Probing the Mechanisms of an Air Amplifier using a LTQ-FT-ICR-MS and Fluorescence Spectroscopy
UK PubMed Central (United Kingdom)
We report the first quantitative assessment of electrosprayed droplet/ion focusing enabled by the use of a voltage-assisted air amplifier between an electrospray ionization emitter and a hybrid...Full Text Available
2007-11-01
UK PubMed Central (United Kingdom)
A fast and sensitive LC-ESI-MS method is described for the comparative quantification of 16 estrogen metabolites based on the derivatization of estrogens with a novel derivatizing reagent, N-methyl-nicotinic...Full Text Available
2008-07-15
British Library Electronic Table of Contents (United Kingdom)
A comprehensive and highly selective method for detecting in bacterial supernatants a modified sulfur nucleoside, S-adenosyl-L-methionine (SAM), and its metabolites, i.e., S-adenosylhomocysteine (SAH), adenosine (Ado), 5prime-deoxy-5prime-methylthioadenosine (MTA), adenine (Ade), S-adenosyl-methioninamine (dcSAM), homocysteine (Hcy) and methionine (Met), was developed. The method is based on reversed-phase liquid chromatography with positive electrospray ionization (ESI+) coupled to a hybrid linear quadrupole ion trap (LTQ) and 7-T Fourier transform ion cyclotron resonance mass spectrometry (FTICRMS). A gradient elution was employed with a binary solvent of 0.05 M ammonium formate at pH 4 and acetonitrile. The assay involves a simultaneous cleanup of cell-free bacterial broths by solid-pha...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
Negative ion electrospray ionization (ESI) coupled with high field Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) allows for the direct detection of acidic NSO compounds in petroleum. The technique requires no chromatographic separation, is able to distinguish 18 different compound classes (e.g., neutral nitrogen, carboxylic acids and oxygenates), and can identify {approx}14,000 distinct masses by ultra-high mass resolution and mass accuracy. We previously studied three crude oils from different geological origins [Organic Geochemistry 33 (2002b) 743-759]. Here, we expand our research by comparing two source-equivalent Smackover oils of different levels of thermal maturity. We observe clear differences in the distribution of NSO compound classes, types (number of rings plus double bonds within a class), and number of alkyl carbons. With increasing thermal stress, the relative amount of sulfur and oxygen containing ...
2004-07-01
UK PubMed Central (United Kingdom)
Charge reduction electrospray mass spectrometry (CREMS) reduces the charge states of electrospray-generated ions, which concentrates the ions from a protein into fewer peaks spread over a larger...Full Text Available
2005-11-01
Energy Technology Data Exchange (ETDEWEB)
The diminishing clean oil reserve is driving the search for new or improved ways to reduce the level of NSO-containing species found in high abundance in heavy crude oils. Hydrotreatment is the currently preferred technique to remove those polar species. Unfortunately, nitrogen-containing compounds cause coke formation on the surface of the hydrotreatment catalyst, leading to partial or complete deactivation. Here, positive- and negative-ion electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI FT-ICR MS) identify those nitrogen compounds that resist hydrotreatment. ESI preferentially ionizes polar (e.g., heteroatom-containing) species: basic molecules are detected as positive ions and acidic/neutral molecules as negative ions. FT-ICR MS resolves thousands of species in a single mass spectrum, allowing for unambiguous determination of elemental composition, C{sub c}H{sub h}N{sub n}O{sub ...
2006-10-15
Energy Technology Data Exchange (ETDEWEB)
Acidic constituents in crude oil are associated with the formation of stable emulsions during production and present a challenge for efficient oil recovery and processing. Acid molecules, including naphthenic acids and acidic sulfur in crude oil cause corrosion in refineries and pipelines. Naphthenic acids are also significant because of their surface activity and marginal water solubility, so that they may leach to wastewaters and cause adverse environmental effects. Acidic components of oil are not limited to carboxylic acids but also molecules that contain sulfur and nitrogen. As such, an improved understanding of the chemistry and physics of petroleum at the molecular level is needed in order to understand the range of problems associated with acidic oil components and to design better solutions. The applications of negative-ion electrospray ionization (ESI) Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) for ...
2008-07-01
British Library Electronic Table of Contents (United Kingdom)
A simple, sensitive and rapid method for analysis of granisetron in human plasma, utilizing liquid chromatography tandem mass spectrometry (LC-MS/MS), has been developed and validated to satisfy FDA guidelines for bioanalytical methods. The analyte and internal standard (IS) were isolated from 100ml plasma samples by liquid-liquid extraction (LLE). A Varian 1200l tandem mass spectrometer equipped with an electrospray ionization source was operated in selected reaction monitoring (SRM) mode with the precursor-to-product ion transitions m/z 313.4/138 for granisetron and m/z 270/201 for the IS used for quantitation. The assay exhibited a linear dynamic range of 0.02-20ng/ml for granisetron in human plasma. The lower limit of quantification (LLOQ) was 0.02ng/ml with a relative standard deviati...
2006-01-01
Ionic conduction in polyether-based lithium arylfluorosulfonimide ionic melt electrolytes
Energy Technology Data Exchange (ETDEWEB)
We report synthesis, characterization and ion transport in polyether-based ionic melt electrolytes consisting of Li salts of low-basicity anions covalently attached to polyether oligomers. Purity of the materials was investigated by HPLC analysis and electrospray ionization mass spectrometry. The highest ionic conductivity of 7.1 x 10{sup -6} S/cm at 30 deg. C was obtained for the sample consisting of a lithium salt of an arylfluorosulfonimide anion attached to a polyether oligomer with an ethyleneoxide (EO) to lithium ratio of 12. The conductivity order of various ionic melts having different polyether chain lengths suggests that at higher EO:Li ratios the conductivity of the electrolytes at room temperature is determined in part by the amount of crystallization of the polyether portion of the ionic melt.
2009-10-01
Ionic conduction in polyether-based lithium arylfluorosulfonimide ionic melt electrolytes
International Nuclear Information System (INIS)
We report synthesis, characterization and ion transport in polyether-based ionic melt electrolytes consisting of Li salts of low-basicity anions covalently attached to polyether oligomers. Purity of the materials was investigated by HPLC analysis and electrospray ionization mass spectrometry. The highest ionic conductivity of 7.1 x 10-6 S/cm at 30 deg. C was obtained for the sample consisting of a lithium salt of an arylfluorosulfonimide anion attached to a polyether oligomer with an ethyleneoxide (EO) to lithium ratio of 12. The conductivity order of various ionic melts having different polyether chain lengths suggests that at higher EO:Li ratios the conductivity of the electrolytes at room temperature is determined in part by the amount of crystallization of the polyether portion of the ionic melt.
2009-10-01
British Library Electronic Table of Contents (United Kingdom)
Phenytoin (PHT), phenobarbital (PHB), lamotrigine (LTG), and topiramate (TPM) are some of the most widely used antiepileptic drugs (AEDs). Monitoring of their concentrations in serum is important for the treatment of epilepsy. A reference measurement procedure (RMP) for certification of PHT, PHB, LTG, and TPM in serum has been developed and critically evaluated. Isotopically labeled compounds of PHT, PHB, LTG, and TPM are used as internal standards for the four AEDs. The four drugs and their respective labeled internal standards are simultaneously extracted from serum using solid-phase extraction prior to reversed-phase liquid chromatography?tandem mass spectrometry (LC-MS/MS). Chromatographic separation was performed using a C18 column. Electrospray ionization (ESI) in the positive ion mo...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
Among pharmaceuticals and personal care products released into the aquatic environment, antibiotics are of particular concern, because of their ubiquity and health effects. Although scientists have recently paid more attention to the threat of antibiotics to coastal ecosystems, researchers have often focused on relatively few antibiotics, because of the absence of suitable analytical methods. We have therefore developed a method for the rapid detection of 36 antibiotic residues in coastal waters, including tetracyclines (TCs), sulfanilamides (SAs), and quinolones (QLs). The method consists of solid-phase extraction (SPE) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis, using electrospray ionization (ESI) in positive mode. The SPE was performed with Oasis HLB and Oasi...
2011-01-01
The interaction of fast alpha particles with pellet ablation clouds
International Nuclear Information System (INIS)
The energy spectra of energetic confined alpha particles are being measured using the pellet charge exchange method [R. K. Fisher, J. S. Leffler, A. M. Howald, and P. B. Parks, Fusion Technol. 13, 536 (1988)]. The technique uses the dense ablation cloud surrounding an injected impurity pellet to neutralize a fraction of the incident alpha particles, allowing them to escape from the plasma where their energy spectrum can be measured using a neutral particle analyzer. The signal calculations given in the above-mentioned reference disregarded the effects of the alpha particles' helical Larmor orbits, which causes the alphas to make multiple passes through the cloud. Other effects such as electron ionization by plasma and ablation cloud electrons and the effect of the charge state composition of the cloud, were also neglected. This report considers these issues, reformulates the signal level calculation, and uses a Monte-Carlo ...
Proteomic Analysis of Proteins Secreted by HepG2 Cells Treated with Butyl Benzyl Phthalate
British Library Electronic Table of Contents (United Kingdom)
Proteomic changes in proteins secreted by human hepatocellular carcinomas (HepG2) cells exposed to butyl benzyl phthalate (BBP) were evaluated. HepG2 cells were treated with three different concentrations of BBP (0, 10, or 25 ?M) for 24 or 48 h. Following incubation, the cells were subjected to proteomic analysis using two different pI ranges (4-7 and 6-9) and large-size two-dimensional gel electrophoresis. Results showed resolution of a total of 2776 protein spots. Of these, 29, including 19 upregulated and 10 downregulated proteins, were identified by electrospray ionization-mass spectrometry-mass spectrometry (ESI-MS/MS). Among these, the identities of cystatin C, Rho guanine nucleotide dissociation inhibitor, gelsolin, DEK protein, Raf kinase inhibitory protein, triose phosphate ...
2010-01-01
Electrophysiological Study and Catheter Ablation with 3D Mapping
... see and electrophysiological study and catheter ablation with 3D mapping. During the procedure, doctors look at the ... perform a electrophysiology study with ablation, using our 3D mapping system. Keep in mind, that during the ...
Influence of Fiber Loading on Thermal Ablation of PTFE,
... Accession Number : ADD431225. Title : Influence of Fiber Loading on Thermal Ablation of PTFE,. Corporate Author : Personal Author(s) : Letson,KN. ...
1979-07-16
A liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed for the simultaneous determination of the 10 major components of Da-Cheng-Qi decoction (rhein, emodin, aloe-emodin, chrysophanol, rheochrysidin, naringin, naringenin, hesperidin, magnolol and honokiol) in dog plasma. Plasma samples were spiked with internal standard (ibuprofen), acidified with HCl and extracted twice by liquid-liquid extraction using ethyl acetate. Separation was performed on a YMC-Pack ODS-A C(18) column (5 microm, 150 mm x 4.6 mm) and a C(18) guard column (5 microm, 4.0 mm x 2.0 mm) with methanol-water (92:8, v/v) at a flow rate of 0.3 mL/min. The LC/MS system was operated under the multiple reaction monitoring mode using electrospray ionization in the negative ion mode. All analytes showed good linearity over a wide concentration range (r>0.99). The linear range of the calibration curves was 5000-19.53 ng/mL for rhein; 400-3.13 ng/mL for ...
2009-05-21
International Nuclear Information System (INIS)
Full text: A novel protocol based on electrospray ionization (ESI) multiple stage high capacity ion trap (HCT) mass spectrometry (MS) was developed for glycosphingolipidomic surveys. The method was optimized for detailed structural elucidation of human brain gangliosides and particularly applied to human hippocampus-associated structures. The multiple stage MS experiments allowed for a complete structural characterization of GM1 ganglioside species, which was achieved by elucidation of the oligosaccharide sequence, identification of the GM1 a structural isomer from the data upon sialic acid localization along the sugar backbone and determination of the d18:1/18:0 of fatty acid/sphingoid base composition of the ceramide moiety. The methodology developed here is of general practical applicability for glycolipids and represents a step forward in the implementation of the advanced and most modern MS methods in glycomics. Gangliosides are ...
2006-10-25
... the pulmonary vein and because there's a gap, electricity is going across the ablation line and capturing ...
... 2009) Arrhythmia Electrophysiological Study and Catheter Ablation with 3D Mapping (Mercy Hospital, Miami, FL, 11/15/2007) ...
British Library Electronic Table of Contents (United Kingdom)
Superstrong shock waves of multimegabar level generated during ablation of an aluminum surface by intense (<1 PW/cm2) femtosecond laser pulses have been detected by observing the propagation of a shock wave in air from the ablated surface to a broadband piezoelectric receiver. The estimated initial pressure and velocity of the shock wave (ablation plume) agree well with data obtained earlier by various methods for shock waves propagating inside ablated targets.
2011-01-01
Electrospun nanofibers composed of biodegradable polymers are attractive candidates for cell culture scaffolds in tissue engineering. Their fine-meshed structures, resembling natural extracellular matrices, effectively interact with cell surfaces and promote cell proliferation. The application of electrospinning, however, is limited to two-dimensional (2D) or single tube-like scaffolds, and the fabrication of arbitrary three-dimensional (3D) scaffolds from electrospun nanofibers is still very difficult due to the fibers' continuous and entangled form. To address this issue, in this paper, we describe the use of phase-separation-assisted electrospray and electrostatic focusing to perform continuous direct 3D patterning of nanofibrous microcapsules of biodegradable polylactic acid (PLA). These microcapsules exhibit fiber-particle duality because they are composed of nanofibers suitable for cell attachment while also being easy to handle as particles for direct 3D ...
2011-09-01
Complex Impedance Studies of Electrosprayed and Extruded ...
... Page 66 List of Figures Figure II.A.1 Simple Fuel Cell Model Page 8 ... Carbon Electrodes Figure II.A.1 Simple Fuel Cell Model Page 11. 9 ...
2004-05-05
Cation Involvement in Telomestatin Binding to G-Quadruplex DNA
UK PubMed Central (United Kingdom)
The binding mode of telomestatin to G-quadruplex DNA has been investigated using electrospray mass spectrometry, by detecting the intact complexes formed in ammonium acetate. The mass measurements show...Full Text Available
Delayed Development of Pneumothorax After Pulmonary Radiofrequency Ablation
International Nuclear Information System (INIS)
Acute pneumothorax is a frequent complication after percutaneous pulmonary radiofrequency (RF) ablation. In this study we present three cases showing delayed development of pneumothorax after pulmonary RF ablation in 34 patients. Our purpose is to draw attention to this delayed complication and to propose a possible approach to avoid this major complication. These three cases occurred subsequent to 44 CT-guided pulmonary RF ablation procedures (6.8%) using either internally cooled or multitined expandable RF electrodes. In two patients, the pneumothorax, being initially absent at the end of the intervention, developed without symptoms. One of these patients required chest drain placement 32 h after RF ablation, and in the second patient therapy remained conservative. In the third patient, a slight pneumothorax at the end of the intervention gradually increased and led into tension pneumothorax 5 days ...
2009-05-01
UK PubMed Central (United Kingdom)
BackgroundRadiofrequency ablation (RFA) of tumors by means of internally cooled electrodes (ICE) combined with interstitial infusion of saline may improve clinical results. To date,...Full Text Available
UK PubMed Central (United Kingdom)
Percutaneous radiofrequency ablation is the treatment of choice for osteoid osteoma of the appendicular skeleton. However, difficulties in localizing the lesion in the spine and its proximity to neural...Full Text Available
2009-03-01
Catheter Ablation for Paroxysmal Atrial Fibrillation
... catheter ablation for paroxysmal atrial fibrillation procedure utilizing 3-D mapping and rotational intracardiac echocardiography. This program is ... of the MRI scan and then there's the 3-D image, which is generated from the pixels chosen ...
Cardiovascular magnetic resonance guided electrophysiology studies
UK PubMed Central (United Kingdom)
Catheter ablation is a first line treatment for many cardiac arrhythmias and is generally performed under x-ray fluoroscopy guidance. However, current techniques for ablating complex arrhythmias such...Full Text Available
Energy Technology Data Exchange (ETDEWEB)
In nuclear fuel, in approximately one quarter of the fissions, one of the two formed fission products is gaseous. These are mainly the noble gases xenon and krypton with isotopes of xenon contributing up to 90% of the product gases. These noble fission gases do not combine with other species, and have a low solubility in the normally used uranium oxide matrix. They can be dissolved in the fuel matrix or precipitate in nanometer-sized bubbles within the fuel grain, in micrometer-sized bubbles at the grain boundaries, and a fraction also precipitates in fuel pores, coming from fuel fabrication. A fraction of the gas can also be released into the plenum of the fuel rod. With increasing fission, and therefore burn-up, the ceramic fuel material experiences a transformation of its structure in the 'cooler' rim region of the fuel. A subdivision occurs of the original fuel grains of few microns size into thousands of small grains of sub-micron sizes. Additionally, larger ...
2008-07-01
Calibration free laser-induced breakdown spectroscopy of oxide materials
Energy Technology Data Exchange (ETDEWEB)
The quantitative determination of oxide concentration by laser-induced breakdown spectroscopy is relevant in various fields of applications (e.g.: analysis of ores, concrete, slag). Calibration free laser-induced breakdown spectroscopy and the multivariate calibration are among the methods employed for quantitative concentration analysis of complex materials. We measured the intensity of neutral and ionized atomic emission lines of oxide materials by laser-induced breakdown spectroscopy and we modified the calibration free laser-induced breakdown spectroscopy method to increase the accuracy. The concentration of oxides was obtained by using stoichiometric relations. Sample materials were prepared from oxide powder (Fe{sub 2}O{sub 3}, MgO, CaO) by mixing and pressing. The concentration was 9.8-33.3 wt.% Fe{sub 2}O{sub 3}, 7.6-33.3 wt.% MgO and 33.3-81.2 wt.% CaO for different samples. Nd:YAG laser (wavelength 1064 nm, pulse duration {approx} 6 ns) ...
2010-08-15
Transluminal radio-frequency thermal ablation using a stent-type electrode: an experimental study
Energy Technology Data Exchange (ETDEWEB)
To assess the feasibility of transluminal radiofrequency thermal ablation using a stent-type electrode and to determine, by means of in-vivo and in-vivo animal studies, the appropriate parameters. In-vivo: the radiofrequency electrode used was a self-expandable nitinol stent with 1cm insulated ends. A stent was placed in the portal vein of bovine liver, and ablations at target temperatures of 70, 80, 90, and 100 .deg. C were performed. Ablated sizes were measured longitudinally. In vivo: four mongrel dogs were anesthetized, and a stent was inserted in the common bile duct under fluoroscopic guidance through an ultrasound-guided gall bladder puncture site. The ablation temperature was set at 80 .deg. C, and each dog underwent proximal and distal esophageal ablations lasting 12 minutes. They were sacrificed immediately. In-vivo: ablated sizes showed significant ...
2003-06-01
Search Results - NASA Technical Reports Server
The influence of ablation on stagnation region convective heating for ... and thermal properties of this fiber depend on the fluorination process ... However, these properties are between those of graphite and those of PTFE (Teflon). ...
:z:..... \\ - NASA Technical Report Server (NTRS)
A common reinforced liner material is a cloth formed of PTFE fibers and fiber of ... and ablation protection provided. All of these methods of thermal ..... The influence of fiber content on the microstructures of the composites is ...
8 - NASA Technical Reports Server
The influence of ablation on stagnation region convective heating for ... and thermal properties of this fiber depend on the fluorination process ... However, these properties are between those of graphite and those of PTFE (Teflon). ...
120-MM Gun Tube Erosion Including Surface Chemistry ...
... with dynamic gridding capability to account for material ablation, as well as the addition of energy sources and heat transfer augmentation due to ...
1997-10-01
/ /tLc - NASA Technical Reports Server
Inertial navigation error propagation. Hypersonic entry guidance techniques. Ablation effects on hypersonic aero-. Primary navigation and guidance ...
UK PubMed Central (United Kingdom)
Objectives: To report six month outcome in patients undergoing their first pulmonary vein ablation procedure for idiopathic atrial fibrillation (AF) at a “non-pioneering”...Full Text Available
2005-01-01
Method of defining features on materials with a femtosecond laser
Energy Technology Data Exchange (ETDEWEB)
The invention relates to a pulsed laser ablation method of metals and/or dielectric films from the surface of a wafer, printed circuit board or a hybrid substrate. By utilizing a high-energy ultra-short pulses of laser light, such a method can be used to manufacture electronic circuits and/or electro-mechanical assemblies without affecting the material adjacent to the ablation zone.
2006-05-23
Formation of nano-sized particles of a solid electrolyte by laser ablation
Energy Technology Data Exchange (ETDEWEB)
Nano-sized particles of a lithium ion conductive solid electrolyte, LiTi{sub 2}(PO{sub 4}){sub 3}, were prepared by laser ablation. The obtained particles were ca. 10nm in diameter. X-ray powder diffraction and Raman spectroscopy showed that they were amorphous with local structure similar to the crystalline counterpart. They were crystallized by the heating at ca. 630{sup o}C. (author)
2005-08-26
International Nuclear Information System (INIS)
Efficient and precise ablation of soft tissue is needed for non-invasive dermatological and corneal surgeries. Previous research has revealed that smooth and efficient cutting of certain soft tissues and gelatin is possible using a Free Electron Laser (FEL) with a wavelength of #lambda#=6.45 #mu#m, tuned to the amide-II band of protein. Gelatin ablation experiments have been carried out using a mid-infrared FEL within the waveband #lambda#=5.6-6.7 #mu#m by changing the primary absorbers such as water (#lambda#=6.1 #mu#m) and protein (#lambda#=6.45 #mu#m). The gelatin with 80 wt% water was efficiently ablated by FEL irradiation with the waveband #lambda#=#approx#5.95-6.19 #mu#m. On the other hand, using irradiation within #lambda#=#approx#6.4-6.6 #mu#m, many small bubbles were observed in the irradiated volume, and the gelatin was not ablated but significantly melted. Thus, it was found that the most ...
2003-07-11
Energy Technology Data Exchange (ETDEWEB)
The determination of the banned anabolic substance zeranol and the metabolites taleranol and zearalanone in bovine urine is complicated by the occurrence of the structurally-related mycotoxin zearalenone and the corresponding {alpha}- and {beta}-zearalenol metabolites which possess similar estrogenic properties. A liquid chromatography-negative ion electrospray tandem mass spectrometric method is presented for the confirmatory analysis of all six resorcylic acid lactones ('zeranols') in urine samples using deuterium-labelled internal standards. The method was validated as a confirmatory method for bovine urine samples according to new draft EU guidelines and showed good precision and linearity, and CC{alpha} and CC{beta} values of 0.02-0.30 and <1.0 ng ml{sup -1}, respectively. The applicability was demonstrated by comparing the results of an incurred sample with previous results on the same sample obtained by gas chromatography high ...
2002-11-25
Energy Technology Data Exchange (ETDEWEB)
We demonstrate that the nanoparticle formation during laser ablation of metals by short (of a few tens of ps) laser pulses strongly depends on the concentration of surrounding gas. While, at vacuum conditions, nanoparticle formation shows very ''sharp'' atomic force microscope images of aggregated clusters, following with clear appearance of plasmon resonance on the absorption spectra of deposited films, an addition of gas particles starts to decrease the probability of cluster formation. This process shows a threshold for both helium (33 torr) and xenon (12 torr) above which no surface plasmon resonance and correspondingly no observable nanoparticles on the deposited surfaces were detected. The destruction of nanoparticle formation was attributed to the negative influence of surrounding gas particles on ablated particles aggregation. (orig.)
2010-07-15
The Ames infrared spectral database of isolated, neutral and ionized polycyclic aromatic
1999-01-01
Radiofrequency ablation of lung and liver lesions using CT fluoroscopy
International Nuclear Information System (INIS)
Full text: Tumour ablation with radiofrequency (RF) energy is a relatively new procedure for the treatment of focal malignant disease. At our institution this is currently being used in the treatment of certain liver and lung lesions with the patients involved being enrolled in clinical trials. The poster describes the technique used at our institution for the placement of the radiofrequency ablation electrode using CT fluoroscopy. Criteria for patient selection are included. Complications from the procedure are described, as well as follow up appearances and results. Our results from the treatment of primary and secondary lesions in the liver correlate well with published literature. Treatment is still not as successful as surgical resection but there is significantly less morbidity. Where this method may be appropriate is when the patient is not a candidate for surgical resection. The treatment of colorectal metastases in the lung shows early ...
2002-06-01
UK PubMed Central (United Kingdom)
BackgroundHeterogeneous results for research investigating health-related quality of life (HRQL) in patients undergoing sphincter-ablating procedures for rectal cancer...Full Text Available
2010-08-01
Prognostic determinants for survival after resection/ablation of a large hepatocellular carcinoma
UK PubMed Central (United Kingdom)
Background:Liver resection of large hepatocellular carcinomas (HCC), measuring at least 10 cm remains a controversial debate. Multiple studies on HCCs treated with surgical resection...Full Text Available
2009-06-01
Micropatterned polysaccharide surfaces via laser ablation for cell guidance
Energy Technology Data Exchange (ETDEWEB)
Micropatterned materials were obtained by a controlled laser ablation of a photoimmobilised homogeneous layer of hyaluronic acid (Hyal) and its sulphated derivative (HyalS). The photoimmobilisation was performed by coating the polysaccharide, adequately functionalised with a photoreactive group, on aminosilanised glass substrate and immobilising it on the surface under UV light. Hyal or HyalS photoimmobilised samples were then subjected to laser ablation with wavelengths in the UV regions in order to drill the pattern. Four different patterns with stripes of 100, 50, 25 and 10 {mu}m were generated. A chemical characterisation by attenuated total reflection/Fourier transform infrared (ATR/FT-IR) and time of flight-secondary ions mass spectrometry (TOF-SIMS) confirmed the success of the laser ablation procedure and the presence of alternating stripes of polysaccharide and native glass. The exact dimensions of the stripes were ...
2003-03-03
Metal stenting to resolve post-photodynamic therapy stricture in early esophageal cancer
UK PubMed Central (United Kingdom)
Photodynamic therapy (PDT) is an established endoscopic technique for ablating Barrett’s esophagus with high-grade dysplasia or early-stage intraepithelial neoplasia. The most common clinically...Full Text Available
2011-03-14
UK PubMed Central (United Kingdom)
Cigarette smoke (CS) induces recruitment of inflammatory cells in the lungs leading to the generation of reactive oxygen species (ROS), which are involved in lung inflammation and injury. Nicotinamide...Full Text Available
2008-05-01
UK PubMed Central (United Kingdom)
The murine cytomegalovirus (MCMV) M33 gene is conserved among all betaherpesviruses and encodes a homologue of seven-transmembrane receptors (7TMR) with the capacity for constitutive signaling. Previous...Full Text Available
2008-02-01
Androgens and spermatogenesis: lessons from transgenic mouse models
UK PubMed Central (United Kingdom)
Transgenic mouse models have contributed considerably to our understanding of the cellular and molecular mechanisms by which androgens control spermatogenesis. Cell-selective ablation of the androgen...Full Text Available
2010-05-27
UK PubMed Central (United Kingdom)
BackgroundThere are various treatment options for congenital melanocytic nevus (CMN), including surgical excision, dermabrasions, curettage, laser treatment, chemical peels and cryosurgery....Full Text Available
2009-05-01
'TT ( \\\\ b - NASA Technical Report Server (NTRS)
Inertial navigation error propagation. 153. 100. --. 8. GN-5. Hypersonic entry guidance techniques. 150. 100. 0.8. 9. FM-13. Ablation effects on hypersonic ...
sup 131 I treatment of thyroid papillary carcinoma in a patient with renal failure
Energy Technology Data Exchange (ETDEWEB)
Procedures for {sup 131}I ablation in renal failure are not known. In one patient receiving dialysis, detailed dosimetry and health safety aspects were obtained. The results showed insignificant contamination of equipment, but a surprisingly significant reduction in biologic half-life of {sup 131}I due to efficient dialysis extraction. The data indicate that {sup 131}I ablation can be done safely and easily during dialysis but that much higher {sup 131}I doses must be used to achieve equivalent results to those obtained in patients with normal renal function.
1990-12-15
Energy Technology Data Exchange (ETDEWEB)
To assess the technical feasibility of a newly designed stent-like electrode in rabbits. A stent-like electrode was knitted from a single thread of nitinol wire and interconnected to a generator using similar wire. In order to gauge the extent of radiofrequency ablation (RFA), we measured the depth of the ablated area in cow liver using a combination of 180-sec time intervals and 20- watt power increments. For data processing, Cox regression analysis was used. RFA was also applied to the small intestine of rabbits using this stent-like electrode under six different sets of conditions: 10 watts for 1 min, 10 watts for 2 mins, 20 watts for 1 min, 20 watts for 2 mins, 30 watts for 1 min, and 30 watts for 2 mins. To determine the gross and microscopic findings, six animals were sacrificed immediately after the procedure and the results obtained under the different sets of conditions were correlated. Eight rabbits were monitored for 4 weeks prior to ...
2003-03-01
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study was to investigate the feasibility and the optimal conditions of radiofrequency (RF) ablation by using the stent-type electrode upon the saphenous vein of goats for the endovenous treatment of varicose veins. A self-expandable nitinol stent electrode (6 mm diameter, 2 cm length, cell size; 1.3 x 2 mm) was designed to expose the distal 1 cm segment to allow for contact with the venous wall. The proximal part of the electrode was connected to the RF generator by insulated copper wires located within the stent electrode introducer. Initially, to optimize the power setting, ablation of 6 saphenous veins in 3 goats was performed with power settings of 10, 20 and 30 W. Pull back rate of the electrode was 2 and 4 cm/min for each power level, respectively. The goats were sacrificed 4-6 weeks later and histologic examinations of the saphenous veins were done. For the second part of the experiment, RF ...
2004-10-15
Energy Technology Data Exchange (ETDEWEB)
Purpose: To report on the nephron-sparing, percutaneous ablation of a large renal cell carcinoma by combined superselective embolization and percutaneous radiofrequency ablation. Materials and Methods: A 5 cm renal cell carcinoma of a 43-year-old drug abusing male with serologically proven HIV, hepatitis B and C infection, who refused surgery, was superselectively embolized using microspheres (size: 500 - 700 {mu}m) and a platinum coil under local anesthesia. Percutaneous radiofrequency ablation using a 7F LeVeen probe (size of expanded probe tip: 40 mm) and a 200 Watt generator was performed one day after transcatheter embolization under general anesthesia. Results: The combined treatment resulted in complete destruction of the tumor without relevant damage of the surrounding healthy renal tissue. The patient was discharged 24 hours after RF ablation. No complications like urinary leaks or fistulas ...
2001-11-01
Radiation chloration sulfochloration and sulfooxidation of organic compounds
International Nuclear Information System (INIS)
... halogenation ionizing radiations kinetics radiations reaction kinetics
Energy Technology Data Exchange (ETDEWEB)
Presently, most charge state distributions produced with highly charged ion sources are predicted with models that approximate the ionization process with the Lotz formula. The Lotz ionization cross sections decrease approximately geometrically with increasing charge state except for ions with very few vacancies, for ions with very few electrons, and for electron impact energies which barely exceed the ionization energy. The geometrical decrease causes these models to predict a maximum abundance for most of the charge states, which is only weakly dependent on the charge state. Experimental results, however, yield much higher abundances for ions with an empty M shell than ions with a partly filled M shell. This difference is explained with indirect ionization processes that are neglected by the Lotz approximation, and normally can be neglected for the ionization of the L shell, but ...
2000-02-01
THE RADIO JET INTERACTION IN NGC 5929: DIRECT DETECTION OF SHOCKED GAS
International Nuclear Information System (INIS)
We report on the discovery of kinematic shock signatures associated with a localized radio jet interaction in the merging Seyfert galaxy NGC 5929. We explore the velocity-dependent ionization structure of the gas and find that low-ionization gas at the interaction site is significantly more disturbed than high-ionization gas, which we attribute to a local enhancement of shock ionization due to the influence of the jet. The characteristic width of the broad low-ionization emission is consistent with shock velocities predicted from the ionization conditions of the gas. We interpret the relative prominence of shocks to the high density of gas in the nuclear environment of the galaxy and place some constraints of their importance as feedback mechanisms in Seyferts.
2010-03-10
Metal ion complexation by ionizable crown ethers
Energy Technology Data Exchange (ETDEWEB)
Research conducted since the last progress report includes the synthesis and characterization of twenty three novel proton-ionizable crown ether compounds. Metal ion complexation behavior of new and previously-synthesized proton-ionizable crown ether compounds has been probed by solvent extraction and transport across polymer-supported liquid membranes. The behavior of neutral polyether and proton-ionizable polyether ligands in polymeric membrane electrodes has been assessed. Studies of the use of proton-ionizable crown ethers for separation of lithium isotopes were initiated. Also, the thermodynamics of interactions between alkali metal cations and ionized crown ethers have been probed by titration calorimetry. 10 refs., 1 tab.
1989-09-01
Properties of ZnO thin films prepared by radio-frequency plasma beam assisted laser ablation
International Nuclear Information System (INIS)
Zinc oxide thin films were obtained by laser ablation of a Zn target in oxygen reactive atmosphere, the oxygen being supplied either by a standard gas inlet valve or from a radio-frequency (rf) oxygen plasma. Pt-coated silicon and MgO were used as substrates. The influence of the deposition parameters as laser wavelength (266, 355, 1064 nm), laser fluence (1.5-20 J/cm2) and oxygen pressure (1-60 Pa) was studied. The influence of the rf plasma beam addition on the morphological proprieties of zinc oxide films was particularly investigated, simultaneously with several configurations of the direction of the ablation plasma, the rf plasma beam and the substrate. The obtained films, with thicknesses in the range of 50 nm to 1 ?m have been characterized by atomic force microscopy (AFM), X-ray diffraction (XRD), transmission electron microscopy (TEM).
2005-07-15
International Nuclear Information System (INIS)
Radio-frequency catheter ablation (RFCA) of the distal pulmonary veins is increasingly being used to treat recurrent or refractory atrial fibrillation that doesn't respond to pharmacologic therapy or cardioversion. Successful RFCA of atrial al fibrillation depends on the pre-procedural understanding of the complex anatomy of the distal pulmonary veins and the left atrium. Aim of this parer is to describe the technical main features that characterise the multidetector helical computed tomography in the evaluation of this anatomic region before and after RFCA procedure. The 3D post-processing techniques useful for pre-RFCA planning are straightforward.
Some properties of atomic beam produced by laser induced ablation of Li target
International Nuclear Information System (INIS)
Pulsed atomic beams produced in vacuum by laser induced ablation from a lithium target are analyzed by laser induced fluorescence (LIF). The 1-mixing processes induced in the n = 9, 10 Li Rydberg states by collisions with CO_2 molecules illustrate the application of the method. Resolution is limited by the 1 mm diameter of the probe laser beam. Combining LIF and absorption measurements gives n_L_i as a function of time at various distances from the target surface. The investigation of the Li-C0_2 1-mixing process in a heat pipe oven proved impossible due to the high reactivity of Li with C0_2. This problem was solved by renewing the Li atoms at each laser shot. Values obtained for n = 9, n = 10 are k = 17 x 10"-"8 and 15 x 10"-"8 cc/sec, respectively.
British Library Electronic Table of Contents (United Kingdom)
A rapid and cost-effective assessment was required to provide advice to management on the connectivity between juvenile and adult life cycle stages of Baldchin Groper Choerodon rubescens, a labrid endemic to the west coast of Australia, which has high social value, but relatively low commercial fishery importance. To minimise costs we used laser ablation ICP-MS to analyse levels of a small suite of elements (Ca, Mg, Mn, Cu, Zn, Sr, Rb, Ba and Pb) at the margin (adult phase) and core (juvenile phase) of the same otoliths of adult C. rubescens, collected at ten locations in five management zones. The elemental composition of both otolith margins and cores differed significantly among management zones and in some cases among locations within zones. Similarity of the pattern of among-zone elem...
2011-01-01
Pulsed Radiofrequency Ablation for Residual and Phantom Limb Pain: A Case Series
British Library Electronic Table of Contents (United Kingdom)
Abstract Residual limb pain (RLP) and phantom limb pain (PLP) can be debilitating and can prevent functional gains following amputation. High correlations have been reported between RLP and the stump neuromas following amputation. Many treatment methods including physical therapy, medications, and interventions, have been used with limited success. Pulsed radiofrequency ablation (PRFA) has shown promise in treating neuropathic pain because of the inhibition of evoked synaptic activity. We present 4 amputees who were treated with PRFA after failing conservative management for their RLP and PLP. All 4 patients underwent PRFA and demonstrated at least 80% relief of RLP for over 6 months. One patient reported a complete resolution of phantom sensation while another patient had significantly de...
2010-01-01
The optical and nonlinear optical properties of colloidal solutions of silver obtained by laser ablation in water and ethanol are studied. It is shown that freshly prepared colloids experience a full or partial sedimentation by changing their nonlinear optical properties. Aqueous colloids undergo a partial sedimentation and their nonlinear optical absorption changes to nonlinear optical transmission. The obtained results are interpreted using the Drude model for metal particles taking the particle size into account and can be explained by the sedimentation of larger silver particles accompanied by the formation of a stable colloid containing silver nanoparticles with a tentatively silver oxide shell. The characteristic size of particles forming such a stable colloid is determined and its optical nonlinearity is estimated.
2004-07-01
Effects of small doses of ionizing radiation on human health
Energy Technology Data Exchange (ETDEWEB)
The risks to human health from small doses of ionizing radiation raise questions which remain largely unanswered. This paper begins by explaining the historical background to this subject; it goes on to discuss recent developments and concludes with a personal view of the dose-reponse relationship. (author).
1997-12-01
Effects of small doses of ionizing radiation on human health
International Nuclear Information System (INIS)
The risks to human health from small doses of ionizing radiation raise questions which remain largely unanswered. This paper begins by explaining the historical background to this subject; it goes on to discuss recent developments and concludes with a personal view of the dose-reponse relationship. (author).
1997-01-01
UK PubMed Central (United Kingdom)
Although skin is usually exposed during human exposures to ionizing radiation, there have been no thorough examinations of the transcriptional response of skin fibroblasts and keratinocytes...Full Text Available
2009-07-01
Untitled - NASA Technical Report Server (NTRS)
is 10 seconds for P-type silicon material,. TO ,. In ordkr to determine the effects of unbalanced ionization between the two ...
Results from a Bragg Curve Spectrometer
Energy Technology Data Exchange (ETDEWEB)
The Bragg Curve Spectrometer (BCS) is an ionization chamber long enough to stop particles of interest. Particles enter through the cathode window and leave an ionization track parallel to the electric field. The ionization electrons drift through a Frisch grid and are collected on an anode. The anode current, as a function of time, is split and used as input for two amplifiers, one with a long integration time constant for energy measurement, and one with a short time constant to pick off the maximum ionization or Bragg peak. The Bragg peak, which is proportional to the nuclear charge, is used for particle identification. We have constructed and tested several versions of the BCS. The results are described.
1984-01-01
Results from a Bragg Curve Spectrometer
International Nuclear Information System (INIS)
The Bragg Curve Spectrometer (BCS) is an ionization chamber long enough to stop particles of interest. Particles enter through the cathode window and leave an ionization track parallel to the electric field. The ionization electrons drift through a Frisch grid and are collected on an anode. The anode current, as a function of time, is split and used as input for two amplifiers, one with a long integration time constant for energy measurement, and one with a short time constant to pick off the maximum ionization or Bragg peak. The Bragg peak, which is proportional to the nuclear charge, is used for particle identification. We have constructed and tested several versions of the BCS. The results are described.
1984-10-22
British Library Electronic Table of Contents (United Kingdom)
Abstract Ionizing radiation is a ubiquitous feature of the Cosmos, from exogenous cosmic rays (CR) to the intrinsic mineral radioactivity of a habitable world, and its influences on the emergence and persistence of life are wide-ranging and profound. Much attention has already been focused on the deleterious effects of ionizing radiation on organisms and the complex molecules of life, but ionizing radiation also performs many crucial functions in the generation of habitable planetary environments and the origins of life. This review surveys the role of CR and mineral radioactivity in star formation, generation of biogenic elements, and the synthesis of organic molecules and driving of prebiotic chemistry. Another major theme is the multiple layers of shielding of planetary surfaces from th...
2011-01-01
Ionization and recombination rates in non-Maxwellian plasmas
The ionization, excitation, and radiative recombination rates for highly stripped ions are cal- culated with Maxwellian and non-Maxwellian electron distribution functions of the type Cmexp(-vm/wm) (2<=m<=5) as encountered in laser-heated plasmas and certain types of turbulent plasmas. The direct-radiative-recombination rates are found to decrease by at most 30% as m is increased from 2 to 5. On the other hand, the ionization and excitation rates are found to be strongly reduced if the transition energy ? exceeds twice the local temperature kBTe. The effect of this on the distribution of energy levels and degrees of ionization in laser-produced plasmas could be important.
1986-08-01
Bragg-curve spectroscopy detector
Energy Technology Data Exchange (ETDEWEB)
In an ionization chamber with the electric field parallel to the particle trajectories, the time dependence of the anode signal contains all the information about the energy and the nuclear charge of the ionizing particle. By proper pulse shaping with a long and a short time constant the total ionization charge and the ionization charge integrated around the Bragg maximum, respectively, can be obtained. The former signal is proportional to the total energy, whereas the latter allows the nuclear charge to be deduced directly. An energy resolution of 0.4% and a Z resolution ..delta..Z/Z = 1/82 was achieved for 130 MeV /sup 32/S ions and argon-methane as the stopping medium.
1982-02-01
Standards and guidances for limiting ionizing radiation exposure
Energy Technology Data Exchange (ETDEWEB)
This chapter is concerned with standards and guidances for limiting radiation exposures. It is divided into three sections, each of which has several parts. Section 1: Ionizing Radiation -- Standards and Guidances Applicable to the Public: Part A, Radiation Protection Standards; Part B, Environmental Radiation Standards; Part C, Exempt Levels of Radioactivity; Part D, Protective Action Guides for Accidents. Section 2: Ionizing Radiation -- Standards Applicable to the Workplace. Section 3: Medical and Other Standards.
