UK PubMed Central (United Kingdom)
BackgroundAn abdominal aortic aneurysm (AAA) that is identified when the abdomen is imaged for some other reason is known as an incidental AAA. No population-based studies have...Full Text Available
International Nuclear Information System (INIS)
The Anisotropic Analytical Algorithm (AAA) is a new pencil beam convolution/superposition algorithm proposed by Varian for photon dose calculations. The configuration of AAA depends on linear accelerator design and specifications. The purpose of this study was to investigate the accuracy of AAA for an Elekta SL25 linear accelerator for small fields and intensity modulated radiation therapy (IMRT) treatments in inhomogeneous media. The accuracy of AAA was evaluated in two studies. First, AAA was compared both with Monte Carlo (MC) and the measurements in an inhomogeneous phantom simulating lung equivalent tissues and bone ribs. The algorithm was tested under lateral electronic disequilibrium conditions, using small fields (2x2 cm"2). Good agreement was generally achieved for depth dose and profiles, with deviations generally below 3% in lung inhomogeneities and below 5% at ...
2007-05-01
The Place of Ethics in Ireland and Elsewhere
British Library Electronic Table of Contents (United Kingdom)
Abstract: [public affairs, ethical currents, Ireland, social research ethics] Liam Frink is contributing editor of Ethical Currents, the AN column of the AAA Committee on Ethics.
2011-01-01
Management of Concomitant Cancer and Abdominal Aortic Aneurysm
UK PubMed Central (United Kingdom)
Background. The coexistence of neoplasm and abdominal aortic aneurysm (AAA) presents a real management challenge. This paper reviews the literature on the prevalence, diagnosis,...Full Text Available
International Nuclear Information System (INIS)
In July 2005 a new algorithm was released by Varian Medical Systems for the Eclipse planning system and installed in our institute. It is the anisotropic analytical algorithm (AAA) for photon dose calculations, a convolution/superposition model for the first time implemented in a Varian planning system. It was therefore necessary to perform validation studies at different levels with a wide investigation approach. To validate the basic performances of the AAA, a detailed analysis of data computed by the AAA configuration algorithm was carried out and data were compared against measurements. To better appraise the performance of AAA and the capability of its configuration to tailor machine-specific characteristics, data obtained from the pencil beam convolution (PBC) algorithm implemented in Eclipse were also added in the comparison. Since the purpose of the paper is to address the basic performances of ...
2006-03-21
UK PubMed Central (United Kingdom)
The two categories of anti-albumin antibodies (AAA), namely precipitins (AA-P) and agglutinins (AA-Aggl), were investigated in 260 patients with morphologically diagnosed chronic liver diseases (CLD)....Full Text Available
1981-02-01
British Library Electronic Table of Contents (United Kingdom)
Purpose - This paper seeks to deal with the history of Research and Development (R&D) management. It takes the history of the R&D Department of the Royal Philips Electronics of The Netherlands as an example to unravel the dynamics behind industrial R&D management. Design/methodology/approach - This paper is based upon historical and theoretical studies on industrial R&D institutions and research cultures. Findings - The paper proposes that the directors of the Philips R&D Department continually shaped and reshaped the organization in order to retain researchers with creative ideas, and to stimulate innovativeness. The R&D-management was the outcome of a search process that comprehended a mixture of scientific and industrial (management) skills, knowledge and experti...
2007-01-01
Michael C. Appel Dr. Myrlene Staten Dr. Olivier Blondel Dr. Philip Smith Dr. Ronald Margolis Dr. Salvatore Sechi Dr. Sanford Garfield Dr. Saul Malozowski Dr. Sheryl Sato Dr....
