WorldWideScience
1

Incidence and prognostic significance of radiological abnormalities in soft tissue injuries to the cervical spine  

Energy Technology Data Exchange (ETDEWEB)

The radiographs and initial clinical findings of 73 patients who had sustained trauma to the cervical spine without bony injury in vehicle collisions were reviewed. The patients were also re-examined clinically two years after the injury. Forty eight (65.8%) had abnormal radiographs at presentation - prevertebral soft tissue swelling in 15 (20.6%), degenerative changes in 15 (20.6%), and an angular deformity between two adjacent vertebral bodies in 27 (37.0%). The exact mode of inury is not associated with any specific radiographic appearance except that ''roll overs'' and side collisions are more likely to cause angulation in the cervical spine. (orig./GDG).

1988-10-01

2

Terminal phalangeal accessory ossification center of the thumb: an additional radiographic finding in Larsen syndrome  

International Nuclear Information System (INIS)

Larsen syndrome is an autosomal-dominant disorder characterized by multiple joint dislocations, vertebral anomalies and dysmorphic facies. Both autosomal-dominant and autosomal-recessive forms of the disorder have been proposed. Individuals with autosomal-dominant Larsen syndrome have characteristic ''cylindrical-shape'' thumbs caused by broad, shortened phalanges. Autosomal-dominant Larsen syndrome results from heterozygosity for mutations in filamin B, a cytoskeletal protein involved in multicellular processes. We report here a patient with a duplicated or accessory distal thumb phalanx and multiple large joint dislocations who was shown to be heterozygous for a filamin B mutation predicting the amino acid substitution G1691S. This adds a new radiographic finding, duplicated or accessory distal phalanx, to the radiographic abnormalities seen in this rare dominant disorder. (orig.)

2006-09-01

3

Somatostatin receptor scintigraphy might be useful for detecting skeleton abnormalities in patients with multiple myeloma and plasmacytoma  

International Nuclear Information System (INIS)

Somatostatin receptor expression has been demonstrated on a number of plasma cell lines. Therefore, we questioned whether somatostatin receptor scintigraphy (SRS) can be used to demonstrate in vivo multiple myeloma (MM) activity. SRS was performed in newly diagnosed (n = 9) or relapsing (n = 18) MM patients or in patients with localized plasmacytoma (n = 2). The results were compared with radiographic findings. A positive SRS was demonstrated in 44% of the newly diagnosed patients, in 83% of the relapsed patients and in both patients with plasmacytoma. The SRS findings corresponded with radiographic abnormalities in 40% of the patients. However, in relapsed patients 60% demonstrated increased SRS uptake in areas without new radiographic abnormalities. The positive SRS corresponded with histologically proven disease activity and responded ...

2010-01-01

4

CT in the study of thoracic-pulmonary complications after liver transplantation  

International Nuclear Information System (INIS)

In this article is reviewed the role of Computed Tomography (CT) in thoracic complications following ortho topic liver transplantation (OLT). In a post-OLT population of 567 patients transplanted in the Italian institutions, 100 patients (17.6%) were examined with chest CT. It was reviewed data relative to the total number of examinations, clinical and/or radiographic indications, the CT technique-i.e., conventional (with (out) intravenous, i.v., contrast material) or high-resolution (HRCT). It also reviewed the radiologic patterns and their correlation with the other clinical, bronchoscopic and/or laboratory results. Of 152 chest CT examinations, 45 (29.6%) were performed because of clinical indications, 31 (20.4%) because of a radiographic abnormality, 64 (42.1%) because of clinical and radiographic abnormality, 64 (42.1%) because of clinical and radiographic ...

2000-12-01

5

Evaluation of selective alveolo-bronchography with Fuji computed radiography and x-ray CT  

International Nuclear Information System (INIS)

Selective alveolo-bronchography (SAB) has been routinely used to evaluate anatomical changes in the bronchiole and its distal air spaces. A narrowing of the bronchiole and abnormal pooling of contrast medium in the destroyed air space are the prime findings. Since the object of radiography is extremely thin, direct magnification radiography is mandatory to obtain radiologic details. However, the problem with this technique is that radiographic quality varies depending upon the size of the patient and the concentration of contrast medium to be introduced in the lung. This study had two goals. One was to improve the image quality of SAB by Fuji Computed Radiography (FCR). FCR provides radiographs with a good contrast and stable density throughout a wide range of exposure factors which occur in the use of SAB. The other goal was to separately evaluate morphological abnormalities in the ...

1986-01-01

6

The role of Computerized Tomography in osteoid-osteoma diagnosis  

International Nuclear Information System (INIS)

Alcaptonuria is a rare autosomal recessive metabolic disease, due to the lack of homogentisic acid oxidase. The following accumulation of homogentisic acid brings about a black discoloration of both the urine alcaptonuria) and connective tissue (ochronosis). The ochronotic alterations into joint cartilages cause degenerative arthropathy and osteopenia. The radiological features of three unrelated cases of alcaptonuria are reported. Radiographic abnormalities of ochconotic arthropathy are found in both the spine and the extraspinal joints. In the spine, the progressive calcification and ''vacuum'' phenomenon of disc spaces are the most characteristic findings. Disc space narrowing is associated with calcification and marginal sclerosis of vertebral bodies and is accentuated by osteopenia. Osteophytes are usually absent or of small size; neverthless progressive formation of marginal intervertebral bridges and obliteration of ...

1988-01-01

7

Soft tissue signal abnormality associated with eosinophilic granuloma. Correlation of MR imaging with pathologic findings  

Energy Technology Data Exchange (ETDEWEB)

Six patients with eosinophilic granuloma were studied retrospectively in order to correlate the MRI appearances with the pathology. Ages ranged from 2 years 6 months to 11 years. The bones involved were the humerus, ulna, radius, femur, clavicle and ilium. Plain films, MRI and pathology specimens were obtained. A lytic lesion with indistinct margins, endosteal erosions and periosteal reaction was seen in all cases on plain radiographs. Bone marrow signal was decreased on T1-weighted images and increased on T2-weighted images throughout the bony lesion in all cases. T2-weighted images showed extensive soft-tissue abnormalities suggesting inflammatory changes in four cases. In two cases abnormalities were limited. Extensive changes correlated histologically with an early phase lesion. Localized minor changes were associated with a mid-phase lesion. Inflammatory soft-tissue changes could be associated with eosinophilic ...

1994-09-01

8

Comparative adequacy of conventional radiography, ultrasonography and Computed Tomography in twenty-six consecutive patients with acute superior mesenteric ischemia  

International Nuclear Information System (INIS)

Ischemic bowel disease is a rare disorder whose incidence is increasing as the mean age of the population increases. Diagnosis by clinical, laboratory and radiologic means is often difficult, and delay in definitive therapy results in substantial morbidity and mortality. A series of 26 consecutive patients, with proved acute superior mesenteric ischemia, was retrospectively reviewed: the authors reports the diagnostic methods performed preoperatively, the site and the cause of infarction and the time passed between the first radiograph and surgery. Plain abdominal radiographs were performed in 25 of 26 patients, screening abdominal US in 23 cases and CT in 19 cases. All radiological examinations were retrospectively reviewed by the three authors, independently, to recognize the different signs of infarction. On plain abdominal films, the findings warranting a presumptive diagnosis of bowel infarction were air-fluid levels ...

1997-01-01

9

Clinical evaluation of life size image of Fuji computed radiography for detection of diffuse interstitial lung diseases  

Energy Technology Data Exchange (ETDEWEB)

To evaluate the diagnostic accuracy of Fuji computed radiography (FCR) in the detection of interstitial pulmonary infiltrates, FCR life-size images at a pixel size of 0.1 mm were compared with conventional radiographs taken on the same day. Seventeen radiologists assessed the radiographs and FCR images of 56 cases, including 39 cases of various interstitial lung diseases such as interstitial pneumonia, pulmonary abnormalities associated with collagen disease, sarcoidosis, multiple pulmonary metastases, diffuse panbronchiolitis and pulmonary emphysema, and 17 normal controls. All of the pulmonary abnormalities were confirmed by high resolution CT. Observer performance tests were carried out using receiver operating characteristic analysis. In 21 cases of increased pulmonary density revealed by high resolution CT, FCR was significantly superior to conventional radiographs in the ...

1991-11-01

10

Clinical evaluation of life size image of Fuji computed radiography for detection of diffuse interstitial lung diseases  

International Nuclear Information System (INIS)

To evaluate the diagnostic accuracy of Fuji computed radiography (FCR) in the detection of interstitial pulmonary infiltrates, FCR life-size images at a pixel size of 0.1 mm were compared with conventional radiographs taken on the same day. Seventeen radiologists assessed the radiographs and FCR images of 56 cases, including 39 cases of various interstitial lung diseases such as interstitial pneumonia, pulmonary abnormalities associated with collagen disease, sarcoidosis, multiple pulmonary metastases, diffuse panbronchiolitis and pulmonary emphysema, and 17 normal controls. All of the pulmonary abnormalities were confirmed by high resolution CT. Observer performance tests were carried out using receiver operating characteristic analysis. In 21 cases of increased pulmonary density revealed by high resolution CT, FCR was significantly superior to conventional radiographs in the ...

1991-01-01

11

Distinguishing benign notochordal cell tumors from vertebral chordoma  

Energy Technology Data Exchange (ETDEWEB)

The objective was to characterize imaging findings of benign notochordal cell tumors (BNCTs). Clinical and imaging data for 9 benign notochordal cell tumors in 7 patients were reviewed retrospectively. Conventional radiographs (n = 9), bone scintigrams (n = 2), computed tomographic images (n = 7), and magnetic resonance images (n = 8) were reviewed. Eight of the 9 lesions were stained with hematoxylin-eosin and microscopically examined. There were 3 male and 4 female patients with an age range of 22 to 55 years (average age, 44 years). Two patients had two lesions at different sites. The lesions involved the cervical spine in 4 patients, the lumbar spine in 2, the sacrum in 2, and the coccyx in 1. The most common symptom was mild pain. The lesions of 2 patients were found incidentally during imaging studies for unrelated conditions. Five patients underwent surgical procedures. One patient died of surgical complications. All other patients have ...

2008-04-15

12

Computer-aided diagnosis of bone tumours and tumour-like skeletal abnormalities in childhood  

Energy Technology Data Exchange (ETDEWEB)

The method, use and results of computer-aided diagnosis of bone tumours and tumour-like skeletal abnormalities in childhood are described. One hundred and twentyone histologically verified cases were analysed and subjected to computer-aided diagnosis. Statistical methods were used, resulting in an accuracy of 96.7% and 91.7% respectively. In order to obtain additional confirmation of the diagnosis, a so-called growth rate was calculated by the computer. This proved to be a reliable criterion for evaluating the biological behaviour of tumours, irrespective of the histological diagnosis. The reasons for misdiagnosis were discussed. Attention is drawn to the importance of an accurate analysis of the radiographs and its input into the computer.

1982-06-01

13

Corrected transposition of the great arteries  

International Nuclear Information System (INIS)

The corrected transposition of the great arteries is an usual congenital cardiac malformation, which consists of transposition of great arteries and ventricular inversion, and which is caused by abnormal development of conotruncus and ventricular looping. High frequency of associated cardiac malformations makes it difficult to get accurate morphologic diagnosis. A total of 18 cases of corrected transposition of the great arteries is presented, in which cardiac catheterization and angiocardiography were done at the Department of Radiology, Seoul National University Hospital between September 1976 and June 1981. The clinical, radiographic, and operative findings with the emphasis on the angiocardiographic findings were analyzed. The results are as follows: 1. Among 18 cases, 13 cases have normal cardiac position, 2 cases have dextrocardia with situs solitus, 2 cases have dextrocardia with situs inversus ...

1981-12-01

14

Computed Tomography diagnosis of skeletal involvement in multiple myeloma  

International Nuclear Information System (INIS)

The authors assess the role of Computed Topography in the diagnosis and management of multiple myeloma (MM) and investigate if Computed Tomography findings can influence the clinical approach, prognosis and treatment. 273 multiple myeloma patients submitted to Computed Tomography June 1994, to December, 1996. The patients were 143 men and 130 women (mean age: 65 years): 143 were stage I, 38 stage II and 92 stage III according to Durie and Salomon's clinical classification. All patients were submitted to blood tests, spinal radiography and Computed Tomography, the latter with serial 5-mm scans on several vertebral bodies. Computed Tomography despicted vertebral arch and process involvement in 3 cases with the vertebral pedicle sign. Moreover, Computed Tomography proved superior to radiography in showing the spread of myelomatous masses into the soft tissues in a case with solitary permeative lesion in the left public bone, which facilitated subsequent biopsy. As for ...

1994-06-01

15

CT in the study of thoracic-pulmonary complications after liver transplantation; La Tomografia Computerizzata nello studio delle complicanze toraco-polmonari dopo trapianto del fegato  

Energy Technology Data Exchange (ETDEWEB)

In this article is reviewed the role of Computed Tomography (CT) in thoracic complications following ortho topic liver transplantation (OLT). In a post-OLT population of 567 patients transplanted in the Italian institutions, 100 patients (17.6%) were examined with chest CT. It was reviewed data relative to the total number of examinations, clinical and/or radiographic indications, the CT technique-i.e., conventional (with (out) intravenous, i.v., contrast material) or high-resolution (HRCT). It also reviewed the radiologic patterns and their correlation with the other clinical, bronchoscopic and/or laboratory results. Of 152 chest CT examinations, 45 (29.6%) were performed because of clinical indications, 31 (20.4%) because of a radiographic abnormality, 64 (42.1%) because of clinical and radiographic abnormality, 64 (42.1%) because of clinical and radiographic ...

2000-12-01

16

Opportunistic esophagitis in AIDS: Radiographic diagnosis  

International Nuclear Information System (INIS)

Between 1983 and 1986, 35 of 90 patients with acquired immunodeficiency syndrome (AIDS) had double-contrast esophagograms to rule out opportunistic esophagitis. The radiographs were reviewed without knowledge of the clinical or endoscopic findings. Candida esophagitis was diagnosed radiographically in 17 patients who had varying degrees of plaque formation and viral esophagitis in three who had discrete ulcers without plaques. All three patients with viral esophagitis (herpes in 2 and cytomegalo virus in one) and 15 of 17 with Candida esophagitis had endoscopic and/or clinical corroboration of the radiographic diagnosis. Thus, the authors' experience suggests that fungal and viral esophagitis can often be differentiated on double-contrast esophagography, so that appropriate antifungal or antiviral therapy can be instituted without need for endoscopic intervention.

17

Normal and abnormal fetal brain development during the third trimester as demonstrated by neurosonography  

International Nuclear Information System (INIS)

The multiplanar neurosonographic examination of the fetus enables superb visualization of brain anatomy during pregnancy. The examination may be performed using a transvaginal or a transfundal approach and it is indicated in patients at high risk for CNS anomalies or in those with a suspicious finding during a routine examination. The purpose of this paper is to present a description of the normal brain and of abnormal findings usually diagnosed late in pregnancy, including malformations of cortical development, infratentorial anomalies, and prenatal insults.

2006-02-01

18

Computed tomography in migratory disorders of human brain development  

International Nuclear Information System (INIS)

Computed tomographic findings in developmental brain anomalies are more easily classified when the system used is based on embryogenesis related to morphology. Analysis of computed tomographic findings in a series of 154 patients with brain anomalies (Chiari malformation not included) revealed that specific examples of abnormalities occurring in major stages of brain development may be recognized by computed tomography. This paper deals with a group of patients with abnormalities that reflect a disturbance in neuronal migration. (orig.).

19

Bladder outlet obstruction in a 6-month-old alpaca secondary to pelvic displacement of the urinary bladder  

UK PubMed Central (United Kingdom)

AbstractA 6-month-old female alpaca was presented for stranguria. Based on the history, physical examination findings, and radiographic studies, the alpaca was diagnosed with bladder...Full Text Available

2005-03-01

20

Computed tomography of the acetabular fractures  

Energy Technology Data Exchange (ETDEWEB)

In a retrospective study of 21 patients, in whom the acetabular fractures were suspected on initial radiographs, we compared and analysed the computed tomographic findings and plain radiographic findings. The results were as follow: 1. In patients with multiple trauma, no further change in position was required during CT examinations. 2. CT showed intraarticular loose bodies, which were invisible on plain radiographs. 3. CT was useful in detecting the fractures of acetabular rims, medial wall of acetabulum, and femoral head. 4. CT permitted better evaluation of shape, extent, and degree of separation of fracture fragments. 5. CT was helpful in detecting the associated fractures and soft tissue injuries. 6. CT also demonstrated the adequacy of reduction, the position of metallic fixation devices, and the presence or absence of remaining intraarticular osseous fragments after surgery.

1986-04-15

21

Destructive spondyloarthropathy in hemodialysis patients. Report of four cases and prospective study  

Energy Technology Data Exchange (ETDEWEB)

A destructive spondyloarthropathy is reported in four patients undergoing maintenance hemodialysis for chronic renal disease. In a separate investigation a controlled, prospective radiographic study of the cervical spine revealed this spondyloarthropathy in 4 (15%) of 26 long-term dialysis patients. A single disk level was involved in three patients, and two disc levels were involved in one patient. This spondyloarthropathy correlated with the duration of dialysis but not with the radiographic evidence of renal osteodystrophy or severity of laboratory abnormalities associated with hyperparathyroidism. Three of these four patients also had discovertebral erosions or destruction involving the lumbar spine. Cervical spine flexion views revealed evidence of ligamentous laxity or instability in three (12%) dialysis patients, all with vertebral resorption and disc space narrowing. It is postulated that this instability may ...

1988-04-01

22

Digital radiography of pulmonary abnormalities using Fuji computed radiography (FCR)  

Energy Technology Data Exchange (ETDEWEB)

Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best practical conditions were determined. (author).

1991-12-01

23

Digital radiography of pulmonary abnormalities using Fuji computed radiography (FCR)  

International Nuclear Information System (INIS)

Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best practical conditions were determined. (author).

1991-01-01

24

MRI of the foetal brain  

International Nuclear Information System (INIS)

Ultrasound examinations for foetal brain abnormalities have been a part of the routine antenatal screening programme in the UK for many years. In utero brain magnetic resonance imaging (MRI) is now being used increasingly successfully to clarify abnormal ultrasound findings, often resulting in a change of diagnosis or treatment plan. Interpretation requires an understanding of foetal brain development, malformations and acquired diseases. In this paper we will outline the technique of foetal MRI, relevant aspects of brain development and provide illustrated examples of foetal brain pathology.

2007-04-01

25

Plain radiographic predictors of survival in treated Ewing's sarcoma  

International Nuclear Information System (INIS)

We analyzed 16 radiographic features of primary Ewing's sarcoma in 342 patients from the IESS 7299 (Intergroup Ewing's Sarcoma Study) for prognostic significance. Of these, 3 features demonstrated a statistically significant relationship to survival: maximal tumor dimension, tumor location, and an appearance of honeycombing within the lesion. Those individuals with primary lesions centered in the pelvis, femur, or humerus had a worse survival rate than those with lesions centered elsewhere. Similarly, we observed an inverse relationship between the greatest dimension of the osseous portion of the lesion and survival. The radiographic finding of honeycombing also showed a statistical association with improved survival. However, this feature was observed infrequently, and its significance should be assessed further. Otherwise, no other feature that we analyzed showed any relationship to patient prognosis. (orig.).

26

Dextranomer/hyaluronic acid copolymer (Deflux) implants mimicking distal ureteral calculi on CT  

Energy Technology Data Exchange (ETDEWEB)

Periureteral or subtrigonal injection of dextranomer/hyaluronic acid (Dx/HA) copolymer (Deflux, Q-Med, Uppsala, Sweden) is an increasingly common endoscopic treatment for vesicoureteral reflux. We report a confusing radiographic finding of bilateral calcified Dx/HA injections initially thought to represent bilateral distal ureteral stones in a boy who presented with intermittent periumbilical pain. Urologists, radiologists, and emergency room physicians should be aware of the potential for calcification of ureteral implants of Dx/HA, and of the potentially confusing radiographic images that may result. (orig.)

2008-01-15

27

Imaging of membranous dysmenorrhea  

Energy Technology Data Exchange (ETDEWEB)

Membranous dysmenorrhea is an unusual clinical entity. It is characterized by the expulsion of huge fragments of endometrium during the menses, favored by hormonal abnormality or drug intake. This report describes a case with clinical, US, and MRI findings before the expulsion. Differential diagnoses are discussed. (orig.)

2001-06-01

28

CT findings of foreign bodies in the chest: a pictorial essay  

Energy Technology Data Exchange (ETDEWEB)

The most common causes of tracheobronchial foreign bodies are peanuts in children, and meat and dentures in adults. The most common causes of esophageal foreign bodies are coins in children and meat in adults. It is passable to diagnose a foreign body by visualization on a chest radiograph, if the foreign bodies are radio opaque. However, if the foreign bodies are radiolucent and the patients do not remember the history of aspiration, it is important to evaluate CT findings for foreign bodies and their complications. We describe the CT findings of various thoracic foreign bodies in children and adults.

2008-05-15

29

Cystic lesions of the seminal vesicles. Demonstration by MRI. Zystische Raumforderungen der Samenblasen. Darstellung mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

Between October 1990 and March 1991, 8 patients with cystic lesions in the region of the posterior bladder wall, the seminal vesicles and the prostate were examined by MRI. In all cases there was accurate characterisation of the lesion and of its anatomy. In 3 patients with abnormalities in the retrovesical space there was very good agreement with the operative findings. 4 patients were treated conservatively. In these patients there was good agreement with the findings on cystoscopy, CT and sonography. (orig.).

1992-07-01

30

Radionuclide liver and bone scanning in the evaluation of patients with endometrial carcinoma  

International Nuclear Information System (INIS)

Staging bone scans or skeletal surveys were obtained of 97 patients with endometrial carcinoma. Of the 77 patients with Stage I or II disease, no metastases were identified at staging. Three patients in the entire series demonstrated bony metastases; all of these metastases were detectable by radionuclide bone scan and radiographic bone survey. Eighty-nine patients were examined with radionuclide liver/spleen scanning at the time of staging. Four of the 89 initial scans were interpreted as demonstrating hepatocellular disease, and all four patients had abnormal liver function studies. Only one patient demonstrated a possible hepatic metastasis at initial diagnosis. This patient also had abnormal liver function studies. Based on these results, bone surveys and radionuclide bone scans are not indicated as screening procedures in endometrial carcinoma. It is suggested that screening for liver metastases in patients with ...

31

Clinical and ultrasonographic findings, diagnosis and treatment of pyelonephritis in 17 cows  

British Library Electronic Table of Contents (United Kingdom)

The goal of the present study was to describe the clinical, haematological and ultrasonographic findings and treatment of 17 cattle with pyelonephritis. Fifteen cattle had an abnormal general condition, which varied in severity; five animals had signs of colic. The urine was brownish-red in 11 animals and cloudy in 13. Clumps of purulent material were seen in the urine of nine animals and clots of blood in two. The specific gravity was lower than normal in 13 animals and ranged from 1.005 to 1.020. A urine test strip revealed protein in 16 animals, blood in 16 and leukocytes in 12. Bacteriological examination of urine yielded Corynebacterium renale in 11 animals, Arcanobacter pyogenes in two and Escherichia coli in one. Rectal examination revealed abnormalities of the urinary tract in 11 a...

2008-01-01

32

Radionuclide scintimetry for diagnosis of complications following femoral neck fracture  

Energy Technology Data Exchange (ETDEWEB)

A scintimetric study using Tc-99m MDP was made of 54 patients with delayed union, nonunion, or late segmental collapse of the femoral head, 4-92 months after femoral neck fracture. In radiographically verified collapse, the radionuclide uptake ratio between the femoral head on the fractured and on the intact side (HHR) was significantly higher than in fractures resulting in delayed union or nonunion. On the basis of scintimetric and radiographic findings, the patients with healing disturbances could be divided into three groups, characterized by the following features: (1) Satisfactory post-reduction position of the fracture without subsequent redisplacement and a high HHR, which as a rule turned out to be delayed union; (2) The same radiographic pattern but with a lower HHR, which in most cases resulted in nonunion; (3) Inadequate reduction or early redisplacement of the fracture with a high HHR, which ...

1984-01-01

33

Femoral neck buttressing: a radiographic and histologic analysis  

International Nuclear Information System (INIS)

Objective. To examine the incidence, radiographic and histologic findings of medial femoral neck buttressing in a consecutive group of patients undergoing total hip arthroplasty.Design. Biomechanical parameters were evaluated on standard anteroposterior pelvic radiographs of 113 patients prior to hip replacement surgery. Demographic information on all patients was reviewed and histologic evaluation was performed on specimens obtained at the time of surgery.Results. The incidence of medial femoral neck buttressing was found to be 50% in a consecutive series of patients undergoing total hip arthroplasty. The incidence was slightly higher in women (56% vs 41%). Patients with buttressing had increased neck-shaft angles and smaller femoral neck diameters than were seen in patients without buttressing. Histologic evaluation demonstrated that the buttress resulted from deposition bone by the periosteum on the femoral neck in the ...

2000-10-01

34

Computed tomography and magnetic resonance imaging of acquired abnormalities of the inner ear and cerebello-pontine angle  

International Nuclear Information System (INIS)

CT and MRI of acquired abnormalities of the inner ear and cerebello-pontine angle present themselves with very typical findings. The imaging should be adapted to the pathology looked for and either CT or MRI should be used alone or in combination.CT, especially high resolution CT (HRCT), provides an excellent bone contrast, while MRI has a much superior soft tissue contrast. Acute inflammatory changes of the inner ear are solely depicted by contrast-enhanced MRI. HRCT excellently depicts osseous changes of the inner ear and cerebellopontine angle such as chronic ossifying labyrinthitis occurring after acute labyrinthitis, otosclerotic or traumatic changes. Tumorous changes not yielding to bony changes are best delineated by MRI. Posttraumatic hemorrhage and chronic fibrotic changes within the labyrinth are depicted by MRI, only. In conclusion HRCT and MRI are excellent methods to delineate acquired abnormalities of the ...

2003-03-01

35

CF findings of bowel infarction in 56 surgical patients, 5 of whom with reversible ischemia  

International Nuclear Information System (INIS)

Bowel infarction is a rare and typical condition of the elderly; despite improvements in diagnostic imaging and vascular surgery, bowel infarction remains a major cause of acute abdomen, with mortality rates ranging 70-80%. Diagnosis on often late because clinical sings, laboratory data and radiologic findings are a specific. The authors investigated radiographic and particular CT patterns of intestinal infraction in 56 patients submitted to surgery within 12 hours of admission. We also report the CT findings of 5 of these patients who had reversible mesenteric ischemia. CT is more sensitive than radiography and does not exhibit the limitations of angiography (i.e., invasiveness, radiation exposure an complex organization. Therefore CT can presently be considered the method of choice in patients with suspected bowel infarction.

1999-04-01

36

Pulmonary nodule detection of chest phantom with CRT images; Comparison with conventional radiography (film-screen system) and FCR hardcopy  

Energy Technology Data Exchange (ETDEWEB)

Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided into four parts and displayed four images as a subsidiary diagnosis. The upper two ...

1989-08-01

37

Pulmonary nodule detection of chest phantom with CRT images  

International Nuclear Information System (INIS)

Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided into four parts and displayed four images as a subsidiary diagnosis. The upper two ...

1989-01-01

38

A lethal form of Gorham disease associated with extensive musculoskeletal pneumatosis: case report and review of the literature  

Energy Technology Data Exchange (ETDEWEB)

We report here the imaging findings of a rare case of a lethal form of Gorham disease in a young female patient. Multimodality imaging findings over 13 year-follow-up demonstrated progressive wide spread skeletal and soft tissue abnormalities with permeative osteolysis, pathological fractures and severe skeletal deformities. Unusual extensive osseous and soft tissue pneumatosis was illustrated on cross-sectional studies. The progressive nature of this form of Gorham disease and the subsequent complications eventually culminated in patient's death. (orig.)

2008-11-15

39

A lethal form of Gorham disease associated with extensive musculoskeletal pneumatosis: case report and review of the literature  

International Nuclear Information System (INIS)

We report here the imaging findings of a rare case of a lethal form of Gorham disease in a young female patient. Multimodality imaging findings over 13 year-follow-up demonstrated progressive wide spread skeletal and soft tissue abnormalities with permeative osteolysis, pathological fractures and severe skeletal deformities. Unusual extensive osseous and soft tissue pneumatosis was illustrated on cross-sectional studies. The progressive nature of this form of Gorham disease and the subsequent complications eventually culminated in patient's death. (orig.)

2008-11-01

40

Computed tomography in spinal osteoblastoma  

International Nuclear Information System (INIS)

In order to stress the role of computed tomography (CT) in the evaluation of benign spinal osteoblastoma, the authors examined by CT 10 patients with surgically and histologically proved osteoblastomas of the spine. Basing on surgical and histopathological findings CT proved to be a very important method for attesting the presence of the tumors (usually showed by radiographic examination), and specially for their staging and follow-up. CT in fact showed the real extent of the tumor into the spinal canal and towards the paraspinal soft tissues, and allowed the aerly detection of post surgical relapses. The authors conclude that CT is a primary diagnostic modality for preoperative planning and follow-up of benign osteoblastoma.

1986-01-01

41

Incidence of Central Vein Stenosis and Occlusion Following Upper Extremity PICC and Port Placement  

Science.gov (United States)

The purpose of this study was to determine the incidence of central vein stenosis and occlusion following upper extremity placement of peripherally inserted central venous catheters(PICCs) and venous ports. One hundred fifty-four patients who underwent venography of the ipsilateral central veins prior to initial and subsequent venous access device insertion were retrospectively identified. All follow-up venograms were interpreted at the time of catheter placement by one interventional radiologist over a 5-year period and compared to the findings on initial venography. For patients with central vein abnormalities, hospital and home infusion service records and radiology reports were reviewed to determine catheter dwelltime and potential alternative etiologies of central vein stenosis or occlusion. The effect of catheter caliber and dwell time on development of central vein abnormalities was evaluated. Venography performed ...

2003-04-15

42

Enhanced CT in the diagnosis of acute appendicitis to evaluate the severity of disease. Comparison of CT findings and histological diagnosis  

Energy Technology Data Exchange (ETDEWEB)

To assess the potential of CT in evaluating the histological severity of acute appendicitis in comparison with surgical and pathological findings. The CT images of 75 patients with surgically proven appendicitis, including 10 cases of catarrhal, 34 of phlegmonous, and 31 of gangrenous appendicitis, were retrospectively analyzed for the following five CT findings: hazy periappendiceal densities, enlarged appendix, increased enhancement of the appendiceal wall, increased enhancement of the periappendiceal intestinal wall, and deficiency of the appendiceal wall. By comparing all the CT findings and the pathological severity of appendicitis (catarrhal, phlegmonous, and gangrenous), the prevalence of the five CT findings was calculated for each pathological category. Abnormal CT findings were noted in only one case of catarrhal appendicitis. Increased enhancement of ...

2001-08-01

43

Focal lesions in external auditory canal: computed tomography images  

International Nuclear Information System (INIS)

To analyze and review the most common focal lesions of the external auditory canal (EAC), describing the computed tomography (CT) findings. The CT images of EAC were reviewed in a series of 167 patients. Abnormal findings were recorded in 13 cases. The CT images were correlated with otoscopic and/or intraoperative findings. There were four cases of osteoma (one located outside the EAC); all of which were treated surgically, as was the one case of exostosis. Six patients presented debris in EAC, coinciding with clinical evidence of external otitis. There were two cholesteatomas derived from EAC, one of them secondary to survery to treat osteoma. On patient was diagnosed as having a basal cell carcinoma of the ear, extending to EAC, but refused to undergo surgery. Five patients presented small triangular laminae of dense bone arising from the upper wall of the EAC which were defined as ...

44

The chance finding of an aneurysm of the right sinus of Valsalva in an 11-year-old child with a ventricular septal defect and a pericardial effusion  

British Library Electronic Table of Contents (United Kingdom)

Ventricular septal defects can occur as part of other congenital cardiac malformations or as an isolated finding. Aneurysms of the sinus of Valsalva are rare, most commonly involving the right or noncoronary sinuses. They can be congenital or acquired through infection, trauma, or degenerative diseases. They frequently co-exist with ventricular septal defects, aortic valve dysfunction, or other cardiac abnormalities. More commonly, sinus of Valsalva aneurysms are diagnosed after the clinical sequelae of rupture. Several etiologic factors may lead to the development of pathologic pericardial effusion and the detection of pericardial effusion was one of the first applications of echocardiography to gain widespread acceptance. We present a case of a chance finding of an aneurysm of the right ...

2011-01-01

45

Computerized tomography and head growth curve infantile macrocephaly with normal psychomotor development  

Energy Technology Data Exchange (ETDEWEB)

Macrocephaly was defined as a head measuring larger than 98th percentile. We have evaluated CT findings and head growth curves in 25 infants with large heads. Ten (40%) of 25 infants with large heads were normal developmentally and neurologically. Five (20%) of those were mentally retarded. The other 10 infants (40%) included hydrocephalus (4 cases), malformation syndrome (3 cases), brain tumor (1 case), metabolic disorder (1 case) and degenerative disorder (1 case). Their head growth curves were typed as (I), (II) and (III): Type (I) (excessive head growth curve to 2 SDs above normal); Type (II) (head growth curve gradually approached to 2 SDs above normal); Type (III) (head growth curve parallel to 2 SDs above normal). Ten of macrocephaly with normal psychomotor development were studied clinically and radiologically in details. They were all male. CT pictures of those showed normal or various abnormal findings: ...

1982-01-01

46

Low field magnetic resonance imaging of femoral neck fractures  

International Nuclear Information System (INIS)

Fourteen patients with cervical hip fractures were treated with internal fixation using titanium screws. The femoral head vitality was evaluated with "9"9Tc"m-MDP scintigraphy and scintimetry within 2 weeks postoperatively and by serial low field magnetic resonance imaging (MR). Two patients with reduced radionuclide uptake (femoral head ratio =# 1.0), MR revealed a focal decrease of the signal intensity in the femoral head or neck at 2, 3 and 7 months after fracture, respectively. The radiographs in one of these patients were normal at 7 months after fracture. The second one showed signs of necrosis at 16 months and the last one developed delayed/non-union. With a non-ferromagnetic osteosynthesis the healing course after femoral neck fracture can be studied with low field MR equipment without disturbing artifacts. The time period between ischaemia and definite abnormalities on MR may embrace several months. (orig.).

47

MR imaging of the lateral collateral ligaments after ankle sprain; Aussenbandrupturen des Sprunggelenkes - Darstellung mit der MRT vor und nach funktioneller Therapie  

Energy Technology Data Exchange (ETDEWEB)

35 patients with ankle sprain were examined by MRI and stress radiographs. 13 were operated afterwards, 22 patients underwent a functional conservative therapy and were examined by MRI and stress radiographs and second time after three months. MRI reports were correct in 12 of 13 operated cases. After conservative therapy we did not find any disrupted ankle ligament. MRI showed intact ligaments thickened by scar. (orig./MG) [Deutsch] 35 Patienten mit klinischem Verdacht auf Aussenbandruptur wurden mit der MRT untersucht. 13 Patienten wurden operiert, 22 konzervativ therapiert. Letztere wurden nach drei Monaten erneut mit MRT und gehaltenen Aufnahmen untersucht. Die MRT-Befunde stimmten in 12 von 13 Faellen mit den operativ erhobenen Befunden ueberein. Nach dreimonatiger konzervativer Therapie waren alle 22 Sprunggelenke stabil. Die rupturierten Baender stellten sich verdickt und durchgaengig dar. (orig./MG)

1995-09-01

48

Ewing's sarcoma. Radiographic pattern of healing and bony complications in patients with long-term survival  

International Nuclear Information System (INIS)

The radiographic appearance of Ewing's sarcoma was studied retrospectively in 22 patients who survived 5 years or longer after diagnosis and treatment. Expected changes from treatment, including regression of the extraosseous soft tissue mass, periostitis, and reconstitution of the cortex, occurred in all patients. Local recurrence occurred in one patient 10 years after complete remission whereas secondary osteosarcoma occurred more than 5 years after complete remission in two other cases. Both recurrent and secondary tumors presented as new lytic foci at the site of the original primary lesion. Lytic changes from radiation (radiation osteitis) may develop more than 2 years after treatment and in this sample; such findings were widely distributed in the radiation port. The authors conclude that bone remodeling and postradiation changes occur slowly over 2 years after treatment, and that any localized lysis at the primary site is suspicious for ...

49

Computed tomography of the chest in the postoperative recurrences of bronchogenic carcinoma  

International Nuclear Information System (INIS)

The authors describe the different types of postoperative carcinoma recurrences, as seen on CT examinations of the chest, in 38 patients who underwent different surgical procedures for bronchogenic carcinoma (12 pneumonectomies, 22 lobectomies, 2 segmentectomies, and 2 atypical resections). The recurrences were classified as follows: 1) recurrence in the bronchial stump; 2) limph node enlargement; 3) recurrence in the thoracic wall; 4) recurrence in the residual lobe; 5) pleural effusion; 6) nodule in the contralateral lung. The CT findings, Correlated with those from plain chest radiographs and clinical simptoms, indicate a higher incidence of recurrences in the hilar region, either in the bronchial stump or as node after total and subtotal resection are separately analyzed. While after pneumonectomy plain chest radiographs fail to demonstrate the recurrence in most cases, so that CT is nearly always mandatory, after ...

1990-01-01

50

Scintiscanning with aerosols of "9"9Tc"m DTPA in the diagnostic strategy for pneumocystosis in aids patients  

International Nuclear Information System (INIS)

Pulmonary clearance of an aerosol of "9"9Tc"m DTPA was measured in 21 non-smoking AIDS and pneumocystosis patients. The results were compared with those of pulmonary scintiscanning with gallium. All the patients exhibited increased clearance, evidence of a considerable alteration in alveolar permeability. This increase was also observed in patients with normal chest X-rays and normal blood gases. The average clearance in these patients was 6 #+-# 2% min"-"1 as compared with a normal 1.1 #+-# 0.3% min"-"1. Conversely, only four out of eight patients with normal chest X-rays had abnormal gallium scans. Clearance returned to normal after recovery. Measurement of DTPA clearance appears to be a very sensitive indicator for the detection and follow-up of pneumocystosis. However, it is not very specific since it can be increased by tobacco poisoning, drug abuse and the presence of lymphocytic alveolitis. An examination with normal findings can ...

1988-08-15

51

Perfusion impairments in children with reactive attachment disorder (RAD) on "9"9"mTc-ECD brain SPECT: comparison with MR findings  

International Nuclear Information System (INIS)

This study aimed to reveal that severe disturbance of attachment relationship with primary care-giver can affect functional and anatomical brain development by measuring cerebral perfusion on "9"9"mTc-ECD brain SPECT and correlative MRI. We included 18 children aged 31 to 76 months who met the diagnostic criteria of RAD as defined in DSM-IV and ICD-10 and SSP and CARS. "9"9"mTc-ECD SPECT was performed using CERASPECT. MRI was performed in all patients. SPECT data were visually assessed. 15 of 18 children had abnormal perfusion on SPECT, revealing decreased perfusion of Lt.thalamus (7/15) and Rt.thalamus (3/15), and bilateral thalami (5/15). Perfusion of basal ganglia was decreased in 8 children. Decreased perfusion of Lt. parietal area was seen in 2. Whereas, all patients had normal MR findings. Perfusion abnormalities involving thalamus, BG in most children with RAD were found in this study. These results suggest that ...

2002-11-15

52

Incidental discovery of asplenia syndrome, with situs inversus and a normal heart by radionuclide biliary imaging. A case report  

International Nuclear Information System (INIS)

/sup 99m/Tc biliary imaging was performed on a 34-year-old woman who was being investigated for suspected cholelithiasis. A left-sided liver was detected. On subsequent radionuclide imaging, partial visceral situs inversus and asplenia were demonstrated. Extensive roentgenographic investigation, ECG, echocardiogram, and laparotomy confirmed the radionuclide findings. Asplenia syndrome may exist without cardiovascular abnormalities and thus be undiscovered. Radionuclide imaging is important in the diagnosis of this syndrome.

53

Abnormalities of dystrophin, the sarcoglycans, and laminin alpha2 in the muscular dystrophies.  

UK PubMed Central (United Kingdom)

Abnormalities of dystrophin, the sarcoglycans, and laminin alpha2 are responsible for a subset of the muscular dystrophies. In this study we aim to characterise the nature and frequency of abnormalities...Full Text Available

1998-05-01

54

Clinical and ultrasonographic findings, diagnosis and treatment of pyelonephritis in 17 cows.  

Science.gov (United States)

The goal of the present study was to describe the clinical, haematological and ultrasonographic findings and treatment of 17 cattle with pyelonephritis. Fifteen cattle had an abnormal general condition, which varied in severity; five animals had signs of colic. The urine was brownish-red in 11 animals and cloudy in 13. Clumps of purulent material were seen in the urine of nine animals and clots of blood in two. The specific gravity was lower than normal in 13 animals and ranged from 1.005 to 1.020. A urine test strip revealed protein in 16 animals, blood in 16 and leukocytes in 12. Bacteriological examination of urine yielded Corynebacterium renale in 11 animals, Arcanobacter pyogenes in two and Escherichia coli in one. Rectal examination revealed abnormalities of the urinary tract in 11 animals; there was dilatation of the left ureter and/or enlargement of the left kidney in eight cases, and dilatation of the right ureter ...

