Body dose conversion factors for computerized tomography
International Nuclear Information System (INIS)
While there have been many experimental and calculational investigations on absorbed dose distribution in the patient resulting from conventional X-ray procedures, such data for computerized tomography (CT) are still sparse. As this diagnostic procedure has shown a rapid increase in application during recent years, we have determined absorbed dose to body organs in a human phantom resulting from CT examinations. The exposure model consists of the heterogeneous MIRD-5 phantom and a suitable Monte-Carlo method to calculate absorbed dose to organs of interest. The exposure conditions are specified according to the exposure specifications of a CT-scanner currently in use. The calculations cover the range of body tissues of interest in terms of organ absorbed ...
1980-10-31
Dose planning and dose delivery in radiation therapy
International Nuclear Information System (INIS)
A method has been developed for calibration of CT-numbers to volumetric electron density distributions using tissue substitutes of known elemental composition and experimentally determined electron density. This information have been used in a dose calculation method based on photon and electron interaction processes. The method utilizes a convolution integral between the photon fluence matrix and dose distribution kernels. Inhomogeneous media are accounted for using the theorems of Fano and O'Connor for scaling dose distribution kernels in proportion to electron density. For clinical application of a calculated dose plan, a method for prediction of accelerator output have been developed. The methods gives the number of monitor units that has to be given to obtain a certain absorbed dose to a point inside an irregular, ...
2008-08-01
International Nuclear Information System (INIS)
The purpose of this study is to evaluate the accuracy of dose calculations by three algorithms. Depth dose, OPF (Output Factor) and dose profiles were measured in a heterogeneous phantom. These values were also calculated by three algorithms of the Batho power law (BPL), Equivalent-Tissue Air Ratio (ETAR) and Convolution superposition (CS). The data were obtained for 4, 6 and 10 MV photon beams with a linear accelerator (Varian 21EX). Field size ranged from 3 x 3 cm"2 to 10 x 10 cm"2. Dose profiles of beam penumbra were also measured by a 0.125 ml ionization chamber at the point of 8, 13 and 18 cm from the surface of the phantom at intervals of 1 mm. Differences between measured and calculated depth doses were within 2% in BPL and CS, but depth doses were overestimated in ETAR. OPFs were also ...
2004-12-01
Estimation of X-rays dose in the crystals of final thickness
International Nuclear Information System (INIS)
A calculation method of the X-ray radiation dose (energy of gamma- radiation remains in the range of energies where the mechanism of photoelectric absorption is the prevailing one) absorbed in the absorbers of final thickness is suggested. Calculations of resorption of secondary radiation (characteristic fluorescences) in the substance and kinetic energy of photoelectrons caused by this resorption (it would be enough to consider one or two hard series) are presented. Calculation of the spectrum of photoelectron energy yield in TeInSe_2 monocrystal for 0.1-0.5 A range of X-ray radiation is conducted by the developed methods.
Absorbed dose and dose equivalent depth distributions for protons with energies from 2 to 600 MeV
Energy Technology Data Exchange (ETDEWEB)
Depth dose distributions for protons in the energy range from 2 to 600 MeV have been calculated by Monte Carlo and analytical methods. The dependence on energy of Maximum Dose Equivalent (MDE), quality factor and isotropic factor recommended for practical use are presented. The problems connected with regulation of maximum permissible proton fluxes are discussed. (author).
1989-01-01
28: Calculation of 3D dose distribution for photons in inhomogeneous media
International Nuclear Information System (INIS)
A method for calculation of absorbed dose distributions in three dimensions for 1-20 MeV photons is presented. The method uses convolution/superposition of photon fluence distributions with energy scattering kernels. Results for Co-60 and X-ray beams in homogeneous and inhomogeneous media are compared with measurements. Good agreement is found between calculations and measurements. 8 refs.; 3 figs.
Multicellular level dosimetry and low dose rate effects
International Nuclear Information System (INIS)
Building on the concepts of MIRD methods described by Webber, Watson and others at this Symposium on the Dosimetry of Administered Radionuclides, we will now consider how to apply these principles to several experimentally based open-quote macroclose quotes and multicellular models. Specifically, methods to calculate absorbed dose using different types of particulate emission (alpha, beta) with a variety of antibody carriers (IgG, F(ab')_2, Fab) for radioimmunotherapy (RIT) will be reviewed. Additionally, a discussion of direct measurement methods at the multicellular level will reveal the problems of tumor absorbed dose heterogeneity when applied to animal and clinical studies.
1989-09-21
Medical irradiation and the use of the 'effective dose equivalent' concept
International Nuclear Information System (INIS)
By applying the linear-dose effect relation, the weighting factors for total risks recommended by IRCP can be transformed to weighting factors for somatic effects. Another weighting factor Msub(s) has to be used which takes into account the dependence of the latent period for occurrence of malignant disease and the variation of the incidence with time. On this basis a somatically significant dose equivalent can be defined as 'the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by the various individuals', and an approximation has been derived for this. Tables are presented of the somatic effective dose equivalents calculated for different x-ray examinations for various organs and tissues. The S.E.D. equivalents have also ...
1980-03-01
International Nuclear Information System (INIS)
Techniques for reducing computation time in 3D photon dose calculations are addressed with specific emphasis given to the convolution/superposition approach. A single polyenergetic superposition model calculating absorbed dose per incident photon fluence (Gy cm"2) was developed in terms of TERMA and a total energy deposition kernel (a total point spread function). A novel approach was devised for reducing calculation time. The method, named the CF method, was based on the use of a conventional, fast model (here a modified power-law method was used) for the generation of 3D dose distributions on a fine dose matrix. Superposition calculations were carried out on a coarse matrix and calculation speed was increased simply by reducing the number of calculations. A ...
1997-08-01
International Nuclear Information System (INIS)
International standards and guidelines for calibrating high-dose dosimetry systems to be used in industrial radiation processing recommend that dose-rate effects on dosimeters be evaluated under conditions of use. This is important when the irradiation relies on high-current electron accelerators, which usually provide very high dose-rates. However, most dosimeter calibration facilities use low-intensity gamma radiation or low-current electron accelerators, which deliver comparatively low dose-rates. Because of issues of thermal conductivity and response, portable calorimeters cannot be practically used with high-current accelerators, where product conveyor speeds under an electron beam can exceed several meters per second and the calorimeter is not suitable for use with product handling systems. As an alternative, Monte Carlo calculations can give theoretical estimates of the ...
2007-08-01
Alpha-particle dose distribution effects at the cellular level
International Nuclear Information System (INIS)
Ionizing radiations that differ in number, size, and distribution of energy deposition events might be expected to cause different effects for the same absorbed dose. Furthermore, microdosimetry calculations suggest that large variations in biological effectiveness might be expected for internally deposited alpha-emitting radionuclides for the same absorbed dose, depending upon the specific activity and spatial distribution of the sources in tissue. The study described in this article was designed to demonstrate these phenomena in vitro. Cultured Chinese hamster ovary (CHO-K1 BH4) cells were exposed in vitro to inert, insoluble ceramic microspheres in zirconium dioxide labeled with "2"3"9Pu. The average exit energy of the 5.15 MeV alpha particle was calculated to be 4.3 MeV. Exposure times varied from four to seven hours to achieve the desired ...
1985-02-01
Clinical application of dosimetry in electron beam therapy
International Nuclear Information System (INIS)
In everyday radiotherapy we must carry out the determination of absorbed dose measurement according to JARP's protocol. We explained an outline of JARP's 1974 and 1986 protocol in electron beam therapy, and mentioned it about the matter that should examined. To use it easily in clinic, a simplified procedure based on precisely to JARP's 1986 protocol is practical, the character of this procedure settles briefly the determination of mean incident energy of electron beams and get ready to table of ionization to absorbed dose conversion factor for various ionization chamber. Also, this procedure almost not influence on the accuracy of determination. We described systematically practical procedure for requisite absorbed dose calculation in a patient in electron beam therapy. (author).
Calculated fluence spectra at neutron therapy facilities
International Nuclear Information System (INIS)
The Monte Carlo transport codes LAHET and MCNP were used to calculate energy fluence spectra at three neutron therapy facilities. The results compare very favourably with measured data. Kerma spectra and the ratio of ICRU muscle tissue kerma to A-150 kerma, along the carbon to oxygen kerma ratio, were determined. Absorbed dose rate calculations are in reasonable agreement with measured values. Use of these codes to study modifications to existing therapy beams is briefly discussed. (author).
1995-11-13
Determination of absorbed dose in a patient irradiated by beams of x or gamma rays in radiotherapy procedures
1976-01-01
Dosimetry of iodine-123 iomazenil in humans
International Nuclear Information System (INIS)
The distribution of the central benzodiazepine receptor specific ligand iodine-123 iomazenil was investigated in seven human adults from whole-body scans, blood samples and urine collected up to 24 h after injection. Using 12 source organs, the MIRD method was applied to calculate the absorbed radiation dose of the radioligand in various organs. The urinary bladder wall (0.15 mGy/MBq), lower large intestinal wall (0.071 mGy/MBq) testes (0.044 mGy/MBq) and upper large intestined wall (0.038 mGy/MBq) received the highest absorbed doses. The average effective dose equivalent of "1"2"3I-IBZM for adults was estimated to be 0.033 mSv/MBq. (orig.).
The result of Alanine/ESR dosimetry at Wolsung unit 1
International Nuclear Information System (INIS)
It needs accurate estimation of radiation level for verifying machinery and cable in Nuclear Power Plant. Therefore, in this study, we used ESR(Electron Spin Resonance) system for estimate dose of Alanine dosimeter. Alanine/ESR dosimetry, already known as a dosimetric method in medical and industrial field, was applied to estimate dose quantity at cable locations within a nuclear power plant as a part of equipment qualification program. Alanine/ESR dosimetry of absorbed dose range is 1 - 100 KGy. The alanine dosimeter is not significantly affected by temperature and fading is limited to 1% per year. The alanine dosimeters were fixed on the targeted cable or nearest position to measure dose quantity to get accurate value. Alanine dosimeters were scanned by commercially used two different ESR systems, e-scan and EMX series for alanine dosimeters. To estimate more accurate ...
2008-10-01
Optimization of segment weight using simulated dynamics algorithm for beamlet-based IMRT
International Nuclear Information System (INIS)
With accurate calculation algorithms in inverse planning for beamlet-based intensity modulated radiotherapy (IMRT), it takes time to calculate the dose matrix, which represents the dose distribution of each beamlet element to each voxel for unit fluence. To reduce the calculation time, coarse or approximate algorithms are often a choice, but this results in a final dose distribution that cannot reflect the real value. In addition, it is necessary to test if a coarse algorithm is capable of calculating the dose matrix of beamlets. In this work, simulated dynamics optimization algorithm was applied to optimize the segment weight to minish the dose error from the dose matrix calculation. After calculating the dose matrix ...
2007-08-01
Energy Technology Data Exchange (ETDEWEB)
The importance of cellular dosimetry in both diagnostic and therapeutic nuclear medicine is becoming increasingly recognized. Experimental range-energy relations for electrons and alpha particles, along with derived geometric reduction factors, are used to calculate cellular absorbed fractions for these radiations. The resulting absorbed fractions are employed to calculate cellular S-values for several radionuclides. Cellular absorbed fractions for monoenergetic electron sources with energies ranging from 0.1 keV to 1 MeV, distributed uniformly in the source region, are calculated for several target {l_arrow} source combinations including cell{l_arrow}cell, cell{l_arrow}cell surface, nucleus{l_arrow}nucleus, nucleus {l_arrow}cytoplasm and nucleus {l_arrow}cell surface. Similar data are also provided for monoenergetic alpha particle sources with energies ranging ...
1994-02-01
Photon dosimetry using plastic scintillators in pulsed radiation fields
Energy Technology Data Exchange (ETDEWEB)
Simulations and experiments have been carried out to explore using a plastic scintillator as a dosimetry probe in the vicinity of a pulsed bremsstrahlung source in the range 4 to 20 MeV. Taking advantage of the tissue-equivalent properties of this detector in conjunction with the use of a fast digital signal processor near real-time dosimetry was shown to be possible. The importance of accounting for a broad energy electron beam in bremsstrahlung production, and photon scattering and build-up, in correctly interpreting dosimetry results at long stand-off distances is highlighted by comparing real world experiments with ideal geometry simulations. Close agreement was found between absorbed energy calculations based upon spectroscopic techniques and calculations based upon signal integration, showing a ratio between 10 MeV absorbed dose to 12 MeV absorbed ...
2007-04-01
Analysis on Dose Distribution in Heterogeneous Condition for Narrow 6 MV X-ray Beams
International Nuclear Information System (INIS)
Advanced modality of high-precision radiotherapy fulfilled by a composition of large numbers of small field beams called 'beamlets' can be achieved via nonuniform intensity fluencies. In case of radiation measurements and calculations with narrow high-energy photon beams, however, an accurate two-dimensional dosimetry is a challenging task due to dosimetrically unfavorable phenomena such as dramatic changes of the dose at the field boundaries, dis-equilibrium of the electrons resulting from larger detector volume, and non-uniformity between the detector and the phantom materials. Meanwhile, with the advantages of high spatial resolution and wide range of absorbed doses, there is a growing demand of GAFCHROMICat..EBT film to confirm delivered dose distribution. Especially, the effects from the material differences between the phantom and the film can be minimized in the heterogeneous ...
2010-10-01
Absorbed dose and dose reduction in mammography
International Nuclear Information System (INIS)
First, absorbed dose at entrance surface was measured in routine mammography. Secondly, a possibility of dose reduction after introduction of Fuji computed radiography (FCR) system was examined. In a total of 350 mammographic studies including craniocaudal and medilateral projections, average thickness of compressed breast was less than 4 cm and most frequently recorded absorbed dose was 0.2-0.3 cGy (200-300 mrad). Minimum dose to obtain clinically acceptable mammograms in FCR system was estimated by comparing image quality of routine versus reduced dose studies. It was concluded that absorbed dose could be reduced to 1/4 of routine dose without creating significant drawback in diagnosis. (author).
1986-01-01
Retrospective individual dosimetry using luminescence and EPR after radiation accidents
International Nuclear Information System (INIS)
In areas where radiation dose monitoring has not been performed, it is essential to use material available in the environment be able to rapidly assess doses to individuals for immediate emergency medical care or for general estimation of the radiological consequences. It was shown that certain types of telephone cards containing microchips have the potential to be used as individual radiation dosimeters in emergency situations to detect doses over 250 mGy by luminescence measurements. In order to understand the dosimetric properties of chip cards, the components obtained from INFINIEON Company at various stages of production were used for luminescence measurements. It is found that the protecting layer used above the chips so called 'globe top' is the main source of radiation induced signal in chip cards. The globe top produced by INFINIEON at that stage is found to contain SiO2 and Epoxy. In order to improve the ...
International Nuclear Information System (INIS)
The MCNPE-BO and MCNP4 Monte Carlo electron-photon codes were used to calculate the dose equivalent per unit fluence at various depths in tissue-equivalent slab phantoms for broad parallel beams of monoenergetic electrons with energies from 50 keV to 10 MeV. The study was carried out in the framework of the activities of a ICRP/ICRU Joint Task Group with the support of EURADOS WG4 (Numerical Dosimetry). Some preliminary results and comparisons as well as a general discussion on the performances of the codes are presented, demonstrating quite a satisfactory agreement among the results obtained using the two codes and those of other authors. (author).
International Nuclear Information System (INIS)
A number of procedures in diagnostic radiology and cardiology make use of long exposures to x-rays from fluoroscopy units. Although numerous studies have been performed to measure or calculate skin dose from these procedures, there have only been a handful of studies to determine the dose to the other organs. This thesis was focused on devising a method to calculate the absorbed dose to underlying tissues and organs. The work was performed in several stages. First, a commercial convolution/superposition-based treatment planning system used in radiation oncology was modified and complemented to make it usable with the low energies of x-rays used in diagnostic radiology. This required generation of energy deposition kernels in the kilovoltage energy range. The kernels were generated using the EGS4 Monte Carlo system of codes and added to the treatment planning ...
2001-03-01
Energy Technology Data Exchange (ETDEWEB)
Faced with increasing indications for the use of iodine-131 labelled lipiodol in the treatment of hepatocellular carcinoma (HCC), it appears essential to develop an individualized dosimetrY so we can predict the potential effectiveness of this treatment and adjust the activity to be injected. We developed a dosimetric protocol based on imagery and dedicated to calculation of the tumoral dose during the treatment of hepatocellular carcinoma by iodine-131 labelled lipiodol. This concept was developed on a SPECT- CT gantry, and integrates corrections for the phenomena of attenuation, diffusion and dead time. The dose is calculated according to the formalism proposed by the Medical Internal Radiation Dose Committee (MIRD). This protocol was applied to a series of 41 patients in the framework of a retrospective study. The results obtained in terms of biodistribution are compatible with ...
2006-12-15
Determinations of organ or tissue doses to survivors in Hiroshima and Nagasaki
International Nuclear Information System (INIS)
For the purpose of risk estimates from radiation carcinogenesis including leukemogenesis and radiation genetic effects, the biological significant dose is not the tissue kerma in air but the absorbed dose in organ or tissue with respect to carcinogenic and leukemogenic effects or genetic effects. In order to estimate organ or tissue dose from the tissue kerma in air, a ratio of the organ or tissue dose to the tissue kerma in air for survivors in Hiroshima and Nagasaki was calculated with the aid of the Snyder's mathematical phantoms constructed so as to simulate the body shape of survivors aged 5, 10 years old and adult at the time of atomic bomb detonations. The ratios were corrected for the angular distribution of atomic bomb radiations, assuming an anisotropic angular distribution for the survivors exposed to the atomic bombs in open air and the isotropic ...
1980-01-01
Bomb "1"4C and human radiation burden
International Nuclear Information System (INIS)
Following the publication (Stenhouse and Baxter, Nature; 267:828 (1977)) of the levels of bomb "1"4C and the residence times of carbon in the human body, excess radiation burdens from this radioisotope are evaluated under the assumption that no radiation dose, however small, can be regarded as entirely harmless biologically. The estimated annual absorbed dose attributable to "1"4C both natural and man-made for 1953-1973 and similar predicted figures for 1975-2025 are shown graphically. The cumulated doses to gonads (over 30 yr) and to bone marrow and bone-lining cells (over 60 yr) and also estimates of the biological damage to reproductive cells from "1"4C #beta#-irradiation (30 yr accumulated dose) are presented. It is concluded from both genetic and somatic considerations, that the potential human radiation burden due to artificially produced "1"4C calculated ...
Somatic and genetic radiation exposure of the patient in digital subtraction angiography (DSA)
International Nuclear Information System (INIS)
The somatic and genetic radiation exposure of patients undergoing Digital Subtraction Angiography (DSA) and traditional Film Arteriography (FA) of cranial, cervical, thoracic and abdominal vascular territories are compared. The radiation doses absorbed within the critical organs - red bone marrow, lung, thyroid gland and female breast - and in the gonads were measured using an anthropomorphic Alderson phantom. A Somatic Dose Index was calculated in order to estimate the somatic radiation risk. The somatic radiation exposure depends upon the location of the critical organs with respect to the entrance site of the x-ray beam, and can be reduced by an appropriate choice of the angiographic projection. Under this condition, the radiation exposure of the patient during DSA can be lower than during FA. For renal DSA an a.p. projection, the use of an abdominal compression device and careful caudal shielding of ...
1986-01-01
Energy Technology Data Exchange (ETDEWEB)
Graft copolymerization of sodium styrene sulfonate (SSS) onto electron beam (EB) irradiated poly(vinylidene fluoride) (PVDF) films was investigated to find out a simple preparation process for sulfonic acid proton exchange membranes with respect to monomer concentration, absorbed dose, temperature, film thickness and storage time. The reaction order of the monomer concentration and absorbed dose of grafting was found to be 2.84 and 1.20, respectively. The overall activation energy for graft copolymerization reaction was calculated to be 11.36 kJ/mol. The initial rate of grafting was found to decrease with an increase in the film thickness. The trapped radicals in the irradiated PVDF films remained effective in initiating the reaction without considerable loss in grafting level up to 180 days, when stored under -60 {sup o}C. The presence and distribution of polystyrene sulfonate ...
2011-01-15
Energy Technology Data Exchange (ETDEWEB)
Several short-lived, high-energy beta emitters are being proposed as the radionuclide components for molecular-targeted potential cancer therapeutic agents. The laboratory mice used to determine the efficacy of these new agents have organs that are relatively small compared to the ranges of these high-energy particles. The dosimetry model developed by Hui et al. was extended to provide realistic beta-dose estimates for organs in mice that received therapeutic radiopharmaceuticals containing 90Y, 188Re, 166Ho, 149Pm, 64Cu, and 177 Lu. Major organs in this model included the liver, spleen, kidneys, lungs, heart, stomach, small and large bowel, thyroid, pancreas, bone, marrow, carcass, and a 0.025-g tumor. The study as reported in this paper verifies their results for 90Y and extends them by using their organ geometry factors combined with newly calculated organ self-absorbed fractions from PEREGRINE and MCNP. PEREGRINE and ...
2005-08-01
A somatic dose index for diagnostic radiology
International Nuclear Information System (INIS)
Irradiation of the human body in diagnostic X-ray procedures results in different absorbed doses in the various body organs. A somatic dose index in formulated by applying the relative sensitivity of the human to each of the most important somatic effects and utilizing the absorbed dose in the affected organs. This quantity is used to convey a cumulative somatic impact and is computed for common radiographic views in diagnostic radiology as a function of beam quality for a nominal IR entrance exposure. Using typical X-ray beam qualities and exposures, the frequency of the various radiographic views that make up an examination and the frequencies of the various examinations in the national population, illustrative examples of the application of the somatic dose index are presented. (author).
1978-01-01
Energy Technology Data Exchange (ETDEWEB)
Gel dosimetry is a new dosimetry method applied in radiation therapy. Gel dosimeters consist of a radiation sensitive gel, which can integrate absorbed doses from several radiation sources or beams. The dose to the gel can be evaluated by magnetic resonance imaging (MRI), a procedure that is the focus of the present thesis. A robust tool for the evaluation of the nonuniformity in MRI has been developed, the Deviation Image method. Unlike previously presented methods, the Deviation Image method includes all nonuniformity variations across a phantom surface and is insensitive to stochastic noise. Methods for the estimation of stochastic noise were analyzed in terms of sensitivity to nonuniformities. A method that averages the stochastic noise level over five regions over the phantom surface, and a method that assesses the stochastic noise level from the background, were found to be the methods of choice. Pronounced MR image ...
2001-03-01
Ultraviolet radiation in Finland
Energy Technology Data Exchange (ETDEWEB)
Solar ultraviolet radiation is damaging for living organisms due to its high energy pro each photon. The UV radiation is often separated into three regions according to the wavelength: UVC (200-280 nm), UVB (280-320 nm) and UVA (320-400 nm). The most hazardous part, UVC is absorbed completely in the upper atmosphere by molecular oxygen. UVB radiation is absorbed by atmospheric ozone partly, and it is reaching Earth`s surface, as UVA radiation. Besides atmospheric ozone, very important factors in determining the intensity of UVB radiation globally are the solar zenith angle and cloudiness. It may be calculated from global ozone changes that the clear-sky UVB doses may have enhanced by 10-15 % during spring and 5-10 % during summer at the latitudes of Finland, following the decrease of total ozone between 1979-90. The Finnish ozone and UV monitoring activities have become a part of international ...
1996-12-31
Energy Technology Data Exchange (ETDEWEB)
Apoptosis is a pattern of cell death involving nuclear pycnosis, cytoplasmic condensation, and karyorrhexis. Apoptosis induced by continuous irradiation with gamma rays (externally given by a 137Cs source) or with beta rays (from tritiated water injected ip) was quantified in the crypts of two portions of mouse bowel, the small intestine and descending colon. The time-course change in the incidence of apoptosis after each type of radiation could be explained on the basis of the innate circadian rhythm of the cells susceptible to apoptotic death and of the excretion of tritiated water (HTO) from the body. For 6-h continuous gamma irradiation at various dose rates (0.6-480 mGy/h) and for 6 h after injection of HTO of various radioactivities (0.15-150 GBq per kg body wt), the relationships between dose and incidence of apoptosis were obtained. Survival curves were then constructed from the curves for dose vs incidence of ...
1989-04-01
Electron Beam and Gamma Radiolysis of Solid-State Metoclopramide
British Library Electronic Table of Contents (United Kingdom)
Purpose Study the radiolysis of solid-state metoclopramide hydrochloride at various absorbed doses. Elucidate the structure of the degradation products to gain information on the radiolysis mechanisms. Methods Solid-state metoclopramide samples were irradiated at several doses with gamma rays and high-energy electrons to evaluate the influence of the dose rate. High-performance liquid chromatography with a diode array detector was used to measure the chemical potency as a function of the absorbed dose and to quantify the degradation products. The characterization of degradation products was performed by liquid chromatography/atmospheric pressure chemical ionization/tandem mass spectrometry. Results The degradation of solid-state metoclopramide after irradiation was negligible. No qualitati...
2006-01-01
Deterministic calculations of radiation doses from brachytherapy seeds
International Nuclear Information System (INIS)
Brachytherapy is used for treating certain types of cancer by inserting radioactive sources into tumours. CDTN/CNEN is developing brachytherapy seeds to be used mainly in prostate cancer treatment. Dose calculations play a very significant role in the characterization of the developed seeds. The current state-of-the-art of computation dosimetry relies on Monte Carlo methods using, for instance, MCNP codes. However, deterministic calculations have some advantages, as, for example, short computer time to find solutions. This paper presents a software developed to calculate doses in a two-dimensional space surrounding the seed, using a deterministic algorithm. The analysed seeds consist of capsules similar to IMC6711 (OncoSeed), that are commercially available. The exposure rates and absorbed doses are computed using the Sievert integral and ...
2003-08-17
Report of the IPSM working party on low- and medium-energy x-ray dosimetry
Energy Technology Data Exchange (ETDEWEB)
New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).
1991-08-01
Report of the IPSM working party on low- and medium-energy x-ray dosimetry
International Nuclear Information System (INIS)
New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).
1991-01-01
A water calorimeter for high energy x-rays and electrons
The current primary standards at NPL for the measurement of absorbed dose to water in high energy photon and electron beams are graphite calorimeters. However, the quantity of interest in radiation dosimetry is absorbed dose to water. Therefore, a new absorbed dose to water standard based on water calorimetry has been developed for use in high energy photon and electron beams. The calorimeter operates at 4 deg C, with temperature control being provided by liquid cooling. The sealed glass inner vessel of the calorimeter was designed to minimise the effect of non-water materials on the measurement of absorbed dose. The temperature sensing thermistor probes were designed and constructed so that glass is the only material in contact with high purity water inside the vessel. Initial measurements of ...
2000-01-01
Examples are used to demonstrate that a shift in the point of emphasis is necessary with regard to radiation hazard in medicinal X-ray diagnosis. The parameters employed in this study to calculate somatic dose (SD) and somatically significant dose (SSD) m...
1980-01-01
Preparation of wood-polymer composites using radiation
International Nuclear Information System (INIS)
Wood-polymer composites (WPC) have been prepared of pinewood with different monomers using Gamma radiation: acrylamide, butyl acrylate, butyl methacrylate, styrene, acrylonitrile, and polyester. The polymer loading was determined as a function of monomer concentration and absorbed dose. The data show that polymer loading increases by increasing the monomer concentration. In two cases, BMA and polyester, the polymer loading decreases at high concentrations. This can be explained by the increase of the viscosity. Thus the diffusion of the compound into bulk would be slower. The absorbed dose seems to play a positive role in enhancing the polymer loading by increasing the dose. The mechanical properties, tensile and compression strength, have been improved in the most cases for all monomer concentrations or absorbed doses. Using polyester there ...
1976-11-25
International Nuclear Information System (INIS)
Full text: A semiempirical algorithm for absorbed dose calculation at off-axis points in irregular beams was implemented. It is well known that semiempirical methods are very useful because of their easy implementation and its helpfulness in dose calculation in the clinic. These methods can be used as independent tools for dosimetric calculation in many applications of quality assurance. However, the applicability of such methods has some limitations, even in homogeneous media, specially at off axis points, near beam fringes or outside the beam. Only methods derived from tissue-air-ratio (TAR) or scatter-maximum-ratio (SMR) have been devised for those situations, many years ago. Despite there have been improvements for these manual methods, like the Sc-Sp ones, no attempt has been made to extend their usage at off axis points. In this work, a semiempirical ...
2008-10-19
International Nuclear Information System (INIS)
Full text: Optically stimulated luminescence (OSL) dating of individual sand-sized grains of quartz has advanced significantly over the past decade opening up new vistas in luminescence geochronology. Today, single-grain OSL dating can be used to constrain the burial ages of many deposits, including fluvial sediments, glaciofluvial material and archaeological sediments. It also provides a means of examining the stratigraphic integrity of archaeological sites where sediment mixing might have occurred. An OSL age is calculated by dividing the burial dose (the dose absorbed by the grain since it was last exposed to sunlight) by the environmental dose rate (the rate of supply of ionizing radiation to the grain over the period of burial). To obtain reliable OSL ages, therefore, an accurate estimate of the dose rate is required for each sample. Here we describe our ...
2008-04-13
Energy Technology Data Exchange (ETDEWEB)
The performance of PAN-based composite absorbers was evaluated in dynamic experiments at flow rates ranging from 25--100 bed volumes (BV) per hour. Composite absorbers with active components of ammonium molybdophosphate (AMP) PAN and K-Co ferrocyanide (KCoFC) PAN were used for separating Cs from a 1 M HNO{sub 3} + 1 M NaNO{sub 3} + 2 {times} 10{sup {minus}5} M CsCl acidic simulant solution. KCoFC-PAN and two other FC-based composite absorbers were tested for separating Cs from alkaline simulant solutions containing 0.01 M to 1 M NaOH and 1 M NaNO{sub 3} + x {times} 10{sup {minus}4} M CsCl. The efficiency of the Cs sorption on the AMP-PAN absorber from acidic simulant solutions was negatively influenced by the dissolution of the AMP active component. At flow rates of 50 BV/hr, the decontamination factor of about 10{sup 3} could be maintained for treatment of 380 BV of the feed. With the KCoFC-PAN ...
1996-05-01
Dosimetry in dental radiology. Dentascan spiral CT versus panoramic radiography
International Nuclear Information System (INIS)
The study compares the doses absorbed by the dentomaxillary area in spiral CT and panoramic examinations. The dose measurements demonstrate that patients receive smaller doses with panoramic radiography than with spiral CT with Dentascan. After following for some variations from instrumental differences, they are in substantial agreement with literature data. Further investigations are needed considering the radiobiological risk related to the growing spread of Dentascan examinations.
1999-05-01
Tumour control probability (TCP) for non-uniform activity distribution in radionuclide therapy
Energy Technology Data Exchange (ETDEWEB)
Non-uniform radionuclide distribution in tumours will lead to a non-uniform absorbed dose. The aim of this study was to investigate how tumour control probability (TCP) depends on the radionuclide distribution in the tumour, both macroscopically and at the subcellular level. The absorbed dose in the cell nuclei of tumours was calculated for {sup 90}Y, {sup 177}Lu, {sup 103m}Rh and {sup 211}At. The radionuclides were uniformly distributed within the subcellular compartment and they were uniformly, normally or log-normally distributed among the cells in the tumour. When all cells contain the same amount of activity, the cumulated activities required for TCP = 0.99 (A-tilde{sub TCP=0.99}) were 1.5-2 and 2-3 times higher when the activity was distributed on the cell membrane compared to in the cell nucleus for {sup 103m}Rh and {sup 211}At, respectively. TCP for {sup 90}Y was not ...
2008-08-21
Optical effects of fine-particle carbon on urban atmospheres
Energy Technology Data Exchange (ETDEWEB)
The effects of fine-particle C, such as diesel soot, on the optical properties of urban haze in the visible wavelength range were explored to determine the dominant effects and to see if simple parameters (such as visual range in green) provide an adequate measure of these effects. It is known that fine-particle C absorbs more strongly in the blue than in the red, so that when it is mixed with a white pigment, the resulting gray can appear somewhat brown. The possibility of a similar effect in urban hazes was investigated, but found not to occur. When the sun is overhead, the near-horizon sky chromaticities caused by mixtures of fine-particle C and non-absorbing aerosol can also be produced by non-absorbing aerosols alone. It is shown that absorbing aerosol will darken the horizon sky, and a simple equation for the radiance of the horizon sky is derived. The effect of absorbing ...
1986-01-01
Tertiary-Butanol: A toxicological review
British Library Electronic Table of Contents (United Kingdom)
Tert-Butanol is an important intermediate in industrial chemical synthesis, particularly of fuel oxygenates. Human exposure to tert-butanol may occur following fuel oxygenate metabolism or biodegradation. It is poorly absorbed through skin, but is rapidly absorbed upon inhalation or ingestion and distributed to tissues throughout the body. Elimination from blood is slower and the half-life increases with dose. It is largely metabolised by oxidation via 2-methyl-1,2-propanediol to 2-hydroxyisobutyrate, the dominant urinary metabolites. Conjugations also occur and acetone may be found in urine at high doses. The single-dose systemic toxicity of tert-butanol is low, but it is irritant to skin and eyes; high oral doses produce ataxia and hypoactivity and repeated exposure can induce dependence...
2010-01-01
Mammary carcinogenesis in the rat after low-dose irradiation
International Nuclear Information System (INIS)
Carcinogenesis is now generally recognized to be an important detrimental effect in man after low dose irradiation. The carcinogenic action of ionizing radiation is clearly demonstrated after exposure to relatively high doses (in excess of 0.5 Gy) but for lower dose levels reliable direct observations are not available. With the introduction of special protocols for the performance of large scale screening programs by mammography the average absorbed dose in glandular tissue in the average breast can be restricted to a value of 3 mGy per mammogram. The risk for tumor induction after exposure to these low doses can never be established from human epidemiology. In order to investigate the risk of repeated exposure to small dose of ionizing radiation the induction of mammary tumors has been investigated in rats of the WAG/Rij strain after ...
1992-07-12
Energy Technology Data Exchange (ETDEWEB)
Natural radioactive materials under certain conditions can reach hazardous radiological levels. The natural radionuclide ({sup 238}U, {sup 232}Th, {sup 40}K) contents of rock samples at various locations in the North Tushki area were investigated using gamma-spectrometric analysis. Estimates of the measured radionuclide content have been made for the absorbed dose rate of gamma radiation. The equivalent radium (R{sub eq}) and the external hazard index (H{sub ex}) which resulted from the natural radionuclides in soil are also calculated and tabulated. The studied samples have been collected from various rock exposures in the North Tushki area. The distribution of major oxides, U and Th were studied. It is found that the enrichment and depletion of the major oxides are mainly due to the effect of hydrothermal alteration, which caused mobility of some major oxides, which increases some elements and decreases others. It is ...
2002-09-01
International Nuclear Information System (INIS)
The decree refers to conditions of irradiation of food and its components for radappertization and radurization using gamma radiation from cobalt 60 or cesium 137, X radiation or electron beam up to maximum total medium absorbed dose 10 kGy.
2003-03-04
Synthesis and PET imaging of the benzodiazepine receptor tracer [N-methyl-"1"1C]iomazenil
International Nuclear Information System (INIS)
The central benzodiazepine receptor tracer [N-methyl-"1"1C]iomazenil (Ro 16-0154) was synthesized by alkylation of the desmethyl precursor noriomazenil with ["1"1C]methyl iodide. The ["1"1C]CH_3I (prepared by reduction of ["1"1C]CO_2 with LiAlH_4 followed by reaction with HI) was reacted with noriomazenil inN,N -dimethylformamide and Bu_4N"+OH"- for 1 min at 80 deg. C and purified by HPLC (C_1_8, 34% CH_3CN/H_2O, 7 mL/min). The product was obtained with synthesis time 35 #+-# 5 min (mean #+-# SD, n = 7), radiochemical yield (EOB) 36 #+-# 16%, radiochemical purity 99 #+-# 1%, and specific activity 5100 #+-# 2800 mCi/#mu#mol. Absorbed radiation doses were calculated from previously acquired human biodistribution data. The urinary bladder wall received the highest dose (0.099 mGy/MBq) for 4.8 h voiding interval and the effective dose equivalent was 0.015 mSv/MBq. After i.v. injection ...
1995-07-01
Energy Technology Data Exchange (ETDEWEB)
Molybdenum is an essential element for living organisms. Moreover its radionuclides may represent an incorporation risk for members of the public and/or radiation workers after a nuclear accident or a release of radioactive materials. However, only few reliable data on Mo biokinetics in humans were available. The results of recent tracer kinetic investigations with stable isotopes have shown several differences from the ICRP data with regard to the processes of intestinal absorption and of excretion. As a consequence, the dose coefficients calculated with a revised biokinetic model deviate from the ICRP estimates. By ingestion of {sup 99}Mo radionuclides with solid food, for example, the dose to the colon may be higher of a factor up to 1 order of magnitude, due to the fraction of non-absorbed material which traverses the gastro-intestinal tract. (orig.) [Deutsch] Molybdaen ist einerseits ein fuer ...
1998-12-31
Energy Technology Data Exchange (ETDEWEB)
An emergency shutdown system for high-temperature gas-cooled pebble-bed reactors is proposed in addition to the common absorber rod shutdown system. This system is based on the strongly absorbing effect of small boronated graphite spheres (called KLAK), which trickle in case of emergency by gravity from the top reflector into the reactor core. The inner reflector of the Siemens-Argonaut reactor was substituted by an assembly of spherical Arbeitsgemeinschaft Versuchsreaktor fuel elements, and the shutdown effect was examined by installing well-defined KLAK nests inside this assembly. The purpose was to develop and prove a calculational procedure for determining criticality values for assemblies of large fuel spheres and small absorbing spheres.
1987-09-01
Radiation dosimetry of "1"1"1In-oxinate labelled leucocytes
International Nuclear Information System (INIS)
The patients studied were referred for routine abscess localization with indium-111 labelled autologous leukocytes. One series (n=15) was studied at 1 day after reinjection of labelled cells and a second series (n=9) was studied between 4 hours and 4 days after reinjection of labelled cells. The leukocytes were isolated by a gravity sedimentation method and labelled with In-111 oxinate according to Roevekamp and co-workers. The labelled cell suspension administered to the patient contained between 11 and 15 MegaBq (300-400 microCi). The indium-111 concentration in the liver and spleen was quantitated using a scintillation camera and an on-line computer system. Phantom studies were carried out to obtain conversion factors from geometric mean counts to MegaBq of activity for both liver and spleen. Once determined, the amount of activity in liver and spleen was corrected for physical decay of In-111 and expressed as a percentage of the administered activity. Additionally in the 2nd series ...
1982-06-25
A two-stage sequential linear programming approach to IMRT dose optimization
UK PubMed Central (United Kingdom)
The conventional IMRT planning process involves two stages in which the first stage consists of fast but approximate idealized pencil beam dose calculations and dose optimization and the second...Full Text Available
2010-02-07
CRC handbook of nuclear reactors calculations. Vol. III
International Nuclear Information System (INIS)
This handbook breaks down the complex field of nuclear reactor calculations into major steps. Each step presents a detailed analysis of the problems to be solved, the parameters involved, and the elaborate computer programs developed to perform the calculations. This book bridges the gap between nuclear reactor theory and the implementation of that theory, including the problems to be encountered and the level of confidence that should be given to the methods described. Volume III: Control Rods and Burnable Absorber Calculations. Perturbation Theory for Nuclear Reactor Analysis. Thermal Reactors Calculations. Fast Reactor Calculations. Seed-Blanket Reactors. Index.
Range and modulation dependencies for proton beam dose per monitor unit calculations
UK PubMed Central (United Kingdom)
Calculations of dose per monitor unit (D∕MU) are required in addition to measurements to increase patient safety in the clinical practice of proton radiotherapy. As in conventional photon and...Full Text Available
2009-02-01
UK PubMed Central (United Kingdom)
BackgroundThe aim of this study was to compare and to validate different dose calculation algorithms for the use in radiation therapy of small lung lesions and to optimize the treatment...Full Text Available
27: Development of a convolution/superposition method for photon beams
International Nuclear Information System (INIS)
The implementation of the convolution/superposition method in real dose planning situations is considered. The modelling of photon spectra, the use of patient and treatment setup information, and the calculation of the photon energy released in a patient are detailed. A comparison is made between the approaches of calculating the relative dose directly and using a factor derived from measurements to correct the calculated relative dose. 13 refs.; 7 figs.
Fluence-convolution broad-beam (FCBB) dose calculation
International Nuclear Information System (INIS)
IMRT optimization requires a fast yet relatively accurate algorithm to calculate the iteration dose with small memory demand. In this paper, we present a dose calculation algorithm that approaches these goals. By decomposing the infinitesimal pencil beam (IPB) kernel into the central axis (CAX) component and lateral spread function (LSF) and taking the beam's eye view (BEV), we established a non-voxel and non-beamlet-based dose calculation formula. Both LSF and CAX are determined by a commissioning procedure using the collapsed-cone convolution/superposition (CCCS) method as the standard dose engine. The proposed dose calculation involves a 2D convolution of a fluence map with LSF followed by ray tracing based on the CAX lookup table with radiological distance and divergence correction, resulting in ...
2010-12-07
Patient doses from medical uses of x-rays
International Nuclear Information System (INIS)
A survey to determine the annual genetically significant dose and mean bone-marrow dose to the Australian population from radiological procedures has been undertaken. For diagnostic radiology the following were carried out: determination of the frequency of a procedure; measurement of patient doses using TLD and processing of data and calculation of gonadal and bone-marrow doses.
1981-01-01
INTRINSIC DOSIMETRY: A POTENTIAL NEW TOOL FOR NUCLEAR FORENSICS INVESTIGATIONS
International Nuclear Information System (INIS)
Thermoluminescence (TL) dosimetry was used to measure dose effects on the raw stock material of borosilicate container glass from different geographical locations. Effects were studied at times up to 60 days post-irradiation at doses from 0.15 to 20 Gy. The minimum detectable dose using this technique was estimated to be 0.15 Gy which is roughly equivalent to a 24 hr irradiation 1 cm from a 50 ng source of 60Co. Two peaks were identified in the TL glow curve, a relatively unstable peak around 125 C and a more stable peak around 225 C. Differences in TL glow curve shape and intensity were also observed for the glasses from different geographical origins. We investigate radiation induced defects in glass to further develop the technique of intrinsic dosimetry - the measurement of the total absorbed dose received by the walls of a container holding radioactive material. Intrinsic ...
2010-07-11
International Nuclear Information System (INIS)
Electron beams as a source of directed energy are under study at the Lawrence Livermore National Laboratory (LLNL). An intense 10-kA, 50-MeV, 50-ns full-width half-maximum, pulsed electron beam is generated by the prototype Advanced Test Accelerator (ATA) at the Laboratory's Site 300. Whenever the electron beam is stopped in materials, intense radiation is generated. Estimates based on available data in the literature show that for materials such as lead, photon radiation (x ray, gamma, bremsstrahlung) levels can be as large as 10"4 roentgens per pulse at 1 m in the zero-degree direction (i.e., the electron-beam direction). Neutrons, which are emitted isotropically, are produced at a level of 10"1"3 n/m"2 per pulse. Depending upon the number of pulses and the shielding geometry, the accumulated dose is potentially lethal to personnel and potentially damaging to instrumentation that may be used for diagnostics. To provide shielding for minimizing the risk of ...
