WorldWideScience
1

Application of BGO scintillators to absolute measurement of neutron capture cross sections between 0.01 eV and 10 eV  

Energy Technology Data Exchange (ETDEWEB)

Applying a total energy absorption {gamma}-ray detector composed of 12 bricks (5x5 cm{sup 2}, 7.5 cm thick) of Bi{sub 4}Ge{sub 3}O{sub 12}(BGO) scintillators, the absolute measurement of capture cross sections for Au and Sb has been made in an energy region between 0.01 eV and 10 eV using the linac time-of-flight method. Incident thermal neutron flux was absolutely determined by using the BGO detection system with a Sm sample. To extend the neutron flux measurement from the thermal neutron region to higher neutron energy, the {sup 10}B(n, {alpha} {gamma}) reaction was applied. Absolute capture yield for the relevant capture sample was obtained by the saturated capture yield at a large resonance of the sample. Gold was selected to investigate the application of the BGO detection system to the absolute measurement of the capture cross sections, since the {sup 197}Au(n, {gamma}){sup 198}Au reaction cross ...

1997-07-01

2

Status of neutron cross sections for reactor dosimetry  

International Nuclear Information System (INIS)

The status of neutron activation cross sections for some threshold reactions important for reactor materials dosimetry is reviewed. An attempt is made to understand and explain discrepancies between integral and differential data, using recent available experimental results. The importance of standard and benchmark neutron fields for testing differential data for reactor dosimetry is emphasized and the Interlaboratory Reaction Rate (ILRR) program, as well as a similar program pursued by the IAEA, are briefly described.

1976-07-06

3

Dose verification using a pelvic phantom in high dose rate (HDR) brachytherapy  

Energy Technology Data Exchange (ETDEWEB)

High dose rate (HDR) brachytherapy for treating a cervix carcinoma has become popular, because it eliminates many of the problems associated with conventional brachytherapy. In order to improve the clinical effectiveness with HDR brachytherapy, a dose calculation algorithm, optimization procedures, and image registrations need to be verified by comparing the dose distributions from a planning computer and those from a humanoid phantom. In this study, the humanoid phantom was fabricated in order to verify the absolute doses and the relative dose distributions. The measured doses from the humanoid phantom were then compared with the treatment planning system for the dose verification. The humanoid phantom needs to be designed such that the dose distributions can be quantitatively evaluated thermoluminescent dosimeter (TLD) chips with a dimension of 1/8 and film dosimetry with a spatial resolution of <1 mm used to measure the radiation ...

2003-07-01

4

FFTF (Fast Flux Test Facility) Reactor Characterization Program: Absolute Fission-rate Measurements  

Energy Technology Data Exchange (ETDEWEB)

Absolute fission rate measurements using modified National Bureau of Standards fission chambers were performed in the Fast Flux Test Facility at two core locations for isotopic deposits of {sup 232}Th, {sup 233}U, {sup 235}U, {sup 238}U, {sup 237}Np, {sup 239}Pu, {sup 240}Pu, and {sup 241}Pu. Monitor chamber results at a third location were analyzed to support other experiments involving passive dosimeter fission rate determinations.

1981-05-01

5

FFTF (FAST FLUX TEST FACILITY) REACTOR CHARACTERIZATION PROGRAM ABSOLUTE FISSION RATE MEASUREMENTS  

Energy Technology Data Exchange (ETDEWEB)

Absolute fission rate measurements using modified National Bureau of Standards fission chambers were performed in the Fast Flux Test Facility at two core locations for isotopic deposits of {sup 232}Th, {sup 233}U, {sup 235}U, {sup 238}U, {sup 237}Np, {sup 239}Pu, {sup 240}Pu, and {sup 241}Pu. Monitor chamber results at a third location were analyzed to support other experiments involving passive dosimeter fission rate determinations.

1981-05-01

6

Intraoperative radiation therapy at the National Cancer Institute: technical innovations and dosimetry  

Energy Technology Data Exchange (ETDEWEB)

The technical complexity of intraoperative radiotherapy (IORT) requires modification of the standard physical and dosimetric methods used in external electron beam therapy. At the National Cancer Institute, a number of technical innovations have been integrated into ongoing clinical studies of IORT. These include: (1) an electron beam applicator system that is significantly different from other IORT systems and includes customized squircle applicators; (2) peripheral dose shields; (3) a modified surgical table replacing the standard radiation treatment couch; and (4) routine use of multiple IORT fields that necessitates field matching. The IORT applicator system and related devices and techniques are dosimetrically characterized in detail both for use in the IORT program and in order to illustrate many useful facets of electron dosimetry.

1985-07-01

7

Radio cellular phones and health: Up-to-date research on human health; Radiotelephones cellulaires et sante: mise au point des recherches portant sur la sante chez l'homme  

Energy Technology Data Exchange (ETDEWEB)

Cellular telephones emit a radiofrequency electromagnetic field, part of which is absorbed in the user's head. Many studies have been conducted to look for their possible health hazard to human, at the experimental, epidemiological or clinical level. After a short recall on dosimetry, the author describes the state-of-the art about harmful and irreversible effects, up to now not confirmed, and about some benign symptoms which look absolutely actual. A causal relationship of the electromagnetic field on these benign symptoms is however not proven; other, studies are running to evaluate their possible long-term consequences. Interferences with cardiac pacemakers can easily be avoided by holding the telephone handset farther than 10 cm. (author)

1999-12-01

8

ISDD: A Computational Model of Particle Sedimentation, Diffusion and Target Cell Dosimetry for In Vitro Toxicity Studies  

Energy Technology Data Exchange (ETDEWEB)

Background: The difficulty of directly measuring cellular dose is a significant obstacle to application of target tissue dosimetry for nanoparticle and microparticle toxicity assessment. As a consequence, the target tissue paradigm for dosimetry and hazard assessment of nanoparticles has largely been ignored in favor of using metrics of exposure (e.g. ?g particle/mL culture medium, particle surface area/mL, particle number/mL). We have developed a computational model of solution particokinetics (sedimentation, diffusion) and dosimetry for non-interacting spherical particles and their agglomerates in monolayer cell culture systems. Particle transport to cells is calculated by simultaneous solution of Stokes Law (sedimentation) and the Stokes-Einstein equation (diffusion). Results: The In vitro Sedimentation, Diffusion and Dosimetry model (ISDD) was tested against measured transport rates or cellular ...

2010-11-30

9

Tachyons imply the existence of a privileged frame  

Energy Technology Data Exchange (ETDEWEB)

It is shown that the existence of faster-than-light signals (tachyons) would imply the existence (and detectability) of a privileged inertial frame and that one can avoid all problems with reversed-time order only by using absolute synchronization instead of the standard one. The connection between these results and the EPR-paradox is discussed.

1985-12-16

10

Quantum Cloning for Absolute Radiometry  

International Nuclear Information System (INIS)

In the quantum regime information can be copied with only a finite fidelity. This fidelity gradually increases to 1 as the system becomes classical. In this Letter we show how this fact can be used to directly measure the amount of radiated power. We demonstrate how these principles can be used to build a practical primary standard.

2010-08-20

11

Frequency evaluation of the doubly forbidden $^1S_0\\to ^3P_0$ transition in bosonic $^{174}$Yb  

CERN Document Server

We report an uncertainty evaluation of an optical lattice clock based on the $^1S_0\\leftrightarrow^3P_0$ transition in the bosonic isotope $^{174}$Yb by use of magnetically induced spectroscopy. The absolute frequency of the $^1S_0\\leftrightarrow^3P_0$ transition has been determined through comparisons with optical and microwave standards at NIST. The weighted mean of the evaluations is $\

2008-01-01

12

ESR/Alanine dosimetry on Wolsung Unit 1  

Energy Technology Data Exchange (ETDEWEB)

Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement result shows extremely ...

2007-07-01

13

ESR/Alanine dosimetry on Wolsung Unit 1  

International Nuclear Information System (INIS)

Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement result shows extremely ...

2007-05-10

14

Calibration methods of plane-parallel ionization chambers used in electron dosimetry; Metodos de calibracao de camaras de ionizacao de placas paralelas para dosimetria de feixes de eletrons  

Energy Technology Data Exchange (ETDEWEB)

The use of linear accelerators in radiotherapy is of great importance in Medicine, and according to international recommendations the electron beam dosimetry has to be performed using plane-parallel ionization chambers, previously calibrated in standard gamma radiation fields at accredited laboratories. In this work, calibration methods of plane-parallel ionization chambers used in dosimetry procedures of high energy electron beams of clinical accelerators were presented, tested and intercompared. The experiments were carried out using gamma radiation beams of {sup 60} Co at the Calibration Laboratory of Clinical Dosemeters at IPEN and electron beams od 4 to 16 MeV at the Radiotherapy Department of Hospital Israelita Albert Einstein, Sao Paulo. A method was chosen to be established at IPEN. Proposals of the calibration procedure, calibration certificate and data sheets are presented. (author)

1999-07-01

15

Performance testing of selected types of electronic personal dosimeters used in Sudan  

International Nuclear Information System (INIS)

Measurements were carried out for calibration and performance testing of a set of 10 electronic personal dosimeters (EPDs) at the Secondary Standard Dosimetry Laboratory of Sudan. Calibrations were carried out at three X-ray beam qualities described in ISO standard 4037 in addition to 137Cs and 60Co gamma ray beams. The experimental was performed with EPDs mounted on ICRU Slab phantom. X-ray and ?-ray beams were characterized in terms of air kerma free-in-air which were converted to the known delivered personal dose equivalent, Hp(10) using appropriate the air kerma to personal dose equivalent conversion coefficients. Dosimeters tested showed excellent energy and angular response and relative error of indication within the recommended limit for photon energies from 65 keV to 1.25 MeV. The study showed encouraging results for using electronic dosimeters in personal dosimetry.

2010-12-01

16

Future needs and requirements for AMS "1"4C standards and reference materials  

International Nuclear Information System (INIS)

"1"4C measurement uses a number of standards and reference materials with different properties. Historically the absolute calibration of "1"4C measurement was tied to 1890 wood, through the 'primary' standard of NBS-OxI (produced by the National Bureau of Standards, now NIST - National Institute of Standards and technology) subsequently replaced by NBS-OxII. These are both internationally calibrated and certified materials, whose "1"4C activities are known absolutely. A second tier of materials, often called secondary standards or reference materials, and including internationally recognised materials such as ANU-sucrose (now also IAEA-C6), Chinese - sucrose and the IAEA C1-C6 series, augmented by additional oxalic acid samples are also used routinely. The activity of these materials has been estimated from large numbers of measurements made ...

2004-08-01

17

Discrepancies in molar extinction coefficients of Fe"3"+ in Fricke dosimetry  

International Nuclear Information System (INIS)

Values of the chemical yield, G, and of the molar extinction coefficient, epsilon, for Fricke dosimetry, have been recommended by ICRU. For epsilon, the value in ICRU Reports 17 and 21, 2205 1.mol"-"1.cm"-"1, based on an analysis of 83 reported values. It was suggested that, where neither a careful wavelength calibration nor absorbance linearity checks had been performed, a standard error of 1.5% should be assumed; otherwise 0.15% could be accepted. Alternatively, the accuracy in applying this chemical dose meter was considered improved if there was an independent determination of epsilon with the same spectrophotometer as was used for the determination of the optical density of irradiated Fricke solution. The accuracy claimed for both methods remains questionable, since no complete argumentation could be given for the differences of up to 13% in the published values. Taking into account the discussion of the sources of error by Bryant, ...

1977-12-09

19

Determination of the semi-empiric relationship among the physical density, the concentration and rate between hydrogen and manganese atoms, and a manganese sulfate solution; Determinacao da relacao semi-empirica entre a densidade fisica, concentracao e razao entre atomos de hidrogenio e manganes em uma solucao de sulfato de manganes  

Energy Technology Data Exchange (ETDEWEB)

The bath of a manganese sulfate (BMS) is a system for absolute standardization of the neutron sources. This work establishes a functional relationship based on semi-empirical methods for the theoretical prediction of physical density values, concentration and rate between the hydrogen and manganese atoms presents in the solution of the BMS

2009-07-01

20

A high-sensitivity scintillation chamber for radon in gas  

Energy Technology Data Exchange (ETDEWEB)

A large scintillation chamber of 6.7 l volume for direct radon concentration measurements in gas is presented. With two 5 in. photomultipliers on opposite sides, working in coincidence, a concentration as low as about 0.5 mBq/l is detectable with 10% standard deviation after 1000 min measuring time. With the achieved background count rate of 0.42 counts/min and the counting efficiency of 0.607 for [sup 222]Rn and its progenies the absolute minimal detectable specific activity is reached with 0.17 mBq/l at about 12 000 min. The method to determine this minimum detectable activity is outlined. ((orig.))

1994-06-15

21

Characterization of Absolute-Resonant Eddy Current Probes,  

Science.gov (United States)

... Accession Number : ADD335809. Title : Characterization of Absolute-Resonant Eddy Current Probes,. Corporate Author : ...

22

The CAMAC Standard  

CERN Document Server

The CAMAC Standard

1972-01-01

23

Type tests to the automatic thermoluminescent dosimetry system acquired by the CPHR for personal dosimetry; Pruebas tipo al sistema de dosimetria termoluminiscente automatico adquirido por el CPHR para dosimetria personal  

Energy Technology Data Exchange (ETDEWEB)

The CPHR individual monitoring service acquired an automatic RADOS TLD system to improve its capacities to satisfy the increasing needs of their national customers. The TLD system consists of: two automatic TLD reader, model DOSACUS, a TLD irradiator and personal dosimeters card including slide and holders. The dosimeters were composed by this personal dosimeters card and LiF:Mg,Cu,P (model GR-200) detectors. These readers provide to detectors a constant temperature readout cycle using hot nitrogen gas. In order to evaluate the performance characteristics of the system, different performance tests recommended by the IEC 1066 standard were carried out. Important dosimetric characteristics evaluated were batch homogeneity, reproducibility, detection threshold, energy dependence, residual signal and fading. The results of the tests showed good performance characteristics of the system. (Author)

2006-07-01

24

Vacuum ultraviolet radiometry of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

In order to judge the potential fluorescent lamp applications of various low-pressure positive column discharges it is necessary to measure the absolute power emitted in the ultraviolet region of the spectrum. For rare-gas discharges the principle emission occurs in the vacuum ultraviolet so that it is difficult to measure the radiant emittance (power per unit area) of the resonance radiation by standard methods. Two independent techniques are discussed for measuring the radiant emittance of positive column discharges in the vacuum ultraviolet. These techniques are used to study xenon positive column discharges at the resonance wavelength of 147 nm. The first method relies on the measurement of the resonance level density by absorption techniques. The effective decay rate of the resonance level is then determined by the simulation of resonance radiation transport. These two quantities are combined to yield the radiant emittance at 147 nm ...

1995-10-01

25

Los Alamos second-generation system for passive and active neutron assays of drum-size containers  

International Nuclear Information System (INIS)

We describe in a comprehensive fashion the Los Alamos second-generation system for passive and active neutron assays of drum-size containers. The developmental history of this 7-year project is presented with emphasis on the pulsed active neutron technique (differential dieaway), which has achieved milligram levels of assay sensitivity for both plutonium and uranium wastes. We describe in detail the matrix effects for both passive and active neutron assays. We present in a thorough fashion our novel approach to achieving comprehensive corrections for these matrix effects using measurements made during the assays. We develop a matrix correction formalism based on separate neutron absorption and moderator indices determined from these measurements. These are presented as a series of analytic functions fitted to the data. Absolute calibrations and calibration standards are discussed, as is a practical means (pink drum measurements) of achieving ...

1972-09-17

26

Measurement of skin dose in primary irradiation of maxillary sinus carcinoma  

Energy Technology Data Exchange (ETDEWEB)

Subcutaneous involvement frequently occurs in maxillary sinus carcinoma. Radical resection does not include removal of the skin at risk. In standard postoperative wedge-pair treatment plans, the surface dose is dependent upon beam weighting, beam energy, and patient contour. Thermoluminescent dosimetry (TLD) measurements were performed to evaluate the surface dose of patients undergoing postoperative irradiation of maxillary sinus carcinoma following primary resection. When 60 Gy was delivered to isocenter with a 45 degrees wedge pair and 6 MV photons with 1 cm bolus, the subcutaneous tissues at risk received {approximately} 30 Gy. Based upon presented TLD measurements, supplemental electron beam therapy to the subcutaneous tissues if primarily involved should be considered.

1991-03-01

27

GENERALIZED ATOMIC MASS LAW  

Science.gov (United States)

Least-squares analyses were performed on a set of atomic masses using standard and generalized senaiempirical mass laws. Presumably because of errors in the assured form of the standand mass law, its least-squares coefficients can be determined at best to an accuracy of about 10%, and masses are predicted with an uncertainty of several Mev/c/sup 2/. The standard mass law was generalized by addition of shell effect and deformation terms. While the least-squares fitting of the generalized mass law is better than for the standard mass law, it is still not possible to predict atomic masses to an accuracy better than a few Mev/c/sup 2/. The nuclear deformations and the well depth . of the nuclear interaction obtained from the additional mass-law terms are in reasonable agreement with more accurate determinations by other methods. A similar statement applies to the nuclear radius constant as ...

1959-11-15

28

Absolute dimensions of unevolved O type close binaries  

Energy Technology Data Exchange (ETDEWEB)

A method is presented to derive the absolute dimensions of early-type detached binaries by combining the observed parameters with results of evolutionary computations. The method is used to obtain the absolute dimensions of nine close binaries. We find that most systems have an initial masss ratio near 1.

1984-03-15

29

Probing the origin of inertia behind spacetime deformation  

CERN Document Server

To investigate the origin and nature of inertia, we introduce a new concept of hypothetical 2D, so-called, "master-space" (MS), subject to certain rules. The MS, embedded in the background 4D-spacetime, is an indispensable individual companion to the particle of interest, without relation to every other particle. We argue that a deformation/(distortion of local internal properties) of MS is the origin of inertia. With this perspective in sight, we construct the alternative relativistic theory of inertia (RTI), which allows to compute the relativistic inertial force acting on an arbitrary point-like observer due to its "absolute acceleration". We go beyond the hypothesis of locality with an emphasis on distortion of MS, which allows to improve essentially the standard metric and other relevant geometrical structures related to the noninertial reference frame of an arbitrary accelerated observer. We compute the inertial force exerted on the ...

2011-01-01

31

A water calorimeter for high energy x-rays and electrons  

CERN Document Server

The current primary standards at NPL for the measurement of absorbed dose to water in high energy photon and electron beams are graphite calorimeters. However, the quantity of interest in radiation dosimetry is absorbed dose to water. Therefore, a new absorbed dose to water standard based on water calorimetry has been developed for use in high energy photon and electron beams. The calorimeter operates at 4 deg C, with temperature control being provided by liquid cooling. The sealed glass inner vessel of the calorimeter was designed to minimise the effect of non-water materials on the measurement of absorbed dose. The temperature sensing thermistor probes were designed and constructed so that glass is the only material in contact with high purity water inside the vessel. Initial measurements of absorbed dose to water made in 6, 10, and 19 MV photons, and 16 MeV electrons agreed, within the measurement uncertainties of ...

2000-01-01

32

Binary Pseudo-random Grating Standard for Calibration of Surface Profilometers  

Energy Technology Data Exchange (ETDEWEB)

We suggest and describe the use of a binary pseudo-random (BPR) grating as a standard test surface for measurement of the modulation transfer function (MTF) of interferometric microscopes. Knowledge of the MTF of a microscope is absolutely necessary to convert the measured height distribution of a surface undergoing metrology into an accurate power spectral density (PSD) distribution. For an'ideal' microscope with an MTF function independent of spatial frequency out to the Nyquist frequency of the detector array with zero response at higher spatial frequencies, a BPR grating would produce a flat 1D PSD spectrum, independent of spatial frequency. For a'real' instrument, the MTF is found as the square root of the ratio of the PSD spectrum measured with the BPR grating to the'ideal,' spatial frequency independent, PSD spectrum. We present the results from a measurement of the MTF of MicromapTM-570 ...

2008-01-16

33

BDTPS The BNCT Treatment Planning System jointly developed at DIMNP and JRC/IE  

CERN Document Server

The idea to couple the Treatment Planning System (TPS) to the information on the real boron distribution in the patient is the main added value of the new methodology set-up at DIMNP of University of Pisa, in collaboration with the JRC of Petten (NL). The methodology has been implemented in the new TPS, called BDTPS (Boron Distribution Treatment Planning System), which takes into account the actual boron distribution in the patient brain, while the standard TPS assumes a uniform boron distribution, absolutely far from the reality. Nowadays, Positron Emission Tomography (PET) is able to provide this in vivo information. The new TPS, based on the Monte Carlo technique, has been validated comparing the main BNCT parameters (thermal flux, boron dose, etc.) as measured during the irradiation of a special heterogeneous boron phantom (HEBOM), ad hoc designed, as calculated by the BDTPS and by the standard TPS SERA. An evident SERA ...

2003-01-01

34

Dosimetry audit on the accuracy of 192Ir brachytherapy source strength determinations in Sweden  

Energy Technology Data Exchange (ETDEWEB)

The absorbed dose delivered to the patient in brachytherapy is directly proportional to the source strength in terms of the reference air-kerma rate (RAKR). Verification of this quantity by the hospitals is widely recognized as an important part of a quality assurance program. An external audit was performed on behalf of the Secondary Standard Dosimetry Laboratory at the Swedish Radiation Protection Authority (SSI). The aim was to investigate how accurately the source-strength in 192Ir brachytherapy is determined at Swedish hospitals. The SSI reference well-type ion chamber and calibrated equipment were used to measure the RAKR of an 192Ir source in each of the 14 Swedish afterloading units. Comparisons with values determined by vendors and hospitals were made. Agreement in values of RAKR as determined by SSI, hospitals and vendors were in all cases within the +-3% uncertainty (at a coverage factor of k=2), typically guaranteed by the vendors. ...

2007-11-15

35

Performance of Brazilian thermoluminescent CaSO{sub 4}: Dy pellets in standard diagnostic radiology beams  

Energy Technology Data Exchange (ETDEWEB)

The high sensitivity of CaSO{sub 4}: Dy as a thermoluminescent material is a great advantage when dealing with low dose levels, as in diagnostic radiology procedures. However, these kinds of dosemeters present a high energy dependence that must be precisely determined in the energy range of interest. Dosimetric pellets of CaSO{sub 4}: Dy are produced at IPEN since the end of the 80 Th decade. These pellets are produced in three forms: conventional CaSO{sub 4}: Dy (50 mg); thin CaSO{sub 4}: Dy (20 mg) and CaSO{sub 4}: Dy + 10% C (20 mg). The main applications of these dosemeters are in personal and environmental dosimetry. In this study, CaSO{sub 4}: Dy pellets produced at IPEN were evaluated in diagnostic radiology standard beams. These qualities are based on the IEC 61267 standard, and they were established at an industrial X-ray system Pantak/Seifert, model ISOVOLT 160HS. Former studies evaluated CaSO{sub 4}: Dy of ...

2006-07-01

36

Evaluating noncancer effects of trichloroethylene: dosimetry, mode of action, and risk assessment.  

UK PubMed Central (United Kingdom)

Alternatives for developing chronic exposure limits for noncancer effects of trichloroethylene (TCE) were evaluated. These alternatives were organized within a framework for dose-response assessment--exposure:dosimetry...Full Text Available

2000-05-01

37

Development of radiological emergency preparedness and biological dosimetry technology  

Energy Technology Data Exchange (ETDEWEB)

Large-scale field tracer experiments have been conducted on Ulchin and Wolsung nuclear sites for the purpose of validating FADAS and of analyzing the environmental characteristics around the nuclear site. The most influential factor in atmospheric dispersion is the meteorological condition. During the experiment, meteorological data were measured on the release point and the selected positions among sampling points. Once radioactive materials are released to the atmosphere, members of public may be exposed through the environmental media such as air, soil and foods. Therefore, to protect the public, adequate countermeasures should be taken at due time for those exposure pathways. Both processes of justification and optimization are applied to a countermeasure simultaneously for decision-making. The work scope of biological research for the radiation protection had contained the search of biological microanalytic methods for the assessment of health effect by radiation and toxic agents, ...

1999-04-01

39

Absolute detection efficiency of radiation detecting system for gamma-ray from sources with high activity  

Energy Technology Data Exchange (ETDEWEB)

In this experiment, we measured the detection efficiency of gamma-scanning system of Irradiated Materials Examination Facility (IMEF) in Korea Atomic Energy Research Institute(KAERI) for the spent PWR fuel and activity known sources with high activity. We measured the absolute detection efficiency of gamma scanning system of IMEF to the {sup 137}Cs-source with 10.4 GBq and {sup 60}Co source with 25.9 GBq High-activity sources as standard sources, and a fuel burned in the KORI -1 reactor of the Kori Nuclear power plant. In analyzing, we used three peeks those were the 661.64 keV peak form {sup 137} Cs 1173.23 and 1332.51 keV{sup 60} Co sources, and 14 peaks of {sup 134}Cs and {sup 154}Eu on the spent fuel gamma spectrum which are in the energy range from 500 to 1,600 keV. We find second order equations for detection efficiency by using our experimental results. The equation show that the detection efficiency of gamma scanning system for 1 MeV ...

2003-10-01

40

Absolute detection efficiency of radiation detecting system for gamma-ray from sources with high activity  

International Nuclear Information System (INIS)

In this experiment, we measured the detection efficiency of gamma-scanning system of Irradiated Materials Examination Facility (IMEF) in Korea Atomic Energy Research Institute(KAERI) for the spent PWR fuel and activity known sources with high activity. We measured the absolute detection efficiency of gamma scanning system of IMEF to the "1"3"7Cs-source with 10.4 GBq and "6"0Co source with 25.9 GBq High-activity sources as standard sources, and a fuel burned in the KORI -1 reactor of the Kori Nuclear power plant. In analyzing, we used three peeks those were the 661.64 keV peak form "1"3"7 Cs 1173.23 and 1332.51 keV"6"0 Co sources, and 14 peaks of "1"3"4Cs and "1"5"4Eu on the spent fuel gamma spectrum which are in the energy range from 500 to 1,600 keV. We find second order equations for detection efficiency by using our experimental results. The equation show that the detection efficiency of gamma scanning system for 1 MeV gamma-ray is ...

2003-10-01

41

Hanford Internal Dosimetry Program Manual, PNL-MA-552  

Energy Technology Data Exchange (ETDEWEB)

This manual is a guide to the services provided by the Hanford Internal Dosimetry Program (IDP), which is operated by the Pacific Northwest National Laboratory.( ) for the U.S. Department of Energy Richland Operations Office, Office of River Protection and their Hanford Site contractors. The manual describes the roles of and relationships between the IDP and the radiation protection programs of the Hanford Site contractors. Recommendations and guidance are also provided for consideration in implementing bioassay monitoring and internal dosimetry elements of radiation protection programs.

2009-09-24

42

Precise measurements of alpha particle counting efficiencies and mean ranges  

International Nuclear Information System (INIS)

Precise measurements of alpha particle counting efficiencies have been made using isotropic, infinitely thin alpha emitting sources placed in direct contact with a thin, end-window, gas flow proportional detector. Except for alpha particle absorption in the window material, this geometry approaches 2#pi#, such that the only other variation in the response of the counter is from the random decay of the source. The data are fitted to the expected linear function of count rate versus window thickness and the resulting fitting parameters are used to calculate the counting efficiencies for a given thickness of window material. Counting efficiencies for 5.31, 6.06, and 8,78 MeV alpha particles have been determined from sources of "2"1"0Po and the progeny of "2"1"2Pb. For the particular counter used, the counting efficiencies in counts per alpha and their respective relative standard deviations were 0.401 #+-# 0.12%, 0.418 #+-# 0.41%, and 0.455 #+-# 0.10%. The isotropic, ...

1978-12-01

43

Utilisation of an Air-conditioning System to Control the Levels of Radon and Radon Progeny in a Workplace Environment  

Energy Technology Data Exchange (ETDEWEB)

From long-term real-time radon and radon progeny measurements taken in a relatively large retail store, cyclical patterns were evident, which were found to relate to the overriding influence of the timed air-conditioning system. Concentration of radon, radon progeny and the variability of F factor were found to depend significantly on the intermittent operation of this ventilation-air-conditioning system. After pressure equalisation remedial measures proved ineffective, the air-movement system was utilised to reduce the levels of radon and radon progeny to well within established norms applicable during working hours. It is demonstrated that the average levels for radon and radon progeny are reduced in absolute terms. This amounted to less than 12% of the general level, during designated work periods. Where air movement systems are already installed, as well as other circumstances, their regulation provides an economical solution to meeting legal and other ...

2000-07-01

44

Preparation of immission dust samples for the analysis of toxic substances in dust by atomic emission spectroscopy with inductively coupled plasma  

International Nuclear Information System (INIS)

Samples of air-dust-concentration- and air-dust-deposit measurements were digested by a standardized wet digestion procedure and the amounts of substances in the dust according to class I TA Luft by Atomic Emission Spectroscopy with Inductively Coupled Plasma (AES-ICP). The characteristic values for procedures according to VDI 2449, sheet 1, were determined for lead, vanadium, cadmium, chromium, copper, nickel and zinc. By partial automatic control of the digestion procedure the personel expenditure of work could be reduced by a factor 13. Dust filter samples were analysed without sample preparation by evaporating the material with a solid state laser. The absolute detection limit was between 1 and 100 ng/cm"2 for the elements arsenic, cadmium, cobalt, chromium, mercury, antimony, selen and thallium. For sampling by means of the Beta-Staubmeter the relative detection limits for the laser-ICP were 10-fold lower than by use of a nebulizer. ...

45

Prediction of critical properties of mixtures from the PRSV-2 equation of state: A correction for predicted critical volumes  

Energy Technology Data Exchange (ETDEWEB)

Critical properties of a fluid or fluid mixtures are important for describing fluid phase behavior, predicting physical properties, developing equations of state, and designing supercritical-fluid extraction processes, and compression and refrigeration units. The predictive capability of the Peng-Robinson-Styjek-Vera (PRSV-2) equation of state (1986) for critical properties of binary mixtures was investigated. The procedure adopted by Heidemann and Khalil (1980) and discussed by Abu-Eishah et al. (1998) was followed. An optimized value for the binary interaction parameter based on minimization of error between experimental and predicted critical temperatures was used. The standard and the average of the absolute relative deviations in critical properties are included. The predicted critical temperature and pressure for several nonpolar and polar systems agree well with experimental data and are always better than those predicted by the ...

1999-09-01

46

Measurement of gamma-ray detection efficiency in irradiated materials examination facility  

Energy Technology Data Exchange (ETDEWEB)

The detection efficiency of gamma scanning system in irradiated materials examination facility has been measured. Gamma-ray sources used in this experiment are Cs-Co standard sources a PWR spent fuel rod in which {sup 134}Cs and {sup 154}Eu peaks are clearly identified in the energy region of 500 to 1,600 keV. The distance between source and detector is about 1.6 m. A slit type collimator with 3 mm-width window and 30 mm-thick lead block are installed between source and detector. The detector is a HPGe detector. This equipment is mainly used in gamma scanning of irradiated nuclear fuel. The measured detection efficiency seems to be 1.89 x 10{sup -6} % for 1 MeV gamma-ray. With these results the activities of unknown sources could be measured. This results are expected to be used in the measurement of the absolute distribution of gamma emitting nuclides in nuclear fuel.

2001-05-01

47

Absolute CD4+ T-Lymphocyte Count as a Surrogate Marker of Pediatric HIV Disease Progression  

UK PubMed Central (United Kingdom)

BackgroundTraditionally in pediatric HIV, the CD4+ T-lymphocyte percent is used in monitoring disease progression due to the variability in absolute CD4+ T-lymphocyte...Full Text Available

2008-07-01

48

Radiotherapy quality insurance by individualized in vivo dosimetry: state of the art; Dosimetrie individuelle in vivo pour le controle de qualite en radiotherapie: etat de l'art  

Energy Technology Data Exchange (ETDEWEB)

The quality insurance in radiotherapy in the frame of highly complex technical process as Intensity modulated radiotherapy (I.M.R.T.) needs independent control of the delivered dose to the patient. Actually, up to now, most of the radiotherapy treatments rely only on computed dosimetry through a rather complicated series of linked simulation tool. This dosimetry approach requires also qualified treatment means based on cautious quality insurance procedures. However, erroneous parameters could be difficult to detect and systematical errors could happen leading to radiotherapy accidents. In this context, in vivo dosimetry has a critical role of final control of the delivered dose. As many beam incidences and ports are used for any photon therapy treatment, external control could be very tedious and time consuming. Therefore, innovations are needed for in vivo dosimetry to provide ergonomic and efficient ...

2009-06-15

49

The NASA Science Internet - An Integrated Approach to Networking ...  

Science.gov (United States)

An intemted approach to building a networking infrastructure is an absolute necessiry for meeting the multidisciplinary science networking requirements of ...

50

Direct Measurements of the Branching Fractions for $D^0 \\to K^-e^+\  

CERN Document Server

The absolute branching fractions for the decays $D^0 \\to K^-e ^+\

2004-01-01

51

Research - Keyword Index  

Wastenet

...The number of documents that contain the keyword absolute zero is: 2 EU Descartes Prizes for excellence in research and science communication EU Descartes Prizes ...for excellence in research and science communication -Chemistry Close to Absolute Zero - Descartes Prize 2000 - Winner- Ian Smith EU Descartes Prizes for excellence ...in research and science communication EU Descartes Prizes for excellence in research and science communication -Chemistry Close to Absolute Zero - Descartes Prize 2000 ...

52

Absolute fission rates in the FFTF  

Energy Technology Data Exchange (ETDEWEB)

The part of the FFTF Reactor Characterization Program reported in this paper is a measurement of absolute fission rates of eight major fuel isotopes at two different positions within the reactor. The instruments employed in these tests were fission ionization chambers for which the absolute efficiency and fissionable deposit mass assay have been rigorously established.

1981-06-01

53

Concepts in radiation protection  

International Nuclear Information System (INIS)

This monograph provides basic notions and principles in dosimetry and radiation protection in compliance with two fundamental works: IAEA Safety Series No.115 - International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources - and Publication no. 60 of International Commission on Radiological Protection. After the review of quantities and units necessary in radiation protection, the book presents the new values of dose limits as well as the values of 'radiation weighting factor', 'tissue weighting factor' and 'conversion factor intake-dose' (committed effective dose per unit intake) by ingestion and inhalation for 30 most important radionuclides. The new values of dose limits, lower than the old values, are a challenge for the radiation protection, especially of the 'public' where the dose limit diminished by a factor of five relative to the earlier edition. The new value of dose limit for ...

1996-01-01

54

Self-aligned selective-emitter plasma-etchback and passivation process for screen-printed silicon solar cells  

Energy Technology Data Exchange (ETDEWEB)

We studied whether plasma-etching techniques can use standard screen-printed gridlines as etch masks to form self-aligned, patterned-emitter profiles on multicrystalline-silicon (mc-Si) cells from Solarex. We conducted an investigation of plasma deposition and etching processes on full-size mc-Si cells processed in commercial production lines, so that any improvements obtained would be immediately relevant to the PV industry. This investigation determined that reactive ion etching (RIE) is compatible with using standard, commercial, screen-printed gridlines as etch masks to form self-aligned, selectively doped emitter profiles. This process results in reduced gridline contact resistance when followed by plasma-enhanced chemical vapor deposition (PECVD) treatments, an undamaged emitter surface easily passivated by plasma-nitride, and a less heavily doped emitter between gridlines for reduced emitter recombination. This allows for heavier doping ...

1997-10-14

55

VOLUME I11 IMISSION SYSTEM PERFORMANCE - NASA Technical Report ...  

Science.gov (United States)

Nov 8, 2010 ... Ihring Mission 11, the radiation dosimetry measurement system functioned normally and provided data on the Earth's trapped radiation belts ...

56

Luminescence dating of marine and fluvial sediments ... - GCMD - NASA  

Science.gov (United States)

INAA (instrumental neutron activation analysis) analyses have been made of subsamples of each OSL (Optically stimulated luminescence) sample, for dosimetry ...

57

Correlation between particle size, in vivo particle persistence, and lung injury.  

UK PubMed Central (United Kingdom)

Dosimetry parameters such as deposition, clearance, retention, and translocation and dissolution of inhaled particles in and to different lung compartments may be important for the persistence of particles...Full Text Available

1994-10-01

58

Statistical comparison of the effect of relative and absolute humidity on fixed-bed carbon adsorption capacity. Report for January 1987-July 1988  

Energy Technology Data Exchange (ETDEWEB)

This paper describes statistical methods used to evaluate data for toluene (at several typical operating temperatures and humidity levels) and to determine which measure of humidity (relative or absolute) is more important in determining carbon adsorption efficiency. The water content of a solvent-laden stream is critical for its control via carbon adsorption, especially at relative humidities about 50-70%. (Relative humidity is the percent of saturation: absolute humidity is the total water content.)

