  1. 64-row multidetector computed tomography portal venography of gastric variceal collateral circulation

    2010-01-01

    AIM:To study characteristics of collateral circulation of gastric varices (GVs) with 64-row multidetector computer tomography portal venography (MDCTPV).METHODS:64-row MDCTPV with a slice thickness of 0.625 mm and a scanning field from 2 cm above the tracheal bifurcation to the lower edge of the kidney was performed in 86 patients with GVS diagnosed by endoscopy. The computed tomography protocol included unenhanced,arterial and portal vein phases. The MDCTPV was performed on an AW4.3 workstation. GVs were c...

  2. Assessment of left ventricular ejection fraction: comparison of two dimensional echocardiography, cardiac magnetic resonance imaging and 64-row multi-detector computed tomography

    Chee Khoon LIEW; Kui Hian SIM; Rapaee ANNUAR; Tiong Kiam ONG; Sze Piaw CHIN; Tobias Seyfarth; Yean Yip FONG; Wei Ling CHAN; Choon Kiat ANG; Houng Bang LIEW

    2006-01-01

    Objectives To compare left ventricular ejection fraction (LVEF) determined from 64-row multi-detector computed tomography (64-row MDCT) with those determined from two dimensional echocardiography (2D echo) and cardiac magnetic resonance imaging (CMR). Methods Thirty-two patients with coronary artery disease underwent trans-thoracic 2D echo, CMR and contrast-enhanced 64-row MDCT for assessment of LVEF within 48 hours of each other. 64-row MDCT LVEF was derived using the Syngo Circulation software; CMR LVEF was by Area Length Ejection Fraction (ALEF) and Simpson method and 2D echo LVEF by Simpson method.Results The LVEF was 49.13 ± 15.91% by 2D echo, 50.72 ± 16.55% (ALEF method) and 47.65 ± 16.58%(Simpson method) by CMR and 50.00 ± 15.93% by 64-row MDCT. LVEF measurements by 64-row MDCT correlated well with LVEF measured with CMR using either the ALEF method (Pearson correlation r = 0.94, P <0.01) or Simpson method (r = 0.92, P<0.01). It also correlated well with LVEF measured using 2D echo (r = 0.80, P < 0.01). Conclusion LVEF measurements by 64-row MDCT correlated well with LVEF measured by CMR and 2D echo. The correlation between 64-row MDCT and CMR was better than the correlation between 2D echo with CMR. Standard data set from a 64-row MDCT coronary study can be reliably used to calculate the LVEF.

  3. 64-Row multidetector CT virtual hysterosalpingography. Findings in 2500 patients

    Objective. To depict typical features of virtual hysterosalpingography (VHSG) in infertile patients. Material and methods: 2500 VHSG performed using a 64-row MOCT were evaluated. Results: Cervical abnormalities visualized corresponded to parietal irregularities (21%); thickened folds (9%); polyps (11%); diverticula (5%); cervical strictures (8%), and synechiae (1.5%). At the level of uterine cavity, polyps (44%); submucous myomas (8%); intramural and subserosal fibroids (11%); synechiae (10%); malformations (10%); adenomyosis (4%), and cesarean section scar (3%). Unilateral hydrosalpinx (7%) and bilateral hydrosalpinx (2%). Tubal obstruction was reported in 6% of cases. The average radiation dose was 0.94 mSv. Eighty-four percent of the patients reported mild pain or no postoperative discomfort. Conclusions: The virtual hysterosalpingography allowed a proper assessment of the internal genital organs, providing useful diagnostic information on infertility and other gynecological disorders. It constitutes a virtually painless, low-dose radiation technique, besides being well tolerated by patients

  4. Collateral abdominal circulation in patient with Leriche's syndrome diagnosed with 64-row multislice computed tomography (MSCT)

    Leriche's syndrome results from slowly developing occlusion of the abdominal aorta. It affects mainly middle-aged males. The blood flow distal to the occlusion site is secured by collateral circulation. Signs of Leriche's syndrome include claudication, gluteal pain and impotence. The paper presents a patient with Leriche's syndrome, in whom a detailed visualization of collateral circulation was obtained with multislice computed tomography angiography. Patient underwent surgical recanalization of the aorta with an excellent result. To our knowledge, the presented case is the first description of collateral circulation in Leriche's syndrome obtained with 64-row computed tomography. (author)

  5. Comparison of 64-row and 16-row multidetector CT in the perfusion CT evaluation of acute ischemic stroke patients receiving intravenous thrombolytic therapy

    Sillanpaa, Niko; Dastidar, Prasun; Soimakallio, Seppo [Tampere University Hospital, Medical Imaging Centre, PL 2000, Tampere (Finland); Rusanen, Harri [Oulu University Hospital, Department of Neurology, Oulu (Finland); Saarinen, Jukka T. [Tampere University Hospital, Department of Neurology, Tampere (Finland)

    2012-09-15

    Perfusion computed tomography (PCT) is increasingly performed in multimodal CT evaluation of acute ischemic stroke. We compared the technical quality of perfusion studies performed with a 16-row and a 64-row scanner and analyzed the differences between the scanners in their ability to detect perfusion defects. We analyzed retrospectively the clinical and imaging data of 140 consecutive acute (<3 h) stroke patients who underwent multimodal CT evaluation and received intravenous rtPA. Alberta Stroke Program Early CT Score (ASPECTS) was assigned to PCT maps. Clinical and imaging parameters were compared between the two scanners. There were more motion artifacts in the 16-row studies (p = 0.04), and the analysis software was able to completely correct significantly fewer of these (p < 0.001). Both ASPECTS levels were optimally covered in only 29% of the 16-row studies, whereas in the 64-row studies, both levels were invariably optimally visualized (p < 0.001). This significantly decreased the sensitivity of the 16-row scanner to detect perfusion defects in the upper ASPECTS level (p = 0.02). The 64-row scanner was able to detect more perfusion defects that were located entirely outside the ASPECTS regions (p = 0.03). There was no significant difference in the 3-month functional outcome. The 16-row scanner suffered from limited anatomic coverage that decreased the sensitivity to detect perfusion defects in the cranial parts of the middle cerebral artery region. The 16-row studies had poorer technical quality that was in part attributable to higher sampling frequency and smaller slice thickness making the imaging more sensitive to small-scale movement of the patient. (orig.)

  6. Sensitivity and accuracy of volumetry of pulmonary nodules on low-dose 16- and 64-row multi-detector CT: an anthropomorphic phantom study

    To assess the sensitivity of detection and accuracy of volumetry by manual and semi-automated quantification of artificial pulmonary nodules in an anthropomorphic thoracic phantom on low-dose CT. Fifteen artificial spherical nodules (diameter 3, 5, 8, 10 and 12 mm; CT densities -800, -630 and +100 HU) were randomly placed inside an anthropomorphic thoracic phantom. The phantom was examined on 16- and 64-row multidetector CT with a low-dose protocol. Two independent blinded observers screened for pulmonary nodules. Nodule diameter was measured manually, and volume calculated. For solid nodules (+100 HU), diameter and volume were also evaluated by semi-automated software. Differences in observed volumes between the manual and semi-automated method were evaluated by a t-test. Sensitivity was 100 % for all nodules of >5 mm and larger, 60-80 % for solid and 0-20 % for non-solid 3-mm nodules. No false-positive nodules but high inter-observer reliability and inter-technique correlation were found. Volume was underestimated manually by 24.1 ± 14.0 % for nodules of any density, and 26.4 ± 15.5 % for solid nodules, compared with 7.6 ± 8.5 % (P 5 mm in diameter. Semi-automated volumetry yielded more accurate nodule volumes than manual measurements. (orig.)

  7. Vascular air embolism after contrast administration on 64 row multiple detector computed tomography: A prospective analysis

    Kushaljit S Sodhi

    2015-01-01

    Full Text Available Background: Vascular air embolism is being progressively reported as a nonfatal event with increase in use of computed tomography (CT as a diagnostic modality. This study was undertaken to study the frequency and site of vascular air embolism in patients undergoing contrast-enhanced CT (CECT and analyze CT parameters that influence its prevalence and final outcome. Materials and Methods: This was a prospective study approved by departmental ethics committee. Presence and location of air emboli in 200 patients who underwent CT scan of chest on a 64 detector scanner was recorded. We analyzed the role of various factors that could influence the prevalence of air embolism after injection of contrast in CECT scans. These factors included the amount of contrast injected, rate of flow of injection of contrast, site of injection of contrast, and size of intravenous access line. Results: Iatrogenic vascular air emboli were seen in 14 patients (7% of total. The locations of air emboli were main pulmonary artery in 12 (6% of total, left brachiocephalic vein in 3 (1.5% of total, right atrial appendage in 4 (2% of total, and superior vena cava (SVC in 1 (0.5% patient. There was no association between volume of contrast, flow rate, site and size of intravenous access, and presence of air emboli. Conclusion: Radiologists as well as referring physicians should be aware of vascular air embolism, which can occur after contrast injection in patients undergoing CT scan. Age, volume of contrast, flow rate of pressure injector, and site and size of venous cannula do not influence the likelihood or incidence of detection of venous air emboli on CT scans.

  8. Coronal reformations of the chest on 64-row multi-detector row CT: Evaluation of image quality in comparison with 16-, 8- and 4-row multi-detector row CT

    Purpose: To evaluate image quality of coronal reformations of chest performed on 64-row MDCT in comparison with 16-, 8- and 4-row MDCT. Materials and methods: Consecutive patients who underwent pulmonary CT angiography using four different MDCT scanners were retrospectively studied with IRB approval: (1) n = 30, 64-row MDCT; (2) n = 30, 16-row MDCT; (3) n = 30, 8-row MDCT; (4) n = 30, 4-row MDCT. Coronal reformatted images (2 mm thickness and 2 mm intervals for 64-row MDCT; 5 mm thickness and 5 mm intervals for 16-, 8- and 4-row MDCT) were evaluated by consensus reading of two board-certified radiologists who were blinded to scanner type. The image quality of overall chest appearance and individual thoracic structures including heart, aorta and pulmonary arteries was graded using five-point scale. Grades from four different scanners were compared using Kruskal-Wallis test. A second evaluation was performed in 48 randomly selected patients (12 patients for each scanner). Reproducibility was assessed using weighted-kappa analysis. Result: Significant reproducibility was observed between the first and second evaluations in 48 patients both for image quality of overall chest (weighted kappa = 0.826) and each thoracic structure (mean weighted kappa = 0.803; range, 0.729-0.858). Image quality of overall chest and individual thoracic structures differed significantly among four different MDCT groups, with 64-row MDCT having the highest grades, followed by 16-, 8- and 4-row MDCT (mean grades for overall chest in each scanner: 3.9, 3.0, 2.4 and 1.9, respectively) (P < 0.0001 for overall chest and each thoracic structure). Conclusion: When comparing coronal reformations of chest using four different MDCT scanners, the 64-row MDCT had the highest image quality for overall chest appearance and individual thoracic structures, followed by 16-, 8- and finally 4-row MDCT

  9. The added diagnostic value of 64-row multidetector CT combined with contrast-enhanced US in the evaluation of hepatocellular nodule vascularity: implications in the diagnosis of malignancy in patients with liver cirrhosis

    The aim of this study was to assess the added diagnostic value of contrast-enhanced US (CEUS) combined with 64-row multidetector CT (CT) in the assessment of hepatocellular nodule vascularity in patients with liver cirrhosis. One hundred and six cirrhotic patients (68 male, 38 female; mean age ± SD, 70 ± 7 years) with 121 biopsy-proven hepatocellular nodules (72 hepatocellular carcinomas, 10 dysplastic and 15 regenerative nodules, 12 hemangiomas, and 12 other benignancies) detected during US surveillance were prospectively recruited. Each nodule was scanned by CEUS during the arterial (10-40 s), portal venous (45-90 s), and delayed sinusoidal phase (from 100 s after microbubble injection to microbubble disappearance). Nodule vascularity at CEUS, CT, and combined CEUS/CT was evaluated side-by-side by two independent blinded readers who classified nodules as benign or malignant according to reference diagnostic criteria. The combined assessment of CEUS/CT provided higher sensitivity (97%, both readers) than did separate assessment of CEUS (88% reader 1; 87% reader 2) and CT (74% reader 1; 71% reader 2; P < 0.05), while no change in specificity was provided by combined analysis. The combined assessment of hepatocellular nodule vascularity at CT and CEUS improved sensitivity in the diagnosis of malignancy in patients with liver cirrhosis. (orig.)

  10. Interatrial shunt. Diagnosis of patent foramen ovale and atrial septal defect with 64-row coronary computed tomography angiography

    The aim of this study was to investigate the frequency with which interatrial shunts are found during routine coronary computed tomography (CT) angiography and to describe imaging characterizations of patent foramen ovale (PFO), atrial septal defect (ASD), and atrial septal aneurysm (ASA). A total of 1081 adult patients were evaluated retrospectively for interatrial shunting; 77 were excluded from the study. CT diagnosis of PFO was defined as (1) a channel-like appearance of the interatrial septum (IAS) and (2) a contrast agent jet flow from the left atrium (LA) to the right atrium (RA). ASD was defined as (1) the IAS resembling a membrane with a hole and (2) a contrast jet flow between the two atria. ASA was identified by detecting a minimum 10-mm protrusion of the LA beyond the IAS into the RA. Among 1004 patients, 86 patients (8.6%) were diagnosed to have PFO. Another 23 patients (2.3%) had a hole in the IAS and were diagnosed as having ASD: 21 with an ostium secundum-type ASD and 2 with the sinus venosus type. ASA accompanied ASD in three patients. Electrocardiography-gated CT using the saline-chaser contrast injection technique that is routinely used for coronary arterial imaging can be used to detect interatrial shunts. The technique can also serve as a method for differentiating PFO, ASD, and ASA. (author)

  11. Imaging findings of myocardial revascularization at multidetector computed tomography: where are the bypass grafts?: an iconographic essay

    Multidetector coronary computed tomography angiography is a precise method for evaluating post-coronary revascularization arterial and venous bypass grafts, and is somehow superseding coronary catheterization that is an invasive and more expensive technique. The present iconographic essay is aimed at anatomically demonstrating the bypass grafts most frequently utilized, how to differentiate between arterial and venous grafts and how to find them. The studies were performed in 64-row multidetector computed tomography equipment, with breath hold, controlled heart rate and appropriate protocols with later MPR, MIP and 3D reconstructions according to electrocardiogram. The localization of the bypass grafts and anastomoses at computed tomography studies focused on chest and coronary arteries may represent a difficulty in the images analysis by the radiologist who is not familiar with the matter, so the knowledge of the surgical techniques adopted and possible courses of the saphenous bypass grafts and arterial grafts can aid in the analysis of both studies, avoiding diagnostic errors. (author)

  12. Cardiac Computed Tomography (Multidetector CT, or MDCT)

    ... Blood Pressure Tools & Resources Stroke More Cardiac Computed Tomography (Multidetector CT, or MDCT) Updated:Sep 3,2015 What is Computerized Tomography (CT)? CT is a noninvasive test that uses ...

  13. Correlation of 64 row MDCT, echocardiography and cardiac catheterization angiography in assessment of pulmonary arterial anatomy in children with cyanotic congenital heart disease

    Chandrashekhar, Guruprasadh, E-mail: cguruprasadh@gmail.com [Departments of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Sector-12, Chandigarh 160012 (India); Sodhi, Kushaljit Singh, E-mail: sodhiks@gmail.com [Departments of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Sector-12, Chandigarh 160012 (India); Saxena, Akshay Kumar, E-mail: fatakshay@yahoo.com [Departments of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Sector-12, Chandigarh 160012 (India); Rohit, Manoj Kumar, E-mail: rohitmanoj@gmail.com [Department of Pediatric Cardiology, Post Graduate Institute of Medical Education and Research, Sector-12, Chandigarh 160012 (India); Khandelwal, Niranjan, E-mail: khandelwaln@hotmail.com [Departments of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Sector-12, Chandigarh 160012 (India)

    2012-12-15

    Objective: To study the correlation of low-dose 64-row multi-detector computed tomography (MDCT) with echocardiography and cardiac catheterization angiography (CCA) in the assessment of pulmonary arterial anatomy in children with cyanotic congenital heart disease (CCHD). Materials and methods: This prospective study included 105 children (74 males, 31 females) with CCHD, in the age group of 2 months to 20 years, who underwent 64-row MDCT examination (low-dose CT protocol), echocardiography and CCA for the assessment of pulmonary arteries, including visualization, presence of confluence, stenosis and collaterals. Statistical analysis was performed using the non-parametric statistical analysis test to evaluate the concordance or discordance between echocardiography, MDCT and CCA. Results: 64-row MDCT detected significantly more main and branch pulmonary arteries, patent pulmonary confluences, and more cases of pulmonary artery stenosis. CCA detected more major aorto-pulmonary collaterals than MDCT, whereas echocardiography failed to identify these major aorto-pulmonary collaterals. The effective CT radiation dose to patients less than 2 years of age was in the range of 0.7–2.5 mSv, where as the dose in patients more than 2 years of age ranged from that of 2.1 to 4.2 mSv, which is much less than the radiation dose reported in cardiac catheterization angiography. Conclusion: In cases where cardiac MRI cannot be performed, or is not sufficiently informative, low-dose 64-row MDCT correlates well with CCA and can provide adequate information about pulmonary arterial anatomy in children with cyanotic congenital heart disease, and can replace invasive cardiac catheterization angiography with markedly reduced radiation dosage to the patient.

  14. Correlation of 64 row MDCT, echocardiography and cardiac catheterization angiography in assessment of pulmonary arterial anatomy in children with cyanotic congenital heart disease

    Objective: To study the correlation of low-dose 64-row multi-detector computed tomography (MDCT) with echocardiography and cardiac catheterization angiography (CCA) in the assessment of pulmonary arterial anatomy in children with cyanotic congenital heart disease (CCHD). Materials and methods: This prospective study included 105 children (74 males, 31 females) with CCHD, in the age group of 2 months to 20 years, who underwent 64-row MDCT examination (low-dose CT protocol), echocardiography and CCA for the assessment of pulmonary arteries, including visualization, presence of confluence, stenosis and collaterals. Statistical analysis was performed using the non-parametric statistical analysis test to evaluate the concordance or discordance between echocardiography, MDCT and CCA. Results: 64-row MDCT detected significantly more main and branch pulmonary arteries, patent pulmonary confluences, and more cases of pulmonary artery stenosis. CCA detected more major aorto-pulmonary collaterals than MDCT, whereas echocardiography failed to identify these major aorto-pulmonary collaterals. The effective CT radiation dose to patients less than 2 years of age was in the range of 0.7–2.5 mSv, where as the dose in patients more than 2 years of age ranged from that of 2.1 to 4.2 mSv, which is much less than the radiation dose reported in cardiac catheterization angiography. Conclusion: In cases where cardiac MRI cannot be performed, or is not sufficiently informative, low-dose 64-row MDCT correlates well with CCA and can provide adequate information about pulmonary arterial anatomy in children with cyanotic congenital heart disease, and can replace invasive cardiac catheterization angiography with markedly reduced radiation dosage to the patient.

  15. Prevalence and Characteristics of Myocardial Bridging in Multidetector-Row Computed Tomography Coronary Angiography

    Background: Myocardial bridging (MB) are congenital defects of the coronary arteries in which a segment of an epicardial artery lies in the myocardium for part of its course. The current gold standard for diagnosing MB is coronary angiography; however other invasive techniques are also useful. Myocardial bridging can also be visualized with the use of novel non-invasive imaging techniques such as multidetector-row computed tomography coronary angiography (MDCT-CA). Objectives: To assess the prevalence and characteristics of myocardial bridging in patients undergoing multidetector-row computed tomography coronary angiography (MDCT-CA). Material and Methods: A total of 452 consecutive patients were evaluated with 16-row and 64-row MDCT-CA due to the presence of abnormal findings in myocardial perfusion image tests, symptoms suggestive of coronary artery disease, and in asymptomatic patients with a family history of coronary artery disease. The presence of MB, their location and characteristics were analyzed. Myocardial bridging were classified as complete and incomplete bridges with respect to continuity of the myocardium over the tunneled segment of the artery involved. Quantitative measurements of vessel diameter during systole and diastole were evaluated. Results: The prevalence of MB was 35.18%; 88 were complete and 71 incomplete. Among complete MB, 6 affected both systole and diastole, 27 presented only systolic compression and 55 showed no compression. Incomplete MB showed absence of arterial compression. Conclusions: Multidetector-row computed tomography coronary angiography detected a higher prevalence of MB in the study population and allowed to classify them and to assess their functional aspects throughout the cardiac cycle. (authors)

  16. HORSESHOE KIDNEY: A MULTIDETECTOR COMPUTED TOMOGRAPHY STUDY

    Sharma V

    2015-06-01

    Full Text Available Background and Objective: Horseshoe kidney is the most common renal fusion anomaly with a reported prevalence of 1 in 400 persons with a male to female ratio of 2:1. In many cases its presence may go unnoticed and undiagnosed because the patient may remain asymptomatic throughout life. The objective of our study is to report radiological and anatomical features of horseshoe kidney detected incidentally during retrospective evaluation of multidetector computed tomography scans. Materials and Methods: Contrast enhanced multidetector computed tomography scans of 682 patients, 355 males and 327 females, were reviewed retrospectively. Results: Seven cases of horseshoe kidney were detected incidentally, six males and one female, with an incidence of 1.02 %. In all cases, malrotation of the kidneys were observed with the hilum facing anteriorly or anterolaterally. The isthmus was made up of parenchymal tissue in all the cases and the fusion was midline in four cases and lateral in three cases. Horseshoe kidney in all cases was supplied by multiple renal arteries, varying from 3 to 6. In three cases symmetrical arterial supply and in the rest asymmetrical supply was observed. Nephrolithiasis and hydronephrosis were noted in two patients. No other associated congenital anomaly was observed in all seven patients. Conclusion: Contrast enhanced multidetector computed tomography evaluation of patients with horseshoe kidney provide excellent information about its vascularity, collecting system and other associated conditions.

  17. Multidetector computed tomography virtual hysterosalpingography in the investigation of the uterus and fallopian tubes

    Carrascosa, Patricia [Diagnostico Maipu, Av. Maipu 1668, Vicente Lopez B1602ABQ, Buenos Aires (Argentina)], E-mail: patriciacarrascosa@diagnosticomaipu.com.ar; Baronio, Mariano [CEGYR, Viamonte 1438, Capital Federal C1055ABB (Argentina); Capunay, Carlos; Lopez, Elba Martin; Vallejos, Javier [Diagnostico Maipu, Av. Maipu 1668, Vicente Lopez B1602ABQ, Buenos Aires (Argentina); Borghi, Mario; Sueldo, Carlos; Papier, Sergio [CEGYR, Viamonte 1438, Capital Federal C1055ABB (Argentina)

    2008-09-15

    Objective: To compare the efficacy of multidetector CT virtual hysterosalpingography (MDCT-VH) with conventional X-ray hysterosalpingography (HSG) in the evaluation of patients with diagnosis of infertility. Methods: Sixty patients with diagnosis of infertility scheduled to perform a HSG, were evaluated with 16-row (n = 50) and 64-row (n = 10) MDCT-VH. In 35 patients the examination was performed without a tenaculum. The HSGs were carried out using standard technique. The HSG and MDCT-VH findings were compared. The duration for both examinations and patient discomfort were documented. The sensitivity and specificity of MDCT-VH for the detection of uterine pathology and tubal obstruction were calculated using the exact binomial method. Agreement between the two methods was assessed by the Cohen's kappa method (k). Results: The mean duration for MDCT-VH (16 and 64-rows) was 5 {+-} 3 min, whereas for HSG was 28 {+-} 3. The MDCT-VH without a tenaculum was the procedure with less patient discomfort. Sensitivity, specificity and inter-method agreement for the detection of uterine pathology were 100%, 92% and k = 0.92 for 16-row MDCT-VH and 100%, 100% and k = 1 for 64-row MDCT-VH, respectively. Sensitivity and specificity for detection of tubal obstruction were 80% and 80% for 16-row MDCT-VH and 100% and 100% for 64-row MDCT-VH, respectively; inter-method agreement for the visualization of the tubes was k = 0.54 for 16-row MDCT-VH and k = 1 for 64-row MDCT-VH. Conclusion: This study demonstrated the feasibility of evaluating the female reproductive system by MDCT-VH. 64-Row MDCT-VH could be an alternative diagnostic technique in the infertility workup algorithm. A larger study is in progress to validate these encouraging results.

  18. Multidetector computed tomography angiography of the abdomen

    Multidetector computed tomography (MDCT) angiography has provided excellent opportunities for advancement of computed tomography (CT) technology and clinical applications. It has a wide range of applications in the abdomen including vascular pathologies either occlusive or aneurysmal; enables the radiologist to produce vascular mapping that clearly show tumor invasion of vasculature and the relationship of vessels to mass lesions. MDCTA can be used in preoperative planning for hepatic resection, preoperative evaluation and planning for liver transplantation. MDCTA can also provide extremely valuable information in the evaluation of ischemic bowel disease, active Crohn disease, the extent and location of collateral vessels in cirrhosis

  19. Multidetector Computed Tomography in Acute Joint Fractures

    Haapamaeki, V.V.; Kiuru, M.J.; Mustonen, A.O.; Koskinen, S.K. [Helsinki Univ. Central Hospital (Finland). Helsinki Medical Imaging Center

    2005-10-01

    Conventional radiography plays an essential diagnostic role in the primary evaluation of acute joint trauma. In complex fractures, however, computed tomography (CT) is an imaging modality often used second to radiography. As a result of technical breakthroughs in the field, multidetector CT (MDCT) allows faster imaging and better temporal, spatial, and contrast resolution compared with conventional single-slice spiral CT. MDCT with multiplanar reformation is helpful in disclosing fracture patterns, particularly in complex joint fractures, where they reveal occult fractures and show the exact number of fracture components and their degree of displacement.

  20. Multidetector Computed Tomography in Acute Joint Fractures

    Conventional radiography plays an essential diagnostic role in the primary evaluation of acute joint trauma. In complex fractures, however, computed tomography (CT) is an imaging modality often used second to radiography. As a result of technical breakthroughs in the field, multidetector CT (MDCT) allows faster imaging and better temporal, spatial, and contrast resolution compared with conventional single-slice spiral CT. MDCT with multiplanar reformation is helpful in disclosing fracture patterns, particularly in complex joint fractures, where they reveal occult fractures and show the exact number of fracture components and their degree of displacement

  1. ECG-Edit function in multidetector-row computed tomography coronary arteriography for patients with arrhythmias

    Electrocardiogram (ECG)-gating is necessary for cardiac computed tomography, but is not suitable for arrhythmias, so the aim of this study was to evaluate the usefulness of the ECG-edit function for this purpose. Of 1,221 patients undergoing 64-row multidetector-row computed tomography coronary angiography (coronary MDCT), 123 patients (28 atrial fibrillation (Af), 39 premature atrial contractions (PAC), 42 premature ventricular contractions (PVC), 3 PAC+PVC, 10 sinus arrhythmias (SA), and a second-degree atrioventricular block (2deg AVB)) had arrhythmias necessitating the ECG-edit function. Short R-R interval was deleted and mid-diastolic phases were selected from the long R-R intervals using the ''R+absolute time'' method. In the present study, the reconstructed images were evaluated using a triple-grade scale A-C, representing excellent, acceptable, and unacceptable image quality. Image quality, categorized as A, B and C, respectively, was 50%, 36% and 14% for the 28 patients with Af; 56%, 36% and 8% for the 39 PAC patients, and 65%, 33% and 2% in the 42 PVC patients. None of the scans of the PAC+PVC, SA, and 2deg AVB patients was ranked as C. The ECG-edit function is useful for reconstructing coronary MDCT images in many arrhythmias, and provides clinically acceptable images in most cases. (author)

  2. Myocardial perfusion with multi-detector computed tomography: quantitative evaluation

    The objective of this work is to evaluate the skill of multidetector computer tomography, to quantify the different patterns of intensification during the evaluation of the myocardial perfusion. 45 patients were studied with suspicion of cardiovascular disease. Multi-detector computed tomography was utilized on patients at rest and in effort with pharmacological stress, after the administration of dipyridamole. Also they were evaluated using nuclear medicine

  3. Detection of Postcoronary Stent Complication: Utility of 64-Slice Multidetector CT

    Alpa Bharati

    2012-01-01

    Full Text Available Coronary stent fracture is a known complication of coronary arterial stent placements. Multiple long-term risks are also associated with drug eluting stents. 64-slice multidetector CT (MDCT coronary angiography has been shown to detect poststent complications such as instent stenosis, thrombosis, stent migration and stent fractures. We report a case of stent fracture in a patient who underwent RCA stenting with associated RCA perforation and almost complete thrombosis of the RCA and peristent fibrinoid collection. This is a rare case of stent fracture with perforation of the RCA. The paper highlights the role of 64-row multidetector computed tomography (MDCT in evaluation of such poststent placement complications.

  4. [Valvular heart disease: multidetector computed tomography evaluation].

    Franco, A; Fernández-Pérez, G C; Tomás-Mallebrera, M; Badillo-Portugal, S; Orejas, M

    2014-01-01

    Heart valve disease is a clinical problem that has been studied with classical imaging techniques like echocardiography and MRI. Technological advances in CT make it possible to obtain static and dynamic images that enable not only a morphological but also a functional analysis in many cases. Although it is currently indicated only in patients with inconclusive findings at echocardiography and MRI or those in whom these techniques are contraindicated, multidetector CT makes it possible to diagnose stenosis or regurgitation through planimetry, to evaluate and quantify valvular calcium, and to show the functional repercussions of these phenomena on the rest of the structures of the heart. Given that multidetector CT is being increasingly used in the diagnosis of ischemic heart disease, we think it is interesting for radiologists to know its potential for the study of valvular disease. PMID:23246401

  5. Multidetector computed tomography of jaw lesions in children and adolescents

    Full text: Jaw lesions in paediatric and adolescent population are uncommon and can arise in odontogenic or non-odontogenic tissues. With the advent of multidetector computed tomography (MDCT), algorithm for imaging jaw lesions has changed dramatically. This pictorial essay describes the imaging appearance of commonly encountered jaw lesions in children and adolescents with emphasis on MDCT findings

  6. Tracheo-oesophageal fistula diagnosed with multidetector computed tomography.

    Hodnett, Pa

    2009-04-01

    This case highlights important issues in investigation of patients with suspected tracheo-oesophageal fistula including the value of multidetector computed tomography, the importance of thorough imaging evaluation when high clinical suspicion of tracheo-oesophageal fistula exists and the value of close interaction between radiologists and intensive care physicians in the investigation of these patients.

  7. Noninvasive coronary angioscopy using electron beam computed tomography and multidetector computed tomography

    van Ooijen, PMA; Nieman, K; de Feyter, PJ; Oudkerk, M

    2002-01-01

    With the advent of noninvasive coronary imaging techniques like multidetector computed tomography and electron beam computed tomography, new representation methods such as intracoronary visualization. have been introduced. We explore the possibilities of these novel visualization techniques and comp

  8. Multidetector computed tomography of the coronary arteries - pictorial essay

    Multidetector computed tomography (MDCT) is being used more frequently for the detection of atherosclerotic coronary artery disease (CAD). MDCT allows for very rapid image acquisition with little motion artifact, resulting in the ability to quantitate calcified atherosclerotic plaque. Congenital coronary artery anomalies are readily identified using this technique. A key advantage is the noninvasiveness of the study, with no intravascular contrast media needed. Knowledge of coronary artery anatomy as well as of the potential pitfalls is required. (author)

  9. Multidetector computed tomography in the preoperative staging of gastric adenocarcinoma

    Barros, Ricardo Hoelz de Oliveira; Penachim, Thiago Jose; Martins, Daniel Lahan; Andreollo, Nelson Adami; Caserta, Nelson Marcio Gomes, E-mail: rhobarros@hotmail.com [Universidade Estadual de Campinas (UNICAMP), Campinas, SP (Brazil)

    2015-03-15

    Objective: To evaluate the role of multidetector computed tomography in the preoperative investigation of tumor invasion depth and lymph node and metastatic involvement according to the TNM classification, in patients with gastric adenocarcinoma. Materials and Methods: Fifty-four patients with biopsy-confirmed gastric cancer underwent preoperative staging with 64-channel multidetector computed tomography. Two independent radiologists analyzed the images and classified the findings. Sensitivity, specificity, accuracy and overall accuracy were calculated for each observer. The interobserver agreement was also evaluated. Results: The accuracy in the classification of categories T ranged from 74% to 96% for observer 1 and from 80% to 92% for observer 2. The overall accuracy was 70% for both observers. The weighted kappa index was 0.75, consistent with a significant interobserver agreement. The accuracy in the classification of lymph node involvement (category N) ranged from 55% to 79% for observer 1 and from 73% to 82% for observer 2. The evaluation of metastatic involvement showed an overall accuracy of 89.6% for both observers. Conclusion: 64-channel multidetector computed tomography demonstrated clinically relevant accuracy in the preoperative staging of gastric adenocarcinoma as regards invasion depth (T category) and metastatic involvement (M category). (author)

  10. Integral diagnosis of coronary atherosclerosis by coronary multidetector computed tomography and by invasive coronary angiography

    Coronary angiography by multidetector computed tomography (CMDCT) visualizes the wall and lumen of coronary arteries. Invasive coronary angiography (INVCA) only visualizes the arterial lumen but with better resolution

  11. Multidetector-row computed tomography of thoracic aortic anomalies in dogs and cats: Patent ductus arteriosus and vascular rings

    Nolte Ingo

    2011-09-01

    Full Text Available Abstract Background Diagnosis of extracardiac intrathoracic vascular anomalies is of clinical importance, but remains challenging. Traditional imaging modalities, such as radiography, echocardiography, and angiography, are inherently limited by the difficulties of a 2-dimensional approach to a 3-dimensional object. We postulated that accurate characterization of malformations of the aorta would benefit from 3-dimensional assessment. Therefore, multidetector-row computed tomography (MDCT was chosen as a 3-dimensional, new, and noninvasive imaging technique. The purpose of this study was to evaluate patients with 2 common diseases of the intrathoracic aorta, either patent ductus arteriosus or vascular ring anomaly, by contrast-enhanced 64-row computed tomography. Results Electrocardiography (ECG-gated and thoracic nongated MDCT images were reviewed in identified cases of either a patent ductus arteriosus or vascular ring anomaly. Ductal size and morphology were determined in 6 dogs that underwent ECG-gated MDCT. Vascular ring anomalies were characterized in 7 dogs and 3 cats by ECG-gated MDCT or by a nongated thoracic standard protocol. Cardiac ECG-gated MDCT clearly displayed the morphology, length, and caliber of the patent ductus arteriosus in 6 affected dogs. Persistent right aortic arch was identified in 10 animals, 8 of which showed a coexisting aberrant left subclavian artery. A mild dilation of the proximal portion of the aberrant subclavian artery near its origin of the aorta was present in 4 dogs, and a diverticulum analogous to the human Kommerell's diverticulum was present in 2 cats. Conclusions Contrast-enhanced MDCT imaging of thoracic anomalies gives valuable information about the exact aortic arch configuration. Furthermore, MDCT was able to characterize the vascular branching patterns in dogs and cats with a persistent right aortic arch and the morphology and size of the patent ductus arteriosus in affected dogs. This additional

  12. Tumor volume of resectable gastric adenocarcinoma on multidetector computed tomography: association with N categories

    Li, Hang; Chen, Xiao-Li; Li, Jun-ru; Li, Zhen-lin; Chen, Tian-wu; Pu, Hong; Yin, Long-Lin; XU, GUO-HUI; Li, Zhen-wen; Reng, Jing; Zhou, Peng; Cheng, Zhu-zhong; Cao, Ying

    2016-01-01

    OBJECTIVE: To determine whether the gross tumor volume of resectable gastric adenocarcinoma on multidetector computed tomography could predict the presence of regional lymph node metastasis and could determine N categories. MATERIALS AND METHODS: A total of 202 consecutive patients with gastric adenocarcinoma who had undergone gastrectomy 1 week after contrast-enhanced multidetector computed tomography were retrospectively identified. The gross tumor volume was evaluated on multidetector comp...

  13. Tumor volume of resectable gastric adenocarcinoma on multidetector computed tomography: association with N categories

    Hang Li; Xiao-li Chen; Jun-ru Li; Zhen-lin Li; Tian-wu Chen; Hong Pu; Long-lin Yin; Guo-hui Xu; Zhen-wen Li; Jing Reng; Peng Zhou; Zhu-zhong Cheng; Ying Cao

    2016-01-01

    OBJECTIVE: To determine whether the gross tumor volume of resectable gastric adenocarcinoma on multidetector computed tomography could predict the presence of regional lymph node metastasis and could determine N categories. MATERIALS AND METHODS: A total of 202 consecutive patients with gastric adenocarcinoma who had undergone gastrectomy 1 week after contrast-enhanced multidetector computed tomography were retrospectively identified. The gross tumor volume was evaluated on multidetector com...

  14. Total body height estimation using sacrum height in Anatolian Caucasians: multidetector computed tomography-based virtual anthropometry

    Karakas, Hakki Muammer [Inonu University Medical Faculty, Turgut Ozal Medical Center, Department of Radiology, Malatya (Turkey); Celbis, Osman [Inonu University Medical Faculty Turgut Ozal Medical Center, Department of Forensic Medicine, Malatya (Turkey); Harma, Ahmet [Inonu University Medical Faculty Turgut Ozal Medical Center, Department of Orthopaedics and Traumatology, Malatya (Turkey); Alicioglu, Banu [Trakya University Medical Faculty, Department of Radiology, Edirne (Turkey); Trakya University Health Sciences Institute, Department of Anatomy, Edirne (Turkey)

    2011-05-15

    Estimation of total body height is a major step when a subject has to be identified from his/her skeletal structures. In the presence of decomposed skeletons and missing bones, estimation is usually based on regression equation for intact long bones. If these bones are fragmented or missing, alternative structures must be used. In this study, the value of sacrum height (SH) in total body height (TBH) estimation was investigated in a contemporary population of adult Anatolian Caucasians. Sixty-six men (41.6 {+-} 14.9 years) and 43 women (41.1 {+-} 14.2 years) were scanned with 64-row multidetector computed tomography (MDCT) to obtain high-resolution anthropometric data. SH of midsagittal sections was electronically measured. The technique and methodology were validated on a standard skeletal model. Sacrum height was 111.2 {+-} 12.6 mm (77-138 mm) in men and 104.7 {+-} 8.2 (89-125 mm) in women. The difference between the two sexes regarding SH was significant (p < 0.0001). SH did not significantly correlate with age in men, whereas the correlation was significant in women (p < 0.03). The correlation between SH and the stature was significant in men (r = 0.427, p < 0.0001) and was insignificant in women. For men the regression equation was [Stature = (0.306 x SH)+137.9] (r = 0.54, SEE = 56.9, p < 0.0001). Sacrum height is not susceptible to sex, or to age in men. In the presence of incomplete male skeletons, SH helps to determine the stature. This study is also one of the initial applications of MDCT in virtual anthropometric research. (orig.)

  15. Multidetector Computer Tomography: Evaluation of Blunt Chest Trauma in Adults

    João Palas

    2014-01-01

    Full Text Available Imaging plays an essential part of chest trauma care. By definition, the employed imaging technique in the emergency setting should reach the correct diagnosis as fast as possible. In severe chest blunt trauma, multidetector computer tomography (MDCT has become part of the initial workup, mainly due to its high sensitivity and diagnostic accuracy of the technique for the detection and characterization of thoracic injuries and also due to its wide availability in tertiary care centers. The aim of this paper is to review and illustrate a spectrum of characteristic MDCT findings of blunt traumatic injuries of the chest including the lungs, mediastinum, pleural space, and chest wall.

  16. Multidetector Computer Tomography: Evaluation of Blunt Chest Trauma in Adults

    Imaging plays an essential part of chest trauma care. By definition, the employed imaging technique in the emergency setting should reach the correct diagnosis as fast as possible. In severe chest blunt trauma, multidetector computer tomography (MDCT) has become part of the initial workup, mainly due to its high sensitivity and diagnostic accuracy of the technique for the detection and characterization of thoracic injuries and also due to its wide availability in tertiary care centers. The aim of this paper is to review and illustrate a spectrum of characteristic MDCT findings of blunt traumatic injuries of the chest including the lungs, mediastinum, pleural space, and chest wall.

  17. [Multidetector computed tomography of urolithiasis: technique and results].

    Karul, M; Heuer, R; Regier, M

    2013-02-01

    The diagnosis of acute urolithiasis results from unenhanced multidetector computed tomography (MDCT). This test analyses the functional and anatomical possibility for passing an ureteral calculi, the localization and dimension of which are important parameters for further therapy. Alternatively chronic urolithiasis could be ruled out by magnetic resonance urography (MRU). MRU is the first choice especially in pregnant women and children because of radiation hygiene. Enhanced MDCT must be emphasized as an alternative to intravenous urography (IVU) for diagnosis of complex drainage of urine and suspected disorder of the involved kidney. This review illustrates the principles of different tests and the clinical relevance thereof. PMID:23129460

  18. Multidetector computed tomography of urolithiasis. Technique and results

    The diagnosis of acute urolithiasis results from unenhanced multidetector computed tomography (MDCT). This test analyses the functional and anatomical possibility for passing an ureteral calculi, the localization and dimension of which are important parameters for further therapy. Alternatively chronic urolithiasis could be ruled out by magnetic resonance urography (MRU). MRU is the first choice especially in pregnant women and children because of radiation hygiene. Enhanced MDCT must be emphasized as an alternative to intravenous urography (IVU) for diagnosis of complex drainage of urine and suspected disorder of the involved kidney. This review illustrates the principles of different tests and the clinical relevance thereof. (orig.)

  19. CROSSED RENAL ECTOPIA WITHOUT FUSION: A MULTIDETECTOR COMPUTED TOMOGRAPHY STUDY

    C.S Ramesh Babu

    2015-12-01

    Full Text Available Background: Congenital positional, rotational and fusion anomalies of the kidney are frequently encountered. Crossed renal ectopia is a condition in which the kidney is located on the side contralateral to its ureteral insertion into the urinary bladder. Crossed renal ectopia without fusion is a very rare anomaly sporadically reported in the literature. We have attempted to analyse such renal anomalies in a large series of patients. Materials & Methods: Contrast enhanced multidetector computed tomographic scans of 960 patients (491 males and 469 females, age range 4-90 years were reviewed . Observations: Crossed renal ectopia without fusion was detected in three patients (0.31%; 1 in 320 cases. All three patients were males and left- to-right renal ectopia was noted in two cases and right-to-left ectopia in one case, in whom the ectopic right kidney was exhibiting multicystic dysplasia. An interesting observation was vascularisation of crossed ectopic unfused left kidneys by branches arising from the right common iliac artery. Conclusion: Crossed renal ectopia without fusion is an extremely rare anomaly and may remain asymptomatic without being detected. Multidetector computed tomography angiography is an excellent imaging modality to detect renal positional and rotational anomalies. To the best of our knowledge the present study is the first study to detect renal anomalies in a large series of cases.

  20. Pulmonary involvement in ankylosing spondylitis assessed by multidetector computed tomography

    Ankylosing spondylitis (AS) may present with extra-articular involvement in the lungs. We aimed to evaluate the abnormal pulmonary multidetector computed tomography findings of patients with AS and compare them with the clinical symptoms, duration of illness, laboratory results and pulmonary function tests (PFT). We evaluated the chest multidetector computed tomography (MDCT) findings of 41 patients with ankylosing spondylitis (AS) and compared them with pulmonary function test (PFT) results, demographic characteristics, duration of illness and laboratory findings that we were able to obtain. The most common abnormalities were nodules, peribronchial thickening, pleural thickening and bronchiectasis. Abnormalities occurred in 96.87% of patients in the early AS group and 77.8% of patients in the late AS group. Patients with early AS included asymptomatic individuals with normal PFT results and abnormal MDCT findings. The use of MDCT in AS patients may be beneficial for the evaluation of pulmonary disease, even in asymptomatic patients without any PFT abnormalities and those in the early stages of the disease

  1. CROSSED FUSED RENAL ECTOPIA MULTIDETECTOR COMPUTED TOMOGRAPHY STUDY

    Sharma V

    2014-06-01

    Full Text Available Crossed renal ectopia is one of the rarest congenital malformations where a kidney is located on the side opposite to the side of its ureteral insertion into the urinary bladder and is generally fused with the normally located ipsilateral mate. Generally this anomaly remains as a silent clinical entity and is incidentally detected during evaluation for other conditions. We report here three such cases of crossed fused renal ectopia detected by multidetector row contrast enhanced computed tomography. Crossed fused renal ectopia of inferior type was observed in a male on the right side with the ureter of the ectopic left kidney crossing the midline. In two female patients, L-shaped or tandem kidney was noted, one on the right and another on the left side. Over all in two cases the left kidney was ectopic and in one the right kidney. No renal pathologies like urinary tract infection, nephrolithiasis or hematuria were found in our patients.

  2. Acute mediastinitis: multidetector computed tomography findings following cardiac surgery

    Macedo, Clarissa Aguiar de [Universidade de Sao Paulo (USP), SP (Brazil). Faculdade de Medicina. Instituto do Coracao (InCor)]. E-mail: clarissaaguiarm@yahoo.com.br; Baena, Marcos Eduardo da Silva [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Ultrasonography; Uezumi, Kiyomi Kato [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Computed Tomography; Castro, Claudio Campi de [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Magnetic Resonance Imaging; Lucarelli, Claudio Luiz [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Center of Diagnosis; Cerri, Giovanni Guido [Universidade de Sao Paulo (USP), SP (Brazil). School of Medicine. Dept. of Radiology

    2008-07-15

    Postoperative mediastinitis is defined as an infection of the organs and tissues in the mediastinal space, with an incidence ranging between 0.4% and 5% of cases. This disease severity varies from infection of superficial tissues in the chest wall to fulminant mediastinitis with sternal involvement. Diagnostic criterion for postoperative detection of acute mediastinitis at computed tomography is the presence of fluid collections and gas in the mediastinal space, which might or might not be associated with peristernal abnormalities such as edema of soft tissues, separation of sternal segments with marginal bone resorption, sclerosis and osteomyelitis. Other associated findings include lymphadenomegaly, pulmonary consolidation and pleural/ pericardial effusion. Some of these findings, such as mediastinal gas and small fluid collections can be typically found in the absence of infection, early in the period following thoracic surgery where the effectiveness of computed tomography is limited. After approximately two weeks, computed tomography achieves almost 100% sensitivity and specificity. Patients with clinical suspicion of mediastinitis should be submitted to computed tomography for investigating the presence of fluid collections to identify the extent and nature of the disease. Multidetector computed tomography allows 3D images reconstruction, contributing particularly to the evaluation of the sternum. (author)

  3. Evaluation of donor kidney using multidetector spiral computed tomography

    Full text: Multidetector spiral computed tomography (CT) is now replacing traditional angiography and intravenous pyelography (IVP) in assessing potential renal donors. The accuracy of this modality is assessed by comparison with the gold standard of surgery. A prospective study was performed. Fifteen renal donors were assessed using multidetector spiral CT between September 1999 and July 2001. Siemens-Volume Zoom and GE Lightspeed CT scanners were used. The patients subsequently underwent donor surgery and the findings at surgery were compared to that of the CT findings. The CT protocol involved pre-contrast images of the kidneys to detect calculi using 2.5mm collimation with 5 x 5mm axial reconstructions. Subsequently, an arterial phase was obtained through the kidneys to the mid pelvis with bolus tracking to optimise the timing of the contrast. Non-ionic contrast (Visipaque 270, Isovue 300, Iomeron 300) was administered at 5ml/s using a total of 150ml. Collimation of 1mm was used in obtaining images during the arterial phase, with 3 x 3mm reconstructions for printing of axial images. Axial reconstructions at 1 x 1.25mm were also performed for assessment on the workstations and for post-processing (Maximal Intensity Projection - MIP and Surface Shaded Display - SSD). A venous phase was then acquired through the kidneys using a collimation of 2.5mm, starting at 60 seconds after the initial administration of intravenous contrast. Axial reconstructions at 5 x 5mm were obtained for printing of these images. Axial reconstructions at 1.5mm x 3mm were obtained for workstation viewing plane and for postprocessing (Multiplanar Reformation - MPR) in the assessment of the renal veins. Two minutes following intravenous injection a topogram was performed to demonstrate the pelvicalyceal systems and ureters. A small field of view was used throughout, centered on the kidneys. Before the manipulation and processing of the 3D images, the axial images were assessed for the number

  4. Rectal cancer staging: Multidetector-row computed tomography diagnostic accuracy in assessment of mesorectal fascia invasion

    Ippolito, Davide; Drago, Silvia Girolama; Franzesi, Cammillo Talei; Fior, Davide; Sironi, Sandro

    2016-01-01

    AIM: To assess the diagnostic accuracy of multidetector-row computed tomography (MDCT) as compared with conventional magnetic resonance imaging (MRI), in identifying mesorectal fascia (MRF) invasion in rectal cancer patients.

  5. Multidetector computed tomography in acute lower gastrointestinal bleeding

    John Palma

    2010-11-01

    Full Text Available John Palma, Marius Mihaila, Frank PilleulDépartement de Radiologie Digestive et des Urgences, Hôpital Edouard Herriot, Hospices Civils de Lyon, CHU, Lyon, FranceBackground: The aim of this study is to evaluate multidetector computed tomography (MDCT in acute massive lower gastrointestinal bleeding, with endoscopy and surgery as reference examinations.Methods: A single-center retrospective study involving 34 patients with acute massive lower gastrointestinal bleeding was carried out. All patients were evaluated by MDCT scan then endoscopic or surgical examinations. Sensitivity, specificity, and positive and negative predictive values of MDCT scan were calculated using the extravasation of the contrast agent as the main criterion.Results: Extravasation of the contrast agent was found in 30 of 34 patients (88%. The bleeding site seen on CT was always the same as on endoscopic or surgical examinations (100%. Sensitivity of MDCT scan was 94%, specificity 100%, positive predictive value 100%, and negative predictive value 50% (P < 0.001. Twelve diverticulum bleedings were seen on MDCT scan compared with 13 (92% on endoscopic or surgical examinations. Angiodysplasia was overestimated by MDCT scan.Conclusion: MDCT scan appears to be an excellent tool to find and localize the bleeding site in cases of acute massive lower gastrointestinal disease.Keywords: MDCT, acute lower gastrointestinal bleeding, extravasation, contrast agent

  6. Evaluation of myocardial bridge with multidetector computed tomography

    The myocardial bridge (MB) is an intramural segment of coronary artery that is covered with myocardial tissue. The current diagnostic methods are coronary angiography, intravascular ultrasound and intracoronary Doppler, which are all invasive modalities. In this study, multidetector computed tomography (MDCT) was used to detect and evaluate the anatomical properties of the MB. The 607 patients with suspected or known coronary artery disease underwent 64-slice MDCT. MB was diagnosed when an intramural segment of coronary artery was visualized on axial and multiplanar reconstruction images. The prevalence, length, myocardial thickness, and location were evaluated. Of the 607 patients, 39 (6.42%) had a MB. In 20 patients (52.6%), the MB was located in the mid left anterior descending artery. The length of tunneled artery was a mean 16.3 mm, from 6.9 mm to 30 mm, and the maximum thickness of the myocardial tissue was between 0.5 mm and 3.9 mm, with a mean of 1.8 mm. The length of the MB correlated significantly with thickness (P=0.049). The incidence of MB and its anatomical properties can be evaluated with MDCT, which might be a useful and noninvasive method of detecting this variant. (author)

  7. Multidetector computed tomography diagnosis of adult elbow fractures

    Haapamaki, V.V.; Kiuru, M.J.; Koskinen, S.K. [Helsinki Univ. Central Hospital, Toolo (Finland). Dept. of Radiology

    2004-02-01

    To assess acute phase multidetector computed tomography (MDCT) findings in elbow traumas. Fifty-six patients (32 M, 24 F, age 16 to 88 years, mean 44 years) underwent MDCT of the elbow due to an acute trauma during a time period of 34 months. A total of 65 fractures and 3 main fracture types were established: 16 (25%) ulnar coronoid process fractures, 13 (20%) radial head fractures, and 12 (18%) humeral supracondylar fractures. Three main injury mechanisms were falling (38 (68%) patients), falling from high places (6 (11%) patients), and traffic accidents (5 (9%) patients). In 6 (11%) patients, MDCT revealed 13 occult fractures in the elbow joint compared to primary radiography. In four (7%) patients a displaced fracture fragment was detected in primary radiography, but the origin of the fragment was unclear. In all four cases, MDCT revealed the origin of the fragment. Radiography remains the primary imaging modality in elbow trauma, but in complex fracture patterns, where the extent of the fractures and the position or origin of dislocated fragments is not clear by radiography, the MDCT is a recommended complementary examination.

  8. The story of 12 Chachapoyan mummies through multidetector computed tomography

    Friedrich, Klaus M., E-mail: klaus.friedrich@meduniwien.ac.at [Medical University Vienna, Department of Radiology, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Nemec, Stefan, E-mail: stefan.nemec@meduniwien.ac.at [Medical University Vienna, Department of Radiology, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Czerny, Christian, E-mail: christian.czerny@meduniwien.ac.at [Medical University Vienna, Department of Radiology, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Fischer, Helga, E-mail: helga.fischer@akhwien.at [Medical University Vienna, Department of Radiology, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Plischke, Sonja, E-mail: sonja.plischke@akhwien.at [Medical University Vienna, Department of Radiology, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Gahleitner, Andre, E-mail: andre.gahleitner@meduniwien.ac.at [Medical University Vienna, Department of Radiology, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Viola, Thomas Bence, E-mail: bence.viola@univie.ac.at [University of Vienna, Department of Anthropology, Althanstrasse 14, A-1091 Vienna (Austria); Imhof, Herwig, E-mail: herwig.imhof@meduniwien.ac.at [Medical University Vienna, Department of Radiology, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Seidler, Horst, E-mail: horst.seidler@univie.ac.at [University of Vienna, Department of Anthropology, Althanstrasse 14, A-1091 Vienna (Austria); Guillen, Sonja [University of Vienna, Department of Anthropology, Althanstrasse 14, A-1091 Vienna (Austria)

    2010-11-15

    Objective: To assess the imaging findings in Chachapoyan mummies of Peru through multidetector computed tomography (MDCT). Materials and methods: Twelve human mummies and three burial objects from Laguna de los Condores, Peru, about 500-1000 years old, were studied, using a MDCT unit. In addition to the standard whole-body acquisitions, high-resolution scans from areas of particular interest were acquired individually (e.g., temporal bone, teeth). Results: Eight mummies were female, three male, and sex was indeterminable in one mummy; the age of the mummies included newborn, 0.7 years, 2.5 years, 13 years, 13 years, 16 years, and six between 20 and 40 years old. The stature of the mummies was reconstructed (mean {+-} standard deviation; adults: 145 {+-} 14 cm, adolescents: 116 {+-} 17 cm, 2.5 years old child: 72 cm, newborns: 41 {+-} 3 cm). Dental conditions were compromised in seven and excellent in five mummies. Besides a dislocation of the ossicles, temporal bones and ears were normal in all mummies. An occipital osteoma, a tuberculous spondylodiscitis, and also probable tuberculous erosions at one tarsal joint and one sacral bone, osteoarthritis or tuberculous affection of a sacroiliac joint, as well as five cases of pulmonary tuberculosis were observed. Ten mummies were buried in the fetal position, two were found packaged in bundles; the burial technique was studied in detail. A necklace was found with one mummy. The added burial objects were identified as skeletal parts of two leopardis pardalis and one lagothrix flavicauda. Conclusions: MDCT non-invasively revealed information about age, sex, stature, diseases, burial practices and other cultural aspects of the Chachapoyas.

  9. Evaluation of left renal vein entrapment using multidetector computed tomography

    Poyraz, Ahmet K.; Onur, Mehmet R. [Dept. of Radiology, Firat Univ. School of Medicine, Elazig (Turkey)], e-mail: akursadpoyraz@yahoo.com.tr; Firdolas, Fatih [Dept. of Urology, Firat Univ. School of Medicine, Elazig (Turkey); Kocakoc, Ercan [Dept. of Radiology, Bezmialem Vakif Univ., School of Medicine, Istanbul (Turkey)

    2013-03-15

    Background: Nutcracker syndrome, also called left renal vein entrapment syndrome, is a cause of non-glomerular hematuria with difficulties in diagnosis. Multidetector computed tomography (MDCT) is a powerful tool to prevent unnecessary diagnostic procedures. Purpose: To retrospectively determine the prevalence of nutcracker phenomenon and nutcracker syndrome seen in MDCT in consecutive patients. Material and Methods: The institutional review board approved the study and waived the requirement for informed consent. Abdominal contrast-enhanced MDCT scans were reviewed from 1000 consecutive patients. MDCT scan assessment included renal vein diameter measurements and evaluation for the presence of anterior or posterior left renal vein entrapment. Electronic medical records and urine analysis reports of patients with left renal vein entrapment were reviewed. Student's t test was used to assess differences in renal vein diameter in patients with left renal vein entrapment. Results: Left renal vein entrapment was observed in 10.9% (109), retroaortic left renal vein in 6.5% (65), entrapment of left renal vein between superior mesenteric artery and aorta in 4.1% (41), and circumaortic left renal vein in 0.3% (3) of patients. Mean diameters of right (8.8 {+-} 1.9 mm) and unentrapped left (8.9 {+-} 1.8 mm) renal veins were not significantly different (P = 0.1). The mean diameter of anterior entrapped left renal veins (10.3 {+-} 2 mm) was significantly greater (P = 0.04) than contralateral renal veins (8.6 {+-} 2.1 mm) in their widest portion. In 8.8% of patients with the left renal vein entrapment, urine analysis showed isomorphic hematuria or proteinuria with no other known cause. Varicocele and pelvic congestion were seen in 5.5% of patients with the left renal vein entrapment. Conclusion: Left renal vein entrapment is not a rare entity and renal nutcracker phenomenon might be underdiagnosed.

  10. The story of 12 Chachapoyan mummies through multidetector computed tomography

    Objective: To assess the imaging findings in Chachapoyan mummies of Peru through multidetector computed tomography (MDCT). Materials and methods: Twelve human mummies and three burial objects from Laguna de los Condores, Peru, about 500-1000 years old, were studied, using a MDCT unit. In addition to the standard whole-body acquisitions, high-resolution scans from areas of particular interest were acquired individually (e.g., temporal bone, teeth). Results: Eight mummies were female, three male, and sex was indeterminable in one mummy; the age of the mummies included newborn, 0.7 years, 2.5 years, 13 years, 13 years, 16 years, and six between 20 and 40 years old. The stature of the mummies was reconstructed (mean ± standard deviation; adults: 145 ± 14 cm, adolescents: 116 ± 17 cm, 2.5 years old child: 72 cm, newborns: 41 ± 3 cm). Dental conditions were compromised in seven and excellent in five mummies. Besides a dislocation of the ossicles, temporal bones and ears were normal in all mummies. An occipital osteoma, a tuberculous spondylodiscitis, and also probable tuberculous erosions at one tarsal joint and one sacral bone, osteoarthritis or tuberculous affection of a sacroiliac joint, as well as five cases of pulmonary tuberculosis were observed. Ten mummies were buried in the fetal position, two were found packaged in bundles; the burial technique was studied in detail. A necklace was found with one mummy. The added burial objects were identified as skeletal parts of two leopardis pardalis and one lagothrix flavicauda. Conclusions: MDCT non-invasively revealed information about age, sex, stature, diseases, burial practices and other cultural aspects of the Chachapoyas.

  11. Comparison of Reconstruction Intervals in Routine ECG-Pulsed 64-Row-MSCT Coronary Angiography in Frequency Controlled Patients

    Purpose. In light of the increasing use and acceptance of multislice computed tomography (MSCT) coronary angiography it was the purpose of this study to compare reconstruction intervals used in a routine ECG-pulsed MSCT coronary artery angiography setting with frequency controlled patients. Methods. Examinations were performed on a Siemens Somatom Sensation 64 scanner with a total of 110 ml of contrast agent and ECG pulsing (interval from 40% to 70%) after oral application of a β-blocker if the heart rate was higher than 65 bpm. All human subjects were referred for the evaluation of suspected coronary artery disease. Coronary artery segments were evaluated by two experienced radiologists in a consensus reading. A ranking of diagnostic image quality (from 1 (no evaluation possible) to 5 (excellent image quality)) was statistically evaluated by Wilcoxon Signed Rank Test. Results. In 45 patients (30 male, 15 female, age 63.8 ± 12.1 years) we detected a significant advantage of the 60% reconstruction interval over 40%, 50%, and 70% (for each p < 0.05). In cases of sudden arrhythmia or movement during the scan, additional reconstruction intervals within the ECG-pulsed reconstruction intervals remained necessary for diagnosis. Conclusion. In a routine diagnostic setting with frequency controlled patients and ECG pulsing the 60% reconstruction interval can be considered superior for the initial diagnosis in 64-row multislice computed tomography coronary angiography. However, further information can be derived from various reconstruction intervals such as 40% and 70%

  12. Imaging features of double aortic arch shown by multidetector computed tomography angiography

    We present a three-dimensional reconstructed image of vascular ring in a 2.5-month-old patient, which was obtained using multidetector computed tomography (MDCT). MDCT angiography made an accurate diagnosis of this life-threatening, but correctable, anomaly in an infant with a stridor, repeated respiratory infections and episodes of apnea

  13. Multidetector-Row Computed Tomography Imaging Characteristics of Mechanical Prosthetic Valves

    P. Symersky; R.P.J. Budde; M. Prokop; B.A.J.M. de Mol

    2011-01-01

    Background and aim of the study: Electrocardiogram-gated multidetector-row computed tomography (MDCT) imaging may aid in the evaluation of prosthetic valve dysfunction. A pulsatile in vitro model was developed to study the MDCT imaging characteristics of mechanical heart valves (MHVs). Methods: Bjor

  14. Multidetector-row computed tomography imaging characteristics of mechanical prosthetic valves

    Symersky, P.; Budde, R.P.; Prokop, M.; Mol, B.A. de

    2011-01-01

    BACKGROUND AND AIM OF THE STUDY: Electrocardiogram-gated multidetector-row computed tomography (MDCT) imaging may aid in the evaluation of prosthetic valve dysfunction. A pulsatile in vitro model was developed to study the MDCT imaging characteristics of mechanical heart valves (MHVs). METHODS: Bjor

  15. Diagnosis of spinal dural arteriovenous fistula with multidetector row computed tomography: a case report

    Bertrand, D.; Douvrin, F.; Gerardin, E.; Clavier, E.; Thiebot, J. [Rouen University Hospital, Department of Radiology, Rouen (France); Proust, F. [Rouen University Hospital, Department of Neurosurgery, Rouen (France)

    2004-10-01

    Spinal dural arteriovenous fistulas are a rare cause of myelopathy. Nonspecific symptoms may delay the diagnosis. Magnetic resonance imaging and spinal angiography are routinely used to establish the diagnosis. In our case abnormalities on magnetic resonance imaging only suggested spinal dural arteriovenous fistulas. Multidetector row computed tomography (MRCT) led to the diagnosis which was confirmed by angiography. (orig.)

  16. Diagnosis of spinal dural arteriovenous fistula with multidetector row computed tomography: a case report

    Spinal dural arteriovenous fistulas are a rare cause of myelopathy. Nonspecific symptoms may delay the diagnosis. Magnetic resonance imaging and spinal angiography are routinely used to establish the diagnosis. In our case abnormalities on magnetic resonance imaging only suggested spinal dural arteriovenous fistulas. Multidetector row computed tomography (MRCT) led to the diagnosis which was confirmed by angiography. (orig.)

  17. Multidetector computed tomography pulmonary angiography in childhood acute pulmonary embolism

    Pulmonary embolism is a life-threatening condition affecting people of all ages. Multidetector row CT pulmonary angiography has improved the imaging of pulmonary embolism in both adults and children and is now regarded as the routine modality for detection of pulmonary embolism. Advanced CT pulmonary angiography techniques developed in recent years, such as dual-energy CT, have been applied as a one-stop modality for pulmonary embolism diagnosis in children, as they can simultaneously provide anatomical and functional information. We discuss CT pulmonary angiography techniques, common and uncommon findings of pulmonary embolism in both conventional and dual-energy CT pulmonary angiography, and radiation dose considerations. (orig.)

  18. Multidetector computed tomography pulmonary angiography in childhood acute pulmonary embolism

    Tang, Chun Xiang; Zhang, Long Jiang; Lu, Guang Ming [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Schoepf, U.J. [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Department of Pediatrics, Charleston, SC (United States); Chowdhury, Shahryar M. [Medical University of South Carolina, Department of Pediatrics, Charleston, SC (United States); Fox, Mary A. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States)

    2015-09-15

    Pulmonary embolism is a life-threatening condition affecting people of all ages. Multidetector row CT pulmonary angiography has improved the imaging of pulmonary embolism in both adults and children and is now regarded as the routine modality for detection of pulmonary embolism. Advanced CT pulmonary angiography techniques developed in recent years, such as dual-energy CT, have been applied as a one-stop modality for pulmonary embolism diagnosis in children, as they can simultaneously provide anatomical and functional information. We discuss CT pulmonary angiography techniques, common and uncommon findings of pulmonary embolism in both conventional and dual-energy CT pulmonary angiography, and radiation dose considerations. (orig.)

  19. Hepatobiliary diseases in small animals: a comparison of ultrasonography and multidetector-row computed tomography

    Borsetto, Antonella

    2011-01-01

    Ultrasonography (US) is an essential imaging tool for identifying abnormalities of the liver parenchyma, biliary tract and vascular system. US has replaced radiography as the initial imaging procedure in screening for liver disease in small animals. There are few reports of the use of conventional and helical computed tomography (CT) to assess canine or feline parenchymal and neoplastic liver disease and biliary disorders. In human medicine the development of multidetector- row helical comput...

  20. Using Multidetector Row Computed Tomography to Diagnose and Stage Pancreatic Carcinoma: the Problems and the Possibilities

    Rotondo A

    2005-01-01

    Full Text Available The sensitivity of computed tomography (CT in the diagnosis of pancreatic neoplasms and accurate tumor staging has significantly been improved by the use of thin-section multi-detector row CT techniques. Greater table speed, improved tube cooling, high resolution imaging and the possibility of isotropic voxels have led to optimal multiplanar reconstruction in any arbitrary plane and particularly along the pancreatic duct and peripancreatic vessels, significantly improving the detection of small pancreatic tumors and surgical resectability where imaging modalities have so far yielded disappointing results. Nonetheless, while multi-detector row CT has greatly enhanced the imaging capabilities of CT, early diagnosis is practically impossible to achieve, since the tumor remains asymptomatic until the surrounding structures are involved. Furthermore, even when treated with radical surgery, the incidence of recurrence is high and the prognosis of pancreatic carcinoma still remains extremely poor and has not changed over the past years. In this article, the recent technical developments of multi-detector row CT in diagnosing pancreatic neoplasms and staging are considered, with special emphasis on multi-detector row CT angiography techniques and curved planar reformations. Some remaining challenging problems such as the pre-operative identification and characterization of small hepatic lesions and detection of omental and peritoneal metastasis, the diagnosis of small isoattenuating pancreatic adenocarcinomas and promising strategies to differentiate between pancreatic adenocarcinoma and chronic inflammatory changes are also presented.

  1. A case report of a normal aorta misdiagnosed as type A dissection by modern multidetector computed tomography

    Hamilton, M.C.K. [Bristol Heart Institute, Bristol Royal Infirmary, Department of Radiology, Bristol (United Kingdom); Nightingale, A.K.; Stuart, A.G. [Bristol Heart Institute, Bristol Royal Infirmary, Department of Cardiology, Bristol (United Kingdom); Masey, S. [Bristol Heart Institute, Bristol Royal Infirmary, Department of Cardiac Anaesthesia, Bristol (United Kingdom); Angelini, G. [Bristol Heart Institute, Bristol Royal Infirmary, Department of Cardiac Surgery, Bristol (United Kingdom); Hopkins, R.; McGann, G. [Cheltenham Hospital, Department of Diagnostic Radiology, Cheltenham (United Kingdom)

    2010-08-15

    Computed tomography (CT) is generally considered the investigation of choice to exclude acute aortic syndrome. We report an important potentially disastrous misdiagnosis using a modern 32 slice multidetector CT system. (orig.)

  2. Diagnostic ability of Barrett's index to detect dysthyroid optic neuropathy using multidetector computed tomography

    Objectives: The objective of this study was to evaluate the ability of a muscular index (Barrett's Index), calculated with multidetector computed tomography, to detect dysthyroid optic neuropathy in patients with Graves' orbitopathy. Methods: Thirty-six patients with Graves' orbitopathy were prospectively studied and submitted to neuro-ophthalmic evaluation and multidetector computed tomography scans of the orbits. Orbits were divided into two groups: those with and without dysthyroid optic neuropathy. Barrett's index was calculated as the percentage of the orbit occupied by muscles. Sensitivity and specificity were determined for several index values. Results: Sixty-four orbits (19 with and 45 without dysthyroid optic neuropathy) met the inclusion criteria for the study. The mean Barrett's index values (±SD) were 64.47% ± 6.06% and 49.44% ± 10.94% in the groups with and without dysthyroid optic neuropathy, respectively (p60% should be carefully examined and followed for the development of dysthyroid optic neuropathy. (author)

  3. Hemobilia in a child due to right hepatic artery pseudoaneurysm: Multidetector-row computed tomography demonstration

    Nisar A Wani

    2011-01-01

    Full Text Available We present a case of a 12-year-old boy who developed upper gastrointestinal bleeding in the form of hematemesis and melena 1 month after blunt trauma to liver. Computed tomography (CT angiography with multidetector-row CT demonstrated pseudoaneurysm of right hepatic artery related to old liver laceration to be the cause of the bleeding. Pseudoaneurysm was resected using the roadmap provided by CT angiography findings.

  4. The value of contrast-enhanced 64-row CT in differentiating benign from malignant serous ovarian neoplasms

    Objective: To assess the diagnostic value of contrast-enhanced 64-row CT scanning in deciding benign or malignant serous ovarian tumors. Methods: Fifty-eight cases of serous ovarian tumors proved pathologically were reviewed, including 25 malignant tumors, 25 benign, 8 borderline tumors. All patients underwent 64-row CT scanning, including plain scanning and contrast-enhance scanning. The tumors' shape, density, blood supply and enhancement features were evaluated. Results: Twenty-five cases of benign serous cystic adenoma were mostly unicameral, and showed a moderate mural enhancement only in 4 cases (16%) due to chronic pelvic infection and the others (21/25, 84%) had no of slight enhancement. Malignant tumors were cystic-solid mass with unclear margin, irregular shape and septa. Twenty-two cases of serous cystadenocarcinoma out of 25 cases (88%) appeared obvious enhancement and other 3 cases no enhancement. And 7 cases out of 8 (87.5%) borderlined serous cystadenomas showed different enhancement patterns. Conclusion: Benign ovarian serous neoplasms were mostly unicameral and no strong mural enhancement, suggesting a lack of blood supply. While, there were obvious enhancement in the ovarian serous cystadenocarcinoma and borderline serous cystadenoma with malignant potential. The 64-row CT is helpful for differentiating the nature of the serous ovarian neoplasm. (authors)

  5. Multiplanar and two-dimensional imaging of central airway stenting with multidetector computed tomography

    Ozgul Mehmet

    2012-08-01

    Full Text Available Abstract Background Multidetector computed tomography (MDCT provides guidance for primary screening of the central airways. The aim of our study was assessing the contribution of multidetector computed tomography- two dimensional reconstruction in the management of patients with tracheobronchial stenosis prior to the procedure and during a short follow up period of 3 months after the endobronchial treatment. Methods This is a retrospective study with data collected from an electronic database and from the medical records. Patients evaluated with MDCT and who had undergone a stenting procedure were included. A Philips RSGDT 07605 model MDCT was used, and slice thickness, 3 mm; overlap, 1.5 mm; matrix, 512x512; mass, 90 and kV, 120 were evaluated. The diameters of the airways 10 mm proximal and 10 mm distal to the obstruction were measured and the stent diameter (D was determined from the average between D upper and D lower. Results Fifty-six patients, 14 (25% women and 42 (75% men, mean age 55.3 ± 13.2 years (range: 16-79 years, were assessed by MDCT and then treated with placement of an endobronchial stent. A computed tomography review was made with 6 detector Philips RSGDT 07605 multidetector computed tomography device. Endobronchial therapy was provided for the patients with endoluminal lesions. Stents were placed into the area of stenosis in patients with external compression after dilatation and debulking procedures had been carried out. In one patient the migration of a stent was detected during the follow up period by using MDCT. Conclusions MDCT helps to define stent size, length and type in patients who are suitable for endobronchial stinting. This is a non-invasive, reliable method that helps decisions about optimal stent size and position, thus reducing complications.

  6. Bosniak classification of renal cystic lesions according to multidetector computed tomography findings; Classificacao de Bosniak das lesoes cisticas renais segundo achados na tomografia computadorizada multidetectores

    Miranda, Christiana Maia Nobre Rocha de; Padilha, Igor Gomes; Farias, Lucas de Padua Gomes de; Rocha, Milzi Sarmento da, E-mail: maiachristiana@globo.com [Universidade Federal de Alagoas (UFAL), Maceio, AL (Brazil); Maranhao, Carol Pontes de Miranda; Santos, Carla Jotta Justo dos [Clinica de Medicina Nuclear e Radiologia de Maceio (MedRadiUS), Maceio, AL (Brazil)

    2014-03-15

    Renal cystic lesions are usually diagnosed in the radiologists' practice and therefore their characterization is crucial to determine the clinical approach to be adopted and prognosis. The Bosniak classification based on computed tomography findings has allowed for standardization and categorization of lesions in increasing order of malignancy (I, II, IIF, III and IV) in a simple and accurate way. The present iconographic essay developed with multidetector computed tomography images of selected cases from the archives of the authors' institution, is aimed at describing imaging findings that can help in the diagnosis of renal cysts. (author)

  7. Calcium score of small coronary calcifications on multidetector computed tomography

    Groen, J M; Kofoed, K F; Zacho, M;

    2013-01-01

    Multi detector computed tomography (MDCT) underestimates the coronary calcium score as compared to electron beam tomography (EBT). Therefore clinical risk stratification based on MDCT calcium scoring may be inaccurate. The aim of this study was to assess the feasibility of a new phantom which...

  8. Absence of a sphenoid wing in neurofibromatosis type 1 disease: imaging with multidetector computed tomography

    Neurofibromatosis type 1 disease if characterized by pigmented cutaneous lesions and generalized tumors of a neural crest origin and it may affect all the systems of the human body. Sphenoid dysplasia is one of the characteristics of this syndrome and it occurs in 5-10% of the cases; further, abnormalities of the sphenoid wings are often considered pathognomonic. However, complete agenesis of a sphenoid wing is very rare. We report here on an unusual case of neurofibromatosis type 1 disease with the associated absence of a sphenoid wing that was diagnosed by using multidetector computed tomography

  9. Absence of a sphenoid wing in neurofibromatosis type 1 disease: imaging with multidetector computed tomography

    Onbas, Omer; Aliagaoglu, Cihangir; Calikoglu, Cagatay; Kantarci, Mecit; Atasoy, Mustafa; Alper, Fatih [Ataturk University, Erzurum (Turkmenistan)

    2006-03-15

    Neurofibromatosis type 1 disease if characterized by pigmented cutaneous lesions and generalized tumors of a neural crest origin and it may affect all the systems of the human body. Sphenoid dysplasia is one of the characteristics of this syndrome and it occurs in 5-10% of the cases; further, abnormalities of the sphenoid wings are often considered pathognomonic. However, complete agenesis of a sphenoid wing is very rare. We report here on an unusual case of neurofibromatosis type 1 disease with the associated absence of a sphenoid wing that was diagnosed by using multidetector computed tomography.

  10. Follicular Dendritic Cell Sarcoma of the Omentum: Multidetector Computed Tomography Findings

    We report computed tomography (CT) findings for a rare case of follicular dendritic cell sarcoma of the greater omentum from a 47-year-old female patient. The tumor presented ash a palpable mass lesion in the umbilical region for the last two months. Multidetector CT scan of the abdomen showed a 14-cm soft-tissue mass with calcification and necrosis within the greater omentum. As a result, a follicular dendritic cell sarcoma should be considered in the differential diagnosis of a solitary omentum mass, especially one with coarse and chunk-like calcifications

  11. Multidetector computed tomography imaging of congenital anomalies of major airways: A pictorial essay.

    Sundarakumar, Dinesh Kumar; Bhalla, Ashu Seith; Sharma, Raju; Gupta, Arun Kumar; Kabra, Susheel Kumar; Jagia, Priya

    2011-12-28

    Congenital airway anomalies can be asymptomatic or may cause severe respiratory distress requiring immediate treatment. These anomalies can present early in life, or may be just incidental findings. It is important to recognize these entities to realize their clinical significance and to avoid false diagnosis. In this article, the various congenital airway anomalies and their imaging features by multidetector computed tomography (MDCT) are reviewed in order of occurrence during the embryological timeline. This pictorial essay reviews the various distinct congenital airway lesions and their MDCT manifestations. It also provides insight into the embryological basis of the congenital airway lesions encountered. PMID:22224177

  12. Multidetector computed tomography of urolithiasis. Technique and results; Multidetektor-Computertomografie der Urolithiasis. Technik und Ergebnisse

    Karul, M.; Regier, M. [Universitaetsklinikum Hamburg-Eppendorf, Hamburg (Germany). Zentrum fuer Radiologie und Endoskopie; Heuer, R. [Universitaetsklinikum Hamburg-Eppendorf, Hamburg (Germany). Zentrum fuer Operative Medizin

    2013-02-15

    The diagnosis of acute urolithiasis results from unenhanced multidetector computed tomography (MDCT). This test analyses the functional and anatomical possibility for passing an ureteral calculi, the localization and dimension of which are important parameters for further therapy. Alternatively chronic urolithiasis could be ruled out by magnetic resonance urography (MRU). MRU is the first choice especially in pregnant women and children because of radiation hygiene. Enhanced MDCT must be emphasized as an alternative to intravenous urography (IVU) for diagnosis of complex drainage of urine and suspected disorder of the involved kidney. This review illustrates the principles of different tests and the clinical relevance thereof. (orig.)

  13. Multidetector computed tomography-spectrum of blunt chest wall and lung injuries in polytraumatized patients

    Peters, S., E-mail: soeren.peters@rub.d [Department of Radiology and Nuclear Medicine, BG Universitaetsklinikum Bergmannsheil, Buerkle-de-la-Camp-Platz 1, 44789 Bochum (Germany); Nicolas, V.; Heyer, C.M. [Department of Radiology and Nuclear Medicine, BG Universitaetsklinikum Bergmannsheil, Buerkle-de-la-Camp-Platz 1, 44789 Bochum (Germany)

    2010-04-15

    Accidental injuries are the leading cause of death in the 15 to 44-year-old age group. Blunt chest trauma is often encountered in these patients and is associated with a mortality of up to 25%. Although conventional radiography still plays an important role in the initial emergency room setting, for follow-up in the intensive care unit, multidetector computed tomography has established itself as the standard imaging method for the evaluation of chest trauma patients. The following review presents salient radiological findings of the chest wall and shoulder girdle, thoracic spine, pleural space, and lung in polytraumatized patients.

  14. Contrast-enhanced ultrasound vs multidetector-computed tomography for detecting liver metastases in colorectal cancer: a prospective, blinded, patient-by-patient analysis

    Rafaelsen, S R; Jakobsen, A

    2011-01-01

    This study compared the sensitivity and specificity of contrast-enhanced ultrasound (CEUS) and multidetector-computed tomography (MDCT) in the detection of liver metastases in patients with colorectal cancer.......This study compared the sensitivity and specificity of contrast-enhanced ultrasound (CEUS) and multidetector-computed tomography (MDCT) in the detection of liver metastases in patients with colorectal cancer....

  15. Sex estimation from sternal measurements using multidetector computed tomography.

    Ekizoglu, Oguzhan; Hocaoglu, Elif; Inci, Ercan; Bilgili, Mustafa Gokhan; Solmaz, Dilek; Erdil, Irem; Can, Ismail Ozgur

    2014-12-01

    We aimed to show the utility and reliability of sternal morphometric analysis for sex estimation.Sex estimation is a very important step in forensic identification. Skeletal surveys are main methods for sex estimation studies. Morphometric analysis of sternum may provide high accuracy rated data in sex discrimination. In this study, morphometric analysis of sternum was evaluated in 1 mm chest computed tomography scans for sex estimation. Four hundred forty 3 subjects (202 female, 241 male, mean age: 44 ± 8.1 [distribution: 30-60 year old]) were included the study. Manubrium length (ML), mesosternum length (2L), Sternebra 1 (S1W), and Sternebra 3 (S3W) width were measured and also sternal index (SI) was calculated. Differences between genders were evaluated by student t-test. Predictive factors of sex were determined by discrimination analysis and receiver operating characteristic (ROC) analysis. Male sternal measurement values are significantly higher than females (P < 0.001) while SI is significantly low in males (P < 0.001). In discrimination analysis, MSL has high accuracy rate with 80.2% in females and 80.9% in males. MSL also has the best sensitivity (75.9%) and specificity (87.6%) values. Accuracy rates were above 80% in 3 stepwise discrimination analysis for both sexes. Stepwise 1 (ML, MSL, S1W, S3W) has the highest accuracy rate in stepwise discrimination analysis with 86.1% in females and 83.8% in males. Our study showed that morphometric computed tomography analysis of sternum might provide important information for sex estimation. PMID:25501090

  16. Visibility of sutures of the orbit and periorbital region using multidetector computed tomography

    Gufler, Hubert; Preis, Markus; Koesling, Sabrina [Dept. of Diagnostic Radiology, Martin-Luther-University Halle-Wittenberg, Halle (Germany)

    2014-12-15

    Knowledge of cranial suture morphology is crucial in emergency medicine, forensic medicine, and maxillofacial reconstructive surgery. This study assessed the visibility of sutures of the orbit and periorbital region on multidetector computed tomography. Multidetector computed tomography scans of 200 patients (127 males, 73 females; mean age 51.3 years; range, 6-92 years) were evaluated retrospectively. The slice thicknesses varied from 0.5 to 1 mm, and the tube current from 25 to 370 mAs, depending on the CT indication. The visibility of sutures was estimated according to a 4-point scale from 'not visible to well visible' The chi-squared test was used to test the association of the visibility of sutures with the slice thickness, tube current, and age of patients. Statistical significance was assumed at p < 0.05. Overall, best visibility was found for the sutura frontozygomatica (98%), sutura frontonasalis (88.5%), and sutura sphenozygomatica (71.5%), followed by the sutura zygomaticomaxillaris (65.8%), sutura temporozygomatica (41.8%), sutura frontomaxillaris (44.5%), and sutura sphenofrontalis (31%). Poor visibility was found for the sutura frontolacrimalis (16.8%) and sutura frontoethmoidalis (1.3%). The sutura ethmoidomaxillaris, sutura lacrimomaxillaris, and sutura ethmoidolacrimalis were not visible. Although the sutures of the superior, lateral, and inferior orbit are well visible, those of the medial orbit are poorly visible on CT scans.

  17. Multidetector computed tomography angiography of the renal arteries: normal anatomy and its variations*

    de Mello Júnior, Carlos Fernando; Araujo Neto, Severino Aires; de Carvalho Junior, Arlindo Monteiro; Rebouças, Rafael Batista; Negromonte, Gustavo Ramalho Pessoa; de Oliveira, Carollyne Dantas

    2016-01-01

    Conventional angiography is still considered the gold standard for the study of the anatomy and of vascular diseases of the abdomen. However, the advent of multidetector computed tomography and techniques of digital image reconstruction has provided an alternative means of performing angiography, without the risks inherent to invasive angiographic examinations. Therefore, within the field of radiology, there is an ever-increasing demand for deeper knowledge of the anatomy of the regional vasculature and its variations. Variations in the renal vascular system are relatively prevalent in the venous and arterial vessels. For various conditions in which surgical planning is crucial to the success of the procedure, knowledge of this topic is important. The aim of this study was to familiarize the general radiologist with variations in the renal vascular system. To that end, we prepared a pictorial essay comprising multidetector computed tomography images obtained in a series of cases. We show patterns representative of the most common anatomical variations in the arterial blood supply to the kidneys, calling attention to the nomenclature, as well as to the clinical and surgical implications of such variations.