Coloring of cultured pearls by gamma-rays irradiation
International Nuclear Information System (INIS)
Changing cream pearls into bluish-grey by #gamma# ray irradiation is a technique in coloring of pearls. Irradiated pearls are similar in color to cultured blue pearls. The pearl layers hardly change their color but the nuclei change into dark brown by irradiation. Visible light (500 - 700 nm) penetrating the pearl layer is absorbed by dark brown nucleus. The intensity of reflecting light between 400 and 500 nm at pearl surface, therefore, becomes stronger than that between 500 and 700 nm; therefore color of irradiated pearls look bluish-grey. The density of bluish-grey color increases with increasing absorbed doses, but their luster at surface diminishes owing to the deterioration of the pearl layer by prolonged irradiation; high doses irradiation should be avoided. Irradiated pearls show no substantial fading of their color in a year and the rate of the fading is found to be lower than that for ...
Energy Technology Data Exchange (ETDEWEB)
To date, no single passive detector has been found that measures dose equivalent from ionizing radiation exposure in low-Earth orbit. We have developed the I.S.S. Passive Dosimetry System (P.D.S.), utilizing a combination of TLD in the form of the self-contained Pille TLD system and stacks of CR-39 plastic nuclear track detector (P.N.T.D.) oriented in three mutually orthogonal directions, to measure total dose and dose equivalent aboard the International Space Station (I.S.S.). The Pille TLD system, consisting on an on board reader and a large number of Ca{sub 2}SO{sub 4}:Dy TLD cells, is used to measure absorbed dose. The Pille TLD cells are read out and annealed by the I.S.S. crew on orbit, such that dose information for any time period or condition, e.g. for E.V.A. or following a solar particle event, is immediately available. Near-tissue equivalent CR-39 ...
2006-07-01
CT-Expo - a novel program for dose evaluation in CT
International Nuclear Information System (INIS)
CT-Expo is a novel MS Excel application for assessing the radiation doses delivered to patients undergoing CT examinations, based on computational methods that were used to analyze the data collected in the German survey on CT practice in 1999. The program enables the calculation of all dose quantities of practical value, such as axial dose free-in-air, weighted CTDI, dose-length product, effective dose and uterine dose. In contrast to existing programs for CT dose assessment, CT-Expo offers a number of unique features, such as gender-specific dose calculation for all age groups (adults, children, newborns), applicability to all existing scanner models including correction of scanner-specific influences, and the possibility of comparison with the results from the German CT survey ...
2002-12-01
Energy Technology Data Exchange (ETDEWEB)
A thermoluminescence (TL) sheet and its spatial readout system for in vivo measurement of spatial dose distribution around sources has been newly developed for intracavitary high dose-rate radiation therapy. The TL sheet (40 cm x 50 cm x 200 {mu}m), which is composed of teflon mixed with BaSO{sub 4} (Eu doped) powder, has a linear response with a very wide dynamic range from at least 0.002 cGy to 5000 cGy for {sup 60}Co sources. Phantom test of the TL sheet readout system demonstrated that absorbed dose with TL sheet and that with ionization chamber as standard dosimeter agreed well. For clinical application, TL sheet was attached on an applicator of intracavitary radiation therapy for rectal cancer. After irradiation with high dose-rate {sup 60}Co sources, the in vivo dose distribution on the surface of the rectum was determined. The TL sheet was suggested to ...
1991-06-01
Effective dose equivalent concept in radiopharmaceutical dosimetry
Energy Technology Data Exchange (ETDEWEB)
The Effective Dose Equivalent Concept defined by the International Commission on Radiological Protection in 1977 considers the risk from irradiation including both hereditary and somatic effects. This paper will deal with the definition of a concept for somatic effects only, the somatically significant dose equivalent. This is defined as the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by various individuals. The somatically effective dose equivalent for a particular radiopharmaceutical is the weighted sum of the average dose equivalent to various organs. The dose equivalent to various organs can be derived from an extended MIRD formalism also considering the rest of body excluding the source ...
1981-06-01
Effective dose equivalent concept in radiopharmaceutical dosimetry
International Nuclear Information System (INIS)
The Effective Dose Equivalent Concept defined by the International Commission on Radiological Protection in 1977 considers the risk from irradiation including both hereditary and somatic effects. This paper will deal with the definition of a concept for somatic effects only, the somatically significant dose equivalent. This is defined as the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by various individuals. The somatically effective dose equivalent for a particular radiopharmaceutical is the weighted sum of the average dose equivalent to various organs. The dose equivalent to various organs can be derived from an extended MIRD formalism also considering the rest of body excluding the source ...
Paediatric radiography - the avoidance of late radiation damage to the growing hip
Energy Technology Data Exchange (ETDEWEB)
Epiphyseal plates of growing bones are sensitive to ionizing radiation and this poses problems for the paediatric radiotherapist. In this case report we describe a child in whom electron beam therapy to the groin delivered only low dose radiation to the proximal hip epiphyses - 130 cGy fractionated over 5 weeks - but who suffered late maldevelopment. We explore the success of various radiotherapy techniques in minimizing the dose to the hip epiphyses in four other children. The appropriate positioning of the limb, the choice of treatment modality and, where possible, individual shielding blocks are considered and their effect on the dose to the hip estimated. Absorbed doses of radiation delivered to the midpoint of the proximal femoral epiphyses have been retrospectively determined. (author).
1993-04-01
Organ doses and integral doses in X-ray diagnosis of the chest and of the head
International Nuclear Information System (INIS)
Organ and tissue doses and integral doses in patients due to diagnostic x-ray examinations of the chest and of the head will be presented. These data have been obtained by measuring the dose distributions in man phantoms by LiF-dosimetry. The data will be compared with data obtained by Monte-Carlo calculations. To obtain average organ doses for a special type of examination for the population or for a specified subpopulation in the variation of the exposure, data due to the different techniques used by the different radiologists has to be known. Such data will be presented. The results of the investigation will be discussed in connection with the concept of the 'somatic significant.
1977-04-01
Analysis of photon beam exit dose using photon point kernels
International Nuclear Information System (INIS)
The Monte Carlo method is used to analyse the dose fall-off at the exit surface of a megavoltage photon beam. The convolution/superposition method of dose calculation using Monte-Carlo-generated homogeneous photon kernels is shown to be in error for exit dose calculation. Instead, photon kernels that incorporate modelling of the exit surface were generated, also using Monte Carlo, to analyse the problem, and the calculated dose fall-off using these kernels agrees well with measured data. In addition, the physics underlying the characteristics of the dose fall-off is analysed based on complete Monte Carlo modelling. Practical improvements to the convolution/superposition method are suggested. (Author).
The use of calcium silicate bricks for retrospective dosimetry
International Nuclear Information System (INIS)
The suitability of calcium silicate bricks (CSBs) for the retrospective measurement of gamma dose using luminescence techniques has been investigated. Bricks of this type are distinguished from fired clay bricks by containing negligible clay and requiring comparatively low temperature treatment during manufacture. They have been used widely in the construction f buildings in the Former Soviet Union since the 1970s but hitherto have not been used for retrospective dosimetry measurements. A procedure based on the se of the 210 deg. C thermoluminescence (TL) peak of quartz was tested with granular quartz extracted from three types of CSB, one of which had been taken from a settlement downwind of Chernobyl. The degree to which the residual geological TL signal within the temperature range of the 210 deg. C L peak had been reduced during manufacture varied with brick type; the levels of residual TL corresponded, in the samples tested, to absorbed ...
2004-02-01
Radon concentrations and absorbed dose measurements in a Pleistocenic cave
International Nuclear Information System (INIS)
Radon concentration measurements were carried out using solid-state nuclear track-etch detectors (SSNTDs) type CA 80-15 cellulose nitrate films, in a Pleistocenic cave at Petralona, in Halkidiki, Northern Greece, at 55 km from the city of Thessaloniki. Radon levels as high as 88 kBqxm"-"3 (2.38 nCi x l"-"1) have been recorded inside the cave equivalent to 11.90 WL in terms of occupational exposure to radon and its decay products. Absorbed dose rates were performed using TL dosimeters, type TLD-200 (CaF_2-Dy) in a continuous monitoring program (integrated measurements). Dose rate levels as high as 110 nGy x h"-"1 were recorded inside the cave. In interpreting the high levels of radiation doses, radioactivity measurements regarding the naturally occurring "2"3"8U, "2"3"2Th and "4"0K radionuclides were carried out in various speleothems found at different sites in the cave. (author)
2003-10-01
Lung dose calculations at kilovoltage x-ray energies using a model-based treatment planning system
International Nuclear Information System (INIS)
The determination of the dose to organs from diagnostic x rays has become important because of reports of radiation injury to patients from fluoroscopically guided interventional procedures. We have modified a convolution/superposition-based treatment planning system to compute the dose distribution for kilovoltage beams. We computed lung doses using this system and compared them to those calculated using the CDI3 organ dose calculation program. We also computed average lung doses from a simulated radiofrequency ablation procedure and compared our results to published doses for a similar procedure. Doses calculated using this system were an average of 20% lower for AP beams and 7% higher for PA beams than those obtained using CDI3. The ratio of the average ...
2001-02-01
Dose verification using a pelvic phantom in high dose rate (HDR) brachytherapy
Energy Technology Data Exchange (ETDEWEB)
High dose rate (HDR) brachytherapy for treating a cervix carcinoma has become popular, because it eliminates many of the problems associated with conventional brachytherapy. In order to improve the clinical effectiveness with HDR brachytherapy, a dose calculation algorithm, optimization procedures, and image registrations need to be verified by comparing the dose distributions from a planning computer and those from a humanoid phantom. In this study, the humanoid phantom was fabricated in order to verify the absolute doses and the relative dose distributions. The measured doses from the humanoid phantom were then compared with the treatment planning system for the dose verification. The humanoid phantom needs to be designed such that the dose distributions can be quantitatively evaluated ...
2003-07-01
Energy Technology Data Exchange (ETDEWEB)
Methylmethacrylate polymerisation in the presence of 4 wt% butadiene-acrylonitrile rubber was carried out at fixed dose-rate and temperature. The effect of irradiation was investigated with respect to the mechanical and dynamic-mechanical properties in the solid state. A general increase of the 'compatibilisation' on irradiation is obtained. In fact both rubber and polymethylmethacrylate glass transition temperatures, determined through dynamic-mechanical analysis, reveal the presence of strong interactions between the components. Furthermore an improvement of the mechanical tensile properties of the blends is observed when irradiation is continued after polymerisation, at least until a certain absorbed dose.
2001-12-01
Survey of radiation doses to patients from the diagnostic use of X-rays
International Nuclear Information System (INIS)
The National Radiological Protection Board is to carry out a survey of doses received by patients from the diagnostic use of X-rays, beginning in June 1977, and carried out at over 100 National Health Service hospitals. Details are given of the reasons for carrying out the survey and the survey objectives. The survey working methods are discussed, together with methods of calculation of the genetically significant dose. The radiation doses will be measured by a thermoluminescent dosimeter developed specially for the survey. (U.K.).
1977-06-01
Energy Technology Data Exchange (ETDEWEB)
The risks from radiation exposure during radiological diagnosis has usually been estimated in relation to genetic changes. Relevant information has been expressed as the genetically significant dose. In this paper we attempt to produce an analogous measure for evaluating the somatic risk in the form of a somatically significant dose index for radiological and CT examinations. It is shown that, for both types of examination, the two risk factors may be entirely different.
1980-10-01
International Nuclear Information System (INIS)
The risks from radiation exposure during radiological diagnosis has usually been estimated in relation to genetic changes. Relevant information has been expressed as the genetically significant dose. In this paper we attempt to produce an analogous measure for evaluating the somatic risk in the form of a somatically significant dose index for radiological and CT examinations. It is shown that, for both types of examination, the two risk factors may be entirely different. (orig.).
1980-01-01
Optimizing an analytical dose calculation algorithm for fast 2D calculations
International Nuclear Information System (INIS)
Previously, an analytical dose calculation algorithm for MLC-based radiotherapy was developed and commissioned, which includes a detailed model of various MLC effects as a unique feature [1]. The algorithm was originally developed as an independent verification of the treatment planning system's dose calculation and it explicitly modeled spatial and depth dependent MLC effects such as interleaf transmission, the tongue-and-groove effect, rounded leaf ends, MLC scatter, beam hardening, and gradual MLC transmission fall-off with increasing off-axis distance. Originally the algorithm was implemented in Mathematica trademark (Wolfram). To speed up the calculation time and to be able to calculate high resolution 2D dose distributions within a reasonable time frame (<2 s) the algorithm needs to be optimized and to be embedded in a user friendly ...
AIDE: internal dosimetry software.
AIDE (Activity and Internal Dose Estimates) is a software for calculating activities in compartments and committed doses due to occupational exposures, and for performing intake and dose estimates using bioassay data. It has been continuously developed and tested for more than 20 years. Its calculation core has been applied in several situations, like performing all dose estimates due to (137)Cs intakes, which occurred during the Goiania accident in 1987; performing quality assurance of the ICRP Task Group on Dose Calculations regarding calculations of activities in compartments and generation of dose coefficients for adults due to intakes by inhalation, ingestion and injection of several radionuclides; and producing the tables of activities in compartments and ...
2008-03-12
International Nuclear Information System (INIS)
Convolution/superposition (C/S) is regarded as the standard dose calculation method in most modern radiotherapy treatment planning systems. Different implementations of C/S could result in significantly different dose distributions. This paper addresses two major implementation issues associated with collapsed cone C/S: one is how to utilize the tabulated kernels instead of analytical parametrizations and the other is how to deal with voxel size effects. Three methods that utilize the tabulated kernels are presented in this paper. These methods differ in the effective kernels used: the differential kernel (DK), the cumulative kernel (CK) or the cumulative-cumulative kernel (CCK). They result in slightly different computation times but significantly different voxel size effects. Both simulated and real multi-resolution dose calculations are presented. For simulation tests, we use ...
2005-02-21
International Nuclear Information System (INIS)
Accurate dose calculation in radiation treatment planning is most important for successful treatment. Since human body is composed of various materials and not an ideal shape, it is not easy to calculate the accurate effective dose in the patients. Many methods have been proposed to solve inhomogeneity and surface contour problems. Monte Carlo simulations are regarded as the most accurate method, but it is not appropriate for routine planning because it takes so much time. Pencil beam kernel based convolution/superposition methods were also proposed to correct those effects. Nowadays, many commercial treatment planning systems have adopted this algorithm as a dose calculation engine. The purpose of this study is to verify the accuracy of the dose calculated from pencil beam kernel based treatment planning system ...
2002-10-20
Stochastic risk estimate for barium radiological examinations in Malaga (Spain)
International Nuclear Information System (INIS)
The aim of this research work has been the estimation of the stochastic risk for five barium examinations. The sample was the population attending the Radiological Service of the 'Nuestra Senora de la Victoria' University Hospital, who had been treated with some barium examinations, set in five different groups: oesophagus tract, oesophagus-gastric-duodenal tract, intestinal tract, enteroclysis and double enema. To estimate the stochastic risk, it is necessary to know the organ dose. This can be calculated from the dose-area product which allows us to determine the effective dose using software. The dose-area product is the most suitable quantity to measure in these types of examination. We have evaluated the contribution that each procedure provides to the genetically significant dose, somatically significant dose, collective effective ...
2000-01-01
International Nuclear Information System (INIS)
Objective: To investigate the relationship between exposure dose and image quality for a direct digital radiography system and to determine the optimum exposure parameters for pelvic examination. Methods: A contrast-detail phantom CDRAD2.0 was exposed to different doses and the IQF of phantom images were calculated. The optimum exposure parameters were determined by ANOVA and SNK analysis. The image of an anthropomorphic phantom taken with optimized exposure parameters was verified using CEC image criteria. Results: The IQF of the images of CDRAD2.0 phantom was significantly different for different doses, as the exposure dose was greater than 0.61 mGy. The IQFs have no difference for different dose groups. The image quality between this optimized exposure dose and conventional exposure dose not was significantly ...
2005-10-01
International Nuclear Information System (INIS)
Despite the widely recognized usefulness of the AAPM TG-43 brachytherapy dose calculation formalism, a straightforward application of this approach to describe the dose distribution about intravascular line sources as proposed by TG-60 may be difficult or even impossible, especially when these line sources emit low-energy photons or beta particles. The causes of these limitations are investigated and illustrated by means of some numerical examples. In order to solve the observed limitations an adapted formalism is proposed, intended specifically for the description of the dose rate distribution about line sources but conceptually similar to the TG-43/TG-60 formalism. Several examples are presented to illustrate the usefulness of the proposed line source dose calculation formalism.
2001-04-01
Photon beam modelling with Pinnacle3 Treatment Planning System for a Rokus M Co-60 Machine
International Nuclear Information System (INIS)
The basic relationships of the convolution/superposition dose calculation technique are reviewed, and a modelling technique that can be used for obtaining a satisfactory beam model for a commercially available convolution/superposition-based treatment planning system is described. A fluence energy spectrum for a Co-60 treatment machine obtained from a Monte Carlo simulation was used for modelling the fluence spectrum for a Rokus M machine. In order to achieve this model we measured the depth dose distribution and the dose profiles with a Wellhofer dosimetry system. The primary fluence was iteratively modelled by comparing the computed depth dose curves and beam profiles with the depth dose curves and crossbeam profiles measured in a water phantom. The objective of beam modelling is to build a model of the primary fluence that the patient is exposed to, which can ...
Effect of Nordic diets on ECOSYS model predictions of ingestion doses
British Library Electronic Table of Contents (United Kingdom)
The ECOSYS model is used to estimate ingestion dose in the ARGOS and RODOS decision support systems for nuclear emergency management. It is recommended that nation-specific values for several parameters are used in the model. However, this is generally overlooked when the systems are used in practice. We have estimated first year ingestion doses in two scenarios with wet and dry deposition of 137Cs, using the ECOSYS model. We calculated doses for each country using national dietary data while keeping all other parameters at their default values. These dose calculations were then used to estimate the variation in ingestion doses resulting from the variation in the diets only. The dietary data demonstrated that the average consumption of milk, meat and vegetables varied by a factor of 2-4 am...
2010-01-01
Comparing dose calculation algorithms for an orthovoltage beam in a bone phantom
International Nuclear Information System (INIS)
The aim of this work was to compare dose calculation algorithm results at orthovoltage energies for a phantom composed of a bone slab in water. The calculation methods investigated were: no correction, ETAR, Batho, convolution/superposition and Monte Carlo. All algorithms calculated depth dose curves in a water phantom within 4% of experiment. However in the bone phantom, differences of over 40% between the No Correction / ETAR / Batho / Convolution and Monte Carlo results in the 1 cm thick bone slab were observed. These differences are predominantly because the algorithms do not account for the differing atomic number of the bone compared to water The increased dose to bone and the tissue adjacent to the bone interface should be considered when treating with orthovoltage photons. Copyright (1998) Australasian Physical and Engineering Sciences in Medicine
1998-09-01
International Nuclear Information System (INIS)
Natural radioactive materials under certain conditions can reach hazardous radiological levels. The natural radionuclide ("2"3"8U, "2"3"2Th, "4"0K) contents of rock samples at various locations in the North Tushki area were investigated using gamma-spectrometric analysis. Estimates of the measured radionuclide content have been made for the absorbed dose rate of gamma radiation. The equivalent radium (R_e_q) and the external hazard index (H_e_x) which resulted from the natural radionuclides in soil are also calculated and tabulated. The studied samples have been collected from various rock exposures in the North Tushki area. The distribution of major oxides, U and Th were studied. It is found that the enrichment and depletion of the major oxides are mainly due to the effect of hydrothermal alteration, which caused mobility of some major oxides, which increases some elements and decreases others. It is important to mention ...
2002-09-01
British Library Electronic Table of Contents (United Kingdom)
We performed experimental studies on the convolution/superposition method reported in the former companion paper (Iwasaki in Radiol Phys Technol 4, 2011) using 10-MV X-ray beams from open-jaw-collimated fields. The method uses primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. We made a comparison of calculations and measurements in water phantoms and thorax-like phantoms with respect to percentage depth dose curves, tissue???phantom ratio curves, and dose profiles. We made the dose calculation by taking into account the beam-hardening effect with depth and the off-axis radiation-softening effect. We found that the method could be used, in general, for performing accurate dose calculations.
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
The purpose of this report is to summarize the assumptions, dose factors, consumption rates, and methodology used to evaluate potential radiation doses to persons who may eat contaminated wildlife or contaminated plants collected from the Hanford Site. This report includes a description of the number and variety of wildlife and edible plants on the Hanford Site, methods for estimation of the quantities of these items consumed and conversion of intake of radionuclides to radiation doses, and example calculations of radiation doses from consumption of plants and wildlife. Edible plants on the publicly accessible margins of the shoreline of the Hanford Site and Wildlife that move offsite are potential sources of contaminated food for the general public. Calculations of potential radiation doses from consumption of agricultural plants and farm ...
1990-10-01
Energy Technology Data Exchange (ETDEWEB)
Collective dose equivalent and population dose from occupational exposures in Japan, 1988 were estimated on the basis of a nationwide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 0.21 million workers except for the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the official report of the Japan Nuclear Safety Commission. The total number of workers including nuclear power stations was estimated to be about 0.26 million. Radiation works were subdivided as follows: medical works including dental; non-atomic energy industry; research and education; atomic energy industry and nuclear power station. For the determination of effective dose equivalent and population dose, organ or tissue doses were measured with a phantom experiment. ...
1993-05-01
International Nuclear Information System (INIS)
Collective dose equivalent and population dose from occupational exposures in Japan, 1988 were estimated on the basis of a nationwide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 0.21 million workers except for the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the official report of the Japan Nuclear Safety Commission. The total number of workers including nuclear power stations was estimated to be about 0.26 million. Radiation works were subdivided as follows: medical works including dental; non-atomic energy industry; research and education; atomic energy industry and nuclear power station. For the determination of effective dose equivalent and population dose, organ or tissue doses were measured with a phantom experiment. ...
1993-01-01
Mathematical child phantom for the calculation of dose to the organs at risk
Energy Technology Data Exchange (ETDEWEB)
In order to calculate the doses received by the organs of 530 children treated by radiation for cancer between 1945 and 1969 at the G. Roussy Institute, we have developed a computer program for organ location calculation. To calculate the location of each child's organs of interest at the time of the treatment, only two parameters are necessary; sex and height or sex and age when the height at the time of the treatment is unknown. The algorithm is based on the metric studies of growth known as auxology. Each organ is located by one point representing its center. The model has been checked on 100 healthy children.
1988-05-01
A doubly Q-switched laser with both an acousto-optic (AO) modulator and a GaAs saturable absorber can obtain a more symmetric and shorter pulse with high pulse peak power, which has been experimentally proved. The key parameters of an optimally coupled doubly Q-switched laser with both an AO modulator and a GaAs saturable absorber are determined, and a group of general curves are generated for what we believe is the first time, when the single-photon absorption (SPA) and two-photon absorption (TPA) processes of GaAs are combined, and the Gaussian spatial distributions of the intracavity photon density and the initial population-inversion density as well as the influence of the AO Q-switch are considered. These key parameters include the optimal normalized coupling parameter, the optimal normalized GaAs saturable absorber parameters, and the normalized parameters of the AO Q-switch, which can maximize the output energy. ...
2007-08-20
Retrospective Monte Carlo dose calculations with limited beam weight information
International Nuclear Information System (INIS)
An important unresolved issue in outcomes analysis for lung complications is the effect of poor or completely lacking heterogeneity corrections in previously archived treatment plans. To estimate this effect, we developed a novel method based on Monte Carlo (MC) dose calculations which can be applied retrospectively to RTOG/AAPM-style archived treatment plans (ATP). We applied this method to 218 archived nonsmall cell lung cancer lung treatment plans that were originally calculated either without heterogeneity corrections or with primitive corrections. To retrospectively specify beam weights and wedges, beams were broken into Monte Carlo-generated beamlets, simulated using the VMC++ code, and mathematical optimization was used to match the archived water-based dose distributions. The derived beam weights (and any wedge effects) were then applied to Monte Carlo beamlets regenerated based on the patient ...
2007-01-01
Population exposure to external natural radiation background in the United States
Energy Technology Data Exchange (ETDEWEB)
This report revises estimates of population exposure to external natural background made by D. T. Oakley in 1972. The revisions include more recent estimates of dose equivalents from cosmic rays, use of 1970 U.S. census data, and corrections for building shielding and for self-shielding in the body. The dose equivalents calculated are those from cosmic rays and terrestrial radiation, and do not include doses from natural radioactive materials in the body.
1981-04-01
Scattered radiation effect on the defect image in high-energy bremsstrahlung introscopy
International Nuclear Information System (INIS)
Results of the evaluation of the scattered radiation effect on the image of defects in examined products are given. The formula is suggested which characterizes the image of defects on a scintillation screen as well as accumulation factors are calculated by the Monte-Carlo method. Values of fluctuations of absorbed energy in the screen used for the evaluation of sensitivity are experimentally obtained. The effect of high-energy bremsstrahlung on the defect detection is analyzed.
Energy Technology Data Exchange (ETDEWEB)
Pyrheliometric methods are described (particularly methods for measuring the solar constant), and theoretical and experimental studies in this field are surveyed and systematized. Particular attention is given to the analysis of instruments intended for pyrheliometers used as standards, reference instruments, and solar-constant meters is examined, and consideration is given to methods for determining the thermal-radiation properties of absorbing coatings and methods for calculating the absorption coefficients of cavity receivers.
1981-01-01
Analysis of a manipulator in relation to collision between a link and an object
British Library Electronic Table of Contents (United Kingdom)
In this article, equations of motion of a manipulator are derived after consideration of the characteristics of the driving source. By considering a collision between a link and an object, and considering the active motion to absorb the kinetic energy of the object, the trajectories for saving energy are calculated by the iterative dynamic programming (IDP) method. The dynamic characteristics of manipulator control based on the trajectory for saving energy are also analyzed theoretically and investigated experimentally.
2011-01-01
International Nuclear Information System (INIS)
An numerical method was developed for measuring radiant temperature using a set of absorption-foils coupled to soft x ray streak camera, SXRSC, in laser plasma experiments. An numerical code, SCC, was given. An x-ray intensity ratio vs temperature was calculated for Parylene, C_3H_6, Mylar and Aluminium. A suitable range of the measuring temperature was discussed to some absorber.
1990-01-01
Radiation protection of the personnel who will perform interventions in the LHC Beam Cleaning Insertions is mandatory and includes the design of equipment and the establishment of work procedures. Residual dose rates due to activated equipment are expected to reach significant values such that any maintenance has to be planned and optimized in advance. Three-dimensional maps of dose equivalent rates at different cooling times after operation of the LHC have been calculated with FLUKA. The simulations are based on an explicit calculation of induced radioactivity and of the transport of the radiation from the radioactive decay. The paper summarizes the results for the Beam Cleaning Insertions and discusses the estimation of individual and collective doses received by personnel during critical interventions, such as the exchange of a collimator or the installation of Phase 2. The given ...
2005-01-01
Tissue Heterogeneity in IMRT Dose Calculation for Lung Cancer
International Nuclear Information System (INIS)
The aim of this study was to evaluate the differences in accuracy of dose calculation between 3 commonly used algorithms, the Pencil Beam algorithm (PB), the Anisotropic Analytical Algorithm (AAA), and the Collapsed Cone Convolution Superposition (CCCS) for intensity-modulated radiation therapy (IMRT). The 2D dose distributions obtained with the 3 algorithms were compared on each CT slice pixel by pixel, using the MATLAB code (The MathWorks, Natick, MA) and the agreement was assessed with the ? function. The effect of the differences on dose-volume histograms (DVHs), tumor control, and normal tissue complication probability (TCP and NTCP) were also evaluated, and its significance was quantified by using a nonparametric test. In general PB generates regions of over-dosage both in the lung and in the tumor area. These differences are not always in DVH of the lung, although the Wilcoxon test indicated ...
2011-01-01
Calculating electron dose using a convolution/superposition method. 120
International Nuclear Information System (INIS)
The calculation of electronn beam dose using an algorithms similar to convolution/superposition methods for photon beams [1,2,3,4] is explored. The distribution of dose deposited by a number of monoenergetic, point-monodirectional electron pencil beams is first determined using the Monte Carlo method [5,6]. These elementary distributions are combined to model distributions that would result from the spectrum of incident energies and angles [6,7] present in a clinical beam. These modified distributions are then stored for use as kernels in the dose calculation. In the case of a homogeneous phantom, the relative fluence distribution is convolved with the stored kernels to obtain thhe dose distributions in 3 dimensions. Since the kernels cannot be assumed to be spatially invariant in a heterogeneous water-like phantom, the dose deposited on ...
AAPM TG-43 formalism for brachytherapy dose calculation of a 137Cs tube source
International Nuclear Information System (INIS)
We present a development of the use of the AAPM TG-43 dose formalism applied to "1"3"7Cs gynecological implant sources. The geometry factor, radial dose function, and anisotropy function of a "1"3"7Cs source modeled after the Nuclear Associates 67-809 series stainless steel jacketed tube source were derived following the AAPM TG-43 formalism. The dose rate distribution through the center of the source using the AAPM TG-43 dose formalism is calculated and compared with the calculations obtained using the Sievert summation and Monte Carlo simulation. The three methods resulted in an agreement within less than 5%, or an isodose rate line agreement within 2 mm. We demonstrate that the AAPM TG-43 formalism can be applied to "1"3"7Cs linear sources and is capable of serving as a "1"3"7Cs dose calculation algorithm that can be ...
2004-04-01
EPR investigation of some traditional oriental irradiated spices
International Nuclear Information System (INIS)
The 9.50 GHz electron paramagnetic resonance (EPR) spectra of unirradiated and "6"0Co #gamma#-ray irradiated cardamom (Elettaria cardamomum L. Maton, Zingiberaceae), ginger ((Zingiber officinale Rosc., Zingiberaceae), and saffron (Crocus sativus L., Iridaceae) have been investigated at room temperature. All unirradiated spices presented a weak resonance line with g-factors around free-electron ones. After #gamma#-ray irradiation at an absorbed dose of up to 11.3 kGy, the presence of EPR spectra whose amplitude increase monotonously with the absorbed dose has been noticed with all spices. A 100 "oC isothermal annealing of 11.3 kGy irradiated samples has shown a differential reduction of amplitude of various components that compose initial spectra, but even after 3.6 h of thermal treatment, the remaining amplitude represents no less then 30% of the initial ones. The same peculiarities have been noticed ...
2007-06-01
EPR investigation of some irradiated traditional oriental spices
International Nuclear Information System (INIS)
The X-band EPR spectra of unirradiated and "6"0 Co gamma ray irradiated cardamom (Elettaria cardamomum L. Maton, Zingiberaceae), ginger ((Zingiber officinale Rosc., Zingiberaceae), saffron (Crocus sativus L., Iridaceae), and curry have been investigated at room temperature. All unirradiated spices presented a weak resonance line with g-factors around free-electron ones, most probably due to the presence of semiquinones, previously reported to have paramagnetic properties. After gamma ray irradiation at absorbed dose up to 11.3 kGy we have noticed in all spices the presence of complex EPR spectra consisting of a superposition of at last two different paramagnetic species whose amplitude increase monotonously with the absorbed dose. A 100 deg. C isothermal annealing of 11.3 kGy irradiated samples has shown a differential reduction of amplitude of various components that form the initial spectra, but even ...
2005-09-13
Information detective quantum efficiency of X-ray film-intensifier foil systems
Energy Technology Data Exchange (ETDEWEB)
The capability of screen-film combinations of detection and representation of information is described by the detective quantum efficiency (DQE). The DQE may be calculated from the sensitivity, the gradient of the characteristic curve, the modulation transfer function and the Wiener spectrum. These parameters have been determined for fourteen screen-film combinations and the DQE's have been calculated. It is shown that the low frequency region the DQE does not depend on spatial frequency. This constant level of DQE is mostly dependent on the absorbance of the screens. Consequences from this fact, as well for the manufacturer as for the user of the screens, are discussed.
1988-04-01
Information detective quantum efficiency of X-ray film-intensifier foil systems
International Nuclear Information System (INIS)
The capability of screen-film combinations of detection and representation of information is described by the detective quantum efficiency (DQE). The DQE may be calculated from the sensitivity, the gradient of the characteristic curve, the modulation transfer function and the Wiener spectrum. These parameters have been determined for fourteen screen-film combinations and the DQE's have been calculated. It is shown that the low frequency region the DQE does not depend on spatial frequency. This constant level of DQE is mostly dependent on the absorbance of the screens. Consequences from this fact, as well for the manufacturer as for the user of the screens, are discussed. (orig.).
International Nuclear Information System (INIS)
Background and purpose: A series of phase I/II clinical trials are being initiated in several UK centres to explore the use of dose-escalated schedules for the treatment of non-small cell lung cancer (NSCLC). Among them the IDEAL-CRT trial (ISRCTN12155469) will investigate the introduction of individualised 'isotoxic' treatment schedules based on the relative mean lung normalised total dose (rNTDmean), an estimator related to lung toxicity. Since treatment planning will be performed using different treatment planning systems (TPSs), for the quality assurance of the trial we have carried out work to quantify the influence of dose calculation algorithms based on the determination of rNTDmean and on the choice of individualised prescription doses. Material and methods: Twenty-five patient plans with stage I, II and III NSCLC were calculated, with the same ...
2010-12-01
Energy Technology Data Exchange (ETDEWEB)
Survival curves were constructed from dose-incidence curves for apoptosis in the crypts of mouse small intestine, using the number of apoptotic cells after high doses (N{sub M}) as maximum cell population size. The mean lethal doses (D{sub 0}) for the dose range 0-0.5 Gy were calculated for each time of day. A circadian rhythm in both D{sub 0} and N{sub M} values was detected, indicating that both the number and sensitivity of radiation-induced apoptosis were changing throughout the day. (author).
1990-07-01
Somatic radiation risk in X-ray diagnostics
Energy Technology Data Exchange (ETDEWEB)
The authors give a survey of the somatic radiation risk in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk.
1983-12-01
Somatic radiation risk in X-ray diagnostics
International Nuclear Information System (INIS)
The authors give a survey of the somatic radiation ris in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk. (orig.).
1983-01-01
Review of electron beam therapy physics
Energy Technology Data Exchange (ETDEWEB)
For over 50 years, electron beams have been an important modality for providing an accurate dose of radiation to superficial cancers and disease and for limiting the dose to underlying normal tissues and structures. This review looks at many of the important contributions of physics and dosimetry to the development and utilization of electron beam therapy, including electron treatment machines, dose specification and calibration, dose measurement, electron transport calculations, treatment and treatment-planning tools, and clinical utilization, including special procedures. Also, future changes in the practice of electron therapy resulting from challenges to its utilization and from potential future technology are discussed. (review)
2006-07-07
Patient doses in the Netherlands. [X-ray diagnosis and radiotherapy
Energy Technology Data Exchange (ETDEWEB)
Contributions to the population dose due to medical applications of ionising radiation are presented. It appears that contributions due to radiotherapy and X ray diagnosis are of comparable magnitude. To account for the age dependency of the radiation risks, contributions in terms of somatically significant dose equivalent are calculated as 0.3 mSv per caput per annum for X ray diagnosis and as 0.2 mSv per caput per annum for radiotherapy, the latter referring to only doses to organs outside the target volume. (author).
1991-01-01
A marine compartment model for collective dose assessment of liquid radioactive effluents
International Nuclear Information System (INIS)
A compartment model is described which is currently used by the Ministry of Agriculture, Fisheries and Food to calculate collective radiation exposure due to liquid radioactive wastes discharged to sea from UK nuclear sites. Collective dose is a useful indicator of the radiological impact of a disposal practice and is one of the quantities needed to show compliance with the ICRP system of dose limitation. The model has been used for the purposes of the Sizewell Inquiry to predict the collective radiation exposure from reactor operation at Sizewell and, on the basis of current Sellafield experience, correlations between dose and discharge for disposals of fuel reprocessing wastes. (author).
1982-01-01
Thermoluminescent (Tl) dosimetry of slow-neutron fields at radiotherapy dose level
Energy Technology Data Exchange (ETDEWEB)
The dosimetry for radiotherapy involving neutrons is very complicated, owing to the complexity of secondary radiation components, whose contributions to the total absorbed dose have to be discriminated, owing to the different radiobiological effects. In order to separate thermal neutrons and photons, LiF dosimeters are mostly utilized. containing different percentage of Li, like as TLD-700, TLD-100 and TLD-600, but many problems arise. In the response of TLD-700 exposed to neutron-gamma mixed fields with high neutron flux, the contribution of thermal neutrons to the Tl emission is high. Moreover. TLD-100 and TLD-600 may undergo radiation damage, and great care has to be taken in order to obtain reliable results. Other TLDs showing lower sensitivity to neutrons are proposed and experimented for such high-flux neutron fields. The faced problems and various proposed solutions are here described. (Author)
2003-07-01
Chemical Analysis of Solid-State Irradiated Human Insulin
British Library Electronic Table of Contents (United Kingdom)
Purpose To study the chemical modifications induced upon irradiation of solid human insulin at radiosterilization doses and investigate the influence of the absorbed dose on radiolysis. Materials and Methods Volatile radiolytic products were monitored by gas chromatography coupled with mass spectrometry (GC-MS) and non-volatile products by two different high performance liquid chromatography (HPLC) methods: the formation of higher molecular weight proteins was assessed by size exclusion liquid chromatography whereas assays for related compounds and chemical potency tests were carried out using reverse-phase HPLC-UV. Conformational changes were investigated by measurements of circular dichroism. Results After gamma irradiation at 10?kGy, the recovery of insulin was 96.8%; higher molecular w...
2006-01-01
The calculation of derived release limit on Wolsung NPPs based on reduced public dose limit
Energy Technology Data Exchange (ETDEWEB)
According to enactment of reduced dose limit based on ICRP-60, the calculation of Derived Release Limits(DRL) on Wolsung NPPs was carried out. There are two methods of determination on DRL; that is MPC(Maximum Permissible Concentration) method and system analysis method. In order to use the system analysis method, lots of environmental data are necessary and complicated exposure pathway are considered. So we intend to apply MPC method that is sort of simple. In addition the calculated results were compared with derived release limit on Canadian nuclear power plant.
2000-10-01
International Nuclear Information System (INIS)
The global effect of activation cross-section uncertainties on calculated radiological quantities is investigated for the first time using a methodology based on Monte Carlo random sampling. The method is applied to the calculation of the uncertainty in the contact dose rate from the gunite shielding of the National Ignition Facility chamber after 30 yr of pulsed irradiation. Some critical cross section contributing significantly to the overall uncertainty are identified. By a reasonable reduction of the uncertainty in those cross sections, the accuracy in the calculated total contact dose rate is greatly improved.
2003-05-01
Whole-body counting in the Marshall Islands
Energy Technology Data Exchange (ETDEWEB)
In 1978 the Marshall Islands Radiological Safety Program was organized to perform radiation measurements and assess radiation doses for the people of the Bikini, Enewetak, Rongelap and Utirik Atolls. One of the major field components of this program is whole- body counting (WBC). WBC is used to monitor the quantity of gamma- emitting radionuclides present in individuals. A primary objective of the program was to establish {sup 137}Cesium body contents among the Enewetak, Rongelap and Utirik populations. {sup 137}Cs was the only gamma-emitting fission radionuclide detected in the 1,967 persons monitored. {sup 137}Cs body burdens tended to increase with age for both sexes, and were higher in males. The average {sup 137}Cs dose Annual Effective Dose for the three populations was as follows: For Enewetak, the dose was 22{+-}4 {mu}Sv. For Utirik, the dose was 33{+-} 3 {mu}Sv. Since 1985 ...
1991-01-01
The somatically significant dose, SSD, and analog of the GSD, the genetically significant dose
International Nuclear Information System (INIS)
The medical applications of radiation comprise three main fields namely: Diagnostic Radiology, Radiotherapy and Nuclear Medicine. With the new weighting factors of ICRP (IC91a) the effective dose due to medical applications can be established. I is common to separate the effective dose into the genetic part and the somatic part, SED. In dealing with gonad doses it is important to account for the age of the person at the time of exposure as this will influence the number of children still to be expected from that person. The resulting dose will then be called the genetically significant dose, GSD. In a similar fashion this age factor will be important in considering the chance of tumor induction. The age of patients differs considerably from the average age of the general population. This age difference has to be accounted for if a comparison is to be made with other sources of ...
1991-11-01
Lead and calcium distributions in blood, plasma, and milk of the lactating mouse
Energy Technology Data Exchange (ETDEWEB)
Although it has been established that lead is transferred in milk from mother to suckling offspring, the physiological processes and parameters involved are not well understood. Single i.v. doses (0.2 mg/kg) or p.o. doses (2 mg/kg) of radiolabeled lead were administered to lactating and nonlactating female mice, and lead concentrations in blood, plasma, and milk were determined during a 21-day period. Large differences in lead elimination were observed between lactating and nonlactation mice. A significant fraction (25%) of the initial maternal dose (absorbed dose) was transferred to the suckling pups. The ratio of lead concentration in milk to lead concentration in plasma was found to be nearly constant over time. However, the milk-to-blood concentration ratios decreased during the same period. Furthermore, the concentration of lead in milk exceeded the plasma concentration by a ...
1980-01-01
British Library Electronic Table of Contents (United Kingdom)
A convolution/superposition method is proposed for use with primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. It should be noted that the number of energy bins is usually about ten, and that the reconstructed X-ray spectra can reasonably be applied to media with a wide range of effective Z numbers, ranging from water to lead. The study was carried out for 10-MV X-ray doses in water and thorax-like phantoms with the use of open-jaw-collimated fields. The dose calculations were made separately for primary, scatter, and electron contamination dose components, for which we used two extended radiation sources: one was on the X-ray target and the other on the flattening filter. To calculate the in-air beam intensities at po...
2011-01-01
A hydroxide mixture as working fluid for absorption heat pumps
Energy Technology Data Exchange (ETDEWEB)
Basic experimental investigations were carried out with an aqueous solution of a mixture of KOH and NaOH for use as an absorbent in absorption heat pumps. Due to its thermophysical properties this mixture allows temperature lifts from evaporator to absorber of more than 75 K (135 F) in a single-stage absorption chiller. Thermophysical and hydrodynamical properties of the solution were measured. Vapor-liquid-equilibrium data and specific heat capacities were determined for concentrations ranging from 35% up to 75% and temperatures up to 200 C (392 F). From these data the enthalpy of the solution was calculated. Additionally the crystallization temperatures, the density, and the viscosity of the solution were determined. The experimental equipment is described. The data are presented as polynomials and diagrams including experimental accuracy. An apparatus was constructed to measure heat and mass transfer coefficients of the ...
1996-11-01
International Nuclear Information System (INIS)
The purpose of this work was to study and quantify the differences in dose distributions computed with some of the newest dose calculation algorithms available in commercial planning systems. The study was done for clinical cases originally calculated with pencil beam convolution (PBC) where large density inhomogeneities were present. Three other dose algorithms were used: a pencil beam like algorithm, the anisotropic analytic algorithm (AAA), a convolution superposition algorithm, collapsed cone convolution (CCC), and a Monte Carlo program, voxel Monte Carlo (VMC++). The dose calculation algorithms were compared under static field irradiations at 6 MV and 15 MV using multileaf collimators and hard wedges where necessary. Five clinical cases were studied: three lung and two breast cases. We found that, in terms of accuracy, the CCC algorithm ...