2011-08-28
Improvement of banana through biotechnology and mutation breeding
International Nuclear Information System (INIS)
Protocols were standardized for in vitro propagation of several elite and diverse banana accessions using shoot tip explants. Tissue culture raised plants were field planted at multiple locations. Studies were undertaken for the induction of mutations using multiple shoot cultures of six selected cultivars, Shreemanti (AAA), Basrai (AAA), Lal Kela (AAA), Rasthali (AAB), Karibale Monthan (ABB) and a wild diploid (BB). These shoot cultures were irradiated at different doses of gamma rays (0-100 Gy) and subcultured thrice (up to M_1V_3) to separate shimeras, followed by induction of rooting (M_1V_4). In general, the rate of multiplication had a negative association with the dose of gamma rays. Enhanced multiplication of shoots was noticed at lower doses. The proliferation of shoots was arrested beyond 50 Gy and a dose of 70 Gy was completely lethal for all the genotypes studied. The rooted plantlets were hardened in the green ...
1998-10-01
Two types of evacuated tube solar collectors have been operated in space heating, cooling and domestic hot water heating systems in Colorado State University Solar House I. An experimental collector from Corning Glass Works supplied heat to the system from January 1977 through February 1978, and an experimental collector from Philips Research Laboratory, Aachen, which is currently in use, has been operating since August 1978. A flat absorber plate inside a single-walled glass tube is used in the Corning design, whereas heat is conducted through a single glass wall to an external heat exchanger plate in the Philips collector. In comparison with conventional flat-plate collectors, both types show reduced heat losses and improved efficiency. For space heating and hot water supply in winter, the solar delivery efficiency of the Corning collector ranged from 49% to 60% of the incident solar energy. The portion of the space heating and domestic hot ...
1979-01-01
Investigation of amine amino acid salts for carbon dioxide absorption
Energy Technology Data Exchange (ETDEWEB)
The carbon dioxide capture potential of amine amino acid salts (AAAS), formed by mixing equinormal amounts of amino acids; e.g. glycine. B-alanine and sarcosine, with an organic base; 3-(methylamino)propylamine (MAPA), was assessed by comparison with monoethanolamine (MEA), and with amino acid salt (AAS) from amino acid neutralized with an inorganic base; potassium hydroxide (KOH). Carbon dioxide absorption and desorption experiments were carried out on the solvent systems at 40{sup o}C and 80{sup o}C respectively. Experimental results showed that amine amino acid salts have similar CO{sub 2} absorption properties to MEA of the same concentration. They also showed good signs of stability during the experiments. Amino acid salt from an inorganic base, KOH, showed lower performance in CO{sub 2} absorption than the amine amino acid salts (AAAS) mainly due to a lower equilibrium temperature sensitivity. AAAS showed better ...
2010-09-15
Sep 6, 2011 ... Investigators: Philip A. Townsend (PI, U. Wisconsin), Angelica L. .... Chris Funk ( co-PI,1), Christa Peters-Lidard (2), Molly Brown (2), Dennis Lettenmaier (3) ... T. Engman (NASA/GSFC/SAIC), Bowser (BoR), R. Stodt (BoR/TSC), ...
Distributed multiprocessor system runs on 68000-based VME bus hardware
Energy Technology Data Exchange (ETDEWEB)
Using the Philips DRM distributed real-time multiprocessing system, designers can implement high-performance computer systems using VME hardware and the C programming language. The system provides a virtual-processing environment in which several 68000 CPUs share the workload. There are no centralized components, and tasks can be assumed by the rest of a system in the event of an individual processor's failure.
1984-04-19
International Nuclear Information System (INIS)
The purpose of this work was to study and quantify the differences in dose distributions computed with some of the newest dose calculation algorithms available in commercial planning systems. The study was done for clinical cases originally calculated with pencil beam convolution (PBC) where large density inhomogeneities were present. Three other dose algorithms were used: a pencil beam like algorithm, the anisotropic analytic algorithm (AAA), a convolution superposition algorithm, collapsed cone convolution (CCC), and a Monte Carlo program, voxel Monte Carlo (VMC++). The dose calculation algorithms were compared under static field irradiations at 6 MV and 15 MV using multileaf collimators and hard wedges where necessary. Five clinical cases were studied: three lung and two breast cases. We found that, in terms of accuracy, the CCC algorithm performed better overall than AAA compared to VMC++, but AAA remains an attractive ...