  18. Diagnostic ability of barrett's index to detect dysthyroid optic neuropathy using multidetector computed tomography

    Mário L. R. Monteiro

    2008-01-01

    Full Text Available OBJECTIVES: The objective of this study was to evaluate the ability of a muscular index (Barrett's Index, calculated with multidetector computed tomography, to detect dysthyroid optic neuropathy in patients with Graves' orbitopathy. METHODS: Thirty-six patients with Graves' orbitopathy were prospectively studied and submitted to neuro-ophthalmic evaluation and multidetector computed tomography scans of the orbits. Orbits were divided into two groups: those with and without dysthyroid optic neuropathy. Barrett's index was calculated as the percentage of the orbit occupied by muscles. Sensitivity and specificity were determined for several index values. RESULTS: Sixty-four orbits (19 with and 45 without dysthyroid optic neuropathy met the inclusion criteria for the study. The mean Barrett's index values (± SD were 64.47% ± 6.06% and 49.44% ± 10.94%in the groups with and without dysthyroid optic neuropathy, respectively (p60% should be carefully examined and followed for the development of dysthyroid optic neuropathy.

  19. Normal mediastinal and hilar lymph nodes in children on multi-detector row chest computed tomography

    To study normal mediastinal and hilar lymph nodes on multi-detector chest computed tomography (CT). A cohort of 120 children aged 1-17 years underwent emergency CT, including the chest, after high-energy trauma. Axial 5-mm reconstructions were evaluated for lymph nodes at hilar and various mediastinal levels and the short-axis diameters were measured. At least one lymph node was found in 115 (96%) children, with subcarinal (69%), lower paratracheal (64%) and hilar (60%) nodes being most common. Up to 10 years of age most lymph nodes were smaller than or equal to 7 mm. In older children lymph nodes measuring up to 10-mm-short-axis diameter were found. Lymph nodes were rare along the mammary vessels, at lower oesophageal and at prevascular and posterior mediastinal levels in children. Mediastinal and hilar lymph nodes are more common than previously thought, probably because of increased detection by modern multi-detector CT. Lymph node location and age have to be taken into account when evaluating lymph nodes in the paediatric chest. (orig.)

  20. [Multidetector computed tomography of coronary arteries: state of the art. Second part: clinical applications].

    González, Aloha Meave; Rosas, Erick Alexánderson; Valero, Mónica Rodríguez; Ramírez, Gabriela Meléndez; García, Alfonso Martínez; Fernández, Carlos Sierra; Torres, Rodrigo Calleja; Castillo, Leonardo García-Rojas; Molina, Pedro Alberto Lamothe; Zarza, Mary Carmen Herrera; de Avila, Martha Armas; López, Juan Manuel Ochoa; Vázquez-Lamadrid, Jorge; Hayama, Eric Kimura

    2008-01-01

    At the beginning of the evaluation of Coronary Artery Disease (CAD), Coronary Multidetector Computed Tomography (MDCT) was exclusively used to detect calcified plaques in coronary arteries through the Calcium Score, whose value by itself is limited. Nowadays, thanks to the technological advancements, potential clinical applications, with this method, include detection of coronary arterial stenosis, assessment of coronary bridges, and evaluation of anomalous coronaries. The intraluminal coronary stent evaluation is not possible yet, but this might become possible with the new-generation scanners. At the moment, the published results seem to be promising, nonetheless, the enthusiasm generated by this method should be accompanied by adequate training, as well as by its validation and certification. PMID:18754411

  1. Multiparametric multidetector computed tomography scanning on suspicion of hyperacute ischemic stroke: validating a standardized protocol

    Felipe Torres Pacheco

    2013-06-01

    Full Text Available Multidetector computed tomography (MDCT scanning has enabled the early diagnosis of hyperacute brain ischemia. We aimed at validating a standardized protocol to read and report MDCT techniques in a series of adult patients. The inter-observer agreement among the trained examiners was tested, and their results were compared with a standard reading. No false positives were observed, and an almost perfect agreement (Kappa>0.81 was documented when the CT angiography (CTA and cerebral perfusion CT (CPCT map data were added to the noncontrast CT (NCCT analysis. The inter-observer agreement was higher for highly trained readers, corroborating the need for specific training to interpret these modern techniques. The authors recommend adding CTA and CPCT to the NCCT analysis in order to clarify the global analysis of structural and hemodynamic brain abnormalities. Our structured report is suitable as a script for the reproducible analysis of the MDCT of patients on suspicion of ischemic stroke.

  2. Anomalies of abdominal organs in polysplenia syndrome: Multidetector computed tomography findings

    Kim, Sung Won; Lee, Yong Seok; Jung, Jin Hee [Dept. of Radiology, Dongguk University Ilsan Hospital, Dongguk University School of Medicine, Goyang (Korea, Republic of)

    2016-02-15

    Polysplenia syndrome is a rare situs ambiguous anomaly associated with multiple spleens and anomalies of abdominal organs. Because most of the minor anomalies do not cause clinical symptoms, polysplenia syndrome is detected incidentally in the adults. Anomalies of abdominal organs may include multiple spleens of variable size or right-sided spleen, large midline or left-sided liver, midline gallbladder, biliary tract anomalies, short pancreas, right-sided stomach, intestinal malrotation, inferior vena cava interruption with azygos or hemiazygos continuation, and a preduodenal portal vein. As the multidetector computed tomography is increasingly used, situs anomalies will likely to be found with greater frequency in the adults. Therefore, radiologists should become familiar with these rare and peculiar anomalies of abdominal organs in polysplenia syndrome.

  3. Usefulness of multidetector computed tomography in the diagnosis of lower gastrointestinal diverticular hemorrhage

    The aim of this study was to evaluate the diagnostic ability of Multidetector Computed Tomography (MDCT) for lower gastrointestinal diverticular hemorrhage. Three radiologists reviewed MDCT findings in 12 cases and investigated the relationship between imaging findings and the patients' blood pressure, volume of transfusion, and treatments applied. MDCT examination demonstrated ''extravasation'' in 7 cases, and luminal abnormalities, id est (i.e.), ''high density area with bubble'', ''fluid collection'' and ''clot'' in 5, 8, and 4 cases, respectively. Four of six cases who required blood transfusion demonstrated extravasation. The systolic blood pressure of three cases with extravasation was below 95 mmHg. Extravasation on MDCT which was frequently observed in patients with hypotension and/or requiring blood transfusion, was highly specific for diagnosing the bleeding site. MDCT was also useful for procedural planning in IVR, endoscopic and surgical management. (author)

  4. Evaluation of visibility of lumen of coronary stents by CT coronary angiography using multi-detector row CT in our hospital

    Many experiments of evaluation of coronary stents by CT coronary angiography (CTCA) using multi-detector row computed tomography (MDCT) are reported since the appearance of 16-row and 64-row CT. However, blooming artifact makes the assessment of lumen of coronary stent (LCS) difficult at present. The purpose of this study is to investigate the evaluation of visibility of LCS by CTCA. CTCA was performed in 25 patients who had previously undergone stent implantation scanned using 64-row CT, and images of 32 stents were obtained. All images were classified into 4 grades (4: excellent, 3: good, 2: fair, 1: poor) according to their visibility of LCS. We investigated the correlation of stent characteristics and backgrounds (diameter, material and thickness of strut, the period from stent implantation to CTCA, the location of stent, and whether calcification or not) with the grade of visibility. We found the conditions of good visibility of LCS were the diameter >3.5 mm (ratio of ≥grade 3 was 77.8%=14/18 stents), thin strut (<100 μm), and no calcification (ratio of ≥grade 3 was 87.5%=14/16 stents). We expected that CTCA using MDCT will be established useful examination of evaluation of LCS in future. (author)

  5. Multi-detector Computed Tomography Angiography of the Hepatic Artery in Liver Transplant Recipients

    PURPOSE: To evaluate the ability of multi-detector row computed tomography angiography (CTA) in detecting hepatic artery complications in the follow-up of liver transplant patients, performing volume-rendering as reconstruction technique. MATERIAL AND METHODS: The anatomy of hepatic artery was studied in 27 liver transplant recipients with a four-row CT scanner using the following parameters: collimation, 1 mm; slice width, 1 mm; table feed, 6-8 mm/s; spiral reconstruction time, 0.5 s; reconstruction interval, 0.5 mm; mAs, 160; kVp, 120. Before the study, the patients received 1000 ml of water as oral contrast agent to produce negative contrast in the stomach and the small bowel. A non-ionic contrast medium was infused intravenously at a rate of 5 ml/s with a bolus tracking system. Volume-rendering of hepatic artery was performed with the 3D Virtuoso software. RESULTS: The celiac trunk, the hepatic artery, and the right and left hepatic arteries were successfully displayed in high detail in all patients. Side branches, including small collaterals, and hepatic artery anastomosis could also be readily visualized. Volume-rendered CTA detected six hepatic artery stenoses, two hepatic artery thromboses, and two intrahepatic pseudoaneurysms. In two cases, CT detected hepatic artery stenosis with a diameter reduction of less than 50%, while digital subtraction angiography showed a normal artery. CONCLUSION: Volume-rendered multi-detector CTA is a promising non-invasive technique, since it allows images of high quality to be generated with excellent anatomical visualization of the hepatic artery and its complications in liver transplant recipients

  6. Multi-detector Computed Tomography Angiography of the Hepatic Artery in Liver Transplant Recipients

    Boraschi, P.; Donati, F.; Cossu, M.C.; Gigoni, R.; Vignali, C.; Filipponi, F.; Bartolozzi, C.; Falaschi, F. [Pisa Univ. Hospital (Italy). 2nd Dept. of Radiology

    2005-08-01

    PURPOSE: To evaluate the ability of multi-detector row computed tomography angiography (CTA) in detecting hepatic artery complications in the follow-up of liver transplant patients, performing volume-rendering as reconstruction technique. MATERIAL AND METHODS: The anatomy of hepatic artery was studied in 27 liver transplant recipients with a four-row CT scanner using the following parameters: collimation, 1 mm; slice width, 1 mm; table feed, 6-8 mm/s; spiral reconstruction time, 0.5 s; reconstruction interval, 0.5 mm; mAs, 160; kVp, 120. Before the study, the patients received 1000 ml of water as oral contrast agent to produce negative contrast in the stomach and the small bowel. A non-ionic contrast medium was infused intravenously at a rate of 5 ml/s with a bolus tracking system. Volume-rendering of hepatic artery was performed with the 3D Virtuoso software. RESULTS: The celiac trunk, the hepatic artery, and the right and left hepatic arteries were successfully displayed in high detail in all patients. Side branches, including small collaterals, and hepatic artery anastomosis could also be readily visualized. Volume-rendered CTA detected six hepatic artery stenoses, two hepatic artery thromboses, and two intrahepatic pseudoaneurysms. In two cases, CT detected hepatic artery stenosis with a diameter reduction of less than 50%, while digital subtraction angiography showed a normal artery. CONCLUSION: Volume-rendered multi-detector CTA is a promising non-invasive technique, since it allows images of high quality to be generated with excellent anatomical visualization of the hepatic artery and its complications in liver transplant recipients.

  7. Effect of dose-reduced scan protocols on cardiac coronary image quality with 64-row MDCT: A cardiac phantom study

    Objective: To evaluate the feasibility of using relative low-dose scan protocols in coronary imaging with 64-row MDCT. Materials and methods: A pulsating cardiac phantom was used to simulate coronary arteries of two sizes (3 and 5 mm in diameter) with three stenosis degrees (25, 50 and 75%) at 55 bpm heart rate. Cardiac scans were performed on a 64-row MDCT scanner (GE LightSpeed VCT) with rotation time of 350 ms and pitch of 0.2 under six different scan protocols: 120 kV/650 mA, 1137.5 mAs (effective) (CTDIvol 121.69 mGy), 120 kV/550 mA, 962.5 mAs (CTDIvol 102.96 mGy), 120 kV/450 mA, 787.5 mAs (CTDIvol 84.24 mGy), 120 kV/350 mA, 612.5 mAs (CTDIvol 65.52 mGy), 100 kV/590 mA, 1032.5 mAs (CTDIvol 65.17 mGy) and 140 kV/390 mA, 682.5 mAs (CTDIvol 102.22 mGy). The simulative coronary arteries were filled with contrast media to reach 300 HU in the lumen. Background noise was measured to describe the basic image quality accordingly. CNR, SNR and contour sharpness represented in slope of CT density curve was calculated as well. Measured stenosis area and rates, described by the percentage area of stenosis on the cross-section images were also calculated. Results: The corresponding image noise levels described in standard deviation of background signals varied with radiation dose, CNR and SNR mainly varied with tube current. The contour sharpness, which can reflect actual spatial resolution, is affected mainly by tube voltage. The first five protocols depicted obviously steeper curves than the sixth one (P 0.05). As for evaluation on 50 and 75% stenosis, there was no significant difference between the first two protocols, and between the second two protocols as well. However, significant difference presented between these two groups (P > 0.05). When comparing the groups with similar radiation dose, protocols with lower tube voltage gain more accuracy in representing stenosis area and rate. Conclusion: Dose level and corresponding image quality is relevant to the accuracy of

  8. Dose related, comparative evaluation of a novel bone-subtraction algorithm in 64-row cervico-cranial CT angiography

    Siebert, E.; Bohner, G. [Department of Neuroradiology, Charite Universitary Medicine Berlin (Germany); Dewey, M.; Bauknecht, C. [Department of Radiology, Charite Universitary Medicine Berlin (Germany); Klingebiel, R. [Department of Neuroradiology, Charite Universitary Medicine Berlin (Germany)], E-mail: randolf.klingebiel@charite.de

    2010-01-15

    Purpose: Comparative evaluation of a low-dose scan protocol for a novel bone-subtraction (BS) algorithm, applicable to 64-row cervico-cranial (cc) CT angiography (MSCTA). Methods and patients: BS algorithm assessment was performed in cadaveric phantom studies by stepwise variation of tube current and head malrotation using a 64-row CT scanner. In order to define minimum dose requirements and the rotation correction capacity, a low dose BS MSCTA protocol was defined and evaluated in 12 patients in comparison to a common manual bone removal algorithm. Standard MIPs of both modalities were evaluated in a blinded manner by two neuroradiologists for image quality composed, of vessel contour sharpness and bony vessel superposition, by using a five-point score each. Effective Dose (E) and data post-processing times were defined. Results: In experimental studies prescan tube current could be cut down to one-sixth of post-contrast scan doses without compromise of bone-subtraction whereas incomplete subtraction appeared from four degrees head malrotation on. Prescan E amounted to additional 1.1 mSv (+25%) in clinical studies. BS MSCTA performed significantly superior in terms of bony superposition for vascular segments C3-C7 (p < 0.001), V1-V2, V3-V4 (p < 0.05, p < 0.001 respectively) and the ophthalmic artery (p < 0.05), whereas vessel contour sharpness in BS MSCTA only proved superior for arterial segments V3-V4 (p < 0.001) and C3-C7 (p < 0.001). MBR MSCTA received higher ratings in vessel contour sharpness for C1-C2 (p < 0.001), callosomarginal artery (p < 0.001), M1, M2, M3 (p < 0.001 each) and the basilar artery (p < 0.001). Reconstruction times amounted to an average of 1.5 (BS MSCTA) and 3 min (MBR MSCTA) respectively. Conclusion: The novel BS algorithm provides superior skull base artery visualisation as compared to common manual bone removal algorithms, increasing the Effective Dose by one-fourth. Yet, inferior vessel contour sharpness was noted intracranially, thus

  9. Computer-Assisted Detection of Pulmonary Nodules: Preliminary Observations Using a Prototype System with Multidetector-Row CT Data Sets

    Lawler, Leo P.; Wood, Susan A.; Pannu, Harpreet S.; Fishman, Elliot K.

    2003-01-01

    The continued revolution in multidetector-row CT (MDCT) scanning increases the quality of lung imaging but at the cost of a greater burden of data for review and interpretation. This article discusses our preliminary experience with prototype software for lung nodule detection and characterization using MDCT data sets. We discuss the potential role of computer-assisted detection (CAD) as applied to the automatic detection of lung nodules. We also review the process of CAD, outline its potenti...

  10. Comparison of the Multidetector-row Computed Tomographic Angiography Axial and Coronal Planes' Usefulness for Detecting Thoracodorsal Artery Perforators

    Jong Gyu Kim; Soo Hyang Lee

    2012-01-01

    Background During the planning of a thoracodorsal artery perforator (TDAP) free flap, preoperative multidetector-row computed tomographic (MDCT) angiography is valuable for predicting the locations of perforators. However, CT-based perforator mapping of the thoracodorsal artery is not easy because of its small diameter. Thus, we evaluated 1-mm-thick MDCT images in multiple planes to search for reliable perforators accurately. Methods Between July 2010 and October 2011, 19 consecutive patients...

  11. Multidetector row computed tomography may accurately estimate plaque vulnerability. Does MDCT accurately estimate plaque vulnerability? (Pro)

    Over the past decade, multidetector row computed tomography (MDCT) has become the most reliable and established of the noninvasive examination techniques for detecting coronary heart disease. Now MDCT is chasing intravascular ultrasound (IVUS) in terms of spatial resolution. Among the components of vulnerable plaque, MDCT may detect lipid-rich plaque, the lipid pool, and calcified spots using computed tomography number. Plaque components are detected by MDCT with high accuracy compared with IVUS and angioscopy when assessing vulnerable plaque. The TWINS study and TOGETHAR trial demonstrated that angioscopic loss of yellow color occurred independently of volumetric plaque change by statin therapy. These 2 studies showed that plaque stabilization and regression reflect independent processes mediated by different mechanisms and time course. Noncalcified plaque and/or low-density plaque was found to be the strongest predictor of cardiac events, regardless of lesion severity, and act as a potential marker of plaque vulnerability. MDCT may be an effective tool for early triage of patients with chest pain who have a normal electrocardiogram (ECG) and cardiac enzymes in the emergency department. MDCT has the potential ability to analyze coronary plaque quantitatively and qualitatively if some problems are resolved. MDCT may become an essential tool for detecting and preventing coronary artery disease in the future. (author)

  12. Noninvasive Coronary Angiography with 64-Channel Multidetector Computed Tomography in Patients with Acute Coronary Syndrome

    Ulimoen, G. R.; Gjoennaess, E.; Atar, D.; Dahl, T.; Stranden, E.; Sandbaek, G. [Dept. of Radiology, Dept. of Vascular Diagnosis and Research, and Division of Cardiology, Aker Univ. Hospital, Oslo (Norway)

    2008-12-15

    Background: Advances in computer tomography (CT) imaging technology in recent years have facilitated the possibility of noninvasive coronary angiography. Purpose: To compare the diagnostic accuracy of 64-channel multidetector computed tomography (MDCT) with conventional invasive coronary angiography (ICA) for the detection of significant coronary stenosis in patients with acute coronary syndrome (ACS). Material and Methods: MDCT was performed in 60 patients classified with non-ST-elevation infarction (NSTEMI) or unstable angina and scheduled for ICA within 3 days. The diagnostic accuracy of MDCT was evaluated using quantitative coronary angiography (QCA) as the gold standard. Results: 48 out of 60 patients had interpretable scans by both MDCT and ICA. On a segment-based analysis, 488 out of 665 segments with a diameter of =1.5 mm, as defined by QCA, were interpretable by MDCT. Sensitivity was 78%, specificity 87%, positive predictive value 47%, and negative predictive value 97% in detecting and excluding significant coronary stenosis, as defined with MDCT. On a per patient-based analysis, sensitivity was 89%, specificity 50%, positive predictive value 84%, and negative predictive value 60%. Conclusion: Limited diagnostic accuracy restricts the usefulness of coronary MDCT in patient groups with a high pretest probability of disease, such as in acute coronary syndrome.

  13. Noninvasive Coronary Angiography with 64-Channel Multidetector Computed Tomography in Patients with Acute Coronary Syndrome

    Background: Advances in computer tomography (CT) imaging technology in recent years have facilitated the possibility of noninvasive coronary angiography. Purpose: To compare the diagnostic accuracy of 64-channel multidetector computed tomography (MDCT) with conventional invasive coronary angiography (ICA) for the detection of significant coronary stenosis in patients with acute coronary syndrome (ACS). Material and Methods: MDCT was performed in 60 patients classified with non-ST-elevation infarction (NSTEMI) or unstable angina and scheduled for ICA within 3 days. The diagnostic accuracy of MDCT was evaluated using quantitative coronary angiography (QCA) as the gold standard. Results: 48 out of 60 patients had interpretable scans by both MDCT and ICA. On a segment-based analysis, 488 out of 665 segments with a diameter of =1.5 mm, as defined by QCA, were interpretable by MDCT. Sensitivity was 78%, specificity 87%, positive predictive value 47%, and negative predictive value 97% in detecting and excluding significant coronary stenosis, as defined with MDCT. On a per patient-based analysis, sensitivity was 89%, specificity 50%, positive predictive value 84%, and negative predictive value 60%. Conclusion: Limited diagnostic accuracy restricts the usefulness of coronary MDCT in patient groups with a high pretest probability of disease, such as in acute coronary syndrome

  14. Multidetector row computed tomography may accurately estimate plaque vulnerability: does MDCT accurately estimate plaque vulnerability? (Pro).

    Komatsu, Sei; Imai, Atsuko; Kodama, Kazuhisa

    2011-01-01

    Over the past decade, multidetector row computed tomography (MDCT) has become the most reliable and established of the noninvasive examination techniques for detecting coronary heart disease. Now MDCT is chasing intravascular ultrasound (IVUS) in terms of spatial resolution. Among the components of vulnerable plaque, MDCT may detect lipid-rich plaque, the lipid pool, and calcified spots using computed tomography number. Plaque components are detected by MDCT with high accuracy compared with IVUS and angioscopy when assessing vulnerable plaque. The TWINS study and TOGETHAR trial demonstrated that angioscopic loss of yellow color occurred independently of volumetric plaque change by statin therapy. These 2 studies showed that plaque stabilization and regression reflect independent processes mediated by different mechanisms and time course. Noncalcified plaque and/or low-density plaque was found to be the strongest predictor of cardiac events, regardless of lesion severity, and act as a potential marker of plaque vulnerability. MDCT may be an effective tool for early triage of patients with chest pain who have a normal ECG and cardiac enzymes in the emergency department. MDCT has the potential ability to analyze coronary plaque quantitatively and qualitatively if some problems are resolved. MDCT may become an essential tool for detecting and preventing coronary artery disease in the future. PMID:21532180

  15. Can contrast-enhanced ultrasonography replace multidetector-computed tomography in the detection of liver metastases from colorectal cancer?

    Larsen, Lars P.S.; Rosenkilde, Mona; Christensen, Henrik;

    2007-01-01

    PURPOSE: To compare the sensitivity and specificity of contrast-enhanced ultrasonography (CEUS) and 4-slice multidetector-computed tomography (MDCT) in the detection of liver metastases in patients with colorectal cancer (CRC). MATERIALS AND METHODS: Candidates for this prospective study were 461...... consecutive patients referred to the Department of Colorectal Surgery, Aarhus University Hospital with primary or local recurrence of CRC. The patients underwent liver ultrasonography (US), CEUS, MDCT and intraoperative ultrasonography (IOUS). Fine-needle biopsy was performed on all suspicious lesions...... liver metastases in 54 patients (14.8%). Multidetector CT found significantly more metastases than CEUS in 15 (28%) of the patients (p=0.02). In a patient-by-patient analysis MDCT had a non-significantly higher sensitivity in the detection of liver metastases compared to CEUS (0.89 versus 0.80, p=0...

  16. Anatomical characteristics of myocardial bridge in patients with myocardial infarction by multi-detector computed tomography

    Recent development of multi-detector computed tomography (MDCT) has made the detection of myocardial bridge (MB) easier on the left anterior descending coronary artery (LAD). The LAD segment proximal to the MB is well known to be susceptible to atherosclerosis. Anatomical characteristics of MB on LAD in patients with myocardial infarction (MI) were examined by MDCT. Subjects were 43 MI patients who had MB in the LAD and comprised 2 groups: 14 with culprit lesions in the LAD proximal to MB (culprit group) and 29 without culprit lesions in the LAD (non-culprit group). MB length, MB thickness, and the distance from the orifice of left main trunk (LMT) to MB entrance were compared. Age and coronary risk factors showed no significant difference between the 2 groups. MB length (P=0.011), MB thickness (P=0.035), and index of the length multiplied by thickness of MB (P=0.031) were significantly greater in the culprit group. The distance from the orifice of the LMT to MB entrance was significantly shorter in the culprit group (P=0.006). Anatomical properties of MB, such as length and thickness of MB as well as MB location, are associated with the formation of culprit lesions of LAD proximal to MB in MI. (author)

  17. Right top pulmonary vein: Evaluation with 64 section multidetector computed tomography

    Purpose: To evaluate the incidence and anatomic features of the rare variant of the pulmonary veins named 'right top pulmonary vein' as depicted with 64 section multidetector computed tomography (MDCT). Materials and methods: MDCT of 610 patients obtained over 12 months period for diagnosis of suspected thoracic or cardiac pathology were routinely reviewed in transverse and 3D images. The frequency of right top pulmonary vein (RTPV) was determined and anatomic features were also documented. Results: Right top pulmonary vein (RTPV) is a supernumerary vein arising from the roof of the right part of the left atrium separately from the orifice of the right superior pulmonary vein. It crosses behind the intermediate bronchus and drains mainly posterior segment of the right upper lobe but also receives few subsegmental branches of superior segment of the right lower lobe. It was detected in 2.2% of patients (14/610). The mean diameter of RTPV was 5.1 mm. Conclusion: The RTPV is a rare venous drainage variation of pulmonary veins. It is important to be aware of this anatomic pattern for avoiding misinterpretation of pulmonary venographic findings, inadvertent ablation of pulmonary vein and perioperative bleeding during video assisted thorocoscopic lobectomy

  18. Optimization of contrast-enhanced multidetector abdominal computed tomography in sedated canine patients.

    Fields, Erica L; Robertson, Ian D; Brown, James C

    2012-01-01

    A major disadvantage of computed tomography for abdominal screening in dogs has been the need for general anesthesia to prevent motion artifacts. With multidetector helical CT, it is possible to decrease examination time, allowing patients to be scanned under sedation. It is also desirable to decrease tube loading to prolong x-ray tube life. To develop a protocol that will allow for examination of sedated patients with minimal image artifacts, milliamperage (mA) and helical pitch were varied, providing 16 experimental scan protocols. A standard clinical protocol was also tested, providing 17 protocols for evaluation. These protocols were tested, using a standard CT phantom, canine tissues in a water bath, and a canine cadaver. The cadaver images were scored semiquantitatively by three reviewers to determine the protocol with the best combination of speed and minimal image artifact. The optimized protocol was then applied to 27 sedated canine patients of three body weight categories. The images obtained were compared to the standard protocol by two reviewers for presence of motion, streak, and quantum mottle artifacts. There was significantly more streak artifact noted by one observer using the optimized study protocol, but no significant difference in any other category. Scanning under sedation was well tolerated in all patients, and sedated CT examination is a promising tool for screening abdominal disease in dogs. PMID:22612282

  19. Quantitative assessment of left ventricular systolic wall thickening using multidetector computed tomography

    Kristensen, Thomas S. [Department of Radiology, Diagnostic Centre, Rigshospitalet, University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen (Denmark)], E-mail: tskaarup@yahoo.com; Kofoed, Klaus F. [Department of Cardiology, The Heart Centre, Rigshospitalet, University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen (Denmark)], E-mail: kkofoed@dadlnet.dk; Moller, Daniel V. [Department of Cardiology, Heart Centre, Rigshospitalet, University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen (Denmark)], E-mail: DVEGA@gmx.net; Ersboll, Mads [Department of Cardiology, Heart Centre, Rigshospitalet, University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen (Denmark)], E-mail: ersboell@stud.ku.dk; Kuehl, Tobias [Department of Cardiology, The Heart Centre, Rigshospitalet, University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen (Denmark)], E-mail: tobiaskh@gmail.com; Recke, Peter von der [Department of Radiology, Diagnostic Centre, Rigshospitalet, University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen (Denmark)], E-mail: peter.von.der.recke@rh.regionh.dk; Kober, Lars [Department of Cardiology, Heart Centre, Rigshospitalet, University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen (Denmark)], E-mail: lk@heart.dk; Nielsen, Michael B. [Department of Radiology, Diagnostic Centre, Rigshospitalet, University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen (Denmark)], E-mail: mbn@dadlnet.dk; Kelbaek, Henning [Department of Cardiology, Heart Centre, Rigshospitalet, University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen (Denmark)], E-mail: henning.kelbaek@rh.regionh.dk

    2009-10-15

    Background: Multidetector computed tomography (MDCT) of the heart provides both anatomical and functional information. The objective of this study was to evaluate the accuracy of quantitative assessment of left ventricular contractile function in relation to two-dimensional transthoracic echocardiography (TTE). Materials and methods: Sixty-four patients with known or suspected coronary artery disease underwent ECG-gated 64-slice MDCT and TTE. Regional left ventricular contractile function was measured by percent systolic wall thickening (SWT) in 16 myocardial segments using MDCT, and compared with visual evaluation of wall motion score (WMS) by TTE. Global SWT by MDCT was calculated as the mean SWT of all myocardial segments and compared with wall motion index (WMI) by TTE. Results: Eight hundred and eleven segments (81%) were classified as normokinetic, 142 (14%) as hypokinetic, 41 (4%) as akinetic and 5 (0.5%) as dyskinetic by TTE. A significant inverse linear trend was found between regional SWT by MDCT and WMS by TTE (p < 0.001). Sensitivity and specificity for the identification of regional abnormalities of contractile function were 76% and 78%, respectively. A linear correlation between global SWT by MDCT and WMI by TTE was found (r = -0.8, p < 0.001). Sensitivity and specificity for the identification of WMI > 1.5 using global SWT was 91% and 94%, respectively. Conclusion: Quantification of systolic wall thickening by MDCT provides functional information, which is well correlated to visual assessment of global left ventricular contractile function by TTE.

  20. Utility of multidetector computed tomography for the hemodynamic diagnosis of esophago-gastric varices

    Diagnosis based on portal hemodynamics is essential for the clinical treatment of esophago-gastric varices; multidetector computed tomography (MDCT) is used at our institution for this purpose. Two analytic methods are used in conjunction with MDCT: volume rendering (VR) and partial maximum intensity projection (MIP). At present, the partial MIP method is more useful than the VR method, as partial MIP images clearly show the feeding and collateral veins in minute detail. Improvements in the analyzing power of MDCT have permitted the visualization of feeding veins as well as faint images of collateral veins associated with the varices. These images can be seen with a high degree of probability on MDCT images obtained using endoscopic varicerography during injection sclerotherapy. Diagnosis of the portal hemodynamics using MDCT prior to clinical treatment is likely to be an effective clinical option. However, numerous images are needed for the diagnosis of portal hemodynamics using partial MIP, and a detailed map of the portal hemodynamics is required to understand this diagnosis. Our objective is to use VR to overcome these diagnostic problems, since the use of a single image, which can be constructed within minutes, should permit the portal hemodynamics to be visualized. (author)

  1. Evaluation of hepatic arterial anatomy by multidetector computed tomographic angiography in living donor liver transplantation.

    Keles, Papatya; Yuce, Ihsan; Keles, Sait; Kantarci, Mecit

    2016-06-01

    The aim of this study was to define the different courses and percentages of hepatic artery that were detected during preoperative evaluation of living liver donors by multidetector computed tomographic angiography (MDCTA). We evaluated 150 donors before hepatic transplantation. All of the donors were evaluated by multislice CT scan with 256 detectors. For each patient, arterial, portal and venous phase images were obtained. The hepatic arterial variations were evaluated by the same radiologist according to Michels' classification. Common hepatic arterial anatomy (type I) was observed in 95 donors (63.3%). Other arterial variations were determined in the remaining 55 donors (36.6%). The second common variation was type XI which did not match with the description of Michels' classification variation in 15 donors (10%). The remaining variations described in Michels' classification were seen at lower rates. Type VII or X variation was not seen. MDCTA is a useful method to identify the blood supply of the liver before the liver transplantations, and surgeons can make their plan on the basis of CT data. PMID:26910605

  2. Advances of multidetector computed tomography in the characterization and staging of renal cell carcinoma

    Athina; C; Tsili; Maria; I; Argyropoulou

    2015-01-01

    Renal cell carcinoma(RCC) accounts for approximately 90%-95% of kidney tumors. With the widespread use of cross-sectional imaging modalities, more than half of RCCs are detected incidentally, often diagnosed at an early stage. This may allow the planning of more conservative treatment strategies. Computed tomography(CT) is considered the examination of choice for thedetection and staging of RCC. Multidetector CT(MDCT) with the improvement of spatial resolution and the ability to obtain multiphase imaging, multiplanar and threedimensional reconstructions in any desired plane brought about further improvement in the evaluation of RCC. Differentiation of RCC from benign renal tumors based on MDCT features is improved. Tumor enhancement characteristics on MDCT have been found closely to correlate with the histologic subtype of RCC, the nuclear grade and the cytogenetic characteristics of clear cell RCC. Important information, including tumor size, localization, and organ involvement, presence and extent of venous thrombus, possible invasion of adjacent organs or lymph nodes, and presence of distant metastases are provided by MDCT examination. The preoperative evaluation of patients with RCC was improved by depicting the presence or absence of renal pseudocapsule and by assessing the possible neoplastic infiltration of the perirenal fat tissue and/or renal sinus fat compartment.

  3. Multi-detector row computed tomography: Imaging in acute aortic syndrome

    Manghat, N.E. [Department of Clinical Radiology, Derriford Hospital, Plymouth, Devon (United Kingdom)]. E-mail: docnatman@msn.com; Morgan-Hughes, G.J. [Department of Cardiology, Derriford Hospital, Plymouth, Devon (United Kingdom); Roobottom, C.A. [Department of Clinical Radiology, Derriford Hospital, Plymouth, Devon (United Kingdom)

    2005-12-15

    Acute aortic syndromes (AAS) encompass a spectrum of emergencies. These include those non-traumatic disease entities of the aorta namely, penetrating atherosclerotic ulcer, intramural haematoma, dissection and aneurysm rupture. The various types of AAS cannot be reliably differentiated on clinical grounds alone. Acute thoracic aortic injury is usually included in this group even though clinical presentation is different, i.e., in the context of trauma, the imaging features are very similar. Differentiation of AAS from acute coronary syndrome (ACS) is important, however, it must be remembered that ACS may occur as a result of AAS. Now electrocardiogram (ECG)-gating technology is widely available, ECG-gated multi-detector row computed tomography (MDCT) is a powerful clinical tool in the acute emergency setting, which enables rapid and specific diagnosis of aortic pathology. ECG-gated MDCT significantly reduces motion artefact, avoids potential pitfalls in diagnosis and often provides diagnostic information about the coronary arteries. It should be used as a first-line imaging technique. This article examines the role of MDCT imaging and cardiac gating in the assessment of AAS and discusses the differentiation of this spectrum of aortic diseases with reference to the key imaging findings as obtained by experience in our institution.

  4. Multi-detector row computed tomography: Imaging in acute aortic syndrome

    Acute aortic syndromes (AAS) encompass a spectrum of emergencies. These include those non-traumatic disease entities of the aorta namely, penetrating atherosclerotic ulcer, intramural haematoma, dissection and aneurysm rupture. The various types of AAS cannot be reliably differentiated on clinical grounds alone. Acute thoracic aortic injury is usually included in this group even though clinical presentation is different, i.e., in the context of trauma, the imaging features are very similar. Differentiation of AAS from acute coronary syndrome (ACS) is important, however, it must be remembered that ACS may occur as a result of AAS. Now electrocardiogram (ECG)-gating technology is widely available, ECG-gated multi-detector row computed tomography (MDCT) is a powerful clinical tool in the acute emergency setting, which enables rapid and specific diagnosis of aortic pathology. ECG-gated MDCT significantly reduces motion artefact, avoids potential pitfalls in diagnosis and often provides diagnostic information about the coronary arteries. It should be used as a first-line imaging technique. This article examines the role of MDCT imaging and cardiac gating in the assessment of AAS and discusses the differentiation of this spectrum of aortic diseases with reference to the key imaging findings as obtained by experience in our institution

  5. To assess vascular calcification in the patients of hypoparathyroidism using multidetector computed tomography scan

    Pooja Agarwal

    2015-01-01

    Full Text Available Background: Our pilot data showed an increased intima media thickness in the patients with sporadic idiopathic hypoparathyroidism (SIH. Alteration in homeostasis of calcium, phosphate, and parathyroid hormone (PTH may predispose to increase the risk of cardiovascular morbidity and mortality. The data on objective assessment of this increased risk is however lacking. Objective: To assess the effect of altered calcium, phosphate, and PTH homeostasis in the patients with SIH on coronary calcium score (a marker of increase vascular risk by multidetector computed tomography scan (MDCT. Methods: In this case-control study, we measured coronary CT calcium score in 30 patients of SIH and compared with 40 age and sex matched healthy subjects. Correlation of coronary calcium score with biochemical parameters was evaluated. Results: Three of the 30 cases (10% with SIH were found to have coronary artery calcification (CAC of varying degree, whereas none of the control showed CAC (P = 0.07. The patients with CAC had significantly lower serum calcium levels (albumin corrected, as compared to the patients without CAC. Inverse correlation of CAC was found with serum calcium levels. No correlation was found with other biochemical parameters. Conclusion: The vascular risk is increased in the patients with SIH as assessed by coronary calcium score measured by MDCT. Low serum calcium levels might be a predisposing factor for this increased risk.

  6. Role of multidetector computed tomography in evaluation of suspected bronchogenic carcinoma

    Deepika Yadav

    2016-03-01

    Results: Patient's age ranged between 45 to 80 years with the mean age of 59 years. There was significant male preponderance (26 males with smoking being the most common risk factor (83.3%. Cough (83.3% and dyspnea (80% were the commonest symptoms. The most common radiological manifestation was central hilar mass seen in 20 (66.6% patients and peripheral mass seen in 10 (33.3% patients. Provisional CT diagnosis was found in complete correlation with pathological diagnosis made on bronchoscopy biopsy/ CT guided FNAC in 28 (93.3% patients and others 2 patients diagnosed as pulmonary tuberculosis, non caseating granulomatous inflammation on histopathological diagnosis. Squamous cell carcinoma was the commonest histopathological type seen in 16 (53.3% patients followed by adenocarcinoma seen in 8 (26.6% patients. Conclusions: Multidetector computed tomography plays an important role in evaluating and staging of bronchogenic carcinoma.CT had the high predictive value in evaluating bronchogenic carcinoma and found to be 93.3%. [Int J Res Med Sci 2016; 4(3.000: 829-835

  7. Preoperative Diagnosis of Extraglandular Invasion of Thyroid Papillary Carcinoma: High Resolution Sonography versus Multidetector Computed Tomography

    Choi, Yoon Jung; Hong, Hyun Pyo; Kwag, Hyon Joo; Kook, Shin Ho; Yun, Ji Sup; Kim, Dong Hoon [Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2009-03-15

    To compare the diagnostic efficacy of high-resolution sonography (HRS) and multidetector computed tomography (MDCT) in determining the presence of extraglandular invasion of thyroid papillary cancer and to define ultrasound (US) features of perithyroidal invasion that correlate with histopathological findings. We prospectively evaluated extracapsular invasion in 177 thyroid cancer patients using both HRS and MDCT. Receiver operating characteristics (ROC) were assessed with a four-point confidence scale (0 = no extracapsular invasion:1 = possible invasion:2 = probable invasion:3 = definite invasion) by two reviewers for each imaging modality. Sensitivity, specificity, and accuracy were analyzed for each modality, along with interobserver variability. MDCT had a mean area under the ROC curve larger than that of HRS (HRS = 0.733, MDCT = 0.807, p < 0.05). HRS and MDCT were significantly different with regard to diagnostic sensitivity, specificity, and accuracy for extrathyroidal extension (p < 0.05: HRS = 75.7%, 66.1%, and 69.8%, respectively: MDCT = 86.7%,69.7%, and 76%, respectively). Interobserver reliability was greater for MDCT than for HRS (kappa value, 0.861 versus 0.429). The cutoff value used in HRS for estimating the status of perithyroidal invasion was 2. Conclusion: HRS may be useful for preoperative investigation of thyroid papillary carcinoma extension, but it was inferior to MDCT because of lower diagnostic accuracy and lower interobserver reliability

  8. Preoperative Diagnosis of Extraglandular Invasion of Thyroid Papillary Carcinoma: High Resolution Sonography versus Multidetector Computed Tomography

    To compare the diagnostic efficacy of high-resolution sonography (HRS) and multidetector computed tomography (MDCT) in determining the presence of extraglandular invasion of thyroid papillary cancer and to define ultrasound (US) features of perithyroidal invasion that correlate with histopathological findings. We prospectively evaluated extracapsular invasion in 177 thyroid cancer patients using both HRS and MDCT. Receiver operating characteristics (ROC) were assessed with a four-point confidence scale (0 = no extracapsular invasion:1 = possible invasion:2 = probable invasion:3 = definite invasion) by two reviewers for each imaging modality. Sensitivity, specificity, and accuracy were analyzed for each modality, along with interobserver variability. MDCT had a mean area under the ROC curve larger than that of HRS (HRS = 0.733, MDCT = 0.807, p < 0.05). HRS and MDCT were significantly different with regard to diagnostic sensitivity, specificity, and accuracy for extrathyroidal extension (p < 0.05: HRS = 75.7%, 66.1%, and 69.8%, respectively: MDCT = 86.7%,69.7%, and 76%, respectively). Interobserver reliability was greater for MDCT than for HRS (kappa value, 0.861 versus 0.429). The cutoff value used in HRS for estimating the status of perithyroidal invasion was 2. Conclusion: HRS may be useful for preoperative investigation of thyroid papillary carcinoma extension, but it was inferior to MDCT because of lower diagnostic accuracy and lower interobserver reliability

  9. Comparative diagnostic performance of multidetector computed tomography and MRI for characterization of pancreatic cystic lesions

    Moon, Sung Min; Shin, Sang Soo; Park, Jin Gyoon [Dept. of Radiology, Chonnam National University Hospital, Gwangju (Korea, Republic of); Jeong, Yong Yeon [Dept. of Radiology, Chonnam National University Hwasun Hospital, Hwasun (Korea, Republic of)

    2015-06-15

    To compare the diagnostic performance of multidetector computed tomography (MDCT) and magnetic resonance imaging (MRI) in characterization of pancreatic cystic lesions. We conducted a retrospective study on 34 patients with histopathologically proven cystic pancreatic lesions who underwent both preoperative MDCT and MRI. CT and MRI were independently evaluated for differentiating mucinous vs. non-mucinous lesions, differentiating aggressive vs. non-aggressive lesion, analyzing morphological features, and evaluating specific leading diagnoses. Sensitivity, specificity, and accuracy were determined. Competency assessment of lesional morphology analysis was performed using the kappa values of the 2 tests. The sensitivity, specificity, and accuracy of MRI for differentiating mucinous vs. non-mucinous lesions were higher than CT (p = 0.03). For differentiating aggressiveness, the sensitivity of MRI was better than CT, but the specificity of CT was better than MRI. In evaluation of morphologic features, MRI showed better performance in characterization of septa and wall. Otherwise, the 2 modalities showed similarly good performance. MRI was better than CT in determining a specific diagnosis (58.8% vs. 47.2%, respectively). CT and MRI are reasonable diagnostic methods for characterization of pancreatic cystic lesions. However, MRI enables more confident assessment than CT in differentiating mucinous vs. non-mucinous lesions and characterization of the septa and wall.

  10. The role of multidetector computed tomography coronary angiography in imaging complications post-cardiac surgery

    There have been numerous advances in the field of cardiac imaging. The advent of multidetector computed tomography coronary angiography (MDCT-CA) and in particular electrocardiographic (ECG)-gated acquisition has revolutionized the investigation of the complete spectrum of complications of common cardiothoracic surgical procedures. Generic complications, such as mediastinitis, pericardial effusion, sternal osteomyelitis, and mediastinal fibrosis, are discussed with illustrative examples of multiplanar and volume-rendered three-dimensional reconstructions. Graft-related complications of both coronary artery bypass grafts and aortic root grafts are reviewed. The role of MDCT-CA in the investigation of prosthetic valve endocarditis and root abscesses is outlined. We present a complete illustration of the detailed images that are obtained when investigating a full range of graft-related complications from both aortic and coronary surgery using ECG-gated MDCT-CA. MDCT-CA has the potential to become established as the optimal technique with which to image a multitude of complications post-cardiac surgery

  11. Preoperative multidetector-row computed tomography scan staging for lymphatic gastric cancer spread

    Morgagni Paolo

    2012-09-01

    Full Text Available Abstract Background Multidetector-row computed tomography (MDCT is commonly used to stage patients with gastric cancer, even though the technique often shows low specificity for lymph-node involvement. Methods In this study, 111 patients with gastric cancer who consecutively underwent MDCT scan followed by radical surgical treatment at our hospital were retrospectively evaluated. Results In total, 3632 lymph nodes from 643 lymphatic stations were studied and then correlated with radiological features. Lymph-node size was not always associated with infiltration. Of the 261 lymph-node stations that were not radiologically detected, 60 (22.9% were infiltrated. There were 108 stations with lymph nodes larger than 10 mm seen on MDCT, of which 67 (62% had lymphatic invasion. The sensitivity was 32.6%, specificity 90.6%, positive predictive value 62.0%, negative predictive value 74.2%, and accuracy 72.1%. When three lymph nodes, at least one of which was larger than 10 mm, were detected in the same station, infiltration was confirmed with 99% specificity in 93.8% of patients. Moreover, all of the 13 patients in whom three lymph nodes larger than 10 mm were detected in different neighboring stations had lymphatic invasion. Conclusions Although presence of lymph nodes greater than 10 mm in size is not, in itself, sufficient to confirm lymphatic invasion, nodal involvement can be hypothesized when associated images are detected by MDCT.

  12. Major venous anomalies are frequently associated with horseshoe kidneys. Value of multidetector computed tomography

    Several cases of horseshoe kidney with anomalous inferior vena cava (IVC) have been described, but there have been no reports of the incidence and variation of anomalous IVC in patients with horseshoe kidneys detected using multidetector row computed tomography (MDCT). 105 patients with horseshoe kidneys were evaluated with MDCT and a variety of venous anomalies were identified in 30 patients (28.6%). Anatomical variations of the renal vein were identified in 24 patients (22.9%), which was no higher than the reported incidence in the general population. However, variations of the IVC were identified in 6 patients (5.7%), which was a higher incidence than expected to be found in the general population: 1 pre-isthmic IVC with retrocaval ureter, 2 double IVCs posterior to the horseshoe kidney, 2 left IVCs posterior to the horseshoe kidney, and 1 azygos continuation of the IVC. Horseshoe kidneys are frequently found in patients with other venous, and particularly IVC, anomalies, which should be evaluated using MDCT as part of treatment planning. (author)

  13. Imaging of peripheral arteries by 16-row multidetector computed tomography angiography: A feasible tool?

    Mishra, Anuj [Department of Radiology, National Organ Transplant Program, Tripoli (Libyan Arab Jamahiriya)]. E-mail: dranujmish@yahoo.com; Bhaktarahalli, Jahnavi Narayanaswamy [Department of Clinical Pathology, Tripoli Medical Centre, Tripoli (Libyan Arab Jamahiriya); Ehtuish, Ehtuish F. [Department of Surgery, National Organ Transplant Program, Tripoli (Libyan Arab Jamahiriya)

    2007-03-15

    Objective: To evaluate the efficacy of multidetector (16-row) computed tomography (MDCT) in imaging the upper and lower limb arterial tree in trauma and peripheral arterial occlusive disease (PAOD). Methods: Thirty-three patients underwent MDCT angiography (MDCTA) of the upper or the lower limb on 16-row MDCT scanner between November, 2004 and July, 2005. The findings were compared with the surgical outcome in cases with trauma and suspected arterial injuries or color Doppler correlation was obtained for patients of PAOD. Results: MDCTA allowed a comprehensive diagnostic work-up in all trauma cases with suspected arterial injuries. In the 23 cases of PAOD, MDCT adequately demonstrated the presence of stenosis or occlusion, its degree and extent, the presence of collaterals and plaques. Conclusion: Our experience of CT angiography (CTA) with 16-row MDCT scanner has clearly demonstrated its efficacy as a promising, new, fast, accurate, safe and non-invasive imaging modality of choice in cases of trauma with suspected arterial injuries and as a useful screening modality in cases of PAOD for diagnosis and for grading.

  14. Clinical impact of multidetector computed tomography before double-balloon enteroscopy for obscure gastrointestinal bleeding

    Hsu-Heng Yen; Yang-Yuan Chen; Chia-Wei Yang; Chi-Kuang Liu; Maw-Soan Soon

    2012-01-01

    AIM:To evaluate the clinical impact of multidetector computed tomography (MDCT) before double-balloon endoscopy (DBE) for patients with obscure gastrointestinal bleeding (OGIB).METHODS:A retrospective analysis of prospectively collected cases with DBE and MDCT for overt OGIB was conducted from April 2004 to April 2010 at Changhua Christian Hospital.We evaluated the clinical impact of MDCT on the subsequent DBE examinations and the diagnostic yields of both MDCT and DBE respectively.RESULTS:From April 2004 to April 2010,a total of 75 patients underwent DBE for overt OGIB.Thirty one cases received MDCT followed by DBE for OGIB.The overall diagnostic yields of DBE and MDCT was 93.5% and 45.2%.The MDCT had a high diagnostic yield of tumor vs non-tumor etiology of OGIB (85.7% vs 33.3%,P =0.014).Additionally,the choice of initial route of DBE was correct in those with a positive MDCT vs negative MDCT (100% vs 52.9%,P =0.003).CONCLUSION:This study suggests MDCT as a triage tool may identify patients who will benefit from DBE and aid the endoscopist in choosing the most efficient route.

  15. Enhanced multidetector-row computed tomography (MDCT) in the diagnosis of acute appendicitis and its severity

    The purpose of this study was to examine the accuracy of enhanced multidetector-row computed tomography (MDCT) in diagnosing acute appendicitis and its severity. Contrast-enhanced MD-CT 3.5 mm thick images of 23 control patients (A), and 64 patients with surgically proven acute appendicitis including 8 catarrhal (B), 28 phiegmonous (C), and 28 gangrenous (D) appendicitis patients were respectively analyzed. The number of observed major computed tomography (CT) findings for each patient group were as follows: enlarged (≥6 mm in maximum diameter) appendix (A: 5, B: 8, C: 28, D: 28), enhancement of the appendiceal wall; hyper (A: 3, B: 8, C: 27, D: 20), iso (A: 15, B: 0, C: 1, D: 2), hypo (A-C: 0, D: 4), and patched (A-C: 0, D: 2) enhancement, appendicolith (A, B: 0, C: 7, D: 13), dirty fat sign (A: 3, B: 1, C: 21, D: 28), localized ascites (A: 2, B: 0, C: 2, D: 11), and abscess formation (A-C: 0, D: 5). From the combinations of these findings, we could differentiate acute appendicitis from the control normal appendix with an accuracy of 99% and could diagnose the severity of acute appendicitis with accuracies of 92% for catarrhal appendicitis, 84% for phlegmonous appendicitis, and 92% for gangrenous appendicitis. We could also visually reconstruct the entire forms and positions of the appendices from the successive CT findings because of the high-resolution thin-slice MDCT images. MDCT is highly accurate in the diagnosis of acute appendicitis and its severity. (author)

  16. Multidetector computed tomography angiography of the celiac trunk and hepatic arterial system: normal anatomy and main variants

    Araujo-Neto, Severino Aires; Mello-Junior, Carlos Fernando de; Franca, Henrique Almeida; Duarte, Claudia Martina Araujo; Borges, Rafael Farias; Magalhaes, Ana Guardiana Ximenes de, E-mail: severinoaires@hotmail.com [Universidade Federal da Paraiba (UFPB), Joao Pessoa, PB (Brazil)

    2016-01-15

    Although digital angiography remains as the gold standard for imaging the celiac arterial trunk and hepatic arteries, multidetector computed tomography in association with digital images processing by software resources represents a useful tool particularly attractive for its non invasiveness. Knowledge of normal anatomy as well as of its variations is helpful in images interpretation and to address surgical planning on a case-by-case basis. The present essay illustrates several types of anatomical variations of celiac trunk, hepatic artery and its main branches, by means of digitally reconstructed computed tomography images, correlating their prevalence in the population with surgical implications. (author)

  17. Multidetector computed tomography angiography of the celiac trunk and hepatic arterial system: normal anatomy and main variants

    Although digital angiography remains as the gold standard for imaging the celiac arterial trunk and hepatic arteries, multidetector computed tomography in association with digital images processing by software resources represents a useful tool particularly attractive for its non invasiveness. Knowledge of normal anatomy as well as of its variations is helpful in images interpretation and to address surgical planning on a case-by-case basis. The present essay illustrates several types of anatomical variations of celiac trunk, hepatic artery and its main branches, by means of digitally reconstructed computed tomography images, correlating their prevalence in the population with surgical implications. (author)

  18. Traumatic Lumbar Artery Arteriovenous Fistula: Preclinically Detected by 16-Multidetector-Row Computed Tomography and Post-processing Techniques

    Chou, C.P.; Pan, H.B.; Wu, T.H.; Huang, F.D.; Wu, M.T. [Dept. of Radiology, Dept. of Vascular Surgery, and Dept. of Emergency, Kaohsiung Veterans General Hospital, Kaohsiung, Taiwan (China); National Yang-Ming Univ. School of Medicine, Taipei, Taiwan (China)

    2007-04-15

    We report a 21-year-old woman with a penetrating abdominal wound. Injuries of the abdominal aorta and alimentary tract were found during emergency surgery. The patient had a follow-up computed tomography (CT) scan 3 months after surgery. Arterial-phase 16-row multidetector computed tomography (MDCT) showed a suspicious dilated vessel adjacent to the repaired aorta on 5-mm transverse images. A fistula between a lumbar artery and the inferior vena cava was clearly demonstrated on images reformatted with two- (2D) and three-dimensional (3D) techniques. The patient suffered from symptoms of high-output heart failure 8 months after surgery.

  19. Mediastinite aguda: aspectos de imagem pós-cirurgias cardíacas na tomografia computadorizada de multidetectores Acute mediastinitis: multidetector computed tomography findings following cardiac surgery

    Clarissa Aguiar de Macedo

    2008-08-01

    Full Text Available Mediastinite pós-cirurgias torácicas é definida como a infecção dos órgãos e tecidos do espaço mediastinal, ocorrendo em 0,4% a 5% dos casos. A gravidade da infecção pós-operatória varia desde infecção de tecidos superficiais da parede torácica até mediastinite fulminante com envolvimento esternal. O critério diagnóstico da tomografia computadorizada para mediastinite aguda pós-cirúrgica é a presença de coleção mediastinal, podendo estar associada ou não a anormalidades periesternais como edema/borramento de partes moles, separação dos segmentos esternais com reabsorção óssea marginal, esclerose e osteomielite. Achados associados incluem linfonodomegalias, consolidações pulmonares e derrame pleural e pericárdico. Pequenas coleções e gás mediastinais podem ser usualmente encontradas em pós-operatório recente de cirurgias torácicas sem a presença de infecções, limitando a eficácia da tomografia computadorizada nas duas primeiras semanas. Após esse período, a tomografia alcança quase 100% de sensibilidade e especificidade. Pacientes com suspeita clínica de mediastinite devem ser submetidos a exame de tomografia para pesquisa de coleções, identificando a extensão da doença e sua natureza. A versão de multidetectores propicia recursos de reconstruções em diversos planos e janelas, contribuindo especialmente para o estudo do esterno.Postoperative mediastinitis is defined as an infection of the organs and tissues in the mediastinal space, with an incidence ranging between 0.4% and 5% of cases. This disease severity varies from infection of superficial tissues in the chest wall to fulminant mediastinitis with sternal involvement. Diagnostic criterion for postoperative detection of acute mediastinitis at computed tomography is the presence of fluid collections and gas in the mediastinal space, which might or might not be associated with peristernal abnormalities such as edema of soft tissues

  20. Findings of multidetector row computed tomography of HCCs treated by HIFU ablation

    Purpose: We evaluated the efficacy of high-intensity focused ultrasound (HIFU) ablation for hepatocellular carcinoma (HCC), and a long-term study by follow-up multidetector-row computed tomography (CT) was conducted to evaluate the changes occurring in the treatment area following the HIFU ablation. Materials and methods: HIFU ablation was carried out in 14 patients with small HCCs (≤3 lesions, ≤3 cm in diameter). The HIFU system (Chongqing Haifu Tech) was used under ultrasound guidance. The evaluations were performed by follow-up CT at 1 week, 1, 3, 6 and 12 months after the HIFU ablation. Results: HIFU ablation was carried out successfully in 11 of the 14 patients. At 1 week after the HIFU, a peripheral rim enhancement was found in all cases (100%). This finding was persistent in 6 of the 11 cases (54.5%) at 1 month, and in 1 of the 11 (9%) cases at 3 months after HIFU ablation. In all cases, the rim enhancement disappeared by 6 or 12 months after the HIFU ablation. At the 12 months follow-up, a decrease in the diameter of the ablated lesions was found. The enhancement around the treated area was found to be persistent at the 12 months follow-up in the one case of recurrence of the treated site in which the safety margin was not sufficiently wide. During the follow-up period, there were 2 cases with residual of HCC tumors. We performed radiofrequency ablation (RFA) for these residual tumors after the HIFU ablation. Conclusion: To ascertain the cause of the peripheral enhancement on follow-up CT images after the HIFU ablation, in particular, to determine whether it might be caused by residual tumor or recurrence at the treated site, careful follow-up is important, especially in cases where the safety margin of the ablated area was not sufficiently wide.

  1. Multidetector computed tomography mesentericography for the diagnosis of obscure gastrointestinal bleeding

    Heiss, P.; Hamer, O.W.; Mueller-Wille, R.; Rennert, J.; Feuerbach, S.; Zorger, N. [Regensburg Univ. (Germany). Inst. fuer Roentgendiagnostik; Wrede, C.E. [Helios-Klinikum Berlin-Buch (Germany). Interdisziplinaeres Notfallzentrum mit Rettungsstelle; Siebig, S.; Schoelmerich, J. [Regensburg Univ. (Germany). Medizinische Klinik und Poliklinik I

    2011-01-15

    Purpose: To evaluate the diagnostic yield of 16-row multidetector computed tomography (CT) mesentericography in patients with obscure gastrointestinal bleeding. Materials and Methods: The radiological information system database was used to retrospectively identify all patients in whom CT mesentericography (CTM) was performed for the diagnosis of obscure gastrointestinal bleeding between July 2002 and September 2006. A subsequent prospective study was conducted between October 2006 and September 2009 to evaluate CTM in patients with major obscure gastrointestinal bleeding. The retrospectively identified patients (six patients) as well as the prospectively evaluated patients (seven patients) constitute the study population. Following mesenteric DSA the catheter was left in the superior mesenteric artery, the patient was transferred to the CT suite and CTM was carried out by scanning the abdomen after contrast material injection via the catheter. Active bleeding was suspected if a focal area of high attenuation consistent with contrast material extravasation was found within the bowel lumen. Results: CTM detected the site of active bleeding in three of 13 patients (23 %). In the subpopulation of patients who were prospectively evaluated, CT mesentericography identified the site of active bleeding in one of seven patients (14 %). Depiction of active bleeding by CTM prompted surgical intervention in each case and surgery confirmed the findings of CT mesentericography. Conclusion: Due to the relatively low rate of positive findings and inherent drawbacks, we feel that CTM cannot be recommended in general. However, in selected patients who are continuously bleeding at a low rate and in whom iv-CT was negative, CT mesentericography might be helpful. (orig.)

  2. Association between carotid plaque composition assessed by multidetector computed tomography and cerebral embolism after carotid stenting

    Uchiyama, Naoyuki [Kanazawa University, Department of Neurosurgery and Radiology, Graduate School of Medical Science, Kanazawa (Japan); Kanazawa University, Department of Neurosurgery, Division of Neuroscience, Graduate School of Medical Science, Kanazawa, Ishikawa (Japan); Misaki, Kouichi; Mohri, Masanao; Watanabe, Takuya; Hirota, Yuichi; Nakada, Mitsutoshi; Hayashi, Yutaka; Ueda, Fumiaki; Hamada, Jun-ichiro [Kanazawa University, Department of Neurosurgery and Radiology, Graduate School of Medical Science, Kanazawa (Japan)

    2012-05-15

    We aimed to assess the relationship between atherosclerotic carotid plaque composition analyzed using multidetector computed tomography (MDCT) and the appearance of new ischemic lesions detected by diffusion-weighted images (DWI) after carotid artery stenting (CAS). We quantitatively and qualitatively analyzed plaque characteristics in carotid arteries using MDCT before CAS in 19 patients. Carotid plaques were expediently subdivided into four components with Hounsfield unit (HU) values of <0, 0-60, 60-130, and >600. The incidence of distal embolism was evaluated with DWI. Pearson's correlation analyses were used to assess the association between plaque composition and the incidence of cerebral embolization. Fifteen patients (79%) demonstrated new DWI lesions after CAS. High-signal DWIs were noted as follows: one in six patients, 2{proportional_to}5 in five patients, 6{proportional_to}10 in two patients, and >10 in two patients. The mean volumes of the plaque components for HU < 0, 0-60, 60-130, and >600 were 5.4, 200, 260, and 59 mm{sup 3}, respectively. There was a strong correlation between the number of high-signal DWI lesions in the ipsilateral side and the plaque volume of HU < 0 (r = 0.927; P < 0.0001). There was a moderate correlation between the number of high-signal DWI lesions and the plaque volume of HU 0-60 (r = 0.568; P = 0.0099) and the sum total of HU < 0 and HU 0-60 (r = 0.609; P = 0.0047). Quantitative and qualitative tissue characterization of carotid plaques using MDCT might be a useful predictor for silent ischemic lesions after CAS. (orig.)

  3. Epicardial adipose tissue radiodensity is independently related to coronary atherosclerosis. A multidetector computed tomography study

    Preliminary research indicates that epicardial adipose tissue (EAT) may display both anti- and proatherosclerotic properties. Because the varying radiodensities of selected human tissues assessed by multidetector computed tomography (MDCT) has been shown to reflect differences in biological characteristics, the present study investigated the hypothesis that the proatherosclerotic properties of EAT may be linked to its radiodensity. The study included 164 consecutive patients (82 females, mean age 58.8±11.1 years) with suspected coronary artery disease (CAD) undergoing MDCT coronary angiography. Coronary atherosclerosis was defined as: CAD (id est (ie), presence of at least 1 coronary stenosis ≥50%) and coronary artery calcium (CAC) determined by Agatston score. EAT radiodensity was assessed by MDCT and averaged -81.00±4.64 HU (Hounsfield unit (HU) scale). Mean CAC score was 96.0±220.0. Patients with CAD (n=36) showed higher EAT radiodensity than patients without CAD (-78.99±4.12 vs. -81.57±4.64 HU, P<0.01). In the multivariable model, only EAT radiodensity and age were independently associated with CAD (odds ratio (OR) 1.15, 95%confidence interval (CI) 1.04-1.28; OR 1.08, 95%CI 1.04-1.12; respectively). EAT radiodensity also correlated with CAC score (r=0.23, P<0.01). EAT radiodensity (P<0.001), age (P<0.001), sex (P=0.03), and past smoking (P<0.01) were independent correlates of CAC in the multivariable linear regression model. Increased EAT radiodensity is independently associated with coronary atherosclerosis, which may reflect the unfavorable, proatherosclerotic metabolic properties of more radiodense epicardial fat. (author)

  4. Multidetector computed tomography predictors of late ventricular remodeling and function after acute myocardial infarction

    Background: Despite advent of rapid arterial revascularization as 1st line treatment for acute myocardial infarction (AMI), incomplete restoral of flow at the microvascular level remains a problem and is associated with adverse prognosis, including pathological ventricular remodeling. We aimed to study the association between multidetector row computed tomography (MDCT) perfusion defects and ventricular remodeling post-AMI. Methods: In a prospective study, 20 patients with ST-elevation AMI, treated by primary angioplasty, underwent arterial and late phase MDCT as well as radionuclide scans to study presence, size and severity of myocardial perfusion defects. Contrast echocardiography was performed at baseline and at 4 months follow-up to evaluate changes in myocardial function and remodeling. Results: Early defects (ED), late defects (LD) and late enhancement (LE) were detected in 15, 7 and 16 patients, respectively and radionuclide defects in 15 patients. The ED area (r = 0.74), and LD area (r = 0.72), and to a lesser extent LE area (r = 0.62) correlated moderately well with SPECT summed rest score. By univariate analysis, follow-up end-systolic volume index and ejection fraction were both significantly related to ED and LD size and severity, but not to LE size or severity. By multivariate analysis, end-systolic volume index was best predicted by LD area (p < 0.05) and ejection fraction by LD enhancement ratio. Conclusions: LD size and severity on MDCT are most closely associated with pathological ventricular remodeling after AMI and may thus play a role in early identification and treatment of this condition

  5. The value of multidetector-row computed tomography for localization of obscure acute gastrointestinal bleeding

    Purpose: There are no simple guidelines on when to perform multidetector-row computed tomography (MDCT) for diagnosis of obscure acute gastrointestinal bleeding (AGIB). We used a risk scoring system to evaluate the diagnostic power of MDCT for patients with obscure AGIB. Materials and methods: Ninety-two patients with obscure AGIB who were referred for an MDCT scan after unsuccessful endoscopic treatment at presentation were studied. We recorded clinical data and calculated Blatchford score for each patient. Patients who required transfusion more than 500 mL of blood to maintain the vital signs were classified as high-risk patients. Two radiologists independently reviewed and categorized MDCT signs of obscure AGIB. Discordant findings were resolved by consensus. One-way ANOVA was used to compare clinical data between two groups; kappa statistics were used to estimate agreement on MDCT findings between radiologists. Results: Of the 92 patients, 62 (67.4%) were classified as high-risk patients. Blatchford scores of high-risk patients were significantly greater than those of low-risk patients. Sensitivity for MDCT diagnosing obscure AGIB was 81% in high-risk patients, as compared with 50% in the low-risk. When used in conjunction with selection of the cut-off value of 13 in Blatchford scoring system, the sensitivity and specificity of MDCT were 70.9% and 73.7%, respectively. Contrast extravasation was the most specific sign of AGIB (k = .87), recognition of which would have improved diagnostic accuracy. Conclusions: With the aid of Blatchford scoring system for evaluating the disease severity, MDCT can localize the bleeders of obscure AGIB more efficiently.

  6. Acute Knee Trauma: Analysis of Multidetector Computed Tomography Findings and Comparison with Conventional Radiography

    Mustonen, A.O.T. [Helsinki Univ. Central Hospital (Finland). Dept. of Radiology; Koskinen, S.K. [Research Inst. of Military Medicine, Helsinki (Finland); Kiuru, M.J. [ORTON Orthopaedic Hospital, Helsinki (Finland)

    2005-12-01

    Purpose: To evaluate the multidetector computed tomography (MDCT) findings of acute knee trauma and to compare radiography with MDCT in patients referred ta level 1 trauma center. Material and Methods: During a 5-year period, a total of 415 MDCT examinations were performed on 409 patients with acute knee trauma to reveal complex fracture anatomy or rule out a fracture. MDCT and primary radiographs were re-evaluated with respect to fracture location and trauma mechanism. Tibial plateau fractures were further analyzed depending on anatomical location: anterior-medial, anterior-lateral, posterior-lateral, and posterior-medial regions. Maximal depression of the tibial articular surface was measured. Findings on the primary knee radiographs were compared with MDCT findings. Results: Of the 409 patients, 356 (87%) had a knee fracture. A total of 451 fractures were found in all anatomic regions: distal femur ( n = 49), proximal tibia ( n 307), patella ( n = 23), and proximal fibula ( n = 72). Primary radiographs were available in 316 (76%) cases. Of these, 225 (71%) had MDCT in order to reveal the fracture anatomy better, and 91 (29%) had a subsequent MDCT after negative plain radiographs. Overall sensitivity of radiography was 83%, while negative predictive value was 49%. On radiography, tibial plateau articular depression was underestimated in all regions except when the fracture consisted of the whole half of the anterior or posterior plateau. The three main injury mechanisms were traffic accident, a simple fall, and sport. In 49 cases (15%), primary radiographs were suboptimal due to positioning. Conclusion: In severely injured patients, diagnostically sufficient radiographs are difficult to obtain, and therefore a negative radiograph is not reliable in ruling out a fracture. In these patients, MDCT is a fast and accurate examination and is also recommended in patients with tibial plateau fractures or complex knee injuries in order to evaluate the fracture adequately.

  7. Multidetector-row computed tomography findings of sclerosing mesenteritis with associated diseases and its prevalence

    Our aim was to report the multidetector-row computed tomography (MDCT) findings of sclerosing mesenteritis, which is a rare disease characterized by chronic nonspecific inflammation of mesenteric adipose tissue. It has associated diseases, and we explored its prevalence. A total of 2100 patients were evaluated retrospectively for sclerosing mesenteritis between December 2007 and May 2009. Signs and symptoms, associated diseases, laboratory data, surgical histories, and related findings of a misty mesentery, which corresponds to sclerosing mesenteritis on MDCT, were recorded. Misty mesentery findings were seen in 51 (2.43%; 35 men) patients. Their ages ranged between 33 and 78 years (mean 56.2 years). The most frequent complaint of patients was abdominal pain (n=19; 37.2%). The most prominent possible causative and/or associated factors in our study were malignancy (n=9; 17.6%), previous surgery (n=17; 33.3%), smoking (n=20; 39.2%), coronary artery disease (n=9; 17.6%), urolithiasis (n=10; 19.6%), hypertension (n=18; 35.2%), hyperlipidemia (n=13; 25.5%), and diabetes mellitus (n=11; 21.5%). On MDCT, density values in mesenteric fat (-62.8±18.6 Hounsfield unit (HU)) were significantly higher than the values for subcutaneous (-103.9±5.8 HU) and retroperitoneal (-105±6 HU) fatty tissues (both P<0.0001). A partially hyperdense stripe (n=37; 72.6%), well-defined soft tissue nodules (100%), hypodense fatty halo enclosing vessels (n=1; 1.9%), and nodules (n=12; 23.5%) were demonstrated in most of the patients. The diagnosis of sclerosing mesenteritis has increased with the more frequent use of MDCT and the popularization of the Digital Imaging and Communications in Medicine (DICOM) viewer. Defined hallmarks on MDCT can be helpful for differentiating sclerosing mesenteritis from other pathologies. (author)

  8. The role of multidetector computed tomography in evaluation of small bowel obstructions

    Mehmet Fatih İnci

    2013-03-01

    Full Text Available Objective: The purpose of the study was to evaluate therole and additional diagnostic contribution of multi-detectorcomputed tomography (MDCT in patients with acuteabdominal pain caused by small bowel obstruction.Materials and methods: A total of 48 patients who admittedto our hospital with acute abdominal pain and underwentMDCT on suspicion of intestinal obstruction and hadabdominal surgery between January 2012 and October2012 were included to our study. MDCT images were interpretedby two experienced radiologist retrospectively.All clinical data and surgery notes also were evaluated.Patients had surgery due to penetrating or blunt abdominalinjury were excluded.Results: Of these 48 patients, 26 (54.1% were male and22 (45.9% were female. Patients’ ages ranged 25 to 71and mean age was 52±5.4 years. The causes of intestinalobstruction of patients were adhesions for 12 (46.1% patients,tumors for 7 (26.9% patients, external hernias for5 (19.2% patients, internal hernia for 1 (3.9% patient andintussusception for 1 (3.9% patient. A total concordancebetween the MDCT findings and definitive diagnosis wasfound in 26 of 23 cases and the sensitivity and specifityof MDCT in the diagnosis of small bowel obstruction werefound to be 88.5% and 90%, respectively.Conclusion: MDCT is a fast, effective and reliable imagingmethod for preoperative diagnosing small bowel obstructioncauses acute abdominal pain with the advantagesof MDCT such as multi-planar and three-dimensionalreformatted imaging.Key words: Acute abdominal pain, multi-detector computed tomography, small bowel obstruction

  9. Diagnostic value of multidetector computed tomography for renal sinus fat invasion in renal cell carcinoma patients

    Kim, Cherry, E-mail: cherrykim0505@gmail.com; Choi, Hyuck Jae, E-mail: choihj@amc.seoul.kr; Cho, Kyoung-Sik, E-mail: kscho@amc.seoul.kr

    2014-06-15

    Objective: Although renal sinus fat invasion has prognostic significance in patients with renal cell carcinomas (RCCs), there are no previous studies about the value of multidetector computed tomography (MDCT) about this issue in the current literature. Materials and methods: A total of 863 consecutive patients (renal sinus fat invasion in 110 patients (12.7%)) from single institutions with surgically-confirmed renal cell carcinoma who underwent MDCT between 2010 and 2012 were included in this study. The area under the curves (AUCs) of the receiver operating characteristic (ROC) analysis was used to compare diagnostic performance. Reference standard was pathologic examination. Weighted κ statistics were used to measure the level of interobserver agreement. Multivariate logistic regression model was used to find the predictors for renal sinus fat invasion. Image analysis was first performed with axial-only CT images. A second analysis was then performed with both axial and coronal CT images. A qualitative analysis was then conducted by two reviewers who reached consensus regarding tumor size, decreased perfusion, tumor margin, vessel displacement, and lymph node metastasis. The reference standard was pathologic evaluation. Results: The AUCs of the ROC analysis were 0.881 and 0.922 for axial-only images and 0.889 and 0.902 for combined images in both readers. The AUC of tumor size was 0.884, a similar value to that of the reviewers. In multivariate analysis, tumor size, a linear-nodular or nodular type of fat infiltration, and an irregular tumor margin were independent predicting factors for perinephric fat invasion. Conclusion: MDCT shows relatively high diagnostic performance in detecting perinephric fat invasion of RCC but suffers from a relatively low PPV related to low prevalence of renal sinus fat invasion. Applying tumor size alone we could get similar diagnostic performance to those of radiologists. Tumor size, fat infiltration with a nodular appearance, and

  10. Multidetector computed tomography predictors of late ventricular remodeling and function after acute myocardial infarction

    Lessick, Jonathan, E-mail: j_lessick@rambam.health.gov.il [Cardiology Department, Rambam Health Care Campus, Haaliya Street, Haifa (Israel); Technion-IIT, Haaliya Street, Haifa (Israel); Abadi, Sobhi [Medical Imaging Department, Rambam Health Care Campus, Haaliya Street, Haifa (Israel); Agmon, Yoram [Cardiology Department, Rambam Health Care Campus, Haaliya Street, Haifa (Israel); Technion-IIT, Haaliya Street, Haifa (Israel); Keidar, Zohar [Nuclear Medicine Department, Rambam Health Care Campus, Haaliya Street, Haifa (Israel); Technion-IIT, Haaliya Street, Haifa (Israel); Carasso, Shemi; Aronson, Doron [Cardiology Department, Rambam Health Care Campus, Haaliya Street, Haifa (Israel); Technion-IIT, Haaliya Street, Haifa (Israel); Ghersin, Eduard [Department of Diagnostic Radiology, University of Miami, Miller School of Medicine, Miami, FL (United States); Rispler, Shmuel [Cardiology Department, Rambam Health Care Campus, Haaliya Street, Haifa (Israel); Technion-IIT, Haaliya Street, Haifa (Israel); Sebbag, Anat [Cardiology Department, Rambam Health Care Campus, Haaliya Street, Haifa (Israel); Israel, Ora [Nuclear Medicine Department, Rambam Health Care Campus, Haaliya Street, Haifa (Israel); Technion-IIT, Haaliya Street, Haifa (Israel); Hammerman, Haim; Roguin, Ariel [Cardiology Department, Rambam Health Care Campus, Haaliya Street, Haifa (Israel); Technion-IIT, Haaliya Street, Haifa (Israel)

    2012-10-15

    Background: Despite advent of rapid arterial revascularization as 1st line treatment for acute myocardial infarction (AMI), incomplete restoral of flow at the microvascular level remains a problem and is associated with adverse prognosis, including pathological ventricular remodeling. We aimed to study the association between multidetector row computed tomography (MDCT) perfusion defects and ventricular remodeling post-AMI. Methods: In a prospective study, 20 patients with ST-elevation AMI, treated by primary angioplasty, underwent arterial and late phase MDCT as well as radionuclide scans to study presence, size and severity of myocardial perfusion defects. Contrast echocardiography was performed at baseline and at 4 months follow-up to evaluate changes in myocardial function and remodeling. Results: Early defects (ED), late defects (LD) and late enhancement (LE) were detected in 15, 7 and 16 patients, respectively and radionuclide defects in 15 patients. The ED area (r = 0.74), and LD area (r = 0.72), and to a lesser extent LE area (r = 0.62) correlated moderately well with SPECT summed rest score. By univariate analysis, follow-up end-systolic volume index and ejection fraction were both significantly related to ED and LD size and severity, but not to LE size or severity. By multivariate analysis, end-systolic volume index was best predicted by LD area (p < 0.05) and ejection fraction by LD enhancement ratio. Conclusions: LD size and severity on MDCT are most closely associated with pathological ventricular remodeling after AMI and may thus play a role in early identification and treatment of this condition.

  11. Assessment of myocardial viability using multidetector computed tomography in patients with reperfused acute myocardial infarction

    Kim, T. [Department of Radiology, Ajou University School of Medicine, Suwon (Korea, Republic of); Choi, B.J. [Department of Cardiology, Ajou University School of Medicine, Suwon (Korea, Republic of); Kang, D.K., E-mail: kdklsm@ajou.ac.kr [Department of Radiology, Ajou University School of Medicine, Suwon (Korea, Republic of); Sun, J.S. [Department of Radiology, Ajou University School of Medicine, Suwon (Korea, Republic of)

    2012-08-15

    Aim: To assess the prognostic value of 64-section multidetector computed tomography (MDCT) to predict follow-up myocardial dysfunction and functional recovery after reperfusion therapy in patients with acute myocardial infarction (MI) as defined by echocardiography. Materials and methods: After reperfusion therapy for acute MI, 71 patients underwent two-phase contrast-enhanced MDCT and follow-up echocardiography. MDCT findings were compared with echocardiographic findings using kappa statistics. The areas under the receiver operating characteristic curves (AUCs) and the odds ratios (ORs) of early perfusion defects (EPD), delayed enhancement (DE), and residual perfusion defects (RPD) for predicting follow-up myocardial dysfunction and functional recovery were calculated on a segmental basis. Results: The presence of transmural EPD (EPD{sub TM}) or RPD showed good agreement (k = 0.611 and 0.658, respectively) with follow-up myocardial dysfunction, while subendocardial EPD (EPD{sub sub}) or subendocardial DE (DE{sub sub}) showed fair agreement with follow-up myocardial dysfunction (k = 0.235 and 0.234, respectively). The AUC of RPD (0.796) was superior (p < 0.001 and 0.031, respectively) to those of EPD{sub TM} (0.761) and DE{sub TM} (0.771). The presence of EPD{sub TM}, DE{sub TM}, and RPD were significant, independent positive predictors of follow-up myocardial dysfunction (OR = 6.4, 1.9, and 9.8, respectively). EPD{sub TM} was a significant, independent negative predictor of myocardial functional recovery (OR = 0.13). Conclusion: Abnormal myocardial attenuation on two-phase MDCT after reperfusion therapy may provide promising information regarding myocardial viability in patients with acute MI.

  12. Multidetector computed tomography in the evaluation of pediatric acute abdominal pain in the emergency department.

    Lin, Wei-Ching; Lin, Chien-Heng

    2016-06-01

    The accurate diagnosis of pediatric acute abdominal pain is one of the most challenging tasks in the emergency department (ED) due to its unclear clinical presentation and non-specific findings in physical examinations, laboratory data, and plain radiographs. The objective of this study was to evaluate the impact of abdominal multidetector computed tomography (MDCT) performed in the ED on pediatric patients presenting with acute abdominal pain. A retrospective chart review of children aged abdominal pain who visited the emergency department and underwent MDCT between September 2004 and June 2007 was conducted. Patients with a history of trauma were excluded. A total of 156 patients with acute abdominal pain (85 males and 71 females, age 1-17 years; mean age 10.9 ± 4.6 years) who underwent abdominal MDCT in the pediatric ED during this 3-year period were enrolled in the study. One hundred and eighteen patients with suspected appendicitis underwent abdominal MDCT. Sixty four (54.2%) of them had appendicitis, which was proven by histopathology. The sensitivity of abdominal MDCT for appendicitis was found to be 98.5% and the specificity was 84.9%. In this study, the other two common causes of nontraumatic abdominal emergencies were gastrointestinal tract (GI) infections and ovarian cysts. The most common etiology of abdominal pain in children that requires imaging with abdominal MDCT is appendicitis. MDCT has become a preferred and invaluable imaging modality in evaluating uncertain cases of pediatric acute abdominal pain in ED, in particular for suspected appendicitis, neoplasms, and gastrointestinal abnormalities. PMID:27154197

  13. Acute Knee Trauma: Analysis of Multidetector Computed Tomography Findings and Comparison with Conventional Radiography

    Purpose: To evaluate the multidetector computed tomography (MDCT) findings of acute knee trauma and to compare radiography with MDCT in patients referred ta level 1 trauma center. Material and Methods: During a 5-year period, a total of 415 MDCT examinations were performed on 409 patients with acute knee trauma to reveal complex fracture anatomy or rule out a fracture. MDCT and primary radiographs were re-evaluated with respect to fracture location and trauma mechanism. Tibial plateau fractures were further analyzed depending on anatomical location: anterior-medial, anterior-lateral, posterior-lateral, and posterior-medial regions. Maximal depression of the tibial articular surface was measured. Findings on the primary knee radiographs were compared with MDCT findings. Results: Of the 409 patients, 356 (87%) had a knee fracture. A total of 451 fractures were found in all anatomic regions: distal femur ( n = 49), proximal tibia ( n 307), patella ( n = 23), and proximal fibula ( n = 72). Primary radiographs were available in 316 (76%) cases. Of these, 225 (71%) had MDCT in order to reveal the fracture anatomy better, and 91 (29%) had a subsequent MDCT after negative plain radiographs. Overall sensitivity of radiography was 83%, while negative predictive value was 49%. On radiography, tibial plateau articular depression was underestimated in all regions except when the fracture consisted of the whole half of the anterior or posterior plateau. The three main injury mechanisms were traffic accident, a simple fall, and sport. In 49 cases (15%), primary radiographs were suboptimal due to positioning. Conclusion: In severely injured patients, diagnostically sufficient radiographs are difficult to obtain, and therefore a negative radiograph is not reliable in ruling out a fracture. In these patients, MDCT is a fast and accurate examination and is also recommended in patients with tibial plateau fractures or complex knee injuries in order to evaluate the fracture adequately

  14. Tendon entrapments and dislocations in ankle and hindfoot fractures: evaluation with multidetector computed tomography.

