Various methods have been proposed to condition an electron beam in order to reduce its emittance effect and to improve the short-wavelength free electron laser (FEL) performance. In this paper, we show that beam conditioning does not result in a complete elimination of the emittance effect in an alternating-gradient focusing FEL undulator. Using a one-dimensional model and a three-dimensional simulation code, we derive a criteria for the emittance limitation of a perfectly conditioned beam that depends on the focusing structure.
The authors describe measurements of emittance made on samples of solar cell coverglasses incorporating new coatings both on C-7940 fused silica and on CMX ceria doped microsheet. Samples of a conventional, MgF_2 coating on the same two types of coverglass substrates were included in the measurements as controls. Measurements were made by the calorimetric method of total hemispherical emittance within a cooled chamber as well as by the more common infrared reflectance method. Emittance enhancements from 1 to 4% were measured for the new coatings.
An apparatus is described for measuring the total hemispherical emittance of pipes of a length suitable for use in a prototype solar collector. The calorimetric method used requires measurements of the temperatures of the surface of the test pipe and of a concentric outer cylinder and measurement of the electrical power used to heat the test pipe. Measurements were made of the total hemispherical emittance of black chrome, nickel, and bare steel pipes as a function of temperature. The emittance of the black chrome surfaces increased significantly from an extrapolated value of about 0.1 at 25 deg C to values on the order of 0.3-0.4 at 300 deg C. The extrapolated values for black chrome agreed with measurements made using other techniques at room temperature. The results for the nickel-plated pipe agreed with total emittance calculated from spectral reflectance data.
Of the many ways of detecting high redshift galaxies, the selection of objects due to their redshifted Ly-alpha emission has become one of the most successful. But what types of galaxies are selected in this way? Until recently, Ly-alpha emitters were understood to be small star-forming galaxies, possible building-blocks of larger galaxies. But with increased number of observations of Ly-alpha emitters at lower redshifts, a new picture emerges. Ly-alpha emitters display strong evolution in their properties from higher to lower redshift. It has previously been shown that the fraction of ultra-luminous infrared galaxies (ULIRGs) among the Ly-alpha emitters increases dramatically between redshift three and two. Here, the fraction of AGN among the LAEs is shown to follow a similar evolutionary path. We argue that Ly-alpha emitters are not a homogeneous class of objects, and that the ...
A calorimetric vacuum emissometer (CVE) capable of measuring total hemispherical emittance of surfaces at elevated temperatures was designed, built, and tested. Several materials with a wide range of emittances were measured in the CVE between 773 to 923 K. These results were compared to values calculated from spectral emittance curves measured in a room temperature Hohlraum reflectometer and in an open-air elevated temperature emissometer. The results differed by as much as 0.2 for some materials but were in closer agreement for the more highly-emitting, diffuse-reflecting samples. The differences were attributed to temperature, atmospheric, and directional effects, and errors in the Hohlraum and emissometer measurements ({+-} 5 percent). The probable error of the CVE measurements was typically less than 1 percent.
The radiative heat loss from a surface is determined by its total hemispherical emittance, which consequently plays an important role in aerospace and solar applications. This study compares emittances measured calorimetrically with values derived from near normal incidence spectral reflectance measurements. This optical derivation is based on a number of assumptions which limit the accuracy if not sufficiency fulfilled. These assumptions include sample specularity, a straybody character beyond the range of measurement, only small variations of emittance with temperature, and a perfectly smooth sample surface. The comparison of calorimetrically and optically derived emittance performed in this study not only quantifies the errors introduced by insufficient fulfillment of the assumptions but also identifies which assumption causes the dominant error. The calorimetric emissometer, constructed for this ...
A brief comparative review of possible mercury free fluorescent lighting technologies is presented, including rare-gas positive column discharges, molecular discharges, and dielectric barrier discharges. Detailed experimental results on xenon positive column discharges will then be considered. In order to judge whether xenon-based discharges are a viable UV source it is necessary to measure the radiant emittance (power per unit area) for the vacuum ultraviolet (VUV) resonance xenon emission at 147 nm. Two techniques to determine the VUV radiant emittance have been developed and applied to xenon discharges. One method combines the measured resonance level density using absorption spectroscopy and a calculation of the trapped decay rate for the resonance radiation to arrive at the radiant emittance at 147 nm. A second method utilizes a direct measurement of the radiance (power per ...
In recent years, increased attention has been focused on the use of lasers in different fabrication steps of solar cells, in particular laser doping to form emitter and/or selective emitter. In this method the laser energy is used to melt silicon, allowing the diffusion of dopant atoms to occur in the liquid phase. The main advantage of this method is the localised nature of the laser beam, which melts and diffuses a limited area without heating the bulk, therefore reducing the possible degradation associated with high temperature processes. At the University of New South Wales a novel laser doping method was developed, which combines the formation of the selective emitter with a self-aligned metallisation pattern. Despite achieving high efficiencies, concerns arose regarding the adhesion ...
Thermophotovoltaic (TPV) systems are attractive possibilities for direct thermal-to-electric energy conversion, but have typically required the use of black body radiators operating at high temperatures. Recent advances in both the understanding and performance of solid rare-earth oxide selective emitters make possible the use of TPV at temperatures as low as 1200K. Both selective emitter and filter system TPV systems are feasible. However, requirements on the filter system are severe in order to attain high efficiency. A thin-film of a rare-earth oxide is one method for producing an efficient, rugged selective emitter. An efficiency of 0.14 and power density of 9.2 W/KG at 1200K is calculated for a hypothetical thin-film neodymia (Nd2O3) selective emitter TPV system that uses radioisotope decay as the thermal energy source.
A 20-MeV proton accelerator is developed by Proton Engineering Frontier Project (PEFP) at Korea Atomic Energy Research Institute (KAERI). The 20MeV accelerator consists of 50keV proton injector, 3MeV RFQ (Radio frequency Quadrupole), 20MeV DTL (Drift Tube Linac) and 20MeV beam line. The beam profile was measured at the end of the 20MeV beam line with wire scanner. Moreover the beam emittance was calculated from the quad scan method using beam line quadrupole magnets. In this paper, the beam profile measurement results are presented and the emittance measurement from the quad scan method is discussed
An analytical method was proposed for calculating radiative fluxes incident on a planar circular detector from a volume multiple point chemi- or bio-luminescent source inside a coaxial cylindrical reactor. The method was designed for a cylindrical reactor when the surface reflections were neglected and when chemi- or bio-luminescence reaches a detector embedded in the same homogeneous optical medium as the point emitters of the volume multiple point source model. The radiative fluxes from arbitrarily distributed point emitters were expressed by one generalized quadruple-integral formula. Then some double- and single-integral formulas were obtained for calculating radiative fluxes from identically radiating point emitters uniformly distributed within the reactor. Selected results were compu...
In order to judge the potential fluorescent lamp applications of various low-pressure positive column discharges it is necessary to measure the absolute power emitted in the ultraviolet region of the spectrum. For rare-gas discharges the principle emission occurs in the vacuum ultraviolet so that it is difficult to measure the radiant emittance (power per unit area) of the resonance radiation by standard methods. Two independent techniques are discussed for measuring the radiant emittance of positive column discharges in the vacuum ultraviolet. These techniques are used to study xenon positive column discharges at the resonance wavelength of 147 nm. The first method relies on the measurement of the resonance level density by absorption techniques. The effective decay rate of the resonance level is then determined by the simulation of resonance radiation transport. These two quantities are combined to ...
Total hemispherical emittance was measured for the SP-100 reactor fuel cladding alloy (Nb-l% Zr). Based on a standard test method (ASTM C 835-82), experiments were conducted on a reference sample of oxidized stainless steel and then on a sample of actual cladding. The sample is heated in a vacuum by passing DC current through it until reaching equilibrium. Measurements are made of the electrical power dissipated in the sample and of the surface temperature. Using the Stefan-Boltzmann Law and some key assumptions concerning conductive and radiative heat transfer, the measured quantities are used to calculate emittance. Calculated values for unoxidized cladding range from 0.159 +/- 5.35% at 913 K to 0.200 +/- 4.51% at 1091 K. Highest value measured after onset of visible oxidation was 0.339 +/- 3.92% at 1269 K.... SP-100, Reactor, Emittance, Niobium, Fuel cladding, Emissivity.
Radiation damage and its recovery in the light emittance efficiency and the attenuation length of barium fluoride (BaF_2) scintillator have been investigated. The light yield and transmittance of small samples of BaF_2 scintillator were measured after #gamma#-irradiation from 0.5x10"4 to 1.1x10"5 Gy for deterioration, and after sunlight exposure for recovery. Suspension of deterioration was observed both in light yield and in attenuation length at an integrated dose of #gamma#-rays of about 10"4 Gy. Fairly good and quick recovery of the deteriorated BaF_2 scintillator was obtained by sunlight exposure. Using a Monte Carlo simulation method, the dependence of the light emittance efficiency on #gamma#-irradiation and sunlight exposure was studied. It has been found that the light emittance efficiency, as well as the attenuation length, is influenced by #gamma#-irradiation and sunlight exposure. (orig.).
The principle is described of a method using low-activity emitters as the primary radiation source for analysis. The selection of the radiation source and the detection methods including the assessment of the applicability of various radiation detectors are discussed. The benefits and the constraints of the method are considered. Practical examples are presented showing the application possibilities of the method for testing the thickness of bearing layers, piston ring coats, lead layers, etc. The possibility is shown of applying the rapid test for the composition of tungsten and chromium alloyed metal materials in testing complex systems. (J.K.).
The design of a reaction cell which permits the investigation of the sorption kinetics of microcomponents without separation of the phases under automated condition has been described. The use of thin-layer inorganic sorbents obtained by depositing films of a sorbing substance from aqueous solutions on flat substrates of small thickness makes it possible to determine the extent of sorption even at small values in the case of /beta/ emitters with a low energy and /alpha/ emitters. Detailed observation of the kinetics of isotopic exchange in the CdS-/sup 115m/Cd-HNO/sub 3/ system has made it possible to reveal at least four stages in the process during the time of observation.
Two methods to cool muon beams deeply below the limit conventionally established for the ionization cooling are proposed. In Phase Ionization Cooling (PIC), the beam is focused at wedge absorber plates each half of particle oscillation period by imposing a weak parametric resonance along the beam path. The resonance growth of particle amplitude is surmounted by the ionization cooling. At optimum, such arrangement results in reduction of each of two transverse emittances by an order of value in addition to the preceding 6D ionization cooling. Next, resonance focusing and transverse cooling can be continued in the regime of a fast Reverse Emittance Exchange (REMEX). Here, the sign of the absorber wedge is opposite to PIC while the dispersion increased. REMEX to be accompanied by the bunch lengthening and acceleration in order to maintain the relative energy spread at an appropriate level. The limitations due to energy ...
A temperature gradient across a thick ({ge}.1mm) film selective emitter will produce a significant reduction in the spectral emittance from the no temperature gradient case. Thick film selective emitters of rare earth doped host materials such as yttrium-aluminum-garnet (YAG) are examples where temperature gradient effects are important. In this paper a model is developed for the spectral emittance assuming a linear temperature gradient across the film. Results of the model indicate that temperature gradients will result in reductions the order of 20{percent} or more in the spectral emittance. {copyright} {ital 1997 American Institute of Physics.}
New rare earth oxide emitters show greater efficiency than previous emitters. As a result, based on a simple model the efficiency of these emitters was calculated. Results indicate that the emission band of the selective emitter must be at relatively low energy (less than or equal to .52 eV) to obtain maximum efficiency at moderate emitter temperatures (less than or equal to 1500 K). Thus low bandgap energy PV materials are required to obtain an efficient thermophotovoltaic (TPV) system. Of the 4 specific rare earths (Nd, Ho, Er, Yb) studied Ho has the largest efficiency at moderate temperatures (72 percent at 1500 K). A comparison was made between a selective emitter TPV system and a TPV system that uses a thermal emitter plus a band pass filter to make the thermal emitter behave like a selective ...
Thin films of high temperature garnet materials such as yttrium aluminum garnet (YAG) doped with rare earths are currently being investigated as selective emitters. This paper presents a radiative transfer analysis of the thin film emitter. From this analysis the emitter efficiency and power density are calculated. Results based on measured extinction coefficients for erbium-YAG and holmium-YAG are presented. These results indicated that emitter efficiencies of 50 percent and power densities of several watts/sq cm are attainable at moderate temperatures (less than 1750 K).
The purpose of this study is to identify the radiative heat transfer augmentation by a coaxial cylinder introduced in the infinite cylindrical pipe enclosing a participating gas. The gas is either a mixture of water vapor and carbon dioxide or gray. The gas is assumed to be homogeneous at a constant temperature, and has a refractive index of unity. All of the surfaces are opaque and gray, diffusely emitting and reflecting at a constant temperature. The effect of system diameter, diameter ratio, wall emittances, gas and surface temperatures, mixture component on heat transfer augmentation are studied by using the zone method with participating gas radiative properties evaluated from the weighted sum of gray gases model. From the radiative equilibrium condition, the installed wall temperature is formulated and calculated by the iteration method. If the medium is a gray gas, the augmentation observed are negligible. For the ...
A method for conditioning electron beams is proposed, making use of the TM{sub 210} mode of microwave cavities, to reduce the axial velocity spread within the beam, in order to enhance gain in resonant electron beam devices, such as the free-electron laser (FEL). Effectively, a conditioner removes the restriction on beam emittance. The conditioner is analyzed using a simple model for beam transport and ideal RF cavities. Analysis of an FEL is employed to evaluate performance with reduced axial velocity spread. Examples of FELs are presented showing the distinct advantage of conditioning.
The additional error in measurement of the thickness of Kh18N10T steel for possible changes in composition with an energy of the photons of ionizing radiation of 10-80 keV was evaluated. The desirability of use of a type REIS-I x-ray emitter in measurement of the thickness of steel up to 1 mm is shown. The instrument provides measurement of the thickness of steel in the 0.1-1.0 mm range with a reproducibility of the results with an error not exceeding 0.5-1.0%. The measurement error with corrugations characteristic of bellows does not exceed 5%.
Context. The I(15.01 A)/I(16.78 A) emission line intensity ratio in Fe XVII has been reported to deviate from its theoretical value in solar and stellar X-ray spectra. This is attributed to opacity in the 15.01 A line, leading to a reduction in its intensity, and was interpreted in terms of a geometry in which the emitters and absorbers are spatially distinct. Aims. We study the I(15.01 A)/I(16.78 A) intensity ratio for the active cool dwarf EV Lac, in both flare and quiescent spectra. Methods. The observations were obtained with the Reflection Grating Spectrometer on the XMM-Newton satellite. The emission measure distribution versus temperature reconstruction technique is used for our analysis. Results. We find that the 15.01 A line exhibits a significant enhancement in intensity over the optically thin value. To our knowledge, this is the first time that such an enhancement has been detected on such a sound statistical basis. We interpret ...
Traditionally wafer bumps are made from Pb containing solders. Over 20 years ago IBM recognized that {sup 210}Pb has a decay chain resulting in a 5.4 MeV alpha particle that induces soft errors. A variety of efforts to produce and characterize low alpha Pb ensued. Work at Honeywell over the past several years has shown that low alpha lead activity does not follow the decay signature predicted from {sup 210}Pb secular equilibrium. Data are presented indicating that smelting has a minimal effect on {sup 210}Pb/{sup 210}Po secular equilibrium and that other trace radionuclides are the alpha source. The implications of these data to possible alpha emitter sources in lead free solders are discussed, along with a method developed by Honeywell to remove alpha emitters from lead free solder components.
Heavily doped emitters with low saturation current density are of particular interest for selective emitter solar cells. These emitters can be obtained by laser doping through the phosphosilicate glass layer formed after thermal diffusion from POCl3 gas. The experimental results show that in contrast to purely POCl3 furnace-diffused emitters, the saturation current density of laser-doped emitters does not increase linearly as sheet resistance decreases, but rather features two distinct regimes. In one of these regimes, the saturation current density is found to decrease as the sheet resistance decreases, reaching values lower than those of furnace emitters. This peculiar behaviour was explained by both qualitative analysis and numerical simulations.
The authors present the emitter efficiency results for the thin film 25 percent Ho YAG (Yttrium Aluminum Garnet, Y3Al5O12) selective emitter from 1000 to 1700 K with a platinum substrate. Spectral emittance and emissive power measurements were made (1.2 less than lambda less than 3.2 microns) and used to calculate the radiative efficiency. The radiative efficiency and power density of rare earth doped selective emitters are strongly dependent on temperature and experimental results indicate an optimum temperature (1650 K for Ho YAG) for thermophotovoltaic (TPV) applications.
La{sub 1-x}Sr{sub x}MnO{sub 3} (LSMO) compounds (0.175{<=}x{<=}0.30) were prepared by conventional solid-state reaction method. Temperature dependence of the total hemispherical emittance ({epsilon}{sub H}) of the compounds from 173 to 373 K was measured on a calorimetric emissometer (CE) which was constructed based on the steady-state calorimetric method. The compounds show thermochromic properties and {epsilon}{sub H}'s have low value at low temperature and have high value at high temperature, because the compounds are dominated by metallic phase and insulator phase, respectively. We use the phase separation model to interpret the temperature dependence of {epsilon}{sub H}. (author)
The cold effluents (sanitary waste and decontaminated radioactive water) are flocculated with sodium phosphate and pumped through a trickling filter. The average decontamination obtained is about 86% for alpha emittera and 76% for beta emitters. The cool effluents (activity < 10/sup -3/ mu c/ml) can be treated by several methods. Provisions have been made for two successive chemical flocculations eventually followed by an adsorptlon. The warm waste treatment (activity between 10/sup -3/ and 1 mu c/ml) is still in the experimental stage. The following methods are used: evaporation for some chemically contaminated wastes, browncoal filtration for reactor effluents, and a combination of chemical treatment and browncoal adsorption in other cases. (auth)
In the CLIC main linac it is very important to minimise the trajectory excursion and consequently the emittance dilution in order to obtain the required luminosity. Several algorithms have been proposed and lately the ballistic method has proved to be very effective. The trajectory method described in this Note retains the main advantages of the latter while adding some interesting features. It is based on the separation of the unknown variables like the quadrupole misalignments, the offset and slope of the injection straight line and the misalignments of the beam position monitors (BPM). This is achieved by referring the trajectory relatively to the injection line and not to the average pre-alignment line and by using two trajectories each corresponding to slightly different quadrupole strengths. A reference straight line is then derived onto which the beam is bent by a kick obtained by moving the first quadrupole. The ...
The As Pontes coal-fired power plant in northwest Spain is the largest single emitter of sulphur dioxide in the 'old' EU15. The plant is also among the largest emitters of nitrogen oxides and carbon dioxide in the region, according to the EPER (European Pollutant Emission Register). But Spain has also several other large emitters of air pollutants. The Andorra which is located in the province of Teruel is one of them. The Andorra power plant emitted 209,148 tones of SO{sub 2} in 2002 which makes it the second largest single emitter of SO{sub 2} in the EU15. It also emitts large quantities of NOx. Also in the northwest of Spain, the Composilla and La Robla power plants are the SO{sub 2} and NOx emitters.
Abstract A fabrication process for Emitter-Wrap-Through solar cells on monocrystalline material with high quality gap passivation by wet thermal silicon dioxide is investigated. Masking and structuring steps are performed by screen-printing technology. Via-holes are created by an industrially applicable high-speed laser drilling process. The cell structure features a selective emitter structure fabricated in a single high temperature step: a highly doped emitter at the via-holes and the rear side, allowing for a low via-hole resistivity as well as a low resistivity contact to screen-printed pastes, and a moderately doped front side emitter exhibiting high quantum efficiency in the low wavelength range. Therefore a novel approach is applied depositing either doped or undoped PECVD silicon d...
Introduction.Microfluidic technology allows fast reactions in a simple experimental setup, while using very low volumes and amounts of starting material. Consequently, microfluidic technology is an ideal tool for radiolabeling reactions involving short-lived positron emitters. Optimization of the complex array of different reaction conditions requires knowledge of the different reaction parameters linked to the microfluidic system as well as their influence on the radiochemical yields. 1-(5-Deoxy-5-fluoro-?-d-arabinofuranosyl)-2-nitroimidazole ([18F]FAZA) is a frequently used radiotracer for PET imaging of tumor hypoxia. The present study describes the radiosynthesis of [18F]FAZA by means of microfluidic technology and subsequent small animal PET imaging in EMT-6 tumor-bearing mice.Methods...
The results of radon concentration measurements inside of the Gabriel caves of Mexico, during three consecutive two-month periods covering almost three seasons, are reported in the present work. The radio-ecological importance of this site is related to the radon and its concentration-dynamic behavior in the cave. Further interest in radiation safety motivated this initiative since routine biological field work is done, with people spending long periods of time there. CR-39 passive nuclear track detector was chosen for this survey. Radon concentration levels decrease during the rainy season and show different values depending on the ventilation and geometeorological structure. Measured values range between 956 and 4931Bqm{sup -3}, an indication that radon doses may exceed the allowed values for workers. This project is part of a larger study of indoor radon alpha emitters in Mexican caves.
The results of radon concentration measurements inside of the Gabriel caves of Mexico, during three consecutive two-month periods covering almost three seasons, are reported in the present work. The radio-ecological importance of this site is related to the radon and its concentration-dynamic behavior in the cave. Further interest in radiation safety motivated this initiative since routine biological field work is done, with people spending long periods of time there. CR-39 passive nuclear track detector was chosen for this survey. Radon concentration levels decrease during the rainy season and show different values depending on the ventilation and geometeorological structure. Measured values range between 956 and 4931Bqm-3, an indication that radon doses may exceed the allowed values for workers. This project is part of a larger study of indoor radon alpha emitters in Mexican caves.
Recently Emma and Stupakov identified a fatal flaw in a Free Electron Laser (FEL) beam conditioning scheme. They showed that the conditioning is always accompanied by a projected transverse emittance growth that is so large as to make the beam conditioning completely impractical for short wavelength FELs. Furthermore, they provided a general proof along with evidence of computer simulation and reached a conclusion that any beam conditioner, regardless of the method, would suffer from the same constraints and limitations. In this paper, the author proposes an easy surgical removal of the fatal flaw by making a critical yet simple modification to the very scheme analyzed, thus resurrect the beam conditioning for short wavelength FELs. More generally, the also explain why a general search for removing have failed, why the concept and definition of beam conditioning.
