WorldWideScience

Sample records for abbott prism run

  1. Mercury contamination from mine and natural sources in Harley Gulch, downstream from the Abbott and Turkey Run Mercury Mines, Lake County, California

    Hothem, R. L.; Rytuba, J. J.; Goldstein, D.; Brussee, B.

    2011-12-01

    The Abbott and Turkey Run Mercury (Hg) mine area in central California has released Hg tailings into the Harley Gulch watershed since 1862. Harley Gulch flows into Cache Creek which is a significant source of Hg into San Francisco Bay Delta. Thermal mine water effluent emanating from the Turkey Run adit flows into the upper part of the watershed. Despite remediation efforts, Hg tailings and enriched sediment remain in the Harley Gulch wetlands and in the creek downstream from the mine area. Water, sediment, and biota have been sampled from below the mine area to 15 km downstream to the confluence with Cache Creek in order to assess the impact of Hg on water quality and biota. Two previously unrecognized natural sources of Hg in the watershed are connate groundwater with elevated levels of Hg, and biogenic sediment composed of phytoplankton that accumulates in the upper part of the watershed during the dry season. The connate groundwater source contains isotopically-heavy Mg-Ca-Cl-CO3-SO4 water that has elevated concentrations of Ba, W, Ti, and Hg. This water first enters Harley Gulch in the central part of the wetland immediately downstream from the mine area and continues to contribute water downstream for a distance of 1.5 km. It is both chemically and isotopically distinct from the thermal mine water effluent from the Turkey Run adit. The biogenic source consists of blooms of phytoplankton that accumulate to a thickness of up to 0.2 m. Phytoplankton have a large bioaccumulation factor of Hg and monomethyl mercury (MMeHg) that results in a high concentrations of Hg and MMeHg (Hg: 5-25 μg/g, MMeHg 5.2 ng/g) in the biogenic sediment. The tan biogenic sediment at the surface consists of living diatoms and below it is a layer of black reduced biogenic sediment consisting of diatom fragments with micron- to submicron-sized FeS, HgS, and barite grains. Sulfate-reducing bacteria reduce sulfate to sulfide in the pore waters of the biogenic sediment that reacts with

  2. Abbott Infant Formula Recall

    U.S. Department of Health & Human Services — This list includes products subject to recall since September 2010 related to infant formula distributed by Abbott. This list will be updated with publicly...

  3. Technology evaluation: ABT-510, Abbott.

    Westphal, J.R.

    2004-01-01

    ABT-510 is a small peptide thrombospondin-1 mimetic angiogenesis inhibitor under development by Abbott Laboratories for the potential treatment of solid tumors. ABT-510 is undergoing phase II clinical trials.

  4. FDA Abbott Infant Formula Recall

    U.S. Department of Health & Human Services — On September 22, 2010, Abbott issued a voluntary recall of certain Similac powdered infant formula after identifying a common warehouse beetle (both larvae and...

  5. Technology evaluation: adalimumab, Abbott laboratories.

    Lorenz, Hanns M

    2002-04-01

    Adalimumab (D2E7), a human monoclonal antibody that binds to and neutralizes TNFa, is being developed by Abbott (formerly Knoll), under license from Cambridge Antibody Technology (CAT), for the potential treatment of inflammatory disorders such as rheumatoid arthritis (RA) and Crohn's disease. It is also being investigated for the potential treatment of coronary heart disease. Phase II studies for Crohn's disease and phase III for RA were ongoing throughout 2001. Limited data are only available for RA. In January 2002, it was reported that phase III trials of adalimumab for RA had been completed, but details have not been published in the primary literature so far. At this time CAT and Abbott expected to file for US approval in the second quarter of 2002 with a launch date anticipated for 2003. Phase III data are expected to be presented at the European League Against Rheumatism meeting in June 2002. In November 2000, Lehman Brothers predicted a US launch in June 2002 with peak US sales of $600 million in 2007 and a launch in non-US markets in 2003 with peak sales in these markets of $300 million in 2008. In December 2000, Merrill Lynch predicted regulatory clearance in the second half of 2003. The probability of adalimumab reaching the market is estimated to be 70%. In December 2000, Merrill Lynch predicted a 2003 launch, with estimated sales of pounds sterling 3.65 million in that year rising to pounds sterling 30.14 million in 2010. In March 2001, ABN AMRO predicted sales of $73 million in 2003 rising to $392 million in 2007. PMID:12044041

  6. 75 FR 80061 - Abbott Laboratories, Inc.; Withdrawal of Approval of a New Drug Application for MERIDIA

    2010-12-21

    ... HUMAN SERVICES Food and Drug Administration Abbott Laboratories, Inc.; Withdrawal of Approval of a New... (sibutramine hydrochloride (HCl)) oral capsules held by Abbott Laboratories, Inc. (Abbott), 100 Abbott Park Rd., Abbott Park, IL 60064. Abbott has voluntarily requested that approval of this application be...

  7. 77 FR 13232 - Abbott Laboratories; Filing of Food Additive Petition

    2012-03-06

    ... HUMAN SERVICES Food and Drug Administration 21 CFR Part 172 Abbott Laboratories; Filing of Food Additive... Administration (FDA) is announcing that Abbott Laboratories has filed a petition proposing that the food additive...))), notice is given that a food additive petition (FAP 2A4788) has been filed by Abbott Laboratories,...

  8. 77 FR 4368 - Abbott Laboratories, Diagnostics Division, Including On-Site Leased Workers From Manpower...

    2012-01-27

    ... Employment and Training Administration Abbott Laboratories, Diagnostics Division, Including On-Site Leased... for Worker Adjustment Assistance on February 24, 2011, applicable to workers of Abbott Laboratories... location of Abbott Laboratories, Diagnostics Division. The Department has determined that these...

  9. Australopithecine enamel prism patterns.

    Vrba, E S; Grine, F E

    1978-11-24

    Following a recent suggestion that tooth enamel prism shape differs within Hominoidea, the teeth of a number of extinct and extant hominoid species were analyzed by scanning electron microscopy. The enamel prism patterns of some gracile and robust australopithecine specimens from Sterkfontein, Swartkrans, and Kromdraai are recorded. The characteristic arrangements of enamel prisms in all modern and extinct hominoid species were found to be essentially similar. The implications of enamel prisms for phylogenetic deduction in Hominoidea are discussed. PMID:102032

  10. Berenice Abbott (1898-1991, photographies

    Juliette Mélia

    2012-05-01

    Full Text Available C’est la première fois que Berenice Abbott est exposée à Paris. Les cent vingt images et trente documents présentés au Jeu de Paume sont regroupés en quatre grandes séries, qui correspondent aux quatre grandes phases de sa carrière photographique. La première partie retrace son œuvre de portraitiste, qui commence à Paris au début des années 1920, où elle photographie des anonymes, mais aussi beaucoup d’artistes et d’écrivains tels que Marcel Duchamp, Jean Cocteau, James Joyce, ou encore Djuna...

  11. Collaborative evaluation of the Abbott yeast identification system.

    Cooper, B. H.; Prowant, S; B. Alexander; Brunson, D H

    1984-01-01

    The Abbott yeast identification system (Abbott Laboratories, Diagnostics Division, Irving, Tex.) is a 24-h, instrumental method for identifying medically important yeasts, based on matrix analysis of 19 biochemical reactions and the germ tube test. The system was evaluated in two clinical laboratories by using 179 coded isolates, which included a high percentage of the less frequently encountered species. Based upon results with these coded isolates and from previously obtained laboratory dat...

  12. Multisite Analytical Evaluation of the Abbott ARCHITECT Cyclosporine Assay.

    Wallemacq, Pierre; Maine, Gregory,; Berg, Keith; Rosiere, Thomas; Marquet, Pierre; Aimo, Giuseppe; Mengozzi, Giulio; Young, Juliana; Wonigert, Kurt; Krestchmer, Robert; Wermuth, Bendicht; Schmid, Rainer,

    2010-01-01

    International audience The objective of this study was to evaluate the analytical performance of the Abbott ARCHITECT Cyclosporine (CsA) immunoassay in 7 clinical laboratories in comparison to liquid chromatography/tandem mass spectrometry (LC/MS/MS), Abbott TDx, Cobas Integra 800, and the Dade Dimension Xpand immunoassay. The ARCHITECT assay uses a whole blood specimen, a pretreatment step with organic reagents to precipitate proteins and extract the drug, followed by a 2-step automated i...

  13. Viterbi training in PRISM

    Sato, Taisuke; Kubota, Keiichi

    2013-01-01

    VT (Viterbi training), or hard EM, is an efficient way of parameter learning for probabilistic models with hidden variables. Given an observation $y$, it searches for a state of hidden variables $x$ that maximizes $p(x,y \\mid \\theta)$ by coordinate ascent on parameters $\\theta$ and $x$. In this paper we introduce VT to PRISM, a logic-based probabilistic modeling system for generative models. VT improves PRISM in three ways. First VT in PRISM converges faster than EM in PRISM due to the VT's t...

  14. The PRISM Benchmark Suite

    Kwiatkowsa, Marta; Norman, Gethin; Parker, David

    2012-01-01

    We present the PRISM benchmark suite: a collection of probabilistic models and property specifications, designed to facilitate testing, benchmarking and comparisons of probabilistic verification tools and implementations.

  15. Quantitation of human chorionic gonadotropin with the Abbott IMx immunochemistry analyzer.

    van Oers, R J; Leerkes, B; Bertschi, I

    1990-01-01

    The analytical performance of the Abbott IMx automated system was studied and initial results from the human chorionic gonadotropin assay are presented: Within run and between day precision was good, the majority of all CVs lying between 3 and 5%; Patient results showed excellent comparability with our routine method; No significant specimen-related carry-over was detected; The automated IMx dilution protocol was found to be superior to the manual procedure; The usefulness of the instrument in routine use and as a "Stat" analyzer was very good. PMID:2179460

  16. Analýza marketingové komunikace divize Abbott Diabetes Care, spol. Abbott Laboratories, s.r.o.

    Iblová, Mirka

    2009-01-01

    This dissertation discusses the analysis of marketing communication within Abbott Laboratories Ltd. division of Abbott Diabetes Care, which carry business within the market of pharmaceutical industry. Prior to the analysis, the focus is on the theoretical part of the traditional components of the communication mix. In the practical part, the theoretical knowledge is then applied to the chosen example of the company. On the basis of performed analysis, recommendations are proposed in order to ...

  17. Penta prism laser polarizer.

    Lotem, H; Rabinovitch, K

    1993-04-20

    A novel type of laser prism polarizer is proposed. The polarizer is characterized by a high transmission efficiency, a high optical damage threshold, and a high extinction ratio. The polarizer is shaped like a regular penta prism and, thus, it is a constant deviation angle device. Polarization effects occur upon the two internal cascade reflections in the prism. Anisotropic and Isotropic types of the polarizer are discussed. The isotropic polarizer is a prism made of a high refractive-index glass coated by multilayer polarization-type dielectric coatings. Efficient s-state polarization is obtained because of p-state leakage upon the two internal cascade reflections. The anisotropic polarizer is made of a birefringent crystal in which angular polarization splitting is obtained by the bireflectance (double-reflection) effect. Fanning of a laser beam into up to eight polarized beams is possible in a prism made of a biaxial crystal. PMID:20820335

  18. PRISM Spectrograph Optical Design

    Chipman, Russell A.

    1995-01-01

    The objective of this contract is to explore optical design concepts for the PRISM spectrograph and produce a preliminary optical design. An exciting optical configuration has been developed which will allow both wavelength bands to be imaged onto the same detector array. At present the optical design is only partially complete because PRISM will require a fairly elaborate optical system to meet its specification for throughput (area*solid angle). The most complex part of the design, the spectrograph camera, is complete, providing proof of principle that a feasible design is attainable. This camera requires 3 aspheric mirrors to fit inside the 20x60 cm cross-section package. A complete design with reduced throughput (1/9th) has been prepared. The design documents the optical configuration concept. A suitable dispersing prism material, CdTe, has been identified for the prism spectrograph, after a comparison of many materials.

  19. 76 FR 4283 - Foreign-Trade Zone 153-San Diego, CA; Application for Manufacturing Authority; Abbott...

    2011-01-25

    ...; Abbott Cardiovascular Systems, Inc. (Cardiovascular Device Manufacturing); Riverside County, CA An.... (Abbott), located in Riverside County, California. The application was submitted pursuant to the... sourced from abroad (representing 5% of the value of the finished product) include: resins, plastic...

  20. Acoustic dispersive prism

    Hussein Esfahlani; Sami Karkar; Herve Lissek; Mosig, Juan R.

    2016-01-01

    The optical dispersive prism is a well-studied element, which allows separating white light into its constituent spectral colors, and stands in nature as water droplets. In analogy to this definition, the acoustic dispersive prism should be an acoustic device with capability of splitting a broadband acoustic wave into its constituent Fourier components. However, due to the acoustical nature of materials as well as the design and fabrication difficulties, there is neither any natural acoustic ...

  1. 77 FR 75610 - Foreign-Trade Zone 22-Chicago, IL, Notification of Proposed Production Activity, Abbott...

    2012-12-21

    ..., Abbott Laboratories, Inc., AbbVie, Inc. (Pharmaceutical Production), North Chicago, IL, Area Abbott Laboratories, Inc. (Abbott) and AbbVie, Inc. (AbbVie) submitted a notification for expanded production... (Board Order 611, 12/ 14/1991, 57 FR 61045, 12/14/1992) and authority was later expanded in 1999 and...

  2. 78 FR 54487 - Abbott Laboratories; Diagnostic-Hematology; Including On-Site Leased Workers From Manpower...

    2013-09-04

    ... Employment and Training Administration Abbott Laboratories; Diagnostic--Hematology; Including On-Site Leased... on-site at the Santa Clara, California location of Abbott Laboratories, Diagnostic--Hematology... International, reporting to Abbott Laboratories, Diagnostic--Hematology division, including on-site...

  3. The Instructional Guide for Abbott Skills Enhancement Classes. Revised Edition.

    Ballinger, Ronda; Gee, Mary Kay

    This guide, which integrates adult basic education (ABE) curriculum, job skills for Abbott Laboratories, and work-related foundation skills, is designed for an instructional program in the skill areas of reading, writing, oral communications, mathematics, and problem solving. In addition to creating a uniform process and product to promote…

  4. Development of the Abbott MATRIX Aero assay for the measurement of specific IgE.

    Lindberg, R E; Anawis, M A; Bailey, M; Mangat, D; Frank, P M; Hrusovsky, I G; Hooyman, L; Putterman, C; Defreese, J D

    1991-01-01

    An enzyme immunoassay has been developed for the quantitation of specific immunoglobulin E (IgE) in human serum to a panel of allergens. The assay system, called the Abbott MATRIX Aero, includes an instrument, reagents and test cell disposables. Each test cell contains fourteen airborne allergens individually localized on a nitrocellulose solid phase. Individual calibration curves for each allergen are established by the manufacturer and included in barcode form with each test kit. Stable factory calibration eliminates the need to establish a calibration curve with each assay run. The instrument automatically incubates, washes, and reads the test cell and prints each result, which ensures assay reproducibility and provides ease-of-use. Analysis of test results shows good agreement with another in vitro assay for specific IgE. The Abbott MATRIX Aero is a sensitive, reproducible and easy-to-use system for the measurement of specific IgE to a panel of fourteen allergens simultaneously using a single, small volume of serum. PMID:1806584

  5. Geometric formula for prism deflection

    Apoorva G Wagh; Veer Chand Rakhecha

    2004-08-01

    While studying neutron deflections produced by a magnetic prism, we have stumbled upon a simple `geometric' formula. For a prism of refractive index close to unity, the deflection simply equals the product of the refractive power − 1 and the base-to-height ratio of the prism, regardless of the apex angle. The base and height of the prism are measured respectively along and perpendicular to the direction of beam propagation within the prism. The geometric formula greatly simplifies the optimisation of prism parameters to suit any specific experiment.

  6. PRISM project optical instrument

    Taylor, Charles R.

    1994-01-01

    The scientific goal of the Passively-cooled Reconnaissance of the InterStellar Medium (PRISM) project is to map the emission of molecular hydrogen at 17.035 micrometers and 28.221 micrometers. Since the atmosphere is opaque at these infrared wavelengths, an orbiting telescope is being studied. The availability of infrared focal plane arrays enables infrared imaging spectroscopy at the molecular hydrogen wavelengths. The array proposed for PRISM is 128 pixels square, with a pixel size of 75 micrometers. In order to map the sky in a period of six months, and to resolve the nearer molecular clouds, each pixel must cover 0.5 arcminutes. This sets the focal length at 51.6 cm. In order for the pixel size to be half the diameter of the central diffraction peak at 28 micrometers would require a telescope aperture of 24 cm; an aperture of 60 cm has been selected for the PRISM study for greater light gathering power.

  7. Prism vergence measurements following adaptation to a base out prism

    Tuff, L.C.; Firth, A Y; Griffiths, H.J.

    2000-01-01

    This study examines the effect of adaptation on the prism vergence range following an induced deviation. Five young adult subjects, with normal binocular functions, underwent fusional verfence testing to base in prisms before and after wearing a 10(Δ) base out Fresnel prism. The Fresnel prism was worn for a period of 2, 5, or 10 min on each of three separate occasions. The base in fusional vergence showed no statistical difference before or after adaptation, for any of the time periods. Also ...

  8. 77 FR 16039 - Abbott Laboratories et al.; Withdrawal of Approval of 35 New Drug Applications and 64 Abbreviated...

    2012-03-19

    ... HUMAN SERVICES Food and Drug Administration Abbott Laboratories et al.; Withdrawal of Approval of 35 New... Application No. Drug Applicant NDA 005545 Dicumarol Tablets... Abbott Laboratories, PA77/Bldg. AP30-1E, 200...)) Injection Preservative Free. NDA 010021 Placidyl Abbott Laboratories, (ethchlorvynol) 200 Abbott...

  9. Ultra-dispersive adaptive prism

    Sautenkov, Vladimir A.; Li, Hebin; Rostovtsev, Yuri V.; Scully, Marlan O.

    2007-01-01

    We have experimentally demonstrated an ultra-dispersive optical prism made from coherently driven Rb atomic vapor. The prism possesses spectral angular dispersion that is six orders of magnitude higher than that of a prism made of optical glass; it is the highest spectral angular dispersion that has ever been shown (such angular dispersion allows one to spatially resolve light beams with different frequencies separated by a few kHz). The prism operates near the resonant frequency of atomic va...

  10. Acoustic dispersive prism

    Esfahlani, Hussein; Karkar, Sami; Lissek, Herve; Mosig, Juan R.

    2016-01-01

    The optical dispersive prism is a well-studied element, which allows separating white light into its constituent spectral colors, and stands in nature as water droplets. In analogy to this definition, the acoustic dispersive prism should be an acoustic device with capability of splitting a broadband acoustic wave into its constituent Fourier components. However, due to the acoustical nature of materials as well as the design and fabrication difficulties, there is neither any natural acoustic counterpart of the optical prism, nor any artificial design reported so far exhibiting an equivalent acoustic behaviour. Here, based on exotic properties of the acoustic transmission-line metamaterials and exploiting unique physical behaviour of acoustic leaky-wave radiation, we report the first acoustic dispersive prism, effective within the audible frequency range 800 Hz-1300 Hz. The dispersive nature, and consequently the frequency-dependent refractive index of the metamaterial are exploited to split the sound waves towards different and frequency-dependent directions. Meanwhile, the leaky-wave nature of the structure facilitates the sound wave radiation into the ambient medium.

  11. Dove prism heterodyne refractometer

    Hsu, Cheng-Chih; Lee, Chia-Yun; Chu, Kuan-Ho; Wu, Tsai-Chen

    2015-10-01

    In this study, we proposed an alternative method, integrating a Dove prism and precision circular heterodyne interferometry, for measuring the refractive index and concentration of sodium chloride and hydrogen peroxide solutions with low phase error. Due to the optical properties of the Dove prism, the test light undergoes total internal reflection (TIR) at the interface between the test sample and the prism. The light beam travels in and out of the Dove prism while maintaining the same direction. Therefore, only slight alignment is required, leading to only small errors in the phase and refractive index. In this study, the phase error, refractive index error, and resolution of the concentration are approximated to be 0.003°, 2×10-5, and 1×10-3 M, respectively. The proposed method has the advantages of a simple optical configuration, ease of operation, little alignment required, and high stability, and it allows for high-precision measurement of the refractive index and concentration of the liquid sample.

  12. Prism Adaptation in Schizophrenia

    Bigelow, Nirav O.; Turner, Beth M.; Andreasen, Nancy C.; Paulsen, Jane S.; O'Leary, Daniel S.; Ho, Beng-Choon

    2006-01-01

    The prism adaptation test examines procedural learning (PL) in which performance facilitation occurs with practice on tasks without the need for conscious awareness. Dynamic interactions between frontostriatal cortices, basal ganglia, and the cerebellum have been shown to play key roles in PL. Disruptions within these neural networks have also…

  13. Generalization of Prism Adaptation

    Redding, Gordon M.; Wallace, Benjamin

    2006-01-01

    Prism exposure produces 2 kinds of adaptive response. Recalibration is ordinary strategic remapping of spatially coded movement commands to rapidly reduce performance error. Realignment is the extraordinary process of transforming spatial maps to bring the origins of coordinate systems into correspondence. Realignment occurs when spatial…

  14. Reflection by Porro Prisms

    Greenslade, Thomas B.

    2010-04-01

    Students all know that reflection from a plane mirror produces an image that is reversed right to left and so cannot be read by anyone but Leonardo da Vinci, who kept his notes in mirror writing. A useful counter-example is the Porro prism, which produces an image that is not reversed.

  15. Avoidance of generic competition by Abbott Laboratories' fenofibrate franchise.

    Downing, Nicholas S; Ross, Joseph S; Jackevicius, Cynthia A; Krumholz, Harlan M

    2012-05-14

    The ongoing debate concerning the efficacy of fenofibrate has overshadowed an important aspect of the drug's history: Abbott Laboratories, the maker of branded fenofibrate, has produced several bioequivalent reformulations that dominate the market, although generic fenofibrate has been available for almost a decade. This continued use of branded formulations, which cost twice as much as generic versions of fenofibrate, imposes an annual cost of approximately $700 million on the US health care system. Abbott Laboratories maintained its dominance of the fenofibrate market in part through a complex switching strategy involving the sequential launch of branded reformulations that had not been shown to be superior to the first-generation product and patent litigation that delayed the approval of generic formulations. The small differences in dose of the newer branded formulations prevented their substitution with generics of older-generation products. As soon as direct generic competition seemed likely at the new dose level, where substitution would be allowed, Abbott would launch another reformulation, and the cycle would repeat. Based on the fenofibrate example, our objective is to describe how current policy can allow pharmaceutical companies to maintain market share using reformulations of branded medications, without demonstrating the superiority of next-generation products. PMID:22493409

  16. A displacement-doubling prism

    A novel prism has been devised which can be used in place of the ‘flag’ in an optical shadow-sensing type of displacement sensor, for example. In this way, theoretically the displacement sensitivity of the sensor can be doubled. Such a prism has been manufactured, and its displacement-doubling property has been verified. - Highlights: • A new type of glass prism doubles linear displacement of optical beams. • Optical operation has been verified. • Light beams enter and exit at normal incidence to prism's windows. • Optical path length through prism remains constant, as prism is moved. • Designed to double the displacement sensitivity of knife-edge shadow sensors

  17. 78 FR 23220 - Foreign-Trade Zone 22-Chicago, Illinois, Authorization of Production Activity, Abbott...

    2013-04-18

    ..., Abbott Laboratories, Inc., AbbVie, Inc. (Pharmaceutical Production), North Chicago, Illinois, Area On December 14, 2012, Abbott Laboratories, Inc., and AbbVie, Inc., submitted a notification for expanded... FTZ Board (15 CFR part 400), including notice in the Federal Register inviting public comment (77...

  18. Multibeam collimator uses prism stack

    Minott, P. O.

    1981-01-01

    Optical instrument creates many divergent light beams for surveying and machine element alignment applications. Angles and refractive indices of stack of prisms are selected to divert incoming laser beam by small increments, different for each prism. Angles of emerging beams thus differ by small, precisely-controlled amounts. Instrument is nearly immune to vibration, changes in gravitational force, temperature variations, and mechanical distortion.