    Ballard, David H; Campbell, Kevin J; Blanton, Lee E; Williams, Jason T; Sangster, Guillermo; Hollister, Anne M; Simoncini, Alberto A

    2016-08-01

    The purpose of this study was to assess the incidence of tendon entrapments and tendon dislocations associated with ankle and hindfoot fractures in patients studied by multidetector computed tomography (MDCT). Additionally, we describe particular tendon injuries associated with specific fractures. This was a retrospective review of all individuals with a trauma-protocol CT for suspected ankle and/or hindfoot fractures during a consecutive 41-month time period at a single Level I Trauma Center. Each patient's images were evaluated by two radiologists and an orthopedic surgeon for tendon entrapment, tendon dislocation, and bone(s) fractured or dislocated. There were 398 patients with ankle and/or hindfoot fractures that showed tendon entrapment or dislocation in 64 (16.1 %) patients. There were 30 (46.9 %) patients with 40 tendon entrapments, 31 (48.4 %) patients with 59 tendon dislocations, and three (4.7 %) patients with both tendon entrapment and dislocation. All patients with tendon entrapments were seen with either pilon fractures and/or a combination of posterior, medial, or lateral malleolar fractures. The most frequently entrapped tendon was the posterior tibialis tendon (PTT) in 27 patients (27/30, 90.0 %). The peroneal tendons were the most frequently dislocated, representing 27 (87.1 %) of patients with tendon dislocation; all resulted from a talar or calcaneal fracture or subluxation. This study demonstrates that tendon entrapments and tendon dislocations are commonly seen in complex fractures of the ankle and hindfoot. Pilon fractures were associated with the majority of tendon entrapments, whereas calcaneus fractures were associated with the majority of tendon dislocations. PMID:27234977

  15. Diagnostic value of multidetector computed tomography for renal sinus fat invasion in renal cell carcinoma patients

    Objective: Although renal sinus fat invasion has prognostic significance in patients with renal cell carcinomas (RCCs), there are no previous studies about the value of multidetector computed tomography (MDCT) about this issue in the current literature. Materials and methods: A total of 863 consecutive patients (renal sinus fat invasion in 110 patients (12.7%)) from single institutions with surgically-confirmed renal cell carcinoma who underwent MDCT between 2010 and 2012 were included in this study. The area under the curves (AUCs) of the receiver operating characteristic (ROC) analysis was used to compare diagnostic performance. Reference standard was pathologic examination. Weighted κ statistics were used to measure the level of interobserver agreement. Multivariate logistic regression model was used to find the predictors for renal sinus fat invasion. Image analysis was first performed with axial-only CT images. A second analysis was then performed with both axial and coronal CT images. A qualitative analysis was then conducted by two reviewers who reached consensus regarding tumor size, decreased perfusion, tumor margin, vessel displacement, and lymph node metastasis. The reference standard was pathologic evaluation. Results: The AUCs of the ROC analysis were 0.881 and 0.922 for axial-only images and 0.889 and 0.902 for combined images in both readers. The AUC of tumor size was 0.884, a similar value to that of the reviewers. In multivariate analysis, tumor size, a linear-nodular or nodular type of fat infiltration, and an irregular tumor margin were independent predicting factors for perinephric fat invasion. Conclusion: MDCT shows relatively high diagnostic performance in detecting perinephric fat invasion of RCC but suffers from a relatively low PPV related to low prevalence of renal sinus fat invasion. Applying tumor size alone we could get similar diagnostic performance to those of radiologists. Tumor size, fat infiltration with a nodular appearance, and

  16. Multidetector computed tomography mesentericography for the diagnosis of obscure gastrointestinal bleeding

    Purpose: To evaluate the diagnostic yield of 16-row multidetector computed tomography (CT) mesentericography in patients with obscure gastrointestinal bleeding. Materials and Methods: The radiological information system database was used to retrospectively identify all patients in whom CT mesentericography (CTM) was performed for the diagnosis of obscure gastrointestinal bleeding between July 2002 and September 2006. A subsequent prospective study was conducted between October 2006 and September 2009 to evaluate CTM in patients with major obscure gastrointestinal bleeding. The retrospectively identified patients (six patients) as well as the prospectively evaluated patients (seven patients) constitute the study population. Following mesenteric DSA the catheter was left in the superior mesenteric artery, the patient was transferred to the CT suite and CTM was carried out by scanning the abdomen after contrast material injection via the catheter. Active bleeding was suspected if a focal area of high attenuation consistent with contrast material extravasation was found within the bowel lumen. Results: CTM detected the site of active bleeding in three of 13 patients (23 %). In the subpopulation of patients who were prospectively evaluated, CT mesentericography identified the site of active bleeding in one of seven patients (14 %). Depiction of active bleeding by CTM prompted surgical intervention in each case and surgery confirmed the findings of CT mesentericography. Conclusion: Due to the relatively low rate of positive findings and inherent drawbacks, we feel that CTM cannot be recommended in general. However, in selected patients who are continuously bleeding at a low rate and in whom iv-CT was negative, CT mesentericography might be helpful. (orig.)

  17. Method for Automatic Tube Current Selection for Obtaining a Consistent Image Quality and Dose Optimization in a Cardiac Multidetector CT

    Qi, Weiwei; Li, Jianying; Du, Xiangke

    2009-01-01

    Objective To evaluate a quantitative method for individually adjusting the tube current to obtain images with consistent noise in electrocardiogram (ECG)-gated CT cardiac scans. Materials and Methods The image noise from timing bolus and cardiac CT scans of 80 patients (Group A) who underwent a 64-row multidetector (MD) CT cardiac examination with patient-independent scan parameters were analyzed. A formula was established using the noise correlation between the timing bolus and cardiac scans...

  18. Differentiation between tuberculosis and leukemia in abdominal and pelvic lymph nodes: evaluation with contrast-enhanced multidetector computed tomography

    Ge Zhang

    2015-03-01

    Full Text Available PURPOSE: To compare the characteristics of tubercular vs. leukemic involvement of abdominopelvic lymph nodes using multidetector computed tomography (CT. MATERIALS AND METHODS: We retrospectively reviewed multidetector computed tomography features including lymph node size, shape, enhancement patterns, and anatomical distribution, in 106 consecutive patients with newly diagnosed, untreated tuberculosis (55 patients; 52% or leukemia (51 patients; 48%. In patients with leukemia, 32 (62.7% had chronic lymphocytic leukemia, and 19 (37.3% had acute leukemias; of these, 10 (19.6% had acute myeloid leukemia, and 9 (17.6% had acute lymphocytic leukemia. RESULTS: The lower para-aortic (30.9% for tuberculosis, 63.2% for acute leukemias and 87.5% for chronic lymphocytic leukemia and inguinal (9.1% for tuberculosis, 57.9% for acute leukemias and 53.1% for chronic lymphocytic leukemia lymph nodes were involved more frequently in the three types of leukemia than in tuberculosis (both with p <0.017. Tuberculosis showed peripheral enhancement, frequently with a multilocular appearance, in 43 (78.2% patients, whereas patients with leukemia (78.9% for acute myeloid leukemia and acute lymphocytic leukemia, 87.5% for chronic lymphocytic leukemia demonstrated predominantly homogeneous enhancement (both with p <0.017. For the diagnosis of tuberculosis, the analysis showed that a peripheral enhancement pattern had a sensitivity of 78.2%, a specificity of 100%, and an accuracy of 88.7%. For the diagnosis of leukemia, the analysis showed that a homogeneous enhancement pattern was associated with a sensitivity of 84.3%, a specificity of 94.5%, and an accuracy of 89.6%. CONCLUSION: Our findings indicate that the anatomical distribution and enhancement patterns of lymphadenopathy seen on multidetector computed tomography are useful for differentiating between untreated tuberculosis and leukemia of the abdominopelvic lymph nodes.

  19. Measurements of pericardial adipose tissue using contrast enhanced cardiac multidetector computed tomography—comparison with cardiac magnetic resonance imaging

    Elming, Marie Bayer; Lønborg, Jacob; Rasmussen, Thomas;

    2013-01-01

    Recent studies have suggested that pericardial adipose tissue (PAT) located in close vicinity to the epicardial coronary arteries may play a role in the development of coronary artery disease. PAT has primarily been measured with cardiac magnetic resonance imaging (CMRI) or with non......-contrast cardiac multidetector computered tomography (MDCT) images. The aim of this study was to validate contrast MDCT derived measures of total PAT volume by a comparison to CMRI. In 52 patients, aged 60 years (34-81 years), Body Mass Index 28 kg/m(2) (18-39), and with stable ischemic heart disease, paired MDCT...

  20. Intensive-care unit lung infections: The role of imaging with special emphasis on multi-detector row computed tomography

    Romano, Luigia; Pinto, Antonio; Merola, Stefanella; Gagliardi, Nicola; Tortora, Giovanni [Department of Diagnostic Imaging, Cardarelli Hospital, Naples Italy-Via G. Merliani 31, 80127 Naples (Italy); Scaglione, Mariano [Department of Diagnostic Imaging, Cardarelli Hospital, Naples Italy-Via G. Merliani 31, 80127 Naples (Italy)], E-mail: mscaglione@tiscali.it

    2008-03-15

    Nosocomial pneumonia is the most frequent hospital-acquired infection. In mechanically ventilated patients admitted to an intensive-care unit as many as 7-41% may develop pneumonia. The role of imaging is to identify the presence, location and extent of pulmonary infection and the presence of complications. However, the poor resolution of bedside plain film frequently limits the value of radiography as an accurate diagnostic tool. To date, multi-detector row computed tomography with its excellent contrast resolution is the most sensitive modality for evaluating lung parenchyma infections.

  1. Intensive-care unit lung infections: The role of imaging with special emphasis on multi-detector row computed tomography

    Nosocomial pneumonia is the most frequent hospital-acquired infection. In mechanically ventilated patients admitted to an intensive-care unit as many as 7-41% may develop pneumonia. The role of imaging is to identify the presence, location and extent of pulmonary infection and the presence of complications. However, the poor resolution of bedside plain film frequently limits the value of radiography as an accurate diagnostic tool. To date, multi-detector row computed tomography with its excellent contrast resolution is the most sensitive modality for evaluating lung parenchyma infections

  2. The Measurement of Opening Angle and Orifice Area of a Bileaflet Mechanical Valve Using Multidetector Computed Tomography

    Lee, Dong-Hyeon; Youn, Ho-Joong; Shim, Sung-Bo; Lee, Sun-Hee; Jung, Jung-Im; Jung, Seung-Eun; Choi, Yun-Seok; Park, Chul-Soo; Oh, Yong-Seog; Chung, Wook-Sung; Kim, Jae-Hyung

    2009-01-01

    Background and Objectives The aim of this study was to assess mechanical valve function using 64-slice multidetector computed tomography (MDCT). Subjects and Methods In 20 patients (mean age, 50±12 years; male-to-female ratio, 10:10), 30 St. Jude bileaflet mechanical valves (15 aortic and 15 mitral valves) were evaluated using MDCT. We selected images vertical and parallel to the mechanical valve. The valve orifice area (OA) and valve length were determined by manual tracing and the opening a...

  3. Anatomical variation of thyroid veins on contrast-enhanced multi-detector row computed tomography

    Highlights: • This is the first study to demonstrate the anatomy of thyroid veins on contrasted-enhanced MDCT. • Identifying the thyroid vein on MDCT prior to selective venous sampling of parathyroid hormone provides clinical information to interventional radiologist. • Detecting especially the inferior thyroid veins with individual variability in numbers, locations, and lengths may have an effect on SVS for HPT and decrease the difficulty and time of the procedure. - Abstract: Objective: The objective of this study was to clarify the anatomical variation of thyroid veins into the systemic vein using contrast-enhanced multi-detector row computed tomography (MDCT). Design and methods: : The subjects were 80 patients (34 males and 46 females; mean age, 50.1 years; age range, 15–92 years) with neck diseases who underwent MDCT. The number and location of inflow points of the thyroid veins into the systemic vein, and the length from the junction of bilateral brachiocephalic veins to the orifice of inferior thyroid vein were investigated by reviewing the axial and coronal images. Results: All superior thyroid veins were detected. Right and left middle thyroid veins were identified in 39 and 29 patients, respectively. Right inferior thyroid veins, left inferior thyroid veins, and common trunks were detected in 43, 46, and 39 patients, respectively; in five patients, two left thyroid veins were identified. All left inferior thyroid veins and 34 common trunks flowed into the innominate vein, while right ones had some variations in inflow sites. Mean lengths were 3.01 ± 1.30 cm (range, 0.5–6.19) and 2.04 ± 0.91 cm (0.5–4.4) in the left inferior thyroid vein and common trunk, and 1.96 ± 1.05 cm (0.81–4.8) and 1.65 ± 0.69 cm (0.63–2.94) in the right one flowing into the right internal jugular vein and the innominate vein, respectively. Conclusions: The numbers and orifices of thyroid veins were identified at high rates on contrast-enhanced MDCT. This

  4. Rectal cancer staging: Multidetector-row computed tomography diagnostic accuracy in assessment of mesorectal fascia invasion

    Ippolito, Davide; Drago, Silvia Girolama; Franzesi, Cammillo Talei; Fior, Davide; Sironi, Sandro

    2016-01-01

    AIM: To assess the diagnostic accuracy of multidetector-row computed tomography (MDCT) as compared with conventional magnetic resonance imaging (MRI), in identifying mesorectal fascia (MRF) invasion in rectal cancer patients. METHODS: Ninety-one patients with biopsy proven rectal adenocarcinoma referred for thoracic and abdominal CT staging were enrolled in this study. The contrast-enhanced MDCT scans were performed on a 256 row scanner (ICT, Philips) with the following acquisition parameters: tube voltage 120 KV, tube current 150-300 mAs. Imaging data were reviewed as axial and as multiplanar reconstructions (MPRs) images along the rectal tumor axis. MRI study, performed on 1.5 T with dedicated phased array multicoil, included multiplanar T2 and axial T1 sequences and diffusion weighted images (DWI). Axial and MPR CT images independently were compared to MRI and MRF involvement was determined. Diagnostic accuracy of both modalities was compared and statistically analyzed. RESULTS: According to MRI, the MRF was involved in 51 patients and not involved in 40 patients. DWI allowed to recognize the tumor as a focal mass with high signal intensity on high b-value images, compared with the signal of the normal adjacent rectal wall or with the lower tissue signal intensity background. The number of patients correctly staged by the native axial CT images was 71 out of 91 (41 with involved MRF; 30 with not involved MRF), while by using the MPR 80 patients were correctly staged (45 with involved MRF; 35 with not involved MRF). Local tumor staging suggested by MDCT agreed with those of MRI, obtaining for CT axial images sensitivity and specificity of 80.4% and 75%, positive predictive value (PPV) 80.4%, negative predictive value (NPV) 75% and accuracy 78%; while performing MPR the sensitivity and specificity increased to 88% and 87.5%, PPV was 90%, NPV 85.36% and accuracy 88%. MPR images showed higher diagnostic accuracy, in terms of MRF involvement, than native axial images

  5. Anatomical variation of thyroid veins on contrast-enhanced multi-detector row computed tomography

    Tomita, Hayato, E-mail: m04149@yahoo.co.jp [Department of Radiology, St. Marianna University School of Medicine, Yokohama City Seibu Hospital, 1197-1 Yasashicho, Asahi-ku, Yokohama, Kanagawa 241-0811 (Japan); Yamada, Takayuki; Murakami, Kenji; Hashimoto, Kazuki; Tazawa, Yoko; Kumano, Reiko [Department of Radiology, St. Marianna University School of Medicine, Yokohama City Seibu Hospital, 1197-1 Yasashicho, Asahi-ku, Yokohama, Kanagawa 241-0811 (Japan); Nakajima, Yasuo [Department of Radiology, St. Marianna University School of Medicine, 2-16-1 Sugao, Miyamae-ku, Kawasaki, Kanagawa 216-8511 (Japan)

    2015-05-15

    Highlights: • This is the first study to demonstrate the anatomy of thyroid veins on contrasted-enhanced MDCT. • Identifying the thyroid vein on MDCT prior to selective venous sampling of parathyroid hormone provides clinical information to interventional radiologist. • Detecting especially the inferior thyroid veins with individual variability in numbers, locations, and lengths may have an effect on SVS for HPT and decrease the difficulty and time of the procedure. - Abstract: Objective: The objective of this study was to clarify the anatomical variation of thyroid veins into the systemic vein using contrast-enhanced multi-detector row computed tomography (MDCT). Design and methods: : The subjects were 80 patients (34 males and 46 females; mean age, 50.1 years; age range, 15–92 years) with neck diseases who underwent MDCT. The number and location of inflow points of the thyroid veins into the systemic vein, and the length from the junction of bilateral brachiocephalic veins to the orifice of inferior thyroid vein were investigated by reviewing the axial and coronal images. Results: All superior thyroid veins were detected. Right and left middle thyroid veins were identified in 39 and 29 patients, respectively. Right inferior thyroid veins, left inferior thyroid veins, and common trunks were detected in 43, 46, and 39 patients, respectively; in five patients, two left thyroid veins were identified. All left inferior thyroid veins and 34 common trunks flowed into the innominate vein, while right ones had some variations in inflow sites. Mean lengths were 3.01 ± 1.30 cm (range, 0.5–6.19) and 2.04 ± 0.91 cm (0.5–4.4) in the left inferior thyroid vein and common trunk, and 1.96 ± 1.05 cm (0.81–4.8) and 1.65 ± 0.69 cm (0.63–2.94) in the right one flowing into the right internal jugular vein and the innominate vein, respectively. Conclusions: The numbers and orifices of thyroid veins were identified at high rates on contrast-enhanced MDCT. This

  6. Multidetector-row spiral computed tomography in chest emergencies; MSCT bei thorakalen Notfaellen

    Wildberger, J.E.; Leiner, T. [Maastricht University Medical Center (MUMC) (Netherlands). Department of Radiology; Mahnken, A.H. [Universitaetsklinikum Aachen (Germany). Klinik fuer Radiologische Diagnostik; RWTH Aachen (Germany). Angewandte Medizintechnik, Helmholtz-Institut fuer Biomedizinische Technik

    2009-06-15

    With ongoing advances in multidetector-row computed tomography (MDCT) using ECG gating, differentiated examination protocols have become technically feasible. For acute chest pain assessment a strict triage of patients is indispensable, as the radiation dose is approximately 3 times higher for a dedicated protocol compared to a standard chest MDCT. Clinical requests considering pathologies of the pulmonary arteries, the aortic arch and the descending aorta can safely be answered with a standard CT data set. However, for the coronary arteries as well as for the ascending aorta, ECG synchronization of the data set is required. Initial reports regarding MDCT assessment for acute chest pain report a high negative predictive value. With the latest MDCT platforms available, medical preparation is no longer necessary with the exception of sublingual application of nitroglycerine. Dedicated contrast injection protocols, however, are necessary for simultaneous opacification of the pulmonary arteries as well as of the aorta and the coronary arteries. Further prospective studies will have to provide more evidence-based data for acute chest pain assessment with MDCT and will also have to outline the cost-effectiveness of this imaging technique. (orig.) [German] Die Weiterentwicklung der Mehrschichtspiralcomputertomographie (MSCT) mit EKG-Synchronisation ermoeglicht differenzierte Untersuchungsprotokolle zur Abklaerung unklarer thorakaler Schmerzereignisse, erfordert jedoch aufgrund der gegenueber einer herkoemmlichen CT des Thorax ca. 3-fach hoeheren Strahlenexposition eine enge Indikationsstellung. Fragestellungen, die isoliert die Lungengefaesse, den Aortenbogen bzw. die deszendierende Aorta betreffen, koennen meist bereits mit einem Standard-CT-Datensatz beantwortet werden, fuer Pathologien der Aorta ascendens und zum Ausschluss einer koronaren Herzerkrankung (KHK) ist eine Submillimeterkollimation mit EKG-Synchronisation hingegen unerlaesslich. Erste Studienergebnisse

  7. Multidetector-row computed tomography for the preoperative evaluation of axillary nodal status in patients with breast cancer

    We evaluated the effectiveness of multidetector-row computed tomography (MD-CT) for detecting axillary lymph nodal status (ALNS) in patients with breast cancer. We reviewed 42 patients with breast cancer. A metastatic lymph node on MD-CT was defined as oval or round, with more than 5 mm on the short axis. We evaluated ALNS preoperatively by both palpation and MD-CT findings and performed sentinel lymph node biopsy (SLNB) and complete axillary lymph node dissection (ALND). For establishing the ALNS, MD-CT showed a sensitivity of 76.9%, a specificity of 96.6%, and an accuracy of 90.5%. On the basis of the MD-CT findings, misdiagnosis was made in 4 of the 42 patients, only one of which was false positive. On the other hand, one patient with a histologically negative sentinel lymph node (SLN) result had metastasis only in a non-SLN. Preoperative MD-CT showed a positive node in this patient. Multidetector-row computed tomography assists in identifying women who require ALND without SLNB, with sufficient positive predictive value. False-negative detection by SLNB could be avoided with careful interpretation of the axillary lymph nodes shown by MD-CT. (author)

  8. Comparison of the radiation dose from cone beam computed tomography and multidetector computed tomography in examinations of the hand

    Comparison of radiation dose of cone beam computed tomography (CBCT) and multidetector computed tomography (MDCT) in examinations of the hand. Dose calculations were carried out by means of Monte Carlo simulations in MDCT and CBCT. A corpse hand was examined in a 320-row MDCT scanner and a dedicated extremities CBCT scanner with standard protocols and multiple low-dose protocols. The image quality of the examinations was evaluated by 5 investigators using a Likert scale from 1 (very good) to 5 (very poor) regarding depiction of cortical bone, cancellous bone, joint surfaces, soft tissues and artifacts. For a sum of ratings of all structures < 50 a good overall image quality was expected. The studies with at least good overall image quality were compared with respect to the dose. The dose of the standard examination was 13.21 (12.96 to 13.46 CI) mGy in MDCT and 7.15 (6.99 to 7.30 CI) mGy in CBCT. The lowest dose in a study with good overall image quality was 4.54 (4.43 to 4.64 CI) mGy in MDCT and 5.72 (5.59 to 5.85 CI) mGy in CBCT. Although the dose of the standard protocols in the CBCT is lower than in the MDCT, the MDCT can realize a good overall image quality at a lower dose than the CBCT. Dose optimization of CT examination protocols for the hand is useful in both modalities, the MDCT has an even greater potential for optimization.

  9. The influence of heart rate, slice thickness, and calcification density on calcium scores using 64-slice multidetector computed tomography - A systematic phantom study

    Groen, Jaap M.; Greuter, Marcel J.; Schmidt, Bernhard; Suess, Christoph; Vliegenthart, Rozemarijn; Oudkerk, Matthis

    2007-01-01

    Objective: The purpose of this study was to investigate the influence of heart rate, slice thickness, and calcification density on absolute value and variability of calcium score using 64-slice multidetector computed tomography (MDCT). Methods and Materials: Three artificial arteries containing each

  10. Value of cardiac 320-multidetector computed tomography and cardiac magnetic resonance imaging for assessment of myocardial perfusion defects in patients with known chronic ischemic heart disease

    Qayyum, Abbas Ali; Kühl, Jørgen T; Mathiasen, Anders B;

    2013-01-01

    The challenge for therapies targeting perfusion abnormalities is to identify and evaluate the region of interest. The aim of this study was to compare rest and stress myocardial perfusion measured by cardiac multi-detector computed tomography (MDCT) and cardiac magnetic resonance (CMR) imaging in...

  11. A model for temporal resolution of multidetector computed tomography of coronary arteries in relation to rotation time, heart rate and reconstruction algorithm

    Greuter, M. J. W.; Flohr, T.; van Ooijen, P. M. A.; Oudkerk, M.

    2007-01-01

    A model is presented that describes the image quality of coronary arteries with multidetector computer tomography. The results are discussed in the context of rotation time of the scanner, heart rate, and number of sectors used in the acquisition process. The blurring of the coronary arteries was ca

  12. The multidetector computed tomography angiography (MDCTA) in the diagnosis of splenic artery aneurysm and pseudoaneurysm

    Saba, Luca; Mallarini, Giorgio (Dept. of Radiology, Azienda Ospedaliero Universitaria (AOU), Cagliari (Italy)), email: lucasaba@tiscali.it; Anzidei, Michele; Lucatelli, Pierleone (Dept. of Radiological Sciences, Univ. of Rome La Sapienza, Rome (Italy))

    2011-06-15

    Splenic artery aneurysm is the most frequent visceral artery aneurysm and rupture of the aneurysm is associated with a high mortality rate. It is important to discriminate between a true aneurysm and a pseudoaneurysm that may be caused by pancreatitis, iatrogenic and postoperative causes, trauma and peptic ulcer disease. Multidetector-row CT angiography (MDCTA) allows detailed visualization of the vascular anatomy and may allow identification of aneurysms and pseudoaneurysms that affect the splenic artery. The objective of this article is to provide a review of the general characteristics of splenic artery aneurysms and pseudoaneurysms and to describe the findings of MDCTA

  13. Mapping epicardial fat with multi-detector computed tomography to facilitate percutaneous transepicardial arrhythmia ablation

    A sizable portion of ventricular tachycardia circuits are epicardial, especially in patients with non-ischemic cardiomyopathy, e.g. Chagas disease. Thus there is a growing interest among the electrophysiologists in transepicardial mapping and myocardial ablation for treatment of arrhythmias. However, increased epicardial fat can be a significant hindrance in procedural success as it can mimic infarct during mapping and can also decrease the effectiveness of ablation. Quantitative knowledge of epicardial fat pre-procedure can potentially significantly facilitate the conduct and outcomes of these procedures. In this study we assessed the epicardial fat distribution and thickness in vivo in 59 patients who underwent multi-detector computed tomography (MDCT) for coronary artery assessment using a 16-slice scanner. Multiplanar reconstructions were obtained in the ventricular short axis at the basal, mid ventricular, and near the apex level, and in a four-chamber view. In the short axis slices, we measured epicardial fat diameter in nine segments, and in the four-chamber view, it was measured in five segments. In grooved segments the maximum fat thickness was recorded, while in non-grooved segments thickness at three equally spaced points were averaged. The results were as follows starting clockwise: superior inter-ventricular (IV) groove (all measurements are in mm, in basal, mid ventricular, and apical levels, respectively) (11.2, 8.6, 7.3), left ventricular (LV) superior lateral wall (1.0, 1.5, 1.7), LV inferior lateral wall (1.3, 2.2, 3.5), inferior IV groove (9.2, 6.5, 6.1), right ventricular (RV) diaphragmatic wall (1.4, 0.2, 1.0), acute margin (9.2, 7.3, 7.8), RV anterior free wall inferior (6.8, 4.0, 4.7), RV anterior free wall superior (6.5, 3.2, 3.1), RV superior wall (5.6, 2.7, 4.0), We measured the following four-chamber segments: LV apex (2.8 mm), left atrio-ventricular (AV) groove (12.7), right AV groove (14.8), RV apex (4.8), and anterior IV groove (7

  14. Computer-aided detection of small pulmonary nodules in multidetector spiral computed tomography (MSCT) in children

    Purpose: Retrospective evaluation of computer-aided detection software (CAD) for automated detection (LungCAD, Siemens Medical solutions, Forchheim, Germany) and volumetry (LungCARE) of pulmonary nodules in dose-reduced pediatric MDCT. Materials and Methods: 30 scans of 24 children (10.4±5.9 years, 13 girls, 11 boys, 39.7±29.3 kg body weight) were performed on a 16-MDCT for tumor staging (n=18), inflammation (n=9), other indications (n=3). Tube voltage 120 kVp and effective mAs were adapted to body weight. Slice thickness 2 mm, increment 1 mm. A pediatric radiologist (U1), a CAD expert (U2) and an inexperienced radiologist (U3) independently analyzed the lung window images without and with the CAD as a second reader. In a consensus decision U1 and U2 were the reference standard. Results: Five examinations had to be excluded from the study due to other underlying lung disease. A total of 24 pulmonary nodules were found in all data sets with a minimal diameter of 0.35 mm to 3.81 mm (mean 1.7±0.85 mm). The sensitivities were as follows: U1 95.8% and 100% with CAD; U2 91.7% U3 66.7%. U2 and U3 did not detect further nodules with CAD. The sensitivity of CAD alone was 41.7% with 0.32 false-positive findings per examination. Interobserver agreement between U1/U2 regarding nodule detection with CAD was good (k=0.6500) and without CAD very good (k=0.8727). For the rest (U1/U3; U2/U3 with and without CAD), it was weak (k=0.0667-0.1884). Depending on the measured value (axial measurement, volume), there is a significant correlation (p=0.0026-0.0432) between nodule size and CAD detection. Undetected pulmonary nodules (mean 1.35 mm; range 0.35-2.61 mm) were smaller than the detected ones (mean 2.19 mm; range 1.35-3.81 mm). No significant correlation was found between CAD findings and patient age (p=0.9263) and body weight (p=0.9271) as well as nodule location (subpleural, intraparenchymal; p=1.0) and noise/SNR. (orig.)

  15. Validation of a paediatric thyroid phantom using different multidetector computed tomography models

    Alsabbagh, M.; Ng, L. Y.; Tajuddin, A. A.; Manap, M. A.; Zainon, R.

    2016-03-01

    The aim of this study was to compare the attenuation values of a fabricated paediatric thyroid phantom material using different MDCT models. A paediatric thyroid phantom was designed to mimic the shape and size of a paediatric patient with an age of 9 years using high- density Polyethylene as the phantom material. The fabricated phantom was scanned using two different multidetector CT scanners (16- and 128-row detectors). The CT numbers were evaluated and the mass attenuation coefficients (μ/ρ) of the phantom material were obtained at each applied energy from each scanner. The results were compared with the tables of the National Institute of Standards and Technology (NIST). The CTs of 16- and 128-row detectors showed that the obtained attenuation values are very similar to the NIST's values. However, the CT of the 128-row detectors showed a slightly much closer match to the NIST's values. This refers to the type and quality of the electronic connections between the detectors. Furthermore, the type and number of detectors (16- and 128-detectors) could affect the details and quality of the output images. The results show that different multidetector CTs can be used to validate the phantom and determine the mass attenuation coefficients of its material.

  16. Low-fat Angiomyolipoma of the Liver Studied with Contrast-Enhanced Ultrasound and Multidetector Computed Tomography

    We report the case of a 30-year-old woman with persistent pain at the right hypochondrium, relapsing fever, and normal serum tests. Ultrasound showed a hyperechoic inhomogeneous mass; following sulfur hexafluoride injection, uniform enhancement at 14-16 s and rapid wash-out at 26 s was found. Multidetector computed tomography showed an inhomogeneously hypodense mass, with no detectable negative density values, characterized by inhomogeneous enhancement at the arterial phase and wash-out at the portal phase. Histopathology demonstrated a hepithelioid angiomyolipoma with a poor fatty component. This diagnosis should always be considered in the presence of a very rapid wash-out after intravenous contrast injection. However, a hepatocellular carcinoma cannot be excluded and the final diagnosis of low-fat angiomyolipoma must be pathologically proved based on immunohistochemistry

  17. Congenital varitans and anomalies of the pancreas and pancreatic duct: Imaging by magnetic resonance cholangiopancreaticography and multidetector computed tomography

    Though congenital anomalies of the pancreas and pancreatic duct are relatively uncommon and they are often discovered as an incidental finding in asymptomatic patients, some of these anomalies may lead to various clinical symptoms such as recurrent abdominal pain, nausea and vomiting. Recognition of these anomalies is important because these anomalies may be a surgically correctable cause of recurrent pancreatitis or the cause of gastric outlet obstruction. An awareness of these anomalies may help in surgical planning and prevent inadvertent ductal injury. The purpose of this article is to review normal pancreatic embryology, the appearance of ductal anatomic variants and developmental anomalies of the pancreas, with emphasis on magnetic resonance cholangiopancreaticography and multidetector computed tomography.

  18. Tomosynthesis for the early detection of pulmonary emphysema: diagnostic performance compared with chest radiography, using multidetector computed tomography as reference

    To compare the diagnostic performance of tomosynthesis with that of chest radiography for the detection of pulmonary emphysema, using multidetector computed tomography (MDCT) as reference. Forty-eight patients with and 63 without pulmonary emphysema underwent chest MDCT, tomosynthesis and radiography on the same day. Two blinded radiologists independently evaluated the tomosynthesis images and radiographs for the presence of pulmonary emphysema. Axial and coronal MDCT images served as the reference standard and the percentage lung volume with attenuation values of -950 HU or lower (LAA-950) was evaluated to determine the extent of emphysema. Receiver-operating characteristic (ROC) analysis and generalised estimating equations model were used. ROC analysis revealed significantly better performance (P -950. The diagnostic performance of tomosynthesis was significantly superior to that of radiography for the detection of pulmonary emphysema. In both tomosynthesis and radiography, the sensitivity was affected by the LAA-950. (orig.)

  19. Epidemiology and association of vascular and valvular calcium quantified by multidetector computed tomography in elderly asymptomatic subjects.

    Cury, Ricardo C; Ferencik, Maros; Hoffmann, Udo; Ferullo, Ashley; Moselewski, Fabian; Abbara, Suhny; Booth, Sarah L; O'Donnell, Christopher J; Brady, Thomas J; Achenbach, Stephan

    2004-08-01

    The epidemiology of and association between vascular and valvular calcium as quantified by multidetector computed tomography (MDCT) were studied in 416 elderly subjects with no history of coronary artery disease. Coronary calcium (CC), descending thoracic aortic calcium (DTAC), aortic valve calcium (AVC), and mitral valve calcium (MVC) were present in 282 (68%), 214 (51%), 152 (37%), and 68 (16%) subjects, respectively. Multiple logistic regression analysis showed that after adjusting for age and gender, subjects with AVC (odds ratio [OR] 2.3), MVC (OR 2.81), and DTAC (OR 2.79) were independently and significantly more likely to have CC. Further evidence is provided for the notion that calcifications in those regions are associated and that MDCT can be used as a tool for the global assessment of vascular and valvular calcium. PMID:15276102

  20. Congenital varitans and anomalies of the pancreas and pancreatic duct: Imaging by magnetic resonance cholangiopancreaticography and multidetector computed tomography

    Tuerkvatan, Aysel; Yener, Ouzlem [Dept. of Radiology, Tuerkiye Yueksek Ihtisas Hospital, Ankara (Turkmenistan); Erden, Aysel [Dept. of Radiology, Ankara University School of Medicine, Antalya (Turkmenistan); Tuerkoglu, Mehmet Akif [Dept. of General Surgery, Antalya University School of Medicine, Antalya (Turkmenistan)

    2013-12-15

    Though congenital anomalies of the pancreas and pancreatic duct are relatively uncommon and they are often discovered as an incidental finding in asymptomatic patients, some of these anomalies may lead to various clinical symptoms such as recurrent abdominal pain, nausea and vomiting. Recognition of these anomalies is important because these anomalies may be a surgically correctable cause of recurrent pancreatitis or the cause of gastric outlet obstruction. An awareness of these anomalies may help in surgical planning and prevent inadvertent ductal injury. The purpose of this article is to review normal pancreatic embryology, the appearance of ductal anatomic variants and developmental anomalies of the pancreas, with emphasis on magnetic resonance cholangiopancreaticography and multidetector computed tomography.

  1. Role of multidetector row computed tomography in the assessment of adrenal gland injuries

    Objective: To determine the prevalence of adrenal injuries in a group of patients submitted to multidetector row CT evaluation after blunt trauma and to assess the impact of CT findings on clinical management decisions. Materials and method: During a 4-year period, 2026 emergency CT examinations were performed in the setting of major blunt trauma. A total of 82 patients were retrospectively identified as having adrenal gland traumatic lesions. At multidetector row CT the following findings were considered specific of adrenal injury: round or oval hematoma expanding the adrenal gland, irregular hemorrhage obliterating the gland, uniform adrenal gland swelling, active extravasation of contrast material from the adrenal vessels and adrenal gland rupture. Associated CT findings were: stranding of the periadrenal fat, diffuse hemorrhage in the adjacent retroperitoneum and compression of the adrenal gland by adjacent traumatic lesions. Results: We identified 82 patients (46 males and 36 females, age ranging from 15 to 86 years) with adrenal injuries. The right adrenal gland was injured in 60/82 patients, while the left adrenal gland was injured in 21 cases; in 1 patient bilateral adrenal gland traumatic lesions occurred. In 76 patients with non-isolated adrenal injuries concomitant injuries to the liver (49 cases), ipsilateral kidney (18 cases) and spleen (9 cases) were observed. Round or oval hematoma expanding the adrenal gland (61 cases), irregular hemorrhage obliterating the gland (14 cases), stranding of the periadrenal fat (9 cases) and diffuse hemorrhage in the adjacent retroperitoneum (8 cases) were the more frequent findings detected at CT. Six patients underwent surgical intervention for the presence of major injuries to the spleen (three cases), to the liver (one), to the right kidney (one), to the left kidney (one). Seventy-six patients were conservatively treated. Conclusion: Blunt adrenal injuries typically present as part of a multiorgan trauma

  2. Evaluation of right ventricular function by 64-row CT in patients with chronic obstructive pulmonary disease and cor pulmonale

    Purpose: The aim of this study was to investigate the clinical application value of right ventricle (RV) function measured by 64 multi-detector row CT (MDCT) in patients with chronic obstructive pulmonary disease (COPD) and cor pulmonale. Materials and methods: Sixty-three consecutive patients with COPD and cor pulmonale were referred for electrocardiographically gated MDCT for evaluation of suspected or known coronary artery disease. Magnetic resonance imaging (MRI) for cardiac function analysis was performed on the same day. The MDCT and MRI examinations were successfully completed in 58 patients. Forty-six patients with COPD were divided into three groups according to the severity of disease by the pulmonary function test (PFT). Twelve patients diagnosed as cor pulmonale and 32 control subjects were also included. The RV function and myocardial mass (MM) were obtained by 64-MDCT and 1.5 T cardiac MRI in all of the groups. The results were compared among the groups using the Newman–Keuls method. Pearson's correlation was used to evaluate the relationship between the right ventricular ejection fraction (RVEF) and MM with the PFT results in COPD and cor pulmonale patients. Results: The RVEF was significantly lower in patients with severe COPD and cor pulmonale than it was in those patients with mild or moderate COPD (P < 0.01). There were strong correlations between MDCT and MRI (r = 0.826 for RV MM, r = 0.982 and 0.969 for RV EDV and RV ESV, r = 0.899 for RVEF) and between MDCT results and forced expiratory volume in 1 s (r = 0.787 for RVEF, r = −0.774 for RV MM) in all patients. Conclusion: MDCT can accurately quantify RV function and MM. The RVEF and RV MM measured by MDCT correlate well with the severity of disease as determined by PFT in patients with COPD and cor pulmonale. The assessment of right ventricular function is clinically important for evaluation of the severity of COPD, which may provide an objective basis for therapeutic strategy.

  3. Serial changes of coronary atherosclerotic plaque: Assessment with 64-slice multi-detector computed tomography

    Kim, Eun Young; Kang, Doo Kyoung; Sun, Joo Sung; Choi, So Yeon [Ajou University School of Medicine, Suwon (Korea, Republic of)

    2013-12-15

    Evaluate the progression of coronary atherosclerotic plaque during follow-up, and its association with cardiovascular risk factors. Fifty-six atherosclerotic patients with plaque were enrolled in this retrospective study. Patient's plaque was detected on repeat 64-slice multidetector CT scans with a mean interval of 25 ± 10 months changes in calcified and non-calcified plaque volumes and cardiovascular risk factors were assessed over time. Absolute and relative changes in plaque volume were compared, and the association between rapid progression and cardiovascular risk factors was determined. Diameter of the stenosis, length, calcified and non-calcified lesion plaque volumes increased significantly on follow-up CT. Absolute and relative annual changes in plaque volumes were significantly greater in non-calcified plaque (median, 22.7 mm{sup 3}, 90.4%) than in calcified plaque (median, 0.7 mm{sup 3}, 0%). Obesity, smoking, hypertension, hypercholesterolemia, and low high-density lipoprotein were significant predictors of progression of non-calcified plaque. Progression of calcified plaque was not associated with any cardiovascular risk factors. Coronary plaque volume increased significantly on follow-up CT. The rate of progression is related to non-calcified plaque than to calcified plaque. Cardiovascular risk factors are independently associated with the rapid progression of non-calcified plaque volume, but not associated with the progression of calcified plaque.

  4. Serial changes of coronary atherosclerotic plaque: Assessment with 64-slice multi-detector computed tomography

    Evaluate the progression of coronary atherosclerotic plaque during follow-up, and its association with cardiovascular risk factors. Fifty-six atherosclerotic patients with plaque were enrolled in this retrospective study. Patient's plaque was detected on repeat 64-slice multidetector CT scans with a mean interval of 25 ± 10 months changes in calcified and non-calcified plaque volumes and cardiovascular risk factors were assessed over time. Absolute and relative changes in plaque volume were compared, and the association between rapid progression and cardiovascular risk factors was determined. Diameter of the stenosis, length, calcified and non-calcified lesion plaque volumes increased significantly on follow-up CT. Absolute and relative annual changes in plaque volumes were significantly greater in non-calcified plaque (median, 22.7 mm3, 90.4%) than in calcified plaque (median, 0.7 mm3, 0%). Obesity, smoking, hypertension, hypercholesterolemia, and low high-density lipoprotein were significant predictors of progression of non-calcified plaque. Progression of calcified plaque was not associated with any cardiovascular risk factors. Coronary plaque volume increased significantly on follow-up CT. The rate of progression is related to non-calcified plaque than to calcified plaque. Cardiovascular risk factors are independently associated with the rapid progression of non-calcified plaque volume, but not associated with the progression of calcified plaque.

  5. Congenital anomalies of the coronary arteries: imaging with contrast-enhanced, multidetector computed tomography

    The objective of this study is to evaluate multidetector CT (MDCT) in detecting and characterizing anomalous coronary arteries. Forty-four patients with anomalies of the coronaries were selected from a total of 1758 individuals examined with ECG-gated 4- and 16-row MDCT including thin MIP, MPR and VRT post-processing. Twenty-eight patients showed origin and course anomalies of the central coronary segments, and in this subgroup 13 were judged as ''malignant'' because of interarterial courses between the aortic root and the pulmonary trunk, either of the right coronary artery (n=11) or the left coronary artery (n=2). Twelve non-hemodynamic anomalies were found, affecting the coronary origins only (n=10) or the peripheral vessels courses (n=2). Four arteriovenous fistulas were present, all of them with complex arterial feeders. Regardless of vessel anatomy, coronary opacification was always possible by means of the systemic contrast agent, and the aberrant coronary arteries were visualized synoptically in direct relation to the great mediastinal vessels. In contrast to MDCT, selective cannulation and final diagnosis was possible in only 11 of the 20 catheter angiograms performed (accuracy of 55.0%). In conclusion, its non-invasiveness and precise visualization makes MDCT the standard of reference for evaluating anomalous coronary arteries. (orig.)

  6. Congenital anomalies of the coronary arteries: imaging with contrast-enhanced, multidetector computed tomography

    Schmitt, Rainer; Froehner, Steffen; Wagner, Matthias; Brunner, Horst; Cherevatyy, Oleg; Christopoulos, Georgios [Herz- und Gefaessklinik GmbH, Department of Radiology, Bad Neustadt an der Saale (Germany); Brunn, Juergen; Gietzen, Frank; Kerber, Sebastian [Herz- und Gefaessklinik GmbH, Department of Cardiology, Bad Neustadt an der Saale (Germany); Fellner, Franz [Oberoesterreichische Landesnervenklinik, Department of Radiology, Linz (Austria)

    2005-06-01

    The objective of this study is to evaluate multidetector CT (MDCT) in detecting and characterizing anomalous coronary arteries. Forty-four patients with anomalies of the coronaries were selected from a total of 1758 individuals examined with ECG-gated 4- and 16-row MDCT including thin MIP, MPR and VRT post-processing. Twenty-eight patients showed origin and course anomalies of the central coronary segments, and in this subgroup 13 were judged as ''malignant'' because of interarterial courses between the aortic root and the pulmonary trunk, either of the right coronary artery (n=11) or the left coronary artery (n=2). Twelve non-hemodynamic anomalies were found, affecting the coronary origins only (n=10) or the peripheral vessels courses (n=2). Four arteriovenous fistulas were present, all of them with complex arterial feeders. Regardless of vessel anatomy, coronary opacification was always possible by means of the systemic contrast agent, and the aberrant coronary arteries were visualized synoptically in direct relation to the great mediastinal vessels. In contrast to MDCT, selective cannulation and final diagnosis was possible in only 11 of the 20 catheter angiograms performed (accuracy of 55.0%). In conclusion, its non-invasiveness and precise visualization makes MDCT the standard of reference for evaluating anomalous coronary arteries. (orig.)

  7. Multidetector computed tomography in abdominal emergencies; Multidetektor-CT bei abdominellen Notfaellen

    Zorger, N.; Schreyer, A.G. [Universitaetsklinikum Regensburg (Germany). Institut fuer Roentgendiagnostik

    2009-06-15

    Abdominal emergencies encompass traumatic events in the region of the abdomen as well as the clinical term acute abdomen. Multidetector CT (MDCT) represents one of the most important imaging modalities for detection and correct diagnosis in such abdominal emergencies. Based on the acquired data MDCT allows a stable imaging of the abdomen in an extremely short time even in critically ill patients. Multiplanar reconstructions can be created based on the high resolution data allowing an impressive visualization of the pathology. In this review article the most important abdominal pathologies of the abdomen diagnosed by MDCT are presented with special emphasis on the liver, bile ducts, spleen and kidneys as well as the gastro-intestinal tract. Additionally, MDCT imaging of the individual organ regions will be dealt with in detail. (orig.) [German] Abdominelle Notfaelle beinhalten sowohl traumatische Ereignisse im Bereich des Bauchraums als auch den klinischen Begriff des ''akuten Abdomens''. Die Darstellung solcher Notfaelle mittels Multidetektor-Computertomographie (MDCT) ist eine leistungsfaehige Methode zur Detektion und richtigen Diagnosefindung der abdominellen Notfaelle. Die MDCT erlaubt eine stabile Bildgebung des Abdomens in extrem kurzer Zeit bei schwerkranken Patienten und zudem multiplanare Rekonstruktionen, basierend auf den akquirierten Rohdatensaetzen mit der Moeglichkeit, zusaetzlich Befunde anschaulicher zu visualisieren. In diesem Uebersichtsartikel werden die MDCT-Charakteristika verschiedener abdomineller Notfaelle der wichtigsten Organregionen des Abdomens, wie der Leber und der Gallenwege, des Pankreas, der Milz und der Niere sowie des Gastrointestinaltrakts erlaeutert. Dabei wird speziell auf die Multidetektor-CT-Technik der einzelnen Organregionen eingegangen. (orig.)

  8. [PROGNOSTIC VALUE OF SOME HEMOSTASIS-RELATED, HOMOCYSTEINE, HIGH SENSITIVE C R P AND MULTIDETECTOR COMPUTED TOMOGRAPHY PARAMETERS IN PULMONARY EMBOLISM].

    Todua, F; Akhvlediani, M; Vorobiova, E; Baramidze, A; Tsivtsivadze, G; Gachechiladze, D

    2016-05-01

    Nowadays, an arsenal of diagnostic methods is used in diagnosis of pulmonary embolism, which includes x-ray, angiography, perfusion-ventilation scintigraphy, CT and magnetic resonance imaging, Doppler and laboratory studies. Purpose of our study was to evaluate the diagnostic significance of determination of some parameters of hemostasis (D-dimer, Soluble fibrinmonomer complexes, fibrinogen), homocysteine, hs-CRP and multidetector computed tomography in suspected pulmonary embolism. We have examined 54 patients -31 men and 23 women, aged 18 to 76 years, with characteristics of pulmonary embolism. According to our data, Multidetector computed tomography angiopulmonography , measuring D-dimer, fibrinogen and related hyperhomocysteinemia with increased level of hs-CRP may serve as binding, diagnostically significant laboratory markers in the diagnosis and treatment efficacy of pulmonary thromboembolism. PMID:27348165

  9. Relation of Pulmonary Function Impairment and Coronary Artery Calcification by Multi-detector Computed Tomography in Group Exposed to Inorganic Dusts

    Lee, Won-Jeong; Shin, Jae Hoon; Park, So Young

    2013-01-01

    Background The purpose of this study was to evaluate the relationship of pulmonary function impairment (PFI) and coronary artery calcification (CAC) by multi-detector computed tomography (MDCT), and the effect of pneumoconiosis on CAC or PFI. Methods Seventy-six subjects exposed to inorganic dusts underwent coronary artery calcium scoring by MDCT, spirometry, laboratory tests, and a standardized questionnaire. CAC was quantified using a commercial software (Rapidia ver. 2.8), and all the subj...

  10. Magnetic Resonance Enterography Findings in Crohn′s disease in the Pediatric Population and Correlation with Fluoroscopic and Multidetector Computed Tomographic Techniques

    Parul Patel; Margaret Ormanoski; Hoadley, Kim M.

    2011-01-01

    Traditionally, fluoroscopic examinations such as enteroclysis, upper GI studies, and small bowel follow through exams have been the procedures of choice in evaluating inflammatory bowel disease (IBD) in pediatric populations. With the advent of multidetector computed tomography (MDCT), it has subsequently become a complementary examination in imaging inflammatory bowel disease. A major advantage of MDCT over fluoroscopic examination is its ability to directly visualize bowel mucosa, as well a...

  11. Comparison between Carotid Artery Wall Thickness Measured by Multidetector Row Computed Tomography Angiography and Intimae-Media Thickness Measured by Sonography

    Živorad N. Savić; Ivan I. Soldatović; Milan D. Brajović; Aleksandra M. Pavlović; Dušan R. Mladenović; Vesna D. Škodrić-Trifunović

    2011-01-01

    The increased thickness of the carotid wall >1 mm is a significant predictor of coronary and cerebrovascular diseases. The purpose of our study was to assess the agreement between multidetector row computed tomography angiography (MDCTA) in measuring carotid artery wall thickness (CAWT) and color Doppler ultrasound (CD-US) in measuring intimae-media thickness (IMT). Eighty-nine patients (aged 35–81) were prospectively analyzed using a 64-detector MDCTA and a CD-US scanner. Continuous data wer...

  12. Evaluation of the Pulmonary Veins and Left Atrial Volume using Multidetector Computed Tomography in Patients Undergoing Catheter Ablation for Atrial Fibrillation

    Ito, Hiroki; Dajani, Khaled A.

    2009-01-01

    Catheter ablation is an evolving treatment option in patients with atrial fibrillation. Contrast enhanced electrocardiogram-gated multi-detector computed tomography (MDCT) has rapidly evolved over the past few years into an important tool in the diagnosis of coronary atherosclerosis. There is increasing recognition that MDCT is a useful tool to evaluate non-coronary structures, such as cardiac chambers, valves, the coronary sinus and adjacent structures including pulmonary veins. In particula...

  13. Feasibility of 320-row multi-detector computed tomography angiography to assess bioabsorbable everolimus-eluting vascular scaffolds.

    Asami, Masahiko; Aoki, Jiro; Serruys, Patrick W; Abizaid, Alexandre; Saito, Shigeru; Onuma, Yoshinobu; Kimura, Takeshi; Simonton, Charles A; Tanabe, Kengo

    2016-04-01

    Coronary computer tomographic angiography (CCTA) for screening intra-arterial vessel disease is gaining rapid clinical acceptance in recent years, but its use for such assessments in metal-stented vessel segments is very limited due to blooming artifacts introduced by the metal. However, vessel segments treated by the polymeric everolimus-eluting bioresorbable vascular scaffolds (Absorb) are readily monitored for intravascular disease over time with CCTA. The data on the accuracy of multi-detector computed tomography (MDCT) in patients treated with Absorb is still sparse. Results on 5 Japanese case studies from ABSORB EXTEND are presented here. Five patients were treated with Absorb, and follow-up angiography was conducted at 8 to 14 months as per routine site standard of practice. 320-row MDCT scan was performed within 1 month before the angiography. By MDCT, all Absorb-treated lesions were clearly evaluated and restenosis were not observed. Minimal diameter and % diameter stenosis were similar between MDCT and quantitative angiography (2.07 ± 0.13 vs. 2.03 ± 0.06 mm, P = 0.86, and 22.5 ± 5.0 vs. 21.5 ± 4.5 %, P = 0.88, respectively). MDCT appears to be feasible and useful for evaluating lumen patency and vessel disease in segments implanted with Absorb at follow-up. PMID:26445951

  14. Multidetector Computed Tomography Assessment in Biliary Atresia for the Diagnosis of Portosystemic Collaterals before Liver Transplant

    Introduction: Chronic liver disease increases portal vein pressure and modifies splanchnic circulation. This is particularly significant in infants with biliary atresia. Large collaterals steal portal flow and increase the risk of post transplant portal vein thrombosis. Objective: to describe different types of portosystemic collaterals prior to liver transplantation with low-dose multidetector CT (MDCT) in patients with biliary atresia. Material and methods: 13 patients with severe liver dysfunction due to biliary atresia underwent low-dose 64-MDCT before liver transplantation (effective tube current ranged from 20 to 120 mAs according to weight, with a kilo voltage of 80-120 for all CT). Hepatic arterial and portal venous phases were performed after IV contrast administration [1.5-2 ml/kg]. The mean age of the study group was1 year (range, 4 months to 3.6 years). Two radiologists reviewed the CT images to determine the grade and types of the portosystemic collaterals. Results: A total of 16 CT scans were obtained.the most common portosystemic collaterals found were esophageal (11), gastric submucosal (8), gastric adventitial (7, splenic (7), hemorrhoidal (10), mesenteric [dilated or tortuous branches of the inferior mesenteric vein (8)], retroperitoneal varices [gastro renal shunt (10), splenorenal shunt (4)] and dilated or tortuous left gastric vein (13). Conclusion: MDCT provides important information on venous system patency, presence of varices, and location of venous shunts in pediatric patients with biliary atresia going to liver transplant. in addition, it is critical to detect collaterals that are not evident on ultrasound in order to avoid the steal phenomenon that may lead to portal vein thrombosis and graft failure.

  15. The Prevalance of Myocardial Bridging and Coronary Artery Anomalies with ECG-Gated 64-Row MDCT Coronary Angiography

    Reza Javadrashid

    2009-01-01

    Introduction: An anomalous origin and course of the coronary arteries can be benign or life threatening. Recently, because of new advances in computed tomography technology, radiologists have begun to interpret the diseases of coronary arteries. Our purpose was to demonstrate some remarkable anomalies of the coronary arteries. "nMaterials and Methods: 534 consequent patients referred to Imam Khomeini Hospital of Tabriz university of medical sciences for MDCT coronary angiography were inc...

  16. Measurement of spinal canal narrowing, interpedicular widening, and vertebral compression in spinal burst fractures: plain radiographs versus multidetector computed tomography

    To assess the reliability of measurements of spinal canal narrowing, vertebral body compression, and interpedicular widening in burst fractures in radiography compared with multidetector computed tomography (MDCT). Patients who had confirmed acute vertebral burst fractures over an interval of 34 months underwent both MDCT and radiography. Measurements of spinal canal narrowing, vertebral body compression, and interpedicular widening from MDCT and radiography were compared. The 108 patients (30 female, 78 male, aged 16-79 years, mean 39 years) had 121 burst fractures. Eleven patients had multiple fractures, of which seven were not contiguous. Measurements showed a strong positive correlation between radiography and MDCT (Spearman's rank sum test: spinal canal narrowing k = 0.50-0.82, vertebral compression k = 0.55-0.72, and interpedicular widening k = 0.81-0.91, all P 0.25) and for interpedicular widening in the thoracic spine (k = 0.35, P = 0.115). The average difference in measurements between the modalities was 3 mm or fewer. Radiography demonstrates interpedicular widening, spinal canal narrowing and vertebral compression with acceptable precision, with the exception of those of the cervical spine. (orig.)

  17. Measurement of spinal canal narrowing, interpedicular widening, and vertebral compression in spinal burst fractures: plain radiographs versus multidetector computed tomography

    Bensch, Frank V.; Koivikko, Mika P.; Koskinen, Seppo K. [Helsinki University Central Hospital, Toeoeloe Trauma Center, Helsinki Medical Imaging Center, Department of Radiology, Helsinki (Finland); Kiuru, Martti J. [Suomen Terveystalo Ltd., Helsinki (Finland)

    2009-09-15

    To assess the reliability of measurements of spinal canal narrowing, vertebral body compression, and interpedicular widening in burst fractures in radiography compared with multidetector computed tomography (MDCT). Patients who had confirmed acute vertebral burst fractures over an interval of 34 months underwent both MDCT and radiography. Measurements of spinal canal narrowing, vertebral body compression, and interpedicular widening from MDCT and radiography were compared. The 108 patients (30 female, 78 male, aged 16-79 years, mean 39 years) had 121 burst fractures. Eleven patients had multiple fractures, of which seven were not contiguous. Measurements showed a strong positive correlation between radiography and MDCT (Spearman's rank sum test: spinal canal narrowing k = 0.50-0.82, vertebral compression k = 0.55-0.72, and interpedicular widening k = 0.81-0.91, all P < 0.05), except for the cervical spine (k = -0.50 to 0.61, with all P > 0.25) and for interpedicular widening in the thoracic spine (k = 0.35, P = 0.115). The average difference in measurements between the modalities was 3 mm or fewer. Radiography demonstrates interpedicular widening, spinal canal narrowing and vertebral compression with acceptable precision, with the exception of those of the cervical spine. (orig.)

  18. Planning deep inferior epigastric perforator flaps for breast reconstruction: a comparison between multidetector computed tomography and magnetic resonance angiography

    Cina, A.; Rinaldi, P.; Cipriani, A.; Bonomo, L. [Agostino Gemelli Hospital, Catholic University of Sacred Heart, Department of Radiological Sciences, Rome (Italy); Barone-Adesi, L.; Salgarello, M. [Agostino Gemelli Hospital, Catholic University of Sacred Heart, Department of Surgery, Plastic and Reconstructive Surgery Unit, Rome (Italy); Masetti, R. [Agostino Gemelli Hospital, Catholic University of Sacred Heart, Department of Surgery, Breast Surgery Unit, Rome (Italy)

    2013-08-15

    Deep inferior epigastric perforator (DIEP) flaps have become the state of the art in breast reconstruction. We compared the diagnostic performance of multidetector computed tomography (CTA) and magnetic resonance angiography (MRA) in DIEP flap planning. Twenty-three women (mean age 48.0 years, range 26-72 years) underwent preoperative blinded evaluation using 64-slice CTA and 1.5-T MRA. Perforator identification, measurement of their calibre, intramuscular course (IMC), assessment of direct venous connections (DVC) with main superficial veins, superficial venous communications (SVC) between the right and left hemi-abdomen and deep inferior epigastric artery (DIEA) branching type were performed. Surgery was carried out by the same team. Intraoperative findings were the standard of reference. Accuracy in identifying dominant perforators was 91.3 % for both techniques and mean error in calibre measurement 1.18 {+-} 0.35 mm for CTA and 1.63 {+-} 0.39 mm for MRA. Accuracy in assessing perforator IMCs was 97.1 % for CTA and 88.4 % for MRA, DVC 94.4 % for both techniques, SVC 91.3 % as well, and DIEA branching type 100 % for CTA and 91.3 % for MRA. Image acquisition and interpretation time was 21 {+-} 3 min for CTA (35 {+-} 5 min for MRA). In a strategy to optimise DIEP flap planning avoiding radiation exposure, MRA can be proposed alternatively to CTA. (orig.)

  19. Planning deep inferior epigastric perforator flaps for breast reconstruction: a comparison between multidetector computed tomography and magnetic resonance angiography

    Deep inferior epigastric perforator (DIEP) flaps have become the state of the art in breast reconstruction. We compared the diagnostic performance of multidetector computed tomography (CTA) and magnetic resonance angiography (MRA) in DIEP flap planning. Twenty-three women (mean age 48.0 years, range 26-72 years) underwent preoperative blinded evaluation using 64-slice CTA and 1.5-T MRA. Perforator identification, measurement of their calibre, intramuscular course (IMC), assessment of direct venous connections (DVC) with main superficial veins, superficial venous communications (SVC) between the right and left hemi-abdomen and deep inferior epigastric artery (DIEA) branching type were performed. Surgery was carried out by the same team. Intraoperative findings were the standard of reference. Accuracy in identifying dominant perforators was 91.3 % for both techniques and mean error in calibre measurement 1.18 ± 0.35 mm for CTA and 1.63 ± 0.39 mm for MRA. Accuracy in assessing perforator IMCs was 97.1 % for CTA and 88.4 % for MRA, DVC 94.4 % for both techniques, SVC 91.3 % as well, and DIEA branching type 100 % for CTA and 91.3 % for MRA. Image acquisition and interpretation time was 21 ± 3 min for CTA (35 ± 5 min for MRA). In a strategy to optimise DIEP flap planning avoiding radiation exposure, MRA can be proposed alternatively to CTA. (orig.)

  20. Congenital inferior vena cava anomalies: a review of findings at multidetector computed tomography and magnetic resonance imaging

    Yang, Catherine; Trad, Clovis Simao [Central de Diagnostico Ribeirao Preto (CEDIRP), SP (Brazil); Trad, Henrique Simao, E-mail: hstrad@terra.com.br [Central de Diagnostico Ribeirao Preto (CEDIRP), SP (Brazil); Universidade de Sao Paulo (HC-FMRPUSP), Ribeirao Preto, SP (Brazil). Fac. de Medicina. Hospital das Clinicas; Mendonca, Silvana Machado [Clinica de Diagnostico por Imagem (CDPI), Rio de Janeiro, RJ (Brazil)

    2013-06-15

    Inferior vena cava anomalies are rare, occurring in up to 8.7% of the population, as left renal vein anomalies are considered. The inferior vena cava develops from the sixth to the eighth gestational weeks, originating from three paired embryonic veins, namely the subcardinal, supracardinal and postcardinal veins. This complex ontogenesis of the inferior vena cava, with multiple anastomoses between the pairs of embryonic veins, leads to a number of anatomic variations in the venous return from the abdomen and lower limbs. Some of such variations have significant clinical and surgical implications related to other cardiovascular anomalies and in some cases associated with venous thrombosis of lower limbs, particularly in young adults. The authors reviewed images of ten patients with inferior vena cava anomalies, three of them with deep venous thrombosis. The authors highlight the major findings of inferior vena cava anomalies at multidetector computed tomography and magnetic resonance imaging, correlating them the embryonic development and demonstrating the main alternative pathways for venous drainage. The knowledge on the inferior vena cava anomalies is critical in the assessment of abdominal images to avoid misdiagnosis and to indicate the possibility of associated anomalies, besides clinical and surgical implications. (author)

  1. Comparison of the Multidetector-row Computed Tomographic Angiography Axial and Coronal Planes' Usefulness for Detecting Thoracodorsal Artery Perforators

    Jong Gyu Kim

    2012-07-01

    Full Text Available Background During the planning of a thoracodorsal artery perforator (TDAP free flap,preoperative multidetector-row computed tomographic (MDCT angiography is valuablefor predicting the locations of perforators. However, CT-based perforator mapping of thethoracodorsal artery is not easy because of its small diameter. Thus, we evaluated 1-mm-thickMDCT images in multiple planes to search for reliable perforators accurately.Methods Between July 2010 and October 2011, 19 consecutive patients (13 males, 6females who underwent MDCT prior to TDAP free flap operations were enrolled in this study.Patients ranged in age from 10 to 75 years (mean, 39.3 years. MDCT images were acquired ata thickness of 1 mm in the axial, coronal, and sagittal planes.Results The thoracodorsal artery perforators were detected in all 19 cases. The reliableperforators originating from the descending branch were found in 14 cases, of which 6 hadtransverse branches. The former were well identified in the coronal view, and the latter in theaxial view. The location of the most reliable perforators on MDCT images corresponded wellwith the surgical findings.Conclusions Though MDCT has been widely used in performing the abdominal perforatorfree flap for detecting reliable perforating vessels, it is not popular in the TDAP free flap.The results of this study suggest that multiple planes of MDCT may increase the probabilityof detecting the most reliable perforators, along with decreasing the probability of missingavailable vessels.

  2. Tomosynthesis for the early detection of pulmonary emphysema: diagnostic performance compared with chest radiography, using multidetector computed tomography as reference

    Yamada, Yoshitake [Keio University School of Medicine, Department of Diagnostic Radiology, Tokyo (Japan); Nippon Koukan Hospital, Department of Radiology, Kawasaki-shi, Kanagawa (Japan); Jinzaki, Masahiro; Hashimoto, Masahiro; Shiomi, Eisuke; Kuribayashi, Sachio [Keio University School of Medicine, Department of Diagnostic Radiology, Tokyo (Japan); Abe, Takayuki [Keio University School of Medicine, Center for Clinical Research, Tokyo (Japan); Ogawa, Kenji [Nippon Koukan Hospital, Department of Radiology, Kawasaki-shi, Kanagawa (Japan)

    2013-08-15

    To compare the diagnostic performance of tomosynthesis with that of chest radiography for the detection of pulmonary emphysema, using multidetector computed tomography (MDCT) as reference. Forty-eight patients with and 63 without pulmonary emphysema underwent chest MDCT, tomosynthesis and radiography on the same day. Two blinded radiologists independently evaluated the tomosynthesis images and radiographs for the presence of pulmonary emphysema. Axial and coronal MDCT images served as the reference standard and the percentage lung volume with attenuation values of -950 HU or lower (LAA{sub -950}) was evaluated to determine the extent of emphysema. Receiver-operating characteristic (ROC) analysis and generalised estimating equations model were used. ROC analysis revealed significantly better performance (P < 0.0001) of tomosynthesis than radiography for the detection of pulmonary emphysema. The average sensitivity, specificity, positive predictive value and negative predictive value of tomosynthesis were 0.875, 0.968, 0.955 and 0.910, respectively, whereas the values for radiography were 0.479, 0.913, 0.815 and 0.697, respectively. For both tomosynthesis and radiography, the sensitivity increased with increasing LAA{sub -950}. The diagnostic performance of tomosynthesis was significantly superior to that of radiography for the detection of pulmonary emphysema. In both tomosynthesis and radiography, the sensitivity was affected by the LAA{sub -950}. (orig.)

  3. Anatomical variations of the celiac trunk and hepatic arterial system: an analysis using multidetector computed tomography angiography

    Araujo Neto, Severino Aires; Franca, Henrique Almeida; Mello Junior, Carlos Fernando de; Silva Neto, Eulampio Jose; Negromonte, Gustavo Ramalho Pessoa; Duarte, Claudia Martina Araujo; Cavalcanti Neto, Bartolomeu Fragoso; Farias, Rebeca Danielly da Fonseca, E-mail: severinoaires@hotmail.com [Universidade Federal da Paraiba (UFPB), Joao Pessoa, PB (Brazil)

    2015-11-15

    Objective: To analyze the prevalence of anatomical variations of celiac arterial trunk (CAT) branches and hepatic arterial system (HAS), as well as the CAT diameter, length and distance to the superior mesenteric artery. Materials And Methods: Retrospective, cross-sectional and predominantly descriptive study based on the analysis of multidetector computed tomography images of 60 patients. Results: The celiac trunk anatomy was normal in 90% of cases. Hepatosplenic trunk was found in 8.3% of patients, and hepatogastric trunk in 1.7%. Variation of the HAS was observed in 21.7% of cases, including anomalous location of the right hepatic artery in 8.3% of cases, and of the left hepatic artery, in 5%. Also, cases of joint relocation of right and left hepatic arteries, and trifurcation of the proper hepatic artery were observed, respectively, in 3 (5%) and 2 (3.3%) patients. Mean length and caliber of the CAT were 2.3 cm and 0.8 cm, respectively. Mean distance between CAT and superior mesenteric artery was 1.2 cm (standard deviation = 4.08). A significant correlation was observed between CAT diameter and length, and CAT diameter and distance to superior mesenteric artery. Conclusion: The pattern of CAT variations and diameter corroborate the majority of the literature data. However, this does not happen in relation to the HAS. (author)

  4. Anatomical variations of the celiac trunk and hepatic arterial system: an analysis using multidetector computed tomography angiography

    Objective: To analyze the prevalence of anatomical variations of celiac arterial trunk (CAT) branches and hepatic arterial system (HAS), as well as the CAT diameter, length and distance to the superior mesenteric artery. Materials And Methods: Retrospective, cross-sectional and predominantly descriptive study based on the analysis of multidetector computed tomography images of 60 patients. Results: The celiac trunk anatomy was normal in 90% of cases. Hepatosplenic trunk was found in 8.3% of patients, and hepatogastric trunk in 1.7%. Variation of the HAS was observed in 21.7% of cases, including anomalous location of the right hepatic artery in 8.3% of cases, and of the left hepatic artery, in 5%. Also, cases of joint relocation of right and left hepatic arteries, and trifurcation of the proper hepatic artery were observed, respectively, in 3 (5%) and 2 (3.3%) patients. Mean length and caliber of the CAT were 2.3 cm and 0.8 cm, respectively. Mean distance between CAT and superior mesenteric artery was 1.2 cm (standard deviation = 4.08). A significant correlation was observed between CAT diameter and length, and CAT diameter and distance to superior mesenteric artery. Conclusion: The pattern of CAT variations and diameter corroborate the majority of the literature data. However, this does not happen in relation to the HAS. (author)

  5. Identifying the most infectious lesions in pulmonary tuberculosis by high-resolution multi-detector computed tomography

    This study aimed to determine whether characteristics detected by multi-detector computed tomography (MDCT) were predictive of highly infectious, smear-positive, active pulmonary tuberculosis (PTB). Among 124 patients with active PTB, 84 had positive (group 1) and 40 had negative (group 2) smear results for acid-fast bacilli. Multiplanar MDCT, axial conventional CT and chest X-ray images were analysed retrospectively for morphology, number, and segmental (lobe) distribution of lesions. By multivariate analysis, consolidation over any segment of the upper, middle, or lingual lobes, cavitations, and clusters of nodules were associated with group 1, while centrilobular nodules were predictive of group 2. Using five independent variables associated with risk in group 1, a prediction model was created to distinguish between group 1 and group 2. ROC curve analysis showed an area under the curve of 0.951 ± 0.021 for this prediction model. With the ideal cutoff point score of 1, the sensitivity, specificity, and positive predictive values were 84.5%, 97.5%, and 98.0%, respectively. A model to predict smear-positive active PTB on the basis of findings from MDCT may be a useful tool for clinical decisions about isolating patients pending sputum smear results. (orig.)

  6. Identifying the most infectious lesions in pulmonary tuberculosis by high-resolution multi-detector computed tomography

    Yeh, Jun Jun [Pingtung Christian Hospital, Pingtung (China); Mei-Ho Institute of Technology, Pingtung (China); China Medical University, Taichung (China); Chen, Solomon Chih-Cheng [Pingtung Christian Hospital, Pingtung (China); National Taiwan University, Institute of Occupational Medicine and Industrial Hygiene, College of Public Health, Taipei (China); Teng, Wen-Bao; Chou, Chun-Hsiung; Hsieh, Shih-Peng; Lee, Tsung-Lung [Pingtung Christian Hospital, Pingtung (China); Wu, Ming-Ting [National Yang Ming University, Faculty of Medicine, School of Medicine, Taipei (China); Kaohsiung Veterans General Hospital, Section of Thoracic and Circulation Imaging, Department of Radiology, Kaohsiung (China)

    2010-09-15

    This study aimed to determine whether characteristics detected by multi-detector computed tomography (MDCT) were predictive of highly infectious, smear-positive, active pulmonary tuberculosis (PTB). Among 124 patients with active PTB, 84 had positive (group 1) and 40 had negative (group 2) smear results for acid-fast bacilli. Multiplanar MDCT, axial conventional CT and chest X-ray images were analysed retrospectively for morphology, number, and segmental (lobe) distribution of lesions. By multivariate analysis, consolidation over any segment of the upper, middle, or lingual lobes, cavitations, and clusters of nodules were associated with group 1, while centrilobular nodules were predictive of group 2. Using five independent variables associated with risk in group 1, a prediction model was created to distinguish between group 1 and group 2. ROC curve analysis showed an area under the curve of 0.951 {+-} 0.021 for this prediction model. With the ideal cutoff point score of 1, the sensitivity, specificity, and positive predictive values were 84.5%, 97.5%, and 98.0%, respectively. A model to predict smear-positive active PTB on the basis of findings from MDCT may be a useful tool for clinical decisions about isolating patients pending sputum smear results. (orig.)

  7. Comparative study of earthquake-related and non-earthquake-related head traumas using multidetector computed tomography

    Zhi-gang Chu

    2011-01-01

    Full Text Available OBJECTIVE: The features of earthquake-related head injuries may be different from those of injuries obtained in daily life because of differences in circumstances. We aim to compare the features of head traumas caused by the Sichuan earthquake with those of other common head traumas using multidetector computed tomography. METHODS: In total, 221 patients with earthquake-related head traumas (the earthquake group and 221 patients with other common head traumas (the non-earthquake group were enrolled in our study, and their computed tomographic findings were compared. We focused the differences between fractures and intracranial injuries and the relationships between extracranial and intracranial injuries. RESULTS: More earthquake-related cases had only extracranial soft tissue injuries (50.7% vs. 26.2%, RR=1.9, and fewer cases had intracranial injuries (17.2% vs. 50.7%, RR = 0.3 compared with the non-earthquake group. For patients with fractures and intracranial injuries, there were fewer cases with craniocerebral injuries in the earthquake group (60.6% vs. 77.9%, RR = 0.8, and the earthquake-injured patients had fewer fractures and intracranial injuries overall (1.5 + 0.9 vs. 2.5 +1.8; 1.3 + 0.5 vs. 2.1 + 1.1. Compared with the non-earthquake group, the incidences of soft tissue injuries and cranial fractures combined with intracranial injuries in the earthquake group were significantly lower (9.8% vs. 43.7%, RR = 0.2; 35.1% vs. 82.2%, RR = 0.4. CONCLUSION: As depicted with computed tomography, the severity of earthquake-related head traumas in survivors was milder, and isolated extracranial injuries were more common in earthquake-related head traumas than in non-earthquake-related injuries, which may have been the result of different injury causes, mechanisms and settings.

  8. Visualization of pulmonary vein stenosis after radio frequency ablation for treatment of atrial fibrillation using multidetector computed tomography with retrospective gating

    Purpose: With the number of radio frequency ablations (RFA) for treatment of chronic atrial fibrillation increasing, the diagnostic evaluation for RFA associated pulmonary vein stenosis is getting more important. This study investigates the feasibility of the visualization of pulmonary vein stenosis using non-invasive multidetector computed tomography. Materials and Methods: Twenty-eight patients were examined following RFA-treatment. A 4-slice (20 patients) and a 16-slice (8 patients) multidetector CT scanner (SOMATOM Volume Zoom and Sensation 16, Siemens, Forchheim, Germany) with retrospective gating was used to assess the pulmonary veins. Lesion severity was determined on a semi-quantitative scale ( 50%). Results: CT was performed without any complications in all patients. Diagnostic image quality could be obtained in all examinations. The pulmonary veins showed lesions 50% in one patient. Eighteen patients showed no lesions. Conclusion: Multidetector CT of the pulmonary veins seems to be able to visualize high-grade and low-grade lesions, but larger catheter-controlled studies are needed for further assessment of the diagnostic accuracy and clinical reliability of this noninvasive method. (orig.)

  9. The Prevalance of Myocardial Bridging and Coronary Artery Anomalies with ECG-Gated 64-Row MDCT Coronary Angiography

    Reza Javadrashid

    2009-01-01

    Full Text Available Introduction: An anomalous origin and course of the coronary arteries can be benign or life threatening. Recently, because of new advances in computed tomography technology, radiologists have begun to interpret the diseases of coronary arteries. Our purpose was to demonstrate some remarkable anomalies of the coronary arteries. "nMaterials and Methods: 534 consequent patients referred to Imam Khomeini Hospital of Tabriz university of medical sciences for MDCT coronary angiography were included in this study. The patients were 14-84 years old (mean±SD, 54±116 years. 334 patients (64.41% were men, and 190 (35.58% were women. All the examinations were evaluated by both a radiologist and a cardiologist. "nResults: The incidence of anomalous anatomical origin and course of the coronaries found in our study group was 8.43% (n = 45. The anomalies found in our study were ectopic origin of the RCA from the left coronary cusp (n = 2, 0.37%, absence of the left main coronary artery (n = 1, 0.18%, ectopic origin of the left main coronary artery from the right sinus of Valsalva (n = 3, 0.54%, ectopic origin of LAD from RCA (n = 2, 0.36%, ectopic origin of the left circumflex artery from the right sinus of Valsalva (n = 3, 0.54%, AV fistula (n=2 0.36% and myocardial bridging (n = 32, 5.99%. "nConclusion: An anomalous origin of the coronary anatomy must be present in the interpretations because of its importance for patients, cardiologists and surgeons. We suggest that MDCT could be a non-invasive alternative imaging technique to conventional coronary angiography for screening the anomalous vessels of coronary arteries because of its excellent spatial resolution, which is very important for detecting the relationship of anomalous vessels with great arteries and cardiac structures.  

  10. Myocardial bridging of the right coronary artery inside the right atrial myocardium identified by ECG-gated 64-slice multidetector computed tomography angiography.

    Chen, Chien-Cheng; Chen, Huan-Wu; Fu, Chen-Ju; Lin, Fen-Chiung; Wen, Ming-Shien; Liu, Yuan-Chang

    2010-01-01

    A myocardial bridge (MB) is defined as an intramyocardial course of a major epicardial coronary artery, and it is mainly confined to the left ventricle and the left anterior descending coronary artery. There are rare reports of right coronary MB seen during angiographic examination. Herein, we present a 49 year-old man with right coronary artery MB without luminal narrowing in the diastolic and systolic phases of electrocardiography-gated computed tomography images. The value of multi-detector computed tomography for the detection of anatomical variants in the cardiovascular system is further discussed. PMID:20438676

  11. High-resolution computed tomography in patients with atypical 'cardiac' chest pain: a study investigating patients at 10-year cardiovascular risks defined by the Framingham and PROCAM scores

    Choon Kiat ANG; Kui Hian SIM; Alan Yean Yip FONG; Sze Piaw CHIN; Tiong Kiam ONG; Seyfarth M Tobias; Wei Ling CHAN; Chee Khoon LIEW; Rapaee ANNUAR; Houng Bang LIEW

    2006-01-01

    Background and objective Atypical 'cardiac' chest pain (ACCP) is not usually caused by myocardial ischaemia. Current noninvasive investigations for these symptoms are not yet as accurate as invasive coronary angiography. The latest 64-row multi-detector computed tomography (MDCT) technology is non-invasive, has high specificity and negative predictive values for the detection of significant coronary disease. Our aim was to investigate if this modality can provide more information in the assessment of outpatients with ACCP in addition to established cardiovascular risk scores. Methods Seventy consecutive patients presenting to the outpatient clinic with ACCP underwent 64-row MDCT scan of the coronary arteries. They were categorized into low, medium or high risk groups based upon the Framingham and PROCAM scores. We defined a clinically abnormal MDCT scan as coronary stenosis =50% or calcium score >400 Agatston. Results Fifty-three (75.7%) patients did not have clinically abnormal scans. Framingham score classified 43 patients as low-risk while PROCAM classified 59 patients as low-risk. MDCT scans were abnormal for 18.6% and 22.0% of the respective low-risk group of patients. For patients with medium-to-high risk, 33.3% and 36.4% of Framingham and PROCAM patient groups respectively had abnormal MDCT scans. Conclusion MDCT adds valuable information in the assessment of patients with ACCP by identifying a significant proportion of patients categorized as low-risk to have underlying significant coronary stenosis and coronary calcification by established cardiovascular risk scores.

  12. Volumetric analysis of coronary plaque characterization in patients with metabolic syndrome using 64-slice multi-detector computed tomography

    Metabolic syndrome (MetS) is associated with adverse cardiovascular events and mortality, where acute coronary syndrome significantly impacts on mortality and morbidity. In contrast, evidences have accumulated that the lipid-rich plaque might play a critical role in acute coronary syndrome. The study population consisted of 94 patients with suspected angina pectoris who underwent multi-detector computed tomography (MDCT). Of those, we identified 41 with MetS. In MDCT analysis, low-density plaque volume (LDPV) (42±28 vs 24±18 mm3, P=0.0003), moderate-density plaque volume (105±41 vs 82±33 mm(3), P=0.003), total plaque volume (164±70 vs 118±59 mm3), P=0.0008) and %LDPV (24.2±10.0 vs 18.3±7.1%, P=0.01) were significantly increased in the MetS group compared to the non-MetS group. Multivariate linear regression analysis after adjusting for confounding variables revealed that MetS was significantly correlated with an increase in %LDPV (β=0.48, P=0.0001). Multivariate logistic regression analysis for lipid-rich plaque after adjusting for confounding variables indicated that MetS was significantly associated with lipid-rich plaque (odds ratio: 5.99, 95% confidence intervals: 1.94-18.6, P=0.002). Patients with MetS were strongly related to having a lipid-rich composition in their coronary plaque, as detected by MDCT. (author)

  13. Value of Multidetector Computed Tomography in Evaluation of Thoracic Venous Abnormalities among Pediatrics with Congenital Heart Disease

    Dalia F Elbeih*, Mervat M El-Gohary *, Naglaa H Shebrya*,Mohammed A Saleh

    2013-04-01

    Full Text Available Introduction: Venous anomalies of the thorax can involve systemic or pulmonary veins and range from isolated incidental findings to components of more complex anomalies, most often congenital heart disease (CHD. Although echocardiography and catheter directed cardiac angiography are generally accepted as the primary imaging techniques for evaluation of CHD, CT and MRI are important complementary diagnostic tools. Multi-detector computed tomography (MDCT with its increasing availability and utility is now becoming a further method of imaging CHD. In light of its widespread availability, MDCT and 3D imaging are increasingly considered as a viable “one-stop shop” for preoperative imaging evaluation of cardiovascular structures in selected pediatric patients.Aim of the work: The aim of this work is to evaluate the role of MDCT in visualization of the thoracic venous system in pediatrics with congenital heart disease, show prevalence and types of venous anomalies and to compare this data with echocardiographic findings.Methods: The studied group included 30 cases referred to us by pediatric cardiologists to be examined by MSCT angiography of the heart and thoracic vessels. All the patients were known cases of congenital heart disease and underwent echocardiography. They were referred to answer specific anatomic question raised by inconclusive echocardiography, to assess suspected systemic and suspected pulmonary venous anomalies. All patients were subjected to full history taking, clinical examination and MDCT examination with CT lightspeed VCT XT 64-detectors row scanner (General Electric, Medical Systems, Milwaukee, Wisconsin, USA.Results: CTA findings had 77.8 % concordance with echocardiographic findings regarding SVC anomalies, 66.7 % concordance with echocardiography regarding IVC anomalies and 90 % concordance regarding pulmonary venous anomalies.Conclusion: Low dose protocol CTA is a promising method that complementary to Echocardioraphy

  14. Quantification of myocardial delayed enhancement and wall thickness in hypertrophic cardiomyopathy: Multidetector computed tomography versus magnetic resonance imaging

    Zhao, Lei [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, No. 2 Anzhen Rd Beijing (China); Ma, Xiaohai, E-mail: maxi8238@gmail.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, No. 2 Anzhen Rd Beijing (China); Feuchtner, Gudrun Maria [Department of Radiology II, Innsbruck Medical University, Innsbruck (Austria); Zhang, Chen; Fan, Zhanming [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, No. 2 Anzhen Rd Beijing (China)

    2014-10-15

    Objectives: To evaluate the accuracy of multidetector computed tomography (MDCT) in assessing myocardial delayed enhancement and left ventricle wall thickness in hypertrophic cardiomyopathy (HCM) compared with cardiac magnetic resonance (CMR) as the reference standard. Materials and methods: Eighty consecutive patients (59 male; 53.2 ± 13.0 years) were examined with MDCT, followed by CMR 1 day later. Cardiac CT angiography and a delayed CT were performed. CMR was performed according to a standardized protocol. Left ventricle wall thickness and positions of myocardial delayed enhancement were identified in both CMR and CT images according to the American Heart Association left ventricle 17-segment model. Myocardial delayed enhancement was characterized as “dense” (areas with clear defined borders) or “diffuse” and then quantified using both techniques. Results: Left ventricle wall thickness determined by MDCT was significantly correlated with CMR (R = 0.88, P < 0.01). Compared with CMR, MDCT accurately diagnosed 74 of 78 (94.9%) patients and 1243 of 1326 (93.7%) segments. For dense myocardial delayed enhancement, MDCT significantly correlated with CMR (R = 0.88, P < 0.01) and slightly underestimated myocardial delayed enhancement (mean, −3.85%; lower and upper limits of agreement, −13.40% and 5.70%, respectively). Conclusions: MDCT provides reliable quantification of myocardial delayed enhancement and evaluation of left ventricle wall thickness and has a good correlation with CMR in patients with HCM when a comprehensive cardiac CT protocol is used and can be applied for intervention planning.

