Absolute CD4+ T-Lymphocyte Count as a Surrogate Marker of Pediatric HIV Disease Progression
UK PubMed Central (United Kingdom)
BackgroundTraditionally in pediatric HIV, the CD4+ T-lymphocyte percent is used in monitoring disease progression due to the variability in absolute CD4+ T-lymphocyte...Full Text Available
2008-07-01
A high-sensitivity scintillation chamber for radon in gas
Energy Technology Data Exchange (ETDEWEB)
A large scintillation chamber of 6.7 l volume for direct radon concentration measurements in gas is presented. With two 5 in. photomultipliers on opposite sides, working in coincidence, a concentration as low as about 0.5 mBq/l is detectable with 10% standard deviation after 1000 min measuring time. With the achieved background count rate of 0.42 counts/min and the counting efficiency of 0.607 for [sup 222]Rn and its progenies the absolute minimal detectable specific activity is reached with 0.17 mBq/l at about 12 000 min. The method to determine this minimum detectable activity is outlined. ((orig.))
1994-06-15
High-precision Absolute Distance and Vibration Measurement using Frequency Scanned Interferometry
In this paper, we report high-precision absolute distance and vibration measurements performed simultaneously with frequency scanned interferometry using a pair of single mode optical fibers. Absolute distance was determined by counting the interference fringes produced while scanning the laser frequency. A high-finesse Fabry-Perot interferometer(F-P) was used to determine frequency changes during scanning. Two multi-distance-measurement analysis techniques were developed to improve distance precision and to extract the amplitude and frequency of vibrations. Under laboratory conditions, a precision of 40 nm was demonstrated for an absolute distance of approximately 0.45 meters using the first analysis technique. The second analysis technique has capability to measure vibration frequencies ranging from 0.1 Hz to 100 Hz with minimal amplitude on few nanometers order without a priori knowledge.
2004-01-01
Eosinophilia after radiotherapy for non-resected cervical cancer
International Nuclear Information System (INIS)
The behaviors of peripheral eosinophils during radiotherapy were examined in 200 cases of non-resected cervical cancer. Before irradiation, the mean absolute eosinophil count had been 170 +- 168/mm_3, and eosinophilia (more than 500/mm_3) had been observed in 11 cases (5.5%). Postirradiation eosinophilia occurred in 126 cases (63%). The mean period between institution of irradiation and the peak of the eosinophil count was 27.8 days. The mean highest eosinophil count was 691 +- 437/mm_3, and the mean bone marrow dose in this period was 906 rad. Comparisons of the eosinophil count according to the stage showed no significant differences. (Chiba, N.).
1982-01-01
Abces du muscle iliopsoas : complication rare de la sacro-iliite a pyogene chez lenfant
British Library Electronic Table of Contents (United Kingdom)
Pyogenic sacroiliitis is a rare entity in children. Diagnosis is often delayed because of its variable clinical presentation, low suspicion by the examining physician, and rare findings on radiographs. Delayed diagnosis, however, results in complications such as iliopsoas abscess. We report the case of a 12-year-old girl hospitalized with a 21-day history of fever, pain in the left iliac fossa, and flexion contracture of the hip. On examination, she had fever (38.9 ^oC), psoitis, localized tenderness at the left sacroiliac joint, and pain elicited by lateral compression of the pelvis. The abdominal examination was normal. The erythrocyte sedimentation rate was 130mm in the first hour, C-reactive protein was 186mg/l, and the white blood cell count was 18,400/mm^3, with 79% neutrophils. Urin...
2010-01-01
International Nuclear Information System (INIS)
Fifteen quantitative bone scintigraphies were performed in an adolescent girl during the follow-up of a femoral osteogenic sarcoma treated by chemotherapy and massive allograft. Three hours after injection of the radiopharmaceutical (7.4 MBq/kg of 99mTc-MDP) bone activity was measured in the inferior limbs at several regions of interest centered on the hips, femurs (proximal, middle, distal) and proximal tibias. The variations of relative bone activities A/S (ratio of corresponding counting rates between two homologous regions in the affected A and in the healthy S limb) and of absolute bone activities (expressed in counts/pixel-second) are interpreted as a function of times during treatment. The quantitative results are discussed with regard to main phenomena influencing bone activity in this particular clinical case: bone growth, chemotherapy and neo-osteogenesis in allograft.
UK PubMed Central (United Kingdom)
The penetration by moxifloxacin of human neutrophils (polymorphonuclear leukocytes [PMN]) and tissue-cultured epithelial cells (McCoy cells) was evaluated by a fluorometric assay. At...Full Text Available
1999-01-01
Role of Bv8 in neutrophil-dependent angiogenesis in a transgenic model of cancer progression
UK PubMed Central (United Kingdom)
The secreted Bv8 protein has been recently characterized as a regulator of myeloid cell mobilization and a neutrophil-derived mediator of tumor angiogenesis in several xenografts, but its role in tumor...Full Text Available
2008-02-19
UK PubMed Central (United Kingdom)
The phagocytic and killing abilities of heifer mammary gland macrophages (M phi) and neutrophils were evaluated after exposure to recombinant bovine interferon-gamma (rBoIFN-gamma) stimulation in vitro....Full Text Available
1993-07-01
UK PubMed Central (United Kingdom)
A classical velocity centrifugation technique was used to study the in vitro uptake of the new ketolide ABT-773 by human polymorphonuclear neutrophils (PMNs) and a myelomonoblastic cell line, PLB-985,...Full Text Available
2004-04-01
UK PubMed Central (United Kingdom)
Purpose of reviewSevere congenital neutropenia (SCN) is a primary immunodeficiency in which lack of neutrophils causes inadequate innate immune host response to bacterial...Full Text Available
2007-12-01
Effect of pH and osmolality on in vitro phagocytosis and killing by neutrophils in urine.
UK PubMed Central (United Kingdom)
Phagocytosis and intracellular killing of two strains of Escherichia coli and a Staphylococcus saprophyticus by polymorphonuclear neutrophils (PMN) in pooled sterile urine at three osmolalities (800,...Full Text Available
1993-01-01
Reproductive toxicologic evaluations of Bulbine natalensis Baker stem extract in albino rats
British Library Electronic Table of Contents (United Kingdom)
The effects of oral administration of aqueous extract of Bulbine natalensis Baker stem at daily doses of 25, 50, and 100mg/kg body weight on the reproductive function of Wistar rats were evaluated. The indices of mating and fertility success as well as quantal frequency increased after 7 days of treatment in all the dose groups except the 100mg/kg body weight group. The number of litters was not statistically different (P>0.05) from the control. Whereas the absolute weights of the epididymis, seminal vesicle, and prostate were not affected, that of the testes was significantly increased. The epididymal sperm count, motility, morphology, and viscosity were not different from the control after 7 days of treatment. The male rat serum testosterone, progesterone, luteinizing hormone, and follic...
2009-01-01
Development of a small scintillation detector with an optical fiber for fast neutrons
International Nuclear Information System (INIS)
To investigate the characteristics of a reactor and a neutron generator, a small scintillation detector with an optical fiber with ThO_2 has been developed to measure fast neutrons. However, experimental facilities where "2"3"2Th can be used are limited by regulations, and S/N ratio is low because the background counts of this detector are increase by alpha decay of "2"3"2Th. The purpose of this study is to develop a new optical fiber detector for measuring fast neutrons that does not use nuclear material such as "2"3"2Th. From the measured and calculated results, the new optical fiber detector which uses ZnS(Ag) as a converter material together with a scintillator have the highest detection efficiency among several developed detectors. It is applied for the measurement of reaction rates generated from fast neutrons; furthermore, the absolute detection efficiency of this detector was obtained experimentally.
2011-02-01
Characterization of Absolute-Resonant Eddy Current Probes,
... Accession Number : ADD335809. Title : Characterization of Absolute-Resonant Eddy Current Probes,. Corporate Author : ...
Energy Technology Data Exchange (ETDEWEB)
The authors describe the production of two mouse hybridomas secreting monoclonal antibodies to antigenic determinants of the surface membranes of human neutrophils, activated T lymphocytes, and acute leukemic blast cells. The degree of lymphocyte stimulation was estimated from incorporation of /sup 3/H-thymidine with parallel microculture. Monoclonal antibodies of supernatants of hybridoma cultures shown here reacted in both immunofluorescence test and cytotoxicity test with surface membrane antigens on the majority of neutrophils and PHA-activated peripheral blood lymphocytes from healthy subjects, but did not give positive reactions with unactivated lymphocytes, adherent monocytes, erythrocytes, and alloantigen-stimulated lymphocytes.
1987-11-01
Neonatal Sepsis and Neutrophil Insufficiencies
UK PubMed Central (United Kingdom)
Sepsis has continuously been a leading cause of neonatal morbidity and mortality despite current advances in chemotherapy and patient intensive care facilities. Neonates are at high risk for...Full Text Available
2010-06-01
UK PubMed Central (United Kingdom)
Bovine microvascular endothelial cells (MEC) were able to degrade the H2O2 generated by phorbol myristate acetate-activated bovine neutrophils or by glucose oxidase with a maximal capacity of 4.0 +/-...Full Text Available
1986-08-01
Diabetes-Induced Oxidative Stress Is Mediated by Ca2+-Independent Phospholipase A2 in Neutrophils
UK PubMed Central (United Kingdom)
Neutrophils from people with poorly controlled diabetes present a primed phenotype and secrete excessive superoxide. Phospholipase A2 (PLA2)-derived arachidonic acid (AA)...Full Text Available
2010-02-01
British Library Electronic Table of Contents (United Kingdom)
Cholestatic liver injury induced by alpha-naphthylisothiocyanate (ANIT) is provoked by injury to intrahepatic bile ducts and the progression of hepatic necrosis requires the procoagulant protein tissue factor (TF) and extrahepatic cells including neutrophils. Recent studies have shown that myeloid cell TF contributes to neutrophil activation. We tested the hypothesis that myeloid cell TF contributes to neutrophil activation in ANIT-treated mice. TF activity in liver homogenates increased significantly in TF^f^l^o^x^/^f^l^o^x mice treated with ANIT, but not in TF^f^l^o^x^/^f^l^o^x/LysMCre mice (TFD^M^y^e^l^o^i^d mice), which have reduced TF expression in monocytes/macrophages and neutrophils. Myeloid cell-specific TF deficiency did not alter expression of the chemokines KC or MIP-2 but redu...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
The synovial and bone uptake of tracer in the knees of patients with rheumatoid arthritis (RA) was quantified using {sup 99}Tc{sup m}-hexamethyl propylene amine oxime-labelled leucocytes and {sup 99}Tc{sup m}-methylene diphosphonate (MDP), respectively. Significant neutrophil migration and MDP uptake occurred in the knees of patients with RA irrespective of the disease duration. In all but one patient neutrophil migration was reduced after intra-articular steroid injection. The change in MDP uptake after steroid injection was variable. There was a significant correlation between the percentage reduction in neutrophil migration and pain score, while the latter correlated poorly with the change in MDP uptake. The quantification of the neutrophil component of the inflammatory process is a sensitive index for monitoring RA activity and response to pharmacological interventions, while quantitative bone ...
1992-07-01
International Nuclear Information System (INIS)
The synovial and bone uptake of tracer in the knees of patients with rheumatoid arthritis (RA) was quantified using "9"9Tc"m-hexamethyl propylene amine oxime-labelled leucocytes and "9"9Tc"m-methylene diphosphonate (MDP), respectively. Significant neutrophil migration and MDP uptake occurred in the knees of patients with RA irrespective of the disease duration. In all but one patient neutrophil migration was reduced after intra-articular steroid injection. The change in MDP uptake after steroid injection was variable. There was a significant correlation between the percentage reduction in neutrophil migration and pain score, while the latter correlated poorly with the change in MDP uptake. The quantification of the neutrophil component of the inflammatory process is a sensitive index for monitoring RA activity and response to pharmacological interventions, while quantitative bone scintigraphy should not ...
Effects of human serum on bacterial competition with neutrophils for molecular oxygen.
A dialyzable factor(s) in human serum is known to stimulate gonococcal oxygen consumption. Its effect on other human pathogens was investigated. A 10% serum solution increased peak O2 consumption for Escherichia coli and Staphylococcus aureus to 157% (P less than 0.05) and 199% (P less than 0.02), respectively, of their O2 consumption when suspended in Hanks balanced salt solution, compared with a 356% increase for Neisseria gonorrhoeae with serum. Dialyzed serum lacked stimulatory capacity. Bacteria, serum, and neutrophils are often incubated to evaluate neutrophil bactericidal activity. Samples of 10(8) N. gonorrhoeae, S. aureus, and E. coli turned resazurin colorless (anaerobic conditions, Eh less than -42 mV) after 7.4, 13.3, and 15.1 min, respectively. Because neutrophil formation of reactive oxygen intermediates requires ambient O2, the effect of live bacteria and serum on this process was explored. After 5 min of ...
1986-06-01
Feasibility of /sup 252/Cf source driven neutron noise measurements in water moderated reactors
Energy Technology Data Exchange (ETDEWEB)
Previous experiments in fast critical assemblies demonstrated a method of determining reactivity from power spectral density measurements with /sup 252/Cf. This method determines reactivity from properties of the reactor only at the subcritical state of interest, thus it does not require a calibration near delayed criticality. The interpretation of the measured data to obtain reactivity does not require knowledge of the relative or absolute values of the source intensity, knowledge of the detection efficiencies, or knowledge of the detection instrumentation frequency responses. An experiment was performed at the Pool Critical Assembly to evaluate the possibility of /sup 252/Cf source driven neutron noise spectral density measurements in light water moderated reactors. This experiment showed that using commercially available detectors, such measurements can be performed in a reasonable time, that is, the measurement of the quantity of interest (the ratio of spectral ...
1980-01-01
Absolute dimensions of unevolved O type close binaries
Energy Technology Data Exchange (ETDEWEB)
A method is presented to derive the absolute dimensions of early-type detached binaries by combining the observed parameters with results of evolutionary computations. The method is used to obtain the absolute dimensions of nine close binaries. We find that most systems have an initial masss ratio near 1.
1984-03-15
International Nuclear Information System (INIS)
... interval analyzers counting techniques discriminators electronic circuits
UK PubMed Central (United Kingdom)
Electrophysiological events are of central importance during the phagocyte respiratory burst, because NADPH oxidase is electrogenic and voltage sensitive. We investigated the recent suggestion that...Full Text Available
2006-06-01
UK PubMed Central (United Kingdom)
The concentrations of doxycycline and 4-de-dimethylaminotetracycline required to inhibit 50% of collagenase activity were found to be 15 to 30 microM for human neutrophil and gingival crevicular fluid...Full Text Available
1992-01-01
Simultaneous activation of NADPH oxidase-related proton and electron currents in human neutrophils
UK PubMed Central (United Kingdom)
Generation of reactive oxygen species by the NADPH oxidase complex is an important bactericidal weapon of phagocytes. Phorbol myristate acetate (PMA) is a potent agonist for this “respiratory...Full Text Available
2000-06-06
UK PubMed Central (United Kingdom)
BackgroundA deficiency of specific glycosylphosphatidyl inositol-anchored proteins in paroxysmal nocturnal hemoglobinuria may be responsible for most of the clinical features of...Full Text Available
2011-07-01
UK PubMed Central (United Kingdom)
The hyaluronic acid capsule of Streptococcus uberis has been implicated in conferring resistance to phagocytosis by bovine neutrophils. Construction of a bank of random insertion mutants...Full Text Available
2001-01-01
Data reveal that sodium pentobarbital anesthesia does not depress glucose uptake of neutrophils stimulated by the addition of live E. coli. E. coli viability was reduced equally in blood obtained before and after sodium pentobarbital anesthesia. Pre- and ...
1978-01-01
UK PubMed Central (United Kingdom)
Porphyromonas gingivalis has been implicated as a causative pathogen in periodontitis. Immunotherapeutic approaches have recently been suggested to aid in the clearance of P....Full Text Available
2001-05-01
Effect of clindamycin on neutrophil killing of gram-negative periodontal bacteria.
UK PubMed Central (United Kingdom)
Periodontal diseases are infections of the tissues supporting the dentition. Recognition that relatively specific microfloras are associated with distinct clinical forms of periodontal disease has prompted...Full Text Available
1988-10-01
Group B Streptococcus (GBS) is the leading cause of meningitis in newborn infants. Bacterial cell surface appendages, known as pili, have been recently described in streptococcal pathogens, including GBS. The pilus tip adhesin, PilA, contributes to GBS adherence to blood-brain barrier (BBB) endothelium; however, the host receptor and the contribution of PilA in central nervous system (CNS) disease pathogenesis are unknown. Here we show that PilA binds collagen, which promotes GBS interaction with the ?(2)?(1) integrin resulting in activation of host chemokine expression and neutrophil recruitment during infection. Mice infected with the PilA-deficient mutant exhibit delayed mortality, a decrease in neutrophil infiltration and bacterial CNS dissemination. We find that PilA-mediated virulence is dependent on neutrophil influx as neutrophil depletion results in a decrease in BBB permeability and GBS-BBB ...
2011-09-06
(Fast neutron cross section measurements)
Energy Technology Data Exchange (ETDEWEB)
In the 14 MeV Neutron Laboratory, we have continued the development of a facility that is now the only one of its kind in operation in the United States. We have refined the klystron bunching system described in last year's report to the point that 1.2 nanosecond pulses have been directly measured. We have tested the pulse shape discrimination capability of our primary NE 213 neutron detector. We have converted the RF sweeper section of the beamline to a frequency of 1 MHz to replace the function of the high voltage pulser described in last year's report which proved to be difficult to maintain and unreliable in its operation. We have also overcome several other significant experimental difficulties, including a major problem with a vacuum leak in the main accelerator column. We have completed additional testing to prove the remainder of the generation and measurement systems, but overcoming some of these experimental difficulties has delayed the start of actual data ...
1991-01-01
Cross-count identity, distinctness, and the theory of internal and external relations
British Library Electronic Table of Contents (United Kingdom)
Baxter (Australas J Philos 79:449?464, 2001) proposes an ingenious solution to the problem of instantiation based on his theory of cross-count identity. His idea is that where a particular instantiates a universal it shares an aspect with that universal. Both the particular and the universal are numerically identical with the shared aspect in different counts. Although Baxter does not say exactly what a count is, it appears that he takes ways of counting as mysterious primitives against which different numerical identities are defined. In contrast, I defend the idea?suggested, though not quite endorsed, by Baxter himself?that counts are independent dimensions of numerical identity. Different ways of counting are explained by the existence of these different sorts of identity (i.e., counts)...
2010-01-01
The NASA Science Internet - An Integrated Approach to Networking ...
An intemted approach to building a networking infrastructure is an absolute necessiry for meeting the multidisciplinary science networking requirements of ...
...The number of documents that contain the keyword absolute zero is: 2 EU Descartes Prizes for excellence in research and science communication EU Descartes Prizes ...for excellence in research and science communication -Chemistry Close to Absolute Zero - Descartes Prize 2000 - Winner- Ian Smith EU Descartes Prizes for excellence ...in research and science communication EU Descartes Prizes for excellence in research and science communication -Chemistry Close to Absolute Zero - Descartes Prize 2000 ...
Absolute fission rates in the FFTF
Energy Technology Data Exchange (ETDEWEB)
The part of the FFTF Reactor Characterization Program reported in this paper is a measurement of absolute fission rates of eight major fuel isotopes at two different positions within the reactor. The instruments employed in these tests were fission ionization chambers for which the absolute efficiency and fissionable deposit mass assay have been rigorously established.
1981-06-01
... diagnosed. A complete blood count (CBC), urinalysis, blood chemistries, and erythrocyte sedimentation rate (ESR) tests can provide ...
Pedometer Accuracy in Elementary School Children while Walking, Skipping, Galloping, and Sliding
British Library Electronic Table of Contents (United Kingdom)
The purpose of this study was to examine the accuracy of the SW-701 (Yamax Corporation, Tokyo, Japan) and NL-800 (New-Lifestyles, Inc., Lee's Summit, Missouri, USA) pedometer in fifth-grade students while walking, skipping, galloping, sliding, and hopping. Counts registered by both pedometer models were significantly lower than actual counts while skipping, galloping, and sliding, and counts from the NL-800 were significantly lower than the SW-701 during these same movements. No significant differences in step counts were detected between actual counts and the SW-701 and between the pedometer models while walking and hopping; however, the NL-800 registered counts significantly higher than actual counts while hopping. Bland-Altman plots suggest the greatest variability occurred while skippi...
2010-01-01
International Nuclear Information System (INIS)
A comparison is made of the response of a count ratemeter and a pulse counter using the mathematical tool of the Z transform. Transform Z is used for the solution of the convolution integral interpreting the analog output of the count ratemeter used for recording characteristic radiation, excited in the moving beam. The comparison of count rates obtained by the count ratemeter during continuous analysis and the pulse counter during discontinuous measurement gave the transfer function of the count ratemeter in the actual range of count rate. Also discussed is the use of the transfer function for localizing concentration changes in the sample. The use of the described method is demonstrated on the determination of the tin content in tungsten using continuous radionuclide X-ray fluorescence analysis. (B.S.).
1983-01-01
UK PubMed Central (United Kingdom)
A cDNA library was constructed from HL60 human promyelocyte poly(A)+ RNA harvested 3 h after induction of macrophage differentiation with 12-O-tetradecanoyl phorbol-13-acetate in the presence of cycloheximide....Full Text Available
1989-05-01
Novel Biomarkers in Acute Heart Failure
British Library Electronic Table of Contents (United Kingdom)
Heart failure goes beyond mechanical dysfunction and involves an interplay of multiple pathophysiologic mechanisms, including inflammation, tissue remodeling, neurohormonal and endocrine signaling, and interactions with the renal and nervous systems. This article highlights some novel biomarkers that may aid in diagnosis, treatment, and prognosis of acute heart failure, specifically focusing on ST2, endoglin, galectin-3, cystatin C, neutrophil gelatinase?associated lipocalin, midregional pro-adrenomedullin, chromogranin A, adiponectin, resistin, and leptin and their emerging clinical roles.
2011-01-01
UK PubMed Central (United Kingdom)
Retinal pigment epithelial (RPE) cells, derived from the neuroectoderm, biosynthesize the novel lipid mediator neuroprotectin D1 (NPD1) from docosahexaenoic acid (DHA) in response to oxidative...Full Text Available
2010-01-01
UK PubMed Central (United Kingdom)
The present study demonstrates that tumour necrosis factor (TNF) and FMLP, but not IL-1 or IL-8, enhanced the adherence of polymorphonuclear neutrophil (PMN) to fibronectin, an extracellular matrix...Full Text Available
1992-11-01
UK PubMed Central (United Kingdom)
Fifty-six tuberculosis patients and twenty-eight control subjects were evaluated in a comprehensive investigation of cellular and humoral immune function in pulmonary TB. The patient group showed significantly...Full Text Available
1980-05-01
Blood leucocyte count in the human fetus.
UK PubMed Central (United Kingdom)
Total and differential leucocyte counts were measured in cord blood samples obtained by cordocentesis (n = 316) or at elective caesarean section (n = 11) from normal fetuses of between 18 and 40 weeks'...Full Text Available
1992-04-01
Energy Technology Data Exchange (ETDEWEB)
This paper describes statistical methods used to evaluate data for toluene (at several typical operating temperatures and humidity levels) and to determine which measure of humidity (relative or absolute) is more important in determining carbon adsorption efficiency. The water content of a solvent-laden stream is critical for its control via carbon adsorption, especially at relative humidities about 50-70%. (Relative humidity is the percent of saturation: absolute humidity is the total water content.)
1989-01-01
Recursive AR Spectral Estimation.
... ENGINEERING. Personal Author(s) : Ogino,Koji ; Cadzow,James A. Report Date : 1980. Pagination or Media Count : 18. ...
EFFECTS OF EXCIMER LASER IRRADIATION ON THE ...
... Personal Author(s) : ROTHSCHILD, M. ; EHRLICH, DJ ; SHAVER, DC. Report Date : 1989. Pagination or Media Count : 3. ...
ECONOMICS OF RELIABILITY IMPROVEMENT FOR SPACE ...
... Pagination or Media Count : 205. Abstract : Present methods for planning reliability improvement of launch vehicles are reviewed. ...
1968-06-01
Combustible Cartridge Case and Method of Making Same.
... Pagination or Media Count : 4. Abstract : The invention relates to combustible cartridge cases and to a method of making same. ...
1961-05-02
CAPACITOR DISCHARGE METAL FORMING
... Report Date : JUL 1961. Pagination or Media Count : 39. Abstract : Open-ende Terms: Electrohydraulic forming, Magnetic forming. ...
1961-07-01
Quantitative cerebral blood flow with Optical Coherence Tomography
UK PubMed Central (United Kingdom)
Absolute measurements of cerebral blood flow (CBF) are an important endpoint in studies of cerebral pathophysiology. Currently no accepted method exists for in vivo longitudinal...Full Text Available
2010-02-01
Probe-Flaw Interactions with Eddy Current Array Probes
... The development of various modeling methods for conventional eddy current probes (absolute, differential, two-port, etc.) has led to a general ...
Enhancement of Keratinocyte Differentiation by Rose Absolute Oil
UK PubMed Central (United Kingdom)
BackgroundThrough differentiation processes, keratinocytes provide a physical barrier to our bodies and control skin features such as moisturization, wrinkles and pigmentation. Keratinocyte...Full Text Available
2010-08-01
The Effect of Cocktail on Radiocarbon Analysis by Direct Absorption of Carbon dioxide
International Nuclear Information System (INIS)
Carbon-14 was analysed by direct absorption of carbon dioxide on the mixture of organic amine compound and scintillation cocktail then counted by low level liquid scintillation counter. This method can be applied for radiocarbon dating. In this study, the effects of carbon dioxide absorption, and counting efficiency were investigated using various commercial available cocktail. It was found that permafluor V and Ready Gel showed the highest carbon dioxide absorption whereas the Permafluor V showed the highest counting efficiency
1998-12-01
International Nuclear Information System (INIS)
The nuclide "2"4"1Am decays by alpha emission to "2"3"7Np. Most of the decays (84.6%) populate the excited level of "2"3"7Np with energy of 59.54 keV. Digital coincidence counting was applied to standardize a solution of "2"4"1Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid scintillation counting using the logical sum of double coincidences in a TDCR array and defined solid angle counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.
2009-09-07
International Nuclear Information System (INIS)
Tachyon paradoxes, including causality paradoxes, have persisted within tachyon theories and left little hope for the existence of observable tachyons. A way is presented to solve the causality paradoxes, along with two other paradoxes, by the introduction of an absolute frame of reference in which a tachyon effect may never precede its cause. Relativity for ordinary matter is unaffected by this, even if the tachyons couple to ordinary particles. Violations of the principle of relativity due to the absolute frame would appear only in the case of free tachyons.
Energy Technology Data Exchange (ETDEWEB)
Here the authors try to dissolve some commonly held misconceptions about the operation of eddy current probes used for inspecting heat exchanger tubes. With the help of computer model results, the authors demonstrate that, for optimized operation, absolute/differential probes should be operated with coil current flowing in phase with another. This month's feature should be of interest to researchers as well as for NDT field personnel.
2000-05-01
Absolute absorption of ozone in the midinfrared
Energy Technology Data Exchange (ETDEWEB)
The absolute absorption of ozone in the midinfrared has been measured relative to 253.7-nm ultraviolet absorption to an accuracy of 1% using a Bruker Fourier transform spectrometer. These new results agree with previous measurements by diode laser measurements after the latter are corrected for more recent infrared calculations and ultraviolet cross sections. They also agree with a determination based on refractive index measurements in the infrared. 16 refs., 4 figs., 3 tabs.
1992-12-20
Quantitative bone scintigraphy in prostatic carcinoma - long-term response to treatment
Energy Technology Data Exchange (ETDEWEB)
Quantitative bone scintigraphy was performed in 24 patients with prostatic carcinoma before orchiectomy and up to one to four years after operation. The gamma camera count rate was recorded over the lower thoracic and all lumbar vertebrae 4 h after injection of [sup 99m]Tc-MDP. Twelve patients has normal bone scintigrams throughout the study. They showed from two years after operation a slight increase in count rate values compared with the preoperative values, probability due to hormonal changes after orchiectomy and to age-related alterations in skeletal metabolism. Twelve patients had abnormal bone scintigrams. They showed as a response to treatment the flare phenomenon with an increase in count rate over the abnormal vertebrae when measured two weeks after operation followed by a decrease after two months. The lowest count rate values were obtained between six months and one year after operation. ...
1993-10-01
Quantitative bone scintigraphy in prostatic carcinoma - long-term response to treatment
International Nuclear Information System (INIS)
Quantitative bone scintigraphy was performed in 24 patients with prostatic carcinoma before orchiectomy and up to one to four years after operation. The gamma camera count rate was recorded over the lower thoracic and all lumbar vertebrae 4 h after injection of "9"9"mTc-MDP. Twelve patients has normal bone scintigrams throughout the study. They showed from two years after operation a slight increase in count rate values compared with the preoperative values, probability due to hormonal changes after orchiectomy and to age-related alterations in skeletal metabolism. Twelve patients had abnormal bone scintigrams. They showed as a response to treatment the flare phenomenon with an increase in count rate over the abnormal vertebrae when measured two weeks after operation followed by a decrease after two months. The lowest count rate values were obtained between six months and one year after operation. ...
Counting is among the most fundamental operations in computing. For example, counting the pth frequency moment has been a very active area of research, in theoretical computer science, databases, and data mining. When p=1, the task (i.e., counting the sum) can be accomplished using a simple counter. Compressed Counting (CC) is proposed for efficiently computing the pth frequency moment of a data stream signal A_t, where 0= 0, which includes the strict Turnstile model as a special case. For natural data streams encountered in practice, this restriction is minor. The underly technique for CC is what we call skewed stable random projections, which captures the intuition that, when p=1 a simple counter suffices, and when p = 1+/\\Delta with small \\Delta, the sample complexity of a counter system should be low (continuously as a function of \\Delta). We show at small \\Delta the sample complexity (number of ...
2008-01-01
Tritium monitor with improved gamma-ray discrimination
Energy Technology Data Exchange (ETDEWEB)
Apparatus and method for selective measurement of tritium oxide in an environment which may include other radioactive components and gamma radiation, the measurement including the selective separation of tritium oxide from a sample gas through a membrane into a counting gas, the generation of electrical pulses individually representative by rise times of tritium oxide and other radioactivity in the counting gas, separation of the pulses by rise times, and counting of those pulses representative of tritium oxide. The invention further includes the separate measurement of any tritium in the sample gas by oxidizing the tritium to tritium oxide and carrying out a second separation and analysis procedure as described above.
1985-01-01
Energy Technology Data Exchange (ETDEWEB)
The use of canisters filled with a charge of activated charcoal for field measurements of radon surface-emanation rates is well known. The performance of a canister, which is in current use by uranium mining companies and statutory authorities throughout Australia, was investigated using various charcoal thicknesses. To avoid the lower counting efficiencies associated with the smaller charges when measured at the exposed end, the canisters were counted from the closed end, which has become current practice for this canister.
1984-05-01
International Nuclear Information System (INIS)
Using the electron energy-loss method in a merged electron-ion beams geometry absolute, cascade-free excitation cross sections have been measured for the resonance "2S#->#"2P transition in Zn"+. Measurements were carried out at electron energies of below threshold (threshold at 6.011 eV) to 40 eV. Results are in very good agreement with close-coupling calculations and, away from threshold, lie below absolute line-emission cross sections which include effects of cascade into the "2P state from higher levels.
1991-02-20
International Nuclear Information System (INIS)
The use of primary electron counting techniques as an alternative to the more usual parallel plate avalanche chamber that has been employed in soft x-ray scattering experiments is being investigated at the National Synchrotron Light Source. The theoretical aspects of primary electron counting and motivation behind building a primary electron counting detector are described, as well as characteristics and future improvements of the device constructed at the NSLS. The detector consists of a low electric field drift region and a low pressure multistep avalanche region which can be operated with two or three stages of electron multiplication. The device has worked well in extensive tests as a simple parallel plate avalanche chamber, providing energy resolutions of 58% and 43% at 277 and 500 eV, respectively. Operated as a primary electron counter, preliminary results show an energy resolution of 38% at 500 eV.
Trip Report - Logistical Support for an Independent Brigade.
... Pagination or Media Count : 4. Abstract : The Support Battalion, 3rd Brigade, 82nd Airborne Division was visited on 7 December 1968. ...
1968-12-12
Standardisation of "2"1"0Pb by Cerenkov counting
International Nuclear Information System (INIS)
A standard of "2"1"0Pb in solution was produced at the National Physical Laboratory by a novel technique combining Cerenkov counting with the established liquid scintillation efficiency tracing technique known as the CIEMAT/NIST method. Coincidence counting was applied in order to validate the measurements and the activity concentrations of the solution determined with each technique are shown to be in agreement. Radiochemical separation of the "2"1"0Pb from its daughters was also necessary and the scheme for the separation is described. After performing this two-stage standardisation, the uncertainty was successfully lowered to 0.66% (k=1). This uncertainty is approximately a factor of four lower than previously achieved at NPL by the classical method of standardisation of radionuclides, i.e. coincidence counting.
2011-05-01
Precise measurements of alpha particle counting efficiencies and mean ranges
International Nuclear Information System (INIS)
Precise measurements of alpha particle counting efficiencies have been made using isotropic, infinitely thin alpha emitting sources placed in direct contact with a thin, end-window, gas flow proportional detector. Except for alpha particle absorption in the window material, this geometry approaches 2#pi#, such that the only other variation in the response of the counter is from the random decay of the source. The data are fitted to the expected linear function of count rate versus window thickness and the resulting fitting parameters are used to calculate the counting efficiencies for a given thickness of window material. Counting efficiencies for 5.31, 6.06, and 8,78 MeV alpha particles have been determined from sources of "2"1"0Po and the progeny of "2"1"2Pb. For the particular counter used, the counting efficiencies in counts per alpha and their respective ...
1978-12-01
LAMBDA - IRAS Faint Source Survey Plates - LAMBDA - NASA
Apr 18, 2008 ... The FSS was produced by point-source filtering the individual detector data ... a 1-sigma noise map; and a coverage map giving the count of ...
Habitat Selection by Mountain Plovers in Shortgrass Steppe
... the area covered by the point-count grid, stopping approximately every 100 m, stepping away from the vehicle, and scanning with binoculars for mountain plovers. Once ... ...
International Nuclear Information System (INIS)
Full text: Certain groups of patients have been excluded from ventilation lung scanning due to their inability to comply with instruction. Tetley Manufacturing have recently developed a Positive Ventilation Delivery System (PVDS) which assists in delivering Technegas to patients who are unable to cooperate fully. The aim of this study is to evaluate the PVDS in the clinical setting. Fifteen frail aged and psychogeriatric patients (n=l 5), mean age 78 years (range 60-93), were ventilated with Technegas using the PVDS. The decision to ventilate the patient with the PVDS was based on an initial assessment of the patients ability to comply with instructions, or failure of the conventional ventilation method, to produce an adequate count rate. Technegas was prepared in the usual manner and then delivered to the patients lungs by squeezing a black anesthetic bag synchronously with the patients breathing, until a count rate of approximately 1000 ...
1998-06-01
Development Statistics for the UH-1 Ada Feasibility Study
... to the actual size base on the terminal semicolon counting ... I Queue and stack control. ... analysis: highly accurate analysis of noisy, stochastic data. ...
1992-01-01
Delta connected resonant snubber circuit
Energy Technology Data Exchange (ETDEWEB)
A delta connected, resonant snubber-based, soft switching, inverter circuit achieves lossless switching during dc-to-ac power conversion and power conditioning with minimum component count and size. Current is supplied to the resonant snubber branches solely by the dc supply voltage through the main inverter switches and the auxiliary switches. Component count and size are reduced by use of a single semiconductor switch in the resonant snubber branches. Component count is also reduced by maximizing the use of stray capacitances of the main switches as parallel resonant capacitors. Resonance charging and discharging of the parallel capacitances allows lossless, zero voltage switching. In one embodiment, circuit component size and count are minimized while achieving lossless, zero voltage switching within a three-phase inverter.
1998-01-01
"Machines of all kinds depend on complex software to keep them operating safely. But how reliable is the software - and how can we be sure it is reliable?" (4 pages)
1989-01-01
CHANEXTDFS - Chandra Extended Deep Field South Survey Point Source ...
Jan 25, 2006 ... Source positions are determined using matched-filter and centroiding .... The upper 1-sigma statistical error in the full-band counts. ...
An Investigation of Filled and Plasticized Polyvinyl Chloride,
... Personal Author(s) : Tarasenko,Yu. G. ; Venediktov,MV ; Dyshchenko,VP ; Kolupaev,BS. Report Date : 25 AUG 1972. Pagination or Media Count : 16 ...
1972-08-25
Adaptive ARMA Spectral Estimation,
... ENGINEERING. Personal Author(s) : Cadzow,James A. ; Ogino,Koji. Report Date : 1981. Pagination or Media Count : 7. Abstract ...
A Survey of Flow Cytometry Data Analysis Methods
UK PubMed Central (United Kingdom)
Flow cytometry (FCM) is widely used in health research and in treatment for a variety of tasks, such as in the diagnosis and monitoring of leukemia and lymphoma patients, providing the counts of helper-T...Full Text Available
2009-01-01
[sup 3]He([ital n],[gamma])[sup 4]He cross section and the photodisintegration of [sup 4]He
Energy Technology Data Exchange (ETDEWEB)
The absolute cross section of the [sup 3]He([ital n],[gamma])[sup 4]He reaction was measured at five energies between [ital E][sub [ital n
1993-11-01
Using and Interpreting Adjusted NNT Measures in Biomedical Research
UK PubMed Central (United Kingdom)
The number needed to treat (NNT) is a popular effect measure to present study results in biomedical research. NNTs were originally proposed to describe the absolute effect of a new treatment compared...Full Text Available
UK PubMed Central (United Kingdom)
The clotting activity of Staphylococcus aureus strain 104 was purified 46,000-fold, but absolute purity was not achieved. Carbohydrate content of the purified material was not more than 5%. Elution...Full Text Available
1981-12-01
NASA JOHNSON SPACE CENTER ORAL HISTORY PROJECT ORAL
Jan 15, 2004 ... thought I would have a difficult time working with. ...... they were absolutely right, because everybody said it rained cats and dogs on the orbit ...... We know that in the military. You can ask any military ...
UK PubMed Central (United Kingdom)
Choice procedures have indicated that the relative reinforcing effectiveness of opioid drugs increases during opioid withdrawal. The demand curve, an absolute measure of reinforcer value, has not been...Full Text Available
2011-01-01
FFTF (Fast Flux Test Facility) Reactor Characterization Program: Absolute Fission-rate Measurements
Energy Technology Data Exchange (ETDEWEB)
Absolute fission rate measurements using modified National Bureau of Standards fission chambers were performed in the Fast Flux Test Facility at two core locations for isotopic deposits of {sup 232}Th, {sup 233}U, {sup 235}U, {sup 238}U, {sup 237}Np, {sup 239}Pu, {sup 240}Pu, and {sup 241}Pu. Monitor chamber results at a third location were analyzed to support other experiments involving passive dosimeter fission rate determinations.
1981-05-01
FFTF (FAST FLUX TEST FACILITY) REACTOR CHARACTERIZATION PROGRAM ABSOLUTE FISSION RATE MEASUREMENTS
Energy Technology Data Exchange (ETDEWEB)
Absolute fission rate measurements using modified National Bureau of Standards fission chambers were performed in the Fast Flux Test Facility at two core locations for isotopic deposits of {sup 232}Th, {sup 233}U, {sup 235}U, {sup 238}U, {sup 237}Np, {sup 239}Pu, {sup 240}Pu, and {sup 241}Pu. Monitor chamber results at a third location were analyzed to support other experiments involving passive dosimeter fission rate determinations.
1981-05-01
Energy Technology Data Exchange (ETDEWEB)
In this book the notion of time in classical physics and relativity theory is discussed. After a criticism of the absolute time some alternative measures of time in mechanics are considered. Thereafter the problem of equal time at different points of the space as well as the time in different inertial systems are considered. In this framework the clock paradox is discussed. Then the Lorentz transformation is considered. Thereafter the reconstruction of the absolute time in relativity theory is described. Finally the notion of time in general relativity theory is considered.
1980-01-01
International Nuclear Information System (INIS)
Absolute, cascade-free excitation cross sections in an ion have been measured for the resonance "2S#->#"2P transition in Zn"+ using electron-energy-loss and merged electron-ion beams methods. Measurements were carried out at electron energies of below threshold to 6 times threshold. Comparisons are made with 2-, 5-, and 15-state close-coupling and distorted-wave theories. There is good agreement between experiment and the 15-state close-coupling cross sections over the energy range of the calculations.
The size of the hole in the ozone layer | Environment | guardian.co.uk
... Space weather is the biggest driver of ozone depletion and much else we are only beginning to understand. Solar Cycle 24 may turn out to be weak in terms of sun spot count but the amount of energy delivered by CME/SPE will probably not be. Remember that the Carrington Event in 1859 happened during a cycle with a lowish sun spot count. Recommend (1) Report abuse ...
Mechanisms of the pulse rise-time variations in X-ray proportional counters
Energy Technology Data Exchange (ETDEWEB)
The paper presents a description of the physical processes governing the variations of the pulse rise-time which occur during the operation of the proportional counter and are due to varying either the count rate or the applied voltage. On the basis of the rise-time concept the differences in the count rate effect observed in various types of proportional counters are discussed.
1981-01-01
Developing DB system of piping reliability
Energy Technology Data Exchange (ETDEWEB)
Developing DB system of piping reliability including the population data and service history of damaged piping for pilot power plant. Total weld counts of shop welds, field welds and welds for measuring instruments for 14 systems of Kori unit 3. Total weld counts of shop welds, field welds and welds for measuring instruments for 12 systems of Wolsung unit 2.
2005-03-15
Automated remote positioning and examination of FFTF reactor power characterization dosimeters
Energy Technology Data Exchange (ETDEWEB)
The Fast Flux Test Facility (FFTF) reactor characterization by the Hanford Engineering Development Laboratory (HEDL) includes extensive neutronic measurements during startup and initial operation. To aid in the handling and counting of the thousands of passive dosimeters used as part of this effort, an automated dosimetry specimen handling, positioning, and counting system was designed and developed by Westinghouse Hanford for the Department of Energy.
1981-05-04
Aqueous liquid scintillation counting with fluor-containing nanosuspensions
Energy Technology Data Exchange (ETDEWEB)
A microemulsion comprised of water, Brij 78, pentanol and styrene into which PPO and bis-MSB had been dissolved was prepared. Polymerization of the styrene resulted in a suspension of fluor-containing polystyrene nanoparticles (<100 nm). After a concentration step, the aqueous nanosuspension was able to detect {sup 14}C with counting efficiencies over 50% of those of a commercially available scintillation cocktail. Monte Carlo calculations demonstrated that the size and concentration of the nanoparticles were appropriate for optimum detection efficiency.