GaInP solar cell interfaces were characterized by admittance spectroscopy. Admittance spectroscopy is shown to be sensitive to the band structure at the heterojunction interfaces. In particular, a correlation between activation energy of the capacitance step in a capacitance versus temperature plot and effective potential barrier for majority carriers is demonstrated, indicating a new method for the determination of potential barriers at heterointerfaces. Using this technique, the effective potential barrier for holes at the p-Al_0_._5_3In_0_._4_7P/p-GaAs interface is found to be equal to 0.6 eV. Effects of interface defects and spreading resistance in the emitter of solar cells are illustrated and discussed.
The interaction of thermal radiation with conduction and convection in thermally developing absorbing, emitting, nongray gas-particulate turbulent suspension flow through a circular tube is investigated. The contribution of thermal radiation is obtained through evaluation of the total hemispherical emittance of the particulate cloud and through evaluation of single band absorptances for molecular gases, modified to account for the interaction with the particles. The governing differential equation is derived as a (nonlinear) energy equation, coupled with integral equations to find the thermal radiation contributions. The energy equation is solved numerically by an implicit finite difference method with an iterative procedure. Qualitative results for Nusselt numbers are shown for a variety and range of parameters, such as optical thickness of particulates and single molecular gas bands, relative gas band position and band width, and temperature ...
In this paper we discuss the effect on the emittance of the residual dispersion in the insertion devices. The dispersion in the straights could be generated by the lattice error, trim dipole, and insertion device. The effect on the emittance is examined, and the dispersion tolerances are given for the NSLS-11.
We numerically demonstrate selective near-field localization determined by the polarization state of a single emitter coupled to plasmonic nano-cluster. Seven gold nanospheres are carefully arranged such that up to ten polarization states of the single emitter, including linear, circular, and elliptical polarizations, can be distinguished via the distinct field localization in four gaps. The ability to transform polarization state into field spatial localization may find application for single emitter polarization analysis.
We report experimental evidence of a previously unseen species-dependent effect in the transverse emittances of momentum analysed /sup 28/Si/sup -/, /sup 58/Ni/sup -/ and /sup 197/Au/sup -/ ion beams generated by caesium ion sputtering. The high-resolution emittance measurement techniques employed in this work have enabled us to estimate the energy spreads of these ion beams; differences in the widths of the energy distributions are the origin of the observed differences in emittances of the ion beams investigated. (author).
The performance of a thermophotovoltaic (TPV) converter for solar energy is compared with that of direct solar energy conversion by silicon and germanium solar cells. The optical selectivity of an intermediate emitter is computed. Experimental results on selective emission, based on selectively emitting materials and on antireflection coatings on metals, are reported. For a TPV converter equipped with silicon solar cells, no selective emitter is found to yield better results than would be obtained by direct conversion. A TPV converter with germanium cells operating with a ThO/sub 2/-coated tungsten emitter, however, may achieve a conversion efficiency superior to that of direct solar energy conversion by either silicon or germanium solar cells.
To achieve high efficiency for the conversion of electron kinetic energy in an electron beam to electromagnetic energy in a Free Electron Laser (FEL), it is important to improve the beam quality. And hence, it is necessary to study and minimize the emittance growth of the beam. According to the requirements for the beam quality in an FEL, the author analyzed the emittance growth caused by the jump of the electric field in an accelerator, energy increase, wakefield in a waveguide, space charge effect and distribution of particles in a beam as well as the wakefield in a deflect system etc. The author also estimated the emittance change caused by the variation of the microwave field from the gun to the first accelerator for such case.
This paper presents an analysis of the performance of a selective emitter using small particles of rare earth compounds stable at high temperatures in a low emittance inert gas stream. An expression for the spectral emissive power excluding radiation scattering was derived to include the radiation in the emission band, produced by electronic transitions of the rare earth ion, and the continuum radiation outside the emission band produced by the rare earth host. Preliminary results suggest that a selective emitter based on suspended rare earth oxide particles will have high efficiency and merits further experimental investigation. {copyright} {ital 1996 American Institute of Physics.}
This paper identifies some of the issues which arise in the consideration of the derivation of new limits on exposure to internal emitters. Basic and secondary radiation protection limits are discussed. Terms are defined and applied to the limitation of risk from stochastic effects. Non-stochastic data for specific internal emitters (/sup 131/I and the radium isotopes) are presented. Emphasis is placed on the quantitative aspects of the limit setting problem. 65 references, 2 figures, 12 tables.
Investigation of selective emitter solar cells has been undertaken using both device fabrication and accurate two-dimensional simulation program. Our results show that selective emitter solar cells exhibit a relatively low fill factor because of minority carriers crowding at the lateral junction. It is also found that carrier recombination in the space-charge region of the lateral junction limits open-circuit voltage improvements
The progress made in particle detection, particularly the design of multi-detectors, like INDRA, that cover a solid angle of almost 4{pi}, have given a new impetus to heavy ion collisions. These detectors are demanding for an efficient way of selecting events that have a common history or similar features, for instance the events representing the de-excitation of a unique emitter. The problem is to find the adequate variable on which the discrimination can be based. Different methods are proposed in this work, the common point is that they require efficient models to reproduce and analyse experimental data in order to apprehend the equation of state of nuclear matter. Most of these models are based on the numerically solving of the nuclear Boltzmann equation. The application to the Ni + Ni reaction with an energy ranging from a few A.MeV to more than 50 A.MeV illustrates this work. (A.C.)
We report experimental evidence of a previously unseen species-dependent effect in the transverse emittances of momentum-analyzed {sup 28}Si{sup {minus}}, {sup 58}Ni{sup {minus}}, and {sup 197}Au{sup {minus}} negative-ion beams generated by cesium-ion sputtering. The differences in the emittances are found to be principally correlated with differences in the energy spreads in the respective ion beams, which have their origins in the sputter-ejection negative-ion formation process. The experimental equipment and techniques utilized for emittance data acquisition and analysis, and evidence for a species-dependent effect in the emittances and brightnesses of the subject ion beams, are presented in this paper.
The total hemispherical emittance of an oxide film that formed on 6061-T6 aluminium alloy parts in the Tower Shielding Reactor-II at Oak Ridge National Laboratory was measured from 295 to 773 K using an emissometer and/or a calorimeter. The emittance of this film was critically needed for heat transfer calculations in a simulated loss-of-coolant accident of the reactor. X-ray diffraction analysis identified the film as boehmite (Al_2O_3 x H_2O), which dehydrated to alumina (Al_2O_3) upon heating above 473 K. The measured emittances for the alumina film are in excellent agreement with published values for anodized aluminum films and for bulk alumina. Published values of the emittance of boehmite could not be found for comparison, but evidence is presented that some anodization processes for aluminum yield boehmite and not alumina films.
The emittances of hydrogen and deuterium negative ion beams produced by volume ion sources have been measured in a transverse plane normal to the beam trajectory. The extraction voltage was varied from 10 to 40 kV, and the transverse magnetic field in the Penning discharges was varied from 0.1 to 0.2 T. Measurements were made on beams with current densities up to 60 mA/cm/sup 2/ at Oak Ridge National Laboratory with an emittance scanner originally developed at Los Alamos National Laboratory. The beam profile at the scanner can be used to improve the accuracy of the emittance measurements. Other factors affecting emittance measurements are discussed. This analysis may be applicable to other ion sources. 6 figs.
A comparison of the loss mechanisms in screen-printed solar cells relative to buried contact cells and cells with photolithography-defined contacts is presented in this paper. Model calculations show that emitter recombination accounts for about 0.5% absolute efficiency loss in conventional screen-printed cells with low-sheet-resistance emitters. Ohmic contact to high-sheet-resistance emitters by screen-printing has been investigated to regain this efficiency loss. Our work shows that good quality ohmic contacts to high sheet-resistance emitters can be achieved if the glass frit chemistry and Ag particle size are carefully tailored. The melting characteristics of the glass frit determine the firing scheme suitable for low contact resistance and high fill factors. In addition, small to regular Ag particles were found to help achieve a higher open-circuit voltage and maintain a low contact resistance. ...
Nuclear Act of Korea requires the manifest of low and intermediate level radioactive waste generated from nuclear power plants and other nuclear facilities prior to deliver to a disposal sites. Individual history records of the radioactive waste should be described the information about the activity of nuclides in the drum, total activity, weight, the type of waste. So a fully automated nuclide analysis assay system(non-destructive) of a radwaste drum was developed. For the nuclides that could not be analysed directly by MCA, the activities of the representative {gamma}-emitters(Cs-137, Co-60) contained in the drum were measured by using that system. Then the scaling factors were used to calculate the activities of {alpha} - and {beta}-emitters. This assay system divided a drum into 8 segments, a segment into 8 sectors to minimize analysis error, and used several methods(transmission ratio, differential peak absorption, ...
CEA-Valduc produces some radioactive waste (mainly alpha emitters). Legislation requires producers to sort their waste by activity and type of isotopes, and to package them in order to forward them to the appropriate reprocessing or storage facility. Our lab LMDE (laboratory for measurements on nuclear wastes and valuation) is in charge of the characterization of the majority of waste produced by CEA-Valduc. Among non-destructive methods to characterize a radioactive object, gamma-spectroscopy is one of the most efficient. We present to this conference the method we use to characterize nuclear waste and the system we developed to characterize our germanium detectors. The goal of this system is to obtain reliable numerical models of our detectors and calculate their efficiency curves. Measurements are necessary to checks models and improve them. These measurements are made on a bench using pinpoint sources ("1"3"3Ba, ...
This thesis deals with the evaluation of Solar Grade Silicon (SoG-Si) purified by different techniques, and also the fabrication and characterization of high efficiency and advanced bifacial solar cells. In the beginning of Chapter 1, various SoG-Si production methods relevant for this work are qualitatively described. The three feedstock materials used in this work are from the Fluidized Bed Reactor (FBR) process, metallurgical feedstock-I and feedstock-II process. In metallurgical feedstock-I, the lifetime of the minority charge carriers in multicrystalline silicon (mc-Si) samples at the grain boundaries are found to be higher than the grains themselves possibly due to lower resistivities in the grain boundaries. The efficiency of the best solar cell obtained using the mc-Si metallurgical feedstock-I is 16.1%. It has been identified that the fast light induced degradation, whose magnitude is lower than that of a reference cell suggests the formation of a B-metal ...
In radiation therapy with hadron beams, conformal irradiation to a tumour can be achieved by using the properties of incident ions such as the high dose concentration around the Bragg peak. For the effective utilization of such properties, it is necessary to evaluate the volume irradiated with hadron beams and the deposited dose distribution in a patient's body. Several methods have been proposed for this purpose, one of which uses the positron emitters generated through fragmentation reactions between incident ions and target nuclei. In the previous paper, we showed that the maximum likelihood estimation (MLE) method could be applicable to the estimation of beam end-point from the measured positron emitting activity distribution for mono-energetic beam irradiations. In a practical treatment, a spread-out Bragg peak (SOBP) beam is used to achieve a uniform biological dose distribution in the whole target volume. ...
The pure xenon dc positive column discharge has been characterized for various xenon pressures, currents, and discharge tube radii. The absolute output at the 147 nm resonance transition has been measured using two independent techniques to yield the radiant emittance at 147 nm (power per unit surface area). The efficiency of 147 nm production is obtained by combining the measured radiant emittance with the measured electrical power per unit length deposited in the gas. The radiant emittance and the efficiency are the two principle figures of merit for characterizing the discharge as a source of VUV radiation. It is observed that the trends in efficiency and radiant emittance change substantially when the discharge transitions from two-step electron impact excitation/ionization at higher pressures to single-step electron impact ionization at lower pressures. Modeling of the xenon positive column ...
In this paper the authors present the first emitter efficiency results for the thin film 40 percent Er-1.5 percent Ho YAG (Yttrium Aluminum Garnet, Y3Al5O12) and 25 percent Ho YAG selective emitter at 1500 K with a platinum substrate. Spectral emittance and emissive power measurements were made (1.2 less than lambda less than 3.2 microns). Emitter efficiency and power density are significantly improved with the addition of multiple rare earth dopants. Predicted efficiency results are presented for an optimized (equal power density in the Er, (4)I[sub 15/2]-(4)I[sub 13/2] at 1.5 microns, and Ho, (5)I[sub 7]-(5)I[sub 8] at 2.0 micron emission bands) Er-Ho YAG thin film selective emitter.
The Linac Coherent Light Source (LCLS) is an x-ray free-electron laser (FEL) project based on the SLAC linac. The LCLS Photoinjector beamline has been designed to deliver 10-ps long electron bunches of 1 nC with a normalized projected transverse emittance smaller than 1.2 mm-mrad at 135 MeV. Tolerances and regulation requirements are tight for this tuning. Half of the total emittance at the end of the injector comes from the ''cathode emittance'' which is 0.7 mm-mrad for our nominal 1nC tuning. As the ''cathode emittance'' scales linearly with laser spot radius, the emittance will be dramatically reduced for smaller radius, but this is only possible at lower charge. In particular, for a 0.2 nC charge, we believe we can achieve an emittance closer to 0.4 mm-mrad. This working point will be ...
This letter describes a new simple fabrication process, developed recently for blue response'' improvement in low-cost polycrystalline silicon solar cells. A selective emitter is created by heavily doping the emitter, followed by a wet etching-back of the cell area between the fingers. An improvement up to 17 mV in {ital V}{sub oc}, 1.5 mA/cm{sup 2} in {ital J}{sub sc}, and 1% (absolute value) in {eta} is obtained. Effective phosphorus gettering, self-alignment, and application in a low-cost full screenprinting technology are the main advantages of the proposed process.
In the framework of the Low Emittance Gun (LEG) project, high gradient acceleration of a low emittance electron beam will be necessary. In order to achieve this acceleration, a -500 kV, 250 ns FWHM, pulse will be applied between two electrodes. Those electrodes should sustain the pulsed field without arcing, must not outgas and must not emit electrons. Ion back bombardment, and dark current will be damaging to the electron source as well as for the low emittance beam. Electrodes of commercially available OFE copper, aluminium, stainless steel (SS), titanium and molybdenum were tested, following different procedures including plasma glow discharge cleaning.
Average emittance data for ion beams extracted from cesium-sputter negative ion sources equipped with spherical, ellipsoidal, and cylindrical geometry cesium-surface ionizers are presented. The attributes of the respective source geometries are described in terms of their cesium ion optical properties. The results of recent measurement of the emittances of momentum-analyzed beams extracted from the ellipsoidal geometry source are also presented. These measurements indicate the presence of a species-dependent effect. The effect is believed to be attributable to differences in the energy spreads of the respective negative ion beams introduced by the sputter generation process.
Average emittance data for ion beams extracted from cesium-sputter negative ion sources equipped with spherical, ellipsoidal, and cylindrical geometry cesium-surface ionizers are presented. The attributes of the respective source geometries are described in terms of their cesium ion optical properties. The results of recent measurement of the emittances of momentum-analyzed beams extracted from the ellipsoidal geometry source are also presented. These measurements indicate the presence of a species-dependent effect. The effect is believed to be attributable to differences in the energy spreads of the respective negative ion beams introduced by the sputter generation process. 11 refs., 8 figs.
The inelastic scattering of the beam and the residual gas molecules in RHIC could represent one of the limitations on the beam life time and emittance growth. This report covers the dominant central nuclear collisions influence on the beam lifetime and transverse emittance growth. The cross sections for the beam-gas electron radiative captures are an order of magnitude smaller. The capture cross sections include the radiative and non-radiative capture, and the capture from the electron-positron pair creation from the 'vacuum capture'.
A new scheme of the longitudinal emittance measurement for high energy negative ion beam is proposed. The energy distribution of the detached electron from the negative ions by the photodetachment process, if the photon energy is almost equal to the electron binding energy of the negative ion (=electron affinity of the atom), reflects that of the original negative ions. Therefore, by introducing the photon in a short width comparing with the bunch width of the negative ion beam, the longitudinal energy distribution of each phase of the beam, that is the longitudinal emittance, can be measured. (author).
(abridged) We present a study of stellar population of LAEs at z=4.86 in GOODS-N and its flanking field. With the publicly available IRAC data in GOODS-N and further IRAC observations in the flanking fields, we select five LAEs which are not contaminated by neighboring objects in IRAC images and construct their observed SEDs with I_c, z', IRAC 3.6micron, and 4.5micron band photometry. The SEDs cover the rest-frame UV to optical wavelengths. We derive stellar masses, ages, color excesses, and star formation rates of five LAEs using SED fitting method. Assuming the constant star formation history, we find that the stellar masses range from 10^8 to $10^{10} Msun with the median value of 2.5x10^9 Msun. The derived ages range from very young ages (7.4 Myr) to 437 Myr with a median age of 25 Myr. The color excess E(B-V) are between 0.1-0.4 mag. Star formation rates are 55-209 Msun/yr. A comparison of the stellar populations is made between three LAEs and 88 LBGs selected ...
Nanocrystalline ZnO films were fabricated via a simple method involving the oxidation of Zn films at a remarkably low temperature of 380 C. X-ray diffraction study confirmed that the Zn films were completely oxidized even at the low temperature of 380 C and the ZnO films fabricated were of polycrystalline wurtzite structure. Room temperature optical pumping using a frequency-quintupled Q-switched Nd:YAG laser ({lambda}=213 nm) exhibited that sharp peaks at around 3.12 eV emerged above excitation powers of {proportional_to}7 MW/cm{sup 2}, demonstrating lasing in the ZnO films. These results represent that the process is a simple, promising approach for fabricating ZnO of sufficient optical performance for use as ultraviolet (UV) light emitters and an alternative UV laser source; both are key components in short-wavelength photonic devices. (orig.)
A technique is proposed to generate electron beam with ultralow transverse emittance through laser assisted transverse-to-longitudinal emittance exchange. In the scheme a laser operating in the TEM10 mode is used to interact with the electron beam in a dispersive region and to initiate the emittance exchange. It is shown that with the proposed technique one can significantly downsize an x-ray free electron laser (FEL), which may greatly extend the availability of these light sources. A hard x-ray FEL operating at 1.5 {angstrom} with a saturation length within 30 meters using a 3.8 GeV electron beam is shown to be practically feasible.
A laboratory model of a TPV generator in the kilowatt range was developed and tested. It was based on methane/oxygen combustion and a spectrally matched selective emitter/collector pair (ytterbia emitter-silicon PV cell). The system demonstrated a power output of 2.4 kilowatts at an overall efficiency of 4.5{percent} without recuperation of heat from the exhaust gases. Key aspects of the effort include: (1) process development and fabrication of mechanically strong selective emitter ceramic textile materials; (2) design of a stirred reactor emitter/burner capable of handling up to 175,000 Btu/hr fuel flows; (3) support to the developer of the production silicon concentrator cells capable of withstanding TPV environments; (4) assessing the apparent temperature exponent of selective emitters; and (5) determining that the remaining generator efficiency improvements are readily defined ...
Thermophotovoltaic (TPV) converters were developed and tested at the heat source operating temperature of 1,700 K. Rare-earth-doped yttrium aluminum garnet (YAG) and lutetium yttrium aluminum garnet (Lu, YAG) selective emitters, as well as a blackbody emitter, were coupled to InGaAs/InP photovoltaic (PV) cells and bandpass/infrared (IR) reflector filters. YAG-based selective emitters were adopted with Ho, Tm, and Er. PV cells had bandgaps of 0.51, 0.57, and 0.69 eV. Converter energy conversion efficiencies approaching 30%, as well as electrical output power densities near 2 W/cm{sup 2} were demonstrated. The overall performance of the filtered blackbody-based converter was found to be superior to the selective emitter YAG-based converters. The details of the measurements performed on the above converters and their individual components are presented.
A technique for the measurement of the total hemispherical emittance of pipe surfaces is described, and design and operational details are given. The technique is conceptually simple. A long test pipe (e.g., 3.4 m) is mounted concentrically inside a Pyrex glass pipe. The system is evacuated, and the test pipe is heated by means of an electrical resistance heater. Heat transfer from the test pipe to the enclosure is almost solely radiative, allowing an average emittance for the test pipe and the Pyrex pipe and the electrical power input to the heater. By varying the electrical power level, one can measure the test pipe emittance as a function of temperature. By using a simple correction to account for the finite length of the test pipe, one can calculate the results using the simple expression for infinite, concentric cylinders. Results agree with measurements by reflectance techniques and have a nominal relative error of ...
We studied whether plasma-etching techniques can use standard screen-printed gridlines as etch masks to form self-aligned, patterned-emitter profiles on multicrystalline-silicon (mc-Si) cells from Solarex. We conducted an investigation of plasma deposition and etching processes on full-size mc-Si cells processed in commercial production lines, so that any improvements obtained would be immediately relevant to the PV industry. This investigation determined that reactive ion etching (RIE) is compatible with using standard, commercial, screen-printed gridlines as etch masks to form self-aligned, selectively doped emitter profiles. This process results in reduced gridline contact resistance when followed by plasma-enhanced chemical vapor deposition (PECVD) treatments, an undamaged emitter surface easily passivated by plasma-nitride, and a less heavily doped emitter between gridlines for reduced ...
This document describes measurements of the directional spectral emittance of four ceramic mold materials. The work was performed with the samples at {approximately} 900{degree}C in a vacuum vessel pumped to {approximately}3 {times} 10{sup {minus}6}Torr. Results conform to expectations derived from prior work done with similar samples.
Personal monitoring and dose assessment of all radiation workers is an essential regulatory requirement as per radiation safety procedures of AERB and operating stations. The occupational workers of TAPS 1 and 2 and TAPS 3 and 4 are monitored for internal contamination due to high energy gamma emitters by whole body counting
The advance in the analysis of very small amount (<= 1#alpha#/cm"2h) of #alpha#-emitters in the cited materials is reviewed. The review, for which 75 references are listed, covers the period from January, 1978, to June, 1982. The use of #alpha#-ray counting, #alpha#-ray spectrometry, #gamma#-ray spectrometry, neutron activation analysis and mass spectrometry is discussed, and their relative merit and limitation are outlined. (J.P.N.).
The emittance of aluminum components exposed to low-temperature aqueous solutions were required for thermal analysis of a Loss of Cooling Accident for the Savannah River Site production reactors. Experimental data for the thickness and emittance of oxide films formed under these conditions were collected and reviewed. Correlations were developed for the oxide film thickness and corresponding total hemispherical emittance. Film thickness and emittance were also measured for the specific conditions of interest in order to verify the predictions based on the literature data. After one year of exposure in 30deg C reactor moderator, the aluminum oxide film thickness is predicted to be 6.4 [mu]m[+-]10%; this value is relatively insensitive to exposure time. Some phenomena which would tend to yield thicker oxide films in the reactor environment relative to those obtained under experimental conditions were ...