1989-01-01

59

Annual book of ASTM standards  

CERN Document Server

Annual book of ASTM standards

1976-01-01

60

Quantitative cerebral blood flow with Optical Coherence Tomography  

UK PubMed Central (United Kingdom)

Absolute measurements of cerebral blood flow (CBF) are an important endpoint in studies of cerebral pathophysiology. Currently no accepted method exists for in vivo longitudinal...Full Text Available

2010-02-01

61

Probe-Flaw Interactions with Eddy Current Array Probes  

Science.gov (United States)

... The development of various modeling methods for conventional eddy current probes (absolute, differential, two-port, etc.) has led to a general ...

62

High-precision Absolute Distance and Vibration Measurement using Frequency Scanned Interferometry  

CERN Document Server

In this paper, we report high-precision absolute distance and vibration measurements performed simultaneously with frequency scanned interferometry using a pair of single mode optical fibers. Absolute distance was determined by counting the interference fringes produced while scanning the laser frequency. A high-finesse Fabry-Perot interferometer(F-P) was used to determine frequency changes during scanning. Two multi-distance-measurement analysis techniques were developed to improve distance precision and to extract the amplitude and frequency of vibrations. Under laboratory conditions, a precision of 40 nm was demonstrated for an absolute distance of approximately 0.45 meters using the first analysis technique. The second analysis technique has capability to measure vibration frequencies ranging from 0.1 Hz to 100 Hz with minimal amplitude on few nanometers order without a priori knowledge.

2004-01-01

63

Enhancement of Keratinocyte Differentiation by Rose Absolute Oil  

UK PubMed Central (United Kingdom)

BackgroundThrough differentiation processes, keratinocytes provide a physical barrier to our bodies and control skin features such as moisturization, wrinkles and pigmentation. Keratinocyte...Full Text Available

2010-08-01

64

INL Advanced Radiotherapy Research Program Annual Report 2004  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the activities and major accomplishments for the Idaho National Laboratory Advanced Radiotherapy Research Program for calendar year 2004. Topics covered include boron analysis in biological samples, computational dosimetry and treatment planning software development, medical neutron source development and characterization, and collaborative dosimetry studies at the RA-1 facility in Buenos Aires, Argentina.

2005-06-01

65

XML  

Indian Academy of Sciences (India)

designed to work with companion standards ...

66

The effect of patient shield position on gonad dose during lumbar spine radiography  

Energy Technology Data Exchange (ETDEWEB)

Background: In an effort to standardise radiological practices in the Republic of Ireland, current legislation states that 'written protocols for every type of standard radiological practice shall be established'. In order to fulfil this requirement the Irish Medical Council recommends the protocols issued by the Commission of European Communitees (CEC) for adoption in the country. Whilst this document does provide good guidance with regard to various radiographic factors, patient shielding instructions are notably ambiguous. The aim of this study was to remove some of this ambiguity by defining the optimal method of positioning patient shielding in antero-posterior (AP) and lateral lumbar spine radiographic examinations. These projections were chosen on the basis of their area of coverage being in close to and in some cases including the reproductive organs. They also represent the highest source of collective population dose of any conventional ...

2010-05-15

67

The effect of patient shield position on gonad dose during lumbar spine radiography  

International Nuclear Information System (INIS)

Background: In an effort to standardise radiological practices in the Republic of Ireland, current legislation states that 'written protocols for every type of standard radiological practice shall be established'. In order to fulfil this requirement the Irish Medical Council recommends the protocols issued by the Commission of European Communitees (CEC) for adoption in the country. Whilst this document does provide good guidance with regard to various radiographic factors, patient shielding instructions are notably ambiguous. The aim of this study was to remove some of this ambiguity by defining the optimal method of positioning patient shielding in antero-posterior (AP) and lateral lumbar spine radiographic examinations. These projections were chosen on the basis of their area of coverage being in close to and in some cases including the reproductive organs. They also represent the highest source of collective population dose of any conventional radiographic ...

2010-05-01

68

Sandia National Laboratories/California site environmental report for 1997  

Energy Technology Data Exchange (ETDEWEB)

Sandia National Laboratories (SNL) is committed to conducting its operations in an environmentally safe and sound manner. It is mandatory that activities at SNL/California comply with all applicable environmental statutes, regulations, and standards. Moreover, SNL/California continuously strives to reduce risks to employees, the public, and the environment to the lowest levels reasonably possible. To help verify effective protection of public safety and preservation of the environment, SNL/California maintains an extensive, ongoing environmental monitoring program. This program monitors all significant effluents and the environment at the SNL/California site perimeter. Lawrence Livermore National Laboratory (LLNL) performs off-site external radiation monitoring for both sites. These monitoring efforts ensure that emission controls are effective in preventing contamination of the environment. As part of SNL/California`s Environmental Monitoring Program, an ...

1998-06-01

69

Radioiodine dosimetry and prediction of consequences of thyroid exposure of the Russian population following the Chernobyl accident  

International Nuclear Information System (INIS)

In the early period after the Chernobyl accident, analysis of patterns of "1"3"1I exposure of the human thyroid showed that contaminated milk was the basic source of "1"3"1I intake among the inhabitants of Russia. The equipment and techniques used for measurement of the "1"3"1I content in the thyroids of these individuals are described in this work. A model of the "1"3"1I intake, taking into account protective actions, and a method of thyroid dose calculation are discussed. The mean thyroid dose and frequency distributions of the thyroid doses to inhabitants of towns and villages of the Bryansk, Tula and Orel regions of Russia are presented. The mean dose to the thyroids of children living in the villages was 2 to 5 times higher than the dose to adult thyroids; for children living in the towns, the mean dose was 1.5 to 12 times higher. The mean thyroid mass in adult inhabitants of the Bryansk region was 27 g, which exceeded the value for a standard man (20 g) and ...

70

Physics and quality assurance of low dose rate brachytherapy  

International Nuclear Information System (INIS)

Purpose: The purpose of this course is to review the physical principles underlying design, clinical application and execution of interstitial and intracavitary implants in the classical low dose-rate (LDR) range. This year, the course will focus on quality assurance of sources, applicators and treatment planning software. In addition, development of procedures and QA checks designed optimize treatment delivery accuracy and patient safety during each individual procedure will be reviewed. The level of presentation will be designed to accommodate both physicists and physicians. Implementation of recently published AAPM Task Group reports (no. 40, 'Comprehensive Quality Assurance' and No. 43, 'Dosimetry of Interstitial Brachytherapy Sources') will be reviewed. Outline: (A) General Principles (1) QA endpoints: temporal accuracy, positional accuracy, dose delivery accuracy, and safety of the patient, personnel, and the institution (2) QA procedure development: forms, ...

71

Development of a neutron/. gamma. ray radiation monitor  

Energy Technology Data Exchange (ETDEWEB)

Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/..gamma.. ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time ..gamma.. spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded ..gamma.. spectra created by the photopeak-Compton edge combination in the plateau portion of the knee response, correcting equations using a linearized approximation to the ...

1983-01-01

72

Development of a neutron/#gamma# ray radiation monitor  

International Nuclear Information System (INIS)

Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/#gamma# ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time #gamma# spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded #gamma# spectra created by the photopeak-Compton edge combination in the plateau portion of the knee response, correcting equations using a linearized approximation to the electron ...

1983-01-01

73

Development of a Neutron/gamma Ray Radiation Monitor.  

Science.gov (United States)

Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/gamma ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time gamma spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded gamma spectra created by the photopeak-compton edge combination in the plateau portion of the knee response, correcting equations using a linearized approximation to the electron ...

1983-01-01

74

Comparisons of Monte Carlo calculations with absorbed dose determinations in flat materials using high-current, energetic electron beams  

International Nuclear Information System (INIS)

International standards and guidelines for calibrating high-dose dosimetry systems to be used in industrial radiation processing recommend that dose-rate effects on dosimeters be evaluated under conditions of use. This is important when the irradiation relies on high-current electron accelerators, which usually provide very high dose-rates. However, most dosimeter calibration facilities use low-intensity gamma radiation or low-current electron accelerators, which deliver comparatively low dose-rates. Because of issues of thermal conductivity and response, portable calorimeters cannot be practically used with high-current accelerators, where product conveyor speeds under an electron beam can exceed several meters per second and the calorimeter is not suitable for use with product handling systems. As an alternative, Monte Carlo calculations can give theoretical estimates of the absorbed dose in materials with flat or complex configurations such ...

2007-08-01

75

INTRINSIC DOSIMETRY: A POTENTIAL NEW TOOL FOR NUCLEAR FORENSICS INVESTIGATIONS  

International Nuclear Information System (INIS)

Thermoluminescence (TL) dosimetry was used to measure dose effects on the raw stock material of borosilicate container glass from different geographical locations. Effects were studied at times up to 60 days post-irradiation at doses from 0.15 to 20 Gy. The minimum detectable dose using this technique was estimated to be 0.15 Gy which is roughly equivalent to a 24 hr irradiation 1 cm from a 50 ng source of 60Co. Two peaks were identified in the TL glow curve, a relatively unstable peak around 125 C and a more stable peak around 225 C. Differences in TL glow curve shape and intensity were also observed for the glasses from different geographical origins. We investigate radiation induced defects in glass to further develop the technique of intrinsic dosimetry - the measurement of the total absorbed dose received by the walls of a container holding radioactive material. Intrinsic dosimetry is intended to be used as an ...

2010-07-11

76

Study on Control of Brain Temperature for Brain Hypothermia Treatment  

Science.gov (United States)

The brain hypothermia treatment is an attractive therapy for the neurologist because of its neuroprotection in hypoxic-ischemic encephalopathy patients. The present paper deals with the possibility of controlling the brain and other viscera in different temperatures from the viewpoint of system control. It is theoretically attempted to realize the special brain hypothermia treatment to cool only the head but to warm the body by using the simple apparatus such as the cooling cap, muffler and warming blanket. For this purpose, a biothermal system concerning the temperature difference between the brain and the other thoracico-abdominal viscus is synthesized from the biothermal model of hypothermic patient. The output controllability and the asymptotic stability of the system are examined on the basis of its structure. Then, the maximum temperature difference to be realized is shown dependent on the temperature range of the apparatus and also on the maximum gain determined from the ...

2003-01-01

77

Is the Short Distance Scale a Result of a Problem with the LMC Photometric Zero Point?  

Energy Technology Data Exchange (ETDEWEB)

I present a promising route to harmonize distance measurements based on clump giants and RR Lyrae stars. This is achieved by comparing the brightness of these distance indicators in three environments: the solar neighborhood, Galactic bulge and Large Magellanic Cloud (LMC). As a result of harmonizing the distance scales in the solar neighborhood and Baade's Window, I derive the new absolute magnitude of RR Lyrae stars, M{sub v}(RR) at [Fe/H] = -1.6 (0.59 {+-} 0.05, 0.70 {+-} 0.05). Being somewhat brighter than the statistical parallax solution, but fainter than typical results of the main sequence fitting to Hipparcos data, these values of M{sub V}(RR) favor intermediate or old ages of globular clusters. Harmonizing the distance scales in the LMC and Baade's Window, I show that the most likely distance modulus to the LMC, {mu}{sub LMC} is in the range 18.24 - 18.44. The Hubble constant of about 70 km/s/Mpc reported by the HST Key Project is based ...

2004-03-29

78

Comparison of turbo inversion recovery magnitude (TIRM) with T2-weighted turbo spin-echo and T1-weighted spin-echo MR imaging in the early diagnosis of acute osteomyelitis in children  

Energy Technology Data Exchange (ETDEWEB)

Objective. To compare turbo inversion recovery magnitude (TIRM) with standard T1-weighted (T1-W) and T2-weighted (T2-W) MR sequences in the very early detection of acute osteomyelitis in children. Materials and methods. In 15 children with osteomyelitis, 15 sets of T1-W spin-echo (SE) (TR/TE, 400-640/12-17), T2-W turbo spin-echo (TSE) (TR/TE/ETL, 3290-4465/112-120/11), and TIRM (TR/TE/TI, 4000-6120/60/160) images were acquired with a 1.0-T magnet. Contrast-to-noise (C/N) ratios and percentage of signal between lesion and normal bone marrow were analysed with a computer-assisted image analysing system in a region of interest (ROI). Results. In 13 of 15 patients, the absolute signal enhancement in a ROI on the TIRM images was better than on the T1-W SE and T2-W TSE images and in 14 of 15 cases, C/N ratios were also better on the TIRM images than on the other sequences. In the other cases, the TIRM signal was diagnostically equivalent. On the TIRM ...

1998-11-01

79

Tachyons without paradoxes  

International Nuclear Information System (INIS)

Tachyon paradoxes, including causality paradoxes, have persisted within tachyon theories and left little hope for the existence of observable tachyons. A way is presented to solve the causality paradoxes, along with two other paradoxes, by the introduction of an absolute frame of reference in which a tachyon effect may never precede its cause. Relativity for ordinary matter is unaffected by this, even if the tachyons couple to ordinary particles. Violations of the principle of relativity due to the absolute frame would appear only in the case of free tachyons.

80

Simultaneous absolute and differential operation of eddy current bobbin probes for heat exchanger tube inspection  

Energy Technology Data Exchange (ETDEWEB)

Here the authors try to dissolve some commonly held misconceptions about the operation of eddy current probes used for inspecting heat exchanger tubes. With the help of computer model results, the authors demonstrate that, for optimized operation, absolute/differential probes should be operated with coil current flowing in phase with another. This month's feature should be of interest to researchers as well as for NDT field personnel.

2000-05-01

81

Absolute absorption of ozone in the midinfrared  

Energy Technology Data Exchange (ETDEWEB)

The absolute absorption of ozone in the midinfrared has been measured relative to 253.7-nm ultraviolet absorption to an accuracy of 1% using a Bruker Fourier transform spectrometer. These new results agree with previous measurements by diode laser measurements after the latter are corrected for more recent infrared calculations and ultraviolet cross sections. They also agree with a determination based on refractive index measurements in the infrared. 16 refs., 4 figs., 3 tabs.

1992-12-20

82

Therapeutic Applications of Monte Carlo Calculations in Nuclear Medicine  

CERN Document Server

This book examines the applications of Monte Carlo (MC) calculations in therapeutic nuclear medicine, from basic principles to computer implementations of software packages and their applications in radiation dosimetry and treatment planning. It is written for nuclear medicine physicists and physicians as well as radiation oncologists, and can serve as a supplementary text for medical imaging, radiation dosimetry and nuclear engineering graduate courses in science, medical and engineering faculties. With chapters is written by recognised authorities in that particular field, the book covers the entire range of MC applications in therapeutic medical and health physics, from its use in imaging prior to therapy to dose distribution modelling targeted radiotherapy. The contributions discuss the fundamental concepts of radiation dosimetry, radiobiological aspects of targeted radionuclide therapy and the various components and ...

2003-01-01

83

Radiation technology, radiation technics and technological dosimetry in the Institute of Isotopes of the Hungarian Academy of Sciences. 1966-1981  

Energy Technology Data Exchange (ETDEWEB)

Pilot-plant irradiation began in Hungary in 1969 with the construction of a high-activity multi-purpose /sup 60/Co facility. Technologies for radiation sterilization, food handling, plastics irradiation as well as chemical dosimetry, semiconductor instrumental dosimetry, computer-based construction and control methods have been developed. Our chlorobenzene dose-meter system is used in Hungary and abroad; as a result of an IAEA-organized dosimetric intercomparison the system was adopted as a reference system. The institute has developed into a basic institute for the reconstruction and re-load of old ..gamma..-facilities as well as it serves for the planning, construction and launching of new ones in Hungary.

1982-01-01

84

Personal nuclear accident dosimetry at Sandia National Laboratories  

Energy Technology Data Exchange (ETDEWEB)

DOE installations possessing sufficient quantities of fissile material to potentially constitute a critical mass, such that the excessive exposure of personnel to radiation from a nuclear accident is possible, are required to provide nuclear accident dosimetry services. This document describes the personal nuclear accident dosimeter (PNAD) used by SNL and prescribes methodologies to initially screen, and to process PNAD results. In addition, this report describes PNAD dosimetry results obtained during the Nuclear Accident Dosimeter Intercomparison Study (NAD23), held during 12-16 June 1995, at Los Alamos National Laboratories. Biases for reported neutron doses ranged from -6% to +36% with an average bias of +12%.

1996-09-01

85

TLD assessment of mouse dosimetry during microCT imaging  

UK PubMed Central (United Kingdom)

Advances in laboratory animal imaging have provided new resources for noninvasive biomedical research. Among these technologies is microcomputed tomography (microCT) which is widely used to obtain high...Full Text Available

2008-09-01

86

Studies of neutron dosimetry  

Energy Technology Data Exchange (ETDEWEB)

A high-purity, intense, fast-neutron source has been developed at our laboratory. We describe two inexpensive, straightforward methods of determining the total number of neutrons produced and we review precautions to be taken in applying these methods. (orig.).

1997-04-01

87

Revised neutron dosimetry results for the MOTA-2A experiment in FFTF  

Energy Technology Data Exchange (ETDEWEB)

Revised neutron fluence and damage values are reported for the MOTA-2A experiment in the Fast Flux Test Facility (FFTF). This revision corrects an error with processing of the {sup 235}U(n,f) reaction. Net corrections are on the order of 5%.

1994-09-01

88

Project resumes: biological effects from electric fields associated with high-voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

Abstracts of research projects are presented in the following areas: measurements and special facilities; cellular and subcellular studies; physiology; behavior; environmental effects; modeling, scaling and dosimetry; and high voltage direct current. (ACR)

1980-01-01

89

Photon dosimetry using plastic scintillators in pulsed radiation fields  

Energy Technology Data Exchange (ETDEWEB)

Simulations and experiments have been carried out to explore using a plastic scintillator as a dosimetry probe in the vicinity of a pulsed bremsstrahlung source in the range 4 to 20 MeV. Taking advantage of the tissue-equivalent properties of this detector in conjunction with the use of a fast digital signal processor near real-time dosimetry was shown to be possible. The importance of accounting for a broad energy electron beam in bremsstrahlung production, and photon scattering and build-up, in correctly interpreting dosimetry results at long stand-off distances is highlighted by comparing real world experiments with ideal geometry simulations. Close agreement was found between absorbed energy calculations based upon spectroscopic techniques and calculations based upon signal integration, showing a ratio between 10 MeV absorbed dose to 12 MeV absorbed dose of 0.66 at a distance of 91.4 m from the accelerator. This is ...

2007-04-01

90

Final Report of the 2nd Ex-Vessel Neutron Dosimetry Installation And Evaluations for Kori Unit 3 Reactor Pressure Vessel  

International Nuclear Information System (INIS)

This report describes a neutron fluence assessment performed for the Kori Unit 3 pressure vessel beltline region based on the guidance specified in Regulatory Guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the beltline region of the pressure vessel. After Cycle 16 of reactor operation, 2nd Ex-Vessel Neutron Dosimetry Program was instituted at Kori Unit 3 to provide continuous monitoring of the beltline region of the reactor vessel. The use of the Ex-Vessel Neutron Dosimetry Program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-Vessel Neutron Dosimetry has been evaluated at the conclusion of Cycle 17

2006-06-13

91

EPR dosimetry in chemically treated fingernails  

UK PubMed Central (United Kingdom)

By using EPR measurements of radiation-induced radicals it is possible to utilize human fingernails to estimate radiation dose after-the-fact. One of the potentially limiting factors in this...Full Text Available

2007-08-01

92

Assessment of nodal target definition and dosimetry using three different techniques: implications for re-defining the optimal pelvic field in endometrial cancer  

UK PubMed Central (United Kingdom)

Purposes1. To determine the optimal pelvic nodal clinical target volume for post-operative treatment of endometrial cancer. 2. To compare the DVH of different treatment planning...Full Text Available

93

1,3-Butadiene: linking metabolism, dosimetry, and mutation induction.  

UK PubMed Central (United Kingdom)

There is increasing concern for the potential adverse health effects of human exposures to chemical mixtures. To better understand the complex interactions of chemicals within a mixture, it is essential...Full Text Available

1994-11-01

94

Tritium bioassay and dosimetry at a CANDU reactors  

Energy Technology Data Exchange (ETDEWEB)

Tritium dose management is an important aspect of the radiation protection program at CANDU type reactor sites. This paper describes the bioassay and dosimetry of tritium at CANDU reactor sites, especially for Wolsung Nuclear Power Plant. It presents a compilation of information drawn from published papers, technical reports, international and national guidelines as well as practical experience both in Korean and Canadian CANDU Nuclear Power Plants. The implementation of this program would provide a technical basis for calculations and records should be of acceptable quality and should meet overall radiation protection program objectives.

1996-07-01

95

Passive dosimetry of radon and its daughters using solid state nuclear track detectors (SSNTDs)  

Energy Technology Data Exchange (ETDEWEB)

Indoor radon is a potential health hazard for the general public, especially in buildings with poor ventilation. A variety of dosemeters have been developed and used in surveys of radon concentration measurements. In this article the passive dosemeters which are based on solid state nuclear track detectors are reviewed. The principle of passive dosimetry and the factors affecting their performance are discussed. The characteristics of SSNTD materials in relation to their behaviour under different environmental conditions are tabulated and discussed. Results of radon surveys from selected studies are also presented. (Author).

1993-01-01

96

NRC safety research priorities for reactor vessel embrittlement, annealing, and surveillance dosimetry  

Energy Technology Data Exchange (ETDEWEB)

The recent definition of a postulated thermal shock accident followed promptly by system repressurization, termed an overcooling or pressurized thermal shock accident, has set a large analysis and research effort into motion. The essential elements are concerned with defining the accident transients, evaluating the instrumentation and controls that cause the postulated accidents, and evaluating the metallurgical and structural mechanics aspects of the reactor vessel with respect to its failure potential. This paper poses the question faced by the Nuclear Regulatory Commission (NRC) for the vessel steel embrittlement, annealing, and surveillance dosimetry facets of this postulated accident and provides information on our plans for study of this problem as well as current status.

1981-10-01

97

Multicellular level dosimetry and low dose rate effects  

International Nuclear Information System (INIS)

Building on the concepts of MIRD methods described by Webber, Watson and others at this Symposium on the Dosimetry of Administered Radionuclides, we will now consider how to apply these principles to several experimentally based open-quote macroclose quotes and multicellular models. Specifically, methods to calculate absorbed dose using different types of particulate emission (alpha, beta) with a variety of antibody carriers (IgG, F(ab')_2, Fab) for radioimmunotherapy (RIT) will be reviewed. Additionally, a discussion of direct measurement methods at the multicellular level will reveal the problems of tumor absorbed dose heterogeneity when applied to animal and clinical studies.

1989-09-21

98

Dual-field rotational (DFR) technique for total-skin electron-beam therapy (TSEBT)  

Energy Technology Data Exchange (ETDEWEB)

Comparison of dosimetry measured in a noncylindrical Rando-Alderson phantom by two-field, four-field, and six-field total-skin electron-beam therapy (TSEBT) techniques with our dual-field rotational (DFR) technique reveals a superior dosimetry for the latter. Our technique of dual-field rotational DFR-TSEBT is described in detail, and its advantages and indications for the primary management of cutaneous T-cell lymphoma (CTCL) and Kaposi's sarcoma (KS) are discussed.

1987-08-01

99

Conception, realization and test of an electronic Si-LiF-Si sensor for neutron spectrometry and dosimetry  

International Nuclear Information System (INIS)

The aim of this thesis is the study of new systems devoted to the real time neutron spectrometry and dosimetry. The microelectronics technologies have been used to research a micro system integrating sensor and data processing in real time. The multi range sensor is based on many pair of semiconductor diodes placed face to face and covered by lithium fluoride. The sensor has been designed and its behavior has been simulated. Its operating in reference neutrons beams has been analyzed. (A.L.B.)

1998-01-01

100

Absolute electron scattering cross sections for the "2S#->#"2P transition in Zn"+ using energy-loss and merged-beams methods  

International Nuclear Information System (INIS)

Using the electron energy-loss method in a merged electron-ion beams geometry absolute, cascade-free excitation cross sections have been measured for the resonance "2S#->#"2P transition in Zn"+. Measurements were carried out at electron energies of below threshold (threshold at 6.011 eV) to 40 eV. Results are in very good agreement with close-coupling calculations and, away from threshold, lie below absolute line-emission cross sections which include effects of cascade into the "2P state from higher levels.

1991-02-20

102

[sup 3]He([ital n],[gamma])[sup 4]He cross section and the photodisintegration of [sup 4]He  

Energy Technology Data Exchange (ETDEWEB)

The absolute cross section of the [sup 3]He([ital n],[gamma])[sup 4]He reaction was measured at five energies between [ital E][sub [ital n

1993-11-01

103

Using and Interpreting Adjusted NNT Measures in Biomedical Research  

UK PubMed Central (United Kingdom)

The number needed to treat (NNT) is a popular effect measure to present study results in biomedical research. NNTs were originally proposed to describe the absolute effect of a new treatment compared...Full Text Available

104

Partial purification and characterization of the multiple molecular forms of staphylococcal clotting activity (coagulase).  

UK PubMed Central (United Kingdom)

The clotting activity of Staphylococcus aureus strain 104 was purified 46,000-fold, but absolute purity was not achieved. Carbohydrate content of the purified material was not more than 5%. Elution...Full Text Available

1981-12-01

105

NASA JOHNSON SPACE CENTER ORAL HISTORY PROJECT ORAL  

Science.gov (United States)

Jan 15, 2004 ... thought I would have a difficult time working with. ...... they were absolutely right, because everybody said it rained cats and dogs on the orbit ...... We know that in the military. You can ask any military ...

106

Effects of Daily Morphine Administration and Deprivation on Choice and Demand for Remifentanil and Cocaine in Rhesus Monkeys  

UK PubMed Central (United Kingdom)

Choice procedures have indicated that the relative reinforcing effectiveness of opioid drugs increases during opioid withdrawal. The demand curve, an absolute measure of reinforcer value, has not been...Full Text Available

2011-01-01

107

Concept of time in physics. Physical and philosophical investigations on the concept of time in classical and relativistic physics. Der Zeitbegriff in der Physik. Physikalische und philosophische Untersuchungen zum Zeitbegriff in der klassischen und in der relativistischen Physik  

Energy Technology Data Exchange (ETDEWEB)

In this book the notion of time in classical physics and relativity theory is discussed. After a criticism of the absolute time some alternative measures of time in mechanics are considered. Thereafter the problem of equal time at different points of the space as well as the time in different inertial systems are considered. In this framework the clock paradox is discussed. Then the Lorentz transformation is considered. Thereafter the reconstruction of the absolute time in relativity theory is described. Finally the notion of time in general relativity theory is considered.

1980-01-01

108

Absolute, cascade-free cross sections for the "2S#->#"2P transition in Zn"+ using electron-energy-loss and merged-beams methods  

International Nuclear Information System (INIS)

Absolute, cascade-free excitation cross sections in an ion have been measured for the resonance "2S#->#"2P transition in Zn"+ using electron-energy-loss and merged electron-ion beams methods. Measurements were carried out at electron energies of below threshold to 6 times threshold. Comparisons are made with 2-, 5-, and 15-state close-coupling and distorted-wave theories. There is good agreement between experiment and the 15-state close-coupling cross sections over the energy range of the calculations.

109

An Introduction to the Standard Theory of Electroweak Interactions (4/4)  

CERN Document Server

An Introduction to the Standard Theory of Electroweak Interactions (4/4)

2011-01-01

110

An Introduction to the Standard Theory of Electroweak Interactions (3/4)  

CERN Document Server

An Introduction to the Standard Theory of Electroweak Interactions (3/4)

2011-01-01

111

An Introduction to the Standard Theory of Electroweak Interactions (2/4)  

CERN Document Server

An Introduction to the Standard Theory of Electroweak Interactions (2/4)

2011-01-01

112

The result of Alanine/ESR dosimetry at Wolsung unit 1  

International Nuclear Information System (INIS)

It needs accurate estimation of radiation level for verifying machinery and cable in Nuclear Power Plant. Therefore, in this study, we used ESR(Electron Spin Resonance) system for estimate dose of Alanine dosimeter. Alanine/ESR dosimetry, already known as a dosimetric method in medical and industrial field, was applied to estimate dose quantity at cable locations within a nuclear power plant as a part of equipment qualification program. Alanine/ESR dosimetry of absorbed dose range is 1 - 100 KGy. The alanine dosimeter is not significantly affected by temperature and fading is limited to 1% per year. The alanine dosimeters were fixed on the targeted cable or nearest position to measure dose quantity to get accurate value. Alanine dosimeters were scanned by commercially used two different ESR systems, e-scan and EMX series for alanine dosimeters. To estimate more accurate dose, two environmental correction factors, irradiation temperature and ...

2008-10-01

113

Standards and guidances for limiting ionizing radiation exposure  

Energy Technology Data Exchange (ETDEWEB)

This chapter is concerned with standards and guidances for limiting radiation exposures. It is divided into three sections, each of which has several parts. Section 1: Ionizing Radiation -- Standards and Guidances Applicable to the Public: Part A, Radiation Protection Standards; Part B, Environmental Radiation Standards; Part C, Exempt Levels of Radioactivity; Part D, Protective Action Guides for Accidents. Section 2: Ionizing Radiation -- Standards Applicable to the Workplace. Section 3: Medical and Other Standards.

1992-12-31

114

On new methods for standardization of samples in activation analysis of biological materials  

International Nuclear Information System (INIS)

New standardization techniques of samples in multielement instrumental neutron-activation analysis (INAA) of biological materials (BM) are considered. New methodical developments of sample preparation techniques, BM tableting, creation of comparison standards and standardization of packing material are suggested. Correlated data on concentration of different elements in standard specimens-comparison standards are presented for mass INAA, that is: for phenol-formaldehyde resin-base and human blood-base synthetic standards. 7 refs.; 3 tabs.

1988-06-26

115

Thermoluminescent (Tl) dosimetry of slow-neutron fields at radiotherapy dose level  

Energy Technology Data Exchange (ETDEWEB)

The dosimetry for radiotherapy involving neutrons is very complicated, owing to the complexity of secondary radiation components, whose contributions to the total absorbed dose have to be discriminated, owing to the different radiobiological effects. In order to separate thermal neutrons and photons, LiF dosimeters are mostly utilized. containing different percentage of Li, like as TLD-700, TLD-100 and TLD-600, but many problems arise. In the response of TLD-700 exposed to neutron-gamma mixed fields with high neutron flux, the contribution of thermal neutrons to the Tl emission is high. Moreover. TLD-100 and TLD-600 may undergo radiation damage, and great care has to be taken in order to obtain reliable results. Other TLDs showing lower sensitivity to neutrons are proposed and experimented for such high-flux neutron fields. The faced problems and various proposed solutions are here described. (Author)

2003-07-01

116

Preparation and dosimetry of radiotherapeutic particles for arthropaties; Preparacion y dosimetria de particulas radioterapeuticas para artropatias  

Energy Technology Data Exchange (ETDEWEB)

It was developed a new formulation of macro aggregates of Samarium 153 ({sup 153} Sm-MH) for the arthropaties treatment. The radio pharmaceutic was prepared by reaction of Samarium 153 chloride (SmCl{sub 3}) in aqueous environment with sodium boron hydride in NaOH 0.5 N. The microscopic analysis shown that the particles have an average size of 4% m (range 1-14 {mu} m). The velocity of sedimentation was 0.008 cm/min with high stability in vitro in human serum. The biological studies in healthy rabbits, shown that the complex is retained inside the articulation still eight days after of the administration of the radiopharmaceutical. Likewise, it is presented the data of absorbed dose in the different target organs, which was determined by thermoluminescent dosimetry (TLD) through the use of a REMCAL phantom (radiation equivalent manikin calibration). (Author)

1999-07-01

117

On-line dosimetry for BNCT at the MIT research reactor  

Science.gov (United States)

A computer-based beam dosimetry measurement system for boron neutron capture therapy provides accurate, sensitive, and rapid readout and recording of all beam dose components, epithermal and thermal neutron flux, and gamma-ray dose rate. This dosimetric system includes input from the characterization of the epithermal neutron beam developed at the Massachusetts Institute of Technology, actual BPA pharmacokinetic data from a specific human subject being irradiated, output of MacNCTPLAN, a treatment planning system developed by the authors group, and input from the five on-line beam detectors. The purpose of this system and associated readout systems is to ensure that the desired dose is delivered to the subject within acceptable dose tolerances, e.g., {+-}5% of the target dose, and that any perturbations in the neutron beam that may occur during irradiation can be rapidly evaluated and the appropriate measures taken.

1996-12-31

118

On-line dosimetry for BNCT at the MIT research reactor  

International Nuclear Information System (INIS)

A computer-based beam dosimetry measurement system for boron neutron capture therapy provides accurate, sensitive, and rapid readout and recording of all beam dose components, epithermal and thermal neutron flux, and gamma-ray dose rate. This dosimetric system includes input from the characterization of the epithermal neutron beam developed at the Massachusetts Institute of Technology, actual BPA pharmacokinetic data from a specific human subject being irradiated, output of MacNCTPLAN, a treatment planning system developed by the authors group, and input from the five on-line beam detectors. The purpose of this system and associated readout systems is to ensure that the desired dose is delivered to the subject within acceptable dose tolerances, e.g., #+-#5% of the target dose, and that any perturbations in the neutron beam that may occur during irradiation can be rapidly evaluated and the appropriate measures taken.

1996-11-10

119

Dosimetric considerations for patients with HIP prostheses undergoing pelvic irradiation. Report of the AAPM Radiation Therapy Committee Task Group 63  

International Nuclear Information System (INIS)

This document is the report of a task group of the Radiation Therapy Committee of the AAPM and has been prepared primarily to advise hospital physicists involved in external beam treatment of patients with pelvic malignancies who have high atomic number (Z) hip prostheses. The purpose of the report is to make the radiation oncology community aware of the problems arising from the presence of these devices in the radiation beam, to quantify the dose perturbations they cause, and, finally, to provide recommendations for treatment planning and delivery. Some of the data and recommendations are also applicable to patients having implanted high-Z prosthetic devices such as pins, humeral head replacements. The scientific understanding and methodology of clinical dosimetry for these situations is still incomplete. This report is intended to reflect the current state of scientific understanding and technical methodology in clinical dosimetry for ...

2003-06-01

120

Dose dependence of semiconductor material conductivity as a means of high fluence dosimetry  

Energy Technology Data Exchange (ETDEWEB)

Dose dependences of conductivity at a temperature of 78 K for InSb and InAs single crystals under reactor fast neutron, 50 MeV proton and 80 MeV alpha particle irradiation up to fluence of 10{sup 17} cm{sup -2} are considered. Special attention is given to non-trivial, but little known semi-conductor characteristics in terms of {sigma}(F) dependence at large fluences, and also to the versatility of such dependence for all semiconductors. The behaviour of semiconductor materials conductivity dependence on fluence presented here may be used for semiconductor dosemeters characterisitic variation forecasting under large fluence measurements and in radiation emergency dosimetry. (author).

1996-12-31

121

A TLD powder dosimetry measurement system for physical models of reference man  

International Nuclear Information System (INIS)

A tissue-equivalent dosimetry system has been developed for use in absorbed dose determinations with physical models of Reference Man. The dosimeter used was a thermo-luminescent dosimeter (TLD) powder which was mixed with a 'tissue-equivalent' material and modeled to closely approximate an organ's geometry and absorption properties. A separation procedure was developed by which the TLD powder was washed and the 'tissue-equivalent' material, a wax, was dissolved and extracted following the irradiation of the model. The procedure was tested to determine losses of powder, homogeneity of the powder's distribution throughout the wax, the effects of the separation procedure upon the powder and the statistical behavior of the procedure. The results of these tests established the feasibility of the procedure. A full-scale model of the pancreas was tested and the results supported the validity of the technique. (author)

1978-12-01

122

The stability of biological standards  

UK PubMed Central (United Kingdom)

The authors emphasize the importance of stability in biological standards and discuss the steps taken to ensure the stability of International Standards and the theoretical basis of the various stability...Full Text Available

1956-01-01

123

Standardization of Ajmodadi churna, a polyherbal formulation  

UK PubMed Central (United Kingdom)

Standardization of herbal formulations is essential in order to assess the quality of drugs, based on the concentration of their active principles. This article reports on standardization of Ajmodadi...Full Text Available

2010-03-01

124

Ada Compiler Validation Summary Report: Certificate Number ...  

Science.gov (United States)

... Standards Validation Group National Computer Systems Laboratory National Institute of Standards and Technology ... STANDARD. ... (See test Ci )i3A. ...