2007-07-07
DOE personnel neutron dosimetry evaluation and upgrade program
Energy Technology Data Exchange (ETDEWEB)
The US Department of Energy (DOE) sponsors an extensive research program to improve the methods, dosimeters, and instruments available to DOE facilities for measuring neutron dose and assessing its effects on the work force. The Total Dose Meter was recently developed for measuring in real time the adsorbed dose of mixed neutron and gamma radiation and for calculating the dose equivalent. The Field Neutron Spectrometer was developed to provide a portable instrument for determining neutron spectra in the workplace for flux-to-dose equivalent conversion and quality factor calculation. The Combination Thermoluminescence/Track Etch Dosimeter (TLD/TED) was developed to extend the effective neutron energy range of the conventional TLDs to improve detection of fast-energy neutrons. An Optically Stimulated Luminescence Dosimeter is presently being ...
1988-10-01
International Nuclear Information System (INIS)
With the advent of intensity-modulated radiation therapy (IMRT), the inclusion of heterogeneity corrections is further complicated by the conformal delivery of many small beams forming steep dose gradients. Radiation treatment planning has evolved to take into account even small changes in tissue density so that the dose to tumor can be further optimized. However, different treatment planning systems incorporate different heterogeneity correction algorithms, and it is unclear whether any of these algorithms are superior to others in terms of accurately predicting delivered radiation doses relative to measurement in a clinical setting. The purpose of this study was to determine the accuracy of heterogeneity dose calculations from two widely used IMRT treatment planning systems (Pinnacle and Corvus) against measurement. These two systems handle heterogeneity dose ...
2007-05-01
Tissue Heterogeneity in IMRT Dose Calculation for Lung Cancer
British Library Electronic Table of Contents (United Kingdom)
The aim of this study was to evaluate the differences in accuracy of dose calculation between 3 commonly used algorithms, the Pencil Beam algorithm (PB), the Anisotropic Analytical Algorithm (AAA), and the Collapsed Cone Convolution Superposition (CCCS) for intensity-modulated radiation therapy (IMRT). The 2D dose distributions obtained with the 3 algorithms were compared on each CT slice pixel by pixel, using the MATLAB code (The MathWorks, Natick, MA) and the agreement was assessed with the gamma function. The effect of the differences on dose-volume histograms (DVHs), tumor control, and normal tissue complication probability (TCP and NTCP) were also evaluated, and its significance was quantified by using a nonparametric test. In general PB generates regions of over-dosage both in the l...
2011-01-01
Procedure for radiation dose control in irradiated tissues during electron-beam therapy
International Nuclear Information System (INIS)
The invention refers a procedure of radiation dose control in irradiated tissues during electron-beam therapy. It aims at meeting the planned radiation dose for diseased tissues and taking care of the healthy ones. Therefore, the dose distribution required is determined before irradiation in consideration of such factors as energy-dependence of detector sensitivity, self-absorption within the tissue, and relative biological effectiveness. Furthermore, the expected intensity distribution of secondary quantum radiation excited in the irradiated tissue is calculated. A radiation detector for local resolution is used for registration. During irradiation the calculated intensity distribution is compared with the measured one. The invention is applicable in radiation therapy with monoenergetic electron beams.
1984-11-08
International Nuclear Information System (INIS)
Objective: To establish a computer program for rapid calculation of internal committed effective close through inhalation and ingestion pathways under radiological emergency. Methods: Visual Basic 6.0 is used to compile the generic procedures of internal committed effective dose by inhalation and ingestion in IAEA-TECDOC-1162, Generic Procedures for Assessment and Response during a Radiological Emergency. Results: The assessment methodology of internal committed effective dose by inhalation and ingestion under radiological emergency in the report IAEA-TECDOC-1162 can be coded into a computer program. Conclusions: This research provides a rapid method of assessment for internal committed effective dose by inhalation and ingestion under radiological emergency, and it may provide needed dosimetry data for treatment under emergency response. (authors)
2008-08-01
Validation of WIMS-AECL reactivity device calculations for CANDU reactor
Energy Technology Data Exchange (ETDEWEB)
An important component of the overall program to validate WIMS-AECL for use with RFSP in the analysis of CANDU-6 reactors for design and safety analysis calculations is the validation of calculations of incremental cross sections used to represent reactivity devices. A method has been developed for the calculation of the three-dimensional neutron flux distribution in and around CANDU reactor fuel channels and reactivity control devices. The methods is based on one- and two dimensional transport calculations with the WIMS-AECL lattice cell code, SPH homogenization, and three-dimensional flux calculations with finite-difference diffusion theory using the MULTICELL code. Simulations of Wolsung 1 Phase-B commissioning measurements and Point Lepreau restart tests have been performed, as a part of the program to validate WIMS-AECL lattice cell calculations for ...
1997-06-01
Monte Carlo treatment planning for photon and electron beams
British Library Electronic Table of Contents (United Kingdom)
During the last few decades, accuracy in photon and electron radiotherapy has increased substantially. This is partly due to enhanced linear accelerator technology, providing more flexibility in field definition (e.g. the usage of computer-controlled dynamic multileaf collimators), which led to intensity modulated radiotherapy (IMRT). Important improvements have also been made in the treatment planning process, more specifically in the dose calculations. Originally, dose calculations relied heavily on analytic, semi-analytic and empirical algorithms. The more accurate convolution/superposition codes use pre-calculated Monte Carlo dose "kernels" partly accounting for tissue density heterogeneities. It is generally recognized that the Monte Carlo method is able to increase accuracy even furt...
2007-01-01
International Nuclear Information System (INIS)
The purpose of this work was to study and quantify the differences in dose distributions computed with some of the newest dose calculation algorithms available in commercial planning systems. The study was done for clinical cases where large density inhomogeneities were present. Three dose algorithms were used: a pencil beam like algorithm, the anisotropic analytic algorithm (AAA), a convolution superposition algorithm, collapsed cone convolution (CCC) and a Monte Carlo program, voxel Monte Carlo (VMC++). The dose calculation algorithms were compared under static field irradiations at 6 MV and 15 MV using multileaf collimators and hard wedges where necessary. Five clinical cases were studied: three lung and two breast cases. We found that the CCC algorithm performed overall better than AAA compared to VMC++, but AAA remains an attractive option for routine use ...
2007-06-01
Monte Carlo treatment planning for photon and electron beams
International Nuclear Information System (INIS)
During the last few decades, accuracy in photon and electron radiotherapy has increased substantially. This is partly due to enhanced linear accelerator technology, providing more flexibility in field definition (e.g. the usage of computer-controlled dynamic multileaf collimators), which led to intensity modulated radiotherapy (IMRT). Important improvements have also been made in the treatment planning process, more specifically in the dose calculations. Originally, dose calculations relied heavily on analytic, semi-analytic and empirical algorithms. The more accurate convolution/superposition codes use pre-calculated Monte Carlo dose 'kernels' partly accounting for tissue density heterogeneities. It is generally recognized that the Monte Carlo method is able to increase accuracy even further. Since the second half of the 1990s, several Monte Carlo ...
2007-04-01
TLD array for precise dose measurements in stereotactic radiation techniques
International Nuclear Information System (INIS)
We developed a new TLD array for precise dose measurement and verification of the spatial dose distribution in small radiation targets. It consists of a hemicylindrical, tissue-equivalent rod made of polystyrene with 17 parallel moulds for an exact positioning of each TLD. The spatial resolution of the TLD array was evaluated using the Leskell spherical phantom. Dose planning was performed with KULA 4.4 under stereotactic conditions on axial CT images. In the Leksell gamma unit the TLD array was irradiated with a maximal dose of 10 Gy with an unplugged 14 mm collimator. The doses delivered to the TLDs were rechecked by diode detector and film dosimetry and compared to the computer-generated dose profile. We found excellent agreement of our measured values, even at the critical penumbra decline. For the 14 mm and 18 mm collimator and for the 11 mm collimator ...
1996-12-01
Isochron measurements of naturally irradiated K-feldspar grains
International Nuclear Information System (INIS)
The equivalent doses of K-feldspar grains in a range of grain sizes from 90 to 250#mu#m diameter were measured using a single-aliquot regenerative-dose protocol for the infrared stimulated luminescence (IRSL) signals for two samples of desert sand. The equivalent doses for each sample were compared with that for the 125-150#mu#m grains of quartz from the same samples. The results suggested that the K-feldspar equivalent doses were underestimated because of anomalous fading. Measurements of the decay of the IRSL signals following laboratory irradiation for these two samples, and an additional one from a previously published isochron study, showed anomalous fading during the period of laboratory storage. The decay rate was about 3% per decade for all samples and was independent of the grain size used. Using plots of equivalent doses for K-feldspars as a function of their ...
2007-09-01
International Nuclear Information System (INIS)
After having discussed the peculiarities of children in X-ray diagnosis the application of the effective as well as the mean equivalent doses as to the determination of the radiation exposure in children is represented. In using computerized tomograms to determine position and extent of an organ the exposure by repeated X-raying was calculated referring to the entrance dose. Entrance dose measurements for all types of X-ray examination in hospitals and ascertainments of the frequency of radiograms in 20 X-ray departments were used to determine per capita and collective doses, resp., in several age groups. Alltogether, the per capita dose of children in the GDR amounts to 30% of that of adults. Conclusions were drawn as to taking measures to further reduction of radiation exposure: (1) Technical measures, such as positioning of patients, shielding of organs, ...
1988-01-01
International Nuclear Information System (INIS)
In 16 female patients wick colpourethrocystography was performed directly successively with large-size films as well as medium-size films (intensifier fluorography). The area exposure products were measured by a dosemeter closely attached to the diaphragm and separately for radiography and fluorography, resp. Surface doses as well as organ doses were calculated according to Rosenstein. The average radiatin doses of the active bone marrow were 6.03 mGy for examination with large-size films and 1.27 mGy for fluorography; the average gonadal doses were 7.45 mGy and 1.56 mGy, resp. The portion of fluoroscopy in radiation exposure amounted to 14.8% in large-size film examination, but was 74.0% in medium-size examination. Thus the comparative results revealed a significant reduction of the patient's radiation dose by application of intensifier fluorography in ...
1987-01-01
International Nuclear Information System (INIS)
The accuracy of dose computation within the lungs depends strongly on the performance of the calculation algorithm in regions of electronic disequilibrium that arise near tissue inhomogeneities with large density variations. There is a lack of data evaluating the performance of highly developed analytical dose calculation algorithms compared to Monte Carlo computations in a clinical setting. We compared full Monte Carlo calculations (performed by our Monte Carlo dose engine MCDE) with two different commercial convolution/superposition (CS) implementations (Pinnacle-CS and Helax-TMS's collapsed cone model Helax-CC) and one pencil beam algorithm (Helax-TMS's pencil beam model Helax-PB) for 10 intensity modulated radiation therapy (IMRT) lung cancer patients. Treatment plans were created for two photon beam qualities (6 and 18 MV). For each ...
2006-09-01
Dosimetry of {sup 210}Po in humans, caribou, and wolves in northern Canada
Energy Technology Data Exchange (ETDEWEB)
Effective doses from {sup 210}Po intake with caribou meat were determined for human residents in Baker Lake and Snowdrift in the Northwest Territories of Canada and compared to doses calculated from reported {sup 210}Po tissue activities in Alaskan and British residents. Effective doses were calculated to separate body tissues, using ICRP 60 human weighting factors and the ICRP 30 metabolic model for {sup 210}Po. Baker Lake and Alaskan effective doses were similar at 0.4 mSv y{sup {minus}1} and slightly higher than Snowdrift doses (0.3 mSv y{sup {minus}1}). Alaskan tissue activities indicated higher effective doses to liver, bone surfaces and red marrow and lower doses to spleen than the {sup 210}Po metabolic model (ICRP 1979a) predicts. Effective doses to Baker Lake and ...
1994-06-01
International Nuclear Information System (INIS)
Background and purpose: The low density of lung tissue causes a reduced attenuation of photons and an increased range of secondary electrons, which is inaccurately predicted by the algorithms incorporated in some commonly available treatment planning systems (TPSs). This study evaluates the differences in dose in normal lung tissue computed using a simple and a more correct algorithm. We also studied the consequences of these differences on the dose-effect relations for radiation-induced lung injury. Materials and methods: The treatment plans of 68 lung cancer patients initially produced in a TPS using a calculation model that incorporates the equivalent-pathlength (EPL) inhomogeneity-correction algorithm, were recalculated in a TPS with the convolution-superposition (CS) algorithm. The higher accuracy of the CS algorithm is well-established. Dose distributions in lung were compared using isodoses, ...
2003-10-01
Monte Carlo calculations using the codes PENELOPE and GEANT4 have been performed to characterize the dosimetric parameters of the new 20 mm long catheter based $^{32}$P beta source manufactured by Guidant Corporation. The dose distribution along the transverse axis and the two dimensional dose rate table have been calculated. Also, the dose rate at the reference point, the radial dose function and the anisotropy function were evaluated according to the adapted TG-60 formalism for cylindrical sources. PENELOPE and GEANT4 codes were first verified against previous results corresponding to the old 27 mm Guidant $^{32}$P beta source. The dose rate at the reference point for the unsheathed 27 mm source in water was calculated to be $0.215 \\pm 0.001$ cGy s$^{-1}$ mCi$^{-1}$, for PENELOPE, and $0.2312 \\pm 0.0008$ cGy s$^{-1}$ ...
2003-01-01
Energy Technology Data Exchange (ETDEWEB)
This study evaluates the effect of gamma radiation on the viability of fungi and actinomycetes that contaminate medicinal plants. The relationship between the total lipids of some fungi and actinomycetes and their sensitivity to gamma radiation is also investigated. The data reveal that the viable counts of these florae decrease approximately exponentially with the radiation dose, the effective dose for the elimination of these microorganisms being about 5 kGy for all the medicinal plants under study. Response of pure cultures of fungi and actinomycetes isolated from medicinal plants to increasing absorbed doses of gamma radiation indicate that an increase in radioresistance is in the following order: Streptomyces rimosus, Fusarium solani, Nocardia kuroishii. F. oxysporum, A. fumigatus, A. flavus, A. parasiticus and A. ochraceus. The total lipid contents of molds and actinomycetes have been reported to ...
1997-01-01
Energy Technology Data Exchange (ETDEWEB)
The study compares the doses absorbed by the dentomaxillary area in spiral CT and panoramic examinations. The dose measurements demonstrate that patients receive smaller doses with panoramic radiography than with spiral CT with Dentascan. After following for some variations from instrumental differences, they are in substantial agreement with literature data. Further investigations are needed considering the radiobiological risk related to the growing spread of Dentascan examinations. [Italian] Questo lavoro intende confrontare le dosi assorbite nel distretto dento-mascellare, con le due principali tecniche utilizzate in questo campo: TC spirale e ortopantomografia. Emerge come l'esame panoramico delle arcate dentarie eseguito con l'ortopantomografo comporti la'ssorbimento di dosi inferiori rispetto a quelle dell'esame TC spirale con programma Dentascan. Questi dati, ...
1999-05-01
International Nuclear Information System (INIS)
Dairy products doubly labeled with 45Ca and 47Ca were used to evaluate an extrinsic labeling procedure for calcium bioavailability determination. Nonfat milk, yogurt, and fresh cheese curd were prepared from caprine milk that was intrinsically labeled with 45Ca. The products were then labeled extrinsically with 47Ca and administered to rats by gavage. The 47Ca to 45Ca ratio in bone and teeth averaged about 1.00 with either milk, yogurt, or CaCl2, but the ratio was about 1.04 when dosed with cheese curd. Ca absorption, determined by whole-body counting of 47Ca, was lower (P less than 0.05) in cheese curd (59%) than in either milk (69%), yogurt (72%), or CaCl2 (72%). Expressed as percent of dose, the absorption of 47Ca was highly correlated with bone 47Ca (r = 0.973) and with bone 45Ca (r = 0.946). Correlation between tibia 47Ca and tibia 45Ca was r = 0.923. For the dairy products tested, our results indicated that extrinsic 47Ca was ...
The application of Geant4 simulation code for brachytherapy treatment
Brachytherapy is a radiotherapeutic modality that makes use of radionuclides to deliver a high radiation dose to a well-defined volume while sparing surrounding healthy structures. At the National Institute for Cancer Research of Genova a High Dose Rate remote afterloading system provides Ir(192) endocavitary brachytherapy treatments. We studied the possibility to use the Geant4 Monte Carlo simulation toolkit in brachytherapy for calculation of complex physical parameters, not directly available by experiment al measurements, used in treatment planning dose deposition models.
2000-01-01
Radiation exposure of patients and operators during interventional radiology
International Nuclear Information System (INIS)
Surface doses received by patients and operators were measured during 30 interventional radiological procedures (ten percutaneous transhepatic biliary drainages, ten percutaneous nephrostomies, ten percutaneous transluminal angioplasties). In addition, organ doses to the patient were determined using an Alderson-Rando phantom. These served as a basis for calculating the so-called somatic dose indices. It was found that the somatic radiation risk to the patient is relatively small despite prolonged periods of fluoroscopy. However, exposure of the hands and lenses of the operator could easily reach the limits thought acceptable while carrying out these procedures with additional angiography. (orig).
1986-01-01
Radiation doses from flying through nuclear-debris clouds. Final report, 2-10 January 1985
Energy Technology Data Exchange (ETDEWEB)
Taboada et al. have recently developed a computer model to predict gamma radiation doses to aircrews flying through nuclear-debris clouds. Although the model has the advantages of taking a large number of parameters into account and using the benchmark DELFIC code to model cloud dynamics, it takes up to 20 min for a single run on a mainframe computer. Results from a number of runs have been generalized into empirical formulae. From these results it is possible to estimate worst case gamma radiation doses for complex scenarios using a hand calculator.
1986-04-01
Accumulation and distribution of "8"5Kr in rats exposed to "8"5Kr atmospheres
International Nuclear Information System (INIS)
Retention kinetics and tissue partition coefficients for "8"5Kr were determined in rats exposed to known concentrations of "8"5Kr gas. The tissue partition coefficients were used to calculate the relative tissue radiation dose, assuming exposure conditions equivalent to the maximum permissible concentration in air (MPC)a. The estimated radiation dose was highest in adrenals and body fat, about twice the dose estimated for the next highest tissue, ovaries. Saturation and desaturation curves show that the contents of the large intestines have a prolonged desaturation time compared to other samples analyzed.
1977-05-01
A dose computation algorithm used in MLC conformal treatment
International Nuclear Information System (INIS)
A dose calculation algorithm for MLC based conformal radiotherapy is described in this paper. The algorithm is formulated by the coordinate of MLC leaves. Verification on the algorithm is made by comparing the dose distributions generated by this algorithm with that generated by a Differential Convolution Superposition algorithm for various regular and irregular fields. The results demonstrate that the present algorithm has suitable accuracy and high computational efficiency, thus it could be useful for the treatment planning process in MLC based conformal radiotherapy, where the workload for interactively or automatically designing the shapes of MLC is heavy. (authors)
2007-12-01
International Nuclear Information System (INIS)
the cotton leaf worm, Spodoptera littoralis (boisd.) were irradiated with 100,150 and 200 Gy to induce inherited sterility. the effects of the tested doses applied to these pupae through three consequent fillial generations and the retarded influence on their F_1,F_2 and F_3 generations progeny were examined . irradiation of parental male induced damage to their daughter females ovaries. the overioles of females among P_1 ,F_1 and F_2 generations showed that the follicular epithelial cells appeared abnormal beside their limited separation from developing oocytes which became shrinked, semi absorbed or completely absorbed leaving vacuoles. the nurse cells were reduced or absent in some parts. damage was obvious through the first and second generations especially at 150 and 200 Gy. in the third generation, ovaries were not greatly affected
2004-02-01
International Nuclear Information System (INIS)
Magnetic particles (MAG*SEP"S"M) coated with various absorbents were evaluated for the separation and recovery of low concentrations of cesium from nuclear waste solutions. The MAG*SEP"S"M particles were coated with (1) clinoptilolite, (2) transylvanian volcanic tuff, (3) resorcinol formaldehyde, and (4) crystalline silico-titanate, and then were contacted with a Hanford supernatant simulant. Particles coated with the crystalline silico-titanate were identified by Bradtec as having the highest capacity for cesium removal under the conditions tested (variation of pH, ionic strength, cesium concentration, and absorbent/solution ratio). The MAG*SEP"S"M particles coated with resorcinol formaldehyde had high distribution ratios values and could also be used to remove cesium from Hanford supernant simulant. Gamma irradiation studies were performed on the MAG*SEP"S"M particles with a gamma dose equivalent to 100 cycles of use. ...
1994-05-09
Monte Carlo calculations of proton irradiation of permanent magnets for the TRADE experiment have been performed. An irradiation dose of about 4´106 Gy/yr/mA has been estimated due to beam losses in normal operating conditions. Existing experimental results indicate that this irradiation level may induce a considerable demagnetization: in fact, a dose of 6´107 Gy induces a remanence loss of 0.3 % on samples of Sm2Co17 magnets, which are the most resistant type. More detailed calculations with the final design of the magnets and of the beam line are suggested, to determine if the irradiation levels allowed a reliable operation of the permanent magnets for the entire duration of the TRADE experiment. Damage and gas production rates have also been calculated; the values obtained are very low, thus confirming that the demagnetization process is in great part reversible.
2002-01-01
Implementation of FFT convolution and multigrid superposition models in the FOCUS RTP system
International Nuclear Information System (INIS)
In radiotherapy treatment planning, convolution/superposition algorithms currently represent the best practical approach for accurate photon dose calculation in heterogeneous tissues. In this work, the implementation, accuracy and performance of the FFT convolution (FFTC) and multigrid superposition (MGS) algorithms are presented. The FFTC and MGS models use the same 'TERMA' calculation and are commissioned using the same parameters. Both models use the same spectra, incorporate the same off-axis softening and base incident lateral fluence on the same measurements. In addition, corrections are explicitly applied to the polyenergetic and parallel kernel approximations, and electron contamination is modelled. Spectra generated by Monte Carlo (MC) modelling of treatment heads are used. Calculations using the MC spectra were in excellent agreement with measurements for many linear accelerator types. To ...
2000-04-01
Radiation doses in adults and children in standardized diagnostic radiology
International Nuclear Information System (INIS)
For comparison of radiation exposure and risk in different diagnostic procedures for adults and children dose measurements and calculations of organs with special risk were carried out. Parameters of image formation influencing image quality as well as of exposure concerning infants and children are recorded and discussed as to radiation exposure and protection. Conclusions are drawn with respect to systems of image formation and to standards of examination and quality assurance.
1987-01-01
Radial distribution of dose and cross-sections for the inactivation of dry enzymes and viruses
International Nuclear Information System (INIS)
A new semi-empirical algorithm for the radial distribution of dose is compared with available data. The algorithm is used to calculate the inactivation cross section for dry enzymes and viruses using an extended target model of a 1-hit detector. Agreement with data is at about the 15% level, approximating the precision of the data itself. (author).
1985-05-01
International Nuclear Information System (INIS)
Concentrations of 226Ra, 232Th, and 40K measured in bauxite waste, local building materials, and soils are presented and used in model equations to estimate the effective gamma dose-equivalent increments over background in the center of a standard-sized room in a prototype house. Calculated and measured values compare reasonably well.
Interinstitutional Variations in Planning for Stereotactic Body Radiation Therapy for Lung Cancer
International Nuclear Information System (INIS)
Purpose: The aim of this study was to assess interinstitutional variations in planning for stereotactic body radiation therapy (SBRT) for lung cancer before the start of the Japan Clinical Oncology Group (JCOG) 0403 trial. Methods and Materials: Eleven institutions created virtual plans for four cases of solitary lung cancer. The created plans should satisfy the target definitions and the dose constraints for the JCOG 0403 protocol. Results: FOCUS/XiO (CMS) was used in six institutions, Eclipse (Varian) in 3, Cadplan (Varian) in one, and Pinnacle3 (Philips/ADAC) in one. Dose calculation algorithms of Clarkson with effective path length correction and superposition were used in FOCUS/XiO; pencil beam convolution with Batho power law correction was used in Eclipse and Cadplan; and collapsed cone convolution superposition was used in Pinnacle3. For the target volumes, the overall coefficient of variation was 16.6%, and the ...
2007-06-01
Design parameters for tube cavity receivers in solar power plants
Energy Technology Data Exchange (ETDEWEB)
The design of a solar heated cavity receiver transferring 60 MW of thermal energy to the working medium (air) for a closed-cycle gas turbine is described. The gas turbine plant with its cycle layout is presented. Then the tubes for the receiver are designed taking into account thermal and mechanical loads. It is shown how the occurring stresses are influenced by the destribution of the locally absorbed hat flux. Calculations for an existing coal fired air heater of a closed-cycle gas turbine give a first impression of the long-term behaviour to be expected of the receiver tubes.
1981-01-01
Convection heat loss from a cavity receiver
Energy Technology Data Exchange (ETDEWEB)
The receiver whose convective heat loss test results are presented was designed to absorb 5 MW of solar energy, using a molten salt working fluid. During the tests, this receiver was brought to a temperature of about 343 C by a small group of heliostats. Total receiver heat loss due to emitted radiation, conduction and convection was first determined, and the convection loss was established by calculating the radiation and conduction losses analytically and subtracting their sum from the total. Losses due to convection are found to be 1.43 percent of the total heat input.
1984-02-01
Energy Technology Data Exchange (ETDEWEB)
The performance of a solar chemical heat pipe was studied using CO{sub 2}reforming of methane as the endothermic reaction. A directly heated vertical reactor, packed with a rhodium catalyst was used. The solar tests were carried out in the Schaeffer solar furnace of the Weizmann Institute of Science. The power absorbed was up to 6.3 KW, the maximal flow rates of the gases reached 11,000 1/h, and the methane conversions reached 85%. A computer model was developed to simulate the process. Agreement of the calculations with the experimental results was quite satisfactory.
1992-01-01
A mathematical model for simulating shallow solar ponds for treatment of industrial wastewater
Energy Technology Data Exchange (ETDEWEB)
This paper presents a mathematical model to analyze the solar evaporation in a shallow pond in steady state, when the inlet flow rate, concentration, surface area and solar radiation are given. The simultaneous heat and mass transfer mechanisms are considered for quantifying the amount of evaporated water to the atmosphere and the actual absorbed heat by wastewater is calculated to obtain the bottom temperature of water pond. The heat losses to air by radiation and convection mechanisms are considered and the heat transmission across the water film is evaluated by the forced convection mechanism. 6 refs., 5 figs., 1 tab.
1996-12-31
Neon-20 depth-dose relations in water
Energy Technology Data Exchange (ETDEWEB)
The dose from heavy ion beams has been calculated using a one-dimensional transport theory and evaluated for 670 MeV/amu /sup 20/Ne beams in water. The result is presented so as to be applicable to arbitrary ions for which the necessary interaction data are known. The present evaluation is based on the Silberberg-Tsao fragmentation parameters augmented with light fragment production from intranuclear cascades, recently calculated nuclear absorption cross sections, and evaluated stopping power data. Comparison with recent experimental data obtained at the Lawrence Berkeley Laboratory reveals the need for more accurate fragmentation data.
1984-05-01
International Nuclear Information System (INIS)
Dose calculations for radiation arc therapy are traditionally performed by approximating continuous delivery arcs with multiple static beams. For 3D conformal arc treatments, the shape and weight variation per degree is usually small enough to allow arcs to be approximated by static beams separated by 5"0-10"0. But with intensity-modulated arc therapy (IMAT), the variation in shape and dose per degree can be large enough to require a finer angular spacing. With the increase in the number of beams, a deterministic dose calculation method, such as collapsed-cone convolution/superposition, will require proportionally longer computational times, which may not be practical clinically. We propose to use a homegrown Monte Carlo kernel-superposition technique (MCKS) to compute doses for rotational delivery. The IMAT plans were generated with 36 static beams, which were ...
2008-09-07
International Nuclear Information System (INIS)
The distribution of radiation dose commitments within the body that can result from the lung deposition of a number of transuranic radionuclides ("2"3"7Pu, "2"3"8Pu, "2"3"9Pu, "2"4"0Pu, "2"4"1Pu, "2"4"2Pu, "2"4"3Pu, "2"4"4Pu, "2"4"1Am, "2"4"2Am, "2"4"3Am, "2"4"4Am, "2"4"2Cm, "2"4"3Cm, "2"4"4Cm, and "2"4"6Cm) was calculated. The variables that influence these organ dose commitments include the mobility of the particle or its dissolution products within the body, the radiation characteristics of the inhaled radionuclides and their progeny, and the size of the particles inhaled. In the calculation of organ dose commitments for whole-body, lungs, liver, bone tissues, kidneys, and gastrointestinal tract from the inhalation of transuranium radionuclides, physical characteristics of importance are the dimensions of the particle, its aerodynamic properties, and its density. For particles ...
1975-11-17
The denoising of Monte Carlo dose distributions using convolution superposition calculations
International Nuclear Information System (INIS)
Monte Carlo (MC) dose calculations can be accurate but are also computationally intensive. In contrast, convolution superposition (CS) offers faster and smoother results but by making approximations. We investigated MC denoising techniques, which use available convolution superposition results and new noise filtering methods to guide and accelerate MC calculations. Two main approaches were developed to combine CS information with MC denoising. In the first approach, the denoising result is iteratively updated by adding the denoised residual difference between the result and the MC image. Multi-scale methods were used (wavelets or contourlets) for denoising the residual. The iterations are initialized by the CS data. In the second approach, we used a frequency splitting technique by quadrature filtering to combine low frequency components derived from MC simulations with high frequency components derived from CS components. ...
2007-09-07
Estimation of population doses from medical uses of radiopharmaceuticals in Japan, 1977, 2
International Nuclear Information System (INIS)
Population doses from diagnostic and therapeutic uses of radiopharmaceuticals have been estimated on the basis of a nation wide survey data on the number of investigations and treatments used radiopharmaceuticals in the nuclear medicine and the annual amount of their activities. The gonad and marrow doses were calculated from published biokinetics data from humans, employing the MIRD method. The resultant annual genetically significant dose from diagnostic and therapeutic uses of radiopharmaceuticals was 0.36 and 0.02 mrad (3.6 and 0.2 #mu#Gy) per person, respectively, with a total 0.38 mrad (3.8 #mu#Gy) per person. The annual per Caput mean bone marrow dose was 2.3 mrad (23 #mu#Gy) for diagnosis and 0.2 mrad (2 #mu#Gy), for therapy. The resultant annual leukemia significant dose was 1.8 mrad (18 #mu#Gy) per person for diagnostic uses and 0.2 mrad (2 #mu#Gy) per ...
1979-01-01
Estimations of population doses and risk estimates from occupational exposures in Japan, 1978, 2
International Nuclear Information System (INIS)
The population doses and risks of stochastic effects from occupational exposures in Japan in 1978 were estimated on the basis of a nation-wide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 82,500 workers other than the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the offitial publication of the Japan Nuclear Safety Commission. The total number of workers except for nuclear power stations was estimated to be about 170,000 persons. Radiation works were subdivided as follows: medical works including dental; nondestructive inspectional; non-atomic energy industrial; research and educational; atomic energy industrial and nuclear power industrial. The annual collective dose equivalents were estimated to be about 6,000 man rem for medical workers, 450 man rem for non-destructive inspectional, ...
1981-01-01
International Nuclear Information System (INIS)
In the early period after the Chernobyl accident, analysis of patterns of "1"3"1I exposure of the human thyroid showed that contaminated milk was the basic source of "1"3"1I intake among the inhabitants of Russia. The equipment and techniques used for measurement of the "1"3"1I content in the thyroids of these individuals are described in this work. A model of the "1"3"1I intake, taking into account protective actions, and a method of thyroid dose calculation are discussed. The mean thyroid dose and frequency distributions of the thyroid doses to inhabitants of towns and villages of the Bryansk, Tula and Orel regions of Russia are presented. The mean dose to the thyroids of children living in the villages was 2 to 5 times higher than the dose to adult thyroids; for children living in the towns, the mean dose was 1.5 to 12 times higher. The ...
Clinical implementation of a convolution based algorithm for 3D treatment planning
International Nuclear Information System (INIS)
Purpose/Objective: With the advent of computed tomography and magnetic resonance imaging, the three dimensional representation of the patient anatomy has become an invaluable resource for better diagnosis and delineation of the target volume and sensitive structures in radiation therapy. Although the therapeutic linear accelerator industry has made available highly sophisticated equipment, the aggressiveness in dose prescription and delivery has to be complimented by accurate dose computation methods. We have adopted a convolution/superposition algorithm for the calculation of absolute dose that fully accounts for the external shape and internal structure of the patient for photon treatment radiotherapy. In this paper, we will discuss the principles of the convolution algorithm and we will show how the computed dose compares to clinically relevant treatment techniques. Materials and ...
On the two-loop Yukawa corrections to the MSSM Higgs boson masses at large tan(beta)
We complete the effective potential calculation of the two-loop, top/bottom Yukawa corrections to the Higgs boson masses in the Minimal Supersymmetric Standard Model, by computing the O(at^2 + at*ab + ab^2) contributions for arbitrary values of the bottom Yukawa coupling. We also compute the corrections to the minimization conditions of the effective potential at the same perturbative order. Our results extend the existing O(at^2) calculation, and are relevant in regions of the parameter space corresponding to tan(beta) >> 1. We extend to the Yukawa corrections a convenient renormalization scheme, previously proposed for the O(ab*as) corrections, that avoids unphysically large threshold effects associated with the bottom mass and absorbs the bulk of the corrections into the one-loop expression. For large values of tan(beta), the new contributions can account for a variation of several GeV in the lightest Higgs boson ...
2003-01-01
Energy Technology Data Exchange (ETDEWEB)
It was developed a new formulation of macro aggregates of Samarium 153 ({sup 153} Sm-MH) for the arthropaties treatment. The radio pharmaceutic was prepared by reaction of Samarium 153 chloride (SmCl{sub 3}) in aqueous environment with sodium boron hydride in NaOH 0.5 N. The microscopic analysis shown that the particles have an average size of 4% m (range 1-14 {mu} m). The velocity of sedimentation was 0.008 cm/min with high stability in vitro in human serum. The biological studies in healthy rabbits, shown that the complex is retained inside the articulation still eight days after of the administration of the radiopharmaceutical. Likewise, it is presented the data of absorbed dose in the different target organs, which was determined by thermoluminescent dosimetry (TLD) through the use of a REMCAL phantom (radiation equivalent manikin calibration). (Author)
1999-07-01
Irradiation of polyethylene in the presence of antioxidants
International Nuclear Information System (INIS)
The radiation induced reactions in LDPE in the presence of phenolic type antioxidants have been studied. It was shown that various antioxidants can influence the polyethylene network formation and the radical yield in different ways. The dependence of network structure on absorbed doses was determined by gel analysis, hot-set test and extraction of antioxidants for samples irradiated with accelerated electrons. It was found that the antioxidants eluted from polyethylene in higher percentage influence polymer crosslinking to a smaller degree. The ESR studies of #gamma#-irradiated blends of polyethylene with antioxidant indicate the presence of alkyl and phenoxyl radicals. The role of antioxidant molecules on radiation induced reactions in polyethylene-antioxidant systems is considered. The correlation between the network structure and the type of additive in polyethylene is also discussed. (author).
Energy Technology Data Exchange (ETDEWEB)
With the exception of the 1945 Hiroshima and Nagasaki nuclear weapon explosions and the 1986 Tchernobyl reactor accident, most of the radiation accidents concerns the medical and the traditional industrial sectors. The seriousness of the accident is directly function of the absorbed dose. The paper, first, gives the definition of a radiologic accident with its specific criteria and pathological manifestations. Then, some famous historical accidents are reviewed from the discovery of X-rays to recent acute irradiations due to the careless manipulation of radiation sources. From this analysis, three main causes are put forward: the dysfunction of nuclear medicine apparatuses, the victims` lack of training and knowledge of the risks, and the non-identification or the loss of radiation sources. (J.S.). 1 photo.
1996-04-01
CSSX Radiolytic H2 Generation ("Thermolysis") -- Final Report
Energy Technology Data Exchange (ETDEWEB)
The purpose of this work was to determine the radiolytic hydrogen gas yield of irradiated CSSX solvent at several temperatures. The active ingredient of this solvent is calix[4]arene-bis-(t-octylbenzo) crown-6, a calixarene crown ether used for cesium complexation. The solvent also contains 1-(2,2,3,3-tetrafluoropropoxy)-3-(4-sec-butylphenoxy)-2-propanol, a fluorinated alcoholic solvent modifer used to improve the solubility of the calixarene and its cesium complex in the Isopar L diluent. Isopar L is a branch-chain alkane and comprises most of the mixture. Samples of this solution were irradiated to various absorbed ?-ray doses in gas-tight sample containers, which were then sampled for hydrogen gas content. The methods are described below.
2009-01-01
A TLD powder dosimetry measurement system for physical models of reference man
International Nuclear Information System (INIS)
A tissue-equivalent dosimetry system has been developed for use in absorbed dose determinations with physical models of Reference Man. The dosimeter used was a thermo-luminescent dosimeter (TLD) powder which was mixed with a 'tissue-equivalent' material and modeled to closely approximate an organ's geometry and absorption properties. A separation procedure was developed by which the TLD powder was washed and the 'tissue-equivalent' material, a wax, was dissolved and extracted following the irradiation of the model. The procedure was tested to determine losses of powder, homogeneity of the powder's distribution throughout the wax, the effects of the separation procedure upon the powder and the statistical behavior of the procedure. The results of these tests established the feasibility of the procedure. A full-scale model of the pancreas was tested and the results supported the validity of the technique. (author)
1978-12-01
Energy Technology Data Exchange (ETDEWEB)
Purpose: calculation of conversion coefficients for the reconstruction of organ doses from entrance doses for abdomen radiographs of 0, 1, 5, 10, 15, and 30-year-old patients in conventional pediatric radiology for the radiographic settings recommended by the German and European guidelines for quality management in diagnostic radiology. Materials und method: using the commercially available personal computer program PCXMC developed by the Finnish Center for Radiation and Nuclear Safety (Saeteilyturvakeskus STUK), conversion coefficients for conventional abdomen radiographs were calculated performing Monte Carlo simulations in mathematical hermaphrodite phantom models describing patients of different ages. The possible clinical variation of beam collimation was taken into consideration by defining optimal and suboptimal radiation fields on the phantoms' surfaces. Results: conversion coefficients ...
2009-10-15
Energy Technology Data Exchange (ETDEWEB)
The real-time dose assessment system under development has been updated and the technology for tracer experiment has been established. The calculation of external gamma dose is the most difficult and time-consuming part of the dose calculations. The characteristics of external gamma exposure have been investigated and the method for reducing the calculation time has been devised. The internal exposure via the ingestion of the contaminated foodstuffs is one of the important pathways to the total radiological exposure. In the emergency, it is necessary to take an action such like food ban to protect the internal exposure. An algorithm for the interface between the real-time system and the food chain model has been provided. The second field tracer experiment over flat terrain has been carried out on a plain in Iksan city in Junrabook-Do. Sequential tracer sampler ...
1995-07-01
Energy Technology Data Exchange (ETDEWEB)
We have updeated the radiological dose assessment for Enjebi Island at Enewetak Atoll using data derived from analysis of food crops grown on Enjebi. This is a much more precise assessment of potential doses to people resettling Enjebi Island than the 1980 assessment in which there were no data available from food crops on Enjebi. Details of the methods and data used to evaluate each exposure pathway are presented. The terrestrial food chain is the most significant potential exposure pathway and /sup 137/Cs is the radionuclide responsible for most of the estimated dose over the next 50 y. The doses are calculated assuming a resettlement date of 1990. The average wholebody maximum annual estimated dose equivalent derived using our diet model is 166 mremy;the effective dose equivalent is 169 mremy. The estimated 30-, 50-, and 70-y integral ...
1987-07-01
Verification of the Gaspar dose assessment module used in Maxigasp and Popgasp
Energy Technology Data Exchange (ETDEWEB)
The GASPAR module utilized in MAXIGASP and POPGASP has been verified by hand calculations. The program operates as documented by the NRC [Eckerman et. al. 1980]. Equations used in the code to calculate downwind deposition rates, concentrations in air, on ground surfaces, and in vegetables, meat, and milk are provided in this report.
1992-12-31
IMRT verification by three-dimensional dose reconstruction from portal beam measurements
International Nuclear Information System (INIS)
A method of reconstructing three-dimensional, in vivo dose distributions delivered by intensity-modulated radiotherapy (IMRT) is presented. A proof-of-principle experiment is described where an inverse-planned IMRT treatment is delivered to an anthropomorphic phantom. The exact position of the phantom at the time of treatment is measured by acquiring megavoltage CT data with the treatment beam and a research prototype, flat-panel, electronic portal imaging device. Immediately following CT imaging, the planned IMRT beams are delivered using the multiple-static field technique. The delivered fluence is sampled using the same detector as for the CT data. The signal measured by the portal imaging device is converted to primary fluence using an iterative phantom-scatter estimation technique. This primary fluence is back-projected through the previously acquired megavoltage CT model of the phantom, with inverse attenuation correction, to yield an input fluence map. The ...
2002-08-01
Energy Technology Data Exchange (ETDEWEB)
CT-Expo is a novel MS Excel application for assessing the radiation doses delivered to patients undergoing CT examinations, based on computational methods that were used to analyze the data collected in the German survey on CT practice in 1999. The program enables the calculation of all dose quantities of practical value, such as axial dose free-in-air, weighted CTDI, dose-length product, effective dose and uterine dose. In contrast to existing programs for CT dose assessment, CT-Expo offers a number of unique features, such as gender-specific dose calculation for all age groups (adults, children, newborns), applicability to all existing scanner models including correction of scanner-specific influences, and the possibility of comparison with the results from the German CT survey ...
2002-12-01
Therapeutic Applications of Monte Carlo Calculations in Nuclear Medicine
This book examines the applications of Monte Carlo (MC) calculations in therapeutic nuclear medicine, from basic principles to computer implementations of software packages and their applications in radiation dosimetry and treatment planning. It is written for nuclear medicine physicists and physicians as well as radiation oncologists, and can serve as a supplementary text for medical imaging, radiation dosimetry and nuclear engineering graduate courses in science, medical and engineering faculties. With chapters is written by recognised authorities in that particular field, the book covers the entire range of MC applications in therapeutic medical and health physics, from its use in imaging prior to therapy to dose distribution modelling targeted radiotherapy. The contributions discuss the fundamental concepts of radiation dosimetry, radiobiological aspects of targeted radionuclide therapy and the various components and steps required for ...
2003-01-01
Monte Carlo calculations using the codes PENELOPE and GEANT4 have been performed to characterize the dosimetric properties of monoenergetic photon point sources in water. The dose rate in water has been calculated for energies of interest in brachytherapy, ranging between 10 keV and 2 MeV. A comparison of the results obtained using the two codes with the available data calculated with other Monte Carlo codes is carried out. A chi2-like statistical test is proposed for these comparisons. PENELOPE and GEANT4 show a reasonable agreement for all energies analyzed and distances to the source larger than 1 cm. Significant differences are found at distances from the source up to 1 cm. A similar situation occurs between PENELOPE and EGS4.
2006-01-01
Cobalt release from PCA steel during possible fusion reactor accidents
Energy Technology Data Exchange (ETDEWEB)
Possible accident scenarios for a fusion reactor include breaches in the vacuum or cooling system. Intruding air or steam could react with structural or plasma facing materials, possibly mobilizing radioactive isotopes. Safety assessments must consider the early dose at the site boundary from the release of these activated materials. Previous calculations have indicated that cobalt isotopes dominate dose calculations for designs using stainless steel. Values used in these calculations, however, had been largely determined by the measurement limits of the chemical analysis methodology instead of measured releases. The purpose of the current study was to refine the analytical method to reduce the limit for detecting cobalt, and then test PCA steel in air and steam between 973 and 1473 K. Goals were to obtain more accurate measurements of cobalt mobilization in terms of g/m{sup ...