  15. Comparison of diagnostic accuracy of Magnetic Resonance Imaging and Multidetector Computed Tomography in the detection of pelvic fractures

    Henes, F.O., E-mail: fhenes@uke.de [Department of Diagnostic and Interventional Radiology, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246 Hamburg (Germany); Nüchtern, J.V. [Department of Trauma-, Hand- and Reconstructive Surgery, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246 Hamburg (Germany); Groth, M.; Habermann, C.R.; Regier, M. [Department of Diagnostic and Interventional Radiology, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246 Hamburg (Germany); Rueger, J.M. [Department of Trauma-, Hand- and Reconstructive Surgery, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246 Hamburg (Germany); Adam, G. [Department of Diagnostic and Interventional Radiology, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246 Hamburg (Germany); Großterlinden, L.G. [Department of Trauma-, Hand- and Reconstructive Surgery, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246 Hamburg (Germany)

    2012-09-15

    Objective: To compare diagnostic accuracy and interobserver reliability of Magnetic Resonance Imaging (MRI) and Multidetector Computed Tomography (MDCT) in the detection of acute pelvic fractures. Materials and methods: In 38 consecutive patients (mean age 74.7 years) with a positive finding of anterior pelvis fracture in the conventional X-rays, pelvic MRI and MDCT were performed for further evaluation of pelvic ring fractures. Two radiologists independently read all data sets. Sensitivity and specificity were calculated based on mean scores for each method. Sensitivities of CT and MRI were compared using a paired proportion test (McNemar). Diagnostic validity of both methods was assessed by the interobserver variability using kappa statistics. Combined clinical data and findings from all imaging studies served as the reference standard. Results: 122 fractures were identified in the reference standard (37 sacral, 58 pubic, 22 acetabular, 1 ischial, 4 ilial). On average, MRI detected 96.3% whereas CT detected 77% of all fractures. With regard to sensitivity, MRI proved to be significantly better compared to MDCT (observer 1, p = 0.0009; observer 2, p = 0.0003 by observer 2). In particular, MRI performed better in the depiction of sacral fractures, reaching a sensitivity of 98.6% compared to 66.1% at CT. The interobserver variability was determined to be very good (k = 0.955 for MRI and 0.902 for MDCT). Conclusion: MRI reaches a significantly higher sensitivity than CT in the detection of acute pelvic fractures, particularly of the sacrum. Especially in elderly patients with suspicion of a sacral fracture and negative results at MDCT, MRI may be considered as the next step in diagnostic workup.

  16. Effect of age and plaque morphology on diagnostic accuracy of dual source multidetector computed tomography coronary angiography

    Hamza Sunman; Giray Kabak; Lale Tokgzolu; Ali Oto; Kudret Aytemir; Hikmet Yorgun; Uur Canpolat; Ali Taher; Edis Demiri; Tuncay Hazrolan; Leventahiner; Ergn B.Kaya

    2014-01-01

    Background Multidetector computed tomography (MDCT) coronary angiography represents one of the most exciting technological revolutions in cardiac imaging and it has been increasingly used in the diagnosis of coronary artery disease. The purpose of this study is to investigate the effect of age and coronary plaque calcification on diagnostic accuracy of MDCT. Methods The patients were examined by using dual-source MDCT and conventional coronary angiography. MDCT results were analyzed with regard to the severity (>50%stenosis) and morphology (non-calcified, mixed, or calcified) of coronary atherosclerotic plaques evaluated in a 16-segment model. Results In total, 181 patients (94 men and 87 women) with 2,687 coronary artery segments were examined with MDCT. Ninety three patients were older than 65 years of age (group A, 42 men) and 88 were younger (group B, 52 men). Two-hundred nine coronary artery segments (7.2%) were ex-cluded because of small distal coronary vessel segments and/or motion artifacts. The overall number of segments with non-diagnostic image quality was similar in both groups of patients. Of the 2,687 evaluated segments, 157 (5.8%) were significantly diseased, and 144 of them were correctly detected by MDCT. Diagnostic evaluation showed that the sensitivity, positive predictive value, specificity, and negative pre-dictive value were 89.5%, 62.5%, 96.0%, and 99.2%, respectively in group A, and 95.2%, 64.8%, 97.5%, and 99.8%in group B, respectively. In addition, detailed segment-based analyses in coronary segments with non-calcified, mixed and calcified plaques in both groups were simi-lar diagnostic accuracy. Conclusions Very high diagnostic accuracy observed in this study suggests that MDCT coronary angiography could be a suitable diagnostic tool for not only younger patients but also for older patients.

  17. Pelvic crush fractures in survivors of the Sichuan earthquake evaluated by digital radiography and multidetector computed tomography

    To investigate the profile of pelvic crush fractures in earthquake victims on digital radiography (DR) and multidetector computed tomography (MDCT). One hundred and sixty-seven consecutive survivors of the 2008 Sichuan earthquake with pelvic crush fractures classified into types according to the Tile classification system, entered our study. One hundred and thirty-nine, and 28 patients underwent DR and MDCT scans, respectively. Data were reviewed retrospectively focusing on anatomical sites, numbers, and classification of pelvic ring fractures. Pelvic fractures occurred in the pubis in 88 patients (52.7%), in other pelvic bones in 32 (19.16%), and in both the pubis and other pelvic bones in 47 (28.14%). Pubic fractures were more common than fractures of other pelvic bones, and involvement of bilateral pubis was more common than that of the left or right pubis (all p < 0.05). As for the numbers of pelvic bones involved, multiple fractures occurred in 48.52% patients (81 out of 167) composed predominantly of fractures of two bones in 58.02% (47 out of 81), and were seen more often in bilateral pubis than in any other pelvic bones (p < 0.05). Regarding classifications of pelvic ring fractures, they were Type A in 31 patients (18.56%); Type B in 72 (43.11%), predominantly Type B2 in 26 (15.58%) and Type B3 in 28 (16.77%); and Type C in 64 (38.32%), predominantly Type C3 in 40 (23.95%). Pelvic crush fractures particularly including multiple pelvic fractures, occurring predominantly in bilateral pubis, and composed of Type C3 followed by Type B3 and Type B2, could be considered to be the profile of pelvic crush fractures in an earthquake. (orig.)

  18. Multi-detector computed tomography in non-traumatic urologic emergencies; Multidetektor-CT bei nichttraumatischen urologischen Notfaellen

    Scherr, M.K. [Ludwig-Maximilians-Universitaet Muenchen (Germany). Institut fuer Klinische Radiologie

    2009-06-15

    Today's modern multi-detector computer tomography (MDCT) with its fast gantry rotation enables scanning of large body volumes with high temporal and spatial resolution. The fast acquisition of data and subsequent data reconstruction enables multiphase protocols with short time gaps between consecutive scan series so that large numbers of scans within one respiratory pause are possible and even in cases of non-cooperative patients acceptable quality of image data is provided. The acquired thin-slice raw data with isotropic submillimeter voxels can be visualized with different reconstruction algorithms. The aadvantages of imaging for diagnostics in urologic emergencies are the excellent visualization of acute arterial and venous pathologies, detailed assessment of renal parenchyma and the precise depiction of the urinary tract. In non-trauma settings this enables detailed visualization of inflammatory diseases and differentiation of obstructive or post-therapeutic pathologies along the upper and lower urinary tract. Based on these MDCT findings adequate therapy planning and planning of interventional or surgical procedures can be carried out. (orig.) [German] Durch den Einsatz moderner Multidetektor-Computertomographen (MDCT) mit schnellen Gantryrotationszeiten sind heute grosse Scanvolumina in hoher zeitlicher und mit hoher raeumlicher Aufloesung moeglich. Die schnelle Bilddatenakquisition und -verarbeitung ermoeglichen Mehrphasenprotokolle mit mehreren kurz aufeinander folgenden Scanserien innerhalb jeweils eines Atemanhalts und eine akzeptable Bildqualitaet bei unkooperativen Patienten. Diese fuehren zu duennschichtigen Rohdaten mit isotropen Voxel im Submillimeterbereich, die mit verschiedenen Nachrekonstruktionsverfahren optimal visualisiert werden koennen. Die urologische Notfalldiagnostik profitiert hier von der hervorragenden Darstellbarkeit akuter Gefaesspathologien in der arteriellen und venoesen Vaskularisation der Nieren. Die renale

  19. Study of radiation dose to the eye lens by multi-detector row computed tomography of the temporal bone

    The exposure of the eye lens caused by multi-detector row computed tomography (MDCT) of the temporal bone is a serious problem. Our aim was to evaluate the radiation dose to the eye lens by different scan baselines (orbitomeatal line; OML, acanthiomeatal line; AML) and examine the difference of the depiction of the temporal bone structures. Measurement of the exposure to the eye lens was performed by means of MDCT of the temporal bone with a radio-photoluminescence glass dosimeter using a rand phantom. Moreover, we studied only one volunteer (58-year-old male) who had no symptom and was not suspected of having any ear abnormalities with a two scan baseline. Visualization of the major anatomical structures of the temporal bone (the tympanic portion of the facial nerve canal, the body of the incus, stapes superstructures, vestibule etc.) was performed on the volunteer. The average absorbed dose was 6.42 mGy by the OML and 1.59 mGy by the AML, respectively. With regard to visualization of the temporal bone structures, all structures were of equal quality with the two scan baseline. With the AML line, the radiation dose to the eye lens was reduced to 75%. Therefore, the authors recommended an AML for use for MDCT of the temporal bone. In clinical practice, the optimization of scanning factor (kVp, mAs etc.) and the use of the radio-protection should be implemented for radiation dose reduction of the eye lens by MDCT of the temporal bone. (author)

  20. Multidetector-row computed tomography for evaluating the branching angle of the celiac artery: a descriptive study

    We performed this study in order to investigate the shape of the origin of the celiac artery in maximum intensity projection (MIP) using routine 64 multidetector-row computed tomography (MDCT) data in order to plan for the implantation of an intra-arterial hepatic port system. A total of 1,104 patients with hepatocellular carcinoma were assessed with MDCT. In the definition of the branching angle, the anterior side of the abdominal aorta was considered the baseline, and the cranial and caudal sides were designated as 0 and 180 degrees, respectively. The angles between 0 and 90 degrees and between 90 and 180 degrees from the cranial side were considered upward and downward, respectively, and the branching angle of the celiac artery was classified every 30 degrees. The subclavian arterial route was used for the implantation of an intra-arterial hepatic port system in patients with branching angles of 150 degrees or more (sharp downward). The median branching angle was (median ± standard deviation) 135 ± 23 (range, 51–174) degrees. The branching was upward in 77 patients (7%) and downward in 1,027 patients (93%). The branching was downward with an angle of 120 to150 degrees in most patients (n = 613). The branching was sharply downward with an angle of 150 degrees or more in 177 patients (16%). A total of 10 patients were referred for interventional placement of an intra-arterial hepatic port system. The subclavian arterial route was used for implantation of an intra-arterial hepatic port system in 2 patients with sharp downward branching. The branching angle of the celiac artery can be easily determined by the preparation of MIP images from routine MDCT data. MIP may provide useful information for the selection of the catheter insertion route in order to avoid a sharp branching angle of the celiac artery

  1. Radiation dose reduction effects of prospective ECG-gated helical scan with high helical pitch in coronary multidetector computed tomography

    High radiation dose of conventional retrospective electrocardiogram (ECG)-gated coronary MDCT (multidetector computed tomography) with regular helical pitch (HP) continuous scan has disturbed wide clinical use. The purpose was to estimate the radiation dose reduction effects of FlashScan, which was a prospective ECG-gated helical scan with high HP. Coronary MDCT was performed by Aquilion 64 Super Heart (Toshiba) in 474 patients (M/F=280/194, mean age: 65±11 years old, mean height: 161±10 cm, body weight: 62±13 kg, body mass index (BMI): 23.9±3.4) with heart rate (HR) ≤60 and without arrhythmia before scan. Mean HP (BP) which was automatically decided by the FlashScan system was 15.3±1.0 (0.239±0.016) when the gantry rotation speed was 0.35 s/rot. In 6 patients, arrhythmias occurred during scan and data deficits were observed on their images. In the remaining 468 patients, image quality was excellent. Mean dose length product (DLP) of the FlashScan (499±119 mGy·cm) was significantly (P<0.0001) lower than that of retrospective continuous scan with regular HP (1281±286 mGy·cm) or than that of modulation scan (927±202 mGy·cm), and mean scan time of the FlashScan (6.9±0.6 s) was also significantly (P<0.0001) shorter than that of retrospective continuous scan with regular HP (8.8±0.6 s). The FlashScan was a useful method to reduce patients' radiation dose and scan time in patients with HR ≤60 and without arrhythmia. (author)

  2. Quantification of myocardial delayed enhancement and wall thickness in hypertrophic cardiomyopathy: Multidetector computed tomography versus magnetic resonance imaging

    Objectives: To evaluate the accuracy of multidetector computed tomography (MDCT) in assessing myocardial delayed enhancement and left ventricle wall thickness in hypertrophic cardiomyopathy (HCM) compared with cardiac magnetic resonance (CMR) as the reference standard. Materials and methods: Eighty consecutive patients (59 male; 53.2 ± 13.0 years) were examined with MDCT, followed by CMR 1 day later. Cardiac CT angiography and a delayed CT were performed. CMR was performed according to a standardized protocol. Left ventricle wall thickness and positions of myocardial delayed enhancement were identified in both CMR and CT images according to the American Heart Association left ventricle 17-segment model. Myocardial delayed enhancement was characterized as “dense” (areas with clear defined borders) or “diffuse” and then quantified using both techniques. Results: Left ventricle wall thickness determined by MDCT was significantly correlated with CMR (R = 0.88, P < 0.01). Compared with CMR, MDCT accurately diagnosed 74 of 78 (94.9%) patients and 1243 of 1326 (93.7%) segments. For dense myocardial delayed enhancement, MDCT significantly correlated with CMR (R = 0.88, P < 0.01) and slightly underestimated myocardial delayed enhancement (mean, −3.85%; lower and upper limits of agreement, −13.40% and 5.70%, respectively). Conclusions: MDCT provides reliable quantification of myocardial delayed enhancement and evaluation of left ventricle wall thickness and has a good correlation with CMR in patients with HCM when a comprehensive cardiac CT protocol is used and can be applied for intervention planning

  3. Usefulness and safety of propranolol injection into vein for acquisition of coronary multidetector-row computed tomography

    A low heart rate (HR), associated with a prolonged slow filling phase (SF), is necessary to obtain a high quality coronary CT at a low radiation dose with conventional 64 multidetector-row computed tomography (MDCT). The purpose of our study was to confirm the safety of injecting propranolol (2-10 mg) into the vein for lowering heart rate in patients requiring MDCT and to document the effect of the drug on HR, PQ and SF. Of 1290 consecutive patients who were initially considered for enrollment in the coronary MDCT study, 40 patients with atrial fibrillations, 3 with atrial flutters, and 13 with artificial pacemakers were excluded. Of the remaining 1234 patients (M/F=714/520), 331 had already taken an oral beta-blocker before the CT examination, and were included in the study. In patients with no contraindications, propranolol was aggressively injected (2-10 mg) into the vein to reduce the HR. In patients not taking an oral beta blocker, 2 mg propranolol reduced the HR by -10±5 bpm and 10 mg, by -20±7 bpm. However, in patients taking an oral beta-blocker, the decrease in HR by propranolol was minimal (2 mg, -6±4 bpm; 10 mg, -10±6 bpm). Propranolol significantly prolonged the PQ interval (from 169±27 to 179±29 ms, P<0.0001), and SF (from 125±69 to 264±79 ms, P<0.0001). Adverse effects of propranolol injection were observed in only 3 [2 mild hypotension and 1 paroxysmal atrial fibrillation (recovered to sinus rhythm by DC counter shock)] of 3212 patients. All 3 patients became stable after 1 or 2 hours of rest and could return home. Propranolol injection was a relatively safe and useful method to reduce HR and prolong SF, necessary for obtaining high quality coronary MDCT with a low radiation dose. (author)

  4. Myocardial Bridging of the Right Coronary Artery inside the Right Atrial Myocardium Identified by ECG-gated 64-slice Multidetector Computed Tomography Angiography

    Yung-Liang Wan

    2010-04-01

    Full Text Available A myocardial bridge (MB is defined as an intramyocardial course of a major epicardialcoronary artery, and it is mainly confined to the left ventricle and the left anterior descendingcoronary artery. There are rare reports of right coronary MB seen during angiographicexamination. Herein, we present a 49 year-old man with right coronary artery MB withoutluminal narrowing in the diastolic and systolic phases of electrocardiography-gated computedtomography images. The value of multi-detector computed tomography for the detectionof anatomical variants in the cardiovascular system is further discussed.

  5. Computer-aided detection of lung nodules on multidetector row computed tomography using three-dimensional analysis of nodule candidates and their surroundings

    We have been developing a computer-aided detection (CAD) system for lung nodules on multidetector row computed tomography (MDCT). The scheme for nodule detection in this system is featured by three-dimensional analysis for nodule detection in nodules and their surroundings, which is designed to discriminate nodules from blood vessels. The purpose of this study was to evaluate the CAD system. MDCT images from 30 patients with lung nodules were read twice, 3 weeks apart by a chest radiologist to detect noncalcified nodules of ≥4 mm. The first reading was without CAD, and the second reading was with CAD. Based on the reference standard later determined by another chest radiologist, the sensitivity of the former chest radiologist without or with CAD was obtained; the sensitivity and false-positive rate of the system alone were also obtained. The reference standard consisted of 66 nodules. The sensitivity of the chest radiologist was 77% (51/66) without CAD and 91% (60/66) with CAD, showing a significant improvement. The CAD system alone showed a sensitivity of 79% (52/66) with the false-positive rate of 4.5 per patient. Although preliminary, these results indicate the efficacy of the CAD system. (author)

  6. Comparison of Multidetector Computed Tomography and Flat-Panel Computed Tomography Regarding Visualization of Cortical Fractures, Cortical Defects, and Orthopedic Screws

    Neubauer, Jakob; Benndorf, Matthias; Lang, Hannah; Lampert, Florian; Kemna, Lars; Konstantinidis, Lukas; Neubauer, Claudia; Reising, Kilian; Zajonc, Horst; Kotter, Elmar; Langer, Mathias; Goerke, Sebastian M.

    2015-01-01

    Abstract To compare the visualization of cortical fractures, cortical defects, and orthopedic screws in a dedicated extremity flat-panel computed tomography (FPCT) scanner and a multidetector computed tomography (MDCT) scanner. We used feet of European roe deer as phantoms for cortical fractures, cortical defects, and implanted orthopedic screws. FPCT and MDCT scans were performed with equivalent dose settings. Six observers rated the scans according to number of fragments, size of defects, size of defects opposite orthopedic screws, and the length of different screws. The image quality regarding depiction of the cortical bone was assessed. The gold standard (real number of fragments) was evaluated by autopsy. The correlation of reader assessment of fragments, cortical defects, and screws with the gold standard was similar for FPCT and MDCT. Three readers rated the subjective image quality of the MDCT to be higher, whereas the others showed no preferences. Although the image quality was rated higher in the MDCT than in the FPCT by 3 out of 6 observers, both modalities proved to be comparable regarding the visualization of cortical fractures, cortical defects, and orthopedic screws and of use to musculoskeletal radiology regarding fracture detection and postsurgical evaluation in our experimental setting. PMID:26252281

  7. Comparison of Multidetector Computed Tomography and Flat-Panel Computed Tomography Regarding Visualization of Cortical Fractures, Cortical Defects, and Orthopedic Screws: A Phantom Study.

    Neubauer, Jakob; Benndorf, Matthias; Lang, Hannah; Lampert, Florian; Kemna, Lars; Konstantinidis, Lukas; Neubauer, Claudia; Reising, Kilian; Zajonc, Horst; Kotter, Elmar; Langer, Mathias; Goerke, Sebastian M

    2015-08-01

    To compare the visualization of cortical fractures, cortical defects, and orthopedic screws in a dedicated extremity flat-panel computed tomography (FPCT) scanner and a multidetector computed tomography (MDCT) scanner.We used feet of European roe deer as phantoms for cortical fractures, cortical defects, and implanted orthopedic screws. FPCT and MDCT scans were performed with equivalent dose settings. Six observers rated the scans according to number of fragments, size of defects, size of defects opposite orthopedic screws, and the length of different screws. The image quality regarding depiction of the cortical bone was assessed. The gold standard (real number of fragments) was evaluated by autopsy.The correlation of reader assessment of fragments, cortical defects, and screws with the gold standard was similar for FPCT and MDCT. Three readers rated the subjective image quality of the MDCT to be higher, whereas the others showed no preferences.Although the image quality was rated higher in the MDCT than in the FPCT by 3 out of 6 observers, both modalities proved to be comparable regarding the visualization of cortical fractures, cortical defects, and orthopedic screws and of use to musculoskeletal radiology regarding fracture detection and postsurgical evaluation in our experimental setting. PMID:26252281

  8. Renal replacement lipomatosis: multidetector-row computed tomography findings in one case

    Replacement lipomatosis of the kidney is the result of severe atrophy of the renal parenchyma often caused by chronic calculus disease with secondary marked benign proliferation of fibrofatty tissue replacing atrophied renal parenchyma. Different radiological modalities have been used to illustrate this entity, with magnetic resonance imaging, ultrasound, intravenous pyelogram, and computed tomography (CT) used most frequently. We report multidedector CT (MDCT) findings of replacement lipomatosis in a 50-year-old woman. We think that it accurately provides a complete one-step diagnostic workup and appropriate pre-surgical planning for patients for whom there is a suspicion of replacement lipomatosis

  9. Renal replacement lipomatosis: multidetector-row computed tomography findings in one case

    Calisir, C.; Can, C.; Kebapci, M. [Dept. of Radiology and Dept. of Urology, Medical Faculty, Eskisehir Osmangazi Univ, Eskisehir (Turkey)

    2007-02-15

    Replacement lipomatosis of the kidney is the result of severe atrophy of the renal parenchyma often caused by chronic calculus disease with secondary marked benign proliferation of fibrofatty tissue replacing atrophied renal parenchyma. Different radiological modalities have been used to illustrate this entity, with magnetic resonance imaging, ultrasound, intravenous pyelogram, and computed tomography (CT) used most frequently. We report multidedector CT (MDCT) findings of replacement lipomatosis in a 50-year-old woman. We think that it accurately provides a complete one-step diagnostic workup and appropriate pre-surgical planning for patients for whom there is a suspicion of replacement lipomatosis.

  10. Computer-aided detection of lung nodules on multidetector CT in concurrent-reader and second-reader modes: A comparative study

    Purpose: To compare the reading times and detection performances of radiologists in concurrent-reader and second-reader modes of computer-aided detection (CAD) for lung nodules on multidetector computed tomography (CT). Materials and Methods: Fifty clinical multidetector CT datasets containing nodules up to 20 mm in diameter were retrospectively collected. For the detection and rating of non-calcified nodules larger than 4 mm in diameter, 6 radiologists (3 experienced radiologists and 3 resident radiologists) independently interpreted these datasets twice, once with concurrent-reader CAD and once with second-reader CAD. The reference standard of nodules in the datasets was determined by the consensus of two experienced chest radiologists. The reading times and detection performances in the two modes of CAD were statistically compared, where jackknife free-response receiver operating characteristic (JAFROC) analysis was used for the comparison of detection performances. Results: Two hundreds and seven nodules constituted the reference standard. Reading time was significantly shorter in the concurrent-reader mode than in the second-reader mode, with the mean reading time for the 6 radiologists being 132 s with concurrent-reader CAD and 210 s with second-reader CAD (p < 0.01). JAFROC analysis revealed no significant difference between the detection performances in the two modes, with the average figure-of-merit value for the 6 radiologists being 0.70 with concurrent-reader CAD and 0.72 with second-reader CAD (p = 0.35). Conclusion: In CAD for lung nodules on multidetector CT, the concurrent-reader mode is more time-efficient than the second-reader mode, and there can be no significant difference between the two modes in terms of detection performance of radiologists

  11. Computer-aided detection of lung nodules on multidetector CT in concurrent-reader and second-reader modes: A comparative study

    Matsumoto, Sumiaki, E-mail: sumatsu@med.kobe-u.ac.jp [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Ohno, Yoshiharu, E-mail: yoshirad@kobe-u.ac.jp [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Aoki, Takatoshi, E-mail: a-taka@med.uoeh-u.ac.jp [Department of Radiology, University of Occupational and Environmental Health School of Medicine, Iseigaoka 1-1, Yahatanishi-ku, Kitakyushu 807-8555 (Japan); Yamagata, Hitoshi, E-mail: hitoshi.yamagata@toshiba.co.jp [Toshiba Medical Systems Corporation, 1385 Shimoishigami, Otawara, Tochigi 324-8550 (Japan); Nogami, Munenobu, E-mail: aznogami@med.kobe-u.ac.jp [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Department of Radiology, Kochi Medical School, Nankoku, Kochi 783-8505 (Japan); Matsumoto, Keiko, E-mail: palm_kei@yahoo.co.jp [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Department of Radiology, Yamanashi Hospital of Social Insurance, 3-8-31 Asahi, Kofu, Yamanashi 400-0025 (Japan); Yamashita, Yoshiko, E-mail: yoshiko_yama1208goma@yahoo.co.jp [Department of Radiology, University of Occupational and Environmental Health School of Medicine, Iseigaoka 1-1, Yahatanishi-ku, Kitakyushu 807-8555 (Japan); Sugimura, Kazuro, E-mail: sugimura@med.kobe-u.ac.jp [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan)

    2013-08-15

    Purpose: To compare the reading times and detection performances of radiologists in concurrent-reader and second-reader modes of computer-aided detection (CAD) for lung nodules on multidetector computed tomography (CT). Materials and Methods: Fifty clinical multidetector CT datasets containing nodules up to 20 mm in diameter were retrospectively collected. For the detection and rating of non-calcified nodules larger than 4 mm in diameter, 6 radiologists (3 experienced radiologists and 3 resident radiologists) independently interpreted these datasets twice, once with concurrent-reader CAD and once with second-reader CAD. The reference standard of nodules in the datasets was determined by the consensus of two experienced chest radiologists. The reading times and detection performances in the two modes of CAD were statistically compared, where jackknife free-response receiver operating characteristic (JAFROC) analysis was used for the comparison of detection performances. Results: Two hundreds and seven nodules constituted the reference standard. Reading time was significantly shorter in the concurrent-reader mode than in the second-reader mode, with the mean reading time for the 6 radiologists being 132 s with concurrent-reader CAD and 210 s with second-reader CAD (p < 0.01). JAFROC analysis revealed no significant difference between the detection performances in the two modes, with the average figure-of-merit value for the 6 radiologists being 0.70 with concurrent-reader CAD and 0.72 with second-reader CAD (p = 0.35). Conclusion: In CAD for lung nodules on multidetector CT, the concurrent-reader mode is more time-efficient than the second-reader mode, and there can be no significant difference between the two modes in terms of detection performance of radiologists.

  12. Effect of computer-aided detection as a second reader in multidetector-row CT colonography

    Our purpose was to assess the effect of computer-aided detection (CAD) on lesion detection as a second reader in computed tomographic colonography, and to compare the influence of CAD on the performance of readers with different levels of expertise. Fifty-two CT colonography patient data-sets (37 patients: 55 endoscopically confirmed polyps ≥0.5 cm, seven cancers; 15 patients: no abnormalities) were retrospectively reviewed by four radiologists (two expert, two nonexpert). After primary data evaluation, a second reading augmented with findings of CAD (polyp-enhanced view, Siemens) was performed. Sensitivities and reading time were calculated for each reader without CAD and supported by CAD findings. The sensitivity of expert readers was 91% each, and of nonexpert readers, 76% and 75%, respectively, for polyp detection. CAD increased the sensitivity of expert readers to 96% (P = 0.25) and 93% (P = 1), and that of nonexpert readers to 91% (P = 0.008) and 95% (P = 0.001), respectively. All four readers diagnosed 100% of cancers, but CAD alone only 43%. CAD increased reading time by 2.1 min (mean). CAD as a second reader significantly improves sensitivity for polyp detection in a high disease prevalence population for nonexpert readers. CAD causes a modest increase in reading time. CAD is of limited value in the detection of cancer. (orig.)

  13. Findings in multidetector computed tomography in the diagnosis of hepatocellular carcinoma in patients with cirrhosis and correlation with pathology of liver explants

    Objectives: To describe the imagenological behavior of hepatocellular carcinoma in cirrhotic patients using a dynamic multidetector computed tomography (MDCT) technique, and correlate these findings with histological tumor grades. Materials and methods: A retrospective, descriptive observational study was conducted to evaluate 51 nodules in 32 liver transplant patients diagnosed with liver cirrhosis. The pathology of liver explants was used as a reference. Nodules with hepatocellular carcinoma histopathology were retrospectively analyzed by computed tomography scans performed pre-transplant. Using a dynamic multidetector computed tomography technique, we evaluated the most common imagenological behavior reported in the literature: arterial enhancement, washout, capsule, and intratumoral arterial vessels. Results: Forty-six of 51 (90%) tumors showed arterial enhancement. Of the 46 tumors with arterial enhancement, 39 (85%) had washout in portal-late phase. Five of 51 (10%) were hypovascular. Twenty-two of 51 (43%) had capsule and 12 of 51 (24%) showed intratumoral arterial vessels. The more frequent image combination was the combination of arterial enhancement and washout (39 of 51 tumors or 76%). The most frequent histological grade was II (35 of 51 tumors or 69%). Statistically significant relationships were found between histological grade tumors and imagenological behavior: arterial enhancement and hypovascular. Conclusion: In our population, arterial enhancement with washout in portal-late phases was observed in most of the tumors. Our results are consistent with previously reported studies, demonstrating the high reliability of this imaging pattern for the diagnosis of hepatocellular carcinoma. (authors)

  14. Patterns of myocardial perfusion in humans evaluated with contrast-enhanced 320 multidetector computed tomography

    Kühl, J Tobias; Linde, Jesper J; Fuchs, Andreas;

    2012-01-01

    intravenous adenosine infusion on regional myocardial perfusion. To evaluate myocardial perfusion patterns at rest, we scanned 14 healthy subjects with PET and 14 age and gender matched subjects with 320 MDCT. To evaluate the effect of adenosine stress on relative perfusion patterns 14 subjects with near......Left ventricular (LV) myocardial contrast enhancement can be recorded using 320 multi detector computed tomography (MDCT). We aimed to (1) assess patterns of regional myocardial perfusion at rest and compare them with NH(3) positron emission tomography (PET) (2) and to assess the effect of......-normal epicardial coronary arteries were studied at rest and during adenosine stress. Relative perfusion was assessed as attenuation density (AD) in 16 segments of the LV, and each segment was divided into 3 layers: endo-, mid- and epi-cardial. During rest the relative AD by MDCT was lower in the lateral wall...

  15. Distribution of Mitral Annular and Aortic Valve Calcium as Assessed by Unenhanced Multidetector Computed Tomography.

    Koshkelashvili, Nikoloz; Codolosa, Jose N; Goykhman, Igor; Romero-Corral, Abel; Pressman, Gregg S

    2015-12-15

    Aging is associated with calcium deposits in various cardiovascular structures, but patterns of calcium deposition, if any, are unknown. In search of such patterns, we performed quantitative assessment of mitral annular calcium (MAC) and aortic valve calcium (AVC) in a broad clinical sample. Templates were created from gated computed tomography (CT) scans depicting the aortic valve cusps and mitral annular segments in relation to surrounding structures. These were then applied to CT reconstructions from ungated, clinically indicated CT scans of 318 subjects, aged ≥65 years. Calcium location was assigned using the templates and quantified by the Agatston method. Mean age was 76 ± 7.3 years; 48% were men and 58% were white. Whites had higher prevalence (p = 0.03) and density of AVC than blacks (p = 0.02), and a trend toward increased MAC (p = 0.06). Prevalence of AVC was similar between men and women, but AVC scores were higher in men (p = 0.008); this difference was entirely accounted for by whites. Within the aortic valve, the left cusp was more frequently calcified than the others. MAC was most common in the posterior mitral annulus, especially its middle (P2) segment. For the anterior mitral annulus, the medial (A3) segment calcified most often. In conclusion, AVC is more common in whites than blacks, and more intense in men, but only in whites. Furthermore, calcium deposits in the mitral annulus and aortic valve favor certain locations. PMID:26517948

  16. Sex estimation based on scapula analysis in a Japanese population using multidetector computed tomography.

    Torimitsu, Suguru; Makino, Yohsuke; Saitoh, Hisako; Sakuma, Ayaka; Ishii, Namiko; Yajima, Daisuke; Inokuchi, Go; Motomura, Ayumi; Chiba, Fumiko; Yamaguchi, Rutsuko; Hashimoto, Mari; Hoshioka, Yumi; Iwase, Hirotaro

    2016-05-01

    Accurate sex estimation based on measurements of dimorphic dimensions in human unknown remains is important as the first step toward making individual identification. The purpose of this study was to assess the sexual dimorphism of the scapula and to quantify the accuracy of sex estimation in a contemporary Japanese forensic sample using scapular measurements based on three-dimensional (3D) computed tomographic (CT) images. A total of 218 cadavers (109 males, 109 females) that underwent postmortem CT and subsequent forensic autopsy were used. Ten scapular measurements were performed on 3D CT reconstructed images that extracted only bone data, and were analyzed using descriptive statistics and discriminant function analyses (DFA). All measurements were dimorphic in terms of sex differences. Univariate DFA provided sex classification accuracy rates of 75.7-91.3%. Stepwise DFA yielded sex prediction accuracy rates of 93.1-94.5%. In conclusion, the scapular measurements using 3D CT images of a contemporary Japanese population may be useful for the estimation of skeletal sex in the field of forensic anthropology. PMID:26965402

  17. Detection of pulmonary embolism using 64-slice multidetector-row computed tomography: accuracy and reproducibility on different image reconstruction parameters

    Jung, Jung Im; Ahn, Myeong Im; Park, Seog Hee (Dept. of Radiology, Seoul St Mary' s Hospital, College of Medicine, The Catholic Univ. of Korea (Korea, Republic of)), email: jijung@catholic.ac.kr; Kim, Ki Jun (Deparment of Radiology, Incheon St Mary' s Hospital, College of Medicine, The Catholic Univ. of Korea (Korea, Republic of)); Kim, Hyo Rim (Deparment of Radiology, Yeouido St Mary' s Hospital, College of Medicine, The Catholic Univ. of Korea (Korea, Republic of)); Park, Hyun Jin (Dept. of Radiology, St Vincent Hospital, College of Medicine, The Catholic Univ. of Korea (Korea, Republic of)); Jung, SeungHee; Lim, Hyeon Woo (Deparment of Preventive Medicine, College of Medicine, The Catholic Univ. of Korea (Korea, Republic of))

    2011-05-15

    Background Direct comparison of different image reconstruction parameters to detect pulmonary embolism (PE) using 64-slice multidetector-row computed tomography (MDCT) is absent and the most accurate image reconstruction parameters have not yet been proven. Purpose To compare different image reconstruction parameters for detecting PE using 64-slice MDCT in patients suspected of having an acute PE. Material and Methods Forty patients who underwent pulmonary CT angiography with 64-slice MDCT for a suspected PE were included. Different image reconstruction parameters were used for each patient: axial and coronal images with slice thicknesses of 0.625 mm, 1.3 mm, and 2.5 mm and axial maximum intensity projection (MIP) images with slab thicknesses of 1.3 mm, 2.5 mm, and 5 mm. Four experienced radiologists reviewed the images. The diagnosis of a PE was based on consensus review of axial 0.625 mm slice thickness images by two chest radiologists with allowing multiplanar reconstruction. Accuracy and reproducibility (kappa value) were evaluated. Results In 15 of 40 patients, a PE was diagnosed. For detecting lobar PEs, axial images with a slice thickness of 1.25 mm and all coronal re-formatted images showed comparable results to axial images with a slice thickness of 0.625 mm. For detecting segmental PEs, axial images with a slice thickness of 1.25 mm and coronal images with a slice thickness of 0.625 mm re-formatted images showed comparable results to axial images of a slice thickness of 0.625 mm. For detecting subsegmental PEs, axial images with a slice thickness of 0.625 mm showed the highest sensitivity. Better reproducibility was obtained when the thinner slice thickness reconstructions were in axial and coronal images. However, reproducibility of MIP images with slab thicknesses of 2.5 mm and 5 mm was similar for detecting segmental and subsegmental PEs. Conclusion Thin-slice reconstruction of less than 1 mm is mandatory for visualization of PE at the subsegmental

  18. Spinopelvic dissociation: multidetector computed tomographic evaluation of fracture patterns and associated injuries at a single level 1 trauma center.

    Gupta, Pushpender; Barnwell, Jonathan C; Lenchik, Leon; Wuertzer, Scott D; Miller, Anna N

    2016-06-01

    The objective of the present study is to evaluate multidetector computed tomographic (MDCT) fracture patterns and associated injuries in patients with spinopelvic dissociation (SPD). Our institutional trauma registry database was reviewed from Jan. 1, 2006, to Sept. 30, 2012, specifically evaluating patients with sacral fractures. MDCT scans of patients with sacral fractures were reviewed to determine the presence of SPD. SPD cases were characterized into the following fracture patterns: U-shaped, Y-shaped, T-shaped, H-shaped, and burst. The following MDCT features were recorded: level of the horizontal fracture, location of vertical fracture, kyphosis between major fracture fragments, displacement of fracture fragment, narrowing of central spinal canal, narrowing of neural foramina, and extension into sacroiliac joints. Quantitative evaluation of the sacral fractures was performed in accordance with the consensus statement by the Spine Trauma Study Group. Medical records were reviewed to determine associated pelvic and non-pelvic fractures, bladder and bowel injuries, nerve injuries, and type of surgical intervention. Twenty-one patients had SPD, of whom 13 were men and eight were women. Mean age was 41.8 years (range 18.8 to 87.7). Five fractures (24 %) were U-shaped, six (29 %) H-shaped, four (19 %) Y-shaped, and six (29 %) burst. Nine patients (43 %) had central canal narrowing, and 19 (90 %) had neural foramina narrowing. Eleven patients (52 %) had kyphotic angulation between major fracture fragments, and seven patients (33 %) had either anterior (24 %) or posterior (10 %) displacement of the proximal fracture fragment. Fourteen patients (67 %) had associated pelvic fractures, and 20 (95 %) had associated non-pelvic fractures. Two patients (10 %) had associated urethral injuries, and one (5 %) had an associated colon injury. Seven patients (33 %) had associated nerve injuries. Six patients (29 %) had surgical fixation while 15 (71 %) were

  19. The role of 64-slice multi-detector computed tomography in the detection of subclinical atherosclerosis of the coronary artery.

    Jeong, Hae Chang; Ahn, Youngkeun; Ko, Jum Suk; Lee, Min Goo; Sim, Doo Sun; Park, Keun Ho; Yoon, Nam Sik; Youn, Hyun Ju; Hong, Young Joon; Kim, Kye Hun; Park, Hyung Wook; Kim, Ju Han; Kim, Yun-Hyeon; Jeong, Myung Ho; Cho, Jeong Gwan; Park, Jong Chun; Kang, Jung Chaee

    2010-12-01

    Multi-detector computed tomography (MDCT) has been used for detecting or excluding coronary atherosclerotic stenosis in symptomatic patients. However, the role of MDCT for routine medical examination in asymptomatic, high-risk patients has not been established. We therefore conducted the present study to test the hypothesis that MDCT could be a valuable method for detecting subclinical coronary artery stenosis in asymptomatic patients. An observational, retrospective, single-centre study was conducted with a cohort of 1,529 patients (mean age, 56.4 ± 8.3 years; 1,353 males) who had undergone MDCT as part of their general medical checkups from November 2005 to April 2008. The patients who had a past history of coronary artery disease, typical chest pain, or evidence of myocardial ischemia were excluded. During clinical follow up of these patients, the incidence of subclinical coronary stenosis and the usefulness of MDCT for routine medical examination in asymptomatic patients were investigated. Of the 1,529 enrolled patients, 42.3% had hypertension, 13.5% had diabetes mellitus, 7.7% had hyperlipidemia, and 40.4% were current smokers. Abnormal MDCT findings were noted in 560 (36.6%) patients, who were classified into two groups. One group had the presence coronary calcium with a luminal diameter stenosis of the coronary artery of bridge, and 23 patients (1.5%) presented with significant stenosis. The patients with significant stenosis underwent percutaneous coronary intervention (PCI) with stent implantation. Major adverse cardiac events occurred in only 2 patients who had been treated with PCI during a mean follow-up period of 387 ± 253 days. The incidence of significant subclinical coronary stenosis as detected by MDCT in a general medical check-up was 3.4%, and the false-positive rate of MDCT for detecting significant coronary artery stenosis was 55.8% (29/52). 64-Slice MDCT can be a useful tool for noninvasive evaluation of coronary arteries in

  20. Simple area-based measurement for multidetector computed tomography to predict left ventricular size

    Schlett, Christopher L.; Kwait, Dylan C.; Mahabadi, Amir A.; Hoffmann, Udo [Massachusetts General Hospital, and Harvard Medical School, Cardiac MR PET CT Program, Boston, MA (United States); Bamberg, Fabian [Massachusetts General Hospital, and Harvard Medical School, Cardiac MR PET CT Program, Boston, MA (United States); University Hospitals Munich, and Ludwig Maximilians University, Department of Clinical Radiology, Munich (Germany); O' Donnell, Christopher J. [Lung and Blood Institute' s Framingham Heart Study, National Heart, Framingham (United States); Fox, Caroline S. [Lung and Blood Institute' s Framingham Heart Study, National Heart, Framingham (United States); Brigham and Women' s Hospital, and Harvard Medical School, Division of Endocrinology, Metabolism, and Diabetes, Department of Medicine, Boston, MA (United States)

    2010-07-15

    Measures of left ventricular (LV) mass and dimensions are independent predictors of morbidity and mortality. We determined whether an axial area-based method by computed tomography (CT) provides an accurate estimate of LV mass and volume. A total of 45 subjects (49% female, 56.0 {+-} 12 years) with a wide range of LV geometry underwent contrast-enhanced 64-slice CT. LV mass and volume were derived from 3D data. 2D images were analysed to determine LV area, the direct transverse cardiac diameter (dTCD) and the cardiothoracic ratio (CTR). Furthermore, feasibility was confirmed in 100 Framingham Offspring Cohort subjects. 2D measures of LV area, dTCD and CTR were 47.3 {+-} 8 cm{sup 2}, 14.7 {+-} 1.5 cm and 0.54 {+-} 0.05, respectively. 3D-derived LV volume (end-diastolic) and mass were 148.9 {+-} 45 cm{sup 3} and 124.2 {+-} 34 g, respectively. Excellent inter- and intra-observer agreement were shown for 2D LV area measurements (both intraclass correlation coefficients (ICC) = 0.99, p < 0.0001) and could be confirmed on non-contrast CT. The measured 2D LV area was highly correlated to LV volume, mass and size (r = 0.68; r = 0.73; r = 0.82; all p < 0.0001, respectively). On the other hand, CTR was not correlated to LV volume, mass, size or 2D LV area (all p > 0.27). Compared with traditionally used CTR, LV size can be accurately predicted based on a simple and highly reproducible axial LV area-based measurement. (orig.)

  1. A Multicenter, Open-Label Study of an Intravenous Short-Acting β1-Adrenergic Receptor Antagonist Landiolol Hydrochloride for Coronary Computed Tomography Angiography by 16-Slice Multi-Detector Computed Tomography in Japanese Patients with Suspected Ischemic Cardiac Disease

    Hirano, Masaharu; Yamashina, Akira; Hara, Kazuhiro; Ikari, Yuji; Jinzaki, Masahiro; Iino, Misako; Yamaguchi, Takuhiro; Tanimoto, Mitsunobu; Kuribayashi, Sachio; ,

    2014-01-01

    Background During coronary computed tomography (CT) angiography (CCTA), β-blockers (β-adrenergic receptor antagonists) have commonly been used to lower heart rate and improve image quality. Objectives The aim of this study was to investigate the image quality-improving effect as well as the heart rate-lowering effect of landiolol hydrochloride (an intravenous short-acting β1-adrenergic receptor antagonist) in CCTA by 16-slice multi-detector CT (MDCT). Methods A total of 39 subjects suspected ...

  2. Multiparametric multidetector computed tomography scanning on suspicion of hyperacute ischemic stroke: validating a standardized protocol Avaliação multiparamétrica por tomografia computadorizada multidetectores na suspeita de isquemia cerebral hiperaguda: validando um protocolo padronizado

    Felipe Torres Pacheco

    2013-06-01

    Full Text Available Multidetector computed tomography (MDCT scanning has enabled the early diagnosis of hyperacute brain ischemia. We aimed at validating a standardized protocol to read and report MDCT techniques in a series of adult patients. The inter-observer agreement among the trained examiners was tested, and their results were compared with a standard reading. No false positives were observed, and an almost perfect agreement (Kappa>0.81 was documented when the CT angiography (CTA and cerebral perfusion CT (CPCT map data were added to the noncontrast CT (NCCT analysis. The inter-observer agreement was higher for highly trained readers, corroborating the need for specific training to interpret these modern techniques. The authors recommend adding CTA and CPCT to the NCCT analysis in order to clarify the global analysis of structural and hemodynamic brain abnormalities. Our structured report is suitable as a script for the reproducible analysis of the MDCT of patients on suspicion of ischemic stroke.A tomografia computadorizada multidetectores (TCMD permitiu o diagnóstico precoce de isquemia cerebral hiperaguda. O presente estudo objetivou validar a interpretação e a descrição padronizada de um protocolo de TCMD multiparamétrica em uma série de pacientes adultos. A concordância entre os examinadores foi testada, e seus resultados confrontados com uma leitura padrão. Não foram observados resultados falso-positivos, e foi documentado um elevado grau de concordância (Kappa>0,81 quando os dados da angiotomografia (ATC e dos mapas de perfusão cerebral por TC (PCTC foram adicionados à análise da TC sem contraste (TCSC. A concordância interobservador foi superior para os leitores melhor treinados, corroborando a necessidade de formação específica para a interpretação dos exames. Os autores recomendam acrescer a interpretação da ATC e da PCTC à análise da TCSC, visando à análise global das anormalidades cerebrais estruturais e hemodin

  3. Visualization of congenital thoracic vascular anomalies using multi-detector row computed tomography and two- and three-dimensional post-processing

    Schertler, Thomas [Department of Medical Radiology, Institute of Diagnostic Radiology, University Hospital Zurich (Switzerland); Wildermuth, Simon [Institute of Diagnostic Radiology, Kantonsspital St.Gallen (Switzerland)]. E-mail: Simon.Wildermuth@kssg.ch; Teodorovic, Ninoslav [Department of Medical Radiology, Institute of Diagnostic Radiology, University Hospital Zurich (Switzerland); Mayer, Dieter [Division of Cardiovascular Surgery, University Hospital Zurich (Switzerland); Marincek, Borut [Department of Medical Radiology, Institute of Diagnostic Radiology, University Hospital Zurich (Switzerland); Boehm, Thomas [Department of Medical Radiology, Institute of Diagnostic Radiology, University Hospital Zurich (Switzerland); Department of Medical Radiology, Institute of Diagnostic Radiology, Kantonsspital Chur (Switzerland)

    2007-01-15

    Anomalies of the vascular system are caused by false embryogenesis and are therefore present from birth. Single-detector row spiral computed tomography angiography (CTA) and multi-detector row computed tomography angiography (MDCTA) have gained increasing importance in the non-invasive assessment of vascular pathologies and replace conventional angiography in many cases. High-resolution volumetric datasets that are acquired during a single breath-hold give the possibility of two- (2D) and three-dimensional (3D)-post-processing. Due to post-processing, even complex vascular malformations are visualized in an understandable way. Furthermore, CTA, in contrast to conventional angiography, depicts not only the vascular structures but also allows assessment of the surrounding anatomical structures. We present cases of rare congenital anomalies of the thoracic vessels using MDCT with special respect to 2D- and 3D-post-processing.

  4. A model for quantitative correction of coronary calcium scores on multidetector, dual source, and electron beam computed tomography for influences of linear motion, calcification density, and temporal resolution : A cardiac phantom study

    Greuter, M. J. W.; Groen, J. M.; Nicolai, L. J.; Dijkstra, H.; Oudkerk, M.

    2009-01-01

    Purpose: The objective of this study is to quantify the influence of linear motion, calcification density, and temporal resolution on coronary calcium determination using multidetector computed tomography (MDCT), dual source CT (DSCT), and electron beam tomography (EBT) and to find a quantitative me

  5. Clinico-statistical study of preoperative examination for the dental implant using multi-detector row computed tomography

    In April 2006, a new affiliated hospital opened at Nihon University School of Dentistry at Matsudo, and the latest model was introduced into the department of radiology. CT examinations for preoperative dental implant going on 64 multi-detector row CT, the number of cases has increased. CT examination is useful for preoperative dental implant, and many studies of concerning clinical studies using CT images have been reported. The purpose of this study was to the clinico-statistical studies of preoperative CT examinations for dental implant at our radiology department using 64 multi-detector row CT. The subjects consisted of 5174 regions in 1312 cases of preoperative CT examinations, between April 2006 and December 2007. CT machine used was the Aquilion TM64 (Toshiba Medical Systems, Japan), and the workstation used was the ZIOSTATION (ZIOSOFT, Japan). All of CT examinations were performed the position of implant placement and disease examined from CT findings. The following results were obtained: The 1312 cases consisted of 426 males and 886 females. Patient age ranged from 16 yrs to 86 yrs old, the average age were 55.5 yrs old. Six hundred and seventy four cases were ordered at another private dental office not our hospital, and 638 cases were ordered at our hospital. The numbers of implant placement were on the average of 3.9, and the rate got higher with age. The lesions which detected by preoperative CT examination were maxillary sinusitis, periodontitis, ectopic calcification, and mucous retention cyst. (author)

  6. Multidetector computed tomography angiography in clinically suspected hyperacute ischemic stroke in the anterior circulation: an etiological workup in a cohort of Brazilian patients

    Felipe Torres Pacheco

    2015-05-01

    Full Text Available Objective The potential of computed tomography angiography (CTA was assessed for early determination of stroke subtypes in a Brazilian cohort of patients with stroke. Method From July 2011 to July 2013, we selected patients with suspected hyperacute stroke (< 6 hours. Intracranial and cervical arteries were scrutinized on CTA and their imaging features were correlated with concurrent subtype of stroke. Results Stroke was documented in 50/106 selected patients (47.2% based on both clinical grounds and imaging follow-up (stroke group, with statistically significant arterial stenosis and vulnerable plaques on CTA. Intracranial large artery disease was demonstrated in 34% of patients in the stroke group. Partial territorial infarct prevailed (86% while artery-to-artery embolization was the most common stroke mechanism (52%. Conclusion Multidetector CTA was useful for the etiologic work-up of hyperacute ischemic stroke and facilitated the knowledge about the topographic pattern of brain infarct in accordance with its causative mechanism.

  7. Imaging aid for thoracic surgery. Multidetector-row computed tomography evaluation of the tracheobronchial structure and bronchial tube selection for one-lung anesthesia

    The tracheobronchial structures were evaluated by multidetector-row computed tomography (MDCT), which provided imaging information for one-lung anesthesia during thoracic surgery. The subjects consisted of 100 patients. Three-dimensional (3D) images of the tracheobronchial structures and the bronchial tubes were created. Individual differences were found in the tracheobronchial structures in 100 patients. The length and the diameter of the right main bronchus were measured with 3D images and were not related to the patient's physical appearance, such as body height. Problematic intubation cases included a short right main bronchus <10 mm, an anomaly of the right bronchus, and tracheal stenosis. The 3D images demonstrated problematic areas of the tracheobronchial structure and helped the anesthesiologists select the most appropriate bronchial tube suitable for the tracheobronchial structure variations. Therefore, this technique is considered to contribute to safer performance of one-lung anesthesia. (author)

  8. Multidetector computed tomography-guided treatment strategy in patients with non-ST elevation acute coronary syndromes: a pilot study

    Patients with non-ST elevation acute coronary syndrome (ACS) and evidence of myocardial ischaemia are scheduled for coronary angiography (CAG). In most patients CAG remains a single diagnostic procedure only. A prospective study was performed to evaluate whether 16-slice multidetector CT (MDCT) could predict treatment of the patients and to determine how many CAGs could have been prevented by MDCT scanning prior to CAG. Twenty-two patients with ACS were scanned prior to CAG. Based on MDCT data, a fictive treatment was proposed and compared to CAG-based treatment. Excellent accuracy was observed to detect significant stenoses using MDCT (sensitivity 94%, specificity 96%). In 45%, no PCI was performed during CAG, because of the absence of significant coronary artery disease (27%) or severe coronary artery disease, demanding CABG (18%). MDCT predicted correct treatment in 86%. By using MDCT data, 32% of the CAGs could have been prevented. (orig.)

  9. Assessment of left ventricular volumes using multi-detector row computed tomography (MDCT). Phantom and human studies

    Multi-detector row CT (MDCT) is a new noninvasive modality for coronary artery imaging. Using the same MDCT data obtained for coronary artery assessment, left ventricular (LV) volumes such as end-diastolic (ED) and end-systolic (ES) volumes (EDV and ESV, respectively) and ejection fraction (EF) can potentially be assessed when ED and ES datasets are extracted. The purpose of this study was to evaluate the feasibility of MDCT in the assessment of LV volumes. Using a pulsating heart phantom (EDV=143 ml, ESV=107 ml, stroke volume=36 ml, EF=25%) and MDCT, EDV and ESV were measured and EF was calculated. Clinical materials consisted of 11 consecutive human subjects who underwent MDCT. MDCT data were acquired during a single breathhold, using an intravenous injection of contrast medium. Left ventriculography (LVG) was performed in all patients as a gold standard. LV-EF was calculated by measuring ESV and EDV in all patients. In the phantom study, LV volumes were: EDV=137 ml, ESV=101 ml, stroke volume=36 ml, and EF=26%. Close correlations were observed between MDCT values and LVG values (EDV: r=0.95, ESV: r=0.98, EF: r=0.93, p<0.001). MDCT was useful for the assessment of LV volumes and EF in various patients with cardiovascular diseases (CVD). (author)

  10. Form reappearance of the section sensitivity profile on Z-axis in multi-detector spiral computed tomography

    The filter is hung in the direction of slice thickness (Z-axis) in the reconstruction of multi-detector spiral CT. Because of this, performing several time scans is considered useful from the standpoint of reappearance of the section sensitivity profile curves. However, when examination is done at full width half maximum (FWHM) and the position of the center of FWHM, there is non-symmetry and the level of hem extent of the section sensitivity profile curves. Change in FWHM and the position of the center of FWHM increases as pitch increases. Although the change in FWHM was less when the reconstruction slice thickness was increased, the change became larger in the center of FWHM as well. As for the non-symmetry of the section sensitivity profile curves and the level of hem extent, the change decreased when the reconstruction slice thickness was increased, although it increased when pitch was enlarged. It is considered that the cause of these changes is change in table movement speed during scanning. (author)

  11. Extremely Rare R-I Subtype Coronary Artery Anomaly and Accompanying Incomplete Myocardial Bridging on the Left Anterior Descending Artery in a Symptomatic Patient: Multidetector Computed Tomography and Coronary Angiography Findings

    Myocardial bridging and single coronary artery (SCA) may both lead to myocardial ischemia and related secondary complications. We present multidetector computed tomography (MDCT) and catheter coronary angiography (CCA) findings of R-I subtype SCA, which is a distinctively rare congenital coronary anomaly, and accompanying incomplete myocardial bridging in a case with dyspnea and chest burning. In addition, CCA showed a thin milking effect at the tunneled artery

  12. Extremely Rare R-I Subtype Coronary Artery Anomaly and Accompanying Incomplete Myocardial Bridging on the Left Anterior Descending Artery in a Symptomatic Patient: Multidetector Computed Tomography and Coronary Angiography Findings

    Koksal, A.; Canyigit, M.; Akgoz, A.; Kaya, D.; Akhan, O. (Dept. of Radiology, Ankara Ataturk Education and Research Hospital, Bilkent, Ankara (Turkey)); Dincer, H. (Dept. of Cardiology, Bayindir Hospital, Sogutozu, Ankara (Turkey))

    2009-08-15

    Myocardial bridging and single coronary artery (SCA) may both lead to myocardial ischemia and related secondary complications. We present multidetector computed tomography (MDCT) and catheter coronary angiography (CCA) findings of R-I subtype SCA, which is a distinctively rare congenital coronary anomaly, and accompanying incomplete myocardial bridging in a case with dyspnea and chest burning. In addition, CCA showed a thin milking effect at the tunneled artery

  13. Multi-Detector Row Computed Tomographic Evaluation of a Rare Type of Complete Vascular Ring: Double Aortic Arch with Atretic Left Arch Distal to the Origin of Left Subclavian Artery

    Hung, Ying-Ying; Fu, Yun-Ching; Wei, Hao-Ji; Tsai, I-Chen; Chen, Clayton Chi-Chang

    2013-01-01

    Double aortic arch with an atretic left arch distal to the origin of left subclavian artery was diagnosed with multi-detector row computed tomography (MDCT) in two children with dysphagia. This rare type of complete vascular ring is clinically important because it may be confused with right aortic arch in mirror imaging. Anatomic details of this rare type of complete vascular ring demonstrated on MDCT facilitated appropriate surgical treatment.

  14. Usefulness of lesion image mapping with multidetector-row helical computed tomography using a dedicated skin marker in breast-conserving surgery

    To investigate the usefulness of computed tomography (CT) with skin-marker placement in determining the excision area and decreasing the positive or close margin rates in breast-conserving surgery (BCS). Multidetector-row helical computed tomography (MDCT) mapping images were reconstructed in subjects (n 117) diagnosed with primary breast cancer who had undergone MDCT using CT skin markers. Serial 5-mm-thick slices prepared from the surgical specimen were used for pathological analyses. A ''positive margin'' was defined as the presence of malignant cells at the surgical margin, and a ''close margin'' as a tumor within 5 mm of the surgical margin. The rates of positive and close margins were calculated. We identified the lesions in 111 of 117 cases (94.9%) on MDCT. Of these, 93 underwent BCS under the guidance of MDCT mapping and the remaining 18 underwent mastectomy. Among the 93 cases, 6 (6.5%) had positive or close margins and were diagnosed with ductal carcinoma in situ of low nuclear grade. MDCT mapping with a CT skin marker is feasible for simulating surgical positioning and determining the excision area. MDCT mapping could decrease the positive and close margin rates in BCS. (orig.)

  15. The feasibility of axial and coronal combined imaging using multi-detector row computed tomography for the diagnosis and treatment of a primary spontaneous pneumothorax

    Kim Do

    2011-05-01

    Full Text Available Abstract Background The preoperative detection of emphysema like changes (ELCs is necessary for the successful treatment of pneumothorax. High resolution computed tomography (HRCT has been used for the preoperative detection of ELCs. However, the traditional HRCT method uses only the axial view, which is perpendicular to the distribution of ELCs. This is not an ideal diagnostic method for the evaluation of ELCs. Methods Forty-eight patients with pneumothorax had multi-detector computed tomography (MDCT reconstruction using the coronal view. ELCs were evaluated in the axial and coronal view by a radiologist. A surgeon performed intra-operative examinations of the ELCs. The sensitivity of the different views was compared. Results The detection sensitivity was 74.4% (70/94 for the axial view and 91.5% (86/94 for the axial-coronal combined view. The intra-operative detection rate was 95.7% (90/94. The preoperative detection of ELCs on the axial-coronal combined view was significantly higher than on the conventional axial view alone (p Conclusions Evaluation of ELCs on the axial and coronal combined HRCT improved the sensitivity of preoperative detection of ELCs compared to the conventional single axial HRCT. This increased sensitivity will help decrease the recurrence with VATS.

  16. Comparison of diagnostic value of multidetector computed tomography and X-ray in the detection of body packing

    Objective: Radiologists and other clinicians are facing an increasing number of illegal drug-related medical conditions. We aimed to draw attention to this growing global problem and to highlight some of the important points related to diagnosis and follow-up of body packing. We compare the diagnostic performance of unenhanced multidetector CT (MDCT) and abdomen X-ray for the detection of drug-filled packets. Materials and methods: Sixty-seven suspects, who underwent both CT and X-ray examinations, have been included in the study. All MDCT and X-ray images were independently and retrospectively reviewed by two observers with different degrees of experience in abdomen imaging. Fifty-two of them were identified as body packers finally. Interobserver agreement, sensitivity, specificity, positive and negative predictive value were calculated. Results: Two types of packets with different characteristics were identified in all body packers. Type 1 packets (solid-state drug) were found in 41 patients and type 2 packets (liquid cocaine) in 11 patients. All statistical analyses concern the detection of any packets. That is, the whole evaluation has been performed per patient. Sensitivity/specificity values of type 1 and type 2 packets for MDCT were 100–98%/100–100% and 100–100%/100–100%, respectively. Besides, sensitivity/specificity values of type 1 and type 2 packets for X-ray were 93–90%/100–91% and 64–45%/73–71%, respectively. In addition, interobserver agreements for detection of any packets were excellent (κ = 0.96) and good (κ = 0.75) for interpretation of MDCT and X-ray, respectively. Conclusion: Unenhanced MDCT is a fast, accurate and easily used diagnostic tool with high sensitivity and specificity for the exact diagnosis of body packing

  17. Comparison of diagnostic value of multidetector computed tomography and X-ray in the detection of body packing

    Bulakci, Mesut, E-mail: mesutbulakci@yahoo.com [Department of Radiology, Haseki Training and Research Hospital, 34096 Aksaray, Istanbul (Turkey); Kalelioglu, Tuba, E-mail: tubakarsakarya@hotmail.com [Department of Radiology, Haseki Training and Research Hospital, 34096 Aksaray, Istanbul (Turkey); Bulakci, Betul Bozkurt, E-mail: dr.betulbozkurt@gmail.com [Department of Family Medicine, Istanbul University, Istanbul Faculty of Medicine, 34390 Capa, Istanbul (Turkey); Kiris, Adem, E-mail: ademkiris@hotmail.com [Department of Radiology, Haseki Training and Research Hospital, 34096 Aksaray, Istanbul (Turkey)

    2013-08-15

    Objective: Radiologists and other clinicians are facing an increasing number of illegal drug-related medical conditions. We aimed to draw attention to this growing global problem and to highlight some of the important points related to diagnosis and follow-up of body packing. We compare the diagnostic performance of unenhanced multidetector CT (MDCT) and abdomen X-ray for the detection of drug-filled packets. Materials and methods: Sixty-seven suspects, who underwent both CT and X-ray examinations, have been included in the study. All MDCT and X-ray images were independently and retrospectively reviewed by two observers with different degrees of experience in abdomen imaging. Fifty-two of them were identified as body packers finally. Interobserver agreement, sensitivity, specificity, positive and negative predictive value were calculated. Results: Two types of packets with different characteristics were identified in all body packers. Type 1 packets (solid-state drug) were found in 41 patients and type 2 packets (liquid cocaine) in 11 patients. All statistical analyses concern the detection of any packets. That is, the whole evaluation has been performed per patient. Sensitivity/specificity values of type 1 and type 2 packets for MDCT were 100–98%/100–100% and 100–100%/100–100%, respectively. Besides, sensitivity/specificity values of type 1 and type 2 packets for X-ray were 93–90%/100–91% and 64–45%/73–71%, respectively. In addition, interobserver agreements for detection of any packets were excellent (κ = 0.96) and good (κ = 0.75) for interpretation of MDCT and X-ray, respectively. Conclusion: Unenhanced MDCT is a fast, accurate and easily used diagnostic tool with high sensitivity and specificity for the exact diagnosis of body packing.

  18. Multidetector-row computed tomography for prosthetic heart valve dysfunction: is concomitant non-invasive coronary angiography possible before redo-surgery?

    Tanis, Wilco [Haga Teaching Hospital, Department of Cardiology, The Hague (Netherlands); Haga Teaching Hospital, The Hague (Netherlands); Sucha, Dominika; Habets, Jesse [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Laufer, Ward; Chamuleau, Steven [University Medical Center Utrecht, Department of Cardiology, Utrecht (Netherlands); Herwerden, Lex.A. van [University Medical Center Utrecht, Department of Cardiothoracic Surgery, Utrecht (Netherlands); Symersky, Petr [Vrije Universiteit, Department of Cardiothoracic Surgery, Amsterdam (Netherlands); Budde, Ricardo P.J. [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands)

    2015-06-01

    Retrospective ECG-gated multidetector-row computed tomography (MDCT) is increasingly used for the assessment of prosthetic heart valve (PHV) dysfunction, but is also hampered by PHV-related artefacts/cardiac arrhythmias. Furthermore, it is performed without nitroglycerine or heart rate correction. The purpose was to determine whether MDCT performed before potential redo-PHV surgery is feasible for concomitant coronary artery stenosis assessment and can replace invasive coronary angiography (CAG). PHV patients with CAG and MDCT were identified. Based on medical history, two groups were created: (I) patients with no known coronary artery disease (CAD), (II) patients with known CAD. All images were scored for the presence of significant (>50 %) stenosis. CAG was the reference test. Fifty-one patients were included. In group I (n = 38), MDCT accurately ruled out significant stenosis in 19/38 (50 %) patients, but could not replace CAG in the remaining 19/38 (50 %) patients due to non-diagnostic image quality (n = 16) or significant stenosis (n = 3) detection. In group II (n = 13), MDCT correctly found no patients without significant stenosis, requiring CAG imaging in all. MDCT assessed patency in 16/19 (84 %) grafts and detected a hostile anatomy in two. MDCT performed for PHV dysfunction assessment can replace CAG (100 % accurate) in approximately half of patients without previously known CAD. (orig.)

  19. Multidetector-row computed tomography-based clinical assessment of fondaparinux for treatment of acute pulmonary embolism and acute deep vein thrombosis in Japanese patients

    Unfractionated heparin (UFH) is the standard drug for the initial treatment of pulmonary embolism (PE) and deep vein thrombosis (DVT) in Japan, whereas fondaparinux is the standard drug in Europe and the United States. Here, we examine the efficacy and safety of fondaparinux in Japanese patients. In 2 randomized, open-label, multicenter studies, 80 Japanese patients with acute PE or DVT received either subcutaneous fondaparinux or intravenous UFH as a non-comparative reference, in a 3:1 ratio, for 5-10 days. Concomitant warfarin therapy was continued until Day 90. Multidetector-row computed tomography-based assessment showed that 57.9% and 45.9% of the patients with acute PE and acute proximal DVT had proximal DVT and PE as a complication, respectively. There was no recurrence of symptomatic venous thromboembolism. In the fondaparinux group, the respective improvement rates at the end of the initial treatment and follow-up periods were 71.4% and 86.8% for 42 patients with PE, and 57.8% and 83.3% for 46 patients with DVT; similar results were noted in the UFH group. One patient in the fondaparinux group experienced major bleeding during the initial treatment, but no such episode in the UFH group. Once-daily, subcutaneous fondaparinux is as effective and safe without monitoring as adjusted-dose intravenous UFH for the initial treatment of acute PE and DVT in Japanese patients. (author)

  20. Contrast enhancement in multidetector-row computed tomography (MDCT) of the abdomen: intraindividual comparison of contrast media containing 300 mg versus 370 mg iodine per ml

    Behrendt, F.F.; Mahnken, A.H.; Keil, S.; Das, M.; Hohl, C.; Guenther, R.W.; Muehlenbruch, G. [University Hospital RWTH Aachen, Department of Diagnostic Radiology, Aachen (Germany); Bauer, D. [University Hospital (RWTH), Institute of Medical Statistics, Aachen (Germany); Seidensticker, P. [Bayer Schering Pharma AG, Berlin (Germany); Jost, E. [University Hospital (RWTH), Medical Clinic IV, Aachen (Germany); Wildberger, J.E. [HELIOS Klinikum Berlin-Buch, Department of Diagnostic Radiology, Berlin (Germany)

    2008-06-15

    The purpose of this study was to intraindividually evaluate the difference in intraluminal vessel and parenchyma contrast enhancement of two different iodine concentrations in multidetector-row computed tomography (MDCT) of the abdomen. Eighty-three patients underwent baseline and follow-up MDCT-scanning (Somatom Sensation 16; Siemens, Forchheim, Germany) of the abdomen using contrast media containing 370 mg iodine/ml (protocol A; Ultravist 370, Bayer Schering Pharma, Berlin, Germany) and 300 mg iodine/ml (protocol B; Ultravist 300). The total iodine load (37 g iodine) and the iodine delivery rate (1.29 g iodine/s) were identical for both protocols. Contrast enhancement in the portal venous phase was measured in the abdominal aorta, inferior vena cava, portal vein, liver, spleen, pancreas and kidney. Mean attenuation values were compared using paired t-test. Intraindividual comparison revealed no statistically significant differences of the mean attenuation values between protocols A and B for all anatomic sites: abdominal aorta, inferior vena cava, portal vein, liver, spleen, pancreas and kidney (all P > 0.05). Given an injection protocol with constant total iodine load and constant iodine delivery rate, the iodine concentration of contrast media does not significantly influence abdominal contrast enhancement in the portal venous phase. (orig.)

  1. Contrast enhancement in multidetector-row computed tomography (MDCT) of the abdomen: intraindividual comparison of contrast media containing 300 mg versus 370 mg iodine per ml

    The purpose of this study was to intraindividually evaluate the difference in intraluminal vessel and parenchyma contrast enhancement of two different iodine concentrations in multidetector-row computed tomography (MDCT) of the abdomen. Eighty-three patients underwent baseline and follow-up MDCT-scanning (Somatom Sensation 16; Siemens, Forchheim, Germany) of the abdomen using contrast media containing 370 mg iodine/ml (protocol A; Ultravist 370, Bayer Schering Pharma, Berlin, Germany) and 300 mg iodine/ml (protocol B; Ultravist 300). The total iodine load (37 g iodine) and the iodine delivery rate (1.29 g iodine/s) were identical for both protocols. Contrast enhancement in the portal venous phase was measured in the abdominal aorta, inferior vena cava, portal vein, liver, spleen, pancreas and kidney. Mean attenuation values were compared using paired t-test. Intraindividual comparison revealed no statistically significant differences of the mean attenuation values between protocols A and B for all anatomic sites: abdominal aorta, inferior vena cava, portal vein, liver, spleen, pancreas and kidney (all P > 0.05). Given an injection protocol with constant total iodine load and constant iodine delivery rate, the iodine concentration of contrast media does not significantly influence abdominal contrast enhancement in the portal venous phase. (orig.)

  2. Prone position is essential for detection of pulmonary vein pseudostenosis by enhanced multidetector computed tomography in patients who undergo pulmonary vein isolation

    Pulmonary vein (PV) stenosis is a major complication of PV isolation (PVI) by catheter ablation, so in the present study the optimal position for detecting PV stenosis on enhanced multidetector computed tomography (MDCT) image acquisition was determined. The 64-slice enhanced MDCT was carried out before and after PVI in 116 consecutive patients with atrial fibrillation while they were in the prone position, as well as while supine. The supine position MDCT image showed >50% diameter stenosis of the PV in 11 (9%) patients before PVI (% diameter stenosis: mean 55±4%, range 51-65%). Greater than 50% diameter stenosis was seen in the left inferior PV in all 11 patients. The prone position attenuated the PV stenosis findings in the MDCT images in all 11 patients (mean 9±6%, range 2-18%). Stenosis visualized on images acquired in the supine position was, therefore, concluded to be pseudostenosis caused by descending aorta compression. At 3 months after PVI, no significant changes in PV diameter were observed in these 11 patients. The present study demonstrated that the prone position is essential for eliminating PV pseudostenosis observed on supine-position enhanced MDCT images. The results also indicate that preexisting PV organic stenosis is rare. (author)

  3. Value of virtual tracheobronchoscopy and bronchography from 16-slice multidetector-row spiral computed tomography for assessment of suspected tracheobronchial stenosis in children

    Honnef, Dagmar; Wildberger, Joachim E.; Das, Marco; Hohl, Christian; Mahnken, Andreas H.; Guenther, Rolf W.; Staatz, Gundula [University Hospital RWTH Aachen, Department of Diagnostic Radiology, Aachen (Germany); Barker, Michael [University Hospital RWTH Aachen, Department of Pediatrics, Aachen (Germany)

    2006-08-15

    To evaluate the value of dose-reduced 16-slice multidetector-row spiral computed tomography (16-MDCT) using virtual tracheobronchoscopy (VTB) and virtual bronchography (VBG) in children with suspected tracheobronchial stenosis. 12 children (4 d to 3 years, body weight 1.2 kg to 13.5 kg) with stridor and suspected tracheobronchial stenosis were examined by contrast-enhanced low-dose 16-MDCT. Conventional axial slices, MPRs, VTB, and VBG were calculated. Image findings were correlated with the results of fiberoptic bronchoscopy (12 out of 12) as a gold standard and subsequent surgery (8 out of 12). VTB and VBG demonstrated the fiberoptic bronchoscopically suspected tracheal stenosis in 11 of 12 children due to vascular compression because of the brachiocephalic trunk (6), a double aortic arch (2), a vascular compression of the left main bronchus (2), and a right aberrant subclavian artery (1). Eleven out of 12 stenoses were correctly depicted by conventional axial slices, MPRs, VTB, and VBG. Dose reduction was 79 to 85.8% compared to a standard adult chest CT. Dose-reduced 16-MDCT with the use of VTB and VBG is effective for the evaluation of tracheobronchial stenosis in children and correlates well with fiberoptic bronchoscopy. (orig.)

  4. Evaluation of pulmonary artery branching patterns in the right upper lobe of the lung from multiplanar reconstruction images using multidetector-row computed tomography

    Multidetector-row computed tomography (MDCT) allows the high resolution multi-planar reconstruction (MPR) of images taken in the coronal, sagittal and axial planes. The purpose of this study was to evaluate the branching patterns of the A3a pulmonary artery in the right upper lobe from MPR images, and to assess the MDCT protocol and analysis method. The 32 cases studied comprised 30 patients with known or suspected disease of the lung parenchyma and 2 healthy volunteers. An MDCT scanner, Aquilion (Toshiba, Tokyo, Japan), was used for pulmonary imaging. Coronal and sagittal images were reconstructed from the axial scans at 2-mm intervals. The arterial variations of A3ai and A3aii, arising from either the superior trunk or the ascending artery (a branch of the inferior trunk) were evaluated. A3ai was found to originate from the superior trunk in 31 subjects (96.9%) and from the ascending artery in one subject (3.1%), whereas A3aii originated from the superior trunk in 12 subjects (62.5%) and from the ascending artery in 12 (37.5%). High resolution MPR images can provide a means of assessing the arterial branching pattern at the level of the sub-segmental pulmonary artery. (author)

  5. Multidetector-row computed tomography for prosthetic heart valve dysfunction: is concomitant non-invasive coronary angiography possible before redo-surgery?

    Retrospective ECG-gated multidetector-row computed tomography (MDCT) is increasingly used for the assessment of prosthetic heart valve (PHV) dysfunction, but is also hampered by PHV-related artefacts/cardiac arrhythmias. Furthermore, it is performed without nitroglycerine or heart rate correction. The purpose was to determine whether MDCT performed before potential redo-PHV surgery is feasible for concomitant coronary artery stenosis assessment and can replace invasive coronary angiography (CAG). PHV patients with CAG and MDCT were identified. Based on medical history, two groups were created: (I) patients with no known coronary artery disease (CAD), (II) patients with known CAD. All images were scored for the presence of significant (>50 %) stenosis. CAG was the reference test. Fifty-one patients were included. In group I (n = 38), MDCT accurately ruled out significant stenosis in 19/38 (50 %) patients, but could not replace CAG in the remaining 19/38 (50 %) patients due to non-diagnostic image quality (n = 16) or significant stenosis (n = 3) detection. In group II (n = 13), MDCT correctly found no patients without significant stenosis, requiring CAG imaging in all. MDCT assessed patency in 16/19 (84 %) grafts and detected a hostile anatomy in two. MDCT performed for PHV dysfunction assessment can replace CAG (100 % accurate) in approximately half of patients without previously known CAD. (orig.)

  6. Quantitative assessment of lung volumes using multi-detector row computed tomography (MDCT) in patients with chronic obstructive pulmonary disease (COPD)

    To evaluate the clinical value of the multi-detector row computed tomography (MDCT) in the quantitative assessment of lung volumes and to assess the relationship between the MDCT results and disease severity as determined by a pulmonary function test (PFT) in Chronic Obstructive Pulmonary Disease (COPD) patients. We performed a PFT and MDCT on 39 COPD patients. Using the GOLD classifications, we divided the patients into three groups according to disease severity; stage I (mild, n = 10), stage II (moderate, n = 15), and stage III (severe, n = 14). Using the pulmo-CT software program, we measured the proportion of lung volumes with attenuation values below -910 and -950 HU. The mean FEV1 (% of predicted) and FEV1/FVC was 82.2 ± 2% and 66.2 ± 3% in stage I, 53.5 ± 11% and 52 ± 6% in stage II, and 32.3 ± 7% and 44.2% ± 13% in stage III, respectively. Differences in lung volume percentage at each of the thresholds (-910 and -950 HU) among the 3 stages were statistically significant (ρ < 0.01, ρ < 0.01) and correlated well with the FEV1 and FEV1/FVC (r = -0.803, r -0.766, r = -0.817, and r = -0.795, respectively). The volumetric measurement obtained by MDCT provides an accurate means of quantifying pulmonary emphysema

  7. Quantitative assessment of lung volumes using multi-detector row computed tomography (MDCT) in patients with chronic obstructive pulmonary disease (COPD)

    Lee, Sang Min; Hur, Jin; Kim, Tae Hoon; Kim, Sang Jin; Kim, Hyung Jung [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2008-08-15

    To evaluate the clinical value of the multi-detector row computed tomography (MDCT) in the quantitative assessment of lung volumes and to assess the relationship between the MDCT results and disease severity as determined by a pulmonary function test (PFT) in Chronic Obstructive Pulmonary Disease (COPD) patients. We performed a PFT and MDCT on 39 COPD patients. Using the GOLD classifications, we divided the patients into three groups according to disease severity; stage I (mild, n = 10), stage II (moderate, n = 15), and stage III (severe, n = 14). Using the pulmo-CT software program, we measured the proportion of lung volumes with attenuation values below -910 and -950 HU. The mean FEV1 (% of predicted) and FEV1/FVC was 82.2 {+-} 2% and 66.2 {+-} 3% in stage I, 53.5 {+-} 11% and 52 {+-} 6% in stage II, and 32.3 {+-} 7% and 44.2% {+-} 13% in stage III, respectively. Differences in lung volume percentage at each of the thresholds (-910 and -950 HU) among the 3 stages were statistically significant ({rho} < 0.01, {rho} < 0.01) and correlated well with the FEV1 and FEV1/FVC (r = -0.803, r -0.766, r = -0.817, and r = -0.795, respectively). The volumetric measurement obtained by MDCT provides an accurate means of quantifying pulmonary emphysema.

  8. Sex-specific biatrial volumetric measurements obtained with use of multidetector computed tomography in subjects with and without coronary artery disease.

    Budoff, Matthew J; Pagali, Sandeep R; Hamirani, Yasmin S; Chen, Andy; Cheu, Gordon; Gao, Yanlin; Li, Dong; Mao, SongShou

    2014-06-01

    Atrial volumetric measurement has proven clinical implications. Advances in cardiac imaging, notably the precision enabled by multidetector computed tomography (MDCT), herald the need for new criteria of what constitutes normal volumetric measurements. With use of 64-slice MDCT, we compared the atrial volumes in healthy individuals with those in individuals with coronary artery disease. By means of manual segmentation, we measured biatrial volume in 686 participants who underwent retrospective electrocardiographic-gated MDCT angiographic evaluation. The study population included a control group of 203 persons with no cardiac abnormalities, and a study group of 483 patients with obstructive coronary artery disease. All variables were compared between men and women and between the groups. We found a significant difference in left atrial end-systolic and end-diastolic volumes between men and women in the control group (P <0.05); however, right atrial volumes were similar. In comparison with the entire control group, the coronary artery disease group had significantly higher left atrial volume, significantly lower right atrial stroke volume, and significantly lower biatrial ejection fraction, except for left atrial ejection fraction in men. Right atrial volume and left atrial stroke volume were not significantly different. The results imply that a sex-specific reference value is necessary for left atrial volumetric evaluation, and that left atrial volume and biatrial ejection fraction (excluding left atrial ejection fraction in men) might be useful during diagnosis and prognosis in patients who have coronary artery disease. PMID:24955043

  9. Lung MRI of invasive fungal infection at 3 Tesla: evaluation of five different pulse sequences and comparison with multidetector computed tomography (MDCT)

    Yan, Chenggong; Tan, Xiangliang; Li, Caixia; Wu, Yuankui; Hao, Peng; Xiong, Wei; Xu, Yikai [Southern Medical University, Department of Medical Imaging Center, Nanfang Hospital, Guangzhou, Guangdong (China); Wei, Qi; Feng, Ru; Xu, Jun [Southern Medical University, Department of Hematology, Nanfang Hospital, Guangzhou (China); Chan, Queenie [Philips Healthcare, New Territories (China)

    2014-09-18

    To evaluate the diagnostic performance of five MR sequences to detect pulmonary infectious lesions in patients with invasive fungal infection (IFI), using multidetector computed tomography (MDCT) as the reference standard. Thirty-four immunocompromised patients with suspected IFI underwent MDCT and MRI. The MR studies were performed using five pulse sequences at 3.0 T: T2-weighted turbo spin echo (TSE), short-tau inversion recovery (STIR), spectrally selective attenuated inversion recovery (SPAIR), T1-weighted high resolution isotropic volume excitation (e-THRIVE) and T1-weighted fast field echo (T1-FFE). The size, lesion-to-lung contrast ratio and the detectability of pulmonary lesions on MR images were assessed. Image quality and artefacts on different sequences were also rated. A total of 84 lesions including nodules (n = 44) and consolidation (n = 40) were present in 75 lobes. SPAIR and e-THRIVE images achieved high overall lesion-related sensitivities for the detection of pulmonary abnormalities (90.5 % and 86.9 %, respectively). STIR showed the highest lesion-to-lung contrast ratio for nodules (21.8) and consolidation (17.0), whereas TSE had the fewest physiological artefacts. MRI at 3.0 T can depict clinically significant pulmonary IFI abnormalities with high accuracy compared to MDCT. SPAIR and e-THRIVE are preferred sequences for the detection of infectious lesions of 5 mm and larger. (orig.)

  10. Lung MRI of invasive fungal infection at 3 Tesla: evaluation of five different pulse sequences and comparison with multidetector computed tomography (MDCT)

    To evaluate the diagnostic performance of five MR sequences to detect pulmonary infectious lesions in patients with invasive fungal infection (IFI), using multidetector computed tomography (MDCT) as the reference standard. Thirty-four immunocompromised patients with suspected IFI underwent MDCT and MRI. The MR studies were performed using five pulse sequences at 3.0 T: T2-weighted turbo spin echo (TSE), short-tau inversion recovery (STIR), spectrally selective attenuated inversion recovery (SPAIR), T1-weighted high resolution isotropic volume excitation (e-THRIVE) and T1-weighted fast field echo (T1-FFE). The size, lesion-to-lung contrast ratio and the detectability of pulmonary lesions on MR images were assessed. Image quality and artefacts on different sequences were also rated. A total of 84 lesions including nodules (n = 44) and consolidation (n = 40) were present in 75 lobes. SPAIR and e-THRIVE images achieved high overall lesion-related sensitivities for the detection of pulmonary abnormalities (90.5 % and 86.9 %, respectively). STIR showed the highest lesion-to-lung contrast ratio for nodules (21.8) and consolidation (17.0), whereas TSE had the fewest physiological artefacts. MRI at 3.0 T can depict clinically significant pulmonary IFI abnormalities with high accuracy compared to MDCT. SPAIR and e-THRIVE are preferred sequences for the detection of infectious lesions of 5 mm and larger. (orig.)