1989-08-18

125

The Creation of a Map of Current Vertical Land Movements in the UK based on an Optimal Combination of Absolute Gravity and Continuous GPS  

Environmental Research Database

ObjectivesThe overall aim of the proposed research is explicit in the project title, i.e. the creation of a map of current vertical land movements in the UK based on an optimal combination of absolute gravity (AG) and continuous GPS (CGPS). This is consistent with specific objective (ii) of WP1.9 of the Oceans 2025 programme and is related to priority topic area 4 (application of satellite geodesy to sea level science) of the NERC Strategic Ocean Funding Initiative (SOFI). From long term geological an [continued...]DescriptionThe proposed research aims to create a map of current vertical land movements in the UK based on an optimal combination of estimates from two geodetic surveying and monitoring techniques; the measurement of absolute gravity (AG) and the use of high precision, continuous GPS (CGPS) observations. From long term geological and geophysical studies, vertical land movements in the UK are thought to be of the order of 1 to 2 ...

2009-01-31

126

Merged-beams energy-loss technique for electron-ion excitation: Absolute total cross sections for O"5"+(2s#->#2p)  

International Nuclear Information System (INIS)

A merged-beams electron-energy-loss technique is described, by which absolute cross sections can be measured for near-threshold electron-impact excitation of multipy charged ions. Results are reported here for absolute total electron-impact excitation cross sections for the O"5"+(2s#->#2p) transition from below threshold to 1.6 eV above threshold. The experimental data are in good agremeent with a seven-state close-coupling calculation throughout the energy range of the experiment. Results agree with calculations showing that more than 90% of the electrons causing excitation are ejected in the backward direction in the center-of-mass frame. This backscattering is shown in both quantum-mechanical and semiclassical calculations. Evidence is observed for high-lying metastable autoionizing states with a lifetime of approximately 0.9 #mu#s which are made to ionize by electron impact.

128

Standardization of rules for manufacturing normal electrical equipment for mining  

Energy Technology Data Exchange (ETDEWEB)

Information is provided about standardization and unification of rules for manufacturing normal electrical equipment designed for operating in underground shafts when there is no danger of explosion of gas, dust or steam. An analysis is made of the requirements included in the CEMA standard and in the state standard.

1983-01-01

129

The use of long-term and seasonal trends of elemental compounds as an aid to the identification of sources of airborne pollutants  

Energy Technology Data Exchange (ETDEWEB)

New York City data indicate that seasonal and annual variations in dispersion-normalized air pollutant concentrations appear to accurately reflect changes in source emission patterns. The normalized concentrations make it possible to observe the impact of regulatory changes on ambient air quality without these impacts being obscured by meteorological fluctuations. It is found that numerical modeling techniques and regression analysis can be powerful tools for extracting information from large sets of air quality data. The use of differential, as opposed to absolute, pollutant concentration values will reduce artifact correlations caused by seasonal, weekly, or daily meteorological fluctuations and will permit more accurate estimation of the regression coefficients. This technique was successfully applied to a set of daily pollution measurements whose absolute concentrations were found not to yield a statistically significant fit by multiple ...

1980-01-01

130

The use of long-term and seasonal trends of elemental compounds as an aid to the identification of sources of airborne pollutants  

International Nuclear Information System (INIS)

New York City data indicate that seasonal and annual variations in dispersion-normalized air pollutant concentrations appear to accurately reflect changes in source emission patterns. The normalized concentrations make it possible to observe the impact of regulatory changes on ambient air quality without these impacts being obscured by meteorological fluctuations. It is found that numerical modeling techniques and regression analysis can be powerful tools for extracting information from large sets of air quality data. The use of differential, as opposed to absolute, pollutant concentration values will reduce artifact correlations caused by seasonal, weekly, or daily meteorological fluctuations and will permit more accurate estimation of the regression coefficients. This technique was successfully applied to a set of daily pollution measurements whose absolute concentrations were found not to yield a statistically significant fit by multiple ...

131

Evaluating Point Forecasts  

CERN Document Server

Typically, point forecasting methods are compared and assessed by means of an error measure or scoring function, such as the absolute error or the squared error. The individual scores are then averaged over forecast cases, to result in a summary measure of the predictive performance, such as the mean absolute error or the (root) mean squared error. I demonstrate that this common practice can lead to grossly misguided inferences, unless the scoring function and the forecasting task are carefully matched. Effective point forecasting requires that the scoring function be specified ex ante, or that the forecaster receives a directive in the form of a statistical functional, such as the mean or a quantile of the predictive distribution. If the scoring function is specified ex ante, the forecaster can issue the optimal point forecast, namely, the Bayes rule. If the forecaster receives a directive in the form of a functional, it is critical that the ...

2009-01-01

132

Collisions between H"+ and H_2 at kilo-electron-volt energies: Absolute differential cross sections for small-angle direct, single-, and double-charge-transfer scattering  

International Nuclear Information System (INIS)

Measurements of absolute differential cross sections for H"+-H_2 direct, single-, and double-charge-transfer scattering at 0.5, 1.5, and 5.0 keV are reported at laboratory scattering angles less than 1 degree with an angular resolution of approximately 0.02 degree. The cross sections exhibit deep interference oscillations in single-charge-transfer scattering, but no such oscillations are present in direct and double-charge-transfer scattering. Theoretical cross sections derived using the diatoms-in-molecules method to describe the molecular states in a semiclassical molecular-orbital three-state close-coupling model within a semiclassical framework agree satisfactorily with the experimental results.

133

Absolute values of three neutrino masses from atmospheric mixing and an ansatz for the mixing-matrix elements  

CERN Document Server

Using data from atmospheric neutrino mixing, and a simple functional form for mixing angles, the absolute values of three neutrino masses are calculated: $m_3\\cong 5.37\\times 10^{-2} eV$, $m_2\\cong 1.94\\times 10^{-2} eV$, $m_1\\cong 1.46\\times 10^{-2} eV$. The quantities relevant for solar neutrino mixing are calculated: $(m_2^2-m_1^2) \\cong 1.63\\times 10^{-4} eV^2$, with non-maximal mixing $\\tan^2\\theta_\\sol \\cong 0.56$. The analysis gives a suggestion of a dynamical origin for the empirical, large CP-violating phase associated with an intrinsically, very small mixing angle in the quark sector.

2003-01-01

134

Absolute differential cross sections for electron capture and loss by kilo-electron-volt hydrogen atoms  

International Nuclear Information System (INIS)

This paper reports measurements of absolute differential cross sections for electron capture and loss for fast hydrogen atoms incident on H_2, N_2, O_2, Ar, and He. Cross sections have been determined in the 2.0- to 5.0-keV energy range over the laboratory angular range 0.02 degree--2 degree, with an angular resolution of 0.02 degree. The high angular resolution allows us to observe structure at small angles in some of the cross sections. Comparison of the present results with those of other authors generally shows very good agreement.

135

Absolute cross sections for near-threshold electron-impact excitation of the 3s"2"1S#->#3s3p"1P and 3s"2"1S#->#3s3p"3P transitions in Si"2"+  

International Nuclear Information System (INIS)

Absolute total cross sections for electron-impact excitation of the 3s"2"1S#->#3s3p"3P and 3s"2"1S#->#3s3p"1P transitions in Si"2"+ were measured using the merged electron-ion beams energy-loss technique. The results are compared to R-matrix close-coupling theory, which predicts a strong resonance enhancement of the cross section near the threshold for excitation of the "3P state and this is confirmed by the experiments. The observed disagreement between theory and experiment for the dipole excitation is suggested to be due to resonance interference. copyright 1997 The American Physical Society.

136

Radiation doses and somatic risk to patients during cardiac radiological procedures  

International Nuclear Information System (INIS)

The radiation dose to a series of adult and paediatric patients undergoing cardiac catheterisations and adults having percutaneous transluminal coronary angioplasty has been measured/determined directly using lithium fluoride thermoluminescent dosemeters and indirectly using an air ionisation chamber which indicated exposure-area product. Somatic and genetic risks are estimated from the dosimetry results. It is suggested that the magnitude of the radiation hazard is negligible compared with other clinical hazards associated with these procedures. (author).

1986-01-01

137

Radiation Dosimetry considerations in the safe administration of therapeutic radiopharmaceuticals  

Energy Technology Data Exchange (ETDEWEB)

A set of eight questions was put to advanced nuclear medicine physicians-in-training participating in a continuing assessment exercise in practical therapeutic nuclear oncology. Using the particular example of {sup 131}I-MIBG treatment of neuroblastoma in children, the questions were directed to the rationale of therapy and the contribution of other forms of treatment to toxic effects. The best answer to the questions are reproduced together with an introduction by the examiner, Dr. H. Turner. tabs.

1995-12-01

138

Optical Fiber Sensors from Laboratory to Field Trials: Applications and Trends at CEA LIST  

British Library Electronic Table of Contents (United Kingdom)

Fiber optic metrology developed at the CEA LIST laboratories involves fiber Bragg grating sensors, distributed Brillouin optical time domain reflectometry and optically stimulated luminescence dosimetry. Recent activities in optical fiber sensing are reviewed from laboratory experiments to field trials.

2009-01-01

139

Intrinsic Dosimetry Of Glass Containers Used To Transport Nuclear Materials: Potential Implications to the Field of Nuclear Forensics  

International Nuclear Information System (INIS)

Thermoluminescence (TL) and Electron Paramagnetic Resonance (EPR) dosimetry were used to measure dose effects in borosilicate glass with time, from 10 minutes to #approx#60 days following exposure to a dose of up to 10,000 Rad. TL and EPR results were consistent and performed similarly, with both techniques capable of achieving an estimated limit of detection of between 50-100 Rad. Three peaks were identified in the TL glow curve at roughly 110 C, 205 C, and 225 C. The intensity of the 205 C peak was the dominant peak over the time period of this study. The stability of all of the peaks with time since irradiation increased with their corresponding temperature and little or no variation was observed in the glow curve response to a specified total dose attained at different dose rates. The intensity of the 205 C peak decreased logarithmically with time regardless of total dose. Based upon a conservative limit of detection of 330 Rad, a 10,000 Rad dose would still be ...

140

Influencing factors on ESR dose assessment in irradiated chicken legs  

Energy Technology Data Exchange (ETDEWEB)

Electron spin resonance (ESR) dosimetry of irradiated chicken legs is based on the additive dose or the calibration curve methods. In both cases the practical assumption is made that the behaviour of the chicken bone does not depend on factors such as temperature during irradiation, storage conditions and dose rate. So the aim of the present work was to investigate to what extent the above mentioned factors could influence the post-irradiation dose assessment using the ESR technique. (author).

1996-12-31

141

INEEL Advanced Radiotherapy Research Program Annual Report for 2002  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the activities and major accomplishments for the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2002. Topics covered include computational dosimetry and treatment planning software development, medical neutron source development and characterization, and boron analytical chemistry.

2003-05-01

142

INEEL Advanced Radiotherapy Research Program Annual Report 2002  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the activities and major accomplishments for the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2002. Topics covered include computational dosimetry and treatment planning software development, medical neutron source development and characterization, and boron analytical chemistry.

2003-05-23

143

FY 1999 Laboratory Directed Research and Development annual report  

Energy Technology Data Exchange (ETDEWEB)

A short synopsis of each project is given covering the following main areas of research and development: Atmospheric sciences; Biotechnology; Chemical and instrumentation analysis; Computer and information science; Design and manufacture engineering; Ecological science; Electronics and sensors; Experimental technology; Health protection and dosimetry; Hydrologic and geologic science; Marine sciences; Materials science; Nuclear science and engineering; Process science and engineering; Sociotechnical systems analysis; Statistics and applied mathematics; and Thermal and energy systems.

2000-06-13

144

Electron linear accelerators for radiotherapy  

International Nuclear Information System (INIS)

Present-day requirements for radiotherapy equipment are considered. The recently developed linacs of LUE-5, LUE-25, LUE-15MM models, as well as a newly designed unified series of medical linacs of LUER-5M, LUER-20M, LUER-40M models are described in brief. The main scientific and technical problems that were solved during their construction, namely, development of accelerating structures, a radiation head, dosimetry equipment, a programming unit, a magnetic mirror etc. are described.

1983-06-01

145

Dosimetry in dental radiology. Dentascan spiral CT versus panoramic radiography  

International Nuclear Information System (INIS)

The study compares the doses absorbed by the dentomaxillary area in spiral CT and panoramic examinations. The dose measurements demonstrate that patients receive smaller doses with panoramic radiography than with spiral CT with Dentascan. After following for some variations from instrumental differences, they are in substantial agreement with literature data. Further investigations are needed considering the radiobiological risk related to the growing spread of Dentascan examinations.

1999-05-01

146

Development and evaluation for passive dosimeter using several solid dosimeters  

International Nuclear Information System (INIS)

Passive dosimeters for personal and area radiation monitor in space have been developed mainly for dosimetry in low-earth-orbit (LEO) radiation environments of Space Shuttles and the International Space Station. The responses of several dosimeters have been evaluated by heavy ions and also its variation for individual dosimeter element. (author)

2005-05-01

147

Comparative study of convolution, superposition, and fast superposition algorithms in conventional radiotherapy, three-dimensional conformal radiotherapy, and intensity modulated radiotherapy techniques for various sites, done on CMS XIO planning system  

UK PubMed Central (United Kingdom)

The aim of this study is to compare the dosimetry results that are obtained by using Convolution, Superposition and Fast Superposition algorithms in Conventional Radiotherapy, Three-Dimensional Conformal...Full Text Available

2009-01-01

148

Clinical helical tomotherapy commissioning dosimetry  

International Nuclear Information System (INIS)

Helical tomotherapy presented many unique dosimetric challenges and solutions during the initial commissioning process, and some of them are presented. The dose calculation algorithm is convolution/superposition based. This requires that the energy fluence spectrum and magnitude be quantified. The methodology for doing so is described. Aspects of the energy fluence characterization that are unique to tomotherapy are highlighted. Many beam characteristics can be measured automatically by an included megavoltage computed tomography imaging system. This greatly improves data collection efficiency.

2003-12-01

149

Automated remote positioning and examination of FFTF reactor power characterization dosimeters  

Energy Technology Data Exchange (ETDEWEB)

The Fast Flux Test Facility (FFTF) reactor characterization by the Hanford Engineering Development Laboratory (HEDL) includes extensive neutronic measurements during startup and initial operation. To aid in the handling and counting of the thousands of passive dosimeters used as part of this effort, an automated dosimetry specimen handling, positioning, and counting system was designed and developed by Westinghouse Hanford for the Department of Energy.

1981-05-04

150

Applications of Bonner sphere detectors in neutron field dosimetry  

Energy Technology Data Exchange (ETDEWEB)

The theory of neutron moderation and spectroscopy are briefly reviewed, and moderators that are useful for Bonner sphere spectrometers are discussed. The choice of the neutron detector for a Bonner sphere spectrometer is examined. Spectral deconvolution methods are briefly reviewed, including derivative, parametric, quadrature, and Monte Carlo methods. Calibration is then discussed. (LEW)

1983-09-01

151

6. Workshop on heavy-charged particles in biology and medicine. Book of abstracts  

Energy Technology Data Exchange (ETDEWEB)

Topics of this proceedings are: DNA damage and repair; Space research; Cell and tissue radiobiology; Treatment planning 1: The role of clinical RBEs; Treatment planning 2: Dose optimization and inverse planning; Dosimetry; Clinical results of particle therapy and new techniques; Status reports and future developments. Separate abstracts were prepared for 79 chapters. (orig./SR)

1997-09-01

152

PRA QUALITY IN REGULATORY DECISIONS  

Science.gov (United States)

ASME PRA STANDARD FOR PRA. FOR NPP APPLICATION. " Provides a Standard for performing and using a. PRA. Definitions. Risk assessment ...

154

MRI evaluation and image processing in gel dosimetry. A study of selected MRI properties and image processing in 3D gel dosimetry  

Energy Technology Data Exchange (ETDEWEB)

Gel dosimetry is a new dosimetry method applied in radiation therapy. Gel dosimeters consist of a radiation sensitive gel, which can integrate absorbed doses from several radiation sources or beams. The dose to the gel can be evaluated by magnetic resonance imaging (MRI), a procedure that is the focus of the present thesis. A robust tool for the evaluation of the nonuniformity in MRI has been developed, the Deviation Image method. Unlike previously presented methods, the Deviation Image method includes all nonuniformity variations across a phantom surface and is insensitive to stochastic noise. Methods for the estimation of stochastic noise were analyzed in terms of sensitivity to nonuniformities. A method that averages the stochastic noise level over five regions over the phantom surface, and a method that assesses the stochastic noise level from the background, were found to be the methods of choice. Pronounced MR image nonuniformity ...

2001-03-01

155

Synthesis and stereochemical effects of pyrrolidinyl-acetylenic thieno[3,2-d]pyrimidines as EGFR and ErbB-2 inhibitors  

British Library Electronic Table of Contents (United Kingdom)

A novel class of pyrrolidinyl-acetyleneic thieno[3,2-d]pyrimidines has been identified which potently inhibit the EGFR and ErbB-2 receptor tyrosine kinases. Synthetic modifications of the pyrrolidine carbamate moiety result in a range of effects on enzyme and cellular potency. In addition, the impact of the absolute stereochemical configuration on cellular potency and oral mouse pharmacokinetics is described.

2009-01-01

156

Significance of cranial computer tomography for the early diagnosis of peri- and postnatal damage  

Energy Technology Data Exchange (ETDEWEB)

It is reported on examination-technical possibilities with craniocerebral Computer Tomography in the peri- and postnatal period. Some typical tomographic images from a 17 1/2 months period in our own patient material of 327 children are demonstrated. The special advantages of this new technical-extensive method are: exact diagnoses, observation possibility of the longitudinal section, and the absolute harmlessness to the child.

1981-01-01

157

Seeking nature of God in Big Bang T1 the secrets to the beginning of the universe could lie underground in Switzerland.  

CERN Multimedia

Joanna Geary joined a Birmingham University team of scientists working on the project in Geneva. Simond Hadley took the pictures. "The most exciting thing of all" says professor Peter Watkins with a smile, "is we have absolutely no idea what will happen until we switch it on."

2008-01-01

158

Quantitative transfer of the molybdenum cofactor from xanthine oxidase and from sulphite oxidase to the deficient enzyme of the nit-1 mutant of Neurospora crassa to yield active nitrate reductase.  

UK PubMed Central (United Kingdom)

An assay method is described for measurement of absolute concentrations of the molybdenum cofactor, based on complementation of the defective nitrate reductase ('apo nitrate reductase') in extracts...Full Text Available

1984-04-15

159

Monitoring for Xenon Radionuclides and CTBT Verification  

International Nuclear Information System (INIS)

The Comprehensive Nuclear-Test-Ban-Treaty (CTBT), which was opened for signature in 1996, bans all nuclear explosions in all environments. Republic of Korea has been working to monitor compliance with CTBT by deterring and detecting any nuclear explosions conducted anywhere on Earth. For the verification of CTBT, several techniques are implemented. Radionuclide monitoring is of particular importance since it is the only method which can provide absolute assurance that a nuclear detonation has occurred

2010-10-01

160

Mediation of bone ingrowth in porous hydroxyapatite bone graft substitutes.  

Science.gov (United States)

Previous investigations have shown that both the early biological response and the mechanical properties of a porous hydroxyapatite bone graft substitute are highly sensitive to its pore structure. The objective of this study was to evaluate whether the pore structure continued to influence bone integration in the medium to long term. Two screened batches of porous hydroxyapatite (PHA) designated as batch A and batch B, with porosities of approximately 60 and 80%, respectively, were selected for this study and implanted for periods of 5, 13, and 26 weeks into the lower femur of New Zealand White rabbits. Histomorphometric analysis of the absolute volume of bone ingrowth within batch A and B implants from 5 to 26 weeks showed that the absolute volume of bone ingrowth was consistently lower in batch A (10-21%), compared to batch B implants (24-31%). However, when the volume of bone ingrowth was normalised for the available pore space, this ...

2004-01-01

161

Estimates of Amplitudes of Transient Regimes in Quasi-Controllable Discrete Systems  

CERN Document Server

Families of regimes for discrete control systems are studied possessing a special quasi-controllability property that is similar to the Kalman controllability property. A new approach is proposed to estimate the amplitudes of transient regimes in quasi-controllable systems. Its essence is in obtaining of constructive a priori bounds for degree of overshooting in terms of the quasi-controllability measure. The results are applicable for analysis of transients, classical absolute stability problem and, especially, for stability problem for desynchronized (asynchronous, switching) systems.

2009-01-01

162

Determination of the performance of explosives  

Energy Technology Data Exchange (ETDEWEB)

The author attempts to calculate the absolute characteristics of explosives unrelated to the effects of environment, particularly for that part of the work of the explosion done by the expansion of the detonation products. Setting forth his equations and noting their agreement with experimental data, he concludes that for a complete characterization of the relative effectiveness of explosives it is necessary to know the pressure, mass velocity, and polytropic index of the detonation products, but that developed considerations of the relation between performance and detonation characteristics permit a more exact evaluation of various explosives and unification of the nomenclature of explosives and methods of testing them.

1984-11-01

163

Biological effects and health risks following to the exposition to ionizing radiation  

International Nuclear Information System (INIS)

Late somatic and genetic radiation effects are imperfectly understood, particularly in the human species. However the available information is sufficient to draw reasonably precise risk estimates in man for many types of damage by means of scientifically justifiable procedures and with the necessary caution. This overall absolute risk of major somatic and genetic damage may be set at around 10"-"4/rad of chronic whole-body doses.

1976-01-01

164

A study of the Baldwin effect in the IUE data set  

Science.gov (United States)

The paper investigates the controversial relation between the continuum luminosity and the C IV 1550 emission-line strength in the spectra of quasars, commonly referred to as the Baldwin effect, as a possible indicator of absolute luminosity. It is concluded that the Baldwin effect does represent a physical correlation between the continuum and the C IV 1550 equivalent width rather than a consequence of selection effects. In addition to the C IV results, a similar relation is found for the Lyman-alpha emission line. 38 refs.

1990-07-01

165

A nonlinear model for DNA dynamics  

Science.gov (United States)

In this paper the thermal equilibrium number of solitons in DNA as a function of absolute temperature and the number of base pairs is calculated. These calculations are effected by modeling DNA as a Toda lattice with parameters chosen to match experimentally measured properties of DNA. It is found that a significant number of solitons is generated at physiological temperature. 23 refs., 2 figs.

1989-07-01

166

The EPA (Environmental Protection Agency) low-level waste standard-a status report  

Energy Technology Data Exchange (ETDEWEB)

The Environmental Protection Agency (EPA) is developing generally applicable environmental standards for land disposal of Atomic Energy Act (AEA) low-level radioactive wastes (LLW) and certain naturally occurring and accelerator-produced radioactive material (NARM) wastes. It is EPA's intention that the LLW standards will protect public health and the environment. The LLW standards would cover disposal of all AEA materials not controlled by other EPA standards and some natural radioactive materials. Coverage of federal waste is significant, because the federal government generates and disposes of >40% of all LLW nationwide, and a uniform standard for all LLW disposal is both a desirable and an achievable goal. Publication of a proposed LLW standard is planned in 1988, and a final standard a year later. This ...

1988-01-01

167

The use of calcium silicate bricks for retrospective dosimetry  

International Nuclear Information System (INIS)

The suitability of calcium silicate bricks (CSBs) for the retrospective measurement of gamma dose using luminescence techniques has been investigated. Bricks of this type are distinguished from fired clay bricks by containing negligible clay and requiring comparatively low temperature treatment during manufacture. They have been used widely in the construction f buildings in the Former Soviet Union since the 1970s but hitherto have not been used for retrospective dosimetry measurements. A procedure based on the se of the 210 deg. C thermoluminescence (TL) peak of quartz was tested with granular quartz extracted from three types of CSB, one of which had been taken from a settlement downwind of Chernobyl. The degree to which the residual geological TL signal within the temperature range of the 210 deg. C L peak had been reduced during manufacture varied with brick type; the levels of residual TL corresponded, in the samples tested, to absorbed doses n the range ...

2004-02-01

168

Performance evaluation of the conventional Brazilian industries radiation protection in the small industrial gauges and industrial radiography areas; Sistema de avaliacao de desempenho em radioprotecao das industrias convencionais brasileiras nas areas de medidores nucleares e radiografia industrial  

Energy Technology Data Exchange (ETDEWEB)

This works evaluates by punctuation the performance in conventional Brazilian industries radiation protection area which make use of small industrial gauges and industrial radiography. It proposes, procedures for industry self-evaluation, besides a new radiation protection plans pattern for the small industrial gauges area. The data source where inspection reports of Dosimetry Radiation Protection Institute/Nuclear Energy Commission conventional Brazilian industries' radiation protection plans, beyond visitation to the inspection place. The performance evaluation has been realized both in the administrative and operational aspects of the industries. About of 60% of the industries have a satisfactory register control which does not happen to the operational control. The performance evaluation advantage is that industries may self-evaluate, foreseeing Dosimetry Radiation Protection Institute's regulation inspections, correcting ...

1999-08-01

169

Measurements and elimination of Cherenkov light in fiber-optic scintillating detector for electron beam therapy dosimetry  

International Nuclear Information System (INIS)

In this study, a miniature fiber-optic radiation detector has been developed using a water-equivalent organic scintillator for electron beam therapy dosimetry. Usually, two kinds of light signals such as fluorescent and Cherenkov lights are generated in a fiber-optic radiation detector when a high-energy electron beam is irradiated. The fluorescent light signal is produced in the scintillator and is transmitted through a plastic optical fiber to a remote light-measuring device such as a PMT or a photodiode. The Cherenkov light could be also produced in the plastic optical fiber itself and be detected by a light-measuring device. Therefore, it could cause problems or limit the accuracy of the detection of a fluorescent light signal that is proportional to dose. The objectives of this study are to measure, characterize and eliminate Cherenkov light generated in a plastic optical fiber used as a component of a fiber-optic radiation detector and to detect a real ...

2007-08-21

170

ESR dosimetry of irradiated chicken legs and chicken eggs  

Energy Technology Data Exchange (ETDEWEB)

Ionising radiation induces stable free radicals in chicken bones and in the shell of chicken eggs which can be detected, by the electrons spin resonance (ESR) technique, well beyond the shelf-life of the food and can be used for dosimetry. The method usually adopted to evaluate ``a posteriori`` the dose given during the ionising radiation treatment of food, is the dose additive method. To assess the dose, the ESR signal amplitude of the irradiated food (bone or egg shell in the present case) is measured and then the dose-effect relationship is obtained by re-irradiating the sample with some additive doses (usually of 1 kGy). The dose-effect curve is back-extrapolated and the initial given dose determined. At the Istituto Superiore di Sanita (ISS), Rome, Italy, a research programme was approved two years ago aimed to, (1) study new methodological approaches for ESR dose assessment, and (2) analyse the factors which may influence the ESR readout of irradiated chicken ...

1996-12-31

171

Analysis of radioactivity levels in the surrounding of the Aube storage plant (F.M.A.-V.C.). year 2007. Presentation, results and methods; Analyse des niveaux de la radioactivite dans les environs du centre de stockage F.M.A.-V.C. de l'Aube. Annee 2007. Presentation, resultats et methodes  

Energy Technology Data Exchange (ETDEWEB)

The study had three objectives: to collect information that explain the impact of the Aube storage center (C.S.A.) on environment and allow to evaluate the consequences for man, secondly, to build a referential for any future inquiry or follow-up, thirdly, to allow to the local commission of information to elaborate an information towards the side residents and local actors that take into account their questions. Trees, waters, sediments, soils, grass, products of gardens and vineyards were the object of sampling, their dosimetry is given in this report. Other dosimetry measures were made along the nuclear site and the results are equally in this report. (N.C.)

2007-07-01

172

sup 131 I treatment of thyroid papillary carcinoma in a patient with renal failure  

Energy Technology Data Exchange (ETDEWEB)

Procedures for {sup 131}I ablation in renal failure are not known. In one patient receiving dialysis, detailed dosimetry and health safety aspects were obtained. The results showed insignificant contamination of equipment, but a surprisingly significant reduction in biologic half-life of {sup 131}I due to efficient dialysis extraction. The data indicate that {sup 131}I ablation can be done safely and easily during dialysis but that much higher {sup 131}I doses must be used to achieve equivalent results to those obtained in patients with normal renal function.

1990-12-15

173

Review of electron beam therapy physics  

Energy Technology Data Exchange (ETDEWEB)

For over 50 years, electron beams have been an important modality for providing an accurate dose of radiation to superficial cancers and disease and for limiting the dose to underlying normal tissues and structures. This review looks at many of the important contributions of physics and dosimetry to the development and utilization of electron beam therapy, including electron treatment machines, dose specification and calibration, dose measurement, electron transport calculations, treatment and treatment-planning tools, and clinical utilization, including special procedures. Also, future changes in the practice of electron therapy resulting from challenges to its utilization and from potential future technology are discussed. (review)

2006-07-07

174

Organ doses and integral doses in X-ray diagnosis of the chest and of the head  

International Nuclear Information System (INIS)

Organ and tissue doses and integral doses in patients due to diagnostic x-ray examinations of the chest and of the head will be presented. These data have been obtained by measuring the dose distributions in man phantoms by LiF-dosimetry. The data will be compared with data obtained by Monte-Carlo calculations. To obtain average organ doses for a special type of examination for the population or for a specified subpopulation in the variation of the exposure, data due to the different techniques used by the different radiologists has to be known. Such data will be presented. The results of the investigation will be discussed in connection with the concept of the 'somatic significant.

1977-04-01

175

Nuclear forensics  

International Nuclear Information System (INIS)

Nuclear forensics is the analysis of nuclear materials recovered from either the capture of unused materials, or from the radioactive debris following a nuclear explosion and can contribute significantly to the identification of the sources of the materials and the industrial processes used to obtain them. In the case of an explosion, nuclear forensics can also reconstruct key features of the nuclear device. Nuclear forensic analysis works best in conjunction with other law enforcement, radiological protection dosimetry, traditional forensics, and intelligence work to provide the basis for attributing the materials and/or nuclear device to its originators. Nuclear forensics is a piece of the overall attribution process, not a stand-alone activity

2010-02-01

176

Luminescence characteristics of LiCaAlF6:Eu phosphor  

British Library Electronic Table of Contents (United Kingdom)

A simple method for preparing LiCaAlF6:Eu2+ phosphor is reported. Photoluminescence (PL) and thermoluminescence (TL) studies were carried out. The TL sensitivity of the phosphor is nearly twice that of CaSO4:Dy TLD phosphor. Several other properties required for TL dosimetry are superior as well. It is suggested that the phosphor can be a suitable replacement for CaSO4:Dy. (Copyright 2007 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim)

2007-01-01

177

Interest of a two-dimensional matrix of detectors for the quality control of beams in static or dynamic mode; Interet d'une matrice bidimensionnelle de detecteurs pour le controle de qualite des faisceaux en mode statique ou dynamique  

Energy Technology Data Exchange (ETDEWEB)

A 2D matrix allows a fairly rapid verification of irradiation parameters transferred on computer processing equipment without expanding the dosimetry means to implement. Associated to 'Multicheck and Verisoft' software it will handle some of the regulatory recommendations of the A.F.S.S.A.P.S. for quality control of accelerators and ensure the traceability of testing carried out. (N.C.)

2007-11-15

178

INEEL BNCT research program. Annual report, January 1, 1996--December 31, 1996  

Energy Technology Data Exchange (ETDEWEB)

This report is a summary of the progress and research produced for the Idaho National Engineering and Environmental Laboratory (INEEL) Boron Neutron Capture Therapy (BNCT) Research Program for calendar year 1996. Contributions from the individual investigators about their projects are included, specifically, physics: treatment planning software, real-time neutron beam measurement dosimetry, measurement of the Finnish research reactor epithermal neutron spectrum, BNCT accelerator technology; and chemistry: analysis of biological samples and preparation of {sup 10}B enriched decaborane.

1997-04-01

179

INEEL Advanced Radiotherapy Research Program Annual Report 2001  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the major activities and accomplishments of the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2001. Applications of supportive research and development, as well as technology deployment in the fields of chemistry, radiation physics and dosimetry, and neutron source design and demonstration are described. Contributions in the fields of physics and biophysics include development of advanced patient treatment planning software, feasibility studies of accelerator neutron source technology for Neutron Capture Therapy (NCT), and completion of major modifications to the research reactor at Washington State University to produce an epithermal-neutron beam for NCT research applications.

2002-04-01

180

INEEL Advanced Radiotherapy Research Program Annual Report 2001  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the major activities and accomplishments of the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2001. Applications of supportive research and development, as well as technology deployment in the fields of chemistry, radiation physics and dosimetry, and neutron source design and demonstration are described. Contributions in the fields of physics and biophysics include development of advanced patient treatment planning software, feasibility studies of accelerator neutron source technology for Neutron Capture Therapy (NCT), and completion of major modifications to the research reactor at Washington State University to produce an epithermal-neutron beam for NCT research applications.

2002-04-30

181

Algorithm for assessment of mean annual gonad dose and genetically significant dose from the data of personal dosimetry  

International Nuclear Information System (INIS)

During one year more than 40,000 items of information on radiation exposure of personnel involved in the handling of radiation sources and more than 5,000,000 items on irradiation of other people are collected in the authors' laboratory. Considerable progress in assessment of mean annual gonad dose of genetically sifnificant dose was attained by means of an algorithm for a personal computer. This simple and inexpensive system has led to a higher accuracy in the application of protective measures. (author).

1985-10-22

182

Vector Boson Scattering in the Standard Model an Overview of Formulae  

CERN Document Server

Tree-level scattering amplitudes of longitudinally polarized electroweak vector bosons in the Standard Model are calculated using Mathematica package Feyncalc. The modifications of low-energy theorems for longitudinally polarized W and Z in the Standard Model are discussed.

1997-01-01

183

System 80+{trademark} standard design: CESSAR design certification. Volume 15: Amendment I  

Energy Technology Data Exchange (ETDEWEB)

This report has been prepared in support of the industry effort to standardize nuclear plant designs. These documents describe the Combustion Engineering, Inc. System 80+{trademark} Standard Design.

1990-12-21

184

System 80+trademark standard design: CESSAR design certification  

International Nuclear Information System (INIS)

This report has been prepared in support of the industry effort to standardize nuclear plant designs. These documents describe the Combustion Engineering, Inc. System 80+trademark Standard Design.

185

Clinical pathology accreditation: standards for the medical laboratory  

UK PubMed Central (United Kingdom)

This article describes a new set of revised standards for the medical laboratory, which have been produced by Clinical Pathology Accreditation (UK) Ltd (CPA). The original standards have been in use...Full Text Available

2002-10-01

186

Benzene Enabling Document for Standards on Benzene Transfer and Waste Operations.  

Science.gov (United States)

On February 27, 1990, standards for Benzene were promulgated for benzene transfer and benzene waste operations. The benzene enabling document summarizes these standards. The basic purpose of the document is to assist the EPA regional enforcement personnel...

1990-01-01

187

Abnormalities in the microsomal oxidases of the WHO standard reference strain of Musca domestica*  

UK PubMed Central (United Kingdom)

Observations made during biochemical and toxicological studies of the housefly, in which the WHO standard reference (SR) strain was used as a standard, indicated that this strain differs from other...Full Text Available

1975-01-01

188

45 CFR 170.210 - Standards for health information technology to protect electronic health information created...  

Science.gov (United States)

...2010-10-01 false Standards for health information technology to protect electronic health information...DEPARTMENT OF HEALTH AND HUMAN SERVICES HEALTH INFORMATION TECHNOLOGY HEALTH INFORMATION TECHNOLOGY STANDARDS, IMPLEMENTATION...

2010-10-01

189

Video equipment of tele dosimetry and audio  

International Nuclear Information System (INIS)

To develop a work in an area with high radiation, it requires of a detailed knowledge of the surroundings work, a communication and effective vision, a near dosimetric control. In a work where the spaces variables and reduced accesses exist, noise that hinders the communication, defendant operative condition, radiation field and taking of decision, it is necessary to have tools that allow a total control of the environment to make opportune and effective decisions, there where the task is developed. Under this elementary concept, it was developed in the Laguna Verde Central a project that it allowed a mechanism, interactive of control in spaces complex; to see, to hear, to speak, to measure. This concept takes to the creation of an equipped system with closed circuit of television, wireless communication systems, tele dosimetry wireless systems, VHS and DVD recording equipment, uninterrupted energy units. The system requires of an electric power socket, and the ...

2007-07-01

190

Particokinetics In Vitro: Dosimetry Considerations for In Vitro Nanoparticle Toxicity Assessments  

Energy Technology Data Exchange (ETDEWEB)

The rapid growth in the use of in vitro methods for nanoparticle toxicity assessment has proceeded with limited consideration of the unique kinetics of these materials in solution. Particles in general and nanoparticles specifically, diffuse, settle and agglomerate in cell culture media as a function of several systemic and particle factors: media density and viscosity, particle size, shape and density. Cellular dose then is also a function of these factors as they determine the rate of transport of nanoparticles to cells in culture. Here we develop and apply the principles of particokinetics and dosimetry in vitro and outline an approach for simulation of nanoparticle particokinetics in cell culture systems. We illustrate that where equal mass concentrations (?g/ml) imply equal doses for dissimilar materials, the corresponding particle number or surface area concentration doses differ by orders of magnitude. When rates of diffusional and gravitational particle ...