2007-07-07
International Nuclear Information System (INIS)
The purpose of this work was to study and quantify the differences in dose distributions computed with some of the newest dose calculation algorithms available in commercial planning systems. The study was done for clinical cases where large density inhomogeneities were present. Three dose algorithms were used: a pencil beam like algorithm, the anisotropic analytic algorithm (AAA), a convolution superposition algorithm, collapsed cone convolution (CCC) and a Monte Carlo program, voxel Monte Carlo (VMC++). The dose calculation algorithms were compared under static field irradiations at 6 MV and 15 MV using multileaf collimators and hard wedges where necessary. Five clinical cases were studied: three lung and two breast cases. We found that the CCC algorithm performed overall better than AAA compared to VMC++, but AAA remains an attractive option for routine use in the clinic due to its short computation times. Dose ...
2007-06-01
Radiochemistry at the Philips Research Laboratories, Eindhoven, The Netherlands
International Nuclear Information System (INIS)
The activities of the radiochemical section (part of the Analytical Chemistry Group) deal mostly with problems of composition. Activation analysis with thermal neutrons serves for most of the trace element analyses either with or without chemical separations. Ge(Li) spectrometry has been increasingly automated so that many analyses can now be performed by relatively unskilled personnel. In a number of analyses an A.V.F.-cyclotron was employed: such an accelerator can deliver not only different types of charged particles at variable energies but also fast neutrons. (T.G.).
1977-01-01
Quantitative density measurements from a real-time neutron radiography system
Energy Technology Data Exchange (ETDEWEB)
An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation.
1986-01-01
Quantitative density measurements from a real-time neutron radiography system
International Nuclear Information System (INIS)
An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation.
1986-11-16
Tissue Heterogeneity in IMRT Dose Calculation for Lung Cancer
British Library Electronic Table of Contents (United Kingdom)
The aim of this study was to evaluate the differences in accuracy of dose calculation between 3 commonly used algorithms, the Pencil Beam algorithm (PB), the Anisotropic Analytical Algorithm (AAA), and the Collapsed Cone Convolution Superposition (CCCS) for intensity-modulated radiation therapy (IMRT). The 2D dose distributions obtained with the 3 algorithms were compared on each CT slice pixel by pixel, using the MATLAB code (The MathWorks, Natick, MA) and the agreement was assessed with the gamma function. The effect of the differences on dose-volume histograms (DVHs), tumor control, and normal tissue complication probability (TCP and NTCP) were also evaluated, and its significance was quantified by using a nonparametric test. In general PB generates regions of over-dosage both in the l...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
Banana (Musa acuminata Colla AAA) peel extracts obtained in this work had a high capacity to scavenge 2,2-diphenyl-1-picrylhydrazyl (DPPH) and 2,2prime-azino-bis(3-ethylbenzothiazoline)-6-sulfonic acid (ABTS+) free radicals, and they were also good lipid peroxidation inhibitors. Acetone:water extracts were considerably more effective (compared with methanol, ethanol, acetone, water, methanol:water or ethanol:water) at inhibiting the peroxidation of lipids in the b-carotene/linoleic acid system or scavenging free radicals. However, aqueous extracts had a high capacity to protect lipids from oxidation in the thiobarbituric acid reactive substances (TBARS) test, as well as in the b-carotene bleaching assay. In addition, acetone:water most efficiently extracted all extractable components (54+-...
2010-01-01
Study of the light yield of LuAP:Ce scintillating crystals
Energy Technology Data Exchange (ETDEWEB)
We have obtained optically clear samples of LuAP:Ce from the Institute of Physical Research, Ashtarak, Armenia, measuring up to 5x5x40 mm{sup 3}. The photo electron yield for a number of theses samples was measured with a Philips XP2020Q photomultiplier tube, and 556 photo electrons per MeV was obtained for the best samples. This is comparable to what is obtained from BGO crystals under the same condition, but a factor of 5 less than what is obtained with an LSO sample of similar dimensions. The light in LuAP:Ce increases with cerium concentration between 0.13 and 0.47%.