  11. Incidence of tracheobronchomalacia associated with pulmonary emphysema. Detection with paired inspiratory-expiratory multidetector computed tomography using a low-dose technique

    The purpose of this study was to evaluate the frequency of tracheobronchomalacia (TBM) associated with pulmonary emphysema with paired inspiratory-expiratory multidetector computed tomography (MDCT) using a low-dose technique. This study included 56 consecutive patients (55 men, 1 woman; mean age 68.9 years) with pulmonary emphysema who had undergone paired inspiratory-expiratory CT scanning with a low-dose technique (40 mA). All images were retrospectively examined by two thoracic radiologists in a blinded fashion. The diagnosis of TBM was based on the standard criterion of >50% reduction in the cross-sectional area of the tracheobronchial lumen at the end-expiratory phase. A mild TBM criterion of >30% reduction was also reviewed. All patients underwent pulmonary function tests. The relation between the forced expiratory volume in 1 s (FEV1.0%) and TBM was statistically analyzed. Four (7.1%) and eight (14.3%) patients were diagnosed as TBM based on the standard and mild criteria, respectively. In four patients, the percentages of luminal narrowing were 63.4% and 51.2%, respectively for tracheomalacia and 59.2% and 62.0%, respectively, for bronchomalacia. The FEV1.0% values between patients with and without TBM showed no statistical difference. The incidence of TBM associated with pulmonary emphysema was 7.1% with the standard criterion. It is possible that TBM has been underdiagnosed in a number of patients with pulmonary emphysema. (author)

  12. Magnetic Resonance Enterography Findings in Crohn′s disease in the Pediatric Population and Correlation with Fluoroscopic and Multidetector Computed Tomographic Techniques

    Parul Patel

    2011-01-01

    Full Text Available Traditionally, fluoroscopic examinations such as enteroclysis, upper GI studies, and small bowel follow through exams have been the procedures of choice in evaluating inflammatory bowel disease (IBD in pediatric populations. With the advent of multidetector computed tomography (MDCT, it has subsequently become a complementary examination in imaging inflammatory bowel disease. A major advantage of MDCT over fluoroscopic examination is its ability to directly visualize bowel mucosa, as well as demonstrate extra-enteric complications of IBD such as abscesses, fistulae, and sinus tracts. The major disadvantage of CT however is exposure to ionizing radiation, especially in IBD patients of the pediatric age group who maybe repeatedly imaged due to exacerbations. As a result, magnetic resonance enterography (MRE is becoming increasingly important in the evaluation and follow-up of pediatric patients with IBD. This pictorial essay will summarize the multi-modality imaging findings of IBD with emphasis on MRE including the imaging protocol and procedure. For the purposes of this article, patients less than 17 years of age have been considered to represent the pediatric population.

  13. Clinical and prognostic significance of bone marrow abnormalities in the appendicular skeleton detected by low-dose whole-body multidetector computed tomography in patients with multiple myeloma

    Clinical significance of medullary abnormalities in the appendicular skeleton (AS) detected by low-dose whole-body multidetector computed tomography (MDCT) in patients with multiple myeloma (MM) was investigated. A total of 172 patients with monoclonal gammopathy of undetermined significance (MGUS) (n=17), smoldering MM (n=47) and symptomatic MM (n=108) underwent low-dose MDCT. CT values (CTv) of medullary density of AS⩾0 Hounsfield unit (HU) was considered as abnormal. Percentage of medullary abnormalities and the mean CTv of AS in patients with MGUS, smoldering MM and symptomatic MM were 18, 55 and 62% and −44.5 , −20.3 and 11.2 HU, respectively (P<0.001 and P<0.001). Disease progression of MM was independently associated with high CTv on multivariate analysis. In symptomatic MM, the presence of abnormal medullary lesions was associated with increased incidence of high-risk cytogenetic abnormalities (34.4% vs 7.7% P=0.002) and extramedullary disease (10.4% vs 0% P=0.032). It was also an independent poor prognostic predictor (hazard ratio 3.546, P=0.04). This study showed that CTv of AS by MDCT is correlated with disease progression of MM, and the presence of abnormal medullary lesions is a predictor for poor survival

  14. The effectiveness of postmortem multidetector computed tomography in the detection of fatal findings related to cause of non-traumatic death in the emergency department

    Takahashi, Naoya; Higuchi, Takeshi; Shiotani, Motoi [Niigata City General Hospital, Department of Diagnostic Radiology, Niigata, Niigata (Japan); Hirose, Yasuo [Niigata City General Hospital, Department of Emergency and Critical Care, Niigata (Japan); Shibuya, Hiroyuki; Hashidate, Hideki [Niigata City General Hospital, Department of Pathology, Niigata (Japan); Yamanouchi, Haruo; Funayama, Kazuhisa [Niigata University Graduate School of Medical and Dental Sciences, Department of Community Preventive Medicine, Division of Legal Medicine, Niigata (Japan)

    2012-01-15

    To investigate the diagnostic performance of postmortem multidetector computed tomography (PMMDCT) for the detection of fatal findings related to causes of non-traumatic death in the emergency department (ED). 494 consecutive cases of clinically diagnosed non-traumatic death in ED involving PMMDCT were enrolled. The fatal findings were detected on PMMDCT and classified as definite or possible findings. These findings were confirmed by autopsy in 20 cases. The fatal findings were detected in 188 subjects (38.1%) including 122 with definite (24.7%) and 66 with possible finding (13.4%). Definite findings included 21 cases of intracranial vascular lesions, 84 with intra-thoracic haemorrhage, 13 with retroperitoneal haemorrhage and one with oesophagogastric haemorrhage. In three patients who had initially been diagnosed with non-traumatic death, PMMDCT revealed fatal traumatic findings. Two definite findings (two haemopericardiums) and seven possible findings (two intestinal obstructions, one each of multiple liver tumours central pulmonary artery dilatation, pulmonary congestion, peritoneal haematoma, and brain oedema) were confirmed by autopsy. The causes of death were not determined in cases with possible findings without autopsy. PMMDCT is a feasible tool for detecting morphological fatal findings in non-traumatic death in ED. It is important to know the ability and limitation of PMMDCT. (orig.)

  15. Non-obstructive low attenuation coronary plaque predicts three-year acute coronary syndrome events in patients with hypertension. Multidetector computed tomographic study

    Arterial hypertension is an established risk factor for acute coronary syndrome (ACS). Multidetector computed tomography (MDCT) is an accurate and less invasive technique for assessment of the degree of coronary artery luminal narrowing and characterization of coronary atherosclerosis. We therefore aimed to investigate the predictive power of MDCT for future ACS events and compared with traditional parameters in patients with hypertension. One hundred and thirty-four patients (93 men, mean age 70±11 years) with hypertension underwent MDCT for evaluation of coronary artery disease. MDCT analysis focused on the presence of plaques, the degree of stenosis, and the plaque characteristics. Traditional parameters included Framingham risk score, carotid intima-media thickness, and left ventricular mass index. During a mean follow-up of 39±10 months, ACS events occurred in 10 patients, including myocardial infarction (n=3) and unstable angina (n=7). Multivariate analysis identified total number of low attenuation plaques as an independent predictor of ACS events (p<0.001). We demonstrated that non-obstructive low attenuation coronary plaques on MDCT predicted more accurately future ACS events in patients with hypertension than traditional parameters. (author)

  16. A model for temporal resolution of multidetector computed tomography of coronary arteries in relation to rotation time, heart rate and reconstruction algorithm

    Greuter, M.J.W.; Ooijen, P.M.A. van; Oudkerk, M. [University Medical Center Groningen, University of Groningen, Department of Radiology, P.O. Box 30.001, Groningen (Netherlands); Flohr, T. [Siemens Medical Solutions, CT Division, Forchheim (Germany)

    2007-03-15

    A model is presented that describes the image quality of coronary arteries with multidetector computer tomography. The results are discussed in the context of rotation time of the scanner, heart rate, and number of sectors used in the acquisition process. The blurring of the coronary arteries was calculated for heart rates between 50 and 100 bpm for rotation times of 420, 370, and 330 ms, and one-, two-, three-, and four-sector acquisition modes and irregular coronary artery movement is included. The model predicts optimal timing within the RR cycle of 45{+-}3% (RCA), 44{+-}4% and 74{+-}6% (LCX), and 35{+-}4% and 76{+-}5% (LAD). The optimal timing shows a negative linear dependency on heart rate and increases with the number of sectors used. The RCA blurring decreases from 0.98 cm for 420 ms, one-sector mode to 0.27 cm for 330 ms, four-sector mode. The corresponding values are 0.81 cm and 0.29 cm for LCX and 0.42 cm and 0.17 cm for LAD. The number of sectors used in a multisector reconstruction and the timing within the cardiac cycle should be adjusted to the specific coronary artery that has to be imaged. Irregular coronary artery movement of 1.5 mm justifies the statement that no more than two sectors should be used in multisector acquisition processes in order to improve temporal resolution in cardiac MDCT. (orig.)

  17. Multi-detector computed tomography is equivalent to trans-oesophageal echocardiography for the assessment of the aortic annulus before transcatheter aortic valve implantation

    In transcatheter aortic valve implantation (TAVI), assessment of the aortic annulus is mandatory. We sought to investigate the correlation between trans-oesophageal echocardiography (TEE) and multi-detector computed tomography (MDCT) for annulus diameter assessment before TAVI. A total of 122 patients (67 male, mean age 84 ± 6 years) underwent MDCT and TEE for TAVI planning. In TEE annulus diameters were obtained in a long-axis view at diastole. MDCT data were evaluated using MPR images, and corresponding projections were adjusted for MDCT and TEE. Patients were classified by the predominant localisation of aortic valve calcifications, and annulus diameters between TEE and MDCT were correlated. Additionally, the eccentricity of the aortic annulus was calculated. Mean eccentricity of the aortic annulus determined by MDCT was 0.34 ± 0.17, with no difference according to valve calcification. Regarding the aortic annulus diameter, the mean values measured were 24.3 ± 2.1 mm in MDCT and 24.0 ± 2.5 mm in TEE (P < 0.0001 for agreement). Independent of the pattern of aortic valve calcification, close correlation is found between CT and TEE measurements of the aortic annulus diameter. In addition, CT demonstrates the non-circular shape of the aortic annulus. (orig.)

  18. Sixteen multidetector row computed tomography of pulmonary veins: 3-months' follow-up after treatment of paroxysmal atrial fibrillation with cryothermal ablation

    The aim of the study was to assess pulmonary veins (PVs) for the presence of stenosis 3 months after cryothermal ablation (CA) with a new method of electrical isolation of PVs using contrast-enhanced 16 multidetector row computed tomography (MDCT). Twenty four patients with symptomatic atrial fibrillation underwent CA in 46 PVs. MDCT of PVs was performed before the treatment and after 3-months' follow-up. Following cryoablation, 13/24 (54%) patients showed clinical improvement and had reduced attacks of atrial fibrillation. The dimensions of the treated PVs remained unchanged: the coronal ostial diameter was 19.1±2.4 preprocedural versus 18.6±2.4 mm at follow-up, p>0.05; the ratio of the coronal and axial diameters at the ostium was 1.2±0.2 versus 1.2±0.1, p>0.05, respectively, and the coronal diameter of the proximal 10 mm was 17.1±2.5 mm versus 16.5±2.2 mm, p>0.05, respectively. CA is a promising technique for electrical isolation of PVs that has not been associated with stenosis at the orifice and the proximal 10 mm of the PVs after 3-months' follow-up. MDCT is a noninvasive, fast and comfortable method for assessment of PVs in a three-dimensional manner prior to ablative treatment and during the follow-up. (orig.)

  19. Right atrial volume calculated by multi-detector computed tomography. Useful predictor of atrial fibrillation recurrence after pulmonary vein catheter ablation

    We investigated whether right atrial (RA) volume could be used to predict the recurrence of atrial fibrillation (AF) after pulmonary vein catheter ablation (CA). We evaluated 65 patients with paroxysmal AF (mean age, 60+10 years, 81.5% male) and normal volunteers (57±14 years, 41.7% male). Sixty-four-slice multi-detector computed tomography was performed for left atrial (LA) and RA volume estimations before CA. The recurrence of AF was assessed for 6 months after the ablation. Both left and right atrial volumes were larger in the AF patients than the normal volunteers (LA: 99.7+33.2 ml vs. 59.7+17.4 ml; RA: 82.9+35.7 ml vs. 43.9+12 ml; P100 ml) for predicting the recurrence of AF was 81.3% in 13 of 16 patients with AF recurrence, and the specificity was 69.4% in 34 of 49 patients without recurrence. The sensitivity with large RA volumes (>87 ml) was 81.3% in 13 of 16 patients with AF recurrence, and the specificity was 75.5% in 37 of 49 patients without recurrence. RA volume is a useful predictor of the recurrence of AF, similar to LA volume. (author)

  20. Sixteen multidetector row computed tomography of pulmonary veins: 3-months' follow-up after treatment of paroxysmal atrial fibrillation with cryothermal ablation

    Maksimovic, Ruzica; Cademartiri, Filippo; Pattynama, Peter M.T. [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands); Scholten, Marcoen F.; Jordaens, Luc J. [Erasmus Medical Center, Department of Cardiology, Rotterdam (Netherlands)

    2005-06-01

    The aim of the study was to assess pulmonary veins (PVs) for the presence of stenosis 3 months after cryothermal ablation (CA) with a new method of electrical isolation of PVs using contrast-enhanced 16 multidetector row computed tomography (MDCT). Twenty four patients with symptomatic atrial fibrillation underwent CA in 46 PVs. MDCT of PVs was performed before the treatment and after 3-months' follow-up. Following cryoablation, 13/24 (54%) patients showed clinical improvement and had reduced attacks of atrial fibrillation. The dimensions of the treated PVs remained unchanged: the coronal ostial diameter was 19.1{+-}2.4 preprocedural versus 18.6{+-}2.4 mm at follow-up, p>0.05; the ratio of the coronal and axial diameters at the ostium was 1.2{+-}0.2 versus 1.2{+-}0.1, p>0.05, respectively, and the coronal diameter of the proximal 10 mm was 17.1{+-}2.5 mm versus 16.5{+-}2.2 mm, p>0.05, respectively. CA is a promising technique for electrical isolation of PVs that has not been associated with stenosis at the orifice and the proximal 10 mm of the PVs after 3-months' follow-up. MDCT is a noninvasive, fast and comfortable method for assessment of PVs in a three-dimensional manner prior to ablative treatment and during the follow-up. (orig.)

  1. Multidetector row computed tomography of acute pancreatitis: Utility of single portal phase CT scan in short-term follow up

    Kwon, Yongwonn [Department of Radiology, Konkuk University Medical Center, 4-12, Hwayang-dong, Gwangjin-gu, Seoul 143-729 (Korea, Republic of); Park, Hee Sun, E-mail: heesun.park@gmail.com [Department of Radiology, Konkuk University Medical Center, 4-12, Hwayang-dong, Gwangjin-gu, Seoul 143-729 (Korea, Republic of); Kim, Young Jun; Jung, Sung Il; Jeon, Hae Jeong [Department of Radiology, Konkuk University Medical Center, 4-12, Hwayang-dong, Gwangjin-gu, Seoul 143-729 (Korea, Republic of)

    2012-08-15

    Objective: The purpose of this study is to evaluate the question of whether nonenhanced CT or contrast enhanced portal phase CT can replace multiphasic pancreas protocol CT in short term monitoring in patients with acute pancreatitis. Materials and methods: This retrospective study was approved by the Institutional Review Board. From April 2006 to May 2010, a total of 52 patients having acute pancreatitis who underwent initial dual phase multidetector row CT (unenhanced, arterial, and portal phase) at admission and a short term (within 30 days) follow up dual phase CT (mean interval 10.3 days, range 3-28 days) were included. Two abdominal radiologists performed an independent review of three sets of follow up CT images (nonenhanced scan, single portal phase scan, and dual phase scan). Interpretation of each image set was done with at least 2-week interval. Radiologists evaluated severity of acute pancreatitis with regard to pancreatic inflammation, pancreatic necrosis, and extrapancreatic complication, based on the modified CT severity index. Scores of each image set were compared using a paired t-test and interobserver agreement was evaluated using intraclass correlation coefficient statistics. Results: Mean scores of sum of CT severity index on nonenhanced scan, portal phase scan, and dual phase scan were 5.7, 6.6, and 6.5 for radiologist 1, and 5.0, 5.6, and 5.8 for radiologist 2, respectively. In both radiologists, contrast enhanced scan (portal phase scan and dual phase scan) showed significantly higher severity score compared with that of unenhanced scan (P < 0.05), while portal phase and dual phase scan showed no significant difference each other. The trend was similar regarding pancreatic inflammation and extrapancreatic complications, in which contrast enhanced scans showed significantly higher score compared with those of unenhanced scan, while no significant difference was observed between portal phase scan and dual phase scan. In pancreatic necrosis

  2. Multidetector row computed tomography of acute pancreatitis: Utility of single portal phase CT scan in short-term follow up

    Objective: The purpose of this study is to evaluate the question of whether nonenhanced CT or contrast enhanced portal phase CT can replace multiphasic pancreas protocol CT in short term monitoring in patients with acute pancreatitis. Materials and methods: This retrospective study was approved by the Institutional Review Board. From April 2006 to May 2010, a total of 52 patients having acute pancreatitis who underwent initial dual phase multidetector row CT (unenhanced, arterial, and portal phase) at admission and a short term (within 30 days) follow up dual phase CT (mean interval 10.3 days, range 3–28 days) were included. Two abdominal radiologists performed an independent review of three sets of follow up CT images (nonenhanced scan, single portal phase scan, and dual phase scan). Interpretation of each image set was done with at least 2-week interval. Radiologists evaluated severity of acute pancreatitis with regard to pancreatic inflammation, pancreatic necrosis, and extrapancreatic complication, based on the modified CT severity index. Scores of each image set were compared using a paired t-test and interobserver agreement was evaluated using intraclass correlation coefficient statistics. Results: Mean scores of sum of CT severity index on nonenhanced scan, portal phase scan, and dual phase scan were 5.7, 6.6, and 6.5 for radiologist 1, and 5.0, 5.6, and 5.8 for radiologist 2, respectively. In both radiologists, contrast enhanced scan (portal phase scan and dual phase scan) showed significantly higher severity score compared with that of unenhanced scan (P < 0.05), while portal phase and dual phase scan showed no significant difference each other. The trend was similar regarding pancreatic inflammation and extrapancreatic complications, in which contrast enhanced scans showed significantly higher score compared with those of unenhanced scan, while no significant difference was observed between portal phase scan and dual phase scan. In pancreatic necrosis

  3. Xenon/CT blood flow mapping of the liver using multidetector-row computed tomography. Compensation of respiratory misregistration by volume data

    For improvement in the accuracy of xenon/CT blood flow mapping of the liver, this study was conducted to assess whether volume-data obtained by multidetector-row helical CT could compensate for the slice misregistration caused by inconstant breath depth. Using imaging phantoms scanned on both multidetector-row and single-detector CT, suitable parameters were decided. In the phantom studies, axial scan with multidetector-row CT showed significantly greater variance of CT value than that of single detector row CT (SDCT). On multidetector-row CT, variances of the CT values maintained in low (80 kV) tube voltage, which is advantageous for detecting subtle enhancement of the liver. Images reconstructed with 10-mm thickness showed smaller variance than those of 5-mm thickness on low-pitch helical scan. Remarkable helical artifacts were seen on the high-pitch helical scan. Following the phantom studies, 7 examinees were scanned using xenon/CT with a predetermined scan protocol (80 kV, collimation 5 mm, thickness 10 mm, low-pitch helical scan). In all cases, slice compensation was necessary and was successfully performed. The number of pixels which constituted blood flow map increased after the compensation. No patients showed any significant adverse effects. In conclusion, multidetector-row helical CT has the potential for providing accurate quantification of xenon/CT blood flow mapping of liver by compensating for respiratory misregistration. (author)

  4. Epicardial adipose tissue and pericoronary fat thickness measured with 64-multidetector computed tomography: potential predictors of the severity of coronary artery disease

    Objective: the aim of the present study was to investigate the relationship between pericoronary fat and the severity and extent of atherosclerosis, quantified using 64-multidetector computed tomography, in patients with suspected coronary artery disease. Methods: the study population consisted of 131 patients who were clinically referred for noninvasive multislice computed tomography coronary angiography for the evaluation of coronary artery disease. Patients were classified as follows: no atherosclerosis, Group 1; nonobstructive atherosclerosis (luminal narrowing < 50% in diameter), Group 2; and obstructive atherosclerosis (luminal narrowing ≧ 50%) in a single vessel or obstructive atherosclerosis in the left main coronary artery and/or multiple vessels, Group 3. Epicardial adipose tissue was defined as the adipose tissue between the surface of the heart and the visceral layer of the pericardium (visceral epicardium). Epicardial adipose tissue thickness (mm) was determined in the right ventricular anterior free wall. The mean thickness of the pericoronary fat surrounding the three coronary arteries was used for the analyses. Results: the average thickness over all three regions was 13.2 ± 2.1 mm. The pericoronary fat thickness was significantly increased in Group 3 compared with Groups 2 and 1. The epicardial adipose tissue thickness was significantly increased in Group 3 compared with Groups 2 and 1. A receiver operating characteristic curve for obstructive coronary artery disease was assessed to verify the optimum cut-off point for pericoronary fat thickness, which was 13.8 mm. A receiver operating characteristic curve for obstructive coronary artery disease was also assessed to verify the optimum cut-off point for epicardial adipose tissue, which was 6.8 cm. Conclusion: we showed that the epicardial adipose tissue and pericoronary fat thickness scores were higher in patients with obstructive coronary artery diseases. (author)

  5. Epicardial adipose tissue and pericoronary fat thickness measured with 64-multidetector computed tomography: potential predictors of the severity of coronary artery disease

    Demircelik, Muhammed Bora; Gurel, Ozgul Malcok; Selcoki, Yusuf; Atar, Inci Asli; Eryonucu, Beyhan, E-mail: drdemircelik@yahoo.com [Turgut Ozal Univercity, Department of Cardiology, Ankara (Turkey); Bozkurt, Alper; Akin, Kayihan [Turgut Ozal Univercity, Department of Radiology, Ankara (Turkey); Yilmaz, Omer Caglar [Ankara Occupational Diseases Hospital, Department of Cardiology, Ankara (Turkey)

    2014-06-15

    Objective: the aim of the present study was to investigate the relationship between pericoronary fat and the severity and extent of atherosclerosis, quantified using 64-multidetector computed tomography, in patients with suspected coronary artery disease. Methods: the study population consisted of 131 patients who were clinically referred for noninvasive multislice computed tomography coronary angiography for the evaluation of coronary artery disease. Patients were classified as follows: no atherosclerosis, Group 1; nonobstructive atherosclerosis (luminal narrowing < 50% in diameter), Group 2; and obstructive atherosclerosis (luminal narrowing ≧ 50%) in a single vessel or obstructive atherosclerosis in the left main coronary artery and/or multiple vessels, Group 3. Epicardial adipose tissue was defined as the adipose tissue between the surface of the heart and the visceral layer of the pericardium (visceral epicardium). Epicardial adipose tissue thickness (mm) was determined in the right ventricular anterior free wall. The mean thickness of the pericoronary fat surrounding the three coronary arteries was used for the analyses. Results: the average thickness over all three regions was 13.2 ± 2.1 mm. The pericoronary fat thickness was significantly increased in Group 3 compared with Groups 2 and 1. The epicardial adipose tissue thickness was significantly increased in Group 3 compared with Groups 2 and 1. A receiver operating characteristic curve for obstructive coronary artery disease was assessed to verify the optimum cut-off point for pericoronary fat thickness, which was 13.8 mm. A receiver operating characteristic curve for obstructive coronary artery disease was also assessed to verify the optimum cut-off point for epicardial adipose tissue, which was 6.8 cm. Conclusion: we showed that the epicardial adipose tissue and pericoronary fat thickness scores were higher in patients with obstructive coronary artery diseases. (author)

  6. Value of 64-row spiral CT three-dimensional reconstruction in the repair of tibial plateau fractures%64排螺旋CT三维重建在胫骨平台骨折修复中的价值

    丁燕萍; 杨莹

    2015-01-01

    背景:胫骨平台骨折会抑制膝关节正常功能,严重损伤患者下肢功能,而早期诊断措施对预后效果具有关键作用。以往研究虽已存在多层螺旋 CT 三维重建技术对胫骨平台骨折诊断的相关报道,但将其诊断效果与 X射线检查方式对比较为鲜见。  目的:分析64排螺旋CT三维重建在胫骨平台骨折修复诊治中的应用效果,并与传统X射线诊治结果进行对比。  方法:选择无锡市第九人民医院2012年10月至2013年10月收治的30例胫骨平台骨折患者,对患者进行64排螺旋CT扫描三维重建以及X射线片检查,对检查结果进行分析对比。CT扫描应用GE64排螺旋CT机,扫描范围为胫骨近端,三维重建间距为1 mm,完成扫描后上传工作平台完成图像重建。  结果与结论:通过64排螺旋CT三维重建检查,胫骨平台骨折的程度、有无塌陷、碎骨片存在及移位等均可清晰显示,按照HOHI分型:8例Ⅰ型,7例Ⅱ型,4例Ⅲ型,5例Ⅳ型,3例Ⅴ型,3例Ⅵ型,确诊率为100%;X射线诊断结果显示有25例确诊,有3例为疑似诊断,2例不能确诊,确诊率为83%,两种方式确诊率比较差异有显著性意义(P OBJECTIVE:To analyze the application effect of 64-row spiral CT three-dimensional reconstruction in the repair, diagnosis and treatment of tibial plateau fractures, and compare with diagnostic outcomes of traditional X-ray. METHODS:A total of 30 patients with tibial plateau fractures were selected from Ninth People’s Hospital of Wuxi City from October 2012 to October 2013. Patients were subjected to 64-row spiral CT scanning, three-dimensional reconstruction and X-ray plain film inspection. The inspection results were analyzed and compared. CT scanning used GE64 row spiral CT. Scanning range was the proximal tibia. Spacing of reconstruction was 1 mm. After completing the scan, data were uploaded to a working platform, and

  7. 64排CT气道成像技术在气道异物检查中的临床应用%Clinical application of 64 rows CT airway imaging in the diagnosis of tracheal bronchus foreign body

    赵庆; 齐晨晖; 金艳

    2014-01-01

    目的:评价64排CT气道成像技术对气管支气管异物检查的诊断价值。方法对50例临床怀疑气道异物的患者应用GE Light Speed 64排容积CT(VCT)进行容积扫描,将所得的容积数据经0.625 mm重建后传至工作站,运用CT仿真内窥镜(CTVE)、多平面重组技术(MPR)、容积再现技术+透明化处理(VR+Raysum)、最小密度投影(MinP)对图像进行后处理重建,以支气管镜检查为金标准,评估64排CT检查的敏感性和特异性,并采用χ2检验比较不同后处理方法与支气管镜诊断气管异物形态符合率。结果64排CT扫描结合气道成像技术诊断气道异物的敏感性为100%,特异性为60%,准确率为96%;不同后处理方法(CTVE、MPR、VR+Ray-sum、MinP 4种方法结合)诊断异物形态与支气管镜检查的符合率分别为:98%、87%、82%、42%、100%,不同后处理方法与支气管镜诊断气管异物形态符合率之间差异有统计学意义(χ2=4.810,P<0.05)。结论64排CT气道成像结合不同后处理方法能够提高气道异物诊断的准确性,不同后处理方法联合应用诊断异物形态对指导内窥镜检查或手术有重要意义。%Objective To evaluate the value of 64 rows CT airway imaging in the diagnosis of tracheal bronchus foreign body. Methods Fifty patients with suspected airway foreign body underwent GE Light Speed 64 rows VCT volume scan. The volume data after 0.625 mm reconstruction was send to the workstation, and was recon-structed with CTVE, MPR,VR+ Raysum, MinP. Then taking bronchoscopy as a gold standard, we assessed the sensi-tivity and specificity of 64 rows CT. And we compared the coincidence rate between various post-processing method of airway foreign body and bronchoscopy by Chi square test. Results The sensitivity of 64 rows CT airway imaging in the diagnosis of airway foreign body was 100%, the specificity of it was 60%, and the accuracy of it was 96% . The

  8. Quantitative assessment of bone defect healing by multidetector CT in a pig model

    To evaluate multidetector CT volumetry in the assessment of bone defect healing in comparison to histopathological findings in an animal model. In 16 mini-pigs, a circumscribed tibial bone defect was created. Multidetector CT (MDCT) of the tibia was performed on a 64-row scanner 42 days after the operation. The extent of bone healing was estimated quantitatively by MDCT volumetry using a commercially available software programme (syngo Volume, Siemens, Germany).The volume of the entire defect (including all pixels from -100 to 3,000 HU), the nonconsolidated areas (-100 to 500 HU), and areas of osseous consolidation (500 to 3,000 HU) were assessed and the extent of consolidation was calculated. Histomorphometry served as the reference standard. The extent of osseous consolidation in MDCT volumetry ranged from 19 to 92% (mean 65.4 ± 18.5%). There was a significant correlation between histologically visible newly formed bone and the extent of osseous consolidation on MDCT volumetry (r = 0.82, P < 0.0001). A significant negative correlation was detected between osseous consolidation on MDCT and histological areas of persisting defect (r = -0.9, P < 0.0001). MDCT volumetry is a promising tool for noninvasive monitoring of bone healing, showing excellent correlation with histomorphometry. (orig.)

  9. Quantitative assessment of bone defect healing by multidetector CT in a pig model

    Riegger, Carolin; Kroepil, Patric; Lanzman, Rotem S.; Miese, Falk R.; Antoch, Gerald; Scherer, Axel [University Duesseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Duesseldorf (Germany); Jungbluth, Pascal; Hakimi, Mohssen; Wild, Michael [University Duesseldorf, Medical Faculty, Department of Traumatology and Hand Surgery, Duesseldorf (Germany); Hakimi, Ahmad R. [Universtity Duesseldorf, Medical Faculty, Department of Oral Surgery, Duesseldorf (Germany)

    2012-05-15

    To evaluate multidetector CT volumetry in the assessment of bone defect healing in comparison to histopathological findings in an animal model. In 16 mini-pigs, a circumscribed tibial bone defect was created. Multidetector CT (MDCT) of the tibia was performed on a 64-row scanner 42 days after the operation. The extent of bone healing was estimated quantitatively by MDCT volumetry using a commercially available software programme (syngo Volume, Siemens, Germany).The volume of the entire defect (including all pixels from -100 to 3,000 HU), the nonconsolidated areas (-100 to 500 HU), and areas of osseous consolidation (500 to 3,000 HU) were assessed and the extent of consolidation was calculated. Histomorphometry served as the reference standard. The extent of osseous consolidation in MDCT volumetry ranged from 19 to 92% (mean 65.4 {+-} 18.5%). There was a significant correlation between histologically visible newly formed bone and the extent of osseous consolidation on MDCT volumetry (r = 0.82, P < 0.0001). A significant negative correlation was detected between osseous consolidation on MDCT and histological areas of persisting defect (r = -0.9, P < 0.0001). MDCT volumetry is a promising tool for noninvasive monitoring of bone healing, showing excellent correlation with histomorphometry. (orig.)

  10. Study on motion artifacts in coronary arteries with an anthropomorphic moving heart phantom on an ECG-gated multidetector computed tomography unit

    Acquisition time plays a key role in the quality of cardiac multidetector computed tomography (MDCT) and is directly related to the rotation time of the scanner. The purpose of this study is to examine the influence of heart rate and a multisector reconstruction algorithm on the image quality of coronary arteries of an anthropomorphic adjustable moving heart phantom on an ECG-gated MDCT unit. The heart phantom and a coronary artery phantom were used on a MDCT unit with a rotation time of 500 ms. The movement of the heart was determined by analysis of the images taken at different phases. The results indicate that the movement of the coronary arteries on the heart phantom is comparable to that in a clinical setting. The influence of the heart rate on image quality and artifacts was determined by analysis of several heart rates between 40 and 80 bpm where the movement of the heart was synchronized using a retrospective ECG-gated acquisition protocol. The resulting reformatted volume rendering images of the moving heart and the coronary arteries were qualitatively compared as a result of the heart rate. The evaluation was performed on three independent series by two independent radiologists for the image quality of the coronary arteries and the presence of artifacts. The evaluation shows that at heart rates above 50 bpm the influence of motion artifacts in the coronary arteries becomes apparent. In addition the influence of a dedicated multisector reconstruction technique on image quality was determined. The results show that the image quality of the coronary arteries is not only related to the heart rate and that the influence of the multisector reconstruction technique becomes significant above 70 bpm. Therefore, this study proves that from the actual acquisition time per heart cycle one cannot determine an actual acquisition time, but only a mathematical acquisition time. (orig.)

  11. Diffusion-weighted MR-imaging for the detection of pulmonary nodules at 1.5 Tesla: intraindividual comparison with multidetector computed tomography

    To investigate the feasibility of diffusion-weighted imaging (DWI) MRI for detecting pulmonary nodules at 1.5 Tesla in comparison with standard multidetector computed tomography (MDCT). Twenty patients with disseminated cancer disease in which MDCT had assured the presence of at least one pulmonary nodule were examined using a respiratory-gated DWI MR-sequence. Grey scale inverted source images and coronal maximum intensity projection (MIP) images were consensually analysed by two experienced radiologists. Size and location of any nodule detected were assessed. Additionally, the readers evaluated each hemithorax for the presence of at least one nodule and applied a four-point conspicuity scale (1-hemithorax definitely affected; 4-hemithorax definitely not affected). MDCT data served as reference. At MDCT, a total of 71 pulmonary noduIes was found (size 3–5 mm, n = 16; 6–9 mm, n = 22; ≥10 mm, n = 33). For the DWI MR-sequence, a sensitivity of 86.4% was calculated for nodules ranging 6–9 mm and 97% for nodules ≥10 mm. In contrast, only 43.8% of lesions ≤5 mm was detected. The separate analysis of each hemithorax for the presence of at least one pulmonary nodule revealed a specificity rate, PPV and NPV of DWI-MR of 92.3%, 96% and 80%, respectively. The presented study is the first to confirm the diagnostic potential of DWI-MR in the detection of solid lung nodules. This technique allows for the detection of nodules ≥6 mm with reasonably high sensitivity rates (>86%). The observation of false positive findings decreases the accuracy of this approach compared with MDCT.

  12. Assessment of right ventricular function for patients with rheumatic mitral stenosis by 64-slice multi-detector row computed tomography: comparison with magnetic resonance imaging

    ZHANG Xiao-chun; YANG Zhi-gang; GUO Yin-kun; ZHANG Rui-ming; WANG Jian; ZHOU Dai-quan; CHENG Lin; CHEN Lin

    2012-01-01

    Background Right ventricular (RV) dysfunction ensues due to rheumatic mitral stenosis (RMS).The evaluation of RV function is clinically important for the diagnosis,treatment,and follow-up for patients with different degrees of RMS.Thepurpose of this study was to determine whether the 64-slice multi-detector row computed tomography (64-slice MDCT)can assess the RV function in RMS with high accuracy and reproducibility when compared to MR imaging (MRI).Methods Right ventricular end-diastolic and end-systolic volumes (RV-EDV and RV-ESV),stroke volume (RV-SV),ejection fraction (RV-EF),cardiac output (RV-CO),and wall mass (RV-Mass) were measured with dedicated cardiac analysis software on 64-slice MDCT and compared with values measured with MRI in 43 consecutive patients with RMS.Agreement between MRI and 64-MDCT results were compared with Bland and Altman analysis and linear regression analysis.Repeated measurements were performed to determine intraobserver and interobserver variability.Results No significant differences were revealed in calculated RV function parameters between the two methods.RV-EDV,RV-ESV,RV-SV,RV-EF,RV-CO,and RV-Mass by 64-slice MDCT were similar to those by MRI (P>0.05).There were good correlations (r=0.98,0.97,0.96,0.96,0.95 and 0.77,respectively) and close agreement (bias=-0.2 ml,-1.0ml,0.8 ml,0.5%,26.1 ml,and 0.5 g,respectively,P>0.05).The variability in 64-slice MDCT measurements was similar to that in MRI values.Conclusion ECG-gated 64-slice MDCT could assess the RV function in RMS with high accuracy and reproducibility when compared to MRI.

  13. Iterative reconstruction and individualized automatic tube current selection reduce radiation dose while maintaining image quality in 320-multidetector computed tomography coronary angiography

    Aim: To assess the effect of two iterative reconstruction algorithms (AIDR and AIDR3D) and individualized automatic tube current selection on radiation dose and image quality in computed tomography coronary angiography (CTCA). Materials and methods: In a single-centre cohort study, 942 patients underwent electrocardiogram-gated CTCA using a 320-multidetector CT system. Images from group 1 (n = 228) were reconstructed with a filtered back projection algorithm (Quantum Denoising Software, QDS+). Iterative reconstruction was used for group 2 (AIDR, n = 379) and group 3 (AIDR3D, n = 335). Tube current was selected based on body mass index (BMI) for groups 1 and 2, and selected automatically based on scout image attenuation for group 3. Subjective image quality was graded on a four-point scale (1 = excellent, 4 = non-diagnostic). Results: There were no differences in age (p = 0.975), body mass index (p = 0.435), or heart rate (p = 0.746) between the groups. Image quality improved with iterative reconstruction and automatic tube current selection [1.3 (95% confidence intervals (CI): 1.2–1.4), 1.2 (1.1–1.2) and 1.1 (1–1.2) respectively; p < 0.001] and radiation dose decreased [274 (260–290), 242 (230–253) and 168 (156–180) mGy cm, respectively; p < 0.001]. Conclusion: The application of the latest iterative reconstruction algorithm and individualized automatic tube current selection can substantially reduce radiation dose whilst improving image quality in CTCA

  14. Preoperative differentiation between T1a and ≥T1b gallbladder cancer: combined interpretation of high-resolution ultrasound and multidetector-row computed tomography

    To determine the diagnostic value of combined interpretation of high-resolution ultrasound (HRUS) and multidetector-row computed tomography (MDCT) for preoperative differentiation between T1a and ≥T1b gallbladder (GB) cancer. Eighty-seven patients with pathologically confirmed GB cancers (T1a, n = 15; ≥T1b, n = 72), who preoperatively underwent both HRUS and MDCT, were included in this retrospective study. Two reviewers independently determined the T-stages of the GB cancers on HRUS and MDCT using a five-point confidence scale (5, definitely T1a; 1, definitely ≥T1b). For individual modality interpretation, the lesions with scores ≥4 were classified as T1a, and, for combined modality interpretation, the lesions with all scores ≥4 in both modalities were classified as T1a. The McNemar test was used to compare diagnostic performance. The diagnostic accuracy of differentiation between T1a and ≥T1b GB cancer was higher using combined interpretation (90.8 % and 88.5 % for reviewers 1 and 2, respectively) than individual interpretation of HRUS (82.8 % and 83.9 %) or MDCT (74.7 % and 82.8 %) (P < 0.05, reviewer 1). Combined interpretations demonstrated 100 % specificity for both reviewers, which was significantly higher than individual interpretations (P < 0.05, both reviewers). Combined HRUS and MDCT interpretation may improve the diagnostic accuracy and specificity for differentiating between T1a and ≥T1b GB cancers. circle Differentiating between T1a and ≥T1b gallbladder cancer can help surgical planning. (orig.)

  15. Quantification of normative ranges and baseline predictors of aortoventricular interface dimensions using multi-detector computed tomographic imaging in patients without aortic valve disease

    Highlights: • MDCT imaging of the aortoventricular interface is increasingly common. • We present normative ranges for aortoventricular interface dimensions. • Such techniques and ranges should be used to standardise reporting and research. - Abstract: Background: Multidetector computed tomographic (MDCT) assessment of the aortoventricular interface has gained increased importance with the advent of minimally invasive treatment modalities for aortic and mitral valve disease. This has included a standardised technique of identifying a plane through the nadir of each coronary cusp, the basal plane, and taking further measurements in relation to this plane. Despite this there is no published data defining normal ranges for these aortoventricular metrics in a healthy cohort. This study seeks to quantify normative ranges for MDCT derived aortoventricular dimensions and evaluate baseline demographic and anthropomorphic associates of these measurements in a normal cohort. Methods: 250 consecutive patients undergoing MDCT coronary angiography were included. Aortoventricular dimensions at multiple levels of the aortoventricular interface were assessed and normative ranges quantified. Multivariate linear regression was performed to identify baseline predictors of each metric. Results: The mean age was 59 ± 12 years. The basal plane was eccentric (EI = 0.22 ± 0.06) while the left ventricular outflow tract was more eccentric (EI = 0.32 ±0.06), with no correlation to gender, age or hypertension. Male gender, height and body mass index were consistent independent predictors of larger aortoventricular dimensions at all anatomical levels, while age was predictive of supra-annular measurements. Conclusions: Male gender, height and BMI are independent predictors of all aortoventricular dimensions while age predicts only supra-annular dimensions. Use of defined metrics such as the basal plane and formation of normative ranges for these metrics allows reference for clinical

  16. Assessment of the Right Ventricular Function and Mass Using Cardiac Multi-Detector Computed Tomography in Patients with Chronic Obstructive Pulmonary Disease

    We wanted to assess the relationship between measurements of the right ventricular (RV) function and mass, with using cardiac multi-detector computed tomography (MDCT) and the severity of chronic obstructive pulmonary disease (COPD) as determined by the pulmonary function test (PFT). Measurements of PFT and cardiac MDCT were obtained in 33 COPD patients. Using the Global Initiative for Chronic Obstructive Lung Disease (GOLD) classification, the patients were divided into three groups according to the severity of the disease: stage I (mild, n = 4), stage II (moderate, n = 15) and stage III (severe, n = 14). The RV function and the wall mass were obtained by cardiac MDCT. The results were compared among the groups using the Student-Newman-Keuls method. Person's correlation was used to evaluate the relationship between the right ventricular ejection fraction (RVEF) and the wall mass results with the PFT results. P-values less than 0.05 were considered statistically significant. The RVEF and mass were 47 ±3% and 41 ±2 g in stage I, 46 ±6% and 46 ±5 g in stage II, and 35 ±5% and 55 ±6 g in stage III, respectively. The RVEF was significantly lower in stage III than in stage I and II (p < 0.01). The RV mass was significantly different among the three stages, according to the disease severity of COPD (p < 0.05). The correlation was excellent between the MDCT results and forced expiratory volume in 1 sec (r = 0.797 for RVEF and r -0.769 for RV mass) and forced expiratory volume in 1 sec to the forced vital capacity (r = 0.745 for RVEF and r = -0.718 for RV mass). Our study shows that the mean RV wall mass as measured by cardiac MDCT correlates well with the COPD disease severity as determined by PFT

  17. Quantification of normative ranges and baseline predictors of aortoventricular interface dimensions using multi-detector computed tomographic imaging in patients without aortic valve disease

    Gooley, Robert P., E-mail: robert.gooley@monashhealth.org [MonashHeart, Monash Health, Melbourne 3168 (Australia); Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia); Cameron, James D., E-mail: james.cameron@monash.edu [MonashHeart, Monash Health, Melbourne 3168 (Australia); Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia); Soon, Jennifer, E-mail: jenn.sa@gmail.com [MonashHeart, Monash Health, Melbourne 3168 (Australia); Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia); Loi, Duncan, E-mail: dloi2@student.monash.edu [Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia); Chitale, Gauri, E-mail: gchi21@student.monash.edu [Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia); Syeda, Rifath, E-mail: rssye1@student.monash.edu [Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia); Meredith, Ian T., E-mail: ian.meredith@myheart.id.au [MonashHeart, Monash Health, Melbourne 3168 (Australia); Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia)

    2015-09-15

    Highlights: • MDCT imaging of the aortoventricular interface is increasingly common. • We present normative ranges for aortoventricular interface dimensions. • Such techniques and ranges should be used to standardise reporting and research. - Abstract: Background: Multidetector computed tomographic (MDCT) assessment of the aortoventricular interface has gained increased importance with the advent of minimally invasive treatment modalities for aortic and mitral valve disease. This has included a standardised technique of identifying a plane through the nadir of each coronary cusp, the basal plane, and taking further measurements in relation to this plane. Despite this there is no published data defining normal ranges for these aortoventricular metrics in a healthy cohort. This study seeks to quantify normative ranges for MDCT derived aortoventricular dimensions and evaluate baseline demographic and anthropomorphic associates of these measurements in a normal cohort. Methods: 250 consecutive patients undergoing MDCT coronary angiography were included. Aortoventricular dimensions at multiple levels of the aortoventricular interface were assessed and normative ranges quantified. Multivariate linear regression was performed to identify baseline predictors of each metric. Results: The mean age was 59 ± 12 years. The basal plane was eccentric (EI = 0.22 ± 0.06) while the left ventricular outflow tract was more eccentric (EI = 0.32 ±0.06), with no correlation to gender, age or hypertension. Male gender, height and body mass index were consistent independent predictors of larger aortoventricular dimensions at all anatomical levels, while age was predictive of supra-annular measurements. Conclusions: Male gender, height and BMI are independent predictors of all aortoventricular dimensions while age predicts only supra-annular dimensions. Use of defined metrics such as the basal plane and formation of normative ranges for these metrics allows reference for clinical

  18. Improved vessel morphology measurements in contrast-enhanced multi-detector computed tomography coronary angiography with non-linear post-processing

    Multi-detector computed tomography (MDCT) permits detection of coronary plaque. However, noise and blurring impair accuracy and precision of plaque measurements. The aim of the study was to evaluate MDCT post-processing based on non-linear image deblurring and edge-preserving noise suppression for measurements of plaque size. Contrast-enhanced MDCT coronary angiography was performed in four subjects (mean age 55 ± 5 years, mean heart rate 54 ± 5 bpm) using a 16-slice scanner (Siemens Sensation 16, collimation 16 x 0.75 mm, gantry rotation 420 ms, tube voltage 120 kV, tube current 550 mAs, 80 mL of contrast). Intravascular ultrasound (IVUS; 40 MHz probe) was performed in one vessel in each patient and served as a reference standard. MDCT vessel cross-sectional images (1 mm thickness) were created perpendicular to centerline and aligned with corresponding IVUS images. MDCT images were processed using a deblurring and edge-preserving noise suppression algorithm. Then, three independent blinded observers segmented lumen and outer vessel boundaries in each modality to obtain vessel cross-sectional area and wall area in the unprocessed MDCT cross-sections, post-processed MDCT cross-sections and corresponding IVUS. The wall area measurement difference for unprocessed and post-processed MDCT images relative to IVUS was 0.4 ± 3.8 mm2 and -0.2 ± 2.2 mm2 (p 2, respectively. In conclusion, MDCT permitted accurate in vivo measurement of wall area and vessel cross-sectional area as compared to IVUS. Post-processing to reduce blurring and noise reduced variability of wall area measurements and reduced measurement bias for both wall area and vessel cross-sectional area

  19. Comparing culprit lesions in ST-segment elevation and non-ST-segment elevation acute coronary syndrome with 64-slice multidetector computed tomography

    Background: Classifying acute coronary syndrome (ACS) as ST elevation ACS (STE-ACS) or non-ST elevation ACS (NSTE-ACS) is critical for clinical prognosis and therapeutic decision-making. Assessing the differences in composition and configuration of culprit lesions between STE-ACS and NSTE-ACS can clarify their pathophysiologic differences. Objective: This study focused on evaluating the ability of 64-slice multidetector computed tomography (MDCT) to investigate these differences in culprit lesions in patients with STE-ACS and NSTE-ACS. Methods: Of 161 ACS cases admitted, 120 who fit study criteria underwent MDCT and conventional coronary angiography. The following MDCT data were analyzed: calcium volume, Agatston calcium scores, plaque area, plaque burden, remodeling index, and plaque density. Results: The MDCT angiography had a good correlation with conventional coronary angiography regarding the stenotic severity of culprit lesions (r = 0.86, p 1.05) was significantly higher in the STE-ACS group (81.5% vs. 63.6%, p = 0.031). The patients with STE-ACS had significantly lower MDCT density of culprit lesions than patients with NSTE-ACS (25.8 ± 13.9 HU vs. 43.5 ± 19.1 HU, p < 0.001). Conclusions: Sixty-four-slice MDCT can accurately evaluate the stenotic severity and composition of culprit lesions in selected patients with either STE-ACS or NSTE-ACS. Culprit lesions in NSTE-ACS patients had significantly lower luminal area stenosis, plaque burden, remodeling index and higher MDCT density, which possibly reflect differences in the composition of vulnerable culprit plaques and thrombi.

  20. Comparison of 64-slice multi-detector computed tomography coronary angiography between asymptomatic, type 2 diabetes mellitus and impaired glucose tolerance patients

    Cardiovascular disease is the most frequent cause of death and disability for diabetic patients, and patients with diabetes are more likely to have silent ischemia. Multi-detector computed tomography (MDCT) allows non-invasive assessment of coronary artery stenosis and plaque properties. In this study, we investigated whether 64-slice MDCT can non-invasively identify significant coronary artery stenosis in asymptomatic, type 2 diabetes mellitus (T2DM) and impaired glucose tolerance (IGT) patients. The study population consisted of 154 consecutive asymptomatic patients [IGT (n=93), T2DM (n=61)]. All patients underwent contrast-enhanced 64-slice MDCT. The number of diseased coronary segments was classified as showing obstructive (≥50% luminal narrowing) disease or not. Significant coronary stenosis was detected in 43 (27.9%) of 154 enrolled patients. Patients with T2DM showed significantly more coronary stenosis than patients with IGT (41% vs. 19.4%; p<0.01). Twenty-three patients [14.9%; IGT (n=9), T2DM (n=14)] underwent percutaneous coronary intervention (PCI) for severe stenosis. Patients with T2DM showed significantly more calcified plaque than IGT (47.5% vs. 29%; p<0.05), but not significantly more soft plaque (19.7% vs. 15.1%; ns), or significantly different remodeling index (1.05±0.18 vs. 1.04±0.21; ns), respectively. 64-Slice MDCT can non-invasively identify significant coronary artery stenosis in asymptomatic, T2DM and IGT patients. (author)

  1. Noninvasive Multidetector Computed Tomography Enterography in Patients with Small-Bowel Crohn's Disease: Is a 40-Second Delay Better than 70 Seconds?

    Vandenbroucke, F.; Mortele, K.J.; Tatli, S.; Pelsser, V.; Erturk, S.M.; Mey, J. de; Silverman, S.G. (Div. of Abdominal Imaging and Intervention, Dept. of Radiology, Brigham and Women' s Hospital, Harvard Medical School, Boston, MA (US))

    2007-11-15

    Background: Multidetector computed tomography (MDCT) enterography combines neutral enteric contrast with intravenously administered contrast material. The optimal intravenous (IV) contrast material protocol has still not been established. Purpose: To determine the optimal delay time to image patients with small-bowel Crohn's disease during MDCT enterography. Material and Methods: After oral administration of 1350 ml of neutral contrast medium, 26 patients with small-bowel Crohn's disease underwent MDCT enterography; scans were obtained 40 s (enteric phase) and 70 s (parenchymal phase) after IV administration of 100 ml of iodinated contrast material. Three radiologists, blinded to clinical and pathological findings, independently and retrospectively evaluated each scan in two separate reading sessions for the presence or absence of CT features of Crohn's disease activity. The interobserver agreement was evaluated, and the efficacy of each phase in detecting active disease in the terminal ileum for each reader was determined. The gold standard was pathology (n = 13), endoscopy (n = 3), and clinical evaluation (n = 10). Results: No statistically significant difference was present between the enteric and the parenchymal phase for each reader in each segment regarding the presence or absence of CT features of Crohn's disease. The interobserver agreement for the presence of five main features of active Crohn's disease in the terminal ileum ranged from poor to excellent. The sensitivity, specificity, negative predictive value, positive predictive value, and accuracy for active Crohn's disease in the terminal ileum ranged from 40 to 90%, 88 to 100%, 70 to 94%, 44 to 100%, and 69 to 96%, respectively. There was no statistical difference between the two phases for each reader. Conclusion: MDCT enterography in patients with suspected active Crohn's disease can be obtained at either 40 s or 70 s after IV contrast material

  2. Comparison between Carotid Artery Wall Thickness Measured by Multidetector Row Computed Tomography Angiography and Intimae-Media Thickness Measured by Sonography

    Živorad N. Savić

    2011-01-01

    Full Text Available The increased thickness of the carotid wall >1 mm is a significant predictor of coronary and cerebrovascular diseases. The purpose of our study was to assess the agreement between multidetector row computed tomography angiography (MDCTA in measuring carotid artery wall thickness (CAWT and color Doppler ultrasound (CD-US in measuring intimae-media thickness (IMT. Eighty-nine patients (aged 35–81 were prospectively analyzed using a 64-detector MDCTA and a CD-US scanner. Continuous data were described as the mean value ± standard deviation, and were compared using the Mann–Whitney U test. A p value <0.05 was considered significant. Bland–Altman statistics were employed to measure the agreement between MDCTA and CD-US. CAWT ranged from 0.62 to 1.60 mm, with a mean value of 1.09 mm. IMT ranged from 0.60 to 1.55 mm, with a mean value of 1.06 mm. We observed an excellent agreement between CD-US and MDCTA in the evaluation of the common carotid artery thickness, with a bias between methods of 0.029 mm (which is a highly statistically important difference of absolute values [t = 43.289; p < 0.01] obtained by paired T test, and limits of agreement from 0.04 to 0.104. Pearson correlation coefficient was 0.9997 (95% CI 0.9996–0.9998; p < 0.01. We conclude that there is an excellent correlation between CAWT and IMT measurements obtained with the MDCTA and CD-US.

  3. Noninvasive Multidetector Computed Tomography Enterography in Patients with Small-Bowel Crohn's Disease: Is a 40-Second Delay Better than 70 Seconds?

    Background: Multidetector computed tomography (MDCT) enterography combines neutral enteric contrast with intravenously administered contrast material. The optimal intravenous (IV) contrast material protocol has still not been established. Purpose: To determine the optimal delay time to image patients with small-bowel Crohn's disease during MDCT enterography. Material and Methods: After oral administration of 1350 ml of neutral contrast medium, 26 patients with small-bowel Crohn's disease underwent MDCT enterography; scans were obtained 40 s (enteric phase) and 70 s (parenchymal phase) after IV administration of 100 ml of iodinated contrast material. Three radiologists, blinded to clinical and pathological findings, independently and retrospectively evaluated each scan in two separate reading sessions for the presence or absence of CT features of Crohn's disease activity. The interobserver agreement was evaluated, and the efficacy of each phase in detecting active disease in the terminal ileum for each reader was determined. The gold standard was pathology (n = 13), endoscopy (n = 3), and clinical evaluation (n 10). Results: No statistically significant difference was present between the enteric and the parenchymal phase for each reader in each segment regarding the presence or absence of CT features of Crohn's disease. The interobserver agreement for the presence of five main features of active Crohn's disease in the terminal ileum ranged from poor to excellent. The sensitivity, specificity, negative predictive value, positive predictive value, and accuracy for active Crohn's disease in the terminal ileum ranged from 40 to 90%, 88 to 100%, 70 to 94%, 44 to 100%, and 69 to 96%, respectively. There was no statistical difference between the two phases for each reader. Conclusion: MDCT enterography in patients with suspected active Crohn's disease can be obtained at either 40 s or 70 s after IV contrast material

  4. Data acquisition for experiments with multi-detector arrays

    A Chatterjee; Sushil Kamerkar; A K Jethra; S Padmini; M P Diwakar; S S Pande; M D Ghodgaonkar

    2001-07-01

    Experiments with multi-detector arrays have special requirements and place higher demands on computer data acquisition systems. In this contribution we discuss data acquisition systems with special emphasis on multi-detector arrays and in particular we describe a new data acquisition system, AMPS which we have developed recently which is in regular use in experiments at the Pelletron Laboratory, Mumbai. This includes the in-house development of a dedicated crate controller, PC interface card and software.

  5. Estimation of aortic time-enhancement curve in pharmacokinetic analysis. Dynamic study by multi-detector row computed tomography

    This paper presents an introduction to the development of software that provides a physiologic model of contrast medium enhancement by incorporating available physiologic data and contrast medium pharmacokinetics to predict an organ-specific aortic time-enhancement curve (TEC) in computed tomography (CT) with various contrast medium injection protocols in patients of various heights, weights, cardiac output levels, and so on. The physiologic model of contrast medium enhancement was composed of six compartments for early contrast enhancement pharmacokinetics. Contrast medium is injected via the antecubital vein and distributed to the right side of the heart, the pulmonary compartment, the left side of the heart, and the aorta. It then circulates back to the right side of the heart via the systemic circulation. A computer-based, compartmental model of the aortic system was generated using human physiologic parameters and six differential equations to describe the transport of contrast medium. Aortic TEC generated by the computer-based physiologic model of contrast medium enhancement showed validity and agreement with clinical data and findings published previously. A computer-based physiologic model that may help predict organ-specific CT contrast medium enhancement for different injection protocols was developed. Such a physiologic model may have multiple clinical applications. (author)

  6. Imaging pitfalls, normal anatomy, and anatomical variants that can simulate disease on cardiac imaging as demonstrated on multidetector computed tomography

    Advances in computed tomography have led to continuous improvement in cardiac imaging. Dedicated postprocessing capabilities, faster scan times, and cardiac gating methods reveal details of normal cardiac anatomy and anatomic variants that can mimic pathologic conditions. This article will review normal cardiac anatomy and variants that can mimic disease. Radiologists should be familiar with normal cardiac anatomy and anatomic variants to avoid misinterpretation of normal findings for pathologic processes

  7. The Relationship between Organ Dose and Patients Size in Multidetector Computed Tomography (MDCT) Scans Utilizing Tube Current Modulation (TCM)

    Khatonabadi, Maryam

    2013-01-01

    Computed Tomography (CT) has been one of the leading imaging modalities in today's practice of Radiology. Since its introduction in 1970s, its unique tomographic capability has not only prevented countless number of unnecessary surgeries but also saved lives by early detection of disease. Radiation dose from CT has been estimated to contribute to almost 50% of all medical radiation exposures. Concerns about radiation-induced carcinogenesis have resulted in efforts that encourage monitoring an...

  8. Comparison of gated blood pool SPECT and spiral multidetector computed tomography in the assessment of right ventricular functional parameters. Validation with first-pass radionuclide angiography

    The aim of this study was to compare gated blood pool single photon emission computed tomography (SPECT) (GBPS) and multidetector row computed tomography (MDCT) for the determination of right ventricular ejection fraction (RVEF) and right ventricular volumes (RVV) and to compare first-pass radionuclide angiography (FP-RNA) as the gold standard. Twenty consecutive patients (11 men, 9 women) referred for MDCT for the evaluation of the presence of coronary artery disease underwent FP-RNA and GBPS. The mean right ventricular end-diastolic volume (EDV) calculated with GBPS revealed a statistically significant lower value than that of MDCT. The mean right ventricular end-systolic volume (ESV) calculated with GBPS was also lower than that of MDCT. A comparison of right ventricular EDV from GBPS and MDCT yielded a correlation coefficient of 0.5972. Right ventricular ESV between GBPS and MDCT showed a correlation coefficient of 0.5650. The mean RVEFs calculated with FP-RNA (39.8%±4.0%), GBPS (43.7%±6.9%), and MDCT (40.4%±7.7%) showed no statistical differences (Kruskal-Wallis statistics 4.538, P=0.1034). A comparison of RVEFs from FP-RNA and GBPS yielded a correlation coefficient of 0.7251; RVEFs between FP-RNA and MDCT showed a correlation coefficient of 0.6166 and between GBPS and MDCT showed a correlation coefficient of 0.6367. The RVEF, EDV, and ESV calculated by GBPS had good correlation with those obtained with MDCT. In addition, there were no statistical differences of RVEF calculated from FP-RNA, GBPS, and MDCT. However, with regard to RVV, EDV and ESV from GBPS revealed statistically significantly lower values than those of MDCT. Although reasonable correlations among these modalities were obtained, the agreement among these three modalities was not good enough for interchangeable use in the clinical setting. Also, these results should be confirmed in patients with cardiac diseases in future larger population-based studies. (author)

  9. Cuatro años de experiencia en el uso de tomografía computada multidetector en el trasplante de páncreas: aprendiendo junto a los cirujanos Four years of experience in the use of multidetector computer tomography in pancreas transplantation: a lesson learned together with surgeons

    Hugo José Paladini

    2013-03-01

    .Purpose. To gain knowledge of normal postoperative findings on Multidetector Computed Tomography (MDCT in patients with pancreas transplant and describe the most frequent complications. Topic review. Pancreatic transplantation is currently the only definitive treatment for diabetic patients. In recent years, its use has increased as therapeutic strategy. According to the INCUCAI, in 2001 9 transplants were performed, increasing to 74 in 2011. This increase creates a need for radiologists to gain knowledge of the normal postoperative anatomy and learn to identify the most frequent postoperative complications. The imaging methods used are Doppler / ultrasound, MDCT, conventional angiography and MRI. In patients with good renal function in whom ultrasound is not diagnostic for characterization of complications, the next step is MDCT. At our hospital, 25 pancreatic transplants were performed in 2008-2012. Postoperative complications were suspected clinically or by ultrasound in 19 of them. Fifteen of them were evaluated by CT for further characterization Imaging findings or procedure details. As we learn the surgical techniques that were performed, normal images are described, allowing a correct interpretation of MDCT findings in these patients. The most common post operative complications were: - Vascular: thrombosis, arteriovenous fistula, pseudoaneurysm - Non vascular: pancreatitis, pancreatic fistulas, collections, pneumoperitoneum, ileus. Conclusion: MDCT is a useful method for assessing patients with pancreas transplantation. A clear understanding of the unique anatomy and possible postoperative complications is crucial for the radiologist to guide the monitoring and treatment of this patient.

  10. Multidetector computed tomography (MDCT) evaluation of myocardial viability: intraindividual comparison of monomeric vs. dimeric contrast media in a rabbit model

    Mahnken, Andreas H. [RWTH Aachen University, Department of Diagnostic Radiology, Aachen (Germany)]|[RWTH Aachen University, Applied Medical Engineering, Helmholtz Institute, Aachen (Germany)]|[University Hospital, RWTH Aachen University, Department of Diagnostic Radiology, Aachen (Germany); Jost, Gregor; Sieber, Martin; Seidensticker, Peter R.; Pietsch, Hubertus [Bayer-Schering Pharma AG, Berlin (Germany); Bruners, Philipp [RWTH Aachen University, Department of Diagnostic Radiology, Aachen (Germany)]|[RWTH Aachen University, Applied Medical Engineering, Helmholtz Institute, Aachen (Germany); Guenther, Rolf W. [RWTH Aachen University, Department of Diagnostic Radiology, Aachen (Germany)

    2009-02-15

    To evaluate the influence of different types of iodinated contrast media on the assessment of myocardial viability, acute myocardial infarction (MI) was surgically induced in six rabbits. Over a period of 45 min, contrast-enhanced cardiac MDCT (64 x 0.6 mm, 80 kV, 680mAs{sub eff.}) was repeatedly performed using a contrast medium dose of 600 mg iodine/kg body weight. Animals received randomized iopromide 300 and iodixanol 320, respectively. Attenuation values of healthy and infarcted myocardium were measured. The size of MI was computed and compared with nitroblue tetrazolium (NBT)-stained specimen. The highest attenuation differences between infarcted and healthy myocardium occurred during the arterial phase with 140.0{+-}3.5 HU and 141.0{+-}2.2 HU for iopromide and iodixanol, respectively. For iodixanol the highest attenuation difference on delayed contrast-enhanced images was achieved 3 min post injection (73.5 HU). A slightly higher attenuation difference was observed for iopromide 6 min after contrast medium injection (82.2 HU), although not statistically significant (p=0.6437). Mean infarct volume as measured by NBT staining was 33.5%{+-}13.6%. There was an excellent agreement of infarct sizes among NBT-, iopromide- and iodixanol-enhanced MDCT with concordance-correlation coefficients ranging from {rho}{sub (c)=} 0.9928-0.9982. Iopromide and iodixanol both allow a reliable assessment of MI with delayed contrast-enhanced MDCT. (orig.)

  11. Comparison of 16 slice multi-detector computed tomography and breath hold 3D magnetic resonance angiography in the detection of coronary stenosis

    Xin LIU; Zulong CAI; Youquan CAI; Shaohong ZHAO; Ningyu AN; Yuangui GAO

    2006-01-01

    Objective To compare 16-slice multi-detector spiral computed tomography (MDCT) and breathhold 3D magnetic resonance (MR) coronary angiography in the visualization of coronary arteries and the accuracy of detecting significant (> 50%) coronary stenoses in patients with suspected coronary artery disease. Methods Forty patients were examined by 16-slice CT (GE, Lightspeedl6)and MR (GE,Twinspeed) within 3 days; 31 of them underwent conventional coronary angiography (CAG) within 2 weeks after CT and MR scan. CT was performed with 16× 1.25 mm detector collimation, 0.5 s rotation time and images were reconstructed at 60%-75% of the cardiac cycle. MR was performed with breath hold 3D FIESTA (TR4.0 ms, TE1.7 ms, flip angle 65, slice thickness 3 mm, FOV 280 mm, matrix 256× 192). Mean heart rate was 63 ± 5.8 bpm and β-blocker was used in 24 patients. MR and CT image quality was evaluated in 9 coronary segments (RCA1, RCA2, RCA3, LM, LAD1, LAD2, LAD3, LCX1, LCX2) using a four-point grading scale.Sensitivity, specificity, positive predictive value, negative predictive value and accuracy were calculated for detection of significant stenosis using CAG as the gold standard. Results 16-slice CT showed higher image quality in most coronary segments except RCA2.Forty-three segments were diagnosed as significant stenosis by CAG, 36 and 27 of these were correctly detected by CT and MR respectively. Sensitivity, specificity, positive predictive value, and negative predictive value of 16-slice CT and MR for detecting significant stenosis were 83 %, 84 %, 49 %, 97 % and 63 %, 90 %, 55 %, 93 %, respectively. Conclusion Sixteen-slice CT showed higher image quality in most coronary segments excepted for middle RCA. 16-slice CT had higher sensitivity than MR for detection of coronary significant stenosis, whereas MR had higher specificity than CT. Both CT and MR showed high negative predictive value,which is useful for excluding coronary stenosis in symptomatic patients.

  12. Detection of non-ST-elevation myocardial infarction and unstable angina in the acute setting: meta-analysis of diagnostic performance of multi-detector computed tomographic angiography

    Sarno Giovanna

    2007-12-01

    Full Text Available Abstract Background Multi-detector computed tomography angiography (MDCTA has been increasingly used in the evaluation of the coronary arteries. The purpose of this study was to review the literature on the diagnostic performance of MDCTA in the acute setting, for the detection of non-ST-elevation myocardial infarction (NSTEMI and unstable angina pectoris (UAP. Methods A Pubmed and manual search of the literature published between January 2000 and June 2007 was performed. Studies were included that compared MDCTA with clinical outcome and/or CA in patients with acute chest pain, presenting at the emergency department. More specifically, studies that only included patients with initially negative cardiac enzymes suspected of having NSTEMI or UAP were included. Summary estimates of diagnostic odds ratio (DOR, sensitivity and specificity, negative (NLR and positive likelihood ratio (PLR were calculated on a patient basis. Random-effects models and summary receiver operating curve (SROC analysis were used to assess the diagnostic performance of MDCTA with 4 detectors or more. The proportion of non assessable scans (NAP on MDCTA was also evaluated. In addition, the influence of study characteristics of each study on diagnostic performance and NAP was investigated with multivariable logistic regression. Results Nine studies totalling 566 patients, were included in the meta-analysis: one randomised trial and eight prospective cohort studies. Five studies on 64-detector MDCTA and 4 studies on MDCTA with less than 64 detectors were included (32 detectors n = 1, 16 detectors n = 2, 16 and 4 detectors n = 1. Pooled DOR was 131.81 (95%CI, 50.90–341.31. The pooled sensitivity and specificity were 0.95 (95%CI, 0.90–0.98 and 0.90 (95%CI, 0.87–0.93. The pooled NLR and PLR were 0.12 (95%CI, 0.06–0.21 and 8,60 (95%CI, 5.03–14,69. The results of the logistic regressions showed that none of the investigated variables had influence on the diagnostic

  13. Improved vessel morphology measurements in contrast-enhanced multi-detector computed tomography coronary angiography with non-linear post-processing

    Ferencik, Maros [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, 165 Cambridge Street, Suite 400, Boston, MA 02114 (United States)]. E-mail: maros_ferencik@hms.harvard.edu; Lisauskas, Jennifer B. [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, 165 Cambridge Street, Suite 400, Boston, MA 02114 (United States); Cury, Ricardo C. [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, 165 Cambridge Street, Suite 400, Boston, MA 02114 (United States); Hoffmann, Udo [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, 165 Cambridge Street, Suite 400, Boston, MA 02114 (United States); Abbara, Suhny [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, 165 Cambridge Street, Suite 400, Boston, MA 02114 (United States); Achenbach, Stephan [Department of Medicine II, University of Erlangen, Ulmenweg 18, Erlangen (Germany); Karl, W. Clem [Department of Electrical and Computer Engineering, 8 Saint Mary' s Street, Boston University, Boston, MA (United States); Brady, Thomas J. [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, 165 Cambridge Street, Suite 400, Boston, MA 02114 (United States); Chan, Raymond C. [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, 165 Cambridge Street, Suite 400, Boston, MA 02114 (United States)

    2006-03-15

    Multi-detector computed tomography (MDCT) permits detection of coronary plaque. However, noise and blurring impair accuracy and precision of plaque measurements. The aim of the study was to evaluate MDCT post-processing based on non-linear image deblurring and edge-preserving noise suppression for measurements of plaque size. Contrast-enhanced MDCT coronary angiography was performed in four subjects (mean age 55 {+-} 5 years, mean heart rate 54 {+-} 5 bpm) using a 16-slice scanner (Siemens Sensation 16, collimation 16 x 0.75 mm, gantry rotation 420 ms, tube voltage 120 kV, tube current 550 mAs, 80 mL of contrast). Intravascular ultrasound (IVUS; 40 MHz probe) was performed in one vessel in each patient and served as a reference standard. MDCT vessel cross-sectional images (1 mm thickness) were created perpendicular to centerline and aligned with corresponding IVUS images. MDCT images were processed using a deblurring and edge-preserving noise suppression algorithm. Then, three independent blinded observers segmented lumen and outer vessel boundaries in each modality to obtain vessel cross-sectional area and wall area in the unprocessed MDCT cross-sections, post-processed MDCT cross-sections and corresponding IVUS. The wall area measurement difference for unprocessed and post-processed MDCT images relative to IVUS was 0.4 {+-} 3.8 mm{sup 2} and -0.2 {+-} 2.2 mm{sup 2} (p < 0.05), respectively. Similarly, Bland-Altman analysis of vessel cross-sectional area from unprocessed and post-processed MDCT images relative to IVUS showed a measurement difference of 1.0 {+-} 4.4 and 0.6 {+-} 4.8 mm{sup 2}, respectively. In conclusion, MDCT permitted accurate in vivo measurement of wall area and vessel cross-sectional area as compared to IVUS. Post-processing to reduce blurring and noise reduced variability of wall area measurements and reduced measurement bias for both wall area and vessel cross-sectional area.

  14. Coronary artery bypass graft (CABG) patency: Assessment with high-resolution submillimeter 16-slice multidetector-row computed tomography (MDCT) versus coronary angiography

    Anders, Katharina [Department of Radiology, Friedrich-Alexander University of Erlangen-Nuremberg (Germany)]. E-mail: katharina.anders@idr.imed.uni-erlangen.de; Baum, Ulrich [Department of Radiology, Friedrich-Alexander University of Erlangen-Nuremberg (Germany); Schmid, Michael [Department of Internal Medicine II, Friedrich-Alexander University of Erlangen-Nuremberg (Germany); Ropers, Dieter [Department of Internal Medicine II, Friedrich-Alexander University of Erlangen-Nuremberg (Germany); Schmid, Axel [Department of Radiology, Friedrich-Alexander University of Erlangen-Nuremberg (Germany); Pohle, Karsten [Department of Internal Medicine II, Friedrich-Alexander University of Erlangen-Nuremberg (Germany); Daniel, Werner G. [Department of Internal Medicine II, Friedrich-Alexander University of Erlangen-Nuremberg (Germany); Bautz, Werner [Department of Radiology, Friedrich-Alexander University of Erlangen-Nuremberg (Germany); Achenbach, Stephan [Department of Internal Medicine II, Friedrich-Alexander University of Erlangen-Nuremberg (Germany)

    2006-03-15

    Purpose: To investigate the ability of 16-slice multidetector-row computed tomography (MDCT) to visualize coronary artery bypass graft (CABG) patency and to detect bypass stenoses. Materials and methods: Thirty-two patients with 94 grafts (20 mammary artery grafts, 74 venous grafts) were investigated by 16-slice MDCT using a scan protocol with 12 x 0.75 mm slice collimation (pitch 0.3), 420 ms rotation time and simultaneous electrocardiogram (ECG)-registration. One hundred milliliters iodinated contrast agent were injected with a delay according to the individually determined contrast agent transit time. Patients with heart rates above 60 bpm received oral beta-blockade. Cross-sectional images with a slice width of 1.0 mm (0.5 mm increment) were reconstructed using an ECG-gated half-scan reconstruction or a multisegment reconstruction algorithm depending on the heart rate. Bypass grafts were evaluated concerning patency and presence of stenoses {>=}50% diameter reduction on cross-sectional images, multiplanar reformations and maximum intensity projections by two independent observers. Results were compared to coronary bypass angiography. Results: Sixteen-slice MDCT results were compared to those of invasive coronary angiography concerning absence or presence of bypass graft occlusion or relevant stenosis {>=}50% lumen reduction. Coronary CT angiography (CTA) permitted detection of bypass occlusion with 100% sensitivity (28/28) and 98% specificity (64/65). Seventy-eight percent (observer 1) and 84% (observer 2) of all patent grafts were found to be evaluable concerning presence or absence of stenosis. In 34 of 40 (observer 1) and 38 of 43 (observer 2) bypass grafts, high-grade stenoses were correctly ruled out (specificity 85% versus 88%, sensitivity 80% and 82%). Yet, if all patients with either unevaluable grafts/graft anastomosis or relevant graft stenosis were excluded, only 8/32 patients (25%) had fully diagnostic 'negative' graft-CTA. According to

  15. Comparing culprit lesions in ST-segment elevation and non-ST-segment elevation acute coronary syndrome with 64-slice multidetector computed tomography

    Huang, W.-C. [School of Medicine, National Yang-Ming University, Taipei, Taiwan (China); Cardiovascular Medical Center, Kaohsiung Veterans General Hospital, No. 386, Dar-Chung First Road, Kaohsiung, Taiwan (China)], E-mail: w.c.huang@yahoo.com.tw; Liu, C.-P. [School of Medicine, National Yang-Ming University, Taipei, Taiwan (China); Cardiovascular Medical Center, Kaohsiung Veterans General Hospital, No. 386, Dar-Chung First Road, Kaohsiung, Taiwan (China)], E-mail: cpliu@isca.vghks.gov.tw; Wu, M.-T. [School of Medicine, National Yang-Ming University, Taipei, Taiwan (China); Department of Radiology, Kaohsiung Veterans General Hospital, No. 386, Dar-Chung First Road, Kaohsiung, Taiwan (China)], E-mail: wu.mingting@gmail.com; Mar, G.-Y. [Cardiovascular Medical Center, Kaohsiung Veterans General Hospital, No. 386, Dar-Chung First Road, Kaohsiung, Taiwan (China)], E-mail: gymar@isca.vghks.gov.tw; Lin, S.-K. [Cardiovascular Medical Center, Kaohsiung Veterans General Hospital, No. 386, Dar-Chung First Road, Kaohsiung, Taiwan (China)], E-mail: skyii89@yahoo.com.tw; Hsiao, S.-H. [Cardiovascular Medical Center, Kaohsiung Veterans General Hospital, No. 386, Dar-Chung First Road, Kaohsiung, Taiwan (China)], E-mail: a841120@ms3.hinet.net; Lin, S.-L. [School of Medicine, National Yang-Ming University, Taipei, Taiwan (China); Cardiovascular Medical Center, Kaohsiung Veterans General Hospital, No. 386, Dar-Chung First Road, Kaohsiung, Taiwan (China)], E-mail: sllin@isca.vghks.gov.tw; Chiou, K.-R. [School of Medicine, National Yang-Ming University, Taipei, Taiwan (China); Cardiovascular Medical Center, Kaohsiung Veterans General Hospital, No. 386, Dar-Chung First Road, Kaohsiung, Taiwan (China)], E-mail: krchiou@isca.vghks.gov.tw

    2010-01-15

    Background: Classifying acute coronary syndrome (ACS) as ST elevation ACS (STE-ACS) or non-ST elevation ACS (NSTE-ACS) is critical for clinical prognosis and therapeutic decision-making. Assessing the differences in composition and configuration of culprit lesions between STE-ACS and NSTE-ACS can clarify their pathophysiologic differences. Objective: This study focused on evaluating the ability of 64-slice multidetector computed tomography (MDCT) to investigate these differences in culprit lesions in patients with STE-ACS and NSTE-ACS. Methods: Of 161 ACS cases admitted, 120 who fit study criteria underwent MDCT and conventional coronary angiography. The following MDCT data were analyzed: calcium volume, Agatston calcium scores, plaque area, plaque burden, remodeling index, and plaque density. Results: The MDCT angiography had a good correlation with conventional coronary angiography regarding the stenotic severity of culprit lesions (r = 0.86, p < 0.001). The STE-ACS culprit lesions (n = 54) had significantly higher luminal area stenosis (78.6 {+-} 21.2% vs. 66.7 {+-} 23.9%, p = 0.006), larger plaque burden (0.91 {+-} 0.10 vs. 0.84 {+-} 0.12, p = 0.007) and remodeling index (1.28 {+-} 0.34 vs. 1.16 {+-} 0.22, p = 0.021) than those with NSTE-ACS (n = 66). The percentage of expanding remodeling index (remodeling index >1.05) was significantly higher in the STE-ACS group (81.5% vs. 63.6%, p = 0.031). The patients with STE-ACS had significantly lower MDCT density of culprit lesions than patients with NSTE-ACS (25.8 {+-} 13.9 HU vs. 43.5 {+-} 19.1 HU, p < 0.001). Conclusions: Sixty-four-slice MDCT can accurately evaluate the stenotic severity and composition of culprit lesions in selected patients with either STE-ACS or NSTE-ACS. Culprit lesions in NSTE-ACS patients had significantly lower luminal area stenosis, plaque burden, remodeling index and higher MDCT density, which possibly reflect differences in the composition of vulnerable culprit plaques and thrombi.

  16. Reconstruction of coronary 64-multidetector-row computed tomography angiography in patients with atrial fibrillation. Delete short RR intervals using electorocardiogram

    The image qualities of coronary 64-multidetector-row computed tomography angiography (CCTA) in patients with atrial fibrillation (Afib) are often not enough. This study clarifies how to use electrocardiogram (ECG)-editing in Afib. We performed CCTA (Aquilion 64 with beam pitch: 0.125, 0.35 s/r) in 33 patients (M/F=24/9, age: 71±9 yr, mean heart rate: 71±12 bpm) with Afib. We injected 5 mg of verapamil into the vein when the mean heart rate (HR) was ≥80 bpm. First, we reconstructed images after deleting short risk ratio (RR) (<800, 750, 700, 650, or 600). Second, we reconstructed images in 4 different methods: (1) end-systolic images with Phase Navi (automatically selecting an optimal phase) (ES-Navi), (2) Mid-diastolic images with Phase Navi (MD-Navi), (3) Mid-diastolic images reconstructed by the ''R + absolute time method'' [Edit-MD (R+)], and (4) Mid-diastolic images reconstructed by the ''R-absolute time method'' [Edit-MD (R-)]. We reconstructed 1 and 2 without ECG-editing, and 3 and 4 were reconstructed after ECG-editing without a data deficit. The quality of the images was classified into 3 ranks: no artifact (3), mild artifact (2), and severe artifact (1). The image quality point of CCTA, reconstructed after deleting RR <750, was similar to RR <800, and RR <750 was even higher than that after deleting HR <600, 650, or 700. The mean image quality point of CCTA that was reconstructed by Edit-MD (R-) or Edit-MD (R+) was significantly higher than ES-Navi or MD-Navi. The high image quality of CCTA could be reconstructed after deleting RR <750 in 76% or after deleting RR <800 in 70% of Afib. The reconstruction using Edit-MD (R-) or Edit-MD (R+) without a data deficit could provide a better quality CCTA than using PhaseNavi in Afib. (author)

  17. Multidetector-Row Computed Tomographic Angiography Findings of Musculoskeletal Tumors: Retrospective Analysis and Correlation with Surgical Findings

    Background: Although magnetic resonance imaging (MRI) is a valuable method in staging musculoskeletal tumors, it may not give enough information on the association between the tumor and the main vascular structures adjacent to the tumor. In this respect, computed tomographic angiography (CTA) may be a useful alternative imaging technique. Purpose: To evaluate the effectiveness of CTA in determining vascular invasion in patients with musculoskeletal tumors and suspected vascular invasion by MRI, and to correlate the CTA findings with the surgical findings. Material and Methods: Twenty patients who had musculoskeletal tumors and lacked a fat plane between the tumor and adjacent vessels by MRI were included in this study. All patients were evaluated with CTA, and the CTA findings were reviewed by two radiologists to determine the presence of vascular invasion. Statistical analysis was carried out by using surgical findings as the gold standard. Results: There were nine women and 11 men (mean age 31 years) with either bone (n=9) or soft-tissue (n=11) tumors. Twelve patients without invasion according to the CTA examination were also surgically negative (true-negative cases). Of the eight patients with invasion shown by CTA, only three had adhesions and were considered surgically negative (false-positive cases). Five had invasions proven by surgery and were considered surgically positive (true-positive cases). Compared to the surgical findings, CTA had 100% sensitivity, 80% specificity, 62.5% positive predictive value, 100% negative predictive value, and 80% accuracy. Conclusion: CTA is a more accurate imaging technique than MRI in evaluating vascular invasion of musculoskeletal tumors, and provides valuable preoperative data

  18. Myocardial Bridging of the Right Coronary Artery inside the Right Atrial Myocardium Identified by ECG-gated 64-slice Multidetector Computed Tomography Angiography

    Yung-Liang Wan; Ming-Shien Wen; Fen-Chiung Lin; Chen-Ju Fu; Huan-Wu Chen; Chien-Cheng Chen; Yuan-Chang Liu

    2010-01-01

    A myocardial bridge (MB) is defined as an intramyocardial course of a major epicardialcoronary artery, and it is mainly confined to the left ventricle and the left anterior descendingcoronary artery. There are rare reports of right coronary MB seen during angiographicexamination. Herein, we present a 49 year-old man with right coronary artery MB withoutluminal narrowing in the diastolic and systolic phases of electrocardiography-gated computedtomography images. The value of multi-detector com...

  19. Patient radiation dose from computed tomography angiography and digital subtraction angiography of the brain

    Netwong, Y.; Krisanachinda, A.

    2016-03-01

    The 64-row multidetector computed tomography angiography (64-MDCTA) provides vascular image quality of the brain similar to digital subtraction angiography (DSA), but the effective dose of CTA is lower than DSA studied in phantom. The purpose of this study is to evaluate the effective dose from 64-MDCTA and DSA. Effective dose (according to ICRP 103) from 64-MDCTA and DSA flat panel detector for cerebral vessels examination of the brain using standard protocols as recommended by the manufacturer was calculated for 30 cases of MDCTA (15 male and 15 female).The mean patient age was 49.5 (23-89) yrs. 30 cases of DSA (14 male and 16 female), the mean patient age was 46.8 (21-81) yrs. For CTA, the mean effective dose was 3.7 (2.82- 5.19) mSv. For DSA, the mean effective dose was 5.78 (3.3-10.06) mSv. The effective dose of CTA depends on the scanning protocol and scan length. Low tube current can reduce patient dose whereas the number of exposures and number of series in 3D rotational angiography (3D RA) resulted in increasing effective dose in DSA patients.