2004-06-01
Tetracycline ulcers of the oesophagus
Energy Technology Data Exchange (ETDEWEB)
Two cases of tetracycline ulcers of the oesophagus are reported and compared with thirteen other cases from the literature. In most cases, the patients had taken their capsules with little or no fluid just before going to bed. Some hours later they developed retrosternal pain that was intensified by swallowing. Endoscopy showed sharply demarcated greyish-white areas of mucosal damage which represented layers of stratified squamous cells, separated by oedema, and a dense neutrophilic infiltration of the lamina propria and the muscularis mucosa. Roentgenology was unsuitable to detect the lesions. They healed without complications within one to six weeks. Prolonged retention of the capsules in the oesophagus is thought to cause the mucosal damage. Patients on oral tetracycline or doxycycline treatment should therefore be instructed to take their capsules with a meal or with copious water and not just before going to bed.
1981-11-01
British Library Electronic Table of Contents (United Kingdom)
Ex vivo expanded peripheral blood progenitor cells (PBPC) have been shown to provide rapid neutrophil engraftment, and in some patients, to eliminate neutropenia after transplantation to support high-dose chemotherapy. However, the effect of expansion culture on stem cell content and potential loss of stem cells caused by induction of differentiation remains a concern. We have transplanted 21 patients with breast cancer with expanded autologous PBPC, with 11 patients receiving expanded PBPC as their sole hematopoietic cell source. In these studies, the CD34+ cells were selected and cultured for 10 days in defined media containing 100 ng/mL each of recombinant human stem cell factor (rhSCF), recombinant human granulocyte colony stimulating factor (rhG-CSF), and recombinant human megakaryocy...
2006-01-01
Glycyrrhizin attenuates the development of carrageenan-induced lung injury in mice
British Library Electronic Table of Contents (United Kingdom)
Glycyrrhizin is a triterpene glycoside, a major active constituent of licorice (Glycyrrhiza glabra) root and numerous pharmacological effects like anti-inflammatory, anti-viral, anti-tumour and hepatoprotective activities has been attributed to it. In this study we evaluated the anti-inflammatory activities of glycyrrhizin in mice model of acute inflammation, carrageenan-induced pleurisy. We report here that glycyrrhizin (given at 10mg/kg i.p. 5min prior to carrageenan) exerts potent anti-inflammatory effects in this model. Injection of carrageenan into the pleural cavity of mice elicited an acute inflammatory response characterized by fluid accumulation in the pleural cavity which contained a large number of neutrophils (PMNs) as well as an infiltration of PMNs in lung tissues and subsequ...
2008-01-01
Quantitative monitoring of the fluorination process by neutron counting
Energy Technology Data Exchange (ETDEWEB)
Plutonium metal is produced by reducing PuF{sub 4} prepared from PuO{sub 2} by fluorination. Both fluorination and reduction are batch processes at the Los Alamos Plutonium Facility. The conversion of plutonium oxide to fluoride greatly increases the neutron yield, a result of the high cross section for alpha-neutron ({alpha},n) reactions on fluorine targets compared to the (more than 100 times) smaller {alpha},n yield on oxygen targets. Because of the increase, total neutron counting can be used to monitor the conversion process. This monitoring ability can lead to an improved metal product, reduced scrap for recycle, waste reduction, minimized reagent usage, and reduce personnel radiation exposures. A new stirred-bed fluorination process has been developed simultaneously with a recent evaluation of an automated neutron-counting instrument for quantitative process monitoring. Neutrons are counted with ...
1993-12-31
Energy Technology Data Exchange (ETDEWEB)
Quantitative bone scintigraphy was performed at 4 and 24 h after injection of {sup 99m}Tc-MDP. The lower thoracic and all the lumbar vertebrae were recorded in 37 patients with prostatic carcinoma before orchiectomy as well as two weeks, two and six months postoperatively. Fourteen patients had normal bone scintigrams. By means of the measured variation in the count rate between normal vertebrae, the criterion for a vertebra to be considered as abnormal was determined using the 4 h-uptake values. For patients with normal scintigrams the count rate at 24 h was below the 4 h level and the mean 24 h/4 h ratio was determined to be 0.85 {+-} 0.09 (1 SD). Normal vertebrae in patients with skeletal metastases had only slightly lower count rate values at 24 h than at 4 h. Abnormal vertebrae showed a higher count rate at 24 h, especially two weeks postoperatively, while a tendency towards lower values than at 4 ...
1991-01-01
International Nuclear Information System (INIS)
Quantitative bone scintigraphy was performed at 4 and 24 h after injection of "9"9"mTc-MDP. The lower thoracic and all the lumbar vertebrae were recorded in 37 patients with prostatic carcinoma before orchiectomy as well as two weeks, two and six months postoperatively. Fourteen patients had normal bone scintigrams. By means of the measured variation in the count rate between normal vertebrae, the criterion for a vertebra to be considered as abnormal was determined using the 4 h-uptake values. For patients with normal scintigrams the count rate at 24 h was below the 4 h level and the mean 24 h/4 h ratio was determined to be 0.85 #+-# 0.09 (1 SD). Normal vertebrae in patients with skeletal metastases had only slightly lower count rate values at 24 h than at 4 h. Abnormal vertebrae showed a higher count rate at 24 h, especially two weeks postoperatively, while a tendency towards lower values than at 4 h ...
International Nuclear Information System (INIS)
Lithium carbonate pellets are frequently used for estimation of tritium production rate in irradiated samples in fusion blanket neutronics experiment and the activity is measured by liquid scintillation counting technique. In this measurement, it is essential to solve the lithium carbonate pellet as much as possible and to mix the pellet solution into scintillation cocktail homogeneously at stable condition. For this purpose, a novel binary-acid method has been developed to solve lithium carbonate and to mix the pellet solution into scintillation cocktail. High solubility is attained by adopting two acids, HNO_3 and CH_3COOH, and a good compatibility of the pellet solution with scintillator is obtained by emulsion cocktail resulting in high counting efficiency. Defining a product of dissolved mass and counting efficiency as a Figure of Merit (FOM), the present method has higher FOM value than the conventional method and is ...
Endothelial dysfunction and increased platelet aggregation may be involved in the pathogenesis of normal tissue radiation toxicity. This study assessed clopidogrel, an inhibitor of ADP-induced platelet aggregation, as a modulator of intestinal radiation injury (radiation enteropathy). Rat small intestine was exposed to 21 Gy X-radiation. Clopidogrel (20 mg/kg/day) or vehicle was administered from 2 days before to 10 days after irradiation. Structural radiation injury, neutrophil infiltration, smooth muscle cell proliferation, collagen content, and TGF-beta1 expression were assessed 2 weeks (early phase) and 26 weeks (delayed phase) after irradiation, using quantitative histology and immunohistochemistry, morphometry, and real-time fluorogenic probe RT-PCR. Irradiated intestine exhibited significant histopathologic injury, reduced mucosal surface area, vascular sclerosis, intestinal wall fibrosis, increased collagen content, and increased TGF-beta1 expression. ...
2002-01-01
Gene rearrangement and radiation carcinogenesis
International Nuclear Information System (INIS)
The development of leukemia and thyroid cancer is characterized by activation of the abl oncogene and ret oncogene, respectively. In order to clarify the relationship between these gene aberrations and radiation, the pro-myelogenous leukemia-derived cell line HL60 and the thyroid cancer-derived cell line 8505C, were irradiated in vitro with 100Gy of X-rays. RNA was then extracted from 10"8 cells of the respective cell lines and examined by the reverse transcription PCR method for rearrangements of abl and ret genes. Five kinds of positive bands were observed in the HL-60 cells irradiated with 100Gy of X-ray. Similarly, six positive bands were also observed in the 8505C cells irradiated with 100Gy. In vitro X-irradiation activation of oncogenes found in radiation induced cancers imply that gene rearrangement by X-rays is involved in the development of malignant tumors. Furthermore, in an experiment to detect radiation effects in A-bomb survivors, RNA was extracted from about 10"7 ...
1993-11-01
Cadmium telluride single crystals were grown heavily doped with chloride by the THM method. The resulting crystals were n-type with free carrier concentrations of the order of 10('12)/cm at room temperature. Hall effect studies revealed room temperature mobilities between 30 and 350 cm('2)/v-sec and resistivites between 2 x 10('3) and 10('4) ohm-cm. Studies were made of the gamma and alpha counting characteristics of these crystals with metal, metal-semiconductor, and metal-insulator electrodes. It was found that the MIS and MSS structures resulted in significant improvement over the MS structures in counting, signal-to-noise and energy resolution.
1985-01-01
Studies of basic parameters of electron-counting detection
International Nuclear Information System (INIS)
Measurements have been made of certain parameters relevant to the operation of electron-counting detectors. An experimental chamber consisting of a uniform-field drift tube and a coaxial proportional counter thas been employed to obtain data, at very low drift fields (E/p<0.02 V/cm Torr), on electron mobility and lifetimes in a range of gas mixtures. These mixtures included argon, methane, nitrogen and carbon dioxide. Measurements of single-electron spectra showed that, unexpectedly for the standard gas mixtures employed, useful departure from an exponential spectrum was not possible without the production of cathode secondaries. Although the present studies employed only the counter electrical signal the information obtained should be directly relevant to the operation of practical light-pulse systems. Examples of electron-counting spectra for soft X-rays are shown. (orig.).
1990-05-21
Counting characteristics of X-ray detectors fabricated from indium-doped, gallium-doped, and chlorine-doped CdTe have been investigated. The detectors fabricated from indium-doped and gallium-doped crystals showed radiation-induced polarization, namely, a progressive decrease of count rate with an increase of photon fluence in the high-photon-fluence region, while the detectors fabricated from chlorine-doped crystals did not. Results from current-voltage characteristics of the detectors indicated that the different counting characteristics of these detectors originated from the difference in internal electric fields in each detector.
1995-08-01
British Library Electronic Table of Contents (United Kingdom)
Research on hematological disorders relies on suitable animal models. We retrospectively evaluated the use of the hematological parameters hematocrit (HCT), hemoglobin (HGB), mean corpuscular hemoglobin (MCH), mean corpuscular hemoglobin concentration (MCHC), mean corpuscular volume (MCV), red blood cell count (RBC), white blood cell count (WBC), and platelet count (PLT) in the phenotype-driven Munich N-ethyl-N-nitrosourea (ENU) mouse mutagenesis project as parameters for the generation of novel animal models for human diseases. The analysis was carried out on more than 16,000 G1 and G3 offspring of chemically mutagenized inbred C3H mice to detect dominant and recessive mutations leading to deviations in the levels of the chosen parameters. Identification of animals exhibiting altered valu...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Applying a total energy absorption {gamma}-ray detector composed of 12 bricks (5x5 cm{sup 2}, 7.5 cm thick) of Bi{sub 4}Ge{sub 3}O{sub 12}(BGO) scintillators, the absolute measurement of capture cross sections for Au and Sb has been made in an energy region between 0.01 eV and 10 eV using the linac time-of-flight method. Incident thermal neutron flux was absolutely determined by using the BGO detection system with a Sm sample. To extend the neutron flux measurement from the thermal neutron region to higher neutron energy, the {sup 10}B(n, {alpha} {gamma}) reaction was applied. Absolute capture yield for the relevant capture sample was obtained by the saturated capture yield at a large resonance of the sample. Gold was selected to investigate the application of the BGO detection system to the absolute measurement of the capture cross sections, since the {sup 197}Au(n, {gamma}){sup 198}Au reaction cross ...
1997-07-01
Environmental Research Database
ObjectivesThe overall aim of the proposed research is explicit in the project title, i.e. the creation of a map of current vertical land movements in the UK based on an optimal combination of absolute gravity (AG) and continuous GPS (CGPS). This is consistent with specific objective (ii) of WP1.9 of the Oceans 2025 programme and is related to priority topic area 4 (application of satellite geodesy to sea level science) of the NERC Strategic Ocean Funding Initiative (SOFI). From long term geological an [continued...]DescriptionThe proposed research aims to create a map of current vertical land movements in the UK based on an optimal combination of estimates from two geodetic surveying and monitoring techniques; the measurement of absolute gravity (AG) and the use of high precision, continuous GPS (CGPS) observations. From long term geological and geophysical studies, vertical land movements in the UK are thought to be of the order of 1 to 2 ...
2009-01-31
International Nuclear Information System (INIS)
A merged-beams electron-energy-loss technique is described, by which absolute cross sections can be measured for near-threshold electron-impact excitation of multipy charged ions. Results are reported here for absolute total electron-impact excitation cross sections for the O"5"+(2s#->#2p) transition from below threshold to 1.6 eV above threshold. The experimental data are in good agremeent with a seven-state close-coupling calculation throughout the energy range of the experiment. Results agree with calculations showing that more than 90% of the electrons causing excitation are ejected in the backward direction in the center-of-mass frame. This backscattering is shown in both quantum-mechanical and semiclassical calculations. Evidence is observed for high-lying metastable autoionizing states with a lifetime of approximately 0.9 #mu#s which are made to ionize by electron impact.
UK PubMed Central (United Kingdom)
An improved method of counting acoustic emission (AE) events from water-stressed stems of cedar (Thuja occidentalis L.) is presented. Amplified AEs are analyzed on a real time basis...Full Text Available
1984-04-01
UK PubMed Central (United Kingdom)
The purpose of this study was to examine relationships between weather and outdoor physical activity (PA). An online weather source was used to obtain daily max temperature [DMT], precipitation, and...Full Text Available
2011-02-01
Risk factors for thrombosis in lupus patients.
UK PubMed Central (United Kingdom)
Lupus anticoagulant, concentrations of anticardiolipin antibodies, antithrombin III, plasminogen, (free) protein S, protein C, prothrombin, platelet counts, and bleeding times were determined in 74...Full Text Available
1989-11-01
International Nuclear Information System (INIS)
This work improves the reliability and accuracy in the reconstruction of the total isotope activity content in heterogeneous nuclear waste drums containing point sources. The method is based on #chi#"2-fits of the angular dependent count rate distribution measured during a drum rotation in segmented gamma scanning. A new description of the analytical calculation of the angular count rate distribution is introduced based on a more precise model of the collimated detector. The new description is validated and compared to the old description using MCNP5 simulations of angular dependent count rate distributions of Co-60 and Cs-137 point sources. It is shown that the new model describes the angular dependent count rate distribution significantly more accurate compared to the old model. Hence, the reconstruction of the activity is more accurate and the errors are considerably reduced that lead to more ...
2011-06-01
Energy Technology Data Exchange (ETDEWEB)
Thirty-four patients with prostatic carcinoma were studied with quantitative bone scintigraphy and whole-body counting (WBC) 1 and 24 h after injection of [sup 99m]Tc-MDP before as well as two weeks and two months after orchiectomy. Thirteen of the patients had normal bone scintigrams and WBR at the three different investigations; 21 had skeletal metastases. The latter showed throughout the study higher local gamma camera count rates as well as WBR values than the patiens with normal scintigrams. In these patients a ''flare phenomenon'', with an increase in count rate two weeks after orchiectomy followed by a decrease two months post-operatively, was seen with quantitative bone scintigraphy but not with WBC. However, WBC may be a valuable method indicating the total extent of skeletal metastases in the body, while quantitative bone scintigraphy is more accurate in the interpretation of ...
1992-10-01
International Nuclear Information System (INIS)
Thirty-four patients with prostatic carcinoma were studied with quantitative bone scintigraphy and whole-body counting (WBC) 1 and 24 h after injection of "9"9"mTc-MDP before as well as two weeks and two months after orchiectomy. Thirteen of the patients had normal bone scintigrams and WBR at the three different investigations; 21 had skeletal metastases. The latter showed throughout the study higher local gamma camera count rates as well as WBR values than the patiens with normal scintigrams. In these patients a ''flare phenomenon'', with an increase in count rate two weeks after orchiectomy followed by a decrease two months post-operatively, was seen with quantitative bone scintigraphy but not with WBC. However, WBC may be a valuable method indicating the total extent of skeletal metastases in the body, while quantitative bone scintigraphy is more accurate in the interpretation of individual skeletal metastases. (orig.).
Lessons Learned, Headquarters, 25th Infantry Division ...
... Contact was broken at 1628 hours -n! f1r1 again at 1730 hours. ... wore_ 5 US KIA and 14 WI... 13 VC bexly count by air and ground tro~ps rusultod-. ...
1970-02-20
UK PubMed Central (United Kingdom)
BackgroundMuch of our current understanding of the epidemiology of Ascaris lumbricoides infections in humans has been acquired by analyzing worm count data. These...Full Text Available
First Measurements of the Inclined Boron Layer Thermal-Neutron Detector for Reflectometry
Energy Technology Data Exchange (ETDEWEB)
A prototype detector based on the inclined boron layer principle is introduced. For typical measurement conditions at the Liquids Reflectometer at the Spallation Neutron Source, its count rate capability is shown to be superior to that of the current detector by nearly two orders of magnitude.
2010-01-01
First Measurements of the Inclined Boron Layer Thermal-Neutron Detector for Reflectometry
Energy Technology Data Exchange (ETDEWEB)
A prototype detector based on the inclined absorber layer principle is introduced. For the Liquids Reflectometer at the Spallation Neutron Source, it is shown to be a significant improvement over its current detector, which imposes an instantaneous count rate limitation of 50 kcps.
2008-10-01
Feynmann variance-to-mean method
Energy Technology Data Exchange (ETDEWEB)
The Feynmann and other fluctuation techniques have been shown to be useful for determining the multiplication of subcritical systems. The moments of the counting distribution from neutron detectors is analyzed to yield the multiplication value. We present the methodology and some selected applications and results and comparisons with Monte Carlo calculations.
1985-01-01
Dynamic quantitative bone scintigraphy in patients with prostatic carcinoma treated by orchiectomy
International Nuclear Information System (INIS)
Dynamic quantitative bone scintigraphy was performed on 31 men with prostatic carcinoma before orchiectomy as well as 2 weeks, 2 and 6 months postoperatively. After injection of technetium methylene diphosphonate Tc 99m ("9"9"mTc-MDP) the count rate was recorded as serial images over the lower thoracic and all the lumbar vertebrae from 1 to 240 min post-injection. Thirteen men had normal bone scintigrams with no changes in "9"9"mTc-MDP content at the four different investigation times. Eighteen men had skeletal metastases. Throughout the study half of the abnormal vertebrae in these patients showed an abnormal count rate after only 6 min post-injection. After 1 h it was possible in almost all abnormal vertebrae to predict abnormal bone uptake. In response to therapy a 'flare phenomenon' with an increase in count rate was seen 2 weeks after orchiectomy followed by a decrease 2 months postoperatively in most of the abnormal ...
Energy Technology Data Exchange (ETDEWEB)
Marketing of minimally processed vegetables (MPV) are gaining impetus due to its convenience, freshness and apparent health effect. However, minimal processing does not reduce pathogenic microorganisms to safe levels. Food irradiation is used to extend the shelf life and to inactivate food-borne pathogens. In combination with minimal processing it could improve safety and quality of MPV. A microbiological screening method based on the use of direct epifluorescent filter technique (DEFT) and aerobic plate count (APC) has been established for the detection of irradiated foodstuffs. The aim of this study was to evaluate the applicability of this technique in detecting MPV irradiation. Samples from retail markets were irradiated with 0.5 and 1.0 kGy using a {sup 60}Co facility. In general, with a dose increment, DEFT counts remained similar independent of the irradiation while APC counts decreased gradually. The difference of ...
2009-07-15
An Aggregate Dynamic Stochastic Model for an Air Traffic System
processes, we construct a stochastic dynamic model for air- craft counts in ... Also , queueing models for the arrival of aircraft at ... A queueing model has also been used to study ...... Assignment and Aircraft-Sequencing Algorithms in Terminal ...
UK PubMed Central (United Kingdom)
BackgroundPlotless density estimators are those that are based on distance measures rather than counts per unit area (quadrats or plots) to estimate the density of some usually stationary...Full Text Available
The effects of packaging materials on microbe population in irradiated traditional herbal medicines
International Nuclear Information System (INIS)
Microbial population and moisture content of traditional herbal medicines contaminated with 3 kinds of aerobic microbes, packed in 5 kinds of plastic packaging materials, followed by irradiation at minimum dose of 5 kGy and stored for 6 months were investigated. The highest reduction of microbial counts during storage was observed on samples packed in polyethylene bags. All of packaging materials used were found to be impermeable to microbes and water vapour. Radiation and packaging materials used acted synergistically to inactivate microbes durind storage. The microbial counts decreased as much as 2 to 4 log cycles during storage. (author).
Quantitative bone scintigraphy in the evaluation of angular deformity of the lower extremity
International Nuclear Information System (INIS)
A technique for quantitative analysis of growth plates in varus or valgus deformity about the knee has been developed. Computer-generated regions of interest are placed on magnification scintigraphs to divide distal femoral and proximal tibial physes into four equal segments. The ratio of counts in the medial half to counts in the lateral half was studied in 31 children (22 normal, 9 with angular deformity). Normal ratios were 0.74 to 0.98 for femora and 0.98 to 1.20 for tibias. In eight of nine patients with deformity, the ratio was abnormal; in two patients the ratio returned to normal when the deformity ceased to progress.
Performance optimization of the Packard 2000 CA/LL liquid scintillation counter for "1"4C dating
International Nuclear Information System (INIS)
The ability of the Packard 2000 CA/LL liquid scintillation counter to reduce background count rates relies on pulse shape/duration analysis in which short duration organic scintillation events are discriminated from longer duration non-quenchable background events. A consequence of this is a loss in the counting efficiency. The results of this investigation indicate that much of the lost efficiency can be regained by sharpening the true #beta#"- pulse widths via the use of different scintillant combinations and by certain counter modifications. (author).
Nuclear borehole logging using lithium detector assemblies
International Nuclear Information System (INIS)
A method and apparatus for nuclear borehole logging, and in particular, neutron porosity logging, uses a neutron source, and a pair of spaced lithium detectors, preferably Li"6I crystal or Li"6 doped glass, to detect neutrons emitted from a borehole formation being logged. The spectrum developed by the lithium detectors is processed to remove the gamma ray background radiation and the hydrogen absorption peak, thus allowing a more accurate neutron count. A Gaussian curve is fitted to the neutron peak of the spectrum, the curve eliminating the hydrogen absorption peak. The area under this Gaussian curve represents the neutron count. (author).
1991-11-01
Environmental Research Database
SummaryBTO Winter Gull Roost Survey (WinGS): 2004/07. To assess the significance of Northern Ireland gull populations Background The BTO has organised national surveys of winter gull roosts each decade since 1953 in order to estimate numbers of wintering gulls. The last survey took place in January 1993, during which over 2.5 million gulls were counted in Great Britain. A further 19,000 gulls were also counted in Northern Ireland, 3,850 in the Isle of Man and 8,500 in the Channel Islands. (The re [continued...
A review of the probabilistic aspects of localized corrosion
Energy Technology Data Exchange (ETDEWEB)
Localized corrosion has a stochastic character by nature. This character leads to an observed random behavior: fluctuations of the free potential, fluctuations of the current when a constant potential is maintained. This random signal, which is similar to an electric noise, can be analyzed either in the time domain by counting the events or in the frequency domain by measuring the power spectral density of the electrochemical noise. The experimental techniques developed for investigating the localized corrosion on the probabilistic point of view, i.e., statistical counting and power spectral density measurements, are discussed. Then the experimental results reported in the literature are reviewed in order to see what kind of parameters are accessible and how they can be related to the localized corrosion processes.
1990-04-01
A new method for sealing containers with liquid samples for radioactivity measurements
International Nuclear Information System (INIS)
It is imperative to use a leak-proof container for counting liquid sample to prevent contamination of costly gamma detectors. A sealant that ensures no leak is reported. It is a vinyl adhesive sealant used for household purposes, marketed by Gloucester Co., Inc, Franklin, MA under the trade name of Phenoseal (translucent variety). This sealant was superior to other sealants studied because it cures quickly, peels off easily after counting, and contains no detectable radioactivity. This sealant has been thoroughly tested and successfully employed it in the routine analysis of environmental liquid samples. (author)
2002-08-01
Energy Technology Data Exchange (ETDEWEB)
New York City data indicate that seasonal and annual variations in dispersion-normalized air pollutant concentrations appear to accurately reflect changes in source emission patterns. The normalized concentrations make it possible to observe the impact of regulatory changes on ambient air quality without these impacts being obscured by meteorological fluctuations. It is found that numerical modeling techniques and regression analysis can be powerful tools for extracting information from large sets of air quality data. The use of differential, as opposed to absolute, pollutant concentration values will reduce artifact correlations caused by seasonal, weekly, or daily meteorological fluctuations and will permit more accurate estimation of the regression coefficients. This technique was successfully applied to a set of daily pollution measurements whose absolute concentrations were found not to yield a statistically significant fit by multiple ...
1980-01-01
International Nuclear Information System (INIS)
New York City data indicate that seasonal and annual variations in dispersion-normalized air pollutant concentrations appear to accurately reflect changes in source emission patterns. The normalized concentrations make it possible to observe the impact of regulatory changes on ambient air quality without these impacts being obscured by meteorological fluctuations. It is found that numerical modeling techniques and regression analysis can be powerful tools for extracting information from large sets of air quality data. The use of differential, as opposed to absolute, pollutant concentration values will reduce artifact correlations caused by seasonal, weekly, or daily meteorological fluctuations and will permit more accurate estimation of the regression coefficients. This technique was successfully applied to a set of daily pollution measurements whose absolute concentrations were found not to yield a statistically significant fit by multiple ...
Typically, point forecasting methods are compared and assessed by means of an error measure or scoring function, such as the absolute error or the squared error. The individual scores are then averaged over forecast cases, to result in a summary measure of the predictive performance, such as the mean absolute error or the (root) mean squared error. I demonstrate that this common practice can lead to grossly misguided inferences, unless the scoring function and the forecasting task are carefully matched. Effective point forecasting requires that the scoring function be specified ex ante, or that the forecaster receives a directive in the form of a statistical functional, such as the mean or a quantile of the predictive distribution. If the scoring function is specified ex ante, the forecaster can issue the optimal point forecast, namely, the Bayes rule. If the forecaster receives a directive in the form of a functional, it is critical that the ...
2009-01-01
International Nuclear Information System (INIS)
Measurements of absolute differential cross sections for H"+-H_2 direct, single-, and double-charge-transfer scattering at 0.5, 1.5, and 5.0 keV are reported at laboratory scattering angles less than 1 degree with an angular resolution of approximately 0.02 degree. The cross sections exhibit deep interference oscillations in single-charge-transfer scattering, but no such oscillations are present in direct and double-charge-transfer scattering. Theoretical cross sections derived using the diatoms-in-molecules method to describe the molecular states in a semiclassical molecular-orbital three-state close-coupling model within a semiclassical framework agree satisfactorily with the experimental results.
Using data from atmospheric neutrino mixing, and a simple functional form for mixing angles, the absolute values of three neutrino masses are calculated: $m_3\\cong 5.37\\times 10^{-2} eV$, $m_2\\cong 1.94\\times 10^{-2} eV$, $m_1\\cong 1.46\\times 10^{-2} eV$. The quantities relevant for solar neutrino mixing are calculated: $(m_2^2-m_1^2) \\cong 1.63\\times 10^{-4} eV^2$, with non-maximal mixing $\\tan^2\\theta_\\sol \\cong 0.56$. The analysis gives a suggestion of a dynamical origin for the empirical, large CP-violating phase associated with an intrinsically, very small mixing angle in the quark sector.
2003-01-01
International Nuclear Information System (INIS)
This paper reports measurements of absolute differential cross sections for electron capture and loss for fast hydrogen atoms incident on H_2, N_2, O_2, Ar, and He. Cross sections have been determined in the 2.0- to 5.0-keV energy range over the laboratory angular range 0.02 degree--2 degree, with an angular resolution of 0.02 degree. The high angular resolution allows us to observe structure at small angles in some of the cross sections. Comparison of the present results with those of other authors generally shows very good agreement.
International Nuclear Information System (INIS)
Absolute total cross sections for electron-impact excitation of the 3s"2"1S#->#3s3p"3P and 3s"2"1S#->#3s3p"1P transitions in Si"2"+ were measured using the merged electron-ion beams energy-loss technique. The results are compared to R-matrix close-coupling theory, which predicts a strong resonance enhancement of the cross section near the threshold for excitation of the "3P state and this is confirmed by the experiments. The observed disagreement between theory and experiment for the dipole excitation is suggested to be due to resonance interference. copyright 1997 The American Physical Society.
The ability of Yersinia pestis to forestall the mammalian innate immune response is a fundamental aspect of plague pathogenesis. In this study, we examined the effect of Ail, a 17-kDa outer membrane protein that protects Y. pestis against complement-mediated lysis, on bubonic plague pathogenesis in mice and rats. The Y. pestis ail mutant was attenuated for virulence in both rodent models. The attenuation was greater in rats than in mice, which correlates with the ability of normal rat serum, but not mouse serum, to kill ail-negative Y. pestis in vitro. Intradermal infection with the ail mutant resulted in an atypical, subacute form of bubonic plague associated with extensive recruitment of polymorphonuclear leukocytes (PMN or neutrophils) to the site of infection in the draining lymph node and the formation of large purulent abscesses that contained the bacteria. Systemic spread and mortality were greatly attenuated, however, and a productive adaptive immune ...
2011-10-01
British Library Electronic Table of Contents (United Kingdom)
To evaluate the role and the prognostic value of bronchoalveolar lavage (BAL) in scleroderma patients with interstitial lung disease. We reviewed the records of 79 patients with systemic sclerosis (SSc) who had dyspnea and pulmonary involvement and underwent BAL study. Sixty-two patients were prospectively followed up for 12?36?months and re-evaluated by pulmonary function tests (PFTs). Seventy-nine SSc patients were enrolled (71 F and 8?M), 55 with limited and 24 with a diffuse form; mean age 55???13?years; mean disease duration 55.2???59?months. All patients were ANA positive, of these 30 were anti-topoisomerase-1 positive (anti-Topo1) and 22 were anti-centromere positive (ACA). Thirty-one patients had alveolitis (39.2%) that was neutrophilic in 12 patients, eosinophilic in 3 and mixed (...
2011-01-01
Tachyons imply the existence of a privileged frame
Energy Technology Data Exchange (ETDEWEB)
It is shown that the existence of faster-than-light signals (tachyons) would imply the existence (and detectability) of a privileged inertial frame and that one can avoid all problems with reversed-time order only by using absolute synchronization instead of the standard one. The connection between these results and the EPR-paradox is discussed.
1985-12-16
British Library Electronic Table of Contents (United Kingdom)
A novel class of pyrrolidinyl-acetyleneic thieno[3,2-d]pyrimidines has been identified which potently inhibit the EGFR and ErbB-2 receptor tyrosine kinases. Synthetic modifications of the pyrrolidine carbamate moiety result in a range of effects on enzyme and cellular potency. In addition, the impact of the absolute stereochemical configuration on cellular potency and oral mouse pharmacokinetics is described.
2009-01-01
Significance of cranial computer tomography for the early diagnosis of peri- and postnatal damage
Energy Technology Data Exchange (ETDEWEB)
It is reported on examination-technical possibilities with craniocerebral Computer Tomography in the peri- and postnatal period. Some typical tomographic images from a 17 1/2 months period in our own patient material of 327 children are demonstrated. The special advantages of this new technical-extensive method are: exact diagnoses, observation possibility of the longitudinal section, and the absolute harmlessness to the child.
1981-01-01
Joanna Geary joined a Birmingham University team of scientists working on the project in Geneva. Simond Hadley took the pictures. "The most exciting thing of all" says professor Peter Watkins with a smile, "is we have absolutely no idea what will happen until we switch it on."
2008-01-01
Quantum Cloning for Absolute Radiometry
International Nuclear Information System (INIS)
In the quantum regime information can be copied with only a finite fidelity. This fidelity gradually increases to 1 as the system becomes classical. In this Letter we show how this fact can be used to directly measure the amount of radiated power. We demonstrate how these principles can be used to build a practical primary standard.
2010-08-20
UK PubMed Central (United Kingdom)
An assay method is described for measurement of absolute concentrations of the molybdenum cofactor, based on complementation of the defective nitrate reductase ('apo nitrate reductase') in extracts...Full Text Available
1984-04-15
Monitoring for Xenon Radionuclides and CTBT Verification
International Nuclear Information System (INIS)
The Comprehensive Nuclear-Test-Ban-Treaty (CTBT), which was opened for signature in 1996, bans all nuclear explosions in all environments. Republic of Korea has been working to monitor compliance with CTBT by deterring and detecting any nuclear explosions conducted anywhere on Earth. For the verification of CTBT, several techniques are implemented. Radionuclide monitoring is of particular importance since it is the only method which can provide absolute assurance that a nuclear detonation has occurred
2010-10-01
Mediation of bone ingrowth in porous hydroxyapatite bone graft substitutes.
Previous investigations have shown that both the early biological response and the mechanical properties of a porous hydroxyapatite bone graft substitute are highly sensitive to its pore structure. The objective of this study was to evaluate whether the pore structure continued to influence bone integration in the medium to long term. Two screened batches of porous hydroxyapatite (PHA) designated as batch A and batch B, with porosities of approximately 60 and 80%, respectively, were selected for this study and implanted for periods of 5, 13, and 26 weeks into the lower femur of New Zealand White rabbits. Histomorphometric analysis of the absolute volume of bone ingrowth within batch A and B implants from 5 to 26 weeks showed that the absolute volume of bone ingrowth was consistently lower in batch A (10-21%), compared to batch B implants (24-31%). However, when the volume of bone ingrowth was normalised for the available pore space, this ...
2004-01-01
Frequency evaluation of the doubly forbidden $^1S_0\\to ^3P_0$ transition in bosonic $^{174}$Yb
We report an uncertainty evaluation of an optical lattice clock based on the $^1S_0\\leftrightarrow^3P_0$ transition in the bosonic isotope $^{174}$Yb by use of magnetically induced spectroscopy. The absolute frequency of the $^1S_0\\leftrightarrow^3P_0$ transition has been determined through comparisons with optical and microwave standards at NIST. The weighted mean of the evaluations is $\
2008-01-01
Estimates of Amplitudes of Transient Regimes in Quasi-Controllable Discrete Systems
Families of regimes for discrete control systems are studied possessing a special quasi-controllability property that is similar to the Kalman controllability property. A new approach is proposed to estimate the amplitudes of transient regimes in quasi-controllable systems. Its essence is in obtaining of constructive a priori bounds for degree of overshooting in terms of the quasi-controllability measure. The results are applicable for analysis of transients, classical absolute stability problem and, especially, for stability problem for desynchronized (asynchronous, switching) systems.
2009-01-01
Determination of the performance of explosives
Energy Technology Data Exchange (ETDEWEB)
The author attempts to calculate the absolute characteristics of explosives unrelated to the effects of environment, particularly for that part of the work of the explosion done by the expansion of the detonation products. Setting forth his equations and noting their agreement with experimental data, he concludes that for a complete characterization of the relative effectiveness of explosives it is necessary to know the pressure, mass velocity, and polytropic index of the detonation products, but that developed considerations of the relation between performance and detonation characteristics permit a more exact evaluation of various explosives and unification of the nomenclature of explosives and methods of testing them.
1984-11-01
Biological effects and health risks following to the exposition to ionizing radiation
International Nuclear Information System (INIS)
Late somatic and genetic radiation effects are imperfectly understood, particularly in the human species. However the available information is sufficient to draw reasonably precise risk estimates in man for many types of damage by means of scientifically justifiable procedures and with the necessary caution. This overall absolute risk of major somatic and genetic damage may be set at around 10"-"4/rad of chronic whole-body doses.
1976-01-01
A study of the Baldwin effect in the IUE data set
The paper investigates the controversial relation between the continuum luminosity and the C IV 1550 emission-line strength in the spectra of quasars, commonly referred to as the Baldwin effect, as a possible indicator of absolute luminosity. It is concluded that the Baldwin effect does represent a physical correlation between the continuum and the C IV 1550 equivalent width rather than a consequence of selection effects. In addition to the C IV results, a similar relation is found for the Lyman-alpha emission line. 38 refs.
1990-07-01
A nonlinear model for DNA dynamics
In this paper the thermal equilibrium number of solitons in DNA as a function of absolute temperature and the number of base pairs is calculated. These calculations are effected by modeling DNA as a Toda lattice with parameters chosen to match experimentally measured properties of DNA. It is found that a significant number of solitons is generated at physiological temperature. 23 refs., 2 figs.
1989-07-01
International Nuclear Information System (INIS)
The purpose of this study is to investigate the possibility of verifying depleted uranium (DU), natural uranium (NU), low enriched uranium (LEU) and high enriched uranium (HEU) by a developed digital gamma-gamma coincidence spectroscopy. The spectroscopy consists of two NaI(Tl) scintillators and XIA LLC Digital Gamma Finder (DGF)/Pixie-4 software and card package. The results demonstrate that the spectroscopy provides an effective method of "2"3"5U and "2"3"8U quantification based on the count rate of their gamma-gamma coincidence counting signatures. The main advantages of this approach over the conventional gamma spectrometry include the facts of low background continuum near coincident signatures of "2"3"5U and "2"3"8U, less interference from other radionuclides by the gamma-gamma coincidence counting, and region-of-interest (ROI) imagine analysis for uranium enrichment determination. Compared to conventional gamma ...
2011-06-01
Energy Technology Data Exchange (ETDEWEB)
This report compares the performance characteristics of /sup 10/B-lined and fission-neutron detectors in gamma-ray fluxes typical of the fields to be encountered during nondestructive testing of irradiated light-water fuel assemblies stored in water. Using the optimum time constants for each of the /sup 10/B-lined detectors, the 0.25-in.-dia detector had a 5% loss in neutron count sensitivity at 7000 rad/h. Similarly, the 0.5-in.-dia detector had a 7% loss at 13,000 rad/h and the 1-in.-dia detector had a 5% loss in sensitivity at 1000 rad/h. Uranium-235 fission chambers were operated successfully in fields above 100,000 rad/h with no loss in neutron counting sensitivity. Shielding calculations were done to determine the appropriate shield thickness needed for a /sup 10/B-lined neutron detector to operate in a 50,000 rad/h field, typical of light-water-reactor spent-fuel assemblies stored in water. 7 refs., 4 figs., 9 tabs.
1985-03-01
Comparison of newer synthetic and biological wound dressings.
In 18 piglets, weighing 10-15 kg, third-degree burns or full-thickness skin excisions of 4 X 4 cm were inflicted. The effect of five dressing materials on adhesiveness to the wounds, appearance, conformability, wound contraction, bacterial count, and morphology of the wound was studied at the end of the seventh and fourteenth days without dressing changes. In 11 piglets with a burn wound, the most adherent dressing was collagen sponge(CS), followed by polyurethane sponge (PU), pigskin xenograph (PS), and xeroform. CS more effectively debrided the wound from coagulated necrotic tissue than the other dressings. Wound contraction was maximal with CS dressing (52%), followed by PU (44%), xeroform (32%), and PS (27%). In another seven piglets with full-thickness excised wounds, a velour dressing made of polytetrafluoroethylene (PTFE) or PU adhered significantly more than CS or PS. Wound contraction was greater with CS (37%) or PTFE (35%) than with PS (23%) or PU (18%). ...
1981-06-01
Energy Technology Data Exchange (ETDEWEB)
This project was supported through ERDA to demonstrate that the temporal distribution of tritium can be documented by the analysis of bound hydrogen in annual tree-ring samples. The project focuses on two sample locations at the Savannah River Site (SRS), a nuclear material production facility located in Aiken, SC. The SRS provided samples of cross-sections from a single tree that were to be pooled together for analysis. Annual tree-rings were identified in each cross-section sample and separated for the period 1954 to 1993. These annual samples were ground and chemically treated to separate the hollocellulose fraction of the wood, then subsequently combusted and the resulting water counting using low-level liquid scintillation counting equipment. Additionally, the ground annual tree-rings were gamma-counted to determine any temporal variation in radionuclide activity and analyzed with x-ray fluorescence to find any ...
1995-03-21
Reborn quadrant anode image sensor
International Nuclear Information System (INIS)
We describe a position sensitive photon counting microchannel plate based detector with an improved quadrant anode (QA) readout system. The technique relies on a combination of the four planar elements pattern and an additional fifth electrode. The charge cloud induced by single particle detection is split between the electrodes. The measured charge values uniquely define the position of the initial event. QA has been first published in 1976 by Lampton and Malina. This anode configuration was undeservedly forgotten and its potential has been hardly underestimated. The presented approach extends the operating spatial range to the whole sensitive area of the microchannel plate surface and demonstrates good linearity over the field of view. Therefore, the novel image sensor results in spatial resolution better then 50?m and count rates up to one million events per second.
2009-06-01
British Library Electronic Table of Contents (United Kingdom)
This paper presents the first report of multiple anthelmintic resistance in the gastrointestinal nematodes of goats and its possible contributory factors in an irrigated area (Pakistan). A total of 18 privately owned Beetal goat flocks were selected in order to determine the anthelmintic resistance against commonly used anthelmintics. Forty to 48 animals from each flock were selected according to their weight and egg count. The three anthelmintics viz., oxfendazole, levamisole and ivermectin, were given to three groups at manufacturer's recommended dose while one group was kept as untreated control. Anthelmintic resistance was determined through faecal egg count reduction and egg hatch tests while assessment of the contributory factors of anthelmintic resistance was measured through the ru...
2010-01-01
Selenium 79 is a beta emitter produced from (235)U fission and is one of the long half-life radionuclides of interest in nuclear waste disposal problematic because of its potential migration capacity to the surface environment. Measurement of (79)Se is particularly difficult due to its low activity in waste matrices (about 10(-3)Bqg(-1)). A radiochemical procedure based on ion exchange separations was already described in a previous paper. This work presents different applications of the radiochemical separation to waste samples and an improvement of this procedure, including a selective extraction of selenium as diethylselenium in an organic solvent followed by a re-extraction in aqueous medium. This additional step allows the decontamination factor to be increased with the aim of counting (79)Se by liquid scintillation counting. PMID:19071740
2007-01-14
International Nuclear Information System (INIS)
The phase separation of (water + salt + polyethylene glycol 15000) systems was studied by cloud-point measurements using the particle counting method. The effect of three kinds of sulphate salt (Na2SO4, K2SO4, (NH4)2SO4) concentration, polyethylene glycol 15000 concentration, mass ratio of polymer to salt on the cloud-point temperature of these systems have been investigated. The results obtained indicate that the cloud-point temperatures decrease linearly with increase in polyethylene glycol concentrations for different salts. Also, the cloud points decrease with an increase in mass ratio of salt to polymer.
