  1. High-resolution motion compensated MRA in patients with congenital heart disease using extracellular contrast agent at 3 Tesla

    Dabir Darius

    2012-10-01

    Full Text Available Abstract Background Using first-pass MRA (FP-MRA spatial resolution is limited by breath-hold duration. In addition, image quality may be hampered by respiratory and cardiac motion artefacts. In order to overcome these limitations an ECG- and navigator-gated high-resolution-MRA sequence (HR-MRA with slow infusion of extracellular contrast agent was implemented at 3 Tesla for the assessment of congenital heart disease and compared to standard first-pass-MRA (FP-MRA. Methods 34 patients (median age: 13 years with congenital heart disease (CHD were prospectively examined on a 3 Tesla system. The CMR-protocol comprised functional imaging, FP- and HR-MRA, and viability imaging. After the acquisition of the FP-MRA sequence using a single dose of extracellular contrast agent the motion compensated HR-MRA sequence with isotropic resolution was acquired while injecting the second single dose, utilizing the timeframe before viability imaging. Qualitative scores for image quality (two independent reviewers as well as quantitative measurements of vessel sharpness and relative contrast were compared using the Wilcoxon signed-rank test. Quantitative measurements of vessel diameters were compared using the Bland-Altman test. Results The mean image quality score revealed significantly better image quality of the HR-MRA sequence compared to the FP-MRA sequence in all vessels of interest (ascending aorta (AA, left pulmonary artery (LPA, left superior pulmonary vein (LSPV, coronary sinus (CS, and coronary ostia (CO; all p  Conclusions An ECG- and navigator-gated HR-MRA-protocol with infusion of extracellular contrast agent at 3 Tesla is feasible. HR-MRA delivers significantly better image quality and vessel sharpness compared to FP-MRA. It may be integrated into a standard CMR-protocol for patients with CHD without the need for additional contrast agent injection and without any additional examination time.

  2. High resolution T{sub 2}{sup *}-weighted magnetic resonance imaging at 3 Tesla using PROPELLER-EPI

    Kraemer, Martin; Reichenbach, Juergen R. [Jena University Hospital (Germany). Medical Physics Group

    2014-09-01

    We report the application of PROPELLER-EPI for high resolution T{sub 2}{sup *}-weighted imaging with sub-millimeter in-plane resolution on a clinical 3 Tesla scanner. Periodically rotated blades of a long-axis PROPELLER-EPI sequence were acquired with fast gradient echo readout and acquisition matrix of 320 x 50 per blade. Images were reconstructed by using 2D-gridding, phase and geometric distortion correction and compensation of resonance frequency drifts that occurred during extended measurements. To characterize these resonance frequency offsets, short FID calibration measurements were added to the PROPELLER-EPI sequence. Functional PROPELLER-EPI was performed with volunteers using a simple block design of right handed finger tapping. Results indicate that PROPELLER-EPI can be employed for fast, high resolution T{sub 2}{sup *}-weighted imaging provided geometric distortions and possible resonance frequency drifts are properly corrected. Even small resonance frequency drifts below 10 Hz as well as non-corrected geometric distortions degraded image quality substantially. In the initial fMRI experiment image quality and signal-to-noise ratio was sufficient for obtaining high resolution functional activation maps. (orig.)

  3. High-Resolution Magnetic Resonance Imaging of Trabecular Bone in the Wrist at 3 Tesla: Initial Results

    Ludescher, B.; Martirosian, P.; Lenk, S.; Machann, J.; Dammann, F.; Schick, F.; Claussen, C.; Schlemmer, H. [Univ. Clinic, Tuebingen (Germany). Dept. of Diagnostic Radiology and Section on Experimental Radiology

    2005-05-01

    Purpose: To evaluate the feasibility of high-resolution magnetic resonance imaging (MRI) of trabecular bone of the wrist at 3 Tesla (3T) in vivo and to assess the potential benefit of the increased resolution for clinical assessment of structural changes in spongy bone. Material and Methods: High-resolution MRI of the wrist was performed with a whole-body 3T MR scanner using a dedicated circularly polarized transmit/receive wrist-coil. Two 3D-FISP sequences with a spatial resolution of 300x300x300 {mu}m{sup 3} in a measuring time of TA{approx}7:51 min, and 200x200x200 {mu}m{sup 3} in TA{approx}9:33 min were applied. Seven young healthy volunteers and three elderly subjects with suspected osteoporosis were examined. The signal-to-noise ratio (SNR) in the optimized setup at 3T was compared to measurements at 1.5T. Results: The images at 3T allow microscopic analysis of the bone structure at an isotropic spatial resolution of 200 {mu}m in examination times of <10 min. Differences in the structure of the spongy bone between normal and markedly osteoporotic subjects are well depicted. The SNR at 3T was found up to 16 times higher than at 1.5T applying unchanged imaging parameters. Conclusion: The proposed high-resolution MRI technique offers high potential in the diagnosis and follow-up of diseases with impaired bone structure of hand and/or wrist in clinical applications.

  4. High-resolution cine MRI with TGRAPPA for fast assessment of left ventricular function at 3 Tesla

    Purpose: To implement and evaluate the accuracy of multislice dual-breath hold cine MR for analysis of global systolic and diastolic left ventricular function at 3 T. Materials and methods: 25 patients referred to cardiac MR underwent cine imaging at 3 T (MAGNETOM Verio) using prospective triggered SSFP (TR 3.1 ms; TE 1.4 ms; FA 60°). Analysis of LV function was performed using a standard non-accelerated single-slice approach (STD) with multiple breath-holds and an accelerated multi-slice technique (TGRAPPA; R = 4) encompassing the ventricles with 5 slices/breath-hold. Parameters of spatial and temporal resolution were kept identical (pixel: 1.9 × 2.5 mm2; temporal resolution: 47 ms). Data of both acquisition techniques were analyzed by two readers using semiautomatic algorithms (syngoARGUS) with respect to EDV, ESV, EF, myocardial mass (MM), peak filling rate (PFR) and peak ejection rate (PER) including assessment of interobserver agreement. Results: Volumetric results of the TGRAPPA approach did not show significant differences to the STD approach for left ventricular ejection fraction (62.3 ± 10.6 vs. 61.0 ± 8.4, P = 0.2), end-diastolic volume (135.8 ± 47.5 vs. 130.8 ± 46.4, P = 0.07), endsystolic volume (53.0 ± 29.7 vs. 53.1 ± 32.7, P = 0.99) and myocardial mass (114.2 ± 32.5 vs. 114.6 ± 30.6, P = 0.9). Moreover, a comparison of peak ejection rate (601.3 ± 190.2 vs. 590.8 ± 218.2, P = 0.8) and peak filling rate (535.1 ± 191.2 vs. 535.4 ± 210.7, P = 0.99) did not reveal significant differences between the two groups. Limits in interobserver agreement were low for all systolic and diastolic parameters in both groups (P ≥ 0.05). Total acquisition time for STD was 273 ± 124 s and 34 ± 5 s for TGRAPPA (P ≤ 0.001). Evaluation time for standard and multislice approach was equal (10.8 ± 1.4 vs. 9.8 ± 2.1 min; P = 0.08)

  5. High-resolution cine MRI with TGRAPPA for fast assessment of left ventricular function at 3 Tesla

    Theisen, Daniel, E-mail: daniel.theisen@med.uni-muenchen.de [Department of Clinical Radiology, University Hospitals of Munich Grosshadern, Munich (Germany); Munich Heart Alliance, Munich (Germany); Sandner, Torleif A., E-mail: torleif.sandner@med.uni-muenchen.de [Department of Clinical Radiology, University Hospitals of Munich Grosshadern, Munich (Germany); Bamberg, Fabian, E-mail: fabian.bamberg@med.uni-muenchen.de [Department of Clinical Radiology, University Hospitals of Munich Grosshadern, Munich (Germany); Munich Heart Alliance, Munich (Germany); Bauner, Kerstin U., E-mail: kerstin.bauner@med.uni-muenchen.de [Department of Clinical Radiology, University Hospitals of Munich Grosshadern, Munich (Germany); Schwab, Felix, E-mail: felix.schwab@med.uni-muenchen.de [Department of Clinical Radiology, University Hospitals of Munich Grosshadern, Munich (Germany); Schwarz, Florian, E-mail: florian.schwarz@med.uni-muenchen.de [Department of Clinical Radiology, University Hospitals of Munich Grosshadern, Munich (Germany); Arnoldi, Elisabeth, E-mail: elisabeth.arnoldi@med.uni-muenchen.de [Department of Clinical Radiology, University Hospitals of Munich Grosshadern, Munich (Germany); Reiser, Maximilian F., E-mail: maximilian.reiser@med.uni-muenchen.de [Department of Clinical Radiology, University Hospitals of Munich Grosshadern, Munich (Germany); Munich Heart Alliance, Munich (Germany); Wintersperger, Bernd J., E-mail: bernd.wintersperger@med.uni-muenchen.de [Department of Clinical Radiology, University Hospitals of Munich Grosshadern, Munich (Germany); Department of Medical Imaging, University of Toronto, Toronto, Ontario (Canada)

    2013-05-15

    Purpose: To implement and evaluate the accuracy of multislice dual-breath hold cine MR for analysis of global systolic and diastolic left ventricular function at 3 T. Materials and methods: 25 patients referred to cardiac MR underwent cine imaging at 3 T (MAGNETOM Verio) using prospective triggered SSFP (TR 3.1 ms; TE 1.4 ms; FA 60°). Analysis of LV function was performed using a standard non-accelerated single-slice approach (STD) with multiple breath-holds and an accelerated multi-slice technique (TGRAPPA; R = 4) encompassing the ventricles with 5 slices/breath-hold. Parameters of spatial and temporal resolution were kept identical (pixel: 1.9 × 2.5 mm{sup 2}; temporal resolution: 47 ms). Data of both acquisition techniques were analyzed by two readers using semiautomatic algorithms (syngoARGUS) with respect to EDV, ESV, EF, myocardial mass (MM), peak filling rate (PFR) and peak ejection rate (PER) including assessment of interobserver agreement. Results: Volumetric results of the TGRAPPA approach did not show significant differences to the STD approach for left ventricular ejection fraction (62.3 ± 10.6 vs. 61.0 ± 8.4, P = 0.2), end-diastolic volume (135.8 ± 47.5 vs. 130.8 ± 46.4, P = 0.07), endsystolic volume (53.0 ± 29.7 vs. 53.1 ± 32.7, P = 0.99) and myocardial mass (114.2 ± 32.5 vs. 114.6 ± 30.6, P = 0.9). Moreover, a comparison of peak ejection rate (601.3 ± 190.2 vs. 590.8 ± 218.2, P = 0.8) and peak filling rate (535.1 ± 191.2 vs. 535.4 ± 210.7, P = 0.99) did not reveal significant differences between the two groups. Limits in interobserver agreement were low for all systolic and diastolic parameters in both groups (P ≥ 0.05). Total acquisition time for STD was 273 ± 124 s and 34 ± 5 s for TGRAPPA (P ≤ 0.001). Evaluation time for standard and multislice approach was equal (10.8 ± 1.4 vs. 9.8 ± 2.1 min; P = 0.08)

  6. Human brain diffusion tensor imaging at submillimeter isotropic resolution on a 3Tesla clinical MRI scanner.

    Chang, Hing-Chiu; Sundman, Mark; Petit, Laurent; Guhaniyogi, Shayan; Chu, Mei-Lan; Petty, Christopher; Song, Allen W; Chen, Nan-kuei

    2015-09-01

    The advantages of high-resolution diffusion tensor imaging (DTI) have been demonstrated in a recent post-mortem human brain study (Miller et al., NeuroImage 2011;57(1):167-181), showing that white matter fiber tracts can be much more accurately detected in data at a submillimeter isotropic resolution. To our knowledge, in vivo human brain DTI at a submillimeter isotropic resolution has not been routinely achieved yet because of the difficulty in simultaneously achieving high resolution and high signal-to-noise ratio (SNR) in DTI scans. Here we report a 3D multi-slab interleaved EPI acquisition integrated with multiplexed sensitivity encoded (MUSE) reconstruction, to achieve high-quality, high-SNR and submillimeter isotropic resolution (0.85×0.85×0.85mm(3)) in vivo human brain DTI on a 3Tesla clinical MRI scanner. In agreement with the previously reported post-mortem human brain DTI study, our in vivo data show that the structural connectivity networks of human brains can be mapped more accurately and completely with high-resolution DTI as compared with conventional DTI (e.g., 2×2×2mm(3)). PMID:26072250

  7. Impact of high resolution 3 tesla MR neurography (MRN) on diagnostic thinking and therapeutic patient management

    Chhabra, Avneesh [Southwestern Medical Center, Department of Radiology, Dallas, TX (United States); Johns Hopkins Hospital, Russell H. Morgan Department of Radiology and Radiological Science, Baltimore, MD (United States); Belzberg, Allan J. [Johns Hopkins University School of Medicine, Department of Neurosurgery, Baltimore, MD (United States); Rosson, Gedge D.; Shores, Jaimie T.; Deune, Gene [Johns Hopkins University School of Medicine, Department of Plastic Surgery, Baltimore, MD (United States); Thawait, Gaurav K.; Chalian, M.; Farahani, Sahar J.; Thawait, Shrey K. [Johns Hopkins Hospital, Russell H. Morgan Department of Radiology and Radiological Science, Baltimore, MD (United States); Hashemi, Shar [Dellon Institute, Towson, MD (United States); Subhawong, Ty K. [University of Miami Health System, Department of Radiology, Miami, FL (United States); Carrino, John A. [Weill Cornell Medical College, Hospital for Special Surgery, Department of Radiology and Imaging, New York, NY (United States)

    2016-05-15

    To evaluate the impact of magnetic resonance neurography (MRN) on diagnostic thinking and therapeutic choices in patients with suspected peripheral neuropathy. IRB approval was obtained for this HIPAA-compliant study. Questionnaires were administered to six surgeons regarding the diagnosis and treatment in 85 patients suspected of having peripheral neuropathy, before (pretest) and after (posttest) MRN. Multiple outcome measures related to diagnostic confidence and surgical decision-making were assessed. The final cohort included 81 patients (30 men and 51 women, age 47 ± 17 years). The following changes were observed from pretest to posttest questionnaires: 23 % in nerve involvement (P < 0.05), 48 % in degree of confidence of nerve involvement (P < 0.01), 27 % in grade of injury (P < 0.05), 33 % in differential diagnosis (P < 0.05), 63 % in degree of confidence in need for surgery (P < 0.001), 41 % in timing of surgery (P < 0.01), 30 % in approach to surgery (P < 0.05), 58 % in degree of confidence in approach to surgery (P < 0.001), 30 % in estimated length of surgery (P < 0.05) and 27 % in length of incision (P < 0.05). The dichotomous decision regarding surgical or nonsurgical treatment changed from pro to con in 17 %. MRN results significantly influenced the diagnostic thinking and therapeutic recommendations of peripheral nerve surgeons. circle In patients with peripheral neuropathy, MRN significantly impacts diagnostic thinking. (orig.)

  8. Magnetic resonance imaging of articular cartilage at 3 tesla

    Smooth motor function can be maintained by articular cartilage. When the cartilage is injured, edema occurs, and as degeneration progresses, the cartilage thins and the cartilage matrix decreases. Magnetic resonance (MR) imaging allows noninvasive evaluation of these changes. Fat suppression proton density- and T2-weighted imaging are useful in the morphologic evaluation of articular cartilage. High resolution, 3-tesla MR imaging provides more detailed evaluation. Biochemical information from T2 mapping, T1ρ mapping, and delayed gadolinium-enhanced MR imaging of cartilage (dGEMRIC) is useful for early diagnosis of cartilage injury and evaluation of cartilage repair. The role of MR imaging in evaluating articular cartilage will increase in the future aging society. (author)

  9. A Novel 16-Channel Receive Coil Array for Accelerated Upper Airway MRI at 3 Tesla

    Kim, Yoon-Chul; Hayes, Cecil E.; Narayanan, Shrikanth S.; Nayak, Krishna S.

    2010-01-01

    Upper airway MRI provides a non-invasive assessment of speech and swallowing disorders and sleep apnea. Recent work has demonstrated the value of high-resolution three-dimensional (3D) imaging and dynamic 2D imaging and the importance of further improvements in spatio-temporal resolution. The purpose of the study was to describe a novel 16-channel 3 Tesla receive coil that is highly sensitive to the human upper airway and investigate the performance of accelerated upper airway MRI with the co...

  10. Acute Posterior Ischemic Optic Neuropathy Mimicking Posterior Cerebral Artery Stroke Visualized by 3-Tesla MRI

    Tilman Menzel

    2012-11-01

    Full Text Available Acute ischemic lesions of the posterior optic nerve and optic tract can produce a variety of visual field defects. A 71-year-old woman presented with acute hemianopia, which led to rt-PA thrombolysis for suspected posterior cerebral artery ischemia. 3-Tesla cMRI, however, revealed the cause to be an acute posterior ischemic optic neuropathy. Cases like this may be more common than thought and quite regularly overlooked in clinical practice, especially when there is no high-resolution MRI available. This case strengthens the importance of repeat MR imaging in patients with persistent visual field defects.

  11. Acute Posterior Ischemic Optic Neuropathy Mimicking Posterior Cerebral Artery Stroke Visualized by 3-Tesla MRI

    Menzel, Tilman; Kern, Rolf; Griebe, Martin; Hennerici, Michael; Fatar, Marc

    2012-01-01

    Acute ischemic lesions of the posterior optic nerve and optic tract can produce a variety of visual field defects. A 71-year-old woman presented with acute hemianopia, which led to rt-PA thrombolysis for suspected posterior cerebral artery ischemia. 3-Tesla cMRI, however, revealed the cause to be an acute posterior ischemic optic neuropathy. Cases like this may be more common than thought and quite regularly overlooked in clinical practice, especially when there is no high-resolution MRI avai...

  12. Intraindividual comparison of image quality in MR urography at 1.5 and 3 Tesla in an animal model

    Purpose: experimental evaluation of image quality of the upper urinary tract in MR urography (MRU) at 1.5 and 3 Tesla in a porcine model. Materials and methods: in this study four healthy domestic pigs, weighing between 71 and 80 kg (mean 73.6 kg), were examined with a standard T 1w 3D-GRE and a high-resolution (HR) T 1w 3D-GRE sequence at 1.5 and 3 Tesla. Additionally, at 3 Tesla both sequences were performed with parallel imaging (SENSE factor 2). The MR urographic scans were performed after intravenous injection of gadolinium-DTPA (0.1 mmol/kg body weight (bw)) and low-dose furosemide (0.1 mg/kg bw). Image evaluation was performed by two independent radiologists blinded to sequence parameters and field strength. Image analysis included grading of image quality of the segmented collecting system based on a five-point grading scale regarding anatomical depiction and artifacts observed (1: the majority of the segment (> 50%) was not depicted or was obscured by major artifacts; 5: the segment was visualized without artifacts and had sharply defined borders). Signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were determined. Statistical analysis included κ-statistics, Wilcoxon and paired student t-test. Results: the mean scores for MR urographies at 1.5 Tesla were 2.83 for the 3D-GRE and 3.48 for the HR 3D-GRE sequence. Significantly higher values were determined using the corresponding sequences at 3 Tesla, averaging 3.19 for the 3D-GRE (p 0.047) and 3.92 for the HR 3D-GRE (p = 0.023) sequence. Delineation of the pelvicaliceal system was rated significantly higher at 3 Tesla compared to 1.5 Tesla (3D-GRE: p = 0.015; HR 3D-GRE: p = 0.006). At 3 Tesla the mean SNR and CNR were significantly higher (p < 0.05). A κ of 0.67 indicated good interobserver agreement. (orig.)

  13. Intraindividual comparison of image quality in MR urography at 1.5 and 3 Tesla in an animal model

    Regier, M.; Adam, G.; Kemper, J. [Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie, Universitaetsklinikum Hamburg-Eppendorf (Germany); Nolte-Ernsting, C. [Klinik fuer Diagnostische und Interventionelle Radiologie, Universitaetsklinikum Hamburg-Eppendorf (Germany)

    2008-10-15

    Purpose: experimental evaluation of image quality of the upper urinary tract in MR urography (MRU) at 1.5 and 3 Tesla in a porcine model. Materials and methods: in this study four healthy domestic pigs, weighing between 71 and 80 kg (mean 73.6 kg), were examined with a standard T 1w 3D-GRE and a high-resolution (HR) T 1w 3D-GRE sequence at 1.5 and 3 Tesla. Additionally, at 3 Tesla both sequences were performed with parallel imaging (SENSE factor 2). The MR urographic scans were performed after intravenous injection of gadolinium-DTPA (0.1 mmol/kg body weight (bw)) and low-dose furosemide (0.1 mg/kg bw). Image evaluation was performed by two independent radiologists blinded to sequence parameters and field strength. Image analysis included grading of image quality of the segmented collecting system based on a five-point grading scale regarding anatomical depiction and artifacts observed (1: the majority of the segment (> 50%) was not depicted or was obscured by major artifacts; 5: the segment was visualized without artifacts and had sharply defined borders). Signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were determined. Statistical analysis included {kappa}-statistics, Wilcoxon and paired student t-test. Results: the mean scores for MR urographies at 1.5 Tesla were 2.83 for the 3D-GRE and 3.48 for the HR 3D-GRE sequence. Significantly higher values were determined using the corresponding sequences at 3 Tesla, averaging 3.19 for the 3D-GRE (p = 0.047) and 3.92 for the HR 3D-GRE (p = 0.023) sequence. Delineation of the pelvicaliceal system was rated significantly higher at 3 Tesla compared to 1.5 Tesla (3D-GRE: p = 0.015; HR 3D-GRE: p = 0.006). At 3 Tesla the mean SNR and CNR were significantly higher (p < 0.05). A {kappa} of 0.67 indicated good interobserver agreement. (orig.)

  14. Dobutamine stress cardiovascular magnetic resonance at 3 Tesla

    Klein C

    2008-10-01

    Full Text Available Abstract Purpose The assessment of inducible wall motion abnormalities during high-dose dobutamine-stress cardiovascular magnetic resonance (DCMR is well established for the identification of myocardial ischemia at 1.5 Tesla. Its feasibility at higher field strengths has not been reported. The present study was performed to prospectively determine the feasibility and diagnostic accuracy of DCMR at 3 Tesla for depicting hemodynamically significant coronary artery stenosis (≥ 50% diameter stenosis in patients with suspected or known coronary artery disease (CAD. Materials and methods Thirty consecutive patients (6 women (66 ± 9.3 years were scheduled for DCMR between January and May 2007 for detection of coronary artery disease. Patients were examined with a Philips Achieva 3 Tesla system (Philips Healthcare, Best, The Netherlands, using a spoiled gradient echo cine sequence. Technical parameters were: spatial resolution 2 × 2 × 8 mm3, 30 heart phases, spoiled gradient echo TR/TE: 4.5/2.6 msec, flip angle 15°. Images were acquired at rest and stress in accordance with a standardized high-dose dobutamine-atropine protocol during short breath-holds in three short and three long-axis views. Dobutamine was administered using a standard protocol (10 μg increments every 3 minutes up to 40 μg dobutamine/kg body weight/minute plus atropine if required to reach target heart rate. The study protocol included administration of 0.1 mmol/kg/body weight Gd-DTPA before the cine images at rest were acquired to improve the image quality. The examination was terminated if new or worsening wall-motion abnormalities or chest pain occurred or when > 85% of age-predicted maximum heart rate was reached. Myocardial ischemia was defined as new onset of wall-motion abnormality in at least one segment. In addition, late gadolinium enhancement (LGE was performed. Images were evaluated by two blinded readers. Diagnostic accuracy was determined with coronary

  15. Molecular MRI differentiation between primary central nervous system lymphomas and high-grade gliomas using endogenous protein-based amide proton transfer MR imaging at 3 Tesla

    To show the ability of using the amide proton transfer-weighted (APTW) MRI signals as imaging biomarkers to differentiate primary central nervous system lymphomas (PCNSLs) from high-grade gliomas (HGGs). Eleven patients with lymphomas and 21 patients with HGGs were examined. Magnetization-transfer (MT) spectra over an offset range of ±6 ppm and the conventional MT ratio (MTR) at 15.6 ppm were acquired. The APTW signals, total chemical-exchange-saturation-transfer signal (integral between 0 and 5 ppm, CESTtotal), and MTR signal were obtained and compared between PCNSLs and HGGs. The diagnostic performance was assessed with the receiver operating characteristic (ROC) curve analysis. The PCNSLs usually showed more homogeneous APTW hyperintensity (spatially compared to normal brain tissue) than the HGGs. The APTWmax, APTWmax-min and CESTtotal signal intensities were significantly lower (P < 0.05, 0.001 and 0.05, respectively), while the APTWmin and MTR were significantly higher (both P < 0.01) in PCNSL lesions than in HGG lesions. The APTW values in peritumoral oedema were significantly lower for PCNSLs than for HGGs (P < 0.01). APTWmax-min had the highest area under the ROC curve (0.963) and accuracy (94.1 %) in differentiating PCNSLs from HGGs. The protein-based APTW signal would be a valuable MRI biomarker by which to identify PCNSLs and HGGs presurgically. (orig.)

  16. Molecular MRI differentiation between primary central nervous system lymphomas and high-grade gliomas using endogenous protein-based amide proton transfer MR imaging at 3 Tesla

    Jiang, Shanshan [Southern Medical University, Department of Radiology, Zhujiang Hospital, Guangzhou, Guangdong (China); Johns Hopkins University School of Medicine, Department of Radiology, Baltimore, MD (United States); Yu, Hao; Wang, Xianlong; Lu, Shilong; Feng, Lyujin; Wen, Zhibo [Southern Medical University, Department of Radiology, Zhujiang Hospital, Guangzhou, Guangdong (China); Li, Yufa [Southern Medical University, Department of Pathology, Zhujiang Hospital, Guangzhou, Guangdong (China); Zhang, Yi; Heo, Hye-Young; Lee, Dong-Hoon; Zhou, Jinyuan [Johns Hopkins University School of Medicine, Department of Radiology, Baltimore, MD (United States)

    2016-01-15

    To show the ability of using the amide proton transfer-weighted (APTW) MRI signals as imaging biomarkers to differentiate primary central nervous system lymphomas (PCNSLs) from high-grade gliomas (HGGs). Eleven patients with lymphomas and 21 patients with HGGs were examined. Magnetization-transfer (MT) spectra over an offset range of ±6 ppm and the conventional MT ratio (MTR) at 15.6 ppm were acquired. The APTW signals, total chemical-exchange-saturation-transfer signal (integral between 0 and 5 ppm, CEST{sub total}), and MTR signal were obtained and compared between PCNSLs and HGGs. The diagnostic performance was assessed with the receiver operating characteristic (ROC) curve analysis. The PCNSLs usually showed more homogeneous APTW hyperintensity (spatially compared to normal brain tissue) than the HGGs. The APTW{sub max}, APTW{sub max-min} and CEST{sub total} signal intensities were significantly lower (P < 0.05, 0.001 and 0.05, respectively), while the APTW{sub min} and MTR were significantly higher (both P < 0.01) in PCNSL lesions than in HGG lesions. The APTW values in peritumoral oedema were significantly lower for PCNSLs than for HGGs (P < 0.01). APTW{sub max-min} had the highest area under the ROC curve (0.963) and accuracy (94.1 %) in differentiating PCNSLs from HGGs. The protein-based APTW signal would be a valuable MRI biomarker by which to identify PCNSLs and HGGs presurgically. (orig.)

  17. Functional and perfusion magnetic resonance imaging at 3 tesla

    This thesis deals with the development and optimization of fast magnetic resonance imaging (MRI) methods for non-invasive functional studies of the human brain and perfusion imaging on a 3 Tesla (T) whole body NMR system. The functional MRI (fMRI) experiments performed showed that single-shot multi-echo EPI and spiral imaging techniques provide fast tools to obtain information about T2* distributions during functional activation in the human brain. Both sequences were found to be useful in the separation of different sources contributing to the functional MR signal like inflow or susceptibility effects in the various vascular environments. An fMRI study dealing with the involvement of prefrontal brain regions in movement preparation lead to inconsistent results. It could not be clarified if these were caused by problems during a spatial normalization process of the individual brains or if the functional paradigm, using very short inter-stimulus intervals, was not suited for the problem investigated. Blood flow velocity measurements in the human finger showed that the use of a strong, small-bore gradient system permits short echo times that reduce flow artefacts and allows high spatial resolution in order to keep systematic errors due to partial volume effects small. With regard to the perfusion investigations an inversion recovery snapshot-FLASH sequence was implemented, which allowed the acquisition of T1 parameter maps of the human brain within a few seconds. The accuracy of this method was demonstrated in test objects. The perfusion investigations with FAIR showed good qualitative results, whereas the quantitative analysis did not yield reproducible findings. A reason for the poor results could be the low signal-to-noise ratio (SNR) of the FAIR images or an incomplete global inversion of the magnetization due to the transmission characteristics of the radio-frequency coil. The BASE sequence that did not require a global inversion yielded quantitative perfusion

  18. Evaluation of 100 brain examinations using a 3 Tesla MR-compatible incubator - safety, handling, and image quality

    Several studies have revealed the importance of brain imaging in term and preterm infants. The aim of this retrospective study was to review safety, handling, and image quality of MR brain imaging using a new 3 Tesla MR-compatible incubator. Between 02/2011 and 05/2012 100 brain MRIs (84 infants, mean gestational age 32.2 ± 4.7 weeks, mean postmenstrual age at imaging 40.6 ± 3.4 weeks) were performed using a 3 Tesla MR-compatible incubator with dedicated, compatible head coil. Seventeen examinations (13 infants, mean gestational age 35.1 ± 5.4 weeks, mean postmenstrual age at imaging 47.8 ± 7.4 weeks) with a standard head coil served as a control. Image analysis was performed by a neuroradiologist and a pediatric radiologist in consensus. All but two patients with known apnea were transferred to the MR unit and scanned without problems. Handling was easier and faster with the incubator; relevant motion artifacts (5.9 vs. 10.8 %) and the need for repetitive sedation (43.0 vs. 86.7 %) were reduced. Considering only images not impaired by motion artifacts, image quality (4.8 ± 0.4 vs. 4.3 ± 0.8, p = 0.047) and spatial resolution (4.7 ± 0.4 vs. 4.2 ± 0.6, p = 0.011) of T2-weighted images were scored significantly higher in patients imaged with the incubator. SNR increased significantly (171.6 ± 54.5 vs. 80.5 ± 19.8, p < 0.001) with the use of the incubator. Infants can benefit from the use of a 3 Tesla MR-compatible incubator because of its safety, easier, and faster handling (compared to standard imaging) and possibility to obtain high-quality MR images even in unstable patients. (orig.)

  19. Evaluation of 100 brain examinations using a 3 Tesla MR-compatible incubator - safety, handling, and image quality

    Sirin, Selma; Goericke, Sophia L.; Kinner, Sonja; Schweiger, Bernd [University Hospital Essen, Institute of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Huening, Britta M.; Stein, Anja; Felderhoff-Mueser, Ursula [University Hospital Essen, Department of Neonatology, Division of Pediatrics I, Essen (Germany)

    2013-10-15

    Several studies have revealed the importance of brain imaging in term and preterm infants. The aim of this retrospective study was to review safety, handling, and image quality of MR brain imaging using a new 3 Tesla MR-compatible incubator. Between 02/2011 and 05/2012 100 brain MRIs (84 infants, mean gestational age 32.2 {+-} 4.7 weeks, mean postmenstrual age at imaging 40.6 {+-} 3.4 weeks) were performed using a 3 Tesla MR-compatible incubator with dedicated, compatible head coil. Seventeen examinations (13 infants, mean gestational age 35.1 {+-} 5.4 weeks, mean postmenstrual age at imaging 47.8 {+-} 7.4 weeks) with a standard head coil served as a control. Image analysis was performed by a neuroradiologist and a pediatric radiologist in consensus. All but two patients with known apnea were transferred to the MR unit and scanned without problems. Handling was easier and faster with the incubator; relevant motion artifacts (5.9 vs. 10.8 %) and the need for repetitive sedation (43.0 vs. 86.7 %) were reduced. Considering only images not impaired by motion artifacts, image quality (4.8 {+-} 0.4 vs. 4.3 {+-} 0.8, p = 0.047) and spatial resolution (4.7 {+-} 0.4 vs. 4.2 {+-} 0.6, p = 0.011) of T2-weighted images were scored significantly higher in patients imaged with the incubator. SNR increased significantly (171.6 {+-} 54.5 vs. 80.5 {+-} 19.8, p < 0.001) with the use of the incubator. Infants can benefit from the use of a 3 Tesla MR-compatible incubator because of its safety, easier, and faster handling (compared to standard imaging) and possibility to obtain high-quality MR images even in unstable patients. (orig.)

  20. 3 Tesla proton MRI for the diagnosis of pneumonia/lung infiltrates in neutropenic patients with acute myeloid leukemia: Initial results in comparison to HRCT

    Purpose: To evaluate the diagnostic accuracy of 3 Tesla proton MRI for the assessment of pneumonia/lung infiltrates in neutropenic patients with acute myeloid leukemia. Material and methods: In a prospective study, 3 Tesla MRI was performed in 19 febrile neutropenic patients (5 women, 14 men; mean age 61 years ± 14.2; range 23–77 years). All patients underwent high-resolution CT less than 24 h prior to MRI. The MRI protocol (Magnetom Tim Trio, Siemens) included a T2-weighted HASTE sequence (TE/TR: 49 ms/∞, slice thickness 6 mm) and a high-resolution 3D VIBE sequence with an ultra-short TE < 1 ms (TE/TR 0.8/2.9 ms, slice thickness 2 mm). The VIBE sequence was examined before and after intravenous injection of 0.1 mmol/kg gadoterate meglumine (Dotarem, Guerbet). The presence of pulmonary abnormalities, their location within the lung, and lesion type (nodules, consolidations, glass opacity areas) were analyzed by one reader and compared to the findings of HRCT, which was evaluated by a second independent radiologist who served as the reference standard. The findings were compared per lobe in each patient and rated as true positive (TP) findings if all three characteristics (presence, location, and lesion type) listed above were concordant to HRCT. Results: Pulmonary abnormalities were characterized by 3 Tesla MRI with a sensitivity of 82.3% and a specificity of 78.6%, resulting in an overall accuracy of 88% (NPV/PPV 66.7%/89.5%). In 51 lobes (19 of 19 patients), pulmonary abnormalities visualized by MR were judged to be concordant in their location and in the lesion type identified by both readers. In 22 lobes (11 of 19 patients), no abnormalities were present on either MR or HRCT (true negative). In 6 lobes (5 of 19 patients), ground glass opacity areas were detected on MRI but were not visible on HRCT (false positives). In 11 lobes (7 of 19 patients), MRI failed to detect ground glass opacity areas identified by HRCT. However, since the abnormalities were

  1. 3 Tesla proton MRI for the diagnosis of pneumonia/lung infiltrates in neutropenic patients with acute myeloid leukemia: Initial results in comparison to HRCT

    Attenberger, U.I., E-mail: ulrike.attenberger@umm.de [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim (Germany); Morelli, J.N. [Scott and White Hospital, Texas A and M Health Sciences Center, Temple (United States); Henzler, T. [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim (Germany); Buchheidt, D. [Department of Hematology and Oncology, University Medical Center Mannheim (Germany); Fink, C. [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim (Germany); Department of Radiology, AKH Celle, Celle (Germany); Schoenberg, S.O.; Reichert, M. [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim (Germany)

    2014-01-15

    Purpose: To evaluate the diagnostic accuracy of 3 Tesla proton MRI for the assessment of pneumonia/lung infiltrates in neutropenic patients with acute myeloid leukemia. Material and methods: In a prospective study, 3 Tesla MRI was performed in 19 febrile neutropenic patients (5 women, 14 men; mean age 61 years ± 14.2; range 23–77 years). All patients underwent high-resolution CT less than 24 h prior to MRI. The MRI protocol (Magnetom Tim Trio, Siemens) included a T2-weighted HASTE sequence (TE/TR: 49 ms/∞, slice thickness 6 mm) and a high-resolution 3D VIBE sequence with an ultra-short TE < 1 ms (TE/TR 0.8/2.9 ms, slice thickness 2 mm). The VIBE sequence was examined before and after intravenous injection of 0.1 mmol/kg gadoterate meglumine (Dotarem, Guerbet). The presence of pulmonary abnormalities, their location within the lung, and lesion type (nodules, consolidations, glass opacity areas) were analyzed by one reader and compared to the findings of HRCT, which was evaluated by a second independent radiologist who served as the reference standard. The findings were compared per lobe in each patient and rated as true positive (TP) findings if all three characteristics (presence, location, and lesion type) listed above were concordant to HRCT. Results: Pulmonary abnormalities were characterized by 3 Tesla MRI with a sensitivity of 82.3% and a specificity of 78.6%, resulting in an overall accuracy of 88% (NPV/PPV 66.7%/89.5%). In 51 lobes (19 of 19 patients), pulmonary abnormalities visualized by MR were judged to be concordant in their location and in the lesion type identified by both readers. In 22 lobes (11 of 19 patients), no abnormalities were present on either MR or HRCT (true negative). In 6 lobes (5 of 19 patients), ground glass opacity areas were detected on MRI but were not visible on HRCT (false positives). In 11 lobes (7 of 19 patients), MRI failed to detect ground glass opacity areas identified by HRCT. However, since the abnormalities were

  2. Imaging Findings of Brain Death on 3-Tesla MRI

    To demonstrate the usefulness of 3-tesla (3T) magnetic resonance imaging (MRI) including T2-weighted imaging (T2WI), diffusion weighted imaging (DWI), time-of-flight (TOF) magnetic resonance angiography (MRA), T2*-weighted gradient recalled echo (GRE), and susceptibility weighted imaging (SWI) in diagnosing brain death. Magnetic resonance imaging findings for 10 patients with clinically verified brain death (group I) and seven patients with comatose or stuporous mentality who did not meet the clinical criteria of brain death (group II) were retrospectively reviewed. Tonsilar herniation and loss of intraarterial flow signal voids (LIFSV) on T2WI were highly sensitive and specific findings for the diagnosis of brain death (p < 0.001 and < 0.001, respectively). DWI, TOF-MRA, and GRE findings were statistically different between the two groups (p = 0.015, 0.029, and 0.003, respectively). However, cortical high signal intensities in T2WI and SWI findings were not statistically different between the two group (p = 0.412 and 1.0, respectively). T2-weighted imaging, DWI, and MRA using 3T MRI may be useful for diagnosing brain death. However, SWI findings are not specific due to high false positive findings.

  3. In Vivo High-Resolution 7 Tesla MRI Shows Early and Diffuse Cortical Alterations in CADASIL

    De Guio, François; Reyes, Sonia; Vignaud, Alexandre; Duering, Marco; Ropele, Stefan; Duchesnay, Edouard; Chabriat, Hugues; Jouvent, Eric

    2014-01-01

    Background and Purpose Recent data suggest that early symptoms may be related to cortex alterations in CADASIL (Cerebral Autosomal-Dominant Arteriopathy with Subcortical Infarcts and Leukoencephalopathy), a monogenic model of cerebral small vessel disease (SVD). The aim of this study was to investigate cortical alterations using both high-resolution T2* acquisitions obtained with 7 Tesla MRI and structural T1 images with 3 Tesla MRI in CADASIL patients with no or only mild symptomatology (mod...

  4. Technical Assessment of Artifact Production from Neuro Endovascular Coil At 3 Tesla MRI: An In Vitro Study

    Introduction: Magnetic resonance imaging (MRI) is an essential part of the diagnostic procedures in radiology. MRI 3 Tesla becomes more widespread due to high signal to noise ratio (SNR). The use of the neuro endovascular coil to overcome the neuro aneurysm can introduce the artifact in magnetic resonance imaging. Susceptibility artifacts and geometric distortions caused by magnetic field inhomogeneity- related signal loss is used to refer to an artifact in magnetic resonance images. It consists of a region of signal void with a surrounding area of an increased signal intensity that appears to be considerably larger than the actual size of the device causing the artifact. The objective of the study is to compare the size of the artifact on the MR image to the actual size of endovascular coils using a 3 Tesla magnetic resonance imaging system, in vitro study. Methods: The endovascular coils were made from detachable platinum and aneurysm models were constructed by using silicone tube. MRI 3 Tesla Philips Model Achieva with pulse sequence selections were: spin echo, fast spin echo, inversion recovery, fast gradient echo while additional parameters were echo time and turbo factor. Results: Improved visualization of perianeurysmal soft tissues is best accomplished by spin echo for fast spin echo sequences, even better suited to reduce metal artifact. Furthermore, shorter turbo factor and shorter effective TE in the latter sequences are beneficial for the same reason as sequences having shorter TE. Sequences with a shorter TE are preferred because of less time for dephasing and frequency shifting. Imaging at gradient echo series increases susceptibility artifacts. In this in vitro study, some of the major characteristics related to MRI imaging of coil packs have been defined. Discussion: Pulse sequence spin echo is the best sequence reducing the susceptibility artifact. Reducing the TE is the main factor in improving endovascular coil visualization on MRI images. The

  5. Prevalence of Incidental Pancreatic Cysts on 3 Tesla Magnetic Resonance

    de Oliveira, Patricia Bedesco; Puchnick, Andrea; Szejnfeld, Jacob; Goldman, Suzan Menasce

    2015-01-01

    Objectives To ascertain the prevalence of pancreatic cysts detected incidentally on 3-Tesla magnetic resonance imaging (MRI) of the abdomen and correlate this prevalence with patient age and gender; assess the number, location, and size of these lesions, as well as features suspicious for malignancy; and determine the prevalence of incidentally detected dilatation of the main pancreatic duct (MPD). Methods Retrospective analysis of 2,678 reports of patients who underwent abdominal MRI between...

  6. Detailed imaging of the normal anatomy and pathologic conditions of the cavernous region at 3 Tesla using a contrast-enhanced MR angiography

    The purpose of this study was to evaluate the potential of a high-resolution contrast-enhanced magnetic resonance angiography (CE-MRA) at 3 Tesla for the delineation of the cavernous sinus (CS) anatomy both under normal and under pathological conditions. Fifteen patients without pathologies in the CS and ten patients with pituitary adenomas were included. The CE-MRA was performed on a 3-Tesla scanner and analyzed collaboratively by two readers. The cranial nerves (CNs) within the CS, namely CNIII, CNIV, CNV1, CNV2, and CNVI, were identified in both patient groups. In the adenoma patients it was also assessed whether and to which extend the adenoma invaded the CS and the spatial relationship between tumor and CNs was determined. In the patients with normal CS anatomy, CNIII could be identified in 100%, CNIV in 86.7%, and CNV1, CNV2, as well as CNVI in 100% of analyzed sides. Pituitary adenomas invaded the CS unilaterally (right side) in four patients, and bilaterally in six patients. In patients with adenomas, the CN could be identified and differentiated from the tumor in the following percentages: CNIII in 100%, CNIV in 70%, both CNV1 and CNV2 in 90%, and CNVI in 100%. In all these cases, the tumor-nerve spatial relationship could be visualized. 3-Tesla CE-MRA allows detailed imaging of the complex anatomy of the CS and its structures. In adenoma patients, it clearly visualizes the spatial relationship between tumor and CNs, and thus might be helpful to optimize presurgical planning. (orig.)

  7. Detailed imaging of the normal anatomy and pathologic conditions of the cavernous region at 3 Tesla using a contrast-enhanced MR angiography

    Linn, Jennifer; Peters, Friederike; Lummel, Nina; Brueckmann, Hartmut; Yousry, Indra [University Hospital Munich, Department of Neuroradiology, Munich (Germany); Schankin, Christoph [University Hospital Munich, Department of Neurology, Munich (Germany); Rachinger, Walter [University Hospital Munich, Department of Neurosurgery, Munich (Germany)

    2011-12-15

    The purpose of this study was to evaluate the potential of a high-resolution contrast-enhanced magnetic resonance angiography (CE-MRA) at 3 Tesla for the delineation of the cavernous sinus (CS) anatomy both under normal and under pathological conditions. Fifteen patients without pathologies in the CS and ten patients with pituitary adenomas were included. The CE-MRA was performed on a 3-Tesla scanner and analyzed collaboratively by two readers. The cranial nerves (CNs) within the CS, namely CNIII, CNIV, CNV1, CNV2, and CNVI, were identified in both patient groups. In the adenoma patients it was also assessed whether and to which extend the adenoma invaded the CS and the spatial relationship between tumor and CNs was determined. In the patients with normal CS anatomy, CNIII could be identified in 100%, CNIV in 86.7%, and CNV1, CNV2, as well as CNVI in 100% of analyzed sides. Pituitary adenomas invaded the CS unilaterally (right side) in four patients, and bilaterally in six patients. In patients with adenomas, the CN could be identified and differentiated from the tumor in the following percentages: CNIII in 100%, CNIV in 70%, both CNV1 and CNV2 in 90%, and CNVI in 100%. In all these cases, the tumor-nerve spatial relationship could be visualized. 3-Tesla CE-MRA allows detailed imaging of the complex anatomy of the CS and its structures. In adenoma patients, it clearly visualizes the spatial relationship between tumor and CNs, and thus might be helpful to optimize presurgical planning. (orig.)

  8. A novel receive-only liquid nitrogen (LN2)-cooled RF coil for high-resolution in vivo imaging on a 3-Tesla whole-body scanner

    Hu, Bobo; Varma, Gopal; Randell, Chris; Keevil, Stephen F.; Schaeffter, Tobias; Glover, Paul

    2012-01-01

    The design and operation of a receive-only liquid nitrogen (LN2)-cooled coil and cryostat suitable for medical imaging on a 3-T whole-body magnetic resonance scanner is presented. The coil size, optimized for murine imaging, was determined by using electromagnetic (EM) simulations. This process is therefore easier and more cost effective than building a range of coils. A nonmagnetic cryostat suitable for small-animal imaging was developed having good vacuum and cryogenic temperature perform...

  9. Finite Element Modeling for a Morphometric and Mechanical Characterization of Trabecular Bone from High Resolution Magnetic Resonance Imaging

    Alberich-Bayarri, Angel; Marti-Bonmati, Luis; Perez, M. Angeles; Lerma, Juan José; Moratal, David

    2010-01-01

    Although further evaluation is needed about the usefulness of these methods in osteoporosis, it seems clear that computational generated 3D models of the cancellous bone from high resolution 3 Tesla MRI can be used to characterize bone in vivo, analyzing different mechanical conditions of the cancellous microstructure. The FE analysis could be performed in a more complex philosophy, if bone anisotropy is considered for bulk material properties definition (Hellmich et al., 2008), and also if n...

  10. Orbitofrontal lobe volume deficits in Antipsychotic-Naive schizophrenia: A 3-Tesla MRI study

    Behere Rishikesh

    2009-01-01

    Full Text Available Background: Prefrontal cortex deficits have been consistently demonstrated in schizophrenia. The orbitofrontal lobe (OFL, a critical component of the prefrontal cortex, subserves social and neuro-cognitive functions. While these functional impairments are established in schizophrenia, the OFL volume deficits have not been well studied, especially in antipsychotic-naοve patients. Aim: To study OFL volume deficits in antipsychotic-naοve schizophrenia patients in comparison with matched healthy controls using high-resolution 3-tesla (3T magnetic resonance imaging (MRI. Materials and Methods: Fourteen antipsychotic-naοve schizophrenia patients (DSM-IV and 14 age-, sex-, handedness- and education-matched healthy controls were scanned using 3T MRI. Psychopathology was assessed in the patient group using the scale for assessment of negative symptoms and the scale for assessment of positive symptoms (SAPS. The OFL volume was measured using Region of Interest (ROI-based manual morphometry technique, with good inter-rater reliability (intra-class correlation coefficient = 0.98. Results: Total OFL volume was significantly smaller in schizophrenia patients (43.3 ± 9.6 mL in comparison with healthy controls (52.1 ± 12.2 mL after controlling for the potential confounding effects of age, sex and intracranial volume (F = 5.3, P = .03. Duration of untreated psychosis did not correlate significantly with OFL volumes. There was a trend towards significant negative correlation between the left and total OFL volumes and SAPS scores (r = -0.49, P = .06. Conclusion: OFL volume deficits might underlie the pathogenesis of schizophrenia symptoms with possible neuro-developmental origins.

  11. High Resolution Actuators

    Mathieu Grossard

    2016-06-01

    Full Text Available Driven by increasing societal, economic, and technological pressures, high-resolution actuators must achieve ever increasing accuracy requirements and functional integration into the system.[...

  12. High Resolution Elevation Contours

    Minnesota Department of Natural Resources — This dataset contains contours generated from high resolution data sources such as LiDAR. Generally speaking this data is 2 foot or less contour interval.

  13. Cortical microinfarcts detected in vivo on 3 tesla MRI : Clinical and radiological correlates

    Van Dalen, Jan Willem; Scuric, Eva E M; Van Veluw, Susanne J.; Caan, Matthan W A; Nederveen, Aart J.; Biessels, Geert Jan; Van Gool, Willem A.; Richard, Edo

    2015-01-01

    Background and Purpose-Cortical microinfarcts (CMIs) are a common postmortem finding associated with vascular risk factors, cognitive decline, and dementia. Recently, CMIs identified in vivo on 7 Tesla MRI also proved retraceable on 3 Tesla MRI. Methods-We evaluated CMIs on 3 Tesla MRI in a populati

  14. Cortical microinfarcts detected in vivo on 3 Tesla MRI: clinical and radiological correlates

    Dalen, J.W. van; Scuric, E.E.; Veluw, S.J. van; Caan, M.W.; Nederveen, A.J.; Biessels, G.J.; Gool, W.A. van; Richard, E.

    2015-01-01

    BACKGROUND AND PURPOSE: Cortical microinfarcts (CMIs) are a common postmortem finding associated with vascular risk factors, cognitive decline, and dementia. Recently, CMIs identified in vivo on 7 Tesla MRI also proved retraceable on 3 Tesla MRI. METHODS: We evaluated CMIs on 3 Tesla MRI in a popula

  15. 'Tuning' for high resolution

    A review is given of some 'tuning' methods where the goal is to optimise energy resolution of particle spectra in two-body reactions. With a system consisting of an accelerator, beam analyser, beam transport system and magnetic spectrograph, its potential for high resolution, its limitations and the possibilities of optimising the resolution are investigated. The physics of matching to the spectrograph is considered, adjustments and diagnostics with the spectrograph at 00 are discussed and some on-line tuning methods are examined. (U.K.)

  16. Ultra high resolution tomography

    Haddad, W.S.

    1994-11-15

    Recent work and results on ultra high resolution three dimensional imaging with soft x-rays will be presented. This work is aimed at determining microscopic three dimensional structure of biological and material specimens. Three dimensional reconstructed images of a microscopic test object will be presented; the reconstruction has a resolution on the order of 1000 A in all three dimensions. Preliminary work with biological samples will also be shown, and the experimental and numerical methods used will be discussed.

  17. Functional and perfusion magnetic resonance imaging at 3 tesla

    Klarhoefer, M

    2001-01-01

    This thesis deals with the development and optimization of fast magnetic resonance imaging (MRI) methods for non-invasive functional studies of the human brain and perfusion imaging on a 3 Tesla (T) whole body NMR system. The functional MRI (fMRI) experiments performed showed that single-shot multi-echo EPI and spiral imaging techniques provide fast tools to obtain information about T2* distributions during functional activation in the human brain. Both sequences were found to be useful in the separation of different sources contributing to the functional MR signal like inflow or susceptibility effects in the various vascular environments. An fMRI study dealing with the involvement of prefrontal brain regions in movement preparation lead to inconsistent results. It could not be clarified if these were caused by problems during a spatial normalization process of the individual brains or if the functional paradigm, using very short inter-stimulus intervals, was not suited for the problem investigated. Blood flo...

  18. 3-Tesla functional magnetic resonance imaging-guided tumor resection

    Objective: We sought to determine the safety and efficacy of using 3-tesla (T) functional magnetic resonance imaging (fMRI) to guide brain tumor resection. Material and methods: From February 2004 to March 2006, fMRI was performed on 13 patients before surgical resection. Functional imaging was used to identify eloquent cortices for motor (8), speech (3), and motor and speech (2) activation using two different 3-T magnetic resonance (MR) scanners. Surgical resection was accomplished using a 1.5-T intraoperative MR system. Appropriate MR scan sequences were performed intraoperatively to determine and maximize the extent of the surgical resection. Results: Tumors included six oligodendrogliomas, three meningiomas, two astrocytomas and two glioblastomas multiforme. The fMRI data was accurate in all cases. After surgery, two patients had hemiparesis, two had worsening of their speech, and one had worsening of speech and motor function. Neurological function returned to normal in all patients within 1 month. Complete resections were possible in 10 patients (77%). Two patients had incomplete resections because of the proximity of their tumors to functional areas. Biopsy was performed in another patient with an astrocytoma in the motor strip. Conclusion: 3-T fMRI was accurate for locating neurologic function before tumor resection near eloquent cortex. (orig.)

  19. 3-Tesla functional magnetic resonance imaging-guided tumor resection

    Hall, W.A. [Univ. of Minnesota Medical School, Minneapolis, MN (United States). Depts. of Neurosurgery; Univ. of Minnesota Medical School, Minneapolis, MN (United States). Dept. of Radiation Oncology; Univ. of Minnesota Medical School, Minneapolis, MN (United States). Dept. of Radiology; University of Minnesota Medical Center (MMC), Minneapolis, MN (United States); Truwit, C.L. [Univ. of Minnesota Medical School, Minneapolis, MN (United States). Dept. of Radiology; Univ. of Minnesota Medical School, Minneapolis, MN (United States). Dept. of Pediatrics; Univ. of Minnesota Medical School, Minneapolis, MN (United States). Dept. of Neurology; Hennepin Country Medical Center, Minneapolis, MN (United States). Dept. of Radiology

    2006-12-15

    Objective: We sought to determine the safety and efficacy of using 3-tesla (T) functional magnetic resonance imaging (fMRI) to guide brain tumor resection. Material and methods: From February 2004 to March 2006, fMRI was performed on 13 patients before surgical resection. Functional imaging was used to identify eloquent cortices for motor (8), speech (3), and motor and speech (2) activation using two different 3-T magnetic resonance (MR) scanners. Surgical resection was accomplished using a 1.5-T intraoperative MR system. Appropriate MR scan sequences were performed intraoperatively to determine and maximize the extent of the surgical resection. Results: Tumors included six oligodendrogliomas, three meningiomas, two astrocytomas and two glioblastomas multiforme. The fMRI data was accurate in all cases. After surgery, two patients had hemiparesis, two had worsening of their speech, and one had worsening of speech and motor function. Neurological function returned to normal in all patients within 1 month. Complete resections were possible in 10 patients (77%). Two patients had incomplete resections because of the proximity of their tumors to functional areas. Biopsy was performed in another patient with an astrocytoma in the motor strip. Conclusion: 3-T fMRI was accurate for locating neurologic function before tumor resection near eloquent cortex. (orig.)

  20. 3 Tesla MR neurography - technique, interpretation, and pitfalls

    Chhabra, Avneesh; Lee, Pearlene P.; Bizzell, Cary; Soldatos, Theodoros [Johns Hopkins Hospital, Russell H. Morgan Department of Radiology and Radiological Science, Baltimore, MD (United States)

    2011-10-15

    MRI has been used for almost two decades for the evaluation of peripheral nerve disorders. This article highlights the relative advantages and disadvantages of 3T MR neurography in the evaluation of peripheral neuropathies. The authors also describe the high-resolution MR neurography technique on 3T MRI, along with the approach to its interpretation that has evolved at one institution. (orig.)

  1. High resolution drift chambers

    High precision drift chambers capable of achieving less than or equal to 50 μm resolutions are discussed. In particular, we compare so called cool and hot gases, various charge collection geometries, several timing techniques and we also discuss some systematic problems. We also present what we would consider an ''ultimate'' design of the vertex chamber. 50 refs., 36 figs., 6 tabs

  2. High-resolution headlamp

    Gut, Carsten; Cristea, Iulia; Neumann, Cornelius

    2016-04-01

    The following article shall describe how human vision by night can be influenced. At first, front lighting systems that are already available on the market will be described, followed by their analysis with respect to the positive effects on traffic safety. Furthermore, how traffic safety by night can be increased since the introduction of high resolution headlamps shall be discussed.

  3. Prevalence of Incidental Pancreatic Cysts on 3 Tesla Magnetic Resonance

    de Oliveira, Patricia Bedesco; Puchnick, Andrea; Szejnfeld, Jacob; Goldman, Suzan Menasce

    2015-01-01

    Objectives To ascertain the prevalence of pancreatic cysts detected incidentally on 3-Tesla magnetic resonance imaging (MRI) of the abdomen and correlate this prevalence with patient age and gender; assess the number, location, and size of these lesions, as well as features suspicious for malignancy; and determine the prevalence of incidentally detected dilatation of the main pancreatic duct (MPD). Methods Retrospective analysis of 2,678 reports of patients who underwent abdominal MRI between January 2012 and June 2013. Patients with a known history of pancreatic conditions or surgery were excluded, and the remaining 2,583 reports were examined for the presence of pancreatic cysts, which was then correlated with patient age and gender. We also assessed whether cysts were solitary or multiple, as well as their location within the pancreatic parenchyma, size, and features suspicious for malignancy. Finally, we calculated the prevalence of incidental MPD dilatation, defined as MPD diameter ≥ 2.5 mm. Results Pancreatic cysts were detected incidentally in 9.3% of patients (239/2,583). The prevalence of pancreatic cysts increased significantly with age (p<0.0001). There were no significant differences in prevalence between men and women (p=0.588). Most cysts were multiple (57.3%), distributed diffusely throughout the pancreas (41.8%), and 5 mm or larger (81.6%). In 12.1% of cases, cysts exhibited features suspicious for malignancy. Overall, 2.7% of subjects exhibited incidental MPD dilatation. Conclusions In this sample, the prevalence of pancreatic cysts detected incidentally on 3T MRI of the abdomen was 9.3%. Prevalence increased with age and was not associated with gender. The majority of cysts were multiple, diffusely distributed through the pancreatic parenchyma, and ≥ 5 mm in size; 12.1% were suspicious for malignancy. An estimated 2.7% of subjects had a dilated MPD. PMID:25798910

  4. High resolution differential thermometer

    Gotra Z. Yu.; Holyaka R. L.; Pavlov S. V.; Kulenko S. S.; Manus O. V.

    2009-01-01

    Main schematic solutions of differential thermometers with measurement resolution about 0.001°C are considered. Differential temperature primary transducer realized on a transistor differential circuit in microampere mode. Analytic calculation and schematic mathematic simulation of primary transducer are fulfilled. Signal transducer is realized on a high precision Zero-Drift Single-Supply Rail-to-Rail operation amplifier AD8552 and 24-Bit S-D microconverter ADuC834.

  5. High resolution differential thermometer

    Gotra Z. Yu.

    2009-11-01

    Full Text Available Main schematic solutions of differential thermometers with measurement resolution about 0.001°C are considered. Differential temperature primary transducer realized on a transistor differential circuit in microampere mode. Analytic calculation and schematic mathematic simulation of primary transducer are fulfilled. Signal transducer is realized on a high precision Zero-Drift Single-Supply Rail-to-Rail operation amplifier AD8552 and 24-Bit S-D microconverter ADuC834.

  6. Evaluation of slice accelerations using multiband echo planar imaging at 3 Tesla

    Xu, Junqian; Moeller, Steen; Auerbach, Edward J.; Strupp, John; Stephen M Smith; Feinberg, David A.; Yacoub, Essa; Uğurbil, Kâmil

    2013-01-01

    We evaluate residual aliasing among simultaneously excited and acquired slices in slice accelerated multiband (MB) echo planar imaging (EPI). No in-plane accelerations were used in order to maximize and evaluate achievable slice acceleration factors at 3 Tesla. We propose a novel leakage (L-) factor to quantify the effects of signal leakage between simultaneously acquired slices. With a standard 32-channel receiver coil at 3 Tesla, we demonstrate that slice acceleration factors of up to eight...

  7. High Resolution Laboratory Spectroscopy

    Brünken, Sandra

    2016-01-01

    In this short review we will highlight some of the recent advancements in the field of high-resolution laboratory spectroscopy that meet the needs dictated by the advent of highly sensitive and broadband telescopes like ALMA and SOFIA. Among these is the development of broadband techniques for the study of complex organic molecules, like fast scanning conventional absorption spectroscopy based on multiplier chains, chirped pulse instrumentation, or the use of synchrotron facilities. Of similar importance is the extension of the accessible frequency range to THz frequencies, where many light hydrides have their ground state rotational transitions. Another key experimental challenge is the production of sufficiently high number densities of refractory and transient species in the laboratory, where discharges have proven to be efficient sources that can also be coupled to molecular jets. For ionic molecular species sensitive action spectroscopic schemes have recently been developed to overcome some of the limita...

  8. Experimental autoimmune encephalomyelitis (EAE): lesion visualization on a 3 tesla Clinical whole-body system after intraperitoneal contrast injection

    Heckl, S.; Naegele, T.; Klose, U. [Dept. of Neuroradiology, Medical School, Univ. of Tuebingen (Germany); Herrmann, M.; Gaertner, S.; Weissert, R. [Dept. of Neurology, Medical School, Univ. of Tuebingen (Germany); Schick, F. [Dept. of Radiology, Medical School, Univ. of Tuebingen (Germany); Kueker, W. [Dept. of Neuroradiology, Medical School, Univ. of Tuebingen (Germany); Dept. of Neuroradiology, Radcliffe Infirmary, Oxford, England (United Kingdom)

    2004-11-01

    Purpose: To investigate the intravital visibility of CNS lesions in rats with experimental autoimmune encephalomyelitis (EAE), the animal correlate of multiple sclerosis, using a 3-Tesla (T) wholebody MR system. Materials and Methods: Three healthy Dark Agouti (DA) rats and 16 DA rats with clinical signs of EAE were examined on a 3T whole body-system using a normal wrist coil. In total, 25 examinations were preformed using T2- and T1-weighted images in transverse and sagittal orientation with a slice thickness of 2 mm or 1 mm (voxel size up to 0.2 x 0.2 x 1 mm). Sedation was achieved by intraperitoneal injection of ketamine and xylazine. In addition, T1-weighted images were obtained after the instillation of 1.0 ml of gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA) (0.5 mmol/ml) into the peritoneal cavity. Results: T2- and T1-weighted images of the brain and spinal cord with high spatial and contrast resolution could be obtained in all animals. The anatomical details of the olfactory bulb glomeruli, cerebellum foliae, ventricles and corpus callosum were clearly visible. The EAE lesions presented as hyperintense area in T2-weighted images and could be demonstrated in all clinically affected animals by MRI and histologically verified. In total, the 16 affected rats had 28 cerebral and 2 spinal cord lesions (range 1 to 4, median 2). Contrast enhancement was noted in 12 animals and ranked as severe in ten and moderate in two cases. No adverse effects were noted due to sedation or intraperitoneal contrast injection. Conclusions: The intravital demonstration of cerebral and spinal cord EAE lesions in rats is possible on a 3T whole-body MR scanner using a normal wrist coil. Intraperitoneal injection of ketamine/xylazine and contrast agent is an easy, safe and effective procedure in rats. (orig.)