1992-12-31
International Nuclear Information System (INIS)
Effect of single and chronic irradiation on factors of hamsters natural immunity such as complement, lysozyme and antibodies in norm and in the cestode invasion has been investigated. Significant phase changes in the complement activity level, lysozyme content and specific antibodies tite have been shown to occur in hamster blood under the influence of ionizing radiation. Cestode invasion in irradiated host organism increases the negative effect of ionizing radiation on the hamster immyne system.
1994-01-01
A simple, high efficiency, negative surface ionization source
Energy Technology Data Exchange (ETDEWEB)
A spherical-geometry, self-extraction negative ion source has been designed and fabricated. The source utilizes direct surface ionization to form negative ion beams resulting from interactions between high electron affinity gaseous elemental or molecular materials and a negatively biased, spherical-sector LaB{sub 6} surface ionizer maintained at {similar to}1300 K. The design features of this source and principles upon which the source is based are discussed in this report.
1992-04-01
X-ray ablation measurements and modeling for ICF applications
Energy Technology Data Exchange (ETDEWEB)
X-ray ablation of material from the first wall and other components of an ICF (Inertial Confinement Fusion) chamber is a major threat to the laser final optics. Material condensing on these optics after a shot may cause damage with subsequent laser shots. To ensure the successful operation of the ICF facility, removal rates must be predicted accurately. The goal for this dissertation is to develop an experimentally validated x-ray response model, with particular application to the National Ignition Facility (NIF). Accurate knowledge of the x-ray and debris emissions from ICF targets is a critical first step in the process of predicting the performance of the target chamber system. A number of 1-D numerical simulations of NIF targets have been run to characterize target output in terms of energy, angular distribution, spectrum, and pulse shape. Scaling of output characteristics with variations of both target yield and hohlraum wall thickness are also described. ...
1996-09-01
Plasma lens formation in e{gamma} and {gamma}{gamma} colliders
Energy Technology Data Exchange (ETDEWEB)
The beams in electron linear colliders can be converted to nearly monochromatic photon beams by means of Compton backscattering of laser photons. The electron beams must then be diverted from the interaction point by some means, the best of which seems to be a plasma lens. This paper describes the constraints on the plasma lens in this application and shows how the ablation of solid hydrogen pellets might be able to produce plasmas to satisfy these constraints. ((orig.)).
1995-02-01
International Nuclear Information System (INIS)
The purpose of this study was to compare a double freeze-thaw protocol to a triple freeze-thaw protocol for pulmonary cryoablation utilizing an in vivo porcine lung model. A total of 18 cryoablations were performed in normal porcine lung utilizing percutaneous technique with 9 each in a double- (10-5-10) and triple-freeze (3-3-7-7-5) protocol. Serial noncontrast CT images were obtained during the ablation. CT imaging findings and pathology were reviewed. No imaging changes were identified during the initial freeze cycle with either protocol. However, during the first thaw cycle, a region of ground glass opacity developed around the probe with both protocols. Because the initial freeze was shorter with the triple freeze-thaw protocol, the imaging findings were apparent sooner with this protocol (6 vs. 13 min). Also, despite a shorter total freeze time (15 vs. 20 min), the ablation zone identified with the triple freeze-thaw protocol was not ...
2010-12-01
UK PubMed Central (United Kingdom)
Although matrix metalloproteinase-9 (MMP-9) is involved in cardiomyocytes contractility dysfunction, tissue inhibitor of metalloproteinase-4 (TIMP-4) mitigates the effect of MMP-9, and proteinase-activated...Full Text Available
2010-07-01
Results from a Bragg Curve Spectrometer
International Nuclear Information System (INIS)
The Bragg Curve Spectrometer (BCS) is an ionization chamber long enough to stop particles of interest. Particles enter through the cathode window and leave an ionization track parallel to the electric field. The ionization electrons drift through a Frisch grid and are collected on an anode. The anode current, as a function of time, is proportional to the specific ionization along the track. The preamp output is split and used as input for two amplifiers, one with a long integration time constant for energy measurement, and one with a short time constant to pick off the maximum ionization or Bragg peak. The Bragg peak, which is proportional to the nuclear charge, is used for particle identification. Several versions of the BCS have been constructed and tested. Test results, detector characteristics and some design problems are discussed.
1984-10-01
International Nuclear Information System (INIS)
In laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS), the properties of laser-generated aerosols, such as size and composition, are crucial for matrix-independent quantification. In this study, the aerosol particle morphology and elemental composition generated by two state-of-the-art laser systems (ArF excimer nanosecond-UV laser and Ti:sapphire femtosecond-IR laser) were investigated by electron microscopic techniques. Electrostatic sampling of the aerosols directly onto transmission electron microscopy (TEM) grids allowed us to study the morphology and elemental composition of the aerosols using TEM and TEM-EDX (energy dispersive X-ray spectroscopy) analyses, respectively. The results of the electron microscopic studies were finally compared to the LA-ICPMS signals of the main matrix components. The investigations were carried out for non-conducting materials (glass and zircon), metallic samples (steel and brass) and semiconductors ...
A magnetically levitated electrode ionization chamber of the noncontact measurement type
Energy Technology Data Exchange (ETDEWEB)
A new type of ionization chamber with levitated electrode has been developed. In this ionization chamber, an ion-collection electrode levitates in the air without getting any physical support from the insulator. The electrode is charged by an electrostatic charger without physical contact. The charge of the electrode is read out at a Faraday cage periodically at a given time interval without physical contact. Because its electrode levitates, the ionization chamber produces no background current caused by leaks or piezo current. In addition, as the charging of its electrode and the read-out of its charge are carried out without physical contact, no irregular charge or contact potential difference due to the chattering between electrode and contact point occurs. Through experiments, it was found that this ionization chamber was able to measure the {gamma}-ray dose such as the environmental radiation with ...
2002-04-01
Energy Technology Data Exchange (ETDEWEB)
We have measured the K-shell ionization probability across the 6.06-MeV resonance in /sup 88/Sr(p,p/sub 0/) where the resonance width is large compared to the energy transferred to the electron. The results are found to agree quantitatively with the theory developed by Blair and Anholt. The effect of the time delay on the ionization probability, introduced by the nuclear scattering at the resonance energy, is discussed.
1982-09-01
A measurement of the cross section for electron impact ionization of Ar"2"+, Kr"2"+ and Xe"2"+
International Nuclear Information System (INIS)
The crossed electron-ion beams technique was used to measure absolute cross sections for single ionization of Ar"2"+, Kr"2"+ and Xe"2"+ ions at electron energies ranging from threshold to 2000 eV. In contrast to some previous measurements, the metastable contents of the ion beams were small even in the case of Xe"2"+. All measured cross section curves show significant contributions from excitation-autoionization and possibly direct ionization of inner-shell electrons. There is evidence for resonance-excitation-double-autoionization in the case of Xe"2"+. (author).
Toward a theory of the initiation of cancer by ionizing radiation: the twin doublet pair model
Models are proposed which explain the mechanism of action on a molecular level for the initiation of cancer by electrons or alpha particles. (ACR)
1980-01-01
International Nuclear Information System (INIS)
Portuguese Sep-Oct 1996 p. 571 Brazil Campos, Patricia Sao Paulo
Photoelectron resonance capture ionization (PERCI) is a soft and sensitive ionization method, based on the attachment of low-energy (<1 eV) photoelectrons to organic analyte molecules. PERCI has been developed in our laboratory for the real-time analysis of organic particles by mass spectrometry, and is employed here to monitor the heterogeneous reaction of ozone with oleic acid. Simplified identification of the reaction products is possible as a result of the soft nature of PERCI, giving predominantly the [M--H](-) ions. The major particle-phase products are identified as: 1-nonanal, nonanoic acid, 9-oxononanoic acid, and azelaic acid, consistent with proposed mechanisms. New insight into this well-studied heterogeneous reaction is gained as additional minor particle-phase products, consistent with the Criegee mechanism, are readily detected. PMID:15468105
2004-01-01
... that are hosts of tephritids (Diptera) and sweetpotatoes, Ipomea batatas (L.) Lam, at risk of carrying three ... ...
Extreme resistance of bdelloid rotifers to ionizing radiation
UK PubMed Central (United Kingdom)
Rotifers of class Bdelloidea are common invertebrate animals with highly unusual characteristics, including apparently obligate asexuality, the ability to resume reproduction after desiccation at any...Full Text Available
2008-04-01
Development of ambient sampling chemi/chemical ion source with dielectric barrier discharge
British Library Electronic Table of Contents (United Kingdom)
The development of a new configuration of chemical ionization (CI)-based ion source is presented. The ambient air containing the gaseous sample is sniffed into an enclosed ionization chamber which is of sub-ambient pressure, and is subsequently mixed with metastable species in front of the ion inlet of the mass spectrometer. Metastable helium atoms (He*) are used in this study as the primary ionizing agents and are generated from a dielectric barrier discharge (DBD) source. The DBD is powered by an AC high-voltage supply and the configuration of the electrodes is in such a way that the generated plasma is confined within the discharge tube and is not extended into the ionization chamber. The construction of the ion source is simple, and volatile compounds released from the bulky sample can...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
An alternative utilization is presented for the gaseous ionization chamber in the detection of energetic heavy ions, which is called Bragg Curve Spectroscopy (BCS). Conceptually, BCS involves using the maximum data available from the Bragg curve of the stopping heavy ion (HI) for purposes of identifying the particle and measuring its energy. A detector has been designed that measures the Bragg curve with high precision. From the Bragg curve the range from the length of the track, the total energy from the integral of the specific ionization over the track, the dE/dx from the specific ionization at the beginning of the track, and the Bragg peak from the maximum of the specific ionization of the HI are determined. This last signal measures the atomic number, Z, of the HI unambiguously.
1981-05-01
Are There Enough Ionizing Photons to Reionize the Universe by z=6?
An estimate for the number of ionizing photons per baryon as a function of redshift is computed based on the plausible extrapolation of the observed galaxy UV luminosity function and the latest results on the properties of the escape fraction of ionizing radiation. It is found that, if the escape fraction for low mass galaxies (Mtot<10^{11}Msun) is assumed to be negligibly small, as indicated by numerical simulations, then there are not enough ionizing photons to reionize the universe by z=6 for the cosmology favored by the WMAP 3rd year results, while the WMAP 1st year cosmology is marginally consistent with the reionization requirement. The escape fraction as a function of galaxy mass would have to be constant to within a factor of two for the whole mass range of galaxies for reionization to be possible within the WMAP 3rd year cosmology.
2007-01-01
The surface modification of tooth dentine with a Free Electron Laser (FEL)
International Nuclear Information System (INIS)
Free Electron Laser (FEL) with the wide wavelength tunability has been developed and used for various applications. The FEL gives high efficiency for the photo-induced ablation when the laser is tuned to an absorption maximum of the target. The FEL was tuned to 9.4 #mu#m, which is an absorption maximum of phosphoric acid ion, a known major component of dentine. The FEL pulse length was several ps. The average output power was varied from 5 to 20 mW by filters. The change of irradiated dentine surface was analyzed by mass spectroscopy and Energy Dispersive X-ray (EDX) spectroscopy. Positive ions which correspond to Na"+, CO_3"+ and many phosphoric acid ions were measured. It was found that atomic ratio of P/Ca had reduced from 0.65-0.60. The atomic ratio of P/Ca, however had not changed with irradiation by Er:YAG laser (2.9 #mu#m), or CO_2 laser (10.6 #mu#m). These results indicate the selective ablation of phosphoric acid ion by the 9.4 mm FEL ...
1998-09-02
Energy Technology Data Exchange (ETDEWEB)
Tetracycline is an antibiotic that absorbs ultraviolet light at 355 nm and preferentially binds to atherosclerotic plaque both in vitro and in vivo. Tetracycline-treated human cadaveric aorta was compared with untreated aorta using several techniques: absorptive spectrophotometry; and tissue uptake of radiolabeled tetracycline, which showed 4-fold greater uptake by atheroma than by normal vessel. In addition, intravenous tetracycline administered to patients undergoing vascular surgery demonstrated characteristic fluorescence in surgically excised diseased arteries. Because of tetracycline's unique properties, the authors exposed tetracycline-treated and untreated aorta to ultraviolet laser radiation at a wavelength of 355 nm. They found enhanced ablation of tetracycline-treated atheroma compared with untreated atheroma. The plaque ablation caused by ultraviolet laser radiation was twice as extensive in tetracycline-treated vs ...
1985-05-01
British Library Electronic Table of Contents (United Kingdom)
We found that the androgenic gland (AG) of Macrobrachium rosenbergii possesses three cell types. Type I cells are small polygonal shaped-cells (13.4 mu m in diameter), stain strongly with hematoxylin-eosin (H&E), have abundant multilayered rough endoplasmic reticulum (rER), and nuclei containing mostly heterochromatin. Type II cells are slightly larger (18.6 mu m in diameter), stain lightly with H&E, have rER with dilated cisternae, and nuclei containing mostly euchromatin. Type III cells (previously undescribed) are similar in size and shape to type I cells, but the cytoplasm is unstained and they have a high amount of smooth endoplasmic reticulum (sER) and mitochondria with tubular cristae. Bilateral eyestalk-ablation resulted in AG hypertrophy with a proliferation and predominance of ty...
2011-01-01
Uranium isotopic assay instrument
International Nuclear Information System (INIS)
Full text: The isotopic assay instrument under development at Pacific Northwest National Laboratory (PNNL) is capable of rapid prescreening to detect small and rare particles containing high concentrations of uranium in a heterogeneous sample. The isotopic measurement concept is based on laser vaporization of solid samples followed by sensitive isotope-specific detection using either uranium atomic fluorescence emission or uranium atomic absorbance. Both isotopes are measured concurrently, following a single ablation laser pulse using two external-cavity violet diode lasers. The simultaneous measurement of both isotopes enables the correlation of the fluorescence and absorbance signals on a shot-to-shot basis. This measurement approach demonstrated negligible channel crosstalk between isotopes. Scanning the heterogeneous samples provides high-resolution imagery of sample isotopic fluorescence and absorbance. Isotopically selective excitation of uranium vapor also ...
2006-10-16
International Nuclear Information System (INIS)
Original investigations of ablation of minerals, fullerene-like compounds, polymers and complicated biological macromolecules under the action of submillimeter radiation of the free-electron laser (FEL) developed and built at Budker Institute of Nuclear Physics [V.P. Bolotin et al., First experiments on high-power Novosibirsk terahertz free-electron laser, Budker INP, 2005, p. 37
2007-05-21
International Nuclear Information System (INIS)
The purpose of this paper is to report the personal experience with helical CT evaluation of hepatocellular carcinoma treated with various percutaneous interventional procedures. From December 1996 to September 1998 it were examined with helical CT 41 patients (73 nodules in all) with hepatocellular carcinoma treated with percutaneous ablation therapies: conventional ethanol injection in 18 subjects (31 nodules), one-shot ethanol injection 3 (8 nodules), radiofrequency thermal ablation in 16 (25 nodules), and combined chemo embolization and ethanol injection in 4 (9 nodules). CT performed was 4-27 days after the last session, acquiring biphasic volumetric images in 14 patients and triphasic volumetric images in 27. A second treatment with subsequent CT study was performed for 28 lesions; 15 underwent 3 serial studies and 6 underwent 4 studies. Compared with pretreatment findings, the diameter was unchanged in 62% of the nodules and increased in ...
1999-12-01
Method for the approximate solution of a two-phase stefan problem with reverse motion of the front
Determination of the trajectory of a phase transition front moving in a forward or reverse direction is reduced to the solution of an ordinary differential equation. A numerical check of the results shows the method to be highly accurate. The method was used recently over a period of several years to solve various problems connected with the thawing of frozen rocks and their refreezing; among the problems considered was that of the ablation of rocks during the channeling of well, in which the method invariably proved its effectiveness. This furnishes a basis for recommending it for broader usage.
1988-03-01
Energy Technology Data Exchange (ETDEWEB)
Clinical studies have proved the effectiveness of local ablading methods in pations with non-resectable liver metastases of a colorectal carcinoma. RF ablation and LITT are a potentially curative therapy option and an alternative to systemic chemotherapy; the latter is carried out primarily for reducing tumour size with the goal of secondary resectability. The number of R0-sesectable metastases can be enhanced by a combined therapy of surgery and local ablading methods, e.g. by preoperative, intraoperative or postoperative ablasion of further non-resectable tumours during surgery. Systemic chemotherapy combined with surgery as an adjuvant method is not recommended unless in cases of non-abladable tumour recidivation. Currently, systemic chemotherapy is used as a neo-adjuvant therapy for tumour size reduction with the goal of secondary resectability or, in case of inoperability, local ablation. (orig.) [German] Abladierende Verfahren. Klinische ...
2003-03-01
Radiofrequency Ablation of Intrahepatic Cholangiocarcinoma: Preliminary Experience
International Nuclear Information System (INIS)
The purpose of this study was to evaluate the safety and efficacy of percutaneous ultrasound (US)-guided radiofrequency ablation (RFA) in patients with intrahepatic cholangiocarcinoma (ICCA) in a small, nonrandomized series. From February 2004 to July 2008, six patients (four men and two women; mean age 69.8 years [range 48 to 83]) with ICCA underwent percutaneous US-guided RFA. Preintervetional transarterial embolization was performed in two cases to decrease heat dispersion during RFA in order to increase the area of ablation. The efficacy of RFA was evaluated using contrast-enhanced dynamic computed tomography (CT) 1 month after treatment and then every 3 months thereafter. Nine RFA sessions were performed for six solid hepatic tumors in six patients. The duration of follow-up ranged from 13 to 21 months (mean 17.5). Posttreatment CT showed total necrosis in four of six tumors after one or two RFA sessions. Residual tumor was observed in two ...
2010-08-01
Energy Technology Data Exchange (ETDEWEB)
A great deal of current research is directed to finding a way to minimize thermal injury in the esophagus during radiofrequency catheter ablation of the atrium. A recent clinical study employing a cooling intraesophageal balloon reported a reduction of the temperature in the esophageal lumen. However, it could not be determined whether the deeper muscular layer of the esophagus was cooled enough to prevent injury. We built a model based on an agar phantom in order to experimentally study the thermal behavior of this balloon by measuring the temperature not only on the balloon, but also at a hypothetical point between the esophageal lumen and myocardium (2 mm distant). Controlled temperature (55 {sup 0}C) ablations were conducted for 120 s. The results showed that (1) the cooling balloon provides a reduction in the final temperature reached, both on the balloon surface and at a distance of 2 mm; (2) coolant temperature has a significant effect ...
2008-02-21
miR-9 and let-7g enhance the sensitivity to ionizing radiation by suppression of NF?B1
UK PubMed Central (United Kingdom)
The activation of nuclear factor-kappa B1 (NFκB1) in cancer cells may confer resistance to ionizing radiation (IR). To enhance the therapeutic efficiency of IR in lung cancer, we screened for...Full Text Available
2011-05-31
International Nuclear Information System (INIS)
The cross section database for electron impact excitation and electron impact ionization for hydrogen beam kinetic energies greater than 100 eV was considered, giving for each particular process a reference to a recommended publication of cross sections, as well as the accuracy or estimated accuracy. The work is motivated by the application of neutral beam injection in magnetic confinement devices, such as large tokamaks. 9 refs, 2 figs.
1989-07-01
Tumorigenic and tumoricidal actions of ionizing radiations
Energy Technology Data Exchange (ETDEWEB)
The book is divided into two approximately equal parts. The first four chapters are relatively lengthy and cover the basic principles of radiation biology, carcinogenesis and therapy, along with a brief introduction to radiological physics to orient the reader without background in this specialized related discipline. The remainder consists of twenty-four relatively brief chapters, each covering the radiation biology of a specific organ, tissue, or systems tissues, with emphasis on the tumorigenic and tumoricidal action of ionizing radiations.
1983-01-01
Theoretical transition energies, lifetimes and fluorescence yields of multiply ionized silicon
Energy Technology Data Exchange (ETDEWEB)
Theoretical x-ray transition energies, lifetimes and partial multiplet fluorescence yields are presented for all spectroscopic terms of electron configurations with a single K-shell vacancy and varying number of electrons in the L-shell and M/sub 1/-subshell for multiply-ionized silicon. 9 tables.
1982-01-01
The semiclassical approximation for L- and M-shell Coulomb ionization by heavy charged particles
International Nuclear Information System (INIS)
The semiclassical approximation with straight-line trajectories is applied to the Coulomb ionization of K, L and M shells by heavy charged particles. The calculational aspects are discussed in detail. Scaling relations for the experimentally relevant quantities are derived. The theoretical predictions are compared with experiment. The relation of the present work to the earlier results of the semiclassical approximation and partial-wave Born approximation is discussed in detail. (author).
Radioanalytical chemistry. Vol. 2
International Nuclear Information System (INIS)
This volume of the monograph covers the following topics: activation analysis, non-activation interaction analysis (elastic scattering of charged particles, absorption and backscattering of beta radiation and photons, radionuclide X-ray fluorescence analysis, thermalization, scattering and absorption of neutrons, use of ionization caused by nuclear radiation, use of ionization by alpha or beta radiation for the measurement of pressure, density and flow rate of gases), and automation in radioanalytical chemistry. (P.A.).
1989-01-01
Mechanisms of EBW HE initiation
Exploding bridgewire (EBW) initiation of high explosives (HE) has been used for many years without a clear understanding of the mechanisms involved. Evidence indicates that the shock pressures produced by the EBW may be insufficient for direct initiation and that the electric field about the wire at the time of burst ionizes the surface of the HE. We hypothesize that the ionization pre-sensitizes the HE so that a weak shock can then initiate a detonation wave. 13 refs., 7 figs.
1991-05-15
Organic molecules are a significant and highly varied component of atmospheric aerosols. Measurement of aerosol composition and improvements in our understanding of the complex chemistry involved in their formation and aging are being aided by innovations in soft ionization aerosol MS. (To listen to a podcast about this feature, please go to the Analytical Chemistry multimedia page at pubs.acs.org/page/ancham/audio/index.html.). PMID:21275431
2011-01-24
International Nuclear Information System (INIS)
A patent is claimed for the invention of a hardening (ionizing radiation resistance) process for MOS type components and CMOS or bipolar type components. The ionizing radiation effect on those systems is the electron-hole pair production, which induces interference phenomena. The MOS main structure is successively composed of a silicon substrate layer, a layer of an irradiation resistant material and a layer of partially monocrystalline silicon.
1988-12-09
Experimental research of spontaneous evolution from ultracold rydberg atoms to plasma
International Nuclear Information System (INIS)
The spontaneous evolution from ultracold Rydberg atoms to plasma is investigated in a caesium MOT by using the method of field ionization. The plasma transferred from atoms in different Rydberg states (n=22-32) are obtained experimentally. Dependence of the threshold time of evolving to plasma and the threshold number of initial Rydberg atoms on the principal quantum number of initial Rydberg states is studied. The experimental results are in agreement with hot-cold Rydberg-Rydberg atom collision ionization theory. (authors)
2008-04-01
Continuous control of ionization wave chaos by spatially derived feedback signals
In the positive column of a neon glow discharge, two different types of ionization waves occur simultaneously. The low-dimensional chaos arising from the nonlinear interaction between the two waves is controlled by a continuous feedback technique. The control strategy is derived from the time-delayed autosynchronization method. Two spatially displaced points of observation are used to obtain the control information, using the propagation characteristics of the chaotic wave.
1997-01-01
Cesium ion desorption ionization with Fourier transform mass spectrometry
International Nuclear Information System (INIS)
Cesium ions (Cs"+) are used for the production of the feed ions necessary to obtain Fourier transform mass spectra (FTMS). The molecule chosen for the initial study of this Cs"+ desorption ionization (DI-FTMS) was vitamin B-12 because of its nonvolatile, thermally labile character. 21 references.
Energy Technology Data Exchange (ETDEWEB)
A physical explanation is given for the positive differential voltage-current characteristic seen at low current in weakly ionized, low-pressure positive column discharges in argon/mercury gas mixtures. {copyright} {ital 1996 The American Physical Society.}
1996-07-01
Parametric Resonance Ionization Cooling and Reverse Emittance Exchange for Muon Collider
Energy Technology Data Exchange (ETDEWEB)
Two methods to cool muon beams deeply below the limit conventionally established for the ionization cooling are proposed. In Phase Ionization Cooling (PIC), the beam is focused at wedge absorber plates each half of particle oscillation period by imposing a weak parametric resonance along the beam path. The resonance growth of particle amplitude is surmounted by the ionization cooling. At optimum, such arrangement results in reduction of each of two transverse emittances by an order of value in addition to the preceding 6D ionization cooling. Next, resonance focusing and transverse cooling can be continued in the regime of a fast Reverse Emittance Exchange (REMEX). Here, the sign of the absorber wedge is opposite to PIC while the dispersion increased. REMEX to be accompanied by the bunch lengthening and acceleration in order to maintain the relative energy spread at an appropriate level. The limitations ...
2005-09-18
British Library Electronic Table of Contents (United Kingdom)
The photoelectron resonance capture ionization (PERCI) of cysteine (Cys) and small gas-phase neutral peptides that contain the Cys residue (Cys-Gly, g-Glu-Cys, and glutathione (g-Glu-Cys-Gly)) is reported. At an ionization energy less than 1eV two types of dissociative electron attachment ionization were observed for Cys: hydrogen atom loss, resulting in formation of the ion [Cys-H]-, and dissociation of the CH2-SH bond, resulting in formation of the ion [SH]-. The presence of these ions suggests that both the p*(-CO2H) and *(C-S) orbitals can act as low energy electrophores on Cys. This ionization trend was observed for the dipeptides Cys-Gly and g-Glu-Cys as well as glutathione, with evidence that dissociation of the CH2-SH bond in these peptides can also result in ions of the form [M-SH...
2009-01-01
We compare the predictions of four different algorithms for the distribution of ionized gas during the Epoch of Reionization. These algorithms are all used to run a 100 Mpc/h simulation of reionization with the same initial conditions. Two of the algorithms are state-of-the-art ray-tracing radiative transfer codes that use disparate methods to calculate the ionization history. The other two algorithms are fast but more approximate schemes based on iterative application of a smoothing filter to the underlying source and density fields. We compare these algorithms' resulting ionization and 21 cm fields using several different statistical measures. The two radiative transfer schemes are in excellent agreement with each other (with the cross-correlation coefficient of the ionization fields >0.8 for k 0.6 for k < 1 h/Mpc). When used to predict the 21cm power spectrum at different times during ...
2010-01-01
British Library Electronic Table of Contents (United Kingdom)
We have demonstrated that, with simple pH adjustment, volatile drugs such as methamphetamine, amphetamine, 3,4-methylenedioxymethamphetamine (MDMA), ketamine, and valproic acid could be analyzed rapidly from raw biofluid samples (e.g. urine and serum) without dilution, or extraction, using atmospheric pressure ionization. The ion source was a variant type of atmospheric pressure chemical ionization (APCI) that used a dielectric barrier discharge (DBD) to generate the metastable helium gas and reagent ions. The sample solution was loaded in a disposable glass pipette, and the volatile compounds were purged by nitrogen gas to be reacted with the metastable helium gas. The electrodes of the DBD were arranged in such a way that the generated glow discharge was confined within the discharge tub...
2009-01-01
International Nuclear Information System (INIS)
A high-precision Li isotope analysis was developed for determining the Li"+ ion emitted from lithium phosphate as an ion source material by a Re double-filament ionization method in the thermal ionization mass spectrometry. In this method, Li isotopic fractionation is distinctly less sensitive to the filament temperature than those in the previous methods, and stable and high ion beam intensity of more than 8 x 10"-"1"1 A for "7Li is obtained. These advantages in determining the "7Li/"6Li ratio result in the analytical reproducibility of 0.26 per mille (1#sigma#). Furthermore, the sample preparation is simple and the low temperature (850degC) required by this method ensures the analysis of the isotopic composition of small amounts of Li with less influence of Li contamination to the sample, compared with the previous methods. (author).
Photoelectron resonance capture ionization mass spectrometry of fatty acids in olive oil
British Library Electronic Table of Contents (United Kingdom)
Photoelectron resonance capture ionization (PERCI) mass spectrometry has been developed for the direct online analysis of organics, including lipids. Analysis is conducted without the need for sample preparation or chemical derivatization such as methylation, foregoing the use of harmful or toxic chemicals. PERCI is currently being adapted towards the analysis of edible oils. Herein, as a proof of principle of the simplicity and potential utility of this method towards the analysis of edible oils, we present the analysis of the prevalent fatty acids (FA) in Tuscan extra-virgin olive oil along with triolein and linolenic acid (LNA) standards. Ionization of olive oil results in little fragmentation of the prevalent FA, which are measured as their molecular ions, [FA-H]-. The relative concent...
2006-01-01
Measurement of electron-impact single-ionization cross sections of Ar"8"+
International Nuclear Information System (INIS)
A crossed-electron-ion-beam experiment was used to measure the total ionization cross section for Ar"8"+ in the energy range from 50 to 600 eV. The present results are roughly in agreement with the previous measurements of Defrance et al. [Nucl. Instrum. Methods Phys. Res. B 23, 256 (1987)] above 450 eV. However, the present measurements show a significant contribution below the threshold for direct ionization. The present measurements agree with the distorted-wave calculations of Pindzola et al. [Phys. Rev. A 41, 1375 (1990)] when 3% of the incident ion beam is assumed to be in metastable states and excitation autoionization from metastable states is included.
British Library Electronic Table of Contents (United Kingdom)
Abstract We use Smoothed Particle Hydrodynamics to simulate the formation of a massive (106-M-) stellar cluster system formed from the gravitational collapse of a turbulent molecular cloud. We investigate the hierarchical clustering properties of our model system and we study the influence of the photoionizing radiation produced by the system's multiple O-type stars on the evolution of the protocluster. We find that dense gas near the ionizing sources prevents the radiation from eroding the filaments in which most of the star formation occurs and that instead, ionized gas fills pre-existing voids and bubbles originally created by the turbulent velocity field.
2011-01-01
Ion-induced M X-ray emission from heavy lanthanides
International Nuclear Information System (INIS)
Thick targets of several heavy lanthanide (Ho-Lu) compounds were bombarded by protons and "3He ions of 3 MeV/amu, and M_#alpha# and M_#beta# X-rays were measured with a crystal spectrometer. Ionization probabilities of the N-shell for zero impact parameter were obtained from the X-ray intensity ratio for proton and "3He ion impacts. A shell dependence of the ionization probability was found in a scaling plot. X-ray spectra of lanthanide compounds were compared and no chemical effect was observed. This result is considered to be due to the fact that the main component of M_#alpha# and M_#beta# lines is for radiative transition after the refilling of the 4f orbit (3d"-"14f"n"+"1 #-># 4f"n) where n denotes the number of 4f electrons of the target atom before ionization. (orig.).
1987-12-01
British Library Electronic Table of Contents (United Kingdom)
High molecular weight products of the ozonolysis reaction of particle-phase 9-octadecenoic acid (oleic acid) have been studied by photoelectron resonance capture ionization (PERCI) mass spectrometry (MS). Oleic acid particles ( Formula Not Shown , Formula Not Shown ) were reacted with ozone (1.8x10-4atm) in a flow reactor at reaction times of 8 and 23s. Particles were sampled on-line with a differentially pumped particle inlet and chemically analyzed by PERCI-MS. PERCI is a soft ionization method that permits the direct measurement of relatively high molecular weight compounds, facilitating molecular identification. In addition to cyclic oxygenates, such as secondary ozonides and geminal diperoxides that were reported previously, we demonstrate the formation of polymers at the particle sur...
2006-01-01
Energy Technology Data Exchange (ETDEWEB)
The proton and deuteron spectra following resonant multiphoton ionization of H{sub 2} and HD at 193 nm through the {ital E},{ital F} state have been studied at power densities of 10{sup 10} W/cm{sup 2}. Our results show that the intermediate state induces competition between 3(2+1)-photon ionization, dissociation, and dissociative ionization channels. We find that the competition depends on the specific vibrational and rotational levels excited in the intermediate state. At the same time, the mere presence of this bound intermediate state renders these three-photon fragmentation channels so efficient that higher-order fragmentation processes, such as Coulomb explosions requiring many more photons, are not observed.
1991-04-01
Active hydrogen by chemical ionization mass spectrometry.
A means of determination of a ctive hydrogen of hydroxyl, carboxyl, sulfhydryl, amino, amido and sulfonamido groups by chemical ionization mass spectrometry using ammonia and trideuterioammonia as reagent gases is described. The method is based on exchange of active hydrogen for deuterium occurring during the chemical ionization process using trideuterioammonia, with comparison of m/z for ammonium adduct [M + NH1]+ and trideuterioammonium adduct [M--nH + nD + ND4]+, or of protonated molecular ion [M + H]+ and deuteronated molecular ion [M--nH + nD + D]+ yielding the number of active hydrogens. Applications have been made to several classes of biologically important compounds. PMID:427257
1979-01-01
Energy Technology Data Exchange (ETDEWEB)
Minimally invasive treatment for small renal cell carcinoma (RCC) can be necessary in selected patients and, anyway, is desirable. In situ ablation techniques, including RFA, have been developed. The aim of this study is to evaluate the feasibility, safety and short-term local effectiveness of percutaneous US-guided RFA in a small series, as well as mid-term patient outcome. Thirteen patients with a total of 18 tumors (17 small lesions, 35 mm in size or less, and a larger one, 75 mm in size) underwent 19 RFA sessions. Seven patients had a solitary kidney, and three suffered from VHL disease, too. We treated four lesions in a patient with a bilateral tumor. In another patient, three lesions were ablated. Seventeen tumors were RCC; one was a metastasis from lung cancer. Eight lesions were parenchymal, six exophytic, two parenchymal/exophytic, one parenchymal/central and one central. A monopolar RF system with multitined expandable electrode ...
2004-12-01
{alpha}- and {beta}-Cyclodextrin [2]rotaxanes with (diethylenetriamine)platinum(II) stoppers
Energy Technology Data Exchange (ETDEWEB)
A series of dinuclear platinum(II) complexes, [(dien)Pt(NH{sub 2}(CH{sub 2}){sub n}NH{sub 2})Pt(dien)]Cl{sub 4} (dien = diethylenetriamine, n = 8, 9, 10, and 12) and their corresponding [2]rotaxanes with {alpha}-cyclodextrin ({alpha}-CD), [(dien)Pt{l_brace}NH{sub 2}(CH{sub 2}){sub n}NH{sub 2}{center_dot}{alpha}-CD{r_brace}Pt(dien)]Cl{sub 4}, have been synthesized and characterized by {sup 1}H, {sup 13}C, and {sup 195}Pt NMR spectroscopy and electrospray mass spectrometry. The rotaxanes were prepared by reacting the {l_brace}NH{sub 2}(CH{sub 2}){sub n}NH{sub 2}{center_dot}{alpha}-CD{r_brace} pseudorotaxanes with [Pt(dien)]Cl, to stopper the included linear {alpha},{omega}-diaminoalkane chains with the inert Pt(II) end groups. The kinetics of the self-assembly and dissociation of the {beta}-CD rotaxane, [(dien)Pt{l_brace}NH{sub 2}(CH{sub 2}){sub 10}NH{sub 2}{center_dot}{beta}-CD{r_brace}Pt(dien)]{sup 4+}, were investigated by using {sup 1}H NMR and are indicative of ...
2005-12-15
British Library Electronic Table of Contents (United Kingdom)
OBJECTIVE To present our initial experience of thulium laser resection via a flexible cystoscope for recurrent non-muscle-invasive bladder cancer (ThuRBT), as transurethral resection for bladder tumour (TURBT) is regarded as the reference standard for treating this disease, but alternative laser resection or ablation is suitable especially for recurrent tumours. PATIENTS AND METHODS From January 2005 to October 2005, 32 patients with early recurrent bladder tumour (recurrent within a year after TURBT) were treated with ThuRBT via a flexible cystoscope. The follow-up included urine analysis, ultrasonography and cystoscopy every 3 months. RESULTS All patients were treated successfully with ThuRBT in one session, with no bladder haemorrhage, obturator nerve reflex or vesicle perforation. Rand...
2008-01-01
Energy Technology Data Exchange (ETDEWEB)
The feasibility of spectroscopic measurement of the velocity distribution of alpha particle using the ablation cloud of a lithium or boron pellet was tested in the DT experiment of TFTR. The measurement was performed using a 10-channel narrow-band filtered spectrometer in the wavelength covering the 3.5 MeV alpha particle Doppler broadening region of the He II 468.6 nm line and its vicinity. The spectra from a lithium pellet consists of the continuum bremsstrahlung background, lithium line emissions and possibly a 468.6 nm helium line. However, no clear evidence of alpha particles was observed, even when boron pellets were injected. (orig.) 4 refs.
1997-03-01
Pulsed laser deposition of titanium-carbonitride thin films
Energy Technology Data Exchange (ETDEWEB)
The goal of this research program is to determine whether pulsed laser deposition is an effective alternative method for growing TiCN thin films. Pulsed laser deposition (PLD) is chosen because of its well-documented capability for growing uniform, stoichiometric films in ultra-high vacuum or gaseous environments. Processing of thin films by PLD is also achieved at relatively low temperatures compared with CVD processing. Given these attributes, the primary objectives in this article are to determine whether nitrogen may be readily incorporated into films resulting from the laser-ablation of TiC in an N{sub 2} environment, determine what effect nitrogen has on mechanical properties, and determine whether nitrogen incorporation is strongly influenced by processes unrelated to laser deposition (e.g., thermally-activated surface reactions).
1997-05-15
Modeling of ablation by photospallation using the computer program PUFF/DFRACT
Energy Technology Data Exchange (ETDEWEB)
In general, macroscopic material failure is a manifestation of irreversible changes at the microscopic level. Many tissues, which may appear to be macroscopically homogeneous, are, at a fundamental microscopic level, a composite material. For example, cornea is composed of a hyaluronic acid matrix in which layers of collagen fibers are overlaid in a crossing pattern. The points where the collagen fibers intersect are potential nucleation sites for microscopic defects, which under the action of tensile stress, nucleate, grow and coalesce to form macroscopic failure planes, or spall planes. Using a model based on microstructural evolution, this paper examines the failure process during photoablation. Specifically, the paper describes a physically motivated, micromechanical model based on the nucleation and growth of spherical voids. This model is then used to simulate photoablation of cornea. Potential for using this model to predict the stress wave and material damage measured by ...
1995-03-01
Localization of small magnets against a noisy background
Effective localization of small magnets against a noisy, real world background can involve various methods to first identify the magnetic fields produced by the magnet of interest, then to filter out background noise, and then to analyze the available magnetic field data to localize the magnet. Here we discuss low cost techniques which allow localization of small magnets with field strengths in the milliGauss range against real world background fields in the range of hundreds of mG, which may be fluctuating by up to tens of mG. Such techniques allow magnet tracking to be used to localize catheters in place of more invasive and expensive methods, e.g. fluoroscopy, for a variety of applications, including drug infusion with peripherally inserted central catheters (PICCs), laser ablation (TMR, PTMR) and introduction of pacemaker leads.
2001-05-01
Image-guided percutaneous cryotherapy for the management of gynecologic cancer metastases
British Library Electronic Table of Contents (United Kingdom)
Objective To report the clinical response to image-guided percutaneous cryotherapy (IPC) for the palliative management of localized metastases in patients with gynecologic malignancies. Methods Institutional review board approval and patient consent were obtained. Gynecologic oncology patients were identified from our institution's cryotherapy database from August 2003 to August 2007. Cryotherapy was performed with 2.4?mm diameter probes (Endocare, Irvine, CA) with ultrasound or computerized tomography (CT) guidance under conscious sedation and local anesthesia. Follow-up was conducted by imaging studies and clinical encounters, using Response Evaluation Criteria in Solid Tumors (RECIST criteria). Results Twenty-eight ablation sessions were performed for 41 metastatic foci in 15 patients w...
2008-01-01
Free-electron-laser-induced shock-wave control and mechanistic analysis using pulse control
International Nuclear Information System (INIS)
The wavelength of the free electron laser (FEL) in Osaka University can be continuously varied in the range of 5.0-20.0 #mu#m. The FEL has a double-pulse structure, consisting of a train of macropulses of pulse duration 12 #mu#s. Each macropulse contains a train of 330 micropulses of pulse duration 5 ps. The tunability and picosecond pulses afford new medical and biological applications. However, a macropulse of long pulse duration leads to undesirable secondary effects. Precise control of the macropulse duration is essential for the high-precision applications of the FEL. An FEL pulse control system using acousto-optic modulators has been developed to investigate mechanical (shock-wave) effects of the FEL on living tissues. With this system, we have controlled photoinduced shock waves and determine the mechanism of interaction during FEL-induced tissue ablation.
2008-11-01
British Library Electronic Table of Contents (United Kingdom)
Background: Ventricular repolarization (VR) is strongly influenced by heart rate (HR) and autonomic nervous activity, both of which also are important for arrhythmogenesis. Their relative influence on VR is difficult to separate, but might be crucial for understanding while some but not other individuals are at risk for life-threatening arrhythmias at a certain HR. This study was therefore designed to assess the -pure- effect of HR increase by atrial pacing on the ventricular gradient (VG) and other vectorcardiographically (VCG) derived VR parameters during an otherwise unchanged condition. Methods: In 19 patients with structurally normal hearts, a protocol with stepwise increased atrial pacing was performed after successful arrhythmia ablation. Conduction intervals were measured on averag...