2009-07-01
A urine leukocyte count of > or = 50/mm3 together with a bacterial count of > or = 10(5) colony-forming units (CFUs) per milliliter was used to define significant infection in 160 children with neurogenic bladder and evaluate the leukocyte and nitrite components of the Chemstrip 9 test. A Chemstrip 9 leukocyte reading of or = 500 leukocytes together with a positive nitrite reaction occurred in 18 children and had a sensitivity of 40% with a 100% positive predictive value for infection. Other combinations of Chemstrip 9 leukocyte and nitrite reactions were unhelpful or of uncertain value. Selection of up to three specimens from each patient increased the number of samples to 360 and provided general confirmation of the above conclusions. Nitrofurantoin may reduce the sensitivity of the nitrite strip reaction. PMID:8359003
1993-07-01
Vacuum ultraviolet radiometry of xenon positive column discharges
Energy Technology Data Exchange (ETDEWEB)
In order to judge the potential fluorescent lamp applications of various low-pressure positive column discharges it is necessary to measure the absolute power emitted in the ultraviolet region of the spectrum. For rare-gas discharges the principle emission occurs in the vacuum ultraviolet so that it is difficult to measure the radiant emittance (power per unit area) of the resonance radiation by standard methods. Two independent techniques are discussed for measuring the radiant emittance of positive column discharges in the vacuum ultraviolet. These techniques are used to study xenon positive column discharges at the resonance wavelength of 147 nm. The first method relies on the measurement of the resonance level density by absorption techniques. The effective decay rate of the resonance level is then determined by the simulation of resonance radiation transport. These two quantities are combined to yield the radiant emittance at 147 nm without implementing vacuum ...
1995-10-01
Tuning PID and FOPID Controllers using the Integral Time Absolute Error Criterion
Particle swarm optimization (PSO) is extensively used for real parameter optimization in diverse fields of study. This paper describes an application of PSO to the problem of designing a fractional-order proportional-integral-derivative (FOPID) controller whose parameters comprise proportionality constant, integral constant, derivative constant, integral order (lambda) and derivative order (delta). The presence of five optimizable parameters makes the task of designing a FOPID controller more challenging than conventional PID controller design. Our design method focuses on minimizing the Integral Time Absolute Error (ITAE) criterion. The digital realization of the deigned system utilizes the Tustin operator-based continued fraction expansion scheme. We carry out a simulation that illustrates the effectiveness of the proposed approach especially for realizing fractional-order plants. This paper also attempts to study the behavior of fractional PID controller ...
2008-01-01
Energy Technology Data Exchange (ETDEWEB)
Carboxyl in coal was focused in discussing its pyrolytic behavior while tracking change of its absolute amount relative to the heating temperatures. A total of four kinds of coals, consisting of two kinds brown coals, sub-bituminous coal and bituminous coal were used. Change in the absolute amount of carboxyl due to heating varies with coalification degree. Decomposition starts in the bituminous coal from around 300{degree}C, and is rapidly accelerated when 400{degree}C is exceeded. Carboxyls in brown coals exist two to three times as much as those in bituminous and sub-bituminous coals, of which 40% is decomposed at a temperature as low as about 300{degree}C. Their pyrolytic behavior at temperatures higher than 400{degree}C resembles that of the bituminous coal. Carboxyls consist of those easy to decompose and difficult to decompose. Aromatic and aliphatic carboxylic acids with simple structure are stable at temperatures lower than ...
1996-10-28
The composite absolute penalties family for grouped and hierarchical variable selection
Extracting useful information from high-dimensional data is an important focus of today's statistical research and practice. Penalized loss function minimization has been shown to be effective for this task both theoretically and empirically. With the virtues of both regularization and sparsity, the $L_1$-penalized squared error minimization method Lasso has been popular in regression models and beyond. In this paper, we combine different norms including $L_1$ to form an intelligent penalty in order to add side information to the fitting of a regression or classification model to obtain reasonable estimates. Specifically, we introduce the Composite Absolute Penalties (CAP) family, which allows given grouping and hierarchical relationships between the predictors to be expressed. CAP penalties are built by defining groups and combining the properties of norm penalties at the across-group and within-group levels. Grouped selection occurs for nonoverlapping groups. ...
2009-01-01
The millimeter microwave source of gyrotron-traveling-wave amplifier (gyro-TWT) is capable of generating high power coherent radiation in a broad bandwidth, while its performance is severely deteriorated by the stability problems. This paper focuses on modeling and the stability analysis of the Naval Research Laboratory (NRL) Ka-band TE{sub 01} mode gyro-TWT based on an interaction circuit alternately loaded with lossy ceramic shells and metal rings. The propagation characteristics of the interaction circuit is analyzed first, based on which the boundary impedance method is employed to build an equivalent uniform lossy circuit. Then the stability of the interaction system is studied using linear and nonlinear theories. The analysis reveals that, due to the special waveguide structure and the dielectric loss, the propagation characteristics of the complex waveguide are similar to that of a uniform lossy circuit. The analysis of the absolute instabilities ...
2009-07-15
International Nuclear Information System (INIS)
The millimeter microwave source of gyrotron-traveling-wave amplifier (gyro-TWT) is capable of generating high power coherent radiation in a broad bandwidth, while its performance is severely deteriorated by the stability problems. This paper focuses on modeling and the stability analysis of the Naval Research Laboratory (NRL) Ka-band TE01 mode gyro-TWT based on an interaction circuit alternately loaded with lossy ceramic shells and metal rings. The propagation characteristics of the interaction circuit is analyzed first, based on which the boundary impedance method is employed to build an equivalent uniform lossy circuit. Then the stability of the interaction system is studied using linear and nonlinear theories. The analysis reveals that, due to the special waveguide structure and the dielectric loss, the propagation characteristics of the complex waveguide are similar to that of a uniform lossy circuit. The analysis of the absolute instabilities characterizes the ...
2009-07-01
Rotating magnetic tensor gradiometry and a superconducting implementation
International Nuclear Information System (INIS)
This work describes the theoretical basis for a new concept rotating magnetic tensor gradiometer. The rotating gradiometer consists of an approximately axial or transverse gradiometer which is made to rotate about a perpendicular axis so that the direction of sensitivity is continually changing. It is demonstrated for the first time that the rotation separates gradient components of progressively higher-order in the frequency domain and enables absolute-value measurements of all components of the first-order magnetic gradient tensor, even if the magnetic sensors comprising the gradiometer are intrinsically incapable of absolute-value detection. In addition, the rotating gradiometer concept has a number of other advantages: the gradiometer imbalance is no longer directly determined by the engineering precision, the DC and low-frequency performance of the instrument is not limited by the performance of the detectors in these respects, rotation at ...
2009-07-01
Los Alamos second-generation system for passive and active neutron assays of drum-size containers
International Nuclear Information System (INIS)
We describe in a comprehensive fashion the Los Alamos second-generation system for passive and active neutron assays of drum-size containers. The developmental history of this 7-year project is presented with emphasis on the pulsed active neutron technique (differential dieaway), which has achieved milligram levels of assay sensitivity for both plutonium and uranium wastes. We describe in detail the matrix effects for both passive and active neutron assays. We present in a thorough fashion our novel approach to achieving comprehensive corrections for these matrix effects using measurements made during the assays. We develop a matrix correction formalism based on separate neutron absorption and moderator indices determined from these measurements. These are presented as a series of analytic functions fitted to the data. Absolute calibrations and calibration standards are discussed, as is a practical means (pink drum measurements) of achieving routine calibration ...
1972-09-17
International Nuclear Information System (INIS)
The KLL Auger electron spectrum of "8"8Sr generated in the EC-decay of "8"8Y has been analyzed at the instrumental resolution of 11 eV using a combined electrostatic spectrometer. Energies and relative intensities of the all nine transitions were determined and compared with theoretical predictions. Our value of 12067.3(12) eV measured for the absolute energy of the dominant KL_2L_3("1D_2) transition was found to be higher by 7.4 eV (i.e., more than 3#sigma#) than that one obtained in a measurement with external excitation. The discrepancy indicates substantial influence of the 'atomic structure effect' on absolute transition energies in our experiment. Very good agreement of the measured 0.14(3) and predicted 0.12 values for the KL_1L_2("3P_0/"1P_1) Auger transition intensity ratio clearly proved the predicted strong influence of the relativistic effects on the KL_1L_2("3P_0) transition rate even at Z = 38.
2007-08-01
Energy Technology Data Exchange (ETDEWEB)
The proposed ERICAM model exhibits deficiencies of a nature making it inacceptable to responsible governments. These deficiencies are: it does not provide the required financial security. The availability of insurance coverage will be dependent on the situation in the financial markets. Pricing will not be determined by the absolute probability of incidents causing damage, so that this may entail a distortion of allocations of resources. (orig./HP) [Deutsch] Das ERICAM Modell hat Konstruktionsmaengel, dass es sicher fuer verantwortliche Regierungen nicht in Frage kaeme, dessen Realisierung in Erwaegung zu ziehen. Die wichtigsten sind: Die benoetigte Sicherheit der Deckungsmittel ist nicht gegeben. Die Lage an den Finanzmaerkten dominiert die Verfuegbarkeit der Deckungsmittel. Die Preisbildung wird nicht durch die absolute Schadenswahrscheinlichkeit bestimmt, so dass eine Verfaelschung der Allokation von Ressourcen eintreten wuerde. (orig./HP)
1995-12-31
Absolute spacetime the twentieth century ether
All gauge theories need ``something fixed'' even as ``something changes.'' Underlying the implementation of these ideas all major physical theories make indispensable use of an elaborately designed spacetime model as the ``something fixed,'' i.e., absolute. This model must provide at least the following sequence of structures: point set, topological space, smooth manifold, geometric manifold, base for various bundles. The ``fine structure'' of spacetime inherent in this sequence is of course empirically unobservable directly, certainly when quantum mechanics is taken into account. This issue is at the basis of the difficulties in quantizing general relativity and has been approached in many different ways. Here we review an approach taking into account the non-Boolean properties of quantum logic when forming a spacetime model. Finally, we recall how the fundamental gauge of diffeomorphisms (the issue of general covariance vs coordinate conditions) raised deep ...
1999-01-01
Absolute differential cross sections for the scattering of kilo-electron-volt O atoms
International Nuclear Information System (INIS)
This paper reports measurements of absolute differential cross sections for the direct scattering of oxygen atoms by He, Ne, Ar, Kr, Xe, H_2, N_2, O_2, CO, CO_2, H_2O, SO_2, NH_3, CH_4, CF_4, and SF_6 targets. The measured cross sections include contributions from all elastic and inelastic processes that result in a fast neutral oxygen atom product. Cross sections are presented for 0.5- and 1.5-keV projectile energies over the laboratory angular range 0.2 degree endash 5 degree. When compared in the center-of-mass reference frame, these cross sections exhibit a high degree of similarity in both amplitude and angular dependence. The cross sections for N_2, CO, CO_2, and H_2O are inverted using a partial-wave analysis to yield empirical interaction potentials, which can then be used to extrapolate the measurements down to lower energies. Using these potentials, cross sections are evaluated at 0.1 keV. copyright 1996 The American Physical Society.
International Nuclear Information System (INIS)
Absolute total cross sections for electron-impact excitation of the 2s"2S#->#2p"2P transition in C"3"+ were measured from 7.35 eV to 8.45 eV using the merged electron-ion-beams energy-loss technique. The results settle the discrepancy between two previous experiments using the crossed-beams fluorescence method, being in very good agreement with the older results [P. O. Taylor, D. Gregory, G. H. Dunn, R. A. Phaneuf, and D. H. Crandall, Phys. Rev. Lett. 39, 1256 (1977)] but less so with the more recent ones [D. W. Savin, L. D. Gardner, D. B. Reisenfeld, A. R. Young, and J. L. Kohl, Phys. Rev. A 51, 2162 (1995)]. The present measurements are also in good agreement with unitarized Coulomb-Born and close-coupling calculations. copyright 1998 The American Physical Society.
Simple integral screenprinting process for selective emitter polycrystalline silicon solar cells
Energy Technology Data Exchange (ETDEWEB)
This letter describes a new simple fabrication process, developed recently for blue response'' improvement in low-cost polycrystalline silicon solar cells. A selective emitter is created by heavily doping the emitter, followed by a wet etching-back of the cell area between the fingers. An improvement up to 17 mV in {ital V}{sub oc}, 1.5 mA/cm{sup 2} in {ital J}{sub sc}, and 1% (absolute value) in {eta} is obtained. Effective phosphorus gettering, self-alignment, and application in a low-cost full screenprinting technology are the main advantages of the proposed process.
1991-09-23
Redox potential measurement in the power station
Energy Technology Data Exchange (ETDEWEB)
By its very nature redox potential measurement is suitable for determining the concentration ratio of a stable redox pair through its interaction with a chemically inert electrode surface but not the absolute concentration of a material. The measured redox potentials agree only rarely with those which are easily calculable theoretically. No individual defined stable redox pair is available in power station water. It is therefore not simply possible to measure definable mixed potentials more precisely. For these reasons redox potential measurement in the power station, as also with other types of water, can no longer be regarded as an indicator, by which it can be established whether oxidizing or reducing materials predominate in the water.
1983-01-01
Redox potential measurement in the power station
International Nuclear Information System (INIS)
By its very nature redox potential measurement is suitable for determining the concentration ratio of a stable redox pair through its interaction with a chemically inert electrode surface but not the absolute concentration of a material. The measured redox potentials agree only rarely with those which are easily calculable theoretically. No individual defined stable redox pair is available in power station water. It is therefore not simply possible to measure definable mixed potentials more precisely. For these reasons redox potential measurement in the power station, as also with other types of water, can no longer be regarded as an indicator, by which it can be established whether oxidizing or reducing materials predominate in the water. (orig.).
Procyon 1. First prototype worldwide for storage spent nuclear fuel rods
International Nuclear Information System (INIS)
HFH Herbst has designed and built a unique machine for storage of spent highly radioactive nuclear fuel rods within two years for the Swedish SKB. The vehicle (total weight 98 t) can be operated underground without a driver. Herbst was able to bring to this project almost 30 years of experience in the complementation of vehicle projects for the nuclear industry. The Procyon 1 already proved its efficiency impressively in several hundred storage processes and operates with absolute reliability. (orig.)
2010-05-01
Preparation of flame resistant fibers from polyacrylonitrile fibers
Energy Technology Data Exchange (ETDEWEB)
In this article, a continuous stabilization process was used to make flame resistant fibers from polyacrylonitrile (PAN) fibers. The effect of the stabilization time and the stretching process during the stabilization process on the physical properties and flammability of the resultant flame resistant fibers was studied. Increased drawing of PAN fibers during the continuous stabilization process was found to decrease the diameter and increase the tensile strength in the resultant flame resistant fibers. These fibers also had higher density. There were no absolute relationships seen between flame-resistance and the formation of stable ladder polymers, density, and oxygen content. ((orig.))
1994-07-27
Plasma flow measurement using directional Langmuir probe under weakly ion-magnetized conditions
Energy Technology Data Exchange (ETDEWEB)
It is both experimentally and theoretically demonstrated that ion flow velocity at an arbitrary angle with respect to the magnetic field can be measured with a directional Langmuir probe. Based on the symmetry argument, we show that the effect of magnetic field on directional probe current is exactly canceled in determining the ion flow velocity, and obtain the generalized relation between flow velocity and directional probe currents valid for any flowing direction. The absolute value of the flow velocity is determined by an in situ calibration method of the probe. The applicability limit of the present method to a strongly ion-magnetized plasma is experimentally examined. (author)
2000-07-01
International Nuclear Information System (INIS)
Chlorophyll a, chlorophyll b, and bacteriochlorophyll a in aqueous micellar solutions of Trition X 100 (2%) are readily oxidized by pulse-radiolytically generated N_3., Br_2"-., and (SCN)_2"-. radicals at nearly diffusion-controlled rates. The kinetic study suggests that pigment molecules occupy multiple sites in the micelle. Pheophytin a is only oxidized by N_3. and Br_2"-. radicals. The absolute spectra and the molar extinction coefficients of chlorophyll a, bacteriochlorophyll a, chlorophyll b, and pheophytin a cations have been determined. The chlorophyll a cation has been observed in the presence of pigment aggregates.
1981-11-01
Nuclear charge radii of light isotopes based on frequency comb measurements
Energy Technology Data Exchange (ETDEWEB)
Optical frequency comb technology has been used in this work for the first time to investigate the nuclear structure of light radioactive isotopes. Therefore, three laser systems were stabilized with different techniques to accurately known optical frequencies and used in two specialized experiments. Absolute transition frequency measurements of lithium and beryllium isotopes were performed with accuracy on the order of 10{sup -10}. Such a high accuracy is required for the light elements since the nuclear volume effect has only a 10{sup -9} contribution to the total transition frequency. For beryllium, the isotope shift was determined with an accuracy that is sufficient to extract information about the proton distribution inside the nucleus. A Doppler-free two-photon spectroscopy on the stable lithium isotopes {sup 6,7}Li was performed in order to determine the absolute frequency of the 2S {yields} 3S transition. The achieved relative accuracy ...
2010-02-11
Large-scale absolute dent evaluation campaign
International Nuclear Information System (INIS)
Steam generator tube denting is primarily caused by build-up of corrosion products at the tubesheet and the tube support plates. The mechanism of dent growth and the identification of tubes which should be removed from service have been studied. The practical outcome has been to prevent in-service tube leaks and to avoid unnecessary plugging of large numbers of tubes. A finite element study of tubesheet deformation (of pulled leaking tubes from reactors) was undertaken. Profilometry results for characterizing dents are given. Although several modifications have been made the high resolution profilometry system performance and the results obtained have proved satisfactory. (U.K.).
Large scale breeder reactor pump dynamic analyses
Energy Technology Data Exchange (ETDEWEB)
The lateral natural frequency and vibration response analyses of the Large Scale Breeder Reactor (LSBR) primary pump were performed as part of the total dynamic analysis effort to obtain the fabrication release. The special features of pump modeling are outlined in this paper. The analysis clearly demonstrates the method of increasing the system natural frequency by reducing the generalized mass without significantly changing the generalized stiffness of the structure. Also, a method of computing the maximum relative and absolute steady state responses and associated phase angles at given locations is provided. This type of information is very helpful in generating response versus frequency and phase angle versus frequency plots.
1982-01-01
Flatte-like distributions and the a{sub 0}(980)/f{sub 0}(980) mesons
Energy Technology Data Exchange (ETDEWEB)
We explore the features of Flatte-like parametrizations. In particular, we demonstrate that the large variation in the absolute values of the coupling constants to the {pi}{eta} (or {pi}{pi}) and K anti K channels for the a{sub 0}(980) and f{sub 0}(980) mesons that one can find in the literature can be explained by a specific scaling behaviour of the Flatte amplitude for energies near the K anti K threshold. We argue that the ratio of the coupling constants can be much better determined from a fit to experimental data. (orig.)
2005-03-01
This study presents a semi-active vibration control of a scaled two-span bridge structure. Magneto-rheological fluid dampers are utilized as the semi-active energy absorbing devices, and a bridge vibration control system is developed. Closed-loop control system based on fuzzy logic is used to suppress the bridge deck motion under random excitation. It is demonstrated that this fuzzy logic control system can significantly reduce the relative deck displacement using about 60% less power compared to passive on state, while the absolute deck acceleration remains practically unchanged.
2001-07-01
Energy Technology Data Exchange (ETDEWEB)
The bath of a manganese sulfate (BMS) is a system for absolute standardization of the neutron sources. This work establishes a functional relationship based on semi-empirical methods for the theoretical prediction of physical density values, concentration and rate between the hydrogen and manganese atoms presents in the solution of the BMS
2009-07-01
British Library Electronic Table of Contents (United Kingdom)
Determination of thermal to fast neutron flux ratio (ffast) and fast neutron flux (phi-fast) is required for fast neutron reactions, fast neutron activation analysis, and for correcting interference reactions. The ffast and subsequently phi-fast were determined using the absolute method. The ffast ranged from 48 to 155, and the phi-fast was found in the range 1.03x1010-4.89x1010 n cm-2 s-1. These values indicate an acceptable conformity and applicable for installation of the fast neutron facility at the MNA research reactor.
2011-01-01
International Nuclear Information System (INIS)
Attention is given to the folowing topics: population I and II variable stars; LP variables, the sun, and mass determination; and predegenerate and degenerate variables. Particular papers are presented on alternative evolutionary approaches to the absolute magnitude of the RR Lyrae variables; the evolution of the Cepheid stars; nonradial pulsations in rapidly rotating Delta Scuti stars; dynamical models of dust shells around Mira variables; and pulsations of central stars of planetary nebulae.
1990-05-28
COBE confounds the cosmologists
Energy Technology Data Exchange (ETDEWEB)
The validity of the Big Bang theory is evaluated. The basis of the Big Band theory and the supercluster observations of Tully, which conflict with the Big Band theory, are discussed. Various explanations for the existence of supercluster observations are proposed. The cosmic background explorer (COBE) is being utilized to detect energetic processes. The COBE contains a far IR absolute spectrometer, a differential microwave radiometer, and a diffuse IR background experiment. The hypothesis of the evolution of the universe of Hannes Alfven, which emphasizes the importance of electricity and magnetism, is presented and research illustrating the importance of electric currents and magnetic fields in space is examined.
1990-03-01
Absolute calibration of the antiproton detection efficiency for BESS below 1 GeV
Energy Technology Data Exchange (ETDEWEB)
An accelerator beam experiment was performed using a low-energy antiproton beam to measure antiproton detection efficiency of the BESS detector. Measured and calculated efficiencies derived from the BESS Monte Carlo simulation based on GRANT/GHEISHA showed good agreement. With detailed verification of the BESS simulation, the relative systematic error of detection efficiency derived from the BESS simulation has been determined to be {+-}5%, compared with the previous estimation of {+-}15% which was the dominant uncertainty for measurements of cosmic-ray antiproton flux. (author)
2001-12-01
A navigation filter for fusing DTM/correspondence updates
An algorithm for pose and motion estimation using corresponding features in images and a digital terrain map is proposed. Using a Digital Terrain (or Digital Elevation) Map (DTM/DEM) as a global reference enables recovering the absolute position and orientation of the camera. In order to do this, the DTM is used to formulate a constraint between corresponding features in two consecutive frames. The utilization of data is shown to improve the robustness and accuracy of the inertial navigation algorithm. Extended Kalman filter was used to combine results of inertial navigation algorithm and proposed vision-based navigation algorithm. The feasibility of this algorithms is established through numerical simulations.
2011-01-01
A measurement of the cross section for electron impact ionization of Ar"2"+, Kr"2"+ and Xe"2"+
International Nuclear Information System (INIS)
The crossed electron-ion beams technique was used to measure absolute cross sections for single ionization of Ar"2"+, Kr"2"+ and Xe"2"+ ions at electron energies ranging from threshold to 2000 eV. In contrast to some previous measurements, the metastable contents of the ion beams were small even in the case of Xe"2"+. All measured cross section curves show significant contributions from excitation-autoionization and possibly direct ionization of inner-shell electrons. There is evidence for resonance-excitation-double-autoionization in the case of Xe"2"+. (author).
The CFBP is counting on exemplariness, responsiveness and dialogue
Energy Technology Data Exchange (ETDEWEB)
Maintaining efforts at the end of a very average year in terms of tonnages marketed, maintaining a high degree of vigilance art responsiveness in the face of competition from other energy sources, emphasizing the exemplary safety of industrial plant, and playing an increased role as a source of proposals within the context of dialogue with the authorities in the current environment of stricter regulations. (author)
2003-03-01
Single Atom Detection With Optical Cavities
We present a thorough analysis of single atom detection using optical cavities. The large set of parameters that influence the signal-to-noise ratio for cavity detection is considered, with an emphasis on detunings, probe power, cavity finesse and photon detection schemes. Real device operating restrictions for single photon counting modules and standard photodiodes are included in our discussion, with heterodyne detection emerging as the clearly favourable technique, particularly for detuned detection at high power.
2008-01-01
The article explains the method of selecting the optimum energy for correcting the energy selectivity of tomographic projection and the optimum length of the crystals corresponding to it when the dual energy method in computerized tomography is used. Results of numerical calculations for actual materials and count results are presented.
1986-05-01
International Nuclear Information System (INIS)
Research and development activities are reported on absorption spectroscopy, calorimetry, electrolysis, emission spectroscopy, fluorimetry gas chromatography, infrared spectroscopy, liquid chromatography, liquid scintillation counting, mass spectroscopy, microscopy, radiometric analysis, and thermal analysis. A group of miscellaneous projects are also described.
International Nuclear Information System (INIS)
Full text: Many factors including drug efficacy, compliance and antibiotic resistance may influence HP eradication rates. The "1"4C urea breath test is a sensitive method of confirming HP colonisation and eradication. The aim was to study the relationships between the peak "1"4CO_2 counts on the breath test prior to treatment, smoking and HP eradication, and to assess if persistent or recurrent symptoms implied failure of eradication. 117 patients with DU and HP colonisation proved on biopsy or rapid urease test who underwent "1"4C urea breath tests at least one month after eradication treatment was ceased were studied (69 male, 48 female, mean age 41, range 26-87 y). Questionnaire assessment of treatment regimen, smoking history and dyspeptic symptoms was made at the time of the breath test. A sub-group of 43 patients who had pre- and post-treatment breath tests was studied to assess if high peak "1"4CO_2 counts on the pre-treatment breath ...
1997-12-01
Nuclear electromagnetic currents from chiral EFT
International Nuclear Information System (INIS)
Using the method of unitary transformation in combination with chiral effective field theory we derive the pion exchange contributions to the two-nucleon electromagnetic current. A formal definition of the current operator in this scheme and the power counting is presented. We discuss the implications of additional unitary transformations that have to be present to ensure the renormalizability of the one-pion exchange current. Further, we give explicit and compact results for the current in coordinate-space.
2010-03-15
Measurement of radon emanation rates using activated charcoal
Energy Technology Data Exchange (ETDEWEB)
The use of charcoal canisters in the measurement of radon emanation rates from surfaces is discussed. The counting efficiency of the canisters is dependent upon the volume of activated charcoal used, varying from approximately 0.7% for a full canister to 1.3% for a canister filled to only 1/3 of its capacity. The inclusion of Si-Gel desiccant reduces the radon collection efficiency of the canister.
1983-07-01
UK PubMed Central (United Kingdom)
A new portable apparatus—the Interval Distribution Recorder (IDR)—has been developed by WHO for assessing habitual physical activity. It measures R-R intervals and records counts in...Full Text Available
1974-01-01
Bragg-curve spectroscopy at high rates
Energy Technology Data Exchange (ETDEWEB)
The performance of a Bragg ionization chamber has been investigated as a function of the counting rate with approx.= 5 MeV/amu /sup 32/S beams: up to approx.= 20 kHz the energy resolution is below 0.9% and the Z resolving power is more than 50. (orig.).
1986-03-01
Assessment of internal contamination due to gamma emitters at nuclear power stations of Tarapur
International Nuclear Information System (INIS)
Personal monitoring and dose assessment of all radiation workers is an essential regulatory requirement as per radiation safety procedures of AERB and operating stations. The occupational workers of TAPS 1 and 2 and TAPS 3 and 4 are monitored for internal contamination due to high energy gamma emitters by whole body counting
2010-02-03
Anode wire ageing in proportional detectors at the BAC calorimeter of the ZEUS experiment
Energy Technology Data Exchange (ETDEWEB)
Experimental results of ageing effects in proportional counters are presented. The measurements were carried out for 158 ZEUS-BAC gas system monitoring counters. Deterioration of the pulse height distribution in azimuth and along the anode wire are presented. The influence of water admixture on counting gas is also described. (orig.).
1997-06-21
Analysis of #alpha#-emitters in the VLSI packaging materials
International Nuclear Information System (INIS)
The advance in the analysis of very small amount (<= 1#alpha#/cm"2h) of #alpha#-emitters in the cited materials is reviewed. The review, for which 75 references are listed, covers the period from January, 1978, to June, 1982. The use of #alpha#-ray counting, #alpha#-ray spectrometry, #gamma#-ray spectrometry, neutron activation analysis and mass spectrometry is discussed, and their relative merit and limitation are outlined. (J.P.N.).
Endothelial dysfunction is involved in radiation responses in many normal tissues, including intestine. Endothelium-directed interventions ameliorate intestinal radiation injury (radiation enteropathy) in animal models, and anecdotal reports also suggest a beneficial effect of heparin. This study assessed low molecular weight heparin as an intestinal radiation response modifier. Rats underwent localized small bowel irradiation. Groups of rats were treated with saline, nadroparin (3 mg/kg/d), or a non-anticoagulant heparin (SR80258, 3 mg/kg/d), from 3 days before to 2 weeks after irradiation. The intestinal radiation response was assessed 2 weeks and 6 weeks after irradiation using quantitative histology; morphometry, and cellular and molecular end-points. Compared to vehicle-treated controls, nadroparin significantly exacerbated structural radiation injury, neutrophil infiltration, and TGFbeta and collagen I immunoreactivity levels 2 weeks after irradiation. ...
2005-11-01
Twenty autopsy cases with 2009 pandemic influenza A (2009 H1N1) virus infection, performed between August 2009 and February 2010, were histopathologically analyzed. Hematoxylin-eosin staining, immunohistochemistry for type A influenza nucleoprotein antigen, and real-time reverse transcription-PCR assay for viral RNA were performed on formalin-fixed and paraffin-embedded specimens. In addition, the D222G amino acid substitution in influenza virus hemagglutinin, which binds to specific cell receptors, was analyzed in formalin-fixed and paraffin-embedded trachea and lung sections by direct sequencing of PCR-amplified products. There were several histopathological patterns in the lung according to the most remarkable findings in each case: acute diffuse alveolar damage (DAD) with a hyaline membrane (four cases), organized DAD (one case), acute massive intra-alveolar edema with variable degrees of hemorrhage (three cases), neutrophilic bronchopneumonia (five cases) and ...
2011-08-26
Glioblastoma multiforme is the most aggressive form of human brain tumor, which has no effective cure. Previously, we have demonstrated that overexpression of the C-terminal fragment of the human telomerase reverse transcriptase (hTERTC27) inhibits the growth and tumorigenicity of human cervical cancer HeLa cells. In this study, the therapeutic effect and molecular mechanisms of hTERTC27-mediated cancer gene therapy were further explored in vivo in established human glioblastoma xenografts in nude mice. We showed that intratumoral injection of adeno-associated virus carrying hTERTC27 (rAAV-hTERTC27) is highly effective in reducing the growth of the subcutaneously transplanted glioblastoma tumors. Histological analyses showed that rAAV-hTERTC27 treatment leads to profound necrosis, apoptosis, infiltration of polymorphonuclear neutrophils and reduced microvessel density in the tumor samples. To study the molecular mechanism of rAAV-hTERTC27-mediated antitumor ...
2007-03-23
Whole-body counting in the Marshall Islands
Energy Technology Data Exchange (ETDEWEB)
In 1978 the Marshall Islands Radiological Safety Program was organized to perform radiation measurements and assess radiation doses for the people of the Bikini, Enewetak, Rongelap and Utirik Atolls. One of the major field components of this program is whole- body counting (WBC). WBC is used to monitor the quantity of gamma- emitting radionuclides present in individuals. A primary objective of the program was to establish {sup 137}Cesium body contents among the Enewetak, Rongelap and Utirik populations. {sup 137}Cs was the only gamma-emitting fission radionuclide detected in the 1,967 persons monitored. {sup 137}Cs body burdens tended to increase with age for both sexes, and were higher in males. The average {sup 137}Cs dose Annual Effective Dose for the three populations was as follows: For Enewetak, the dose was 22{+-}4 {mu}Sv. For Utirik, the dose was 33{+-} 3 {mu}Sv. Since 1985 the Rongelap people have been self-exiled to Mejatto. Biological elimination should ...
1991-01-01
International Nuclear Information System (INIS)
We have performed X-ray magnetic diffraction (XMD) experiment of ferromagnets at the Photon Factory (PF) of the High Energy Accelerator Research Organization (KEK) in Tsukuba. In this study, we have upgraded the XMD experimental system in order to apply this method to as many samples as possible. Upgrade was made for (1) the X-ray counting system and related measurement program, (2) the electromagnet, and (3) the refrigerator. The performance of the system was enhanced so that (1) the counting rate capability was improved from 104cps to 105cps, (2) the maximum magnetic field was increased from 0.85T to 2.15T, and (3) the lowest sample temperature was reduced from 15K to 5K. The new system was applied to an orbital ordering compound of YTiO3, and we obtained spin magnetic form factor for the reflection plane (010) perpendicular to the b axis. The magnetic field of 2T was needed to saturate the magnetization of YTiO3 along the b axis. These are ...
2007-01-19
Strontium-90 and cesium-137 in service water from June to December, 1981
International Nuclear Information System (INIS)
Service water, 100 l each, was collected at an intake of a water treatment plant and at a tap after water was left running for five minutes. The carriers of strontium and cesium were added to water immediately after sampling, and the sample was vigorously stirred and filtered. Then it was passed through a cation exchange column at a rate of 80 ml/min. Strontium and cesium were eluted with hydrochloric acid from the cation exchange column, and separated. After the radiochemical separation, the mounted precipitates were counted for activity using low background beta counters normally for 60 min. Net sample counting rates were corrected for counter efficiency, recovery, self absorption and decay to obtain the content of strontium-90 and cesium-137 radioactivity per sample aliquot. From the results, concentrations of these nuclides in the original sample were calculated. The maximum values obtained were 0.29 pCi/l of Sr-90 in Kyoto in August, 1981, ...
1981-12-01
Ranking Scientific Publications Based on Their Citation Graph
CDS Invenio is the web-based integrated digital library system developed at CERN. It is a suite of applications which provides the framework and tools for building and managing an autonomous digital library server. Within this framework, the goal of this project is to implement new ranking methods based on the bibliographic citation graph extracted from the CDS Invenio database. As a first step, we implemented the Citation Count as a baseline ranking method. The major disadvantage of this method is that all citations are treated equally, disregarding their importance and their publication date. To overcome this drawback, we consider two different approaches: a link-based approach which extends the PageRank model to the bibliographic citation graph and a time-dependent approach which takes into account time in the citation counts. In addition, we also combined these two approaches in a hybrid model based on a time-dependent PageRank. In the ...
2009-01-01
Medicinal protection with Chinese herb-compound against radiation damage
Energy Technology Data Exchange (ETDEWEB)
Experiments were carried out on mice and the subjects irradiated for cancer therapy to evaluate the protective efficacy of a Chinese medicinal herb-compound (CMHC). The lethality and the degree of leucopenia caused by radiation in mice medicated with CMHC were significantly less in comparison with control mice (p less than 0.01 and p less than 0.001, respectively). CMHC significantly improved the WBC and the thrombocytes in irradiated workers (p less than 0.01 and p less than 0.001, respectively). The WBC count of 40 patients under radiotherapy while treated with CMHC recovered from 3450 +/- 77/c.mm to 5425 +/- 264/c.mm (p less than 0.001); whereas, in the control group, without any medication, the WBC count dropped significantly (p less than 0.001). Our results revealed the applicabilities of CMHC in protection against radiation damage in spaceflight and in other fields.
1990-08-01
British Library Electronic Table of Contents (United Kingdom)
This randomized, placebo-controlled, double blind, parallel dose-response study investigated the impact of 4-week commercial yoghurt consumption supplemented with Bifidobacterium animalis subsp. lactis (BB-12) and Lactobacillus acidophilus (LA-5) on fecal bacterial counts of healthy adults. Fifty-eight volunteers were randomly assigned to three different groups: 1. placebo (no probiotic, no starter and no green tea extract); 2. Yoptimal (10^9cfu/100g of BB-12 and LA-5 and 40mg of green tea extract) and 3. Yoptimal-10 (10^1^0cfu/100g of BB-12, 10^9cfu/100g of LA-5 and 40mg of green tea extract). These yoghurt products also contained Lactobacillus delbrueckii subsp. bulgaricus (10^7cfu/100g) and Streptococcus thermophilus (10^1^0cfu/100g). The quantitative PCR (qPCR) results showed that ther...
2011-01-01
Imaging properties of the Medipix2 system exploiting single and dual energy thresholds
Low noise, high resolution and high dose efficiency are the common requirements for most X-ray imaging applications. Especially in medical applications the dose efficiency is a necessity for detector systems. We present the imaging performance of the Medipix2 readout chip bump bonded to a 300 mu m thick Si detector as a function of the detection threshold, a free parameter not available in conventional integrating imaging systems. Spatial resolution has been measured using the modulation transfer function (MTF) and it varies between 8.2 Ip/mm and 11.0 Ip/mm at 70%. An associated measurement of noise power spectrum (NPS) permits us to derive the detective quantum efficiency (DQE) which can be as a high as 25.5 % for a broadband incoming spectrum. The influence of charge diffusion in the sensor together with threshold variation in the readout chip is discussed. Although the Medipix2 system is used in photon counting mode with a single threshold in energy, the system ...
2006-01-01
Hot Nights on Extrasolar Planets: Mid-IR Phase Variations of Hot Jupiters
We present results from Spitzer Space Telescope observations of the mid-infrared phase variations of three short-period extrasolar planetary systems: HD 209458, HD 179949 and 51 Peg. We gathered IRAC images in multiple wavebands at eight phases of each planet's orbit. We find the uncertainty in relative photometry from one epoch to the next to be significantly larger than the photon counting error at 3.6 micron and 4.5 micron. We are able to place 2-sigma upper limits of only 2% on the phase variations at these wavelengths. At 8 micron the epoch-to-epoch systematic uncertainty is comparable to the photon counting noise and we detect a phase function for HD 179949 which is in phase with the planet's orbit and with a relative peak-to-trough amplitude of 0.00141(33). Assuming that HD 179949b has a radius R_J < R_p < 1.2R_J and a small Bond albedo, it must recirculate less than 30% of incident stellar energy to its night side at the 1-sigma ...
2007-01-01
High order statistical signatures from source-driven measurements of subcritical fissile systems
Energy Technology Data Exchange (ETDEWEB)
This research focuses on the development and application of high order statistical analyses applied to measurements performed with subcritical fissile systems driven by an introduced neutron source. The signatures presented are derived from counting statistics of the introduced source and radiation detectors that observe the response of the fissile system. It is demonstrated that successively higher order counting statistics possess progressively higher sensitivity to reactivity. Consequently, these signatures are more sensitive to changes in the composition, fissile mass, and configuration of the fissile assembly. Furthermore, it is shown that these techniques are capable of distinguishing the response of the fissile system to the introduced source from its response to any internal or inherent sources. This ability combined with the enhanced sensitivity of higher order signatures indicates that these techniques will be of significant utility ...
1998-04-01
Focal plane detector for reactions with medium weight projectiles
Energy Technology Data Exchange (ETDEWEB)
A new focal plane detector for an Enge split pole spectrograph has been developed which is able to resolve individual elements and isotopes up to the mass 100 region. It consists of a 60 cm long position sensitive parallel plate avalanche counter backed by a large Bragg curve detector. Compared with other position sensitive focal plane counters the new detector system has a very good time resolution (less than 300 ps) and can be operated at much higher counting rates (up to 25 kHz). The intrinsic resolution of the position detector is less than 1 mm. In addition to the energy and the nuclear charge signal obtained from the Bragg curve detector the angle of incidence into the detector can be measured with an accuracy of better than 1/sup 0/. The detector has already been used in a variety of experiments where good timing, counting rate behavior, and excellent mass resolution over a large energy range were essential.
1988-12-01
Evaluation of fungal burden of medicinal plants submitted to gamma radiation process after 30 days
International Nuclear Information System (INIS)
Forty samples of medicinal plants (Peumus boldus, Camellia sinensis, Maytenus ilicifolia and Cassia angustifolia), purchased from pharmacies and street market in the five cities of Sao Paulo State, were irradiated using a "6"0Co gamma ray source (Gammacell) with a dose of 10.0 kGy, delivered at dose rate of 3.0 kGy/h. Nonirradiated samples were used as controls of fungal isolates. For fungal counts and identification in medicinal plants a serial dilutions from 10"-"1 to 10"-"6 of the samples were seeded in duplicates and plated using the method in Dichloran 18% Glycerol Agar (DG 18) and were counted after five days at 25 deg C. Mycological analysis of control samples revealed the presence of genera Aspergillus and Penicillium, which are known as toxigenic fungi. The process of gamma radiation was effective in reducing the number of colony forming units (cfu/g) in all irradiated samples of medicinal plants after 30 days, using the dose of 10.0 ...
Conceptual fusion power monitor based on the "1"6O(n,p)"1"6N reaction
International Nuclear Information System (INIS)
The feasibility of developing a fusion power monitor based on a fluid activation detector is considered here. The activation fluid may be either a liquid or a gas and its composition can be selected from a number of candidate materials to provide desired activation and decay characterisitcs. Performance calculations indicate that ordinary water would be a nearly ideal activation fluid. The "1"6O(n,p)"1"6N reaction has a threshold at about 10 MeV and a cross section energy dependence giving it a predominant response for unmoderated D-T fusion neutrons. Adequate activation can be obtained at moderate flow rates for remote counting away from the high radiation area of the reactor. The 7.16 sec half-life of "1"6N is ideal for remote counting with subsequent decay in a small hold-up tank to eliminate activity build-up in the recycled water.
1981-07-01
British Library Electronic Table of Contents (United Kingdom)
Summary In this study, antimicrobial activity of zein films incorporated with partially purified lysozyme and disodium ethylenediaminetetraacetic acid (Na2EDTA) has been tested on selected pathogenic bacteria and refrigerated ground beef patties. The developed films containing 700-g-cm-2 lysozyme and 300-g-cm-2 Na2EDTA showed antimicrobial activity on Listeria monocytogenes, Escherichia coli O157:H7, and Salmonella typhimurium. The application of lysozyme and Na2EDTA incorporated zein films on beef patties significantly decreased total viable counts (TVC) and total coliform counts after 5-days of storage compared to those of control patties (P-2EDTA or Na2EDTA alone significantly slowed down the oxidative changes in patties during storage (P-P-2EDTA for active packaging of refrigerated mea...
2011-01-01
In Graph Theory a number of results were devoted to studying the computational complexity of the number modulo 2 of a graph's edge set decompositions of various kinds, first of all including its Hamiltonian decompositions, as well as the number modulo 2 of, say, Hamiltonian cycles/paths etc. While the problems of finding a Hamiltonian decomposition and Hamiltonian cycle are NP-complete, counting these objects modulo 2 in polynomial time is yet possible for certain types of regular undirected graphs. Some of the most known examples are the theorems about the existence of an even number of Hamiltonian decompositions in a 4-regular graph and an even number of such decompositions where two given edges e and g belong to different cycles (Thomason, 1978), as well as an even number of Hamiltonian cycles passing through any given edge in a regular odd-degreed graph (Smith's theorem). The present article introduces a new algebraic technique which generalizes the notion of ...
2010-01-01
Retrospective Monte Carlo dose calculations with limited beam weight information
International Nuclear Information System (INIS)
An important unresolved issue in outcomes analysis for lung complications is the effect of poor or completely lacking heterogeneity corrections in previously archived treatment plans. To estimate this effect, we developed a novel method based on Monte Carlo (MC) dose calculations which can be applied retrospectively to RTOG/AAPM-style archived treatment plans (ATP). We applied this method to 218 archived nonsmall cell lung cancer lung treatment plans that were originally calculated either without heterogeneity corrections or with primitive corrections. To retrospectively specify beam weights and wedges, beams were broken into Monte Carlo-generated beamlets, simulated using the VMC++ code, and mathematical optimization was used to match the archived water-based dose distributions. The derived beam weights (and any wedge effects) were then applied to Monte Carlo beamlets regenerated based on the patient computed tomography densities. Validation of the process was performed against five ...