The emittance of aluminum components exposed to low-temperature aqueous solutions were required for thermal analysis of a Loss of Cooling Accident for the Savannah River Site production reactors. Experimental data for the thickness and emittance of oxide films formed under these conditions were collected and reviewed. Correlations were developed for the oxide film thickness and corresponding total hemispherical emittance. Film thickness and emittance were also measured for the specific conditions of interest in order to verify the predictions based on the literature data. After one year of exposure in 30deg C reactor moderator, the aluminum oxide film thickness is predicted to be 6.4 #mu#m#+-#10%; this value is relatively insensitive to exposure time. Some phenomena which would tend to yield thicker oxide films in the reactor environment relative to those obtained under experimental conditions were ...
This study is devoted to the formation of high-low-level-doped selective emitter for crystalline silicon solar cells for photovoltaic application. We report here the formation of porous silicon under chemical reaction condition. The chemical mixture containing hydrofluoric and nitric acid, with de-ionized water, was used to make porous on the half of the silicon surface of size 125 x 125 cm. Porous and non-porous areas each share half of the whole silicon surface. H{sub 3}PO{sub 4}:methanol gives the best deposited layer with acceptable adherence and uniformity on the non-porous and porous areas of the silicon surface to get high- and low-level-doped regions. The volume concentration of H{sub 3}PO{sub 4} does not exceed 10% of the total volume emulsion. Phosphoric acid was used as an n-type doping source to make emitter for silicon solar cells. The measured emitter sheet resistances at the high- and low-level-doped regions ...
The total hemispherical emittance of an oxide film that formed on 6061-T6 aluminium alloy parts in the Tower Shielding Reactor-II at Oak Ridge National Laboratory was measured from 295 to 773 K using an emissometer and/or a calorimeter. The emittance of this film was critically needed for heat transfer calculations in a simulated loss-of-coolant accident of the reactor. X-ray diffraction analysis identified the film as boehmite (Al{sub 2}O{sub 3} {times} H{sub 2}O), which dehydrated to alumina (Al{sub 2}O{sub 3}) upon heating above 473 K. The measured emittances for the alumina film are in excellent agreement with published values for anodized aluminum films and for bulk alumina. Published values of the emittance of boehmite could not be found for comparison, but evidence is presented that some anodization processes for aluminum yield boehmite and not alumina films.
This paper describes how confidence intervals can be calculated for radiofrequency emitter position estimates based on time-of-arrival and frequency-of-arrival measurements taken at several satellites. These confidence intervals take the form of 50th and 95th percentile circles and ellipses to convey horizontal error and linear intervals to give vertical error. We consider both cases where an assumed altitude is and is not used. Analysis of velocity errors is also considered. We derive confidence intervals for horizontal velocity magnitude and direction including the case where the emitter velocity is assumed to be purely horizontal, i.e., parallel to the ellipsoid. Additionally, we derive an algorithm that we use to combine multiple position fixes to reduce location error. The algorithm uses all available data, after more than one location estimate for an emitter has been made, in a mathematically optimal way.
We find dosage of gamma emitters radionuclides of samples collected in the environment of the Chinon nuclear power plant for 2002 and 2003, these results are presented in two tables: concentrations in gamma emitter radionuclides of samples collected in the terrestrial environment (soils) and aquatic environment (sediments) of the site of Chinon in june 2002 in the frame of the annual surveillance, the second table concerns the concentrations in gamma emitter radionuclides of samples collected in the terrestrial environment (soils and lichens) of the site of Chinon in may 2003 in the frame of the annual surveillance. We find also the dosage of free tritium in the water of the Loire river for 2002 and 2003, upstream and downstream to the power plant of Chinon. (N.C.)
The photoluminescence intensity of an optical emitter changes when placed in close proximity to a noble-metal nanoparticle, due to two contributions. First, the optical near-field of the nanoparticle leads to a change in excitation rate of the emitter. Secondly, the emission efficiency is changed due to an optical energy transfer from the emitter to the metal nanoparticle, which provides additional radiative and non-radiative decay channels. In this work we investigate the photoluminescence of Sm{sup 3+} ions, which are embedded in SiO{sub 2}. The photoluminescence spectrum of ions in proximity to single silver and gold nanoparticles is measured. The influence of the spectral position of the nanoparticle plasmon peak on the photoluminescence yield will be discussed and compared with model calculations.
Thermophotovoltaic energy conversion achieves direct conversion of thermal energy to electricity without the need for complex dynamic machinery operating in one of several possible thermodynamic cycles. This paper presents an analysis of a hybrid solar thermophotovoltaic (STPV) energy conversion system in which a receiver/photovoltaic (PV) array subsystem is powered by either a solar concentrator or a fossil fuel combustion source. The overall TPV system efficiency is calculated using an appropriate selective emitter and a spectrally tuned solar cell designed to achieve maximum conversion efficiency in the narrow band emitted by the selective emitter. Two limiting cases are examined to place upper and lower bounds on system performance. The estimates of system performance are based on actual experimental data from PV cells and selective emitters.
We have developed efficient spectrally selective infrared (IR) emitters that can be utilized for thermophotovoltaic (TPV) power generation by using stainless steel (SUS304) substrates coated with b- FeSi2 thin films. To develop spectrally selective emitters, we theoretically propose antireflection (AR) coatings consisting of a single layer of a dielectric material having a high refractive index (~5) and are appropriate for use with metals such as stainless steels in the IR region. This type of AR coating is fabricated by sputtering a b- FeSi2 thin film on a polished SUS304 substrate. The reflectance in the IR region is successfully reduced to less than 10%. In addition, the AR properties are stable even at 700 K in air. Therefore, metals with AR coatings of b- FeSi2 can be applied to IR em...
Accelerator concepts for heavy-ion fusion require small emittance, high-current beams. Such applications could include funnels in which high-current, like-charged particle beams are interlaced to double beam current while retaining small emittances. The first experimental demonstration confirming the beam dynamics of the funnel principle was recently completed at Los Alamos National Laboratory. A single-leg prototype 5-MeV, H{sup {minus}} funnel was successfully tested. This single-beam demonstration explored physics issues of a two-beam funnel. It contained elements for emittance control, position control, and rf deflection, as well as diagnostics for measurement of beam intensity, position and angle centroids, energy and phase centroids, and transverse and longitudinal phase-space distributions. Results of the experiment will be presented along with comparisons to simulations. 7 refs., 5 figs.
The paper generalizes some results of the United States/Moldova program on advanced composite organic and semiconductor light emitters. High density exciton system bound to N impurity superlattice grown by modern technologies and GaP:N, GaP:N:Sm nanocrystals distributed in transparent fluorine-containing polymers will be used as the base elements for new generation of optoelectronic devices. The work seeks to expand further the applications of GaP itself through the formation of nanocomposites. Classic and new methods are applied for preparation of GaP:N nanoparticles with the controlled dimensions developed clear quantum confinement effect. The long-term ordered bulk GaP crystals as well as their nanoparticles have been investigated by TEM, XRD, Raman scattering, and luminescent methods. The evolution of the Raman Light Scattering and luminescence spectra is reported from pure and doped GaP single crystals grown over 40 ...
We report the first quantitative assessment of electrosprayed droplet/ion focusing enabled by the use of a voltage-assisted air amplifier between an electrospray ionization emitter and a hybrid...Full Text Available
Transport of negative ion beams through plasma is reviewed. The effect of space charge on beam stability and beam emittance is discussed. The approaches to the beam transport problem developed at Los Alamos, Berkeley, Oak Ridge and Culham Laboratory are intercompared. (AIP)
Additional results using a calorimetric technique for measuring the total hemispherical emittance of pipe surfaces from 400 to 600 K are described. Two different Pyrex pipe enclosures were used, one of 15 cm i.d. and the other of 30 cm i.d. An error analysis showed that the larger diameter Pyrex pipe should have a smaller error, but the difference was negligible for the 4.4-cm test pipe diameter used. Measurements on a short length of a previously-measured pipe agreed with earlier measurements, but only over the temperature range of the measurements. While the technique normally uses a vacuum to minimize nonradiative heat transfer, measurements were done succesfully with an argon atmosphere in a closed system. A nickel-plated pipe, measured first in a vacuum and then in an argon atmosphere, allowed calculation of an effective convective heat-transfer coefficient for use with test pipes of unknown emittances. Measurements done with an atmosphere ...
The National Bureau of Standards' (NBS) CW racetrack microtron (RTM) will be utilized as a driver for a free electron laser (FEL) oscillator. The NBS RTM possesses many exceptional properties of value for the FEL: i) CW operation, ii) energy from 20-185 MeV, iii) small energy spread and emittance, iv) excellent energy stability, and v) high average power. The 1-D FEL gain formula predicts that the FEL would oscillate at the fundamental approximately from 0.25 #mu#m to 10 #mu#m when up-grading the peak current to #>=# 2 A. In this paper, the authors present 3-D self-consistent numerical results including several realistic effects, such as emittance, betatron oscillations, diffraction and refraction. The results indicate that the design value of the transverse emittance is small enough that it does not degrade the FEL performance for intermediate to long wavelengths, and only slightly degrades the performance at the ...
We consider the spin-up of the white dwarf in non-magnetic cataclysmic variables (CVs) during secular evolution. If this is unresisted, CVs are quenched as boundary-layer emitters once the binary period has decreased by #approx# 1 hr. Angular momentum loss in nova explosions may, however, prevent the star reaching breakup. If the explosions remove (1 + #epsilon#) x the mass accreted between outbursts, values 0.5 < #approx# #epsilon# < #approx# 1 allow CVs to be modest boundary-layer emitters for most of their lifetimes. Spectral effects will limit their detection as soft X-ray sources. (author).
Power supply ripple at frequencies of 720 Hz and its harmonies is expected to affect the motion of particles in the collider. These ripple frequencies are nearly resonant with the betatron frequencies. To estimate the tolerable ripple levels, we have tracked particles through the complete nonlinear lattice for 10[sup 4] turns with ripple fed from 10 different power stations and including up to 7 different ripple frequencies. We presently estimate that relative ripple amplitudes must be below the 10[sup 8] level for there to be no significant impact on the emittance over the short term.
Power supply ripple at frequencies of 720 Hz and its harmonies is expected to affect the motion of particles in the collider. These ripple frequencies are nearly resonant with the betatron frequencies. To estimate the tolerable ripple levels, we have tracked particles through the complete nonlinear lattice for 10{sup 4} turns with ripple fed from 10 different power stations and including up to 7 different ripple frequencies. We presently estimate that relative ripple amplitudes must be below the 10{sup 8} level for there to be no significant impact on the emittance over the short term.
Peatlands are an important long-term sink for atmospheric carbon dioxide (CO{sub 2}). The storage function of peatland ecosystems is significantly impacted by drainage and extraction processes, which can result in the release of significant amounts of CO{sub 2}. This paper investigated the net ecosystem CO{sub 2} exchange of a newly developed extraction-restoration technique that preserved the acrotelm and replaced it directly on the cut surface of the peatlands. The technique used a modified block-cut method with a back-hoe to create a drainage ditch. Actrotelm and surface vegetation were removed and placed to one side, and the peat was mechanically removed. The acrotelm was then transplanted over the older and more decomposed catotelm peat to create a trench topography in which the natural peatland was higher than the extracted zone. Air temperatures, water table levels, and volumetric moisture content levels were measured throughout the experiment. Measurements ...
I present an exact calculation of free-electron-laser (FEL) eigenmodes (fundamental as well as higher order modes) in the exponential-gain regime. These eigenmodes specify transverse profiles and exponential growth rates of the laser field, and they are self-consistent solutions of the coupled Maxwell-Vlasov equations describing the FEL interaction taking into account the effects due to energy spread, emittance and betatron oscillations of the electron beam, and diffraction and guiding of the laser field. The unperturbed electron distribution is assumed to be of Gaussian shape in four dimensional transverse phase space and in the energy variable, but uniform in longitudinal coordinate. The focusing of the electron beam is assumed to be matched to the natural wiggler focusing in both transverse planes. With these assumptions the eigenvalue problem can be reduced to a numerically manageable integral equation and solved exactly with a kernel iteration ...
Primary standardisation was performed on a solution of "1"8F using the 4#pi##beta#-#gamma# coincidence counting efficiency-tracing extrapolation method with "6"0Co used as a tracer nuclide. The result was used to calibrate the ANSTO secondary standard ionisation chamber which is used to disseminate Australian activity standards for gamma emitters. Using the secondary activity standard for "1"8F, the Capintec CRC-712M dose calibrator at the Australian National Medical Cyclotron (NMC) Positron Emission Tomography (PET) Quality Control (QC) Section was calibrated. The dial setting number recommended by the manufacturer for the measurement of the activity of "1"8F is 439. In this work, the dial setting numbers for the activity measurement of the solution of "1"8F in Wheaton vials were experimentally determined to be 443+/-12, 446+/-12, 459+/-11, 473+/-15 for 0.1, 1, 4.5 and 9ml solution volumes, respectively. The uncertainties given above are ...
Aim: Compounds such "9"9"mTc-MDP and "9"9"mTc-HEDP are used regularly in bone scintigraphy for metastasis detection. The therapeutics properties of beta emitter radionuclides like "1"5"3Sm, "1"6"6Ho and "1"7"7Lu has been widely reported in literature being "1"7"7Lu the less developed for medical applications. With the purpose of study different radiopharmaceuticals alternatives, for metastasis bone palliation, we have evaluated, on a comparative basis, the labeling of "1"5"3Sm-MDP, "1"5"3Sm-HEDP, "1"6"6Ho-MDP, "1"6"6Ho-HEDP, "1"7"7Lu-MDP and "1"7"7Lu-HEDP from the exhibited radionuclidic purity and biological distribution point of view. Material and Methods: The radionuclides were produced at La Reina Research Reactor, Chilean Nuclear Energy Commission. The radionuclidic purity was determined by gamma-Ray spectrometry. The labeling was accomplished with MDP (Plenum) and HEDP synthesized in-house. The in-vitro affinity of labeled compounds to ...
An embodiment of a mercury-free fluorescent lamp combines a low pressure rare gas discharges with a phosphor having a quantum efficiency grater than one. The choice of the rare gas depends on a number of factors, one of which is the resonance transition energy. Less demand is placed the quantum efficiency of the phosphor for a lower energy resonance photon. Xenon has the lowest energy resonance transition of the stable rare gases at 8.5 eV (147 nm) and thus is a good candidate to study. The usefulness of a xenon-based discharge depends on the radiant emittance of the discharge at the resonance wavelength of 147 nm. The radiant emittance from a low pressure xenon positive column discharge is measured using two independent techniques. The first relies on the measurement of the resonance level density using absorption techniques. The effective decay rate of the resonance level is calculated using radiation trapping theory. The product of this ...
The dependencies that limit high frequency operation of a vacuum microelectronic grating free-electron laser are examined. The important parameters are identified as the electron beam energy, emittance, and generalized perveance. The scaling of power with emittance and frequency is studied in the far-infrared spectral range using a modified scanning electron microscope (SEM) and submillimeter diffraction gratings. The SEM is suited to the task of generating and positioning a low emittance (10"-"2#pi#-mm-mrad), low current (100 #mu#A), but high current density (50-500 A cm"-"2) electron beam. It has been used to demonstrate the spontaneous emission process known as the Smith-Purcell effect. A vacuum microelectronic grating free-electron laser has the potential of generating radiation throughout the entire far-infrared spectral range which extends from approximately 10 to 10"3#mu#m. An introduction to the theory, initial ...
By applying lock-in thermography imaging, light-beam-induced current imaging, electron-beam-induced current imaging at different stages of sample preparation, and infrared light microscopy in transmission mode, the physical nature of the dominant material-induced shunts in multicrystalline solar cells made from p-type silicon material has been investigated. It turns out that these shunts are due to silicon carbide (SiC) filaments, which grow preferentially in grain boundaries and cross the whole cell. These filaments are highly n-type doped, like the emitter layer on the surface of the cells. They are electrically connected both with the emitter and with the back contact, thereby producing internal shunts in the solar cell.
By applying lock-in thermography imaging, light-beam-induced current imaging, electron-beam-induced current imaging at different stages of sample preparation, and infrared light microscopy in transmission mode, the physical nature of the dominant material-induced shunts in multicrystalline solar cells made from p-type silicon material has been investigated. It turns out that these shunts are due to silicon carbide (SiC) filaments, which grow preferentially in grain boundaries and cross the whole cell. These filaments are highly n-type doped, like the emitter layer on the surface of the cells. They are electrically connected both with the emitter and with the back contact, thereby producing internal shunts in the solar cell.
By applying lock-in thermography imaging, light-beam-induced current imaging, electron-beam-induced current imaging at different stages of sample preparation, and infrared light microscopy in transmission mode, the physical nature of the dominant material-induced shunts in multicrystalline solar cells made from p-type silicon material has been investigated. It turns out that these shunts are due to silicon carbide (SiC) filaments, which grow preferentially in grain boundaries and cross the whole cell. These filaments are highly n-type doped, like the emitter layer on the surface of the cells. They are electrically connected both with the emitter and with the back contact, thereby producing internal shunts in the solar cell.
The operational limits of the Tower Shielding Reactor-2 (TSR-2) have been revised to account for placing the reactor in a beam shield, which reduces convection cooling during a loss-of-coolant accident (LOCA). A detailed heat transfer analysis was performed to set operating time limits which preclude fuel damage during a LOCA. Since a LOCA is survivable, the pressure boundary need not be safety related, minimizing seismic and inspection requirements. Measurements of reactor component emittance for this analysis revealed that aluminum oxidized in water may have emittance much higher than accepted values, allowing higher operating limits than were originally expected. These limits could be increased further with analytical or hardware improvements. 5 refs., 7 figs.
A 150 Watt thermophotovoltaic (TPV) power generator is being developed. The technical approach taken in the design focused on optimizing the integrated performance of the primary subsystems in order to yield high energy conversion efficiency and cost effectiveness. An important aspect of the approach is the use of a selective emitter radiating to a bandgap matched photovoltaic array to minimize thermal and optical recuperation requirements, as well as the non-recoverable heat losses. For the initial prototype system, fibrous ytterbia emitters radiating in a band centered at 980 nm are matched with high efficiency silicon photoconverters. The integrated system includes a dielectric stack filter for optical energy recovery and a ceramic recuperator for thermal energy recovery. The system has been operated with air preheat temperatures up to 1350K. The design of the system and development status are presented. {copyright} {ital 1997 American ...
One of the major challenges facing the proposed high-energy linear e^+e^ colliders is the preservation of the extremely small vertical emittance from the damping rings to the interaction point (IP). This emittance must be transported through bunch compression sections, the main linac and finally through the beam delivery system to the IP. Historically, the beam dynamics issues of each subsystem have been studied quasi-independently, with the beam conditions and tolerances being specified at the boundaries. As part of the recent International Linear Collider Technical Review Committee, new simulation tools have been developed to simulate the beam transport through the integrated system, including static and dynamic errors, stabilization systems, and tuning algorithms.
A process for separation of actinides and technetium from reprocessing high level liquid waste has been developed, the CTH-process. The main parts are three consecutive solvent extraction cycles followed by an optional step for sorption on inorganic ion exchangers. The first extraction cycle removes and recovers uranium, neptunium, and plutonium by extraction with HDEHP. The second extraction cycle separates technetium and nitric acid from the waste using TBP. In the third extraction cycle Am and Cm are separated from the waste using HDEHP. The actinide free waste is then passed through inorganic ion exchangers to remove most of remaining radionuclides. The process has been tested on an authenic HLLW solution. A decontamination factor > 10/sup 5/ for alpha emitters was measured for the solvent extraction process and the sorption on inorganic ion exchangers gave a decontamination factor > 3x10/sup 4/ for beta emitters.
One requirement of a thermophotovoltaic (TPV) radiator is to efficiently emit photons at high temperatures to TPV cells for conversion to electric power. Because many candidate radiator materials with adequate structural properties display low emissivity, coatings or other surface modifications are required for enhancement of emissivity. Six plasma sprayed coatings and one textured surface demonstrated adequate thermal stability and emittance values of 0.8 or greater. Promising attributes of modified surfaces are identified.
A new optics providing an emittance close to the minimum theoretical value has been proposed for the Super-ACO storage ring with a reduced value of the momentum compaction factor and non-zero dispersive function in the Free-Electron Laser (FEL) section. It has been adapted to the FEL operation mode, with two RF cavities at 100 and 500 MHz. The obtained results concerning this new optics and the FEL oscillation are presented.
In this note we describe a conceptual design of a part ofthe electron beam delivery system for FERMI@Elettra free electron laser(FEL) located between the end of the linac and the entrance to the FEL.This part includes the emittance diagnostic section, the electron beamswitchyard for two FELs called spreader and matching sections. The designmeets various constrains imposed by the existing and planned buildingboundaries, desire for utilization of existing equipment and demands forvarious diagnostic instruments.
2D MEDICI simulator is used to investigate hardening solutions to single-event burnout (SEB). SEB parametric dependencies such as carrier lifetime reduction, base enlargement, and emitter doping decrease have been verified and a p"+ plug modification approach for SEB hardening of power MOSFETs is validated with simulations on actual device structures.
A near-field microscope which operates in the rf/microwave frequency range is described. In this microscope, a scanning tunneling microscope (STM)-like tip rather than an aperture is used as a point-like evanescent field emitter. A spatial resolution of {approximately}5 {mu}m ({approximately}{lambda}/100000) is achieved in the current version. The design of the microscope as well as the principal factors which affect its performance are discussed. {copyright} {ital 1996 American Institute of Physics.}
Random motion of a particle, emitting and absorbing tachyons, is investigated. It is shown that if bradyon is in equilibrium with neutral gas, i.e. it absorbs and emits tachyons, which do not have any charges, tha particle with each absorption-emittance of a tachyon changes its energy and momentum, never varying its own mass, and as a result it moves like a brownian particle. Thus, bradyon, interacting with tachyon gas, increases its momentum continuously in agreement with the Einstein-Fokker-Planck type equation.
Focused ion beam (FIB) systems prove to be useful precision micromachining tools for a wide variety of applications. This micromachining technique includes scanning ion microscopy (SIM), micromachining by physical sputtering, and the ion-beam induced surface chemistry for etching and deposition. This technique is applied to image and modify IC's, to micromechanical applications, to modify the tip shape of tungsten emitters, and to prepare cross sections of selected regions for inspection in a transmission electron microscope (TEM). (orig.)
This book brings recommendations and information on the choice and the operating of heating systems and domestic hot water production in order to better choose the house, to better use the heating and to preserve the environment. General notions on the different heating systems and their operating on the renewable energies used and the heating emitters offer advices for the purchase of a house. (A.L.B.)