2007-02-01

191

Use of gold and silver standards based on phenol-formalde-hyde resin in assay-activation analysis of geological samples  

International Nuclear Information System (INIS)

Using standards on phenol-formaldehyde resin base for assaying-activation analysis of geological specimens for gold and silver has bee the advantage of uniformly distributing Au and Ag in spesimens and possible preparing tablets of practically any form or size. The validity and accuracy of these standards have been studied for the cases of short irradiation. Conventional point standards were used as reference standards. The experiments carried out have shown that tablet resol standards are suitable for a mass assaying-activation analysis for gold and silver at practically any concentrations.

192

Standardization/improvement and technical development of light water reactor power station in Japan(BWR)  

Energy Technology Data Exchange (ETDEWEB)

In order to realize improve of reliability and economy by duplicate production, rapid supply of repair parts from standardized storage, such were expected as to have continuous order of standardized plant, to ignore site condition, to avoid expansion of regulatory requirement. Standardization program was planned to limitedly promote standardization of safety-related design concept, major specification and basic system composition of reactor and primary systems. The area of standardization had been tried to expand to BOP such as general arrangement and rad-waste system.

1985-07-01

193

Development of an analysis rule of diagnosis error for standard method of human reliability analysis  

International Nuclear Information System (INIS)

This paper presents the status of development of Korea standard method for Human Reliability Analysis (HRA), and proposed a standard procedure and rules for the evaluation of diagnosis error probability. The quality of KSNP HRA was evaluated using the requirement of ASME PRA standard guideline, and the design requirement for the standard HRA method was defined. Analysis procedure and rules, developed so far, to analyze diagnosis error probability was suggested as a part of the standard method. And also a study of comprehensive application was performed to evaluate the suitability of the proposed rules.

2003-10-01

194

The Effects of Long Term Storage on Special Purpose Lead ...  

Science.gov (United States)

... Special Purpse Lead Azide Lot #I3A-4-62 ... Standard X-ray techniques are not sufficiently sensitive ... the National Bureau of Standards, and examined ...

1972-10-01

195

The Economic Strategy for German Unification  

Science.gov (United States)

... PERSONAL AUTHOR(S) ROY A. BROOKS, LTC i3a. ... gave the impression of an immediate increase in the standard ... high rate by German standards. ...

1993-02-19

196

The Development of a Dental Diagnostic Terminology  

UK PubMed Central (United Kingdom)

There is no commonly accepted standardized terminology for oral diagnoses. The purpose of this article is to report the development of a standardized dental diagnostic terminology by a work...Full Text Available

2011-01-01

197

STUDY OF METEOR WIND MEASUREMENT TECHNIQUES. ...  

Science.gov (United States)

... of a secondary standard (VCO) locally available. ... phase of the local secondary standards to the 10-min average of the phase of ... I3a - - \\.-e-~--. ...

1970-02-01

198

Interim radiological safety standards and evaluation procedures for subseabed high-level waste disposal  

Energy Technology Data Exchange (ETDEWEB)

The Seabed Disposal Project (SDP) was evaluating the technical feasibility of high-level nuclear waste disposal in deep ocean sediments. Working standards were needed for risk assessments, evaluation of alternative designs, sensitivity studies, and conceptual design guidelines. This report completes a three part program to develop radiological standards for the feasibility phase of the SDP. The characteristics of subseabed disposal and how they affect the selection of standards are discussed. General radiological protection standards are reviewed, along with some new methods, and a systematic approach to developing standards is presented. The selected interim radiological standards for the SDP and the reasons for their selection are given. These standards have no legal or regulatory status and will be replaced or modified by regulatory ...

1997-06-01

199

Impacts of Renewable Fuel and Electricity Standards on State Economies (Poster)  

Energy Technology Data Exchange (ETDEWEB)

This poster, submitted for the CU Energy Initiative/NREL Symposium on October 3, discusses the impacts of renewable fuel and electricity standards on state economies.

2006-10-03

200

Development of standard solutions for the Minergie standard; Standardloesungen - Entwicklung von Standardloesungen fuer den Minergie-Standard  

Energy Technology Data Exchange (ETDEWEB)

This final report for the Swiss Federal Office of Energy (SFOE) examines a project that aimed to define standard solutions for use in buildings built to meet Minergie low energy consumption standards. These standard solutions are to provide a way of meeting Minergie standards in an easy way and thus further the use of the standard and also assure quality at the same time. The report describes how the solutions were developed on the basis of a selection of existing Minergie buildings. For various combinations of heating systems - wood, wood/solar, heat pumps (brine-water and air-water), gas/solar and oil/solar - the appropriate U-values for various building elements are listed. The resulting Minergie forms and guides are listed.

2003-07-01

201

An Evaluation of a Technique for Using the Combat Training ...  

Science.gov (United States)

... proficiency, most Army personnel must shoot to the same standards required of ... Wild- flecken was to provide this standard range, but its scores ... I3a I] ...

1979-05-01

202

A PC-Based Imaging System for the Naval Postgraduate ...  

Science.gov (United States)

... 1 I3a TYPE OF REPORT 1 3b TIME COVERED ... Measured by this standard the system provides good results; it ... did not fully meet all the standards or ...

1989-09-01

203

50 (Fifty) Years of Research on Man in Flight  

Science.gov (United States)

... i3a. ... This pioneering research established the new Air Force standard for future ... Echols ,.stablished new standards for high- altitude long-range flight ...

1985-06-01

204

Comparison of the Standards applied to Instrumentation and Control Systems for Nuclear Power Stations in Korea and Russia  

Energy Technology Data Exchange (ETDEWEB)

This report describes a comparison result of technical standards applied to instrumentation and control systems for nuclear power plants between in Korea and in Russia. Russia also has a state-run organization authorized to conduct approval, cancellation, and audit in use of nuclear facility or equipment. The Russian standards for nuclear instrumentation and control equipment are analogous with the Korean ones in the aspect of basic concepts and principles. However, there are some differences in document structure, design requirements, qualification test items, depth of contents between two standard systems. The biggest deviation exists in the standard documents for seismic qualification and electromagnetic interference qualification. Korean seismic qualification standard utilizing US approach, defines testing and qualification methods specifically and clearly. Russian ...

2005-04-15

205

Tuning PID and FOPID Controllers using the Integral Time Absolute Error Criterion  

CERN Document Server

Particle swarm optimization (PSO) is extensively used for real parameter optimization in diverse fields of study. This paper describes an application of PSO to the problem of designing a fractional-order proportional-integral-derivative (FOPID) controller whose parameters comprise proportionality constant, integral constant, derivative constant, integral order (lambda) and derivative order (delta). The presence of five optimizable parameters makes the task of designing a FOPID controller more challenging than conventional PID controller design. Our design method focuses on minimizing the Integral Time Absolute Error (ITAE) criterion. The digital realization of the deigned system utilizes the Tustin operator-based continued fraction expansion scheme. We carry out a simulation that illustrates the effectiveness of the proposed approach especially for realizing fractional-order plants. This paper also attempts to study the behavior of fractional PID controller ...

2008-01-01

206

Thermal stability of carboxylic acid functionality in coal; Sekitanchu ni sonzaisuru karubokishiruki no netsubunkai kyodo  

Energy Technology Data Exchange (ETDEWEB)

Carboxyl in coal was focused in discussing its pyrolytic behavior while tracking change of its absolute amount relative to the heating temperatures. A total of four kinds of coals, consisting of two kinds brown coals, sub-bituminous coal and bituminous coal were used. Change in the absolute amount of carboxyl due to heating varies with coalification degree. Decomposition starts in the bituminous coal from around 300{degree}C, and is rapidly accelerated when 400{degree}C is exceeded. Carboxyls in brown coals exist two to three times as much as those in bituminous and sub-bituminous coals, of which 40% is decomposed at a temperature as low as about 300{degree}C. Their pyrolytic behavior at temperatures higher than 400{degree}C resembles that of the bituminous coal. Carboxyls consist of those easy to decompose and difficult to decompose. Aromatic and aliphatic carboxylic acids with simple structure are stable at temperatures lower than ...

1996-10-28

207

The composite absolute penalties family for grouped and hierarchical variable selection  

CERN Document Server

Extracting useful information from high-dimensional data is an important focus of today's statistical research and practice. Penalized loss function minimization has been shown to be effective for this task both theoretically and empirically. With the virtues of both regularization and sparsity, the $L_1$-penalized squared error minimization method Lasso has been popular in regression models and beyond. In this paper, we combine different norms including $L_1$ to form an intelligent penalty in order to add side information to the fitting of a regression or classification model to obtain reasonable estimates. Specifically, we introduce the Composite Absolute Penalties (CAP) family, which allows given grouping and hierarchical relationships between the predictors to be expressed. CAP penalties are built by defining groups and combining the properties of norm penalties at the across-group and within-group levels. Grouped selection occurs for nonoverlapping groups. ...

2009-01-01

208

Stability study of a gyrotron-traveling-wave amplifier based on a lossy dielectric-loaded mode-selective circuit  

Science.gov (United States)

The millimeter microwave source of gyrotron-traveling-wave amplifier (gyro-TWT) is capable of generating high power coherent radiation in a broad bandwidth, while its performance is severely deteriorated by the stability problems. This paper focuses on modeling and the stability analysis of the Naval Research Laboratory (NRL) Ka-band TE{sub 01} mode gyro-TWT based on an interaction circuit alternately loaded with lossy ceramic shells and metal rings. The propagation characteristics of the interaction circuit is analyzed first, based on which the boundary impedance method is employed to build an equivalent uniform lossy circuit. Then the stability of the interaction system is studied using linear and nonlinear theories. The analysis reveals that, due to the special waveguide structure and the dielectric loss, the propagation characteristics of the complex waveguide are similar to that of a uniform lossy circuit. The analysis of the absolute instabilities ...

2009-07-15

209

Stability study of a gyrotron-traveling-wave amplifier based on a lossy dielectric-loaded mode-selective circuit  

International Nuclear Information System (INIS)

The millimeter microwave source of gyrotron-traveling-wave amplifier (gyro-TWT) is capable of generating high power coherent radiation in a broad bandwidth, while its performance is severely deteriorated by the stability problems. This paper focuses on modeling and the stability analysis of the Naval Research Laboratory (NRL) Ka-band TE01 mode gyro-TWT based on an interaction circuit alternately loaded with lossy ceramic shells and metal rings. The propagation characteristics of the interaction circuit is analyzed first, based on which the boundary impedance method is employed to build an equivalent uniform lossy circuit. Then the stability of the interaction system is studied using linear and nonlinear theories. The analysis reveals that, due to the special waveguide structure and the dielectric loss, the propagation characteristics of the complex waveguide are similar to that of a uniform lossy circuit. The analysis of the absolute instabilities characterizes the ...

2009-07-01

210

Rotating magnetic tensor gradiometry and a superconducting implementation  

International Nuclear Information System (INIS)

This work describes the theoretical basis for a new concept rotating magnetic tensor gradiometer. The rotating gradiometer consists of an approximately axial or transverse gradiometer which is made to rotate about a perpendicular axis so that the direction of sensitivity is continually changing. It is demonstrated for the first time that the rotation separates gradient components of progressively higher-order in the frequency domain and enables absolute-value measurements of all components of the first-order magnetic gradient tensor, even if the magnetic sensors comprising the gradiometer are intrinsically incapable of absolute-value detection. In addition, the rotating gradiometer concept has a number of other advantages: the gradiometer imbalance is no longer directly determined by the engineering precision, the DC and low-frequency performance of the instrument is not limited by the performance of the detectors in these respects, rotation at ...

2009-07-01

211

Effects of relativity and 'atomic structure' in the KLL Auger spectrum of "8"8Sr generated in the EC-decay of "8"8Y  

International Nuclear Information System (INIS)

The KLL Auger electron spectrum of "8"8Sr generated in the EC-decay of "8"8Y has been analyzed at the instrumental resolution of 11 eV using a combined electrostatic spectrometer. Energies and relative intensities of the all nine transitions were determined and compared with theoretical predictions. Our value of 12067.3(12) eV measured for the absolute energy of the dominant KL_2L_3("1D_2) transition was found to be higher by 7.4 eV (i.e., more than 3#sigma#) than that one obtained in a measurement with external excitation. The discrepancy indicates substantial influence of the 'atomic structure effect' on absolute transition energies in our experiment. Very good agreement of the measured 0.14(3) and predicted 0.12 values for the KL_1L_2("3P_0/"1P_1) Auger transition intensity ratio clearly proved the predicted strong influence of the relativistic effects on the KL_1L_2("3P_0) transition rate even at Z = 38.

2007-08-01

212

Are there alternative insurance coverage models to enhance financial security for nuclear liability?; Alternative Deckungsmodelle fuer die Nuklearhaftpflicht?  

Energy Technology Data Exchange (ETDEWEB)

The proposed ERICAM model exhibits deficiencies of a nature making it inacceptable to responsible governments. These deficiencies are: it does not provide the required financial security. The availability of insurance coverage will be dependent on the situation in the financial markets. Pricing will not be determined by the absolute probability of incidents causing damage, so that this may entail a distortion of allocations of resources. (orig./HP) [Deutsch] Das ERICAM Modell hat Konstruktionsmaengel, dass es sicher fuer verantwortliche Regierungen nicht in Frage kaeme, dessen Realisierung in Erwaegung zu ziehen. Die wichtigsten sind: Die benoetigte Sicherheit der Deckungsmittel ist nicht gegeben. Die Lage an den Finanzmaerkten dominiert die Verfuegbarkeit der Deckungsmittel. Die Preisbildung wird nicht durch die absolute Schadenswahrscheinlichkeit bestimmt, so dass eine Verfaelschung der Allokation von Ressourcen eintreten wuerde. (orig./HP)

1995-12-31

213

Absolute spacetime the twentieth century ether  

CERN Document Server

All gauge theories need ``something fixed'' even as ``something changes.'' Underlying the implementation of these ideas all major physical theories make indispensable use of an elaborately designed spacetime model as the ``something fixed,'' i.e., absolute. This model must provide at least the following sequence of structures: point set, topological space, smooth manifold, geometric manifold, base for various bundles. The ``fine structure'' of spacetime inherent in this sequence is of course empirically unobservable directly, certainly when quantum mechanics is taken into account. This issue is at the basis of the difficulties in quantizing general relativity and has been approached in many different ways. Here we review an approach taking into account the non-Boolean properties of quantum logic when forming a spacetime model. Finally, we recall how the fundamental gauge of diffeomorphisms (the issue of general covariance vs coordinate conditions) raised deep ...

1999-01-01

214

Absolute differential cross sections for the scattering of kilo-electron-volt O atoms  

International Nuclear Information System (INIS)

This paper reports measurements of absolute differential cross sections for the direct scattering of oxygen atoms by He, Ne, Ar, Kr, Xe, H_2, N_2, O_2, CO, CO_2, H_2O, SO_2, NH_3, CH_4, CF_4, and SF_6 targets. The measured cross sections include contributions from all elastic and inelastic processes that result in a fast neutral oxygen atom product. Cross sections are presented for 0.5- and 1.5-keV projectile energies over the laboratory angular range 0.2 degree endash 5 degree. When compared in the center-of-mass reference frame, these cross sections exhibit a high degree of similarity in both amplitude and angular dependence. The cross sections for N_2, CO, CO_2, and H_2O are inverted using a partial-wave analysis to yield empirical interaction potentials, which can then be used to extrapolate the measurements down to lower energies. Using these potentials, cross sections are evaluated at 0.1 keV. copyright 1996 The American Physical Society.

215

Absolute cross sections for near-threshold electron-impact excitation of the 2s"2S#->#2p"2P transition in C"3"+  

International Nuclear Information System (INIS)

Absolute total cross sections for electron-impact excitation of the 2s"2S#->#2p"2P transition in C"3"+ were measured from 7.35 eV to 8.45 eV using the merged electron-ion-beams energy-loss technique. The results settle the discrepancy between two previous experiments using the crossed-beams fluorescence method, being in very good agreement with the older results [P. O. Taylor, D. Gregory, G. H. Dunn, R. A. Phaneuf, and D. H. Crandall, Phys. Rev. Lett. 39, 1256 (1977)] but less so with the more recent ones [D. W. Savin, L. D. Gardner, D. B. Reisenfeld, A. R. Young, and J. L. Kohl, Phys. Rev. A 51, 2162 (1995)]. The present measurements are also in good agreement with unitarized Coulomb-Born and close-coupling calculations. copyright 1998 The American Physical Society.

216

Simple integral screenprinting process for selective emitter polycrystalline silicon solar cells  

Energy Technology Data Exchange (ETDEWEB)

This letter describes a new simple fabrication process, developed recently for blue response'' improvement in low-cost polycrystalline silicon solar cells. A selective emitter is created by heavily doping the emitter, followed by a wet etching-back of the cell area between the fingers. An improvement up to 17 mV in {ital V}{sub oc}, 1.5 mA/cm{sup 2} in {ital J}{sub sc}, and 1% (absolute value) in {eta} is obtained. Effective phosphorus gettering, self-alignment, and application in a low-cost full screenprinting technology are the main advantages of the proposed process.

1991-09-23

217

Redox potential measurement in the power station  

Energy Technology Data Exchange (ETDEWEB)

By its very nature redox potential measurement is suitable for determining the concentration ratio of a stable redox pair through its interaction with a chemically inert electrode surface but not the absolute concentration of a material. The measured redox potentials agree only rarely with those which are easily calculable theoretically. No individual defined stable redox pair is available in power station water. It is therefore not simply possible to measure definable mixed potentials more precisely. For these reasons redox potential measurement in the power station, as also with other types of water, can no longer be regarded as an indicator, by which it can be established whether oxidizing or reducing materials predominate in the water.

1983-01-01

218

Redox potential measurement in the power station  

International Nuclear Information System (INIS)

By its very nature redox potential measurement is suitable for determining the concentration ratio of a stable redox pair through its interaction with a chemically inert electrode surface but not the absolute concentration of a material. The measured redox potentials agree only rarely with those which are easily calculable theoretically. No individual defined stable redox pair is available in power station water. It is therefore not simply possible to measure definable mixed potentials more precisely. For these reasons redox potential measurement in the power station, as also with other types of water, can no longer be regarded as an indicator, by which it can be established whether oxidizing or reducing materials predominate in the water. (orig.).

219

Procyon 1. First prototype worldwide for storage spent nuclear fuel rods  

International Nuclear Information System (INIS)

HFH Herbst has designed and built a unique machine for storage of spent highly radioactive nuclear fuel rods within two years for the Swedish SKB. The vehicle (total weight 98 t) can be operated underground without a driver. Herbst was able to bring to this project almost 30 years of experience in the complementation of vehicle projects for the nuclear industry. The Procyon 1 already proved its efficiency impressively in several hundred storage processes and operates with absolute reliability. (orig.)

2010-05-01

220

Preparation of flame resistant fibers from polyacrylonitrile fibers  

Energy Technology Data Exchange (ETDEWEB)

In this article, a continuous stabilization process was used to make flame resistant fibers from polyacrylonitrile (PAN) fibers. The effect of the stabilization time and the stretching process during the stabilization process on the physical properties and flammability of the resultant flame resistant fibers was studied. Increased drawing of PAN fibers during the continuous stabilization process was found to decrease the diameter and increase the tensile strength in the resultant flame resistant fibers. These fibers also had higher density. There were no absolute relationships seen between flame-resistance and the formation of stable ladder polymers, density, and oxygen content. ((orig.))

1994-07-27

221

Plasma flow measurement using directional Langmuir probe under weakly ion-magnetized conditions  

Energy Technology Data Exchange (ETDEWEB)

It is both experimentally and theoretically demonstrated that ion flow velocity at an arbitrary angle with respect to the magnetic field can be measured with a directional Langmuir probe. Based on the symmetry argument, we show that the effect of magnetic field on directional probe current is exactly canceled in determining the ion flow velocity, and obtain the generalized relation between flow velocity and directional probe currents valid for any flowing direction. The absolute value of the flow velocity is determined by an in situ calibration method of the probe. The applicability limit of the present method to a strongly ion-magnetized plasma is experimentally examined. (author)

2000-07-01

222

One-electron oxidation of photosynthetic pigments in micelles. Bacteriochlorophyll a, chlorophyll a, chlorophyll b, and pheophytin a  

International Nuclear Information System (INIS)

Chlorophyll a, chlorophyll b, and bacteriochlorophyll a in aqueous micellar solutions of Trition X 100 (2%) are readily oxidized by pulse-radiolytically generated N_3., Br_2"-., and (SCN)_2"-. radicals at nearly diffusion-controlled rates. The kinetic study suggests that pigment molecules occupy multiple sites in the micelle. Pheophytin a is only oxidized by N_3. and Br_2"-. radicals. The absolute spectra and the molar extinction coefficients of chlorophyll a, bacteriochlorophyll a, chlorophyll b, and pheophytin a cations have been determined. The chlorophyll a cation has been observed in the presence of pigment aggregates.

1981-11-01

223

Nuclear charge radii of light isotopes based on frequency comb measurements  

Energy Technology Data Exchange (ETDEWEB)

Optical frequency comb technology has been used in this work for the first time to investigate the nuclear structure of light radioactive isotopes. Therefore, three laser systems were stabilized with different techniques to accurately known optical frequencies and used in two specialized experiments. Absolute transition frequency measurements of lithium and beryllium isotopes were performed with accuracy on the order of 10{sup -10}. Such a high accuracy is required for the light elements since the nuclear volume effect has only a 10{sup -9} contribution to the total transition frequency. For beryllium, the isotope shift was determined with an accuracy that is sufficient to extract information about the proton distribution inside the nucleus. A Doppler-free two-photon spectroscopy on the stable lithium isotopes {sup 6,7}Li was performed in order to determine the absolute frequency of the 2S {yields} 3S transition. The achieved relative accuracy ...

2010-02-11

224

Large-scale absolute dent evaluation campaign  

International Nuclear Information System (INIS)

Steam generator tube denting is primarily caused by build-up of corrosion products at the tubesheet and the tube support plates. The mechanism of dent growth and the identification of tubes which should be removed from service have been studied. The practical outcome has been to prevent in-service tube leaks and to avoid unnecessary plugging of large numbers of tubes. A finite element study of tubesheet deformation (of pulled leaking tubes from reactors) was undertaken. Profilometry results for characterizing dents are given. Although several modifications have been made the high resolution profilometry system performance and the results obtained have proved satisfactory. (U.K.).

225

Large scale breeder reactor pump dynamic analyses  

Energy Technology Data Exchange (ETDEWEB)

The lateral natural frequency and vibration response analyses of the Large Scale Breeder Reactor (LSBR) primary pump were performed as part of the total dynamic analysis effort to obtain the fabrication release. The special features of pump modeling are outlined in this paper. The analysis clearly demonstrates the method of increasing the system natural frequency by reducing the generalized mass without significantly changing the generalized stiffness of the structure. Also, a method of computing the maximum relative and absolute steady state responses and associated phase angles at given locations is provided. This type of information is very helpful in generating response versus frequency and phase angle versus frequency plots.

1982-01-01

226

Flatte-like distributions and the a{sub 0}(980)/f{sub 0}(980) mesons  

Energy Technology Data Exchange (ETDEWEB)

We explore the features of Flatte-like parametrizations. In particular, we demonstrate that the large variation in the absolute values of the coupling constants to the {pi}{eta} (or {pi}{pi}) and K anti K channels for the a{sub 0}(980) and f{sub 0}(980) mesons that one can find in the literature can be explained by a specific scaling behaviour of the Flatte amplitude for energies near the K anti K threshold. We argue that the ratio of the coupling constants can be much better determined from a fit to experimental data. (orig.)

2005-03-01

227

Experimental study on fuzzy logic vibration control of a bridge using fail-safe magnetorheological fluid dampers  

Science.gov (United States)

This study presents a semi-active vibration control of a scaled two-span bridge structure. Magneto-rheological fluid dampers are utilized as the semi-active energy absorbing devices, and a bridge vibration control system is developed. Closed-loop control system based on fuzzy logic is used to suppress the bridge deck motion under random excitation. It is demonstrated that this fuzzy logic control system can significantly reduce the relative deck displacement using about 60% less power compared to passive on state, while the absolute deck acceleration remains practically unchanged.

2001-07-01

228

Determination of fast neutron flux distribution in irradiation sites of the Malaysian Nuclear Agency research reactor  

British Library Electronic Table of Contents (United Kingdom)

Determination of thermal to fast neutron flux ratio (ffast) and fast neutron flux (phi-fast) is required for fast neutron reactions, fast neutron activation analysis, and for correcting interference reactions. The ffast and subsequently phi-fast were determined using the absolute method. The ffast ranged from 48 to 155, and the phi-fast was found in the range 1.03x1010-4.89x1010 n cm-2 s-1. These values indicate an acceptable conformity and applicable for installation of the fast neutron facility at the MNA research reactor.

2011-01-01

229

Confrontation between stellar pulsation and evolution; Proceedings of the Conference (ASP Series, Vol. 11), Bologna, Italy, May 28-31, 1990  

International Nuclear Information System (INIS)

Attention is given to the folowing topics: population I and II variable stars; LP variables, the sun, and mass determination; and predegenerate and degenerate variables. Particular papers are presented on alternative evolutionary approaches to the absolute magnitude of the RR Lyrae variables; the evolution of the Cepheid stars; nonradial pulsations in rapidly rotating Delta Scuti stars; dynamical models of dust shells around Mira variables; and pulsations of central stars of planetary nebulae.

1990-05-28

230

COBE confounds the cosmologists  

Energy Technology Data Exchange (ETDEWEB)

The validity of the Big Bang theory is evaluated. The basis of the Big Band theory and the supercluster observations of Tully, which conflict with the Big Band theory, are discussed. Various explanations for the existence of supercluster observations are proposed. The cosmic background explorer (COBE) is being utilized to detect energetic processes. The COBE contains a far IR absolute spectrometer, a differential microwave radiometer, and a diffuse IR background experiment. The hypothesis of the evolution of the universe of Hannes Alfven, which emphasizes the importance of electricity and magnetism, is presented and research illustrating the importance of electric currents and magnetic fields in space is examined.

1990-03-01

231

Absolute calibration of the antiproton detection efficiency for BESS below 1 GeV  

Energy Technology Data Exchange (ETDEWEB)

An accelerator beam experiment was performed using a low-energy antiproton beam to measure antiproton detection efficiency of the BESS detector. Measured and calculated efficiencies derived from the BESS Monte Carlo simulation based on GRANT/GHEISHA showed good agreement. With detailed verification of the BESS simulation, the relative systematic error of detection efficiency derived from the BESS simulation has been determined to be {+-}5%, compared with the previous estimation of {+-}15% which was the dominant uncertainty for measurements of cosmic-ray antiproton flux. (author)

2001-12-01

232

A navigation filter for fusing DTM/correspondence updates  

CERN Document Server

An algorithm for pose and motion estimation using corresponding features in images and a digital terrain map is proposed. Using a Digital Terrain (or Digital Elevation) Map (DTM/DEM) as a global reference enables recovering the absolute position and orientation of the camera. In order to do this, the DTM is used to formulate a constraint between corresponding features in two consecutive frames. The utilization of data is shown to improve the robustness and accuracy of the inertial navigation algorithm. Extended Kalman filter was used to combine results of inertial navigation algorithm and proposed vision-based navigation algorithm. The feasibility of this algorithms is established through numerical simulations.

2011-01-01

233

A measurement of the cross section for electron impact ionization of Ar"2"+, Kr"2"+ and Xe"2"+  

International Nuclear Information System (INIS)

The crossed electron-ion beams technique was used to measure absolute cross sections for single ionization of Ar"2"+, Kr"2"+ and Xe"2"+ ions at electron energies ranging from threshold to 2000 eV. In contrast to some previous measurements, the metastable contents of the ion beams were small even in the case of Xe"2"+. All measured cross section curves show significant contributions from excitation-autoionization and possibly direct ionization of inner-shell electrons. There is evidence for resonance-excitation-double-autoionization in the case of Xe"2"+. (author).

234

System 80+{trademark} Standard Design: CESSAR design certification. Volume 9: Amendment I  

Energy Technology Data Exchange (ETDEWEB)

This report, entitled Combustion Engineering Standard Safety Analysis Report -- Design Certification (CESSAR-DC), has been prepared in support of the industry effort to standardize nuclear plant designs. These volumes describe the Combustion Engineering, Inc. System 80{sup +}{trademark} Standard Design. This volume 9 discusses Electric Power and Auxiliary Systems.

1990-12-21

235

System 80+{trademark} Standard Design: CESSAR design certification. Volume 8: Amendment I  

Energy Technology Data Exchange (ETDEWEB)

This report, entitled Combustion Engineering Standard Safety Analysis Report -- Design Certification (CESSAR-DC), has been prepared in support of the industry effort to standardize nuclear plant designs. These volumes describe the Combustion Engineering, Inc. System 80{sup +}{trademark} Standard Design. This volume 8 provides a description of instrumentation and controls.

1990-12-21

236

System 80+trademark Standard Design: CESSAR design certification  

International Nuclear Information System (INIS)

This report, entitled Combustion Engineering Standard Safety Analysis Report -- Design Certification (CESSAR-DC), has been prepared in support of the industry effort to standardize nuclear plant designs. These volumes describe the Combustion Engineering, Inc. System 80"+trademark Standard Design. This volume 11 discusses Radiation Protection, Conduct of Operations, and the Initial Test Program.

237

Survey of state water quality standards for wetlands  

Energy Technology Data Exchange (ETDEWEB)

This document summarizes the degree to which State water quality standards include wetlands in their definitions of State waters. The detailed review of other elements of standards, such as uses, criteria and antidegradation, is beyond the scope of this review. The purpose of this review is to provide a baseline of information for the development of EPA guidance and policies related to water quality standards for wetlands.

1989-08-17

239

Reference standard for carbonaceous impurity measurements in carbon nanotubes  

Science.gov (United States)

Near-infrared spectroscopy is a convenient tool for measuring nanotube / carbonaceous impurities

2004-01-01

240

Plutonium Finishing Plant (PFP) Standards/Requirements Identification Document (S/RID)  

International Nuclear Information System (INIS)

This Standards/Requirements Identification Document (S/RID) sets forth the Environmental Safety and Health (ESH) standards/requirements for the Plutonium Finishing Plant (PFP). This S/RID is applicable to the appropriate life cycle phases of design, construction, operation, and preparation for decommissioning. These standards/requirements are adequate to ensure the protection of the health and safety of workers, the public, and the environment.

1998-06-01

243

Industrial experience with an intelligent AC/DC standard  

Energy Technology Data Exchange (ETDEWEB)

AC/DC voltage standards based entirely on solid-state references used as secondary, working, or transfer standards is widespread, although metrological performance is typically defined only via comparison with a higher level standard. The present report shows the improvements of the output metrological characteristics of an ac/dc calibrator by establishing three internal hierarchical levels of dc voltage references and by constant calibration of ac measuring circuits.

1989-04-01

244

Estimation of half-life values of actinide radionuclides  

International Nuclear Information System (INIS)

... actinides americium 241 americium 242 americium 243 calibration standards

1986-04-15

247

Development of a Standard Data Base and Computer ...  

Science.gov (United States)

... (Author). Descriptors : (*TERMINAL FLIGHT FACILITIES ... PROGRAMMING, HANDLING), QUEUEING THEORY, STOCHASTIC PROCESSES ...

1973-01-01

248

Development document for proposed effluent limitations guidelines, new source performance standards, and pretreatment standards for the steam electric point source category. Interim report  

Science.gov (United States)

This document provides a technical basis for the revision of chemical effluent limitations guidelines for the Steam Electric Power Industry reflecting the Best Available Technology Economically Achievable (BATEA) for existing sources, New Source Performance Standards (NSPS) and Pretreatment Standards. The analysis of pollutants and the technologies applicable to their control has been based on specific waste streams of concern.

1980-09-01

249

Development Document for Proposed Effluent Limitations Guidelines, New Source Performance Standards, and Pretreatment Standards for the Ink Formulating Point Source Category.  

Science.gov (United States)

This document presents the findings of a study of the Ink Manufacturing Industry for the purpose of developing effluent limitations and standards, and pretreatment standards for existing and new sources to implement Sections 301, 304, 306, 307 and 501 of ...

1979-01-01

251

OSHA Hazardous-Chemical Occupational Exposure Standard for laboratories: A new management regulation to ensure employee health. Final report  

Energy Technology Data Exchange (ETDEWEB)

The OSHA's chemical occupational exposure standard for laboratories is an outgrowth of the previously issued Hazard Communication Standard. The standard relieves laboratories from complying with general industry standards but does not require compliance with specific guidelines. The heart of the standard is the creation of a Chemical Hygiene Plan (CHP) in every laboratory. The CHP addresses major issues such as safety equipment and procedures, work practices and training, the designation of a chemical hygiene officer, and the provision of medical consultation and examination for affected employees. This new standard, in effect as of 31 January, 1991, presents yet another regulatory challenge to laboratory managers but also will ensure a safer work environment for laboratory workers.

1991-04-01

252

ISO - ISO Standards - TC 156 - Corrosion of metals and alloys  

Wastenet

...ISO - ISO Standards - TC 156 - Corrosion of metals and alloys go to main navigation go to content area go to search International Standards for Business,...ISO Members FAQs Fr ISO Store Products ISO Standards By TC TC 156 Corrosion of metals and alloys ISO Store ISO Standards By ICS By ...aerospace standards Publications and e-products ISO Concept Database (ISO/CDB) Copyright TC 156 - Corrosion of metals and alloys Items to be displayed: Published ...responsibility of TC 156 Secretariat Standard and/or project Stage ICS 3ISO/WD 7441 Corrosion of metals and alloys Determination of bimetallic corrosion in outdoor ...

253

Formulation and practice of standards for radiation protection of #gamma#-ray industrial computed tomography  

International Nuclear Information System (INIS)

There are many differences between industrial CT and industrial radiography, such as imaging principle, inspection time, radiation dose and the requirements for operators etc. The national standards for radiation protection of industrial detection are not applicable to the requirements of protection and safety for #gamma#-ray industrial CT to some extent now. In order to standardize the production and use for #gamma#-ray industrial CT, protect the safety of operators and the public, and to promote the popularization and application of #gamma#-ray industrial CT, it is significant to establish the national standards for radiation protection of #gamma#-ray industrial CT as soon as possible. The purpose of this paper is to introduce the contents of this standard, and specify some important terms. Then there is a brief discussion on the existing problems during establishing such ...

2009-03-01

254

Extensions to the VME hardware and software standards for the physics community  

Energy Technology Data Exchange (ETDEWEB)

With the ubiquitous availability of commercial VME modules and interface chips many experiments in all branches of Experimental Physics are turning to VME as the module packaging and backplane protocol of choice for application specific modules. The current VME backplane, electrical, and mechanical standards are clearly lacking when it comes to implementing the analogue and digital front end modules that Physics experiments rely on to provide the needed high speed and intelligent solutions to their data collection requirements. To address these needs the European ESONE and American VME-P committees are collaborating with the ANSII and ISO standards committees, and the VME VITA/VSO manufacturers associations, to define standard extensions to the VME protocols for such HEP needs as ``sparse data scans``, standard uses and implementations of previously user defined pins and connectors, ...

1995-10-01

255

Global residential appliance standards  

Energy Technology Data Exchange (ETDEWEB)

In most countries, residential electricity consumption typically ranges from 20% to 40% of total electricity consumption. This energy is used for heating, cooling, refrigeration and other end-uses. Significant energy savings are possible if new appliance purchases are for models with higher efficiency than that of existing models. There are several ways to ensure or encourage such an outcome, for example, appliance rebates, innovative procurement, and minimum efficiency standards. This paper focuses on the latter approach. At the present time, the US is the only country with comprehensive appliance energy efficiency standards. However, many other countries, such as Australia, Canada, the European Community (EC), Japan and Korea, are considering enacting standards. The greatest potential impact of minimum efficiency standards for appliances is in the developing countries (e.g., China and India), where ...

1993-03-01

256

Workshop on tritium safety and environmental effects, October 15--17, 1990, Aiken, South Carolina: Session summaries  

Energy Technology Data Exchange (ETDEWEB)

A meeting was held on October 15, 16, 17, 1990 to discuss the state of tritium safety and environmental effects. The meeting was organized with the help of the International Energy Agency planning committee consisting of K. Steinmetz, Y. Seki, G. Nardella, and G. Vivian. Representative of tritium production facilities and heavy water reactor power production were also involved. The meeting was organized to address seven topics in tritium safety that were thought to require further work. The topics were: (1) materials science, (2) environmental models, (3) environmental model validation, (4) tritiated organic compounds, (5) human dosimetry, (6) tritium sampling and measurement, and (7) long-term environmental databases.

1991-04-18

257

Report of the IPSM working party on low- and medium-energy x-ray dosimetry  

Energy Technology Data Exchange (ETDEWEB)

New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).