2007-01-01
Multi-Phase Fracture-Matrix Interactions Under Stress Changes
Energy Technology Data Exchange (ETDEWEB)
The main objectives of this project are to quantify the changes in fracture porosity and multi-phase transport properties as a function of confining stress. These changes will be integrated into conceptual and numerical models that will improve our ability to predict and optimize fluid transport in fractured system. This report details our progress on: (a) developing the direct experimental measurements of fracture aperture and topology and fluid occupancy using high-resolution x-ray micro-tomography, (b) counter-current fluid transport between the matrix and the fracture, (c) studying the effect of confining stress on the distribution of fracture aperture and two-phase flow, and (d) characterization of shear fractures and their impact on multi-phase flow. The three-dimensional surface that describes the large-scale structure of the fracture in the porous medium can be determined using x-ray micro-tomography with significant accuracy. Several fractures have been scanned and the ...
2005-12-07
DEFF Research Database (Denmark)
Methods for estimating particle number may be based on at least three different principles. Two of them, isolation of particles and indirect counting, have been predominant until recently. The new methods based on section pairs (disectors) are unbiased and far more efficient. The three principles and their historical developments are described, emphasizing that the newly developed principles have old roots, which were forgotten until recently. It is concluded, that 'learned societies' combined with individual enthusiasm are material for the spread and development of new ideas.
1989-01-01
Shielded and unshielded geometries in the search for orphan sources
Energy Technology Data Exchange (ETDEWEB)
A car-borne NaI(Tl) spectrometric system was used together with a {sup 137}Cs source to obtain realistic data in the search for unshielded and semi-shielded orphan sources. The potassium-stripped counts (PSC) method was used to estimate the influence by the shielding on the detection ability. A reduction of about 5% in the critical distance was obtained for the semi-shielded source. A curve fitting method was also developed and evaluated. Results from the curve fitting method showed inferior ability to find the source compared to the PSC method. However, it can be a useful complementary tool, for characterisation of the source shielding, and estimation of the distance from the road.
2006-05-15
Shielded and unshielded geometries in the search for orphan sources
International Nuclear Information System (INIS)
A car-borne NaI(Tl) spectrometric system was used together with a "1"3"7Cs source to obtain realistic data in the search for unshielded and semi-shielded orphan sources. The potassium-stripped counts (PSC) method was used to estimate the influence by the shielding on the detection ability. A reduction of about 5% in the critical distance was obtained for the semi-shielded source. A curve fitting method was also developed and evaluated. Results from the curve fitting method showed inferior ability to find the source compared to the PSC method. However, it can be a useful complementary tool, for characterisation of the source shielding, and estimation of the distance from the road.
2006-05-01
International Nuclear Information System (INIS)
The improved facilities of the ISOLDE isotopic separator on-line with the 600 MeV synchrocyclotron at CERN opened the possibility to reach nuclei very far from stability (as far as 22 neutrons deficient in the Cs region and 27 neutrons deficient in the Hg region). Simultaneously the development of on-line spectrometry allowed the study of nuclei with very short half-lives and low counting rates. Results recently obtained in the odd-A iridium region are presented after a short summary of recent on-line devices developments and results. (Auth.).
Radon measurements in dwellings using activated charcoal
Energy Technology Data Exchange (ETDEWEB)
In Sweden there is a demand for a method of measuring radon in dwellings with high accuracy and at a low cost. A method of determining radon concentration (Bq.m/sup -3/) in dwellings has been developed at the Swedish National Testing Institute. A plastic canister containing activated charcoal has been tested in a radon chamber (volume 20 m/sup 3/) to determine the effects of relative humidity, temperature and exposure time. The activated charcoal in the canister adsorbs radon from the air surrounding the canister. The radon concentration is determined by counting the gamma rays from the decay of radon and daughters. The theory and preliminary results from calibrations and field measurements are reported.
1984-01-01
Radon in the office environment
Energy Technology Data Exchange (ETDEWEB)
The results of weekly radon concentration measurements in an office environment using a novel envelope-type radon monitor for short-term exposure periods are presented. The commercially available LR-115 damage track detectors are used and the chemically etched sheets are spark counted. The measurements were made over a period of one year. The indoor radon concentration varies from {approx} 20 Bq.m{sup -3} to {approx} 300 Bq.m{sup -3} with the average of 130, 81 and 73 Bq.m{sup -3} for three different rooms resulting in the annual dose of 4.5, 2.8 and 2.5 mSv, respectively. (author)
1992-07-01
Radioprotective activity in some medicinal herbs
Energy Technology Data Exchange (ETDEWEB)
Water-soluble, ethanol-insoluble extracts prepared from several medicinal herbs of the Araliaceae and other families were tested for their radioprotective activity by either measuring 30 days survival rates (a commonly applied method) or counting the thrombocytes 14 days after irradiation (an improved method) in mice. The extracts were i.p. injected once within 4 min after the whole body X-ray irradiation. Of 12 materials examined, Aralia elata, Angelica acutiloba and Morus bombysis seemed to be good starting materials for preparing radioprotective substance(s) because of their relatively high specific activity and high yields of the extracts. (author).
1993-09-01
Radioactivity of people in Finland after the Chernobyl accident in 1986
International Nuclear Information System (INIS)
After the reactor accident at Chernobyl on April 26, 1986 radioactive fallout was carried by air currents to most parts of Europe. The radioactive air currents reached Finland on April 27. Immediately after the arrival of such air in Finland, contamination of people by radioactive nuclides began via inhalation of this air. The ingestion route become important later, when radionuclides were transported via different foodchains to man. To determine the level of radionuclides in the body and to estimate the internal radiation doses caused by the Chernobyl accident, whole-body counting measurements were performed. The results of whole-body counting of six different groups of Finnish people measured during 1986 after the accident at Chernobyl are reported. Three were reference groups measured routinely once or twice annually, two groups were comprised of workers at nuclear power stations and one group consisted of 262 persons not belonging to any ...
2004-02-01
Nondestructive analysis for "2"3"2U and decay progeny in animal tissues
International Nuclear Information System (INIS)
Direct determination of "2"3"2U and its decay products in animal tissues appears to be feasible using an intrinsic Ge(Li) diode detector (for energies of 5-100 keV) and a NaI(Tl) anticoincidence-shielded Ge(Li) diode for higher-energy gamma photons. The detection sensitivity for "2"3"2U and "2"2"8Th is 0.03 and 0.01 nCi, respectively, using a 300-min counting time.
1977-05-01
Neutron monitoring on cold fusion experiments
International Nuclear Information System (INIS)
A helium-3 proportional detector was equipped with the experiment of Liaw-type electrolytic cell contained eutectic LiCl-KCl molten salt saturated by LiD electrolytic to collect the informations of the rate and the energy distribution of possible neutron produced during the electrolysis processes. For long time monitoring, the significant reproducible neutron bursts appeared at several runs of cells during electrolytic processing. The neutron counting rate increased about a factor of two above the level of the background measurement. The pulse height signals were verified of neutron energy ranging from thermal up to 350 keV. (author).
1992-10-01
Multi-megajoule Nd: glass fusion laser design
Energy Technology Data Exchange (ETDEWEB)
New technologies make multi-megajoule glass lasers economically feasible. Laser architectures using harmonic switchout, target plane holographic injection, phase conjugation, continuous apodization and higher amplifier efficiencies have been devised. A plan for a multi-megajoule laser which can be built for an acceptable cost relies on manufacturing economies of scale and the demonstration of the new technologies presented here. These include continuous pour glass production, rapid harmonic crystal growth, switching of large blocks of power using larger capcaitors packed more economically and by using large identical parts counts.
1986-04-04
Moment based estimation of stochastic Kronecker graph parameters
Stochastic Kronecker graphs supply a parsimonious model for large sparse real world graphs. They can specify the distribution of a large random graph using only three or four parameters. Those parameters have however proved difficult to choose in specific applications. This article looks at method of moments estimators that are computationally much simpler than maximum likelihood. The estimators are fast and in our examples, they typically yield Kronecker parameters with expected feature counts closer to a given graph than we get from KronFit. The improvement was especially prominent for the number of triangles in the graph.
2011-01-01
Laboratory robotics projects in the Analytical Development Division at the Savannah River Laboratory
International Nuclear Information System (INIS)
To encourage the application of robotics technology for routine radiobench applications, a laboratory dedicated to the research and development of contained robotic systems is being constructed. The facility will have several robots located in laminar flow hoods, and the hoods are being designed to allow the possibility for multiple robots to work together. This paper presents both the design features of the hoods and the general layout of the laboratory, and also discusses an application of a robotic system for the routine nuclear counting of gamma tube samples. The gamma tube system is presently operating in one of the routine analysis laboratories. 5 figs.
Improved quadrant anode image sensor with microchannel plates
Energy Technology Data Exchange (ETDEWEB)
We describe a position-sensitive event-counting microchannel plate detector with a quadrant anode readout system that combines the advantages of several centroid-finding readout techniques. The relative amount of charge collected by each quadrant of the anode mounted behind the output side of the microchannel plate is used to localize each event. The position-sensitive area is about 80% of the active microchannel plate surface. By changing a single voltage a remote-controlled image magnification can be achieved. Due to a correction function that minimizes image distortions the imaging characteristics of this low-cost readout system are similar to those of expensive resistive anodes.
1987-11-15
Gastrointestinal absorption of lead-203 chloride in man
International Nuclear Information System (INIS)
Studies of the gastrointestinal absorption of lead-203 chloride were carried out on 11 normal subjects, 7 males and 4 females. Whole body counting of these subjects after administration of 74 kBq (2 #mu#Ci) of cyclotron-produced lead-203 chloride showed a mean absorption of 21.3% of the dose with a range from 10.4 to 47.7%. The male subjects had a lower mean absorption of 18.1% of the dose compared with a mean of 26.9% in the females. Although this difference did not reach statistical significance, it is postulated that male/female differences in absorption may relate to differences in iron saturation of the subjects.
Fuzzy performance measurement of a supply chain in manufacturing companies
British Library Electronic Table of Contents (United Kingdom)
This paper is aimed to present a fuzzy decision making approach to deal with the performance measurement in supply chain systems. In the manufacturing environment, performance measurement is based on different quantitative and qualitative factors. Some of these factors may have a larger effect on the performance measure than others. Units of measure of the quantitative factors are different such as time, money, percentage, ratio, and counts. Thus, this paper presents a performance measurement approach based on fuzzy set theory and the pair-wise comparison of Analytical Hierarchy Process (AHP), which ensures the consistency of the designer's assignments of importance of one factor over another to find the weight of each of the manufacturing activity in the departmental organization. In the ...
2011-01-01
Effects of "2"3"9Pu administered at 9 days of gestation on hematologic development of the rat
International Nuclear Information System (INIS)
Injection of pregnant rats with monomeric "2"3"9Pu after 9 days of gestation decreased their leukocyte and reticulocyte counts at 5 and 10 days postexposure. Most of the fetal hematologic enumerative values were unaffected by injection of monomeric "2"3"9Pu. There was, however, a major change in the maturation of the cells of the erythroid series, as indicated by a difference in the distribution between cell types. The weight of the yolk sac and fetal liver, and the cellularity of the fetal spleen were decreased.
1977-05-01
Development of the SRS environmental counting laboratory gamma spectroscopy system
International Nuclear Information System (INIS)
The Savannah River Site (SRS), one of several U.S. Department of Energy (DOE) facilities, produces nuclear materials for national defense and for other government and civilian uses. SRS ceased production of defense materials in 1988, and the site's main activities now involve waste management and environmental restoration. These programs have generated extensive effluent monitoring and environmental surveillance programs for the Environmental Monitoring Section (EMS), which performs #approx#105,000 radiological analyses on 30,000 samples a year. Gamma spectroscopy is performed on an estimated 10,000 samples annually. This report describes a program to develop and improve the EMS system.
1996-06-16
Characterization of nuclear fuels by ICP mass-spectrometric techniques
British Library Electronic Table of Contents (United Kingdom)
Isotopic analyses of radioactive materials such as irradiated nuclear fuel are of major importance for the optimization of the nuclear fuel cycle and for safeguard aspects. Among the mass-spectrometric techniques available, inductively coupled plasma mass spectrometry (ICP-MS) and thermal ionization mass spectrometry are the most frequently applied methods for nuclear applications. Because of the low detection limits, the ability to analyze the isotopic composition of the elements and the applicability of the techniques for measuring stable as well as radioactive nuclides with similar sensitivity, both mass-spectrometric techniques are an excellent amendment to classical radioactivity counting methods. The paper describes selected applications of multicollector ICP-MS in combination with c...
2008-01-01
Energy Technology Data Exchange (ETDEWEB)
The use of the method is described on powder samples before and after sintering with a La content of up to 1%. For excitation of the K series of La a /sup 241/Am source with an activity of 1.11 GBq was used. The obtained results showed that the method is sufficiently accurate (error 7%) at a short period of measurement (100 s). It gives satisfactory results even in the comparison of the experimental relative count rate and the theoretically calculated value despite the fact that the analytical signal comes from the sample surface.
1983-05-01
International Nuclear Information System (INIS)
The use of the method is described on powder samples before and after sintering with an La content of up to 1%. For excitation of the K series of La a _2_4_1Am source with an activity of 1.11 GBq was used. The obtained results showed that the method is sufficiently accurate (error 7%) at a short period of measurement (100 s). It gives satisfactory results even in the comparison of the experimental relative count rate and the theoretically calculated value despite the fact that the analytical signal comes from the sample surface. (Ha).
1983-01-01
Application of proportional counters in Polish medicine and agriculture
Energy Technology Data Exchange (ETDEWEB)
In the laboratory of Elementary Particle Physics and Detectors at the Faculty of Physics and Nuclear Techniques of the University of Mining and Metallurgy, research works on the development of proportional counters for the detection of X- and soft {gamma}-rays and {alpha}, {beta} particles have been carried out As a result of optimization of counters characteristic parameters such as: energy resolution, life time, count rate effect and temperature effect the operating stability has been reached and the elaborated detectors have been applied not only in research laboratories, but also in Polish industry, medicine and agriculture. Examples of above mentioned applications have been presented in the paper. (author). 7 refs, 7 figs, 1 tab.
1996-12-31
An improved quadrant anode image sensor with microchannel plates
International Nuclear Information System (INIS)
We describe a position-sensitive event-counting microchannel plate detector with a quadrant anode readout system that combines the advantages of several centroid-finding readout techniques. The relative amount of charge collected by each quadrant of the anode mounted behind the output side of the microchannel plate is used to localize each event. The position-sensitive area is about 80% of the active microchannel plate surface. By changing a single voltage a remote-controlled image magnification can be achieved. Due to a correction function that minimizes image distortions the imaging characteristics of this low-cost readout system are similar to those of expensive resistive anodes. (orig.).
1987-11-01
An improved quadrant anode image sensor with microchannel plates
We describe a position-sensitive event-counting microchannel plate detector with a quadrant anode readout system that combines the advantages of several centroid-finding readout techniques. The relative amount of charge collected by each quadrant of the anode mounted behind the output side of the microchannel plate is used to localize each event. The position-sensitive area is about 80% of the active microchannel plate surface. By changing a single voltage a remote-controlled image magnification can be achieved. Due to a correction function that minimizes image distortions the imaging characteristics of this low-cost readout system are similar to those of expensive resistive anodes.
1987-11-01
Advances in imaging THGEM-based detectors
International Nuclear Information System (INIS)
We report on recent measurements with Thick GEM-like (THGEM)-based imaging detectors. The THGEM is a robust gaseous electron multiplier similar to GEM but with larger dimensions. It has high electron multiplication, of 105 and 107 in single- and double-THGEM structure, respectively, fast signals and ?10MHz/mm2 counting rate capability. It can be produced in any shape and over large area. In view of many possible applications of THGEM-based imaging detectors, in particle physics and beyond, we have recently studied the localization properties of a 2D 10x10cm2 detector. The results of these studies are presented.
2007-03-01
ent-Rosane and abietane diterpenoids as cancer chemopreventive agents
British Library Electronic Table of Contents (United Kingdom)
Two ent-rosane- (cuzcol, 1 and 6-dehydroxycuzcol, 2) and a abietatriene- (salvadoriol, 3) type diterpenoids have been isolated from Maytenus cuzcoina and Crossopetalum uragoga, respectively, along with five known diterpene compounds (4-8). Their stereostructures have been elucidated on the basis of spectroscopic analysis, including 1D and 2D NMR techniques, and computational data. The absolute configuration of cuzcol was determined by application of Riguera ester procedure. This is the first instance of isolation of ent-rosane diterpenoids from species of the Celastraceae. The isolated diterpenes were found to be potent anti-tumour-promoter agents, and carnosol (7) also showed a remarkable chemopreventive effect in an in vivo two-stage carcinogenesis model.
2011-01-01
[Dysspermia due to inflammation. The evaluation of sperm cultures].
The study evaluates 160 cases of positive spermioculture taken from 522 sterile individuals examined by the authors at the Couple Sterility Outpatient unit in Department A of the Institute of Gynecology and Obstetrics at Turin University during the period between January 1984 and December 1993. The germs responsible for infection were assayed in order to evaluate the strains which showed the highest incidence every year. Whereas there was no significant change in the absolute number of cases of sterility over the period, the number of cases caused by infection increased significantly during the second five-year period. It was found that the germs predominantly implicated in the genesis of male sterility formed part of the so-called mixed flora group, responsible in women for syndromes of often asymptomatic bacterial vaginosis which are not identified and consequently not treated. PMID:8559444
This paper presents a semi-active vibration control of a scaled two-span bridge structure. Magneto-rheological fluid dampers are utilized as the semi-active energy absorbing deices and a bridge vibration control system is developed. Closed-loop control system based on fuzzy logic is used to suppress the bridge deck motion under random excitations. The sufficient condition for the closed-loop stability of the fuzzy control system is derived from the variable structure system theory. It is demonstrated that this stable fuzzy control system can significantly reduce the relative deck displacement using about 55 percent less power compared to passive-on state, while the absolute deck acceleration is relatively unaffected.
2002-06-01
Recycling flow control device for a nuclear reactor
International Nuclear Information System (INIS)
Object: To permit a valve operation test to be periodically made during plant operation without causing variations in plant power by detecting flow control valve defect on the basis of a valve aperture alteration instruction. Structure: Step signals which are equal in absolute value and opposite in sign are coupled to the input side of flow controllers provided on the recycling loops of two or more recycling flow control systems. With these inputs the aperture of the flow control valve on one side is increased (or reduced) while the aperture of the valve on the other side is reduced (or increased). As a result, the recycling flow rate in the loop on one side is increased (or reduced) while that on the other side is reduced (or increased). Whether the valve is normally operating or not is confirmed by checking the recycling flow rate and valve aperture. (Nakamura, S.).
Energy Technology Data Exchange (ETDEWEB)
Cellular telephones emit a radiofrequency electromagnetic field, part of which is absorbed in the user's head. Many studies have been conducted to look for their possible health hazard to human, at the experimental, epidemiological or clinical level. After a short recall on dosimetry, the author describes the state-of-the art about harmful and irreversible effects, up to now not confirmed, and about some benign symptoms which look absolutely actual. A causal relationship of the electromagnetic field on these benign symptoms is however not proven; other, studies are running to evaluate their possible long-term consequences. Interferences with cardiac pacemakers can easily be avoided by holding the telephone handset farther than 10 cm. (author)
1999-12-01
Probing the origin of inertia behind spacetime deformation
To investigate the origin and nature of inertia, we introduce a new concept of hypothetical 2D, so-called, "master-space" (MS), subject to certain rules. The MS, embedded in the background 4D-spacetime, is an indispensable individual companion to the particle of interest, without relation to every other particle. We argue that a deformation/(distortion of local internal properties) of MS is the origin of inertia. With this perspective in sight, we construct the alternative relativistic theory of inertia (RTI), which allows to compute the relativistic inertial force acting on an arbitrary point-like observer due to its "absolute acceleration". We go beyond the hypothesis of locality with an emphasis on distortion of MS, which allows to improve essentially the standard metric and other relevant geometrical structures related to the noninertial reference frame of an arbitrary accelerated observer. We compute the inertial force exerted on the photon in a gravitating ...
2011-01-01
Photo-emission-electron-microscopy for characterization of an operating organic electronic device
Energy Technology Data Exchange (ETDEWEB)
Photoemission-electron-microscopy (PEEM) is introduced as a tool for the characterization of organic electronic devices. PEEM-measurements are used for imaging as well as for spectroscopic analyses by illumination with light of a Hg-lamp (4.9 eV), a D2 lamp (7.3 eV), and with synchrotron radiation for resonant photoelectron spectroscopy. We determine the charge carrier concentration inside the channel region of the organic device and its lateral distribution. From resonant photoelectron spectroscopy (RPES) we deduce the electronic states which are accessible with the Hg and D2 illumination. Photoelectron-spectroscopy at selected areas ({mu}-PES) gives information on the absolute values of surface potentials in lateral resolution. We are able to perform these studies with applied voltages at the source- and drain-electrode.
2006-01-20
Optimization techniques for parameter estimations: case studies in CO{sub 2} separation processes
Energy Technology Data Exchange (ETDEWEB)
Application of an optimization technique to extract the non-ideal parameters of gas absorption with chemical reactions process was described. The gas absorption was modeled using mass transfer theory to represent the realistic behaviors of an absorber. The model was a highly non-linear iterative model which correlated the overall rate of absorption as the function of unknown non-ideal parameters, including the physical liquid mass transfer coefficient and the wetted interfacial area of of packings. The optimization program was developed to minimize the sum of squares of relative errors between the model predictions and the experimental data. Four sets of experimental data (case studies) with different operating conditions were used for extracting parameters. Comparisons between predicted and experimental measured overall absorption rate were in good agreement, average absolute value of relative errors not exceeding 5.4 %. 18 refs., 3 tabs., 4 figs.
1995-12-31
British Library Electronic Table of Contents (United Kingdom)
Abstract Four stratigraphic sections in the southern part of the Columbia Basin preserve a sequence of aeolian and non-aeolian sediments ranging in age from 943 to >470 14C ka based on accelerator mass spectrometry radiocarbon dating of fossil molluscs, geochemistry of Cascade Mountain-sourced tephra and association with formally recognized pedostratigraphic units (the Washtucna and Old Maid Coulee soils). Study sections are interpreted as representing concurrent deposition of loess and distal Missoula Flood rhythmites in valleys tributary to main drainages backflooded during the Missoula Floods, and formation of carbonate and iron-rich soils. Sediments belong to the formally recognized L-1 and L-2 loess units established for the Palouse loess, which were deposited in the Columbia Basin su...
2010-01-01
Netrawalm: Network Based Resource Aware Application Layer Multicast for Multiparty Video Conference
IP Multicast is one of the most absolute method for large bandwidth Internet applications such as video conference, IPTV, E-Learning and Telemedicine etc., But due to security and management reason IP Multicast is not enabled in Internet backbone routers. To achieve these challenges, lot of Application Layer Multicast (ALM) has been proposed. All the existing protocols such as NICE, ZIGZAG and OMNI are trying to reduce average delay by forming a Multicast tree. But still that problem has not been addressed fully. We are proposing a new protocol called NetRawALM, which will address the average delay, Reliability between nodes, Scalability of conference, Heterogeneity and resilient data distribution for real time multimedia applications by constructing the Network based Resource aware Multicast tree algorithm. This is very dynamic and decentralised. The proposed architecture is a LAN aware; it is used to reduce Internet Traffic.
2011-01-01
Monitoring transplanting operation of rice crop using passive microwave radiometer data
British Library Electronic Table of Contents (United Kingdom)
This study highlights a methodology to detect the transplanting operation of wetland rice at a regional scale using SSM/I brightness temperature in frequencies like 19, 37 and 85 GHz with vertical polarization. A cloud removal algorithm was used to make weekly composites of the brightness temperature, which were used to estimate the soil wetness index (SWI). Flooding of rice fields with water for transplanting induces very high change in SWI due to contrasting dielectric constant of water (80) and soil (4). Different weather conditions and fractional wet area under the footprint of sensor affect SWI, hence absolute value of SWI was not adequate. Therefore, multi-year SWI anomaly was used to generate a threshold value of SWI change to detect when SWI change between two consecutive weeks was...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
SUMMARY Spontaneous potentials associated with volcanic activity are often interpreted by means of the electrokinetic potential, which is usually positive in the flow direction (i.e. Zeta potential of the rock is negative). The water-rock interactions in hydrothermal zones alter the primary minerals leading to the formation of secondary minerals. This work addresses the study of calcite precipitation in a sand composed of 98 per cent quartz and 2 per cent calcite using streaming potential measurements. The precipitation of calcite as a secondary mineral phase, inferred by high calcite saturation indices and by a fall in permeability, has a significant effect on the electrokinetic behaviour, leading to a significant reduction in the Zeta potential (in absolute value) and even a change in si...
2006-01-01
Information flow, causality, and the classical theory of tachyons
International Nuclear Information System (INIS)
Causal paradoxes arising in the tachyon theory have been systematically solved by using the reinterpretation principle as a consequence of which cause and effect no longer retain an absolute meaning. However, even in the tachyon theory, a cause is always seen to chronologically precede its effect, but this is obtained at the price of allowing cause and effect to be interchanged when required. A recent result has shown that this interchange-ability of cause and effect must not be unlimited if heavy paradoxes are to be avoided. This partial recovery of the classical concept of causality has been expressed by the conjecture that transcendent tachyons cannot be absorbed by a tachyon detector. In this paper the directional properties of the flow of information between two observers in relative motion and its consequences on the logical self-consistency of the theory of superluminal particles are analyzed. It is shown that the above conjecture does not provide a ...
International Nuclear Information System (INIS)
Cavity ringdown spectroscopy (CRDS) with continuous-wave (cw) laser excitation has added high frequency resolution to the ability of CRDS being used for the absolute quantification of trace-level species present in many chemical processes. Cavity dithering technique has easily resolved the problem of resonant coupling of a cw laser light into a high-finesse cavity. The present study addresses the potential uncertainty involved in such cw-CRDS techniques incorporating the cavity mirror motion, i.e., the doppler frequency shift of a probe light inside the cavity. In the high-resolution spectroscopic work of megahertz-accuracy, even the influence of intracavity doppler effect may become significant.
2001-11-01
High-throughput proteomics of breast carcinoma cells: a focus on FTICR-MS
Energy Technology Data Exchange (ETDEWEB)
Discovery of better biomarkers for diagnosis, prognosis, and therapy-response prediction is the most critical task of a scientific quest aimed at developing newly designed, tailor-made therapies for patients with cancer. Consequently, a proteome wide analysis, in addition to genomic studies, is an absolute requirement for a complete functional understanding of tumor biology. Ultra-sensitive, high-performance Fourier transform ion cyclotron resonance (FTICR) mass spectrometry (MS) currently holds an important role in fulfilling the demands of biomarker discovery. In this review, we describe the applicability of FTICR MS for breast cancer proteomics, particularly for the analysis of complex protein mixtures obtained from a limited number of cells typically available from clinical specimens.
2008-06-05
Geometry effects in the pulsed magnetization of high-temperature superconductor bulk parts
International Nuclear Information System (INIS)
The dynamic response of cylindrical and ring-shaped YBaCuO bulk parts to pulsed magnetic fields is calculated by using small sets of finite elements. Some comparisons with experimental results are provided, and they give confidence in the modelling of the superconducting properties. Transient magnetizations as a function of time and space as well as shapes and absolute values of trapped magnetic flux profiles are presented. The influence of the sample geometry is investigated for different millisecond pulsed magnetization processes. Results are reported for different radial thicknesses and heights, different pulse durations, peak magnetic fields and pulse sequences with and without stepwise cooling. Comparisons concerning the achievable trapped magnetic field and flux are made, and implications for the use of high-temperature superconductor bulk parts as cryo-permanent magnets in potential applications like electric machinery are discussed.
2005-02-01
Feasibility analysis for attosecond X-ray pulses at FERMI@ELETTRA free electron laser
Energy Technology Data Exchange (ETDEWEB)
We present preliminary analysis for the feasibility of the attosecond x-ray pulses at a proposed FERMI@ELETTRA free electron laser (FEL) [1]. In part 1 we restrict ourselves to minimal modifications to the proposed FEL and consider a scheme for attosecond x-ray production which can be qualified as a small add-on to a primary facility. We demonstrate that at 5-nm wavelength our scheme is capable for production of pulses with an approximate duration of 100 attoseconds at approximately 2 MW peak power and with an absolute temporal synchronization to a pump laser pulse. In part 2 we propose to use an FEL amplifier seeded by a VUV signal and to follow it by the scheme for attosecond x-ray production described in part 1.
2004-09-01
Fast neutron nuclear data: Pu-239 revision and Am status
International Nuclear Information System (INIS)
Neutron cross sections for Pu-239 and Am-241, -242m, -243 have been analyzed with the aid of theoretical models. A deformed optical potential that fits total, elastic and inelastic differential cross section data and neutron strength functions for Pu-239 and Am-241 have been used. In case of Pu-239 the consistency of absolute fission data and (n, 2n) cross section is investigated. Because of the strong discrepancies in Am fission cross section data a consistent set of calculated cross section values for the chain of Am nuclei is proposed. The present state of knowledge concerning first chance fission cross section allows to analyze fission cross section data of Am-241, -242m, -243, up to 20 MeV. The results thus obtained are compared with ENDF/B-V and JENDL-3 libraries. (orig.).
International Nuclear Information System (INIS)
The excitation functions of the reactions "9"8Mo(d,p)"9"9Mo and "1"0"0Mo(d,p)"1"0"1Mo have been determined by irradiation of stacked foils with deuterons of energies less than 13 MeV and non-destructive determination of the absolute activity of the Mo radioisotopes by semiconductor #gamma#-ray spectrometry. From the excitation functions, the thick-target yields and the saturation production rates of "9"9Mo and "1"0"1Mo for deuteron energies of 13.0 MeV and 11.7 MeV have been calculated. Implications for the production of "9"9Mo for generators of sup(99m)Tc are discussed. (author).
International Nuclear Information System (INIS)
Measurements of absolute total cross sections for electron-impact excitation of Ar"7"+(3s#->#3p) using a merged-beams electron-energy-loss technique show that near threshold the inelastically scattered electrons are ejected primarily in the backward direction. This unusual angular scattering has not been previously observed for atoms or ions, but may be typical for multiply charged ions. The total cross sections, measured over an energy range to 2.2 eV above threshold, agree with seven-state R-matrix close-coupling calculations. Both close-coupling and distorted-wave calculations also confirm the backscattering observed in these measurements.
British Library Electronic Table of Contents (United Kingdom)
Passive microwave soil moisture datasets can be used as an input to provide an integrated assessment of climate variability as it relates to agricultural production. The objective of this research was to examine three passive microwave derived soil moisture datasets over multiple growing seasons in contrasting Canadian agricultural environments. Absolute and relative soil moisture was evaluated from two globally available datasets from the Advanced Microwave Scanning Radiometer for EOS (AMSR-E) sensor using different retrieval algorithms, as well as relative soil wetness at a weekly scale from the Special Sensor Microwave/Imager (SSM/I) sensor. At a daily scale, the Land Parameter Retrieval Model (LPRM) provides a better estimate of surface soil moisture conditions than the National Snow a...
2010-01-01
Evaluation method for corrosion resistance of zirconium alloy
International Nuclear Information System (INIS)
The present invention concerns a method of evaluating corrosion resistance of a zirconium alloy easily and in a short period of time. An anode polarization curve of the zirconium alloy is measured to obtain an anode polarization curve expressed by logarithm. The curve is converted to a potential-current density curve expressed by absolute values. The peak area in the curve of the converted potential-current density is indicated by numerical values. Further, the corrosion resistance of the zirconium alloy is evaluated based on the peak area converted into the numerical values as a reference. This method is based on the finding that the peak area has a close relation with nodular corrosion resistance, and the corrosion resistance can be judged with respect to a specific zircaloy-2. (T.M.).
1993-03-26
Electron-impact excitation of Si"3"+(3s#->#3p) using a merged-beam electron-energy-loss technique
International Nuclear Information System (INIS)
For the first time, absolute cross sections for electron-impact excitation of a multiply charged ion have been measured using an electron-energy-loss technique. Cross sections for e+Si"3"+(3s "2S_1_/_2)#->#e+Si"3"+(3p "2P_1_/_2_,_3_/_2)-8.88 eV have been measured with an accuracy of #+-#20% (at 90% confidence level) over a narrow energy range (#+-#0.6 eV) about the threshold energy with an energy resolution of 0.2 eV. Results are in good agreement with close-coupling calculations.
International Nuclear Information System (INIS)
We study the dynamical evolution of a scalar field coupling to Einstein's tensor in the background of a Reissner-Nordstroem black hole. Our results show that the coupling constant #eta# imprints in the wave dynamics of a scalar perturbation. In the weak coupling, we find that with the increase of the coupling constant #eta# the real parts of the fundamental quasinormal frequencies decrease and the absolute values of imaginary parts increase for fixed charge q and multipole number l. In the strong coupling, we find that for l#not =#0 the instability occurs when #eta# is larger than a certain threshold value #eta#_c which deceases with the multipole number l and charge q. However, for the lowest l=0, we find that there does not exist such a threshold value and the scalar field always decays for arbitrary coupling constant.
2010-10-15
Energy Technology Data Exchange (ETDEWEB)
This paper describes the structure of dynamic neuronal ensembles (DNEs). DNEs represent a new paradigm for learning, based on biological neural networks that use variable structures. We present a computational neural element that demonstrates biological neuron functionality such as neurotransmitter feedback absolute refractory period and multiple output potentials. More specifically, we will develop a network of neural elements that have the ability to dynamically strengthen, weaken, add and remove interconnections. We demonstrate that the DNE is capable of performing dynamic modifications to neuron connections and exhibiting biological neuron functionality. In addition to its applications for learning, DNEs provide an excellent environment for testing and analysis of biological neural systems. An example of habituation and hyper-sensitization in biological systems, using a neural circuit from a snail is presented and discussed. This paper provides an insight into ...
1996-12-31
Delayed neutron yields: Time dependent measurements and a predictive model
Energy Technology Data Exchange (ETDEWEB)
The delayed neutrons from neutron-induced fission in /sup 232/U, /sup 237/Np, /sup 238/Pu, /sup 241/Am, /sup 242/Am/sup m/, /sup 245/Cm, and /sup 249/Cf were studied for the first time; those from /sup 232/Th, /sup 233/U, /sup 235/U, /sup 238/U, /sup 239/Pu, /sup 241/Pu, and /sup 242/Pu were measured again. The data were used to develop an expression for the prediction of the absolute delayed neutron yield, and the prediction of delayed neutron emission with time. This approach accurately predicts observed delayed neutron yields and decay characteristics. A fission product yield model was used in conjunction with delayed neutron emission probability to analytically predict delayed neutron characteristics. The results of this analysis are in excellent agreement with experimental values.
1981-03-01
Current waste-management practices and operations at Oak Ridge National Laboratory, 1982
Energy Technology Data Exchange (ETDEWEB)
The need for efficient management of industrial chemical wastes, especially those considered hazardous or radioactive, is receiving increased attention in the United States. During the past five years, several federal laws have addressed the establishment of stronger programs for the control of hazardous and residual wastes. At a facility such as Oak Ridge National Laboratory (ORNL), an efficient waste management program is an absolute necessity to ensure protection of human health and compliance with regulatory requirements addressing the treatment and disposal of hazardous, nonhazardous, and radioactive wastes. This report highlights the major regulatory requirements under which the Laboratory must operate and their impact on ORNL facilities. Individual waste streams, estimates of quantities of waste, and current waste management operations are discussed.
1982-09-01
Carbon dioxide adsorption on carbon nanomaterials
British Library Electronic Table of Contents (United Kingdom)
The adsorption of CO2 on a number of activated carbons, thermal carbon black, and oxide materials at 195 K was studied using static and dynamic techniques. The landing surface areas ?(CO2) ? 0.19 nm2 on thermal carbon black and the absolute values of sorption for P/P 0 < 0.4 were determined. The density of adsorbed CO2 in the micropore volume was estimated at ?(CO2) = 0.91 g/cm3. It was demonstrated that the previously found effect of a weakening of the sorption interaction of nitrogen molecules with thin-walled materials (which manifested itself in an analysis of sorption isotherms by a comparative method) was pronounced to a lesser degree for the sorption of CO2. At the same time, the presence of supermicropores in activated carbon samples resulted in overestimated values of surface area...
2010-01-01
Bioprocess control from a multivariate process trajectory.
A multivariate bioprocess control approach, capable of tracking a pre-set process trajectory correlated to the biomass or product concentration in the bioprocess is described. The trajectory was either a latent variable derived from multivariate statistical process monitoring (MSPC) based on partial least squares (PLS) modeling, or the absolute value of the process variable. In the control algorithm the substrate feed pump rate was calculated from on-line analyzer data. The only parameters needed were the substrate feed concentration and the substrate yield of the growth-limiting substrate. On-line near-infrared spectroscopy data were used to demonstrate the performance of the control algorithm on an Escherichia coli fed-batch cultivation for tryptophan production. The controller showed good ability to track a defined biomass trajectory during varying process dynamics. The robustness of the control was high, despite significant external disturbances on the ...
2003-09-05
British Library Electronic Table of Contents (United Kingdom)
ObjectivesVaricocele is a common cause of infertility, and varicocele-associated testicular hypotrophy has been described as a potential cause of decreased semen quality. We investigated the relationship between testicular hypotrophy and poor semen quality in infertile men with varicoceles. We hypothesized that bilateral hypotrophy is required before the semen quality is severely impaired.MethodsWe retrospectively identified consecutive patients with palpable varicoceles undergoing an infertility evaluation at a single academic center. Each patient was evaluated by the same clinician with history and physical examination. Testicular hypotrophy was defined as a size discrepancy of greater than 3 mL or an absolute size of less than 14 mL. Multivariate logistic regression analysis was used to...
2008-01-01
British Library Electronic Table of Contents (United Kingdom)
We present an empirical model for periodic variations of diurnal and sub-diurnal Earth rotation parameters (ERPs) that was derived based on the transformation of normal equation (NEQ) systems of Very Long Baseline Interferometry (VLBI) observing sessions. NEQ systems that contain highly resolved polar motion and UT1-TAI with a temporal resolution of 15?min were generated and then transformed to the coefficients of the tidal ERP model to be solved for. To investigate the quality of this model, comparisons with empirical models from the Global Positioning System (GPS), another VLBI model and the model adopted by the conventions of the International Earth Rotation and Reference Systems Service (IERS) were performed. The absolute coefficients of these models agree almost completely within 7.5?...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
The /sup 252/Cf-source-driven noise analysis method determines the subcriticality of a system containing fissionable material from the ratio of cross power spectral densities between the detectors that detect particles from the fission process and between these detectors and an ionization chamber containing a spontaneously fissioning neutron source which provides neutrons to induce fission in the system. This method has two advantages: (1) a calibration is not required and thus subcriticality can be determined from measurements only on the subcritical system of interest, and (2) the subcriticality is independent of the type of detector or its efficiency. These properties of this technique are illustrated by measurements.
1984-01-01
A note on the examination of isospin effects in multi-dimensional Langevin fission dynamics
British Library Electronic Table of Contents (United Kingdom)
In [W. Ye, F. Wu, H.W. Yang, Phys. Lett. B 647 (2007) 118] prescission protons and ? particles of high-isospin 206Pb were shown to be almost independent of the dissipation strength Formula Not Shown . Subsequently, in [P.N. Nadtochy, et al., Phys. Lett. B 685 (2010) 258] prescission light charged particles (LCPs) were shown to have approximately the same sensitivity as neutrons to Formula Not Shown for 206Pb and 204Hg nuclei. In this Letter we point out that the reason for the apparent contradictory conclusions is that the authors in the latter did not compute the changes in the absolute yields of prescission LCPs multiplicities with increasing Formula Not Shown and compare them with typical experimental uncertainties. It is shown that the expected changes are very small in the case of ne...
2011-01-01
A diffusion criterion of the crystal-liquid phase transition
A diffusion criterion of the crystal-liquid phase transition (PT) is proposed according to which the PT begins when the E d/ k b ratio reaches a threshold value of E d( s)/ k b T m, where E d is the self-diffusion energy, k B is the Boltzmann constant, T is the absolute temperature, and E d( s) is the self-diffusion energy in the solid phase at the melting temperature T m. It is shown that this criterion is a generalization of the Lindemann criterion and is applicable both to solids exhibiting normal melting and to those melting with a decrease in the specific volume. Based on the new criterion, it is possible to explain the relation T N < T m, where T N, is the crystallization onset temperature. The results of calculations of the T N/ T m ratio well coincide with experimental data.
2007-10-01
A brief historical development of classical mathematics before the Renaissance
British Library Electronic Table of Contents (United Kingdom)
'If you wish to foresee the future of mathematics our proper course is to study the history and present condition of the science.' Henri Poincare 'It is India that gave us the ingenious method of expressing all numbers by ten symbols, each symbol receiving a value of position, as well as an absolute value. We shall appreciate the grandeur of the achievement when we remember that it escaped the genius of Archimedes and Apollonius.' P.S. Laplace 'The Greeks were the first mathematicians who are still 'real' to us today. Oriental mathematics may be an interesting curiosity, but Greek mathematics is the real thing. The Greek first spoke of a language which modern mathematicians can understand.' G.H. Hardy This article deals with a short history of mathematics and mathematical scientists during...
2011-01-01
Quantitative bone scintigraphy. A study in patients with prostatic carcinoma
International Nuclear Information System (INIS)
Quantitative bone scintigraphy was performed in patients with prostatic carcinoma before orchiectomy as well as two weeks, two and six months after operation. The count rate was recorded as serial gamma camera images over the lower thoracic and all lumbar vertebrae from 1 to 240 min and at 24 h after injection of "9"9"Tc"m-MDP. In almost all abnormal vertebrae an increased count rate was observed within one hour after injection. Most of the vertebrae which were considered normal at 4 h after injection, but had an increased 24h/4h ratio developed into abnormal vertebrae later in the study. The patients with normal bone scintigrams showed no change in "9"9Tc"m-MDP uptake during the study. The reproducibility of quantitative bone scintigraphy was found to be #+-# 7% (1 SD). In response to therapy, most of the patients with abnormal bone scintigrams showed an increase in count rate two weeks after operation followed by a ...
1985-06-02
On the continuous measurement of the cosmic-ray intensity, 2
International Nuclear Information System (INIS)
Since November 1971, the cosmic ray neutron intensity has been measured continuously with 3NM-64 neutron monitor at Fukushima University (140"029'E geographic longitude, 37"045'N geographic latitude, 27.6"0N geomagnetic latitude and 10.55 GV cut-off rigidity). After the neutron monitor had been operated during the period of fourteen months at the ground floor of 3-storied ferro-reinforced concrete building, it was removed to the prefabricated house near the old position of the monitor at January 1973. As a result of the removement of the monitor, the expected values for the counting rate and barometric coefficient of our neutron monitor were obtained, 7.5x10"4 cph and -0.64% mb respectively. The monitor was moved out into a new place, the statistical accuracy of counting rate is altered from 0.44% (hourly counting rate) to 0.36%. It can be considered that there is no effect of concrete building near the monitor, for reason ...