2011-01-01
International Nuclear Information System (INIS)
The paper describes novel analytical methods developed for the detection of previous neutron irradiation and reprocessing of illicit nuclear materials, which is an important characteristic of nuclear materials of unknown origin in nuclear forensics. Alpha spectrometry and inductively coupled plasma sector-field mass spectrometry (ICP-SFMS) using solution nebulization and direct, quasi-non-destructive laser ablation as sample introduction were applied for the measurement of trace-level "2"3"2U, "2"3"6U and plutonium isotopes deriving from previous neutron irradiation of uranium-containing nuclear materials. The measured radionuclides and isotope ratios give important information on the raw material used for fuel production and enable confirm the supposed provenance of illicit nuclear material.
2009-04-01
British Library Electronic Table of Contents (United Kingdom)
TP63, a member of the TP53 gene family, is a nuclear marker of myoepithelial cells. Antibody against p63 is frequently used to aid in the diagnosis of prostate carcinoma, as well as in the identification of myoepithelial cells in other tissues including the breast. p63 is also a marker for squamous cell carcinoma. Recently, it was found that all p53 family members are involved in regulating the process of muscle differentiation through the retinoblastoma (RB) protein. Ablation of these p53 family functions blocks the differentiation program and promotes malignant transformation by enabling cooperating oncogenes to transform myoblasts. We therefore studied p63 expression in a number of neoplasms with myogenic differentiation. Immunohistochemical staining for p63 was performed on paraffin se...
2011-01-01
Analysis by mass spectroscope device provided with ion source of induced plasma
International Nuclear Information System (INIS)
This chapter consists of some points including an introduction, the basic parts of mass spectroscope device, sample introduction into the inductively coupled plasma, pneumatic nebuliser, ultrasonic nebuliser, dry gas cloud system, laser ablation unit, inductively coupled plasma-ion source, extraction of ions from ion source, mass analysis, quad-polar mass spectrometer, dual assembly mass spectrometer, mass spectrometer by calculation of time of flight, ion interferences and the ability of resolution, ion counter, working conditions of inductively coupled plasma mass spectroscope device, efficiency of ion transportation in an inductively coupled plasma mass spectroscope device and applications of analysis using mass spectroscope of induced plasma including nuclear, industrial, geological, environmental and archaeological applications, measurement of isotopes ratio and applications in tracing crimes.
Energy Technology Data Exchange (ETDEWEB)
Various characteristics of F stars are described. The spectra of F stars are analyzed, and it is determined that the spectral types are based on ionization levels. The CNO cycle and rotation speeds of the stars are examined. The period-luminosity relation of pulsators is studied, and specific examples of unstable pulsators are presented.
1987-02-01
Targeted nanoparticles that deliver a sustained, specific release of paclitaxel to irradiated tumors
UK PubMed Central (United Kingdom)
To capitalize on the response of tumor cells to ionizing radiation, we developed a controlled-release nanoparticle drug delivery system using a targeting peptide that recognizes a radiation-induced...Full Text Available
2010-06-01
Spectrophotometry of H II regions in the spiral galaxy M101
Energy Technology Data Exchange (ETDEWEB)
Spectral line intensity data are presented for ionized hydrogen regions in the giant spiral galaxy M101. The influence of interstellar extinction is assessed and electron temperatures of the gas clouds are derived.
1981-04-01
Numerical simulations predict that a large number of baryons reside in intergalactic space at temperatures between 10^5-10^7 K. Highly-ionized metals, such as O VII and O VIII, are good tracers of this ``warm-hot intergalactic medium'', or WHIM. For collisionally-ionized gas, the ionization fraction of each ion peaks at some particular temperature (``peak temperatures''), so different ions can therefore trace the IGM at different temperatures. We performed a hydrodynamic simulation to study the metal distributions in the IGM. We then draw random lines-of-sight across the simulated region and synthesize resonance absorption line spectra in a similar way to simulating the Ly-alpha forest. By studying the distribution functions of H- and He-like O, Si and Fe in a collisionally-ionized IGM and comparing with semi-analytic results based on the Press-Schechter formalism, we find: (1) ions with higher peak ...
2001-01-01
UK PubMed Central (United Kingdom)
AbstractBackgroundIonizing radiation (IR) initiates intracellular oxidative stress through enhanced formation of reactive oxygen species (ROS) that attack DNA leading...Full Text Available
2010-05-01
Motion management with phase-adapted 4D-optimization
UK PubMed Central (United Kingdom)
Cancer treatment with ionizing radiation is often compromised by organ motion, in particular for lung cases. Motion uncertainties can significantly degrade an otherwise optimized treatment plan....Full Text Available
2010-09-07
UK PubMed Central (United Kingdom)
Our goal was to determine whether chlorpyrifos oxon, dichlorvos, diisopropylfluorophosphate (DFP), and sarin covalently bind to human albumin. Human albumin or plasma was treated with organophosphorus...Full Text Available
2007-02-15
MAGIC - Multi Anode Gas Ionization Chamber
Energy Technology Data Exchange (ETDEWEB)
A novel approach to the Bragg curve spectroscopy is utilized to construct a charged particle detector which makes fragment elemental identification and energy measurement possible. The advantage of the construction includes good timing and spectroscopic properties with a very low energy threshold. ((orig.))
1994-12-01
K-shell ionization of Al, V, Fe, Cu, Y, Mo, Ag, and Sn by 1-5-MeV alpha-particle bombardment
International Nuclear Information System (INIS)
(Jan 1974). United States McKnight, RH Thornton, ST Karlowicz, RR
Identification of novel DNA repair proteins via primary sequence, secondary structure, and homology
UK PubMed Central (United Kingdom)
BackgroundDNA repair is the general term for the collection of critical mechanisms which repair many forms of DNA damage such as methylation or ionizing radiation. DNA repair has...Full Text Available
Evidence for a lack of DNA double-strand break repair in human cells exposed to very low x-ray doses
UK PubMed Central (United Kingdom)
DNA double-strand breaks (DSBs) are generally accepted to be the most biologically significant lesion by which ionizing radiation causes cancer and hereditary disease. However, no information on the...Full Text Available
2003-04-29
DNA sequencing using biotinylated dideoxynucleotides and mass spectrometry
UK PubMed Central (United Kingdom)
Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MS) has been explored widely for DNA sequencing. The major requirement for this method is that the DNA sequencing fragments...Full Text Available
2001-11-01
UK PubMed Central (United Kingdom)
A compensatory response, viz. in vivo recovery from radiation damage to mitochondria, occurs in preclimacteric pear fruits (Pyrus communis L.) treated with ionizing...Full Text Available
1968-07-01
Bragg curves of fission fragments in gases
Energy Technology Data Exchange (ETDEWEB)
An unexpectedly high probability of collisions between the fission particles and the atoms in an ionization chamber along the entire particle track causes a strong fluctuation of the shapes of the Bragg curves. This fluctuation imposes an upper limit of the charge resolution ..delta..Z/Z which can be achieved.
1986-03-01
Biological Research for Radiation Protection
International Nuclear Information System (INIS)
The work scope of 'Biological Research for the Radiation Protection' had contained the research about ornithine decarboxylase and its controlling proteins, thioredoxin, peroxiredoxin, S-adenosymethionine decarboxylase, and glutamate decarboxylase 67KD effect on the cell death triggered ionizing radiation and H_2O_2(toxic agents). In this study, to elucidate the role of these proteins in the ionizing radiation (or H_2O_2)-induced apoptotic cell death, we utilized sensesed (or antisensed) cells, which overexpress (or down-regulate) RNAs associated with these proteins biosynthesis, and investigated the effects of these genes on the cytotoxicity caused by ionizing radiation and H_2O_2(or paraquat). We also investigated whether genisteine(or thiamine) may enhance the cytotoxic efficacy of tumor cells caused by ionizing radiation (may enhance the preventing effect radiation or paraquat-induced damage) because ...
Advanced MRI Methods for Assessment of Chronic Liver Disease
UK PubMed Central (United Kingdom)
MRI plays an increasingly important role for assessment of patients with chronic liver disease. MRI has numerous advantages, including lack of ionizing radiation and the possibility of performing...Full Text Available
2009-07-01
The medical exposures to ionizing radiations, it is a world priority in radiation protection
International Nuclear Information System (INIS)
The document published under A/63:46 and titled report of the scientific committee of United Nations for the study of ionizing radiations effects, gives the situation of the fifty sixth session of the committee that stood at Vienna from the 10. to 18. july 2008. In the chapter 3 of this report the writers summarize the strategic planning and the working program of the scientific committee for the period 2009-2013. They note that the committee worry about the inadequate means, particularly in personnel. The priorities for the given period will be the medical exposure of patients, the radiation levels and the effects of energy production, the exposure to natural radiation sources and the improvement of the understanding of the effects of the low doses radiation exposure. (N.C.)
Study of total ionizing dose radiation effects on nitride/oxide stack gate MOS capacitor
International Nuclear Information System (INIS)
The aim of this paper is to investigate the total ionizing dose (TID) radiation effects on MOS capacitor with nitride/oxide stack gate. The stack gate MOS capacitors are fabricated with 20 nm oxide, 40 nm nitride or 110 nm nitride respectively. Through the analysis of CV curve of the irradiation capacitors, it is found that the degradation of the CV curve is due to a significant increase of interface traps and somewhat smaller oxide charge. It is also shown that the thicker of the nitride, more interface traps and oxide charge will be occurred. (authors)
2008-07-01
Radiation-induced chemical modification of wood
International Nuclear Information System (INIS)
The results of theoretical and experimental investigations, describing the effect of ionizing radiation on wood and its main components and methods for production of wood-plastic composites by means of radiation-induced chemical modification are generalized. Domestic and foreign experience in their production is systematized; physico-mechanical characteristics of new material, simulation and calculation of irradiating devices, as well as calculation and experimental study of #gamma#-radiation attenuation both by wood material and by wood of different species are given. Gamma sources ("6"0Co isotope, a hot loop of a nuclear reactor) as well as electron accelerators are considered as ionizing radiation sources.
1985-01-01
New techniques for electron-ion collision studies
International Nuclear Information System (INIS)
We have constructed an apparatus to study electron impact ionization of ions which should provide additional insight into the mechanisms involved. Using multiparameter coincidence techniques, we will detect both outgoing electrons from ionization process and will be able to analyze the momenta of both particles simultaneously. Coupled with a high resolution electron gun, this information should have broad application to the difficult problem of three bodies interacting via the long range Coulomb force. If sufficient accuracy can be achieved, information regarding the relative phase of the outgoing electron wavefunctions can be obtained.
Magnetic braking in weakly ionized media
International Nuclear Information System (INIS)
The combined magnetic braking-ambipolar diffusion problem in weakly ionized, rigidly rotating disks is studied. An analytical solution is presented for a disk whose angular velocity and magnetic yield vectors are aligned with the symmetry axis, illustrating the effects of the relative azimuthal drift of neutrals and ions. The effects of radial drift are added, commenting on the ratio of the characteristic ambipolar diffusion and magnetic braking time scales in high-mass and low-mass disks. A numerical calculation is used to show the combined action of these two processes. 31 references.
Ionizing radiation hardening procedure of CCD's
International Nuclear Information System (INIS)
The procedure of charge-coupled devices (CCD) are investigated by using MOS capacitors for enhancing their ionizing radiation tolerance. Authors have found that the gate oxidation temperature, thickness of SiO_2 gate insulator and high temperature processes after gate oxidation are crucial for determining the radiation tolerance of the devices, and proposed to decrease the thickness of gate insulator, perform gate oxidation at 1000 deg C by means of dry oxidation and minimize the number of high temperature procedure steps after gate oxidation. All stated above is a necessary preparation for priducing radiation hardened charge-coupled devices.
Health effects[1997 Scientific Report of the Belgian Nuclear Research Centre
Energy Technology Data Exchange (ETDEWEB)
The objectives of the research in the field of epidemiology , performed at the Belgian Nuclear Research Centre SCK-CEN are (1) to study cancer mortality and morbidity in nuclear workers in Belgium; (2) to document the feasibility of retrospective cohort studies in Belgium; (3) to participate in the IARC study. For radiobiology, the main objectives are: (1) to elucidate the mechanisms of the effects of ionizing radiation on the mammalian embryo during the early phase of its development, (2) to assess the genetic risks of maternal exposure to ionizing radiation, (3) to elucidate the mechanisms by which damage to the brain and mental retardation are caused in man after prenatal irradiation. The main achievements in these domains for 1997 are presented.
1998-07-01
International Nuclear Information System (INIS)
Hitherto in this laboratory, ionization coefficients alpha and attachment coefficients #eta# have been determined from Townsend's discharge experiments by a curve-fitting method. However, the method proved to be laborious, Formulae have been derived in this paper to give value of alpha and #eta# as a function of Isubo, Isub1 and Isub2 where Isubo is the photoelectric current at a gap setting d and Isub2 the current at another gap setting 2 d. The values of alpha and #eta# obtained give currents in agreement to within 3% in the best cases with the observed currents.
Energy Technology Data Exchange (ETDEWEB)
Neutral atom beams with energies above 200 keV may be required for various purposes in magnetic fusion devices following TFTR, JET and MFTF-B. These beams can be produced much more efficiently by electron detachment from negative ion beams than by electron capture by positive ions. We have investigated the efficiency with which such neutral atoms can be produced by electron detachment in partially ionized hydrogen plasma neutralizers.
1980-09-01
Effects of relativity and wave functions on atomic L- and M-shell ionization by protons
Energy Technology Data Exchange (ETDEWEB)
Atomic L- and M-shell ionization cross sections by protons have been calculated in the plane-wave Born approximation for /sub 79/Au and /sub 92/U with incident energy from 0.1 to 3 MeV with use of relativistic and nonrelativistic Hartree-Slater wave functions. These results are compared with those from the screened hydrogenic model to study the effects of relativity and wave functions. The relativistic and wave-function effects are found to operate in opposite directions. For M/sub 1,2,3/-subshell cross sections, severe cancellations occur between these two factors.
1984-10-01
Discharging-ionization of tellurium in nitric acid electrolytes in the presence of tartrate ions
The authors investigated the influence of tartaric acid, which possesses complex-forming properties. In order to establish the optimum system of possible refinement of tellurium, the authors study the kinetics of both the cathodic and the anodic processes. The investigation of processes of discharging-ionization of tellurium from nitric acid electrolytes in the presence of tartrate ions showed the possibility of preparing a nitric-tartaric acid electrolyte which can be used for commercial purposes and from which a high-purity raffinate was obtained from technical tellurium.
1986-03-20
The high-sensitive magnetic levitated electrode ionization chamber of the noncontacting type
Energy Technology Data Exchange (ETDEWEB)
There are two types of ionization chamber using magnetically levitated electrode: one is that by Tanaka et al. and the other, by authors'. The latter lacks the sensitivity relative to the former and thereby to solve the problem, authors made an improvement so that the electrode charge could be readout by noncontact after the leviated electrode was electrified by noncontact for an interval. This new type ionization chamber made it possible to measure the quite low dose radiation with stability and high sensitivity. Actually, the electrode was suspended by the teflon thread fixed on the steel cup levitated magnetically in the ionization chamber of which wall was covered by Al and equipped with an electrostatic charger for the electrode by noncontact. After measurement, the electrode was moved in the Faraday cage placed under the chamber to readout the voltage. For operation conditions of the apparatus, observation ...
1999-09-01
Energy Technology Data Exchange (ETDEWEB)
This work presents a study of the {sup 1}P{sup 0} excited states of He that can be reached by absorption of a single photon carrying an energy close to the double ionization threshold (DIT) (79 eV). Above the DIT, these states are the double continuum states; below, they are the double excited states. These two types of states are tightly coupled to the single continuum states with or without excitation of the residual ion He{sup +}, owing to their degeneracy in energy. In a one-photon process, these states can only be formed owing to the electronic correlations in the system which must be well described to obtain quantitative good results. Our study is a part of the work which aims at a united description of all these doubly excited, ionized-excited, and double continuum states. We use the Hyperspherical R-Matrix with Semiclassical Outgoing Waves (HRM-SOW) method, initially dedicated to double photoionization studies. We extend it to extract ...
2007-04-15
On the Utility of Antiprotons as Drivers for Inertial Confinement Fusion
Energy Technology Data Exchange (ETDEWEB)
By contrast to the large mass, complexity and recirculating power of conventional drivers for inertial confinement fusion (ICF), antiproton annihilation offers a specific energy of 90MJ/{micro}g and thus a unique form of energy packaging and delivery. In principle, antiproton drivers could provide a profound reduction in system mass for advanced space propulsion by ICF. We examine the physics underlying the use of antiprotons ({bar p}) to drive various classes of high-yield ICF targets by the methods of volumetric ignition, hotspot ignition and fast ignition. The useable fraction of annihilation deposition energy is determined for both {bar p}-driven ablative compression and {bar p}-driven fast ignition, in association with 0-D and 1-D target burn models. Thereby, we deduce scaling laws for the number of injected antiprotons required per capsule, together with timing and focal spot requirements. The kinetic energy of the injected antiproton beam required to ...
2003-10-20
Lung dose calculations at kilovoltage x-ray energies using a model-based treatment planning system
International Nuclear Information System (INIS)
The determination of the dose to organs from diagnostic x rays has become important because of reports of radiation injury to patients from fluoroscopically guided interventional procedures. We have modified a convolution/superposition-based treatment planning system to compute the dose distribution for kilovoltage beams. We computed lung doses using this system and compared them to those calculated using the CDI3 organ dose calculation program. We also computed average lung doses from a simulated radiofrequency ablation procedure and compared our results to published doses for a similar procedure. Doses calculated using this system were an average of 20% lower for AP beams and 7% higher for PA beams than those obtained using CDI3. The ratio of the average dose to the lungs to the skin dose from the simulated ablation procedure ranged from 25% higher to 15% lower than that determined by other authors. Our results show that a treatment planning ...
2001-02-01
Study on the energy distribution of ion beams extracted from the sputter-type negative-ion source
International Nuclear Information System (INIS)
The energy distribution of ion beams is important especially for low energy ion beam applications. The energy distributions of negative-ion beams produced through secondary ion emission by sputtering were measured and compared with theoretically estimated distributions by use of four different negative-ion production probability equations (modified surface ionization model, exponential velocity dependence model, and our modified exponential velocity dependence models (modified decaying factor model and combination model of velocity dependence and surface ionization)). In the measurements, the energy distributions of C"- and Ag"- beams had a peak at a few to several eV and the full width at half maximum were 15 eV and 11 eV, respectively. These results could be well explained by the estimated distributions by virtue of our combination model or the modified surface ionization model. copyright 1996 American Institute of ...
1995-10-23
Somatic and genetic effects of small doses of ionizing radiations in man
International Nuclear Information System (INIS)
Estimations on the somatic and genetic effects of small doses of ionizing radiations in Man have been proposed by the Advisory Committee on the Biological Effects of Ionizing Radiation, set up by the U.S. National Academy of Sciences. They have been published in an important report, issued in 1972, from which we briefly analyze here the Chapter dealing with the somatic effects. Small doses of raditions are expected to promote only carcinogenic effects. After a rapid survey of the human experience on which the estimations are based, as regards the latent period of cancers, the plateau region (period of high risk) and the absolute and relative risk expressed per rem, per 10"6 persons, per year, for leukaemia (having the highest risk) and for the ''other cancers''. These estimations were obtained by linear extrapolation to the 1 rem level from observations made after irradiation at relatively high dose levels and much higher dose-rates. This ...
1976-01-01
Salmonella radicidation of poultry carcasses
International Nuclear Information System (INIS)
This thesis reports investigations using gamma-radiation to decontaminate poultry carcasses. The application to foods of doses of ionizing radiation sufficient to reduce the number of viable specific non-sporeforming pathogenic microorganisms so that none is detectable in the treated food by any standard method is termed radicidation. The doses used in this study were at such a level that no undesirable or unfavourable side-effects occurred. The effects of these doses were studied on salmonellae and other microorganisms present in, or associated with poultry carcasses and in liquid and on solid culture media as well. Decimal reduction (D_1_0) values were estimated. These represent the dose (kGy) required to achieve a reduction in initial colony count from N_0 to 0.1 N_0. Together with the estimation of the numbers of Salmonella present per carcass the data were used to predict the effect of an ionizing radiation treatment of poultry. Data on ...
2005-09-22
Risks and safety aspects related to PET/MR examinations
International Nuclear Information System (INIS)
The introduction of positron emission tomography (PET)/magnetic resonance (MR) systems into medical practice in the foreseeable future may not only lead to a gain in clinical diagnosis compared to PET/computed tomography (CT) imaging due to the superior soft-tissue contrast of the MR technology but can also substantially reduce exposure of patients to ionizing radiation. On the other hand, there are also risks and health effects associated with the use of diagnostic MR devices that have to be considered carefully. This review article summarizes biophysical and biological aspects, which are of relevance for the assessment of health effects related to the exposure of patients to both ionizing radiation in PET and magnetic and electromagnetic fields in MR. On this basis, some considerations concerning the justification and optimization of PET/MR examinations are presented - as far as this is possible at this very early stage. Current safety ...
2009-03-01
Resonance ionization spectroscopy at {sup 240f,242f}Am fission isomers
Energy Technology Data Exchange (ETDEWEB)
Optical Isotope shift measurements have been performed for the {sup 240f,242f}Am fission isomers to test the stability of nuclear deformation as function of the neutron number. The method is based on resonance ionization spectroscopy (RIS) in a buffer gas cell with fission detection of the ionization process. The {sup 240f,242f}Am fission isomers have been produced by {sup 242}Pu(p, 3n), {sup 242}Pu(d, 2n) reactions, respectively. Relative isotope shift ratios X{sub exp}{sup 242f}(500 nm)=IS{sup 242f,241}/IS{sup 243,241}=41.4(8) and X{sub exp}{sup 240f}(500 nm)=IS{sup 240f,241}/IS{sup 243,241}=39.2(8) were measured. From these ratios a small difference {delta}{beta}{sub 2}{sup 242f,240f}=0.0076(14) of the deformation parameter {beta}{sub 2} can be deduced assuming that the isotope shift between the reference isotopes {sup 241,243}Am is caused by a pure volume change. (orig.)
1997-10-01
Position sensitive and Bragg curve spectroscopy detector system for heavy ion reaction studies
International Nuclear Information System (INIS)
A complete heavy ion identification system in heavy ion reaction studies consists, in general, of: 1) a position sensitive avalanche counter, and 2) ionization chamber to obtain total energy as well as a heavy ion identifier signal (such as the E#DELTA#E signal from a E-#DELTA#E type detector or the height of the Bragg peak that scales as Z of the heavy ion in a Bragg curve ionization chamber). In addition, a time-of-flight information may be needed to resolve the masses of the ions. With this motivation in mind, a composite detector system consisting of a Bragg curve spectroscopy ionization chamber (BCS-IC) and a one dimensional position sensitive parallel grid avalanche counter (XPS-PGAC) has been developed and used successfully at the BARC-TIFR pelletron accelerator facility. The design and performance of this gas detector system are reported. (author). 4 refs., 2 figs.
Oxygen O18 method and the search for the ionization mechanism in sputtering of oxygenated surfaces
International Nuclear Information System (INIS)
Recently developed oxygen O18 method [K. Franzreb, J. Lorincik, P. Williams, Surf. Sci. 573 (2004) 291; R.C. Sobers, K. Franzreb, P. Williams, Appl. Surf. Sci. 231-232 (2004) 729; P. Williams, R.C. Sobers Jr., K. Franzreb, J. Lorincik, Appl. Surf. Sci. 252 (2006) 6429] is able to quantitatively determine the flux ratio of oxygen to matrix species at dynamical SIMS sputtering. This flux ratio can be directly related to the surface oxygen concentration at dynamical sputtering - an important parameter controlling the ionization yield of emitted species. It is argued that the oxygen O18 method is a worthy step forward in gathering relevant experimental data that might eventually lead to the understanding of oxygen enhancement mechanism in SIMS. A current status of understanding of the ionization processes in SIMS is briefly discussed in terms of non-adiabatic strongly velocity dependent processes represented by the electron tunneling and ...
2008-12-15
A new method, near-infrared laser desorption/ionization aerosol mass spectrometry (NIR-LDI-AMS), is described for the real time analysis of organic aerosols at atmospherically relevant mass loadings. Use of a single NIR laser pulse to vaporize and ionize particle components deposited on an aluminum probe results in minimal fragmentation to produce exclusively intact pseudomolecular anions at [M-H](-). Limits of detection (total particulate mass sampled) for oxidized compounds of relevance to atmospheric primary and secondary organic aerosol range from 89 fg for pinic acid to 8.8 pg for cholesterol. NIR-LDI-AMS was used in conjunction with the University of Vermont Environmental Chamber to study secondary organic aerosol (SOA) formation from ozonolysis of limonene at total aerosol mass loadings ranging from 3.2 to 25.0 ?g m(-3) and with a time resolution of several minutes. NIR-LDI-AMS permitted direct delineation between gas-phase, homogeneous ...
2010-10-01
Matrix-assisted laser desorption fourier transform mass spectrometry for biological compounds
The recent development of matrix-assisted UV laser desorption (LD) mass spectrometry has made possible the ionization and detection of extremely large molecules (with molecular weights exceeding 100,000 Daltons). This technique has generated enormous interest in the biological community for the direct examination of large peptides and oligonucleotides. Although this matrix-assisted ionization method has been developed and used almost exclusively with time-of-flight (TOF) mass spectrometers, research is currently in progress to demonstrate this technique with trapped ion mass spectrometers, such as Fourier transform ion cyclotron resonance mass spectrometry (FTMS). The potential capabilities of FTMS for wide mass range, high resolution measurement, and ion trapping experiments suggest that this instrumental technique should be useful for the detailed structural characterization of large ions generated by the matrix-assisted technique. We have ...
1990-01-01
Locally Optimally-emitting Clouds and the Narrow Emission Lines in Seyfert Galaxies
The narrow emission line spectra of active galactic nuclei are not accurately described by simple photoionization models of single clouds. Recent Hubble Space Telescope images of Seyfert 2 galaxies show that these objects are rich with ionization cones, knots, filaments, and strands of ionized gas. Here we extend to the narrow line region the ``locally optimally emitting cloud'' (LOC) model, in which the observed spectra are predominantly determined by powerful selection effects. We present a large grid of photoionization models covering a wide range of physical conditions and show the optimal conditions for producing many of the strongest emission lines. We show that the integrated narrow line spectrum can be predicted by an integration of an ensemble of clouds, and we present these results in the form of diagnostic line ratio diagrams making comparisons with observations. We also predict key diagnostic line ratios as a function of distance ...
1997-01-01
K beta X-ray transition energies of M-shell-ionized ions of Ti through Ni in a plasma
Energy Technology Data Exchange (ETDEWEB)
K beta X-ray lines from partially M-shell-ionized ions of titanium through nickel which are produced in vacuum-spark plasmas have been observed systematically for the first time, using a high-resolution curved-crystal spectrometer. Each K beta line is clearly separated into its corresponding charge state. As a result, it is possible to measure the K beta-type transition energies of the M-shell-ionized ions. The transition energies accurately determined are compared with those calculated for iron ions, and the agreement is excellent except for ions having some additional 3d outer-shell electrons or 3s inner-shell vacancies. The square root of the K beta transition frequency is expressed as a linear function of the nuclear charge for isoelectronic sequences. The effective nuclear charges have been also determined for each K beta transition. The 3p electrons do not affect the effective nuclear charges. 10 references.
1985-05-01
Ion-induced M X-ray emission from heavy lanthanides
Energy Technology Data Exchange (ETDEWEB)
Thick targets of several heavy lanthanide (Ho-Lu) compounds were bombarded by protons and /sup 3/He ions of 3 MeV/amu, and M/sub ..cap alpha../ and M/sub ..beta../ X-rays were measured with a crystal spectrometer. Ionization probabilities of the N-shell for zero impact parameter were obtained from the X-ray intensity ratio for proton and /sup 3/He ion impacts. A shell dependence of the ionization probability was found in a scaling plot. X-ray spectra of lanthanide compounds were compared and no chemical effect was observed. This result is considered to be due to the fact that the main component of M/sub ..cap alpha../ and M/sub ..beta../ lines is for radiative transition after the refilling of the 4f orbit (3d/sup -1/4f/sup n+1/ -> 4f/sup n/) where n denotes the number of 4f electrons of the target atom before ionization.
1987-12-01
How to overestimate risks of ionizing radiations
International Nuclear Information System (INIS)
Ignoring the numerous, known and mainly unknown, interactions between chemicals and ionizing radiations, causes strong controversy about the risks of ionizing radiations. Yet the best known interactions between chemicals and radiations is that between radon and tobacco smoke. Although it is and it will be always impossible to derive quite quantitative laws for this interaction, it has been possible to derive some semi-quantitative relationships based on reasonable assumptions and statistics on lung cancer deaths in developed countries. They show that ignoring the dangers of tobacco smoking as we did still long after we had recognised the dangers of radiations, could asses to radiations thirty or forty times more risks than reality. As present world is flown by tens of thousands chemicals, little or not present in a natural environment, and as it would be very surprising that some hundreds of these do not behave like those contained in tobacco ...
High Angular Resolution Imaging Spectroscopy of the Galactic Ultra-Compact HII Region K3-50A
Gemini North adaptive optics imaging spectroscopy is presented for the Galactic ultra-compact HII (UCHII) region K3-50A. Data were obtained in the K-band using the Near-infrared Integral Field Spectrograph (NIFS) behind the facility adaptive optics module ALTAIR in natural guide star mode. The NIFS data cube reveals a complex spatial morphology across the 0.1 pc scale of the 3'' UCHII region. Comparison of the nebular emission to Cloudy ionization models shows that the central source must have an effective temperature between about 37000 K and 45000 K with preferred values near 40000 K. Evidence is presented for sharp density variations in the nebula which are interpreted as a clearing of material nearest the central source. High excitation lines of FeIII and SeIV show that the ionization of the nebula clearly changes with distance from the central source. A double lobed kinematic signature (+/- 25 kms) is evident in the Br gamma line map which ...
2009-01-01
Enhanced MALDI-TOF MS Analysis of Phosphopeptides Using an Optimized DHAP/DAHC Matrix
Selecting an appropriate matrix solution is one of the most effective means of increasing the ionization efficiency of phosphopeptides in matrix-assisted laser-desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). In this study, we systematically assessed matrix combinations of 2, 6-dihydroxyacetophenone (DHAP) and diammonium hydrogen citrate (DAHC), and demonstrated that the low ratio DHAP/DAHC matrix was more effective in enhancing the ionization of phosphopeptides. Low femtomole level of phosphopeptides from the tryptic digests of ?-casein and ?-casein was readily detected by MALDI-TOF-MS in both positive and negative ion mode without desalination or phosphopeptide enrichment. Compared with the DHB/PA matrix, the optimized DHAP/DAHC matrix yielded superior sample homogeneity and higher phosphopeptide measurement sensitivity, particularly when multiple phosphorylated peptides were assessed. Finally, the ...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
The use of linear accelerators in radiotherapy is of great importance in Medicine, and according to international recommendations the electron beam dosimetry has to be performed using plane-parallel ionization chambers, previously calibrated in standard gamma radiation fields at accredited laboratories. In this work, calibration methods of plane-parallel ionization chambers used in dosimetry procedures of high energy electron beams of clinical accelerators were presented, tested and intercompared. The experiments were carried out using gamma radiation beams of {sup 60} Co at the Calibration Laboratory of Clinical Dosemeters at IPEN and electron beams od 4 to 16 MeV at the Radiotherapy Department of Hospital Israelita Albert Einstein, Sao Paulo. A method was chosen to be established at IPEN. Proposals of the calibration procedure, calibration certificate and data sheets are presented. (author)
1999-07-01
DEFF Research Database (Denmark)
The aim of the present study was to test a mathematical model of the biochemical processes in the parathyroid glands responsible for the secretion of parathyroid hormone resulting from extracellular calcium reduction. A double exponential curve described the parathyroid hormone secretion induced by rapid lowering of blood-ionized calcium in humans with normal as well as abnormal parathyroid tissue. Our data show that it was possible to establish a simple mathematical model of the parathyroid hormone response to blood-ionized calcium lowering, sufficient to fit experimental data obtained from patients with abnormal and normal parathyroid tissue. The fitted parameters showed no significant differences between patients with insulin-dependent diabetes mellitus and controls. In primary hyperparathyroidism, the parathyroid hormone production and steady-state transport across the cell membrane were increased, probably due to the larger amount of ...
1997-01-01
Disposal of De-ionizer Vessels Highly Contaminated with 14Carbon at SRS
International Nuclear Information System (INIS)
At the Savannah River Site (SRS), nuclear production reactors used de-ionizers to control the chemistry of the reactor moderator during their operation to produce nuclear materials primarily for the weapons program. These de-ionizers were removed from the reactors and stored as a legacy waste with no path to disposal due to the relatively high 14C contamination (i.e., on the order of 20 curies per de-ionizer for 48-50 de-ionizers) and the low disposal limit of 4.2 Ci previously established for the Intermediate Level Vault (ILV). The ILV is considered most appropriate facility within which to dispose these items due to the method of solidifying waste items with cementitious material inside concrete vaults. In previous analyses the 14C ILV disposal limit was established at 4.2 Ci resulting from the use of a very conservative method to analyze the dose received from atmospheric releases of gaseous 14C. ...
2008-01-01
Use of radiosensitivity to identify irradiated fresh poultry products
International Nuclear Information System (INIS)
Microbiological comparison between irradiated and non-irradiated foodstuff has been studied for a long time as a way to detect whether a foodstuff has been irradiated or not. Generally, the proposed methods are based on the fact that ionization select species of bacteria which are recognized to be radioresistant. So reduction or elimination of known radiation sensitive microbes from the normal endogenous microflora could give an indication that the foodstuff has been irradiated, predominance of known radioresistant bacteria should be another indication. In the present work, we try to develop a test based on the radiosensitivity of the bacteria independently of their place. These first experiments show that the determination of radiosensitivity of strains isolated from a product or even of global radioresistance of mesophilic microflora could indicate if this product has been previously submitted to ionizing radiations. (4 tabs).
1990-02-14
The mass dependence of the signal peak height of a Bragg-curve ionization chamber
International Nuclear Information System (INIS)
The Bragg-curve detector of the parallel plate ionization chamber type generates a signal that is a distorted replica of the original Bragg-curve. In result of this distortion, the signal peak height is not only a function of the atomic number of the heavy ion, as it is often stated, but also of the particle mass. This mass effect was studied with the aid of computer simulation, and it was found to be dependent on the Frisch grid to anode gap width and on the detector gas. The charge resolution of the detector is affected very significantly by this mass dependence of the signal peak height. Therefore, a careful selection of the detector gas and the grid to anode gap width is necessary, if good charge resolution over a wide range of heavy ions is required. (orig.).
The effect of neutrals on the performance of plasma opening switches
Energy Technology Data Exchange (ETDEWEB)
The authors address the question of the limitations on voltage and current transfer to loads in magnetic storage systems utilizing microsecond conduction time plasma opening switches. They propose that the limitation of performance results from neutral atoms that are not entrained into the ionized material that is driven by the magnetic field of the rising generator current. Evidence in support of this proposition is gathered from experiments performed on the Ace-4 and Hawk generators. They set forth a theory to describe the effect of neutrals on the electrical performance of plasma opening switches. The neutral gas is assumed to be present in the region between the moving plasma mass and the generator, primarily in the region in which the plasma is injected initially. The essential elements of the theory are a weak photoionization source to seed the gas with a low concentration of electrons, and joule heating accompanied by further ionization ...
1996-12-31
Retention of ring structure in cyclopentane and alkylcyclopentane molecular cations
Energy Technology Data Exchange (ETDEWEB)
All measurements were made with the NBS high-pressure photoionization mass spectrometer. The fractional of C/sub 5/H/sub 10//sup +/ions in a cyclopentane-cyclohexane mixture were determined as a function of pressure in order to define the fraction of the ions which did charge exchange with cyclohexane; i.e. the fraction which remained cyclic after ionization. The data for mixtures of various compositions (2.5 to 10% cyclohexane) are summarized for measurements performed at 10.62 eV: (a) 292K, > 96% cyclic; 347 K, greater than or equal to 94% cyclic; 386 K, 84 +- 4% cyclic; and 412 K, 78 +- 6% cyclic; entropy, enthalpy, and activation energy were determined; 10.49 eV was obtained as the ionization potential of cyclopentane. 1 figure.
1980-01-01
Energy Technology Data Exchange (ETDEWEB)
Long before possible organic effects, exposure to ionizing radiations can provoke anxiety. In front of invisibility, the imagination quickly ignites. The terrorists have perfectly understood it. They are ready to use ionizing radiations as a weapon to remind traumatic images deeply rooted in people's memory. These images induce anxiety with all the clinical expressions connected to it. These symptoms require to be treated because of a possible anarchic development. For that purpose, plans have been elaborated to coordinate the different professional's actions. The coherence of medical management and communication aims to allow the most implicated people to find the way to face the events. When it is not possible, medico-psychological cells permit a specialized care. (author)
2006-08-15
International Nuclear Information System (INIS)
Recent research findings of epidemiologist Alice Stewart suggest that nuclear workers may be at risk of contracting cancer even though their measured occupational doses fall within current safety standards. It is argued that these standards are inappropriate as they are based on extrapolations of studies on survivors of the Hiroshima and Nagasaki explosions. These individuals received single doses of radiation, whereas today's nuclear industry personnel are exposed to low-level ionizing radiation over the length of their working lives. Stewart's team linked low dose occupational exposure to ionizing radiation with an increased risk of cancer in respiratory, digestive and blood-forming tissues. The nuclear industry and United States government agencies hotly contest these assertion with their potentially damaging political and economic consequences. (UK).
1993-05-01
Energy Technology Data Exchange (ETDEWEB)
Recent research findings of epidemiologist Alice Stewart suggest that nuclear workers may be at risk of contracting cancer even though their measured occupational doses fall within current safety standards. It is argued that these standards are inappropriate as they are based on extrapolations of studies on survivors of the Hiroshima and Nagasaki explosions. These individuals received single doses of radiation, whereas today's nuclear industry personnel are exposed to low-level ionizing radiation over the length of their working lives. Stewart's team linked low dose occupational exposure to ionizing radiation with an increased risk of cancer in respiratory, digestive and blood-forming tissues. The nuclear industry and United States government agencies hotly contest these assertion with their potentially damaging political and economic consequences. (UK).
1993-05-15
International Nuclear Information System (INIS)
The book presents a very good account of all aspects of protection from ionizing radiation. The quantities and units are given and defined used in nuclear physics and dosimetry. The effects of ionizing radiation on cells and on man are described. The principles are presented of radiation protection including limits and valid regulations and decrees. Also discussed is internal irradiation and its modelling. A great part of the book is devoted to aspects of monitoring persons, the living and working environment and to the determination of internal contamination. The system of radiation protection in Czechoslovakia is described and some practical questions are discussed of protection during radiodiagnosis and radiotherapy, in the nuclear fuel cycle, in the operation of nuclear power installations and in crack detection. In conclusion a survey is given of the population exposure from various natural and artificial sources. (M.D.). 57 figs., 34 ...
1988-01-01
Energy Technology Data Exchange (ETDEWEB)
An investigation was made of the accumulation of laser damage to transparent polymers irradiated with nanosecond pulses from neodymium and ruby lasers. The damage was investigated by the method of scattering and luminescence in the visible and near ultraviolet parts of the spectrum. It was established that there were two stages in laser damage by repeated irradiation with pulses of intensity below the single-shot damage threshold. An absorbing defect evolved during the first stage in such a way as to create a thermal instability in the surrounding matrix. During the second stage this thermal instability caused spatial growth of laser damage because of propagation of an ionization-inducing absorption wave with a front traveling at the rate governed by the electron component of the thermal conductivity.
1984-04-01
Mass dependence of the signal peak height of a Bragg-curve ionization chamber
Energy Technology Data Exchange (ETDEWEB)
The Bragg-curve detector of the parallel plate ionization chamber type generates a signal that is a distorted replica of the original Bragg-curve. In result of this distortion, the signal peak height is not only a function of the atomic number of the heavy ion, as it is often stated, but also of the particle mass. This mass effect was studied with the aid of computer simulation, and it was found to be dependent on the Frisch grid to anode gap width and on the detector gas. The charge resolution of the detector is affected very significantly by this mass dependence of the signal peak height. Therefore, a careful selection of the detector gas and the grid to anode gap width is necessary, if good charge resolution over a wide range of heavy ions is required.
1985-01-01
Mammary carcinogenesis in the rat after low-dose irradiation
International Nuclear Information System (INIS)
Carcinogenesis is now generally recognized to be an important detrimental effect in man after low dose irradiation. The carcinogenic action of ionizing radiation is clearly demonstrated after exposure to relatively high doses (in excess of 0.5 Gy) but for lower dose levels reliable direct observations are not available. With the introduction of special protocols for the performance of large scale screening programs by mammography the average absorbed dose in glandular tissue in the average breast can be restricted to a value of 3 mGy per mammogram. The risk for tumor induction after exposure to these low doses can never be established from human epidemiology. In order to investigate the risk of repeated exposure to small dose of ionizing radiation the induction of mammary tumors has been investigated in rats of the WAG/Rij strain after single and fractionated irradiations with gamma-rays. (author). 8 refs., 3 figs.
1992-07-12
Ionizing radiation is a potent inducer of mitotic recombination in mouse embryonic stem cells
British Library Electronic Table of Contents (United Kingdom)
Maintenance of genomic integrity in embryonic cells is pivotal to proper embryogenesis, organogenesis and to the continuity of species. Cultured mouse embryonic stem cells (mESCs), a model for early embryonic cells, differ from cultured somatic cells in their capacity to remodel chromatin, in their repertoire of DNA repair enzymes, and in the regulation of cell cycle checkpoints. Using 129XC3HF1 mESCs heterozygous for Aprt, we characterized loss of Aprt heterozygosity after exposure to ionizing radiation. We report here that the frequency of loss of heterozygosity mutants in mESCs can be induced several hundred-fold by exposure to 5-10Gy of X-rays. This induction is 50-100-fold higher than the induction reported for mouse adult or embryonic fibroblasts. The primary mechanism underlying the...