  20. Multi-detector computed tomography radiation doses in the follow-up of paediatric neurosurgery patients in KwaZulu-Natal: A dosimetric audit

    Christopher T. Sikwila

    2014-05-01

    Full Text Available Background: Multi-detector computed tomography (MDCT is the preferred modality for follow-up of paediatric neurosurgery patients. Serial imaging, however, has the disadvantage of an ionising radiation burden, which may be mitigated using the ‘as low as reasonably achievable’ (ALARA principle. Objectives: The primary objectives were to determine the radiation dose exposure in paediatric patients subjected to MDCT imaging following neurosurgery and to compare these values with references in current literature. Our secondary objective was to assess the relationship between radiation dose and clinical scenario. Method: Retrospective descriptive data were collected from all paediatric postsurgical patients (n = 169 between the ages of 0 and 12 years who had their first followed-up scan in the year 2010 and were followed up for six months or less. Dose-length product (DLP and current-time product were collected from the picture archiving and communication system. Demographic data including radiology reports were collected from the hospital information system. The effective doses (ED were calculated from the corresponding DLP using age-adjusted conversion factors. For purposes of comparison with other studies, median dosimetric values were calculated and the children were grouped into three age ranges, namely younger than 3 years, 3–7 years and 8–12 years old. Results: The highest median radiation doses were noted in patients being followed-up for intracranial abscesses (1183 mGy cm in the 8–12 year age group, most of whom were female. The lowest radiation doses were for intracranial shunt follow-ups (447 mGy cm. Median values for DLP, ED and current-time product (mAs were comparable to reference doses in all three age groups. However, our study showed a much broader distribution of values with higher upper limits relative to reference values. Indications for follow-up included shunts (n = 110; 65%, intracranial abscess (n = 31; 18%, subdural

  1. Comparison of the radiation dose from cone beam computed tomography and multidetector computed tomography in examinations of the hand; Vergleich der Strahlendosis von Cone-Beam Computertomografie und Multidetektor Computertomografie in Untersuchungen der Hand

    Neubauer, J.; Neubauer, C.; Gerstmair, A.; Krauss, T.; Kotter, E.; Langer, M. [University Medical Center Freiburg (Germany). Dept. of Radiology; Reising, K. [University Medical Center Freiburg (Germany). Dept. of Orthopedics and Trauma Surgery; Zajonc, H. [University Medical Center Freiburg (Germany). Dept. of Plastic and Hand Surgery; Fiebich, M.; Voigt, J. [University of Applied Sciences, Giessen (Germany). Inst. of Medical Physics and Radiation Protection

    2016-05-15

    Comparison of radiation dose of cone beam computed tomography (CBCT) and multidetector computed tomography (MDCT) in examinations of the hand. Dose calculations were carried out by means of Monte Carlo simulations in MDCT and CBCT. A corpse hand was examined in a 320-row MDCT scanner and a dedicated extremities CBCT scanner with standard protocols and multiple low-dose protocols. The image quality of the examinations was evaluated by 5 investigators using a Likert scale from 1 (very good) to 5 (very poor) regarding depiction of cortical bone, cancellous bone, joint surfaces, soft tissues and artifacts. For a sum of ratings of all structures < 50 a good overall image quality was expected. The studies with at least good overall image quality were compared with respect to the dose. The dose of the standard examination was 13.21 (12.96 to 13.46 CI) mGy in MDCT and 7.15 (6.99 to 7.30 CI) mGy in CBCT. The lowest dose in a study with good overall image quality was 4.54 (4.43 to 4.64 CI) mGy in MDCT and 5.72 (5.59 to 5.85 CI) mGy in CBCT. Although the dose of the standard protocols in the CBCT is lower than in the MDCT, the MDCT can realize a good overall image quality at a lower dose than the CBCT. Dose optimization of CT examination protocols for the hand is useful in both modalities, the MDCT has an even greater potential for optimization.

  2. Multidetector computerized tomography enema versus magnetic resonance enema in the diagnosis of rectosigmoid endometriosis

    Biscaldi, Ennio, E-mail: ennio.biscaldi@gmail.com [Department of Radiology, Galliera Hospital, via Mura delle Capuccine 14, 16128 Genoa (Italy); Ferrero, Simone, E-mail: simone.ferrero@unige.it [Department of Obstetrics and Gynecology, San Martino Hospital and National Institute for Cancer Research, University of Genoa, Largo Rosanna Benzi, 1, 16132 Genoa (Italy); Leone Roberti Maggiore, Umberto, E-mail: ulrm@libero.it [Department of Obstetrics and Gynecology, San Martino Hospital and National Institute for Cancer Research, University of Genoa, Largo Rosanna Benzi, 1, 16132 Genoa (Italy); Remorgida, Valentino, E-mail: vremorgida@yahoo.it [Department of Obstetrics and Gynecology, San Martino Hospital and National Institute for Cancer Research, University of Genoa, Largo Rosanna Benzi, 1, 16132 Genoa (Italy); Venturini, Pier Luigi, E-mail: venturini@unige.it [Department of Obstetrics and Gynecology, San Martino Hospital and National Institute for Cancer Research, University of Genoa, Largo Rosanna Benzi, 1, 16132 Genoa (Italy); Rollandi, Gian Andrea, E-mail: rollandi@galliera.it [Department of Radiology, Galliera Hospital, via Mura delle Capuccine 14, 16128 Genoa (Italy)

    2014-02-15

    Purpose: To compare the accuracy of multidetector computerized tomography enema (MDCT-e) and magnetic resonance enema (MRI-e) in determining the presence of sigmoid and rectal endometriotic nodules. Materials and methods: 260 women (32.6 ± 4.3 years) with symptoms suggestive of rectosigmoid endometriosis underwent MDCT-e and MRI-e prior to laparoscopy. After retrograde colonic distention and injection of intravenous contrast medium, patients were scanned on a 64-row MDCT scanner. MRI-e was performed on a 1.5 T magnet using an 8 channels phased array coil; intestinal distention was achieved by introducing in the rectum 250–300 ml of ultrasonographic gel diluted with saline solution. Radiological findings were compared with surgical and histological results. Results: 176 women had rectosigmoid endometriosis at surgery. There was no significant difference in the accuracy of MDCT-e (98.5%) and MRI-e (96.9%) in the diagnosis of sigmoid and rectal endometriosis (p = 0.248). The sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio and negative likelihood ratio of MDCT-e and MRI-e were respectively 98.3%, 98.8%, 99.4%, 96.5%, 81.59, 0.02 and 97.2%, 96.4%, 98.3%, 94.1%, 26.89, 0.03. Conclusions: Both MDCT-e and MRI-e are accurate in the diagnosis of rectal and sigmoid endometriosis.

  3. Multidetector computerized tomography enema versus magnetic resonance enema in the diagnosis of rectosigmoid endometriosis

    Purpose: To compare the accuracy of multidetector computerized tomography enema (MDCT-e) and magnetic resonance enema (MRI-e) in determining the presence of sigmoid and rectal endometriotic nodules. Materials and methods: 260 women (32.6 ± 4.3 years) with symptoms suggestive of rectosigmoid endometriosis underwent MDCT-e and MRI-e prior to laparoscopy. After retrograde colonic distention and injection of intravenous contrast medium, patients were scanned on a 64-row MDCT scanner. MRI-e was performed on a 1.5 T magnet using an 8 channels phased array coil; intestinal distention was achieved by introducing in the rectum 250–300 ml of ultrasonographic gel diluted with saline solution. Radiological findings were compared with surgical and histological results. Results: 176 women had rectosigmoid endometriosis at surgery. There was no significant difference in the accuracy of MDCT-e (98.5%) and MRI-e (96.9%) in the diagnosis of sigmoid and rectal endometriosis (p = 0.248). The sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio and negative likelihood ratio of MDCT-e and MRI-e were respectively 98.3%, 98.8%, 99.4%, 96.5%, 81.59, 0.02 and 97.2%, 96.4%, 98.3%, 94.1%, 26.89, 0.03. Conclusions: Both MDCT-e and MRI-e are accurate in the diagnosis of rectal and sigmoid endometriosis

  4. Visualization of pulmonary vein stenosis after radio frequency ablation for treatment of atrial fibrillation using multidetector computed tomography with retrospective gating; Darstellung von Pulmonalvenenstenosen nach Radiofrequenzablation zur Behandlung von Vorhofflimmern unter Verwendung der Multidetektor Computertomographie mit retrospektivem Gating

    Trabold, T.; Kuettner, A.; Heuschmid, M.; Kopp, A.F.; Claussen, C.D. [Radiologische Klinik, Abt. fuer Radiologische Diagnostik, Univ. Tuebingen (Germany); Burgstahler, C.; Mewis, C.; Schroeder, S.; Kuehlkamp, V. [Medizinische Klinik III, Abt. fuer Kardiologie, Univ. Tuebingen (Germany)

    2003-01-01

    Purpose: With the number of radio frequency ablations (RFA) for treatment of chronic atrial fibrillation increasing, the diagnostic evaluation for RFA associated pulmonary vein stenosis is getting more important. This study investigates the feasibility of the visualization of pulmonary vein stenosis using non-invasive multidetector computed tomography. Materials and Methods: Twenty-eight patients were examined following RFA-treatment. A 4-slice (20 patients) and a 16-slice (8 patients) multidetector CT scanner (SOMATOM Volume Zoom and Sensation 16, Siemens, Forchheim, Germany) with retrospective gating was used to assess the pulmonary veins. Lesion severity was determined on a semi-quantitative scale (< 30%, 30 - 50%, > 50%). Results: CT was performed without any complications in all patients. Diagnostic image quality could be obtained in all examinations. The pulmonary veins showed lesions < 30% in four patients, lesions of 30 - 50% in five patients and a stenosis > 50% in one patient. Eighteen patients showed no lesions. Conclusion: Multidetector CT of the pulmonary veins seems to be able to visualize high-grade and low-grade lesions, but larger catheter-controlled studies are needed for further assessment of the diagnostic accuracy and clinical reliability of this noninvasive method. (orig.) [German] Ziel: Mit steigender Anzahl von Radiofrequenzablationen (RFA) zur Behandlung des chronischen Vorhofflimmerns wird die Diagnostik von RFA assoziierten Pulmonalvenenstenosen zunehmend wichtiger. Ziel dieser Studie war es, die Moeglichkeit der Darstellung von Pulmonalvenenstenosen mittels der nichtinvasiven Multidetektor-Computertomographie zu untersuchen. Material und Methoden: 28 Patienten wurden im Anschluss an eine RFA-Behandlung untersucht. Die Untersuchung wurde an einem 4-Zeilen- (20 Patienten) bzw. 16-Zeilen- (8 Patienten) Multidetektor-CT (SOMATOM Volume Zoom bzw. Sensation 16, Siemens, Forchheim, Germany) mit retrospektivem Gating durchgefuehrt. Der

  5. A multidetector scintillation camera with 254 channels

    Sveinsdottir, E; Larsen, B; Rommer, P;

    1977-01-01

    A computer-based scintillation camera has been designed for both dynamic and static radionuclide studies. The detecting head has 254 independent sodium iodide crystals, each with a photomultiplier and amplifier. In dynamic measurements simultaneous events can be recorded, and 1 million total counts...... per second can be accommodated with less than 0.5% loss in any one channel. This corresponds to a calculated deadtime of 5 nsec. The multidetector camera is being used for 133Xe dynamic studies of regional cerebral blood flow in man and for 99mTc and 197 Hg static imaging of the brain....

  6. Evaluation of secondary spontaneous pneumothorax with multidetector CT

    The purpose of this article is to review the underlying causes of secondary pneumothoraces as observed on multidetector computed tomography (MDCT). Using examples from our institutional experience, we shall illustrate important diagnostic features to indicate the underlying lung disease. Understanding the varied range of conditions is important for accurate diagnosis and facilitation of patient management

  7. Multidetector CT in evaluating blood supply of hepatocellular carcinoma after transcatheter arterial chemoembolization

    Guan, Yong-Song; Zheng, Xiao-Hua; Zhou, Xiang-Ping; Huang, Juan; Sun, Long; Chen, Xian; Li, Xiao; He, Qing

    2004-01-01

    AIM: To assess the value of multidetector-row computed tomography (MDCT) in choosing retreatment methods of hepatocellular carcinoma (HCC) through evaluating the blood supply of low-density area of HCC after transcatheter arterial chemoembolization (TACE).

  8. Predicting Resectability of Pancreatic Head Cancer with Multi-Detector CT. Surgical and Pathologic Correlation

    Damien Olivié

    2007-11-01

    Full Text Available Context Computed tomography is widely used to pre-operatively evaluate patients with ductal carcinoma of the pancreas. Objective To prospectively evaluate the ability of multi-detector computed tomography to predict resectability of pancreatic head cancer. Patients Ninety-one consecutive patients (53 men, 38 women; mean age, 61 years referred to our department with a diagnosis of cancer of the head of the pancreas underwent a preoperative contrast enhanced triphasic 16- slice multi-detector computed tomography. Sixty-three were considered inoperable because of advanced local disease, metastatic disease, or poor surgical risk. Intervention Of the remaining 28 patients, 23 underwent a Whipple procedure, whereas 5 patients underwent a palliative procedure. Main outcome measures Surgical and pathologic reports were reviewed and compared to CT results. Results Of the 91 patients evaluated, 25% had successful resection of pancreatic head carcinoma; while only 5% had a palliative procedure. When compared to surgical outcome, the positive predictive value of multi-detector computed tomography for resectability was 100%. On the basis of pathologic results, the positive predictive value of multi-detector computed tomography for resectability fell to 83%, Four patients deemed resectable following multi-detector computed tomography had positive margins at pathology. Conclusion The positive predictive value of multi-detector computed tomography for resectable disease is lower when pathologic correlation, as opposed to surgical correlation, is used as the gold standard. Compared to previous studies, there was a lower rate of palliative surgery in our cohort.

  9. The utility of multi-detector computed tomography in the diagnosis of malignant pleural effusion in the patients with ovarian cancer

    Purpose: The purpose of this study was to retrospectively assess possible clinical predictors of malignant pleural effusion in patients with ovarian cancer. Materials and methods: This review was performed on 38 ovarian cancer patients that showed pleural effusion in a CT scan and who underwent thoracocentesis before treatment. CT scans were obtained using a 4-channel multi-detector CT scanner. Fisher's exact test was used to determine the probability of malignant pleural effusion as a function of; amount of ascites, lymph node enlargement, amount of pleural effusion, pleural nodules, and pleural thickening. Results: Sixteen (42.1%) of the 38 patients had malignant pleural effusion and malignant pleural effusion amounts were greater than those with nonmalignant effusion. Pleural nodules were more frequently found in the malignant pleural effusion group (eight [50%] patients) than in the nonmalignant group (zero [0%] patient) (p < 0.001). Supradiaphragmatic lymph node enlargement (with short axis diameter 1 cm or more) was more frequent in malignant group (12 [75%] patients) than in the nonmalignant group (two [9.1%] patients) (p < 0.001). Conclusion: The probability of malignant pleural effusion in patients with ovarian cancer was found to be correlated with the amount of pleural effusion, the presence of pleural nodules, and supradiaphragmatic lymph node enlargement.

  10. A new acquisition method with pacemaker resetting of coronary multidetector-row computed tomography for reduction of radiation dose in patients with pacemaker

    We proposed a new acquisition method of coronary multidetector-row CT (MDCT) achieved by pacing rate resetting and/or propranolol or verapamil injection in patients with a pacemaker. Coronary MDCT was undertaken in 57 patients with a pacemaker (DDD: 51, VVI: 6) and in 2975 patients with sinus rhythm as control using Aquilion 64 (Toshiba). Pacing rate was reset to 60 beats per minute (bpm) in DDD, and spontaneous beats were suppressed by propranolol injection. Pacing rate was reset to 70 bpm in atrial fibrillation with VVI, and spontaneous beats were suppressed by verapamil injection. Coronary MDCT was undertaken using as high a beam pitch (BP) as possible. When spontaneous beats were not suppressed, we selected the optimal gantry speed and BP to get the highest temporal resolution. Image quality makes no significant difference between pacemaker and sinus rhythm. When spontaneous beats were completely suppressed (all pacing), mean radiation dose and acquisition time, respectively, decreased by 33.0% and 35.2% in DDD compared with the method recommended by Heart Navi (by Toshiba), and they decreased by 38.1% and 25.9%, respectively, in VVI compared with the method recommended by Heart Navi. We could not estimate coronary stenosis in the proximal right coronary artery by lead artifacts in 30% of DDD pacemakers. In conclusion, the new method is useful for not only reducing radiation dose and acquisition time, but also for maintaining image quality in patients with a pacemaker. (author)

  11. Detection of hypervascular hepatocellular carcinoma: Comparison of multi-detector CT with digital subtraction angiography and Lipiodol CT

    Zheng, Xiao-Hua; Guan, Yong-Song; Zhou, Xiang-Ping; Huang, Juan; Sun, Long; Li, Xiao; Liu, Yuan

    2005-01-01

    AIM: The purpose of this study was to compare the diagnostic accuracy of biphasic multi-detector row helical computed tomography (MDCT), digital subtraction angiography (DSA) and Lipiodol computed tomography (CT) in detection of hypervascular hepatocellular carcinoma (HCC).

  12. Computed tomography angiography of carotid and coronary artery via a single-bolus injection protocol: a feasibility study using 320-row multidetector CT

    To investigate the feasibility of using a single-dose injection protocol in CT angiography (CTA) of the carotid and coronary artery with 320-row multidetector CT. A total of 82 consecutive patients with suspected carotid artery disease underwent an original CTA protocol aiming at capturing the extra-cranial carotid arteries and coronary arteries simultaneously using 320-row MDCT. The image quality, attenuation, and CNRs of the carotid and coronary arteries were assessed. The lag time (between two separated volumetric acquisitions) was compared between patients with and without cardiac venous opacification (CVO). The contrast medium volume and radiation dose were recorded. The image quality was 99.4 % diagnostic in carotid and 86.9 % in coronary artery segments. The mean attenuation of carotid and coronary arteries ranged from 462.2 Hu to 533.7 Hu, 415.9 Hu to 454.7 Hu respectively. The mean CNR of the carotid and coronary artery ranged from 15.8 to 18.9 and 17.7 to 20.4 respectively. The lag time in patients with and without CVO was 5.75 ± 1.64 s vs. 4.21 ± 1.14 s (p < 0.05). The mean radiation dose was 6.6 ± 4.1 mSv.The mean contrast media volume was 71.9 ± 9.1 ml. The carotid and coronary artery can be imaged simultaneously via our original single-dose injection CTA protocol using 320-row CT with adequate image quality. (orig.)

  13. Evaluation of left atrial function by multidetector computed tomography before left atrial radiofrequency-catheter ablation: Comparison of a manual and automated 3D volume segmentation method

    Wolf, Florian, E-mail: florian.wolf@meduniwien.ac.a [Department of Radiology, Medical University of Vienna, Vienna (Austria); Ourednicek, Petr [Philips Medical Systems, Prague (Czech Republic); Loewe, Christian [Department of Radiology, Medical University of Vienna, Vienna (Austria); Richter, Bernhard; Goessinger, Heinz David; Gwechenberger, Marianne [Department of Cardiology, Medical University of Vienna, Vienna (Austria); Plank, Christina; Schernthaner, Ruediger Egbert; Toepker, Michael; Lammer, Johannes [Department of Radiology, Medical University of Vienna, Vienna (Austria); Feuchtner, Gudrun M. [Department of Radiology, Innsbruck Medical University, Innsbruck (Austria); Institute of Diagnostic Radiology, University Hospital Zurich (Switzerland)

    2010-08-15

    Introduction: The purpose of this study was to compare a manual and automated 3D volume segmentation tool for evaluation of left atrial (LA) function by 64-slice multidetector-CT (MDCT). Methods and materials: In 33 patients with paroxysmal atrial fibrillation a MDCT scan was performed before radiofrequency-catheter ablation. Atrial function (minimal volume (LAmin), maximal volume (LAmax), stroke volume (SV), ejection fraction (EF)) was evaluated by two readers using a manual and an automatic tool and measurement time was evaluated. Results: Automated LA volume segmentation failed in one patient due to low LA enhancement (103HU). Mean LAmax, LAmin, SV and EF were 127.7 ml, 93 ml, 34.7 ml, 27.1% by the automated, and 122.7 ml, 89.9 ml, 32.8 ml, 26.3% by the manual method with no significant difference (p > 0.05) and high Pearsons correlation coefficients (r = 0.94, r = 0.94, r = 0.82 and r = 0.85, p < 0.0001), respectively. The automated method was significantly faster (p < 0.001). Interobserver variability was low for both methods with Pearson's correlation coefficients between 0.98 and 0.99 (p < 0.0001). Conclusions: Evaluation of LA volume and function with 64-slice MDCT is feasible with a very low interobserver variability. The automatic method is as accurate as the manual method but significantly less time consuming permitting a routine use in clinical practice before RF-catheter ablation.

  14. Multidetector CT of blunt abdominal trauma.

    Soto, Jorge A; Anderson, Stephan W

    2012-12-01

    The morbidity, mortality, and economic costs resulting from trauma in general, and blunt abdominal trauma in particular, are substantial. The "panscan" (computed tomographic [CT] examination of the head, neck, chest, abdomen, and pelvis) has become an essential element in the early evaluation and decision-making algorithm for hemodynamically stable patients who sustained abdominal trauma. CT has virtually replaced diagnostic peritoneal lavage for the detection of important injuries. Over the past decade, substantial hardware and software developments in CT technology, especially the introduction and refinement of multidetector scanners, have expanded the versatility of CT for examination of the polytrauma patient in multiple facets: higher spatial resolution, faster image acquisition and reconstruction, and improved patient safety (optimization of radiation delivery methods). In this article, the authors review the elements of multidetector CT technique that are currently relevant for evaluating blunt abdominal trauma and describe the most important CT signs of trauma in the various organs. Because conservative nonsurgical therapy is preferred for all but the most severe injuries affecting the solid viscera, the authors emphasize the CT findings that are indications for direct therapeutic intervention. PMID:23175542

  15. Multidetector-row computed tomography in the preoperative diagnosis of intestinal complications caused by clinically unsuspected ingested dietary foreign bodies: a case series emphasizing the use of volume rendering techniques

    Objective: the present study was aimed at describing a case series where a preoperative diagnosis of intestinal complications secondary to accidentally ingested dietary foreign bodies was made by multidetector-row computed tomography (MDCT), with emphasis on complementary findings yielded by volume rendering techniques (VRT) and curved multiplanar reconstructions (MPR). Materials and Methods: The authors retrospectively assessed five patients with surgically confirmed intestinal complications (perforation and/or obstruction) secondary to unsuspected ingested dietary foreign bodies, consecutively assisted in their institution between 2010 and 2012. Demographic, clinical, laboratory and radiological data were analyzed. VRT and curved MPR were subsequently performed. Results: preoperative diagnosis of intestinal complications was originally performed in all cases. In one case the presence of a foreign body was not initially identified as the causal factor, and the use of complementary techniques facilitated its retrospective identification. In all cases these tools allowed a better depiction of the entire foreign bodies on a single image section, contributing to the assessment of their morphology. Conclusion: although the use of complementary techniques has not had a direct impact on diagnostic performance in most cases of this series, they may provide a better depiction of foreign bodies' morphology on a single image section. (author)

  16. Multidetector-row computed tomography in the preoperative diagnosis of intestinal complications caused by clinically unsuspected ingested dietary foreign bodies: a case series emphasizing the use of volume rendering techniques

    Teixeira, Augusto Cesar Vieira; Torres, Ulysses dos Santos; Oliveira, Eduardo Portela de; Gual, Fabiana; Bauab Junior, Tufik, E-mail: usantor@yahoo.com.br [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Hospital de Base. Serv. de Radiologia e Diagnostico por Imagem; Westin, Carlos Eduardo Garcia [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Hospital de Base. Cirurgia Geral; Cardoso, Luciana Vargas [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Hospital de Base. Setor de Tomografia Computadorizada

    2013-11-15

    Objective: the present study was aimed at describing a case series where a preoperative diagnosis of intestinal complications secondary to accidentally ingested dietary foreign bodies was made by multidetector-row computed tomography (MDCT), with emphasis on complementary findings yielded by volume rendering techniques (VRT) and curved multiplanar reconstructions (MPR). Materials and Methods: The authors retrospectively assessed five patients with surgically confirmed intestinal complications (perforation and/or obstruction) secondary to unsuspected ingested dietary foreign bodies, consecutively assisted in their institution between 2010 and 2012. Demographic, clinical, laboratory and radiological data were analyzed. VRT and curved MPR were subsequently performed. Results: preoperative diagnosis of intestinal complications was originally performed in all cases. In one case the presence of a foreign body was not initially identified as the causal factor, and the use of complementary techniques facilitated its retrospective identification. In all cases these tools allowed a better depiction of the entire foreign bodies on a single image section, contributing to the assessment of their morphology. Conclusion: although the use of complementary techniques has not had a direct impact on diagnostic performance in most cases of this series, they may provide a better depiction of foreign bodies' morphology on a single image section. (author)

  17. Multidetector-row computed tomography (MDCT) for the diagnosis of hepatocellular carcinoma in cirrhotic candidates for liver transplantation: prevalence of radiological vascular patterns and histological correlation with liver explants

    To define the prevalence of different multidetector-row computed tomography (MDCT) vascular patterns and their histopathological correlation with liver explants, and to evaluate the accuracy of MDCT for the diagnosis of hepatocellular carcinoma (HCC). We retrospectively reviewed 125 cirrhotic patients imaged by MDCT before liver transplantation. Three main vascular patterns were identified: hypervascular lesion with washout (Hyper-L-Wo), hypervascular lesion without washout (Hyper-L) and non-hypervascular lesion (Hypo-L). Radiological findings were matched with histopathology of explants. Positive predictive value (PPV) and likelihood ratio (LR) were 95% and 18.66, respectively, for Hyper-L-Wo; 45% and 0.82 for Hyper-L; and 75% and 3 for Hypo-L of 20 mm or larger. Overall accuracy of MDCT for detection and characterisation of HCC was 89% and 43%, respectively. Sensitivity of MDCT for detection and characterisation was related to the lesion size, ranging from 78% (lesion smaller than 10 mm) to 98% (larger than 20 mm) and from 9% to 64%, respectively. MDCT established the accurate stage of disease in 46% of the patients, underestimated in 52% and overestimated in 2%. In cirrhotic patients, any Hyper-L-Wo detected by MDCT can be confidently considered to be HCC. Hyper-L larger than 10 mm and Hypo-L of 20 mm or larger are at high risk of HCC. However, even using MDCT and the newest imaging protocols, imaging underestimated the diagnosis of small HCC. (orig.)

  18. Multidetector-row computed tomography in the preoperative diagnosis of intestinal complications caused by clinically unsuspected ingested dietary foreign bodies: a case series emphasizing the use of volume rendering techniques

    Augusto Cesar Vieira Teixeira

    2013-12-01

    Full Text Available Objective The present study was aimed at describing a case series where a preoperative diagnosis of intestinal complications secondary to accidentally ingested dietary foreign bodies was made by multidetector-row computed tomography (MDCT, with emphasis on complementary findings yielded by volume rendering techniques (VRT and curved multiplanar reconstructions (MPR. Materials and Methods The authors retrospectively assessed five patients with surgically confirmed intestinal complications (perforation and /or obstruction secondary to unsuspected ingested dietary foreign bodies, consecutively assisted in their institution between 2010 and 2012. Demographic, clinical, laboratory and radiological data were analyzed. VRT and curved MPR were subsequently performed. Results Preoperative diagnosis of intestinal complications was originally performed in all cases. In one case the presence of a foreign body was not initially identified as the causal factor, and the use of complementary techniques facilitated its retrospective identification. In all cases these tools allowed a better depiction of the entire foreign bodies on a single image section, contributing to the assessment of their morphology. Conclusion Although the use of complementary techniques has not had a direct impact on diagnostic performance in most cases of this series, they may provide a better depiction of foreign bodies' morphology on a single image section.

  19. Non-invasive assessment of coronary artery bypass graft with retrospectively ECG-gated four-row multi-detector spiral computed tomography

    Marano, Riccardo; Storto, Maria Luigia; Maddestra, Nicola; Bonomo, Lorenzo [Department of Clinical Sciences and Bioimaging, Section of Radiology, University ' ' G. d' Annunzio' ' , Ospedale ' ' SS. Annunziata' ' , Via dei Vestini, 66100, Chieti (Italy)

    2004-08-01

    The purpose of this study was to assess the accuracy of four-row multi-detector CT (MDCT) in the evaluation of coronary artery bypass graft (CABG) in patients with at least a left internal mammary artery (LIMA) grafted to the left anterior descending artery (LAD), because of the conduit of choice in bypass surgery and the greater difficulty of evaluation with non-invasive diagnostic tools. Included in the study were 57 patients with a total of 122 grafts (95 arterial and 27 venous) who underwent MDCT (4 x 2.5-mm detector-collimation, 3-mm slice width, 1.5-mm reconstruction increment) with retrospective ECG gating. Twelve patients (21%) with high heart rates were given beta-blockers in order to obtain a heart rate {<=}70 bpm in all patients. The ECG-synchronized axial images, reconstructed in the mid-diastole, MPR, MIP and 3D-VR images were independently and blindly assessed by two radiologists for graft patency and presence of high grade stenosis. Conventional angiography was the standard of reference. MDCT correctly classified 92/94 patent grafts and 26/28 occluded grafts (sensitivity/specificity 93%/97.8%); sensitivity and specificity of MDCT for assessment of arterial grafts were 100 and 98.7% (77/78 patent grafts and 17/17 occluded grafts). Image quality was considered adequate for assessment of significant stenoses in 62/92 (67%) patent grafts, with a significant differences between LIMA and non-LIMA conduits (44/57 vs. 18/65; P=0.002), according to the coronary vessel area supplied (anterior>lateral>posterior-inferior wall; P=0.002). In the remaining 30 patent grafts (33%), the assessment of stenoses was hampered by surgical clips, calcifications and motion artifacts. Sensitivity and specificity of MDCT for detection of significant graft stenoses were 80 and 96%, respectively. Inter-observer agreement was good (K=0.73). MDCT seems to be a valuable diagnostic tool for non-invasive assessment of patency of both venous and arterial grafts. An accurate evaluation

  20. Evidence for lower variability of coronary artery calcium mineral mass measurements by multi-detector computed tomography in a community-based cohort-Consequences for progression studies

    Purpose: To compare the measurement variability for coronary artery calcium (CAC) measurements using mineral mass compared with a modified Agatston score (AS) or volume score (VS) with multi-detector CT (MDCT) scanning, and to estimate the potential impact of these methods on the design of CAC progression studies. Materials and methods: We studied 162 consecutive subjects (83 women, 79 men, mean age 51 ± 11 years) from a general Caucasian community-based cohort (Framingham Heart Study) with duplicate runs of prospective electrocardiographically-triggered MDCT scanning. Each scan was independently evaluated for the presence of CAC by four experienced observers who determined a 'modified' AS, VS and mineral mass. Results: Of the 162 subjects, CAC was detected in both scans in 69 (42%) and no CAC was detected in either scan in 72 (45%). Calcium scores were low in the 21/162 subjects (12%) for whom CAC was present in one but not the other scan (modified AS 0.96). However, the mean interscan variability was significantly different between mineral mass, modified AS, and VS (coefficient of variation 26 ± 19%, 41 ± 28% and 34 ± 25%, respectively; p < 0.04), with significantly smaller mean differences in pair-wise comparisons for mineral mass compared with modified AS (p < 0.002) or with VS (p < 0.03). The amount of CAC but not heart rate was an independent predictor of interscan variability (r = -0.638, -0.614 and -0.577 for AS, VS, and mineral mass, respectively; all p < 0.0001). The decreased interscan variability of mineral mass would allow a sample size reduction of 5.5% compared with modified AS for observational studies of CAC progression and for randomized clinical trials. Conclusion: There is significantly reduced interscan variability of CAC measurements with mineral mass compared with the modified AS or VS. However, the measurement variability of all quantification methods is predicted by the amount of CAC and is inversely correlated to the extent of partial

  1. Cardiac multidetector row CT before percutaneous coronary intervention as a treatment guide for chronic total occlusion cardiac multidetector row CT before percutaneous coronary intervention as a treatment guide for chronic total occlusion

    The goal of this study was to investigate imaging results from a coronary CT angiography (CCTA) in chronic coronary total occlusion (CTO) before percutaneous coronary intervention (PCI). In 74 patients with CTO, 34 patients was evaluated by using a 64-row multidetector CT scanner prior to the PCI and 40 control subjects with CTO, who only took PCI, were included. The multiplanar reformation of the heart chambers and three-dimensional CT images were used for determining an optimal view. We analyzed and evaluated the success rates of PCI, length of occluded vessel, calcified plaques, occluded side-branches, tapered occlusion, > 45 degrees angulation of occluded artery, and myocardial density < 50 Hounsfield unit (HU). Success rates of PCI in the two groups, the control group and the experimental group, were not statistically different (p > 0.05). The mean length of occluded arteries was measured as 25 +/- 11 mm and 26 cases (74%) had an occlusion length > 2 cm. Calcified plaques proximal to occlusion were detected in 19 cases (54%). Occluded side branches, tapered occlusion, > 45 degrees angulation of occluded artery, and myocardial density < 50 HU were in 11 cases (32%), 9 cases (27%), 6 cases (18%), and 5 cases (15%), respectively. Although there was no correlation between the CCTA findings before PCI and the success rate of PCI, common findings of CCTA in CTO included an occlusion length > 2 cm and calcified plaques proximal to occluded arteries.

  2. Cardiac multidetector row CT before percutaneous coronary intervention as a treatment guide for chronic total occlusion cardiac multidetector row CT before percutaneous coronary intervention as a treatment guide for chronic total occlusion

    Kim, Dong Hun; Choi, Dong Hyun [Dept. of Radiology, Chosun University Hospital, Gwangju (Korea, Republic of); Lee, Nae Hee [Dept. of Internal Medicine, Soonchunhyang University Bucheon Hospital, Bucheon (Korea, Republic of)

    2015-03-15

    The goal of this study was to investigate imaging results from a coronary CT angiography (CCTA) in chronic coronary total occlusion (CTO) before percutaneous coronary intervention (PCI). In 74 patients with CTO, 34 patients was evaluated by using a 64-row multidetector CT scanner prior to the PCI and 40 control subjects with CTO, who only took PCI, were included. The multiplanar reformation of the heart chambers and three-dimensional CT images were used for determining an optimal view. We analyzed and evaluated the success rates of PCI, length of occluded vessel, calcified plaques, occluded side-branches, tapered occlusion, > 45 degrees angulation of occluded artery, and myocardial density < 50 Hounsfield unit (HU). Success rates of PCI in the two groups, the control group and the experimental group, were not statistically different (p > 0.05). The mean length of occluded arteries was measured as 25 +/- 11 mm and 26 cases (74%) had an occlusion length > 2 cm. Calcified plaques proximal to occlusion were detected in 19 cases (54%). Occluded side branches, tapered occlusion, > 45 degrees angulation of occluded artery, and myocardial density < 50 HU were in 11 cases (32%), 9 cases (27%), 6 cases (18%), and 5 cases (15%), respectively. Although there was no correlation between the CCTA findings before PCI and the success rate of PCI, common findings of CCTA in CTO included an occlusion length > 2 cm and calcified plaques proximal to occluded arteries.

  3. Gd-EOB-DTPA-enhanced 3.0-Tesla MRI findings for the preoperative detection of focal liver lesions: Comparison with iodine-enhanced multi-detector computed tomography

    Park, Hyong-Hu; Goo, Eun-Hoe; Im, In-Chul; Lee, Jae-Seung; Kim, Moon-Jib; Kwak, Byung-Joon; Chung, Woon-Kwan; Dong, Kyung-Rae

    2012-12-01

    The safety of gadolinium-ethoxybenzyl-diethylenetriamine-pentaacetic-acid (Gd-EOB-DTPA) has been confirmed, but more study is needed to assess the diagnostic accuracy of Gd-EOB-DTPA-enhanced magnetic resonance imaging (MRI) in patients with a hepatocellular carcinoma (HCC) for whom surgical treatment is considered or with a metastatic hepatoma. Research is also needed to examine the rate of detection of hepatic lesions compared to multi-detector computed tomography (MDCT), which is used most frequently to localize and characterize a HCC. Gd-EOB-DTPA-enhanced MRI and iodine-enhanced MDCT imaging were compared for the preoperative detection of focal liver lesions. The clinical usefulness of each method was examined. The current study enrolled 79 patients with focal liver lesions who preoperatively underwent MRI and MDCT. In these patients, there was less than one month between the two diagnostic modalities. Imaging data were taken before and after contrast enhancement in both methods. To evaluate the images, we analyzed the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) in the lesions and the liver parenchyma. To compare the sensitivity of the two methods, we performed a quantitative analysis of the percentage signal intensity of the liver (PSIL) on a high resolution picture archiving and communication system (PACS) monitor (paired-samples t-test, p Rim enhancement was detected in all metastases (30/30). During the arterial and the delayed phases, good overall agreement between the gadoxetic-acid-enhanced MR and CT was observed (x2 test, p < 0.05). For the preoperative detection of focal liver lesions, Gd-EOB-DTPA-enhanced MRI had a higher diagnostic value and higher detection rate than iodine-enhanced MDCT. The arterial and the delayed dynamic enhancement patterns, and the gadoxetic-acid-enhanced MR imaging can provide information on the possible degree of cellular differentiation of a HCC, adenoma or metastatic tumor.

  4. Multidetector CT for Penetrating Torso Trauma: State of the Art.

    Dreizin, David; Munera, Felipe

    2015-11-01

    The use of computed tomography (CT) for hemodynamically stable victims of penetrating torso trauma continues to increase but remains less singular to the work-up than in blunt trauma. Research in this area has focused on the incremental benefits of CT within the context of evolving diagnostic algorithms and in conjunction with techniques such as laparoscopy, endoscopy, and angiographic intervention. This review centers on the current state of multidetector CT as a triage tool for penetrating torso trauma and the primacy of trajectory evaluation in diagnosis, while emphasizing diagnostic challenges that have lingered despite tremendous technological advances since CT was first used in this setting 3 decades ago. As treatment strategies have also changed considerably over the years in parallel with advances in CT, current management implications of organ-specific injuries depicted at multidetector CT are also discussed. PMID:26492022

  5. Traumatic lesions of corpus callosum: early multidetector CT findings

    Corpus callosum is one of the common sites of brain lesion, whose involvement is an indicator of a more severe prognosis, produced by traumatic shearing stresses resulting in diffuse axonal injury (DAI). Computed tomography (CT) in acute phase is considered to have a limited role for the detection of non-hemorrhagic or petechial hemorrhagic DAI lesions. New generation multidetector CT scanners allow faster acquisition of thinner-slice images and post-processing reformations. Three patients with severe closed head trauma underwent CT examinations using a multidetector scanner, a few hours and the day after injury. The review of original images with narrow window width and integration with reconstruction of thinner slices from raw-data and post-processing multiplanar reformations (MPR) helped to detect the onset of hypodense or predominantly hypodense areas of corpus callosum, not present at admission and afterwards confirmed by MRI. (orig.)

  6. Impact of heart rate and rhythm on radiation exposure in prospectively ECG triggered computed tomography

    Luecke, Christian, E-mail: neep@gmx.de [University of Leipzig – Heart Center, Department of Diagnostic and Interventional Radiology, Strümpellstrasse 39, D-04289, Leipzig (Germany); Andres, Claudia; Foldyna, Borek [University of Leipzig – Heart Center, Department of Diagnostic and Interventional Radiology, Strümpellstrasse 39, D-04289, Leipzig (Germany); Nagel, Hans Dieter [Wissenschaft and Technik für die Radiologie, Buchhholz i.d.N (Germany); Hoffmann, Janine; Grothoff, Matthias; Nitzsche, Stefan; Gutberlet, Matthias; Lehmkuhl, Lukas [University of Leipzig – Heart Center, Department of Diagnostic and Interventional Radiology, Strümpellstrasse 39, D-04289, Leipzig (Germany)

    2012-09-15

    Purpose: To evaluate the influence of different heart rates and arrhythmias on scanner performance, image acquisition and applied radiation exposure in prospectively ECG triggered computed tomography (pCT). Materials and methods: An ECG simulator (EKG Phantom 320, Müller and Sebastiani Elektronik GmbH, Munich, Germany) was used to generate different heart rhythms and arrhythmias: sinus rhythm (SR) at 45, 60, 75, 90 and 120/min, supraventricular arrhythmias (e.g. sinus arrhythmia, atrial fibrillation) and ventricular arrhythmias (e.g. ventricular extrasystoles), pacemaker-ECGs, ST-changes and technical artifacts. The analysis of the image acquisition process was performed on a 64-row multidetector CT (Brilliance, Philips Medical Systems, Cleveland, USA). A prospectively triggered scan protocol as used for routine was applied (120 kV; 150 mA s; 0.4 s rotation and exposure time per scan; image acquisition predominantly in end-diastole at 75% R-R-interval, in arrythmias with a mean heart rate above 80/min in systole at 45% of the R-R-interval; FOV 25 cm). The mean dose length product (DLP) and its percentage increase from baseline (SR at 60/min) were determined. Result: Radiation exposure can increase significantly when the heart rhythm deviates from sinus rhythm. ECG-changes leading to a significant DLP increase (p < 0.05) were bifocal pacemaker (61%), pacemaker dysfunction (22%), SVES (20%), ventricular salvo (20%), and atrial fibrillation (14%). Significantly (p < 0.05) prolonged scan time (>8 s) could be observed in bifocal pacemaker (12.8 s), pacemaker dysfunction (10.7 s), atrial fibrillation (10.3 s) and sinus arrhythmia (9.3 s). Conclusion: In prospectively ECG triggered CT, heart rate and rhythm can provoke different types of scanner performance, which can significantly alter radiation exposure and scan time. These results might have an important implication for indication, informed consent and contrast agent injection protocols.

  7. Calidad de imagen y dosis de radiación de la angiografía coronaria por tomografía computada multidetector con técnica de adquisición axial con gatillado prospectivo Imaging quality and effective radiation dose of prospective ECG-gated axial multidetector row computed tomography coronary angiography Objective

    Carlos Capuñay

    2011-09-01

    Full Text Available Objetivo. Determinar la calidad de imagen y la dosis de radiación efectiva (DRE de la angiografía coronaria por tomografía computada con adquisición con gatillado prospectivo (ACTC-P en comparación con la técnica de adquisición con gatillado retrospectivo (ACTC-R. Materiales y Métodos. Cuarenta y cinco estudios de ACTC-P fueron analizados en forma retrospectiva para la valoración de la calidad de imagen y DRE, y se compararon con 90 estudios de ACTC-R realizados sin (n = 45 y con (n = 45 modulación de la corriente del tubo de rayos X seleccionados de la base de datos acorde a características demográficas similares. La DRE se comparó entre los tres grupos. La calidad de imagen fue analizada en forma independiente por dos observadores y comparada con el grupo de ACTC-R modulada. Se determinó también la variabilidad interobservador. Resultados. No hubo diferencias significativas en la calidad de imagen entre los dos grupos. La variabilidad interobservador fue k=0,92 (IC 95%: 0,87 a 0,96. La DRE (media ± DS de la ACTC-P fue 2,88 ± 0,37 mSv comparado con 10,50 ± 1,15 mSv (p To determine the imaging quality and effective radiation dose (ERD of prospective ECG-gated multidetector row computed tomography coronary angiography (PMDCT-CA compared to retrospective ECG-gating (RMDCT-CA. Materials and Methods. Forty-five PMDCT-CA scans were retrospectively reviewed for assessing imaging quality and ERD, and compared to 90 RMDCT-CA scans performed with (n= 45 and without (n= 45 tube current modulation, selected from our database on the basis of similar demographical characteristics. ERD was compared between all three groups. Imaging quality was assessed by two independent observers and compared to the imaging quality of the group of RMDCT-CA scans performed with tube current modulation. The interobserver variability was also determined. Results. There were no significant differences in imaging quality between the two groups. Interobserver

  8. Multidetector CT and MRI in pancreatic diseases

    Multidetector CT and MRI are the most efficient non invasive techniques in the assessment of pancreatic diseases. As with MRI, multidetector CT has now become an all in one examination using 2 D and 3 D multiplanar reformations with the ability to perform with high accuracy: a) vascular assessment using MIP reconstruction and b) biliary and pancreatic ducts assessment using minIP reconstruction. This review compares and illustrates the respective advantages of MRI and multidetector CT in the assessment of pancreatic diseases. (authors)

  9. Endocardial-epicardial distribution of myocardial perfusion reserve assessed by multidetector computed tomography in symptomatic patients without significant coronary artery disease

    Kühl, Jørgen Tobias; George, Richard T; Mehra, Vishal C;

    2016-01-01

    AIM: Previous animal studies have demonstrated differences in perfusion and perfusion reserve between the subendocardium and subepicardium. 320-row computed tomography (CT) with sub-millimetre spatial resolution allows for the assessment of transmural differences in myocardial perfusion reserve...... (MPR) in humans. We aimed to test the hypothesis that MPR in all myocardial layers is determined by age, gender, and cardiovascular risk profile in patients with ischaemic symptoms or equivalent but without obstructive coronary artery disease (CAD). METHODS AND RESULTS: A total of 149 patients enrolled...... in the CORE320 study with symptoms or signs of myocardial ischaemia and absence of significant CAD by invasive coronary angiography were scanned with static rest and stress CT perfusion. Myocardial attenuation densities were assessed at rest and during adenosine stress, segmented into 3 myocardial...

  10. Early characterization of atherosclerotic coronary plaques with multidetector computed tomography in patients with acute coronary syndrome. A comparative study with intravascular ultrasound

    We compared 16-slice computed tomography (CT) with intravascular ultrasound (IVUS) in their ability to identify the culprit lesion, and to assess plaque characterization and vascular remodelling in acute coronary syndrome (ACS). Twenty patients were prospectively studied. Coronary plaque identification and characterization were compared using 16-slice CT and 40-MHz catheter-based IVUS. Minimum lumen area (MLA), cross-sectional vessel area (CVA) and vessel remodelling were determined for each comparable lesion. One hundred and sixty-nine segments were compared and 84 plaques analysed. Sixteen-slice CT detected 95% of culprit lesions (19/20). No feature suggestive of plaque rupture was detected by 16-slice CT. Attenuation measurements within all lesions revealed different values for hypoechoic (38 ± 33 HU), hyperechoic (94 ± 44 HU), and calcified plaques (561 ± 216 HU), (P < 0.001). Agreement between 16-slice CT and IVUS on measuring MLA and CVA was evaluated using Bland-Altman analysis. Pearson and intra-class coefficient (ICC) were 0.81 and 0.70 for MLA, and 0.81 and 0.36 for CVA, for 16-slice CT and IVUS, respectively. Agreement between both techniques for vessel positive remodelling was moderate (kappa 0.54, P < 0.001). Sixteen-slice CT has shown moderate accuracy in quantifying and characterizing coronary plaques compared with IVUS. Spatial resolution of 16-slice CT remains a major limitation, however, to accurately assess the complex lesions involved in ACS. (orig.)

  11. Early characterization of atherosclerotic coronary plaques with multidetector computed tomography in patients with acute coronary syndrome. A comparative study with intravascular ultrasound

    Iriart, Xavier; Dos-Santos, Pierre [Universite Bordeaux 2, Inserm U. 441 Atherosclerose, Bordeaux (France); Brunot, Sebastien [CHU de Bordeaux, Hopital du Haut-Leveque, Unite d' Imagerie Thoracique et Cardiovasculaire, Pessac (France); Unite de Soins Intensifs Cardiologiques, Pessac (France); Unite d' Imagerie Thoracique et Cardiovasculaire, Hopital Cardiologique, Pessac (France); Coste, Pierre; Leroux, Lionel [Universite Bordeaux 2, Inserm U. 441 Atherosclerose, Bordeaux (France); Unite de Soins Intensifs Cardiologiques, Pessac (France); Montaudon, Michel [Universite Bordeaux 2, Inserm U. 885 F 33076, Bordeaux (France); CHU de Bordeaux, Hopital du Haut-Leveque, Unite d' Imagerie Thoracique et Cardiovasculaire, Pessac (France); Labeque, Jean-Noel; Jais, Catherine [Unite de Soins Intensifs Cardiologiques, Pessac (France); Laurent, Francois [Universite Bordeaux 2, Inserm U. 885 F 33076, Bordeaux (France); CHU de Bordeaux, Hopital du Haut-Leveque, Unite d' Imagerie Thoracique et Cardiovasculaire, Pessac (France); Unite d' Imagerie Thoracique et Cardiovasculaire, Hopital Cardiologique, Pessac (France)

    2007-10-15

    We compared 16-slice computed tomography (CT) with intravascular ultrasound (IVUS) in their ability to identify the culprit lesion, and to assess plaque characterization and vascular remodelling in acute coronary syndrome (ACS). Twenty patients were prospectively studied. Coronary plaque identification and characterization were compared using 16-slice CT and 40-MHz catheter-based IVUS. Minimum lumen area (MLA), cross-sectional vessel area (CVA) and vessel remodelling were determined for each comparable lesion. One hundred and sixty-nine segments were compared and 84 plaques analysed. Sixteen-slice CT detected 95% of culprit lesions (19/20). No feature suggestive of plaque rupture was detected by 16-slice CT. Attenuation measurements within all lesions revealed different values for hypoechoic (38 {+-} 33 HU), hyperechoic (94 {+-} 44 HU), and calcified plaques (561 {+-} 216 HU), (P < 0.001). Agreement between 16-slice CT and IVUS on measuring MLA and CVA was evaluated using Bland-Altman analysis. Pearson and intra-class coefficient (ICC) were 0.81 and 0.70 for MLA, and 0.81 and 0.36 for CVA, for 16-slice CT and IVUS, respectively. Agreement between both techniques for vessel positive remodelling was moderate (kappa = 0.54, P < 0.001). Sixteen-slice CT has shown moderate accuracy in quantifying and characterizing coronary plaques compared with IVUS. Spatial resolution of 16-slice CT remains a major limitation, however, to accurately assess the complex lesions involved in ACS. (orig.)

  12. Can contrast-enhanced multi-detector computed tomography replace transesophageal echocardiography for the detection of thrombogenic milieu and thrombi in the left atrial appendage. A prospective study with 124 patients

    To assess the diagnostic value of contrast-enhanced multi-detector computed tomography (MD-CT) for identifying patients with left atrial appendage (LAA) thrombus or circulatory stasis. 124 patients with a history of atrial fibrillation and/or cerebral ischemia (83 men, mean age 58.6 ± 12.4 years) and with a clinical indication for MD-CT of the heart and for transesophageal echocardiography (TEE) were included in the study. LAA thrombus or thrombogenic milieu was visually identified in TEE and MD-CT. In addition, MD-CT was analyzed quantitatively measuring the Hounsfield units (HU) of the left atrium (LA), the LAA and the ascending aorta (AA), and calculating the HU ratios LAA/AA (HU [LAA/AA]) und LAA/LA (HU [LAA/LA]). Sensitivity, specificity, negative predictive value (NPV) and positive predictive value (PPV) were calculated. The prevalence of a thrombus or thrombogenic milieu as assessed by TEE was 21.8 %. The HU ratio was lower in patients with thrombus or thrombogenic milieu (HU [LAA/AA]: 0.590 ± 0.248 vs. 0.909 ± 0.141; p < 0.001 und HU [LAA/LA] 0.689 ± 0.366 vs. 1.082 ± 0.228; p < 0.001). For the diagnosis of thrombus or a thrombogenic milieu, visual analysis yielded a sensitivity of 81.5 %, a specificity of 96.9 %, a PPV of 87.5 % and a NPV of 95.2 %. By combining visual and quantitative analysis with one criterion being positive, the specificity decreased to 91.8 %, the sensitivity to 77.8 %, the PPV to 72.4 %, and the NPV to 94.9 %. Visual analysis of the LAA in the evaluation of thrombus or thrombogenic milieu yields a high NPV of 95.1 % and may especially be useful to rule out LAA thrombi in patients with contraindications for TEE. Additional calculation of HU ratios did not improve the diagnostic performance of MD-CT.

  13. Efficacy of pre-scan beta-blockade and impact of heart rate on image quality in patients undergoing coronary multidetector computed tomography angiography

    Shapiro, Michael D. [Cardiac MR PET CT Program, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Pena, Antonio J.; Nichols, John H. [Cardiac MR PET CT Program, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Worrell, Stewart [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Bamberg, Fabian [Cardiac MR PET CT Program, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Dannemann, Nina [Cardiac MR PET CT Program, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Abbara, Suhny; Cury, Ricardo C.; Brady, Thomas J. [Cardiac MR PET CT Program, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Hoffmann, Udo [Cardiac MR PET CT Program, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States)], E-mail: uhoffmann@partners.org

    2008-04-15

    Objective: While beta-blockers are routinely administered to patients prior to coronary computed tomography angiography (CTA), their effectiveness is unknown. We therefore assessed the efficacy of beta-blockade with regards to heart rate (HR) control and image quality in an unselected patient cohort. Methods: We studied 150 consecutive patients (104 men/46 female; mean age, 56 {+-} 13 years) referred for coronary CTA. Intravenous metoprolol (5-20 mg) was administered to patients with a HR >65 beats per minute (bpm). The goal HR was defined as an average HR <65 bpm without a single measurement above 68 bpm. Results: Overall, 45% (68/150) of patients met the HR criteria for beta-blocker administration of which 76% (52/68) received metoprolol (mean dose 12 {+-} 10 mg). Of the 52 patients who received beta-blocker versus the 98 who did not, 18 (35%) versus 62 (64%) patients achieved the goal HR, respectively. All patients who achieved the target HR had an evaluable CTA while five patients who did not achieve the target HR had at least one non-evaluable coronary artery due to motion artifact. There was also a significant reduction in any motion artifact among those who achieved the goal HR as compared to those who did not (p = 0.001). Logistic regression revealed an increase in the odds of stair step artifact of 11.6% (95% CI: 2.4% decrease, 27.5% increase) per 1 bpm increase in the standard deviation of scan HR. Conclusion: Overall, efficacy of beta-blocker administration to reach target HR is limited. Improvements in CT scanner temporal resolution are mandatory to achieve consistently high image quality independent of HR and beta-blocker administration.

  14. The Role Of Multidetector Computed Tomography In The Early Diagnosis Of Invasive Pulmonary Aspergıllosis In Patients With Febrile Neutropenia Undergoing Hematopoietic Stem Cell Transplantation

    Nazan Çiledağ

    2012-03-01

    Full Text Available OBJECTIVE: To evaluate the vessel involvement and the role of multidedector computed tomograpy (MDCT in the early diagnosis of invasive pulmonary aspergillosis (IPA at MDCT in autologous bone morrow transplantation patients with febrile neutropenia and antibiotic-resistant fever of unknown origin with clinically suspected IPA. METHODS: 74 pulmonary MDCT examinations of 37 consecutive hematopoietic stem cell transplantation patients with febrile neutropenia with clinically suspected IPA were retrospectively evaluated. RESULTS: The diagnosis of IPA was made according to according to the Fungal Infections Cooperative Group and the National Institute of Allergy and Infectious Diseases Mycoses Study Consensus Group criteria and 0, 14, 11 patients were diagnosed as proven, probable, possible IPA, respectively. Among 25 cases accepted as probable and possible IPA, all patients had pulmonary MDCT findings consistent with IPA. Remaining 12 patients were accepted as having fever of unknown origin (FUO and in these 12, MDCT showed patent vessel. In patients with probable/possible IPA, 72 focal pulmonary lesions were detected. In 41 of 72 (57%, vascular occlusion was detected. The CT halo sign was present in 25 of 41 (61% lesions. A clinical improvement, resolution of fever was observed following antifungal therapy in 19 (76% of 25 patients with probable/possible IPA. Six (25% patients diagnosed as IPA died during follow-up. Transplant related mortality at day 100 in patients with IPA and FUO were found to be 24% and 0%, respectively. CONCLUSION: In conclusion, MDCT has a potential role in early diagnosis of IPA by detection of vessel occlusion.

  15. Efficacy of pre-scan beta-blockade and impact of heart rate on image quality in patients undergoing coronary multidetector computed tomography angiography

    Objective: While beta-blockers are routinely administered to patients prior to coronary computed tomography angiography (CTA), their effectiveness is unknown. We therefore assessed the efficacy of beta-blockade with regards to heart rate (HR) control and image quality in an unselected patient cohort. Methods: We studied 150 consecutive patients (104 men/46 female; mean age, 56 ± 13 years) referred for coronary CTA. Intravenous metoprolol (5-20 mg) was administered to patients with a HR >65 beats per minute (bpm). The goal HR was defined as an average HR <65 bpm without a single measurement above 68 bpm. Results: Overall, 45% (68/150) of patients met the HR criteria for beta-blocker administration of which 76% (52/68) received metoprolol (mean dose 12 ± 10 mg). Of the 52 patients who received beta-blocker versus the 98 who did not, 18 (35%) versus 62 (64%) patients achieved the goal HR, respectively. All patients who achieved the target HR had an evaluable CTA while five patients who did not achieve the target HR had at least one non-evaluable coronary artery due to motion artifact. There was also a significant reduction in any motion artifact among those who achieved the goal HR as compared to those who did not (p = 0.001). Logistic regression revealed an increase in the odds of stair step artifact of 11.6% (95% CI: 2.4% decrease, 27.5% increase) per 1 bpm increase in the standard deviation of scan HR. Conclusion: Overall, efficacy of beta-blocker administration to reach target HR is limited. Improvements in CT scanner temporal resolution are mandatory to achieve consistently high image quality independent of HR and beta-blocker administration

  16. Multidetector Computed Tomography-Based Microstructural Analysis Reveals Reduced Bone Mineral Content and Trabecular Bone Changes in the Lumbar Spine after Transarterial Chemoembolization Therapy for Hepatocellular Carcinoma

    Takasu, Miyuki; Yamagami, Takuji; Nakamura, Yuko; Komoto, Daisuke; Kaichi, Yoko; Tani, Chihiro; Date, Shuji; Kiguchi, Masao; Awai, Kazuo

    2014-01-01

    Purpose It is well recognized that therapeutic irradiation can result in bone damage. However, long-term bone toxicity associated with computed tomography (CT) performed during interventional angiography has received little attention. The purpose of this study was to determine the prevalence of osteoporosis and trabecular microstructural changes in patients after transarterial chemoembolization (TACE) for hepatocellular carcinoma therapy using an interventional-CT system. Materials and Methods Spinal microarchitecture was examined by 64-detector CT in 81 patients who underwent TACE, 35 patients with chronic hepatitis, and 79 controls. For each patient, the volumetric CT dose index (CTDIv) during TACE (CTDIv (TACE)), the dose-length product (DLP) during TACE (DLP (TACE)), and CTDIv and DLP of routine dynamic CT scans (CTDIv (CT) and DLP (CT), respectively), were calculated as the sum since 2008. Using a three dimensional (3D) image analysis system, the tissue bone mineral density (tBMD) and trabecular parameters of the 12th thoracic vertebra were calculated. Using tBMD at a reported cutoff value of 68 mg/cm3, the prevalence of osteoporosis was assessed. Results The prevalence of osteoporosis was significantly greater in the TACE vs. the control group (39.6% vs. 18.2% for males, P<0.05 and 60.6% vs. 34.8% for females, P<0.01). Multivariate regression analysis demonstrated that sex, age, and CTDIv (CT) significantly affected the risk of osteoporosis. Of these indices, CTDIv (CT) had the highest area under the curve (AUC) (0.735). Correlation analyses of tBMD with cumulative radiation dose revealed weak correlations between tBMD and CTDIv (CT) (r2 = 0.194, P<0.001). Conclusion The prevalence of osteoporosis was significantly higher in post TACE patients than in control subjects. The cumulative radiation dose related to routine dynamic CT studies was a significant contributor to the prevalence of osteoporosis. PMID:25329933

  17. Computed tomography findings from patients with ARDS due to Influenza A (H1N1) virus-associated pneumonia

    Purpose: The purpose of this study was to retrospectively evaluate whether computed tomography (CT) findings have prognostic value for the prediction of mortality and severity of the clinical course in patients presenting with early stage of acute respiratory distress syndrome (ARDS) due to swine-origin influenza A (S-OIV). Materials and methods: Chest CT (16-/64-row multidetector CT) of 23 patients (of whom 9 patients died) were retrospectively reviewed by three independent blinded observers. The CT findings were graded on a 3-point scale (1: normal attenuation, 2: ground-glass attenuation, 3: consolidation). The extent of each abnormality was determined by visually estimating the percentage (to the nearest 10%) of the affected lung parenchyma in each zone and multiplied by the CT-score described above. Results: All patients presented with a mixture of bilateral patchy consolidations and ground glass opacities. Spearman rank correlation in evaluation of the presence and extent of lung abnormalities by the three different observers was good (correlation coefficient, 0.876–0.922; p < 0.001). The overall CT-score in survivors (mean, 96.0 (±26.2); range, 53–158) was significantly lower than that in non-survivors (mean, 116.2 (±14.0); range, 101–139). ROC analysis revealed an area under curve of 0.79 (p = 0.021) for the CT score with an optimal cutoff value of a CT-score of 100 for prediction of survival, with a sensitivity of 100% and a specificity of 64% (accuracy, 78%). For this optimal cutoff, Kaplan–Meier estimator showed a significant difference for the survival ratio (p = 0.011). Conclusion: In patients with severe ARDS due to S-OIV-infection, the CT-score has a prognostic value in the prediction of mortality.

  18. Photon intensity interferometry with multidetectors

    The technique of two-photon interferometry in heavy ion collisions at the intermediate energies is discussed and the importance of a new methodology, used in the treatment of the experimental data, is evidenced. For the first time, both the relative momentum, qrel, and the relative energy, q0, of the two correlated photons have been simultaneously used to extract the source size and lifetime of the emitting source. As an application, the performances of the BaF2 ball of the MEDEA multidetector as a photon intensity interferometer have been evaluated. The response of such a detector to correlated pairs of photons has been studied through full GEANT3 simulations. The effects of the experimental filter on the photon correlation function have been investigated, and the noise, induced in the correlation signal by cosmic radiation, neutral pion decay, and γ-conversion, has also been estimated. ((orig.))

  19. Temporal bone trauma and the role of multidetector CT in the emergency department.

    Zayas, Julio O; Feliciano, Yara Z; Hadley, Celene R; Gomez, Angel A; Vidal, Jorge A

    2011-10-01

    The temporal bone anatomy is complex, with many critical structures in close association with one another. The temporal bone region comprises cranial nerves V, VI, VII, and VIII; vascular structures such as the internal carotid and middle meningeal arteries; sigmoid sinus; jugular bulb; and sensorineural and membranous structures of the inner ear. Most temporal bone fractures are a result of high-energy blunt head trauma. Multidetector computed tomography (CT) plays a fundamental role in the initial evaluation of patients with polytrauma in the emergency department. Multidetector CT may help identify important structural injuries that may have devastating complications such as sensorineural hearing loss, conductive hearing loss, dizziness and balance dysfunction, perilymphatic fistulas, cerebrospinal fluid leaks, facial nerve paralysis, and vascular injury. Although classifying temporal bone fractures helps physicians understand and predict trauma-associated complications and guide treatment, identifying injury to critical structures is more important for guiding management and determining prognosis than is simply classifying temporal bone fractures into a general category. Many temporal bone fractures and complications may be readily identified and characterized at routine cervical, maxillofacial, and head multidetector CT performed in patients with polytrauma, without the need for dedicated temporal bone multidetector CT. Dedicated temporal bone multidetector CT should be considered when there is a high degree of suspicion for temporal bone fractures and no fractures are identified at head, cervical, or maxillofacial CT. PMID:21997992

  20. Development of the third generation ICT multi-detector sub-step equipment

    The multi-detector sub-step equipment, realizing the interpolation movement of the detector system, has been developed for studying the third generation industrial computed tomography (ICT). The projection data of size 1024 x 1024 can be gotten by 15 interpolation operations of the detector system when the number of detector array is 64. (authors)

  1. Method for Automatic Tube Current Selection for Obtaining a Consistent Image Quality and Dose Optimization in a Cardiac Multidetector CT

    To evaluate a quantitative method for individually adjusting the tube current to obtain images with consistent noise in electrocardiogram (ECG)-gated CT cardiac scans. The image noise from timing bolus and cardiac CT scans of 80 patients (Group A) who underwent a 64-row multidetector (MD) CT cardiac examination with patient-independent scan parameters were analyzed. A formula was established using the noise correlation between the timing bolus and cardiac scans. This formula was used to predict the required tube current to obtain the desired cardiac CT image noise based on the timing bolus noise measurement. Subsequently, 80 additional cardiac patients (Group B) were scanned with individually adjusted tube currents using an established formula to evaluate its ability to obtain accurate and consistent image noise across the patient population. Image quality was evaluated using score scale of 1 to 5 with a score of 3 or higher being clinically acceptable. Using the formula, we obtained an average CT image noise of 28.55 Hounsfield unit (HU), with a standard deviation of only 1.7 HU, as opposed to a target value of 28 HU. Image quality scores were 4.03 and 4.27 for images in Groups A and B, respectively, and there was no statistical difference between the image quality scores between the two groups. However, the average CT dose index (CTDIvol) was 30% lower for Group B. Adjusting the tube current based on timing bolus scans may provide a consistent image quality and dose optimization for cardiac patients of various body mass index values

  2. Multidetector calibration for mass spectrometers

    The International Atomic Energy Agency's Safeguards Analytical Laboratory has performed calibration experiments to measure the different efficiencies among multi-Faraday detectors for a Finnigan-MAT 261 mass spectrometer. Two types of calibration experiments were performed: (1) peak-shift experiments and (2) peak-jump experiments. For peak-shift experiments, the ion intensities were measured for all isotopes of an element in different Faraday detectors. Repeated measurements were made by shifting the isotopes to various Faraday detectors. Two different peak-shifting schemes were used to measure plutonium (UK Pu5/92138) samples. For peak-jump experiments, ion intensities were measured in a reference Faraday detector for a single isotope and compared with those measured in the other Faraday detectors. Repeated measurements were made by switching back-and-forth between the reference Faraday detector and a selected Faraday detector. This switching procedure is repeated for all Faraday detectors. Peak-jump experiments were performed with replicate measurements of 239Pu, 187Re, and 238U. Detector efficiency factors were estimated for both peak-jump and peak-shift experiments using a flexible calibration model to statistically analyze both types of multidetector calibration experiments. Calculated detector efficiency factors were shown to depend on both the material analyzed and the experimental conditions. A single detector efficiency factor is not recommended for each detector that would be used to correct routine sample analyses. An alternative three-run peak-shift sample analysis should be considered. A statistical analysis of the data from this peak-shift experiment can adjust the isotopic ratio estimates for detector differences due to each sample analysis

  3. Multidetector development: tests with a phthalocyanine crystal

    As part of a program to develop methods of using multidetectors for neutron crystallography, a total of 1277 diffracted intensities from a crystal of metal-free phthalocyanine were collected using a prototype 2-dimensional detector. Two different algorithms for peak integration are under consideration. These are described briefly and the results are compared in detail

  4. MARS - a multidetector array for reaction studies

    The proposal for MARS, a Multidetector Array for Reaction Studies is presented. MARS consists of a large, high-vacuum vessel enclosing an array of 128 scintillation detectors for use in studies of heavy-ion collisions at TASCC. The instrument will be funded and owned jointly by AECL and NSERC

  5. CHIMERA Multidetector at Laboratori Nazionali del Sud

    The installation of CHIMERA multidetector, designed in order to study central collisions in heavy ion reactions at intermediate energy, is going on at LNS and the first experiment with the forward part (688 telescopes) is running since May 1999. The aim of this contribution is to present the status of the project

  6. Instrumentation for multi-detector arrays

    R K Bhowmik

    2001-07-01

    The new generation of detector arrays require complex instrumentation and data acquisition system to ensure increased reliability of operation, high degree of integration, software control and faster data handling capability. The main features of some of the existing multi-detector arrays like MSU 4 array, Gammasphere and Eurogam are summarized. The instrumentation for the proposed INGA array in India is discussed.

  7. Esophageal injuries: Spectrum of multidetector row CT findings

    Lutio di Castelguidone, Elisabetta de [Department of Radiology, I.N.T., IRCCS Fondazione G. Pascale, Via M. Semmola, I-80131 Naples (Italy)]. E-mail: e.delutio@virgilio.it; Merola, Stefanella [Department of Diagnostic Imaging, ' A. Cardarelli' Hospital, I-80131 Naples (Italy); Pinto, Antonio [Department of Diagnostic Imaging, ' A. Cardarelli' Hospital, I-80131 Naples (Italy); Raissaki, Maria [Department of Radiology, University Hospital of Iraklion, University of Crete Medical School, P.O. Box 1352, 711 10 Iraklion Crete (Greece); Gagliardi, Nicola [Department of Diagnostic Imaging, ' A. Cardarelli' Hospital, I-80131 Naples (Italy); Romano, Luigia [Department of Diagnostic Imaging, ' A. Cardarelli' Hospital, I-80131 Naples (Italy)

    2006-09-15

    Background: Aim of this study is to illustrate the multidetector row computed tomographic findings related to oesophageal injuries and their significance for therapeutic decisions. Method: From April 2002 to April 2005 we studied 16 patients with suspected oesophageal injury. Ten patients underwent standard chest radiograph, while five patients with suspected foreign body ingestion were submitted to cervical plain film and gastrografin swallow study. All 16 patients underwent multidetector row CT examination. Results: In six patients with cervical, thoracic and abdominal trauma, CT showed the presence of thoracic traumatic lesions and findings suggestive of perforation of the oesophagus. In five patients with foreign body ingestion cervical radiography was positive in only one case, while CT showed the presence of a foreign body in all cases. In three patients with post-intubation complications, CT showed the presence of perioesophageal fluid collection containing small gas bubbles in two cases and an oesophageal-aortic fistula in one case. In the remaining two patients with suspected spontaneous oesophageal perforation, CT demonstrated an oesophageal wall oedema and thickening in one case, and oesophageal fluid distension with perioesophageal small bubbles gas and fluid in the second case. Conclusion: Oesophageal injuries, when complicated with perforation, constitute a life-threatening condition. Knowledge of the CT signs of oesophageal injuries has important implications for the role of imaging at the time of initial diagnosis.

  8. Association between coronary artery calcification score as assessed by multi-detector row computed tomography and cardiovascular risk factors%冠状动脉钙化积分与冠心病危险因素的相关性

    张剑; 韩雅玲; 荆全民; 王效增; 李毅; 张磊; 霍勇; 张岩

    2011-01-01

    Objective The coronary artery calcification (CAC) score determined by multi-detector row computed tomography ( MDCT) predicts the onset of coronary artery disease (CAD). In addition, cardiovascular risk factors also predict the mortality of CAD. Therefore, the aim of this study was to assess whether or not the CAC score is associated with cardiovascular risk factors. Methods A total of 9847 consecutive patients with suspected coronary artery disease underwent coronary angiography between January 2001 and March 2007 at 20 centers of China were enrolled. The subjects consisted of 311 consecutive patients with suspected CAD who underwent MDCT. The body mass index, blood pressure, blood glucose, and serum total cholesterol, triglyceride and low-density lipoprotein cholesterol ( LDL-C) and high-density lipoprotein cholesterol ( HDL-C) were measured. Results When the patients were divided into three groups according to the CAC score [low (0-12 IU), intermediate ( 13 - 445 ) and high ( 5* 446) ], the classification score was significantly associated with age, prevalence of cardiovascular history and diabetes mellitus and HDL-C. In multivariate logistic regression analysis, age ( P = 0. 013) and plasma levels of high-density lipoprotein cholesterol ( P = 0.020 ) remained significant independent variables for the classification. Conclusions Age, prevalence of cardiovascular history and diabetes mellitus and HDL-C were significantly associated with the classification according to the CAC score. The detection of CACS by MSCT could provide reliable and efective evidence for diagnosis of CHD in patients with cardiovascular risk factors.%目的 经多层冠状动脉CT检查测定的冠状动脉钙化积分对冠心病的诊断具有一定预测价值.而冠心病的危险因素与冠心病的发生、发展、结局和预后密切相关.我们旨在探讨冠状动脉钙化积分与冠心病诸多危险因素之间是否具有相关性.方法 入选2001年1月至2007年3

  9. Imaging of pancreatic adenocarcinoma with emphasis on multidetector CT

    Pancreatic adenocarcinoma is the fourth most frequent cause of cancer-related death. The incidence is increasing and the overall survival has altered little in recent years. Moreover, patients usually present late with inoperable disease and curative resection by standard pancreatico-duodenectomy (Whipple's procedure) is associated with significant morbidity. It should only be attempted in that small group of patients lacking radiological evidence of advanced disease. Despite the recent advances in body magnetic resonance imaging (MRI) and endoscopic ultrasound (EUS), computed tomography (CT) is the mainstay of staging in most centres and the recent development of multidetector CT machines (MDCT) has raised hope of an improvement in preoperative staging. This review focuses on the CT of pancreatic adenocarcinoma with particular emphasis on examination technique and on those criteria that determine resectability

  10. Role of multi-detector computed tomography (MDCT in management of post percutaneous nephrolithotomy (PCNL bleeding [v1; ref status: indexed, http://f1000r.es/205

    Arvind P Ganpule

    2013-11-01

    Full Text Available Objective: To evaluate the role of multidetector computerized tomography (MDCT angiography in post percutaneous nephrolithotomy (PCNL bleed and compare findings with conventional angiography (CA. Material and methods: We conducted a retrospective analysis of patients who had post PCNL bleeding and subsequently underwent a MDCT angiography followed by CA. We reviewed eight patients, who presented between January 2009 and January 2013. We performed a MDCT angiography on a 16 slice GE bright speed CT scanner. All angiographies were done by using the Digital Subtraction Angiography Suite. The angioembolisation, if required, was conducted by an interventional nephrologist, specializing in therapeutic embolisation. Results: The mean age of the patients was 42±17 years. Mean time of post PCNL bleed presentation was 10.06±7.9 days. Five patients presented with aneurysm and three presented with an AV fistula with pseudoaneurysm. The right renal unit was involved in six cases and the left in two cases. The lower polar segmental artery was involved in six cases and the upper polar artery in two cases. The CA and MDCT findings matched in all cases and the MDCT helped the clinician to assess and embolise the appropriate arterial tree. Conclusion: MDCT is rapid, reproducible and noninvasive. MDCT angiography performed in the setting of post PCNL bleeding provides an accurate assessment of the site and nature of bleeding. The MDCT angiography matched the CA findings in all patients in the present study.

  11. Multidetector CT diagnosis of massive hemobilia due to gallbladder polyposis in a child with metachromatic leukodystrophy

    Hemobilia secondary to gallbladder polyposis is rare in children but has been reported in a few children with metachromatic leukodystrophy. We present a case with preoperative multidetector computed tomography (MDCT) diagnosis of massive hemobilia caused by gallbladder polyposis in a patient with metachromatic leukodystrophy. Our report highlights the importance of both awareness of the association of gallbladder polyposis with other syndromes such as metachromatic leukodystrophy as well as the possibility of this entity presenting with life-threatening bleeding. (orig.)

  12. Program system for processing of spectra obtained on the multidetector correlation device (MUK)

    A program system used by evaluation of multidimensional coincidence spectra is described. The spectra recorded on magnetic tapes are obtained by means of multidetector correlation device (MUK). The angular correlation coefficients A22 and A44 for the given cascades of gamma transitions are the final result of the calculations. The system operates in DOS/ES system of the EC-1040 computer with the 1024 Kbyte memeory. All the codes are written in fortran language

  13. Multidetector CT diagnosis of massive hemobilia due to gallbladder polyposis in a child with metachromatic leukodystrophy

    Wanner, Matthew R.; Karmazyn, Boaz [Indiana University School of Medicine, Riley Hospital for Children, Department of Radiology and Imaging Sciences, Indianapolis, IN (United States); Fan, Rong [Indiana University School of Medicine, Riley Hospital for Children, Department of Pathology and Laboratory Medicine, Indianapolis, IN (United States)

    2015-12-15

    Hemobilia secondary to gallbladder polyposis is rare in children but has been reported in a few children with metachromatic leukodystrophy. We present a case with preoperative multidetector computed tomography (MDCT) diagnosis of massive hemobilia caused by gallbladder polyposis in a patient with metachromatic leukodystrophy. Our report highlights the importance of both awareness of the association of gallbladder polyposis with other syndromes such as metachromatic leukodystrophy as well as the possibility of this entity presenting with life-threatening bleeding. (orig.)

  14. Multidetector CT imaging of mechanical prosthetic heart valves: quantification of artifacts with a pulsatile in-vitro model

    Symersky, P.; Budde, R.P.; Westers, P.; Mol, B.A. de; Prokop, M.

    2011-01-01

    OBJECTIVES: Multidetector computed tomography (MDCT) can detect the cause of prosthetic heart valve (PHV) dysfunction but is hampered by valve-induced artifacts. We quantified artifacts of four PHV using a pulsatile in-vitro model and assessed the relation to leaflet motion and valve design. METHODS

  15. Multidetector CT imaging of mechanical prosthetic heart valves : quantification of artifacts with a pulsatile in-vitro model

    Symersky, Petr; Budde, Ricardo P. J.; Westers, Paul; de Mol, Bas A. J. M.; Prokop, Mathias

    2011-01-01

    Objectives Multidetector computed tomography (MDCT) can detect the cause of prosthetic heart valve (PHV) dysfunction but is hampered by valve-induced artifacts. We quantified artifacts of four PHV using a pulsatile in-vitro model and assessed the relation to leaflet motion and valve design. Methods

  16. Multidetector CT imaging of mechanical prosthetic heart valves: quantification of artifacts with a pulsatile in-vitro model

    P. Symersky; R.P.J. Budde; P. Westers; B.A.J.M. de Mol; M. Prokop

    2011-01-01

    Multidetector computed tomography (MDCT) can detect the cause of prosthetic heart valve (PHV) dysfunction but is hampered by valve-induced artifacts. We quantified artifacts of four PHV using a pulsatile in-vitro model and assessed the relation to leaflet motion and valve design. A Medtronic Hall ti

  17. A multidetector tomography protocol for follow-up of endovascular aortic aneurysm repair

    Roberto Moraes Bastos

    2011-01-01

    Full Text Available OBJECTIVE: The purpose of this study was to improve the use of 64-channel multidetector computed tomography using lower doses of ionizing radiation during follow-up procedures in a series of patients with endovascular aortic aneurysm repair. METHODS: Thirty patients receiving 5 to 29 months of follow-up after endovascular aortic aneurysm repair were analyzed using a 64-channel multidetector computed tomography device by an exam that included pre-and postcontrast with both arterial and venous phases. Leak presence and type were classified based on the exam phase. RESULTS: Endoleaks were identified in 8/30 of cases; the endoleaks in 3/8 of these cases were not visible in the arterial phases of the exams. CONCLUSION: The authors conclude that multidetector computed tomography with pre-contrast and venous phases should be a part of the ongoing follow-up of patients undergoing endovascular aortic aneurysm repair. The arterial phase can be excluded when the aneurism is stable or regresses. These findings permit a lower radiation dose without jeopardizing the correct diagnosis of an endoleak.

  18. Prevalence of thoracolumbar vertebral fractures on multidetector CT

    Objective: To evaluate the prevalence of osteoporotic vertebral fractures in patients undergoing multidetector computed tomography (MDCT) of the chest and/or abdomen. Materials and methods: 323 consecutive patients (196 males, 127 females) with a mean age of 62.6 years (range 20-88) who had undergone chest and/or abdominal MDCT were evaluated. Sagittal reformats of the spine obtained from thin section datasets were reviewed by two radiologists and assessed for vertebral fractures. Morphometric analysis using electronic calipers was performed on vertebral bodies which appeared abnormal upon visual inspection. A vertebral body height loss of 15% or more was considered a fracture and graded as mild (15-24%), moderate (25-49%) or severe (more than 50%). Official radiology reports were reviewed and whether the vertebral fractures had been reported or not was noted. Results: 31 out of 323 patients (9.5%) had at least 1 vertebral fracture and 7 of those patients had multiple fractures for a total of 41 fractures. Morphometric grading revealed 10 mild, 16 moderate and 15 severe fractures. Prevalence was higher in women (14.1%) than men (6.6%) and increased with patients age with a 17.1% prevalence in post-menopausal women. Only 6 out 41 vertebral fractures (14.6%) had been noted in the radiology final report while the remaining 35 (85.45) had not. Conclusion: although vertebral fractures represent frequent incidental findings on multidetector CT studies and may be easily identified on sagittal reformats, they are often underreported by radiologists, most likely because of unawareness of their clinical importance.

  19. Prevalence of thoracolumbar vertebral fractures on multidetector CT

    Bartalena, Tommaso [Department of Radiology, S. Orsola University Hospital, Via Massarenti 9 - 40138 Bologna (Italy)], E-mail: t.bartalena@email.it; Giannelli, Giovanni; Rinaldi, Maria Francesca [Department of Radiology, S. Orsola University Hospital, Via Massarenti 9 - 40138 Bologna (Italy); Rimondi, Eugenio [Department of Radiology, Rizzoli Orthopaedic Institute, Via G.C. Pupilli 1 - 40136 Bologna (Italy); Rinaldi, Giovanni [Department of Radiology, S. Orsola University Hospital, Via Massarenti 9 - 40138 Bologna (Italy); Sverzellati, Nicola [Department of Clinical Sciences, Section of Radiology, University of Parma, Via Gramsci, 14 - 43100 Parma (Italy); Gavelli, Giampaolo [Department of Radiology, S. Orsola University Hospital, Via Massarenti 9 - 40138 Bologna (Italy)

    2009-03-15

    Objective: To evaluate the prevalence of osteoporotic vertebral fractures in patients undergoing multidetector computed tomography (MDCT) of the chest and/or abdomen. Materials and methods: 323 consecutive patients (196 males, 127 females) with a mean age of 62.6 years (range 20-88) who had undergone chest and/or abdominal MDCT were evaluated. Sagittal reformats of the spine obtained from thin section datasets were reviewed by two radiologists and assessed for vertebral fractures. Morphometric analysis using electronic calipers was performed on vertebral bodies which appeared abnormal upon visual inspection. A vertebral body height loss of 15% or more was considered a fracture and graded as mild (15-24%), moderate (25-49%) or severe (more than 50%). Official radiology reports were reviewed and whether the vertebral fractures had been reported or not was noted. Results: 31 out of 323 patients (9.5%) had at least 1 vertebral fracture and 7 of those patients had multiple fractures for a total of 41 fractures. Morphometric grading revealed 10 mild, 16 moderate and 15 severe fractures. Prevalence was higher in women (14.1%) than men (6.6%) and increased with patients age with a 17.1% prevalence in post-menopausal women. Only 6 out 41 vertebral fractures (14.6%) had been noted in the radiology final report while the remaining 35 (85.45) had not. Conclusion: although vertebral fractures represent frequent incidental findings on multidetector CT studies and may be easily identified on sagittal reformats, they are often underreported by radiologists, most likely because of unawareness of their clinical importance.