Characterization of the electron beam's properties will be a major task after the upgrade of the Los Alamos Free-Electron Laser (FEL) Facility with a photoelectric injector (PEI) and increased acceleration capability to 40 MeV. Adjustments to the previous diagnostics package that address the lower beam emittance, higher energy, and wakefield source reduction issues will be discussed. 6 refs., 8 figs., 1 tab.
Stabilization of the particle beam position with respect to the focusing optics in the third generation synchrotron light sources is crucial to achieving low emittance and high brightness. For this purpose, global and local beam orbit correction feedbacks will be implemented in the APS storage ring. In this article, the authors discuss application of digital signal processing to particle/photon beam position feedback using the PID (proportional, integral, and derivative) control algorithm.
The report describes the studies carried out to design a non-destructive system for the radiological characterization of packages containing LLW and MLW. This technique is applied for quantitative and qualitative gamma emitters determination in packages with homogeneous and heterogeneous matrices as well as the development of a maximum activity points location system. Development involves also the automatization for its industrial use.
Accelerated aging tests on tin-oxide-coated anodized aluminium selective absorber surfaces have been performed. It is shown that the tin oxide layer provides excellent protection for the anodized surface. The thermal stability of the double layer is equal to, or better than, the stability of the bare anodized surface. Both surfaces degrade very slowly at 450deg C. The anodic layer is porous and therefore not very scratch resistant and it degrades when exposed to humidity, both acidic and alcaline. It is shown that the tin oxide film, which is hard and chemically very stable, almost completely protects the anodized surface from chemical degradation. The mechanical wear resistance is also considerably improved. The optical selectivity does not quite match that of the the anodized surface, but the remarkable stability together with the solar parameters of {alpha}=0.91 and hemispherical emittance {epsilon}= 0.16 (normal emittance {epsilon}{sub ...
A helical cooling channel (HCC) has been proposed to quickly reduce the six-dimensional phase space of muon beams for muon colliders, neutrino factories, and intense muon sources. The HCC is composed of a series of RF cavities filled with dense hydrogen gas that acts as the energy absorber for ionization cooling and suppresses RF breakdown in the cavities. Magnetic solenoidal, helical dipole, and helical quadrupole coils outside of the RF cavities provide the focusing and dispersion needed for the emittance exchange for the beam as it follows a helical equilibrium orbit down the HCC. In the work presented here, two Monte Carlo programs have been developed to simulate a HCC to compare with the analytic predictions and to begin the process of optimizing practical designs that could be built in the near future. We discuss the programs, the comparisons with the analytical theory, and the prospects for a HCC design with the capability to reduce the six-dimensional phase ...
The traditional view that Ly-alpha emission and dust should be mutually exclusive has been questioned more and more often, notably the observations of Ly-alpha emission from ULIRGs seems to counter this view. In this paper we seek to address the reverse question: How large a fraction of Ly-alpha selected galaxies are ULIRGs? Using two samples of 24/25 Ly-alpha emitting galaxies at z = 0.3/2.3 we perform this test, also including results at z = 3.1, and find that whereas the ULIRG fraction at z = 3.1 is very small, it systematically increases towards lower redshifts. There is a hint that this evolution may be quite sudden and that it happens around a redshift of z ~ 2.5. Measuring the infrared luminosities of the Ly-alpha emitters, we find that they are in the normal to ULIRG range in the lower redshift sample, whereas the higher redshift galaxies all have luminosities in the ULIRG category. The Ly-alpha escape fractions for these infrared bright galaxies are in the ...
We construct a sample of low-redshift Ly-alpha emission-line selected sources from GALEX grism spectroscopy of nine deep fields to study the role of Ly-alpha emission in galaxy populations with cosmic time. Our final sample consists of 122 (142) sources selected in the redshift interval z=0.195-0.44 (z=0.65-1.25) from the FUV (NUV) channel. We classify the Ly-alpha sources as AGNs if high-ionization emission lines are present in their UV spectra and as galaxies otherwise. These classifications are broadly supported by comparisons with X-ray and optical spectroscopic observations. We classify additional sources as AGNs using line widths for our Ly-alpha emitter (LAE) analysis. Defining the GALEX LAE sample in the same way as high-redshift LAE samples, we show that LAEs constitute only about 5% of NUV-continuum selected galaxies at z~0.3. We also show that they are less common at z~0.3 than they are at z~3. We find that the z~0.3 optically-confirmed Ly-alpha galaxies ...
The Holifield Radioactive Ion Beam Facility (HRIBF) now under construction at the Oak Ridge National Laboratory will use the 25-MV tandem accelerator for the acceleration of radioactive ion beams to energies appropriate for research in nuclear physics; negative ion beams are, therefore, required for injection into the tandem accelerator. Because charge exchange is an efficient means for converting initially positive ion beams to negative ion beams, both positive and negative ion sources are viable options for use at the facility; the choice of the type of ion source will depend on the overall efficiency for generating the radioactive species of interest. A high-temperature version of the CERN-ISOLDE positive ion source has been selected and a modified version of the source designed and fabricated for initial use at the HRIBF because of its low emittance, relatively high ionization efficiencies and species versatility, and because it has been engineered for remote ...
The Holifield Radioactive Ion Beam Facility (HRIBF) now under construction at the Oak Ridge National Laboratory will use the 25-MV tandem accelerator for the acceleration of radioactive ion beams to energies appropriate for research in nuclear physics; negative ion beams are, therefore, required for injection into the tandem accelerator. Because charge exchange is an efficient means for converting initially positive ion beams to negative ion beams, both positive and negative ion sources are viable options for use at the facility; the choice of the type of ion source will depend on the overall efficiency for generating the radioactive species of interest. A high-temperature version of the CERN-ISOLDE positive ion source has been selected and a modified version of the source designed and fabricated for initial use at the HRIBF because of its low emittance, relatively high ionization efficiencies and species versatility, and because it has been engineered for remote ...
For many years, {beta} radioactivity has been used to label molecules and follow them in various biological processes. {beta} imaging is obtained by autoradiography. Classically made on films or on photographic emulsions, autoradiography is now supplanted by radio-imagers which are very performing. The phosphor-imager, {beta}-imager and {mu}-imager are the systems mainly used today and their operating principles and properties are compared. The great advantages of these imagers are: their rapidity to obtain results and their reliability for absolute quantification. All emitters ({beta}{sup -}, {beta}{sup -} -{gamma} and {beta}{sup +}) are detectable as well as the gamma emitters of nuclear medicine, by means of their low energy electrons ejected during y emission. Phosphor-imager is well suited to energetic tracers and large series of experiments. Real time radio-imagers ({beta}-imager and {mu}-imager) are preferred to verify experimental ...
The flux distributions and enhancement factors for various gas doser designs typically used in surface science applications and chemisorption studies have been calculated and compared. The following conclusions, which will aid the experimentalist in the choice of doser design, can be made. (1) The enhancement factor expected for a given doser can easily be derived from Fig. 2. (2) The optimum doser design is a multichannel array with a radius slightly larger than that of the sample, and a distance from the sample < 10% of the sample diameter. (Complications of this design are discussed.) (3) Because of space requirements, the sample--doser distance must sometime be > or =40% of the sample diameter, in which cases it is better to use a cosine emitter. A good, very simple doser design is described that consists of a small cosine emitter with a sample--doser distance of 1/2 the sample diameter. This provides an enhancement factor >50% of ...
The Neutron Science Project at Japan Atomic Energy Research Institute has been proposed for the research of nuclear transmutation technology and the basic science with a spallation neutron source. The project calls for an 8MW proton linac which accelerates 5.3mA average current cw and pulsed beams up to 1.5GeV. The superconducting (SC) rf-cavity is the main option for the energy part from 100MeV to 1.5GeV because by using the SC structure, less power is consumed in cw operation than by using a normal conducting (NC) structure. A conceptual design study of the superconducting proton linac is reported. The SC linac is composed of 8 {beta} sections. Each section has the identical 5-cell cavities with the surface peak field of 16MV/m. The total number of cavities is 284, and the length of the SC linac is 690m. The lattice design is determined with the equipartitioned condition and the matched envelope equations for the minimum emittance growth. The transverse and ...
The description and results of the study on the free-electron laser (FEL) on 100 #mu#m, representing the first line of the FIAN multipurpose radiation complex, are presented. The electron beam with the energy of 6-8 MeV, once accelerated in a racetrack microtron and extracted into the FEL injection tract, is used for exciting this FEL. The system of the electron beam transport, injection and diagnostics are described. Additional works on increasing the beam emittance up to 0.4 A for one energy spread percent are carried out. The obtained electron beam parameters assure generation of the far infrared radiation in the FEL
Two sources of negative ions are described. An rf source produces up to 14 ..mu..A beams of He/sup -/ by charge exchange in Rb vapor. The other Source of Negative Ions by Cesium Sputtering (SNICS) produces a wide variety of negative ion beams in the ..mu..A range. Two important features of SNICS are its simple, compact construction and its very good beam emittance (2 to 4..pi..mm mrad MeV/sup 1/2/). Both sources have lifetimes >200 hours and they are used extensively on the Wisconsin EN tandem.
Carrier-free "8"8Y radioisotope, which has the longest half life (T=106.6 d) of yttrium radioisotopes and is a #gamma#-ray emitter, was obtained by proton irradiation of strontium, followed by cooling for one month. Then, "8"8Y was purified by precipitating strontium as strontium nitrate and extracting yttrium with tri-n-butyl phosphate (TBP). The decontamination factor of strontium to yttrium was more than 4x10"3 and chemically pure yttrium radioisotope was obtained. (author) 6 refs.
In drift tube linacs a beam energy spread results form the finite beam size. Radial variation of the axial accelerating field induces a beam energy spread, which, in general, will accumulate as the beam passes through successive drift tubes. This paper shows that under some conditions of periodic transverse focusing and longitudinal phase focusing, the correlation between the longitudinal and transverse motion can be used to correct the energy spread. The process of achieving such a correction is first described in a simplified situation, and then demonstrated for a particular tuning using a ray-tracing program which models a low velocity and low charge state linac designed for radioactive ion beams.
A basic treatment of the principle of the linac-driven free-electron laser (FEL) is given. The first part of the paper describes the FEL in low-gain approximation, and in the second part the high-gain FEL theory is given. The majority of the treatment describes FELs in one dimensional approximation, neglecting effects by diffraction of radiation and by electron beam emittance. Only in the final section a few remarks on these issues are given. The ambition of the paper is by no means any progress in FEL theory but a clear presentation of basic FEL theory concepts with explicit derivation of the formulae from first principles. (orig.)
The ongoing upgrade of the Los Alamos Free-Electron Laser (FEL) Facility involves the addition of a photoelectric injector (PEI) and acceleration capability to about 40 MeV. The electron-beam and high-speed diagnostics provide key measurements of charge, beam position and profile, divergence emittance, energy (centroid, spread, slew, and extraction efficiency), micropulse duration, and phase stability. Preliminary results on the facility include optical transition radiation interferometer measurements of divergence (1 to 2 mrad), FEL extraction efficiency (0.6 {plus minus} 0.2%), and drive laser phase stability (< 2 ps (rms)). 10 refs.
The ongoing upgrade of the Los Alamos Free-Electron Laser (FEL) Facility involves the addition of a photoelectric injector (PEI) and acceleration capability to about 40 MeV. The electron-beam and high-speed diagnostics provide key measurements of charge, beam position and profile, divergence emittance, energy (centroid, spread, slew, and extraction efficiency), micropulse duration, and phase stability. Preliminary results on the facility include optical transition radiation interferometer measurements of divergence (1 to 2 mrad), FEL extraction efficiency (0.6 {plus_minus} 0.2%), and drive laser phase stability (< 2 ps [rms]). 10 refs.
The requirements for transporting high-current, negative-ion beams are presented with particular emphasis on applications involving negative-hydrogen-ion beams. In addition to the usual matching and steering problems, particular attention must be paid to beam emittance growth in the transport system. Depending on the application, a number of approaches have been developed using both magnetic and electric lenses. I discuss the design considerations for transporting and matching these beams to radiofrequency quadrupole accelerators, and present a survey of the various types of beamlines now used for negative-ion beams.
The requirements for transporting high-current, negative-ion beams are presented with particular emphasis on applications involving negative-hydrogen-ion beams. In addition to the usual matching and steering problems, particular attention must be paid to beam emittance growth in the transport system. Depending on the application, a number of approaches have been developed using both magnetic and electric lenses. I discuss the design considerations for transporting and matching these beams to radio-frequency quadrupole accelerators, and present a survey of the various types of beamlines now used for negative-ion beams.
The requirements for transporting high-current, negative-ion beams are presented with particular emphasis on applications involving negative-hydrogen-ion beams. In addition to the usual matching and steering problems, particular attention must be paid to beam emittance growth in the transport system. Depending on the application, a number of approaches have been developed using both magnetic and electric lenses. I discuss the design considerations for transporting and matching these beams to radiofrequency quadrupole accelerators, and present a survey of the various types of beamlines now used for negative-ion beams.
In the 1993 running cycle of the Stanford Linear Collider electron spin polarization measurements with a Moller polarimeter at the end of the linac and a Compton polarimeter near the interaction point (IP) indicated a relative polarization loss of up to 20% across the arc. We present calculations of the depolarizing effects where variations in energy, energy spread and transverse emittance as well as changes in orbit and initial spin orientation are taken into account. We compare our results with measurements and conclude that, in standard operating conditions, the relative polarization loss is only 3+/-2%.
Abstract First results showing the viability of combining laser chemical processing (LCP) and aerosol jet printing (AJP) technologies to produce a high-efficiency front side for silicon solar cells are presented. LCP simultaneously opens the anti-reflection coating (ARC) and highly dopes the underlying silicon to create a selective emitter, while AJP is the first in a two-step fine-line contact formation procedure. The electrical properties as well as the morphology of the resulting structures are presented. Performance similar to that achieved with evaporated TiPdAg metallization is demonstrated. Copyright 2010 John Wiley & Sons, Ltd.
Air pollution abatement measures are being intensified at the moment: Power plants and district heating systems are being retrofitted with high-efficiency desulphurisation and NO/sub 2/ reduction systems, the 3rd amendment of the Clean Air Technical Guide sets more rigid emission limits, and unleaded petrol and catalysts will significantly reduce car exhaust emissions. The author presents pollutant balances from 1966 to 1982 to contradict the popular notion that pollutant emitters formerly failed to take preventive measures.
The radiation properties of the #alpha# emitter "2"1"1At are in favor of its application malignant tumor therapy. As a basis for further investigations the biokinetics of At"-, At x H_2O, At I_2"-, and [At(thio)_2]"+ were determined after i.v. injection into healthy and tumor-bearing mice. The estimation of the ion mobility of the carrier-free compounds allowed the use of uniquely characterized initial compounds. The organ distribution of all species examined was similar to the distribution of astatide. Accumulation was found in the thyroid and other inner organs. (author).
We study the all-optical time-control of the strong coupling between a single cascade three-level quantum emitter and a microcavity. We find that only specific arrival-times of the control pulses succeed in switching-off the Rabi oscillations. Depending on the arrival times of control pulses, a variety of exotic non-adiabatic cavity quantum electrodynamics effects can be observed. We show that only control pulses with specific arrival times are able to suddenly switch-off and -on first-order coherence of cavity photons, without affecting their strong coupling population dynamics. Such behavior may be understood as a manifestation of quantum complementarity.
A process has been developed that exploits the characteristics of microwave heating for the vitrification of high-level radioactive liquid waste. This process, microwave vitrification, has been successfully operated at pilot plant scale in an active cell using simulated liquid waste containing several curies of radioactivity. Excellent decontamination factors have been achieved for both volatiles and nonvolatiles with an average ruthenium decontamination factor of 490 and a gross alpha emitter decontamination factor of 100,000. Almost all the radioactivity is incorporated in a glass block.
A process has been developed that exploits the characteristics of microwave heating for the vitrification of high-level radioactive liquid waste. This process, microwave vitrification, has been successfully operated at pilot plant scale in an active cell using simulated liquid waste containing several curies of radioactivity. Excellent decontamination factors have been achieved for both volatiles and nonvolatiles with an average ruthenium decontamination factor of 490 and a gross alpha emitter decontamination factor of 100,000. Almost all the radioactivity is incorporated in a glass block.
Ellipsometric studies and reflectance measurements on five anodized coloured 304 stainless steel samples (Brown, Violet, Blue, Light Grey and Dark Grey) are reported. The optical properties, solar absorptance and thermal emittance of samples have been obtained. Measured values of absorptance lay between 0.75-0.87 together with a near normal emittance value approx. =0.10 at 100/sup 0/C. The total hemispherical emittance has been measured at 100 and 200/sup 0/C for the sample having the best selective surface. This study shows that the blue coloured surface has the most favourable combination of radiation properties. The surface deteriorates at temperatures above 210/sup 0/C. Oxidation is assumed to be the deterioration mechanism. The different samples exhibited difference in the /PSI/ and ..delta.. parameters as determined by ellipsometry both before and after heat treatments. When brown and violet samples were coated with a ...
The thermophotovoltaic (TPV) option was not selected for further deep space mission technology development in NASA for several reasons. Chief among them was the large radiator required to keep the photovoltaic cells at a sufficiently low operating temperature. This led to significant integration problems with the spacecraft and limited sensor view angles. It is clear that the issue of cell temperature is crucial for space applications because of radiator size and system impact. Many efforts have focused on matching cell band gap to appropriate emitters in the 1 to 2 {mu}m range, resulting in band gaps in the 0.5 to 0.8 eV range. However, low band gaps lead to low open circuit voltages ({approximately}0.25 to 0.45 V) caused by high intrinsic carrier concentrations (n{sub i}{sup 2}). Thus, in order to obtain high performance. Photovoltaic cell temperatures must be kept near room temperature. This leads to the inevitable consequence of very large radiators for space ...
Two types of thermal control materials based on polyimide film UPILEX-R are designed. One of thermal control material R/Al is coated with Al on the back surface. The other of thermal control material TCC/R/Al is coated with transparent conductive coating on the font surface and is coated with Al on the balk surface. The solar absorptance is measured spectroscopically with an integrating sphere in the wavelength region of 0.26 - 2.50 {mu}m and the total hemispherical emittance is measured calorimetrically in the temperature range of -100-+100{degree}C for the present thermal control materials. To evaluate the space degradation of optical properties (refractive index, extinction coefficient, absorption coefficient) on UPILEX-R film and solar absorptance on thermal control materials, space environment simulation tests are performed on the ground with independent radiation and combined radiation by UV, electrons, and protons. An onboard simultaneous measurement ...
Emerging high-power microwave technologies require that bioeffects of exposure to this type of radiation be investigated for health and safety considerations. Disruption of animal behavior is reported to be a sensitive indicator of microwave exposure. Three behavioral tasks were chosen for this initial investigation of exposure to U.S. Air Force high-power microwave emitters. The tasks were: (1) single-trail avoidance, (2) water satiation, and (3) rotarod performance. Exposure to high-power microwave radiation from the USAFSAM peak-power simulator significantly affected the single-trail avoidance task. Neither the single-trail avoidance task nor rotarod performance was affected by the Gypsy emitter. However, animals exposed to 9-kW and 11-kW outputs from the USAFSAM emitter spent significantly less time imbibing water postexposure than sham-exposed animals. The most consistent finding in the animals exposed to the Gypsy ...
One of the hallmarks of linear coupling is the resonant exchange of oscillation amplitude between the horizontal and vertical planes when the difference between the unperturbed tunes is close to an integer. The standard derivation of this phenomenon (known as the difference resonance) can be found, for example, in the classic papers of Guignard [1, 2]. One starts with an uncoupled lattice and adds a linear perturbation that couples the two planes. The equations of motion are expressed in hamiltonian form. As the difference between the unperturbed tunes approaches an integer, one finds that the perturbing terms in the hamiltonian can be divided into terms that oscillate slowly and ones that oscillate rapidly. The rapidly oscillating terms are discarded or transformed to higher order with an appropriate canonical transformation. The resulting approximate hamiltonian gives equations of motion that clearly exhibit the exchange of oscillation amplitude between the two planes. If, instead of ...
In an epidemiological study of the somatic late effects risk following incorporation of a short lived #alpha#-emitter, 1473 ankylosing spondylitis patients treated with repeated intravenous injections of "2"2"4Ra in the years 1948 - 75, have been observed in the GSF. The usual therapeutic plan consisted of a total of 10 - 12 injections of 1.036 MBq (28 #mu#Ci) of "2"2"4Ra each, given at weekly intervals; this would result in an cumulative #alpha#-dose of 0.56 - 0.67 Gy to the marrow-free skeleton of a 70-kg-man (standard man). These patients have been followed together with a control group of ankylosing spondylitis patients not treated with radioactive drugs and/or X-rays. Until May 1993 (mean follow-up time 19.9 yr), 595 patients of the exposure group and 722 patients of the control group have died, causes of death have been ascertained for 578, resp. 668 patients. Among others we observed in the exposure group 10 cases of leukaemia (vs. 2.7 - 2.8 cases expected, ...
The focus of this study is on the preparatory detection of uncertain net greenhouse gas (GHG) emission changes (also termed emission signals) under the Kyoto Protocol. The crucial question to be addressed is: How well do we need to know net emissions if we want to detect a specified emission signal after a given time? No restrictions exist as to what concerns the net emitter, which may be any GHG source or sink. Annex I countries are chosen as net emitters, simply for reasons of data availability and because of the excellent possibility of comparing net emitters (inter-country comparison). The countries' emissions - in an increasing number of cases even their uncertainties - are available permitting the application of preparatory signal detection techniques, which are suited to address the aforementioned question. We currently discuss four hierarchically-ordered detection concepts to assess emission signals in a ...
Very high energy (VHE; >100 GeV) observations of a sample of selected active galactic nuclei (AGN) were performed between January 2005 and April 2007 with the High Energy Stereoscopic System (HESS), an array of imaging atmospheric-Cherenkov telescopes. Significant detections are reported elsewhere for many of these objects. Here, integral flux upper limits for twelve candidate very high energy (VHE; >100 GeV) gamma-ray emitters are presented. In addition, results from HESS observations of four known VHE-bright AGN are given although no significant signal is measured. For three of these AGN (1ES 1101-232, 1ES 1218+304, and Mkn 501) simultaneous data were taken with the Suzaku X-ray satellite.
Fatty acid esters such as Lipiodol or Ethiodol are known to selectively localize in vascular hepatocellular carcinomas (HCC), following intraarterial hepatic administration. Lipiodol was labeled with radioactive /sup 131/I and administered in 47 patients with HCC for both imaging and therapy. The short term preliminary results suggest radiolabeled Lipiodol is effective in eliminating ascites, shrinking the tumor by a high internal radiation dose, and in improving symptomatology of these tumors. In the future, /sup 90/Y, which is a stronger pure beta-emitter (maximum beta energy of 2.27 MeV, a half life of 64 h, and a maximum penetration or beta range of 11mm), than /sup 131/I will be used for more effective treatment of HCC.