2011-01-01
Ionized gas and radio emission in the barred Seyfert galaxy NGC 5728
International Nuclear Information System (INIS)
This paper reports extensive new optical and radio observations of NGC 5728, emphasizing the central regions. Deep photographs revealing detail in the faint spiral arms are briefly discussed. Broad-band UBV CCD images obtained to examine the colors of the stellar populations that comprise the bar and central ring are presented. The velocity field and emission maps obtained from imaging spectroscopic measurements in the H-alpha emission line are discussed. Conventional long-slit spectra covering the ionized gas in the nuclear region are described. Detailed maps of the radio emission in the central regions of NGC 5728 are presented. These combined data provide considerable evidence for the inflow of gas into the nuclear region, in response to the nonaxisymmetric gravitational potential of the bar. The possible relation of this phenomenon to the Seyfert nature of NGC 5728 is also considered. 48 references.
International Nuclear Information System (INIS)
The main objectives of research in the field of health effects at the Belgian Nuclear Research Centre SCK-CEN are: (1) to study cancer mortality and morbidity in nuclear workers in Belgium; (2) to document the feasibility of retrospective cohort studies in Belgium; (3) to participate in the IARC study; (4) to elucidate the mechanisms of the effects of ionizing radiation on the mammalian embryo during the early phases of its development; (5) to assess the genetic risks of material exposure to ionizing radiation; (6) to elucidate the cellular mechanisms leading to brain damage after prenatal irradiation; (7) to advise authorities and to provide the general population with adequate information concerning the health risk arising from radiation exposure. Progress and major achievements in these topical areas for 1997 are reported.
Effect of ionizing radiation on the properties of PLA packaging materials
International Nuclear Information System (INIS)
Poly(lactic acid) (PLA) is attractive as a substitute for classical polymer packaging material due to its biodegradability and sufficient mechanical and barrier properties. Presented research was focused on the changes of basic mechanical parameters after ionizing irradiation performed with doses in the range of 2.5-25 kGy, commonly used in radiation sterilization and preservation of foods. Two commercial available PLA packaging films were tested. The influence of radiation dose on the mechanical properties - tensile strength and elongation were determined using standardized methods. Radiation resistance of PLA is sufficient for packaging applications. The investigations of gas products of radiolysis of PLA have been made by gas chromatography after electron beam (EB) irradiations. (authors)
Detection of irradiated chicken by ESR spectroscopy of bone
Energy Technology Data Exchange (ETDEWEB)
Ionizing radiation has been used to treat poultry to remove harmful microorganisms, mainly Salmonella, which contaminates chicken, goose and other fresh and frozen poultry. This microorganism is sensitive to low dose radiation. Thus, irradiating these foods with doses between 1 to 7 kGy results in a large reduction of bacteria. Since it is necessary to determine whether irradiation has occurred and to what extend, this work studied the signal produced by ionizing radiation within the hard crystalline matrix of chicken`s bone to establish a control method. Chicken`s drumsticks were irradiated and bones separated from flesh were lyophilized and milled. ESR spectrum was then obtained. The ESR signal increased linearly with dose over the range 0.25 to 8.0 kGy. Free radicals evaluated during 30 days after irradiation showed stable in this period. (Author).
1995-10-01
British Library Electronic Table of Contents (United Kingdom)
Photoelectron resonance capture ionization aerosol mass spectrometry (PERCI-AMS) has been applied to the analysis of proxies for marine aerosols with and without ozone; proxies used were mixed oleic acid-amino acid particles. The mechanism of ion formation for serine (104 m/z), glutamic acid (146 m/z), and phenylalanine (164 m/z) was dissociative electron attachment. This corresponds to loss of the hydrogen atom only, allowing for straightforward identification of the free amino acids. No ozonolysis products for the free amino acids were observed, even at high concentrations of ozone (500 ppm for 19 s). The direct detection of a novel gas-phase hydrated anion, [serine + H2O-H]-, is described. These preliminary results suggest that PERCI-AMS may provide an effective, simple and direct onlin...
2008-01-01
Correlation effects in partially ionized mass asymmetric electron-hole plasmas
The effects of strong Coulomb correlations in dense three-dimensional electron-hole plasmas are studied by means of unbiased direct path integral Monte Carlo simulations. The formation and dissociation of bound states, such as excitons and bi-excitons is analyzed and the density-temperature region of their appearance is identified. At high density, the Mott transition to the fully ionized metallic state (electron-hole liquid) is detected. Particular attention is paid to the influence of the hole to electron mass ratio $M$ on the properties of the plasma. Above a critical value of about M=80 formation of a hole Coulomb crystal was recently verified [Phys. Rev. Lett. {\\bf 95}, 235006 (2005)] which is supported by additional results. Results are related to the excitonic phase diagram of intermediate valent Tm[Se,Te], where large values of $M$ have been observed experimentally.
2007-01-01
Comparative evolution of various CCD image sensors hardening techniques with ionizing radiation
International Nuclear Information System (INIS)
This paper reviews various techniques to harden Charged Coupled Device (CCD) sensors and the results after irradiation of three Thomson n buried channel CCDs having a different degree of hardening. It describes the major irradiation effects on CCD performances and it makes a comparison of the results between the different hardening levels. It shows good results on dark voltage after ionizing radiation for TH 7863M device hardened both by design and by operating conditions (MPP mode) with respect to the standard device TH 7863A. The irradiations were performed with "6"0Co or X-ray (10 keV) sources on devices in operating mode. (author). 3 refs., 8 figs.
Clinical application of dosimetry in electron beam therapy
International Nuclear Information System (INIS)
In everyday radiotherapy we must carry out the determination of absorbed dose measurement according to JARP's protocol. We explained an outline of JARP's 1974 and 1986 protocol in electron beam therapy, and mentioned it about the matter that should examined. To use it easily in clinic, a simplified procedure based on precisely to JARP's 1986 protocol is practical, the character of this procedure settles briefly the determination of mean incident energy of electron beams and get ready to table of ionization to absorbed dose conversion factor for various ionization chamber. Also, this procedure almost not influence on the accuracy of determination. We described systematically practical procedure for requisite absorbed dose calculation in a patient in electron beam therapy. (author).
Atomic processes in high temperature plasmas
International Nuclear Information System (INIS)
Much theoretical and experimental efforts have been expended in recent years to study those atomic processes which are specially relevant to understanding high temperature laboratory plasmas. For magnetically confined fusion plasmas, the temperature range of interest spans from the hundreds of eV at plasma edges to 10 keV at the center of the plasma, where most of the impurity ions are nearly fully ionized. These highly stripped ions interact strongly with electrons in the plasma, leading to further excitation and ionization of the ions, as well as electron capture. Radiations are emitted during these processes, which easily escape to plasma container walls, thus cooling the plasma. One of the dominant modes of radiation emission has been identified with dielectronic recombination. This paper reviews this work.
1990-01-01
A Fast Ionization Chamber for Fission Cross-Section Measurements at n(_)TOF
International Nuclear Information System (INIS)
An ionization chamber with fast timing properties was built at CERN for measuring fission cross-sections of minor actinides at the n(_)TOF neutron beam. The design of this new chamber and of the front-end electronics was optimized to match the innovative features of the n(_)TOF facility, in particular the high instantaneous neutron flux and low background. For the most radioactive isotopes, a special version of the chamber, designed according to the ISO2919 standards, was built in order to comply with the radioprotection requirements at CERN. The detector and front-end electronics are here described, together with the simulated and measured response to fission fragments and #alpha#-particles. The performances of the chamber during the first measurement campaign at n(_)TOF are presented, focusing in particular on the fast time response, the good background rejection capability, low-background and high detection efficiency.
2008-09-01
Structural transformations in Sc/Si multilayers irradiated by EUVlasers
Energy Technology Data Exchange (ETDEWEB)
Multilayer mirrors for the extreme ultraviolet (EUV) are keyelements for numerous applications of coherent EUV sources such as newtabletop lasers and free-electron lasers. However the field ofapplications is limited by the radiation and thermal stability of themultilayers. Taking into account the growing power of EUV sources thestability of the optics becomes crucial. To overcome this problem it isnecessary to study the degradation of multilayers and try to increasetheir temporal and thermal stability. In this paper we report the resultsof detailed study of structural changes in Sc/Simultilayers when exposedto intense EUV laser pulses. Various types of surface damage such asmelting, boiling, shockwave creation and ablation were observed asirradiation fluencies increase. Cross-sectional TEM study revealed thatthe layer structure was completely destroyed in the upper part ofmultilayer, but still survived below. The layers adjacent tothe substrateremained intact even ...
2007-08-21
British Library Electronic Table of Contents (United Kingdom)
SommarioScopo In questo studio riportiamo i dati relativi all'ablazione percutanea con Radiofrequenza (RF) di HCC e trombosi neoplastica dei vasi portali. Pazienti e metodi Dieci pazienti (pz) cirrotici, 7 maschi e 3 femmine, eta media 68 anni, con 10 noduli di HCC e trombosi neoplastica dei vasi portali sono stati sottoposti ad ablazione percutanea con RF del trombo neoplastico e dell'HCC. La RF veniva ritenuta efficace quando alla TC con mdc si osservava la necrosi completa dell'HCC e al Color Doppler si osservava la ricanalizzazione completa dei vasi portali. Risultati La necrosi completa dell'HCC e la ricanalizzazione completa dei vasi portali si osservava in 7 (70%) dei 10 pazienti. Nei rimanenti 3 (30%) la necrosi dell'HCC e la ricanalizzazione dei vasi portali non risultavano comple...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
The Zollinger-Ellison syndrome (ZES) is taken as an example of the diagnostic and therapeutic strategy in gastro-entero-pancreatic endocrine tumours, given the standard characteristics of this procedure, whatever the nature of the primitive tumour. Management of ZES includes: anatomical localization of gastrinoma and of possible metastases, in 60 % of cases this step conditioning therapeutic indications and chances of cure; search of a type 1-multiple endocrine neoplasia (MEN A), in 25 % of cases; therapeutic indications: ablative surgery with curative intent in case of gastrinoma and of resectable liver metastases, palliative treatment otherwise: anti-secretory drugs, somatostatin analogues, chemotherapy and interferon {alpha}; long-term follow-up of patients with resected tumour. At each step, somatostatin receptor scintigraphy with indium 111-pentetreotide does play a pivotal role. (author). 110 refs.
1996-12-31
Energy Technology Data Exchange (ETDEWEB)
Both (001)- and (111)-oriented CeO[sub 2] thin films have been grown on amorphous fused silica (SiO[sub 2]) substrates by ion-beam assisted pulsed laser ablation of a polycrystalline CeO[sub 2] target. Using 200 eV Ar[sup +] ions incident at 55[degree] to the substrate normal, the preferred orientation for CeO[sub 2] film growth is (001) at room temperature, but changes to (111) for temperatures [ge]300 [degree]C. Furthermore, the ion-beam assisted CeO[sub 2] films exhibit strong in-plane crystallographic alignment. In contrast, CeO[sub 2] films grown without ion-beam assistance exhibit a mixture of polycrystalline orientations with the relative amounts depending on growth temperature. Under optimum conditions, off-normal-incidence Ar[sup +] ions produce a (111)-oriented crystalline CeO[sub 2] film that is aligned with respect to a single in-plane axis, on an amorphous substrate.
1994-10-17
High tunability of pulsed laser deposited Ba0.7Sr0.3TiO3 thin films on perovskite oxide electrode
British Library Electronic Table of Contents (United Kingdom)
Ferroelectric thin films such as BST, PZT and PLZT are extensively being studied for the fabrication of DRAMS since they have high dielectric constant. The large and reversible remnant polarization of these materials makes it attractive for nonvolatile ferroelectric RAM application. In this paper we report the characterization of Ba0.7Sr0.3TiO3 (BST) thin films grown by pulsed laser ablation on oxide electrodes. The structural and electrical properties of the fabricated devices were studied. Growth of crystalline BST films was observed on La0.5Sr0.5CoO3 (LSCO) thin film electrodes at relatively low substrate temperature compared to BST grown on PtSi substrates. Electrical characterization was carried out by fabricating PtSi/LSCO/BST/LSCO heterostructures. The leakage current of the heteros...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Pulsed laser deposition (PLD) is known for its capacity to reproduce a target composition on a substrate. The authors have used this deposition technique to produce thin films of transition metal chalcogenides. However, the deposits were always deficient in Te relative to the starting material (composed by a refractory metal (niobium) and a chalcogene (tellurium)). Variations of the interreticular distances have been observed with respect to fluence and substrate temperature. The authors show that spatial composition of the films is determined by a degree of crystallinity of deposit and by the reaction of formation of Te{sub 2} molecule within laser induced plume. Two kinds of deposits have been obtained: Nb{sub 5}Te{sub 4}-type thin films which have a one-dimensional structure and NbTe{sub 2}-type thin films which have a two-dimensional structure. While NbTe{sub 2} films have been realized by sputtering, it is the first time that Nb{sub 5}Te{sub 4} films have been deposited.
1996-12-31
Calibration-Free Laser-Induced Breakdown Spectroscopy: State of the art
Energy Technology Data Exchange (ETDEWEB)
The aim of this paper is offering a critical review of Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS), the approach of multi-elemental quantitative analysis of LIBS spectra, based on the measurement of line intensities and plasma properties (plasma electron density and temperature) and on the assumption of a Boltzmann population of excited levels, which does not require the use of calibration curves or matrix-matched standards. The first part of this review focuses on the applications of the CF-LIBS method. Quantitative results reported in the literature, obtained in the analysis of various materials and in a wide range of experimental conditions, are summarized, with a special emphasis on the departure from nominal composition values. The second part is a discussion of the simplifying assumptions which lie at the basis of the CF-LIBS algorithm (stoichiometric ablation and complete atomization, thermal equilibrium, homogeneous plasma, thin ...
2010-01-15
Calibration-Free Laser-Induced Breakdown Spectroscopy: State of the art
International Nuclear Information System (INIS)
The aim of this paper is offering a critical review of Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS), the approach of multi-elemental quantitative analysis of LIBS spectra, based on the measurement of line intensities and plasma properties (plasma electron density and temperature) and on the assumption of a Boltzmann population of excited levels, which does not require the use of calibration curves or matrix-matched standards. The first part of this review focuses on the applications of the CF-LIBS method. Quantitative results reported in the literature, obtained in the analysis of various materials and in a wide range of experimental conditions, are summarized, with a special emphasis on the departure from nominal composition values. The second part is a discussion of the simplifying assumptions which lie at the basis of the CF-LIBS algorithm (stoichiometric ablation and complete atomization, thermal equilibrium, homogeneous plasma, thin ...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
A newly constructed Fourier transform microwave spectrometer has been used to record the pure rotational spectra of four isotopomers of SrS ({sup 88}Sr{sup 32}S, {sup 87}Sr{sup 32}S, {sup 86}Sr{sup 32}S, and {sup 88}Sr{sup 34}S) between 6 and 26 GHz. The molecules were produced by reacting laser ablated strontium with carbonyl sulfide (0.1% in argon). Pure rotational transitions in the ground, first and second vibrational states have been observed. The data set has enabled a multi-isotopomer fit. Born-Oppenheimer breakdown terms for both atoms have been determined. The {sup 87}Sr nuclear quadrupole coupling constant in {sup 87}Sr{sup 32}S has been determined for the first time.
2007-12-06
Application of spectroscopic techniques for the study of paper documents: A survey
International Nuclear Information System (INIS)
For many centuries paper was the main material for recording cultural achievements all over the world. Paper is mostly made from cellulose with small amounts of organic and inorganic additives, which allow its identification and characterization and may also contribute to its degradation. Prior to 1850, paper was made entirely from rags, using hemp, flax and cotton fibres. After this period, due to the enormous increase in demand, wood pulp began to be commonly used as raw material, resulting in rapid degradation of paper. Spectroscopic techniques represent one of the most powerful tools to investigate the constituents of paper documents in order to establish its identification and its state of degradation. This review describes the application of selected spectroscopic techniques used for paper characterization and conservation. The spectroscopic techniques that have been used and will be reviewed include: Fourier-Transform Infrared spectroscopy, Raman spectroscopy, Nuclear Magnetic ...
2009-06-01
The aim of this work was to study the possibility of producing a fast switching optical thin film device to react to laser radiation in the visible/near infrared region of the spectrum. The switching mechanism was to be thermally driven. A computer program was written to enable the effects of changes of the refractive index of a component of a multilayer thin film stack to be modelled. Attempts to use the phase transition in vanadium dioxide were unsuccessful because, in the spectral region of interest, the 'open-state' absorption was too great. A class of materials known as 'the bronzes' was identified as being potentially useful. Attempts were made to produce thin films of bronze compounds of vanadium, tungsten and molybdenum by the techniques of conventional thermal evaporation and laser ablation for further studies. The former technique appeared to suffer from problems of decomposition of the source material. The latter technique showed greater promise although ...
1995-01-01
Energy Technology Data Exchange (ETDEWEB)
The purpose of this paper is to report the personal experience with helical CT evaluation of hepatocellular carcinoma treated with various percutaneous interventional procedures. From December 1996 to September 1998 it were examined with helical CT 41 patients (73 nodules in all) with hepatocellular carcinoma treated with percutaneous ablation therapies: conventional ethanol injection in 18 subjects (31 nodules), one-shot ethanol injection 3 (8 nodules), radiofrequency thermal ablation in 16 (25 nodules), and combined chemo embolization and ethanol injection in 4 (9 nodules). CT performed was 4-27 days after the last session, acquiring biphasic volumetric images in 14 patients and triphasic volumetric images in 27. A second treatment with subsequent CT study was performed for 28 lesions; 15 underwent 3 serial studies and 6 underwent 4 studies. Compared with pretreatment findings, the diameter was unchanged in 62% of the nodules and increased in ...
1999-12-01
UK PubMed Central (United Kingdom)
The titers of several preparations of kuru. Creutzfeldt-Jacob disease, and scrapie viruses were reduced by only 1/10th or less by high doses of gamma radiation of 50 kGy and by only 1/10th-1/1000th...Full Text Available
1978-12-01
Total dose hardening of SIMOX buried oxides for fully depleted devices in rad-tolerant applications
International Nuclear Information System (INIS)
A total dose hardening treatment is applied to SIMOX buried oxides. Total ionizing dose radiation testing is performed on fully-depleted transistors fabricated on both hardened and non-hardened substrates. At 200 krads x-ray dose, the front gate shift is reduced from -0.7 to -0.2 V for FETs built on the hardened wafers.
1996-07-15
Spontaneous radiation decay of weakly bound system in externa field
International Nuclear Information System (INIS)
A new channel of nonlinear ionization of quantum system in a strong laser field is discussed. The probability of spontaneous radiation decay from the ground state in a short-range potential to the final Volkov wave function, is calculated by the first order of the perturbation theory. It is shown that this process at high intensities of the laser field will be comparable with the high harmonic generation. (orig.)
2001-02-01
Sources of X-rays in school; Zrodla promieniowania rentgenowskiego w szkole
Energy Technology Data Exchange (ETDEWEB)
Exposure of teachers of physics to X-radiation emitted by instruments which are used for demonstrating rarefied gas discharges during physics lessons at secondary schools is discussed. The measurements performed provide an explicit evidence that an effective, annual exposure dose under the most unfavorable conditions does not exceed admissible levels according to Polish regulations pertaining to persons non-occupationally exposed to ionizing radiation. (author). 3 refs,1 fig.
1996-12-31
Self-simulating motion of an ionized gas expelled by a magnetic piston
Energy Technology Data Exchange (ETDEWEB)
The paper deals with a model in which the motion of a gas in plasma accerators and high-curent discharges in the present of a skin effect is treated as expulsion by a 'magnetic piston' under the action of surface current flow. Specifically examined is the situation where the initial gas pressure is negligible in comparison with the magnetic pressure, and the motion of the gas may be treated as a self-simulating one. A system of hydrodynamic equations of the problem is derived and integrated by Adam's method. Results are plotted and discussed.
1980-01-01
Searches for Fast Radio Transients
We discuss optimal detection of fast radio transients from astrophysical objects while taking into account the effects of propagation through intervening ionized media, including dispersion, scattering and scintillation.Our analysis applies to the giant-pulse phenomenon exhibited by some pulsars, for which we show examples, and to radio pulses from other astrophysical sources, such as prompt radio emission from gamma-ray burst sources and modulated signals from extra-terrestrial civilizations.
2003-01-01
Room air quality. Raumluftqualitaet
Energy Technology Data Exchange (ETDEWEB)
Room air quality and thus thermal comfort for the occupiers in closed spaces depend on several factors: temperature and humidity of the air, temperature of the surrounding surfaces, content of foreign matter of the air, acoustical perceptions, electric fields and ions as well as colours and light. Air humidification, cleaning and ionization largely contributes to improved room air quality. The article goes into problems of too dry and polluted air as well as into measures with which these problems can be solved. (BWI).
1990-12-01
Energy Technology Data Exchange (ETDEWEB)
It may be necessary to reduce microbiological contamination of crude drugs (medicinal plants or their parts like roots, leaves, flowers). This can be done by treating the drugs with ionizing radiation. Meethods for detection of such an irradiation were developed. It could be pointed out that measurements of luminescence, viscosity and electron spin resonance were suitable for specific drugs, but not for all drugs. (orig.).
1992-09-01
Radiation higienization possibility and perspectives
International Nuclear Information System (INIS)
Food irradiation is the process of exposing food to an ionizing energy to kill harmful bacteria and other organisms and extend shelf-life. It is a safe process and has been approved by some 50 countries worldwide and applied commercially in the USA, Japan, China and several European countries for many years. Trends law regulations and new applications in Europe and another countries has been described. (author)
2005-09-07
Radiation hazards from medical applications
International Nuclear Information System (INIS)
An introduction is presented on the radiation hazards connected with biomedical radiography and nuclear medicine. The frequency of radiodiagnostic efforts was rather high in the Netherlands. This was reduced considerably by abolishing the thorax screening of the population. About diagnostic nuclear medicine less can be said because far fewer numerical data are available. An exposition of genetically and somatically significant doses and how to compute them is given. The drawing up of a profit versus risk evaluation for medical applications of ionizing radiations is recommended. (Auth.).
1980-05-31
Physics of thermal gaseous nebulae
Energy Technology Data Exchange (ETDEWEB)
Much of the material presented in this book derived originally from the series ''Physical Processes in Gaseous Nebulae'' initiated at the Harvard College Observatory in the 1930's. The subject of gaseous nebulae, which offers opportunities for studies of stellar evolution, should be of interest to atomic physicists, spectroscopists, plasma experts, and to observers and theoreticians alike for the study of attenuated ionized gases.
1984-01-01
Particle identification through the measurement of the Bragg curve centroid
Energy Technology Data Exchange (ETDEWEB)
A new method of particle identification of heavy ions through the measurement of the Bragg curve centroid and particle energy has been developed using a gas ionization chamber with a resistive anode layer. Z-resolutions comparable to the conventional ..delta..E-E counter telescope could be rather easily attained.
1983-07-01
Particle identification through the measurement of the Bragg curve centroid
International Nuclear Information System (INIS)
A new method of particle identification of heavy ions through the measurement of the Bragg curve centroid and particle energy has been developed using a gas ionization chamber with a resistive anode layer. Z-resolutions comparable to the conventional #DELTA#E-E counter telescope could be rather easily attained. (orig.).
Particle identification by modified Bragg-curve centroid detection
Energy Technology Data Exchange (ETDEWEB)
A new article identification method based on the measurement of Bragg-curve centroids using a gas-filled ionization chamber has been improved for detection of low-energy particles around 1 MeV per nucleon by introducing a nonuniform distribution of resistance on the anode electrode. Almost the same quality of Z-resolutions as in the conventional ..delta..E-E method could be obtained up to Z=19.
1987-03-01
Normal and abnormal neuronal migration during brain development
International Nuclear Information System (INIS)
Conceptual and factual advances in understanding neuronal migration in the past two decades have provided new insight into the pathogenesis of brain malformations at the cellular, molecular, and functional levels. Some of these results may have direct implications in understanding the consequences of ionizing radiation on the fetal central nervous system in utero. (orig.).
Nitrogen isotope identification by Bragg-curve spectroscopy
Energy Technology Data Exchange (ETDEWEB)
Projectilelike fragments following the 80 MeV /sup 16/O+/sup 27/Al reaction have been detected using a Bragg-curve spectroscopy ionization chamber (BCS-IC). The atomic number is deduced from the Bragg-peak amplitude. Nitrogen isotopes are clearly resolved using either range or energy loss data. This is the first application of the BCS method for complete ion identification in a heavy-ion-induced reaction.
1984-07-14
Nitrogen isotope identification by Bragg-curve spectroscopy
International Nuclear Information System (INIS)
Projectilelike fragments following the 80 MeV "1"6O+"2"7Al reaction have been detected using a Bragg-curve spectroscopy ionization chamber (BCS-IC). The atomic number is deduced from the Bragg-peak amplitude. Nitrogen isotopes are clearly resolved using either range or energy loss data. This is the first application of the BCS method for complete ion identification in a heavy-ion-induced reaction.
Molecular events involved in ionizing radiation induced skin carcinogenesis
International Nuclear Information System (INIS)
The process of mouse skin tumor formation is subdivided into three operational stages. These stages include initiation, promotion and progression. Ionizing radiation has been found to be a weak initiating agent in the production of malignant squamous cell carcinomas, a complete carcinogen and an agent effective in causing tumor progression. Four skin tumor histologies have been seen with ionizing radiation: benign papillomas, squamous (SCC) and basal (BCC) cell carcinomas and fibrosarcomas. Distinct non-ras transforming genes have been detected in radiation initiated SCCs. A benign papilloma cell line (308) was used as a model system to study ionizing radiation induced progression. A variant 308 cell line (308 10 Gy 5) derived by irradiation of the parental 308 cell has been characterized. The 308 10 Gy 5 cells unlike the parental 308 cells from malignant tumors in athymic nude mice upon subcutaneous injection. The variant ...
Lamp system for uniform semiconductor wafer heating
Energy Technology Data Exchange (ETDEWEB)
A lamp system with a very soft high-intensity output is provided over a large area by water cooling a long-arc lamp inside a diffuse reflector of polytetrafluorethylene (PTFE) and titanium dioxide (TiO.sub.2) white pigment. The water is kept clean and pure by a one micron particulate filter and an activated charcoal/ultraviolet irradiation system that circulates and de-ionizes and biologically sterilizes the coolant water at all times, even when the long-arc lamp is off.
2001-01-01
Highly efficient ion source for analysis of transuranium elements
Energy Technology Data Exchange (ETDEWEB)
Results are described of the study of the analytical applicability of a highly efficient ion source developed for a mass spectrometer. Its ionizer is in the form of a partially closed cavity with a small aperture for leading out ions, heated to a high temperature. The new ion source increases the sensitivity of the apparatus in operations with transuranium elements by almost two orders of magnitude. It is possible to perform isotopic analyses with a high salt content in the sample, and to study the characteristics of nuclear fuel, even without chemical separation of the sample elements.
1987-01-01
Efficient higher-order derivatives of the hypergeometric function.
Energy Technology Data Exchange (ETDEWEB)
Various physics applications involve the computation of the standard hypergeometric function {sub 2}F{sub 1} and its derivatives. Because it is not an intrinsic in the common programming languages, automatic differentiation tools will either differentiate through the code that computes {sub 2}F{sub 1} if that code is available or require the user to provide a hand-written derivative code. We present options for the derivative computation in the context of an ionization problem and compare the approach implemented in the Diamant library to standard methods.
2008-01-01
International Nuclear Information System (INIS)
The decree refers to conditions of irradiation of food and its components for radappertization and radurization using gamma radiation from cobalt 60 or cesium 137, X radiation or electron beam up to maximum total medium absorbed dose 10 kGy.
2003-03-04
Bragg-curve spectroscopy at high rates
Energy Technology Data Exchange (ETDEWEB)
The performance of a Bragg ionization chamber has been investigated as a function of the counting rate with approx.= 5 MeV/amu /sup 32/S beams: up to approx.= 20 kHz the energy resolution is below 0.9% and the Z resolving power is more than 50. (orig.).
1986-03-01
Bragg curve spectroscopy in a 4? geometry
Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4? geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon.
1991-02-01
Bragg curve spectroscopy in a 4. pi. geometry
Energy Technology Data Exchange (ETDEWEB)
Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4{pi} geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon. (orig.).
1991-02-01
Bragg curve spectroscopy in a 4#pi# geometry
International Nuclear Information System (INIS)
Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4#pi# geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon. (orig.).
Energy Technology Data Exchange (ETDEWEB)
A new method named 'Bragg curve spectroscopy', based on the Bragg curve of the heavy ion being stopped in a gaseous ionization chamber, has been developed for identifying the particle and measuring its energy. The design of such a chamber and the experience obtained with chamber using various kinds of fast heavy ions are described. In conclusion, several problems to be solved in this method are pointed out.
1982-05-01
International Nuclear Information System (INIS)
A new method named 'Bragg curve spectroscopy', based on the Bragg curve of the heavy ion being stopped in a gaseous ionization chamber, has been developed for identifying the particle and measuring its energy. The design of such a chamber and the experience obtained with chamber using various kinds of fast heavy ions are described. In conclusion, several problems to be solved in this method are pointed out. (orig.).
Biological effects and health risks following to the exposition to ionizing radiation
International Nuclear Information System (INIS)
Late somatic and genetic radiation effects are imperfectly understood, particularly in the human species. However the available information is sufficient to draw reasonably precise risk estimates in man for many types of damage by means of scientifically justifiable procedures and with the necessary caution. This overall absolute risk of major somatic and genetic damage may be set at around 10"-"4/rad of chronic whole-body doses.
1976-01-01
Analyses of superficial and depth doses in intraoral radiology
Energy Technology Data Exchange (ETDEWEB)
In this work dosimetric analysis using thermoluminescence technique to study the beams characteristics of x-rays employed in dental radiology has been carried out. The obtained results with CaSO{sub 4}:Dy thermoluminescent dosimeters (TLD) were compared to the doses obtained with parallel-plates ionization chamber. Dosimetric evaluations were also done using radiographic films of large dimensions. The x-rays equipments analyzed were installed in the radiological services of Odontology Department of Sergipe Federal University (U.F.S.). Depending on the anatomical region to be examined the proper exposure time was select, for a fix voltage of 70 kV. The results with TLD and ionization chamber have been determined to female and male individuals. The intraoral regions analysed were the peri apical of the incisors, molar and pre-molar teeth and the occlusive region. These regions were simulated using acrylic plates absorbers installed on the film ...
2006-07-01
Adiabatic theory of Wannier threshold laws and ionization cross sections
Energy Technology Data Exchange (ETDEWEB)
The Wannier threshold law for three-particle fragmentation is reviewed. By integrating the Schroedinger equation along a path where the reaction coordinate R is complex, anharmonic corrections to the simple power law are obtained. These corrections are found to be non-analytic in the energy E, in contrast to the expected analytic dependence upon E.
1994-12-31
Adiabatic angular wave functions in the atomic ionization proplem
Energy Technology Data Exchange (ETDEWEB)
Angular wave functions are investigated which describe the motion of two electrons in the field of a nucleus at fixed equal distances from electrons to the nucleus. Calculation methods are considered that include matching of power series and expansion in series of Legendre polynomials. Asymptotic properties of solutions at small large distances are determined.
1984-01-01
Absolute fission rates in the FFTF
Energy Technology Data Exchange (ETDEWEB)
The part of the FFTF Reactor Characterization Program reported in this paper is a measurement of absolute fission rates of eight major fuel isotopes at two different positions within the reactor. The instruments employed in these tests were fission ionization chambers for which the absolute efficiency and fissionable deposit mass assay have been rigorously established.
1981-06-01
Energy Technology Data Exchange (ETDEWEB)
A simple and continuous model for the on-state current of polysilicon thin-film transistors, suitable for implementation in circuit simulators, is presented. The model includes the potential barrier at the grain boundaries, the channel length modulation and the excess current due to impact ionization. Comparison between measured output characteristics and the model shows excellent agreement over wide range of bias voltages and for devices with different gate lengths.
2005-01-01
Low temperature partly ionized plasma in magnetic fusion devices: Present status and prospects
Energy Technology Data Exchange (ETDEWEB)
The most striking achievement in magnetic fusion experiments during last few years was the discovery of plasma detachment from material targets, a much needed effect for plasmas with high power fusion parameters. Due to the very low heat loads on the targets observed in these regimes and potentially low erosion of the targets, detached regimes look attractive from the International Thermonuclear Experimental Reactor (ITER) design point of view. Thus the author has experimental proof for the possibility for a co-existence of fusion relevant hot plasma in the core and a low temperature partly ionized plasma at the edge of magnetic fusion device. Although somewhat similar behavior of edge plasma was considered theoretically even before plasma detachment was found experimentally, it was not clear in the beginning how these theoretical and experimental findings would fit together. Now, after a few years of intensive additional experimental and theoretical studies, a ...
1998-12-31
Energy Technology Data Exchange (ETDEWEB)
The aim of this study was to investigate whether sub-ablative pulsed C0{sub 2} laser (1 0,6 {mu}m) irradiation is capable of reducing the susceptibility of the dental enamel to demineralization, and thus achieving a potential caries-protective effect. The crowns of 51 bovine front teeth, embedded in acrylic resin and polished until exposure of flat enamel surface, were used. The samples were cut in cubes of 10x10 mm, and totally coated with acid-resistant nail varnish, except for an enamel exposed window of 16 mm square. Three groups (n=17) were obtained: control group (CG) not irradiated; group laser A (LA) and group laser B (LB) where the samples were irradiated. The conditions were 60 mJ, 100 Hz, 0,3 J/cm{sup 2} for LA and 135 mJ, 10 Hz, 0,7 J/cm{sup 2} for LB. Two samples of each group were submitted to SEM analysis and fifteen to demineralization in 3 ml acetate buffer solution (0,1 mol/L) with pH 4,5 for 24h at 37 deg C, with regular agitation. After the ...
2005-07-01
VUV efficiency and radiant emittance characterization of xenon positive column discharges
Energy Technology Data Exchange (ETDEWEB)
The pure xenon dc positive column discharge has been characterized for various xenon pressures, currents, and discharge tube radii. The absolute output at the 147 nm resonance transition has been measured using two independent techniques to yield the radiant emittance at 147 nm (power per unit surface area). The efficiency of 147 nm production is obtained by combining the measured radiant emittance with the measured electrical power per unit length deposited in the gas. The radiant emittance and the efficiency are the two principle figures of merit for characterizing the discharge as a source of VUV radiation. It is observed that the trends in efficiency and radiant emittance change substantially when the discharge transitions from two-step electron impact excitation/ionization at higher pressures to single-step electron impact ionization at lower pressures. Modeling of the xenon positive column discharge yields radiant emittance and efficiency ...
1996-12-31
Unification of Luminous Type 1 Quasars through CIV Emission
Using a sample of 30,000 quasars from SDSS-DR7, we explore the range of properties exhibited by high-ionization, broad emission lines, such as CIV 1549. Specifically we investigate the anti-correlation between L_UV and emission line EQW (the Baldwin Effect) and the "blueshifting" of high-ionization emission lines. The blueshift of the CIV emission line is nearly ubiquitous, with a mean shift of 810 km/s for radio-quiet (RQ) quasars and 360 km/s for radio-loud (RL) quasars, and the Baldwin Effect is present in both RQ and RL samples. Composite spectra are constructed as a function of CIV emission line properties in attempt to reveal empirical relationships between different line species and the SED. Within a two-component disk+wind model of the broad emission line region (BELR), where the wind filters the continuum seen by the disk component, we find that RL quasars are consistent with being dominated by the disk component, while BALQSOs are ...
2010-01-01
The Development of a Neutral Particle Detector for Observations of the Thermosphere
One of the least understood regions of the upper atmosphere is the thermosphere, principally due to the difficulty of making observations. The neutral atmosphere is known to be highly variable, and its composition and density varies by several orders of magnitude due to solar activity, diurnal cycles, latitude, geomagnetic activity, and gravity waves. In the past, most in-situ measurements of the neutral atmosphere have utilized detectors that are dependent on arrival angle and energy accommodation of incoming species, so that information related to nascent velocity distribution and reactive species abundances is often masked. This paper will review design concepts and laboratory tests related to the development of a novel open-ionizer, neutral particle detector for space environment measurements which can overcome these limitations. The sensor features a very large field-of-view suitable for sounding rocket missions. This time-of-flight instrument uses ...
2006-12-01
Energy Technology Data Exchange (ETDEWEB)
Food irradiation is the processing of food products by ionizing radiation in order, among other things, to control food borne pathogens, reduce microbial load and insect infestation, inhibit the germination of root crops, and extend the durable life of perishable products. Irradiation of dried food ingredients, particularly herbs and spices, has a great application potential, and has already been implemented in many countries. Spice irradiation is performed to increase the hygienic quality and used as decontamination processes instead of fumigation methods. European Community approves irradiation processing as an effective residue-free alternative. The present paper evaluates the effect of ionizing radiation on sensorial properties of cinnamon (Laurus cinnamomum) and nut meg (Myristica fragans). The samples have been irradiated in multipurpose irradiator of {sup 60}Co in the doses: 0, 5, 10, 15, 20 e 25 kGy. (author)
2007-07-01
Predicted UV properties of very metal-poor starburst
We study the expected properties of starbursts in order to provide the point of reference for interpretation of high-z galaxy surveys and of very metal-poor galaxies. We concentrate mainly on the UV characteristics such as the ionizing spectra, the UV continuum, the Ly alpha and HeII 1640 A line and two-photon continuum emission. We use evolutionary synthesis models covering metallicities from Pop III to solar and a wide range of IMFs. We also combine the synthetic SEDs with the CLOUDY photoionization code for more accurate predictions of nebular emission, and to study possible departures from case B assumed in the synthesis models. The ionizing fluxes, UV continuum properties, and predicted Ly alpha and HeII 1640 A line strengths are presented for synthesis models covering a wider range of parameter space than our earlier calculations. Strong departures from case B predictions are obtained for Ly alpha and two-photon continuum at low ...
2010-01-01
Position sensitive and Bragg curve spectroscopy detector system
Energy Technology Data Exchange (ETDEWEB)
A heavy ion gas detector system consisting of a Bragg-curve spectroscopy ionization chamber for particle identification and a multiwire proportional chamber as position sensitive fast trigger device is described. The Bragg IC has been tested with several beams up to Z=36 to investigate some aspects of the BCS method. Results are reported on energy resolution and linearity, Z resolving power and mass sensitivity. The energy resolution is well below 1%. The Bragg-peak amplitude is fairly independent of the energy in a wide energy range and single elements are identified up to Z=38 with a resolving power Z/..delta..Zproportional50-80. Isotope identification by range measurement is limited by the straggling in the ionization process and the mass resolving power is M/..delta..Mproportional20-26 for S and Si isotopes. The MWPC allows subnanosecond time resolution and position identification along the in-plane coordinate within +-0.5 mm.
1984-08-01
Position sensitive and Bragg curve spectroscopy detector system
International Nuclear Information System (INIS)
A heavy ion gas detector system consisting of a Bragg-curve spectroscopy ionization chamber for particle identification and a multiwire proportional chamber as position sensitive fast trigger device is described. The Bragg IC has been tested with several beams up to Z=36 to investigate some aspects of the BCS method. Results are reported on energy resolution and linearity, Z resolving power and mass sensitivity. The energy resolution is well below 1%. The Bragg-peak amplitude is fairly independent of the energy in a wide energy range and single elements are identified up to Z=38 with a resolving power Z/#DELTA#Zproportional50-80. Isotope identification by range measurement is limited by the straggling in the ionization process and the mass resolving power is M/#DELTA#Mproportional20-26 for S and Si isotopes. The MWPC allows subnanosecond time resolution and position identification along the in-plane coordinate within +-0.5 mm. (orig.).
International Nuclear Information System (INIS)
In this paper, results on ozone production by atmospheric pulsed discharge, are reported. In the research, two types of ozonizer (Type I and Type II) have been used to investigate improvements of ozone concentration and production efficiency. The ozonizer has plane-to-plane metal electrodes structure, and pre-ionization electrodes are placed on the high voltage electrodes (Type I). In Type II, the surface of grounded electrode with 20 mm of width is covered partly by dielectric (thin rubber) with 11 mm of width, while the geometry of both metal electrodes is same to Type I. In the case of Type I, maximum concentration of about 100 ppm and maximum yield of 70 g/kWh were obtained at input power of 0.3 W. On the other hands, in the case of Type II, 800 ppm and 100 g/kWh were obtained at input power of 1.5 W. It was found that the ozone concentration and production yield were improved by using electrode covered by dielectric. (author)
2002-07-21
Multipass laser mass spectrometer with extreme jet-cooled pulsed gas
International Nuclear Information System (INIS)
We have developed a photon accumulated laser mass spectrometer that enables us to identify isomers of polychlorinated dibenzo-p-dioxin and polychlorinated dibenzofuran. This system is comprised of a high temperature (230 deg. C) pulsed gas injector (PGI), multimirror multipath system (MMS), and the conventional time-of-flight mass spectrometer. The PGI induces the formation of a choked supersonic jet gas pulse that cools down to a temperature to restrain fragmentation and reduces vibrational and rotational thermal noises. The results suggest that the excited lifetime numbers and fragment dynamics of these species change completely with jet cooling of molecules. The MMS enhances the soft ionization efficiency (by a factor of 1000 over a single path system) through photon accumulation by extending the irradiation duration (to about 40 ns) and volume, and it further minimizes fragmentation by carefully controlling the laser intensity distribution within the ...