  9. Parallel RF transmission with eight channels at 3 Tesla.

    Setsompop, Kawin; Wald, Lawrence L; Alagappan, Vijayanand; Gagoski, Borjan; Hebrank, Franz; Fontius, Ulrich; Schmitt, Franz; Adalsteinsson, Elfar

    2006-11-01

    Spatially selective RF waveforms were designed and demonstrated for parallel excitation with a dedicated eight-coil transmit array on a modified 3T human MRI scanner. Measured excitation profiles of individual coils in the array were used in a low-flip-angle pulse design to achieve desired spatial target profiles with two- (2D) and three-dimensional (3D) k-space excitation with simultaneous transmission of RF on eight channels. The 2D pulse excited a high-resolution spatial pattern in-plane, while the 3D trajectory produced high-quality slice selection with a uniform in-plane excitation despite the highly nonuniform individual spatial profiles of the coil array. The multichannel parallel RF excitation was used to accelerate the 2D excitation by factors of 2-8, and experimental results were in excellent agreement with simulations based on the measured coil maps. Parallel RF transmission may become critical for robust and routine human studies at very high field strengths where B(1) inhomogeneity is commonly severe. PMID:17036289

  10. High-resolution CT

    The high-resolution CT (HRCT) appearance of the costal pleura was evaluated in a cadaver and 25 healthy subjects. The HRCT findings in healthy subjects were contrasted with the HCRT appearance of the costal pleura in 15 patients with mild pleural thickening, 13 of whom had been exposed to asbestos. On HRCT scans of the cadaver and the healthy subjects, a 1-2 mm soft-tissue density line seen at the point of contact between lung and chest wall represented the visceral and parietal pleura, pleural contents, endothoracic fascia, and innermost intercostal muscle. In a paravertebral location, the innermost intercostal muscle was lacking, and a thin line visible on HRCT scans represented only pleura and endothoracic fascia. In 13 of 15 patients with mild pleural thickening, the 1-3 mm thick pleura was separable from the adjacent intercostal muscle by a layer of extrapleural fat. HRCT was more sensitive than CT with 1-cm collimation in detecting this degree of pleural abnormality

  11. Clinical Evaluation of Stereotactic Target Localization Using 3-Tesla MRI for Radiosurgery Planning

    Purpose: Increasing the magnetic resonance imaging (MRI) field strength can improve image resolution and quality, but concerns remain regarding the influence on geometric fidelity. The objectives of the present study were to spatially investigate the effect of 3-Tesla (3T) MRI on clinical target localization for stereotactic radiosurgery. Methods and Materials: A total of 39 patients were enrolled in a research ethics board-approved prospective clinical trial. Imaging (1.5T and 3T MRI and computed tomography) was performed after stereotactic frame placement. Stereotactic target localization at 1.5T vs. 3T was retrospectively analyzed in a representative cohort of patients with tumor (n = 4) and functional (n = 5) radiosurgical targets. The spatial congruency of the tumor gross target volumes was determined by the mean discrepancy between the average gross target volume surfaces at 1.5T and 3T. Reproducibility was assessed by the displacement from an averaged surface and volume congruency. Spatial congruency and the reproducibility of functional radiosurgical targets was determined by comparing the mean and standard deviation of the isocenter coordinates. Results: Overall, the mean absolute discrepancy across all patients was 0.67 mm (95% confidence interval, 0.51-0.83), significantly .4), and the gross target volume surface mean displacements were similar within and between users. The overall average isocenter coordinate discrepancy for the functional targets at 1.5T and 3T was 0.33 mm (95% confidence interval, 0.20-0.48), with no patient-specific differences between the mean values (p >.2) or standard deviations (p >.1). Conclusion: Our results have provided clinically relevant evidence supporting the spatial validity of 3T MRI for use in stereotactic radiosurgery under the imaging conditions used.

  12. High Resolution Formaldehyde Photochemistry

    Ernest, C. T.; Bauer, D.; Hynes, A. J.

    2010-12-01

    Formaldehyde (HCHO) is the most abundant and most important organic carbonyl compound in the atmosphere. The sources of formaldehyde are the oxidation of methane, isoprene, acetone, and other volatile organic compounds (VOCs); fossil fuel combustion; and biomass burning. The dominant loss mechanism for formaldehyde is photolysis which occurs via two pathways: (R1) HCHO + hv → HCO + H (R2) HCHO + hv → H2 + CO The first pathway (R1) is referred to as the radical channel, while the second pathway (R2) is referred to as the molecular channel. The products of both pathways play a significant role in atmospheric chemistry. The CO that is produced in the molecular channel undergoes further oxidation to produce CO2. Under atmospheric conditions, the H atom and formyl radical that are produced in the radical channel undergo rapid reactions with O2 to produce the hydroperoxyl radical (HO2) via (R3) and (R4). (R3) HCO + O2 → HO2 + CO (R4) H + O2 → HO2 Thus, for every photon absorbed, the photolysis of formaldehyde can contribute one CO2 molecule to the global greenhouse budget or two HO2 radicals to the tropospheric HOx (OH + HO2) cycle. The HO2 radicals produced during formaldehyde photolysis have also been implicated in the formation of photochemical smog. The HO2 radicals act as radical chain carriers and convert NO to NO2, which ultimately results in the catalytic production of O3. Constraining the yield of HO2 produced via HCHO photolysis is essential for improving tropospheric chemistry models. In this study, both the absorption cross section and the quantum yield of the radical channel (R1) were measured at high resolution over the tropospherically relevant wavelength range 304-330 nm. For the cross section measurements a narrow linewidth Nd:YAG pumped dye laser was used with a multi-pass cell. Partial pressures of HCHO were kept below 0.3 torr. Simultaneous measurement of OH LIF in a flame allowed absolute calibration of the wavelength scale. Pressure

  13. High resolution telescope

    Massie, Norbert A.; Oster, Yale

    1992-01-01

    A large effective-aperture, low-cost optical telescope with diffraction-limited resolution enables ground-based observation of near-earth space objects. The telescope has a non-redundant, thinned-aperture array in a center-mount, single-structure space frame. It employs speckle interferometric imaging to achieve diffraction-limited resolution. The signal-to-noise ratio problem is mitigated by moving the wavelength of operation to the near-IR, and the image is sensed by a Silicon CCD. The steerable, single-structure array presents a constant pupil. The center-mount, radar-like mount enables low-earth orbit space objects to be tracked as well as increases stiffness of the space frame. In the preferred embodiment, the array has elemental telescopes with subaperture of 2.1 m in a circle-of-nine configuration. The telescope array has an effective aperture of 12 m which provides a diffraction-limited resolution of 0.02 arc seconds. Pathlength matching of the telescope array is maintained by an electro-optical system employing laser metrology. Speckle imaging relaxes pathlength matching tolerance by one order of magnitude as compared to phased arrays. Many features of the telescope contribute to substantial reduction in costs. These include eliminating the conventional protective dome and reducing on-site construction activites. The cost of the telescope scales with the first power of the aperture rather than its third power as in conventional telescopes.

  14. High resolution elastic recoil detection

    The quantitative analysis of light elements in ultra thin films being thinner than 10 nm is still a nontrivial task. This paper will summarise the prospects of high resolution elastic recoil detection (ERD) using a Q3D magnetic spectrograph. It has been shown that subnanometer resolution can be achieved in ultra thin films and even monolayer resolution is possible close to the surface. ERD has best quantification possibilities compared to any other method. Sensitivity is sufficient to analyse main elements and impurities as e.g. being necessary for the characterisation of microelectronic materials. In addition, high resolution channeling ERD can be performed in order to get information on lattice location of light elements in crystalline ultra thin layers. The potential of high resolution ERD will be demonstrated by several applications where it is the most valuable tool for elemental profiling

  15. Differentiation of brain metastases by percentagewise quantification of intratumoral-susceptibility-signals at 3 Tesla

    Introduction: Evaluation of intratumoral-susceptibility-signals (ITSS) in susceptibility-weighted-imaging (SWI) has been reported to improve diagnostic performance for solitary enhancing brain lesions. Due to the distinct morphologic variability of ITSS, standardized evaluation proved to be difficult. We analyzed, if a new postprocessing method using percentagewise quantification (PQ) of ITSS enables differentiation between different entities of cerebral metastases and may thus improve differential diagnosis in cases of unknown primary. Materials and methods: SWI and contrast enhanced T1-weighted MR images were acquired from 84 patients with intracerebral metastases (20 patients with mamma carcinoma (MC), 15 patients with malignant melanoma (MM), 49 patients with bronchial carcinoma (BC)) at 3 Tesla MR. Images were co-registered and enhancing lesions were delineated on T1-weighted images and the outline transferred to the corresponding SWI map. All voxels within the lesion presenting values below a reference value placed in the ventricular system were determined and percentagewise calculated. Results: Diagnostic performance of percentagewise quantification (PQ) of ITSS, as determined with area under the receiver operating characteristic curve (AUC) was excellent (AUC = 0.96; 95% confidence interval (CI) 0.90, 1.00) to discriminate MM from MC, good for the discrimination of MM and BC (AUC = 0.81, 95% CI 0.70, 0.92) and poor for the discrimination of MC and BC (AUC = 0.60; 95% CI 0.47, 0.73). Conclusion: PQ is a new approach for the assessment of SWI that can be used for differential diagnosis of intracerebral metastases. Metastases of MM and MC or BC can be distinguished with high sensitivity and specificity.

  16. High Resolution Doppler Lidar

    1996-01-01

    This Grant supported the development of an incoherent lidar system to measure winds and aerosols in the lower atmosphere. During this period the following activities occurred: (1) an active feedback system was developed to improve the laser frequency stability; (2) a detailed forward model of the instrument was developed to take into account many subtle effects, such as detector non-linearity; (3) a non-linear least squares inversion method was developed to recover the Doppler shift and aerosol backscatter without requiring assumptions about the molecular component of the signal; (4) a study was done of the effects of systematic errors due to multiple etalon misalignment. It was discovered that even for small offsets and high aerosol loadings, the wind determination can be biased by as much as 1 m/s. The forward model and inversion process were modified to account for this effect; and (5) the lidar measurements were validated using rawinsonde balloon measurements. The measurements were found to be in agreement within 1-2 m/s.

  17. MRI at 3 Tesla detects no evidence for ischemic brain damage in intensively treated patients with homozygous familial hypercholesterolemia

    Schmitz, Stephan A.; O' Regan, Declan P.; Fitzpatrick, Julie; Hajnal, Joseph V. [Hammersmith Hospital Campus, Imaging Sciences Department, MRC Clinical Sciences Centre, Faculty of Medicine, Imperial College, London (United Kingdom); Neuwirth, Clare; Potter, Elizabeth; Tosi, Isabella; Naoumova, Rossi P. [MRC Clinical Sciences Centre, Clinical Research Facility, London (United Kingdom); Hammersmith Hospital, Lipid Clinic, London (United Kingdom)

    2007-11-15

    Homozygous familial hypercholesterolemia (FH) is considered a model disease for excessive plasma cholesterol levels. Patients with untreated homozygous FH have a markedly increased risk for premature atherosclerosis. The frequency and extent of ischemic brain damage detectable by high-field magnetic resonance imaging (MRI) after long-term intensive treatment are unknown. In a case control study, five patients with homozygous FH (one male and four females; mean age: 23.6 {+-} 9.2, range: 12-36 years; mean pre-treatment serum total cholesterol level: 26.9 {+-} 3.24 mmol/L; all patients with documented atherosclerotic plaques in the carotid arteries) and five age- and sex-matched healthy controls were studied. All patients had been on maximal lipid-lowering medication since early childhood, and four of them were also on treatment with low-density lipoprotein (LDL) apheresis at bi-weekly intervals. Brain MRI was performed at 3 Tesla field strength with fluid-attenuated T2-weighted inversion recovery and T1-weighted spin-echo MR pulse sequences and subsequently evaluated by two independent readers. The maximal lipid-lowering treatment reduced the total serum cholesterol by more than 50% in the patients, but their serum concentrations were still 3.6-fold higher than those found in the controls (11.9 {+-} 4.2 vs. 4.5 {+-} 0.5 mmol/L; p < 0.0047). No brain abnormality was observed in any of the patients with homozygous FH. Homozygous FH patients on intensive cholesterol-lowering therapy have no evidence of ischemic brain damage at 3 Tesla MRI despite the remaining high cholesterol levels. (orig.)

  18. MRI at 3 Tesla detects no evidence for ischemic brain damage in intensively treated patients with homozygous familial hypercholesterolemia

    Homozygous familial hypercholesterolemia (FH) is considered a model disease for excessive plasma cholesterol levels. Patients with untreated homozygous FH have a markedly increased risk for premature atherosclerosis. The frequency and extent of ischemic brain damage detectable by high-field magnetic resonance imaging (MRI) after long-term intensive treatment are unknown. In a case control study, five patients with homozygous FH (one male and four females; mean age: 23.6 ± 9.2, range: 12-36 years; mean pre-treatment serum total cholesterol level: 26.9 ± 3.24 mmol/L; all patients with documented atherosclerotic plaques in the carotid arteries) and five age- and sex-matched healthy controls were studied. All patients had been on maximal lipid-lowering medication since early childhood, and four of them were also on treatment with low-density lipoprotein (LDL) apheresis at bi-weekly intervals. Brain MRI was performed at 3 Tesla field strength with fluid-attenuated T2-weighted inversion recovery and T1-weighted spin-echo MR pulse sequences and subsequently evaluated by two independent readers. The maximal lipid-lowering treatment reduced the total serum cholesterol by more than 50% in the patients, but their serum concentrations were still 3.6-fold higher than those found in the controls (11.9 ± 4.2 vs. 4.5 ± 0.5 mmol/L; p < 0.0047). No brain abnormality was observed in any of the patients with homozygous FH. Homozygous FH patients on intensive cholesterol-lowering therapy have no evidence of ischemic brain damage at 3 Tesla MRI despite the remaining high cholesterol levels. (orig.)

  19. Berkeley High-Resolution Ball

    Criteria for a high-resolution γ-ray system are discussed. Desirable properties are high resolution, good response function, and moderate solid angle so as to achieve not only double- but triple-coincidences with good statistics. The Berkeley High-Resolution Ball involved the first use of bismuth germanate (BGO) for anti-Compton shield for Ge detectors. The resulting compact shield permitted rather close packing of 21 detectors around a target. In addition, a small central BGO ball gives the total γ-ray energy and multiplicity, as well as the angular pattern of the γ rays. The 21-detector array is nearly complete, and the central ball has been designed, but not yet constructed. First results taken with 9 detector modules are shown for the nucleus 156Er. The complex decay scheme indicates a transition from collective rotation (prolate shape) to single- particle states (possibly oblate) near spin 30 h, and has other interesting features

  20. High resolution stopwatch for cents

    Gingl, Zoltan

    2011-01-01

    A very low-cost, easy-to-make stopwatch is presented to support various experiments in mechanics. The high-resolution stopwatch is based on two photodetectors connected directly to the microphone input of the sound card. A dedicated free open-source software has been developed and made available to download. The efficiency is demonstrated by a free fall experiment.

  1. High Resolution Orientation Distribution Function

    Schmidt, Søren; Gade-Nielsen, Nicolai Fog; Høstergaard, Martin;

    2012-01-01

    A new method for reconstructing a High Resolution Orientation Distribution Function (HRODF) from X-ray diffraction data is presented. It is shown that the method is capable of accommodating very localized features, e.g. sharp peaks from recrystallized grains on a background of a texture component...

  2. Requirements on high resolution detectors

    Koch, A. [European Synchrotron Radiation Facility, Grenoble (France)

    1997-02-01

    For a number of microtomography applications X-ray detectors with a spatial resolution of 1 {mu}m are required. This high spatial resolution will influence and degrade other parameters of secondary importance like detective quantum efficiency (DQE), dynamic range, linearity and frame rate. This note summarizes the most important arguments, for and against those detector systems which could be considered. This article discusses the mutual dependencies between the various figures which characterize a detector, and tries to give some ideas on how to proceed in order to improve present technology.

  3. Incidental optochiasmatic cavernoma: Case report of an unusual finding on 3 Tesla MRI.

    Trentadue, Mirko; Pozzi Mucelli, Roberto; Piovan, Enrico; Pizzini, Francesca Benedetta

    2016-08-01

    Cavernoma is a vascular hamartoma, which represents 10-20% of all central nervous system vascular malformations. The majority (80%) of them are supratentorial, while involvement of the cranial nerves and the optic pathways is extremely rare. The main clinical presentation of optochiasmatic cavernomas consists of chiasmatic apoplexy, which is a neurosurgical emergency. Here, we report a case in which the finding was incidentally detected in a 49-year-old man. We describe the imaging characteristics of the lesion in such a rare location, highlighting the role of magnetic resonance imaging (MRI) (specifically 3 Tesla) in the management of asymptomatic patients. PMID:27145992

  4. HRSC: High resolution stereo camera

    Neukum, G.; Jaumann, R.; Basilevsky, A.T.; Dumke, A.; Van Gasselt, S.; Giese, B.; Hauber, E.; Head, J. W., III; Heipke, C.; Hoekzema, N.; Hoffmann, H.; Greeley, R.; Gwinner, K.; Kirk, R.; Markiewicz, W.; McCord, T.B.; Michael, G.; Muller, Jan-Peter; Murray, J.B.; Oberst, J.; Pinet, P.; Pischel, R.; Roatsch, T.; Scholten, F.; Willner, K.

    2009-01-01

    The High Resolution Stereo Camera (HRSC) on Mars Express has delivered a wealth of image data, amounting to over 2.5 TB from the start of the mapping phase in January 2004 to September 2008. In that time, more than a third of Mars was covered at a resolution of 10-20 m/pixel in stereo and colour. After five years in orbit, HRSC is still in excellent shape, and it could continue to operate for many more years. HRSC has proven its ability to close the gap between the low-resolution Viking image data and the high-resolution Mars Orbiter Camera images, leading to a global picture of the geological evolution of Mars that is now much clearer than ever before. Derived highest-resolution terrain model data have closed major gaps and provided an unprecedented insight into the shape of the surface, which is paramount not only for surface analysis and geological interpretation, but also for combination with and analysis of data from other instruments, as well as in planning for future missions. This chapter presents the scientific output from data analysis and highlevel data processing, complemented by a summary of how the experiment is conducted by the HRSC team members working in geoscience, atmospheric science, photogrammetry and spectrophotometry. Many of these contributions have been or will be published in peer-reviewed journals and special issues. They form a cross-section of the scientific output, either by summarising the new geoscientific picture of Mars provided by HRSC or by detailing some of the topics of data analysis concerning photogrammetry, cartography and spectral data analysis.

  5. High resolution tomographic instrument development

    1992-08-01

    Our recent work has concentrated on the development of high-resolution PET instrumentation reflecting in part the growing importance of PET in nuclear medicine imaging. We have developed a number of positron imaging instruments and have the distinction that every instrument has been placed in operation and has had an extensive history of application for basic research and clinical study. The present program is a logical continuation of these earlier successes. PCR-I, a single ring positron tomograph was the first demonstration of analog coding using BGO. It employed 4 mm detectors and is currently being used for a wide range of biological studies. These are of immense importance in guiding the direction for future instruments. In particular, PCR-II, a volume sensitive positron tomograph with 3 mm spatial resolution has benefited greatly from the studies using PCR-I. PCR-II is currently in the final stages of assembly and testing and will shortly be placed in operation for imaging phantoms, animals and ultimately humans. Perhaps the most important finding resulting from our previous study is that resolution and sensitivity must be carefully balanced to achieve a practical high resolution system. PCR-II has been designed to have the detection characteristics required to achieve 3 mm resolution in human brain under practical imaging situations. The development of algorithms by the group headed by Dr. Chesler is based on a long history of prior study including his joint work with Drs. Pelc and Reiderer and Stearns. This body of expertise will be applied to the processing of data from PCR-II when it becomes operational.

  6. High resolution tomographic instrument development

    1992-01-01

    Our recent work has concentrated on the development of high-resolution PET instrumentation reflecting in part the growing importance of PET in nuclear medicine imaging. We have developed a number of positron imaging instruments and have the distinction that every instrument has been placed in operation and has had an extensive history of application for basic research and clinical study. The present program is a logical continuation of these earlier successes. PCR-I, a single ring positron tomograph was the first demonstration of analog coding using BGO. It employed 4 mm detectors and is currently being used for a wide range of biological studies. These are of immense importance in guiding the direction for future instruments. In particular, PCR-II, a volume sensitive positron tomograph with 3 mm spatial resolution has benefited greatly from the studies using PCR-I. PCR-II is currently in the final stages of assembly and testing and will shortly be placed in operation for imaging phantoms, animals and ultimately humans. Perhaps the most important finding resulting from our previous study is that resolution and sensitivity must be carefully balanced to achieve a practical high resolution system. PCR-II has been designed to have the detection characteristics required to achieve 3 mm resolution in human brain under practical imaging situations. The development of algorithms by the group headed by Dr. Chesler is based on a long history of prior study including his joint work with Drs. Pelc and Reiderer and Stearns. This body of expertise will be applied to the processing of data from PCR-II when it becomes operational.

  7. High resolution tomographic instrument development

    Our recent work has concentrated on the development of high-resolution PET instrumentation reflecting in part the growing importance of PET in nuclear medicine imaging. We have developed a number of positron imaging instruments and have the distinction that every instrument has been placed in operation and has had an extensive history of application for basic research and clinical study. The present program is a logical continuation of these earlier successes. PCR-I, a single ring positron tomograph was the first demonstration of analog coding using BGO. It employed 4 mm detectors and is currently being used for a wide range of biological studies. These are of immense importance in guiding the direction for future instruments. In particular, PCR-II, a volume sensitive positron tomograph with 3 mm spatial resolution has benefited greatly from the studies using PCR-I. PCR-II is currently in the final stages of assembly and testing and will shortly be placed in operation for imaging phantoms, animals and ultimately humans. Perhaps the most important finding resulting from our previous study is that resolution and sensitivity must be carefully balanced to achieve a practical high resolution system. PCR-II has been designed to have the detection characteristics required to achieve 3 mm resolution in human brain under practical imaging situations. The development of algorithms by the group headed by Dr. Chesler is based on a long history of prior study including his joint work with Drs. Pelc and Reiderer and Stearns. This body of expertise will be applied to the processing of data from PCR-II when it becomes operational

  8. Chemical exchange saturation transfer MR imaging of Parkinson's disease at 3 Tesla

    To demonstrate the feasibility of using chemical exchange saturation transfer (CEST) imaging to detect Parkinson's disease (PD) in patients at 3 Tesla. Twenty-seven PD patients (17 men and 10 women; age range, 54-77 years) and 22 age-matched normal controls (13 men and 9 women; age range, 55-73 years) were examined on a 3-Tesla MRI system. Magnetization transfer spectra with 31 different frequency offsets (-6 to 6 ppm) were acquired at two transverse slices of the head, including the basal ganglia and midbrain. One-way analysis of variance tests was used to compare the differences in CEST imaging signals between PD patients and normal controls. Total CEST signal between the offsets of 0 and 4 ppm in the substantia nigra was significantly lower in PD patients than in normal controls (P = 0.006), which could be associated with the loss of dopaminergic neurons. Protein-based CEST imaging signals at the offset of 3.5 ppm in the globus pallidus, putamen and caudate were significantly increased in PD patients, compared to normal controls (P < 0.001, P = 0.003, P < 0.001, respectively). CEST imaging signals could potentially serve as imaging biomarkers to aid in the non-invasive molecular diagnosis of PD. (orig.)

  9. Chemical exchange saturation transfer MR imaging of Parkinson's disease at 3 Tesla

    Li, Chunmei; Peng, Shuai; Wang, Rui; Chen, Min [Beijing Hospital, Department of Radiology, Beijing (China); Chen, Haibo; Su, Wen [Beijing Hospital, Department of Neurology, Beijing (China); Zhao, Xuna [Peking University, Center for MRI Research and Beijing City Key Lab for Medical Physics and Engineering, Beijing (China); Zhou, Jinyuan [Johns Hopkins University, Department of Radiology, Baltimore, MD (United States)

    2014-10-15

    To demonstrate the feasibility of using chemical exchange saturation transfer (CEST) imaging to detect Parkinson's disease (PD) in patients at 3 Tesla. Twenty-seven PD patients (17 men and 10 women; age range, 54-77 years) and 22 age-matched normal controls (13 men and 9 women; age range, 55-73 years) were examined on a 3-Tesla MRI system. Magnetization transfer spectra with 31 different frequency offsets (-6 to 6 ppm) were acquired at two transverse slices of the head, including the basal ganglia and midbrain. One-way analysis of variance tests was used to compare the differences in CEST imaging signals between PD patients and normal controls. Total CEST signal between the offsets of 0 and 4 ppm in the substantia nigra was significantly lower in PD patients than in normal controls (P = 0.006), which could be associated with the loss of dopaminergic neurons. Protein-based CEST imaging signals at the offset of 3.5 ppm in the globus pallidus, putamen and caudate were significantly increased in PD patients, compared to normal controls (P < 0.001, P = 0.003, P < 0.001, respectively). CEST imaging signals could potentially serve as imaging biomarkers to aid in the non-invasive molecular diagnosis of PD. (orig.)

  10. Section on High Resolution Optical Imaging (HROI)

    Federal Laboratory Consortium — The Section on High Resolution Optical Imaging (HROI) develops novel technologies for studying biological processes at unprecedented speed and resolution. Research...

  11. High-Resolution Imaging Spectrometer

    Dozier, Jeff; Goetz, Alexander F. H.

    1990-01-01

    Earth resources observed in greater detail. High-Resolution Imaging Spectrometer, undergoing development for use in NASA's Earth Observing System, measures reflectance of Earth's surface in visible and near-infrared wavelengths. From an orbit around Earth, instrument scans surface of Earth in 200 wavelength bands simultaneously. Produces images enabling identification of minerals in rocks and soils, important algal pigments in oceans and inland waters, changes in spectra associated with biochemistry of plant canopies, compositions of atmospheric aerosols, sizes of grains in snow, and contamination of snow by impurities that absorb visible light.

  12. Fast 3D T1-weighted brain imaging at 3 Tesla with modified 3D FLASH sequence

    Longitudinal relaxation times (T1) of white and gray matter become close at high magnetic field. Therefore, classical T1 sensitive methods, like spoiled FLASH fail to give a sufficient contrast in human brain imaging at 3 Tesla. An excellent T1 contrast can be achieved at high field by gradient echo imaging with a preparatory inversion pulse. The inversion recovery (IR) preparation can be combined with a fast 2D gradient echo scans. In this paper we present an application of this technique to rapid 3-dimensional imaging. New technique called 3D SIR FLASH was implemented on Burker MSLX system equipped with a 3T, 90 cm horizontal bore magnet working in Centre Hospitalier in Rouffach, France. The new technique was used for comparison of MRI images of healthy volunteers obtained with a traditional 3D imaging. White and gray matter are clearly distinguishable when 3D SIR FLASH is used. The total acquisition time for 128x128x128 image was 5 minutes. Three dimensional visualization with facet representation of surfaces and oblique sections was done off-line on the INDIGO Extreme workstation. New technique is widely used in FORENAP, Centre Hospitalier in Reuffach, Alsace. (author)

  13. The High Spectral Resolution Lidar

    Eloranta, E. W.; Roesler, F. L.; Sroga, J. T.

    1983-01-01

    The High Spectral Resolution Lidar (HSRL) system was developed for the remote measurement of atmospheric optical properties. Measurements are obtained by the separation of the backscattered signal into aerosol and molecular channels using a high spectral resolution Fabry-Perot optical interferometer to separate the aerosol contributions to backscatter near the laser wavelength from the Doppler-shifted molecular component of the backscatter. The transmitter consists of an optically pumped pulsed dye laser of the oscillator-amplifier design which emits at 467.88 nm, with a bandwidth of less than 0.3 pm. The transmitter and receiver share a common Schmidt-Cassegrain telescope, although they do not share the same field stop, but rather two conjugate stops. The HSRL system uses a computer-controlled dual-channel photon-counting data acquisition system providing for stable measurements at very low power levels and an excellent dynamic range. The system has been used to obtain airborne measurements of height profiles of aerosol and molecular backscatter cross sections.

  14. Testing of a 3 tesla superconducting magnet for the AMY detector at TRISTAN

    A 3 tesla magnet was constructed and installed in an experimental hall at TRISTAN. Cooldown and excitation tests of the magnet were carried out with a dedicated cryogenic system. The coil has a 2.39 m inner diameter and is 1.54 m long with a radial thickness of 0.1 m. The rated current is 5 kA and the stored energy is 40 MJ. The refrigerator and 17-ton magnet cold mass were cooled to 4.4 K in seven days. Then the magnet was energized to the design current of 5 kA and the mechanical stress of the coil supports was measured. The stress on the supports was well below the allowed maximum. Measurements of the discharge characteristics of the magnet confirmed that the magnet was stable and reliable

  15. Ultra-high resolution AMOLED

    Wacyk, Ihor; Prache, Olivier; Ghosh, Amal

    2011-06-01

    AMOLED microdisplays continue to show improvement in resolution and optical performance, enhancing their appeal for a broad range of near-eye applications such as night vision, simulation and training, situational awareness, augmented reality, medical imaging, and mobile video entertainment and gaming. eMagin's latest development of an HDTV+ resolution technology integrates an OLED pixel of 3.2 × 9.6 microns in size on a 0.18 micron CMOS backplane to deliver significant new functionality as well as the capability to implement a 1920×1200 microdisplay in a 0.86" diagonal area. In addition to the conventional matrix addressing circuitry, the HDTV+ display includes a very lowpower, low-voltage-differential-signaling (LVDS) serialized interface to minimize cable and connector size as well as electromagnetic emissions (EMI), an on-chip set of look-up-tables for digital gamma correction, and a novel pulsewidth- modulation (PWM) scheme that together with the standard analog control provides a total dimming range of 0.05cd/m2 to 2000cd/m2 in the monochrome version. The PWM function also enables an impulse drive mode of operation that significantly reduces motion artifacts in high speed scene changes. An internal 10-bit DAC ensures that a full 256 gamma-corrected gray levels are available across the entire dimming range, resulting in a measured dynamic range exceeding 20-bits. This device has been successfully tested for operation at frame rates ranging from 30Hz up to 85Hz. This paper describes the operational features and detailed optical and electrical test results for the new AMOLED WUXGA resolution microdisplay.

  16. Ventricular Assist Device implant (AB 5000) prototype cannula: In vitro assessment of MRI issues at 3-Tesla

    Valencerina Samuel; Shellock Frank G

    2008-01-01

    Abstract Purpose To evaluate MRI issues at 3-Tesla for a ventricular assist device (VAD). Methods The AB5000 Ventricle with a prototype Nitinol wire-reinforced In-Flow Cannula and Out-Flow Cannula attached (Abiomed, Inc., Danvers, MA) was evaluated for magnetic field interactions, heating, and artifacts at 3-Tesla. MRI-related heating was assessed with the device in a gelled-saline-filled, head/torso phantom using a transmit/received RF body coil while performing MRI at a whole body averaged ...

  17. A free-breathing non-contrast-enhanced pulmonary magnetic resonance angiography at 3 Tesla

    YANG Jian; WANG Wei; WANG Ya-rong; NIU Gang; JIN Chen-wang; WU Ed Xuekui

    2009-01-01

    Background The breathhold contrast-enhanced three-dimensional magnetic resonance angiography (MRA) using T1-weighted gradient-echo imaging sequence is the standard technique for MRA of the thorax. However, this technique is not desirable for certain patients with respiratory insufficiency, serious renal impairment, or allergy to contrast agents. The objective of this study was to optimize and evaluate a non-contrast-enhanced free-breathing pulmonary MRA protocol at 3 Tesla.Methods The time-of-flight protocol was based on a two-dimensional T1-weighted turbo field echo sequence with slice-selective inversion recovery and magnetization transfer preparation together with respiratory navigator gating, cardiac gating, and parallel imaging. Optimal values for time of inversion delay, flip angle and slice thickness were experimentally determined and used for all subjects.Results Excellent pulmonary MRA images, in which the 7th order branches of pulmonary arteries could be reliably identified, were obtained in the 12 free-breathing healthy volunteers. TI of ~300 ms provides the best suppression of background thoracic and cardiac muscles and effective inflow enhancement. With increasing flip angle, the pulmonary vessels gradually brightened and exhibited optimal contrast at 20°-30°. The 2 mm slice thickness and 0.5 mm slice overlap is suitable for visualization of the peripheral pulmonary vessel.Conclusions The MRA protocol at 3 Tesla may have clinical significance for pulmonary vascular imaging in patients who are not available for contrast-enhanced 3D MRA and CT angiography examination or are unable to sustain a long breath-hold.

  18. Oxygen-enhanced MRI of the lungs. Intraindividual comparison between 1.5 and 3 Tesla

    Purpose: To assess the feasibility of oxygen-enhanced MRI of the lung at 3 Tesla and to compare signal characteristics with 1.5 Tesla. Materials and Methods: 13 volunteers underwent oxygen-enhanced lung MRI at 1.5 and 3 T with a T 1-weighted single-slice non-selective inversion-recovery single-shot half-Fourier fast-spin-echo sequence with simultaneous respiratory and cardiac triggering in coronal orientation. 40 measurements were acquired during room air breathing and subsequently during oxygen breathing (15 L/min, close-fitting face-mask). The signal-to-noise ratio (SNR) of the lung tissue was determined with a difference image method. The image quality of all acquisitions was visually assessed. The mean values of the oxygen-induced relative signal enhancement and its regional coefficient of variation were calculated and the signal enhancement was displayed as color-coded parameter maps. Oxygen-enhancement maps were visually assessed with respect to the distribution and heterogeneity of the oxygen-related signal enhancement at both field strengths. Results: The mean relative signal enhancement due to oxygen breathing was 13 % (± 5.6 %) at 1.5 T and of 9.0 % (± 8.0 %) at 3 T. The regional coefficient of variation was significantly higher at 3 T. Visual and quantitative assessment of the enhancement maps showed considerably less homogeneous distribution of the signal enhancement at 3 T. The SNR was not significantly different but showed a trend to slightly higher values (increase of about 10 %) at 3 T. Conclusion: Oxygen-enhanced pulmonary MRI is feasible at 3 Tesla. However, signal enhancement is currently more heterogeneous and slightly lower at 3 T. (orig.)

  19. High resolution spectroscopy of nearby AGN

    Kaastra, J. S.

    2002-01-01

    In this paper the potential of high resolution spectroscopy of nearby AGN with XEUS is discussed. The focus is upon the energy resolution that is needed in order to disentangle the different spectral components. It is shown that there is an urgent need for high spectral resolution, and that a spectral resolution of 1 eV, if possible, leads to a significant increase in diagnostic power as compared to 2 eV resolution.

  20. Recurrent ulnar nerve entrapment at the elbow: Correlation of surgical findings and 3-Tesla magnetic resonance neurography

    Chhabra, Avneesh; Wadhwa, Vibhor; Thakkar, Rashmi S; John A Carrino; Dellon, A. Lee

    2013-01-01

    The authors describe the correlation between 3-Tesla magnetic resonance neurography (MRN) and surgical findings in two patients who underwent multiple previous failed ulnar nerve surgeries. MRN correctly localized the site of the abnormality. Prospectively observed MRN findings of perineural fibrosis, ulnar nerve re-entrapment abnormalities, medial antebrachial cutaneous neuroma and additional median nerve entrapment were confirmed surgically.

  1. Practising high-resolution anoscopy.

    Palefsky, Joel M

    2012-12-01

    The incidence of anal cancer is increasing in the general population among both men and women. The incidence is particularly high among men who have sex with men and HIV-infected men and women. Anal cancer is similar to cervical cancer and is associated with human papillomavirus (HPV). Anal cancer is potentially preventable through primary prevention with HPV vaccination or secondary prevention. Secondary prevention is modelled after cervical cancer, where cytology is used as a screening tool to identify women who need colposcopy. Colposcopy includes magnification of the cervix, which, along with acetic acid and Lugol's solution, is used to visualise and biopsy potentially precancerous lesions, enabling treatment before progression to cervical cancer. Anal cancer is likely preceded by high-grade anal intraepithelial neoplasia (HGAIN), and a colposcope with acetic acid and Lugol's solution may similarly be used to visualise HGAIN to permit biopsy and treatment in an effort to prevent anal cancer. To distinguish it from cervical colposcopy, this technique is called high-resolution anoscopy (HRA). Many of the features that distinguish low-grade AIN from HGAIN are similar to those of the cervix, but HRA poses several additional challenges compared with cervical colposcopy. These include uneven topography; obscuring of lesions due to haemorrhoids, folds, stool or mucus; or lesions being located at the base of folds and anal glands. Consequently, a long learning curve is typically required before becoming fully competent in this technique. The technique of HRA, its uses and challenges in prevention of anal cancer are described in this article. PMID:23380236

  2. Is the type and extent of hippocampal sclerosis measurable on high-resolution MRI?

    Urbach, H; Schwarzwald, R [Medical Center University of Freiburg, Dept. of Neuroradiology, Freiburg (Germany); Huppertz, H.J. [Swiss Epilepsy Center, Zurich (Switzerland); Becker, A.J. [Medical Center University of Bonn, Department of Neuropathology, Bonn (Germany); Wagner, J. [Medical Center University of Bonn, Department of Epileptology, Bonn (Germany); Bahri, M. Delsous; Tschampa, H.J. [Medical Center University of Bonn, Department of Radiology/Neuroradiology, Bonn (Germany)

    2014-09-15

    The purpose of this study is to relate hippocampal volume and FLAIR signal intensity to Wyler grading of hippocampal sclerosis (HS). Of 100 consecutive patients with temporal lobe epilepsy and HS as histopathological diagnosis, 32 had high-resolution 3 Tesla MRI and anatomically well-preserved hippocampi following amygdalo-hippocampectomy. Hippocampal volume on 3D T1-weighted gradient echo and signal intensity on coronal FLAIR sequences were determined using FreeSurfer and SPM tools and related to Wyler grading. Seizure outcome was determined after 1 year. Histopathology showed four Wyler II, 19 Wyler III, and 9 Wyler IV HS. Hippocampal volumes were 3.08 ml for Wyler II (Wyler II/contralateral side: p > 0.05), 2.19 ml for Wyler III (p < 0.01), 2.62 ml for Wyler IV (p = 0.01), and 3.08 ml for the contralateral side. Normalized FLAIR signals were 1,354 (p = 0.0004), 1,408 (p < 0.0001), 1,371 (p < 0.04), and 1,296, respectively. Wyler II hippocampi were visually normal. Two of four (50 %) Wyler II, 16/19 (84 %) Wyler III, and 6/9 (66 %) Wyler IV patients achieved Engel I outcome. Combined volumetry and quantitative FLAIR signal analysis clearly identifies Wyler III and IV HS. Quantitative FLAIR signal analysis may be helpful to identify Wyler II HS. (orig.)

  3. Is the type and extent of hippocampal sclerosis measurable on high-resolution MRI?

    The purpose of this study is to relate hippocampal volume and FLAIR signal intensity to Wyler grading of hippocampal sclerosis (HS). Of 100 consecutive patients with temporal lobe epilepsy and HS as histopathological diagnosis, 32 had high-resolution 3 Tesla MRI and anatomically well-preserved hippocampi following amygdalo-hippocampectomy. Hippocampal volume on 3D T1-weighted gradient echo and signal intensity on coronal FLAIR sequences were determined using FreeSurfer and SPM tools and related to Wyler grading. Seizure outcome was determined after 1 year. Histopathology showed four Wyler II, 19 Wyler III, and 9 Wyler IV HS. Hippocampal volumes were 3.08 ml for Wyler II (Wyler II/contralateral side: p > 0.05), 2.19 ml for Wyler III (p < 0.01), 2.62 ml for Wyler IV (p = 0.01), and 3.08 ml for the contralateral side. Normalized FLAIR signals were 1,354 (p = 0.0004), 1,408 (p < 0.0001), 1,371 (p < 0.04), and 1,296, respectively. Wyler II hippocampi were visually normal. Two of four (50 %) Wyler II, 16/19 (84 %) Wyler III, and 6/9 (66 %) Wyler IV patients achieved Engel I outcome. Combined volumetry and quantitative FLAIR signal analysis clearly identifies Wyler III and IV HS. Quantitative FLAIR signal analysis may be helpful to identify Wyler II HS. (orig.)

  4. Double-bundle depiction of the anterior cruciate ligament at 3 Tesla

    Magnetic resonance imaging on 3 Tesla (3T MRI) with arthroscopic correlation has proven to adequately identify the anteromedial bundle (AMB) and posterolateral bundle (PLB) in cadaver knees. The purpose of this study was to describe the depiction of ACL bundle anatomy on 3T MRI in daily practice. In a retrospective cohort study, we included 50 consecutive patients who underwent standard 3T MRI of the knee and had an intact ACL. Two musculoskeletal radiologists independently reviewed all scans for depiction of ACL bundle anatomy using standardized forms. Descriptive statistics were used. Twenty-three right knees (46%) and 27 left knees (54%) were included in the study. Mean age of the patients was 35 years (range 12 to 68 years); 37 patients were male (74%). ACL bundle anatomy was best depicted in the axial plane in 44 knees (88%) and in the coronal plane in six knees (12%). Two bundles were seen in 47 knees (94%). The AMB was completely seen in 45 knees (90%). The PLB was completely seen in 40 knees (80%). Both bundles were completely seen in 37 knees (76%). The double-bundle anatomy of the ACL is visualized in 94% of patients on 3T MRI. Because of potentially associated clinical benefits, we advocate to report separately on the anteromedial bundle and posterolateral bundle in case of anterior cruciate ligament injury of the knee. (orig.)

  5. Double-bundle depiction of the anterior cruciate ligament at 3 Tesla

    Adriaensen, M.E.A.P.M. [Atrium Medical Center Parkstad, Department of Radiology, Heerlen (Netherlands); Hogan, B. [Sports Surgery Clinic, Department of Radiology, Dublin (Ireland); Al-Bulushi, H.I.J. [Armed Forces Hospital, Department of Radiology, Muscat (Oman); Kavanagh, E.C. [Mater Misericordiae Hospital, Department of Radiology, Dublin (Ireland)

    2012-07-15

    Magnetic resonance imaging on 3 Tesla (3T MRI) with arthroscopic correlation has proven to adequately identify the anteromedial bundle (AMB) and posterolateral bundle (PLB) in cadaver knees. The purpose of this study was to describe the depiction of ACL bundle anatomy on 3T MRI in daily practice. In a retrospective cohort study, we included 50 consecutive patients who underwent standard 3T MRI of the knee and had an intact ACL. Two musculoskeletal radiologists independently reviewed all scans for depiction of ACL bundle anatomy using standardized forms. Descriptive statistics were used. Twenty-three right knees (46%) and 27 left knees (54%) were included in the study. Mean age of the patients was 35 years (range 12 to 68 years); 37 patients were male (74%). ACL bundle anatomy was best depicted in the axial plane in 44 knees (88%) and in the coronal plane in six knees (12%). Two bundles were seen in 47 knees (94%). The AMB was completely seen in 45 knees (90%). The PLB was completely seen in 40 knees (80%). Both bundles were completely seen in 37 knees (76%). The double-bundle anatomy of the ACL is visualized in 94% of patients on 3T MRI. Because of potentially associated clinical benefits, we advocate to report separately on the anteromedial bundle and posterolateral bundle in case of anterior cruciate ligament injury of the knee. (orig.)

  6. Accuracy of 3-Tesla MR and MR arthrography in diagnosis of meniscal retear in the post-operative knee

    This study assesses the accuracy of 3-Tesla (3-T) conventional MR imaging, 3-T MR arthrography, and the combined use of conventional MR and MR arthrography in the diagnosis of meniscal retears as compared with arthroscopy. The study also assess whether there are false-negative cases in which injected contrast does not extend into the meniscus despite a meniscal retear being seen on arthroscopy. One hundred consecutive knee MR arthrograms performed on patients with previous knee surgery were reviewed retrospectively. 3-T conventional MR imaging, 3-T MR arthrography, and the combined use of conventional MR and MR arthrography were assessed for meniscal retears as compared with arthroscopy. The criterion used to diagnose a meniscal retear on MR arthrogram was injected contrast tracking into the meniscus. All patients underwent second-look arthroscopy. Seventy-four patients had conventional MR findings consistent with a meniscal retear. In 83 of the 100 patients, intraarticular contrast helped in demonstrating a retear. In ten patients, there were MR findings consistent with a meniscal retear despite intra-articular contrast not tracking into the meniscus. Ninety-four of the 100 patients had meniscal retears on second-look arthroscopy. Three-Tesla conventional MR examination was 78 % sensitive and 75 % specific, MR arthrogram examination was 88 % sensitive and 100 % specific, and the combined use of MR and MR arthrogram imaging was 98 % sensitive and 75 % specific in the diagnosis of a meniscal retear. The combined use of 3-T MR and MR arthrography allows for high sensitivity and specificity in meniscal retear detection. In some patients, intraarticular contrast will not track into a meniscal retear. When MR findings are consistent with a meniscal retear but contrast does not extend into the meniscus, a meniscal retear is likely. (orig.)

  7. Optimized magnetic resonance sequences and parameters with operative assisted images for radical prostatectomy at 3 tesla-magnetic resonance image

    The objective of our study was to optimize magnetic resonance image (MRI) sequences and parameters using operative assisted images (three-dimensional images) for radical prostatectomy at 3 tesla (T) MRI. Five healthy volunteers underwent MRI on the 3.0 T scanner. Various sequences and parameters [Cube (echo time/repetition time (TE/TR)=18, 50, 90 ms/2000 ms), fast imaging employing steady state acquisition (FIESTA) (TE/TR/FA=2.4 ms/5 ms/40deg, 90deg), fast spoiled gradient recalled acquisition in the steady state (fSPGR) (TE/TR/FA=2.3 ms/11.2 ms/20deg), slice thickness=1.2 mm, matrix=192 x 160] were respectively compared. Several structures of the pelvis (the central zones and transition zones of the prostate, the peripheral zones of the prostate, seminal vesicles, rectum wall, bladder, muscle and fat) were determined. The signal intensities of these structures were measured on reformatted axial images and compared against several structures of the pelvis. Correlation with various sequences and parameters was based on the signal-to-noise ratio (SNR), the contrast ratio (CR) and the presence of artifacts. Student's t-test was used for statistical analysis. With Cube (TE/TR=50 ms/2000 ms), the average value of visual evaluation with artifacts was high, and SNR and CR were higher than for other sequence and parameters. Optimized MRI sequences and parameters were Cube (TE/TR=50 ms/2000 ms) which provides improved SNR and CR and the presence of artifacts with operative assisted images for radical prostatectomy. These operative assisted images obtained from Cube (TE/TR=50 ms/2000 ms) are likely to be useful for surgery. (author)

  8. Accuracy of 3-Tesla MR and MR arthrography in diagnosis of meniscal retear in the post-operative knee

    Magee, Thomas [NSI, Merritt Island, FL (United States); University of Central Florida School of Medicine, Orlando, FL (United States)

    2014-08-15

    This study assesses the accuracy of 3-Tesla (3-T) conventional MR imaging, 3-T MR arthrography, and the combined use of conventional MR and MR arthrography in the diagnosis of meniscal retears as compared with arthroscopy. The study also assess whether there are false-negative cases in which injected contrast does not extend into the meniscus despite a meniscal retear being seen on arthroscopy. One hundred consecutive knee MR arthrograms performed on patients with previous knee surgery were reviewed retrospectively. 3-T conventional MR imaging, 3-T MR arthrography, and the combined use of conventional MR and MR arthrography were assessed for meniscal retears as compared with arthroscopy. The criterion used to diagnose a meniscal retear on MR arthrogram was injected contrast tracking into the meniscus. All patients underwent second-look arthroscopy. Seventy-four patients had conventional MR findings consistent with a meniscal retear. In 83 of the 100 patients, intraarticular contrast helped in demonstrating a retear. In ten patients, there were MR findings consistent with a meniscal retear despite intra-articular contrast not tracking into the meniscus. Ninety-four of the 100 patients had meniscal retears on second-look arthroscopy. Three-Tesla conventional MR examination was 78 % sensitive and 75 % specific, MR arthrogram examination was 88 % sensitive and 100 % specific, and the combined use of MR and MR arthrogram imaging was 98 % sensitive and 75 % specific in the diagnosis of a meniscal retear. The combined use of 3-T MR and MR arthrography allows for high sensitivity and specificity in meniscal retear detection. In some patients, intraarticular contrast will not track into a meniscal retear. When MR findings are consistent with a meniscal retear but contrast does not extend into the meniscus, a meniscal retear is likely. (orig.)

  9. Sensitivity of an eight-element phased array coil in 3 Tesla MR imaging. A basic analysis

    The purpose of this study was to evaluate the performance advantages of an 8-element phased array head coil (8 ch coil) over a conventional quadrature-type birdcage head coil (QD coil) with regard to the signal-to-noise ratio (SNR) and image uniformity in 3 Tesla magnetic resonance (MR) imaging. We scanned a phantom filled with silicon oil using an 8 ch coil and a QD coil in a 3T MR imaging system and compared the SNR and image uniformity obtained from T1-weighted spin echo (SE) images and T2-weighted fast SE images between the 2 coils. We also visually evaluated images from 4 healthy volunteers. The SNR with the 8 ch coil was approximately twice that with the QD coil in the region of interest (ROI), which was set as 75% of the area in the center of the phantom images. With regard to the spatial variation of sensitivity, the SNR with the 8 ch coil was lower at the center of the images than at the periphery, whereas the SNR with the QD coil exhibited an inverse pattern. At the center of the images with the 8 ch coil, the SNR was somewhat lower, and that distribution was relatively flat compared to that in the periphery. Image uniformity varied less with the 8 ch coil than with the QD coil on both imaging sequences. The 8 ch phased array coil was useful for obtaining high quality 3T images because of its higher SNR and improved image uniformity than those obtained with conventional quadrature-type birdcage head coil. (author)

  10. High-resolution electron microscopy

    Spence, John C H

    2013-01-01

    This new fourth edition of the standard text on atomic-resolution transmission electron microscopy (TEM) retains previous material on the fundamentals of electron optics and aberration correction, linear imaging theory (including wave aberrations to fifth order) with partial coherence, and multiple-scattering theory. Also preserved are updated earlier sections on practical methods, with detailed step-by-step accounts of the procedures needed to obtain the highest quality images of atoms and molecules using a modern TEM or STEM electron microscope. Applications sections have been updated - these include the semiconductor industry, superconductor research, solid state chemistry and nanoscience, and metallurgy, mineralogy, condensed matter physics, materials science and material on cryo-electron microscopy for structural biology. New or expanded sections have been added on electron holography, aberration correction, field-emission guns, imaging filters, super-resolution methods, Ptychography, Ronchigrams, tomogr...

  11. Ventricular Assist Device implant (AB 5000 prototype cannula: In vitro assessment of MRI issues at 3-Tesla

    Valencerina Samuel

    2008-05-01

    Full Text Available Abstract Purpose To evaluate MRI issues at 3-Tesla for a ventricular assist device (VAD. Methods The AB5000 Ventricle with a prototype Nitinol wire-reinforced In-Flow Cannula and Out-Flow Cannula attached (Abiomed, Inc., Danvers, MA was evaluated for magnetic field interactions, heating, and artifacts at 3-Tesla. MRI-related heating was assessed with the device in a gelled-saline-filled, head/torso phantom using a transmit/received RF body coil while performing MRI at a whole body averaged SAR of 3-W/kg for 15-min. Artifacts were assessed for the main metallic component of this VAD (atrial cannula using T1-weighted, spin echo and gradient echo pulse sequences. Results The AB5000 Ventricle with the prototype In-Flow Cannula and Out-Flow Cannula attached showed relatively minor magnetic field interactions that will not cause movement in situ. Heating was not excessive (highest temperature change, +0.8°C. Artifacts may create issues for diagnostic imaging if the area of interest is in the same area or close to the implanted metallic component of this VAD (i.e., the venous cannula. Conclusion The results of this investigation demonstrated that it would be acceptable for a patient with this VAD (AB5000 Ventricle with a prototype Nitinol wire-reinforced In-Flow Cannula and Out-Flow Cannula attached to undergo MRI at 3-Tesla or less. Notably, it is likely that the operation console for this device requires positioning a suitable distance (beyond the 100 Gauss line or in the MR control room from the 3-Tesla MR system to ensure proper function of the VAD.

  12. Variations of the posterior cerebral artery diagnosed by MR angiography at 3 tesla

    Fenestration, early bifurcation, and duplication of the posterior cerebral artery (PCA) and the so-called hyperplastic anterior choroidal artery (AChA), considered a variation of the PCA, are rare. We evaluated the prevalence and characteristic features of these PCA variations on magnetic resonance (MR) angiography. We reviewed intracranial MR angiographic images of 2402 patients examined using a 3-tesla scanner. Images from the skull base to the intracranial region were obtained using the standard time-of-flight technique. We excluded images of 52 patients with insufficient image quality or occlusion of the PCA(s) and retrospectively evaluated the images of 2350 patients using a picture archiving and communication system. We observed PCA fenestration in eight (0.34 %) patients, most at the P1 segment and P1-P2 junction and all small in size, early bifurcation at the P1-P2 junction or proximal P2A segment in eight (0.34 %) patients, complete duplication in one patient, and hyperplastic AChA in 13 (0.55 %) patients. Eleven of the 13 hyperplastic AChAs supplied only the territory of the temporal branch of the PCA, and the remaining two supplied the entire territory of the PCA. We observed PCA variations in 30 (1.28 %) patients. We believe the name ''hyperplastic AChA'' inaccurately describes variations of the PCA in which the AChA supplies part of or all of the territory of the PCA and propose ''accessory PCA'' to describe an AChA that supplies part of the territory of the PCA or ''replaced PCA'' to describe that vessel that supplies the territory all branches of the PCA. (orig.)

  13. Variations of the posterior cerebral artery diagnosed by MR angiography at 3 tesla

    Uchino, Akira; Saito, Naoko; Takahashi, Masahiro; Okano, Nanami; Tanisaka, Megumi [Saitama Medical University International Medical Center, Department of Diagnostic Radiology, Hidaka, Saitama (Japan)

    2016-02-15

    Fenestration, early bifurcation, and duplication of the posterior cerebral artery (PCA) and the so-called hyperplastic anterior choroidal artery (AChA), considered a variation of the PCA, are rare. We evaluated the prevalence and characteristic features of these PCA variations on magnetic resonance (MR) angiography. We reviewed intracranial MR angiographic images of 2402 patients examined using a 3-tesla scanner. Images from the skull base to the intracranial region were obtained using the standard time-of-flight technique. We excluded images of 52 patients with insufficient image quality or occlusion of the PCA(s) and retrospectively evaluated the images of 2350 patients using a picture archiving and communication system. We observed PCA fenestration in eight (0.34 %) patients, most at the P1 segment and P1-P2 junction and all small in size, early bifurcation at the P1-P2 junction or proximal P2A segment in eight (0.34 %) patients, complete duplication in one patient, and hyperplastic AChA in 13 (0.55 %) patients. Eleven of the 13 hyperplastic AChAs supplied only the territory of the temporal branch of the PCA, and the remaining two supplied the entire territory of the PCA. We observed PCA variations in 30 (1.28 %) patients. We believe the name ''hyperplastic AChA'' inaccurately describes variations of the PCA in which the AChA supplies part of or all of the territory of the PCA and propose ''accessory PCA'' to describe an AChA that supplies part of the territory of the PCA or ''replaced PCA'' to describe that vessel that supplies the territory all branches of the PCA. (orig.)

  14. White Matter Brain Lesions in Midlife Familial Hypercholesterolemic Patients at 3-Tesla Magnetic Resonance Imaging

    Schmitz, S.A.; O' Regan, D.P.; Fitzpatrick, J.; Neuwirth, C.; Potter, E.; Tosi, I.; Hajnal, J.V.; Naoumova, R.P. (Imaging Sciences Dept. and Clinical Research Facility, MRC Clinical Sciences Centre, London (GB))

    2008-03-15

    Background: Patients with hypercholesterolemia of 60 years and older have an increased risk for white matter brain lesions and dementia. Purpose: To investigate whether patients with familial hypercholesterolemia (FH) develop white matter lesions at 3-Tesla (T) MRI as early as in midlife. Material and Methods: Non-diabetic, non-smoking, and non-hypertensive heterozygous FH patients on treatment with maximally tolerated dose of a statin for more than 5 years (n = 14) and matched controls (n = 22) aged 25 to 60 years of age were studied. Imaging was performed at 3T with a fluid-attenuated T2-weighted MR pulse sequence and a T1-weighted spin-echo pulse sequence following 10 ml of i.v. gadopentetate dimeglumine. Images were evaluated by two independent readers. Fasting blood samples were taken. Student's t test was employed at P<0.05. Results: Three volunteers and one FH patient had white matter lesions (P<0.53). No other evidence of past ischemic stroke was observed. Mean total serum cholesterol and low-density lipoprotein (LDL) cholesterol were significantly higher in the FH group (6.0+-1.1 vs. 5.1+-0.9 mmol/l, P<0.02 and 4.1+-0.9 vs. 3.1+-0.8 mmol/l, P<0.004, respectively). Conclusion: Heterozygous FH patients on statin treatment in the age range of 25 to 60 years are not at increased risk of white matter lesions at 3T MRI

  15. White Matter Brain Lesions in Midlife Familial Hypercholesterolemic Patients at 3-Tesla Magnetic Resonance Imaging

    Background: Patients with hypercholesterolemia of 60 years and older have an increased risk for white matter brain lesions and dementia. Purpose: To investigate whether patients with familial hypercholesterolemia (FH) develop white matter lesions at 3-Tesla (T) MRI as early as in midlife. Material and Methods: Non-diabetic, non-smoking, and non-hypertensive heterozygous FH patients on treatment with maximally tolerated dose of a statin for more than 5 years (n = 14) and matched controls (n = 22) aged 25 to 60 years of age were studied. Imaging was performed at 3T with a fluid-attenuated T2-weighted MR pulse sequence and a T1-weighted spin-echo pulse sequence following 10 ml of i.v. gadopentetate dimeglumine. Images were evaluated by two independent readers. Fasting blood samples were taken. Student's t test was employed at P<0.05. Results: Three volunteers and one FH patient had white matter lesions (P<0.53). No other evidence of past ischemic stroke was observed. Mean total serum cholesterol and low-density lipoprotein (LDL) cholesterol were significantly higher in the FH group (6.0±1.1 vs. 5.1±0.9 mmol/l, P<0.02 and 4.1±0.9 vs. 3.1±0.8 mmol/l, P<0.004, respectively). Conclusion: Heterozygous FH patients on statin treatment in the age range of 25 to 60 years are not at increased risk of white matter lesions at 3T MRI

  16. High Resolution Surface Resistance Studies

    Aull, S; Junginger, T; Knobloch, J

    2013-01-01

    CERNs Quadrupole Resonator enables sub-nΩ-resolution measurements of the surface resistance. Much more information about the RF performance is accessible compared to regular cavity measurements. In this contribution we show that the surface resistance decreases for low cooling rates. The design of the Quadrupole Resonator allows us to exclude the formation of niobium hydrides, the efficacy of the magnetic shielding and thermal currents as possible causes. We find that the expulsion of the residual ambient magnetic field as the cause of the reduction of the surface resistance is consistent with our results.

  17. High resolution magnetic spectrometer SHARAQ in RIBF

    For a new spectroscopy of nuclei using intense RI beams at RIBF, we started the SHARAQ project where a high-resolution SHARAQ spectrometer is being constructed together with a high-resolution secondary beam line. Physics motivation and the specification of the spectrometer are presented

  18. High Resolution PDF Measurements on Ag Nanoparticles

    Rocha, Túlio C. R.; Martin, Chris; Kycia, Stefan; Zanchet, Daniela

    2009-01-01

    The quantitative analysis of structural defects in Ag nanoparticles was addressed in this work. We performed atomic scale structural characterization by a combination of x-ray diffraction (XRD) using the Pair Distribution Function analysis (PDF) and High Resolution Transmission Electron Microscopy (HRTEM). The XRD measurements were performed using an innovative instrumentation setup to provide high resolution PDF patterns

  19. High-resolution beta imaging

    For many years, β radioactivity has been used to label molecules and follow them in various biological processes. β imaging is obtained by autoradiography. Classically made on films or on photographic emulsions, autoradiography is now supplanted by radio-imagers which are very performing. The phosphor-imager, β-imager and μ-imager are the systems mainly used today and their operating principles and properties are compared. The great advantages of these imagers are: their rapidity to obtain results and their reliability for absolute quantification. All emitters (β-, β- -γ and β+) are detectable as well as the gamma emitters of nuclear medicine, by means of their low energy electrons ejected during y emission. Phosphor-imager is well suited to energetic tracers and large series of experiments. Real time radio-imagers (β-imager and μ-imager) are preferred to verify experimental conditions. The β--imager and s-imager are often complementary: one with a large field of view and medium resolution, the other with a higher resolution, but a small surface of detection. Their numerous applications in molecular biology (blotting. gene expression) and in physiopathology (binding, in situ hybridization, immunohistochemistry) are well known. Today other applications are under development in molecular imaging. Moreover, the possibility of multi-detection opens new fields of investigations, especially in nuclear medicine. (author)

  20. High Resolution Silicon Deformable Mirrors Project

    National Aeronautics and Space Administration — This proposal describes a plan to build a prototype small stroke, high precision deformable mirror suitable for space-based operation in systems for high-resolution...