1995-01-01
A revised dosimetric model of the adult head and brain
Energy Technology Data Exchange (ETDEWEB)
During the last decade, new radiopharmaceutical have been introduced for brain imaging. The marked differences of these tracers in tissue specificity within the brain and their increasing use for diagnostic studies support the need for a more anthropomorphic model of the human brain and head. Brain and head models developed in the past have been only simplistic representations of this anatomic region. For example, the brain within the phantom of MIRD Pamphlet No. 5 Revised is modeled simply as a single ellipsoid of tissue With no differentiation of its internal structures. To address this need, the MIRD Committee established a Task Group in 1992 to construct a more detailed brain model to include the cerebral cortex, the white matter, the cerebellum, the thalamus, the caudate nucleus, the lentiform nucleus, the cerebral spinal fluid, the lateral ventricles, and the third ventricle. This brain model has been included within a slightly modified version of the head model developed by ...
1996-06-01
A revised dosimetric model of the adult head and brain
International Nuclear Information System (INIS)
During the last decade, new radiopharmaceutical have been introduced for brain imaging. The marked differences of these tracers in tissue specificity within the brain and their increasing use for diagnostic studies support the need for a more anthropomorphic model of the human brain and head. Brain and head models developed in the past have been only simplistic representations of this anatomic region. For example, the brain within the phantom of MIRD Pamphlet No. 5 Revised is modeled simply as a single ellipsoid of tissue With no differentiation of its internal structures. To address this need, the MIRD Committee established a Task Group in 1992 to construct a more detailed brain model to include the cerebral cortex, the white matter, the cerebellum, the thalamus, the caudate nucleus, the lentiform nucleus, the cerebral spinal fluid, the lateral ventricles, and the third ventricle. This brain model has been included within a slightly modified version of the head model developed by ...
1996-07-21
International Nuclear Information System (INIS)
Full text: Verification of the dose delivered to a patient during radiotherapy is an important quality assurance procedure, however this is rarely performed due to the extra time involved. Electronic portal images (EPIs) are currently acquired at many centres during radiotherapy treatment for positioning verification. These could be utilised for dose verification provided 1) an accurate prediction of the dose transmitted through the patient to the EPID can be produced for the patients' radiotherapy beams, and, 2) the EPID image can be converted to an accurate measured dose. Ideally, the radiotherapy planning system (RTPS) would be used to produce the predicted dose as part of the planning procedure. The aim of this project is to investigate whether the convolution-superposition model of the Pinnacle RTPS can accurately calculate dose ...
2004-12-01
Discrepancies in molar extinction coefficients of Fe"3"+ in Fricke dosimetry
International Nuclear Information System (INIS)
Values of the chemical yield, G, and of the molar extinction coefficient, epsilon, for Fricke dosimetry, have been recommended by ICRU. For epsilon, the value in ICRU Reports 17 and 21, 2205 1.mol"-"1.cm"-"1, based on an analysis of 83 reported values. It was suggested that, where neither a careful wavelength calibration nor absorbance linearity checks had been performed, a standard error of 1.5% should be assumed; otherwise 0.15% could be accepted. Alternatively, the accuracy in applying this chemical dose meter was considered improved if there was an independent determination of epsilon with the same spectrophotometer as was used for the determination of the optical density of irradiated Fricke solution. The accuracy claimed for both methods remains questionable, since no complete argumentation could be given for the differences of up to 13% in the published values. Taking into account the discussion of the sources of error by Bryant, ...
1977-12-09
Pharmacokinetic and dosimetric characteristics of some thallium isotopes
International Nuclear Information System (INIS)
Pharmacokinetics is studied, radiation doses to patients when using domestic thallium-201 chloride in diagnosis of the heart ischemic disease is estimated; contribution into the total dose of thallium-201 (1.5 %), thallium-201 (0.2 %) and lead-201 + lead-203 (0.05 %) radionuclide impurities is also determined. Internal doses were estimated for a heterogeneous phantom of a standard man; the calculations were carried out using a computer. Scanning of patients which were treated with radiopharmaceuticals to be diagnosed was carried out using a whole body counter and gamma-chamber. Large intestine, kidneys and thyroid are the critical organs when using thallium-201 chloride. The highest contribution into the dose to organs and the whole body from thallium-200 and thallium-202 impurities being contained in thallium-201, doesn't exceed 8.6 %. The contribution into the ...
Verification of maximum impact force for interim storage cask for the Fast Flux Testing Facility
Energy Technology Data Exchange (ETDEWEB)
The objective of this paper is to perform an impact analysis of the Interim Storage Cask (ISC) of the Fast Flux Test Facility (FFTF) for a 4-ft end drop. The ISC is a concrete cask used to store spent nuclear fuels. The analysis is to justify the impact force calculated by General Atomics (General Atomics, 1994) using the ILMOD computer code. ILMOD determines the maximum force developed by the concrete crushing which occurs when the drop energy has been absorbed. The maximum force, multiplied by the dynamic load factor (DLF), was used to determine the maximum g-level on the cask during a 4-ft end drop accident onto the heavily reinforced FFTF Reactor Service Building`s concrete surface. For the analysis, this surface was assumed to be unyielding and the cask absorbed all the drop energy. This conservative assumption simplified the modeling used to qualify the cask`s structural integrity for this accident condition.
1996-06-01
Energy Technology Data Exchange (ETDEWEB)
A laboratory differential simulation method is used for the design of carbonization columns at coal-tar processing in which phenols are regenerated from phenolate solution by carbon dioxide absorption. The design method is based on integration of local absorption rates of carbon dioxide along the column. The local absorption rates into industrial phenolate mixture are measured in a laboratory model contactor for various compositions of the gas and liquid phases under the conditions that ensure the absorption rates in the laboratory absorber simulate the local rates in the industrial column. On the bases of the calculations, two-step carbonization columns were designed for 30000 t/year of the phenolate solution treatment by carbon dioxide. The absorption proceeds at higher pressure of 500 kPa and temperatures from 50 to 65 C, pure carbon dioxide is used and toluene is added. These conditions have the following favourable effects: (I) significant ...
2009-01-15
International Nuclear Information System (INIS)
It is very well known that the CANDU reactor has positive Coolant Void Reactivity (CVR), which is most important criticisms about CANDU. The most recent innovations based on using a thin absorbent Hafnium shell in the central bundle element were successfully been applied to the Advanced CANDU Reactor (ACR) project. The paper's objective is to analyze elementary lattice cell effects in applying such methods to reduce the CVR. Three basic fuel designs in their corresponding geometries were chosen to be compared: the ACR-1000TM, the RU-43 (developed in INR Pitesti) and the standard CANDU fuel. The bundle geometry influence on void effect was also evaluated. The WIMS calculations proved the Hafnium absorber suitability (in the latest 'shell design') to achieve the negative CVR target with great accuracy for the ACR-1000 fuel bundle design than for the other two projects. (authors)
2009-05-27
PROBABILISTIC SAFETY ASSESSMENT OF OPERATIONAL ACCIDENTS AT THE WASTE ISOLATION PILOT PLANT
Energy Technology Data Exchange (ETDEWEB)
This report presents a probabilistic safety assessment of radioactive doses as consequences from accident scenarios to complement the deterministic assessment presented in the Waste Isolation Pilot Plant (WIPP) Safety Analysis Report (SAR). The International Council of Radiation Protection (ICRP) recommends both assessments be conducted to ensure that ''an adequate level of safety has been achieved and that no major contributors to risk are overlooked'' (ICRP 1993). To that end, the probabilistic assessment for the WIPP accident scenarios addresses the wide range of assumptions, e.g. the range of values representing the radioactive source of an accident, that could possibly have been overlooked by the SAR. Routine releases of radionuclides from the WIPP repository to the environment during the waste emplacement operations are expected to be essentially zero. In contrast, potential accidental releases from postulated accident ...
2000-09-01
Energy Technology Data Exchange (ETDEWEB)
In the case of total skin electron therapy without the beam guide, the electron beam is scattered just outside the gantry exit, dose uniformity in the field is broken, and dose is spread outside the light field. The aims of this study were to measure the mean energy of the off-axis incident electron beam without the beam guide and to establish a reference for the clinical situation. For the measurement, a 4 MeV electron beam was selected among several energies from the linear accelerator. A scintillating fiber beam energy monitor measured the mean energy of the incident electron beam. This energy monitor is a small, light-weight piece of equipment composed of a wedge absorber, scintillation fiber, and photodiode. We found the relationship between electron energy and the indicated value of the energy monitor by means of the estimation of correction factors for five different kinds of electron energy. The preferable linear ...
2002-06-01
International Nuclear Information System (INIS)
Processing of food with ionizing radiation is a method suitable to enhance shelf-life and hygienic quality. Up to a dose of 10 kGy the method is considered wholesome. In many countries the practical use of food irradiation is increasing, however, in the Federal Republic of Germany the process is strictly forbidden. Applications and methods for radiation processing of food are compiled, limits and prospects are explained, and advantages and disadvantages are compared with traditional methods. Identification of irradiated foods and dosimetry and process control for radiation processing of food are areas where further research is needed. Continuous processing of particulate foods in bulk is an application where electron accelerators might be profitable. Beam parameters and velocity distribution of food particles in the treatment area can be matched for an effective result. Thus, dose distribution can be adjusted for homogeneous treatment and at ...
Energy Technology Data Exchange (ETDEWEB)
The effect of a complexon therapy scheme including early (in 1 h) administration of Na/sub 3/Ca DTPA and subsequent administration of Na/sub 3/Zn DTPA or Na/sub 3/Ca DTPA at a dose of 25 ..mu..Cimol/kg/day by three 2-week courses (5 times a week) with 2-week interruptions was studied in experiments on 541 male rats after intraperitoneal administration of /sup 239/Pu citrate complex (95 kBq/kg). The treatment resulted in a 3-fold lessening of the content of /sup 239/Pu and absorbed doses in the skeleton, a significant prolongation of the mean survival time (MST) from 452 to 593 days (Na/sub 3/Zn DTPA) and 643 days (Na/sub 3/Ca DTPA), and in a decrease of the osteosarcoma incidence from 76.4 to 32.6-41.2%. The ratio of osteosarcomas per 1 Gy retained in rats (0.076-0.083 %) did not differ from that in untreated animals.
1985-02-01
Is uniform target dose possible in IMRT plans in the head and neck?
International Nuclear Information System (INIS)
Purpose: Various published reports involving intensity-modulated radiotherapy (IMRT) plans developed using automated optimization (inverse planning) have demonstrated highly conformal plans. These reported conformal IMRT plans involve significant target dose inhomogeneity, including both overdosage and underdosage within the target volume. In this study, we demonstrate the development of optimized beamlet IMRT plans that satisfy rigorous dose homogeneity requirements for all target volumes (e.g., #+-#5%), while also sparing the parotids and other normal structures. Methods and Materials: The treatment plans of 15 patients with oropharyngeal cancer who were previously treated with forward-planned multisegmental IMRT were planned again using an automated optimization system developed in-house. The optimization system allows for variable sized beamlets computed using a three-dimensional convolution/superposition dose ...
2002-04-01
International Nuclear Information System (INIS)
Brachytherapy refers to short distance treatment of cancer with radiation from small, encapsulated radionuclide sources. This type of treatment is given by placing sources directly into or near the volume to be treated. The dose is then delivered continuously, either over a short period of time (temporary implants) or over the lifetime of the source to a complete decay (permanent implants). This technique is extensively used in the treatments of gynecological, breast, prostate, head and neck, and other soft tissue cancers. The clinical outcomes of this treatment depend on accurate dosimetry and dose delivery. The patient is generally considered to be water equivalent. So the treatment planning system software generally is based on measured or calculated dose distributions in homogenous water medium. In real situation, the treatment volume is not homogenous water medium, but it is a heterogeneous medium ...
2009-04-01
International Nuclear Information System (INIS)
This work describes an experimental verification of the two-photon dose calculation engines available on the Helax-TMS (version 6.1) commercial radiotherapy treatment planning system. The performance of the pencil beam convolution and the collapsed cone superposition algorithms was examined for 4, 6, 15 MV beams, under a range of clinically relevant irradiation geometries. Comparisons against measurements were carried out in terms of absolute dose, thus assessment of the accuracy of monitor unit (MU) calculations was also carried out. Results show that both algorithms agree with measurement to acceptable tolerance levels in most cases in homogeneous water-equivalent media irradiated under full scatter conditions. The collapsed cone algorithm slightly overestimates the penumbra width and this is mainly due to discretization effects of the fluence matrix. The accuracy of this algorithm strongly depends on ...
2003-09-07
International Nuclear Information System (INIS)
Current methods to calculate dose distributions with organ motion can be broadly classified as 'dose convolution' and 'fluence convolution' methods. In the former, a static dose distribution is convolved with the probability distribution function (PDF) that characterizes the motion. However, artifacts are produced near the surface and around inhomogeneities because the method assumes shift invariance. Fluence convolution avoids these artifacts by convolving the PDF with the incident fluence instead of the patient dose. In this paper we present an alternative method that improves the accuracy, generality as well as the speed of dose calculation with organ motion. The algorithm starts by sampling an isocenter point from a parametrically defined space curve corresponding to the patient-specific motion trajectory. Then a photon is sampled in the ...
2005-04-01
Effective dose estimation in whole-body multislice CT in paediatric trauma patients
Energy Technology Data Exchange (ETDEWEB)
The number of multislice CT (MSCT) scans performed in polytraumatized children has increased rapidly. There is growing concern regarding the radiation dose in MSCT and its long-term consequences, especially in children. To determine the effective dose to polytraumatized children who undergo whole-body MSCT. A total of 51 traumatized children aged 0-16 years underwent a polytrauma protocol CT scan between November 2004 and August 2006 at our institution. The effective dose was calculated retrospectively by a computer program (CT-Expo 1.5, Hannover, Germany). The mean effective dose was 20.8 mSv (range 8.6-48.9 mSv, SD{+-}7.9 mSv). There was no statistically significant difference in the effective dose between male and female patients. Whole-body MSCT is a superior diagnostic tool in polytraumatized children with 20.8 mSv per patient being a justified mean ...
2009-03-15
Cytogenetic effects of protracted gamma exposures from conception of male mice
Energy Technology Data Exchange (ETDEWEB)
In order to gain an overall picture of the genetic effects of an increased level of background radiation it is necessary to study the results of protracted exposures to embryonic and immature germ-cell stages as well as to stages found in the mature organism. For this purpose, litters produced by female mice, kept in a 10 or 20 rad/day /sup 60/Co ..gamma..-irradiation field, were kept in the same fields from conception until about 60 days later, having absorbed doses of 526 and 1078 rad respectively. Tests on exposed female offspring showed them to be sterile. Eight weeks after removal from the gamma field, mean testis masses of males in the 20 rad/day series were only half normal but those receiving 10 rad/day were little affected. Frequencies of translocations in spermatocytes at diakinesis/metaphase I were only slightly increased in the exposed series, differences not being significant. Estimated rates of translocation induction were around ...
1982-01-01
Low dose effects - is the fear more dangerous than the radiation?
Energy Technology Data Exchange (ETDEWEB)
The use of hypothesis which assumes a dose / harmful effect relationship without a limit allows the calculation of risks attributable to doses too small to produce detectable, harmful biological effects. The daughter product of this hypothesis is ALARA concept which requires that the dose received is kept as low as reasonably achievable. This concept of prudent avoidance is generally accepted by international radiation protection organisations and universally applied by radiation health professionals. The acceptance of a hypothesis which assumes that a single nuclear event can cause carcinogenesis, has generated levels of anxiety which may have resulted in significant detriment to those possibly exposed to ionising radiation. The anxiety generated may have caused more detriment and a higher death rate than the worst case ` theoretical` value calculated using the Linear or Quadratic ...
1996-01-01
Energy Technology Data Exchange (ETDEWEB)
This report summarises work done on the SUCON Project during 1996-1999 (European Commission Contract No. FI4C-CT95-0001). The project has focused on three major objectives: 1) An assessment of the radiological consequences of the contamination of the South Urals and the Ob river system from the production of plutonium at 'Mayak', 2) The development of models to calculate doses to individuals and populations in the South Urals using environmental data, and 3) The intercomparison, harmonisation and standardisation of techniques used in dose reconstruction and specification of good practice in particular with regard to remedial measures. (au)
2000-12-01
International Nuclear Information System (INIS)
Objective: To estimate exposure dose of personnel around patients by Monte Carlo method and integration method. Methods: Exposures were estimated by a Monte Carlo practical program with Visual Basic 6.0 and integration method using 'pen-and-paper'. Results: Exposures for rectangle and ellipse sources were calculated. The difference between different methods for various sources were 0.88% and 0.61%, respectively. Conclusion: The results estimated by Monte Carlo method are close to those of integration method. It is illustrated that doses of other people estimated by Monte Carlo method are significant
2001-08-01
Estimated values of the genetic and somatic radiation exposure of the Bulgarian population in 1976
International Nuclear Information System (INIS)
The genetically and leukemia-significant doses (GSD and LSD) were calculated from the average gonad and bone marrow doses caused by the most frequently applied radiopharmaceuticals in Bulgaria in 1976. Because of the lack of information about the age groups of the patients examined assumptions have been made which led to estimated values of 0.97 mrad for GSD and 2.0 mrad for LSD which must be considered as the upper limit of the real GSD and LSD. The influence of the different radiopharmaceuticals on the average radiation exposure of the population is discussed. (author).
1976-01-01
CyberKnife SRS: new technologies that enhance the treatment of cancer
International Nuclear Information System (INIS)
The CyberKnife Robotic Radiosurgery System (Accuracy Incorporated, Sunnyvale, CA, USA) is used worldwide to treat tumors and neurological disorders anywhere in the body with sub-millimetre beam delivery accuracy. Accuracy has developed a number of new technologies in recent years to enhance the treatment of cancer patients. Such new technologies include a fast Monte Carlo Dose Calculation algorithm, Sequential Optimization dose planning, the IrisTM Variable Aperture Collimator, an 800 MU/min Linear Accelerator, and Optimized Path Traversal. These technologies enable physicists and physicians to plan treatments quickly and easily and deliver them with unrivalled accuracy and precision
2008-11-26
Conformal radiation therapy: technical requirements and clinical applications
International Nuclear Information System (INIS)
Conformal radiation therapy represents a considerable and attractive challenge in oncology. Its aim is mainly to improve local control by increasing the dose with an acceptable rate of complications. This work overviews the world literature on this subject. The technical and theoretical requirements are highlighted. These requirements include a precise definition of the target volume by digital imaging (essentially CT scan), but also clear view of the target volume and the organs at risk, a specific collimation of the beam, 3-D dose calculations, optimization procedures, and a rigid immobilization of the patient with verification of his position. Moreover, the clinical applications of conformal radiation therapy are reviewed and discussed. (authors). 80 refs., 1 tab.
1995-01-01
Assessment of tritium in the Savannah River Site environment
Energy Technology Data Exchange (ETDEWEB)
This report is the first revision to a series of reports on radionuclides inn the SRS environment. Tritium was chosen as the first radionuclide in the series because the calculations used to assess the dose to the offsite population from SRS releases indicate that the dose due to tritium, through of small consequence, is one of the most important the radionuclides. This was recognized early in the site operation, and extensive measurements of tritium in the atmosphere, surface water, and ground water exist due to the effort of the Environmental Monitoring Section. In addition, research into the transport and fate of tritium in the environment has been supported at the SRS by both the local Department of Energy (DOE) Office and DOE`s Office of Health and Environmental Research.
1993-10-01
Analyses of superficial and depth doses in intraoral radiology
Energy Technology Data Exchange (ETDEWEB)
In this work dosimetric analysis using thermoluminescence technique to study the beams characteristics of x-rays employed in dental radiology has been carried out. The obtained results with CaSO{sub 4}:Dy thermoluminescent dosimeters (TLD) were compared to the doses obtained with parallel-plates ionization chamber. Dosimetric evaluations were also done using radiographic films of large dimensions. The x-rays equipments analyzed were installed in the radiological services of Odontology Department of Sergipe Federal University (U.F.S.). Depending on the anatomical region to be examined the proper exposure time was select, for a fix voltage of 70 kV. The results with TLD and ionization chamber have been determined to female and male individuals. The intraoral regions analysed were the peri apical of the incisors, molar and pre-molar teeth and the occlusive region. These regions were simulated using acrylic plates absorbers installed on the film ...
2006-07-01
International Nuclear Information System (INIS)
Purpose: In this paper, we present an alternative to the originally proposed technique for the delivery of spatially fractionated radiation therapy (GRID) using multi-leaf collimator (MLC) shaped fields. We employ the MLC to deliver various pattern GRID treatments to large solid tumors and dosimetrically characterize the GRID fields. Methods and materials: The GRID fields were created with different open to blocked area ratios and with variable separation between the openings using a MLC. GRID designs were introduced into the Pinnacle"3 treatment planning system, and the dose was calculated in a water phantom. Ionization chamber and film measurements using both Kodak EDR2 and Gafchromic EBT film were performed in a SolidWater phantom to determine the relative output of each GRID design as well as its spatial dosimetric characteristics. Results: Agreement within 5.0% was observed between the Pinnacle"3 predicted dose ...
2009-10-01
Energy Technology Data Exchange (ETDEWEB)
To assess the internal dose by {sup 3}H and {sup 14}C in total diet of inhabitants near Wolsung nuclear power plants, TFWT, OBT and {sup 14}C concentration in total diet was analyzed for collection region and time. TFWT, OBT and {sup 14}C concentrations were in the range of 3.19-42.2 Bq/L, 1.00-39.4 Bq/L, and 0.230-0.856 Bq/gC, respectively. The calculated annual effective dose with TFWT, OBT and {sup 14}C is 6.10 x 10{sup -5} mSv/y, 3.71 x 10{sup -5} mSv/y and 7.08 x 10{sup -3} mSv/y, respectively. And then annual internal dose with total diet for inhabitants near Wolsung NPPs is about 7.18 x 10{sup -3} mSv/y, which is about 0.72% of annual effective dose limit 1 mSv/y.
2003-03-15
Energy Technology Data Exchange (ETDEWEB)
To assess the internal dose by 3 H and 14 C in total diet of inhabitants near Wolsung Nuclear Power Plants, TFWT, OBT and 14 C concentration in total diet was analyzed for collection region and time. TFWT, OBT and 14 C concentrations were in the range of 3.19-42.2 Bq/L , 1.00-39.4 Bq/L, and 0.230-0.856 Bq/gC, respectively. The calculated annual effective dose with TFWT, OBT and 14 C is 6.1010 -5 mSv/y, 3.7110 -5 mSv/y and 7.0810 -3 mSv/y, respectively. And then annual internal dose with total diet for inhabitants near Wolsung NPPs is about 7.1810 -3 mSv/y, which is about 0.72% of annual effective dose limit 1 mSv/y.
2002-07-01
International Nuclear Information System (INIS)
To assess the internal dose by "3H and "1"4C in total diet of inhabitants near Wolsung nuclear power plants, TFWT, OBT and "1"4C concentration in total diet was analyzed for collection region and time. TFWT, OBT and "1"4C concentrations were in the range of 3.19-42.2 Bq/L, 1.00-39.4 Bq/L, and 0.230-0.856 Bq/gC, respectively. The calculated annual effective dose with TFWT, OBT and "1"4C is 6.10 x 10"-"5 mSv/y, 3.71 x 10"-"5 mSv/y and 7.08 x 10"-"3 mSv/y, respectively. And then annual internal dose with total diet for inhabitants near Wolsung NPPs is about 7.18 x 10"-"3 mSv/y, which is about 0.72% of annual effective dose limit 1 mSv/y.
2003-03-01
International Nuclear Information System (INIS)
To assess the internal dose by 3 H and 14 C in total diet of inhabitants near Wolsung Nuclear Power Plants, TFWT, OBT and 14 C concentration in total diet was analyzed for collection region and time. TFWT, OBT and 14 C concentrations were in the range of 3.19-42.2 Bq/L , 1.00-39.4 Bq/L, and 0.230-0.856 Bq/gC, respectively. The calculated annual effective dose with TFWT, OBT and 14 C is 6.1010 -5 mSv/y, 3.7110 -5 mSv/y and 7.0810 -3 mSv/y, respectively. And then annual internal dose with total diet for inhabitants near Wolsung NPPs is about 7.1810 -3 mSv/y, which is about 0.72% of annual effective dose limit 1 mSv/y.
2002-10-20
Assessment of dose-time-effect surfaces for somatic late effects after low dose irradiation
International Nuclear Information System (INIS)
Awaiting new data from RERF, an attempt was made to estimate the somatic risks of low doses of radiation for members of the German public. The new estimate follows closely the approach used in deriving the values published in the NIH Radioepidemiological Tables. The lifetime risk factors thus calculated are significantly larger than the estimates presented in ICRP Report 26 and are consistent with estimates recently made in the ongoing reactor safety study of NUREG. The increase in lifetime risks is mainly due to the introduction of a new time projection model which appears to be more consistent with the epidemiological data for many late effect end points than the constant absolute risk model previously employed. Results from a study in which epidemiological data were stochastically simulated with a computer indicate that the shapes of actual dose effect curves might be significantly more influenced by pure chance than by ...
1988-04-01
Energy Technology Data Exchange (ETDEWEB)
IMRT with inverse planning allows simultaneous integrated boost strategies that exploit the heterogeneous dose distribution within the planning target volumes (PTVs). In this scenario, the location of cold spots within the target becomes a crucial issue and has to be related to the distribution of the clonogenic cell density (CCD). The main aim of this work is to provide the means to calculate the optimal prescription dose in a relative inhomogeneous dose distribution. To achieve this, the prescription dose has to be assigned to obtain the same tumor control probability (TCP) as the ideal homogeneous distribution, taking into account different CCDs in different PTVs (i.e. visible and subclinical regions). An adapted formulation of the linear-quadratic model, within the F-factor formalism, has been derived to preserve a chosen TCP value for the whole target volume. The F-factor has ...
2008-10-07
As a result of the large limestone deposits available in Poland, the low cost of reagent acquisition for the largescale technological use and relatively well-documented processes of flue gas desulfurization (FGD) technologies based on limestone sorbent slurry, wet scrubbing desulfurization is a method of choice in Poland for flue gas treatment in energy production facilities, including power plants and industrial systems. The efficiency of FGD using the above method depends on several technological and kinetic parameters, particularly on the pH value of the sorbent (i.e., ground limestone suspended in water). Consequently, many studies in Poland and abroad address the impact of various parameters on the pH value of the sorbent suspension, such as the average diameter of sorbent particles (related to the limestone pulverization degree), sorbent quality (in terms of pure calcium carbonate [CaCO3] content of the sorbent material), stoichiometric surfeit of CaCO3 in relation to sulfur ...
2010-08-01
A compensating method of an imaging plate response to clinical proton beams
Energy Technology Data Exchange (ETDEWEB)
For charged particle irradiations, the response of an imaging plate (IP) changes around the Bragg peak. Therefore, an appropriate compensation is necessary for the evaluation of dose distribution formed by charged particles such as protons. In this paper, the response of IPs to clinical proton beams is investigated. An experimentally-obtained depth-dose distribution (an ordinary Bragg curve) by a silicon semiconductor detector (SSD) is employed to evaluate the compensation factors as a function of proton penetrating depth, i.e. residual range. A typical dose distribution in a water phantom formed by an L-shaped bolus is measured by IPs and corrected by using the information of those compensation factors; the residual proton range is successfully calculated by the pencil beam algorithm at an arbitrary point. The results show a good agreement with the measurements by the SSD within the rms error of 3.0%.
2002-04-01
Towards an objective evaluation of tolerances for beam modeling in a treatment planning system
International Nuclear Information System (INIS)
The performance of a convolution/superposition based treatment planning system depends on the ability of the dose calculation algorithm to accurately account for physical interactions taking place in the tissue, key components of the linac head and on the accuracy of the photon beam model. Generally the user has little or no control over the performance of the dose calculation algorithm but is responsible for the accuracy of the beam model within the constraints imposed by the system. This study explores the dosimetric impact of limitations in photon beam modeling accuracy on complex 3D clinical treatment plans. A total of 70 photon beam models was created in the Pinnacle(TM) treatment planning system. Two of the models served as references for 6 MV and 15 MV beams, while the rest were created by perturbing the reference models in order to produce specific deviations in specific regions of the ...
2007-09-21
Monte Carlo simulation and dosimetric verification of radiotherapy beam modifiers
International Nuclear Information System (INIS)
Monte Carlo simulation of beam modifiers such as physical wedges and compensating filters has been performed with a rectilinear voxel geometry module. A modified version of the EGS4/DOSXYZ code has been developed for this purpose. The new implementations have been validated against the BEAM Monte Carlo code using its standard component modules (CMs) in several geometrical conditions. No significant disagreements were found within the statistical errors of 0.5% for photons and 2% for electrons. The clinical applicability and flexibility of the new version of the code has been assessed through an extensive verification versus dosimetric data. Both Varian multi-leaf collimator (MLC) wedges and standard wedges have been simulated and compared against experiments for 6 MV photon beams and different field sizes. Good agreement was found between calculated and measured depth doses and lateral dose profiles along both wedged and ...
2001-11-01
Preliminary activation calculations for the PDX tokamak
Energy Technology Data Exchange (ETDEWEB)
Activation dose rates have been computed for the Poloidal Divertor Experiment Tokamak at the Princeton Plasma Physics Laboratory. Dose rates were computed in one-dimensional (cylindrical) geometry using the ANISN S/sub n/ transport theory code and the DKR radioactivity code. The EPR (DLC37F) 121-group coupled neutron-gamma cross section library was used with ANISN. For DKR, the 46-group neutron library of DCDLIB was employed. Dose rates were calculated for 1 minute, 1 hour, 6 hours, 24 hours, 1 week, and 1 month following a single pulse yielding 10/sup 15/ neutrons and for 2 hypothetical pulsing sequences. First, it was assumed that 10 pulses were conducted each day (1 hour apart) for 5 days. Second, it was assumed that 100 pulses were conducted each day (6 minutes apart) for 5 days. It was found that /sup 56/Mn and /sup 64/Cu are the main contributors to the dose at short time ...
1980-10-01
International Nuclear Information System (INIS)
The advent of multislice spiral CT (MSCT) technique has led to new aspects of dose reduction, especially for the dedicated use of MSCT in children. Optimizing pediatric MSCT protocols according to the clinical problem allows reduction of radiation exposure to a minimum without loss of diagnostic quality. The different parameters that influence the degree of dose reduction, like tube current-time product (mAs), tube voltage (kV), collimation and pitch, are discussed in context with previously published data and our own experience in nearly 200 pediatric CT examinations. In our department, the effective mAs is calculated for a pediatric chest MSCT by multiplication of the body weight in kilogram with a factor of 1 to 1.5 and for a pediatric abdominal MSCT by multiplication with a factor of 2 to 2.5. To calculate the equivalent effective dose for a contrast media-enhanced 80 kV ...
2004-07-01
International Nuclear Information System (INIS)
The aim of the safety calculation is to quantify through numerical modelling the radiological impact (molar flow, human dose) of a potential repository for radioactive waste on the Meuse/Haute Marne site at Bure. A selection process is underway for safety scenarios and their phenomenological and numerical conceptual models upstream from the safety calculation. This involves defining and quantifying the geometric and dimensional representations of the repository for each scenario plus the physical, mathematical and numerical models that reflect its behaviour and the uncertainties associated with all the parameters required to quantify the impact. A summary will be given of these various aspects. The numerical simulations are then performed on the Alliances platform which integrates the various computer codes required for the physical representation of the system. (authors)
2005-03-14
International Nuclear Information System (INIS)
In this work an analysis of the influence of the choice of the algorithm or planning system, on the calculus of the same treatment plan is introduced. For this purpose specific software has been developed for comparing plans of a series of IMRT cases of prostate and head and neck cancer calculated using the convolution, superposition and fast superposition algorithms implemented in the XiO 4.40 planning system (CMS). It has also been used for the comparison of the same treatment plan for lung pathology calculated in XiO with the mentioned algorithms, and calculated in the Plan 4.1 planning system (Brainlab) using its pencil beam algorithm. Differences in dose among the treatment plans have been quantified using a set of metrics. The recommendation for the dosimetrist of a careful choice of the algorithm has been numerically confirmed. (Author).
International Nuclear Information System (INIS)
A major deficiency of current photon calculation methods that are based on the concept of primary and scatter separation is their inability to handle the condition of electronic disequilibrium. This deficiency is examined and it is shown that the limitation is not inherent in the algorithms themselves but is, at least in part, in the data which the algorithms use. A new concept of primary and scatter separation is developed to cover the condition of electronic disequilibrium. This new concept requires little change to the existing algorithms and only additional data are required, which are generated using Monte Carlo calculation methods. The new concept is tested using programs in the Theratronics Theraplan treatment-planning system, and two calculation examples illustrate the ability to model electron transport and also the improvement over the existing algorithms. Close analogy of the extended concept with the ...
International Nuclear Information System (INIS)
Operations at the Savannah River Site (SRS) result in releases of small amounts of radioactive materials to the atmosphere and to the Savannah River. For regulatory compliance purposes, potential offsite radiological doses are estimated annually using computer models that follow U.S. Nuclear Regulatory Commission (NRC) Regulatory Guides. Within the regulatory guides, default values are provided for many of the dose model parameters but the use of site-specific values by the applicant is encouraged. A detailed survey of land and water use parameters was conducted in 1991 and is being updated here. These parameters include local characteristics of meat, milk and vegetable production; river recreational activities; and meat, milk and vegetable consumption rates as well as other human usage parameters required in the SRS dosimetry models. In addition, the preferred elemental bioaccumulation factors and transfer factors to be used in human health ...
British Library Electronic Table of Contents (United Kingdom)
Interactions between cationic dye-cationic surfactant and anionic dye-cationic surfactant systems were investigated in aqueous solutions using spectrophotometric method at 288.15, 298.15, 308.15 and 318.15K. C.I. Basic Red 9 (BR9) and C.I. Acid Blue 25 (AB25) were used as cationic and anionic dyes, respectively, and hexadecyltrimethylammonium bromide (HDTMABr) was selected as cationic surfactant in this study. Although there was an interaction between the AB25 and the HDTMABr molecules, an interaction between the BR9 and HDTMABr did not occur due to the electrostatic repulsion forces. Binding constants and partition coefficients between the micellar and the bulk water phases for the AB25-HDTMABr system were calculated from the changes in absorbance values and the critical micelle concentra...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
An analysis is presented for the effects of chemical reaction and thermal radiation on hydromagnetic free convection heat and mass transfer for a micropolar fluid via a porous medium bounded by a semi-infinite vertical porous plate in the presence of heat generation. The plate moves with a constant velocity in the longitudinal direction and the free stream velocity follows an exponentially small perturbation law. A uniform magnetic field acts perpendicularly to the porous surface in which absorbs the micropolar fluid with a suction velocity varying with time. Analytical expressions are computed numerically. Numerical calculations are carried out the purpose of the discussion of the results which are shown on graphs and the effects of the various dimensionless parameters entering into the p...
2009-01-01
Design of the electromagnetic actuator for vibration control of a flexible rotor
Energy Technology Data Exchange (ETDEWEB)
In order to suppress resonance vibrations of a rotor-shaft of rotating machinery, a rotor-shaft system elastically supported by ball bearings which are installed in electromagnetic actuators are proposed and the design method of some compensatory circuits in the controller to control the electromagnetic actuators in the system are explained. These actuators are controlled by the analog PID (proportional, integral, and derivative) controller. The compensation for nonlinearity of electromagnetic force, the negative stiffness of electromagnet, and the time lag of the coil current are discussed and the effective control circuits are proposed. The rotor-shaft system is replaced by the equivalent two-degree-of-freedom system and both impulse and frequency responses are numerically simulated for several parameters of PD-controller gain. By applying the principle of dynamic absorbers, optimum parameters are calculated. The gains of the control circuit ...
1994-12-21
British Library Electronic Table of Contents (United Kingdom)
Derivative spectrophotometry and bivariate calibration algorithm were used for study of run of photooxidation of levomepromazine hydrochloride (LV). The actual concentrations of LV and its main degradation product levomepromazine sulphoxide (LV-SO) were calculated using data provided by applied methods. The direct reading of absorbance values at 302nm and 334nm were employed for quantification of LV and LV-SO, respectively, in the case of bivariate method. The derivative spectrophotometric method is based on transformation of zero-order spectra into first derivative. The values of first derivative at 334nm were used for quantification of LV while at 278nm for assay of LV-SO. The obtained quantitative data were applied for investigation of kinetics of photodegradation of LV.
2008-01-01
International Nuclear Information System (INIS)
An ytterbium-169 high dose rate brachytherapy source, distinguished by an intensity-weighted average photon energy of 92.7 keV and a 32.015#+-#0.009 day half-life, is characterized in terms of the updated AAPM Task Group Report No. 43 specifications using the MCNP5 Monte Carlo computer code. In accordance with these specifications, the investigation included Monte Carlo simulations both in water and air with the in-air photon spectrum filtered to remove low-energy photons below 10 keV. TG-43 dosimetric data including S_K, D(r,#theta#), #LAMBDA#, g_L(r), F(r,#theta#), #phi#_a_n(r), and #phi#_a_n were calculated and statistical uncertainties in these parameters were derived and calculated in the appendix.
2006-01-01
Rapid administration of stable iodine is essential for the saturation and subsequent protection of the thyroid gland against the potential harm caused by radioiodines. This paper proposes the Dutch risk analysis that uses an atmospheric dispersion model to calculate the size of the zones around nuclear power plants where radiological thyroid doses for children might be sufficiently high to warrant iodine administration. Dose calculations for possible releases from the nuclear power plants of Borssele (The Netherlands), Doel (Belgium) and Emsland (Germany) are based on two scenarios in combination with a 1-y set of authentic, high-resolution meteorological data. The dimensions of the circular zones were defined for each nuclear power plant. In these zones, with a radius up to 50 km, distribution of stable iodine tablets is advised. PMID:20332130
2010-03-23
British Library Electronic Table of Contents (United Kingdom)
Rapid administration of stable iodine is essential for the saturation and subsequent protection of the thyroid gland against the potential harm caused by radioiodines. This paper proposes the Dutch risk analysis that uses an atmospheric dispersion model to calculate the size of the zones around nuclear power plants where radiological thyroid doses for children might be sufficiently high to warrant iodine administration. Dose calculations for possible releases from the nuclear power plants of Borssele (The Netherlands), Doel (Belgium) and Emsland (Germany) are based on two scenarios in combination with a 1-y set of authentic, high-resolution meteorological data. The dimensions of the circular zones were defined for each nuclear power plant. In these zones, with a radius up to 50 km, distrib...
2010-01-01
British Library Electronic Table of Contents (United Kingdom)
Purpose: In this paper, we present an alternative to the originally proposed technique for the delivery of spatially fractionated radiation therapy (GRID) using multi-leaf collimator (MLC) shaped fields. We employ the MLC to deliver various pattern GRID treatments to large solid tumors and dosimetrically characterize the GRID fields. Methods and materials: The GRID fields were created with different open to blocked area ratios and with variable separation between the openings using a MLC. GRID designs were introduced into the Pinnacle3 treatment planning system, and the dose was calculated in a water phantom. Ionization chamber and film measurements using both Kodak EDR2 and Gafchromic EBT film were performed in a SolidWater phantom to determine the relative output of each GRID design as w...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 MeV is desirable. Key words: neutron--gamma ...
1983-01-01
International Nuclear Information System (INIS)
Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 MeV is desirable. Key words: neutron--gamma ...
7871-01-01
Disposal of old heads for Daya Bay NPP
International Nuclear Information System (INIS)
The paper introduces the disposal procedures of the old reactor pressure vessel head. Reactor pressure vessel (RPV) heads were replaced successfully in Daya Bay Nuclear Power Plant. The on-site treatment and disposal of replaced heads was thereafter implemented. This is the first time in China for large size radioactive article disposal. To guarantee the safety of old head treatment, issues of radiation protection have to be taken into account. Dose rate distribution of the old head surface and radioactivity were initially calculated according to the operation history and the neutron flux rate of the reactor. Shielding calculation and package design was thereafter worked out based on the data obtained from the old head, e.g. neutron flux, sorts of nuclides, radioactivity and dose rates. Shielding package was afterwards manufactured in special factories and transported to Daya Bay NPP site by truck and ...
A deterministic partial differential equation model for dose calculation in electron radiotherapy
International Nuclear Information System (INIS)
High-energy ionizing radiation is a prominent modality for the treatment of many cancers. The approaches to electron dose calculation can be categorized into semi-empirical models (e.g. Fermi-Eyges, convolution-superposition) and probabilistic methods (e.g. Monte Carlo). A third approach to dose calculation has only recently attracted attention in the medical physics community. This approach is based on the deterministic kinetic equations of radiative transfer. We derive a macroscopic partial differential equation model for electron transport in tissue. This model involves an angular closure in the phase space. It is exact for the free streaming and the isotropic regime. We solve it numerically by a newly developed HLLC scheme based on Berthon et al (2007 J. Sci. Comput. 31 347-89) that exactly preserves the key properties of the analytical solution on the discrete level. We discuss several test cases ...
2010-07-07
International Nuclear Information System (INIS)
Background and purpose: the recent RTOG guidelines for future clinical developments in gynecologic malignancies included the investigation of dose escalation in the paraaortic (PO) region which is, however, very difficult to target due to the presence of critical organs such as kidneys, liver, spinal cord, and digestive structures. The aim of this study was to investigate intensity-modulated radiotherapy's (IMRT) possibilities of either increasing, in a safe way, the dose to 50-60 Gy in case of macroscopic disease or decreasing the dose to organs at risk (OR) when treatment is given in an adjuvant setting. Material and methods: the dosimetric charts of 14 patients irradiated to the PO region at the department of radiation oncology, university hospital of Liege, Belgium, in 2000 were analyzed in order to compare six-field conformal external-beam radio-therapy (CEBR) and five-beam IMRT approaches. Both CEBR and IMRT ...
2005-03-01
International Nuclear Information System (INIS)
In the convolution/superposition algorithm, the energy spectrum should be modified to make the reconstructed dose distribution consistent with the measured dose distribution. The energy spectrum, which gives the best agreement, is not determined uniquely depending on the reconstruction procedure. In this report, the effects of the characteristics of the energy spectrum on the calculation accuracy are evaluated by comparing the percentage depth dose (PDD) and beam profiles for the reference energy spectrum with those calculated for the modified spectrum in order to optimize the energy spectrum modification procedure when 4 and 10 MV X-ray beams are used. Decreasing the number of energy bins brought a larger decrease rate in the computation accuracy than a decrease rate in computation time. Further, the decrease of the number of energy bins led to a change of the energy spectrum. The ...
2003-06-01
Physics and quality assurance of low dose rate brachytherapy
International Nuclear Information System (INIS)
Purpose: The purpose of this course is to review the physical principles underlying design, clinical application and execution of interstitial and intracavitary implants in the classical low dose-rate (LDR) range. This year, the course will focus on quality assurance of sources, applicators and treatment planning software. In addition, development of procedures and QA checks designed optimize treatment delivery accuracy and patient safety during each individual procedure will be reviewed. The level of presentation will be designed to accommodate both physicists and physicians. Implementation of recently published AAPM Task Group reports (no. 40, 'Comprehensive Quality Assurance' and No. 43, 'Dosimetry of Interstitial Brachytherapy Sources') will be reviewed. Outline: (A) General Principles (1) QA endpoints: temporal accuracy, positional accuracy, dose delivery accuracy, and safety of the patient, personnel, and the institution (2) QA procedure ...