2007-03-23

55

MRI findings of the brain in high-voltage electrical burn patient: case report  

Energy Technology Data Exchange (ETDEWEB)

We report the delayed sequelae arising in a case of electrical injury, reviewing the literature on the subject and focusing on the MRI findings of the brain. A 23-year-old male suffered burns to the left parietal scalp, both feet, and the anterior chest wall. Neurological symptoms and MRI abnormalities appeared 14 days after the insult and continued for about three months. T1-weight MR images demonstrated homogeneous hypointensity, while T2-weighted images depicted hyperintense finger-like projections. Contrast-enhanced T1-weighted images demonstrated strong band-like enhancement, indicating meningeal hyperemia. Follow-up MR imaging showed that the lesion had disappeared, indicating that the cerebral edema and meaningeal hyperemia were reversible.

2003-05-01

56

Cranial MRI of neurologically impaired children suffering from neonatal hypoglycaemia  

International Nuclear Information System (INIS)

Background. Metabolic disturbances such as anoxia and hypoglycaemia are important in causing maldevelopment of the neonatal brain. While there have been some pathology studies of the effects of neonatal hypoglycaemia on brain development, reports of MRI findings in such infants have been rare. Objectives. To describe the MRI findings in neurologically handicapped children who had suffered from neonatal hypoglycaemia and to evaluate the relationship between the neurological impairment and neonatal hypoglycaemia. Materials and methods. We retrospectively evaluated the MRI findings in eight full-term infants with neonatal symptomatic hypoglycaemia who later exhibited neurological handicap. The age at which the MRI scans were obtained ranged from 9 months to 8 years 10 months (mean 4 years 1 month, median 4 years). Results. The most striking findings were prolonged T1 weighting and T2 weighting in the ...

1999-01-01

57

Staging of osteochondritis dissecans of the knee and ankle with MRI. Comparison with conventional radiography and arthroscopy  

International Nuclear Information System (INIS)

A prospective study was performed on 50 patients suffering from osteochondritis dissecans of the knee and ankle to define criteria for stability and fixation of osteochondral lesions. Morphological parameters in MRI (size, fragmentation, cartilage, interface) and conventional radiology (separation, fragmentation) were registered and compared with arthroscopical staging. MRI staging based on different types of interfaces was demonstrated on T_1- and T_2-weighted images. MRI could correctly predict a Grade 1 lesion in 50%, a Grade 2 lesion in 90%, a Grade 3 lesion on 0%, and a Grade 4 lesion in 79%. Stable lesions were differentiated from unstable lesions in 90%. Radiographic findings corresponded with arthroscopic staging in only 56% of the cases because fibrotic connection may guarantee stability in case of bony separation. (orig./MG).

58

Real time neutron radioscopy - trends and applications  

International Nuclear Information System (INIS)

Real Time Radiography (RTR) finds extensive applications for inspection of objects on assembly lines for rapid inspection. A typical RTR widely used includes a image intensifier, CCD camera, image processor and high resolution TV monitor in addition to radiographic source. Image intensifiers used in X-radiography employ CsI as the input detector. With the increased use of neutrons as radiation source, real time neutron radiography is also being practised widely. Image intensifiers used in neutron radiography employ gadolinium as the input screen. The neutron image intensifier system at the authors laboratory essentially consists of a 9 inch Trifield image intensifier tube, motorised zoom lens, CCD camera and a high resolution TV monitor

2003-11-12

59

Extrinsic allergic alveolitis induced by the yeast Debaryomyces hansenii.  

Science.gov (United States)

A 65-yr-old female developed cough, fever and dyspnoea following repeated exposure to a home ultrasonic humidifier. High-resolution computed tomography showed ground-glass opacity in both lung fields. Arterial blood gas analysis gave an oxygen tension of 8.38 kPa (63 Torr). Pulmonary function testing revealed restrictive ventilatory impairment with a reduction in the diffusing capacity. The diagnosis of extrinsic allergic alveolitis (EAA) was confirmed by radiographic findings, pathological evidence of alveolitis and reproductive development by a provocation test to the humidifier water. The yeast Debaryomyces Hansenii was the only microorganism cultured from the water of the humidifier. The double diffusion precipitating test and lymphocyte proliferative response was positive for an extract of D. Hansenii, providing evidence to incriminate this fungus. This is the first described case of EAA caused by D. Hansenii. PMID:12449192

2002-11-01

60

Acute femoral neck fracture  

International Nuclear Information System (INIS)

Ten patients with traumatic femoral neck fracture were studied with MR imaging (0.5 T, Magnetom, Siemens): unenhanced (multiecho, TR/TE = 1,600/30--240 [repetition time/echo time, msec]; gradient echo, TR/TE = 315/14, #theta# = 90 degrees) and Gd-DTPA enhanced (0.1 mM/kg body weight, Magnevist, Schering; gradient echo, TR/TE = 315/14, #theta# = 90 degrees). MR images were compared with clinical-radiographic findings. Digital subtraction angiography of the femoral head (FH) in five patients showed complete interruption of blood supply to the FH in three patients (signal intensity of FH did not increase on postcontrast images) and intact FH arteries in two patients (FH signal increased on postcontrast images, as did the healthy-side signal).

61

Abces du muscle iliopsoas : complication rare de la sacro-iliite a pyogene chez lenfant  

British Library Electronic Table of Contents (United Kingdom)

Pyogenic sacroiliitis is a rare entity in children. Diagnosis is often delayed because of its variable clinical presentation, low suspicion by the examining physician, and rare findings on radiographs. Delayed diagnosis, however, results in complications such as iliopsoas abscess. We report the case of a 12-year-old girl hospitalized with a 21-day history of fever, pain in the left iliac fossa, and flexion contracture of the hip. On examination, she had fever (38.9 ^oC), psoitis, localized tenderness at the left sacroiliac joint, and pain elicited by lateral compression of the pelvis. The abdominal examination was normal. The erythrocyte sedimentation rate was 130mm in the first hour, C-reactive protein was 186mg/l, and the white blood cell count was 18,400/mm^3, with 79% neutrophils. Urin...

2010-01-01

62

An availability of brain magnetic resonance imaging (MRI) in the early diagnosis of latent hepatic encephalopathy  

Energy Technology Data Exchange (ETDEWEB)

Brain MRI was carried out in patients with chronic liver diseases. No abnormal findings were recognized in patients with chronic viral hepatitis, while 59.2% of cirrhotics showed a symmetrically strong signal in basal ganglia on T1 weighted image in MRI. This finding significantly related with lowered Fischer`s ratio of serum amino acid, increased levels of serum phenylalanine, tyrosine and hyaluronic acid, prolonged prothrombin time and decreased platelet counts in the peripheral blood. Overt hepatic encephalopathy was observed in 6 of 34 patients with the strong signal in MRI during follow-up period, while none of patients without that finding developed hepatic encephalopathy. These results have indicated that the strong signal in basal ganglia on MRI appears in cirrhotic patients with severe liver dysfunction, and it is an useful index in the early diagnosis of latent hepatic encephalopathy. An ...

1996-03-01

63

Computed tomography whole body imaging in multi-trauma: 7 years experience  

International Nuclear Information System (INIS)

AIM: To assess the impact of the introduction of a computed tomography (CT) imaging protocol for multi-trauma patients on the workload, overall diagnostic yield, and effect on detection of cervical spine injury and pneumothorax. METHOD: Between February 1997 and April 2004, all patients presenting acutely to the Emergency Department (ED) with haemodynamically stable trauma (Abbreviated Injury Scale 3 or more) involving more than two body systems were imaged with a comprehensive pre-set helical CT protocol (including non-contrast head, cervical spine: cranio-cervical and cervico-thoracic junctions; and oral and intravenous contrast-enhanced thoracic, abdomen and pelvis) after initial triage and a standard trauma series of radiographs (chest, lateral C-spine and pelvis). Diagnosis of cervical spine fracture and pneumothorax was noted before and after the CT protocol was carried out and findings from all studies were recorded prospectively. ...

2006-04-01

64

Application of 18F-fluorodeoxyglucose positron emission tomography to detection of proximal lesions of obstructive colorectal cancer  

International Nuclear Information System (INIS)

In cases of obstructive colorectal cancer (CRC), preoperative diagnosis of the proximal lesion is often difficult when the primary lesion impedes the passage of the endoscope. The aim of this study was to evaluate the usefulness of fluorine-18-fluorodeoxyglucose positron emission tomography (FDG-PET) in such cases. A total of 52 obstructive CRC patients who underwent preoperative FDG-PET and subsequent surgical resection were retrospectively reviewed. The correlation between characteristics of the proximal lesion and FDG-PET findings was analyzed statistically. There was a significant correlation between the proximal lesion size and the maximum standardized uptake value (P=0.00016). Abnormal FDG accumulation in the proximal colon indicated the existence of proximal cancer or adenoma with a sensitivity of 50% and a specificity of 100%. There was a significant difference in the distribution of tumor size between the cases with proximal ...

2010-10-01

65

A study on brain CT of neurological endemic cretinism  

International Nuclear Information System (INIS)

A study on brain CT was made in 20 cases of typical endemic cretinism and 15 cases of normal persons. These patients from severely iodine deficient area were diagnosed as neurological endemic cretinism characterized by severe mental retardation with impairment of hearing, speech, neuromotor, etc. to varying degrees. The brain CT showed that there were many and deep depressions in cerebral cortex, especially in frontal and parietal lobes of some cretins, the lateral ventricle system was dilated, particularly in posterior part of it, and the interhemisphere fissure, lateral fissure and subarachnoid cisterns were also expanded. The CT value of cortex was higher and white matter was lower than that of normal persons. In some severe cases, the two hemispheres of brain were not the same in size. These findings above indicated that these endemic cretins had a severe retardation of brain development including cerebral cortex and white matter. In addition, some ...

66

A radiologic analysis and comparative evaluation of hysterosalpingographic and laparoscopic findings in infertile patients  

Energy Technology Data Exchange (ETDEWEB)

Hystreosalpingogram of 375 patients with infertility were reviewed with reference to radiological feature of each pathology and a comparative study of hysterosalpingography and laparoscopy in 36 patients was presented. This results were as follows;1. In 375 cases of infertility, 191 cases (50.9%) were primary infertility and 181 cases (49.1%) were secondary infertility. 2. The peak age distribution was 26 to 30 year old group in 211 cases (56.3%), and the peak duration of infertility was less than 3 years in 256 cases (68.3%). 3. Abnormal uterine findings were 115 cases (30.7%) and there were 73 cases of filling defects, 13 cases of irregularity, 12 cases of uterine flexion, 11 cases of congenital anomaly, and 9 cases of hypoplasia among them. 4. Abnormal tubal findings were 196 cases (52.3%) and there were 103 cases of simple obstruction, 69 cases of hydrosalpinx, and 50 cases of peritubal adhesion ...

1984-09-15

67

The Significance of PITX2 Overexpression in Human Colorectal Cancer  

British Library Electronic Table of Contents (United Kingdom)

Purpose The paired-like homeodomain transcription factor 2 (PITX2) gene encodes a transcription factor controlled by the WNT/Dvl/CTNNB1 and Hedgehog/TGFB pathways in the pathogenesis of colorectal cancer (CRC). Although PITX2 is reportedly involved in various functions, including tissue development by controlling cell growth, its significance in CRC remains unclear. We report our findings regarding abnormal PITX2 expression in human CRC. Methods PITX2 expression was evaluated in 5 human CRC cell lines and 92 primary CRC samples. Cell growth was evaluated after inhibition of PITX2 expression or after exogenous introduction of PITX2. Results PITX2 expression was seen in all the five CRC cell lines. The study of tissue samples indicated that PITX2 expression was significantly higher in cancer...

2011-01-01

68

Subdural effusions in children under two years. Clinical and computer-tomographical data  

Energy Technology Data Exchange (ETDEWEB)

We investigated 161 children under 24 months of age by CT of the skull and reviewed the anamnestic and clinical history. 87 children showed subdural effusions, and 74 did not. There were 33 patients with other pathological findings in CT, and 41 had normal scans. Age and sex distribution as well as localization of the subdural effusions were consistent with the literature. The 87 children with subdural effusions represented 17% in a sample of about 5000 CT scans. CT was the most reliable method for diagnosis of subdural effusions, compared to other techniques. There was a preponderance of small subdural effusions from 1 to 7 mm thickness (51%). Other CT abnormalities accompanying subdural effusions were found. Most frequently the interhemispheric sulcus was dilated and an internal hydrocephalus was present. Also in our group there were 7 anamnestical and 6 clinical symptoms highly diagnostic of subdural effusions.

1980-05-01

69

Physical findings in the upper airways related to obstructive sleep apnea in men and women  

British Library Electronic Table of Contents (United Kingdom)

Conclusions. There are gender differences when it comes to the risk factors for sleep apnea. Large tonsils, a high tongue and a wide uvula are risk factors for sleep apnea in men, while large tonsils and a retrognathic mandible are risk factors in women. Upper airway abnormalities including mandibular retrognathia are, however, unable to predict sleep apnea among snorers being investigated for suspected sleep apnea. Objectives. To identify gender-specific risk factors for obstructive sleep apnea and the diagnostic performance from physical upper airway examinations among snoring men and women investigated because of suspected sleep apnea. Patients and methods. The dimensions of the uvula, tonsils, velopharynx and tongue, and nasal septal deviation, mandibular position, neck circumference, ...

2007-01-01

70

Nursing Diagnosis of Activity Intolerance: Clinical Validation in Patients With Refractory Angina  

British Library Electronic Table of Contents (United Kingdom)

PURPOSE.- The study aims to clinically validate the defining characteristics (DCs) of the nursing diagnosis (ND) of Activity Intolerance for patients with ischemic heart disease and refractory angina. METHODS.- Cross-sectional study was used, involving 22 patients with ND of Activity Intolerance. The Fehring method was used to validate the ND. FINDINGS.- Most DCs presented reliability indexes between 0.5 and 0.79. Three DCs presented reliability indexes - 0.8. CONCLUSION.- All DCs were validated, and electrocardiographic changes indicating ischemia, verbal report of fatigue, and abnormal rate response to activity were considered as DC major. IMPLICATIONS FOR NURSING PRACTICE.- This study is relevant in daily nursing practice for guidance in establishing the care plan and describing the ass...

2011-01-01

71

Metallurgical Investigation of a Prematurely Failed Concentric Reducer Tube Used in a Hot-Rolling Mill  

British Library Electronic Table of Contents (United Kingdom)

A concentric reducer tube, which was a part of the top exit roughing hydraulic descaler in a hot strip mill failed prematurely under working pressure. A detailed metallurgical investigation comprising physical examination, optical microscopy, scanning electron microscopy, and electron probe microanalysis was carried out to find out the genesis of the failure. Physical examination revealed cracks located symmetrically around the circumference of the tube that ran along its full length, up to the weld beads at both ends. Optical microscopy of etched samples revealed a banded ferrite-pearlite structure and the existence of forging folds near the change-in-section(160? fillets). Cracks were found to initiate from these forging folds. No structural abnormalities were found in the weld beads and...

2007-01-01

72

Malicious Hubs: Detecting Abnormally Malicious Autonomous Systems  

Energy Technology Data Exchange (ETDEWEB)

While many attacks are distributed across botnets, investigators and network operators have recently targeted malicious networks through high profile autonomous system (AS) de-peerings and network shut-downs. In this paper, we explore whether some ASes indeed are safe havens for malicious activity. We look for ISPs and ASes that exhibit disproportionately high malicious behavior using 12 popular blacklists. We find that some ASes have over 80% of their routable IP address space blacklisted and others account for large fractions of blacklisted IPs. Overall, we conclude that examining malicious activity at the AS granularity can unearth networks with lax security or those that harbor cybercrime.

2010-03-01

73

Evaluation of the hepatobiliary function with "9"9"mTc-EHIDA imaging during total parenteral nutrition  

International Nuclear Information System (INIS)

14 surgical patients with non-hepatobiliary diseases were studied with "9"9"mTc-EHIDA imaging to evaluate the effect of total parenteral nutrition (TPN) on the hepatobiliary function. Duration of TPN ranged from 6-56 days, 10 of the 14 patients Beijing within 10 days. The results showed that: (1) 11 of 14 patients had abnormal scintigraphic features. The most prominet findings were delayed liver excretion and prolonged blood clearance time. This fact suggests that not only the rate of excretion of the bile from the liver is decreased but the uptake ability of the hepatorcyte is also impaired. (2) The effect of TPN on liver function is reversible. It was concluded that in order to prevent irreversible damage of hepatobiliary function caused by TPN, the duration of TPN should not be too long and oral intake of nutrients should be resumed as soon as possible.

74

Brain CT image and handedness of schizophrenia  

International Nuclear Information System (INIS)

Brain CT images were reviewed of 98 schizophrenic patients and 90 healthy persons in relation to handedness and aging. CT images were further reconstructed to examine morphologically subtle changes in each region. Schizophrenic patients had progressive brain atrophy and dilated lateral ventricles, especially on the left side and in the posterior part of the lateral ventricle. These findings were more marked in left-handed than in right-handed schizophrenic patients. According to age groups, there were significant differences between schizophrenic and normal persons over the age of 40. The incidence of left handedness was significantly higher in schizophrenic patients in their fourties than the age-matched normal persons (31.4% vs 15.1%). Morphological abnormality and laterality might be due to the same pathologic consequences. (N.K.).

75

Computed tomography in the diagnosis of cavum septum pellucidum  

Energy Technology Data Exchange (ETDEWEB)

The cavum septum pellucidum is an anatomical variants of the septum pellucidum, and lying between two lateral ventricles and this is referred to as the fifth ventricle. Occasionally, posterior extension of the cavum septum pellucidum towards the splenium is seen and this is known as the cavum vergae, or sixth ventricle. The septum is double membrane and occasionally a narrow cavity containing CSF is present between these membrane. The roof of the cavum septum pellucidum is formed by the corpus callosum and its floor by the anterior pillars of the fornix. This cavum outlined with air is occasionally seen in the pneumoencephalography. Brain CT scans of 1000 patients were performed, and the diagnosis could be made on the basis of the characteristic shape, density and location. Other diagnostic procedure are not necessary in these cases. Patients were examined with CT scanner from June-80' to Dec-80', at department of radiology, Maryknoll Hospital, and 13 cases were ...

1981-09-15

76

Le leucodistrofie: aspetti clinici e quadri con Tomografia Computerizzata e con Risonanza Magnetica  

International Nuclear Information System (INIS)

Leukodystrophies are inherited white matter diseases due to abnormalities occurring in myelin synthesis and/or maintenance. The most common types of these rare childhood conditions are represented by adrenoleukodystrophy, metachromatic leukodystrophy, Canavan's, Alexander's, Krabbe's, and Pelizaeus-Merzbacher's diseases. Most of them are lethal during childhood, with the exception of the adrenoleukodystrophy-adrenomyeloneuropathy complex, which sometimes, during its early phases, may be cured with a dietary therapy. The aims of this paper are: 1) the description of inheritance factors, pathogenesis, pathological and clinical findings of each of the most frequent childhood leukodystrophies; 2) the description of the most common patterns of these conditions on CT and MR imaging; 3) the evaluation of the diagnostic capabilities of these two imaging techniques and the comparison of their results. Finally, some of the therapies suggested for the ...

1991-01-01

77

Hyperoxia-induced acute lung injury using a pig model. Correlation between MR imaging and histologic results  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to correlate MR imaging findings with pathology in experimental hyperoxia-induced acute lung injury, which has similar pathology to diffuse alveolar damage (DAD). Seventeen Yorkshire pigs were studied. These animals were exposed to more than 80% oxygen for 24, 48, 72, and 96 hours in a sealed cage. The lungs were removed and inflated with air infused through the trachea, and then examined by both MRI and high-resolution CT (HRCT). T1-weighted spin-echo (T1WSE), T2-weighted fast (T2WFSE), and half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequences were performed. Severity in MR findings and signal-to-noise ratios (SNR) on MR images were well correlated with pathological scores. CT values were also correlated well with pathologic scores. Abnormal SNR values were obtained from a pathological score of 5, whereas abnormal CT values were obtained from a ...

2001-06-01

78

The application of the Fuji Computed Radiography system for the diagnosis of pneumoconiosis; Determination of optimum conditions of image processing  

Energy Technology Data Exchange (ETDEWEB)

A computer controlled digital system, Fuji Computed Radiography (FCR) is capable of providing more stable output image than conventional screen/film system. So FCR would be an ideal system for the detection of pneumoconiosis due to the constant high quality of the output films. We tried to find the optimum image processing to compensate the small size (1/2 in length of a full-size radiograph) of the output image of digital radiography. The best result for FCR was given with gamma 0.85 and 0.30 enhancement of response at spatial frequency of 0.085 cycle/mm. On the other hand, the digitally processed FCR size ILO standard films, the characteristics of which is different from FCR output films, proved to be most preferable when the image processing is made with gamma 0.85 and 0.25 enhancement at spacial frequency of 0.17 cycle/mm. If the above mentioned image processings are adopted, FCR can be used for the diagnosis of pneumoconiosis with the same ...

1993-06-01

79

The application of the Fuji Computed Radiography system for the diagnosis of pneumoconiosis  

International Nuclear Information System (INIS)

A computer controlled digital system, Fuji Computed Radiography (FCR) is capable of providing more stable output image than conventional screen/film system. So FCR would be an ideal system for the detection of pneumoconiosis due to the constant high quality of the output films. We tried to find the optimum image processing to compensate the small size (1/2 in length of a full-size radiograph) of the output image of digital radiography. The best result for FCR was given with gamma 0.85 and 0.30 enhancement of response at spatial frequency of 0.085 cycle/mm. On the other hand, the digitally processed FCR size ILO standard films, the characteristics of which is different from FCR output films, proved to be most preferable when the image processing is made with gamma 0.85 and 0.25 enhancement at spacial frequency of 0.17 cycle/mm. If the above mentioned image processings are adopted, FCR can be used for the diagnosis of pneumoconiosis with the same ...

1993-01-01

80

Soft tissue manifestations of early rheumatic disease. Imaging with MRI  

International Nuclear Information System (INIS)

The aim of this study was to evaluate typical magnetic resonance imaging (MRI) findings in early rheumatic diseases manifesting at the soft tissues of the hand using a retrospective analysis. A total of 186 MRI examinations of patients with clinical suspicion of a rheumatic disease were evaluated in a consensus reading by two experienced radiologists. All imaging patterns were assessed with respect to their type and localization. Under blinded and non-blinded conditions diagnoses were correlated with final clinical diagnosis. The most frequent diagnoses were rheumatoid arthritis (RA, 45.7%) and psoriatic arthritis (PsA, 15.6%). The mean correlation between clinical and MRI diagnosis (r) was 0.75 in blinded and 0.853 in non-blinded reading (p <0.001). The following extra-articular imaging patterns were found: synovitis (59.1%), tendovaginitis (91.4%), dactylitis (14.5%), and bone marrow edema (18.3%). Only dactylitis was specific for a particular rheumatic ...

2006-08-01

81

Diagnostic capabilities of quantitative bone scintigraphy in ankylosing spondylitis: A comparison with radiography  

International Nuclear Information System (INIS)

In 576 patients quantitative scintigraphy of the sacroiliac joints and the spinal cord with "9"9"mTc-pyrophosphate was performed. 328 were patients with proven ankylosing spondylitis according to the New York criteria. 120 were patients with a clinically and roentgenologically suspected ankylosing spondylitis and 128 persons formed a healthy control group. The count rate in small regions of interest (ROI) in the sacroiliac joints, the spinal cord and the os sacrum were compared on the basis of indexes. The scintigraphic data of patients with ankylosing spondylitis were compared with the healthy control group and with the radiographic findings and radiologic staging of the disease. In a longitudinal follow-up study during 1 to 6 years these investigations were continued together with clinical and roentgenological checks. Quantitative bone scintigraphy provides characteristic indexes for ankylosing spondylitis, indicating the increased mineral ...

82

'Hair-on-end' skull changes resembling thalassemia caused by marrow expansion in uncorrected complex cyanotic heart disease  

Energy Technology Data Exchange (ETDEWEB)

''Hair-on-end'' skull changes resembling thalassemia were rarely described in the 1950s and 1960s in children with cyanotic congenital heart diseases; these changes were described almost entirely in patients with tetralogy of Fallot or D-transposition of the great arteries. As these lesions have become correctable, the osseous changes, never common, seem now only to exist in a small number of patients with uncorrectable complex cyanotic congenital heart disease who survive in a chronic hypoxic state. We present two cases: a case of marked marrow expansion in the skull of a 5-year-old boy with uncorrectable cyanotic heart disease studied by CT, and a second case of an 8-year-old with tetralogy of Fallot and pulmonary atresia studied by plain skull radiographs. The true incidence of these findings is unknown. (orig.)

2005-07-01

84

Radiation dose in computerized tomography  

International Nuclear Information System (INIS)

Dosimetric studies in 80 patients examined with the tomographic device 'Somatom' are reported. The gonad doses are compared to those of conventional radiographic techniques.

85

Radiologic findings of extraosseous Ewing's sarcoma  

International Nuclear Information System (INIS)

The purpose of this study is to evaluate the radiologic findings of the extraosseous Ewing's sarcoma. Six patients with pathologically confirmed extraosseous Ewing's sarcoma were retrospectively reviewed. Patients included two men and four women with an average age of 21.5 years (age range 9-48 years). Plain radiographs (six patients), magnetic resonance (MR) images (five patients), computed tomographic (CT) scans (three patients) and whole body scintigraphy (two patients) were reviewed and analyzed. Images were evaluated with regard to lesion location, size, margin, muscle or bone involvement and intrinsic imaging characteristics on CT and MRI. The tumors were located in the thigh (three patients), back (two patients) and upper arm (one patient). The tumors ranged in size from 2.3 cm to 7.5 cm (mean, 5.2 cm), were mainly well circumscribed and showed no evidence of calcification prior to treatment. Margins were well defined in four out of the ...

2005-09-01

86

CF findings of bowel infarction in 56 surgical patients, 5 of whom with reversible ischemia; Aspetti alla tomografia computerizzata dell'infarto intestinale. 56 pazienti sottoposti a interventi chirurgico di cui 5 con ischemia mesenterica reversibile.  

Energy Technology Data Exchange (ETDEWEB)

Bowel infarction is a rare and typical condition of the elderly; despite improvements in diagnostic imaging and vascular surgery, bowel infarction remains a major cause of acute abdomen, with mortality rates ranging 70-80%. Diagnosis on often late because clinical signs, laboratory data and radiologic findings are a specific. The authors investigated radiographic and particular CT patterns of intestinal infraction in 56 patients submitted to surgery within 12 hours of admission. We also report the CT findings of 5 of these patients who had reversible mesenteric ischemia. CT is more sensitive than radiography and does not exhibit the limitations of angiography (i.e., invasiveness, radiation exposure and complex organization). Therefore CT can presently be considered the method of choice in patients with suspected bowel infarction. [Italian] L'infarto intestinale rappresenta una malattia rara e tipica del soggeto ...

1999-04-01

87

Clinical application of FCR for the portable chest radiographs in ICU  

Energy Technology Data Exchange (ETDEWEB)

The diagnostic value of the portable chest radiography obtained with Fuji computed radiography (FCR) was evaluated in comparison with conventional images in 23 patients who were admitted to ICU in Yokohama City University Hospital. On the whole , FCR produced more exellent images than conventional screen-film radiographs. Especially the evaluation for the demonstration of the catheters, the endotracheal tubes and the tracheal shadows obtained high score. We discuss the clinically utility of FCR for the portable chest radiographs in ICU. (author).

1989-08-01

88

Clinical application of FCR for the portable chest radiographs in ICU  

International Nuclear Information System (INIS)

The diagnostic value of the portable chest radiography obtained with Fuji computed radiography (FCR) was evaluated in comparison with conventional images in 23 patients who were admitted to ICU in Yokohama City University Hospital. On the whole , FCR produced more exellent images than conventional screen-film radiographs. Especially the evaluation for the demonstration of the catheters, the endotracheal tubes and the tracheal shadows obtained high score. We discuss the clinically utility of FCR for the portable chest radiographs in ICU. (author).

1989-01-01

90

Radiographic features of Ewing's sarcoma of the bones of the hands and feet  

International Nuclear Information System (INIS)

The radiographic features of Ewing's sarcoma of the bones of the hands and feet are reviewed utilizing cases obtained from the Mayo Clinic patient files and the consultation files of Drs. D.C. Dahlin and K.K. Unni. This series consists of a total of 43 cases of pathologically proven Ewing's sarcoma involving the small bones of the hands and feet. The classic radiographic features of Ewing's sarcoma in the long bones, including lytic, permeative destruction, aggressive periosteal reaction, cortical violation, and a soft tissue mass, are also seen in the bones of the hands and feet, with similar frequency. These classic features are most commonly present in lesions affecting the short tubular bones. Lesions affecting the tarsal bones more often demonstrate atypical radiographic features. These atypical radiographic appearances may play a role in the reported delay in diagnosis of Ewing's sarcoma within ...

2001-03-01

91

Clinically silent heterotaxy with polysplenia syndrome and IVC azygous continuation draining to SVC: CT findings. Case report  

International Nuclear Information System (INIS)

Patients with heterotaxy syndrome often have complex cardiac and extracardiac anomalies requiring further detailed diagnostic evaluation. They often present severe cardiac failure early in life. Newer radiological modalities in the form of spiral computed tomography (CT) and three-dimensional reconstruction of spiral CT allow clear definition of the anatomy of these anomalies. A 59-year-old woman was diagnosed with polysplenia and multiple anomalies in an abdominal ultrasonography (US) during a control medical examination due to a trivial dietary mistake. She was then referred to our institution for further examination of these anomalies and an additional thoraco-abdominal computed tomography (CT) examination. The patient was totally asymptomatic at the time of admission. There was no significant past history and no abnormal laboratory data. We performed abdominal, pelvic and thoracic CT examinations using Somatom Siemens Emotion scanner. Non-enhanced sections were ...

2007-01-01

92

Magnetic Resonance Perfusion Imaging in Malformations of Cortical Development  

International Nuclear Information System (INIS)

Background: Malformations of cortical development vary in neuronal maturity and level of functioning. Purpose: To characterize regional relative cerebral blood volume (rCBV) and difference in first moment transit time (TTfm) in polymicrogyria and cortical tubers using magnetic resonance (MR) perfusion imaging. Material and Methods: MR imaging and dynamic T2*-weighted MR perfusion imaging were performed in 13 patients with tuberous sclerosis complex, 10 with polymicrogyria, and 18 controls with developmental delay but no macroscopic brain abnormality. Regions of interest were placed in cortical tubers or polymicrogyric cortex and in the contralateral normal-appearing side in patients with malformations. In 'control' subjects, regions of interest were placed in the frontal and parietal lobes in both hemispheres. The rCBV and TTfm of the tuber/contralateral side (rCBVRTSC and TTFMTSC) as well as those of the polymicrogyria/contralateral side (rCBVRPMG and TTFMPMG) ...

2007-10-01

93

Inherited partial direct duplication of 11q: First report and possible association with a midline developmental field defect  

Energy Technology Data Exchange (ETDEWEB)

A 36-year-old woman underwent amniocentesis for advanced maternal age. The fetal karyotype had an extra dark staining G band on the long arm of chromosome 11 with no other identifiable abnormalities. FISH studies using a chromosome 11 paint probe confirmed the origin of the extra band. The abnormality was identified as a partial duplication of 11q: 46,XX dir dup (11)(q13.5q21) or (q21q23.1). The specific duplicated band could not be identified with certainty. Detailed fetal sonograms were normal. Family studies revealed the identical duplication in the mother but normal karyotypes in both maternal grandparents. The mother had strabismus and a short tongue frenulum which required surgical correction. Menses occurred late in adolescence and complete development of secondary sexual characteristics was delayed until adulthood. An infertility evaluation revealed duplication of the uterus, cervix, and vagina. An evaluation for metorrhagia identified ...

1994-09-01

94

Cardiac Malpositions  

International Nuclear Information System (INIS)

Cardiac Malposition refers to any position of the heart other than a left-sided heart in a situs solitus individual. Associated cardiac malformations are so complex that even angiocardiographic and autopsy studies may not afford an accurate information. Although the terms and classifications used to describe the internal cardiac anatomy and their arterial connections in cardiac malpositions differ and tend to be confusing, common agreement exists on the need for a segmental approach to diagnosis. Authors present 18 cases of cardiac malpositions in which cardiac catheterization and angiocardiography were done at the Department of Radiology, Seoul National University Hospital between 1971 and 1979. Authors analyzed the clinical, radiographic, operative and autopsy findings with the emphasis on the angiocardiographic findings. The results are as follows: 1. Among 18 cases with cardiac malpositions, 6 cases had dextrocardia ...

1979-06-01

95

AIDS and lung infection by Mycobacterium xenopi. Role of Computed Tomography  

International Nuclear Information System (INIS)

Mycobacterium xenopi is one of the most common agents responsible for nontubercolar mycobacterial pulmonary disease on AIDS patients. These lesions have been studied with conventional radiography while CT has been used in patients with a specific mycobacterioses or non-AIDS pulmonary conditions from Mycobacterium xenopi. 12 AIDS patients were examined. They had pulmonary lesions from Mycobacterium xenopi, patients age ranged 30 to 46 years. All patients had CD4 blood levels lower than 250 cells/mL and Mycobacterium xenopi in the sputum. All patients underwent a standard chest radiograph and a CT examination. CT images were evaluated by three radiologists independently and the definitive diagnosis was made in the presence of a fourth radiologist. Chest CT showed parenchymal consolidation in 66% of cases, associated with bilateral basal bands in 16% of cases. Consolidation was unilateral in 41% of cases and most frequently involved the right lower lobe. Bilateral ...

2000-06-01

96

Computed tomography and magnetic resonance imaging of acquired abnormalities of the inner ear and cerebello-pontine angle; CT und MRT erworbener Veraenderungen des Innenohrs und Kleinhirnbrueckenwinkels  

Energy Technology Data Exchange (ETDEWEB)

CT and MRI of acquired abnormalities of the inner ear and cerebello-pontine angle present themselves with very typical findings. The imaging should be adapted to the pathology looked for and either CT or MRI should be used alone or in combination.CT, especially high resolution CT (HRCT), provides an excellent bone contrast, while MRI has a much superior soft tissue contrast. Acute inflammatory changes of the inner ear are solely depicted by contrast-enhanced MRI. HRCT excellently depicts osseous changes of the inner ear and cerebellopontine angle such as chronic ossifying labyrinthitis occurring after acute labyrinthitis, otosclerotic or traumatic changes. Tumorous changes not yielding to bony changes are best delineated by MRI. Posttraumatic hemorrhage and chronic fibrotic changes within the labyrinth are depicted by MRI, only. In conclusion HRCT and MRI are excellent methods to delineate acquired abnormalities of the ...

2003-03-01

97

The allusive cognitive deficit in paranoia: the case for mental time travel or cognitive self-projection.  

Science.gov (United States)

Delusional beliefs are characteristic of psychosis and, of the delusions, the paranoid delusion is the single most common type associated with psychosis. The many years of research focused on neurocognition in schizophrenia, using standardized neurocognitive tests, have failed to find conclusive cognitive deficits in relation to positive symptoms. However, UK-based psychological research has identified sociocognitive anomalies in relation to paranoid thinking in the form of theory of mind (ToM), causal reasoning and threat-related processing anomalies. Drawing from recent neuroscientific research on the default mode network, this paper asserts that the common theme running through the psychological tests that are sensitive to the cognitive impairment of paranoia is the need to cognitively project the self through time, referred to as mental time travel. Such an understanding of the cognitive roots of paranoid ideation provides a synthesis between psychological and ...

2010-08-01

98

Localization of abnormal parathyroid glands using thallium-201  

Science.gov (United States)

Ectopically located parathyroid adenomas may be difficult to find during initial neck exploration. They account for over 70 percent of missed adenomas found at reexploration. Preoperative localization of parathyroid adenomas would reduce unnecessary dissection and possibly reduce the number of negative results of initial neck exploration. Before reoperative parathyroid surgery is performed, some means of localization is mandatory to detect ectopic adenomas in the neck and mediastinum. Computed tomography and ultrasonography cannot effectively evaluate the mediastinum. Angiography and venous parathyroid hormone sampling are invasive, costly, and tedious to perform. We have shown that thallium-201 will accurately localize ectopic parathyroid adenomas. All 10 adenomas found in positions not immediately adjacent to the thyroid gland were detected by thallium-201 scintigraphy. One was a mediastinal adenoma resected with a median sternotomy. Our results suggest that ...

1984-07-01

99

Intracranial tuberculoma: MR imaging  

International Nuclear Information System (INIS)

MR studies of 6 patients with intracranial tuberculoma are reviewed. All patients also underwent CT scans which showed hypo- or isodense lesions with abnormal enhancement following contrast administration. MR showed lesions with prolongation of the T1 relaxation time in every case. On the T2-weighted sequences, the signal properties of the tuberculoma varied according to the stage of evolution of the lesion. Incipient tuberculomas appeared as scattered areas of hypointensity surrounded by edema. Mature tuberculomas were composed of a dark necrotic center surrounded by an isointense capsule which was, in turn, surrounded by edema. In one patient, the center of the lesion was hyperintense probably because of liquefaction and pus formation (tuberculous abscess). While both, CT and MR, were equally sensitive in visualizing the intracranial tuberculoma in every patient, MR was slightly superior in demonstrating the extent of the lesion, especially for brainstem ...

1988-11-01

100

Evaluation of the hepatobiliary function with "9"9Tc"m EHIDA imaging during total parenteral nutrition  

International Nuclear Information System (INIS)

Fourteen surgical patients with non-hepatobiliary diseases were studied with "9"9Tc"m EHIDA imaging to evaluate the effect of total parenteral nutrition (TPN) on the hepatobiliary function. The duration of TPN ranged from 6 to 56 days; for 10 of the 14 patients it was between 6 to 10 days. The results showed that: (1) 11 of 14 patients had abnormal scintigraphic features. The most prominent findings were delayed liver excretion and prolonged blood clearance time. This fact suggests that not only the rate of excretion of the bile from the liver is decreased but the uptake ability of the hepatocyte is also impaired. (2) The effect of TPN on liver function is reversible. The authors conclude that in order to prevent irreversible damage of hepatobiliary function caused by TPN, the duration of TPN should not be too long and oral intake of nutrients should be resumed as soon as possible. (author). 9 refs, 3 figs, 3 tabs.

1988-08-15

101

Cholinergic systems in brain development and disruption by neurotoxicants: nicotine, environmental tobacco smoke, organophosphates  

International Nuclear Information System (INIS)

Acetylcholine and other neurotransmitters play unique trophic roles in brain development. Accordingly, drugs and environmental toxicants that promote or interfere with neurotransmitter function evoke neurodevelopmental abnormalities by disrupting the timing or intensity of neurotrophic actions. The current review discusses three exposure scenarios involving acetylcholine systems: nicotine from maternal smoking during pregnancy, exposure to environmental tobacco smoke (ETS), and exposure to the organophosphate insecticide, chlorpyrifos (CPF). All three have long-term, adverse effects on specific processes involved in brain cell replication and differentiation, synaptic development and function, and ultimately behavioral performance. Many of these effects can be traced to the sequence of cellular events surrounding the trophic role of acetylcholine acting on its specific cellular receptors and associated signaling cascades. However, for chlorpyrifos, additional ...

2004-07-15

102

Diffusion-and T2-weighted MR imaging of lipiodol induced cerebral infarcts in cat: early findings in the first 3 hours  

Energy Technology Data Exchange (ETDEWEB)

This study was designed to evaluate early parenchymal changes of acute cerebral is chemia/infarct by using T2-weighted, diffusion-weighted, and calculated apparent diffusion coefficient(ADC) MR imaging. The brain MR images were successfully obtained 30, 60, 90, 120, 150 and 180 minutes after intraarterial administration of Lipiodol (0.4-0.6ml) into the common carotid artery in 10 of 11 cats (91%). T2-and diffusion-weighted images and ADC were analyzed and compared with histopathologic findings. High signal intensity on T2-weighted and diffusion-weighted images was found in one cerebral hemisphere 30 minutes after Lipiodol injection, which tended to increase with time until 3 hours. Subcortical white matter showed higher signal intensity than cortical gray matter since 30 minutes after embolization. ADC images showed decreased signal intensity in the embolized hemisphere, which tended to decrease until 3 hours. Microscopic findings of the area ...

1997-06-01

103

Longitudinal changes in extended roles in radiography  

Energy Technology Data Exchange (ETDEWEB)

Purpose: The purpose of this research was to identify the extent and scope of changes to radiography practice. Method: Questionnaires were sent to radiology managers at acute National Health Service (NHS) hospitals in 2000 as a follow-up to an initial survey conducted in 1998. Information was sought on region, teaching/non-teaching status, the nature of extended role tasks undertaken and the year in which these tasks were first undertaken. Results: Some 172 questionnaires were returned from a total of 253 dispatched (68%). In 161 hospitals radiographers administered intravenous injections and performed barium enemas in 119 hospitals, while a red-dot system was in operation in 141 hospitals. Reporting by radiographers had increased since 1998. Replies indicated that, at 124 hospitals, radiographers were reporting in ultrasound. Skeletal reporting was the second most-frequently-reported activity, with 63 hospitals indicating ...

2002-11-01

104

Construction of a homogeneous phantom for radiographic image standardization; Construcao de um fantoma homogeneo para padronizacao de imagens radiograficas  

Energy Technology Data Exchange (ETDEWEB)

The principle of radiodiagnosis consists in the fact the X-ray beam is attenuated at different degrees by distinct tissues. For this reason, the anatomical structures have distinct radiological opacities, that produce the radiographic image. The progresses in radiology are related to the development if new radiographic image formation systems that enable an amplification in the quality, with low dose and/or risk to the patient. The objective of this work is the sensitometric valuation of a screen-film combination, that is still the most used, for the standardization, of radiographic images. Thinking about this, were constructed homogeneous phantoms of the chest, skull and pelvis, for the calibration of X-ray beams, with the purpose of obtaining radiographic images of good quality, basing in the routine of a radiodiagnosis service and in the scientific knowledge. Questions were approached about the ...