  19. Optical design of prism-grating-prism imaging spectrometers

    Zhu, Shanbing; Tang, Minxue; Ji, Yiqun; Gong, Guangbiao; Zhang, Ruirui; Shen, Weimin

    2008-12-01

    Imaging spectrometers can provide imagery and spectrum information of objects and form so-called three-dimensional spectral imagery, two spatial and one spectral dimension. Most of imaging spectrometers use conventional spectroscopic elements or systems, such as reflective diffraction gratings, prisms, filters, spatial modulated interferometers, and so on. Here a special imaging spectrometer which is based on a novel cemented Prism-Grating-Prism (PGP) is reported. Its spectroscopic element PGP consists of two prisms and a holographic transmission volume grating, which is cemented between these prisms. The two prisms mainly function as beam deviation, the grating as a disperser. In addition to the high light efficiency of the volume gratings that is required for high spectral resolution, the cementing difficulty when surface relief gratings are used can be avoided due to its voluminal characteristic. The PGP imaging spectrometer has advantages of direct vision, dispersion uniform, compactness, low cost, and facility to be used. The principle, structure, and optimized design of the PGP imaging spectrometer are given in detail. Its front collimation optics and rear focusing lenses are same so as to reduce its cost further. The spectral coverage, resolution, and track length of the designed system are respectively visible light from 400nm to 800nm, 1.6nm/pixel, and 85mm. From its performance evaluation, it is shown that the PGP imaging spectrometer has the potentiality to be used in microscopic hyperspectral imagers and hyperspectral imaging remote sensors.

  20. 21 CFR 886.1660 - Gonioscopic prism.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gonioscopic prism. 886.1660 Section 886.1660 Food... DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1660 Gonioscopic prism. (a) Identification. A gonioscopic prism is a device that is a prism intended to be placed on the eye to study the anterior...

  1. Prism Window for Optical Alignment

    Tang, Hong

    2008-01-01

    A prism window has been devised for use, with an autocollimator, in aligning optical components that are (1) required to be oriented parallel to each other and/or at a specified angle of incidence with respect to a common optical path and (2) mounted at different positions along the common optical path. The prism window can also be used to align a single optical component at a specified angle of incidence. Prism windows could be generally useful for orienting optical components in manufacture of optical instruments. "Prism window" denotes an application-specific unit comprising two beam-splitter windows that are bonded together at an angle chosen to obtain the specified angle of incidence.

  2. A neutron prism

    A neutron detector with an energy and time resolution makes it possible to realize a new type of a scattering instrument. Such kind of detector can be developed by combining the neutron refractive device (neutron prism) and position-sensitive-detector (PSD) with a time resolution. As the neutron refractive device, two candidates are considered; a compound refractive device and magnetic field gradient. In former case, suitable choice of material and design of the refractive device overcomes a problem of neutron absorption and weak refraction due to material. On the other hand, the magnetic field gradient has an advantage that it has a large refraction and zero neutron absorption comparing with the compound refractive device. A refractive device has been developed with suitable material and design for neutron optics and a quadrupole magnet with permanent magnets in which a constant field gradient is realized. In this paper, the construction and performance of the energy and time resoluble detectors using the neutron refractive devices are described and their application to a neutron scattering experiment is discussed. (author)

  3. Detection of respiratory syncytial virus antigen in nasal washings by Abbott TestPack enzyme immunoassay.

    Wren, C G; Bate, B J; Masters, H B; Lauer, B A

    1990-01-01

    We compared the new Abbott TestPack (TP) respiratory syncytial virus (RSV) enzyme immunoassay (EIA) with cell culture and two commercial RSV EIAs (from Abbott Diagnostics and Kallestad Laboratories) by using split samples of fresh nasal washings from children with suspected RSV disease. Two tubes of HEp-2 cells were inoculated and observed for cytopathic effect for 14 days, and isolates were confirmed by immunofluorescence. The TP EIA was performed by following the manufacturer's instructions...

  4. Running the running

    Cabass, Giovanni; Melchiorri, Alessandro; Pajer, Enrico; Silk, Joseph

    2016-01-01

    We use the recent observations of Cosmic Microwave Background temperature and polarization anisotropies provided by the Planck satellite experiment to place constraints on the running $\\alpha_\\mathrm{s} = \\mathrm{d}n_{\\mathrm{s}} / \\mathrm{d}\\log k$ and the running of the running $\\beta_{\\mathrm{s}} = \\mathrm{d}\\alpha_{\\mathrm{s}} / \\mathrm{d}\\log k$ of the spectral index $n_{\\mathrm{s}}$ of primordial scalar fluctuations. We find $\\alpha_\\mathrm{s}=0.011\\pm0.010$ and $\\beta_\\mathrm{s}=0.027\\pm0.013$ at $68\\%\\,\\mathrm{CL}$, suggesting the presence of a running of the running at the level of two standard deviations. We find no significant correlation between $\\beta_{\\mathrm{s}}$ and foregrounds parameters, with the exception of the point sources amplitude at $143\\,\\mathrm{GHz}$, $A^{PS}_{143}$, which shifts by half sigma when the running of the running is considered. We further study the cosmological implications of this anomaly by including in the analysis the lensing amplitude $A_L$, the curvature parameter ...

  5. Evaluation of the Abbott LCx Assay for Detection of Neisseria gonorrhoeae in Endocervical Swab Specimens from Females

    Kehl, Sue C.; Georgakas, Kristina; Swain, Geoffrey R.; Sedmak, Gerald; Gradus, Stephen; Singh, Ajaib; Foldy, Seth

    1998-01-01

    The Abbott LCx Neisseria gonorrhoeae assay (Abbott Laboratories, Abbott Park, Ill.) uses a ligase chain reaction (LCR) amplification in the LCx probe system for detection of a specific nucleotide sequence in the Opa-encoding gene of N. gonorrhoeae. We evaluated the LCx assay in a comparison with conventional culture employing modified Thayer-Martin media for the detection of N. gonorrhoeae from female endocervical specimens obtained from patients attending a sexually transmitted disease clini...

  6. Rotatable prism for pan and tilt

    Ball, W. B.

    1980-01-01

    Compact, inexpensive, motor-driven prisms change field of view of TV camera. Camera and prism rotate about lens axis to produce pan effect. Rotating prism around axis parallel to lens produces tilt. Size of drive unit and required clearance are little more than size of camera.

  7. Preserving with Prisms: Producing Nets

    Prummer, Kathy E.; Amador, Julie M.; Wallin, Abraham J.

    2016-01-01

    Two mathematics teachers in a small rural school decided to create a task that would engage seventh graders. The goal of the real-world activity was to help students develop geometric and spatial reasoning and to support their understanding of volume of rectangular prisms. The impetus for the task came from the teachers' desire to engage students…

  8. Cethromycin: A-195773, A-195773-0, A-1957730, Abbott-195773, ABT 773.

    2007-01-01

    Cethromycin [ABT 773, A-195773, Abbott-195773, A-1957730, A-195773-0] is a once-daily ketolide antibiotic that originated from Abbott Laboratories' research into next-generation compounds to the macrolide antibacterial, clarithromycin. The aim of the research programme was to maintain the positive attributes of clarithromycin and to add the property of efficacy against macrolide-resistant organisms. Cethromycin acts by binding to the 23S molecule of the 50S ribosomal subunit. Advanced Life Sciences is conducting multinational, pivotal phase III trials of cethromycin for the treatment of mild-to-moderate community-acquired pneumonia, phase II/III trials for treatment of acute bacterial sinusitis, as well as preclinical trials for the treatment of anthrax. Advanced Life Sciences plans to advance discussions with prospective commercialisation partners for cethromycin during 2006. Abbott Laboratories and Taisho Pharmaceutical entered a collaboration to develop and commercialise new macrolide antibacterials in October 1997. Each company brought its existing macrolides into the collaboration and both companies were to jointly develop novel new macrolides. Abbott was to have exclusive marketing, manfacturing and supply rights worldwide (except in Japan) to any compounds resulting from this collaboration. Taisho was to receive royalties on Abbott's sales in consideration of granted rights. In Japan, the two companies were to co-market any resulting macrolide antibacterials. This agreement extended to the development of cethromycin; however, the agreement was suspended in April 2004 and appears to have been terminated. Abbott exclusively licensed cethromycin to Advanced Life Sciences worldwide excluding Japan in December 2004. Advanced Life Sciences initiated commercial manufacturing agreements for cethromycin with DSM and Cardinal Health in May 2006. In March 2006, Advanced Life Sciences completed private placement of $US36 million from which the net proceeds will be used

  9. A Liquid Prism for Refractive Index Studies

    Edmiston, Michael D.

    2001-11-01

    A hollow glass prism filled with liquid becomes a "liquid prism". A simple method for constructing hollow glass prisms is presented. A method is given for a demonstration that uses the liquid prism with a laser or laser pointer so the audience can observe differences in refractive index for various liquids. The demonstration provides a quick and easy determination of the sugar content of soft drinks and juices. The prism makes it easy to determine a numerical value for the refractive index of a liquid.

  10. Evaluation of the Abbott Real Time HCV genotype II assay for Hepatitis C virus genotyping

    Sariguzel, Fatma Mutlu; Berk, Elife; Gokahmetoglu, Selma; Ercal, Baris Derya; Celik, Ilhami

    2015-01-01

    Objective: The determination of HCV genotypes and subtypes is very important for the selection of antiviral therapy and epidemiological studies. The aim of this study was to evaluate the performance of Abbott Real Time HCV Genotype II assay in HCV genotyping of HCV infected patients in Kayseri, Turkey. Methods: One hundred patients with chronic hepatitis C admitted to our hospital were evaluated between June 2012 and December 2012, HCV RNA levels were determined by the COBAS® AmpliPrep/COBAS® TaqMan® 48 HCV test. HCV genotyping was investigated by the Abbott Real Time HCV Genotype II assay. With the exception of genotype 1, subtypes of HCV genotypes could not be determined by Abbott assay. Sequencing analysis was used as the reference method. Results: Genotypes 1, 2, 3 and 4 were observed in 70, 4, 2 and 24 of the 100 patients, respectively, by two methods. The concordance between the two systems to determine HCV major genotypes was 100%. Of 70 patients with genotype 1, 66 showed infection with subtype 1b and 4 with subtype 1a by Abbott Real Time HCV Genotype II assay. Using sequence analysis, 61 showed infection with subtype 1b and 9 with subtype 1a. In determining of HCV genotype 1 subtypes, the difference between the two methods was not statistically significant (P>0.05). HCV genotype 4 and 3 samples were found to be subtype 4d and 3a, respectively, by sequence analysis. There were four patients with genotype 2. Sequence analysis revealed that two of these patients had type 2a and the other two had type 2b. Conclusion: The Abbott Real Time HCV Genotype II assay yielded results consistent with sequence analysis. However, further optimization of the Abbott Real Time HCV Genotype II assay for subtype identification of HCV is required. PMID:26649001

  11. A multicenter evaluation of the Abbott RealTime HCV genotype II assay

    Marco Ciotti

    2009-12-01

    Full Text Available Viral genotype is an important determinant of the therapeutical outcome of the chronic hepatitis C and is useful in clinical practice to determine the duration of treatment1.While the viral type shows a clear association with therapeutic success, there is currently no evidence to that effect for HCV subtype, whose value is thus confined to epidemiological studies.The Abbott RealTime HCV Genotype II assay, through the use of Minor Groove Binder probes (MGB is able to distinguish genotypes 1 to 6 (target 5’-UTR region and subtypes 1a and 1b (NS5B region. In four different Italian centers a comparison between the Abbott RealTime HCV Genotype II assay and the Versant HCV Genotype 2.0 (LIPA has been performed.A total of 143 non selected samples with the request of HCV genotyping have been analysed. 141/143 samples (98.6% have provided reportable results with both tests (2 indeterminates with LIPA. Concordance at the type level was 96.5% (136/141. Considering the 136 concordant samples, the distribution was as follows: type 1 = 61 (44.9%, 2 = 36 (26.5%, 3 = 21 (15.4%, 4 = 17 (12.5% 5 = 1 (0.7%. Both assays assigned subtype in 56/61 (91.8% samples of genotype 1 (3 and 2 samples only provided the type for LIPA and Abbott, respectively and 50/56 (89.3% had concordant subtype. It is worth to note that 4 of the 5 samples with discordant subtype Abbott 1a/LiPA 1b came from the only center that used for LIPA the 5-UTR amplicon, loosing the benefit of the core region which has been introduced in the version 2 of the test to improve the accuracy in distinguishing between 1a and 1b.There was only one discordant sample at type level (Abbott 4, LIPA 1b which after sequencing and phylogenetic analysis was resolved as type 4. Four mixed infections were detected, 3 with the Abbott test (two 1a+4 and one 1b+3 and 1 with the LIPA test (1a+3. In all cases the comparison test showed a single genotype 1 infection. The new Abbott RealTime HCV Genotype II assay showed a

  12. An Evaluation of the Main Performance of the Abbott Axsym System%美国Abbott Axsym免疫分析仪性能初步评价

    王红旗; 金晶; 成军; 孙长贵; 孙关忠

    2003-01-01

    目的对Abbott Axsym免疫分析仪性能进行评价.方法通过检测HBsAg,对Abbott Axsym免疫分析仪的灵敏度、特异性、正确检测率(可检测性)、重复性、线性及与ELISA检测HBsAg的相关性等指标进行测定.结果Abbott Axsym免疫分析仪的灵敏度达到0.16 μg/L,特异性为100%,正确检测率(可检测性)为99.72%,不同参比血清的总CV值在5.4%~9.4%之间波动,在0.1~100μg/L范围内线性良好(r=0.994 9),与ELISA比较,两法的符合率为97%,结论该仪器设计科学合理,检测快速方便,结果准确可靠,是大、中型医院临床实验室比较理想的免疫分析仪之一.

  13. Early Childhood Education: The Sustainability of the Benefits of Preschool Participation in Abbott Districts

    Fernandez, Norma

    2010-01-01

    The landmark New Jersey Supreme Court school funding case, "Abbott v. Burke", established the availability of preschool for all three- and four-year-olds living within the state's thirty-one poorest districts as a means of eradicating the effects of poverty. Longitudinal studies have shown the value of high quality preschool programs for improving…

  14. 75 FR 340 - Approval for Expansion of Subzone 22F, Abbott Molecular, Inc. (Pharmaceutical and Molecular...

    2010-01-05

    ...- 17-09); Whereas, notice inviting public comment has been given in the Federal Register (74 FR 8052... Foreign-Trade Zones Board Approval for Expansion of Subzone 22F, Abbott Molecular, Inc. (Pharmaceutical and Molecular Diagnostic Products), Chicago, IL, Area Pursuant to its authority under the...

  15. Reproducibility Problems with the Abbott Laboratories LCx Assay for Chlamydia trachomatis and Neisseria gonorrhoeae

    Gronowski, Ann M.; Copper, Susan; Baorto, David; Murray, Patrick R.

    2000-01-01

    This study demonstrates that significant reproducibility problems can occur during routine use of the Abbott Laboratories LCx assay for Chlamydia trachomatis and Neisseria gonorrhoeae. These problems can go undetected by the quality control procedures outlined in the manufacturer's package insert. We outline here procedures for detecting and preventing contamination and reproducibility problems.

  16. The Labour Process of Teaching at John Abbott College (Part One).

    Johnson, Walter

    This survey was conducted at John Abbott College to gauge teachers' responses to issues concerning their job satisfaction, interaction with colleagues, perceptions of student abilities, and perceptions concerning union negotiating priorities and areas of conflict within the institutional environment. Of the 75 teachers contacted, 47 returned…

  17. Neutron forward diffraction by single crystal prisms

    Sohrab Abbas; Apoorva G Wagh; Markus Strobl; Wolfgang Treimer

    2008-11-01

    We have derived analytic expressions for the deflection as well as transmitted fraction of monochromatic neutrons forward diffracted by a single crystal prism. In the vicinity of a Bragg reflection, the neutron deflection deviates sharply from that for an amorphous prism, exhibiting three orders of magnitude greater sensitivity to the incidence angle. We have measured the variation of neutron deflection and transmission across a Bragg reflection, for several single crystal prisms. The results agree well with theory.

  18. Preoperative prism adaptation test in normosensoric strabismus

    Schildwächter-von Langenthal, Annette; Kommerell, Guntram; Klein, Ulrike; Simonsz, Huib

    1989-01-01

    textabstractIn 19 patients with normosensoric esotropia, the squint angles measured with the alternate cover test were compared with those after prolonged prismatic correction of the squint angle and with those after prolonged occlusion of one eye. All patients showed an increase of the squint angle after prism adaptation. The angle was generally smaller after diagnostic occlusion of one eye than after prism adaptation. We assume that the increase in the squint angle after prism adaptation is...

  19. Dispersion Compensation using a Prism-pair

    Shaked, Yaakov; Yefet, Shai; Pe'er, Avi

    2014-01-01

    A simple and intuitive formulation is reviewed for the Brewster prism-pair - A most common component in spectroscopy-oriented experiments using ultrashort pulses. This review aims to provide students and beginners in the field of spectroscopy with a unified description of a major experimental component. The total spectral phase experienced by a broadband light field is calculated after passing through a pair of Brewster-cut prisms, demonstrating the flexibility of the prism pair to provide tu...

  20. The PRISM/PRIME Project

    Lepton Flavour violation is predicted by many theories beyond the standard model. In the muon sector such a violation entails not only direct μ→eγ decay but also the conversion process μ→e. To measure this to high precision requires a large number of muons of very similar energy, and this is difficult to achieve from a muon target with conventional beam optics. PRISM is an FFAG system designed to accept large numbers of muons (1012/sec) with a wide range of energies, and render them monochromatic by accelerating the less energetic muons and decelerating the more energetic ones. To preserve Liouville's theorem, this is accompanied by a broadening in the timing of the muons, hence the name 'Phase Rotated Intense Slow Muon source.' The principles of this device have been demonstrated and components prototyped. PRIME is a detector (PRISM Muon Electron Conversion) which has been designed to stop 20 MeV bunches of muons in a thin foil, giving a very clean signal and reaching a background sensitivity of 10-18, four orders of magnitude better than today's limits and probing the interesting region for BSM theories.

  1. Effect of using heat-inactivated serum with the Abbott human T-cell lymphotropic virus type III antibody test.

    Jungkind, D. L.; DiRenzo, S A; Young, S J

    1986-01-01

    The Abbott enzyme immunoassay (Abbott Laboratories, North Chicago, Ill.) for human T-cell lymphotropic virus type III (HTLV-III) antibody was evaluated to determine the effect of using heat-inactivated (56 degrees C for 30 min) serum as the sample. Each of 58 nonreactive serum samples gave a higher A492 value when tested after heat inactivation. Ten of the samples became reactive after heating. Heat-inactivated serum should not be used in the current Abbott HTLV-III antibody test, because thi...

  2. PRISM: FFAG as a phase rotator

    PRISM is a project in Japan to make a high-intensity low-energy muon source with a narrow energy-spread and high purity. In this report, we present an overview of the PRISM project and its physics applications, especially to a search for muon lepton flavor violation. Its future extension towards a neutrino factory is also mentioned. (author)

  3. The Prism Plastic Calorimeter (PPC)

    2002-01-01

    This proposal supports two goals: \\\\ \\\\ First goal:~~Demonstrate that current, widely used plastic technologies allow to design Prism Plastic Calorimeter~(PPC) towers with a new ``liquid crystal'' type plastic called Vectra. It will be shown that this technique meets the requirements for a LHC calorimeter with warm liquids: safety, hermeticity, hadronic compensation, resolution and time response. \\\\ \\\\ Second goal:~~Describe how one can design a warm liquid calorimeter integrated into a LHC detector and to list the advantages of the PPC: low price, minimum of mechanical structures, minimum of dead space, easiness of mechanical assembly, accessibility to the electronics, possibility to recirculate the liquid. The absorber and the electronic being outside of the liquid and easily accessible, one has maximum flexibility to define them. \\\\ \\\\ The R&D program, we define here aims at showing the feasibility of these new ideas by building nine towers of twenty gaps and exposing them to electron and hadron beams.

  4. Clinical laboratory evaluation of the Abbott MS-2 automated antimicrobial susceptibility testing system: report of a collaborative study.

    Thornsberry, C; Anhalt, J P; Washington, J A; McCarthy, L R; Schoenknecht, F D; Sherris, J. C.; Spencer, H J

    1980-01-01

    The MS-2 system (Abbott Diagnostics, Division of Abbott Laboratories, Dallas, Tex.) was evaluated for its efficacy in determining the susceptibilities of both clinical and selected challenge (nonfastidious, facultative, and aerobic) isolates. The MS-2 results were compared with standard Kirby-Bauer disk diffusion and microdilution results by using fresh clinical isolates. For gram-positive isolates other than enterococci, overall agreement between MS-2 and reference results was 93 to 98%. Wit...

  5. Evaluation of the Abbott TESTPACK RSV enzyme immunoassay for detection of respiratory syncytial virus in nasopharyngeal swab specimens.

    Swierkosz, E M; Flanders, R; Melvin, L; Miller, J D; Kline, M W

    1989-01-01

    The Abbott TESTPACK RSV assay (Abbott Laboratories, North Chicago, Ill.), a rapid (20-min) enzyme immunoassay, was compared with culture and direct immunofluorescence (DFA) of nasopharyngeal cells for the detection of respiratory syncytial virus (RSV) in nasopharyngeal swab specimens. Nasopharyngeal swab specimens, collected from 234 infants, were placed in viral transport medium. Portions of specimen in transport medium were used for each test. Of 234 specimens, 70 (30%) were culture positiv...

  6. Revisiting Abbott Thayer: non-scientific reflections about camouflage in art, war and zoology

    Behrens, Roy R.

    2008-01-01

    This paper reviews the achievements of Abbott Handerson Thayer (1849–1921), an American painter and naturalist whose pioneering writings on animal camouflage addressed shared concerns among artists, zoologists and military tacticians. It discusses his beliefs about camouflage (both natural and military) in the context of his training as an artist, with particular emphasis on three of his major ideas: countershading, ruptive (or disruptive) coloration and background picturing.

  7. Automation of the Limulus amoebocyte lysate test by using the Abbott MS-2 microbiology system.

    Jorgensen, J H; Alexander, G A

    1981-01-01

    A rapid, automated method for the performance of the Limulus amoebocyte lysate endotoxin assay has been developed by using the Abbott MS-2 Microbiology System. This instrument automatically determines sequential changes in the optical density of up to 176 samples at 1- or 5-min increments during a 1-h assay period. Graphic representation of optical density changes can be viewed on a cathode-ray tube or reproduced by using a hard-copy printer. Limulus amoebocyte lysate preparations that were o...

  8. Abbott Wave-Triggered Runaway in Line-Driven Winds from Stars and Accretion Disks

    Feldmeier, Achim; Shlosman, Isaac

    2001-01-01

    Line-driven winds from stars and accretion disks are accelerated by scattering in numerous line transitions. The wind is believed to adopt a unique critical solution, out of the infinite variety of shallow and steep solutions. We study the inherent dynamics of the transition towards the critical wind. A new runaway wind mechanism is analyzed in terms of radiative-acoustic (Abbott) waves which are responsible for shaping the wind velocity law and fixing the mass loss. Three different flow type...

  9. Demagnetizing effects in stacked rectangular prisms

    Christensen, Dennis; Nielsen, Kaspar Kirstein; Bahl, Christian Robert Haffenden;

    2011-01-01

    configuration, temperature distribution and applied magnetic field. In this paper the model is applied to the case of a stack of parallel, ferromagnetic rectangular prisms and the resulting internal field is found as a function of the orientation of the applied field, the number of prisms in the stack, the...... spacing between the prisms and the packing density of the stack. The results show that the resulting internal field is far from being equal to the applied field and that the various stack configurations investigated affect the resulting internal field significantly and non-linearly. The results have a...

  10. CHR(PRISM)-based probabilistic logic learning

    Sneyers, Jon; Meert, Wannes; Vennekens, Joost; Kameya, Yoshitaka; Sato, Taisuke

    2010-01-01

    PRISM is an extension of Prolog with probabilistic predicates and built-in support for expectation-maximization learning. Constraint Handling Rules (CHR) is a high-level programming language based on multi-headed multiset rewrite rules. In this paper, we introduce a new probabilistic logic formalism, called CHRiSM, based on a combination of CHR and PRISM. It can be used for high-level rapid prototyping of complex statistical models by means of "chance rules". The underlying PRISM system can t...