1996-12-31
Recent developments: Washington focus
International Nuclear Information System (INIS)
November was a quiet month in Washington. Although Congress has recessed until 1991, the Senate filled vacancies in party leadership positions created by November's elections. The House is expected to proceed with its changes in early December. The Nuclear Energy Forum was held in Washington, DC on November 11-14 to discuss the status of the nuclear industry in the USA. The Forum, held in conjunction with the American Nuclear Society's annual meeting, assembled a large number of CEO's from US, European, and Far Eastern utilities and vendors. The meeting concluded with an announcement by Philip Bayne, President of NYPA and chairman of the Nuclear Power Oversight Committee (NPOC), of the results of a year-long NPOC study entitled a open-quotes Strategic Plan for Building New Nuclear Power Plants.close quotes.
Interinstitutional Variations in Planning for Stereotactic Body Radiation Therapy for Lung Cancer
British Library Electronic Table of Contents (United Kingdom)
Purpose: The aim of this study was to assess interinstitutional variations in planning for stereotactic body radiation therapy (SBRT) for lung cancer before the start of the Japan Clinical Oncology Group (JCOG) 0403 trial.Methods and Materials: Eleven institutions created virtual plans for four cases of solitary lung cancer. The created plans should satisfy the target definitions and the dose constraints for the JCOG 0403 protocol.Results: FOCUS/XiO (CMS) was used in six institutions, Eclipse (Varian) in 3, Cadplan (Varian) in one, and Pinnacle3 (Philips/ADAC) in one. Dose calculation algorithms of Clarkson with effective path length correction and superposition were used in FOCUS/XiO; pencil beam convolution with Batho power law correction was used in Eclipse and Cadplan; and collapsed co...
2007-01-01
Initiation of conformal radiotherapy with a multileaf-collimator - An approach to clinical routine
International Nuclear Information System (INIS)
The implementation of a three-dimensional conformal radiotherapy facility in the radiotherapy department of the Heinrich Heine University is described. Complex radiotherapy techniques with commercially available networked systems are introduced to improve clinical work. Over 18 month we have gained clinical experience with a PHILIPS Multileaf Collimator (MLC) mounted on a SL 25 linear accelerator. For a limited period the MLC was used as a conventional blocking device. The standard MLC-shapes are controlled with a stand-alone computer system. In addition, a three-dimensional treatment planning system (3-D-TPS / TMS-Radix, Helax AB) based on convolution/superposition algorithms was recently installed. Treatment optimization is achieved using static field arrangements with complete volumetric computerized tomographic patient data for 3-D-TPS. Conformal adaptation of the 95%-isodose to the Planning Target Volume (PTV, ICRU 50) results in MLC-field-shaping concerning ...
1995-10-01
Tissue Heterogeneity in IMRT Dose Calculation for Lung Cancer
International Nuclear Information System (INIS)
The aim of this study was to evaluate the differences in accuracy of dose calculation between 3 commonly used algorithms, the Pencil Beam algorithm (PB), the Anisotropic Analytical Algorithm (AAA), and the Collapsed Cone Convolution Superposition (CCCS) for intensity-modulated radiation therapy (IMRT). The 2D dose distributions obtained with the 3 algorithms were compared on each CT slice pixel by pixel, using the MATLAB code (The MathWorks, Natick, MA) and the agreement was assessed with the ? function. The effect of the differences on dose-volume histograms (DVHs), tumor control, and normal tissue complication probability (TCP and NTCP) were also evaluated, and its significance was quantified by using a nonparametric test. In general PB generates regions of over-dosage both in the lung and in the tumor area. These differences are not always in DVH of the lung, although the Wilcoxon test indicated significant differences in 2 of 4 patients. Disagreement in the ...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
The Project ``Middle School Integrated Science, Mathematics and Technology Curriculum`` had two goals: (1) to survey the literature of energy education; and (2) to develop a theme for a possible integrated middle school energy based curriculum. We aimed to respond to the challenge of developing thematic integrated curricula as advocated by the NSTA, AAAS and other organizations analyzing the future of American science and mathematics education. The survey of middle school energy curriculum materials has been completed. A list of the resources surveyed are included in this report. Though many energy based curriculum materials have been produced, none of them appears to be broadly disseminated throughout the country. Some energy based curriculum materials are far less well developed than others. We found that an integrated set of modular materials concerning the energy based theme of light and optics does not now exist. If they were developed, they could be broadly ...