  1. High-Resolution Data for a Low-Resolution World

    Brady, Brendan Williams [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-05-10

    In the past 15 years, the upper section of Cañon de Valle has been severely altered by wildfires and subsequent runoff events. Loss of root structures on high-angle slopes results in debris flow and sediment accumulation in the narrow canyon bottom. The original intent of the study described here was to better understand the changes occurring in watershed soil elevations over the course of several post-fire years. An elevation dataset from 5 years post-Cerro Grande fire was compared to high-resolution LiDAR data from 14 years post-Cerro Grande fire (also 3 years post-Las Conchas fire). The following analysis was motivated by a problematic comparison of these datasets of unlike resolution, and therefore focuses on what the data reveals of itself. The objective of this study is to highlight the effects vegetation can have on remote sensing data that intends to read ground surface elevation.

  2. Assessment of MRI issues at 3-Tesla for metallic surgical implants: findings applied to 61 additional skin closure staples and vessel ligation clips

    Gill Amreeta; Shellock Frank G

    2012-01-01

    Abstract Purpose Metallic skin closure staples and vessel ligation clips should be tested at 3-Tesla to characterize MRI issues in order to ensure patient safety. Therefore, metallic surgical implants were assessed at 3-Tesla for magnetic field interactions, MRI-related heating, and artifacts. Methods A skin closure staple (Visistat Skin Stapler, staple, Polytetrafluoroethylene, PTFE, coated 316L/316LVM stainless steel; Teleflex Medical, Durham, NC) and a vessel ligation clip (Hemoclip Tradit...

  3. A 128-Channel Receive-Only Cardiac Coil for Highly Accelerated Cardiac MRI at 3 Tesla

    Schmitt, Melanie; Potthast, Andreas; Sosnovik, David E; Polimeni, Jonathan R; Wiggins, Graham C.; Triantafyllou, Christina; Wald, Lawrence L.

    2008-01-01

    A 128-channel receive-only array coil is described and tested for cardiac imaging at 3T. The coil is closely contoured to the body with a “clam-shell” geometry with 68 posterior and 60 anterior elements, each 75 mm in diameter, and arranged in a continuous overlapped array of hexagonal symmetry to minimize nearest neighbor coupling. Signal-to-noise ratio (SNR) and noise amplification for parallel imaging (G-factor) were evaluated in phantom and volunteer experiments. These results were compar...

  4. NOAA's Use of High-Resolution Imagery

    Hund, Erik

    2007-01-01

    NOAA's use of high-resolution imagery consists of: a) Shoreline mapping and nautical chart revision; b) Coastal land cover mapping; c) Benthic habitat mapping; d) Disaster response; and e) Imagery collection and support for coastal programs.

  5. High Resolution Silicon Deformable Mirrors Project

    National Aeronautics and Space Administration — In this proposal we describe a plan to build a deformable mirror suitable for space-based operation in systems for high-resolution imaging. The prototype DM will be...

  6. DESIR high resolution separator at GANIL, France

    Toprek Dragan; Kurtukian-Nieto Teresa

    2012-01-01

    A high-resolution separator for the SPIRAL2/DESIR project at GANIL has been designed. The extracted isotopes from SPIRAL2 will be transported to and cooled in a RFQ cooler yielding beams with very low transverse emittance and energy spread. These beams will then be accelerated to 60 keV and sent to a high-resolution mass separator where a specific isotope will be selected. The good beam properties extracted from the RFQ cooler will allow one to obtain a mass resolution of č26000 with th...

  7. A high resolution silicon beam telescope

    We describe the design and present the performances of a charged particle telescope used for high resolution silicon pixel developments. A telescope made of four x and four y single-sided silicon microstrip layers was built, providing an r.m.s. position resolution of 1 μm for high energy charged particles. A signal over noise ratio of 130 was achieved with minimum ionizing particles

  8. Smartphone microendoscopy for high resolution fluorescence imaging

    Hong, Xiangqian; Nagarajan, Vivek K.; Mugler, Dale H.; Yu, Bing

    2016-01-01

    High resolution optical endoscopes are increasingly used in diagnosis of various medical conditions of internal organs, such as the gastrointestinal tracts, but they are too expensive for use in resource-poor settings. On the other hand, smartphones with high resolution cameras and Internet access have become more affordable, enabling them to diffuse into most rural areas and developing countries in the past decade. In this letter we describe a smartphone microendoscope that can take fluoresc...

  9. Structure of high-resolution NMR spectra

    Corio, PL

    2012-01-01

    Structure of High-Resolution NMR Spectra provides the principles, theories, and mathematical and physical concepts of high-resolution nuclear magnetic resonance spectra.The book presents the elementary theory of magnetic resonance; the quantum mechanical theory of angular momentum; the general theory of steady state spectra; and multiple quantum transitions, double resonance and spin echo experiments.Physicists, chemists, and researchers will find the book a valuable reference text.

  10. Modeling of high resolution digital retinal imaging

    Cideciyan, Artur V.; Nagel, Joachim H.; Jacobson, Samuel G.

    1991-01-01

    High resolution digital images of the retina can be obtained by photography with a Zeiss fundus camera followed by digitization of the photographic slide with a high resolution scanner. A complete model of this imaging system is developed based on its four components; the eye, the camera, the film and the scanner. The actual and modeled step responses and system noise are compared to validate the model. A simulated retinal reflection is used to demonstrate the extent of information degradatio...

  11. Stellar population models at high spectral resolution

    Maraston, Claudia; Portsmouth, ICG-University of; Kingdom, United

    2011-01-01

    We present new, high-to-intermediate spectral resolution stellar population models, based on four popular libraries of empirical stellar spectra, namely Pickles, ELODIE, STELIB and MILES. These new models are the same as our previous models, but with higher resolution and based on empirical stellar spectra, while keeping other ingredients the same including the stellar energetics, the atmospheric parameters and the treatment of the Thermally-Pulsating Asymptotic Giant Branch and the Horizontal Branch morphology. We further compute very high resolution (R=20,000) models based on the theoretical stellar library MARCS which extends to the near-infrared. We therefore provide merged high resolution stellar population models, extending from ~1000 AA to 25,000 AA. We compare how these libraries perform in stellar population models and highlight spectral regions where discrepancies are found. We confirm our previous findings that the flux around the V-band is lower (in a normalised sense) in models based on empirical...

  12. Improving quality of arterial spin labeling MR imaging at 3 Tesla with a 32-channel coil and parallel imaging.

    Ferré, Jean-Christophe; Petr, Jan; Bannier, Elise; Barillot, Christian; Gauvrit, Jean-Yves

    2012-01-01

    PURPOSE: To compare 12-channel and 32-channel phased-array coils and to determine the optimal parallel imaging (PI) technique and factor for brain perfusion imaging using Pulsed Arterial Spin labeling (PASL) at 3 Tesla (T). MATERIALS AND METHODS: Twenty-seven healthy volunteers underwent 10 different PASL perfusion PICORE Q2TIPS scans at 3T using 12-channel and 32-channel coils without PI and with GRAPPA or mSENSE using factor 2. PI with factor 3 and 4 were used only with the 32-channel coil....

  13. Single-row vs. double-row arthroscopic rotator cuff repair: clinical and 3 Tesla MR arthrography results

    Tudisco Cosimo

    2013-01-01

    Full Text Available Abstract Background Arthroscopic rotator cuff repair has become popular in the last few years because it avoids large skin incisions and deltoid detachment and dysfunction. Earlier arthroscopic single-row (SR repair methods achieved only partial restoration of the original footprint of the tendons of the rotator cuff, while double-row (DR repair methods presented many biomechanical advantages and higher rates of tendon-to-bone healing. However, DR repair failed to demonstrate better clinical results than SR repair in clinical trials. MR imaging at 3 Tesla, especially with intra-articular contrast medium (MRA, showed a better diagnostic performance than 1.5 Tesla in the musculoskeletal setting. The objective of this study was to retrospectively evaluate the clinical and 3 Tesla MRA results in two groups of patients operated on for a medium-sized full-thickness rotator cuff tear with two different techniques. Methods The first group consisted of 20 patients operated on with the SR technique; the second group consisted of 20 patients operated on with the DR technique. All patients were evaluated at a minimum of 3 years after surgery. The primary end point was the re-tear rate at 3 Tesla MRA. The secondary end points were the Constant-Murley Scale (CMS, the Simple Shoulder Test (SST scores, surgical time and implant expense. Results The mean follow-up was 40 months in the SR group and 38.9 months in the DR group. The mean postoperative CMS was 70 in the SR group and 68 in the DR group. The mean SST score was 9.4 in the SR group and 10.1 in the DR group. The re-tear rate was 60% in the SR group and 25% in the DR group. Leakage of the contrast medium was observed in all patients. Conclusions To the best of our knowledge, this is the first report on 3 Tesla MRA in the evaluation of two different techniques of rotator cuff repair. DR repair resulted in a statistically significant lower re-tear rate, with longer surgical time and higher implant

  14. Design of modern high resolution magnetic spectrometers

    The choice of correcting nonlinear aberrations in high resolution magnetic spectrometers with software or hardware is examined. The ability of raytracing methods, using realistic focal plane detector resolutions, is demonstrated for the S800 spectrograph under construction at the National Superconducting Cyclotron Laboratory (NSCL). Furthermore, Differential Algebraic methods are shown to reproduce the results for accurately known fields at a considerable savings in design time. (Author)

  15. Hip imaging of avascular necrosis at 7 Tesla compared with 3 Tesla

    To compare ultra-high field, high-resolution bilateral magnetic resonance imaging (MRI) of the hips at 7 Tesla (T) with 3 T MRI in patients with avascular necrosis (AVN) of the femoral head by subjective image evaluations, contrast measurements, and evaluation of the appearance of imaging abnormalities. Thirteen subjects with avascular necrosis treated using advanced core decompression underwent MRI at both 7 T and 3 T. Sequence parameters as well as resolution were kept identical for both field strengths. All MR images (MEDIC, DESS, PD/T2w TSE, T1w TSE, and STIR) were evaluated by two radiologists with regard to subjective image quality, soft tissue contrasts, B1 homogeneity (four-point scale, higher values indicating better image quality) and depiction of imaging abnormalities of the femoral heads (three-point scale, higher values indicating the superiority of 7 T). Contrast ratios of soft tissues were calculated and compared with subjective data. 7-T imaging of the femoral joints, as well as 3-T imaging, achieved ''good'' to ''very good'' quality in all sequences. 7 T showed significantly higher soft tissue contrasts for T2w and MEDIC compared with 3 T (cartilage/fluid: 2.9 vs 2.2 and 3.6 vs 2.6), better detailed resolution for cartilage defects (PDw, T2w, T1w, MEDIC, DESS > 2.5) and better visibility of joint effusions (MEDIC 2.6; PDw/T2w 2.4; DESS 2.2). Image homogeneity compared with 3 T (3.9-4.0 for all sequences) was degraded, especially in TSE sequences at 7 T through signal variations (7 T: 2.1-2.9); to a lesser extent also GRE sequences (7 T: 2.9-3.5). Imaging findings related to untreated or treated AVN were better delineated at 3 T (≤1.8), while joint effusions (2.2-2.6) and cartilage defects (2.5-3.0) were better visualized at 7 T. STIR performed much more poorly at 7 T, generating large contrast variations (1.5). 7-T hip MRI showed comparable results in hip joint imaging compared with 3 T with slight advantages in contrast detail (cartilage defects

  16. Hip imaging of avascular necrosis at 7 Tesla compared with 3 Tesla

    Theysohn, J.M.; Kraff, O.; Theysohn, N.; Orzada, S.; Lauenstein, T.C. [University Duisburg-Essen, Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany); University Hospital Essen, Institute for Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Landgraeber, S. [University Hospital Essen, Department of Orthopedic Surgery, Essen (Germany); Ladd, M.E. [University Duisburg-Essen, Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany); German Cancer Research Center, Department of Medical Physics in Radiology, Heidelberg (Germany)

    2014-05-15

    To compare ultra-high field, high-resolution bilateral magnetic resonance imaging (MRI) of the hips at 7 Tesla (T) with 3 T MRI in patients with avascular necrosis (AVN) of the femoral head by subjective image evaluations, contrast measurements, and evaluation of the appearance of imaging abnormalities. Thirteen subjects with avascular necrosis treated using advanced core decompression underwent MRI at both 7 T and 3 T. Sequence parameters as well as resolution were kept identical for both field strengths. All MR images (MEDIC, DESS, PD/T2w TSE, T1w TSE, and STIR) were evaluated by two radiologists with regard to subjective image quality, soft tissue contrasts, B1 homogeneity (four-point scale, higher values indicating better image quality) and depiction of imaging abnormalities of the femoral heads (three-point scale, higher values indicating the superiority of 7 T). Contrast ratios of soft tissues were calculated and compared with subjective data. 7-T imaging of the femoral joints, as well as 3-T imaging, achieved ''good'' to ''very good'' quality in all sequences. 7 T showed significantly higher soft tissue contrasts for T2w and MEDIC compared with 3 T (cartilage/fluid: 2.9 vs 2.2 and 3.6 vs 2.6), better detailed resolution for cartilage defects (PDw, T2w, T1w, MEDIC, DESS > 2.5) and better visibility of joint effusions (MEDIC 2.6; PDw/T2w 2.4; DESS 2.2). Image homogeneity compared with 3 T (3.9-4.0 for all sequences) was degraded, especially in TSE sequences at 7 T through signal variations (7 T: 2.1-2.9); to a lesser extent also GRE sequences (7 T: 2.9-3.5). Imaging findings related to untreated or treated AVN were better delineated at 3 T (≤1.8), while joint effusions (2.2-2.6) and cartilage defects (2.5-3.0) were better visualized at 7 T. STIR performed much more poorly at 7 T, generating large contrast variations (1.5). 7-T hip MRI showed comparable results in hip joint imaging compared with 3 T with slight

  17. High resolution energy analysers for the 'High Throughput Inelastic Spectrometer'

    Calculations of energy transfer resolution and count rate for different filter materials and various high resolution energy analysers for the 'High Throughput Inelastic Spectrometer', HTIS, on the SNS, are presented. A graphite filter is shown to be complementary to the existing beryllium filter analyser, improving the energy transfer resolution for energy transfers < approximately equal to 50 meV. Narrow energy band pass analysers are shown to be limited in energy transfer resolution by variations in the scattered flight path, rather than by the intrinsic band widths. The Be/MgO difference filter provides improved energy transfer resolution and high count rates over a wide range of energy transfers, and is felt to be the most appropriate high resolution energy analyser for HTIS. (author)

  18. High-Resolution PET Detector. Final report

    Karp, Joel

    2014-03-26

    The objective of this project was to develop an understanding of the limits of performance for a high resolution PET detector using an approach based on continuous scintillation crystals rather than pixelated crystals. The overall goal was to design a high-resolution detector, which requires both high spatial resolution and high sensitivity for 511 keV gammas. Continuous scintillation detectors (Anger cameras) have been used extensively for both single-photon and PET scanners, however, these instruments were based on NaI(Tl) scintillators using relatively large, individual photo-multipliers. In this project we investigated the potential of this type of detector technology to achieve higher spatial resolution through the use of improved scintillator materials and photo-sensors, and modification of the detector surface to optimize the light response function.We achieved an average spatial resolution of 3-mm for a 25-mm thick, LYSO continuous detector using a maximum likelihood position algorithm and shallow slots cut into the entrance surface.

  19. High-Resolution PET Detector. Final report

    The objective of this project was to develop an understanding of the limits of performance for a high resolution PET detector using an approach based on continuous scintillation crystals rather than pixelated crystals. The overall goal was to design a high-resolution detector, which requires both high spatial resolution and high sensitivity for 511 keV gammas. Continuous scintillation detectors (Anger cameras) have been used extensively for both single-photon and PET scanners, however, these instruments were based on NaI(Tl) scintillators using relatively large, individual photo-multipliers. In this project we investigated the potential of this type of detector technology to achieve higher spatial resolution through the use of improved scintillator materials and photo-sensors, and modification of the detector surface to optimize the light response function.We achieved an average spatial resolution of 3-mm for a 25-mm thick, LYSO continuous detector using a maximum likelihood position algorithm and shallow slots cut into the entrance surface

  20. High-resolution multi-slice PET

    This report evaluates the progress to test the feasibility and to initiate the design of a high resolution multi-slice PET system. The following specific areas were evaluated: detector development and testing; electronics configuration and design; mechanical design; and system simulation. The design and construction of a multiple-slice, high-resolution positron tomograph will provide substantial improvements in the accuracy and reproducibility of measurements of the distribution of activity concentrations in the brain. The range of functional brain research and our understanding of local brain function will be greatly extended when the development of this instrumentation is completed

  1. ELECTRONICS UPGRADE OF HIGH RESOLUTION MASS SPECTROMETERS

    Mcintosh, J; Joe Cordaro, J

    2008-03-10

    High resolution mass spectrometers are specialized systems that allow researchers to determine the exact mass of samples to four significant digits by using magnetic and electronic sector mass analyzers. Many of the systems in use today at research laboratories and universities were designed and built more than two decades ago. The manufacturers of these systems have abandoned the support for some of the mass spectrometers and parts to power and control them have become scarce or obsolete. The Savannah River National Laboratory has been involved in the upgrade of the electronics and software for these legacy machines. The Electronics Upgrade of High Resolution Mass Spectrometers consists of assembling high-end commercial instrumentation from reputable manufacturers with a minimal amount of customization to replace the electronics for the older systems. By taking advantage of advances in instrumentation, precise magnet control can be achieved using high resolution current sources and continuous feedback from a high resolution hall-effect probe. The custom equipment include a precision voltage divider/summing amplifier chassis, high voltage power supply chassis and a chassis for controlling the voltage emission for the mass spectrometer source tube. The upgrade package is versatile enough to interface with valve control, vacuum and other instrumentation. Instrument communication is via a combination of Ethernet and traditional IEEE-488 GPIB protocols. The system software upgrades include precision control, feedback and spectral waveform analysis tools.

  2. Smartphone microendoscopy for high resolution fluorescence imaging

    Hong, Xiangqian; Mugler, Dale H; Yu, Bing

    2016-01-01

    High resolution optical endoscopes are increasingly used in diagnosis of various medical conditions of internal organs, such as the gastrointestinal tracts, but they are too expensive for use in resource-poor settings. On the other hand, smartphones with high resolution cameras and Internet access have become more affordable, enabling them to diffuse into most rural areas and developing countries in the past decade. In this letter we describe a smartphone microendoscope that can take fluorescence images with a spatial resolution of 3.1 {\\mu}m. Images collected from ex vivo, in vitro and in vivo samples using the device are also presented. The compact and cost-effective smartphone microendoscope may be envisaged as a powerful tool for detecting pre-cancerous lesions of internal organs in low and middle income countries.

  3. High resolution LIDAR Thomson scattering at JET

    A high resolution LIDAR Thomson scattering system for JET has been designed, using a streak camera detection system. The best achievable spatial resolution of the existing LIDAR system is 9-10 cm. There is a need for higher resolution than is presently achievable in order to resolve the density and pressure gradients at the plasma edge during H-mode operation of JET. An additional motivation is the possibility of taking high resolution LIDAR snapshots of islands in the core of the plasma. It has been reported that by using a streak camera system, resolution of better than 4 cm is in principal possible, over a limited part of the plasma radius. Some feasibility experiments were carried out during a portion of the last JET period of operations (1:9:90 - 3:11:90). A Hadland 675 Imacon streak camera and 50/40 intensifier formed the detection system, and a Tektronix DCS digitizing CCD camera system recorded the data and transferred it to a PC for analysis. Results obtained on the stray light signature, plasma light levels and our initial attempts to record scattering results are reported here. In addition, some general problems encountered in the operation of the detection system and the interpretation of data are discussed. (author). 3 refs, 8 figs

  4. The future of high resolution electron microscopy

    D Van Dyck

    2000-01-01

    The state of the art and the future in quantitative high resolution electron microscopy are discussed in the framework of parameter estimation. Reconstruction methods are then to be considered as direct methods to yield a starting structure for further refinement. With the increasing flexibility of the instruments, computer aided experimental strategy will become important.

  5. Novel high resolution tactile robotic fingertips

    Drimus, Alin; Jankovics, Vince; Gorsic, Matija; Mátéfi-Tempfli, Stefan

    This paper describes a novel robotic fingertip based on piezoresistive rubber that can sense pressure tactile stimuli with a high spatial resolution over curved surfaces. The working principle is based on a three-layer sandwich structure (conductive electrodes on top and bottom and piezoresistive...

  6. A High-Resolution Stopwatch for Cents

    Gingl, Z.; Kopasz, K.

    2011-01-01

    A very low-cost, easy-to-make stopwatch is presented to support various experiments in mechanics. The high-resolution stopwatch is based on two photodetectors connected directly to the microphone input of a sound card. Dedicated free open-source software has been developed and made available to download. The efficiency is demonstrated by a free…

  7. High resolution CT in diffuse lung disease

    High resolution CT (computerized tomography) was discussed in detail. The conclusions were HRCT is able to define lung anatomy at the secondary lobular level and define a variety of abnormalities in patients with diffuse lung diseases. Evidence from numerous studies indicates that HRCT can play a major role in the assessment of diffuse infiltrative lung disease and is indicate clinically (95 refs.)

  8. Ion traps for high resolution spectroscopy

    As applications of ion traps, direct mass measurement and laser spectroscopy are reported. The advantages of ion traps for high resolution spectroscopy are mentioned. Double resonance method for hfs measurement and problems on ion injection into trap are explained. The planning of laser and microwave spectroscopy, using an ion trap and ISOL at Tohoku cyclotron, is described. (author)

  9. Compressive sensing for high resolution radar imaging

    Anitori, L.; Otten, M.P.G.; Hoogeboom, P.

    2010-01-01

    In this paper we present some preliminary results on the application of Compressive Sensing (CS) to high resolution radar imaging. CS is a recently developed theory which allows reconstruction of sparse signals with a number of measurements much lower than what is required by the Shannon sampling th

  10. High-resolution display system for mammograms

    Moskowitz, Michael J.; Huang, H. K.; Wang, Jun; Allen, Jeffrey; Sickles, Edward A.; Giles, Anthony

    1995-04-01

    A high resolution mammographic display station is implemented for clinical diagnosis and for a digital teaching file. The display consists of a specially designed, high resolution mammographic station which contains a connection to a 50 micron (variable spot size) laser film digitizer, two 2 K X 2.5 K display monitors, an image processor, a host computer, and a disk array for high speed image transfer to the display monitors. After digitization on a separate host computer, the files are immediately transferred to the display station and post- processed for viewing. The algorithm for post-processing of the digitized image applies a non- linear LUT to mimic the original film characteristics while taking into account the luminosity of the display monitors in an attempt to produce the highest digital image quality possible. Image processing functions for enhancing calcification and soft tissue are also available to assist the human observer in classification of objects within the image. Windowing and level controls are seamlessly integrated for each monitor, as well as magnification capabilities. For an image display at its full resolution (e.g., digitized at 100 microns), the magnification is accomplished with a roaming window utilizing simple 2X pixel replication. This has been found to be acceptable in preliminary tests with clinicians. Measurements of features on the 2 k displays are possible, as well. The display format accurately simulates mammographic viewing arrangements with automatic side-by-side historical, current, left and right craniocaudal, mediolateral, etc., view comparisons. This high resolution mammographic display is found to be essential for fast and accurate display of high resolution digitized mammograms. A digital mammographic teaching file has been designed and tested using this display architecture. The teaching file presents the case questions on the host display monitor, and the related images for each question are presented on the high

  11. Detectors for high resolution dynamic pet

    This report reviews the motivation for high spatial resolution in dynamic positron emission tomography of the head and the technical problems in realizing this objective. We present recent progress in using small silicon photodiodes to measure the energy deposited by 511 keV photons in small BGO crystals with an energy resolution of 9.4% full-width at half-maximum. In conjunction with a suitable phototube coupled to a group of crystals, the photodiode signal to noise ratio is sufficient for the identification of individual crystals both for conventional and time-of-flight positron tomography

  12. High resolution X-ray micro calorimeters

    Recently we have produced X-ray micro calorimeters with resolving powers approaching 2000 at 5.9keV using a spare XRS microcalorimeter array. In these experiments, we attached 400μm square, 8μm thick HgTe absorbers using a variety of attachment methods to an XRS array and tested the detector array at temperatures between 40 and 60mK. The best results were for absorbers attached using the standard XRS absorber-pixel thermal isolation scheme utilizing SU-8 polymer tubes. In this scenario we achieved a resolution of 3.2eV FWHM at 5.9keV. Substituting a silicon spacer for the SU-8 tubes also yielded sub-5eV results. In contrast, absorbers attached directly to the thermistor produced significant position dependence and thus degraded resolution. We discuss these new high resolution results, the various absorber attachment schemes, and planned future improvements

  13. CONSTRUCTING A WISE HIGH RESOLUTION GALAXY ATLAS

    After eight months of continuous observations, the Wide-field Infrared Survey Explorer (WISE) mapped the entire sky at 3.4 μm, 4.6 μm, 12 μm, and 22 μm. We have begun a dedicated WISE High Resolution Galaxy Atlas project to fully characterize large, nearby galaxies and produce a legacy image atlas and source catalog. Here we summarize the deconvolution techniques used to significantly improve the spatial resolution of WISE imaging, specifically designed to study the internal anatomy of nearby galaxies. As a case study, we present results for the galaxy NGC 1566, comparing the WISE enhanced-resolution image processing to that of Spitzer, Galaxy Evolution Explorer, and ground-based imaging. This is the first paper in a two-part series; results for a larger sample of nearby galaxies are presented in the second paper.

  14. A high resolution TOF diffractometer and spectrometer

    A combined high resolution TOF-diffractometer and -spectrometer is proposed for the new Munich reactor FRM II. The setup consists of a back scattering detector for the diffractometer and analyser crystals around the sample for the spectrometer (similar to IRIS from ISIS). The instrument uses a time of flight monochromator with a long flight path and a fast first chopper. The resolution of the diffractometer will be Δd/d ∼ 2 x 10-4 and the best energy resolution of the spectrometer will be 1-2 μeV with a silicon analyser system in near back scattering geometry. The dynamic range of the silicon system will be 110 μeV, but it can be shifted with the TOF monochromator in the range of several meV. With a second analyser system of graphite out of back scattering the energy resolution of the secondary spectrometer can be relaxed. One of the main applications of the diffractometer may be line shifts and line shape modifications relating to defect structures in crystals. The spectrometer opens up the possibility of inelastic measurements with μeV resolution and the investigation of diffusion and relaxation from ns to ps in one instrument. (author)

  15. Development of a high resolution and high dispersion Thomson parabola

    Jung, D.; Hörlein, R.; Kiefer, D.; Letzring, S.; Gautier, D. C.; Schramm, U.; Hübsch, C.; Öhm, R.; Albright, B. J.; Fernandez, J. C.; Habs, D.; Hegelich, B. M.

    2011-01-01

    Here, we report on the development of a novel high resolution and high dispersion Thomson parabola for simultaneously resolving protons and low-Z ions of more than 100 MeV/nucleon necessary to explore novel laser ion acceleration schemes. High electric and magnetic fields enable energy resolutions of ΔE/E Thomson parabola for ion energies of more than 30 MeV/nucleon.

  16. High resolution 3D nonlinear integrated inversion

    Li Yong; Wang Xuben; Li Zhirong; Li Qiong; Li Zhengwen

    2009-01-01

    The high resolution 3D nonlinear integrated inversion method is based on nonlinear theory. Under layer control, the log data from several wells (or all wells) in the study area and seismic trace data adjacent to the wells are input to a network with multiple inputs and outputs and are integratedly trained to obtain an adaptive weight function of the entire study area. Integrated nonlinear mapping relationships are built and updated by the lateral and vertical geologic variations of the reservoirs. Therefore, the inversion process and its inversion results can be constrained and controlled and a stable seismic inversion section with high resolution with velocity inversion, impedance inversion, and density inversion sections, can be gained. Good geologic effects have been obtained in model computation tests and real data processing, which verified that this method has high precision, good practicality, and can be used for quantitative reservoir analysis.

  17. Wavefront metrology for high resolution optical systems

    Miyakawa, Ryan H.

    Next generation extreme ultraviolet (EUV) optical systems are moving to higher resolution optics to accommodate smaller length scales targeted by the semiconductor industry. As the numerical apertures (NA) of the optics become larger, it becomes increasingly difficult to characterize aberrations due to experimental challenges associated with high-resolution spatial filters and geometrical effects caused by large incident angles of the test wavefront. This dissertation focuses on two methods of wavefront metrology for high resolution optical systems. The first method, lateral shearing interferometry (LSI), is a self-referencing interferometry where the test wavefront is incident on a low spatial frequency grating, and the resulting interference between the diffracted orders is used to reconstruct the wavefront aberrations. LSI has many advantages over other interferometric tests such as phase-shifting point diffraction interferometry (PS/PDI) due to its experimental simplicity, stability, relaxed coherence requirements, and its ability to scale to high numerical apertures. While LSI has historically been a qualitative test, this dissertation presents a novel quantitative investigation of the LSI interferogram. The analysis reveals the existence of systematic aberrations due to the nonlinear angular response from the diffraction grating that compromises the accuracy of LSI at medium to high NAs. In the medium NA regime (0.15 astigmatism term that scales as the square of the grating defocus. In the high NA regime (0.35 astigmatism aberrations to within lambda/20 rms.

  18. Superconducting High Resolution Fast-Neutron Spectrometers

    Hau, I D

    2006-05-25

    Superconducting high resolution fast-neutron calorimetric spectrometers based on {sup 6}LiF and TiB{sub 2} absorbers have been developed. These novel cryogenic spectrometers measure the temperature rise produced in exothermal (n, {alpha}) reactions with fast neutrons in {sup 6}Li and {sup 10}B-loaded materials with heat capacity C operating at temperatures T close to 0.1 K. Temperature variations on the order of 0.5 mK are measured with a Mo/Cu thin film multilayer operated in the transition region between its superconducting and its normal state. The advantage of calorimetry for high resolution spectroscopy is due to the small phonon excitation energies k{sub B}T on the order of {mu}eV that serve as signal carriers, resulting in an energy resolution {Delta}E {approx} (k{sub B}T{sup 2}C){sup 1/2}, which can be well below 10 keV. An energy resolution of 5.5 keV has been obtained with a Mo/Cu superconducting sensor and a TiB{sub 2} absorber using thermal neutrons from a {sup 252}Cf neutron source. This resolution is sufficient to observe the effect of recoil nuclei broadening in neutron spectra, which has been related to the lifetime of the first excited state in {sup 7}Li. Fast-neutron spectra obtained with a {sup 6}Li-enriched LiF absorber show an energy resolution of 16 keV FWHM, and a response in agreement with the {sup 6}Li(n, {alpha}){sup 3}H reaction cross section and Monte Carlo simulations for energies up to several MeV. The energy resolution of order of a few keV makes this novel instrument applicable to fast-neutron transmission spectroscopy based on the unique elemental signature provided by the neutron absorption and scattering resonances. The optimization of the energy resolution based on analytical and numerical models of the detector response is discussed in the context of these applications.

  19. Neuromelanin imaging of the substantia nigra and locus ceruleus among patients with Parkinson's disease using 3Tesla MRI

    Parkinson's disease (PD) is a progressive neurodegenerative disorder in which loss of dopaminergic neurons from the pars compacta of substantia nigra (SNc) and locus ceruleus (LC) in the major pathologic substrate. To investigate the relationships between the loss of SNc and LC neurons, and the stage of illness, we compared the signal intensity of SNc and LC between PD patients and normal controls by using a neuromelanin-sensitive magnetic resonance imaging (MRI) at 3 Tesla. We examined 41 PD patients in early stage, 10 in progressive stage, and 22 healthy controls. In PD, we observed a significant loss of neuromelanin in LC (p<0.0001) and lateral area of SNc (p=0.0011) while no significant difference between neuromelanin imaging and severity of PD was observed. The present study suggests that neuromelanin imaging using 3T MRI is a useful tool for early diagnosis of Parkinson's disease. (author)

  20. Quantitative assessment of right ventricular function and pulmonary regurgitation in surgically repaired tetralogy of Fallot using 256-slice CT: comparison with 3-Tesla MRI

    Yamasaki, Yuzo; Yonezawa, Masato; Matsuo, Yoshio; Kamitani, Takeshi; Higuchi, Ko; Honda, Hiroshi [Graduate School of Medical Sciences, Kyushu University, Department of Clinical Radiology, Higashi-ku, Fukuoka (Japan); Nagao, Michinobu; Kawanami, Satoshi [Graduate School of Medical Sciences, Kyushu University, Department of Molecular Imaging and Diagnosis, Higashi-ku, Fukuoka (Japan); Yamamura, Kenichiro [Graduate School of Medical Sciences, Kyushu University, Department of Pediatrics, Higashi-ku, Fukuoka (Japan); Sakamoto, Ichiro [Graduate School of Medical Sciences, Kyushu University, Department of Cardiovascular Medicine, Higashi-ku, Fukuoka (Japan); Shiokawa, Yuichi [Graduate School of Medical Sciences, Kyushu University, Department of Cardiovascular Surgery, Higashi-ku, Fukuoka (Japan); Yabuuchi, Hidetake [Graduate School of Medical Sciences, Kyushu University, Department of Health Sciences, Higashi-ku, Fukuoka (Japan)

    2014-12-15

    To compare 256-slice cardiac computed tomography (CCT) with cardiac magnetic resonance (CMR) imaging to assess right ventricular (RV) function and pulmonary regurgitant fraction (PRF) in patients with repaired tetralogy of Fallot (TOF). Thirty-three consecutive patients with repaired TOF underwent retrospective ECG-gated CCT and 3-Tesla CMR. RV and left ventricular (LV) end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV) and ejection fraction (EF) were measured using CCT and CMR. PRF-CCT (%) was defined as (RVSV - LVSV)/RVSV. PRF-CMR (%) was measured by the phase-contrast method. Repeated measurements were performed to determine intra- and interobserver variability. CCT measurements, including PRF, correlated highly with the CMR reference (r = 0.71-0.96). CCT overestimated RVEDV (mean difference, 17.1 ± 2.9 ml), RVESV (12.9 ± 2.1 ml) and RVSV (4.2 ± 2.0 ml), and underestimated RVEF (-2.6 ± 1.0 %) and PRF (-9.1 ± 2.0 %) compared with CMR. The limits of agreement between CCT and CMR were in a good range for all measurements. The variability in CCT measurements was lower than those in CMR. The estimated effective radiation dose was 7.6 ± 2.6 mSv. 256-slice CCT can assess RV function and PRF with relatively low dose radiation exposure in patients with repaired TOF, but overestimates RV volume and underestimates PRF. (orig.)

  1. HR 3 tesla MRI for the diagnosis of endolymphatic hydrops and differential diagnosis of inner ear tumors. Demonstrated by two cases with similar symptoms

    The synchronous appearance of different inner ear pathologies with a nearly equivalent clinical manifestation such as Meniere's disease and vestibular schwannoma is very rare but leads to a relevant dilemma concerning therapy options. MRI is the method of choice to detect intralabyrinthine tumors. Since endolymphatic hydrops is considered the morphological equivalent of Meniere's disease, magnetic resonance imaging including hT2w-FLAIR sequences 4 h after i.v. administration of gadolinium-based contrast agents (GBCA) allows the diagnosis and grading of endolymphatic hydrops in vivo synchronous to diagnosis and monitoring of ILT. To this day, only a few cases of intralabyrinthine schwannoma could be shown to appear simultaneously with endolymphatic hydrops by MRI, but to our knowledge the dedicated distinction of endolymphatic space has not been previously demonstrated. The aim of this work was not only to detect the coincidence of endolymphatic hydrops and vestibular schwannoma, but also to differentiate tumor tissue from endolymphatic space by 3 Tesla MRI. This enables therapy options that are originally indicated for Meniere's disease. The aim of this work was to describe the feasibility and usefulness of endolymphatic hydrops MRI on intralabyrinthal tumors in a special case of intravestibular schwannoma to demonstrate the high clinical relevance and impact in therapeutic decision-making for the synchronous appearance of endolymphatic hydrops and intralabyrinthine tumors. Therefore, we present a typical case of Meniere's disease in contrast to a patient with an intralabyrinthine schwannoma and Meniere's-like symptoms. (orig.)

  2. Quantitative assessment of right ventricular function and pulmonary regurgitation in surgically repaired tetralogy of Fallot using 256-slice CT: comparison with 3-Tesla MRI

    To compare 256-slice cardiac computed tomography (CCT) with cardiac magnetic resonance (CMR) imaging to assess right ventricular (RV) function and pulmonary regurgitant fraction (PRF) in patients with repaired tetralogy of Fallot (TOF). Thirty-three consecutive patients with repaired TOF underwent retrospective ECG-gated CCT and 3-Tesla CMR. RV and left ventricular (LV) end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV) and ejection fraction (EF) were measured using CCT and CMR. PRF-CCT (%) was defined as (RVSV - LVSV)/RVSV. PRF-CMR (%) was measured by the phase-contrast method. Repeated measurements were performed to determine intra- and interobserver variability. CCT measurements, including PRF, correlated highly with the CMR reference (r = 0.71-0.96). CCT overestimated RVEDV (mean difference, 17.1 ± 2.9 ml), RVESV (12.9 ± 2.1 ml) and RVSV (4.2 ± 2.0 ml), and underestimated RVEF (-2.6 ± 1.0 %) and PRF (-9.1 ± 2.0 %) compared with CMR. The limits of agreement between CCT and CMR were in a good range for all measurements. The variability in CCT measurements was lower than those in CMR. The estimated effective radiation dose was 7.6 ± 2.6 mSv. 256-slice CCT can assess RV function and PRF with relatively low dose radiation exposure in patients with repaired TOF, but overestimates RV volume and underestimates PRF. (orig.)

  3. Comparison of Deep Brain Stimulation Lead Targeting Accuracy and Procedure Duration between 1.5-and 3-Tesla Interventional Magnetic Resonance Imaging Systems: An Initial 12-Month Experience

    Southwell, DG; Narvid, JA; Martin, AJ; Qasim, SE; Starr, PA; Larson, PS

    2016-01-01

    Interventional magnetic resonance imaging (iMRI) allows deep brain stimulator lead placement under general anesthesia. While the accuracy of lead targeting has been described for iMRI systems utilizing 1.5-tesla magnets, a similar assessment of 3-tesla iMRI procedures has not been performed.To compare targeting accuracy, the number of lead targeting attempts, and surgical duration between procedures performed on 1.5- and 3-tesla iMRI systems.Radial targeting error, the number of targeting att...

  4. Magnetic resonance imaging evaluation after implantation of a titanium cervical disc prosthesis: a comparison of 1.5 and 3 Tesla magnet strength

    Sundseth, Jarle; Jacobsen, Eva A.; Kolstad, Frode; Nygaard, Oystein P.; Zwart, John A.; Hol, Per K.

    2013-01-01

    Purpose Cervical disc prostheses induce significant amount of artifact in magnetic resonance imaging which may complicate radiologic follow-up after surgery. The purpose of this study was to investigate as to what extent the artifact, induced by the frequently used Discover® cervical disc prosthesis, impedes interpretation of the MR images at operated and adjacent levels in 1.5 and 3 Tesla MR. Methods Ten subsequent patients were investigated in both 1.5 and 3 Tesla MR with standard image seq...

  5. Comparison of Pelvic Phased-Array versus Endorectal Coil Magnetic Resonance Imaging at 3 Tesla for Local Staging of Prostate Cancer

    Kim, Bum Soo; Kim, Tae-Hwan; Kwon, Tae Gyun; Yoo, Eun Sang

    2012-01-01

    Purpose Several studies have demonstrated the superiority of endorectal coil magnetic resonance imaging (MRI) over pelvic phased-array coil MRI at 1.5 Tesla for local staging of prostate cancer. However, few have studied which evaluation is more accurate at 3 Tesla MRI. In this study, we compared the accuracy of local staging of prostate cancer using pelvic phased-array coil or endorectal coil MRI at 3 Tesla. Materials and Methods Between January 2005 and May 2010, 151 patients underwent radi...

  6. High-resolution flurescence spectroscopy in immunoanalysis

    Grubor, Nenad M.

    2005-05-01

    The work presented in this dissertation combines highly sensitive and selective fluorescence line-narrowing spectroscopy (FLNS) detection with various modes of immunoanalytical techniques. It has been shown that FLNS is capable of directly probing molecules immunocomplexed with antibodies, eliminating analytical ambiguities that may arise from interferences that accompany traditional immunochemical techniques. Moreover, the utilization of highly cross-reactive antibodies for highly specific analyte determination has been demonstrated. Finally, they demonstrate the first example of the spectral resolution of diastereomeric analytes based on their interaction with a cross-reactive antibody.

  7. Utility and limitations of 3-Tesla diffusion-weighted magnetic resonance imaging for differentiation of renal tumors

    Sevcenco, S., E-mail: sabina.sevcenco@meduniwien.ac.at [Medical University of Vienna, Dept. of Urology, Waehringer Gürtel 18-20, 1090 Vienna (Austria); Heinz-Peer, G., E-mail: gertraud.heinz-peer@meduniwien.ac.at [Medical University of Vienna, Dept. of Biomedical Imaging and Image-guided Therapy, Waehringer Gürtel 18-20, 1090 Vienna (Austria); Ponhold, L., E-mail: lothar.ponhold@meduniwien.ac.at [Medical University of Vienna, Dept. of Biomedical Imaging and Image-guided Therapy, Waehringer Gürtel 18-20, 1090 Vienna (Austria); Javor, D., E-mail: domagoj.javor@meduniwien.ac.at [Medical University of Vienna, Dept. of Biomedical Imaging and Image-guided Therapy, Waehringer Gürtel 18-20, 1090 Vienna (Austria); Kuehhas, F.E., E-mail: frenklin.kuehhas@meduniwien.ac.at [Medical University of Vienna, Dept. of Urology, Waehringer Gürtel 18-20, 1090 Vienna (Austria); Klingler, H.C., E-mail: christoph.klingler@meduniwien.ac.at [Medical University of Vienna, Dept. of Urology, Waehringer Gürtel 18-20, 1090 Vienna (Austria); Remzi, M., E-mail: mesut.remzi@gmx.at [Medical University of Vienna, Dept. of Urology, Waehringer Gürtel 18-20, 1090 Vienna (Austria); Weibl, P., E-mail: peter.weibl@meduniwien.ac.at [Medical University of Vienna, Dept. of Urology, Waehringer Gürtel 18-20, 1090 Vienna (Austria); Shariat, S.F., E-mail: sfshariat@gmail.com [Medical University of Vienna, Dept. of Urology, Waehringer Gürtel 18-20, 1090 Vienna (Austria); Baltzer, P.A., E-mail: pascal.baltzer@meduniwien.ac.at [Medical University of Vienna, Dept. of Biomedical Imaging and Image-guided Therapy, Waehringer Gürtel 18-20, 1090 Vienna (Austria)

    2014-06-15

    Objective: To investigate utility and limitations of 3-Tesla diffusion-weighted (DW) magnetic resonance imaging (MRI) for differentiation of benign versus malignant renal lesions and renal cell carcinoma (RCC) subtypes. Materials and methods: Sixty patients with 71 renal lesions underwent 3 Tesla DW-MRI of the kidney before diagnostic tissue confirmation. The images were retrospectively evaluated blinded to histology. Single-shot echo-planar imaging was used as the DW imaging technique. Apparent diffusion coefficient (ADC) values were measured and compared with histopathological characteristics. Results: There were 54 malignant and 17 benign lesions, 46 lesions being small renal masses ≤4 cm. Papillary RCC lesions had lower ADC values (p = 0.029) than other RCC subtypes (clear cell or chromophobe). Diagnostic accuracy of DW-MRI for differentiation of papillary from non-papillary RCC was 70.3% resulting in a sensitivity and specificity of 64.3% (95% CI, 35.1–87.2) and 77.1 (95% CI, 59.9–89.6%). Accuracy increased to 83.7% in small renal masses (≤4 cm diameter) and sensitivity and specificity were 75.0% and 88.5%, respectively. The ADC values did not differ significantly between benign and malignant renal lesions (p = 0.45). Conclusions: DW-MRI seems to distinguish between papillary and other subtypes of RCCs especially in small renal masses but could not differentiate between benign and malignant renal lesions. Therefore, the use of DW-MRI for preoperative differentiation of renal lesions is limited.

  8. Utility and limitations of 3-Tesla diffusion-weighted magnetic resonance imaging for differentiation of renal tumors

    Objective: To investigate utility and limitations of 3-Tesla diffusion-weighted (DW) magnetic resonance imaging (MRI) for differentiation of benign versus malignant renal lesions and renal cell carcinoma (RCC) subtypes. Materials and methods: Sixty patients with 71 renal lesions underwent 3 Tesla DW-MRI of the kidney before diagnostic tissue confirmation. The images were retrospectively evaluated blinded to histology. Single-shot echo-planar imaging was used as the DW imaging technique. Apparent diffusion coefficient (ADC) values were measured and compared with histopathological characteristics. Results: There were 54 malignant and 17 benign lesions, 46 lesions being small renal masses ≤4 cm. Papillary RCC lesions had lower ADC values (p = 0.029) than other RCC subtypes (clear cell or chromophobe). Diagnostic accuracy of DW-MRI for differentiation of papillary from non-papillary RCC was 70.3% resulting in a sensitivity and specificity of 64.3% (95% CI, 35.1–87.2) and 77.1 (95% CI, 59.9–89.6%). Accuracy increased to 83.7% in small renal masses (≤4 cm diameter) and sensitivity and specificity were 75.0% and 88.5%, respectively. The ADC values did not differ significantly between benign and malignant renal lesions (p = 0.45). Conclusions: DW-MRI seems to distinguish between papillary and other subtypes of RCCs especially in small renal masses but could not differentiate between benign and malignant renal lesions. Therefore, the use of DW-MRI for preoperative differentiation of renal lesions is limited

  9. Thomson parabola: a high resolution ion spectrometer

    A compact high resolution and high dispersion Thomson parabola ion spectrometer (TPS) comprising of Time-of-Flight diagnostics has been developed for simultaneously resolving protons and low-Z ions of energy from 1 keV/nucleon to 1 MeV/nucleon and incorporated in the Laser plasma experimental chamber. The ion spectrometer was optimized with carbon target. The carbon ions of charge states 1+ to 6+ were measured in the energy range from 3 keV to 300 keV, which were verified by time-of-flight measurements. The energy resolution (E/dE) of TPS was achieved up to 50 depending on the energy and charge states of the ions. The experimental results were in fairly good agreement with the theoretical simulations. (author)

  10. Star formation seen with high resolution spectroscopy.

    Winnewisser, G.

    1990-03-01

    More than 90 anorganic and organic molecules have been detected by high resolution spectroscopy in interstellar molecular clouds or in the envelopes of stars. The detected wavelengths of the lines - predominantly located in the millimeter- and submillimeter wavelength region - unequivocally identify the molecules and give precise knowledge of the physical and chemical conditions of molecular clouds from which the radiation emanates. The line intensities and line profiles contain information about the densities, temperatures and dynamics prevailing in molecular clouds.

  11. High resolution NMR theory and chemical applications

    Becker, Edwin D

    1969-01-01

    High Resolution NMR: Theory and Chemical Applications focuses on the applications of nuclear magnetic resonance (NMR), as well as chemical shifts, lattices, and couplings. The book first offers information on the theory of NMR, including nuclear spin and magnetic moment, spin lattice relaxation, line widths, saturation, quantum mechanical description of NMR, and ringing. The text then ponders on instrumentation and techniques and chemical shifts. Discussions focus on the origin of chemical shifts, reference compounds, empirical correlations of chemical shifts, modulation and phase detection,

  12. Advanced interferometric techniques for high resolution bathymetry

    LLORT PUJOL, Gerard; SINTES, Christophe; Chonavel, Thierry; MORRISON, Archie T.; DANIEL, Sylvie

    2012-01-01

    Current high-resolution side scan and multibeam sonars produce very large data sets. However, conventional interferometry-based bathymetry algorithms underestimate the potential information of such soundings, generally because they use small baselines to avoid phase ambiguity. Moreover, these algorithms limit the triangulation capabilities of multibeam echosounders to the detection of one sample per beam, i.e., the zero-phase instant. In this paper we argue that the correlation between signal...

  13. Petrous apex mucocele: high resolution CT.

    Memis, A; Memis, A; Alper, H; Calli, C; Ozer, H; Ozdamar, N

    1994-11-01

    Mucocele of the petrous apex is very rare, only three cases having been reported. Since this area is inaccessible to direct examination, imaging, preferably high resolution computed tomography (HR CT) is essential. We report a case showing an eroding, non enhancing mass with sharp, lobulated contours, within the petrous apex. The presence of a large air cell on the opposite side suggested a mucocele. PMID:7862284

  14. Petrous apex mucocele: high resolution CT

    Memis, A. [Dept. of Radiology, Hospital of Ege Univ., Bornova, Izmir (Turkey); Memis, A. [Dept. of Radiology, Hospital of Ege Univ., Bornova, Izmir (Turkey); Alper, H. [Dept. of Radiology, Hospital of Ege Univ., Bornova, Izmir (Turkey); Calli, C. [Dept. of Radiology, Hospital of Ege Univ., Bornova, Izmir (Turkey); Ozer, H. [Dept. of Radiology, Hospital of Ege Univ., Bornova, Izmir (Turkey); Ozdamar, N. [Dept. of Neurosurgery, Hospital of Ege Univ., Bornova, Izmir (Turkey)

    1994-11-01

    Mucocele of the petrous apex is very rare, only three cases having been reported. Since this area is inaccessible to direct examination, imaging, preferably high resolution computed tomography (HR CT) is essential. We report a case showing an eroding, non enhancing mass with sharp, lobulated contours, within the petrous apex. The presence of a large air cell on the opposite side suggested a mucocele. (orig.)

  15. Petrous apex mucocele: high resolution CT

    Mucocele of the petrous apex is very rare, only three cases having been reported. Since this area is inaccessible to direct examination, imaging, preferably high resolution computed tomography (HR CT) is essential. We report a case showing an eroding, non enhancing mass with sharp, lobulated contours, within the petrous apex. The presence of a large air cell on the opposite side suggested a mucocele. (orig.)

  16. High Resolution Neutron Imaging of Microfossils

    Jakoubek, J.; Pospíšil, S.; Vacík, Jiří; Vavřík, Daniel

    New York : IEEE, 2012 - (Yu, B.), s. 226-229 ISBN 978-1-4673-2030-6. ISSN 1082-3654. [IEEE Nuclear Science Symposium and Medical Imaging Conference. Anaheim (US), 29.10.2012-3.11.2012] Institutional support: RVO:68378297 ; RVO:61389005 Keywords : Carbon structures * Detectability * High resolution Subject RIV: BM - Solid Matter Physics ; Magnetism; JL - Materials Fatigue, Friction Mechanics (UTAM-F)

  17. NPS high resolution synthetic aperture sonar

    Welter, Joseph Donald

    1995-01-01

    This thesis investigated the use of synthetic aperture techniques to achieve a long effective aperture, high resolution, imaging sonar. The approach included a full simulation of the system using the MATLAB programming environment that provided a model for developing six data processing algorithms and a working 25KHz, 1 m baseline, air medium synthetic aperture sonar. The six azimuthal processing techniques included: (1) a normal, real aperture, (2) an unfocussed synthetic aperture, (3) a hyb...

  18. High resolution powder diffraction at ISIS

    This paper reviews the initial commissioning of the high resolution time-of-flight neutron powder diffractometer, HRPD, on the Spallation Neutron Source, ISIS, at the Rutherford Appleton Laboratory. Preliminary results have confirmed both intensity and resolution predictions indicating that (δd/d) lies between 0.04 % and 0.08 % for all d-spacings between 0.02 and 5 A. The scientific potential of this increased resolution over existing time-of-flight diffractometers has been demonstrated in the successful ab initio structure determination of an unknown inorganic material, FeAsO4, and the detailed study of subtle symmetry changes in NiO. The true instrumental resolution, however, has been observed in only a small number of experiments: sample broadening is often seen to play a dominant role in the determination of the peak shape, particularly at longer d-spacings. This leads to additional useful information about macroscopic properties, such as an anisotropic crystallite size, strain distribution and sample homogeneity, but also results in a significant increase in complexity of peak-shape description and data-analysis strategy. (author) 13 refs., 8 figs., 4 tabs

  19. High-Resolution MRI in Rectal Cancer

    High-resolution MRI is the best method of assessing the relation of the rectal tumor with the potential circumferential resection margin (CRM). Therefore it is currently considered the method of choice for local staging of rectal cancer. The primary surgery of rectal cancer is total mesorectal excision (TME), which plane of dissection is formed by the mesorectal fascia surrounding mesorectal fat and rectum. This fascia will determine the circumferential margin of resection. At the same time, high resolution MRI allows adequate pre-operative identification of important prognostic risk factors, improving the selection and indication of therapy for each patient. This information includes, besides the circumferential margin of resection, tumor and lymph node staging, extramural vascular invasion and the description of lower rectal tumors. All these should be described in detail in the report, being part of the discussion in the multidisciplinary team, the place where the decisions involving the patient with rectal cancer will take place. The aim of this study is to provide the information necessary to understand the use of high resolution MRI in the identification of prognostic risk factors in rectal cancer. The technical requirements and standardized report for this study will be describe, as well as the anatomical landmarks of importance for the total mesorectal excision (TME), as we have said is the surgery of choice for rectal cancer. (authors)

  20. High Speed and High Resolution Table-Top Nanoscale Imaging

    Tadesse, G K; Demmler, S; HÄdrich, S; Wahyutama, I; Steinert, M; Spielmann, C; ZÜrch, M; TÜnnermann, A; Limpert, J; Rothhardt, J

    2016-01-01

    We present a table-top coherent diffraction imaging (CDI) experiment based on high-order harmonics generated at 18 nm by a high average power femtosecond fiber laser system. The high photon flux, narrow spectral bandwidth and high degree of spatial coherence allow for ultra-high sub-wavelength resolution imaging at a high numerical aperture. Our experiments demonstrate a half-pitch resolution of 13.6 nm, very close to the actual Abbe-limit of 12.4 nm, which is the highest resolution achieved from any table-top XUV or X-ray microscope. In addition, 20.5 nm resolution was achieved with only 3 sec of integration time bringing live diffraction imaging and 3D tomography on the nanoscale one step closer to reality. The current resolution is solely limited by the wavelength and the detector size. Thus, table-top nanoscopes with only a few-nm resolutions are in reach and will find applications in many areas of science and technology.

  1. SPIRAL2/DESIR high resolution mass separator

    DESIR is the low-energy part of the SPIRAL2 ISOL facility under construction at GANIL. DESIR includes a high-resolution mass separator (HRS) with a designed resolving power m/Δm of 31,000 for a 1 π-mm-mrad beam emittance, obtained using a high-intensity beam cooling device. The proposed design consists of two 90-degree magnetic dipoles, complemented by electrostatic quadrupoles, sextupoles, and a multipole, arranged in a symmetric configuration to minimize aberrations. A detailed description of the design and results of extensive simulations are given

  2. High-angular Resolution Laser Threat Warner

    Sushil Kumar

    2007-07-01

    Full Text Available In this paper, the design and development aspects of a high-angular resolution laser-threat Warner developed at the Laser Science & Technology Centre (LASTEC, Delhi are presented. It describes a high-angular resolution laser-threat warner capable of giving warning with a resolution of i 3" when it is exposed to laser radiation from visible and near-IR pulsed solid-state laser source. It has a field of view of 90' in the azimuth direction, whereas the elevation coverage is between -5" and + 25". It is capable of handling multiple types of laser threats covering wavelength from 400 nm to 1100 nm and has an operational range of 4 km for a Q-switched laser source energy (10 ns of 10 mJ/pulse and output beam divergence of 1 mrad. The paper also describes its simulated evaluation process and field-testing which it has undergone. The result of field-testing confirms that it meets all its performance specifications mentioned above.

  3. Radiation length imaging with high resolution telescopes

    Stolzenberg, U; Schwenker, B; Wieduwilt, P; Marinas, C; Lütticke, F

    2016-01-01

    The construction of low mass vertex detectors with a high level of system integration is of great interest for next generation collider experiments. Radiation length images with a sufficient spatial resolution can be used to measure and disentangle complex radiation length $X$/$X_0$ profiles and contribute to the understanding of vertex detector systems. Test beam experiments with multi GeV particle beams and high-resolution tracking telescopes provide an opportunity to obtain precise 2D images of the radiation length of thin planar objects. At the heart of the $X$/$X_0$ imaging is a spatially resolved measurement of the scattering angles of particles traversing the object under study. The main challenges are the alignment of the reference telescope and the calibration of its angular resolution. In order to demonstrate the capabilities of $X$/$X_0$ imaging, a test beam experiment has been conducted. The devices under test were two mechanical prototype modules of the Belle II vertex detector. A data sample of ...

  4. High resolution coherent control measurements on KRb

    We present high resolution optimal control on KRb in a molecular beam. Isotopomer selective ionization is performed by closed loop experiments with a pulse shaper consisting of two liquid crystal masks with 640 pixels each. This yields a spectral resolution of 1.84 cm-1/pixel which is according to our knowledge the highest that have been used for coherent control measurements until now. The isotopomer ratio 124KRb/126KRb is optimized by pure and combined phase and amplitude modulation and the optimized pulse shapes indicate which isotopic composition of the heavier isotopomer mass 126KRb mainly contributes to our measurements. Moreover, the involved vibronic transitions are exposed in the optimized spectra

  5. Processing method for high resolution monochromator

    A processing method for high resolution monochromator (HRM) has been developed at Japanese Atomic Energy Agency/Quantum Beam Science Directorate/Synchrotron Radiation Research unit at SPring-8. For manufacturing a HRM, a sophisticated slicing machine and X-ray diffractometer have been installed for shaping a crystal ingot and orienting precisely the surface of a crystal ingot, respectively. The specification of the slicing machine is following; Maximum size of a diamond blade is φ 350mm in diameter, φ 38.1mm in the spindle diameter, and 2mm in thickness. A large crystal such as an ingot with 100mm in diameter, 200mm in length can be cut. Thin crystal samples such as a wafer can be also cut using by another sample holder. Working distance of a main shaft with the direction perpendicular to working table in the machine is 350mm at maximum. Smallest resolution of the main shaft with directions of front-and-back and top-and-bottom are 0.001mm read by a digital encoder. 2mm/min can set for cutting samples in the forward direction. For orienting crystal faces relative to the blade direction adjustment, a one-circle goniometer and 2-circle segment are equipped on the working table in the machine. A rotation and a tilt of the stage can be done by manual operation. Digital encoder in a turn stage is furnished and has angle resolution of less than 0.01 degrees. In addition, a hand drill as a supporting device for detailed processing of crystal is prepared. Then, an ideal crystal face can be cut from crystal samples within an accuracy of about 0.01 degrees. By installation of these devices, a high energy resolution monochromator crystal for inelastic x-ray scattering and a beam collimator are got in hand and are expected to be used for nanotechnology studies. (author)

  6. High-resolution simulation of field emission

    High-resolution simulations of field-emission electron sources have been made using the electron-optics program EGN2. Electron emission distributions are made using the Fowler-Nordheim equation. Mesh resolution in the range of 1-5 A is required to adequately model surface details that can result in emission currents in the range found experimentally. A typical problem stars with mechanical details with dimensions of about 1 μm. To achieve high resolution a new boundary is defined by the tip, a nearby equipotential line, and a pair of field lines. The field lines (one of which is normally the axis of symmetry) define Neumann boundaries. This new boundary is then used by the boundary preprocessor POLYGON to create an enlarged version of the problem, typically by a factor of 10. This process can be repeated until adequate resolution is obtained to simulate surface details, such as a microprotusion, that could sufficiently enhance the surface electric fields and cause field emission. When simulating experimental conditions under which emission of several microamperes per tip were observed, it was found that both a locally reduced work function and a surface protrusion were needed to duplicate the experimentel results. If only a local region of reduced work function is used, the area involved and the extent of the reduction both need to be very large to reproduce the observed emission. If only a surface protrusion is used, it is possible to get the observed emission current with a reasonable protrusion of length a few times radius, but then the resulting beam spreads over a very large solid angle due to the strong local radial electric fields. (orig.)

  7. In vivo functional connectome of human brainstem nuclei of the ascending arousal, autonomic and motor systems by high spatial resolution 7 Tesla fMRI

    Bianciardi, Marta; Toschi, Nicola; Eichner, Cornelius; Polimeni, Jonathan R.; Setsompop, Kawin; Brown, Emery N.; Hamalainen, Matti S.; Rosen, Bruce R.; Wald, Lawrence L.

    2016-01-01

    Object To map the in vivo human functional connectivity of several brainstem nuclei with the rest of the brain by using seed-based correlation of ultra-high magnetic field functional magnetic resonance imaging (fMRI) data. Materials and Methods We used the recently developed template of 11 brainstem nuclei derived from multi-contrast structural MRI at 7 Tesla as seed regions to determine their connectivity to the rest of the brain. To achieve this, we utilized the increased contrast-to-noise ratio of 7 Tesla fMRI compared to 3 Tesla and the time efficient simultaneous multi-slice imaging to cover the brain with high spatial resolution (1.1 mm-isotropic nominal resolution) while maintaining a short repetition time (2.5 s). Results The delineated Pearson’s correlation-based functional connectivity diagrams (connectomes) of 11 brainstem nuclei of the ascending arousal, motor and autonomic systems from 12 controls are presented and discussed in the context of existing histology and animal work. Conclusion Considering that the investigated brainstem nuclei play a crucial role in several vital functions, the delineated preliminary connectomes might prove useful for future in vivo research and clinical studies of human brainstem function and pathology, including disorders of consciousness, sleep disorders, autonomic disorders, Parkinson’s disease and other motor disorders. PMID:27126248

  8. High resolution hyperspectral imaging with a high throughput virtual slit

    Gooding, Edward A.; Gunn, Thomas; Cenko, Andrew T.; Hajian, Arsen R.