  11. A prism carbon molecule C$_20$

    OHNO, Koichi; Satoh, Hiroko; Iwamoto, Takeaki

    2015-01-01

    A new carbon family with a prism structure has been found by quantum chemical calculations. The prism-$C_20$ has a $D_10h$ structure with double-layered decagonal rings connected each other by ten vertical CC bonds. The CC bond lengths are 0.144 nm on the decagonal rings and 0.148 nm on the side faces. The diameter of the ring is 0.465 nm. The $prism-C_20$ is expected to be stable, since the lowest energy barrier from it was estimated to be 158.0 kJ mol$^−1$.

  12. Highly dispersive photonic band-gap prism

    We propose the concept of a photonic band-gap (PBG) prism based on two-dimensional PBG structures and realize it in the millimeter-wave spectral regime. We recognize the highly nonlinear dispersion of PBG materials near Brillouin zone edges and utilize the dispersion to achieve strong prism action. Such a PBG prism is very compact if operated in the optical regime, ∼20μm in size for λ∼700nm, and can serve as a dispersive element for building ultracompact miniature spectrometers. copyright 1996 Optical Society of America

  13. Highly dispersive photonic band-gap prism.

    Lin, S Y; Hietala, V M; Wang, L; Jones, E D

    1996-11-01

    We propose the concept of a photonic band-gap (PBG) prism based on two-dimensional PBG structures and realize it in the millimeter-wave spectral regime. We recognize the highly nonlinear dispersion of PBG materials near Brillouin zone edges and utilize the dispersion to achieve strong prism action. Such a PBG prism is very compact if operated in the optical regime, ~20 mm in size for lambda ~ 700 nm, and can serve as a dispersive element for building ultracompact miniature spectrometers. PMID:19881796

  14. Prism: a new approach to radiotherapy planning software

    Purpose: We describe the capabilities and performance of Prism, an innovative new radiotherapy planning system with unusual features and design. The design and implementation strategies are intended to assure high quality and clinical acceptability. The features include Artificial Intelligence tools and special support for multileaf collimator (MLC) systems. The design provides unusual flexibility of operation and ease of expansion. Methods and Materials: We have implemented Prism, a three-dimensional (3D) radiotherapy treatment-planning system on standard commercial workstations with the widely available X window system. The design and implementation use ideas taken from recent software engineering research, for example, the use of behavioral entity-relationship modeling and the 'Mediator Method' instead of ad-hoc programming. The Prism system includes the usual features of a 3D planning system, including Beam's Eye View and the ability to simulate any treatment geometry possible with any standard radiotherapy accelerator. It includes a rule-based expert system for automated generation of the planning target volume as defined in ICRU Report 50. In addition, it provides special support for planning treatments with a multileaf collimator (MLC). We also implemented a Radiotherapy Treatment Planning Tools Foundation for Prism, so that we are able to use software tools from other institutions without any source code modification. Results: The Prism system has been in clinical operation at the University of Washington since July 1994 and has been installed at several other clinics. The system is run simultaneously by several users, each with their own workstation operating from a common networked database and software. In addition to the dosimetrists, the system is used by radiation oncologists to define tumor and target volumes and by radiation therapists to select treatment setups to load into a computer controlled accelerator. Conclusions: Experience with the

  15. 21 CFR 886.1650 - Ophthalmic bar prism.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic bar prism. 886.1650 Section 886.1650...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1650 Ophthalmic bar prism. (a) Identification. An ophthalmic bar prism is a device that is a bar composed of fused prisms of gradually...

  16. Portable Remote Imaging Spectrometer (PRISM) Project

    National Aeronautics and Space Administration — Develop an UV-NIR (350nm to 1050 nm) portable remote imaging spectrometer (PRISM) for flight on a variety of airborne platforms with high SNR and response...

  17. Random prism: an alternative to random forests

    Stahl, F.; Bramer, Max

    2012-01-01

    Ensemble learning techniques generate multiple classifiers, so called base classifiers, whose combined classification results are used in order to increase the overall classification accuracy. In most ensemble classifiers the base classifiers are based on the Top Down Induction of Decision Trees (TDIDT) approach. However, an alternative approach for the induction of rule based classifiers is the Prism family of algorithms. Prism algorithms produce modular classification rules that do not nece...

  18. Pillars and pinning centers in superconducting prisms

    We solve the Ginzburg-Landau equations for to study the vortex configurations in a superconducting prism with a square array of pillars or holes in the presence of a uniform applied magnetic field. The presence of the pillars (holes) changes the vortex structures in the superconducting prism considerably. We calculate magnetization, free energy and vorticity curves, which shows the transition between different vortex configurations as a function of magnetic fields

  19. Recent studies on the PRISM FFAG ring

    Next generation lepton flavour violation experiments require high intensity and high quality muon beams. The PRISM Task Force focuses on accelerator R and D for realizing such beams using an FFAG ring. The scaling and non-scaling designs for the PRISM FFAG ring are discussed. The recent studies on injection/extraction systems and matching to the solenoid channel are outlined. The future plans for the study are presented.

  20. OPERA: Objective Prism Enhanced Reduction Algorithms

    Universidad Complutense de Madrid Astrophysics Research Group

    2015-09-01

    OPERA (Objective Prism Enhanced Reduction Algorithms) automatically analyzes astronomical images using the objective-prism (OP) technique to register thousands of low resolution spectra in large areas. It detects objects in an image, extracts one-dimensional spectra, and identifies the emission line feature. The main advantages of this method are: 1) to avoid subjectivity inherent to visual inspection used in past studies; and 2) the ability to obtain physical parameters without follow-up spectroscopy.

  1. Demagnetizing effects in stacked rectangular prisms

    A numerical, magnetostatic model of the internal magnetic field of a rectangular prism is extended to the case of a stack of rectangular prisms. The model enables the calculation of the spatially resolved, three-dimensional internal field in such a stack given any magnetic state function, stack configuration, temperature distribution and applied magnetic field. In this paper the model is applied to the case of a stack of parallel, ferromagnetic rectangular prisms and the resulting internal field is found as a function of the orientation of the applied field, the number of prisms in the stack, the spacing between the prisms and the packing density of the stack. The results show that the resulting internal field is far from being equal to the applied field and that the various stack configurations investigated affect the resulting internal field significantly and non-linearly. The results have a direct impact on the design of, e.g., active magnetic regenerators made of stacked rectangular prisms in terms of optimizing the internal field.

  2. Neutron energy analysis by silicon prisms

    Neutron energy analysing by refraction with prisms allows to measure different wavelengths at the same time thus avoiding losses due to monochromatization. We built and tested a refractive energy analysing device made from small prisms, where losses only occur due to the attenuation in the material. We measured the refraction and the transmission of MgF2 and Si prisms at the V14 reflectometer in Berlin at 4.9 Å to check their applicability. The experimentally determined linear attenuation coefficients are 0.055 cm−1 for the MgF2 and 0.03 cm−1 for the Si prisms. An energy analyser consisting of silicon prism layers was measured at the EROS reflectometer at the LLB in a white neutron beam. The useful wavelength band was 2.4–7.6 Å. At 6.7 Å a wavelength resolution of 5% and a transmission of 53% were achieved. The surface roughness of the prisms could be determined to be (0.011±0.006)deg

  3. Neutron energy analysis by silicon prisms

    Schulz, J., E-mail: jennifer.schulz@helmholtz-berlin.de [Helmholtz-Zentrum Berlin für Materialien und Energie, Hahn-Meitner-Platz 1, 14109 Berlin (Germany); Ott, F. [Laboratoire Leon Brillouin, Bât 563 CEA Saclay, 91191 Gif sur Yvette Cedex (France); Hülsen, Ch.; Krist, Th. [Helmholtz-Zentrum Berlin für Materialien und Energie, Hahn-Meitner-Platz 1, 14109 Berlin (Germany)

    2013-11-21

    Neutron energy analysing by refraction with prisms allows to measure different wavelengths at the same time thus avoiding losses due to monochromatization. We built and tested a refractive energy analysing device made from small prisms, where losses only occur due to the attenuation in the material. We measured the refraction and the transmission of MgF{sub 2} and Si prisms at the V14 reflectometer in Berlin at 4.9 Å to check their applicability. The experimentally determined linear attenuation coefficients are 0.055 cm{sup −1} for the MgF{sub 2} and 0.03 cm{sup −1} for the Si prisms. An energy analyser consisting of silicon prism layers was measured at the EROS reflectometer at the LLB in a white neutron beam. The useful wavelength band was 2.4–7.6 Å. At 6.7 Å a wavelength resolution of 5% and a transmission of 53% were achieved. The surface roughness of the prisms could be determined to be (0.011±0.006)deg.

  4. A portable direct view configuration prism spectrometer using a double Amici prism

    Sun, Lanjun; Zhang, Yanchao; Tian, Zhaoshuo; Ren, Xiuyun; Fu, Shiyou

    2015-10-01

    In this paper, we present a prism spectrometer that exploits a double Amici prism dispersion structure. The system consists of a slit, a collimating lens, a double Amici prism, an imaging lens and a CCD. The incident light enter into slit, and then is paralleled by a collimating lens to the double Amici prism. The double Amici prism is used to realize spectral dispersion. The dispersed light is collected by an imaging lens and image on the photosensitive surface of the CCD. The dispersion resolution is theoretical analyzed from the ray tracing point of view. In addition, the imaging position on CCD element at different wavelength is presented according to nonlinear curve of dispersion. The designed prism spectrometer can obtain a high light throughput and less optical distortion spectrum in the spectral range of 370-700nm. In experiment, we measured the spectral resolution of the designed prism spectrometer at five wavelength used a grating monochromator. The designed in-line, direct view configuration prism spectrometer owns the advantages of high light throughput, less optical distortions, compact structure, small volume and easy operation, which has important role in application of laser spectral measurement especially laser remote sensing spectral detection.

  5. Subsurface damage distribution characterization of ground surfaces using Abbott-Firestone curves

    Measurement of subsurface damage (SSD) induced by grinding process is of major interest in the development of high laser damage fused silica optical components manufacturing processes. Most SSD measurements methods give only access to the peak to peak value. We herein report on the benefit of using Abbott-Firestone curves to get an insight of the SSD distribution inside the optical material. We evidence on various diamond wheel ground fused silica substrates that such an approach is complementary to a classical SSD peak to peak measurement and bring useful information to optimize a grinding process. (authors)

  6. An improved prism energy analyzer for neutrons

    The effects of two improvements of an existing neutron energy analyzer consisting of stacked silicon prism rows are presented. First we tested the effect of coating the back of the prism rows with an absorbing layer to suppress neutron scattering by total reflection and by refraction at small angles. Experiments at HZB showed that this works perfectly. Second the prism rows were bent to shift the transmitted wavelength band to larger wavelengths. At HZB we showed that bending increased the transmission of neutrons with a wavelength of 4.9 Å. Experiments with a white beam at the EROS reflectometer at LLB showed that bending of the energy analyzing device to a radius of 7.9 m allows to shift the transmitted wavelength band from 0 to 9 Å to 2 to 16 Å

  7. An improved prism energy analyzer for neutrons

    Schulz, J., E-mail: jennifer.schulz@helmholtz-berlin.de [Helmholtz-Zentrum Berlin für Materialien und Energie, Hahn-Meitner-Platz 1, 14109 Berlin (Germany); Ott, F. [Laboratoire Leon Brillouin, Bât 563 CEA Saclay, 91191 Gif sur Yvette Cedex (France); Krist, Th. [Helmholtz-Zentrum Berlin für Materialien und Energie, Hahn-Meitner-Platz 1, 14109 Berlin (Germany)

    2014-04-21

    The effects of two improvements of an existing neutron energy analyzer consisting of stacked silicon prism rows are presented. First we tested the effect of coating the back of the prism rows with an absorbing layer to suppress neutron scattering by total reflection and by refraction at small angles. Experiments at HZB showed that this works perfectly. Second the prism rows were bent to shift the transmitted wavelength band to larger wavelengths. At HZB we showed that bending increased the transmission of neutrons with a wavelength of 4.9 Å. Experiments with a white beam at the EROS reflectometer at LLB showed that bending of the energy analyzing device to a radius of 7.9 m allows to shift the transmitted wavelength band from 0 to 9 Å to 2 to 16 Å.

  8. Multicenter evaluation of the new Abbott Realtime assays for quantitative detection of human immunodeficiency virus type 1 and hepatitis C virus RNA

    M. Schutten (Martin); D. Peters (D.); N. Back (Nicole); A.W. van den Beld (Annewieke); B. Beuselinck (B.); V. Foulongne (V.); A.M. Geretti (Anna Maria); L. Pandiani (L.); M. Tiemann; H.G.M. Niesters (Bert)

    2007-01-01

    textabstractThe analytical performances of the new Abbott RealTime hepatitis C virus (HCV) and human immunodeficiency virus type 1 viral load assays were compared at nine laboratories with different competitor assays. These included the Abbott LcX, Bayer Versant bDNA, Roche COBAS Amplicor, and Roche

  9. Multicenter evaluation of the new Abbott RealTime assays for quantitative detection of human immunodeficiency virus type 1 and hepatitis C virus RNA

    Schutten, M; Peters, D; Back, N K T; Beld, M; Beuselinck, K; Foulongne, V; Geretti, A-M; Pandiani, L; Tiemann, C; Niesters, H G M

    2007-01-01

    The analytical performances of the new Abbott RealTime hepatitis C virus (HCV) and human immunodeficiency virus type 1 viral load assays were compared at nine laboratories with different competitor assays. These included the Abbott LcX, Bayer Versant bDNA, Roche COBAS Amplicor, and Roche COBAS TaqMa

  10. Abbott Wave-Triggered Runaway in Line-Driven Winds from Stars and Accretion Disks

    Feldmeier, A; Feldmeier, Achim; Shlosman, Isaac

    2001-01-01

    Line-driven winds from stars and accretion disks are accelerated by scattering in numerous line transitions. The wind is believed to adopt a unique critical solution, out of the infinite variety of shallow and steep solutions. We study the inherent dynamics of the transition towards the critical wind. A new runaway wind mechanism is analyzed in terms of radiative-acoustic (Abbott) waves which are responsible for shaping the wind velocity law and fixing the mass loss. Three different flow types result, depending on the location of perturbations. First, if the shallow solution is perturbed sufficiently far downstream, a single critical point forms in the flow, which is a barrier for Abbott waves, and the solution tends to the critical one. Second, if the shallow solution is perturbed upstream from this critical point, mass overloading results, and the critical point is shifted inwards. This wind exhibits a broad, stationary region of decelerating flow and its velocity law has kinks. Third, for perturbations eve...

  11. Fresnel Prism on Hess Screen Test

    Kyung Min Koh; Ungsoo Samuel Kim

    2013-01-01

    A 65-year-old male patient complained of diplopia after a cataract surgery. He had esotropia of 18 prism diopters (PDs) at distant and near deviation, and therefore, we performed the Hess screen test to identify any abnormal eye movement. However, the indicator was found to be out of bounds, and therefore, the test could not be completed. Therefore, the test was subsequently performed with a 20 PD base-out Fresnel prism, and an abduction deficit was observed in the right eye, but not in the l...

  12. Running Linux

    Dalheimer, Matthias Kalle

    2006-01-01

    The fifth edition of Running Linux is greatly expanded, reflecting the maturity of the operating system and the teeming wealth of software available for it. Hot consumer topics such as audio and video playback applications, groupware functionality, and spam filtering are covered, along with the basics in configuration and management that always made the book popular.

  13. RUN COORDINATION

    C. Delaere

    2013-01-01

    Since the LHC ceased operations in February, a lot has been going on at Point 5, and Run Coordination continues to monitor closely the advance of maintenance and upgrade activities. In the last months, the Pixel detector was extracted and is now stored in the pixel lab in SX5; the beam pipe has been removed and ME1/1 removal has started. We regained access to the vactank and some work on the RBX of HB has started. Since mid-June, electricity and cooling are back in S1 and S2, allowing us to turn equipment back on, at least during the day. 24/7 shifts are not foreseen in the next weeks, and safety tours are mandatory to keep equipment on overnight, but re-commissioning activities are slowly being resumed. Given the (slight) delays accumulated in LS1, it was decided to merge the two global runs initially foreseen into a single exercise during the week of 4 November 2013. The aim of the global run is to check that we can run (parts of) CMS after several months switched off, with the new VME PCs installed, th...

  14. Symmetry Breaking Analysis of Prism Adaptation's Latent Aftereffect

    Frank, Till D.; Blau, Julia J. C.; Turvey, Michael T.

    2012-01-01

    The effect of prism adaptation on movement is typically reduced when the movement at test (prisms off) differs on some dimension from the movement at training (prisms on). Some adaptation is latent, however, and only revealed through further testing in which the movement at training is fully reinstated. Applying a nonlinear attractor dynamic model…

  15. 21 CFR 886.1655 - Ophthalmic Fresnel prism.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic Fresnel prism. 886.1655 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1655 Ophthalmic Fresnel prism. (a) Identification. An ophthalmic Fresnel prism is a device that is a thin plastic sheet with embossed rulings...

  16. 21 CFR 886.1665 - Ophthalmic rotary prism.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic rotary prism. 886.1665 Section 886.1665...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1665 Ophthalmic rotary prism. (a) Identification. An ophthalmic rotary prism is a device with various prismatic powers intended to be handheld...

  17. 21 CFR 886.5810 - Ophthalmic prism reader.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic prism reader. 886.5810 Section 886.5810...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5810 Ophthalmic prism reader. (a) Identification. An ophthalmic prism reader is a device intended for use by a patient who is in a supine...

  18. Dispersion Compensation with a Prism-pair

    Shaked, Yaakov; Pe'er, Avi

    2014-01-01

    We present a detailed calculation of the total dispersion (spectral phase) from a pair of Brewster-cut prisms. This paper aims to aid advanced students in tracking the operation of this major configuration for dispersion-compensation and phase-control of ultra-short pulses.

  19. Comparing the Volumes of Rectangular Prisms

    Assuah, Charles K.; Wiest, Lynda R.

    2010-01-01

    Can middle-grades students determine which of two rectangular prisms has a larger volume? Can they do so without using a formula? Geometry, and particularly the concept of volume, is important in many subjects, such as physics and chemistry. Students greatly enhance their mathematics knowledge when they make generalizations and construct arguments…

  20. Prisms Throw Light on Developmental Disorders

    Brookes, Rebecca L.; Nicolson, Roderick I.; Fawcett, Angela J.

    2007-01-01

    Prism adaptation, in which the participant adapts to prismatic glasses that deflect vision laterally, is a specific test of cerebellar function. Fourteen dyslexic children (mean age 13.5 years); 14 children with developmental coordination disorder (DCD): 6 of whom had comorbid dyslexia; and 12 control children matched for age and IQ underwent…

  1. CHR(PRISM)-based Probabilistic Logic Learning

    Sneyers, Jon; Vennekens, Joost; Kameya, Yoshitaka; Sato, Taisuke; 10.1017/S1471068410000207

    2010-01-01

    PRISM is an extension of Prolog with probabilistic predicates and built-in support for expectation-maximization learning. Constraint Handling Rules (CHR) is a high-level programming language based on multi-headed multiset rewrite rules. In this paper, we introduce a new probabilistic logic formalism, called CHRiSM, based on a combination of CHR and PRISM. It can be used for high-level rapid prototyping of complex statistical models by means of "chance rules". The underlying PRISM system can then be used for several probabilistic inference tasks, including probability computation and parameter learning. We define the CHRiSM language in terms of syntax and operational semantics, and illustrate it with examples. We define the notion of ambiguous programs and define a distribution semantics for unambiguous programs. Next, we describe an implementation of CHRiSM, based on CHR(PRISM). We discuss the relation between CHRiSM and other probabilistic logic programming languages, in particular PCHR. Finally we identify ...

  2. Development and application of GIS-based PRISM integration through a plugin approach

    Lee, Woo-Seop; Chun, Jong Ahn; Kang, Kwangmin

    2014-05-01

    A PRISM (Parameter-elevation Regressions on Independent Slopes Model) QGIS-plugin was developed on Quantum GIS platform in this study. This Quantum GIS plugin system provides user-friendly graphic user interfaces (GUIs) so that users can obtain gridded meteorological data of high resolutions (1 km × 1 km). Also, this software is designed to run on a personal computer so that it does not require an internet access or a sophisticated computer system. This module is a user-friendly system that a user can generate PRISM data with ease. The proposed PRISM QGIS-plugin is a hybrid statistical-geographic model system that uses coarse resolution datasets (APHRODITE datasets in this study) with digital elevation data to generate the fine-resolution gridded precipitation. To validate the performance of the software, Prek Thnot River Basin in Kandal, Cambodia is selected for application. Overall statistical analysis shows promising outputs generated by the proposed plugin. Error measures such as RMSE (Root Mean Square Error) and MAPE (Mean Absolute Percentage Error) were used to evaluate the performance of the developed PRISM QGIS-plugin. Evaluation results using RMSE and MAPE were 2.76 mm and 4.2%, respectively. This study suggested that the plugin can be used to generate high resolution precipitation datasets for hydrological and climatological studies at a watershed where observed weather datasets are limited.

  3. Repo Runs

    Antoine Martin; David Skeie; Ernst-Ludig von Thadden

    2011-01-01

    This paper develops a dynamic model of financial institutions that borrow short-term and invest into long-term marketable assets. Because such intermediaries performmaturity transformation, they are subject to potential runs. We derive distinct liquidity and collateral constraints that characterize the fragility of such institutions as a result of changing market expectations. The liquidity constraint depends on the intermediary’s endogenous liquidity position that acts as a buffer against ru...

  4. Running Club

    Running Club

    2011-01-01

    The cross country running season has started well this autumn with two events: the traditional CERN Road Race organized by the Running Club, which took place on Tuesday 5th October, followed by the ‘Cross Interentreprises’, a team event at the Evaux Sports Center, which took place on Saturday 8th October. The participation at the CERN Road Race was slightly down on last year, with 65 runners, however the participants maintained the tradition of a competitive yet friendly atmosphere. An ample supply of refreshments before the prize giving was appreciated by all after the race. Many thanks to all the runners and volunteers who ensured another successful race. The results can be found here: https://espace.cern.ch/Running-Club/default.aspx CERN participated successfully at the cross interentreprises with very good results. The teams succeeded in obtaining 2nd and 6th place in the Mens category, and 2nd place in the Mixed category. Congratulations to all. See results here: http://www.c...

  5. RUN COORDINATION

    Christophe Delaere

    2013-01-01

    The focus of Run Coordination during LS1 is to monitor closely the advance of maintenance and upgrade activities, to smooth interactions between subsystems and to ensure that all are ready in time to resume operations in 2015 with a fully calibrated and understood detector. After electricity and cooling were restored to all equipment, at about the time of the last CMS week, recommissioning activities were resumed for all subsystems. On 7 October, DCS shifts began 24/7 to allow subsystems to remain on to facilitate operations. That culminated with the Global Run in November (GriN), which   took place as scheduled during the week of 4 November. The GriN has been the first centrally managed operation since the beginning of LS1, and involved all subdetectors but the Pixel Tracker presently in a lab upstairs. All nights were therefore dedicated to long stable runs with as many subdetectors as possible. Among the many achievements in that week, three items may be highlighted. First, the Strip...

  6. running ocean

    Lokenath Debnath

    1978-01-01

    Full Text Available A theory is presented of the generation and propagation of the two and the three dimensional tsunamis in a shallow running ocean due to the action of an arbitrary ocean floor or ocean surface disturbance. Integral solutions for both two and three dimensional problems are obtained by using the generalized Fourier and Laplace transforms. An asymptotic analysis is carried out for the investigation of the principal features of the free surface elevation. It is found that the propagation of the tsunamis depends on the relative magnitude of the given speed of the running ocean and the wave speed of the shallow ocean. When the speed of the running ocean is less than the speed of the shallow ocean wave, both the two and the three dimensional free surface elevation represent the generation and propagation of surface waves which decay asymptotically as t−12 for the two dimensional case and as t−1 for the three dimensional tsunamis. Several important features of the solution are discussed in some detail. As an application of the general theory, some physically realistic ocean floor disturbances are included in this paper.