1996-12-31

105

Satisfaction of Search in Multi-trauma Patients: Severity of Detected Fractures  

UK PubMed Central (United Kingdom)

PurposeSatisfaction of search (SOS) occurs when an abnormality is missed because another abnormality has been detected. This research studied whether the severity...Full Text Available

2007-06-01

106

Prevalence of Renal Artery and Kidney Abnormalities by Computed Tomography among Healthy Adults  

UK PubMed Central (United Kingdom)

Background and objectives: Management of incidental renal artery and kidney abnormalities in patients undergoing computed tomography scans is a clinical challenge because their frequency in healthy...Full Text Available

2010-03-01

107

Ophthalmic abnormalities in patients with cutaneous T-cell lymphoma.  

UK PubMed Central (United Kingdom)

PURPOSE: To determine the frequency of ophthalmic abnormalities in patients with cutaneous T-cell lymphoma (mycosis fungoides and Sézary syndrome) and T-cell lymphoma involving the skin and...Full Text Available

1998-01-01

108

Macular abnormalities in the reattached retina.  

UK PubMed Central (United Kingdom)

Sixty-six patients in whom the macula was detached before surgery were observed for at least 1 year after retinal reattachment. Macular abnormalities were recognised clinically in most patients with...Full Text Available

1978-09-01

109

Intravitreal Avastin for Choroidal Neovascularization Associated with Stargardt-Like Retinal Abnormalities in Pseudoxanthoma Elasticum  

UK PubMed Central (United Kingdom)

The aim of the study was to describe a patient with pseudoxanthoma elasticum (PXE), showing Stargardt-like retinal abnormalities, who underwent treatment with intravitreal bevacizumab for subfoveal...Full Text Available

2010-10-01

110

Cystic fibrosis. 4. Abnormalities of airway epithelial function and the implications of the discovery of the cystic fibrosis gene.  

UK PubMed Central (United Kingdom)

Details of ion transporting abnormalities in cystic fibrosis airway epithelium are now known. The central hypothesis, that excessive drying of the airway surfaces is a primary event that leads to all...Full Text Available

1991-02-01

111

Abnormalities of GATA-1 in Megakaryocytes from Patients with Idiopathic Myelofibrosis  

UK PubMed Central (United Kingdom)

The abnormal megakaryocytopoiesis associated with idiopathic myelofibrosis (IM) plays a role in its pathogenesis. Because mice with defective expression of transcription factor GATA-1 (GATA-1low...Full Text Available

2005-09-01

112

ADEPT - Abnormal Doppler Enteral Prescription Trial  

UK PubMed Central (United Kingdom)

BackgroundPregnancies complicated by abnormal umbilical artery Doppler blood flow patterns often result in the baby being born both preterm and growth-restricted. These babies are...Full Text Available

113

Evaluation of digital radiography (Fuji computed radiography) for portable chest radiographs in ICU  

Energy Technology Data Exchange (ETDEWEB)

To evaluate the usefulness of portable chest radiographs by Fuji computed radiography (FCR) in ICU, FCR radiographs of 56 patients who were admitted to General Intensive Care Unit of Keio University Hospital were compared with the conventional portable images. Because FCR could show two differently processed images in one film and allowed a wide range of image reproduction, visualization of the trachea, bone soft tissues and catheters by FCR was easier than that by the conventional radiography. Repeated radiographs by FCR had similar optical densities and limited exposure errors. Furthermore, radiation was reduced than that of the conventional radiography. In conclusion, FCR is thought to be a useful technique for portable chest radiography in ICU patients. (author).

1992-12-01

114

Evaluation of digital radiography (Fuji computed radiography) for portable chest radiographs in ICU  

International Nuclear Information System (INIS)

To evaluate the usefulness of portable chest radiographs by Fuji computed radiography (FCR) in ICU, FCR radiographs of 56 patients who were admitted to General Intensive Care Unit of Keio University Hospital were compared with the conventional portable images. Because FCR could show two differently processed images in one film and allowed a wide range of image reproduction, visualization of the trachea, bone soft tissues and catheters by FCR was easier than that by the conventional radiography. Repeated radiographs by FCR had similar optical densities and limited exposure errors. Furthermore, radiation was reduced than that of the conventional radiography. In conclusion, FCR is thought to be a useful technique for portable chest radiography in ICU patients. (author).

1992-01-01

115

Cost Sensitivity Analysis for Radiology Department Planning  

UK PubMed Central (United Kingdom)

Two complementary computer programs have been developed for forecasting the demands and evaluating the costs of proposed radiographic facilities. The models are employed here in analyses of the sensitivity...Full Text Available

1971-01-01

116

Clinical evaluations of intra-arterial subtraction angiography using Fuji computed radiography  

International Nuclear Information System (INIS)

Intra-arterial subtraction angiography(IADSA) using Fuji computed radiography(FCR) was performed on 130 patients with cervical, pelvic, peripheral and abdominal diseases. It was compared with conventional angiography(radiographs produced by combining photographic film with an intensifying screen) performed on same patients. Radiographs produced by FCR were better than conventional radiographs in cervical, pelvic and peripheral angiography. In the abdominal angiography using FCR, there was misregistration artifact in some cases, but in hepatic angiography, the new radiographs under the injection of small amount of contrast medium(about 10ml) and the short exposure duration(about 10 seconds) were excellent. It was as valuable as conventional angiography (infusion hepatic angiography) for diagnosing hepatic neoplasms. (author).

1985-01-01

117

Aviation Maintenance Safety Articles, January/February 1990  

Science.gov (United States)

... These are abnormal and an indication of NAVAIRINST 13340.3 identifies these laboratories a possible breakdown in the fuel-handling equip- ...

1990-02-01

118

[Single and 4-week oral toxicity studies of prulifloxacin (NM441) in aged dogs].  

Science.gov (United States)

Single-dose and repeated dose toxicity studies of prulifloxacin, a new antibacterial agent, were conducted in aged beagle dogs. I. A single-dose toxicity study Prulifloxacin was administered orally to aged female dogs at a single dose of 2500 and 5000 mg/kg. No death occurred in any group. Vomiting was observed in one of two animals at 2500 mg/kg and in both animals at 5000 mg/kg 3-4 hr after dosing. At 5000 mg/kg, vomiting was observed in both animals after feeding on the day after dosing. One animal also showed soft stool. Thereafter, no abnormalities were observed in any animal. No test article related changes were noted in food consumption, water consumption, body weight or pathological examination in any group. The results show that the lethal dose of prulifloxacin is judged to be greater than 5000 mg/kg in aged female dogs. II. A repeated dose toxicity study Aged male and female dogs were given the test article orally for 4 weeks at doses of 0 (control), 20, ...

1996-06-01

119

Natural background radiation induces cytogenetic radioadaptive response more effectively than occupational exposure in human peripheral blood lymphocytes  

Science.gov (United States)

Ramsar, a city in the northern Iran, has the highest level of natural background radiation in the world. It has been clearly shown that low doses of ionising radiation can induce resistance to subsequent higher exposures. This phenomenon is termed radioadaptive response. We have compared induction of cytogenetic radioadaptive response by High Natural Background Radiation (HNBR) in Ramsar and X-ray occupational exposure as conditioning doses in human peripheral blood lymphocytes. 30 healthy control individuals, living in Ramsar but in normal background radiation areas, 15 healthy individuals from Talesh Mahalleh, a region with extraordinary high level of background radiation, and 7 X-ray radiographers working in Ramsar hospital located in normal natural background ionising radiation area were evaluated. Peripheral blood samples were prepared and exposed to challenge dose of 0 and 2 Gy. Lymphocytes were scored using analysis of metaphase, for the presence of ...

2003-01-01

120

Evaluation of calcification in pulmonary nodules using bone images obtained with single exposure energy subtraction  

Energy Technology Data Exchange (ETDEWEB)

Bone images obtained by single exposure dual energy subtraction with computed radiography, a new image processing method, were evaluated for the detectability of calcification in lung nodules in both phantom and clinical studies. In the phantom study, five simulated nodules containing known and uniformly distributed amounts of calcium hydroxide were placed in a human chest phantom and images were obtained the following five techniques: (1) conventional radiography (CXR), (2) low kV conventional radiography (Low), (3) Fuji computed radiography (FCR), (4) bone images with conventional singles exposure energy subtraction (ES) and (5) bone image with fine single exposure energy subtraction (FES). The detectability of calcification in the simulated nodules was evaluated by six radiologists using ROC analysis and two-way analysis of variance. In the clinical study, images of 42 lung nodules (21 calcified lung nodules and 21 non-calcified nodules), in which calcification was diagnosed by ...

1995-08-01

121

Evaluation of calcification in pulmonary nodules using bone images obtained with single exposure energy subtraction  

International Nuclear Information System (INIS)

Bone images obtained by single exposure dual energy subtraction with computed radiography, a new image processing method, were evaluated for the detectability of calcification in lung nodules in both phantom and clinical studies. In the phantom study, five simulated nodules containing known and uniformly distributed amounts of calcium hydroxide were placed in a human chest phantom and images were obtained the following five techniques: 1) conventional radiography (CXR), 2) low kV conventional radiography (Low), 3) Fuji computed radiography (FCR), 4) bone images with conventional singles exposure energy subtraction (ES) and 5) bone image with fine single exposure energy subtraction (FES). The detectability of calcification in the simulated nodules was evaluated by six radiologists using ROC analysis and two-way analysis of variance. In the clinical study, images of 42 lung nodules (21 calcified lung nodules and 21 non-calcified nodules), in which calcification was diagnosed by computed ...

1995-01-01

122

Two-phase fluid flow measurements in small diameter channels using real-time neutron radiography  

International Nuclear Information System (INIS)

A series of real-time, neutron radiography, experiments are ongoing at the Texas A and M Nuclear Science Center Reactor (NSCR). These tests determine the resolving capabilities for radiographic imaging of two phase water and air flow regimes through small diameter flow channels. Though both film and video radiographic imaging is available, the real-time video imaging was selected to capture the dynamic flow patterns with results that continue to improve. (author)

1994-04-05

123

Long-term changes in graft height after maxillary sinus floor elevation with different grafting materials: radiographic evaluation with a minimum follow-up of 4.5 years  

British Library Electronic Table of Contents (United Kingdom)

Abstract Objective: To compare the vertical dimensional changes with regard to graft height in a long-term follow-up in patients treated with two different grafting materials used in maxillary sinus floor elevation procedures. Material and methods: Twenty consecutive patients were included. One group was grafted with autogenous bone from the mandible (chin area), and the other group was augmented with a 100%b-tricalcium phosphate (b-TCP). During a 4- to 5-year period, in each patient, at least five panoramic radiographs were made. These panoramic radiographs were used for morphometric measurements, at three different locations. The three locations were the first bone to implant contact at the distal side of the second most posterior implant (L1), halfway between this implant and the most p...

2009-01-01

124

Obesity and periodontal disease  

UK PubMed Central (United Kingdom)

Obesity is characterized by the abnormal or excessive deposition of fat in the adipose tissue. Its consequences go far beyond adverse metabolic effects on health, causing an increase in oxidative stress,...Full Text Available

2010-04-01

125

Misfolded Proteins and Retinal Dystrophies  

UK PubMed Central (United Kingdom)

Many mutations associated with retinal degeneration lead to the production of misfolded proteins by cells of the retina. Emerging evidence suggests that these abnormal proteins cause cell death...Full Text Available

2010-01-01

126

MYELIN, COPPER, AND THE CUPRIZONE MODEL OF SCHIZOPHRENIA  

UK PubMed Central (United Kingdom)

In recent years increasing evidence is pointing toward white matter abnormalities in schizophrenia and other psychiatric disorders. The present paper will provide an overview over the role of...Full Text Available

127

MEDICAL FINAL REVIEW MEMORANDUM OF ORIGINAL BLA  

Science.gov (United States)

... The AAT Z mutation involves a single amino acid substitution (glutamine for lysine) at position 342, resulting in abnormal folding and polymerization of the ...

128

Idiopathic (primary) achalasia  

UK PubMed Central (United Kingdom)

Idiopathic achalasia is a primary esophageal motor disorder characterized by esophageal aperistalsis and abnormal lower esophageal sphincter (LES) relaxation in response to deglutition. It is a rare...Full Text Available

129

Abnormal chromosome repair and risk of developing cancer.  

UK PubMed Central (United Kingdom)

Several scientists have proposed that DNA repair deficiencies and the induction of a mutator phenotype are responsible for the generation of multiple mutagenic alterations in cancer cells. I propose...Full Text Available

1993-10-01

130

Structure of newly synthesized (/sup 35/S)-proteoglycans and (/sup 35/S)-proteoglycan turnover products of cartilage explant cultures from dogs with experimental osteoarthritis  

Energy Technology Data Exchange (ETDEWEB)

The structure of newly synthesized proteoglycans from explant cultures of cartilage from joints subjected to transection of the anterior cruciate ligament (osteoarthritic) and from normal (non- or sham-operated) joints was examined. The structure of the products of proteoglycan turnover was also examined using explants of normal and osteoarthritic cartilage maintained in culture for a 48 h chase period. The findings were as follows: Newly synthesized (/sup 35/S)-proteoglycans extracted from cartilage explants from osteoarthritic joints whether examined 3 weeks, 3 months, or 6 months after surgery were larger than those from corresponding normal cartilage. This can be explained by the synthesis in osteoarthritic cartilage of abnormally long chondroitin sulfate chains on newly synthesised proteoglycans. The extracts also contained a newly formed small proteoglycan species that was unable to interact with hyaluronic acid. The proportion of this ...

1985-01-01

131

Sequential changes in the femoral head after intracapsular fracture of the femoral neck. MRI findings  

International Nuclear Information System (INIS)

Authors obtained T1-weighted MRI images of the femoral head after fracture of the femoral neck and classified the signals into four patterns to investigate the sequential changes of the femoral head. The T1-weighted MRI images obtained initially after femoral neck fracture showed a normal pattern in 10 of the 15 hip joints studied. MRI images obtained subsequently still showed the normal signal pattern in eight of the 10 hip joints which had shown the normal pattern in the first MRI, while two of the 10 joints subsequently showed a band pattern. The joint with the homogeneous pattern in the first MRI subsequently showed a band pattern. Of the three joints with an inhomogeneous pattern in the first MRI, two joints showed a subsequent band pattern, and the other a normal pattern. The joints which showed a band pattern continued to show a similar band pattern. Eventually, all hip joints studied showed a normal or band pattern within six months after intracapsular fracture of the femoral ...

1998-07-01

132

Myocardial imaging in patients with Kawasaki disease. Exercise stress imaging and serial studies  

Energy Technology Data Exchange (ETDEWEB)

Thallium-201 myocardial imaging was performed in 80 children with coronary arterial lesions due to Kawasaki disease in order to assess the value of serial and exercise myocardial imagings. In eight of these children, abnormalities of the image were noted. Twenty children had serial thallium studies with an interval of three to 18 months, and five of these showed changes in the image including appearance of a new perfusion defect in one patient and improvement of perfusion defects in four. These changes of the myocardial image were correlated well with coronary angiographic findings obtained within a few days of the isotope studies. It was noted that the changes of the myocardial image were more frequently observed at relatively recent period recovered from Kawasaki disease. Exercise myocardial imaging using a bicycle ergometer was performed in eight children with coronary arterial lesions. In three an evidence of improvement of the myocardial ...

1982-06-01

133

Facet joint injuries in acute cervical spine trauma : evaluation with CT and MRI  

Energy Technology Data Exchange (ETDEWEB)

To evaluate injury patterns of facet joints and associated soft tissue injuries in patients with acute traumatic cervical facet joint injuries. From among patients with cervical spine trauma, 27 with facet joint injuries, as seen on CT and MRI, were chosen for this study. CT scans were analyzed with regard to the location of facet joint injury, the presence or absence of facet dislocation or fracture, and other associated fractures. MR images were analyzed with regard to ligament injury, intervertebral disc injury, intervertebral disc herniation, and spinal cord injury. The most common location of facet joint injury was C6-7 level(n=10), followed by C5-6(n=8). Among these 27 patients with facet joint injuries, 12(44%) had bilateral injuries and 15(56%) unilateral injuries. Facet fractures were present in 17 cases(63%) and the fracture of inferior facet was more frequent than superior. Patterns of fracture were vertical, transverse, or comminuted, but vertical fracture was the most ...

1999-05-01

134

Early and Late Bowel Complication Following Irradiation of Cancer of the Uterine Cervix-Whole Pelvis External Irradiation end High-Dose-Rate Interactively Irradiation  

International Nuclear Information System (INIS)

Cervix cancer is the most common female cancer in Korea. In spite of their relatively local invasive tendency, still 44% of patient will develop recurrent cancer This result suggests that more aggressive local treatment may increase the cure rate but increased complication risk also cannot be avoidable. Various institutions proposed different treatment regimen, but recommended dose were about 4500 cGy for whole pelvis and 8000 cGy at point A, even though they agreed that those doses may not be satisfactory for control of bulky disease. 96 cases of invasive cervical cancer, treated with postoperative or primary radiation therapy were analyzed to determine the complication rate and prognostic factor in our treatment regimen which is 500-1000 cGy higher than other institution. Mean follow up duration was 21 months. Symptomatic patients including mild but persistent abdominal discomfort was 46%, but only 1 patient (1%) had operative treatment because of incomplete obstruction of small ...

1989-06-01

135

Computed tomograms of the newborn  

International Nuclear Information System (INIS)

Computed tomograms (CT) from 204 cases of premature and full term infants were studied. 1) In 70 infants of hyaline membrane disease, primary apnea and asymptomatic transient hypoglycemia and hypocalcemia, without any abnormal CT findings such as intracranial hemorrhage, periventricular lucency was found in 65 cases (93%) and a wide extracerebral space of the temporal lobes was found in 60 cases (86%) before 44 weeks of gestation. A wide interhemispheric fissure was found in 11 cases of extremely premature infants before term. Periventricular lucency and a wide extracerebral space of temporal lobes may not be the result of the intracranial pathological changes, but they may represent a stage of brain development. 2) In 204 cases, intracranial hemorrhage was found in 39 cases; intra ventricular 14 cases, subependymal 2 cases, intracerebral 4 cases, subarachnoid 19 cases. CT was useful in evaluating the site and extent of hemorrhage. Among 14 ...

136

Aarskog-Scott syndrome: Clinical update and report of nine novel mutations of the FGD1 gene  

DEFF Research Database (Denmark)

Mutations in the FGD1 gene have been shown to cause Aarskog-Scott syndrome (AAS), or facio-digito-genital dysplasia (OMIM#305400), an X-linked disorder characterized by distinctive genital and skeletal developmental abnormalities with a broad spectrum of clinical phenotypes. To date, 20 distinct mutations have been reported, but little phenotypic data are available on patients with molecularly confirmed AAS. In the present study, we report on our experience of screening for mutations in the FGD1 gene in a cohort of 60 European patients with a clinically suspected diagnosis of AAS. We identified nine novel mutations in 11 patients (detection rate of 18.33%), including three missense mutations (p.R402Q; p.S558W; p.K748E), four truncating mutations (p.Y530X; p.R656X; c.806delC; c.1620delC), one in-frame deletion (c.2020_2022delGAG) and the first reported splice site mutation (c.1935+3A>C). A recurrent mutation (p.R656X) was detected in three independent families. ...

2010-01-01

137

Spinous process palpation using the scapular tip as a landmark vs a radiographic criterion standard  

UK PubMed Central (United Kingdom)

AbstractObjectiveThis study aimed at determining the standing spinal landmark that corresponds to the inferior tip of the scapula and determining the accuracy of experienced...Full Text Available

2007-01-01

138

Radiographic monitoring of incidental abdominal aortic aneurysms: a retrospective population-based cohort study  

UK PubMed Central (United Kingdom)

BackgroundAn abdominal aortic aneurysm (AAA) that is identified when the abdomen is imaged for some other reason is known as an incidental AAA. No population-based studies have...Full Text Available

139

Radiographic experience with power transmission equipment  

Energy Technology Data Exchange (ETDEWEB)

This paper describes radiography as one of the most efficient and cost effective methods for inspecting electric cabls. Details of one project in particular, i.e., the inspection of high-pressure, oil-filled, pipe-type cables (HPOF) are given. 2 refs.

1980-01-01

140

Radiation exposure of children in pediatric radiology. Pt. 6. Conversion factors for reconstruction of organ dose in abdominal radiography; Zur Strahlenexposition von Kindern in der paediatrischen Radiologie. T. 6. Konversionsfaktoren zur Rekonstruktion von Organdosen bei Abdomenaufnahmen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: calculation of conversion coefficients for the reconstruction of organ doses from entrance doses for abdomen radiographs of 0, 1, 5, 10, 15, and 30-year-old patients in conventional pediatric radiology for the radiographic settings recommended by the German and European guidelines for quality management in diagnostic radiology. Materials und method: using the commercially available personal computer program PCXMC developed by the Finnish Center for Radiation and Nuclear Safety (Saeteilyturvakeskus STUK), conversion coefficients for conventional abdomen radiographs were calculated performing Monte Carlo simulations in mathematical hermaphrodite phantom models describing patients of different ages. The possible clinical variation of beam collimation was taken into consideration by defining optimal and suboptimal radiation fields on the phantoms' surfaces. Results: conversion coefficients for the ...

2009-10-15

141

Positional Stretching of the Coracohumeral Ligament on a Patient with Adhesive Capsulitis: A Case Report  

UK PubMed Central (United Kingdom)

Idiopathic frozen shoulder is a common medical diagnosis for patients seeking physical therapy. Radiographic and surgical evidence exists that describes the coracohumeral ligament (CHL) as a major contributor...Full Text Available

2009-01-01

142

Late metastasis from neuroblastoma mimicking Ewing's sarcoma  

International Nuclear Information System (INIS)

The case of an unusual late metastasis of neuroblastoma to the calcaneum, appearing as a sole recurrence 9 years after surgery, is reported. The radiographic features of the osseous lesion were very suggestive of primary bone malignancy, Ewing's sarcoma as the first option, with extraosseous spread to the soft tissues. (orig.).

143

Iodixanol in cerebral computed tomography: a randomized, double-blind, phase-III, parallel study with iodixanol and iohexol  

International Nuclear Information System (INIS)

Iodixanol is a new nonionic dimer, isotonic with blood at all clinically relevant concentrations. Iodixanol (270 mg I/ml) was compared in a double-blind, randomized, parallel-group, phase-III study to the monomeric nonionic iohexol (300 mg I/ml) for evaluation of safety, tolerability and radiographic efficacy during cerebral CT. One hundred adult patients scheduled to undergo contrast-enhanced cerebral CT were randomly allocated to receive either iodixanol or iohexol. All completed the trial. Safety was evaluated by recording discomfort and other adverse events, tolerance by assessing intensity and incidence of discomfort. Radiographic efficacy was assessed from the diagnostic information and the radiographic density. No serious adverse events occurred. One patient (2 %) in the iodixanol group and one patient (2 %) in the iohexol group experienced a transient reddening at the neck and lower neck-line, respectively. Both ...

1999-09-01

144

Ewing's sarcoma presenting as a solitary cyst  

International Nuclear Information System (INIS)

This case describes a 10-year-old girl who developed a Ewing's sarcoma in her proximal fibula. The radiologic features mimicked those of a unicameral bone cyst. The presence of pain and the atypical location led to a prompt biopsy and the correct diagnosis. The mechanism of this unusual radiographic presentation is discussed. (orig.)

2006-07-01

145

Changes in inflammatory mediators in experimental periodontitis in the rhesus monkey.  

UK PubMed Central (United Kingdom)

Ligature-induced periodontitis was monitored for 6 months in eight Macaca mulatta monkeys to examine clinical status, radiographic bone level, and crevicular fluid (CF) levels of prostaglandin E2 (PGE2),...Full Text Available

1993-04-01

146

Case series of maxillary sinus augmentation with biphasic calcium phosphate: a clinical and radiographic study  

UK PubMed Central (United Kingdom)

PurposeThe aim of this study was to evaluate 3.5 years-cumulative survival rate of implants placed on augmented sinus using Osteon, a bone graft material, and to assess the height...Full Text Available

2011-04-01

147

Candidate salivary biomarkers associated with alveolar bone loss: cross-sectional and in vitro studies  

UK PubMed Central (United Kingdom)

This cross-sectional study evaluated the association between radiographic evidence of alveolar bone loss and the concentration of host-derived bone resorptive factors (interleukin-1 beta, tumor...Full Text Available

2007-03-01

148

A Comparison of intra-oral digital imaging modalities: Charged Couple Device versus Storage Phosphor Plate  

UK PubMed Central (United Kingdom)

BackgroundThis in vitro study was conducted to compare the accuracy of two digital image receptors in identifying the location of tip of a fine endodontic file and radiographic apex...Full Text Available

2010-11-01

149

Staging of osteochondritis dissecans of the knee and ankle with MRI. Comparison with conventional radiography and arthroscopy; Die Stadienbestimmung der Osteochondrosis dissecans am Knie- und Sprunggelenk mit der MRT. Vergleich mit konventioneller Radiologie und Arthroskopie  

Energy Technology Data Exchange (ETDEWEB)

A prospective study was performed on 50 patients suffering from osteochondritis dissecans of the knee and ankle to define criteria for stability and fixation of osteochondral lesions. Morphological parameters in MRI (size, fragmentation, cartilage, interface) and conventional radiology (separation, fragmentation) were registered and compared with arthroscopical staging. MRI staging based on different types of interfaces was demonstrated on T{sub 1}- and T{sub 2}-weighted images. MRI could correctly predict a Grade 1 lesion in 50%, a Grade 2 lesion in 90%, a Grade 3 lesion on 0%, and a Grade 4 lesion in 79%. Stable lesions were differentiated from unstable lesions in 90%. Radiographic findings corresponded with arthroscopic staging in only 56% of the cases because fibrotic connection may guarantee stability in case of bony separation. (orig./MG) [Deutsch] In einer prospektiven Studie an 50 Patienten mit einer Osteochondrosis dissecans (OD) des ...

1995-07-01

150

Primary Ewing's sarcoma of the vertebral column  

International Nuclear Information System (INIS)

To determine the demographics, imaging findings, clinical symptoms, and prognosis of primary vertebral Ewing's sarcoma (PVES). A retrospective review of medical records and radiological studies of patients diagnosed with PVES from 1936 through 2001 in our institution and Department of Pathology consultation files was undertaken. Metastatic and soft tissue Ewing's sarcoma cases were excluded. From a total of 1,277 cases of Ewing's sarcoma, 125 (9.8%) had a primary vertebral origin. There were 48 females and 76 males. Patient ages ranged from 4 to 54 (mean 19.3, standard deviation 10.7, median 16) years. Vertebral column distribution was four cervical (3.2%), 13 thoracic (10.5%), 31 lumbar (25%), and 67 sacrum (53.2%). More than one vertebral segment was involved in ten cases (8%). Satisfactory imaging studies were available in 51 patients: 49 radiographs, 27 computerized tomography (CT), and 23 magnetic resonance imaging (MRI) studies. The ...

2004-09-01

151

Dosimetry limitations and a dose correction methodology for step-and-shoot IMRT  

Energy Technology Data Exchange (ETDEWEB)

For the step-and-shoot intensity-modulated radiation therapy (IMRT) technique, the combination of high dose rate, multiple beam segments and low dose per segment can lead to significant differences between the planned dose and the dose delivered to the patient. In this technique, a dose delivery inaccuracy known as the 'overshoot' effect is caused by the dose servo control system. This typically occurs in the first and last beam segments and causes an over- and underdose, respectively. Some dose positional error in the segment sequence is also possible there. Commercial ionization chambers (RK-type) and radiographic Kodak films were used for the measurements. The reported results were obtained using the Pinnacle{sup 3}-V6.2 treatment planning system and a Varian Clinac 21 EX linear accelerator equipped with a 120-leaf Millennium MLC. The dose inaccuracy measurements were based on the comparison of the dose and profiles for reference fields and ...

2006-02-07

152

Intermediate form of osteopetrosis with recessive inheritance  

International Nuclear Information System (INIS)

The clinical and radiographic features of the intermediate form of osteopetrosis in two sibs are presented in which the disorder appears to have been inherited as a recessive trait. Although this form of osteopetrosis has been poorly delineated, its recognition is practically important in order to give an accurate prognosis. This paper also presents an unusual complication of bilateral avascular necrosis of the femoral head in the younger sib. Radiographic changes of the femoral heads suggest those of Legg-Calve-Perthes disease, though the possibility of avascular necrosis following unrecognized femoral neck fracture is not completely excluded. (orig.).

153

A somatic dose index for diagnostic radiology  

International Nuclear Information System (INIS)

Irradiation of the human body in diagnostic X-ray procedures results in different absorbed doses in the various body organs. A somatic dose index in formulated by applying the relative sensitivity of the human to each of the most important somatic effects and utilizing the absorbed dose in the affected organs. This quantity is used to convey a cumulative somatic impact and is computed for common radiographic views in diagnostic radiology as a function of beam quality for a nominal IR entrance exposure. Using typical X-ray beam qualities and exposures, the frequency of the various radiographic views that make up an examination and the frequencies of the various examinations in the national population, illustrative examples of the application of the somatic dose index are presented. (author).

1978-01-01

154

Visual search behaviour in skeletal radiographs: a cross-speciality study  

Energy Technology Data Exchange (ETDEWEB)

Aim: To determine whether experience improves the consistency of visual search behaviour in fracture identification in plain radiographs, and the effect of specialization. Material and methods: Twenty-five observers consisting of consultant radiologists, consultant orthopaedic surgeons, orthopaedic specialist registrars, orthopaedic senior house officers, and accident and emergency senior house officers examined 33 skeletal radiographs (shoulder, hand, and knee). Eye movement data were collected using a Tobii 1750 eye tracker with levels of diagnostic confidence collected simultaneously. Kullback-Leibler (KL) divergence and Gaussian mixture model fitting of fixation distance-to-fracture were used to calculate the consistency and the relationship between discovery and reflective visual search phases among different observer groups. Results: Total time spent studying the radiograph was not significantly different between the ...

2007-11-15

155

Liver function abnormalities and outcome in patients with chronic heart failure: data from the Candesartan in Heart Failure: Assessment of Reduction in Mortality and Morbidity (CHARM) program  

UK PubMed Central (United Kingdom)

AimsThe prevalence and importance of liver function test (LFT) abnormalities in a large contemporary cohort of heart failure patients have not been systematically evaluated.Full Text Available

2009-02-01

156

Yost finds yet another reason to be paranoid  

CERN Document Server

Yost finds yet another reason to be paranoid

2008-01-01

158

Study on the time-domain electromagnetic responses; TDEM ho ni okeru denji oto ni tsuite  

Energy Technology Data Exchange (ETDEWEB)

With an objective to perform three-dimensional analysis with high accuracy in using the electromagnetic exploration method, characteristics in electromagnetic response were analyzed, and conditions for acquiring necessary data were discussed. The discussion defined a parameter called `response anomaly` which uses response from media to standardize response only from substances with abnormal resistivity. The receivers were located uniformly on the same plane, and the response anomaly was derived from electromagnetic response from each of the three horizontal and vertical components at each receiving point, which was expressed as a contour map. The parameter for the abnormal body was consisted of location and resistivity contrast with media. Discussions using the contour map were given on the response when these factors for the parameter were varied. As a result, it was found that the response anomaly appears in the form that reflects the ...

1997-05-27

159

Dynamic quantitative bone scintigraphy in patients with prostatic carcinoma treated by orchiectomy  

International Nuclear Information System (INIS)

Dynamic quantitative bone scintigraphy was performed on 31 men with prostatic carcinoma before orchiectomy as well as 2 weeks, 2 and 6 months postoperatively. After injection of technetium methylene diphosphonate Tc 99m ("9"9"mTc-MDP) the count rate was recorded as serial images over the lower thoracic and all the lumbar vertebrae from 1 to 240 min post-injection. Thirteen men had normal bone scintigrams with no changes in "9"9"mTc-MDP content at the four different investigation times. Eighteen men had skeletal metastases. Throughout the study half of the abnormal vertebrae in these patients showed an abnormal count rate after only 6 min post-injection. After 1 h it was possible in almost all abnormal vertebrae to predict abnormal bone uptake. In response to therapy a 'flare phenomenon' with an increase in count rate was seen 2 weeks after orchiectomy followed by a decrease 2 months postoperatively in ...

160

Helical CT of traumatic injuries of the thoracic aorta; Applicazioni della Tomografia Computerizzata spirale nello studio delle lesioni traumatiche dell'aorta toracica  

Energy Technology Data Exchange (ETDEWEB)

Acute thoracic aortic injuries account for up to 10-20% of fatalities in high-speed deceleration road accidents and have an estimated immediate fatality rate of 80-90%. Untreated survivors to acute trauma (10-20%) have a dismal prognosis: 30% of them die within 6 hours, 40-50% die within 24 hours, and 90% within 4 months. It was investigated the diagnostic accuracy of Helical Computed Tomography (Helical CT) in acute traumatic injuries of the thoracic aorta, and the role of this technique in the diagnostic management of trauma patients with a strong suspicion of aortic rupture. It was compared retrospectively the chest Helical CT findings of 256 trauma patients examined June 1995 through August 1999. Chest Helical CT examinations were performed according to trauma score, to associated traumatic lesions and to plain chest radiographic findings. All the examinations were performed with no intravenous contrast agent ...

2000-09-01

161

The Prognostic Significance of p53, Bcl-2, Cytokeratin 20 and Ki-67 in Primary Superficial Papillary Transitional Bladder Carcinoma  

International Nuclear Information System (INIS)

Identification of factors that determine individual patient risk for recurrence and progression in superficial papillary carcinoma of the bladder is a subject of extensive research as it would be a major outcome in patient management. It has been well recognized that traditional prognostic markers as tumor grade and stage are not accurate enough in predicting biological behavior. A large number of markers have been investigated as potential prognostic factors and relatively few can help in predicting outcome. Material and Methods: Forty-nine cases undergoing complete transurethral resection for primary superficial papillary transitional cell carcinoma were subjected to clinicopathologic evaluation as well as immunohistochemical staining for p53, bcl-2, cytokeratin 20 and Ki-67. The CAS-200 image analyzer was used to estimate the Ki-67 labeling index. Results: Recurrence was observed in 19 cases (38.8%) and progression in 7 cases (14.3%) with a median followup of 49 months (range 24-84 ...

2003-03-01

162

Role of Spiral and Multislice Computed Tomography in the evaluation of traumatic and spontaneous oesophageal perforation. Our experience  

International Nuclear Information System (INIS)

Purpose: To assess the role of CT in the evaluation of traumatic and spontaneous oesophageal perforation. Materials and methods: From March 2001 to May 2003, we studied 12 patients (7 males and 5 females; age range: 25-66 years, mean age: 43.5 years) with suspected oesophageal perforation due to motor-vehicle accidents (4 cases), stab wound (one case), post-intubation (2 cases), foreign body ingestion (2 cases) and spontaneous (3 cases). Five patients underwent standard chest and cervical radiography; two patients with suspected foreign body ingestion also underwent a gastrografin swallow study; all of the 12 patients underwent CT of the neck, chest and abdomen before and after intravenous, and in four cases oral, administration of contrast material. Results: In 5 patients with cervical, thoracic and abdominal trauma, the CT examination showed the presence of pleuroparenchymal injury (pneumothorax, pleural effusion and subcutaneous emphysema) as well as findings ...

2005-03-01

163

Neutron-computer tomography using real-time neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

A real-time neutron radiography facility was constructed including the capability of neutron tomography. The neutron beam was measured for total neutron flux ((1.0 +/- 0.2) x 10/sup 11/ m/(m/sup 2/-sec)), gold cadmium ratio (52 +/- 3) and effective neutron temperature (83/sup 0/C +/- 8/sup 0/C). The angular divergence or nonparallelism of the neutron beam was measured to be 2.3/sup 0/ +/- 0.1/sup 0/ thereby providing a means of quantifying the collimator effectiveness. The resolution capabilities of both static film and real-time neutron radiographs were quantified using a Fourier transform algorithm to calculate the modulation transfer function of both types of radiographs. The contrast sensitivity of both types of radiographs. The contrast sensitivity of both types of radiographs was measured as 3.1% for film and 4.0% for real-time radiographs. Two tomography algorithms, the ...

1986-01-01

164

Neutron-computer tomography using real-time neutron radiography  

International Nuclear Information System (INIS)

A real-time neutron radiography facility was constructed including the capability of neutron tomography. The neutron beam was measured for total neutron flux ((1.0 +/- 0.2) x 10"1"1 m/(m"2-sec)), gold cadmium ratio (52 +/- 3) and effective neutron temperature (83"0C +/- 8"0C). The angular divergence or nonparallelism of the neutron beam was measured to be 2.3"0 +/- 0.1"0 thereby providing a means of quantifying the collimator effectiveness. The resolution capabilities of both static film and real-time neutron radiographs were quantified using a Fourier transform algorithm to calculate the modulation transfer function of both types of radiographs. The contrast sensitivity of both types of radiographs. The contrast sensitivity of both types of radiographs was measured as 3.1% for film and 4.0% for real-time radiographs. Two tomography algorithms, the simultaneous iterative ...

1986-01-01

165

Evaluation of node involvement in non small cell bronchogenic carcinoma. CT-pathology correlation  

International Nuclear Information System (INIS)

The main purpose of this work is to evaluate the role of CT in identifying other morphological signs of met static lymph node involvement from non small cell bronchogenic carcinoma. This is done to improve N staging, a critical step in this disease. In fact, since diameter is the only criterion used to distinguish normal form abnormal lymph nodes, mediastinal CT only has 80% diagnostic accuracy. 137 patients with known or suspected lung cancer were examined with Helical CT during early and late arterial phases (2 min. delay, 3 mm thickness, 5 mm inter slice gap) to depict node characteristics. Mediastinal lymph nodes, located according to the American Thoracic Society mapping, were considered normal when they were not visible or, if visible, less than 1 cm in diameter and of homogeneous density; lymph nodes over 1 cm in diameter and homogenous density were considered reactive. A lymph node was considered metastatic when, independent of size, the following signs ...

2000-05-01

166

Tetracycline treatment of periodontal disease in the beagle dog  

Energy Technology Data Exchange (ETDEWEB)

Bone-seeking radiopharmaceutical uptake (BSRU) was used to examine alveolar bone metabolism in a longitudinal study of tetracycline efficacy in beagle dogs. BSRU was measured in untreated control dogs and in beagles receiving either 250 mg or 500 mg oral tetracycline-HCl daily for 16 months. The rate of bone loss was determined for radiographs taken semiannually for a 6-month pretreatment period and for a 24-month treatment period. Measurements of BSRU obtained at month 16 of treatment were correlated with rates of bone loss determined radiographically in an attempt to determine whether BSRU was indicative of the subsequent rate of bone loss. A reduced rate of alveolar bone loss was found in the 500 mg tetracycline group at month 16 of the study relative to the untreated controls which was consistent with the decreased bone-seeking radiopharmaceutical uptake observed in this group. A significantly increased BSRU (p<.0001) was found in the ...

1982-01-01

167

A study of the effects of scattered radiation on radiographic quality and methods of elimination of such radiation  

International Nuclear Information System (INIS)

Many mechanical parts are subjected to stresses and strains that may eventually lead to their failure. In order to prevent the costly delays associated with equipment down-time, many parts have to be tested for weaknesses and defects when machinery is constructed or dismantled for maintenance. These procedures are known as Non-Destructive Testing (NDT) methods. Five types of non-destructive testing methods routinely used are radiographic testing, ultrasonic testing, magnetic particle inspection, liquid penetrant testing and eddy current testing. Out of these five techniques industrial radiography plays an important role in non-destructive testing to reveal interior defects in materials. In radiography almost two-thirds of the radiation reaching the film is scattered radiation which does not form the image of defects. Scattered radiation generated inside and outside a material has a very large effect on sensitivity of flaw detection since it reduces image contrast. ...

1998-02-01

168

Soft tissue manifestations of early rheumatic disease. Imaging with MRI; Fruehmanifestationen rheumatischer Gelenkerkrankungen an den Weichgewebestrukturen der Hand. Nachweis mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

The aim of this study was to evaluate typical magnetic resonance imaging (MRI) findings in early rheumatic diseases manifesting at the soft tissues of the hand using a retrospective analysis. A total of 186 MRI examinations of patients with clinical suspicion of a rheumatic disease were evaluated in a consensus reading by two experienced radiologists. All imaging patterns were assessed with respect to their type and localization. Under blinded and non-blinded conditions diagnoses were correlated with final clinical diagnosis. The most frequent diagnoses were rheumatoid arthritis (RA, 45.7%) and psoriatic arthritis (PsA, 15.6%). The mean correlation between clinical and MRI diagnosis (r) was 0.75 in blinded and 0.853 in non-blinded reading (p <0.001). The following extra-articular imaging patterns were found: synovitis (59.1%), tendovaginitis (91.4%), dactylitis (14.5%), and bone marrow edema (18.3%). Only dactylitis was specific for a particular rheumatic ...