    2016-05-01

    Hyperspectral imaging (HSI) device users often require both high spectral resolution, on the order of 1 nm, and high light-gathering power. A wide entrance slit assures reasonable étendue but degrades spectral resolution. Spectrometers built using High Throughput Virtual Slit™ (HTVS) technology optimize both parameters simultaneously. Two remote sensing use cases that require high spectral resolution are discussed. First, detection of atmospheric gases with intrinsically narrow absorption lines, such as hydrocarbon vapors or combustion exhaust gases such as NOx and CO2. Detecting exhaust gas species with high precision has become increasingly important in the light of recent events in the automobile industry. Second, distinguishing reflected daylight from emission spectra in the visible and NIR (VNIR) regions is most easily accomplished using the Fraunhofer absorption lines in solar spectra. While ground reflectance spectral features in the VNIR are generally quite broad, the Fraunhofer lines are narrow and provide a signature of intrinsic vs. extrinsic illumination. The High Throughput Virtual Slit enables higher spectral resolution than is achievable with conventional spectrometers by manipulating the beam profile in pupil space. By reshaping the instrument pupil with reflective optics, HTVS-equipped instruments create a tall, narrow image profile at the exit focal plane, typically delivering 5X or better the spectral resolution achievable with a conventional design.

  9. High Spectral Resolution Lidar: System Calibration

    Vivek Vivekanandan, J.; Morley, Bruce; Spuler, Scott; Eloranta, Edwin

    2015-04-01

    One of the unique features of the high spectral resolution lidar (HSRL) is simultaneous measurements of backscatter and extinction of atmosphere. It separates molecular scattering from aerosol and cloud particle backscatter based on their Doppler spectrum width. Scattering from aerosol and cloud particle are referred as Mie scattering. Molecular or Rayleigh scattering is used as a reference for estimating aerosol extinction and backscatter cross-section. Absolute accuracy of the backscattered signals and their separation into Rayleigh and Mie scattering depends on spectral purity of the transmitted signals, accurate measurement of transmit power, and precise performance of filters. Internal calibration is used to characterize optical subsystems Descriptions of high spectral resolution lidar system and its measurement technique can be found in Eloronta (2005) and Hair et al.(2001). Four photon counting detectors are used to measure the backscatter from the combined Rayleigh and molecular scattering (high and low gain), molecular scattering and cross-polarized signal. All of the detectors are sensitive to crosstalk or leakage through the optical filters used to separate the received signals and special data files are used to remove these effects as much as possible. Received signals are normalized with respect to the combined channel response to Mie and Rayleigh scattering. The laser transmit frequency is continually monitored and tuned to the 1109 Iodine absorption line. Aerosol backscatter cross-section is measured by referencing the aerosol return signal to the molecular return signal. Extinction measurements are calculated based on the differences between the expected (theoretical) and actual change in the molecular return. In this paper an overview of calibration of the HSRL is presented. References: Eloranta, E. W., High Spectral Resolution Lidar in Lidar: Range-Resolved Optical Remote Sensing of the Atmosphere, Klaus Weitkamp editor, Springer Series in Optical

  10. Diffusion-weighted imaging of breast tumours at 3 Tesla and 7 Tesla: a comparison

    To compare bilateral diffusion-weighted MR imaging (DWI) at 3 T and 7 T in the same breast tumour patients. Twenty-eight patients were included in this IRB-approved study (mean age 56 ± 16 years). Before contrast-enhanced imaging, bilateral DWI with b = 0 and 850 s/mm2 was performed in 2:56 min (3 T) and 3:48 min (7 T), using readout-segmented echo planar imaging (rs-EPI) with a 1.4 x 1.4 mm2 (3 T)/0.9 x 0.9 mm2 (7 T) in-plane resolution. Apparent diffusion coefficients (ADC), signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were assessed. Twenty-eight lesions were detected (18 malignant, 10 benign). CNR and SNR were comparable at both field strengths (p > 0.3). Mean ADC values at 7 T were 4-22 % lower than at 3 T (p ≤ 0.03). An ADC threshold of 1.275 x 10-3 mm2/s resulted in a diagnostic specificity of 90 % at both field strengths. The sensitivity was 94 % and 100 % at 3 T and 7 T, respectively. 7-T DWI of the breast can be performed with 2.4-fold higher spatial resolution than 3 T, without significant differences in SNR if compared to 3 T. (orig.)

  11. Diffusion-weighted imaging of breast tumours at 3 Tesla and 7 Tesla: a comparison

    Gruber, S.; Minarikova, L.; Zaric, O.; Chmelik, M.; Strasser, B.; Trattnig, S.; Bogner, W. [Medical University Vienna, MRCE, Department of Biomedical imaging and Image-Guided Therapy, Vienna (Austria); Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna (Austria); Pinker, K.; Baltzer, P.; Helbich, T. [Medical University Vienna, Division of Molecular and Gender Imaging, Department of Biomedical imaging and Image-Guided Therapy, Vienna (Austria)

    2016-05-15

    To compare bilateral diffusion-weighted MR imaging (DWI) at 3 T and 7 T in the same breast tumour patients. Twenty-eight patients were included in this IRB-approved study (mean age 56 ± 16 years). Before contrast-enhanced imaging, bilateral DWI with b = 0 and 850 s/mm{sup 2} was performed in 2:56 min (3 T) and 3:48 min (7 T), using readout-segmented echo planar imaging (rs-EPI) with a 1.4 x 1.4 mm{sup 2} (3 T)/0.9 x 0.9 mm{sup 2} (7 T) in-plane resolution. Apparent diffusion coefficients (ADC), signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were assessed. Twenty-eight lesions were detected (18 malignant, 10 benign). CNR and SNR were comparable at both field strengths (p > 0.3). Mean ADC values at 7 T were 4-22 % lower than at 3 T (p ≤ 0.03). An ADC threshold of 1.275 x 10{sup -3} mm{sup 2}/s resulted in a diagnostic specificity of 90 % at both field strengths. The sensitivity was 94 % and 100 % at 3 T and 7 T, respectively. 7-T DWI of the breast can be performed with 2.4-fold higher spatial resolution than 3 T, without significant differences in SNR if compared to 3 T. (orig.)

  12. Development of a high resolution and high dispersion Thomson parabola

    Here, we report on the development of a novel high resolution and high dispersion Thomson parabola for simultaneously resolving protons and low-Z ions of more than 100 MeV/nucleon necessary to explore novel laser ion acceleration schemes. High electric and magnetic fields enable energy resolutions of ΔE/E < 5% at 100 MeV/nucleon and impede premature merging of different ion species at low energies on the detector plane. First results from laser driven ion acceleration experiments performed at the Trident Laser Facility demonstrate high resolution and superior species and charge state separation of this novel Thomson parabola for ion energies of more than 30 MeV/nucleon.

  13. High-resolution X-ray television and high-resolution video recorders

    The improved transmission properties of the high-resolution X-ray television chain described here make it possible to transmit more information per television image. The resolution in the fluoroscopic image, which is visually determined, depends on the dose rate and the inertia of the television pick-up tube. This connection is discussed. In the last few years, video recorders have been increasingly used in X-ray diagnostics. The video recorder is a further quality-limiting element in X-ray television. The development of function patterns of high-resolution magnetic video recorders shows that this quality drop may be largely overcome. The influence of electrical band width and number of lines on the resolution in the X-ray television image stored is explained in more detail. (orig.)

  14. High-resolution phylogenetic microbial community profiling

    Singer, Esther; Coleman-Derr, Devin; Bowman, Brett; Schwientek, Patrick; Clum, Alicia; Copeland, Alex; Ciobanu, Doina; Cheng, Jan-Fang; Gies, Esther; Hallam, Steve; Tringe, Susannah; Woyke, Tanja

    2014-03-17

    The representation of bacterial and archaeal genome sequences is strongly biased towards cultivated organisms, which belong to merely four phylogenetic groups. Functional information and inter-phylum level relationships are still largely underexplored for candidate phyla, which are often referred to as microbial dark matter. Furthermore, a large portion of the 16S rRNA gene records in the GenBank database are labeled as environmental samples and unclassified, which is in part due to low read accuracy, potential chimeric sequences produced during PCR amplifications and the low resolution of short amplicons. In order to improve the phylogenetic classification of novel species and advance our knowledge of the ecosystem function of uncultivated microorganisms, high-throughput full length 16S rRNA gene sequencing methodologies with reduced biases are needed. We evaluated the performance of PacBio single-molecule real-time (SMRT) sequencing in high-resolution phylogenetic microbial community profiling. For this purpose, we compared PacBio and Illumina metagenomic shotgun and 16S rRNA gene sequencing of a mock community as well as of an environmental sample from Sakinaw Lake, British Columbia. Sakinaw Lake is known to contain a large age of microbial species from candidate phyla. Sequencing results show that community structure based on PacBio shotgun and 16S rRNA gene sequences is highly similar in both the mock and the environmental communities. Resolution power and community representation accuracy from SMRT sequencing data appeared to be independent of GC content of microbial genomes and was higher when compared to Illumina-based metagenome shotgun and 16S rRNA gene (iTag) sequences, e.g. full-length sequencing resolved all 23 OTUs in the mock community, while iTags did not resolve closely related species. SMRT sequencing hence offers various potential benefits when characterizing uncharted microbial communities.

  15. Fast Backprojection Techniques for High Resolution Tomography

    Koshev, Nikolay; Miqueles, Eduardo X

    2016-01-01

    Fast image reconstruction techniques are becoming important with the increasing number of scientific cases in high resolution micro and nano tomography. The processing of the large scale three-dimensional data demands new mathematical tools for the tomographic reconstruction task because of the big computational complexity of most current algorithms as the sizes of tomographic data grow with the development of more powerful acquisition hardware and more refined scientific needs. In the present paper we propose a new fast back-projection operator for the processing of tomographic data and compare it against other fast reconstruction techniques.

  16. High resolution extremity CT for biomechanics modeling

    With the advent of ever more powerful computing and finite element analysis (FEA) capabilities, the bone and joint geometry detail available from either commercial surface definitions or from medical CT scans is inadequate. For dynamic FEA modeling of joints, precise articular contours are necessary to get appropriate contact definition. In this project, a fresh cadaver extremity was suspended in parafin in a lucite cylinder and then scanned with an industrial CT system to generate a high resolution data set for use in biomechanics modeling

  17. High resolution CT in lung proteinosis

    Pulmonary alveolar proteinosis is a rare condition and it's etiology remains unknown. It is characterized by the accumulation of a proteinaceous material within alveolar spaces resulting in restrictive lung function, hypoxaemia and a variety of radiological features. We studied high-resolution computed tomography patterns of six patients with primary pulmonary alveolar proteinosis. The most frequently tomographic aspects observed were ground glass opacities in a geographical distribution associated to smooth interlobular septa thickening resulting in a crazy paving pattern. These patterns were found in all the patients and did not have a specific zonal distribution. (author)

  18. Laboratory of High resolution gamma spectrometry

    The Department of Nuclear Experimentation of the Nuclear Systems Management requests the collaboration of the Engineering unit for the supervision of the execution of the work of the High resolution Gamma spectrometry and low bottom laboratory, using the hut of the sub critic reactor of the Nuclear Center of Mexico. This laboratory has the purpose of determining the activity of special materials irradiated in nuclear power plants. In this report the architecture development, concepts, materials and diagrams for the realization of this type of work are presented. (Author)

  19. High resolution magnetic spectrograph 'Grand Raiden'

    In the report of the last 1988, the basic design of a new high resolution (p/Δp = 37750) magnetic spectrograph of the type QSQDMD (+D), named 'Grand Raiden', was presented. Here, we show results of more detailed ray-tracing calculations; the focal line property, the image aberration, and the compensation of the kinematic broadening by multipole fields. The final design of the new DSR (dipole for spin rotation) for the measurement of in-plane spin observables are also reported. (author)

  20. High Resolution Acoustoelastic Measurements of Materials

    McKenna, Mark; Guy, Samuel; Heyman, Joseph

    2006-11-01

    As materials become more complex, there is an increasing need for high resolution measurements to characterize strength and damage in the materials. Typically, the criterion for rejecting a part is based on the detection of a flaw of a specific size in a critical location. Interestingly, if a low stress field exists at the flaw site, the flaw may not grow over time. Similarly, in a part that shows no unacceptable indications, a high stress state may cause the flaw to quickly grow through the part leading to failure. In other cases, a controlled amount of stress (in a specific direction or type) is purposely added to the material to prevent flaw growth. Inspection time intervals are based knowing and controlling the stress environment to predict the flaw growth. Luna Innovations Incorporated has developed a high resolution ultrasonic instrument that can enhance the integrity of critical hardware by measuring changes in the stress state in a material. Knowledge of the stress state plus knowledge of crack sizes greatly improves structural engineers' capability of life prediction. System data will be shown for tests to stresses near holes in laboratory fabricated aircraft metal samples. Scans of the spatial distribution of stresses will be compared with finite element models of the structure.

  1. Crusta: Visualizing High-resolution Global Data

    Bernardin, T. S.; Kreylos, O.; Bowles, C. J.; Cowgill, E.; Hamann, B.; Kellogg, L. H.

    2009-12-01

    Virtual globes have become indispensable tools for visualizing, understanding and presenting data from Earth and other planetary bodies. The scientific community has invested much effort into exploiting existing globes to their fullest potential by refining and adapting their capabilities to better satisfy specific needs. For example, Google Earth provides users with the ability to view hillshade images derived from airborne LiDAR data such as the 2007 Northern California GeoEarthScope data. However, because most available globes were not designed with the specific needs of geoscientists in mind, shortcomings are becoming increasingly evident in geoscience applications such as terrain visualization. In particular, earth scientists struggle to visualize digital elevation models with both high spatial resolution (0.5 - 1 square meters per sample) and large extent (>2000 square kilometers), such as those obtained with airborne LiDAR. To address the specific earth science need of real-time terrain visualization of LiDAR data, we are developing Crusta as part of a close collaboration involving earth and computer scientists. Crusta is a new virtual globe that differs from widely used globes by both providing accurate global data representation and the ability to easily visualize custom topographic and image data. As a result, Crusta enables real-time, interactive visualization of high resolution digital elevation data spanning thousands of square kilometers, such as the complete 2007 Northern California GeoEarthScope airborne LiDAR data set. To implement an accurate data representation and avoid distortion of the display at the poles, where other projections have singularities, Crusta represents the globe as a thirty-sided polyhedron. Each side of this polyhedron can be subdivided to an arbitrarily fine grid on the surface of the globe, which allows Crusta to accommodate input data of arbitrary resolution ranging from global (e.g., Blue Marble) to local (e.g., a tripod

  2. Efficient Compression of High Resolution Climate Data

    Yin, J.; Schuchardt, K. L.

    2011-12-01

    resolution climate data can be massive. Those data can consume a huge amount of disk space for storage, incur significant overhead for outputting data during simulation, introduce high latency for visualization and analysis, and may even make interactive visualization and analysis impossible given the limit of the data that a conventional cluster can handle. These problems can be alleviated by with effective and efficient data compression techniques. Even though HDF5 format supports compression, previous work has mainly focused on employ traditional general purpose compression schemes such as dictionary coder and block sorting based compression scheme. Those compression schemes mainly focus on encoding repeated byte sequences efficiently and are not well suitable for compressing climate data consist mainly of distinguished float point numbers. We plan to select and customize our compression schemes according to the characteristics of high-resolution climate data. One observation on high resolution climate data is that as the resolution become higher, values of various climate variables such as temperature and pressure, become closer in nearby cells. This provides excellent opportunities for predication-based compression schemes. We have performed a preliminary estimation of compression ratios of a very simple minded predication-based compression ratio in which we compute the difference between current float point number with previous float point number and then encoding the exponent and significance part of the float point number with entropy-based compression scheme. Our results show that we can achieve higher compression ratios between 2 and 3 in lossless compression, which is significantly higher than traditional compression algorithms. We have also developed lossy compression with our techniques. We can achive orders of magnitude data reduction while ensure error bounds. Moreover, our compression scheme is much more efficient and introduces much less overhead

  3. High Resolution Camera for Mapping Titan Surface

    Reinhardt, Bianca

    2011-01-01

    Titan, Saturn's largest moon, has a dense atmosphere and is the only object besides Earth to have stable liquids at its surface. The Cassini/Huygens mission has revealed the extraordinary breadth of geological processes shaping its surface. Further study requires high resolution imaging of the surface, which is restrained by light absorption by methane and scattering from aerosols. The Visual and Infrared Mapping Spectrometer (VIMS) onboard the Cassini spacecraft has demonstrated that Titan's surface can be observed within several windows in the near infrared, allowing us to process several regions in order to create a geological map and to determine the morphology. Specular reflections monitored on the lakes of the North Pole show little scattering at 5 microns, which, combined with the present study of Titan's northern pole area, refutes the paradigm that only radar can achieve high resolution mapping of the surface. The present data allowed us to monitor the evolution of lakes, to identify additional lakes at the Northern Pole, to examine Titan's hypothesis of non-synchronous rotation and to analyze the albedo of the North Pole surface. Future missions to Titan could carry a camera with 5 micron detectors and a carbon fiber radiator for weight reduction.

  4. High resolution studies of barium Rydberg states

    The subtle structure of Rydberg states of barium with orbital angular momentum 0, 1, 2 and 3 is investigated. Some aspects of atomic theory for a configuration with two valence electrons are reviewed. The Multi Channel Quantum Defect Theory (MQDT) is concisely introduced as a convenient way to describe interactions between Rydberg series. Three high-resolution UV studies are presented. The first two, presenting results on a transition in indium and europium serve as an illustration of the frequency doubling technique. The third study is of hyperfine structure and isotope shifts in low-lying p states in Sr and Ba. An extensive study of the 6snp and 6snf Rydberg states of barium is presented with particular emphasis on the 6snf states. It is shown that the level structure cannot be fully explained with the model introduced earlier. Rather an effective two-body spin-orbit interaction has to be introduced to account for the observed splittings, illustrating that high resolution studies on Rydberg states offer an unique opportunity to determine the importance of such effects. Finally, the 6sns and 6snd series are considered. The hyperfine induced isotope shift in the simple excitation spectra to 6sns 1S0 is discussed and attention is paid to series perturbers. It is shown that level mixing parameters can easily be extracted from the experimental data. (Auth.)

  5. Principles of high resolution NMR in solids

    Mehring, Michael

    1983-01-01

    The field of Nuclear Magnetic Resonance (NMR) has developed at a fascinating pace during the last decade. It always has been an extremely valuable tool to the organic chemist by supplying molecular "finger print" spectra at the atomic level. Unfortunately the high resolution achievable in liquid solutions could not be obtained in solids and physicists and physical chemists had to live with unresolved lines open to a wealth of curve fitting procedures and a vast amount of speculations. High resolution NMR in solids seemed to be a paradoxon. Broad structure­ less lines are usually encountered when dealing with NMR in solids. Only with the recent advent of mUltiple pulse, magic angle, cross-polarization, two-dimen­ sional and multiple-quantum spectroscopy and other techniques during the last decade it became possible to resolve finer details of nuclear spin interactions in solids. I have felt that graduate students, researchers and others beginning to get involved with these techniques needed a book which trea...

  6. Limiting liability via high resolution image processing

    Greenwade, L.E.; Overlin, T.K.

    1996-12-31

    The utilization of high resolution image processing allows forensic analysts and visualization scientists to assist detectives by enhancing field photographs, and by providing the tools and training to increase the quality and usability of field photos. Through the use of digitized photographs and computerized enhancement software, field evidence can be obtained and processed as `evidence ready`, even in poor lighting and shadowed conditions or darkened rooms. These images, which are most often unusable when taken with standard camera equipment, can be shot in the worst of photographic condition and be processed as usable evidence. Visualization scientists have taken the use of digital photographic image processing and moved the process of crime scene photos into the technology age. The use of high resolution technology will assist law enforcement in making better use of crime scene photography and positive identification of prints. Valuable court room and investigation time can be saved and better served by this accurate, performance based process. Inconclusive evidence does not lead to convictions. Enhancement of the photographic capability helps solve one major problem with crime scene photos, that if taken with standard equipment and without the benefit of enhancement software would be inconclusive, thus allowing guilty parties to be set free due to lack of evidence.

  7. High-Resolution Scintimammography: A Pilot Study

    Rachel F. Brem; Joelle M. Schoonjans; Douglas A. Kieper; Stan Majewski; Steven Goodman; Cahid Civelek

    2002-07-01

    This study evaluated a novel high-resolution breast-specific gamma camera (HRBGC) for the detection of suggestive breast lesions. Methods: Fifty patients (with 58 breast lesions) for whom a scintimammogram was clinically indicated were prospectively evaluated with a general-purpose gamma camera and a novel HRBGC prototype. The results of conventional and high-resolution nuclear studies were prospectively classified as negative (normal or benign) or positive (suggestive or malignant) by 2 radiologists who were unaware of the mammographic and histologic results. All of the included lesions were confirmed by pathology. Results: There were 30 benign and 28 malignant lesions. The sensitivity for detection of breast cancer was 64.3% (18/28) with the conventional camera and 78.6% (22/28) with the HRBGC. The specificity with both systems was 93.3% (28/30). For the 18 nonpalpable lesions, sensitivity was 55.5% (10/18) and 72.2% (13/18) with the general-purpose camera and the HRBGC, respectively. For lesions 1 cm, 7 of 15 were detected with the general-purpose camera and 10 of 15 with the HRBGC. Four lesions (median size, 8.5 mm) were detected only with the HRBGC and were missed by the conventional camera. Conclusion: Evaluation of indeterminate breast lesions with an HRBGC results in improved sensitivity for the detection of cancer, with greater improvement shown for nonpalpable and 1-cm lesions.

  8. High Resolution Spectroscopy of Rocket Triggered Lightning

    Walker, T. D.; Christian, H. J.

    2012-12-01

    In the Summer of 2012, optical spectra of rocket triggered lightning return strokes were recorded at the International Center for Lightning Research and Testing in north-central Florida. The spectra were recorded with a Phantom v710 high speed CMOS camera running at 670 kfps (kiloframes per second) with a 1 microsecond exposure time and a Princeton ProEM high speed CCD camera running at over 1,000 kfps with a 0.5 microsecond exposure time. Three separate volume phase holographic grisms were used during the study and were sensitive in the spectral ranges of 3800-6200 Angstroms, 6400-6700 Angstroms, 7600-7900 Angstroms. The first had a spectral resolution of 5 Angstroms, allowing the separation of singly ionized nitrogen multiplets. These spectra were recorded 50m above the ground with 0.65 m vertical field of view. The second and third spectrometers were recorded with the Princeton ProEM camera and had a resolution of 0.5 Angstroms. These spectra were recorded 50m above ground with 0.06 m vertical field of view. The evolution of important lines in the spectral ranges such as singly ionized nitrogen lines (including spatially resolved 4630 Angstrom multiplet), H-alpha, and a resolved 7774 Angstrom Neutral oxygen triplet will all be presented. The opacity of the lightning channel as well as number density, temperature, and conductivity, will be discussed along with channel base current.

  9. Combined 3 Tesla MRI Biomarkers Improve the Differentiation between Benign vs Malignant Single Ring Enhancing Brain Masses

    Salice, Simone; Esposito, Roberto; Ciavardelli, Domenico; delli Pizzi, Stefano; di Bastiano, Rossella; Tartaro, Armando

    2016-01-01

    Purpose To evaluate whether the combination of imaging biomarkers obtained by means of different 3 Tesla (3T) Magnetic Resonance Imaging (MRI) advanced techniques can improve the diagnostic accuracy in the differentiation between benign and malignant single ring-enhancing brain masses. Materials and Methods 14 patients presenting at conventional 3T MRI single brain mass with similar appearance as regard ring enhancement, presence of peri-lesional edema and absence of hemorrhage signs were included in the study. All lesions were histologically proven: 5 pyogenic abscesses, 6 glioblastomas, and 3 metastases. MRI was performed at 3 Tesla and included Diffusion Weighted Imaging (DWI), Dynamic Susceptibility Contrast -Perfusion Weighted Imaging (DSC-PWI), Magnetic Resonance Spectroscopy (MRS), and Diffusion Tensor Imaging (DTI). Imaging biomarkers derived by those advanced techniques [Cerebral Blood Flow (CBF), relative Cerebral Blood Volume (rCBV), relative Main Transit Time (rMTT), Choline (Cho), Creatine (Cr), Succinate, N-Acetyl Aspartate (NAA), Lactate (Lac), Lipids, relative Apparent Diffusion Coefficient (rADC), and Fractional Anisotropy (FA)] were detected by two experienced neuroradiologists in joint session in 4 areas: Internal Cavity (IC), Ring Enhancement (RE), Peri-Lesional edema (PL), and Contralateral Normal Appearing White Matter (CNAWM). Significant differences between benign (n = 5) and malignant (n = 9) ring enhancing lesions were tested with Mann-Withney U test. The diagnostic accuracy of MRI biomarkers taken alone and MRI biomarkers ratios were tested with Receiver Operating Characteristic (ROC) analysis with an Area Under the Curve (AUC) ≥ 0.9 indicating a very good diagnostic accuracy of the variable. Results Five MRI biomarker ratios achieved excellent accuracy: IC-rADC/PL-NAA (AUC = 1), IC-rADC/IC-FA (AUC = 0.978), RE-rCBV/RE-FA (AUC = 0.933), IC-rADC/RE-FA (AUC = 0.911), and IC-rADC/PL-FA (AUC = 0.911). Only IC-rADC achieved a very good

  10. High resolution crystal calorimetry at LHC

    The search for Higgs bosons above Lep200 reach could be one of the main tasks of the future pp and ee colliders. In the intermediate mass region, and in particular in the range 80-140 GeV/c2, only the 2-photon decay mode of a Higgs produced inclusively or in association with a W, gives a good chance of observation. A 'dedicated' very high resolution calorimeter with photon angle reconstruction and pion identification capability should detect a Higgs signal with high probability. A crystal calorimeter can be considered as a conservative approach to such a detector, since a large design and operation experience already exists. The extensive R and D needed for finding a dense, fast and radiation hard crystal, is under way. Guide-lines for designing an optimum calorimeter for LHC are discussed and preliminary configurations are given. (author) 7 refs., 3 figs., 2 tabs

  11. High-resolution spectrometer for atmospheric studies

    Di Carlo, Piero; Barone, Massimiliano; D'Altorio, Alfonso; Dari-Salisburgo, Cesare; Pietropaolo, Ermanno

    2009-08-01

    A high-resolution spectrometer (0.0014 nm at 313 nm) has been developed at the University of L'Aquila (Italy) for atmospheric spectroscopic studies. The layout, optics and software for the instrument control are described. Measurements of the mercury low-pressure lamp lines from 200 to 600 nm show the high performances of the spectrometer. Laboratory measurements of OH and NO2 spectrums demonstrate that the system could be used for cross-section measurements and to detect these species in the atmosphere. The first atmospheric application of the system was the observation of direct solar and sky spectrums that shows a filling-in of the sky lines due to rotational Raman scattering. The measurements have been done with clear and cloudy sky and in both there was a strong dependence of the filling-in from the solar zenith angle whereas no dependence from the wavelengths was evident at low solar zenith angles (less than 85°).

  12. Concept for a new high resolution high intensity diffractometer

    Stuhr, U. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-09-01

    A concept of a new time-of-flight powder-diffractometer for a thermal neutral beam tube at SINQ is presented. The design of the instrument optimises the contradictory conditions of high intensity and high resolution. The high intensity is achieved by using many neutron pulses simultaneously. By analysing the time-angle-pattern of the detected neutrons an assignment of the neutrons to a single pulse is possible. (author) 3 figs., tab., refs.

  13. Scanning fast and slow: current limitations of 3 Tesla functional MRI and future potential

    Roland N Boubela

    2014-02-01

    Full Text Available Functional MRI at 3T has become a workhorse for the neurosciences, e.g., neurology, psychology, and psychiatry, enabling non-invasive investigation of brain function and connectivity. However, BOLD-based fMRI is a rather indirect measure of brain function, confounded by fluctuation related signals, e.g. head or brain motion, brain pulsation, blood flow, intermixed with susceptibility differences close or distant to the region of neuronal activity. Even though a plethora of preprocessing strategies have been published to address these confounds, their efficiency is still under discussion. In particular, physiological signal fluctuations closely related to brain supply may mask BOLD signal changes related to true neuronal activation. Here we explore recent technical and methodological advancements aimed at disentangling the various components, employing fast multiband vs. standard EPI, in combination with fast temporal ICA.Our preliminary results indicate that fast (TR< 0.5s scanning may help to identify and eliminate physiologic components, increasing tSNR and functional contrast. In addition, biological variability can be studied and task performance better correlated to other measures. This should increase specificity and reliability in fMRI studies. Furthermore, physiological signal changes during scanning may then be recognized as a source of information rather than a nuisance. As we are currently still undersampling the complexity of the brain, even at a rather coarse macroscopic level, we should be very cautious in the interpretation of neuroscientific findings, in particular when comparing different groups (e.g., age, sex, medication, pathology, etc.. From a technical point of view our goal should be to sample brain activity at layer specific resolution with low TR, covering as much of the brain as possible without violating SAR limits. We hope to stimulate discussion towards a better understanding and a more quantitative use of fMRI.

  14. Scanning fast and slow: current limitations of 3 Tesla functional MRI and future potential

    Boubela, Roland N.; Kalcher, Klaudius; Nasel, Christian; Moser, Ewald

    2014-02-01

    Functional MRI at 3T has become a workhorse for the neurosciences, e.g., neurology, psychology, and psychiatry, enabling non-invasive investigation of brain function and connectivity. However, BOLD-based fMRI is a rather indirect measure of brain function, confounded by fluctuation related signals, e.g. head or brain motion, brain pulsation, blood flow, intermixed with susceptibility differences close or distant to the region of neuronal activity. Even though a plethora of preprocessing strategies have been published to address these confounds, their efficiency is still under discussion. In particular, physiological signal fluctuations closely related to brain supply may mask BOLD signal changes related to "true" neuronal activation. Here we explore recent technical and methodological advancements aimed at disentangling the various components, employing fast multiband vs. standard EPI, in combination with fast temporal ICA.Our preliminary results indicate that fast (TRbiological variability can be studied and task performance better correlated to other measures. This should increase specificity and reliability in fMRI studies. Furthermore, physiological signal changes during scanning may then be recognized as a source of information rather than a nuisance. As we are currently still undersampling the complexity of the brain, even at a rather coarse macroscopic level, we should be very cautious in the interpretation of neuroscientific findings, in particular when comparing different groups (e.g., age, sex, medication, pathology, etc.). From a technical point of view our goal should be to sample brain activity at layer specific resolution with low TR, covering as much of the brain as possible without violating SAR limits. We hope to stimulate discussion towards a better understanding and a more quantitative use of fMRI.

  15. Pyramidal fractal dimension for high resolution images

    Mayrhofer-Reinhartshuber, Michael; Ahammer, Helmut

    2016-07-01

    Fractal analysis (FA) should be able to yield reliable and fast results for high-resolution digital images to be applicable in fields that require immediate outcomes. Triggered by an efficient implementation of FA for binary images, we present three new approaches for fractal dimension (D) estimation of images that utilize image pyramids, namely, the pyramid triangular prism, the pyramid gradient, and the pyramid differences method (PTPM, PGM, PDM). We evaluated the performance of the three new and five standard techniques when applied to images with sizes up to 8192 × 8192 pixels. By using artificial fractal images created by three different generator models as ground truth, we determined the scale ranges with minimum deviations between estimation and theory. All pyramidal methods (PM) resulted in reasonable D values for images of all generator models. Especially, for images with sizes ≥1024 ×1024 pixels, the PMs are superior to the investigated standard approaches in terms of accuracy and computation time. A measure for the possibility to differentiate images with different intrinsic D values did show not only that the PMs are well suited for all investigated image sizes, and preferable to standard methods especially for larger images, but also that results of standard D estimation techniques are strongly influenced by the image size. Fastest results were obtained with the PDM and PGM, followed by the PTPM. In terms of absolute D values best performing standard methods were magnitudes slower than the PMs. Concluding, the new PMs yield high quality results in short computation times and are therefore eligible methods for fast FA of high-resolution images.

  16. High resolution CT of temporal bone trauma

    Youn, Eun Kyung [Korea General Hospital, Seoul (Korea, Republic of)

    1986-10-15

    Radiographic studies of the temporal bone following head trauma are indicated when there is cerebrospinal fluid otorrhea or rhinorrhoea, hearing loss, or facial nerve paralysis. Plain radiography displays only 17-30% of temporal bone fractures and pluridirectional tomography is both difficult to perform, particularly in the acutely ill patient, and less satisfactory for the demonstration of fine fractures. Consequently, high resolution CT is the imaging method of choice for the investigation of suspected temporal bone trauma and allows special resolution of fine bony detail comparable to that attainable by conventional tomography. Eight cases of temporal bone trauma examined at Korea General Hospital April 1985 through May 1986. The results were as follows: Seven patients (87%) suffered longitudinal fractures. In 6 patients who had purely conductive hearing loss, CT revealed various ossicular chain abnormality. In one patient who had neuro sensory hearing loss, CT demonstrated intract ossicular with a fracture nearing lateral wall of the lateral semicircular canal. In one patient who had mixed hearing loss, CT showed complex fracture.

  17. ALMA Debuts High-Resolution Results

    Kohler, Susanna

    2015-07-01

    through space as it orbits the Sun. The resolution of these images — enough to study the shape and even some surface features of the asteroid! — are unprecedented for this wavelength. HL Tau is a young star surrounded by a protoplanetary disk. ALMA's detailed observations of this region revealed remarkable structure within the disk: a series of light and dark concentric rings indicative of planets caught in the act of forming. Studying this system will help us understand how multi-planet solar systems like our own form and evolve. The star-forming galaxy SDP.81 — located so far away that the light we see was emitted when the Universe was only 15% of its current age — is gravitationally-lensed into a cosmic arc, due to the convenient placement of a nearby foreground galaxy. The combination of the lucky alignment and ALMA's high resolution grant us a spectacularly detailed view of this distant galaxy, allowing us to study its actual shape and the motion within it. The observations from ALMA's first test of its long baseline demonstrate that ALMA is capable of doing the transformational science it promised. As we gear up for the next cycle of observations, it's clear that exciting times are ahead! Citation: ALMA ship et al. 2015 ApJ 808 L1, L2, L3 and L4. Focus on the ALMA Long Baseline Campaign

  18. Differences in Velopharyngeal Structure during Speech among Asians Revealed by 3-Tesla Magnetic Resonance Imaging Movie Mode

    Kulthida Nunthayanon

    2015-01-01

    Full Text Available Objective. Different bony structures can affect the function of the velopharyngeal muscles. Asian populations differ morphologically, including the morphologies of their bony structures. The purpose of this study was to compare the velopharyngeal structures during speech in two Asian populations: Japanese and Thai. Methods. Ten healthy Japanese and Thai females (five each were evaluated with a 3-Tesla (3 T magnetic resonance imaging (MRI scanner while they produced vowel-consonant-vowel syllable (/asa/. A gradient-echo sequence, fast low-angle shot with segmented cine and parallel imaging technique was used to obtain sagittal images of the velopharyngeal structures. Results. MRI was carried out in real time during speech production, allowing investigations of the time-to-time changes in the velopharyngeal structures. Thai subjects had a significantly longer hard palate and produced shorter consonant than Japanese subjects. The velum of the Thai participants showed significant thickening during consonant production and their retroglossal space was significantly wider at rest, whereas the dimensional change during task performance was similar in the two populations. Conclusions. The 3 T MRI movie method can be used to investigate velopharyngeal function and diagnose velopharyngeal insufficiency. The racial differences may include differences in skeletal patterns and soft-tissue morphology that result in functional differences for the affected structures.

  19. A review of the safety implications of magnetic resonance imaging at field strengths of 3 Tesla and above

    Rationale: Diagnostic imaging is being driven by technological developments particularly so in the field of Magnetic Resonance Imaging (MRI). Electromagnetic fields used to produce images are becoming much stronger and switched more rapidly and it is essential that safety advice remains appropriate and current. Using a systematic methodology, this review aims to identify the clinical safety implications in performing MRI at field strengths of 3 Tesla (T) and above and determine whether the current clinical safety guidelines are appropriate. Method: References were sourced from The Cochrane Library, Centre for Reviews and Dissemination Science Direct, PubMed and Google Scholar. Related websites searched included The British Institute of Radiology, Society of Radiographers, Royal College of Radiologists, The Institution of Engineering and Technology, IMRSER (Institute for Magnetic Resonance Safety, Education, and Research), MagNet (NHS PASA). References supplied in retrieved papers were also checked for potential relevance. The use of consistent search terminology and inclusion and exclusion criteria ensured quality and provided rigour to conclusions drawn. Conclusion: According to the literature retrieved, the current body of knowledge has allowed safety guidelines to be established for patient safety and these are both appropriate and valid at field strengths of 3 T.

  20. Improved in vivo detection of cortical lesions in multiple sclerosis using double inversion recovery MR imaging at 3 Tesla

    To investigate the impact of a higher magnetic field strength of 3 Tesla (T) on the detection rate of cortical lesions in multiple sclerosis (MS) patients, in particular using a dedicated double inversion recovery (DIR) pulse sequence. Thirty-four patients with clinically isolated syndromes or definite MS were included. All patients underwent magnetic resonance imaging (MRI) at 1.5 T and 3 T, including T2-weighted turbo spin echo (TSE), fluid-attenuated inversion recovery (FLAIR) and DIR sequences. All images were analysed for focal lesions categorised according to their anatomical location. The total number of detected lesions was higher at 3 T across all pulse sequences. We observed significantly higher numbers of lesions involving the cortex at 3 T using a DIR sequence. DIR at 3 T showed 192% more pure intracortical (p < 0.001) and 30% more mixed grey matter-white matter lesions (p = 0.008). No significant increase in cortical lesions could be detected on the FLAIR and T2-weighted images. Using the T2-weighted and FLAIR sequences, significantly more lesions could be detected at 3 T in the infratentorial, periventricular and juxtacortical white matter. DIR brain MR imaging at 3 T substantially improves the sensitivity of the detection of cortical lesions compared with the standard magnetic field strength of 1.5 T. (orig.)

  1. High-resolution CT of pulmonary nodules

    This paper reports high-resolution CT correlated with inflation-fixed lung specimens in 92 consecutive patients with 94 lung nodules. The nodules included 41 adenocarcinomas, 24 squamous carcinomas, nine large cell carcinomas, seven inflammatory pseudotumors, six neuroendocrine carcinomas, and seven miscellaneous nodules. CT scans were reviewed by two independent observers without awareness of the pathologic diagnosis and then correlated with the pathologic findings. Features commonly seen in malignant and benign nodules included irregular margins, spiculation, and pleural tags. Pathologically, the irregular margins were due to nonencapsulated cellular proliferation at the periphery of the nodule. Pleural tags were due to desmoplastic reaction. Bubble lucencies (pseudocavitation) were seen most commonly in adenocarcinomas (12 of 41 [29%]), less commonly in other malignant nodules (five of 42 [12%]), and in only one of 11 benign nodules (9%). Bubble lucencies were due to patent bronchi. The authors conclude that the presence of bubble lucencies is helpful in distinguishing malignant from benign nodules

  2. Potential High Resolution Dosimeters For MRT

    Bräuer-Krisch, E.; Rosenfeld, A.; Lerch, M.; Petasecca, M.; Akselrod, M.; Sykora, J.; Bartz, J.; Ptaszkiewicz, M.; Olko, P.; Berg, A.; Wieland, M.; Doran, S.; Brochard, T.; Kamlowski, A.; Cellere, G.; Paccagnella, A.; Siegbahn, E. A.; Prezado, Y.; Martinez-Rovira, I.; Bravin, A.; Dusseau, L.; Berkvens, P.

    2010-07-01

    Microbeam Radiation Therapy (MRT) uses highly collimated, quasi-parallel arrays of X-ray microbeams of 50-600 keV, produced by 2nd and 3rd generation synchrotron sources, such as the National Synchrotron Light Source (NSLS) in the U.S., and the European Synchrotron Radiation Facility (ESRF) in France, respectively. High dose rates are necessary to deliver therapeutic doses in microscopic volumes, to avoid spreading of the microbeams by cardiosynchronous movement of the tissues. A small beam divergence and a filtered white beam spectrum in the energy range between 30 and 250 keV results in the advantage of steep dose gradients with a sharper penumbra than that produced in conventional radiotherapy. MRT research over the past 20 years has allowed a vast number of results from preclinical trials on different animal models, including mice, rats, piglets and rabbits. Microbeams in the range between 10 and 100 micron width show an unprecedented sparing of normal radiosensitive tissues as well as preferential damage to malignant tumor tissues. Typically, MRT uses arrays of narrow (˜25-100 micron-wide) microplanar beams separated by wider (100-400 microns centre-to-centre, c-t-c) microplanar spaces. We note that thicker microbeams of 0.1-0.68 mm used by investigators at the NSLS are still called microbeams, although some invesigators in the community prefer to call them minibeams. This report, however, limits it discussion to 25-100 μm microbeams. Peak entrance doses of several hundreds of Gy are surprisingly well tolerated by normal tissues. High resolution dosimetry has been developed over the last two decades, but typical dose ranges are adapted to dose delivery in conventional Radiation Therapy (RT). Spatial resolution in the sub-millimetric range has been achieved, which is currently required for quality assurance measurements in Gamma-knife RT. Most typical commercially available detectors are not suitable for MRT applications at a dose rate of 16000 Gy/s, micron

  3. Potential High Resolution Dosimeters For MRT

    Microbeam Radiation Therapy (MRT) uses highly collimated, quasi-parallel arrays of X-ray microbeams of 50-600 keV, produced by 2nd and 3rd generation synchrotron sources, such as the National Synchrotron Light Source (NSLS) in the U.S., and the European Synchrotron Radiation Facility (ESRF) in France, respectively. High dose rates are necessary to deliver therapeutic doses in microscopic volumes, to avoid spreading of the microbeams by cardiosynchronous movement of the tissues. A small beam divergence and a filtered white beam spectrum in the energy range between 30 and 250 keV results in the advantage of steep dose gradients with a sharper penumbra than that produced in conventional radiotherapy. MRT research over the past 20 years has allowed a vast number of results from preclinical trials on different animal models, including mice, rats, piglets and rabbits. Microbeams in the range between 10 and 100 micron width show an unprecedented sparing of normal radiosensitive tissues as well as preferential damage to malignant tumor tissues. Typically, MRT uses arrays of narrow (∼25-100 micron-wide) microplanar beams separated by wider (100-400 microns centre-to-centre, c-t-c) microplanar spaces. We note that thicker microbeams of 0.1-0.68 mm used by investigators at the NSLS are still called microbeams, although some invesigators in the community prefer to call them minibeams. This report, however, limits it discussion to 25-100 μm microbeams. Peak entrance doses of several hundreds of Gy are surprisingly well tolerated by normal tissues. High resolution dosimetry has been developed over the last two decades, but typical dose ranges are adapted to dose delivery in conventional Radiation Therapy (RT). Spatial resolution in the sub-millimetric range has been achieved, which is currently required for quality assurance measurements in Gamma-knife RT. Most typical commercially available detectors are not suitable for MRT applications at a dose rate of 16000 Gy/s, micron

  4. A new high-resolution TOF technology

    Fonte, Paulo J R; Williams, M C S

    2000-01-01

    In the framework of the ALICE collaboration we have recently studied the performance of multigap Resistive Plate Chambers operated in avalanche mode and at atmospheric pressure for time-of-flight measurements. The detector provided an overall (detector plus electronics) timing accuracy of 120 ps sigma at an efficiency of 98% for MIPs. The chambers had 4 gas gaps of 0.3 mm, each limited by a metallised ceramic plate and a glass plate, with an active dimension of 4'4cm2. The gas mixture contained C2H2F4+5%isobutane+10%SF6. A few percent of streamer discharges, each releasing about 20 pC, was tolerated without any noticeable inconvenience. This detector opens perspectives of affordable and reliable high granularity large area TOF detectors, with an efficiency and a time resolution comparable to existing scintillator-based TOF technology but with significantly, up to an order of magnitude, lower price per channel.

  5. High resolution tomography using analog coding

    As part of a 30-year program in the development of positron instrumentation, the authors have developed a high resolution bismuth germanate (BGO) ring tomography (PCR) employing 360 detectors and 90 photomultiplier tubes for one plane. The detectors are shaped as trapezoid and are 4 mm wide at the front end. When assembled, they form an essentially continuous cylindrical detector. Light from a scintillation in the detector is viewed through a cylindrical light pipe by the photomultiplier tubes. By use of an analog coding scheme, the detector emitting light is identified from the phototube signals. In effect, each phototube can identify four crystals. PCR is designed as a static device and does not use interpolative motion. This results in considerable advantage when performing dynamic studies. PCR is the positron tomography analog of the γ-camera widely used in nuclear medicine

  6. High resolution CT in interstitial pulmonary disease

    High-resolution CT images were assessed in 39 patients with confirmed interstitial lung disease. 22 patients with fibrosing alveolitis, 12 patients with lymphangitic spread of tumour and 5 patients with lymphangioleiomyomatosis of the lung were included. In fibrosing alveolitis the dominant features on HR-CT were honeycomb cysts with concomitant fibrosis in a predominantly peripheral subpleural distribution. In contrast to this the patients with LAM showed cystic lesions without any predominance - throughout the lung fields and without any fibrotic changes. In lymphangitic spread of tumour, polygonal lines and septal lines as well as nodules were found along the bronchovascular bundles. The patterns seen on HR-CT of the thorax correlate extremely well with the underlying pathology and make it possible to differentiate between the three disease entities by means of characteristic features. (orig.)

  7. High resolution observations of iota Herculis

    Iota Her (B3 IV) has been known for a long time as a spectrum variable. Smith and Smith and Stern detected different periods in line profile variations and classified iota Her in their 53 Per group. Recently the Nice group and S. Gonzalez-Bedolla in Mexico observed it in photometry and spectrography at 12 A/mm. The main results are the detection of short period variations (0.12 or 0.14 day period) in photometry, radial velocity and on the He I 4387/Mg II 4481 lines intensity ratio. These short periodic variations are superimposed on longer ones which were first detected by Rogerson. The authors present here preliminary results of the 1985 campaign obtained with very high spectral resolution

  8. High resolution imaging detectors and applications

    Saha, Swapan K

    2015-01-01

    Interferometric observations need snapshots of very high time resolution of the order of (i) frame integration of about 100 Hz or (ii) photon-recording rates of several megahertz (MHz). Detectors play a key role in astronomical observations, and since the explanation of the photoelectric effect by Albert Einstein, the technology has evolved rather fast. The present-day technology has made it possible to develop large-format complementary metal oxide–semiconductor (CMOS) and charge-coupled device (CCD) array mosaics, orthogonal transfer CCDs, electron-multiplication CCDs, electron-avalanche photodiode arrays, and quantum-well infrared (IR) photon detectors. The requirements to develop artifact-free photon shot noise-limited images are higher sensitivity and quantum efficiency, reduced noise that includes dark current, read-out and amplifier noise, smaller point-spread functions, and higher spectral bandwidth. This book aims to address such systems, technologies and design, evaluation and calibration, control...

  9. High-resolution CT in diffuse panbronchiolitis

    High-resolution CT (HRCT) of twenty patients with diffuse panbronchiolitis was reviewed to evaluate the correlation with the stage and pulmonary function. The most basic finding was diffuse small nodules, observed in all twenty patients. Of all HRCT findings diffuse small nodules correlated with %FEV 1 and PaO2 (p 2 and PaCO2 (p < 0.05). Multivariate analysis among HRCT features concerning the stage showed that involvement of thin subpleural area (SSA) was the most contributory finding (partial cor. = 0.70830) to the advanced state (stage 3) with statistically significant difference (p < 0.05). The finding concerned with such spared thin subpleural area is an important diagnostic clue in stage 3 as well as a clinical evidence of infection with Pseudomonas aeruginosa. According to this review, HRCT is considered to be an effective and promising modality in the evaluation of diffuse panbronchiolitis. (author)

  10. High-resolution transcriptome of human macrophages.

    Marc Beyer

    Full Text Available Macrophages are dynamic cells integrating signals from their microenvironment to develop specific functional responses. Although, microarray-based transcriptional profiling has established transcriptional reprogramming as an important mechanism for signal integration and cell function of macrophages, current knowledge on transcriptional regulation of human macrophages is far from complete. To discover novel marker genes, an area of great need particularly in human macrophage biology but also to generate a much more thorough transcriptome of human M1- and M1-like macrophages, we performed RNA sequencing (RNA-seq of human macrophages. Using this approach we can now provide a high-resolution transcriptome profile of human macrophages under classical (M1-like and alternative (M2-like polarization conditions and demonstrate a dynamic range exceeding observations obtained by previous technologies, resulting in a more comprehensive understanding of the transcriptome of human macrophages. Using this approach, we identify important gene clusters so far not appreciated by standard microarray techniques. In addition, we were able to detect differential promoter usage, alternative transcription start sites, and different coding sequences for 57 gene loci in human macrophages. Moreover, this approach led to the identification of novel M1-associated (CD120b, TLR2, SLAMF7 as well as M2-associated (CD1a, CD1b, CD93, CD226 cell surface markers. Taken together, these data support that high-resolution transcriptome profiling of human macrophages by RNA-seq leads to a better understanding of macrophage function and will form the basis for a better characterization of macrophages in human health and disease.

  11. HR 3 tesla MRI for the diagnosis of endolymphatic hydrops and differential diagnosis of inner ear tumors. Demonstrated by two cases with similar symptoms

    Homann, G.; Fahrendorf, D.; Niederstadt, T.; Nagelmann, N.; Heindel, W.; Vieth, V. [University Hospital Muenster (Germany). Dept. of Clinical Radiology; Luetkenhoener, B.; Boeckenfeld, Y.; Basel, T. [University Hospital Muenster (Germany). ENT Clinic

    2014-03-15

    The synchronous appearance of different inner ear pathologies with a nearly equivalent clinical manifestation such as Meniere's disease and vestibular schwannoma is very rare but leads to a relevant dilemma concerning therapy options. MRI is the method of choice to detect intralabyrinthine tumors. Since endolymphatic hydrops is considered the morphological equivalent of Meniere's disease, magnetic resonance imaging including hT2w-FLAIR sequences 4 h after i.v. administration of gadolinium-based contrast agents (GBCA) allows the diagnosis and grading of endolymphatic hydrops in vivo synchronous to diagnosis and monitoring of ILT. To this day, only a few cases of intralabyrinthine schwannoma could be shown to appear simultaneously with endolymphatic hydrops by MRI, but to our knowledge the dedicated distinction of endolymphatic space has not been previously demonstrated. The aim of this work was not only to detect the coincidence of endolymphatic hydrops and vestibular schwannoma, but also to differentiate tumor tissue from endolymphatic space by 3 Tesla MRI. This enables therapy options that are originally indicated for Meniere's disease. The aim of this work was to describe the feasibility and usefulness of endolymphatic hydrops MRI on intralabyrinthal tumors in a special case of intravestibular schwannoma to demonstrate the high clinical relevance and impact in therapeutic decision-making for the synchronous appearance of endolymphatic hydrops and intralabyrinthine tumors. Therefore, we present a typical case of Meniere's disease in contrast to a patient with an intralabyrinthine schwannoma and Meniere's-like symptoms. (orig.)

  12. High-throughput high-resolution cryo-electron crystallography

    Scherer, Sebastian

    2015-01-01

    High-resolution structures of membrane and soluble proteins can be obtained by cryo-electron crystallography, given highly-ordered cryo-preparations of perfectly flat 2D crystals are available. Studies of membrane proteins, which are embedded into a lipid membrane, mimicking the native cell membrane, are of particular biological interest. However there are multiple reasons why electron crystallography is far from being a mainstream protein structure determination technique. In this thesis we ...

  13. 96-Channel Receive-Only Head Coil for 3 Tesla: Design Optimization and Evaluation

    Wiggins, Graham C.; Polimeni, Jonathan R; Potthast, Andreas; Schmitt, Melanie; Alagappan, Vijay; Wald, Lawrence L.

    2009-01-01

    The benefits and challenges of highly parallel array coils for head imaging were investigated through the development of a 3T receive-only phased-array head coil with 96 receive elements constructed on a close-fitting helmet-shaped former. We evaluated several designs for the coil elements and matching circuitry, with particular attention to sources of signal-to-noise ratio (SNR) loss, including various sources of coil loading and coupling between the array elements. The SNR and noise amplifi...

  14. Toward high-resolution optoelectronic retinal prosthesis

    Palanker, Daniel; Huie, Philip; Vankov, Alexander; Asher, Alon; Baccus, Steven

    2005-04-01

    It has been already demonstrated that electrical stimulation of retina can produce visual percepts in blind patients suffering from macular degeneration and retinitis pigmentosa. Current retinal implants provide very low resolution (just a few electrodes), while several thousand pixels are required for functional restoration of sight. We present a design of the optoelectronic retinal prosthetic system that can activate a retinal stimulating array with pixel density up to 2,500 pix/mm2 (geometrically corresponding to a visual acuity of 20/80), and allows for natural eye scanning rather than scanning with a head-mounted camera. The system operates similarly to "virtual reality" imaging devices used in military and medical applications. An image from a video camera is projected by a goggle-mounted infrared LED-LCD display onto the retina, activating an array of powered photodiodes in the retinal implant. Such a system provides a broad field of vision by allowing for natural eye scanning. The goggles are transparent to visible light, thus allowing for simultaneous utilization of remaining natural vision along with prosthetic stimulation. Optical control of the implant allows for simple adjustment of image processing algorithms and for learning. A major prerequisite for high resolution stimulation is the proximity of neural cells to the stimulation sites. This can be achieved with sub-retinal implants constructed in a manner that directs migration of retinal cells to target areas. Two basic implant geometries are described: perforated membranes and protruding electrode arrays. Possibility of the tactile neural stimulation is also examined.

  15. Development of a 3 tesla - 10 Hz pulsed magnet-modulator system

    In order to support the experimental work done at the Los Alamos Meson Physics Facility new instrumentation and data collection systems of advanced design are developed on a regular basis. Within the instrumentation system for an experiment at LAMPF, The Photo-Excitation of the H- Ion Resonances, there exists a need for a pulsed air-core electromagnet and modulator system. The magnet must be capable of producing a field strength of 0 to 3T in a volume of 3.5 cm3. In addition it must be radiation resistant, have a uniform field, operate in a high vacuum with little or no outgassing, and the physical layout of the magnet must provide minimal azimuthal obstruction to both the ion and laser beams. The modulator must be capable of producing up to a 15KA pulse with duration of two μs at a maximum repetition rate of 10 Hz. Modulator layout must be extremely reliable so that data collection time is not lost during the experiment. This paper describes in detail the development of the system

  16. High Resolution Airborne Shallow Water Mapping

    Steinbacher, F.; Pfennigbauer, M.; Aufleger, M.; Ullrich, A.

    2012-07-01

    In order to meet the requirements of the European Water Framework Directive (EU-WFD), authorities face the problem of repeatedly performing area-wide surveying of all kinds of inland waters. Especially for mid-sized or small rivers this is a considerable challenge imposing insurmountable logistical efforts and costs. It is therefore investigated if large-scale surveying of a river system on an operational basis is feasible by employing airborne hydrographic laser scanning. In cooperation with the Bavarian Water Authority (WWA Weilheim) a pilot project was initiated by the Unit of Hydraulic Engineering at the University of Innsbruck and RIEGL Laser Measurement Systems exploiting the possibilities of a new LIDAR measurement system with high spatial resolution and high measurement rate to capture about 70 km of riverbed and foreland for the river Loisach in Bavaria/Germany and the estuary and parts of the shoreline (about 40km in length) of lake Ammersee. The entire area surveyed was referenced to classic terrestrial cross-section surveys with the aim to derive products for the monitoring and managing needs of the inland water bodies forced by the EU-WFD. The survey was performed in July 2011 by helicopter and airplane and took 3 days in total. In addition, high resolution areal images were taken to provide an optical reference, offering a wide range of possibilities on further research, monitoring, and managing responsibilities. The operating altitude was about 500 m to maintain eye-safety, even for the aided eye, the airspeed was about 55 kts for the helicopter and 75 kts for the aircraft. The helicopter was used in the alpine regions while the fixed wing aircraft was used in the plains and the urban area, using appropriate scan rates to receive evenly distributed point clouds. The resulting point density ranged from 10 to 25 points per square meter. By carefully selecting days with optimum water quality, satisfactory penetration down to the river bed was achieved

  17. A 10 Kelvin 3 Tesla Magnet for Space Flight ADR Systems

    Tuttle, Jim; Shirron, Peter; Canavan, Edgar; DiPirro, Michael; Riall, Sara; Pourrahimi, Shahin

    2003-01-01

    Many future space flight missions are expected to use adiabatic demagnetization refrigerators (ADRs) to reach detector operating temperatures well below one Kelvin. The goal is to operate each ADR with a mechanical cooler as its heat sink, thus avoiding the use of liquid cryogens. Although mechanical coolers are being developed to operate at temperatures of 6 Kelvin and below, there is a large efficiency cost associated with operating them at the bottom of their temperature range. For the multi-stage ADR system being developed at Goddard Space Flight Center, the goal is to operate with a 10 Kelvin mechanical cooler heat sink. With currently available paramagnetic materials, the highest temperature ADR stage in such a system will require a magnetic field of approximately three Tesla. Thus the goal is to develop a small, lightweight three Tesla superconducting magnet for operation at 10 Kelvin. It is important that this magnet have a low current/field ratio. Because traditional NbTi magnets do not operate safely above about six Kelvin, a magnet with a higher Tc is required. The primary focus has been on Nb3Sn magnets. Since standard Nb3Sn wire must be coated with thick insulation, wound on a magnet mandrel and then reacted, standard Nb,Sn magnets are quite heavy and require high currents Superconducting Systems developed a Nb3Sn wire which can be drawn down to small diameter, reacted, coated with thin insulation and then wound on a small diameter coil form. By using this smaller wire and operating closer to the wire s critical current, it should be possible to reduce the mass and operating current of 10 Kelvin magnets. Using this "react-then-wind" technology, Superconducting Systems has produced prototype 10 Kelvin magnets. This paper describes the development and testing of these magnets and discusses the outlook for including 10 Kelvin magnets on space-flight missions.

  18. Chemical shift imaging at 3 Tesla: effect of echo time on assessing bone marrow abnormalities

    Our purpose is to test the effect of varied in-phase (IP) and opposed-phase (OP) sequence order on characterizing marrow signal changes at 3T. The study was HIPAA compliant and IRB approved. Informed consent was waived. At 3T, IP and OP sequences were acquired in three patients with biopsy-proven osteosarcomas, using two methods: approach 1 (OP acquisition before IP acquisition) and approach 2 (OP after IP). Signal intensity (SI) measurements in 12 locations of biopsy-proven osteosarcoma and in six locations with normal bone marrow were performed independently by two experienced musculoskeletal radiologists. The signal intensity ratio (SIR) was measured within the marrow where there was T1 signal lower than skeletal muscle. A SIR = 20 % was considered negative. Interobserver agreement was measured by the Lin concordance correlation coefficient (CCC). In 75 % (18/24) of locations within the biopsy-proven tumors, the SIR was >20 % (SI drop more than 20 % in OP compared to IP) using approach 2 and in 100 % (24/24) of the locations the SIR was <20 % (SI drop less than 20 % in OP compared to IP) using approach 1, indicating a high percentage of false-negative results by approach 2, and no false-negative results with approach 1. There was good agreement between observer measurement (CCC = 0.96). At 3T, the OP sequence should be acquired prior to the IP sequence, because susceptibility artifacts on a later-acquired OP sequence may lead to an erroneous interpretation of marrow signal abnormalities. (orig.)

  19. Automatic abundance analysis of high resolution spectra

    Bonifacio, P; Bonifacio, Piercarlo; Caffau, Elisabetta

    2003-01-01

    We describe an automatic procedure for determining abundances from high resolution spectra. Such procedures are becoming increasingly important as large amounts of data are delivered from 8m telescopes and their high-multiplexing fiber facilities, such as FLAMES on ESO-VLT. The present procedure is specifically targeted for the analysis of spectra of giants in the Sgr dSph; however, the procedure may be, in principle, tailored to analyse stars of any type. Emphasis is placed on the algorithms and on the stability of the method; the external accuracy rests, ultimately, on the reliability of the theoretical models (model-atmospheres, synthetic spectra) used to interpret the data. Comparison of the results of the procedure with the results of a traditional analysis for 12 Sgr giants shows that abundances accurate at the level of 0.2 dex, comparable with that of traditional analysis of the same spectra, may be derived in a fast and efficient way. Such automatic procedures are not meant to replace the traditional ...

  20. Logging Data High-Resolution Sequence Stratigraphy

    Li Hongqi; Xie Yinfu; Sun Zhongchun; Luo Xingping

    2006-01-01

    The recognition and contrast of bed sets in parasequence is difficult in terrestrial basin high-resolution sequence stratigraphy. This study puts forward new methods for the boundary identification and contrast of bed sets on the basis of manifold logging data. The formation of calcareous interbeds, shale resistivity differences and the relation of reservoir resistivity to altitude are considered on the basis of log curve morphological characteristics, core observation, cast thin section, X-ray diffraction and scanning electron microscopy. The results show that the thickness of calcareous interbeds is between 0.5 m and 2 m, increasing on weathering crusts and faults. Calcareous interbeds occur at the bottom of Reservoir resistivity increases with altitude. Calcareous interbeds may be a symbol of recognition for the boundary of bed sets and isochronous contrast bed sets, and shale resistivity differences may confirm the stack relation and connectivity of bed sets. Based on this, a high-rcsolution chronostratigraphic framework of Xi-1 segment in Shinan area, Junggar basin is presented, and the connectivity of bed sets and oil-water contact is confirmed. In this chronostratigraphic framework, the growth order, stack mode and space shape of bed sets are qualitatively and quantitatively described.