  7. RUN COORDINATION

    M. Chamizo

    2012-01-01

      On 17th January, as soon as the services were restored after the technical stop, sub-systems started powering on. Since then, we have been running 24/7 with reduced shift crew — Shift Leader and DCS shifter — to allow sub-detectors to perform calibration, noise studies, test software upgrades, etc. On 15th and 16th February, we had the first Mid-Week Global Run (MWGR) with the participation of most sub-systems. The aim was to bring CMS back to operation and to ensure that we could run after the winter shutdown. All sub-systems participated in the readout and the trigger was provided by a fraction of the muon systems (CSC and the central RPC wheel). The calorimeter triggers were not available due to work on the optical link system. Initial checks of different distributions from Pixels, Strips, and CSC confirmed things look all right (signal/noise, number of tracks, phi distribution…). High-rate tests were done to test the new CSC firmware to cure the low efficiency ...

  8. Self-referenced prism deflection measurement schemes with microradian precision

    Olson, R; Bergeson, S; Durfee, D S; Olson, Rebecca; Paul, Justin; Bergeson, Scott; Durfee, Dallin S.

    2005-01-01

    We have demonstrated several inexpensive methods which can be used to measure the deflection angles of prisms with microradian precision. The methods are self-referenced, using various reversals to achieve absolute measurements without the need of a reference prism or any expensive precision components other than the prisms under test. These techniques are based on laser interferometry and have been used in our lab to characterize parallel-plate beamsplitters, penta prisms, right angle prisms, and corner cube reflectors using only components typically available in an optics lab.

  9. Abbott AXSYM免疫分析仪几种节约试剂方法

    徐忠玉; 梁声强; 邓小军

    2006-01-01

    Abbott AXSYM免疫分析仪是目前比较理想的全自动免疫分析仪器,但该仪器所用的试剂昂贵也是实际。因此如何在不影响检测结果的基础上,节约成本、减少浪费是值得关注的问题。我们在使用过程中,摸索和总结了几种节约试剂用量和利用剩余试剂的方法,现介绍如下,供参考。

  10. 美国Abbott Axsym免疫分析仪性能初步评价

    成军; 袁兴旺; 金晶; 王国政; 孙长贵; 孙关忠

    2003-01-01

    @@ 随着国内临床免疫学实验室自动化程度的不断提高,全自动免疫分析仪逐步得到普及和应用[1],本文以检测乙型肝炎病毒表面抗原(HBsAg)为例,对美国Abbott Axsym免疫分析仪微粒子酶免疫分析(MEIA)技术的灵敏度、可检测性、特异性、重复性、线性、干扰试验及与酶联免疫吸附试验(ELISA)检测HBsAg的相关性等指标进行了检测,以评价其性能.

  11. 巧用AbbottC8000的Retest功能进行试剂比对

    刘风华

    2013-01-01

    目的通过AbbottC8000本身具有的“RetestRule”功能进行试剂间的比对,观察同一仪器同一项目不同试剂间的检测结果是否具有可比性。方法在Abbott(;8000上调试同一项目两种试剂(bun)参数,并设定“RetestRule”。结果通过对比对数据的统计学分析,得到两系统间相关性良好,R2=0.9991。结论运用Ab—bottC8000的“RetestRule”功能可以简便、快捷的完成比对实验,值得推广。

  12. Performance of the new automated Abbott RealTime MTB assay for rapid detection of Mycobacterium tuberculosis complex in respiratory specimens.

    Chen, J H K; She, K K K; Kwong, T-C; Wong, O-Y; Siu, G K H; Leung, C-C; Chang, K-C; Tam, C-M; Ho, P-L; Cheng, V C C; Yuen, K-Y; Yam, W-C

    2015-09-01

    The automated high-throughput Abbott RealTime MTB real-time PCR assay has been recently launched for Mycobacterium tuberculosis complex (MTBC) clinical diagnosis. This study would like to evaluate its performance. We first compared its diagnostic performance with the Roche Cobas TaqMan MTB assay on 214 clinical respiratory specimens. Prospective analysis of a total 520 specimens was then performed to further evaluate the Abbott assay. The Abbott assay showed a lower limit of detection at 22.5 AFB/ml, which was more sensitive than the Cobas assay (167.5 AFB/ml). The two assays demonstrated a significant difference in diagnostic performance (McNemar's test; P = 0.0034), in which the Abbott assay presented significantly higher area under curve (AUC) than the Cobas assay (1.000 vs 0.880; P = 0.0002). The Abbott assay demonstrated extremely low PCR inhibition on clinical respiratory specimens. The automated Abbott assay required only very short manual handling time (0.5 h), which could help to improve the laboratory management. In the prospective analysis, the overall estimates for sensitivity and specificity of the Abbott assay were both 100 % among smear-positive specimens, whereas the smear-negative specimens were 96.7 and 96.1 %, respectively. No cross-reactivity with non-tuberculosis mycobacterial species was observed. The superiority in sensitivity of the Abbott assay for detecting MTBC in smear-negative specimens could further minimize the risk in MTBC false-negative detection. The new Abbott RealTime MTB assay has good diagnostic performance which can be a useful diagnostic tool for rapid MTBC detection in clinical laboratories. PMID:26071001

  13. Prioritization Risk Integration Simulation Model (PRISM) For Environmental Remediation and Waste Management - 12097

    and performance assessment calculations. PRISM can be run in a deterministic mode, which quickly provides an estimate of the most likely results of a given plan. Alternatively, the model can be run probabilistically in a Monte Carlo mode, exploring the risks and uncertainties in the system and producing probability distributions for the different performance measures. The PRISM model demonstrates how EM can evaluate a portfolio of ELOs, and transform the ELOs from their current conditions to acceptable conditions, utilizing different strategic approaches. There are many types of ELOs - contaminated soils and groundwater plumes, disused facilities awaiting D and D, and various types of wastes waiting for processing or disposal. This scope of work for the PRISM process and the development of a dynamic simulation model are a logical extension of the GoldSim simulation software used by the OCRWM to assess the long-term performance for the Yucca Mountain Project and by NNSA to assess project risk at its sites. Systems integration modeling will promote better understanding of all project risks, technical and nontechnical, and more defensible decision-making for complex projects with significant uncertainties. It can provide effective visual communication and rapid adaptation during interactions with stakeholders (Administration, Congress, State, Local, and NGO). It will also allow rapid assessment of alternative management approaches. (authors)

  14. RUN COORDINATION

    G. Rakness.

    2013-01-01

    After three years of running, in February 2013 the era of sub-10-TeV LHC collisions drew to an end. Recall, the 2012 run had been extended by about three months to achieve the full complement of high-energy and heavy-ion physics goals prior to the start of Long Shutdown 1 (LS1), which is now underway. The LHC performance during these exciting years was excellent, delivering a total of 23.3 fb–1 of proton-proton collisions at a centre-of-mass energy of 8 TeV, 6.2 fb–1 at 7 TeV, and 5.5 pb–1 at 2.76 TeV. They also delivered 170 μb–1 lead-lead collisions at 2.76 TeV/nucleon and 32 nb–1 proton-lead collisions at 5 TeV/nucleon. During these years the CMS operations teams and shift crews made tremendous strides to commission the detector, repeatedly stepping up to meet the challenges at every increase of instantaneous luminosity and energy. Although it does not fully cover the achievements of the teams, a way to quantify their success is the fact that that...

  15. Deborah Abbott: Out in the Redwoods, Documenting Gay, Lesbian, Bisexual, Transgender History at the University of California, SAnta Cruz, 1965-2003

    Reti, Irene H.; Brashear, Regan; Abbott, Deborah

    2004-01-01

    Deborah Abbott is a writer, health activist, teacher, river guide and current director of the Gay, Lesbian, Bisexual and Transgender Resource Center at UCSC. Since assuming her position in November of 1997, she has given new shape and direction to the Center. As an American studies major, I was eager to interview  Deb Abbott. Deb Abbott to learn more about the queer history of UCSC, as well as about her work within two local feminist health organizations: the Santa Cruz Women's Health Collect...

  16. Multivariable control for the PRISM ALMR

    This paper describes the application of state variable control design methods in the conceptual design of two key system level controllers in the PRISM ALMR. The PRISM plant concept consists of three power blocks, each made up of three identical reactors and steam generator modules connected to one turbine. Operation of these physically distributed systems is directed by a hierarchy of controllers at the system, power block, and plant levels. The system level controllers in this paper are the reactivity controllers for movement of the six control rods in each of the nine reactor modules, and the feedwater control of the three parallel steam generators in each of the three power blocks. 4 refs., 6 figs., 1 tab

  17. Risley prism universal pointing system (RPUPS)

    Dixon, John; Engel, James R.; Vaillancourt, Robert; Schwarze, Craig; Potter, Kevin

    2015-09-01

    OPTRA is currently developing a Risley Prism Universal Pointing System (RPUPS): a highly customizable cued beamsteering system. The RPUPS consists of a visible or infrared cueing imager co-aligned with an optical beam steering system's pointing-field-of-regard. The cueing imager is used to identify a region-of-interest within its wide field-of-view, via a wireless tablet device. The tablet user can choose to manually or automatically, identify and track regions-of-interest. The optical beam steering system uses a matched pair of Risley Prisms to direct an interrogating optical system's instantaneous-field-of-view onto the identified region-of-interest. The tablet updates the user with real time information from both the cueing imager and the interrogating optical system. Risley prism material and geometry choices provide operating wavelength, aperture size, and field-of-regard flexibility for this front-end pointing component. Back-end components may be receive-only, transmit-only, or transmit/receive combinations. The flexibility of the RPUPS allows for mission specific customization where applications include but are not limited to: synthetic foveated imaging, spectroscopic probes and laser (LIDAR) ranging and tracking. This paper will focus on the design and anticipated applications of the RPUPS.

  18. Evaluations of 1990 PRISM design revisions

    Analyses of the 1990 version of the PRISM Advanced Liquid Metal Reactor (ALMR) design are presented and discussed. Most of the calculations were performed using BNL computer codes, particularly SSC and MINET. In many cases, independent BNL calculations were compared against analyses presented by General Electric when they submitted the PRISM design revisions for evaluation by the Nuclear Regulatory Commission (NRC). The current PRISM design utilizes the metallic fuel developed by Argonne National Laboratory (ANL) which facilitates the passive/''inherent'' shutdown mechanism that acts to shut down reactor power production whenever the system overheats. There are a few vulnerabilities in the passive shutdown, with the most worrisome being the positive feedback from sodium density decreases or sodium voiding. Various postulated unscrammed events were examined by GE and/or BNL, and much of the analysis discussed in this report is focused on this category of events. For the most part, the BNL evaluations confirm the information submitted by General Electric. The principal areas of concern are related to the performance of the ternary metal fuel, and may be resolved as ANL continues with its fuel development and testing program

  19. Evaluations of 1990 PRISM design revisions

    Van Tuyle, G.J.; Slovik, G.C.; Chan, B.C.; Aronson, A.L.; Kennett, R.J. [Brookhaven National Lab., Upton, NY (United States)

    1992-03-01

    Analyses of the 1990 version of the PRISM Advanced Liquid Metal Reactor (ALMR) design are presented and discussed. Most of the calculations were performed using BNL computer codes, particularly SSC and MINET. In many cases, independent BNL calculations were compared against analyses presented by General Electric when they submitted the PRISM design revisions for evaluation by the Nuclear Regulatory Commission (NRC). The current PRISM design utilizes the metallic fuel developed by Argonne National Laboratory (ANL) which facilitates the passive/``inherent`` shutdown mechanism that acts to shut down reactor power production whenever the system overheats. There are a few vulnerabilities in the passive shutdown, with the most worrisome being the positive feedback from sodium density decreases or sodium voiding. Various postulated unscrammed events were examined by GE and/or BNL, and much of the analysis discussed in this report is focused on this category of events. For the most part, the BNL evaluations confirm the information submitted by General Electric. The principal areas of concern are related to the performance of the ternary metal fuel, and may be resolved as ANL continues with its fuel development and testing program.

  20. Impact of the New Abbott mPLUS Feature on Clinical Laboratory Efficiencies of Abbott RealTime Assays for Detection of HIV-1, Hepatitis C Virus, Hepatitis B Virus, Chlamydia trachomatis, and Neisseria gonorrhoeae

    Lucic, Danijela; Jones, Sara; Wiesneth, Russ; Barry, Cathy; Webb, Erika; Belova, Larissa; Dolan, Peggy; Ho, Shiaolan; Abravaya, Klara; Cloherty, Gavin

    2013-01-01

    Diagnostic laboratories are under increasing pressure to improve and expand their services. Greater flexibility in sample processing is a critical factor that can improve the time to results while reducing reagent waste, making laboratories more efficient and cost-effective. The introduction of the Abbott mPLUS feature, with the capacity for extended use of amplification reagents, significantly increases the flexibility of the m2000 platform and enables laboratories to customize their workflo...

  1. RUN COORDINATION

    Christophe Delaere

    2012-01-01

      On Wednesday 14 March, the machine group successfully injected beams into LHC for the first time this year. Within 48 hours they managed to ramp the beams to 4 TeV and proceeded to squeeze to β*=0.6m, settings that are used routinely since then. This brought to an end the CMS Cosmic Run at ~Four Tesla (CRAFT), during which we collected 800k cosmic ray events with a track crossing the central Tracker. That sample has been since then topped up to two million, allowing further refinements of the Tracker Alignment. The LHC started delivering the first collisions on 5 April with two bunches colliding in CMS, giving a pile-up of ~27 interactions per crossing at the beginning of the fill. Since then the machine has increased the number of colliding bunches to reach 1380 bunches and peak instantaneous luminosities around 6.5E33 at the beginning of fills. The average bunch charges reached ~1.5E11 protons per bunch which results in an initial pile-up of ~30 interactions per crossing. During the ...

  2. RUN COORDINATION

    C. Delaere

    2012-01-01

      With the analysis of the first 5 fb–1 culminating in the announcement of the observation of a new particle with mass of around 126 GeV/c2, the CERN directorate decided to extend the LHC run until February 2013. This adds three months to the original schedule. Since then the LHC has continued to perform extremely well, and the total luminosity delivered so far this year is 22 fb–1. CMS also continues to perform excellently, recording data with efficiency higher than 95% for fills with the magnetic field at nominal value. The highest instantaneous luminosity achieved by LHC to date is 7.6x1033 cm–2s–1, which translates into 35 interactions per crossing. On the CMS side there has been a lot of work to handle these extreme conditions, such as a new DAQ computer farm and trigger menus to handle the pile-up, automation of recovery procedures to minimise the lost luminosity, better training for the shift crews, etc. We did suffer from a couple of infrastructure ...

  3. Running Club

    Running Club

    2010-01-01

    The 2010 edition of the annual CERN Road Race will be held on Wednesday 29th September at 18h. The 5.5km race takes place over 3 laps of a 1.8 km circuit in the West Area of the Meyrin site, and is open to everyone working at CERN and their families. There are runners of all speeds, with times ranging from under 17 to over 34 minutes, and the race is run on a handicap basis, by staggering the starting times so that (in theory) all runners finish together. Children (< 15 years) have their own race over 1 lap of 1.8km. As usual, there will be a “best family” challenge (judged on best parent + best child). Trophies are awarded in the usual men’s, women’s and veterans’ categories, and there is a challenge for the best age/performance. Every adult will receive a souvenir prize, financed by a registration fee of 10 CHF. Children enter free (each child will receive a medal). More information, and the online entry form, can be found at http://cern.ch/club...

  4. PRogram In Support of Moms (PRISM): Development and Beta Testing.

    Byatt, Nancy; Pbert, Lori; Hosein, Safiyah; Swartz, Holly A; Weinreb, Linda; Allison, Jeroan; Ziedonis, Douglas

    2016-08-01

    Most women with perinatal depression do not receive depression treatment. The authors describe the development and beta testing of a new program, PRogram In Support of Moms (PRISM), to improve treatment of perinatal depression in obstetric practices. A multidisciplinary work group of seven perinatal and behavioral health professionals was convened to design, refine, and beta-test PRISM in an obstetric practice. Iterative feedback and problem solving facilitated development of PRISM components, which include provider training and a toolkit, screening procedures, implementation assistance, and access to immediate psychiatric consultation. Beta testing with 50 patients over two months demonstrated feasibility and suggested that PRISM may improve provider screening rates and self-efficacy to address depression. On the basis of lessons learned, PRISM will be enhanced to integrate proactive patient engagement and monitoring into obstetric practices. PRISM may help overcome patient-, provider-, and system-level barriers to managing perinatal depression in obstetric settings. PMID:27079994

  5. Collaborative evaluation of the Abbott Avantage system for identification of frequently isolated nonfermentative or oxidase-positive gram-negative bacilli.

    Jorgensen, J H; Dyke, J W; Helgeson, N G; Cooper, B. H.; Redding, J S; Crawford, S. A.; Andruszewski, M T; Prowant, S A

    1984-01-01

    The capability of the Abbott Avantage system to identify 10 species of commonly isolated glucose nonfermentative or oxidase-positive gram-negative bacilli in a 5-h test period was evaluated in a collaborative study. The Avantage nonenteric data base uses 20 biochemical test reactions performed in an expanded Abbott bacterial identification cartridge plus the results of a manual oxidase test. The species included in the Avantage data base are Acinetobacter anitratus, Acinetobacter Iwoffi, Aero...

  6. Minimal residual HIV viremia: verification of the Abbott Real-Time HIV-1 assay sensitivity

    Alessandra Amendola

    2010-06-01

    Full Text Available Introduction: In the HIV-1 infection, the increase in number of CD4 T lymphocytes and the viral load decline are the main indicators of the effectiveness of antiretroviral therapy. On average, 85% of patients receiving effective treatment has a persistent suppression of plasma viral load below the detection limit (<50 copies/mL of clinically used viral load assays, regardless of treatment regimen in use. It is known, however, that, even when viremia is reduced below the sensitivity limit of current diagnostic assays, the virus persists in “reservoirs” and traces of free virions can be detected in plasma.There is a considerable interest to investigate the clinical significance of residual viremia. Advances in molecular diagnostics allows nowadays to couple a wide dynamic range to a high sensitivity.The Abbott Real-time HIV-1 test is linear from 40 to 107 copies/mL and provides, below 40 copies/mL, additional information such as “<40cp/mL, target detected” or “target not detected”. The HIV-1 detection is verified by the max-Ratio algorithm software.We assessed the test sensitivity when the qualitative response is considered as well. Methods: A ‘probit’ analysis was performed using dilutions of the HIV-1 RNA Working Reagent 1 for NAT assays (NIBSC code: 99/634, defined in IU/mL and different from that used by the manufacturer (VQA,Virology Quality Assurance Laboratory of the AIDS Clinical Trial Group for standardization and definition of performances.The sample input volume (0.6 mL was the same used in clinical routine. A total of 196 replicates at concentrations decreasing from 120 to 5 copies/mL, in three different sessions, have been tested.The ‘probit’ analysis (binomial dose-response model, 95% “hit-rate” has been carried out on the SAS 9.1.3 software package. Results: The sensitivity of the “<40cp/mL, target detected” response was equal to 28,76 copies/mL, with 95% confidence limits between 22,19 and 52,27 copies

  7. Performance of the Abbott RealTime CT/NG for Detection of Chlamydia trachomatis and Neisseria gonorrhoeae▿

    Gaydos, C A; Cartwright, C P; Colaninno, P.; Welsch, J.; Holden, J; Ho, S. Y.; Webb, E. M.; Anderson, C.; Bertuzis, R.; Zhang, L.; Miller, T; Leckie, G.; Abravaya, K.; Robinson, J.

    2010-01-01

    A multicenter clinical study was conducted to evaluate the performance characteristics of the Abbott RealTime CT/NG assay, a multiplex real-time PCR assay, for simultaneous detection of Chlamydia trachomatis and Neisseria gonorrhoeae. The specimens were collected from a total of 3,832 male and female subjects at 16 geographically diverse sites. Specimens included male and female urine samples, male urethral swabs, female endocervical swabs, and self-collected and clinician-collected vaginal s...

  8. Evaluation of the Abbott LCx Mycobacterium tuberculosis Assay for Direct Detection of Mycobacterium tuberculosis Complex in Human Samples

    Garrino, M. G.; Glupczynski, Gerald; Degraux, J; Nizet, H; Delmée, Michel

    1999-01-01

    Seven hundred thirty-seven clinical samples from 460 patients were processed for direct detection of Mycobacterium tuberculosis complex by a semiautomated ligase chain reaction commercial assay, the LCx Mycobacterium tuberculosis Assay (LCx assay) from Abbott Laboratories. Results were compared to those of direct microscopy and standard microbiological culture. Of 26 patients (5.7%) with a culture positive for M. tuberculosis, 22 (84.6%) were found positive by the LCx assay. The sensitivity o...

  9. Evaluation of an Automated Liquid-Handling System (Tecan Genesis RSP 100) in the Abbott LCx Assay for Chlamydia trachomatis

    Hanson, Kevan L.; Cartwright, Charles P.

    2001-01-01

    The present study investigated the feasibility of automating the specimen-pipetting component of sample preparation in the LCx Chlamydia assay (LCx-CT assay; Abbott Laboratories, Chicago, Ill.) by using a commercially available liquid-handling system (Tecan Genesis RSP100; Tecan Inc., Research Triangle Park, N.C.). The Tecan instrument proved to be comparable in both precision and accuracy to a manual multipipettor (Eppendorf model 4850; Eppendorf Scientific, Westbury, N.Y.). The Tecan instru...

  10. Pure rotation of a prism on a ramp

    Zhao, Zhen; Liu, Caishan; Ma, Daolin

    2014-01-01

    In this work, we study a prism with a cross section in polygon rolling on a ramp inclined at a small angle. The prism under gravity rolls purely around each individual edge, intermittently interrupted by a sequence of face collisions between the side face of the prism and the ramp. By limiting the prism in a planar motion, we propose a mathematical model to deal with the events of the impacts. With a pair of laser-Doppler vibrometers, experiments are also conducted to measure the motions of v...

  11. Wollaston prism phase-stepping point diffraction interferometer and method

    Rushford, Michael C.

    2004-10-12

    A Wollaston prism phase-stepping point diffraction interferometer for testing a test optic. The Wollaston prism shears light into reference and signal beams, and provides phase stepping at increased accuracy by translating the Wollaston prism in a lateral direction with respect to the optical path. The reference beam produced by the Wollaston prism is directed through a pinhole of a diaphragm to produce a perfect spherical reference wave. The spherical reference wave is recombined with the signal beam to produce an interference fringe pattern of greater accuracy.

  12. A 1-Diopter Vertical Prism Induces a Decrease of Head Rotation: A Pilot Investigation

    Matheron, Eric; Zandi, Ava; Wang, Danping; Kapoula, Zoï

    2016-01-01

    Clinical studies in non-specific chronic arthralgia and back pain seem to indicate an association between vertical heterophoria (VH – latent vertical retinal misalignment) and asymmetrical head rotation. Such clinical observations suggest a link between VH and head rotation, but this was never tested. The purpose of this study was to simulate a VH in healthy subjects and examine its influence on the amplitude of active head rotation during 3D motion capture in upright stance. Subjects were asked to rotate their head three times from the straight ahead position and then to the right, back to straight ahead, to the left, and back to the straight ahead again. Three randomized conditions were run: normal viewing, with a 1-diopter prism base down on the dominant eye, or the non-dominant eye. The most important finding is that the experimental VH whichever the eye with the prism induces a significant decrease in the mean angle of head rotation compared to the normal viewing condition. This decrease was significant for rotation to the left. We suggest that the prism-induced VH modifies the reference posture and thereby affects head rotation; further studies are needed to confirm this effect and to extend to other types of dynamic activities. PMID:27199886

  13. Inherent safety and design certification of PRISM

    General Electric Company has introduced an innovative technological approach to reactor design that, when combined with change in US Nuclear Regulatory Commission (NRC) practice, will lead to safe and economically competitive fast breeder reactor electric power plants. The key elements in this approach are characteristics in the reactor that will cause it to passively control reactivity and shutdown and passively cool itself without action by the human operators or active devices that require energy supplies external to the reactor module. These characteristics have been called the inherent features or the inherency of the design. They are inherent because they depend on only the material and geometric properties of the reactor module design. Thermal expansion and deflections as well as temperature dependent nuclear properties, such as the Doppler effect, are examples of inherent behavior. Natural convection due to density differences in fluid coolant paths is another example. These characteristics do not depend on active devices that require external energy supplies. PRISM uses natural circulation cooling for safety grade decay heat removal. Negative reactivity feedback with increasing temperature will balance the power generated with the heat removed. The PRISM also incorporates a factory fabricated containment barrier that encloses the reactor and primary coolant. The reactor module design is being developed so that the inherent characteristics of the reactor module can be tested in a full scale prototype. Results from this testing along with other safety and design information will be used to obtain NRC Design Certification

  14. The Variprism: A Large-Range Variable Prism for Measurement of the Angle of Squint

    Simonsz, Huib

    1988-01-01

    textabstractPrism bars and variable Herschel prisms are most commonly used today to measure the angle of squint. Both have drawbacks, however. Prism bars are too large to carry around all day and are usually limited to 40 prism diopters (PD), while variable Herschel prisms have even smaller ranges. Hans Meester and I have therefore developed, at the Netherlands Ophthalmic Research Institute, Amsterdam, a hand-held prism that is continuously variable over a large range, horizontally as well as...