This report reviews Soviet R and D of (1) high-intensity negative ion sources and (2) transport and focusing of negative ion beams, using Soviet open literature of the past ten years, and correlates this data with data on Soviet institutes responsible for negative ion beam development. The Soviets are developing intense negative ion beams as the basis for creating neutral beams for injection into mirror traps and tokamaks, for inertial confinement fusion, and possibly for exoatmospheric beam weapon applications. The report focuses specifically on surface-plasma-type ion sources, which were first developed in the USSR and which show great promise for creating beams of high intensity, high brightness, and low emittance. Mechanisms for optimum negative ion beam transport are also discussed.
The Linac Coherent Light Source (LCLS) is a SASE x-ray Free-Electron Laser (FEL) based on the final kilometer of the Stanford Linear Accelerator. Such an FEL requires a high energy, high brightness electron beam to drive the FEL instability to saturation. When fed by an RF-photocathode gun, and modified to include two bunch compressor chicanes, the SLAC linac will provide such a high quality beam at 14 GeV and 1-{micro}m normalized emittance. In this paper, we report on recent linac studies, including beam stability and tolerances, longitudinal and transverse feedback systems, conventional and time-resolved diagnostics, and beam collimation systems. Construction and installation of the injector through first bunch compressor will be completed by December 2006, and electron commissioning is scheduled to begin in January of 2007.
A solar thermophotovoltaic (STPV) system has both terrestrial and space applications because thermal energy storage can be utilized. Excellent properties (heat of fusion=1800 j/gm and melting temperature=1680 K) make silicon the ideal thermal storage material for an STPV system. Using a one dimensional model with tapering of the silicon storage material, it was found that several hours of running time with modest lengths ({approximately}15 cm) of silicon are possible. Calculated steady-state efficiencies for an STPV system using an Er-YAG selective emitter and ideal photovoltaic (PV) cell model are in the range of 15{percent}{endash}17{percent}. Increasing the taper of the storage material improves both efficiency and power output. {copyright} {ital 1996 American Institute of Physics.}
Solid-state single-photon sources have many desirable features that make them attractive for applications in quantum information processing. However, the phase coherence of such devices can be severely compromised by coupling to the solid-state environment. Here, we study the effects of realistic dephasing environments on a pair of solid-state single photon sources in the context of quantum interference effects such as the Hong-Ou-Mandel dip. By means of exact solutions for the non-Markovian dynamics of the sources, we show that the resulting loss of visibility depends crucially on the timing of photon detection events. Our results demonstrate that the effective visibility can be improved via temporal post-selection, and also that time-resolved interference can be a useful probe of the interaction between the emitter and its host environment.
TRANSVERSE EMITTANCE PRESERVATION IS A MAJOR CONCERN OF THE LHC INJECTOR CHAIN. MINIMISATION OF THE BLOW-UP DUE TO MISMATCH AT INJECTION INTO THE SPS IS THEREFORE MANDATORY. WHILE THE TRANSVERSE POSITIONN OF THE BEAM IN THE SPS INJECTION LINE IS MONITORED BUNCH BY BUNCH BY AN OTR (OPTICAL TRANSITION RADIATION) SCREEN AND A FAST CCD (CHARGED COUPLED DEVICE) CAMERA, THE PHASE SPACE MATCHING AT INJECTION IS MONITORED BY AN OTR BASED MISMATCH MONITOR IN THE SPS RING. ORTHOGONAL TUNING KNOBS WERE DEVELOPED TO TUNE INDEPENDENTLY TWISS PARAMETERS, DISPERSION AND DISPERSION DERIVATIVE. IN THIS PAPER WE DESCRIBE THE MISMATCH CORRECTION MECHANISM AS WELL AS THE TWO MONITORING SYSTEMS. WE REPORT ON FIRST MEASUREMENTS WHICH WERE CARRIED OUT DURING THE 1998 SPS RUN.
At Los Alamos, we are building a free-electron laser (FEL) for industrial, medical, and research applications. This FEL, which will incorporate many of the new technologies developed over the last decade, will be compact in size, robust, and user-friendly. Electrons produced by a photocathode will be accelerated to 20 MeV by a high-brightness accelerator and transported using permanent-magnet quadrupoles and dipoles. They will form an electron beam with an excellent instantaneous beam quality of 10 {pi} mm mrad in transverse emittance and 0.3% in energy spread at a peak current up to 300 A. Including operation at higher harmonics, the laser wavelength extends form 3.7 {mu}m to 0.4 {mu}m. In this paper, we will describe the project and the programs to date. 10 refs., 10 figs., 1 tab.
Selenium 79 is a beta emitter produced from (235)U fission and is one of the long half-life radionuclides of interest in nuclear waste disposal problematic because of its potential migration capacity to the surface environment. Measurement of (79)Se is particularly difficult due to its low activity in waste matrices (about 10(-3)Bqg(-1)). A radiochemical procedure based on ion exchange separations was already described in a previous paper. This work presents different applications of the radiochemical separation to waste samples and an improvement of this procedure, including a selective extraction of selenium as diethylselenium in an organic solvent followed by a re-extraction in aqueous medium. This additional step allows the decontamination factor to be increased with the aim of counting (79)Se by liquid scintillation counting. PMID:19071740
A number of concrete culverts used to retrievably store drummed, dry, radioactive waste at the Savannah River Site (SRS), were suspected of containing ambiguous quantities of transuranic (TRU) nuclides. These culverts were assayed in place for Pu-239 content using thermal and fast neutron counting techniques. High resolution gamma-ray spectroscopy on 17 culverts, having neutron emission rates several times higher than expected, showed characteristic gamma-ray signatures of neutron emitters other than Pu-239 (e.g., Pu-238, Pu/Be, or Am/Be neutron sources). This study confirmed the Pu-239 content of the culverts with anomalous neutron rates and established limits on the Pu-239 mass in each of the 17 suspect culverts by in-field, non-intrusive gamma-ray measurements.
A number of concrete culverts used to retrievably store drummed, dry, radioactive waste at the Savannah River Site (SRS), were suspected of containing ambiguous quantities of transuranic (TRU) nuclides. These culverts were assayed in place for Pu-239 content using thermal and fast neutron counting techniques. High resolution gamma-ray spectroscopy on 17 culverts, having neutron emission rates several times higher than expected, showed characteristic gamma-ray signatures of neutron emitters other than Pu-239 (e.g., Pu-238, Pu/Be, or Am/Be neutron sources). This study confirmed the Pu-239 content of the culverts with anomalous neutron rates and established limits on the Pu-239 mass in each of the 17 suspect culverts by in-field, non-intrusive gamma-ray measurements.
The authors report experimental results on a high gradient 17 GHz RF photocathode gun. The photocathode RF gun is a novel electron beam source intended to meet the requirements set by future high-energy linear colliders and next generation free electron lasers. A coupled pair of pillbox TM{sub 010}-like resonators is excited by sidewall coupled microwaves at 17 GHz. A picosecond ultraviolet laser pulse illuminates one wall of the structure at the axis of symmetry. Electrons are released by the photoelectric effect and are accelerated by the electric field of the microwaves in the cavity. The high frequency of operation raises the RF breakdown limit allowing strong electric fields to be used. In turn, the intense fields result in rapid acceleration of the electrons to relativistic speeds and reduced space charge induced emittance growth.
Ferroelectric disks, coated with proper electrodes, can easily produce a dense plasma cloud when excited with a high-voltage pulse. This plasma can be a source of either electrons or ions depending on the sign of the extracting field set in front of the disk. We present the behavior of the disks operating at high frequency as emitters of both electrons and ions in two experimental configurations: (a) without and (b) with two screening grids. These two screening grids are inserted when the plasma must be confined within the cathode region. The system is capable of providing ion pulses of a few hundred milliamperes, whose length can range from a hundred nanoseconds to dozen microseconds. The electron pulses of energetic electrons have typically an amplitude higher than a couple of amperes. Tests at MHz repetition rate were positive as for stable operation.
To suit the needs of development for manufacture VLSI, we started to investigate liquid metal ion sources (LMIS) and focused ion beam (FIB) in 1984. Many kinds of emitters viz. neddle type, co-axial type and capillary type of Ga and Au LMIS and three kinds of eutectic alloys LMIS (Au-Si, Au-Si-Be, Pd-Ni-Si-Be-B) have been tested. A program which can calculate focused ion guns has been written. Four kinds of foused ion guns have been operated, a fine beam with diametic 0.1 #mu#m is obtained. Using the FIB a scanning ion microscope has been constructed. Some tests of etching and self-developing of nitrocellulose are described. (author).
The interaction of thermal radiation with conduction and convection in thermally developing absorbing, emitting, non-gray gas particulate turbulent suspension flow through a circular tube is investigated. The contribution of thermal radiation is obtained through evaluation of the total hemispherical emittance of the particulate cloud and through evaluation of single band absorptances for molecular gases, modified to account for the interaction with the particles. The governing differential equation is derived as a (nonlinear) energy equation, coupled with integral equations to find the thermal radiation contributions. The energy equation is solved numerically by an implicit finite difference with its iterative procedure. Qualitative results for Nusselt numbers are shown for a variety and range of parameters, such as optical thickness of particulates and single molecular gas bands, relative gas band position and band width, and temperature ratios (heated as well as ...
Investigations have been conducted to determine the feasibility of using collisional cooling for reducing the energy spreads and, consequently, the emittances of negative-ion beams. We have designed a gas-filled RF-quadrupole ion cooler equipped with provisions for retarding energetic negative ion beams to energies below thresholds for electron detachment at injection and for re-acceleration to high energies after the cooling process. The device has been used to cool O{sup -} and F{sup -} ion beams with initial energy spreads, {Delta}E > 10 eV to final energy spreads, {Delta}E {approx} 2 eV FWHM. Overall transmission efficiencies of {approx}14% for F{sup -} beams have been obtained. Experimental results show that electron detachment is the major loss mechanism for negative ions.
Investigations have been conducted to determine the feasibility of using collisional cooling for reducing the energy spreads and, consequently, the emittances of negative-ion beams. We have designed a gas-filled RF-quadrupole ion cooler equipped with provisions for retarding energetic negative ion beams to energies below thresholds for electron detachment at injection and for re-acceleration to high energies after the cooling process. The device has been used to cool O{sup -} and F{sup -} ion beams with initial energy spreads, {Delta}E > 10 eV to final energy spreads, {Delta}E {approx} 2 eV FWHM. Overall transmission efficiencies of {approx}14% for F{sup -} beams have been obtained. Experimental results show that electron detachment is the major loss mechanism for negative ions.
The WAND (Waste Assay for Nonradioactive Disposal) system can scan thought-to-be-clean, low-density waste (mostly paper and plastics) to determine whether the levels of any contaminant radioactivity are low enough to justify their disposal in normal public landfills or similar facilities. Such a screening would allow probably at least half of the large volume of low-density waste now buried at high cost in LANL`s Rad Waste Landfill (Area G at Technical Area 54) to be disposed of elsewhere at a much lower cost. The WAND System consists of a well-shielded bank of six 5-in.-diam. phoswich scintillation detectors; a mechanical conveyor system that carries a 12-in.-wide layer of either shredded material or packets of paper sheets beneath the bank of detectors; the electronics needed to process the outputs of the detectors; and a small computer to control the whole system and to perform the data analysis. WAND system minimum detectable activities (MDAs) for point sources range from ...
The Holifield Radioactive Ion Beam Facility now under construction at the Oak Ridge National Laboratory will use the 25 MV tandem accelerator for the acceleration of radioactive ion beams to energies appropriate for research in nuclear physics; negative ion beams are, therefore, required for injection into the tandem accelerator. Because charge exchange is an efficient means for converting initially positive ion beams to negative ion beams, both positive and negative ion sources are viable options for use at the facility. The choice of the type of ion source will depend on the overall efficiency for generating the radioactive species of interest. Although direct-extraction negative ion sources are clearly desirable, the ion formation efficiencies are often too low for practical consideration; for this situation, positive ion sources, in combination with charge exchange, are the logical choice. The high-temperature version of the CERN-ISOLDE positive ion source has been selected and a ...
The laser grooved buried grid (LGBG) cell was developed at the University of New South Wales, Australia. The enormous advantage of the Saturn technology is the simple formation of a selective emitter via two step diffusion, which is optimised on the surface for the charge carrier generation and under the metal grid for contact formation. The reflection losses due to shading are simultaneously minimised by the installation of the contacts at right angles in the wafer surface. Due to the increased infeed compensation, particularly the compensation covering the costs, the economic importance of the energy yield of a PV plant is growing. Ultimately, it is not just the installed output (KWp) that matters to the customer, but increasingly the specific yield (kWh/kWp). An increased energy yield with optimally matched components with the Saturn technology means high annual compensation, which in turn shortens the amortisation period. [Deutsch] Die LGBG-Zelle wurde an der ...
The effect of various window layers for InP solar cells are studied. Window materials that have type 1 and type 2 alignment in the window/emitter interface are compared. All window materials that form a type 2 alignment with InP, such as Al{sub 0.20}In{sub 0.80}P, Ga{sub 0.20}In{sub 0.80}P, Al{sub 0.55}In{sub 0.45}As and Al{sub 0.60}In{sub 0.40}P, cause a high interface recombination velocity, which deteriorates the carrier collection. This recombination takes place due to the spatially indirect quantum well transition between the triangular quantum wells formed in the interface. ZnSe as a window layer material with type 1 alignment does not have this problem, but still decreased response in the short wavelength region is observed due to misfit dislocation induced trap sites. Future prospects for the window layer development for InP are discussed. The discussion is extended also to other III-V semiconductor based solar cell materials, such as Ga{sub 0.5}In{sub ...
This topical review provides an overview of quantum dot micropillars and their application in cavity quantum electrodynamics (cQED) experiments. The development of quantum dot micropillars is motivated by the study of fundamental cQED effects in solid state and their exploitation in novel light sources. In general, light-matter interaction occurs when the dipole of an emitter couples to the ambient light field. The corresponding coupling strength is strongly enhanced in the framework of cQED when the emitter is located inside a low mode volume microcavity providing three-dimensional photon confinement on a length scale of the photon wavelength. In addition, coherent coupling between light and matter, which is essential for applications in quantum information processing, can be achieved when dissipative losses, predominantly due to photon leakage out of the cavity, are strongly reduced. In this paper, we will demonstrate that high-quality, low ...
We present a proof-of-concept analysis of the measurement of the health damage of ozone (O_3) produced from nitrogen oxides (NO_x=NO+NO_2) emitted by individual large point sources in the eastern United States. We use a regional atmospheric model of the eastern United States, the Comprehensive Air quality Model with Extensions (CAMx), to quantify the variable impact that a fixed quantity of NO_x emitted from individual sources can have on the downwind concentration of surface O_3, depending on temperature and local biogenic hydrocarbon emissions. We also examine the dependence of resulting O_3-related health damages on the size of the exposed population. The investigation is relevant to the increasingly widely used 'cap and trade' approach to NO_x regulation, which presumes that shifts of emission over time and space, holding the total fixed over the course of the summer O_3 season, will have minimal effect on the environmental outcome. By contrast, we show that a shift of a unit of ...
Free-electron laser (FEL) experiments have been conducted with the 38-MeV L-band electron linac at the Institute of Scientific and Industrial Research, Osaka University. It is a 1.3 GHz RF linac with a thermoionic gun, and equipped with two 12th and one 6th sub-harmonic prebunchers for producing the high-intensity single-bunch beam with a charge up to 67 nC/bunch. For oscillation experiments of FEL, the gun is replaced with that with a smaller cathode area in order to reduce the emittance of the beam. The normalized emittance has been measured to be 200 {pi} mm-mrad. The linac is operated in the long-pulse mode and one of the 12th sub-harmonic bunchers and the 6th sub-harmonic buncher are operated, so that the time duration of the macropulse is 4 {mu}s and the spacing between micropulses is 9.2 ns. The length of the micropulse is 30-40 ps and the charge in each micropulse is 2 nC. The electron beam from the linac is transported to a wiggler ...
Negative ions have attractive features as drivers for inertial confinement fusion, because they will avoid electron cloud effects, and could be efficiently photodetached to neutrals after the final focus, which could also be beneficial in heating warm dense matter targets. The halogens have large electron affinities, and thus should be able to produce high current densities of relatively robust negative ions. Recent experiments comparing chlorine beams to argon beams using the same source, extraction optics, and diagnostics have demonstrated that Cl"- beams can be produced with similar emittance to Ar"+ beams, and with about 34 the current density from the same configuration. The observed effective beam temperature of about 13eV, and the similarity of current densities show that negative halogen beams can meet the current density and emittance requirements of heavy ion fusion. The near equivalence of the Cl"- and Cl"++Cl_2"+ current densities ...
The importance of cellular dosimetry in both diagnostic and therapeutic nuclear medicine is becoming increasingly recognized. Experimental range-energy relations for electrons and alpha particles, along with derived geometric reduction factors, are used to calculate cellular absorbed fractions for these radiations. The resulting absorbed fractions are employed to calculate cellular S-values for several radionuclides. Cellular absorbed fractions for monoenergetic electron sources with energies ranging from 0.1 keV to 1 MeV, distributed uniformly in the source region, are calculated for several target {l_arrow} source combinations including cell{l_arrow}cell, cell{l_arrow}cell surface, nucleus{l_arrow}nucleus, nucleus {l_arrow}cytoplasm and nucleus {l_arrow}cell surface. Similar data are also provided for monoenergetic alpha particle sources with energies ranging from 3 to 10 MeV. S-values are also conveniently tabulated for {sup 32}P, {sup 35}S, {sup 86}Rb, {sup 89}Sr, {sup 90}Y, {sup ...
This report presents highlights of activities in the Acceleartor Technology (AT) Division from April through December 1978. The report is divided into 10 sections to cover work done by the four groups that make up AT Division (AT-1, AT-2, AT-3, and AT-4). Section I is a brief summary of the whole report. Sections II through VI describe work done by At-1, the Linac Technology Group. Subjects covered are the Pion Generation for Medical Irradiation Program, the Electronuclear Fuel-Producing Accelerator Program, the Gyrocon rf Amplifier Program, the Electron Linear Accelerator Program, and the Free Electron Laser Program. Section VII covers the Linear Accelerator Beam Dynamics development, and Sec. VIII deals with work with the H/sup -/ Ion Source. Most of the work in Secs. VII and VIII was done by AT-2, the Special Projects Group, although work on factors influencing emittance growth was done by MP-9, and results on emittance growth in the new ...
A high luminosity (10e34 - 10e35 cm square/s) electron-positron Collider (CLIC) with a nominal centre-of-mass energy of 3 TeV has been under study for a number of years at CERN within an international collaboration of laboratories and institutes to provide the HEP community with a new accelerator-based facility for the post-LHC era. In order to achieve the very high design luminosity, very low emittance beams have to be produced and focused down to very small beam sizes at the interaction point. Beam acceleration using high frequency normal-conducting structures operating at high accelerating fields significantly reduces the length and, in consequence, the cost of the linac. The overall length of the 3 TeV collider is about 33 km. The goals of the CLIC scheme are ambitious, and require further R&D to demonstrate that they are indeed technically feasible. A new test facility is being built at CERN for this purpose with the aim to demonstrate the key feasibility ...
This study is a task of ''Comprehensive study'' in ''nuclear energy basic technology research'', which is promoted under cooperation of four research institutes. The Electrotechnical Laboratory conducted, in 1991 in the first period of colaboration, on successful oscillation at visible region (598 nm) as the first case in Japan, construction of small type accumulation ring NIJI-IV for FEL, successful oscillation of visible range from 595 to 488 nm by installing optical krystron with maximum frequency in the world, and successful emittance lowering of accumulation beam by wide improvement of the ring. In the optical resonator, studies on minute loss measuring technique and on recovery from mirror deterioration were promoted. In the second period started from fiscal year of 1994, studies on FEL oscillation technique in short wavelength and upgrading of FEL corresponding to a frontier area were started, to succeed an oscillation experiment at 350 nm in ultraviolet ...
Field emitter devices are being developed for the gigatron, a high-efficiency, high frequency and high power microwave source. One approach being investigated is porous silicon, where a dense matrix of nanoscopic pores are galvanically etched into a silicon surface. In the present paper pore morphologies were used to characterize these materials. Using of Scanning Electron Microscope (SEM) and Transmission Electron Microscope (TEM) images of both N-type and P-type porous layers, it is found that pores propagate along the <100> crystallographic direction, perpendicular to the surface of (100) silicon. Distinct morphologies were observed systematically near the surface, in the main bulk and near the bottom of N-type (100) silicon lift-off samples. It is seen that the pores are not cylindrical but exhibit more or less approximately square cross sections. X-ray diffraction spectra and electron diffraction patterns verified that bulk porous silicon is still a ...
The objective of this contract is to design and build a small, lightweight, stand-alone thermophotovoltaic electric generator, capable of at least 100 Watts useful output for charging 24V batteries. The prototype generator built consists of a pre-mixed burner, a cylindrical selective emitter mantle surrounded by six silicon photovoltaic concentrator arrays. The arrays are cooled with forced-air heat exchangers using self-powered fans. The generator, operated at 117,00 W (40,000 BTU/hr) of fuel input rate, produces 122 W of electrical power at 1.0% of efficiency. The cooling and pre-mix fans consume 35 W of electrical power resulting in a net 85 Watts of electrical output for charging batteries. The generator`s output is capable of continuous charging five 12/24V batteries over 10 hours with a 9.07 Kg (20 lbs.) of propane gas.
We report on recent progress and improvements in the metal-organic chemical vapor deposition (MOCVD) growth of mid-infrared lasers and using a high speed rotating disk reactor (RDR). The devices contain AlAsSb active regions. These lasers have multi-stage, type I InAsSb/InAsP quantum well active regions. A semi-metal GaAsSb/InAs layer acts as an internal electron source for the multi-stage injection lasers and AlAsSb is an electron confinement layer. These structures are the first MOCVD multi-stage devices. Growth in an RDR was necessary to avoid the previously observed Al memory effects found in conventional horizontal reactors. A single stage, optically pumped laser yielded improved power (greater than 650 mW/facet) at 80K and 3.8um. A multi-stage 3.8-3.9um laser structure operated up to T=170K. At 80K, peak power greater than 100mW and a high slope- efficiency were observed in gain guided lasers.