Energy Technology Data Exchange (ETDEWEB)
A technique involving shifting of core fuel loadings was investigated as a method for reducing the neutron flux at points of high damage accumulation in the pressure vessel wall of a light water reactor. Calculations were run for six types of commercial generic PWR. Information is provided on the progress being made to develop and apply the Solid State Track Recorder (SSTR) method for in-situ in- and ex-vessel measurements of neutron exposure parameter values, such as fluence (E > 1.0 MeV) and dpa in iron. A new technique of quantitative track counting, the Buffon needle method, is advanced. It is based on random sampling of the SSTR surface. A desensitized etching technique was developed that resulted in an excellent differential energy response for alpha particles in the 3- to 14-MeV energy range. The optical efficiency of Muscovite mica for manual fission track counting is being redetermined to form a data base for comparison with ...
1982-10-01
Energy Technology Data Exchange (ETDEWEB)
A technique has been developed at the Idaho National Engineering Laboratory to sum high resolution gamma-ray pulse spectra from systems with multiple Ge detectors. Lockheed Martin Idaho Technologies Company operates a multi-detector spectrometer configuration at the Stored Waste Examination Pilot Plant facility which is used to characterize the radio nuclide contents in waste drums destined for shipment to Waste Isolation Pilot Plant. This summing technique was developed to increase the sensitivity of the system, reduce the count times required to properly quantify the radionuclides and provide a more consistent methodology for combining data collected from multiple detectors. In spectrometer systems with multiple detectors looking at non homogenous waste forms it is often difficult to combine individual spectrum analysis results from each detector to obtain a meaningful result for the total waste container. This is particularly true when the ...
1997-05-01
Experimental study of nanoparticles penetration through commercial filter media
Energy Technology Data Exchange (ETDEWEB)
In this study, nanoparticle penetration was measured with a wide range of filter media using silver nanoparticles from 3 nm to 20 nm at three different face velocities in order to define nanoparticle filtration characteristics of commercial fibrous filter media. The silver particles were generated by heating a pure silver powder source via an electric furnace with a temperature of 870 deg. C, which was found to be the optimal temperature for generating an adequate amount of silver nanoparticles for the size range specified above. After size classification using a nano-DMA, the particle counts were measured by an Ultrafine Condensation Particle Counter (UCPC) both upstream and downstream of the test filter to determine the nanoparticle penetration for each specific particle size. Particle sampling time continued long enough to detect more than 10{sup 5} counts at the upstream and 10 counts at the downstream sampling point so ...
2007-01-15
Experimental studies of compact real-time neutron dosimeters
International Nuclear Information System (INIS)
Full text: Semiconductor detectors coated with boron or lithium compounds have been studied for neutron detection for decades but, until recently, have been limited to thermal neutron detection efficiencies of less than 5%. We reported previously on development and simulation studies of perforated detectors whose perforations are filled with neutron-reactive material in order to produce higher detection efficiencies. Incorporation of bare and cadmium-backed detectors into battery-powered devices with low-power electronics enables us to produce compact personal neutron dosimeters that provide LED readout of counts, which can be related approximately to neutron dose. We report here on experimental studies with such compact devices; devices capable of direct readout in dose units are anticipated. The thermal and epithermal neutron flux densities from the tangential beam tube of the TRIGA Mark II reactor at Kansas State University were measured. Then, thermoluminescent ...
2008-06-01
Determination of sodium in biological samples by instrumental neutron activation analysis
International Nuclear Information System (INIS)
Sodium is one of the most essential elements needed for metabolic processes amongst human beings. It is consumed in the form of sodium chloride but it is also present in edible plant leaves. Sodium is mostly analyzed by flame photometric method, a destructive and time consuming technique. Sodium has been determined in some green leave vegetables samples-palak, radish, khatta palak (ambat chuka), chaulai leaves, chauli bean covers and its seeds by instrumental neutron activation analysis. The method involves irradiation of samples with thermal neutrons from "2"4"1Am-Be source and counting "2"4Na activity (half life 15 hr) from the reaction "2"3Na(n,#gamma#) "2"4Na. Activity due to 1.37 MeV photopeak was counted with a NaI(Tl) crystal coupled to gamma ray spectrometer. Green leaves of the vegetables were thoroughly washed, dried at constant temperature and powdered. Bowen's Kale powder was used as standard for measuring sodium abundances. About ...
1981-05-01
Transport and superconducting properties of RNi_2B_2C (R=Y, Lu) single crystals
International Nuclear Information System (INIS)
The in-plane resistivity, in-plane absolute thermopower, and upper critical field measurements are reported for single-crystal samples of YNi_2B_2C and LuNi_2B_2C superconductors. The in-plane resistivity shows metallic behavior and varies approximately linearly with temperature near room temperature (RT) but shows nearly quadratic behavior in temperature at low temperatures. The YNi_2B_2C and LuNi_2B_2C single-crystal samples exhibit large transverse magnetoresistance (#approx#6 8% at 45 kOe) in the ab plane. The absolute thermopower S(T) is negative from RT to the superconducting transition temperature T_c. Its magnitude at RT is a few times of the value for a typical good metal. S(T) is approximately linear in temperature between #approx#150 K and RT. Extrapolation to T=0 gives large intercepts (few #mu#V/K) for both samples suggesting the presence of a much larger knee than would be expected from electron-phonon interaction renormalization ...
Reduced resolution polarimetric imagery characterization of the 1990 Galveston Bay oil spill
Energy Technology Data Exchange (ETDEWEB)
Low resolution visual polarimetric photographic imagery of the Galveston Bay oil spill from a tanker accident on July 28, 1990 was obtained and analyzed. The low resolution imagery (30 to 100 meters) was obtained concurrently with high resolution (1 meter), and is representative of what would be seen by a polarimetric satellite. Orthogonal red-green-blue (RGB) polarimetric images obtained with color photography were digitized by KODALUX on to a CD ROM. These polarimetric images were then used to calculate the percent polarization. The positive and negative percent polarized radiation scattered by each of the sea surface waves is seen individually in high resolution imagery. (Percent polarization is defined as positive when the dominant radiation is perpendicular to the plane of incidence and negative when it is parallel). The analysis of low resolution polarimetry is approached in a different manner than high resolution; in high resolution, individual waves are imaged and the ...
1997-06-01
Phenomenological analysis of heavy hadron lifetimes
International Nuclear Information System (INIS)
A phenomenological analysis of lifetimes of bottom and charmed hadrons within the framework of the heavy quark expansion is performed. The baryon matrix element is evaluated using the bag model and the nonrelativistic quark model. We find that bottom-baryon lifetimes follow the pattern #tau#(#OMEGA#_b)#approx =##tau#(#XI#_b"-)>#tau#(#LAMBDA#_b)#approx =##tau#(#XI#_b"0). However, neither the lifetime ratio #tau#(#LAMBDA#_b)/#tau#(B_d) nor the absolute decay rates of the #LAMBDA#_b baryon and B mesons can be explained. One way of solving both difficulties is to allow the presence of linear 1/m_Q corrections by scaling the inclusive nonleptonic width with the fifth power of the hadron mass m_H__Q rather than the heavy quark mass m_Q. The hierarchy of bottom baryon lifetimes is dramatically modified to #tau#(#LAMBDA#_b)>#tau#(#XI#_b"-)>#tau#(#XI#_b"0)>#tau#(#OMEGA#_b): The longest-lived #OMEGA#_b among bottom baryons in the OPE prescription now becomes the ...
IMRT verification by three-dimensional dose reconstruction from portal beam measurements
International Nuclear Information System (INIS)
A method of reconstructing three-dimensional, in vivo dose distributions delivered by intensity-modulated radiotherapy (IMRT) is presented. A proof-of-principle experiment is described where an inverse-planned IMRT treatment is delivered to an anthropomorphic phantom. The exact position of the phantom at the time of treatment is measured by acquiring megavoltage CT data with the treatment beam and a research prototype, flat-panel, electronic portal imaging device. Immediately following CT imaging, the planned IMRT beams are delivered using the multiple-static field technique. The delivered fluence is sampled using the same detector as for the CT data. The signal measured by the portal imaging device is converted to primary fluence using an iterative phantom-scatter estimation technique. This primary fluence is back-projected through the previously acquired megavoltage CT model of the phantom, with inverse attenuation correction, to yield an input fluence map. The input fluence maps are ...
2002-08-01
Future needs and requirements for AMS "1"4C standards and reference materials
International Nuclear Information System (INIS)
"1"4C measurement uses a number of standards and reference materials with different properties. Historically the absolute calibration of "1"4C measurement was tied to 1890 wood, through the 'primary' standard of NBS-OxI (produced by the National Bureau of Standards, now NIST - National Institute of Standards and technology) subsequently replaced by NBS-OxII. These are both internationally calibrated and certified materials, whose "1"4C activities are known absolutely. A second tier of materials, often called secondary standards or reference materials, and including internationally recognised materials such as ANU-sucrose (now also IAEA-C6), Chinese - sucrose and the IAEA C1-C6 series, augmented by additional oxalic acid samples are also used routinely. The activity of these materials has been estimated from large numbers of measurements made by many laboratories. Recently, further natural materials from the Third and Fourth International ...
2004-08-01
Dose verification using a pelvic phantom in high dose rate (HDR) brachytherapy
Energy Technology Data Exchange (ETDEWEB)
High dose rate (HDR) brachytherapy for treating a cervix carcinoma has become popular, because it eliminates many of the problems associated with conventional brachytherapy. In order to improve the clinical effectiveness with HDR brachytherapy, a dose calculation algorithm, optimization procedures, and image registrations need to be verified by comparing the dose distributions from a planning computer and those from a humanoid phantom. In this study, the humanoid phantom was fabricated in order to verify the absolute doses and the relative dose distributions. The measured doses from the humanoid phantom were then compared with the treatment planning system for the dose verification. The humanoid phantom needs to be designed such that the dose distributions can be quantitatively evaluated thermoluminescent dosimeter (TLD) chips with a dimension of 1/8 and film dosimetry with a spatial resolution of <1 mm used to measure the radiation dosages in the phantom. ...
2003-07-01
Clinical studies on cancer of the tongue
Energy Technology Data Exchange (ETDEWEB)
Thirty-nine previously untreated patients with squamous cell carcinoma of the tongue were treated by irradiation or a combination of irradiation and surgery, with or without chemotherapy, between January 1971 and December 1980. All of the patients had a follow-up period of at least nine years. Twenty-two patients were men and 17 were women. The average age was 50.1 years, with a range of 30 to 74 years. The absolute five-year survival rate was 82.1% and the cumulative ten-year survival rate 76.9% for these 39 patients. Cervical node metastases were clinically found on admission in 14 patients whose five-year survival rate was 64.3%, whereas it was 92.0% for 25 patients without metastasis. The absolute five-year survival rate decreased from 92.3% for patients with stage I lesions to 90.9%, 87.5% and 42.9% for those with stage II, stage III and stage IV lesions, respectively. Most of the patients received external irradiation and intraoral ...
1990-12-01
Energy Technology Data Exchange (ETDEWEB)
Spectroscopic constants and absolute intensities from more than 2150 transitions belonging to 52 bands of 7 isotopic species of carbon dioxide have been determined using a multispectrum nonlinear least-squares fitting technique. The spectral data (0.01 cm{sup -1} resolution) were obtained at room temperature and low pressure (<10 Torr) using the McMath-Pierce Fourier transform spectrometer of the National Solar Observatory on Kitt Peak, Arizona. A natural sample of carbon dioxide with absorption path lengths between 24 and 385m were used in recording the spectra. The first measurements have been made of the theoretically predicted 2v{sub 2}{sup 2} 2+v{sub 3} {open_quotes}forbidden{close_quotes} band of {sup 12}CO{sub 2}. Two bands which have not been predicted so far, one belonging to {sup 13}CO{sub 2} and the other to {sup 13}C{sup 16}O{sup 18}O, have been identified. The measured line intensities obtained for each band have been analyzed to determine the ...
1995-12-31
Energy Technology Data Exchange (ETDEWEB)
In this experiment, we measured the detection efficiency of gamma-scanning system of Irradiated Materials Examination Facility (IMEF) in Korea Atomic Energy Research Institute(KAERI) for the spent PWR fuel and activity known sources with high activity. We measured the absolute detection efficiency of gamma scanning system of IMEF to the {sup 137}Cs-source with 10.4 GBq and {sup 60}Co source with 25.9 GBq High-activity sources as standard sources, and a fuel burned in the KORI -1 reactor of the Kori Nuclear power plant. In analyzing, we used three peeks those were the 661.64 keV peak form {sup 137} Cs 1173.23 and 1332.51 keV{sup 60} Co sources, and 14 peaks of {sup 134}Cs and {sup 154}Eu on the spent fuel gamma spectrum which are in the energy range from 500 to 1,600 keV. We find second order equations for detection efficiency by using our experimental results. The equation show that the detection efficiency of gamma scanning system for 1 MeV gamma-ray is ...
2003-10-01
International Nuclear Information System (INIS)
In this experiment, we measured the detection efficiency of gamma-scanning system of Irradiated Materials Examination Facility (IMEF) in Korea Atomic Energy Research Institute(KAERI) for the spent PWR fuel and activity known sources with high activity. We measured the absolute detection efficiency of gamma scanning system of IMEF to the "1"3"7Cs-source with 10.4 GBq and "6"0Co source with 25.9 GBq High-activity sources as standard sources, and a fuel burned in the KORI -1 reactor of the Kori Nuclear power plant. In analyzing, we used three peeks those were the 661.64 keV peak form "1"3"7 Cs 1173.23 and 1332.51 keV"6"0 Co sources, and 14 peaks of "1"3"4Cs and "1"5"4Eu on the spent fuel gamma spectrum which are in the energy range from 500 to 1,600 keV. We find second order equations for detection efficiency by using our experimental results. The equation show that the detection efficiency of gamma scanning system for 1 MeV gamma-ray is 2.82217x10"-"6 % for the C3 ...
2003-10-01
International Nuclear Information System (INIS)
The compost bioreactor ('anaerobic cell') components of three composite passive remediation systems constructed to treat acid mine drainage (AMD) at the former Wheal Jane tin mine, Cornwall, UK were studied over a period of 16 months. While there was some amelioration of the preprocessed AMD in each of the three compost bioreactors, as evidenced by pH increase and decrease in metal concentrations, only one of the cells showed effective removal of the two dominant heavy metals (iron and zinc) present. With two of the compost bioreactors, concentrations of soluble (ferrous) iron draining the cells were significantly greater than those entering the reactors, indicating that there was net mobilisation (by reductive dissolution) of colloidal and/or solid-phase ferric iron compounds within the cells. Soluble sulfide was also detected in waters draining all three compost bioreactors which was rapidly oxidised, in contrast to ferrous iron. Oxidation and hydrolysis of iron, together with ...
2005-02-01
Uptake of Pb by human skeleton and comparative metabolism of Pb and alkaline earth elements
Energy Technology Data Exchange (ETDEWEB)
Measurements of the retention of /sup 47/Ca and of /sup 203/Pb were made following their administration by intravenous injection. Translocation to bone was measured by ..gamma.. counting the feet of subjects. Uptake by bone of /sup 203/Pb was comparatively slow and extrapolation to the whole skeleton indicated that 20% of the dose has been taken up within 20 days. By time, a similar fraction of the dose has been excreted in urine. Uptake by bone of /sup 47/Ca was about 1.5-2 times the amount excreted in urine. Both the uptake by bone, and its excretion in urine, were more rapid than that of /sup 203/Pb due to the greater attachment of the latter to red blood cells. However, the plasma clearance rate for Pb, like that of Sr, was greater than that of Ca.
1984-12-01
Transuranic separation using organophophorus extractants adsorbed onto superparamagnetic carriers.
Energy Technology Data Exchange (ETDEWEB)
Polymeric coated ferromagnetic carriers with an absorbed layer of octyl(phenyl)-N,N-diisobutylcarbamoylmethylphosphine oxide (CMPO) diluted by tributyl phosphate (TBP) are being evaluated for application in the separation and the recovery of low concentrations of americium, plutonium, and uranium from nuclear waste solutions. Due to their chemical nature, these extractants selectively complex americium and plutonium contaminants onto the particles and the complexed particles can be recovered from the solution using a magnet. Physical and chemical characterization of the extractant-absorbed particles were performed by gamma and liquid scintillation counting, scanning electron microscopic (SEM) micrograph, and other physical measurements. Plutonium, americium, and uranium separations have been performed at various HNO{sub 3} and HCl concentrations. Parameters were studied to determine the limitations and capacity of the process. The status of the chemistry and ...
1998-10-07
Total cross sections of ultracold neutron interactions with some gases
Energy Technology Data Exchange (ETDEWEB)
Measurement results of total interaction cross sections averaged by the spectrum of ultracold neutrons (UCN) within the rate range from 3.2 to 5.7 m/s at the temperatures of 80 and 300 K for the following gases: hydrogen, parahydrogen, helium-4, nitrogen, neon, argon, xenon are presented. The experiment has been conducted conducted in the facility for UCN extraction, mounted in the radial channel of the WWR-K reactor. Experimental dependences of UCN counting rate on pressure of the investigated gases in the chamber varying from 0 to 1.5x10/sup 3/ torr are presented graphically. The measured total cross sections mainly satisfactorily agree with calculations, divergences are observed only for hydrogen and xenon.
1981-11-01
The investigations on K and L X-ray fluorescence parameters of gold compounds
British Library Electronic Table of Contents (United Kingdom)
The study aimed to determine the chemical effects on the K and L X-ray intensity ratios and the K and L X-ray production cross sections for gold compounds. The K shell fluorescence yields and L shell average yields were also investigated. The samples were excited by 59.5keV ?-rays from an 241Am annular radioactive source and 123.6keV ?-rays from a 57Co annular radioactive source. K and L X-rays emitted from samples were counted by an Ultra-LEGe detector with a resolution of 0.150keV at 5.9keV. The experimental values were compared with theoretical, the semi-empirical and other experimental values.
2010-01-01
The application of the neutron time-of-flight technique for real-time diffraction studies
Energy Technology Data Exchange (ETDEWEB)
Real-time neutron powder diffraction and small-angle scattering techniques have been developed on the TOF diffractometer DN-2 at the IBR-2 pulsed reactor at JINR (Dubna) with a total flux on the sample of 10{sup 7} neutrons cm{sup -2}s{sup -1} and a resolution of about 1%. A special arrangement of the detector system ensures a high counting rate of diffracted neutrons. Depending upon sample type and experimental conditions, the measuring time t{sub s} of one neutron pattern varies from a few minutes to several seconds. The performance of the diffractometer is discussed and typical data are shown to demonstrate current achievements using real-time techniques at a pulsed reactor. (orig.).
1991-12-01
The application of the neutron time-of-flight technique for real-time diffraction studies
International Nuclear Information System (INIS)
Real-time neutron powder diffraction and small-angle scattering techniques have been developed on the TOF diffractometer DN-2 at the IBR-2 pulsed reactor at JINR (Dubna) with a total flux on the sample of 10"7 neutrons cm"-"2s"-"1 and a resolution of about 1%. A special arrangement of the detector system ensures a high counting rate of diffracted neutrons. Depending upon sample type and experimental conditions, the measuring time t_s of one neutron pattern varies from a few minutes to several seconds. The performance of the diffractometer is discussed and typical data are shown to demonstrate current achievements using real-time techniques at a pulsed reactor. (orig.).
1991-12-01
System and method for non-destructive evaluation of surface characteristics of a magnetic material
Energy Technology Data Exchange (ETDEWEB)
A system and a related method for non-destructive evaluation of the surface characteristics of a magnetic material. The sample is excited by an alternating magnetic field. The field frequency, amplitude and offset are controlled according to a predetermined protocol. The Barkhausen response of the sample is detected for the various fields and offsets and is analyzed. The system produces information relating to the frequency content, the amplitude content, the average or RMS energy content, as well as count rate information, for each of the Barkhausen responses at each of the excitation levels applied during the protocol. That information provides a contiguous body of data, heretofore unavailable, which can be analyzed to deduce information about the surface characteristics of the material at various depths below the surface.
1994-05-17
Subcritical measurements with a cylindrical tank of Pu-U nitrate
Energy Technology Data Exchange (ETDEWEB)
This series of measurements with a mixed Pu-U nitrate solution (280 g Pu/liter, 180 g U/liter) in a 35.54-cm-diam cylindrical tank provides a wide variety of experimental data for subcritical configurations that can be used to verify calculational methods and nuclear data. The Pu contained 7.85 wt% {sup 240}Pu and the uranium was natural uranium. The measurements performed were: inverse count rate, prompt neutron decay constants, inverse kinetics, and frequency analysis by the {sup 252}Cf source driven method. These data are presented in sufficient detail that the results of the experiments can be calculated directly. For purposes of extrapolating to the delayed critical height the ratio of spectral densities was linear with height and thus provided the best estimate of critical height.
1997-04-01
Energy Technology Data Exchange (ETDEWEB)
Elemental analysis of some medicinal plants used in the Indian Ayurvedic system was performed by employing instrumental neutron activation analysis (INAA) and atomic absorption spectroscopy (AAS) techniques. The samples were irradiated with thermal neutrons in a nuclear reactor and the induced activity was counted by gamma ray spectrometry using an efficiency calibrated high resolution high purity germanium (HPGe) detector. Most of the medicinal plants were found to be rich in one or more of the elements under study. The variation in elemental concentration in same medicinal plants samples collected in summer, winter and rainy seasons was studied and the biological effects of these elements on human beings are discussed. (orig.)
2009-07-01
British Library Electronic Table of Contents (United Kingdom)
ObjectiveTo study a method of chemical sterilization and its efficacy in adult male stray dogs.MethodsSterilization was performed 45 days after a single bilateral intratesticular injection of calcium chloride (CaCl2) at the doses of 5, 10, 15 or 20 mg per testis per kg body weight.ResultsHistomorphological measures of testes showed total necrosis of testicular tissue at 45 days after an injection of either 10 or 15 or 20 mg CaCl2 along with fibrosis and hyalinization in seminiferous tubules and interstitial spaces. Infiltration of leucocytes was also observed with the 10- or 15-mg dose. Disintegration of germ cell arrangement in seminiferous tubules and washing out of germ cells from the tubules were noted with the 5-mg dose. Relative organ weight, epididymal sperm count, plasma and intrat...
2007-01-01
Short-term radon measurements in the workplace
Energy Technology Data Exchange (ETDEWEB)
A novel envelope-type radon monitor has been used for short-term (as little as 1 week) radon concentration measurements in a workplace environment. The commercially available LR-115 type II damage track detector was used in this study and the chemically etched sheets were spark counted. The measurements were made over a period of 1 year in a workplace consisting of three adjacent rooms situated in the lower ground level of multistorey office building in Rome, Italy. The variations of the radon concentration are from [approx] 20 to [approx] 300 Bq m[sup -3] with averages of 130,81 and 73 Bq m[sup -3] for the three different rooms resulting in annual doses of [approx] 3.8, [approx] 2.4 and [approx] 2.2 mSv, respectively. (author) 2 figs., 9 refs.
1992-01-01
Self-diffusion of silicon in thin films of cobalt, nickel, palladium and platinum silicides
International Nuclear Information System (INIS)
Radioactive "3"1Si was used as a tracer to study silicon self-diffusion in thin film silicides of cobalt, nickel, palladium and platinum. The specimens were prepared by sequential electron beam evaporation of radioactive "3"1Si and of the metal onto cleaned silicon wafers. By vacuum annealing at the appropriate formation temperature a silicide about 250 nm thick containing a sharp radioactive band about 50 nm thick was generally formed. Subsequent heating above the formation temperature resulted in a spreading of the activity owing to silicon self-diffusion. Activity profiles in the silicides were measured by a combination of ion beam sputtering, radioactivity counting and Rutherford backscattering of charged nuclear particles. (orig.).
Resonant inelastic soft x-ray scattering of CdS: a two-dimensional electronic structure map approach
Energy Technology Data Exchange (ETDEWEB)
Resonant inelastic x-ray scattering (RIXS) with soft x-rays is uniquely suited to study the elec-tronic structure of a variety of materials, but is currently limited by low (fluorescence yield) count rates. This limitation is overcome with a new high-transmission spectrometer that allows to measure soft x-ray RIXS"maps." The S L2,3 RIXS map of CdS is discussed and compared with density functional calculations. The map allows the extraction of decay channel-specific"absorp-tion spectra," giving detailed insight into the wave functions of occupied and unoccupied elec-tronic states.
2008-09-24
Reborn quadrant anode image sensor
British Library Electronic Table of Contents (United Kingdom)
We describe a position sensitive photon counting microchannel plate based detector with an improved quadrant anode (QA) readout system. The technique relies on a combination of the four planar elements pattern and an additional fifth electrode. The charge cloud induced by single particle detection is split between the electrodes. The measured charge values uniquely define the position of the initial event. QA has been first published in 1976 by Lampton and Malina. This anode configuration was undeservedly forgotten and its potential has been hardly underestimated. The presented approach extends the operating spatial range to the whole sensitive area of the microchannel plate surface and demonstrates good linearity over the field of view. Therefore, the novel image sensor results in spatial...
2009-01-01
A position-sensitive event-counting electronic readout system for microchannel plates (MCPs) is described that offers the advantages of high spatial resolution and fast time resolution. The technique relies upon a four-quadrant electron-collecting anode located behind the output face of the microchannel plate, so that the electron cloud from each detected event is partly intercepted by each of the four quadrants. The relative amounts of charge collected by each quadrant depend on event position, permitting each event to be localized with two ratio circuits. A prototype quadrant anode system for ion, electron, and extreme ultraviolet imaging is described. The spatial resolution achieved, approx. =10 ..mu.., allows individual MCP channels to be distinguished. (AIP)
1976-11-01
International Nuclear Information System (INIS)
A position-sensitive event-counting electronic readout system for microchannel plates (MCPs) is described that offers the advantages of high spatial resolution and fast time resolution. The technique relies upon a four-quadrant electron-collecting anode located behind the output face of the microchannel plate, so that the electron cloud from each detected event is partly intercepted by each of the four quadrants. The relative amounts of charge collected by each quadrant depend on event position, permitting each event to be localized with two ratio circuits. A prototype quadrant anode system for ion, electron, and extreme ultraviolet imaging is described. The spatial resolution achieved, approx. =10 #mu#, allows individual MCP channels to be distinguished.
9472-01-01
Predictability, complexity and learning
We define {\\em predictive information} $I_{\\rm pred} (T)$ as the mutual information between the past and the future of a time series. Three qualitatively different behaviors are found in the limit of large observation times $T$: $I_{\\rm pred} (T)$ can remain finite, grow logarithmically, or grow as a fractional power law. If the time series allows us to learn a model with a finite number of parameters, then $I_{\\rm pred} (T)$ grows logarithmically with a coefficient that counts the dimensionality of the model space. While logarithmic growth of related information theoretic quantities has been found in previous work on learning, power law growth has not been seen in this context. We find that it is associated, for example, with the learning of infinite parameter (or nonparametric) models such as continuous functions with smoothness constraints. There are connections between the predictive information and measures of complexity that have been defined both in ...
2000-01-01
Potential of AMS for Quantifying Long-Lived Reaction Products
International Nuclear Information System (INIS)
Accelerator mass spectrometry (AMS) represents a powerful technique for the detection of long-lived radionuclides through ultra-low isotope ratio measurements. In many cases, counting atoms rather than decays yields much higher sensitivities. The potential of AMS will be demonstrated on typical radionuclides of interest with half-lives between some tens of years up to a hundred million years. The precise measurement of the 27Al(n,2n)26Al excitation function will be exemplified. Lack of information exists for a list of nuclides as pointed out by nuclear data requests. A brief overview on detection limits and some applications for selected long-lived radionuclides is given.
2005-05-24
Parental Subfecundity and Risk of Decreased Semen Quality in the Male Offspring: A Follow-up Study
British Library Electronic Table of Contents (United Kingdom)
A few studies have found poor semen quality in sons whose mothers have received fertility treatment, but it is unknown whether the poor semen quality is related to the infertility treatment or to infertility per se, for example, whether it is caused by hereditable factors. Using data from a population-based, Danish follow-up study conducted in 2005-2006, the authors of the present study examined whether sons of subfertile couples who had not received fertility treatment had poorer semen quality than sons of fertile couples. Among the 311 participants, an inverse association between parental waiting time to pregnancy and both semen volume and total sperm count was observed (p trend = 0.04 and p trend = 0.046, respectively). Semen volume in sons of subfertile parents (pregnant after ?1 ye...
2008-01-01
British Library Electronic Table of Contents (United Kingdom)
Abstract Preparation of antibacterial alginate films incorporating extruded white ginseng (EWG) extracts was attempted. The antibacterial effect of EWG extract on six selected food pathogenic bacteria was compared with the effect of red ginseng (RG) and white ginseng (WG) extracts. The EWG was processed in a twin-screw extruder with feed moisture of 20% and barrel temperature of 115 and 130C. The data obtained by agar diffusion assay demonstrated that the film containing 1-g/mL of EWG at barrel temperatures of 115 (EWG-115) and 130C (EWG-130) exhibited stronger antibacterial activity against the four strains of bacteria than the other extracts RG and WG. All films sampled showed reduction in bacteria cell counts (log cycle) compared with the control. After 24-h of incubation, Pseudomonas a...
2011-01-01
Nondestructive techniques for the control of conditioned radioactive wastes
International Nuclear Information System (INIS)
The final product of the radwaste conditioning process must satisfy certain requirments and physico-chemical properties in order to assure its safe long-term behaviour. Of course, the foreseen quality assurance and quality control should be conducted by means of non-destructive techniques. This work presents an over-view of various applicable non-destructive methods of analysis, showing their fields of investigation in testing waste packages, together with some arising practical problems. The most promising methods, such as eddy current testing, ultrasonic testing, #gamma#-scanning, #gamma#-spectroscopy, neutron counting and computerized tomography, are treated more deeply and some applications are presented. Particular attention is devoted to the development of a device based on computerized tomography; its essential components are reported and some design problems are also discussed.
2005-09-01
Mesenchymal stem cell transplantation for diffuse alveolar hemorrhage in SLE
British Library Electronic Table of Contents (United Kingdom)
Background. A 19-year-old girl was diagnosed with systemic lupus erythematosus, based on findings of arthritis, malar rash, positive antinuclear antibody test and high levels of antibodies to double-stranded DNA. Two months after diagnosis, the patient presented with a sudden drop in blood hemoglobin level. Several days later, she developed bloody sputum, rapidly progressive dyspnea and hypoxemia. High-resolution CT showed diffuse alveolar infiltrates in both lung fields.Investigations. Physical examination, complete blood count, erythrocyte sedimentation rate, urinalysis, 24-h urine protein excretion, fecal occult blood test, d-dimer test, acid hemolysis test, activated partial thromboplastin time and prothrombin time, direct and indirect Coombs tests, bone marrow smear, arterial blood ga...
2010-01-01
British Library Electronic Table of Contents (United Kingdom)
Maldives comprise some of the most characteristic and significant atoll systems, but the meiobenthic assemblages of these islands are still largely unknown. A study on meiofauna was conducted on three Maldivian sandy back-reef platforms differently exposed to stronger westerly monsoons. Clear high energy effects of the waves causing currents and erosions were observed at the completely exposed and isolated offshore reef of Thoddoo Island. Wave energy of medium intensity was confirmed at Rasdhoo by depositional structures (finolhu), while a medium to low energy level was recorded at Gulhi on the basis of the presence of a low sandy bar. The meiofaunal assemblage counted 17 major taxa. Copepods and nematodes were dominant, followed by platyhelminthes and polychaetes. The nematode assemblage ...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Mass and charge distributions of products from fission of sup(242m)Am induced by thermal neutrons have been investigated by means of the semiconductor spectrometry of ..gamma.. radiation from a mixture of non-separated fragment nuclei. Specimens of the fissible material have been irradiated in the vertical experimental channel of the research reactor then the measurements have been performed with calibrated semiconductor detectors. Three experiments with substantially different irradiation times have been performed to expand the nomenclature of the investigated fission products. The spectra of ..gamma.. radiation from the mixture of fission products, and time dependences of the counting rates at the total absorption peaks have been handled with computers. The obtained yields are compared with data of previous investigations performed with different experimental methods, as well as with the calculated one.
1985-03-01
Energy Technology Data Exchange (ETDEWEB)
The mass and charge distributions in an unseparated mix of fission product nuclei from thermal-neutron fission of /sup 242m/Am were studied through semiconductor gamma-ray spectrometry. Samples of the fissionable material under study were irradiated in a vertical irradiation tube of the MIFI IRT research reactor. Following irradiation, measurements were made on aperture-calibrated semiconductor detectors. For broader identification of fission fragment nuclides three experiments were conducted that differed substantially in irradiation duration. The spectrum of gamma radiation from the mix of fission products and the time dependences of count rate at total absorption peaks were analyzed on SM-4 and Iskra-226 computers. The values of yields obtained were compared with data of investigations conducted earlier with other experimental methods, and also with the results of calculations.
1985-03-01
Increased frequency of reproductive health problems among fathers of boys with hypospadias
British Library Electronic Table of Contents (United Kingdom)
BACKGROUNDSome studies have suggested an association between paternal subfertility and hypospadias among their sons, although the association has not been systematically investigated. We therefore compared male reproductive health among a group of fathers of boys with hypospadias and a group of fathers to normal children.METHODSA total of 64 fathers of boys with hypospadias participated; 349 partners of pregnant women served as a control group. All men delivered a semen sample, had a blood sample drawn, underwent a physical examination and completed a questionnaire.RESULTSFathers of boys with hypospadias had a significantly lower median sperm concentration (54.1 x 106/ml) (P = 0.004) and total sperm count (222.0 x 106) (P = 0.009) than the controls (81.2 and 326.0 x 106/ml). In addition, t...
2007-01-01
In vivo chicken model for peripheral intravascular human fibrin clot detection
Energy Technology Data Exchange (ETDEWEB)
A chicken model was prepared that provides a simple and economical method of evaluating the use of fibrin-specific monoclonal antibody 64C5 in the detection of peripheral vascular thrombi. Human fibrin was clotted in segments of a chicken's femoral artery and vein prior to intravenous injection of radioiodinated antibody 64C5. After a 3-hr perfusion time, the thrombosed and contralateral control segments of the vessels were excised and counted for radioactivity. The radiolabeled 64C5 uptake ratio of the thrombosed segment to the control segment was 5.4 +/- 1.2 (p less than 0.007) in the femoral artery, and 3.8 +/- 1.1 (p less than 0.02) in the femoral vein. This in vivo chicken model may also find application in studies of targeting agents for human fibrin.
1988-08-01
Implementation of projective measurements with linear optics and continuous photon counting
International Nuclear Information System (INIS)
We investigate the possibility of implementing a given projection measurement using linear optics and arbitrarily fast feedforward based on the continuous detection of photons. In particular, we systematically derive the so-called Dolinar scheme that achieves the minimum-error discrimination of binary coherent states. Moreover, we show that the Dolinar-type approach can also be applied to projection measurements in the regime of photonic-qubit signals. Our results demonstrate that for implementing a projection measurement with linear optics, in principle, unit success probability may be approached even without the use of expensive entangled auxiliary states, as they are needed in all known (near-)deterministic linear-optics proposals.
2005-02-01
Energy Technology Data Exchange (ETDEWEB)
A number of concrete culverts used to retrievably store drummed, dry, radioactive waste at the Savannah River Site (SRS), were suspected of containing ambiguous quantities of transuranic (TRU) nuclides. These culverts were assayed in place for Pu-239 content using thermal and fast neutron counting techniques. High resolution gamma-ray spectroscopy on 17 culverts, having neutron emission rates several times higher than expected, showed characteristic gamma-ray signatures of neutron emitters other than Pu-239 (e.g., Pu-238, Pu/Be, or Am/Be neutron sources). This study confirmed the Pu-239 content of the culverts with anomalous neutron rates and established limits on the Pu-239 mass in each of the 17 suspect culverts by in-field, non-intrusive gamma-ray measurements.
1990-01-01
Energy Technology Data Exchange (ETDEWEB)
A number of concrete culverts used to retrievably store drummed, dry, radioactive waste at the Savannah River Site (SRS), were suspected of containing ambiguous quantities of transuranic (TRU) nuclides. These culverts were assayed in place for Pu-239 content using thermal and fast neutron counting techniques. High resolution gamma-ray spectroscopy on 17 culverts, having neutron emission rates several times higher than expected, showed characteristic gamma-ray signatures of neutron emitters other than Pu-239 (e.g., Pu-238, Pu/Be, or Am/Be neutron sources). This study confirmed the Pu-239 content of the culverts with anomalous neutron rates and established limits on the Pu-239 mass in each of the 17 suspect culverts by in-field, non-intrusive gamma-ray measurements.
1990-12-31
British Library Electronic Table of Contents (United Kingdom)
ObjectivesTo assess the influence of epigallocatechin-3-gallate (EGCG) on the efficacy of ionizing radiation on prostate cancer cells because of the increased use of dietary interventions, especially by patients with prostate cancer. Radiotherapy is used to treat localized prostate cancer. Some people consume green tea (EGCG) as a chemopreventive agent against prostate cancer. Green tea can act as an antioxidant and induce superoxide dismutase enzymes, which could scavenge the free oxygen radicals generated by radiotherapy. MethodsProstate cancer cell line DU145 cells were treated with EGCG or radiotherapy, or both. Cell death was assessed using trypan blue cell counting, and apoptosis was confirmed by assessing poly (adenosine phosphate ribose) polymerase cleavage. The antioxidant potenti...
2011-01-01
Flow cytometric techniques were used to measure the cytological and biochemical damage to respiratory tract cells in animals exposed to particulates. Hamsters were exposed to raw and spent oil shale particulates and silica by intratracheal instillation. Exfoliated lung cells were obtained by sacrificing the animals and lavaging the respiratory tract posterior to the trachea with saline. Cell samples were fixed in ethanol and stained with mithramycin for fluorescence analysis of DNA content. DNA content distributions from hamsters exposed to spent oil shale and silica particulates showed atypical changes 28 to 35 days later. Cell counts and total numbers of macrophages, leukocytes, and epithelial cells in the lavage fluid also showed marked changes related to time after exposure.
1979-01-01
British Library Electronic Table of Contents (United Kingdom)
Purpose Evaluation of the all-trans retinoic acid (t-RA) effects on in vitro maturation (IVM) and in vitro fertilization (IVF) of immature mouse oocytes in the presence and absence of granulosa cell monolayer. Methods Denuded oocytes isolated from mice ovaries and matured in IVM medium alone (Control I), IVM medium in the presence of granulosa cells (Control II), IVM medium with t-RA (Experimental I) and IVM medium simultaneously with t-RA and granulosa cells (Experimental II). After 24?h, matured oocytes were fertilized in T6 medium and their development was followed until the blastocyst stage. Metaphase II oocytes ploidy were evaluated by chromosome counting. Results The t-RA group compared to the control groups showed no obvious abnormalities. Additionally maturation and embryo developm...
2011-01-01
Effects of pork/beef levels and various casings on quality properties of semi-dried jerky
British Library Electronic Table of Contents (United Kingdom)
The aim of this study was to investigate the effects of pork/beef levels and the casings on the quality properties of semi-dried jerky. The pork/beef levels in the four test formulations were as follows: T-1 (pork: beef=100:0), T-2 (95:5), T-3 (90:10), and T-4 (80:20). After tumbling for 30min with curing solution, the cured meats were stuffed into natural sheep casings, collagen casings, or cellulose casings, and then dried. The restructured jerky with cellulose casing had the lowest water content and the highest protein content, with no significant differences between various formulations. There were no significant differences among all formulations with regard to pH and total microbial counts, and jerky with cellulose casing had the lowest value of water activity. The processing yields ...
2008-01-01
British Library Electronic Table of Contents (United Kingdom)
The growth response, total hemocyte count (THC), respiratory burst (release of superoxide anion), phenoloxidase (PO) activity, superoxide dismutase (SOD) activity, nitric oxide synthase (NOS) activity as well as resistance to the pathogen Vibrio alginolyticus were measured in Litopenaeus vannamei, which had been fed diets supplemented with glycyrrhizin (the aqueous extract of licorice, Glycyrrhiza glabra, roots) at 0, 50, 100, 150, and 200 mg/kg of feed for 8 wk. In the feeding trial, there was no significant difference in survival rate (P > 0.05). Significant higher specific growth rate was observed in treatments with dietary glycyrrhizin than that in the control group (P < 0.05). Shrimp fed a diet with 200 mg/kg of glycyrrhizin had significant higher THC, PO activity, respiratory burst a...
2010-01-01
Do $\\psi$(4040), $\\psi$(4160) signal hybrid charmonium?
We suggest that \\psi (4040) and \\psi (4160) are strong mixtures of ground state hybrid charmonium at \\sim 4.1 GeV and the \\psi (3S) of conventional charmonium. The \\Gamma^{e^+e^-}, masses and total widths of the \\psi(4040) and \\psi(4160) are in accord with this hypothesis. Their hadronic decays are predicted to be dominated by the \\psi (3S) component and hence are correlated. In particular we find a spin counting relation \\Gamma (4160 \\rightarrow D_sD_s^*) \\sim 4 \\Gamma (4040 \\rightarrow D_sD_s) due to their common \\psi(3S) component. For D and D^* production, using \\psi(4040) branching ratios as input, we predict that the decay pattern of the \\psi(4160) will be very different from that of the \\psi(4040). These predictions may be tested in historical data from SPEAR, BES or at future Tau-Charm Factories.
1995-01-01
Dixon's Theorem and random synchronization
A transformation monoid on a set Omega is called synchronizing if it contains an element of rank 1 (that is, mapping the whole of Omega to a single point). In this paper, I tackle the question: given n and k, what is the probability that the submonoid of the full transformation monoid T_n generated by k random transformations is synchronizing? This question is analogous to Dixon's Theorem that two random permutations generate the symmetric or alternating group with high probability. Following the technique of Dixon's theorem, we need to analyse the maximal non-synchronizing submonoids of T_n. I develop a very close connection between transformation monoids and graphs, from which we obtain a description of non-synchronizing monoids as endomorphism monoids of graphs satisfying some very strong conditions. However, counting such graphs, and dealing with the intersections of their endomorphism monoids, seems difficult.
2011-01-01
Development of barcode system for internal dose monitoring
International Nuclear Information System (INIS)
In Tarapur Atomic Power Station unit-3 and 4, which is 540 MWe pressurized heavy water reactor, tritium is produced in primary heat transport system and moderator system. Tritium is a major contributor to the internal dose. Internal dose contributes about 30% of the collective dose. Internal dose monitoring and its control are important to control the collective dose. Estimation of internal dose is done by analysis of bioassay samples of radiation workers. In a month, about 7000 bioassay samples are analysed for the internal dose assessment during normal operation, and about 12000 during the biennial shut down of the reactor. To enhance the sample preparation and counting performance, minimize the entry errors and reduce the processing time, barcode based label generation system was developed for the internal dose monitoring. This paper discusses about the use of barcode system in the internal dose monitoring at TAPS 3 and 4. (author)
2008-11-19
Energy Technology Data Exchange (ETDEWEB)
Leafy samples often used as medicine in the Indian Ayurvedic system and vegetables were analyzed for 20 elements (As, Ba, Br, Ca, Ce, Cr, Cs, Co, Eu, Fe, K, La, Na, Rb, Sb, Sc, Sm, Sr, Th, Zn) by employing Instrumental Neutron Activation Analysis (INAA). The samples were irradiated at the 100 kW TRIGA-MAINZ nuclear reactor and the induced activities were counted by gamma ray spectrometry using an efficiency calibrated high resolution High Purity Germanium (HPGe) detector. The concentration of the elements in the medicinal and vegetable leaves and their biological effects on human beings are discussed.