2006-08-15

169

Untreated Poor Vision: A Contributing Factor to Late-Life Dementia  

UK PubMed Central (United Kingdom)

Ophthalmologic abnormalities have been described in patients with dementia, but the extent to which poor vision and treatment for visual disorders affect cognitive decline is not well defined. Linked...Full Text Available

2010-03-15

170

Type I Collagen Is a Genetic Modifier of Matrix Metalloproteinase 2 in Murine Skeletal Development  

UK PubMed Central (United Kingdom)

Recessive inactivating mutations in human matrix metalloproteinase 2 (MMP2, gelatinase A) are associated with syndromes that include abnormal facial appearance, short stature, and severe bone...Full Text Available

2007-06-01

171

Total prosthetic replacement of atrioventricular valves in the dog  

UK PubMed Central (United Kingdom)

The metal parts of cardiac valve prostheses cause reactions in the surrounding tissues of the heart. In some dogs rather abnormal reactions were found, and were attributed to corrosion of the stainless...Full Text Available

1972-01-01

172

The Induction of APC with a Distinct Tolerogenic Phenotype via Contact-Dependent STAT3 Activation  

UK PubMed Central (United Kingdom)

BackgroundActivation of the signal transducer and activator of transcription 3 (STAT3) within antigen presenting cells (APCs) is linked to abnormal APCs differentiation and function....Full Text Available

173

Tear Lipocalin Captures Exogenous Lipid from Abnormal Corneal Surfaces  

UK PubMed Central (United Kingdom)

Purpose.The cornea is protected by apical hydrophilic transmembrane mucins and tears. In pathologic states the mucin barrier is disrupted, creating potential for meibomian lipids...Full Text Available

2010-04-01

174

Structural aberrations in group A Staphylococcus bacteriophages.  

UK PubMed Central (United Kingdom)

Six related Staphylococcus phages spontaneously produced various abnormal head and tail structures: (i) giant capsids which were tailed and apparently contained nucleic acid; (ii) regular and irregular...Full Text Available

1976-05-01

175

Renal functions in pediatric patients with beta-thalassemia major: relation to chelation therapy: original prospective study  

UK PubMed Central (United Kingdom)

BackgroundIn β-thalassemia, profound anemia and severe hemosiderosis cause functional and physiological abnormalities in various organ systems. In recent years, there have...Full Text Available

176

Rapid oscillations in omental lipolysis are independent of changing insulin levels in vivo  

UK PubMed Central (United Kingdom)

Abnormal fat metabolism plays an important role in the pathogenesis of obesity-related type 2 diabetes mellitus. This study examined whether free fatty acid levels (FFAs), like insulin levels, oscillate...Full Text Available

2000-08-01

177

Radionuclide imaging of the acutely painful scrotum  

International Nuclear Information System (INIS)

This paper discusses the clinical application and main objective of testicular imaging. The authors present cases that represent a spectrum of the abnormalities which might be detected by testicular imaging, with special attention given to testicular torsion and the acute diseases which may mimic it clinically. Accuracy of the test is noted.

178

Progressive ratio performance following challenge with antipsychotics, amphetamine, or NMDA antagonists in adult rats treated perinatally with phencyclidine  

UK PubMed Central (United Kingdom)

RationalePrevious research has shown that rats exposed perinatally to phencyclidine (PCP) exhibited neuroanatomical abnormalities and altered cognition. In addition...Full Text Available

2004-12-01

179

Patent arterial duct  

UK PubMed Central (United Kingdom)

Patent arterial duct (PAD) is a congenital heart abnormality defined as persistent patency in term infants older than three months. Isolated PAD is found in around 1 in 2000 full term infants. A higher...Full Text Available

180

Normal Coronary Artery Patient Presenting with Left Ventricular Aneurysm  

UK PubMed Central (United Kingdom)

Left ventricular aneurysm (LVA) is one of the most important complications of myocardial infarction LVA is strictly defined as a distinct area of abnormal left ventricular diastolic contour with systolic...Full Text Available

2011-01-01

181

Nonsteroidal Anti-Inflammatory Drugs for Wounds: Pain Relief or Excessive Scar Formation?  

UK PubMed Central (United Kingdom)

The inflammatory process has direct effects on normal and abnormal wound healing. Hypertrophic scar formation is an aberrant form of wound healing and is an indication of an exaggerated function of...Full Text Available

2010-01-01

182

Neoplastic transformation of prostatic and urogenital epithelium by the polyoma virus middle T gene.  

UK PubMed Central (United Kingdom)

Male transgenic mice expressing the polyomavirus middle T (PyV-MT) gene exhibited growth and developmental abnormalities in prostatic and other urogenital epithelium. Expression of PyV-MT was directed...Full Text Available

1996-10-01

183

Myelination of the corpus callosum in male and female rats following complex environment housing during adulthood  

UK PubMed Central (United Kingdom)

Myelination is an important process in brain development, and delays or abnormalities in this process have been associated with a number of conditions including autism, developmental delay,...Full Text Available

2009-09-08

184

Management of complex lipid abnormalities with a fixed dose combination of simvastatin and extended release niacin  

UK PubMed Central (United Kingdom)

ER niacin combined with simvastatin provides an additional option for achieving LDL-C and non-HDL-C goals for cardiovascular prevention, with greater efficacy in those with triglyceride levels >200...Full Text Available

2009-01-01

185

Mammalian life-span determinant p66shcA mediates obesity-induced insulin resistance  

UK PubMed Central (United Kingdom)

Obesity and metabolic syndrome result from excess calorie intake and genetic predisposition and are mechanistically linked to type II diabetes and accelerated body aging; abnormal nutrient and insulin...Full Text Available

2010-07-27

186

Magnetic iron compounds in the human brain: a comparison of tumour and hippocampal tissue  

UK PubMed Central (United Kingdom)

Iron is a central element in the metabolism of normal and malignant cells. Abnormalities in iron and ferritin expression have been observed in many types of cancer. Interest in characterizing iron compounds...Full Text Available

2006-12-22

187

Knockdown of Bicaudal C in Zebrafish (Danio rerio) Causes Cystic Kidneys: A Nonmammalian Model of Polycystic Kidney Disease  

UK PubMed Central (United Kingdom)

Polycystic kidney disease (PKD) is one of the leading causes of end-stage renal disease in humans and is characterized by progressive cyst formation, renal enlargement, and abnormal tubular development....Full Text Available

2010-04-01

188

Is alopecia areata an autoimmune-response against melanogenesis-related proteins, exposed by abnormal MHC class I expression in the anagen hair bulb?  

UK PubMed Central (United Kingdom)

The etiology of alopecia areata (AA), a putative autoimmune disease characterized by sudden hair loss, has remained obscure. It is not understood, how the characteristic inflammatory infiltrate that...Full Text Available

1993-11-01

189

Interrelationships between postpartum events, hormonal therapy, reproductive abnormalities and reproductive performance in dairy cows: a path analysis.  

UK PubMed Central (United Kingdom)

Path analysis was used to determine the interrelationships between postpartum administration of gonadotrophin releasing hormone and cloprostenol and the occurrence of reproductive disease and reproductive...Full Text Available

1985-07-01

190

Genetic Modulation of GABA Levels in the Anterior Cingulate Cortex by GAD1 and COMT  

UK PubMed Central (United Kingdom)

γ-Aminobutyric acid (GABA)-ergic transmission is critical for normal cortical function and is likely abnormal in a variety of neuropsychiatric disorders. We tested the in...Full Text Available

2010-07-01

191

Gamuts in nuclear medicine  

Energy Technology Data Exchange (ETDEWEB)

This book provides differential diagnostic possibilities of specific scan abnormalities in one volume for easy reference. This book is organized by organ systems and covers the central nervous system, the endocrine, skeletal, pulmonary, gastrointestinal, genitourinary, and cardiovascular systems. The gamuts are designed to teach differential diagnosis and to assist in the actual interpretation of patient slides.

1983-01-01

192

Focal structural changes and cognitive dysfunction in juvenile myoclonic epilepsy  

UK PubMed Central (United Kingdom)

Objective:The aim of this study was to determine if there were focal cortical abnormalities in juvenile myoclonic epilepsy (JME) using neuropsychological investigations and MRI.Methods:Twenty-eight...Full Text Available

2011-01-04

193

Endogenous expression of HrasG12V induces developmental defects and neoplasms with copy number imbalances of the oncogene  

UK PubMed Central (United Kingdom)

We developed mice with germline endogenous expression of oncogenic Hras to study effects on development and mechanisms of tumor initiation. They had high perinatal mortality, abnormal...Full Text Available

2009-05-12

194

Early Detection of Bronchial Lesions Using Lung Imaging Fluorescence Endoscope  

UK PubMed Central (United Kingdom)

The performance of the Lung Imaging Fluorescence Endoscope (LIFE) system was compared with conventional bronchoscopy in 158 patients: 68 patients with invasive cancer, 42 patients with abnormal sputum...Full Text Available

1999-01-01

195

Developmental abnormalities and epimutations associated with DNA hypomethylation mutations.  

UK PubMed Central (United Kingdom)

A number of aberrant morphological phenotypes were noted during propagation of the Arabidopsis thaliana DNA hypomethylation mutant, ddm1, by repeated self-pollination. Onset of a spectrum of morphological...Full Text Available

1996-10-29

196

DMSA scan nomograms for renal length and area: Related to patient age and to body weight, height or surface area  

International Nuclear Information System (INIS)

Aim: To create nomograms for renal size as measured from DMSA renal studies, and to test the nomograms for their ability to separate normal from abnormal kidneys. Method: Renal length was measured from posterior oblique views and renal area from posterior views. Results from 253 patients with bilateral normal kidneys were used to create nomograms for renal size relative to patient age, body height, weight or body surface area (BSA). The nomograms enclosed 95% of the normal kidneys, thus indicating the range for 95% confidence limits, and hence the specificity. Each nomogram was then tested against 46 hypertrophied kidneys and 46 damaged kidneys. Results: The results from nomograms of renal length and renal area, compared to age, body height, body weight and BSA are presented. For each nomogram, the range is presented as a fraction of the mean value, and the number of abnormal kidneys (hypertrophied or damaged) outside the normal range is ...

2002-09-01

197

Comparison of Different Measures of Urinary Protein Excretion for Prediction of Renal Events  

UK PubMed Central (United Kingdom)

There are many methods to screen for abnormal amounts of proteinuria to identify patients at risk for progression of renal disease, but which method best predicts renal risk is unknown. Here, we analyzed...Full Text Available

2010-08-01

198

Association Analysis of Nuclear Receptor Rev-erb Alpha Gene (NR1D1) and Japanese Methamphetamine Dependence  

UK PubMed Central (United Kingdom)

Several investigations suggested abnormalities in circadian rhythms are related to the pathophysiology of psychiatric disorders, including drug addiction. Recently, orphan nuclear receptor rev-erb alpha...Full Text Available

2011-03-01

199

Alcohol and the fetus in the west of Scotland.  

UK PubMed Central (United Kingdom)

Forty children with the fetal alcohol syndrome were identified in the west of Scotland. All were growth retarded and had abnormal facial features, and all those who were tested were found to have neurological...Full Text Available

1983-07-02

200

Activation of the alternate complement pathway in Staph. aureus infective endocarditis and its relationship to thrombocytopenia, coagulation abnormalities, and acute glomerulonephritis.  

UK PubMed Central (United Kingdom)

Twenty-four patients with infective endocarditis (IE) are described, fourteen with Staph. aureus and ten with other organisms. Despite the acute nature of the infection, ten of the fourteen with Staph....Full Text Available

1978-11-01

201

Abnormalities in the microsomal oxidases of the WHO standard reference strain of Musca domestica*  

UK PubMed Central (United Kingdom)

Observations made during biochemical and toxicological studies of the housefly, in which the WHO standard reference (SR) strain was used as a standard, indicated that this strain differs from other...Full Text Available

1975-01-01

202

Abnormal Brain Default-Mode Network Functional Connectivity in Drug Addicts  

UK PubMed Central (United Kingdom)

BackgroundThe default mode network (DMN) is a set of brain regions that exhibit synchronized low frequency oscillations at resting-state, and is believed to be relevant to attention...Full Text Available

203

A diagnostic survey of infants referred for chromosome analysis in the neonatal period.  

UK PubMed Central (United Kingdom)

Examination and assessment of 140 liveborn and stillborn infants referred within two weeks of birth for chromosome analysis showed that 48 had Down's syndrome, 12 other chromosome abnormalities, 17...Full Text Available

1980-10-18

204

A Cytogenetic Abnormality and Rare Coding Variants Identify ABCA13 as a Candidate Gene in Schizophrenia, Bipolar Disorder, and Depression  

UK PubMed Central (United Kingdom)

Schizophrenia and bipolar disorder are leading causes of morbidity across all populations, with heritability estimates of ∼80% indicating a substantial genetic component. Population genetics...Full Text Available

2009-12-11

207

Treatment of asymptomatic internal resorption of a maxillary premolar tooth in a military working dog.  

Science.gov (United States)

An asymptomatic pink discoloration of a maxillary right fourth premolar tooth was discovered during a routine oral examination on a 9 year-old Belgian Malinois dog. A radiolucent lesion was seen in the pulpal chamber on radiographic examination. The lesion had perforated the mesiobuccal root of the tooth. The primary differential diagnosis was idiopathic internal resorption. The tooth was treated by partial resection (removal of the mesiobuccal root and associated crown). A vital pulpotomy and amalgam restoration was performed on the remaining tooth structure. A follow-up 1 year later demonstrated a successful treatment outcome. The animal was asymptomatic and able to perform military duties. Clinical and radiographic signs of healing were evident and the tooth was functional. PMID:10518874

1998-12-01

208

Sequential scintimetry after femoral neck fracture. Methodologic aspects and prediction of healing complications  

Energy Technology Data Exchange (ETDEWEB)

Forty-five patients with recent cervical hip fractures were included in a prospective, clinical, radiographic and sequential scintimetric study. Striking changes in radionuclide uptake over the entire hip region on the fracture side were found during the first 5 postoperative months. Fractures that healed without complications showed the highest relative femoral head uptake at 1 week and a peak value at 6 weeks, followed by a gradual decline at the subsequent examinations. Fractures with complications (redisplacement, nonunion, or late segmental collapse) showed a lower initial uptake and a more gradual increase and only a slight tendency towards increased uptake after 3 months. The accuracy in predicting nonunion with scintimetric examination alone is high both at 1 and at 6 weeks, and the accuracy is almost equally high with combined scintimetric, radiographic, and clinical assessment 3-5 months postoperatively.

1987-01-01

209

Radiation-induced large intracranial vessel occlusive vasculopathy.  

Science.gov (United States)

Two patients who developed large intracranial vessel occlusion after standard radiation therapy for brain tumor are described. This form of vascular occlusion is usually seen in patients who have previously been treated by radiotherapy for intracranial tumor who then develop a relatively acute change in neurologic status. Histology of the lesion mimics accelerated focal arteriosclerosis. The clinical and radiographic manifestations of one case were highly atypical. The vasculopathy became evident shortly after termination of radiation therapy for a fourth ventricular ependymoma, and the angiographic picture stimulated a diffuse arteritis. The second patient was more typical, with clinical symptoms developing 12 years after radiation therapy for an oligodendroglioma. Occlusion of a proximal vessel that had been included in the radiation port was demonstrated radiographically and confirmed by pathologic examination. The clinical, angiographic, ...

1980-01-01

210

Radiation-induced large intracranial vessel occlusive vasculopathy  

Energy Technology Data Exchange (ETDEWEB)

Two patients who developed large intracranial vessel occlusion after standard radiation therapy for brain tumor are described. This form of vascular occlusion is usually seen in patients who have previously been treated by radiotherapy for intracranial tumor who then develop a relatively acute change in neurologic status. Histology of the lesion mimics accelerated focal arteriosclerosis. The clinical and radiographic manifestations of one case were highly atypical. The vasculopathy became evident shortly after termination of radiation therapy for a fourth ventricular ependymoma, and the angiographic picture stimulated a diffuse arteritis. The second patient was more typical, with clinical symptoms developing 12 years after radiation therapy for an oligodendroglioma. Occlusion of a proximal vessel that had been included in the radiation port was demonstrated radiographically and confirmed by pathologic examination. The clinical, angiographic, ...

1980-01-01

211

A method of stereotaxic localization adopted for conventional and digital radiography  

International Nuclear Information System (INIS)

A method for the determination of stereotaxic coordinates in radiography, e.g. angiography, pneumoencephalography or digital vascular radiography, is described. A special localization frame containing radiopaque structures and scales defines a diagnostic coordinate system. This frame is fixed to the X-ray-table prior to the radiographic procedure and two projections are obtained at arbitrary angles to each other. The focus-film distances do not have to be fixed. The target coordinates are then determined either by a simple graphical procedure or with the use of a digitizing x-y-table, by a computer. With the computer method the films are placed on the digitizing table and the target and a few reference points are marked using a cursor. From the relative positions the computer calculates the coordinates. With the special head fixation system, coordinates of structures visualized in radiographic examinations can be transferred to various ...

1986-01-01

212

Post-mortem fetal MRI: What do we learn from it?  

International Nuclear Information System (INIS)

Post-mortem magnetic resonance (MR) imaging is of increasing interest not only as an alternative to autopsy but as a research tool to aid the interpretation and diagnosis of in utero MR images. The information from the post-mortem MR has allowed the development of imaging sequences applicable to in utero imaging and neonatal imaging. It has established brain development during gestation and has provided data on this to which in utero MR can be compared. The detail available from the post-mortem images is such that brain development can be studied in a non-invasive manner, a permanent record on the normal and abnormal areas is available and a greater understanding of developmental abnormalities is possible.

2006-02-01

213

LPP combustion control for IC engine with abnormal combustion  

Energy Technology Data Exchange (ETDEWEB)

An LPP ignition timing control is described for an internal combustion engine including a combustion chamber, means effective to ignite a combustible charge within the combustion chamber and power output apparatus including a rotating crankshaft driven in response to the expansion of the combustible charge following the ignition thereof and having a predefined TDC rotational reference position, the engine being of the type having a normal combustion mode characterized by combustion pressure peaks compatible with closed loop LPP ignition timing control and an abnormal combustion mode which may not be so compatible.

1986-06-24

214

Clinical aspects of Marburg hemorrhagic fever  

British Library Electronic Table of Contents (United Kingdom)

Marburg virus belongs to the genus Marburgvirus in the family Filoviridae and causes a severe hemorrhagic fever, known as Marburg hemorrhagic fever (MHF), in both humans and nonhuman primates. Similar to the more widely known Ebola hemorrhagic fever, MHF is characterized by systemic viral replication, immunosuppression and abnormal inflammatory responses. These pathological features of the disease contribute to a number of systemic dysfunctions including hemorrhages, edema, coagulation abnormalities and, ultimately, multiorgan failure and shock, often resulting in death. A detailed understanding of the pathological processes that lead to this devastating disease remains elusive, a fact that contributes to the lack of licensed vaccines or effective therapeutics. This article will review the...

2011-01-01

215

Acute lymphoblastic leukemia with multiple cytogenetic abnormalities secondary to treatment of Ewing's sarcoma  

International Nuclear Information System (INIS)

We report the case of a 22-year-old man with Ewing's sarcoma who attained a complete remission (CR) after combination radiotherapy and chemotherapy. Secondary acute lymphoblastic leukemia with multiple cytogenetic abnormalities involving chromosome 5 and 7 developed 16 years later. The patient underwent induction chemotherapy and entered a CR. Peripheral blood stem cell transplantation from a matched sibling was performed successfully and he is in complete remission of both ALL and Ewing's sarcoma. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

1999-06-01

216

Response strategy and hierarchy of Wolsong 2, 3, and 4 nuclear power plant abnormal operating manuals  

International Nuclear Information System (INIS)

Wolsong 2, 3, and 4 are CANDU 6 pressurized heavy water nuclear power plants, each with a gross electrical output of 715 MW(e). The plants were constructed in the Republic of Korea during the 1990s. The three Wolsong units are based on the previous CANDU Wolsong Unit 1, declared in service in 1983. All four units are presently in commercial service. The Wolsong abnormal operating manuals were developed in a cooperative effort between Atomic Energy of Canada Limited, Korea Power Engineering Company staff, and Korea Electric Power Corporation. The role of Atomic Energy of Canada Limited in performing risk assessment studies and supporting CANDU stations for the preparation of emergency operating procedures has greatly benefited the Wolsong abnormal operating manual program. Korea Electric Power Corporation provided training and supervision, Korea Power Engineering Company Inc. prepared the documentation, and Korea Electric Power Corporation ...

217

Incidence of lesions as described by MRI in focal epilepsy of frontal and temporal onset; Inzidenz kernspintomographisch erfassbarer Laesionen bei der Abklaerung fokaler Epilepsien frontalen und temporalen Ursprunges  

Energy Technology Data Exchange (ETDEWEB)

Aim: Today, MRI is an integral part of the presurgical evaluation of patients suffering from partial epilepsy. These patients frequently show focal morphological abnormalities with potential epileptogenic character and surgical resection of these lesions is associated with superior postsurgical outcome as to seizure frequency. Apart from easily detectable defects, such as post-traumatic lesions or cerebral infarction, as wide variety of mainly small abnormalities can be detected using MRI. Methods: In this study, 484 patients suffering from partial epilepsy of temporal or frontal onset were evaluated for the incidence of different lesions in this population. Results: All lesions found were included without evaluating their potential epileptogenicity, which remains to be proven using other procedures (EEG, SPECT, PET, etc.). Involvement of the hippocampal formation was a major finding in temporal lobe epilepsy, which could ...

1997-09-01

218

AIDS and lung infection by Mycobacterium xenopi. Role of Computed Tomography; Sindrome da immunodeficienza acquisita e malattie polmonari da Mycobacterium xenopi. Ruolo della Tomografia Computerizzata  

Energy Technology Data Exchange (ETDEWEB)

Mycobacterium xenopi is one of the most common agents responsible for nontubercolar mycobacterial pulmonary disease on AIDS patients. These lesions have been studied with conventional radiography while CT has been used in patients with aspecific mycobacterioses or non-AIDS pulmonary conditions from Mycobacterium xenopi. 12 AIDS patients were examined. They had pulmonary lesions from Mycobacterium xenopi, patients age ranged 30 to 46 years. All patients had CD4 blood levels lower than 250 cells/mL and Mycobacterium xenopi in the sputum. All patients underwent a standard chest radiograph and a CT examination. CT images were evaluated by three radiologists independently and the definitive diagnosis was made in the presence of a fourth radiologist. Chest CT showed parenchymal consolidation in 66% of cases, associated with bilateral basal bands in 16% of cases. Consolidation was unilateral in 41% of cases and most frequently involved the right lower lobe. Bilateral ...

2000-06-01

219

Visualization of liquid metal two-phase flow by a real time neutron radiography system  

Energy Technology Data Exchange (ETDEWEB)

In order to understand the detail transient two-phase flow structure, more advanced two-phase flow instrumentation is required. One advanced technique for flow visualization is real-time neutron radiography. Reconstruction method of visualized radiographic image of liquid metal two-phase flow generated by the real-time neutron radiography system is proposed in this paper. Image processing techniques for noise reduction and image enhancement are discussed in detail. (author).

1995-11-01

220

Visualization of liquid metal two-phase flow by a real time neutron radiography system  

International Nuclear Information System (INIS)

In order to understand the detail transient two-phase flow structure, more advanced two-phase flow instrumentation is required. One advanced technique for flow visualization is real-time neutron radiography. Reconstruction method of visualized radiographic image of liquid metal two-phase flow generated by the real-time neutron radiography system is proposed in this paper. Image processing techniques for noise reduction and image enhancement are discussed in detail. (author).

1995-01-01

221

Screen-film-combinations for radiography - present and future spectrum of application  

Energy Technology Data Exchange (ETDEWEB)

From the numbers of radiographs of the different examinations and the total amount of radiological diagnostics in the GDR their possible modification by new imaging techniques is discussed under the aspects of costs and radiation burden. Film-screen-systems are of special importance, because they also will be most frequently used image recording system in future. The importance of their various properties and parameters, methods of determining these parameters as well as future developments are analyzed from the standpoint of practical requirements.

1985-01-01

222

Screen-film-combinations for radiography - present and future spectrum of application  

International Nuclear Information System (INIS)

From the numbers of radiographs of the different examinations and the total amount of radiological diagnostics in the GDR their possible modification by new imaging techniques is discussed under the aspects of costs and radiation burden. Film-screen-systems are of special importance, because they also will be most frequently used image recording system in future. The importance of their various properties and parameters, methods of determining these parameters as well as future developments are analyzed from the standpoint of practical requirements. (author).

223

Radiation exposure of the population of the GDR by X-ray diagnostics  

International Nuclear Information System (INIS)

The radiation burden of the people of the GDR in relation to biomedical radiography altogether as well as organ doses, gonad doses and genetically significant doses in detail are outlined. The concepts of radiation protection and standards of radiographic examination are demonstrated. Possibilities of influencing radiation exposure by scientifically based indication of X-ray examination, application of new and improvement of usual examination techniques are discussed with regard to quality assurance and control. Proposals concerning the reduction of radiation exposure of the GDR population are presented.

1986-01-01

224

Principium research of real-time neutron radiography in No. 300 reactor  

International Nuclear Information System (INIS)

The characteristics of real-time neutron radiography are described briefly in this paper, and the acquirement of neutron flux, the selection of convertor and the structure of the twilight imaging system and the image-sampling and image-processing system in SPRR-300 reactor are also analyzed detailedly. The experimental result of real-time neutron radiograph is too analyzed in this paper

2002-12-01

225

Iodixanol in cerebral computed tomography: a randomized, double-blind, phase-III, parallel study with iodixanol and iohexol  

Energy Technology Data Exchange (ETDEWEB)

Iodixanol is a new nonionic dimer, isotonic with blood at all clinically relevant concentrations. Iodixanol (270 mg I/ml) was compared in a double-blind, randomized, parallel-group, phase-III study to the monomeric nonionic iohexol (300 mg I/ml) for evaluation of safety, tolerability and radiographic efficacy during cerebral CT. One hundred adult patients scheduled to undergo contrast-enhanced cerebral CT were randomly allocated to receive either iodixanol or iohexol. All completed the trial. Safety was evaluated by recording discomfort and other adverse events, tolerance by assessing intensity and incidence of discomfort. Radiographic efficacy was assessed from the diagnostic information and the radiographic density. No serious adverse events occurred. One patient (2 %) in the iodixanol group and one patient (2 %) in the iohexol group experienced a transient reddening at the neck and lower neck-line, respectively. Both ...

1999-09-01

226

Esophageal perforation following bite of inner tube of automobile tyre: An unusual cause of barotrauma  

UK PubMed Central (United Kingdom)

An 8-year-old child presented with severe chest pain and respiratory distress after he accidentally bit an automobile tyre tube which burst into his mouth. The chest radiograph revealed left-sided pneumothorax....Full Text Available

2010-01-01

227

Eddy current imaging  

Energy Technology Data Exchange (ETDEWEB)

Image representations have gained wide acceptance in displaying data collected during optical, ultrasonic, radiographic, and thermographic inspections. Applying imaging techniques to eddy current testing is explored in this article. The authors show that flaw interpretation and characterization are made considerably simpler when images are used to visualize the impedance changes in eddy current probes.

1993-04-01

228

Demonstration of realtime radiography on pipeline girth welds: Final report  

Energy Technology Data Exchange (ETDEWEB)

Conventional radiography has been the accepted nondestructive testing (NDT) method used for many years to either ''accent'' or ''reject'' a field weld in the pipeline industry. However, conventional radiography requires the expense of film, developing chemicals, and manpower for film development. It also normally has a delay of 2 hours or more between when the weld was radiographed and when the radiographic film of the weld is available for interpretation. Over the last few years, a newer approach to performing radiographic testing, called ''realtime'' radiography, has been used in several different types of field inspection operations. The realtime radiography system forms the image with optical imaging in lieu of photographic film. Objectives of this project were: (Task 1) Integration of realtime x-ray system ...

1988-09-01

229

Reversal of brain metabolic abnormalities following treatment of AIDS dementia complex with 3'-azido-2',3'-dideoxythymidine (AZT, zidovudine): a PET-FDG study  

International Nuclear Information System (INIS)

Brain glucose metabolism was evaluated in four patients with acquired immunodeficiency syndrome (AIDS) dementia complex using ["1"8F]fluorodeoxyglucose (FDG) and positron emission tomography (PET) scans at the beginning of therapy with 3'-azido-2',3'-dideoxythymidine (AZT, zidovudine), and later in the course of therapy. In two patients, baseline, large focal cortical abnormalities of glucose utilization were reversed during the course of therapy. In the other two patients, the initial PET study did not reveal pronounced focal alterations, while the post-treatment scans showed markedly increased cortical glucose metabolism. The improved cortical glucose utilization was accompanied in all patients by immunologic and neurologic improvement. PET-FDG studies can detect cortical metabolic abnormalities associated with AIDS dementia complex, and may be used to monitor the metabolic improvement in response to AZT treatment.

230

MRI in pleural diseases  

International Nuclear Information System (INIS)

The MRI and CT appearances in 48 patients with histologically confirmed benign and malignant pleural abnormalities were compared retrospectively. Abnormal pleural changes were shown in 47 out of the 48 patients by high signal intensity of the pleura in T_2-weighted sequences and in contrast enhanced T_1-weighted sequences on MRI. CT showed abnormalities in 45 out of 48 patients. Delineation of pleural and pulmonary changes by CT was possible in 13 out of 23 cases, and pleural disease from effusions in 15 out of 28 cases. T_2-weighted MRI was successful in 14 out of 23 and 4 out of 28 cases, respectively. T_1-weighted images after contrast were successful in 20 out of 23 and 22 out of 28 cases, respectively. Indications of malignant pleural disease were the presence of mediastinal or circumferential involvement or involvement of the entire pleura, thickness of more than 10 mm and nodular changes. The most reliable sign of ...

231

Detection of abnormalities in febrile AIDS patients with In-111-labeled leukocyte and Ga-67 scintigraphy  

International Nuclear Information System (INIS)

Thirty-six patients with acquired immunodeficiency syndrome (AIDS), who were febrile but without localizing signs, underwent indium-111 leukocyte scintigraphy 24 hours after injection of labeled white blood cells (WBCs) and were restudied 48 hours after injection of gallium-67 citrate. Fifty-six abnormalities were identified as possible sources of the fever; 27 were confirmed with biopsy. Of these 27, 15 were identified only on In-111 WBC scans (including colitis, sinusitis, and focal bacterial pneumonia); six, only on Ga-67 scans (predominantly Pneumocystis carinii pneumonia and lymphadenopathy); and six, on both studies (predominantly pulmonary lesions). In-111 WBC scanning revealed 21 of 27 abnormalities (78%) and gallium scanning, 12 of 27 (44%). If only one scintigraphic study has been performed, particularly with Ga-67, a significant number of lesions would not have been detected. The authors believe radionuclide evaluation of the febrile ...

232

Clinical trial of NMR-CT, (4). Clinical evaluation of hybrid image  

Energy Technology Data Exchange (ETDEWEB)

In our evaluation we utilized the Asahi Mark-J NMR-CT system, with a resistive vertical quadrupolar electromagnet (0.1 Tesla) and a proton resonance frequency of 4.5 MHz. Our main imaging methods are the inversion-recovery or IR, saturation-recovery, or SR, and calculated T/sub 1/. Difference, or D images, constructed by subtracting the data of the IR signal from that of the SR signal, have also been obtained in some cases. The system allows averaging of raw data. Hybrid images were constructed from two or more images to obtain clear definition of areas of interest. By using the hybrid image, several tissues of different relaxation times can be shown in the same image. Application in our study of the newly developed hybrid image indicates its importance in the detection and diagnosis of lesion, especially the detection of the differentiation of an edematous lesion from a tumor, and also abnormal fluid collection such as the pleural effusion or ascites. We hope that ...

1985-01-01

233

CT appearances of unilateral cleft palate 20 years after bone graft surgery  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To describe CT appearances in patients with unilateral cleft lip and palate (CLP) 20 years after bone graft surgery. Material and Methods: Eighteen consecutive patients with unilateral CLP were examined. All patients had been treated with primary closure, both in infancy and early childhood, supplemented with bone grafting at the age of around 10 years. The CT examination of the upper jaw included a dental CT program. The CT appearances of the cleft side were compared with those of the untreated non-cleft side. Results: Abnormal CT appearances included skew nasal aperture (n=17), nasal septal deviation (n=17), low floor of nasal aperture (n=15) at or towards the cleft side, and deviation of anterior nasal spine towards the non-cleft side (n=18). The posterior part of the bone cleft was visible in all patients, and the dental arch was V-shaped in 8. Conclusion: Although adherence to the present treatment protocol is considered to give satisfactory ...

2002-11-01

234

CT appearances of unilateral cleft palate 20 years after bone graft surgery  

International Nuclear Information System (INIS)

Purpose: To describe CT appearances in patients with unilateral cleft lip and palate (CLP) 20 years after bone graft surgery. Material and Methods: Eighteen consecutive patients with unilateral CLP were examined. All patients had been treated with primary closure, both in infancy and early childhood, supplemented with bone grafting at the age of around 10 years. The CT examination of the upper jaw included a dental CT program. The CT appearances of the cleft side were compared with those of the untreated non-cleft side. Results: Abnormal CT appearances included skew nasal aperture (n=17), nasal septal deviation (n=17), low floor of nasal aperture (n=15) at or towards the cleft side, and deviation of anterior nasal spine towards the non-cleft side (n=18). The posterior part of the bone cleft was visible in all patients, and the dental arch was V-shaped in 8. Conclusion: Although adherence to the present treatment protocol is considered to give satisfactory ...

2002-11-01

235

Additional information from quantitative 24-hour sup 99m Tc-MDP bone scintigraphy in patients with prostatic carcinoma  

Energy Technology Data Exchange (ETDEWEB)

Quantitative bone scintigraphy was performed at 4 and 24 h after injection of {sup 99m}Tc-MDP. The lower thoracic and all the lumbar vertebrae were recorded in 37 patients with prostatic carcinoma before orchiectomy as well as two weeks, two and six months postoperatively. Fourteen patients had normal bone scintigrams. By means of the measured variation in the count rate between normal vertebrae, the criterion for a vertebra to be considered as abnormal was determined using the 4 h-uptake values. For patients with normal scintigrams the count rate at 24 h was below the 4 h level and the mean 24 h/4 h ratio was determined to be 0.85 {+-} 0.09 (1 SD). Normal vertebrae in patients with skeletal metastases had only slightly lower count rate values at 24 h than at 4 h. Abnormal vertebrae showed a higher count rate at 24 h, especially two weeks postoperatively, while a tendency towards lower values than at 4 h was seen after 6 months. If the 24 h/4 h ...

1991-01-01

236

Additional information from quantitative 24-hour "9"9"mTc-MDP bone scintigraphy in patients with prostatic carcinoma  

International Nuclear Information System (INIS)

Quantitative bone scintigraphy was performed at 4 and 24 h after injection of "9"9"mTc-MDP. The lower thoracic and all the lumbar vertebrae were recorded in 37 patients with prostatic carcinoma before orchiectomy as well as two weeks, two and six months postoperatively. Fourteen patients had normal bone scintigrams. By means of the measured variation in the count rate between normal vertebrae, the criterion for a vertebra to be considered as abnormal was determined using the 4 h-uptake values. For patients with normal scintigrams the count rate at 24 h was below the 4 h level and the mean 24 h/4 h ratio was determined to be 0.85 #+-# 0.09 (1 SD). Normal vertebrae in patients with skeletal metastases had only slightly lower count rate values at 24 h than at 4 h. Abnormal vertebrae showed a higher count rate at 24 h, especially two weeks postoperatively, while a tendency towards lower values than at 4 h was seen after 6 months. If the 24 h/4 h ...

237

A mathematical/physiological model of parathyroid hormone secretion in response to blood-ionized calcium lowering in vivo.  

DEFF Research Database (Denmark)

The aim of the present study was to test a mathematical model of the biochemical processes in the parathyroid glands responsible for the secretion of parathyroid hormone resulting from extracellular calcium reduction. A double exponential curve described the parathyroid hormone secretion induced by rapid lowering of blood-ionized calcium in humans with normal as well as abnormal parathyroid tissue. Our data show that it was possible to establish a simple mathematical model of the parathyroid hormone response to blood-ionized calcium lowering, sufficient to fit experimental data obtained from patients with abnormal and normal parathyroid tissue. The fitted parameters showed no significant differences between patients with insulin-dependent diabetes mellitus and controls. In primary hyperparathyroidism, the parathyroid hormone production and steady-state transport across the cell membrane were increased, probably due to the larger amount of ...

1997-01-01

238

[75Se]Selenomethionine scanning for parathyroid localization should be abandoned  

International Nuclear Information System (INIS)

Image subtraction techniques, in conjunction with [75Se]selenomethionine (75Se) scintigraphy, have recently been suggested to be a potentially valuable tool for localization of parathyroid abnormalities. With use of these techniques, we prospectively studied 15 patients scheduled for parathyroid operations. Postoperatively, all were normocalcemic. Anterior scintiscans of the neck were divided into quadrants, and regions of enhanced uptake were assigned to one or more quadrants. On this basis, by chance alone a minimum of 25% of single-gland enlargements would be assigned to the correct quadrant of the neck. We found that by use of 75Se scanning only 8 of 22 abnormal glands (36%) were assigned to the quadrant of the neck in which they were found intraoperatively. In no case was a clearly visualized focus of parathyroid activity encountered. These results do not justify the continued use of 75Se scintigraphy with or without image subtraction in ...

239

Cytogenetic polyclonality of breast carcinomas: Association with Clinico-Pathological Characteristics and Outcome  

British Library Electronic Table of Contents (United Kingdom)

Abstract Routinely used prognostic factors fail to predict clinical outcome in a significant proportion of breast cancer patients, implying that they can not detect some important biological characteristics. Chromosomal changes have been described in breast carcinomas for many years but their significance is not clear. We compared chromosomal changes with clinico-pathological characteristics and clinical outcome in 203 breast cancer patients with a follow-up of 9-18 years. Combining data from classical cytogenetics and flow cytometry revealed chromosomal abnormalities in 142 cases (70%). Of these, 51 (35.9%) contained two or more cytogenetically abnormal clones. Polyclonality was significantly associated with poor breast-cancer-specific survival (P = 0.03) within 5 years, independent of tu...

2011-01-01

240

Control rod drives  

International Nuclear Information System (INIS)

Purpose: To secure the reactor operation safety by the provision of a fluid pressure detecting section for control rod driving fluid and a control rod interlock at the midway of the flow pass for supplying driving fluid to the control rod drives. Constitution: Between a driving line and a direction control valve are provided a pressure detecting portion, an alarm generating device, and a control rod inhibition interlock. The driving fluid from a driving fluid source is discharged by way of a pump and a manual valve into the reactor in which the control rods and reactor fuels are contained. In addition, when the direction control valve is switched and the control rods are inserted and extracted by the control rod drives, the pressure in the driving line is always detected by the pressure detection section, whereby if abnormal pressure is resulted, the alarm generating device is actuated to warn the abnormality and the control rod inhibition ...

241

Fuji computed radiography (FCR) for the diagnosis of spinal disorders  

International Nuclear Information System (INIS)

Since April, 1985, we have, in co-operation with the Fuji Film Co., Ltd., used Fuji Computed Radiography (FCR) in the diagnosis of spinal disorders. FCR is a new computed radiographic system which uses an energy-storage phosphorus panel called an ''Imaging Plate'' as an image sensor. The ''Imaging Plate'' can be used to obtain radiographs in exactly the same way as the screen-film combination used in conventional radiography; X-rays are exposed on the ''Imaging Plate'' instead of X-ray film in the conventional fashion, and then the ''Imaging Plate'' is calculated. The processed digital data from the scans is transformed into a picture by means of digital-to-analogue conversion. The pictures are always clear and beautiful. Plain films of the spine taken by FCR are even clearer, even in the cervicothoracic region, where it is usually difficult to obtain clear cervicothoracic films in conventional radiography. We can obtain much precise ...

1987-01-01

242

Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures  

Energy Technology Data Exchange (ETDEWEB)

AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the performance of caesium ...

2002-04-01

243

Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures  

International Nuclear Information System (INIS)

AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the performance of caesium ...

2002-04-01

244

Diagnostic possibilities following implantation of carbon-fibre-reinforced plastic (CFRP) total hip arthroplasty  

International Nuclear Information System (INIS)

Introduction: There are many problems in the radiological diagnosis of aseptic loosening in total hip arthroplasty. Computed tomography (CT) and magnetic resonance tomography (MRT) are not usable for metallic implants (stainless steel, cobalt alloy, titanium alloy). Material and Methods: From April 1993 to December 1993 15 CFRP non-cemented hip prostheses have been implanted. In a prospective clinical study plane radiographs, CT and MRT have been analysed. Results: Three stems were revised (1 femoral fracture, 1 severe thigh pain, 1 aseptic loosening). CFRP are not visible in plane radiographs. There was a complete (two-third of the cases) or nearly complete (one-third of the cases) small sclerotic interface between the prosthesis and the bone, these were apparent in CT and MRT in stable implant cases and did not have any clinical correlations. Discussion: The small sclerotic interface is quite different in comparison to so called 'Reactive ...

245

Visualization of right atrial appendix by Thallium-201 myocardial scintigraphy: concise communication  

Energy Technology Data Exchange (ETDEWEB)

The atrial myocardium has been barely visible with thallium-201 myocardial scintigraphy. This is probably related to the difference in size, distance from anterior chest wall, and small coronary blood flow of the atrium, compared with the ventricle. We have encountered eight cases of visualization of the right atrial appendix (RAA). The RAA was identified from multiple projections in all cases and sometimes confirmed by radionuclide angiocardiography. Evidence derived from ECG, chest radiographs, and cardiac catheterization, indicated that the most important factor in the visualization might be the displacement of the RAA to a more anterior position.