The measurement of physiological parameters in man is possible with the help of positron emission tomography (PET) and radiopharmaceuticals labeled with short lived positron emitters as C 11, N 13, O 15 and F 18. With the use of this substances it is possible to make a tomographic map defining regional metabolic parameters in normal and diseased brain. This technique has therefore also be named 'in vivo autoradiography'. The possibility of applying C 11 or F 18 labeled deoxyglucose with PET for detecting regional and local changes in cerebral metabolic rate of glucose in brain development in children of 5 days to 1 year of age is discussed. Beyond this a relationship between cerebral metabolic rate of glucose, cerebral blood flow and cerebral metabolic rate of oxygen by use of this technique after inhalation of O 15 and C 11-labeled CO_2 is shown. Attention is drawn to the application of C 11-methyl-spiperone and PET to visualize dopamine receptor density in the ...
Concerning the gamma emitters, the only analysis on soils put in evidence the presence of cesium-137 ({sup 137}Cs), that does not come from the cyclotron functioning but from past man action as the Chernobylsk accident and the nuclear weapon tests in atmosphere. Independently of the functioning of the installation, we observe an increase of the ambient gamma radiation only near radioactive waste storage. It results of the storage of the former cyclotron elements. The induced increase is moderated because at 5 meters the values do not exceed the background noise. In relation with the functioning of the installation an increase of the ambient gamma radiation is noticed. Two causes are to considered: the release of radionuclides in atmosphere with gaseous effluents and the radiance of radiation sources inside the building. After the stopping of the installation (48 h at least), no increase of gamma radiation is observed. About the neutrons monitoring, the measures ...
RADIANT{trademark} is manufactured by United States Surgical Corporation, Vascular Therapies Division, (formerly Progressive Angioplasty Systems). The system comprises a liquid {beta}-radiation source, a shielded isolation/transfer device (ISAT), modified over-the-wire or rapid exchange delivery balloons, and accessory kits. The liquid {beta}-source is Rhenium-188 in the form of sodium perrhenate (NaReO{sub 4}), Rhenium-188 is primarily a {beta}-emitter with a physical half-life of 17.0 hours. The maximum energy of the {beta}-particles is 2.1 MeV. The source is produced daily in the nuclear pharmacy hot lab by eluting a Tungsten-188/Rhenium-188 generator manufactured by Oak Ridge National Laboratory (ORNL). Using anion exchange columns and Millipore filters the effluent is concentrated to approximately 100 mCi/ml, calibrated, and loaded into the (ISAT) which is subsequently transported to the cardiac catheterization laboratory. The delivery catheters are modified ...
The Versatile Toroidal Facility (VTF) is a large laboratory plasma machine of 1 meter major radius used to carry out investigations of ionospheric plasma turbulence. Spectral analysis has been performed on plasmas produced by the electron emitters. Interest has focused on the low frequencies below the lower hybrid resonance where ion acoustic and current-convective modes have been observed. Microwaves injected from a 3,000 watt magnetron produce dramatic changes to the low frequency spectrum. First, the parametric decay instability intensifies the ion acoustic modes in the region of plasma heated by the microwaves. Second, the normally dominant current-convective modes are greatly suppressed in the heated region due to the oscillating electric field of the pump wave. When the authors probe beyond the heated region, these two pump wave effects are no longer observed, presumably because the microwaves are denied access to beyond the heated region due to the high ...
A new foilless diode with a non-magnetically immersed cathode was recently designed and built for the Sandia Recirculating Linear Accelerator (RLA). Because there is also no radial component of electric field at the cathode, the electron beam starts almost parallel and is matched to a solenoidal transport system with minimum increase in divergence and radius. The electrode emission surface is specified by an area covered with felt which undergoes explosive electron emission at low electrical field stresses (60 kV/cm). The 1.7 MV, 4.8-kA produced beam is transported 1.5 meters to the injection region of the racetrack via a system of solenoids and focusing coils. The maximum transverse velocity component at injection point (1.5 m downstream from the cathode surface) is #beta# perpendicular = 0.03 and the radius r = 2.8 cm which give a quite small beam emittance #epsilon# = 0.08 rad-cm. Three- dimensional numerical simulations suggest that tangential injection into ...
A versatile, high brightness, volume type, low power RF source, capable of producing positive ion beams with intensities as high as 1 mA from gaseous feed materials and microamperes of negative ion beams has been characterized. The source can also be operated as a plasma sputter negative ion source to generate up to 1 mA of a selected species. The performance of the source in the positive and negative volume modes of operation can be greatly enhanced by addition of a removable, water cooled filament assembly in place of the negative sputter probe. For examine, the material utilization efficiencies of gaseous feed species can be more than doubled, total current intensities increased up to 40%, molecular dissociation fractions increased by 20% and minimum operating pressures reduced by a factor of four when operated in the volume mode. These added electrons also favorably effect, as a consequence of lower pressures, the emittance apparently through a reduction of ...
A Numerical study of beam dynamics was performed for two injector systems for the proposed National High Magnetic Field Laboratory at the Florida State University (FSU) Free Electron Laser (FEL) facility. The first considered a system consisting of a thermionic DC gun, two buncher cavities operated at 260 MHz and 1.3 GHz and two TESLA type cavities, and is very similar to the injector of the ELBE Radiation Source. The second system we studied uses a DC photogun (a copy of JLab FEL electron gun), one buncher cavity operated at 1.3 GHz and two TESLA type cavities. The study is based on PARMELA simulations and takes into account operational experience of both the JLab FEL and the Radiation Source ELBE. The simulations predict the second system will have a much smaller longitudinal emittance. For this reason the DC photo gun based injector is preferred for the proposed FSU FEL facility.
This work aims at improving the understanding of the dynamics of a Free Electron Laser (FEL) based on a storage ring. A new phenomenon of saturation by the electron bunch transverse dimensions is pointed out, during the FEL operation with a magnetic optics ''low emittance''. A part of this thesis work concerns the study of the longitudinal dynamics of the FEL depending on a parameter: the detuning between the pass frequency of the electrons and the back and return frequency of the laser pulse in the optical cavity. This study shows that the FEL presents a pulsed or a steady state behavior depending on the detuning. Besides, a spectro-temporal behavior of the FEL is pointed out showing the FEL pulse substructures and holes in the spectrum. Another part of this work concerns the response of the resonant FEL system, when a perturbation is applied on the gain. Under the effect of a modulation, the FEL can present a periodic or chaotic regime. The analysis of these ...
The Green-Chasman lattice, which is the basis for both NSLS storage rings, was conceived with insertion devices in mind. Long, field-free straight sections were provided in the design. The electron optics were chosen so that these sections had zero dispersion and the effects of new magnetic structures placed in these regions would have minimal effect on the emittance of the electron beam. This design concept has been followed by all high-brightness rings which were built subsequent to the NSLS. The X-Ray Ring straight sections also have a very small vertical {beta} function, in addition to the zero dispersion. This was done to optimize the brightness of wiggler sources. There is a further benefit however. The {beta} function determines the beam size and divergence at a particular point in the storage ring lattice. The size is proportional to {radical}{beta} and the divergence is proportional to 1/{radical}{beta}. Thus the electron beam is very small at the center ...
GaAs material and device structure optimization studies on optical-grade, millimeter-and-less grain-size polycrystalline Ge substrates are presented. We discuss the growth of high-quality epitaxial layers across various crystalline orientations of a polycrystalline substrate; this is important for obtaining high-performance solar cells. The GaAs solar cell on n-type poly-Ge substrate is a p-on-n type, with an undoped spacer between the p-emitter and the n-base. An experimental study of dark currents in these junctions, with and without the spacer, as a function of temperature (77K to 288K) is presented; this study suggests that the spacer reduces the tunneling contribution to dark current. In addition, we describe device-structure optimization studies that have led us to achieve an open-circuit voltage (V{sub oc}) exceeding 1 Volt and an AM1.5 efficiency of {approximately}19{percent} for a 4-cm{sup 2}-area GaAs cell on sub-mm grain-size poly-Ge. We have also ...
The alpha emitter plutonium-238 ("2"3"8Pu), which is produced in uranium-fueled, light-water reactors, is used as a thermoelectric power source for space applications. Inhalation of a mixed oxide form of Pu is the most likely mode of exposure of workers and the general public. Occupational exposures to "2"3"8PuO_2 have occurred in association with the fabrication of radioisotope thermoelectric generators. Organs and tissue at risk for deterministic and stochastic effects of "2"3"8Pu-alpha irradiation include the lung, liver, skeleton, and lymphatic tissue. Little has been reported about the effects of inhaled "2"3"8PuO_2 on peripheral blood cell counts in humans. The purpose of this study was to investigate hematological responses after a single inhalation exposure of Beagle dogs to alpha-emitting "2"3"8PuO_2 particles and to extrapolate results to humans.
We present new low resolution Spitzer mid-infrared spectroscopy of a sample of 20 ROSAT selected local Narrow Line Seyfert 1 galaxies (NLS1s). We detect strong AGN continuum in all and clear PAH emission in 70% of the sources. The 6.2 micron PAH luminosity spans three orders of magnitudes, from ~10^(39) erg/s to ~10^(42) erg/s providing strong evidence for intense ongoing star formation in the circumnuclear regions of these sources. Using the IRS/Spitzer archive we gather a large number of additional NLS1s and their broad line counterparts (BLS1s) and constructed NLS1 and BLS1 sub-samples to compare them in various ways. The comparison shows a clear separation according to FWHM(H_beta) such that objects with narrower broad H_beta lines are the strongest PAH emitters. We test this division in various ways trying to remove biases due to luminosity and aperture size. Specifically, we find that star formation activity around NLS1 AGN is larger than around BLS1 of the ...
The design of a small injection linac for a compact medical synchrotron is discussed. The linac design is based on interdigital H-type (IH) drift-tube structure with alternative phase focusing (APhF). A high acceleration rate and an absence of magnetic lenses inside drift-tubes reduce the cost and length of APhF-IH linac in comparison with HIMAC linac based on Alvarez structure with magnet quadrupoles inside drift-tubes. To reduce effects of emittance growth, the RFQ structure is used in front of the APhF linac. In such linac layout, the current transmission of a carbon beam can reach up to 90-100%. In this report, the basic parameters of whole linac are presented, while the design of APhF structure is considered in details. Two reference designs of 4 MeV/u 200 MHz APhF linacs with different voltage distributions along the whole tank have been generated and analyzed numerically. For the first design, a constant voltage distribution along the tank is assumed. The ...
Recently, a drive laser for an S-band (2.86 GHz) rf photoinjector, designed to provide a pulse that has a flat temporal and spatial profile, has been built, commissioned, and put into service as part of the LLNL Compton-scattering monoenergetic {gamma}-ray source program. This laser is based on an all-fiber oscillator and front-end amplification system, and provides both the laser light to generate the electrons as well as the rf signal that is amplified to accelerate them. Now, a new 11.424 GHz photoinjector is being developed, which has required a revised design for the laser system. The higher frequency has placed more stringent requirements on the synchronization stability, delivered pulse length, and pulse rise times to maintain the desired emittance. Presented here are the overall design and measured performance of the current system and a discussion of what changes are being made to address observed shortcomings and more demanding requirements to make the ...
In the present investigation the performance of digital data acquisition (DA) and analogue data acquisition (AA) systems are compared in neutron-induced fission experiments. The DA results are practically identical to the AA results in terms of angular-, energy- and mass-resolution, and both compare very well with literature data. However, major advantages were found with the digital techniques. DA allows for a very efficient #alpha#-particle pile-up correction. This is important when considering the accurate measurement of fission-fragment characteristics of highly #alpha#-active actinide isotopes relevant for the safe operation of Generation IV reactors and the successful reduction of long-lived radioactive nuclear waste. In case of a strong #alpha#-emitter, when applying the #alpha#-particle pile-up correction, the peak-to-valley ratio of the energy distribution was significantly improved. In addition, DA offers a very flexible expanded off-line analysis and ...
Studies have been conducted to determine the feasibility of using collisional cooling for reducing emittances and energy spreads in negative-ion beams to levels commensurate with effective isobaric purification with conventional high-resolution electromagnetic isobar separators as required for use at the Holifield Radioactive Ion Beam Facility (HRIBF). We have designed a gas-filled radio frequency quadrupole ion cooler equipped with provisions for retarding energetic negative-ion beams to energies below thresholds for electron detachment at injection and for re-acceleration to initial energies after the cooling process. The device has been used to cool several ion beams with initial energy spreads, {delta}E>10 eV to final energy spreads, {delta}E{approx}2 eV FWHM, including O{sup -} and F{sup -}. Overall transmission efficiencies of {approx}14% for F{sup -} beams have been obtained. Experimental results show that electron detachment is the major loss ...
The results from a hot test, using authentic HLLW solution, of the CTH actinide separation process are reported. The process consists of three solvent extraction cycles for separation of actinides and technetium from reprocessing high level liquid waste, utilizing HDEHP, TBP, and HDEHP in sequence, and an optional step for sorption on inorganic ion exchangers of the fission product content in the process raffinate. In general the process worked according to predictions but a malfunctioning feed pump gave a 10% loss of Pu to one stream. The hot test indicating that U and Pu can be recovered with losses below 0.1% and Am, Cm with a loss below 0.2%. Np and Tc were difficult to follow because of the low activity of /sup 237/Np and because /sup 99/Tc is a pure beta emitter, but the results indicate that also these elements behaved according to predictions, i.e., that recoveries >= 99.8% for Np and >= 97% for Tc can be achieved. For the HLLW stream the solvent ...
The spectral properties of Lyman break galaxies (LBGs) offer a means to isolate pure samples displaying either dominant Ly-alpha in absorption or Ly-alpha in emission using broadband information alone. We present criteria developed using a large z ~ 3 LBG spectroscopic sample from the literature that enables large numbers of each spectral type to be gathered in photometric data, providing good statistics for multiple applications. In addition, we find that the truncated faint, blue-end tail of z ~ 3 LBG population overlaps and leads directly into an expected Ly-alpha emitter (LAE) population. As a result, we present simple criteria to cleanly select large numbers of z ~ 3 LAEs in deep broadband surveys. We present the spectroscopic results of 32 r' <~ 25.5 LBGs and r' <~ 27.0 LAEs at z ~ 3 pre-selected in the Canada-France-Hawaii Telescope Legacy Survey that confirm these criteria.
Safety standards for exposure to radiofrequency radiation must be based upon biologic consequences of exposure to such environments. Behavioral-based measures are considered to be the most-sensitive indices of biological effects. Current safety guidelines are based upon average power density and may not be relevant to the high-peak-power, short pulse width microwave radiation produced by newly developed high peak power microwave sources. The effects of exposure to high-peak-power radiation on reflexive responding and motor function in Fischer 344/N rats were assessed by measuring startle and general activity, and disruption of on-going performance of a rotarod task, respectively. The emitter used was the TEMPO repeat pulse axially extracted vircator. Exposure to single pulses resulted in significant startle responses. Exposure to 1 pps for 10 s produced significant alterations in baseline activity and marked disruption of performance of the rotarod task. The ...
A combined PVD/PECVD process for the vacuum deposition of titanium containing amorphous hydrogenated carbon films is described. Elemental compositions of the deposited films have been determined by in situ core level photoelectron spectroscopy (XPS). The long-term stability of the plasma process has been demonstrated. Target poisoning has not been observed. We have fabricated optical selective surfaces by the deposition of a-C:H/Ti multilayers onto aluminum substrates. Even though we have not optimized layer thicknesses and stoichiometries so far, the experimental results are promising: solar absorptance {alpha}{sub S} of 0.876 and thermal emittance {epsilon}{sub 100C} of 0.061 have been achieved yielding an optical selectivity sis defined as{alpha}{sub S}/{epsilon}{sub 100C} of 14.4. Accelerated aging tests of these coatings have demonstrated their aging stability: the service lifetime is predicted to amount to more than 25 years. Raman spectroscopy has been used ...
An aerial radiological survey was conducted over the Department of Energy's Hanford Site near Richland, Washington, during the period 5 July through 26 August 1988. The survey was expanded, and additional flights were conducted to the east of the site and along the banks of the Columbia River down to McNary Dam near Umatilla. The survey was flown at altitude of 61 meters (200 feet) by a helicopter containing 17 liters (eight 2 in. x 4 in. x 16 in.) of sodium iodide detectors. Gamma ray data were collected over the survey area by flying north-south lines spaced 122 meters (400 feet) apart. The processed data indicated that detected radioisotopes and their associated gamma ray exposure rates were generally consistent with those expected from normal background emitters and man-made fission/activation products resulting from activities at the site. External exposure rates were generally 10 microroentgens per hour (#mu#R/h) with some operating areas over 1000 #mu#R/h. ...
An aerial radiological survey was performed from 11 to 20 March 1982 over a 260-square-kilometer area centered on the Grand Gulf Nuclear Station at Port Gibson, Mississippi (the station was not yet in operation at the time of the survey). All gamma ray data were collected by flying east-west lines spaced 152 meters apart at an altitude 91 meters above ground level. Processed data showed that all gamma rays detected within the survey area were those expected from naturally occurring terrestrial background emitters. Count rates obtained from the aerial platform were converted to exposure rates at 1 meter above the ground and are presented in the form of an isoradiation contour map. The observed exposure rates were between 5 and 13 microroentgens per hour (#mu#R/h), with most of the area ranging from 9 to 10 #mu#R/h. These values include an estimated cosmic ray contribution of 3.6 #mu#R/h. The exposure rate obtained from soil samples and ionization chamber ...
A multicusp magnetic field plasma surface ion source, normally used for H/sup /minus//ion beam formation, has been modified for the generation of high-intensity, pulsed, heavy negative ion beams suitable for a variety of uses. To date, the source has been utilized to produce mA intensity pulsed beams of more than 24 species. A brief description of the source, and basic pulsed-mode operational data, (e.g., intensity versus cesium oven temperature, sputter probe voltage, and discharge pressure), are given. In addition, illustrative examples of intensity versus time and the mass distributions of ion beams extracted from a number of samples along with emittance data, are also presented. Preliminary results obtained during dc operation of the source under low discharge power conditions suggest that sources of this type may also be used to produce high-intensity (mA) dc beams. The results of these investigations are given, as well, and the technical issues that must be ...
Objective: To estimate exposure dose of personnel around patients by Monte Carlo method and integration method. Methods: Exposures were estimated by a Monte Carlo practical program with Visual Basic 6.0 and integration method using 'pen-and-paper'. Results: Exposures for rectangle and ellipse sources were calculated. The difference between different methods for various sources were 0.88% and 0.61%, respectively. Conclusion: The results estimated by Monte Carlo method are close to those of integration method. It is illustrated that doses of other people estimated by Monte Carlo method are significant
The three determination methods of alpha activity ration are described, namely geometric progression method, extrapolation method and curve fitting method. The validity of the geometric progression method is demonstrated in the present work. The "2"3"8Pu/("2"3"9Pu + "2"4"0Pu) evaluated by extrapolation method is compared with that by geometric progression method. Also, the "2"3"8Pu/("2"3"9Pu + "2"4"0Pu)evaluated by curve fitting method is compared with that by geometric progression.
In an epidemiological study of the somatic late effects risk following incorporation of a short lived {alpha}-emitter, 1473 ankylosing spondylitis patients treated with repeated intravenous injections of {sup 224}Ra in the years 1948 - 75, have been observed in the GSF. The usual therapeutic plan consisted of a total of 10 - 12 injections of 1.036 MBq (28 {mu}Ci) of {sup 224}Ra each, given at weekly intervals; this would result in an cumulative {alpha}-dose of 0.56 - 0.67 Gy to the marrow-free skeleton of a 70-kg-man (standard man). These patients have been followed together with a control group of ankylosing spondylitis patients not treated with radioactive drugs and/or X-rays. Until May 1993 (mean follow-up time 19.9 yr), 595 patients of the exposure group and 722 patients of the control group have died, causes of death have been ascertained for 578, resp. 668 patients. Among others we observed in the exposure group 10 cases of leukaemia (vs. 2.7 - 2.8 cases ...
The general methods used to complete measurements of human exposures are identified and illustrations are provided for the cases of indirect and direct methods used for exposure analysis. The application...Full Text Available
X-ray diffraction enhanced imaging (DEI) is one of X-ray phase-contrast imaging methods, which is applied to inspect internal structures of weakly absorbing low-Z samples. The key problem of the DEI is how to extract phase information which is expressed by refraction-angle images from a series of DEI images measured in different positions of the rocking curve of the analyzer. Three effective extraction methods are presented in this paper: the statistical geometric-optics-approximation method, the maximum refraction-angle method and the Gaussian curve fitting method. They are compared with the existing methods, such as the D. Chapman's geometric optics approximation method and the multiple-images statistical method. A 2D computer simulation experiment is performed to draw comparisons of these ...
X-ray diffraction enhanced imaging (DEI) is one of X-ray phase-contrast imaging methods, which is applied to inspect internal structures of weakly absorbing low-Z samples. The key problem of the DEI is how to extract phase information which is expressed by refraction-angle images from a series of DEI images measured in different positions of the rocking curve of the analyzer. Three effective extraction methods are presented in this paper: the statistical geometric-optics-approximation method, the maximum refraction-angle method and the Gaussian curve fitting method. They are compared with the existing methods, such as the D. Chapman's geometric optics approximation method and the multiple-images statistical method. A 2D computer simulation experiment is performed to draw comparisons of these methods. ...
The paper describes advances in statistical methods for prevention research with a particular focus on substance abuse prevention. Standard analysis methods are extended to the typical research...Full Text Available
The paper present the results of the study on D.U. (depleted uranium) contamination in the environment and possible effects on animal healths in the region o f Bujanovac. Samples of soil, feed, leaves, grass, lichen, moss, honey and water were collected randomly in 2003/2004 in the vicinity of the target area (500-1000 m) and 5 km from the target area. Activity of the radionuclides ({sup 226}Ra, {sup 232}Th, {sup 40}K, {sup 210}Pb, {sup 238}U, {sup 235}U, {sup 137}Cs, {sup 7}Be) in soils, grass, lichen, moss and honey was determined on Hp Ge detector (Canberra, relative efficiency 23%) by standard gamma spectrometry. Total alpha and beta activity in water was determined on proportional alpha/beta counter (Canberra 2400, efficiency for alpha emitters 11%, efficiency for beta emitters 30%). Non significantly higher values of concentrations of {sup 226}Ra, {sup 232}Th, {sup 238}U and {sup 235}U were measured in the immediate vicinity of the ...
Optimization methods are applied to complex problems power systems, economics, and geodesy. Transformation methods and conjugated gradient methods are used to solve the constrained problems in power systems and economics. Conjugated gradient methods are used to solve the unconstrained geodesy problem. Broad applications of the transformation methods are emphasized. In the geodesy problem, the computational efficiency of the Fletcher-Reeves method for optimization of quadratic functions is emphasized. In this problem special storage schemes were used. The method of solution of the economics problem is compared with Beale's method.