1999-05-01
Determination of Proper Peaking Time for Ultra Lege detector at Medium Energies
International Nuclear Information System (INIS)
Reducing count losses and pile-up pulse effects in quantitative and qualitative analysis is necessary for accuracy of analysis. Therefore, the optimum peaking time for particular detector systems is important. For this purpose, pure Se and Zn elements were excited by 59.5 keV ?-rays from a 50 mCi 241Am annular radioactive source in this study. The characteristic x-rays emitted from pure Se and Zn elements were detected by using an ultra low energy Ge (Ultra-LEGe) detector connecting Tennelec TC 244 spectroscopy amplifier at different peaking time modes. Overall pulse widths were determined by HM 203-7 oscilloscope connecting amplifier. The proper peaking time for ultra low energy germanium detector (Ultra-LEGe) is determined about 4 ?s.
2008-08-25
Decay of very neutron-rich Mn nuclides and vanishing of the N=40 subshell closure in {sup 66}Fe
The use of chemically selective laser ionization combined with beta-delayed neutron counting at ISOLDE has permitted identification and half-life measurements for {sup 61}Mn up through {sup 69}Mn. The 14(4)-ms half life for {sup 69}Mn is one of the shortest determined for any nuclide beyond the sd shell. Gamma-ray singles and coincidence spectra have been determined for the decays of {sup 64,66}Mn to levels of {sup 64,66}Fe, revealing strong deformation and vanishing of the N=40 subshell in the Fe isotopes. {copyright} {ital 1998 American Institute of Physics.}
1998-12-01
Decay of very neutron-rich Mn nuclides and vanishing of the N=40 subshell closure in "6"6Fe
International Nuclear Information System (INIS)
The use of chemically selective laser ionization combined with beta-delayed neutron counting at ISOLDE has permitted identification and half-life measurements for "6"1Mn up through "6"9Mn. The 14(4)-ms half life for "6"9Mn is one of the shortest determined for any nuclide beyond the sd shell. Gamma-ray singles and coincidence spectra have been determined for the decays of "6"4","6"6Mn to levels of "6"4","6"6Fe, revealing strong deformation and vanishing of the N=40 subshell in the Fe isotopes.
1998-12-21
Decay of Neutron-Rich Mn Nuclides and Deformation of Heavy Fe Isotopes
Energy Technology Data Exchange (ETDEWEB)
The use of chemically selective laser ionization combined with {beta} -delayed neutron counting at CERN/ISOLDE has permitted identification and half-life measurements for 623-ms {sup 61}Mn up through 14-ms {sup 69}Mn . The measured half-lives are found to be significantly longer near N=40 than the values calculated with a quasiparticle random-phase-approximation shell model. Gamma-ray singles and coincidence spectroscopy has been performed for {sup 64,66}Mn decays to levels of {sup 64,66}Fe , revealing a significant drop in the energy of the first 2{sup +} state in these nuclides that suggests an unanticipated increase in collectivity near N=40 . {copyright} {ital 1999} {ital The American Physical Society }
1999-02-01
Decay of Neutron-Rich Mn Nuclides and Deformation of Heavy Fe Isotopes
International Nuclear Information System (INIS)
The use of chemically selective laser ionization combined with #beta# -delayed neutron counting at CERN/ISOLDE has permitted identification and half-life measurements for 623-ms "6"1Mn up through 14-ms "6"9Mn . The measured half-lives are found to be significantly longer near N=40 than the values calculated with a quasiparticle random-phase-approximation shell model. Gamma-ray singles and coincidence spectroscopy has been performed for "6"4","6"6Mn decays to levels of "6"4","6"6Fe , revealing a significant drop in the energy of the first 2"+ state in these nuclides that suggests an unanticipated increase in collectivity near N=40 . copyright 1999 The American Physical Society.
1999-02-01
Conceptualising electronic word of mouth activity: An input-process-output perspective
British Library Electronic Table of Contents (United Kingdom)
Purpose - In light of the growth of internet usage and its important role in the field of e-commerce, electronic word-of-mouth (eWOM) has been changing people's behavior and decisions. People count on other users' opinions and information; they sometimes even make offline decisions based on information acquired online. The purpose of this paper is to conceptualise eWOM activity from an input-process-output (IPO) perspective; propose a classification framework based on the identified academic literature; analyze eWOM literature in terms of quantitative development and qualitative issues that are useful to both academics and researchers; and provide directions and guidelines for future research studies in eWOM. Design/methodology/approach - The authors performed a systematic literature revie...
2011-01-01
Comparison of Galerkin and control volume finite element for advection-diffusion problems.
Energy Technology Data Exchange (ETDEWEB)
The control volume finite element method (CVFEM) was developed to combine the local numerical conservation property of control volume methods with the unstructured grid and generality of finite element methods (FEMs). Most implementations of CVFEM include mass-lumping and upwinding techniques typical of control volume schemes. In this work we compare, via numerical error analysis, CVFEM and FEM utilizing consistent and lumped mass implementations, and stabilized Petrov-Galerkin streamline upwind schemes in the context of advection-diffusion processes. For this type of problem, we find no apparent advantage to the local numerical conservation aspect of CVFEM as compared to FEM. The stabilized schemes improve accuracy and degree of positivity on coarse grids, and also reduce iteration counts for advection-dominated problems.
2005-03-01
Chiral perturbation theory calculation for pn {yields}d{pi} {pi} at Threshold
Energy Technology Data Exchange (ETDEWEB)
We investigate the reaction pn {yields}d{pi} {pi} in the framework of Chiral Perturbation Theory (ChPT). For the first time a complete calculation of the leading-order contributions is presented. We identify various diagrams that are of equal importance as compared to those recognized in earlier works. The diagrams at leading order behave as expected by the power counting. Also for the first time the nucleon-nucleon interaction in the initial, intermediate and final state is included consistently and found to be very important. Although the perturbative series for the production operator is expected to converge very slowly, this study provides the theoretical basis for a future evaluation of the non-resonant contributions in two-pion production reactions in nucleon-nucleon collisions. (orig.)
2011-01-15
Chemical and microbial properties of mahyaveh, a traditional Iranian fish sauce
British Library Electronic Table of Contents (United Kingdom)
To the best of our knowledge, this is the first report on the chemical and microbial properties of traditional Iranian fish sauce, mahyaveh. Fish sauce samples used in this study originated from five different locations in the Southern part of Iran. The pH of mahyaveh samples from different locations was in the range of 4.89-7.55 and NaCl concentration was in the range of 7.48-17.1%. The overall mean of TVB-N in all the samples tested was 3098 mg/kg. Histamine, with the overall mean of 2662 mg/kg, was found to be the main biogenic amine in the Iranian fish sauce. The high histamine content can be related to the high levels of bacterial count especially enterobacteriaceae (overall mean of 3.41 log cfu/g) and lactic acid bacteria (overall mean of 4.13 log cfu/g) in this product. Spermidine w...
2012-01-01
Body-and-cad Geometric Constraint Systems
Motivated by constraint-based CAD software, we develop the foundation for the rigidity theory of a very general model: the body-and-cad structure, composed of rigid bodies in 3D constrained by pairwise coincidence, angular and distance constraints. We identify 21 relevant geometric constraints and develop the corresponding infinitesimal rigidity theory for these structures. The classical body-and-bar rigidity model can be viewed as a body-and-cad structure that uses only one constraint from this new class. As a consequence, we identify a new, necessary, but not sufficient, counting condition for minimal rigidity of body-and-cad structures: nested sparsity. This is a slight generalization of the well-known sparsity condition of Maxwell.
2010-01-01
Biological and morphological characterization of human neonatal fibroblast cell culture B-HNF-1
British Library Electronic Table of Contents (United Kingdom)
In the present study, human neonatal fibroblasts were isolated from a two-month-old human male. The purpose of the present investigation was the analysis of the morphology (light and transmission electron microscopy), karyotype and growth characteristics of the human neonatal fibroblast cell culture B-HNF-1. Moreover, STR typing and mitochondrial DNA amplification and sequencing was also performed. Analysis of chromosomes count showed that B-HNF-1 cell culture is diploid and has normal male karyotype 46, XY, which was stable during cultivation. The transmission electron microscopy demonstrated the ultra-structure of the B-HNF-1 cells; they have typical morphological features of proteosynthesis-active cells. Large number of fibroblasts bearing different shapes and surface characteristics ad...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
Specific parts of several plants (fruits, leaves, stem, bark and roots) often used as medicines in the Indian Ayurvedic system have been analysed for 20 elements (As, Ba, Br, Ca, Cl, Co, Cr, Cu, Fe, K, Mn, Mo, Na, P, Rb, Sb, Sc, Se, Sr and Zn) by employing instrumental neutron activation analysis (INAA). The samples were irradiated with thermal neutrons in a nuclear reactor and the induced activity was counted using high resolution gamma ray spectrometry. Most of the medicinal herbs have been found to be rich in one or more of the elements under study. (Author).
1997-01-01
International Nuclear Information System (INIS)
Nuclear forensic science has become increasingly important for global nuclear security. However, many current laboratory analysis techniques are based on methods developed without the imperative for timely analysis that underlies the post-detonation forensics mission requirements. Current analysis of actinides, fission products, and fuel-specific materials requires time-consuming chemical separation coupled with nuclear counting or mass spectrometry. High-temperature gas-phase separations have been used in the past for the rapid separation of newly created elements/isotopes and as a basis for chemical classification of that element. We are assessing the utility of this method for rapid separation in the gas-phase to accelerate the separations of radioisotopes germane to post-detonation nuclear forensic investigations. The existing state of the art for thermo chromatographic separations, and its applicability to nuclear forensics, will be reviewed. (author)
2011-07-01
Energy Technology Data Exchange (ETDEWEB)
The aim of this study is to develop the methodology which enables to identify the mechanical properties of element such as stress intensity factor by using the AE parameters. Considering the multivariate and nonlinear properties of AE parameters such as ringdown count, rise time, energy, event duration and peak amplitude from fatigue cracks of machine element the principal component regression(PCR) and artificial neural network(ANN) models for the estimation of stress intensity factor were developed and validated. The AE parameters were found to be very significant to estimate the stress intensity factor. Since the statistical values including correlation coefficients, standard mr of calibration, standard error of prediction and bias were stable, the PCR and ANN models for stress intensity factor were very robust. The performance of ANN model for unknown data of stress intensity factor was better than that of PCR model
2001-02-15
Accelerator mass spectrometry: state of the art
Energy Technology Data Exchange (ETDEWEB)
Accelerator Mass Spectrometry (AMS) is the analytical technique of choice for the detection of long-lived radionuclides which cannot be practically analysed with decay counting or conventional mass spectrometry. The main use of AMS has been in the analysis of radiocarbon and other cosmogenic radionuclides for archaeological, geological and environmental applications. In addition, AMS has been recently applied in biomedicine to study exposure of human tissues to chemicals and biomolecules at attomole levels. There is also a world-wide effort to analyse rare nuclides of heavier masses, such as long-lived actinides, with important applications in safeguards and nuclear waste disposal. The use of AMS is limited by the expensive accelerator technology required and there are several attempts to develop smaller and cheaper AMS spectrometers. 5 refs.
1996-12-31
British Library Electronic Table of Contents (United Kingdom)
An exposure chamber is described for the quantifiable addition of fine and ultrafine aerosol particulate matter directly to cells and used to demonstrate the in vitro cytotoxicity of fine 1,4-naphthoquinone particles to murine lung epithelial cells. The electrostatic particulate dosage and exposure system (EPDExS) operates on the principle of electrostatic precipitation and is shown to deposit fine and ultrafine aerosol particles directly to cells with 100% efficiency for particle diameters in the range of 40-530nm. This range is not limited by the EPDExS, but rather by the aerosolization method used for this study. Numbers of particles deposited onto the cells are counted with a condensation particle counter, negating any need to calculate or estimate particle exposure. The process of par...
2008-01-01
A Logic Programming Framework for Combinational Circuit Synthesis
Logic Programming languages and combinational circuit synthesis tools share a common "combinatorial search over logic formulae" background. This paper attempts to reconnect the two fields with a fresh look at Prolog encodings for the combinatorial objects involved in circuit synthesis. While benefiting from Prolog's fast unification algorithm and built-in backtracking mechanism, efficiency of our search algorithm is ensured by using parallel bitstring operations together with logic variable equality propagation, as a mapping mechanism from primary inputs to the leaves of candidate Leaf-DAGs implementing a combinational circuit specification. After an exhaustive expressiveness comparison of various minimal libraries, a surprising first-runner, Strict Boolean Inequality "<" together with constant function "1" also turns out to have small transistor-count implementations, competitive to NAND-only or NOR-only libraries. As a practical outcome, a more realistic ...
2008-01-01
VUV efficiency and radiant emittance characterization of xenon positive column discharges
Energy Technology Data Exchange (ETDEWEB)
The pure xenon dc positive column discharge has been characterized for various xenon pressures, currents, and discharge tube radii. The absolute output at the 147 nm resonance transition has been measured using two independent techniques to yield the radiant emittance at 147 nm (power per unit surface area). The efficiency of 147 nm production is obtained by combining the measured radiant emittance with the measured electrical power per unit length deposited in the gas. The radiant emittance and the efficiency are the two principle figures of merit for characterizing the discharge as a source of VUV radiation. It is observed that the trends in efficiency and radiant emittance change substantially when the discharge transitions from two-step electron impact excitation/ionization at higher pressures to single-step electron impact ionization at lower pressures. Modeling of the xenon positive column discharge yields radiant emittance and efficiency predictions that are ...
1996-12-31
Energy Technology Data Exchange (ETDEWEB)
From long-term real-time radon and radon progeny measurements taken in a relatively large retail store, cyclical patterns were evident, which were found to relate to the overriding influence of the timed air-conditioning system. Concentration of radon, radon progeny and the variability of F factor were found to depend significantly on the intermittent operation of this ventilation-air-conditioning system. After pressure equalisation remedial measures proved ineffective, the air-movement system was utilised to reduce the levels of radon and radon progeny to well within established norms applicable during working hours. It is demonstrated that the average levels for radon and radon progeny are reduced in absolute terms. This amounted to less than 12% of the general level, during designated work periods. Where air movement systems are already installed, as well as other circumstances, their regulation provides an economical solution to meeting legal and other ...
2000-07-01
Energy Technology Data Exchange (ETDEWEB)
Prompt fission neutron spectrum measurements at the University of Massachusetts Lowell 5.5 MV Van de Graaff accelerator laboratory require that the neutron detector efficiency be well known over a neutron energy range of 100 keV to 20 MeV. The efficiency of the detector, has been determined for energies greater than 5.0 MeV using the Weapons Neutron Research (WNR) white neutron source at the Los Alamos Meson Physics Facility (LAMPF) in a pulsed beam, time-of-flight (TOF) experiment. Carbon matched polyethylene and graphite scatterers were used to obtain a hydrogen spectrum. The detector efficiency was determined using the well known H(n,n) scattering cross section. Results are compared to the detector efficiency calculation program SCINFUL available from the Radiation Shielding Information Center at Oak Ridge National Laboratory.
1994-06-01
Homogeneity for highly asymmetric fields has been studied for a Siemens PRIMUS linear accelerator. The flattening filter has a radius smaller than the primary collimator one, creating inhomogeneities that affect large fields in areas far from the collimator axis, and asymmetric fields with large offset. Profiles and absolute dose have been measured in fields with two jaws at maximal position (20 cm) and the other two at maximal overtravel (10 cm.), corresponding to 10 x 10 fields with extreme offset. Profiles have a remarkable gradient decreasing towards the beam edge, making these fields unsuitable for treatments. Results show that the design of the primary collimator and flattening filter assembly has direct consequences in homogeneity. This can have clinical consequences for treatments involving fields that include these inhomogeneous areas. Comparisons with the treatment planning system (Philips Pinnacle) calculations, that computes under the hypotheses of a ...
2005-01-01
The Eddy Experiment: accurate GNSS-R ocean altimetry from low altitude aircraft
During the Eddy Experiment, two synchronous GPS receivers were flown at 1 km altitude to collect L1 signals and their reflections from the sea surface for assessment of altimetric precision and accuracy. Wind speed (U10) was around 10 m/s, and SWH up to 2 m. A geophysical parametric waveform model was used for retracking and estimation of the lapse between the direct and reflected signals with a 1-second precision of 3 m. The lapse was used to estimate the SSH along the track using a differential model. The RMS error of the 20 km averaged GNSS-R absolute altimetric solution with respect to Jason-1 SSH and a GPS buoy measurement was of 10 cm, with a 2 cm mean difference. Multipath and retracking parameter sensitivity due to the low altitude are suspected to have degraded accuracy. This result provides an important milestone on the road to a GNSS-R mesoscale altimetry space mission.
2004-01-01
Synchrotron Self-Compton Analysis of TeV X-ray Selected BL Lacertae Objects
We introduce a methodology for analysis of multiwavelength data from X-ray selected BL Lac (XBL) objects detected in the TeV regime. By assuming that the radio--through--X-ray flux from XBLs is nonthermal synchrotron radiation emitted by isotropically-distributed electrons in the randomly oriented magnetic field of a relativistic blazar jet, we obtain the electron spectrum. This spectrum is then used to deduce the synchrotron self-Compton (SSC) spectrum as a function of the Doppler factor, magnetic field, and variability timescale. The variability timescale is used to infer the comoving blob radius from light travel-time arguments, leaving only two parameters. With this approach, we accurately simulate the synchrotron and SSC spectrum of flaring XBLs in the Thomson through Klein-Nishina regimes. Photoabsorption by interactions with internal jet radiation and the intergalactic background light (IBL) is included. Doppler factors, magnetic fields, and absolute jet ...
2008-01-01
Spherically bent crystal spectroscopy in laser-produced plasma
International Nuclear Information System (INIS)
A curved crystal X-ray spectrographs of reflection type spherical geometry was required based on the Johann scheme. Due to their high efficiency and resolution, X-ray spectrographs of focusing spectrograph spatial resolution are suitable for detecting weak X-ray spectra in spectrometers for laser fusion research. Spherically bent mica crystal with a radius of curvature of 380 mm was used in the spectrometer. The Bragg angle of the crystal analyzer was 51 degree. The image plate was employed to obtain high spatial resolution and a narrow spectral band width, with an effective area of 30 mm x 80 mm. The designed optical path of the X-ray spectrometer beam was 980 mm long from the source to the crystal and the detector. The first experiment was carried out at the 20 J energy laser facility of Research Center of Laser Fusion, China Academy of Engineering Physics. X-ray spectra in an absolute intensity scale were obtained from Al laser-produced plasmas created by laser ...
2008-02-01
Somatic and genetic effects of small doses of ionizing radiations in man
International Nuclear Information System (INIS)
Estimations on the somatic and genetic effects of small doses of ionizing radiations in Man have been proposed by the Advisory Committee on the Biological Effects of Ionizing Radiation, set up by the U.S. National Academy of Sciences. They have been published in an important report, issued in 1972, from which we briefly analyze here the Chapter dealing with the somatic effects. Small doses of raditions are expected to promote only carcinogenic effects. After a rapid survey of the human experience on which the estimations are based, as regards the latent period of cancers, the plateau region (period of high risk) and the absolute and relative risk expressed per rem, per 10"6 persons, per year, for leukaemia (having the highest risk) and for the ''other cancers''. These estimations were obtained by linear extrapolation to the 1 rem level from observations made after irradiation at relatively high dose levels and much higher dose-rates. This extrapolation procedure, ...
1976-01-01
Semiconductor properties and protective role of passive films of iron base alloys
Energy Technology Data Exchange (ETDEWEB)
Semiconductor properties of passive films formed on the Fe-18Cr alloy in a borate buffer solution (pH = 8.4) and 0.1 M H{sub 2}SO{sub 4} solution were examined using a photoelectrochemical spectroscopy and an electrochemical impedance spectroscopy. Photo current reveals two photo action spectra that derived from outer hydroxide and inner oxide layers. A typical n-type semiconductor behaviour is observed by both photo current and impedance for the passive films formed in the borate buffer solution. On the other hand, a negative photo current generated, the absolute value of which decreased as applied potential increased in the sulfuric acid solution. This indicates that the passive film behaves as a p-type semiconductor. However, Mott-Schottky plot revealed the typical n-type semiconductor property. It is concluded that the passive film on the Fe-18Cr alloy formed in the borate buffer solution is composed of both n-type outer hydroxide and inner oxide layers. On the ...
2007-01-15
Semiconductor properties and protective role of passive films of iron base alloys
International Nuclear Information System (INIS)
Semiconductor properties of passive films formed on the Fe-18Cr alloy in a borate buffer solution (pH = 8.4) and 0.1 M H_2SO_4 solution were examined using a photoelectrochemical spectroscopy and an electrochemical impedance spectroscopy. Photo current reveals two photo action spectra that derived from outer hydroxide and inner oxide layers. A typical n-type semiconductor behaviour is observed by both photo current and impedance for the passive films formed in the borate buffer solution. On the other hand, a negative photo current generated, the absolute value of which decreased as applied potential increased in the sulfuric acid solution. This indicates that the passive film behaves as a p-type semiconductor. However, Mott-Schottky plot revealed the typical n-type semiconductor property. It is concluded that the passive film on the Fe-18Cr alloy formed in the borate buffer solution is composed of both n-type outer hydroxide and inner oxide layers. On the other ...
2007-01-01
Rotation seismic sensor and its calibration; Kaiten seibun jishinkei no shisaku to kando no kentei
Energy Technology Data Exchange (ETDEWEB)
Sensor has been developed for the measurement of seismic wave rotary components. The vertical axis rotary component sensor is constituted of four L22Ds, similar to each other in performance, fixed in a ring formation on a metal bed. The ring is 22cm in diameter, and the four coils are connected so that their outputs will be added up. A horizontal axis rotary component sensor is built in the similar way. The rotary component sensors are all connected to a spectrum analyzer for the measurement of micromotions. It is found that the four-L22D combination can detect a rotary component of 335mV/deg/s. The sensor can detect both vertical and horizontal components with roughly the same sensitivity. A ring-form combination of conventional electromagnetic seismometers, though only as a temporary expedient, can perform high-resolution detection of rotary components and determine the absolute values of earthquakes or noise levels. In the case of a gyrosensor available on the ...
1997-05-27
Review and Understanding of Screen-Printed Contacts and Selective-Emitter Formation: Preprint
Energy Technology Data Exchange (ETDEWEB)
A comparison of the loss mechanisms in screen-printed solar cells relative to buried contact cells and cells with photolithography-defined contacts is presented in this paper. Model calculations show that emitter recombination accounts for about 0.5% absolute efficiency loss in conventional screen-printed cells with low-sheet-resistance emitters. Ohmic contact to high-sheet-resistance emitters by screen-printing has been investigated to regain this efficiency loss. Our work shows that good quality ohmic contacts to high sheet-resistance emitters can be achieved if the glass frit chemistry and Ag particle size are carefully tailored. The melting characteristics of the glass frit determine the firing scheme suitable for low contact resistance and high fill factors. In addition, small to regular Ag particles were found to help achieve a higher open-circuit voltage and maintain a low contact resistance. This work has resulted in cells with high fill factors (0.782) on ...
2004-08-01
This paper presents new images and spectroscopy of NGC 34 (Mrk 938) obtained with the du Pont 2.5-m and Baade 6.5-m telescopes at Las Campanas, plus photometry of an HST archival V image. This Mv = -21.6 galaxy has often been classified as a Seyfert 2, yet recently published infrared spectra suggest a dominant central starburst. We find that the galaxy features a single nucleus, a main spheroid containing a blue central disk, and tidal tails indicative of two former disk galaxies. These galaxies appear to have completed merging. The remnant shows three clear optical signs that the merger was gas-rich ("wet") and accompanied by a starburst: (1) It sports a rich system of young star clusters, of which 87 have absolute magnitudes -10.0 > Mv > -15.4. Five clusters with available spectra have ages in the range 0.1-1.0 Gyr, photometric masses between 2x10^6 and 2x10^7 Msun, and are gravitationally bound young globulars. (2) The blue central disk appears to be ...
2007-01-01
Quality Management for Neutron Transmutation Doping of Silicon Ingot in HANARO
Energy Technology Data Exchange (ETDEWEB)
By using this doping method, silicon semiconductors with extremely uniform dopant distributions can be produced, and this is the dominant advantage of NTD compared with a conventional chemical doping. Good uniformity of a dopant concentration is usually required for high power applications such as thyristor (SCR), IGBT, IGCT and GTO and for special sensors. Achieving an accurate neutron fluence corresponding to a target resistivity as well as a uniform irradiation is the prime target of a neutron irradiation for NTD. Generally, in order to reach an accurate neutron fluence, a real time neutron flux is monitored by a neutron detector such as a Self-powered Neutron Detector(SPND). And, after an irradiation, the total irradiation fluence is confirmed by measuring the absolute activity of a neutron activation sample that has been irradiated with a silicon ingot, and thus the SPND can be properly calibrated. Excellent irradiation uniformity and a high accuracy for a ...
2007-10-15
Prestack wave equation reverse-time migration of VSP data
Energy Technology Data Exchange (ETDEWEB)
Based on the wave equation theory, the authors use finite difference method to derive wave-field extrapolation formula, by which both wavefield modeling and migration can be made. The migration program VSP MIG that was developed using P-wave equation may be used to migrate both surface seismic data and VSP data. Besides, it may be applied to the migrations of P-wave data and P-SV wave data, in which case the original velocity model should be modified properly. The migrated image times for P-wave and P-SV wave respectively are absolutely equal. The migrations of upgoing P-wave and upgoing P-SV wave which have been separated can offer migrated P-wave section and migrated S-wave section. Thus, one can get more information than from simultaneous migration of P-wave and S-wave data.
1989-01-01
International Nuclear Information System (INIS)
Samples of air-dust-concentration- and air-dust-deposit measurements were digested by a standardized wet digestion procedure and the amounts of substances in the dust according to class I TA Luft by Atomic Emission Spectroscopy with Inductively Coupled Plasma (AES-ICP). The characteristic values for procedures according to VDI 2449, sheet 1, were determined for lead, vanadium, cadmium, chromium, copper, nickel and zinc. By partial automatic control of the digestion procedure the personel expenditure of work could be reduced by a factor 13. Dust filter samples were analysed without sample preparation by evaporating the material with a solid state laser. The absolute detection limit was between 1 and 100 ng/cm"2 for the elements arsenic, cadmium, cobalt, chromium, mercury, antimony, selen and thallium. For sampling by means of the Beta-Staubmeter the relative detection limits for the laser-ICP were 10-fold lower than by use of a nebulizer. (orig.).
The performance of jet fuel with an oxidant mixture containing 70 percent liquid fluorine and 30 percent liquid oxygen by weight was investigated in a 500-pound-thrust engine operating at a chamber pressure of 300 pounds per square inch absolute. A one-oxidant-on-one-fuel skewed-hole impinging-jet injector was evaluated in a chamber of characteristic length equal to 50 inches. A maximum experimental specific impulse of 268 pound-seconds per pound was obtained at 25 percent fuel, which corresponds to 96 percent of the maximum theoretical specific impulse based on frozen composition expansion. The maximum characteristic velocity obtained was 6050 feet per second at 23 percent fuel, or 94 percent of the theoretical maximum. The average thrust coefficient was 1.38 for the 500-pound thrust combustion-chamber nozzle used, which was 99 percent of the theoretical (frozen) maximum. Mixtures of fluorine and oxygen were found to be self-igniting with jet fuel with fluorine ...
1954-01-01
Energy Technology Data Exchange (ETDEWEB)
The suitability of the turbulent combustion flamelets model in order to predict the index of NO{sub x} production in turbulent flames of hydrogen diffusion is analyzed. In the flamelet approach, the turbulent flame is equivalent to a group of laminar flames submitted to a mechanical stretching which generates a chemical disequilibrium. This effect can be described by the stretching or by the scalar dissipation ratio. A numerical modeling is performed in order to evaluate the advantages of both approaches and to compare the behaviour of the NO{sub x} emission index with the experiments of Chen and Driscoll. This study shows that predictions of NO{sub x} emission indexes have a correct behaviour with respect to the Damkoehler number only when the scalar dissipation ratio is used as a parameter to describe the chemical state outside equilibrium. Predictions of the flamelet models are improving when the Damkoehler number increases. On the other hand, the absolute ...
1996-12-31
Prediction of refrigerant void fraction in horizontal tubes using probabilistic flow regime maps
Energy Technology Data Exchange (ETDEWEB)
A state of the art review of two-phase void fraction models in smooth horizontal tubes is provided and a probabilistic two-phase flow regime map void fraction model is developed for refrigerants under condensation, adiabatic, and evaporation conditions in smooth, horizontal tubes. Time fraction information from a generalized probabilistic two-phase flow map is used to provide a physically based weighting of void fraction models for different flow regimes. The present model and void fraction models in the literature are compared to data from multiple sources including R11, R12, R134a, R22, R410A refrigerants, 4.26-9.58 mm diameter tubes, mass fluxes from 70 to 900 kg/m{sup 2} s, and a full quality range. The present model has a mean absolute deviation of 3.5% when compared to the collected database. (author)
2008-04-15
Energy Technology Data Exchange (ETDEWEB)
Critical properties of a fluid or fluid mixtures are important for describing fluid phase behavior, predicting physical properties, developing equations of state, and designing supercritical-fluid extraction processes, and compression and refrigeration units. The predictive capability of the Peng-Robinson-Styjek-Vera (PRSV-2) equation of state (1986) for critical properties of binary mixtures was investigated. The procedure adopted by Heidemann and Khalil (1980) and discussed by Abu-Eishah et al. (1998) was followed. An optimized value for the binary interaction parameter based on minimization of error between experimental and predicted critical temperatures was used. The standard and the average of the absolute relative deviations in critical properties are included. The predicted critical temperature and pressure for several nonpolar and polar systems agree well with experimental data and are always better than those predicted by the group-contribution method. A ...
1999-09-01
Precise determination of H recoil cross sections for 1.5-3.0 MeV He ions
International Nuclear Information System (INIS)
The differential recoil cross sections of H have been determined for 1.5-3.0 MeV He"+ incidence. In order to obtain precise data, we have performed simultaneous detection and spectrum simulation of recoiled H and backscattered He. In addition, a careful cross check has been made by secondary ion mass spectrometry (SIMS). The present results have revealed a pronounced contribution from a nuclear short-range interaction. The He"+ energy and recoil angle dependence of the H recoil cross sections are well reproduced by adding the nuclear term, which is simply derived from effective range theory. Our computer simulation program of elastic recoil combined with Rutherford backscattering spectra makes it possible to determine the depth distributions of H together with other elements absolutely, without any ambiguities. The present elastic recoil analysis is employed to determine the H composition of amorphous Si(H) films deposited on Si wafers. An excellent agreement, ...
PROPERTIES OF DISKS AND BULGES OF SPIRAL AND LENTICULAR GALAXIES IN THE SLOAN DIGITAL SKY SURVEY
International Nuclear Information System (INIS)
A bulge-disk decomposition is made for 737 spiral and lenticular galaxies drawn from a Sloan Digital Sky Survey galaxy sample for which morphological types are estimated. We carry out the bulge-disk decomposition using the growth curve fitting method. It is found that bulge properties, effective radius, effective surface brightness, and also absolute magnitude, change systematically with the morphological sequence; from early to late types, the size becomes somewhat larger, and surface brightness and luminosity fainter. In contrast, disks are nearly universal, their properties remaining similar among disk galaxies irrespective of detailed morphologies from S0 to Sc. While these tendencies were often discussed in previous studies, the present study confirms them based on a large homogeneous magnitude-limited field galaxy sample with morphological types estimated. The systematic change of bulge-to-total luminosity ratio, B/T, along the morphological sequence is ...
2009-11-01
Motion analysis of parallelly connected FPSO unit and LNG carrier
Energy Technology Data Exchange (ETDEWEB)
Nowadays, the floating production, storage, and offloading (FPSO) units are used to marginal oil fields and deep seas, because of mobility and reduced lead time from discovery to first production. One of the methods for offloading is to moor a tanker alongside the FPSO unit. In this case motion response of the system becomes highly complex, and will be affected by many factors such as hydrodynamic interaction and mechanical connections between the vessels. In this study, a quite general method is developed which has taken into account the hydrodynamic interaction as well as the effects of connectors and mooring lines, in motion response analysis of a multi-body floating system. For this purpose, 3-D source distribution method is applied for hydrodynamic analysis, and linear stiffness matrices are introduced to represent the effect of connectors and mooring lines on the motion equations. The method has been used for motion analysis of a practical problem in which an LNG carrier is ...
1996-12-31
Energy Technology Data Exchange (ETDEWEB)
The use of electricity is indispensable to modern life. As Macao Special Administrative Region becomes a gaming and tourism center in Asia, modeling the consumption of electricity is critical to Macao's economic development. The purposes of this paper are to conduct an extensive literature review on modeling of electricity consumption, and to identify key climatic, demographic, economic and/or industrial factors that may affect the electricity consumption of a country/city. It was identified that the five factors, namely temperature, population, the number of tourists, hotel room occupancy and days per month, could be used to characterize Macao's monthly electricity consumption. Three selected approaches including multiple regression, artificial neural network (ANN) and wavelet ANN were used to derive mathematical models of the electricity consumption. The accuracy of these models was assessed by using the mean squared error (MSE), the mean squared percentage error ...
2008-05-15
Measurement of gamma-ray detection efficiency in irradiated materials examination facility
Energy Technology Data Exchange (ETDEWEB)
The detection efficiency of gamma scanning system in irradiated materials examination facility has been measured. Gamma-ray sources used in this experiment are Cs-Co standard sources a PWR spent fuel rod in which {sup 134}Cs and {sup 154}Eu peaks are clearly identified in the energy region of 500 to 1,600 keV. The distance between source and detector is about 1.6 m. A slit type collimator with 3 mm-width window and 30 mm-thick lead block are installed between source and detector. The detector is a HPGe detector. This equipment is mainly used in gamma scanning of irradiated nuclear fuel. The measured detection efficiency seems to be 1.89 x 10{sup -6} % for 1 MeV gamma-ray. With these results the activities of unknown sources could be measured. This results are expected to be used in the measurement of the absolute distribution of gamma emitting nuclides in nuclear fuel.
2001-05-01
Mass Production of 64Cu with 64Ni(p,n)64Cu Nuclear Reaction and Target Material Recycling
International Nuclear Information System (INIS)
64Cu (T1/2=12.7h, ?- decay: 40%, ?+ decay: 19%, E.C. decay: 41%) is one of the most useful radioisotope in the nuclear medicine due to its multiple decay mode and the intermediate half-life. Several nuclear reaction, i.e., 64Ni(p,n)64Cu, 68Zn(p,?n)64Cu and 64Ni(d,2n)64Cu have been investigated for production. The highest could be obtained with proton irradiation on the enriched 64Ni target. For mass and routine production, the 64Ni target fabrication using electroplating, the reliable chemical separation of 64Cu from the irradiated 64Ni target and the effective recovery process for the recycling of very expensive enriched material ($20,000/g) and so forth are absolutely necessary to be established. In this work, we report our mass production method of 64Cu with 64Ni and Cyclone-30 accelerator
2009-05-01
Energy Technology Data Exchange (ETDEWEB)
The research and development for the first year of the project are performed through specialization of researchers, information from aborad and international cooperation, securement of advanced nuclear technology, development and installation of test equipment, application of external man-power, establishment of advanced test techniques, and certified test method. 1. Absolute efficiency measurement examination technology development of gamma scanning system 2. Sample preparation technology development of SEM and EPMA for micro-structural observation and chemical composition analysis 3. Irradiated high burn-up nuclear fuel transportation and test for PWR 4. Development of hot cell examination techniques and equipment 5. Acquirement of KOLAS system. In addition to the project, the following activities are carried out as follows; - PIE of Hanaro fuel(KH99H-001) - PIE of U-Mo advanced nuclear fuel irradiated at Hanaro - PIE of Hi-MET advanced nuclear fuel irradiated at ...
2002-12-01
Energy Technology Data Exchange (ETDEWEB)
The volume diffusion of Mo in austenitic CrNiMo(N)-steels was studied using the sandwich method. Accordingly the interdiffusion coefficients of Mo were found to be independent of its concentration for the given steel composition with 12 to 19 wt.% Cr, 12 to 16 wt.% Ni, 0 to 2 wt.% Mo and 0 to 0.27 wt.% N and within the temperature range from 1283 to 1523 K. The diffusivity of Mo is greater than that of Cr, Ni and Fe in such steels. The diffusion parameters of Mo are decreased by alloying addition of nearly 0.25 wt.% N in steel; possibly as a result of lattice expansion or increasing vacancy concentration caused by N. Small variations in Cr and Ni initial contents of examined specimens showed negligible effect on the absolut values of interdiffusion coefficients of Mo. (orig.).
1991-08-01
Improved eddy-current inspection for steam generator tubing
Energy Technology Data Exchange (ETDEWEB)
Computer programs have been written to allow the analysis of different types of eddy-current probes and their performance under different steam generator test conditions. The probe types include the differential bobbin probe, the absolute bobbin probe, the pancake probe and the reflection probe. The generator test conditions include tube supports, copper deposits, magnetite deposits, denting, wastage, pitting, cracking and IGA. These studies are based mostly on computed values, with the limited number of test specimens available used to verify the computed results. The instrument readings were computed for a complete matrix of the different test conditions, and then the test conditions determined as a function of the readings by a least-squares technique. A comparison was made of the errors in fit and instrument drift for the different probe types. The computations of the change in instrument reading due to the defects have led to an inversion'' ...
1989-01-01
High-resolution beta imaging; L'imagerie beta haute resolution
Energy Technology Data Exchange (ETDEWEB)
For many years, {beta} radioactivity has been used to label molecules and follow them in various biological processes. {beta} imaging is obtained by autoradiography. Classically made on films or on photographic emulsions, autoradiography is now supplanted by radio-imagers which are very performing. The phosphor-imager, {beta}-imager and {mu}-imager are the systems mainly used today and their operating principles and properties are compared. The great advantages of these imagers are: their rapidity to obtain results and their reliability for absolute quantification. All emitters ({beta}{sup -}, {beta}{sup -} -{gamma} and {beta}{sup +}) are detectable as well as the gamma emitters of nuclear medicine, by means of their low energy electrons ejected during y emission. Phosphor-imager is well suited to energetic tracers and large series of experiments. Real time radio-imagers ({beta}-imager and {mu}-imager) are preferred to verify experimental conditions. The ...
2007-04-15
Least-squares analyses were performed on a set of atomic masses using standard and generalized senaiempirical mass laws. Presumably because of errors in the assured form of the standand mass law, its least-squares coefficients can be determined at best to an accuracy of about 10%, and masses are predicted with an uncertainty of several Mev/c/sup 2/. The standard mass law was generalized by addition of shell effect and deformation terms. While the least-squares fitting of the generalized mass law is better than for the standard mass law, it is still not possible to predict atomic masses to an accuracy better than a few Mev/c/sup 2/. The nuclear deformations and the well depth . of the nuclear interaction obtained from the additional mass-law terms are in reasonable agreement with more accurate determinations by other methods. A similar statement applies to the nuclear radius constant as obtained from the least-squares coefficient of the Coulomb energy ...
1959-11-15
Equation of state of laser-shocked compressed iron; Equation d'etat du fer comprime par choc laser
Energy Technology Data Exchange (ETDEWEB)
This thesis enters the field of highly compressed materials equation of state studies. In particular, it focuses on the case of laser shock compressed iron. This work indeed aims at getting to the conditions of the earth's core, comprising a solid inner core and a liquid outer core. The understanding of phenomena governing the core's thermodynamics and the geodynamic process requires the knowledge of iron melting line locus around the solid-liquid interface at 3.3 Mbar. Several experiments were performed to that extent. First, an absolute measurement of iron Hugoniot was obtained. Following is a study of partially released states of iron into a window material: lithium fluoride (LiF). This configuration enables direct access to compressed iron optical properties such as reflectivity and self-emission. Interface velocity measurement is dominated by compressed LiF optical properties and is used as a pressure gauge. Using a dual wavelength ...
2004-01-01
International Nuclear Information System (INIS)
For the first time absolute total cross sections for electron-impact excitation of a multiply-charged ion have been measured using an electron-energy-loss technique. Measurements were made near threshold for the process e + Si"3"+(3s"2S_1_/_2) #-># e+Si"3"+(3p"2P_1_/_2_,_3_/_2)-8.88 eV. The 10"-"1"5 cm"2 measured cross section agrees with results of 7-state close coupling calculations to better than the #+-#20% (90% CL) total uncertainty of the measurements. Convoluting the theoretical curve with a Gaussian energy distribution indicates an energy width of 0.15 < or approx. #DELTA#E < or approx. 0.20 eV. (orig.).
Determination of reactivity from power spectral density measurements with /sup 252/Cf. [LMFBR
The theory of a method of determination of reactivity from power spectral density measurements with /sup 252/Cf and the results of experiments with a critical assembly mockup of a liquid-metal fast breeder reactor (LMFBR) and with uranium (93.2 wt % /sup 235/U) metal cylinders and a sphere are presented. This method of reactivity determination has an advantage over existing methods in that it determines the reactivity only from properties of the reactor at the subcritical state of interest and thus does not require a calibration near delayed criticality. In these experiments, the reactivity was varied by changing the fissile loading or the amount of neutron absorber inserted; for the LMFBR mockup, the reactivity varied to approximately 75 dollars subcritical, and for the uranium metal assemblies to approximately 30 dollars subcritical. These experiments verified for the first time the predictions of theory that could be tested in the measurements. This method has potential use in the ...
1978-04-01
Dependence of proton beam polarization on ion source transition configurations
Energy Technology Data Exchange (ETDEWEB)
The polarization of extracted SATURNE II proton beam as a function of different ion source configurations was studied. Two distinct experiments were necessary for this purpose. In the first one, the left-right instrumental asymmetry of the beam polarimeter was determined using an unpolarized beam. In the second one this correction factor was applied to asymmetries measured with the beam from the polarized ion source in all polarization states. The measurements were carried out at the proton beam kinetic energy 0.80 GeV, where the pp-elastic scattering analyzing power is near its maximum. The results confirmed that the two so-called ``unpolarized states`` of the source were polarized to several percent, whereas the absolute values of the beam polarizations in the so-called ``polarized states`` were equal and opposite. It was observed that the hexapole lens of the ion source produced beam polarization in the absence of any transition. The beam polarization as a ...