  15. Identifying Codes in the Complementary Prism of Cycles

    Cappelle, Marcia R.; Coelho, Erika M. M.; Coelho, Hebert; Penso, Lucia D.; Rautenbach, Dieter

    2015-01-01

    We show that an identifying code of minimum order in the complementary prism of a cycle of order $n$ has order $7n/9+\\Theta(1)$. Furthermore, we observe that the clique-width of the complementary prism of a graph of clique-width $k$ is at most $4k$, and discuss some algorithmic consequences.

  16. A Study of the PDGF Signaling Pathway with PRISM

    Qixia Yuan; Jun Pang; Sjouke Mauw; Panuwat Trairatphisan; Monique Wiesinger; Thomas Sauter

    2011-01-01

    In this paper, we apply the probabilistic model checker PRISM to the analysis of a biological system -- the Platelet-Derived Growth Factor (PDGF) signaling pathway, demonstrating in detail how this pathway can be analyzed in PRISM. We show that quantitative verification can yield a better understanding of the PDGF signaling pathway.

  17. New Light on a Prism: The Concert for All Reasons

    Linaberry, Robin

    2004-01-01

    The prism concert concept was introduced in this country at the Eastman School of Music in 1975. The development of Eastman's inaugural prism concert is commonly attributed to Donald Hunsberger and Gustav Meier, conductors of the wind ensemble and orchestra, respectively. The basic idea is that different styles of music performed by different…

  18. Efficacy of enteroclysis through Miller-Abbott tube for decompression in patients with postoperative intestinal obstruction

    The purpose of this study is to assess the efficacy of enteroclysis through the previously inserted Miller-Abbott (M-A) tube for decompression in the postoperative intestinal obstruction. This study includes twenty patients who has intestinal obstruction symptoms after operation for benign(12) or malignant(8) abdominal lesions. Small amount of barium was introduced to M-A tube for enteroclysis. We evaluated the presence, level, degree, and causes of obstruction on enteroclysis, compared with surgical(11) and clinical(9) findings. Obstruction was seen in 18 cases including the two cases in which the level of obstruction was not clear. There was no obstruction in two cases. Obstruction on enteroclysis was demonstrated in all 11 operated cases(100% accuracy, 11/11). The level of obstruction on enteroclysis were jejunum in three cases, ileum in seven, and colon in one case. The levels of obstruction on enteroclysis were matched with those in operation field in 10 cases. There were two cases of nonobstruction on enteroclysis were jejunum in three cases, ileum in seven, and colon in one case. The levels of obstruction on enteroclysis were matched with those in operation field in 10 cases. There were two cases of nonobstruction, nine cases of low-grade partial obstruction, and nine cases of high-grade partial obstruction. We analyzed the findings on enteroclysis regarding causes of obstruction in 16 patients with the findings of adhesive bands of extrinsic cause(9), cancer recurrence of intrinsic cause(6), and bezoar of intraluminal cause(1). Misinterpreted cases were two cases(87.7% accuracy, 14/16). The cause, for nonvisualization of obstruction site on enteroclysis in four patients included technical failure such as inadequate location of tube(1) and bowel overlapping(1), minimal obstruction(1), and nonexistent obstruction(1), in spite of diffuse edematous mucosa. Enteroclysis through the M-A tube for decompression in patients with postoperative intestinal obstruction

  19. Active stereo vision routines using PRISM-3

    Antonisse, Hendrick J.

    1992-11-01

    This paper describes work in progress on a set of visual routines and supporting capabilities implemented on the PRISM-3 real-time vision system. The routines are used in an outdoor robot retrieval task. The task requires the robot to locate a donor agent -- a Hero2000 -- which holds the object to be retrieved, to navigate to the donor, to accept the object from the donor, and return to its original location. The routines described here will form an integral part of the navigation and wide-area search tasks. Active perception is exploited to locate the donor using real-time stereo ranging directed by a pan/tilt/verge mechanism. A framework for orchestrating visual search has been implemented and is briefly described.

  20. Spatial compression impairs prism-adaptation in healthy individuals

    Roger Newport

    2013-05-01

    Full Text Available Neglect patients typically present with gross inattention to one side of space following damage to the contralateral hemisphere. While prism-adaptation is effective in ameliorating some neglect behaviours, the mechanisms involved and their relationship to neglect remain unclear. Recent studies have shown that conscious strategic control processes in prism-adaptation may be impaired in neglect patients, who are also reported to show extraordinarily long aftereffects compared to healthy participants. Determining the underlying cause of these effects may be the key to understanding therapeutic benefits. Alternative accounts suggest that reduced strategic control might result from a failure to detect prism-induced reaching errors properly either because a the size of the error is underestimated in compressed visual space or b pathologically increased error detection thresholds reduce the requirement for error correction. The purpose of this study was to model these two alternatives in healthy participants and to examine whether strategic control and subsequent aftereffects were abnormal compared to standard prism adaptation. Each participant completed three prism-adaptation procedures within a MIRAGE mediated reality environment with direction errors recorded before, during and after adaptation. During prism-adaptation, visual-feedback of the reach could be compressed, perturbed by noise or represented veridically. Compressed visual space significantly reduced strategic control and aftereffects compared to control and noise conditions. These results support recent observations in neglect patients, suggesting that a distortion of spatial representation may successfully model neglect and explain neglect performance while adapting to prisms.

  1. Multicenter Evaluation of the New Abbott RealTime Assays for Quantitative Detection of Human Immunodeficiency Virus Type 1 and Hepatitis C Virus RNA▿

    Schutten, M.; Peters, D.; Back, N.K.T.; Beld, M; Beuselinck, K.; Foulongne, V.; Geretti, A.-M.; Pandiani, L.; Tiemann, C; Niesters, H.G.M.

    2007-01-01

    The analytical performances of the new Abbott RealTime hepatitis C virus (HCV) and human immunodeficiency virus type 1 viral load assays were compared at nine laboratories with different competitor assays. These included the Abbott LcX, Bayer Versant bDNA, Roche COBAS Amplicor, and Roche COBAS TaqMan assays. Two different protocols used during the testing period with and without a pre-m1000 RNA isolation spin were compared. The difference proved to be nonsignificant. A uracil-N-glycosylase (U...

  2. Comparison of the Abbott m2000 HIV-1 Real-Time and Roche AMPLICOR Monitor v1.5 HIV-1 assays on plasma specimens from Rakai, Uganda

    Ssebugenyi, I.; Kizza, A; Mpoza, B; Aluma, G.; Boaz, I.; Newell, K.; Laeyendecker, O; Shott, J P; Serwadda, D; Reynolds, S.J.

    2011-01-01

    The need for viral load (VL) monitoring of HIV patients receiving antiretroviral therapy (ART) in resource-limited settings (RLS) has become apparent with studies showing the limitations of immunological monitoring. We compared the Abbott m2000 Real-Time (Abbott) HIV-1 assay with the Roche AMPLICOR Monitor v1.5 (Roche) HIV-1 assay over a range of VL concentrations. Three hundred and eleven plasma samples were tested, including 164 samples from patients on ART ≥ six months and 147 from ART-naï...

  3. Abbott Aeroset全自动生化分析仪安装调试故障浅析

    苏娜; 胡远明

    2002-01-01

    @@ 我科于2001年11月28日安装了一台Abbott Aeroset全自动生化分析仪,在安装和调试期间出现的几例典型故障及其排除方法介绍如下,以供同行在使用该型号或同等档次的全自动生化分析仪时参考. Abbott Aeroset出厂时虽以整机装箱,在实验室安装时,安装部件只有近水管、4根废液管和2根加样针、4根试剂针加上搅拌器和比色杯以及工作站SCC,容易被工程师忽略整机中的其他部件,这就会导致一些很难觉察的故障.

  4. Recognizing Variable Environments The Theory of Cognitive Prism

    Dong, Tiansi

    2012-01-01

    Normal adults do not have any difficulty in recognizing their homes. But can artificial systems do in the same way as humans? This book collects interdisciplinary evidences and presents an answer from the perspective of computing, namely, the theory of cognitive prism. To recognize an environment, an intelligent system only needs to classify objects, structures them based on the connection relation (not through measuring!), subjectively orders the objects, and compares with the target environment, whose knowledge is similarly structured. The intelligent system works, therefore, like a prism: when a beam of light (a scene) reaches (is perceived) to an optical prism (by an intelligent system), some light (objects) is reflected (are neglected), those passed through (the recognized objects) are distorted (are ordered differently). So comes the term 'cognitive prism'! Two fundamental propositions used in the theory can be informally stated as follow: an orientation relation is a kind of distance comparison relatio...

  5. Mining the Digital Hamburg/ESO Objective Prism Survey

    Christlieb, N.; Wisotzki, L.; Reimers, D.

    2000-01-01

    We report on the exploitation of the stellar content of the Hamburg/ESO objective prism survey by quantitative selection methods, such as automatic spectral classification, and first results obtained.

  6. Dynamics of a microliquid prism actuated by electrowetting.

    Lee, Duck-Gyu; Park, Jaebum; Bae, Jungmok; Kim, Ho-Young

    2013-01-21

    A microliquid prism is a microchannel filled with two immiscible liquids, whose interface acts as a refractive surface. To steer a light beam that constructs optical images, the interface profile or the contact angle is modulated through electrowetting on a dielectric. Accurate, yet agile actuation of the liquid prism critically depends on the understanding of dynamics of the fluid interface. Here we fabricate liquid prisms, visualize the shape evolution of the interface, and theoretically model its dynamics. By comparing the magnitude of capillary forces to those of viscous, inertial and hydrostatic forces, we find that the meniscus motion within submillimetric channels is dominated by the capillary effect. The theoretical predictions for microscale meniscus dynamics are shown to agree well with the experimental measurements. We then discuss the formation of waves in millimetric liquid prisms, which may significantly limit fast and reliable operation of the optofluidic device. PMID:23165931

  7. Strongly-Refractive One-Dimensional Photonic Crystal Prisms

    Ting, David Z. (Inventor)

    2004-01-01

    One-dimensional (1D) photonic crystal prisms can separate a beam of polychromatic electromagnetic waves into constituent wavelength components and can utilize unconventional refraction properties for wavelength dispersion over significant portions of an entire photonic band rather than just near the band edges outside the photonic band gaps. Using a ID photonic crystal simplifies the design and fabrication process and allows the use of larger feature sizes. The prism geometry broadens the useful wavelength range, enables better optical transmission, and exhibits angular dependence on wavelength with reduced non-linearity. The properties of the 1 D photonic crystal prism can be tuned by varying design parameters such as incidence angle, exit surface angle, and layer widths. The ID photonic crystal prism can be fabricated in a planar process, and can be used as optical integrated circuit elements.

  8. Tricapped trigonal prism in crystal chemistry of oxygen lanthanide compounds

    It is shown that in the course of fragmentation of extreme coordination (CP)-icosahedron- 1 9-atom fragment (broken piece) appears to be one of the stages. Minimal transformations turn this 9-atom fragment into a tricapped trigonal prism. The latter represents the only extreme CP, which is built by monodentate acidoanions for the elements of the whole rare earth series. Statistic analysis of Ln-O interatomic distances in tricapped trigonal prisms is performed

  9. Spatial compression impairs prism-adaptation in healthy individuals

    Roger Newport

    2013-01-01

    Neglect patients typically present with gross inattention to one side of space following damage to the contralateral hemisphere. While prism-adaptation is effective in ameliorating some neglect behaviours, the mechanisms involved and their relationship to neglect remain unclear. Recent studies have shown that conscious strategic control processes in prism-adaptation may be impaired in neglect patients, who are also reported to show extraordinarily long aftereffects compared to healthy partici...

  10. Random Prism: a noise-tolerant alternative to Random Forests

    Stahl, Frederic; Bramer, Max

    2014-01-01

    Ensemble learning can be used to increase the overall classification accuracy of a classifier by generating multiple base classifiers and combining their classification results. A frequently used family of base classifiers for ensemble learning are decision trees. However, alternative approaches can potentially be used, such as the Prism family of algorithms that also induces classification rules. Compared with decision trees, Prism algorithms generate modular classification rules that cannot...

  11. Wedge Prism for Direction Resolved Speckle Correlation Interferometry

    The role of a wedge prism for strain sign determination and enhancing the sensitivity for sub-fringe changes is emphasized. The design and incorporation aspects for in-plane sensitive interferometers have been described in detail. Some experimental results dealing with stress determination by laser annealing and speckle correlation interferometry are presented. The prism can also be applied to produce standardized carrier fringes in spatial phase shifting interferometry

  12. Actinide recycle utilizing oxide and metallic fuel in prism

    PRISM is a modular, pool-type sodium-cooled fast reactor employing innovative, passive features to provide an extremely high level of public safety. The PRISM reactor design can accommodate both oxide and metallic fuel forms. A comparison of core design and performance of these forms is made for various options. These options include low fuel cycle cost options, maximum transuranic burning options, and the addition of rare earth elements to the fuel mix. (authors)

  13. Performance of the fully automated progesterone assays on the Abbott AxSYM and the Technicon Immuno 1 Analyser compared with the radioimmunoassay progesterone MAIA

    Test performance of two automated progesterone assays available on the immunoassay analysers Abbott AxSYM and Technicon Immuno 1, respectively, was evaluated in comparison with the radioimmunoassay Progesterone MAIA. For assessment of test performance imprecision, functional sensitivity and linearity of dilution was examined. Correlation with the manual radioimmunoassay was assessed using 122 serum samples over the range 0-110 nmol/L. Imprecision studies revealed for the AxSYM Progesterone within-run CV's of 1.8-6.4% and day-to-day CV's of 3.5-9.7% (concentration range 2.3-75 nmol/L); Immuno 1 Progesterone: within-run CV's 1.0-7.3%, day-to-day CV's 2.3-7.7% (concentration range 1.2-60 nmol/L). The functional sensitivity was <1.7 nmol/L for the AxSYM Progesterone and <1.1 nmol/L for the Immuno 1 Progesterone. With the AxSYM Progesterone the mean recovery after dilution from five samples was 102% (89-107%), from one sample only 69-80% was recovered; with the Immuno 1 Progesterone the mean recovery was 95% (80-105%). Despite of a quite good overall correlation (coefficients 0.972 and 0.981) the relationship of both assays to the Progesterone MAIA significantly deviate from linearity with a considerably higher slope within the lower concentration range. The relationship between the automated assays was linear over the entire concentration range (Immuno = 1.207 * AxSYM + 1; r = 0.986). The time to first result was 20 min for the AxSYM Progesterone, 45 min for the Immuno 1 Progesterone and 90 min for the Progesterone MAIA. The evaluated progesterone assays both exhibit an excellent precision and a high degree of sensitivity. They offer a rapid and flexible method for progesterone determination which may be especially useful for the monitoring of ovarian stimulation during in-vitro fertilization. (author)

  14. Negative Refraction experiments in Photonic Crystal prisms

    Vodo, Plarenta; Parimi, Patanjali. V.; Lu, Wentao. T.; di Gennaro, Emiliano; Sridhar, Srinivas

    2004-03-01

    We have experimentally demonstrated negative refraction in metallic photonic crystal (PC) prisms [1]. The refracted fields in the parallel plate waveguide (PPW) are measured by an automated dipole antenna, which scans the desired area, while the free space (FS) measurements, performed in a anechoic chamber, are measured by a rectangular X-band horn that swings in an arc in far field area. Both TE and TM excitation modes are used in FS experiments. Numerical calculations of the band structure and equi-frequency surface simulations are used to determine frequency regions of negative refraction of the triangular lattice PC. Angle of refraction determined by theoretical simulations and experimental results, are in exceptional good agreement, yielding the negative refraction index. FS and PPW refraction experimental results agree remarkably with simulations. 1. "Negative Refraction and Left-handed electromagnetism in Microwave Photonic Crystals", P.V Parimi, W.T Lu, P.Vodo J. Sokoloff and S.Sridhar, cond-mat/0306109 (2003)

  15. k-Odd mean labeling of prism

    B. Gayathri

    2015-03-01

    Full Text Available ‎A $(p‎,‎q$ graph $G$ is said to have a $k$-odd mean‎ ‎labeling $(k ge 1$ if there exists an injection $f‎ : ‎V‎ ‎to {0‎, ‎1‎, ‎2‎, ‎ldots‎, ‎2k‎ + ‎2q‎ - ‎3}$ such that the‎ ‎induced map $f^*$ defined on $E$ by $f^*(uv =‎ ‎leftlceil frac{f(u+f(v}{2}rightrceil$ is a‎ ‎bijection from $E$ to ${2k - ‎‎‎1‎, ‎2k‎ + ‎1‎, ‎2k‎ + ‎3‎, ‎ldots‎, ‎2‎ ‎k‎ + ‎2q‎ - ‎3}$‎. ‎A graph that admits $k$-odd mean‎ ‎labeling is called $k$-odd mean graph‎. ‎In this paper‎, ‎we investigate $k$-odd mean labeling of prism $C_m times‎ ‎P_n$‎.

  16. PRISM: a planned risk information seeking model.

    Kahlor, LeeAnn

    2010-06-01

    Recent attention on health-related information seeking has focused primarily on information seeking within specific health and health risk contexts. This study attempts to shift some of that focus to individual-level variables that may impact health risk information seeking across contexts. To locate these variables, the researcher posits an integrated model, the Planned Risk Information Seeking Model (PRISM). The model, which treats risk information seeking as a deliberate (planned) behavior, maps variables found in the Theory of Planned Behavior (TPB; Ajzen, 1991) and the Risk Information Seeking and Processing Model (RISP; Griffin, Dunwoody, & Neuwirth, 1999), and posits linkages among those variables. This effort is further informed by Kahlor's (2007) Augmented RISP, the Theory of Motivated Information Management (Afifi & Weiner, 2004), the Comprehensive Model of Information Seeking (Johnson & Meischke, 1993), the Health Information Acquisition Model (Freimuth, Stein, & Kean, 1989), and the Extended Parallel Processing Model (Witte, 1998). The resulting integrated model accounted for 59% of the variance in health risk information-seeking intent and performed better than the TPB or the RISP alone. PMID:20512716

  17. Advanced prism-grating-prism imaging spectrograph in online industrial applications

    Vaarala, Tapio; Aikio, Mauri; Keraenen, Heimo

    1997-08-01

    Imaging spectrographs have traditionally been utilized in aerial and remote sensing applications. A novel, compact and inexpensive imaging spectrograph developed by VTT Electronics is now available. It contains a multichannel fiber optic sensor head, a dispersive prism-grating-prism (PGP) component and digital CCD matrix camera capable of area integration. In rolled steel manufacturing, a protective oil film is applied on steel to resist corrosion while in transport and storage. The main problems in the oiling machine are film thickness control and jet failures. In this application, the spectrum of fluorescence of an oil film was measured simultaneously with parallel fibers. A relatively simple calibration and analysis procedure was used to calculate the oil film thickness. On-line color control for color reproduction is essential in both consumer and industrial products. The instrument was tested and analyzed for measuring differences in color by multivariate analysis of the spectra and by color space coordinate estimation. In general, a continuous spectrum is not absolute requirement. In these two examples, filter-based measurement would probably cost less thana PGP spectrograph solution. On the other hand, by measuring the spectrum and using an advanced signal processing algorithm one production version will cover all installations in both applications. In practice, only the fiber sensor mechanics need to be modified.

  18. Comparison of Perceptions of "Preparedness" of John Abbott C.E.G.E.P. Nursing Graduates: Prior to Graduation and After.

    Iton, Carmen; Sabiston, Judy

    A study of John Abbott College's nursing graduates was conducted to determine how well prepared for their professional responsibilities the graduates saw themselves just prior to graduation and later after working in the nursing field. A sample of 98 nursing students who graduated between 1986 and 1988 was surveyed, with 93% responding to the…

  19. Study of dose calculation on breast brachytherapy using prism TPS

    Fendriani, Yoza; Haryanto, Freddy

    2015-09-01

    PRISM is one of non-commercial Treatment Planning System (TPS) and is developed at the University of Washington. In Indonesia, many cancer hospitals use expensive commercial TPS. This study aims to investigate Prism TPS which been applied to the dose distribution of brachytherapy by taking into account the effect of source position and inhomogeneities. The results will be applicable for clinical Treatment Planning System. Dose calculation has been implemented for water phantom and CT scan images of breast cancer using point source and line source. This study used point source and line source and divided into two cases. On the first case, Ir-192 seed source is located at the center of treatment volume. On the second case, the source position is gradually changed. The dose calculation of every case performed on a homogeneous and inhomogeneous phantom with dimension 20 × 20 × 20 cm3. The inhomogeneous phantom has inhomogeneities volume 2 × 2 × 2 cm3. The results of dose calculations using PRISM TPS were compared to literature data. From the calculation of PRISM TPS, dose rates show good agreement with Plato TPS and other study as published by Ramdhani. No deviations greater than ±4% for all case. Dose calculation in inhomogeneous and homogenous cases show similar result. This results indicate that Prism TPS is good in dose calculation of brachytherapy but not sensitive for inhomogeneities. Thus, the dose calculation parameters developed in this study were found to be applicable for clinical treatment planning of brachytherapy.

  20. Prism-based single-camera system for stereo display

    Zhao, Yue; Cui, Xiaoyu; Wang, Zhiguo; Chen, Hongsheng; Fan, Heyu; Wu, Teresa

    2016-06-01

    This paper combines the prism and single camera and puts forward a method of stereo imaging with low cost. First of all, according to the principle of geometrical optics, we can deduce the relationship between the prism single-camera system and dual-camera system, and according to the principle of binocular vision we can deduce the relationship between binoculars and dual camera. Thus we can establish the relationship between the prism single-camera system and binoculars and get the positional relation of prism, camera, and object with the best effect of stereo display. Finally, using the active shutter stereo glasses of NVIDIA Company, we can realize the three-dimensional (3-D) display of the object. The experimental results show that the proposed approach can make use of the prism single-camera system to simulate the various observation manners of eyes. The stereo imaging system, which is designed by the method proposed by this paper, can restore the 3-D shape of the object being photographed factually.