  1. High Resolution Image Reconstruction from Projection of Low Resolution Images DIffering in Subpixel Shifts

    Mareboyana, Manohar; Le Moigne-Stewart, Jacqueline; Bennett, Jerome

    2016-01-01

    In this paper, we demonstrate a simple algorithm that projects low resolution (LR) images differing in subpixel shifts on a high resolution (HR) also called super resolution (SR) grid. The algorithm is very effective in accuracy as well as time efficiency. A number of spatial interpolation techniques using nearest neighbor, inverse-distance weighted averages, Radial Basis Functions (RBF) etc. used in projection yield comparable results. For best accuracy of reconstructing SR image by a factor of two requires four LR images differing in four independent subpixel shifts. The algorithm has two steps: i) registration of low resolution images and (ii) shifting the low resolution images to align with reference image and projecting them on high resolution grid based on the shifts of each low resolution image using different interpolation techniques. Experiments are conducted by simulating low resolution images by subpixel shifts and subsampling of original high resolution image and the reconstructing the high resolution images from the simulated low resolution images. The results of accuracy of reconstruction are compared by using mean squared error measure between original high resolution image and reconstructed image. The algorithm was tested on remote sensing images and found to outperform previously proposed techniques such as Iterative Back Projection algorithm (IBP), Maximum Likelihood (ML), and Maximum a posterior (MAP) algorithms. The algorithm is robust and is not overly sensitive to the registration inaccuracies.

  2. Improved characterisation of stroke phenotype using sequential MR diffusion tensor imaging at 3 tesla

    Full text: MR diffusion weighted imaging (DWI) enables the identification of early ischemia in acute stroke. Recent advances in DWI allow the identification of anisotropic white matter tracts with diffusion tensor imaging (DTI).We used DTI to study patients with recent stroke in a high field MR system to establish the type of phenotypic abnormalities demonstrated and to determine whether DTI could produce an alternative tool that might be used in studies of clinical outcome and recovery. 25 patients with recent stroke were imaged at 3 Telsa. The extent of abnormality on the conventional and tensor images were compared. Regions of interest were drawn within the area of ischemia and in the contralateral hemisphere. The relative anisotropy index for these areas was calculated and compared. DTI studies were repeated in 11 patients at 1 week and 8 patients at 3 months. DTI was successfully performed in 21 patients. There were 21 men, mean age 58 years (range 25-86 years) imaged at a median of 1 day (range 6 hours to 14 days) from the known time of stroke onset. 19/21 patients demonstrated DWI changes on the b = 1000s/mm2 trace image. DTI imaging was initially normal in 6 patients. The abnormalities consisted of actual disruption of white matter tracts in 13 patients. Ansiotropy indices were reduced to 0.21 in the ischaemic areas compared with 0.34 in normal appearing contralateral white matter (p = 0.016). 2 patients demonstrated distortion of white matter tracts around ischemia induced mass effect. One patient without tract disruption initially had progressed to tract disruption when re-imaged six days from stroke onset. A further patient had distortion of white matter tracts around an infarct and had a good clinical outcome. DTI is able to quantify the extent of white matter tract disruption in acute stroke. The extent or lack of tract destruction may be prognostically important as it provides information that is not available with conventional diffusion or perfusion

  3. High resolution rainfall measurements around a high rise building

    de Jong, Stijn; van de Giesen, Nick; Hut, Rolf

    2010-05-01

    A number of disdrometers (acoustic rain gauge) has been placed around a high rise building on a place where variation in spatial distribution of precipitation is expected, to show the advantage of high resolution rainfall measurements in a urban area. The standard recommendation for the placement of a rain gauge is that the gauge is positioned at a distance corresponding to two to four times the height of any nearby obstruction to obtain a measurement that is representative for the surrounding area. In an urban area it is almost impossible to find a location that suits this recommendation. Rain measurements in urban area with a high spatial resolution are desired, to obtain a better understanding of urban hydrology, but costs may be prohibitive. A low cost disdrometer has been developed to make it affordable to perform rain measurements with a very high spatial and temporal resolution. The disdrometer is tested around a high rise building on the Delft University of Technology campus. The faculty of Electrical Engineering, Mathematics and Computer Science (EWI) on the campus of Delft University of Technology consists of a high rise building of 90 meters and a low rise building of 15 meters. Sensors are placed on the low rise building to measure the impact of the high rise building on the spatial distribution of precipitation. In addition to the disdrometer, two other methods are used to measure precipitation differences around the high rise building. Tipping bucket rain gauges have been placed on two elevator shaft housings on the low rise building, of which one is situated in the shadow of the high rise building. Simultaneously, runoff from the elevator shafts is measured. A comparison of the different methods will be presented.

  4. A method for generating high resolution satellite image time series

    Guo, Tao

    2014-10-01

    There is an increasing demand for satellite remote sensing data with both high spatial and temporal resolution in many applications. But it still is a challenge to simultaneously improve spatial resolution and temporal frequency due to the technical limits of current satellite observation systems. To this end, much R&D efforts have been ongoing for years and lead to some successes roughly in two aspects, one includes super resolution, pan-sharpen etc. methods which can effectively enhance the spatial resolution and generate good visual effects, but hardly preserve spectral signatures and result in inadequate analytical value, on the other hand, time interpolation is a straight forward method to increase temporal frequency, however it increase little informative contents in fact. In this paper we presented a novel method to simulate high resolution time series data by combing low resolution time series data and a very small number of high resolution data only. Our method starts with a pair of high and low resolution data set, and then a spatial registration is done by introducing LDA model to map high and low resolution pixels correspondingly. Afterwards, temporal change information is captured through a comparison of low resolution time series data, and then projected onto the high resolution data plane and assigned to each high resolution pixel according to the predefined temporal change patterns of each type of ground objects. Finally the simulated high resolution data is generated. A preliminary experiment shows that our method can simulate a high resolution data with a reasonable accuracy. The contribution of our method is to enable timely monitoring of temporal changes through analysis of time sequence of low resolution images only, and usage of costly high resolution data can be reduces as much as possible, and it presents a highly effective way to build up an economically operational monitoring solution for agriculture, forest, land use investigation

  5. Resolution enhancement of low quality videos using a high-resolution frame

    Pham, T.Q.; Van Vliet, L.J.; Schutte, K.

    2006-01-01

    This paper proposes an example-based Super-Resolution (SR) algorithm of compressed videos in the Discrete Cosine Transform (DCT) domain. Input to the system is a Low-Resolution (LR) compressed video together with a High-Resolution (HR) still image of similar content. Using a training set of correspo

  6. The High Time Resolution Radio Sky

    Thornton, D.

    2013-11-01

    Pulsars are laboratories for extreme physics unachievable on Earth. As individual sources and possible orbital companions can be used to study magnetospheric, emission, and superfluid physics, general relativistic effects, and stellar and binary evolution. As populations they exhibit a wide range of sub-types, with parameters varying by many orders of magnitude signifying fundamental differences in their evolutionary history and potential uses. There are currently around 2200 known pulsars in the Milky Way, the Magellanic clouds, and globular clusters, most of which have been discovered with radio survey observations. These observations, as well as being suitable for detecting the repeating signals from pulsars, are well suited for identifying other transient astronomical radio bursts that last just a few milliseconds that either singular in nature, or rarely repeating. Prior to the work of this thesis non-repeating radio transients at extragalactic distances had possibly been discovered, however with just one example status a real astronomical sources was in doubt. Finding more of these sources was a vital to proving they were real and to open up the universe for millisecond-duration radio astronomy. The High Time Resolution Universe survey uses the multibeam receiver on the 64-m Parkes radio telescope to search the whole visible sky for pulsars and transients. The temporal and spectral resolution of the receiver and the digital back-end enable the detection of relatively faint, and distant radio sources. From the Parkes telescope a large portion of the Galactic plane can be seen, a rich hunting ground for radio pulsars of all types, while previously poorly surveyed regions away from the Galactic plane are also covered. I have made a number of pulsar discoveries in the survey, including some rare systems. These include PSR J1226-6208, a possible double neutron star system in a remarkably circular orbit, PSR J1431-471 which is being eclipsed by its companion with

  7. High-speed segmentation-driven high-resolution matching

    Ekstrand, Fredrik; Ahlberg, Carl; Ekström, Mikael; Spampinato, Giacomo

    2015-02-01

    This paper proposes a segmentation-based approach for matching of high-resolution stereo images in real time. The approach employs direct region matching in a raster scan fashion influenced by scanline approaches, but with pixel decoupling. To enable real-time performance it is implemented as a heterogeneous system of an FPGA and a sequential processor. Additionally, the approach is designed for low resource usage in order to qualify as part of unified image processing in an embedded system.

  8. Diagnostic accuracy of a short-duration 3 Tesla magnetic resonance protocol for diagnosing stifle joint lesions in dogs with non-traumatic cranial cruciate ligament rupture

    Galindo-Zamora, Vladimir; Dziallas, Peter; Ludwig, Davina C; Nolte, Ingo; Wefstaedt, Patrick

    2013-01-01

    Background Magnetic resonance (MR) imaging is the preferred diagnostic tool to evaluate internal disorders of many joints in humans; however, the usefulness of MR imaging in the context of osteoarthritis, and joint disease in general, has yet to be characterized in veterinary medicine. The objective of this study was to assess the diagnostic accuracy of short-duration 3 Tesla MR imaging for the evaluation of cranial and caudal cruciate ligament, meniscal and cartilage damage, as well as the d...

  9. Initial Experience of 3-Tesla Apparent Diffusion Coefficient Values in Characterizing Squamous Cell Carcinomas of the Head and Neck

    Background: With the increased clinical use of 3-Tesla (3T) magnets, it becomes important to identify the potential applications of advanced magnetic resonance (MR) imaging techniques such as diffusion-weighted imaging in head and neck pathologies. Purpose: To establish the 3T apparent diffusion coefficient (ADC) values for normal neck structures, and to examine the utility of ADC values in distinguishing head and neck squamous cell carcinomas (HNSCC) from normal neck anatomy. Material and Methods: 3T diffusion-weighted imaging was performed on 10 normal volunteers and 10 patients with known HNSCC. In the volunteers, mean ADC was calculated in the parotid gland, submandibular gland, base of the tongue, pterygoid muscle, masseter muscle, paraspinal muscles, true vocal cord, thyroid gland, thyroid cartilage, cricoid cartilage, and lymph nodes. The mean tumor ADC value was calculated from the 10 patients with HNSCC and compared with the normal ADC values from various neck structures. Results: The mean ADC value measured in the HNSCC was 1.101 (±0.214)x10-3mm2/s. This was significantly lower than ADC values of paraspinal muscles, pterygoid muscle, masseter muscle, thyroid gland, and base of the tongue (P=0.0006, 0.0002, 0.0001, 0.001, and 0.002, respectively). The tumor ADC values were not significantly different from ADC values of parotid and submandibular glands (P=0.057 and 0.14, respectively). Conclusion: 3T ADC values show potential for distinguishing HNSCC from normal extracranial head and neck structures

  10. High resolution simulations of nonhelical MHD turbulence

    Haugen, N E L; Dobler, W; Haugen, Nils Erland L.; Brandenburg, Axel; Dobler, Wolfgang

    2003-01-01

    According to the kinematic theory of nonhelical dynamo action the magnetic energy spectrum increases with wavenumber and peaks at the resistive cutoff wavenumber. It has previously been argued that even in the dynamical case the magnetic energy peaks at the resistive scale. Using high resolution simulations (up to 1024^3 meshpoints) with no large scale imposed field we show that the magnetic energy peaks at a wavenumber that is independent of the magnetic Reynolds number and about 5 times larger than the forcing wavenumber. Throughout the inertial range the spectral magnetic energy exceeds the kinetic energy by a factor of 2 to 3. Both spectra are approximately parallel. The total energy spectrum seems to be close to k^{-3/2}, but there is a strong bottleneck effect and it is suggested that the asymptotic spectrum is instead k^{-5/3}. This is supported by the value of the second order structure function exponent that is found to be zeta_2=0.70, suggesting a k^{-1.70} spectrum. The third order structure functi...

  11. AIRBORNE HIGH-RESOLUTION DIGITAL IMAGING SYSTEM

    Prado-Molina, J.

    2006-04-01

    Full Text Available A low-cost airborne digital imaging system capable to perform aerial surveys with small-format cameras isintroduced. The equipment is intended to obtain high-resolution multispectral digital photographs constituting so aviable alternative to conventional aerial photography and satellite imagery. Monitoring software handles all theprocedures involved in image acquisition, including flight planning, real-time graphics for aircraft position updatingin a mobile map, and supervises the main variables engaged in the imaging process. This software also creates fileswith the geographical position of the central point of every image, and the flight path followed by the aircraftduring the entire survey. The cameras are mounted on a three-axis stabilized platform. A set of inertial sensorsdetermines platform's deviations independently from the aircraft and an automatic control system keeps thecameras at a continuous nadir pointing and heading, with a precision better than ± 1 arc-degree in three-axis. Thecontrol system is also in charge of saving the platform’s orientation angles when the monitoring software triggersthe camera. These external orientation parameters, together with a procedure for camera calibration give theessential elements for image orthocorrection. Orthomosaics are constructed using commercial GIS software.This system demonstrates the feasibility of large area coverage in a practical and economical way using smallformatcameras. Monitoring and automatization reduce the work while increasing the quality and the amount ofuseful images.

  12. High spatial resolution probes for neurobiology applications

    Position-sensitive biological neural networks, such as the brain and the retina, require position-sensitive detection methods to identify, map and study their behavior. Traditionally, planar microelectrodes have been employed to record the cell's electrical activity with device limitations arising from the electrode's 2-D nature. Described here is the development and characterization of an array of electrically conductive micro-needles aimed at addressing the limitations of planar electrodes. The capability of this array to penetrate neural tissue improves the electrode-cell electrical interface and allows more complicated 3-D networks of neurons, such as those found in brain slices, to be studied. State-of-the-art semiconductor fabrication techniques were used to etch and passivate conformally the metal coat and fill high aspect ratio holes in silicon. These are subsequently transformed into needles with conductive tips. This process has enabled the fabrication of arrays of unprecedented dimensions: 61 hexagonally close-packed electrodes, ∼200 μm tall with 60 μm spacing. Electroplating the tungsten tips with platinum ensure suitable impedance values (∼600 kΩ at 1 kHz) for the recording of neuronal signals. Without compromising spatial resolution of the neuronal recordings, this array adds a new and exciting dimension to the study of biological neural networks.

  13. High-resolution ophthalmic imaging system

    Olivier, Scot S.; Carrano, Carmen J.

    2007-12-04

    A system for providing an improved resolution retina image comprising an imaging camera for capturing a retina image and a computer system operatively connected to the imaging camera, the computer producing short exposures of the retina image and providing speckle processing of the short exposures to provide the improved resolution retina image. The system comprises the steps of capturing a retina image, producing short exposures of the retina image, and speckle processing the short exposures of the retina image to provide the improved resolution retina image.

  14. Characteristics of carotid atherosclerotic plaques of chronic lipid apheresis patients as assessed by In Vivo High-Resolution CMR - a comparative analysis

    Grimm Jochen M

    2012-11-01

    Full Text Available Abstract Background Components of carotid atherosclerotic plaques can reliably be identified and quantified using high resolution in vivo 3-Tesla CMR. It is suspected that lipid apheresis therapy in addition to lowering serum lipid levels also has an influence on development and progression of atherosclerotic plaques. The purpose of this study was to evaluate the influence of chronic lipid apheresis (LA on the composition of atherosclerotic carotid plaques. Methods 32 arteries of 16 patients during chronic LA-therapy with carotid plaques and stenosis of 1–80% were matched according to degree of stenosis with 32 patients, who had recently suffered an ischemic stroke. Of these patients only the asymptomatic carotid artery was analyzed. All patients underwent black-blood 3 T CMR of the carotids using parallel imaging and dedicated surface coils. Cardiovascular risk factors were recorded. Morphology and composition of carotid plaques were evaluated. For statistical evaluation Fisher’s Exact and unpaired t-test were used. A p-value Results Patients in the LA-group were younger (63.5 vs. 73.9. years, p2, p Conclusion Results of this study suggest that, despite a severer risk profile for cardiovascular complications in LA-patients, chronic LA is associated with significantly lower lipid content in carotid plaques compared to plaques of patients without LA with similar degrees of stenosis, which is characteristic of clinically stable plaques.

  15. A high resolution β-detector

    We present a detector which associates a charge coupled device to a light amplifier. This image sensor must detect weak β-activity, with a 10 μm resolution and should replace the autoradiographic films used for molecular hybridization. The best results are obtained with the 35S emittor, for which the resolution and the efficiency are respectively 20 μm and 100% (relative to the measured standard source)

  16. Single sensor processing to obtain high resolution color component signals

    Glenn, William E. (Inventor)

    2010-01-01

    A method for generating color video signals representative of color images of a scene includes the following steps: focusing light from the scene on an electronic image sensor via a filter having a tri-color filter pattern; producing, from outputs of the sensor, first and second relatively low resolution luminance signals; producing, from outputs of the sensor, a relatively high resolution luminance signal; producing, from a ratio of the relatively high resolution luminance signal to the first relatively low resolution luminance signal, a high band luminance component signal; producing, from outputs of the sensor, relatively low resolution color component signals; and combining each of the relatively low resolution color component signals with the high band luminance component signal to obtain relatively high resolution color component signals.

  17. The NASA High Resolution Microwave Survey

    Tarter, J. C.; Gulkis, S.

    1993-05-01

    The NASA High Resolution Microwave Survey (HRMS) began a decade of planned observations to search for signals of extraterrestrial intelligent origin with inaugural ceremonies at two sites on October 12, 1992. At Goldstone, California the Sky Survey began executing precisely controlled scanning patterns on the celestial sphere using a new beam waveguide 34m antenna operating at a frequency near 8500 MHz (X-band). At Arecibo, Puerto Rico the Targeted Search began tracking GL615.1A, one of 24 solar-type stars selected for these inaugural observations, using the NAIC 300m radio telescope operating in a band of frequencies centered at 1406 MHz. Since the initiation of the search, the Sky Survey has completed X-band observations of several dozen sky-frames measuring 30(deg) times 1.5(deg) . In addition, observations of selected areas of the galactic plane have been observed in several frequency bands (1400 MHz and 1600 MHz) using a 26m antenna located near the 34m antenna. The Targeted Search has completed the first 200 hours of observations at Arecibo covering some 300 MHz of bandwidth. This paper summarizes the results of the observations to date, including a synopsis of the interference observed at the Goldstone and Arecibo sites, and a discussion of techniques that will be used to improve future observations. The HRMS program is managed by the Ames Research Center in collaboration with the Jet Propulsion Laboratory. The results presented in this paper represent the efforts of a team of scientists and engineers at these two institutions as well as the SETI Institute, Silicon Engines Inc., John C. Reykjalin Inc., Sverdrup Technology, Sterling Federal Systems, Cornell University, the Harvard-Smithsonian Center for Astrophysics, the American Astronomical Society, Arecibo Observatory, UC Santa Cruz, the University of Washington, UC Berkeley, California Institute of Technology, Georgia Institute of Technology, Innovative Systems, and the Space Telescope Science Institute.

  18. Zeolites - a high resolution electron microscopy study

    High resolution transmission electron microscopy (HRTEM) has been used to investigate a number of zeolites (EMT, FAU, LTL, MFI and MOR) and a member of the mesoporous M41S family. The electron optical artefact, manifested as a dark spot in the projected centre of the large zeolite channels, caused by insufficient transfer of certain reflections in the objective lens has been explained. The artefact severely hinders observation of materials confined in the zeolite channels and cavities. It is shown how to circumvent the artefact problem and how to image confined materials in spite of disturbance caused by the artefact. Image processing by means of a Wiener filter has been applied for removal of the artefact. The detailed surface structure of FAU has been investigated. Comparison of experimental micrographs with images simulated using different surface models indicates that the surface can be terminated in different ways depending on synthesis methods. The dealuminated form of FAU (USY) is covered by an amorphous region. Platinum incorporated in FAU has a preponderance to aggregate in the (111) twin planes, probably due to a local difference in cage structure with more spacious cages. It is shown that platinum is intra-zeolitic as opposed to being located on the external surface of the zeolite crystal. This could be deduced from tomography of ultra-thin sections among observations. HRTEM studies of the mesoporous MCM-41 show that the pores have a hexagonal shape and also supports the mechanistic model proposed which involves a cooperative formation of a mesophase including the silicate species as well as the surfactant. 66 refs, 24 figs

  19. MULTIPULSE - high resolution and high power in one TDEM system

    Chen, Tianyou; Hodges, Greg; Miles, Philip

    2015-09-01

    An airborne time domain electromagnetic (TEM) system with high resolution and great depth of exploration is desired for geological mapping as well as for mineral exploration. The MULTIPULSE technology enables an airborne TEM system to transmit a high power pulse (a half-sine, for instance) and one or multiple low power pulse(s) (trapezoid or square) within a half-cycle. The high power pulse ensures good depth of exploration and the low power pulse allows a fast transmitter current turn off and earlier off-time measurement thus providing higher frequency signals, which allows higher near-surface resolution and better sensitivity to weak conductors. The power spectrum of the MULTIPULSE waveform comprising a half-sine and a trapezoid pulse clearly shows increased power in the higher frequency range (> ~2.3 kHz) compared to that of a single half-sine waveform. The addition of the low power trapezoid pulse extends the range of the sensitivity 10-fold towards the weak conductors, expanding the geological conductivity range of a system and increasing the scope of its applications. The MULTIPULSE technology can be applied to standard single-pulse airborne TEM systems on both helicopter and fixed-wing. We field tested the HELITEM MULTIPULSE system over a wire-loop in Iroquois Falls, demonstrating the different sensitivity of the high and low power pulses to the overburden and the wire-loop. We also tested both HELITEM and GEOTEM MULTIPULSE systems over a layered oil sand geologic setting in Fort McMurray, Alberta, Canada. The results show comparable shallow geologic resolution of the MULTIPULSE to that of the RESOLVE system while maintaining superior depth of exploration, confirming the increased geological conductivity range of a system employing MULTIPULSE compared to the standard single-pulse systems.

  20. High Resolution Sensor for Nuclear Waste Characterization

    Gamma ray spectrometers are an important tool in the characterization of radioactive waste. Important requirements for gamma ray spectrometers used in this application include good energy resolution, high detection efficiency, compact size, light weight, portability, and low power requirements. None of the available spectrometers satisfy all of these requirements. The goal of the Phase I research was to investigate lanthanum halide and related scintillators for nuclear waste clean-up. LaBr3:Ce remains a very promising scintillator with high light yield and fast response. CeBr3 is attractive because it is very similar to LaBr3:Ce in terms of scintillation properties and also has the advantage of much lower self-radioactivity, which may be important in some applications. CeBr3 also shows slightly higher light yield at higher temperatures than LaBr3 and may be easier to produce with high uniformity in large volume since it does not require any dopants. Among the mixed lanthanum halides, the light yield of LaBrxI3-x:Ce is lower and the difference in crystal structure of the binaries (LaBr3 and LaI3) makes it difficult to grow high quality crystals of the ternary as the iodine concentration is increased. On the other hand, LaBrxI3-x:Ce provides excellent performance. Its light output is high and it provides fast response. The crystal structures of the two binaries (LaBr3 and LaCl3) are very similar. Overall, its scintillation properties are very similar to those for LaBr3:Ce. While the gamma-ray stopping efficiency of LaBrxI3-x:Ce is lower than that for LaBr3:Ce (primarily because the density of LaCl3 is lower than that of LaBr3), it may be easier to grow large crystals of LaBrxI3-x:Ce than LaBr3:Ce since in some instances (for example, CdxZn1-xTe), the ternary compounds provide increased flexibility in the crystal lattice. Among the new dopants, Eu2+ and Pr3+, tried in LaBr3 host crystals, the Eu2+ doped samples exhibited low light output. This was mostly because a

  1. High resolution non-iterative aperture synthesis.

    Kraczek, Jeffrey R; McManamon, Paul F; Watson, Edward A

    2016-03-21

    The maximum resolution of a multiple-input multiple-output (MIMO) imaging system is determined by the size of the synthetic aperture. The synthetic aperture is determined by a coordinate shift using the relative positions of the illuminators and receive apertures. Previous methods have shown non-iterative phasing for multiple illuminators with a single receive aperture for intra-aperture synthesis. This work shows non-iterative phasing with both multiple illuminators and multiple receive apertures for inter-aperture synthesis. Simulated results show that piston, tip, and tilt can be calculated using inter-aperture phasing after intra-aperture phasing has been performed. Use of a fourth illuminator for increased resolution is shown. The modulation transfer function (MTF) is used to quantitatively judge increased resolution. PMID:27136816

  2. Cryogenic phased-array for high resolution magnetic resonance imaging (MRI); assessment of clinical and research applications

    Ip, Flora S.

    Magnetic Resonance (MR) imaging is one of the most powerful tools in diagnostic medicine for soft tissue imaging. Image acquisition techniques and hardware receivers are very important in achieving high contrast and high resolution MR images. An aim of this dissertation is to design single and multi-element room and cryogenic temperature arrays and make assessments of their signal-to-noise ratio (SNR) and SNR gain. In this dissertation, four sets of MR receiver coils are built. They are the receiver-only cryo-coils that are not commercially available. A tuning and matching circuit is attached to each coil. The tuning and matching circuits are simple; however, each device component has to operate at a high magnetic field and cryogenic temperature environment. Remote DC bias of the varactor controls the tuning and matching outside the scanner room. Active detuning of the resonator is done by two p-i-n junction (PIN) diodes. Cooling of the receiver is done by a customized liquid nitrogen cryostat. The first application is to build a 3-Tesla 2x1 horseshoe counter-rotating current (CRC) cryogenic array to image the tibia in a human body. With significant increase in SNR, the surface coil should deliver high contrast and resolution images that can show the trabecular bone and bone marrow structure. This structural image will be used to model the mechanical strength of the bone as well as bone density and chance of fracture. The planar CRC is a unique design of this surface array. The second application is to modify the coil design to 7-Tesla to study the growth of infant rhesus monkey eyes. Fast scan MR images of the infant monkey heads are taken for monitoring shapes of their eyeballs. The monkeys are induced with shortsightedness by eye lenses, and they are scanned periodically to get images of their eyeballs. The field-of-view (FOV) of these images is about five centimeters and the area of interest is two centimeters deep from the surface. Because of these reasons

  3. High Resolution Surface Science at Mars

    Bailey, Zachary J.; Tamppari, Leslie K.; Lock, Robert E.; Sturm, Erick J.

    2013-01-01

    The proposed mission would place a 2.4 m telescope in orbit around Mars with two focal plane instruments to obtain the highest resolution images and spectral maps of the surface to date (3-10x better than current). This investigation would make major contributions to all of the Mars Program Goals: life, climate, geology and preparation for human presence.

  4. High resolution with RCBC using classical optics

    A brief assessment of the possibility of a classical optical system for RCBC to give a resolution of better than 50 microns is presented. Reference is made to the tests made in RCBC during August 1981 and to the system installed on the 40 inch SLAC chamber. (orig.)

  5. High resolution x-ray microscope

    The authors present x-ray images of grid meshes and biological material obtained using a microspot x-ray tube with a multilayer optic and a 92-element parabolic compound refractive lens (CRL) made of a plastic containing only hydrogen and carbon. Images obtained using this apparatus are compared with those using an area source with a spherical lens and a spherical lens with multilayer condenser. The authors found the best image quality using the multilayer condenser with a parabolic lens, compared to images with a spherical lens and without the multilayer optics. The resolution was measured using a 155-element parabolic CRL and a multilayer condenser with the microspot tube. The experiment demonstrates about 1.1 μm resolution

  6. High resolution alpha particle spectrometry through collimation

    Alpha particle spectrometry with collimation is a useful method for identifying nuclear materials among various nuclides. A mesh type collimator reduces the low energy tail and broadened energy distribution by cutting off particles with a low incidence angle. The relation between the resolution and the counting efficiency can be investigated by changing a ratio of the mesh hole diameter and the collimator thickness. Through collimation, a target particle can be distinguished by a PIPS® detector under a mixture of various nuclides. - Highlights: • Alpha particle spectrometry with collimation a useful method for identifying nuclear materials among various radionuclides. • A collimator cut off alpha particles with low angle emitted from a source. • We confirm that that a collimator improves the resolution of alpha spectra through both simulation and experiments

  7. Intracellular membrane traffic at high resolution

    van Weering, Jan R.T.; Brown, Edward; Sharp, Thomas H.; Mantell, Judith; Cullen, Peter J.; Verkade, Paul

    2010-01-01

    Membrane traffic between organelles is essential for a multitude of processes that maintain cell homeostasis. Many steps in these tightly regulated trafficking pathways take place in microdomains on the membranes of organelles, which require analysis at nanometer resolution. Electron Microscopy (EM) can visualize these processes in detail and is mainly responsible for our current view of morphology on the subcellular level. This review discusses how EM can be applied to solve many questions o...

  8. High resolution laser mass spectrometry bioimaging.

    Murray, Kermit K; Seneviratne, Chinthaka A; Ghorai, Suman

    2016-07-15

    Mass spectrometry imaging (MSI) was introduced more than five decades ago with secondary ion mass spectrometry (SIMS) and a decade later with laser desorption/ionization (LDI) mass spectrometry (MS). Large biomolecule imaging by matrix-assisted laser desorption/ionization (MALDI) was developed in the 1990s and ambient laser MS a decade ago. Although SIMS has been capable of imaging with a moderate mass range at sub-micrometer lateral resolution from its inception, laser MS requires additional effort to achieve a lateral resolution of 10μm or below which is required to image at the size scale of single mammalian cells. This review covers untargeted large biomolecule MSI using lasers for desorption/ionization or laser desorption and post-ionization. These methods include laser microprobe (LDI) MSI, MALDI MSI, laser ambient and atmospheric pressure MSI, and near-field laser ablation MS. Novel approaches to improving lateral resolution are discussed, including oversampling, beam shaping, transmission geometry, reflective and through-hole objectives, microscope mode, and near-field optics. PMID:26972785

  9. High resolution neutron imaging for inertial confinement fusion experiments

    A high resolution neutron imaging system (NIS) is developed and tested on the OMEGA laser facility for inertial confinement fusion (ICF) experiments. This diagnostic uses a coded imaging technique with a high resolution neutron camera. Over the past few years, this detector was improved and neutron images can now be acquired on OMEGA with a 20 μm spatial resolution in the source plane and good signal to noise ratio with both a penumbral and an annular imaging technique. (authors)

  10. High resolution, high bandwidth global shutter CMOS area scan sensors

    Faramarzpour, Naser; Sonder, Matthias; Li, Binqiao

    2013-10-01

    Global shuttering, sometimes also known as electronic shuttering, enables the use of CMOS sensors in a vast range of applications. Teledyne DALSA Global shutter sensors are able to integrate light synchronously across millions of pixels with microsecond accuracy. Teledyne DALSA offers 5 transistor global shutter pixels in variety of resolutions, pitches and noise and full-well combinations. One of the recent generations of these pixels is implemented in 12 mega pixel area scan device at 6 um pitch and that images up to 70 frames per second with 58 dB dynamic range. These square pixels include microlens and optional color filters. These sensors also offer exposure control, anti-blooming and high dynamic range operation by introduction of a drain and a PPD reset gate to the pixel. The state of the art sense node design of Teledyne DALSA's 5T pixel offers exceptional shutter rejection ratio. The architecture is consistent with the requirements to use stitching to achieve very large area scan devices. Parallel or serial digital output is provided on these sensors using on-chip, column-wise analog to digital converters. Flexible ADC bit depth combined with windowing (adjustable region of interest, ROI) allows these sensors to run with variety of resolution/bandwidth combinations. The low power, state of the art LVDS I/O technology allows for overall power consumptions of less than 2W at full performance conditions.

  11. MR visualization of the inner ear structures: comparison of 1.5 Tesla and 3 Tesla images

    Aim of the Study: To compare high resolution MRI examinations of inner ear structures at 1.5 T and at 3 T. Method: Temporal bones were measured bilaterally in 3 healthy volunteers in a 1.5 T and in a 3 T MR-scanner using the respective one channel head coil (quadrature detection) of the manufacturer. The same steady-state gradient echo sequence (3D-CISS) was employed at a voxel size of 0.4x0.4x0.4mm3. The signal-to-noise ratio (SNR) was determined quantitatively. Results: An SNR of 8 could be achieved for the measurements at 3 T in 7:37 min. The SNR at 3 T was, on average, a factor of 1.34 higher than that at 1.5 T despite the fact that the excitation angle had to be drastically reduced (α = 42 instead of α = 70 at 1.5 T) due to the limit of the specific absorption rate (SAR). Discussion: The MR representation of the inner ear is clearly improved at 3 T. To obtain the same SNR at 1.5 T approximately the double measuring time would be required, connected with reduced patient comfort and an increased risk for a displacement of the head during the high resolution measurement. (orig.)

  12. Nanosecond microscopy with a high spectroscopic resolution

    Heinrich, C; Ritsch-Marte, M; Bernet, Stefan; Heinrich, Christoph; Ritsch-Marte, Monika

    2005-01-01

    We demonstrate coherent anti-Stokes Raman scattering (CARS) microscopy in a wide-field setup with nanosecond laser pulse excitation. In contrast to confocal setups, the image of a sample can be recorded with a single pair of excitation pulses. For this purpose the excitation geometry is specially designed in order to satisfy the phase matching condition over the whole sample area. The spectral, temporal and spatial sensitivity of the method is demonstrated by imaging test samples, i.e. oil vesicles in sunflower seeds, on a nanosecond timescale. The method provides snapshot imaging in 3 nanoseconds with a spectral resolution of 25 wavenumbers (cm$^{-1}$).

  13. High resolution IVEM tomography of biological specimens

    Sedat, J.W.; Agard, D.A. [Univ. of California, San Francisco, CA (United States)

    1997-02-01

    Electron tomography is a powerful tool for elucidating the three-dimensional architecture of large biological complexes and subcellular organelles. The introduction of intermediate voltage electron microscopes further extended the technique by providing the means to examine very large and non-symmetrical subcellular organelles, at resolutions beyond what would be possible using light microscopy. Recent studies using electron tomography on a variety of cellular organelles and assemblies such as centrosomes, kinetochores, and chromatin have clearly demonstrated the power of this technique for obtaining 3D structural information on non-symmetric cell components. When combined with biochemical and molecular observations, these 3D reconstructions have provided significant new insights into biological function.

  14. High-resolution X-ray diffraction studies of multilayers

    Christensen, Finn Erland; Hornstrup, Allan; Schnopper, H. W.

    1988-01-01

    High-resolution X-ray diffraction studies of the perfection of state-of-the-art multilayers are presented. Data were obtained using a triple-axis perfect-crystal X-ray diffractometer. Measurements reveal large-scale figure errors in the substrate. A high-resolution triple-axis set up is required...

  15. A broadband, high-resolution spatial heterodyne spectrometer

    Lawler, J E; Roesler, F L; Labby, Z [Department of Physics, University of Wisconsin, Madison, WI 53706 (United States); Harlander, J [Department of Physics, Astronomy, and Engineering Science, St. Cloud State University, St. Cloud, MN 56301 (United States)], E-mail: jelawler@wisc.edu

    2009-05-15

    Design and performance parameters of a broadband, high-resolution spatial heterodyne spectrometer (SHS) with a transmitting beamsplitter are described. This Mark 1 SHS achieves more than a factor of five in continuous wavenumber coverage with a resolving power in hundreds of thousands. Progress toward an all reflection, broadband, high-resolution Mark 2 SHS is reported.

  16. Assessment of MRI issues at 3-Tesla for metallic surgical implants: findings applied to 61 additional skin closure staples and vessel ligation clips

    Gill Amreeta

    2012-01-01

    Full Text Available Abstract Purpose Metallic skin closure staples and vessel ligation clips should be tested at 3-Tesla to characterize MRI issues in order to ensure patient safety. Therefore, metallic surgical implants were assessed at 3-Tesla for magnetic field interactions, MRI-related heating, and artifacts. Methods A skin closure staple (Visistat Skin Stapler, staple, Polytetrafluoroethylene, PTFE, coated 316L/316LVM stainless steel; Teleflex Medical, Durham, NC and a vessel ligation clip (Hemoclip Traditional, stainless steel; Teleflex Medical, Durham, NC that represented the largest metallic sizes made from materials with the highest magnetic susceptibilities (i.e., based on material information among 61 other surgical implants (52 metallic implants, 9 nonmetallic implants underwent evaluation for magnetic field interactions, MRI-related heating, and artifacts using standardized techniques. MRI-related heating was assessed by placing each implant in a gelled-saline-filled phantom with MRI performed using a transmit/receive RF body coil at an MR system reported, whole body averaged SAR of 2.9-W/kg for 15-min. Artifacts were characterized using T1-weighted, SE and GRE pulse sequences. Results Each surgical implant showed minor magnetic field interactions (20- and 27-degrees, which is acceptable from a safety consideration. Heating was not substantial (highest temperature change, ≤ 1.6°C. Artifacts may create issues if the area of interest is in the same area or close to the respective surgical implant. Conclusions The results demonstrated that it would be acceptable for patients with these metallic surgical implants to undergo MRI at 3-Tesla or less. Because of the materials and dimensions of the surgical implants that underwent testing, these findings pertain to 61 additional similar implants.

  17. High-Resolution Sonars: What Resolution Do We Need for Target Recognition?

    Pailhas Yan

    2010-01-01

    Full Text Available Target recognition in sonar imagery has long been an active research area in the maritime domain, especially in the mine-counter measure context. Recently it has received even more attention as new sensors with increased resolution have been developed; new threats to critical maritime assets and a new paradigm for target recognition based on autonomous platforms have emerged. With the recent introduction of Synthetic Aperture Sonar systems and high-frequency sonars, sonar resolution has dramatically increased and noise levels decreased. Sonar images are distance images but at high resolution they tend to appear visually as optical images. Traditionally algorithms have been developed specifically for imaging sonars because of their limited resolution and high noise levels. With high-resolution sonars, algorithms developed in the image processing field for natural images become applicable. However, the lack of large datasets has hampered the development of such algorithms. Here we present a fast and realistic sonar simulator enabling development and evaluation of such algorithms.We develop a classifier and then analyse its performances using our simulated synthetic sonar images. Finally, we discuss sensor resolution requirements to achieve effective classification of various targets and demonstrate that with high resolution sonars target highlight analysis is the key for target recognition.

  18. Waveform digitization for high resolution timing detectors with silicon photomultipliers

    The results of time resolution studies with silicon photomultipliers (SiPMs) read out with high bandwidth constant fraction discrimination electronics were presented earlier . Here we describe the application of fast waveform digitization readout based on the DRS4 chip , a switched capacitor array (SCA) produced by the Paul Scherrer Institute, to further our goal of developing high time resolution detectors based on SiPMs. The influence of the SiPM signal shape on the time resolution was investigated. Different algorithms to obtain the best time resolution are described, and test beam results are presented.

  19. The high spectral resolution (scanning) lidar (HSRL)

    Eloranta, E. [Univ. of Wisconsin, Madison, WI (United States)

    1995-09-01

    Lidars enable the spatial resolution of optical depth variation in clouds. The optical depth must be inverted from the backscatter signal, a process which is complicated by the fact that both molecular and aerosol backscatter signals are present. The HSRL has the advantage of allowing these two signals to be separated. It has a huge dynamic range, allowing optical depth retrieval for t = 0.01 to 3. Depolarization is used to determine the nature of hydrometeors present. Experiments show that water clouds must almost always be taken into account during cirrus observations. An exciting new development is the possibility of measuring effective radius via diffraction peak width and variable field-of-view measurements. 2 figs.

  20. High resolution time positron annihilation spectroscopy

    The ORTEC conventional positron lifetime spectrometer (PLS) with 12.9 cm3 plastic scintillation detector (BC-148), mounted with photo-multiplier (8850PMT), CFD discriminator (583) has been installed at the laboratory of physics of Center for Nuclear Techniques (Vietnam Atomic Energy Commission). The technical features of this system were investigated. The results show that the resolution time is better than 195 ps, and peak to background ratio in the spectrum measured with 10 μCi Na-22 is greater than 4000 of this conventional positron lifetime spectroscopy. The results of research using this spectrometer to study the porosity of materials are presented. The positronium formation in the medium of meso- and macro-pores, the correlation of macro pore size, porosity and positron lifetime characteristics will be discussed. The application of the PLS for the purpose of research and training are also proposed. (author)

  1. Achieving High Resolution Timer Events in Virtualized Environment

    Adamczyk, Blazej; Chydzinski, Andrzej

    2015-01-01

    Virtual Machine Monitors (VMM) have become popular in different application areas. Some applications may require to generate the timer events with high resolution and precision. This however may be challenging due to the complexity of VMMs. In this paper we focus on the timer functionality provided by five different VMMs—Xen, KVM, Qemu, VirtualBox and VMWare. Firstly, we evaluate resolutions and precisions of their timer events. Apparently, provided resolutions and precisions are far too low ...

  2. A high resolution global scale groundwater model

    de Graaf, Inge; Sutanudjaja, Edwin; van Beek, Rens; Bierkens, Marc

    2014-05-01

    As the world's largest accessible source of freshwater, groundwater plays a vital role in satisfying the basic needs of human society. It serves as a primary source of drinking water and supplies water for agricultural and industrial activities. During times of drought, groundwater storage provides a large natural buffer against water shortage and sustains flows to rivers and wetlands, supporting ecosystem habitats and biodiversity. Yet, the current generation of global scale hydrological models (GHMs) do not include a groundwater flow component, although it is a crucial part of the hydrological cycle. Thus, a realistic physical representation of the groundwater system that allows for the simulation of groundwater head dynamics and lateral flows is essential for GHMs that increasingly run at finer resolution. In this study we present a global groundwater model with a resolution of 5 arc-minutes (approximately 10 km at the equator) using MODFLOW (McDonald and Harbaugh, 1988). With this global groundwater model we eventually intend to simulate the changes in the groundwater system over time that result from variations in recharge and abstraction. Aquifer schematization and properties of this groundwater model were developed from available global lithological maps and datasets (Dürr et al., 2005; Gleeson et al., 2010; Hartmann and Moosdorf, 2013), combined with our estimate of aquifer thickness for sedimentary basins. We forced the groundwater model with the output from the global hydrological model PCR-GLOBWB (van Beek et al., 2011), specifically the net groundwater recharge and average surface water levels derived from routed channel discharge. For the parameterization, we relied entirely on available global datasets and did not calibrate the model so that it can equally be expanded to data poor environments. Based on our sensitivity analysis, in which we run the model with various hydrogeological parameter settings, we observed that most variance in groundwater

  3. Updating Maps Using High Resolution Satellite Imagery

    Alrajhi, Muhamad; Shahzad Janjua, Khurram; Afroz Khan, Mohammad; Alobeid, Abdalla

    2016-06-01

    Kingdom of Saudi Arabia is one of the most dynamic countries of the world. We have witnessed a very rapid urban development's which are altering Kingdom's landscape on daily basis. In recent years a substantial increase in urban populations is observed which results in the formation of large cities. Considering this fast paced growth, it has become necessary to monitor these changes, in consideration with challenges faced by aerial photography projects. It has been observed that data obtained through aerial photography has a lifecycle of 5-years because of delay caused by extreme weather conditions and dust storms which acts as hindrances or barriers during aerial imagery acquisition, which has increased the costs of aerial survey projects. All of these circumstances require that we must consider some alternatives that can provide us easy and better ways of image acquisition in short span of time for achieving reliable accuracy and cost effectiveness. The approach of this study is to conduct an extensive comparison between different resolutions of data sets which include: Orthophoto of (10 cm) GSD, Stereo images of (50 cm) GSD and Stereo images of (1 m) GSD, for map updating. Different approaches have been applied for digitizing buildings, roads, tracks, airport, roof level changes, filling stations, buildings under construction, property boundaries, mosques buildings and parking places.

  4. A high-resolution time-to-digital converter using a three-level resolution

    Dehghani, Asma; Saneei, Mohsen; Mahani, Ali

    2016-08-01

    In this article, a three-level resolution Vernier delay line time-to-digital converter (TDC) was proposed. The proposed TDC core was based on the pseudo-differential digital architecture that made it insensitive to nMOS and pMOS transistor mismatches. It also employed a Vernier delay line (VDL) in conjunction with an asynchronous read-out circuitry. The time interval resolution was equal to the difference of delay between buffers of upper and lower chains. Then, via the extra chain included in the lower delay line, resolution was controlled and power consumption was reduced. This method led to high resolution and low power consumption. The measurement results of TDC showed a resolution of 4.5 ps, 12-bit output dynamic range, and integral nonlinearity of 1.5 least significant bits. This TDC achieved the consumption of 68.43 µW from 1.1-V supply.

  5. Wide-field, high-resolution Fourier ptychographic microscopy

    Zheng, Guoan; Yang, Changhuei

    2014-01-01

    In this article, we report an imaging method, termed Fourier ptychographic microscopy (FPM), which iteratively stitches together a number of variably illuminated, low-resolution intensity images in Fourier space to produce a wide-field, high-resolution complex sample image. By adopting a wavefront correction strategy, the FPM method can also correct for aberrations and digitally extend a microscope's depth-of-focus beyond the physical limitations of its optics. As a demonstration, we built a microscope prototype with a resolution of 0.78 um, a field-of-view of ~120 mm2, and a resolution-invariant depth-of-focus of 0.3 mm (characterized at 632 nm). Gigapixel colour images of histology slides verify FPM's successful operation. The reported imaging procedure transforms the general challenge of high-throughput, high-resolution microscopy from one that is coupled to the physical limitations of the system's optics to one that is solvable through computation.

  6. A high resolution global scale groundwater model

    I. E. M. de Graaf

    2014-05-01

    Full Text Available Groundwater is the world's largest accessible source of fresh water. It plays a vital role in satisfying needs for drinking water, agriculture and industrial activities. During times of drought groundwater sustains baseflow to rivers and wetlands, thereby supporting ecosystems. Most global scale hydrological models (GHMs do not include a groundwater flow component, mainly due to lack of geohydrological data at the global scale. For the simulation of lateral flow and groundwater head dynamics a realistic physical representation of the groundwater system is needed, especially for GHMs that run at finer resolution. In this study we present a global scale groundwater model (run at 6' as dynamic steady state using MODFLOW to construct an equilibrium water table at its natural state as the result of long-term climatic forcing. The aquifer schematization and properties were based on available global datasets of lithology and transmissivities combined with estimated aquifer thickness of an upper unconfined aquifer. The model is forced with outputs from the land-surface model PCR-GLOBWB, specifically with net recharge and surface water levels. A sensitivity analysis, in which the model was run with various parameter settings, showed variation in saturated conductivity causes most of the groundwater level variations. Simulated groundwater heads were validated against reported piezometer observations. The validation showed that groundwater depths are reasonably well simulated for many regions of the world, especially for sediment basins (R2 = 0.95. The simulated regional scale groundwater patterns and flowpaths confirm the relevance of taking lateral groundwater flow into account in GHMs. Flowpaths show inter-basin groundwater flow that can be a significant part of a basins water budget and helps to sustain river baseflow, explicitly during times of droughts. Also important aquifer systems are recharged by inter-basin groundwater flows that positively

  7. High-Resolution Fluorometer for Mapping Microscale Phytoplankton Distributions

    Doubell, Mark J.; Seuront, Laurent; Seymour, Justin R.; Patten, Nicole L.; Mitchell, James G

    2006-01-01

    A new high-resolution, in situ profiling fluorometer maps fluorescence distributions with a spatial resolution of 0.5 to 1.5 mm to a depth of 70 m in the open ocean. We report centimeter-scale patterns for phytoplankton distributions associated with gradients exhibiting 10- to 30-fold changes in fluorescence in contrasting marine ecosystems.

  8. High-resolution fluorometer for mapping microscale phytoplankton distributions.

    Doubell, Mark J; Seuront, Laurent; Seymour, Justin R; Patten, Nicole L; Mitchell, James G

    2006-06-01

    A new high-resolution, in situ profiling fluorometer maps fluorescence distributions with a spatial resolution of 0.5 to 1.5 mm to a depth of 70 m in the open ocean. We report centimeter-scale patterns for phytoplankton distributions associated with gradients exhibiting 10- to 30-fold changes in fluorescence in contrasting marine ecosystems. PMID:16751572

  9. Reproducible high-resolution multispectral image acquisition in dermatology

    Duliu, Alexandru; Gardiazabal, José; Lasser, Tobias; Navab, Nassir

    2015-07-01

    Multispectral image acquisitions are increasingly popular in dermatology, due to their improved spectral resolution which enables better tissue discrimination. Most applications however focus on restricted regions of interest, imaging only small lesions. In this work we present and discuss an imaging framework for high-resolution multispectral imaging on large regions of interest.

  10. High resolution mid-infrared spectroscopy based on frequency upconversion

    Dam, Jeppe Seidelin; Hu, Qi; Tidemand-Lichtenberg, Peter; Pedersen, Christian

    2013-01-01

    We present high resolution upconversion of incoherent infrared radiation by means of sum-frequency mixing with a laser followed by simple CCD Si-camera detection. Noise associated with upconversion is, in strong contrast to room temperature direct mid-IR detection, extremely small, thus very faint...... signals can be analyzed. The obtainable frequency resolution is usually in the nm range where sub nm resolution is preferred in many applications, like gas spectroscopy. In this work we demonstrate how to obtain sub nm resolution when using upconversion. In the presented realization one object point is...

  11. Ultra-high resolution and high-brightness AMOLED

    Wacyk, Ihor; Ghosh, Amal; Prache, Olivier; Draper, Russ; Fellowes, Dave

    2012-06-01

    As part of its continuing effort to improve both the resolution and optical performance of AMOLED microdisplays, eMagin has recently developed an SXGA (1280×3×1024) microdisplay under a US Army RDECOM CERDEC NVESD contract that combines the world's smallest OLED pixel pitch with an ultra-high brightness green OLED emitter. This development is aimed at next-generation HMD systems with "see-through" and daylight imaging requirements. The OLED pixel array is built on a 0.18-micron CMOS backplane and contains over 4 million individually addressable pixels with a pixel pitch of 2.7 × 8.1 microns, resulting in an active area of 0.52 inches diagonal. Using both spatial and temporal enhancement, the display can provide over 10-bits of gray-level control for high dynamic range applications. The new pixel design also enables the future implementation of a full-color QSXGA (2560 × RGB × 2048) microdisplay in an active area of only 1.05 inch diagonal. A low-power serialized low-voltage-differential-signaling (LVDS) interface is integrated into the display for use as a remote video link for tethered systems. The new SXGA backplane has been combined with the high-brightness green OLED device developed by eMagin under an NVESD contract. This OLED device has produced an output brightness of more than 8000fL with all pixels on; lifetime measurements are currently underway and will presented at the meeting. This paper will describe the operational features and first optical and electrical test results of the new SXGA demonstrator microdisplay.

  12. Instrumental developments in high-resolution neutron measurements

    Instrumental developments in high-resolution neutron measurements are discussed from the viewpoint of time-of-flight experiments with broad spectrum neutron sources. Discussions are mainly restricted to the energy range above approx.= 100 keV, where most rapid progress has been made in recent years. The presentation begins with a few typical example of neutron investigations for which high-resolution measurements are important. Experimental conditions necessary to perform high-resolution measurements are briefly summarized. The relevant instrumental developments are then discussed in detail, and further improvements currently under active development are outlined. (orig.)

  13. Demonstration of ultra high resolution soft x-ray tomography

    Ultra high resolution three dimensional images of a microscopic test object were made with soft x-rays using a scanning transmission x-ray microscope. The test object consisted of two different patterns of gold bars on silicon nitride windows which were separated by ∼ 5μm. Depth resolution comparable to the transverse resolution was achieved by recording nine 2-D images of the object at angles between -50 to +55 degrees with respect to the beam axis. The projections were then combined tomographically to form a 3-D image using an algebraic reconstruction technique (ART) algorithm. We observed a transverse resolution of ∼1000 A. Artifacts in the reconstruction limited the overall depth resolution to ∼6000 A, however some features were clearly reconstructed with a depth resolution of ∼1000 A

  14. Demonstration of ultra high resolution soft x-ray tomography

    Haddad, W. S.; McNulty, I.; Trebes, J. E.; Anderson, E. H.; Yang, L.; Brase, J. M.

    1995-05-01

    Ultra high resolution three dimensional images of a microscopic test object were made with soft x-rays using a scanning transmission x-ray microscope. The test object consisted of two different patterns of gold bars on silicon nitride windows which were separated by ˜ 5μm. Depth resolution comparable to the transverse resolution was achieved by recording nine 2-D images of the object at angles between -50 to +55 degrees with respect to the beam axis. The projections were then combined tomographically to form a 3-D image using an algebraic reconstruction technique (ART) algorithm. We observed a transverse resolution of ˜1000 Å. Artifacts in the reconstruction limited the overall depth resolution to ˜6000 Å, however some features were clearly reconstructed with a depth resolution of ˜1000 Å.

  15. SUPER-RESOLUTION FROM A LOW- AND PARTIAL HIGH- RESOLUTION IMAGE PAIR

    Hidane, Moncef; Aujol, Jean-François; Berthoumieu, Yannick; Deledalle, Charles-Alban

    2014-01-01

    The classical super-resolution (SR) setting starts with a set of low-resolution (LR) images related by subpixel shifts and tries to reconstruct a single high-resolution (HR) image. In some cases, partial observations about the HR image are also available. Trying to complete the missing HR data without any reference to LR ones is an inpainting (or completion) problem. In this paper, we consider the problem of recov- ering a single HR image from a pair consisting of a complete LR and incomplete...

  16. High-resolution DEM Effects on Geophysical Flow Models

    Williams, M. R.; Bursik, M. I.; Stefanescu, R. E. R.; Patra, A. K.

    2014-12-01

    Geophysical mass flow models are numerical models that approximate pyroclastic flow events and can be used to assess the volcanic hazards certain areas may face. One such model, TITAN2D, approximates granular-flow physics based on a depth-averaged analytical model using inputs of basal and internal friction, material volume at a coordinate point, and a GIS in the form of a digital elevation model (DEM). The volume of modeled material propagates over the DEM in a way that is governed by the slope and curvature of the DEM surface and the basal and internal friction angles. Results from TITAN2D are highly dependent upon the inputs to the model. Here we focus on a single input: the DEM, which can vary in resolution. High resolution DEMs are advantageous in that they contain more surface details than lower-resolution models, presumably allowing modeled flows to propagate in a way more true to the real surface. However, very high resolution DEMs can create undesirable artifacts in the slope and curvature that corrupt flow calculations. With high-resolution DEMs becoming more widely available and preferable for use, determining the point at which high resolution data is less advantageous compared to lower resolution data becomes important. We find that in cases of high resolution, integer-valued DEMs, very high-resolution is detrimental to good model outputs when moderate-to-low (effect" from 1) a mathematically defined simulated elevation model, to demonstrate the terracing effects of integer valued data, and 2) a real-world DEM where terracing must be addressed. We discuss the effect on the flow model output and present possible solutions for rectification of the problem.

  17. Construction of a highly segmented high-resolution TOF system

    In the construction of a RHIC detector one of the most important efforts is to develop a powerful tracking and particle ID system. During FY90, the present group is focusing on the construction of a highly segmented particle ID device based on time-of-flight (TOF). In later years, the authors intend to develop a new tracking system to handle high-multiplicity density events. A typical event in a central Au + Au collisions at RHIC energies will have the following general characteristics: dMch/dΩ ∼ 300, Momentum of majority of particles < 1.6 GeV/c. In order to achieve particle ID for these particles, they concluded that a TOF wall with time resolution of σ < 100 ps with a segmentation of ∼ 4cm x 4cm at a 3 meter distance from the interaction point would do a reasonable job. A straightforward solution is to mount a scintillator directly on a phototube window. However, this configuration, which they call a flash-light type readout scheme, contains a serious problem in that Cerenkov light from the window of the phototube is superimposed on the scintillation light, thereby inducing a timing shift. The outstanding problem then, is to reduce or eliminate this Cerenkov light. One interesting method would be the construction of a new type of phototube which contains a mechanically separated photo-cathode. Before ordering the construction of this type of new phototube, however, they thought that it is important to measure quantitatively the contribution from Cerenkov light so that they clearly specify to the company the thickness of the material on which the photo-cathode should be coated. A Monte Carlo calculation was performed to determine the optimal separation of the photo-cathode from the phototube window

  18. Super high-resolution mesoscale weather prediction

    Saito, K.; Tsuyuki, T.; Seko, H.; Kimura, F.; Tokioka, T.; Kuroda, T.; Duc, L.; Ito, K.; Oizumi, T.; Chen, G.; Ito, J.; the Spire Field 3 Mesoscale Nwp Group

    2013-08-01

    A five-year research project of high performance regional numerical weather prediction is underway as one of the five research fields of the Strategic Programs for Innovative Research (SPIRE). The ultimate goal of the project is to demonstrate feasibility of precise prediction of severe weather phenomena using the K-computer. Three sub-themes of the project are shown with achievements at the present and developments in the near future.

  19. Super high-resolution mesoscale weather prediction

    A five-year research project of high performance regional numerical weather prediction is underway as one of the five research fields of the Strategic Programs for Innovative Research (SPIRE). The ultimate goal of the project is to demonstrate feasibility of precise prediction of severe weather phenomena using the K-computer. Three sub-themes of the project are shown with achievements at the present and developments in the near future

  20. High resolution multimodal clinical ophthalmic imaging system

    Mujat, Mircea; Ferguson, R. Daniel; Patel, Ankit H.; Iftimia, Nicusor; Lue, Niyom; Hammer, Daniel X.

    2010-01-01

    We developed a multimodal adaptive optics (AO) retinal imager which is the first to combine high performance AO-corrected scanning laser ophthalmoscopy (SLO) and swept source Fourier domain optical coherence tomography (SSOCT) imaging modes in a single compact clinical prototype platform. Such systems are becoming ever more essential to vision research and are expected to prove their clinical value for diagnosis of retinal diseases, including glaucoma, diabetic retinopathy (DR), age-related m...

  1. High resolution survey for topographic surveying

    In this decade, terrestrial laser scanner (TLS) is getting popular in many fields such as reconstruction, monitoring, surveying, as-built of facilities, archaeology, and topographic surveying. This is due the high speed in data collection which is about 50,000 to 1,000,000 three-dimensional (3D) points per second at high accuracy. The main advantage of 3D representation for the data is that it is more approximate to the real world. Therefore, the aim of this paper is to show the use of High-Definition Surveying (HDS), also known as 3D laser scanning for topographic survey. This research investigates the effectiveness of using terrestrial laser scanning system for topographic survey by carrying out field test in Universiti Teknologi Malaysia (UTM), Skudai, Johor. The 3D laser scanner used in this study is a Leica ScanStation C10. Data acquisition was carried out by applying the traversing method. In this study, the result for the topographic survey is under 1st class survey. At the completion of this study, a standard of procedure was proposed for topographic data acquisition using laser scanning systems. This proposed procedure serves as a guideline for users who wish to utilize laser scanning system in topographic survey fully

  2. MR visualization of the inner ear structures: comparison of 1.5 Tesla and 3 Tesla images

    Graf, H.; Schick, F. [Tuebingen Univ. (Germany). Sektion Experimentelle Radiologie; Claussen, C.D.; Seemann, M.D. [Tuebingen Univ. (Germany). Abt. fuer Radiologische Diagnostik

    2004-01-01

    Aim of the Study: To compare high resolution MRI examinations of inner ear structures at 1.5 T and at 3 T. Method: Temporal bones were measured bilaterally in 3 healthy volunteers in a 1.5 T and in a 3 T MR-scanner using the respective one channel head coil (quadrature detection) of the manufacturer. The same steady-state gradient echo sequence (3D-CISS) was employed at a voxel size of 0.4x0.4x0.4mm{sup 3}. The signal-to-noise ratio (SNR) was determined quantitatively. Results: An SNR of 8 could be achieved for the measurements at 3 T in 7:37 min. The SNR at 3 T was, on average, a factor of 1.34 higher than that at 1.5 T despite the fact that the excitation angle had to be drastically reduced ({alpha} = 42 instead of {alpha} = 70 at 1.5 T) due to the limit of the specific absorption rate (SAR). Discussion: The MR representation of the inner ear is clearly improved at 3 T. To obtain the same SNR at 1.5 T approximately the double measuring time would be required, connected with reduced patient comfort and an increased risk for a displacement of the head during the high resolution measurement. (orig.) [German] Ziel der Studie: Vergleich der hochaufloesenden MR-Bildgebung der Innenohrstrukturen bei 1,5 T und 3 T. Methode: Es wurden jeweils beide Felsenbeine von 3 freiwilligen, gehoergesunden Probanden an einem 1,5 T und einem 3 T MR-Tomographen mit einer einkanaligen Quadratur-Kopfspule des Herstellers gemessen. An beiden Tomographen wurde dieselbe Steady-State Gradientenecho-Sequenz (3D-CISS) bei einer Voxelgroesse von 0,4x0,4x0,4mm{sup 3} verwendet. Das erhaltene Signal-Rausch-Verhaeltnis (SNR) wurde quantitativ ermittelt. Ergebnis: Ein SNR von 8 wurde fuer die Messungen bei 3 T in 7:37 min erreicht. Der SNR-Wert bei 3 T uebertraf den Wert bei 1,5 T um durchschnittlich das 1,34-fache, obwohl aufgrund der Begrenzung in der spezifischen Absorptionsrate (SAR) nur mit deutlich reduziertem Anregewinkel ({alpha} = 42 anstatt {alpha} = 70 bei 1,5 T) gearbeitet werden konnte

  3. High resolution palaeoclimate records from Indonesia, Australia and Antarctica: The High Resolution Palaeoclimate Records Project

    The Environment and Physics Divisions at ANSTO has initiated a project to integrate the research efforts of palaeoecologists and isotope specialists working in the Southeast Asian, Australasian and Antractic regions. Entitled the High Resolution Palaeoclimate Records Project, its major goals are as follows: To improve the chronological control of key long palaeoecological records on a north-south transect from Indonesia, through Australia to Antarctica using U/Th and AMS radiocarbon dating techniques; To provide additional isotope information for these records; To correlate Palaeoclimatic change from different areas with the study region and contribute to the understanding of climatic change over the past 350,000 a; To contribute to the prediction of short and long term climate change scenarios using the principle that the past is the key to the present. The project will be a major contributor to the International Geosphere Biosphere Program (IGBP), and especially to the sub-programme Past Global Changes (PAGES) Pole-Equator-Pole II (PEP II) transect

  4. Some high resolution numerical schemes for hydrodynamic equation integration

    We present here some high resolution schemes for gas dynamical simulations in on space dimension. In case of Eulerian coordinates the schemes are formulated as a lagrangian step followed by a remap. We insist on numerical results

  5. Methodology of high-resolution photography for mural condition database

    Higuchi, R.; Suzuki, T.; Shibata, M.; Taniguchi, Y.