1997-11-11
International Nuclear Information System (INIS)
A method that employs simultaneous neutron and #gamma#-ray diffraction techniques is proposed for accurate measurements of strains with or without an applied electric field (0-100 kV m"-"1). Instead of an absolute determination of the position of the neutron Bragg peak, a relative measurement of the neutron and #gamma# peak positions is used and allows a determination of the lattice-parameter changes with an accuracy of within 2 x 10"-"6. This technique avoids systematic errors originating in sample rotations by taking advantage of a reference directly related to the crystal lattice. The method appears to be particularly important for crystals that exhibit structural phase transitions, as demonstrated by the measurement of the strain U_x_x in KH_2PO_4 crystals as a function of temperature and applied electric field. In this case the errors would amount to #+-#20%. The results demonstrate the need to re-examine the theory previously proposed by Uesu, Tanaka and ...
1987-12-01
International Nuclear Information System (INIS)
The microstructures of so called high temperature alloys, which have been developed for service temperatures up to 800"0C, are not necessarily stable at higher temperatures. The mobility of alloying elements is very high in FeCrNi alloys at 950 "0C e.g. iron, chromium or nickel can diffuse up to 0.1 mm distance in one year, which is about a grain diameter. Interstitials like carbon or nitrogen show a four orders of magnitude higher diffusivity than the alloying elements. In addition, the carbon solubility in this type of alloy is reported to be very low. Therefore the alloys are supersaturated with carbon after heat treatment above 1100 "0C and water quenching although the absolute carbon content is very low. At service temperatures around 800"0C the solubility of carbon is still about one order of magnitude lower than at heat treatment temperature. This will lead, together with the high mobility of elements, to precipitation of carbides even after short times and ...
1981-05-01
Construction and Calibration of the Laser Alignment System for the CMS Tracker
The CMS detector (Compact Muon Solenoid) is under construction at one of the four proton-proton interaction points of the LHC (Large Hadron Collider) at CERN, the European Organization for Nuclear Research (Geneva, Switzerland). The inner tracking system of the CMS experiment consisting of silicon detectors will have a diameter of 2.4 m and a length of 5.4 m representing the largest silicon tracker ever. About 15000 silicon strip modules create an active silicon area of 200 m2 to detect charged particles from proton collisions. They are placed on a rigid carbon fibre structure, providing stability within the working conditions of a 4 T solenoid magnetic field at ?10oC. Knowledge of the position of the silicon detectors at the level of 100 ?m is needed for an efficient pattern recognition of charged particle tracks. Metrology methods are used to survey tracker subdetectors and the integrated Laser Alignment System (LAS) provides absolute positioning of support ...
2006-01-01
CdS and ZnS quantum dots embedded in hyaluronic acid films
Energy Technology Data Exchange (ETDEWEB)
An in situ synthesis of ZnS and CdS quantum dots (QDs) in an aqueous solution of sodium hyaluronate (Hyal) produced foils emitting light on excitation with a UV light. The wavelength of emission was only slightly QDs size and more QDs concentration dependent and reached up to {approx}320 nm in the case of ZnS and {approx}400-450 nm in the case of CdS. Nanoparticles remained as non-agglomerated 10-20 nm nanoclusters. CdS/Hyal and ZnS/Hyal-QDs biocomposites were characterized using photoluminescence (PL), IR spectrometric techniques, and Transmission Electron Microscopy (TEM). The absolute molecular weights, radii of gyration, R{sub g}, and thermodynamic properties of the obtained foils are given. Electric resistivity studies performed for the hyaluronic foil in the 100-1000 V range have revealed that the hyaluronate foil has very weak conducting properties and QDs only insignificantly affect those properties as QDs practically did not interact with the foil. Size ...
2009-07-29
Can deployment of renewable energy put downward pressure on natural gas prices?
International Nuclear Information System (INIS)
High and volatile natural gas prices have increasingly led to calls for investments in renewable energy. One line of argument is that deployment of these resources may lead to reductions in the demand for and price of natural gas. Many recent US-based modeling studies have demonstrated that this effect could provide significant consumer savings. In this article we evaluate these studies, and benchmark their findings against economic theory, other modeling results, and a limited empirical literature. We find that many uncertainties remain regarding the absolute magnitude of this effect, and that the reduction in natural gas prices may not represent an increase in aggregate economic wealth. Nonetheless, we conclude that many of the studies of the impact of renewable energy on natural gas prices appear to have represented this effect within reason, given current knowledge. These studies specifically suggest that a 1% reduction in US natural gas demand could lead to ...
2007-01-01
Can deployment of renewable energy put downward pressure on natural gas prices?
International Nuclear Information System (INIS)
High and volatile natural gas prices have increasingly led to calls for investments in renewable energy. One line of argument is that deployment of these resources may lead to reductions in the demand for and price of natural gas. Many recent US-based modeling studies have demonstrated that this effect could provide significant consumer savings. In this article we evaluate these studies, and benchmark their findings against economic theory, other modeling results, and a limited empirical literature. We find that many uncertainties remain regarding the absolute magnitude of this effect, and that the reduction in natural gas prices may not represent an increase in aggregate economic wealth. Nonetheless, we conclude that many of the studies of the impact of renewable energy on natural gas prices appear to have represented this effect within reason, given current knowledge. These studies specifically suggest that a 1% reduction in US natural gas demand could lead to ...
2007-01-01
Breakup of 96 MeV #alpha#-particles in the "5"8","6"4Ni niclei fields
International Nuclear Information System (INIS)
The aim of the paper is to investigate the process of #alpha#-particle breakup into two deuterons and to estimate the applicability of data on breakup for extraction of diffusivity parameter (a) in the framework of the diffraction approach. Measurements of absolute values of differential cross sections (DCS) of 96 MeV #alpha#-particle breakup on "5"8","6"4Ni are carried out in the limited angular range: #THETA#_1=22.5 deg, #THETA#_2=50, 55, 60, -50, -60 deg. Wide maxima typical for the process of incident #alpha#-particle breakup are observed in deuteron energy spectra. Measured DCS for #alpha#-particle breakup show distinct difference for "5"8Ni and "6"4Ni. The calculations describe satisfactorily this difference in the framework of the diffraction approach, if it is supposed that the diffusivity parameter for "5"8Ni nucleus has the value a=0.65 fm, and for "6"4Ni - a=0.85 fm.
Binary Pseudo-random Grating Standard for Calibration of Surface Profilometers
Energy Technology Data Exchange (ETDEWEB)
We suggest and describe the use of a binary pseudo-random (BPR) grating as a standard test surface for measurement of the modulation transfer function (MTF) of interferometric microscopes. Knowledge of the MTF of a microscope is absolutely necessary to convert the measured height distribution of a surface undergoing metrology into an accurate power spectral density (PSD) distribution. For an'ideal' microscope with an MTF function independent of spatial frequency out to the Nyquist frequency of the detector array with zero response at higher spatial frequencies, a BPR grating would produce a flat 1D PSD spectrum, independent of spatial frequency. For a'real' instrument, the MTF is found as the square root of the ratio of the PSD spectrum measured with the BPR grating to the'ideal,' spatial frequency independent, PSD spectrum. We present the results from a measurement of the MTF of MicromapTM-570 interferometric ...
2008-01-16
Band parameters for III - V compound semiconductors and their alloys
International Nuclear Information System (INIS)
We present a comprehensive, up-to-date compilation of band parameters for the technologically important III - V zinc blende and wurtzite compound semiconductors: GaAs, GaSb, GaP, GaN, AlAs, AlSb, AlP, AlN, InAs, InSb, InP, and InN, along with their ternary and quaternary alloys. Based on a review of the existing literature, complete and consistent parameter sets are given for all materials. Emphasizing the quantities required for band structure calculations, we tabulate the direct and indirect energy gaps, spin-orbit, and crystal-field splittings, alloy bowing parameters, effective masses for electrons, heavy, light, and split-off holes, Luttinger parameters, interband momentum matrix elements, and deformation potentials, including temperature and alloy-composition dependences where available. Heterostructure band offsets are also given, on an absolute scale that allows any material to be aligned relative to any other. [copyright] 2001 American Institute of ...
2001-06-01
BDTPS The BNCT Treatment Planning System jointly developed at DIMNP and JRC/IE
The idea to couple the Treatment Planning System (TPS) to the information on the real boron distribution in the patient is the main added value of the new methodology set-up at DIMNP of University of Pisa, in collaboration with the JRC of Petten (NL). The methodology has been implemented in the new TPS, called BDTPS (Boron Distribution Treatment Planning System), which takes into account the actual boron distribution in the patient brain, while the standard TPS assumes a uniform boron distribution, absolutely far from the reality. Nowadays, Positron Emission Tomography (PET) is able to provide this in vivo information. The new TPS, based on the Monte Carlo technique, has been validated comparing the main BNCT parameters (thermal flux, boron dose, etc.) as measured during the irradiation of a special heterogeneous boron phantom (HEBOM), ad hoc designed, as calculated by the BDTPS and by the standard TPS SERA. An evident SERA overestimation of the thermal neutron ...
2003-01-01
Assessment of dose-time-effect surfaces for somatic late effects after low dose irradiation
International Nuclear Information System (INIS)
Awaiting new data from RERF, an attempt was made to estimate the somatic risks of low doses of radiation for members of the German public. The new estimate follows closely the approach used in deriving the values published in the NIH Radioepidemiological Tables. The lifetime risk factors thus calculated are significantly larger than the estimates presented in ICRP Report 26 and are consistent with estimates recently made in the ongoing reactor safety study of NUREG. The increase in lifetime risks is mainly due to the introduction of a new time projection model which appears to be more consistent with the epidemiological data for many late effect end points than the constant absolute risk model previously employed. Results from a study in which epidemiological data were stochastically simulated with a computer indicate that the shapes of actual dose effect curves might be significantly more influenced by pure chance than by the dose dependency of underlying ...
1988-04-01
British Library Electronic Table of Contents (United Kingdom)
Structural instability of wild-type fibroblast growth factor (FGF)-1 and its dependence on exogenous heparin for optimal activity diminishes its potential utility as a therapeutic agent. Here we evaluated FGFC, an FGF1:FGF2 chimeric protein, for its receptor affinity, absolute heparin-dependence, stability and potential clinical applicability. Using BaF3 transfectants overexpressing each FGF receptor (FGFR) subtype, we found that, like FGF1, FGFC activates all of the FGFR subtypes (i.e., FGFR1c, FGFR1b, FGFR2c, FGFR2b, FGFR3c, FGFR3b and FGFR4) in the presence of heparin. Moreover, FGFC activates FGFRs even in the absence of heparin. FGFC stimulated keratinocytes proliferation much more strongly than FGF2, as would be expected from its ability to activate FGFR2b. FGFC showed greater struct...
2008-01-01
Energy Technology Data Exchange (ETDEWEB)
New and elaborate techniques for alpha-particle autoradiography of thick specimens based on the plastic nuclear track detector CR-39 have been developed. These permit a full analysis of both trace element and microdistribution of alpha-active nuclides present. The important features of the techniques are: 1) reliable low level configuration down to 10/sup -15/ Ci g/sup -1/, 2) high resolution alpha-particle spectroscopy in CR-39, 3) determination of the absolute abundance of alpha active nuclides present in the specimen, 4) determination of the distribution of emission with height up to 30 microns above the surface of the autoradiograph, 5) the local determination of the radon diffusion coefficient in the specimen which is needed to calculate the activity levels of /sup 222/Rn and daughter nuclei, 6) the analysis of small and large clusters of alpha-particle activity recorded on the autoradiograph. These techniques are briefly discussed.
1984-06-15
Transport and superconducting properties of RNi{sub 2}B{sub 2}C (R=Y, Lu) single crystals
Energy Technology Data Exchange (ETDEWEB)
The in-plane resistivity, in-plane absolute thermopower, and upper critical field measurements are reported for single-crystal samples of YNi{sub 2}B{sub 2}C and LuNi{sub 2}B{sub 2}C superconductors. The in-plane resistivity shows metallic behavior and varies approximately linearly with temperature near room temperature (RT) but shows nearly quadratic behavior in temperature at low temperatures. The YNi{sub 2}B{sub 2}C and LuNi{sub 2}B{sub 2}C single-crystal samples exhibit large transverse magnetoresistance ({approx}6{endash}8{percent} at 45 kOe) in the ab plane. The absolute thermopower S(T) is negative from RT to the superconducting transition temperature T{sub c}. Its magnitude at RT is a few times of the value for a typical good metal. S(T) is approximately linear in temperature between {approx}150 K and RT. Extrapolation to T=0 gives large intercepts (few {mu}V/K) for both samples suggesting the presence of a much larger ...
1997-04-01
International Nuclear Information System (INIS)
The absolute cross sections of "2"3Na(p,n)"2"3Mg, "2"7Al(p,n)"2"7Si and "3"0Si(#alpha#,n)"3"3S reactions were measured in the incident energy range of 5.05 to 5.80, 5.80 to 6.25 and 3.975 to 6.235 MeV respectively using a spherically shaped 4#pi# neutron detector. In the energy range 5.80 to 7.80 and 6.235 to 11.30 MeV the absolute cross sections of "2"3Na(p,n)"2"3Mg and "3"0Si-(#alpha#,n)"3"3S reactions were determined by optical model calculations. The cross sections of the inverse reactions "2"3Mg(n,p)"2"3Na and "3"3S(n,#alpha#)"3"0Si were also calculated by the same method for the neutron energy range of 10 keV to 7.50 MeV for each reaction. The cross section of the latter reaction in the neutron energy range of 10 keV to 840 keV was also determined from its inverse reaction "3"0Si(#alpha#,n)"3"3S by the application of the detailed balance theorem. The reactions for which the cross sections were determined are of importance in stellar ...
Clinical implementation of a convolution based algorithm for 3D treatment planning
International Nuclear Information System (INIS)
Purpose/Objective: With the advent of computed tomography and magnetic resonance imaging, the three dimensional representation of the patient anatomy has become an invaluable resource for better diagnosis and delineation of the target volume and sensitive structures in radiation therapy. Although the therapeutic linear accelerator industry has made available highly sophisticated equipment, the aggressiveness in dose prescription and delivery has to be complimented by accurate dose computation methods. We have adopted a convolution/superposition algorithm for the calculation of absolute dose that fully accounts for the external shape and internal structure of the patient for photon treatment radiotherapy. In this paper, we will discuss the principles of the convolution algorithm and we will show how the computed dose compares to clinically relevant treatment techniques. Materials and Methods: A computer controlled data acquisition system and a water tank where used ...
Basic research on cermet nuclear fuel
Energy Technology Data Exchange (ETDEWEB)
Production of cermet nuclear fuel having fine uranium dioxide (UO{sub 2}) particles dispersed in matrix metal requires basic property data on the compatibility of matrix metal with fission product compounds. It is thermodynamically suggested that, as burnup increases, cesium in oxide fuel reacts with the fuel, other fission products or cladding pipe and produces cesium uranates, cesium molybdate, or cesium chromate in stainless steel cladding pipe. Attempt was made to measure the thermal expansion coefficient and thermal conductivity of cesium uranates (Cs{sub 2}UO{sub 4} and Cs{sub 2}U{sub 2}O{sub 7}), cesium molybdate (Cs{sub 2}MoO{sub 4}) and cesium chromate (Cs{sub 2}CrO{sub 4}). Thermal expansion was measured by X-ray diffraction and determined by Cohen`s method. Thermal conductivity was obtained by measuring thermal diffusion by laser flash method. The thermal expansion of Cs{sub 2}UO{sub 4} and Cs{sub 2}U{sub 2}O{sub 7} is as low as 1.2% for the former and 1.0% for the latter, ...
1998-01-01
Recent studies have shown Y chromosome microdeletions associated with male infertility. The factors responsible for Y chromosome microdeletions in spermatozoa remain unresolved. However, the environmental pollutants are known to damage DNA in differentiating and maturing germ cells in the male reproductive tract. Therefore, the aim of this study was to investigate the effects of seminal hexachlorocyclohexane (HCH) and its isomers, an environmental pollutant, in 50 fertile and 50 infertile males in relation to semen quality and the incidence of Y chromosome microdeletion in azoospermic factor (AZF) region. As compared to control, an increased HCH level and significantly decreased semen quality were observed in the infertile males. A positive significant association was found between sperm count with alpha-HCH and beta-HCH in the infertile males. A negative significant association was observed between sperm counts with gamma-HCH in asthenospermia ...
2010-06-18
Energy Technology Data Exchange (ETDEWEB)
The studies of {sup 137}Cs and {sup 239+240}Pu distributions in surface seawater at South China Sea within the Exclusive Economic Zone (EEZ) of Peninsular Malaysia were carried out in June 2008. The analysis results will serve as additional information to the expanded baseline data for Malaysia's marine environment. Thirty locations from extended study area were identified in the EEZ from which large volumes of surface seawater samples were collected. Different co-precipitation techniques were employed to concentrate cesium and plutonium separately. A known amount of {sup 134}Cs and {sup 242}Pu tracers were used as yield determinant. The precipitate slurry was collected and oven dried at 60 {sup o}C for 1-2 days. Cesium precipitate was fine-ground and counted using gamma-ray spectrometry system at 661.62 keV, while plutonium was separated from other radionuclides using anion exchange, electrodeposited and counted using alpha ...
2010-09-15
Reduced "9"9"mTc labelled NCA-95/CEA-antibody uptake in liver due to gentle antibody reconstitution
International Nuclear Information System (INIS)
The influence of reconstituting a murine monoclonal IgG_1 antibody kit with pertechnetate Tc99m on antibody distribution in the liver, spleen and sternal bone marrow of patients was examined. The "9"9"mTc-labelled antibody used is directed against non-specific cross-reacting antigen (NCA-95) and carcinoembryonic antigen (CEA) and has been successfully applied for imaging tissue inflammation and bone marrow scanning. Radioactivity uptake was determined in the liver, spleen, bone marrow and a precordial background region in a consecutive series of 25 patients, examined with an antibody preparation, routinely radiolabelled according to the manufacturer's recommendations and in 14 patients, in whom the antibody was reconstituted with special care, avoiding bubble formation and dropping of buffer into the antibody-containing vial. Gentle compared with routine antibody reconstitution caused a highly significant reduction of the antibody uptake in the liver, as determined by ...
Radiation therapy for Kasabach-Merritt syndrome. Analysis of unfavorable factors in 5 children
Energy Technology Data Exchange (ETDEWEB)
During the past 10 years, five infants with Kasabach-Merritt syndrome (K-M) receiving radiation therapy were reported. We investigated whether radiation therapy for K-M was useful and what the unfavorable factors of K-M were. During the past 10 years, we have treated five infants with K-M. The syndrome occurred at ages ranging from birth to 4 months. The incidence of female to male ratio was 3:2. Among 5 cases, the site of hemangioma was as follows; shoulder, anterior chest wall, lower abdominal wall, face and neck and inguinal site. All 5 cases received medication to control the coagulopathy including prednisone and blood transfusion at first. Because the platelet count and the bleeding tendency did not improve in any case, these cases received radiation therapy. Total dose ranged from 5 to 10 Gy and fraction-size ranged from 0.5 to 1.75 Gy. Irradiation session was 2 or 3 times per week. In 5 cases, 4 cases showed cure of bleeding tendency and disappearance of ...
1996-03-01
Quality changes of irradiated spices stored in different indigenous packaging materials
International Nuclear Information System (INIS)
The changes in quality of irradiated spices, i.e., nutmeg (Myristica fragrans), black pepper and white pepper (Piper nigrum) stored in different indigenous packaging materials were evaluated. Packaging materials used were tin cans; tin can lined with polypropylene film, tin can lined with wrapping paper, woven polypropylene bag and woven polypropylene bag lined with polypropylene film. Packaging in woven polypropylene bag could cause significant changes in a_w-values and moisture contents of the spices. In the tin can, no significant change was found during storage. By applying a polypropylene film liner inside the plastic bag, the changes could be retarded. The other parameters observed, i.e. total plate count, total mould and yeast count and organoleptic scores of the samples were not significantly affected by the packaging method. A dose of 5 kGy could reduce the microbial load of the spices by about 2-3 log cycles. A significant decrease in ...
1990-03-01
International Nuclear Information System (INIS)
This present study evaluated the effect of gamma radiation on the fungal survival in packed medicinal plants, purchased from wholesale and retail market, in different period (0 and 30 days) after the treatment. Five kind of medicinal plants (Peumus boldus, Camellia sinensis, Maytenus ilicifolia, Paullinia cupana and Cassia angustifolia), were collected from different cities of Sao Paulo State, and submitted to irradiation treatment using a 60Co source (type Gammacell 220) with doses of 5,0 kGy and 10 kGy and at dose rate of 3.0 kGy/h. Non-irradiated samples (control group) were used for fungal counts and serial dilutions from 10-1 to 10-6 of the samples were seeded in duplicates and plated using the surface culture method in Dichloran 18% Glycerol Agar (DG 18) and were counted after five days at 25 deg C. The control group revealed the presence of genera Aspergillus and Penicillium, which are known as toxigenic fungi and a few samples of ...
2006-12-20
Evaluation of femoral neck fracture healing in man by serial sup(99m)Tc-diphosphonate scintimetry
Energy Technology Data Exchange (ETDEWEB)
In this study the distribution of sup(99m)Tc-diphosphonate and tetracycline and histological examination were also investigated in femoral heads obtained during replacement surgery. One hundred patients received scintigraphic examinations immediately after the occurrence of injury and every month thereafter. Ten mCi of sup(99m)Tc-diphosphonate was injected intravenously. Three hours later, detailed scintigrams of the bilateral hip areas were made with a scintillation camera connected to a computer. The uptake of sup(99m)Tc-diphosphonate in the fracture was expressed as a ratio of the counts recorded in one area to those recorded in the other area. A peak value in count ratio was recorded in all patients 4 to 6 weeks after fractures. One hundred patients were classified into a normal healing group and a delayed or non-union group. Namely, sup(99m)Tc-diphosphonate uptake was significantly higher in the delayed or non-union group than in the ...
1981-02-01
Evaluation of femoral neck fracture healing in man by serial sup(99m)Tc-diphosphonate scintimetry
International Nuclear Information System (INIS)
In this study the distribution of sup(99m)Tc-diphosphonate and tetracycline and histological examination were also investigated in femoral heads obtained during replacement surgery. One hundred patients received scintigraphic examinations immediately after the occurrence of injury and every month thereafter. Ten mCi of sup(99m)Tc-diphosphonate was injected intravenously. Three hours later, detailed scintigrams of the bilateral hips areas were made with a scintillation camera connected to a computer. The uptake of sup(99m)Tc-diphosphonate in the fracture was expressed as a ratio of the counts recorded in one area to those recorded in the other area. A peak value in count ratio was recorded in all patients 4 to 6 weeks after fractures. One hundred patients were classified into a normal healing group and a delayed or non-union group. Namely, sup(99m)Tc-diphosphonate uptake was significantly higher in the delayed or non-union group than in the ...
International Nuclear Information System (INIS)
The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 (16N) and Oxygen-19 (19O) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of 19O and 16N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high ambient radiation level even though sensitivity is appreciably good. For detector position in RB in the accessible areas and out side the RE containment, the travel time for the ...
2006-11-13
Calibration curves of a PGNAA system for cement raw material analysis using the MCNP code
Energy Technology Data Exchange (ETDEWEB)
In large samples, the {gamma}-ray count rate of a prompt gamma neutron activation analysis system is a multi-variable function of the elemental dry composition, density, water content and thickness of the material. The experimental calibration curves require tremendous laboratory work, using a great number of standards with well-known compositions. Although a Monte Carlo simulation study does not avoid the experimental calibration work, it reduces the number of experimental calibration standards. This paper is part of a feasibility study for a PGNAA system for on-line continuous characterisation of cement raw material conveyed on a belt (Oliveira, C., Salgado, J. and Carvalho, F. G. (1997) Optimisation of PGNAA instrument design for cement raw materials using the MCNP code. J. Radioanal. Nucl. Chem. 216(2), 191-198; Oliveira, C., Salgado, J., Goncalves, I. F., Carvalho, F. G. and Leitao, F. (1997a) A Monte Carlo study of the influence of geometry arrangements and ...
1998-12-01
International Nuclear Information System (INIS)
The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 ("1"6N) and Oxygen-19 ("1"90) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of "1"9O and "1"6N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high background even though sensitivity is appreciably good. For detector position out side the RB containment, the travel time for the feed water becomes very long resulting ...
2005-11-23
A spatial sensitivity analysis technique for neutron and gamma-ray measurements
International Nuclear Information System (INIS)
In the fields of medical imaging, geophysical well logging, and industrial radiography, it is often of interest to characterize the spatially distributed sensitivities of neutron and gamma-ray measurement devices to the physical properties of the materials being examined. For instance, one may wish to know how the count rate in a detector varies in response to small changes in the local density of the irradiated object as a function of position. Experimental determination of such sensitivity functions is often impractical. Consequently, we have developed a general three-dimensional Monte Carlo numerical technique that allows us to directly compute the differential sensitivity of an arbitrary integral response parameter, such as a time- or energy-discriminated count rate, with respect to the spatial distribution of macroscopic cross sections and sources in the irradiated medium. Sensitivities to object density, porosity, etc., can easily be ...
1992-09-08
Contamination by depleted uranium (Du) in South Serbia
Energy Technology Data Exchange (ETDEWEB)
The paper present the results of the study on D.U. (depleted uranium) contamination in the environment and possible effects on animal healths in the region o f Bujanovac. Samples of soil, feed, leaves, grass, lichen, moss, honey and water were collected randomly in 2003/2004 in the vicinity of the target area (500-1000 m) and 5 km from the target area. Activity of the radionuclides ({sup 226}Ra, {sup 232}Th, {sup 40}K, {sup 210}Pb, {sup 238}U, {sup 235}U, {sup 137}Cs, {sup 7}Be) in soils, grass, lichen, moss and honey was determined on Hp Ge detector (Canberra, relative efficiency 23%) by standard gamma spectrometry. Total alpha and beta activity in water was determined on proportional alpha/beta counter (Canberra 2400, efficiency for alpha emitters 11%, efficiency for beta emitters 30%). Non significantly higher values of concentrations of {sup 226}Ra, {sup 232}Th, {sup 238}U and {sup 235}U were measured in the immediate vicinity of the targeted site, but {sup 235}U/{sup 238}U ...
2006-07-01
Waste sampling and characterization facility (WSCF)
Energy Technology Data Exchange (ETDEWEB)
The Waste Sampling and Characterization Facility (WSCF) complex consists of the main structure (WSCF) and four support structures located in the 600 Area of the Hanford site east of the 200 West area and south of the Hanford Meterology Station. WSCF is to be used for low level sample analysis, less than 2 mRem. The Laboratory features state-of-the-art analytical and low level radiological counting equipment for gaseous, soil, and liquid sample analysis. In particular, this facility is to be used to perform Resource Conservation and Recovery Act (RCRA) of 1976 and Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) of 1980 sample analysis in accordance with U.S. Environmental Protection Agency Protocols, room air and stack monitoring sample analysis, waste water treatment process support, and contractor laboratory quality assurance checks. The samples to be analyzed contain very low concentrations of radioisotopes. The main reason that ...
1994-10-01
Use of a predictor for total body potassium content: application to nutrition and hypertension
International Nuclear Information System (INIS)
Total body potassium (TBK), measured at different institutions, has no reference standard for comparison. A useful reference formula, however, based on body size and age, has been derived at the Brookhaven National Laboratory. This formula was used to help calibrate a simple whole body counter for measuring total potassium and applied to nutrition and hypertension studies. A sodium iodide detector was used for counting gamma rays emitted by potassium-40 to estimate TBK. The mean ratio (+/- S.D.) of adjusted TBK measurements to predicted values was 1.002 +/- 0.047. The ratio of lean body mass estimated by the TBK measurement to that derived from skin fold thickness was 1.069 +/- 0.056. In hypertensives on low dose thiazide, the ratio of TBK measurements to predicted values was 0.994 +/- 0.052. Thus, our TBK measurements were adjusted in close agreement with a predictor formula, provided higher estimates of lean body mass than did skin fold thickness, and showed no ...
Two ~35 day clocks in Her X-1: evidence for neutron star free precession
We present evidence for the existence of two ~35 day clocks in the Her X-1/HZ Her binary system. ~35 day modulations are observed 1) in the Turn-On cycles with two on- and two off-states, and 2) in the changing shape of the pulse profiles which re-appears regularly. The two ways of counting the 35 day cycles are generally in synchronization. This synchronization did apparently break down temporarily during the long Anomalous Low (AL3) which Her X-1 experienced in 1999/2000, in the sense that there must have been one extra Turn-On cycle. Our working hypothesis is that there are two clocks in the system, both with a period of about ~35 days: precession of the accretion disk (the less stable "Turn-On clock") and free precession of the neutron star (the more stable "Pulse profile clock"). We suggest that free precession of the neutron star is the master clock, and that the precession of the accretion disk is basically synchronized to that of the neutron star through a ...
2008-01-01
Tritium in surface waters, tap water and in precipitation in Poland during the 1994-1999 period
International Nuclear Information System (INIS)
Concentrations of tritium in environmental waters (precipitation, rivers, lakes, tap water) have been determined using electrolytic enrichment and liquid scintillation counting. In waters of big rivers (the Vistula and the Odra rivers), lakes and tap water the annual average concentrations were similar to each other being from 1.4 to 1.9 Bq x dm"-"3. These concentrations were similar to those in the precipitation in which they ranged from 1.7 to 2.2 Bq x dm"-"3. The lowest tritium concentrations were found in waters of the Seashore Region rivers (average for 1994-1999 was 1.1 Bq x dm"-"3). The tritium concentrations in surface waters and in precipitation are still higher than that of natural level. The data obtained show that tritium concentration in the water of rivers might depend on the size of drainage area. The observed seasonal variations of tritium concentration in the precipitation collected in Warsaw and at the Mount Sniezka indicate the stratospheric ...
2001-01-01
The synthesis of 5-[1-"1"1C]ethyl barbiturates from labelled malonic esters
International Nuclear Information System (INIS)
The synthesis of ["1"1C]phenobarbital, ["1"1C]pentobarbital and["1"1C]amobarbital labelled in the 5-[1-"1"1C]ethyl position is reported. The malonic esters R- CH(CO_2Et)_2 [R phenyl-, 1-methylbutyl-, and 3- methylbutyl- were alkylated with [1-"1"1C]ethyl iodide prepared from ["1"1C]carbon dioxide. Ring closure of the 2-[1-"1"1C]ethyl-labelled malonic esters with urea afforded 5-[1-"1"1C]ethyl-phenobarbital,-phenobarbital, -pentobarbital and -amobarbital synthesis times of 42-47 min, counted from ["1"1C] carbon dioxide. In typical syntheses starting with 3 GBq pentobarbitol and (81 mCi) ["1"1C]carbon dioxide, 150-215 MBq (4-6 mCi) were produced in 25-30% decay corrected -amobarbital radiochemical yields with radiochemical purities greater than 98%. (author).
The study of anemia in fowl spirochetosis using radioactive iron
International Nuclear Information System (INIS)
Radioactive iron is used to follow up some haematologic indices in birds infected with irradiated spirochetes of the Borrelia anderina species. Use is made of a total of 90 cockerels, aged two months, divided into three groups: 1st group - cockerels inoculated with spirochetes that had been gamma-irradiated at the rate of 40000 R; 2nd group - cockerels inoculated with untreated spirochetes; and 3rd group - normal cockerels. The infective material consisted of strain Rouen spirochetes of the Pamoukchii serotype. Radiometric studies were also carried out for establishing to what extent radioactive iron is incorporated in the erythrocytes and is deposited in the liver, spleen, and marrow of the investigated birds. Classical methods of investigation were employed to determine the erythrocyte, leukocyte, and thrombocyte counts, the haemoglobin content (after Sahli) as well as the erythrocyte pack after the method of Todorov. It is found that the inoculation of ...
The radiosensitivity of spermatogonial stem cells in C3H/101 F[sub 1] hybrid mice
Energy Technology Data Exchange (ETDEWEB)
The radiosensitivity of spermatogonial stem cells of C3H/HeHx101/H F[sub 1] hybrid mice was determined by counting undifferentiated spermatogonia at 10 days after X-irradiation. During the spermatogenic cycle, differences in radiosensitivity were found, which were correlated with the proliferative activity of the spermatogonial stem cells. In stage VIII[sub irr], during quiescence, the spermatogonial stem cells were most radiosensitive with a D[sub 0] of 1.4 Gy. In stages XI[sub irr]-V[sub irr], when the cells were proliferatively active, the D[sub 0] was about 2.6 Gy. Based on the D[sub 0] values for sensitive and resistant spermatogonia and on the D[sub 0] for the total population, a ratio of 45:55% of sensitive to resistant spermatogonial stem cells was estimated for cell killing. When the present data were compared with data on translocation induction obtained in mice of the same genotype, a close fit was obtained when the translocation yield (Y; in % abnormal ...
1993-12-01
The influence of a seed crystal on the texture of a bulk YBaCuO specimen
International Nuclear Information System (INIS)
To investigate the dependence of the local texture of parts of an YBaCuO specimen on the distance of the seed crystal from the position of the part of the specimen, a very good textured YBaCuO specimen was cut into 9 rectangular pieces and into 12 boundary pieces of the cylindric original specimen. From the individual parts of the YBaCuO specimen the texture was measured by neutron diffraction at the Geesthacht reactor with an equal area raster. The grid width was 1 up to 10 deviation from the cylinder axis of the original YBaCuO cylinder and 2 from 10 deviation until 20 deviation. From the sum of the counted neutrons on small circles on the pole sphere the individual values of the distributions of the angular deviations of the c-axes of the crystalline domains from the cylinder axis have been calculated. The mean deviation of the c-axes from the axis of the original cylinder increases from the inner part with the seed crystal to the boundary parts of the cylindric ...
We present a detailed spectral analysis of point-like X-ray sources in the XMM-COSMOS field. Our sample of 135 sources only includes those that have more than 100 net counts in the 0.3-10 keV energy band and have been identified through optical spectroscopy. The majority of the sources are well described by a simple power-law model with either no absorption (76%) or a significant intrinsic, absorbing column (20%).As expected, the distribution of intrinsic absorbing column densities is markedly different between AGN with or without broad optical emission lines. We find within our sample four Type-2 QSOs candidates (L_X > 10^44 erg/s, N_H > 10^22 cm^-2), with a spectral energy distribution well reproduced by a composite Seyfert-2 spectrum, that demonstrates the strength of the wide field XMM/COSMOS survey to detect these rare and underrepresented sources.
2006-01-01
The Eighth Data Release of the Sloan Digital Sky Survey: First Data from SDSS-III
Energy Technology Data Exchange (ETDEWEB)
The Sloan Digital Sky Survey (SDSS) started a new phase in August 2008, with new instrumentation and new surveys focused on Galactic structure and chemical evolution, measurements of the baryon oscillation feature in the clustering of galaxies and the quasar Ly{alpha} forest, and a radial velocity search for planets around {approx}8000 stars. This paper describes the first data release of SDSS-III (and the eighth counting from the beginning of the SDSS). The release includes 5-band imaging of roughly 5200 deg{sup 2} in the Southern Galactic Cap, bringing the total footprint of the SDSS imaging to 14,555 deg{sup 2}, or over a third of the Celestial Sphere. All the imaging data have been reprocessed with an improved sky-subtraction algorithm and a final, self-consistent recalibration and flat-field determination. This release also includes all data from the second phase of the Sloan Extension for Galactic Understanding and Evolution (SEGUE-2), consisting of ...
2011-01-01
International Nuclear Information System (INIS)
To investigate the potential causes of changes to bird communities in exurban areas, we examined the relationship between bird and macro invertebrate communities in exurbanized forest. We randomly located sampling points across a gradient of exurbanization. We used point counts to quantify bird communities and sweep netting, soil cores, pitfalls, and frass collectors to quantify macro invertebrates. Bird communities had higher richness and abundance in exurban areas compared to undeveloped forests, and lost some species of conservation concern but gained others. The macro invertebrate community was slightly more abundant in exurban areas, with a slight shift in taxonomic composition. The abundance of macro invertebrates in soil cores (but not pitfalls) predicted the abundance of ground-foraging birds. The abundance of macro invertebrates in sweep nets was not associated with the abundance of aerial insectivore birds. Exurbanization therefore appears to change bird ...
Energy Technology Data Exchange (ETDEWEB)
The goal of this DOE-supported exhibition is to demystify Einstein`s formula E = mc{sup 2} by illustrating the interchangeability of matter (m) and energy (E), c{sup 2} being the exchange rate. The exhibition has two major parts, {open_quotes}matter into energy{close_quotes} and {open_quotes}energy into matter{close_quotes}, plus a video to connect them. {open_quotes}Matter into energy{close_quotes} has now been completed and has been placed on the museum floor. Positrons from a {sup 22}Na source are annihilated to produce gamma rays that are caught in NaI detectors. The viewer can alter the alignment of the detectors and observe the consequences for the rates of single and coincident counts. The viewer can also observe the effects of placing absorbers in front of the counters. Prototype explanatory graphics were placed around the exhibit and those will probably be changed after we have some experience with their effectiveness. The connecting video is in the ...
1995-08-01
The Development of a Neutral Particle Detector for Observations of the Thermosphere
One of the least understood regions of the upper atmosphere is the thermosphere, principally due to the difficulty of making observations. The neutral atmosphere is known to be highly variable, and its composition and density varies by several orders of magnitude due to solar activity, diurnal cycles, latitude, geomagnetic activity, and gravity waves. In the past, most in-situ measurements of the neutral atmosphere have utilized detectors that are dependent on arrival angle and energy accommodation of incoming species, so that information related to nascent velocity distribution and reactive species abundances is often masked. This paper will review design concepts and laboratory tests related to the development of a novel open-ionizer, neutral particle detector for space environment measurements which can overcome these limitations. The sensor features a very large field-of-view suitable for sounding rocket missions. This time-of-flight instrument uses electron impact ionization ...
2006-12-01
Studies on the interaction of lidocaine with plasma proteins
Energy Technology Data Exchange (ETDEWEB)
This study sought to quantitate lidocaine's interaction with alpha-1-acid glycoprotein (AAG), human serum albumin (HSA), and AAG in the presence of HSA, and to determine the extent of displacement of lidocaine from its binding site(s) by selected cardiovascular drugs (dipyridamole, disopyramide and quinidine). Since the limited experimental work reported in this area has involved the use of a single lidocaine concentration, this study involved the evaluation of a range of lidocaine concentrations. Lidocaine interaction with plasma proteins (AAG and HSA) was studied at 37/sup 0/C using an isothermal equilibrium dialysis system and /sup 14/C-lidocaine HCl. A dialysis membrane (M.W. cutoff 12,000 to 14,000) separated the two chambers of each dialysis cell. The extent of /sup 14/C-lidocaine dialysis was studied with respect to both drug and protein concentrations. Aliquots of each chamber of each of the cells were subjected to liquid scintillation counting ...
1985-01-01
Salmonella radicidation of poultry carcasses
International Nuclear Information System (INIS)
This thesis reports investigations using gamma-radiation to decontaminate poultry carcasses. The application to foods of doses of ionizing radiation sufficient to reduce the number of viable specific non-sporeforming pathogenic microorganisms so that none is detectable in the treated food by any standard method is termed radicidation. The doses used in this study were at such a level that no undesirable or unfavourable side-effects occurred. The effects of these doses were studied on salmonellae and other microorganisms present in, or associated with poultry carcasses and in liquid and on solid culture media as well. Decimal reduction (D_1_0) values were estimated. These represent the dose (kGy) required to achieve a reduction in initial colony count from N_0 to 0.1 N_0. Together with the estimation of the numbers of Salmonella present per carcass the data were used to predict the effect of an ionizing radiation treatment of poultry. Data on the effect of ionizing ...
2005-09-22
Radiation-induced mutations at mouse hemoglobin loci
International Nuclear Information System (INIS)
In experiments designed to detect new mutations affecting hemoglobin, we irradiated the male or female parent in reciprocal crosses of two mouse strains that differ in alleles at the hemoglobin (Hba, Hbb) loci as well as at five other specific loci. Offspring were analyzed for hemoglobin properties (electrophoretic pattern, solubility, crystal pattern), serum albumin differences, erythrocyte lysis, reticulocyte count, and external appearance. Five hemoglobin variants were found among the mutants. In three, the genetic contribution from the irradiated father was not expressed with regard to the #alpha#-chain; one carried a tandem duplication (the first known case in the mouse) involving Hbb; and one probably resulted from double nondisjunction of chromosome 7. The finding that major chromosome aberratios can mimic hemoglobin mutations indicates the need, in similar experiments, to follow F_1 screening with thorough cytogenetic analysis. The variants in which there ...
Radiation decontamination of dry food ingredients and processing aids
International Nuclear Information System (INIS)
Radiation decontamination of dry ingredients, herbs and enzyme preparations is a technically feasible, economically viable and safe physical process. The procedure is direct, simple, requires no additives and is highly efficient. Its dose requirement is moderate. Radiation doses of 3-10 kGy (0.3-1 mrad) have proved sufficient to reduce the viable counts to a satisfactory level. Ionising radiations do not cause any significant rise in temperature. The flavour, texture or other important technological or sensory properties of most ingredients are not influenced at radiation doses necessary for satisfactory decontamination, and radiation obviates the chemical residue problem. The microflora surviving radiation decontamination of dry ingredients are more susceptible to subsequent antimicrobial treatments. Recontamination can be prevented as the product can be irradiated in its final packaging. Irradiation could be carried out in commercial containers and would result ...
Quantification of antibiotic drug potency by a two-compartment radioassay of bacterial growth
Energy Technology Data Exchange (ETDEWEB)
The two-compartment radioassay for microbial kinetics based on continuous measurement of the {sup 14}CO{sub 2} released by bacterial metabolism of 14C-labeled substrate offers a valuable approach to testing the potency of antimicrobial drugs. By using a previously validated radioassay with gram-positive and gram-negative bacteria, a group of protein synthesis inhibitors was evaluated for their effect on microbial growth kinetics. All tested drugs induced changes in both the slopes and intercepts of the growth curves. An exponential growth model was applied to quantify the drug effect on the processes of bacterial {sup 14}CO{sub 2} liberation and cell generation. The response was measured in terms of a generation rate constant. A linear dependence of the generation rate constant on the dose of spectinomycin was observed with Escherichia coli. Sigmoidal-shaped curves were found in the assays of chloramphenicol and tetracycline. The implications of dose-response curves are discussed on ...
1990-06-01
Pulmonary retention of lead: an experimental study in man
Energy Technology Data Exchange (ETDEWEB)
This human investigation of lead absorption from the lungs utilized two forms of lead, lead chloride and lead hydroxide; the former was used in picogram amounts and the latter at microgram levels. These two species of lead were selected in an attempt to simulate the range of physicochemical properties found in atmospheric lead (urban air). Aerosols labeled with lead-203 were made of comparable aerodynamic size by using sodium chloride as the deposition-determining aerosol. After brief, mouthpiece exposures, 17 subjects were followed by serial counting with a thoracic array of scintillation detectors and two leg counters. Serial blood samples were also taken. The two exposure groups showed similar total deposition values (23 vs 26%) and the same biological retention halftimes, viz., 22.6 hr. When the retention data were corrected for blood-borne /sup 203/Pb, the biological halftimes for lung lead retention averaged 13.1 and 14.2 hr, respectively, and were not ...