1980-10-01

246

Radiology of facial injury  

Energy Technology Data Exchange (ETDEWEB)

The authors present a guide to the imaging of facial fractures. It is illustrated with conventional radiographs and computed tomograms; the magnetic resonance images primarily suggest the potential applications of this technique. This book provides a source of imaging information on facial trauma. A section on pertinent anatomy is followed by a systematic discussion of the common isolated and complex facial fractures. Perspectives are offered on some commonly seen but infrequently described relationships, such as the tripod-LeFort II association. Consideration is also given to related soft-tissue injuries. The book includes a brief chapter on the type and utility of supplementary imaging studies in the evaluation of those intracranial injuries that may occur concurrently.

1988-01-01

247

Radiological protection. Textbook for radiographers and reference book for radiological safety officers  

International Nuclear Information System (INIS)

The textbook is primarily intended for radiologic staff and radiologic safety officers and gives information on the current regulatory provisions of the German X-ray Ordinance, applications of X-rays, quality assurance, organisational aspects of film processing and quality requirements of X-rays. An annex lists the guidelines of the Bundesaerztekammer (German National Chamber of Physicians) relating to quality assurance aspects, and further useful information on commercially available film-screen systems, the various associations of physicians in Germany, and requirements and performance of radiation surveys. (vhe).

248

Radiodiagnosis of Ewing's sarcoma of the rib in children  

International Nuclear Information System (INIS)

The results of the examination of 23 children with Ewing's sarcoma of the rib were analyzed: panoramic chest X-rays in 4 projections, spot radiographs of the robs, superexposed pictures, laterograms, urography, angiography, computerized tomography, and scanning of the skeleton. Causes of diagnostic errors made at the first consultation by a physician, were identified. Peculiarities of X-ray signs of tumors of this site in children were studied. Diagnostic difficulties in tumors complicated by pleurisy and in tumors of small sizes with extrapleural growth were shown. Inclusions in the extraoseous tumor component were noted in 8.7% of the cases.

249

Radiation-protection survey guide: fixed radiographic unit. Final report, June 1980-April 1985  

Energy Technology Data Exchange (ETDEWEB)

Prior to routine use, all newly installed x-ray machines must have a radiation-protection survey by a qualified expert. The survey is an evaluation of existing or potential radiation hazards associated with the use of diagnostic x-ray equipment under specific conditions. Such evaluation includes the measurement of exposure levels in the environment as well as environmental levels arising from operation of the equipment. The survey also includes an evaluation of the safety characteristics of the x-ray unit.

1985-05-01

250

Patterns of gallium-67 scintigraphy in patients with acquired immunodeficiency syndrome and the AIDS related complex  

Energy Technology Data Exchange (ETDEWEB)

Thirty-two patients with AIDS related complex (ARC) or acquired immunodeficiency syndrome (AIDS) underwent /sup 67/Ga scans as part of their evaluation. Three patterns of /sup 67/Ga biodistribution were found: lymph node uptake alone; diffuse pulmonary uptake; normal scan. Gallium-67 scans were useful in identifying clinically occult Pneumocystis carinii pneumonia in seven of 15 patients with ARC who were asymptomatic and had normal chest radiographs. Gallium scans are a useful ancillary procedure in the evaluation of patients with ARC or AIDS.

1987-07-01

251

Organ doses to atomic bomb survivors during photofluorography, fluoroscopy and computer tomography  

Energy Technology Data Exchange (ETDEWEB)

Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).

1991-08-01

252

Organ doses to atomic bomb survivors during photofluorography, fluoroscopy and computer tomography  

International Nuclear Information System (INIS)

Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).

1991-01-01

253

Neutron radiography with the cyclotron, 5  

International Nuclear Information System (INIS)

Reliable facility of cyclotron-based real time neutron radiography system has been developed and applied to some industrial components. The equipment for neutron fluoroscopy is based on a sub-compact cyclotron and a LiF/ZnS (Ag) fluorescent screen viewed by a silicon intensifier target TV camera. The real time image is monitored on a CRT, recorded with a standard video recorder and processed by a digital image processor. The effectiveness of our real time neutron radiograph has been demonstrated to be applicable to not only the dynamic observation but also the magnifying and stereoscopic observation of fluoroscopic images. (author).

1987-01-01

254

Lung cancer screening program using annual chest radiographs with computed radiography (FCR)  

Energy Technology Data Exchange (ETDEWEB)

In the Wajima lung cancer screening program conducted under the auspices of Kanazawa University Hospital, Fuji Computed Radiography (FCR) was utilized in a new chest radiography trial. The results of the screening program are that the necessity of repeat examinations due to poor image quality are less common and the method enables detection of small pulmonary nodular shadows which are possibly candidates for surgery. Oblique chest X-ray with FCR is remarkably effective for the detection and the identification of small lesions. However, the disadvantage of slow processing and high cost must be fully satisfied if FCR is to become a new imaging modality for mass screening.

1987-08-01

255

Lung cancer screening program using annual chest radiographs with computed radiography (FCR)  

International Nuclear Information System (INIS)

In the Wajima lung cancer screening program conducted under the auspices of Kanazawa University Hospital, Fuji Computed Radiography (FCR) was utilized in a new chest radiography trial. The results of the screening program are that the necessity of repeat examinations due to poor image quality are less common and the method enables detection of small pulmonary nodular shadows which are possibly candidates for surgery. Oblique chest X-ray with FCR is remarkably effective for the detection and the identification of small lesions. However, the disadvantage of slow processing and high cost must be fully satisfied if FCR is to become a new imaging modality for mass screening. (author).

1987-01-01

256

International trends in radiation protection  

International Nuclear Information System (INIS)

The great uranium debate throughout the industrialised world has intensified awareness of the biological hazards from ionizing radiation. It is therefore appropriate to use this awareness to draw attention to medical X-Radiation which today represents the most significant risk to future generations. There is ample legislation to control proliferation of nuclear development but in diagnostic radiology proliferation is unlimited; most international surveys indicate an unchecked annual growth rate of 15%. The article looks at risk hypotheses, dose measurements and the responsibilities of practising radiographers, and also reviews the international situation as reported at the 1977 world congress of radiation protection.

257

Impingement fracture of the anteromedial tibial margin: a radiographic sign of combined posterolateral complex and posterior cruciate ligament disruption  

Energy Technology Data Exchange (ETDEWEB)

Marginal fractures of the tibial plateau are associated with a high incidence of soft tissue injuries to the stabilising structures of the knee joint. Injuries to the anterior cruciate ligament are associated with the Segond fracture and impingement fractures of the posteromedial tibial plateau. Recognition of these fractures aids diagnosis of these injuries. Marginal fractures of the tibial plateau associated with posterior cruciate ligament injuries are less common, though recently a ''reverse'' Segond fracture has been recognised. We describe a fracture of the anteromedial tibial plateau associated with complete disruption of the posterior cruciate ligament and posterolateral complex. (orig.)

2001-02-01

258

Imaging Automation and Volume Tomographic Visualization at Texas Neutron Imaging Facility  

Energy Technology Data Exchange (ETDEWEB)

A thermal neutron imaging facility for real-time neutron radiography and computed tomography has been developed at the University of Texas reactor. The facility produced good-quality radiographs and two-dimensional tomograms. Further developments have been recently accomplished. A computer software has been developed to automate and expedite the data acquisition and reconstruction processes. Volume tomographic visualization using Interactive Data Language (IDL) software has been demonstrated and will be further developed. Volume tomography provides the additional flexibility of producing slices of the object using software and thus avoids redoing the measurements.

1999-11-14

259

Hard X-ray phase imaging and tomography using a grating interferometer  

International Nuclear Information System (INIS)

An interferometric technique for hard X-rays is presented. It is based on two transmission gratings and a phase-stepping technique, and it provides separate radiographs of the phase and absorption profiles of bulk samples. Tomographic reconstruction yields quantitative three-dimensional maps of the X-ray refractive index and of the attenuation coefficient, with a spatial resolution down to a few microns. The method is mechanically robust, it requires little monochromaticity, and can be scaled up to large fields of view. These are important prerequisites for use with laboratory X-ray sources. Numerous applications ranging from wave front sensing to medical radiography are presently under investigation.

2007-07-01

260

FCR (Fuji Computed Radiography) in neurosurgery  

Energy Technology Data Exchange (ETDEWEB)

As part of the evolution of computer technology, Fuji Computed Radiography (FCR) has been developed as a new system for radiographical diagnosis. In this system, the X-ray energy is stored on the imaging plate and then converted into digital signals utilizing scanning laser-stimulated luminence. After proper image processing, it offers much more improved information for diagnosis than the conventional film system does. Since April, 1986, we have principally used FCR (System 101) for neurosurgical practice. In this article, we present our recent experience and evaluate its usefulness.

1988-08-01

261

FCR (Fuji Computed Radiography) in neurosurgery  

International Nuclear Information System (INIS)

As part of the evolution of computer technology, Fuji Computed Radiography (FCR) has been developed as a new system for radiographical diagnosis. In this system, the X-ray energy is stored on the imaging plate and then converted into digital signals utilizing scanning laser-stimulated luminence. After proper image processing, it offers much more improved information for diagnosis than the conventional film system does. Since April, 1986, we have principally used FCR (System 101) for neurosurgical practice. In this article, we present our recent experience and evaluate its usefulness. (author).

1988-01-01

262

Estimation of armature condition in concrete with gamma-absorption method  

International Nuclear Information System (INIS)

Bases of the algorithm for assessing the reinforcement status in reinforced concrete products by gamma-absorption method are presented. Analytical equations are obtained for estimation of error of the parameter characterizing the degree of reinforcement destruction. It is recommended to use high-energy Bremsstrahlung sources-betatrons of 4-10 MeV maximum energy for testing products of 500-600 mm thick. Linear radiation attenuation factor (LAF) of concrete in estimated equation is replaced by effective LAF of concrete, and LAF of reinforcement and corrosion materials - by differential LAF. Corresponding LAF of nonevident form in the algorithm is assessed by the results of processing of direct-shadow radiographs of defectometers

263

Combined Modality Treatment for Prostate Cancer With Dynamic Adaptive Radiation Therapy Using Four-Dimensional Image-Guided Intensity-Modulated Radiation Therapy and Brachytherapy  

British Library Electronic Table of Contents (United Kingdom)

Prostate cancer can be successfully treated using dynamic adaptive external beam radiation techniques along with interstitial brachytherapy to deliver curative therapies with low urinary, rectal and erectile function morbidity. Through the use of sophisticated, state-of-the art radiographic imaging for staging and treatment planning, a precise, individual design for treatment is accomplished. Symptom management and patient education are of paramount importance and are integrated throughout the treatment process.

2009-01-01

264

Characterization of jet breakup mechanisms observed from simulant experiments of molten fuel penetrating coolant  

Science.gov (United States)

The goal of this research program has been to add to our understanding of the breakup of molten fuel jets penetrating reactor coolant. Easily handled working fluids are used to simulate fuel jet breakup, so that detailed observations may be obtained from a relatively large number of experiments. The tools used for observing this behavior are high speed notion picture photography, Flash X-radiography, and X-ray cine. Jet breakup lengths are determined from motion pictures; the mechanisms by which the jets are fragmented may be inferred from radiographs.

1992-01-01

265

Avascular necrosis associated with nailing of femoral neck fracture  

Energy Technology Data Exchange (ETDEWEB)

Two patients with femoral neck fractures, one displaced and one undisplaced, are presented. Preoperative intravital staining with tetracycline and Tc-MDP scintimetry both showed intact femoral head circulation while Tc-MDP-scintimetry 1 week after operation showed pronounced circulatory deficiency. Sr/sup 85/-scintimetry performed at the same time was inconclusive. Segmental collapse was observed radiographically, 8 and 12 months postoperatively. The major vascular injury resulting in avascularity most probably occured during the procedure of osteosynthesis, and Tc-MDP-scintimetry was found suitable for early postoperative recognition of avascular necrosis in both fractures.

1983-01-01

266

Avascular necrosis associated with nailing of femoral neck fracture  

International Nuclear Information System (INIS)

Two patients with femoral neck fractures, one displaced and one undisplaced, are presented. Preoperative intravital staining with tetracycline and Tc-MDP scintimetry both showed intact femoral head circulation while Tc-MDP-scintimetry 1 week after operation showed pronounced circulatory deficiency. SR"8"5-scintimetry performed at the same time was inconclusive. Segmental collapse was observed radiographically, 8 and 12 months postoperatively. The major vascular injury resulting in avascularity most probably occured during the procedure of osteosynthesis, and Tc-MDP-scintimetry was found suitable for early postoperative recognition of avascular necrosis in both fractures. (author).

267

Application of the tracer technique to study on casting solidification  

International Nuclear Information System (INIS)

The results and techniques of radiographic study on solidification of iron and steel mould castings are described. The study was made to determine the causes of the mold castings defects. The liquid metal is either labelled in the ladle, or relabelled inside the mould in present time intervals. In the former case, the radioactive phosphorus is segregated in the last-solidifying casting locations, and in the latter, the radioactive phosphorous is distributed along the solid-liquid interface at the time of the next addition in turn. The solidification process parameters may be arrived at by the autoradiograms taken in the pipe-sensitive casting sections. Using these data it is possible to proceed to the proper modifications in the steel casting process.

268

The effect of patient shield position on gonad dose during lumbar spine radiography  

Energy Technology Data Exchange (ETDEWEB)

Background: In an effort to standardise radiological practices in the Republic of Ireland, current legislation states that 'written protocols for every type of standard radiological practice shall be established'. In order to fulfil this requirement the Irish Medical Council recommends the protocols issued by the Commission of European Communitees (CEC) for adoption in the country. Whilst this document does provide good guidance with regard to various radiographic factors, patient shielding instructions are notably ambiguous. The aim of this study was to remove some of this ambiguity by defining the optimal method of positioning patient shielding in antero-posterior (AP) and lateral lumbar spine radiographic examinations. These projections were chosen on the basis of their area of coverage being in close to and in some cases including the reproductive organs. They also represent the highest source of collective population dose ...

2010-05-15

269

The effect of patient shield position on gonad dose during lumbar spine radiography  

International Nuclear Information System (INIS)

Background: In an effort to standardise radiological practices in the Republic of Ireland, current legislation states that 'written protocols for every type of standard radiological practice shall be established'. In order to fulfil this requirement the Irish Medical Council recommends the protocols issued by the Commission of European Communitees (CEC) for adoption in the country. Whilst this document does provide good guidance with regard to various radiographic factors, patient shielding instructions are notably ambiguous. The aim of this study was to remove some of this ambiguity by defining the optimal method of positioning patient shielding in antero-posterior (AP) and lateral lumbar spine radiographic examinations. These projections were chosen on the basis of their area of coverage being in close to and in some cases including the reproductive organs. They also represent the highest source of collective population dose of any ...

2010-05-01

270

Stochastic risk estimation from medical x-ray diagnostic examinations, 2  

International Nuclear Information System (INIS)

The risks of genetic, leukemia and malignant diseases from medical X-ray diagnostic examinations were estimated using the frequency of radiographic and fluoroscopic exposures per diagnostic examination, child expectancy, leukemia and malignancy significant factors, and using a weighting factor determined on the basis of data concerning the cancer mortality among atomic bomb survivors in Nagasaki and of a recommendation of International Commission of Radiological Protection. The organ or tissue doses with respect to the stochastic risks were determined with ionization chambers and thermoluminescent dosimeters placed at the positions of the organs or tissues in a RANDO woman phantom which was exposed to diagnostic X-rays according to technical factors of typical radiographic and fluoroscopic examinations obtained from a nationwide survey. The resultant risks by age-group and type of radiographic and fluoroscopic examination ...

1981-01-01

271

Radiation exposure of children in pediatric radiology. Pt. 5. Organ doses in chest radiography; Zur Strahlenexposition von Kindern in der paediatrischen Radiologie. T. 5. Organdosen bei der Roentgenuntersuchung des Thorax  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Reconstruction of organ doses of selected organs and tissues from radiographic settings and exposure data collected during chest X-ray examinations of children of various age groups performed in Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007. Materials and Method: The dosimetric data of all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 119 150 chest radiographs of all age groups. Reconstruction of organ doses in 40 organs and tissues in X-ray examinations of the chest was performed based on the conversion factor concept. Results: The radiation exposure of organs in projection radiography is determined by the exact site of the organs relative to the edges of ...

2009-05-15

272

Transgenerational Effects of Di (2-Ethylhexyl) Phthalate in the Male CRL:CD(SD) Rat: Added Value of Assessing Multiple Offspring per Litter  

UK PubMed Central (United Kingdom)

In the rat, some phthalates alter sexual differentiation at relatively low dosage levels by altering fetal Leydig cell development and hormone synthesis, thereby inducing abnormalities of the testis,...Full Text Available

2009-08-01

273

Transforming growth factor-? signaling mediates hypoxia-induced pulmonary arterial remodeling and inhibition of alveolar development in newborn mouse lung  

UK PubMed Central (United Kingdom)

Hypoxia causes abnormal neonatal pulmonary artery remodeling (PAR) and inhibition of alveolar development (IAD). Transforming growth factor (TGF)-β is an important regulator of lung development...Full Text Available

2008-07-01

274

The k43 gene, required for chorion gene amplification and diploid cell chromosome replication, encodes the Drosophila homolog of yeast origin recognition complex subunit 2  

UK PubMed Central (United Kingdom)

Lethal alleles of the Drosophila k43 gene result in small or missing imaginal discs, greatly reduced mitotic index, and fragmented and abnormally condensed chromosomes. A female-sterile...Full Text Available

1997-04-15

275

Problems and solutions of the IFSMTF power and switch system  

Energy Technology Data Exchange (ETDEWEB)

Solutions have been found for the problems encountered with the coil power and switching systems of the International Fusion Superconducting Magnet Test Facility (IFSMTF). The coil power system provides the filtered dc sources (+- 12 V dc; 25,000 A) for charging and discharging the coils of the IFSMTF experiment. The switching system provides the means of transferring the coil current into a dump resistor when a rapid discharge of a coil is required due to a coil failure (quench) or other system abnormalities.

1985-01-01

276

Normal and abnormal neuronal migration during brain development  

International Nuclear Information System (INIS)

Conceptual and factual advances in understanding neuronal migration in the past two decades have provided new insight into the pathogenesis of brain malformations at the cellular, molecular, and functional levels. Some of these results may have direct implications in understanding the consequences of ionizing radiation on the fetal central nervous system in utero. (orig.).

277

Lyme myocarditis diagnosed by indium-111-antimyosin antibody scintigraphy  

Energy Technology Data Exchange (ETDEWEB)

We report a new case of Lyme disease with cardiac manifestations, which has been possible to follow during the long period of 12 years. We have detected the usual ECG abnormalities, and concentric hypertrophic myocardiopathy, by echocardiography. The acute myocarditis was demonstrated by /sup 111/In-antimyosin scintigraphy, which showed global myocardial uptake of the tracer, constituting the first report, to our knowledge, of Lyme myocarditis diagnosed by this method.

1989-06-01

278

Improved detection of myocardial infarction with technetium-99m stannous pyrophosphate and serum MB creatine phosphokinase  

International Nuclear Information System (INIS)

The relative sensitivity and combined value of myocardial technetium-99m stannous pyrophosphate imaging and determinations of serum MB creatine phosphokinase (the ''myocardial'' CPK isoenzyme) in detecting acute myocardial infarction were evaluated in 41 patients with suspected infarction and 23 patients recovering from cardiac surgery. In the patients with suspected infarction, myocardial infarction was confirmed in 25 and was consistently associated with increased serum MB CPK. Abnormal radionuclide images were obtained in 23 of 25 patients (92%)) with definite myocardial infarction and in 2 of 16 patients without confirmed infarction. Although the localization of infarction by imaging correlated well with the localization by electrocardiogram, infarct size estimated by imaging did not correlate well with estimates based on peak total serum CPK activity or serial changes in CPK activity. Serum MB CPK activity increased after cardiac surgery in 6 patients ...

279

Hypothyroidism in Noninterferon Treated-HCV Infected Individuals Is Associated with Abnormalities in the Regulation of Th17 Cells  

UK PubMed Central (United Kingdom)

HCV-Ag-specific TH17 cells secrete IL17, a cytokine involved in autoimmune diseases and regulated by IL10 and TGF-b. 5–12% of patients with chronic HCV infection have hypothyroidism. We evaluated...Full Text Available

2010-01-01

280

Hydraulic device for control rod drive mechanisms  

International Nuclear Information System (INIS)

Purpose: To improve the reliability of control rod drive mechanisms for use in BWR type reactors by preventing erroneous insertion of control rods caused by the increase in the coolant pressure. Constitution: A pressure-releaf valve mechanism is provided which opens its valve when a detected difference between the pressure of the coolants flowing through coolant pipeways and the reactor pressure exceeds a predetermined pressure difference. If the coolant pressure increases abnormally, coolants in the coolant pipeway are released to lower the pressure. (Aizawa, K.).

1981-07-31

281

Evaluation of peripheral vascular disease by intravenous digital subtraction angiography with the Fuji computed radiography (FCR) system  

Energy Technology Data Exchange (ETDEWEB)

Intravenous digital subtraction angiography using Fuji computed radiography system (FCR-DSA) was used to evaluate 57 preoperative patients with clinical manifestations of peripheral vascular disease of lower extremity. With its high contrast resolution and good special resolution, image of FCR-DSA could offer optimal information of vascular abnormality in lower extremity distal to midfoot for the diagnosis and the choice of management.

1987-03-01

282

Evaluation of peripheral vascular disease by intravenous digital subtraction angiography with the Fuji computed radiography (FCR) system  

International Nuclear Information System (INIS)

Intravenous digital subtraction angiography using Fuji computed radiography system (FCR-DSA) was used to evaluate 57 preoperative patients with clinical manifestations of peripheral vascular disease of lower extremity. With its high contrast resolution and good special resolution, image of FCR-DSA could offer optimal information of vascular abnormality in lower extremity distal to midfoot for the diagnosis and the choice of management. (orig.).

1987-01-01

283

Deficiency in trefoil factor 1 (TFF1) increases tumorigenicity of human breast cancer cells and mammary tumor development in TFF1-knockout mice  

UK PubMed Central (United Kingdom)

Although trefoil factor 1 (TFF1; previously named pS2) is abnormally expressed in about 50% of human breast tumors, its physiopathological role in this disease has been poorly studied. Moreover,...Full Text Available

2011-07-21

284

Criticality safety review of FFTF interim decay storage tank  

Science.gov (United States)

The Interim Decay Storage tank (IDS) will be located in a concrete cell in the FFTF reactor building. The tank will have capacity to store 112 driver fuel assemblies and 10 test assemblies in sodium. A criticality safety analysis for the design of the IDS tank was performed. From the analysis, it is concluded that under normal operating conditions and minor abnormal conditions that might shift the fuel, the IDS tank will remain adequately subcritical. (auth)

1975-10-01

285

Computer tomographic ventriculography  

Energy Technology Data Exchange (ETDEWEB)

A method for elucidating complex abnormalities of CSF circulation by using a positive contrast medium (metrizamide) and computer tomography is described. The technique for the method, the results and their clinical significance is demonstrated. The value of this method is compared with traditional ventriculography and with computer tomography without the use of contrast medium. It is shown that the technique represents an important extension of the scope of computer tomography.

1982-04-01

286

Computed tomography of the urinary bladder. Clinical application of the olive oil-filled method  

Energy Technology Data Exchange (ETDEWEB)

Out of one hundred cases of the urinary bladder abnormalities examined by this method, CT staging and pathological correlations were investigated in 61 cases of the urinary bladder neoplasms. Accuracy of CT staging was 87% in this series with possible exception of 6 cases involving the bladder base and dome. CT scan using this method is the most reliable procedure to determine the treatment modalities of the urinary bladder tumors.

1982-01-01

287

Brain and bone scans in primary Ewing's sarcoma of the petrous bone: case report  

International Nuclear Information System (INIS)

The authors present a case in which primary Ewing's sarcoma of the right petrous pyramid in a 9-year-old girl showed no uptake on a /sup 99m/Tc-pertechnetate nuclide angiogram. Intense uptake was present on a /sup 99m/Tc-polyphosphate bone scan, but a static brain scan was only minimally abnormal. The diagnosis and treatment of Ewing's sarcoma are reviewed.

288

Atlas of nuclear medicine imaging  

Energy Technology Data Exchange (ETDEWEB)

An exhaustive compendium of normal and abnormal imaging is presented. The following systems and procedures are illustrated by over 2800 captioned illustrations: liver, spleen, and hepatobiliary imaging; perfusion and ventilation lung imaging; thyroid imaging; salivary gland imaging; bone imaging; brain imaging; radionuclide cisternography; blood flow studies; gallium imaging; nuclear cardiology; and renal imaging. Not included in the atlas are adrenal imaging procedures and emission computed tomography. (ERB)

1981-01-01

289

An activated renin-angiotensin system maintains normal blood pressure in aryl hydrocarbon receptor heterozygous mice but not in null mice  

UK PubMed Central (United Kingdom)

It has been postulated that fetal vascular abnormalities in aryl hydrocarbon receptor null (ahr−/−) mice may alter cardiovascular homeostasis in adulthood....Full Text Available

2010-07-15

290

Abnormalities of polymorphonuclear leukocyte function associated with a heritable deficiency of high molecular weight surface glycoproteins (GP138): common relationship to diminished cell adherence.  

UK PubMed Central (United Kingdom)

Investigations of polymorphonuclear leukocyte (PMN) function were performed in a 5-yr-old white female with delayed umbilical cord separation, impaired pus formation, and a severe defect of PMN chemotaxis....Full Text Available

1984-08-01

292

Combining adjusted and unadjusted findings in mixed research synthesis  

British Library Electronic Table of Contents (United Kingdom)

Abstract Rationale, aims and objectives- Finding ways to incorporate disparate types of evidence into research syntheses has the potential to build a better evidence base for clinical practice and policy. Yet conducting such mixed research synthesis studies is challenging. Researchers have to determine whether and how to use adjusted and unadjusted quantitative findings in combination with each other and with qualitative findings. Methods- Among quantitative findings, adjustment for confounding, either via study design or statistical analysis, can be a considerable source of heterogeneity. Yet there is no consensus about the best way to synthesize findings resulting from different methods for addressing confounding. When synthesizing qualitative and quantitative findings, additional consid...

2011-01-01

293

Aicardi syndrome: a case report and radiologic findings; Sindrome de Aicardi: relato de caso e achados radiologicos  

Energy Technology Data Exchange (ETDEWEB)

The authors report the findings of Aicardi syndrome, a disease of unknown etiology composed of multiple spasms, chorioretinal lacunae and agenesis of the corpus callosum. They present a case of Aicardi syndrome with characteristic clinical presentation and magnetic resonance imaging findings. The disease, despite being considered rare, has characteristic imaging findings. Over the past years magnetic resonance imaging has improved its ability in demonstrating other findings besides agenesis of the corpus callosum, making the radiologist's role very important in the diagnostic suspicion of this disease. (author)

2008-07-01

294

X-ray scattering signatures of {beta}-thalassemia  

Energy Technology Data Exchange (ETDEWEB)

X-ray scattering from lyophilized proteins or protein-rich samples is characterized by the presence of two characteristic broad peaks at scattering angles equivalent to momentum transfer values of 0.27 and 0.6 nm{sup -1}, respectively. These peaks arise from the interference of coherently scattered photons. Once the conformation of a protein is changed, these two peaks reflect such change with considerable sensitivity. The present work examines the possibility of characterizing the most common cause of hemolytic anaemia in Egypt and many Mediterranean countries; {beta}-thalassemia, from its X-ray scattering profile. This disease emerges from a genetic defect causing reduced rate in the synthesis of one of the globin chains that make up hemoglobin. As a result, structurally abnormal hemoglobin molecules are formed. In order to detect such molecular disorder, hemoglobin samples of {beta}-thalassemia patients are collected, lyophilized and measured using a ...

2009-08-11

295

Value of ultrasonography, Ct and MR imaging in the diagnosis of primary hyperparathyroidism  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluate the significance of preoperative localization of abnormal parathyroid glands to the surgical outcome in patients with primary hyperparathyroidism. Material and Methods: Thirty-nine patients with primary hyperparathyroidism were studied preoperatively with US (39 patients), CT (30 patients) and MR imaging (18 patients). The overall diagnostic accuracy for US was 87%, CT 66% and MR 94%. In patients with a single parathyroid adenoma US was the most cost-effective localization technique with a detection rate of 96%. CT had a lower detection rate (78%) but was of particular value for fairly large ectopic adenomas in the root of the neck. MR imaging was a good confirmatory test (93%). In patients with multiple gland disease (primary hyperplasia and multiple adenomas), no single localization study alone was sufficient. Combination of all 3 studies, however, alerted the physician to the presence of disease in more than one gland in 87% of these ...

1996-09-01

296

Repeated quantitative bone scintigraphy in patients with prostatic carcinoma treated with orchiectomy  

Energy Technology Data Exchange (ETDEWEB)

Bone scintigraphy was performed in 16 men with newly diagnosed prostatic carcinoma before orchiectomy as well as 2 weeks and 2 months after operation. The uptake in the lower thoracic and lumbar vertebrae was registered up to 240 min after injection of /sup 99m/Tc-MDP and was then calculated for each patient and vertebra. The relative standard deviation in measured uptake due to measuring technique was estimated to be +-7%. In eight patients, who had normal bone scintigraphies before orchiectomy, there were no changes in the uptake values after operation. The remaining eight patients had widespread metastatic involvement prior to treatment, six of these patients showed a so-called 'flare phenomenon' in the abnormal vertebrae which means an initial increase in uptake after operation followed by a decreased uptake in response to therapy. One patient had a continuously increased uptake in all the abnormal vertebrae which ...

1988-07-01

297

Repeated quantitative bone scintigraphy in patients with prostatic carcinoma treated with orchiectomy  

International Nuclear Information System (INIS)

Bone scintigraphy was performed in 16 men with newly diagnosed prostatic carcinoma before orchiectomy as well as 2 weeks and 2 months after operation. The uptake in the lower thoracic and lumbar vertebrae was registered up to 240 min after injection of "9"9"mTc-MDP and was then calculated for each patient and vertebra. The relative standard deviation in measured uptake due to measuring technique was estimated to be #+-#7%. In eight patients, who had normal bone scintigraphies before orchiectomy, there were no changes in the uptake values after operation. The remaining eight patients had widespread metastatic involvement prior to treatment, six of these patients showed a so-called 'flare phenomenon' in the abnormal vertebrae which means an initial increase in uptake after operation followed by a decreased uptake in response to therapy. One patient had a continuously increased uptake in all the abnormal vertebrae which correlated well with the ...

298

Quantitative bone scintigraphy in prostatic carcinoma - long-term response to treatment  

Energy Technology Data Exchange (ETDEWEB)

Quantitative bone scintigraphy was performed in 24 patients with prostatic carcinoma before orchiectomy and up to one to four years after operation. The gamma camera count rate was recorded over the lower thoracic and all lumbar vertebrae 4 h after injection of [sup 99m]Tc-MDP. Twelve patients has normal bone scintigrams throughout the study. They showed from two years after operation a slight increase in count rate values compared with the preoperative values, probability due to hormonal changes after orchiectomy and to age-related alterations in skeletal metabolism. Twelve patients had abnormal bone scintigrams. They showed as a response to treatment the flare phenomenon with an increase in count rate over the abnormal vertebrae when measured two weeks after operation followed by a decrease after two months. The lowest count rate values were obtained between six months and one year after operation. Thereafter the count rate seemed to remain ...

1993-10-01

299

Quantitative bone scintigraphy in prostatic carcinoma - long-term response to treatment  

International Nuclear Information System (INIS)

Quantitative bone scintigraphy was performed in 24 patients with prostatic carcinoma before orchiectomy and up to one to four years after operation. The gamma camera count rate was recorded over the lower thoracic and all lumbar vertebrae 4 h after injection of "9"9"mTc-MDP. Twelve patients has normal bone scintigrams throughout the study. They showed from two years after operation a slight increase in count rate values compared with the preoperative values, probability due to hormonal changes after orchiectomy and to age-related alterations in skeletal metabolism. Twelve patients had abnormal bone scintigrams. They showed as a response to treatment the flare phenomenon with an increase in count rate over the abnormal vertebrae when measured two weeks after operation followed by a decrease after two months. The lowest count rate values were obtained between six months and one year after operation. Thereafter the count rate seemed to remain on ...

300

Predominant and common cause of urinary tract infection(s) in sukkur city  

International Nuclear Information System (INIS)

To examine and evaluate the predominant and common etiologic agent(s) of urinary tract infection (UTI) in Sukkur city and to determine their current antibiotic susceptibility/resistance trends. Nine hundred sixty six patients out of 1430 abnormal urine reports (showing significant abnormalities such as protein, pus, red cells) were asked to give second sample. The urine samples were examined by both urine test strip (Combur 10 Test, Roche) and microscopically (wet preparation) followed by culture and sensitivity. The culture sensitivity was done on urine samples of which bacterial numbers were estimated as more than 105CFU. The study was conducted at Safeway Diagnostic and Research Laboratory Sukkur and the Department of Microbiology, Shah Abdul Latif University Khairpur, Sindh from March 2001 to March 2003. Eight hundred fifty-two (88.2%) showed Escherichia spp followed by Klebsiella spp (6.9%) and proteus spp (4.9%). These showed 95%, 90%, ...

2001-03-01

301

Normal and abnormal water diffusion in the brain  

International Nuclear Information System (INIS)

Diffusion magnetic resonance imaging (MRI) has become an important tool in the radiologic diagnosis of diseases of the brain as it measures molecular motion of water that characterizes the microstructure of tissues. Its most important clinical use to date is the early detection of cerebral ischemia by revealing the ischemic injury shortly after vessel occlusion and simultaneously providing therapy-relevant information on the tissue at risk. Furthermore, diffusion MRI is diagnostically promising in other diseases of the brain and is thus increasingly becoming part of routine clinical protocols in the diagnosis of tumors, inflammation, trauma, demyelination, dysmyelination and neurodegeneration. Although abnormalities of diffusion are generally not pathognomonic, diffusion MRI affords information about tissue changes for specific disorders that complements information obtained with standard MR techniques and frequently shows pathology earlier. In addition, diffusion ...

2003-10-01

302

Health-hazard evaluation report HETA 85-354-1872, Asarco, Denver, Colorado  

Science.gov (United States)

An evaluation was made of possible hazardous working conditions at the ASARCO Globe facility, Denver, Colorado. The facility was involved in the recovery of cadmium from baghouse dust, a waste byproduct of nonferrous smelters. A medical study of kidney function was conducted in 45 current or former cadmium production workers; results were compared to those for 35 hospital workers. Kidney abnormalities were more common and more severe in the cadmium workers than in the hospital workers. Abnormalities of proximal tubular function included reduced reabsorption of beta-2-microglobulin, retinol binding protein, calcium and phosphate. Glomerular dysfunction was evidenced as elevated serum creatinine. As length of exposure to cadmium increased, changes became more apparent in workers. No reversal of the conditions was noted in workers who had ceased to be exposed to cadmium some time before the study. The authors conclude that occupational ...

1988-02-01

303

Fault detection by Turam TEM survey. Numerical model studies and a case history; TEM ho Turam sokutei haichi ni yoru danso kenshutsu no kokoromi. Model keisan to jisshirei  

Energy Technology Data Exchange (ETDEWEB)

With an objective to detect faults estimated to exist along the Shigesumi valley in the Kamioka mine, discussions were given by using electromagnetic survey, which uses the Turam measurement arrangement based on the TEM method, and three-dimensional model calculations. The Turam measurement arrangement, which installs transmission loop fixedly, is used to identify nature and distribution of electrically conductive objects upon noticing abnormal portions in magnetic fields in the measurement data. In the model calculation, the plate model calculation method and the FDTD method were used, and so was the calculation code TEM3DL. The result revealed that strong topographical influence is seen from steep V-shaped valley existing along the traverse line in the measurement data, but an abnormal resistivity band accompanying remarkable distortion in the curve was detected. According to the result of the model calculation, anomaly detection may be found ...

1997-05-27

304

Fault detection and fault diagnosis system for engine; Engine no kosho yochi shindan system  

Energy Technology Data Exchange (ETDEWEB)

The fault detection and diagnosis system for gas engines was developed to improve the reliability of cogeneration systems (CGS). Most of existing fault detection systems monitor the trend of each part condition of engines and diagnose faults based on trend change, resulting in slow detection. Although early detection systems are available, those are complex, expensive and poor in flexibility and applicability. Since CGSs combined with gas engines increased to 1/3 of the whole CGS, engine troubles cause possible serious faults. The fault diagnosis system was thus developed to prevent serious faults which can early detect, in particular, abnormal conditions of parts around a combustion chamber such as ignition plug, intake valve and exhaust valve by monitoring exhaust pressure waveforms in an exhaust collector. Since this system can detect progressive occurrence frequency of abnormal conditions and degradation of engine parts, it can transfer ...

1996-03-29

305

Effect of iron and boron carbide on the densification and mechanical properties of titanium diboride ceramics  

Energy Technology Data Exchange (ETDEWEB)

The effects of Fe and B{sub 4}C on the sintering behavior and mechanical properties of TiB{sub 2} ceramics have been studied. Sintering was performed in an Ar atmosphere at 2000{degrees}C using attrition-milled TiB{sub 2} powder. When a small amount of Fe (0.5 wt%) was added, abnormal grain growth occurred and the sintered density was low. In the case of B{sub 4}C added along with 0.5 wt% Fe, however, abnormal grain growth was remarkably suppressed, and the sintered density was increased up to 95% of theoretical. But with excess Fe addition (5 wt%), B{sub 4}C grains did not act as a grain growth inhibitor, and B{sub 4}C grains were frequently trapped in large TiB{sub 2} grains. The best mechanical properties were obtained for the TiB{sub 2}-10 wt% B{sub 4}C-0.5 wt% Fe ceramics, which exhibited a three-point bending strength of 400 MPa and a fracture toughness of 5.5 MPa {center dot} m{sup 1/2}.

1989-10-01

306

Effect of iron and boron carbide on the densification and mechanical properties of titanium diboride ceramics  

International Nuclear Information System (INIS)

The effects of Fe and B_4C on the sintering behavior and mechanical properties of TiB_2 ceramics have been studied. Sintering was performed in an Ar atmosphere at 2000 degrees C using attrition-milled TiB_2 powder. When a small amount of Fe (0.5 wt%) was added, abnormal grain growth occurred and the sintered density was low. In the case of B_4C added along with 0.5 wt% Fe, however, abnormal grain growth was remarkably suppressed, and the sintered density was increased up to 95% of theoretical. But with excess Fe addition (5 wt%), B_4C grains did not act as a grain growth inhibitor, and B_4C grains were frequently trapped in large TiB_2 grains. The best mechanical properties were obtained for the TiB_2-10 wt% B_4C-0.5 wt% Fe ceramics, which exhibited a three-point bending strength of 400 MPa and a fracture toughness of 5.5 MPa #centre dot# m"1"/"2.

307

Combining anatomy and function: the path to true image fusion  

Energy Technology Data Exchange (ETDEWEB)

Modern imaging technologies visualize different aspects of disease in a non-invasive way. Considerable progress has been made in the fusion of images from different imaging modalities using software approaches. One goal of fusion software is to align anatomical and functional images and allow improved spatial localization of abnormalities. The resulting correlation of the anatomical and functional images may clarify the nature of the abnormality and help diagnose or stage the underlying disease. Whereas successful image fusion software has been developed for the brain, only limited success has been achieved for image alignment in other parts of the body. The development and current status of alternative approaches are presented. Dual-modality imaging is described with devices where two modalities are combined and mounted in a single gantry. The use of existing scanner technology ensures that no compromises are made in the clinical efficacy of ...

2001-10-01

308

Chromosome mapping of human CDC25A and CDC25B phosphatases  

Energy Technology Data Exchange (ETDEWEB)

The human CDC25 tyrosine phosphatases trigger activation of CDC2 by removing inhibitory phosphates; thus the genes encoding these phosphatases may be suspected as potential oncogenes due to their role in promoting cell division. To date, three human CDC25 genes have been identified: CDC25A, B, and C. This communication describes the mapping of CDC25A to chromosome 3p21 and CDC25B to chromosome 20p13 by fluorescence in situ hybridization with confirmation by the polymerase chain reaction of hamster-human somatic cell hybrid DNA. 3p21 is near an area frequently involved in karyotypic abnormalities in renal carcinomas, small cell carcinomas of the lung, and benign tumors of the salivary gland. 20p13 does not seem to be a common area for karyotypic alteration in tumors. Mapping of these genes to their chromosomal loci may help identify tumors with abnormal regulation of CDC25 genes due to genomic alterations. 15 refs., 3 figs.

1993-10-01

309

Chemical behavior of europium oxides in- LiCI-KCI eutectic melt  

Energy Technology Data Exchange (ETDEWEB)

The electrochemical behavior of lanthanide oxides in molten alkaline chloride media is of great concern in pyrochemical processes for advanced nuclear fuel cycle. We have studied the solubilities of various lanthanide oxides in LiCl-KCl eutectic melt. In general, lanthanide oxides appeared to be insoluble/sparingly soluble in LiCl-KCl eutectic at 723 K. However, europium oxide exhibited an abnormal behavior in solubility and redox chemistry. The solubility of europium oxide was measured to be 1-2 order of magnitude higher than those of other lanthanide oxides. This abnormal solubility may be attributable to different electrochemical behavior of europium in the same experimental conditions. Most lanthanides ion exists as trivalent oxidation states. However, we observed divalent europium dissolved in LiCl-KCl molten salt by applying electron paramagnetic resonance(EPR) spectroscopy. (Figure 1) With the aid of this spectroscopic tool, it was found ...