    2015-08-01

    Digital documentation is one of the most useful techniques to record the condition of cultural heritage. Recently, high-resolution images become increasingly useful because it is possible to show general views of mural paintings and also detailed mural conditions in a single image. As mural paintings are damaged by environmental stresses, it is necessary to record the details of painting condition on high-resolution base maps. Unfortunately, the cost of high-resolution photography and the difficulty of operating its instruments and software have commonly been an impediment for researchers and conservators. However, the recent development of graphic software makes its operation simpler and less expensive. In this paper, we suggest a new approach to make digital heritage inventories without special instruments, based on our recent our research project in Üzümlü church in Cappadocia, Turkey. This method enables us to achieve a high-resolution image database with low costs, short time, and limited human resources.

  6. High resolution difference schemes for compressible gas dynamics

    The advantages and disadvantages of four new high-resolution difference schemes, namely the von Neumann-Richtmyer, Godunovs, MUSCL and Glimms, for mathematically representing physical conditions in compressible gas flows are compared

  7. High Resolution Orthoimagery = Orthorectified Metro Areas: 2000 - Present

    U.S. Geological Survey, Department of the Interior — High resolution orthorectified images combine the image characteristics of an aerial photograph with the geometric qualities of a map. An orthoimage is a...

  8. A temperature-compensated high spatial resolution distributed strain sensor

    We propose and demonstrate a scheme which utilizes the temperature dependence of spontaneous Raman scattering to provide temperature compensation for a high spatial resolution Brillouin frequency-based strain sensor

  9. Very high resolution satellite data: New challenges in image analysis

    Sathe, P.V.; Muraleedharan, P.M.

    or other natural landscapes. Having very high resolution digital data over a landscape will however create new challenges in the field of atmospheric correction, ground registration, image processing and finally the image interpretation itself. Even...

  10. High Resolution CryoFESEM of Microbial Surfaces

    Erlandsen, Stanley; Lei, Ming; Martin-Lacave, Ines; Dunny, Gary; Wells, Carol

    2003-08-01

    The outer surfaces of three microorganisms, Giardia lamblia, Enterococcus faecalis, and Proteus mirabilis, were investigated by cryo-immobilization followed by sublimation of extracellular ice and cryocoating with either Pt alone or Pt plus carbon. Cryocoated samples were examined at [minus sign]125°C in either an in-lens field emission SEM or a below-the-lens field emission SEM. Cryocoating with Pt alone was sufficient for low magnification observation, but attempts to do high-resolution imaging resulted in radiolysis and cracking of the specimen surface. Double coating with Pt and carbon, in combination with high resolution backscatter electron detectors, enabled high-resolution imaging of the glycocalyx of bacteria, revealing a sponge-like network over the surface. High resolution examination of bacterial flagella also revealed a periodic substructure. Common artifacts included radiolysis leading to “cracking” of the surface, and insufficient deposition of Pt resulting in the absence of detectable surface topography.

  11. The Advanced X-ray Astrophysics Facility high resolution camera

    Murray, Stephen S.; Chappell, Jon H.

    1986-01-01

    The HRC (High Resolution Camera) is a photon counting instrument to be flown on the Advanced X-Ray Astrophysics Facility (AXAF). It is a large field of view, high angular resolution, detector for the X-ray telescope. The HRC consists of a CsI coated microchannel plate (MCP) acting as a soft X-ray photocathode, followed by a second MCP for high electronic gain. The MCPs are readout by a crossed grid of resistively coupled wires to provide high spatial resolution along with timing and pulse height data. The instrument will be used in two modes, as a direct imaging detector with a limiting sensitivity of 10 to the -15th ergs/sq cm sec in a 10 to the 5th second exposure, and as a readout for an objective transmission grating providing spectral resolution of several hundreds to thousands.

  12. High Resolution, Range/Range-Rate Imager Project

    National Aeronautics and Space Administration — Visidyne proposes to develop a design for a small, lightweight, high resolution, in x, y, and z Doppler imager to assist in the guidance, navigation and control...

  13. NOAA High-Resolution Sea Surface Temperature (SST) Analysis Products

    National Oceanic and Atmospheric Administration, Department of Commerce — This archive covers two high resolution sea surface temperature (SST) analysis products developed using an optimum interpolation (OI) technique. The analyses have a...

  14. High resolution simulation of the South Asian monsoon using a variable resolution global climate model

    P Sabin, T.; Krishnan, R.; Ghattas, Josefine; Denvil, Sebastien; Dufresne, Jean-Louis; Hourdin, Frederic; Pascal, Terray

    2013-07-01

    This study examines the feasibility of using a variable resolution global general circulation model (GCM), with telescopic zooming and enhanced resolution (~35 km) over South Asia, to better understand regional aspects of the South Asian monsoon rainfall distribution and the interactions between monsoon circulation and precipitation. For this purpose, two sets of ten member realizations are produced with and without zooming using the LMDZ (Laboratoire Meteorologie Dynamique and Z stands for zoom) GCM. The simulations without zoom correspond to a uniform 1° × 1° grid with the same total number of grid points as in the zoom version. So the grid of the zoomed simulations is finer inside the region of interest but coarser outside. The use of these finer and coarser resolution ensemble members allows us to examine the impact of resolution on the overall quality of the simulated regional monsoon fields. It is found that the monsoon simulation with high-resolution zooming greatly improves the representation of the southwesterly monsoon flow and the heavy precipitation along the narrow orography of the Western Ghats, the northeastern mountain slopes and northern Bay of Bengal (BOB). A realistic Monsoon Trough (MT) is also noticed in the zoomed simulation, together with remarkable improvements in representing the associated precipitation and circulation features, as well as the large-scale organization of meso-scale convective systems over the MT region. Additionally, a more reasonable simulation of the monsoon synoptic disturbances (lows and disturbances) along the MT is noted in the high-resolution zoomed simulation. On the other hand, the no-zoom version has limitations in capturing the depressions and their movement, so that the MT zone is relatively dry in this case. Overall, the results from this work demonstrate the usefulness of the high-resolution variable resolution LMDZ model in realistically capturing the interactions among the monsoon large-scale dynamics

  15. Non-Parametric High-Resolution SAR Imaging

    Glentis, George-Othan; Zhao, Kexin; Jakobsson, Andreas; Li, Jian

    2013-01-01

    The development of high-resolution two-dimensional spectral estimation techniques is of notable interest in synthetic aperture radar (SAR) imaging. Typically, data-independent techniques are exploited to form the SAR images, although such approaches will suffer from limited resolution and high sidelobe levels. Recent work on data-adaptive approaches have shown that both the iterative adaptive approach (IAA) and the sparse learning via iterative minimization (SLIM) algorithm offer ...

  16. Parametric analysis of airland combat model in high resolution.

    Lee, Jae Yeong

    1988-01-01

    Approved for public release; distribution is unlimited A high resolution deterministic combat model is analyzed in this thesis. Actual Republic of Korea (ROK) terrain data is employed in the model. The goal of the thesis is to analyze key parameters which are routinely used in high resolution combat models. These parameters are attrition rate coefTicients, force size, courses of action, and the Weiss parameter (in the equation for Helmbold type combat). The model's scenario divides the bat...

  17. A high-resolution vacuum ultraviolet spectrometer for plasma spectroscopy

    Meijer, F. G.

    1999-01-01

    A high-resolution spectrometer for the wavelength range 40-200 nm was adapted to a high-speed photo-electric detection system. A wavelength range of 3 nm can be measured up to every 0.2 ms with a resolution of 0.0012 nm and a wavelength accuracy of 0.0001 nm. The system is used for plasma spectrosco

  18. High resolution computed tomography for peripheral facial nerve paralysis

    High resolution computer tomographic examinations of the petrous bones were performed on 19 patients with confirmed peripheral facial nerve paralysis. High resolution CT provides accurate information regarding the extent, and usually regarding the type, of pathological process; this can be accurately localised with a view to possible surgical treatments. The examination also differentiates this from idiopathic paresis, which showed no radiological changes. Destruction of the petrous bone, without facial nerve symptoms, makes early suitable treatment mandatory. (orig.)

  19. High resolution spectrum estimation for digital tracking array

    Yeo, Kwang Hui

    2009-01-01

    To design a high resolution spectrum estimation module as part of a digital tracking array system, the theory and mathematical formulations of several high resolution spectrum estimation methods are presented. In the implementation of a spectrum estimation system, the received signal is first down-converted to baseband frequency using single channel or in-phase (I) and quad phase (Q) channel down-converter before it is digitized using an analog-to-digital (ADC) converter. Three distinct fre...

  20. High resolution computed tomography for peripheral facial nerve paralysis

    Koester, O.; Straehler-Pohl, H.J.

    1987-01-01

    High resolution computer tomographic examinations of the petrous bones were performed on 19 patients with confirmed peripheral facial nerve paralysis. High resolution CT provides accurate information regarding the extent, and usually regarding the type, of pathological process; this can be accurately localised with a view to possible surgical treatments. The examination also differentiates this from idiopathic paresis, which showed no radiological changes. Destruction of the petrous bone, without facial nerve symptoms, makes early suitable treatment mandatory.

  1. Dynamics of High-Resolution Networks

    Sekara, Vedran

    NETWORKS are everywhere. From the smallest confines of the cells within our bodies to the webs of social relations across the globe. Networks are not static, they constantly change, adapt, and evolve to suit new conditions. In order to understand the fundamental laws that govern networks we need...... new, highly detailed maps that uncover the interactions of all constituents, accurately and in a temporal manner. One of the hardest networks to understand, but also one of the most interesting ones, is the human social network. How do humans interact, form friendships, and spread information? And how...... are we all affected by an ever changing network structure? Answering these questions will enrich our understanding of ourselves, our organizations, and our societies. Yet, mapping the dynamics of social networks has traditionally been an arduous undertaking. Today, however, it is possible to use...

  2. Liquid Scintillation High Resolution Spectral Analysis

    Grau Carles, A.; Grau Malonda, A.

    2010-08-06

    The CIEMAT/NIST and the TDCR methods in liquid scintillation counting are based on the determination of the efficiency for total counting. This paper tries to expand these methods analysing the pulse-height spectrum of radionuclides. To reach this objective we have to generalize the equations used in the model and to analyse the influence of ionization and chemical quench in both spectra and counting efficiency. We present equations to study the influence of different photomultipliers response in systems with one, two or three photomultipliers. We study the effect of the electronic noise discriminator level in both spectra and counting efficiency. The described method permits one to study problems that up to now was not possible to approach, such as the high uncertainty in the standardization of pure beta-ray emitter with low energy when we apply the TDCR method, or the discrepancies in the standardization of some electron capture radionuclides, when the CIEMAT/NIST method is applied. (Author) 107 refs.

  3. Liquid Scintillation High Resolution Spectral Analysis

    The CIEMAT/NIST and the TDCR methods in liquid scintillation counting are based on the determination of the efficiency for total counting. This paper tries to expand these methods analysing the pulse-height spectrum of radionuclides. To reach this objective we have to generalize the equations used in the model and to analyse the influence of ionization and chemical quench in both spectra and counting efficiency. We present equations to study the influence of different photomultipliers response in systems with one, two or three photomultipliers. We study the effect of the electronic noise discriminator level in both spectra and counting efficiency. The described method permits one to study problems that up to now was not possible to approach, such as the high uncertainty in the standardization of pure beta-ray emitter with low energy when we apply the TDCR method, or the discrepancies in the standardization of some electron capture radionuclides, when the CIEMAT/NIST method is applied. (Author) 107 refs.

  4. High resolution single particle refinement in EMAN2.1.

    Bell, James M; Chen, Muyuan; Baldwin, Philip R; Ludtke, Steven J

    2016-05-01

    EMAN2.1 is a complete image processing suite for quantitative analysis of grayscale images, with a primary focus on transmission electron microscopy, with complete workflows for performing high resolution single particle reconstruction, 2-D and 3-D heterogeneity analysis, random conical tilt reconstruction and subtomogram averaging, among other tasks. In this manuscript we provide the first detailed description of the high resolution single particle analysis pipeline and the philosophy behind its approach to the reconstruction problem. High resolution refinement is a fully automated process, and involves an advanced set of heuristics to select optimal algorithms for each specific refinement task. A gold standard FSC is produced automatically as part of refinement, providing a robust resolution estimate for the final map, and this is used to optimally filter the final CTF phase and amplitude corrected structure. Additional methods are in-place to reduce model bias during refinement, and to permit cross-validation using other computational methods. PMID:26931650

  5. Climatologies at high resolution for the Earth land surface areas

    Karger, Dirk Nikolaus; Böhner, Jürgen; Kawohl, Tobias; Kreft, Holger; Soria-Auza, Rodrigo Wilber; Zimmermann, Niklaus; Linder, H Peter; Kessler, Michael

    2016-01-01

    High resolution information of climatic conditions is essential to many application in environmental sciences. Here we present the CHELSA algorithm to downscale temperature and precipitation estimates from the European Centre for Medium-Range Weather Forecast (ECMWF) climatic reanalysis interim (ERA-Interim) to a high resolution of 30 arc sec. The algorithm for temperature is based on a statistical downscaling of atmospheric temperature from the ERA-Interim climatic reanalysis. The precipitation algorithm incorporates orographic predictors such as wind fields, valley exposition, and boundary layer height, and a bias correction using Global Precipitation Climatology Center (GPCC) gridded and Global Historical Climate Network (GHCN) station data. The resulting data consist of a monthly temperature and precipitation climatology for the years 1979-2013. We present a comparison of data derived from the CHELSA algorithm with two other high resolution gridded products with overlapping temporal resolution (Tropical R...

  6. A Very High Spatial Resolution Detector for Small Animal PET

    Positron Emission Tomography (PET) is an in vivo analog of autoradiography and has the potential to become a powerful new tool in imaging biological processes in small laboratory animals. PET imaging of small animals can provide unique information that can help in advancement of human disease models as well as drug development. Clinical PET scanners used for human imaging are bulky, expensive and do not have adequate spatial resolution for small animal studies. Hence, dedicated, low cost instruments are required for conducting small animal studies with higher spatial resolution than what is currently achieved with clinical as well as dedicated small animal PET scanners. The goal of the proposed project is to investigate a new all solid-state detector design for small animal PET imaging. Exceptionally high spatial resolution, good timing resolution, and excellent energy resolution are expected from the proposed detector design. The Phase I project was aimed at demonstrating the feasibility of producing high performance solid-state detectors that provide high sensitivity, spatial resolution, and timing characteristics. Energy resolution characteristics of the new detector were also investigated. The goal of the Phase II project is to advance the promising solid-state detector technology for small animal PET and determine its full potential. Detectors modules will be built and characterized and finally, a bench-top small animal PET system will be assembled and evaluated

  7. High resolution surface plasmon microscopy for cell imaging

    Argoul, F.; Monier, K.; Roland, T.; Elezgaray, J.; Berguiga, L.

    2010-04-01

    We introduce a new non-labeling high resolution microscopy method for cellular imaging. This method called SSPM (Scanning Surface Plasmon Microscopy) pushes down the resolution limit of surface plasmon resonance imaging (SPRi) to sub-micronic scales. High resolution SPRi is obtained by the surface plasmon lauching with a high numerical aperture objective lens. The advantages of SPPM compared to other high resolution SPRi's rely on three aspects; (i) the interferometric detection of the back reflected light after plasmon excitation, (ii) the twodimensional scanning of the sample for image reconstruction, (iii) the radial polarization of light, enhancing both resolution and sensitivity. This microscope can afford a lateral resolution of - 150 nm in liquid environment and - 200 nm in air. We present in this paper images of IMR90 fibroblasts obtained with SSPM in dried environment. Internal compartments such as nucleus, nucleolus, mitochondria, cellular and nuclear membrane can be recognized without labelling. We propose an interpretation of the ability of SSPM to reveal high index contrast zones by a local decomposition of the V (Z) function describing the response of the SSPM.

  8. High resolution temperature measurement technique for measuring marine heat flow

    QIN; YangYang; YANG; XiaoQiu; WU; BaoZhen; SUN; ZhaoHua; SHI; XiaoBin

    2013-01-01

    High resolution temperature measurement technique is one of the key techniques for measuring marine heat flow. Basing on Pt1000 platinum resistance which has the characteristics of high accuracy and good stability, we designed a bridge reversal excitation circuit for high resolution temperature measurement. And the deep ocean floor in-situ test results show that: (1) temperature deviation and peak-to-peak resolution of the first version circuit board (V1) are 1.960-1.990 mK and 0.980-0.995 m Kat 1.2-2.7°C, respectively; and temperature deviation and peak-to-peak resolution of the second circuit board (V2) are 2.260mK and 1.130 mK at 1.2-1.3°C, respectively; (2) During the 2012NSFC-IndOcean cruise, seafloor geothermal gradient at Ind2012HF03,-07 and-12 stations (water depth ranges from 3841 to 4541 m) were successfully measured, the values are 59.1,75.1 and 71.6°C/km, respectively. And the measurement errors of geothermal gradient at these three stations are less than 3.0% in terms of the peak-to-peak resolution. These indicate that the high resolution temperature measurement technique based on Pt1000 platinum resistance in this paper can be applied to marine heat flow measurement to obtain high precision geothermal parameters.

  9. Developments in magnets for the high resolution RCNP spectrograph

    A summary is given for the developments of magnets employed in the high resolution spectrometer now in operation at RCNP. Special care was taken to obtain high uniformities in the magnetic field distributions. A new method for constructing a magnet with a high field uniformity as well as a good reproducibility at a reasonable cost is described. (author)

  10. High-resolution spectroscopy of gases for industrial applications

    Fateev, Alexander; Clausen, Sønnik

    High-resolution spectroscopy of gases is a powerful technique which has various fundamental and practical applications: in situ simultaneous measurements of gas temperature and gas composition, radiative transfer modeling, validation of existing and developing of new databases and etc. Existing...... analysis of complex experimental data and further development of the databases. High-temperature gas cell facilities available at DTU Chemical Engineering are presented and described. The gas cells and high-resolution spectrometers allow us to perform high-quality reference measurements of gases relevant...

  11. Accelerated High-Resolution Photoacoustic Tomography via Compressed Sensing

    Arridge, Simon; Betcke, Marta; Cox, Ben; Huynh, Nam; Lucka, Felix; Ogunlade, Olumide; Zhang, Edward

    2016-01-01

    Current 3D photoacoustic tomography (PAT) systems offer either high image quality or high frame rates but are not able to deliver high spatial and temporal resolution simultaneously, which limits their ability to image dynamic processes in living tissue. A particular example is the planar Fabry-Perot (FP) scanner, which yields high-resolution images but takes several minutes to sequentially map the photoacoustic field on the sensor plane, point-by-point. However, as the spatio-temporal complexity of many absorbing tissue structures is rather low, the data recorded in such a conventional, regularly sampled fashion is often highly redundant. We demonstrate that combining variational image reconstruction methods using spatial sparsity constraints with the development of novel PAT acquisition systems capable of sub-sampling the acoustic wave field can dramatically increase the acquisition speed while maintaining a good spatial resolution: First, we describe and model two general spatial sub-sampling schemes. Then...

  12. High energy resolution requirements for a spectrometer at GANIL

    Factors which must be considered in the design of a high energy resolution magnetic spectrometer for the GANIL cyclotron are examined. It is shown that by optimising target conditions an energy resolution of approximately 2 x 10-4 is possible. To achieve such a resolution broadening effects due to the energy spread of the incident beam, the kinematic effects in the angular aperture of the spectrometer and the kinematic effects induced by the beam angular divergence must be avoided. General features of a possible energy loss spectrometer at GANIL are given. (UK)

  13. Performance of a High Resolution Cavity Beam Position Monitor System

    Walston, S; Boogert, S; Chung, C; Fitsos, P; Frisch, J; Gronberg, J; Hayano, H; Honda, Y; Kolomensky, Y; Lyapin, A; Malton, S; May, J; McCormick, D; Meller, R; Miller, D; Orimoto, T; Ross, M; Slater, M; Smith, S; Smith, T; Terunuma, N; Thomson, M; Urakawa, J; Vogel, V; Ward, D; White, G

    2006-12-18

    It has been estimated that an RF cavity Beam Position Monitor (BPM) could provide a position measurement resolution of less than one nanometer. We have developed a high resolution cavity BPM and associated electronics. A triplet comprised of these BPMs was installed in the extraction line of the Accelerator Test Facility (ATF) at the High Energy Accelerator Research Organization (KEK) for testing with its ultra-low emittance beam. The three BPMs were each rigidly mounted inside an alignment frame on six variable-length struts which could be used to move the BPMs in position and angle. We have developed novel methods for extracting the position and tilt information from the BPM signals including a robust calibration algorithm which is immune to beam jitter. To date, we have demonstrated a position resolution of 15.6 nm and a tilt resolution of 2.1 {micro}rad over a dynamic range of approximately {+-} 20 {micro}m.

  14. Performance of a High Resolution Cavity Beam Position Monitor System

    Walston, Sean; Boogert, Stewart; Chung, Carl; Fitsos, Joe; Frisch, Joe; Gronberg, Jeff; Hayano, Hitoshi; Honda, Yosuke; Kolomensky, Yury; Lyapin, Alexey; Malton, Stephen; May, Justin; McCormick, Douglas; Meller, Robert; Miller, David John; Orimoto, Toyoko; Ross, Marc; Slater, Mark; Smith, Steve; Smith, Tonee; Terunuma, Nobuhiro; /Fermilab /UC,

    2007-06-08

    It has been estimated that an RF cavity Beam Position Monitor (BPM) could provide a position measurement resolution of less than one nanometer. We have developed a high resolution cavity BPM and associated electronics. A triplet comprised of these BPMs was installed in the extraction line of the Accelerator Test Facility (ATF) at the High Energy Accelerator Research Organization (KEK) for testing with its ultra-low emittance beam. The three BPMs were each rigidly mounted inside an alignment frame on six variable-length struts which could be used to move the BPMs in position and angle. We have developed novel methods for extracting the position and tilt information from the BPM signals including a robust calibration algorithm which is immune to beam jitter. To date, we have demonstrated a position resolution of 15.6 nm and a tilt resolution of 2.1 {mu}rad over a dynamic range of approximately {+-} 20 {mu}m.

  15. High Resolution Muon Computed Tomography at Neutrino Beam Facilities

    Suerfu, Burkhant

    2015-01-01

    X-ray computed tomography (CT) has an indispensable role in constructing 3D images of objects made from light materials. However, limited by absorption coefficients, X-rays cannot deeply penetrate materials such as copper and lead. Here we show via simulation that muon beams can provide high resolution tomographic images of dense objects and of structures within the interior of dense objects. The effects of resolution broadening from multiple scattering diminish with increasing muon momentum. As the momentum of the muon increases, the contrast of the image goes down and therefore requires higher resolution in the muon spectrometer to resolve the image. The variance of the measured muon momentum reaches a minimum and then increases with increasing muon momentum. The impact of the increase in variance is to require a higher integrated muon flux to reduce fluctuations. The flux requirements and level of contrast needed for high resolution muon computed tomography are well matched to the muons produced in the pio...

  16. High resolution nitrogen dioxide observations: retrieval, evaluation, and interpretation

    Lamsal, L. N.; Janz, S. J.; Krotkov, N. A.; Pickering, K. E.; Kowalewski, M. G.; Loughner, C.; Spurr, R. J. D.; Crawford, J. H.

    2015-12-01

    The Airborne Compact Atmospheric Mapper (ACAM) deployed during the DISCOVER-AQ Maryland field campaign made hyperspectral remote sensing measurements in the 304-910 nm range allowing observations of several tropospheric pollutants including nitrogen dioxide (NO2) at an unprecedented spatial resolution of 1.5x0.75 km2. We apply the DOAS method, include high resolution information for surface reflectivity and vertical distributions of NO2 and aerosols, and account for temporal variation in atmospheric NO2 to retrieve lower tropospheric NO2 column. We compare NO2 from ACAM with observations from in-situ aircraft, ground-based PANDORA, and space-based OMI, and NO2 simulation from air quality models. The high resolution ACAM measurements offer not only new insights into our understanding of atmospheric composition and chemistry through observation of sub-sampling variability in typical satellite and model resolutions, but also opportunities for algorithm improvements for upcoming geostationary air quality missions.

  17. High-resolution EEG: applications in medicine and cognitive science

    Nunez, P. L.

    1993-08-01

    Electroencephalography (EEG) is the primary means of studying neocortical dynamic function in the millisecond time scales at which information is processed. However, the information content of conventional EEG is severely limited by its poor spatial resolution (approximately 6 cm). With high resolution EEG, spatial resolution can be improved by a factor of three or more (approximately 2 cm). Two categories of methods have been used to obtain high resolution EEG: surface Laplacian (i.e., 'current source density') and cortical imaging (i.e., 'spatial deconvolution'). While these methods have somewhat different theoretical bases, each essentially involves an estimate of cortical surface potential. Computer simulations involving widely distributed sources are used to demonstrate the apparent accuracy of various approaches.

  18. High Resolution Local Structure-Constrained Image Upsampling.

    Zhao, Yang; Wang, Ronggang; Wang, Wenmin; Gao, Wen

    2015-11-01

    With the development of ultra-high-resolution display devices, the visual perception of fine texture details is becoming more and more important. A method of high-quality image upsampling with a low cost is greatly needed. In this paper, we propose a fast and efficient image upsampling method that makes use of high-resolution local structure constraints. The average local difference is used to divide a bicubic-interpolated image into a sharp edge area and a texture area, and these two areas are reconstructed separately with specific constraints. For reconstruction of the sharp edge area, a high-resolution gradient map is estimated as an extra constraint for the recovery of sharp and natural edges; for the reconstruction of the texture area, a high-resolution local texture structure map is estimated as an extra constraint to recover fine texture details. These two reconstructed areas are then combined to obtain the final high-resolution image. The experimental results demonstrated that the proposed method recovered finer pixel-level texture details and obtained top-level objective performance with a low time cost compared with state-of-the-art methods. PMID:26186777

  19. Land Cover Semantic Annotation Derived from High Resolution SAR Images

    Dumitru, Corneliu Octavian; Schwarz, Gottfried; Datcu, Mihai

    2016-01-01

    Users of remote sensing images analyzing land cover characteristics are very much interested in classification schemes that define a consistent set of target categories. Up to now, a number of established classification schemes are mainly being used by interpreters of medium-resolution optical satellite image focusing on large-scale land cover. In contrast, we concentrate in this publication on the definition of a new classification scheme for high-resolution synthetic aperture radar (S...

  20. Impact of image-space resolution modeling for studies with the high-resolution research tomograph

    Brain PET in small structures is challenged by low resolution inducing bias in the activity measurements. Improved spatial resolution may be obtained by using dedicated tomographs and more comprehensive modeling of the acquisition system during reconstruction. In this study, we assess the impact of resolution modeling (RM) during reconstruction on image quality and on the estimates of biologic parameters in a clinical study performed on a high-resolution research tomograph. Methods: An accelerated list-mode ordinary Poisson ordered-subset expectation maximization (OP-OSEM) algorithm, including sinogram-based corrections and an experimental stationary model of resolution, has been designed. Experimental phantom studies are used to assess contrast and noise characteristics of the reconstructed images. The binding potential of a selective tracer of the dopamine transporter is also assessed in anatomic volumes of interest in a 5-patient study. Results: In the phantom experiment, a slower convergence and a higher contrast recovery are observed for RM-OP-OSEM than for OP-OSEM for the same level of statistical noise. RM-OP-OSEM yields contrast recovery levels that could not be reached without RM as well as better visual recovery of the smallest spheres and better delineation of the structures in the reconstructed images. Statistical noise has lower variance at the voxel level with RM than without at matched resolution. In a uniform activity region, RM induces higher positive and lower negative correlations with neighboring voxels, leading to lower spatial variance. Clinical images reconstructed with RM demonstrate better delineation of cortical and subcortical structures in both time-averaged and parametric images. The binding potential in the striatum is also increased, a result similar to the one observed in the phantom study. Conclusion: In high-resolution PET, RM during reconstruction improves quantitative accuracy by reducing the partial-volume effects. (authors)

  1. Isotope specific resolution recovery image reconstruction in high resolution PET imaging

    Kotasidis, Fotis A. [Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211 Geneva, Switzerland and Wolfson Molecular Imaging Centre, MAHSC, University of Manchester, M20 3LJ, Manchester (United Kingdom); Angelis, Georgios I. [Faculty of Health Sciences, Brain and Mind Research Institute, University of Sydney, NSW 2006, Sydney (Australia); Anton-Rodriguez, Jose; Matthews, Julian C. [Wolfson Molecular Imaging Centre, MAHSC, University of Manchester, Manchester M20 3LJ (United Kingdom); Reader, Andrew J. [Montreal Neurological Institute, McGill University, Montreal QC H3A 2B4, Canada and Department of Biomedical Engineering, Division of Imaging Sciences and Biomedical Engineering, King' s College London, St. Thomas’ Hospital, London SE1 7EH (United Kingdom); Zaidi, Habib [Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211 Geneva (Switzerland); Geneva Neuroscience Centre, Geneva University, CH-1205 Geneva (Switzerland); Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, PO Box 30 001, Groningen 9700 RB (Netherlands)

    2014-05-15

    Purpose: Measuring and incorporating a scanner-specific point spread function (PSF) within image reconstruction has been shown to improve spatial resolution in PET. However, due to the short half-life of clinically used isotopes, other long-lived isotopes not used in clinical practice are used to perform the PSF measurements. As such, non-optimal PSF models that do not correspond to those needed for the data to be reconstructed are used within resolution modeling (RM) image reconstruction, usually underestimating the true PSF owing to the difference in positron range. In high resolution brain and preclinical imaging, this effect is of particular importance since the PSFs become more positron range limited and isotope-specific PSFs can help maximize the performance benefit from using resolution recovery image reconstruction algorithms. Methods: In this work, the authors used a printing technique to simultaneously measure multiple point sources on the High Resolution Research Tomograph (HRRT), and the authors demonstrated the feasibility of deriving isotope-dependent system matrices from fluorine-18 and carbon-11 point sources. Furthermore, the authors evaluated the impact of incorporating them within RM image reconstruction, using carbon-11 phantom and clinical datasets on the HRRT. Results: The results obtained using these two isotopes illustrate that even small differences in positron range can result in different PSF maps, leading to further improvements in contrast recovery when used in image reconstruction. The difference is more pronounced in the centre of the field-of-view where the full width at half maximum (FWHM) from the positron range has a larger contribution to the overall FWHM compared to the edge where the parallax error dominates the overall FWHM. Conclusions: Based on the proposed methodology, measured isotope-specific and spatially variant PSFs can be reliably derived and used for improved spatial resolution and variance performance in resolution

  2. Adaptive Resolution Simulations with Self-Adjusting High-Resolution Regions.

    Kreis, Karsten; Potestio, Raffaello; Kremer, Kurt; Fogarty, Aoife C

    2016-08-01

    In adaptive resolution simulations, different regions of a simulation box are modeled with different levels of detail. Particles change their resolution on-the-fly when traveling from one subregion to the other. This method is particularly useful for studying multiscale systems in which effects on a broad range of length and time scales play a role. Until now, the geometry of the high-resolution region has been limited to simple geometries of spherical, cuboid, or cylindrical form, whose shape does not change during the simulation. However, many phenomena involve changes in size and shape of system components, for example, protein folding, polymer collapse, nucleation, and crystallization. In this work, we develop a scheme that uses a series of overlapping spheres to allow for an arbitrary division of space into domains of different levels of resolution. Furthermore, the geometry is automatically adjusted on-the-fly during the simulation according to changes in size and shape of, for example, a solvated macromolecule within the high-resolution region. The proposed approach is validated on liquid water. We then simulate the folding of an atomistically detailed polypeptide solvated in a shell of atomistic water that changes shape as the peptide conformation changes. We demonstrate that the peptide folding process is unperturbed by the use of our methodology. PMID:27384753

  3. Development of ultra-high resolution observation device

    The charge exchange foil causes a pinhole and transformation by heat and radiation injury generated during the beam irradiation. 10μm or less ultrahigh resolution observation device are necessary for the study of the growth process and the damage process of the pinhole on this charge exchange foils, but there is no device which met the condition that we can observe for a long time, because of the very poor usage environment of the observer which is observed in high radiation and vacuum. Therefore we devised the observation system which applied the principle of the telescope that can always observe at ultrahigh resolution even with high radiation environment. As a result of comparison of various optical systems to enable high-resolution and materials can be used in radiation environments, and having chosen the best method, we have succeeded in producing the ultrahigh resolution observation device which could observe a subject of approximately 8m ahead at resolution of 8.3μm. In this article, we describe the development process, production, and the optics performance test of the ultrahigh resolution observation device. (author)

  4. Automated data processing of high-resolution mass spectra

    Hansen, Michael Adsetts Edberg; Smedsgaard, Jørn

    infusion of crude extracts into the source taking advantage of the high sensitivity, high mass resolution and accuracy and the limited fragmentation. Unfortunately, there has not been a comparable development in the data processing techniques to fully exploit gain in high resolution and accuracy of the...... massive amounts of data. We present an automated data processing method to quantitatively compare large numbers of spectra from the analysis of complex mixtures, exploiting the full quality of high-resolution mass spectra. By projecting all detected ions - within defined intervals on both the time and...... mass axis on to a fixed one-dimensional array, we obtain a vector that can be used directly as input in multivariate statistics or library search methods. We demonstrate that both cluster- and discriminant analysis as well as PCA (and related methods) can be applied directly on mass spectra from direct...

  5. Novel radiation hard microfabricated scintillation detectors with high spatial resolution

    Mapelli, A; Haguenauerc, M; Jiguet, S; Vico Triviño, N; Renaud, P

    2010-01-01

    A novel liquid scintillation detector with high spatial resolution is being developed with standard microfabrication techniques. It consists of a dense array of scintillating waveguides obtained by filling microfluidic channels with an organic liquid scintillator and optically coupled to a pixellated photodetector. Such a microfluidic device can be designed and processed to meet the requirements of a wide range of applications like medical imaging, homeland security and high-energy physics. High-spatial resolution miniaturized detectors as well as large-area detectors can easily be fabricated. The fabrication process of a prototype detector and experimental results are presented in this paper.

  6. Lynx: A High-Resolution Synthetic Aperture Radar

    Doerry, A.W.; Hensley, W.H.; Pace, F.; Stence, J.; Tsunoda, S.I.; Walker, B.C.; Woodring, M.

    1999-03-08

    Lynx is a high resolution, synthetic aperture radar (SAR) that has been designed and built by Sandia National Laboratories in collaboration with General Atomics (GA). Although Lynx may be operated on a wide variety of manned and unmanned platforms, it is primarily intended to be fielded on unmanned aerial vehicles. In particular, it may be operated on the Predator, I-GNAT, or Prowler II platforms manufactured by GA Aeronautical Systems, Inc. The Lynx production weight is less than 120 lb. and has a slant range of 30 km (in 4 mm/hr rain). It has operator selectable resolution and is capable of 0.1 m resolution in spotlight mode and 0.3 m resolution in stripmap mode. In ground moving target indicator mode, the minimum detectable velocity is 6 knots with a minimum target cross-section of 10 dBsm. In coherent change detection mode, Lynx makes registered, complex image comparisons either of 0.1 m resolution (minimum) spotlight images or of 0.3 m resolution (minimum) strip images. The Lynx user interface features a view manager that allows it to pan and zoom like a video camera. Lynx was developed under corporate finding from GA and will be manufactured by GA for both military and commercial applications. The Lynx system architecture will be presented and some of its unique features will be described. Imagery at the finest resolutions in both spotlight and strip modes have been obtained and will also be presented.

  7. High Resolution Model Intercomparison Project (HighResMIP)

    Haarsma, R. J.; Roberts, M.; P. L. Vidale; Senior, C. A.; Bellucci, A.; Bao, Q; Chang, P.; S. Corti; Fučkar, N. S.; Guemas, V; Hardenberg, J.; Hazeleger, W; Kodama, C.; Koenigk, T.; L. R. Leung

    2016-01-01

    Robust projections and predictions of climate variability and change, particularly at regional scales, rely on the driving processes being represented with fidelity in model simulations. The role of enhanced horizontal resolution in improved process representation in all components of the climate system is of growing interest, particularly as some recent simulations suggest the possibility for significant changes in both large-scale aspects of circulation, as well as improvements in small-sca...

  8. Developing Visual Editors for High-Resolution Haptic Patterns

    Cuartielles, David; Göransson, Andreas; Olsson, Tony; Stenslie, Ståle

    In this article we give an overview of our iterative work in developing visual editors for creating high resolution haptic patterns to be used in wearable, haptic feedback devices. During the past four years we have found the need to address the question of how to represent, construct and edit high...

  9. Subcutaneous Cysticercosis: Role of High Resolution Ultrasound in Diagnosis

    Sachin Lohra

    2014-02-01

    Full Text Available BACKGROUND: Though the commonest site of extraintestinal infestation with Taenia solium is brain, Subcutaneous cysticercosis is fairly common in asia. The advent of high resolution ultrasound, FNAC, and a heightened clinician awareness of the existence of isolated soft tissue cysticerci has probably supplanted the need for surgical intervention and excision biopsy in asymptomatic subcutaneous cysts, as cysts have high rate of spontaneous resolution. OBJECTIVES: - To observe role of high resolution ultrasound in diagnosis and need of surgical intervention in treatment of subcutaneous cysticercosis. MATERIALS and METHODS: retrospective study of seven cases of extraneural cysticercosis, all involving the subcutaneous tissues or muscles over the arms and torso. Either high resolution ultrasound, FNAC, or excision biopsy, or a combination of these were used to arrive at a diagnosis. All patients were followed up with serial ultrasounds. All patients received oral nitazoxanide for autoinfection. Surgical excision was resorted to in two patients, in whom it was possible to obtain a histopathologic diagnosis. RESULTS: of the seven cases of subcutaneous cysticercosis all have rural background, most of the patients (6 were vegetarian and one was non vegetarian. Age and gender of patient, size and duration of lesion were insignificant in establishing the diagnosis. High resolution ultrasound was highly significant in establishing the diagnosis over FNAC and histopathology. Five of the cases resolved spontaneously and surgical intervention was required only in two cases. INTERPRETATION and CONCLUSIONS: With heightened clinician awareness of the existence of isolated subcutaneous cysticercosis in patients with close animal contact, and the widespread availability of high resolution ultrasound and FNAC, subcutaneous cysticercosis can be diagnosed readily. Surgery can be avoided in the great majority of these patients, as the cysts mostly resolve on their own

  10. Laboratory characterization of a GPR antenna for high-resolution testing: radiation pattern and vertical resolution

    Pérez Gracia, María de la Vega; Capua, Daniel di; González Drigo, José Ramón; Pujades Beneit, Lluís

    2009-01-01

    High-resolution ground-penetrating radar (GPR) evaluations of structures are usually carried out using antennas with high nominal centre frequencies (between 1 and 2GHz). A comprehensive characterization of such an antenna would make it possible to determine the capabilities of a system and obtain accurate data interpretations. This paper describes the experimental determination of the radiation pattern of a commercial 1.6 GHz antenna, which forms part of a comprehensive experimental chara...

  11. High Resolution X-Ray Spectroscopy Using Microcalorimeters

    Kelley, R. L.

    1997-01-01

    During the past 13 years high resolution X ray spectrometers have been developed that use cryogenically cooled microcalorimeters. These devices have inherently high signal-to-noise by operating at temperatures below 0.1 K and can achieve an energy resolution of < 10 eV over the 0.1-10 keV band. Existing devices use doped semiconductor thermometers and typically employ HgTe absorbers. The energy resolution depends on achieving a low heat capacity for the device. For soft X ray applications a relatively thin absorber (approximately 1 micrometer) may be used and an energy resolution of approximately 7 eV has been achieved. For applications up to approximately 10 keV an absorber thickness of approximately 10 micrometer is required and the energy resolution is typically approximately 12 eV. Improvements to the energy resolution in this energy band could be achieved if the problems of thermalizing X rays in low heat capacity superconductors can be overcome. The recent work on transition edge thermometers by Irwin et nl. looks particularly promising because of the higher sensitivity achievable from a sharp superconducting transition. The relatively low impedance of such a device permits the use of a low noise SQUID amplifier for readout. This would also significantly reduce the cryogen heat load compared with JFETs required by higher impedance semiconductor thermometers.

  12. High Resolution X-Ray Spectroscopy Using Microcalorimeters

    Kelley, R. L.

    1997-01-01

    During the past 13 years high resolution X ray spectrometers have been developed that use cryogenically cooled microcalorimeters. These devices have inherently high signal-to-noise by operating at temperatures below 0.1 K and can achieve an energy resolution of thermometers and typically employ HgTe absorbers. The energy resolution depends on achieving a low heat capacity for the device. For soft X ray applications a relatively thin absorber (approximately 1 micrometer) may be used and an energy resolution of approximately 7 eV has been achieved. For applications up to approximately 10 keV an absorber thickness of approximately 10 micrometer is required and the energy resolution is typically approximately 12 eV. Improvements to the energy resolution in this energy band could be achieved if the problems of thermalizing X rays in low heat capacity superconductors can be overcome. The recent work on transition edge thermometers by Irwin et nl. looks particularly promising because of the higher sensitivity achievable from a sharp superconducting transition. The relatively low impedance of such a device permits the use of a low noise SQUID amplifier for readout. This would also significantly reduce the cryogen heat load compared with JFETs required by higher impedance semiconductor thermometers.

  13. Achieving High Resolution Timer Events in Virtualized Environment.

    Adamczyk, Blazej; Chydzinski, Andrzej

    2015-01-01

    Virtual Machine Monitors (VMM) have become popular in different application areas. Some applications may require to generate the timer events with high resolution and precision. This however may be challenging due to the complexity of VMMs. In this paper we focus on the timer functionality provided by five different VMMs-Xen, KVM, Qemu, VirtualBox and VMWare. Firstly, we evaluate resolutions and precisions of their timer events. Apparently, provided resolutions and precisions are far too low for some applications (e.g. networking applications with the quality of service). Then, using Xen virtualization we demonstrate the improved timer design that greatly enhances both the resolution and precision of achieved timer events. PMID:26177366

  14. High-resolution structure of viruses from random diffraction snapshots

    Hosseinizadeh, A; Dashti, A; Fung, R; D'Souza, R M; Ourmazd, A

    2014-01-01

    The advent of the X-ray Free Electron Laser (XFEL) has made it possible to record diffraction snapshots of biological entities injected into the X-ray beam before the onset of radiation damage. Algorithmic means must then be used to determine the snapshot orientations and thence the three-dimensional structure of the object. Existing Bayesian approaches are limited in reconstruction resolution typically to 1/10 of the object diameter, with the computational expense increasing as the eighth power of the ratio of diameter to resolution. We present an approach capable of exploiting object symmetries to recover three-dimensional structure to high resolution, and thus reconstruct the structure of the satellite tobacco necrosis virus to atomic level. Our approach offers the highest reconstruction resolution for XFEL snapshots to date, and provides a potentially powerful alternative route for analysis of data from crystalline and nanocrystalline objects.

  15. Historical high-resolution dynamic sea level variations

    Brunnabend, Sandra-Esther; Dijkstra, Henk A.; Kliphuis, Michael; van Werkhoven, Ben; Bal, Henri E.; Maassen, Jason; van Meersbergen, Maarten; Seinstra, Frank

    2014-05-01

    To investigate future changes in the dynamics of the ocean and therefore in dynamic sea level, ocean models need to be able to adequately represent oceanic dynamical processes. Therefore, resolving ocean eddies and representing boundary currents is of major importance. In this study, we investigate historical variations in dynamical sea surface height using the strongly eddying global version of the Parallel Ocean Program (POP). First, differences in high and low-resolution ocean model results (0.1 vs. 1.0 degree) were analyzed using a climatological atmospheric forcing dataset. Second, we forced the high-resolution model by atmospheric conditions over the period from 1950 to 2000 that are derived from a simulation using the ECHAM5-OM1 model (within the ESSENCE project, see www.knmi.nl/~sterl/Essence/). In general, the large-scale ocean fields of the POP model simulation agree well with those of the low-resolution ocean model (MPI-OM) results. Variations occur due to the different models used and, especially, due to the capability of the high-resolution POP model to resolve eddies. A comparison of high-resolution ocean model results with in-situ measurements, such as dynamic topography provided by altimetry, and salinity and temperature provided by the WOA2013, also show good agreement.

  16. High Resolution SPectrometer for HCT, Hanle: an update

    Sunetra, Giridhar; Sivarani, T.; Anantha, Ch.; Jayashree, Roy; Anand, M. N.; Anupama, G. C.; Mahesh, P. K.; Parihar, P. S.; Prabhu, T. P.; Singhal, A. K.; Sriram, S.; Sundararajan, M. S.

    A high resolution spectrometer for the 2m Himalayan Chandra Telescope (HCT) at Indian Astronomical Observatory (IAO) Hanle, is being built to meet the observational requirement of many advanced areas in astronomy requiring high spectral resolution. This instrument is based upon a modern design using a white pupil concept which has been adopted in several contemporary high resolution spectrometers. This design is known to reduce light losses due to vignetting and also provides the full spectral coverage (350nm-1000nm) in a single CCD frame. This design also incorporates additional features like image-slicer which would result in very high light efficiency. A peak throughput of 20% in visual range and throughput of 8% is expected at extreme blue and red wavelengths. The spectrometer would give resolutions of 60,000 and 30,000 in two resolution modes. In this contribution we describe the instrument and its environment and give an update on its development and science programs we propose to undertake.

  17. High-resolution streaming video integrated with UGS systems

    Rohrer, Matthew

    2010-04-01

    Imagery has proven to be a valuable complement to Unattended Ground Sensor (UGS) systems. It provides ultimate verification of the nature of detected targets. However, due to the power, bandwidth, and technological limitations inherent to UGS, sacrifices have been made to the imagery portion of such systems. The result is that these systems produce lower resolution images in small quantities. Currently, a high resolution, wireless imaging system is being developed to bring megapixel, streaming video to remote locations to operate in concert with UGS. This paper will provide an overview of how using Wifi radios, new image based Digital Signal Processors (DSP) running advanced target detection algorithms, and high resolution cameras gives the user an opportunity to take high-powered video imagers to areas where power conservation is a necessity.

  18. New vacuum solar telescope and observations with high resolution

    The New Vacuum Solar Telescope (NVST) is a one meter vacuum solar telescope that aims to observe fine structures on the Sun. The main goals of NVST are high resolution imaging and spectral observations, including measurements of the solar magnetic field. NVST is the primary ground-based facility used by the Chinese solar research community in this solar cycle. It is located by Fuxian Lake in southwest China, where the seeing is good enough to perform high resolution observations. We first introduce the general conditions at the Fuxian Solar Observatory and the primary science cases of NVST. Then, the basic structures of this telescope and instruments are described in detail. Finally, some typical high resolution data of the solar photosphere and chromosphere are also shown

  19. A high resolution powder diffractometer using focusing optics

    V Siruguri; P D Babu; M Gupta; A V Pimpale; P S Goyal

    2008-11-01

    In this paper, we describe the design, construction and performance of a new high resolution neutron powder diffractometer that has been installed at the Dhruva reactor, Trombay, India. The instrument employs novel design concepts like the use of bent, perfect crystal monochromator and open beam geometry, enabling the use of smaller samples. The resolution curve of the instrument was found to have little variation over a wide angular region and a / ∼ 0.3% has been achieved. The instrument provides sample environment of very low temperatures and high magnetic fields using a 7 Tesla cryogen-free superconducting magnet with a VTI having a temperature range of 1.5–320 K. The special sample environment and high resolution make this neutron powder diffractometer a very powerful facility for studying magnetic properties of materials.

  20. High spatial resolution diffusion tensor imaging and its applications

    Wang, J J

    2002-01-01

    Introduction Magnetic Resonance Imaging is at present the only imaging technique available to measure diffusion of water and metabolites in humans. It provides vital insights to brain connectivity and has proved to be an important tool in diagnosis and therapy planning in many neurological diseases such as brain tumour, ischaemia and multiple sclerosis. This project focuses on the development of a high resolution diffusion tensor imaging technique. In this thesis, the basic theory of diffusion tensor MR Imaging is presented. The technical challenges encountered during development of these techniques will be discussed, with proposed solutions. New sequences with high spatial resolution have been developed and the results are compared with the standard technique more commonly used. Overview The project aims at the development of diffusion tensor imaging techniques with a high spatial resolution. Chapter 2 will describe the basic physics of MRI, the phenomenon of diffusion and the measurement of diffusion by MRI...

  1. High Range Resolution Profile Automatic Target Recognition Using Sparse Representation

    Zhou Nuo; Chen Wei

    2010-01-01

    Sparse representation is a new signal analysis method which is receiving increasing attention in recent years.In this article,a novel scheme solving high range resolution profile automatic target recognition for ground moving targets is proposed.The sparse representation theory is applied to analyzing the components of high range resolution profiles and sparse coefficients are used to describe their features.Numerous experiments with the target type number ranging from 2 to 6 have been implemented.Results show that the proposed scheme not only provides higher recognition preciseness in real time,but also achieves more robust performance as the target type number increases.

  2. HIRES: the high resolution spectrograph for the E-ELT

    Zerbi, F. M.; Bouchy, F.; Fynbo, J.; Maiolino, R.; Piskunov, N.; Rebolo Lopez, R.; Santos, N.; Strassmeier, K.; Udry, S.; Vanzi, L.; Riva, M.; Basden, A.; Boisse, I.; Bonfils, X.; Buscher, D.; Cabral, A.; Dimarcantonio, P.; Di Varano, I.; Henry, D.; Monteiro, M.; Morris, T.; Murray, G.; Oliva, Ernesto; Parry, I.; Pepe, F.; Quirrenbach, A.; Rasilla, J. L.; Rees, P.; Stempels, E.; Valenziano, L.; Wells, M.; Wildi, F.; Origlia, L.; Allende Prieto, C.; Chiavassa, A.; Cristiani, S.; Figueira, P.; Gustafsson, B.; Hatzes, A.; Haehnelt, M.; Heng, K.; Israelian, G.; Kochukhov, O.; Lovis, C.; Marconi, A.; Martins, C. J. A. P.; Noterdaeme, P.; Petitjean, P.; Puzia, T.; Queloz, D.; Reiners, A.; Zoccali, M.

    2014-08-01

    The current instrumentation plan for the E-ELT foresees a High Resolution Spectrograph conventionally indicated as HIRES. Shaped on the study of extra-solar planet atmospheres, Pop-III stars and fundamental physical constants, HIRES is intended to embed observing modes at high-resolution (up to R=150000) and large spectral range (from the blue limit to the K band) useful for a large suite of science cases that can exclusively be tackled by the E-ELT. We present in this paper the solution for HIRES envisaged by the "HIRES initiative", the international collaboration established in 2013 to pursue a HIRES on E-ELT.

  3. High resolution X-ray spectroscopy of active galactic nuclei

    Krolik, Julian H.

    1990-01-01

    After a brief review of the principal problems of AGN research, selected potential high-resolution observations are discussed with a view toward assessing their scientific value and the degree of resolution they will require. Two classes of observations pertaining directly to AGNs are discussed. Fe K-alpha spectroscopy relevant to the dynamical and thermal character of the emission line zones; and measurement of resonance line absorption by highly-ionized species in BL Lac objects, which should provide information about entrainment of interstellar material by relativistic jets. A third class of potentially important observations uses AGNs as background light sources in order to directly measure the distance to clusters of galaxies.

  4. High-resolution seismic studies applied to injected geothermal fluids

    Smith, A.T.; Kasameyer, P.

    1985-01-01

    The application of high-resolution microseismicity studies to the problem of monitoring injected fluids is one component of the Geothermal Injection Monitoring Project at LLNL. The evaluation of microseismicity includes the development of field techniques, and the acquisition and processing of events during the initial development of a geothermal field. To achieve a specific detection threshold and location precision, design criteria are presented for seismic networks. An analysis of a small swarm near Mammoth Lakes, California, demonstrates these relationships and the usefulness of high-resolution seismic studies. A small network is currently monitoring the Mammoth-Pacific geothermal power plant at Casa Diablo as it begins production.

  5. Theoretical Problems in High Resolution Solar Physics, 2

    Athay, G. (Editor); Spicer, D. S. (Editor)

    1987-01-01

    The Science Working Group for the High Resolution Solar Observatory (HRSO) laid plans beginning in 1984 for a series of workshops designed to stimulate a broadbased input from the scientific community to the HRSO mission. These workshops have the dual objectives of encouraging an early start on the difficult theoretical problems in radiative transfer, magnetohydrodynamics, and plasma physics that will be posed by the HRSO data, and maintaining current discussions of results in high resolution solar studies. This workshop was the second in the series. The workshop format presented invited review papers during the formal sessions and contributed poster papers for discussions during open periods. Both are presented.

  6. Evaluation of High-Resolution Precipitation Estimates from Satellite Observations

    Arkin, P.; Turk, J.; Sapiano, M.; Ebert, B.

    2008-05-01

    During recent years, a number of satellite-derived, globally complete, high resolution precipitation products with a spatial resolution of at least 0.25° and a temporal resolution of at least three-hourly have been developed and produced regularly. These products generally merge geostationary infra-red data and polar- orbiting passive microwave data to take advantage of the high sampling of the infra-red and the superior quality of the microwave, and sometimes use ancillary data such as radar or gauge observations or model output. The Program to Evaluate High Resolution Precipitation Products (PEHRPP) was established by the International Precipitation Working Group to evaluate and inter-compare these datasets at a variety of spatial and temporal resolutions with the intent of guiding dataset developers and informing the user community regarding the error characteristics of these useful products. This presentation will summarize the current state of PEHRPP-related investigations, including the results from the International PEHRPP Workshop held in December 2007.

  7. Progress in high-resolution x-ray holographic microscopy

    Among the various types of x-ray microscopes that have been demonstrated, the holographic microscope has had the largest gap between promise and performance. The difficulties of fabricating x-ray optical elements have led some to view holography as the most attractive method for obtaining the ultimate in high resolution x-ray micrographs; however, we know of no investigations prior to 1987 that clearly demonstrated submicron resolution in reconstructed images. Previous efforts suffered from problems such as limited resolution and dynamic range in the recording media, low coherent x-ray flux, and aberrations and diffraction limits in visible light reconstruction. We have addressed the recording limitations through the use of an undulator x-ray source and high-resolution photoresist recording media. For improved results in the readout and reconstruction steps, we have employed metal shadowing and transmission electron microscopy, along with numerical reconstruction techniques. We believe that this approach will allow holography to emerge as a practical method of high-resolution x-ray microscopy. 30 refs., 4 figs

  8. A 4-channel 3 Tesla phased array receive coil for awake rhesus monkey fMRI and diffusion MRI experiments

    Khachaturian, Mark Haig

    2010-01-01

    Awake monkey fMRI and diffusion MRI combined with conventional neuroscience techniques has the potential to study the structural and functional neural network. The majority of monkey fMRI and diffusion MRI experiments are performed with single coils which suffer from severe EPI distortions which limit resolution. By constructing phased array coils for monkey MRI studies, gains in SNR and anatomical accuracy (i.e., reduction of EPI distortions) can be achieved using parallel imaging. The major...

  9. Multi-resolution voxel phantom modeling: a high-resolution eye model for computational dosimetry

    Caracappa, Peter F.; Rhodes, Ashley; Fiedler, Derek

    2014-09-01

    Voxel models of the human body are commonly used for simulating radiation dose with a Monte Carlo radiation transport code. Due to memory limitations, the voxel resolution of these computational phantoms is typically too large to accurately represent the dimensions of small features such as the eye. Recently reduced recommended dose limits to the lens of the eye, which is a radiosensitive tissue with a significant concern for cataract formation, has lent increased importance to understanding the dose to this tissue. A high-resolution eye model is constructed using physiological data for the dimensions of radiosensitive tissues, and combined with an existing set of whole-body models to form a multi-resolution voxel phantom, which is used with the MCNPX code to calculate radiation dose from various exposure types. This phantom provides an accurate representation of the radiation transport through the structures of the eye. Two alternate methods of including a high-resolution eye model within an existing whole-body model are developed. The accuracy and performance of each method is compared against existing computational phantoms.

  10. Multi-resolution voxel phantom modeling: a high-resolution eye model for computational dosimetry

    Voxel models of the human body are commonly used for simulating radiation dose with a Monte Carlo radiation transport code. Due to memory limitations, the voxel resolution of these computational phantoms is typically too large to accurately represent the dimensions of small features such as the eye. Recently reduced recommended dose limits to the lens of the eye, which is a radiosensitive tissue with a significant concern for cataract formation, has lent increased importance to understanding the dose to this tissue. A high-resolution eye model is constructed using physiological data for the dimensions of radiosensitive tissues, and combined with an existing set of whole-body models to form a multi-resolution voxel phantom, which is used with the MCNPX code to calculate radiation dose from various exposure types. This phantom provides an accurate representation of the radiation transport through the structures of the eye. Two alternate methods of including a high-resolution eye model within an existing whole-body model are developed. The accuracy and performance of each method is compared against existing computational phantoms. (paper)

  11. Quantifying and containing the curse of high resolution coronal imaging

    V. Delouille

    2008-10-01

    Full Text Available Future missions such as Solar Orbiter (SO, InterHelioprobe, or Solar Probe aim at approaching the Sun closer than ever before, with on board some high resolution imagers (HRI having a subsecond cadence and a pixel area of about (80 km2 at the Sun during perihelion. In order to guarantee their scientific success, it is necessary to evaluate if the photon counts available at these resolution and cadence will provide a sufficient signal-to-noise ratio (SNR.

    For example, if the inhomogeneities in the Quiet Sun emission prevail at higher resolution, one may hope to locally have more photon counts than in the case of a uniform source. It is relevant to quantify how inhomogeneous the quiet corona will be for a pixel pitch that is about 20 times smaller than in the case of SoHO/EIT, and 5 times smaller than TRACE.

    We perform a first step in this direction by analyzing and characterizing the spatial intermittency of Quiet Sun images thanks to a multifractal analysis. We identify the parameters that specify the scale-invariance behavior. This identification allows next to select a family of multifractal processes, namely the Compound Poisson Cascades, that can synthesize artificial images having some of the scale-invariance properties observed on the recorded images.

    The prevalence of self-similarity in Quiet Sun coronal images makes it relevant to study the ratio between the SNR present at SoHO/EIT images and in coarsened images. SoHO/EIT images thus play the role of "high resolution" images, whereas the "low-resolution" coarsened images are rebinned so as to simulate a smaller angular resolution and/or a larger distance to the Sun. For a fixed difference in angular resolution and in Spacecraft-Sun distance, we determine the proportion of pixels having a SNR preserved at high resolution given a particular increase in effective area. If scale-invariance continues to prevail at smaller scales, the conclusion reached

  12. New Challenges in High-Resolution Modeling of Hurricanes

    Chen, S. S.

    2006-12-01

    The extreme active Atlantic hurricane seasons in recent years have highlighted the urgent need for a better understanding of the factors that contribute to hurricane intensity and for development of the corresponding advanced hurricane prediction models to improve intensity forecasts. The lack of skill in present forecasts of hurricane structure and intensity may be attributed in part to deficiencies in the current prediction models: insufficient grid resolution, inadequate surface and boundary layer formulations, and the lack of full coupling to a dynamic ocean. The extreme high winds, intense rainfall, large ocean waves, and copious sea spray in hurricanes push the surface-exchange parameters for temperature, water vapor, and momentum into untested regimes. The recent modeling effort is to develop and test a fully coupled atmosphere-wave-ocean modeling system that is capable of resolving the eye and eyewall in a hurricane at ~1 km grid resolution. The new challenges for these very high resolution models are the corresponding physical representations at 1-km scale, including microphysics, sub-grid turbulence parameterization, atmospheric boundary layer, physical processes at the air-sea interface with surface waves among others. The lack of accurate initial conditions for high-resolution hurricane modeling presents another major challenge. Improvements in initial conditions rest on the use of more airborne and remotely sensed observations in high-resolution assimilation systems and on the application of advanced assimilation schemes to hurricanes. This study aimed to provide an overview of these new challenges using high-resolution model simulations of Hurricanes Isabel (2003), Frances (2004), Katrina and Rita (2005) that were observed extensively by two recent field programs, namely, the Coupled Boundary Layer Air-Sea Transfer (CBLAST)-Hurricane in 2003-2004 and the Hurricane Rainbands and Intensity Change Experiment (RAINEX) in 2005.

  13. Edge Preserving Image Coding For High Resolution Image Representation

    M. Nagaraju Naik; K. Kumar Naik; P. Rajesh Kumar

    2012-01-01

    Image coding for high resolution representation, with projection edge smoothening is been proposed in this work. In past works it is observed that image projection in larger dimension carried out by imageinterpolation results in high stretching effects at bounding regions of the objects in an image. Though focus is made towards achieving high quality accuracy in image projection very less work is made towards preserving the edge regions. in this paper a approach towards preserving edge at the...

  14. Resolution and sensitivity of high field nuclear magnetic resonance spectroscopy

    The arrival of very high field magnets and cryogenic circuitries, and the development of relaxation-optimized pulse sequences have added powerful tools for increasing sensitivity and resolution in NMR studies of biomacromolecules. The potential of these advances is not fully realized in practice, however, since current experimental protocols do not permit sufficient data sampling for optimal resolution in the indirect dimensions. Here we analyze quantitatively how increasing resolution in indirect dimensions affects the S/N ratio and compare this with currently used sampling routines. Optimal resolution would require sampling up to ∼3R2-1, and the S/N reaches a maximum at ∼1.2R2-1. Currently used data acquisition protocols rarely sample beyond 0.4R2-1, and extending evolution times would result in prohibitively long experiments. We show that a general solution to this problem is to use non-uniform sampling, where only a small subset of data points in the indirect sampling space are measured, and possibly different numbers of transients are collected for different evolution times. Coupled with modern methods of spectrum analysis, this strategy delivers substantially improved resolution and/or reduced measuring times compared to uniform sampling, without compromising sensitivity. Higher resolution in the indirect dimensions will facilitate the use of automated assignment programs

  15. High resolution radar satellite imagery analysis for safeguards applications

    For monitoring nuclear sites, the use of Synthetic Aperture Radar (SAR) imagery shows essential promises. Unlike optical remote sensing instruments, radar sensors operate under almost all weather conditions and independently of the sunlight, i.e. time of the day. Such technical specifications are required both for continuous and for ad-hoc, timed surveillance tasks. With Cosmo-Skymed, TerraSARX and Radarsat-2, high-resolution SAR imagery with a spatial resolution up to 1m has recently become available. Our work therefore aims to investigate the potential of high-resolution TerraSAR data for nuclear monitoring. This paper focuses on exploiting amplitude of a single acquisition, assessing amplitude changes and phase differences between two acquisitions, and PS-InSAR processing of an image stack.

