The development of a computational intelligent tools based on neural network to identify commercial losses or fraud (theft energy), considering information from a database electric utility, is presented.
A rare case of primary splenic cyst is shown in a young woman who had a left subcostal abdominal pain. Abdominal echography and CT scan revealed a cyst of the anterior aspect of the spleen. A sorologic test for hidatic disease was negative. On the basis of a presumed diagnostic of nonparasitic cyst, the patient was referred to a laparoscopic decapsulation with excision of the cysts wall not covered by splenic tissue. The patient was discharged 24 hours later. Histological report revealed epidermoid cyst. The laparoscopic approach has being recently considered an effective and less invasive alternative in the treatment of splenic diseases. We demonstrated that it should be considered for the treatment of splenic cysts present in a superficial location, with the advantage of organ preservation. (author)
The principal mathematical tools frequently available for calculations in Nuclear Engineering, including coupled neutron-gamma radiations shielding problems, involve the full Transport Theory or the Monte Carlo techniques. The Multigroup Albedo Method applied to shieldings is characterized by following the radiations through distinct layers of materials, allowing the determination of the neutron and gamma fractions reflected from, transmitted through and absorbed in the irradiated media when a neutronic stream hits the first layer of material, independently of flux calculations. Then, the method is a complementary tool of great didactic value due to its clarity and simplicity in solving neutron and/or gamma shielding problems. The outstanding results achieved in previous works motivated the elaboration and the development of this study that is presented in this dissertation. The radiation balance resulting from the incidence of a neutronic stream into a shielding composed by ...
CT is the most accurate method to detect pulmonary emphysema in vivo. They compared prospectively two different methods for emphysema quantitation in 5 normal volunteers and 20 consecutive patients with chronic obstructive pulmonary disease (COPD). All subjects were submitted to function tests and HRCT; three scans were acquired at preselected levels during inspiration. The type and extent of pulmonary emphysema were defined by two independent observers under blind conditions. Disagreements were subsequently settled by consent. All subjects were also examined with expiratory spiral CT using a density mask program, at two different cut-off levels (-850,-900 HU). Visual score and expiratory spiral density mask values (-850 HU) were significantly correlated (r = 0.86), but the visual extent of emphysema was always higher than shown by expiratory spiral CT. The emphysema extent assessed with both CT methods correlated with the function result of expiratory airflow obstruction and gas ...