1980-01-01
Physics of the {sup 252}Cf-source-driven noise analysis measurement
Energy Technology Data Exchange (ETDEWEB)
The {sup 252}Cf-source-driven noise analysis method is a versatile measurements tool that has been applied to measurements for initial loading of reactors, quality assurance of reactor fuel elements, fuel processing facilities, fuel reprocessing facilities, fuel storage facilities, zero-power testing of reactors, verification of calculational methods, process monitoring, characterization of storage vaults, and nuclear weapons identification. This method`s broad range of application is due to the wide variety of time- and frequency domain signatures, each with unique properties, obtained from the measurement. The following parameters are obtained from this measurement: average detector count rates, detector multiplicities, detector autocorrelations, cross-correlation between detectors, detector autopower spectral densities, cross-power spectral densities between detectors, coherences, and ratios of spectral densities. All of these measured parameters can also be ...
1997-02-01
Physical properties of shape-controlled TiO_2 nanoparticles
International Nuclear Information System (INIS)
The synthesis of narrowly dispersed nanocrystalline TiO_2 was investigated with a surfactant aided solvothermal synthetic method in toluene solutions. When a sufficient amount of titanium isopropoxide, Ti[OCH(CH_3)_2]_4 (TIP), was added to the solution, the shapes of TiO_2 nanoparticles changed from spheres to rods. The aggregated microstructures of the nano-sized TiO_2 in systems of spheres, rods, and mixtures of spheres and rods was studied using TEM. The morphological shape of the aggregation was described in terms of the fractal dimensions. We used a box-counting method to get the fractal dimension of these systems. The fitted fractal dimensions for spheres, sphere/rod mixtures, and rods are D = 1.54, D = 1.81, and D = 1.89, respectively. The fractal dimension changed from 1.54 to 1.9 with the TIP/toluene ratio, indicating that the growth mechanism for aggregations showed different behaviors.
2005-11-01
Natural radionuclides in drinking water in Argentina
International Nuclear Information System (INIS)
As part of the national survey to evaluate natural radioactivity in the environment, concentration levels of natural uranium and "2"2"6Ra have been analyzed in over 300 drinking water samples taken from different locations in Argentina. "2"2"6Ra was determined by "2"2"2Rn emanation and liquid scintillation counting, and natural uranium by a fluorimetric procedure. Values ranging from 0.03 to 24 #mu#g.l"-"1 of natural uranium and from 0.06 to 50 #mu#g.l"-"1, were measured on drinking water samples taken from tap water systems and private wells, respectively. Concentrations up to 15 mBq.l"-"1 and to 22 mBq.l"-"1 of "2"2"6Ra were found in drinking water samples taken from tap water systems and private wells, respectively. These values are compared with the reference values accepted for drinking water. Based on the water intake rate, the age distribution and the measured concentrations, an annual collective effective dose of 1.9 man Sv and an individual committed ...
2000-05-01
Models of continuous-variable quantum computing
Energy Technology Data Exchange (ETDEWEB)
We discuss strictly efficient models for measurement-based quantum computing using physical continuous variables, such as field modes of light. Such measurement-based quantum computing (MBQC) provides a promising paradigm for quantum computation as it does not require performing unitary gates during the computation, but rather appropriate readout. Here, we introduce novel schemes for which the resource state can be reasonably and efficiently prepared, and which notably do not require having infinite squeezing or mean energy available. What is more, error correction techniques are implementable, as the logical information is stored in finite-dimensional objects grasping correlations of the quantum states. Using the ideas of computational tensor networks we discuss how to sequentially prepare suitable physical resource states with cavity QED or with non-linear optics and how to efficiently implement a computational universal set of quantum operations with feasible optical measurements ...
2009-07-01
Measurement of snow water storage in the Lake Saperior basin using aerial gamma-ray spectrometry
International Nuclear Information System (INIS)
A pilot project was started in 1977 over the Lake Superior basin to measure water storage on the land area using aerial gamma-ray spectrometry to provide hydrologic information for forecasting inflow to the lake. Two airborne surveys were made, respectively in November 1977 and March 1978 which provided estimates of the increase in snow water equivalent between these surveys. The basin is located on the Canadian Shield and consequently, the gamma radiation count rate is quite variable. The airborne results are compared with ground measurements on selected flight lines and show generally good agreement. Two equipment calibrations in the Ottawa area provided inconsistent parameter values which are consequently also reflected in the results over the Lake Superior basin. The project has demonstrated to-date that the technique can be developed into an operational system for measuring snow cover water equivalent of this vast and remote area by using well calibrated ...
1977-11-01
Measurement of relative L X-ray intensity ratio following radioactive decay and photoionization
International Nuclear Information System (INIS)
The measurements of the L X-ray intensity ratio I(L?)/I(L?), I(L?)/I(L?), I(L?)/I(L?), I(L?)/I(L?) and I(L?)/I(L?) for elements Dy, Ho, Yb, W, Hg, Tl and Pb were experimentally determined both by photon excitation, in which 59.5 keV ?-rays from a filtered radioisotope 241Am was used, and by the radioactive decay of 160Tb, 160Er, 173Lu, 182Re, 201Tl, 203Pb and 207Bi. L X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the calculated theoretical values. Theoretical values of the I(L?/L?), I(L?/L?), I(L?/L?), I(L?/L?) and I(L?/L?) intensity ratios were calculated using theoretically tabulated values of subshell photoionization cross-section, fluorescence yield, fractional X-ray emission rates, Coster-Kronig transition probabilities. It was observed that present values agree with previous theoretical and other available experimental results.
2008-05-22
Measurement of relative K X-ray intensity ratio following radioactive decay and photoionization
Energy Technology Data Exchange (ETDEWEB)
The measurements of the K X-ray intensity ratio I(K{alpha} {sub 2}/K{alpha} {sub 1}), I(K{beta} {sub 1}/K{alpha} {sub 1}) and I(K{beta}/K{alpha}) for elements V, Mn, Zn, Tc, Ru, Cd, Xe, Ba, Cs, Hg and Rn were experimentally determined both by photon excitation, in which 59.5 keV {gamma}-rays from a {sup 241}Am and 123.6 keV {gamma}-rays from a {sup 60}Co were used, and following the radioactive decay of {sup 51}Cr, {sup 55}Fe, {sup 67}Ga, {sup 99}Tc, {sup 111}In, {sup 131}I, {sup 133}Ba, {sup 133}Xe, {sup 137}Cs, {sup 201}Tl and {sup 226}Ra. K X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the theoretical values. It was observed that present values agree with the previous theoretical and other experimental results.
2007-01-15
Measurement of relative K X-ray intensity ratio following radioactive decay and photoionization
International Nuclear Information System (INIS)
The measurements of the K X-ray intensity ratio I(K#alpha# _2/K#alpha# _1), I(K#beta# _1/K#alpha# _1) and I(K#beta#/K#alpha#) for elements V, Mn, Zn, Tc, Ru, Cd, Xe, Ba, Cs, Hg and Rn were experimentally determined both by photon excitation, in which 59.5 keV #gamma#-rays from a "2"4"1Am and 123.6 keV #gamma#-rays from a "6"0Co were used, and following the radioactive decay of "5"1Cr, "5"5Fe, "6"7Ga, "9"9Tc, "1"1"1In, "1"3"1I, "1"3"3Ba, "1"3"3Xe, "1"3"7Cs, "2"0"1Tl and "2"2"6Ra. K X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the theoretical values. It was observed that present values agree with the previous theoretical and other experimental results.
2007-01-01
International Nuclear Information System (INIS)
Central Nervous System (CNS) involvement, whether primary by the Human Immunodeficiency Virus - HIV - itself, or secondary (toxoplasmosis or lymphoma) is remarkably frequent in AIDS, in 40 to 70% of cases, depending upon the author. In order to study the natural history of this illness, a cohort of 25 asymptomatic seropositive patients have been established. Every 6 months these patients undergo biological and clinical examinations, as well as Magnetic Resonance brain scans. After two examinations at a 6 month's interval, the first results are reported. Out of these 25 cases, 9 present anomalies: One patient with diffuse cerebral atrophy and 8 others with high signal intensity areas on T2 weighted sequences, like those of the Multiple Sclerosis. No relationship could be demonstrated between the existence of these lesions and various criteria such as age, sex, risk factors and T4 cells count. The nature of these lesions is not lear. They certainly indicate early ...
International Nuclear Information System (INIS)
Seven types of shellfish were irradiated by gamma ray at doses of 0, 3 and 6 kGy. Pulse photo-stimulated luminescence (PPSL) and thermoluminescence (TL) methods were employed to detect the radiation treatment. The screening of irradiation was carried out by the PPSL method followed by identification using the TL technique. Most of the irradiated shellfish were screened out correctly and only a few showed photon counts a bit higher than the lower threshold value by much lower than the upper threshold value. The TL method was employed using minerals isolated from all the control and irradiated shellfish samples by density gradient treatment. Three parameters, integrated intensities of first glow curves (TL1), ratios of first to that of second glow curves (TL1/TL2), and the shapes of maxima of first glow curves, were utilized for the identification of gamma ray treatment of shellfish. (author)
Large area, low capacitance Si(Li) detectors for high rate x-ray applications
Energy Technology Data Exchange (ETDEWEB)
Large area, single-element Si(Li) detectors have been fabricated using a novel geometry which yields detectors with reduced capacitance and hence reduced noise at short amplifier pulse-processing times. A typical device employing the new geometry with a thickness of 6 mm and an active area of 175 mm 2 has a capacitance of only 0.5 pf, compared to 2.9 pf for a conventional planar device with equivalent dimensions. These new low capacitance detectors, used in conjunction with low capacitance field effect transistors, will result in x-ray spectrometers capable of operating at very high count rates while still maintaining excellent energy resolution. The spectral response of the low capacitance detectors to a wide range of x-ray energies at 80 K is comparable to typical state-of-the-art conventional Si(Li) devices. In addition to their low capacitance, the new devices offer other advantages over conventional detectors. Detector fabrication procedures, I-V and C-V ...
1992-10-01
Is there an enhancement of muons at sea level from transient events?
In a recent study of a search for enhancements from the galactic center with muons at sea level using the TUPI muon telescope, we have found several ground level enhancements (GLEs) as very sharp peaks above the count rate background. This paper reports a consistent analysis of two GLEs observed in December 2003 and detected after an up-grade of the data acquisition system, which includes a noise filter and which allows us to verify that the GLEs are not mere background fluctuations. The main target of this study is a search for the origin of the GLEs. The results show that one of them has a strong correlation with a solar flare, while the other has an unknown origin, because there is neither a satellite report of a solar flare, nor prompt X-ray emission, and nor a excess of nuclei during the raster scan where the GLE was observed. Even so, two possibilities are analyzed: the solar flare hypothesis and the gamma ray burst (GRB) hypothesis. We show, by using the ...
2004-01-01
International Nuclear Information System (INIS)
Spices and packaging materials were exposed to gamma irradiation at a dose of 10 KGy. Luncheon was prepared with irradiated or non-irradiated spices. Prepared luncheon was packaged in irradiated or non-irradiated packaging materials. Packaged luncheon was treated with 2 KGy. Treated and untreated packaged luncheon were kept in a refrigerator (1-4 Centigrade) for 12 months. Microbiological, nutritive and chemical characteristics of luncheon were evaluated after processing and during storage; whereas, sensory quality was evaluated only after irradiation. Gamma irradiation decreased the microorganisms counts of spices, packaging materials and packed luncheon and increased the shelf-life of packaged luncheon products. No major differences in moisture, protein, fat, ph value, total acidity, lipid peroxide and volatile basic nitrogen were observed due to irradiation. Sensory evaluation showed that all the combination treated luncheon were acceptable regarding sensory ...
Iridium and PGE in sedimentary rocks; Iridium et platinoides dans les roches sedimentaires
Energy Technology Data Exchange (ETDEWEB)
The detection limit of Instrumental Neutron Activation Analysis (INAA), about a few microgram per kg, is not sufficient to determine iridium concentrations in most geological samples. Use of the coincidence counting of the 316 and 468 keV gamma-rays emitted during the decay of {sup 192}Ir, improved the sensitivity (0.01 microgram per kg). The high iridium content of the clay layers from the Cretaceous-Tertiary transition (KTB) has been considered as an evidence of the extra-terrestrial origin of the KTB mass extinction. However some results indicate that a significant part of the iridium content in sediments has a volcanic origin. Radiochemical Neutron Activation Analysis (RNAA) in some KTB samples and in basic and ultra-basic rocks show that, unlike in volcanic products, no PGE (platinoids) fractionation appears in KTB samples. The nearby chondritic PGE pattern supports an extra-terrestrial origin for the KTB iridium anomaly. 2 figs., 2 tabs., 37 refs.
1994-12-31
Inhibitory effect of minocycline on osteoclastogenesis in mouse bone marrow cells
British Library Electronic Table of Contents (United Kingdom)
Objective: To study the effects of minocycline hydrochloride (MINO) on the formation of tartrate-resistant acid phosphatase (TRAP) staining-positive multinucleated osteoclast-like cells in mouse bone marrow cells (BMCs) treated with 1@a,25(OH)"2D"3 or soluble receptor activator of nuclear factor-@kB ligand (s-RANKL). Materials and methods: Mouse BMCs were cultured in alpha-modified minimum essential medium containing foetal calf serum (10%) and tetracyclines (2.5, 5 and 10@mM), such as MINO, tetracycline hydrochloride (TC), oxytetracycline hydrochloride (OXT) or doxycycline (DOXY) in the presence of 1@a,25(OH)"2D"3 (10nM) or s-RANKL (20ng/ml) for 7 days, and the number of TRAP staining-positive osteoclast-like cells was counted. In RNA isolated from BMCs treated with 1@a,25(OH)"2D"3 or s-R...
2011-01-01
Influence of fly ash on soil physical properties and turfgrass establishment
Energy Technology Data Exchange (ETDEWEB)
A field study (1993-96) assessed the benefits of applying unusually high rates of coal fly ash from power plants as a soil amendment to enhance water retention of soils without adversely affecting growth and marketability of the turf species, centipedegrass (Eremochloa ophiuroides (Munro) Hack.) A Latin Square plot design was employed that included 0 (control, no fly ash applied), 280, 560 and 1120 MgHa {sup -1} application rates of unweathered precipitator fly ash. The fly ash was spread evenly over each plot area, rototilled, and allowed to weather under natural conditions for 8 months before seeding. High levels of soluble salts, indicated by the electrical conductivity of soil extracts, in tandem with an apparent phytotoxic effect from boron, apparently inhibited initial plant establishment as shown by substantially lower germination counts in treated soil. However, plant height and rooting depth were not adversely affected, as were the dry matter yields ...
2001-04-01
Immediate responses of forests to understorey fires during the 2010 Amazonian drought
Environmental Research Database
ObjectivesThe overall aim of this proposal is to make use of the unique opportunity afforded by the 2010 Amazonian Drought in order to quantify the basin-wide impacts of an intense forest fire season on above and below-ground carbon stocks and ecophysiological changes in forest functioning. The specific objectives relating to our research questions are: O1. Assess the causes and spatial extent of the 2010 drought in terms of basin-wide rainfall anomalies and water deficits and their relationship wi [continued...]DescriptionDespite an 82% decline in deforestation rates in Amazonia, fires are still on the rise. 2010 has been a year of severe drought and fire in Amazonia. Over the last months (July and August) the number of fire counts has reached 80% of the 2005 values, which was characterized as the drought of the century. Through the beginning of September, fire outbreaks have intensified in southwest Amazonia, including Brazil, Peru and Bolivia. This drought has ...
2011-01-30
Hematological responses after inhaling "2"3"8PuO_2: An extrapolation from beagle dogs to humans
International Nuclear Information System (INIS)
The alpha emitter plutonium-238 ("2"3"8Pu), which is produced in uranium-fueled, light-water reactors, is used as a thermoelectric power source for space applications. Inhalation of a mixed oxide form of Pu is the most likely mode of exposure of workers and the general public. Occupational exposures to "2"3"8PuO_2 have occurred in association with the fabrication of radioisotope thermoelectric generators. Organs and tissue at risk for deterministic and stochastic effects of "2"3"8Pu-alpha irradiation include the lung, liver, skeleton, and lymphatic tissue. Little has been reported about the effects of inhaled "2"3"8PuO_2 on peripheral blood cell counts in humans. The purpose of this study was to investigate hematological responses after a single inhalation exposure of Beagle dogs to alpha-emitting "2"3"8PuO_2 particles and to extrapolate results to humans.
1994-11-01
Energy Technology Data Exchange (ETDEWEB)
An algorithm is presented which describes an application independent method for reducing the number of polygonal primitives required to faithfully represent an object. Reducing polygon count without a corresponding reduction in object detail is important for: achieving interactive frame rates in scientific visualization, reducing mass storage requirements, and facilitating the transmission of large, multi-timestep geometric data sets. This paper shows how coplanar and nearly coplanar polygons can be merged into larger complex polygons and re-triangulated into fewer simple polygons than originally required. The notable contributions of this paper are: (1) a method for quickly grouping polygons into nearly coplanar sets, (2) a fast approach for merging coplanar polygon sets and, (3) a simple, robust triangulation method for polygons created by 1 and 2. The central idea of the algorithm is the notion of treating polygonal data as a collection of segments and removing ...
1993-09-01
Further evidence supporting the concurrent influence of aflatoxin and manganese
Energy Technology Data Exchange (ETDEWEB)
Trace elements, including manganese may afford protection from deleterious effects of aflatoxin. Young male Fischer rats received ip injections of aflatoxin B1 (AFB1) in dimethyl sulfoxide (DMSO), 1 mg/kg, 2 mg/kg or 4 mg/kg. Control groups received DMSO ip or no injection. All animals were intubated with 3 microCi of (/sup 54/Mn)-MnCl/sub 2/ 12 hr post-injection. Sacrifice occurred 72 hr after gavage of the radiolabel. All tested levels of AFB1 affected the loss of total body radioactivity. This response was observed within 12 hr when toxin-treated groups excreted almost 4 times more counts than controls. From 12-36 hr following radiolabel administration, AFB1 appeared to enhance excretion; by 72 hr, toxin-treated animals (especially those receiving higher doses) appeared to conserve the metal. Aflatoxicosis manifested itself through reduced body weight gain. The data provide support evidence that Mn and AFB1 biointeract.
1987-04-01
Front-End-Electronics Communication software for multiple detectors in the ALICE experiment
Energy Technology Data Exchange (ETDEWEB)
In the ALICE experiment at CERN, the Detector Control System (DCS) employs several interacting software components to accomplish its task of ensuring the correct operation and monitoring of the experiment. This paper describes the Front-End-Electronics Communication (FeeCommunication) software and its role within the DCS. The FeeCommunication software's central task is passing configuration and monitoring data between the top level DCS process control and the field devices of several detectors within ALICE. The lowest level of the FeeCommunication software runs on the DCS boards, specialized embedded systems which are in direct contact with the field devices and are physically located within the detector. The middle and upper layers run on standard PC hardware located in the counting room or other external locations. This paper focuses on the design and implementation of the FeeCommunication software and the steps that were taken to fulfill the imposed ...
2006-02-15
Fractal properties of spatial distributions of aftershocks and active faults
Energy Technology Data Exchange (ETDEWEB)
The relationship between the fractal dimensions of spatial distributions of aftershocks and pre-existing active faults is examined. Fourteen mainshocks taking place in Japan were followed by aftershocks, and the aftershocks occur in swarms around the mainshocks. The epicentral distributions of the aftershocks exhibit fractal properties, and the fractal dimensions are estimated by using the two-point correlation integral. The pre-existing active fault systems observed in the 14 aftershock regions have fractal structures, and the fractal dimensions are estimated by using the box-counting method. A positive correlation between the estimated fractal dimensions is found, and it is independent on the mainshock magnitude. The correlation shows that aftershock distributions become less clustered with increasing the fractal dimensions of active fault systems. Namely, the fractal clusters of aftershocks are put under the constraint of the fractal properties of the ...
2004-01-01
International Nuclear Information System (INIS)
The excitation cross sections by electron impact from the Cd II ground state to the laser upper state 5s_2 _2D/sub 5/2/ (Beutler state) and the laser lower state 5p _2P/sub 3/2/ (resonance state) have been measured by using a crossed-beam method of electrons and Cd"+ ions and a photon-counting method. The electron-energy region investigated was from the threshold energy (5.8 eV) for the excitation of the 5p _2P/sub 3/2/ state to 20 eV. It has been shown that the excitation cross section for the ionic Beutler state 5s_2 _2D/sub 5/2/ is of the order of 10"-_1_5 cm_2 and has a sharp peak near the threshold energy for the excitation. The excitation cross section for the resonance state 5p _2P/sub 3/2/ has also been of the order of 10"-_1_5 cm_2 and has a relatively broad maximum.
Effects of paraquat on Escherichia coli: Differences between B and K-12 strains
Energy Technology Data Exchange (ETDEWEB)
Escherichia coli B and K-12 are equally susceptible to the bacteriostatic effects of aerobic paraquat, but they differed strikingly when the lethality of paraquat was evaluated. E. coli B suffered an apparent loss of viability when briefly exposed to paraquat, whereas E. coli K-12 did not. This difference depended on the ability of the B-strain, but not the K-12 strain, to retain internalized paraquat; the B strain was killed on aerobic tryptic soy-yeast extract plates during the incubation which preceded the counting of colonies. This difference in retention of paraquat between strains was demonstrated by delayed loss of viability, by growth inhibition, and by cyanide-resistant respiration after brief exposure to paraquat, washing, and testing in fresh medium. This difference was also shown by using ({sup 14}C)paraquat. This previously unrecognized difference between E. coli B and K-12 has been the cause of apparently contradictory reports and should lead to some ...
1990-02-01
Energy Technology Data Exchange (ETDEWEB)
Clove (Caryophyllus aromaticus L.) has been used for clinical procedures. Blood constituents labeled with technetium-99m (99mTc) are used in nuclear medicine. The aim of this work was to evaluate the effects of clove extract on the labeling blood constituents with 99mTc and on the morphology of red blood cells. Blood samples were incubated with clove, stannous chloride and 99mTc. Plasma, blood cells, insoluble fractions of plasma and blood cells were separated. The radioactivity was counted and percentage of radioactivity (%ATI) to each blood fraction was calculated. The shape and morphometric parameter (perimeter/area ratio) were evaluated. Clove extract altered significantly (p<0.05) the %ATI of blood constituents and the shape of red blood cells without modifying the perimeter/area ratio. The results indicate that clove extract presents chemical compounds that interfere with the radiolabeling of blood constituents and alter the morphology of red blood ...
2007-09-15
Energy Technology Data Exchange (ETDEWEB)
This study evaluates the effect of gamma radiation on the viability of fungi and actinomycetes that contaminate medicinal plants. The relationship between the total lipids of some fungi and actinomycetes and their sensitivity to gamma radiation is also investigated. The data reveal that the viable counts of these florae decrease approximately exponentially with the radiation dose, the effective dose for the elimination of these microorganisms being about 5 kGy for all the medicinal plants under study. Response of pure cultures of fungi and actinomycetes isolated from medicinal plants to increasing absorbed doses of gamma radiation indicate that an increase in radioresistance is in the following order: Streptomyces rimosus, Fusarium solani, Nocardia kuroishii. F. oxysporum, A. fumigatus, A. flavus, A. parasiticus and A. ochraceus. The total lipid contents of molds and actinomycetes have been reported to be increased by increasing the radio-resistance of ...
1997-01-01
Dose, exposure time, and resolution in Serial X-ray Crystallography
The resolution of X-ray diffraction microscopy is limited by the maximum dose that can be delivered prior to sample damage. In the proposed Serial Crystallography method, the damage problem is addressed by distributing the total dose over many identical hydrated macromolecules running continuously in a single-file train across a continuous X-ray beam, and resolution is then limited only by the available molecular and X-ray fluxes and molecular alignment. Orientation of the diffracting molecules is achieved by laser alignment. We evaluate the incident X-ray fluence (energy/area) required to obtain a given resolution from (1) an analytical model, giving the count rate at the maximum scattering angle for a model protein, (2) explicit simulation of diffraction patterns for a GroEL-GroES protein complex, and (3) the frequency cut off of the transfer function following iterative solution of the phase problem, and reconstruction of an electron density map in the ...
2007-01-01
International Nuclear Information System (INIS)
In 576 patients quantitative scintigraphy of the sacroiliac joints and the spinal cord with "9"9"mTc-pyrophosphate was performed. 328 were patients with proven ankylosing spondylitis according to the New York criteria. 120 were patients with a clinically and roentgenologically suspected ankylosing spondylitis and 128 persons formed a healthy control group. The count rate in small regions of interest (ROI) in the sacroiliac joints, the spinal cord and the os sacrum were compared on the basis of indexes. The scintigraphic data of patients with ankylosing spondylitis were compared with the healthy control group and with the radiographic findings and radiologic staging of the disease. In a longitudinal follow-up study during 1 to 6 years these investigations were continued together with clinical and roentgenological checks. Quantitative bone scintigraphy provides characteristic indexes for ankylosing spondylitis, indicating the increased mineral metabolism of the ...
Energy Technology Data Exchange (ETDEWEB)
Twenty children with respiratory disease ingested 500 ..mu..Ci of Tc-99m sulfur colloid orally, and scintigrams of the thorax were obtained to determine whether pulmonaryaspiration of gastric contents could be detected. The children ranged in age from 1 mo to 14 y; 13 were 8 months of age or younger. Children were studied at 5 min and 4 h after ingestion of Tc-99m sulfur colloid using a high-sensitivity computer oscilloscope to record 100K-count images. Additional images were obtained after the children had slept overnight. Five children (25%) showed definite pulmonary accumulation of activity; four of these also had a barium swallow and three showed either pulmonary aspiration of barium or moderately severe gastroesophageal reflux. Oral ingestion of Tc-99m sulfur colloid provides a noninvasive means for diagnosing pulmonary aspiration under physiologic conditions in infants and children.
1980-04-01
Cytotoxic effects of WR-2721 on mouse testicular cells
Energy Technology Data Exchange (ETDEWEB)
WR-2721 (S-2-(3-aminopropylamino)ethylphosphorothioic acid) has been demonstrated to be cytotoxic to stem spermatogonia in the mouse. Five and 10 injections of 300 mg/kg killed sufficient numbers of stem cells to reduce sperm production 56 days after treatment by 16 and 43%, respectively. Single injections of 300 or 400 mg/kg of WR-2721 given 15 min after irradiation produced negligible toxicity to stem cells as measured by counts of repopulated tubules; 600 mg/kg reduced stem cell survival by 47%. Four daily injections of 300 mg/kg given 4, 3, 2, and 1 days prior to irradiation reduced stem cell survival by about 60%. The cytotoxic effects of WR-2721 on testicular stem cells at least partially explains the reduced protection factors observed in the testis with low doses of radiation and during fractionated treatments involving multiple injections of drug.
1984-09-01
Curse of Dimensionality in the Application of Pivot-based Indexes to the Similarity Search Problem
In this work we study the validity of the so-called curse of dimensionality for indexing of databases for similarity search. We perform an asymptotic analysis, with a test model based on a sequence of metric spaces $(\\Omega_d)$ from which we pick datasets $X_d$ in an i.i.d. fashion. We call the subscript $d$ the dimension of the space $\\Omega_d$ (e.g. for $\\mathbb{R}^d$ the dimension is just the usual one) and we allow the size of the dataset $n=n_d$ to be such that $d$ is superlogarithmic but subpolynomial in $n$. We study the asymptotic performance of pivot-based indexing schemes where the number of pivots is $o(n/d)$. We pick the relatively simple cost model of similarity search where we count each distance calculation as a single computation and disregard the rest. We demonstrate that if the spaces $\\Omega_d$ exhibit the (fairly common) concentration of measure phenomenon the performance of similarity search using such indexes is asymptotically linear in ...
2009-01-01
Coulomb gauge QCD as a tool for the excited spectrum
A distinct feature of Coulomb gauge QCD is that it can be formulated in terms of physical, transverse gluons and quarks alone. The state-counting is then transparent, and the gauge is suited for studies of the excited spectrum. Leaving aside exotic spectroscopy, which has been the subject of other publications, in this note I call attention on two recent applications. One is that the running quark mass in the mid-infrared can be probed from excited baryons thanks to parity doubling, a consequence of insensitivity to chiral symmetry breaking. Fast quarks are asymptotically free and behave as massless, so hadrons containing fast quarks decouple from the condensate. Their (power-law) rate of decoupling reflects on the rate of decreasing parity splittings, which can be measured. The second is that, in analogy with the Franck-Condon principle of molecular physics, the velocity distribution of the heavy quarks inside a heavy hadron can be mapped out by the velocity ...
2010-01-01
Correction for loss of track density due to overlapping track on SSNTD
Energy Technology Data Exchange (ETDEWEB)
Solid state nuclear track detectors (SSNTD) record radiation in the form of tracks. In the case of high track density, however, it is not always possible to distinguish each track separately. The track density might then be underestimated unless the loss of track number due to overlapping is compensated. An elaborated 'erosion' or curve fitting process is applied usually, for the separation of the overlapping tracks, to automatic track counting systems. This paper shows a much simpler correction method which was developed by the analogy of the correction equation for the dead time of GM counters. From a set of about 10 data obtained from high track density detectors, the equation for SSNTD can be determined by a least square fitting. Once the equation is found, true track density could be derived easily without any help of complex image processing or calculation, such as the erosion or curve fitting. This method also provides the privilege of ...
1990-06-01
International Nuclear Information System (INIS)
Dairy products doubly labeled with 45Ca and 47Ca were used to evaluate an extrinsic labeling procedure for calcium bioavailability determination. Nonfat milk, yogurt, and fresh cheese curd were prepared from caprine milk that was intrinsically labeled with 45Ca. The products were then labeled extrinsically with 47Ca and administered to rats by gavage. The 47Ca to 45Ca ratio in bone and teeth averaged about 1.00 with either milk, yogurt, or CaCl2, but the ratio was about 1.04 when dosed with cheese curd. Ca absorption, determined by whole-body counting of 47Ca, was lower (P less than 0.05) in cheese curd (59%) than in either milk (69%), yogurt (72%), or CaCl2 (72%). Expressed as percent of dose, the absorption of 47Ca was highly correlated with bone 47Ca (r = 0.973) and with bone 45Ca (r = 0.946). Correlation between tibia 47Ca and tibia 45Ca was r = 0.923. For the dairy products tested, our results indicated that extrinsic 47Ca was absorbed similarly to intrinsic ...
Comparison of LaBr_3:Ce and NaI(Tl) Scintillators for Radio-Isotope Identification Devices
International Nuclear Information System (INIS)
Lanthanum halide (LaBr_3:Ce) scintillators offer significantly better resolution (< 3% at 662 keV) relative to NaI(Tl) and have recently become commercially available in sizes large enough for the handheld, Radio-Isotope Identification Device (RIID) market. Drawbacks to lanthanum halide detectors, however, include internal radioactivity contributing to spectral counts, and a low-energy response which can cause detector resolution to be worse than that of NaI(Tl) below 100 keV. To study the potential of this new material for RIIDs we performed a series of measurements comparing a 1.5 x 1.5-inch LaBr_3:Ce detector with an Exploranium GR-135 RIID, which contains a 1.5 x 2.2-inch NaI(Tl) detector. Measurements were taken for short timeframes, as typifies RIID usage. Measurements included examples of naturally occurring radioactive material (NORM), typically found in cargo, and special nuclear materials. Some measurements were non-contact, involving short distances ...
2005-10-23
Collection and analysis of particulate from the DIII-D Tokamak
International Nuclear Information System (INIS)
Particulate (i.e. tokamak dust) has been collected from the DIII-D tokamak located at General Atomics in San Diego, CA, USA. Two methods were used to collect particulate with the goal of preserving the particle size distribution and physical characteristics of the particulate. Vacuum collection on substrates and adhesion removal with metallurgical replicating tape were chosen as non-intrusive sampling methods. Sampling was completed in four toroidal locations of the machine; the 0-90 area, the 90-180 area, the 180-270 area, and the 270-360 area. The 0 direction designates the north side of the DIII-D machine. Four tiles in each area were sampled; the first vertical tile above the floor on the centerpost, a floor tile next to the center post, a tile on the isolated ring, and the first tile up from the isolated ring on the divertor. In addition, samples were collected from underneath the floor tiles at the 275 and the 75 locations. The count median diameter of the ...
1998-09-01
Characterization of 3D thermal neutron semiconductor detectors
International Nuclear Information System (INIS)
Neutron semiconductor detectors for neutron counting and neutron radiography have an increasing importance. Simple silicon neutron detectors are combination of a planar diode with a layer of an appropriate neutron converter such as 6LiF. These devices have limited detection efficiency of not more than 5%. The detection efficiency can be increased by creating a 3D microstructure of dips, trenches or pores in the detector and filling it with a neutron converter. The first results related to the development of such devices are presented. Silicon detectors were fabricated with pyramidal dips on the surface covered with 6LiF and then irradiated by thermal neutrons. Pulse height spectra of the energy deposited in the sensitive volume were compared with simulations. The detection efficiency of these devices was about 6.3%. Samples with different column sizes were fabricated to study the electrical properties of 3D structures. Charge collection efficiencies in silicon ...
2007-06-11
Challenges in environmental monitoring and reporting
Energy Technology Data Exchange (ETDEWEB)
The Canadian Association of Petroleum Producers (CAPP) represents about 170 crude oil and natural gas exploration, development and production companies in regulatory hearings and legal proceedings. Its principal role is to enhance the economic well-being and sustainability of the Canadian upstream petroleum industry. This presentation explores the role that information technology (IT) plays in knowledge and information management and how this role relates to meeting Canada`s target for greenhouse gas emissions reductions set by the Kyoto Protocol. Actions such as the Voluntary Challenge Registry (VCR) and emissions reductions trading are re-visited and the information requirements associated with these actions are highlighted. It is shown that among others, emissions databases between jurisdictions (provincial, national, international) have to be integrated, reduction claims must be tracked, verified and cross-referenced to eliminate double counting, comprehensive ...
1998-12-31
Bone scintigraphy in fluoride treated osteoporosis
Energy Technology Data Exchange (ETDEWEB)
Quantitative bone scintigraphy was performed on 23 white females with post-menopausal osteoporosis and vertebral compression fractures. These patients were then entered into a randomized, double-blind clinical trial or sodium fluoride therapy (NaF=14, placebo=9) which included repeat bone scintigraphy every six months. Scintigraphic images were acquired for 500K counts per image over the total body with computer acquisition over the posterior thoracic and lumbar spine. Images were obtained on a wide field-of-view gamma camera two hours after injecting 15 mCi of Tc-99m MDP. Data analysis showed a significant reduction in the activity ratio of abnormal vertebral body to normal vertebral body in those patients treated with sodium fluoride (paired t-test p=0.0095). No significant change was observed in the control group of (p=0.142). These results suggest that sodium fluoride therapy promotes more rapid healing of osteoporotic vertebral fractures. They also demonstrate ...
1985-05-01
Association tests in nuclear families.
We present a conditional likelihood approach for testing linkage disequilibrium in nuclear families having multiple affected offspring. The likelihood, conditioned on the identity-by-descent (IBD) structure of the sibling genotypes, is unaffected by familial correlation in disease status that arises from linkage between a marker locus and the unobserved trait locus. Two such conditional likelihoods are compared: one that conditions on IBD and phase of the transmitted alleles and a second which conditions only on IBD of the transmitted alleles. Under the log-additive model, the first likelihood is equivalent to the allele-counting methods proposed in the literature. The second likelihood is valid under the added assumption of equal male and female recombination fractions. In a simulation study, we demonstrated that in sibships having two or three affected siblings the score test from each likelihood had the correct test size for testing disequilibrium. They also led ...
2001-01-01
British Library Electronic Table of Contents (United Kingdom)
2,2,5,7,8-Pentamethyl-6-chromanol (PMCol) was administered by gavage in rats for 28 days at dose levels of 0, 100, 500, and 2000mg/kg/day. PMCol administration induced decreases in body weight gains and food consumption, hepatotoxicity (increased TBILI, ALB, ALT, TP; increased relative liver weights; increased T4 and TSH), nephrotoxicity (increased BUN and BUN/CREAT, histopathology lesions), effect on lipid metabolism (increased CHOL), anemia, increase in WBC counts (total and differential), coagulation (FBGNand PTdarr) and hyperkeratosis of the nonglandular stomach in the 2000mg/kg/day dose group (in one or both sexes). In the 500mg/kg/day dose group, toxicity was seen to a lesser extent. In the 100mg/kg/day dose group, only increased CHOL (females) was observed. To assess the toxicity of...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
A new /sup 99m/Tc-phosphine-isocyanide complex with the general structure (/sup 99m/Tc (DEPE)/sub 2/(CNR)/sub 2/)/sup +/ has been synthesised and tested in animals and one human. In three animal species (rat, rabbit, dog), the complex is an efficient myocardial imaging agent, while in humans it remains in the blood pool. The complex is 100% protein bound in animals and humans, but whereas in humans it is attached to a 51.5 kdalton protein (probably prealbumin), in rabbits it appears to be bound to a larger macromolecule (M.W.>100 kdalton). The efficiency of the complex for blood pool labelling was tested in a human volunteer and compared with the standard in vivo red cell labelling technique with stannous pyrophosphate. A satisfactory radionuclide angiogram could be performed with less than 370 MBq of the complex. The count rate for the complex (cps/MBq) was 15% higher than that obtained with the labelled red cells and the absence of splenic activity was ...
1987-04-01
Energy Technology Data Exchange (ETDEWEB)
Brain MRI was carried out in patients with chronic liver diseases. No abnormal findings were recognized in patients with chronic viral hepatitis, while 59.2% of cirrhotics showed a symmetrically strong signal in basal ganglia on T1 weighted image in MRI. This finding significantly related with lowered Fischer`s ratio of serum amino acid, increased levels of serum phenylalanine, tyrosine and hyaluronic acid, prolonged prothrombin time and decreased platelet counts in the peripheral blood. Overt hepatic encephalopathy was observed in 6 of 34 patients with the strong signal in MRI during follow-up period, while none of patients without that finding developed hepatic encephalopathy. These results have indicated that the strong signal in basal ganglia on MRI appears in cirrhotic patients with severe liver dysfunction, and it is an useful index in the early diagnosis of latent hepatic encephalopathy. An improvement of this MRI finding was not observed by long-term oral ...
1996-03-01
International Nuclear Information System (INIS)
An aerial radiological survey was performed from 11 to 20 March 1982 over a 260-square-kilometer area centered on the Grand Gulf Nuclear Station at Port Gibson, Mississippi (the station was not yet in operation at the time of the survey). All gamma ray data were collected by flying east-west lines spaced 152 meters apart at an altitude 91 meters above ground level. Processed data showed that all gamma rays detected within the survey area were those expected from naturally occurring terrestrial background emitters. Count rates obtained from the aerial platform were converted to exposure rates at 1 meter above the ground and are presented in the form of an isoradiation contour map. The observed exposure rates were between 5 and 13 microroentgens per hour (#mu#R/h), with most of the area ranging from 9 to 10 #mu#R/h. These values include an estimated cosmic ray contribution of 3.6 #mu#R/h. The exposure rate obtained from soil samples and ionization chamber ...
An exposure chamber is described for the quantifiable addition of fine and ultrafine aerosol particulate matter directly to cells and used to demonstrate the in vitro cytotoxicity of fine 1,4-naphthoquinone particles to murine lung epithelial cells. The electrostatic particulate dosage and exposure system (EPDExS) operates on the principle of electrostatic precipitation and is shown to deposit fine and ultrafine aerosol particles directly to cells with 100% efficiency for particle diameters in the range of 40-530nm. This range is not limited by the EPDExS, but rather by the aerosolization method used for this study. Numbers of particles deposited onto the cells are counted with a condensation particle counter, negating any need to calculate or estimate particle exposure. The process of particle introduction, assessed using Trypan blue dye exclusion, had no effect on cell viability. In combination with a differential mobility classifier, the EPDExS can deliver ...
2008-06-08
We describe the Hubble Space Telescope (HST) Wide Field Camera 3 (WFC3) Early Release Science (ERS) observations in the GOODS-South field. The new WFC3 ERS data provide calibrated, drizzled mosaics with FHWM=0.07--0.15" in the near-UV (filters F225W, F275W, and F336W) and near-IR (F098W, F125W, and F160W) in typically 2 orbits per filter. Together with the existing HST/ACS GOODS-S mosaics in the BVi'z' filters, the 10-band ERS data cover 40-50 sq. arcmin to AB=26-27.0 mag (10-sigma for point sources). In this poster, we describe the: (1) scientific rationale, data taking and reduction procedures of the WFC3 ERS mosaics; (2) object cataloging and star-galaxy separation techniques used in these 10 different filters; (3) reliability and completeness of the 10-band object catalogs from the ERS mosaics; (4) object counts in 10 different filters from 0.2-1.7 microns to AB=26.0-27.0 mag; and (5) the full-color 10-band ERS images. We discuss the panchromatic structure ...
2010-01-01
On the clock paradox in the case of circular motion of the moving clock
Energy Technology Data Exchange (ETDEWEB)
Very often in many textbooks the formalism of the general theory of relativity is applied to gravitational problems. We think that it would be didactically useful to show how it can be adopted also for describing physical situations in accelerated frames of reference by working out in detail a particular case. This choice will also offer an opportunity to discuss a classical topic of relativistic physics. Indeed, we deal analytically with a version of the so-called clock paradox in which the moving clock performs a circular motion. The rest clock is denoted as (1), the rotating clock is (2), the inertial frame in which (1) is at rest and (2) moves is I and, finally, the accelerated frame in which (2) is at rest and (1) rotates is A. By using the general theory of relativity in order to describe the motion of (1) as seen in A we will show the following features. (I) A differential ageing between (1) and (2) occurs at their reunion and it has an absolute character, ...
2005-05-01
Nuclear radiation detectors on II-VI compounds
International Nuclear Information System (INIS)
Nuclear radiation detectors in integral execution were produced by successive epitaxial growth from vapor phase of Zn Te and Cd Se thin layers onto scintillating Zn Se (Te) crystals. The irradiation of combined Zn Se (Te) - Zn Te - Cd Se detectors by Cu_K_a X-rays leads to the appearance of photoreceiver e.m.f., which tends to saturation with the increase of X-ray radiation dose reaching the value of 0.34-0.40 V at 200 R/min. The short circuit current dependence of irradiation dose power is linear. The matching factor for detectors with Zn Te-Cd Se photoreceivers with different doping levels is 0.68-0.92. The absolute monochromatic sensitivity is 0.32-0.35 m A/m W at a quantum efficiency 0.58-0.61 and a time constant 2 x 10"-"4 s. The calculated dose sensitivity for Zn Se(Te)-Zn Te-Cd Se combined detectors at the irradiation with X-rays having effective energy 8.86 keV gives the value 3.9 x 10"-"7 A/cm"2 (R/min); the experimental value of dose sensitivity reaches ...
1993-10-13
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.