  16. Strengthening IAEA safeguards using high-resolution commercial satellite imagery

    The proliferation of nuclear weapons poses great threat to international peace and security. How to strengthen the non-proliferation regime has become a central question. In May 1997, the IAEA Board of Governors adopted the Additional Safeguards Protocol to improve its ability to detect the undeclared production of fissile material. This new strengthened safeguards system has opened the door for the IAEA to use of all types of information, including the potential use of commercial satellite imagery. We have therefore been investigating the feasibility of strengthening IAEA safeguards using commercial satellite imagery. This paper explores the new roles of high-resolution commercial satellite imagery to monitor the nuclear proliferation. Based on our analysis on a number of one-meter resolution IKONOS commercial satellite images of nuclear facilities, we found that the new high-resolution commercial satellite imagery would play a new and valuable role in strengthening IAEA safeguards. (author)

  17. Portable electro-mechanically cooled high-resolution germanium detector

    Neufeld, K.W.; Ruhter, W.D.

    1995-05-01

    We have integrated a small, highly-reliable, electro-mechanical cryo-cooler with a high-resolution germanium detector for portable/field applications. The system weighs 6.8 kg and requires 40 watts of power to operate once the detector is cooled to its operating temperature. the detector is a 500 mm{sup 2} by 20-mm thick low-energy configuration that gives a full-width at half maximum (FWHM) energy resolution of 523 eV at 122 keV, when cooled with liquid nitrogen. The energy resolution of the detector, when cooled with the electro-mechanical cooler, is 570 eV at 122 keV. We have field tested this system in measurements of plutonium and uranium for isotopic and enrichment information using the MGA and MGAU analysis programs without any noticeable effects on the results.

  18. High resolution map of light pollution over Poland

    Netzel, Henryka; Netzel, Paweł

    2016-09-01

    In 1976 Berry introduced a simple mathematical equation to calculate artificial night sky brightness at zenith. In the original model cities, considered as points with given population, are only sources of light emission. In contrary to Berry's model, we assumed that all terrain surface can be a source of light. Emission of light depends on percent of built up area in a given cell. We based on Berry's model. Using field measurements and high-resolution data we obtained the map of night sky brightness over Poland in 100-m resolution. High resolution input data, combined with a very simple model, makes it possible to obtain detailed structures of the night sky brightness without complicating the calculations.

  19. High resolution electron microscopic study of tin dioxide crystals

    Smith, David J.; Bursill, L. A.; Wood, G. J.

    1983-11-01

    Crystals of Sb-doped tin dioxide have been examined by high resolution electron microscopy (≤2.3 Å point-to-point resolution) in [100], [001], and [1 overline111] zone axes projections, and images of twin interfaces, inclined defects, and a possible crystallographic shear plane have been recorded. Image simulations confirmed that the metal atom rows have been clearly resolved in each of these three low-index projections for specific electron-optical conditions. Image observation and consideration of the possible atomic arrangements about a (011)-type twin interface suggested that this resulted from a glide operation given by {1}/{2} (011) and a very close match with an experimental through-focal series was obtained using computer image simulations. The structural determination of crystal defects by high resolution electron microscopy is briefly discussed.

  20. High-resolution TFT-LCD for spatial light modulator

    Lee, JaeWon; Kim, Yong-Hae; Byun, Chun-Won; Pi, Jae-Eun; Oh, Himchan; Kim, GiHeon; Lee, Myung-Lae; Chu, Hye-Yong; Hwang, Chi-Sun

    2014-06-01

    SLM with very fine pixel pitch is needed for the holographic display system. Among various kinds of SLMs, commercially available high resolution LCoS has been widely used as a spatial light modulator. But the size of commercially available LCoS SLM is limited because the manufacturing technology of LCoS is based on the semiconductor process developed on small size Si wafer. Recently very high resolution flat panel display panel (~500ppi) was developed as a "retina display". Until now, the pixel pitch of flat panel display is several times larger than the pixel pitch of LCoS. But considering the possibility of shrink down the pixel pitch with advanced lithographic tools, the application of flat panel display will make it possible to build a SLM with high spatial bandwidth product. We simulated High resolution TFT-LCD panel on glass substrate using oxide semiconductor TFT with pixel pitch of 20um. And we considered phase modulation behavior of LC(ECB) mode. The TFT-LCD panel is reflective type with 4-metal structure with organic planarization layers. The technical challenge for high resolution large area SLM will be discussed with very fine pixel.

  1. High resolution muon computed tomography at neutrino beam facilities

    X-ray computed tomography (CT) has an indispensable role in constructing 3D images of objects made from light materials. However, limited by absorption coefficients, X-rays cannot deeply penetrate materials such as copper and lead. Here we show via simulation that muon beams can provide high resolution tomographic images of dense objects and of structures within the interior of dense objects. The effects of resolution broadening from multiple scattering diminish with increasing muon momentum. As the momentum of the muon increases, the contrast of the image goes down and therefore requires higher resolution in the muon spectrometer to resolve the image. The variance of the measured muon momentum reaches a minimum and then increases with increasing muon momentum. The impact of the increase in variance is to require a higher integrated muon flux to reduce fluctuations. The flux requirements and level of contrast needed for high resolution muon computed tomography are well matched to the muons produced in the pion decay pipe at a neutrino beam facility and what can be achieved for momentum resolution in a muon spectrometer. Such an imaging system can be applied in archaeology, art history, engineering, material identification and whenever there is a need to image inside a transportable object constructed of dense materials

  2. Conceptual design of a high-resolution π0 spectrometer

    This paper discusses the design of a high-resolution π0 spectrometer based on accurate measurements of the opening angle between the two γ rays from π0 decay. The first π0 spectrometer of this type was built at LAMPF and first operated in 1978. It has an energy resolution of 2 MeV and solid angle of about 1 msr. During the last 10 years a considerable body of work studying the π-nucleus and π-nucleon charge-exchange reaction has been carried out. Many experiments that are being proposed and considered require a more capable instrument. During the same period there has been substantial improvement in the technologies of photon calorimetry and charged particle vertex resolution. These improvements make possible a ten-fold improvement in the energy resolution of a π0 spectrometer. It is also possible to achieve large improvements in solid-angle and rate capabilities. This paper reviews and develops the physical principles involved in the design of an opening angle π0 spectrometer. It is also shown that these principles, combined with the goals of good energy resolution, large-solid angle, and high-rate capability, constrain the design of a practical instrument

  3. Real-time database for high resolution neutron monitor measurements

    The worldwide network of standardised neutron monitors is, after 50 years, still the state-of-the-art instrumentation to measure spectral variations of the primary cosmic ray component. These measurements are an ideal complement to space based cosmic ray measurements. Data from the approximately 50 IGY and NM64 neutron monitors is stored locally but also available through data collections sites like the World Data Center (WDC) or the IZMIRAN ftp server. The data from the WDC is in a standard format, but only hourly values are available. IZMIRAN collects the data in the best available time resolution, but the data arrives on the ftp server only hours, sometimes days, after the measurements. Also, the high time-resolution measurements of the different stations do not have a common format, a conversion routine for each station is needed before they can be used for scientific analysis. Supported by the 7th framework program of the European Commission, we are setting up a real-time database where high resolution cosmic ray measurements will be stored and accessible immediately after the measurement. Stations that do not have 1-minute resolution measurements will be upgraded to 1-minute or better resolution with an affordable standard registration system, that will submit the measurements to the database via the internet in real-time

  4. Super-resolution imaging of a single metal layer: high loss but superior resolution

    Guo, Kai; Liu, Jianlong; Zhou, Keya; Liu, Shutian

    2016-04-01

    In this work, we re-analyze the influence of the loss on the super-resolution imaging of a single metal layer superlens system and reveal its positive role of the imaging. The analysis is based on the surface plasmon polariton (SPP) theory. We show that SPP mode with high loss could suppress the amplification of evanescent waves and concentrate the energy, thus contribute to the imaging. We propose to surround the metal layer with high index medium to increase the loss of the SPP modes. The proposed structure shows better performance in super-resolution imaging than the low loss cases. Numerical simulations are performed to demonstrate the results by using two-dimensional finite element method.

  5. Hand-held high resolution gamma ray spectrometer

    A fully portable and a semi-portable high resolution gamma spectrometer are described. These instruments have the resolving capabilities that are inherent to germanium spectrometers and have the portability needed for health physics. The instruments are usable as a gamma-ray or x-ray fluorescence spectrometer

  6. Application of Classification Models to Pharyngeal High-Resolution Manometry

    Mielens, Jason D.; Hoffman, Matthew R.; Ciucci, Michelle R.; McCulloch, Timothy M.; Jiang, Jack J.

    2012-01-01

    Purpose: The authors present 3 methods of performing pattern recognition on spatiotemporal plots produced by pharyngeal high-resolution manometry (HRM). Method: Classification models, including the artificial neural networks (ANNs) multilayer perceptron (MLP) and learning vector quantization (LVQ), as well as support vector machines (SVM), were…

  7. Structure Identification in High-Resolution Transmission Electron Microscopic Images

    Vestergaard, Jacob Schack; Kling, Jens; Dahl, Anders Bjorholm;

    2014-01-01

    A connection between microscopic structure and macroscopic properties is expected for almost all material systems. High-resolution transmission electron microscopy is a technique offering insight into the atomic structure, but the analysis of large image series can be time consuming. The present...

  8. Dye laser light for high-resolution classical photography

    The test run with the bubble chamber HOLEBC in October 1981 offered the opportunity of checking the usefulness of de-speckled dye laser light for illumination purposes in high-resolution classical dark field photography of small bubble chambers. (orig./HSI)

  9. A DVD Spectroscope: A Simple, High-Resolution Classroom Spectroscope

    Wakabayashi, Fumitaka; Hamada, Kiyohito

    2006-01-01

    Digital versatile disks (DVDs) have successfully made up an inexpensive but high-resolution spectroscope suitable for classroom experiments that can easily be made with common material and gives clear and fine spectra of various light sources and colored material. The observed spectra can be photographed with a digital camera, and such images can…

  10. Human enamel structure studied by high resolution electron microscopy

    Human enamel structural features are characterized by high resolution electron microscopy. The human enamel consists of polycrystals with a structure similar to Ca10(PO4)6(OH)2. This article describes the structural features of human enamel crystal at atomic and nanometer level. Besides the structural description, a great number of high resolution images are included. Research into the carious process in human enamel is very important for human beings. This article firstly describes the initiation of caries in enamel crystal at atomic and unit-cell level and secondly describes the further steps of caries with structural and chemical demineralization. The demineralization in fact, is the origin of caries in human enamel. The remineralization of carious areas in human enamel has drawn more and more attention as its potential application is realized. This process has been revealed by high resolution electron microscopy in detail in this article. On the other hand, the radiation effects on the structure of human enamel are also characterized by high resolution electron microscopy. In order to reveal this phenomenon clearly, a great number of electron micrographs have been shown, and a physical mechanism is proposed. 26 references

  11. High resolution ultrasonography in isolated soft tissue and intramuscular cysticercosis

    Gaurav Sharma

    2016-01-01

    Conclusions: With the advent of high resolution ultrasonography and increased clinical awareness of the isolated soft tissue-intramuscular cysticercosis especially in endemic zone, a more conservative non-invasive approach can be applied both in diagnosis and treatment of these isolated cases of cysticercosis. [Int J Res Med Sci 2016; 4(1.000: 42-46

  12. High-Resolution Projection Microstereolithography for Patterning of Neovasculature.

    Raman, Ritu; Bhaduri, Basanta; Mir, Mustafa; Shkumatov, Artem; Lee, Min Kyung; Popescu, Gabriel; Kong, Hyunjoon; Bashir, Rashid

    2016-03-01

    To gain a quantitative understanding of the way cells sense, process, and respond to dynamic environmental signals in real-time requires developing in vitro model systems that accurately replicate the 3D structure and function of native tissue. A high-resolution projection stereolithography apparatus (μSLA) capable of multimaterial and grayscale 3D patterning of cells and biomaterials at <5 μm resolution is presented. Murine cells (fibroblasts, myoblasts, endothelial, and bone marrow stromal cells) encapsulated within photosensitive hydrogels using the μSLA remain viable up to two weeks after fabrication. Harnessing the high-resolution fabrication capabilities of this machine, sub-millimeter scale angiogenic cell-encapsulating patches designed to promote targeted growth of neovasculature are printed, as assessed in vitro via enzyme-linked immunosorbent assay (ELISA) and in ovo via a chick chorioallantoic membrane assay (CAM). This application establishes the μSLA as an enabling technology that is widely adaptable to any application that requires high-resolution patterning of cells and cells signals. By providing an efficient and robust method of engineering microscale tissues with encapsulated cells, this apparatus has a range of applications including fundamental studies of extracellular matrix interactions, high throughput drug testing of physiologically relevant substitutes for native tissue, and programmable tissue engineering for applications in regenerative medicine. PMID:26696464

  13. High energy-resolution inelastic X-ray scattering

    A brief review is presented of various aspects of high energy-resolution inelastic X-ray scattering based on synchrotron sources. We show what kinematical advantages are provided by the photon probe and propose mirror and monochromator designs to achieve an optically efficient beam line for inelastic X-ray scattering

  14. Drizzle Measurements Using High Spectral Resolution Lidar and Radar Data

    Eloranta, Edwin W.

    2016-06-01

    The ratio of millimeter radar and High Spectral Resolution Lidar (HSRL) backscatter are used to determine drizzle rates which are compared to conventional ground based measurements. The robustly calibrated HSRL backscatter cross section provides advantages over measurements made with traditional lidars.

  15. Depolarization Measurements with the High Spectral Resolution Lidar

    Eloranta, E. W.; Piironen, P.

    1996-01-01

    This paper describes modifications to the University of Wisconsin High Spectral Resolution Lidar (HSRL) which permit very precise depolarization measurements in addition to optical depth, backscatter cross section, and extinction cross section measurements. Because HSRL separates the lidar return into aerosol and molecular contributions, they can be measured separately.

  16. Drizzle Measurements Using High Spectral Resolution Lidar and Radar Data

    Eloranta Edwin W.

    2016-01-01

    The ratio of millimeter radar and High Spectral Resolution Lidar (HSRL) backscatter are used to determine drizzle rates which are compared to conventional ground based measurements. The robustly calibrated HSRL backscatter cross section provides advantages over measurements made with traditional lidars.

  17. High energy resolution off-resonant X-ray spectroscopy

    Wojciech, Blachucki [Univ. of Fribourg (Switzerland). Dept. of Physics

    2015-10-16

    This work treats of the high energy resolution off-resonant X-ray spectroscopy (HEROS) method of determining the density of unoccupied electronic states in the vicinity of the absorption edge. HEROS is an alternative to the existing X-ray absorption spectroscopy (XAS) methods and opens the way for new studies not achievable before.

  18. Remote parallel rendering for high-resolution tiled display walls

    Nachbaur, Daniel

    2014-11-01

    © 2014 IEEE. We present a complete, robust and simple to use hardware and software stack delivering remote parallel rendering of complex geometrical and volumetric models to high resolution tiled display walls in a production environment. We describe the setup and configuration, present preliminary benchmarks showing interactive framerates, and describe our contributions for a seamless integration of all the software components.

  19. High-resolution neutrons diffraction techniques for strain scanning

    Mikula, Pavol; Vrána, Miroslav; Lukáš, Petr; Wagner, V.

    Dordrecht : Kluwer Academic Publishers, 2002 - (Gdoutos, E.), s. 457-466 ISBN 1-4020-0683-7 R&D Projects: GA ČR GV202/97/K038; GA AV ČR IAA1048003 Keywords : high-resolution * neutron diffraction techniques * Bragg diffraction optics Subject RIV: BM - Solid Matter Physics ; Magnetism

  20. Texture analysis of high-resolution FLAIR images for TLE

    Jafari-Khouzani, Kourosh; Soltanian-Zadeh, Hamid; Elisevich, Kost

    2005-04-01

    This paper presents a study of the texture information of high-resolution FLAIR images of the brain with the aim of determining the abnormality and consequently the candidacy of the hippocampus for temporal lobe epilepsy (TLE) surgery. Intensity and volume features of the hippocampus from FLAIR images of the brain have been previously shown to be useful in detecting the abnormal hippocampus in TLE. However, the small size of the hippocampus may limit the texture information. High-resolution FLAIR images show more details of the abnormal intensity variations of the hippocampi and therefore are more suitable for texture analysis. We study and compare the low and high-resolution FLAIR images of six epileptic patients. The hippocampi are segmented manually by an expert from T1-weighted MR images. Then the segmented regions are mapped on the corresponding FLAIR images for texture analysis. The 2-D wavelet transforms of the hippocampi are employed for feature extraction. We compare the ability of the texture features from regular and high-resolution FLAIR images to distinguish normal and abnormal hippocampi. Intracranial EEG results as well as surgery outcome are used as gold standard. The results show that the intensity variations of the hippocampus are related to the abnormalities in the TLE.

  1. HIGH RESOLUTION RESISTIVITY LEAK DETECTION DATA PROCESSING & EVALUATION MEHTODS & REQUIREMENTS

    SCHOFIELD JS

    2007-10-04

    This document has two purposes: {sm_bullet} Describe how data generated by High Resolution REsistivity (HRR) leak detection (LD) systems deployed during single-shell tank (SST) waste retrieval operations are processed and evaluated. {sm_bullet} Provide the basic review requirements for HRR data when Hrr is deployed as a leak detection method during SST waste retrievals.

  2. Data Evaluation Procedure for High-resolution Neutron Diffraction Methods

    Strunz, Pavel; Lukáš, Petr; Neov, Dimitar

    2001-01-01

    Roč. 9, - (2001), s. 99-106. ISSN 1023-8166 R&D Projects: GA ČR GV202/97/K038 Institutional research plan: CEZ:AV0Z1048901 Keywords : high-resolution neutron diffraction * profile analysis * modeling Subject RIV: BM - Solid Matter Physics ; Magnetism

  3. High resolution observations of optically weak flat spectrum radio sources

    The authors present high resolution radio maps of 4 flat spectrum radio objects which have very faint optical counterparts. These objects show either relatively compact 'core-jet' structure or are 'compact double' sources. The authors suggest a possible link between the absence of optical activity and the existence of compact radio double structure

  4. Bombs at High Resolution. I. Morphological Evidence for Photospheric Reconnection

    Watanabe, H.; Vissers, G.; Kitai, R.; Rouppe van der Voort, L.H.M.; Rutten, R.J.

    2011-01-01

    High-resolution imaging-spectroscopy movies of solar active region NOAA 10998 obtained with the Crisp Imaging Spectropolarimeter at the Swedish 1-m Solar Telescope show very bright, rapidly flickering, flame-like features that appear intermittently in the wings of the Balmer Hα line in a region with

  5. Workshop on high-resolution, large-acceptance spectrometers

    Zeidman, B. (ed.)

    1981-01-01

    The purpose of the Workshop on High-Resolution, Large-Acceptance Spectrometers was to provide a means for exchange of information among those actively engaged in the design and construction of these new spectrometers. Thirty-seven papers were prepared for the data base.

  6. Towards very high resolution RPC-PET for small animals

    We present imaging results of needle-like and planar 22Na sources obtained with a prototype of a high-acceptance small-animal positron emission tomograph based on resistive plate chambers (RPC-PET). The maximum-likelihood expectation-maximization (MLEM) reconstruction of the acquired data yielded an excellent and stable resolution of 0.4 mm FWHM

  7. High-resolution studies of the orbits and multiplanar reconstruction

    With high resolution, which could be called 'target scanning', the CT examination can be tailored to the patient's need. This trend will doubtless increase and CT, like radiology, will become organ-oriented. We have been using this technique in the evaluation of ear diseases, pituitary tumours and parathyroid tumours with exciting results. (orig./AJ)

  8. High resolution CT of the cervical spinal cord

    High resolution CT demonstrates the anatomy of the spine, spinal canal and spinal cord. In many cases, the non-contrast HRCT images provide enough information to guide patient management. Where necessary, intravenously-enhanced HRCT and metrizamide HRCT may be employed to gain additional data. Other studies may be obviated in many cases. (orig.)

  9. Plant respirometer enables high resolution of oxygen consumption rates

    Foster, D. L.

    1966-01-01

    Plant respirometer permits high resolution of relatively small changes in the rate of oxygen consumed by plant organisms undergoing oxidative metabolism in a nonphotosynthetic state. The two stage supply and monitoring system operates by a differential pressure transducer and provides a calibrated output by digital or analog signals.

  10. High-resolution palaeoclimatology of the last millennium

    Vinther, Bo Møllesøe; Jones, P.D.; Briffa, K.R.;

    2009-01-01

    Palaeoclimatology • high-resolution • last millennium • tree rings • dendroclimatology • chronology • uncertainty • corals • ice-cores • speleothems • documentary evidence • instrumental records • varves • borehole temperature • marine sediments • composite plus scaling • CPS • climate field...

  11. Topography improvements in MEMS DMs for high-contrast, high-resolution imaging Project

    National Aeronautics and Space Administration — This project will develop and demonstrate an innovative microfabrication process to substantially improve the surface quality achievable in high-resolution...

  12. High resolution atomic force microscopy of double-stranded RNA

    Ares, Pablo; Fuentes-Perez, Maria Eugenia; Herrero-Galán, Elías; Valpuesta, José M.; Gil, Adriana; Gomez-Herrero, Julio; Moreno-Herrero, Fernando

    2016-06-01

    Double-stranded (ds) RNA mediates the suppression of specific gene expression, it is the genetic material of a number of viruses, and a key activator of the innate immune response against viral infections. The ever increasing list of roles played by dsRNA in the cell and its potential biotechnological applications over the last decade has raised an interest for the characterization of its mechanical properties and structure, and that includes approaches using Atomic Force Microscopy (AFM) and other single-molecule techniques. Recent reports have resolved the structure of dsDNA with AFM at unprecedented resolution. However, an equivalent study with dsRNA is still lacking. Here, we have visualized the double helix of dsRNA under near-physiological conditions and at sufficient resolution to resolve the A-form sub-helical pitch periodicity. We have employed different high-sensitive force-detection methods and obtained images with similar spatial resolution. Therefore, we show here that the limiting factors for high-resolution AFM imaging of soft materials in liquid medium are, rather than the imaging mode, the force between the tip and the sample and the sharpness of the tip apex.Double-stranded (ds) RNA mediates the suppression of specific gene expression, it is the genetic material of a number of viruses, and a key activator of the innate immune response against viral infections. The ever increasing list of roles played by dsRNA in the cell and its potential biotechnological applications over the last decade has raised an interest for the characterization of its mechanical properties and structure, and that includes approaches using Atomic Force Microscopy (AFM) and other single-molecule techniques. Recent reports have resolved the structure of dsDNA with AFM at unprecedented resolution. However, an equivalent study with dsRNA is still lacking. Here, we have visualized the double helix of dsRNA under near-physiological conditions and at sufficient resolution to

  13. High resolution full-spectrum water Raman lidar

    LIU FuChao; YI Fan; JIA JingYu; ZHANG YunPeng; ZHANG ShaoDong; YU ChangMing; TAN Ying

    2012-01-01

    Knowledge of the temporal-spatial distribution of water content in atmosphere and water phase change in cloud is important for atmospheric study.For this purpose,we have developed a high resolution full-spectrum water Raman lidar that can collect Raman signals from ice,water droplets and water vapor simultaneously.A double-grating polychromator and a 32-channel photomultiplier-tube detector are used to obtain a spectral resolution of ~0.19 nm in the full Raman spectrum range of water.Preliminary observations present the water Raman spectrum characteristics of both the mixed-phase cloud and humid air under cloudless condition.

  14. High resolution alpha spectroscopy with low cost photodiodes

    Energy resolution for α-spectra comparable to that from good quality surface barrier detectors has been obtained with inexpensive commercial silicon photodiodes. Using a low noise charge-sensitive preamplifier, an alpha energy resolution of less than 15 keV (fwhm) was achieved for 5.486 MeV α-particles from 241Am; this performance enables fine structure peaks to be clearly observed for 239Pu, 241Am, and 244Cm in a mixed α-source. The energy response was found to be highly linear and stable over long periods of operation. Results for other radiations are also briefly described. (orig.)

  15. Design for a focusing high-resolution neutron crystal diffractometer

    Ionita, I. E-mail: onu@cc.nuclear.ro; Stoica, A.D.; Popovici, M.; Popa, N.C

    1999-07-21

    A new concept of high-resolution focusing configuration begins to be accepted as an alternative solution to the existing conventional configurations. Among the earliest work performed in this direction is that performed at the Institute for Nuclear Research, Pitesti. These results are presented below. The experimentally determined resolution properties for two focusing configurations obtained at TRIGA reactor Pitesti and at VVRS reactor Bucharest are given in order to be compared with those obtained for the conventional ones. The principles to get focusing in crystal neutron diffractometry are presented. The main characteristics for a focusing instrument are given. (author)

  16. Design for a focusing high-resolution neutron crystal diffractometer

    Ionita, I.; Stoica, A. D.; Popovici, M.; Popa, N. C.

    1999-07-01

    A new concept of high-resolution focusing configuration begins to be accepted as an alternative solution to the existing conventional configurations. Among the earliest work performed in this direction is that performed at the Institute for Nuclear Research, Pitesti. These results are presented below. The experimentally determined resolution properties for two focusing configurations obtained at TRIGA reactor Pitesti and at VVRS reactor Bucharest are given in order to be compared with those obtained for the conventional ones. The principles to get focusing in crystal neutron diffractometry are presented. The main characteristics for a focusing instrument are given.

  17. A distributed stream temperature model using high resolution temperature observations

    M. C. Westhoff; Savenije, H. H. G.; W. M. J. Luxemburg; Stelling, G. S.; Van de Giesen, N.C.; Selker, J. S.; L. Pfister; Uhlenbrook, S.

    2007-01-01

    Highly distributed temperature data are used as input and as calibration data for a temperature model of a first order stream in Luxembourg. A DTS (Distributed Temperature Sensing) fiber optic cable with a length of 1500 m is used to measure stream water temperature with a spatial resolution of 0.5 m and a temporal resolution of 2 min. With the observations four groundwater inflows are found and quantified (both temperature and relative discharge). They are used as input for the distributed t...

  18. High resolution near edge x-ray spectroscopy

    A technique to suppress the core-hole lifetime broadening in near- edge x-ray spectroscopy is presented. A simple theoretical explanation based on total energy conservation in the fluorescence process is given to explain the improved resolution. The experimental arrangement is shown together with an application to the LIII edge of dysprosium. Furthermore, the application of high-resolution fluorescence spectroscopy in the study of magnetism is presented. The spin-resolved absorption spectra from MnF2 are shown as an example

  19. Design for a focusing high-resolution neutron crystal diffractometer

    Ionita, I; Popovici, M; Popa, N C

    1999-01-01

    A new concept of high-resolution focusing configuration begins to be accepted as an alternative solution to the existing conventional configurations. Among the earliest work performed in this direction is that performed at the Institute for Nuclear Research, Pitesti. These results are presented below. The experimentally determined resolution properties for two focusing configurations obtained at TRIGA reactor Pitesti and at VVRS reactor Bucharest are given in order to be compared with those obtained for the conventional ones. The principles to get focusing in crystal neutron diffractometry are presented. The main characteristics for a focusing instrument are given. (author)

  20. Advances in DNA sequencing technologies for high resolution HLA typing.

    Cereb, Nezih; Kim, Hwa Ran; Ryu, Jaejun; Yang, Soo Young

    2015-12-01

    This communication describes our experience in large-scale G group-level high resolution HLA typing using three different DNA sequencing platforms - ABI 3730 xl, Illumina MiSeq and PacBio RS II. Recent advances in DNA sequencing technologies, so-called next generation sequencing (NGS), have brought breakthroughs in deciphering the genetic information in all living species at a large scale and at an affordable level. The NGS DNA indexing system allows sequencing multiple genes for large number of individuals in a single run. Our laboratory has adopted and used these technologies for HLA molecular testing services. We found that each sequencing technology has its own strengths and weaknesses, and their sequencing performances complement each other. HLA genes are highly complex and genotyping them is quite challenging. Using these three sequencing platforms, we were able to meet all requirements for G group-level high resolution and high volume HLA typing. PMID:26423536

  1. Scalable, flexible and high resolution patterning of CVD graphene.

    Hofmann, Mario; Hsieh, Ya-Ping; Hsu, Allen L; Kong, Jing

    2014-01-01

    The unique properties of graphene make it a promising material for interconnects in flexible and transparent electronics. To increase the commercial impact of graphene in those applications, a scalable and economical method for producing graphene patterns is required. The direct synthesis of graphene from an area-selectively passivated catalyst substrate can generate patterned graphene of high quality. We here present a solution-based method for producing patterned passivation layers. Various deposition methods such as ink-jet deposition and microcontact printing were explored, that can satisfy application demands for low cost, high resolution and scalable production of patterned graphene. The demonstrated high quality and nanometer precision of grown graphene establishes the potential of this synthesis approach for future commercial applications of graphene. Finally, the ability to transfer high resolution graphene patterns onto complex three-dimensional surfaces affords the vision of graphene-based interconnects in novel electronics. PMID:24189709

  2. Spatial resolution effects on the assessment of evapotranspiration in olive orchards using high resolution thermal imagery

    Santos, Cristina; Zarco-Tejada, Pablo J.; Lorite, Ignacio J.; Allen, Richard G.

    2013-04-01

    The use of remote sensing techniques for estimating surface energy balance and water consumption has significantly improved the characterization of the agricultural systems by determining accurate information about crop evapotranspiration and stress, mainly for extensive crops. However the use of these methodologies for woody crops has been low due to the difficulty in the accurate characterization of these crops, mainly caused by a coarse resolution of the imagery provided by the most widely used satellites (such as Landsat 5 and 7). The coarse spatial resolution provided by these satellite sensors aggregates into a single pixel the tree crown, sunlit and shaded soil components. These surfaces can each exhibit huge differences in temperature, albedo and vegetation indexes calculated in the visible, near infrared and short-wave infrared regions. Recent studies have found that the use of energy balance approaches can provide useful results for non-homogeneous crops (Santos et al., 2012) but detailed analysis is required to determine the effect of the spatial resolution and the aggregation of the scene components in these heterogeneous canopies. In this study a comparison between different spatial resolutions has been conducted using images from Landsat 7 (with thermal resolution of 60m) and from an airborne thermal (with resolution of 80 cm) flown over olive orchards at different dates coincident with the Landsat overpass. The high resolution thermal imagery was resampled at different scales to generate images with spatial resolution ranging from 0.8 m up to 120m (thermal resolution for Landsat 5 images). The selection of the study area was made to avoid those areas with missing Landsat 7 data caused by SLC-off gaps. The selected area has a total area of around 2500 ha and is located in Southern Spain, in the province of Malaga. The selected area is mainly cultivated with olive orchards with different crop practices (rainfed, irrigated, high density, young and adult

  3. X-ray high-resolution diffraction using refractive lenses

    Drakopoulos, Michael; Snigirev, Anatoly; Snigireva, Irina; Schilling, Jörg

    2005-01-01

    Refractive x-ray lenses have recently been applied for imaging and scanning microscopy with hard x rays. We report the application of refractive lenses in an optical scheme for high-resolution x-ray diffraction, performed at a high brilliance synchrotron radiation source. An experimental proof of principle and a theoretical discussion are presented. In particular, we observe the x-ray diffraction pattern from a two-dimensional photonic crystal with 4.2 µm periodicity, which normally is employ...

  4. Scalable, flexible and high resolution patterning of CVD graphene

    Hofmann, Mario; Hsieh, Ya-Ping; Hsu, Allen L.; Kong, Jing

    2013-12-01

    The unique properties of graphene make it a promising material for interconnects in flexible and transparent electronics. To increase the commercial impact of graphene in those applications, a scalable and economical method for producing graphene patterns is required. The direct synthesis of graphene from an area-selectively passivated catalyst substrate can generate patterned graphene of high quality. We here present a solution-based method for producing patterned passivation layers. Various deposition methods such as ink-jet deposition and microcontact printing were explored, that can satisfy application demands for low cost, high resolution and scalable production of patterned graphene. The demonstrated high quality and nanometer precision of grown graphene establishes the potential of this synthesis approach for future commercial applications of graphene. Finally, the ability to transfer high resolution graphene patterns onto complex three-dimensional surfaces affords the vision of graphene-based interconnects in novel electronics.The unique properties of graphene make it a promising material for interconnects in flexible and transparent electronics. To increase the commercial impact of graphene in those applications, a scalable and economical method for producing graphene patterns is required. The direct synthesis of graphene from an area-selectively passivated catalyst substrate can generate patterned graphene of high quality. We here present a solution-based method for producing patterned passivation layers. Various deposition methods such as ink-jet deposition and microcontact printing were explored, that can satisfy application demands for low cost, high resolution and scalable production of patterned graphene. The demonstrated high quality and nanometer precision of grown graphene establishes the potential of this synthesis approach for future commercial applications of graphene. Finally, the ability to transfer high resolution graphene patterns onto

  5. High-resolution anoscopy: Unchartered territory for gastroenterologists?

    Albuquerque, Andreia

    2015-01-01

    High-resolution anoscopy (HRA) is a procedure where patients with an increased risk of anal cancer, like men who have sex with men, human immunodeficiency virus infected individuals, transplant patients and women with a history of lower genital tract neoplasia, with abnormal anal cytology results, are submitted to anal and perianal visualization under magnification. This will allow for a better detection of anal high-grade lesions that can be treated, in an effort to prevent anal cancer. Anal...

  6. High-resolution schemes for hyperbolic conservation laws

    Harten, A.

    1982-01-01

    A class of new explicit second order accurate finite difference schemes for the computation of weak solutions of hyperbolic conservation laws is presented. These highly nonlinear schemes are obtained by applying a nonoscillatory first order accurae scheme to an appropriately modified flux function. The so derived second order accurate schemes achieve high resolution while preserving the robustness of the original nonoscillatory first order accurate scheme.

  7. Design of high-resolution Fourier transform lens

    Zhang, Lei; Zhong, Xing; Jin, Guang

    2007-12-01

    With the development of optical information processing, high-resolution Fourier transform lens has often been used in holographic data storage system, spatial filtering and observation of particles. This paper studies the optical design method of high-resolution Fourier transform optical lenses system, which could be used in particles observation and holographic data storage system. According to Fourier transform relation between object and its frequency plane and the theory of geometrical optics, the system with working wavelength 532nm and resolution 3μm was designed based on ZEMAX. A multi-configuration method was adopted to optimize the system's lenses. In the optical system, a diaphragm was placed at the system's spectrum plane and the system demanded a low vacuum to cut down the influences of atmosphere and other particles. The result of finite element analysis indicated that the influences of vacuum pumping to optics spacing and mirror surface shape very minor, and the imaging quality not being affected. This system has many advantages, such as simple structure, good image quality and a high resolution of 3μm. So it has a wide application prospect and can be used both in holographic data storage system and particles observation.

  8. High resolution imaging with impulse based thermoacoustic tomography

    Kellnberger, Stephan; Hajiaboli, Amir; Sergiadis, George; Razansky, Daniel; Ntziachristos, Vasilis

    2011-07-01

    Existing imaging modalities like microwave- or radiofrequency (RF) induced thermoacoustic tomography systems show the potential for resolving structures deep inside tissue due to the high penetration properties of RF. However, one of the major drawbacks of existing thermoacoustic tomography systems with pulse modulated carrier frequency excitation is the compromise between efficient signal generation and attainable spatial resolution. In order to overcome limitations of conventional thermoacoustic imaging methods, we herein present and experimentally validate our novel approach towards high resolution thermoacoustic tomography. Instead of carrier-frequency amplification, we utilize ultrahigh-energy electromagnetic impulses at nanosecond duration with near-field energy coupling, thus maintaining thermoacoustic signal strength without compromising spatial resolution. Preliminary experiments on highly absorbing objects, consisting of copper wires with characteristic sizes of ~100 μm, reveal the resolution performance which yields 160 μm. Furthermore, benefits like its cost effectiveness, simplicity and compactness with the potential application in small animal imaging as well as human body imaging show that thermoacoustic tomography with impulse excitation is a promising imaging modality which has a broad range of applications.

  9. SPI: A high resolution imaging spectrometer for INTEGRAL

    SPI (Spectrometer for INTEGRAL) is a high spectral resolution gamma-ray telescope using cooled germanium detectors that will be flown on board the INTEGRAL mission in 2001. It consists of an array of 19 closely-packed germanium detectors surrounded by an active bismuth germanate (BGO) anti-coincidence shield. The instrument operates over the energy range 20 keV to 8 MeV with an energy resolution of 1-5 keV. A tungsten coded-aperture mask located 1.7 m from the detector array provides imaging over a 15 deg. fully-coded field-of-view with an angular resolution of ∼3 deg. The point source narrow-line sensitivity is estimated to be 3-7x10-6 ph cm-2 s-1 over most of the range of the instrument (E>200 keV) for a 106 s observation. With its combination of high sensitivity, high spectral resolution and imaging, SPI will improve significantly over the performance of previous instruments such as HEAO-3, OSSE, and Comptel. It can be expected to take a major step forward in experimental studies in nuclear astrophysics. The SPI instrument is being developed under the auspices of the European Space Agency by a large international team of scientists and engineers in both Europe and the United States

  10. Photoacoustic lymphatic imaging with high spatial-temporal resolution

    Martel, Catherine; Yao, Junjie; Huang, Chih-Hsien; Zou, Jun; Randolph, Gwendalyn J.; Wang, Lihong V.

    2014-11-01

    Despite its critical function in coordinating the egress of inflammatory and immune cells out of tissues and maintaining fluid balance, the causative role of lymphatic network dysfunction in pathological settings is still understudied. Engineered-animal models and better noninvasive high spatial-temporal resolution imaging techniques in both preclinical and clinical studies will help to improve our understanding of different lymphatic-related pathologic disorders. Our aim was to take advantage of our newly optimized noninvasive wide-field fast-scanning photoacoustic (PA) microcopy system to coordinately image the lymphatic vasculature and its flow dynamics, while maintaining high resolution and detection sensitivity. Here, by combining the optical-resolution PA microscopy with a fast-scanning water-immersible microelectromechanical system scanning mirror, we have imaged the lymph dynamics over a large field-of-view, with high spatial resolution and advanced detection sensitivity. Depending on the application, lymphatic vessels (LV) were spectrally or temporally differentiated from blood vessels. Validation experiments were performed on phantoms and in vivo to identify the LV. Lymphatic flow dynamics in nonpathological and pathological conditions were also visualized. These results indicate that our newly developed PA microscopy is a promising tool for lymphatic-related biological research.

  11. High resolution study of high mass pairs and high transverse momentum particles

    Preliminary experiments involving the high resolution spectrometer (experiment 605) at Fermilab are described. The spectrometer is designed for the study of pairs of particles at large invariant masses and single particles at large transverse momenta. A number of applications of the apparatus in the study of Drell-Yan processes, e.g. transverse momentum measurement, are discussed

  12. On temporal correlations in high-resolution frequency counting

    Dunker, Tim; Rønningen, Ole Petter

    2016-01-01

    We analyze noise properties of time series of frequency data from different counting modes of a Keysight 53230A frequency counter. We use a 10 MHz reference signal from a passive hydrogen maser connected via phase-stable Huber+Suhner Sucoflex 104 cables to the reference and input connectors of the counter. We find that the high resolution gap-free (CONT) frequency counting process imposes long-term correlations in the output data, resulting in a modified Allan deviation that is characteristic of random walk phase noise. Equally important, the CONT mode results in a frequency bias. In contrast, the counter's undocumented raw continuous mode (RCON) yields unbiased frequency stability estimates with white phase noise characteristics, and of a magnitude consistent with the counter's 20 ps single-shot resolution. Furthermore, we demonstrate that a 100-point running average filter in conjunction with the RCON mode yields resolution enhanced frequency estimates with flicker phase noise characteristics. For instance,...

  13. High Resolution K-Band Spectroscopy of Selected M Dwarfs

    Nakajima, Tadashi

    2013-06-01

    We propose to obtain high-resolution K-band spectra of selected M dwarfs to study stellar properties such as effective temperature and metallicity. M dwarfs are under scrutiny as potential planet hosts. They have sufficiently low masses and small radii that exoplanets induce considerably larger reflex velocities and transit depths than an identical planet would around larger, more massive hosts. The low temperatures of M dwarfs imply short-period planets are in the habitable zone. However, due to the cool atmosphere, the characterization of M dwarfs at visible wavelengths has been rather difficult and the previously known stellar parameters have been rather crude. Recently a new method to use medium resolution K-band spectroscopy to determine the effective temperature and metallicity was devised. The purposes of this proposal is to examine the validity of the new method with a spectral resolution one order of magnitude higher and, if possible, to find a better method to determine the stellar properties.

  14. Overview on high-resolution ocean modeling in JAMSTEC

    Michio Kawamiya

    2014-01-01

    In view of the importance of ocean component for representing climate change,efforts are underway to implement a high-resolution nesting model system in Model for Interdisciplinary Research on Climate (MI-ROC) for the North Pacific using the same ocean model as used in the coupled model MIROC5. By comparing double (10 km for the northwestern Pacific,50 km for the rest of the Pacific) and triple (double nesting plus 2 km resolution near Japan) nesting,it turns out that relative vorticity is drastically enhanced near Japan with 2 km resolution. It is hoped that such an elaborated nesting system will reveal detailed processes for the ocean heat uptake by,e.g.,intermediate water and mode water formation for which the“perturbed region”near Japan is the key region.

  15. Construction of a high resolution electron beam profile monitor

    Bremsstrahlung from an electron beam on a heavy target can be used to image the beam profile using collimators and slits. The limiting resolution using this system is determined by Fresnel diffraction, and is ∼ √(λd/2), where λ is the photon wavelength and d is determined by the linear dimensions of the system. For linear colliders this resolution could be a few nm. The highest resolution requires detectors which see only high energy, (small λ), photons, and this is accomplished by converting photons to pairs, and detecting Cherenkov light in a nearly forward angle with a CCD detector or streak camera. Tests are planned at the Argonne APS and SLAC FFTB

  16. Bendable X-ray Optics for High Resolution Imaging

    Gubarev, M.; Ramsey, B.; Kilaru, K.; Atkins, C.; Broadway, D.

    2014-01-01

    Current state-of the-art for x-ray optics fabrication calls for either the polishing of massive substrates into high-angular-resolution mirrors or the replication of thin, lower-resolution, mirrors from perfectly figured mandrels. Future X-ray Missions will require a change in this optics fabrication paradigm in order to achieve sub-arcsecond resolution in light-weight optics. One possible approach to this is to start with perfectly flat, light-weight surface, bend it into a perfect cone, form the desired mirror figure by material deposition, and insert the resulting mirror into a telescope structure. Such an approach is currently being investigated at MSFC, and a status report will be presented detailing the results of finite element analyses, bending tests and differential deposition experiments.

  17. A high-resolution two-dimensional imaging velocimeter

    Velocity interferometers are typically used to measure velocities of surfaces at a single point or along an imaged line as a function of time. We describe an optical arrangement that enables high-resolution measurements of the two-dimensional velocity field across a shock front or shocked interface. The technique is employed to measure microscopic fluctuations in shock fronts that have passed through materials being considered as ablators for indirect-drive inertial confinement fusion. With picosecond time resolution the instrument captures velocity modes with wavelengths as short as 2.5 μm at a resolution of ∼10 m/s rms on velocity fields averaging many km/s over an 800 μm field of view.

  18. Advances toward high spectral resolution quantum X-ray calorimetry

    Moseley, S. H.; Kelley, R. L.; Schoelkopf, R. J.; Szymkowiak, A. E.; Mccammon, D.

    1988-01-01

    Thermal detectors for X-ray spectroscopy combining high spectral resolution and quantum efficiency have been developed. These microcalorimeters measure the energy released in the absorption of a single photon by sensing the rise in temperature of a small absorbing structure. The ultimate energy resolution of such a device is limited by the thermodynamic power fluctuations in the thermal link between the calorimeter and isothermal bath and can in principle be made as low as 1 eV. The performance of a real device is degraded due to noise contributions such as excess 1/f noise in the thermistor and incomplete conversion of energy into phonons. The authors report some recent advances in thermometry, X-ray absorption and thermalization, fabrication techniques, and detector optimization in the presence of noise. These improvements have resulted in a device with a spectral resolution of 17 eV FWHM, measured at 6 keV.

  19. Ultra high resolution soft x-ray tomography

    Ultra high resolution three dimensional images of a microscopic test object were made with soft x-rays using a scanning transmission x-ray microscope. The test object consisted of two different patterns of gold bars on silicon nitride windows that were separated by ∼5 microm. A series of nine 2-D images of the object were recorded at angles between -50 to +55 degrees with respect to the beam axis. The projections were then combined tomographically to form a 3-D image by means of an algebraic reconstruction technique (ART) algorithm. A transverse resolution of ∼ 1,000 angstrom was observed. Artifacts in the reconstruction limited the overall depth resolution to ∼ 6,000 angstrom, however some features were clearly reconstructed with a depth resolution of ∼ 1,000 angstrom. A specially modified ART algorithm and a constrained conjugate gradient (CCG) code were also developed as improvements over the standard ART algorithm. Both of these methods made significant improvements in the overall depth resolution, bringing it down to ∼ 1,200 angstrom overall. Preliminary projection data sets were also recorded with both dry and re-hydrated human sperm cells over a similar angular range

  20. Ultra high resolution soft x-ray tomography

    Ultra high resolution three dimensional images of a microscopic test object were made with soft x-rays using a scanning transmission x-ray microscope. The test object consisted of two different patterns of gold bars on silicon nitride windows that were separated by ∼5μm. A series of nine 2-D images of the object were recorded at angles between -50 to +55 degrees with respect to the beam axis. The projections were then combined tomographically to form a 3-D image by means of an algebraic reconstruction technique (ART) algorithm. A transverse resolution of ∼1000 Angstrom was observed. Artifacts in the reconstruction limited the overall depth resolution to ∼6000 Angstrom, however some features were clearly reconstructed with a depth resolution of ∼1000 Angstrom. A specially modified ART algorithm and a constrained conjugate gradient (CCG) code were also developed as improvements over the standard ART algorithm. Both of these methods made significant improvements in the overall depth resolution bringing it down to ∼1200 Angstrom overall. Preliminary projection data sets were also recorded with both dry and re-hydrated human sperm cells over a similar angular range

  1. Characterization of high-resolution HafSOx inorganic resists

    Oleksak, R. P.; Herman, G. S.

    2014-04-01

    Inorganic resists are of considerable interest for advanced lithography at the nanoscale due to the potential for high resolution, low line width roughness (LWR), and high sensitivity. Historically inorganic resists suffered from low sensitivity, however approaches have been identified to increase sensitivity while maintaining high contrast. An aqueous precursor of Hf(OH)4-2x-2y(O2)x(SO4)y·qH2O (HafSOx) has been demonstrated with excellent sensitivity to EUV and electrons, while still obtaining high resolution and low LWR. In this work, we characterize both HafSOx precursor solutions and spin-coated thin films using high-resolution transmission electron microscopy (HR-TEM) with energy-dispersive X-ray spectroscopy (EDS) elemental analysis. HR-TEM of precursor solutions drop cast onto TEM grids confirmed the presence of nanoscale particles. HR-TEM cross sectional images showed that spin-coated HafSOx films are initially uniform in appearance and composition for thin (12 nm) films, however thicker (30 nm) films display segregation of species leading to multilayer structures. Regardless of film thickness, extended exposure to the high energy TEM electron beam induces significant migration of oxygen species to the Si interface. These species result in the formation of SiOx layers that increase in thickness with an increase in TEM electron beam dose. Sulfate is also very mobile in the films and likely assists in the significant condensation exhibited in completely processed films.

  2. High Resolution X-ray-Induced Acoustic Tomography

    Xiang, Liangzhong; Tang, Shanshan; Ahmad, Moiz; Xing, Lei

    2016-05-01

    Absorption based CT imaging has been an invaluable tool in medical diagnosis, biology, and materials science. However, CT requires a large set of projection data and high radiation dose to achieve superior image quality. In this letter, we report a new imaging modality, X-ray Induced Acoustic Tomography (XACT), which takes advantages of high sensitivity to X-ray absorption and high ultrasonic resolution in a single modality. A single projection X-ray exposure is sufficient to generate acoustic signals in 3D space because the X-ray generated acoustic waves are of a spherical nature and propagate in all directions from their point of generation. We demonstrate the successful reconstruction of gold fiducial markers with a spatial resolution of about 350 μm. XACT reveals a new imaging mechanism and provides uncharted opportunities for structural determination with X-ray.

  3. The Gaia FGK Benchmark Stars - High resolution spectral library

    Blanco-Cuaresma, S; Jofré, P; Heiter, U

    2014-01-01

    Context. An increasing number of high resolution stellar spectra is available today thanks to many past and ongoing spectroscopic surveys. Consequently, numerous methods have been developed in order to perform an automatic spectral analysis on a massive amount of data. When reviewing published results, biases arise and they need to be addressed and minimized. Aims. We are providing a homogeneous library with a common set of calibration stars (known as the Gaia FGK Benchmark Stars) that will allow to assess stellar analysis methods and calibrate spectroscopic surveys. Methods. High resolution and signal-to-noise spectra were compiled from different instruments. We developed an automatic process in order to homogenize the observed data and assess the quality of the resulting library. Results. We built a high quality library that will facilitate the assessment of spectral analyses and the calibration of present and future spectroscopic surveys. The automation of the process minimizes the human subjectivity and e...

  4. High Resolution Optical Spectra of HBC 722 after Outburst

    Lee, Jeong-Eun; Lee, Sang-Gak; Sung, Hyun-Il; Lee, Byeong-Cheol; Sung, Hwankyung; Green, Joel D; Jeon, Young-Beom

    2011-01-01

    We report the results of our high resolution optical spectroscopic monitoring campaign ($\\lambda$ = 3800 -- 8800 A, R = 30000 -- 45000) of the new FU Orionis-type object HBC 722. We observed HBC 722 with the BOES 1.8-m telescope between 2010 November 26 and 2010 December 29 and FU Orionis itself on 2011 January 26. We detect a number of previously unreported high-resolution K I and Ca II lines beyond 7500 A. We resolve the H$\\alpha$ and Ca II line profiles into three velocity components, which we attribute to both disk and outflow. The increased accretion during outburst can heat the disk to produce the relatively narrow absorption feature and launch outflows appearing as high velocity blue and redshifted broad features.

  5. High-spatial-resolution nanoparticle x-ray fluorescence tomography

    Larsson, Jakob C.; Vâgberg, William; Vogt, Carmen; Lundström, Ulf; Larsson, Daniel H.; Hertz, Hans M.

    2016-03-01

    X-ray fluorescence tomography (XFCT) has potential for high-resolution 3D molecular x-ray bio-imaging. In this technique the fluorescence signal from targeted nanoparticles (NPs) is measured, providing information about the spatial distribution and concentration of the NPs inside the object. However, present laboratory XFCT systems typically have limited spatial resolution (>1 mm) and suffer from long scan times and high radiation dose even at high NP concentrations, mainly due to low efficiency and poor signal-to-noise ratio. We have developed a laboratory XFCT system with high spatial resolution (sub-100 μm), low NP concentration and vastly decreased scan times and dose, opening up the possibilities for in-vivo small-animal imaging research. The system consists of a high-brightness liquid-metal-jet microfocus x-ray source, x-ray focusing optics and an energy-resolving photon-counting detector. By using the source's characteristic 24 keV line-emission together with carefully matched molybdenum nanoparticles the Compton background is greatly reduced, increasing the SNR. Each measurement provides information about the spatial distribution and concentration of the Mo nanoparticles. A filtered back-projection method is used to produce the final XFCT image.

  6. Imaging collagen type I fibrillogenesis with high spatiotemporal resolution

    Stamov, Dimitar R, E-mail: stamov@jpk.com [JPK Instruments AG, Bouchéstrasse 12, 12435 Berlin (Germany); Stock, Erik [JPK Instruments AG, Bouchéstrasse 12, 12435 Berlin (Germany); Franz, Clemens M [DFG-Center for Functional Nanostructures (CFN), Karlsruhe Institute of Technology (KIT), Wolfgang-Gaede-Strasse 1a, 76131 Karlsruhe (Germany); Jähnke, Torsten; Haschke, Heiko [JPK Instruments AG, Bouchéstrasse 12, 12435 Berlin (Germany)

    2015-02-15

    Fibrillar collagens, such as collagen type I, belong to the most abundant extracellular matrix proteins and they have received much attention over the last five decades due to their large interactome, complex hierarchical structure and high mechanical stability. Nevertheless, the collagen self-assembly process is still incompletely understood. Determining the real-time kinetics of collagen type I formation is therefore pivotal for better understanding of collagen type I structure and function, but visualising the dynamic self-assembly process of collagen I on the molecular scale requires imaging techniques offering high spatiotemporal resolution. Fast and high-speed scanning atomic force microscopes (AFM) provide the means to study such processes on the timescale of seconds under near-physiological conditions. In this study we have applied fast AFM tip scanning to study the assembly kinetics of fibrillar collagen type I nanomatrices with a temporal resolution reaching eight seconds for a frame size of 500 nm. By modifying the buffer composition and pH value, the kinetics of collagen fibrillogenesis can be adjusted for optimal analysis by fast AFM scanning. We furthermore show that amplitude-modulation imaging can be successfully applied to extract additional structural information from collagen samples even at high scan rates. Fast AFM scanning with controlled amplitude modulation therefore provides a versatile platform for studying dynamic collagen self-assembly processes at high resolution. - Highlights: • Continuous non-invasive time-lapse investigation of collagen I fibrillogenesis in situ. • Imaging of collagen I self-assembly with high spatiotemporal resolution. • Application of setpoint modulation to study the hierarchical structure of collagen I. • Observing real-time formation of the D-banding pattern in collagen I.

  7. Imaging collagen type I fibrillogenesis with high spatiotemporal resolution

    Fibrillar collagens, such as collagen type I, belong to the most abundant extracellular matrix proteins and they have received much attention over the last five decades due to their large interactome, complex hierarchical structure and high mechanical stability. Nevertheless, the collagen self-assembly process is still incompletely understood. Determining the real-time kinetics of collagen type I formation is therefore pivotal for better understanding of collagen type I structure and function, but visualising the dynamic self-assembly process of collagen I on the molecular scale requires imaging techniques offering high spatiotemporal resolution. Fast and high-speed scanning atomic force microscopes (AFM) provide the means to study such processes on the timescale of seconds under near-physiological conditions. In this study we have applied fast AFM tip scanning to study the assembly kinetics of fibrillar collagen type I nanomatrices with a temporal resolution reaching eight seconds for a frame size of 500 nm. By modifying the buffer composition and pH value, the kinetics of collagen fibrillogenesis can be adjusted for optimal analysis by fast AFM scanning. We furthermore show that amplitude-modulation imaging can be successfully applied to extract additional structural information from collagen samples even at high scan rates. Fast AFM scanning with controlled amplitude modulation therefore provides a versatile platform for studying dynamic collagen self-assembly processes at high resolution. - Highlights: • Continuous non-invasive time-lapse investigation of collagen I fibrillogenesis in situ. • Imaging of collagen I self-assembly with high spatiotemporal resolution. • Application of setpoint modulation to study the hierarchical structure of collagen I. • Observing real-time formation of the D-banding pattern in collagen I

  8. Microfabrication of High Resolution X-ray Magnetic Calorimeters

    Metallic magnetic calorimeter (MMC) is one of the most promising x-ray detector technologies for providing the very high energy resolution needed for future astronomical x-ray imaging spectroscopy. For this purpose, we have developed micro-fabricated 5x5 arrays of MMC of which each individual pixel has excellent energy resolution as good as 3.4 eV at 6 keV x-ray. Here we report on the fabrication techniques developed to achieve good resolution and high efficiency. These include: processing of a thin insulation layer for strong magnetic coupling between the AuEr sensor film and the niobium pick-up coil; production of overhanging absorbers for enhanced efficiency of x-ray absorption; fabrication on SiN membranes to minimize the effects on energy resolution from athermal phonon loss. We have also improved the deposition of the magnetic sensor film such that the film magnetization is nearly completely that is expected from the AuEr sputter target bulk material. In addition, we have included a study of a positional sensitive design, the Hydra design, which allows thermal coupling of four absorbers to a common MMC sensor and circuit.

  9. Decadal climate predictions with an high resolution coupled model

    Monerie, P. A.; Valcke, S.; Moine, M. P.; Maisonnave, E.; Coquart, L.; Cassou, C.; Terray, L.

    2014-12-01

    We analyze the decadal prediction skill of sea surface temperature variability with a high resolution coupled Ocean-Atmosphere General Circulation Model (OAGCM). The HR CERFACS was developed at the CERFACS (Centre Européen de Recherche et de Formation Avancée en Calcul Scientifique) laboratory in the framework of the EU-FP7 SPECS (Seasonal-to-decadal climate Predictions for the improvement of European Climate Services) project in order to address the question of decadal predictability with the use of a high spatial resolution. The atmospheric model is ARPEGE/IFS with a T359 spectral truncature and the oceanic model is NEMO at 0.25° resolution including the LIM2 sea ice model. Each hindcasts consist of a 10-members ensemble integrated over a 10-years period. These hindcasts are full-field initialized every year from 1993 to 2009 and initial oceanic state is given by the GLORYS2V1 (0.25° resolution) sea-surface temperatures. Members of a given ensemble (one initialization date) are generated by perturbations of the atmospheric initial conditions. We study the predictability of the global sea-surface temperature focusing on the Atlantic Multidecadal Oscillation (AMO), the Pacific Decadal Oscillation (PDO), the North Atlantic Subpolar Gyre (SPG) and the El-Nino Southern Oscillation (ENSO). We also investigate the prediction skill of the Atlantic Meridional Overturning Circulation (AMOC).

  10. High resolution multiplexed functional imaging in live embyros (Conference Presentation)

    Xu, Dongli; Peng, Leilei

    2016-03-01

    Optical projection tomography (OPT) creates isotropic 3D imaging of tissue. Two approaches exist today: Wide-field OPT illuminates the entire sample and acquires projection images with a camera; Scanning-laser optical tomography (SLOT) generates the projection with a moving laser beam and point detector. SLOT has superior light collecting efficiency than wide-field optical tomography, making it ideal for tissue fluorescence imaging. Regardless the approach, traditional OPT has to compromise between the resolution and the depth of view. In traditional SLOT, the focused Gaussian beam diverges quickly from the focused plane, making it impossible to achieve high resolution imaging through a large volume specimen. We report using Bessel beam instead of Gaussian beam to perform SLOT. By illuminating samples with a narrow Bessel beam throughout an extended depth, high-resolution projection images can be measured in large volume. Under Bessel illumination, the projection image contains signal from annular-rings of the Bessel beam. Traditional inverse Radon transform of these projections will result in ringing artifacts in reconstructed imaging. Thus a modified 3D filtered back projection algorithm is developed to perform tomography reconstructing of Bessel-illuminated projection images. The resulting 3D imaging is free of artifact and achieved cellular resolution in extended sample volume. The system is applied to in-vivo imaging of transgenic Zebrafish embryos. Results prove Bessel SLOT a promising imaging method in development biology research.

  11. High-resolution electron microscopy of advanced materials

    Mitchell, T.E.; Kung, H.H.; Sickafus, K.E.; Gray, G.T. III; Field, R.D.; Smith, J.F. [Los Alamos National Lab., NM (United States). Materials Science and Technology Div.

    1997-11-01

    This final report chronicles a three-year, Laboratory Directed Research and Development (LDRD) project at Los Alamos National Laboratory (LANL). The High-Resolution Electron Microscopy Facility has doubled in size and tripled in quality since the beginning of the three-year period. The facility now includes a field-emission scanning electron microscope, a 100 kV field-emission scanning transmission electron microscope (FE-STEM), a 300 kV field-emission high-resolution transmission electron microscope (FE-HRTEM), and a 300 kV analytical transmission electron microscope. A new orientation imaging microscope is being installed. X-ray energy dispersive spectrometers for chemical analysis are available on all four microscopes; parallel electron energy loss spectrometers are operational on the FE-STEM and FE-HRTEM. These systems enable evaluation of local atomic bonding, as well as chemical composition in nanometer-scale regions. The FE-HRTEM has a point-to-point resolution of 1.6 {angstrom}, but the resolution can be pushed to its information limit of 1 {angstrom} by computer reconstruction of a focal series of images. HRTEM has been used to image the atomic structure of defects such as dislocations, grain boundaries, and interfaces in a variety of materials from superconductors and ferroelectrics to structural ceramics and intermetallics.