An iterative filtered backprojection inverse treatment planning algorithm for tomotherapy
International Nuclear Information System (INIS)
Purpose: An inverse treatment planning algorithm for tomotherapy is described. Methods and Materials: The algorithm iteratively computes a set of nonnegative beam intensity profiles that minimizes the least-squares residual dose defined in the target and selected normal tissue regions of interest. At each iteration the residual dose distribution is transformed into a set of residual beam profiles using an inversion method derived from filtered backprojection image reconstruction theory. These 'residual' profiles are used to correct the current beam profile estimates resulting in new profile estimates. Adaptive filtering is incorporated into the inversion model so that the gross structure of the dose distribution is optimized during initial iterations of the algorithm, and the fine structure corresponding to edges is obtained at later iterations. A three dimensional, kernel based, convolution/superposition ...
1995-07-15
International Nuclear Information System (INIS)
Using Monte Carlo simulation and the convolution/superposition algorithm, this work examines percent depth dose curves of the central axis in an acrylic phantom (20x20x20 cm"3) with variously sized air cavities (20x20x1.0, 20x20x2.0, 20x20x3.0, 20x20x4.0 and 20x20x4.95 cm"3 for study of longitudinal electron disequilibrium (ED) and 3.6x3.6x4.95, 4.5x4.5x4.95, 5.4x5.4x4.95 and 20x20x4.95 cm"3 for study of lateral ED). Radiochromic film samples are also measured to verify the Monte Carlo results. The Monte Carlo simulation is performed using OMEGA/BEAM and DOSXYZ codes, and the convolution/superposition calculation relies on an ADAC commercial treatment planning system. Underestimating the dose kernel expansion leads to overestimating the dose of what was found in the air cavity of ED using the convolution/superposition algorithm. Consequently, the dose in the rebuild-up region is ...
2002-12-01
Energy Technology Data Exchange (ETDEWEB)
The distribution of carrier free lead-203 between plasma and cells of canine blood in vitro was measured. Activity in the plasma decreased to less than 5% of the initial blood activity during the first 15 min and then exponentially with a half time of 160 min. Incubation in cell free plasma before addition to whole blood transformed the isotope, decreasing the amount subsequently associated with cells. In animal studies, activity was measured in plasma, blood cells, urine, and feces after exposure to lead-203. In one group, the animals were exposed by intravenous injection of dilute citric acid solutions of isotope. In a second group, carrier free isotope which had been transformed by incubation in plasma was injected intravenously. The kinetics of the distribution of the isotope differed between the two experimental groups. After injection of the transformed lead, the lead-203 content of the blood cell fraction rose from 10% of the dose at 5 min to 21% to 43% at ...
1980-01-01
Energy Technology Data Exchange (ETDEWEB)
Hepatocellular carcinoma (HCC) is the most common primary liver cancer and has very limited therapeutic options. Recently, it has been found that hyaluronic acid (HA) shows selective binding to CD44 receptors expressed in most cancer histotypes. Since the trend in cancer treatment is the use of targeted radionuclide therapy, the aim of this research was to label HA with rhenium-188 and to evaluate its potential use as a hepatocarcinoma therapeutic radiopharmaceutical. Methods: {sup 188}Re-HA was prepared by a direct labelling method to produce a ReO(O-COO){sub 2}-type coordination complex. {sup 188}Re-HA protein binding and its stability in saline, phosphate buffer, human serum and cysteine solutions were determined. Biokinetic and dosimetric data were estimated in healthy mice (n=60) using the Medical Internal Radiation Dose methodology and mouse model beta-absorbed fractions. To evaluate liver toxicity, alanine aminotranferase (AST) and ...
2009-08-15
Potential Hazards from Neutrino Radiation at Muon Colliders
High energy muon colliders, such as the TeV-scale conceptual designs now being considered, are found to produce enough high energy neutrinos to constitute a potentially serious off-site radiation hazard in the neighbourhood of the accelerator site. A general characterization of this radiation hazard is given, followed by an order-of-magnitude calculation for the off-site annual radiation dose and a discussion of accelerator design and site selection strategies to minimize the radiation hazard.
1999-01-01
International Nuclear Information System (INIS)
From the frequency of diagnostic radiologic examinations and their radiation dose delivered to the population the risk of cancer induction and genetic damage is calculated on the basis of the risk factors given by the ICRP. Thus 0.38 % and 3 % of the total mortality for cancer and leukemia, resp., can be attributed to X-ray diagnostics. Chest examinations alone result in 0.07-0.7 damages per 100,000 persons depending on the imaging technique applied. (author).
1984-01-01
Measurement and apportionment of radon source terms for modeling indoor environments
Energy Technology Data Exchange (ETDEWEB)
This research has two main goals; (1) to quantify mechanisms for radon entry into homes of different types and to determine the fraction of indoor radon attributable to each source and (2) to model and calculate the dose (and therefore alpha particle fluence) to cells in the human and animal tracheobronchial tree that is pertinent to induction of bronchogenic carcinoma from inhaled radon daughters.
1990-01-01
Clinical helical tomotherapy commissioning dosimetry
International Nuclear Information System (INIS)
Helical tomotherapy presented many unique dosimetric challenges and solutions during the initial commissioning process, and some of them are presented. The dose calculation algorithm is convolution/superposition based. This requires that the energy fluence spectrum and magnitude be quantified. The methodology for doing so is described. Aspects of the energy fluence characterization that are unique to tomotherapy are highlighted. Many beam characteristics can be measured automatically by an included megavoltage computed tomography imaging system. This greatly improves data collection efficiency.
2003-12-01
Mean glandular doses for women undergoing mammographic breast screening in Oyo state, Nigeria
British Library Electronic Table of Contents (United Kingdom)
In this work, thermoluminescent dosimeters have been used to measure entrance surface doses (ESDs) of patients undergoing mammographic screening at the University College Hospital, Ibadan, Oyo state. The mean glandular doses (MGDs) were also calculated using the measured ESDs. The results showed that the ESDs ranged from 0.26mGy to 21.26mGy for the mediolateral oblique (MLO) views and 0.08mGy to 5.36mGy for the craniocaudal (CC) views. The calculated MGD ranged from 0.07mGy to 3.57mGy for the MLO views and 0.02mGy to 0.98mGy for the CC views. The possible reasons for the large variations in the individual ESD values and MGD values for both views are discussed using patients data, equipment specific data and the technical parameters used for the examinations. Comparison showed that the mean...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
Plutonium-containing compounds vary widely in isotopic content, and as a result, the dose as function of isotopic content also varies considerably. Determination of the dose from neutrons, decay and capture gammas from plutonium in the form of compounds thus requires that the spontaneous fission and ({alpha},n) source and spectra from each individual isotope be known. To facilitate dose calculations from plutonium-containing compounds, we have calculated the spontaneous fission and ({alpha},n) sources and spectra for 1 g of each of the plutonium isotopes in the form of either PuF{sub 4} or PuO{sub 2}. As {sup 241}Am is often a component in a mixture of plutonium isotopic compounds, the source and spectra from 1 g of {sup 241}Am mixed with PuF{sub 4} or PuO{sub 2} has also been determined. Using these results, the neutron source and spectra may be determined for any sample ...
1996-10-01
Antimicrobials in the Management of Post-Irradiation Infection
... develops. An alternative approach is the use of non-absorbable antibiot- ics such as polymyxin, neomycin, and bacitracin. ...
2011-05-13
International Nuclear Information System (INIS)
The Seismic Proving Test of Heavy Component with Energy Absorbing Supports has been conducted to prove the reliability of advanced seismic technology, supporting heavy component such as PWR steam generator with large capacity energy absorbing supports under the sponsorship of Ministry of Economical Trade and Industry. If energy absorbing supports are adopted for NPP heavy components, support structure of facility will be much simplified due to their seismic energy absorbing effect. The paper describes the results of lead damper element test and seismic test at Tadotsu Laboratory, using 1/2.5 scale PWR Steam Generator model supported by Lead Extraction Damper (LED) and development of characteristics evaluation formula of energy absorbing support. (author)
2003-09-15
Tissue equivalent proportional counter real time neutron monitor
International Nuclear Information System (INIS)
The Tissue Equivalent Proportional Counter (TEPC) was developed to monitor low level neutron exposure rates at working stations in a nuclear fuel fabrication facility. It has proven capable of accurately measuring neutron dose rates at levels from 0.1 to 0.2 mrem/hr. It also calculates the Quality Factor which is of importance in locations where the neutron to gamma ratio may vary significantly and irregularily. The system described is computerized to monitor 100 work locations simulationeously and can be expanded to monitor 384 locations. Neutron dose is accumulated on a real time basis and after the proton drop point is established, dose rate can be read out at any time for the dose accumulated over a specified period of time. The current development program which provides reduced system maintenance, lower detection limits, and improved accuracy is discussed along with examples of ...
1978-10-25
Slide Rule for Rapid Response Estimation of Radiological Dose from Criticality Accidents
Energy Technology Data Exchange (ETDEWEB)
This paper describes a functional slide rule that provides a readily usable ?in-hand? method for estimating nuclear criticality accident information from sliding graphs, thereby permitting (1) the rapid estimation of pertinent criticality accident information without laborious or sophisticated calculations in a nuclear criticality emergency situation, (2) the appraisal of potential fission yields and external personnel radiation exposures for facility safety analyses, and (3) a technical basis for emergency preparedness and training programs at nonreactor nuclear facilities. The slide rule permits the estimation of neutron and gamma dose rates and integrated doses based upon estimated fission yields, distance from the fission source, and time-after criticality accidents for five different critical systems. Another sliding graph permits the estimation of critical solution fission yields based upon fissile material ...
1999-09-20
Optimisation of imaging technique used in direct digital radiography
Energy Technology Data Exchange (ETDEWEB)
The purpose of the study was to optimise the technique employed for AP shoulder and lateral cervical spine examinations following an investigation into image quality, based on clinical assessment, and effective dose, calculated from patient entrance surface dose measurements. A study was therefore conducted in an attempt to determine whether the increased radiation dose to the patient following the introduction of an anti-scatter grid was justified by the level of improvement in image quality. The study, involving 100 patients, was able to demonstrate that the increase in radiation dose to the patient when using an anti-scatter grid for AP shoulder examinations is not justified by the improved image quality. A poor level of inter-rater reliability between the consultants scoring the lateral cervical spine images prevented a firm conclusion from being reached. The fact that all ...
2006-09-15
Optimisation of imaging technique used in direct digital radiography
International Nuclear Information System (INIS)
The purpose of the study was to optimise the technique employed for AP shoulder and lateral cervical spine examinations following an investigation into image quality, based on clinical assessment, and effective dose, calculated from patient entrance surface dose measurements. A study was therefore conducted in an attempt to determine whether the increased radiation dose to the patient following the introduction of an anti-scatter grid was justified by the level of improvement in image quality. The study, involving 100 patients, was able to demonstrate that the increase in radiation dose to the patient when using an anti-scatter grid for AP shoulder examinations is not justified by the improved image quality. A poor level of inter-rater reliability between the consultants scoring the lateral cervical spine images prevented a firm conclusion from being reached. The fact that all ...
2006-09-01
Mechanisms of renal handling of lead
International Nuclear Information System (INIS)
The relative roles of glomerular filtration, tubular reabsorption and tubular secretion in lead handling were evaluated using renal clearance technique, stop-flow analysis, and renal lead accumulation. In addition, the effect of altering acid-base status on renal handling of Pb was determined. Clearance of ultrafilterable lead was measured in anesthetized dogs during infusion of "2"0"3Pb with small doses of carrier Pb(0.5 to 50 #mu#g/kg/h). Filterable lead concentration was estimated by in vitro ultrafiltration of non-anticoagulated plasma. Fractional excretion of Pb was calculated using creatinine clearance to estimate glomerular filtration rate. Dogs in acute metabolic acidosis had the lowest fractional excretion of ultrafilterable Pb (< 0.1); those in alkalosis had high fractional Pb excretion (0.75 to 2.5) while normal dogs were intermediate (0.1 to .4). The fractional excretion of Pb during metabolic alkalosis varied with the ...
Dosimetric characteristics of backscattered electrons in lead
Energy Technology Data Exchange (ETDEWEB)
In electron beam therapy, tissue overdose due to electrons backscattered from lead has been profusely studied. To quantify this dose enhancement effect, an electron backscatter factor (EBF) wasdefined as the ratio of dose at the tissue-inhomogeneity interface with and without the scatterer present. The dependence of the EBF on energy at the scatterer surface is not well known for energies lower than 3 MeV which is the most frequent clinical situation. In this work, we have done Monte Carlo calculations with the GEANT code to study EBF in lead at this energy range. The applicability of this code and the developed procedure for dose estimation has been experimentally verified. The dependence of the EBF on the beam energy incident on the scatterer has been studied for different nominal beam energies incident at the phantom's surface. The results show a trend of increase of EBF with the beam energy ...
2000-07-01
Radiation-induced reduction of ditetrazolium salt in aqueous solutions
Energy Technology Data Exchange (ETDEWEB)
Color formation in aqueous solutions of the ditetrazolium salt blue tetrazolium (BT{sup 2+}) in the absence or presence of oxygen is a complex radiation chemical reaction. The final stable product is the poorly soluble diformazan violet to blue pigment having a broad spectral absorption band ({lambda}{sub max}=552 nm). The reaction of BT{sup 2+} with the hydrated electron proceeds by rapid reduction of BT{sup 2+} followed by protonation at the nitrogen closest to the unsubstituted phenyl group, via the two intermediate tetrazolinyl radicals shared by the ditetrazole ring nitrogens. The effect of solution pH, N{sub 2}O saturation, and the presence of the reducing agent dextrose are examined. The system serves as a radiochromic sensor and a dosimeter of ionizing radiations. Solutions of 5 mmol l{sup -1} BT{sup 2+} at pH 7.3 serve as dosimeters over an absorbed-dose range of approximately 0.2-6 kGy (dearated, with a range of 1-8 mmol l{sup -1} dextrose) and of about ...
2002-04-01
ESR/Alanine dosimetry on Wolsung Unit 1
Energy Technology Data Exchange (ETDEWEB)
Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement result shows extremely high radiation level ...
2007-07-01
ESR/Alanine dosimetry on Wolsung Unit 1
International Nuclear Information System (INIS)
Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement result shows extremely high radiation level ...
2007-05-10
Bioavailability of lead in rats fed human diets
International Nuclear Information System (INIS)
The bioavailability of lead was studied in rats fed various baby foods (Babymix-turkey, Babymix-vegetables, Frutolino-fruit, Frutamix-bananas, Babyron-S-26, Truefood), cow's milk, bread, liver and standard rat diet. Lead absorption was determined by measuring the whole body retention of "2"0"3Pb 6 days after a single oral application. Highest absorption values ranging from 17 to 20% were obtained in animals fed cow's milk and fruit foods. Rats on other human diets absorbed between 3 and 8% of the radioactive lead dose. Only in animals on rat diet lead absorption was below 1%. It is concluded that rats fed human diets show absorption values similar to those in humans. This might indicate that the bioavailability of lead is primarily dependent on dietary habits. This experimental model, if confirmed by further work, might be useful for obtaining preliminary data on the bioavailability of metals from various foods.
Radioimmunoassay data processing, ch. 2
International Nuclear Information System (INIS)
The problems of radioimmunoassay data processing with a fairly big computer are investigated in detail. The logit transformation, introduced by Rodbard et al. in 1968, and the related mathematical operations are presented. From logit-ln plots the confidence limits for the calculation of the antigen concentration can be predicted as well as the minimum detectable dose (i.e. the sensitivity of the assay). The Scatchard plot is used to calculate the equilibrium constant of the antigen-antibody coupling reaction and the binding capacity. A 4-parameter logistic curve fitting method is developed and combined with a method to carry out a multi-component Scatchard analysis. Both a weighted and an unweighted linear regression procedure are evaluated for use in calculating the plasma renin activity from the angiotensin I amounts determined by radioimmunoassay. Improvements for Rodbard's computer programmes are ...
1978-02-15
International Nuclear Information System (INIS)
The goal of this work is to present a systematic Monte Carlo validation study on the clinical implementation of the enhanced dynamic wedges (EDWs) into the Pinnacle"3 (Philips Medical Systems, Fitchburg, WI) treatment planning system (TPS) and QA procedures for patient plan verification treated with EDWs. Modeling of EDW beams in the Pinnacle"3 TPS, which employs a collapsed-cone convolution superposition (CCCS) dose model, was based on a combination of measured open-beam data and the 'Golden Segmented Treatment Table' (GSTT) provided by Varian for each photon beam energy. To validate EDW models, dose profiles of 6 and 10 MV photon beams from a Clinac 2100 C/D were measured in virtual water at depths from near-surface to 30 cm for a wide range of field sizes and wedge angles using the Profiler 2 (Sun Nuclear Corporation, Melbourne, FL) diode array system. The EDW output factors (EDWOFs) for square fields from 4 to 20 cm wide were measured in ...
2009-01-21
Energy Technology Data Exchange (ETDEWEB)
Potential maximum radiation dose rates over a 1,000-year time horizon were calculated for exposure to the decontaminated concrete removed from the 183-H Solar Evaporation Basins at the Hanford Site, Richland, Washington. The RESRAD computer code, Version 5.62, which implements the methodology described in the US Department of Energy`s manual for developing residual radioactive material guidelines, was used in this evaluation. Currently, the concrete is not being used. Four potential exposure scenarios were developed for the land area where the decontaminated concrete will be stored. In Scenario A industrial use of the land is assumed; in Scenario B recreational use of the land is assumed; in Scenario C residential use of the land is assumed; and in Scenario D (a plausible but unlikely land-use scenario), the presence of a subsistence farmer in the immediate vicinity of the land is assumed. For Scenarios A and B, water used for drinking is ...
1997-01-01
Performance assessment for the disposal of low-level waste in the 200 east area burial grounds
Energy Technology Data Exchange (ETDEWEB)
A performance assessment analysis was completed for the 200 East Area Low-Level Burial Grounds (LLBG) to satisfy compliance requirements in DOE Order 5820.2A. In the analysis, scenarios of radionuclide release from the 200 East Area Low-Level waste facility was evaluated. The analysis focused on two primary scenarios leading to exposure. The first was inadvertent intrusion. In this scenario, it was assumed that institutional control of the site and knowledge of the disposal facility has been lost. Waste is subsequently exhumed and dose from exposure is received. The second scenario was groundwater contamination.In this scenario, radionuclides are leached from the waste by infiltrating precipitation and transported through the soil column to the underlying unconfined aquifer. The contaminated water is pumped from a well 100 m downstream and consumed,causing dose. Estimates of potential contamination of the surrounding environment were developed ...
1996-08-15
Concepts in radiation protection
International Nuclear Information System (INIS)
This monograph provides basic notions and principles in dosimetry and radiation protection in compliance with two fundamental works: IAEA Safety Series No.115 - International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources - and Publication no. 60 of International Commission on Radiological Protection. After the review of quantities and units necessary in radiation protection, the book presents the new values of dose limits as well as the values of 'radiation weighting factor', 'tissue weighting factor' and 'conversion factor intake-dose' (committed effective dose per unit intake) by ingestion and inhalation for 30 most important radionuclides. The new values of dose limits, lower than the old values, are a challenge for the radiation protection, especially of the 'public' where the dose limit diminished by a factor of five ...
1996-01-01
Energy Technology Data Exchange (ETDEWEB)
A comprehensive attenuation data of dose equivalent for point isotropic monoenergetic neutron sources up to 400MeV in infinite shields of water, ordinary concrete and iron has been calculated using the ANISN-JR code and a neutron-photon multigroup macroscopic cross section HIL086R. The attenuation factors were fitted to a 4th order polynomial exponent formula, making possible to use easily for point kernel codes. Additional data in finite shielding geometry was also calculated to correct the effect due to infinite medium, giving the maximum correction of 0.23 in the region for more 400 cm distance from neutron source of 400 MeV in iron shield. Effective attenuation length for monoenergetic neutrons have been studied in detail. Subsequently, it was shown that the attenuation length was strongly dependent upon the penetration length and the Moyer`s formula using a single attenuation length brought large error into the ...
1994-08-01
International Nuclear Information System (INIS)
For the Convolution, Superposition and Monte Carlo methods, energy spectrum data is an essential parameter. Especially, by using Monte Carlo method, if the adequate properties of electrons are set, complex energy spectrum data can be calculated by simple input. However, adjustment of the property of electrons incident on the target of linear accelerator is time-consuming procedure. To cover the difference of many accelerators, it is important how we obtain accurate energy spectrum by simple methods. Especially, the total accuracy of dose calculation depends on the agreement of measured and calculated percentage depth dose (PDD) and off-axis ratio (OAR). Thus, a simple method for the determination of the simulation parameters was considered. To reduce the adjustment procedure, we selected values of important three parameters, which were the mean energy of the input electron beam, the ...
2005-06-01
International Nuclear Information System (INIS)
In the convolution/superposition method of photon beam dose calculations, inhomogeneities are usually handled by using some form of scaling involving the relative electron densities of the inhomogeneities. In this paper the accuracy of density scaling as applied to primary electrons generated in photon interactions is examined. Monte Carlo calculations are compared with density scaling calculations for air and cork slab inhomogeneities. For individual primary photon kernels as well as for photon interactions restricted to a thin layer, the results can differ significantly, by up to 50%, between the two calculations. However, for realistic photon beams where interactions occur throughout the whole irradiated volume, the discrepancies are much less severe. The discrepancies for the kernel calculation are attributed to the scattering characteristics of the ...
Energy Technology Data Exchange (ETDEWEB)
An estimate of the tritium dose to the public in the vicinity of the heavy water research reactor facility at AECL-Chalk River Laboratories, Ontario, Canada, has largely been accomplished from analyses on regularly-collected samples of air, precipitation, drinking water and foodstuffs (pasture, fruit, vegetables and milk) and environmental dose models. To increase the confidence with which public doses are calculated, tritium doses were estimated directly from the ratio of tritiated species in urine samples from members of the general public. Single cumulative 24 h urine samples from a few adults living in the vicinity of the heavy-water research reactor facility at Chalk River Laboratories, Canada were collected and analysed for tritiated water and organically bound tritium. The participants were from Ottawa (200 km east), Deep River (10 km west) and Chalk River Laboratories. ...
2001-07-01
Energy Technology Data Exchange (ETDEWEB)
Background and purpose: the recent RTOG guidelines for future clinical developments in gynecologic malignancies included the investigation of dose escalation in the paraaortic (PO) region which is, however, very difficult to target due to the presence of critical organs such as kidneys, liver, spinal cord, and digestive structures. The aim of this study was to investigate intensity-modulated radiotherapy's (IMRT) possibilities of either increasing, in a safe way, the dose to 50-60 Gy in case of macroscopic disease or decreasing the dose to organs at risk (OR) when treatment is given in an adjuvant setting. Material and methods: the dosimetric charts of 14 patients irradiated to the PO region at the department of radiation oncology, university hospital of Liege, Belgium, in 2000 were analyzed in order to compare six-field conformal external-beam radio-therapy (CEBR) and five-beam IMRT approaches. Both CEBR and IMRT ...
2005-03-01
International Nuclear Information System (INIS)
The Anisotropic Analytical Algorithm (AAA) is a new pencil beam convolution/superposition algorithm proposed by Varian for photon dose calculations. The configuration of AAA depends on linear accelerator design and specifications. The purpose of this study was to investigate the accuracy of AAA for an Elekta SL25 linear accelerator for small fields and intensity modulated radiation therapy (IMRT) treatments in inhomogeneous media. The accuracy of AAA was evaluated in two studies. First, AAA was compared both with Monte Carlo (MC) and the measurements in an inhomogeneous phantom simulating lung equivalent tissues and bone ribs. The algorithm was tested under lateral electronic disequilibrium conditions, using small fields (2x2 cm"2). Good agreement was generally achieved for depth dose and profiles, with deviations generally below 3% in lung inhomogeneities and below 5% at interfaces. However, the effects of attenuation and ...
2007-05-01
Mean glandular doses for women undergoing mammographic breast screening in Oyo state, Nigeria
Energy Technology Data Exchange (ETDEWEB)
In this work, thermoluminescent dosimeters have been used to measure entrance surface doses (ESDs) of patients undergoing mammographic screening at the University College Hospital, Ibadan, Oyo state. The mean glandular doses (MGDs) were also calculated using the measured ESDs. The results showed that the ESDs ranged from 0.26 mGy to 21.26 mGy for the mediolateral oblique (MLO) views and 0.08 mGy to 5.36 mGy for the craniocaudal (CC) views. The calculated MGD ranged from 0.07 mGy to 3.57 mGy for the MLO views and 0.02 mGy to 0.98 mGy for the CC views. The possible reasons for the large variations in the individual ESD values and MGD values for both views are discussed using patients' data, equipment specific data and the technical parameters used for the examinations. Comparison showed that the mean ESD values and MGD values reported in this work are below published values. The mean of the ...
2009-11-15
Mean glandular doses for women undergoing mammographic breast screening in Oyo state, Nigeria
International Nuclear Information System (INIS)
In this work, thermoluminescent dosimeters have been used to measure entrance surface doses (ESDs) of patients undergoing mammographic screening at the University College Hospital, Ibadan, Oyo state. The mean glandular doses (MGDs) were also calculated using the measured ESDs. The results showed that the ESDs ranged from 0.26 mGy to 21.26 mGy for the mediolateral oblique (MLO) views and 0.08 mGy to 5.36 mGy for the craniocaudal (CC) views. The calculated MGD ranged from 0.07 mGy to 3.57 mGy for the MLO views and 0.02 mGy to 0.98 mGy for the CC views. The possible reasons for the large variations in the individual ESD values and MGD values for both views are discussed using patients' data, equipment specific data and the technical parameters used for the examinations. Comparison showed that the mean ESD values and MGD values reported in this work are below published values. The mean of the ...
2009-11-01
Transuranic radionuclides dispersed into the environment at accident sites, a bibliography
Energy Technology Data Exchange (ETDEWEB)
The purpose of this project was to compile a bibliography of references containing environmental transuranic radionuclide data. The authors intent was to identify those parameters affecting transuranic radionuclide transport that may be generic and those that may be dependent on chemical form and/or environmental conditions. An understanding of the unique characteristics and similarities between source terms and environmental conditions relative to transuranic radionuclide transport and cycling will provide the ability to assess and predict the long term impact on man and the environment. An additional goal of the literature review, was to extract the ranges of environmental transuranic radionuclide data from the identified references for inclusion in a data base. Related to source term, these ranges of data can be used to calculate the dose to man from the radionuclides, and to perform uncertainty analyses on these dose ...
1994-07-01
Studies on natural radioactivity of some egyptian building materials
International Nuclear Information System (INIS)
Using high-resolution y-rays spectrometry, the natural radioactivity of 14 samples of natural and o manufactured Egyptian building materials have been investigated. The samples were collected from local market and construction sites. From the measured gamma-ray spectra, specific activities were determined. The radium equivalent activity in each sample was estimated. Radiological evaluations of these materials indicate that all materials meet the external gamma-ray dose limitation. Calculation of concentration indices by assuming a Markkanen room model is constructed from these materials, to find the excess gamma-ray dose taken over that received from the outdoors. The Austrian Standard ONORM S 5200 is used in testing the building materials.
2004-02-24
Shielding augmentation for HFU penetration in calandria vault of 540 MWe PHWR
International Nuclear Information System (INIS)
This paper consists the radiation streaming analysis of Horizontal Flux Unit (HFU) penetrations in Calandria Vault of 540 MWe PHWR. There are total 7 HFU penetrations on west wall of calandria vault. As these penetrations are in accessible area, a detailed analysis has been carried out to find the neutron and gamma dose rates around these penetrations when reactor is operating. Analysis has been carried out Using the computer code MCNP and DOT-III. Based on the predictions at HFU penetrations, shielding arrangement was recommended. Neutron and gamma dose rate higher than estimated were observed at TAPS-4. This was because of installed shield not being similar to recommended one due to site conditions. Subsequently semi-empirical calculations using measured data were carried out by MCNP to further augment the existing shield taking into consideration the space limitations at site. (author)
2006-11-13
Interinstitutional Variations in Planning for Stereotactic Body Radiation Therapy for Lung Cancer
British Library Electronic Table of Contents (United Kingdom)
Purpose: The aim of this study was to assess interinstitutional variations in planning for stereotactic body radiation therapy (SBRT) for lung cancer before the start of the Japan Clinical Oncology Group (JCOG) 0403 trial.Methods and Materials: Eleven institutions created virtual plans for four cases of solitary lung cancer. The created plans should satisfy the target definitions and the dose constraints for the JCOG 0403 protocol.Results: FOCUS/XiO (CMS) was used in six institutions, Eclipse (Varian) in 3, Cadplan (Varian) in one, and Pinnacle3 (Philips/ADAC) in one. Dose calculation algorithms of Clarkson with effective path length correction and superposition were used in FOCUS/XiO; pencil beam convolution with Batho power law correction was used in Eclipse and Cadplan; and collapsed co...
2007-01-01
Atomic scale simulations of arsenic ion implantation and annealing in silicon
International Nuclear Information System (INIS)
We present results of multiple-time-scale simulations of 5, 10 and 15 keV low temperature ion implantation of arsenic on silicon (100), followed by high temperature anneals. The simulations start with a molecular dynamics (MD) calculation of the primary state of damage after 10ps. The results are then coupled to a kinetic Monte Carlo (MC) simulation of bulk defect diffusion and clustering. Dose accumulation is achieved considering that at low temperatures the damage produced in the lattice is stable. After the desired dose is accumulated, the system is annealed at 800 degrees C for several seconds. The results provide information on the evolution for the damage microstructure over macroscopic length and time scales and affords direct comparison to experimental results. We discuss the database of inputs to the MC model and how it affects the diffusion process.
2004-12-15
Assessment and control of fetal exposure
Energy Technology Data Exchange (ETDEWEB)
The assessment and control of fetal exposure to radiation in the workplace is an issue that is complicated by both biological and political/social ramifications. As a result of the dramatic increase in the number of women employed as radiation workers during the past 10 years, many facilities using radioactive materials have instituted fetal protection programs with special requirements for female radiation workers. It is necessary, however, to ensure that any fetal protection program be developed in such a way as to be nondiscriminatory. A study has been initiated whose purpose is to balance the political/social and the biological ramifications associated with occupational protection of the developing embryo/fetus. Several considerations are involved in properly balancing these factors. These considerations include appropriate methods of declaring the pregnancy, training workers, controlling the dose to the embryo/fetus, measuring and ...
1991-10-01
A note on neutron irradiation effects on transition temperature of A-15 superconducting materials
International Nuclear Information System (INIS)
The change of superconducting properties after neutron irradiation in A-15 compounds such as Nb_3Sn. Nb_3Al. V_3Ca and V_3Si has been examined. Using the model based on the damage function, the change of transition temperature corresponding to an arbitrary irradiation dose within about 10"2"0n/cm"2 can be predicted with an accuracy of several percent for Nb_3Al. Nb_3Sn and V_3Si if experimental data, namely a pair of irradiation dose and transition temperature, is given. The calculation of transition temperature of neutron irradiated A-15 compounds is much more straightforward than in the case of Pande's model. (author).
International Nuclear Information System (INIS)
In July 2005 a new algorithm was released by Varian Medical Systems for the Eclipse planning system and installed in our institute. It is the anisotropic analytical algorithm (AAA) for photon dose calculations, a convolution/superposition model for the first time implemented in a Varian planning system. It was therefore necessary to perform validation studies at different levels with a wide investigation approach. To validate the basic performances of the AAA, a detailed analysis of data computed by the AAA configuration algorithm was carried out and data were compared against measurements. To better appraise the performance of AAA and the capability of its configuration to tailor machine-specific characteristics, data obtained from the pencil beam convolution (PBC) algorithm implemented in Eclipse were also added in the comparison. Since the purpose of the paper is to address the basic performances of the AAA and of its configuration ...
2006-03-21
Real-time monitoring of dosimetry and image quality during digital radiology examinations
International Nuclear Information System (INIS)
Objective: To explore the feasibility of real-time monitoring exposure dose and image quality by using the data stored in the DICOM image archive of direct digital radiography system. Methods: Model TO. 16 was exposed, the current increased gradually from 0.5 to 125 mAs. The displayed number of model A( diameter 11.1 mm), D (diameter 4.0 mm) and J( diameter 0.7 mm) were recorded, and the detect factors (H_T) was also calculated. Images were sent to workstation before the end of DR examination. An automatic procedure was implemented to extract dose data and exposure parameters from the DICOM header file. Maximum, minimum and 3rd quartile values were preinstalled. Mean values exceeding the threshold trigger alarm signal to guide radiologist to explore the cause. Results: When the current of point A was less than 10 mAs and the current of point D and J were less than 16 mAs, the detect factor (H_T) increased with the rise of ...
2009-12-01
Energy Technology Data Exchange (ETDEWEB)
It is planned to use the tritium dose model, DCART (Doses from Chronic Atmospheric Releases of Tritium), to reconstruct dose to the hypothetical maximally exposed individual from annual routine releases of tritiated water (HTO) and tritiated hydrogen gas (HT) from all Lawrence Livermore National Laboratory (LLNL) facilities and from the Sandia National (SNL) Laboratory's Tritium Research Laboratory over the last fifty years. DCART has been described in Part 1 of ''Historical Doses From Tritiated Water And Tritiated Hydrogen Gas Released To The Atmosphere from Lawrence Livermore National Laboratory (LLNL)'' (UCRL-TR-205083). This report (Part 2) summarizes information about annual routine releases of tritium from LLNL (and SNL) since 1953. Historical records were used to derive facility-specific annual data (e.g., source terms, dilution factors, ambient air ...
2005-03-07
Feasibility of delivering grid therapy using a multileaf collimator
International Nuclear Information System (INIS)
The feasibility of using a multileaf collimator (MLC) for grid therapy is demonstrated in this study. Grids with the projected field openings of 10 mmx10 mm and 5 mmx5 mm were created using multiple MLC-shaped fields. The deposited doses were measured with films at different depths in a solid water phantom and compared to those of Cerrobend grid collimators of similar hole sizes and hole separations. At the depth of maximum dose (d_m_a_x), the valley-to-peak dose ratios of the MLC grids were found to be about 11% and 19% for the respective 10 mmx10 mm and 5 mmx5 mm grid openings, and those of the corresponding grid blocks were about 15% and 20%. To quantify the dose contributed by transmission in the blocked areas due to the limited leaf thickness, Monte Carlo simulations (based on convolution/superposition method) were performed to calculate the doses in the ...
2006-01-01
Energy Technology Data Exchange (ETDEWEB)
Existing test procedures for measuring and rating thermal performance require the determination of the angular response of collectors in order to account for nonnormal incident beam irradiance. Angular response measurements for four different types of collectors, each type tested by three different laboratories, are presented and analyzed. Substantial differences, both within and between laboratories, are reported for the same type collectors. An analysis of the measurement procedure shows that experimentally determined angular response parameters are subject to relatively large uncertainties. The problem results to a large extent from measuring collector efficiencies at non-normal incident angles where measurement uncertainty is of the same order of magnitude as the efficiency reduction attributable to these off-normal angles. Other factors which can affect angular response measurements and the method of correlating results are also discussed. A theoretical analysis shows that shading ...
1982-11-01
The Development of 6061-Aluminum Windows for the MICE LiquidAbsorber
Energy Technology Data Exchange (ETDEWEB)
The thin windows for the Muon Ionization Cooling Experiment (MICE) liquid Absorber will be fabricated from 6061-T6-aluminum. The absorber and vacuum vessel thin windows are 300-mm in diameter and are 180 mm thick at the center. The windows are designed for an internal burst pressure of 0.68 MPa (100 psig) when warm. The MICE experiment design calls for changeable windows on the absorber, so a bolted window design was adopted. Welded windows offer some potential advantages over bolted windows when they are on the absorber itself. This report describes the bolted window and its seal. This report also describes an alternate window that is welded directly to the absorber body. The welded window design presented permits the weld to be ground off and re-welded. This report presents a thermal FEA analysis of the window seal-weld, while the window is being welded. Finally, the results of a ...
2005-08-24
Energy Technology Data Exchange (ETDEWEB)
This report uses experimental data to compare the performance of two sodium cooled solar central receivers operated at the International Energy Agency Small Solar Power Systems project near Almeria, Spain. Performance includes point-in-time steady state efficiency, average efficiency, start-up time, and operation time. Point-in-time steady state efficiency calculations were based on the statistical method of least squares using receiver incident and absorbed powers. One receiver, a cavity type, showed a peak steady state receiver efficiency of 87% +- 5% and an average efficiency of about 67%. The other receiver, an external ''billboard'' type, had a peak steady state receiver efficiency of 96% +- 4% and an average efficiency of about 79%. The original design peak steady state efficiency predictions for both receivers were within the experimentally determined 95% probability interval. Thermal loss test data ...
1987-10-01
Concepts of radiotherapy treatment planning
International Nuclear Information System (INIS)
Full text: Radiotherapy treatment planning (RTP) relies heavily on medical imaging. Until recently, the most important planning tool was the treatment simulator. The kilovoltage radiographic capabilities in a treatment simulator enabled the boundaries of treatment fields to be visualized with respect to bony anatomic landmarks. Perhaps the most important advance in treatment planning in recent years is the ability to visualize the passage of the beams with respect to a more accurate geometrical representation of the tumor and other soft tissue structures. This 'virtual simulation' uses a computer-based representation of a patient to determine the extent of the disease and the location of radiation sensitive normal tissue. Computer tomographic (CT) imaging produces a high-resolution three-dimensional representation of anatomy that can be correlated with other image sets such as magnetic resonance images (MRI) of function. Positron emission tomographic (PET) imaging is beginning to be ...
2000-12-01
Technology of iodine-131 production and its application
International Nuclear Information System (INIS)
Full text: Production: This radio iodine produced by three methods: 1) Wet method: The irradiated tellurium is dissolved in an oxidizing mixture which also converts iodine in to iodide. This is a chemical method and iodine that it produced with this method has low purity and efficiency. 2). Dry Method: The irradiated tellurium is dissolved in furnace (750 deg. C) with sublimation method and iodine absorbed in sodium solution . In this case we have more than 99.5 % purity and 80 % efficiency. We are using this type in Iran. 3) Fission fragment method: In this case the iodine separated from fission fragment directly and we have high purity (career free) and specific activity of iodine. Application: Iodine is a versatile tracer element. It is used to determine thyroid cancer metastases, and size, shape and activity of the thyroid gland. Critical organ of iodine is thyroid gland. One of the common diagnostic procedures for determining thyroid function therefore, is to ...
Radiation testing of organic ion exchange resins
International Nuclear Information System (INIS)
A number of ion exchange materials are being evaluated as part of the Tank Waste Remediation System (TWRS) Pacific Northwest Laboratory (PNL) Pretreatment Project for the removal of "1"3"7Cs from aqueous tank wastes. Two of these materials are organic resins; a phenol-formaldehyde resin (Duolite CS-100) produced by Rohm and Haas Co. (Philadelphia, Pennsylvania) and a resorcinol-formaldehyde (RF) resin produced by Boulder Scientific Co. (Mead, Colorado). One of the key parameters in the assessment of the organic based ion exchange materials is its useful lifetime in the radioactive and chemical environment that will be encountered during waste processing. The focus of the work presented in this report is the radiation stability of the CS-100 and the RF resins. The scope of the testing included one test with a sample of the CS-100 resin and testing of two batches of the RF resin (BSC-187 and BSC-210). Samples of the exchangers were irradiated with a "6"0Co source to a total ...
1983-04-11
Radiation testing of organic ion exchange resins
Energy Technology Data Exchange (ETDEWEB)
A number of ion exchange materials are being evaluated as part of the Tank Waste Remediation System (TWRS) Pacific Northwest Laboratory (PNL) Pretreatment Project for the removal of {sup 137}Cs from aqueous tank wastes. Two of these materials are organic resins; a phenol-formaldehyde resin (Duolite CS-100) produced by Rohm and Haas Co. (Philadelphia, Pennsylvania) and a resorcinol-formaldehyde (RF) resin produced by Boulder Scientific Co. (Mead, Colorado). One of the key parameters in the assessment of the organic based ion exchange materials is its useful lifetime in the radioactive and chemical environment that will be encountered during waste processing. The focus of the work presented in this report is the radiation stability of the CS-100 and the RF resins. The scope of the testing included one test with a sample of the CS-100 resin and testing of two batches of the RF resin (BSC-187 and BSC-210). Samples of the exchangers were irradiated with a {sup 60}Co source to a total ...
1995-09-01
Prototype exposure chamber of radon for animal experiments
Energy Technology Data Exchange (ETDEWEB)
To evaluate a dose conversion factor from the `Working Level of Month` (WLM) of radon to the absorbed dose (mGy), the quality of radon and its progeny was assessed, and exposures controlled for each deposition region were planed as follows: 1) exposure of radon gas to the entire respiratory tract, 2) exposure of `unattached` fractions to the upper respiratory tract, 3) exposure of `attached` fractions onto ultrafine particles to the deep lung, 4) exposure of `attached` fractions onto fine particles to the lower respiratory tract, 5) exposure of `attached` fractions onto coarse particles to the upper respiratory tract. In this preliminary study, a prototype exposure system of radon and its progeny for small rodents was designed. A whole body exposure chamber with a volume of about 0.5 m{sup 3} was used, which it held 20 rats. The aging and mixing chamber separated by the exposure chamber had a volume of about 1 m{sup 3}. As ...
1998-12-31
Energy Technology Data Exchange (ETDEWEB)
The optically stimulated luminescence (OSL) results a highly appropriate dosimetric technique for readings of absorbed radiation 'in alive' and 'in situ', as well as in real time. The CVD diamond on the other hand presents excellent qualities like radiation reader thanks to its reproducibility, radiation resistance, biocompatibility and non toxicity. The present work studies the answer of two diamond films pure and polluted with nitrogen (750 ppm) grown by the Chemical Vapor Deposition method (CVD) on silicon substrate (001) irradiated with beta (Sr-90) in the 0.833-100 Gy interval. The optical stimulation was carried out by 40 seconds with infrared laser (830 nm, 0.36 W/cm{sup 2}) and the filter BG-39 (300-600 nm) coupled the PM. The intensity and the decay of the hyperbolic type of the LOE curves were similar in both samples, for the non doped diamond were observed trapping states in 200-380 C being compared with those that it ...
2006-07-01
Neurotoxicological effects of cinnabar (a Chinese mineral medicine, HgS) in mice
International Nuclear Information System (INIS)
Cinnabar, a naturally occurring mercuric sulfide (HgS), has long been used in combination with traditional Chinese medicine as a sedative for more than 2000 years. Up to date, its pharmacological and toxicological effects are still unclear, especially in clinical low-dose and long-term use. In this study, we attempted to elucidate the effects of cinnabar on the time course of changes in locomotor activities, pentobarbital-induced sleeping time, motor equilibrium performance and neurobiochemical activities in mice during 3- to 11-week administration at a clinical dose of 10 mg/kg/day. The results showed that cinnabar was significantly absorbed by gastrointestinal (G-I) tract and transported to brain tissues. The spontaneous locomotor activities of male mice but not female mice were preferentially suppressed. Moreover, frequencies of jump and stereotype-1 episodes were progressively decreased after 3-week oral administration ...