This invention relates to new phosphor materials and to combinatorial methods of synthesizing and detecting the same. In addition, methods of using phosphors to generate luminescence are also disclosed.
Except nuclear industry, diverse structures (hospitals, of research or manufacturers) can have appeal to the use of radioisotopes conditioned under unsealed shape. Such practices lead to tolerate releases in environment in the respect of a statutory device. So the collective network can contain radioisotopes the future of which is going to depend partially on the cleaning applied to waste water. This study through the analysis of a concrete case, has for objective to inform about the future of gamma radioelements present in waste water treated by a wastewater treatment plant. The contamination of the network is essentially due to Tc{sup 99} and I{sup 131}, radioelements present whatever the working day and the hour considered. The total estimated in-load for a day is important, of the order of 4000 MBq for Tc{sup 99} and 15 to 300 MBq for I{sup 131}. The assessment of cleaning of the station shows that this one plays a role towards this pollution through these stages of treatment. ...
Full text: The general population is daily exposed to chronic, low doses of ionizing radiation (IR) from both natural and artificial sources. The biological consequences of acute, high dose IR exposure can be readily determined; however, the nature and significance of low dose, low dose-rate IR effects are still the subject of debate. Confounding the issue, are the phenomena collectively referred to as the Radiation-induced Bystander Effect (RIBE). The RIBE describes a collection of in vitro observations that suggest the presence of a soluble, transmissible factor(s) released from irradiated cells that can induce a biological response in un-irradiated cells. The induction, nature and magnitude of the RIBE varies between cell culture systems, radiation sources and end-points measured. Efforts to confirm the presence of the RIBE in vivo have been confined to in vivo-like culture systems and limited work with tumour and bone-marrow transplantation models. Validation of the RIBE in vivo ...
{sup 188}Re is a {beta}{sup -} (Emax=2.12 MeV) and {gamma} (155 keV) emitter. Since its chemistry is similar to that of the largely employed tracer, {sup 99m}Tc, molecules of hyaluronic acid (HA) have been labelled with {sup 188}Re to produce a target specific radiopharmaceutical. The radiolabeled compound, i.v. injected in healthy mice, is able to accumulate into the liver after a few minutes. To study the effect of metabolic radiotherapy in mice, we have built a small gamma camera based on a matrix of YAP:Ce crystals, with 0.6x0.6x10 mm{sup 3} pixels, read out by a R2486 Hamamatsu PSPMT. A high-sensitivity 20 mm thick lead parallel-hole collimator, with hole diameter 1.5 mm and septa of 0.18 mm, is placed in front of the YAP matrix. Preliminary results obtained with various phantoms containing a solution of {sup 188}Re and with C57 black mice injected with the {sup 188}Re-HA solution are presented. To increase the space resolution and to obtain two orthogonal ...
We investigate the sky distribution of z ~ 6 Lyman break galaxies selected as i'-dropouts having i' - z' > 1.45 down to z' < 26.5 in the Subaru Deep Field (SDF). We discover 37 i'-dropouts clustered in a projected comoving 21.6 x 21.6 Mpc^2 region at z = 6, showing a local density excess. Carrying out follow-up spectroscopy, we identify four of them as Lyman-alpha emitters at z = 5.92, 6.01, 6.03 and 6.03 (spread over a distance of 46.6 Mpc). The number density of the cluster itself in SDF is ~ 2.2 x 10^{-7} Mpc^{-3}, smaller than those of protoclusters (i.e., forming galaxy clusters) at z ~ 2-5.7. Also, the structure shows ~4-21 times larger galaxy number density than those of z ~ 6 galaxies in a general field. It has a mass of M ~ 1.5^{+1.8}_{-0.5} x 10^{15}M_sun, comparable to those of z ~ 0-5 protoclusters. Since the contamination of our sample by interlopers is estimated to be quite low, 5.9%, most of the other unconfirmed i'-dropouts in the overdense ...
A study has been made of the reaction [sup 86]Kr + [sup 63]Cu at incident energies of 486, 550, 640, and 730 MeV. Measurements include cross sections, angular distributions, and energy spectra for light charged particles ([sup 1,2,3]H and [sup 4]He), intermediate mass fragments (IMF) (4 [le] Z [le] 17), and heavy fragments (Z [ge] 18). Coincidences between light charged particles and between particles and fragments have been measured to obtain cross sections, energy spectra, and angular distributions. Statistical model analysis of the energy spectra for [sup 1]H and [sup 4]He detected in coincidence with the fragments has allowed estimation of [sup 1]H and [sup 4]He multiplicities associated with the evaporation residues, fragments, and composite nuclei prior to scission. A comparison of cross sections, energy spectra, angular distributions, and particle multiplicities for these matched entrance channels has provided the means for a detailed test of the Bohr Independence Hypothesis. ...
Positron Emission Tomography (PET) was used to analyze in vivo antagonist binding to human myocardial muscarinic cholinergic receptor. The methiodide salt of the muscarinic antagonist, quinuclidinyl benzilate (MQNB), was labeled with the positron emitter, Carbon-11, and injected intravenously to 8 normal subjects. /sup 11/C-MQNB concentration was determined in vivo in the ventricular septum from 40 cross-sectional images acquired at the same transverse level over a period of 70 minutes. In 4 subjects, various amounts of unlabeled atropine were rapidly injected at 20 minutes to study whether atropine competitively inhibited MQNB. The kinetics of binding of /sup 11/C-MQNB were not the same in vivo and in vitro. The apparent dissociation rate of /sup 11/C-MQNB in vivo was much slower (by 1 to 2 orders of magnitude) than that observed in vitro with /sup 3/H-QNB. After atropine injection, /sup 11/C-MQNB dissociated from its binding sites at a rate that apparently ...
A high power (200KV), intense current density, low emittance (71mmmrad), high brightness (8x10{sup 10}A/m rad) electron beam was generated in the 10cm long, high-voltage-resistive multi-gap hollow cathode pseudospark chamber filled with 15pa nitrogen and driven by an improved pulse line accelerator. The beam was ejected with the 1mm diameter, the 2.2KA beam current, and the 400ns pulse length, and could propagated 20cm in the drift tube. At a distance of 5cm from the anode it penetrated consecutively an acid-sensitive discoloring film and a 0.05mm-thick copper foil both stuck closely, left 0.6mm and 0.3mm holes on them, respectively. That 10 shots on an acid-sensitive film produced a hole of 1.6mm at 7cm downstream of anode showed its good repeatability. After 60 shots the pseudospark discharge chamber was disassembled and observed that almost no destructive damage traces left on the surfaces of its various electrodes and insulators. But on almost all the surfaces ...
The use of the focused ion beam (FIB) systems has increased to a high level in recent years. The imaging, milling, and deposition capabilities of the FIB make it the ideal instrument for e.g., site-specific failure analysis, specimen preparation and nano-machining. Ion channelling contrast allows for selective imaging of polycrystalline and polyphase microstructures. In addition, the FIB and CrossBeam registered instruments are unique stand-alone analytical tools. Their vast capabilities have enabled numerous applications into the semiconductor and materials sciences applications. These integrated CrossBeam registered Tools enable the observation and direct control of the FIB operation in real time. In addition to the improved accuracy and resolution the electron beam adds analytical capabilities as STEM, EDS and EBSP to the instruments. To ensure a safe and reliable operation of the instrument, a dedicated vacuum system is needed. This type of instrument combines a high resolution ...
Several short-lived, high-energy beta emitters are being proposed as the radionuclide components for molecular-targeted potential cancer therapeutic agents. The laboratory mice used to determine the efficacy of these new agents have organs that are relatively small compared to the ranges of these high-energy particles. The dosimetry model developed by Hui et al. was extended to provide realistic beta-dose estimates for organs in mice that received therapeutic radiopharmaceuticals containing 90Y, 188Re, 166Ho, 149Pm, 64Cu, and 177 Lu. Major organs in this model included the liver, spleen, kidneys, lungs, heart, stomach, small and large bowel, thyroid, pancreas, bone, marrow, carcass, and a 0.025-g tumor. The study as reported in this paper verifies their results for 90Y and extends them by using their organ geometry factors combined with newly calculated organ self-absorbed fractions from PEREGRINE and MCNP. PEREGRINE and MCNP agree to within 8% for the worst-case ...
A microwave hydrogen ion source was developed to improve reliability, and to increase operation time of proton linac application systems. The ion source needs no filament in the discharge chamber, which leads to better reliability and less maintenance time. The developed source produced a maximum hydrogen ion beam current of 70 mA (high current density of 360 mA/cm2, beam energy of 30 keV) with a 5 mm diam extraction aperture and 1.2 kW microwave power. The proton fraction was increased with an increase in rf power and reached around 90% at 1 kW. Measured 90% beam normalized emittance was 0.4 #pi# mm mrad. Rise times of rf power and beam current to 90% of the final values were about 30 and 35 #mu#s, respectively, at a pulse operation mode with 400 #mu#s pulse width and 100 Hz repetition rate. The dynamic range of beam currents was enlarged (3-63 mA) in the pulse mode with a modified rf wave form to assist ignition of microwave discharge. These performance ...
During the previous 9 months the major part of the Fusion-FEM has been constructed. The 2 MV Insulated Core Transformer, the electron gun, the accelerator, the focusing lenses and the undulator have been tested on-site. In the present - temporary - set-up, the electron beam line consists of a 12 A, 80 keV thermionic electron gun, a 2 MeV dc accelerator, beam transport optics, the undulator and a collector. The gun is mounted in the high voltage terminal, which is now at -2 MV, and the undulator and mm-wave system am at ground potential outside the SF{sub 6}-filled pressure tank. This so-called inverse set-up allows easy access to the larger part of the beam line, the undulator and the mm-wave system, which is important in the conditioning phase. The decelerator and depressed collector am not yet installed. The design of the electron beam line has been optimised using the GPS particle-tracking code and the TOSCA code. The TOSCA code is used for accurate field calculations of the ...
Investigations of radionuclide metabolism and effects in various mammalian species revealed important similarities between animals and humans and between some animal species. These include skeletal deposition of radium and radiostrontium in bone volume; deposition on bone surfaces of plutonium and other actinides; liver deposition of actinides; induction of skeletal or liver malignancies by these radionuclides; induction of tooth and jaw abnormalities; mammary cancer induction by radium in humans and in the beagle; depression of circulating cells in blood; and induction of bone fractures. There are also inter-species differences that may not have been noted if multiple species (including humans) had not been studied. Some of these are more rapid excretion of radium in humans compared with most other mammals; induction by radium of eye melanomas in animals but not humans; rapid loss of deposited plutonium from liver in many species of mice and rats but not in humans and dog; substantial ...
The energy flux distribution at the aperture of cavity receivers is an important parameter that characterizes the performance of point-focusing solar concentrators. Together with simplifying assumptions about cavity absorptance, emittance, and convective losses, good estimates of the dish-receiver collection efficiency as a function of incident flux and effective cavity temperature can be obtained. For detailed design of cavity receivers, however, it is necessary to determine the incident flux distribution on the interior surfaces. This information is needed ultimately to determine the resulting energy fluxes to the working fluid, temperature distributions within the cavity, and receiver performance. Knowing the incident flux distributions provides the designer with insights such as where hot-spots are likely to occur, where heat exchange surfaces are needed, and where more detailed analysis might be warranted. Solar receivers are heat exchangers and incident flux ...
A next generation e"+-e"- linear collider in the TeV range can be converted into a #gamma#-#gamma# collider by converting it to e"--e"- operation and then generating #gamma#-rays via Compton backscattering with optical beams. This provides unique access to some areas of fundamental physics as well as highly desirable redundancy to the collisions. The required optical beam (with a wavelength of about 1 micron) must have very high peak power, (about 1 TW) as well as average power (about 10 kW). To achieve a 1 : 1 conversion from an electron to #gamma#-quantum, each micropulse must contain about one Joule and must be about one picosecond long, the micropulse peak power being about one Terawatt. To match the electron beam pulse structure, a macropulse consists of a sequence of about one hundred micropulses separated by about one nanosecond, and the macropulses am repeated at a rate of about 100 Hz. Thus, the time average power is about 10 kW propose and analyze a promising scheme to ...
The work of this association is cut according to 6 axes. Three publications: radiological quality of marine and continental waters of the Normandy coast (synthesis 1997 and 1998); preliminary study of the iodine 129 distribution in the environment of the reprocessing plant of La Hague with terrestrial moss (Homalotecium sericeum); radiological surveillance of the aquatic environment of the nuclear facilities on the area of La Hague (1997 and 1998). The second axis concerns the radiation protection with a campaign of radon measures in a school of the Vire rural district (june 1999). The third part is devoted to the radioecology with the surveillance of radioactivity in the aquatic continental environment of nuclear facilities and the radioecological surveillance (1999) of the building site of Cogema la Hague in the area of tidal range of the Moulinets cove. The fourth part concerns the radioactive waste and environment, with the study of the distribution of the artificial gamma ...
During the last decade, new radiopharmaceutical have been introduced for brain imaging. The marked differences of these tracers in tissue specificity within the brain and their increasing use for diagnostic studies support the need for a more anthropomorphic model of the human brain and head. Brain and head models developed in the past have been only simplistic representations of this anatomic region. For example, the brain within the phantom of MIRD Pamphlet No. 5 Revised is modeled simply as a single ellipsoid of tissue With no differentiation of its internal structures. To address this need, the MIRD Committee established a Task Group in 1992 to construct a more detailed brain model to include the cerebral cortex, the white matter, the cerebellum, the thalamus, the caudate nucleus, the lentiform nucleus, the cerebral spinal fluid, the lateral ventricles, and the third ventricle. This brain model has been included within a slightly modified version of the head model developed by ...
During the last decade, new radiopharmaceutical have been introduced for brain imaging. The marked differences of these tracers in tissue specificity within the brain and their increasing use for diagnostic studies support the need for a more anthropomorphic model of the human brain and head. Brain and head models developed in the past have been only simplistic representations of this anatomic region. For example, the brain within the phantom of MIRD Pamphlet No. 5 Revised is modeled simply as a single ellipsoid of tissue With no differentiation of its internal structures. To address this need, the MIRD Committee established a Task Group in 1992 to construct a more detailed brain model to include the cerebral cortex, the white matter, the cerebellum, the thalamus, the caudate nucleus, the lentiform nucleus, the cerebral spinal fluid, the lateral ventricles, and the third ventricle. This brain model has been included within a slightly modified version of the head model developed by ...
The results of experiments with a short period (9.6 mm) wiggler sheet electron beam (1.0 mm x 2.0 cm) millimeter-wave free electron laser (FEL) amplifier are presented. This FEL amplifier utilized a strong wiggler field for sheet beam confinement in the narrow beam dimension and an offset-pole side-focusing technique for the wide dimension beam confinement. The beam analysis herein includes finite emittance and space-charge effects. High-current beam propagation was achieved as a result of extensive analytical studies and experimental optimization. A design optimization resulted in a low sensitivity to structure errors and beam velocity spread, as well as a low required beam energy. A maximum gain of 24 dB was achieved with a 1-kW injected signal power at 86 GHz, a 450-kV beam voltage, 17-A beam current, 3.8-kG wiggler magnetic field, and a 74-period wiggler length. The maximum gain with a one-watt injected millimeter-wave power was observed to be over 30 dB. The ...
In this paper, we have designed power system stabilizer (PSS) using object-oriented method. There are several types of power system stabilizer, A proportional-integral (PI) controller is very simple for practical implementation. Therefore it has been widely employed by the industry. The methods of obtaining the gains (Ki,Kp) of PI controller are root-locus method and sub-optimal regulator approach. But these methods are cannot be applicable to nonlinear system and faulted power system. So we proposed a new method which can be applied to nonlinear system by numerical analysis method. The method of dynamic system simulation by numerical method is very difficult and complex. We proposed flexible simulation method for complex power system analysis using object-oriented programming (OOP) and applied to PI ...
The defects localization in power cables follows several steps: identification, pre-localization and precise localization. Pre-localization methods, other than echo-metry, are presented first: bridge methods, particular case of low voltage networks, future perspectives. Then, the precise localization methods are described: magneto-acoustic method, audible frequencies method. The particular case of underwater and high-voltage cables is considered too (oil and gas leaks detection). (J.S.)
By the linear augmented plane wave method (APW) the energy zone of silver and technetium structure is calculated. The potential has been determined by means of superposition of atomic charge densities according to slater exchange method. Total and partial state densities have been calculated by the tetrahedron method. The APW-method convergence on the example of silver is studied, the comparison with the calculation results by the APW method and other data is carried out. The APW method high efficiency is pointed out. In dipole approximation the intensity distribution in L"3, M"5 N"3 technetium emission spectra is calculated.
The Kernel Polynomial Method (KPM) has been successfully applied to tight-binding electronic structure calculations as an O(N) method. Here the authors extend this method to nonorthogonal basis sets with a sparse overlap matrix S and a sparse Hamiltonian H. Since the KPM method utilizes matrix vector multiplications it is necessary to apply S{sup {minus}1}H onto a vector. The multiplication of S{sup {minus}1} is performed using a preconditioned conjugate gradient method and does not involve the explicit inversion of S. Hence the method scales the same way as the original KPM method, i.e. O(N), although there is an overhead due to the additional conjugate gradient part. The authors show an application of this method to defects in a titanate/platinum interface and to a large scale electronic structure calculation of ...
A method for ranking interval objects is proposed and analyzed; the characteristics of those objects are represented by pessimistic, optimistic, and most probable estimates. The method is based on the approximation of the binary probability preference relation by the binary median preference relation. The method is verified using statistical modeling (the Monte Carlo method). The proposed approach can be used for ranking nonreusable and reusable objects.
A new method of pinpointing dielectric fluid leaks on pipe-type and self-contained cables using perfluorocarbon tracer (PFT) is presented. The method has successfully been used on the Con Edison transmission system to locate leaks of dielectric fluid on both types of cables. Application of the PFT technique does not require feeder deenergization and provides major advantages over the conventional method of freeze and pressure testing. Description of the method and results of field application are presented in the paper.
Skip to Content Cancer Control and Population Sciences Home Applied Research Home Risk Factor Monitoring and Methods Home Diet Usual Dietary Intakes: Background The NCI Method Details of the NCI Method Food Intakes, US Population, 2001-04 Selected Intakes
Skip to Content Cancer Control and Population Sciences Home Applied Research Home Risk Factor Monitoring and Methods Home Diet Usual Dietary Intakes: Background The NCI Method Details of the NCI Method Food Intakes, US Population, 2001-04 Selected Intakes
A constructive method is proposed to solve a class of massive Feynman integrals within the Negative Dimensional Integration Method. The results are compared with the ones given by known positive D models and expressed in terms of dimensionally and analytically regularized integrals 3 refs.
Susceptibility disks impregnated with 35 different antibiotics were assayed by the current Code of Federal Regulations method and by a new method employing an agar overlay. The new...Full Text Available
The applicability of two nuclear analytical methods: radionuclide X-ray fluorescence analysis and radiometric titrations based on precipitate formations was studied in order to determine the heptacaine hydrochloride in solutions. The applied methods were evaluated based on the obtained sensitivity values.
The applicability of two nuclear analytical methods: radionuclide X-ray fluorescence analysis and radiometric titrations based on precipitate formations was studied in order to determine the heptacaine hydrochloride in solutions. The applied methods were evaluated based on the obtained sensitivity values. (author).
Adenosine triphosphate (ATP) is an indicator of living biomass in marine particulates. This report details the method used by Lawrence Berkeley Laboratory to analyze particulate ATP in samples taken from oligotrophic, tropical ocean waters. It represents a synthesis of previously published methods.
On the problem of alarm when parts are falling in nuclear power plant, the artificial neural network (ANN) alarm method based on the signal time-frequency characteristics was developed. The method was realized by the improved BP algorithm, and demonstrated with the data from simulation experiments
Methods of acidizing a subterranean well formation, acidizing compositions, and sequestering additives for preventing the precipitation of metal compounds in the formation are described. Use of the methods and chemicals described should lead to improved formation permeability as compared to use of previous methods and chemicals. 12 claims.
Abstracts are presented of 63 papers on the following topics: large-scale optimization, interior-point methods, algorithms for optimization, problems in control, network optimization methods, and parallel algorithms for optimization problems.
A binary mixture of imipramine HCl and chlordiazepoxide was determined by three different spectrophotometric methods. The first method involved determination of imipramine HCl and chlordiazepoxide using...Full Text Available
... Abstract : Interlaboratory evaluation of the Radiant Panel Method (ASTM E 162-67) for flame spread testing of two flexible foam and one hardboard ...
... explosive (shotgun shells, etc.) method of forming is being replaced--for the most part--by the electri- cal discharge and magnetic forming methods. ...
X-ray diffraction enhanced imaging (DEI) is applied to inspect internal structures of weakly absorbing low-Z sample. How to extract phase information from raw images measured in different positions of rocking curve is the key problem of DEI. In this paper, we present an effective extraction method called polynomial curve fitting method, in order to extract accurate information angular in a fast speed. It is com- pared with the existing methods such as multiple-images statistical method and Gaussian curve fitting method. The experiments results on a plastic cylinder and a black ant at the Beijing Synchrotron Radiation Facility prove that the polynomial curve fitting method can obtain most approximate refraction-angle values and its computation speed is 10 times faster than the Gaussian curve fitting method. (authors)
Metastable and somatically heritable patterns of DNA methylation provide an important level of genomic regulation. In this article, we review methods for analyzing these genome-wide epigenetic...Full Text Available
The invention relates to a method for purifying a gas mixture containing at least one undesirable gas compound utilizing certain sulfonamide or sulfamide solvents.
The present invention describes surfactants of formula (I), ##STR00001## wherein R, R.sub.N, and m are defined herein, processes for their preparation, and methods for their decomposition.
The possibility of gamma-absorption identification of the analyzed substance is considered. the basic provisions of the proposed method are concentrated on the example of carbohydrates and hydrocarbons. The above method is tested experimentally on polyethylenes and polystyrene
Apparatus and method are described for the vaporization of liquid fuel oils to produce a gaseous mixture suitable for burning in a burner normally designed for operation utilizing natural gas.