  20. Computed tomography of renal cell carcinoma in patients with terminal renal impairment

    Purpose: An increased incidence of renal tumors has been observed in patients with end-stage-renal-disease (ESRD). The very strong association with acquired renal cystic disease (ACRD) and increased incidence of the renal tumors (conventional renal cell carcinoma (CRCC), papillary renal cell carcinoma (PRCC) or papillary renal cell adenoma (PRCA)) was reported. This study discusses the role of computed tomography (CT) in detecting renal tumors in patients with renal impairment: pre-dialysis, those receiving dialysis or with renal allograft transplants. Materials and methods: Ten patients (nine male, one female) with renal cell tumors were enrolled into a retrospective study; two were new dialysis patients, three on long-term dialysis, and five were renal transplant recipients with history of dialysis. All patients underwent helical CT, a total of 11 procedures were performed. Sixteen-row detector system was used five times, and a 64-row detector system for the six examinations. All patients underwent nephrectomy of kidney with suspected tumor, 15 nephrectomies were performed, and 1 kidney was assessed during autopsy. CT findings were compared with macroscopic and microscopic assessments of the kidney specimen in 16 cases. Results: Very advanced renal parenchyma atrophy with small cysts corresponding to ESRD was found in nine patients, chronic pyelonephritis in remained one. A spontaneously ruptured tumor was detected incidentally in one case, patient died 2 years later. In the present study, 6.25% (1/16) were multiple PRCA, 12.5% (2/16) were solitary PRCC, 12.5% tumors (2/16) were solitary conventional renal cell carcinomas (CRCC's), 12.5% tumors (2/16) were multiple conventional renal cell carcinomas (CRCC's), 25% (4/16) were CRCC's combined with multiple papillary renal cell carcinomas with adenomas (PRCC's and PRCA's), and 25% (4/16) of the tumors were multiple PRCC's combined with PRCA's without coexisting CRCC's. Bilateral renal tumors were found in our study

  1. Computed tomography of renal cell carcinoma in patients with terminal renal impairment

    Ferda, Jiri [Department of Radiology, Charles University Hospital Plzen, Alej Svobody 80, CZ-306 40 Plzen (Czech Republic)], E-mail: ferda@fnplzen.cz; Hora, Milan [Department of Urology, Charles University Hospital Plzen, Dr. Edvarda Benese 13, CZ-306 40 Plzen (Czech Republic); Hes, Ondrej [Institut of Pathology, Charles University Hospital Plzen, Alej Svobody 80, CZ-306 40 Plzen (Czech Republic); Reischig, Tomas [Department of Internal Medicine, Nephrology Unit, Charles University Hospital Plzen, Alej Svobody 80, CZ-306 40 Plzen (Czech Republic); Kreuzberg, Boris; Mirka, Hynek; Ferdova, Eva; Ohlidalova, Kristyna; Baxa, Jan [Department of Radiology, Charles University Hospital Plzen, Alej Svobody 80, CZ-306 40 Plzen (Czech Republic); Urge, Tomas [Department of Urology, Charles University Hospital Plzen, Dr. Edvarda Benese 13, CZ-306 40 Plzen (Czech Republic)

    2007-08-15

    Purpose: An increased incidence of renal tumors has been observed in patients with end-stage-renal-disease (ESRD). The very strong association with acquired renal cystic disease (ACRD) and increased incidence of the renal tumors (conventional renal cell carcinoma (CRCC), papillary renal cell carcinoma (PRCC) or papillary renal cell adenoma (PRCA)) was reported. This study discusses the role of computed tomography (CT) in detecting renal tumors in patients with renal impairment: pre-dialysis, those receiving dialysis or with renal allograft transplants. Materials and methods: Ten patients (nine male, one female) with renal cell tumors were enrolled into a retrospective study; two were new dialysis patients, three on long-term dialysis, and five were renal transplant recipients with history of dialysis. All patients underwent helical CT, a total of 11 procedures were performed. Sixteen-row detector system was used five times, and a 64-row detector system for the six examinations. All patients underwent nephrectomy of kidney with suspected tumor, 15 nephrectomies were performed, and 1 kidney was assessed during autopsy. CT findings were compared with macroscopic and microscopic assessments of the kidney specimen in 16 cases. Results: Very advanced renal parenchyma atrophy with small cysts corresponding to ESRD was found in nine patients, chronic pyelonephritis in remained one. A spontaneously ruptured tumor was detected incidentally in one case, patient died 2 years later. In the present study, 6.25% (1/16) were multiple PRCA, 12.5% (2/16) were solitary PRCC, 12.5% tumors (2/16) were solitary conventional renal cell carcinomas (CRCC's), 12.5% tumors (2/16) were multiple conventional renal cell carcinomas (CRCC's), 25% (4/16) were CRCC's combined with multiple papillary renal cell carcinomas with adenomas (PRCC's and PRCA's), and 25% (4/16) of the tumors were multiple PRCC's combined with PRCA's without coexisting CRCC

  2. Multidetector CT of the Pancreas

    Rossella Graziani

    2008-07-01

    Full Text Available Purpose. This book is a practical overview of pancreatic computer tomography (CT based on the large experience of the contributors. It is dedicated to Carlo Procacci a well known radiologist of Verona who died in 2004. Content. The book is divided into 10 chapters covering the different aspects of diagnostic CT of the pancreas. The various radiological aspects of acute and chronic pancreatitis, exocrine and endocrine pancreatic cancer (adenocarcinoma, neuroendocrine tumors, cystic cancer, rare neoplasms, traumatic abnormalities, imaging aspects of the gland after surgery and finally imaging findings after pancreas transplantation are reported in detail. Comment. We would emphasize that the characteristics of imaging of the common pancreatic diseases are described in addition to unusual or rare aspects of pancreatic pathology. The iconography is very rich and it is of excellent quality and it will help the radiologist to deal with individual cases particularly complex. Another important aspect of the book is that the initial approach of the various pancreatic diseases is based on clinical, surgical and pathological aspects and their relationship with imaging findings. Limitation. It is a great pity that the book for its importance is written in Italian language and for this reason it can not have an international appreciation. Final note. The radiologists will find in the book all the information useful for their daily practice. The internists, gastroenterologists and surgeons also will found useful information to better understand the information given by the modern CT radiology.

  3. [Computed tomography of the heart

    Kristensen, T.S.; Kofoed, K.F.; der, Recke P. von;

    2009-01-01

    Noninvasive evaluation of the coronary arteries by multi-detector row computed tomography is a promising new alternative to conventional invasive coronary angiography. This article describes the technical background, methods, limitations and clinical applications and reviews current literature th...

  4. Fabrication process of ionization chamber multidetector and multidetector got by this process

    The multidetector ionization chamber walls are fixed one related to the others and carried together with a tool above a resin bath to polymerize. After resin hardening, the detector includes resin basis. To contain the resin bath, the realization of a mould cut in a massive resin block are been provided for. This allows for its manutention all along the process without any deterioration risk

  5. Diagnóstico auxiliado por computador na detecção de nódulos pulmonares pela tomografia computadorizada com múltiplos detectores: estudo preliminar de 24 casos Detection of pulmonary nodules by computer-aided diagnosis in multidetector computed tomography: preliminary study of 24 cases

    Julia Capobianco; Dany Jasinowodolinski; Gilberto Szarf

    2008-01-01

    OBJETIVOS: Avaliar o desempenho de um programa para auxílio na detecção de nódulos pulmonares em tomografia computadorizada com múltiplos detectores (TCMD). MÉTODOS: Foram avaliadas 24 tomografias computadorizadas de tórax consecutivas realizadas no Centro de Medicina Diagnóstica Fleury no período de 07/10/2006 a 19/10/2006 usando um tomógrafo helicoidal multidetectores de 64 canais. O estudo compreendeu 12 pacientes do sexo feminino e 12 do sexo masculino, com idades variando entre 35 e 77 a...

  6. Virtual colonoscopy with multidetector computerized tomography

    If patients refuse to be examined by conventional colonoscopy, virtual colonoscopy, i.e. CT colonography using spiral CT and 3D reconstruction of the relevant CT information for assessment of the colon and detection of pathological masses, is an appropriate approach. The article summarizes the examinations, CT findings and verified conclusions of 20 cases where patients were examined by multi-detector CT. In three patients, suspected polyps were confirmed by surgery (15% correct positive results). In one female patient, 10% false positive results were obtained, as well as 5% false negative results in the same patient (one polyp of about 3 mm in diameter). The sensitivity and specificity of the virtual colonoscopy do not yet match the standards of conventional colonoscopy. (orig./CB)

  7. Evaluation of tracheal bronchus in Chinese children using multidetector CT

    Ming, Zhu; Lin, Zhang [Shanghai Children' s Medical Center, Department of Radiology, Shanghai (China)

    2007-12-15

    Tracheal bronchus is a congenital bronchial anomaly. The diagnosis should be considered early in intubated patients. Multidetector computed tomography (MDCT) is the newest modality for evaluating tracheal bronchus. To evaluate the utility of 16-slice MDCT in children with tracheal bronchus and to characterize the frequency of tracheal bronchus in children with congenital heart disease. From June 2005 to May 2007, 3,187 consecutive children (1,124 with congenital heart disease and 2,063 without congenital heart disease) underwent MDCT examination. Minimum-intensity projection reconstruction was performed to show the tracheobronchial tree in every case. Tracheal bronchus was found in 42 children (3.74%) with congenital heart disease but in only 6 children (0.29%) without congenital heart disease. Among the 48 children with tracheal bronchus, 45 had right-side tracheal bronchus and 3 had bilateral tracheal bronchi with heterotaxy syndrome. The diagnostic sensitivity of MDCT was 100% (48/48). MDCT is a reliable imaging technique for the diagnosis of tracheal bronchus. Our data showed that right-side tracheal bronchus was more common and bilateral tracheal bronchi usually occurred with heterotaxy syndrome. In addition, tracheal bronchus often occurred with congenital heart disease. The angle between the tracheal bronchus and the trachea is important and should be measured. (orig.)

  8. The Role of Multidetector CT in the Diagnosis of Retroperitoneal Fibrosis: Report of a Case

    Herein, we report a 40-year old man who presented with flank and abdominal pain with dilatation of the bilateral pyelocalyceal system detected in ultrasonography. Computed Tomography (CT) scan showed a soft tissue mass at the level of the fourth and fifth lumbar vertebrae in the retroperitoneal region. There were no blood flow signals in 64-slice multidetector CT (MDCT) which confirms the Retroperitoneal Fibrosis (RPF). Pathological examination showed infiltration of plasma cells, macrophages, lymphocytes and eosinophils accompanied by fibrosis, which is consistent with idiopathic RPF. In conclusion, 64-slice MDCT imaging is useful in the diagnosis of RPF

  9. On the cosmic-ray induced background in neutral pion production measurements with a BaF2 multidetector

    The problem of the cosmic-ray induced background in neutral pion production measurements with barium fluoride multidetectors is discussed. As a reference example, the response to cosmic rays of the MEDEA photon spectrometer is studied. The interaction of the cosmic radiation with the experimental filter has been treated by means of full Monte Carlo computer simulations with the GEANT3 code. The results of the simulations are compared with experimental data and general criteria to minimize the cosmic background are discussed. ((orig.))

  10. Intracardiac Eustachian Valve Cyst in an Adult Detected with Other Cardiac Anomalies: Usefulness of Multidetector CT in Diagnosis

    Cho, Hyung JI; Jung, Jung Im; Kim, Hwan Wook; Lee, Kyo Young

    2012-01-01

    We present an unusual case of an intracardiac Eustachian valve cyst observed concurrently with atresia of the coronary sinus ostium, a persistent left superior vena cava (LSVC) and a bicuspid aortic valve. There have been several echocardiographic reports of Eustachian valve cysts; however, there is no report of multidetector computed tomography (MDCT) findings related to a Eustachian valve cyst. Recently, we observed a Eustachian valve cyst diagnosed on MDCT showing a hypodense cyst at the c...

  11. A pictorial review of acute aortic syndrome: discriminating and overlapping features as revealed by ECG-gated multidetector-row CT angiography

    Ueda, Takuya; Chin, Anne; Petrovitch, Ivan; Fleischmann, Dominik

    2012-01-01

    Background The term "acute aortic syndrome" (AAS) encompasses a spectrum of life-threatening conditions characterized by acute aortic pain. AAS traditionally embraces three abnormalities including classic aortic dissection, intramural haematoma, and penetrating atherosclerotic ulcer. Although the underlying etiologies and conditions predisposing to AAS are diverse, the clinical features are indistinguishable. Methods Multidetector-row computed tomography (CT) with electrocardiographic gating ...

  12. Trapping volumetric measurement by multidetector CT in chronic obstructive pulmonary disease: Effect of CT threshold

    Wang, Xiaohua; Yuan, Huishu [Department of Radiology, Peking University Third Hospital, Beijing 100191 (China); Duan, Jianghui [Medical School, Peking University, Beijing 100191 (China); Du, Yipeng; Shen, Ning; He, Bei [Department of Respiration Internal Medicine, Peking University Third Hospital, Beijing 100191 (China)

    2013-08-15

    Purpose: The purpose of this study was to evaluate the effect of various computed tomography (CT) thresholds on trapping volumetric measurements by multidetector CT in chronic obstructive pulmonary disease (COPD).Methods: Twenty-three COPD patients were scanned with a 64-slice CT scanner in both the inspiratory and expiratory phase. CT thresholds of −950 Hu in inspiration and −950 to −890 Hu in expiration were used, after which trapping volumetric measurements were made using computer software. Trapping volume percentage (Vtrap%) under the different CT thresholds in the expiratory phase and below −950 Hu in the inspiratory phase was compared and correlated with lung function.Results: Mean Vtrap% was similar under −930 Hu in the expiratory phase and below −950 Hu in the inspiratory phase, being 13.18 ± 9.66 and 13.95 ± 6.72 (both lungs), respectively; this difference was not significant (P= 0.240). Vtrap% under −950 Hu in the inspiratory phase and below the −950 to −890 Hu threshold in the expiratory phase was moderately negatively correlated with the ratio of forced expiratory volume in one second to forced vital capacity and the measured value of forced expiratory volume in one second as a percentage of the predicted value.Conclusions: Trapping volumetric measurement with multidetector CT is a promising method for the quantification of COPD. It is important to know the effect of various CT thresholds on trapping volumetric measurements.

  13. Can contrast-enhanced multi-detector computed tomography replace transesophageal echocardiography for the detection of thrombogenic milieu and thrombi in the left atrial appendage. A prospective study with 124 patients; Kann die kontrastmittelverstaerkte Mehrzeilen-Computertomografie die transoesophageale Echokardiografie bei der Detektion von thrombogenem Milieu und Vorhofohrthromben ersetzen? Eine prospektive Studie mit 124 Patienten

    Homsi, R.; Luetkens, J.A.; Schild, H.H.; Naehle, C.P. [Bonn Univ. (Germany). Dept. of Radiology; Nath, B. [SHG-KLliniken Voelklingen (Germany). Dept. of Medicine I - Cardiology; Schwab, J.O. [Bonn Univ. (Germany). Dept. of Medicine I - Cardiology

    2016-01-15

    To assess the diagnostic value of contrast-enhanced multi-detector computed tomography (MD-CT) for identifying patients with left atrial appendage (LAA) thrombus or circulatory stasis. 124 patients with a history of atrial fibrillation and/or cerebral ischemia (83 men, mean age 58.6 ± 12.4 years) and with a clinical indication for MD-CT of the heart and for transesophageal echocardiography (TEE) were included in the study. LAA thrombus or thrombogenic milieu was visually identified in TEE and MD-CT. In addition, MD-CT was analyzed quantitatively measuring the Hounsfield units (HU) of the left atrium (LA), the LAA and the ascending aorta (AA), and calculating the HU ratios LAA/AA (HU [LAA/AA]) und LAA/LA (HU [LAA/LA]). Sensitivity, specificity, negative predictive value (NPV) and positive predictive value (PPV) were calculated. The prevalence of a thrombus or thrombogenic milieu as assessed by TEE was 21.8 %. The HU ratio was lower in patients with thrombus or thrombogenic milieu (HU [LAA/AA]: 0.590 ± 0.248 vs. 0.909 ± 0.141; p < 0.001 und HU [LAA/LA] 0.689 ± 0.366 vs. 1.082 ± 0.228; p < 0.001). For the diagnosis of thrombus or a thrombogenic milieu, visual analysis yielded a sensitivity of 81.5 %, a specificity of 96.9 %, a PPV of 87.5 % and a NPV of 95.2 %. By combining visual and quantitative analysis with one criterion being positive, the specificity decreased to 91.8 %, the sensitivity to 77.8 %, the PPV to 72.4 %, and the NPV to 94.9 %. Visual analysis of the LAA in the evaluation of thrombus or thrombogenic milieu yields a high NPV of 95.1 % and may especially be useful to rule out LAA thrombi in patients with contraindications for TEE. Additional calculation of HU ratios did not improve the diagnostic performance of MD-CT.

  14. Multi-detector CT (MDCT in bowel and mesenteric injury

    Vajjalla Ravikumar

    2013-04-01

    Full Text Available Objectives: To evaluate multi-detector CT (MDCT findings in bowel and mesenteric injury due to blunt abdominal trauma.Method: Retrospective evaluation of MDCT scan reports of patients admitted in Hamad Medical Corporation, Doha, Qatar with bowel and mesenteric injury during the period of January 2005 to April 2008.Results: MDCT, without using oral contrast, clearly demonstrated various specific and less specific findings of bowel and mesenteric injury.Conclusion: Multi-detector CT is an excellent diagnostic modality in bowel and mesenteric injury. Routine administration of oral contrast agent is not mandatory for initial evaluation of these patients.

  15. Multidetector CT angiography in Takayasu arteritis

    Khandelwal, Niranjan; Kalra, Naveen [Department of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India); Garg, Mandeep Kumar, E-mail: gargmandeep@hotmail.com [Department of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India); Kang, Mandeep; Lal, Anupam [Department of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India); Jain, Sanjay [Department of Internal Medicine, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India); Suri, Sudha [Department of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India)

    2011-02-15

    Objective: To analyse the spectrum of Takayasu's arteritis (TA) on multidetector CT angiography (MDCTA). Materials and methods: A retrospective analysis of the MDCTA findings was performed on 15 patients clinically diagnosed as Takayasu's arteritis. The spectrum and incidence of imaging findings on CTA were compared to studies in literature on catheter angiography in Takayasu's arteritis. Laboratory parameters were available in nine patients. The disease was considered active if erythrocyte sedimentation rate (ESR) levels were elevated and 'C' reactive protein (CRP) was positive. An attempt was made to correlate disease activity with the imaging findings. Results: Ascending aorta, arch of aorta and descending thoracic aorta were involved in 14 out of 15 (93%) patients. The wall thickness varied between 1 and 10 mm with maximal involvement in arch and descending thoracic aorta. Major neck vessels were involved in 11 (73%) patients with most pronounced changes seen in the brachiocephalic trunk, left common carotid artery (CCA) and left subclavian artery (SCA). Abdominal aorta and its branches were involved in all the 11 (100%) patients in whom abdominal CTA was performed. Celiac axis and SMA were involved in 10 (91%) and seven (64%) patients, respectively while renal artery stenosis was present in five (45%) patients. In six patients, ESR was elevated and CRP was positive indicating active disease. All patients in whom the laboratory parameters were available showed mural thickening in the aorta and at least one of the neck vessels except for one patient with inactive disease who had aortic mural thickening only. Conclusion: MDCTA provides information about both the vessel wall and lumen in patients with Takayasu's disease.

  16. Multidetector CT: contributions in liver imaging

    Multidetector CT has had great impact in the evaluation of the liver. Increased speed combined with thin slice collimation improved the spatial and temporal resolution, which in turn provided a higher sensitivity in the detection of focal lesions, particularly for the hepatocellular cancer (HCC) in patients with cirrhosis. There is no consensus as to whether the so-called 'double arterial phase scanning' improves the detection rate of hepatocellular cancers, and the majority of the more recent studies suggest acquiring only the late arterial phase images along with the portal venous phase images. However, if the patient is a surgical candidate, the early arterial phase images must also be obtained, because they provide better pre-surgical mapping of the hepatic arteries. In primary and metastatic liver tumors, arterial and portal venous phase images should be acquired with thin collimation and overlapping reconstruction. Maximum intensity projection and volume rendering methods demonstrate the three-dimensional anatomy of the hepatic arteries, portal and hepatic veins successfully, which provide useful information before hepatic resection or intraarterial chemotherapy. In living donor candidates, early arterial and portal venous phase images obtained with thin collimation and overlapping reconstruction are used to reconstruct three-dimensional images with maximum intensity and volume rendering methods. These have a high sensitivity to detect hepatic artery, portal and hepatic vein variations, which could render the surgery difficult or even impossible. Portal venous phase images can also be used to measure total and lobar liver volumes. A virtual hepatectomy plane can be simulated on the three-dimensional model of the liver and hepatic veins, and when necessary, its location can be modified according to the metabolic needs of the recipient and donor. Thin collimation and better temporal resolution may also have beneficial effects in the characterization of liver

  17. Multidetector CT angiography in Takayasu arteritis

    Objective: To analyse the spectrum of Takayasu's arteritis (TA) on multidetector CT angiography (MDCTA). Materials and methods: A retrospective analysis of the MDCTA findings was performed on 15 patients clinically diagnosed as Takayasu's arteritis. The spectrum and incidence of imaging findings on CTA were compared to studies in literature on catheter angiography in Takayasu's arteritis. Laboratory parameters were available in nine patients. The disease was considered active if erythrocyte sedimentation rate (ESR) levels were elevated and 'C' reactive protein (CRP) was positive. An attempt was made to correlate disease activity with the imaging findings. Results: Ascending aorta, arch of aorta and descending thoracic aorta were involved in 14 out of 15 (93%) patients. The wall thickness varied between 1 and 10 mm with maximal involvement in arch and descending thoracic aorta. Major neck vessels were involved in 11 (73%) patients with most pronounced changes seen in the brachiocephalic trunk, left common carotid artery (CCA) and left subclavian artery (SCA). Abdominal aorta and its branches were involved in all the 11 (100%) patients in whom abdominal CTA was performed. Celiac axis and SMA were involved in 10 (91%) and seven (64%) patients, respectively while renal artery stenosis was present in five (45%) patients. In six patients, ESR was elevated and CRP was positive indicating active disease. All patients in whom the laboratory parameters were available showed mural thickening in the aorta and at least one of the neck vessels except for one patient with inactive disease who had aortic mural thickening only. Conclusion: MDCTA provides information about both the vessel wall and lumen in patients with Takayasu's disease.

  18. Importance of multidetector CT imaging in multiple trauma

    Diagnostic imaging of complex multiple trauma remains a challenge for any department providing modern emergency radiology (ER) service. An early and comprehensive approach for ER imaging is crucial for a priority-oriented and timely therapy concept with the aim of identifying potentially life-threatening injuries early and initiating appropriate treatment. The basic diagnostic approach still consists of focused ultrasound using focused assessment with sonography for trauma (FAST) and conventional radiography (CR), usually limited to a single supine chest x-ray for triaging patients undergoing immediate operations. Multidetector computed tomography (MDCT) has become established as early whole body CT (WBCT) as the undisputable diagnostic method. The detection rate of injuries by WBCT is outstanding and it improves the probability of survival by 20-25 % compared with all other previous methods. At the same time, the spatial and temporal resolution of MDCT was improved resulting in considerably shortened examination times but WBCT is still associated with a significant radiation exposure, even in the acute single use setting. Using modern scanner and dose reduction technology, including iterative reconstruction, a dose reduction of up to 40 % could be achieved. The substantial number of images in WBCT is another challenge; images must be processed priority-oriented, read and transferred to the picture archiving and communications system (PACS). For rapid diagnosis, volume image reading (VIR) offers additional options to keep the diagnostic process on time. Modern WBCT after multiple trauma is performed early, comprehensively and personalized so that WBCT improves the probability of survival by 20-25 %. (orig.)

  19. Application of multidetector system in analysis of industrial processes

    Simultaneous application of several scintillation detectors in stimulus response method with radiotracer enable to study flow of material (gas, liquids or solid) in a group of apparatuses or in one apparatus with a complex flow structure. Good acquisition system and proper software for data evaluation and for flow structure modeling is used in the both cases. Several scintillation detectors can be used for valuation of an axial mean velocity profile of solid material in a horizontal rotary kiln. The axial profile of velocity is important technological parameter as the changes of physical and chemical characters of material are cause of the mean velocity changes. The estimation of axial distribution of material in horizontal rotary calcination kiln from production of pigments (TiO2) is presented as an example of utilization of the measured velocity axial profile for obtaining interesting information. Reliable complex flow analysis in one apparatus suppose using collimated scintillation detectors which are situated close to the wall of apparatus. In this case the adequate description of relation between detected values and radiotracer concentration are required. Simple relation was presented for the model of parallel flow and used for flow analysis in Fluidized Catalytic Cracking reactor. Complex flow analysis with multidetector system was also used for verification of numerical results by Computer Fluid Dynamics (CFD) models. The required relation for detection chain was in this case received on the basis of Point Source Response of the detector measured in the system. Special program has been prepared for calculation of detected values of local responses from tracer concentration file received by commercial software for CFD models. The verification of results of CFD model by measurement of RTD and local responses is demonstrated on liquid flow analysis in a pilot plant of heat exchanger

  20. Value of three-dimensional reconstructions in pancreatic carcinoma using multidetector CT: Initial results

    Miriam Klauβ; Max Sch(o)binger; Ivo Wolf; Jens Werner; Hans-Peter Meinzer; Hans-Ulrich Kauczor; Lars Grenacher

    2009-01-01

    AIM: To evaluate the use of three-dimensional imaging of pancreatic carcinoma using multidetector computed tomography (CT) in a prospective study. METHODS: Ten patients with suspected pancreatic tumors were examined prospectively using multidetector CT (Somatom Sensation 16, Siemens, Erlangen, Germany). The images were evaluated for the presence of a pancreatic carcinoma and invasion of the peripancreatic vessels and surrounding organs. Using the isotropic CT data sets, a three-dimensional image was created with automatic vascular analysis and semiautomatic segmentation of the organs and pancreatic tumor by a radiologist. The CT examinations and the three-dimensional images were presented to the surgeon directly before and during the patient's operation using the Medical Imaging Interaction Toolkit-based software "ReLiver". Immediately after surgery, the value of the two images was judged by the surgeon. The operation and the histological results served as the gold standard. RESULTS: Nine patients had a pancreatic carcinoma (all pT3), and one patient had a serous cystadenoma. One tumor infiltrated the superior mesenteric vein. The infiltration was correctly evaluated. All carcinomas were resectable. In comparison to the CT image with axial and coronal reconstructions, the three-dimensional image was judged by the surgeons as better for operation planning and consistently described as useful. CONCLUSION: A 3D-image of the pancreas represents an invaluable aid to the surgeon. However, the 3D-software must be further developed in order to be integrated into daily clinical routine.

  1. Acute colitis: differential diagnosis using multidetector CT

    Aim: To investigate the utility of multidetector CT (MDCT) in helping to establish the underlying cause of acute colitis. Methods and materials: All patients who had acute colitis with a well-identified cause and underwent abdomen 64-MDCT were included in the study. MDCT images were retrospectively analysed in a blinded fashion and the CT findings were correlated with the eventual aetiological diagnosis. Results: The study population included 105 patients. Acute colitis was related to inflammatory bowel disease in 43 cases. MDCT was used to identify six relevant signs of inflammatory colitis: the “comb” sign (p < 0.001), enlarged lymph nodes (p < 0.001), abscess (p = 0.026), fibro-fatty infiltration (p = 0.007), small bowel involvement (p < 0.001), and the absence of an “empty colon” sign (p = 0.045). Multivariate logistic regression analysis identified three independent signs of inflammatory colitis: the “comb” sign, small bowel involvement, and enlarged lymph nodes. Acute colitis was related to bacterial infection in 35 cases. Five signs were significantly associated with infectious colitis: continuous distribution (p = 0.020), an “empty colon” sign (p = 0.002), absence of fat stranding (p = 0.013), and absence of a “comb” sign (p = 0.010) and absence of enlarged lymph nodes (p = 0.035). Multivariate analysis identified three independent signs: the “empty colon” sign and absence of fat stranding and of a “comb” sign. The remaining causes were ischaemic colitis (n = 21) and drug-related colitis (n = 6). MDCT examination provided five relevant signs of ischaemic colitis: fat stranding (p = 0.002), discontinuous distribution (p < 0.001), and absence of enlarged lymph node (p < 0.001), a “comb” sign (p = 0.006) and small bowel involvement (p = 0.037). Conclusions: MDCT provides certain suggestive signs that may be helpful in distinguishing the underlying aetiological cause of acute colitis

  2. Respiratory gated multidetector computed tomography: Applicable for diagnostic abdominal imaging?

    Purpose: To evaluate the ability and accuracy of a respiratory gated technique used with contrast enhanced MDCT of the upper abdomen with focus on diagnostic image quality and depiction of organs and major vessels. Materials and methods: Forty-five adult patients who were referred to our institution for follow-up dynamic contrast enhanced abdominal CT imaging were included in this study. Respiratory gated CT scans were performed with the use of a dedicated hardware. A multiphasic CT scan was performed for each patient. Respiratory gated images were obtained between early arterial and portal venous phases during free breathing. Images of respiratory gated (RG) and breathhold (BH) phases were compared qualitatively and quantitatively by two radiologists. Definitive statistical methods were used for evaluating the scoring data, while Mann Whitney U test was used for comparison. Statistical significance was accepted for p values <0.05. Results: Statistical significant difference was found for comparison of scores regarding luminal opacification and contoural integrity of intrahepatic vascular structures with scores of RG scans rated poor to moderate (e.g. 2.86 ± 1.07 for luminal opacification of intrahepatic portal veins as well as border detectability) in comparison to scores of BH scans rated good to excellent (e.g. 1.37 ± 1.31 for luminal opacification, 1.35 ± 1.28 for border detectability of intrahepatic portal veins, p < 0.001). Furthermore, statistical significant differences were found for general image noise levels (p < 0.001). Conclusions: Further technical advances of RG technique could enable routine use of this technique for selected patient groups.

  3. The relationship between coronary artery calcification detected by non-gated multi-detector CT in patients with suspected ischemic heart disease and myocardial ischemia detected by thallium exercise stress testing

    The objective of this study was to examine whether we could predict myocardial ischemia when coronary artery calcification is detected by non-gated multidetector CT in patients with suspected ischemic heart disease. Eighty-three patients suspected of having ischemic heart disease (55 men, 28 women; age range 36-83 years; mean age 68 years) underwent multidetector CT and Tl-201 single photon emission computed tomography. Prediction of myocardial ischemia by coronary arterial calcification detected on CT was evaluated by comparing the coronary artery territories that showed calcification with the area of myocardial ischemia determined by SPECT. The sensitivity, specificity, positive predictive value, and negative predictive value of multidetector CT for predicting myocardial ischemia were calculated. Coronary angiography was also examined and compared with multidetector CT. Risk factors, including hypertension, smoking, hyperlipidemia, diabetes, and family history, were compared for evidence of coronary artery calcification detected by multidetector CT and myocardial ischemia detected by thallium nuclear scans. For analysis by patients, the sensitivity, specificity, positive predictive value, and negative predictive value of coronary artery calcification for myocardial ischemia detection were 65, 63, 56, and 71%, respectively. Similarly, for analysis by coronary arterial territories, those values were 56, 77, 41 and 86%, respectively. Coronary stenosis on CAG was also related to the ischemia determined by SPECT and calcification on multidetector CT. Ischemia was better influenced by risk factors than was coronary arterial calcification. For analysis by coronary arterial territories, the specificity and negative predictive value of coronary arterial calcification seen by multidetector CT are relatively high. (author)

  4. In vivo location of the vermiform appendix in multidetector CT

    To provide a more detailed classification system regarding the position of the vermiform appendix within the right lower quadrant, as seen on multidetector computed tomography (MDCT) and to investigate the relative differences in frequency of appendiceal position according to patient gender and the pathologic state of appendix. Between January 2008 and December 2010, 1157 patients were included in our final analysis: 542 patients with preoperative MDCT and subsequent appendectomy and 615 patients with visible appendix seen on MDCT performed as part of a health checkup. We classified the appendix according to its position relative to the cecum, the terminal ileum, and the external iliac vessels: type 1: antececal; type 2: preileal; type 3: postileal; type 4: subileal; type 5: subcecal; type 6: deep pelvic; type 7: retrocecal; and type 8: paracecal. The relative incidence of various positions of the appendix found in all of our study patients was: type 1: 3.5%; type 2: 1.7%; type 3: 9.0%; type 4: 12.9%; type 5: 42.3%; type 6: 16.2%; type 7: 10.9%; and type 8: 3.0%. According to patient gender, type 1 (male: 3.7% vs. female: 3.3%), type 3 (8.6% vs. 9.8%), type 4 (14.3% vs. 9.8%), type 5 (47.5% vs. 32.7%), type 7 (9.2% vs. 14.4%), and type 8 (3.4% vs. 2.2%) positions showed a statistically significant male predominance. In terms of the inflamed state, type 2 preileal (normal: 0.8% vs. inflamed: 2.8%), type 3 (10.2% vs. 7.6%), type 4 (14.0% vs. 11.6%), and type 5 (14.1% vs. 18.5%) positions showed a statistically significant difference. Contrary to the common assumption that the retrocecal appendix is the most common position, the in vivo appendix is seen more often on MDCT in the subcecal and deep pelvic positions. The relative frequency of various positions of the appendix can also differ according to patient gender and the pathologic state.

  5. Multidetector row CT study of percutaneous transhepatic intrahepatic portosystemic shunt

    Objective: To investigate imaging features of the liver, portal vein and hepatic vein or transhepatic inferior vena cava in patients with severe liver cirrhosis in multidetector row computed tomography (MDCT), and assess the feasibility, safety and clinical significance of percutaneous transhepatic intrahepatic portosystemic, shunt (PTIPS). Methods: Fifty patients with severe liver cirrhosis confirmed by clinical data and imaging examination were enrolled in this study. Simulation of intrahepatic portosystemic shunt by percutaneous transhepatic, approach is as follows. The right midaxillary line (the eighth oi ninth intercostal space) was selected as puncture point A the right branch of portal vein was puncture point B, transhepatic inferior vena cava was puncture point C, and the distal part of right portal vein was D. A-B-C connection is simulated as percutaneous transhepatic puncture tract, C-B-D connection is simulated as portosystemic shunt tract. After tri-phase contrast-enhanced CT scanning, postprocessing images through multiple planner reconstruction (MPR) were obtained. The data were indicated statistically by x-bar±s. And 9.5% confidence interval for mean was calculated. Anatomic relationship among the right portal vein, transhepatic inferior vena cava, hepatic artery and bile duct were analyzed for all patients. Results: The length of the needle (A-B-C) is (145.7±14.8) mm. The curvature of the needle (the angle of A-B line and B-C line) is (145.0±9.9) . The length of transhepatic shunt tract (B-C) is (42.7±7.2) mm. The length of the shunt tract (C-B-D) is (117.7±11.6) mm; The angle of the shunt tract (the angle of B-C line and B-D line) is (108.5±5.9)°. In 24/50 patients, transhepatic inferior vena cava locate in the dorsal of the right portal vein, in 26/50 patients they are in the same plane. In all patients, the right branches of hepatic artery and bile duct locate in the ventral of the right portal vein. Conclusion: The procedure of PTIPS is

  6. CACTUS - a multidetector set-up at the Oslo Cyclotron

    The design and construction of the multidetector system CACTUS is discussed, and its operation in the context of the Oslo Cyclotron is described. The multidetector system has been initiated to meet the requirements at the Oslo Cyclotron Laboratory in the experimental work on nuclear structure at high intrinsic excitation energy. The laboratory has developed a promising technique based on measuring γ-decay after single nucleon transfer reactions with the use of pγ coincidences. However, a proper interpretation of the experimental results has often been difficult due to low counting rates. One of the most important aims for the new experimental set-up has been to obtain pγ as well as pγγ coincidence spectra with high statistics. The CACTUS detector system which is mounted on the 90o beam line of the cyclotron, consists of 28 NaI and 2 Ge detectors in combination with 8 Si particle telescopes

  7. Congenital heart diseases: post-operative appearance on multi-detector CT - a pictorial essay

    Tomasian, Anderanik; Malik, Sachin; Shamsa, Kamran; Krishnam, Mayil S. [UCLA Medical Center, Department of Radiological Science, Los Angeles, CA (United States)

    2009-12-15

    Echocardiography is considered as an initial imaging modality of choice in patients with congenital heart disease (CHD), and magnetic resonance (MR) imaging is preferred for detailed functional information. Multi-detector computed tomography (CT) plays an important role in clinical practice in assessing post-operative morphological and functional information of patients with complex CHD when echocardiography and MR imaging are not contributory. Radiologists should understand and become familiar with the complex morphology and physiology of CHD, as well as with various palliative and corrective surgical procedures performed in these patients, to obtain CT angiograms with diagnostic quality and promptly recognise imaging features of normal post-operative anatomy and complications of these complex surgeries. (orig.)

  8. Cardiac carcinoid: tricuspid delayed hyperenhancement on cardiac 64-slice multidetector CT and magnetic resonance imaging.

    Martos, R

    2012-02-01

    INTRODUCTION: Carcinoid heart disease is a rare condition in adults. Its diagnosis can be easily missed in a patient presenting to a primary care setting. We revised the advantages of using coronary multidetector computed tomography (MDCT) and cardiac magnetic resonance imaging (MRI) in diagnosing this condition. MATERIALS AND METHODS: We studied a 65-year-old patient with carcinoid heart disease and right heart failure using transthoracic Doppler-echocardiogram, cardiac MDCT and MRI. Cardiac echocardiogram revealed marked thickening and retraction of the tricuspid leaflets with dilated right atrium and ventricle. Cardiac MDCT and MRI demonstrated fixation and retraction of the tricuspid leaflets with delayed contrast hyperenhancement of the tricuspid annulus. CONCLUSION: This case demonstrates fascinating imaging findings of cardiac carcinoid disease and highlights the increasing utility of contrast-enhanced MRI and cardiac MDCT in the diagnosis of this interesting condition.

  9. Congenital heart diseases: post-operative appearance on multi-detector CT - a pictorial essay

    Echocardiography is considered as an initial imaging modality of choice in patients with congenital heart disease (CHD), and magnetic resonance (MR) imaging is preferred for detailed functional information. Multi-detector computed tomography (CT) plays an important role in clinical practice in assessing post-operative morphological and functional information of patients with complex CHD when echocardiography and MR imaging are not contributory. Radiologists should understand and become familiar with the complex morphology and physiology of CHD, as well as with various palliative and corrective surgical procedures performed in these patients, to obtain CT angiograms with diagnostic quality and promptly recognise imaging features of normal post-operative anatomy and complications of these complex surgeries. (orig.)

  10. Multidetector CT and MR Imaging of Cardiac Tumors

    Kim, Eun Young; Choe, Yeon Hyeon; Sung, Kiick; Park, Seung Woo; Kim, Ji Hye; Ko, Young-Hyeh

    2009-01-01

    The purpose of this article is to provide a current review of the spectrum of multidetector CT (MDCT) and MRI findings for a variety of cardiac neoplasms. In the diagnosis of cardiac tumors, the use of MDCT and MRI can help differentiate benign from malignant masses. Especially, the use of MDCT is advantageous in providing anatomical information and MRI is useful for tissue characterization of cardiac masses. Knowledge of the characteristic MRI findings of benign cardiac tumors or thrombi can...

  11. Controversies in imaging of hepatocellular carcinoma: multidetector CT (MDCT)

    Silverman, Paul M.; Szklaruk, Janio

    2005-01-01

    Primary hepatocellular carcinoma (HCC) is a significant tumor worldwide and represents the most common primary hepatic neoplasm. Staging criteria are important for appreciation of timely work up of these neoplasms in contradiction with surgical colleagues. This article demonstrates the appearance of HCC on multiphasic, multidetector CT (MDCT) and relates these findings to current staging criteria. The variable appearance on different planes of contrast is critical to appreciate in staging thi...

  12. Multi-detector CT knee arthrography - initial experience

    Full text: Traditional plain film arthrography can achieve reasonable accuracy and is an accepted method of investigation of patients with knee pain and possible meniscal tear. Multi-detector CT can potentially provide a more detailed and accurate examination due to its high-resolution crosssectional and multi-planar capabilities. The aim of this study was to assess the accuracy of our technique. All patients who underwent a multi-detector CT knee arthrogram in an initial 8 month period were identified. Initially the referring clinician was contacted. If the patient was referred to an orthopaedic surgeon the outcome of orthopaedic review was recorded using clinical, arthroscopic and / or MRI follow-up of the patient population. One hundred and twelve patients had a Multi-detector CT knee arthrogram performed within and 8 month period. Follow-up information was received in 69.7% of patients. Of these 68.9% had orthopaedic assessment - of which 69.2% underwent a knee arthroscopy.There was total agreement of findings in 67%, agreement of meniscal findings in 67% and chondral findings in 100%. Overall, orthopaedic opinion agreed with CT findings in 76.9%. At this stage, all meniscal tears not described in the initial CT arthrogram report have in retrospect been visible. Multi-detector CT knee arthrography is an accurate and elegant technique for investigation of knee pain, providing information in a format familiar to those reporting knee MRI. There is an initial learning curve. The technique is particularly useful in chondral assessment. It is accurate for meniscal pathology, although caution and recognition of potential pitfalls is required. Copyright (2002) Blackwell Science Pty Ltd

  13. An F-statistic based multi-detector veto for detector artifacts in continuous-wave gravitational wave data

    Keitel, D.; Prix, R.; Papa, M.; Siddiqi, M.

    2012-01-01

    Continuous gravitational waves (CW) are expected from spinning neutron stars with non-axisymmetric deformations. A network of interferometric detectors (LIGO, Virgo and GEO600) is looking for these signals. They are predicted to be very weak and retrievable only by integration over long observation times. One of the standard methods of CW data analysis is the multi-detector F-statistic. In a typical search, the F-statistic is computed over a range in frequency, spin-down and sky position, and...

  14. Multidetector CT imaging of mechanical prosthetic heart valves: quantification of artifacts with a pulsatile in-vitro model

    Symersky, P.; Budde, R. P. J.; Westers, P.; Mol, de, B.A.J.M.; Prokop, M

    2011-01-01

    Objectives Multidetector computed tomography (MDCT) can detect the cause of prosthetic heart valve (PHV) dysfunction but is hampered by valve-induced artifacts. We quantified artifacts of four PHV using a pulsatile in-vitro model and assessed the relation to leaflet motion and valve design. Methods A Medtronic Hall tilting disc (MH), and Carbomedics (CM), St Jude (SJM), and ON-X bileaflet valves underwent CT in an in-vitro model using retrospective gating with a 64 detector CT system in stati...

  15. Study of Coronary Arteries by Means of Multidetector CT; Estudio de las arterias coronarias mediante tomografia computarizada multidetector

    Fernandez, G. C.; Costas, M. I.; Delgado, C.; Velasco, M.; Tardaguila, F. [Hospital POVISA. Vigo. Pontevedra (Spain)

    2004-07-01

    Radiological study of coronary arteries has undergone major advances,especially with the incorporation of new CT multidetectors which afford temporary spatial resolution sufficient for the acquisition of high-quality images and diagnoses concerning various coronary artery abnormalities. The technique is described in terms of both facilitating data within a procedure making use of beta-blockers to slow heart rate and postprocess image reconstruction. Accordingly, our experience with a 16-detector CT and its clinical applications are illustrated. (Author)

  16. Scenes from the past: multidetector CT of Egyptian mummies of the Redpath Museum.

    Wade, Andrew D; Garvin, Gregory J; Hurnanen, Jaana H; Williams, Licd Lana; Lawson, Barbara; Nelson, Andrew J; Tampieri, Donatella

    2012-01-01

    As a nondestructive method of historical and anthropologic inquiry, imaging has played an important role in mummy studies over the past several decades. Recent technologic advances have made multidetector computed tomography (CT) an especially useful means for deepening the present understanding of ancient cultures by examining preserved human remains. In April 2011, three ancient Egyptian human mummies from the Redpath Museum of McGill University were examined with 320-section multidetector CT as part of the IMPACT Radiological Mummy Database project headquartered at the University of Western Ontario. Whole-body scanning was performed with a section thickness of 0.5 mm and a peak voltage of 120 kVp, and the raw CT datasets were postprocessed by using smooth body and high-resolution bone convolution filters. Two of the mummies were scanned at different energy levels (80 and 135 keV). The high-resolution CT scans revealed the details of mummification and allowed observations about the socioeconomic and health status of the human subjects based on both the mummification technique used and the appearance of the remains, particularly the bones and teeth. The paleopathologic information obtained from the scans confirmed some findings in studies performed in the same mummies in the late 19th and 20th centuries. The CT scans also demonstrated a high degree of variability in Egyptian mortuary practice, variability that is not generally recognized in the literature. Unusual features that were observed included a relatively uncommon retained heart in mummy RM2718, retained lungs in a mummy from which the heart had been extracted (RM2720), and a cartonnage plaque placed over the left abdomen of a mummy that had been eviscerated transperineally (RM2717). PMID:22787004

  17. Multidetector CT in evaluating blood supply of hepatocellular carcinoma after transcatheter arterial chemoembolization

    Yong-Song Guan; Xiao-Hua Zheng; Xiang-Ping Zhou; Juan Huang; Long Sun; Xian Chen; Xiao Li; Qing He

    2004-01-01

    AIM: To assess the value of multidetector-row computed tomography (MDCT) in choosing retreatment methods of hepatocellular carcinoma (HCC) through evaluating the blood supply of low-density area of HCC after transcatheter arterial chemoembolization (TACE).METHODS: Thirty-two patients with HCC after TACE treatment were examined by plain scanning and hepatic multidetector-row CT. The location of low-density area on plain scanning and the enhancement patterns on dynamic contrast-enhanced scanning were observed. At the same time, three-dimensional CT (3D CT) models of the volume rendering, curved multiplanar reformations, surface shaded display and maximum intensity projection reconstruction of the hepatic artery and portal vein were performed in 6 cases.RESULTS: In CT plain scanning data, low density areas of 32 cases of HCC after TACE treatment were divided into three types: peripheral, one-side-located and mixed types.In contrast-enhanced CT scans, the blood supply of lowdensity area was classified into four types: arterial blood supply (20 cases), portal blood supply (5 cases), arterial combined with portal blood supply (5 cases) and poor blood supply (2 cases). In 6 cases, the relationship between the low-density area and branches of hepatic artery as well as portal vein was shown by 3D CT.CONCLUSION: Hepatic MDCT is an effective method for evaluating the blood supply of low-density area and therapeutic effect of HCC after TACE treatment. Types of blood supply is helpful for the selection of retreatment.

  18. Adult Moyamoya disease: 320-Multidetector row CT for evaluation of revascularization in STA–MCA bypasses surgery

    Purpose: To evaluate the utility of 320-multidetector row whole-brain computed tomography perfusion (WBCTP) and whole-head subtracted dynamic angiography (WHSDCTA) for assessing the revascularization of blood flow after superficial temporal artery (STA) to middle cerebral artery (MCA) bypass surgery in adults with Moyamoya disease (MD) in the short and long term. Patients and methods: 320-multidetector row WBCTP and WHSDCTA were applied in 20 patients with MD before and after surgery (for an average of 3 days and 3 months). The bypass arteries were investigated using WHSDCTA and compared with DSA. The regions of interests (ROIs) in the surgical and mirror sides of the cerebral cortex were drawn on a Vitrea Workstation. Cerebral blood volume (CBV), time to peak (TTP), cerebral blood flow (CBF), mean transit time (MTT), and delay time were recorded. Preoperative and postoperative perfusion parameters in the MCA distribution were compared using the paired t-test. Results: WHSDCTA could clearly demonstrate 24 bypass arteries in 26 arteries for 20 patients, results which were in accordance with the results of digital subtraction angiography (DSA). When comparing preoperative values to those within 3 days after surgery, only TTP and delay time were significantly different (P < 0.05). Values of CBV, TTP, CBF, delay time, and MTT 3 months after surgery were significantly different (P < 0.05) from those of preoperative perfusion. Conclusion: These data suggest that 320-multidetector row WBCTP and WHSDCTA can be used to evaluate the revascularization of blood flow after STA–MCA bypass surgery in patients with MD in the short and long term

  19. Adult Moyamoya disease: 320-Multidetector row CT for evaluation of revascularization in STA–MCA bypasses surgery

    Tian, Bing; Xu, Bing; Liu, Qi; Hao, Qiang; Lu, Jianping, E-mail: cjr.lujianping@vip.163.com

    2013-12-01

    Purpose: To evaluate the utility of 320-multidetector row whole-brain computed tomography perfusion (WBCTP) and whole-head subtracted dynamic angiography (WHSDCTA) for assessing the revascularization of blood flow after superficial temporal artery (STA) to middle cerebral artery (MCA) bypass surgery in adults with Moyamoya disease (MD) in the short and long term. Patients and methods: 320-multidetector row WBCTP and WHSDCTA were applied in 20 patients with MD before and after surgery (for an average of 3 days and 3 months). The bypass arteries were investigated using WHSDCTA and compared with DSA. The regions of interests (ROIs) in the surgical and mirror sides of the cerebral cortex were drawn on a Vitrea Workstation. Cerebral blood volume (CBV), time to peak (TTP), cerebral blood flow (CBF), mean transit time (MTT), and delay time were recorded. Preoperative and postoperative perfusion parameters in the MCA distribution were compared using the paired t-test. Results: WHSDCTA could clearly demonstrate 24 bypass arteries in 26 arteries for 20 patients, results which were in accordance with the results of digital subtraction angiography (DSA). When comparing preoperative values to those within 3 days after surgery, only TTP and delay time were significantly different (P < 0.05). Values of CBV, TTP, CBF, delay time, and MTT 3 months after surgery were significantly different (P < 0.05) from those of preoperative perfusion. Conclusion: These data suggest that 320-multidetector row WBCTP and WHSDCTA can be used to evaluate the revascularization of blood flow after STA–MCA bypass surgery in patients with MD in the short and long term.

  20. Quantitative Features of Liver Lesions, Lung Nodules, and Renal Stones at Multi-Detector Row CT Examinations: Dependency on Radiation Dose and Reconstruction Algorithm.

    Solomon, Justin; Mileto, Achille; Nelson, Rendon C; Roy Choudhury, Kingshuk; Samei, Ehsan

    2016-04-01

    Purpose To determine if radiation dose and reconstruction algorithm affect the computer-based extraction and analysis of quantitative imaging features in lung nodules, liver lesions, and renal stones at multi-detector row computed tomography (CT). Materials and Methods Retrospective analysis of data from a prospective, multicenter, HIPAA-compliant, institutional review board-approved clinical trial was performed by extracting 23 quantitative imaging features (size, shape, attenuation, edge sharpness, pixel value distribution, and texture) of lesions on multi-detector row CT images of 20 adult patients (14 men, six women; mean age, 63 years; range, 38-72 years) referred for known or suspected focal liver lesions, lung nodules, or kidney stones. Data were acquired between September 2011 and April 2012. All multi-detector row CT scans were performed at two different radiation dose levels; images were reconstructed with filtered back projection, adaptive statistical iterative reconstruction, and model-based iterative reconstruction (MBIR) algorithms. A linear mixed-effects model was used to assess the effect of radiation dose and reconstruction algorithm on extracted features. Results Among the 23 imaging features assessed, radiation dose had a significant effect on five, three, and four of the features for liver lesions, lung nodules, and renal stones, respectively (P stones, respectively (P stones, respectively (P stones with MBIR was significantly different than those for the other two algorithms (P < .002 for all comparisons). Although lesion texture was significantly affected by the reconstruction algorithm used (average of 3.33 features affected by MBIR throughout lesion types; P < .002, for all comparisons), no significant effect of the radiation dose setting was observed for all but one of the texture features (P = .002-.998). Conclusion Radiation dose settings and reconstruction algorithms affect the extraction and analysis of quantitative imaging features in

  1. Value of Virtual Colonoscopy with 64 Row CT in Evaluation of Colorectal Cancer

    Virtual colonoscopy (VC) enables three-dimensional view of walls and internal lumen of the colon as a result of reconstruction of multislice CT images. The role of VC in diagnosis of the colon abnormalities systematically increases, and in many medical centers all over the world is carried out as a screening test of patients with high risk of colorectal cancer. We analyzed results of virtual colonoscopy of 360 patients with clinical suspicion of colorectal cancer. Sensitivity and specificity of CT colonoscopy for detection of colon cancers and polyps were assessed. Results of our research have shown high diagnostic efficiency of CT colonoscopy in detection of focal lesions in large intestine of 10 mm or more diameter. Sensitivity was 85.7%, specificity 89.2%. Virtual colonoscopy is noninvasive and well tolerated by patients imaging method, which permits for early detection of the large intestine lesions with specificity and sensitivity similar to classical colonoscopy in screening exams in patients suspected for colorectal cancer. Good preparation of the patients for the examination is very important for proper diagnosis and interpretation of this imaginge procedure

  2. EUROGAM, a new gamma multidetector array: results and perspectives

    The new γ multidetector EUROGAM has been developed and built by a France - United Kingdom collaboration. Many experiments have performed with EUROGAM phase 1 at the Nuclear Structure Facility at Daresbury (U.K.) and recently with the phase 2 at the Vivitron at Strasbourg (France). Some of the most outstanding results concerning the superdeformation phenomenon and the oblate dipole bands will be discussed. GA.SP (Italy) and EUROGAM constitute the two first phases of the European Project EUROBALL. (author). 25 refs., 13 figs

  3. Neutron multi-detector system: mutual influence of its modules

    A position-sensitive neutron detector (PSND) has been designed and tested as a module of a multi-detector array. ''Cross-talk'' effects, contributing a major distortion factor for all closely packed neutron detector systems, have been measured. It was established, using neutrons from the spontaneous fission of 252Cf (setting neutron energy threshold at 0.7 MeV), that the distortions of neutron energy and of neutron angular distribution are insignificant (within the level of statistical accuracy). The influence of cross-talk on the coincidence counting rate was measured to range from 48% to 16% for distances between detector's axes of 12 to 24 cm. ((orig.))

  4. Pneumomediastinum on Multidetector CT: The Radiologic Signs and Underlying Disorders

    Oh, Soo Jin; Kim, Young Tong [Soonchunhyang University Chunan Hospital, Cheonan (Korea, Republic of)

    2011-02-15

    We can see the typical signs of pneumomediastinum on chest radiography and we can also see them on the multiplanar reformatted (MPR) image of multidetector CT (MDCT). MDCT can help to understand the anatomical feature of these signs and differentiate pneumomediastinum from pneumothorax, pneumopericardium and the Mach band effect. MDCT shows the peribronchovascular air, which reveals the Macklin effect, and it can also evaluate the underlying disorders that cause pneumomediastinum. The purpose of this pictorial essay is to inform physicians about the mechanism and anatomical features of pneumomediastinum, and to help them understand the imaging findings and underlying disorders of pneumomediastinum as seen on MDCT

  5. Radiological emergency room management with emphasis on multidetector-row

    Trauma is the fifth leading cause of death after disease of the cardiovascular system, malignomas and disease of the respiratory and digestive system. The management of severely injured patients, including radiological imaging, is a matter of ongoing development. In particular, as for the imaging modalities, multidetector-row CT represents a substantial refinement in the diagnostic work-up of multitrauma patients. Sufficient therapy within the first hour after trauma increases the patient's chances for survival significantly. Thus, therapeutic procedures and diagnostic evaluation have to be concomitant events, performed by a multidisciplinary team, namely trauma surgeon, anesthesiologist and, last but not least, radiologist. The increased performance of multidetector-row CT leads to increased spatial resolution, which is a prerequisite for sophisticated two- and three-dimensional postprocessing. The increased volume coverage speed allows for comprehensive whole-body CT at still high levels of spatial resolution, resulting in significant spare of time which influences patient's survival. Using this technique conventional imaging such as plane film or angiography may be omitted

  6. Radiological emergency room management with emphasis on multidetector-row

    Philipp, M.O.; Kubin, K.; Hoermann, M.; Metz, V.M. E-mail: viktor.metz@univie.ac.at

    2003-10-01

    Trauma is the fifth leading cause of death after disease of the cardiovascular system, malignomas and disease of the respiratory and digestive system. The management of severely injured patients, including radiological imaging, is a matter of ongoing development. In particular, as for the imaging modalities, multidetector-row CT represents a substantial refinement in the diagnostic work-up of multitrauma patients. Sufficient therapy within the first hour after trauma increases the patient's chances for survival significantly. Thus, therapeutic procedures and diagnostic evaluation have to be concomitant events, performed by a multidisciplinary team, namely trauma surgeon, anesthesiologist and, last but not least, radiologist. The increased performance of multidetector-row CT leads to increased spatial resolution, which is a prerequisite for sophisticated two- and three-dimensional postprocessing. The increased volume coverage speed allows for comprehensive whole-body CT at still high levels of spatial resolution, resulting in significant spare of time which influences patient's survival. Using this technique conventional imaging such as plane film or angiography may be omitted.

  7. Certeza diagnóstica de la tomografía computarizada multicorte para la detección de la vasculopatía del injerto cardiaco: comparación con angiografía coronaria invasiva y ecografía intravascular Accuracy of multidetector row computed tomography for the detection of transplant vasculopathy: comparison with invasive coronary angiography and intravascular ultrasound

    Patricia Carrascosa

    2009-06-01

    Full Text Available Objetivo: Evaluar la certeza diagnóstica de la tomografía computarizada multicorte (TCM en pacientes trasplantados cardiacos para la detección de estenosis coronaria y vasculopatía del injerto cardiaco (VDI en comparación con la angiografía coronaria (AC y la ecografía intravascular (EIV, respectivamente. Material y métodos: Diecinueve pacientes trasplantados cardiacos fueron estudiados con angiografía coronaria por TCM entre 7 a 14 días después del cateterismo (AD y EIV. Los estudios se llevaron a cabo con un tomógrafo multicorte de 16 filas. Dos observadores evaluaron en forma ciega los estudios de TCM para la detección de estenosis coronaria >50% y VDI. Resultados: Para la detección de estenosis coronaria >50%, la sensibilidad fue: 80-88% y la especificidad: 98- 99%; para la detección de VDI, 91-96% y 88-98%, respectivamente. Conclusión: En esta serie preliminar, nuestros resultados mostraron que la TCM fue una técnica adecuada para evaluar pacientes trasplantados cardiacos y podría ser una alternativa a la AD y EIV para el seguimiento y control no invasivo de estos pacientes.Objective: To evaluate the diagnostic accuracy of multidetector computed tomography (MDCT for detection of luminal stenosis and cardiac allograft vasculopathy in comparison with coronary angiography (CA and intravascular ultrasound (IVUS respectively. Material and methods: Nineteen cardiac transplant patients scheduled for follow-up CA were included. MDCT coronary angiography was performed using a 16-row CT scanner within 7-14 days after CA and IVUS. Studies were analyzed by independent readers; two observers evaluated the CT datasets for the presence of coronary artery stenosis >50% and allograft vasculopathy. Results: The sensitivity for detecting >50% luminal stenosis was 80-88% and specificity, 98-99% and for detection of cardiac allograft vasculopathy, the sensitivity was 91-96% and specificity, 88-91%. Conclusion: In this preliminary series, our

  8. Influence of z overscanning on normalized effective doses calculated for pediatric patients undergoing multidetector CT examinations

    The purpose of this study was to evaluate the effect of z overscanning on normalized effective dose for pediatric patients undergoing multidetector-computed tomography (CT) examinations. Five commercially available mathematical anthropomorphic phantoms representing newborn, 1-, 5-, 10-, and 15-year-old patients and the Monte Carlo N-Particle (MCNP, version 4C2) radiation transport code were employed in the current study to simulate pediatric CT exposures. For all phantoms, axial and helical examinations at 120 kV tube voltage were simulated. Scans performed at 80 kV were also simulated. Sex-specific normalized effective doses were estimated for four standard CT examinations i.e., head-neck, chest, abdomen-pelvis, and trunk, for all pediatric phantoms. Data for both axial and helical mode acquisition were obtained. In the helical mode, z overscanning was taken into account. The validity of the Monte Carlo results was verified by comparison with dose data obtained using thermoluminescence dosimetry and a physical pediatric anthropomorphic phantom simulating a 10-year-old child. In all cases normalized effective dose values were found to increase with increasing z overscanning. The percentage differences in normalized data between axial and helical scans may reach 43%, 70%, 36%, and 26% for head-neck, chest, abdomen-pelvis, and trunk studies, respectively. Normalized data for female pediatric patients was in general higher compared to male patients for all ages, examined regions, and z overscanning values. For both male and female children, the normalized effective dose values were reduced as the age was increased. For the same typical exposure conditions, dose values decreased when lower tube voltage was used; for a 1-year-old child, for example, the effective dose was 3.8 times lower when 80 kV instead of 120 kV was used. Normalized data for the estimation of effective dose to pediatric patients undergoing standard axial and helical CT examinations on an

  9. Accuracy of the CT numbers of simulated lung nodules imaged with multi-detector CT scanners

    retrospectively from the multi-detector helical CT projection data of the standard NLST protocol yield CT numbers for the 4.8 mm diameter nodules that are more accurate and reproducible than those of the standard NLST technique. In general, the CT numbers of the nodules were found to be lower at positions near the centers of the lungs and near the spine, which is probably due to increased beam hardening in those regions. Also, larger nodules were found to have higher CT numbers than smaller nodules, consistent with results obtained on early single slice GE CT scanners. Until manufacturers develop quantitative CT scanners with improved x-ray beam hardening and scatter corrections, it is recommended that reference phantoms be employed to more accurately assess the calcium contents of patient lung nodules in screening and tissue characterization studies and in eventual computer-aided detection and diagnosis applications

  10. Assessment of extracranial-intracranial bypass patency with 64-slice multidetector computerized tomography angiography

    Extracranial-intracranial (EC/IC) bypass is a useful procedure for the treatment of cerebral vascular insufficiency or complex aneurysms. We explored the role of multidetector computed tomography angiography (MDCTA), instead of digital subtraction angiography (DSA), for the postoperative assessment of EC/IC bypass patency. We retrospectively analyzed a consecutive series of 21 MDCTAs from 17 patients that underwent 25 direct or indirect EC/IC bypass procedures between April 2003 and November 2007. Conventional DSA was available for comparison in 13 cases. MDCTA used a 64-slice MDCT scanner (Aquilion 64, Toshiba). The proximal and distal patencies were analyzed independently on MDCTA and DSA by a neuroradiologist and a neurosurgeon. The bypass was considered patent when the entire donor vessel was opacified without discontinuity from proximal to distal ends and was visibly in contact with the recipient vessel. MDCTA depicted the patency status in every patient. Bypasses were patent in 22 cases, stenosed in one, and occluded in two. DSA always confirmed the results of the MDCTA (sensitivity = 100%, 95% CI = 0.655-1.0; specificity 100%, 95% CI = 0.05-1.0). MDCTA is a non-invasive and accurate exam to assess the postoperative EC/IC bypass patency and is a promising technique in routine follow-up. (orig.)

  11. Optimised low-dose multidetector CT protocol for children with cranial deformity

    Vazquez, Jose Luis [Complejo Hospitalario Universitario de Vigo, Department of Radiology, Vigo, Pontevedra (Spain); Pombar, Miguel Angel [Complejo Hospitalario Universitario de Santiago, Department of Radiophysics, Santiago de Compostela, La Coruna (Spain); Pumar, Jose Manuel [Complejo Hospitalario Universitario de Santiago, Department of Radiology, Santiago de Compostela, La Coruna (Spain); Campo, Victor Miguel del [Complejo Hospitalario Universitario de Vigo, Department of Public Health, Vigo, Pontevedra (Spain)

    2013-08-15

    To present an optimised low-dose multidetector computed tomography (MDCT) protocol for the study of children with cranial deformity. Ninety-one consecutive MDCT studies were performed in 80 children. Studies were performed with either our standard head CT protocol (group 1, n = 20) or a low-dose cranial deformity protocol (groups 2 and 3). Group 2 (n = 38), initial, and group 3 (n = 33), final and more optimised. All studies were performed in the same 64-MDCT equipment. Cranial deformity protocol was gradationally optimised decreasing kVp, limiting mA range, using automatic exposure control (AEC) and increasing the noise index (NI). Image quality was assessed. Dose indicators such us CT dose index volume (CTDIvol), dose-length product (DLP) and effective dose (E) were used. The optimised low-dose protocol reached the following values: 80 kVp, mA range: 50-150 and NI = 23. We achieved a maximum dose reduction of 10-22 times in the 1- to 12-month-old cranium in regard to the 2004 European guidelines for MDCT. A low-dose MDCT protocol that may be used as the first diagnostic imaging option in clinically selected patients with skull abnormalities. (orig.)

  12. Accuracy of multidetector-row CT in diagnosing lymph node metastasis in patients with gastric cancer

    The purpose of this study was to determine the optimal cut-off value of lymph node size for diagnosing metastasis in gastric cancer with multidetector-row computed tomography (MDCT) after categorizing perigastric lymph nodes into three regions. The study included 90 gastric cancer patients who underwent gastrectomy. The long-axis diameter (LAD) and short-axis diameter (SAD) of all visualized lymph nodes were measured with transverse MDCT images. The locations of lymph nodes were categorized into three regions: lesser curvature, greater curvature, and suprapancreatic. The diagnostic value of lymph node metastasis was assessed with receiver operating characteristic (ROC) analysis. The area under the curve was larger for SAD than LAD in all groups. The optimal cut-off values of SAD were determined as follows: overall, 9 mm; differentiated type, 9 mm; undifferentiated type, 8 mm; lesser curvature region, 7 mm; greater curvature region, 6 mm; and suprapancreatic region, 9 mm. The diagnostic accuracies for lymph node metastasis using individual cut-off values were 71.1 % based on histological type and 76.6 % based on region of lymph node location. The diagnostic accuracy of lymph node metastasis in gastric cancer was improved by using individual cut-off values for each lymph node region. (orig.)

  13. A comparative review of multidetector CT angiography and MRI in the diagnosis of jugular foramen lesions

    Christie, A., E-mail: andychristie90@hotmail.co [Radiology Department, Institute of Neurosciences, Glasgow, Scotland (United Kingdom); Teasdale, E. [Radiology Department, Institute of Neurosciences, Glasgow, Scotland (United Kingdom)

    2010-03-15

    Aim: To compare the efficiency of multidetector computed tomography (MDCT) and magnetic resonance imaging (MRI) in the diagnosis of jugular foramen lesions. Materials and methods: The imaging of 15 patients with tumours predominantly occurring at the jugular foramen was retrospectively reviewed, with postoperative pathology data available for 11 patients. MDCT was performed at arterial phase and MRI with standard sequences and contrast enhancement. All imaging was blindly re-reported by an experienced neuroradiologist. Results: Pathology reported six glomus jugulare tumours and five neuromas, which were all correctly diagnosed using MDCT. A confident diagnosis was also made in the remaining four cases based on the pattern of enhancement. Only glomus tumours enhanced in the arterial phase. Overall, MRI was used to make a confident diagnosis in eight patients. One showed no enhancement and was correctly diagnosed as a neuroma, and seven demonstrated the tumour flow voids characteristic of a glomus tumour. The remaining seven cases all showed a similar enhancement pattern and could not be confidently differentiated between a neuroma or a glomus tumour. MDCT angiography enabled a confident assessment of the jugular vein in all cases, but MRI was inconclusive in a third of cases. Also, in the nine cases of glomus tumour diagnosed using MDCT, an enlarged feeding artery was identified in eight patients. Conclusion: MDCT is more accurate than MRI in diagnosing glomus tumours, and in particular, neuromas. It also offers valuable preoperative vascular information to the surgeon.

  14. Contrast enhanced multi-detector CT and MR findings of a well-differentiated pancreatic vipoma

    Luigi; Camera; Rosa; Severino; Antongiulio; Faggiano; Stefania; Masone; Gelsomina; Mansueto; Simone; Maurea; Rosa; Fonti; Marco; Salvatore

    2014-01-01

    Pancreatic vipoma is an extremely rare tumor accounting for less than 2% of endocrine pancreatic neoplasms with a reported incidence of 0.1-0.6 per million. While cross-sectional imaging findings are usually not specific, exact localization of the tumor by means of either computed tomography(CT) or magnetic resonance(MR) is pivotal for surgical planning. However, cross-sectional imaging findings are usually not specific and further characterization of the tumor may only be achieved bysomatostatin-receptor scintigraphy(SRS). We report the case of a 70 years old female with a two years history of watery diarrhoea who was found to have a solid, inhomogeneously enhancing lesion at the level of the pancreatic tail at Gadolinium-enhanced MR(Somatom Trio 3T, Siemens, Germany). The tumor had been prospectively overlooked at a contrast-enhanced multi-detector CT(Aquilion 64, Toshiba, Japan) performed after i.v. bolus injection of only 100 cc of iodinated non ionic contrast media because of a chronic renal failure(3.4 mg/mL) but it was subsequently confirmed by SRS. The patient first underwent a successful symptomatic treatment with somatostatin analogues and was then submitted to a distal pancreasectomy with splenectomy to remove a capsulated whitish tumor which turned out to be a well-differentiated vipoma at histological and immuno-histochemical analysis.

  15. Contrast enhancement pattern on multidetector CT predicts malignancy in pancreatic endocrine tumours

    Preoperative suspicion of malignancy in pancreatic neuroendocrine tumours (pNETs) is mostly based on tumour size. We retrospectively reviewed the contrast enhancement pattern (CEP) of a series of pNETs on multiphasic multidetector computed tomography (MDCT), to identify further imaging features predictive of lesion aggressiveness. Sixty pNETs, diagnosed in 52 patients, were classified based on CEP as: type A showing early contrast enhancement and rapid wash-out; type B presenting even (B1) or only (B2) late enhancement. All tumours were resected allowing pathologic correlations. Nineteen pNETs showed type A CEP (5-20 mm), 29 type B1 CEP (5-80 mm) and 12 type B2 (15-100 mm). All tumours were classified as well differentiated tumours, 19 were benign (WDt-b), 15 with uncertain behaviour (WDt-u) and 26 carcinomas (WDC). None of A lesions were malignant (12 WDt-b; 7 WDt-u), all B2 lesions were WDC, 7 B1 lesions were WDt-b, 8 WDt-u and 14 WDC; 4/34 (12 %) lesions ≤2cm were WDC. CEP showed correlation with all histological prognostic indicators. Correlating with the lesion grading and other histological prognostic predictors, CEP may preoperatively suggest the behaviour of pNETs, assisting decisions about treatment. Moreover CEP allows recognition of malignant small tumours, incorrectly classified on the basis of their dimension. (orig.)

  16. Contrast enhancement pattern on multidetector CT predicts malignancy in pancreatic endocrine tumours

    Cappelli, Carla [University of Pisa, Diagnostic and Interventional Radiology, Department of Translational Research and New Technologies in Medicine and Surgery, Pisa (Italy); Azienda Ospedaliero-Universitaria Pisana-Radiodiagnostica I, Pisa (Italy); Boggi, Ugo [University of Pisa, General and Transplant Surgery, Department of Translational Research and New Technologies in Medicine and Surgery, Pisa (Italy); Mazzeo, Salvatore; Cervelli, Rosa; Contillo, Benedetta Pontillo; Bartolozzi, Carlo [University of Pisa, Diagnostic and Interventional Radiology, Department of Translational Research and New Technologies in Medicine and Surgery, Pisa (Italy); Campani, Daniela; Funel, Niccola [University of Pisa, Pathology, Department of Surgical, Medical, Molecular and Critical Area Pathology, Pisa (Italy)

    2014-12-02

    Preoperative suspicion of malignancy in pancreatic neuroendocrine tumours (pNETs) is mostly based on tumour size. We retrospectively reviewed the contrast enhancement pattern (CEP) of a series of pNETs on multiphasic multidetector computed tomography (MDCT), to identify further imaging features predictive of lesion aggressiveness. Sixty pNETs, diagnosed in 52 patients, were classified based on CEP as: type A showing early contrast enhancement and rapid wash-out; type B presenting even (B1) or only (B2) late enhancement. All tumours were resected allowing pathologic correlations. Nineteen pNETs showed type A CEP (5-20 mm), 29 type B1 CEP (5-80 mm) and 12 type B2 (15-100 mm). All tumours were classified as well differentiated tumours, 19 were benign (WDt-b), 15 with uncertain behaviour (WDt-u) and 26 carcinomas (WDC). None of A lesions were malignant (12 WDt-b; 7 WDt-u), all B2 lesions were WDC, 7 B1 lesions were WDt-b, 8 WDt-u and 14 WDC; 4/34 (12 %) lesions ≤2cm were WDC. CEP showed correlation with all histological prognostic indicators. Correlating with the lesion grading and other histological prognostic predictors, CEP may preoperatively suggest the behaviour of pNETs, assisting decisions about treatment. Moreover CEP allows recognition of malignant small tumours, incorrectly classified on the basis of their dimension. (orig.)

  17. Accuracy of multidetector-row CT in diagnosing lymph node metastasis in patients with gastric cancer

    Saito, Takuro; Kurokawa, Yukinori; Takiguchi, Shuji; Miyazaki, Yasuhiro; Takahashi, Tsuyoshi; Yamasaki, Makoto; Miyata, Hiroshi; Nakajima, Kiyokazu; Mori, Masaki; Doki, Yuichiro [Osaka University, Graduate School of Medicine, Department of Gastroenterological Surgery, Suita, Osaka (Japan)

    2014-08-06

    The purpose of this study was to determine the optimal cut-off value of lymph node size for diagnosing metastasis in gastric cancer with multidetector-row computed tomography (MDCT) after categorizing perigastric lymph nodes into three regions. The study included 90 gastric cancer patients who underwent gastrectomy. The long-axis diameter (LAD) and short-axis diameter (SAD) of all visualized lymph nodes were measured with transverse MDCT images. The locations of lymph nodes were categorized into three regions: lesser curvature, greater curvature, and suprapancreatic. The diagnostic value of lymph node metastasis was assessed with receiver operating characteristic (ROC) analysis. The area under the curve was larger for SAD than LAD in all groups. The optimal cut-off values of SAD were determined as follows: overall, 9 mm; differentiated type, 9 mm; undifferentiated type, 8 mm; lesser curvature region, 7 mm; greater curvature region, 6 mm; and suprapancreatic region, 9 mm. The diagnostic accuracies for lymph node metastasis using individual cut-off values were 71.1 % based on histological type and 76.6 % based on region of lymph node location. The diagnostic accuracy of lymph node metastasis in gastric cancer was improved by using individual cut-off values for each lymph node region. (orig.)

  18. Detection, visualization and evaluation of anomalous coronary anatomy on 16-slice multidetector-row CT

    Early identification and evaluation of relatively frequent anomalous coronary anatomy is quite relevant because of the occurrence of sudden cardiac death or related symptoms of myocardial ischemia. Selective coronary angiography (CAG) is invasive, expensive and cannot always provide the required information adequately. Recently, non-invasive imaging techniques such as magnetic resonance imaging and multidetector-row computed tomography (MDCT) have been shown to provide a good anatomical view of the coronary artery tree. This study aims to demonstrate the value of 16-MDCT for evaluation of anomalous coronary anatomy. In 13 patients scanned using 16-MDCT, six different coronary anomalies were diagnosed [two absent left main, one single vessel left coronary artery (LCA), three LCA originating from the right (two with interarterial course), six right coronary artery originating from the left, one double left anterior descending (LAD)]. Mean diagnostic quality, recorded by two observers using a 5-point scale (1= non-diagnostic to 5= excellent diagnostic quality), resulted in a mean score of 3.73 (SD 1.19) without any non-diagnostic result. MDCT offers an accurate diagnostic modality to visualize the origin and course of anomalous coronary arteries by a three-dimensional display of anatomy. Shortcomings in CAG can be overcome by the use of contrast-enhanced MDCT. (orig.)

  19. Improving Image Quality of On-Board Cone-Beam CT in Radiation Therapy Using Image Information Provided by Planning Multi-Detector CT: A Phantom Study

    Yang, Ching-Ching; Chen, Fong-Lin; Lo, Yeh-Chi

    2016-01-01

    Purpose The aim of this study was to improve the image quality of cone-beam computed tomography (CBCT) mounted on the gantry of a linear accelerator used in radiation therapy based on the image information provided by planning multi-detector CT (MDCT). Methods MDCT-based shading correction for CBCT and virtual monochromatic CT (VMCT) synthesized using the dual-energy method were performed. In VMCT, the high-energy data were obtained from CBCT, while the low-energy data were obtained from MDCT...

  20. Dose-reduced 16-slice multidetector-row spiral computed tomography in children with bronchoscopically suspected vascular tracheal stenosis - initial results; Dosisreduzierte 16-Schicht-Multidetektor-Spiralcomputertomographie bei Saeuglingen und Kleinkindern mit bronchoskopischem Verdacht auf vaskulaer bedingte Trachealstenosen - erste klinische Ergebnisse

    Honnef, D.; Wildberger, J.E.; Das, M.; Hohl, C.; Mahnken, A.; Guenther, R.W.; Staatz, G. [Universitaetsklinikum der RWTH Aachen (Germany). Klinik fuer Radiologische Diagnostik; Schnoering, H.; Vazquez-Jimenez, J. [Universitaetsklinikum der RWTH Aachen (Germany). Klinik fuer Kinderherzchirurgie

    2006-04-15

    Purpose: To evaluate the diagnostic accuracy of contrast-enhanced dose-reduced 16-slice multidetector-row CT (MDCT) in newborns and infants with fiberoptic bronchoscopically suspected vascular-induced tracheal stenosis. Materials and Methods: 12 children (4 days to 3 years, 1.2-13.5 kg body weight) were examined using i.v. contrast-enhanced 16-slice MDCT (SOMATOM Sensation 16, Forchheim, Germany) without breath-hold and under sedation (11/12). All MDCTs were performed with a dose reduction. The beam collimation was 16 x 0.75 mm, except in the case of one child. MPRs along the tracheal axis in the x-, y- and z-directions and volume-rendering-reconstructions (VRTs) were calculated based on a secondary raw data set in addition to conventional axial slices. 2 radiologists used a three-point grade scale to evaluate the image quality, motion, and contrast media artifacts as well as the usefulness of the 2D- and 3D-reconstructions for determining the diagnosis. Statistical analysis was performed on the basis of a Kappa test. Results: In all cases the cause of the fiberoptic bronchoscopically suspected tracheal stenosis was revealed: compression due to the brachiocephalic trunk (n=7), double aortic arch (n=2), lusorian artery (n=1), vascular compression of the left main bronchus (n=2). In 3 patients further thoracic anomalies, such as tracheobronchial (n=2), and vascular (n=2) and vertebral (n=1) anomalies were found. The attenuation in the anomalous vessels was 307{+-}140 HU. The image noise was 9.8{+-}1.9 HU. The mean dose reduction was 82.7{+-}3.2% compared to a standard adult thoracic CT. All examinations were rated as diagnostically good (median 1, range 1, k=1). 3D images did not show any stair artifacts (median 2, range 1-2, k=1). The image noise was minor to moderate and hardly any motion artifacts were seen (median 1, range 1-2, k=0.8). Contrast media artifacts were rated zero to minor (median 1.5, range 1-2, k=0.676). MPRs (median 1, range 1, k=1) and VRTs

  1. Computed tomography of the intestinal tract, usage, advantages and disadvantages of this metod

    SMOLÁKOVÁ, Eva

    2007-01-01

    In presented essay author tries to offer comprehensive overview of possibilities of computer tomography (CT) in examination of the intestinal tract at her radiologic department. Introduction of Multidetector CT represents outstanding advance in spatial resolution in z - axis and accelerated data acquisition wihout increase of radiation dose. All these advantages of Multidetector CT project strongly onto examination of the intestines. At author´s department CT enterography and CT colonography ...

  2. Computed tomography of acute pulmonary embolism: state-of-the-art

    Zhang, Long Jiang; Lu, Guang Ming [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Meinel, Felix G.; McQuiston, Andrew D.; Ravenel, James G. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Schoepf, U.J. [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States)

    2015-09-15

    Multidetector computed tomography (CT) plays an important role in the detection, risk stratification and prognosis evaluation of acute pulmonary embolism. This review will discuss the technical improvements for imaging peripheral pulmonary arteries, the methods of assessing pulmonary embolism severity based on CT findings, a multidetector CT technique for pulmonary embolism detection, and lastly, how to avoid overutilization of CT pulmonary angiography and overdiagnosis of pulmonary embolism. (orig.)

  3. Performance of the multidetector NSE spectrometer SPAN at BENSC

    The NSE precession field, which is created by three pairs of coils with diameters 1, 3 and 4.8 m respectively, is the pecularity in the design of SPAN. Each pair is mounted in a Helmholtz-like fashion, with the electric currents oriented oppositely to each other, one coil above and one coil below the horizontal scattering plane. The maximum magnetic field integral is 0.06 T m typically 1/3 that of IN11. The field created by the coils with 3 m diameter is horizontal with axial symmetry. The coils with a diameter of 1 m shape the magnetic field around the sample. They produce at the sample a very homogeneous adjustable vertical field, which assures the axial symmetry of the magnetic configuration. A first series of NSE measurements are presented, which show that only little field adjustment is requires to satisfy the exact echo condition (phase) simultaneously for a large range of scattering angles and confirm the high axial symmetry of the precession field. The resolution of the spectrometer meets the expectations (∼ 8 ns maximum Fourier time at 9 A) and the results show that the new magnetic field configuration of SPAN is particularly appropriate for multidetector NSE over a wide angular range. (author)

  4. Cardiac causes of pulmonary arterial hypertension: assessment with multidetector CT

    Hoey, Edward T.D.; Gopalan, Deepa; Agrawal, S.K.B. [Papworth Hospital, Cambridge (United Kingdom); Screaton, Nicholas J. [Papworth Hospital, Cambridge (United Kingdom); Papworth Hospital NHS Trust, Diagnostic Centre, Department of Radiology, Papworth Everard, Cambridgeshire (United Kingdom)

    2009-11-15

    The causes of pulmonary arterial hypertension (PAH) are diverse and include multiple congenital and acquired cardiac diseases as well as diseases primarily affecting the pulmonary vasculature, lung, pleura and chest wall. The traditional role of CT in evaluating PAH includes assessment of pulmonary vasculature and lung parenchyma with limited assessment of the heart. Advances in multidetector CT technology with improved spatial and temporal resolution now permit accurate delineation of cardiac morphology. CT pulmonary angiography (CTPA) is widely utilised in the workup of patients with suspected pulmonary vascular disease and can identify both pulmonary and cardiac causes. As the initial presentation for CTPA is often precipitated by nonspecific, unexplained symptoms and therefore undertaken by a general radiologist, it is important that a systematic approach to the interpretation of these studies, including cardiac evaluation, is routinely adopted. This paper reviews the CT evaluation in pulmonary hypertension with a particular focus on the cardiac causes, their subclassification into congenital systemic to pulmonary shunts and secondary to left heart disease, and their imaging features. It emphasises the use of a systematic approach to interpretation of CTPA examinations both in patients with known PAH and those with previously unsuspected disease. (orig.)

  5. Multidetector CT findings of bowel Transection in blunt abdominal trauma

    Though a number of CT findings of bowel and mesenteric injuries in blunt abdominal trauma are described in literature, no studies on the specific CT signs of a transected bowel have been published. In the present study we describe the incidence and new CT signs of bowel transection in blunt abdominal trauma. We investigated the incidence of bowel transection in 513 patients admitted for blunt abdominal trauma who underwent multidetector CT (MDCT). The MDCT findings of 8 patients with a surgically proven complete bowel transection were assessed retrospectively. We report novel CT signs that are unique for transection, such as complete cutoff sign (transection of bowel loop), Janus sign (abnormal dual bowel wall enhancement, both increased and decreased), and fecal spillage. The incidence of bowel transection in blunt abdominal trauma was 1.56%. In eight cases of bowel transection, percentage of CT signs unique for bowel transection were as follows: complete cutoff in 8 (100%), Janus sign in 6 (100%, excluding duodenal injury), and fecal spillage in 2 (25%). The combination of complete cutoff and Janus sign were highly specific findings in patients with bowel transection. Complete cut off and Janus sign are the unique CT findings to help detect bowel transection in blunt abdominal trauma and recognition of these findings enables an accurate and prompt diagnosis for emergency laparotomy leading to reduced mortality and morbidity.

  6. Multidetector CT findings of bowel Transection in blunt abdominal trauma

    Cho, Hyun Suk; Woo, Ji Young; Hong, Hye Suk; Park, Mee Hyun; Yang, Ik; Lee, Yul; Jung, Ah Young; Hwang, Ji Young [Dept. of Radiology, Hallym University College of Medicine, Kangnam Sacred Heart Hospital, Seoul (Korea, Republic of); Ha, Hong Il [Dept. of Radiology, Hallym University College of Medicine, Hallym University Sacred Heart Hospital, Anyang (Korea, Republic of)

    2013-08-15

    Though a number of CT findings of bowel and mesenteric injuries in blunt abdominal trauma are described in literature, no studies on the specific CT signs of a transected bowel have been published. In the present study we describe the incidence and new CT signs of bowel transection in blunt abdominal trauma. We investigated the incidence of bowel transection in 513 patients admitted for blunt abdominal trauma who underwent multidetector CT (MDCT). The MDCT findings of 8 patients with a surgically proven complete bowel transection were assessed retrospectively. We report novel CT signs that are unique for transection, such as complete cutoff sign (transection of bowel loop), Janus sign (abnormal dual bowel wall enhancement, both increased and decreased), and fecal spillage. The incidence of bowel transection in blunt abdominal trauma was 1.56%. In eight cases of bowel transection, percentage of CT signs unique for bowel transection were as follows: complete cutoff in 8 (100%), Janus sign in 6 (100%, excluding duodenal injury), and fecal spillage in 2 (25%). The combination of complete cutoff and Janus sign were highly specific findings in patients with bowel transection. Complete cut off and Janus sign are the unique CT findings to help detect bowel transection in blunt abdominal trauma and recognition of these findings enables an accurate and prompt diagnosis for emergency laparotomy leading to reduced mortality and morbidity.