1991-08-01

258

Report of the IPSM working party on low- and medium-energy x-ray dosimetry  

International Nuclear Information System (INIS)

New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).

1991-01-01

259

Radioactive decay data tables  

Energy Technology Data Exchange (ETDEWEB)

The estimation of radiation dose to man from either external or internal exposure to radionuclides requires a knowledge of the energies and intensities of the atomic and nuclear radiations emitted during the radioactive decay process. The availability of evaluated decay data for the large number of radionuclides of interest is thus of fundamental importance for radiation dosimetry. This handbook contains a compilation of decay data for approximately 500 radionuclides. These data constitute an evaluated data file constructed for use in the radiological assessment activities of the Technology Assessments Section of the Health and Safety Research Division at Oak Ridge National Laboratory. The radionuclides selected for this handbook include those occurring naturally in the environment, those of potential importance in routine or accidental releases from the nuclear fuel cycle, those of current interest in nuclear medicine and fusion reactor technology, and some of ...

1981-01-01

260

Radiation therapy and Ewing's sarcoma in childhood  

International Nuclear Information System (INIS)

Despite high local control rate in Ewing's sarcoma the exact indication of radiation therapy is still controversial as well as the choice of the target volume and the optimal dose of radiation. The importance of the quality of radiotherapy has been stressed in recently published data and has shown a significant impact on long term local control with adequate radiation therapy. The dramatic improvement of precision allowed by the conformal therapy and three dimensional dosimetry allow to expect a decrease of late effects expected for second malignancies. However, late sequelae and radio-induced osteosarcoma still remain the major side effects after radiotherapy. The authors discuss the results of the main trials on Ewing's sarcoma on the choice of dose and target volume. Surgery is still the preferred choice for small tumors if the foreseen outcome is identical. (authors). 28 refs.

261

Radiation protection  

International Nuclear Information System (INIS)

The book presents a very good account of all aspects of protection from ionizing radiation. The quantities and units are given and defined used in nuclear physics and dosimetry. The effects of ionizing radiation on cells and on man are described. The principles are presented of radiation protection including limits and valid regulations and decrees. Also discussed is internal irradiation and its modelling. A great part of the book is devoted to aspects of monitoring persons, the living and working environment and to the determination of internal contamination. The system of radiation protection in Czechoslovakia is described and some practical questions are discussed of protection during radiodiagnosis and radiotherapy, in the nuclear fuel cycle, in the operation of nuclear power installations and in crack detection. In conclusion a survey is given of the population exposure from various natural and artificial sources. (M.D.). 57 figs., 34 tabs., 138 refs.

1988-01-01

262

Photon beam modelling with Pinnacle3 Treatment Planning System for a Rokus M Co-60 Machine  

International Nuclear Information System (INIS)

The basic relationships of the convolution/superposition dose calculation technique are reviewed, and a modelling technique that can be used for obtaining a satisfactory beam model for a commercially available convolution/superposition-based treatment planning system is described. A fluence energy spectrum for a Co-60 treatment machine obtained from a Monte Carlo simulation was used for modelling the fluence spectrum for a Rokus M machine. In order to achieve this model we measured the depth dose distribution and the dose profiles with a Wellhofer dosimetry system. The primary fluence was iteratively modelled by comparing the computed depth dose curves and beam profiles with the depth dose curves and crossbeam profiles measured in a water phantom. The objective of beam modelling is to build a model of the primary fluence that the patient is exposed to, which can then be used for the calculation of the dose deposited in the patient. (authors)

263

Organ doses received by atomic bomb survivors during radiological examinations at the Radiation Effects Research Foundation  

Energy Technology Data Exchange (ETDEWEB)

When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).

1991-08-01

264

Organ doses received by atomic bomb survivors during radiological examinations at the Radiation Effects Research Foundation  

International Nuclear Information System (INIS)

When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).

1991-01-01

265

Monte Carlo code comparisons for the calculation of absorbed dose per unit fluence in slab phantoms for electron energies from 50 keV to 10 MeV  

International Nuclear Information System (INIS)

The MCNPE-BO and MCNP4 Monte Carlo electron-photon codes were used to calculate the dose equivalent per unit fluence at various depths in tissue-equivalent slab phantoms for broad parallel beams of monoenergetic electrons with energies from 50 keV to 10 MeV. The study was carried out in the framework of the activities of a ICRP/ICRU Joint Task Group with the support of EURADOS WG4 (Numerical Dosimetry). Some preliminary results and comparisons as well as a general discussion on the performances of the codes are presented, demonstrating quite a satisfactory agreement among the results obtained using the two codes and those of other authors. (author).

266

Measurement of radon daughter product burden by TLD dosemeters  

International Nuclear Information System (INIS)

A miniature device is described for measuring integral potential alpha energy concentration of radon daughter products (Csub(Rn)) for personnel and stationary dosimetry. The measuring apparatus consists of an air sampler, filters and TLD detectors. CaSO_4:Dy-teflon pellets were used as the detectors which registrate #gamma# radiation as well. The TLD-effect dependence on the potential alpha energy, as well as the fading of the detectors at 20-60 deg C after 170 hrs operation are presentd. The fading up to 40 deg C has been found to be negligible. The dosimeter may be used to measure Csub(Rh) starting with the 10"5 MeVxh/1 threshold, the accuracy being not worse than +-30%.

267

IAEA RESEARCH CONTRACTS FIRST ANNUAL REPORT. Technical reports Series No. 4  

Science.gov (United States)

Summaries are included of research contracts which expired prior to Dec. 31, 1960. The contracts were concerned with investigations of: electrophysiological responses of biological systems in nerve cells to irradiation with small doses of ionizing radiations; the mode of the protective action of certain sulfhydryl compounds against radiation effects on the synthesis of deoxyribonucleic acid, using tritium-labeled thymidine; development of a bubble chamber method of monitoring and dosimetry for Low fast neutron fluxes; effects of incorporated radioisotopes on the stability of genetic materials; interrelation of root and leaf absorption of radioisotopes in herbaceous plants; uptake of radioactive wastes by lowland rice from soils contaminated by irrigation water, and decontamination of the rice; and comparison between mutation rates induced by acute and chronic gamma irradiations. (B.O.G.)

1961-01-01

268

Health and Safety Research Division progress report for the period April 1, 1987--September 30, 1988  

Energy Technology Data Exchange (ETDEWEB)

The mission of the Health and Safety Research Division (HASRD) is to provide a sound scientific basis for the measurement and assessment of human health impacts of radiological and chemical substances. Our approach to fulfilling this mission is to conduct a broad program of experimental, theoretical, and field research based on a strong foundation of fundamental physical studies that blend into well-established programs in life sciences. Topics include biomedical screening techniques, biological and chemical sensors, risk assessment, health hazards, dosimetry, nuclear medicine, environmental pollution monitoring, electron-molecule interactions, interphase physics, surface physics, data base management, environmental mutagens, carcinogens, and tetratogens.

1989-03-01

269

Electronics Personal Dosemeter (EPD-N) Test and Evaluation Report  

Energy Technology Data Exchange (ETDEWEB)

Three electronic personal dosimeters (EPD-N) manufactured by Siemens, serial numbers 0635, 0658, and 0683, were tested at the Radiation Calibration Laboratory for an evaluation of their response to neutron, gamma and x-ray radiation. Designed to provide real-time neutron and photon dosimetry, the EPD-N is capable of estimating and displaying neutron and gamma dose components separately for a range of energies from 50 keV to 7 MeV for photon and 0.025 eV to > 10 MeV for neutron. All tests were conducted using the factory calibrations. A technical representative of the manufacturer indicated that site-specific calibrations are required as factory settings are calibrated for the lowest neutron energy limit of 0.025 eV. This raises concerns about the reliability of these devices in measuring neutrons when calibrations are made for a specific site radiological characterization then used at another site.

2003-04-08

270

Efficiency of a lead-containing tie for radiation protection of the thyroid gland  

Energy Technology Data Exchange (ETDEWEB)

During fluoroscopy the examiner is usually protected by a radiation-reducing body shield, leaving the thyroid unprotected. The fact that the thyroid is located in a region of the neck usually covered by the shirt collar led to the idea of designing a tie with lead core, providing easy and ''decorative'' reduction of the radiation dose. Sonographic examinations were carried out in 20 volunteers (10 men, 10 women) to determine the size of the gland and its coverage by such a tie. The reduction of the surface and organ dose was assessed using film dosimetry with scattered radiation, the body of the examiner being simulated by an Alderson phantom. On average 88% of the thyroid gland surface area was covered. Surface dose was reduced to 1%, and organ dose to 10% of the value without the protection tie. (Author).

1992-11-01

271

Efficiency of a lead-containing tie for radiation protection of the thyroid gland  

International Nuclear Information System (INIS)

During fluoroscopy the examiner is usually protected by a radiation-reducing body shield, leaving the thyroid unprotected. The fact that the thyroid is located in a region of the neck usually covered by the shirt collar led to the idea of designing a tie with lead core, providing easy and ''decorative'' reduction of the radiation dose. Sonographic examinations were carried out in 20 volunteers (10 men, 10 women) to determine the size of the gland and its coverage by such a tie. The reduction of the surface and organ dose was assessed using film dosimetry with scattered radiation, the body of the examiner being simulated by an Alderson phantom. On average 88% of the thyroid gland surface area was covered. Surface dose was reduced to 1%, and organ dose to 10% of the value without the protection tie. (Author).

272

Effective dose equivalent concept in radiopharmaceutical dosimetry  

Energy Technology Data Exchange (ETDEWEB)

The Effective Dose Equivalent Concept defined by the International Commission on Radiological Protection in 1977 considers the risk from irradiation including both hereditary and somatic effects. This paper will deal with the definition of a concept for somatic effects only, the somatically significant dose equivalent. This is defined as the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by various individuals. The somatically effective dose equivalent for a particular radiopharmaceutical is the weighted sum of the average dose equivalent to various organs. The dose equivalent to various organs can be derived from an extended MIRD formalism also considering the rest of body excluding the source volumes and the re iden e times in total body and the target organs. Examples are given for the calculation of somatically effective dose equivalent for ...

1981-06-01

273

Effective dose equivalent concept in radiopharmaceutical dosimetry  

International Nuclear Information System (INIS)

The Effective Dose Equivalent Concept defined by the International Commission on Radiological Protection in 1977 considers the risk from irradiation including both hereditary and somatic effects. This paper will deal with the definition of a concept for somatic effects only, the somatically significant dose equivalent. This is defined as the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by various individuals. The somatically effective dose equivalent for a particular radiopharmaceutical is the weighted sum of the average dose equivalent to various organs. The dose equivalent to various organs can be derived from an extended MIRD formalism also considering the rest of body excluding the source volumes and the re iden e times in total body and the target organs. Examples are given for the calculation of somatically effective dose equivalent for ...

274

Dosimetry of iodine-123 iomazenil in humans  

International Nuclear Information System (INIS)

The distribution of the central benzodiazepine receptor specific ligand iodine-123 iomazenil was investigated in seven human adults from whole-body scans, blood samples and urine collected up to 24 h after injection. Using 12 source organs, the MIRD method was applied to calculate the absorbed radiation dose of the radioligand in various organs. The urinary bladder wall (0.15 mGy/MBq), lower large intestinal wall (0.071 mGy/MBq) testes (0.044 mGy/MBq) and upper large intestined wall (0.038 mGy/MBq) received the highest absorbed doses. The average effective dose equivalent of "1"2"3I-IBZM for adults was estimated to be 0.033 mSv/MBq. (orig.).

275

Comparative dosimetry for screen film systems and intensifier fluorography in urinary incontinence of women  

International Nuclear Information System (INIS)

In 16 female patients wick colpourethrocystography was performed directly successively with large-size films as well as medium-size films (intensifier fluorography). The area exposure products were measured by a dosemeter closely attached to the diaphragm and separately for radiography and fluorography, resp. Surface doses as well as organ doses were calculated according to Rosenstein. The average radiatin doses of the active bone marrow were 6.03 mGy for examination with large-size films and 1.27 mGy for fluorography; the average gonadal doses were 7.45 mGy and 1.56 mGy, resp. The portion of fluoroscopy in radiation exposure amounted to 14.8% in large-size film examination, but was 74.0% in medium-size examination. Thus the comparative results revealed a significant reduction of the patient's radiation dose by application of intensifier fluorography in colpourethrocystography.

1987-01-01

276

Clinical application of dosimetry in electron beam therapy  

International Nuclear Information System (INIS)

In everyday radiotherapy we must carry out the determination of absorbed dose measurement according to JARP's protocol. We explained an outline of JARP's 1974 and 1986 protocol in electron beam therapy, and mentioned it about the matter that should examined. To use it easily in clinic, a simplified procedure based on precisely to JARP's 1986 protocol is practical, the character of this procedure settles briefly the determination of mean incident energy of electron beams and get ready to table of ionization to absorbed dose conversion factor for various ionization chamber. Also, this procedure almost not influence on the accuracy of determination. We described systematically practical procedure for requisite absorbed dose calculation in a patient in electron beam therapy. (author).

277

An integrating dosimeter for pulsed radiation  

Science.gov (United States)

A Pulsed Radiation Dosimetry System designed to measure radiation produced by particle accelerators is described. The problems associated with total-dose measurement of irregular shaped pulses of ionizing radiation have been simplified. The system responds to extremely narrow pulses of charged particles or X-rays using a pin diode as the detector. Direct readout of dose in rads (Si) is displayed on a 3-1/2 digit digital panel meter. The system will operate in either the multiple-pulse or single-pulse mode. The multiple-pulse mode would be useful in monitoring or tuning a linear accelerator. In the single-pulse mode the system will automatically display total dose of a transient event in real time and hold that measurement indefinitely or until the next measurement is made. The system features an automatic reset in either mode.

1983-12-01

278

A study on the real-time radiation dosimetry measurement system based on optically stimulated luminescence  

International Nuclear Information System (INIS)

The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous radiation occasions. (authors)

2008-05-01

279

A routine chemical dosimetric system using the modified ceric sulphate dosimeter  

International Nuclear Information System (INIS)

The radiolytic reduction of the Ce4+ in a 0.8N sulfuric acid was examined, with the objective of measuring large radiation doses. the ceric sulphate dosimeter was tested in the range from 1 to 20kGy. The 0.01 M sodium oxalate solution was chosen instead of the arsenious oxide solution (used in the conventional method), in order to obtain a less expensive dosimetric system than that normally use for routine chemical dosimetry. The absorption spectrum of the Ce"4"+ solution presents an absorption peak at 370 nm; the obtained molar extinction coefficients of Ce"4"+ and Ce"3"+ were 5670 and 2.7 M"-"1 cm"-"1 respectively. The purpose of this work was to establish a simple, reliable and inexpensive routine chemical dosimetric system for high doses.

1994-10-01

280

A computer program for rapid calculation of internal committed effective dose through inhalation and ingestion pathways under radiological emergency  

International Nuclear Information System (INIS)

Objective: To establish a computer program for rapid calculation of internal committed effective close through inhalation and ingestion pathways under radiological emergency. Methods: Visual Basic 6.0 is used to compile the generic procedures of internal committed effective dose by inhalation and ingestion in IAEA-TECDOC-1162, Generic Procedures for Assessment and Response during a Radiological Emergency. Results: The assessment methodology of internal committed effective dose by inhalation and ingestion under radiological emergency in the report IAEA-TECDOC-1162 can be coded into a computer program. Conclusions: This research provides a rapid method of assessment for internal committed effective dose by inhalation and ingestion under radiological emergency, and it may provide needed dosimetry data for treatment under emergency response. (authors)

2008-08-01

281

Status of the ANS low power and shutdown PRA standard  

Energy Technology Data Exchange (ETDEWEB)

The Low Power and Shutdown (LPSD) PRA (Probabilistic Risk Assessment) Standard (ANS-58.22) is currently being drafted by a Writing Group under the auspices of the Risk Informed Standards Committee of the American Nuclear Society (ANS). The Writing Group includes representatives from nuclear utilities, US Nuclear Regulatory Commission (NRC), national laboratories, universities, and consultants with substantial experience producing LPSD PRAs. This draft standard is scheduled to be released for public comment in the second quarter of 2004, with publication by the end of 2004. The LPSD PRA Standard is based on a mature technology that shares many requirements with full power PRAs. It will provide specific methods and criteria whereby PRAs of appropriate quality and scope can be used in the conduct of plant decision-making and other activities, including addressing NRC requirements. This paper presents the ...

2004-07-01

282

IEEE standard quality assurance program requirements for the design and manufacture of class 1E instrumentation and electric equipment for nuclear power generating station  

International Nuclear Information System (INIS)

The Institute of Electrical and Electronic Engineers (IEEE) standards for the quality assurance requirements for the design and manufacture of Class 1E instrumentation and electric equipment for a nuclear power generating station are presented. This standard establishes Quality Assurance Program requirements for electrical manufacturers. This standard, used in conjunction with ANSI N45.2-1977 and the supplemental standards to the extent referenced in this standard, is intended to meet the requirements of 10CFR50, Appendix B. These requirements are intended to assure that Class 1E instrumentation and electric equipment are responsibly engineered and manufactured from proper materials, that the manufacturing processes and practices are controlled, and that the manufacturing process produces a product of the required quality for Class 1E application.

283

IEEE [Institute of Electrical and Electronics Engineers] standards and nuclear software quality engineering  

International Nuclear Information System (INIS)

Significant new nuclear-specific software standards have recently been adopted under the sponsorship of the American Nuclear Society and the American Society of Mechanical Engineers. The interest of the US Nuclear Regulatory Commission has also been expressed through their issuance of NUREG/CR-4640. These efforts all indicate a growing awareness of the need for thorough, referenceable expressions of the way to build in and evaluate quality in nuclear software. A broader professional perspective can be seen in the growing number of software engineering standards sponsored by the Institute of Electrical and Electronics Engineers (IEEE) Computer Society. This family of standards represents a systematic effort to capture professional consensus on quality practices throughout the software development life cycle. The only omission-the implementation phase-is treated by accepted American National Standards ...

1988-06-12

284

Retrospective Monte Carlo dose calculations with limited beam weight information  

International Nuclear Information System (INIS)

An important unresolved issue in outcomes analysis for lung complications is the effect of poor or completely lacking heterogeneity corrections in previously archived treatment plans. To estimate this effect, we developed a novel method based on Monte Carlo (MC) dose calculations which can be applied retrospectively to RTOG/AAPM-style archived treatment plans (ATP). We applied this method to 218 archived nonsmall cell lung cancer lung treatment plans that were originally calculated either without heterogeneity corrections or with primitive corrections. To retrospectively specify beam weights and wedges, beams were broken into Monte Carlo-generated beamlets, simulated using the VMC++ code, and mathematical optimization was used to match the archived water-based dose distributions. The derived beam weights (and any wedge effects) were then applied to Monte Carlo beamlets regenerated based on the patient computed tomography densities. Validation of the process was performed against five ...

2007-01-01

285

Multi-Phase Fracture-Matrix Interactions Under Stress Changes  

Energy Technology Data Exchange (ETDEWEB)

The main objectives of this project are to quantify the changes in fracture porosity and multi-phase transport properties as a function of confining stress. These changes will be integrated into conceptual and numerical models that will improve our ability to predict and optimize fluid transport in fractured system. This report details our progress on: (a) developing the direct experimental measurements of fracture aperture and topology and fluid occupancy using high-resolution x-ray micro-tomography, (b) counter-current fluid transport between the matrix and the fracture, (c) studying the effect of confining stress on the distribution of fracture aperture and two-phase flow, and (d) characterization of shear fractures and their impact on multi-phase flow. The three-dimensional surface that describes the large-scale structure of the fracture in the porous medium can be determined using x-ray micro-tomography with significant accuracy. Several fractures have been scanned and the ...

2005-12-07

286

The first international standard for antibodies to double stranded DNA.  

UK PubMed Central (United Kingdom)

This paper announces the availability of the first international standard for anti-double-stranded DNA (anti-dsDNA). The material, coded Wo/80, was obtained after recalcification of plasma taken from...Full Text Available

1988-09-01

287

Site Investigation Report. Volume 2. 120th Fighter Interceptor ...  

Science.gov (United States)

... MCL Maximum contaminant level NAAQS National ambient air quality standards NCP National ... 3. Estimated Cost Impacts: I3a. ... Standard Additions. ...

1992-02-01

288

Producing the future: a powerful security standard and new Internet protocols are among the innovations being hatched at MIT(Q & A)(Interview)  

CERN Document Server

Producing the future: a powerful security standard and new Internet protocols are among the innovations being hatched at MIT(Q & A)(Interview)

2004-01-01

290

Juvenile salmon with high standard metabolic rates have higher energy costs but can process meals faster  

UK PubMed Central (United Kingdom)

Basal or standard metabolic rate (SMR) has been found to exhibit substantial intraspecific variation in a range of taxa, but the consequences of this variation are little understood. Here we explore...Full Text Available

2009-06-07

291

Efficacy of standard glucose-based and reduced-osmolarity maltodextrin-based oral rehydration solutions: effect of sugar malabsorption.  

UK PubMed Central (United Kingdom)

Previously we reported that standard oral rehydration salts (ORS) solution is not as effective as a reduced-osmolarity glucose-based ORS for the treatment of children with acute noncholera diarrhoea:...Full Text Available

1996-01-01

292

Economic Impact Analysis of Proposed Effluent Limitations Guidelines and Standards for the Centralized Waste Treatment Industry.  

Science.gov (United States)

This report estimates the economic and financial effects of compliance with the proposed effluent limitations guidelines and standards for the Centralized Waste Treatment (CWT) industry. The Environmental Protection Agency (EPA) has measured these impacts...

1995-01-01

293

EFFECTS OF ALTERNATIVE NEW SOURCE PERFORMANCE STANDARDS ON FLUE GAS DESULFURIZATION SYSTEM SUPPLY AND DEMAND  

Science.gov (United States)

The report discusses the capabilities of equipment vendors to supply and install the quantity of flue gas desulfurization systems required to meet alternative standards for coal-fired steam generators. It analyzes limiting factors affecting supply capabilities (such as the availa...

294

Development Document for Proposed Effluent Limitations Guidelines and Standards for the Concentrated Aquatic Animal Production Industry Point Source Category.  

Science.gov (United States)

This section presents background information supporting the development of effluent limitations guidelines and standards for the concentrated aquatic animal production (CAAP) point source category. Section 1.1 presents the legal authority to regulate the ...

2002-01-01

295

Development Document for Proposed Effluent Limitations Guidelines and New Source Performance Standards for the Ore Mining and Dressing: Point Source Category.  

Science.gov (United States)

This document presents the findings of an extensive study of the ore mining and dressing industry, for the purpose of developing effluent limitations guidelines for existing point sources and standards for performance new sources, to implement Sections 30...

1982-01-01

296

Current issues of nuclear equipment standardization in Romania  

International Nuclear Information System (INIS)

Standardization enhances: international cooperation; development of new nuclear techniques and technologies; characterization and checking procedures of equipment; sharing a common terminology. A historical sketch is given focussing: inception of standardization in electro-techniques at international scale; organization of the International Electrotechnical Commission, IEC; - current aspects of nuclear equipment standardization; activity of seven working groups devoted to nuclear reactor equipment; activity of seven groups working on radioprotection equipment; activity of four groups working on nuclear equipment. ISO organization and present issues concerning the nuclear technology development in Romania. It is presented the activity in the frame of CENELEC, CLC/TC45, for endorsing the IEC/TC45B standards. In 2007 a CENELEC/ BTT 127-1 working commission was formed to enhance assimilation of IEC /TC45 A ...

2009-10-12

297

Cost-Effectiveness Analysis of Proposed Effluent Limitations Guidelines and Standards for the Metal Products and Machinery Industry (Phase 1).  

Science.gov (United States)

This cost-effectiveness analysis supports the proposed effluent limitations guidelines and standards for the Metal Products and Machinery Industry (MP and M) Phase I Industry. The report assesses the cost-effectiveness of five regulatory options for indir...

1995-01-01

298

Cost-Effectiveness Analysis of Proposed Effluent Limitations Guidelines and Standards for the Centralized Waste Treatment Industry.  

Science.gov (United States)

This analysis, submitted in support of proposed effluent limitations guidelines and standards for the centralized waste treatment (CWT) industry, investigates the cost-effectiveness of 24 regulatory options, representing all possible combinations of nine ...

1995-01-01

299

Comparison of a minimally invasive procedure versus standard microscopic discotomy: a prospective randomised controlled clinical trial  

UK PubMed Central (United Kingdom)

A Prospective randomised controlled study was done to determine statistical difference between the standard microsurgical discotomy (MC) and a minimally invasive microscopic procedure for disc prolapse...Full Text Available

2009-07-01

300

Colorectal Cancer Association of Canada consensus meeting: raising the standards of care for early-stage rectal cancer  

UK PubMed Central (United Kingdom)

The purpose of the meeting reported here was to develop a set of national evidence-based standards for assessing and managing patients with potentially resectable rectal cancer. This report represents...Full Text Available

2009-12-01

301

45 CFR 170.205 - Content exchange standards and implementation specifications for exchanging electronic health...  

Science.gov (United States)

...standards and implementation specifications for exchanging electronic health information. 170.205 Section 170.205 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES HEALTH INFORMATION TECHNOLOGY HEALTH INFORMATION TECHNOLOGY...

2010-10-01

302

45 CFR 162.404 - Compliance dates of the implementation of the standard unique health identifier for health care...  

Science.gov (United States)

...dates of the implementation of the standard unique health identifier for health care providers. 162.404 Section 162.404 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES ADMINISTRATIVE DATA...

2010-10-01

303

ent-Rosane and abietane diterpenoids as cancer chemopreventive agents  

British Library Electronic Table of Contents (United Kingdom)

Two ent-rosane- (cuzcol, 1 and 6-dehydroxycuzcol, 2) and a abietatriene- (salvadoriol, 3) type diterpenoids have been isolated from Maytenus cuzcoina and Crossopetalum uragoga, respectively, along with five known diterpene compounds (4-8). Their stereostructures have been elucidated on the basis of spectroscopic analysis, including 1D and 2D NMR techniques, and computational data. The absolute configuration of cuzcol was determined by application of Riguera ester procedure. This is the first instance of isolation of ent-rosane diterpenoids from species of the Celastraceae. The isolated diterpenes were found to be potent anti-tumour-promoter agents, and carnosol (7) also showed a remarkable chemopreventive effect in an in vivo two-stage carcinogenesis model.

2011-01-01

304

[Dysspermia due to inflammation. The evaluation of sperm cultures].  

Science.gov (United States)

The study evaluates 160 cases of positive spermioculture taken from 522 sterile individuals examined by the authors at the Couple Sterility Outpatient unit in Department A of the Institute of Gynecology and Obstetrics at Turin University during the period between January 1984 and December 1993. The germs responsible for infection were assayed in order to evaluate the strains which showed the highest incidence every year. Whereas there was no significant change in the absolute number of cases of sterility over the period, the number of cases caused by infection increased significantly during the second five-year period. It was found that the germs predominantly implicated in the genesis of male sterility formed part of the so-called mixed flora group, responsible in women for syndromes of often asymptomatic bacterial vaginosis which are not identified and consequently not treated. PMID:8559444

305

Variable structure system based logic fuzzy control of bridge vibration using fail-safe magnetorheological fluid dampers  

Science.gov (United States)

This paper presents a semi-active vibration control of a scaled two-span bridge structure. Magneto-rheological fluid dampers are utilized as the semi-active energy absorbing deices and a bridge vibration control system is developed. Closed-loop control system based on fuzzy logic is used to suppress the bridge deck motion under random excitations. The sufficient condition for the closed-loop stability of the fuzzy control system is derived from the variable structure system theory. It is demonstrated that this stable fuzzy control system can significantly reduce the relative deck displacement using about 55 percent less power compared to passive-on state, while the absolute deck acceleration is relatively unaffected.

2002-06-01

306

Reproductive toxicologic evaluations of Bulbine natalensis Baker stem extract in albino rats  

British Library Electronic Table of Contents (United Kingdom)

The effects of oral administration of aqueous extract of Bulbine natalensis Baker stem at daily doses of 25, 50, and 100mg/kg body weight on the reproductive function of Wistar rats were evaluated. The indices of mating and fertility success as well as quantal frequency increased after 7 days of treatment in all the dose groups except the 100mg/kg body weight group. The number of litters was not statistically different (P>0.05) from the control. Whereas the absolute weights of the epididymis, seminal vesicle, and prostate were not affected, that of the testes was significantly increased. The epididymal sperm count, motility, morphology, and viscosity were not different from the control after 7 days of treatment. The male rat serum testosterone, progesterone, luteinizing hormone, and follic...

2009-01-01

307

Recycling flow control device for a nuclear reactor  

International Nuclear Information System (INIS)

Object: To permit a valve operation test to be periodically made during plant operation without causing variations in plant power by detecting flow control valve defect on the basis of a valve aperture alteration instruction. Structure: Step signals which are equal in absolute value and opposite in sign are coupled to the input side of flow controllers provided on the recycling loops of two or more recycling flow control systems. With these inputs the aperture of the flow control valve on one side is increased (or reduced) while the aperture of the valve on the other side is reduced (or increased). As a result, the recycling flow rate in the loop on one side is increased (or reduced) while that on the other side is reduced (or increased). Whether the valve is normally operating or not is confirmed by checking the recycling flow rate and valve aperture. (Nakamura, S.).

308

Quantitative bone scintigraphy: follow-up of a femoral osteogenic sarcoma in an adolescent girl treated by chemotherapy and by massive allograft  

International Nuclear Information System (INIS)

Fifteen quantitative bone scintigraphies were performed in an adolescent girl during the follow-up of a femoral osteogenic sarcoma treated by chemotherapy and massive allograft. Three hours after injection of the radiopharmaceutical (7.4 MBq/kg of 99mTc-MDP) bone activity was measured in the inferior limbs at several regions of interest centered on the hips, femurs (proximal, middle, distal) and proximal tibias. The variations of relative bone activities A/S (ratio of corresponding counting rates between two homologous regions in the affected A and in the healthy S limb) and of absolute bone activities (expressed in counts/pixel-second) are interpreted as a function of times during treatment. The quantitative results are discussed with regard to main phenomena influencing bone activity in this particular clinical case: bone growth, chemotherapy and neo-osteogenesis in allograft.

309

Photo-emission-electron-microscopy for characterization of an operating organic electronic device  

Energy Technology Data Exchange (ETDEWEB)

Photoemission-electron-microscopy (PEEM) is introduced as a tool for the characterization of organic electronic devices. PEEM-measurements are used for imaging as well as for spectroscopic analyses by illumination with light of a Hg-lamp (4.9 eV), a D2 lamp (7.3 eV), and with synchrotron radiation for resonant photoelectron spectroscopy. We determine the charge carrier concentration inside the channel region of the organic device and its lateral distribution. From resonant photoelectron spectroscopy (RPES) we deduce the electronic states which are accessible with the Hg and D2 illumination. Photoelectron-spectroscopy at selected areas ({mu}-PES) gives information on the absolute values of surface potentials in lateral resolution. We are able to perform these studies with applied voltages at the source- and drain-electrode.

2006-01-20

310

Optimization techniques for parameter estimations: case studies in CO{sub 2} separation processes  

Energy Technology Data Exchange (ETDEWEB)

Application of an optimization technique to extract the non-ideal parameters of gas absorption with chemical reactions process was described. The gas absorption was modeled using mass transfer theory to represent the realistic behaviors of an absorber. The model was a highly non-linear iterative model which correlated the overall rate of absorption as the function of unknown non-ideal parameters, including the physical liquid mass transfer coefficient and the wetted interfacial area of of packings. The optimization program was developed to minimize the sum of squares of relative errors between the model predictions and the experimental data. Four sets of experimental data (case studies) with different operating conditions were used for extracting parameters. Comparisons between predicted and experimental measured overall absorption rate were in good agreement, average absolute value of relative errors not exceeding 5.4 %. 18 refs., 3 tabs., 4 figs.

1995-12-31

311

New stratigraphic markers in the late Pleistocene Palouse loess: novel fossil gastropods, absolute age constraints and non-aeolian facies  

British Library Electronic Table of Contents (United Kingdom)

Abstract Four stratigraphic sections in the southern part of the Columbia Basin preserve a sequence of aeolian and non-aeolian sediments ranging in age from 943 to >470 14C ka based on accelerator mass spectrometry radiocarbon dating of fossil molluscs, geochemistry of Cascade Mountain-sourced tephra and association with formally recognized pedostratigraphic units (the Washtucna and Old Maid Coulee soils). Study sections are interpreted as representing concurrent deposition of loess and distal Missoula Flood rhythmites in valleys tributary to main drainages backflooded during the Missoula Floods, and formation of carbonate and iron-rich soils. Sediments belong to the formally recognized L-1 and L-2 loess units established for the Palouse loess, which were deposited in the Columbia Basin su...

2010-01-01

312

Netrawalm: Network Based Resource Aware Application Layer Multicast for Multiparty Video Conference  

CERN Document Server

IP Multicast is one of the most absolute method for large bandwidth Internet applications such as video conference, IPTV, E-Learning and Telemedicine etc., But due to security and management reason IP Multicast is not enabled in Internet backbone routers. To achieve these challenges, lot of Application Layer Multicast (ALM) has been proposed. All the existing protocols such as NICE, ZIGZAG and OMNI are trying to reduce average delay by forming a Multicast tree. But still that problem has not been addressed fully. We are proposing a new protocol called NetRawALM, which will address the average delay, Reliability between nodes, Scalability of conference, Heterogeneity and resilient data distribution for real time multimedia applications by constructing the Network based Resource aware Multicast tree algorithm. This is very dynamic and decentralised. The proposed architecture is a LAN aware; it is used to reduce Internet Traffic.

2011-01-01

313

Monitoring transplanting operation of rice crop using passive microwave radiometer data  

British Library Electronic Table of Contents (United Kingdom)

This study highlights a methodology to detect the transplanting operation of wetland rice at a regional scale using SSM/I brightness temperature in frequencies like 19, 37 and 85 GHz with vertical polarization. A cloud removal algorithm was used to make weekly composites of the brightness temperature, which were used to estimate the soil wetness index (SWI). Flooding of rice fields with water for transplanting induces very high change in SWI due to contrasting dielectric constant of water (80) and soil (4). Different weather conditions and fractional wet area under the footprint of sensor affect SWI, hence absolute value of SWI was not adequate. Therefore, multi-year SWI anomaly was used to generate a threshold value of SWI change to detect when SWI change between two consecutive weeks was...

2011-01-01

314

Modification of streaming potential by precipitation of calcite in a sand-water system: laboratory measurements in the pH range from 4 to 12  

British Library Electronic Table of Contents (United Kingdom)

SUMMARY Spontaneous potentials associated with volcanic activity are often interpreted by means of the electrokinetic potential, which is usually positive in the flow direction (i.e. Zeta potential of the rock is negative). The water-rock interactions in hydrothermal zones alter the primary minerals leading to the formation of secondary minerals. This work addresses the study of calcite precipitation in a sand composed of 98 per cent quartz and 2 per cent calcite using streaming potential measurements. The precipitation of calcite as a secondary mineral phase, inferred by high calcite saturation indices and by a fall in permeability, has a significant effect on the electrokinetic behaviour, leading to a significant reduction in the Zeta potential (in absolute value) and even a change in si...

2006-01-01

315

Information flow, causality, and the classical theory of tachyons  

International Nuclear Information System (INIS)

Causal paradoxes arising in the tachyon theory have been systematically solved by using the reinterpretation principle as a consequence of which cause and effect no longer retain an absolute meaning. However, even in the tachyon theory, a cause is always seen to chronologically precede its effect, but this is obtained at the price of allowing cause and effect to be interchanged when required. A recent result has shown that this interchange-ability of cause and effect must not be unlimited if heavy paradoxes are to be avoided. This partial recovery of the classical concept of causality has been expressed by the conjecture that transcendent tachyons cannot be absorbed by a tachyon detector. In this paper the directional properties of the flow of information between two observers in relative motion and its consequences on the logical self-consistency of the theory of superluminal particles are analyzed. It is shown that the above conjecture does not provide a ...

316

Influence of intracavity doppler frequency shift in the swept-cavity ringdown spectroscopy incorporating continuous-wave laser excitation  

International Nuclear Information System (INIS)

Cavity ringdown spectroscopy (CRDS) with continuous-wave (cw) laser excitation has added high frequency resolution to the ability of CRDS being used for the absolute quantification of trace-level species present in many chemical processes. Cavity dithering technique has easily resolved the problem of resonant coupling of a cw laser light into a high-finesse cavity. The present study addresses the potential uncertainty involved in such cw-CRDS techniques incorporating the cavity mirror motion, i.e., the doppler frequency shift of a probe light inside the cavity. In the high-resolution spectroscopic work of megahertz-accuracy, even the influence of intracavity doppler effect may become significant.