1994-03-01
Homogeneity for highly asymmetric fields has been studied for a Siemens PRIMUS linear accelerator. The flattening filter has a radius smaller than the primary collimator one, creating inhomogeneities that affect large fields in areas far from the collimator axis, and asymmetric fields with large offset. Profiles and absolute dose have been measured in fields with two jaws at maximal position (20 cm) and the other two at maximal overtravel (10 cm.), corresponding to 10 x 10 fields with extreme offset. Profiles have a remarkable gradient decreasing towards the beam edge, making these fields unsuitable for treatments. Results show that the design of the primary collimator and flattening filter assembly has direct consequences in homogeneity. This can have clinical consequences for treatments involving fields that include these inhomogeneous areas. Comparisons with the treatment planning system (Philips Pinnacle) calculations, that computes under the hypotheses of a ...
2005-01-01
The diagnosis of inflammatory muscular and vascular conditions using MRT with STIR sequences
International Nuclear Information System (INIS)
The role of MRT in the prebiopsy diagnosis of muscular and vascular inflammatory conditions was evaluated prospectively and an optimal method of examination was investigated. 92 patients with a suspected diagnosis of myositis (60 cases) or vasculitis (32 cases) were examined, in each case two extremities were studied using transverse T_1 and T_2 weighted SE sequences and double echo STIR sequences on a 0.5 Tesla (56 patients) or 1.5 Tesla magnet (36 patients; T5/S15 Gyroscan, Philips). The site of the biopsy depended on the MRT findings. In 41 patients the suspected diagnosis was confirmed histologically, in two patients an infective myositis was diagnosed on clinical grounds despite negative histology. MRT demonstrated muscle oedema in 86% of patients. There were negative findings after immuno-suppressive therapy (two patients), in focal myositis (3 out of 4 patients) and in one of 7 patients with untreated vasculitis. Amongst 49 patients in whom the suspected ...
Energy Technology Data Exchange (ETDEWEB)
TiO{sub 2} is a vital material in several technologies including, photocatalysis, gas sensing, biomaterials and optical coatings. Among the several crystal structures of this oxide, rutile has the highest density and microhardness, the highest index of refraction and the highest temperature stability. The processing of dense polycrystalline materials often includes the addition of a liquid-forming phase at higher temperatures. This technique is known as liquid-phase sintering and has been studied extensively. Rutile boundaries containing an amorphous phase have been used to study boundary migration and grain-boundary grooving. Visible-light (VLM), scanning electron (SEM) and transmission electron microscopy (TEM) in addition to electron-backscatter diffraction (EBSD) and a focused-ion beam (FIB) tool were used to characterize boundary migration in rutile. EBSD analysis was carried out on a Philips XL30 FEG SEM equipped with a DigiView 1612 high-resolution, ...
2003-08-01
International Nuclear Information System (INIS)
Background and purpose: A series of phase I/II clinical trials are being initiated in several UK centres to explore the use of dose-escalated schedules for the treatment of non-small cell lung cancer (NSCLC). Among them the IDEAL-CRT trial (ISRCTN12155469) will investigate the introduction of individualised 'isotoxic' treatment schedules based on the relative mean lung normalised total dose (rNTDmean), an estimator related to lung toxicity. Since treatment planning will be performed using different treatment planning systems (TPSs), for the quality assurance of the trial we have carried out work to quantify the influence of dose calculation algorithms based on the determination of rNTDmean and on the choice of individualised prescription doses. Material and methods: Twenty-five patient plans with stage I, II and III NSCLC were calculated, with the same prescription dose, using the Adaptive Convolve (AC) and Collapsed Cone (CC) algorithms of the Pinnacle TPS, the pencil beam convolution ...