  7. First experiences with multidetector CT in traumatized children

    Introduction: The aim of this study was to describe and discuss first experiences with multidetector CT (MDCT) in the assessment of traumatized children. Material and methods: Since the implementation of a MDCT scanner in April 2002, 85 children (31 girls, 54 boys with a mean age of 9.2 years) consecutively underwent MDCT (Siemens, Erlangen, Germany) with different protocols depending on age, weight, trauma mechanism and clinical presentation. In all patients in whom pathology was suspected, multiplanar reformations (MPR) in coronal and or sagittal orientation was performed. Examinations were evaluated by two radiologists retrospectively and in consensus. Results: In 55 (65%) children, a MDCT solely of the head was performed, in 46 there was no pathology found. In six (7%), head and facial bones were scanned. Head and abdomen was examined in two (2%), in two (2%) the abdomen only and in one (1%) the pelvis solely. Scans of the spine were obtained in seven (8%) children. A thorax and abdomen examination only was obtained in one (1%) child each. In 11 (13%) children, a polytrauma protocol was performed. In all patients, the time of examination did not exceed 17 min, including setup time. All children survived at the writing of this report. Conclusion: MDCT was promising in the management of traumatized children and seems to shorten the necessary time to reach diagnosis and to initiate life-saving treatment

  8. Multidetector 4π INDRA Geometry simulation and silicon detectors study

    INDRA is a 4π detector of charged particles (p,d,t,α) and fragments (at least Z = 30) with an excellent space coverage (>80%). It consists of an assembly of 96 ionization chambers, 180 Silicon detectors (30 0), 324 caesium iodide scintillation detectors, and 12 NE102/NE115 scintillation detectors (200) distributed on 17 concentric rings. The detection thresholds are low and the dynamic range in energy is large (minimum 1000). A simulation of INDRA has been carried out in order to assist its technical realisation, the preparation of some experiments, and to guide the analysis of the experimental results according to the most frequently demanded areas of the multidetector. Specifically, identification matrices, both ionization chamber - silicon and caesium iodide - silicon, have been simulated to investigate these factors. The construction of the ring 4-5 (700) defines and suggests solutions for the major problems that will be encountered during the construction of the other rings, especially with the mechanical mounting of the silicon detectors. In addition, the study of the electronics associated with the silicon detectors has shown the necessity: - to devise specific amplifiers, on account of the excessive electronic noise of the amplifiers usually used. - to modify the manufacturing criteria of some of the silicon detectors manufacturing criterium (the metallization thickness on the side N+, the choice of high resistivities)

  9. Computed Tomography (CT) Perfusion in Abdominal Cancer

    Hansen, Martin Lundsgaard; Norling, Rikke; Lauridsen, Carsten;

    2013-01-01

    Computed Tomography (CT) Perfusion is an evolving method to visualize perfusion in organs and tissue. With the introduction of multidetector CT scanners, it is now possible to cover up to 16 cm in one rotation, and thereby making it possible to scan entire organs such as the liver with a fixed...

  10. 64排128层螺旋CT图像重建技术对胆脂瘤型中耳炎的术前评估价值%The Value of Preoperative Assessment about Otitis Media with Cholesteatoma by Image Reconstruction of 64-Multidetector 128-Slice Computer Tomography

    相丽; 郑穗生

    2011-01-01

    Obiective To explore the advantages and disadvantages of post-processing techniques of MSCT to the manifestation of bone destruction in ears with otitis media with cholesteatoma. Materials and Methods fmage reconstruction of 64-multidetector 128-slice CT were performed to middle and internal ears of 42 ears with otitis media with cholesteatoma in different ways. The images were compared to intraoperative findings, and the concordance of the two underwent Kappa test. SPSS was used to deal with the results. High concordance was defined as Kappa ≥0.75. Acceptable concordance was defined as 0. 41/Ukappa"00.75. Low concordance was defined as Kappa"U0.4. Results Kappa values of head of malleus, long crus of incus, short crus of incus, body of incus body, bone destruction of meningeal board, aditus ad antrum expanding and structure defects of horizontal segment of facial nerve canal were greater than 0.75L?Kappa values of handle of malleus, incudomelleolar joints, horizontal and labyrinthin segment of facial nerve canal, semicircular canal, scutum, bone wall of sigmoid sinus and bone destruction of labyrinth were between 0.4 and 0.75, but Kappa values of incudostapedial joint, anterior crus of stapes, posterior crus of stapes and bone destruction of footplate of stapes were less than 0.4. Conclusions Images of bone destruction in middle and internal ears with otitis media with cholesteatoma have important reference value for the operation.%目的 探讨MSCT后处理技术对胆脂瘤型中耳炎骨质破坏情况显示的优劣势.材料与方法 采用64排128层螺旋CT对42耳胆脂瘤型中耳炎中耳及内耳结构进行多种方式重建,结果与术中所见对照,Kappa检验二者的一致性,采用SPSS11.0软件包处理,规定 Kappa值大于或等于0.75为两者有很高的一致程度,其值在0.4-0.75说明一致程度尚可.小于0.4则说明一致程度不够理想.结果 锤骨头、砧骨长脚、砧骨短脚、砧骨体、脑膜板骨壁骨质破坏

  11. Use of multidetector row CT with volume renderings in right lobe living liver transplantation

    Multidetector row CT is a feasible diagnostic tool in pre- and postoperative liver partial transplantation. We can assess vascular anatomy and liver parenchyma as well as volumetry, which provide useful information for both donor selection and surgical planning. Disorders of the vascular and biliary systems are carefully observed in recipients. In addition, we evaluate liver regeneration of both the donor and the recipient by serial volumetry. We present how multidetector row CT with state-of-the-art three-dimensional volume renderings may be used in right lobe liver transplantation. (orig.)

  12. Search for continuous gravitational waves: metric of the multi-detector F-statistic

    Prix, R.

    2007-01-01

    We derive the parameter-space metric of the multi-detector F-statistic, which is the optimal detection statistic for continuous gravitational waves in stationary Gaussian noise. We find that there is a family of F-statistic metrics, parametrized by the (unknown) amplitude parameters. We explicitly derive the maximal mismatch-range of this metric family, and we introduce a corresponding "average" F-metric. We show that the multi-detector metric consists of noise-weighted averages of single-det...

  13. CT paging arteriography with a multidetector-row CT. Advantages in splanchnic arterial imaging

    Kobayashi, Seiji [Keio Univ., Tokyo (Japan). School of Medicine

    1999-11-01

    The purpose of this study is to assess the utility of CT paging arteriography with a multidetector-row CT as a replacement for conventional angiography in the evaluation of splanchnic arterial anomalies. Sixty-three patients underwent CT paging arteriography with a multidetector-row CT. In the 56 patients with conventional angiographic correlation, there was only one minor disagreement with CT paging arteriography. In the 7 patients who underwent IVDSA (intra venous digital subtraction angiography), CT paging arteriography defined four hepatic arterial anomalies which could not be depicted by IVDSA. In conclusion, CT paging arteriography provides noninvasive means to identify splanchnic arterial anomalies. (author)

  14. Introduction to coronary imaging with 64-slice Computed Tomography

    The aim of this article is to illustrate the main technical improvements in the last generation of 64-row CT scanners and the possible applications in coronary angiography. In particular, we describe the new physical components (X-ray tube-detectors system) and the general scan and reconstruction parameters. We then define the scan protocols for coronary angiography with the new generation of 64-row CT scanners to enable radiologists to perform a CT study on the basis of the diagnostic possibilities

  15. Multidetector CT and MRI in diseases of the GI tract

    With the introduction of spiral scanning then multidetector technologies, the accuracy for diagnosing digestive tract diseases with CT has been highly improved, and CT is used more and more in the evaluation of patients with suspected gastrointestinal disorders. CT is able to demonstrate both the intramural and the extra-mural components of the disease, and has a major role in the preoperative staging and the follow-up Improvements of CT protocols, such as CT-enteroclysis, or multiplanar 2D and 3D post-processing, including now techniques for 'virtual endoscopy', lead to discuss new indications in which CT could now compete with conventional X-rays series and video-endoscopy. This precise study of the digestive wall, the peri-digestive fat, the digestive tract blood supply, may be performed by MRI, under the condition of access to high level machines and standardized protocols. MR-enteroclysis and MR-virtual colonoscopy could be performed with much lower risk for the patient, in terms of radiation dose or contrast adverse effects. Endo-luminal coils should give to MR an ultra-high resolution for analysing the different layers of the gastrointestinal wall. Learning objectives: to review how to perform CT and MRI protocols for digestive tract imaging, to recognize the CT arid MR patterns of the main digestive tract diseases, to discuss the value, limits and role of CT and MR in digestive tract diseases, to discuss the potential role of CT and MR new technological developments for digestive tract imaging in the upcoming future Conclusion: CT is nowadays a modality of choice for digestive imaging. Improvements in technologies and indications, the necessary discussion of the risks and benefits for the patient should let the radiologists consider MRI in gastrointestinal disorders as an important part of the routine activity in clinical MRI. (authors)

  16. A project to design a software package for reporting multidetector CT (MDCT) doses

    Computed tomography (CT) has established itself as one of the most significant diagnostic technologies. The advent of the multidetector CT (MDCT) has made it possible to capture images to create 4D motion images for cardiac and respiratory diseases. As its usage grows, more concerns about the potential radiation risk to patients associated with various CT scanning protocols have raised from the medical imaging community and patients. This paper describes the effort to develop a modern software package to estimate and report the organ dose and effective dose values for patients undergoing the CT examinations. Original dose data were derived from a large number of Monte Carlo (MC) simulations based both on the ICRP 60 and ICRP 103 tissue-weighting coefficient using MCNPX v2.5, involving detailed CT scanner models and anatomically realistic phantoms. Detailed CT scanner X-ray sources and protocols are considered in the Monte Carlo simulations. Several of CT scanner series and different operated tube voltage have been taken into consideration. The RP1 Pregnant Women (RP1-P3, -P6 and -P9) and RP1 Adult Male (RPI-AM) and Adult Female (RPI-AF) are utilized as the phantom models. The software is being developed using the Visual C.NET platform with a graphical user interface (GUI) designed to allow a user to specify the patient type, body scan region, and scanner operating parameters. Using the object-oriented programming technology, 3D phantoms are displayed interactively to improve the user interaction with software functions. The organ dose and effective dose are rapidly archived and reported in the software according to the user-specified protocols. (authors)

  17. New absorbed dose measurement with cylindrical water phantoms for multidetector CT

    The aim of this study was to develop new dosimetry with cylindrical water phantoms for multidetector computed tomography (MDCT). The ionization measurement was performed with a Farmer ionization chamber at the center and four peripheral points in the body-type and head-type cylindrical water phantoms. The ionization was converted to the absorbed dose using a 60Co absorbed-dose-to-water calibration factor and Monte Carlo (MC) -calculated correction factors. The correction factors were calculated from MDCT (Brilliance iCT, 64-slice, Philips Electronics) modeled with GMctdospp (IMPS, Germany) software based on the EGSnrc MC code. The spectrum of incident x-ray beams and the configuration of a bowtie filter for MDCT were determined so that calculated photon intensity attenuation curves for aluminum (Al) and calculated off-center ratio (OCR) profiles in air coincided with those measured. The MC-calculated doses were calibrated by the absorbed dose measured at the center in both cylindrical water phantoms. Calculated doses were compared with measured doses at four peripheral points and the center in the phantom for various beam pitches and beam collimations. The calibration factors and the uncertainty of the absorbed dose determined using this method were also compared with those obtained by CTDIair (CT dose index in air). Calculated Al half-value layers and OCRs in air were within 0.3% and 3% agreement with the measured values, respectively. Calculated doses at four peripheral points and the centers for various beam pitches and beam collimations were within 5% and 2% agreement with measured values, respectively. The MC-calibration factors by our method were 44–50% lower than values by CTDIair due to the overbeaming effect. However, the calibration factors for CTDIair agreed within 5% with those of our method after correction for the overbeaming effect. Our method makes it possible to directly measure the absorbed dose for MDCT and is more robust and accurate than the

  18. New absorbed dose measurement with cylindrical water phantoms for multidetector CT

    Ohno, Takeshi; Araki, Fujio; Onizuka, Ryota; Hioki, Kazunari; Tomiyama, Yuuki; Yamashita, Yusuke

    2015-06-01

    The aim of this study was to develop new dosimetry with cylindrical water phantoms for multidetector computed tomography (MDCT). The ionization measurement was performed with a Farmer ionization chamber at the center and four peripheral points in the body-type and head-type cylindrical water phantoms. The ionization was converted to the absorbed dose using a 60Co absorbed-dose-to-water calibration factor and Monte Carlo (MC) -calculated correction factors. The correction factors were calculated from MDCT (Brilliance iCT, 64-slice, Philips Electronics) modeled with GMctdospp (IMPS, Germany) software based on the EGSnrc MC code. The spectrum of incident x-ray beams and the configuration of a bowtie filter for MDCT were determined so that calculated photon intensity attenuation curves for aluminum (Al) and calculated off-center ratio (OCR) profiles in air coincided with those measured. The MC-calculated doses were calibrated by the absorbed dose measured at the center in both cylindrical water phantoms. Calculated doses were compared with measured doses at four peripheral points and the center in the phantom for various beam pitches and beam collimations. The calibration factors and the uncertainty of the absorbed dose determined using this method were also compared with those obtained by CTDIair (CT dose index in air). Calculated Al half-value layers and OCRs in air were within 0.3% and 3% agreement with the measured values, respectively. Calculated doses at four peripheral points and the centers for various beam pitches and beam collimations were within 5% and 2% agreement with measured values, respectively. The MC-calibration factors by our method were 44-50% lower than values by CTDIair due to the overbeaming effect. However, the calibration factors for CTDIair agreed within 5% with those of our method after correction for the overbeaming effect. Our method makes it possible to directly measure the absorbed dose for MDCT and is more robust and accurate than the

  19. Novel ultrahigh resolution data acquisition and image reconstruction for multi-detector row CT

    We present and evaluate a special ultrahigh resolution mode providing considerably enhanced spatial resolution both in the scan plane and in the z-axis direction for a routine medical multi-detector row computed tomography (CT) system. Data acquisition is performed by using a flying focal spot both in the scan plane and in the z-axis direction in combination with tantalum grids that are inserted in front of the multi-row detector to reduce the aperture of the detector elements both in-plane and in the z-axis direction. The dose utilization of the system for standard applications is not affected, since the grids are moved into place only when needed and are removed for standard scanning. By means of this technique, image slices with a nominal section width of 0.4 mm (measured full width at half maximum=0.45 mm) can be reconstructed in spiral mode on a CT system with a detector configuration of 32x0.6 mm. The measured 2% value of the in-plane modulation transfer function (MTF) is 20.4 lp/cm, the measured 2% value of the longitudinal (z axis) MTF is 21.5 lp/cm. In a resolution phantom with metal line pair test patterns, spatial resolution of 20 lp/cm can be demonstrated both in the scan plane and along the z axis. This corresponds to an object size of 0.25 mm that can be resolved. The new mode is intended for ultrahigh resolution bone imaging, in particular for wrists, joints, and inner ear studies, where a higher level of image noise due to the reduced aperture is an acceptable trade-off for the clinical benefit brought about by the improved spatial resolution

  20. Paratracheal air cysts: prevalence and correlation with lung disease using multi-detector CT

    The purpose of this study was to determine the prevalence of paratracheal air cysts (PACs), their correlation with different lung diseases and their connection with the trachea by chest multi detector computed tomography (MDCT). We retrospectively reviewed chest MDCT images of 8240 consecutive patients obtained from January 2010 to December 2011 with a 16-detector multi-detector CT scanner. PACs were assessed for prevalence, location, level, size and the presence of visible communication with the trachea. MDCT diagnoses were classified as normal, primary or metastatic malignancies, chronic obstructive pulmonary disease (COPD), pneumonia and other lung diseases. We randomly selected 330 patients who had no visible PACs for the control group. We evaluated the associations between patients' demographic findings (age and sex), MDCT findings of lung and the presence of PACs. The findings of the PACs and control groups were compared. Statistical analysis used chi-squared test and Mann - Whitney U-test for evaluation. PACs were presented in 301 patients (4%); 204 men and 97 women, ranging in age from 14 to 91 years (median=57 years). There was no significant difference in the presence of PACs by age (P>0.05). Male subjects showed higher prevalence (P=0.005). Fifty PACs (16.6%) showed communication with the trachea or main bronchus. Although the relation between COPD and PACs was statistically significant (P<0.001), there was no relation between primary or metastatic malignancies, pneumonia and other lung diseases and PACs. PACs are common in MDCT and should not be misdiagnosed as pneumomediastinum. It should be kept in mind that PACs may be associated with COPD.

  1. Tuberculous Addison's disease: Morphological and quantitative evaluation with multidetector-row CT

    Ma Ensen [Department of Radiology, West China Hospital, Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Yang Zhigang [Department of Radiology, West China Hospital, Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China) and National Key Laboratory of Biotherapy Center, West China Hospital, Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China)]. E-mail: zgyang1117@yahoo.com.cn; Li Yuan [Department of Radiology, West China Hospital, Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Guo Yingkun [Department of Radiology, West China Hospital, Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Deng Yuping [Department of Radiology, West China Hospital, Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Zhang Xiaochun [Department of Radiology, West China Hospital, Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China)

    2007-06-15

    Objective: To determine the characteristics of tuberculous Addison's disease on the axial and multiplanar reformatted (MPR) images of the multidetector-row computed tomography (MDCT). Materials and methods: The unenhanced and contrast-enhanced MDCT features in 19 patients with tuberculous Addison's disease were retrospectively assessed for the location, contour, size, calcification, attenuation, and enhancement patterns. The correlation between the duration of Addison's disease and the percentage of calcification presence was evaluated. Results: The adrenal glands were infected bilaterally in all of the 19 cases (100%, 38 glands). Enlargement of the glands appeared in 18 cases (94.7%, 36 glands) and the remaining one case (5.3%, two glands) showed atrophy bilaterally. Of the 36 enlarged adrenals, 13 (36.1%) had preserved contours, and the other 23 (63.9%) were mass-like. The size of the adrenals ranged from 0.6 to 4.8cm (mean 1.92+/-0.96cm). Calcification was revealed in 16 adrenals (16/38, 42.1%), increasing in incidence with disease progression. Fourteen of the 36 (38.9%) enlarged adrenals showed peripheral enhancement while the remaining 22 (61.1%) demonstrated heterogeneous enhancement. The {delta}CT value, the attenuation measurement of mass-like lesions, was less in the central area (7+/-4HU) than that in the peripheral area (32+/-14HU) (P<0.01) between the unenhanced and contrast-enhanced scan. Conclusion: MDCT can reveal the characteristic morphology and CT attenuation in the tuberculous Addison's disease. Combined with its clinical presentations and biochemical findings, we can diagnose and stage adrenal tuberculosis with high specificity and accuracy on MDCT.

  2. Multidetector-row CT of tumour–bowel fistula: Experience at a tertiary cancer centre

    Aim: To study the clinical and multidetector computed tomography (MDCT) features of tumour–bowel fistula (TBF). Materials and methods: Fifty-one patients (27 women; mean age 57.4 years, range 30–77years) with TBF presenting to our institution between January 2005 and February 2012 were identified retrospectively from the radiology database. MDCT images before, at, and subsequent to diagnosis of TBF were reviewed by three radiologists in consensus; clinical presentation, management, and outcome were documented from electronic medical records. Results: Of 51 patients, small bowel (n = 22) was the most common site with gastrointestinal stromal tumour (GIST) being the most common sarcoma subtype (n = 10). TBF was treatment-associated (TTBF) in 40 patients [78%; 22 of whom had received molecular targeted therapy (MTT)], and spontaneous (STBF) in 11 patients (22%). Thirty-one patients (61%) were symptomatic at the time of TBF detection. TTBF was more often asymptomatic (19/40 versus 1/11; Fisher's exact test p = 0.03). In the TTBF group, 16 had a partial response, seven had stable disease, and 17 had progressive disease. Treatment was discontinued or changed to an alternative regimen in 27/40 patients, and 13/40 patients continued with the same regimen. TBF persisted in 27/33 patients (82%) who underwent CT follow-up. Thirty-one of the 51 patients were deceased at the time of analysis. Time from diagnosis of TBF to death was shorter with STBF (1.8 months) than with TTBF (6.4 months). Conclusion: TBF is often associated with MTT and can be seen with treatment response or progression. TTBF is more frequently asymptomatic. TBF is usually managed conservatively by discontinuing treatment, but often persists on CT follow-up

  3. Carotid artery wall thickness: comparison between sonography and multi-detector row CT angiography

    Saba, Luca [University of Cagliari, Department of Radiology, Policlinico Universitario, Cagliari (Italy); Sanfilippo, Roberto; Montisci, Roberto [Policlinico Universitario, Department of Vascular Surgery, Cagliari (Italy); Mallarini, Giorgio [University of Cagliari, Department of Radiology, Policlinico Universitario, Cagliari (Italy); Ospedale San Giovanni di Dio, Institute of Radiology, Cagliari (Italy)

    2010-02-15

    Prospective studies have shown that an increased thickness of the carotid wall is a significant predictor of coronary and cerebrovascular complications. Our purpose was to assess the agreement between multi-detector row computed tomography (CT) angiography (MDCTA) and colour Doppler ultrasound (CD-US) in measuring carotid artery wall thickness (CAWT) and the intima-media thickness (IMT). Altogether, 97 subjects (age range 64-84 years) were prospectively analysed using a four-detector row CT and a sonographic scanner. In total, 46 subjects had shown cerebral ischaemic symptoms. CAWT and IMT were measured in each patient using MDCTA and CD-US (by applying a digital calliper), respectively. Continuous data were described as the mean value {+-} standard deviation and were compared using the Mann-Whitney U test. A p value <0.05 was considered significant. Bland-Altman statistics was employed to measure the agreement between MDCTA and CD-US. CAWT ranged from 0.5 to 1.53 mm, with a mean value of 0.9072 mm. IMT ranged from 0.46 to 1.5 mm, with a mean value of 0.8839 mm. By analysing the Bland-Altman plot, we observed an excellent agreement between CD-US and MDCTA with a bias between methods of 0.023 {+-} 0.0424 mm. A limit of agreement from -0.06 to 0.106 was recorded. Correlation coefficient r was 0.9855 (95% confidence interval 0.9808-0.989). Mann-Whitney U test indicated a p value of 0.377. Obtained results indicated a significant agreement between MDCTA and CD-US in the measurement of CAWT and IMT. (orig.)

  4. Carotid artery wall thickness: comparison between sonography and multi-detector row CT angiography

    Prospective studies have shown that an increased thickness of the carotid wall is a significant predictor of coronary and cerebrovascular complications. Our purpose was to assess the agreement between multi-detector row computed tomography (CT) angiography (MDCTA) and colour Doppler ultrasound (CD-US) in measuring carotid artery wall thickness (CAWT) and the intima-media thickness (IMT). Altogether, 97 subjects (age range 64-84 years) were prospectively analysed using a four-detector row CT and a sonographic scanner. In total, 46 subjects had shown cerebral ischaemic symptoms. CAWT and IMT were measured in each patient using MDCTA and CD-US (by applying a digital calliper), respectively. Continuous data were described as the mean value ± standard deviation and were compared using the Mann-Whitney U test. A p value <0.05 was considered significant. Bland-Altman statistics was employed to measure the agreement between MDCTA and CD-US. CAWT ranged from 0.5 to 1.53 mm, with a mean value of 0.9072 mm. IMT ranged from 0.46 to 1.5 mm, with a mean value of 0.8839 mm. By analysing the Bland-Altman plot, we observed an excellent agreement between CD-US and MDCTA with a bias between methods of 0.023 ± 0.0424 mm. A limit of agreement from -0.06 to 0.106 was recorded. Correlation coefficient r was 0.9855 (95% confidence interval 0.9808-0.989). Mann-Whitney U test indicated a p value of 0.377. Obtained results indicated a significant agreement between MDCTA and CD-US in the measurement of CAWT and IMT. (orig.)

  5. Multi-detector row CT for depicting anatomic features of cephalothoracopagus varieties: revised approach.

    Grassi, Roberto; Esposito, Vincenzo; Scaglione, Mariano; Cirillo, Mario; Cappabianca, Salvatore; Guglielmi, Giuseppe; Sasso, Francesco Silvano; Rotondo, Antonio

    2004-01-01

    Conjoined twins can be classified on the basis of the site of union; thus, three main types can be described: (a) ventral union, (b) dorsal union, and (c) rarer forms of union. Ventral union is characterized by the fusion of the two embryos on the ventral side (eg, the abdomen). Dorsal union twins are joined on the dorsal aspect (eg, the vertebral column or occipital bone). Ventral union twins include the group of crucipage twins (ventral midline structures at 90 degrees to the dorsal midline structures), which show interesting features in the organization of the midline. Twins conjoined at the head and chest are called cephalothoracopagus twins. The cephalothoracopagus variety called "Janus" is characterized by the presence of two opposite faces, which are composite structures half of which belong to one twin and half to the other. A complete set of five variants of cephalothoracopagus is presented and, to the authors' knowledge, analyzed for the first time with multi-detector row helical computed tomography. This modality is an invaluable tool for obtaining high-resolution images of the brain, chest, abdomen, and spine and for demonstrating organ position, shared viscera, and limited vascular anatomy. In addition, data acquired in three-dimensional volumes can further be manipulated and then reconstructed. For this purpose, the authors developed dedicated software for three-dimensional reconstruction to analyze data from specimens preserved in formalin. The anatomic findings are discussed here for their embryologic value and to revise the classification of cephalothoracopagus twins. These data offer detailed information for accurate comprehension of imaging studies and for theoretical studies concerning the formation of several anatomic structures. PMID:15249653

  6. Study of statistical properties of hybrid statistic in coherent multidetector compact binary coalescences search

    Haris, K.; Pai, Archana

    2016-05-01

    In this article, we revisit the coherent gravitational wave search problem of compact binary coalescences with multidetector network consisting of advanced interferometers like LIGO-Virgo. Based on the loss of the optimal multidetector signal-to-noise ratio (SNR), we construct a hybrid statistic as a best of maximum-likelihood-ratio (MLR) statistic tuned for face-on and face-off binaries. The statistical properties of the hybrid statistic is studied. The performance of this hybrid statistic is compared with that of the coherent MLR statistic for generic inclination angles. Owing to the single synthetic data stream, the hybrid statistic gives few false alarms compared to the multidetector MLR statistic and small fractional loss in the optimum SNR for a large range of binary inclinations. We demonstrate that, for a LIGO-Virgo network and binary inclination ɛ 11 0 ° , the hybrid statistic captures more than 98% of the network optimum matched filter SNR with a low false alarm rate. The Monte Carlo exercise with two distributions of incoming inclination angles—namely, U [cos ɛ ] and a more realistic distribution proposed by B. F. Schutz [Classical Quantum Gravity 28, 125023 (2011)]—are performed with the hybrid statistic and give approximately 5% and 7% higher detection probabilities, respectively, compared to the two stream multidetector MLR statistic for a fixed false alarm probability of 1 0-5.

  7. Application of multi-detector row helical scanning to postmyelographic CT

    The advent of a multi-detector row helical CT has made it possible to attain images over a broader area with good spatial resolution. We assessed whether postmyelographic CT scans obtained using this system provided more information than conventional imaging techniques. Postmyelographic CT scans were preoperatively obtained in 46 patients using a multi-detector row helical CT system. Reconstructed images in the sagittal and coronal planes in all patients and curved reformation images along the dural sac in 37 patients were compared with myelograms and conventional postmyelographic CT scans. In 34 patients comparison was also made with MR images. The multi-detector row CT images demonstrated deformities of the dural sac more clearly than the other modalities in 39 of the 46 patients. They also provided the best visualization of nerve root abnormalities in 24 of the 46 patients and clearly revealed the presence of spurs in all 22 patients with spinal canal stenosis. Postmyelographic CT scans made using a multi-detector row helical CT system provide more information on the dural sac, nerve sleeves, and their contents than other imaging techniques. (orig.)

  8. Detection, characterization and endovascular therapy planning of intracranial aneurysms with 16-channel multidetector row CT angiography

    Amr Badry

    2014-03-01

    Conclusion: Sixteen channel Multidetector CT angiography offers high diagnostic accuracy nearly equivalent to that of DSA in the detection of intracranial aneurysms. However, 16 channel- MDCTA still has limited sensitivity in detecting aneurysms of 3 mm or less, despite its technical advances. MDCT can be used as a reliable alternative imaging technique to DSA in selected cases.

  9. Setting graphic software for data examination of multidetector used in heavy ions physic

    In this work, the first chapter presents both the multidetectors of the vacuum chamber NAUTILUS, from a geometrical and parametrical point of view and the manual analysis phase. The second part deals with the main notions of the language Graphical Kernel System. Finally, the third chapter is a presentation of the different graphical programs written in order to accelerate and rationalize the analysis phase

  10. Multi-detector setup for nuclear astrophysical reaction studies on the low energy ion beam

    The multi-detector setup assembled on the basis of the ion beam from 'SOKOL' electrostatic accelerator is described. The setup allows one to measure three various spectra in a single experiment: prompt gamma-quanta from nuclear reactions, positrons from the decays of radioactive nuclei formed in the reactions and coincidence spectrum of annihilation gamma-quanta. (authors)

  11. Pancreatic pseudoaneurysm in a child with hereditary pancreatitis: diagnosis with multidetector CT angiography

    Ahmed, Hossam K.; Hagspiel, Klaus D.; Angle, John F.; Leung, Daniel A.; Spinosa, David J.; Matsumoto, Alan H. [Department of Radiology, University of Virginia Health System, Box 800170, VA 22908, Charlottesville (United States); McGahren, Eugene D.; Rodgers, Bradley M. [Department of Surgery, Division of Pediatric Surgery, University of Virginia Health System, Box 800170, VA 22908, Charlottesville (United States)

    2004-08-01

    Pseudoaneurysm formation is a serious vascular complication of pancreatitis. It most commonly affects splenic and gastroduodenal arteries. We report a rare case of superior mesenteric artery pseudoaneurysm in a child with hereditary pancreatitis. Multidetector CT angiography allowed the comprehensive assessment of the aneurysm and allowed accurate surgical planning obviating the need for catheter angiography. (orig.)

  12. Pancreatic pseudoaneurysm in a child with hereditary pancreatitis: diagnosis with multidetector CT angiography

    Pseudoaneurysm formation is a serious vascular complication of pancreatitis. It most commonly affects splenic and gastroduodenal arteries. We report a rare case of superior mesenteric artery pseudoaneurysm in a child with hereditary pancreatitis. Multidetector CT angiography allowed the comprehensive assessment of the aneurysm and allowed accurate surgical planning obviating the need for catheter angiography. (orig.)

  13. Comparison of effective dose for imaging of mandible between multi-detector CT and cone-beam CT

    Jeong, Dae Kyo; Lee, Sang Chul; Huh, Kyung Hoe; Yi, Won Jin; Lee, Sam Sun; Choi, Soon Chul [School of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    2012-06-15

    The aim of this study was to compare the effective dose for imaging of mandible between multi-detector computed tomography (MDCT) and cone-beam computed tomography (CBCT). An MDCT with low dose technique was also compared with them. Thermoluminescent dosimeter (TLD) chips were placed at 25 organ sites of an anthropomorphic phantom. The mandible of the phantom was exposed using 2 different types of MDCT units (Somatom Sensation 10 for standard-dose MDCT, Somatom Emotion 6 for low-dose MDCT) and 3 different CBCT units (AZ3000CT, Implagraphy, and Kavo 3D eXaM). The radiation absorbed dose was measured and the effective dose was calculated according to the ICRP 2007 report. The effective dose was the highest for Somatom Sensation 10 (425.84 {mu}Sv), followed by AZ3000CT (332.4 {mu}Sv), Somatom Emotion 6 (199.38 {mu}Sv), and 3D eXaM (111.6 {mu}Sv); it was the lowest for Implagraphy (83.09 {mu}Sv). The CBCT showed significant variation in dose level with different device. The effective doses of MDCTs were not significantly different from those of CBCTs for imaging of mandible. The effective dose of MDCT could be markedly decreased by using the low-dose technique.

  14. Comparison of effective dose for imaging of mandible between multi-detector CT and cone-beam CT

    The aim of this study was to compare the effective dose for imaging of mandible between multi-detector computed tomography (MDCT) and cone-beam computed tomography (CBCT). An MDCT with low dose technique was also compared with them. Thermoluminescent dosimeter (TLD) chips were placed at 25 organ sites of an anthropomorphic phantom. The mandible of the phantom was exposed using 2 different types of MDCT units (Somatom Sensation 10 for standard-dose MDCT, Somatom Emotion 6 for low-dose MDCT) and 3 different CBCT units (AZ3000CT, Implagraphy, and Kavo 3D eXaM). The radiation absorbed dose was measured and the effective dose was calculated according to the ICRP 2007 report. The effective dose was the highest for Somatom Sensation 10 (425.84 μSv), followed by AZ3000CT (332.4 μSv), Somatom Emotion 6 (199.38 μSv), and 3D eXaM (111.6 μSv); it was the lowest for Implagraphy (83.09 μSv). The CBCT showed significant variation in dose level with different device. The effective doses of MDCTs were not significantly different from those of CBCTs for imaging of mandible. The effective dose of MDCT could be markedly decreased by using the low-dose technique.

  15. Lung Nodule Detection in Screening Computed Tomography

    Gori, I; Cerello, P; Cheran, S C; De Nunzio, G; Fantacci, M E; Kasae, P; Masala, G L; Pérez-Martínez, A; Retico, A

    2007-01-01

    A computer-aided detection (CAD) system for the identification of pulmonary nodules in low-dose multi-detector helical Computed Tomography (CT) images with 1.25 mm slice thickness is presented. The basic modules of our lung-CAD system, a dot-enhancement filter for nodule candidate selection and a neural classifier for false-positive finding reduction, are described. The results obtained on the collected database of lung CT scans are discussed.

  16. The Utility of 64 Channel Multidetector CT Angiography for Evaluating the Renal Vascular Anatomy and Possible Variations: a Pictorial Essay

    The increased use of laparoscopic nephrectomy and nephron-sparing surgery has prompted the need for a more detailed radiological evaluation of the renal vascular anatomy. Multidetector CT angiography is a fast and accurate modality for assessing the precise anatomy of the renal vessels. In this pictorial review, we present the multidetector CT angiography appearances of the normal renal vascular anatomy and a spectrum of various anomalies that require accurate vascular depiction before undergoing surgical treatment

  17. COMPUTING

    M. Kasemann

    Overview In autumn the main focus was to process and handle CRAFT data and to perform the Summer08 MC production. The operational aspects were well covered by regular Computing Shifts, experts on duty and Computing Run Coordination. At the Computing Resource Board (CRB) in October a model to account for service work at Tier 2s was approved. The computing resources for 2009 were reviewed for presentation at the C-RRB. The quarterly resource monitoring is continuing. Facilities/Infrastructure operations Operations during CRAFT data taking ran fine. This proved to be a very valuable experience for T0 workflows and operations. The transfers of custodial data to most T1s went smoothly. A first round of reprocessing started at the Tier-1 centers end of November; it will take about two weeks. The Computing Shifts procedure was tested full scale during this period and proved to be very efficient: 30 Computing Shifts Persons (CSP) and 10 Computing Resources Coordinators (CRC). The shift program for the shut down w...

  18. Deepgoing study on intrathoracic tuberculous lymphadenitis in adults using multidetector CT

    LUO Ming-yue; LIU Li; LAI Li-sha; DONG Yun-xu; LIANG Wen-wei; QIN Jie

    2010-01-01

    Background Studies on intrathoracic tuberculous lymphadenitis in adults are confined to the preliminary CT findings with ordinary CT and ordinary spiral CT.There has been no deepgoing study of multidetector CT to date.Multidetector CT could contribute to better imaging of intrathoracic tuberculous lymphadenitis in adults.The purpose of this study was to explore the multidetector CT features of intrathoracic tuberculous lymphadenitis in adults, and the correlation with clinical symptoms and pathologic changes.Methods Multidetector CT findings from 42 consecutive adult patients with intrathoracic tuberculous lymphadenitis were analyzed retrospectively with regard to locations, sizes, numbers, shapes, margins, and densities reviewing precontrast and enhanced images.CT results were correlated with clinical symptoms and pathologic results (n=37).Results One hundred and eighty-five intrathoracic lymph nodes that had tuberculous lymphadenitis in 42 patients were distributed mainly in regions 4R (n=37), 2R (n=33), 7 (n=31) and 10R (n=21), more than 2 regions were implicated in 34 patients.One hundred and twenty-two (72.2%) of the tuberculous lymphadenitis without confluence were oval or round with clear margins.On precontrast scanning, 78.4% of tuberculous lymphadenitis had a homogeneous density.Seven enhancement patterns were demonstrated in 169 tuberculous lymphadenitis from 37 patients with pathologic results:homogeneous enhancement with no clinical symptom (n=12), corresponded pathologically to tuberculous hyperplasia without caseous necrosis; heterogeneous enhancement with a small central no enhancement area, slight clinical symptoms (n=22), tuberculous granulomas with a little caseous necroses; peripheral irregular thick wall enhancement with a central area with no enhancement, slight clinical symptoms (n=52), tuberculous granulomas with some caseous necroses in the center; peripheral thin rim enhancement with a central area having no enhancement, moderate clinical

  19. COMPUTING

    P. McBride

    The Computing Project is preparing for a busy year where the primary emphasis of the project moves towards steady operations. Following the very successful completion of Computing Software and Analysis challenge, CSA06, last fall, we have reorganized and established four groups in computing area: Commissioning, User Support, Facility/Infrastructure Operations and Data Operations. These groups work closely together with groups from the Offline Project in planning for data processing and operations. Monte Carlo production has continued since CSA06, with about 30M events produced each month to be used for HLT studies and physics validation. Monte Carlo production will continue throughout the year in the preparation of large samples for physics and detector studies ramping to 50 M events/month for CSA07. Commissioning of the full CMS computing system is a major goal for 2007. Site monitoring is an important commissioning component and work is ongoing to devise CMS specific tests to be included in Service Availa...

  20. COMPUTING

    I. Fisk

    2011-01-01

    Introduction CMS distributed computing system performed well during the 2011 start-up. The events in 2011 have more pile-up and are more complex than last year; this results in longer reconstruction times and harder events to simulate. Significant increases in computing capacity were delivered in April for all computing tiers, and the utilisation and load is close to the planning predictions. All computing centre tiers performed their expected functionalities. Heavy-Ion Programme The CMS Heavy-Ion Programme had a very strong showing at the Quark Matter conference. A large number of analyses were shown. The dedicated heavy-ion reconstruction facility at the Vanderbilt Tier-2 is still involved in some commissioning activities, but is available for processing and analysis. Facilities and Infrastructure Operations Facility and Infrastructure operations have been active with operations and several important deployment tasks. Facilities participated in the testing and deployment of WMAgent and WorkQueue+Request...

  1. COMPUTING

    M. Kasemann

    Overview During the past three months activities were focused on data operations, testing and re-enforcing shift and operational procedures for data production and transfer, MC production and on user support. Planning of the computing resources in view of the new LHC calendar in ongoing. Two new task forces were created for supporting the integration work: Site Commissioning, which develops tools helping distributed sites to monitor job and data workflows, and Analysis Support, collecting the user experience and feedback during analysis activities and developing tools to increase efficiency. The development plan for DMWM for 2009/2011 was developed at the beginning of the year, based on the requirements from the Physics, Computing and Offline groups (see Offline section). The Computing management meeting at FermiLab on February 19th and 20th was an excellent opportunity discussing the impact and for addressing issues and solutions to the main challenges facing CMS computing. The lack of manpower is particul...

  2. Evaluation of middle cerebral artery stents using multidetector row CT angiography in vivo study: comparison of the three different kernels

    Background: There are very few reports assessing middle cerebral artery (MCA) stents using multidetector computed tomography (MDCT). Purpose: To assess MCA stents using multidetector CT angiography (CTA) in vivo evaluation: the differences in the CTA results according to the three different kernels. Material and Methods: We retrospectively evaluated 27 MCA stents from 26 patients who underwent CTA with 16- and 64-slice MDCT after percutaneous transluminal angioplasty and stenting (PTAS). By CTA, using medium-smooth kernel (B30), medium-sharp kernel (B50), and sharp kernel (B60), the lumen diameter, artificial luminal narrowing (ALN), and subjective visibility score of the stented vessels were evaluated. The subjective visibility score ranged from 1 (poor quality) to 5 (excellent) using a five-point scale. Results: There were excellent inter-observer agreements for the lumen diameter measurements (P < 0.001). The mean diameter of the stented vessels was 2.10 ± 0.31 mm on digital subtraction angiography (DSA), 0.93 ± 0.20 mm on CTA using B30, 1.18 ± 0.27 mm on CTA using B50, and 1.29 ± 0.29 mm on CTA using B60. The mean ALN was 55.7 ± 6.0% on CTA using B30, 43.8 ± 7.5% on CTA using B50, and 38.7 ± 8.3% on CTA using B60. CTA with higher kernels had a smaller ALN than images with smaller kernels. The median subjective visibility score on the CTA using B50 was 3, which was higher than for the other kernels. The differences in the lumen diameter, ALN, and the subjective visibility score of the stented vessels on CTA using the three different kernels was statistically significant (P < 0.001). Conclusion: The sharp kernel was better to assess the lumen diameter and ALN, but was inferior to the medium-sharp kernel for in-stent evaluation due to high image-to-noise. CTA with medium-sharp kernel showed good lumen visibility and acceptable ALN for MCA stents. This could therefore be a non-invasive, readily applicable clinical method for assessing MCA stent patency after

  3. Evaluation of middle cerebral artery stents using multidetector row CT angiography in vivo study: comparison of the three different kernels

    Jang, Jin Hee; Lim, Yeon Soo; Lee, Youn Joo; Yoo, Won Jong; Sung, Mi Sook (Dept. of Radiology, Bucheon St Mary' s Hospital, Coll. of Medicine, The Catholic Univ. of Korea, Bucheon (Korea, Republic of)), email: wjyu@catholic.ac.kr; Kim, Bum Soo (Dept. of Radiology, Seoul St Mary' s Hospital, Coll. of Medicine, The Catholic Univ. of Korea, Seoul (Korea, Republic of))

    2012-05-15

    Background: There are very few reports assessing middle cerebral artery (MCA) stents using multidetector computed tomography (MDCT). Purpose: To assess MCA stents using multidetector CT angiography (CTA) in vivo evaluation: the differences in the CTA results according to the three different kernels. Material and Methods: We retrospectively evaluated 27 MCA stents from 26 patients who underwent CTA with 16- and 64-slice MDCT after percutaneous transluminal angioplasty and stenting (PTAS). By CTA, using medium-smooth kernel (B30), medium-sharp kernel (B50), and sharp kernel (B60), the lumen diameter, artificial luminal narrowing (ALN), and subjective visibility score of the stented vessels were evaluated. The subjective visibility score ranged from 1 (poor quality) to 5 (excellent) using a five-point scale. Results: There were excellent inter-observer agreements for the lumen diameter measurements (P < 0.001). The mean diameter of the stented vessels was 2.10 +- 0.31 mm on digital subtraction angiography (DSA), 0.93 +- 0.20 mm on CTA using B30, 1.18 +- 0.27 mm on CTA using B50, and 1.29 +- 0.29 mm on CTA using B60. The mean ALN was 55.7 +- 6.0% on CTA using B30, 43.8 +- 7.5% on CTA using B50, and 38.7 +- 8.3% on CTA using B60. CTA with higher kernels had a smaller ALN than images with smaller kernels. The median subjective visibility score on the CTA using B50 was 3, which was higher than for the other kernels. The differences in the lumen diameter, ALN, and the subjective visibility score of the stented vessels on CTA using the three different kernels was statistically significant (P < 0.001). Conclusion: The sharp kernel was better to assess the lumen diameter and ALN, but was inferior to the medium-sharp kernel for in-stent evaluation due to high image-to-noise. CTA with medium-sharp kernel showed good lumen visibility and acceptable ALN for MCA stents. This could therefore be a non-invasive, readily applicable clinical method for assessing MCA stent patency after

  4. Reducing radiation dose in 64-row spiral CT coronary angiography: study based on individualized scan dosage protocol

    Objective: To investigate the methods of reducing radiation dose in CT coronary angiography through optimizing individualized scan dosage protocol. Methods: Two hundred patients (group A) underwent coronary CTA examination which was performed with fixed 120 kV and variable mA according to their BMI. The mA was set as 150-300 mA (BMI < 18.5 kg/m2), 300-500 mA (18.5 kg/m2 ≤ BMI < 25.0 kg/m2), and 500-800 mA (BMI ≥ 25.0 kg/m2). When all examinations were finished, a linear regression was employed to analyze the correlation between mA and BMI, body surface (Suf), image noise (SD) respectively. The results of the analysis were used to formulate a regression equation, which was further used to establish a table list for quick search on how much mA that individualized coronary CTA scan would need. Another 200 patients (group B) enrolled for the individualized scan were scanned under new protocol that previous study established. The tube voltage was 100 and 120 kV. The tube current was variable according to the data in the table list. One-way ANOVA and Kruskal-wallis H test were used for statistics. Results: Regression equation between mA and BMI, Suf, SD was: mA =17.984 × BMI + 169.149 × Suf-2.282 × SD-361.039. The SD (group A: 32.08 ± 5.80, group B: 28.60±4.47), dose index volume (CTDIvol) [group A: (41.97 ± 11.37) mGy, group B: (33.18±10.07) mGy], effective dose(ED) [group A: (10.91 ±3.07) mSy, group B: (8.83 ±2.72)mSv] had significant differences between the two groups (F=43.45, 63.71, 49.07 respectively, P<0.01 for all). The SD and ED results obtained in group B were better than those in group A. Conclusion: Better performances were obtained when BMI combined Suf was used as a new individualized protocol than when BMI was used only, which means good image quality and lower radiation dosage in coronary CTA examination. (authors)

  5. Dual-energy CT revisited with multidetector CT: review of principles and clinical applications.

    Karçaaltıncaba, Muşturay; Aktaş, Aykut

    2011-09-01

    Although dual-energy CT (DECT) was first conceived in the 1970s, it was not widely used for CT indications. Recently, the simultaneous acquisition of volumetric dual-energy data has been introduced using multidetector CT (MDCT) with two X-ray tubes and rapid kVp switching (gemstone spectral imaging). Two major advantages of DECT are material decomposition by acquiring two image series with different kVp and the elimination of misregistration artifacts. Hounsfield unit measurements by DECT are not absolute and can change depending on the kVp used for an acquisition. Typically, a combination of 80/140 kVp is used for DECT, but for some applications, 100/140 kVp is preferred. In this study, we summarized the clinical applications of DECT and included images that were acquired using the dual-source CT and rapid kVp switching. In general, unenhanced images can be avoided by using DECT for body and neurological applications; iodine can be removed from the image, and a virtual, non-contrast (water) image can be obtained. Neuroradiological applications allow for the removal of bone and calcium from the carotid and brain CT angiography. Thorax applications include perfusion imaging in patients with pulmonary thromboemboli and other chest diseases, xenon ventilation-perfusion imaging and solitary nodule characterization. Cardiac applications include dual-energy cardiac perfusion, viability and cardiac iron detection. The removal of calcific plaques from arteries, bone removal and aortic stent graft evaluation may be achieved in the vascular system. Abdominal applications include the detection and characterization of liver and pancreas masses, the diagnosis of steatosis and iron overload, DECT colonoscopy and CT cholangiography. Urinary system applications are urinary calculi characterization (uric acid vs. non-uric acid), renal cyst characterization and mass characterization. Musculoskeletal applications permit the differentiation of gout from pseudogout and a reduction of

  6. 64-slice multidetector coronary CT angiography: in vitro evaluation of 68 different stents

    Maintz, David; Seifarth, Harald; Rink, Michael; Oezguen, Murat; Heindel, Walter; Fischbach, Roman [University of Muenster, Department of Clinical Radiology, Muenster (Germany); Raupach, Rainer; Flohr, Thomas [Siemens Medical Solutions, Forchheim (Germany); Sommer, Torsten [University of Bonn, Department of Radiology, Bonn (Germany)

    2006-04-15

    The purpose of this study was to test a large sample of different coronary artery stents using four image reconstruction approaches with respect to lumen visualization, lumen attenuation, and image noise in 64-slice multidetector-row computed tomography (MDCT) in vitro and to provide a catalogue of currently used coronary artery stents when imaged with state-of the-art MDCT. We examined 68 different coronary artery stents (57 stainless steel, four cobalt-chromium, one cobalt-alloy, two nitinol, four tantalum) in a coronary artery phantom (vessel diameter 3 mm, intravascular attenuation 250 HU, extravascular density -70). Stents were imaged in axial orientation with standard parameters: 32x0.6 collimation, pitch 0.24, 680 mAs, 120 kV, rotation time 0.37 s. Four different image reconstructions were obtained with varying convolution kernels and section thicknesses: (1) soft, 0.6 mm, (2) soft, 0.75, (3) medium soft, 0.6, and (4) stent-optimized sharp, 0.6. To evaluate visualization characteristics of of the stent, the lumen diameter, intraluminal density and noise were measured. The high-resolution kernel offered significantly better average lumen visualization (57% {+-}10%) and more realistic lumen attenuation (222 HU {+-}66 HU) at the expense of increased noise (15.3 HU {+-}3.7 HU) compared with the soft and medium-soft CT angiography (CTA) protocol (p<0.001 for all). Stents with a lumen visibility of more than 66% were: Arthos pico, Driver, Flex, Nexus2, S7, Tenax complete, Vision (all 67%), Symbiot, Teneo (70%), and Radius (73%). Only ten stents showed a lumen visibility of less than 50%. Stent lumen visibility largely varies depending on the stent type. Even with the improved spatial resolution of 64-slice CT, a stent-optimized kernel remains beneficial for stent visualization when compared with the standard medium-soft CTA protocol. Using 64-slice CT and high-resolution kernel, the majority of stent products show a lumen visibility of more than 50% of the stent

  7. COMPUTING

    I. Fisk

    2013-01-01

    Computing activity had ramped down after the completion of the reprocessing of the 2012 data and parked data, but is increasing with new simulation samples for analysis and upgrade studies. Much of the Computing effort is currently involved in activities to improve the computing system in preparation for 2015. Operations Office Since the beginning of 2013, the Computing Operations team successfully re-processed the 2012 data in record time, not only by using opportunistic resources like the San Diego Supercomputer Center which was accessible, to re-process the primary datasets HTMHT and MultiJet in Run2012D much earlier than planned. The Heavy-Ion data-taking period was successfully concluded in February collecting almost 500 T. Figure 3: Number of events per month (data) In LS1, our emphasis is to increase efficiency and flexibility of the infrastructure and operation. Computing Operations is working on separating disk and tape at the Tier-1 sites and the full implementation of the xrootd federation ...

  8. Multidetector CT radiation dose optimisation in adults: short- and long-term effects of a clinical audit

    To report short- and long-term effects of an audit process intended to optimise the radiation dose from multidetector row computed tomography (MDCT). A survey of radiation dose from all eight MDCT departments in the state of Luxembourg performed in 2007 served as baseline, and involved the most frequently imaged regions (head, sinus, cervical spine, thorax, abdomen, and lumbar spine). CT dose index volume (CTDIvol), dose-length product per acquisition (DLP/acq), and DLP per examination (DLP/exa) were recorded, and their mean, median, 25th and 75th percentiles compared. In 2008, an audit conducted in each department helped to optimise doses. In 2009 and 2010, two further surveys evaluated the audit's impact on the dose delivered. Between 2007 and 2009, DLP/exa significantly decreased by 32-69 % for all regions (P < 0.001) except the lumbar spine (5 %, P = 0.455). Between 2009 and 2010, DLP/exa significantly decreased by 13-18 % for sinus, cervical and lumbar spine (P ranging from 0.016 to less than 0.001). Between 2007 and 2010, DLP/exa significantly decreased for all regions (18-75 %, P < 0.001). Collective dose decreased by 30 % and the 75th percentile (diagnostic reference level, DRL) by 20-78 %. The audit process resulted in long-lasting dose reduction, with DRLs reduced by 20-78 %, mean DLP/examination by 18-75 %, and collective dose by 30 %. (orig.)

  9. Accuracy of hydro-multidetector row CT in the local T staging of oesophageal cancer compared to postoperative histopathological results

    To evaluate the accuracy of multidetector computed tomography with water filling (Hydro-MDCT) in the T-staging of patients with oesophageal cancer. There were 131 consecutive patients who were preoperatively and prospectively examined in the prone position on arterial phase contrast-enhanced MDCT, after ingestion of 1,000-1,500 ml tap water and effervescent granules. Two readers staged the local tumour growth (T-staging) independently. They assessed tumour location, size, presence of stenosis, and morphology of the outer border of the oesophageal wall and perioesophageal fat planes on CT. CT findings were compared with histopathological results from resected specimens. Data were analyzed using the SPSS statistical package. Both readers obtained a high sensitivity of 95% and a high positive predictive value of 96%. Accurate local staging was achieved in 76.3% and 68.7% for readers 1 and 2, respectively. Inter-reader agreement was excellent (weighted κ value of 0.93 and un-weighted κ of 0.89). Using the hydro-technique and applying specific assessment criteria, MDCT appears to be an accurate, non-invasive diagnostic tool for local tumour staging of oesophageal cancer. (orig.)

  10. Role of Multidetector CT in Evaluation of Acute Chest Pain: Non-Cardiac Vascular and Pulmonary Causes

    Rania S Sayed *, Hisham M Mansour **, Mohammad H Khaleel ***, Sherif H Abo Gamra ** and Merhan A Nasr

    2013-04-01

    Full Text Available Background: Triage of patients with acute chest pain is one of the most important issues currently facing physicians in the emergency department. Acute chest pain may be a symptom of a number of serious conditions and is generally considered a medical emergency. The causes of acute chest pain range from non-serious to life threatening. A rapid, accurate and cost-effective approach for the evaluation of emergency department patients with chest pain is needed. Aim of the work: This work aims to emphasize the role of multidetector CT in assessment of non-cardiac vascular and pulmonary causes of acute chest pain.Method: The studied group included 89 patients (59 men and 30 women presented by acute chest pain. All patients were subjected to MDCT and/or MDCT angiography using a Toshiba 64 detectors CT scanner. Results: The high spatial resolution and relatively non-invasive nature make MSCT angiography a strong and serious competitor to established vascular imaging techniques. Having the additional ability to simultaneously acquire information on other organs, which enables the early diagnosis of complications. Conclusion: Continued technical improvements in acquisition speed and spatial resolution of computed tomography images, and development of more efficient image reconstruction algorithms which reduce patient exposure to radiation and contrast result in increased popularity of MDCT.

  11. Cardiac Multi-detector CT Segmentation Based on Multiscale Directional Edge Detector and 3D Level Set.

    Antunes, Sofia; Esposito, Antonio; Palmisano, Anna; Colantoni, Caterina; Cerutti, Sergio; Rizzo, Giovanna

    2016-05-01

    Extraction of the cardiac surfaces of interest from multi-detector computed tomographic (MDCT) data is a pre-requisite step for cardiac analysis, as well as for image guidance procedures. Most of the existing methods need manual corrections, which is time-consuming. We present a fully automatic segmentation technique for the extraction of the right ventricle, left ventricular endocardium and epicardium from MDCT images. The method consists in a 3D level set surface evolution approach coupled to a new stopping function based on a multiscale directional second derivative Gaussian filter, which is able to stop propagation precisely on the real boundary of the structures of interest. We validated the segmentation method on 18 MDCT volumes from healthy and pathologic subjects using manual segmentation performed by a team of expert radiologists as gold standard. Segmentation errors were assessed for each structure resulting in a surface-to-surface mean error below 0.5 mm and a percentage of surface distance with errors less than 1 mm above 80%. Moreover, in comparison to other segmentation approaches, already proposed in previous work, our method presented an improved accuracy (with surface distance errors less than 1 mm increased of 8-20% for all structures). The obtained results suggest that our approach is accurate and effective for the segmentation of ventricular cavities and myocardium from MDCT images. PMID:26319010

  12. Radiation exposure in multidetector CT: Dose comparison between late 1990s and early 2010's in Korea

    The effective dose under ordinary clinical computed tomography (CT) protocols using three kinds of 64-channel and a 40-channel CT ranged from 0.6 to 15.5 mSv in early 2010's. And the organ dose ranged from 1.6 to 130.4 mGy: orbital and brain doses for brain stroke CT were the highest. For the comparison of the effective dose between late 1990s and early 2010's, multidetector CT (MDCT) for high-resolution lung CT was 2.4 times higher than that of single-detector CT (SDCT) and the ratio was the highest. However, the effective dose at MDCT was 20 % lower than that of SDCT in chest CT due to applying dose-saving techniques. In organ dose comparisons, high-resolution lung CT at MDCT was 3.5-4.5 times higher than that of SDCT, and showed 1.1-1.5 times higher than that of SDCT in the head and chest CT. For the abdomen CT, the primary organ dose at MDCT was ∼30 % lower than that of SDCT. (authors)

  13. Multidetector CT and MRI of ostial atresia of the coronary sinus, associated collateral venous pathways and cardiac anomalies

    Aim: To analyse the multidetector computed tomography (MDCT) and magnetic resonance imaging (MRI) findings in patients with atresia of the coronary sinus orifice (CSA). Materials and methods: MDCT findings of 15 consecutive adult patients with CSAs were retrospectively analysed. The patients underwent contrast-enhanced electrocardiography-gated MDCT (n = 13) or both CT and MRI (n = 2). Results: The mean size of the coronary sinus (CS) was 14.2 mm (range 5.5–24 mm) and 11 patients (73.3%) showed CS dilatation (diameter ≥12 mm). The mean length of the atretic CS segment was 2.9 mm (range 0–8 mm). Different forms of venous collateral pathways were observed in the CSA patients. Nine (60%) of the 15 CSA patients had communication between the right atrium (RA; n = 6) or LA (n = 5) and CS via intraseptal veins; six patients (40%) had persistent left superior caval veins; communications were also observed between the CS and RA (n = 4) or LA (n = 4); two patients had collateral venous pathways between dilated cardiac veins with RA; two patients had unroofing of the CS as outlet channels. Nine patients (60%) had cardiac anomalies: coronary artery fistula to the pulmonary artery (n = 6) or left ventricular base and CS (n = 1), atrial septal defects (n = 2), and a ventricular septal defect (n = 1). Conclusion: CSA patients have venous collateral pathways and a high incidence of associated cardiovascular anomalies such as coronary artery fistulae and atrial septal defects.

  14. Multidetector CT radiation dose optimisation in adults: short- and long-term effects of a clinical audit

    Tack, Denis [EpiCURA Hospital, Clinique Louis Caty, Department of Radiology, Baudour (Belgium); Jahnen, Andreas; Kohler, Sarah [CRP Henri Tudor, Luxembourg (Luxembourg); Harpes, Nico; Back, Carlo [Ministry of Health, Department of Radiation Protection, Luxembourg (Luxembourg); Maertelaer, Viviane de [Universite libre de Bruxelles, Institut de Recherche Interdisciplinaire en Biologie Humaine et Moleculaire and SBIM, Statistical Unit, Brussels (Belgium); Gevenois, Pierre Alain [Hopital Erasme, Department of Radiology, Brussels (Belgium)

    2014-01-15

    To report short- and long-term effects of an audit process intended to optimise the radiation dose from multidetector row computed tomography (MDCT). A survey of radiation dose from all eight MDCT departments in the state of Luxembourg performed in 2007 served as baseline, and involved the most frequently imaged regions (head, sinus, cervical spine, thorax, abdomen, and lumbar spine). CT dose index volume (CTDIvol), dose-length product per acquisition (DLP/acq), and DLP per examination (DLP/exa) were recorded, and their mean, median, 25th and 75th percentiles compared. In 2008, an audit conducted in each department helped to optimise doses. In 2009 and 2010, two further surveys evaluated the audit's impact on the dose delivered. Between 2007 and 2009, DLP/exa significantly decreased by 32-69 % for all regions (P < 0.001) except the lumbar spine (5 %, P = 0.455). Between 2009 and 2010, DLP/exa significantly decreased by 13-18 % for sinus, cervical and lumbar spine (P ranging from 0.016 to less than 0.001). Between 2007 and 2010, DLP/exa significantly decreased for all regions (18-75 %, P < 0.001). Collective dose decreased by 30 % and the 75th percentile (diagnostic reference level, DRL) by 20-78 %. The audit process resulted in long-lasting dose reduction, with DRLs reduced by 20-78 %, mean DLP/examination by 18-75 %, and collective dose by 30 %. (orig.)

  15. The effects of emphysema on airway disease: Correlations between multi-detector CT and pulmonary function tests in smokers

    Yahaba, Misuzu, E-mail: mis_misuzu@yahoo.co.jp; Kawata, Naoko, E-mail: chumito_03@yahoo.co.jp; Iesato, Ken, E-mail: iesato_k@yahoo.co.jp; Matsuura, Yukiko, E-mail: matsuyuki_future@yahoo.co.jp; Sugiura, Toshihiko, E-mail: sugiura@js3.so-net.ne.jp; Kasai, Hajime, E-mail: daikasai6075@yahoo.co.jp; Sakurai, Yoriko, E-mail: yoliri@nifty.com; Terada, Jiro, E-mail: jirotera@chiba-u.jp; Sakao, Seiichiro, E-mail: sakao@faculty.chiba-u.jp; Tada, Yuji, E-mail: ytada@faculty.chiba-u.jp; Tanabe, Nobuhiro, E-mail: ntanabe@faculty.chiba-u.jp; Tatsumi, Koichiro, E-mail: tatsumi@faculty.chiba-u.jp

    2014-06-15

    Background: Chronic obstructive pulmonary disease (COPD) is characterized by airflow limitation caused by emphysema and small airway narrowing. Quantitative evaluation of airway dimensions by multi-detector computed tomography (MDCT) has revealed a correlation between airway dimension and airflow limitation. However, the effect of emphysema on this correlation is unclear. Objective: The goal of this study was to determine whether emphysematous changes alter the relationships between airflow limitation and airway dimensions as measured by inspiratory and expiratory MDCT. Methods: Ninety-one subjects underwent inspiratory and expiratory MDCT. Images were evaluated for mean airway luminal area (Ai), wall area percentage (WA%) from the third to the fifth generation of three bronchi (B1, B5, B8) in the right lung, and low attenuation volume percent (LAV%). Correlations between each airway index and airflow limitation were determined for each patient and compared between patients with and without evidence of emphysema. Results: In patients without emphysema, Ai and WA% from both the inspiratory and expiratory scans were significantly correlated with FEV{sub 1.} No correlation was detected in patients with emphysema. In addition, emphysematous COPD patients with GOLD stage 1 or 2 disease had significantly lower changes in B8 Ai than non-emphysematous patients. Conclusions: A significant correlation exists between airway parameters and FEV{sub 1} in patients without emphysema. Emphysema may influence airway dimensions even in patients with mild to moderate COPD.

  16. A clinical algorithm for the assessment of pancreatic lesions: utilization of 16- and 64-section multidetector CT and endoscopic ultrasound

    Rafique, A. [Department of Radiology, Addenbrookes NHS Trust, Cambridge (United Kingdom)], E-mail: akkib1@gmail.com; Freeman, S.; Carroll, N. [Department of Radiology, Addenbrookes NHS Trust, Cambridge (United Kingdom)

    2007-12-15

    Pancreatic masses may be solid or cystic, benign or malignant, and their characterization can often be difficult as there is considerable overlap in their imaging features. Multidetector computed tomography (MDCT) with multiplanar reconstructions offers improved resolution and optimum visualization of the peripancreatic vasculature, which has improved the accuracy in predicting surgical resectability. Endoscopic ultrasound (EUS) is valuable in the detection of tumours not identified on CT. It is also accurate in identifying vascular involvement, which complements MDCT in predicting resectability. In cases of diagnostic uncertainty, EUS-guided fine-needle aspiration (FNA) can be used to obtain tissue samples from solid lesions and fluid aspirates from cystic lesions, allowing histological, cytological, and biochemical analysis to determine the nature of the lesion. This article focuses on the MDCT and EUS appearances of common pancreatic malignancies, highlighting their relative advantages and their complementary role in detecting and characterizing pancreatic masses. A clinical algorithm for the assessment of pancreatic malignancy, as practised in our institution, is outlined.

  17. Accuracy of hydro-multidetector row CT in the local T staging of oesophageal cancer compared to postoperative histopathological results

    Ba-Ssalamah, Ahmed; Matzek, Wolfgang; Baroud, Susanne; Bastati, Nina; Weber, Michael; Herold, Christian J. [Medical University of Vienna, Department of Radiology, Vienna (Austria); Zacherl, Johannes; Schoppmann, Sebastian F. [Medical University of Vienna, Department of Radiology, Vienna (Austria); Medical University of Vienna, Department of Surgery, Vienna (Austria); Hejna, Michael [Medical University of Vienna, Department of Radiology, Vienna (Austria); Medical University of Vienna, Department of Oncology, Vienna (Austria); Wrba, Fritz [Medical University of Vienna, Department of Radiology, Vienna (Austria); Medical University of Vienna, Department of Pathology, Vienna (Austria); Gore, Richard M. [University of Chicago Pritzker School of Medicine, Department of Radiology, Chicago, IL (United States)

    2011-11-15

    To evaluate the accuracy of multidetector computed tomography with water filling (Hydro-MDCT) in the T-staging of patients with oesophageal cancer. There were 131 consecutive patients who were preoperatively and prospectively examined in the prone position on arterial phase contrast-enhanced MDCT, after ingestion of 1,000-1,500 ml tap water and effervescent granules. Two readers staged the local tumour growth (T-staging) independently. They assessed tumour location, size, presence of stenosis, and morphology of the outer border of the oesophageal wall and perioesophageal fat planes on CT. CT findings were compared with histopathological results from resected specimens. Data were analyzed using the SPSS statistical package. Both readers obtained a high sensitivity of 95% and a high positive predictive value of 96%. Accurate local staging was achieved in 76.3% and 68.7% for readers 1 and 2, respectively. Inter-reader agreement was excellent (weighted {kappa} value of 0.93 and un-weighted {kappa} of 0.89). Using the hydro-technique and applying specific assessment criteria, MDCT appears to be an accurate, non-invasive diagnostic tool for local tumour staging of oesophageal cancer. (orig.)

  18. Accuracy of hepatocellular carcinoma detection on multidetector CT in a transplant liver population with explant liver correlation

    Addley, H.C., E-mail: helenclareaddley@hotmail.co.u [Department of Radiology, Addenbrooke' s Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); Griffin, N.; Shaw, A.S.; Mannelli, L. [Department of Radiology, Addenbrooke' s Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); Parker, R.A. [Department of Medical Statistics, Addenbrooke' s Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); Aitken, S.; Wood, H. [Department of Radiology, Addenbrooke' s Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); Davies, S. [Department of Histopathology, Addenbrooke' s Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); Alexander, G.J. [Department of Hepatology, Addenbrooke' s Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); Lomas, D.J. [Department of Radiology, Addenbrooke' s Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom)

    2011-04-15

    Aim: To evaluate the diagnostic accuracy of multidetector computed tomography (MDCT) for hepatocellular carcinoma (HCC) in cirrhotic patients undergoing liver transplantation. Secondary aims were to examine the effect of radiologist experience and lesion size on diagnostic accuracy. Materials and methods: Thirty-nine patients (72% male with a mean age of 56.5 years) underwent liver transplantation following preoperative triple-phase MDCT examination of the liver. MDCT examinations were retrospectively independently reviewed by three radiologists for the presence and location of suspected HCCs, with the diagnostic confidence recorded using a five-point confidence scale. MDCT examinations were compared with explant specimens for histopathological correlation. Results: Histopathological results demonstrated 46 HCCs in 29 of the 39 patients. Analysis demonstrated a sensitivity of 65-75% and specificity of 47-88% for detection of HCC lesions. The sensitivity dropped to 48-57% for lesions of size {<=}20 mm. As the diagnostic confidence increased, there was a further decrease in the sensitivity (4-26%). The radiologist with the greatest number of years experience was found to have a significantly higher accuracy of detection of HCC lesions compared with the least experienced radiologist. Conclusion: Larger lesion size of HCC and greater number of years experience of the radiologist resulted in significantly higher accuracy of HCC lesion detection. The overall sensitivity and specificity results for MDCT detection of HCC are comparable to previous helical CT imaging.

  19. Accuracy of hepatocellular carcinoma detection on multidetector CT in a transplant liver population with explant liver correlation

    Aim: To evaluate the diagnostic accuracy of multidetector computed tomography (MDCT) for hepatocellular carcinoma (HCC) in cirrhotic patients undergoing liver transplantation. Secondary aims were to examine the effect of radiologist experience and lesion size on diagnostic accuracy. Materials and methods: Thirty-nine patients (72% male with a mean age of 56.5 years) underwent liver transplantation following preoperative triple-phase MDCT examination of the liver. MDCT examinations were retrospectively independently reviewed by three radiologists for the presence and location of suspected HCCs, with the diagnostic confidence recorded using a five-point confidence scale. MDCT examinations were compared with explant specimens for histopathological correlation. Results: Histopathological results demonstrated 46 HCCs in 29 of the 39 patients. Analysis demonstrated a sensitivity of 65-75% and specificity of 47-88% for detection of HCC lesions. The sensitivity dropped to 48-57% for lesions of size ≤20 mm. As the diagnostic confidence increased, there was a further decrease in the sensitivity (4-26%). The radiologist with the greatest number of years experience was found to have a significantly higher accuracy of detection of HCC lesions compared with the least experienced radiologist. Conclusion: Larger lesion size of HCC and greater number of years experience of the radiologist resulted in significantly higher accuracy of HCC lesion detection. The overall sensitivity and specificity results for MDCT detection of HCC are comparable to previous helical CT imaging.

  20. The effects of emphysema on airway disease: Correlations between multi-detector CT and pulmonary function tests in smokers

    Background: Chronic obstructive pulmonary disease (COPD) is characterized by airflow limitation caused by emphysema and small airway narrowing. Quantitative evaluation of airway dimensions by multi-detector computed tomography (MDCT) has revealed a correlation between airway dimension and airflow limitation. However, the effect of emphysema on this correlation is unclear. Objective: The goal of this study was to determine whether emphysematous changes alter the relationships between airflow limitation and airway dimensions as measured by inspiratory and expiratory MDCT. Methods: Ninety-one subjects underwent inspiratory and expiratory MDCT. Images were evaluated for mean airway luminal area (Ai), wall area percentage (WA%) from the third to the fifth generation of three bronchi (B1, B5, B8) in the right lung, and low attenuation volume percent (LAV%). Correlations between each airway index and airflow limitation were determined for each patient and compared between patients with and without evidence of emphysema. Results: In patients without emphysema, Ai and WA% from both the inspiratory and expiratory scans were significantly correlated with FEV1. No correlation was detected in patients with emphysema. In addition, emphysematous COPD patients with GOLD stage 1 or 2 disease had significantly lower changes in B8 Ai than non-emphysematous patients. Conclusions: A significant correlation exists between airway parameters and FEV1 in patients without emphysema. Emphysema may influence airway dimensions even in patients with mild to moderate COPD

  1. Preoperative Gross Classification of Gastric Adenocarcinoma: Comparison of Double Contrast-Enhanced Ultrasound and Multi-Detector Row CT.

    Yan, Caoxin; Bao, Xiaofeng; Shentu, Weihui; Chen, Jian; Liu, Chunmei; Ye, Qin; Wang, Liuhong; Tan, Yangbin; Huang, Pintong

    2016-07-01

    The aim of this study was to compare the accuracy of multi-detector computed tomography (MDCT) with double contrast-enhanced ultrasound (DCEUS), in which intravenous microbubbles are used alongside oral contrast-enhanced ultrasound, in determining the gross classification of patients with gastric carcinoma (GC). Altogether, 239 patients with GC proved by histology after endoscopic biopsy were included in this study. DCEUS and MDCT were performed pre-operatively. The diagnostic accuracies of DCEUS and MDCT in determining the gross classification were calculated and compared. The overall accuracy of DCEUS in determining the gross appearance of GC was higher than that of MDCT (84.9% vs. 79.9%, p cancer (χ(2), p = 0.323 for Borrmann type I, p = 0.141 for Borrmann type IV). The accuracy of DCEUS for early GC and Borrmann II and III classifications of GC was higher than that of MDCT (χ(2), p = 0.000 for all). DCEUS may be regarded as a valuable complementary tool to MDCT in determining the gross appearance of gastric adenocarcinoma pre-operatively. PMID:27072076

  2. Multidetector CT imaging of mechanical prosthetic heart valves: quantification of artifacts with a pulsatile in-vitro model

    Symersky, Petr [Onze Lieve Vrouwe Gasthuis, Department of Cardiothoracic Surgery, Oosterpark 9, P.O box 95500, Amsterdam (Netherlands); Academic Medical Center, Department of Cardiothoracic Surgery, Amsterdam (Netherlands); Budde, Ricardo P.J. [University Medical Center, Department of Radiology, Utrecht (Netherlands); Westers, Paul [Julius Center for Health Sciences and Primary Care, Department of Biostatistics, Utrecht (Netherlands); Mol, Bas A.J.M. de [Academic Medical Center, Department of Cardiothoracic Surgery, Amsterdam (Netherlands); University of Technology Eindhoven, Department of Biomedical Engineering, Eindhoven (Netherlands); Prokop, Mathias [Radboud University Nijmegen Medical Center, Department of Radiology, Nijmegen (Netherlands)

    2011-10-15

    Multidetector computed tomography (MDCT) can detect the cause of prosthetic heart valve (PHV) dysfunction but is hampered by valve-induced artifacts. We quantified artifacts of four PHV using a pulsatile in-vitro model and assessed the relation to leaflet motion and valve design. A Medtronic Hall tilting disc (MH), and Carbomedics (CM), St Jude (SJM), and ON-X bileaflet valves underwent CT in an in-vitro model using retrospective gating with a 64 detector CT system in stationary and pulsatile conditions. Artifacts and radiopaque component volumes were quantified with thresholds based on surrounding structures and valvular components. Hypodense artifacts volumes (mm{sup 3}) were 1,029 {+-} 147, 535 {+-} 53, 371 {+-} 16, and 366 {+-} 18 for the SJM, MH, CM and ON-X valves (p < 0.001 except for the latter two valves p = 0.43). Hyperdense artifact volumes were 3,546 {+-} 141, 2,387 {+-} 103, 2,003 {+-} 102, and 3,033 {+-} 31 for the SJM, MH, CM and ON-X valve, respectively (all differences p < 0.001). Leaflet motion affected hypodense (F = 41.5, p < 0.001) and hyperdense artifacts (F = 53.7, p < 0.001). Closed and moving leaflets were associated with the least and the most artifacts respectively (p < 0.001, both artifact types). Both valve design and leaflet motion affect PHV-induced artifacts. Best imaging results may be expected for the CM valve during phases in which the leaflets are closed. (orig.)

  3. Volumetric Measurements of Lung Nodules with Multi-Detector Row CT: Effect of Changes in Lung Volume

    To evaluate how changes in lung volume affect volumetric measurements of lung nodules using a multi-detector row CT. Ten subjects with asthma or chronic bronchitis who had one or more lung nodules were included. For each subject, two sets of CT images were obtained at inspiration and at expiration. A total of 33 nodules (23 nodules ≥3 mm) were identified and their volume measured using a semiautomatic volume measurement program. Differences between nodule volume on inspiration and expiration were compared using the paired t-test. Percent differences, between on inspiration and expiration, in nodule attenuation, total lung volume, whole lung attenuation, and regional lung attenuation, were computed and compared with percent difference in nodule volume determined by linear correlation analysis. The difference in nodule volume observed between inspiration and expiration was significant (p < 0.01); the mean percent difference in lung nodule volume was 23.1% for all nodules and for nodules ≥3 mm. The volume of nodules was measured to be larger on expiration CT than on inspiration CT (28 out of 33 nodules; 19 out of 23 nodules ≥3 mm). A statistically significant correlation was found between the percent difference of lung nodule volume and lung volume or regional lung attenuation (p < 0.05) for nodules ≥3 mm. Volumetric measurements of pulmonary nodules were significantly affected by changes in lung volume. The variability in this respiration-related measurement should be considered to determine whether growth has occurred in a lung nodule

  4. Development of a charged particle multidetector and application to physics at the Vivitron accelerator

    The charged particle multidetector ICARE is an apparatus designed for the Vivitron accelerator, with the aim to study both heavy ions reaction mechanisms and the structure of the nuclei. It will be able to work independently with its own electronic and acquisition system as well as in association with other types of multidetectors (Eurogam, Demon, ...). The development of ICARE is based on compactness and modularity criteria and takes into account the expected multiplicities and energies of the particles to be detected. It is composed of 48 compact telescopes of low energy threshold, 8 of them being heavy ion telescopes (Z 147Gd superdeformed states of highest angular momenta. In the gamma ray spectra detected by the Eurogam array in coincidence with fission fragments, a positive contribution corresponding to energy differences are observed, which are consistent with the emission by superdeformed states. (from author) 64 figs., 12 tabs., 91 refs

  5. Monte Carlo simulations with MENATE program in order to determine the characteristics of neutron multidetector

    The neutron multidetector consists of 81 detectors, made of 4x4x12 cmc BC-400 crystals mounted on XP2972 phototubes. This detector placed in the forward direction at 138 cm from the target, was used to detect the correlated neutrons in the fusion of Li11 halo nuclei with Si targets. To verify the criterion for selecting the true coincidences against cross-talk ( a spurious effect in which the same neutron is registered by two or more detectors) and to establish the optimal distance between adjacent detectors, the program MENATE ( written by P.Desesquelles, IPN - Orsay) was used to generate Monte Carlo neutrons and their interactions in multidetector. The results were analysed with PAW (from CERN Library). (authors)

  6. Computer

    Atkinson, Paul

    2011-01-01

    The pixelated rectangle we spend most of our day staring at in silence is not the television as many long feared, but the computer-the ubiquitous portal of work and personal lives. At this point, the computer is almost so common we don't notice it in our view. It's difficult to envision that not that long ago it was a gigantic, room-sized structure only to be accessed by a few inspiring as much awe and respect as fear and mystery. Now that the machine has decreased in size and increased in popular use, the computer has become a prosaic appliance, little-more noted than a toaster. These dramati

  7. Multi-detector CT/CT angiogram assessment of acute pancreatic graft dysfunction

    Simultaneous pancreatic-kidney transplantation is the definitive treatment for patients with type 1 diabetes mellitus and renal failure. Pancreatic graft failure is an important postoperative complication and most commonly occurs as a result of pancreatitis, graft thrombosis or rejection. Distinguishing between these causes is necessary to determine timely, appropriate management and thereby potentially minimising graft loss. Multi-detector CT imaging may be used to identify the cause of pancreatic graft dysfunction when renal function is not markedly impaired.

  8. Diagnosis of arterioportal shunts in cases of hepatocellular carcinoma using multidetector CT: Impact on clinical management

    Ahmed Mostafa Mohamed; Mohamed El Gharib A. Elmaaty; Ayman Mohamed Ibrahim; Waleed Hamed; Amr Hafez El Fouly

    2014-01-01

    Purpose: To study the ability of multidetector CT (MDCT) to diagnose arterioportal shunts (APS) associated with hepatocellular carcinoma (HCC) and its impact on further management of the patient. Patients and methods: 252 Patients with HCC were examined by triphasic MDCT scanning. Images were analyzed for the presence, locations, types and degrees of APS, being with or without thrombosis. Digital subtraction angiographies (DSA) were performed for 22 patients as a part of further therapeuti...

  9. Nuclear structure at high spin using multidetector gamma array and ancillary detectors

    S Muralithar

    2014-04-01

    A multidetector gamma array (GDA), for studying nuclear structure was built with ancillary devices namely gamma multiplicity filter and charged particle detector array. This facility was designed for in-beam gamma spectroscopy measurements in fusion evaporation reactions at Inter-University Accelerator Centre, New Delhi. Description of the facility and in-beam performance with two experimental studies done are presented. This array was used in a number of nuclear spectroscopic and reaction investigations.

  10. Measurement of lumbar bone density by biphotonic absorptiometry. Contribution of a multidetector system

    The in-vitro and in-vivo performances of a biphotonic absorptiometer with multidetector (ORIS ODC 200/SOPHA Medical France r) were compared with those of a first generation device (LAb 22a/NOVO Denmark) with a single detector. The reproducibility of both devices was tested in-vitro on a hydroxyapatite powder ghost template and a human spine enclosed in polymethyl-metacrylate; the best variation coefficients, for results in grams per cm2, are 2.11 and 1.35 p. cent for the hydroxyapatite powder and 1 and 1.36 p. cent for the spine with the single detector device and the multidetector apparatus, respectively. Influence of the soft tissues thickness measured with an aluminum tube immersed under increasing water depths (5 to 20 cm), shows decreased values in g/cm2 of 0.2 p. cent per cm of water with the multidetector apparatus, and 0.67 p. cent; for the single detector device. In vivo, the reproducibility was evaluated on 5 control patients, 3 with repositioning (CV: ORIS = 1.97 p. cent; CV: NOVO = 2.59 p. cent), and two without repositioning (CV: ORIS = 0.26 p. cent; CV: NOVO = 0.60 p. cent). Besides, the correlation between the values obtained with both devices in 62 patients is highly significant (9 = 0.95), with values with the multidetector apparatus exceeding by 13.7 p. cent those obtained with the single detector device. This excellent correlation permits to adjust the results and especially the normal reference values from one apparatus to the other

  11. The role of Multidetector CT in the evaluation of the left atrium and pulmonary veins anatomy before and after radio-frequency catheter ablation for atrial fibrillation. Preliminary results and work in progress.Technical note

    Radio-frequency catheter ablation (RFCA) of the distal pulmonary veins is increasingly being used to treat recurrent or refractory atrial fibrillation that doesn't respond to pharmacologic therapy or cardioversion. Successful RFCA of atrial al fibrillation depends on the pre-procedural understanding of the complex anatomy of the distal pulmonary veins and the left atrium. Aim of this parer is to describe the technical main features that characterise the multidetector helical computed tomography in the evaluation of this anatomic region before and after RFCA procedure. The 3D post-processing techniques useful for pre-RFCA planning are straightforward

  12. COMPUTING

    I. Fisk

    2010-01-01

    Introduction It has been a very active quarter in Computing with interesting progress in all areas. The activity level at the computing facilities, driven by both organised processing from data operations and user analysis, has been steadily increasing. The large-scale production of simulated events that has been progressing throughout the fall is wrapping-up and reprocessing with pile-up will continue. A large reprocessing of all the proton-proton data has just been released and another will follow shortly. The number of analysis jobs by users each day, that was already hitting the computing model expectations at the time of ICHEP, is now 33% higher. We are expecting a busy holiday break to ensure samples are ready in time for the winter conferences. Heavy Ion An activity that is still in progress is computing for the heavy-ion program. The heavy-ion events are collected without zero suppression, so the event size is much large at roughly 11 MB per event of RAW. The central collisions are more complex and...

  13. COMPUTING

    M. Kasemann P. McBride Edited by M-C. Sawley with contributions from: P. Kreuzer D. Bonacorsi S. Belforte F. Wuerthwein L. Bauerdick K. Lassila-Perini M-C. Sawley

    Introduction More than seventy CMS collaborators attended the Computing and Offline Workshop in San Diego, California, April 20-24th to discuss the state of readiness of software and computing for collisions. Focus and priority were given to preparations for data taking and providing room for ample dialog between groups involved in Commissioning, Data Operations, Analysis and MC Production. Throughout the workshop, aspects of software, operating procedures and issues addressing all parts of the computing model were discussed. Plans for the CMS participation in STEP’09, the combined scale testing for all four experiments due in June 2009, were refined. The article in CMS Times by Frank Wuerthwein gave a good recap of the highly collaborative atmosphere of the workshop. Many thanks to UCSD and to the organizers for taking care of this workshop, which resulted in a long list of action items and was definitely a success. A considerable amount of effort and care is invested in the estimate of the comput...

  14. Congenital anomalies of coronary arteries: Diagnosis with 64 slice multidetector CT

    Objective: Congenital coronary artery anomalies are generally incidental, uncommon and asymptomatic. Some can cause severe potentially life threatening symptoms. The common mode of studying the coronary arteries is Conventional Coronary Angiogram. ECG-gated-multidetector CT is a non invasive modality. The objective of our study was to identify rare congenital coronary artery anomalies and discuss their clinical significance. Material and methods: A total number of 900 MDCT coronary angiograms were carried out at our institution between the period of April 2006 and October 2010. Patients with coronary artery anomaly constituted the subject of study. Results: The incidence of anomalous anatomical origin and course of the coronary arteries in our study was 1.55%. Hemodynamical significance was seen in five patients. 3 cases of single coronary artery originating from right coronary sinus were seen. 1 case of anomalous left coronary artery arising from main pulmonary artery was seen. 4 cases of anomalous RCA arising from left aortic cusp, 6 cases of absent LMCA with separate origin of LAD and LCX were seen. Conclusion: Multidetector row CT is a noninvasive modality in cardiac imaging. It provides superior resolution of coronary tree and its variant. No projectional vascular overlap is seen. Various postprocessing techniques outclass catheter angiography imaging. Definition of ostia and proximal course of the coronary arteries by Multidetector CT is better than catheter angiography.