2001-11-01

317

High-throughput proteomics of breast carcinoma cells: a focus on FTICR-MS  

Energy Technology Data Exchange (ETDEWEB)

Discovery of better biomarkers for diagnosis, prognosis, and therapy-response prediction is the most critical task of a scientific quest aimed at developing newly designed, tailor-made therapies for patients with cancer. Consequently, a proteome wide analysis, in addition to genomic studies, is an absolute requirement for a complete functional understanding of tumor biology. Ultra-sensitive, high-performance Fourier transform ion cyclotron resonance (FTICR) mass spectrometry (MS) currently holds an important role in fulfilling the demands of biomarker discovery. In this review, we describe the applicability of FTICR MS for breast cancer proteomics, particularly for the analysis of complex protein mixtures obtained from a limited number of cells typically available from clinical specimens.

2008-06-05

318

Geometry effects in the pulsed magnetization of high-temperature superconductor bulk parts  

International Nuclear Information System (INIS)

The dynamic response of cylindrical and ring-shaped YBaCuO bulk parts to pulsed magnetic fields is calculated by using small sets of finite elements. Some comparisons with experimental results are provided, and they give confidence in the modelling of the superconducting properties. Transient magnetizations as a function of time and space as well as shapes and absolute values of trapped magnetic flux profiles are presented. The influence of the sample geometry is investigated for different millisecond pulsed magnetization processes. Results are reported for different radial thicknesses and heights, different pulse durations, peak magnetic fields and pulse sequences with and without stepwise cooling. Comparisons concerning the achievable trapped magnetic field and flux are made, and implications for the use of high-temperature superconductor bulk parts as cryo-permanent magnets in potential applications like electric machinery are discussed.

2005-02-01

319

Feasibility analysis for attosecond X-ray pulses at FERMI@ELETTRA free electron laser  

Energy Technology Data Exchange (ETDEWEB)

We present preliminary analysis for the feasibility of the attosecond x-ray pulses at a proposed FERMI@ELETTRA free electron laser (FEL) [1]. In part 1 we restrict ourselves to minimal modifications to the proposed FEL and consider a scheme for attosecond x-ray production which can be qualified as a small add-on to a primary facility. We demonstrate that at 5-nm wavelength our scheme is capable for production of pulses with an approximate duration of 100 attoseconds at approximately 2 MW peak power and with an absolute temporal synchronization to a pump laser pulse. In part 2 we propose to use an FEL amplifier seeded by a VUV signal and to follow it by the scheme for attosecond x-ray production described in part 1.

2004-09-01

320

Fast neutron nuclear data: Pu-239 revision and Am status  

International Nuclear Information System (INIS)

Neutron cross sections for Pu-239 and Am-241, -242m, -243 have been analyzed with the aid of theoretical models. A deformed optical potential that fits total, elastic and inelastic differential cross section data and neutron strength functions for Pu-239 and Am-241 have been used. In case of Pu-239 the consistency of absolute fission data and (n, 2n) cross section is investigated. Because of the strong discrepancies in Am fission cross section data a consistent set of calculated cross section values for the chain of Am nuclei is proposed. The present state of knowledge concerning first chance fission cross section allows to analyze fission cross section data of Am-241, -242m, -243, up to 20 MeV. The results thus obtained are compared with ENDF/B-V and JENDL-3 libraries. (orig.).

321

Excitation functions and yields of the (d,p) reactions on natural molybdenum for deuteron energies less than 13 MeV  

International Nuclear Information System (INIS)

The excitation functions of the reactions "9"8Mo(d,p)"9"9Mo and "1"0"0Mo(d,p)"1"0"1Mo have been determined by irradiation of stacked foils with deuterons of energies less than 13 MeV and non-destructive determination of the absolute activity of the Mo radioisotopes by semiconductor #gamma#-ray spectrometry. From the excitation functions, the thick-target yields and the saturation production rates of "9"9Mo and "1"0"1Mo for deuteron energies of 13.0 MeV and 11.7 MeV have been calculated. Implications for the production of "9"9Mo for generators of sup(99m)Tc are discussed. (author).

322

Evidence for significant backscattering in near-threshold electron-impact excitation of Ar"7"+(3s#->#3p)  

International Nuclear Information System (INIS)

Measurements of absolute total cross sections for electron-impact excitation of Ar"7"+(3s#->#3p) using a merged-beams electron-energy-loss technique show that near threshold the inelastically scattered electrons are ejected primarily in the backward direction. This unusual angular scattering has not been previously observed for atoms or ions, but may be typical for multiply charged ions. The total cross sections, measured over an energy range to 2.2 eV above threshold, agree with seven-state R-matrix close-coupling calculations. Both close-coupling and distorted-wave calculations also confirm the backscattering observed in these measurements.

323

Evaluation of soil moisture derived from passive microwave remote sensing over agricultural sites in Canada using ground-based soil moisture monitoring networks  

British Library Electronic Table of Contents (United Kingdom)

Passive microwave soil moisture datasets can be used as an input to provide an integrated assessment of climate variability as it relates to agricultural production. The objective of this research was to examine three passive microwave derived soil moisture datasets over multiple growing seasons in contrasting Canadian agricultural environments. Absolute and relative soil moisture was evaluated from two globally available datasets from the Advanced Microwave Scanning Radiometer for EOS (AMSR-E) sensor using different retrieval algorithms, as well as relative soil wetness at a weekly scale from the Special Sensor Microwave/Imager (SSM/I) sensor. At a daily scale, the Land Parameter Retrieval Model (LPRM) provides a better estimate of surface soil moisture conditions than the National Snow a...

2010-01-01

324

Evaluation method for corrosion resistance of zirconium alloy  

International Nuclear Information System (INIS)

The present invention concerns a method of evaluating corrosion resistance of a zirconium alloy easily and in a short period of time. An anode polarization curve of the zirconium alloy is measured to obtain an anode polarization curve expressed by logarithm. The curve is converted to a potential-current density curve expressed by absolute values. The peak area in the curve of the converted potential-current density is indicated by numerical values. Further, the corrosion resistance of the zirconium alloy is evaluated based on the peak area converted into the numerical values as a reference. This method is based on the finding that the peak area has a close relation with nodular corrosion resistance, and the corrosion resistance can be judged with respect to a specific zircaloy-2. (T.M.).

1993-03-26

325

Eosinophilia after radiotherapy for non-resected cervical cancer  

International Nuclear Information System (INIS)

The behaviors of peripheral eosinophils during radiotherapy were examined in 200 cases of non-resected cervical cancer. Before irradiation, the mean absolute eosinophil count had been 170 +- 168/mm_3, and eosinophilia (more than 500/mm_3) had been observed in 11 cases (5.5%). Postirradiation eosinophilia occurred in 126 cases (63%). The mean period between institution of irradiation and the peak of the eosinophil count was 27.8 days. The mean highest eosinophil count was 691 +- 437/mm_3, and the mean bone marrow dose in this period was 906 rad. Comparisons of the eosinophil count according to the stage showed no significant differences. (Chiba, N.).

1982-01-01

326

Electron-impact excitation of Si"3"+(3s#->#3p) using a merged-beam electron-energy-loss technique  

International Nuclear Information System (INIS)

For the first time, absolute cross sections for electron-impact excitation of a multiply charged ion have been measured using an electron-energy-loss technique. Cross sections for e+Si"3"+(3s "2S_1_/_2)#->#e+Si"3"+(3p "2P_1_/_2_,_3_/_2)-8.88 eV have been measured with an accuracy of #+-#20% (at 90% confidence level) over a narrow energy range (#+-#0.6 eV) about the threshold energy with an energy resolution of 0.2 eV. Results are in good agreement with close-coupling calculations.

327

Dynamical evolution of a scalar field coupling to Einstein's tensor in the Reissner-Nordstroem black hole spacetime  

International Nuclear Information System (INIS)

We study the dynamical evolution of a scalar field coupling to Einstein's tensor in the background of a Reissner-Nordstroem black hole. Our results show that the coupling constant #eta# imprints in the wave dynamics of a scalar perturbation. In the weak coupling, we find that with the increase of the coupling constant #eta# the real parts of the fundamental quasinormal frequencies decrease and the absolute values of imaginary parts increase for fixed charge q and multipole number l. In the strong coupling, we find that for l#not =#0 the instability occurs when #eta# is larger than a certain threshold value #eta#_c which deceases with the multipole number l and charge q. However, for the lowest l=0, we find that there does not exist such a threshold value and the scalar field always decays for arbitrary coupling constant.

2010-10-15

328

Dynamic neuronal ensembles: Issues in representing structure change in object-oriented, biologically-based brain models  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the structure of dynamic neuronal ensembles (DNEs). DNEs represent a new paradigm for learning, based on biological neural networks that use variable structures. We present a computational neural element that demonstrates biological neuron functionality such as neurotransmitter feedback absolute refractory period and multiple output potentials. More specifically, we will develop a network of neural elements that have the ability to dynamically strengthen, weaken, add and remove interconnections. We demonstrate that the DNE is capable of performing dynamic modifications to neuron connections and exhibiting biological neuron functionality. In addition to its applications for learning, DNEs provide an excellent environment for testing and analysis of biological neural systems. An example of habituation and hyper-sensitization in biological systems, using a neural circuit from a snail is presented and discussed. This paper provides an insight into ...

1996-12-31

329

Development of a small scintillation detector with an optical fiber for fast neutrons  

International Nuclear Information System (INIS)

To investigate the characteristics of a reactor and a neutron generator, a small scintillation detector with an optical fiber with ThO_2 has been developed to measure fast neutrons. However, experimental facilities where "2"3"2Th can be used are limited by regulations, and S/N ratio is low because the background counts of this detector are increase by alpha decay of "2"3"2Th. The purpose of this study is to develop a new optical fiber detector for measuring fast neutrons that does not use nuclear material such as "2"3"2Th. From the measured and calculated results, the new optical fiber detector which uses ZnS(Ag) as a converter material together with a scintillator have the highest detection efficiency among several developed detectors. It is applied for the measurement of reaction rates generated from fast neutrons; furthermore, the absolute detection efficiency of this detector was obtained experimentally.

2011-02-01

330

Delayed neutron yields: Time dependent measurements and a predictive model  

Energy Technology Data Exchange (ETDEWEB)

The delayed neutrons from neutron-induced fission in /sup 232/U, /sup 237/Np, /sup 238/Pu, /sup 241/Am, /sup 242/Am/sup m/, /sup 245/Cm, and /sup 249/Cf were studied for the first time; those from /sup 232/Th, /sup 233/U, /sup 235/U, /sup 238/U, /sup 239/Pu, /sup 241/Pu, and /sup 242/Pu were measured again. The data were used to develop an expression for the prediction of the absolute delayed neutron yield, and the prediction of delayed neutron emission with time. This approach accurately predicts observed delayed neutron yields and decay characteristics. A fission product yield model was used in conjunction with delayed neutron emission probability to analytically predict delayed neutron characteristics. The results of this analysis are in excellent agreement with experimental values.

1981-03-01

331

Current waste-management practices and operations at Oak Ridge National Laboratory, 1982  

Energy Technology Data Exchange (ETDEWEB)

The need for efficient management of industrial chemical wastes, especially those considered hazardous or radioactive, is receiving increased attention in the United States. During the past five years, several federal laws have addressed the establishment of stronger programs for the control of hazardous and residual wastes. At a facility such as Oak Ridge National Laboratory (ORNL), an efficient waste management program is an absolute necessity to ensure protection of human health and compliance with regulatory requirements addressing the treatment and disposal of hazardous, nonhazardous, and radioactive wastes. This report highlights the major regulatory requirements under which the Laboratory must operate and their impact on ORNL facilities. Individual waste streams, estimates of quantities of waste, and current waste management operations are discussed.

1982-09-01

332

Carbon dioxide adsorption on carbon nanomaterials  

British Library Electronic Table of Contents (United Kingdom)

The adsorption of CO2 on a number of activated carbons, thermal carbon black, and oxide materials at 195 K was studied using static and dynamic techniques. The landing surface areas ?(CO2) ? 0.19 nm2 on thermal carbon black and the absolute values of sorption for P/P 0 < 0.4 were determined. The density of adsorbed CO2 in the micropore volume was estimated at ?(CO2) = 0.91 g/cm3. It was demonstrated that the previously found effect of a weakening of the sorption interaction of nitrogen molecules with thin-walled materials (which manifested itself in an analysis of sorption isotherms by a comparative method) was pronounced to a lesser degree for the sorption of CO2. At the same time, the presence of supermicropores in activated carbon samples resulted in overestimated values of surface area...

2010-01-01

333

Bioprocess control from a multivariate process trajectory.  

Science.gov (United States)

A multivariate bioprocess control approach, capable of tracking a pre-set process trajectory correlated to the biomass or product concentration in the bioprocess is described. The trajectory was either a latent variable derived from multivariate statistical process monitoring (MSPC) based on partial least squares (PLS) modeling, or the absolute value of the process variable. In the control algorithm the substrate feed pump rate was calculated from on-line analyzer data. The only parameters needed were the substrate feed concentration and the substrate yield of the growth-limiting substrate. On-line near-infrared spectroscopy data were used to demonstrate the performance of the control algorithm on an Escherichia coli fed-batch cultivation for tryptophan production. The controller showed good ability to track a defined biomass trajectory during varying process dynamics. The robustness of the control was high, despite significant external disturbances on the ...

2003-09-05

334

Bilateral but not Unilateral Testicular Hypotrophy Predicts for Severe Impairment of Semen Quality in Men with Varicocele Undergoing Infertility Evaluation  

British Library Electronic Table of Contents (United Kingdom)

ObjectivesVaricocele is a common cause of infertility, and varicocele-associated testicular hypotrophy has been described as a potential cause of decreased semen quality. We investigated the relationship between testicular hypotrophy and poor semen quality in infertile men with varicoceles. We hypothesized that bilateral hypotrophy is required before the semen quality is severely impaired.MethodsWe retrospectively identified consecutive patients with palpable varicoceles undergoing an infertility evaluation at a single academic center. Each patient was evaluated by the same clinician with history and physical examination. Testicular hypotrophy was defined as a size discrepancy of greater than 3 mL or an absolute size of less than 14 mL. Multivariate logistic regression analysis was used to...

2008-01-01

335

Assessment of periodic sub-diurnal Earth rotation variations at tidal frequencies through transformation of VLBI normal equation systems  

British Library Electronic Table of Contents (United Kingdom)

We present an empirical model for periodic variations of diurnal and sub-diurnal Earth rotation parameters (ERPs) that was derived based on the transformation of normal equation (NEQ) systems of Very Long Baseline Interferometry (VLBI) observing sessions. NEQ systems that contain highly resolved polar motion and UT1-TAI with a temporal resolution of 15?min were generated and then transformed to the coefficients of the tidal ERP model to be solved for. To investigate the quality of this model, comparisons with empirical models from the Global Positioning System (GPS), another VLBI model and the model adopted by the conventions of the International Earth Rotation and Reference Systems Service (IERS) were performed. The absolute coefficients of these models agree almost completely within 7.5?...

2011-01-01

336

Absolute subcriticality measurement without calibration and detection efficiency dependence by the /sup 252/Cf source-driven noise method  

Energy Technology Data Exchange (ETDEWEB)

The /sup 252/Cf-source-driven noise analysis method determines the subcriticality of a system containing fissionable material from the ratio of cross power spectral densities between the detectors that detect particles from the fission process and between these detectors and an ionization chamber containing a spontaneously fissioning neutron source which provides neutrons to induce fission in the system. This method has two advantages: (1) a calibration is not required and thus subcriticality can be determined from measurements only on the subcritical system of interest, and (2) the subcriticality is independent of the type of detector or its efficiency. These properties of this technique are illustrated by measurements.

1984-01-01

337

A note on the examination of isospin effects in multi-dimensional Langevin fission dynamics  

British Library Electronic Table of Contents (United Kingdom)

In [W. Ye, F. Wu, H.W. Yang, Phys. Lett. B 647 (2007) 118] prescission protons and ? particles of high-isospin 206Pb were shown to be almost independent of the dissipation strength Formula Not Shown . Subsequently, in [P.N. Nadtochy, et al., Phys. Lett. B 685 (2010) 258] prescission light charged particles (LCPs) were shown to have approximately the same sensitivity as neutrons to Formula Not Shown for 206Pb and 204Hg nuclei. In this Letter we point out that the reason for the apparent contradictory conclusions is that the authors in the latter did not compute the changes in the absolute yields of prescission LCPs multiplicities with increasing Formula Not Shown and compare them with typical experimental uncertainties. It is shown that the expected changes are very small in the case of ne...

2011-01-01

338

A diffusion criterion of the crystal-liquid phase transition  

Science.gov (United States)

A diffusion criterion of the crystal-liquid phase transition (PT) is proposed according to which the PT begins when the E d/ k b ratio reaches a threshold value of E d( s)/ k b T m, where E d is the self-diffusion energy, k B is the Boltzmann constant, T is the absolute temperature, and E d( s) is the self-diffusion energy in the solid phase at the melting temperature T m. It is shown that this criterion is a generalization of the Lindemann criterion and is applicable both to solids exhibiting normal melting and to those melting with a decrease in the specific volume. Based on the new criterion, it is possible to explain the relation T N < T m, where T N, is the crystallization onset temperature. The results of calculations of the T N/ T m ratio well coincide with experimental data.

2007-10-01

339

A brief historical development of classical mathematics before the Renaissance  

British Library Electronic Table of Contents (United Kingdom)

'If you wish to foresee the future of mathematics our proper course is to study the history and present condition of the science.' Henri Poincare 'It is India that gave us the ingenious method of expressing all numbers by ten symbols, each symbol receiving a value of position, as well as an absolute value. We shall appreciate the grandeur of the achievement when we remember that it escaped the genius of Archimedes and Apollonius.' P.S. Laplace 'The Greeks were the first mathematicians who are still 'real' to us today. Oriental mathematics may be an interesting curiosity, but Greek mathematics is the real thing. The Greek first spoke of a language which modern mathematicians can understand.' G.H. Hardy This article deals with a short history of mathematics and mathematical scientists during...

2011-01-01

340

Dosimetry measurements of x-ray and neutron radiation levels near the shuttle and end beam dump at the advanced test accelerator: Beam Research Program  

International Nuclear Information System (INIS)

Electron beams as a source of directed energy are under study at the Lawrence Livermore National Laboratory (LLNL). An intense 10-kA, 50-MeV, 50-ns full-width half-maximum, pulsed electron beam is generated by the prototype Advanced Test Accelerator (ATA) at the Laboratory's Site 300. Whenever the electron beam is stopped in materials, intense radiation is generated. Estimates based on available data in the literature show that for materials such as lead, photon radiation (x ray, gamma, bremsstrahlung) levels can be as large as 10"4 roentgens per pulse at 1 m in the zero-degree direction (i.e., the electron-beam direction). Neutrons, which are emitted isotropically, are produced at a level of 10"1"3 n/m"2 per pulse. Depending upon the number of pulses and the shielding geometry, the accumulated dose is potentially lethal to personnel and potentially damaging to instrumentation that may be used for diagnostics. To provide shielding for minimizing the risk of exposure to personnel and ...

341

Dosimetry for Total Skin Electron Beam Therapy in Skin Cancer  

International Nuclear Information System (INIS)

Increasing frequency of skin cancer, mycosis fungoides, Kaposi sarcoma etc, it need to treatment dose planning for total skin electron beam (TSEB) therapy. Appropriate treatment planning for TSEB therapy is needed to give homogeneous dose distribution throughout the entire skin surface. The energy of 6 MeV electron from the 18 MeV medical linear accelerator was adapted for superficial total skin electron beam therapy. The energy of the electron beam was reduced to 4.2 MeV by a 0.5cmx90cmx180cm acryl screen placed in a feet front of the patient. Six dual field beam was adapted for total skin irradiation to encompass the entire body surface from head to toe simultaneously. The patients were treated behind the acryl screen plate acted as a beam scatterer and contained a parallel-plate shallow ion chamber for dosimetry and beam monitoring. During treatment, the patient was placed in six different positions due to be homogeneous dose distribution for whole skin around ...

1992-06-01

342

Cellular dosimetry: Absorbed fractions for monoenergetic electron and alpha particle sources and S-values for radionuclides uniformly distributed in different cell compartments  

Energy Technology Data Exchange (ETDEWEB)

The importance of cellular dosimetry in both diagnostic and therapeutic nuclear medicine is becoming increasingly recognized. Experimental range-energy relations for electrons and alpha particles, along with derived geometric reduction factors, are used to calculate cellular absorbed fractions for these radiations. The resulting absorbed fractions are employed to calculate cellular S-values for several radionuclides. Cellular absorbed fractions for monoenergetic electron sources with energies ranging from 0.1 keV to 1 MeV, distributed uniformly in the source region, are calculated for several target {l_arrow} source combinations including cell{l_arrow}cell, cell{l_arrow}cell surface, nucleus{l_arrow}nucleus, nucleus {l_arrow}cytoplasm and nucleus {l_arrow}cell surface. Similar data are also provided for monoenergetic alpha particle sources with energies ranging from 3 to 10 MeV. S-values are also conveniently tabulated for {sup 32}P, {sup 35}S, {sup 86}Rb, {sup ...

1994-02-01

343

The National Shipbuilding Research Program, 1992 Ship ...  

Science.gov (United States)

... Development Document for Proposed Effluent Limitations Guidelines and Standards for the Shipbuilding and Repair Point Source Category (Draft ...

1992-09-01

344

Replication in the Harp File System  

Science.gov (United States)

... i3a. ... gives performance measurements for various benchmarks, and compares the performance of Harp with the standard implementation of NFS in ...

1981-07-01

345
347

NI\\SI\\ - NASA Technical Reports Server  

Science.gov (United States)

A calorimeteric method for determining total hemispherical emittance of ... the standard deviation in the total hemispherical emittance value ...

348

MILSTRIP. MILitary, STandard, Requisitioning and Issue ...  

Science.gov (United States)

... Release/Receipt Document I&S Interchangeability and Substitutability ISSP Inter-Service Supply Support Procedures JANAP J

1987-05-01

349

Key comparison BIPM.RI(I)-K2 of the air-kerma standards of the ARPANSA and the BIPM in low-energy X-rays  

International Nuclear Information System (INIS)

A key comparison has been made between the air-kerma standards of the ARPANSA and the BIPM in the low-energy X-ray range. The results show the standards to be in agreement at the level of the combined standard uncertainty of 7.0 parts in 10"3 for the 10 kV radiation quality and 3.7 parts in 10"3 for all other beam qualities. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database. (authors)

2010-12-01

350

Handbook of Soviet Reinforced Plastics,  

Science.gov (United States)

... Soviet standard or specification number for each reinforced plastic is included ... The tabular data contains general applications of reinforced plastics. ...

1973-03-31

351
352

Evaluation of the properties of S235JR structural carbon steel in Lebanon  

International Nuclear Information System (INIS)

author.The chemical and mechanical properties of S235jr structural low carbon mild steel were tested and reported for specimens collected from the Lebanese steel market. European and American standards were presented as references and compared with the achieved results. Discussion was conducted to show the similarities and differences between S235JR steel samples and standard requirements. Some of the reasons for such differences were discussed. A database was furnished through this work for the public and mainly for the Lebanese Standard Organization LIBNOR to easily adopt and implement a standard that has been tested in Lebanon concerning the hot rolled low carbon structural steels

355

Carotid Artery Stenting Outcomes in the Standard Risk Population for Carotid Endarterectomy  

Science.gov (United States)

Carotid Artery Disease; Stroke; Amaurosis Fugax; Transient Ischemic Attack (TIA)

2011-10-03

356

Standardization charts for cost-benefit analysis of biogas systems: case study in Jordan  

Energy Technology Data Exchange (ETDEWEB)

This paper establishes a standardization procedure in which results are presented in ready-to-use charts for the economic evaluation of biogas plants. It is hoped this work will alleviate controversial reports on cost-effectiveness of biogas systems. Also, it is found that these systems are the most economic among renewable energy systems using a standardized procedure for their comparison augmented by the generated spider diagrams wherein most probable costing production values for each system are directly compared. (author).

1990-01-01

357

Standard deviation of measurement results in x-ray fluorescence spectrometry  

International Nuclear Information System (INIS)

The standard deviation of measurement results of a given element in XRF spectrometry depends on three factors: concentration and concentration region, atomic number and matrix. The effects of these factors were investigated by an XRF instrument type ARL 72.000 for aluminium metal, bauxite-red mud and aluminium using computerized data processing. A comparison of linear and nonlinear relation between concentration and the result of XRF analysis was made for the determination of standard deviation. (R.P.).

1984-11-13

358

Plume spread and atmospheric stability  

Energy Technology Data Exchange (ETDEWEB)

The horizontal spread of a plume in atmospheric dispersion can be described by the standard deviation of horizontal direction. The widely used Pasquill-Gifford classes of atmospheric stability have assigned typical values of the standard deviation of horizontal wind direction and of the lapse rate. A measured lapse rate can thus be used to estimate the standard deviation of wind direction. It is examined by means of a large dataset of fast wind measurements how good these estimates are. (author) 1 fig., 2 refs.

1999-08-01

359

Learning Effect and Standardization Effect in NPP's Construction  

International Nuclear Information System (INIS)

This paper describes the learning effect and standardization effect in the nuclear power construction, analyses their influence degree on nuclear power economics. Furthermore, the paper provides the ideas on how to improve the economics of nuclear power through implementing the learning effect and standardization effect. The paper also concludes that the learning rate in China is better than the average value in the world by analysis actual example. (authors)

2009-09-01

360

High-level waste storage tank farms/242-A evaporator Standards/Requirements Identification Document (S/RID), Volume 2  

Energy Technology Data Exchange (ETDEWEB)

The High-Level Waste Storage Tank Farms/242-A Evaporator Standards/Requirements Document (S/RID) is contained in multiple volumes. This document (Volume 2) presents the standards and requirements for the following sections: Quality Assurance, Training and Qualification, Emergency Planning and Preparedness, and Construction.

1994-04-01

361

Evaluating the metrology of the standard method of determining blast furnace coke strength  

Science.gov (United States)

Coke strength increases in significance as blast furnace and metallurgical plant gain in size and output requirement. The article underlines the need to apply error computation standards to strength testing routines. The mean square deviation was found for cokes from different plants, related to a single strength determination for M25 and M10, and amounted to 0.61 and 0.35% respectively. The future standards should include a correlation factor for permitted tolerance as between parallel determinations.

1981-03-01

362

Environmental assessment for the proposed effluent limitations guidelines, pretreatment standards, and new source performance standards for the centralized waste treatment industry  

Science.gov (United States)

This report assesses the water quality related benefits that would be expected if the US Environmental Protection Agency (EPA) adopts the proposed effluent limitations, guidelines and pretreatment standards for the Centralized Waste Treatment (CWT) Industry. EPA estimates that under baseline conditions 205 CWT facilities discharge approximately 5.22 million lbs/year of metal and organic pollutants.

1998-12-01

363

Economic-impact analysis of proposed effluent-limitations guidelines, new source performance standards and pretreatment standards for the pulp, paper and paperboard mills. Point source category. Volume 2. Detailed description of product sectors  

Energy Technology Data Exchange (ETDEWEB)

This study analyzes the economic impact that could result from the application of effluent standards and limitations issued under Sections 301, 304, 306, 307 of the Clean Water Act to the pulp, paper, and paperboard industry, including builders' paper and roofing felt manufacturing.

1980-12-01

364

Determination of lead in soil samples by "2"0"3Pb radioisotope dilution substoichiometric method  

International Nuclear Information System (INIS)

A procedure for the determination of lead in soil samples by "2"0"3Pb radioisotope dilution substoichiometric method is described. Japan NIES No.2 river clay standard sample and 83-40 Tibet soil standard sample were determined. The obtained values were in good agreement with reference values. The standard deviation of the method was less then 5%. Detection limit was about 0.1 #mu#g Pb.

365

Cost-effectiveness analysis of final effluent limitations guidelines and standards of performance for the offshore oil and gas industry  

International Nuclear Information System (INIS)

The EPA proposed effluent limitations guidelines and standards for the offshore segment of the oil and gas industry on August 26, 1985. On November 26, 1990, and March 13, 1991, the Agency reproposed effluent limitations guidelines and standards for both drilling and production wastes. The report is primarily concerned with the total annualized cost incurred by the offshore oil and gas industry in complying with the regulations.

1993-01-01

366

Cost-effectiveness analysis of effluent standards and limitations for battery manufacturing  

Energy Technology Data Exchange (ETDEWEB)

The document reports the results of a cost-effectiveness analysis of alternative water pollution control regulations of the battery manufacturing industry. These regulations include effluent limitations and standards based on best practical control technology currently available, best available technology economically achievable, and pretreatment standards for new sources. For each of these regulations, EPA has identified several pollution control options, each with different levels of pollution abatement and compliance cost. The analysis is a tool for evaluating the options.

1984-02-01

367

American National Standard: design basis for protection of light water nuclear power plants against effects of postulated pipe rupture  

Energy Technology Data Exchange (ETDEWEB)

This standard addresses the design bases for light water reactor, nuclear power plant structures and components essential for the protection of public health and safety from the potential adverse effects of pipe whip, jet impingement, pressurization of compartments outside containment, environmental conditions and flooding associated with a postulated pipe rupture. The design bases for missile protection and the design bases for containment pressurization are not within this standard.

1980-12-31

368

Non-standard antineutrino interactions at Daya Bay  

CERN Document Server

We study the prospects of pinning down the effects of non-standard antineutrino interactions in the source and in the detector at the Daya Bay neutrino facility. It is well known that if the non-standard interactions in the detection process are of the same type as those in the production, their net effect can be subsumed into a mere shift in the measured value of the leptonic mixing angle theta_13. Relaxing this assumption, the ratio of the antineutrino spectra measured by the Daya Bay far and near detectors is distorted in a characteristic way, and good fits based on the standard oscillation hypothesis are no longer viable. We show that, under certain conditions, three years of Daya Bay running can be sufficient to provide a clear hint of non-standard neutrino physics.

2011-01-01

369

Major roles of water chemistry for safe and reliable nuclear power plant operation. Research committee on water chemistry standard  

International Nuclear Information System (INIS)

The research committee of the Atomic Energy Society of Japan on water chemistry standard aims at establishing the private standard of water chemistry of nuclear power plants. The committee gathers up 'BWR water chemistry management manual', 'PWR primary system water chemistry management manual' and 'PWR water chemical analysis standard method', and furthermore aims at the standardization of those in future. Looking back on the committee's activities for the past four years, latest results of research of water chemistry mainly contributing to safe and reliable nuclear power plants were described with the future perspective of water chemistry and a demanded break-through. (T.T.)

2007-05-01

370

Economic-impact analysis of effluent limitations and standards for the battery-manufacturing industry  

Energy Technology Data Exchange (ETDEWEB)

The report identifies and analyzes the economic impacts of water pollution control regulations on the battery manufacturing industry. These regulations include effluent limitations and standards based on BPT (best practical control technology currently available), BAT (best available technology economically achievable), PSES (pretreatment standards existing sources), NSPS (new source performance standards), and PSNS (pretreatment standards new sources), that have been promulgated under authority of Sections 301, 304, 306, 307, 308, and 501 of the Federal Water Pollution Control Act, as Amended (the Clean Water Act). The primary economic impact variables of interest include price changes, plant closures, substitution effects, changes in employment, shifts in the balance of foreign trade, changes in industry profitability, structure, and competition, and impacts on small business.

1984-01-01

371

Transport and superconducting properties of RNi_2B_2C (R=Y, Lu) single crystals  

International Nuclear Information System (INIS)

The in-plane resistivity, in-plane absolute thermopower, and upper critical field measurements are reported for single-crystal samples of YNi_2B_2C and LuNi_2B_2C superconductors. The in-plane resistivity shows metallic behavior and varies approximately linearly with temperature near room temperature (RT) but shows nearly quadratic behavior in temperature at low temperatures. The YNi_2B_2C and LuNi_2B_2C single-crystal samples exhibit large transverse magnetoresistance (#approx#6 8% at 45 kOe) in the ab plane. The absolute thermopower S(T) is negative from RT to the superconducting transition temperature T_c. Its magnitude at RT is a few times of the value for a typical good metal. S(T) is approximately linear in temperature between #approx#150 K and RT. Extrapolation to T=0 gives large intercepts (few #mu#V/K) for both samples suggesting the presence of a much larger knee than would be expected from electron-phonon interaction renormalization ...

372

Reduced resolution polarimetric imagery characterization of the 1990 Galveston Bay oil spill  

Energy Technology Data Exchange (ETDEWEB)

Low resolution visual polarimetric photographic imagery of the Galveston Bay oil spill from a tanker accident on July 28, 1990 was obtained and analyzed. The low resolution imagery (30 to 100 meters) was obtained concurrently with high resolution (1 meter), and is representative of what would be seen by a polarimetric satellite. Orthogonal red-green-blue (RGB) polarimetric images obtained with color photography were digitized by KODALUX on to a CD ROM. These polarimetric images were then used to calculate the percent polarization. The positive and negative percent polarized radiation scattered by each of the sea surface waves is seen individually in high resolution imagery. (Percent polarization is defined as positive when the dominant radiation is perpendicular to the plane of incidence and negative when it is parallel). The analysis of low resolution polarimetry is approached in a different manner than high resolution; in high resolution, individual waves are imaged and the ...

1997-06-01

373

Phenomenological analysis of heavy hadron lifetimes  

International Nuclear Information System (INIS)

A phenomenological analysis of lifetimes of bottom and charmed hadrons within the framework of the heavy quark expansion is performed. The baryon matrix element is evaluated using the bag model and the nonrelativistic quark model. We find that bottom-baryon lifetimes follow the pattern #tau#(#OMEGA#_b)#approx =##tau#(#XI#_b"-)>#tau#(#LAMBDA#_b)#approx =##tau#(#XI#_b"0). However, neither the lifetime ratio #tau#(#LAMBDA#_b)/#tau#(B_d) nor the absolute decay rates of the #LAMBDA#_b baryon and B mesons can be explained. One way of solving both difficulties is to allow the presence of linear 1/m_Q corrections by scaling the inclusive nonleptonic width with the fifth power of the hadron mass m_H__Q rather than the heavy quark mass m_Q. The hierarchy of bottom baryon lifetimes is dramatically modified to #tau#(#LAMBDA#_b)>#tau#(#XI#_b"-)>#tau#(#XI#_b"0)>#tau#(#OMEGA#_b): The longest-lived #OMEGA#_b among bottom baryons in the OPE prescription now becomes the ...

374

IMRT verification by three-dimensional dose reconstruction from portal beam measurements  

International Nuclear Information System (INIS)

A method of reconstructing three-dimensional, in vivo dose distributions delivered by intensity-modulated radiotherapy (IMRT) is presented. A proof-of-principle experiment is described where an inverse-planned IMRT treatment is delivered to an anthropomorphic phantom. The exact position of the phantom at the time of treatment is measured by acquiring megavoltage CT data with the treatment beam and a research prototype, flat-panel, electronic portal imaging device. Immediately following CT imaging, the planned IMRT beams are delivered using the multiple-static field technique. The delivered fluence is sampled using the same detector as for the CT data. The signal measured by the portal imaging device is converted to primary fluence using an iterative phantom-scatter estimation technique. This primary fluence is back-projected through the previously acquired megavoltage CT model of the phantom, with inverse attenuation correction, to yield an input fluence map. The input fluence maps are ...

2002-08-01

375

Clinical studies on cancer of the tongue  

Energy Technology Data Exchange (ETDEWEB)

Thirty-nine previously untreated patients with squamous cell carcinoma of the tongue were treated by irradiation or a combination of irradiation and surgery, with or without chemotherapy, between January 1971 and December 1980. All of the patients had a follow-up period of at least nine years. Twenty-two patients were men and 17 were women. The average age was 50.1 years, with a range of 30 to 74 years. The absolute five-year survival rate was 82.1% and the cumulative ten-year survival rate 76.9% for these 39 patients. Cervical node metastases were clinically found on admission in 14 patients whose five-year survival rate was 64.3%, whereas it was 92.0% for 25 patients without metastasis. The absolute five-year survival rate decreased from 92.3% for patients with stage I lesions to 90.9%, 87.5% and 42.9% for those with stage II, stage III and stage IV lesions, respectively. Most of the patients received external irradiation and intraoral ...

1990-12-01

376

CO{sub 2} bands in the 3350 - 3700 cm{sup {minus}1} spectral region: Ro-vibrational constants and absolute intensities  

Energy Technology Data Exchange (ETDEWEB)

Spectroscopic constants and absolute intensities from more than 2150 transitions belonging to 52 bands of 7 isotopic species of carbon dioxide have been determined using a multispectrum nonlinear least-squares fitting technique. The spectral data (0.01 cm{sup -1} resolution) were obtained at room temperature and low pressure (<10 Torr) using the McMath-Pierce Fourier transform spectrometer of the National Solar Observatory on Kitt Peak, Arizona. A natural sample of carbon dioxide with absorption path lengths between 24 and 385m were used in recording the spectra. The first measurements have been made of the theoretically predicted 2v{sub 2}{sup 2} 2+v{sub 3} {open_quotes}forbidden{close_quotes} band of {sup 12}CO{sub 2}. Two bands which have not been predicted so far, one belonging to {sup 13}CO{sub 2} and the other to {sup 13}C{sup 16}O{sup 18}O, have been identified. The measured line intensities obtained for each band have been analyzed to determine the ...