  1. Study of dose calculation on breast brachytherapy using prism TPS

    PRISM is one of non-commercial Treatment Planning System (TPS) and is developed at the University of Washington. In Indonesia, many cancer hospitals use expensive commercial TPS. This study aims to investigate Prism TPS which been applied to the dose distribution of brachytherapy by taking into account the effect of source position and inhomogeneities. The results will be applicable for clinical Treatment Planning System. Dose calculation has been implemented for water phantom and CT scan images of breast cancer using point source and line source. This study used point source and line source and divided into two cases. On the first case, Ir-192 seed source is located at the center of treatment volume. On the second case, the source position is gradually changed. The dose calculation of every case performed on a homogeneous and inhomogeneous phantom with dimension 20 × 20 × 20 cm3. The inhomogeneous phantom has inhomogeneities volume 2 × 2 × 2 cm3. The results of dose calculations using PRISM TPS were compared to literature data. From the calculation of PRISM TPS, dose rates show good agreement with Plato TPS and other study as published by Ramdhani. No deviations greater than ±4% for all case. Dose calculation in inhomogeneous and homogenous cases show similar result. This results indicate that Prism TPS is good in dose calculation of brachytherapy but not sensitive for inhomogeneities. Thus, the dose calculation parameters developed in this study were found to be applicable for clinical treatment planning of brachytherapy

  2. Reverse time migration of prism waves for salt flank delineation

    Dai, Wei

    2013-09-22

    In this paper, we present a new reverse time migration method for imaging salt flanks with prism wave reflections. It consists of four steps: (1) migrating the seismic data with conventional RTM to give the RTM image; (2) using the RTM image as a reflectivity model to simulate source-side reflections with the Born approximation; (3) zero-lag correlation of the source-side reflection wavefields and receiver-side wavefields to produce the prism wave migration image; and (4) repeating steps 2 and 3 for the receiver-side reflections. An advantage of this method is that there is no need to pick the horizontal reflectors prior to migration of the prism waves. It also separately images the vertical structures at a different step to reduce crosstalk interference. The disadvantage of prism wave migration algorithm is that its computational cost is twice that of conventional RTM. The empirical results with a salt model suggest that prism wave migration can be an effective method for salt flank delineation in the absence of diving waves.

  3. Fun Fitness Runs.

    Scantling, Ed; Strand, Brad

    1997-01-01

    Fitness runs are planned activities that make running more interesting. The paper outlines five types of fitness runs, all of which can be modified to conform to different facilities, age groups, or available time. The activities have students playing detective, playing cards, deciphering words, learning about calories, and playing wolf. (SM)

  4. Birefringent neutron prisms for spin echo scattering angle measurement

    Pynn, Roger, E-mail: rpynn@indiana.ed [Indiana University, Bloomington, IN (United States); Oak Ridge National Laboratory, Oak Ridge, TN (United States); Fitzsimmons, M.R. [Los Alamos National Laboratory, Los Alamos, NM (United States); Lee, W.T. [Oak Ridge National Laboratory, Oak Ridge, TN (United States); Stonaha, P.; Shah, V.R.; Washington, A.L. [Indiana University, Bloomington, IN (United States); Kirby, B.J.; Majkrzak, C.F.; Maranville, B.B. [National Institute of Standards and Technology (United States)

    2009-09-01

    In the first decade of the 19th century, an English chemist, William Wollaston, invented an arrangement of birefringent prisms that splits a beam of light into two spatially separated beams with orthogonal polarizations. We have constructed similar devices for neutrons using triangular cross-section solenoids and employed them for Spin Echo Scattering Angle Measurement (SESAME). A key difference between birefringent neutron prisms and their optical analogues is that it is hard to embed the former in a medium which has absolutely no birefringence because this implies the removal of all magnetic fields. We have overcome this problem by using the symmetry properties of the Wollaston neutron prisms and of the overall spin echo arrangement. These symmetries cause a cancellation of Larmor phase aberrations and provide robust coding of neutron scattering angles with simple equipment.

  5. Nuclear medicine gamma camera system PRISM-XP series

    Recently, SPECT gamma camera systems have become important in RI imaging of the brain and torso. The PRISM-XP series is a new SPECT system which employs multiple detectors, a fan beam collimator and a non-circular orbit for improved acquisition speed and sensitivity. For improved data processing, this machine uses a 64-bit CPU and a 3D graphics subsystem specially designed for image processing. The PRISM-XP series also includes 3-detector, 2-detector and 1-detector systems. The dual and single detector systems also have functions for whole-body imaging. In this article, the PRISM-XP series, which is commercialized by PICKER International Inc, Ohio, U.S.A., is presented. (author)

  6. Advanced hyperspectral video imaging system using Amici prism.

    Feng, Jiao; Fang, Xiaojing; Cao, Xun; Ma, Chenguang; Dai, Qionghai; Zhu, Hongbo; Wang, Yongjin

    2014-08-11

    In this paper, we propose an advanced hyperspectral video imaging system (AHVIS), which consists of an objective lens, an occlusion mask, a relay lens, an Amici prism and two cameras. An RGB camera is used for spatial reading and a gray scale camera is used for measuring the scene with spectral information. The objective lens collects more light energy from the observed scene and images the scene on an occlusion mask, which subsamples the image of the observed scene. Then, the subsampled image is sent to the gray scale camera through the relay lens and the Amici prism. The Amici prism that is used to realize spectral dispersion along the optical path reduces optical distortions and offers direct view of the scene. The main advantages of the proposed system are improved light throughput and less optical distortion. Furthermore, the presented configuration is more compact, robust and practicable. PMID:25321019

  7. Quartz-Enhanced Photoacoustic Spectroscopy with Right-Angle Prism

    Yongning Liu; Jun Chang; Jie Lian; Zhaojun Liu; Qiang Wang; Zengguang Qin

    2016-01-01

    A right-angle prism was used to enhance the acoustic signal of a quartz-enhanced photoacoustic spectroscopy (QEPAS) system. The incident laser beam was parallelly inverted by the right-angle prism and passed through the gap between two tuning fork prongs again to produce another acoustic excitation. Correspondingly, two pairs of rigid metal tubes were used as acoustic resonators with resonance enhancement factors of 16 and 12, respectively. The QEPAS signal was enhanced by a factor of 22.4 co...

  8. Transmission and Distribution of Optical Field in Prism Coupler

    Transmission and distribution characteristics of optical field in prism coupler are studies, and the phase matching function of prism coupler is deduced based on coupled wave theory. It is shown that the stable light field distribution and mode pattern are determined by its own geometric and dielectric parameters, but have nothing to do with the categories of incident light sources. It is also found that the coupling effect would generate between waveguides through evanescent field. Our numerical simulation is based on the finite difference time domain method with perfectly matched layer absorbing boundary condition. The simulation program is compiled in MATLAB. The simulation results are analyzed carefully.

  9. Temperature Influence on Divergence Angles of Quartz Crystal Wollaston Prism

    We propose a structural angle and main refractive indices as two key factors to understand the temperature influence on the divergence angles of the Wollaston prism. The temperature influence on the divergence angles of quartz crystal Wollaston prism is studied theoretically The results show that divergence angles decrease with increasing temperature, while the divergence angle of e-light decrease more quickly than that of o-light. The testing system is established to verify the above results, and the experimental results are in agreement well with the theoretical analysis. (fundamental areas of phenomenology (including applications))

  10. Assessment of PRISM responses to loss of flow events

    The Nuclear Regulatory Commission (NRC), with Brookhaven National Laboratory providing technical support, is continuing a preapplication review of the 471 MWt, Advanced Liquid Metal Reactor (ALMR), PRISM by General Electric. The revised design has been evaluated using the SSC code, for a series of loss of flow events (LOF) with and without Gas Expansion Modules (GEMs). These devices have a net worth of 69 cents and have reduced the seriousness of the LOF in PRISM. However, it was found that the extremely low probability case of an instantaneous loss of 4 EM pumps without scram could lead to sodium boiling even with the GEMs. (author)

  11. Prism refractive index measurement at INRiM

    A simple method to measure the refractive index of a glass prism with very low uncertainty was developed at INRiM. The method is a modification of the classical minimum deviation method. A brief description of the methods used to measure the vertex angles of the prism and the angle of minimum deviation is reported together with the uncertainty evaluation. The technique is going to be validated by a comparison between INRiM and two other laboratories. A relative standard uncertainty better than 1 ppm has been obtained

  12. Intricacies of Feedback in Computer-based Prism Adaptation Therapy

    Wilms, Inge Linda; Rytter, Hana Malá

    Prism Adaptation Therapy (PAT) is an intervention method for treatment of attentional disorders, such as neglect e.g. 1,2. The method involves repeated pointing at specified targets with or without prism glasses using a specifically designed wooden box. The aim of this study was to ascertain...... direct feedback (physical finger) on pointing precision. Attempts to provide feedback indirectly via icons on the computer screen fail to create the aftereffects observed in the original PAT. The findings have direct implications for future implementations of computer-based methods in treatment of...

  13. Cerebellar inactivation impairs memory of learned prism gaze-reach calibrations

    Norris, Scott A.; Hathaway, Emily N.; Taylor, Jordan A.; Thach, W. Thomas

    2011-01-01

    Three monkeys performed a visually guided reach-touch task with and without laterally displacing prisms. The prisms offset the normally aligned gaze/reach and subsequent touch. Naive monkeys showed adaptation, such that on repeated prism trials the gaze-reach angle widened and touches hit nearer the target. On the first subsequent no-prism trial the monkeys exhibited an aftereffect, such that the widened gaze-reach angle persisted and touches missed the target in the direction opposite that o...

  14. A high throughput (>90%), large compensation range, single-prism femtosecond pulse compressor

    Kong, Lingjie; Cui, Meng

    2013-01-01

    We demonstrate a high throughput, large compensation range, single-prism femtosecond pulse compressor, using a single prism and two roof mirrors. The compressor has zero angular dispersion, zero spatial dispersion, zero pulse-front tilt, and unity magnification. The high efficiency is achieved by adopting two roof mirrors as the retroreflectors. We experimentally achieved ~ -14500 fs2 group delay dispersion (GDD) with 30 cm of prism tip-roof mirror prism separation, and ~90.7% system throughp...

  15. Education through the prism of computation

    Kaurov, Vitaliy

    2014-03-01

    With the rapid development of technology, computation claims its irrevocable place among research components of modern science. Thus to foster a successful future scientist, engineer or educator we need to add computation to the foundations of scientific education. We will discuss what type of paradigm shifts it brings to these foundations on the example of Wolfram Science Summer School. It is one of the most advanced computational outreach programs run by Wolfram Foundation, welcoming participants of almost all ages and backgrounds. Centered on complexity science and physics, it also covers numerous adjacent and interdisciplinary fields such as finance, biology, medicine and even music. We will talk about educational and research experiences in this program during the 12 years of its existence. We will review statistics and outputs the program has produced. Among these are interactive electronic publications at the Wolfram Demonstrations Project and contributions to the computational knowledge engine Wolfram|Alpa.

  16. The demagnetizing field of a non-uniform rectangular prism

    Smith, Anders; Nielsen, Kaspar Kirstein; Christensen, Dennis;

    2010-01-01

    The effect of demagnetization on the magnetic properties of a rectangular ferromagnetic prism under non-uniform conditions is investigated. A numerical model for solving the spatially varying internal magnetic field is developed, validated and applied to relevant cases. The demagnetizing field is......-uniformity of the internal field, especially for non-constant temperature distributions and composite magnetic materials....

  17. A decomposition theorem for binary matroids with no prism minor

    Kingan, Sandra

    2012-01-01

    The prism graph is the dual of the complete graph on five vertices with an edge deleted, $K_5\\backslash e$. In this paper we determine the class of binary matroids with no prism minor. The motivation for this problem is the 1963 result by Dirac where he identified the simple 3-connected graphs with no minor isomorphic to the prism graph. We prove that besides Dirac's infinite families of graphs and four infinite families of non-regular matroids determined by Oxley, there are only three possibilities for a matroid in this class: it is isomorphic to the dual of the generalized parallel connection of $F_7$ with itself across a triangle with an element of the triangle deleted; it's rank is bounded by 5; or it admits a non-minimal exact 3-separation induced by the 3-separation in $P_9$. Since the prism graph has rank 5, the class has to contain the binary projective geometries of rank 3 and 4, $F_7$ and $PG(3, 2)$, respectively. We show that there is just one rank 5 extremal matroid in the class. It has 17 element...

  18. Astigmatism and coma-free prism dye ring laser

    The characteristics of two prism ring lasers for cw operation have been experimentally studied. With improved compensation for aberrations due to astigmatism and coma, cw ring lasers operated in the traveling-wave mode provide high output efficiency, stable narrow bandwidth in multimode and single-mode operation, and a broad tuning range

  19. Cardiac rate detection method based on the beam splitter prism

    Yang, Lei; Liu, Xiaohua; Liu, Ming; Zhao, Yuejin; Dong, Liquan; Zhao, Ruirui; Jin, Xiaoli; Zhao, Jingsheng

    2013-09-01

    A new cardiac rate measurement method is proposed. Through the beam splitter prism, the common-path optical system of transmitting and receiving signals is achieved. By the focusing effect of the lens, the small amplitude motion artifact is inhibited and the signal-to-noise is improved. The cardiac rate is obtained based on the PhotoPlethysmoGraphy (PPG). We use LED as the light source and use photoelectric diode as the receiving tube. The LED and the photoelectric diode are on the different sides of the beam splitter prism and they form the optical system. The signal processing and display unit is composed by the signal processing circuit, data acquisition device and computer. The light emitted by the modulated LED is collimated by the lens and irradiates the measurement target through the beam splitter prism. The light reflected by the target is focused on the receiving tube through the beam splitter prism and another lens. The signal received by the photoelectric diode is processed by the analog circuit and obtained by the data acquisition device. Through the filtering and Fast Fourier Transform, the cardiac rate is achieved. We get the real time cardiac rate by the moving average method. We experiment with 30 volunteers, containing different genders and different ages. We compare the signals captured by this method to a conventional PPG signal captured concurrently from a finger. The results of the experiments are all relatively agreeable and the biggest deviation value is about 2bmp.

  20. The Pacific Oaks College's Prism Principles Professional Development Approach

    Beyer, Kalani

    2012-01-01

    In a struggling atmosphere for education, one college is optimistic about the future by offering school districts its PRISM Principles professional development as a means to ensure that "no child is left behind." Pacific Oaks College & Children's School is known for its premiere programs in early childhood education, human…

  1. Portable Remote Imaging Spectrometer (PRISM): Laboratory and Field Calibration

    Mouroulis, Pantazis; Van Gorp, Byron; Green, Robert O.; Eastwood, Michael; Boardman, Joseph; Richardson, Brandon S.; Rodriguez, Jose I.; Urquiza, Eugenio; Franklin, Brian D.; Gao, Bo-Cai

    2012-01-01

    We report the characteristics of the Portable Remote Imaging Spectrometer, an airborne sensor specifically designed for the challenges of coastal ocean research. PRISM has high signal to noise ratio and uniformity, as well as low polarization sensitivity. Acquisition of high quality data has been demonstrated with the first engineering flight.

  2. Programmable agile beam steering based on a liquid crystal prism

    To meet the application need for agile precision beam steering, a novel liquid crystal prism device with a simple structure, convenient control, low cost and applicable performance is presented, and analysed theoretically and experimentally. The relationships between the optical path and the thickness of the liquid crystal cell under different voltages are investigated quantitatively by using a theoretical model. Analysis results show that the optical path profile of the liquid crystal prism has a quasi-linear slope and the standard deviation of the linear slope is less than 16 nm. The slope ratio can be changed by a voltage, which achieves the programmable beam steering and control. Practical liquid crystal prism devices are fabricated. Their deflection angles and wavefront profiles with different voltages are experimentally tested. The results are in good agreement with the simulated results. The results imply that the agile beam steering in a scope of 100 μrad with a micro-rad resolution is substantiated in the device. The two-dimensional beam steering is also achieved by cascading two liquid crystal prism devices. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  3. First Observation of Neutron Deflections by Single Crystal Prisms

    For a monochromatic neutron beam incident on a single crystal prism, we derived analytic expressions for variations of the deflection δcr and transmitted fraction IO of forward diffracted neutrons, with the incidence angle θ. In the vicinity of a Bragg reflection, δcr deviates sharply from the deflection δam for an equivalent amorphous prism, reaching opposite extrema at either end of the total reflectivity domain and exhibits a 3 orders of magnitude greater sensitivity to θ than δam. We have experimentally observed the variation of δcr and IO across a Bragg reflection for single crystal silicon prisms of various apex angles in several asymmetric Bragg configurations. The observed δcr deviates from δam by upto 27% with sensitivities |dδcr/dθ| upto 0.43 arcsec/arcsec. The results are in harmony with theory. This observation has led to the design of a super-collimator Bragg prism producing neutron beams with sub-arcsecond angular widths.

  4. Electrowetting-Controlled Dual Liquid Prism for Adaptive Beam Steering

    Cheng, Jiangtao

    2015-03-01

    The use of concentrating photovoltaic (CPV) technology has been the most promising method of harvesting solar radiation. These CPV systems often require motor-driven tracking devices to steer the sun's beams onto solar cells. The cost of maintaining these tracking systems is the primary inhibitor for widespread application. We aim to overcome the need for mechanical trackers through the use of an electrowetting-driven solar tracking (EWST) system. The electrowetting-driven solar tracking system consists of an array of novel electrowetting-controlled dual liquid prisms, which are filled with immiscible fluids that have large differences in refractive indices. The naturally formed meniscus between the fluids can function as a dynamic optical prism. Via the full-range modulation of the liquid prisms, incident sunlight can be adaptively tracked, steered, and focused onto CPV cells through a fixed optical condenser. Furthermore, unlike the conventional and cumbersome motor-driven tracking systems used today, the liquid prism system would be suitable for rooftop applications. The results of this project reveal that the EWST system has the potential to generate ~ 70% more green energy at 50% of the conventional capital cost.

  5. Coxeter Decompositions of Bounded Hyperbolic Pyramids and Triangular Prisms

    Felikson, A.

    2002-01-01

    Coxeter decompositions of hyperbolic simplices where studied in math.MG/0212010 and math.MG/0210067. In this paper we use the methods of these works to classify Coxeter decompositions of bounded convex pyramids and triangular prisms in the hyperbolic space H^3.

  6. THz Photonic Band-Gap Prisms Fabricated by Fiber Drawing

    Busch, Stefan F.; Xu, Lipeng; Stecher, Matthias;

    2012-01-01

    We suggest a novel form of polymeric based 3D photonic crystal prisms for THz frequencies which could be fabricated using a standard fiber drawing technique. The structures are modeled and designed using a finite element analyzing technique. Using this simulation software we theoretically study...... their performance....

  7. Prism adaptation contrasts perceptual habituation for repetitive somatosensory stimuli.

    Torta, D M; Tatu, M K; Cotroneo, D; Alamia, A; Folegatti, A; Trojan, J

    2016-03-01

    Prism adaptation (PA) is a non-invasive procedure that requires performing a visuo-motor pointing task while wearing prism goggles inducing a visual displacement of the pointed target. This procedure involves a reorganization of sensorimotor coordination, and induces long-lasting effects on numerous higher-order cognitive functions in healthy volunteers and neglect patients. Prismatic displacement (PD) of the visual field can be induced when prisms are worn but no sensorimotor task is required. In this case, it is unlikely that any subsequent reorganization takes place. The effects of PD are short-lived in the sense that they last as long as prisms are worn. In this study we aimed, to the best of our knowledge for the first time, at investigating whether PA and PD induce changes in the perception of intensity of nociceptive and non- nociceptive somatosensory stimuli. We induced, in healthy volunteers, PD (experiment 1), or PA (experiment 2) and asked participants to rate the intensity of the stimuli applied to the hand undergoing the visuo-proprioceptive conflict (experiment 1) or adaptation (experiment 2). Our results indicate that: 1) the visuo-proprioceptive conflict induced by PD does not reduce the perceived intensity of the stimuli, 2) PA prevents perceptual habituation for both nociceptive and non-nociceptive somatosensory stimuli. Moreover, to investigate the possible underlying mechanisms of the effects of PA we conducted a third experiment in which stimuli were applied both at the adapted and the non-adapted hand. In line with the results of experiment 2, we found that perceptual habituation was prevented for stimuli applied onto the adapted hand. Moreover, we observed the same finding for stimuli applied onto the non-adapted hand. This result suggests that the detention of habituation is not merely driven by changes in spatial attention allocation. Taken together, these data indicate that prisms can affect the perceived intensity of somatosensory stimuli

  8. Study of dose calculation on breast brachytherapy using prism TPS

    Fendriani, Yoza; Haryanto, Freddy [Nuclear Physics and Biophysics Research Division, FMIPA Institut Teknologi Bandung, Physics Buildings, Jl. Ganesha 10, Bandung 40132 (Indonesia)

    2015-09-30

    PRISM is one of non-commercial Treatment Planning System (TPS) and is developed at the University of Washington. In Indonesia, many cancer hospitals use expensive commercial TPS. This study aims to investigate Prism TPS which been applied to the dose distribution of brachytherapy by taking into account the effect of source position and inhomogeneities. The results will be applicable for clinical Treatment Planning System. Dose calculation has been implemented for water phantom and CT scan images of breast cancer using point source and line source. This study used point source and line source and divided into two cases. On the first case, Ir-192 seed source is located at the center of treatment volume. On the second case, the source position is gradually changed. The dose calculation of every case performed on a homogeneous and inhomogeneous phantom with dimension 20 × 20 × 20 cm{sup 3}. The inhomogeneous phantom has inhomogeneities volume 2 × 2 × 2 cm{sup 3}. The results of dose calculations using PRISM TPS were compared to literature data. From the calculation of PRISM TPS, dose rates show good agreement with Plato TPS and other study as published by Ramdhani. No deviations greater than ±4% for all case. Dose calculation in inhomogeneous and homogenous cases show similar result. This results indicate that Prism TPS is good in dose calculation of brachytherapy but not sensitive for inhomogeneities. Thus, the dose calculation parameters developed in this study were found to be applicable for clinical treatment planning of brachytherapy.

  9. Sediment compaction and fluid migration in the Makran Accretionary Prism

    Minshull, Tim; White, Robert

    1989-06-01

    The Makran continental margin in the Gulf of Oman forms the seaward extremity of an accretionary sediment prism which extends several hundred kilometers inland. A recently acquired multichannel seismic reflection profile shot across the margin imaged the structure of the prism in greater detail than was previously possible and allowed us to investigate the relationship between deformation and pore fluid motion in the region. Velocity analyses of the common midpoint gathers reveal a marked change in velocity structure at the toe of the accretionary wedge, as seen in previous sonobuoy wide-angle data. Accreted sediments show significantly higher vertical velocity gradients than those of sediments entering the prism; this change is interpreted as due to porosity reduction as pore fluids are squeezed out of the compacting sediment. A prominent "bottom simulating reflector" appears 500-800 m beneath the sea bed. Several lines of evidence suggest that this reflector represents the base of a gas hydrate zone underlain by widespread free gas, which may be exsolved from pore water migrating from deep within the sediment pile up permeable fault planes imaged in the profile. The hydrate reflector appears to shallow in the region of some faults, suggesting a temperature anomaly due to the presence of warm pore fluids. A heat flow profile derived from the depth of the hydrate reflector does not show the expected landward decrease as the sediment pile thickens. Simple thermal modeling suggests that advective heat flow within the prism may explain this anomaly. The inferred presence of overpressured pore fluids in the Makran suggests that accreted sediments have a low permeability. The seismic evidence suggests a two-stage compaction process, with rapid initial dewatering through intergranular permeability as sediment enters the prism followed by a buildup of pore pressure as the permeability decreases and fluid migration is restricted to fault zones.

  10. Superconducting magnetic Wollaston prism for neutron spin encoding

    A magnetic Wollaston prism can spatially split a polarized neutron beam into two beams with different neutron spin states, in a manner analogous to an optical Wollaston prism. Such a Wollaston prism can be used to encode the trajectory of neutrons into the Larmor phase associated with their spin degree of freedom. This encoding can be used for neutron phase-contrast radiography and in spin echo scattering angle measurement (SESAME). In this paper, we show that magnetic Wollaston prisms with highly uniform magnetic fields and low Larmor phase aberration can be constructed to preserve neutron polarization using high temperature superconducting (HTS) materials. The Meissner effect of HTS films is used to confine magnetic fields produced electromagnetically by current-carrying HTS tape wound on suitably shaped soft iron pole pieces. The device is cooled to ∼30 K by a closed cycle refrigerator, eliminating the need to replenish liquid cryogens and greatly simplifying operation and maintenance. A HTS film ensures that the magnetic field transition within the prism is sharp, well-defined, and planar due to the Meissner effect. The spin transport efficiency across the device was measured to be ∼98.5% independent of neutron wavelength and energizing current. The position-dependent Larmor phase of neutron spins was measured at the NIST Center for Neutron Research facility and found to agree well with detailed simulations. The phase varies linearly with horizontal position, as required, and the neutron beam shows little depolarization. Consequently, the device has advantages over existing devices with similar functionality and provides the capability for a large neutron beam (20 mm × 30 mm) and an increase in length scales accessible to SESAME to beyond 10 μm. With further improvements of the external coupling guide field in the prototype device, a larger neutron beam could be employed

  11. Abbott RealTime HIV-1 m2000rt viral load testing: Manual extraction versus the automated m2000sp extraction

    Scott, Lesley E.; Crump, John A.; Msuya, Emma; Morrissey, Anne B.; Venter, Willem F.; Stevens, Wendy S.