2006-09-01
Isotope shift measurements at the {sup 242{ital f}}Am fission isomer
Energy Technology Data Exchange (ETDEWEB)
Isotope shift measurements have been performed for the {sup 242{ital f}}Am fission isomer with target production rates of only a few per second. The method is based on resonance ionization spectroscopy (RIS) in a buffer gas cell with radioactive decay detection of the ionization process (RADRIS). A relative isotope shift ratio X{sub {ital exp}}=IS{sup 242{ital f},241}/IS{sup 243,241}=41.7{plus_minus}0.9 has been measured for the 500.02 nm transition corresponding to a nuclear parameter A{sup 242{ital f},241}=(5.4{plus_minus}0.3) fm{sup 2}. A preliminary analysis of the quadrupole moment based on the deformed Fermi model of the nuclear charge distribution results in Q{sub 20}=35.9{plus_minus}1.1({sup +0.3}{sub {minus}0.7}) {sub model} eb. {copyright} 1995 {ital American} {ital Institute} {ital of} {ital Physics}
1995-04-01
Ion sources for initial use at the Holifield radioactive ion beam facility
Energy Technology Data Exchange (ETDEWEB)
The Holifield Radioactive Ion Beam Facility (HRIBF) now under construction at the Oak Ridge National Laboratory will use the 25-MV tandem accelerator for the acceleration of radioactive ion beams to energies appropriate for research in nuclear physics; negative ion beams are, therefore, required for injection into the tandem accelerator. Because charge exchange is an efficient means for converting initially positive ion beams to negative ion beams, both positive and negative ion sources are viable options for use at the facility; the choice of the type of ion source will depend on the overall efficiency for generating the radioactive species of interest. A high-temperature version of the CERN-ISOLDE positive ion source has been selected and a modified version of the source designed and fabricated for initial use at the HRIBF because of its low emittance, relatively high ionization efficiencies and species versatility, and because it has been engineered for remote ...
1994-12-31
Ion sources for initial use at the Holifield Radioactive Ion Beam Facility
Energy Technology Data Exchange (ETDEWEB)
The Holifield Radioactive Ion Beam Facility (HRIBF) now under construction at the Oak Ridge National Laboratory will use the 25-MV tandem accelerator for the acceleration of radioactive ion beams to energies appropriate for research in nuclear physics; negative ion beams are, therefore, required for injection into the tandem accelerator. Because charge exchange is an efficient means for converting initially positive ion beams to negative ion beams, both positive and negative ion sources are viable options for use at the facility; the choice of the type of ion source will depend on the overall efficiency for generating the radioactive species of interest. A high-temperature version of the CERN-ISOLDE positive ion source has been selected and a modified version of the source designed and fabricated for initial use at the HRIBF because of its low emittance, relatively high ionization efficiencies and species versatility, and because it has been engineered for remote ...
1994-05-01
Energy Technology Data Exchange (ETDEWEB)
The interference of hyperthermia and ionizing radiation, respectively, with the effects of capric (10:0), lauric (12:0), myristic (14:0), oleic (cis-18:1) and elaidic (trans-18:1) acids on the osmotic resistance of human erythrocytes was investigated. The results are summarized as follows: (A) not only at 37 degrees, but also at 42 and 47{degrees}C lauric acid (12:0) represents the minimum chain length for the biphasic behaviour of protecting against hypotonic hemolysis at a certain lower concentration range and hemolysis promotion at subsequent higher concentrations; (B) with increasing temperatures the protecting as well as the hemolytic effects occur at lower concentrations of the fatty acids; (C) the increase of temperature promotes the extent of hemolysis and reduces the extent of protection against hypotonic hemolysis; (D) Gamma-irradiation of erythrocytes selectively affects the concentration of oleic acid at which maximum protection against hypotonic ...
1990-04-01
Integral Field Unit Observations of NGC 4302: Kinematics of the Diffuse Ionized Gas Halo
We present moderate resolution spectroscopy of extraplanar diffuse ionized gas (EDIG) emission in the edge-on spiral galaxy NGC 4302. The spectra were obtained with the SparsePak integral field unit (IFU) at the WIYN Observatory. The spectra are used to construct position-velocity (PV) diagrams at several ranges of heights above the midplane. Azimuthal velocities are directly extracted from the PV diagrams using the envelope tracing method, and indicate an extremely steep dropoff in rotational velocity with increasing height, with magnitude ~30 km/s/kpc. We find evidence for a radial variation in the velocity gradient on the receding side. We have also performed artificial observations of galaxy models in an attempt to match the PV diagrams. The results of a statistical analysis also favor a gradient of ~30 km/s/kpc. We compare these results with an entirely ballistic model of disk-halo flow, and find a strong dichotomy between the observed kinematics and those ...
2007-01-01
International Nuclear Information System (INIS)
The inelastic energy losses for single collisions of Xe"+ ions with Xe targets have been measured for incident ion energies from 0.3 to 1.2 MeV and for scattering angles from 3"0 to 20"0. The energy losses were found to range from 1 to 11 keV with distinct steps at distances of closest approach of 0.22 and 0.12 A. By comparing these data with earlier ionization data by the same authors these steps are shown to be caused by M-shell excitation. Other excitations observed in the ionization data may be attributed to N-shell excitation. The distances of closest approach at which these excitations occur agree well with calculations by Eichler and Wille and co-workers, giving further evidence of the usefulness of Fano and Lichten's one-electron molecular model and these calculations.
IR double-resonance spectroscopy applied to the 4-aminophenol(H{sub 2}O){sub 1} cluster
Energy Technology Data Exchange (ETDEWEB)
The IR double-resonance techniques IR/R2PI (infrared/resonant 2-photon ionization), IR/PIRI (infrared-photo-induced Rydberg ionization) and IR-photodissociation spectroscopy are valuable tools to investigate structure, vibrations, and dynamical processes of neutral and ionic hydrogen-bonded clusters containing aromatic molecules. In this paper we report on the application of the IR double-resonance techniques to determine the NH and OH stretching vibrations of 4-aminophenol and 4-aminophenol(H{sub 2}O){sub 1}, both in the neutral (S{sub 0}) and ionic (D{sub 0}) ground state. All vibrational frequencies obtained for 4-aminophenol and the cluster are compared with the values obtained from ab initio and DFT calculations. In the S{sub 0} state, a trans-linear arrangement of 4-aminophenol(H{sub 2}O){sub 1} is obtained containing an O-H. O hydrogen bond. In the D{sub 0} state an overlay of two spectra can be observed resulting from the trans-linear ...
2001-03-01
Hyaluronic acid production by irradiated human synovial fibroblasts
International Nuclear Information System (INIS)
Radioactive particles as well as x irradiation from an external source has been used in the treatment of rheumatoid arthritis, osteoarthritis, and ankylosing spondylitis. In order to clarify effects of ionizing irradiation on synovial cells, radioactive gold ("1"9"8Au) and yttrium ("9"0Y) were added to fibroblast cultures derived from human synovial membranes. Other cultures were irradiated by a Picker x-ray machine. Fibroblast growth and hyaluronic acid production were measured. Radioactive gold and yttrium particles induced a significant increase of hyaluronic acid synthesis rate (pg/cell/day) and inhibited fibroblast growth. Fibroblasts continued to overproduce hyaluronic acid and to show growth inhibition 3 weeks after irradiation with radioactive gold. Hydrocortisone inhibited hyaluronic acid overproduction induced by radioactive gold. Overproduction of hyaluronic acid induced by the x-ray machine was inhibited by hydrocortisone, actinomycin-D, and ...
1977-01-01
International Nuclear Information System (INIS)
The genetically significant dose (GSD) is an index variable which exclusively allows to describe the genetic risk in the progeny of a population due to the application of ionizing radiation and radioactive substances in one part of this population. It may result in wrong interpretation of population exposure at increasing incidence of examinations in a population involving ionizing radiation and radioactive drugs at simultaneously increasing application of alternative methods in children and adolescents owing to the fact that it indicates a downward trend although somatic exposure of this population has increased. Therefore, it is recommended to state both the GSD and the level of somatic radiation exposure of the population taken from the individual sources for the comparison and assessment of radiation exposure from various sources in future. Although the somatically significant dose constitutes the suitable variable complementary to GSD in ...
1984-06-01
Detection system characteristics using sup 252 Cf ionization chambers
Energy Technology Data Exchange (ETDEWEB)
Because the number of neutrons and gamma rays and the energy spectrum of particles from spontaneous fission are well characterized for {sup 252}Cf, it can be used as a timed source of fission neutrons and gamma rays. The first such usage incorporated a {sup 252}Cf source into gas scintillators. This paper describes a timed source of neutrons and gamma rays made by depositing {sup 252}Cf on one electrode of a parallel plate ionization chamber that can then be used for determining detection-system characteristics. The emission time of neutrons from spontaneous fission has also been determined by recording the emission time of prompt gamma rays from a {sup 252}Cf source (not incorporated into a detector) adjacent to the surface of a solid or liquid scintillator. This well characterized source of neutrons can thus be used as a randomly pulsed source for a variety of applications. This paper illustrates the use of this type of source to determine the time resolution of ...
1990-01-01
Deposition of Cu film on SiO_2 using a partially ionized beam
International Nuclear Information System (INIS)
Ion bombardment during deposition can significantly modify the film properties. In the partially ionized beam deposition, ions derived from the depositing material, i.e., the self-ions, are used during deposition. Cu films were deposited on SiO_2 substrates at room temperature using 1% Cu self-ions with an energy ranging between 0--4 keV. We studied the microstructures of the Cu films using x-ray diffraction and transmission electron microscopy, measured the impurity level inside the films using secondary ion mass spectrometry, and performed the resistivity measurements using a four point probe. The results indicate that there is an optimum ion energy around 2 keV at which, the integrated x-ray intensity ratio I(111)/I(200) reaches its maximum value indicating a strong left-angle 111 right-angle texture, while the impurity concentration and resisitivity are minimum. The correlation between the structural, compositional and electrical properties are discussed in the ...
1990-01-01
Deposition of Cu film on SiO sub 2 using a partially ionized beam
Energy Technology Data Exchange (ETDEWEB)
Ion bombardment during deposition can significantly modify the film properties. In the partially ionized beam deposition, ions derived from the depositing material, i.e., the self-ions, are used during deposition. Cu films were deposited on SiO{sub 2} substrates at room temperature using 1% Cu self-ions with an energy ranging between 0--4 keV. We studied the microstructures of the Cu films using x-ray diffraction and transmission electron microscopy, measured the impurity level inside the films using secondary ion mass spectrometry, and performed the resistivity measurements using a four point probe. The results indicate that there is an optimum ion energy around 2 keV at which, the integrated x-ray intensity ratio {ital I}(111)/{ital I}(200) reaches its maximum value indicating a strong {l angle}111{r angle} texture, while the impurity concentration and resisitivity are minimum. The correlation between the structural, compositional and electrical properties are ...
1990-05-01
Deposition of Cu film on SiO sub 2 using a partially ionized beam
Ion bombardment during deposition can significantly modify the film properties. In the partially ionized beam deposition, ions derived from the depositing material, i.e., the self-ions, are used during deposition. Cu films were deposited on SiO{sub 2} substrates at room temperature using 1% Cu self-ions with an energy ranging between 0--4 keV. We studied the microstructures of the Cu films using x-ray diffraction and transmission electron microscopy, measured the impurity level inside the films using secondary ion mass spectrometry, and performed the resistivity measurements using a four point probe. The results indicate that there is an optimum ion energy around 2 keV at which, the integrated x-ray intensity ratio {ital I}(111)/{ital I}(200) reaches its maximum value indicating a strong {l angle}111{r angle} texture, while the impurity concentration and resisitivity are minimum. The correlation between the structural, compositional and electrical properties are ...
1990-05-01
Energy Technology Data Exchange (ETDEWEB)
A custom-built graphite-coated transmission ionization chamber is compared to the VacuDAP 2001 (VacuTec, Dresden, Germany), which has transparent conductive electrodes. A study was made of the dependence of response on x-ray tube potential for both types of chamber under identical conditions of exposure using over-table and under-table x-ray tubes. Since the calibration factor is the dose-area product of the radiation incident on the patient per chamber reading, it depends on the intrinsic response of the chamber as well as the effect of material in the beam between the x-ray tube and patient. Differences of about 20% were measured between the intrinsic and the over-table calibration factors and between the over-table and the under-table calibration factors for both chambers. The VacuDAP display is specifically calibrated for the over-table condition and would overstate the actual DAP in the under-table case. The intrinsic response of the graphite chamber is nearly ...
2000-03-01
International Nuclear Information System (INIS)
The dependences of kinetic energies and peak profiles of multicharged ions of I "q"+ (q = 2-3) and C"2"+ on the laser intensity have been studied in detail by time-of-flight mass spectrometry, those multicharged ions are produced by irradiation of methyl iodide cluster beam with a nanosecond 532 nm Nd-YAG laser. Our experiments show that the kinetic energies released of multicharged ions increase linearly with the laser intensity in the range of 3 x 10"9-2 x 10"1"1 W/cm"2. The peaks of multicharged ions are split to forward ions and backward ions, and the ratio of the backward ions to forward ions decreases exponentially with laser intensity. The decreasing of backward ions is probably due to Coulomb scattering by the heavier I"+ ions when they turn around through the laser focus point. The linear dependence of kinetic energy of multicharged ions on laser intensity is interpreted by the ionization mechanism, in which the laser induced inverse bremsstrahlung heating ...
2006-03-20
Can photo-ionization explain the decreasing fraction of X-ray obscured AGN with luminosity?
Chandra and XMM surveys show that the fraction of obscured AGN decreases rapidly with increasing luminosity. Although this is usually explained by assuming that the covering factor of the central engine is much smaller at luminous QSOs, the exact origin of this effect remains unknown. We perform toy simulations to test whether photo-ionisation of the obscuring screen in the presence of a strong radiation field can reproduce this effect. In particular, we create X-ray spectral simulations using a warm absorber model assuming a range of input column densities and ionization parameters. We fit instead the simulated spectra with a simple cold absorption power-law model that is the standard practice in X-ray surveys. We find that the fraction of absorbed AGN should fall with luminosity as $L^{-0.16\\pm0.03}$ in rough agreement with the observations. Furthermore, this apparent decrease in the obscuring material is consistent with the dependence of the FeK$\\alpha$ ...
2008-01-01
Animal models of ionizing-radiation damage. Technical report, 18 May 88-18 May 91
Energy Technology Data Exchange (ETDEWEB)
This report is a survey of the English language literature of radiation biology between 1947 and 1987, for the purpose of compiling a literature base on the effects of radiation on animals, which have yielded results that can expand our knowledge about similar radiation effects on human beings. Articles were sought that reported exposure of adult mammals to external sources of ionizing radiation, having endpoints that included effects on the brain, the spinal cord, and behavior of the gastrointestinal, endocrine, and cardiovascular systems and the hematopoietic and immune systems. Effects of interest were those that occurred within the first 12 months after exposure. The survey does not include articles reporting chronic or long term delayed effects of radiation unless they provided insight into mechanisms of morphological and/or functional derangement. Information presented in the report is divided into subtopics (i.e., Brain-Morphological Changes). The brief ...
1992-01-01
Energy Technology Data Exchange (ETDEWEB)
This report describes the work performed during FY 1995 by Pacific Northwest Laboratory in developing and optimizing analysis techniques for identifying organics present in Hanford waste tanks. The main focus was to provide a means for rapidly obtaining the most useful information concerning the organics present in tank waste, with minimal sample handling and with minimal waste generation. One major focus has been to optimize analytical methods for organic speciation. Select methods, such as atmospheric pressure chemical ionization mass spectrometry and matrix-assisted laser desorption/ionization mass spectrometry, were developed to increase the speciation capabilities, while minimizing sample handling. A capillary electrophoresis method was developed to improve separation capabilities while minimizing additional waste generation. In addition, considerable emphasis has been placed on developing a rapid screening tool, based on Raman and ...
1995-09-01
Additive effects common to radiation grafting and wood plastic composite formation
Energy Technology Data Exchange (ETDEWEB)
A range of additives has been developed for enhancing grafting yields in a variety of systems initiated by ionizing radiation. Cellulose has been adopted as the predominant naturally occurring model backbone polymer in these studies because of its structural relationship to wood which is the reference substrate for the work reported in the related second part of this paper concerning composites. Some experiments have been performed with the other major naturally occurring polymer, wool. For comparison purposes with synthetic materials, some studies have also been performed with polypropylene as trunk polymer. Styrene has been used as a predominant monomer in grafting with some experiments utilizing the acrulates like methyl methacrylate. The role of solvent in grafting has been evaluated. UV has been used as initiator to replace ionizing radiation for certain experiments. The additives used were mineral acids, lithium salts, multifunctional ...
1996-08-01
TIGER integral-field spectrography and HST/WFPC2 imaging of the E3 galaxy NGC 2974 are used to derive the kinematics of the stellar and ionized gas components in its central 500 pc. We derive a numerical two-integral distribution function from a MGE mass model using the HQ formalism. The TIGER as well as published long-slit stellar kinematics are well fitted with this self-consistent model, requiring neither the addition of a significant mass contribution from a hidden disc structure, nor the presence of a central dark mass. The data reveal the presence of a striking, highly contrasted, two-arm gaseous spiral structure within a radius of ~200 pc, corresponding to a total mass of 6.8x10^4 Msun of ionized gas. We use a deconvolved TIGER datacube to probe its kinematics at a resolution of about 0.35 arcsec. Strong departures from circular motions are observed, as well as high velocity dispersion values on the inner side of the arms. We interpret ...
2003-01-01
The General Spectral Modeling (GSM) code employs the quasi-static approximation, a standard, low-density methodology that assumes the ionization balance is separable from a determination of the excited-state populations that give rise to the spectra. GSM also allows for some states to be treated only as contributions to effective rates. While these two approximations are known to be valid at low densities, this work investigates using such methods to model high-density, non-LTE emission spectra and determines at what point the approximations break down by comparing to spectra produced by the LANL code ATOMIC which makes no such approximations. As both approximations are used by other astrophysical and low-density modeling codes, the results should be of broad interest. He-like K$\\alpha$ emission spectra are presented for Ni, Fe, and Ca, in order to gauge the effect of both approximations employed in GSM. This work confirms that at and above the temperature of ...
2007-01-01
Transverse glow discharges in supersonic air and methane flows
British Library Electronic Table of Contents (United Kingdom)
Transverse glow discharges in supersonic air and methane flows are studied both experimentally and theoretically. The experiments show that a diffuse volume discharge filling the whole cross section of the flow can easily be initiated in air, whereas a diffuse discharge in a methane flow shows a tendency to transition into a constricted mode. The electron transport coefficients (mobility and drift velocity) and the kinetic coefficients (such as collisional excitation rates of the vibrational levels of a methane molecule, as well as dissociation and ionization rates) are calculated by numerically solving the Boltzmann equation for the electron energy distribution function. The calculated coefficients are used to estimate the parameters of the plasma and the electric field in the positive co...
2006-01-01
The pharmacological activity of medical herbs after microbiological decontamination by irradiation
Energy Technology Data Exchange (ETDEWEB)
In the Institute of Nuclear Chemistry and Technology research on microbiological decontamination of medicinal herbs by irradiation has been carried out since 1996. It was shown that using ionizing radiation (a dose of 10 kGy) can obtain satisfactory results of microbiological decontamination of these products. The content of essential biologically active substances such as essential oils, flavonoids, glycosides, anthocyans, antra-compounds, poliphenoloacids, triterpene saponins, oleanosides and plants mucus did not change significantly after irradiation. Pharmacological activity of medicinal herbs has been found satisfactory after microbiological decontamination by irradiation.
2000-03-01
The advancement of stem cells in radiation medicine
International Nuclear Information System (INIS)
It may result in acute radiation syndrome after body is exposed to ionizing radiation. The one of long-term effects of irradiation injury is leukemia. The bone marrow cells (BMC) transplantation including stem cells is the only effective therapy for acute radiation syndrome patients. Recently, with the advancement of stem cell research that the stem cells have multipotential and can convert each other, it may supply the new stem source for the irradiation injury patients. At the same time with the further research of radioprotective reagents, the hematopoietic stem cells proliferation after irradiation injury is promoted
2003-02-01
Study of somatic radiation effects in environment
International Nuclear Information System (INIS)
A survey is presented of the consequences of the irradiation of the population with ionizing radiation. There is an increased incidence of leukemia in irradiated population groups. Among the inhabitants of Hiroshima and Nagasaki maximum death of leukemia was observed in the years 1951 to 1952. The results are summed up of the observation of carcinoma of the breast, lungs and bronchi, bones, and carcinoma of the thyroid. The effect of radiation on experimental animals is described. It was found that the scatter of the dependence of the incidence of various types of cancer on the dose equivalent apparently reflects differences in the biological mechanism of this incidence and that a proportional relationship cannot be expected between the primary damage of cells during irradiation and the actual manifestation of the disease. (E.S.).
Robotics and Automation Activities at the Savannah River Site: A Site Report for SUBWOG 39F
Energy Technology Data Exchange (ETDEWEB)
The Savannah River Site has successfully used robots, teleoperators, and remote video to reduce exposure to ionizing radiation, improve worker safety, and improve the quality of operations. Previous reports have described the use of mobile teleoperators in coping with a high level liquid waste spill, the removal of highly contaminated equipment, and the inspection of nuclear reactor vessels. This report will cover recent applications at the Savannah River, as well as systems which SRS has delivered to other DOE site customers.
1995-09-28
Results of a search for monopoles and tachyons in horizontal cosmic ray flux
International Nuclear Information System (INIS)
A search for monopoles and tachyons at ground level was carried out using an arrangement consisting of an ionization calorimeter and two hodoscope detectors. No clear evidence for these particles was obtained. The flux of monopoles with velocities beta approximately 0.01 is found to be less than 5.1 x 10 to the minus 13th power square centimeters s(-1) sr(-1) (95% cl.). The upper limit on the tachyon flux density is set as a 6 x 10 the minus 9th power particle/square centimeter event.
1985-08-01
Recycling of PTFE by means of ionizing rays
International Nuclear Information System (INIS)
By treatment with beta or gamma rays, PTFE waste is converted to high-grade PTFE fine powder. High-molecular weight PTFE is degraded to low-molecular weight PTFE. Due to this the density, the degree of crystallinity, and the melt flow index are increased, which enhances the brittleness of the material. Irradiation of PTFE thus facilitates milling and makes the material pourable and free-flowing. Milled PTFE fine powder, lie PTFE plastic, combines temperature resistance, weather fastness, and chemical stability with good slip behaviour and antiadhesive properties. Areas of application for fine powder include additives for plastics, printing inks, nonstick coatings, and antifriction lacquers. (orig.).
1994-01-01
Energy Technology Data Exchange (ETDEWEB)
Current information on the use of ionizing radiation for improving the storage of subtropical fruits like citrus, grapes, and avocados is reviewed. The feasibility of applying radiation either alone or in combination with other physical or chemical treatments for the control of postharvest fungal diseases is considered. Irradiation effects on the physiology of the fruits as related to respiration, ethylene evolution, changes in major chemical constituents, and quality are discussed. The recent trends in the possible use of irradiation as an alternative treatment to chemical fumigants for disinfestation of citrus and avocados and the prospects for the future application of irradiation for preservation of some of these fruits are outlined. 128 references.
1986-01-01
Radiation hardening of semiconductor parts
International Nuclear Information System (INIS)
This chapter is an overview of total-ionizing-dose and single-event hardening techniques and should be used as a guide to a range of research publications. It should be stressed that there is no clear and simple route to a radiation-tolerant silicon integrated circuit. What works for one fabrication process may not work for another, and there are many complex interactions within individual processes and designs. The authors have attempted to highlight the most important factors and those process changes which should bring improved hardness. The main point is that radiation-hardening as a procedure must be approached in a methodical fashion and with a good understanding of the response mechanisms involved.
Radiation hardening characterization of a VDMOS developed at CAS institute of microelectronics
International Nuclear Information System (INIS)
Total dose irradiation effects on a VDMOS developed at Institute of Microelectronics, CAS were investigated, particularly the electric parameter changes under different bias conditions. It was found that the breakdown voltage degradation by the irradiation depended mainly on the drain bias, whereas the threshold voltage degradation depended mainly on the gate bias. Thus, an innovative and effective method to domestic VDMOS total dose ionization characterization is that threshold voltage radiation hardening characterization should be tested on gate bias condition, and the breakdown voltage radiation hardening characterization, be tested on the drain bias. (authors)
2008-08-01
International Nuclear Information System (INIS)
The paper discusses some of the assumptions and methods employed for the control of ionizing radiation in the specifications for the civil construction of a planned free electron laser facility based on a 200 MeV, 5 mA superconducting recirculation electron accelerator. Consideration is given firstly to the way in which the underlying building configuration and siting aspects were optimized on the basis of the early assumptions of beam loss and radiation goals. The various design requirements for radiation protection are then considered, and how they were folded into an aesthetically pleasing and functional building. copyright 1997 American Institute of Physics.
1996-11-06
Preparation of wood-polymer composites by using ionizing radiation
International Nuclear Information System (INIS)
Radiation-initiated polymerization of styrene and acrylic acid in poplar wood were investigated for the preparation of wood-polymer composites. The direct irradiation method was applied to the monomer adsorbed poplar wood specimens. 8000 Ci "6"0Co source at a dose rate of about 0.4 Mrad/h was used. Furthermore the effects of carbon tetrachloride, methanol, dioxane and acrylonitrile on styrene polymerization were investigated and the reaction rates were calculated for each case. The influence of CCl_4 (10%) on acrylic acid polymerization in poplar wood was also determined. (author).
1982-05-01
Optimum plasma conditions for the efficient high-order harmonic generation in platinum plasma
International Nuclear Information System (INIS)
We studied the optimum plasma conditions that are required for efficient high-order harmonic generation in platinum plume. Harmonics up to the 49th order (?=16.32 nm) are analyzed under various conditions of laser-plasma interaction. Time-resolved ultraviolet spectra of platinum plasma at both optimum and nonoptimum conditions of harmonic generation are presented. We calculated the ionization states of the plasma, free electron density, and singly charged ion density at different prepulse intensities and compared them with experimental results.
2007-06-01
New focal plane detector system for the broad range spectrometer
Energy Technology Data Exchange (ETDEWEB)
A focal plane detector system consisting of a vertical drift chamber, parallel plate avalanche counters, and an ionization chamber with segmented anodes has been installed in the Broad Range Spectrometer at the Holifield Facility at Oak Ridge. The system, which has been designed for use with light-heavy ions with energies ranging from 10 to 25 MeV/amu, has a position resolution of approx. 0.1 mm, a scattering angle resolution of approx. 3 mrad, and a mass resolution of approx. 1/60.
1984-01-01
Microscopic model for the higher-order nonlinearity in optical filaments
Using an exactly soluble one-dimensional atomic model we explore the idea that the recently observed high-order nonlinearity in optical filaments is due to virtual transitions involving the continuum states. We show that the model's behavior is qualitatively comparable with the experimentally observed cross-over from self-focusing to de-focusing at high intensities, and only occurs at intensities which result in significant ionization. Based on these observations, we conjecture that this continuum electron nonlinear refraction exhibits strong memory effects, and most importantly, the change of its sign is effectively masked by the de-focusing due to free electrons.
2010-01-01
Mechanical variations of diffused plasma parameters in a double plasma device
International Nuclear Information System (INIS)
Experimentally it is shown that a movable grounded metallic plate placed inside a multi-dipole magnetic cage can vary the diffused plasma parameters such as density, plasma potential and electron temperature. Plasma is solely produced in the source section of a double plasma device by a dc hot filament discharge and a low-density plasma is produced in the target section by local ionization of neutral gas by the high energetic electrons coming from the source section. A grounded movable stainless steel plate is inserted in the target section of the device. The floating potential of the plate also changes depending on the position of the plate inside the magnetic cage.
2007-06-21
Ionization and fragmentation of DNA, RNA bases induced by proton impact
Energy Technology Data Exchange (ETDEWEB)
We present recent results obtained in the Toulouse's group that deal with proton to base and nucleoside interactions. We stress the weakness of the sugar part in the nucleoside, i.e. the uridine molecule under scrutiny. Since some parts of the fragmentation spectrum correspond to the fragmentation of a 'pure' uracil molecule, i.e. the RNA base, an 'additivity rule' seems to prevail for the nucleoside, something that still has to be confirmed. Moreover, some results that deal with the secondary electronic emission from uracil are also displayed.
2008-02-01
International trends in radiation protection
International Nuclear Information System (INIS)
The great uranium debate throughout the industrialised world has intensified awareness of the biological hazards from ionizing radiation. It is therefore appropriate to use this awareness to draw attention to medical X-Radiation which today represents the most significant risk to future generations. There is ample legislation to control proliferation of nuclear development but in diagnostic radiology proliferation is unlimited; most international surveys indicate an unchecked annual growth rate of 15%. The article looks at risk hypotheses, dose measurements and the responsibilities of practising radiographers, and also reviews the international situation as reported at the 1977 world congress of radiation protection.
International Nuclear Information System (INIS)
The additional error in measurement of the thickness of Kh18N10T steel for possible changes in composition with an energy of the photons of ionizing radiation of 10-80 keV was evaluated. The desirability of use of a type REIS-I x-ray emitter in measurement of the thickness of steel up to 1 mm is shown. The instrument provides measurement of the thickness of steel in the 0.1-1.0 mm range with a reproducibility of the results with an error not exceeding 0.5-1.0%. The measurement error with corrugations characteristic of bellows does not exceed 5%.
International Nuclear Information System (INIS)
This article considers the application of simple trial wave functions to calculate the ground state energy of a hydrogen-like center near the interface of two media. Calculations have been performed taking into account the image potential. It has been shown that different kinds of wave functions are optimal at different distances from the interface. A relatively simple wave function has been suggested to represent main features of the dependence of the ground state energy on the distance to the interface. (authors)
2009-01-01
International Nuclear Information System (INIS)
The document represents a guide for the external decontamination of persons accidentally radio contaminated due to the use, production or transport of radioactive materials. The general conditions, from the medical point of view, to be kept in mind, in the event of accidental overexposures as decontamination treatment and the handling of samples are detailed throughout report. The external contamination without injury in skin or with wound its considered. The distribution of measures and responsibilities for the therapy of the irradiated patients with radioactive materials are enumerated. The preparations of decontaminate solutions are detailed in this work. Moreover, forms for the reception, physical evaluation of the patient and external contamination are presented. (author)
Energy Technology Data Exchange (ETDEWEB)
This digest paper presents the theoretical project of a fission engine for space ship as imagined by Y. Ronen from the Ben-Gourion Univ. (Israel). In this engine, the combustion chamber is covered with metastable {sup 242}Am thin sheets. The fission reaction is triggered with a bombardment of neutrons and the fission fragments ionize a gas (hydrogen, for instance) which is overheated and ejected through the engine nozzle. (J.S.)
2002-01-01
Free radicals and their transformations in irradiated proteins
International Nuclear Information System (INIS)
Experimental investigation data are systematized of free radical states and processes in irradiated proteins. The investigation is performed by the radiospectral methods. Results are discussed in detail of the study of free radicals electronic structure of amino acids, peptides and proteins formed by the action of ionizing radiation. The specificity is stressed of the study of monocrystalls of these compounds by the method of electronic paramagnetic resonance. The nature is also studied of primary centres formed under the effect of radiation on biologically important compounds and their subsequent reactions in solid and liquid solutions. Ion-radical states of different functional groups of the protein molecule are studied. Prospects of the study and the role of anion-radicals in biological processes are discusses.
Formation of charge and energy distribution of heavy ions in substance according to diffusion model
International Nuclear Information System (INIS)
The formation of the ions charge and energy distributions of the ions slowed down or randomly changing their charge in the collisions with the medium particles are studied. The effect of the ions dispersion by the charge on the Bragg curve form is investigated. The proposed diffusion approximation for the heavy ions kinetic equation makes it possible to determine simply the parameters of the ions distribution by charge and energy on the whole way of the ions motion. The relation between the ions charge distribution characteristics and the cross sections of the ionization-recombination processes is indicated. The ions distributions, calculated in the proposed analytical model, are compared with the results of the numerical calculations. Good agreement between the analytical, numerical and experimental results is obtained
2003-11-01
Energy Levels of Phosphorus, P I through P XV
Energy level data are given for the atom and all positive ions of phosphorus (Z = 15). These data have been critically compiled, mainly from published and unpublished material on measurements and analyses of the optical spectra. We have derived or recalculated the levels for a number of the ions. In addition to the level values in cm/sup -1/ and the parity, the J value and the configuration and term assignments are listed if known. Leading percentages from the calculated eigenvectors are tabulated or quoted wherever available. Ionization energies are given for all spectra.
1985-07-01
Emittance characteristics of negative ion beams generated by the sputter technique
Energy Technology Data Exchange (ETDEWEB)
Average emittance data for ion beams extracted from cesium-sputter negative ion sources equipped with spherical, ellipsoidal, and cylindrical geometry cesium-surface ionizers are presented. The attributes of the respective source geometries are described in terms of their cesium ion optical properties. The results of recent measurement of the emittances of momentum-analyzed beams extracted from the ellipsoidal geometry source are also presented. These measurements indicate the presence of a species-dependent effect. The effect is believed to be attributable to differences in the energy spreads of the respective negative ion beams introduced by the sputter generation process.
1990-01-01
Emittance characteristics of negative ion beams generated by the sputter technique
Energy Technology Data Exchange (ETDEWEB)
Average emittance data for ion beams extracted from cesium-sputter negative ion sources equipped with spherical, ellipsoidal, and cylindrical geometry cesium-surface ionizers are presented. The attributes of the respective source geometries are described in terms of their cesium ion optical properties. The results of recent measurement of the emittances of momentum-analyzed beams extracted from the ellipsoidal geometry source are also presented. These measurements indicate the presence of a species-dependent effect. The effect is believed to be attributable to differences in the energy spreads of the respective negative ion beams introduced by the sputter generation process. 11 refs., 8 figs.
1989-01-01
International Nuclear Information System (INIS)
Mass spectrometry was instrumental in the discovery of the fullerenes and the characterization of their special structure (truncated icosahedron). High resolution and high sensitivity mass spectrometry in combination with a crossed molecular beam/electron beam ion source is used here to study a further, very unique property of singly and multiply charged fullerene ions (up to Z=7), i.e. their strong resilience towards decomposition via sequential C_2 evaporation and via Coulomb explosion, respectively. (author).
1994-03-20
Electron Beam and Gamma Radiolysis of Solid-State Metoclopramide
British Library Electronic Table of Contents (United Kingdom)
Purpose Study the radiolysis of solid-state metoclopramide hydrochloride at various absorbed doses. Elucidate the structure of the degradation products to gain information on the radiolysis mechanisms. Methods Solid-state metoclopramide samples were irradiated at several doses with gamma rays and high-energy electrons to evaluate the influence of the dose rate. High-performance liquid chromatography with a diode array detector was used to measure the chemical potency as a function of the absorbed dose and to quantify the degradation products. The characterization of degradation products was performed by liquid chromatography/atmospheric pressure chemical ionization/tandem mass spectrometry. Results The degradation of solid-state metoclopramide after irradiation was negligible. No qualitati...
2006-01-01
Energy Technology Data Exchange (ETDEWEB)
A study is made of plant sensitivity to mutagens during the processing of seeds. An examination is made of problems concerned with modification mutability, the nature of plant restoration following irradiation. Particular attention is given to mutation changes. A presentation is made of several features of mutant changes initially selected by separate indicators. An examination is made of the possible study of mutant indicator genetics. General data on the forms and varieties produced by the mutagenesis method are given. The book is designed for breeding specialists and geneticists engaged in the study of mutagenesis. 439 references, 27 figures, 66 table.
1981-01-01
ESR spectra of radicals of gamma-irradiated wood and cellulose
International Nuclear Information System (INIS)
Spectra of e.p.r. radicals in cellulose and timber gamma-irradiated at 77 and 300 K have been measured. Radiation yields and the kinetics of radicals accumulation have been studied. The effect of ionizing radiation on cellulose is the appearance of radicals resulting from rupture of C-H bonds in positions 1 and 4. Timber, additionally, forms ''lignin'' radicals. A mechanism of cellulose and timber radiolysis is suggested. ''Lignin''-type compounds present in timber protect polysaccharides from radiation-induced destruction.
Determination of the cell and mucous distribution in the airways of the lung
International Nuclear Information System (INIS)
Models of the human airways have played a major role in evaluating the health effects of inhaled radionuclides. While models such as those of Weibel (1963) provide data necessary for characterizing deposition of aerosol, they have not characterized the cells at risks in the airspaces. Given the advancements in techniques and study of cell cultures exposed to ionizing radiation there is a need to extrapolate between the simple structures of cell culture systems and the complex architecture of the human airways. The preliminary data in this paper provide a complete characterization of the size and number of cells in the airways and represents a significant advance in our study of the health consequences of exposure to inhaled radionuclides. 26 refs., 2 figs., 4 tabs.
1991-01-01
International Nuclear Information System (INIS)
Remote-controlled handling systems are required for work to be done in the decommissioning and dismantling of nuclear facilities. These systems are equipped with electronic devices suitable for use in working environments affected by ionizing radiation. The publication explains the step-wise progress achieved for improving the radiation resistance of electronic devices with the example of a four-quadrant controlling device for the motors of a manipulator. The radiation resistance of the device could be enhanced to radiation energies of 5.500 Gy. This means that a manipulator vehicle equipped with this controlling device can take up to approx. 15 kGy all in all, taking into account its own shielding properties. (DG).
Characterization of nuclear fuels by ICP mass-spectrometric techniques
British Library Electronic Table of Contents (United Kingdom)
Isotopic analyses of radioactive materials such as irradiated nuclear fuel are of major importance for the optimization of the nuclear fuel cycle and for safeguard aspects. Among the mass-spectrometric techniques available, inductively coupled plasma mass spectrometry (ICP-MS) and thermal ionization mass spectrometry are the most frequently applied methods for nuclear applications. Because of the low detection limits, the ability to analyze the isotopic composition of the elements and the applicability of the techniques for measuring stable as well as radioactive nuclides with similar sensitivity, both mass-spectrometric techniques are an excellent amendment to classical radioactivity counting methods. The paper describes selected applications of multicollector ICP-MS in combination with c...
2008-01-01
Energy Technology Data Exchange (ETDEWEB)
Long-Range Alpha Detector (LRAD) systems are designed to monitor alpha contamination by measuring the number of ions in the air. Alpha particles are a form of ionizing radiation and a typical 5-MeV alpha particle will create about 150,000 ion pairs in air. Field tests at various DOE sites have shown that LRAD Surface Soil Monitors (SSM), Sample Monitors, and Object Monitors are faster and more sensitive than traditional alpha detectors for measuring alpha contamination. This paper discusses the various applications of LRAD technology to low-level radioactive waste management.
1993-12-01
Application of the digital waveform analysis to Bragg curve spectrometer
International Nuclear Information System (INIS)
Energy and angular double-differential cross-section (DDX) data of fragment production reactions by neutrons or protons are very scarce due to experimental difficulties of fragment detection. We adopted a Bragg curve spectrometer (BCS), which is a gridded-ionization chamber that can identify fragments on the basis of the Bragg peak value. We have been developing the BCS for neutron and proton-induced reactions applying the digital waveform analysis technique to obtain better ability of particle discrimination than the analog electronic circuit. (T. Tanaka)
2004-11-01
A multiple sampling proportional counter for particle identification of relativistic heavy ions
Energy Technology Data Exchange (ETDEWEB)
A multiple sampling dE/dx counter using a multiwire proportional chamber equipped with catbode pads was constructed for the multiple detection of dE/dx values along a particle trajectory. For low-energy particles this counter was proved to be useful as a Bragg-curve detector. At relativistic energies around E=14.6 GeV/nucleon good particle identification was obtained by cathode pad signals as well as anode signals for the range of projectile fragments from Z=1 (minimum ionization) up to a beam charge of Z=14. (orig.).
1990-11-15
M-shell x-ray production by 0.6--4.0-MeV protons in ten elements from hafnium to thorium
International Nuclear Information System (INIS)
M-shell x-ray production cross sections for selected heavy elements, namely, _7_2Hf, _7_3Ta, _7_4W, _7_5Re, _7_6Os, _7_7Ir, _7_8Pt, _7_9Au, _8_3Bi, and _9_0Th, were measured for protons of energy 0.6--4.0 MeV. The experimental results are compared with the predictions of the first Born and semiclassical approximations for M-shell ionization; these data are also compared with the theory that accounts for the projectile's energy loss and Coulomb deflection as well as for the target's M-shell electron perturbed stationary state and relativistic nature (ECPSSR). Generally, fair agreement between the data and the ECPSSR theory is found. Some systematical discrepancies observed for the lightest elements (Hf, Ta, and W) are explained as possible ambiguities in the M-shell Coster-Kronig factors and fluorescence yields, which were used to convert theoretical M-subshell ionization cross sections to the total M-x-ray production cross sections. The ...
Ionizing radiation-induced mutation of human cells with different DNA repair capacities
Energy Technology Data Exchange (ETDEWEB)
We have observed significant differences in the response to ionizing radiation of two closely related human cell lines, and now compare the effects on these lines of both low and intermediate LET radiation. Compared to TK6, WTK1 has an enhanced X-ray survival, and is also more resistant to cell killing by {alpha}-particles. The hprt locus is more mutable in WTK1 than in TK6 by both X-rays and {alpha}-particles. WTK1 is also more mutable by {alpha}-particles than by X-rays at the hprt locus. X-ray-induced mutation at the heterozygous tk locus in WTK1 is about 25 fold higher than in TK6, while {alpha}-particle-induced mutation is nearly 50 fold higher at this locus. Also, the slowly growing tk- mutants, which comprise the majority of spontaneous and X-ray-induced tk- mutants of TK6, were not induced significantly by {alpha}-particles. Previously, we showed that TK6 has a reduced capacity for recombination compared with WTK1, and therefore, these results indicate that ...