2010-12-01
The detection of rare mutations has many important applications, including risk assessment of drugs and chemicals, measuring environmental exposures to genotoxins, and cancer cell detection. A sensitive genotypic selection method has been developed that combines two different mutant allele selection techniques, MutEx enrichment and allele-specific competitive blocker PCR (ACB-PCR). This method was developed and evaluated for the detection of a CAA --> AAA mutation at codon 61 of the mouse H-ras gene. The MutEx enrichment is based on MutS binding to a mismatched basepair in heteroduplex DNA. The bound MutS protects the mutant allele from degradation during subsequent exonuclease treatment. ACB-PCR preferentially amplifies a mutant allele in a PCR reaction using a primer that has more mismatches to the wild-type allele than the mutant allele. By combining these two approaches, the codon 61 mutation was detected at mutant fractions as low as 1 in 10(7). This ...
1998-01-01
International Nuclear Information System (INIS)
A study was made investigate a relationship existing in the dentoskeletal framework and the soft tissue profile around the face, and compared the sexual differences between boys and girls having the normal occlusion in the mixed dentition. The lateral cephalograms were composed of 67 boys aged 10.3 years and 68 girls aged 10.4 years, respectively. By means of the lateral cephalograms, both the hard-and soft tissue structures were simultaneously analyzed, measured and evaluated by introducing the several reference items: S-N plane, palatal plane, mandibular plane, N-A line and A-P line for the dentoskeletal structures and N'-P' line for the soft tissue, and the 21 measuring points for the both structures. The significant findings were as follows: 1. In general the boys showed the larger nasal component dimension than did the girls, but the length and height of nose(N'-Prn and NA-Prn) showed the significant sexual difference among those when evaluated statistically. 2. The lip-thickness ...
1978-11-01
International Nuclear Information System (INIS)
Purpose: Three-dimensional rotational angiography (3DRA) is a new technique based on a rotational angiographic acquisition able to display arterial vessels in a 3D rendering mode. The system was mainly developed for neuroradiological evaluations but preliminary extracranial experiences have also been reported. The aim of our work was to compare the results of three-dimensional angiography of the carotid arteries done with high-flow injection of contrast medium from the aortic arch with the results of selective angiography. Materials and methods: Twenty patients underwent digital angiography of the supra-aortic vessels in order to quantify a stenosis of the carotid bifurcations previously detected at Doppler Ultrasound. Examinations were performed with the Philips Integris Allura system provided with the rotational angiography (RA) tool connected to a workstation for three-dimensional reconstruction able to display vessels in a 3D fashion (Volume Rendering, Shaded ...
International Nuclear Information System (INIS)
The focus of this study is to validate whether the sensitivity of dose distribution following the interface of different media can be used to distinguish between small variations of photon energy spectra in the context of the convolution/superposition algorithm in the polyenergetic implementation (Philips Pinnacle"3, ADAC Laboratories, Milpitas, CA). Calculations were performed in homogeneous water and heterogeneous lung/water phantoms. Spectra were generated, in which the weights of the low-, medium- and high-energy components were adjusted sequentially. The heterogeneity correction factor CF_l_u_n_g, the D_2_0/D_1_0 ratio for homogeneous water and logarithmic derivative in buildup region LD_b_u_i_l_d_u_p were assessed for their relative ability to discriminate between different spectra for various field sizes. In accordance with another study (Charland et al 2004), the superior discrimination ability of the CF_l_u_n_g and LD_b_u_i_l_d_u_p tests over the ...