  12. 3 Tesla multiparametric MRI for GTV-definition of Dominant Intraprostatic Lesions in patients with Prostate Cancer – an interobserver variability study

    To evaluate the interobserver variability of gross tumor volume (GTV) - delineation of Dominant Intraprostatic Lesions (DIPL) in patients with prostate cancer using published MRI criteria for multiparametric MRI at 3 Tesla by 6 different observers. 90 GTV-datasets based on 15 multiparametric MRI sequences (T2w, diffusion weighted (DWI) and dynamic contrast enhanced (DCE)) of 5 patients with prostate cancer were generated for GTV-delineation of DIPL by 6 observers. The reference GTV-dataset was contoured by a radiologist with expertise in diagnostic imaging of prostate cancer using MRI. Subsequent GTV-delineation was performed by 5 radiation oncologists who received teaching of MRI-features of primary prostate cancer before starting contouring session. GTV-datasets were contoured using Oncentra Masterplan® and iplan® Net. For purposes of comparison GTV-datasets were imported to the Artiview® platform (Aquilab®), GTV-values and the similarity indices or Kappa indices (KI) were calculated with the postulation that a KI > 0.7 indicates excellent, a KI > 0.6 to < 0.7 substantial and KI > 0.5 to < 0.6 moderate agreement. Additionally all observers rated difficulties of contouring for each MRI-sequence using a 3 point rating scale (1 = easy to delineate, 2 = minor difficulties, 3 = major difficulties). GTV contouring using T2w (KI-T2w = 0.61) and DCE images (KI-DCE = 0.63) resulted in substantial agreement. GTV contouring using DWI images resulted in moderate agreement (KI-DWI = 0.51). KI-T2w and KI-DCE was significantly higher than KI-DWI (p = 0.01 and p = 0.003). Degree of difficulty in contouring GTV was significantly lower using T2w and DCE compared to DWI-sequences (both p < 0.0001). Analysis of delineation differences revealed inadequate comparison of functional (DWI, DCE) to anatomical sequences (T2w) and lack of awareness of non-specific imaging findings as a source of erroneous delineation. Using T2w and DCE sequences at 3 Tesla for GTV-definition of DIPL in

  13. Comparison of 3D cube FLAIR with 2D FLAIR for multiple sclerosis imaging at 3 tesla

    Purpose: Three-dimensional (3 D) MRI sequences allow improved spatial resolution with good signal and contrast properties as well as multiplanar reconstruction. We sought to compare Cube, a 3 D FLAIR sequence, to a standard 2 D FLAIR sequence in multiple sclerosis (MS) imaging. Materials and Methods: Examinations were performed in the clinical routine on a 3.0 Tesla scanner. 12 patients with definite MS were included. Lesions with MS-typical properties on the images of Cube FLAIR and 2 D FLAIR sequences were counted and allocated to different brain regions. Signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) were calculated. Results: With 384 the overall number of lesions found with Cube FLAIR was significantly higher than with 2 D FLAIR (N = 221). The difference was mostly accounted for by supratentorial lesions (N = 372 vs. N = 216) while the infratentorial lesion counts were low in both sequences. SNRs and CNRs were significantly higher in CUBE FLAIR with the exception of the CNR of lesion to gray matter, which was not significantly different. Conclusion: Cube FLAIR showed a higher sensitivity for MS lesions compared to a 2 D FLAIR sequence. 3 D FLAIR might replace 2 D FLAIR sequences in MS imaging in the future. (orig.)

  14. Is the body-coil at 3 Tesla feasible for the MRI evaluation of the painful knee? A comparative study

    The purpose of this study was to compare the in-built body coil of the 3.0-Tesla (T) scanner with a dedicated surface coil of a 1.5 T system regarding knee imaging. We performed an intraindividual prospective clinical trial on 17 patients with knee pain using magnetic resonance imaging (MRI) at 1.5 and 3.0 T systems equipped with identical gradient systems. Proton-density-weighted turbo spin echo sequences with the same spatial resolution and comparable contrast parameters were used. A quantitative measurement of signal to noise ratio (SNR), relative contrast (RC) and contrast to noise ratio (CNR) between muscle and bone marrow was performed, followed by a qualitative assessment of anatomic/pathologic structures and the extent of artefacts. At 3.0 T, 30 lesions (91%) compared to 33 lesions at 1.5 T were detected. The SNR/CNR/RC were moderately reduced at 3.0 T versus 1.5 T (muscle 42 vs 47 and bone 83 vs 112/46 vs 69/0.33 vs 0.43). Motion artefacts from the pulsating popliteal artery were significantly increased at 3.0 T. A visible and measurable signal loss occurred at 3.0 T using the built-in body coil compared with the dedicated 1.5 T knee coil, but nearly all clinically important information could be obtained. (orig.)

  15. Comparison of 3D cube FLAIR with 2D FLAIR for multiple sclerosis imaging at 3 tesla

    Patzig, M.; Brueckmann, H.; Fesl, G. [Muenchen Univ. (Germany). Dept. of Neuroradiology; Burke, M. [GE Healthcare, Solingen (Germany)

    2014-05-15

    Purpose: Three-dimensional (3 D) MRI sequences allow improved spatial resolution with good signal and contrast properties as well as multiplanar reconstruction. We sought to compare Cube, a 3 D FLAIR sequence, to a standard 2 D FLAIR sequence in multiple sclerosis (MS) imaging. Materials and Methods: Examinations were performed in the clinical routine on a 3.0 Tesla scanner. 12 patients with definite MS were included. Lesions with MS-typical properties on the images of Cube FLAIR and 2 D FLAIR sequences were counted and allocated to different brain regions. Signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) were calculated. Results: With 384 the overall number of lesions found with Cube FLAIR was significantly higher than with 2 D FLAIR (N = 221). The difference was mostly accounted for by supratentorial lesions (N = 372 vs. N = 216) while the infratentorial lesion counts were low in both sequences. SNRs and CNRs were significantly higher in CUBE FLAIR with the exception of the CNR of lesion to gray matter, which was not significantly different. Conclusion: Cube FLAIR showed a higher sensitivity for MS lesions compared to a 2 D FLAIR sequence. 3 D FLAIR might replace 2 D FLAIR sequences in MS imaging in the future. (orig.)

  16. Coregistration of high-resolution Mars orbital images

    Sidiropoulos, Panagiotis; Muller, Jan-Peter

    2015-04-01

    The systematic orbital imaging of the Martian surface started 4 decades ago from NASA's Viking Orbiter 1 & 2 missions, which were launched in August 1975, and acquired orbital images of the planet between 1976 and 1980. The result of this reconnaissance was the first medium-resolution (i.e. ≤ 300m/pixel) global map of Mars, as well as a variety of high-resolution images (reaching up to 8m/pixel) of special regions of interest. Over the last two decades NASA has sent 3 more spacecraft with onboard instruments for high-resolution orbital imaging: Mars Global Surveyor (MGS) having onboard the Mars Orbital Camera - Narrow Angle (MOC-NA), Mars Odyssey having onboard the Thermal Emission Imaging System - Visual (THEMIS-VIS) and the Mars Reconnaissance Orbiter (MRO) having on board two distinct high-resolution cameras, Context Camera (CTX) and High-Resolution Imaging Science Experiment (HiRISE). Moreover, ESA has the multispectral High resolution Stereo Camera (HRSC) onboard ESA's Mars Express with resolution up to 12.5m since 2004. Overall, this set of cameras have acquired more than 400,000 high-resolution images, i.e. with resolution better than 100m and as fine as 25 cm/pixel. Notwithstanding the high spatial resolution of the available NASA orbital products, their accuracy of areo-referencing is often very poor. As a matter of fact, due to pointing inconsistencies, usually form errors in roll attitude, the acquired products may actually image areas tens of kilometers far away from the point that they are supposed to be looking at. On the other hand, since 2004, the ESA Mars Express has been acquiring stereo images through the High Resolution Stereo Camera (HRSC), with resolution that is usually 12.5-25 metres per pixel. The achieved coverage is more than 64% for images with resolution finer than 20 m/pixel, while for ~40% of Mars, Digital Terrain Models (DTMs) have been produced with are co-registered with MOLA [Gwinner et al., 2010]. The HRSC images and DTMs

  17. High Resolution Measurements and Electronic Structure Calculations of a Diazanaphthalene

    Gruet, Sébastien; Goubet, Manuel; Pirali, Olivier

    2014-06-01

    Polycyclic Aromatic Hydrocarbons (PAHs) have long been suspected to be the carriers of so called Unidentified Infrared Bands (UIBs). Most of the results published in the literature report rotationally unresolved spectra of pure carbon as well as heteroatom-containing PAHs species. To date for this class of molecules, the principal source of rotational informations is ruled by microwave (MW) spectroscopy while high resolution measurements reporting rotational structure of the infrared (IR) vibrational bands are very scarce. Recently, some high resolution techniques provided interesting new results to rotationally resolve the IR and far-IR bands of these large carbonated molecules of astrophysical interest. One of them is to use the bright synchrotron radiation as IR continuum source of a high resolution Fourier transform (FTIR) spectrometer. We report the very complementary analysis of the [1,6] naphthyridine (a N-bearing PAH) for which we recorded the microwave spectrum at the PhLAM laboratory (Lille) and the high resolution far-infrared spectrum on the AILES beamline at synchrotron facility SOLEIL. MW spectroscopy provided highly accurate rotational constants in the ground state to perform Ground State Combinations Differences (GSCD) allowing the analysis of the two most intense FT-FIR bands in the 50-900 wn range. Moreover, during this presentation the negative value of the inertial defect in the GS of the molecule will be discussed. A. Leger, J. L. Puget, Astron. Astrophys. 137, L5-L8 (1984) L. J. Allamandola et al. Astrophys. J. 290, L25-L28 (1985). Z. Kisiel et al. J. Mol. Spectrosc. 217, 115 (2003) S. Thorwirth et al. Astrophys. J. 662, 1309 (2007) D. McNaughton et al. J. Chem. Phys. 124, 154305 (2011). S. Albert et al. Faraday Discuss. 150, 71-99 (2011) B. E. Brumfield et al. Phys. Chem. Lett. 3, 1985-1988 (2012) O. Pirali et al. Phys. Chem. Chem. Phys. 15, 10141 (2013).

  18. Synthetic vision helicopter flights using high resolution LIDAR terrain data

    Sindlinger, A.; Meuter, M.; Barraci, N.; Güttler, M.; Klingauf, U.; Schiefele, J.; Howland, D.

    2006-05-01

    Helicopters are widely used for operations close to terrain such as rescue missions; therefore all-weather capabilities are highly desired. To minimize or even avoid the risk of collision with terrain and obstacles, Synthetic Vision Systems (SVS) could be used to increase situational awareness. In order to demonstrate this, helicopter flights have been performed in the area of Zurich, Switzerland A major component of an SVS is the three-dimensional (3D) depiction of terrain data, usually presented on the primary flight display (PFD). The degree of usability in low level flight applications is a function of the terrain data quality. Today's most precise, large scale terrain data are derived from airborne laser scanning technologies such as LIDAR (light detection and ranging). A LIDAR dataset provided by Swissphoto AG, Zurich with a resolution of 1m was used. The depiction of high resolution terrain data consisting of 1 million elevation posts per square kilometer on a laptop in an appropriate area around the helicopter is challenging. To facilitate the depiction of the high resolution terrain data, it was triangulated applying a 1.5m error margin making it possible to depict an area of 5x5 square kilometer around the helicopter. To position the camera correctly in the virtual scene the SVS had to be supplied with accurate navigation data. Highly flexible and portable measurement equipment which easily could be used in most aircrafts was designed. Demonstration flights were successfully executed in September, October 2005 in the Swiss Alps departing from Zurich.

  19. High-heat tank safety issue resolution program plan

    The purpose of this program plan is to provide a guide for selecting corrective actions that will mitigate and/or remediate the high-heat waste tank safety issue for single-shell tank (SST) 241-C-106. This program plan also outlines the logic for selecting approaches and tasks to mitigate and resolve the high-heat safety issue. The identified safety issue for high-heat tank 241-C-106 involves the potential release of nuclear waste to the environment as the result of heat-induced structural damage to the tank's concrete, if forced cooling is interrupted for extended periods. Currently, forced ventilation with added water to promote thermal conductivity and evaporation cooling is used to cool the waste. At this time, the only viable solution identified to resolve this safety issue is the removal of heat generating waste in the tank. This solution is being aggressively pursued as the permanent solution to this safety issue and also to support the present waste retrieval plan. Tank 241-C-106 has been selected as the first SST for retrieval. The program plan has three parts. The first part establishes program objectives and defines safety issues, drivers, and resolution criteria and strategy. The second part evaluates the high-heat safety issue and its mitigation and remediation methods and alternatives according to resolution logic. The third part identifies major tasks and alternatives for mitigation and resolution of the safety issue. Selected tasks and best-estimate schedules are also summarized in the program plan

  20. High Resolution, High Capacity, Spatial Specificity in Perceptual Learning

    Le Dantec, Christophe C.; Seitz, Aaron R.

    2012-01-01

    Research of perceptual learning has received significant interest due to findings that training on perceptual tasks can yield learning effects that are specific to the stimulus features of that task. However, recent studies have demonstrated that while training a single stimulus at a single location can yield a high-degree of stimulus specificity, training multiple features, or at multiple locations can reveal a broad transfer of learning to untrained features or stimulus locations. We devise...

  1. Massive Black Hole Recoil in High Resolution Hosts

    Guedes, Javiera; Diemand, Jürg; Zemp, Marcel; Kuhlen, Michael; Madau, Piero; Mayer, Lucio; Stadel, Joachim

    2008-01-01

    The final inspiral and coalescence of a black hole binary can produce highly beamed gravitational wave radiation. To conserve linear momentum, the black hole remnant can recoil with "kick" velocity as high as 4000 km/s. We present two sets of full N-body simulations of recoiling massive black holes (MBH) in high-resolution, non-axisymmetric potentials. The host to the first set of simulations is the main halo of the Via Lactea I simulation (Diemand et al. 2007). The nature of the resulting or...

  2. Mathematical analysis of the high-resolution reciprocal space map

    A reciprocal space map recorded by means of a high-resolution diffractometer is a function of two angular variables: ω and 2θ defined as angular position of the studied crystal and position of an analyser, respectively. For comparative investigations of different samples the inter-planar spacing distribution function and the lattice reflecting plane orientation distribution function are more useful. In this paper we present the integral equations, which allow one to obtain these functions through the integration of the reciprocal space map matrix. An example of the mathematical analysis of the reciprocal space map for GaAs single crystal recorded by means of a Philips MRD high-resolution diffractometer is described and well-defined analytical formulae for the apparatus functions are given

  3. Spaceborne laser instruments for high-resolution mapping

    Yu, Anthony W.; Krainak, Michael A.; Harding, David J.; Abshire, James B.; Sun, Xiaoli; Valett, Susan; Cavanaugh, John; Ramos-Izquierdo, Luis

    2010-02-01

    We discuss past, present and future spaceborne laser instruments for high-resolution mapping of Earth and planetary surfaces. Previous spaceborne-laser-altimeters projected and imaged a single laser spot for surface-height measurements. In contrast, the recent Lunar Orbiter Laser Altimeter (LOLA) instrument on the Lunar Reconnaissance Orbiter (LRO) uses a non-scanning multi-beam system for surface topography mapping. The multi-beam instrument facilitates surface slope measurement and reduces the time-to-completion for global high-resolution topographic mapping. We discuss our first-year progress on a three-year swath-mapping laser-altimetry Instrument Incubator Program (IIP) funded by the NASA Earth Science Technology Office (ESTO). Our IIP is a technology development program supporting the LIdar Surface Topography (LIST) space-flight mission that is a third-tier mission as recommended by the National Research Council (NRC) for NASA's Earth Science programs.

  4. European emission data with high temporal and spatial resolution

    The estimation of acidic deposition strongly depends on the availability of accurate emission data. The atmospheric models that calculate concentrations and deposition of pollutants need data in a high temporal resolution (e.g. daily, 6-hourly or even hourly data). However, although some progress has been achieved concerning annual emission data for Europe (e.g. CORINAIR 90), only very little information is available about the temporal variation of these emissions during a year. Therefore, within the EUROTRAC-GENEMIS project special emphasis was laid on the development of methods to generate emissions with a high temporal and spatial resolution. As results the temporal and spatial distribution of SO2 and NOx emissions are shown. The results indicate that the emissions vary considerably over time and that the use of simple patterns for the temporal disaggregation is not sufficient for modelling and assessment of acidic deposition. 8 refs., 4 figs., 1 tab

  5. Information retrieval methods for high resolution γ-ray spectra

    A program based on MATLAB 7.0 platform was developed to locate characteristic peak position and calculate net area of characteristic peak. The formula for the calculation of relative standard deviation of net peak area by Sterlinski's method was found excellent in searching single peaks and resolving overlapping peaks in high resolution gamma-ray spectrum. Gaussian function fitting method using Levenberg-Marquardt algorithm was applied to calculate net area of peaks. A standard test spectrum supplied by the IAEA in 1995 was analyzed by the program and another two widely used commercial software. The analysis results show the program was superior to the latter two in searching single peaks and resolving overlapping peaks. The optimized fitting indexes are found between 0.962 and 0.996, which shows that the program adopted is feasible and accurate for extracting the net peak area in high resolution gamma-ray spectra. (authors)

  6. High resolution scanning electron microscopy of cells using dielectrophoresis.

    Shi-Yang Tang

    Full Text Available Ultrastructural analysis of cells can reveal valuable information about their morphological, physiological, and biochemical characteristics. Scanning electron microscopy (SEM has been widely used to provide high-resolution images from the surface of biological samples. However, samples need to be dehydrated and coated with conductive materials for SEM imaging. Besides, immobilizing non-adherent cells during processing and analysis is challenging and requires complex fixation protocols. In this work, we developed a novel dielectrophoresis based microfluidic platform for interfacing non-adherent cells with high-resolution SEM at low vacuum mode. The system enables rapid immobilization and dehydration of samples without deposition of chemical residues over the cell surface. Moreover, it enables the on-chip chemical stimulation and fixation of immobilized cells with minimum dislodgement. These advantages were demonstrated for comparing the morphological changes of non-budding and budding yeast cells following Lyticase treatment.

  7. High resolution imaging systems for inertial confinement fusion experiments

    The path to successful inertial confinement fusion (ICF) requires to observe and control the micro balloon deformations. This will be achieved using X-ray microscope among other diagnostics. A high resolution, high energy X-ray microscope involving state-of-the-art toroidal mirrors and multilayer coatings is described. Years of experiments and experience have led to a small-scale X-ray plasma imager that proves the feasibility of all the features required for a LMJ diagnostic: spatial resolution of 5 mu m, broad bandwidth, millimetric field of view (FOV). Using the feed back given by this diagnostic, a prototype for the Laser MegaJoule (LMJ) experiments has been designed. The experimental results of the first diagnostic and the concepts of the second are discussed. (authors)

  8. Pulmonary lymphomas: high-resolution computed tomography and anatomopathological correlation

    This paper describes the high-resolution computed tomography and anatomopathological findings of pulmonary lymphomas. We studied the chest high-resolution computed tomographs and histopathological data of 10 patients with biopsy-proven non-Hodgkin's or Hodgkin's disease. The most common radiologic findings in this series were areas of consolidation with air-bronchogram (n = 8). Others findings included multiple pulmonary nodules (n = 4), thickening of bronchovascular bundles (n =3) and foci of ground-glass attenuation (n =2). The present series results are consistent with the current available literature on radiographic appearance of the disease. The pathological correspondence of the areas of air space consolidation was alveolar filling by neoplastic cells, the thickening of bronchovascular bundles was secondary to lymphomatous cells infiltrates, and the areas of ground-glass attenuation corresponded to alveolar septal infiltration by these cells. (author)

  9. High resolution reservoir geological modelling using outcrop information

    Zhang Changmin; Lin Kexiang; Liu Huaibo [Jianghan Petroleum Institute, Hubei (China)] [and others

    1997-08-01

    This is China`s first case study of high resolution reservoir geological modelling using outcrop information. The key of the modelling process is to build a prototype model and using the model as a geological knowledge bank. Outcrop information used in geological modelling including seven aspects: (1) Determining the reservoir framework pattern by sedimentary depositional system and facies analysis; (2) Horizontal correlation based on the lower and higher stand duration of the paleo-lake level; (3) Determining the model`s direction based on the paleocurrent statistics; (4) Estimating the sandbody communication by photomosaic and profiles; (6) Estimating reservoir properties distribution within sandbody by lithofacies analysis; and (7) Building the reservoir model in sandbody scale by architectural element analysis and 3-D sampling. A high resolution reservoir geological model of Youshashan oil field has been built by using this method.

  10. High resolution spectroscopy in solids by nuclear magnetic resonance

    The nuclear magnetic resonance (NMR) techniques for High Resolution Spectroscopy in Solids are described. Also the construction project of a partially home made spectrometer and its applications in the characterization of solid samples are shown in detail. The high resolution spectrometer used is implemented with the double resonance multiple pulses sequences and magic angle spinning (MAS) and can be used with solid and liquid samples. The maximum spinning frequency for the MAS experiment is in excess of 5 Khz, the double resonance sequences can be performed with any type of nucleus, in the variable temperature operating range with nitrogen gas: -1200 C to +1600 C, and is fully controlled by a Macintosh IIci microcomputer. (author)

  11. Precision cosmology with time delay lenses: high resolution imaging requirements

    Meng, Xiao-Lei; Agnello, Adriano; Auger, Matthew W; Liao, Kai; Marshall, Philip J

    2015-01-01

    Lens time delays are a powerful probe of cosmology, provided that the gravitational potential of the main deflector can be modeled with sufficient precision. Recent work has shown that this can be achieved by detailed modeling of the host galaxies of lensed quasars, which appear as "Einstein Rings" in high resolution images. We carry out a systematic exploration of the high resolution imaging required to exploit the thousands of lensed quasars that will be discovered by current and upcoming surveys with the next decade. Specifically, we simulate realistic lens systems as imaged by the Hubble Space Telescope (HST), James Webb Space Telescope (JWST), and ground based adaptive optics images taken with Keck or the Thirty Meter Telescope (TMT). We compare the performance of these pointed observations with that of images taken by the Euclid (VIS), Wide-Field Infrared Survey Telescope (WFIRST) and Large Synoptic Survey Telescope (LSST) surveys. We use as our metric the precision with which the slope $\\gamma'$ of the...

  12. Dynamical downscaling inter-comparison for high resolution climate reconstruction

    Ferreira, J.; Rocha, A.; Castanheira, J. M.; Carvalho, A. C.

    2012-04-01

    In the scope of the project: "High-resolution Rainfall EroSivity analysis and fORecasTing - RESORT", an evaluation of various methods of dynamic downscaling is presented. The methods evaluated range from the classic method of nesting a regional model results in a global model, in this case the ECMWF reanalysis, to more recently proposed methods, which consist in using Newtonian relaxation methods in order to nudge the results of the regional model to the reanalysis. The method with better results involves using a system of variational data assimilation to incorporate observational data with results from the regional model. The climatology of a simulation of 5 years using this method is tested against observations on mainland Portugal and the ocean in the area of the Portuguese Continental Shelf, which shows that the method developed is suitable for the reconstruction of high resolution climate over continental Portugal.

  13. Virtual microscope interface to high resolution histological images

    Feit, Josef; Matyska, Luděk; Ulman, Vladimír; HEJTMÁNEK, Lukáš; Jedličková, Hana; Ježová, Marta; Moulis, Mojmír; Feitová, Věra

    2008-01-01

    The Hypertext atlas of Dermatopathology, the Atlas of Fetal and Neonatal Pathology and Hypertext atlas of Pathology (this one in Czech only) are available at . These atlases offer many clinical, macroscopic and microscopic images, together with short introductory texts. Most of the images are annotated and arrows pointing to the important parts of the image can be activated. The Virtual Microscope interface is used for the access to the histological images obtained in high resolution using au...

  14. A High Resolution Grammatical Model for Face Representation and Sketching

    Xu, Zijian; Chen, Hong; Zhu, Song-Chun

    2005-01-01

    In this paper we present a generative, high resolution face representation which extends the well- known active appearance model (AAM)[5], [6], [7] with two additional layers. (i) One layer refines the global AAM (PCA) model with a dictionary of learned face components to account for the shape and intensity variabilities of eyes, eyebrows, nose and mouth. (ii) The other layer divides the face skin into 9 zones with a learned dictionary of sketch primitives to represent skin marks and wrin...

  15. A High Resolution Grammatical Model for Face Representation and Sketching

    Zijian Xu; Hong Chen; Song-Chun Zhu

    2011-01-01

    In this paper we present a generative, high resolution face representation which extends the wellknown active appearance model (AAM)[5], [6], [7] with two additional layers. (i) One layer refines the global AAM (PCA) model with a dictionary of learned face components to account for the shape and intensity variabilities of eyes, eyebrows, nose and mouth. (ii) The other layer divides the face skin into 9 zones with a learned dictionary of sketch primitives to represent skin marks and wrinkles. ...

  16. Yeast expression proteomics by high-resolution mass spectrometry

    Walther, Tobias C; Olsen, Jesper Velgaard; Mann, Matthias

    2010-01-01

    -translational controls contribute majorly to regulation of protein abundance, for example in heat shock stress response. The development of new sample preparation methods, high-resolution mass spectrometry and novel bioinfomatic tools close this gap and allow the global quantitation of the yeast proteome under different...... conditions. Here, we provide background information on proteomics by mass-spectrometry and describe the practice of a comprehensive yeast proteome analysis....

  17. Acute pulmonary injury: high-resolution CT and histopathological spectrum

    Obadina, E T; Torrealba, J M; Kanne, J P

    2013-01-01

    Acute lung injury usually causes hypoxaemic respiratory failure and acute respiratory distress syndrome (ARDS). Although diffuse alveolar damage is the hallmark of ARDS, other histopathological patterns of injury, such as acute and fibrinoid organising pneumonia, can be associated with acute respiratory failure. Acute eosinophilic pneumonia can also cause acute hypoxaemic respiratory failure and mimic ARDS. This pictorial essay reviews the high-resolution CT findings of acute lung injury and ...

  18. Precision crystal alignment for high-resolution electron microscope imaging

    One of the more difficult tasks involved in obtaining quality high-resolution electron micrographs is the precise alignment of a specimen into the required zone. The current accepted procedure, which involves changing to diffraction mode and searching for symmetric point diffraction pattern, is insensitive to small amounts of misalignment and at best qualitative. On-line analysis of the fourier space representation of the image, both for determining and correcting crystal tilt, is investigated. 8 refs., 42 figs

  19. High resolution ultrasound characterization of soft tissue masses in children

    Forty-two soft tissue masses in infants and children were examined with high resolution ultrasonography. Sonography was diagnostically specific in 17/42 (40%), useful but not diagnostic in 24/42 (58%), and misleading in 1/42 (2%) of soft tissue masses. Lesions with diagnostic sonographic features included cystic hygroma, fibromatosis colli, lymphadenopathy with abscess formation, and one case of osteomyelitis. (orig.)

  20. Towards regional fusion for high-resolution palmprint recognition

    Wang, Ruifang; Ramos, Daniel; Krishnamoorthy, Ram Prasad; Fiérrez, Julián

    2013-01-01

    Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. R. Wang, D. Ramos, J. Fiérrez, R. P. Krish, "Towards Regional Fusion for High-Resolution Palmprint Recognition" in 26th Confer...

  1. Tuberculous otitis media: findings on high-resolution CT

    We describe two cases of tuberculous otitis media studied with high-resolution computed tomography (CT). Findings included extensive soft tissue densities with fluid levels in the tympanic cavity, the antrum, the mastoid and petrous air cells. Multifocal bony erosions and reactive bone sclerosis were seen as well. CT proved valuable for planning therapy by accurately displaying the involvement of the various structures of the middle and inner ear. However, the specific nature of the disease could only be presumed. (orig.)

  2. High Resolution Inventory of Renewable Electricity Generation Potentials in Europe

    Scholz, Yvonne; Hoyer-Klick, Carsten; Schillings, Christoph; Gehrung, Julia; Krewitt, Wolfram

    2006-01-01

    Efficient integration of fluctuating renewable energy resources into electricity supply systems requires information about temporal and spatial availability of all renewable energy sources. Aiming at the provision of such information, high spatial and temporal resolution inventories of solar, wind, biomass, water and geothermal electricity generation potentials in Europe are developed at the German Aerospace Center using a GIS (geographic information system). The potential inventories ar...

  3. High-Resolution Wind Measurements for Offshore Wind Energy Development

    Nghiem, Son V.; Neumann, Gregory

    2011-01-01

    A mathematical transform, called the Rosette Transform, together with a new method, called the Dense Sampling Method, have been developed. The Rosette Transform is invented to apply to both the mean part and the fluctuating part of a targeted radar signature using the Dense Sampling Method to construct the data in a high-resolution grid at 1-km posting for wind measurements over water surfaces such as oceans or lakes.

  4. Position-Independent Interaction for Large High-Resolution Displays

    König, Werner A.; Bieg, Hans-Joachim; Schmidt, Toni; Reiterer, Harald

    2007-01-01

    Since large, high-resolution displays (LHRD) are capable of visualizing a large amount of very detailed information, users have to move around in front of these displays to gain either in-depth knowledge or an overview. However, conventional input devices such as mouse and keyboard restrict users mobility by requiring a stable surface on which to operate. We present a flexible and intuitive interaction technique based on an infrared laserpointer, a technique that allows identical use from any...

  5. A compact high-resolution X-ray powder diffractometer

    Fewster, Paul F.; Trout, David R. D.

    2013-01-01

    A new powder diffractometer operating in transmission mode is described. It can work as a rapid very compact instrument or as a high-resolution instrument, and the sample preparation is simplified. The incident beam optics create pure Cu Kα1 radiation, giving rise to peak widths of ∼0.1° in 2θ in compact form with a sample-to-detector minimum radius of 55 mm, reducing to peak widths of

  6. Sequential High-Resolution Direction Finding From Higher Order Statistics

    Birot, Gwénaël; Albera, Laurent; Chevalier, Pascal

    2010-01-01

    12 pages International audience The classical higher order MUSIC-like methods based on a simultaneous search for all Directions Of Arrival (DOA's) show i) a capacity for processing underdetermined mixtures of sources, ii) a high robustness with respect to both a Gaussian noise with unknown spatial coherence and modeling errors, and iii) a better resolution than algorithms based on second order statistics. However, these methods have some limits: for a finite number of samples, they show...

  7. Planet Rendering Using Online High-Resolution Datasets

    Östergaard, Johan

    2008-01-01

    A large amount of image datasets are publicly available online through the web map service standard. The contents of the datasets span from satellite imagery of the earth and other planets of our solar system to various scientific data. This thesis presents an implementation of a planet renderer streaming high resolution image and height data from online datasets. The planet renderer uses a level of detail technique based on nodes connected by a quad tree data structure. The level of detail i...

  8. High-resolution spectroscopy of gases for industrial applications

    Fateev, Alexander; Clausen, Sønnik

    2012-01-01

    High-resolution spectroscopy of gases is a powerful technique which has various fundamental and practical applications: in situ simultaneous measurements of gas temperature and gas composition, radiative transfer modeling, validation of existing and developing of new databases and etc. Existing databases (e.g. HITRAN, HITEMP or CDSD) can normally be used for absorption spectra calculations at limited temperature/pressure ranges. Therefore experimental measurements of absorption/transmission s...

  9. A high resolution cavity BPM for the CLIC Test Facility

    Chritin, N.; Schmickler, H.; Soby, L.; /CERN; Lunin, A.; Solyak, N.; Wendt, M.; Yakovlev, V.; /Fermilab

    2010-08-01

    In frame of the development of a high resolution BPM system for the CLIC Main Linac we present the design of a cavity BPM prototype. It consists of a waveguide loaded dipole mode resonator and a monopole mode reference cavity, both operating at 15 GHz, to be compatible with the bunch frequencies at the CLIC Test Facility. Requirements, design concept, numerical analysis, and practical considerations are discussed.

  10. An RPC-PET prototype with high spatial resolution

    Blanco, A.; Carolino, N.; Correia, C. M. B. A.; Marques, R. Ferreira; P. Fonte(LIP-Laboratório de Instrumentação e Física Experimental de Partículas, Portugal); González-Díaz, D.; Lindote, A.; Lopes, M.I.; Macedo, M. P.; Policarpo, A.

    2004-01-01

    A small positron emission tomography system, based on the timing RPC technology has been built and tested. This first prototype is aimed at validating the expectations, derived from simulations, of a very high spatial resolution, which could be of value for the imaging of small animals. The system is composed of two counting heads, able to measure the photon interaction point in two dimensions, the transaxial dimension and the Depth of Interaction. Each head is composed of 16 independent stac...

  11. High resolution field imaging with atomic vapor cells

    Horsley, Andrew

    2015-01-01

    In this thesis, I report on the development of imaging techniques in atomic vapor cells. This is a relatively unexplored area, despite the ubiquitous use of imaging in experiments with ultracold atoms. Our main focus is in high resolution imaging of microwave near fields, for which there is currently no satisfactory established technique. We detect microwave fields through Rabi oscillations driven by the microwave on atomic hyperfine transitions. The technique can be easily modified to also i...

  12. Aerosol classification by airborne high spectral resolution lidar observations

    S. Groß; Esselborn, M.; Weinzierl, B.; M. Wirth; Fix, A.; Petzold, A

    2012-01-01

    During four aircraft field experiments with the DLR research aircraft Falcon in 1998 (LACE), 2006 (SAMUM-1) and 2008 (SAMUM-2 and EUCAARI), airborne High Spectral Resolution Lidar (HSRL) and in situ measurements of aerosol microphysical and optical properties were performed. Altogether, the properties of six different aerosol types and aerosol mixtures – Saharan mineral dust, Saharan dust mixtures, Canadian biomass burning aerosol, African biomass burning aerosol, anthropogenic polluti...

  13. Progress Toward A Very High Angular Resolution Imaging Spectrometer (VERIS)

    Korendyke, Clarence M.; Vourlidas, A.; Landi, E.; Seely, J.; Klimchuck, J.

    2007-07-01

    Recent imaging at arcsecond (TRACE) and sub-arcsecond (VAULT) spatial resolution clearly show that structures with fine spatial scales play a key role in the physics of the upper solar atmosphere. Both theoretical and observational considerations point to the importance of small spatial scales, impulsive energy release, strong dynamics, and extreme plasma nonuniformity. Fundamental questions regarding the nature, structure, properties and dynamics of loops and filamentary structures in the upper atmosphere have been raised. To address these questions, we are developing a next generation, VEry high angular Resolution Imaging Spectrometer (VERIS) as a sounding rocket instrument. VERIS will obtain the necessary high spatial resolution, high fidelity measurements of plasma temperatures, densities and velocities. With broad simultaneous temperature coverage, the VERIS observations will directly address unresolved issues relating to interconnections of various temperature solar plasmas. VERIS will provide the first ever subarcsecond spectra of transition region and coronal structures. It will do so with a sufficient spectral resolution of to allow centroided Doppler velocity determinations to better than 3 km/s. VERIS uses a novel two element, normal incidence optical design with highly reflective EUV coatings to access a spectral range with broad temperature coverage (0.03-15 MK) and density-sensitive line ratios. Finally, in addition to the spectra, VERIS will simultaneously obtain spectrally pure slot images (10x150 arcsec) in the +/-1 grating orders, which can be combined to make instantaneous line-of-sight velocity maps with 8km/s accuracy over an unprecedented field of view. The VERIS program is beginning the second year of its three year development cycle. All design activities and reviews are complete. Fabrication of all major components has begun. Brassboard electronics cards have been fabricated, assembled and tested. The paper presents the essential scientific

  14. On high resolution finite volume shock capturing schemes

    Causon, D. M.; Clarke, N.

    Conservative shock-capturing methods for the unsteady Euler equations are reviewed, and it is shown that the concepts of entropy satisfaction and total variation diminution can be applied to well known classical schemes. For an associated scheme to be efficient in applications, it is necessary that it be constructed with economy of implementation in mind, and that it be able to capture strong shock waves with high resolution. A scheme which is efficient in both respects is described.

  15. On high-resolution finite volume shock capturing schemes

    Causon, D. M.; Clarke, N.

    1990-07-01

    Conservative, shock capturing methods for the unsteady Euler equations are reviewed and it is shown that the concepts of entropy satisfaction and total variation diminution can be applied to well-known classical schemes. For an associated scheme to be efficient in applications, it is necessary that it be constructed with economy of implementation in mind, and that it be able to capture strong shock waves with high resolution. We describe a scheme which is efficient in both respects.

  16. High Resolution Aircraft Scanner Mapping of Geothermal and Volcanic Areas

    Mongillo, M.A.; Cochrane, G.R.; Wood, C.P.; Shibata, Y.

    1995-01-01

    High spectral resolution GEOSCAN Mkll multispectral aircraft scanner imagery has been acquired, at 3-6 m spatial resolutions, over much of the Taupo Volcanic Zone as part of continuing investigations aimed at developing remote sensing techniques for exploring and mapping geothermal and volcanic areas. This study examined the 24-band: visible, near-IR (NIR), mid-IR (MIR) and thermal-IR (TIR) imagery acquired over Waiotapu geothermal area (3 m spatial resolution) and White Island volcano (6 m resolution). Results show that color composite images composed of visible and NIR wavelengths that correspond to color infrared (CIR) photographic wavelengths can be useful for distinguishing among bare ground, water and vegetation features and, in certain cases, for mapping various vegetation types. However, combinations which include an MIR band ({approx} 2.2 {micro}m) with either visible and NIR bands, or two NIR bands, are the most powerful for mapping vegetation types, water bodies, and bare and hydrothermally altered ground. Combinations incorporating a daytime TIR band with NIR and MIR bands are also valuable for locating anomalously hot features and distinguishing among different types of surface hydrothermal alteration.

  17. High-resolution MRI for Primary anal fistulas

    Objective: To evaluate the accuracy and clinical value of preoperative high-resolution magnetic resonance (MR) imaging with a phased-army coil for the detection of anal fistulas. Methods: A total of 20 patients with surgically proved anal fistulas underwent preoperative MR imaging with phased-array coil at 1.5 T MR unit. The imaging protocol included high-resolution T2-weighted turbo spin echo sequence acquisition at axial, sagittal and coronal planes and axial T2-weighted sequence with fat suppression. Results: Twenty patients were found to have 27 fistulas, 24 internal openings, 28 external openings, and 10 perianal abcesses. The sensitivity and specificity for detecting primary fistula tracks, abscesses and internal openings were 92.6% (25/27) and 92.3% (12/13), 100.0% (10/10) and 96.3% (26/27), 91.7% (22/24) and 85.7% (12/14), respectively. Conclusion: High-resolution Mil imaging is a very accurate preoperative technique for evaluating the classification of fistula-in-ano, the course of primary tracks and the presence of abscesses, thus providing important information for proper surgical treatment. (authors)

  18. Machine Learning Based Road Detection from High Resolution Imagery

    Lv, Ye; Wang, Guofeng; Hu, Xiangyun

    2016-06-01

    At present, remote sensing technology is the best weapon to get information from the earth surface, and it is very useful in geo- information updating and related applications. Extracting road from remote sensing images is one of the biggest demand of rapid city development, therefore, it becomes a hot issue. Roads in high-resolution images are more complex, patterns of roads vary a lot, which becomes obstacles for road extraction. In this paper, a machine learning based strategy is presented. The strategy overall uses the geometry features, radiation features, topology features and texture features. In high resolution remote sensing images, the images cover a great scale of landscape, thus, the speed of extracting roads is slow. So, roads' ROIs are firstly detected by using Houghline detection and buffering method to narrow down the detecting area. As roads in high resolution images are normally in ribbon shape, mean-shift and watershed segmentation methods are used to extract road segments. Then, Real Adaboost supervised machine learning algorithm is used to pick out segments that contain roads' pattern. At last, geometric shape analysis and morphology methods are used to prune and restore the whole roads' area and to detect the centerline of roads.

  19. High frequency resolution terahertz time-domain spectroscopy

    Sangala, Bagvanth Reddy

    2013-12-01

    A new method for the high frequency resolution terahertz time-domain spectroscopy is developed based on the characteristic matrix method. This method is useful for studying planar samples or stack of planar samples. The terahertz radiation was generated by optical rectification in a ZnTe crystal and detected by another ZnTe crystal via electro-optic sampling method. In this new characteristic matrix based method, the spectra of the sample and reference waveforms will be modeled by using characteristic matrices. We applied this new method to measure the optical constants of air. The terahertz transmission through the layered systems air-Teflon-air-Quartz-air and Nitrogen gas-Teflon-Nitrogen gas-Quartz-Nitrogen gas was modeled by the characteristic matrix method. A transmission coefficient is derived from these models which was optimized to fit the experimental transmission coefficient to extract the optical constants of air. The optimization of an error function involving the experimental complex transmission coefficient and the theoretical transmission coefficient was performed using patternsearch algorithm of MATLAB. Since this method takes account of the echo waveforms due to reflections in the layered samples, this method allows analysis of longer time-domain waveforms giving rise to very high frequency resolution in the frequency-domain. We have presented the high frequency resolution terahertz time-domain spectroscopy of air and compared the results with the literature values. We have also fitted the complex susceptibility of air to the Lorentzian and Gaussian functions to extract the linewidths.

  20. Pneumonia: high-resolution CT findings in 114 patients

    The objective of the present study was to assess the high-resolution CT appearances of different types of pneumonia. The high-resolution CT scans obtained in 114 patients (58 immunocompetent, 59 immunocompromised) with bacterial, Mycoplasma pneumoniae, viral, fungal, and Pneumocystis carinii pneumonias were analyzed retrospectively by two independent observers for presence, pattern, and distribution of abnormalities. Areas of air-space consolidation were not detected in patients with viral pneumonia and were less frequently seen in patients with Pneumocystis carinii pneumonia (2 of 22 patients, 9%) than in bacterial (30 of 35, 85%), Mycoplasma pneumoniae (22 of 28, 79%), and fungal pneumonias (15 of 20, 75%; p<0.01). There was no significant difference in the prevalence or distribution of consolidation between bacterial, Mycoplasma pneumoniae, and fungal pneumonias. Extensive symmetric bilateral areas of ground-glass attenuation were present in 21 of 22 (95%) patients with Pneumocystis carinii pneumonia and were not seen in other pneumonias except in association with areas of consolidation and nodules. Centrilobular nodules were present less commonly in bacterial pneumonia (6 of 35 patients, 17%) than in Mycoplasma pneumoniae (24 of 28, 96%), viral (7 of 9, 78%), or fungal (12 of 20, 92%) pneumonia (p<0.01). Except for Pneumocystis carinii pneumonia and Mycoplasma pneumoniae pneumonia, which often have a characteristic appearance, high-resolution CT is of limited value in the differential diagnosis of the various types of infective pneumonia. (orig.)

  1. High resolution, MRI-based, segmented, computerized head phantom

    Zubal, I.G.; Harrell, C.R.; Smith, E.O.; Smith, A.L.; Krischlunas, P. [Yale Univ., New Haven, CT (United States). Dept. of Diagnostic Radiology

    1999-01-01

    The authors have created a high-resolution software phantom of the human brain which is applicable to voxel-based radiation transport calculations yielding nuclear medicine simulated images and/or internal dose estimates. A software head phantom was created from 124 transverse MRI images of a healthy normal individual. The transverse T2 slices, recorded in a 256x256 matrix from a GE Signa 2 scanner, have isotropic voxel dimensions of 1.5 mm and were manually segmented by the clinical staff. Each voxel of the phantom contains one of 62 index numbers designating anatomical, neurological, and taxonomical structures. The result is stored as a 256x256x128 byte array. Internal volumes compare favorably to those described in the ICRP Reference Man. The computerized array represents a high resolution model of a typical human brain and serves as a voxel-based anthropomorphic head phantom suitable for computer-based modeling and simulation calculations. It offers an improved realism over previous mathematically described software brain phantoms, and creates a reference standard for comparing results of newly emerging voxel-based computations. Such voxel-based computations lead the way to developing diagnostic and dosimetry calculations which can utilize patient-specific diagnostic images. However, such individualized approaches lack fast, automatic segmentation schemes for routine use; therefore, the high resolution, typical head geometry gives the most realistic patient model currently available.

  2. A high-resolution record of Greenland mass balance

    McMillan, Malcolm; Leeson, Amber; Shepherd, Andrew; Briggs, Kate; Armitage, Thomas W. K.; Hogg, Anna; Kuipers Munneke, Peter; Broeke, Michiel; Noël, Brice; Berg, Willem Jan; Ligtenberg, Stefan; Horwath, Martin; Groh, Andreas; Muir, Alan; Gilbert, Lin

    2016-07-01

    We map recent Greenland Ice Sheet elevation change at high spatial (5 km) and temporal (monthly) resolution using CryoSat-2 altimetry. After correcting for the impact of changing snowpack properties associated with unprecedented surface melting in 2012, we find good agreement (3 cm/yr bias) with airborne measurements. With the aid of regional climate and firn modeling, we compute high spatial and temporal resolution records of Greenland mass evolution, which correlate (R = 0.96) with monthly satellite gravimetry and reveal glacier dynamic imbalance. During 2011-2014, Greenland mass loss averaged 269 ± 51 Gt/yr. Atmospherically driven losses were widespread, with surface melt variability driving large fluctuations in the annual mass deficit. Terminus regions of five dynamically thinning glaciers, which constitute less than 1% of Greenland's area, contributed more than 12% of the net ice loss. This high-resolution record demonstrates that mass deficits extending over small spatial and temporal scales have made a relatively large contribution to recent ice sheet imbalance.

  3. The high resolution shear wave seismic reflection technique

    This report presents the state-of-the-art of the high resolution S-wave reflection technique. Published and unpublished literature has been reviewed and discussions have been held with experts. Result is to confirm that the proposed theoretical and practical basis for identifying aquifer systems using both P- and S-wave reflections is sound. Knowledge of S-wave velocity and P-wave velocity is a powerful tool for assessing the fluid characteristics of subsurface layers. Material properties and lateral changes in material properties such as change from clay to sand, can be inferred from careful dual evaluation of P and S-wave records. The high resolution S-wave reflection technique has seen its greatest application to date as part of geotechnical studies for building foundations in the Far East. Information from this type of study has been evaluated and will be incorporated in field studies. In particular, useful information regarding S-wave sources, noise suppression and recording procedures will be incorporated within the field studies. Case histories indicate that the best type of site for demonstrating the power of the high resolution S-wave technique will be in unconsolidated soil without excessive structural complexities. More complex sites can form the basis for subsequent research after the basic principles of the technique can be established under relatively uncomplicated conditions

  4. High Spectral Resolution, High Cadence, Imaging X-ray Microcalorimeters for Solar Physics - Phase 2 Project

    National Aeronautics and Space Administration — Microcalorimeter x-ray instruments are non-dispersive, high spectral resolution, broad-band, high cadence imaging spectrometers. We have been developing these...

  5. High real-space resolution structure of materials by high-energy X-ray diffraction

    Results of high-energy synchrotrons radiation experiments are presented demonstrating the advantages of the atomic Pair Distribution Function technique in determining the structure of materials with high resolution

  6. High real-space resolution structure of materials by high-energy x-ray diffraction

    Petkov, V.; Billinge, S. J. L.; Heising, J.; Kanatzidis, M. G.; Shastri, S.; Kycia, S.

    1999-12-10

    Results of high-energy synchrotrons radiation experiments are presented demonstrating the advantages of the atomic Pair Distribution Function technique in determining the structure of materials with high resolution.

  7. Measurement of the weighted peak level for occupational exposure to gradient magnetic fields for 1.5 and 3 Tesla MRI body scanners

    The purpose of this work is to give a contribution to the construction of a comprehensive knowledge of the exposure levels to gradient magnetic fields (GMF) in terms of the weighed peak (WP), especially for 3 Tesla scanners for which there are still few works available in the literature. A new generation probe for the measurement of electromagnetic fields in the range of 1 Hz-400 kHz was used to assess the occupational exposure levels to the GMF for 1.5 and 3.0 Tesla MRI body scanners, using the method of the WP according to the International Commission on Non-Ionizing Radiation Protection (ICNIRP) approach. The probe was placed at a height of 1.1 m, close to the MRI scanners, where operators could stay during some medical procedures with particular issues. The measurements were performed for a set of typical acquisition sequences for body (liver) and head exams. The measured values of WP were in compliance with ICNIRP 2010 reference levels for occupational exposures. (authors)

  8. Measurement of the weighted peak level for occupational exposure to gradient magnetic fields for 1.5 and 3 Tesla MRI body scanners.

    Bonutti, F; Tecchio, M; Maieron, M; Trevisan, D; Negro, C; Calligaris, F

    2016-03-01

    The purpose of this work is to give a contribution to the construction of a comprehensive knowledge of the exposure levels to gradient magnetic fields (GMF) in terms of the weighed peak (WP), especially for 3 Tesla scanners for which there are still few works available in the literature. A new generation probe for the measurement of electromagnetic fields in the range of 1 Hz-400 kHz was used to assess the occupational exposure levels to the GMF for 1.5 and 3.0 Tesla MRI body scanners, using the method of the WP according to the International Commission on Non-Ionizing Radiation Protection (ICNIRP) approach. The probe was placed at a height of 1.1 m, close to the MRI scanners, where operators could stay during some medical procedures with particular issues. The measurements were performed for a set of typical acquisition sequences for body (liver) and head exams. The measured values of WP were in compliance with ICNIRP 2010 reference levels for occupational exposures. PMID:25987585

  9. High resolution modeling of a small urban catchment

    Skouri-Plakali, Ilektra; Ichiba, Abdellah; Gires, Auguste; Tchiguirinskaia, Ioulia; Schertzer, Daniel

    2016-04-01

    Flooding is one of the most complex issues that urban environments have to deal with. In France, flooding remains the first natural risk with 72% of decrees state of natural disaster issued between October 1982 and mid-November 2014. Flooding is a result of meteorological extremes that are usually aggravated by the hydrological behavior of urban catchments and human factors. The continuing urbanization process is indeed changing the whole urban water cycle by limiting the infiltration and promoting runoff. Urban environments are very complex systems due to their extreme variability, the interference between human activities and natural processes but also the effect of the ongoing urbanization process that changes the landscape and hardly influences their hydrologic behavior. Moreover, many recent works highlight the need to simulate all urban water processes at their specific temporal and spatial scales. However, considering urban catchments heterogeneity still challenging for urban hydrology, even after advances noticed in term of high-resolution data collection and computational resources. This issue is more to be related to the architecture of urban models being used and how far these models are ready to take into account the extreme variability of urban catchments. In this work, high spatio-temporal resolution modeling is performed for a small and well-equipped urban catchment. The aim of this work is to identify urban modeling needs in terms of spatial and temporal resolution especially for a very small urban area (3.7 ha urban catchment located in the Perreux-sur-Marne city at the southeast of Paris) MultiHydro model was selected to carry out this work, it is a physical based and fully distributed model that interacts four existing modules each of them representing a portion of the water cycle in urban environments. MultiHydro was implemented at 10m, 5m and 2m resolution. Simulations were performed at different spatio-temporal resolutions and analyzed with

  10. High resolution detection systems for interdiction of nuclear material trafficking

    The interdiction of nuclear materials during illegal transportation requires both detection of radiation and identification of radionuclides in order to distinguish among the various categories of nuclides and their implied threat. Interdiction regimes, based upon available technologies, were developed rapidly after the tragic events of 9-11. In general, a low resolution or 'no-resolution' portal monitor, based on scintillators, provides initial detection, followed by a search and identify phase. A major problem with these systems is that of innocent alarms or false positives, where, for example, a naturally radioactive substance triggers a portal monitor. An equally severe problem is false negatives whereby nuclear material can be masked or hidden in an otherwise innocent shipment. Recent experience has shown that in general, 90% of innocent alarms at airports are due to medical isotopes in the bodies of travellers, while in cargo freight, the major problem is caused by natural emitters. Ultimately reliable nuclide identification must be made. For logistical reasons, such as to preserve traffic flows, it is necessary to make a positive identification in as short a time as possible. Germanium detectors (HPGe) have been the choice for high-resolution, gamma-ray spectroscopy for many years because of their high resolution and efficiency or stopping power especially at energies above 2 MeV. These detectors are considerably less vulnerable to the problems of false negatives and positives, and are able to identify nuclides with a high degree of certainty. A new portable nuclide identifier based upon the latest HPGe technology will be described

  11. High resolution seismic reflection profiling at Aberdeen Proving Grounds, Maryland

    The effectiveness of shallow high resolution seismic reflection (i.e., resolution potential) to image geologic interfaces between about 70 and 750 ft at the Aberdeen Proving Grounds, Maryland (APG), appears to vary locally with the geometric complexity of the unconsolidated sediments that overlay crystalline bedrock. The bedrock surface (which represents the primary geologic target of this study) was imaged at each of three test areas on walkaway noise tests and CDP (common depth point) stacked data. Proven high resolution techniques were used to design and acquire data on this survey. Feasibility of the technique and minimum acquisition requirements were determined through evaluation and correlation of walkaway noise tests, CDP survey lines, and a downhole velocity check shot survey. Data processing and analysis revealed several critical attributes of shallow seismic data from APG that need careful consideration and compensation on reflection data sets. This survey determined: (1) the feasibility of the technique, (2) the resolution potential (both horizontal and vertical) of the technique, (3) the optimum source for this site, (4) the optimum acquisition geometries, (5) general processing flow, and (6) a basic idea of the acoustic variability across this site. Source testing involved an accelerated weight drop, land air gun, downhole black powder charge, sledge hammer/plate, and high frequency vibrator. Shallow seismic reflection profiles provided for a more detailed picture of the geometric complexity and variability of the distinct clay sequences (aquatards), previously inferred from drilling to be present, based on sparse drill holes and basewide conceptual models. The seismic data also reveal a clear explanation for the difficulties previously noted in correlating individual, borehole-identified sand or clay units over even short distances

  12. High spatial resolution diffusion tensor imaging and its applications

    Introduction Magnetic Resonance Imaging is at present the only imaging technique available to measure diffusion of water and metabolites in humans. It provides vital insights to brain connectivity and has proved to be an important tool in diagnosis and therapy planning in many neurological diseases such as brain tumour, ischaemia and multiple sclerosis. This project focuses on the development of a high resolution diffusion tensor imaging technique. In this thesis, the basic theory of diffusion tensor MR Imaging is presented. The technical challenges encountered during development of these techniques will be discussed, with proposed solutions. New sequences with high spatial resolution have been developed and the results are compared with the standard technique more commonly used. Overview The project aims at the development of diffusion tensor imaging techniques with a high spatial resolution. Chapter 2 will describe the basic physics of MRI, the phenomenon of diffusion and the measurement of diffusion by MRI. The basic parameters used all through the projects will be presented. In Chapter 3, a reproducibility study on DTI with the single shot EPI sequence will be conducted. The single shot DT-EPI was carried out on a stroke patient. In Chapter 4, current techniques on high spatial resolution DTI will be explored. Sequences of Interleaved EPI of two segments and EPI with Half Fourier acquisition will be developed. The sources of artefacts which contaminate most DT images will be discussed with solution proposed. Chapter 5 proposed a new selective averaging algorithm for the data acquired by the sequences of interleaved EPI. It does not require cardiac gating during data acquisition period and thus increase the speed of data collection. A new ghost free segmented EPI sequence will be presented in Chapter 6: Half-FOV EPI. The technique will be tested on a phantom in vitro as well as in two normal male volunteers in vivo. A comparison study on diffusion tensor imaging

  13. High Resolution Continuous Flow Analysis System for Polar Ice Cores

    Dallmayr, Remi; Azuma, Kumiko; Yamada, Hironobu; Kjær, Helle Astrid; Vallelonga, Paul; Azuma, Nobuhiko; Takata, Morimasa

    2014-05-01

    In the last decades, Continuous Flow Analysis (CFA) technology for ice core analyses has been developed to reconstruct the past changes of the climate system 1), 2). Compared with traditional analyses of discrete samples, a CFA system offers much faster and higher depth resolution analyses. It also generates a decontaminated sample stream without time-consuming sample processing procedure by using the inner area of an ice-core sample.. The CFA system that we have been developing is currently able to continuously measure stable water isotopes 3) and electrolytic conductivity, as well as to collect discrete samples for the both inner and outer areas with variable depth resolutions. Chemistry analyses4) and methane-gas analysis 5) are planned to be added using the continuous water stream system 5). In order to optimize the resolution of the current system with minimal sample volumes necessary for different analyses, our CFA system typically melts an ice core at 1.6 cm/min. Instead of using a wire position encoder with typical 1mm positioning resolution 6), we decided to use a high-accuracy CCD Laser displacement sensor (LKG-G505, Keyence). At the 1.6 cm/min melt rate, the positioning resolution was increased to 0.27mm. Also, the mixing volume that occurs in our open split debubbler is regulated using its weight. The overflow pumping rate is smoothly PID controlled to maintain the weight as low as possible, while keeping a safety buffer of water to avoid air bubbles downstream. To evaluate the system's depth-resolution, we will present the preliminary data of electrolytic conductivity obtained by melting 12 bags of the North Greenland Eemian Ice Drilling (NEEM) ice core. The samples correspond to different climate intervals (Greenland Stadial 21, 22, Greenland Stadial 5, Greenland Interstadial 5, Greenland Interstadial 7, Greenland Stadial 8). We will present results for the Greenland Stadial -8, whose depths and ages are between 1723.7 and 1724.8 meters, and 35.520 to

  14. High-resolution NMR studies on radiolytic reactions in polyethylene

    High-resolution NMR spectra was obtained for linear polyethylene powder irradiated by 60Co γ-rays in vacuo or in air. For the sample irradiated in vacuo, the spectra consist of two components having different line width. The narrow component was assigned to soluble molecules and the broad one to gel. When samples are irradiated in air, their spectra show no broad component. The GPC curves obtained for the samples irradiated in air shift to high elution counts (low molecular weight) upon increase of the irradiation dose. It is concluded that oxidative degradation is the predominant reaction in the sample irradiated in air

  15. High-Resolution and Animal Imaging Instrumentation and Techniques

    Belcari, Nicola; Guerra, AlbertoDel

    During the last decade we have observed a growing interest in "in vivo" imaging techniques for small animals. This is due to the necessity of studying biochemical processes at a molecular level for pharmacology, genetic, and pathology investigations. This field of research is usually called "molecular imaging."Advances in biological understanding have been accompanied by technological advances in instrumentation and techniques and image-reconstruction software, resulting in improved image quality, visibility, and interpretation. The main technological challenge is then the design of systems with high spatial resolution and high sensitivity.

  16. Live CLEM imaging to analyze nuclear structures at high resolution.

    Haraguchi, Tokuko; Osakada, Hiroko; Koujin, Takako

    2015-01-01

    Fluorescence microscopy (FM) and electron microscopy (EM) are powerful tools for observing molecular components in cells. FM can provide temporal information about cellular proteins and structures in living cells. EM provides nanometer resolution images of cellular structures in fixed cells. We have combined FM and EM to develop a new method of correlative light and electron microscopy (CLEM), called "Live CLEM." In this method, the dynamic behavior of specific molecules of interest is first observed in living cells using fluorescence microscopy (FM) and then cellular structures in the same cell are observed using electron microscopy (EM). Following image acquisition, FM and EM images are compared to enable the fluorescent images to be correlated with the high-resolution images of cellular structures obtained using EM. As this method enables analysis of dynamic events involving specific molecules of interest in the context of specific cellular structures at high resolution, it is useful for the study of nuclear structures including nuclear bodies. Here we describe Live CLEM that can be applied to the study of nuclear structures in mammalian cells. PMID:25555577

  17. An Optofluidic Lens Array Microchip for High Resolution Stereo Microscopy

    Mayurachat Ning Gulari

    2014-08-01

    Full Text Available We report the development of an add-on, chip-based, optical module—termed the Microfluidic-based Oil-immersion Lenses (μOIL chip—which transforms any stereo microscope into a high-resolution, large field of view imaging platform. The μOIL chip consists of an array of ball mini-lenses that are assembled onto a microfluidic silicon chip. The mini-lenses are made out of high refractive index material (sapphire and they are half immersed in oil. Those two key features enable submicron resolution and a maximum numerical aperture of ~1.2. The μOIL chip is reusable and easy to operate as it can be placed directly on top of any biological sample. It improves the resolution of a stereo microscope by an order of magnitude without compromising the field of view; therefore, we believe it could become a versatile tool for use in various research studies and clinical applications.

  18. A high resolution Timing Counter for the MEG II experiment

    De Gerone, M.; Bevilacqua, A.; Biasotti, M.; Boca, G.; Cattaneo, P. W.; Gatti, F.; Nishimura, M.; Ootani, W.; Pizzigoni, G.; Rossella, M.; Shibata, N.; Siccardi, F.; Simonetta, M.; Uchiyama, Y.; Yoshida, K.

    2016-07-01

    The development of a Timing Counter detector designed for the MEGII upgrade of the MEG experiment, which strives to improve the sensitivity on the μ+ →e+ γ decay of an order of magnitude, is presented. It is based on two sets of counters (sectors) arranged on a semi-cylindrical structure; each sector consists of 256 counters. Each counter consists of tile of fast scintillator with a dual-side read-out based on SiPM arrays in series connection. The high granularity has two advantages: optimized size for achieving high resolution (75 ps) for the single counter, and a signal e+ crosses several counters, so that resolution improves by averaging multiple time measurements. A prototype has been built and tested both in BTF and PSI facilities in order to prove the multi-hit scheme in MEG-like beam conditions. A 35 ps resolution with eight hits has been obtained with a e+ beam at 100 kHz. The first sector will be tested in the MEG II pre-engineering run planned at the end of 2015.

  19. High-resolution multimodal clinical multiphoton tomography of skin

    König, Karsten

    2011-03-01

    This review focuses on multimodal multiphoton tomography based on near infrared femtosecond lasers. Clinical multiphoton tomographs for 3D high-resolution in vivo imaging have been placed into the market several years ago. The second generation of this Prism-Award winning High-Tech skin imaging tool (MPTflex) was introduced in 2010. The same year, the world's first clinical CARS studies have been performed with a hybrid multimodal multiphoton tomograph. In particular, non-fluorescent lipids and water as well as mitochondrial fluorescent NAD(P)H, fluorescent elastin, keratin, and melanin as well as SHG-active collagen has been imaged with submicron resolution in patients suffering from psoriasis. Further multimodal approaches include the combination of multiphoton tomographs with low-resolution wide-field systems such as ultrasound, optoacoustical, OCT, and dermoscopy systems. Multiphoton tomographs are currently employed in Australia, Japan, the US, and in several European countries for early diagnosis of skin cancer, optimization of treatment strategies, and cosmetic research including long-term testing of sunscreen nanoparticles as well as anti-aging products.

  20. A new matching algorithm for high resolution mass spectra

    Hansen, Michael Edberg; Smedsgaard, Jørn

    2004-01-01

    We present a new matching algorithm designed to compare high-resolution spectra. Whereas existing methods are bound to compare fixed intervals of ion masses, the accurate mass spectrum (AMS) distance method presented here is independent of any alignment. Based on the Jeffreys-Matusitas (JM...... accurate mass spectra from an analysis of extracts of 80 isolates representing the nine closely related species in the Penicillium series Viridicata. Using this algorithm we can obtain a retrieval performance of approximate to97-98% that is comparable with the best of the existing methods (e.g., the dot......) distance, a difference between observed peaks across pairs of spectra can be calculated, and used to find a unique correspondence between the peaks. The method takes into account that there may be differences in resolution of the spectra. The algorithm is used for indexing in a database containing 80...