1995-12-31

377

Standards for limits of air pollutant emission in the GDR  

Energy Technology Data Exchange (ETDEWEB)

Activities of the Referenzlaboratorium Reinhaltung der Luft at Magdeburg as well as existing air pollution standards in the German Democratic Republic are reviewed. The laboratroy coordinates research and standardization in the field of industrial air pollution for the Ministry of Health. The standards provide orientation for emission control by state district health inspectorates. Emission limits (in g/m/sup 3/) which are international standards for 15 selected industries are listed. Emission limits (in g/m/sup 3/) of GDR standards, issued between 1971 and 1984 are also provided. They concern emission of brown coal dust from coal preparation plants, dust and chemical compound emission from metallurgical plants, dust emission from plants of the limestone and cement industry as well as from cupola furnace plants, boiler plants, plants of the wood industry and road asphalt mixing. Six ...

1986-01-01

378

Realized and projected impacts of U.S. federal efficiency standards for residential appliances  

Energy Technology Data Exchange (ETDEWEB)

This study estimated energy, environmental and consumer economic impacts of U.S. Federal residential energy efficiency standards that became effective in the 1988-2001 period or will take effect by the end of 2007. These standards have been the subject of in-depth analyses conducted as part of DOE's standards rulemaking process. This study drew on those analyses, but updated certain data and developed a common framework and assumptions for all of the products. We estimate that the considered standards will reduce residential primary energy consumption and CO{sub 2} emissions in 2020 by 8-9% compared to the levels expected without any standards. They will save a cumulative total of 25-30 quads by the year 2015, and 60 quads by 2030. The estimated cumulative net present value of consumer benefit amounts to nearly $80 billion by 2015, and grows to $130 billion by 2030. The ...

2002-06-01

379

ASTM residential green building standard guide development  

Energy Technology Data Exchange (ETDEWEB)

The authors have led development of a Standard Guide for Residential Green Buildings through the consensus process of the American Society for Testing and Materials (ASTM). The voluntary guidance document has been processed through two public peer reviews in ASTM`s E-50.06 sub-committee on the environment. The guide`s purpose is to present general criteria for home builders, residential designers and developers on how to systematically approach the creation of a green home--from the design phase on through to eventual de-commissioning of residential structures. This paper briefly reviews the standards process, includes an overview of the Standard Guides` principal criteria, and provides a robust resource listing for further investigation by readers. During development of the Standard Guide, authors emphasized thorough review of the available literature on sustainable residential development. This was ...

1997-12-31

380

Development of American National Standard on External Event PRA Methodology  

International Nuclear Information System (INIS)

During the last ten years, the U.S. Nuclear Regulatory Commission and the U.S. nuclear utilities have been developing methods and requirements for risk-informed applications making use of probabilistic risk assessments (PRA) of nuclear power plants. Early in this process, it became clear that the existing PRAs were done with different objectives and methodologies by different analysts. For uniformity and consistency in future risk-informed applications, industry consensus standards on probabilistic risk assessments were deemed to be essential. Currently, the following standards have been published or under preparation: - ASME RA-S-2002: 'Standard for Probabilistic Risk Assessment for Nuclear Power Plant Applications', Addendum C, March 2005. - ANSI/ANS-58.21-2003 'External-Events PRA Methodology' March 2003. - ANS-58.22 'Low Power and Shutdown PRA Standard'. - ANS-58.23 'Fire PRA Methodology ...

2007-11-14

381

The response of some TL albedo neutron dosimeters  

International Nuclear Information System (INIS)

As part of a general study of personnel neutron dosimetry systems, three British and two German TL albedo dosimeters were compared. They range from simple albedo devices to multi-element devices which detect combinations of incident and albedo neutrons. They were exposed to beams of mono-energetic neutrons, a thermal neutron column and a "2"5"2Cf source. The variation in response with neutron energy above 0.1 MeV was similar for all dosimeters. The resuls show that in general multi-component dosimeters fo not provide enough information to deduce the effective energy of incident neutrons. The choice of single or multi-element dosimeters for particular types of environment is discussed. The Harvey dosimeter has the most acceptable thermal neutron response of the simpler devices. For neutron energies below 0.5 MeV its response varies roughly as the cosine of the angle of incidence but is more complex at higher energies. (author).

382

The integral experiment on beryllium with D-T neutrons for verification of tritium breeding  

Energy Technology Data Exchange (ETDEWEB)

A clean benchmark experiment on beryllium was performed with D-T neutrons at the FNS facility of the Japan Atomic Energy Agency. The main objective was to verify the integral data related to the tritium production on lithium isotopes. Tritium production rates, as well as activation reaction rates were measured inside the beryllium assembly that was shaped as a pseudo-cylindrical slab with an area-equivalent diameter of 628 mm and a thickness of 355 mm. Experimental results were analyzed with a three-dimensional Monte Carlo transport code MCNP-4C and FENDL/MC-2.0, JENDL-3.2/3.3 neutron transport libraries. Evaluation of reaction rates was based on the cross section data taken from the JENDL Dosimetry File and ENDF B-VI data libraries. Analysis shows that all calculation combinations (transport and activation cross section libraries) used for evaluation of reaction rates give data that is agreeable with measured values within 10%.

2007-01-15

383

TLD array for precise dose measurements in stereotactic radiation techniques  

International Nuclear Information System (INIS)

We developed a new TLD array for precise dose measurement and verification of the spatial dose distribution in small radiation targets. It consists of a hemicylindrical, tissue-equivalent rod made of polystyrene with 17 parallel moulds for an exact positioning of each TLD. The spatial resolution of the TLD array was evaluated using the Leskell spherical phantom. Dose planning was performed with KULA 4.4 under stereotactic conditions on axial CT images. In the Leksell gamma unit the TLD array was irradiated with a maximal dose of 10 Gy with an unplugged 14 mm collimator. The doses delivered to the TLDs were rechecked by diode detector and film dosimetry and compared to the computer-generated dose profile. We found excellent agreement of our measured values, even at the critical penumbra decline. For the 14 mm and 18 mm collimator and for the 11 mm collimator combination we compared the measured and calculated data at full width at half maximum. This TLD array may be ...

1996-12-01

384

Spectral energy effects in ESR bone dosimetry: photons and electrons  

International Nuclear Information System (INIS)

The spectral energy-dependence of the radiation-induced ESR signal has been studied in ovine cortical bone. Crushed bone samples were irradiated using photon beams with effective energies in the range from 0.06 to 6 MeV, and electron beams with mean energies in the range from 2 to 10 MeV. The photon and electron data were normalized to a dose to bone of 50 Gy and the results are reported as response relative to the ESR signal for photon irradiation at 1.25 MeV ("6"0Co). The photon irradiation results show that the ESR response is greatest at low energies with a relative value of 1.2 at 0.06 MeV. The relative response decreases, as the energy increases, to approximately 0.85 in the region of 2 to 3 MeV. These variations in the relative ESR responses are significantly less than the ESR energy-dependent responses reported in the literature for human tooth enamel and synthetic hydroxyapatite. An explanation for this difference is offered. For electron beam irradiations, the ESR signal is ...

385

Role of accelerator mass spectrometry in biological dosimetry  

International Nuclear Information System (INIS)

Understanding risks from exposures to carcinogens and other chemicals depends upon measurement of their dose to target tissues and their reactivity with critical macromolecules. The authors have used AMS detection of radio-isotopes to assess doses and reactivities at low, environmentally relevant doses. Several biomedical investigations show the effectiveness of quantification of biologically important events at extremely high sensitivity with AMS. Specifically, they have measured the addition of environmental carcinogens such as 2-amino-3,8-dimethylimidazo[4,5-f]-quinoaxaline (MelQx), a chemical found in cooked food, to DNA at concentrations relevant to human exposure. Other low level detection problems in biology, such as immunoassay assessment of small environmental chemicals, is being developed with attomole sensitivity. AMS also aids the assessment of genotoxic risks from chemicals by quantifying the binding of labeled chemicals to DNA. The very toxic and potent carcinogen, ...

1992-04-05

386

Radiological concepts in radiotherapy  

International Nuclear Information System (INIS)

The atomic explosions in Hiroshima and Nagasaki made the name radiation itself become a nightmare. Notwithstanding this, radiation continued to serve the mankind specially in diagnosis of several human diseases and in the treatment of intractable malignancies. With their latest research tools biologists have now shown a significant shift in the earlier paradigm; even the concept that radiation initiates cancer appears to be no longer tenable. On the contrary, selective radiation doses inhibit growth of cancer cells and radiation in combination with many chemotherapeutic drugs, radiosensitizing chemicals and/or hyperthermia, is emerging as a new modality for cancer treatment which offers high therapeutic advantages. In addition, the deleterious effects of radiation can now be strategically counter poised by the use of many drugs and chemicals. This has been possible by the newer insights gained in the mechanism of biological effects of radiation. The fate of radiation-induced free ...

387

Quantitative assessment of cancer risk from exposure to diesel engine emissions  

Energy Technology Data Exchange (ETDEWEB)

Quantitative estimates of lung cancer risk from exposure to diesel engine emissions were developed using data from three chronic bioassays with Fischer 344 rats. Human target organ dose was estimated with the aid of a comprehensive dosimetry model. This model accounted for rat-human differences in deposition efficiency, normal particle clearance rates, transport of particles to lung-associated lymph nodes, respiration rates, and lung surface area, as well as high-dose inhibition of particle clearance. Recent evidence indicates that the inert carbon core of the diesel particulate matter is likely to be the primary source of carcinogenicity. The epithelial tissue lining the alveoli and lower airways is the primary target site for induction of lung tumors. Dose was therefore based upon the concentration of carbon particulate matter per unit lung surface area. Unit risk estimates were developed using either a time-to-tumor or a linearized multistage model. The unit ...

1993-02-01

388

Preliminary study of the application of natural olivine in Cenozoic dating  

Energy Technology Data Exchange (ETDEWEB)

The study investigated the luminescence behaviour of natural olivine to discuss the potential for Cenozoic (quaternary) dating. The UV-blue thermoluminescence (TL) glow curves of irradiated olivines have a resolved peak at 190 deg. C and other peaks at higher temperature at lower dose levels, and broad signals around 275-310 and 375-400 deg. C at higher dose levels. The UV-blue TL increases with additional laboratory dose to {approx}1.6kGy within a plateau temperature region, suggesting the possibility of dosimetry and Cenozoic dating. Both infrared stimulated luminescence (IRSL) and blue light stimulated luminescence (BLSL) were detected from laboratory-irradiated olivines although the BLSL was weaker than the IRSL. Furthermore, post-BL IRSL was detected but post-IR BLSL was not observed. Therefore, IR stimulation is recommended for optically stimulated luminescence measurements with natural olivine. The growth of the IRSL signal component with doses less than ...

2006-08-15

389

Physics of electron beam therapy  

International Nuclear Information System (INIS)

A book has been written to introduce the physical aspects of the radiotherapy electron beam by presenting a summary of the developments in this field. The first chapter is a brief introduction to the technology of medical accelerators with emphasis on the electron beam production facilities. Chapter 2 describes the interaction processes at the atomic level once the electron beam enters the medium. Chapter 3 is concerned with the various properties of the electron beam purely from the clinical point of view. The electron beam algorithms and models for distribution calculations are covered in Chapter 4 with inclusion of age diffusion and multiple scattering approaches. The factors affecting the beam distribution in a patient, with inhomogeneities, surface irregularities, backscattering etc. are discussed in Chapter 5. The last two chapters are devoted to electron beam dosimetry including various dosimetric methods, specification and measurement of beam energy, ...

390

Pet's research at the SHFJ, Cea, one example: development and validation of a radioligand for the study of the cerebral dopaminergic system; La recherche en TEP au SHFJ, CEA. Un exemple: developpement et validation de radioligands pour l'etude du systeme dopaminergique  

Energy Technology Data Exchange (ETDEWEB)

The aim of this work is the evaluation of biodistribution and radiation dosimetry of a cocaine analog, the N-(3-iodo-prop-2E-enyl)-2beta-carbo-methoxy-3beta-(4-methyl-phenyl) nor-tropane (PE2I), labeled with carbon 11 ([{sup 11}C]PE2I). The [{sup 11}C]PE2I is a selective radioligand for imaging neuronal dopamine transporter (DAT) with positron emission tomography (PET). The DAT is a membrane-bound pre synaptically located protein that regulates the concentration of dopamine at nerve terminals. DAT radioligands are often used to evaluate the progression of Parkinson's disease or the efficiency of neuro-protective therapeutics and, typically, these studies required several successive PET scans. (author)

2005-10-15

391

Measurement of dose-area product in diagnostic radiology as a method of assessing the radiation exposure. (Results, experience, proposals for improvement, recommendations relating to radiological protection). Report of an expert meeting  

International Nuclear Information System (INIS)

The fundamental recommendations of the ICRP issued in its publication of 1990 stipulate the general principle of performance of dose measurements at regular intervals in the field of diagnostic radiology, for the purpose of equipment performance checking and optimization of radiological protection. In response to this requirement, the Federal Ministry, in cooperation with experts and the competent supervising authorities, has issued an order to install dose-area-product meters in angiographic examination systems, imaging systems and fluoroscopic screen devices primarily used for examining infants and children up to the age of 12. This is done in response to reported cases of adverse effects of radiation exposure and the high priority given to radiological protection in the examination of infants and children. In 1992, an expert group was convened to discuss and elaborate instructions for including dose-area product measurement in the dosimetry activities in medical ...

392

Irradiation of food  

International Nuclear Information System (INIS)

Processing of food with ionizing radiation is a method suitable to enhance shelf-life and hygienic quality. Up to a dose of 10 kGy the method is considered wholesome. In many countries the practical use of food irradiation is increasing, however, in the Federal Republic of Germany the process is strictly forbidden. Applications and methods for radiation processing of food are compiled, limits and prospects are explained, and advantages and disadvantages are compared with traditional methods. Identification of irradiated foods and dosimetry and process control for radiation processing of food are areas where further research is needed. Continuous processing of particulate foods in bulk is an application where electron accelerators might be profitable. Beam parameters and velocity distribution of food particles in the treatment area can be matched for an effective result. Thus, dose distribution can be adjusted for homogeneous treatment and at the same time radiation ...

393

Intensity-Modulated Radiation Therapy with Noncoplanar Beams for Treatment of Prostate Cancer in Patients with Bilateral Hip Prosthesis-A Case Study  

International Nuclear Information System (INIS)

Megavoltage photon intensity-modulated radiation therapy (IMRT) is typically used in the treatment of prostate cancer at our institution. Approximately 1% to 2% of patients with prostate cancer have hip prostheses. The presence of the prosthesis usually complicates the planning process because of dose perturbation around the prosthesis, radiation attenuation through the prosthesis, and the introduction of computed tomography artifacts in the planning volume. In addition, hip prostheses are typically made of materials of high atomic number, which add uncertainty to the dosimetry of the prostate and critical organs in the planning volume. When the prosthesis is bilateral, treatment planning is further complicated because only a limited number of beam angles can be used to avoid the prostheses. In this case study, we will report the observed advantages of using noncoplanar beams in the delivery of IMRT to a prostate cancer patient with bilateral hip prostheses. The ...

2010-01-01

394

Facility Effluent Monitoring Plan for Pacific Northwest National Laboratory Balance-of-Plant Facilities  

Energy Technology Data Exchange (ETDEWEB)

The Pacific Northwest National Laboratory (PNNL) operates a number of research and development (R and D) facilities for the Department of Energy on the Hanford Site. According to DOE Order 5400.1, a Facility Effluent Monitoring Plan is required for each site, facility, or process that uses, generates, releases, or manages significant pollutants or hazardous materials. Three of the R and D facilities: the 325, 331, and 3720 Buildings, are considered major emission points for radionuclide air sampling and thus individual Facility Effluent Monitoring Plans (FEMPs) have been developed for them. Because no definition of ''significant'' is provided in DOE Order 5400.1 or the accompanying regulatory guide DOE/EH-0173T, this FEMP was developed to describe monitoring requirements in the DOE-owned, PNNL-operated facilities that do not have individual FEMPs. The remainder of the DOE-owned, PNNL-operated facilities are referred to as Balance-of-Plant (BOP) ...

1999-04-02

395

Extremely low frequency electric and magnetic fields and cancer: A literature review  

Energy Technology Data Exchange (ETDEWEB)

Epidemiologic studies suggest a weak link between occupational or residential exposure to extremely low frequency electromagnetic fields and cancer, especially tumors of the central nervous and hematopoietic systems. This report discusses these studies with reference to basic research on ELF EMF bioeffects relevant to cancer-promoting mechanisms. Many of the studies suggest a possible interaction of ELF EMF with the immune system, endocrine system, or growth-regulatory signals and morphogenic movements that involve calcium flux through cell membranes. Many bioeffects have been reported only with certain specific combinations of frequency, amplitude, and orientation of the EMF signal with respect to the geomagnetic field. The possibility of signal-specific effects raises a complication in dosimetry for both epidemiologic and experimental studies since ELF EMF effects may not be directly related to field strength. The report concludes with a discussion of design ...

1989-12-01

396

Dosimetry in dental radiology. Dentascan spiral CT versus panoramic radiography; Dosimetria nella radiologia odontostomatologica: confronto tra tomografia computerizzata spirale e ortopantomografia  

Energy Technology Data Exchange (ETDEWEB)

The study compares the doses absorbed by the dentomaxillary area in spiral CT and panoramic examinations. The dose measurements demonstrate that patients receive smaller doses with panoramic radiography than with spiral CT with Dentascan. After following for some variations from instrumental differences, they are in substantial agreement with literature data. Further investigations are needed considering the radiobiological risk related to the growing spread of Dentascan examinations. [Italian] Questo lavoro intende confrontare le dosi assorbite nel distretto dento-mascellare, con le due principali tecniche utilizzate in questo campo: TC spirale e ortopantomografia. Emerge come l'esame panoramico delle arcate dentarie eseguito con l'ortopantomografo comporti la'ssorbimento di dosi inferiori rispetto a quelle dell'esame TC spirale con programma Dentascan. Questi dati, pur essendo soggetti a variabilita' dovuta alla strumentazione utilizzata, ...

1999-05-01

397

Dosimetry characterization of $^{32}$P intravascular brachytherapy source wires using Monte Carlo codes PENELOPE and GEANT4  

CERN Document Server

Monte Carlo calculations using the codes PENELOPE and GEANT4 have been performed to characterize the dosimetric parameters of the new 20 mm long catheter based $^{32}$P beta source manufactured by Guidant Corporation. The dose distribution along the transverse axis and the two dimensional dose rate table have been calculated. Also, the dose rate at the reference point, the radial dose function and the anisotropy function were evaluated according to the adapted TG-60 formalism for cylindrical sources. PENELOPE and GEANT4 codes were first verified against previous results corresponding to the old 27 mm Guidant $^{32}$P beta source. The dose rate at the reference point for the unsheathed 27 mm source in water was calculated to be $0.215 \\pm 0.001$ cGy s$^{-1}$ mCi$^{-1}$, for PENELOPE, and $0.2312 \\pm 0.0008$ cGy s$^{-1}$ mCi$^{-1}$, for GEANT4. For the unsheathed 20 mm source these values were $0.2908 \\pm 0.0009$ cGy s$^{-1}$ mCi$^{-1}$ and $0.311 \\pm 0.001$ cGy s$^{-1}$ mCi$^{-1}$, ...

2003-01-01

398

Dosimetric properties of an applicator system for intraoperative electron-beam therapy utilizing a Clinac--18 accelerator  

International Nuclear Information System (INIS)

A prototype electron applicator system providing circular and rectangular fields for use in intraoperative electron beam therapy with a Varian Clinac 18 linear accelerator has been fabricated. The dosimetric properties of this system for a variety of electron-beam energies, applicator sizes, and x-ray collimator settings was documented. Significant findings include: (a) surface dose values are in excess of 90% for electron energies of 12 MeV and above; (b) for the 18-MeV beam, the deepest depth where the central axis dose is 90% of its maximum value is in excess of 50 mm for circular applicators whose diameters are in excess of 5 cm; and (c) the treatment time to deliver 1000 rads ''given dose'' (at a given dose rate of 300 MU/min) is on the order of 3--4 min. Cross-field behavior is acceptable for the intended application and x-ray contamination is less than 4% for any applicator/electron energy combination. A system for irregular field blocking and TLD verification ...

399

Development of real time personal neutron dosimeter with two silicon detectors  

Energy Technology Data Exchange (ETDEWEB)

The personal neutron dosimetry becomes more important with the increasing use of nuclear and accelerator facilities. The solid state track detector, film badge and thermo-luminescent dosimeter have widely been used as passive-type personal neutron dosimeters, but the real-time neutron dosimeter is strongly needed. A real time personal dosimeter which could give neutron dose equivalent over wide energy range from thermal to 10 odd MeV by using two neutron sensors has been developed by our group. For practical commercial product, some changes from these prototype sensors have recently been done by Fuji Electric Co. Ltd. The purpose of this work is the final performance test of the dosimeter just before sale. We checked again about the sensitivity in the monoenergetic neutron field from 8 keV to 15 MeV and in the neutron fields around a few accelerator facilities. (author)

1997-07-01

400

DOE personnel neutron dosimetry evaluation and upgrade program  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy (DOE) sponsors an extensive research program to improve the methods, dosimeters, and instruments available to DOE facilities for measuring neutron dose and assessing its effects on the work force. The Total Dose Meter was recently developed for measuring in real time the adsorbed dose of mixed neutron and gamma radiation and for calculating the dose equivalent. The Field Neutron Spectrometer was developed to provide a portable instrument for determining neutron spectra in the workplace for flux-to-dose equivalent conversion and quality factor calculation. The Combination Thermoluminescence/Track Etch Dosimeter (TLD/TED) was developed to extend the effective neutron energy range of the conventional TLDs to improve detection of fast-energy neutrons. An Optically Stimulated Luminescence Dosimeter is presently being developed for application to gamma, neutron, and beta radiation. An Effective Dose Equivalent System is being developed to provide guidance in ...

1988-10-01

401

Computed tomography of the orbit  

Energy Technology Data Exchange (ETDEWEB)

In less than a decade computed tomography (CT scanning) had a profound impact on diagnostic radiology. Radiology of the orbit is no exception. As early as 1973, reports published in the radiological literature indicated that this new noninvasive imaging method was a highly effective way of demonstrating intraorbital mass lesions. As CT scanners became widely available, computed tomography became a significant adjunct to ophthalmological diagnosis. Today the main indications for CT scanning of the orbit are: (1) suspected mass lesions, most frequently presenting as exophthalmos, (2) orbital trauma, including foreign bodies, (3) some congenital anomalies, and (4) suspicion of extension into the orbit of extraorbital disease processes. Along with ultrasonography, another new noninvasive imaging technique, CT has replaced a number of more invasive and often less effective diagnostic methods, such as orbital pneumography, venography, and arteriography as major imaging techniques in orbital ...

1981-01-01

402

Comparison of radon exposure assessment results: {sup 210}Po surface activity on glass objects vs. contemporary air radon concentration  

Energy Technology Data Exchange (ETDEWEB)

Radon exposure assessment in case-control studies on radon and lung cancer is generally based on contemporary radon concentration measurements, which can be affected by significant changes in the building structures or in living habits. Another method to estimate the radon exposure of the subjects is the recently developed retrospective dosimetry technique based on the {sup 210}Po surface activity from glass objects. In order to compare the results obtained by the two methods, a study has been carried out in a sample of 26 dwellings in Rome, with radon concentration values ranging from 28 to 623 Bq m{sup -3}. Retrospective detectors based on CR-39 and LR 115 were exposed on 50 glass objects in bedrooms and living rooms. The correlation factor between the two sets of data, after removing six extreme values, is 0.67, which is similar to results obtained in other validation studies of similar sample size. The correlation increases to 0.83 if the 21 objects exposed in ...

2003-06-01

403

Characterization of Radiation Instruments at the Summit of Mt. Fuji  

International Nuclear Information System (INIS)

The opportunity of exposure to high-energy radiation up to GeV is increasing as in civilian aircrafts and at particle accelerators. The transport of such energetic particle is still difficult to describe precisely and thus verification by measurement using a well characterized instrument is indispensable for reliable dosimetry. However, no reference calibration field has been established for the high-energy range. We thus propose to use a facility at the summit of Mt. Fuji (3776 m in altitude; N35.36o, E138.73o), the highest place in Japan, for characterization of radiation instruments that are possibly used in high-energy radiation fields. For demonstration of the effectiveness, two moderator-type neutron monitors (NCN1 and WENDI-II) having different energy response functions were employed for cosmic-ray neutron measurements in the summer of 2009. In comparison with numerically simulated values, it was found that the extended energy neutron monitor (WENDI-II) has ...

2010-12-01

404

Analysis on Dose Distribution in Heterogeneous Condition for Narrow 6 MV X-ray Beams  

International Nuclear Information System (INIS)

Advanced modality of high-precision radiotherapy fulfilled by a composition of large numbers of small field beams called 'beamlets' can be achieved via nonuniform intensity fluencies. In case of radiation measurements and calculations with narrow high-energy photon beams, however, an accurate two-dimensional dosimetry is a challenging task due to dosimetrically unfavorable phenomena such as dramatic changes of the dose at the field boundaries, dis-equilibrium of the electrons resulting from larger detector volume, and non-uniformity between the detector and the phantom materials. Meanwhile, with the advantages of high spatial resolution and wide range of absorbed doses, there is a growing demand of GAFCHROMICat..EBT film to confirm delivered dose distribution. Especially, the effects from the material differences between the phantom and the film can be minimized in the heterogeneous condition since the GAFCHROMICat..EBT film is composed of tissueequivalent ...

2010-10-01

405

APMP/TCRI key comparison report of measurement of air kerma for medium-energy x-rays (APMP.RI(I)-K3)  

Energy Technology Data Exchange (ETDEWEB)

The APMP/TCRI Dosimetry Working Group performed the APMP.RI(I)-K3 key comparison of measurement of air kerma for medium-energy x-rays (100 kV to 250 kV) between 2000 and 2003. In total, 11 institutes took part in the comparison, among which 8 were APMP member laboratories. Two commercial cavity ionization chambers were used as transfer instruments and circulated among the participants. All the participants established the 100 kV, 135 kV, 180 kV and 250 kV x-ray beam qualities equivalent to those of the BIPM. The results showed that the maximum difference between the participants and the BIPM in the medium-energy x-ray range, evaluated using the comparison data of the linking laboratories ARPANSA and PTB, is less than 1.4%. The degrees of equivalence between the participants are presented and this comparison confirms the calibration capabilities of the participating laboratories. (authors)

2008-10-15

406

AIDE: internal dosimetry software.  

Science.gov (United States)

AIDE (Activity and Internal Dose Estimates) is a software for calculating activities in compartments and committed doses due to occupational exposures, and for performing intake and dose estimates using bioassay data. It has been continuously developed and tested for more than 20 years. Its calculation core has been applied in several situations, like performing all dose estimates due to (137)Cs intakes, which occurred during the Goiania accident in 1987; performing quality assurance of the ICRP Task Group on Dose Calculations regarding calculations of activities in compartments and generation of dose coefficients for adults due to intakes by inhalation, ingestion and injection of several radionuclides; and producing the tables of activities in compartments and dose coefficients using the NCRP Wound Model for the NCRP report. It provides several capabilities like performing calculations using modified Human Respiratory Tract Model parameters for the mechanical transport, blood ...

2008-03-12

407

A study on the real-time radiation dosimetry measurement system based on optically stimulated luminescence  

Science.gov (United States)

The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous radiation occasions. Supported by National Natural Science Foundation of China (10475112), Western Light Foundation of Chinese Academy of Sciences of ...

2008-05-01

408

Land And Water Use Characteristics And Human Health Input Parameters For Use In Environmental Dosimetry And Risk Assessments At The Savannah River Site  

International Nuclear Information System (INIS)

Operations at the Savannah River Site (SRS) result in releases of small amounts of radioactive materials to the atmosphere and to the Savannah River. For regulatory compliance purposes, potential offsite radiological doses are estimated annually using computer models that follow U.S. Nuclear Regulatory Commission (NRC) Regulatory Guides. Within the regulatory guides, default values are provided for many of the dose model parameters but the use of site-specific values by the applicant is encouraged. A detailed survey of land and water use parameters was conducted in 1991 and is being updated here. These parameters include local characteristics of meat, milk and vegetable production; river recreational activities; and meat, milk and vegetable consumption rates as well as other human usage parameters required in the SRS dosimetry models. In addition, the preferred elemental bioaccumulation factors and transfer factors to be used in human health exposure calculations ...

409

Technical requirements for the ASME PRA standard for nuclear power plant applications  

Energy Technology Data Exchange (ETDEWEB)

In 1998 the American Society of Mechanical Engineers (ASME) formed the Committee on Nuclear Risk Management (CNRM) and a Project Team to develop a standard on PRAs for use in risk informed applications. This ASME standard is being developed to help provide an adequate level of quality in PRAs that are being used to support ASME initiatives to risk informed in-service inspection (ISI) and in-service testing (IST) of nuclear power plant components. A related need supported by the industry and the U.S. Nuclear Regulatory Commission is to reduce the level of effort that is being expended in pilot applications of risk informed initiatives to address questions about the sufficiency of quality in the supporting PRA models. The purpose of this paper is to discuss the authors' views on some of the technical issues that were encountered in the effort to develop the ASME PRA standard. Draft 12 of this ...

2000-07-01

410

Technical requirements for the ASME PRA standard for nuclear power plant applications  

International Nuclear Information System (INIS)

In 1998 the American Society of Mechanical Engineers (ASME) formed the Committee on Nuclear Risk Management (CNRM) and a Project Team to develop a standard on PRAs for use in risk informed applications. This ASME standard is being developed to help provide an adequate level of quality in PRAs that are being used to support ASME initiatives to risk informed in-service inspection (ISI) and in-service testing (IST) of nuclear power plant components. A related need supported by the industry and the U.S. Nuclear Regulatory Commission is to reduce the level of effort that is being expended in pilot applications of risk informed initiatives to address questions about the sufficiency of quality in the supporting PRA models. The purpose of this paper is to discuss the authors' views on some of the technical issues that were encountered in the effort to develop the ASME PRA standard. Draft 12 of this standard has ...

411

Standards for transport and storage components established by The Atomic Energy Society of Japan and The Japan Society of Mechanical Engineers  

Energy Technology Data Exchange (ETDEWEB)

Since June 1997 the standards/specifications and inspection/certification of various products in Japan have been reviewed by Ministries and Agencies, with the aim of reducing direct government intervention to a necessary minimum and creating a free and fair socio-economic system that is fully opened to the international community and based on the rules of self-responsibility and market principles. Reflecting this policy the administrative regulations which prescribe technical standards as specific requirements have been revised by degrees into performance prescriptions. Detailed provisions in ordinances and notices have been abolished gradually to utilize voluntary standards and rules. In the nuclear energy field voluntary standards are being developed to make up statutory performance requirements by the Atomic Energy Society of Japan (AESJ) and the Japan Society of Mechanical Engineers (JSME) together ...

2004-07-01

412

Monitoring processes and measuring the effectiveness of the management system  

International Nuclear Information System (INIS)

This document presents the way which the 8th principle of the quality management system 'Process approach' is applied, the principle that is identified and used by international standard ISO 9000. In order to understand the evolution of the management system requirements, as used today in different activities namely, industry, services, and nuclear activities, the authors present an evolution of the quality concept and its traceability to different standards, applicable in time. There are described the requirements of ISO 9001 standard, that represents the most widely spread model for modern organization management and the IAEA concerns related to integration of the above standard requirements into the most recent safety IAEA standard 'The Management System for facilities and activities'. The IAEA Safety Standard GS-R-3 describes a management model considering ...

2009-10-12

413

Improving system modeling accuracy with Monte Carlo codes  

International Nuclear Information System (INIS)

The use of computer codes based on Monte Carlo methods to perform criticality calculations has become common-place. Although results frequently published in the literature report calculated k_e_f_f values to four decimal places, people who use the codes in their everyday work say that they only believe the first two decimal places of any result. The lack of confidence in the computed k_e_f_f values may be due to the tendency of the reported standard deviation to underestimate errors associated with the Monte Carlo process. The standard deviation as reported by the codes is the standard deviation of the mean of the k_e_f_f values for individual generations in the computer simulation, not the standard deviation of the computed k_e_f_f value compared with the physical system. A more subtle problem with the standard deviation of the mean as reported by the codes is that all the k_e_f_f ...

1996-06-16

414

The effects of aircraft engine pollutant emission measurement variability on engine certification policy  

Science.gov (United States)

Divergence between aircraft engine emission regulations proposed by EPA and ICAO is discussed. Every engine, upon entering service, requires a certificate as to its compliance with emission standards. It is shown that despite the large variability in the measurements, it is possible to devise a certification procedure requiring the testing of one engine only. Statistical modeling of such a test at the 5% significance level is described. Values of the parameter standard deviation/mean recommended as certification standards for various pollutants are given. Features of a rational certification scheme to be formulated are outlined.

1978-10-01

415

System 80+trademark Standard Design: CESSAR design certification. Volume 16  

International Nuclear Information System (INIS)

This report has been prepared in support of the industry effort to standardize nuclear plant designs. This document describes the Combustion Engineering, Inc. System 80+trademark Standard Design. This volume contain Chapter 18 -- Human Factors Engineering. Topics covered include: design team organization and responsibilities; design goals and design bases; design process and application to human factors engineering; functional task analysis; control room configuration; information presentation and panel layout evaluation; control and monitoring outside the main control room; and verification and validation.

416

Report of the Beyond the Standard Model Working Group of the 1999 UK Phenomenology Workshop on Collider Physics (Durham)  

CERN Document Server

The Beyond the Standard Model Working Group discussed a variety of topics relating to exotic searches at current and future colliders, and the phenomenology of current models beyond the Standard Model. For example, various supersymmetric (SUSY) and extra dimensions search possibilities and constraints are presented. Fine-tuning implications of SUSY searches are derived. The implications of Higgs (non)-discovery are discussed, as well as the program HDECAY. The individual contributions are included seperately. Much of the enclosed work is original, although some is reviewed.

2000-01-01

417

NIST {sup 222}Rn emission standards  

Energy Technology Data Exchange (ETDEWEB)

NIST radon standards are hermetically sealed polyethylene capsules filled with {sup 226}Ra solution. Recently, four new series of standards with activities 5, 50, 500, and 5000Bq were prepared. The measured emanation fraction agrees with a calculation that accounts for the radon accumulated inside the polyethylene walls of the capsule. Obtained solubility of radon in polyethylene is approximately 45 of the solubility of radon in water. The radon diffusion coefficient in low-density polyethylene is 7.2x10{sup -8}cm{sup 2}/s.

2006-10-15

418

Ideal Magnetohydrodynamics Stability Spectrum with a Resistive Wall  

Energy Technology Data Exchange (ETDEWEB)

We show that the eigenvalue equations describing a cylindrical ideal magnetophydrodynamicsw (MHD) plasma interacting with a thin resistive wall can be put into the standard mathematical form: ??? = ??? ?. This is accomplished by using a finite element basis for the plasma, and by adding an extra degree of freedom corresponding to the electrical current in the thin wall. The standard form allows the use of linear eigenvalue solvers, without additional interations, to compute the complete spectrum of plasma modes in the presence of a surrounding restrictive wall at arbitrary separation. We show that our method recovers standard results in the limits of (1) an infinitely resistive wall (no wall), and (2) a zero resistance wall (ideal wall).

2008-05-22

419

Development document for proposed effluent limitations guidelines new source performance standards, and pretreatment standards for the coal mining point source category  

Energy Technology Data Exchange (ETDEWEB)

Technical Development Document supporting proposed water discharge regulations for the Coal Mining Industry authorized by the Clean Water Act. Proposed regulations include revised best practicable technology limitations, best available technology limitations and new source performance standards for the Coal Mining Industry. Industry operations include: coal preparation and amillary operations, active mining, F bituminous, anthracite and lignite coal, and the reclamation phase of mining.

