aimed to, (1) study new ...
1996-12-31
UK PubMed Central (United Kingdom)
PurposeTo investigate the influence of inhomogeneity corrections on stereotactic treatment plans for non-small cell lung cancer and determine the dose delivered to the PTV and OARs.Full Text Available
UK PubMed Central (United Kingdom)
IntroductionThe optimal dialysis dose for the treatment of acute kidney injury (AKI) is controversial. We sought to evaluate the relationship between renal replacement therapy (RRT)...Full Text Available
2009-01-01
A randomized-controlled trial of low-dose doxycycline for periodontitis in smokers
UK PubMed Central (United Kingdom)
Background/AimTobacco use reduces the effect of non-surgical periodontal therapy. Host-modulation with low-dose doxycycline (LDD) might favour repair and promote...Full Text Available
2007-04-01
International Nuclear Information System (INIS)
The High Flux Isotope Reactor (HFIR) located at Oak Ridge National Laboratory is one of the world's most powerful research reactors. In 1996, one year after the demise of the Advanced Neutron Source Project, the U.S. Department of Energy embarked on an aggressive program to upgrade the neutron scattering facilities at the HFIR. These upgrades, which are now in progress, include the installation of larger beam tubes, a high-performance hydrogen cold source, and additional neutron guides and neutron scattering instruments. An extensive analysis effort was performed over the past 4 yr to support the design of the modified beamlines and new user facilities and to assess the impact of the upgrades on the integrity of the existing reactor system. The results of three of these analyses are summarized here. Specifically, results are presented for analyses related to the design of the new cold neutron source (CNS), the assessment of beam tube changes on the anticipated pressure vessel lifetime, ...
2001-06-17
International Nuclear Information System (INIS)
During one year more than 40,000 items of information on radiation exposure of personnel involved in the handling of radiation sources and more than 5,000,000 items on irradiation of other people are collected in the authors' laboratory. Considerable progress in assessment of mean annual gonad dose of genetically sifnificant dose was attained by means of an algorithm for a personal computer. This simple and inexpensive system has led to a higher accuracy in the application of protective measures. (author).
1985-10-22