2005-06-15

310

Abnormal phase transition in BiNbO4 powders prepared by a citrate method  

British Library Electronic Table of Contents (United Kingdom)

Triclinic b-BiNbO4 prepared below 750^oC and above 1040^oC (denoted as Low-b and High-b, respectively) and pure orthorhombic a-BiNbO4 at 900^oC were successfully derived from a citrate method and the phase transition from b-BiNbO4 to a-BiNbO4 was first observed in BiNbO4 powders. This phenomenon proves that the abnormal phase transition from b-BiNbO4 to a-BiNbO4 exists in BiNbO4 powder system. The synthesis of Low-b powders can be attributed to the formation of the intermediate phase of Bi5Nb3O15 by the citrate method. With increasing temperature, the Low-b phase gradually turns into a-BiNbO4 due to the thermodynamically metastable state of Low-b. We also identified that the stress in pellet format can accelerate the phase transition from Low-b to a phase of BiNbO4 in comparison with powde...

2011-01-01

311

Utility of CT in the diagnosis of psoitis  

International Nuclear Information System (INIS)

A 65-year-old woman who was diagnosed as having psoitis by CT findings, which disclosed non-symmetrical dilation of the psoas muscle and gaseous image. Pus from the psoas muscle seen at surgery corresponded to CT findings. Preoperative CT examination was useful in the establishment of diagnosis. (Namekawa, K.).

1984-01-01

312

High-Speed Ultrahigh-Resolution Optical Coherence Tomography Findings in Chronic Solar Retinopathy  

UK PubMed Central (United Kingdom)

PurposeTo describe ocular findings for a 34-year-old man with chronic solar retinopathy using high-speed ultrahigh-resolution (UHR) optical coherence tomography (OCT).Full Text Available

2008-01-01

313

Endometrial biopsy in Holstein-Friesian dairy cows. III. Bacteriological analysis and correlations with histological findings.  

UK PubMed Central (United Kingdom)

This study examines the results of bacterial culture from 159 endometrial biopsy samples from 97 commercial dairy cows and correlations between bacteriological and histological findings. Bacteria were...Full Text Available

1991-04-01

314

Chorionic villi sampling: cytogenetic and clinical findings in 500 pregnancies.  

UK PubMed Central (United Kingdom)

The cytogenetic findings were analysed in a series of 500 pregnancies in which chorionic villi sampling was performed. In all cases a direct method was used, karyotyping being successful in 481 cases...Full Text Available

1987-08-15

315

Vapor fraction measurements in a steam-water duct at atmospheric pressure using neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Real-time neutron radiography has been used to study the dynamic behavior of two-phase flow and measure vapor fractions in a steam-water duct at atmospheric pressure. This unique experimental technique offers one the opportunity to observe and record on videotape now Patterns and transient behavior of two-phase flow inside opaque containers without perturbing the environment. The neutron radiographic technique is non-intrusive and requires no special transparent window region. Data are recorded simultaneously over a large area of interest. Image processing of the video data can be employed to measure bubble velocities and time-averaged and Instantaneous vapor fractions.

1994-11-11

316

Sex determination using discriminant function analysis in children and adolescents: a lateral cephalometric study  

British Library Electronic Table of Contents (United Kingdom)

The objective of this study is to test the validity of sex determination in children and adolescents using lateral radiographic cephalometry and discriminant function analysis. Fifty male and 50 female cephalograms of Taiwanese children were used (males and females with mean age of 15.52???1.38 and 15.67???1.54?years, respectively). Twenty-two cephalometric measurements were performed using computerized cephalometry. Statistical analysis shows that all measurements were sexually dimorphic (p?

2010-01-01

317

Revisited the mathematical derivation wall thickness measurement of pipe for radiography  

Energy Technology Data Exchange (ETDEWEB)

Wall thickness measurement of pipe is very important of the structural integrity of the industrial plant. However, the radiography method has an advantage because the ability of penetrating the insulated pipe. This will have economic benefit for industry. Moreover, the era of digital radiography has more advantages because the speed of radiographic work, less exposure time and no chemical used for film development. Either the conventional radiography or digital radiology, the wall thickness measurement is using the tangential radiography technique (TRT). In case, of a large diameter, pipe (more than inches) the determination maximum penetration wall thickness must be taken into the consideration. This paper is revisited the mathematical derivation of the determination of wall thickness measurement based on tangential radiography technique (TRT). The mathematical approach used in this derivation is the Pythagoras theorem and geometrical principles. In order to ...

2007-07-01

318

Retinue of the beans roots growth by using neutron radiography technique  

International Nuclear Information System (INIS)

Agricultural practices frequently cause the development of a soil compacted layer below the surface. These compacted layers restrict the root penetration into deeper layers of soil, in search for water. It is proposed to monitor, using Non Destructive Test, the roots growth due to the planting of standard seeds in different agricultural soils, in function of their compactness and humidity. It will be used the neutrons beams derived from an irradiation channel called J-9 of the Reactor Argonauta (IEN/CNEN), so that the neutron radiographic images of the soil-plant system can be obtained. Each root can be evaluated for its ability to penetrate into compacted soil layers; this fact would mean an optimization of agricultural harvests. (author)

2002-08-11

319

Removal of scattered thermal neutrons using antiscatter grid  

International Nuclear Information System (INIS)

One of the significant factors of neutron radiographic image degradation is scattering blur from the object. A practical method is described to enhance image quality by eliminating the overlapping of scattered thermal neutrons component from the objects in ETRR-2 neutron radiography facility, using aluminum Gd-coated antiscatter grid. The MCNP code was used to determine the optimum grid dimensions that will reduce the scattered thermal neutrons from the object. An experiment was performed to determine the optimum grid height and irradiation time that gives the best image with acceptable geometric unsharpness. Using the MCNP code it was found that 97% of the scattered neutrons were removed by the grid. The wall dimensions and Gd coating are so small that the facility resolution cannot detect the image pattern superposition on the film.

2006-12-01

320

Orthognathic treatment case after severe root resorption in the early treatment stage  

British Library Electronic Table of Contents (United Kingdom)

This article presents an orthognathic treatment case after severe apical root resorption of maxillary anterior teeth using anterior segmental osteotomy. This case involved a 20-year-old female with the chief complaint of maxillary protruding and irregularly aligned mandibular anterior teeth. Her medical history showed no allergies or medical problems. The overbite was +3.0mm, and the overjet +3.0mm. After extraction of the four first premolars, a multi-bracket treatment was started. A severe root resorption of the maxillary anterior teeth was found 12 months after active treatment. The maxillary anterior segmental osteotomy was chosen as the compensatory treatment. The total treatment period was 2 years and 7 months. The post-retention panoramic radiograph showed no developmental root reso...

2009-01-01

321

Neutron radiography with the cyclotron, 5. Cyclotron-based real time neutron fluoroscopy system and its application for some industrial components  

Energy Technology Data Exchange (ETDEWEB)

Reliable facility of cyclotron-based real time neutron radiography system has been developed and applied to some industrial components. The equipment for neutron fluoroscopy is based on a sub-compact cyclotron and a LiF/ZnS (Ag) fluorescent screen viewed by a silicon intensifier target TV camera. The real time image is monitored on a CRT, recorded with a standard video recorder and processed by a digital image processor. The effectiveness of our real time neutron radiograph has been demonstrated to be applicable to not only the dynamic observation but also the magnifying and stereoscopic observation of fluoroscopic images.

1987-03-01

322

Imaging automation and volume tomographic visualization at Texas Neutron Imaging Facility  

Energy Technology Data Exchange (ETDEWEB)

A thermal neutron imaging facility for real-time neutron radiography and computed tomography has been developed at the University of Texas reactor. The facility produced a good-quality radiographs and two-dimensional tomograms. Further developments have been recently accomplished. Further developments have been recently accomplished. A computer software has been developed to automate and expedite the data acquisition and reconstruction processes. Volume tomographic visualization using Interactive Data Language (IDL) software has been demonstrated and will be further developed. Volume tomography provides the additional flexibility of producing slices of the object using software and thus avoids redoing the measurements.

1999-07-01

323

Functional and Oncologic Outcomes of Partial Adrenalectomy for Pheochromocytoma in Patients With von Hippel-Lindau Syndrome After at Least 5 Years of Followup  

British Library Electronic Table of Contents (United Kingdom)

PurposeAlthough the safety and feasibility of partial adrenalectomy in patients with von Hippel-Lindau syndrome have been established, long-term outcomes have not been examined. In this study we evaluate the recurrence and functional outcomes in a von Hippel-Lindau syndrome cohort treated for pheochromocytoma with partial adrenalectomy with a followup of at least 5 years. Materials and MethodsWe reviewed the records of patients with von Hippel-Lindau syndrome treated with partial adrenalectomy for pheochromocytoma at the National Cancer Institute. Demographic, germline mutation status, surgical indication, oncologic and functional outcome data were collected. Local recurrence was defined as radiographic evidence of recurrent tumor on the ipsilateral side of partial adrenalectomy. Patients ...

2010-01-01

324

Five-year Changes in Periodontal Parameters after Apical Surgery  

British Library Electronic Table of Contents (United Kingdom)

IntroductionMost clinical studies on the outcome of apical surgery concentrate on periapical healing based on radiographic and clinical characteristics (signs and symptoms). This study focuses on long-term changes in periodontal parameters after apical surgery. MethodsPeriodontal parameters (ie, probing depth [PD], level of gingival margin [GM], and calculated clinical attachment level [CAL]) were collected at baseline and at 1 and 5 years after apical surgery. Changes in PD, GM, and CAL were calculated over time and were also evaluated in relation to patient-, tooth-, and treatment-related covariables. ResultsOne hundred eighty-six of 242 initially identified teeth could be evaluated. Significant changes in GM and CAL were observed at facial sites during the first year after surgery (mean...

2011-01-01

325

Evaluation of diagnostic digital radiography of the chest in comparison with conventional chest x-ray films  

International Nuclear Information System (INIS)

Digital radiography for diagnosis of chest diseases using Fuji Computed Radiography (FCR) was evaluated. The results were as follows; 1. Compared to the conventional chest X-ray films, various types of image enhancement could be made by manipulation of the digital information such as tone conversion, spatial frequency modification etc. 2. Digital radiography lessens the X-ray exposure dose and will ultimately permit speedy transmission of image data from outlying clinics to central processing hospitals. 3. Digital radiographic images are useful in chest X-ray diagnosis especially in mass surveys for lung cancer and in primary care medicine because of its full imaging capability. (author).

1983-01-01

326

Case?control study of knee osteoarthritis and lifestyle factors considering their interaction with physical workload  

British Library Electronic Table of Contents (United Kingdom)

Aims The aim of this study is to examine the dose?response relationships between age, ?lifestyle factors?? (body mass index, tobacco smoking, sports), and symptomatic knee osteoarthritis in a population-based case?control study. Additionally, the study aims to investigate the mode of interaction between body mass index (BMI) and physical workload (occupational kneeling/squatting and lifting/carrying of loads) with respect to the risk of symptomatic knee osteoarthritis. Methods In five orthopedic clinics and five practices, 295 male patients aged 25?70 with radiographically confirmed knee osteoarthritis associated with chronic complaints were recruited. The control group comprised 327 male control subjects. In a structured personal interview, body weight at different ages, body height, cumu...

2010-01-01

327

A retrospective study of canine hip dysplasia in 116 military workingn> dogs. Part II: Clinical signs and performance data.  

Science.gov (United States)

The progression of hip dysplasia was investigated in 116 military working dogs. Medical records were reviewed for any clinical history of hind-limb lameness. Pelvic radiographs were studied for evidence and degree of hip dysplasia, degenerative joint disease, or both. The number of months each dog worked was determined. Each dog's age at termination from service and cause of death (or euthanasia) were recorded. The mean months of work for normal and dysplastic dogs were evaluated using the Student's t-test. No significant difference was found in the total number of months worked between normal and dysplastic dogs (p greater than 0.05). PMID:8875358

328

A retrospective study of canine hip dysplasia in 116 military workingn> dogs. Part I: Angle measurements and orthopedic foundation for animals (OFA) grading.  

Science.gov (United States)

The progression of hip dysplasia was investigated in 116 military working dogs. Serial pelvic radiographs were graded for degree of dysplasia and degenerative joint disease (DJD). Norberg angles, angles of inclination, and joint space widths were measured. There was a significant correlation between the Norberg angle and the degree of dysplasia (p less than 0.0001). Angles of inclination and joint space width measurements did not demonstrate a correlation to canine hip dysplasia. Dysplastic dogs had a significant estimated risk for development of DJD compared to normal dogs (p less than 0.0001; odds ratio of 70.2). Dogs with normal hip conformation at 24 months of age or older did not develop moderate nor severe DJD. PMID:8875357

329

The value of computed tomography in the diagnosis of grating scapula  

Energy Technology Data Exchange (ETDEWEB)

Snapping or grating scapula is a condition of the shoulder girdle in which the patient complains of pain and an audible snapping sound which may be associated with pain. We evaluated the diagnostic value of the computed tomography (CT) scans using the clinical diagnosis of a grating scapula as the gold standard. This retrospective study reports the sensitivity, specificity, likelihood ratio and receiver operator characteristic curve for the CT scans and the k value as a measure of the interobserver agreement. None of the parameters validated the examination. We therefore concluded that CT scans are inappropriate for differentiation between a grating scapula and a normally functioning shoulder except in cases where bony abnormalities are present. (orig.)

1994-07-01

330

The development of a centralized automatic monitoring system for coal mines: composition and functions of the system  

Energy Technology Data Exchange (ETDEWEB)

A centralized, automatic monitoring system for coal mines has been developed. The system consists of newly-developed and improved sensors, transmission equipment, a minicomputer designed for scientific and technical calculations, and accompanying software (MOLES). MOLES performs six functions: input, computation, decision, memory, output and correction. Previously, centralized monitoring has been limited to single dimensional monitoring of the 'time and point' type. The present system carries out data analysis and processing with respect to time, space and item. It is also capable of simple automatic diagnosis of abnormalities. (In Japanese)

1983-01-01

331

State-of-the-art technique for power system stabilizer tuning  

Energy Technology Data Exchange (ETDEWEB)

Power System Stabilizers (PSS) have broad application throughout the world. PSS application requires careful tuning which is usually accomplished in the field with the generator and power system in an abnormal condition. Recently developed equipment which combines fast Fourier transform capability with digital computer technique provides a means of PSS tuning which is faster and more accurate than was previously obtainable. This paper describes a PSS tuning test conducted using the new technique. The advantages will be apparent to the reader. The described test is very poignant as evidenced by two unexpected occurrences of instability.

1983-03-01

332

Results of the 2nd periodical inspection of the asphalt solidification facility and the incinerator in Unit 2 of the Sendai Nuclear Power Station  

International Nuclear Information System (INIS)

The 2nd periodical inspection was carried out on the asphalt solidification facility and the incinerator in Unit 2 of the Sendai Nuclear Power Station from November 5 to 28, 1985. Inspection was made in radiation control facility and disposal facility. By external appearance, disassembly, function and performance tests there were observed no abnormalities. The personnel exposure doses during the inspection were below the permissible level. In the inspection, improvement etc. works were not done. (Mori, K.).

1986-01-01

333

Results of regular inspection of No.2 plant in Sendai Nuclear Power Station, Kyushu Electric Power Co., Inc  

International Nuclear Information System (INIS)

The regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from January 7 to February 8, 1985. The summary of the results of this regular inspection is as follows. The facilities as the object of inspection were radiation control facilities and waste facilities. On these facilities as the object of inspection, the appearance, disassembling, functional, performance and other inspections were carried out, and as the results, abnormality was not found at all. The works related to this regular inspection were accomplished within the range of the allowable radiation dose based on the relevant laws. (Kako, I.).

1986-01-01

334

Recrystallization during and following hot working of magnesium alloy AZ31  

Energy Technology Data Exchange (ETDEWEB)

The microstructures of magnesium AZ31 are examined following hot compression testing and annealing. The grain size, fraction dynamically recrystallized and, in a couple of cases, the crystallographic texture are reported. It was found that the progress of dynamic recrystallization is strongly sensitive to processing conditions but that the dynamically recrystallized grain size was less sensitive to stress than in other metals. It was also found that, for structures containing between 80 and 95% dynamic recrystallization, abnormal grain growth occurs during annealing. The crystallographic texture produced is also sensitive to the deformation conditions. (orig.)

2003-07-01

335

Recent advances in pharmacotherapy for dyspnea in COPD  

British Library Electronic Table of Contents (United Kingdom)

Dyspnea is the most distressing symptom experienced by those suffering from advanced stages of chronic obstructive pulmonary disease (COPD). Activity-related dyspnea in COPD is multifactorial but is associated with increased central neural drive, impaired dynamic respiratory mechanics and abnormal respiratory muscle function. Each of these components can potentially be targeted for pharmacotherapy. Recent advances in the pharmacotherapy of COPD include the development of new long-acting bronchodilators which, when combined, provide sustained improvements in dyspnea. Additionally, novel applications of older therapies such as opiates, furosemide, helium-oxygen, and statins show early promise as dyspnea-relieving interventions in COPD. Effective pharmacological manipulation of the affective ...

2011-01-01

336

Randomization of heavily damaged regions in annealed low energy Ge{sup +}-implanted (0 0 1)Si  

Energy Technology Data Exchange (ETDEWEB)

Apparent growth of amorphous layers during low temperature annealing was observed in low energy Ge{sup +}-implanted (0 0 1)Si by high-resolution transmission electron microscopy. The occurrence of abnormal growth is due to the randomization of heavily damaged regions beneath the original amorphous/crystalline interfaces. The randomization process is attributed to the strain, incurred by the presence of a high density of large Ge atoms in the heavily damaged Si substrate, relaxation to lower the free energy of the systems. The randomization upon annealing may be fruitfully applied to minimize the transient enhanced diffusion in shallow junction formation.

2004-01-15

337

Randomization of heavily damaged regions in annealed low energy Ge"+-implanted (0 0 1)Si  

International Nuclear Information System (INIS)

Apparent growth of amorphous layers during low temperature annealing was observed in low energy Ge"+-implanted (0 0 1)Si by high-resolution transmission electron microscopy. The occurrence of abnormal growth is due to the randomization of heavily damaged regions beneath the original amorphous/crystalline interfaces. The randomization process is attributed to the strain, incurred by the presence of a high density of large Ge atoms in the heavily damaged Si substrate, relaxation to lower the free energy of the systems. The randomization upon annealing may be fruitfully applied to minimize the transient enhanced diffusion in shallow junction formation.

2004-01-01

338

Quantitative bone scintigraphy in the evaluation of angular deformity of the lower extremity  

International Nuclear Information System (INIS)

A technique for quantitative analysis of growth plates in varus or valgus deformity about the knee has been developed. Computer-generated regions of interest are placed on magnification scintigraphs to divide distal femoral and proximal tibial physes into four equal segments. The ratio of counts in the medial half to counts in the lateral half was studied in 31 children (22 normal, 9 with angular deformity). Normal ratios were 0.74 to 0.98 for femora and 0.98 to 1.20 for tibias. In eight of nine patients with deformity, the ratio was abnormal; in two patients the ratio returned to normal when the deformity ceased to progress.

339

Mechanisms Underlying Visceral Hypersensitivity in Irritable Bowel Syndrome  

British Library Electronic Table of Contents (United Kingdom)

Visceral hypersensitivity is currently considered a key pathophysiological mechanism involved in pain perception in large subgroups of patients with functional gastrointestinal disorders, including irritable bowel syndrome (IBS). In IBS, visceral hypersensitivity has been described in 20%?90% of patients. The contribution of the central nervous system and psychological factors to visceral hypersensitivity in patients with IBS may be significant, although still debated. Peripheral factors have gained increasing attention following the recognition that infectious enteritis may trigger the development of persistent IBS symptoms, and the identification of mucosal immune, neural, endocrine, microbiological, and intestinal permeability abnormalities. Growing evidence suggests that these factors ...

2011-01-01

340

Effects of gamma irradiation on the sperm transmission and oviposition response in Helicoverpa armigera (L. NOCTUIDAE)  

International Nuclear Information System (INIS)

Transmissions of sperm by unirradiated and irradiated cotton bollworm, Helicoverpa armigera, were studied by live dissection of females immediately after the initiation of mating. In cotton bollworm the sperm transfer was rather a complex process. In fact unirradiated males failed to transfer sperm in about 19% of their matings. When irradiated with 250 Gy and 400 Gy, aberrations of sperm transmission were about 21% and 50% respectively. The failure of spermatophore 'cap' location was an important reason of sperm transmission aberrations. When females mated to high-dose-irradiated males, their oviposition response appeared abnormal

2002-02-01

341

Confocal Imaging of Biological Tissues Using Second Harmonic Generation  

Energy Technology Data Exchange (ETDEWEB)

A confocal microscopy imaging system was devised to selectively detect Second harmonic signals generated by biological tissues. Several types of biological tissues were examined using this imaging system, including human teeth, bovine blood vessels, and chicken skin. All these tissues generated strong second harmonic signals. There is considerable evidence that the source of these signals in tissue is collagen. Collagen, the predominant component of most tissues, is known to have second order nonlinear susceptibility. This technique may have diagnostic usefulness in pathophysiological conditions characterized by changes in collagen structure including malignant transformation of nevi, progression of diabetic complications, and abnormalities in wound healing.

2000-03-06

342

Computer tomographic demonstration of so-called azygos continuation in the absence of the hepatic segment of the inferior vena cava  

International Nuclear Information System (INIS)

Dilatation of the azygos vein is usually due to increased pressure or flow, rarely is it diopathic. Another cause is so-called continuation of the azygos in cases of absence of the hepatic segment of the inferior vena cava. The method of choice for the investigation of azygos dilatation nowadays is computer tomotgraphy. Anomalies of the inferior vena cava can be recognised in this way unequivocally by a non-invasive method. Computer tomography frequently shows important additional abnormalities (e.g. situs inversus, polysplenia), since it demonstrates all organs situated in the plane of section. (orig.).

343

Back pain in the osteoporotic individual: A physiatric approach  

British Library Electronic Table of Contents (United Kingdom)

Back pain from osteoporosis is commonly related to compression fractures. The patient with vertebral compression fractures additionally suffers from an ongoing risk of recurrent fractures and postural abnormalities that can result in impaired respiratory function, leading to increased risk of morbidity. Weakened back muscles, especially the back extensor group, are felt to contribute significantly to this risk. The combination of pharmacologic and nonpharmacologic interventions, through physical activity, exercise, and modalities, are potential interventions that could be used to help reduce the pain of osteoporotic compression fractures as well as potentially reducing recurrent fracture rates.

2011-01-01

345

The Analytic Methods of Operations Research  

Science.gov (United States)

... of the utility of the terminal outcomes, ... Other stochastic topics, such as random walks, branching ... find special uses, particularly in queueing theory ...

1977-01-01

346

Public Understanding of Cognitive Neuroscience Research Findings: Trying to Peer Beyond Enchanted Glass  

British Library Electronic Table of Contents (United Kingdom)

This article considers the appeal of cognitive neuroscience research to the general public within the context of the deep puzzles involved in using our minds to understand how our minds work. It offers a few promising examples of findings that illuminate the ways of the mind and reveal these workings to be counter-intuitive with our subjective experience. However, this promise is tempered by the powerful role that perception, attention, and cognition play in how we reason about evidence. It argues that the interplay between what we believe about the nature of our minds and what the findings suggest constitutes a primary challenge in encouraging public understanding of cognitive neuroscience findings.

2011-01-01

349

NAME=\\  

Wastenet

...Surface Aerators Products and Equipment Find and compare a variety of surface aerators products and equipment on the world's largest environmental industry portal. ...

350

NAME=\\  

Wastenet

...Extraction Arms Products and Equipment Find and compare a variety of extraction arms products and equipment on the world's largest environmental industry portal. ...

351

NAME=\\  

Wastenet

... Tunnel Composting Products and Equipment Find and compare a variety of tunnel composting products and equipment on the world's largest environmental industry portal. ...

352

NAME=\\  

Wastenet

... Radiation Protection Products and Equipment Find and compare a variety of radiation protection products and equipment on the world's largest environmental industry portal. View product ...

353

India's tryst with modern astronomy  

CERN Document Server

Sumedh Anathpindika surveys astronomy in India and finds a lively and developing community as well as great public interest.

2011-01-01

354

Early axial spondyloarthritis  

UK PubMed Central (United Kingdom)

Purpose of reviewTo summarize recent advances in the classification of preradiographic axial spondyloarthritis (SpA).Recent findingsFull Text Available

2010-09-01

355

/_// ;_/ AN INTERIM OVERVIEW OF LDEF MATERIALS FINDINGS  

Science.gov (United States)

FEP polyethylene mechanical properties affected by UV. " Siloxane-modified materials resist AO. " Nonsilicone polymers attacked by AO ...

356

Quantitative bone scintigraphy. A study in patients with prostatic carcinoma  

International Nuclear Information System (INIS)

Quantitative bone scintigraphy was performed in patients with prostatic carcinoma before orchiectomy as well as two weeks, two and six months after operation. The count rate was recorded as serial gamma camera images over the lower thoracic and all lumbar vertebrae from 1 to 240 min and at 24 h after injection of "9"9"Tc"m-MDP. In almost all abnormal vertebrae an increased count rate was observed within one hour after injection. Most of the vertebrae which were considered normal at 4 h after injection, but had an increased 24h/4h ratio developed into abnormal vertebrae later in the study. The patients with normal bone scintigrams showed no change in "9"9Tc"m-MDP uptake during the study. The reproducibility of quantitative bone scintigraphy was found to be #+-# 7% (1 SD). In response to therapy, most of the patients with abnormal bone scintigrams showed an increase in count rate two weeks after operation followed by a ...

1985-06-02

357

Mercury flow experiments. 3. Simulation test plan under abnormal condition  

Energy Technology Data Exchange (ETDEWEB)

Japan Atomic Energy Research Institute (JAERI) and High Energy Accelerator Research Organization (KEK) are promoting construction plan of Material-Life Science Facility, which is consisted of Muon Science Facility and Neutron Scattering Facility, in order to open up the new science fields. The Neutron Scattering Facility will be utilized for advanced fields of Material and Life science using high intensity neutrons generated by the spallation reaction induced by injecting a 1 MW pulsed proton beam onto a mercury target. Design of the spallation mercury target system is in progress to obtain good neutron performance keeping high reliability and safety. The target material is mercury. As a result of the spallation reaction, large amount of radioactive spallation products are to be contained in the mercury. Therefore to establish the safety of the target system, transient behaviors of the system during anticipated events should be well understood. The safety protection system and an ...

2002-02-01

358

Assessment of chromosomal abnormalities in sperm of infertile men using sperm karyotyping and multicolour fluorescence in situ hybridization (FISH)  

Energy Technology Data Exchange (ETDEWEB)

Individuals with male factor infertility resulting from idiopathic oligo-, astheno- or teratozoospermia are frequently offered IVF in an attempt to increase their chances of having a child. A concern remains whether these infertile males have an elevated risk of transmitting chromosomal abnormalities to their offspring. Sperm chromosomal complements from these men were assayed using the human sperm/hamster oocyte fusion system and fluorescence in situ hybridization (FISH) on sperm nuclei. For each of 5 infertile patients, 100 sperm karyotypes were analyzed and multicolour FISH analysis was performed on a minimum of 10,000 sperm nuclei for each chromosome-specific DNA probe for chromosomes 1 (pUC1.77), 12 (D12Z3), X (XC) and Y (DYZ3). As a group, the infertile patients showed increased frequencies of both numerical ({chi}{sup 2}=17.26, {proportional_to} <0.001) and total abnormalities ({chi}{sup 2}=7.78, {proportional_to} <0.01) relative ...

1994-09-01

359

X-ray findings in patients with miliary appearance of metallic mercury after suicide attempt  

Energy Technology Data Exchange (ETDEWEB)

This case report evaluates X-ray findings in patients with miliary accumulation of mercury observed after parenteral application of metallic mercury in a suizide attempt. There are certain discrepancies between clinical symptoms and the X-ray findings. A clear demonstration of mercury in coronary blood vessels is possible by fluoroscopy.

1985-03-01

360

Report on the special program 78 satellite geodesy of the technical university of Munich  

Energy Technology Data Exchange (ETDEWEB)

Various topics include: (1) direction finding, (2) range finding, (3) Doppler measurements, (4) construction of a receiver for radio interferometry, (5) mobile laser range finding system, (6) figure-and field parameter determination/geopotential, (7) dynamics of the Earth-Moon system, and (8) kinematics of geodetic point fields.

1981-01-01

361

Imaging findings of central nervous system neuroepithelial cysts  

Energy Technology Data Exchange (ETDEWEB)

Neuroepithelial cysts are rare and mostly asymptomatic cerebrospinal fluid (CSF)-like cysts. We describe herein the imaging findings in five patients with neuroepithelial cysts. Two cases of proven and three of presumed neuroepithelial cysts are presented. Three of five are located in the thalamus, a location which is not characteristic for neuroepithelial cysts. In the case of incidental finding of asymptomatic neuroepithelial cyst, clinical and radiological follow-up is indicated and surgical intervention is not necessarily warranted. (orig.) With 5 figs., 6 refs.

1998-05-01

362

FastBit -- Helps Finding the Proverbial Needle in a Haystack  

Energy Technology Data Exchange (ETDEWEB)

FastBit is a software package designed to meet the searching and filtering needs of data intensive sciences. In these applications, scientists are trying to find nuggets of information from petabytes of raw data. FastBit has been demonstrated to be an order of magnitude faster than comparable technologies. In this brief report, we highlight how we work with a visualization team, a network security team and a DNA sequencing center to find the nuggets in their data.

2006-07-05

363

CT scan findings in cerebral paragonimiasis  

International Nuclear Information System (INIS)

Computed tomography was performed on 5 patients with chronic cerebral paragonimiasis. CT showed solitary or multiple, amorphous, round, or oval calcifications, and ventricular enlargement in all 5 cases. A large low-density area is also found in 4 of the 5 cases. These CT findings are compatible with previously reported findings of simple X-ray films of the skull, pneumoencephalography, and pathological studies. (author).

1982-01-01

364

Evaluation of node involvement in non small cell bronchogenic carcinoma. CT-pathology correlation; Valutazione del fattore <<N>> nel carcinoma polmonare non a piccole cellule. Correlazione tra tomografia computerizzata e anatomia patologica  

Energy Technology Data Exchange (ETDEWEB)

The main purpose of this work is to evaluate the role of CT in identifying other morphological signs of met static lymph node involvement from non small cell bronchogenic carcinoma. This is done to improve N staging, a critical step in this disease. In fact, since diameter is the only criterion used to distinguish normal form abnormal lymph nodes, mediastinal CT only has 80% diagnostic accuracy. 137 patients with known or suspected lung cancer were examined with Helical CT during early and late arterial phases (2 min. delay, 3 mm thickness, 5 mm inter slice gap) to depict node characteristics. Mediastinal lymph nodes, located according to the American Thoracic Society mapping, were considered normal when they were not visible or, if visible, less than 1 cm in diameter and of homogeneous density; lymph nodes over 1 cm in diameter and homogenous density were considered reactive. A lymph node was considered metastatic when, independent of size, the following signs ...

2000-05-01

365

Radiation exposure of children in pediatric radiology, Pt. 8. Radiation doses during thoracoabdominal babygram and abdominal X-ray examination of the newborn and young infants; Zur Strahlenexposition von Kindern in der paediatrischen Radiologie. T. 8. Strahlendosen beim thorakoabdominalen babygramm und bei der abdomenaufnahme neugeborener und saeuglinge  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Reconstruction of radiation doses for the thoracoabdominal babygram and the abdomen X-ray from radiographic settings and exposure data acquired at Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007; comparison of these dose values with values reported in the literature; recommendation of a reference dose value for the thoracoabdominal babygram. Materials and Methods: The data from all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 1493 thoracoabdominal babygrams and 3632 abdomen X-rays of newborns and young infants. With the computer program PAeDOS, a specific dose reconstruction algorithm was developed. Results: the entrance dose values of thoracoabdominal babygrams and abdomen ...

2010-06-15

366

Radiation exposure of children in pediatric radiology, Pt. 8. Radiation doses during thoracoabdominal babygram and abdominal X-ray examination of the newborn and young infants  

International Nuclear Information System (INIS)

Purpose: Reconstruction of radiation doses for the thoracoabdominal babygram and the abdomen X-ray from radiographic settings and exposure data acquired at Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007; comparison of these dose values with values reported in the literature; recommendation of a reference dose value for the thoracoabdominal babygram. Materials and Methods: The data from all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 1493 thoracoabdominal babygrams and 3632 abdomen X-rays of newborns and young infants. With the computer program PAeDOS, a specific dose reconstruction algorithm was developed. Results: the entrance dose values of thoracoabdominal babygrams and abdomen X-rays in DvHK could ...

2010-06-01

367

Health-hazard evaluation report HETA 88-108-2146, Asarco New Market/Young Mines, Mascot, Tennessee  

Energy Technology Data Exchange (ETDEWEB)

In response to a request from the International Chemical Workers Union, Akron, Ohio, an investigation was made into possible hazardous working conditions at two American Smelting and Refining Company (SIC-1031) zinc mines (New Market and Young) in Mascot, Tennessee. Specifically, exposures to asbestos (1332214), silica (14808607), and diesel emissions were determined. At both mines overexposures were found to nitrogen-dioxide (10102440) (NO2) and coal-tar pitch volatiles. Twenty-four percent of the NO2 measurements taken were above the NIOSH recommended ceiling of 1 part per million (ppm), but none exceeded the Mine Safety and Health Administration's (MSHA) ceiling of 5ppm. Exposure to diesel particulates ranged from 0.24 to 1.06mg/cu m. None of the 52 respirable dust samples collected exceeded the calculated MSHA limits for free silica exposure. A medical evaluation was offered and 83 of the 400 current employees and one retired employee participated. Seven underground ...

1991-10-01

368

Fuji computed radiography (FCR) for the diagnosis of spinal disorders  

Energy Technology Data Exchange (ETDEWEB)

Since April, 1985, we have, in co-operation with the Fuji Film Co., Ltd., used Fuji Computed Radiography (FCR) in the diagnosis of spinal disorders. FCR is a new computed radiographic system which uses an energy-storage phosphorus panel called an ''Imaging Plate'' as an image sensor. The ''Imaging Plate'' can be used to obtain radiographs in exactly the same way as the screen-film combination used in conventional radiography; X-rays are exposed on the ''Imaging Plate'' instead of X-ray film in the conventional fashion, and then the ''Imaging Plate'' is calculated. The processed digital data from the scans is transformed into a picture by means of digital-to-analogue conversion. The pictures are always clear and beautiful. Plain films of the spine taken by FCR are even clearer, even in the ...

1987-04-01

369

Early detection of damage and analysis of damage development in metal structural components. Schaedigungsfrueherkennung und Schadensablauf bei metallischen Bauteilen  

Energy Technology Data Exchange (ETDEWEB)

The topics of these short lectures on the subject of cyclic stress were: Microstructural mechanisms of damage accumulation under a multistage cyclic stress until incipient cracking; influence of surface decarbonizing phenomena on the failure behaviour of steel construction parts subjected to cyclic stress; thermocyclic fatigue of pipe samples of austenitic steel 1.4436; studies on surface structuring, microstructure and fatigue in LCF area. The short lectures on effects of quasi-static and creep stress were: Shear fracture in AlMg alloys as a result of local plastic instability; study of formation and growth of pores for an early recognition of damage and the course of damage in heat-resistant steels under creep test; experimental and numeric studies of the infuence of the microstructure on the course of damage during shear fractures of steel; numerical modelling of ductile fractures on the basis of micromechanical models. Under the topic of tribological stress the following lectures ...

1989-01-01

370

Clinical Experiences With Onboard Imager KV Images for Linear Accelerator-Based Stereotactic Radiosurgery and Radiotherapy Setup  

International Nuclear Information System (INIS)

Purpose: To report our clinical experiences with on-board imager (OBI) kV image verification for cranial stereotactic radiosurgery (SRS) and radiotherapy (SRT) treatments. Methods and Materials: Between January 2007 and May 2008, 42 patients (57 lesions) were treated with SRS with head frame immobilization and 13 patients (14 lesions) were treated with SRT with face mask immobilization at our institution. No margin was added to the gross tumor for SRS patients, and a 3-mm three-dimensional margin was added to the gross tumor to create the planning target volume for SRT patients. After localizing the patient with stereotactic target positioner (TaPo), orthogonal kV images using OBI were taken and fused to planning digital reconstructed radiographs. Suggested couch shifts in vertical, longitudinal, and lateral directions were recorded. kV images were also taken immediately after treatment for 21 SRS patients and on a weekly basis for 6 SRT patients to assess any ...

2009-02-01

371

Bone age estimation and prediction of final height in patients with {beta}-thalassaemia major: a comparison between the two most common methods  

Energy Technology Data Exchange (ETDEWEB)

Thalassaemic patients are in need of frequent assessment of bone age because of growth failure and pubertal disorders. To compare the ''rapid'' Greulich and Pyle (G and P) method with the third edition of the Tanner and Whitehouse (TW3) method for determining skeletal maturity and predicting final height in thalassaemic patients. A total of 191 radiographs from 58 patients (28 male, 30 female) were retrospectively evaluated by two investigators, one for each method. In 47 radiographs from 15 patients having attained their adult height, predicted final height was calculated according to each method. The mean bone ages determined by both the G and P and TW3 methods were lower than mean chronological age, although the differences were not statistically significant (10.04 {+-} 3.69 years and 9.98 {+-} 3.39 years vs. 10.78 {+-} 3.96 years, respectively). Both methods had a tendency to over-estimate final height. ...

2007-12-15

372

Assessment of arterial tumor vascularity in small hepatocellular carcinoma. Comparison between color Doppler ultrasonography and radiographic imagings with contrast medium: dynamic CT, angiography, and CT hepatic arteriography  

Energy Technology Data Exchange (ETDEWEB)

Hepatocellular carcinoma (HCC) is characterized by tumor vascularization from the hepatic artery. The objective of our work was to compare color Doppler ultrasonography (CDU), including power Doppler ultrasonography (PDU) with radiographic imagings with contrast medium in regard to the detection of the arterial tumor vascularity of small hepatocellular carcinomas (HCC). We examined 42 small HCC lesions 2 cm or less in diameter in 37 patients for arterial tumor vascularity by conventional CDU, PDU, dynamic computed tomography (dCT), digital subtraction angiography (DSA), and CT hepatic arteriography (CTA). Color images were detected in 25 (59.5%) and 28 (66.7%) of the 42 lesions with conventional CDU and PDU, respectively, and tumor vascularity was detected in 26 (61.9%) by dCT, 23 (54.8%) by DSA, and 29 (69.0%) by CTA. Tumor vascularity could be detected in 51.9% by PDU and CTA, more than by conventional CDU, dCT, and DSA (44.4, 44.4, and 33.3%, respectively) in ...

2000-10-01

373

Correctness of multi-detector-row computed tomography for diagnosing mechanical prosthetic heart valve disorders using operative findings as a gold standard  

Energy Technology Data Exchange (ETDEWEB)

The purpose was to compare the findings of multi-detector computed tomography (MDCT) in prosthetic valve disorders using the operative findings as a gold standard. In a 3-year period, we prospectively enrolled 25 patients with 31 prosthetic heart valves. MDCT and transthoracic echocardiography (TTE) were done to evaluate pannus formation, prosthetic valve dysfunction, suture loosening (paravalvular leak) and pseudoaneurysm formation. Patients indicated for surgery received an operation within 1 week. The MDCT findings were compared with the operative findings. One patient with a Bjoerk-Shiley valve could not be evaluated by MDCT due to a severe beam-hardening artifact; thus, the exclusion rate for MDCT was 3.2% (1/31). Prosthetic valve disorders were suspected in 12 patients by either MDCT or TTE. Six patients received an operation that included three redo aortic valve replacements, two redo mitral ...

2009-04-15

374

Transpositions and malpositions of the great arteries  

International Nuclear Information System (INIS)

The transposition of the great arteries afters to an abnormal connection and relation of the great arteries in which the aorta arises from the morphologic right ventricle and the pulmonary artery from the morphologic left ventricle, while the malposition of the great arteries indicates an abnormal relationship between the great arteries in which the great arteries are not transposed across the ventricular septum but they are malposed, as is seen in double outlet right ventricle, double outlet left ventricle and single ventricles. Transpositions and malpositions of the great arteries are understood as a spectrum of malformation caused by abnormal conal development and can be included in the common category of 'conotruncal malpositions'. Authors analized 32 cases of transpositions and malpositions of the great arteries in which cineangiocardiographies were done at the Department of Radiology, Seoul National University ...

1980-12-01

375

Design of a new serotonin receptor 5-HT_1_A imaging agent based on "9"9"mTc  

International Nuclear Information System (INIS)

Serotonin is one of the neurotransmitters found in the brain and mediates brain functions. It is very well known that serotonin related brain abnormalities are exerted mainly via serotonin receptors in a similar manner to other neurotransmitters found in the brain. Recently, it has also been found that serotonin is involved in Alzheimer's disease either directly or indirectly by its actions on serotonergic neurons. To understand and treat the diseases caused by abnormalities in the serotonergic system in the brain, it is certain that its mechanism of function has to be well investigated. So far several 5-HT receptors and receptor subtypes have been well characterized. Moreover, serotonin agonists and antagonists acting on specific receptors are chemically synthesized and are now available for the prevention or treatment of serotonergic related diseases. In recent years, a great demand for developing neuroimaging agents has emerged for the ...