1994-12-31
International Nuclear Information System (INIS)
When exposure-calibrated ionization chambers are used to calibrate megavoltage X-ray and electron beam therapy machines, the calibration factor can be divided into a chamber-dependent and a chamber-independent component. Until recently, only the chamber-independent part, which has been derived theoretically, has been used; the chamber-dependent component has been ignored. Recent experimental and theoretical considerations, however, have indicated that the dependent component must be taken into account and can affect the calibration by as much as 4%. The calibration can change due to (i) the thickness of the chamber wall, (ii) the chamber wall composition, i.e. whether the chamber is constructed of air-equivalent material, or tissue- or water-equivalent material, and (iii) the size of the chamber changing the displacement factor. Theoretical and experimental evidence indicates that the third factor varies from approximately 4.5% for "6"0Co #gamma#-rays to 0.5% for ...
High frequency breakdown voltage
Energy Technology Data Exchange (ETDEWEB)
This report contains information about the effect of frequency on the breakdown voltage of an air gap at standard pressure and temperature, 76 mm Hg and O{degrees}C, respectively. The frequencies of interest are 47 MHz and 60 MHz. Additionally, the breakdown in vacuum is briefly considered. The breakdown mechanism is explained on the basis of collision and ionization. The presence of the positive ions produced by ionization enhances the field in the gap, and thus determines the breakdown. When a low-frequency voltage is applied across the gap, the breakdown mechanism is the same as that caused by the DC or static voltage. However, when the frequency exceeds the first critical value f{sub c}, the positive ions are trapped in the gap, increasing the field considerably. This makes the breakdown occur earlier; in other words, the breakdown voltage is lowered. As the frequency increases two decades or more, the second critical frequency, f{sub ce}, ...
1992-03-01
Energy Technology Data Exchange (ETDEWEB)
Energy and angular double differential cross-section data of fragments by tens of MeV neutron or proton are important to evaluate dosimetry and radiation effect in devices or instruments, since fragments cause a large local ionization. Up to now, experimental data of the fragment production are very scarce due to experimental difficulties of fragment detection. A bragg curve spectrometer (BCS) for fragment measurement is a gridded-ionization chamber that identify fragments on the basis of the difference of Bragg peak value. The BCS was fabricated to adopt for fragment measurement in neutron-induced reactions and tested with a charged-particle beam and then applied to a neutron field successfully. The structure of BCS is a cylindrical gridded ionization chamber, and filled with a Ar + 10% CH{sub 4} gas at a pressure of 2.7 x 10{sup 4} Pa. To confirm the performance of BCS, the following tests were performed: 1) the ...
2002-09-01
Microfabricated polyester conical microwells for cell culture applications.
Over the past few years there has been a great deal of interest in reducing experimental systems to a lab-on-a-chip scale. There has been particular interest in conducting high-throughput screening studies using microscale devices, for example in stem cell research. Microwells have emerged as the structure of choice for such tests. Most manufacturing approaches for microwell fabrication are based on photolithography, soft lithography, and etching. However, some of these approaches require extensive equipment, lengthy fabrication process, and modifications to the existing microwell patterns are costly. Here we show a convenient, fast, and low-cost method for fabricating microwells for cell culture applications by laser ablation of a polyester film coated with silicone glue. Microwell diameter was controlled by adjusting the laser power and speed, and the well depth by stacking several layers of film. By using this setup, a device containing hundreds of microwells ...
2011-05-26
Energy Technology Data Exchange (ETDEWEB)
In order to fabricate high temperature superconducting tapes for power applications, the authors have analyzed different buffer layer architectures grown on textured Ni substrates suitable for YBCO deposition. Due to its optimal lattice matching the studied structures present as top layer a CeO{sub 2} film. The deposition of CeO{sub 2} on Ni substrates was performed by pulsed laser ablation and by e-beam evaporation at different temperatures. The films obtained by the two deposition techniques have not optimal structural properties, having a polycrystalline component. The misorientation of CeO{sub 2} is probably due to the formation of NiO at the interface between the film and the substrate during the deposition process even if no oxygen is introduced. In order to prevent Ni oxidation an intermediate 2000 {angstrom} Pd thick film was deposited by e-beam. Furthermore, the lattice mismatch between Pd and CeO{sub 2} is smaller than that between Ni and CeO{sub 2}. The ...
1999-04-20
Energy Technology Data Exchange (ETDEWEB)
The Siberian Altai covers about 70% of the area of all south Siberian glaciers, which provide fresh water to the upper tributaries of the Ob and Yenisey rivers. The observed air temperature has increased by 1.2 deg. C over northern Eurasia during the last 120 years, affecting the degradation of the Siberian Altai glaciers. In this study, we estimated glacier area changes in the Aktru River basin (44.8 km{sup 2}), located in the central Altai mountains. We used the 1952, 1966, 1975 and 2006 remote sensed images with 0.6-3.0 m spatial resolution (aerial photographs, Corona and PRISM satellite images) and differential GPS (DGPS) data. From 1952 to 2006, the total glacier area in the Aktru basin shrank by 7.2% (1.2 km{sup 2}). During the last three decades, the rate of glacier area loss increased by a factor of 1.8, thus resembling trends in other mountain systems of Eurasia (Alps, Tien Shan). The glacier area changes were caused mainly by increase of summer air temperature by 1.03 deg. C ...
2007-10-15
International Nuclear Information System (INIS)
The Siberian Altai covers about 70% of the area of all south Siberian glaciers, which provide fresh water to the upper tributaries of the Ob and Yenisey rivers. The observed air temperature has increased by 1.2 deg. C over northern Eurasia during the last 120 years, affecting the degradation of the Siberian Altai glaciers. In this study, we estimated glacier area changes in the Aktru River basin (44.8 km"2), located in the central Altai mountains. We used the 1952, 1966, 1975 and 2006 remote sensed images with 0.6-3.0 m spatial resolution (aerial photographs, Corona and PRISM satellite images) and differential GPS (DGPS) data. From 1952 to 2006, the total glacier area in the Aktru basin shrank by 7.2% (1.2 km"2). During the last three decades, the rate of glacier area loss increased by a factor of 1.8, thus resembling trends in other mountain systems of Eurasia (Alps, Tien Shan). The glacier area changes were caused mainly by increase of summer air temperature by 1.03 deg. C (from 1951 ...
Experience and recent developments in nuclear forensics at the Institute of Isotopes
International Nuclear Information System (INIS)
Full text: Based on experience with nuclear material confiscated in Hungary from illicit trafficking activities in the nineties it has been decided that traditional gamma-spectrometry should be complemented by destructive analytical techniques. The 17/1996 (I. 31.) Korm. Governmental Decree delegated the identification, categorization and characterization tasks to the Institute of Isotopes, Budapest. Routine gamma-spectrometric methods have been further developed aiming at the i) age (production date) determination of seized samples and complete (nondismountable) uranium-bearing items (such as fresh fuel bundles and fission chambers) by HRGS technique, ii) improvement of measurement accuracy and reliability. Starting in 2005 mass spectrometry (ICP-SFMS) and scanning electron microscopy have been implemented to characterize nuclear samples in more detail and to analyze environmental samples both for isotopic and elemental composition focusing on long-lived radioactive isotopes including ...
Energy Conversion and Storage Program: 1992 Annual report
Energy Technology Data Exchange (ETDEWEB)
This report is the 1992 annual progress report for the Energy Conversion and Storage Program, a part of the Energy and Environment Division of the Lawrence Berkeley Laboratory. Work described falls into three broad areas: electrochemistry; chemical applications; and materials applications. The Energy Conversion and Storage Program applies principles of chemistry and materials science to solve problems in several areas: (1) production of new synthetic fuels, (2) development of high-performance rechargeable batteries and fuel cells, (3) development of advanced thermochemical processes for energy conversion, (4) characterization of complex chemical processes and chemical species, and (5) study and application of novel materials for energy conversion and transmission. Projects focus on transport-process principles, chemical kinetics, thermodynamics, separation processes, organic and physical chemistry, novel materials, and advanced methods of analysis. Electrochemistry research aims to ...
1993-06-01
Energy Conversion and Storage Program. 1990 annual report
Energy Technology Data Exchange (ETDEWEB)
The Energy Conversion and Storage Program applies chemistry and materials science principles to solve problems in (1) production of new synthetic fuels, (2) development of high-performance rechargeable batteries and fuel cells, (3) development of advanced thermochemical processes for energy conversion, (4) characterization of complex chemical processes, and (5) application of novel materials for energy conversion and transmission. Projects focus on transport-process principles, chemical kinetics, thermodynamics, separation processes, organic and physical chemistry, novel materials, and advanced methods of analysis. Electrochemistry research aims to develop advanced power systems for electric vehicle and stationary energy storage applications. Topics include identification of new electrochemical couples for advanced rechargeable batteries, improvements in battery and fuel-cell materials, and the establishment of engineering principles applicable to electrochemical energy storage and ...
1992-03-01
Energy Conversion and Storage Program
Energy Technology Data Exchange (ETDEWEB)
The Energy Conversion and Storage Program applies chemistry and materials science principles to solve problems in (1) production of new synthetic fuels, (2) development of high-performance rechargeable batteries and fuel cells, (3) development of advanced thermochemical processes for energy conversion, (4) characterization of complex chemical processes, and (5) application of novel materials for energy conversion and transmission. Projects focus on transport-process principles, chemical kinetics, thermodynamics, separation processes, organic and physical chemistry, novel materials, and advanced methods of analysis. Electrochemistry research aims to develop advanced power systems for electric vehicle and stationary energy storage applications. Topics include identification of new electrochemical couples for advanced rechargeable batteries, improvements in battery and fuel-cell materials, and the establishment of engineering principles applicable to electrochemical energy storage and ...
1992-03-01
Energy Technology Data Exchange (ETDEWEB)
Laser-Induced Breakdown Spectroscopy was selected by NASA as part of the ChemCam instrument package for the Mars Science Laboratory rover to be launched in 2009. ChemCam's Laser-Induced Breakdown Spectroscopy instrument will ablate surface coatings from materials and measure the elemental composition of underlying rocks and soils at distances from 1 up to 10 m. The purpose of our studies is to develop an analytical methodology enabling identification and quantitative analysis of these geological materials in the context of the ChemCam's Laser-Induced Breakdown Spectroscopy instrument performance. The study presented here focuses on several terrestrial rock samples which were analyzed by Laser-Induced Breakdown Spectroscopy at an intermediate stand-off distance (3 m) and in an atmosphere similar to the Martian one (9 mbar CO{sub 2}). The experimental results highlight the matrix effects and the measurement inaccuracies due to the noise accumulated ...
2006-03-15
International Nuclear Information System (INIS)
Laser-Induced Breakdown Spectroscopy was selected by NASA as part of the ChemCam instrument package for the Mars Science Laboratory rover to be launched in 2009. ChemCam's Laser-Induced Breakdown Spectroscopy instrument will ablate surface coatings from materials and measure the elemental composition of underlying rocks and soils at distances from 1 up to 10 m. The purpose of our studies is to develop an analytical methodology enabling identification and quantitative analysis of these geological materials in the context of the ChemCam's Laser-Induced Breakdown Spectroscopy instrument performance. The study presented here focuses on several terrestrial rock samples which were analyzed by Laser-Induced Breakdown Spectroscopy at an intermediate stand-off distance (3 m) and in an atmosphere similar to the Martian one (9 mbar CO2). The experimental results highlight the matrix effects and the measurement inaccuracies due to the noise accumulated when low signals are ...
2006-03-01
Energy Technology Data Exchange (ETDEWEB)
We report on the single and double multiphoton ionization of ground state Sr atoms observed in an atomic beam experiment with laser pulses of {approx}5 ns duration, maximum intensity {approx}4 x 10{sup 11} W cm{sup -2} and within the 710-740 nm wavelength range. The Sr{sup +} spectrum consists of two strong lines originating from three-photon resonant four-photon ionization of bound states, a number of weak autoionizing resonances and a broad line due to four-photon excitation of the doubly excited 5p{sup 2} {sup 1}S{sub 0} state. The latter, along with a strong, broad and structured spectral feature, is also evident in the wavelength dependence of the doubly charged Sr{sup 2+} ion. A weakly evident but reproducible inflection point ('knee' structure) appears in the intensity dependence of the Sr{sup 2+} yield at the location of the 5p{sup 2} {sup 1}S{sub 0} resonance. A complementary fluorescence experiment revealed the ...
2008-02-28
Irradiation as an alternative post harvest treatment
International Nuclear Information System (INIS)
This current world population has significantly added to the pressures placed upon our finite resources and our resulting ability to feed ourselves. In order to cope with current and future demands, the two established lines of action, that is, reduced population growth and expansion of agricultural production, must be supplemented with the parallel activity of reducing food losses during and after harvest. For developing countries in particular, enormous post-harvest losses result from spillage, contamination, pests and physiological deterioration during storage. Studies in these countries indicate that post-harvest losses are enormous and amount to tens of millions of tons per year valued at billions of dollars. Programs to reduce post-harvest losses, if applied properly, can result in realistic yield increases between 10 and 30%, which can be directly converted into increased consumption for humans. Post-harvest losses vary greatly and are a function of the crop variety, pest ...
1997-10-27
[Reactive collisions of high-temperature systems]. [Technical progress report 1990
Energy Technology Data Exchange (ETDEWEB)
The object of this research is to study reactivity at superthermal collision energies using a fast neutral beam that is generated by photodetachment. Systems scheduled for initial study include basic oxygen-hydrogen reactions. Unfortunately, we can not yet report realization of this goal, but during this funding period we have made advances that are anticipated to lead to successful measurements during the next year. The parameters described below refer to the model system O + H{sub 2} {yields} OH + H. The basic design involves the collision of fast neutrals, created by photodetachment of the corresponding negative molecular ion, with a stable reactant gas in a collision cell. Products are detected by ionization and mass analysis. We are equipped to study rotational effects on reactivity by comparing results for rotational levels J = 0 and 1 of H{sub 2}. Highlights during the funding period are given in this report.
1990-12-31
[Destruction of radioactive particles by strains of Cladosporium cladosporoides (FRES.) de Vries].
Reactions on the ionizing radiation of 14 Cladosporium cladosporioides strains were studied. Only 5 of them displayed radiotropizm. The ability of C. cladosporioides strains 4 and 5 with positive radiotropizm and museum C. cladosporioides strain 396 and its alb-mutant SM without positive radiotropizm to destruct radioactive particles of Chernobyl and explosion origin was studied. Two ways of radioactive particles destruction by C. cladosporioides were established, one of them is a direct way by fungal overgrowth of hot particles and the second one an indirect way only by fungal metabolites. Mycelium of the studied C. cladosporioides strains sorbed radionuclides from radioactive particles during cultivation on the liquid and agarized media. No certain inclinations of the individual strains to accumulation of radionuclides 137Cs or 152Eu were ascertained. PMID:12664550
X-ray exposure in the teaching of science at junior and senior high schools
Energy Technology Data Exchange (ETDEWEB)
A significant amount of X-rays were detected as a leakage from some of the Crooke`s tubes which were used in the teaching of science at junior and senior high schools in Japan. We measured the leaked dose of X-rays from the Crooke`s tubes with ionizing chambers, film badges and TLDs. The maximum leaked dose at 5cm distance from those tubes was estimated 143mSv/h. The effective energy of leaked X-rays was 19.3keV. The maximum dose of students exposed during the teaching of science were estimated 0.15mSv per experiment, which exceeded the value recommended in the ICRP publication 36. (author)
1995-10-01
Use of robotics for radioactive waste shipping and receiving
International Nuclear Information System (INIS)
Radioactive waste shipping and receiving facilities presently planned for commercial and defence high level nuclear waste will handle waste packages at frequencies far in excess of those in common practice today. If current limits for radiation levels at the cask surface and current handling methods are used, high cumulative personnel exposure to ionizing radiation is projected to occur. To reduce these exposure levels, alternate handling methods are being developed and demonstrated. The production nature of cask receiving operations suggests commercial robotics be incorporated into a remote handling system to reduce predicted worker exposure to acceptable levels while maintaining or increasing throughput. The first phase of cask handling system development culminated in a proof-of-principle test demonstrating the feasibility of performing cask receiving and unloading operations in a remote and partially automated manner. (author).
1986-06-16
Use of robotics for radioactive waste shipping and receiving
International Nuclear Information System (INIS)
Radioactive waste shipping and receiving facilities presently planned for commercial and defense high-level nuclear waste will handle waste packages at frequencies far in excess of those in common practice today. If current limits for radiation levels at the cask surface and current handling methods are used, high cumulative personnel exposure to ionizing radiation is projected to occur. To reduce these exposure levels, alternate handling methods are being developed and demonstrated. The production nature of cask receiving operations, suggests commercial robotics be incorporated into a remote handling system to reduce predicted worker exposure to acceptable levels while maintaining or increasing throughput. The first phase of cask handling system development culminated in a proof-of-principle test demonstrating the feasibility of performing cask receiving and unloading operations in a remote and partially automated manner.
1986-06-16
Use of commercial robotics in radioactive waste shipping and receiving
International Nuclear Information System (INIS)
Radioactive waste shipping and receiving facilities presently planned for commercial and defense nuclear waste will handle waste packages at frequencies far in excess of those in common practice today. Unacceptable personnel exposure to ionizing radiation is projected to occur if current limits for radiation levels at the cask surface and current handling methods are used. To reduce these exposure levels, alternate handling methods are being developed and demonstrated. The production nature of cask receiving operations suggests commercial robotics be incorporated into a remote handling system to reduce predicted worker exposure to acceptable levels, while maintaining or increasing throughput. The first phase of cask handling system development culminated in a proof-of-principle test demonstrating the feasibility of performing cask receiving and unloading operations in a remote and partially automated manner. 6 refs., 12 figs.
1985-04-21
Upper bound for a three-photon excitation cross section in atomic argon in the ultraviolet regime
International Nuclear Information System (INIS)
A scheme of evaluating a generalized three-photon excitation cross section #sigma#/sub (3)/ in neutral atomic argon at 3144.67 A is outlined. Three photons at this wavelength can excite the neutral argon atoms from the ground 3p"6 "1S_0 state to the 3p"54s'[1/2]_1"0 state. The fourth photon will ionize the argon atoms. Assuming linear polarization of the incident laser radiation, contributions from several channels in various energy-level schemes are summed in the evaluation of the transition probability. For a laser linewidth of #DELTA##lambda#/sub L/ = 1 A, our maximum numerical value of the computed result for the three-photon excitation cross section is #sigma#/sub (3)/ = 1.414 x 10/sup -80/ cm"6 s"2. .AE.
8800-01-01
Traveling Wave RF Systems for Helical Cooling Channels
Energy Technology Data Exchange (ETDEWEB)
The great advantage of the helical ionization cooling channel (HCC) is its compact structure that enables the fast cooling of muon beam 6-dimensional phase space. This compact aspect requires a high average RF gradient, with few places that do not have cavities. Also, the muon beam is diffuse and requires an RF system with large transverse and longitudinal acceptance. A traveling wave system can address these requirements. First, the number of RF power coupling ports can be significantly reduced compared with our previous pillbox concept. Secondly, by adding a nose on the cell iris, the presence of thin metal foils traversed by the muons can possibly be avoided. We show simulations of the cooling performance of a traveling wave RF system in a HCC, including cavity geometries with inter-cell RF power couplers needed for power propagation.
2009-05-01
Trace analysis in cadmium telluride by heavy ion induced X-ray emission and by SIMS
International Nuclear Information System (INIS)
The possibilities of using both selective heavy ion induced X-ray emission and secondary ion mass spectroscopy (SIMS), for the identification of impurities present at low concentrations in cadmium telluride are examined. The relative concentrations of the impurities along CdTe crystals have been determined by exciting the X-ray emission of the elements in several slices with Ar and Kr ions and by comparing the relative characteristic X-ray emission yields. As a consequence of the quasimolecular inner shell ionization mechanism in heavy ion-atom collisions, Ar and Kr ions allow a strong excitation of the main impurities seen by SIMS namely Si, Cl and Ge, As, with only a minor contribution of Cd and Te. From the changes of the concentrations of the various impurities along the crystal, informations about segregation coefficients and compensation can be obtained.
2007-02-01
The propagation of relativistic heavy ions in multielement beam lines.
We describe calculations of the energy loss, range, stopping power, multiple scattering, and other related properties of a high-energy heavy-ion beam at any one of a set of beam line elements. A beam line element (e.g., any beam modification, detection, or control device) is characterized by its thickness, areal density, aperture, and function. The loss of multiply scattered particles to any finite-aperture detector is calculated in the small-angle approximation, and the position of the Bragg peak, as given by particles stopping in the second of two ionization chambers used for Bragg curve measurements, is estimated. A general purpose computer program, PROPAGATE, has been written to allow addition, deletion, and modification of the beam line elements used in the calculation and to provide a convenient means of repeating such calculations for arbitrary beam lines. Calculations and experimental measurements are compared and found to be in satisfactory agreement. ...
The energy dependence of L_#alpha#/L_l X-ray intensity ratio produced by heavy-ion bombardment
International Nuclear Information System (INIS)
The energy dependence of the Yb and Au L_#alpha#/L_l X-ray intensity ratio, produced by 0.5 - 3.0 MeV/u Li, Be, C, N, F, and Si ion bombardment (Malhi and Gray, Phys. Rev. A 44, 7199, (1991)), measured at 90"0 relative to the beam axis, has been explained. While for light ion impact the behaviour of the alignment parameter as a function of impact velocity is dominant, for the impact of heavier ions the multiple ionization effects become important. Using Larkins' prescription in the last case, calculations have been performed, which agree well with the data over the whole energy range investigated. (Author).
1993-01-01
The Dynamical Interaction of AGN with their Galaxian Environments
Jet-driven shocks are responsible for an important fraction of the emission of the narrow-line regions (NLRs) in many classes of AGN. However, this cannot explain all observations. It is clear that the remaining sources are photoionised by the active nucleus. The 2-d hydrodynamic models from the RSAA group support an evolutionary scenario whereby the shock-excited NLRs are initially jet-driven but later, ionizing photons from the central engine replace shocks as the main excitation mechanism and shock induced star formation may also become important. In their photoionized phase, dusty and radiation-pressure dominated evolution produces a self-regulated NLR spectrum. This model aso explains the coronal emission lines and fast (3000 km s$^{-1}$) outflows seen in some Seyferts.
2003-01-01
The Development of 6061-Aluminum Windows for the MICE LiquidAbsorber
Energy Technology Data Exchange (ETDEWEB)
The thin windows for the Muon Ionization Cooling Experiment (MICE) liquid Absorber will be fabricated from 6061-T6-aluminum. The absorber and vacuum vessel thin windows are 300-mm in diameter and are 180 mm thick at the center. The windows are designed for an internal burst pressure of 0.68 MPa (100 psig) when warm. The MICE experiment design calls for changeable windows on the absorber, so a bolted window design was adopted. Welded windows offer some potential advantages over bolted windows when they are on the absorber itself. This report describes the bolted window and its seal. This report also describes an alternate window that is welded directly to the absorber body. The welded window design presented permits the weld to be ground off and re-welded. This report presents a thermal FEA analysis of the window seal-weld, while the window is being welded. Finally, the results of a test of a welded-window are presented.
2005-08-24
The Brazilian Bragg curve detector built for AMS studies
Energy Technology Data Exchange (ETDEWEB)
A Bragg curve detector (BCD) has been designed and built to be used for AMS purposes. Its design is described and its performance, obtained in tests at the Australian National University (ANU), is reported. At a {sup 36}Cl energy of 154 MeV, the energy resolution was found to be 0.38%, and the charge resolution 1.3%. The {sup 36}Cl and {sup 36}S are completely discriminated. Good separation was also achieved at 64 MeV, and a measurement at this energy of the {sup 36}Cl/Cl ratio of a sample measured previously at 154 MeV with the standard ANU ionization detector agreed well with the earlier value. This very simple detector has been shown to be suitable for use in AMS programs.
2000-10-01
Structure of Mgn and Mg n + clusters up to n = 30
British Library Electronic Table of Contents (United Kingdom)
We present structure calculations of neutral and singly ionized Mg clusters of up to 30 atoms, as well as Na clusters of up to 10 atoms. The calculations have been performed using density functional theory (DFT) within the local (spin-)density approximation, ion cores are described by pseudopotentials. We have utilized a new algorithm for solving the Kohn-Sham equations that is formulated entirely in coordinate space and, thus, permits straightforward control of the spatial resolution. Our numerical method is particularly suitable for modern parallel computer architectures; we have thus been able to combine an unrestricted simulated annealing procedure with electronic structure calculations of high spatial resolution, corresponding to a plane-wave cutoff of 954 eV for Mg. We report the geo...
2011-01-01
Stability of space-charge neutralized beams
Consideration is given to the stability of negative ion beams which are neutralized through ionization of a background gas. Two types of instabilities are examined. First, beam-plasma instabilities are analyzed with the dispersion relation showing that they are unimportant if the beam velocity is less than the electron thermal velocity. Second, results of a computer simulation on the flow of a cylindrical beam and the resulting background plasma show that when the background neutral gas density is less than or approximately equal to a critical density as instability occurs. This critical density is the density that would be needed to space-charge neutralize the beam if the positive ions were not retarded by the beam. An approximate dispersion relation indicates that the nature of the instability is a transverse positive-ion acoustic wave which couples to the beam.
1977-09-22
Smoothing of laser energy deposition by gas jets
International Nuclear Information System (INIS)
Smoothing of laser beam non-uniformities using gas jets has been studied. The experiment has been performed with the PALS (Prague Asterix Laser System) laser working at 0.44 ?m with an intensity of about 1015 W/cm2. The laser beam has been split in two by a prism thus creating an artificial large-scale non-uniformity (? 90 ?m). We recorded time resolved and static images of laser-gas jet interaction with and without an Al target. Multi 1-dimensional and 2-dimensional simulations show that such interaction acts redistributing the over-intensities over larger surface. This effect has to be attributed to ionization processes with consequent laser beam refraction. Results show that Argon gas jet produces a strong refraction of the laser beam thus strongly reducing the initial two spots separation. (authors)
2009-08-01
Single-event dynamics of high-performance HBTs and GaAs MESFETs
Energy Technology Data Exchange (ETDEWEB)
Picosecond charge-collection transients measured for GaAs/AlGaAs HBTs following 3.0 MeV [alpha]-particle and 620 nm picosecond laser excitation reveal charge-collection efficiencies up to twenty-eight times smaller than for GaAs MESFETs, with [approximately]90% of the charge collected within 75 ps of the ionizing event. The small charge-collection efficiency of the HBTs is a consequence of the ultrafast charge-collection dynamics in these devices. The authors show that picosecond laser excitation reproduces nicely the ion-induced transients, providing a valuable tool for the investigation of charge-collection and SEU phenomena in these devices.
1993-12-01
We present mid-infrared spectro-imagery and high-resolution spectroscopy ofthe Orion bar and of a region in the Orion nebula. These observations have beenobtained in the Guaranteed Time with the Circular Variable Filters of the ISOcamera (CAM-CVF) and with the Short Wavelength Spectrometer (SWS), on board theEuropean Infrared Space Observatory (ISO). Our data shows emission fromamorphous silicate grains from the entire HII region and around the isolatedO9.5V star Theta2 Ori A. The observed spectra can be reproduced by a mixture ofinterstellar silicate and carbon grains heated by the radiation of the hotstars present in the region. Crystalline silicates are also observed in theOrion nebula and suspected around Theta2 Ori A. They are probably ofinterstellar origin. The ionization structure and the distribution of thecarriers of the Aromatic Infrared Bands (AIBs) are briefly discussed on thebasis of the ISO observations.
2000-01-01
British Library Electronic Table of Contents (United Kingdom)
A renewed interest in chemical fractionation of soil organic matter (SOM) originates from the premise that it enables to isolate labile SOM from SOM protected through mineral binding and recalcitrant SOM. Both selective removal of labile non-bound SOM through oxidation or hydrolysis as well as selective removal of minerals and attached SOM are often applied. Molecular-level SOM characterization by means of temperature resolved Pyrolysis-Field Ionization Mass Spectroscopy analysis (Py-FIMS) was used here as an approach to obtain insight into the fate of SOM upon wet chemical treatment with regard to composition and thermal stability. The applied sequential chemical treatment with 6% NaOCl and 10% HF yielded similar sizes in stable SOM fractions between sandy semi-native heathland and cultiv...
2009-01-01
Segmented focal plane detector for light and heavy ions
Energy Technology Data Exchange (ETDEWEB)
A segmented focal plane detector for an Enge split-pole spectrograph has been developed for the study of breakup reactions at very low relative energies. It consists of a 61 cm long segmented position-sensitive parallel plate avalanche counter backed by a large Bragg curve detector. A segmented plastic scintillator is mounted behind the anode of the Bragg curve detector and is used for particle identification of low-ionizing particles. The dead space between the two sections of the focal plane detector is 2.5 mm. The intrinsic position resolution of the detector is 1 mm. The intrinsic energy resolution depends on the energy of the incident ion and can be as good as 0.55%. The nuclear charge and mass resolutions are 0.3 e and 0.3 u, respectively. (orig.).
1992-06-15
Secondary electron yield measurements from thin surface coatings for NLC electron cloud reduction
In the beam pipe of the positron damping ring of the Next Linear Collider, electrons will be created by beam interaction with the surrounding vacuum chamber wall and give rise to an electron cloud. Several solutions are possible for avoiding the electron cloud, without changing the bunch structure or the diameter of the vacuum chamber. Some of the currently available solutions for preventing this spurious electron load include reducing residual gas ionization by the beam, minimizing beam photon-induced electron production, and lowering the secondary electron yield (SEY) of the chamber wall. We will report on recent SEY measurements performed at SLAC on TiN coatings and TiZrV non-evaporable getter thin films.
2004-01-01
Risk assessment for radiation protection purposes
International Nuclear Information System (INIS)
In defining criteria for good protection against ionizing radiation, it is important to assess quantitatively the likely risk of any radiation exposure. The 'somatic' risks to the individual result mainly from induction of cancer in the organs irradiated, and these risks can now be estimated on the basis of numerous detailed epidemiological surveys of exposed human populations. Estimates of the risk of hereditary effects, from genetic changes induced in germ cells, are based largely on the frequency with which such effects are induced in other species. In both cases the risk at very low dose can be inferred using knowledge of the way in which radiation damage is caused in tissues. Coherent systems of radiation protection are based on a restriction of doses to the whole body and to individual organs, such that the induction of cancer and genetic harm is infrequent, and the threshold dose for causing other, 'non-stochastic', effects is not exceeded. (author).
1980-01-01
British Library Electronic Table of Contents (United Kingdom)
This study emphasizes the need for a systematic and in-depth connection between the progress in quantum theory of energetic ion collisions and applications to hadron therapy. Scattering theory for fast ion beams has reached its stage of development where accurate and robustly applicable methodologies can advantageously be exported to applied fields such as space research, fusion energy program, medicine, etc. In particular, distorted wave collision theories at high energies readily provide total, partial and fully differential cross sections for inelastic collisions of ionic projectiles with any target system. By numerous and thorough testings, such theoretical cross sections were found to exhibit excellent agreement with experimental data on atomic targets. Adequate extensions of these me...
2010-01-01
International Nuclear Information System (INIS)
The point at which the common final pathway for induction of cancer by chemical carcinogens and ionizing radiation has not been identified. Although common molecular targets are suggested by recent findings about the role of oncogenes, the mechanism by which the deposition of radiation energy and the formation of adducts or other DNA lesions induced by chemicals affects the changes in the relevant targets may be quite different. The damage to DNA that plays no part in the transformation events, but that influences the stability of the genome, and therefore, the probability of subsequent changes that influence tumorigenesis may be more readily induced by some agents than others. Similarly, the degree of cytotoxic effects that disrupt tissue integrity and increase the probability of expression of initiated cells may be dependent on the type of carcinogen. Also, evidence was presented that repair of the initial lesions could be demonstrated after exposure to low-LET ...
1984-05-20
Relativistic distorted-wave results for nickel-like gadolinium
Electron collisional data are required for population kinetics modeling and spectral predictions of highly ionized ions in high-temperature plasmas. Nickel-like ions are especially interesting for their potential use in soft X-ray laser schemes pumped by electron collisional excitation and recombination. For highly stripped ions of moderate to high Z, relativistic effects begin to play a role in the atomic-physics calculations. A relativistic multiconfigurational distored-wave model has been used for the calculation of electron excitation cross sections and rate coefficients between the 3s2 3p6 3d10 Ni-like Gd ground state and the singly excited states with an N-shell electron.
1986-08-01
British Library Electronic Table of Contents (United Kingdom)
Analytical methods developed to sample and characterize ambient organic aerosols often face the trade-off between long sampling times and the loss of detailed information regarding specific chemical species present. In the work presented here, high-time resolution ambient measurements (3.5 minutes) are achieved by using the Photoionization Aerosol Mass Spectrometer (PIAMS) in conjunction with the mini-Versatile Aerosol Concentration Enrichment System (m-VACES). Aerosol sampling took place for one week at State of Delaware Air Quality Monitoring Site in Wilmington, Delaware in June 2006. The soft, universal ionization scheme of PIAMS allows for identification of various chemical compounds by a signature ion, often the molecular ion. Meteorological data was used to link some species, such as...
2008-01-01
Radiation protection. A guide for scientists and physicians
International Nuclear Information System (INIS)
This manual was written for individuals who wish to become qualified in radiation protection as an adjunct to working with sources of ionizing radiation or using radionuclides in the field of medicine. It provides the radiation user with information needed to protect himself and others and to understand and comply with governmental and institutional regulations regarding the use of radionuclides and radiation machines. It is designed for a wide spectrum of users, including physicians, research scientists, engineers, and technicians. It should be useful also to radiation safety officers, members of radiation safety committees, and others who are responsible for the proper use of radiation sources, although they may not be working with the sources directly. The presentation in this manual is designed to obviate the need for reviews of atomic and radiation physics, and the mathematics has been limited to elementary arithmetical and algebraic operations.
R46 and pKM101 plasmid-mediated resistance to ionizing radiation in Escherichia coli
International Nuclear Information System (INIS)
The ability of the R46 R factor and its derivative pKM101 to modify sensitivity to "6"0Co #gamma# radiation was studied. In Escherichia coli K12 both plasmids enhanced bacterial survival after "6"0Co #gamma# irradiation. This effect was dependent on recA"+ genotype but not on recB"+, recB"+recC"+, and recF"+ genotypes. 5-Fluorouracil eliminated the R46 R factor from the parent and its rec"- mutant strains. These strains lost not only the antibiotic resistance coded for R46 R factor but their radioresistance as well.
Progress on the Design and Fabrication of the MICE Focusing Magnets
Energy Technology Data Exchange (ETDEWEB)
The Muon Ionization Cooling Experiment (MICE) focusing solenoid magnets focus the muon beam within the MICE cooling channel on a liquid or solid absorber that is within the warm bore of solenoid. The focusing magnet has a warm bore of 470 mm. his magnet consists of two coils 210-mm long that is separated by an aluminum mandrel that is 200 mm long. Each of the coils has its own leads. The coils may be operated in either the non-flip mode (solenoid mode with both coils at the same polarity) or the lip mode (quadrupole focusing mode where both coils are at opposite polarity). This report describes the focusing solenoid magnet design that will be built by the vendor. The progress on the construction of the first of the focusing magnets will also be discussed in this report. Ultimately three of these magnets will be built. These magnets will be cooled using a pair 1.5 W (at 4.2 K) pulse tube coolers.
2009-10-19
Plane electrode device for multiwire detector for ionizing radiations
International Nuclear Information System (INIS)
A multiwire proportional counter type detector with thin slits instead of wires is presented. It can detect either charged particles (positive or negative) or radiation. The detector can be used as a counter or as an image converter. In radiography, it can replace photographic film or TV camera systems. It can also be used to measure particle or radiation energy. The slits which replace wires in the anode are introduced between two parallel microstrip conductors with different potentials. A quasi-polar electric field is produced between these strips. To obtain high fields, the slits are extremely narrow. Microstrips less than a micron can be obtained, giving structural dimensions of a few microns, i.e., 100 times smaller than the spacing in a classic wire anode.
1986-07-01
Physical and mathematical description of Nuclear Weapons Identification System (NWIS) signatures
Energy Technology Data Exchange (ETDEWEB)
This report describes all time and frequency analysis parameters measured with the new Nuclear Weapons Identification System (NWIS) processor with three input channels: (1) the {sup 252}Cf source ionization chamber; (2) a detection channel; and (3) a second detection channel for active measurements. An intuitive and physical description of the various functions is given as well as a brief mathematical description and a brief description of how the data are acquired. If the full five channel capability is used, the number of functions increases in number but not in type. The parameters provided by this new NWIS processor can be divided into two general classes: time analysis signatures including multiplicities and frequency analysis signatures. Data from measurements with an 18.75 kg highly enriched uranium (93.2 wt%, {sup 235}U) metal casting for storage are presented to illustrate the various time and frequency analysis parameters.
1997-09-26
Physical and Mathematical Description of Nuclear Weapons Identification System (NWIS) Signatures
Energy Technology Data Exchange (ETDEWEB)
This report describes all time and frequency analysis parameters measured with the new Nuclear Weapons Identification System (NWIS) processor with three input channels: (1) the 252Cf source ionization chamber (2) a detection channel; and (3) a second detection channel for active measurements. An intuitive and physical description of the various functions is given as well as a brief mathematical description and a brief description of how the data are acquired. If the fill five channel capability is used, the number of functions increases in number but not in type. The parameters provided by this new NWIS processor can be divided into two general classes: time analysis signatures including multiplicities and frequency analysis signatures. Data from measurements with an 18.75 kg highly enriched uranium (93.2 wt 0/0, 235U) metai casting for storage are presented to illustrate the various time and frequency analysis parameters.
1997-09-26
Energy Technology Data Exchange (ETDEWEB)
The biological effects of ionizing radiation exposure are the result of a complex sequence of physical, chemical, biochemical, and physiological interactions. One way to begin a search for an understanding of health effects of radiation is through the development of phenomenological models of the response. Many models have been presented and tested in the slowly evolving process of characterizing cellular response. A range of models covering different endpoints and phenomena has developed in parallel. Many of these models employ similar assumptions about some underlying processes while differing about the nature of others. An attempt is made to organize many of the models into groups with similar features and to compare the consequences of those features with the actual experimental observations. It is assumed that by showing that some assumptions are inconsistent with experimental observations, the job of devising and testing mechanistic models can be simplified. ...
1990-09-01
Performance of a Bragg curve detector for heavy ion identification
Energy Technology Data Exchange (ETDEWEB)
By using Bragg curve spectroscopy, one can measure atomic number and energy of high energy heavy ions stopping in a gas-filled ionization chamber with longitudinal electric field. In this paper, we report on the results obtained with an isobutane filled detector. An energy resolution of 0.8% fwhm and a Z resolution of 2.7% fwhm were achieved for elastically scattered 300 MeV /sup 40/Ar ions. We study the Bragg peak amplitude dependence on the energy of the incoming ions, a dependence presumably due to the Frisch grid screening inefficiency. The corrected Bragg peak spectrum of inelastically scattered 300 MeV /sup 40/Ar ions exhibits a satisfactory Z separation around Z = 18.
1982-12-15
Performance of a Bragg curve detector for heavy ion identification
International Nuclear Information System (INIS)
By using Bragg curve spectroscopy, one can measure atomic number and energy of high energy heavy ions stopping in a gas-filled ionization chamber with longitudinal electric field. In this paper, we report on the results obtained with an isobutane filled detector. An energy resolution of 0.8% fwhm and a Z resolution of 2.7% fwhm were achieved for elastically scattered 300 MeV "4"0Ar ions. We study the Bragg peak amplitude dependence on the energy of the incoming ions, a dependence presumably due to the Frisch grid screening inefficiency. The corrected Bragg peak spectrum of inelastically scattered 300 MeV "4"0Ar ions exhibits a satisfactory Z separation around Z = 18. (orig.).
Particle identification for heavy ions in a time-of-flight spectrometer
Energy Technology Data Exchange (ETDEWEB)
A time-of-flight (TOF) spectrometer has been constructed at the JAERI 20 MV tandem accelerator facility. A position-sensitive start detector, which consists of a thin carbon foil, microchannel plates and a resistive plate, was developed for the TOF measurements through the spectrometer. The time and position resolutions obtained were 120 ps and 0.3 mm for ..cap alpha.. particles from /sup 241/Am, respectively. A two-dimensional position-sensitive detector was also developed to measure the solid angle of the spectrometer and the maximum solid angle obtained was 9.5 msr. As a particle detector a Bragg curve ionization chamber was developed. From the Bragg curves of heavy ions in the detector, energies, ranges and Bragg curve peaks were measured and used for particle identification. The resolving power Z/..delta..Z of the atomic number was about 50.
1982-05-01
Paediatric radiography - the avoidance of late radiation damage to the growing hip
Energy Technology Data Exchange (ETDEWEB)
Epiphyseal plates of growing bones are sensitive to ionizing radiation and this poses problems for the paediatric radiotherapist. In this case report we describe a child in whom electron beam therapy to the groin delivered only low dose radiation to the proximal hip epiphyses - 130 cGy fractionated over 5 weeks - but who suffered late maldevelopment. We explore the success of various radiotherapy techniques in minimizing the dose to the hip epiphyses in four other children. The appropriate positioning of the limb, the choice of treatment modality and, where possible, individual shielding blocks are considered and their effect on the dose to the hip estimated. Absorbed doses of radiation delivered to the midpoint of the proximal femoral epiphyses have been retrospectively determined. (author).