2007-10-15
Gastrointestinal absorption of lead (/sup 203/Pb) in chicks: influence of lead, calcium, and age
Energy Technology Data Exchange (ETDEWEB)
The present study was designed to investigate, in more detail, the mechanism of lead transport by the gastrointestinal tract and particularly the similarities or dissimilarities between lead and calcium in this process. The absorption of these metals was determined in 3-week-old white Leghorn cockerels, raised on a commercial diet or special diets, using an in vivo ligated loop procedure. The dose administered into the loop usually contained 0.5 ..mu..Ci /sup 203/Pb (and/or 0.1 ..mu..Ci /sup 47/Ca), 0.01 mM lead acetate (and/or 1 mM CaCl/sub 2/) in 0.5 ml of 0.15 M NaCl, pH 6.5. It was shown that lead is rapidly taken up by the intestinal tissue, and only slowly transferred into the circulation whereas calcium, also accumulated rapidly by the tissue, is rapidly released from the tissue in the serosal direction. The absorption processes of these cations show similar responses to various experimental conditions (low calcium intake, age of the animal, pH of the ...
1981-10-01
Energy Technology Data Exchange (ETDEWEB)
Background: The difficulty of directly measuring cellular dose is a significant obstacle to application of target tissue dosimetry for nanoparticle and microparticle toxicity assessment. As a consequence, the target tissue paradigm for dosimetry and hazard assessment of nanoparticles has largely been ignored in favor of using metrics of exposure (e.g. ?g particle/mL culture medium, particle surface area/mL, particle number/mL). We have developed a computational model of solution particokinetics (sedimentation, diffusion) and dosimetry for non-interacting spherical particles and their agglomerates in monolayer cell culture systems. Particle transport to cells is calculated by simultaneous solution of Stokes Law (sedimentation) and the Stokes-Einstein equation (diffusion). Results: The In vitro Sedimentation, Diffusion and Dosimetry model (ISDD) was tested against measured transport rates or cellular doses for multiple sizes ...
2010-11-30
Direct aperture optimization of breast IMRT and the dosimetric impact of respiration motion
International Nuclear Information System (INIS)
We have studied the application of direct aperture optimization (DAO) as an inverse planning tool for breast IMRT. Additionally, we have analysed the impact of respiratory motion on the quality of the delivered dose distribution. From this analysis, we have developed guidelines for balancing the desire for a high-quality optimized plan with the need to create a plan that will not degrade significantly in the presence of respiratory motion. For a DAO optimized breast IMRT plan, the tangential fields incorporate a flash field to cover the range of respiratory motion. The inverse planning algorithm then optimizes the shapes and weights of additional segments that are delivered in combination with the open fields. IMRT plans were generated using DAO with the relative weights of the open segments varied from 0% to 95%. To assess the impact of breathing motion, the dose distribution for the optimized IMRT plan was recalculated with the isocentre ...
2006-10-21
Using of beam spoilers in linear accelerators with photons of 10 MV
International Nuclear Information System (INIS)
This work come along of the necessity to utilize an unique High-Energy Electron Linear Accelerator (10 MV) for radiant treatments which require higher doses in the surface levels of tissue. It is analyzed the interposition of acrylic degraders (spoilers) in the beam, especially for opposed and parallel fields in the cases of head and neck. It was analyzed the possible combinations of the following parameters: 1) Field sizes defined at isocenter (100 cm) 6 x 6 cm"2, 8 x 8 cm"2 and 10 x 10 cm"2 ; 2) Surface-spoiler distance (DSS) of 4, 7 and 10 cm; 3) Spoilers with different thickness 1.1 and 1.5 cm. It was observed a displacement of the maximum dose toward the surface, and an increase in the percentile doses in the build-up zone when the spoiler is nearing and/or increasing its thickness. It is verified that the use of spoilers, support the symmetry and plane of the beam inside of the clinically acceptable margins. When the ...
1998-11-22
International Nuclear Information System (INIS)
This paper presents actual time/motion data for an oversize truck spent-fuel shipment from its origin, Surry, Virginia to its destination, Idaho National Engineering Laboratory (INEL). These data include the receipt of the empty cask at the reactor, wet-loading the cask, over-the-road or in-transit data, and receipt and dry unloading of the shipping cask at the receiving facility. Occupational doses were recorded at the Surry Power Plant as well as at INEL, and public doses were calculated for the in-transit dose analysis. This shipment was one of a series performed in support of a demonstration and evaluation of dry storage at INEL. The oversized shipment consisted of a TN-8L shipping cask loaded with three 10-yr-old pressurized water reactor assemblies. The total distance traveled was #approx#2800 miles, requiring 62 h including stops. The time required to receive and inspect the empty shipping cask ...
1988-11-04
Results of radon concentration measurements in some regions of Russia
Energy Technology Data Exchange (ETDEWEB)
Inhalation of radon and its daughter products makes the major contribution to the total exposure of the population to natural radiations. In implementing a complex ecological survey, concentrations of radon and its daughter products were measured in different regions of Russia, namely, in the St. Petersburg Region, the Central Territories and the Altay Territory. Two suitable low price versions of the dosemeters for measuring environmental radon concentrations based on track-etch and activated-charcoal detectors were used. The radon daughter product activity and the effective dose equivalents were calculated with an equilibrium factor of 0.5 and a recommended effective dose equivalent factor of 0.061 mSv (Bq m{sup -3}){sup -1}. Indoor measurements were taken in more than 1000 dwellings and public and industrial buildings of 21 towns and villages. The track chambers were exposed for about 2-3 months and the charcoal ...
1996-01-01
Results of radon concentration measurements in some regions of Russia
International Nuclear Information System (INIS)
Inhalation of radon and its daughter products makes the major contribution to the total exposure of the population to natural radiations. In implementing a complex ecological survey, concentrations of radon and its daughter products were measured in different regions of Russia, namely, in the St. Petersburg Region, the Central Territories and the Altay Territory. Two suitable low price versions of the dosemeters for measuring environmental radon concentrations based on track-etch and activated-charcoal detectors were used. The radon daughter product activity and the effective dose equivalents were calculated with an equilibrium factor of 0.5 and a recommended effective dose equivalent factor of 0.061 mSv (Bq m"-"3)"-"1. Indoor measurements were taken in more than 1000 dwellings and public and industrial buildings of 21 towns and villages. The track chambers were exposed for about 2-3 months and the charcoal detectors for ...
Dose, exposure time, and resolution in Serial X-ray Crystallography
The resolution of X-ray diffraction microscopy is limited by the maximum dose that can be delivered prior to sample damage. In the proposed Serial Crystallography method, the damage problem is addressed by distributing the total dose over many identical hydrated macromolecules running continuously in a single-file train across a continuous X-ray beam, and resolution is then limited only by the available molecular and X-ray fluxes and molecular alignment. Orientation of the diffracting molecules is achieved by laser alignment. We evaluate the incident X-ray fluence (energy/area) required to obtain a given resolution from (1) an analytical model, giving the count rate at the maximum scattering angle for a model protein, (2) explicit simulation of diffraction patterns for a GroEL-GroES protein complex, and (3) the frequency cut off of the transfer function following iterative solution of the phase problem, and reconstruction of an electron density ...
2007-01-01
Disposal of De-ionizer Vessels Highly Contaminated with 14Carbon at SRS
International Nuclear Information System (INIS)
At the Savannah River Site (SRS), nuclear production reactors used de-ionizers to control the chemistry of the reactor moderator during their operation to produce nuclear materials primarily for the weapons program. These de-ionizers were removed from the reactors and stored as a legacy waste with no path to disposal due to the relatively high 14C contamination (i.e., on the order of 20 curies per de-ionizer for 48-50 de-ionizers) and the low disposal limit of 4.2 Ci previously established for the Intermediate Level Vault (ILV). The ILV is considered most appropriate facility within which to dispose these items due to the method of solidifying waste items with cementitious material inside concrete vaults. In previous analyses the 14C ILV disposal limit was established at 4.2 Ci resulting from the use of a very conservative method to analyze the dose received from atmospheric releases of gaseous 14C. This investigation implemented a more rigorous evaluation of the ...
2008-01-01
Photocatalytic activities of AgSbO3 under visible light irradiation
British Library Electronic Table of Contents (United Kingdom)
A novel visible light sensitive photocatalyst, AgSbO3 was prepared by a conventional solid-state reaction method. This oxide belonging to a cubic-pyrochlore structure can absorb visible light with wavelength up to about 480nm. From the band structure calculation, we found that the top of the valence band consists of the hybridized Ag 4d and O 2p orbitals and the bottom of the conduction band mainly consists of the Ag 5s and the Sb 5s orbitals. Photocatalytic activities were evaluated using O2 evolution from an aqueous silver nitrate solution and decomposition of gaseous 2-propanol under visible light irradiation. We found that AgSbO3 shows a higher O2 evolution activity than WO3 and 2-propanol can be mineralized by the AgSbO3 photocatalysis under visible light irradiation.
2008-01-01
Energy Technology Data Exchange (ETDEWEB)
The procedure was developed to enable STUK (Radiation and Nuclear Safety Authority) to make simplified estimates on off-site consequences based on the existing results of the PSA level 2 calculations done by e.g. power utilities. Method is based on dose calculated from each nuclide group of reactor activity inventory when the same release fraction for each group is assumed. This means that a specific new result from PSA level 2 can be categorised to find out a representative PSA level 3 result for this case. In addition a user interface including the procedure was prepared. Secondly some new insights about consequences based on the releases from PSA level 2 is expected to give better understanding of risks at prevailing increased reactor power levels. In this case only some early health effects and long-term doses were estimated without full-scope PSA level 3 approach. (orig.)
2000-07-01
Quantitative assessment of mineral content in metacarpal bone with Fuji computed radiography
Energy Technology Data Exchange (ETDEWEB)
A new microdensitometry method for quantitative assessment of bone mineral content using Fuji computed radiography (FCR) was developed and the results were compared with those obtained by the conventional film-screen method. Using both methods, X-ray pictures of the 2nd metacarpal bone were taken with a reference aluminum step wedge in nine normal subjects and nine parameters representing the width and density of bone marrow and cortex were calculated in middle of the bone shaft. Interobserver reproducibility assessed for three parameters was significantly higher in the FCR method than the conventional one. The value of {Sigma}GS computed by the FCR method, that is equivalent to the net bone density of the transverse section of the shaft, showed higher correlation with the one obtained by computed tomography in comparison with the conventional method. In our FCR method, moreover, interobserver reproducibility and accuracy was improved by employing automatic ...
1990-05-01
Quantitative assessment of mineral content in metacarpal bone with Fuji computed radiography
International Nuclear Information System (INIS)
A new microdensitometry method for quantitative assessment of bone mineral content using Fuji computed radiography (FCR) was developed and the results were compared with those obtained by the conventional film-screen method. Using both methods, X-ray pictures of the 2nd metacarpal bone were taken with a reference aluminum step wedge in nine normal subjects and nine parameters representing the width and density of bone marrow and cortex were calculated in middle of the bone shaft. Interobserver reproducibility assessed for three parameters was significantly higher in the FCR method than the conventional one. The value of #SIGMA#GS computed by the FCR method, that is equivalent to the net bone density of the transverse section of the shaft, showed higher correlation with the one obtained by computed tomography in comparison with the conventional method. In our FCR method, moreover, interobserver reproducibility and accuracy was improved by employing automatic ...
1990-01-01
Selection of IFE target materials from a safety and environmental perspective
International Nuclear Information System (INIS)
Target materials for inertial fusion energy (IFE) power plant designs might be selected for a wide variety of reasons including wall absorption of driver energy, material opacity, cost and ease of fabrication. While each of these issues are of great importance, target materials should also be selected based upon their safety and environmental (S and E) characteristics. The present work focuses on the recycling, waste management and accident dose characteristics of potential target materials. If target materials are recycled so that the quantity is small, isotopic separation may be economically viable. Therefore, calculations have been completed for all stable isotopes for all elements from lithium to polonium. The results of these calculations are used to identify specific isotopes and elements that are most likely to be offensive as well as those most likely to be acceptable in terms of their S and E characteristics.
2001-05-21
Energy Technology Data Exchange (ETDEWEB)
The Savannah River Site disposes of low-level radioactive waste within on-site engineered disposal facilities. The Savannah River Site must demonstrate that these disposals meet the requirements of DOE Order 435 . 1 through a process known as performance assessment (PA). The objective of this document is to provide the radionuclide -specific data needed for the PA calculations . This work is part of an on-going program to periodically review and update existing PA work as new data becomes available. Revision of the E -Area Low-Level Waste Facility PA is currently underway. The number of radionuclides selected to undergo detailed analysis in the PA is determined by a screening process. The basis of this process is described. Radionuclide-specific data for half-lives, decay modes, daughters, dose conversion factors and groundwater concentration limits are presented with source references and methodologies.
2007-03-20
Prediction of agrochemical residue data on fruit using an informatic system (PARDIS model)
British Library Electronic Table of Contents (United Kingdom)
A `step-by-step' method was used to develop a simplified procedure for calculating pesticide residue levels on fruit at harvest by considering the application of the compound and the relevant routes of loss. The model is applicable to cases where the most important exposure route is by direct spray to the canopy of the crop and where uptake into the plant by the roots can be disregarded. The exposure dose is calculated by considering the proportion of total crop cover represented by the fruits. The loss processes considered are photodegradation, uptake, volatilization and washoff. The outputs of the model were compared with measured residues of pesticides on pear. Analysis of the model fit demonstrates that the model predicted the measured data with a good level of accuracy for four of sev...
2008-01-01
Neutron and gamma-ray penetrations in thick iron
Energy Technology Data Exchange (ETDEWEB)
Measurements of neutron and gamma-ray penetrations in an iron shield were performed up to a 60-cm depth in a tightly coupled source shield configuration with the fast-neutron reactor YAYOI as a source. Rates of neutron reactions and gamma-ray dose rates in the iron shield were obtained using activation foils and thermoluminescent dosimeters. Analyses of the experiments were made by using the DOT-III code with coupled neutron and gamma-ray cross sections from ENDF/B-IV and POPOP4 libraries. To obtain the source condition for the iron shield analyses, the calculated spectrum was adjusted to the measured reaction rates at the reactor shield boundary. The calculated neutron and gamma-ray distributions in the iron shield show fairly good agreement with the experiments. The effect of difference in Bondarenko-type self-shielding factors on the analyses of the iron shield is also shown.
1980-03-01
Convolution/superposition using the Monte Carlo method
International Nuclear Information System (INIS)
The convolution/superposition calculations for radiotherapy dose distributions are traditionally performed by convolving polyenergetic energy deposition kernels with TERMA (total energy released per unit mass) precomputed in each voxel of the irradiated phantom. We propose an alternative method in which the TERMA calculation is replaced by random sampling of photon energy, direction and interaction point. Then, a direction is randomly sampled from the angular distribution of the monoenergetic kernel corresponding to the photon energy. The kernel ray is propagated across the phantom, and energy is deposited in each voxel traversed. An important advantage of the explicit sampling of energy is that spectral changes with depth are automatically accounted for. No spectral or kernel hardening corrections are needed. Furthermore, the continuous sampling of photon direction allows us to model sharp changes in fluence, such as those ...
2003-07-21
International Nuclear Information System (INIS)
For a given linac design, the dosimetric characteristics of a photon beam are determined uniquely by the energy and radial distributions of the electron beam striking the x-ray target. However, in the usual commissioning of a beam from measured data, a large number of variables can be independently tuned, making it difficult to derive a unique and self-consistent beam model. For example, the measured dosimetric penumbra in water may be attributed in various proportions to the lateral secondary electron range, the focal spot size and the transmission through the tips of a non-divergent collimator; the head-scatter component in the tails of the transverse profiles may not be easy to resolve from phantom scatter and head leakage; and the head-scatter tails corresponding to a certain extra-focal source model may not agree self-consistently with in-air output factors measured on the central axis. To reduce the number of adjustable variables in beam modelling, we replace the focal and ...
2005-09-07
Energy Technology Data Exchange (ETDEWEB)
The aetiology of childhood leukaemia remains generally unknown, although exposure to moderate and high levels of ionising radiation, such as was experienced during the atomic bombings of Japan or from radiotherapy, is an established cause. Risk models based primarily upon studies of the Japanese A-bomb survivors imply that low-level exposure to ionising radiation, including to ubiquitous natural background radiation, also raises the risk of childhood leukaemia. In a recent paper (Wakeford et al 2009 Leukaemia 23 770-6) we estimated the proportion of childhood leukaemia incidence in Great Britain attributable to natural background radiation to be about 20%. In this paper we employ the two sets of published leukaemia risk models used previously, but use recently published revised estimates of natural background radiation doses received by the red bone marrow of British children to update the previous results. Using the newer dosimetry we ...
2009-12-01
The helical tomotherapy thread effect
International Nuclear Information System (INIS)
Inherent to helical tomotherapy is a dose variation pattern that manifests as a 'ripple' (peak-to-trough relative to the average). This ripple is the result of helical beam junctioning, completely unique to helical tomotherapy. Pitch is defined as in helical CT, the couch travel distance for a complete gantry rotation relative to the axial beam width at the axis of rotation. Without scattering or beam divergence, an analytical posing of the problem as a simple integral predicts minima near a pitch of 1/n where n is an integer. A convolution-superposition dose calculator (TomoTherapy, Inc.) included all the physics needed to explore the ripple magnitude versus pitch and beam width. The results of the dose calculator and some benchmark measurements demonstrate that the ripple has sharp minima near p=0.86(1/n). The 0.86 factor is empirical and caused by a beam junctioning of the ...
2005-05-01
Biologically effective dose in total-body irradiation and hematopoietic stem cell transplantation
Energy Technology Data Exchange (ETDEWEB)
Background and Purpose: Total-body irradiation (TBI) is an important part of the conditioning regimen for hematopoietic stem cell transplantation (HSCT) in patients with hematologic malignancies. The results after treatment with various TBI regimes were compared, and dose-effect relationships for the endpoints relapse incidence, disease-free survival, treatment-related mortality, and overall survival were derived. The aim was to define requirements for an optimal treatment schedule with respect to leukemic cell kill and late normal-tissue morbidity. Material and Methods: A literature search was performed. Three randomized studies, four studies comparing results of two or three TBI regimens, and nine reports with results of one specific TBI regimen were identified. Biologically effective doses (BEDs) were calculated. The results of the randomized studies and the studies comparing results of two or three TBI regimens were ...
2006-11-15
Biologically effective dose in total-body irradiation and hematopoietic stem cell transplantation
International Nuclear Information System (INIS)
Background and Purpose: Total-body irradiation (TBI) is an important part of the conditioning regimen for hematopoietic stem cell transplantation (HSCT) in patients with hematologic malignancies. The results after treatment with various TBI regimes were compared, and dose-effect relationships for the endpoints relapse incidence, disease-free survival, treatment-related mortality, and overall survival were derived. The aim was to define requirements for an optimal treatment schedule with respect to leukemic cell kill and late normal-tissue morbidity. Material and Methods: A literature search was performed. Three randomized studies, four studies comparing results of two or three TBI regimens, and nine reports with results of one specific TBI regimen were identified. Biologically effective doses (BEDs) were calculated. The results of the randomized studies and the studies comparing results of two or three TBI regimens were ...
2006-11-01
Energy Technology Data Exchange (ETDEWEB)
The radionuclide characteristics of light-water-reactor (LWR) spent fuel play key roles in the design and licensing activities for radioactive waste transportation systems, interim storage facilities, and the final repository site. Several areas of analysis require detailed information concerning the time-dependent behavior of radioactive nuclides including (1) neutron/gamma-ray sources for shielding studies, (2) fissile/absorber concentrations for criticality safety determinations, (3) residual decay heat predictions for thermal considerations, and (4) curie and/or radiological toxicity levels for materials assumed to be released into the ground/environment after long periods of time. The crucial nature of the radionuclide predictions over both short and long periods of time has resulted in an increased emphasis on thorough validation for radionuclide generation/depletion codes. Current radionuclide generation/depletion codes have the capability to follow the ...
1995-01-01
Tritium bioassay and dosimetry at a CANDU reactors
Energy Technology Data Exchange (ETDEWEB)
Tritium dose management is an important aspect of the radiation protection program at CANDU type reactor sites. This paper describes the bioassay and dosimetry of tritium at CANDU reactor sites, especially for Wolsung Nuclear Power Plant. It presents a compilation of information drawn from published papers, technical reports, international and national guidelines as well as practical experience both in Korean and Canadian CANDU Nuclear Power Plants. The implementation of this program would provide a technical basis for calculations and records should be of acceptable quality and should meet overall radiation protection program objectives.
1996-07-01
The role of brachytherapy in radiation and isotopes centre of Khartoum (RICK)
International Nuclear Information System (INIS)
As there are many efforts devoted in order to manage the cancer, here the researcher handle one of these efforts that play a major part in treating the cancer internationally, it is a brachytherapy system. Brachytherapy was carried out mostly with radium sources, but recently some artificial sources are incorporated in this mode of treatment such as Cs-137, Ir-192, Au-198, P-32, Sr-90 and I-125. The research cover history of brachytherapy and radioactive sources used in, techniques of implementation, radiation protection and methods of brachytherapy dose calculation, as well as brachytherapy in radiation and isotopes centre in Khartoum.
Radiotherapeutic methods for Ewing's sarcoma of the long tubular bones in children
International Nuclear Information System (INIS)
Radiotherapeutic results of the Ewing sarcoma of the long tubular bones in 140 pediatric patients aged 3-16 are analyzed with the respect to different methods of irradiation. Three-field irradiation, the fields being located at 120 deg to one another with daily irradiation of all three fields at a focal dose of 2 Gy, was found superior in treatment of primary neoplasm. It is stressed that the disease termination mainly depends on the efficiency of primary neoplasm treatment, as the neoplasm reccurence generally is followed by metastases. Radiation load is calculated for maximal irradiation area of soft tissues in children.
Preparation of wood-polymer composites by using ionizing radiation
International Nuclear Information System (INIS)
Radiation-initiated polymerization of styrene and acrylic acid in poplar wood were investigated for the preparation of wood-polymer composites. The direct irradiation method was applied to the monomer adsorbed poplar wood specimens. 8000 Ci "6"0Co source at a dose rate of about 0.4 Mrad/h was used. Furthermore the effects of carbon tetrachloride, methanol, dioxane and acrylonitrile on styrene polymerization were investigated and the reaction rates were calculated for each case. The influence of CCl_4 (10%) on acrylic acid polymerization in poplar wood was also determined. (author).
1982-05-01
FFTF shield and gamma ray measurements
Energy Technology Data Exchange (ETDEWEB)
Shield measurements and four cycles of operating experience have shown the design and construction of radiation shields for the Fast Flux Test Facility (FFTF) reactor and plant to be satisfactory. A number of minor shield deficiencies were found and corrected. Most of these were associated with interfaces between components, each of which was satisfactory by itself. Preliminary evaluation of the shield measurements indicates satisfactory agreement with design calculations. Operator doses to date have been quite small, especially when compared to light water reactor experience.
1984-08-01
... energy absorption characteristics of composite sandwich panels, thermoplastic energy-absorbing subfloor structures, and shoulder belt pre- tensioners. ...
Random motion of a particle emitting and absorbing tachyons
International Nuclear Information System (INIS)
Random motion of a particle, emitting and absorbing tachyons, is investigated. It is shown that if bradyon is in equilibrium with neutral gas, i.e. it absorbs and emits tachyons, which do not have any charges, tha particle with each absorption-emittance of a tachyon changes its energy and momentum, never varying its own mass, and as a result it moves like a brownian particle. Thus, bradyon, interacting with tachyon gas, increases its momentum continuously in agreement with the Einstein-Fokker-Planck type equation.
Energy Technology Data Exchange (ETDEWEB)
The principal mathematical tools frequently available for calculations in Nuclear Engineering, including coupled neutron-gamma radiations shielding problems, involve the full Transport Theory or the Monte Carlo techniques. The Multigroup Albedo Method applied to shieldings is characterized by following the radiations through distinct layers of materials, allowing the determination of the neutron and gamma fractions reflected from, transmitted through and absorbed in the irradiated media when a neutronic stream hits the first layer of material, independently of flux calculations. Then, the method is a complementary tool of great didactic value due to its clarity and simplicity in solving neutron and/or gamma shielding problems. The outstanding results achieved in previous works motivated the elaboration and the development of this study that is presented in this dissertation. The radiation balance resulting from the ...
2002-07-01
Analysis of coupled neutron-gamma radiations, applied to shieldings in multigroup albedo method
International Nuclear Information System (INIS)
The principal mathematical tools frequently available for calculations in Nuclear Engineering, including coupled neutron-gamma radiations shielding problems, involve the full Transport Theory or the Monte Carlo techniques. The Multigroup Albedo Method applied to shieldings is characterized by following the radiations through distinct layers of materials, allowing the determination of the neutron and gamma fractions reflected from, transmitted through and absorbed in the irradiated media when a neutronic stream hits the first layer of material, independently of flux calculations. Then, the method is a complementary tool of great didactic value due to its clarity and simplicity in solving neutron and/or gamma shielding problems. The outstanding results achieved in previous works motivated the elaboration and the development of this study that is presented in this dissertation. The radiation balance resulting from the ...
2002-01-01
The effect of a metal hip prosthesis on the radiation dose in therapeutic photon beam irradiations
International Nuclear Information System (INIS)
Prostate and cervical cancer patients are often treated with external X-ray beams of bi-lateral incidence. Such treatment may incur some dose effect that cannot be predicted precisely in commercial treatment planning systems (TPS) for patients having undergone total hip replacement. This study performs a Monte Carlo (MC) simulation and an analytical calculation (convolution superposition algorithm which is implemented in ADAC TPS) of a 6 MV, 5x5 cm"2 X-ray beam incident into water with the existence of hip prosthesis, e.g. Ti6Al4V and CoCrMo alloy. The results indicate that ADAC TPS cannot precisely account for the scatter and backscatter radiation that a metal hip prosthesis causes. For percent depth dose (PDD) curves, the maximum underdosage of ADAC TPS up to 5 mm above the interface between dense material and water is 5%, 20% and 27% for PDD_B_o_n_e, PDD_T_i and PDD_C_o, respectively. The dose ...
2002-07-01
International Nuclear Information System (INIS)
The effects of extended source-to-surface distance (SSD) on the electron beam dose profiles were evaluated for various electron beam energies - 6, 9, 12, 15 and 20 MeV - and the accuracy of various output correction methods was analysed on a Mitsubishi linear accelerator using a radiation field analyser (RFA). The dose fall-off region of the central axis depth-dose curves was nearly independent for SSDs up to 120 cm where as in the build-up region, a marginal reduction of surface dose was observed, particularly for lower energies and for smaller field sizes. Effective SSDs and virtual source distances were evaluated for field sizes ranging from 5x5 to 15x15 cm"2 for various energies. Curve fitting was done with the measured outputs with various equations and coefficients were evaluated. The accuracy of the derived output correction factors by effective SSD, virtual source distance and curve-fit methods ...
2002-09-21
A review of 4 norm industries in Ireland
Energy Technology Data Exchange (ETDEWEB)
Full text: This presentation will review the progress achieved so far by the Irish national regulatory agency, the Radiological Protection Institut e of Ireland (R.P.I.I.) in the investigation of work activities where the presence of natural radiation sources (NORM) could lead to a significant increase in exposure to workers or members of the public which cannot be disregarded from the radiation protection point of view. Since the coming into force in Ma y 2000 of the Radiological Protection Act, 1991 (Ionising Radiation) Order, 2000 (S.I. No. 125 of 2000) which implements the Eu B.S.S. Directive 96/29/EURATOM, four major NORM industries currently active in Ireland have been investigated. According to the literature, they are all considered liable to involve work practices resulting in exposure to NORM. They include: the gas extraction and production industry, the peat- and coal-firing power generation industry and the bauxite/alumina refining industry. For the gas industry, monitoring ...
2006-07-01
Radiation receiver. Strahlungsempfaenger
Energy Technology Data Exchange (ETDEWEB)
The purpose of the invention is to improve a radiation receiver, consisting of a hollow body with an opening for the entry of radiation and a ceramic absorber situated in the hollow body, which absorbs the radiation energy entering through the opening, and emits it as thermal radiation to a heat medium, so that a higher efficiency can be achieved. According to the invention, the problem is solved by the fact that the absorber consists of ceramic material on the side towards the solar radiation, which has a low emission value and a high absorption value, and that the side of the absorber towards the heat medium has ceramic material of high emission value and low absorption value. This ensures that reradiation is prevented near the opening of the hollow body, and that the solar energy entering is largely absorbed in the hollow body.
1981-10-01
International Nuclear Information System (INIS)
An extensive set of benchmark measurement of PDDs and beam profiles was performed in a heterogeneous layer phantom, including a lung equivalent heterogeneity, by means of several detectors and compared against the predicted dose values by different calculation algorithms in two treatment planning systems. PDDs were measured with TLDs, plane parallel and cylindrical ionization chambers and beam profiles with films. Additionally, Monte Carlo simulations by meansof the PENELOPE code were performed. Four different field sizes (10x10, 5x5, 2x2, and1x1 cm"2) and two lung equivalent materials (CIRS, #rho#_e"w=0.195 and St. Bartholomew Hospital, London, #rho#_e"w=0.244-0.322) were studied. The performance of four correction-based algorithms and one based on convolution-superposition was analyzed. The correction-based algorithms were the Batho, the Modified Batho, and the Equivalent TAR implemented in the Cadplan (Varian) treatment planning system and ...
2004-10-01
Application of dose factors for decay chains
International Nuclear Information System (INIS)
... dose rates inhalation iodine 134 krypton 88 nuclear decay quality factor
National Emission Standards for Hazardous Air Pollutants submittal -- 1994
Energy Technology Data Exchange (ETDEWEB)
This report focuses on air quality at the Nevada Test Site (NTS) for 1994. A general description of the effluent sources are presented. Each potential source of NTS emissions was characterized by one of the following: (1) by monitoring methods and procedures previously developed at NTS; (2) by a yearly radionuclide inventory of the source, assuming that volatile radionuclides are released to the environment; (3) by the measurement of tritiated water concentration in liquid effluents discharged to containment ponds and assuming all the effluent evaporates over the course of the year to become an air emission; or (4) by using a combination of environmental measurements and CAP88-PC to calculate emissions. Appendices A through J describe the methods used to determine the emissions from the sources. These National Emission Standards for Hazardous Air Pollutants (NESHAP) emissions are very conservative, are used to calculate the effective ...
1995-06-01
Energy Technology Data Exchange (ETDEWEB)
In 1959, the Test Manager's Committee to Establish Fallout Doses calculated estimated external gamma exposure at populated locations based upon measurements of external gamma-exposure rate. Using these calculations and estimates of population, we have tabulated the collective estimated external gamma exposures for communities within established fallout patterns. The total collective estimated external gamma exposure is 85,000 person-R. The greatest collective exposures occurred in three general areas: Saint George, Utah; Ely, Nevada; and Las Vegas, Nevada. Three events, HARRY (May 19, 1953), BEE (March 22, 1955), and SMOKY (August 31, 1957), accounted for over half of the total collective estimated external gamma exposure. The bases of the calculational models for external gamma exposure of ''infinite exposure,'' ''estimated ...
1985-12-01
International Nuclear Information System (INIS)
A new leaf-sequencing approach has been developed that is designed to reduce the number of required beam segments for step-and-shoot intensity modulated radiation therapy (IMRT). This approach to leaf sequencing is called continuous-intensity-map-optimization (CIMO). Using a simulated annealing algorithm, CIMO seeks to minimize differences between the optimized and sequenced intensity maps. Two distinguishing features of the CIMO algorithm are (1) CIMO does not require that each optimized intensity map be clustered into discrete levels and (2) CIMO is not rule-based but rather simultaneously optimizes both the aperture shapes and weights. To test the CIMO algorithm, ten IMRT patient cases were selected (four head-and-neck, two pancreas, two prostate, one brain, and one pelvis). For each case, the optimized intensity maps were extracted from the Pinnacle"3 treatment planning system. The CIMO algorithm was applied, and the optimized aperture shapes and weights were loaded back into ...
2006-04-01
An integrated Tomographic Gamma Scanning system for non-destructive assay of radioactive waste
Energy Technology Data Exchange (ETDEWEB)
The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm{sup -3} or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant applications. Many of the design features and the end application itself set these TGS ...
2007-08-21
An integrated Tomographic Gamma Scanning system for non-destructive assay of radioactive waste
International Nuclear Information System (INIS)
The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm"-"3 or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant applications. Many of the design features and the end application itself set these TGS systems ...
2007-08-21
FFTF [Fast Flux Test Facility] Fission Gas Monitor Computer System
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF) is a liquid-metal-cooled, fast neutron test reactor located on the Hanford Site. A dual computer system has been developed to monitor the reactor cover gas to detect and characterize any fuel or test pin fission gas releases. The system acquires gamma spectra data, identifies isotopes, calculates specific isotope and overall cover gas activity, presents control room alarms and displays, and records and prints data and analysis reports. The Fission Gas Monitor System (FGMS) integrates commercially available hardware and software, providing a reliable and easily maintained system. The design provides extensive automation of previous manual operations, reducing the need for operator training and minimizing the potential for operator error. The dual nature of the system allows either system A or B to be taken out of service for periodic tests or maintenance without interrupting the overall system performance. A control room color ...
Project SAFE. Update of the SFR-1 safety assessment. Phase 1. Appendix A1: Inventory
Energy Technology Data Exchange (ETDEWEB)
One of the aims in the safety assessment of SFR-1 is to estimate the release to the environment. In order to make these calculations there is a need to describe the inventory in greater detail. The new computerised database of waste in SFR-1 gives a good possibility to achieve this. The aim for project SAFE is to make both conservative and realistic radionuclide transport calculations. To achieve this goal there must be two inventories. The conservative inventory is the inventory used in the design of the repository, which in most parts is identical with the limits in the licence for SFR-1. There is a great interest to have good estimates of the volumes of the different waste types. A thorough prognosis should be made in 1999, but until then the latest one from 1995 could be used in the calculations. The total (actual) inventory of nuclides is calculated from the measurements of the easy-to-measure ...
1998-10-01
Radial dose distribution of 6.0 MeV/n #alpha#-particle in water
International Nuclear Information System (INIS)
For the study of radiation biology and its application to radiotherapy, the double differential cross section of electron emission from water vapor induced by 6.0 MeV alpha particle beam is measured. The energy spectra of electrons ranging 7- 10000 eV are detected by the electrostatic analyzer and micro channel plate. The measurements are made at angles between 20 and 160 degrees. With use of this data set, the radial dose distribution in water is calculated by using KURBUC code. It is the Monte Carlo type code of the electron transport process, where the track of the electron is simulated through each individual interactions including elastic scattering, ionization cross section and total excitation cross section in case that electrons with certain energy are put in the liquid-density water. In order to understand the effect of radiation when the particle flux is injected in the human body like radiotherapy using accelerator beam, the ...
2003-08-17
Postremediation dose assessment for the former Alba Craft Laboratory site, Oxford, Ohio
Energy Technology Data Exchange (ETDEWEB)
Potential maximum radiation dose rates were calculated for the former Alba Craft Laboratory site in Oxford, Ohio, which was involved in machining of uranium metal in the 1950s for the U.S. atomic energy program. The site is not currently being used. The residual radioactive material guidelines (RESRAD) computer code, which implements the methodology described in the US Department of Energy`s (DOE`s) manual for establishing residual radioactive material guidelines, was sued in this evaluation. Three potential land use scenarios were considered for the former Alba Craft site; the scenarios vary with regard to the type of site use, time spent at the site by the exposed individual, and sources of food consumed. Scenario A (a possible land use scenario) assumed industrial use of the site; Scenario B (a likely future land use scenario) assumed residential use of the site; and Scenario C (a possible but unlikely land use scenario) assumed the presence ...
1996-04-01
Nuclear radiation detectors on II-VI compounds
International Nuclear Information System (INIS)
Nuclear radiation detectors in integral execution were produced by successive epitaxial growth from vapor phase of Zn Te and Cd Se thin layers onto scintillating Zn Se (Te) crystals. The irradiation of combined Zn Se (Te) - Zn Te - Cd Se detectors by Cu_K_a X-rays leads to the appearance of photoreceiver e.m.f., which tends to saturation with the increase of X-ray radiation dose reaching the value of 0.34-0.40 V at 200 R/min. The short circuit current dependence of irradiation dose power is linear. The matching factor for detectors with Zn Te-Cd Se photoreceivers with different doping levels is 0.68-0.92. The absolute monochromatic sensitivity is 0.32-0.35 m A/m W at a quantum efficiency 0.58-0.61 and a time constant 2 x 10"-"4 s. The calculated dose sensitivity for Zn Se(Te)-Zn Te-Cd Se combined detectors at the irradiation with X-rays having effective energy 8.86 keV gives the value 3.9 x 10"-"7 ...
1993-10-13
Energy Technology Data Exchange (ETDEWEB)
Our objective was to evaluate the feasibility of ultra-low-dose scanning for multislice CT colonography in the detection of colorectal lesions. Twenty-seven patients (14 men, 13 women) with clinical indication for conventional colonoscopy were recruited. Multislice spiral CT (Somatom Plus 4 Volume Zoom, Siemens, Germany) examinations were performed after standard oral colonoscopic preparation and colonic distension with room air. Images were acquired using 2.5-mm collimation, 3.0-mm slice thickness, standard reconstruction kernel, 140 kVp, and 10 mAs. Supine and prone acquisitions were obtained in all patients. Images were analyzed on a workstation by two gastrointestinal radiologists. Conventional colonoscopy was performed on the same day in all patients and represented the standard of reference. Total radiation exposure was also calculated. All colorectal cancers were correctly identified at CT colonography (9 of 9, sensitivity 100%). The CT ...
2003-06-01
Development of an irradiation system for a small size continuous run multipurpose gamma irradiator
International Nuclear Information System (INIS)
The Radiation Technology Center from IPEN-CNEN/SP, Brazil, developed a revolutionary design and national technology, a small-sized continuous run and multipurpose industrial gamma irradiator, to be used as a demonstration facility for manufacturers and contract service companies, which need economical and logistical in-house irradiation system alternatives. Also, to be useful for supporting the local scientific community on development of products and process using gamma radiation, assisting the traditional and potential users on process validation, training and qualification of operators and radioprotection officers. The developed technology for this facility consists of a continuous tote box transport system, comprising a single concrete vault, where the automated transport system of products inside and outside of the irradiator utilizes a rotating door, integrated with the shielding, avoiding the traditional maze configuration. Covering 76 m"2 of floor area, the irradiator design is ...
Depuration of shellfish by irradiation: Final technical report, October 1, 1987--March 31, 1989
International Nuclear Information System (INIS)
Studies by the University of Lowell Radiation Laboratory and the US National Marine Fisheries Service N.E. Laboratory in Gloucester, MA on softshelled clams (Mya arenaria) demonstrated the effectiveness of low to medium doses of Cobalt 60 source gamma irradiation in the inactivation of Escherichia coli, Salmonella typhimurium, Staphylococcus aureus and Streptococcus faecalis. Post-irradiation survival and organoleptic studies when extended to hardshelled clams (Mercinaria mercenaria) and American oysters (Crassostrea virginica) showed no significant decline in consumer qualities or 6 day post irradiation survival in oysters at doses of up to 3.0 kGy. The capacities of the American oyster to sustain relatively high doses of gamma irradiation were demonstrated by 6 day post-exposure survivorship values of greater than 90% for samples receiving 3.0, 5.0 and 7.0 kGy. Initial studies of inactivation of Polio I virus and a simian ...
Energy Technology Data Exchange (ETDEWEB)
To determine a suitable combination of X-ray filter and tube kilovoltage for Fuji Computed Radiography (FCR), provide better detection of pulmonary nodules, and reduce patient exposure, we compared observer performance with different X-ray filters and tube voltages. Radiographs were obtained with a copper filter backed by aluminium, with a tungsten filter backed by yttrium and aluminium, and with a lead filter backed by yttrium and aluminium, at both 100 kVp and 135 kVp. Observer performance in detecting simulated lung nodules, which were placed on the posterior aspect of a chest phantom, was compared using receiver operating characteristic (ROC) techniques for each combination of the X-ray filter and tube voltage. The results of the study indicated that (1) nodule detection was superior for the images obtained with 135 kVq as compared with 100 kVp; (2) approximately equal detection rates were obtained for the three X-ray filter sets, although results with the tungsten filter were ...
1994-10-01
International Nuclear Information System (INIS)
To determine a suitable combination of X-ray filter and tube kilovoltage for Fuji Computed Radiography (FCR), provide better detection of pulmonary nodules, and reduce patient exposure, we compared observer performance with different X-ray filters and tube voltages. Radiographs were obtained with a copper filter backed by aluminium, with a tungsten filter backed by yttrium and aluminium, and with a lead filter backed by yttrium and aluminium, at both 100 kVp and 135 kVp. Observer performance in detecting simulated lung nodules, which were placed on the posterior aspect of a chest phantom, was compared using receiver operating characteristic (ROC) techniques for each combination of the X-ray filter and tube voltage. The results of the study indicated that 1) nodule detection was superior for the images obtained with 135 kVq as compared with 100 kVp; 2) approximately equal detection rates were obtained for the three X-ray filter sets, although results with the tungsten filter were ...
1994-01-01
Self-expandable stent loaded with {sup 125}I seeds: Feasibility and safety in a rabbit model
Energy Technology Data Exchange (ETDEWEB)
Objective: To evaluate technical feasibility and acute and subacute radiotolerance of a self-expandable stent loaded with {sup 125}I seeds in the rabbit esophagus. Methods: A self-expandable stent designed for esophageal application was made of 0.16 mm nitinol wire and loaded with {sup 125}I seeds (CIAE-6711). Twenty-seven stents with three different radioactive dosages (n = 9 in each dosage group) were implanted in the esophagus of healthy rabbits, while nine stents alone were used as controls. The stents were perorally deployed into the esophagus under fluoroscopic guidance. Radiological follow-up included plain chest film, CT scan, and barium esophagography which were undertaken in all rabbits of each group at 2, 4, and 8 weeks, respectively, which were correlated to histopathological findings. The stented esophageal segments along with their adjacent tissues were harvested for histopathological examinations. Results: The stent was successfully deployed into the targeted esophageal ...
2007-02-15
Radioactive lead studies in the human
International Nuclear Information System (INIS)
The differing susceptibility of individuals to the toxic effects of chronic lead exposure has never been fully understood. As the major intake of lead in the human is from food and beverages, any variation between individuals of the quantity of lead absorbed from the gut, and of the distribution and excretion of this lead, may account for the differences in individual susceptibility. The food and beverages themselves may have an influence, and to investigate their effects on absorption, distribution and excretion of lead, experiments were performed on normal subjects using a short lived radionuclide of lead, "2"0"3Pb, and instruments generally available in Nuclear Medicine. Lead absorption between different individuals showed a wide variation when "2"0"3Pb was taken as a single dose between meals. Minerals were found to be mainly responsible for affecting absorption when one subject ingested "2"0"3Pb in control meals from which one dietary ...