    2010-01-01

    The Abbott RealTime HIV-1 assay is a real-time nucleic acid amplification assay available for HIV-1 viral load quantitation. The assay has a platform for automated extraction of viral RNA from plasma or dried blood spot samples, and an amplification platform with real time fluorescent detection. Overall, this study found no clinically relevant differences in viral load, if samples were extracted manually.

  12. Efficient Quantification of HIV-1 in Heparin Plasma Spiked with Cultured HIV-1 by the Roche Cobas TaqMan and Abbott RealTime HIV-1 Tests

    Jagodzinski, Linda L; Weston, Holly R.; Liu, Ying; O'Connell, Robert J.; Peel, Sheila A

    2012-01-01

    The current automated real-time HIV-1 viral load assays, the Roche Cobas AmpliPrep/Cobas TaqMan test and the Abbott RealTime test, are FDA cleared for use with EDTA plasma. We show that both real-time reverse transcription-PCR (RT-PCR) tests reliably quantify HIV-1 RNA in heparin plasma specimens spiked with HIV-1 isolate MN.

  13. Sensitivity and specificity of the GAMMACOAT-M CEA-RIA from Travenol-Genentech Diagnostics compared to the ABBOTT CEA-RIA monoclonal

    A new monoclonal radioimmunoassay from Travenol-Genentech Diagnostics was investigated with respect to its sensitivity and specificity and compared to the established monoclonal antibody assay of ABBOTT. Both tests revealed increased CEA plasma values in healthy smokers, whereby the elevation was dependent on the number of cigarettes smoked per day. The sensitivities as well as the cut-off levels for CEA at 90% specificity were coincident in both tests. (orig.)

  14. Study on the conditions for stabilizing trigonal-prism coordination compounds

    A new calculating method has been proposed for the elongation and twist of trigonal-prism. The calculations show that the calculated and determined values of the bite for bidentate trigonal prism complexes are similar and that rigidity of the bite favors the stabilization of the trigonal prism configuration. The structural characteristics of the bidentate ligands and central atoms are further discussed based on the structural data of trigonal-prism compounds. The discussion provides a guide for the preparation of new trigonal-prism labelled compounds

  15. Postural Stability Changes during Large Vertical Diplopia Induced by Prism Wear in Normal Subjects

    Matsuo,Toshihiko; Yamasaki,Hanako; Yasuhara,Hirotaka; Hasebe, Kayoko

    2013-01-01

    To test the effect of double vision on postural stability, we measured postural stability by electric stabilometry before prism-wearing and immediately, 15, 30, and 60min after continuous prism-wearing with 6 prism diopters in total (a 3-prism-diopter prism placed with the base up in front of one eye and with the base down in front of the other eye) in 20 normal adult individuals with their eyes open or closed. Changes in stabilometric parameters in the time course of 60min were analyzed stat...

  16. PREDICTION OF OUTCOME OF PAEDIATRIC PATIENTS BY VALIDATING PRISM III SCORING WITHIN 12 HOURS AND PRISM III AT 72-84 HOURS AFTER INITIATION OF THE TREATMENT

    Sonica

    2014-01-01

    `BACKGROUND: One of the scoring systems in Pediatric Intensive Care is the PRISM III (PAEDITRIC RISK OF MORTALITY III) which is an updated version of PRISM. Study was done at time point 72 hrs of initiation of therapy as well in a view that it will better prognosticate the outcome. AIMS: 1. To find out PRISM III within 1st 12 hours of admission and at 72-84 hours of admission, 2. To evaluate any correlation between PRISM III and mortality, 4.To find out correlation between...

  17. The LHCb Run Control

    Alessio, F; Callot, O; Duval, P-Y; Franek, B; Frank, M; Galli, D; Gaspar, C; v Herwijnen, E; Jacobsson, R; Jost, B; Neufeld, N; Sambade, A; Schwemmer, R; Somogyi, P

    2010-01-01

    LHCb has designed and implemented an integrated Experiment Control System. The Control System uses the same concepts and the same tools to control and monitor all parts of the experiment: the Data Acquisition System, the Timing and the Trigger Systems, the High Level Trigger Farm, the Detector Control System, the Experiment's Infrastructure and the interaction with the CERN Technical Services and the Accelerator. LHCb's Run Control, the main interface used by the experiment's operator, provides access in a hierarchical, coherent and homogeneous manner to all areas of the experiment and to all its sub-detectors. It allows for automated (or manual) configuration and control, including error recovery, of the full experiment in its different running modes. Different instances of the same Run Control interface are used by the various sub-detectors for their stand-alone activities: test runs, calibration runs, etc. The architecture and the tools used to build the control system, the guidelines and components provid...

  18. Transient safety performance of the PRISM innovative liquid metal reactor

    The PRISM sodium-cooled reactor concept utilizes passive safety characteristics and modularity to increase performance margins, improve licensability, reduce owner's risk and reduce costs. The relatively small size of each reactor module (471 MWt) facilitates the use of passive self-shutdown and shutdown heat removal features, which permit design simplification and reduction of safety-related systems. Key to the transient performance is the inherent negative reactivity feedback characteristics of the core design resulting from the use of metal (U-Pu-Zr) swing, and very low control rod runout worth. Selected beyond design basis events relying only on these core design features are analyzed and the design margins summarized to demonstrate the advancement in reactor safety achieved with the PRISM design concept

  19. Hyperbolic prisms and foams in Hele-Shaw cells

    The propagation of light in foams creates patterns which are generated due to the reflection and refraction of light. One of these patterns is observed by the formation of multiple mirror images inside liquid bridges in a layer of bubbles in a Hele-Shaw cell. We are presenting the existence of these patterns in foams and their relation with hyperbolic geometry and Sierpinski gaskets using the Poincare disk model. The images obtained from the experiment in foams are compared to the case of hyperbolic optical elements. -- Highlights: → The chaotic scattering of light in foams generating deltoid patterns is based on hyperbolic geometry. → The deltoid patterns are obtained through the Plateau borders in a Hele-Shaw cell. → The Plateau borders act like hyperbolic prism. → Some effects of the refraction and reflection of the light rays were studied using a hyperbolic prism.

  20. Extremely simple single-prism ultrashort- pulse compressor.

    Akturk, Selcuk; Gu, Xun; Kimmel, Mark; Trebino, Rick

    2006-10-16

    We have designed and demonstrated a very simple and compact ultrashort-pulse compressor using a single prism and a corner-cube. Our design is significantly easier to align and tune compared with previous designs. Angle-tuning the prism wavelength-tunes, and translating the corner cube varies the group-delay dispersion over a wide range. When tuned, the device automatically maintains zero angular dispersion, zero pulse-front tilt, zero spatial chirp, and unity magnification. The device can easily be built so that its output beam remains collinear with the input beam, and when the input beam or pulse compressor moves, the input and output beams remain collinear. PMID:19529405

  1. Enraizamento de estacas caulinares de kiwi (Actinidia chinensis Planch cv Abbott tratadas com auxinas e boro Rooting of kiwi stem cuttings (Actinidia chinensis Planch. cv Abbott treated with auxins and boron

    E.G. Ono

    1995-12-01

    Full Text Available O trabalho teve como finalidade, estudar o efeito de várias auxinas sintéticas em formulações comerciais e do boro, sobre o enraizamento de estacas caulinares de kiwi (Actinidia chinensis Planch, cv Abbott.. As estacas utilizadas continham dois nós e duas folhas cortadas ao meio, com aproximadamente 10 cm de comprimento, onde o corte basal em bisel foi realizado logo abaixo de um nó e o apical acima do outro nó. O efeito das auxinas, sobre o enraizamento de estacas caulinares de kiwi foi verificado mediante os seguintes tratamentos, aplicados sobre as bases das estacas: T1 H(20; T2 (NAA 300 ppm; T3 (IBA 300 ppm; T4 (NAA 300 ppm + B; T5 (IBA 300 ppm + B; T6 (NAA 0,5%-pó e T7 (IBA 0,5%-pó. Após o tratamento das estacas, estas foram plantadas em bandejas de enraizamento, contendo vermiculita pura e colocadas em câmara de nebulização, onde permaneceram por 120 dias, até a sua coleta. Para a avaliação do efeito de auxinas e do ácido bórico, sobre o enraizamento de estacas caulinares de kiwi, foram realizadas as seguintes observações: 1. porcentagem de estacas enraizadas; 2. análise de açúcares redutores e açúcares totais (em g/100 g de matéria seca; 3. análise de triptofano (em µg/100 mg de matéria seca. Os resultados obtidos no processo de enraizamento de estacas caulinares de kiwi (Actinidia chinensis Planch. variedade Abbott, levou a concluir que o inverno e outono foram as melhores épocas de coleta dos ramos de auxinas para a confecção das estacas. O processo de enraizamento foi ainda incrementado com a aplicação exógena na base das estacas, sendo que o alto teor de açúcares redutores e totais beneficiou a maior porcentagem de enraizamento.This study was carried out to evaluate the effects of some synthetical auxins and boron trade formulations in the rooting of stem cuttings of some kiwi (Actinidia chinensis Planch varieties. The experiment was carried out in a misty nebulization chamber in the Botany

  2. Stereovision Imaging in Smart Mobile Phone Using Add on Prisms

    Bar-Magen Numhauser, Jonathan; Zalevsky, Zeev

    2014-03-01

    In this work we present the use of a prism-based add on component installed on top of a smart phone to achieve stereovision capabilities using iPhone mobile operating system. Through these components and the combination of the appropriate application programming interface and mathematical algorithms the obtained results will permit the analysis of possible enhancements for new uses to such system, in a variety of areas including medicine and communications.

  3. Prism-coupled light emission from tunnel junctions

    Ushioda, S.; Rutledge, J. E.; Pierce, R. M.

    1985-01-01

    Completely p-polarized light emission has been observed from smooth Al-AlO(x)-Au tunnel junctions placed on a prism coupler. The angle and polarization dependence demonstrate unambiguously that the emitted light is radiated by the fast-mode surface plasmon polariton. The emission spectra suggest that the dominant process for the excitation of the fast mode is through conversion of the slow mode to the fast mode mediated by residual roughness on the junction surface.

  4. Advanced SFR Concept Based on PRISM and KALIMER

    The Sodium-cooled Fast Reactor has been recognized as one of the promising nuclear options for generating electricity with efficient uranium resource utilization and reduction of radioactive wastes from nuclear power plants. This paper compares design features, identifies differences between KALIMER-600 and S-PRISM sodium-cooled reactors, and derives R and D requirements in order to explore the possibility of developing a novel SFR concept. (author)

  5. Prism adaptation does not alter configural processing of faces

    Bultitude, Janet H.; Downing, Paul E.; Robert D. Rafal

    2013-01-01

    Patients with hemispatial neglect (‘neglect’) following a brain lesion show difficulty responding or orienting to objects and events on the left side of space. Substantial evidence supports the use of a sensorimotor training technique called prism adaptation as a treatment for neglect. Reaching for visual targets viewed through prismatic lenses that induce a rightward shift in the visual image results in a leftward recalibration of reaching movements that is accompanied by a reduction of symp...

  6. Stereo Evaluation Of ALOS PRISM And IKONOS In Yemen

    Müller, Rupert; Schneider, Mathias; Radhadevi, P.V.; Reinartz, Peter; Schwonke, Friedhelm

    2009-01-01

    DLR's Remote Sensing Technology Institute has a long lasting experience in developing spaceborne stereo scanners (MEOSS, MOMS) and the corresponding photogrammetric software systems for stereo evaluation and orthorectification. It takes part in the ESA/JAXA-AO Program to evaluate the performance and potential of the three-line stereo scanner PRISM and the multispectral imaging sensor AVNIR-2 on-board the Japanese satellite ALOS as a principal investigator. The high geometric resolution of PRI...

  7. Prism therapy and visual rehabilitation in homonymous visual field loss.

    O'Neill, Evelyn C

    2011-02-01

    Homonymous visual field defects (HVFD) are common and frequently occur after cerebrovascular accidents. They significantly impair visual function and cause disability particularly with regard to visual exploration. The purpose of this study was to assess a novel interventional treatment of monocular prism therapy on visual functioning in patients with HVFD of varied etiology using vision targeted, health-related quality of life (QOL) questionnaires. Our secondary aim was to confirm monocular and binocular visual field expansion pre- and posttreatment.

  8. Prism therapy and visual rehabilitation in homonymous visual field loss.

    O'Neill, Evelyn C

    2012-02-01

    PURPOSE: Homonymous visual field defects (HVFD) are common and frequently occur after cerebrovascular accidents. They significantly impair visual function and cause disability particularly with regard to visual exploration. The purpose of this study was to assess a novel interventional treatment of monocular prism therapy on visual functioning in patients with HVFD of varied etiology using vision targeted, health-related quality of life (QOL) questionnaires. Our secondary aim was to confirm monocular and binocular visual field expansion pre- and posttreatment. METHODS: Twelve patients with acquired, documented HVFD were eligible to be included. All patients underwent specific vision-targeted, health-related QOL questionnaire and monocular and binocular Goldmann perimetry before commencing prism therapy. Patients were fitted with monocular prisms on the side of the HVFD with the base-in the direction of the field defect creating a peripheral optical exotropia and field expansion. After the treatment period, QOL questionnaires and perimetry were repeated. RESULTS: Twelve patients were included in the treatment group, 10 of whom were included in data analysis. Overall, there was significant improvement within multiple vision-related, QOL functioning parameters, specifically within the domains of general health (p < 0.01), general vision (p < 0.05), distance vision (p < 0.01), peripheral vision (p < 0.05), role difficulties (p < 0.05), dependency (p < 0.05), and social functioning (p < 0.05). Visual field expansion was shown when measured monocularly and binocularly during the study period in comparison with pretreatment baselines. CONCLUSIONS: Patients with HVFD demonstrate decreased QOL. Monocular sector prisms can improve the QOL and expand the visual field in these patients.

  9. Controllable Sonar Lenses and Prisms Based on ERFs

    Bar-Cohen, Yoseph; Sherrit, Stewart; Chang, Zensheu; Bao, Xiaoqi; Paustian, Iris; Lopes, Joseph; Folds, Donald

    2004-01-01

    Sonar-beam-steering devices of the proposed type would contain no moving parts and would be considerably smaller and less power-hungry, relative to conventional multiple-beam sonar arrays. The proposed devices are under consideration for installation on future small autonomous underwater vehicles because the sizes and power demands of conventional multiple-beam arrays are excessive, and motors used in single-beam mechanically scanned systems are also not reliable. The proposed devices would include a variety of electrically controllable acoustic prisms, lenses, and prism/lens combinations both simple and compound. These devices would contain electrorheological fluids (ERFs) between electrodes. An ERF typically consists of dielectric particles floating in a dielectric fluid. When an electric field is applied to the fluid, the particles become grouped into fibrils aligned in rows, with a consequent increase in the viscosity of the fluid and a corresponding increase in the speed of sound in the fluid. The change in the speed of sound increases with an increase in the applied electric field. By thus varying the speed of sound, one varies the acoustic index of refraction, analogously to varying the index of refraction of an optical lens or prism. In the proposed acoustic devices, this effect would be exploited to control the angles of refraction of acoustic beams, thereby steering the beams and, in the case of lenses, controlling focal lengths.

  10. Performance analysis of the 840 MWt PRISM reference burner core

    The General Electric PRISM (Power Reactor, Innovative Small Module) is a modular, pool-type sodium-cooled fast reactor employing innovative, passive features to provide an extremely high level of public safety. A PRISM power block consists of two 840 MWt reactor modules, each with a vessel diameter of 9.15 m (30 ft), tied to a turbine generator and producing 622 MWe. A full-size plant consists of three power blocks producing 1866 MWe of electrical power. Two core configurations have been analyzed. The reference is a 'burner' core (conversion ratio of 0.8) and the alternative is a breakeven' core (plutonium consumption balanced by plutonium generation). The core nuclear designs are largely governed by passive safety and reactivity control issues. The key features employed to produce the desired passive safety characteristics are: a small core with a tight restraint system, the use of metallic U-Pu-Zr fuel, control rod withdrawal limiters (rod stops) and gas expansion modules (GEMs). A passive reactor vessel auxiliary cooling system (RVACS) assures safety-grade decay heat removal. This paper summarizes the operational and safety performance of the 840 MWt PRISM modular reactor, with emphasis on the reference burner core. (author)

  11. The LHCb Run Control

    Alessio, F.; Barandela, M. C.; Callot, O.; Duval, P.-Y.; Franek, B.; Frank, M.; Galli, D.; Gaspar, C.; Herwijnen, E. v.; Jacobsson, R.; Jost, B.; Neufeld, N.; Sambade, A.; Schwemmer, R.; Somogyi, P.

    2010-04-01

    LHCb has designed and implemented an integrated Experiment Control System. The Control System uses the same concepts and the same tools to control and monitor all parts of the experiment: the Data Acquisition System, the Timing and the Trigger Systems, the High Level Trigger Farm, the Detector Control System, the Experiment's Infrastructure and the interaction with the CERN Technical Services and the Accelerator. LHCb's Run Control, the main interface used by the experiment's operator, provides access in a hierarchical, coherent and homogeneous manner to all areas of the experiment and to all its sub-detectors. It allows for automated (or manual) configuration and control, including error recovery, of the full experiment in its different running modes. Different instances of the same Run Control interface are used by the various sub-detectors for their stand-alone activities: test runs, calibration runs, etc. The architecture and the tools used to build the control system, the guidelines and components provided to the developers, as well as the first experience with the usage of the Run Control will be presented

  12. The LHCb Run Control

    LHCb has designed and implemented an integrated Experiment Control System. The Control System uses the same concepts and the same tools to control and monitor all parts of the experiment: the Data Acquisition System, the Timing and the Trigger Systems, the High Level Trigger Farm, the Detector Control System, the Experiment's Infrastructure and the interaction with the CERN Technical Services and the Accelerator. LHCb's Run Control, the main interface used by the experiment's operator, provides access in a hierarchical, coherent and homogeneous manner to all areas of the experiment and to all its sub-detectors. It allows for automated (or manual) configuration and control, including error recovery, of the full experiment in its different running modes. Different instances of the same Run Control interface are used by the various sub-detectors for their stand-alone activities: test runs, calibration runs, etc. The architecture and the tools used to build the control system, the guidelines and components provided to the developers, as well as the first experience with the usage of the Run Control will be presented

  13. Stabilization of a self-referenced, prism-based, Cr:forsterite laser frequency comb using an intracavity prism

    The frequency comb from a prism-based Cr:forsterite laser has been frequency stabilized using intracavity prism insertion and pump power modulation. Absolute frequency measurements of a CW fiber laser stabilized to the P(13) transition of acetylene demonstrate a fractional instability of ∼2x10-11 at a 1 s gate time, limited by a commercial Global Positioning System (GPS)-disciplined rubidium oscillator. Additionally, absolute frequency measurements made simultaneously using a second frequency comb indicate relative instabilities of 3x10-12 for both combs for a 1 s gate time. Estimations of the carrier-envelope offset frequency linewidth based on relative intensity noise and the response dynamics of the carrier-envelope offset to pump power changes confirm the observed linewidths.

  14. Local Seismicity Recorded by ChilePEPPER: Implications for Dynamic Accretionary Prism Response and Long-term Prism Evolution

    de Moor, A.; Trehu, A. M.; Tryon, M. D.

    2015-12-01

    To investigate the dynamic response of the outer accretionary wedge updip from the patch of greatest slip during the Mw8.8 2010 Maule earthquake, 10 Ocean Bottom Seismometers (OBS) were deployed from May 2012 to March 2013 in a small array with an inter-instrument spacing of ~12 km . Nine instruments were recovered, with 4 recording data on 3 intermediate-band 3-component seismometers and a differential pressure gauge and 5 recording data from absolute pressure gauges. [note: All instruments were also equipped with a fluid flow meter sensitive to flow rates as low as 0.0001 cm/yr in or out of the sediments. However, no flow signal was detected.] Here we present hypocenters for 569 local events that have S-P times less than 17 seconds (i.e. within ~125 km of the array) using hand-picked arrival times and a 1D velocity model derived from a 2D seismic refraction profile through the region (Moscoso et al 2011, EPSL). We analyze the distribution of seismicity in the context of published slip models, ChilePEPPER high-resolution seismic reflection data, critical taper analysis done by Cubas et al 2013 (EPSL), and offshore gravity data. The data show distinct segmentation within the outer prism. The northern section of the study area is characterized by a lack of seismicity, accretion of nearly all incoming sediment and a prism at critical taper. In contrast, abundant seismicity, significant sediment underthrusting at the deformation front and a prism below critical taper angle characterize the southern part of the study area. Both coseismic slip and post-rupture local seismicity can be related to density anomalies within the upper plate as revealed by free air gravity data corrected for the effects of bathymetry and the subducting plate. [ChilePEPPER - Project Evaluating Prism Post-Earthquake Response

  15. Running Boot Camp

    Toporek, Chuck

    2008-01-01

    When Steve Jobs jumped on stage at Macworld San Francisco 2006 and announced the new Intel-based Macs, the question wasn't if, but when someone would figure out a hack to get Windows XP running on these new "Mactels." Enter Boot Camp, a new system utility that helps you partition and install Windows XP on your Intel Mac. Boot Camp does all the heavy lifting for you. You won't need to open the Terminal and hack on system files or wave a chicken bone over your iMac to get XP running. This free program makes it easy for anyone to turn their Mac into a dual-boot Windows/OS X machine. Running Bo

  16. Fermilab DART run control

    DART is the high speed, Unix based data acquisition system being developed by Fermilab in collaboration with seven High Energy Physics Experiments. This paper describes DART run control, which has been developed over the past year and is a flexible, distributed, extensible system for the, control and monitoring of the data acquisition systems. We discuss the unique and interesting concepts of the run control and some of our experiences in developing it. We also give a brief update and status of the whole DART system

  17. Fermilab DART run control

    Oleynik, G.; Engelfried, J.; Mengel, L. [and others

    1995-05-01

    DART is the high speed, Unix based data acquisition system being developed by Fermilab in collaboration with seven High Energy Physics Experiments. This paper describes DART run control, which has been developed over the past year and is a flexible, distributed, extensible system for the, control and monitoring of the data acquisition systems. We discuss the unique and interesting concepts of the run control and some of our experiences in developing it. We also give a brief update and status of the whole DART system.

  18. Experimental study on the flow regimes past a confined prism undergoing self-sustained oscillations

    Highlights: • A experimental study is presented on the flow regimes past a confined prism. • Flow is 3D and involves the self-sustained motion of the prism. • Different regimes are indentified as a function of two control parameters. • Control parameters are the Reynolds number and the density ratio. • The concept has potential industrial applications. - Abstract: An experimental study based on Particle Image Velocimetry (PIV) is presented with the objective of studying the flow regimes that appear in the flow past a confined prism undergoing self-sustained oscillations at low Reynolds numbers (Re). The square-section prism, placed inside a 3D square cross-section vertical channel with a confinement ratio of 1/2.5, was tethered to the channel walls and, therefore, it was allowed to move freely transverse to the incoming flow. Re (based on the prism cross-section height) was varied in the range from 100 to 700. Three different prism to fluid density ratios (m∗) were considered: 0.56, 0.70, and 0.91. These two parameters, Re and m∗, were used to map the results obtained. In particular, it was found that five different regimes appear: (1) steady prism with steady recirculation bubble, (2) steady prism with unsteady vortex shedding wake, (3) large amplitude low frequency oscillating prism with unsteady vortex shedding wake, (4) small amplitude high frequency oscillating prism with unsteady vortex shedding wake, and (5) irregular/chaotic motion of both the prism and the wake. The PIV results and associated numerical simulations were used to analyze the different prism and wake states

  19. Redshift estimation from low-resolution prism SEDs with an NGST MOS

    Teplitz, Harry I.; Malumuth, Eliot; Woodgate, Bruce E.; Moseley, S. Harvey; Gardner, Jonathan P.; Kimble, Randy A.; Bowers, Charles W.; Kutyrev, Alexander S.; Fettig, Rainer K.; Wesenberg, Richard P.; Mentzell, John E.