1993-04-01
Overview of Cooling Water System for the KSTAR 1st Plasma Experiment
International Nuclear Information System (INIS)
The KSTAR cooling water system (CWS) consists of a primary cooling water system (PCWS), a secondary cooling water system (SCWS), and a de-mineralizing and de-ionized water system (DIWS). The PCWS cooling loops have been made for the poloidal field (PF) and toroidal field (TF) magnet power supplies (MPS), vacuum vessel (VV), electron cyclotron heating (ECH), ion cyclotron heating (ICRH), vacuum pumps, diagnostics, helium facility, etc. The CWS had been done individual commissioning of each system to confirm the design specifications by the end of 2006 and had gradually begun operation for the KSTAR ancillary devices by March 2008
2009-05-01
Ocular Burn: Rinsing and Healing with Ionic Marine Solutions and Vegetable Oils
British Library Electronic Table of Contents (United Kingdom)
Abstract Purpose: We investigated the effects of various rinsing and healing protocols on corneal wound repair and inflammation following alkali burn in rabbits. Methods: We conducted in vitro, in vivo and ex vivo studies. First, different rinse solutions were tested in vitro after incubation of ocular cells with methanol or NaOH. Cell viability was then assessed using the neutral red test (cytofluorometry). Second, NaOH was applied to rabbit corneas and associations of rinse solutions (NaCl 0.9% or controlled ionization marine solutions) with N-acetylcysteine or vegetable oils (from Calophyllum inophyllum and Aleurites moluccana) were tested in vivo. The regeneration of the corneal epithelium and the infiltration of inflammatory cells were evaluated using in vivo confocal microscopy and e...
2009-01-01
OBSERVATION OF NUCLEAR PARTICLE TRACKS IN THE ELECTRON MICROSCOPE
A fine-grained photosensitive layer was prepared for electron- microscopic radioautography. The layer was obtained by evaporating Ag at low pressure and temperature on electron microscope grids and sensitizing the silvered grids with Br/sub 2/. The resulting particles had an average diameter of -- 100 A. The sensitivity of the layer to ionizing radiation was tested by sprinkling the grids with fine uranium aeetate particles and examining the processed grids in an electron microscope. Shont tracks and side spurs were observed which are probably due to alpha radiation from U/sup 235/ and secondary electrons scattered from the silver, respectively. Tests with P/sup 32/- phosphate are also described. (D.L.C.)
1962-08-01
Numerical simulation of a pulsed corona discharge plasma
In this paper we study theoretically a pulsed corona discharge plasma in air at atmospheric pressure. A self consistent one-dimensional model, using a flux-corrected transport numerical scheme, is presented to achieve it. The charged particle kinetics in this model are described by one-dimensional continuity equations coupled with Poisson's equations. The spatio-temporal local field, charge density variations and the velocity profile of an ionizing front are calculated to describe the dynamical behavior of corona discharge plasmas. The simulation results of a wire-in-cylinder corona discharge plasma explain the physical mechanisms of discharge processes. These results may also be apply to obtain the optimizing parameters for designing the plasma reactor.
2001-10-01
Neutron-induced fission cross-section of {sup 233}U in the energy range 0.5<E{sub n}< 20 MeV
Energy Technology Data Exchange (ETDEWEB)
The neutron-induced fission cross-section of {sup 233}U has been measured at the CERN n-TOF facility relative to the standard fission cross-section of {sup 235}U between 0.5 and 20MeV. The experiment was performed with a fast ionization chamber for the detection of the fission fragments and to discriminate against {alpha} -particles from the natural radioactivity of the samples. The high instantaneous flux and the low background of the n-TOF facility result in data with uncertainties of {approx} 3%, which were found in good agreement with previous experiments. The high quality of the present results allows to improve the evaluation of the {sup 233}U (n,f) cross-section and, consequently, the design of energy systems based on the Th/U cycle. (orig.)
2011-01-15
Energy Technology Data Exchange (ETDEWEB)
The crystal structure of Ca{sub 2}RuD{sub 6} has been determined by neutron powder diffraction: space group Fm3m, K{sub 2}PtCl{sub 6} structure, as found for other hexahydride salts of group 8 metals with alkaline earth or lanthanide counter ions. No structural phase transition was observed between 340 K and 50 K. The deuterium nuclear quadrupole coupling constant, 54.7 kHz, leads to an ionic character of the Ru-D bond of 76%. The known trends in the behaviour of A{sub 2}MH{sub 6} salts are interpreted in terms of the ionization energies of the cation and the central metal atom.
2008-07-28
British Library Electronic Table of Contents (United Kingdom)
The crystal structure of Ca2RuD6 has been determined by neutron powder diffraction: space group Fm3m, K2PtCl6 structure, as found for other hexahydride salts of group 8 metals with alkaline earth or lanthanide counter ions. No structural phase transition was observed between 340K and 50K. The deuterium nuclear quadrupole coupling constant, 54.7kHz, leads to an ionic character of the Ru-D bond of 76%. The known trends in the behaviour of A2MH6 salts are interpreted in terms of the ionization energies of the cation and the central metal atom.
2008-01-01
British Library Electronic Table of Contents (United Kingdom)
We have studied the nature of continuum emitted in the visible spectral range from a noncontracted positive column of discharge in a cesium vapor-xenon mixture at a pressure of 45 Torr and at a degree of ionization below 3 ? 10?6. The main contribution to the continuous emission under such conditions is due to electron-xenon atom bremsstrahlung. The intensity of emission has been experimentally and theoretically studied as a function of the electric field strength and electron density in the positive column. It is established that an increase in the visible emission intensity with the electric field strength is related to an increase in the number of hot electrons in plasma.
2007-01-01
International Nuclear Information System (INIS)
Relative doses of 75 MeV/u "1"2C ion beam after passing through different thickness of degraders were measured with the double ionization chamber method. The degrader's thickness equalized to penetration depth of the beam in water and its Bragg curve were obtained. The measured Bragg curve is compared with that calculated based on a model set up by the authors. Meanwhile, the inactivation effect of the ion beam passing through different thickness of degraders on melanoma (B_1_6) cells was measured, and the corresponding survival fraction data for B_1_6 cells were acquired
1998-08-01
Measurements and calculations of M-shell X-ray production in Er, Yb and Lu by 0.75-6 MeV He ions
Energy Technology Data Exchange (ETDEWEB)
M-shell X-ray production cross sections for the light rare-earth elements of {sup 68}Er, {sup 7}Yb and {sup 71}Lu have been measured for incident {sup 4}He{sup +} ions in the energy range from 0.75 to 6 MeV. The measured X-ray production cross sections are compared to the predictions of the First Born approximation, the ECPSSR theory and the ECUSAR theory. A comparison of the ytterbium M-shell X-ray production cross sections with these theories is made for two different sets of fluorescence yields and Coster-Kronig factors that are further modified for multiple ionization.
2005-12-15
British Library Electronic Table of Contents (United Kingdom)
Samples of vitamin D fortified orange juice obtained from retail food stores were analyzed for vitamin D3 content using a method developed by combining the best features of two AOAC methods. Detection by ultraviolet absorption at 265nm was compared to detection by selected ion monitoring (SIM) using atmospheric pressure chemical ionization (APCI) mass spectrometry (MS). Furthermore, an ion trap (IT) mass spectrometer was employed in a 'dual parallel MS' arrangement to simultaneously obtain qualitative APCI-ITMS data. The method was applied to 33 samples of 3 national American orange juice brands and 7 samples of 5 other American brands collected using a statistically designed sampling plan as part of the National Food and Nutrient Analysis Program to provide values for the USDA National Nu...
2011-01-01
Jets and accretion processes in Active Galactic Nuclei further clues
We present evidence in favour of a link between the luminosity radiatively dissipated in the central engine of radio-loud Active Galactic Nuclei and the kinetic power in their jets. This piece of evidence is based on the relation we find between the luminosity in broad emission lines and the kinetic power in pc-scale radio jets, for a sample of radio-loud quasars for which suitable data are available in the literature. We find that the ionizing luminosity and the kinetic one are of the same order of magnitude, suggesting that the processes responsible for them are somehow related. A strong magnetic field in equipartition with the radiation field could be responsible for regulating both processes. BL Lac objects seem to follow a similar behaviour, but with comparatively fainter broad line emission.
1996-01-01
Irradiation of human insulin in aqueous solution, first step towards radiosterilization
British Library Electronic Table of Contents (United Kingdom)
The degradation of irradiated human insulin in aqueous solutions was investigated in order to protect the protein against ionizing radiation. The influence of the drug concentration, excipients and irradiation temperature were studied.Aqueous solutions at pH 2 were irradiated by gamma rays or by accelerated electrons. Two different high-performance liquid chromatography (HPLC) methods were used: reverse-phase high-performance liquid chromatography (RP-HPLC)/UV and size exclusion liquid chromatography (SEC/UV) to investigate both the fragmentation and the formation of higher molecular weight proteins.In solution without excipients irradiated at ambient temperature at 10kGy, the loss of human insulin is almost complete. Addition of radio-protecting excipients (free radicals scavengers) and c...
2007-01-01
Ionizing radiation effect on sealant properties
International Nuclear Information System (INIS)
Presented are the investigation results of electrophysical and physico-mechanical properties of KLF-20, Viksint U-4-21, Viksint KT-73, UF-7-21, KG-184, KL-4, KL-16SE-305, VIAT-1 and PPK-21 sealants, irradiated with sources of continuous and pulse #gamma#-radiation, as well as pulse #gamma#-neutron radiation. It is shown that electrophysical and physico-mechanical properties of sealants after irradiation by continuous #gamma#-radiation up to 10"6 doses and pulse gamma-neutron radiation with neutron fluence of 10"1"3 neutron/cm"2 and #gamma#-radiation dose of 10"4R do not practically change. Electric conductivity and tangent of the angle of dielectric losses increase in the process of irradiation. Electric conductivity depends on irradiation type, is proportional to dose rate and does not depend on temperature and pulse duration.
IAEA RESEARCH CONTRACTS FIRST ANNUAL REPORT. Technical reports Series No. 4
Summaries are included of research contracts which expired prior to Dec. 31, 1960. The contracts were concerned with investigations of: electrophysiological responses of biological systems in nerve cells to irradiation with small doses of ionizing radiations; the mode of the protective action of certain sulfhydryl compounds against radiation effects on the synthesis of deoxyribonucleic acid, using tritium-labeled thymidine; development of a bubble chamber method of monitoring and dosimetry for Low fast neutron fluxes; effects of incorporated radioisotopes on the stability of genetic materials; interrelation of root and leaf absorption of radioisotopes in herbaceous plants; uptake of radioactive wastes by lowland rice from soils contaminated by irrigation water, and decontamination of the rice; and comparison between mutation rates induced by acute and chronic gamma irradiations. (B.O.G.)
1961-01-01
Health risks arising from ionizing radiation and chemical pollutants
International Nuclear Information System (INIS)
In quantifying health risks arising from radiation exposure and synergistic effects promoted by radiation the dose-effect relationship must be used as a basis. Special problems arise in the extrapolation of experimental results or in the treatment of data in the region of low doses administered over long periods of time. For radiation protection purposes, especially manifestations of cancer and genetic effects are significant. The International Commission on Radiation Protection has published binding guiding values on the basis of which to assess the risk of cancer. The cancer risk and genetic risks are estimated for relevant dose ranges and compared with other factors of civilization. For the most important chemical pollutants emitted into the environment the possibilities of impacts arising from synergistic effects are discussed on the basis of the rules and regulations specified in German antipollution legislation. (orig.) 891 HP/orig. 892 MKO.
1979-10-03
British Library Electronic Table of Contents (United Kingdom)
Single crystals of ytterbium tartrate trihydrate have been grown by gel method using silica and agar-agar gels as media of growth. The medium of growth influences the morphology of grown crystals, silica gel yielding single and polycrystalline in the form of spherulites whereas agar-agar gel leading to growth of single and twinned crystals. Materials grown as single crystals have been characterized by using optical and scanning electron microscopy (SEM), EDAX, XRD, FT-IR, CHN and thermogravimetric techniques. The stoichiometry of the grown single crystals is suggested to be Yb(C4H4O6) (C4H5O6).3H2O. The FT-IR spectrum shows the presence of singly as well as doubly ionized tartrate ligands. Results of thermal analysis indicate that the material is thermally stable up to a temperature of 200...
2006-01-01
British Library Electronic Table of Contents (United Kingdom)
ObjectivesTo assess the influence of epigallocatechin-3-gallate (EGCG) on the efficacy of ionizing radiation on prostate cancer cells because of the increased use of dietary interventions, especially by patients with prostate cancer. Radiotherapy is used to treat localized prostate cancer. Some people consume green tea (EGCG) as a chemopreventive agent against prostate cancer. Green tea can act as an antioxidant and induce superoxide dismutase enzymes, which could scavenge the free oxygen radicals generated by radiotherapy. MethodsProstate cancer cell line DU145 cells were treated with EGCG or radiotherapy, or both. Cell death was assessed using trypan blue cell counting, and apoptosis was confirmed by assessing poly (adenosine phosphate ribose) polymerase cleavage. The antioxidant potenti...
2011-01-01
Fourier analysis of energy transfer data obtained by simulating a 14-MeV #alpha#-particle in water
International Nuclear Information System (INIS)
Data from Monte Carlo transport codes are used to model radiobiological effects. We previously reported the Fourier analysis of ionization data generated by simulating a 500-keV proton traversing water. Here, we extend Fourier analysis to energy transfer data of another radiation type, a 14-MeV #alpha#-particle. A radiobiological model based on this frequency-domain analysis views cell as an information processing system . It lends itself naturally to traditional engineering analyses. One engineering principle-the output response of a linear system to random signal-is applied here to explain the fact that there is measurable difference in the magnitude of the biological effectiveness when a given biological system is irradiated with two different radiation types of the same Linear Energy Transfer (LET).
2010-01-15
Energy Technology Data Exchange (ETDEWEB)
A compact and supersensitive device that can rapidly detect minute trace vapors from concealed explosives has been developed by scientists at Oak Ridge National Laboratory (ORNL). The new explosives sensor can detect and chemically identify organic nitrogen-oxygen compounds which are the building blocks of explosives such as TNT, plastiques, and nitroglycerine. The device could be used to scan persons entering airport terminals, nuclear power plants, defense installations, or other sensitive locations, providing greater security against potential terrorism. This device works on a glow discharge principle, and is more specifically called an ''Atmospheric Sampling Glow Discharge Ionization'' (ASGDI) source. The new detector is a highly automated, miniaturized version of research mass spectrometers widely used to trace constituents of chemical mixtures. Detail of this device's construction and advantages are discussed in ...
1987-01-01
Experimental limits on quarks, tachyons, and massive particles in cosmic rays
Energy Technology Data Exchange (ETDEWEB)
A large detector with high redundancy is used to search for various types of anomalous particles in cosmic rays at sea level. The detector is sensitive to zenith angles between 45/sup 0/ and 90/sup 0/. Previously obtained limits on the fluxes of charge (1/3) and (2/3) particles are reduced to 2.9 x 10/sup -10/ and 2.6 x 10/sup -10/ cm/sup -2/sr /sup -1/ sec/sup -1/, respectively. The flux of ionizing tachyons is determined to be less than 2.4 x 10/sup -9/ cm/sup -2/ sr/sup -1/ sec/sup -1/. The massive-particle flux limit we obtain is inconsistent with previous claims of such particles assuming that these particles are isotropic in zenith angle.
1982-10-01
Experimental limits on quarks, tachyons, and massive particles in cosmic rays
International Nuclear Information System (INIS)
A large detector with high redundancy is used to search for various types of anomalous particles in cosmic rays at sea level. The detector is sensitive to zenith angles between 45"0 and 90"0. Previously obtained limits on the fluxes of charge (1/3) and (2/3) particles are reduced to 2.9 x 10"-"1"0 and 2.6 x 10"-"1"0 cm"-"2sr "-"1 sec"-"1, respectively. The flux of ionizing tachyons is determined to be less than 2.4 x 10"-"9 cm"-"2 sr"-"1 sec"-"1. The massive-particle flux limit we obtain is inconsistent with previous claims of such particles assuming that these particles are isotropic in zenith angle.
Experimental investigations of plasma bullets
International Nuclear Information System (INIS)
Recently several investigators reported on various means of generating cold plasma jets at atmospheric pressure. More interestingly, these jets turned out to be not continuous plasmas but trains of small high velocity plasma packets/bullets. However, until now little is known of the nature of these 'bullets'. Here we present experimental insights into the physical and chemical characteristics of bullets. We show that their time of initiation, their velocity and the distance they travel are directly dependent on the value of the applied voltage. We also show that these bullets can be controlled by the application of an external electric field. Using an intensified charge coupled device camera we report on their geometrical shape, which was revealed to be 'donut' shaped, therefore giving an indication that solitary surface ionization waves may be responsible for the creation of these bullets. In addition, using emission spectroscopy, we follow the evolution of ...
2009-03-07
Estimated fetal radiation dose from multislice CT studies
International Nuclear Information System (INIS)
It is often necessary to estimate the dose of radiation to a fetus from a series of CT scans. To assist in making this process easier and more accurate, we measured fetal doses in an adult anthropomorphic phantom for four CT scanners: Picker 1200, Siemens DRH, GE 9800, and GE 8800. Measurements were made at four kilovoltages (100, 120, 130, and 140 kVp), for 2-, 5-, 8-, and 10-mm thicknesses, for two scanning angles (360 degrees and 398 degrees) and for two patient orientations (prone and supine). The fetal-dose estimates are based on the CT dose index measured by using a pencil ionization chamber at the center position of a 16-cm-diameter cylindrical phantom. Comparison with data from other investigators shows reasonable agreement when phantom differences, X-ray tube output, and equipment calibration are considered.
Electrical properties and x-ray diffraction of wood and wood plastic composite (WPC)
Energy Technology Data Exchange (ETDEWEB)
Wood plastic composite (WPC) of kadom, simul, mango and debdaro were prepared with two monomers methylmethacrylate (MMA) and butylmethacrylate (BMA) using high energy ionizing radiation. X-ray diffraction and scanning electron microscope (SEM) studies reveal that significant grafting occurred with wood fiber. Electric properties like resistivity and dielectric constant of both wood and WPC were measured under different moisture contents and relative humidities. The resistivities of wood decreased dramatically with increase of moisture content, but those of WPC decreased very slowly with moisture content. The dielectric constant of wood increased significantly with moisture content but no significant difference was observed in the case of WPC within the range of moisture contents studied. The dielectric constants of untreated wood also increased with their densities. (author).
1991-01-01
Effect of radiation on certain animal viruses in liquid swine manure
International Nuclear Information System (INIS)
The virucidal effect of _6_0Co gamma radiation was studied in cell culture medium and in liquid swine manure involving the most important porcine viruses that can be spread by liquid manure. The radiation doses (20 kGy and 30 kGy) were determined in preliminary experiments employing a porcine enterovirus from the serogroup 1 (Teschen group). In the main experiment, the following viruses were employed: swine vesicular disease (SVD) virus, type C foot-and-mouth disease (FMD) virus, a field strain of Aujeszky's disease (AD) virus, transmissible gastroenteritis (TGE) virus, as well as bovine viral diarrhoea (BVD) virus. The latter strain served as a model for hog cholera virus. The results of the experiments indicate that safe disinfection of the virus infected liquid swine manure by ionizing radiation requires a radiation dose of 30 kGy. (author).
1983-01-01
British Library Electronic Table of Contents (United Kingdom)
To test the effect of humidity on the radiation resistance of Deinococcus radiodurans, air-dried cells were irradiated with germicidal 254?nm UV, and simulated environmental UV or ?-radiation and survival was compared to cells in suspension. It was observed that desiccated cells exhibited higher levels of resistance than cells in suspension toward UV or ?-radiation as well as after 85?C heat shock. It was also shown that low relative humidity improves survival during long-term storage of desiccated D. radiodurans cells. It can be concluded that periods or environments in which cells exist in a dehydrated state are beneficial for D. radiodurans? survival exposed to various other stresses.
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Past movement on faults can be dated by measurement of the intensity of ESR signals in quartz. These signals are reset by local lattice deformation and local frictional heating on grain contacts at the time of fault movement. The ESR signals then trow back as a result of bombardment by ionizing radiation from surrounding rocks. The age is obtained from the ratio of the equivalent dose, needed to produce the observed signal, to the dose rate. Fine grains are more completely reset during faulting, and a plot of age vs grain size shows a plateau for grains below critical size : these grains are presumed to have been completely zeroed by the last fault activity. We carried out ESR dating of fault rocks collected from the Yangsan fault system. ESR dates from the this fault system range from 870 to 240 ka. Results of this research suggest that long-term cyclic fault activity continued into the pleistocene.
2002-03-15
British Library Electronic Table of Contents (United Kingdom)
Purpose: In this paper, we present an alternative to the originally proposed technique for the delivery of spatially fractionated radiation therapy (GRID) using multi-leaf collimator (MLC) shaped fields. We employ the MLC to deliver various pattern GRID treatments to large solid tumors and dosimetrically characterize the GRID fields. Methods and materials: The GRID fields were created with different open to blocked area ratios and with variable separation between the openings using a MLC. GRID designs were introduced into the Pinnacle3 treatment planning system, and the dose was calculated in a water phantom. Ionization chamber and film measurements using both Kodak EDR2 and Gafchromic EBT film were performed in a SolidWater phantom to determine the relative output of each GRID design as w...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
The measurements of the K X-ray intensity ratio I(K{sub {beta}})/I(K{sub {alpha}}) for the 17 elements Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Se, Br, Rb, Sr, Y, Zr, Nb and Mo have been done following ionization by 59.5keV {gamma}-rays from a {sup 241}Am point source. Ratios of emission probabilities of Auger electrons and the vacancy transfer coefficients have been extracted in terms of the intensity ratios. It is found that the present results agree well with earlier fitted values and the semi-empirical values.
2006-01-15
Defect creation by electronic processes in MgO bombarded with GeV heavy ions
Energy Technology Data Exchange (ETDEWEB)
To study the defect creation induced by electronic processes in refractory oxides, MgO single crystals were irradiated with high energy tin, uranium and lead ions. Optical absorption measurements showed that F-type centers (oxygen vacancies with trapped electrons) were created during irradiation. The total number of centers per unit area of bombarded sample increases linearly with irradiating fluence. The main part of the point defects was found to arise from electronic processes. The concentration of F-type centers induced by ionization increases with the electronic energy losses. Assuming a saturation of point defect concentration at high fluences, F-type center creation cross sections could be estimated. The influence of irradiation temperature and of the velocity of the bombarding ions are discussed.
1996-12-31
Decay of very neutron-rich Mn nuclides and vanishing of the N=40 subshell closure in {sup 66}Fe
The use of chemically selective laser ionization combined with beta-delayed neutron counting at ISOLDE has permitted identification and half-life measurements for {sup 61}Mn up through {sup 69}Mn. The 14(4)-ms half life for {sup 69}Mn is one of the shortest determined for any nuclide beyond the sd shell. Gamma-ray singles and coincidence spectra have been determined for the decays of {sup 64,66}Mn to levels of {sup 64,66}Fe, revealing strong deformation and vanishing of the N=40 subshell in the Fe isotopes. {copyright} {ital 1998 American Institute of Physics.}
1998-12-01
Decay of very neutron-rich Mn nuclides and vanishing of the N=40 subshell closure in "6"6Fe
International Nuclear Information System (INIS)
The use of chemically selective laser ionization combined with beta-delayed neutron counting at ISOLDE has permitted identification and half-life measurements for "6"1Mn up through "6"9Mn. The 14(4)-ms half life for "6"9Mn is one of the shortest determined for any nuclide beyond the sd shell. Gamma-ray singles and coincidence spectra have been determined for the decays of "6"4","6"6Mn to levels of "6"4","6"6Fe, revealing strong deformation and vanishing of the N=40 subshell in the Fe isotopes.
1998-12-21
Decay of Neutron-Rich Mn Nuclides and Deformation of Heavy Fe Isotopes
Energy Technology Data Exchange (ETDEWEB)
The use of chemically selective laser ionization combined with {beta} -delayed neutron counting at CERN/ISOLDE has permitted identification and half-life measurements for 623-ms {sup 61}Mn up through 14-ms {sup 69}Mn . The measured half-lives are found to be significantly longer near N=40 than the values calculated with a quasiparticle random-phase-approximation shell model. Gamma-ray singles and coincidence spectroscopy has been performed for {sup 64,66}Mn decays to levels of {sup 64,66}Fe , revealing a significant drop in the energy of the first 2{sup +} state in these nuclides that suggests an unanticipated increase in collectivity near N=40 . {copyright} {ital 1999} {ital The American Physical Society }
1999-02-01
Decay of Neutron-Rich Mn Nuclides and Deformation of Heavy Fe Isotopes
International Nuclear Information System (INIS)
The use of chemically selective laser ionization combined with #beta# -delayed neutron counting at CERN/ISOLDE has permitted identification and half-life measurements for 623-ms "6"1Mn up through 14-ms "6"9Mn . The measured half-lives are found to be significantly longer near N=40 than the values calculated with a quasiparticle random-phase-approximation shell model. Gamma-ray singles and coincidence spectroscopy has been performed for "6"4","6"6Mn decays to levels of "6"4","6"6Fe , revealing a significant drop in the energy of the first 2"+ state in these nuclides that suggests an unanticipated increase in collectivity near N=40 . copyright 1999 The American Physical Society.
1999-02-01
DBR laser with nondynamic plasma grating formed by focused ion beam implanted dopants
Energy Technology Data Exchange (ETDEWEB)
A static plasma grating has been demonstrated experimentally in a large optical cavity FIB-DBR GaAlAs/GaAs laser diode. The grating is formed by implanting stripes of dopants with a focused ion beam (FIB). The dopants ionize to form periodic fluctuations in the carrier concentration which, through the Kramers-Kronig relations, form an index grating. A model of the grating strength for optimization of the laser design is developed and presented here. The computed results show that /kappa/ can be increased by more than an order of magnitude over the 15 cm/sup -1/ experimentally. Therefore, FIB-DBR (or -DFB) lasers with performance comparable to that of conventional DBR (or DFB) lasers can be expected.
1989-06-01
DBR laser with nondynamic plasma grating formed by focused ion beam implanted dopants
International Nuclear Information System (INIS)
A static plasma grating has been demonstrated experimentally in a large optical cavity FIB-DBR GaAlAs/GaAs laser diode. The grating is formed by implanting stripes of dopants with a focused ion beam (FIB). The dopants ionize to form periodic fluctuations in the carrier concentration which, through the Kramers-Kronig relations, form an index grating. A model of the grating strength for optimization of the laser design is developed and presented here. The computed results show that #kappa# can be increased by more than an order of magnitude over the 15 cm"-"1 experimentally. Therefore, FIB-DBR (or -DFB) lasers with performance comparable to that of conventional DBR (or DFB) lasers can be expected.
International Nuclear Information System (INIS)
The activity of tyrosine aminotransferase (TAT) in the liver of mice subjected simultaneously to ionizing radiation and to local inflammatory process showed in the first 24 hours of the experiment statistically significant changes resulting from summation of the harmful effects of both factors. In the second 24-hour period an evident tendency was observed for return of a normal circadian rhythm of the enzyme. This points to presence of an endogenous mechanism of suppression of the manifestations of significant desynchronization of the circadian rhythm. The paper contains also a trial of mathematical analysis of changes in TAT activity in the circadian rhythm, a description and analysis or the suppression process, qualitative and quantitative determination of the phenomenon of cumulation of the effects of powerful stress factors acting on the animal organism. The obtained results were compared with the results of investigations of TAT activity changes obtained in ...
1980-01-01
Complexing of vanadium(3) with chromotropic acid derivatives
International Nuclear Information System (INIS)
A spectrophotometric study has been made of the complex formation of vanadium (3) with arsenazo(1), arsenazo(3) and some monosubstituted derivatives of chromotropic acid and sulphanylamides. In acid medium vanadium (3) reacts with each of these reagents to produce a 1:1 complex. Optimum conditions of the complex formation was found. The effect of H"+ on the complex formation of vanadium (3) with chromotropic acid derivatives was established. It was found by the graphical method that the formation of the complex is accompanied by the elimination of one proton. Patterns were found of the influence of the nature of substituents in the organic compound on the ionization constants of acid groups and stability of complexes. Molar extinction coefficients, equilibrium constants of the formation reactions and instability constants for the complexes were calculated. The structure of complexes was suggested. Similar behaviour of all the reagents was established in the complex ...
1976-01-01
Compact Single-Stage Fuel Processor for PEM Fuel Cells. Final report
Energy Technology Data Exchange (ETDEWEB)
Based on observations during the steam reforming of ethanol, the authors conclude that carbon was forming in the steam generator due to the thermal decomposition of ethanol. Since ethanol is being thermally decomposed, they were operating the steam generator at too high of a temperature. The thermal degradation of ethanol was confirmed by using a GC with a flame ionization detector. They observed trace amounts of additional hydrocarbons other than methane in the effluent which we assume maybe ethane and ethylene. We identified the operating conditions that allowed us to steam reform ethanol for an acceptable amount of time. These conditions were a steam temperature of 200 C and a wall temperature of 400 C at the center of the reactor. The calculated ratios of CO{sub 2}/CO indicate that we can lower the potential for carbon deposition from the Boudouard further by reducing the pressure.
2000-01-01
British Library Electronic Table of Contents (United Kingdom)
The atmospheric processing by ozone of peptide-containing mixed particles was investigated as proxies for biogenic and sea spray primary organic aerosol. Reactions were performed in a flow reactor and particle composition was monitored by photoelectron resonance capture ionization aerosol mass spectrometry. Mixed particles containing dipeptides in a saturated organic matrix of stearic and palmitic acids showed no reaction under ozonolysis at exposure levels of 2.5???10?4?atm s O3. However reactions of mixed particles of a dipeptide (Leu-Leu) in an unsaturated matrix (oleic acid) under the same conditions resulted in a rapid loss of the peptide ion signal, as well as the carrier matrix, and appearance of a number of ion signals corresponding to secondary products. High molecular weight imid...
2009-01-01
International Nuclear Information System (INIS)
The stages of processes leading to radiation damage are studied, as well as, the direct and indirect mechanics of its production. The radiation effects on nucleic acid and protein macro moleculas are treated. The physical and chemical factors that modify radiosensibility are analysed, in particular the oxygen effects, the sensibilization by analogues of nitrogen bases, post-effects, chemical protection and inherent cell factors. Consideration is given to restoration processes by excision of injured fragments, the bloching of the excision restoration processes, the restoration of lesions caused by ionizing radiations and to the restoration by genetic recombination. Referring to somatic effects of radiation, the early ones and the acute syndrome of radiation are discussed. The difference of radiosensibility observed in mammalian cells and main observable alterations in tissues and organs are commented. Referring to delayed radiation effects, carcinogeneses, ...
1976-01-01
Biological effects of electromagnetic radiation in the microwave range
Energy Technology Data Exchange (ETDEWEB)
The book examines current experimental and clinical knowledge concerning the biological and biophysical effects of electromagnetic radiation, particularly that in the microwave range. The biophysical bases of the interaction of electromagnetic radiation with matter are reviewed with emphasis on biological systems, and the effects of radiation on critical biological systems, including the nervous, reproductive, visual and blood-forming systems are compared. Data concerning the lethal effects of nonionizing radiation is presented and characteristics of the effects of electromagnetic radiation on the whole mammalian organisms are examined. Various reactions of the neuroendocrine system to electromagnetic radiation are described, with particular attention given to the adrenal system, and the combined effects of ionizing and microwave radiation in the flight environment are discussed. Results are also presented of a series of animal experiments on the quantitative ...
1980-01-01
Basic mechanisms of radiation effects in the natural space radiation environment
Energy Technology Data Exchange (ETDEWEB)
Four general topics are covered in respect to the natural space radiation environment: (1) particles trapped by the earth`s magnetic field, (2) cosmic rays, (3) radiation environment inside a spacecraft, (4) laboratory radiation sources. The interaction of radiation with materials is described by ionization effects and displacement effects. Total-dose effects on MOS devices is discussed with respect to: measurement techniques, electron-hole yield, hole transport, oxide traps, interface traps, border traps, device properties, case studies and special concerns for commercial devices. Other device types considered for total-dose effects are SOI devices and nitrided oxide devices. Lastly, single event phenomena are discussed with respect to charge collection mechanisms and hard errors. (GHH)
1994-06-01
Energy Technology Data Exchange (ETDEWEB)
A detector head for in situ inspection of irradiated nuclear fuel assemblies submerged in a water-filled nuclear fuel storage pond. The detector head includes two parallel arms which extend from a housing and which are spaced apart so as to be positionable on opposite sides of a submerged fuel assembly. Each arm includes an ionization chamber and two fission chambers. One fission chamber in each arm is enclosed in a cadmium shield and the other fission chamber is unshielded. The ratio of the outputs of the shielded and unshielded fission chambers is used to determine the boron content of the pond water. Correcting for the boron content, the neutron flux and gamma ray intensity are then used to verify the declared exposure, cooling time and fissile material content of the irradiated fuel assembly.
1985-04-09
Apheresis affects bone and mineral metabolism
British Library Electronic Table of Contents (United Kingdom)
Background: Apheresis is a procedure to selectively obtain blood components. For the collection process citrate is routinely used. It inhibits coagulation by binding to ionized calcium and leads to metabolic alkalosis. Objective: Whether regular apheresis affects bone and mineral metabolism is unknown. The intention of this study was to investigate 1) the acute effects of apheresis on acid-base balance, bone and mineral metabolism and 2) to compare bone mineral density (BMD) at the lumbar spine and hip of donors to matched control subjects. Design: In this open, observational, single-center, cross-sectional study we enrolled 102 regular plasma and thrombocyte donors to pursue objective 1) and compared those to 102 matched controls (CTR) for objective 2). Results: Platelet donation led to s...
2010-01-01
An integrating dosimeter for pulsed radiation
A Pulsed Radiation Dosimetry System designed to measure radiation produced by particle accelerators is described. The problems associated with total-dose measurement of irregular shaped pulses of ionizing radiation have been simplified. The system responds to extremely narrow pulses of charged particles or X-rays using a pin diode as the detector. Direct readout of dose in rads (Si) is displayed on a 3-1/2 digit digital panel meter. The system will operate in either the multiple-pulse or single-pulse mode. The multiple-pulse mode would be useful in monitoring or tuning a linear accelerator. In the single-pulse mode the system will automatically display total dose of a transient event in real time and hold that measurement indefinitely or until the next measurement is made. The system features an automatic reset in either mode.
1983-12-01
Alpha-particle dose distribution effects at the cellular level
International Nuclear Information System (INIS)
Ionizing radiations that differ in number, size, and distribution of energy deposition events might be expected to cause different effects for the same absorbed dose. Furthermore, microdosimetry calculations suggest that large variations in biological effectiveness might be expected for internally deposited alpha-emitting radionuclides for the same absorbed dose, depending upon the specific activity and spatial distribution of the sources in tissue. The study described in this article was designed to demonstrate these phenomena in vitro. Cultured Chinese hamster ovary (CHO-K1 BH4) cells were exposed in vitro to inert, insoluble ceramic microspheres in zirconium dioxide labeled with "2"3"9Pu. The average exit energy of the 5.15 MeV alpha particle was calculated to be 4.3 MeV. Exposure times varied from four to seven hours to achieve the desired dose level.
1985-02-01
Advanced oxidation process based on ozone/electron beam irradiation for treating groundwater
International Nuclear Information System (INIS)
There are several methods of generating OH free radicals from ozone and/or hydrogen peroxide and ultraviolet light. They all have in common that the OH free radicals originate in one single source only whereas in the combination of ozone with ionizing radiation two simultaneous working sources for the OH free radicals exist. The resulting higher OH free radical concentration makes this process especially apt for the remediation of low level contaminated groundwater as for example trichloroethylene (TCE) contamination in the sub-ppm range. A cost comparison between O_3/UV and O_3/electron beam for remediation of a groundwater contaminated with 100 ppb TCE indicated that for a throughput of about 5 million gallons/day the O_3/electron beam process is more cost-effective. (authors).
Energy Technology Data Exchange (ETDEWEB)
The /sup 252/Cf-source-driven noise analysis method determines the subcriticality of a system containing fissionable material from the ratio of cross power spectral densities between the detectors that detect particles from the fission process and between these detectors and an ionization chamber containing a spontaneously fissioning neutron source which provides neutrons to induce fission in the system. This method has two advantages: (1) a calibration is not required and thus subcriticality can be determined from measurements only on the subcritical system of interest, and (2) the subcriticality is independent of the type of detector or its efficiency. These properties of this technique are illustrated by measurements.
1984-01-01
A.C.R.O. activity report 2005; ACRO rapport d'activite 2005
Energy Technology Data Exchange (ETDEWEB)
The A.C.R.O. is an association law 1901 declared at the Calvados prefecture at the date of 14. october 1986 and registered as environment protection. It was created, by more than 900 persons, in the months following the Chernobylsk accident in reaction to a lack of information and means of independent radiation monitoring. The particularity of the association is to own a laboratory of radioactivity analysis. Since the end of the nineties, the concerns include the natural sources of irradiation as the radon and apply to the consequences, out of nuclear industry, of the use of ionizing radiation or radioactive matter. On this last point, the affair of the orphan industrial site Bayard at Saint-Nicolas-d'Aliermont, massively contaminated by radium-226 devoted to the fabrication of alarm clocks, and the appearance of exemption threshold in the European law are elements at the origin of this evolution. (N.C.)
2006-07-01
International Nuclear Information System (INIS)
The widespread use of building materials with relatively high radium concentrations may increase population exposure. A method is presented for measuring effective diffusion coefficients and exhalation rates of radon from such materials. Equations for use in the experimental determination of these values are obtained theoretically. The experimental set-up consists of a container which is hermetically sealed to a slab of the building material. Nitrogen is blown through the container and then through an ionization chamber which is connected to an electrometer and X-Y plotter, and the radon concentration is measured continuously. Exhalation rates of radon from some major building materials measured by this method will be used as reference levels. The method can also be used to determine other properties such as porosity. (author).
A Versatile Evaporative Cooling System Designed for Use in an Elementary Particle Detector
British Library Electronic Table of Contents (United Kingdom)
An evaporative cooling system developed for operation and qualification testing of silicon pixel and microstrip detectors for the inner tracking detector of the CERN ATLAS spectrometer is described. Silicon detector substrates must be continuously operated between 0 and ???7?C in the high radiation environment near the circulating beams at the CERN Large Hadron Collider (LHC). This requirement imposes unusual constraints on the cooling system and has led to the choice of perfluoro-n-propane (C3F8) refrigerant, which combines good chemical stability under ionizing radiation with high dielectric strength and nonflammability. Since the silicon detectors must also be of extremely light construction to minimize undesirable physics background, coolant tubes are of thin (200 ?m) aluminum wall, wh...
2007-01-01
The role of 3D Helical CT in the reconstructive treatment of maxillofacial cancers
International Nuclear Information System (INIS)
Purpose of this work is to investigate the role of Helical CT and the usefulness of three-dimensional (3D) imaging for pre-operative planning and follow-up of reconstructive maxillofacial surgery with alloplastic material in neoplastic disease involving this region. From 1996 to 1999 eleven patients were examined with Helical CT and 3D images for planning of maxillofacial plastic and reconstructive surgery for advanced cancer of this anatomically complex region. A 3D-modulated titanium mesh (100%) or micro nets was used to rebuild the anterior surface of maxillary bone and the orbital floor. The mesh was cut to the appropriate size and shape and curved where necessary. Within the residual sinusal cavity a siliconed filling was used surmounting an acrylic prosthesis with dental arch to rebuild the palate. A rehydrated bovine pericardium was affixed and moduled on the borders in two cases only. Three-dimensionally reconstructed CT images were obtained preoperatively and at least 6 months ...
2000-12-01
Energy Technology Data Exchange (ETDEWEB)
Minimally invasive thermotherapies for focal tissue destruction on the basis of laser-, microwave-, focused ultrasound-, or cryogeninduced changes of tissue temperature represent an alternative to surgical tissue ablation, particularly in the treatment of tumors. The thermotherapy modalities listed necessitate indirect guidance and monitoring, since they often do not lend themselves to immediate visual control. In the brain, in head and neck tumors, in the liver, and in the prostate, MRI reliably and accurately delineates both the positions of interstitial thermotherapy applicators and - in contrast-enhanced, T1-weighted images - the perfusion defects in tissue necrosis induced by thermotherapy. The transfer of results of in-vitro and in-vivo model studies to assess interstitial temperature and lesion development during thermotherapy to the actual treatment of patients, however, is still in an initial phase. Further development of both rapid MRI sequences and MRI ...
1998-03-01
Investigation of dominant loss mechanisms in low-temperature polymer electrolyte membrane fuel cells
Energy Technology Data Exchange (ETDEWEB)
This thesis deals with the analysis of dominant loss mechanisms in direct methanol fuel cells (DMFC) and hydrogen fed polymer electrolyte membrane fuel cells (PEFC) by means of experimental characterization and modeling work. Due to different fuels used in these two fuel cell types, the dominant loss mechanisms are different in their nature. All in-situ characterization techniques that are used in this work are based on a novel test fuel cell with embedded reference electrodes. The first part of this work presents a new concept for realizing a reference electrode configuration in a polymer electrolyte membrane fuel cell by means of laser ablation. The laser beam is used to evaporate a small gap into the electrode surface of a catalyst coated membrane (CCM) to isolate the reference electrode from the working/counter electrode (WE/CE). This method enables the simultaneous ablation of the electrodes on both sides of the CCM because the membrane is ...
2010-07-01
Tritium release from lithium orthosilicate pebbles deposited with palladium
International Nuclear Information System (INIS)
Full text of publication follows: Slightly over-stoichiometric lithium orthosilicate pebbles have been selected as one optional breeder material for the European Helium Cooled Pebble Bed (HCPB) blanket. This material has been developed in collaboration of Research Center Karlsruhe and the Schott Glass, Mainz. The lithium orthosilicate pebbles are fabricated from lithium hydroxide and silica by a melting and spraying method in a semi-industrial scale facility. Lithium hydroxide was selected as the precursor since enriched lithium hydroxide is commercially available. The lithium orthosilicate pebbles produced by the process contains oxide phases besides orthosilicate, but it was also found that the oxide phases can be decomposed by annealing at high temperatures. The lithium orthosilicate pebbles produced in this way possesses satisfactory pebble characteristics. Therefore, the authors performed out-of-pile annealing tests using the lithium orthosilicate pebbles irradiated in a research ...