2004-07-01

376

`TUNDTEMP` - an advisory tool for the continuous steel casting process  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the major features of the advisory tool `TUNDTEMP`, developed to act as a decision support in the continuous steel casting process. `TUNDTEMP` provides a means to predict abnormal phenomena of temperature origin in the casting that may be difficult to foresee in practical situations. The heart of the system is a semi-empirical calculation model that yields an estimate of the evolution of the tundish temperature of the liquid steel on the basis of a few important casting factors. The user interface of the system is to a large extent based on the visual presentation of the simulated results. The system also contains an optional rule based mechanism that provides assistance in the result interpretation and, if wished, linguistically formulates action recommendations. A separate program has been built for the tuning of the calculation model and for maintenance of the system. At the end of the report, the different tuning parameters are listed and ...

1993-11-01

377

Vulnerability of biomarkers in the indigenous mollusk Anodonta cygnea to spontaneous pollution in a transition country  

British Library Electronic Table of Contents (United Kingdom)

The aim of this study was to estimate the sensitivity of biomarkers of stress and exposure in the bivalve mollusk Anodonta cygnea to spontaneous anthropogenic activities typical for the Western Ukraine. Three sites were examined during spring, summer and autumn: an agricultural site (A); the cooling pond of nuclear power plant (N) and a forestry close to the municipal water inlet (F). Common temporal changes of a battery of biochemical markers in the gills and hemolymph and morphological characteristics were shown by discriminant functional analysis. Classification trees built on the basis of the screened biomarkers demonstrated persistent peculiarities at each site: genotoxicity (nuclear abnormalities) at site A and endocrine disruption (high levels of vitellogenin-like proteins (Vtg-LP) ...

2010-01-01

378

Visualization of disturbed flow with spin-echo and cine MR imaging  

International Nuclear Information System (INIS)

MR images of steady and pulsatile disturbed flow, obtained with use of flow-compensated spin-echo (SE) and cine pulse sequences, revealed excellent flow visualization in three dimensions. Phantoms, built from molds of actual blood vessels, reproduced laminar, disturbed, or turbulent flow. Video recording (VR), performed under conditions equivalent to those of the MR experiments, showed separation zones identical to those seen on SE images. Pulsatile flow studies showed complex patterns of vortical flow on cine images and VR. Varying pulse sequence details changed contrast but not flow patterns. The validation of MR observations by VR has implications for clinical cine imaging and low abnormal signals observed on MR angiograms.

379

Urinary catecholamines in iron deficiency anemia: effects of environmental temperature  

Energy Technology Data Exchange (ETDEWEB)

Iron deficiency (ID) is associated with increased levels of norepinephrine (NE) in plasma and urine. They investigated the effect of 5-7 days exposure to three different environmental temperatures (10/sup 0/C, 24/sup 0/C, 30/sup 0/C) on urinary catecholamine levels to test the hypothesis that increased thermogenic activity is causal to this increased excretion in iron deficiency. Catecholamines were analyzed from acidified urine by HPLC-EC. The mean Hb in ID animals was 3.1 +/- .5 versus controls of 12.8 +/- 9. These data demonstrate that contrary to previous reports NE excretion is not normalized at a thermoneutral temperature and suggests a basic abnormality in peripheral SNS activity and NE metabolism in iron deficiency that is independent of environmental drive from thermogenesis.

1986-03-05

380

The use of peritoneal venous shunting for intractable neonatal ascites: a short case series  

British Library Electronic Table of Contents (United Kingdom)

Introduction: Intractable ascites in neonates has a varied etiology; and often, the cause is idiopathic. The management usually consists of observation, diuretics, paracentesis, albumin replacements, and self correction. However, in some cases, the above treatment remains unsuccessful. Results: We present 2 cases of intractable ascites causing metabolic abnormalities, severe protein and immunoglobulin loss, and respiratory compromise. Although the use of peritoneovenous shunts for intractable ascites has been reported previously, our cases differ in both technique and patient size. Our first patient is an ex-28-week premature, 1.4-kg infant with intractable ascites for which a peritoneal drain was initially placed. After 3 weeks and putting out nearly 300 mL of ascitic fluid daily, we plac...

2011-01-01

381

The bone mineral content and ultimate compressive strength of lumbar vertebrae.  

Science.gov (United States)

The bone mineral content of 109 lumbar vertebrae from 36 different subjects was determined by dual photon absorptiometry. The mean age of the subjects was 58.5 years (range, 31 to 79 years). The ultimate strength of the vertebral bodies was determined during axial compression. Bone mineral content and ultimate compressive strength were correlated (r = 0.86) and the strength was found to increase linearly with increasing amounts of bone mineral content. No differences in this correlation were found in the four vertebral levels (L-4) included in the study, but a difference in this correlation was found between specimens taken from male and female subjects. The results make it possible to estimate the strength of a vertebral body from the knowledge of its bone mineral content as determined by dual photon absorptiometry and provide a basis of estimations of normal and abnormal amounts of bone mineral content in the vertebrae of the lumbar spine. PMID:7361198

382

Steatohepatite non alcoolique chez une adolescente obese : une biopsie hepatique discutable  

British Library Electronic Table of Contents (United Kingdom)

The growing epidemic of juvenile obesity has prompted pediatricians to investigate obesity-related conditions in obese teenagers. We report a clinical case of severe hepatic fibrosis in an adolescent with severe and recent obesity. Because of elevated serum aminotransferase levels, abnormal hepatic ultrasonography and insulin resistance (impaired glucose tolerance), we suspected nonalcoholic steatohepatitis (NASH). Disease activity and fibrosis were confirmed on liver biopsy. Considering the risk of progression toward cirrhosis and its complications, and the pathological liver lesions, we started long-term medical monitoring and drug therapy to control weight loss. At present, although biopsy is the only validated way to establish the diagnosis of NASH, there is no consensus on its indicat...

2011-01-01

383

Somatic mutations detected by immunofluorescence and flow cytometry  

International Nuclear Information System (INIS)

We have at hand the tools for development of both a single amino acid substitution and a gene loss type assay for somatic cell mutations in human red cells. We are close to being able to assess the assays as possible means for screening the human population for individuals who may be a risk of acquiring abnormally high frequencies of mutant cells. The cause for such a high frequency of mutant cells could be a prior exposure of the individual to large amount of mutagen, or it could indicate a member of a vulnerable subpopulation that may have poor DNA repair systems. Either of these cases could well be an indication that the particular individual is at high risk that exposure to mutagens could lead to potential pathology. In the near future we expect to determine the reliability of the assays and to perform experiments to confirm the validity of flow cytometry in measuring real somatic mutagenic events that occur in vivo. (orig./AJ).

384

Short-term under/overreaction, anticipation or uncertainty avoidance? Evidence from India  

British Library Electronic Table of Contents (United Kingdom)

We examine the short-term price behaviour of three, size-conditioned Indian stock market indices, in response to informational shocks. A standard mean-adjusted returns model as well as the GJR-GARCH specification point towards underreaction to negative events in the medium and small capitalization indices. Also, the pre-event coefficients are generally negative and statistically significant, regardless of the sign of the shock, thus ruling out information leaks. We uncover a stable abnormal volatility pattern which increases monotonically a few days before the shock before suddenly decreasing in magnitude on the event day and beyond. We suggest uncertainty avoidance as a potential explanation of these features. The results are fairly robust across alternative event selection procedures, ti...

2011-01-01

385

Scoring of brain maturation in developmentally handicapped children with high-field MR imaging  

International Nuclear Information System (INIS)

A four-stage scoring system for brain maturation was established with MR imaging. First, gyration and myelination were analyzed in 50 anamnestically normal children (32-240 weeks postconceptional age). Subsequently 60 patients (same age range) with birth asphyxia, seizures, or developmental delays were evaluated analogously. T1- and T2-weighted images (500/30 and 3,000/120 [repetition time msec/echo time msec]) were obtained with a 2.35-T magnet in all children. Whereas gyration abnormalities were seen in some patients, all handicapped children presented with delayed myelination. In conclusion, prospective staging of brain development (gyration and myelination) is possible and is best obtained with T2-weighted images.

386

Radiation Protection Aspects of the Linac Coherent Light Source Front End  

Energy Technology Data Exchange (ETDEWEB)

The Front End Enclosure (FEE) of the Linac Coherent Light Source (LCLS) is a shielding housing located between the electron dump area and the first experimental hutch. The upstream part of the FEE hosts the commissioning diagnostics for the FEL beam. In the downstream part of the FEE, two sets of grazing incidence mirror and several collimators are used to direct the beam to one of the experimental stations and reduce the bremsstrahlung background and the hard component of the spontaneous radiation spectrum. This paper addresses the beam loss assumptions and radiation sources entering the FEE used for the design of the FEE shielding using the Monte-Carlo code FLUKA. The beam containment system prevents abnormal levels of radiations inside the FEE and ensures that the beam remains in its intended path is also described.

2010-08-26

387

Plasma Free Myristic Acid Proportion Is a Predictor of Nonalcoholic Steatohepatitis  

British Library Electronic Table of Contents (United Kingdom)

Background/Aims Serum free fatty acid (FFA) composition and abnormal fatty acid metabolism have been implicated in the pathogenesis of nonalcoholic steatohepatitis (NASH). Therefore, we determined if the serum FFA composition can provide accurate diagnosis of NASH. Methods We compared fasting serum FFA compositions in 20 patients with simple steatosis to those in 77 patients with NASH, including 65 patients with early-stage NASH. Results By univariate analysis, the proportions of serum free myristic acid (P?=?0.002) and palmitoleic acid (P?=?0.033) and the stearoyl CoA desaturase (SCD)-1 index (P?=?0.047) were significantly elevated in NASH patients in comparison to patients with simple steatosis. Only the serum free myristic acid proportion was significantly elevated in the early-stage NA...

2011-01-01

388

Online monitoring of steel casting processes using multivariate statistical technologies: From continuous to transitional operations  

British Library Electronic Table of Contents (United Kingdom)

This paper describes a state-of-the-art online monitoring system using multivariate statistical technologies for continuous steel casting process, which was commissioned at Dofasco's No. 2 caster to provide consistent indication of process health for caster's start-up, continuous production and transitional operations. The paper particularly focuses on development of a novel scheme to synchronize process trajectories for monitoring specific transitional operations such as equipment or steel product grade changes. The proposed scheme is demonstrated by several industrial examples with the results showing good detectability of various process abnormalities. With the aid of this fully integrated, innovative monitoring system, Dofasco has generated significant value through improved productivi...

2006-01-01

389

Nuclear magnetic resonance imaging of the abnormal live rat and correlations with tissue characteristics  

Energy Technology Data Exchange (ETDEWEB)

Nuclear magnetic resonance (NMR) images of live rats with sterile and pyogenic abscesses, hematomas, and various implanted and spontaneous neoplasms demonstrated good contrast differentiation between pathologic and surrounding normal tissues. This differentiation was maximal when both the T1 and T2 tissue relaxation times were used as criteria. Neoplasms have a broad range of T1 and T2 values and may be confused with abscesses or hematomas. Tissue rate constants (1/T1 and 1/T2) are mainly dependent on total water content, the exception being fat, which has a 1/T2 value much shorter than that expected on the basis of water content alone.

1981-10-01

390

Molecular pathology of tumor-initiating cells: Lessons from Philadelphia chromosome-positive leukemia  

British Library Electronic Table of Contents (United Kingdom)

Recent improvements in cell purification and transplantation techniques have contributed to the identification of cell populations known as tumor-initiating cells (TIC). This discovery has led to the -cancer stem cell hierarchy- concept, which holds that tumors are organized as a hierarchy of malignant tissues sustained by such TIC. However, this concept remains controversial. In this review, we examine recent advances in cancer stem cell research that have been generated from studies of Philadelphia (Ph) chromosome-positive leukemia. The abnormal Ph chromosome, which arises from a translocation creating the BCR-ABL1 fusion gene, is most commonly associated with chronic myelogenous leukemia (CML) and precursor B cell acute lymphoblastic leukemia (B-ALL). Examination of the pathophysiology ...

2011-01-01

391

Mechanisms involved in the antinociception of petroleum ether fraction from the EtOH extract of Chrysanthemum indicum in mice  

British Library Electronic Table of Contents (United Kingdom)

The petroleum ether fraction (PEF) from the EtOH extract of flowers and buds of Chrysanthemum indicum was evaluated on antinociception in mice using chemical and thermal models of nociception. PEF administered orally at doses of 188 and 376mg/kg produced significant inhibitions on chemical nociception induced by intraperitoneal acetic acid, subplantar formalin or capsaicin injections and on thermal nociception in the tail-flick test and the hot plate test. In the pentobarbital sodium-induced sleep time test and the open-field test, PEF neither enhanced the pentobarbital sodium-induced sleep time nor impaired the motor performance, indicating that the observed antinociception was unrelated to sedation or motor abnormality. In a measurement of core body temperature, PEF did not affect temper...

2011-01-01

392

Lithium abundances of southern F, G, and K dwarfs  

Energy Technology Data Exchange (ETDEWEB)

Observations are reported of the lithium feature (6708 A) in some bright southern stars, most of which are F, G, or K dwarfs. Three of these stars have been suggested as belonging to the Ursa Major Group. Two of these three have the large Li abundance and strong Ca II H and K emission expected of such young stars. The third potential Ursa Major Group member has little Li, but is also not a true kinematic member. No stars were found with abnormal (Li-6)/(Li-7) ratios, in accord with other recent analyses. Thus it appears that all stars have (Li-6)/(Li-7) near the solar/terrestrial value of 0.08. 31 references.

1985-01-01

393

Laparoscopic Transduodenal Ampullectomy for Benign Ampullary Tumors  

British Library Electronic Table of Contents (United Kingdom)

Abstract Introduction: Transduodenal ampullectomy (TDA) can be performed for benign and premalignant tumors of the ampulla of Vater (AOV) as an alternative to pancreaticoduodenectomy. However, the laparoscopic approach has rarely been attempted. In this report 2 cases of benign ampullary tumor that were treated by totally laparoscopic TDA. Patients and Methods: Case 1 was of a 75-year-old female who was admitted with left knee pain and underwent arthroscopic debridement. On postoperative day 6, she showed elevated levels of alkaline phosphatase, aspirate aminotransferase, alanine transaminase, and gamma-glutamyl transpeptidase, without any other laboratory test abnormality. She had no complaint of abdominal pain, and physical examinations were unremarkable. Computed tomography (CT), magnet...

2010-01-01

394

Endogenous expression of Hras(G12V) induces developmental defects and neoplasms with copy number imbalances of the oncogene.  

Science.gov (United States)

We developed mice with germline endogenous expression of oncogenic Hras to study effects on development and mechanisms of tumor initiation. They had high perinatal mortality, abnormal cranial dimensions, defective dental ameloblasts, and nasal septal deviation, consistent with some of the features of human Costello syndrome. These mice developed papillomas and angiosarcomas, which were associated with Hras(G12V) allelic imbalance and augmented Hras signaling. Endogenous expression of Hras(G12V) was also associated with a higher mutation rate in vivo. Tumor initiation by Hras(G12V) likely requires augmentation of signal output, which in papillomas and angiosarcomas is achieved via increased Hras-gene copy number, which may be favored by a higher mutation frequency in cells expressing the oncoprotein. PMID:19416908

2009-04-29

395

Emergency core cooling system  

International Nuclear Information System (INIS)

Purpose: To obtain stabilized operation by preventing over heat in emergency cooling pumps upon accidents of flow regulators. Constitution: A pressure suppression chamber pool and a pressure vessel are communicated to each other with a pipeway and the water in the suppression pool is charged by a charging pump to the pipeway. The pipeway is interposed with an emergency cooling pump so as to feed water in the pipeway to the pressure vessel and a water source and the emergency cooling pumps are connected by way of a closed pipeway. Further, the closed pipeway and the pipeway interposed with the charging pump are communicated to each other by way of a connecting pipeway, to which are interposed an instrument for detecting the increase in the temperature of the emergency cooling pumps due to abnormality in the closed pipe (such as troubles in flow regulators) and outputting control signals and an electrically actuated valve controlled by a control device. (Furukawa, ...

396

Effects of retinoic acid on maturation of immature mouse oocytes in the presence and absence of a granulosa cell co-culture system  

British Library Electronic Table of Contents (United Kingdom)

Purpose Evaluation of the all-trans retinoic acid (t-RA) effects on in vitro maturation (IVM) and in vitro fertilization (IVF) of immature mouse oocytes in the presence and absence of granulosa cell monolayer. Methods Denuded oocytes isolated from mice ovaries and matured in IVM medium alone (Control I), IVM medium in the presence of granulosa cells (Control II), IVM medium with t-RA (Experimental I) and IVM medium simultaneously with t-RA and granulosa cells (Experimental II). After 24?h, matured oocytes were fertilized in T6 medium and their development was followed until the blastocyst stage. Metaphase II oocytes ploidy were evaluated by chromosome counting. Results The t-RA group compared to the control groups showed no obvious abnormalities. Additionally maturation and embryo developm...

2011-01-01

397

Effect of Al and AlP on the microstructure of Mn-30 wt.%Si alloy  

Energy Technology Data Exchange (ETDEWEB)

Effect of Al and AlP particles on the microstructure of near eutectic Mn-Si alloy (Mn-30 wt.%Si) was studied by Electron Probe Micro-analyzer (EPMA) and Differential Scanning Calorimeter (DSC). Crystal lattice correspondence analyses show that both Al and AlP have good lattice matching coherence relationships with MnSi phase, and the addition of Al and AlP particles results in an abnormal eutectic structure, i.e. the eutectic constitution MnSi and Mn{sub 5}Si{sub 3} precipitate separately: MnSi precipitates firstly, and then the Mn{sub 5}Si{sub 3} phase.

2008-04-15

398

Dielectric abnormities in BaTi_0_._9(Ni_1_/_2W_1_/_2)_0_._1O_3 giant dielectric constant ceramics  

International Nuclear Information System (INIS)

BaTi_0_._9(Ni_1_/_2W_1_/_2)_0_._1O_3 ceramics were fabricated and their dielectric properties were investigated. With the sintering temperature increasing from 1250 to 1280 deg. C, the grain size abruptly increases from 1-2 to 20-40 #mu#m, accompanying significant changes in dielectric response. The samples with larger grains exhibit giant dielectric constant characteristics, which are considered to be mainly attributed to the domain boundary effect. The activation energies of the dielectric relaxation E_r_e_l_a_x=0.325 eV reveal the existence of microdomains in larger grains. The ac conductivity results also give the evidence of the domain boundary effect in the present ceramics.

2007-07-30

399

Diagnostic imaging in pregraduate integrated curricula; Radiologie in einem praegraduellen problembasiert-integrierten Medizincurriculum  

Energy Technology Data Exchange (ETDEWEB)

Pregraduate medical curricula are currently undergoing a reform process that is moving away from a traditional discipline-related structure and towards problem-based integrated forms of teaching. Imaging sciences, with their inherently technical advances, are specifically influenced by the effects of paradigm shifts in medical education. The teaching of diagnostic radiology should be based on the definition of three core competencies: in vivo visualization of normal and abnormal morphology and function, diagnostic reasoning, and interventional treatment. On the basis of these goals, adequate teaching methods and e-learning tools should be implemented by focusing on case-based teaching. Teaching materials used in the fields of normal anatomy, pathology, and clinical diagnosis may help diagnostic radiology to play a central role in modern pregraduate curricula. (orig.)

2007-11-15

400

Decreased dendritic spine density and abnormal spine morphology in Fyn knockout mice  

British Library Electronic Table of Contents (United Kingdom)

Fyn is a Src-family tyrosine kinase that affects long term potentiation (LTP), synapse formation, and learning and memory. Fyn is also implicated in dendritic spine formation both in vitro and in vivo. However, whether Fyn's regulation of dendritic spine formation is brain-region specific and age-dependent is unknown. In the present study, we systematically examined whether Fyn altered dendritic spine density and morphology in the cortex and hippocampus and if these effects were age-dependent. We found that Fyn knockout mice trended toward a decrease in dendritic spine density in cortical layers II/III, but not in the hippocampus, at 1month of age. Additionally, Fyn knockout mice had significantly decreased dendritic spine density in both the cortex and hippocampus at 3months and 1year, an...

2011-01-01

401

Cottonseed feeding delivers sufficient quantities of gossypol as a male deer contraceptive  

British Library Electronic Table of Contents (United Kingdom)

To define the quantitative and qualitative effects of gossypol (GP) on deer (Cervus elaphus) semen, the animals were fed cottonseed (CS). Adult stags each received 350?g of CS for 109?days. Animals received 15?mg of gossypol per kilogram body weight per day. Quantitative and qualitative parameters of experimental ejaculates (n?=?182) were compared to ejaculates (n?=?571) of control animals (n?=?5) collected during three previous natural reproductive seasons. Ejaculate fractions were evaluated by classical methods used in domestic animals. In this paper, we show that mature male deer fed CS exhibited morphological changes and decreased motility of spermatozoa and abnormalities in spermatogenesis. Radioimmunoassay measured concentrations of various steroid hormones (T-testosterone, A4-andros...

2008-01-01

402

Containment closure time following loss of cooling under shutdown conditions of YGN units 3 and 4  

Energy Technology Data Exchange (ETDEWEB)

The YGN Units 3 and 4 plant conditions during shutdown operation were reviewed to identify the possible event scenarios following the loss of shutdown cooling. The thermal hydraulic analyses were performed for the five cases of RCS configurations under the worst event scenario, unavailable secondary cooling and no RCS inventory makeup, using the RELAP5/MOD3.2 code to investigate the plant behavior. From the analyses results, times to boil, times to core uncovery and times to core heat up were estimated to determine the containment closure time to prevent the uncontrolled release of fission products to atmosphere. These data provide useful information to the abnormal procedure to cope with the event. 6 refs., 7 figs., 2 tabs. (Author)

1998-12-31

403

Chain radiation-chemical cross-linking of polyethylene under high pressures. [Gamma radiation  

Energy Technology Data Exchange (ETDEWEB)

Regularities in the radiation cross-linking of low-density polyethylene under various conditions of ..gamma..-irradiation were studied. It is shown that at the 0.5 GPa pressure and 450 K the gel formation is initiated at doses of about 1 kGy, i.e. at doses 10 times as low as compared to normal conditions. Abnormally high rate of radiation cross-linking at high temperature and high pressure is an evidence of changes in the mechanism of polyethylene, radiation cross-linking, i.e. of the process transition from nonchain to chain conditions. Decrease in the potential barriers of macroradical reactions with macromolecules is the most probable reason of change in the polymer cross-linking nature.

1984-01-01

404

Arterial stiffness is associated with low thigh muscle mass in middle-aged to elderly men  

British Library Electronic Table of Contents (United Kingdom)

Objective: Sarcopenia of legs is an important cause of physical dysfunctions, frailty and dependence. Many predisposing and underlying mechanisms of sarcopenia, including age, sedentary life style, oxidative stress, insulin resistance, and low testosterone levels, are also known to be related to atherosclerosis, which is another leading cause of morbidity and mortality in elderly subjects. In this study, we investigated our hypothesis that sarcopenia and atherosclerosis are associated with each other to facilitate mutual abnormalities. Methods: Study was performed in apparently healthy 496 middle-aged to elderly persons recruited consecutively among the visitors to the medical check-up program, Anti-Aging Doc, in a University hospital, from March 2006 to December 2007. Mid-thigh muscle cro...

2010-01-01

405

Anatomical Description of the Female Reproductive Organ and Radiation Induced Histological changes of Ovary of Melon fly, Bactrocera cucurbitae (Coq.) (Diptera: Tephritidae)  

International Nuclear Information System (INIS)

Application of gamma radiation as a physical method of disinfestations against melon flies was recognized as a potential quarantine treatment. At 50 Gy, oocytes showed degeneration one day after treatment whereas seven-day-old oocytes did not differ greatly in appearance from control groups. Abnormal enlargement of trophocyte cells and vacuolization of oocytes occurred predominantly following the treatment with 100 and 150 Gy. One day after treatment with 150 Gy trophocytes underwent hypertrophy and hyperplasia. Irradiation at 100 and 150 Gy reduced the fertility to almost zero percent in the female melon flies.(authors)

2006-06-01

406

Amphiphysin (Amph) maps to the proximal region of mouse chromosome 13  

Energy Technology Data Exchange (ETDEWEB)

Amphiphysin is a protein concentrated in neuronal synapses and peripherally associated with neurotransmitter vesicles. It is expressed in many neurons of the central and peripheral nervous systems, in the adrenal medulla, in the anterior and posterior pituitary, in cell lines of the endocrine pancreas, and in spermatocytes. Its subcellular localization and tissue distribution indicate a potential involvement in mechanisms of regulated exocytosis. A role in the dynamic organization of the membrane-associated cytoskeleton is suggested by structural homology to the products of two yeast genes, RVS161 and RVS167, whose mutation results in an abnormal actin distribution, disturbs budding morphology, and impairs cell entry into stationary phase. Limited stretches of sequence similarity, including an SH3 domain, are also shared with other actin-binding proteins. Amphiphysin is the dominant autoantigen in paraneoplastic Stiff-Man syndrome, a neurological autoimmune ...

1995-07-20

407

Abnormal structure or function of the amygdala is a common component of neurodevelopmental disorders  

British Library Electronic Table of Contents (United Kingdom)

The amygdala, perhaps more than any other brain region, has been implicated in numerous neuropsychiatric and neurodevelopmental disorders. It is part of a system initially evolved to detect dangers in the environment and modulate subsequent responses, which can profoundly influence human behavior. If its threshold is set too low, normally benign aspects of the environment are perceived as dangers, interactions are limited, and anxiety may arise. If set too high, risk taking increases and inappropriate sociality may occur. Given that many neurodevelopmental disorders involve too little or too much anxiety or too little of too much social interaction, it is not surprising that the amygdala has been implicated in many of them. In this chapter, we begin by providing a brief overview of the phy...

2011-01-01

408

Role of Spiral and Multislice Computed Tomography in the evaluation of traumatic and spontaneous oesophageal perforation. Our experience; Ruolo della Tomografia Computerizzata Spirale e Multistrato nello studio delle lesioni traumatiche e spontanee dell'esofago: nostra esperienza  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To assess the role of CT in the evaluation of traumatic and spontaneous oesophageal perforation. Materials and methods: From March 2001 to May 2003, we studied 12 patients (7 males and 5 females; age range: 25-66 years, mean age: 43.5 years) with suspected oesophageal perforation due to motor-vehicle accidents (4 cases), stab wound (one case), post-intubation (2 cases), foreign body ingestion (2 cases) and spontaneous (3 cases). Five patients underwent standard chest and cervical radiography; two patients with suspected foreign body ingestion also underwent a gastrografin swallow study; all of the 12 patients underwent CT of the neck, chest and abdomen before and after intravenous, and in four cases oral, administration of contrast material. Results: In 5 patients with cervical, thoracic and abdominal trauma, the CT examination showed the presence of pleuroparenchymal injury (pneumothorax, pleural effusion and subcutaneous emphysema) as well as findings ...

2005-03-01

409

Tunnel Sensors Equipment on Environmental Expert  

Wastenet

... Tunnel Sensors Equipment on Environmental Expert Find and compare a variety of tunnel sensors equipment on the world's largest environmental industry portal. View ...

410

The ultrastructure of conjunctival melanocytic tumors.  

UK PubMed Central (United Kingdom)

The ultrastructure of conjunctival melanocytic lesions in 49 patients was evaluated to find significant differences between benign and malignant cells. The patients studied included 9 with benign epithelial...Full Text Available

1984-01-01

411

The Spectrum of Fundus Autofluorescence Findings in Birdshot Chorioretinopathy  

UK PubMed Central (United Kingdom)

Objective. To describe the diverse patterns observed with the use of autofluorescence fundus photography (FAF) in patients with Birdshot chorioretinopathy (BSCR). Methods....Full Text Available

2009-01-01

412

Tarlov Cyst and Infertility  

UK PubMed Central (United Kingdom)

Background/Objective:Tarlov cysts or spinal perineurial cysts are uncommon lesions. These are mostly incidental findings on magnetic resonance imaging or myelograms. The...Full Text Available

2009-04-01

413

TREE-MENDOUS TIMBER EVALUATION  

Science.gov (United States)

depth timber industry experience with state-of-the-art ... difficult to find high-value pockets of timber (also known as timber stands ) to supply his ...

414

Sacral haemangioma as a cause of coccydynia  

International Nuclear Information System (INIS)

We report a 55-year-old woman with coccydynia due to a sacral mass. The histological diagnosis was haemangioma. The MRI findings and the unusual location of this lesion are discussed. (orig.)

1998-08-01

415

SOFIA - Woody Debris in the Mangrove Forests of South Florida  

Science.gov (United States)

although additional research is needed to corroborate such findings. Key words: Avicennia germinans; disturbance; downed wood; Everglades National Park; Hurricane Andrew;...

2011-09-04

416

Principles of antibody therapy.  

UK PubMed Central (United Kingdom)

The success of monoclonal antibodies in clinical practice is dependent on good design. Finding a suitable target is the most important part as other properties of the antibody can be altered by genetic...Full Text Available

1992-12-05

417

Periodontal disease and spontaneous preterm birth: a case control study  

UK PubMed Central (United Kingdom)

BackgroundSeveral studies have suggested an association between periodontal disease and prematurity but this finding has not been consistently observed.MethodsCase...Full Text Available

418

Optical Coherence Tomography Findings in Idiopathic Macular Holes  

UK PubMed Central (United Kingdom)

Purpose. To describe the characteristics of idiopathic macular holes (MH) on optical coherence tomography (OCT) and correlate OCT with clinical assessment. Design....Full Text Available

2011-01-01

419

Non-opaque soft tissue foreign body: sonographic findings  

UK PubMed Central (United Kingdom)

BackgroundSoft tissue foreign bodies are a common cause of orthopedic consultation in emergency departments. It is difficult to confirm their existence because conventional radiology...Full Text Available

420

Neuroradiologic and Neurophysiologic Findings of Neuralgic Amyotrophy  

UK PubMed Central (United Kingdom)

ObjectiveNeuralgic amyotrophy (NA) is a distinct clinical syndrome that is characterized by the acute onset of shoulder and arm pain, weakness, and sensory loss. The purpose of this...Full Text Available

2010-11-01

421

NASA Orbiter Finds Possible Cave Skylights on Mars - Solar System ...  

Science.gov (United States)

Sep 21, 2007... at night," said Glen Cushing of the U.S. Geological Survey's Astrogeology Team and of Northern Arizona University, Flagstaff, Ariz. ...

422

NAME=\\  

Wastenet

... Waste Collection Systems Products and Equipment Find and compare a variety of waste collection systems products and equipment on the world's largest environmental industry portal. View product ...

423

NAME=\\  

Wastenet

...Air Quality Monitoring Networks Products and Equipment Find and compare a variety of air quality monitoring networks products and equipment on the world's largest environmental industry portal. ...

424

Multifunctional aerogel thermal protection systems for hypersonic ...  

Science.gov (United States)

Sep 18, 2007 ... Lightweight structural aerogels would find applications as a component of composite sandwich panels that are both lightweight and insulating ...

425

Mental Health and Traumatic Events  

Science.gov (United States)

News Jobs Grants/Funding Families Prevention Diseases Regulations Preparedness Mental Health and Traumatic Events Find Local Mental Health Services Information for: Parents and...

2011-08-27

426

Magnetic resonance imaging in human lymphodemas  

International Nuclear Information System (INIS)

The MRI's of 16 patients with either primary or secondary lymphatic disorders are evluated and the findings are compared to those from lymphangioscintigraphy or surgery. (author).

1989-09-02

427

INVESTIGATION OF THE CORROSION RESISTANCE OF BS ...  

Science.gov (United States)

... 1. IE1O and IM'15 exposed to field corrosion tests at five sites for periods of 12 and 24 months confirm previous findings. ...

1953-12-01

428

Gravity_on_Spinning_Cylinders - NASA Quest  

Science.gov (United States)

You can find a discussion of time travel and Tipler's cylinder at this site: http://www.star-names.freeserve.co.uk/travel.htm ...

429

Gold Mining in the Peruvian Amazon: Global Prices, Deforestation ...  

Science.gov (United States)

Sep 1, 2011 ... We find that since 2003, recent mining deforestation in Madre de Dios, Peru is increasing nonlinearly alongside a constant annual rate of ...

430

Geothermal Energy Equipment in Finland on Environmental Expert  

Wastenet

... Geothermal Energy Equipment in Finland on Environmental Expert Find and compare a variety of geothermal energy equipment in finland on the world's largest environmental ...

431

Geothermal Energy Equipment in Belgium on Environmental Expert  

Wastenet

... Geothermal Energy Equipment in Belgium on Environmental Expert Find and compare a variety of geothermal energy equipment in belgium on the world's largest environmental ...

432

Fuel Cell Technologies Equipment on Environmental Expert  

Wastenet

... Fuel Cell Technologies Equipment on Environmental Expert Find and compare a variety of fuel cell technologies equipment on the world's largest environmental industry portal. View ...

433

Finding the Demons in Our Midst: Utilizing DOD ISR Assets to ...  

Science.gov (United States)

... six major international terrorist attacks are considered ... Tanzania and Kenya), the USS COLE bombing of ... the September 11th terrorist attack on the ...

2002-02-04

434

Female urethral syndrome. A female prostatitis?  

UK PubMed Central (United Kingdom)

The cause of the female urethral syndrome has previously been obscure, as it has been associated by definition with a lack of objective findings but a plethora of subjective complaints of retropubic...Full Text Available

1996-05-01

435

Corrosive Fumes Equipment on Environmental Expert  

Wastenet

... Corrosive Fumes Equipment on Environmental Expert Find and compare a variety of corrosive fumes equipment on the world's largest environmental industry portal. View ...

436

Corrosion Inhibitors Equipment on Environmental Expert  

Wastenet

... Corrosion Inhibitors Equipment on Environmental Expert Find and compare a variety of corrosion inhibitors equipment on the world's largest environmental industry portal. View ...

437

Comparing healthcare outcomes.  

UK PubMed Central (United Kingdom)

Governments are increasingly concerned to compare the quality and effectiveness of healthcare interventions but find this a complex matter. Crude hospital statistics can be dangerously misleading and...Full Text Available

1994-06-04

438

Biogas Analyzers Equipment on Environmental Expert  

Wastenet

... Biogas Analyzers Equipment on Environmental Expert Find and compare a variety of biogas analyzers equipment on the world's largest environmental industry portal. View ...

439

Advances in Imaging of Vertebral and Spinal Cord Injury  

UK PubMed Central (United Kingdom)

Background/Objectives:Imaging technology is an important part of the diagnosis and management of spinal trauma. Indications and findings in post-traumatic imaging of the vertebral...Full Text Available

2010-04-01

440

X-ray phase imaging using a X-ray tube with a small focal spot. Improvement of image quality in mammography  

International Nuclear Information System (INIS)

Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and the screen-film system was determined for phase imaging of mammography. In order to investigate a potential for medical application of this method, we conducted evaluation of the images of the American Collage ...

2002-03-01

441

The Use of Particulate Bone Grafts From the Mandible for Maxillary Sinus Floor Augmentation Before Placement of Surface-Modified Implants: Results From Bone Grafting to Delivery of the Final Fixed Prosthesis  

British Library Electronic Table of Contents (United Kingdom)

PurposeThis prospective study followed 61 patients who were partially dentulous and considered to have insufficient bone volume for routine implant treatment and consequently underwent sinus inlay bone grafting.Patients and MethodsThe patients were treated with maxillary sinus floor augmentation with particulated autogenous bone from the mandibular ramus/corpus. After a healing period, dental implants (n = 180) were installed.ResultsRadiographic examination revealed average residual vertical bone heights of 6.5 mm in the first premolar region, 3.8 mm in the second premolar region, 3.5 mm in the first molar region, and 2.6 mm in the second molar region. The average implant lengths were 12 mm in the first premolar region and 11 mm in the second premolar, first, and second molar regions. All ...

2008-01-01

442

System suitable for use in neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

A system for real-time neutron radiography of moving objects is described. It comprise a source adapted to generate a continuous uninterrupted series of neutron pulses. Each pulse has a predetermined peak power and duration compatible with the framing times of a real-time video imaging system. A transporter moves an object to be examined to bring sequentially position selected portions of the object in the path of the pulses. Where the object itself has moving components, pulses are sequentially incident on the object. According to any dissimilarities, the object will alter the intensity of the neutrons passing therethrough. In order to record separately the changes in the neutron intensity, for each pulse, an imager is positioned to receive the neutron beam pulses which have been altered by their passage through the object and produce images indicating intensity alterations. A refrigerated beryllium filter can be used to effectively eliminate thermal neutrons from the pulses and ...

1990-02-07

443

System suitable for use in neutron radiography  

International Nuclear Information System (INIS)

A system for real-time neutron radiography of moving objects is described. It comprise a source adapted to generate a continuous uninterrupted series of neutron pulses. Each pulse has a predetermined peak power and duration compatible with the framing times of a real-time video imaging system. A transporter moves an object to be examined to bring sequentially position selected portions of the object in the path of the pulses. Where the object itself has moving components, pulses are sequentially incident on the object. According to any dissimilarities, the object will alter the intensity of the neutrons passing therethrough. In order to record separately the changes in the neutron intensity, for each pulse, an imager is positioned to receive the neutron beam pulses which have been altered by their passage through the object and produce images indicating intensity alterations. A refrigerated beryllium filter can be used to effectively eliminate thermal neutrons from the pulses and ...

1988-07-20

444

Study of chest portable radiography using computed radiography. Removal effect of X-ray scatter by a copper plate  

Energy Technology Data Exchange (ETDEWEB)

When chest radiographs are obtained using an anti-scatter grid in a mobile x-ray unit by Fuji Computed Radiography (FCR), right lung densities may differ from left lung densities owing to misalignment caused by an oblique x-ray beam. Such misalignment is considered to be caused by factors such as the shape of the bed and angle of the x-ray tube. Misalignment is especially frequent when exposure is carried out in the sitting position. Although a low-ratio grid has been reported to offer improvement, the misalignment is not completely eliminated. Therefore, we used a copper plate without a lattice feature instead of grid, and examined the results. The copper plate was found to have the ability of a grid to eliminate radiation scatter, and, furthermore, to offer the physical capabilities of a grid as determined by Carlin's new grid assessment method. Image quality was demonstrated through contrast manipulation to be equal to that obtained by grid use. ...

2001-04-01

445

Study of chest portable radiography using computed radiography. Removal effect of X-ray scatter by a copper plate  

International Nuclear Information System (INIS)

When chest radiographs are obtained using an anti-scatter grid in a mobile x-ray unit by Fuji Computed Radiography (FCR), right lung densities may differ from left lung densities owing to misalignment caused by an oblique x-ray beam. Such misalignment is considered to be caused by factors such as the shape of the bed and angle of the x-ray tube. Misalignment is especially frequent when exposure is carried out in the sitting position. Although a low-ratio grid has been reported to offer improvement, the misalignment is not completely eliminated. Therefore, we used a copper plate without a lattice feature instead of grid, and examined the results. The copper plate was found to have the ability of a grid to eliminate radiation scatter, and, furthermore, to offer the physical capabilities of a grid as determined by Carlin's new grid assessment method. Image quality was demonstrated through contrast manipulation to be equal to that obtained by grid use. Further, optimal ...

2001-04-01

446

Root canal preparation with the NiTi systems K3, Mtwo and ProTaper  

British Library Electronic Table of Contents (United Kingdom)

Abstract The aim of this paper was to examine the result of rotary root canal preparation with the nickel-titanium (NiTi) systems K3, ProTaper and Mtwo. One hundred and fifty curved artificial root canals and 60 mesial canals of human mandibular molars were selected. In the group of curved artificial canals, all canals were prepared to size 35/0.04 taper with the three systems. In the group of human mandibular molars, the teeth with mature root canals were radiographed with silver points inserted in bucco-lingual and in mesio-distal positions. In the artificial root group, one K3 instrument separated. Mtwo (20%) showed significantly (P = 0.003) less zips than K3 (46.9%) or ProTaper (50%). There were no significant differences in ledge and elbow formation. K3 and Mtwo had the lowest percent...

2007-01-01

447

Real-time neutron radiography system performance - Measurements and methods  

Energy Technology Data Exchange (ETDEWEB)

The University of Virginia's real-time neutron radiography facility was characterized by measurement of the total neutron flux, gold/cadmium ratio, neutron/gamma ratio, and the effective collimar length-to-aperture diameter (L/D) ratio. The real-time neutron imaging system and collimator were further characterized by measuring the modulation transfer function (MTF) of the system. The collimator effectiveness was measured by using the MTF to determine the ''unparallelism'' of the neutron beam. The computer-based image processing system allowed rapid calculation of the MTF and the collimator effectiveness. The results of these measurements, using no collimator and a simple tube collimator, demonstrated the method's ability to determine the effective L/D ratio. The MTF measurement scheme provided a fast, reliable, and reproducible means of monitoring any changes in the real-time system, including both the neutron beam and the ...

1988-09-01

448

Real-time neutron radiography system performance - Measurements and methods  

International Nuclear Information System (INIS)

The University of Virginia's real-time neutron radiography facility was characterized by measurement of the total neutron flux, gold/cadmium ratio, neutron/gamma ratio, and the effective collimar length-to-aperture diameter (L/D) ratio. The real-time neutron imaging system and collimator were further characterized by measuring the modulation transfer function (MTF) of the system. The collimator effectiveness was measured by using the MTF to determine the ''unparallelism'' of the neutron beam. The computer-based image processing system allowed rapid calculation of the MTF and the collimator effectiveness. The results of these measurements, using no collimator and a simple tube collimator, demonstrated the method's ability to determine the effective L/D ratio. The MTF measurement scheme provided a fast, reliable, and reproducible means of monitoring any changes in the real-time system, including both the neutron beam and the electronic components. This paper describes the methods and ...