    2000-01-01

    We discuss the utility of a low resolution prism as a component of a Multi-Object Spectrometer for NASA's proposed Next Generation Space Telescope (NGST). Low resolution prism spectroscopy permits simultaneous observation of the 0.6-5micron wavelength regime at R~50. To such data we can apply the modern techniques in spectral energy distribution (SED) fitting to determine source redshifts, sometimes called ``photometric redshifts''. Low resolution prism observations of galaxy SED's provide a ...

  20. Synthesis and Photocatalytic Activity of Ag3PO4 Triangular Prism

    Pengyu Dong; Yan Hao; Peiyang Gao; Entian Cui; Qinfang Zhang

    2015-01-01

    Ag3PO4 triangular prism was synthesized by a facile chemical precipitation approach by simply adjusting external ultrasonic condition. The as-synthesized Ag3PO4 triangular prism was characterized by X-ray diffraction pattern (XRD), field emission scanning electron microscopy (SEM), fourier transform infrared (FTIR) spectra, and ultraviolet-visible diffuse reflectance (UV-vis DRS) absorption spectra. The photocatalytic activity of Ag3PO4 triangular prism was evaluated by photodegradation of or...

  1. PriSM: a primer selection and matching tool for amplification and sequencing of viral genomes

    Yu, Qing; Ryan, Elizabeth M; Allen, Todd M.; Birren, Bruce W.; Henn, Matthew R.; Lennon, Niall J.

    2010-01-01

    Summary: PriSM is a set of algorithms designed to select and match degenerate primer pairs for the amplification of viral genomes. The design of panels of hundreds of primer pairs takes just hours using this program, compared with days using a manual approach. PriSM allows for rapid in silico optimization of primers for downstream applications such as sequencing. As a validation, PriSM was used to create an amplification primer panel for human immunodeficiency virus (HIV) Clade B.

  2. Left-Deviating Prism Adaptation in Left Neglect Patient: Reflexions on a Negative Result

    Jacques Luauté; Sophie Jacquin-Courtois; Jacinta O'Shea; Laure Christophe; Gilles Rode; Dominique Boisson; Yves Rossetti

    2012-01-01

    Adaptation to right-deviating prisms is a promising intervention for the rehabilitation of patients with left spatial neglect. In order to test the lateral specificity of prism adaptation on left neglect, the present study evaluated the effect of left-deviating prism on straight-ahead pointing movements and on several classical neuropsychological tests in a group of five right brain-damaged patients with left spatial neglect. A group of healthy subjects was also included for comparison purpos...

  3. Mortality Risk Prediction by Application of PRISM Scoring System in Pediatric Intensive Care Unit

    Mahdi Mohammadi; Afshin Fayyazi; Mohsen Raeisi; Noor Mohammad Noori; Ali Khajeh; Ghasem Miri-Aliabad

    2013-01-01

    Objective: The Pediatric Risk of Mortality (PRISM) score is one of the scores used by many pediatricians for prediction of the mortality risk in the pediatric intensive care unit (PICU). Herein, evaluate the efficacy of PRISM score in prediction of mortality rate in PICU.Methods: In this cohort study, 221 children admitted during an 18-month period to PICU, were enrolled. PRISM score and mortality risk were calculated. Follow up was noted as death or discharge. Results were analyzed by Kaplan...

  4. DYNAMIQUE DES PRISMES OROGÉNIQUES, LE RÔLE DES FLUIDES

    Deville, Eric

    2011-01-01

    The work presented is a dossier presented to anobyainaccreditation to supervise research (HDR). It concerns the role of fluids in orogenic prisms. The presentation is organized around three approaches: (1) an integrated approach to iconic sites: a mature accretionary prism (the prism of Barbados) and a chain collision (Western Alps), (2) a methodological approach, and (3) a thematic approach to study processes poorly understood and to discuss problems of structure and dynamics of convergent o...

  5. BC-5500与Abbott CD-3700全自动血细胞分析仪性能的比较分析

    吴立兵; 李德奎

    2010-01-01

    @@ 深圳迈瑞公司和美国雅培公司采用不同的检测原理分别生产了BC-5500和Abbott CD-3700血细胞分析仪,为了解这2种血细胞分析仪检测结果的准确性、精密度和一致性,本组对二者的临床检测结果进行了分析、比较.结果报告如下.

  6. Development and Clinical Evaluation of a Recombinant-Antigen-Based Cytomegalovirus Immunoglobulin M Automated Immunoassay Using the Abbott AxSYM Analyzer

    Maine, G T; Stricker, R; Schuler, M.; Spesard, J.; Brojanac, S.; Iriarte, B.; Herwig, K.; Gramins, T.; Combs, B.; Wise, J.; Simmons, H.; Gram, T.; Lonze, J.; Ruzicki, D.; Byrne, B

    2000-01-01

    A new microparticle enzyme immunoassay (MEIA), the Cytomegalovirus (CMV) Immunoglobulin M (IgM) test, was developed on the Abbott AxSYM analyzer. This test uses recombinant CMV antigens derived from portions of four structural and nonstructural proteins of CMV: pUL32 (pp150), pUL44 (pp52), pUL83 (pp65), and pUL80a (pp38). A total of 1,608 specimens from random volunteer blood donors (n = 300), pregnant women (n = 1,118), transplant recipients (n = 6), and patients with various clinical condit...

  7. Erythropoiesis: Short Report: Translation of Analysis Results between Serum Ferritin Assays, Ferritin RIA AmershamTM and Abbott AxSYMTM Ferritin.

    Milman, NILS; Byg, KELD-ERIK; Juul-Jørgensen, BIRGIT; Weis Bentzon, MICHAEL

    1999-01-01

    The serum ferritin assays, Ferritin RIA Amersham(TM) and Abbott AxSYM(TM) Ferritin were compared in order to translate values from one assay to the other. Serum ferritin was analysed with both assays in 102 samples. Logarithmic transformation of the results was performed in order to stabilize the variance. The relationship between the untransformed values was most exactly expressed by a proportionality: AxSYM Ferritin = 0.873 * RIA Ferritin. Due to this proportionality, the numerical difference between the assays increases with the ferritin concentration, although the percentage difference between the assays remains constant. PMID:11399562

  8. Group-delay Dispersion in Double-prism Pair and Limitation in Broadband Laser Pulses

    程昭; 赵卫

    2002-01-01

    A general expression of group-delay dispersion is obtained without any approximation for a pair of double prisms with an arbitrary apex angle. This expression also includes the change of dispersion resulting from change in insertion of the prism material into the beam by translating prism-pairs. The high-order dispersion can be calculated by means of this expression. The limitation for generation of negative group-delay dispersion by use of prism-pairs is presented for ultrashort laser pulses with broadband spectrum.

  9. Ray-optical negative refraction and pseudoscopic imaging with Dove-prism arrays

    Courtial, J.; Nelson, J

    2008-01-01

    A sheet consisting of an array of small, aligned Dove prisms can locally (on the scale of the width of the prisms) invert one component of the ray direction. A sandwich of two such Dove-prism sheets that inverts both transverse components of the ray direction is a ray-optical approximation to the interface between two media with refractive indices +n and –n. We demonstrate the simulated imaging properties of such a Dove-prism-sheet sandwich, including a demonstration of pseudoscopic imaging.

  10. PRISM -- A tool for modelling proton energy deposition in semiconductor materials

    This paper presents a description of, and test results from, a new PC based software simulation tool PRISM (Protons in Semiconductor Materials). The model describes proton energy deposition in complex 3D sensitive volumes of semiconductor materials. PRISM is suitable for simulating energy deposition in surface-barrier detectors and semiconductor memory devices, the latter being susceptible to Single-Event Upset (SEU) and Multiple-Bit Upset (MBU). The design methodology on which PRISM is based, together with the techniques used to simulate ion transport and energy deposition, are described. Preliminary test results used to analyze the PRISM model are presented

  11. A high throughput (>90%), large compensation range, single-prism femtosecond pulse compressor

    Kong, Lingjie

    2013-01-01

    We demonstrate a high throughput, large compensation range, single-prism femtosecond pulse compressor, using a single prism and two roof mirrors. The compressor has zero angular dispersion, zero spatial dispersion, zero pulse-front tilt, and unity magnification. The high efficiency is achieved by adopting two roof mirrors as the retroreflectors. We experimentally achieved ~ -14500 fs2 group delay dispersion (GDD) with 30 cm of prism tip-roof mirror prism separation, and ~90.7% system throughput with the current implementation. With better components, the throughput can be even higher.

  12. The spectral characteristics of the splitting angle for double Wollaston prism

    WU Wen-di; WANG Zhao-bing; WANG Hai-long; ZHANG Shan

    2009-01-01

    The spectral characteristics of the splitting angle and its asymmetry for double-Wollaston prism are analyzed theoretically. With the increase of the prism structure angle, the splitting angle of the double Wollaston prism and its asymmetry increase. However, the splitting angle decreases with the increase of the wavelength of incident light. The influence of the incident light wavelength on the splitting angle in the ultraviolet wave band is much greater than that in visible and near-infrared wave band. To verify the theoretical analysis, the characteristics of the double Wollaston prism are also studied experimentally.

  13. Run Sheldon Website

    Monserrat Nuñez, Pau

    2015-01-01

    [CATALÀ] Aquest projecte tracta sobre el desenvolupament de la web del joc per iPhone i Android, Run Sheldon. La web ha de tenir un comportament com el del joc i ha de ser compatible per tot tipus de dispositius.

  14. Running Wheel for Earthworms

    Wilson, W. Jeffrey; Johnson, Brandon A.

    2016-01-01

    We describe the construction and use of a running wheel responsive to the movement of the earthworm. The wheel employs readily available, inexpensive components and is easily constructed. Movement of the wheel can be monitored visually or via standard behavioral laboratory computer interfaces. Examples of data are presented, and possibilities for use in the teaching classroom are discussed.

  15. Ultrafine Metal-Organic Right Square Prism Shaped Nanowires.

    Otake, Ken-Ichi; Otsubo, Kazuya; Sugimoto, Kunihisa; Fujiwara, Akihiko; Kitagawa, Hiroshi

    2016-05-23

    We report the structural design and control of electronic states of a new series of ultrafine metal-organic right square prism-shaped nanowires. These nanowires have a very small inner diameter of about 2.0 Å, which is larger than hydrogen and similar to xenon atomic diameters. The electronic states of nanowires can be widely controlled by substitution of structural components. Moreover, the platinum homometallic nanowire shows a 100 times higher proton conductivity than a palladium/platinum heterometallic one depending on the electronic states. PMID:27080935

  16. Deformation of the Nankai Trough inner accretionary prism: The role of inherited structures

    Boston, Brian; Moore, Gregory F.; Jurado, María. José; Sone, Hiroki

    2016-02-01

    Accretionary prisms commonly grow seaward, with the strata of the inner prism consisting of older, previously accreted outer prism rocks overlain by thick fore-arc basin strata. We focus on the Nankai Trough inner accretionary prism using three-dimensional (3-D) seismic data and logging data from the Integrated Ocean Drilling Program (IODP). We update the 3-D seismic volume using well velocity data to better constrain deeper horizons. Interpretation of these horizons reveals multiple folds with axial surfaces that strike near parallel to modern outer prism thrust faults, and we interpret that these folds formed as a result of thrust faulting. Reactivation of one inner prism thrust fault continued until at least ˜0.44 Ma, after the modern fore-arc basin formed, indicating that the inner prism had continued deformation until that time. Structural restorations of these folded seismic horizons demonstrate that ˜580 m of slip occurred on this steeply dipping reactivated thrust after fore-arc basin formation. Structural interpretation and analysis of logging-while-drilling data, including borehole images, in the deep inner prism revealed intense deformation of a generally homogenous lithology characterized by bedding that dips steeply (60°-90°), intersected by faults and fractures that have a range of dips and densities. Our study of the deep Kumano Basin provides new insights into the structure of the inner prism and reveals that although the inner prism has partially preserved inherited outer prism structures, these older folds and faults are steeply rotated and cut by multiple fracture populations during subsequent deformation.

  17. Rails: Up and Running

    Tate, Bruce A; Carlson, Lance

    2008-01-01

    In just a matter of days, you can develop powerful web applications with Rails that once took weeks or months to produce with other web frameworks. Find out how with Rails: Up and Running. Perfect for beginning web developers, this new edition teaches the basics of installing and using Rails 2.1 and the Ruby scripting language, and covers just about everything you need to develop your own Rails applications quickly.

  18. The Running Athlete

    Henning, P. Troy

    2014-01-01

    Context: Pelvic stress fractures, osteitis pubis, and snapping hip syndrome account for a portion of the overuse injuries that can occur in the running athlete. Evidence Acquisition: PubMed searches were performed for each entity using the following keywords: snapping hip syndrome, coxa sultans, pelvic stress fracture, and osteitis pubis from 2008 to 2013. Topic reviews, case reports, case series, and randomized trials were included for review. Study Design: Clinical review. Level of Evidence...

  19. Comparison of the AdvanSure Human Papillomavirus Screening Real-Time PCR, the Abbott RealTime High Risk Human Papillomavirus Test, and the Hybrid Capture Human Papillomavirus DNA Test for the Detection of Human Papillomavirus

    Hwang, Yusun; Lee, Miae

    2012-01-01

    Background We evaluated the performance of various commercial assays for the molecular detection of human papillomavirus (HPV); the recently developed AdvanSure HPV Screening real-time PCR assay (AdvanSure PCR) and the Abbott RealTime High Risk HPV PCR assay (Abbott PCR) were compared with the Hybrid Capture 2 HPV DNA Test (HC2). Methods All 3 tests were performed on 177 samples, and any sample that showed a discrepancy in any of the 3 tests was genotyped using INNO-LiPA HPV genotyping and/or...

  20. The Color Splitting System for TV Cameras - XYZ Prism

    E. Kostal

    2001-09-01

    Full Text Available One of the dominant aspects, which prejudices the quality of colorimage reproduction, is the first operation in TV chain - scanning. Upto this day, the color splitting system, working in RGB colorimetricsystem, is still entirely used. The existence of negative parts of thecolor matching functions r(l, g(l, b(l causes complications byoptical separation of partial pictures R, G, B in classic scanningsystem. It leads to distortion of reproduction of color images.However, the specific technical and scientific applications, where thecolor carries the substantial part of information (cosmic development,medicine, demand high fidelity of color reproduction. This articlesubmits the results of the design of the color splitting system workingin XYZ colorimetric system (next only XYZ prism. Shortly the way toobtain theoretical spectral reflectances of partial filters of XYZprism is described. Further, these filters are approximated by realoptical interference filters and the geometry of XYZ prism isestablished. Finally, the results of the colorimetric distortion testof proposed scanning system are stated.

  1. The PRISM (Pliocene Palaeoclimate) reconstruction: Time for a paradigm shift

    Dowsett, Harry J.; Robinson, Marci M.; Stoll, Danielle K.; Foley, Kevin M.; Johnson, Andrew L. A.; Williams, Mark; Riesselman, Christina

    2013-01-01

    Global palaeoclimate reconstructions have been invaluable to our understanding of the causes and effects of climate change, but single-temperature representations of the oceanic mixed layer for data–model comparisons are outdated, and the time for a paradigm shift in marine palaeoclimate reconstruction is overdue. The new paradigm in marine palaeoclimate reconstruction stems the loss of valuable climate information and instead presents a holistic and nuanced interpretation of multi-dimensional oceanographic processes and responses. A wealth of environmental information is hidden within the US Geological Survey's Pliocene Research,Interpretation and Synoptic Mapping (PRISM) marine palaeoclimate reconstruction, and we introduce here a plan to incorporate all valuable climate data into the next generation of PRISM products. Beyond the global approach and focus, we plan to incorporate regional climate dynamics with emphasis on processes, integrating multiple environmental proxies wherever available in order to better characterize the mixed layer, and developing a finer time slice within the Mid-Piacenzian Age of the Pliocene, complemented by underused proxies that offer snapshots into environmental conditions. The result will be a proxy-rich, temporally nested, process-oriented approach in a digital format—a relational database with geographic information system capabilities comprising a three-dimensional grid representing the surface layer, with a plethora of data in each cell.

  2. The PRISM (Pliocene palaeoclimate) reconstruction: time for a paradigm shift.

    Dowsett, Harry J; Robinson, Marci M; Stoll, Danielle K; Foley, Kevin M; Johnson, Andrew L A; Williams, Mark; Riesselman, Christina R

    2013-10-28

    Global palaeoclimate reconstructions have been invaluable to our understanding of the causes and effects of climate change, but single-temperature representations of the oceanic mixed layer for data-model comparisons are outdated, and the time for a paradigm shift in marine palaeoclimate reconstruction is overdue. The new paradigm in marine palaeoclimate reconstruction stems the loss of valuable climate information and instead presents a holistic and nuanced interpretation of multi-dimensional oceanographic processes and responses. A wealth of environmental information is hidden within the US Geological Survey's Pliocene Research, Interpretation and Synoptic Mapping (PRISM) marine palaeoclimate reconstruction, and we introduce here a plan to incorporate all valuable climate data into the next generation of PRISM products. Beyond the global approach and focus, we plan to incorporate regional climate dynamics with emphasis on processes, integrating multiple environmental proxies wherever available in order to better characterize the mixed layer, and developing a finer time slice within the Mid-Piacenzian Age of the Pliocene, complemented by underused proxies that offer snapshots into environmental conditions. The result will be a proxy-rich, temporally nested, process-oriented approach in a digital format-a relational database with geographic information system capabilities comprising a three-dimensional grid representing the surface layer, with a plethora of data in each cell. PMID:24043866

  3. 全自动血液分析仪Sysmex XE-2100与Abbott CD-3700的比较分析

    范华杰; 凌励; 周道银

    2006-01-01

    目的比较分析Sysmex XE-2100和Abbott CD-3700 2类全自动血液分析仪各项检测参数结果的精确度和相关性.方法选取EDTA-K2抗凝静脉全血,对2台仪器进行精密度和相关性的检测.结果精密度测定,Sysmex XE-2100血细胞计数各参数变异系数(CV)值位于0.24%~3.56%之间,白细胞分类各参数CV值位于0.66%~37.04%之间;Abbott CD-3700血细胞计数各参数CV值位于0.30%~4.37%之间,白细胞分类各参数CV值位于0.92%~27.91%之间.2台仪器间血细胞计数各参数相关系数的平方(r2)位于0.931 2~0.998 7之间.结论 2台仪器各参数精密度符合设计范围,两者之间相关性较好.

  4. WRF nature run

    The Weather Research and Forecast (WRF) model is a model of the atmosphere for mesoscale research and operational numerical weather prediction (NWP). A petascale problem for WRF is a nature run that provides very high-resolution 'truth' against which more coarse simulations or perturbation runs may be com-pared for purposes of studying predictability, stochastic parameterization, and fundamental dynamics. We carried out a nature run involving an idealized high resolution rotating fluid on the hemisphere, at a size and resolution never before attempted, and used it to investigate scales that span the k-3 to k-5/3 kinetic energy spectral transition, via simulations. We used up to 15,360 processors of the New York Blue IBM BG/L machine at Stony Brook Uni-versity and Brookhaven National Laboratory. The grid we employed has 4486 by 4486 horizontal grid points and 101 vertical levels (2 billion cells) at 5km resolution; this is 32 times larger than the previously largest 63 million cell 2.5km resolution WRF CONUS benchmark [10]). To solve a problem of this size, we worked through issues of parallel I/O and scalability and employed more processors than have ever been used in a WRF run. We achieved a sustained 3.4 Tflop/s on the New York Blue sys-tem, inputting and then generating an enormous amount of data to produce a scientifically meaningful result. More than 200 GB of data was input to initialize the run, which then generated output datasets of 40 GB each simulated hour. The cost of output was considered a key component of our investigation. Then we ran the same problem on more than 12K processors of the XT4 system at NERSC and achieved 8.8 Tflop/s. Our primary result however is not just scalability and a high Tflop/s number, but capture of atmosphere features never before represented by simulation, and taking an important step towards understanding weather predict-ability at high resolution

  5. ABBOTTARCHITECTC16000全自动生化分析仪性能评价%Evaluation on performance of ABBOTT ARCHITECT C16000 automatic biochemistry analyzer

    张娟; 蒋小燕; 李顺君; 黄文芳

    2014-01-01

    Objective To evaluate the main performance of ABBOTT ARCHITECT C160000 biochemistry analyzer,and to judge whether the performance meets the laboratory requirement.Methods According to the clinical laboratory management meth-od and the requirement of accreditation of national laboratory,the precision,accuracy and linearity of the 17 test items(Urea,Cre, UA,Glu,etc.)were analyzed by the CLSI EP5-A2 document,CLSI EP9-A2 document and CLSI EP6-P document;the quotative ref-erence ranges of the 17 test items were verified.Results The coefficient of variation(CV)in within-batch precision of Urea,Cre, UA,Glu,etc.was ≤1/4 CLIA′88 standard and CV in the between-batch precision ≤1/3CLIA′88 standard;in the accuracy test,the relative bias of the 17 test items≤1/2CLIA′88 standard;the linearity of the 17 items was good(r2 >0.95);the cited reference range of various detection items was suitable.Conclusion The performance of the ABBOTT ARCHITECT C160000 automatic biochem-istry analyzer meets the laboratory demand.%目的:对 ABBOTT ARCHITECT C16000生化分析仪主要性能进行评价,判断其是否能够满足本科实验室需求。方法依照实验室管理办法及国家实验室认可的要求,分别采用美国临床和实验室标准化协会(CLSI)的 EP5-A2、EP9-A2和EP6-A 文件评价方法分析尿素(Urea)、肌酐(Cre)、尿酸(UA)和葡萄糖(Glu)等17项检测项目的精密度、准确度和线性;并对各检测项目引用的参考区间进行验证。结果 ABBOTT ARCHITECT C16000生化分析仪 Urea、Cre、UA、Glu 等17项检测项目批内精密度变异系数(CV)均小于或等1/4CLIA′88标准,批间精密度 CV 均小于或等于1/3CLIA′88标准;在准确度试验中,该17项检测项目的相对偏倚均小于或等于1/2CLIA′88标准;线性良好(r2>0.95);各检测项目引用的参考区间合适。结论 ABBOTT ARCHITECT C16000生化分析仪性能满足本实验室需求。

  6. Simultaneous adaptation of the thumb and index finger of the same hand to opposite prism displacements

    Schot, Willemijn D; Brenner, Eli; Smeets, Jeroen B J

    2014-01-01

    It only takes a few goal-directed hand movements to adapt one's movements to a prism-induced displacement of the visual scene. Adaptation to the displacement leads to errors in the opposite direction from the initial displacement when the prisms are removed. Such aftereffects are thought to arise fr

  7. Prism Foil from an LCD Monitor as a Tool for Teaching Introductory Optics

    Planinsic, Gorazd; Gojkosek, Mihael

    2011-01-01

    Transparent prism foil is part of a backlight system in LCD monitors that are widely used today. This paper describes the optical properties of the prism foil and several pedagogical applications suitable for undergraduate introductory physics level. Examples include experiments that employ refraction, total internal reflection, diffraction and…

  8. Investigating First Year Elementary Mathematics Teacher Education Students' Knowledge of Prism

    Bozkurt, Ali; Koc, Yusuf

    2012-01-01

    The purpose of this study was to investigate first year elementary mathematics teacher education students' knowledge of prism. For this goal, the participants were asked to define the geometric concept of prism. The participants were 158 first year elementary mathematics teacher education students from a public university in Southern Turkey. The…

  9. Prism foil from an LCD monitor as a tool for teaching introductory optics

    Transparent prism foil is part of a backlight system in LCD monitors that are widely used today. This paper describes the optical properties of the prism foil and several pedagogical applications suitable for undergraduate introductory physics level. Examples include experiments that employ refraction, total internal reflection, diffraction and image formation in a nontrivial way and are therefore particularly useful for active learning strategies.

  10. Hierarchically triangular prism structured Co3O4: Self-supported fabrication and photocatalytic property

    The formation of ammonium cobalt (II) phosphate was utilized to synthesize unprecedented 3D structures of Co3O4, triangular prisms and trunk-like structures, via a self-supported and organics-free method. The length of a triangular side of the prepared 3D triangular prisms is ~1...