2007-12-10
International Nuclear Information System (INIS)
Track analysis of medium energy #alpha# particle trajectories recorded in fine grain nuclear emulsion submitted to specific intensifying treatments led to the observation of strong ionizing events (SIE) sticking out of the primary's track core. Preliminary determinations showed that the number of SIEs increases with the primary's energy, and that their production is of more than one order of magnitude higher than the number of Rutherford recoils. The presence of SIEs on monoenergetic #alpha# tracks also has a significant influence on the measured range distribution, which, expressed in terms of energy loss, results in a mean contribution to the total energy loss of far reaching (SIEs (radial spread >= 0.458 #mu#m) of proportional 25 keV per 13.6 MeV #alpha# particle, instead of 0.75 keV in the case where only the Rutherford interactions are taken into account. Measurements carried out in detectors enriched with gelatin indicate an increase in the number of SIEs ...
Selection and design of ion sources for use at the Holifield radioactive ion beam facility
Energy Technology Data Exchange (ETDEWEB)
The Holifield Radioactive Ion Beam Facility now under construction at the Oak Ridge National Laboratory will use the 25 MV tandem accelerator for the acceleration of radioactive ion beams to energies appropriate for research in nuclear physics; negative ion beams are, therefore, required for injection into the tandem accelerator. Because charge exchange is an efficient means for converting initially positive ion beams to negative ion beams, both positive and negative ion sources are viable options for use at the facility. The choice of the type of ion source will depend on the overall efficiency for generating the radioactive species of interest. Although direct-extraction negative ion sources are clearly desirable, the ion formation efficiencies are often too low for practical consideration; for this situation, positive ion sources, in combination with charge exchange, are the logical choice. The high-temperature version of the CERN-ISOLDE positive ion source has been selected and a ...
1994-06-01
Relative correlation of Jet-REMPI monitoring with adsorption tube sampling followed by TDS-CIS-GC/MS
Energy Technology Data Exchange (ETDEWEB)
During earlier work rapid and highly sensitive Jet-REMPI (resonance-enhanced multiphoton ionization) mass spectrometry was applied for monitoring the effluent from thermal treatment of a filter dust during a de novo test under laboratory conditions. The sample, from ESP-Field 2 of an iron ore sintering plant, was already loaded with dioxins ({sigma}PCDD/F = 132 ng/g), their precursors (PCBz, PCPh) and other products of incomplete combustion. Heating filter dust in a temperature window 200-350 C under a flow of air results in further formation of these pollutants. As described elsewhere, on-line detection was mostly carried out using a non-selective ionization mode, to measure a wide range of compounds simultaneously. The changes of output suggest that the reaction products increase in chlorination level with time. Another explanation is that higherchlorinated compounds appear later as a consequence of lower volatility and stronger adsorption. ...
2004-09-15
International Nuclear Information System (INIS)
After five years of implantation of a program for classification and signalling of restricted areas in the IPEN-CNEN-SP, we noticed that the applied measures of radio protection contributed for the improvement of the system of occupational radiological protection, promoting an improvement in the security of the workers, towards the planning in the execution of the activities involving the use of sources of ionizing radiation. Later, during the implantation of this program, the service of occupational radiological protection, there was great difficulty to conciliate its necessities in terms of security signalling, face the absence of existing standardisation in the country for the minimum disposals on the subject in question. Nowadays there are different interpretations of the specific criteria and many effective normative documents that exist in the country. This work presents as proposal the elaboration of a technical guide whose objective is to display the ...
Particle simulation of edge pedestal formation and plasma rotation dynamics
International Nuclear Information System (INIS)
Gyrokinetic particle simulation of edge pedestal formation and plasma rotation dynamics will be presented, and compared with experimental observations. Realistic tokamak edge geometry is used which include separatrix/X-point and material wall from EFIT g-eqdsk data. In order to handle adequately the spatially inhomogeneous electric potential in the scrape-off region, the full-f electron technique is used, in addition to the full-f ions. Monte Carlo neutral particles with wall recycling coefficient will be included self-consistently with the plasma kinetics. Ion-ion Coulomb collisions will be particle, momentum and energy conserving. Energy source for the pedestal and scrape-off plasmas is the heat flow from the core plasma, and the particle source is the ionization of the neutral atoms which are either wall recycled and/or gas puffed. The simulation will be self-consistent with the first principles nonlinear neoclassical and (electrostatic so far) turbulence ...
2007-03-26
Electron-beam-plasma ion source as source of negative fluorine
Energy Technology Data Exchange (ETDEWEB)
Radioactive ion beams (RIBs) of short-lived isotopes of fluorine are in demand for investigating astrophysical phenomena related to the hot CNO cycle and rp processes responsible for stellar nucleosynthesis. Since negative ion beams are required for injection into tandem electrostatic accelerators, such as the 25 MV tandem accelerator used for post acceleration of RIBs for the Holifield Radioactive Ion Beam Facility (HRIBF) research program at the Oak Ridge National Laboratory (ORNL), efficient, direct-formation F{sup -} ion sources are highly desirable for RIB applications involving this type of post-accelerator. We have conceived and evaluated a direct extraction F{sup -} source for potential RIB applications which is predicated on the reverse polarity operation of a positive electron-beam-plasma target/ion source (EBPTIS) while simultaneously feeding fluorine rich compounds and Cs vapor into the source. The source is found to operate in two separately distinct temperature regimes ...
1997-11-01
Deformation change in light iridium nuclei from laser spectroscopy
International Nuclear Information System (INIS)
Laser spectroscopy measurements have been performed on neutron-deficient and stable Ir isotopes using the COMPLIS experimental setup installed at ISOLDE-CERN. The radioactive Ir atoms were obtained from successive decays of a mass-separated Hg beam deposited onto a carbon substrate after deceleration to 1kV and subsequently laser desorbed. A three-color, two-step resonant scheme was used to selectively ionize the desorbed Ir atoms. The hyperfine structure (HFS) and isotope shift (IS) of the first transition of the ionization path 5d"76s"2"4F_9_/_2#->#5d"76s6p"6F_1_1_/_2 at 351.5nm were measured for "1"8"2"-"1"8"9Ir, "1"8"6Ir"m and the stable "1"9"1","1"9"3Ir. The nuclear magnetic moments #mu#_I and the spectroscopic quadrupole moments Q_s were obtained from the HFS spectra and the change of the mean square charge radii from the IS measurements. The sign of #mu#_I was experimentally determined for the first time for the masses 182#=#+0.2 for ...
2006-12-01
International Nuclear Information System (INIS)
Full text: DNA rearrangement events leading to chromosomal aberrations are central to ionizing radiation-induced cell death. Although DNA double-strand breaks are probably the lesion that initiates formation of chromosomal aberrations, little is understood about the molecular mechanisms that generate and modulate DNA rearrangement. Examination of the sequences that flank sites of DNA rearrangement may provide information regarding the processes and enzymes involved in rearrangement events. Accordingly, we developed a method using inverse PCR that allows the detection and sequencing of putative radiation-induced DNA rearrangements in defined regions of the human genome. The method can detect single copies of a rearrangement event that has occurred in a particular region of the genome and, therefore, DNA rearrangement detection does not require survival and continued multiplication of the affected cell. Ionizing radiation-induced DNA ...
2003-08-17
Energy Technology Data Exchange (ETDEWEB)
The object and the purpose of the present work was to develop, to assemble and to start running a new TOF (time of flight) mass spectrometer for imaging SNMS analytic which is optimized for the analysis of highly molecular secondary ions. The most important purpose was the characterization of the TOF mass spectrometer. The obtained mass spectra of indium, tantalum and silver clusters reflect the excellent properties of the TOF mass spectrometer for the detection of large clusters with good detection efficiency up to masses of 16000 amu. The possibility of the deflection of selected saturated atom and cluster peaks serves for further improvement of the detection efficiency for large molecules. The accessible mass resolution was determined to be of the order of m/{delta}m=1000 in the high mass region. Numerous measurements were carried out to characterize the useful yield of this spectrometer. For a best possible adaptation of the TOF mass spectrometer for the detection of highly ...
2006-12-21
Benzene molecule is destroyed by ultraviolet and soft X-rays in circumstellar environment
International Nuclear Information System (INIS)
Benzene molecules , present in the proto-planetary nebula CRL 618, are ionized and dissociated by ultraviolet (UV) and X-ray photons originated from the hot central star and by its fast wind. Ionic species and free radicals produced by these processes can lead to the formation of new organic molecules. The aim of this work is to study the photoionization and photodissociation processes of the benzene molecule, using synchrotron radiation and time-of-flight mass spectrometry. Mass spectra were recorded at different energies corresponding to the vacuum UV (21.21 eV) and soft X-ray (282-310 eV) spectral regions. The production of ions from the benzene dissociative photoionization is here quantified, indicating that C_6H_6 is more efficiently fragmented by soft X-ray than UV radiation, where 50% of the ionized benzene molecules survive to UV dissociation while only about 4% resist to C-rays. Partial ion yields of H and small hydrocarbons, such as ...
Energy Technology Data Exchange (ETDEWEB)
The theoretical analysis of a partially-ionized hydrogen gas flow (gas temperatures of approximately 10,000 to 20,000 K) through a particular class of magnetohydrodynamic (MHD) generators and the preliminary design of these MHD generators as open cycle, electric power supplies are performed. Analysis of the gas flow through these ultra-high temperature MHD generators requires a coupled gas dynamics/radiative heat transfer solution. Gas dynamics are modeled by a set of quasi-one-dimensional, nonlinear differential equations which account for friction, convective and radiative heat transfer and the interaction between the ionized gas and applied magnetic field. Radiative heat transfer is modeled using non-gray, absorbing-emitting two- and three-dimensional P-1 approximations which permit an arbitrary variation of the spectral absorption coefficient with frequency. Gas dynamics and radiative heat transfer are coupled through the energy equation, ...
1990-01-01
International Nuclear Information System (INIS)
The purpose of this study is to evaluate the accuracy of dose calculations by three algorithms. Depth dose, OPF (Output Factor) and dose profiles were measured in a heterogeneous phantom. These values were also calculated by three algorithms of the Batho power law (BPL), Equivalent-Tissue Air Ratio (ETAR) and Convolution superposition (CS). The data were obtained for 4, 6 and 10 MV photon beams with a linear accelerator (Varian 21EX). Field size ranged from 3 x 3 cm"2 to 10 x 10 cm"2. Dose profiles of beam penumbra were also measured by a 0.125 ml ionization chamber at the point of 8, 13 and 18 cm from the surface of the phantom at intervals of 1 mm. Differences between measured and calculated depth doses were within 2% in BPL and CS, but depth doses were overestimated in ETAR. OPFs were also overestimated with the error of more than 4% in ETAR. Absorbed dose calculated by CS were in agreement with the values measured by the ionization chamber. ...
2004-12-01
International Nuclear Information System (INIS)
Purpose: Radiotherapy (RT) has been the predominant local treatment for Ewing's sarcoma of bone at the University of Florida. Twice-daily hyperfractionated RT was initiated in 1982 to improve local control and functional outcome. This retrospective review compares the results of once-daily vs. twice-daily RT in patients with primary Ewing's sarcoma of an extremity, with emphasis on functional outcome. Methods and Materials: Between June 1971 and January 1990, 37 patients were treated at the University of Florida for nonmetastatic Ewing's sarcoma of bone with a primary lesion in an extremity. Three patients underwent amputation. Of 34 patients treated with RT, 31 had RT alone and 3 had a combination of RT and local excision. Before 1982, 14 patients received once-daily RT; since 1982, 17 patients have received twice-daily RT. Doses of once-daily RT varied from 47 to 61 Gy at 1.8-2 Gy per fraction. Doses of twice-daily RT varied, depending on the response of the soft-tissue component of ...
1996-07-01
Energy Technology Data Exchange (ETDEWEB)
Fourier transform infrared (FTIR) difference spectra have been obtained for the bR----K, bR----L, and bR----M photoreactions in bacteriorhodopsin mutants in which Asp residues 85, 96, 115, and 212 have been replaced by Asn and by Glu. Difference peaks that had previously been attributed to Asp COOH groups on the basis of isotopic labeling were absent or shifted in these mutants. In general, each COOH peak was affected strongly by mutation at only one of the four residues. Thus, it was possible to assign each peak tentatively to a particular Asp. From these assignments, a model for the proton-pumping mechanism of bR is derived, which features proton transfers among Asp-85, -96, and -212, the chromophore Schiff base, and other ionizable groups within the protein. The model can explain the observed COOH peaks in the FTIR difference spectra of bR photointermediates and could also account for other recent results on site-directed mutants of bR.
1988-11-15
Energy Technology Data Exchange (ETDEWEB)
As part of a U.S. multi-regional pilot study conducted by the six Centers for Radiological Physics, 12-mm-diameter by 0.4-mm-thick CaSO/sub 4/:Dy Teflon-embedded discs were evaluated and used to measure patient entrance exposure on 60 average patients at 12 clinical centers. The discs were found to have adequate sensitivity, reproducibility and linearity up to 69.7 microC kg-1 (270 mR). The minimum measurable exposure was estimated as 0.4 microC kg-1 (1.5 mR). All responses were corrected for energy dependence, which varied +/- 20% from 1.7 to 6.5 mm Al half-value layer. Patient entrance exposure values ranged from 1.3 to 28 microC kg-1 (5 to 110 mR), with a median value of 5.2 microC kg-1 (20 mR). This value agreed with exposure measurements made on the chest radiography equipment using an ionization chamber and a phantom which simulated an average patient, and with published Nationwide Evaluation of X-Ray Trends (NEXT) data for the same period.
1987-12-01
Upper bound for a three-photon excitation cross section in atomic argon in the ultraviolet regime
Energy Technology Data Exchange (ETDEWEB)
A scheme of evaluating a generalized three-photon excitation cross section sigma/sub (3)/ in neutral atomic argon at 3144.67 A is outlined. Three photons at this wavelength can excite the neutral argon atoms from the ground 3p/sup 6/ /sup 1/S/sub 0/ state to the 3p/sup 5/4s'(1/2)/sub 1//sup 0/ state. The fourth photon will ionize the argon atoms. Assuming linear polarization of the incident laser radiation, contributions from several channels in various energy-level schemes are summed in the evaluation of the transition probability. For a laser linewidth of ..delta..lambda/sub L/ = 1 A, our maximum numerical value of the computed result for the three-photon excitation cross section is sigma/sub (3)/ = 1.414 x 10/sup -80/ cm/sup 6/ s/sup 2/. .AE
1989-04-15
The effect of irradiation on packaging materials
International Nuclear Information System (INIS)
Ionizing radiation, mainly in the form of #gamma#-rays from the radioisotope cobalt 60, is being used increasingly for the inactivation of contaminants in cosmetic and toiletry preparations. The treatment is applied to the product in its final pack, and therefore, it is important to recognize that the properties of the packaging materials could be affected, particularly if high radiation doses are used. The stability of a wide range of materials is discussed. The nature and extent of chemical and physical changes in plastics very much depends on the presence of antioxidants and other additives, and on the environmental conditions during irradiation. Some useful information is available from research into the use of radiation for the preservation of food - many films and laminates have been cleared for use in the United States. The low radiation doses used for the control of contaminants in cosmetic products are quite unlikely to cause changes in packaging materials ...
The distribution of Lyman-limit absorption systems during and after reionization
Lyman-limit absorption systems can play many important roles during and after cosmological reionization. Unfortunately, due to the prohibitively large dynamic range required, it is impossible to self-consistently include these systems in cosmological simulations. Using fast and versatile semi-numeric simulations, we systematically explore the spatial distribution of absorption systems during and following reionization. We self-calibrate the resulting number of absorbers to the mean free path (mfp) of the ionizing ultraviolet background (UVB), and present results at a given mfp and neutral hydrogen fraction. We use a simple optical depth criterion to identify the locations of absorbers. Our approach is fairly robust to uncertainties such as missing subgrid structure. Unlike at lower redshifts where the UVB is relatively uniform, at higher redshifts the fluctuations in the UVB and the HII morphology of reionization can drive the large-scale distribution of absorption ...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
The present study discusses the contribution of the adoption of more rigorous and objective criteria to the selection and analysis of information sources, leading to more scientific rigour when registering phytotherapic drugs. To this end, it is herein proposed the adoption of a previously tested and acknowledged methodology, namely the Systematic Revision, as a standard for phytotherapic drug analyses. In order to show differences brought about by the Systematic Revision during the registration procedures of phytotherapic drugs, the case of the Maytenus ilicifolia (known popularly in Brazil as 'espinheira-santa') is presented. As it is well known, the use of ionizing radiation is expanding, especially in medicine and pharmacy. Therefore, gamma radiation was applied to the microbiological quality control of phytotherapic matrices. Results indicated a positive contribution of Systematic Revision to the registration procedures of phytotherapic ...
2006-07-01
Subcritical measurements using the /sup 252/Cf source-driven neutron noise analysis method
Energy Technology Data Exchange (ETDEWEB)
This paper describes recent measurements of the subcritical neutron multiplication factor using the /sup 252/Cf source-driven neutron noise analysis method. This work was supported by a program of collaboration between the United States Department of Energy and the Power Reactor and Nuclear Fuel Development Corporation of Japan related to the development of fast breeder technology. The experiment reported consists of a configuration of two interacting tanks of uranyl nitrate aqueous solution with different uranium concentrations in each tank. The /sup 252/Cf-source-driven neutron noise analysis method obtains the subcriticality from the signals of three detectors: the first, a parallel plate ionization chamber with /sup 252/Cf electroplated on one of its plates that is located in or near the system containing the fissile material, and produces an electrical pulse for every spontaneous fission that occurs and thereby serves as a timed source of fission neutrons; and ...
1985-01-01
Selective emitter using porous silicon for crystalline silicon solar cells
Energy Technology Data Exchange (ETDEWEB)
This study is devoted to the formation of high-low-level-doped selective emitter for crystalline silicon solar cells for photovoltaic application. We report here the formation of porous silicon under chemical reaction condition. The chemical mixture containing hydrofluoric and nitric acid, with de-ionized water, was used to make porous on the half of the silicon surface of size 125 x 125 cm. Porous and non-porous areas each share half of the whole silicon surface. H{sub 3}PO{sub 4}:methanol gives the best deposited layer with acceptable adherence and uniformity on the non-porous and porous areas of the silicon surface to get high- and low-level-doped regions. The volume concentration of H{sub 3}PO{sub 4} does not exceed 10% of the total volume emulsion. Phosphoric acid was used as an n-type doping source to make emitter for silicon solar cells. The measured emitter sheet resistances at the high- and low-level-doped regions were 30-35 and 97-474 ...
2009-06-15
Energy Technology Data Exchange (ETDEWEB)
Poly(methyl methacrylate), PMMA, Acrigel, a Brazilian polymer, is used in the manufacture of medical supplies sterelizable by ionizing radiation. However, when PMMA is gamma-irradiated it undergoes main chain scissions, which promote molecular degradation causing reduction in its mechanical properties. Therefore, radiolytic of PMMA is important for it to become commercially radiosterizable. In this work some commercial additives, originally used in photo-and thermo-oxidate stabilization of polymers, were tested. Only two additives, type HALS (Hindered Amine Light Stabilizer), denoted Scavenger, showed a good protective quality. The investigation of radiation-induced main scissions was carried out by viscosimetric method. The most effective additive, added to the polymer system at 0.3 w/w%, promotes a great molecular radioprotection of 93%. That means a reduction of G-value (scissions/100 eV) from 0.611 to 0.053. In addition, the glassy transition temperature (T{sub ...
2000-04-01
Radiation-induced reduction of ditetrazolium salt in aqueous solutions
Energy Technology Data Exchange (ETDEWEB)
Color formation in aqueous solutions of the ditetrazolium salt blue tetrazolium (BT{sup 2+}) in the absence or presence of oxygen is a complex radiation chemical reaction. The final stable product is the poorly soluble diformazan violet to blue pigment having a broad spectral absorption band ({lambda}{sub max}=552 nm). The reaction of BT{sup 2+} with the hydrated electron proceeds by rapid reduction of BT{sup 2+} followed by protonation at the nitrogen closest to the unsubstituted phenyl group, via the two intermediate tetrazolinyl radicals shared by the ditetrazole ring nitrogens. The effect of solution pH, N{sub 2}O saturation, and the presence of the reducing agent dextrose are examined. The system serves as a radiochromic sensor and a dosimeter of ionizing radiations. Solutions of 5 mmol l{sup -1} BT{sup 2+} at pH 7.3 serve as dosimeters over an absorbed-dose range of approximately 0.2-6 kGy (dearated, with a range of 1-8 mmol l{sup -1} dextrose) and of about ...
2002-04-01
The work presented in part 1 of this study established that the sorption of anhydrous HX into dehydrated Na{sub 56}Y progresses through a sequence of steps involving HX ionization and charge separation, oxygen framework protonation, formation of {alpha}-cage confined cation-anion contact ion pairs, and proton solvation by HX. A logical extension, which is the subjected of this study, concerns the effect of extraframework alkali metal cation type (M = Li{sup +}, Na{sup +}, K{sup +}, Rb{sup +}, Cs{sup +}) on the sorption process. The question of the acidity of proton-loaded zeolites compared to Broensted acid zeolites is addressed by using probe reactions with weak bases like ethane and cyclopropane. Additional insight into these systems is also obtained from a quantitative comparison of the kinetic and thermodynamic activation parameters for the dehydrohalogenation of proton-loaded zeolites exemplified by (HX){sub 8}Na{sub 56}Y relative to the decationization ...
1990-10-18
Energy Technology Data Exchange (ETDEWEB)
An ignition device of the plasma jet type is disclosed. The device has a cylindrical cavity formed in insulating material with an electrode at one end. The other end of the cylindrical cavity is closed by a metal plate with a small orifice in the center which plate serves as a second electrode. An arc jumping between the first electrode and the orifice plate causes the formation of a highly-ionized plasma in the cavity which is ejected through the orifice into the engine cylinder area to ignite the main fuel mixture. Two improvements are disclosed to enhance the operation of the device and the length of the plasma plume. One improvement is a metal hydride ring which is inserted in the cavity next to the first electrode. During operation, the high temperature in the cavity and the highly excited nature of the plasma breaks down the metal hydride, liberating hydrogen which acts as an additional fuel to help plasma formation. A second improvement consists of a cavity ...
1985-01-15
Multiple Ion Exchange Column Tests for Technetium Removal from Hanford Tank Waste Supernate
Five cycles of loading, elution, and regeneration were performed to remove technetium from a Hanford waste sample retrieved from Tank 241-AW-101 using SuperLig 639 resin. The waste sample was diluted to 4.95 M Na plus and then was processed to remove 137Cs through dual ion exchange columns each containing 15 mL of SuperLig 644. To remove 99Tc, the cesium decontaminated solution was processed downwards through two ion exchange columns, each containing 12 mL of SuperLig 639 resin. The columns, designated as lead and lag, each had an inside diameter of 1.45 cm and a height of 30 cm. The columns were loaded in series, but were eluted and then regenerated separately. The average technetium loading for the cycles was 250 BV at 10 percent breakthrough. There was no significant difference in the loading performances among the five cycles. The percent removal of 99Tc was greater than 99.94 percent and the average decontamination factor (DF) was approximately 1.7 x 103. Approximately 99 percent ...
2004-02-27
Modelling discharges in electronegative gases
Energy Technology Data Exchange (ETDEWEB)
This paper builds on earlier work to give a consistent treatment of the positive column of discharges in electronegative gases covering the transition from collisionless to collisional. In particular it seeks to elucidate the conditions under which there is an ion-ion plasma core surrounded by an electron-ion plasma, and when there is not. The parameters which describe the processes of ionization, attachment, detachment and recombination are related to the central negative ion density relative to the electron density and, where appropriate, the size of the core. The use, by earlier workers, of the Boltzmann approximation to describe the negative ion distribution and to obtain ambipolar diffusion coefficients at higher pressures is shown not to be justified. This leads to the clarification of an inconsistency in the literature. Where possible, the work is related to other recent treatments of the same problem in order to begin to build a comprehensive picture of ...
1999-09-07
International Nuclear Information System (INIS)
A merged-beams electron-energy-loss technique is described, by which absolute cross sections can be measured for near-threshold electron-impact excitation of multipy charged ions. Results are reported here for absolute total electron-impact excitation cross sections for the O"5"+(2s#->#2p) transition from below threshold to 1.6 eV above threshold. The experimental data are in good agremeent with a seven-state close-coupling calculation throughout the energy range of the experiment. Results agree with calculations showing that more than 90% of the electrons causing excitation are ejected in the backward direction in the center-of-mass frame. This backscattering is shown in both quantum-mechanical and semiclassical calculations. Evidence is observed for high-lying metastable autoionizing states with a lifetime of approximately 0.9 #mu#s which are made to ionize by electron impact.
Energy Technology Data Exchange (ETDEWEB)
A thermoluminescence (TL) sheet and its spatial readout system for in vivo measurement of spatial dose distribution around sources has been newly developed for intracavitary high dose-rate radiation therapy. The TL sheet (40 cm x 50 cm x 200 {mu}m), which is composed of teflon mixed with BaSO{sub 4} (Eu doped) powder, has a linear response with a very wide dynamic range from at least 0.002 cGy to 5000 cGy for {sup 60}Co sources. Phantom test of the TL sheet readout system demonstrated that absorbed dose with TL sheet and that with ionization chamber as standard dosimeter agreed well. For clinical application, TL sheet was attached on an applicator of intracavitary radiation therapy for rectal cancer. After irradiation with high dose-rate {sup 60}Co sources, the in vivo dose distribution on the surface of the rectum was determined. The TL sheet was suggested to provide a convenient means of measuring the dose distribution around {sup 60}Co sources in intracavitary ...
1991-06-01
Measurement of "2"3"3U(n,f) cross-section at n_TOF facility. Statistical analysis
International Nuclear Information System (INIS)
The "2"3"3U(n, f) cross-section has been measured at n_TOF in a wide energy range with a dedicated fission ionization chamber. We report here the results from 0.30 meV to 1 MeV neutron energy. The "2"3"3U(n, f) cross-section has been determined relative to a reference sample of "2"3"5U(n, f) measured simultaneously with the same detector. The very high instantaneous neutron flux and the intrinsically low background of the n TOF installation result in an accuracy around 3% in the whole energy range, while the energy resolution of the neutron beam allows for an accurate description of the fission cross-section by means of R-matrix analysis over a wide energy range. The present data provide the basis for a more precise evaluation of the "2"3"3U fission cross-section, and for improving the reliability of databases needed for the design of new energy systems based on the Th/U cycle. (Author)
2009-02-01
We construct a sample of low-redshift Ly-alpha emission-line selected sources from GALEX grism spectroscopy of nine deep fields to study the role of Ly-alpha emission in galaxy populations with cosmic time. Our final sample consists of 122 (142) sources selected in the redshift interval z=0.195-0.44 (z=0.65-1.25) from the FUV (NUV) channel. We classify the Ly-alpha sources as AGNs if high-ionization emission lines are present in their UV spectra and as galaxies otherwise. These classifications are broadly supported by comparisons with X-ray and optical spectroscopic observations. We classify additional sources as AGNs using line widths for our Ly-alpha emitter (LAE) analysis. Defining the GALEX LAE sample in the same way as high-redshift LAE samples, we show that LAEs constitute only about 5% of NUV-continuum selected galaxies at z~0.3. We also show that they are less common at z~0.3 than they are at z~3. We find that the z~0.3 optically-confirmed Ly-alpha galaxies ...
2009-01-01
Guideline for sampling and analysis of 'tars' and particles in biomass producer gases
Energy Technology Data Exchange (ETDEWEB)
The further development of a Guideline (formerly Protocol) for sampling and analysis of 'tars' from biomass producer gases is reported. This Guideline is being developed as a project within the European Fifth Framework Programme with additional partners from Switzerland and North-America. In this paper an outline and the principle of the Guideline are given. The Guideline is based on isokinetic sampling of particles and 'tar' from the main producer gas duct, particle filtration at high temperature, gas cooling in a liquid quench, 'tar' absorption in a solvent at low temperatures, an optional backup adsorber, and flow measurement and control. The Guideline gives a definition for 'Gravimetric tar' which is the 'tar' number to be determined by the Guideline. Also, the Guideline gives procedures for compound analysis by gas chromatography - mass spectrometry (GC-MS) or gas chromatography - Flame ...
2000-07-01
Grain boundary transport in x-ray irradiated polycrystalline diamond
International Nuclear Information System (INIS)
The transport properties of a 'thin' polycrystalline diamond film are analyzed after the sample exposure to 8.06-keV x-ray radiation. Structure and morphology of the as-grown film have been evaluated by Raman, x-ray diffraction, and scanning electron microscopy techniques. The transport properties have been investigated by measuring dark current-voltage characteristics in the temperature range of 60 to 360 K. Ohmic transport has been evidenced on the as-grown film up to 1.16x10"5 V/cm. After irradiation, nonlinear contributions to the dark current have been evidenced and related to field-assisted thermal ionization of traps. Below 200 K, hopping mechanisms have been observed. Correlations have been found among x-ray irradiation, density of traps involved in the transport processes, and the nonhomogeneous nature of the sample. A simple model of the grain boundary structure is proposed to explain the observations.
2003-05-15
Electron momentum spectroscopy of H_2 and D_2: Ionization to ground and excited final states
International Nuclear Information System (INIS)
The symmetric noncoplanar (e,2e) cross sections (momentum profiles) of H_2 and D_2 for the transitions to the 2p#sigma#_u and 2s#sigma#_g excited ion states have been measured, relative to the ground-state ion transition, using a high-sensitivity multichannel momentum-dispersive electron momentum spectrometer (EMS) at an impact energy of 1200 eV. Newly calculated plane-wave impulse approximation (PWIA) cross sections, based on a full-configuration-interaction H_2 wave function, are compared to the experimental results. These calculations are in better agreement with the experimental results for the transition to the 2s#sigma#_g ion state than the earlier theoretical work of Liu and Smith, Jr. [Phys. Rev. A 31, 3003 (1985)] which has been found to be in error. Nevertheless, significant discrepancies between the relative experimental and theoretical cross sections are observed for the transitions to excited ion states, suggesting a failure of the PWIA description of these processes. The ...
Electric field measurement on time domain generated by corona on insulators on distribution systems
Energy Technology Data Exchange (ETDEWEB)
Radio interference and TV interference are being a problem in urban and rural areas. This interference is generated by high voltage transmission lines as well as distribution lines. The radio noise can be produced by polluted or damaged insulators, and by metal parts of the distribution lines. The corona effect on the surface of the dielectric material produces high frequency electromagnetic fields during the ionization and during the recombination period. Fields of different intensity are produced by positive voltage and negative voltage. The insulator flashover (leaking current) also produces electromagnetic fields. A new technique to measure these fields was developed. This technique measures the radiated fields on time domain and on frequency domain. This permits us to characterize the radiated field and thus identify the type of the source. Several measurements were done varying the type of the RF generator, i.e., new insulator and broken insulator. A ...
1996-12-31
International Nuclear Information System (INIS)
Volatile compounds produced in flexible food packaging materials (LDPE, EVAc, PET/PE/EVOH/PE) during electron beam irradiation were isolated by purge and trap technique and identified by combined gas chromatography-mass spectrometry (GC/MS), after thermal desorption and concentration. For comparison purposes non-irradiated films were also studied. Film samples were irradiated at low (5 kGy, corresponding to cold pasteurization), intermediate (20 kGy, corresponding to cold sterilization) and high (100 kGy) doses. It was observed that a number of volatile compounds are produced after irradiation in all cases. Furthermore the amounts of all volatile compounds increase with increasing irradiation dose. Both primary (methyl-derivatives etc.) as well as secondary i.e. oxidation products (ketones, aldehydes, alcohols, carboxylic acids etc.) are produced upon irradiation. These products may affect organoleptic properties and thus shelf-life of prepackaged irradiated foods. No significant ...
1999-05-01
EVOLUTION OF MASSIVE STARS WITH PULSATION-DRIVEN SUPERWINDS DURING THE RED SUPERGIANT PHASE
International Nuclear Information System (INIS)
Pulsations driven by partial ionization of hydrogen in the envelope are often considered important for driving winds from red supergiants (RSGs). In particular, it has been suggested by some authors that the pulsation growth rate in an RSG can be high enough to trigger an unusually strong wind (or a superwind), when the luminosity-to-mass ratio becomes sufficiently large. Using both hydrostatic and hydrodynamic stellar evolution models with initial masses ranging from 15 to 40 M_s_u_n, we investigate (1) how the pulsation growth rate depends on the global parameters of supergiant stars and (2) what would be the consequences of a pulsation-driven superwind, if it occurred, for the late stages of massive star evolution. We suggest that such a superwind history would be marked by a runaway increase, followed by a sudden decrease, of the wind's mass-loss rate. The impact on the late evolution of massive stars would be substantial, with stars losing a huge fraction of ...
2010-07-01
Energy Technology Data Exchange (ETDEWEB)
Past movement on faults can be dated by measurement of the intensity of ESR signals in quartz. These signals are reset by local lattice deformation and local frictional heating on grain contacts at the time of fault movement. The ESR signals then grow back as a result of bombardment by ionizing radiation from surrounding rocks. The age is obtained from the ratio of the equivalent dose, needed to produce the observed signal, to the dose rate. Fine grains are more completely reset during faulting, and a plot of age vs. grain size shows a plateau for grains below critical size; these grains are presumed to have been completely zeroed by the last fault activity. We carried out ESR dating of fault rocks collected near the Gori nuclear reactor. Most of the ESR signals of fault rocks collected from the basement are saturated. This indicates that the last movement of the faults had occurred before the Quaternary period. However, ESR dates from the Oyong fault zone range ...
2003-02-15
International Nuclear Information System (INIS)
The decay channels of the Ar 2s"-"1 and 2p"-"1 and Kr 3p"-"1 and 3d"-"1 electronic hole states have been investigated by means of photoelectron-photoion coincidence measurements following innershell ionization using synchrotron radiation. With the method of final ion-charge resolving electron spectroscopy it has become possible to disentangle different contributions to the electron spectrum and to determine the decay probabilities P(nl"-"1#->#n+) of the above-mentioned hole states (nl"-"1) to the final ionic charge states n+. A high correlation with threefold or even fourfold charged ions has been found in all cases. Possible decay routes, via cascade or direct double Auger processes, are discussed on the basis of energy-level schemes calculated with the Hartree-Fock method. Special emphasis is laid on the examination of the Kr 3p"-"1 decay process, where the two fine-structure components (j=1/2,3/2) exhibit noticeably different decay probabilities to Kr"3"+ and ...
2002-04-01
Characterisation of polynuclear aromatic sulfur-heterocycles in a coal extract by GC/MS
Energy Technology Data Exchange (ETDEWEB)
Polynuclear aromatic sulphur heterocycles (PASHs) were isolated from a coal extract by two-step separation method using silica gel column chromatography and ligand exchanges thin layer chromatography (PdCl{sub 2}/SiO{sub 2}). The subfraction was examined by capillary column gas chromatography with flame ionization detector and flame photometric detector and gas chromatography - mass spectrometry. Identification was accomplished by comparison of chromatographic retention indices and mass spectra of compounds with those reported in the literature. It was found that the principal structures of the sulphur-containing fraction of Guiding coal extract have 3-4 aromatic rings. Dibenzothiophene, C{sub 1} - C{sub 3} alkylated dibenzothiophenes, benzonaphthothiophene and its alkylated derivatives were the main compounds. Only a few other polynuclear sulfur heterocycles were detected. No benzothiophene and its derivatives were presented. 8 refs., 2 figs., 3 tabs.
1994-06-01
International Nuclear Information System (INIS)
This paper reports regulation of hypoxia inducible factor-1 ? (HIF-1 ?)in hepatoma cells by irradiation. Cobalt chloride (CoCl2), a chemical mimic agent for hypoxia research, was utilized to induce the stable expression of HIF-1 ? in HepG2 cells. The HepG2 cells were irradiated to different doses to observe the changes of HIF-1 ?. The level of intracellular reactive oxygen species (ROS) was assayed by fluorescent microscope and flow cytometry (FCM). The results showed that there were obvious changes in expression of HIF-1 ? after HepG2 cells exposed to radiation, and the changes were positively related with the irradiation dose from 1 Gy to 5 Gy. Moreover, contents of incellular ROS were negatively correlated with above levels of HIF-1 ? from 1 Gy to 3 Gy. The results indicate that irradiation may enhance hypoxic cells HIF-1 ?, and the reduction of intracellular ROS can contribute to the regulation of ionizing radiation on HIF-1 ?. (authors)
2007-10-01
Automatic system for measuring dose-area product (DAP) in ROI fluoroscopy
Energy Technology Data Exchange (ETDEWEB)
A computerized system for monitoring dose-area product (DAP) has been developed for region of interest (ROI) fluoroscopy in which patient exposure is reduced using an x-ray attenuating filter with an aperture. The system includes an IBM compatible computer which is connected through an IEEE-488 interface to an electrometer which measures the charge from a DAP ionization chamber. A digital input/output board connects the computer to the filter placement device to determine whether the filter is in or out of the beam, and to the x-ray generator to determine when the exposure is due to spot filming. The computer logs the DAP from conventional fluoroscopy, ROI fluoroscopy and spot filming separately, applying the appropriate calibration factor for each. Measured DAPs, fluoroscopic DAP rates and exposure times are displayed in real-time. The system has been installed in a GI fluoroscopic room so that the dose-reduction potential of ROI imaging can be evaluated. (author)
1997-04-01
Antibiotic interaction with phospholipid monolayers
Energy Technology Data Exchange (ETDEWEB)
We studied the interactions of tetracycline (TC) antibiotic molecules with phospholipid monolayers with the two-fold aim of elucidating the mechanism of action and providing a first step for the realization of bio-mimetic sensors for such drugs by means of the Langmuir-Blodgett technique. We examined spreading monolayers of three phospholipids in the presence of tetracycline in the subphase by means of surface pressure-area and surface potential-area isotherms as a function of bulk pH. We selected phospholipids with hydrophobic chains of the same length but polar head groups differing either in dimensions and protonation equilibria, i.e. dipalmitoylphosphatidylcholine (DPPC), dipalmitoylphosphatidylethanolamine (DPPE) and dipalmitoylphosphatidic acid (DPPA). The interaction of tetracycline with the three phospholipids was found to be highly dependent on the electric charge of the antibiotic and on the ionization state of the lipid. Significant interactions are ...
2002-12-01
Energy Technology Data Exchange (ETDEWEB)
The aim of this work was to study acute alterations of the enterohepatic recirculation (EHR) of bile acids 3 days after an 8-Gy radiation exposure in vivo in the rat by a washout technique. Using this technique in association with HPLC analysis, the EHR of the major individual bile acids was determined in control and irradiated animals. Ex vivo ileal taurocholate absorption was also studied in Ussing chambers. Major hepatic enzyme activities involved in bile acid synthesis were also measured. Measurements of bile acid intestinal content and intestinal absorption efficiency calculation from washout showed reduced intestinal absorption with significant differences from one bile acid to another: absorption of taurocholate and tauromuricholate was decreased, whereas absorption of the more hydrophobic taurochenodeoxycholate was increased, suggesting that intestinal passive diffusion was enhanced, whereas ileal active transport might be reduced. Basal hepatic secretion was increased only for ...
2004-02-01
A gas-jet ECR ion source at TRIGA-SPEC
International Nuclear Information System (INIS)
The TRIGA-SPEC experiment has been installed recently at the research reactor TRIGA Mainz. Ground state properties like masses, charge radii, spins, and moments of short-lived nuclides can be determined with very-high precision using the Penning trap mass spectrometer TRIGA-TRAP, and the collinear laser spectroscopy setup TRIGA-LASER. Short-lived neutron-rich radionuclides in the mass range 80 < A < 140 are produced by thermal neutron induced fission of e.g. U-235, Pu-239 or Cf-249, respectively. For the extraction and ionization of the fission products a gas-jet system is coupled to a 2.45-GHz ECR ion source for the production of singly charged ions. The gas-jet has been tested on-line and fission products have been extracted. First off-line tests of the ion source have been performed successfully with argon gas. The results of the commissioning test of the ion source and the on-line coupling of the experiments are presented.
2010-03-08
A Remarkable Low-Mass X-ray Binary within 0.1 pc of the Galactic Center
Recent X-ray and radio observations have identified a transient low-mass X-ray binary (LMXB) located only 0.1 pc in projection from the Galactic center, CXOGC J174540.0-290031. In this paper, we report the detailed analysis of X-ray and infrared observations of the transient and its surroundings. Chandra bservations detect the source at a flux of F_X = 2e-12 erg cm^-2 s^-1 (2-8 keV). After accounting for absorption both in the interstellar medium and in material local to the source, the implied luminosity of the source is only L_X = 4e34 erg/s (2-8 keV; D=8 kpc). However, the diffuse X-ray emission near the source also brightened by a factor of 2. The enhanced diffuse X-ray emission lies on top of a known ridge of dust and ionized gas that is visible infrared images. We interpret the X-ray emission as scattered flux from the outburst, and determine that the peak luminosity of CXOGC J174540.0-290031 was >2e36 erg/s. We suggest that the relatively small observed ...
2005-01-01
/sup 252/Cf-source-driven neutron noise analysis measurements for coupled uranium metal cylinders
Energy Technology Data Exchange (ETDEWEB)
The /sup 252/Cf-source-driven neutron noise analysis method for obtaining the subcriticality of an assembly of fissile material from cross-power spectral densities (CPSDs) was developed to avoid some difficulties inherent in other measurement methods. This method requires measurement of frequency-dependent CPSD between a pair of detectors in or near the fissile assembly and CPSDs between these detectors and a source of correlated neutron noise from an ionization chamber containing /sup 252/Cf, also in or near the fissile assembly. Also, the auto-power spectral density of the source is required. The ratio of spectral densities is then formed and is related to the subcriticality. To date various measurements have been performed which demonstrate the usefulness of the method including measurements with single uranium metal cylinders. The experiments described here, which used coupled uranium (93.15 wt % /sup 235/U) metal cylinders separated by air, are the first ...
1985-01-01
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.