1981-01-01

420

Comparison of Atmospheric Dispersion Models Between PHWR and PWR  

International Nuclear Information System (INIS)

The radiation dose and the atmospheric dispersion for Pressurized Heavy Water Reactors (PHWR) are based on the CAN/CSA N288.2-M91 standards: for Pressurized Water Reactor (PWR) on the NRC Regulatory Guide 1.145. There are some differences between in the methodologies used in the standards, including the atmospheric dispersion model, the release height, the temperature lapse rate, the cutoff condition. This paper reports on a comparison of standards for atmospheric dispersion models of PHWRs and PWRs in order to determine which one is the more conservative. The comparison between PHWR and PWR for atmospheric dispersion factors and radiation doses confirms that there are no big differences

2010-10-01

421

An overview of standards concerning unwanted electrostatic discharges  

British Library Electronic Table of Contents (United Kingdom)

For users and manufacturers affected by unwanted electrostatic discharges, the publication of standards concerning the control of such discharges is a great improvement and helps to prevent unwanted electrostatic discharges in potentially explosive atmospheres as well as around electrostatically sensitive devices. There are, for instance, handbook-like documents giving recommendations to help set up effective electrostatic suppressing measures and programs. Another group of standards focuses on certain products and processes and is, thus, more specific. A third group deals with test methods and specifications to help manufacturers develop products that are safe. It also helps in comparisons with other products and thus meets the customer's real needs. To assist manufacturers and customers ...

2009-01-01

422

Wireless connectivity for health and sports monitoring: a review  

UK PubMed Central (United Kingdom)

This is a review of health and sports monitoring research that uses or could benefit from wireless connectivity. New, enabling wireless connectivity standards are evaluated for their suitability, and...Full Text Available

2007-05-01

423

WIS (WWMCCS (Worldwide Military Command and Control ...  

Science.gov (United States)

... the print queue, changing the priority of print jobs, -deleting a job from a print queue, aborting a ... "standard terminal interface" should ... f. Stochastic 27 ...

1985-07-01

424

VIBRATION ISOLATION OF SATELLITE TAPE RECORDERS  

Science.gov (United States)

A standardized method of shock and vibration isolation for satellite tape recorders has been developed. Using readily avail- able components, the isolators ...

425

Tri-Service DoD Partnership Delivers Standard Product to ...  

Science.gov (United States)

... This coordinated proposal was presented to the Threat System Working Group (TSWG) (then called the Threat System Investment Working Group ...

2011-05-14

426

The National Shipbuilding Research Program Task S-20: A ...  

Science.gov (United States)

... The other standards in this group deal with heat exchangers, insulation, marking, valves, hydraulic cleanliness, storage of LPG, and centrifugal fire ...

1979-05-01

427

The Minimal Scale Invariant Extension of the Standard Model  

CERN Document Server

We perform a systematic analysis of an extension of the Standard Model that includes a complex singlet scalar field and is scale invariant at the tree level. We call such a model the Minimal Scale Invariant extension of the Standard Model (MSISM). The tree-level scale invariance of the model is explicitly broken by quantum corrections, which can trigger electroweak symmetry breaking and potentially provide a mechanism for solving the gauge hierarchy problem. Even though the scale invariant Standard Model is not a realistic scenario, the addition of a complex singlet scalar field may result in a perturbative and phenomenologically viable theory. We present a complete classification of the flat directions which may occur in the classical scalar potential of the MSISM. After calculating the one-loop effective potential of the MSISM, we investigate a number of representative scenarios and determine their scalar boson mass ...

2010-01-01

428

The International Reference Preparation of Erythropoietin*  

UK PubMed Central (United Kingdom)

The WHO Expert Committee on Biological Standardization authorized the National Institute for Medical Research to establish an International Reference Preparation of Erythropoietin on the basis of the...Full Text Available

1966-01-01

429

The Influence of Inert Particulate Material on the Properties of ...  

Science.gov (United States)

... Briefly, a standard detonator (normally the Scale 1 Gap Test Donor, comprising an exploding bridgewire to initiate a low density PETN pellet and ...

1984-05-01

431

The Assessment of Fracture Risk  

UK PubMed Central (United Kingdom)

Bone mineral density is considered to be the standard measure for the diagnosis of osteoporosis and the assessment of fracture risk. The majority of fragility fractures occur in patients with bone mineral...Full Text Available

2010-03-01

432

TIPS Creation in a Patient with Situs Inversus Totalis  

International Nuclear Information System (INIS)

We describe the successful creation of a transjugular intrahepatic portosystemic shunt (TIPS) in a patient with complete situs inversus using a simple modification of the standard TIPS technique.

2002-10-01

433

Study, Design and Fabricate a Cold Crucible System  

Science.gov (United States)

... to changes in some of the system parameters by means of figures which show the two standard isotherme and two slightly distorted isotherms. ...

1975-03-31

435

Spectral Analysis of Breast Cancer on Tissue Microarrays ...  

Science.gov (United States)

... Although cytologic evaluation of urine specimens is a standard Cesar Angeletti, MD ... 3. Rodriguez-Alonso A, Pita-Fernandez S, Gonzalez-Carrero J, ...

2005-04-01

436

Spatial Relationships between Drug Binding Sites on the ...  

Science.gov (United States)

... determination of the molar extinction coefficients, e, were measured by the Lowry method with native a-toxin as a standard. Binding Kinetics. ...

1987-10-15

437

Songbirds and the Revised Avian Brain Nomenclature  

UK PubMed Central (United Kingdom)

It has become increasingly clear that the standard nomenclature for many telencephalic and related brainstem structures of the avian brain is based on flawed once-held assumptions of homology...Full Text Available

2004-06-01

438

Recommendations for a proposed standard for performing systems analysis  

Science.gov (United States)

In August 1995, the Nuclear Regulatory Commission (NRC) issued a policy statement proposing improved regulatory decisionmaking by increasing the use of PRA [probabilistic risk assessment] in all regulatory matters to the extent supported by the state-of-the-art in PRA methods and data. A key aspect in using PRA in risk-informed regulatory activities is establishing the appropriate scope and attributes of the PRA. In this regard, ASME decided to develop a consensus PRA Standard. The objective is to develop a PRA Standard such that the technical quality of nuclear plant PRAs will be sufficient to support risk-informed regulatory applications. This paper presents examples recommendations for the systems analysis element of a PRA for incorporation into the ASME PRA Standard.

1998-08-01

439

Recommendations for a proposed standard for performing systems analysis  

Energy Technology Data Exchange (ETDEWEB)

In August 1995, the US Nuclear Regulatory Commission (NRC) issued a policy statement proposing improved regulatory decision making by increasing the use of probabilistic risk assessment (PRA) in all regulatory matters to the extent supported by the state-of-the-art in PRA methods and data. A key aspect in using PRA in risk-informed regulatory activities is establishing the appropriate scope and attributes of the PRA. In this regard, the American Society of Mechanical Engineers (ASME) decided to develop a consensus PRA standard. The objective is to develop a PRA standard such that the technical quality of nuclear plant PRAs will be sufficient to support risk-informed regulatory applications. The authors present example recommendations for the systems analysis element of a PRA for incorporation into the ASME PRA standard.

1998-12-31

440

Real-Time Stability and Control Derivative Extraction From F-15 - NASA  

Science.gov (United States)

and the estimated parameter covariance matrix is. 5. (25) where p in this case is the number of elements in the vector . The parameter standard errors, ?, ...

441

Questions and Answers on Changes to the Renewable Fuel Standard...  

Science.gov (United States)

fuel obligation under the RFS2 program for the production or importation of conventional jet fuel, RINs can be generated for renewable jet fuel. Is that right? A: As described in...

2011-08-18

443

Psychological Aspects of Widowhood and Divorce  

UK PubMed Central (United Kingdom)

Despite advances in standard of living of the population, the condition of widows and divorced women remains deplorable in society. The situation is worse in developing nations with their unique social,...Full Text Available

2009-01-01

444

Postfire soil burn severity mapping with hyperspectral image unmixing  

Science.gov (United States)

Sep 28, 2011... to assess the application of high resolution imagery for burn severity mapping and to compare it to standard burn severity mapping methods. ...

445

Percutaneous renal biopsy as an outpatient procedure.  

UK PubMed Central (United Kingdom)

Percutaneous renal biopsy (PRB) is a safe and effective tool in the diagnosis and management of renal disease. It is the gold standard for evaluating renal parenchymal disease. It is both useful for...Full Text Available

2004-09-01

446

Parenchyma-sparing pancreatectomies for benign or border-line tumors of the pancreas  

UK PubMed Central (United Kingdom)

Standard pancreatic resections, such as pancreaticoduodenectomy, distal pancreatectomy, or total pancreatectomy, result in an important loss of normal pancreatic parenchyma and may cause impairment...Full Text Available

2010-06-15

447

PRA In Design - NASA Technical Report Server (NTRS)  

Science.gov (United States)

developing a consensus PRA standard for non- associated guidance light water reactor applications that will address some aspects of PRA in design. ...

448

Neutrino Oscillations: from Standard and Non-standard Viewpoints  

CERN Document Server

In the standard model of neutrino oscillations, the neutrino flavor states are mixtures of mass-eigenstates, and the phenomena are well described by the neutrino mixing matrix, i.e., the PMNS matrix. I review the recent progress on parametrization of the neutrino mixing matrix. Besides that I also discuss on the possibility to describe the neutrino oscillations by a non-standard model in which the neutrino mixing is caused by the Lorentz violation (LV) contribution in the effective field theory for LV. We assume that neutrinos are massless and that neutrino flavor states are mixing states of energy eigenstates. In our calculation the neutrino mixing parts depend on LV parameters and neutrino energy. The oscillation amplitude varies with the neutrino energy, thus neutrino experiments with energy dependence may test and constrain the Lorentz violation scenario for neutrino oscillation.

2011-01-01

449

National Advisory Committee for Aeronautics 1956 - NASA Technical ...  

Science.gov (United States)

Watkins, Harry L. Runyan, and Donald S. Woolston. Standard AtmosphereTables and Data for Altitudes ...... By W. S. Hyler, E. D. Abraham, and H. J. Grover. ...

450

NASA Standard for Models ... - JPL Technical Reports Server - NASA  

Science.gov (United States)

Hemez9 on the Predictive Capability Maturity Model, and for their feedback on the CAS d uring a 2 007 technical interchange meeting in Albuquerque, NM. ...

451

Minimally Invasive Orthopedic Surgery: Arthroscopy  

UK PubMed Central (United Kingdom)

Arthroscopy, a minimally invasive alternative to standard open surgical techniques and now the most commonly performed orthopedic surgical procedure, was one of the greatest advances in orthopedic surgery...Full Text Available

2000-07-01

452

Low-range flowmeters for use with vacuum and leak standards  

Energy Technology Data Exchange (ETDEWEB)

Vacuum pressure standards of the orifice-flow type require known gas flows of 10/sup -6/ mol/s (10/sup -2/ atm cm/sup 3//s at 0 /sup 0/C) and less. Known gas flows can also be used to calibrate ''standard'' leaks by comparing the pressures generated when flows from the leak and the flowmeter are alternately passed through a constant conductance. Two constant-pressure, piston displacement flowmeters developed at the National Bureau of Standards are described that can generate flows between 10/sup -6/ and 10/sup -10/ mol/s with an estimated uncertainty of 0.8% to 2%. Comparisons of the flowmeters with alternate calibration techniques, and repeated low-range leak and vacuum gauge calibrations, have been used to confirm the estimated uncertainty and random errors of the flowmeter.

1987-05-01

453

Lemna paucicostata Hegelm. 6746  

UK PubMed Central (United Kingdom)

Photoautotrophic and mixotrophic growth of Lemna paucicostata Hegelm. 6746 (formerly Lemna perpusilla Torr. 6746) was investigated to establish standardized conditions...Full Text Available

1980-05-01

454

Job Performance Measurement in the Military: A Classification ...  

Science.gov (United States)

... AUTHOR(S) Kavanagh, MJ; Borman, WC,; Hedge, JW; Gould, RB i3a. ... 3.5 Performance Standards, Scale Characteristics, and Scale Development ...

1987-09-01

455

Immunological reagents  

UK PubMed Central (United Kingdom)

The need for material standards in the field of clinical immunology, together with the mode of operation of the combined World Health Organization/International Union of Immunological Societies programme...Full Text Available

1976-01-01

457

Exploratory Report Aluminium and Aluminium Compounds.  

Science.gov (United States)

The report contains general information on aluminium and aluminium compounds concerning the existing standards, emissions, exposure levels and effect levels. The document is to be considered as a first evaluation to be used for the national discussion dur...

1993-01-01

458

Evaluation of a Biometric Keystroke Typing Dynamics ...  

Science.gov (United States)

... i3a TYPT OF REPORT 13b TIME COVERED 14 DATE OF RF ... automation system when used in conjunction with other standard security measures. ...

1992-03-01

459

Evaluating concentration estimation errors in ELISA microarray experiments  

UK PubMed Central (United Kingdom)

BackgroundEnzyme-linked immunosorbent assay (ELISA) is a standard immunoassay to estimate a protein's concentration in a sample. Deploying ELISA in a microarray format permits simultaneous...Full Text Available

460

Environmental and Motion Data Obtained during the JLOTS ...  

Science.gov (United States)

... Distribution Unlimited: Approved for "i3a. ... 'he tide changes were obtained using the standard NOAA National Ocean Survey tide tables. ...

1983-09-01

461

Environmental Decision Memo for Food Contact Notification No. ...  

Science.gov (United States)

... Environmental Assessment of Proposed Effluent Limitations Guidelines and Standards for the Meat and Poultry Industry Point Source; EPA-821-B-01-008; US ...

462

Electronic Warfare Technology - Trends and Visions  

Science.gov (United States)

... I3a. -YPE OF REPORT T7b 7,ME COVEE 14 DATE OF REPORT (Year, Month. ... the addition of various materials to the standard flare in order to ...

1990-05-01

463

Electromagnetic Effects Requirements for Systems.  

Science.gov (United States)

This standard establishes requirements, verification criteria, and contractor tasks for electromagnetic effects protection of airborne, ground, and support systems. These effects include electromagnetic compatibility, electromagnetic interference, lightni...

1993-01-01

464

Effect of Registration on Cyclical Kinematic Data  

UK PubMed Central (United Kingdom)

Given growing interest in Functional Data Analysis (FDA) as a useful method for analyzing human movement data, it is critical to understand the effects of standard FDA procedures, including...Full Text Available

2010-08-26

465

EPA - Stormwater Discharges from Construction Activities  

Science.gov (United States)

discharges. Proposed Stormwater ELG from Construction Sites - EPA has proposed effluent limitations guidelines (ELGs) and new source performance standards (NSPS) to control...

2011-10-14

466

Diesel engine systems for underground coal mines  

Energy Technology Data Exchange (ETDEWEB)

This standard specifies requirements for the flameproofing and the limiting of surface temperature and exhaust emission control of diesel engine systems for use in underground coal mines.

1988-01-01

467

Derivation of an Extra-Large PASGT Helmet  

Science.gov (United States)

... The solution used on the size Large helmet war an arbitrary one; as discussed above, the developers added a standard deviation to ... 4 O. i3a: o.04. ...

1988-07-01

468

Construction cost impact analysis of the U.S. Department of Energy mandatory performance standards for new federal commercial and multi-family, high-rise residential buildings  

Energy Technology Data Exchange (ETDEWEB)

In accordance with federal legislation, the U.S. Department of Energy (DOE) has conducted a project to demonstrate use of its Energy Conservation Voluntary Performance Standards for Commercial and Multi-Family High-Rise Residential Buildings; Mandatory for New Federal Buildings; Interim Rule (referred to in this report as DOE-1993). A key requisite of the legislation requires DOE to develop commercial building energy standards that are cost effective. During the demonstration project, DOE specifically addressed this issue by assessing the impacts of the standards on (1) construction costs, (2) builders (and especially small builders) of multi-family, high-rise buildings, and (3) the ability of low-to moderate-income persons to purchase or rent units in such buildings. This document reports on this project.

1993-12-01

470

Computer Controlled MHD Power Consolidation and Pulse ...  

Science.gov (United States)

... is a standard in the utility industry which is used to study switching transients on power distribution networks and high-voltage transmission lines. ...

1990-08-01

471

Big bang nucleosynthesis  

Energy Technology Data Exchange (ETDEWEB)

A brief review of standard big bang nucleosynthesis theory and the related observations of the light element isotopes is presented. Implications of BBN on chemical evolution and constraints on particle properties will also be discussed.

2000-01-01

472

Battalion Tactical Plays--Can They Increase Combat Power  

Science.gov (United States)

... Tactical plays are more than drills or standard operating proc-edures. ... IN * BYPMASS OR BREECH MINEFIELD ON FLANK SIXE (TM I3A C1 10 ...

1988-11-10

473

Avenger Team Performance During Engagement Operations ...  

Science.gov (United States)

... MOPP I3A f. Kl Figure 12. ... Table 13 contains the means, standard deviations, and number of observations for both clothing conditions. ...

1993-06-01

474

An overview of the medical informatics curriculum in medical schools.  

UK PubMed Central (United Kingdom)

As medical schools incorporate medical informatics into their curriculum the problems of implementation arise. Because there are no standards regarding a medical informatics curriculum, medical schools...Full Text Available

1998-01-01

475

Advances in Statistical Methods for Substance Abuse Prevention Research  

UK PubMed Central (United Kingdom)

The paper describes advances in statistical methods for prevention research with a particular focus on substance abuse prevention. Standard analysis methods are extended to the typical research...Full Text Available

2003-09-01

476

AFO Public Meeting -- Seattle, WA Proceedings  

Science.gov (United States)

years I chaired a national committee drafting recommended standards for organic livestock production for the Organic Trade Association and had the opportunity to work with...

2003-01-06

477

A cost-utility analysis of open and endoscopic carpal tunnel release  

UK PubMed Central (United Kingdom)

BACKGROUNDOpen carpal tunnel release (OCTR) is the standard procedure for the surgical treatment of carpal tunnel syndrome. With the advent of minimally invasive surgery, endoscopic...Full Text Available

2006-01-01

478

A - Z Index : Environmental Energy Technologies Division  

Science.gov (United States)

Buildings Energy-Efficient Research Laboratories Energy Efficiency in Federal Facilities Energy Efficiency Standards Group Energy Efficient Windows Collaborative Energy &...

2011-07-15

479

VUV efficiency and radiant emittance characterization of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

The pure xenon dc positive column discharge has been characterized for various xenon pressures, currents, and discharge tube radii. The absolute output at the 147 nm resonance transition has been measured using two independent techniques to yield the radiant emittance at 147 nm (power per unit surface area). The efficiency of 147 nm production is obtained by combining the measured radiant emittance with the measured electrical power per unit length deposited in the gas. The radiant emittance and the efficiency are the two principle figures of merit for characterizing the discharge as a source of VUV radiation. It is observed that the trends in efficiency and radiant emittance change substantially when the discharge transitions from two-step electron impact excitation/ionization at higher pressures to single-step electron impact ionization at lower pressures. Modeling of the xenon positive column discharge yields radiant emittance and efficiency predictions that are ...

1996-12-31

480

The effect of the primary collimator and flattening filter on asymmetric fields for a Siemens PRIMUS linear accelerator  

CERN Document Server

Homogeneity for highly asymmetric fields has been studied for a Siemens PRIMUS linear accelerator. The flattening filter has a radius smaller than the primary collimator one, creating inhomogeneities that affect large fields in areas far from the collimator axis, and asymmetric fields with large offset. Profiles and absolute dose have been measured in fields with two jaws at maximal position (20 cm) and the other two at maximal overtravel (10 cm.), corresponding to 10 x 10 fields with extreme offset. Profiles have a remarkable gradient decreasing towards the beam edge, making these fields unsuitable for treatments. Results show that the design of the primary collimator and flattening filter assembly has direct consequences in homogeneity. This can have clinical consequences for treatments involving fields that include these inhomogeneous areas. Comparisons with the treatment planning system (Philips Pinnacle) calculations, that computes under the hypotheses of a ...

2005-01-01

481

Spherically bent crystal spectroscopy in laser-produced plasma  

International Nuclear Information System (INIS)

A curved crystal X-ray spectrographs of reflection type spherical geometry was required based on the Johann scheme. Due to their high efficiency and resolution, X-ray spectrographs of focusing spectrograph spatial resolution are suitable for detecting weak X-ray spectra in spectrometers for laser fusion research. Spherically bent mica crystal with a radius of curvature of 380 mm was used in the spectrometer. The Bragg angle of the crystal analyzer was 51 degree. The image plate was employed to obtain high spatial resolution and a narrow spectral band width, with an effective area of 30 mm x 80 mm. The designed optical path of the X-ray spectrometer beam was 980 mm long from the source to the crystal and the detector. The first experiment was carried out at the 20 J energy laser facility of Research Center of Laser Fusion, China Academy of Engineering Physics. X-ray spectra in an absolute intensity scale were obtained from Al laser-produced plasmas created by laser ...

2008-02-01

482

Somatic and genetic effects of small doses of ionizing radiations in man  

International Nuclear Information System (INIS)

Estimations on the somatic and genetic effects of small doses of ionizing radiations in Man have been proposed by the Advisory Committee on the Biological Effects of Ionizing Radiation, set up by the U.S. National Academy of Sciences. They have been published in an important report, issued in 1972, from which we briefly analyze here the Chapter dealing with the somatic effects. Small doses of raditions are expected to promote only carcinogenic effects. After a rapid survey of the human experience on which the estimations are based, as regards the latent period of cancers, the plateau region (period of high risk) and the absolute and relative risk expressed per rem, per 10"6 persons, per year, for leukaemia (having the highest risk) and for the ''other cancers''. These estimations were obtained by linear extrapolation to the 1 rem level from observations made after irradiation at relatively high dose levels and much higher dose-rates. This extrapolation procedure, ...

1976-01-01

483

Semiconductor properties and protective role of passive films of iron base alloys  

Energy Technology Data Exchange (ETDEWEB)

Semiconductor properties of passive films formed on the Fe-18Cr alloy in a borate buffer solution (pH = 8.4) and 0.1 M H{sub 2}SO{sub 4} solution were examined using a photoelectrochemical spectroscopy and an electrochemical impedance spectroscopy. Photo current reveals two photo action spectra that derived from outer hydroxide and inner oxide layers. A typical n-type semiconductor behaviour is observed by both photo current and impedance for the passive films formed in the borate buffer solution. On the other hand, a negative photo current generated, the absolute value of which decreased as applied potential increased in the sulfuric acid solution. This indicates that the passive film behaves as a p-type semiconductor. However, Mott-Schottky plot revealed the typical n-type semiconductor property. It is concluded that the passive film on the Fe-18Cr alloy formed in the borate buffer solution is composed of both n-type outer hydroxide and inner oxide layers. On the ...

2007-01-15

484

Semiconductor properties and protective role of passive films of iron base alloys  

International Nuclear Information System (INIS)

Semiconductor properties of passive films formed on the Fe-18Cr alloy in a borate buffer solution (pH = 8.4) and 0.1 M H_2SO_4 solution were examined using a photoelectrochemical spectroscopy and an electrochemical impedance spectroscopy. Photo current reveals two photo action spectra that derived from outer hydroxide and inner oxide layers. A typical n-type semiconductor behaviour is observed by both photo current and impedance for the passive films formed in the borate buffer solution. On the other hand, a negative photo current generated, the absolute value of which decreased as applied potential increased in the sulfuric acid solution. This indicates that the passive film behaves as a p-type semiconductor. However, Mott-Schottky plot revealed the typical n-type semiconductor property. It is concluded that the passive film on the Fe-18Cr alloy formed in the borate buffer solution is composed of both n-type outer hydroxide and inner oxide layers. On the other ...

2007-01-01

485

Review and Understanding of Screen-Printed Contacts and Selective-Emitter Formation: Preprint  

Energy Technology Data Exchange (ETDEWEB)

A comparison of the loss mechanisms in screen-printed solar cells relative to buried contact cells and cells with photolithography-defined contacts is presented in this paper. Model calculations show that emitter recombination accounts for about 0.5% absolute efficiency loss in conventional screen-printed cells with low-sheet-resistance emitters. Ohmic contact to high-sheet-resistance emitters by screen-printing has been investigated to regain this efficiency loss. Our work shows that good quality ohmic contacts to high sheet-resistance emitters can be achieved if the glass frit chemistry and Ag particle size are carefully tailored. The melting characteristics of the glass frit determine the firing scheme suitable for low contact resistance and high fill factors. In addition, small to regular Ag particles were found to help achieve a higher open-circuit voltage and maintain a low contact resistance. This work has resulted in cells with high fill factors (0.782) on ...

2004-08-01

486

Remnant of a "Wet" Merger: NGC 34 and Its Young Massive Clusters, Young Stellar Disk, and Strong Gaseous Outflow  

CERN Document Server

This paper presents new images and spectroscopy of NGC 34 (Mrk 938) obtained with the du Pont 2.5-m and Baade 6.5-m telescopes at Las Campanas, plus photometry of an HST archival V image. This Mv = -21.6 galaxy has often been classified as a Seyfert 2, yet recently published infrared spectra suggest a dominant central starburst. We find that the galaxy features a single nucleus, a main spheroid containing a blue central disk, and tidal tails indicative of two former disk galaxies. These galaxies appear to have completed merging. The remnant shows three clear optical signs that the merger was gas-rich ("wet") and accompanied by a starburst: (1) It sports a rich system of young star clusters, of which 87 have absolute magnitudes -10.0 > Mv > -15.4. Five clusters with available spectra have ages in the range 0.1-1.0 Gyr, photometric masses between 2x10^6 and 2x10^7 Msun, and are gravitationally bound young globulars. (2) The blue central disk appears to be ...

2007-01-01

487

Predictions of nitrogen oxides production in diffusion turbulent flames; Predictions de la production des oxydes d`azote dans les flammes turbulentes de diffusion  

Energy Technology Data Exchange (ETDEWEB)

The suitability of the turbulent combustion flamelets model in order to predict the index of NO{sub x} production in turbulent flames of hydrogen diffusion is analyzed. In the flamelet approach, the turbulent flame is equivalent to a group of laminar flames submitted to a mechanical stretching which generates a chemical disequilibrium. This effect can be described by the stretching or by the scalar dissipation ratio. A numerical modeling is performed in order to evaluate the advantages of both approaches and to compare the behaviour of the NO{sub x} emission index with the experiments of Chen and Driscoll. This study shows that predictions of NO{sub x} emission indexes have a correct behaviour with respect to the Damkoehler number only when the scalar dissipation ratio is used as a parameter to describe the chemical state outside equilibrium. Predictions of the flamelet models are improving when the Damkoehler number increases. On the other hand, the absolute ...

1996-12-31

488

Modeling of electricity consumption in the Asian gaming and tourism center - Macao SAR, People's Republic of China  

Energy Technology Data Exchange (ETDEWEB)

The use of electricity is indispensable to modern life. As Macao Special Administrative Region becomes a gaming and tourism center in Asia, modeling the consumption of electricity is critical to Macao's economic development. The purposes of this paper are to conduct an extensive literature review on modeling of electricity consumption, and to identify key climatic, demographic, economic and/or industrial factors that may affect the electricity consumption of a country/city. It was identified that the five factors, namely temperature, population, the number of tourists, hotel room occupancy and days per month, could be used to characterize Macao's monthly electricity consumption. Three selected approaches including multiple regression, artificial neural network (ANN) and wavelet ANN were used to derive mathematical models of the electricity consumption. The accuracy of these models was assessed by using the mean squared error (MSE), the mean squared percentage error ...

2008-05-15

489

Irradiation characteristics examination technology development of irradiated nuclear material and high burn-up fuels  

Energy Technology Data Exchange (ETDEWEB)

The research and development for the first year of the project are performed through specialization of researchers, information from aborad and international cooperation, securement of advanced nuclear technology, development and installation of test equipment, application of external man-power, establishment of advanced test techniques, and certified test method. 1. Absolute efficiency measurement examination technology development of gamma scanning system 2. Sample preparation technology development of SEM and EPMA for micro-structural observation and chemical composition analysis 3. Irradiated high burn-up nuclear fuel transportation and test for PWR 4. Development of hot cell examination techniques and equipment 5. Acquirement of KOLAS system. In addition to the project, the following activities are carried out as follows; - PIE of Hanaro fuel(KH99H-001) - PIE of U-Mo advanced nuclear fuel irradiated at Hanaro - PIE of Hi-MET advanced nuclear fuel irradiated at ...

2002-12-01

490

Interdiffusion of molybdenum in high-alloy austenitic CrNiMo(N)-steels. Chemische Diffusion von Molybdaen in hochlegierten austenitischen CrNiMo(N)-Staehlen  

Energy Technology Data Exchange (ETDEWEB)

The volume diffusion of Mo in austenitic CrNiMo(N)-steels was studied using the sandwich method. Accordingly the interdiffusion coefficients of Mo were found to be independent of its concentration for the given steel composition with 12 to 19 wt.% Cr, 12 to 16 wt.% Ni, 0 to 2 wt.% Mo and 0 to 0.27 wt.% N and within the temperature range from 1283 to 1523 K. The diffusivity of Mo is greater than that of Cr, Ni and Fe in such steels. The diffusion parameters of Mo are decreased by alloying addition of nearly 0.25 wt.% N in steel; possibly as a result of lattice expansion or increasing vacancy concentration caused by N. Small variations in Cr and Ni initial contents of examined specimens showed negligible effect on the absolut values of interdiffusion coefficients of Mo. (orig.).

1991-08-01

491

Improved eddy-current inspection for steam generator tubing  

Energy Technology Data Exchange (ETDEWEB)

Computer programs have been written to allow the analysis of different types of eddy-current probes and their performance under different steam generator test conditions. The probe types include the differential bobbin probe, the absolute bobbin probe, the pancake probe and the reflection probe. The generator test conditions include tube supports, copper deposits, magnetite deposits, denting, wastage, pitting, cracking and IGA. These studies are based mostly on computed values, with the limited number of test specimens available used to verify the computed results. The instrument readings were computed for a complete matrix of the different test conditions, and then the test conditions determined as a function of the readings by a least-squares technique. A comparison was made of the errors in fit and instrument drift for the different probe types. The computations of the change in instrument reading due to the defects have led to an inversion'' ...

1989-01-01

492

Equation of state of laser-shocked compressed iron; Equation d'etat du fer comprime par choc laser  

Energy Technology Data Exchange (ETDEWEB)

This thesis enters the field of highly compressed materials equation of state studies. In particular, it focuses on the case of laser shock compressed iron. This work indeed aims at getting to the conditions of the earth's core, comprising a solid inner core and a liquid outer core. The understanding of phenomena governing the core's thermodynamics and the geodynamic process requires the knowledge of iron melting line locus around the solid-liquid interface at 3.3 Mbar. Several experiments were performed to that extent. First, an absolute measurement of iron Hugoniot was obtained. Following is a study of partially released states of iron into a window material: lithium fluoride (LiF). This configuration enables direct access to compressed iron optical properties such as reflectivity and self-emission. Interface velocity measurement is dominated by compressed LiF optical properties and is used as a pressure gauge. Using a dual wavelength ...

2004-01-01

493

Electron-impact excitation of multiply-charged ions using energy loss in merged beams: e+Si"3"+(3s"2S_1_/_2)#->#e+Si"3"+(3p"2P_1_/_2_,_3_/_2)  

International Nuclear Information System (INIS)

For the first time absolute total cross sections for electron-impact excitation of a multiply-charged ion have been measured using an electron-energy-loss technique. Measurements were made near threshold for the process e + Si"3"+(3s"2S_1_/_2) #-># e+Si"3"+(3p"2P_1_/_2_,_3_/_2)-8.88 eV. The 10"-"1"5 cm"2 measured cross section agrees with results of 7-state close coupling calculations to better than the #+-#20% (90% CL) total uncertainty of the measurements. Convoluting the theoretical curve with a Gaussian energy distribution indicates an energy width of 0.15 < or approx. #DELTA#E < or approx. 0.20 eV. (orig.).

494

Determination of reactivity from power spectral density measurements with /sup 252/Cf. [LMFBR  

Science.gov (United States)

The theory of a method of determination of reactivity from power spectral density measurements with /sup 252/Cf and the results of experiments with a critical assembly mockup of a liquid-metal fast breeder reactor (LMFBR) and with uranium (93.2 wt % /sup 235/U) metal cylinders and a sphere are presented. This method of reactivity determination has an advantage over existing methods in that it determines the reactivity only from properties of the reactor at the subcritical state of interest and thus does not require a calibration near delayed criticality. In these experiments, the reactivity was varied by changing the fissile loading or the amount of neutron absorber inserted; for the LMFBR mockup, the reactivity varied to approximately 75 dollars subcritical, and for the uranium metal assemblies to approximately 30 dollars subcritical. These experiments verified for the first time the predictions of theory that could be tested in the measurements. This method has potential use in the ...

1978-04-01

495

Dependence of proton beam polarization on ion source transition configurations  

Energy Technology Data Exchange (ETDEWEB)

The polarization of extracted SATURNE II proton beam as a function of different ion source configurations was studied. Two distinct experiments were necessary for this purpose. In the first one, the left-right instrumental asymmetry of the beam polarimeter was determined using an unpolarized beam. In the second one this correction factor was applied to asymmetries measured with the beam from the polarized ion source in all polarization states. The measurements were carried out at the proton beam kinetic energy 0.80 GeV, where the pp-elastic scattering analyzing power is near its maximum. The results confirmed that the two so-called ``unpolarized states`` of the source were polarized to several percent, whereas the absolute values of the beam polarizations in the so-called ``polarized states`` were equal and opposite. It was observed that the hexapole lens of the ion source produced beam polarization in the absence of any transition. The beam polarization as a ...

1997-11-11

496

Correlation of mechanical properties with microstructure of Alloy 800 after annealing at 800 - 1000 "0C  

International Nuclear Information System (INIS)

The microstructures of so called high temperature alloys, which have been developed for service temperatures up to 800"0C, are not necessarily stable at higher temperatures. The mobility of alloying elements is very high in FeCrNi alloys at 950 "0C e.g. iron, chromium or nickel can diffuse up to 0.1 mm distance in one year, which is about a grain diameter. Interstitials like carbon or nitrogen show a four orders of magnitude higher diffusivity than the alloying elements. In addition, the carbon solubility in this type of alloy is reported to be very low. Therefore the alloys are supersaturated with carbon after heat treatment above 1100 "0C and water quenching although the absolute carbon content is very low. At service temperatures around 800"0C the solubility of carbon is still about one order of magnitude lower than at heat treatment temperature. This will lead, together with the high mobility of elements, to precipitation of carbides even after short times and ...

1981-05-01

497

Band parameters for III - V compound semiconductors and their alloys  

International Nuclear Information System (INIS)

We present a comprehensive, up-to-date compilation of band parameters for the technologically important III - V zinc blende and wurtzite compound semiconductors: GaAs, GaSb, GaP, GaN, AlAs, AlSb, AlP, AlN, InAs, InSb, InP, and InN, along with their ternary and quaternary alloys. Based on a review of the existing literature, complete and consistent parameter sets are given for all materials. Emphasizing the quantities required for band structure calculations, we tabulate the direct and indirect energy gaps, spin-orbit, and crystal-field splittings, alloy bowing parameters, effective masses for electrons, heavy, light, and split-off holes, Luttinger parameters, interband momentum matrix elements, and deformation potentials, including temperature and alloy-composition dependences where available. Heterostructure band offsets are also given, on an absolute scale that allows any material to be aligned relative to any other. [copyright] 2001 American Institute of ...

2001-06-01

498

Assessment of dose-time-effect surfaces for somatic late effects after low dose irradiation  

International Nuclear Information System (INIS)

Awaiting new data from RERF, an attempt was made to estimate the somatic risks of low doses of radiation for members of the German public. The new estimate follows closely the approach used in deriving the values published in the NIH Radioepidemiological Tables. The lifetime risk factors thus calculated are significantly larger than the estimates presented in ICRP Report 26 and are consistent with estimates recently made in the ongoing reactor safety study of NUREG. The increase in lifetime risks is mainly due to the introduction of a new time projection model which appears to be more consistent with the epidemiological data for many late effect end points than the constant absolute risk model previously employed. Results from a study in which epidemiological data were stochastically simulated with a computer indicate that the shapes of actual dose effect curves might be significantly more influenced by pure chance than by the dose dependency of underlying ...

1988-04-01

499

Alpha-particle autoradiography in Cr-39. The determination of the microdistribution of activity and trace element analysis  

Energy Technology Data Exchange (ETDEWEB)

New and elaborate techniques for alpha-particle autoradiography of thick specimens based on the plastic nuclear track detector CR-39 have been developed. These permit a full analysis of both trace element and microdistribution of alpha-active nuclides present. The important features of the techniques are: 1) reliable low level configuration down to 10/sup -15/ Ci g/sup -1/, 2) high resolution alpha-particle spectroscopy in CR-39, 3) determination of the absolute abundance of alpha active nuclides present in the specimen, 4) determination of the distribution of emission with height up to 30 microns above the surface of the autoradiograph, 5) the local determination of the radon diffusion coefficient in the specimen which is needed to calculate the activity levels of /sup 222/Rn and daughter nuclei, 6) the analysis of small and large clusters of alpha-particle activity recorded on the autoradiograph. These techniques are briefly discussed.

1984-06-15