1988-01-01

449

Radiographic in-situ measurements of intrinsic stresses between 750 C and 900 C. Optimisation of the measuring system; Roentgenographische In-situ-Messungen der Eigenspannungen zwischen 750 C und 900 C. Optimierung der Messeinrichtung  

Energy Technology Data Exchange (ETDEWEB)

One aspect of the research program SFB 570 'Distortion engineering' is the in situ X-Ray diffraction analysis of phases and residual stresses during complete heat treatment cycles. These investigations result in experimental evidence available for the extensive computations. The optimisation of the instrumentation will be reported. A surface decarburisation of samples made from the ball bearing steel 100Cr6 could be avoided for a temperature range from 800 to 900 C and a holding time of one hour by a combination of evacuate the furnace and using a certain nitrogen flow as protective gas. At lower temperatures small amounts of ferrite caused by an increased diffusion rate of carbon lead again to a surface decarburisation up to a depth of 2 {mu}m. It was proved that with an evacuation of the X-Ray beam path at constant power of the X-Ray source the intensity of diffraction lines could be increased by more than a factor of 4. The use of nitrogen as protective gas instead ...

2007-07-01

450

Quantitative bone scintigraphy in renal osteodystrophy  

International Nuclear Information System (INIS)

The need for noninvasive sensitive techniques for the diagnosis and follow-up of metabolic bone disease in dialysis patients has stimulated the author's interest in the efficacy of more detailed quantitative bone scintigraphy. Using hemodialysis to reduce elevated soft-tissue activity at scintigraphy, an attempt was made to assess the diagnostic sensitivity of quantitative bone scintigraphy as compared to qualitative bone scintigraphic, biochemical, radiographic and bone histologic studies. The second aim of these studies was to determine if one of the two major components of renal osteodystrophy is a major determinant for skeletal radiotracer uptake. The clinical observations on the efficacy and possible specificity of quantitative bone scintigraphy in the diagnosis and follow-up during treatment of renal osteodystrophy are presented briefly in this chapter. Thus, the use of scintigraphy for the routine detection and follow-up of renal osteodystrophy in dialysis ...

451

Prognostic precision in postoperative /sup 99m/Tc-MDP scintimetry after femoral neck fracture  

Energy Technology Data Exchange (ETDEWEB)

A 2-year follow-up regarding healing complications, such as redisplacement, nonunion, and segmental collapse of the femoral head, was performed in 306 patients operated on for femoral neck fracture and examined with /sup 99m/Technetium-MDP scintimetry within 2 weeks postoperatively. Scintimetric evaluation was performed by selecting regions of interest over the femoral head on the fracture side and the intact side and by comparing the uptake. A femoral head ratio fractured/intact side thus was obtained. Of 199 patients with an intact femoral head uptake (ratio less than or equal to 1.0), 181 showed no signs of healing complications at 2 years, whereas 18 had developed healing complications. Of 107 cases with a deficient femoral-head uptake (ratio < 1.0), 96 had developed healing complications within 2 years from the operation, while 11 cases had no signs of radiographic complications. We conclude that /sup 99m/Tc-MDP scintimetry performed within 2 weeks from ...

1987-01-01

452

Prognostic precision in postoperative "9"9"mTc-MDP scintimetry after femoral neck fracture  

International Nuclear Information System (INIS)

A 2-year follow-up regarding healing complications, such as redisplacement, nonunion, and segmental collapse of the femoral head, was performed in 306 patients operated on for femoral neck fracture and examined with "9"9"mTechnetium-MDP scintimetry within 2 weeks postoperatively. Scintimetric evaluation was performed by selecting regions of interest over the femoral head on the fracture side and the intact side and by comparing the uptake. A femoral head ratio fractured/intact side thus was obtained. Of 199 patients with an intact femoral head uptake (ratio #<=# 1.0), 181 showed no signs of healing complications at 2 years, whereas 18 had developed healing complications. Of 107 cases with a deficient femoral-head uptake (ratio < 1.0), 96 had developed healing complications within 2 years from the operation, while 11 cases had no signs of radiographic complications. We conclude that "9"9"mTc-MDP scintimetry performed within 2 weeks from femoral neck fracture ...

453

Physics of electron beam therapy  

International Nuclear Information System (INIS)

A book has been written to introduce the physical aspects of the radiotherapy electron beam by presenting a summary of the developments in this field. The first chapter is a brief introduction to the technology of medical accelerators with emphasis on the electron beam production facilities. Chapter 2 describes the interaction processes at the atomic level once the electron beam enters the medium. Chapter 3 is concerned with the various properties of the electron beam purely from the clinical point of view. The electron beam algorithms and models for distribution calculations are covered in Chapter 4 with inclusion of age diffusion and multiple scattering approaches. The factors affecting the beam distribution in a patient, with inhomogeneities, surface irregularities, backscattering etc. are discussed in Chapter 5. The last two chapters are devoted to electron beam dosimetry including various dosimetric methods, specification and measurement of beam energy, radiation output and beam ...

454

Phantom and animal imaging studies using PLS synchrotron X-rays  

CERN Document Server

Ultra-high resolution radiographs can be obtained using synchrotron X-rays. A collaboration team consisting of K-JIST, POSTECH and YUMC has recently commissioned a new beamline (5C1) at Pohang Light Source (PLS) in Korea for medical applications using phase contrast radiology. Relatively simple image acquisition systems were set up on 5C1 beamline, and imaging studies were performed for resolution test patterns, mammographic phantom, and animals. Resolution test patterns and mammographic phantom images showed much better image resolution and quality with the 5C1 imaging system than the mammography system. Both fish and mouse images with 5C1 imaging system also showed much better image resolution with great details of organs and anatomy compared to those obtained with a conventional mammography system. A simple and inexpensive ultra-high resolution imaging system on 5C1 beamline was successfully implemented. The authors were able to acquire ultra-high resolution ...

2001-01-01

455

On the determination of the dose-area product during X-ray examinations  

International Nuclear Information System (INIS)

Despite its great usefulness in the performance of the recording procedures prescribed by the X-Ray Ordinance the dose-area product is much less frequently measured for X-ray exposures than during fluorscopic examinations. The great multitude of measuring units, mainly on account of different scales of the measuring equipments themselves, is a cause of uncertainty in clinical routine and should be eliminated as far as the circumstances would permit. As the determination of the organ dose is relevant only in very few cases and does not necessarily require previous measurements of the dose-area product, these are of limited practical value in the assessment of individual radiation exposures during radiographic examinations. The measurements may, however, be very helpful in determinations of the radiation dose to the total population, if the future retrievability of the values obtained is ensured. In addition to some measuring values showing past and present ...

456

Neutron radiography with the cyclotron, 4  

International Nuclear Information System (INIS)

A real-time neutron radiography system was installed at the neutron radiography facility of Sumitomo Heavy Industries where a sub-compact cyclotron is used as a neutron generator and nominal neutron flux was observed as 1.1 x 10"6 n/cm"2/sec. Preliminary tests were made for various kinds of such components as collimators, scintillators, cameras and lenses and the system was chosen to give the highest quality images. Especially for the scintillator screen, screening tests were carried out for compounds of LiF/ZnS(Ag) and Gd_2O_3/ZnS(Ag) by radiographic film method. The neutron radiography image was converted to fluorescent images by means of the converter and observed by a SIT type TV camera. The video signal was directly displayed on a CRT or after processed with digital image processing devices. The characteristics of this system as for the resultant resolution are presented together with some actual application to dynamical fluid motion of real-time neutron ...

1986-01-01

457

Imaging Ewing's sarcoma  

International Nuclear Information System (INIS)

Ewing's sarcoma is a highly malignant neoplasm of the bone whose origin is still uncertain. A strong relationship exists between Ewing's sarcoma and tumors of neural origin (Ewing family of tumors). Ewing's sarcoma must be distinguished from other round-cell tumors like lymphoma and neuroblastoma and also must be differentiated from osteogenic sarcomas. On plain radiographs, Ewing's sarcoma appears as a lytic or mixed lytic-sclerotic, rarely as predominantly sclerotic lesion with margins Lodwick grade III. It is located primarily in the diaphyseal and metadiaphyseal regions of the long bones of the lower extremities. A large soft tissue tumor is usually present. Magnetic resonance imaging is the imaging modality of choice to evaluate the extent of the primary lesion, to monitor the response to neoadjuvant chemotherapy and to follow up non-resected Ewing's sarcomas. Bone scintigraphy is necessary to detect skeletal metastasis, and "2"0"1thallium scanning has been ...

1998-06-01

458

Femoral head viability following hip fracture. Prognostic role of radionuclide bone imaging  

Energy Technology Data Exchange (ETDEWEB)

A retrospective study was made of all radionuclide (RN) bone images performed at our institution over a two-year period to evaluate femoral head viability after nonpathologic fracture of the femoral neck. Twelve patients had avascular femoral heads during the perioperative period, of which nine had adequate follow-up. Seven of these nine patients had follow-up bone images. Revascularization occurred in four patients, while three had persistent absence of femoral head uptake. With clinical follow-up ranging from four to 29 months (median: 14 months), only two of these nine patients developed clinical or radiographic evidence of osteonecrosis. RN bone imaging performed in the perioperative period does not reliably predict the development of post-traumatic osteonecrosis of the femoral head and, at present, should not be used to determine prospectively method of treatment of femoral neck fracture.

1985-03-01

459

Femoral head viability following hip fracture. Prognostic role of radionuclide bone imaging  

International Nuclear Information System (INIS)

A retrospective study was made of all radionuclide (RN) bone images performed at our institution over a two-year period to evaluate femoral head viability after nonpathologic fracture of the femoral neck. Twelve patients had avascular femoral heads during the perioperative period, of which nine had adequate follow-up. Seven of these nine patients had follow-up bone images. Revascularization occurred in four patients, while three had persistent absence of femoral head uptake. With clinical follow-up ranging from four to 29 months (median: 14 months), only two of these nine patients developed clinical or radiographic evidence of osteonecrosis. RN bone imaging performed in the perioperative period does not reliably predict the development of post-traumatic osteonecrosis of the femoral head and, at present, should not be used to determine prospectively method of treatment of femoral neck fracture.

460

Ewing's sarcoma. Evaluation of radiotherapy and control of the primary tumor  

International Nuclear Information System (INIS)

From 1964 to 1973 at the Institute of Oncology and Radiobiology, Havana City, 18 clinical histories were studied, all of them from patients with Erwing's sarcoma, histologically diagnosticated by biopsy. Age, sex, race, traumatism background, hemogram disturbances, radiographic signs, primary tumor localization, and early treatment, were exposed. Early treatment in 14(83%) patients as radiotherapy. Local recurrence or metastasis was presented in 10(55,5%) patients during the two first years following attack treatment. Five (35,7%) patients was the survival rate within five years starting early treatemt. After five years, three (21,4%) patients were alive: for 18 and 14 year, and 64 month period; two patients died at 62 and 64 months. It is concluded that this survival may be increased by initial behaviour enclosed at the technologic therapeutic patterns of the the Institute of Oncology and Radiobiology, of Havana City. (author).

461

Effect of irradiation on bone remodelling and the structural integrity of the vertebral column. Doctoral thesis  

Energy Technology Data Exchange (ETDEWEB)

The effects of therapeutic levels of radiation on the axial properties of the primate vertebral column were studied. Seven male rhesus monkeys (Macaca mulatta) were irradiated with a single does of 1300 cGy to the specific lumbar vertebrae of L2, L3, and L4. Three additional animals served as controls. Radiographs were taken before the radiation treatment and just prior to sacrifice to determine density changes in the bone. The animal subjects were sacrificed 105 days following the radiation exposure. Biomechanical testing was completed on lumbar levels 2 and 3 to identify changes in strength characteristics following radiation treatment. Histomorphometric analysis of lumbar vertebrae level 4 was completed to identify volume and surface density changes as well as cellular changes. Tetracycline, dicarbomethylaminomethyl fluorescein (DCAF), and xylenol orange were used as bone labeling agents to aid in the histomorphometry and to obtain dynamic parameter changes.

1990-01-01

462

Do gender and torus mandibularis affect mandibular cortical index? A cross-sectional study  

Science.gov (United States)

BackgroundThe interactions between torus and several factors such as age, gender, and dental status have not been studied comprehensively. The purpose of this study was to determine the effect of gender on the mandibular cortical index (MCI) and to investigate a possible association between torus mandibularis (TM) and MCI.MethodsThe study consisted of 189 consecutive patients referred to Department of Oral Diagnosis and Radiology of Hacettepe University within 30 workdays. Patients who did not have systemic disorders affecting bone density were included; and the age, gender, dental status and existing TM of the patients were recorded. Morphology of the mandibular inferior cortex was determined according to Klemitti's classification on panoramic radiographs.ResultsMCI was affected by age and gender (P 0.05).ConclusionIn the study population, MCI was affected by age and gender. As age increased, semilunar defects could be seen on the cortex of the mandible and MCI ...

2007-10-30

463

Digital image precessing for neutron television fluoroscopic system and its application to neutron computed tomography  

Energy Technology Data Exchange (ETDEWEB)

The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the reconstructed image. The image quality could be satisfactory to distinguish acrylic ...

1984-09-01

464

Digital image precessing for neutron television fluoroscopic system and its application to neutron computed tomography  

International Nuclear Information System (INIS)

The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the reconstructed image. The image quality could be satisfactory to distinguish acrylic ...

1984-01-01

465

Digital direct magnification mammography with storage phosphor screens. Standardized and image result dependent post-processing parameters  

International Nuclear Information System (INIS)

Present day mammography has not been able to make use of the advantages of digital luminescence radiography because of the limited spatial resolution. The recent development of electromagnetic focusing X-ray tube with effective focal spot sizes from 0.04 to 0.12 mm allows radiographic direct magnification with less geometric blur. It is now possible to combine direct magnification mammography with digital luminescence radiography. By combining high quality storage phosphor screens with an HQ-workstation a spatial resolution of 8 lp/mm is possible for 1.7-fold magnification. For 4-fold spot magnification views spatial resolution can be theoretically increased to approx. 20 lp/mm. One important advantage of digital radiography is the possibility of image-postprocessing. This article presents two sets of standard parameters and three sets of image dependent parameters for better imaging of specific lesions, such as microcalcifications. The introduction of the storage ...

466

Determination of time-dependent void fraction distribution in bubbly two-phase flow by a real-time neutron radiography technique  

Energy Technology Data Exchange (ETDEWEB)

Radiographic images generated by the real-time neutron radiography system (RTNR) are analyzed by customized image processing software of the determination of instantaneous void fraction distribution. The cross-sectional averaged axial void fraction profiles and the two-dimensional void fraction profiles are determined simultaneously for each image. Various flow regimes are generated to determine if the RTNR system can accurately predict the void distribution in the radial, axial, and temporal coordinates. The results show the RTNR system correctly determines the void fraction distribution for each flow regime; however, accuracy decreases with decreasing void fraction. For net water thicknesses > 1.0 cm, the accuracy decreases with increasing water thickness due to the extreme sensitivity of thermal neutron interactions with light water. Heavy water is a more suitable fluid than light water for void fraction measurements in large-diameter flow systems.

1995-01-01

467

Dental caries in adolescents with attention deficit hyperactivity disorder: a population-based follow-up study  

British Library Electronic Table of Contents (United Kingdom)

Blomqvist M, Ahadi S, Fernell E, Ek U, Dahllf G. Dental caries in adolescents with attention deficit hyperactivity disorder: a population-based follow-up study. Eur J Oral Sci 2011; 119: 381-385. 2011 Eur J Oral Sci This study tested the hypothesis that adolescents with attention deficit hyperactivity disorder (ADHD) exhibit a higher prevalence of caries than adolescents in a control group. Thirty-two adolescents with ADHD and a control group of 55 adolescents from a population-based sample, all 17-yr of age, underwent a clinical and radiographic dental examination. The mean--SD number of decayed surfaces (DS) was 2.0--2.2 in adolescents with ADHD and 0.9--1.4 in adolescents of the control group. Thirty-one per cent of the adolescents in the ADHD group had no new caries lesions (DS-=-0) co...

2011-01-01

468

Demonstration of mobile accelerator neutron radiography for in situ detection of moisture and corrosion in aircraft structures  

Energy Technology Data Exchange (ETDEWEB)

A demonstration of the first mobile 'on-off' neutron radiography system, developed by Vought Corporation Advanced Technology Center, has been conducted at McClellan Air Force Base. On-site neutron radiography operations with the engineering model were carried out to demonstrate the potential of such a system for in situ detection of hidden moisture and corrosion in aircraft structures, and to assess the performance of the unique hardware system in a depot environment. Inspections were performed on F-111 and F-106 aircraft, and several structures removed from T-39 and A-10 aircraft were also inspected. The effectiveness of the new N-ray system for imaging moisture and corrosion was confirmed after subsequent removal of skins from some of the F-111 structures. Excellent correlation of radiographic images with actual moisture and corrosion damage was attained. Both film and real time/near real time neutron imaging were demonstrated. These results, ...

1983-01-01

469

Comparison of the quality of the chest film between digital radiography and conventional high kV radiography  

International Nuclear Information System (INIS)

Objective: To evaluate the quality and usefulness of direct digital radiography system in roentgenogram of chest in clinical practice. Methods: 1000 cases of chest roentgenograms with digital radiography and high kV conventional radiography were selected for analysis by 3 senior radiologists. Results: 1. With digital radiography system, the quality of chest film was assessed as grade A in 50.6%, grade B in 38.5%, grade C in 10.9%, and no waste film. 2. With conventional high kV radiography, the quality of chest film was assessed as grade A in 41.1%, grade B in 44.1%, grade C in 13.3%, and waste film in 1.5%. The direct digital radiography was statistically superior to the conventional high kV radiography. 3. The fine structure of the lungs could be revealed in 100.0% of chest roentgenogram with direct digital radiograph system, which was significantly higher than that acquired with the conventional high KV radiography (78.6%, P < 0.001). Conclusion: Direct ...

2003-02-01

470

Body dose conversion factors for computerized tomography  

International Nuclear Information System (INIS)

While there have been many experimental and calculational investigations on absorbed dose distribution in the patient resulting from conventional X-ray procedures, such data for computerized tomography (CT) are still sparse. As this diagnostic procedure has shown a rapid increase in application during recent years, we have determined absorbed dose to body organs in a human phantom resulting from CT examinations. The exposure model consists of the heterogeneous MIRD-5 phantom and a suitable Monte-Carlo method to calculate absorbed dose to organs of interest. The exposure conditions are specified according to the exposure specifications of a CT-scanner currently in use. The calculations cover the range of body tissues of interest in terms of organ absorbed doses as well as a risk weighted absorbed dose. A detailed example showing the calculation of red bone marrow dose is given and a somatic effective dose equivalent Hsub(ES) is calculated for different conventional and CT-scanning ...

1980-10-31

471

Automated segmentation and quantitative characterization of radiodense tissue in digitized mammograms  

International Nuclear Information System (INIS)

Mammography has emerged as a reliable non-invasive technique for the early detection of breast cancer--the second leading cause of cancer-related mortality among American women. The radiographic appearance of the female breast consists of radiolucent (dark) regions due to fat and radiodense (light) regions due to connective and epithelial tissue. The amount of radiodense tissue can be used as a marker for predicting breast cancer risk. This paper presents the development of an algorithm for estimating the percentage of radiodense tissue in a digitized mammogram. The technique involves determining a dynamic threshold for segmenting radiodense indications in mammograms. Both the mammographic image and the threshold are modeled as Gaussian random variables. This work is intended to support a concurrent study at the Fox Chase Cancer Center (FCCC) exploring the association between dietary patterns and breast cancer risk. Mammograms have been obtained from an existing ...

2002-05-25

472

Assessment of the effects of pixel loss on image quality in direct digital radiography  

Energy Technology Data Exchange (ETDEWEB)

Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitative image quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line pairs phantom were found to be more sensitive to pixel loss. Measurement of the MTF, NPS and DQE can ...

2004-03-21

473

Assessment of the effects of pixel loss on image quality in direct digital radiography  

International Nuclear Information System (INIS)

Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitative image quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line pairs phantom were found to be more sensitive to pixel loss. Measurement of the MTF, NPS and DQE can reveal small changes in image quality ...

2004-03-21

474

A systematic review to investigate the effectiveness and acceptability of interventions for moist desquamation in radiotherapy patients  

Energy Technology Data Exchange (ETDEWEB)

Aim: To systematically review the currently available high quality evidence evaluating treatments for moist desquamation in radiotherapy patients. Design: Systematic literature review. Methods: Electronic databases, websites, reference lists, key journals and conference proceedings were searched. Attempts were also made to uncover unpublished material. Relevant studies proceeded to data extraction and quality assessment. Results: Twenty studies were found; 10 were eligible for inclusion. Although many studies were small, none had unacceptably poor quality. No meta-analysis was undertaken as the studies were not homogenous in their interventions or methods. No convincing evidence for any intervention was found. Conclusion: Despite being recommended by many guidelines (College of Radiographers Summary of Intervention for Acute Radiotherapy Induced Skin Reactions in Cancer Patients (London, 2001); NHS Quality Improvement Scotland Best Practice Statement: Skincare of ...

2009-08-15

475

A summary of neutron radiography and neutron radioscopy applications at the University of Michigan Phoenix Memorial Laboratory  

International Nuclear Information System (INIS)

Neutron radiography and neutron radioscopy are rapidly becoming the valuable tools for nondestructive testing and basic research. The Phoenix Memorial Laboratory has developed a neutron facility capable of both film neutron radiography and real time neutron radioscopy, and has used this facility to study several phenomena of interest to the researchers in many areas. Neutrons can be used for imaging the phenomena that X-ray cannot image, such as the presence, absence or movement of hydrogenous materials inside metals such as aluminum or steel. There are three basic methods for obtaining images using neutrons: high resolution film neutron radiography, real-time neutron radioscopy and transfer film neutron radiography. The neutron radiography facility at Phoenix Memorial Laboratory, the neutron radioscopic imaging systems, the neutron radiographic detectors, lubrication studies, spray imaging, flow in porous media, three-dimensional computer-reconstructed neutron ...

1992-03-01

476

Stochastic risk estimation from medical x-ray diagnostic examinations, 3  

International Nuclear Information System (INIS)

The genetically significant dose (GSD), per Caput mean bone marrow dose (CMD), leukemia significant dose (LSD) and malignancy significant dose (MSD) from medical diagnostic X-ray examinations in Japan were estimated based on a 1979 nationwide survey of randomly sampled hospitals and clinics. The population risk estimates were carried out using the resultant values of GSD, LSD and MSD. In the risk estimates, the significant factors, namely, the relative child expectancy, the leukemia significant factor and the malignancy significant factor, for patients were assumed to be same as those of general population. The risk factors used were 185 x 10"-"6 rad"-"1 for genetic risk of all generations, 20 x 10"-"6 rad"-"1 for fatal leukemia and 165 x 10"-"6 rad"-"1 for fatal malignant diseases, respectively. The resultant annual population doses per person were 15 mrad (0.15 mGy) for GSD, 107 mrad (1.07 mGy) for CMD, 86 mrad (0.86 mGy) for LSD and 43 mrad (0.43 mGy) for MSD, respectively. The ...

477

e#gamma# and #gamma##gamma# colliders  

International Nuclear Information System (INIS)

The results that can be expected by e#gamma# and #gamma##gamma# colliders in future are summarized. e#gamma# and #gamma##gamma# colliders have many fine possibilities, and are the economical selection for utilizing future e"+e"- colliders more effectively. e#gamma# and #gamma##gamma# colliders were proposed by former USSR researchers at the beginning of 1980s, but recently, the prospect of realizing future e"+e"- collision type linear accelerator projects has become high, they have become to be considered seriously as the option of remodeling them. The high energy photon beam of e#gamma# and #gamma##gamma# colliders is obtained by causing Compton reverse scattering, irradiating laser beam to the electron beam of e"+e"- accelerators. The production of #gamma#-beam is explained. As for the physics noteworthy in e#gamma# colliders, abnormal gauge coupling, the formation of Higgs particles, excited leptons, lepto-quark, supersymmetric particles and top quark are ...

1994-02-01

478

Study on grain growth of fine grained WC-Co hardmetal by numerical calculation  

Energy Technology Data Exchange (ETDEWEB)

This paper reviews our simulation study by numerical calculation based on two-, three- and multi-grain-size models on WC grain growth in fine grained WC-Co hardmetal doped with VC. The study aimed to presume or predict the following: (1) the cause and conditions for the abnormal grain growth which occurs in some cases in the fine grained hardmetal prepared from fine WC powders with mean grain size below about 0.2{mu}m, and (2) how the mean grain size of the hardmetal varies with decreasing mean grain size of the WC starting powder to 0.1 pm or nano-meter size. The calculation results by these three kinds of models suggested the following, respectively: (1) the occurrence of the abnormal grain growth is generally substantial for WC starting powder with bimodal size-distribution and mean gram size below 0.1 - 0.2{mu}m, and not due to the non-uniform distribution of the grain growth inhibitor, (2) the introduction of middle grains caused the ...

2000-12-15

479

Sodium arsanilate-induced vestibular dysfunction in meadow voles (Microtus pennsylvanicus): effects on posture, spontaneous locomotor activity and swimming behavior.  

Science.gov (United States)

Vestibular dysfunction was chemically induced in male meadow voles (Microtus pennsylvanicus) by intratympanic injections (30 mg per side) of sodium arsanilate (atoxyl). The control group received intratympanic injections of isotonic saline. After a one-week recovery period the voles were behaviorally assayed for integrity of their labyrinthine systems. All subjects were tested for the presence of the air-righting reflex and body rotation-induced nystagmus. Three weeks later a multivariate assessment of spontaneous motor activity of the voles was carried out in the automated Digiscan Activity Monitor. In addition, the swimming behavior of the voles was examined. Voles with vestibular dysfunction exhibited pronounced postural abnormalities (head dorsiflexion), were not able to swim with their nose above the water for a 1 min test period, and displayed disorientation and thrashing movements. In the Digiscan activity test the atoxyl-treated voles displayed ...

1992-03-15

480

Radioguided occult lesion localization versus wire-guided localization for non-palpable breast lesions: randomized controlled trial  

Scientific Electronic Library Online (English)

Abstract in english AIM: This prospective randomized clinical study was conducted to compare radioguided occult lesion localization (ROLL) with wire-guided localization to evaluate optimum localization techniques for non-palpable breast lesions. METHODS: A total of 108 patients who were undergoing an excisional biopsy for non-palpable breast lesions requiring pathologic diagnosis were randomly assigned to the ROLL group (n = 56) and wire-guided localization group (n = 52). In the study, pati (more) ents' characteristics, radiological abnormalities, radiological technique of localization, localization time, operation time, weight of the excised specimen, clearance margins, pathological diagnosis and perioperative complications were assessed. RESULTS: There were no differences between the two groups in terms of age, radiological abnormalities and localization technique (p = non-significant for all). ROLL techniques resulted in 100% retrieval of ...

2011-01-01

481

Platelet fibrinogen binding in Basset Hound Hereditary Thrombopathy  

Energy Technology Data Exchange (ETDEWEB)

Platelets from dogs with Basset Hound Hereditary Thrombopathy (BHT) display a thrombasthenia-like aggregation defect but have been shown to have normal amounts of platelet membrane glycoproteins IIb and IIIa (GP IIb-IIIa). In order to investigate the possibility of a functionally abnormal GPIIb-IIIa complex, which might be unable to bind fibrinogen after stimulation, fibrinogen binding in BHT was evaluated. Two canine fibrinogen preparations were used, one from BHT dogs and one from normal control dogs, as well as a human fibrinogen preparation. Platelets from BHT and normal dogs were activated with 1 x 10/sup -5/M ADP in the presence of /sup 125/I-labeled fibrinogen and the surface bound radioactivity quantitated. For all fibrinogen preparations, the amount of fibrinogen bound by BHT platelets was not significantly different than that bound by normal dog platelets. BHT platelets bound 23,972 +/- 3612 and normal dog platelets bound 23,033 +/- 3971 molecules of ...

1986-03-01

482

E{gamma} and {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

The results that can be expected by e{gamma} and {gamma}{gamma} colliders in future are summarized. e{gamma} and {gamma}{gamma} colliders have many fine possibilities, and are the economical selection for utilizing future e{sup +}e{sup -} colliders more effectively. e{gamma} and {gamma}{gamma} colliders were proposed by former USSR researchers at the beginning of 1980s, but recently, the prospect of realizing future e{sup +}e{sup -} collision type linear accelerator projects has become high, they have become to be considered seriously as the option of remodeling them. The high energy photon beam of e{gamma} and {gamma}{gamma} colliders is obtained by causing Compton reverse scattering, irradiating laser beam to the electron beam of e{sup +}e{sup -} accelerators. The production of {gamma}-beam is explained. As for the physics noteworthy in e{gamma} colliders, abnormal gauge coupling, the formation of Higgs particles, excited leptons, lepto-quark, supersymmetric ...

1994-02-01

483

Digital atlas of fetal brain MRI  

International Nuclear Information System (INIS)

Fetal MRI can be performed in the second and third trimesters. During this time, the fetal brain undergoes profound structural changes. Interpretation of appropriate development might require comparison with normal age-based models. Consultation of a hard-copy atlas is limited by the inability to compare multiple ages simultaneously. To provide images of normal fetal brains from weeks 18 through 37 in a digital format that can be reviewed interactively. This will facilitate recognition of abnormal brain development. T2-W images for the atlas were obtained from fetal MR studies of normal brains scanned for other indications from 2005 to 2007. Images were oriented in standard axial, coronal and sagittal projections, with laterality established by situs. Gestational age was determined by last menstrual period, earliest US measurements and sonogram performed on the same day as the MR. The software program used for viewing the atlas, written in C, permits linked ...

2010-02-01

484

Defecographic diagnosis of the puborectalis syndrome; Diagnosi mediante defecografia della sindrome del muscolo puborettale  

Energy Technology Data Exchange (ETDEWEB)

The puborectalis syndrome is a defecation disorder supported by the nonrelaxation of puborectalis sling with consequent dyschezia. They report on a series of 98 patients submitted to clinical examination, defecography, anorectal manometry, electromyography and intestinal transit time studies. The main symptoms of puborectalis syndrome in their patients were incomplete defecation (89 %) and intermittent evacuation (63 %); 28 % of patients turned to finger defecation. In all patients, defecography showed an abnormal increase in puborectalis impression on the posterior anorectal wall, reduced anorectal angle opening under straining (mean value: 113 deg) and prolonged expulsion time with barium pooling in the ampulla (mean evacuation time: 38 seconds). Such anorectal abnormalities as rectal mucosal prolapse (47 cases) and anterior rectocele (36 cases) were also associated. In 33 of 98 patients (34 % of cases), sling assessment by bidigital ...

1997-04-01

485

Defecographic diagnosis of the puborectalis syndrome  

International Nuclear Information System (INIS)

The puborectalis syndrome is a defecation disorder supported by the nonrelaxation of puborectalis sling with consequent dyschezia. They report on a series of 98 patients submitted to clinical examination, defecography, anorectal manometry, electromyography and intestinal transit time studies. The main symptoms of puborectalis syndrome in their patients were incomplete defecation (89 %) and intermittent evacuation (63 %); 28 % of patients turned to finger defecation. In all patients, defecography showed an abnormal increase in puborectalis impression on the posterior anorectal wall, reduced anorectal angle opening under straining (mean value: 113 deg) and prolonged expulsion time with barium pooling in the ampulla (mean evacuation time: 38 seconds). Such anorectal abnormalities as rectal mucosal prolapse (47 cases) and anterior rectocele (36 cases) were also associated. In 33 of 98 patients (34 % of cases), sling assessment by bidigital ...

486

Cold pressor test myocardial perfusion SPECT as a predictor of the development of ischemia at exercise in the follow up of asymptomatic patients with moderate cardiovascular risk  

International Nuclear Information System (INIS)

Introduction: Previous studies have published the correlation between myocardial perfusion SPECT (MP) during cold pressor test (CPT) and intracoronary acetylcholine and its usefulness as independent marker of endothelial dysfunction (ED). Objective: To analyze the incidence of positivization of MP exercise studies in the follow up of asymptomatic patients with moderate cardiovascular risk (CV) and ED detected by PF. Material and Methods: Of 301 patients of the PARADIGMA Registry (normal exercise MP SPECT and clinical probability < 20% of events at 10 years [moderate risk by Framingham index]) 55 had positive PF (+) (18.3%). Prospectively and consecutively, 15 asymptomatic patients with PF (+), and a control group (CG) of 15 patients with negative PF, with paired sex, age and coronary risk factors (CRF), that accomplished a 12 #+-# 2 months follow up, and that underwent a new exercise and resting MP SPECT were analyzed. An MP extension score was used in a model of 17 segments. The ...

487

Assessment of left ventricular wall motion by optional multiple long-axial gated blood pool SPECT  

International Nuclear Information System (INIS)

Optional multiple long-axial gated blood pool SPECT images were prepared for the purpose of stereoscopic and quantitative imaging of left ventricular wall motion (LVWM). Sixteen patients with ischemic heart disease and 8 healthy subjects were imaged in 32 views in the 360 degrees position after iv injection of 740 MBq of Tc-99m-labeled human serum albumin D. The R-R interval was divided into 16. After preparing conventional oblique images, long-axial images were prepared. Shortening rate of left ventricular wall was calculated in 5 segments of the apex and base of the left ventricle. An average shortening rate in each segment was graded with a score from a minimum of 0 to a maximum of 40% or more. In the normal group, shortening rate in each segment, except for the base of the septal region, exceeded 40%. In the group of ischemic heart disease, radial shortening was capable of visualizing the degree and extent of the whole LVWM abnormality. LVWM ...

1991-01-01

488

Paraquat-induced pulmonary lesions : HRCT findings in long-term follow-up : a case report  

International Nuclear Information System (INIS)

We illustrate serial HRCT findings over a 16-month period in a 35-year-old woman who had ingested paraquat. Initial areas of ground-glass opacity changed into areas of multiple air cysts on follow up scan obtained five months after ingestion. A further follow-up scan obtained 16 months after ingestion showed improvement, with increased lung volume and normalized lung architecture.

1997-03-01

489

Measuring and Explaining Electricity Price Changes in Restructured States  

Energy Technology Data Exchange (ETDEWEB)

An effort to determine the effect of restructuring on prices finds that, on average, prices for industrial customers in restructured states were lower, relative to predicted prices, than prices for industrial customers in non-restructured states. This preliminary analysis also finds that these price changes are explained primarily by high pre-restructuring prices, not whether or not a state restructured. (author)

2006-06-15

490

MR findings of primary Ewing's sarcoma of greater wing of sphenoid  

International Nuclear Information System (INIS)

Primary Ewing's sarcoma of the skull is a very rare entity. We report MRI findings in a case of Ewing's sarcoma of the greater wing of sphenoid in a 4-year-old patient. Magnetic resonance imaging showed markedly heterogenous signal intensity with areas of haemorrhage and necrosis. It also demonstrated the exact extent of tumour due to its multiplanar capabilities and was, therefore, helpful in planning surgery. Copyright (2002) Blackwell Science Pty Ltd

2002-12-01

491

Intrasphenoid cephalocele: MRI in two cases  

Energy Technology Data Exchange (ETDEWEB)

The intrasphenoid form of basal cephalocele is uncommon. We describe the clinical, CT and MRI findings in two cases presenting in middle age with persistent cerebrospinal fluid rhinorrhoea. Emphasis is placed upon the imaging findings which aid in discrimination of intrasphenoidal cephalocele from more common causes of a sphenoid sinus mass. (orig.)

1999-07-01

492

Geosynchronous orbit magnetopause crossings  

Energy Technology Data Exchange (ETDEWEB)

In this study we extend the analysis of magnetopause crossings observed with Magnetospheric Plasma Analyzer measurements to examine a much larger statistical data set. This study examines 39 maiznetosheath/LLBL intervals from 79 spacecraft-months of observations: these observations were taken from a survey of data from the start of each spacecraft mission and extending through March 1993. In contrast to the previous findings, we find no evidence for a significant dawn/dusk asymmetry in geosynchronous magnetopause crossings.

1994-07-01

493

Finding two-dimensional peaks  

CERN Document Server

Two-dimensional generalization of the original peak finding algorithm suggested earlier is given. The ideology of the algorithm emerged from the well known quantum mechanical tunneling property which enables small bodies to penetrate through narrow potential barriers. We further merge this ``quantum'' ideology with the philosophy of Particle Swarm Optimization to get the global optimization algorithm which can be called Quantum Swarm Optimization. The functionality of the newborn algorithm is tested on some benchmark optimization problems.

2004-01-01

494

Finding the best quadratic approximation of a function  

British Library Electronic Table of Contents (United Kingdom)

This article examines the question of finding the best quadratic function to approximate a given function on an interval. The prototypical function considered is f(x) = ex. Two approaches are considered, one based on Taylor polynomial approximations at various points in the interval under consideration, the other based on the fact that three non-collinear points determine a unique quadratic function. Three different techniques for measuring the error in the approximations are considered.

2011-01-01

495

Action plan for the Tiger Team assessment report  

Energy Technology Data Exchange (ETDEWEB)

This document contains responses and planned actions that address the findings of the Tiger Team Assessment of Brookhaven National Laboratory, June 1990. In addition, the document contains descriptions of the management and organizational structure to be used in conducting planned actions, root causes for the problems identified in the findings, responses, planned actions, schedules and milestones for completing planned actions, and, where known, costs associated with planned actions.

1990-08-30

496

A guide to choosing a school : Directgov - Parents  

Wastenet

...authority's and schools' prospectuses Finding a school to suit your child School performance: test results and Ofsted reports Applying for a school place Once you ... Finding a school to suit your child School performance: test results and Ofsted reports Applying for a school place: admissions criteria Apply for ...

497

Evaluation of left ventricular volumes in patients with congenital heart disease and abnormal left ventricular geometry. Comparison of MRI and transthoraic 3-dimensional echocardiography; Vergleich der transthorakalen 3D-Echokardiographie mit der MRT zur Bestimmung linksventrikulaerer Volumina bei Patienten mit pathologischer Ventrikelgeometrie aufgrund angeborener Herzfehler  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To assess the new method of 3-dimensional echocardiography in comparison to the 'gold standard' MRI as to its ability to calculate left ventricular volumes in patients with congenital heart disease. Materials and methods: Eighteen patients between the ages of 3.9 to 37.3 years (mean: 12.8{+-}9.7) with a geometrically abnormal left ventricle were examined using a 1.5 T scanner with a fast gradient-echo sequence (TR=14 ms, TE=2.6-2.9 ms, FOV=300-400 mm, flip angle=20 , matrix=128:256, slice thickness=5 mm, retrospective gating) in multislice-multiphase technique. Transthoracic 3D-echocardiography was performed with a 3.5 MHz transducer and a Tomtec {sup trademark} (Munich, Germany) system for 3D reconstruction. Results: Volume calculation was possible in all patients with 3D-echocardiography, but the muscle mass calculation only succeeded in 11 to 18 patients (61%) due to inadequate visualization of the entire myocardium. Comparing MRI and ...

2003-07-01

498

Dynamic enhanced MRI of the subacromial bursa: correlation with arthroscopic and histological findings  

Energy Technology Data Exchange (ETDEWEB)

Objective: To assess dynamic MRI with Gd-DTPA enhancement for evaluating inflammatory changes in the subacromial bursa. Design and patients: We detected the signal intensity changes in dynamic MRI of the subacromial bursa, and confirmed these macroscopically by arthroscopy and histologically. The signal intensity was measured using built-in software, and the enhancement ratio (E ratio) was calculated from dynamic MR images. In addition, as a parameter of the rate of the increase in the signal intensity from 0 to 80 s, the mean increase per second in the E ratio was obtained as the coefficient of enhancement (CE). The correlation was studied of the E ratio and CE with the arthroscopic findings (redness, villous formation, thickening and adhesion), and of the E ratio and CE with the histological findings (capillary proliferation, papillary hyperplasia, fibrosis and inflammatory cell infiltration) of the subacromial bursa. Of patients with ...

2003-09-01

499

IT IS THE EYES AND NOT THE SIZE THAT MATTER  

British Library Electronic Table of Contents (United Kingdom)

The number of immigrants to Western Europe has been increasing, with immigration the subject of much controversy in contemporary Europe. In this article, we investigate the relationship between the size of the immigrant population, how natives perceive this size, and their anti-immigrant attitudes. We use data from the 2002/2003 European Social Survey covering 17 Western European countries, and we find that as a rule Western Europeans think that the immigrant population in their country is much larger than it actually is. The perceived size of an immigrant population has an impact on anti-immigrant prejudices, but the real size does not. Like many authors before us, we find that education reduces prejudice. However, we also find that around 10 percent of the total effect of education is a ...

2011-01-01

500

Care programmes and integrated care pathways  

British Library Electronic Table of Contents (United Kingdom)

Purpose - The article discusses how care programmes and integrated care pathways can be linked, finding ways to improve healthcare process professional and logistical quality from a supply chain and a network point-of-view. Design/methodology/approach - The authors argue that owing to cost containment goals and increasing healthcare demand, healthcare services systems are challenged to improve service quality, whilst at the same time finding ways to improve delivery processes. It explores if the combination of two instruments, care programmes and integrated care pathways, can meet both goals. This combination is illustrated by an example from the Institute of Mental Health Care Eindhoven en de Kempen. Findings - Analysis suggests that care programmes can be combined with integrated care pa...

2008-01-01