2004-09-21
Interinstitutional Variations in Planning for Stereotactic Body Radiation Therapy for Lung Cancer
International Nuclear Information System (INIS)
Purpose: The aim of this study was to assess interinstitutional variations in planning for stereotactic body radiation therapy (SBRT) for lung cancer before the start of the Japan Clinical Oncology Group (JCOG) 0403 trial. Methods and Materials: Eleven institutions created virtual plans for four cases of solitary lung cancer. The created plans should satisfy the target definitions and the dose constraints for the JCOG 0403 protocol. Results: FOCUS/XiO (CMS) was used in six institutions, Eclipse (Varian) in 3, Cadplan (Varian) in one, and Pinnacle3 (Philips/ADAC) in one. Dose calculation algorithms of Clarkson with effective path length correction and superposition were used in FOCUS/XiO; pencil beam convolution with Batho power law correction was used in Eclipse and Cadplan; and collapsed cone convolution superposition was used in Pinnacle3. For the target volumes, the overall coefficient of variation was 16.6%, and the interinstitutional variations were not ...
2007-06-01
International Nuclear Information System (INIS)
The authors compared unenhanced and contrast-enhanced fast MRI and Computerized Tomography in the detection of liver metastases. Eleven patients with single or multiple hepatic lesions (42 in all) were submitted to V and magnetic resonance studies; T1- and T2- weighted TSE, T2-weighted TSE with fat suppression, unenhanced breath-hold TFE and early or delayed enhanced breath-hold TFE images were acquired with a 1.5 T superconductive magnet (Philips NT). The quantitative analysis of all magnetic resonance images was performed for contrast/noise ratio (CNR) and number of detected lesions; magnetic resonance and Computerized Tomography images were also compared qualitatively for lesion conspicuity, anatomical structure identification and artifacts. The results were compared with Student's test. Early enhanced breath-hold TFE was statistically superior to T1-weighted TSE (p = .0009), T2-weighted TSE (p = .01) and Computerized Tomography ( p = .0004) for lesion ...
1997-01-01
Energy Technology Data Exchange (ETDEWEB)
Purpose: Small suspicious breast lesions that are only visible at MR imaging were preoperatively marked with a hook wire under MR-guidance to allow the removal of the lesion with tissue-sparing surgery. Method: In all patients the suspicious lesions were marked preoperatively under MR guidance with a hook wire using a commercially available stereotactic device. Interventions were performed with MR guidance on a 1.0 T and on a 1.5 T system. Results: In 19 patients 22 lesions were localized. One lesion was missed and removed in a second procedure. The mean duration for localization was 66{+-}20 min (range 38-119 min). In two patients two lesions were localized. The mean deviation of the wire tip to the lesion was 2,0{+-}2,6 mm. In this series, 6 of 22 lesions were malignant. The mean diameter of the lesion was 7.6{+-}2.6 mm (range 3-14 mm). Conclusion: Suspicious breast lesions detectable only in MR imaging can be accurately localized with a hook wire preoperatively under MR control to ...
2000-09-01
International Nuclear Information System (INIS)
The goal of this work is to present a systematic Monte Carlo validation study on the clinical implementation of the enhanced dynamic wedges (EDWs) into the Pinnacle"3 (Philips Medical Systems, Fitchburg, WI) treatment planning system (TPS) and QA procedures for patient plan verification treated with EDWs. Modeling of EDW beams in the Pinnacle"3 TPS, which employs a collapsed-cone convolution superposition (CCCS) dose model, was based on a combination of measured open-beam data and the 'Golden Segmented Treatment Table' (GSTT) provided by Varian for each photon beam energy. To validate EDW models, dose profiles of 6 and 10 MV photon beams from a Clinac 2100 C/D were measured in virtual water at depths from near-surface to 30 cm for a wide range of field sizes and wedge angles using the Profiler 2 (Sun Nuclear Corporation, Melbourne, FL) diode array system. The EDW output factors (EDWOFs) for square fields from 4 to 20 cm wide were measured in virtual water using a ...
2009-01-21
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.