International Nuclear Information System (INIS)
The mechanism of lead transport is presented, and especially the particular similarities or dissimilarities between lead and calcium in this process. The absorption of these metals was determined cockerels, raised on a commercial diet or on a specified diet, using in vivo ligated loop procedure. The dose administered into the loop contained 0.5 #mu#Ci "2"0"3Pb (and/or 0.1 #mu#Ci "4"7Ca), and 0.01 mM lead acetate (and/or mM CaCl_2) in 0.5 ml 0.15 M NaCl,pH 6.5. It was shown that lead is rapidly taken up by the mucosal tissue, and slowly transferred into the body, whereas less calcium is retained by the tissue and the transfer of calcium is many times as effective as that for lead. They appear to respond in a similar manner to a low calcium intake and vitamin D treatment. Increasing luminal stable lead concentration significantly reduced the percentage of radiolead significantly reduced the percentage of radiolead absorbed, but did not affect the ...
Energy Technology Data Exchange (ETDEWEB)
Two neutron emesis experiments were conducted at the Armed Forces Radiobiology Research Institute (AFRRI). In both experiments (described as Phase I and Phase II) the radiation dose required to cause emesis in 50% of subjects (ED50) was determined for both neutron reactor and gamma reactor source radiation. Emesis onset, offset and duration times post-exposure are reported. Neutrons were maximized from the reactor by passing the beam through a 15.25 cm (6 in.) thick lead wall to filter out gamma photons. Gamma rays were maximized by thermalizing neutrons in 30.5 cm (12 in.) of water, then absorbing the thermal neutrons in a gadolinium-cadmium shield. In Phase I, 28 dogs were exposed to radiation: 12 were exposed to gamma photons at the rate of 0.69 Gy/min and 16 were exposed to neutrons at 1.2 Gy/min. In Phase II, 58 dogs in 3 groups were exposed to radiation: 19 were exposed in the gamma group at 0.75 Gy/min, 20 were exposed in the undrugged ...
1985-08-01
Effect of vitamin D on the intestinal absorption of 203Pb and 47Ca in chicks
Energy Technology Data Exchange (ETDEWEB)
The transfer of 203Pb and/or 47Ca across the intestinal epithelium of the chick was investigated, with emphasis given to the functional role of cholecalciferol (vitamin D-3). 203Pb, after introduction in the intestinal lumen, is rapidly accumulated by the intestinal tissue, and only a fraction of 203Pb is translocated parenterally (absorbed). Cholecalciferol did not significantly affect the accumulation of 203Pb by intestinal tissue but did accelerate 203Pb movement across the basal-lateral membrane. In contrast, cholecalciferol both decreased 47Ca tissue levels and increased 47Ca absorption. In rachitic chicks, the rate of absorption of 203Pb was greater in the distal than in the proximal segments of the intestine; after cholecalciferol repletion, the degree of absorption in al segments was similar, indicting the order of cholecalciferol effectiveness as duodenum greater than or equal to jejunum greater than ileum. An acute dose of 1,25(OH)2D3 ...
1982-03-01
Effect of vitamin D on the intestinal absorption of /sup 203/Pb and /sup 47/Ca in chicks
Energy Technology Data Exchange (ETDEWEB)
The transfer of /sup 203/Pb and/or /sup 47/Ca across the intestinal epithelium of the chick was investigated, with emphasis given to the functional role of cholecalciferol (vitamin D-3). /sup 203/Pb, after introduction in the intestinal lumen, is rapidly accumulated by the intestinal tissue, and only a fraction of /sup 203/ Pb is translocated parenterally (absorbed). Cholecalciferol did not significantly affect the accumulation of /sup 203/Pb by intestinal tissue but did accelerate /sup 203/Pb movement across the basal-lateral membrane. In contrast, cholecalciferol both decreased /sup 47/Ca tissue levels and increased /sup 47/Ca absorption. In rachitic chicks, the rate of absorption of /sup 203/Pb was greater in the distal than in the proximal segments of the intestine; after cholecalciferol repletion, the degree of absorption in all segments was similar, indicating the order of cholecalciferol effectiveness as duodenum greater than or equal to jejunum > ileum. ...
1982-03-01
Dosimetry audit on the accuracy of 192Ir brachytherapy source strength determinations in Sweden
Energy Technology Data Exchange (ETDEWEB)
The absorbed dose delivered to the patient in brachytherapy is directly proportional to the source strength in terms of the reference air-kerma rate (RAKR). Verification of this quantity by the hospitals is widely recognized as an important part of a quality assurance program. An external audit was performed on behalf of the Secondary Standard Dosimetry Laboratory at the Swedish Radiation Protection Authority (SSI). The aim was to investigate how accurately the source-strength in 192Ir brachytherapy is determined at Swedish hospitals. The SSI reference well-type ion chamber and calibrated equipment were used to measure the RAKR of an 192Ir source in each of the 14 Swedish afterloading units. Comparisons with values determined by vendors and hospitals were made. Agreement in values of RAKR as determined by SSI, hospitals and vendors were in all cases within the +-3% uncertainty (at a coverage factor of k=2), typically guaranteed by the vendors. ...
2007-11-15
Radioactive iodine absorbing properties of tetrathiafulvalene
Energy Technology Data Exchange (ETDEWEB)
For the purpose of searching some effective absorbents of gaseous radioactive iodine, 16 substances considered as having an affinity for iodine were investigated with regular iodine and /sup 125/I. In a preliminary survey, only tetrathiafulvalene (TTF) was found to have satisfactory absorbing properties comparable to activated charcoal. A further detailed comparison of the properties between TTF and activated charcoal led us to the conclusion that the former has more preferable properties as absorbent of radioactive iodine than the latter in all points studied. The results are summarized as follows: (1) The absorption of iodine on TTF in atmosphere was about twice as much as that on activated charcoal. Desorption of iodine from saturatedly absorbed iodine on TTF was practically negligible except trace amount of initial desorption, while that on activated charcoal was considerable (3%/50h) even in the ...
1989-05-01
The RADionuclide transport, removal, and dose (RADTRAD) code
International Nuclear Information System (INIS)
The RADionuclide Transport, Removal, And Dose (RAD-TRAD) code is designed for U.S. Nuclear Regulatory Commission (USNRC) use to calculate the radiological consequences to the off-site population and to control room operators following a design-basis accident at light water reactor (LWR) power plants. This code utilizes updated reactor accident source terms published in draft NUREG-1465. The code will track the transport of radionuclides as they are released from the reactor pressure vessel, travel through the primary containment and other buildings, and are released to the environment. As the radioactive material is transported through the primary containment and other buildings, credit for several removal mechanisms may be taken, including sprays, suppression pools, overlying pools, filters, and natural deposition. Simple models are available for these different removal mechanisms that use, as input, information about the conditions in the ...
1993-11-14
The RADionuclide Transport, Removal, and Dose (RADTRAD) code
Energy Technology Data Exchange (ETDEWEB)
The RADionuclide Transport, Removal, And Dose (RADTRAD) code is designed for US Nuclear Regulatory Commission (USNRC) use to calculate the radiological consequences to the offsite population and to control room operators following a design-basis accident at Light Water Reactor (LWR) power plants. This code utilizes updated reactor accident source terms published in draft NUREG-1465, ``Accident Source Terms for Light-Water Nuclear Power Plants.`` The code will track the transport of radionuclides as they are released from the reactor pressure vessel, travel through the primary containment and other buildings, and are released to the environment. As the radioactive material is transported through the primary containment and other buildings, credit for several removal mechanisms may be taken including sprays, suppression pools, overlying pools, filters, and natural deposition. Simple models are available for these different removal mechanisms that ...
1993-07-01
SEAFP-2 bounding accident analyses
Energy Technology Data Exchange (ETDEWEB)
Analyses have been performed of the potential consequences to the public of hypothetical loss-of-coolant accidents in conceptual fusion power plant designs. In order to establish upper bounds to the consequences of such events, a case has been studied in which total loss of all active cooling has been assumed, with no remedial intervention for the duration of the accident sequence. The analyses are based on three conceptual power plant designs, two of them similar to those assumed in the earlier safety and environmental assessment of fusion power (SEAFP) study (Raeder et al., 1995), with updating of assumed structural materials. The three models studied provide a broad range of design options. In all cases the decay-heat driven temperature transients are well below the level at which structural melting would begin. Based on conservative assumptions, mobilisation, release and dose calculations show that potential maximum ...
2000-09-01
Radon concentration measurements in mofettes from Harghita and Covasna Counties, Romania
Energy Technology Data Exchange (ETDEWEB)
In the Harghita volcanic range (Romania) there are many occurrences of dry CO{sub 2} emanations, called mofettes. The emanating gas with high carbon dioxide content has a proved curative effect. The gas also contains important quantities of radon. Since the mofettes are used in curative purposes in several illnesses, in most of the cases without medical supervising, has been proposed to determine the radon activity concentration in some of the most frequented mofettes from Romania. The seasonal variations have also been monitored and were calculated the effective doses received by the patients during a cure. The radon activity concentrations' levels above the mofettes indoor air range between 548 and 10 717 Bq/m{sup 3} while within the gas pools' values between 3210 and 32 781 Bq/m{sup 3} have been measured. The effective dose received by the patients during a cure is between 0.0086 and 0.16 mSv. No major ...
2008-12-15
Radon concentration measurements in mofettes from Harghita and Covasna Counties, Romania
International Nuclear Information System (INIS)
In the Harghita volcanic range (Romania) there are many occurrences of dry CO2 emanations, called mofettes. The emanating gas with high carbon dioxide content has a proved curative effect. The gas also contains important quantities of radon. Since the mofettes are used in curative purposes in several illnesses, in most of the cases without medical supervising, has been proposed to determine the radon activity concentration in some of the most frequented mofettes from Romania. The seasonal variations have also been monitored and were calculated the effective doses received by the patients during a cure. The radon activity concentrations' levels above the mofettes indoor air range between 548 and 10 717 Bq/m3 while within the gas pools' values between 3210 and 32 781 Bq/m3 have been measured. The effective dose received by the patients during a cure is between 0.0086 and 0.16 mSv. No major seasonal variations of the radon ...
2008-12-01
Energy Technology Data Exchange (ETDEWEB)
The in situ assembly states of the glucose transport carrier protein in the plasma membrane and in the intracellular (microsomal) storage pool of rat adipocytes were assessed by studying radiation-induced inactivation of the D-glucose-sensitive cytochalasin B binding activities. High energy radiation inactivated the glucose-sensitive cytochalasin B binding of each of these membrane preparations by reducing the total number of the binding sites without affecting the dissociation constant. The reduction in total number of binding sites was analyzed as a function of radiation dose based on target theory, from which a radiation-sensitive mass (target size) was calculated. When the plasma membranes of insulin-treated adipocytes were used, a target size of approximately 58,000 daltons was obtained. For adipocyte microsomal membranes, we obtained target sizes of approximately 112,000 and 109,000 daltons prior to and after insulin treatment, ...
1987-06-15
International Nuclear Information System (INIS)
Dose measurements were performed in several body regions of patients suffering from inflammatory degenerative diseases (humeral epicondylitis, humeroscapular periarthritis, gonarthrosis, axillary hidradenitis, rheumatoid arthritis, coxarthrosis, parotitis). The problem of the radiation induction of neoplasms is predominant concerning somatic as well as genetic risk, discussed by example of the most frequently occurring organ cancer. Compared to the rate of breast cancer in the highly developed industrial states (5,000 to 6,000 cancers/100,000 women) the 'radiation induction' calculated according to a mathematical model of ICRP 26 (1.25 cases of death for breast cancers/100,000 women following for example irradiation of epicondylitis) is behind several powers of ten and not demonstrable. The genetic radiation exposure is also low. Derived from the measurements it is wrong to give up reliable and approved indications of radiotherapy of ...
1983-01-01
OSCAAR calculations for the Iput dose reconstruction scenario of BIOMASS theme 2
Energy Technology Data Exchange (ETDEWEB)
This report presents the results obtained from the application of the accident consequence assessment code, called OSCAAR, developed in Japan Atomic Energy Research Institute to the Iput dose reconstruction scenario of BIOMASS Theme 2 organized by International Atomic Energy Agency. The Iput Scenario deals with {sup 137}Cs contamination of the catchment basin and agricultural area in the Bryansk Region of Russia, which was heavily contaminated after the Chernobyl accident. This exercise was used to test the chronic exposure pathway models in OSCAAR with actual measurements and to identify the most important sources of uncertainly with respect to each part of the assessment. The OSCAAR chronic exposure pathway models almost successfully reconstructed the whole 10-year time course of {sup 137}Cs activity concentrations in most requested types of agricultural products and natural foodstuffs. Modeling of {sup 137}Cs downward migration in soils is, however, still ...
2001-01-01
Natural radionuclides in drinking water in Argentina
International Nuclear Information System (INIS)
As part of the national survey to evaluate natural radioactivity in the environment, concentration levels of natural uranium and "2"2"6Ra have been analyzed in over 300 drinking water samples taken from different locations in Argentina. "2"2"6Ra was determined by "2"2"2Rn emanation and liquid scintillation counting, and natural uranium by a fluorimetric procedure. Values ranging from 0.03 to 24 #mu#g.l"-"1 of natural uranium and from 0.06 to 50 #mu#g.l"-"1, were measured on drinking water samples taken from tap water systems and private wells, respectively. Concentrations up to 15 mBq.l"-"1 and to 22 mBq.l"-"1 of "2"2"6Ra were found in drinking water samples taken from tap water systems and private wells, respectively. These values are compared with the reference values accepted for drinking water. Based on the water intake rate, the age distribution and the measured concentrations, an annual collective effective dose of 1.9 man Sv and an individual committed ...
2000-05-01
International Nuclear Information System (INIS)
This paper presents an overview of issues related to surface water contamination arising from uranium mining activities in the Alligator Rivers Region (ARR) of northern Australia, and a program of research and monitoring that must assess the potential and actual effects on ecosystem and human health. The program of assessing effects on aquatic ecosystems involves a four-tiered approach including the derivation of local water quality guideline trigger values, direct toxicity assessment of mine waters prior to their release, creekside or in situ monitoring for early warning of adverse effects during mine water release, and longer-term monitoring of macroinvertebrate and fish communities. Bioaccumulation in aquatic biota is also assessed, and is an issue of importance not only to ecosystem health, but also to the health of local Aboriginal people. The aquatic animals they consume represent potential sources of radiological dose, and as a result, a major component of ...
2002-12-27
BDTPS The BNCT Treatment Planning System jointly developed at DIMNP and JRC/IE
The idea to couple the Treatment Planning System (TPS) to the information on the real boron distribution in the patient is the main added value of the new methodology set-up at DIMNP of University of Pisa, in collaboration with the JRC of Petten (NL). The methodology has been implemented in the new TPS, called BDTPS (Boron Distribution Treatment Planning System), which takes into account the actual boron distribution in the patient brain, while the standard TPS assumes a uniform boron distribution, absolutely far from the reality. Nowadays, Positron Emission Tomography (PET) is able to provide this in vivo information. The new TPS, based on the Monte Carlo technique, has been validated comparing the main BNCT parameters (thermal flux, boron dose, etc.) as measured during the irradiation of a special heterogeneous boron phantom (HEBOM), ad hoc designed, as calculated by the BDTPS and by the standard TPS SERA. An evident SERA overestimation of ...
2003-01-01
Inhalation Exposure Input Parameters for the Biosphere Model
Energy Technology Data Exchange (ETDEWEB)
This analysis is one of 10 reports that support the Environmental Radiation Model for Yucca Mountain, Nevada (ERMYN) biosphere model. The ''Biosphere Model Report'' (BSC 2004 [DIRS 169460]) describes in detail the conceptual model as well as the mathematical model and its input parameters. This report documents development of input parameters for the biosphere model that are related to atmospheric mass loading and supports the use of the model to develop biosphere dose conversion factors (BDCFs). The biosphere model is one of a series of process models supporting the total system performance assessment (TSPA) for a Yucca Mountain repository. Inhalation Exposure Input Parameters for the Biosphere Model is one of five reports that develop input parameters for the biosphere model. A graphical representation of the documentation hierarchy for the ERMYN is presented in Figure 1-1. This figure shows the interrelationships among the ...
2004-09-10
Carbon dioxide absorption methanol process
Energy Technology Data Exchange (ETDEWEB)
This patent describes a process for removing carbon dioxide from a feed stream of natural gas having at least methane, ethane and heavier. It comprises: first, separating the feed stream in a first separator to form a first stream having substantially all of the propane and heavier hydrocarbons and carbon dioxide and ethane and a second stream, having methane, carbon dioxide and ethane; separating the second stream in a second separator into a stream of carbon dioxide product and a third stream having ethane, methane and carbon dioxide: mixing at least a portion of the third stream with a polar compound; stream after the mixing in an absorber; separating the vapor and liquid of the third stream after the mixing in an absorber; absorbing the remaining unabsorbed carbon dioxide in a lean portion of the polar compound in the absorber, the absorber carbon dioxide and ethane with the ...
1989-08-29
Shock absorber for the leg structure of offshore jack-up rig
Energy Technology Data Exchange (ETDEWEB)
A shock absorber mechanism and method for use on the leg structure of a jack-up offshore drilling rig is described. It is mounted on the bottom of each existing leg of a drilling rig and comprises a pointed piston member which is positioned on the bottom of the leg structure and projects downwards through the can/footing of the rig leg. The piston member is held in place by a resilient tension member which is designed to absorb shock forces during vertical/axial impact of the leg structure when contact is made with the ocean floor. (author).
1992-02-19
Application properties of AB{sub 2}-type hydrogen absorbing alloys
Energy Technology Data Exchange (ETDEWEB)
Use of hydrogen absorbing alloys in various practical applications is always connected with the problem of production of starting alloys. The transition from laboratory samples to small-scale production involves the change of furnace and its operation mode and this has an effect on the preparation method of mixture of starting metal. Also, for some applications such as thermosorption compressors the exact values of thermodynamical parameters of reaction are needed. In the present work we present the results of investigation of series Laves phase hydrogen-absorbing alloys which can be promising in for use in different devices. 1 ref.
1998-07-01
International Nuclear Information System (INIS)
Full text: Thermoluminescence (TL) is a phenomenon of light emission caused by heating a pre-irradiated material. When ionizing radiation hits a TL material, electrons are freed from some atoms and moved in the material, leaving behind 'holes' of positive charge. Subsequently when the TL material is heated, the electrons and the 'holes' re-combine, and release the extra energy in the form of light. The light intensity can be measured, and related to the amount of energy initially absorbed through exposure to the ionizing radiation. In nineteen sixties thermoluminescence dosimeters (TLD) became popular for dosimetric applications in view of their small size, sensitivity and accuracy. Consequently, in early seventies, several countries started adopting of TLD for personnel monitoring. The idea of introducing TLD to replace the then prevalent film dosimeter for personnel monitoring in India was mooted and successfully implemented by Dr. K G Vohra. Limitations of ...
Simplified analytical model to simulate radionuclide release from radioactive waste trenches
International Nuclear Information System (INIS)
In order to evaluate postclosure off-site doses from low-level radioactive waste disposal facilities, a computer code was developed to simulate the radionuclide released from waste form, transport through vadose zone and transport in the saturated zone. This paper describes the methodology used to model these process. The radionuclide released from the waste is calculated using a model based on first order kinetics and the transport through porous media was determined using semi-analytical solution of the mass transport equation, considering the limiting case of unidirectional convective transport with three-dimensional dispersion in an isotropic medium. The results obtained in this work were compared with other codes, showing good agreement. (author)
2010-11-24
Radon concentration measurements in bituminous coal mines
Energy Technology Data Exchange (ETDEWEB)
Radon measurements were carried out in Kozlu, Karadon and Uzulmez underground coal mines of Zonguldak bituminous coal basin in Turkey. Passive-time integrating method, which is the most widely used technique for the measurement of radon concentration in air, was applied by using nuclear etched track detectors (CR-39) in the study area. The radon concentration measurements were performed on a total of 42 points in those three mines. The annual exposure, the annual effective dose and lifetime fatality risk, which are the important parameters for the health of workers, were estimated based on chronic occupational exposure to the radon gas, which is calculated using UNCEAR-2000 and ICRP-65 models. The radon concentrations at several coal production faces are higher than the action level of 1000 Bq m{sup -3}. It is suggested that the ventilation rates should be rearranged to reduce the radon concentration.
2005-07-01
Proteomic analysis of apoptosis induction in human lung cancer cells by recombinant MVL
British Library Electronic Table of Contents (United Kingdom)
Lung cancer is still difficult to treat by current chemotherapeutic procedures. We recently found that MVL, an anti-HIV lectin from blue-green algae Microcystis viridis, also has antitumor activity. The objective of this study was to investigate apoptosis-inducing activity of recombinant MVL (R-MVL) and proteomic changes in A549 cells, and to identify the molecular pathways responsible for the anti-cancer action of R-MVL. We found that R-MVL induces A549 cells apoptosis in a dose-dependent manner by using MTT assay, fluorescent microscope (FM) and flow cytometry (FCM), and the IC50 was calculated to be 24.12??g/ml. Subsequently, 7 altered proteins in R-MVL-treated A549 cells were identified, including upregulated aldehyde dehydrogenase 1 and ?-actin, and five downregulated proteins: heat s...
2011-01-01
International Nuclear Information System (INIS)
Relative doses of 75 MeV/u "1"2C ion beam after passing through different thickness of degraders were measured with the double ionization chamber method. The degrader's thickness equalized to penetration depth of the beam in water and its Bragg curve were obtained. The measured Bragg curve is compared with that calculated based on a model set up by the authors. Meanwhile, the inactivation effect of the ion beam passing through different thickness of degraders on melanoma (B_1_6) cells was measured, and the corresponding survival fraction data for B_1_6 cells were acquired
1998-08-01
FFTF reactor characterization program
International Nuclear Information System (INIS)
Preparations are under way for the initial startup and testing of the Fast Flux Test Facility (FFTF). The FFTF Reactor Characterization Program is that part of the startup test plan that deals with the determination of the neutron, gamma ray and thermal hydraulic characteristics of the reactor. This program encompasses measurements and calculations of: neutron spectra, flux and fluence; gamma-ray spectra, dose and heating; fission rate distributions; capture rate distributions; other reaction rates of interest; fission product yields; and thermal hydraulic data. Measurements of these parameters will be made in the reactor core and reflectors, will extend vertically downward to the vicinity of the core support structure and upward to the top of the sodium pool, and will extend radially outward to include in-vessel fuel storage locations and the cavity between the reactor vessel and the concrete wall.
Evaluation of induced radioactivity in 10 MeV-electron irradiated spices, (1)
International Nuclear Information System (INIS)
Black pepper, white pepper, red pepper, ginger and turmeric were irradiated with 10 MeV electrons from a linear accelerator to a dose of 100 kGy and radioactivity was measured in order to estimate induced radioactivity in the irradiated foods. Induced radioactivity could not be detected significantly by #gamma#-ray spectrometry in the irradiated samples except for spiked samples which contain some photonuclear target nuclides in the list of photonuclear reactions which could produce radioactivity below 10 MeV. From the amount of observed radioactivities of short-lived photonuclear products in the spiked samples and calculation of H_5_0 according to ICRP Publication 30, it was concluded that the induced radioactivity and its biological effects in the 10 MeV electron-irradiated natural samples were negligible in comparison with natural radioactivity from "4"0K contained in the samples. (author).
Effects of ion irradiation on the diffusion of pre-implanted B atoms in crystalline silicon
International Nuclear Information System (INIS)
N-type crystalline Si (100) implanted with 5 keV B ions was subsequently irradiated with MeV Si, O and F ions. The B atom profiles were measured by means of secondary ion mass spectrometer after the treatment of rapid thermal annealing. The results show that the transient enhanced diffusion of B atoms is effectively limited by the post-implantation of high energy ions at high dose. At the same irradiation conditions, it is found that the existence of a SiO_2 layer in the near surface of Si is even more effective in suppressing the transient enhanced diffusion of the doped B atoms. The results are qualitatively discussed in combination with the analyses of RBS/c measurements and calculation of the DICADA code
2001-12-01
Dose consequences from a postulated criticality occurring in a low-level waste disposal facility
Energy Technology Data Exchange (ETDEWEB)
Evaluations were done to determine conditions that could permit nuclear criticality with fissile uranium in low-level waste (LLW) facilities and to estimate potential radiation exposures to personnel if there were such an accident. Simultaneous hydrogeochemical and nuclear criticality studies were done (1) to identity realistic scenarios for uranium migration and concentration increase at LLW disposal facilities, (2) to model groundwater transport of uranium and subsequent concentration via sorption or precipitation, (3) to evaluate the potential for nuclear criticality resulting from potential increases in uranium concentration over disposal limits, and (4) to estimate potential radiation exposures to personnel resulting from criticality consequences. This paper presents the details of the radiation exposure calculations relying on the conditions as determined from the preceding studies detailed in a cited reference.
1997-12-01
International Nuclear Information System (INIS)
In the safety assessment of a high-level radioactive waste (HLW) disposal system, it is required to estimate radiological impacts on future human beings arising from potential radionuclide releases from a deep repository into the surface environment. In order to estimated the impacts, a biosphere model is developed by reasonably assuming radionuclide migration processes in the surface environment and relevant human lifestyles. It is important to modify the present biosphere models or to develop alternative biosphere models applying the biosphere models according to quality and quantify of the information acquired through the siting process for constructing the repository. In this study, alternative biosphere models were developed taking geosphere-biosphere interface of marine environment into account. Moreover, the flux to dose conversion factors calculated by these alternative biosphere models was compared with those by the present basic ...
2001-01-01
Activation analysis of target debris in the national ignition facility
International Nuclear Information System (INIS)
The modeling methods used to compute the neutron-induced activation of target and near-target materials in the NIF facility are presented. A detailed space and energy description of the neutron environment in the different materials is provided. A new capability has been developed to treat in a general way the activation of debris produced in an operational regime of yield and no-yield experiments. First calculations are addressed to analyze the activity of the debris into the target chamber. The contribution of the different components to activity, interior dose rates, and waste disposal rating (WDR) is determined. The importance of the activation coming from primary irradiation in the target, and from secondary irradiation in debris deposited onto the first wall is assessed. Finally, waste hazards of the activated debris when removed out of the chamber and stored are analyzed. (authors)
1999-09-12
#gamma# irradiation of aqueous solutions of human hemoglobin in atmospheres of air and argon
International Nuclear Information System (INIS)
In this study, the degrees of destruction of hemoglobin irradiated in atmospheres of air and argon were compared. Hemoglobin preparations were irradiated in the forms: oxyhemoglobin (HbO_2) deoxyhemoglobin (Hb"2"+) and methemoglobin (MetHb) applying doses of 0.5 to 5 Mrad. The degree of hemoglobin destruction was estimate on the basis of changes in the values of the absorption coefficient at the Soret band, the absorption ratio A_5_0_5/A_5_6_3 determined after conversion of irradiated preparations into MetHb, absorption coefficinets for pyridine hemochromogen obtained from irradiated preparations, and changes in parameters characterizing the hemoglobin oxygenation reaction (log p/sub 1/2/O_2 and the Hill n coefficient). The calculated oxygen enhancement ratios S were generally higher than 1 for the parameters estimated. This indicates that the presence of oxygen during irradiation enhances hemoglobin destruction.
Target stations and beam dumps for the CERN SPS
International Nuclear Information System (INIS)
The design of the absorber blocks for internal and external dumping of the SPS proton beam is discussed. In addition, the external target stations for slow and fast extracted proton beams are described.
1977-03-16
Semiactive field-controllable magneto-rheological fluid dampers for mountain bicycles
This paper presents the development and evaluation of field- controllable, semi-active magneto-rheological fluid (MRF) shock absorbers for a mountain bicycle. Recent trends in the bicycle industry show a movement towards semi-active suspension systems. Two new MRF dampers are designed and tested with the intent of being used on the front and rear suspension of a modern mountain bicycle. The MRF shock absorbers are designed to emulate the performance of the original equipment manufacturer shock absorbers in passive mode. Application of an input electric current to the MRF shock absorber causes a dramatic increase in the damping capacity. Procedures and results are presented for the design and experimental characterization of these MRF dampers.
2000-06-01
Root Cause Analysis, Tank Fire Problem, M1A1 Main Battle ...
... ammunition is stored. Combustible cartridge cases could absorb moisture, swell, and not chamber properly. Additionally, moisture ...
1989-02-01
Power efficiency for very high temperature solar thermal cavity receivers
This invention is an improved solar energy cavity receiver for exposing materials and components to high temperatures. The receiver includes a housing having an internal reflective surface defining a cavity and having an inlet for admitting solar radiation thereto. A photothermal absorber is positioned in the cavity to receive radiation from the inlet. A reflective baffle is positioned between the absorber and the inlet to severely restrict the re-radiation of energy through the inlet. The front surface of the baffle defines a narrow annulus with the internal reflective surface of the housing. The front surface of the baffle is contoured to reflect incoming radiation onto the internal surface of the housing, from which it is reflected through the annulus and onto the front surface of the absorber. The back surface of the baffle intercepts infrared radiation from the front of the absorber. With this ...
1984-01-01
Power efficiency for very high temperature solar thermal cavity receivers
Energy Technology Data Exchange (ETDEWEB)
This invention is an improved solar energy cavity receiver for exposing materials and components to high temperatures. The receiver includes a housing having an internal reflective surface defining a cavity and having an inlet for admitting solar radiation thereto. A photothermal absorber is positioned in the cavity to receive radiation from the inlet. A reflective baffle is positioned between the absorber and the inlet to severely restrict the re-radiation of energy through the inlet. The front surface of the baffle defines a narrow annulus with the internal reflective surface of the housing. The front surface of the baffle is contoured to reflect incoming radiation onto the internal surface of the housing, from which it is reflected through the annulus and onto the front surface of the absorber. The back surface of the baffle intercepts infrared radiation from the front of the absorber. With this ...
1984-10-30
Influence of absorbed hydrogen on the positron lifetime spectra in Pd, Pd-Ag, Pd-Cu
International Nuclear Information System (INIS)
(1 Oct 1979). German Democratic Republic Alekseeva, OK Onishchuk, VA
1979-10-01
Improved power efficiency for very-high-temperature solar-thermal-cavity receivers
Energy Technology Data Exchange (ETDEWEB)
This invention is an improved solar energy cavity receiver for exposing materials and components to high temperatures. The receiver includes a housing having an internal reflective surface defining a cavity and having an inlet for admitting solar radiation thereto. A photothermal absorber is positiond in the cavity to receive radiation from the inlet. A reflective baffle is positioned between the absorber and the inlet to severely restrict the re-radiation of energy through the inlet. The front surface of the baffle defines a narrow annulus with the internal reflective surface of the housing. The front surface of the baffle is contoured to reflect incoming radiation onto the internal surface of the housing, from which it is reflected through the annulus and onto the front surface of the absorber. The back surface of the baffle intercepts radiation from the front of the absorber. With this arrangement, a ...
1982-04-14
British Library Electronic Table of Contents (United Kingdom)
Abstract The characteristics of desulfurization and denitrification with composite absorbent were researched through aqueous absorption experiments. The removal efficiencies of SO2 and NO were up to 100 and 95%, respectively. The composite absorbent included NaClO2 and component M. Existence of component M in the solution could reduce the absorbent cost compared with using sodium chlorite alone. Chlorine dioxide, as main reaction intermediate product, participated in oxidation reaction. The optimal experimental conditions involved NaClO2 concentration of1.13 mmol/L, solution pH of 5.5, molar ratio (M/NaClO2) of 4.1, reaction temperature of 323 K. The optimal solution pH and reaction temperature were both in the required ranges of limestone-gypsum wet flue gas desulfurization (FGD) process....
2011-01-01
Energy absorbers used against impact loading
International Nuclear Information System (INIS)
In the WWER-440 reactor the primary piping consists of six horizontal loops going radially from the pressure vessel, each loop having a horizontal steam generator. In this reactor type the relatively long primary piping with many curved sections requires special attention in order to successfully eliminate the consequences of the design basis accident. Emergency supports are located in appropriate places to restrict the movements of the pipe. Under normal conditions there is a gap of some centimeters between the pipe and a support so that in the pipe can be deformed freely under changing loads. This paper deals with those energy-absorbing structures used at the Loviisa Nuclear Power Plant for protection against impact loading. Places and circumstances where energy-absorbing structures are employed are specified. Development and design of impact absorber elements are discussed and impact tests are described. (Auth.).
1975-09-08
International Nuclear Information System (INIS)
The behaviour of the packaging materials under radiation field has a great importance in radiation processing, because, in most cases, they are finally responsible for the preservation of the beneficent changes achieved in irradiated products. For example, in radiation sterilisation and food irradiation, the packages must preserve the sterilisation, respectively the sanitisation. They must preserve also the physical barrier feature. The radiation effects on plastics were extensively studied in the last decades for nuclear industry and more recently for radiation processing. The two major effects of nuclear radiation on polymeric materials are the degradation and cross-linking. The degradation consists in breaking of macromolecules after interaction with nuclear particles, amplified by the free radicals which persist long periods, especially in crystalline polymers. Oxygen could penetrate the sample and interact with free radicals so that the degradation process continues after the ...
Method of describing dose distributions in computer design of teleradiotherapy
International Nuclear Information System (INIS)
Method for description of X-ray radiation dose distribution based on semiempirical description of dose fields is suggested. At that dose field description parameters can be easily individualized for concrete X-ray device.
Groundwater flow analysis and dose rate estimates from releases to wells at a coastal site
Energy Technology Data Exchange (ETDEWEB)
In the groundwater flow modelling part of this work the effective dilution volume in the well scenario was estimated by means of transient simulations of groundwater flow and transport, which are coupled due to the varying salinity. Both deep, drilled wells and shallow surface wells in the vicinity of the repository were considered. The simulations covered the time period from the present to 1000 years after the present. Conceptually the fractured bedrock consists of planar fracture zones (with a high fracture density and a greater ability to conduct water) and the intact rock (in which the fracture density and the hydraulic conductivity are low). For them the equivalent-continuum model was applied separately. Thus, the fractured bedrock was considered as piecewise homogeneous (except for the depth dependence) and isotropic continuum with representative average characteristics. A generic simulation model for groundwater flow and solute transport was developed on the basis of ...
2000-09-01
Radiation dose in computerized tomography
International Nuclear Information System (INIS)
Dosimetric studies in 80 patients examined with the tomographic device 'Somatom' are reported. The gonad doses are compared to those of conventional radiographic techniques.
Energy Technology Data Exchange (ETDEWEB)
Dose-response studies of the radiosensitivity of spermatogonial stem cells in various epithelial stages after irradiation with graded doses of fission neutrons of 1 MeV mean energy were carried out in the Cpb-N mouse. These studies on the stem cell population in stages IX-XI yielded simple exponential lines characterized by an average D0 value of 0.76 +/- 0.02 Gy. In the subsequent epithelial stages XII-III, a significantly lower D0 value of 0.55 +/- 0.02 Gy was found. In contrast to the curves obtained for stem cells in stages IX-III, the curves obtained in stages IV-VIII indicated the presence of a mixture of radioresistant and radiosensitive stem cells. In stage VII, almost no radioresistant stem cells appeared to be present and a D0 value for the radiosensitive stem cells of 0.22 +/- 0.01 Gy was derived. Previously, data were obtained on the size of colonies (in number of spermatogonia) derived from surviving stem cells. Combining these ...
1986-12-01
International Nuclear Information System (INIS)
The focus of this study is to validate whether the sensitivity of dose distribution following the interface of different media can be used to distinguish between small variations of photon energy spectra in the context of the convolution/superposition algorithm in the polyenergetic implementation (Philips Pinnacle"3, ADAC Laboratories, Milpitas, CA). Calculations were performed in homogeneous water and heterogeneous lung/water phantoms. Spectra were generated, in which the weights of the low-, medium- and high-energy components were adjusted sequentially. The heterogeneity correction factor CF_l_u_n_g, the D_2_0/D_1_0 ratio for homogeneous water and logarithmic derivative in buildup region LD_b_u_i_l_d_u_p were assessed for their relative ability to discriminate between different spectra for various field sizes. In accordance with another study (Charland et al 2004), the superior discrimination ability of the CF_l_u_n_g and LD_b_u_i_l_d_u_p ...
2004-09-21
A campaign of discrete radon concentration measurements in soil of Niska Banja town, Serbia
Energy Technology Data Exchange (ETDEWEB)
The first radon soil gas survey in Serbia, using passive detectors (SSNTD, CR-39), was carried out in June 2005 at field sites in Niska Banja town. The aim of the survey was to identify risk zones characterised by high levels of this radioactive gas. Radon measurements were made at the depth of 50 cm, in the ground according to a systematic grid pattern. Furthermore, at all 48 measurement points, the surface gamma dose rates in the air was also measured at the same locations and soil samples were collected for gamma spectrometric analysis for the radionuclides {sup 226}Ra, {sup 228}Th and {sup 40}K. Radon concentrations were found to range from 1270 to 155000Bqm{sup -3} with an average of 33765Bqm{sup -3} and a median value of 12626Bqm{sup -3}. The geometrical mean value and geometrical standard deviation were calculated as 16160Bqm{sup -3} and 3.5Bqm{sup -3}, respectively. Gamma dose rate varies from 92 to 316nGyh{sup -1}, ...
2007-11-15
A campaign of discrete radon concentration measurements in soil of Niska Banja town, Serbia
International Nuclear Information System (INIS)
The first radon soil gas survey in Serbia, using passive detectors (SSNTD, CR-39), was carried out in June 2005 at field sites in Niska Banja town. The aim of the survey was to identify risk zones characterised by high levels of this radioactive gas. Radon measurements were made at the depth of 50 cm, in the ground according to a systematic grid pattern. Furthermore, at all 48 measurement points, the surface gamma dose rates in the air was also measured at the same locations and soil samples were collected for gamma spectrometric analysis for the radionuclides "2"2"6Ra, "2"2"8Th and "4"0K. Radon concentrations were found to range from 1270 to 155000Bqm"-"3 with an average of 33765Bqm"-"3 and a median value of 12626Bqm"-"3. The geometrical mean value and geometrical standard deviation were calculated as 16160Bqm"-"3 and 3.5Bqm"-"3, respectively. Gamma dose rate varies from 92 to 316nGyh"-"1, with an average of 132nGyh"-"1. ...
2007-11-01
The malignancy significant dose from external beam radiotherapy
International Nuclear Information System (INIS)
In the present study an estimate is made of the malignancy significant dose from external beam radiotherapy in New Zealand utilizing data obtained in a survey conducted in 1975. This survey had been designed to assess genetically significant dose. A weighted effective dose equivalent is derived from the malignancy significant dose for direct comparison with mean per capita effective dose equivalents arising from other sources of radiation. 14 refs., 1 fig., 8 tabs.
1987-01-01
Further means for reducing radiation dose during exposure of the pelvis in infants
International Nuclear Information System (INIS)
A simple dose-saving procedure for the diagnosis of congenital hip dysplasia employing a diaphragm in nearfocus position is presented. Doses to the skin and the gonads were measured with a phantom for the new and other techniques. With optimal techniques the skin dose is smaller than 2 mR and the gonadal doses lie around 0.1 mR for both male and female patients. An estimate of the dose burden from undesired radiation is appended. (orig.).
Methodology for calculating guideline concentrations for safety shot sites
Energy Technology Data Exchange (ETDEWEB)
Residual plutonium (Pu), with trace quantities of depleted uranium (DU) or weapons grade uranium (WU), exists in surficial soils at the Nevada Test Site (NTS), Nellis Air Force Range (NAFR), and the Tonopah Test Range (TTR) as the result of the above-ground testing of nuclear weapons and special experiments involving the detonation of plutonium-bearing devices. The special experiments (referred to as safety shots) involving plutonium-bearing devices were conducted to study the behavior of Pu as it was being explosively compressed; ensure that the accidental detonation of the chemical explosive in a production weapon would not result in criticality; evaluate the ability of personnel to manage large-scale Pu dispersal accidents; and develop criteria for transportation and storage of nuclear weapons. These sites do not pose a health threat to either workers or the general public because they are under active institutional control. The DOE is committed to remediating the safety shot sites ...
1997-06-01
Safety of pipe whip restraints
International Nuclear Information System (INIS)
Pipe whip restraints are used in nuclear power plants in order to limit the consequences of ruptured pipe whip effects and are thus an important part of the plant safety concept. The design of these devices is based on the choice of adequate construction and computational analysis supported by experimental investigation. Pipe whip restraints should, by means of deforming components, be able to absorb the energy of a ruptured pipe accelerated by the fluid reaction force. Since the elastic deformation of the restraint material is not sufficient for this purpose, or would result in excessive anchor loads, pipe whip restraints must generally be designed to work in the plastic range. Two types of restraints are presented in this paper, including the description of their mode of operation, design and computation. A comparison and critical evaluation of the calculation methods presently available are also given. The range of methods covers those ...
Energy Technology Data Exchange (ETDEWEB)
The ternary compound CuInS{sub 2} is attractive for solar cells due to its band gap of 1.54 eV which borders the optimum value necessary for conversion of a solar spectrum. Recently, works on thin film cells based on this material (ZnO/CuInS{sub 2}) has been reported to show efficiency as high as 11.4%. In this paper, the orientation and the morphology of CuInS{sub 2} sprayed films are determined by the means of X-ray diffraction and scanning electron microscopy. Sprayed CuInS{sub 2} films deposited onto a transparent Pyrex substrate with standard fabrication parameters show a chalcopyrite structure with a preferential orientation (1 1 2). A model based on the calculation of the relative dielectric function {epsilon} has been performed in order to obtain the profile of variation of this parameter and to understand the optical behavior of this material via its transmittance and reflectance in visible and near-infrared regions (0.35-2.5 {mu}m). In the same way, ...
2009-07-29
International Nuclear Information System (INIS)
The ternary compound CuInS2 is attractive for solar cells due to its band gap of 1.54 eV which borders the optimum value necessary for conversion of a solar spectrum. Recently, works on thin film cells based on this material (ZnO/CuInS2) has been reported to show efficiency as high as 11.4%. In this paper, the orientation and the morphology of CuInS2 sprayed films are determined by the means of X-ray diffraction and scanning electron microscopy. Sprayed CuInS2 films deposited onto a transparent Pyrex substrate with standard fabrication parameters show a chalcopyrite structure with a preferential orientation (1 1 2). A model based on the calculation of the relative dielectric function ? has been performed in order to obtain the profile of variation of this parameter and to understand the optical behavior of this material via its transmittance and reflectance in visible and near-infrared regions (0.35-2.5 ?m). In the same way, considering the inhomogeneous material ...
2009-07-29
Energy Technology Data Exchange (ETDEWEB)
This paper reports the estimates concerning the atmospheric carbon dioxide absorption and storage by living plants all over the world. It is necessary to decrease atmospheric carbon dioxide concentrations for avoiding global warming. As living plants absorb carbon dioxide by photosynthesis and accumulate carbon in their bodies, they can play an important role to remove atmospheric carbon dioxide. Literatures describing distribution areas, biomass values and net primary productivity (NPP) of forests, marine plants and microorganisms were collected. Examining those data, the biomass and NPP of forests, marine plants and microorganisms can be summarized as follows: (1) Forest biomass and their NPP of the world. The world's forest area is recently estimated as 4 billion hectares, and their biomass is about 400 billion tons of carbon which is equal to 2/3 of the total atmospheric carbon. The NPP of the world's forest is estimated as 25-35 billion tons ...
1992-01-01
Gas evolution in aluminum electrolytic capacitors
Gas evolution in aluminum electrolytic capacitors constitutes one of their main drawbacks in comparison to other types of capacitors lacking a liquid electrolyte. In this respect, one of the most common causes of failure shown by liquid electrolyte capacitors is electrolyte leakage through the seal or even explosions produced by internal pressure buildup. In order to prevent these hazards, some substances, known as depolarizers, are usually added to the capacitor electrolyte with the purpose of absorbing the hydrogen evolved at the cathode (1, 2). Although the gas evolution problem in electrolytic capacitors has been known for a long time, there is a lack of literature on both direct measurements of the gas evolved and assessments of the amount of depolarizer active for the hydrogen absorption process. Aluminum electrolytic capacitors of 100..mu..F and 40V nominal voltage, miniature type (diam 8 mm, height 18.5 mm), were manufactured under standard specifications. ...
1984-03-01
Energy Technology Data Exchange (ETDEWEB)
Atmospheric impact of peatlands is a sum of their gas fluxes. In contrast to carbon dioxide, peatlands are net sources for methane (CH{sub 4}). Methane is an end product in the anaerobic decomposition processes and it has greater capacity to absorb infrared radiation than carbon dioxide. Most of the data on the CH{sub 4} release from northern peatlands is from North America. The total amount of methane released from wetlands is calculated to be 110 Tg yr{sup -1} of which 34 percent (38 Tg yr{sup -1}) is estimated to be emitted from the northern peatlands. Peat with high content of nitrogen is a potential source for gaseous nitrogen oxides, i.e. nitrous oxide (N{sub 2}O) and nitric oxide (NO). However, the importance of peatlands in producing these trace gases is poorly known. Nitrous oxide and nitric oxide are important components in the atmospheric chemistry and N{sub 2}O also is an effective greenhouse gas. Land-use activities and ...
1996-12-31
Activation cross sections of deuteron-induced nuclear reactions on hafnium
International Nuclear Information System (INIS)
Experimental excitation functions for deuteron-induced reactions up to 20 MeV on high purity natural hafnium were measured with the activation method using a stacked foil irradiation technique. Metallic hafnium foils with thickness of 10 #mu#m were stacked together with 50 #mu#m thick aluminium and 12 #mu#m thick titanium foils. The aluminium foils served as energy absorber while the titanium foils were used to monitor the energy and intensity of the bombarding deuteron beam. From a detailed remeasurement of the complete excitation function of the "n"a"tTi(d,x)"4"8V monitor reaction it was possible to adopt the proper incident energy and beam intensity by comparing the results with the recommended values. High resolution off-line gamma-ray spectrometry was applied to assess the activity of each foil. From the measured activity independent and/or cumulative elemental or isotopic cross section data for production of Ta, Hf and Lu radioisotopes by (d,x) reactions were ...
2010-11-15
Energy Technology Data Exchange (ETDEWEB)
Numerical simulations are used to predict the migration of radionuclides from the disposal units at Material Disposal Area G through the vadose zone and into the main aquifer in support of a radiological performance assessment and composite analysis for the site. The calculations are performed with the finite element code, FEHM. The transport of nuclides through the vadose zone is computed using a three-dimensional model that describes the complex mesa top geology of the site. The model incorporates the positions and inventories of thirty-four disposal pits and four shaft fields located at Area G as well as those of proposed future pits and shafts. Only three nuclides, C-14, Tc-99, and I-129, proved to be of concern for the groundwater pathway over a 10,000-year period. The spatial and temporal flux of these three nuclides from the vadose zone is applied as a source term for the three-dimensional saturated zone model of the main aquifer that underlies the site. The ...
1999-07-01
Ozone impacts on the productivity of selected crops. [Corn, wheat, soybean and peanut crops
Energy Technology Data Exchange (ETDEWEB)
The regional impacts of ozone on corn, wheat, soybean, and peanut crops are estimated by using dose-response functions to relate ambient maximum 7 h/d seasonal ozone concentrations to crop productivity data. Linear dose-response functions were developed from open-top field chamber studies. It was assumed that the limited number of cultivars and growing conditions available for the analysis were representative of major agricultural regions. Hourly ozone data were selected to represent rural concentrations and used to calculate maximum 7-h/d average values. Seasonal ozone averages for counties were extrapolated from approximately 300 monitoring sites. Results must be interpreted with knowledge of these assumptions and sources of uncertainty. Impacts are calculated for county units for the conterminous United States with maps showing patterns and tables summarizing the potential magnitude of ozone effects ...
1982-01-01
International Nuclear Information System (INIS)
The activity concentrations of potassium, uranium and thorium in minerals and soil samples from a mining site in Ibadan, Southwestern Nigeria were measured using gamma ray spectroscopy method. Effective dose per annum has been calculated from the activity concentrations of dominant gamma-emitting natural radionuclides, potassium, uranium and thorium. Samples collected include minerals (beryl, quartz and feldspar), soil samples from the mining pits, heaps and undisturbed land around the mining site. The activity concentrations of "4"0K, "2"3"8U and "2"3"2Th, respectively in Bq kg-1 in the mineral samples were as follows: 1985 #+-# 16, 4.8 #+-# 0.9 and 11.8 #+-# 5.8 for beryl sample, 115.1 #+-# 27.9, 5.0 #+-# 1.3 and 6.3 #+-# 5.0 for feldspar samples and 1421 #+-# 122, <4.8 and 20.1 #+-# 3.5 for quartz samples. For the soil samples, the mean activity concentrations of "4"0K, "2"3"8U and "2"3"2Th, respectively, were 314.2 #+-# 5.7, 27.7 #+-# ...
Energy Technology Data Exchange (ETDEWEB)
We have developed a kinetic Monte Carlo (kMC) simulator that links atomic migration and binding energies determined primarily from first principles calculations to macroscopic phenomena and laboratory time scales. Input for the kMC simulation is obtained from a combination of ab initio planewave pseudopotential calculations, molecular dynamics simulations, and experimental data. The simulator is validated against an extensive series of experimental studies of the diffusion of B spikes in self-implanted Si. The implant energy, dose, and dose rate, as well as the detailed thermal history of the sample, are included. Good agreement is obtained with the experimental data for temperatures between 750 and 950 C and times from 15 to 255 s. At 1050o C we predict too little diffusion after 105 s compared to experiment: apparently, some mechanism which is not adequately represented by our model becomes important ...
1998-12-16
Energy Technology Data Exchange (ETDEWEB)
The receptor occupancy-biological effect relationship for muscarinic receptors in guinea pig ileal smooth muscle has been studied by comparison of radioligand binding and contractile response. Muscarinic receptors in homogenates of ileal smooth muscle were labeled with (/sub 3/H)-1-Quinuclidinyl benzilate. Treatment with propylbenzilylcholine mustard (PrBCM), to inactivate irreversibly muscarinic receptors, caused a large dose dependent rightward shift of the dose-response curve to three agonistic furtrethonium derivatives with a concomitant decrease in maximal response. Using those data, the fraction of receptors remaining unoccupied (q-values) and true affinity constants (-log K/sub A/-values) were calculated. Exposure to 20 or 60 nM PrBCM for 15 minutes resulted in a 39% and a 61% reduction in specific (/sup 3/H)-1-Quinuclidinyl benzilate binding sites respectively to be compared with a 62% and a 85% decrease expected ...
1987-10-26
C-14 release and transport from a nuclear waste repository in an unsaturated medium
Energy Technology Data Exchange (ETDEWEB)
The release of {sup 14}C as {sup 14}CO{sub 2} from partly failed spent fuel containers has been analyzed by the flow of gases into and out of the containers. This flow of gases is driven by pressure differences, which are in turn caused by heating by the spent fuel. In this analysis, the timing and size of holes in the containers are assumed to be given. A better means of predicting the time distribution and sizes of penetrations in nuclear waste containers is needed. For the purposes of far-field transport calculations, we have adopted release rates that are shown to be bonding for the large range of hole sizes studied. The transport of released {sup 14}CO{sub 2} has been analyzed by transport in equivalent porous medium. The peak {sup 14}CO{sub 2} concentration in pore gas at 350 m above the repository does not depend on the time of hole occurrence, although the time of penetration obviously affects the arrival and duration of exposure to {sup 14}C. Nor does ...
1990-06-01
International Nuclear Information System (INIS)
The use of absorbable polyglactin 910 mesh (Vicryl) is described in a case of Ewing's sarcoma of the pelvis. An operation was performed to hold the small bowel and colon out of the pelvis for a temporary period during which radical radiotherapy was delivered. The mesh allowed the temporary displacement of bowel and obviated bowel radiation morbidity. (author).
Thermal performance of solar air collectors with a passive heat transfer augmentation technique
Energy Technology Data Exchange (ETDEWEB)
One of the main disadvantages of solar air collectors in practical applications is their relatively low efficiency. In this experimental investigation, the shape and arrangement of absorber surfaces of the collectors were reorganized to provide better heat transfer surfaces suitable for the passive heat transfer augmentation techniques. The performance of such solar air collectors with staggered absorber sheets was tested. The experimental results show that it is possible to provide 10 to 25% enhancement in the efficiency compared to the conventional solar air collectors. (authors)
2000-07-01
The trick with the heat pump; Der Trick mit der Waermepumpe
Energy Technology Data Exchange (ETDEWEB)
The brochure reports on the construction and method of operation of heat pumps: - Efficiency and temperature difference - output figure - circuit processes - saving of primary energy - monovalent and bivalent plants - absorber, earth collectors - heat recovery. (HW) [Deutsch] Die Broschuere berichtet ueber den Aufbau und die Wirkungsweise von Waermepumpen: - Wirkungsgrad und Temperaturdifferenz - Leistungszahl - Kreisprozesse - Einsparung von Primaerenergie - monovalente und bivalente Anlagen - Absorber, Erdkollektoren - Waermerueckgewinnung. (HW)
1997-12-31
Investigation of carbon dioxide absorption by absorbents impregnated with alkanol amines
Energy Technology Data Exchange (ETDEWEB)
In studying the absorption of carbon dioxide by absorbents impregnated with alkanol amines, researchers used a laboratory-scale packed column to determine the overall gas-phase mass-transfer coefficients and enhancement factors. A model derived for the mechanism of the chemical reaction taking place in the interfacial layer accounts for the effect of the reaction upon the absorption rate better than other models.
1981-01-01
Heat exchange in a multi-cavity volumetric solar receiver
Energy Technology Data Exchange (ETDEWEB)
The concept of a multi-cavity volumetric solar receiver is very attractive for the profitability of certain of its characteristics such as high efficiency and economy. The absorber is based on a pack of small ceramic cavities which intercept and absorb the inherent high solar flux reflected from an array of mirrors. Atmospheric air acts as a coolant medium when it is drawn through the pack. A model for an overall heat transfer performance of the receiver is given and numerically solved.
1991-01-01
Energy Technology Data Exchange (ETDEWEB)
LEDF(Large Equipment Dismantling Facility) is the solid waste processing technology development facility that carries out high-volume reduction and low dosage processing. The high-volume reduction processing of the high dose {alpha}-waste configured with combustible waste, pvc and rubber, spent ion exchange resin, and noncombustible waste have been planned the incinerating and melting facility using the in-can type high frequency induction heating in LEDF. This test is intended to clarify the design data. It was confirmed that the incinerating and melting performance, molten solid properties and exhaust gas processing performance with pilot testing equipment and bench scale equipment. The result of this test are as follows. 1. Processing speed is 6.7 kg/h for the combustible waste, 13.0 kg/h for the ion exchange resin, and 30.0 kg/h for the noncombustible waste. For above optimum processing conditions are as follows. Operating temperature is 1000degC for the ...
1999-12-01
Development of barcode system for internal dose monitoring
International Nuclear Information System (INIS)
In Tarapur Atomic Power Station unit-3 and 4, which is 540 MWe pressurized heavy water reactor, tritium is produced in primary heat transport system and moderator system. Tritium is a major contributor to the internal dose. Internal dose contributes about 30% of the collective dose. Internal dose monitoring and its control are important to control the collective dose. Estimation of internal dose is done by analysis of bioassay samples of radiation workers. In a month, about 7000 bioassay samples are analysed for the internal dose assessment during normal operation, and about 12000 during the biennial shut down of the reactor. To enhance the sample preparation and counting performance, minimize the entry errors and reduce the processing time, barcode based label generation system was developed for the internal dose ...
2008-11-19
Evaluation of transient dose in conveyor type low dose irradiator
International Nuclear Information System (INIS)
In conveyor type irradiators, the movement of conveyor and the product boxes is not there until the source is fully in the irradiation position. In case the conveyor system fails the source must automatically be returned to its shielded storage vault. The dose received by the product during the movement of the source from or to the shield becomes significant if the total dose to be received by the product is small. A study has been carried out for evaluating the transient dose received by onions in the POTON irradiator. The results of the study are discussed in this paper. (author)
2003-03-05
Development of internal dose estimation software on radiation protection
International Nuclear Information System (INIS)
Objective: To develop a computerized method of internal dose estimation on radiation protection. Methods: Based on MIRD mathematic model of the organs and by means of the programming language of MS Visual Basic 6.0, a computer program of dose estimation in internal radiation was developed for radiation protection. Results: The computerized method of dose estimation for internal radiation was completed. Conclusions: This computerized method is very convenient for internal radiation dose estimation of several aspects. It can also be used in radiation accident. (authors)
2008-10-01
Collection of athermal phonons into doped Ge thermistors using quasiparticle trapping
Energy Technology Data Exchange (ETDEWEB)
We have developed a low-temperature particle detector that uses a novel quasiparticle trapping mechanism to funnel athermal phonon energy from an 80 mg Ge absorber into a 1.6 mg doped Ge thermistor via a superconducting Al film. We report on pulse height spectra obtained at 320 mK by scanning a {sup 241}Am alpha source along the device, and show that up to 20% of the energy deposited in the Ge absorber by a 5.5 MeV alpha particle interaction can be collected into a thermistor via quasiparticle trapping. We show that this device is sensitive to the position of an alpha particle interaction in the Ge absorber for interaction distances of up to 5 mm from a quasiparticle trap.
1995-05-15
Energy Technology Data Exchange (ETDEWEB)
Iodized oil has been used as a contrast agent in lymphangiography. One of the commercially available compounds is Lipidol Ultra-fluid(LUF) which contains 38% iodine by weight. Nakakuma et al(1979) reported that LUF was selectively retained in the hypervascular hepatocellular carcinoma when injected directly into the ligated hepatic artery. Since that time, it has been widely utilized in the detection as well as the therapeutic attempts of hepatocellular carcinoma, where it has been mixed with chemotherapeutic agents or labeled with radioactive I-131. Like all significant advances, the mechanism of lipid retention within the hepatocellular carcinoma is not clearly understood, and also there is a lack of information about the biodistribution and kinetics of I-131 Lipiodol. The apparent safety of this technique require confirmation. The present study was aimed to assess the biodistribution and kinetics of intraarterially injected I-131 Lipiodol and the histologic changes in canine livers. ...
1989-08-15
X-ray dose enhancement effects
International Nuclear Information System (INIS)
A brief description of the physical process of dose enhancement effects produced by X-ray radiation on materials is given, with emphasis on the influence on electronic devices. The damages caused by X-ray radiation dose enhancement is more serious than that of #gamma#-ray with higher energy.
UK PubMed Central (United Kingdom)
Voxel-based prescriptions of deliberately non-uniform dose distributions based on molecular imaging, so-called dose painting or theragnostic radiation therapy, require specification of a transformation...Full Text Available
2009-03-21
On the accuracy and effectiveness of dose reconstruction for tomotherapy
International Nuclear Information System (INIS)
Dose reconstruction is a process that re-creates the treatment-time dose deposited in a patient provided there is knowledge of the delivered energy fluence and the patient's anatomy at the time of treatment. A method for reconstructing dose is presented. The process starts with delivery verification, in which the incident energy fluence from a treatment is computed using the exit detector signal and a transfer matrix to convert the detector signal to energy fluence. With the verified energy fluence and a CT image of the patient in the treatment position, the treatment-time dose distribution is computed using any model-based algorithm such as convolution/superposition or Monte Carlo. The accuracy of dose reconstruction and the ability of the process to reveal delivery errors are presented. Regarding accuracy, a reconstructed dose distribution was compared with a ...
2001-04-01
Induction of bladder cancer in rats by fractionated intravesicular doses of N-methyl-N-nitrosourea.
UK PubMed Central (United Kingdom)
Experiments were conducted to determine the dose response of rat bladder urothelium to a range of different single and fractionated intravesicular doses of the carcinogen, N-methyl-N-nitrosourea (MNU)....Full Text Available
1982-03-01
Effects of small doses of ionizing radiation on human health
Energy Technology Data Exchange (ETDEWEB)
The risks to human health from small doses of ionizing radiation raise questions which remain largely unanswered. This paper begins by explaining the historical background to this subject; it goes on to discuss recent developments and concludes with a personal view of the dose-reponse relationship. (author).
1997-12-01
Effects of small doses of ionizing radiation on human health
International Nuclear Information System (INIS)
The risks to human health from small doses of ionizing radiation raise questions which remain largely unanswered. This paper begins by explaining the historical background to this subject; it goes on to discuss recent developments and concludes with a personal view of the dose-reponse relationship. (author).
1997-01-01
UK PubMed Central (United Kingdom)
Purpose:To investigate the clinical usage of dose verification of Helical Tomotherapy plans by using 2D-array ion chambers, and to develop an efficient way to validate the dose delivered...Full Text Available
Fission product speciation in Phebus tests FPT0 and FPT1 and the possible influence of boron
Energy Technology Data Exchange (ETDEWEB)
The thermochemical calculations performed with a large number of elements to describe the chemical system in a Phebus FP test allow the following conclusions: The metallic absorber materials play a significant role in fission product speciation. At around 1000 C and above, silver iodide is the dominant iodine carrier in a full steam atmosphere in both FPT0 and FPT1. At lower temperatures, cadmium iodide takes over. In a reduced environment, indium iodide becomes important. Caesium iodide does certainly appear; at certain test conditions it becomes the major iodine transporting vehicle. But its role is not greater than that of the other iodides. It has more chances in FPT1 than in FPT0. Chlorine, which was present in FPT0 as a contaminant in relatively large amounts, does not prevent the iodine from forming Csl. Both share the caesium like partners. The evolution of caesium chloride and iodide proceeds in parallel. When CsCl is abundant, Csl is ...
1996-01-01
X-radiation effects on muscle cell membrane electrical parameters
International Nuclear Information System (INIS)
Early effects of 100 Kilorads of X-rays on muscle cell membrane properties have been measured in sartorius muscles from Leptodactylus ocellatus. Threshold strength for rectangular current pulses increased 10% after irradiation, and action potential propagation velocity decreased 10%. Passive membrane parameters were calculated from potential responses to sub-threshold current pulses, assuming conventional cable theory. Specific membrane conductance increased to 18% after irradiation, membrane capacitance increased 14%, and length constant decreased 10% but membrane time constant was unchanged. Cell diameter decreased 5%, and resting membrane potential decreased 8%. Membrane parameters during an action potential were also evaluated by the phase-plane and current-voltage plot techniques. Irradiation significantly decreased the action potential amplitude, the excitation potential, and the maximum rates of rise and fall of membrane potential. Increases were observed in ...
British Library Electronic Table of Contents (United Kingdom)
Subject of this study is the question of whether cone beam CT (CBCT) images with reduced projection data are suitable for use in adaptive radiation therapy (ART) treatment planning. For this purpose image quality and dose calculation accuracy depending on imaging modality were analysed. In this context, two CBCT-methods will be indicated having reduced projection data sets: Scans acquired with 200^o rotation angle in order to accelerate the CBCT process (half scan), or scans with an asymmetric cone beam and detector offset, used to enlarge the field-of-view (half fan). Methods: For three different CBCT-modes (On-Board-Imaging, Varian Medical Systems), two of them based on reduced projection data, and a conventional multidetector CT system, the main image quality parameters were studied. Tr...
2011-01-01
Homogeneity for highly asymmetric fields has been studied for a Siemens PRIMUS linear accelerator. The flattening filter has a radius smaller than the primary collimator one, creating inhomogeneities that affect large fields in areas far from the collimator axis, and asymmetric fields with large offset. Profiles and absolute dose have been measured in fields with two jaws at maximal position (20 cm) and the other two at maximal overtravel (10 cm.), corresponding to 10 x 10 fields with extreme offset. Profiles have a remarkable gradient decreasing towards the beam edge, making these fields unsuitable for treatments. Results show that the design of the primary collimator and flattening filter assembly has direct consequences in homogeneity. This can have clinical consequences for treatments involving fields that include these inhomogeneous areas. Comparisons with the treatment planning system (Philips Pinnacle) calculations, that computes under ...
2005-01-01
Energy Technology Data Exchange (ETDEWEB)
Objective: To analyze the early response of uveal melanomas in patients treated with ruthenium-106 brachytherapy. Materials And Methods: In the period between April 2002 and July 2003, 20 patients diagnosed with uveal melanoma were submitted to ruthenium-106 brachytherapy. The calculated dose delivered at the apex of the tumor ranged between 55 Gy and 100 Gy. Patients with lesions greater than 5 mm were submitted to transpupillary thermotherapy concomitantly with ophthalmic plaque insertion. Results: As regards the lesions site, 75% of the lesions were located in the choroid, 15% in the iris, and the remainder 10% in the ciliary body. In a median 19-month-follow-up, the progression-free survival for brachytherapy was 69%, and 87% for associated brachytherapy and transpupillary thermotherapy. A significant tumor height reduction was observed after treatment. No patient was submitted to enucleation. Conclusion: Our preliminary results show that ...
2007-03-15
Radiation damage and hardening of molybdenum in 29 MeV alpha particle straggling zone
International Nuclear Information System (INIS)
Technique, allowing to investigate straggling zone (full braking) from high-energy charged particles in detail, is described. Experimental results on investigation of efective structure, created in polycrystalline molybdenum (99.97%) within 29 MeV alpha-particles straggling zone for fluences from 3.8x10"1"9 up to 3.7x10"2"1 #alpha#/m"2 by methods of microhardness (H_#mu#, X-ray structural analysis (#DELTA#a/a) and transparent electron microscopy (TEM), are presented. It is determined, that for doses from 3.8x10"2"0 #alpha#/m"2 and higher, at #approx#6 MeV energy, molybdenum ''softening'' is observed, H_#mu# curve within straggling zone is well described by alloyage calculated profile. #DELTA#a/a measurements within straggling zone are well described by damage profile. TEM-investigations have shown the developed defective structure even within molybdenum ''softening'' range.
RBE and OER measurements on the p(66)+Be neutron beam at Faure, South Africa
International Nuclear Information System (INIS)
Results reported are for single dose exposures and refer to "6"0Co-#gamma#-irradiation. The RBE determined by V79 cell survival and based on the Do ratio was found to be 1.70#+-#0.4 ranging from 1.5 to 1.8. In the case of the regeneration of mouse jejunal crypts the RBE was calculated at ten cell curvival and was found to be 1.68. The maximum acute mouse skin reaction at a skin score of 2.0 was found to be 2.1 while the average skin reaction was 1.7. Growth retardation of Vicia faba bean roots measured at the level of 50% indicated an average RBE of 3.0 and a range of 2.7 to 3.7. The OER obtained for V79 cell survival was found to be 1.7 to 1.8. Comparison is made with the RBE and OER measurements for the neutron facilities at Clatterbridge, Fermilab and Louvain-la-Neuve which produce neutrons by the same nuclear reaction and whose physical specifications closely resemeble those of the Faure neutrons. This comparison indicates that the Faure ...
In response to the consultation from the National Council on Radiation Protection and Measurements (NCRP) to the International Commission on Radiological Protection (ICRP) committee 2, retention and excretion of 239Pu deposited at wound site were calculated by coupling together the proposed NCRP wound model and the current ICRP systemic model of Pu. The physicochemical forms considered were the soluble form categorized into 'Strong Retention', and the colloidal, particulate and fragmentary forms. The results are summarized as follows. If in soluble form, immediate medical intervention is needed to prevent uptake of radionuclides to body tissues, and prompt wound monitoring is essential for an accurate estimation of the initially deposited radioactivity. If in particulate form, a multi-component exponential equation leads to an overestimation of the absorption rate to blood because of significant lymph node drainage. The committed doses in the ...
2007-06-07
International Nuclear Information System (INIS)
The High Flux Isotope Reactor (HFIR) located at Oak Ridge National Laboratory is one of the world's most powerful research reactors. In 1996, one year after the demise of the Advanced Neutron Source Project, the U.S. Department of Energy embarked on an aggressive program to upgrade the neutron scattering facilities at the HFIR. These upgrades, which are now in progress, include the installation of larger beam tubes, a high-performance hydrogen cold source, and additional neutron guides and neutron scattering instruments. An extensive analysis effort was performed over the past 4 yr to support the design of the modified beamlines and new user facilities and to assess the impact of the upgrades on the integrity of the existing reactor system. The results of three of these analyses are summarized here. Specifically, results are presented for analyses related to the design of the new cold neutron source (CNS), the assessment of beam tube changes on the anticipated pressure vessel lifetime, ...
2001-06-17
Mechanical Engineering and Design of the LHC Phase II Collimators
Phase II collimators will complement the existing system to improve the expected high RF impedance and limited efficiency of Phase I jaws. An international collaborative effort has been launched to identify novel advanced materials responding to the very challenging requirements of the new collimators. Complex numerical calculations simulating extreme conditions and experimental tests are in progress. In parallel, an innovative modular design concept of the jaw assembly is being developed to allow fitting in alternative materials, minimizing the thermally induced deformations, withstanding accidents and accepting high radiation doses. Phase II jaw assembly is made up of a molybdenum back-stiffener ensuring high geometrical stability and a modular jaw split in threes sectors. Each sector is equipped with a high-efficiency independent cooling circuit. Beam position monitors (BPM) are embedded in the jaws to fasten setup time and improve beam ...
2010-01-01
Emergency response preparedness for radiological accidents involving wound contamination has become more important, considering the current extending tendency in the nuclear industry related to the nuclear fuel cycle. The US National Council on Radiation Protection and Measurements (NCRP) proposed a biokinetic and dosimetric model for the intake of radionuclides through contaminated wounds in 2007. The present paper describes the implementation of this NCRP wound model for the prediction of systemic behaviour of some important radioactive elements encountered in workplaces related to the nuclear industry. The NCRP wound model was linked to the current ICRP systemic model at each blood compartment and simultaneous differential equations for the content of radioactivity in each compartment and excreta were solved with the Runge-Kutta method. The results of the calculation of wound, whole-body or specific organ retention and daily urinary or faecal excretion rate of ...
2009-05-01
Energy Technology Data Exchange (ETDEWEB)
A new atomistic approach to Si device process simulation is presented. It is based on a Monte Carlo diffusion code coupled to a binary collision program. Besides diffusion, the simulation includes recombination of vacancies and interstitials, clustering and re-emission from the clusters, and trapping of interstitials. We discuss the simulation of a typical room-temperature implant at 40 keV, 5{times}10{sup 13} cm{sup {minus}2} Si into (001)Si, followed by a high temperature (815{degree}C) anneal. The damage evolves into an excess of interstitials in the form of extended defects and with a total number close to the implanted dose. This result explains the success of the {open_quote}{open_quote}+1{close_quote}{close_quote} model, used to simulate transient diffusion of dopants after ion implantation. It is also in agreement with recent transmission electron microscopy observations of the number of interstitials stored in (311) defects. {copyright} {ital 1996 American ...
1996-01-01
International Nuclear Information System (INIS)
A new atomistic approach to Si device process simulation is presented. It is based on a Monte Carlo diffusion code coupled to a binary collision program. Besides diffusion, the simulation includes recombination of vacancies and interstitials, clustering and re-emission from the clusters, and trapping of interstitials. We discuss the simulation of a typical room-temperature implant at 40 keV, 5x10"1"3 cm"-"2 Si into (001)Si, followed by a high temperature (815 degree C) anneal. The damage evolves into an excess of interstitials in the form of extended defects and with a total number close to the implanted dose. This result explains the success of the open-quote open-quote+1 close-quote close-quote model, used to simulate transient diffusion of dopants after ion implantation. It is also in agreement with recent transmission electron microscopy observations of the number of interstitials stored in (311) defects. copyright 1996 American Institute of Physics.
International Nuclear Information System (INIS)
To respond to an increase of social problems concerning orphan sources in Japan, a working group was formed in the Japan Health Physics Society. In this working group, we investigated how to prevent acute radiation hazard or social panic regarding orphan sources in scrap metal and detection system for orphan sources brought into scrap yards before recycle. For detection system in a scrap yard we conducted an experiment on detectability of monitoring instrument using a radiation source mixed in scrap metal on a truck. The result showed that it was not easy to detect even a high-level source if it was shielded by scrap metal. We also estimated detection limits for radioactive materials in scrap metal by calculation that was validated with experimental data. We summarized present status about orphan sources in Japan and proposed a categorization of orphan sources according to dose rates to deal with unknown sources in a scrap yard. Our report ...
2002-10-20
A food basket investigation during the autumn of 1994; Matkorgsundersoekning hoesten 1994
Energy Technology Data Exchange (ETDEWEB)
During the autumn of 1994 an investigation of foodstuffs has been accomplished to assess the average intake of {sup 137}Cs by the Swedish population due to the Chernobyl accident. A standardized food basket has been collected from two grocers in 10 localities, of which the majority came from areas with the highest fallout. The estimated maximum intake of {sup 137}Cs was 815 Bq/year in the inland of the county of Vaesterbotten. The population weighted average intake for the fallout affected counties was 435 Bq/year. The rest of the county received an intake of 235 Bq/year. The population weighted average of the intake for the whole county was estimated to 274 Bq/year. From this intake the calculated body burden would be 1.3 Bq/kg for the average citizen. Whole-body measurements of a sample of the population gave 2.0 Bq/kg. A plausible explanation would be that 40% of the intake of {sup 137}Cs can have its origin from the 10% of the consumption of foodstuffs that are ...
1995-10-01
International Nuclear Information System (INIS)
The objective of this study was to explore the role of three-dimensional (3-D) rotational angiography (RA) of the inferior vena cava (IVC; 3-D CV) before filter retrieval and its impact on treatment planning compared with standard anteroposterior cavography (sCV). Thirty patients underwent sCV and 3-D CV before IVC filter retrieval. Parameters assessed were: projection of filter arms or legs beyond the caval lumen, thrombus burden within the filter and IVC, and orientation of the filter within IVC. Skin and effective radiation doses were calculated. Statistical analysis was performed using paired Student t test and nonparametric McNemar's test. Standard anteroposterior cavography detected 49 filter arms or legs projecting beyond the caval lumen in 25 patients. Three-dimensional CV demonstrated 89 filter arms or legs projecting beyond the caval lumen in 28 patients. Twenty-two patients had additional filter arms or legs projecting beyond the ...
2009-01-01
Radioactivity of people in Finland after the Chernobyl accident in 1986
International Nuclear Information System (INIS)
After the reactor accident at Chernobyl on April 26, 1986 radioactive fallout was carried by air currents to most parts of Europe. The radioactive air currents reached Finland on April 27. Immediately after the arrival of such air in Finland, contamination of people by radioactive nuclides began via inhalation of this air. The ingestion route become important later, when radionuclides were transported via different foodchains to man. To determine the level of radionuclides in the body and to estimate the internal radiation doses caused by the Chernobyl accident, whole-body counting measurements were performed. The results of whole-body counting of six different groups of Finnish people measured during 1986 after the accident at Chernobyl are reported. Three were reference groups measured routinely once or twice annually, two groups were comprised of workers at nuclear power stations and one group consisted of 262 persons not belonging to any other group. The total ...
2004-02-01
International Nuclear Information System (INIS)
To determine the efficacy and safety of Total Dose Infusion (TDI) of low molecular weight iron dextran for the treatment of iron deficiency anemia compared to oral iron replacement during pregnancy through improvement in hemoglobin (Hb) after intervention. Non-randomized control trial. A group of 100 pregnant women with gestational age greater than 12 weeks with confirmed diagnosis of iron deficiency anemia attending the antenatal clinics were enrolled in this study. Total dose iron infusion of low molecular iron dextran was given to these patients after calculating iron deficit, in a monitored in-patient setting. Control comprised of a second group of 50 pregnant females matched for age, parity and baseline hemoglobin, tolerant to oral iron supplementation (ferrous sulphate 200 mg three times a day) attending the antenatal clinics during the same period. Post-treatment hemoglobin levels of study group as well as the oral ...
2008-07-01
The use of nitrogen isotopes in research on sheep nutrition
International Nuclear Information System (INIS)
Using nitrogen-13 initial measurements have been made of rumen ammonia-nitrogen pool size and turnover, and rate of incorporation of ammonia into microbial protein. It is also feasible to measure the rate of incorporation of absorbed ammonia into urea and the appearance of label in saliva.
1985-08-26
The Neutron Radiography Reactor (NRAD)
The Neutron Radiography Reactor (NRAD) operated by Argonne National Laboratory is described in this paper. NRAD was designed to allow radiography of highly absorbing reactor fuel assemblies in the vertical position on the routine basis. 7 figs.
1990-01-01
The Chemical Reactions of Sulfur in the Citrate Process for Flue Gas Desulfurization.
The Bureau of Mines performed chemical research to elaborate details of sulfur chemistry pertaining to the citrate flue gas desulfurization process in which sulfur dioxide (SO2), absorbed (as bisulfite ion) in a buffered sodium citrate solution, is reduce...
1981-01-01
The Atmospheric Trace ... - NASA Langley Science Directorate
Trace gas molecules absorb specific wavelengths of incoming solar ... These data(with information collected from similar experiments carried on balloons, rockets, ... The ATMOS sensor instrumentis a state-of-the-art version of a 19th century ...
Remote disassembly of the absorber open-test assembly at the FFTF/IEM cell
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF) interim examination and maintenance (IEM) cell is used for the remote disassembly of irradiated fuel and material experiments. The absorber open-test assembly (AOTA) is a 12-m (40-ft)-long instrumented absorber (control-rod-material) test assembly. Its primary purpose is to characterize the FFTF control-rod-material reaction rate during reactor operation. Instrumentation allowed temperature and pressure measurements at various locations in several absorber pins during reactor operation. After residing several months in the reactor, the assembly was transferred to the IEM cell by the closed-loop ex-vessel machine (CLEM) for separation of the irradiated portion of the experiment from the instrument stalk. After separation, the 3.6-m (12-ft)-long assembly was processed through the sodium removal system and shipped off-site for examination. This success allowed the timely completion of a major ...
1990-11-11
Energy Technology Data Exchange (ETDEWEB)
The A(..pi../sup +/,/sup 3/He)B reaction near threshold is studied in a model where the pion is absorbed by an /sup 4/He constituent of the target nucleus. The predictions of this model using harmonic oscillator cluster wave functions agree semi-quantitatively with the experimental data on the inverse reaction.
1982-03-10
Incorporate the latest FGD trends into mist-eliminator design. [Flue gas desulfurization
Mist eliminators for flue gas desulphurisation units remove liquid droplets entrained in the flue gas leaving the SO/sub 2/-absorber vessels. The commercial designs currently available are described.
1984-03-01
Gun Barrel Vibration Absorber to Increase Accuracy
Page 1. Page 2. Page 3. Page 4. Page 5. Page 6. Page 7. Page 8. Page 9. Page 10. Page 11. Page 12. Page 13. Page 14. Page 15. Page 16. Page ...
2002-02-01
GaAs Blocked-Impurity-Band Detectors for Far-Infrared Astronomy
Energy Technology Data Exchange (ETDEWEB)
High-purity and doped GaAs films have been grown by Liquid-phase epitaxy (LPE) for development of a blocked impurity band (BIB) detector for far-infrared radiation. The film growth process developed has resulted in the capability to grow GaAs with a net active impurity concentration below 1 x 10{sup 13} cm{sup -3}, ideal for the blocking layer of the BIB detector. The growth of n-type LPE GaAs films with donor concentrations below the metal-insulator transition, as required for the absorbing layer of a BIB detector, has been achieved. The control of the donor concentration, however, was found to be insufficient for detector production. The growth by LPE of a high-purity film onto a commercially grown vapor-phase epitaxial (VPE) n-type GaAs doped absorbing layer resulted in a BIB device that showed a significant reduction in the low-temperature dark current compared to the absorbing layer only. Extended optical response was ...
2004-12-21
First Measurements of the Inclined Boron Layer Thermal-Neutron Detector for Reflectometry
Energy Technology Data Exchange (ETDEWEB)
A prototype detector based on the inclined absorber layer principle is introduced. For the Liquids Reflectometer at the Spallation Neutron Source, it is shown to be a significant improvement over its current detector, which imposes an instantaneous count rate limitation of 50 kcps.
2008-10-01
Design and Validation of a Gun Barrel Vibration Absorber.
Page 1. Page 2. Page 3. Page 4. Page 5. Page 6. Page 7. Page 8. Page 9. Page 10. Page 11. Page 12. Page 13. Page 14. Page 15. Page 16. Page ...
1997-05-01
Current state of methodology on hemoglobin oximetry in tissues.
Photon migration provides sensitive tissue oximetry in which the optical pathlength is known. Phase array gives the precise location of a subnanomolar amount of hidden absorber in highly scattering medium. PMID:8079713
1994-01-01
Carbon dioxide, climate and the sea
Energy Technology Data Exchange (ETDEWEB)
Only half of the carbon dioxide produced by burning fossil fuels stays in the atmosphere. It is thought that the oceans absorb the rest. To understand the world's climate it is necessary to know how the atmosphere, ocean and biosphere interact.
1985-11-21
Carbon dioxide absorption methanol process
Energy Technology Data Exchange (ETDEWEB)
A process is described for removing carbon dioxide from a feed stream of natural gas, having at least methane, ethane and heavier hydrocarbon, comprising: separating the feed stream in a first separator to form a first stream, having substantially all of the propane and heavier hydrocarbons and carbon dioxide and ethane, and a second stream, having methane, carbon dioxide and ethane; mixing the second stream with a polar compound to form a third stream; separating the vapor and liquid of the third stream in the bottom portion of an absorber; absorbing carbon dioxide and ethane from the separated vapor of Step C in a lean portion of the polar compound in the absorber, the absorber carbon dioxide and ethane forming a fourth stream; separating the ethane from the polar compound and carbon dioxide in a separator; separating the first stream in a third separator to separate the propane and heavier ...
1987-06-23
Black holes as detectors of tachyons
International Nuclear Information System (INIS)
Tachyons fired into and absorbed by rotating black holes can violate the second and third laws of black hole physics. It is suggested that apparent break-downs of these laws in astrophysical black holes can indicate the existence of cosmic tachyons. (author).
Adaptive Gun Barrel Vibration Absorber.
Gun barrel vibrations lead to dispersion in the shot patterns. Thus, reducing these vibrations should lead to increased accuracy. Since the muzzle is the anti-node for all vibration modes and its vibrations have the greatest effect on shot dispersion, it ...
2002-01-01
Absorption of tachyons in extended relativity an answer to Basano
International Nuclear Information System (INIS)
It is answered to a previous letter by Basano, and shown that the difficulties met by that author within ''Extended relativity'' do not exist, but are due to the erroneous assumption that a certain condition for tachyons to be absorbed by a macro-object is sufficient (whilst it is only a necessary one).
UK PubMed Central (United Kingdom)
INTRODUCTIONCutiplast (absorbent perforated dressing with adhesive border; Smith & Nephew) is commonly used following orthopaedic operation, but complications of its use...Full Text Available
2006-01-01
Shielding options for the ITER conceptual design
Energy Technology Data Exchange (ETDEWEB)
Several shield options were analyzed for the ITER conceptual design to minimize the nuclear responses in the toroidal field (TF) coils. The total nuclear heating in the physics phase and the insulator dose in the technology phase are the most critical parameters in the design process. The first shield option has type 316 stainless steel and water shielding material. Steel and water also serve as structural material and coolant, respectively. The second option is similar to the first except that borated water is used instead of ordinary water. The other two options include a small layer of lead or boron carbide (B{sub 4}C) at the back of the shield. The last three shield options were considered to reduce the nuclear heating in the toroidal field coils relative to the steel/water shield. An optimization process was performed taking into consideration the thermal-hydraulics and the engineering requirements to define the shield configuration. A careful integration was ...
1989-10-01
Radiation inactivation target size of rat adipocyte glucose transporter
Energy Technology Data Exchange (ETDEWEB)
In situ assembly states of rat adipocyte glucose transport protein in plasma membrane (PM) and in microsomal pool (MM) were assessed by measuring target size (TS) of D glucose-sensitive, cytochalasin B binding activity. High energy radiation inactivated the binding in both PM and MM by reducing the total capacity of the binding (B/sub T/) without affecting the dissociation constant (K/sub D/). The reduction in B/sub T/ as a function of radiation dose was analyzed based on classical target theory, from which TS was calculated. TS in the PM of insulin-treated adipocytes was 58 KDa. TS in the MM of noninsulin-treated and insulin-treated adipocytes were 112 and 109 KDa, respectively. With MM, however, inactivation data showed anomalously low radiation sensitivities at low radiation doses showing a shoulder in the semilog plots, which may be due to an interaction with a radiation sensitive inhibitor. With these results, they ...
1987-05-01
Energy Technology Data Exchange (ETDEWEB)
It is not known whether body weight alone can adjust for the volume of liver in the calculation of the chelating dose in {beta}-thalassaemia major patients, who frequently have iron overload and hepatitis. The hypothesis is that liver volume in children and adolescents suffering from {beta}-thalassaemia major is affected by ferritin level and liver function. Thirty-five {beta}-thalassaemia major patients aged 7-18 years and 35 age- and sex-matched controls had liver volume measured by MRI. Serum alanine aminotransferase (ALT) and ferritin levels were obtained in the thalassaemia major patients. Body weight explained 65 and 86% of the change in liver volume in {beta}-thalassaemia major patients and age-matched control subjects, respectively. Liver volume/kilogram body weight was significantly higher (P<0.001) in thalassaemia major patients than in control subjects. There was a significant correlation between ALT level and liver ...
2005-02-01
Energy Technology Data Exchange (ETDEWEB)
The activity concentrations of potassium, uranium and thorium in minerals and soil samples from a mining site in Ibadan, Southwestern Nigeria were measured using gamma ray spectroscopy method. Effective dose per annum has been calculated from the activity concentrations of dominant gamma-emitting natural radionuclides, potassium, uranium and thorium. Samples collected include minerals (beryl, quartz and feldspar), soil samples from the mining pits, heaps and undisturbed land around the mining site. The activity concentrations of {sup 40}K, {sup 238}U and {sup 232}Th, respectively in Bq kg-1 in the mineral samples were as follows: 1985 +- 16, 4.8 +- 0.9 and 11.8 +- 5.8 for beryl sample, 115.1 +- 27.9, 5.0 +- 1.3 and 6.3 +- 5.0 for feldspar samples and 1421 +- 122, <4.8 and 20.1 +- 3.5 for quartz samples. For the soil samples, the mean activity concentrations of {sup 40}K, {sup 238}U and {sup 232}Th, respectively, were 314.2 +- 5.7, 27.7 ...
2010-01-15
NEUTRON-ABSORBING BRICKS MADE FROM CaB$sup 6$
nsive neutron-absorbing bricks from commercially available CaB/sub 6/ powder. The bricks are 2 x 3 x 5 in., and are strong enough to withstand normal handling. They last indefinitely; the ones described are now 7 years old, used and stored under normal room temperatures and humidities. The procedure is to make a thick, dry mud with the powder and water, followed by compression in a mold at pressures of about 1 ton/in./sup 2/ or more. The bricks are then baked for 2 hours or longer at a temperature of about 750 deg C. (auth)
1960-05-01