Dynamic clamp is a powerful method that allows the introduction of artificial electrical components into target cells to simulate ionic conductances and synaptic inputs. This method is based...Full Text Available
The aim of the present study was to describe the distribution and remobilization of plutonium (Pu) in the sediments off the Rhone river mouth. Most of the {sup 238}Pu and {sup 239,240}Pu isotopes introduced into the Rhone River were discharged by the liquid effluents released from the Marcoule reprocessing plant, located 120 km upstream the river mouth. Due to its high affinity for particles and its long half life, {sup 238}Pu is a promising tracer to follow the dispersion of particulate matter from the Rhone River to the Mediterranean Sea. During the 3 REMORA cruises, sediment samples were specifically collected in the Rhone pro-delta area and more offshore on the whole continental shelf of the Gulf of Lions. The measurements of alpha emitters gave a first detailed spatial distribution of Pu isotope concentrations in surface sediments off the Rhone mouth. Using {sup 137}Cs concentrations and their correlations with Pu isotopes, we were able to give a first ...
Slope stability can be a major problem during the construction of surface facilities. Cutting into existing ground disturbs the mechanics of the surrounding area, which can result in landslides and rock falls. This practical reference gives you the comprehensive information you need for slope stability analysis, suitable methods of analysis with and without the use of computers, and examples of common stability problems and stabilization methods for cuts and fills. It includes detailed discussions of methods used in slope stability analysis, including the Ordinary Method of Slices, Simplified Janbu Method, Simplified Bishop Method, Spencer`s Method, other limit equilibrium methods, numerical methods, total stress analysis, effective stress analysis, and the use of computer programs to solve problems. ...
The radionuclide X-ray fluorescence and particle induced X-ray emission methods were used for rapid and nondestructive analysis of metallic glasses. The methods were compared for accuracy and precision with the atomic absorption method. Some results of the analyses of Fe_xNi_8_0_-_xB_2_0 materials are briefly reviewed. The distribution of elements along the width as well as the length and a qualitative analysis of the composition of material surfaces are considered. (author).
A simple and effective method is presented for the sizing and passage apportionment of multistream plate-fin heat exchangers. Methods for passage arrangement are discussed, and it is shown that a symmetric or mixed passage arrangement is more efficient than a segregated arrangement. A method for assessing the relative merits of various passage arrangements is presented. The use of the methods is illustrated through a worked example.
The results for development of methods and computer programs for integrated optimization of parameters of perspective fast reactors are given. The possibilities of the program for the reactor campaign calculation are analysed. This program is based on utilisation of the Bubnov-Galerkin method and Wigner disturbance theory. The possibility of application of approximation methods for the optimization researches is discussed. The results of development of the programs for complex reactor computations with account of control rods system and change of physical parameters in the reactor campaign are discussed. (author).
Two methods for measuring indoor radon concentrations using activated charcoal have been tested. The first method is the well-known technique with direct gamma-measurements on the exposed canister after the sampling period. The other method uses a thermoluminescence dosemeter placed in the charcoal canister, giving an integrated value of the radon concentration.
Stability constants for uranium-tetracycline complexes were determined by the method of average number of ligands, the method of limiting values, the method of two parameters and the method of weighted least squares. Solvent extraction technique was used to obtain experimental data. (author). 10 refs.; 5 figs.
A rapid and accurate method for the direct simultaneous determination of nitrate and nitrite is proposed. The method is applied to the determination of nitrate and nitrite in rainwater and wastewater without preliminary separation. The determinations are performed by a CPA matrix method with ultraviolet spectrophotometric detection. The results obtained are in agreement with those obtained by conventional methods for the determination of nitrate and nitrite.
Pyrheliometric methods are described (particularly methods for measuring the solar constant), and theoretical and experimental studies in this field are surveyed and systematized. Particular attention is given to the analysis of instruments intended for pyrheliometers used as standards, reference instruments, and solar-constant meters is examined, and consideration is given to methods for determining the thermal-radiation properties of absorbing coatings and methods for calculating the absorption coefficients of cavity receivers.
The basic objective of this project was to consider a large class of matrix computations with particular emphasis on algorithms that can be implemented on arrays of processors. In particular, methods useful for sparse matrix computations were investigated. These computations arise in a variety of applications such as the solution of partial differential equations by multigrid methods and in the fitting of geodetic data. Some of the methods developed have already found their use on some of the newly developed architectures.
Due to biological effects of magnetic fields of high voltage transmission lines and induced effects on has pipe line, telecommunication system and interference with sensitive electronic equipment, many effort have been done to reduce transmission lines magnetic fields and several ideas have been introduced. In this paper we review three methods: phase split, shielded and compacted line methods. With aid of a developed software programme these methods are then applied to transmission lines and the results are analyzed.
Reported on here are studies of various methods for liquefying coal. Hydropyrolysis as an alternative method for producing liquid hydrocarbons and a carbon enriched char is discussed. Other methods described involve supercritical gas extraction of coal and use of natural gas as a hydrogenating agent. Relevant waste water treatments are discussed as well. 65 refs., 9 figs.
A method is provided for detecting pathological macromolecules in a patient. The method is comprised of the following: obtaining body fluid from the patient; pretreating the body fluid; subjecting the pretreated body fluid to size-exclusion chromatography to create an excluded fluid; and analyzing the excluded fluid to detect macromolecules having a predetermined molecular weight. The method also allows for comparing elution spectra with reference spectra of suspect pathologic proteins.
A new method for the determination of the cmc using a dialysis technique which allows monometric species to diffuse through but no micelles has been applied for determining the mixed micelle composition. The method is based on determining the amount of surfactant that diffuses through at two different times which allows for the calculation of the cmc by use of the appropriate equation. This method requires the preparation of only one concentration of solution and lends itself particularly well to the determination of the composition of mixed micelles. (orig.)
Objective: To develop a computerized method of internal dose estimation on radiation protection. Methods: Based on MIRD mathematic model of the organs and by means of the programming language of MS Visual Basic 6.0, a computer program of dose estimation in internal radiation was developed for radiation protection. Results: The computerized method of dose estimation for internal radiation was completed. Conclusions: This computerized method is very convenient for internal radiation dose estimation of several aspects. It can also be used in radiation accident. (authors)
A procedure for the determination of lead in various biological and environmental samples by "2"0"3Pb radioisotope dilution substoichiometric method is presented. The accuracy of the method by comparison with the literature values of reference materials appears to be good. The standard deviation of the method is less than 10%, and detection limit is about 0.1 #mu#g of lead. (author) 5 refs.
A comparison was made of Parr bomb ion chromatographic and titrimetric methods to determine sulfur in fuel oils. The two methods are comparable in precision and accuracy. When rapid sulfur determination in a number of samples is desired, the titrimetry method appears to be an appropriate choice between the two methods. l3 tables.
In this paper we present a new efficient sixth-order scheme for nonlinear equations. The method is compared to several members of the family of methods developed by Neta (1979) [B. Neta, A sixth-order family of methods for nonlinear equations, Int. J. Comput. Math. 7 (1979) 157-161]. It is shown that the new method is an improvement over this well known scheme.
In this article, we propose a model selection method, the Bayesian composite model space approach, to map quantitative trait loci (QTL) in a half-sib population for continuous and binary traits. In our method, the identity-by-descent-based variance component model is used. To demonstrate the performance of this model, the method was applied to map QTL underlying production traits on BTA6 in a Chinese half-sib dairy cattle population. A total of four QTLs were detected, whereas only one QTL was identified using the traditional least square (LS) method. We also conducted two simulation experiments to validate the efficiency of our method. The results suggest that the proposed method based on a multiple-QTL model is efficient in mapping multiple QTL for an outbred half-sib population and is more powerful than the LS method based on a single-QTL ...
The Energy Laboratory of the University of Houston has developed a computer simulation program called CREAM (Cavity Radiation Exchange Analysis Model) for application to the solar central receiver system. CREAM contains a geometric configuration factor generator based on Nusselt's method. A formulation of Nusselt's method provides the basis for a FORTRAN subroutine NUSSELT. Numerical results from NUSSELT are compared to analytic values and values from Sparrow's method. Sparrow's method is based on a double contour integral and its reduction to a single integral which is a approximated by Gaussian methods. Nusselt's method is adequate for the intended engineering applications, but Sparrow's method is an order of magnitude more efficient in many situations.
This paper proposes the use of particle swarm optimization method (PSO) for finite element (FE) model updating. The PSO method is compared to the existing methods that use simulated annealing (SA) or genetic algorithms (GA) for FE model for model updating. The proposed method is tested on an unsymmetrical H-shaped structure. It is observed that the proposed method gives updated natural frequencies the most accurate and followed by those given by an updated model that was obtained using the GA and a full FE model. It is also observed that the proposed method gives updated mode shapes that are best correlated to the measured ones, followed by those given by an updated model that was obtained using the SA and a full FE model. Furthermore, it is observed that the PSO achieves this accuracy at a computational speed that is faster than that by the GA and a full FE ...
The objectives of this study were to develop an accurate and precise method for cholesterol quantification in meat samples based on modifications made to an existing procedure (AOAC Official Method 994.10), and to apply this modified method to evaluate cholesterol levels in longissimus muscles (LM) from Angus (AN, n=5), Brahman (BR, n=4), and Romosinuano (RM, n=9) breeds. Validation of this method was performed using a meat homogenate (Standard Reference Material 1546) from National Institute of Standards and Technology (NIST), and LM samples from the three breeds with fat contents ranging from 2.4% to 9.3%. The results indicated that the modified method was accurate with cholesterol recovery exceeding 95%. The method was also found to be precise with an average coefficient of variation of...
Discussed in this report is a wavefield simulation in the 3-dimensional seismic survey. With the level of the object of exploration growing deeper and the object more complicated in structure, the survey method is now turning 3-dimensional. There are several modelling methods for numerical calculation of 3-dimensional wavefields, such as the difference method, pseudospectral method, and the like, all of which demand an exorbitantly large memory and long calculation time, and are costly. Such methods have of late become feasible, however, thanks to the advent of the parallel computer. As compared with the difference method, the pseudospectral method requires a smaller computer memory and shorter computation time, and is more flexible in accepting models. It outputs the result in fullwave just like the difference method, ...
In this thesis, a new ab-initio method for molecular dynamics within the framework of density functional theory was developed and implemented. It is strongly related to the projector-augmented-wave method (PAW) by P. Bloechl, but also includes elements of a pseudocharge method proposed by M. Weinert for the full-potential linearized augmented plane wave method (FLAPW). Like the FLAPW-method, the PAW-method is an all-electron method. In the later case, the hamiltonian takes quite a simple form similar to the one obtained when using normconserving Kleinman-Bylander-type pseudopotentials or ultrasoft Vanderbilt pseudopotentials. The PAW-method allows for an efficient calculation of systems containing virtually any element of the periodic table, including those which require high numerical effort when treated using ...
A new microdensitometry method for quantitative assessment of bone mineral content using Fuji computed radiography (FCR) was developed and the results were compared with those obtained by the conventional film-screen method. Using both methods, X-ray pictures of the 2nd metacarpal bone were taken with a reference aluminum step wedge in nine normal subjects and nine parameters representing the width and density of bone marrow and cortex were calculated in middle of the bone shaft. Interobserver reproducibility assessed for three parameters was significantly higher in the FCR method than the conventional one. The value of {Sigma}GS computed by the FCR method, that is equivalent to the net bone density of the transverse section of the shaft, showed higher correlation with the one obtained by computed tomography in comparison with the conventional method. In our FCR ...
A new microdensitometry method for quantitative assessment of bone mineral content using Fuji computed radiography (FCR) was developed and the results were compared with those obtained by the conventional film-screen method. Using both methods, X-ray pictures of the 2nd metacarpal bone were taken with a reference aluminum step wedge in nine normal subjects and nine parameters representing the width and density of bone marrow and cortex were calculated in middle of the bone shaft. Interobserver reproducibility assessed for three parameters was significantly higher in the FCR method than the conventional one. The value of #SIGMA#GS computed by the FCR method, that is equivalent to the net bone density of the transverse section of the shaft, showed higher correlation with the one obtained by computed tomography in comparison with the conventional method. In our FCR ...
Two different methods for streamlined life cycle assessment (LCA) are described: the MECO-method and SLCA. Both methods are tested on an already made case-study on cars fuelled with petrol or ethanol, and electric cars with electricity produced from hydro power or coal. The report also contains some background information on LCA and streamlined LCA, and a deschption of the case study used. The evaluation of the MECO and SLCA-methods are based on a comparison of the results from the case study as well as practical aspects. One conclusion is that the SLCA-method has some limitations. Among the limitations are that the whole life-cycle is not covered, it requires quite a lot of information and there is room for arbitrariness. It is not very flexible instead it difficult to develop further. We are therefore not recommending the SLCA-method. The ...
An exact solution method for the free vibration problem of thin circular cylindrical shells is presented. The differential equations of motion are solved directly with the use of simple Fourier series as the modal displacement functions. Stokes' transformation is exploited to obtain correct series expressions for the derivatives of the Fourier series. From this method an explicit expression of the exact frequency equation can be obtained for any kind of boundary conditions. The accuracy of the present method is checked against available data. The proposed method is then used to find the modal characteristics of the thermal liner of the Fast Test Reactor (FTR). The numerical results obtained are compared with finite element method solutions. (auth)
According to enactment of reduced dose limit based on ICRP-60, the calculation of Derived Release Limits(DRL) on Wolsung NPPs was carried out. There are two methods of determination on DRL; that is MPC(Maximum Permissible Concentration) method and system analysis method. In order to use the system analysis method, lots of environmental data are necessary and complicated exposure pathway are considered. So we intend to apply MPC method that is sort of simple. In addition the calculated results were compared with derived release limit on Canadian nuclear power plant.
Approximate methods are presented for solving nonlinear boundary value problems with an unknown (free) boundary, such as the Stefan problem in heat conductivity. Examples of this kind of problems in thermal physics, hydrodynamics, elasticity, and plasma physics are examined. Attention is given to the principal computational methods for solving stationary problems for second- and fourth-order elliptic equations, such as the domain transformation and penalty methods. To illustrate the capabilities of the methods presented here, examples of numerical solutions are presented for various specific applied problems. 255 references.
We present a numerical method for computing diffusive transport on a surface derived from image data. Our underlying discretization method uses a Cartesian grid embedded boundary method for computing the volume transport in region consisting of all points a small distance from the surface. We obtain a representation of this region from image data using a front propagation computation based on level set methods for solving the Hamilton-Jacobi and eikonal equations. We demonstrate that the method is second-order accurate in space and time, and is capable of computing solutions on complex surface geometries obtained from image data of cells.
A Monte Carlo method called transient curve fitting method was developed to calculate a eigenvalues by first simulating the existing neutrons and precursors in the system, then calculating the Eigen-distribution of neutron flux and calculating the a eigenvalues using the transient results based on the Eigen-distribution by the code TMCC. The results of this method are tested by calculating Godiva Benchmark problems and they agree well with the benchmark results. Then the reasonable results of Subcritical Facility in Tsinghua University are given by TMCC, and the results are compared with the experimental results measured by Rossi-a method. Even in the deep subcritical cases, the method can give results consistent with experimental results. (authors)
Dictionary lookup methods are popular in dealing with ambiguous letters which were not recognized by Optical Character Readers. However, a robust dictionary lookup method can be complex as apriori probability calculation or a large dictionary size increases the overhead and the cost of searching. In this context, Levenshtein distance is a simple metric which can be an effective string approximation tool. After observing the effectiveness of this method, an improvement has been made to this method by grouping some similar looking alphabets and reducing the weighted difference among members of the same group. The results showed marked improvement over the traditional Levenshtein distance technique.
This paper discusses key methods for sustaining quality engineering data, the fundamental principles that these methods are based on, and the methods for supporting the performance of nuclear power plants by the provision of quality engineering data at all times. The concept of an 'engineering data foundation', and a Configuration Management data model are developed. The concepts and methods for managing the integrity of engineering data across many different databases and document systems are developed, including the key concepts of data-positions and data-values, Master Data and Copy Data, and the concept of a 'partnership between people and technology'. (author). 7 refs., 1 tab., 2 figs.
The susceptibility to intergranular corrosion of different heats of Alloy 800 was evaluated by three different methods: the ASTM A 262 Practice E (or modified Strauss test), the Electrochemical Potentiokinetic Reactivation method, and by magnetic-susceptibility measurements. Reasonably good agreement was found between the sensitization areas as defined by the three methods in the TTS diagrams. In some cases the area defined by the Strauss test was slightly smaller than that determined by the other two tests. The differences might be explained by the fact that the methods present different sensitivities to the chromium concentration at the grain boundaries. 27 references, 11 figures, 3 tables.
The paper describes an application of the tree classification method Random Forest (RF), as used in the analysis of data from the ground-based gamma telescope MAGIC. In such telescopes, cosmic gamma-rays are observed and have to be discriminated against a dominating background of hadronic cosmic-ray particles. We describe the application of RF for this gamma/hadron separation. The RF method often shows superior performance in comparison with traditional semi-empirical techniques. Critical issues of the method and its implementation are discussed. An application of the RF method for estimation of a continuous parameter from related variables, rather than discrete classes, is also discussed.
The goal of the book is to summarize those methods for evaluating Feynman integrals that have been developed over a span of more than fifty years. The book characterizes the most powerful methods and illustrates them with numerous examples starting from very simple ones and progressing to nontrivial examples. The book demonstrates how to choose adequate methods and combine evaluation methods in a non-trivial way. The most powerful methods are characterized and then illustrated through numerous examples. This is an updated textbook version of the previous book (Evaluating Feynman integrals, STMP 211) of the author. (orig.)
Stabilized formation temperatures were estimated at different depths in 40 wells from the Los Humeros geothermal field, Mexico, using the Horner and the spherical radial flow (SRF) methods. The results showed that the Horner method underestimates formation temperatures, while the SRF method gives temperatures that are closer to the true formation temperatures. This was supported by numerical simulation of a combined circulation and shut-in period in several wells, and results for well H-26 are presented. Numerical reproduction of logged temperature is more feasible if an initial temperature profile based on the SRF method is employed instead of using an initial temperature profile based on the Horner method. (Author)
With the mentioned method to analyse O-tyrosine with HPLC/fluorescence-detection, the irradiation of chicken meat can be determined in a simple and fast way. The formation of o-tyrosine is proportional to the applied dose but because it is also depending on the applied dose rate and the temperature during the irradiation, it is not possible to control the irradiation dose. Since unirradiated chicken can contain little amounts of o-tyrosine and to confirm some results, a second method is needed. Together with one of the other mentioned methods (analysis of the volatiles or esr-spectroscopy) it is possible to recognize irradiated chicken with a high security. (author).
The stability-enchancing two-step (SETS) method has been used successfully in the Transient Reactor Analysis Code (TRAC) for several years. The method consists of a basic semi-implicit step combined with a stabilizer step that, taken together, eliminate the material Courant stability limit associated with standard semi-implicit numerical methods. This approach toward stability requires significantly fewer computational operations than a fully implicit method, but currently maintains the first-order accuracy in space and time of its semi-implicit predecessors.
Method is proposed for expanding the pile foundation elastic analysis method (displacement method) to cover a larger displacement region, and its appropriateness is verified by a field test. In this report, stability calculation is discussed in which the present displacement method is expanded by assuming an equivalent plastic hinge on the pile head and by replacing the soil spring in the large displacement region with an equivalent linear elastic spring. A static horizontal loading test is conducted for a foundation using a real pile, which is an application of this method. On the assumption that a hinge is generated on the pile head, the pile spring constant of the current displacement method is replaced with a value that takes into consideration the plastic hinge region, and this enables the analysis of pile behavior even after breakdown. This ...
In principle four different methods (ultrasound, microwaves, {gamma}-radiation and x-rays) are available for the non-destructive testing of refractories. Three of these methods, i.e. ultrasound, microwaves and {gamma}-radiation, are in use by different producers of AZS materials to carry out the quality control of their products. This paper will compare the three methods on the basis of the physical properties, present the existing devices, and show the advantages as well as the limits of the different methods. {gamma}-radiography, the oldest method in use, has one main disadvantage, which is the requirement of protection against radioactive radiation. Furthermore, while cracks and cavities can be detected with this method, structural changes can not be monitored. Therefore, the ultrasonic method was developed that allows to detect ...
This study assesses the current state of undergraduate instruction in empirical research methods in communication and offers recommendations for enhancing such instruction. Responses to an online questionnaire were received from 149 communication-related programs at four-year colleges and universities. Just over 85% of responding programs offered an empirical methods course. Although the course often covered both qualitative and quantitative methods, instruction was heavily slanted toward quantitative methods and topics common to both qualitative and quantitative inquiry. The empirical methods course was usually required for graduation, but it was typically not well integrated with the rest of the curriculum and taken late in students' undergraduate careers. Additional analyses examined st...
Deals with slope stability problems met in the D coalfield of the Tamnava-Iztok surface coal mine where 171 Mt of brown coal have been excavated and 520 Mm{sup 3} of overburden. Six geomechanical methods were used to verify the reliability of slope angels (Hoek, Froehlich, Janbu, Bishop, Reame and Swase) along with the theory of finite elements. All calculations were accomplished by means of computers. It was found that the Ream method (combined Bishop and Fellenius method) provides the most reliable results in determining general slope angles. The Janbu method is mostly suited for locations with complicated geological conditions (multi-layer benches); the Swase method may be considered as most reliable for locations with simple geological conditions and for spoil banks. 5 refs.
The difficulty and unstability of the parameter estimation of mass action model for radioimmunoassay are the major obstacles to its application in routine work. A unique robust curve fitting method for the mass action model was introduced. large numbers of simulated data were generated with Monte Carlo method to compare the accuracy and robustness of the robust fitting and the least squre fitting (Marquardt method) of the mass action model. The results demonstrated that the new robusst method significantly increased the accuracy and reliability of data processing with the mass action model. It also markedly reduced the influence of outliers in the fitting of RIA data, and it was always 'convergent'. This robust method could also be applied to other mathematical models which can be transformed into high degree equations and no initial estimates are needed for curve fitting.
In this paper, research on pass schedule of tandem cold mill (TCM) is carried out. According to load (reduction, rolling force, motor power) balance, non-linear equations set with variables of inter-stand thickness is constructed. The pass schedule optimization is carried out by solving the non-linear equations set. As the traditional method, the Newton-Raphson method is used for solving the non-linear equations set. In this paper a new simple method is brought up. On basis of the monotone relations between thickness and load, the inter-stands thickness is adjusted dynamically. The solution of non-linear equations set can be converged by iterative calculation. This method can avoid the derivative calculation used by traditional method. So, this method is simple and calculation speed is high. It is suitable for on-line control. (author)
In this paper, research on pass schedule of tandem cold mill (TCM) is carried out. According to load (reduction, rolling force, motor power) balance, non-linear equations set with variables of inter-stand thickness is constructed. The pass schedule optimization is carried out by solving the non-linear equations set. As the traditional method, the Newton-Raphson method is used for solving the non-linear equations set. In this paper a new simple method is brought up. On basis of the monotone relations between thickness and load, the inter-stands thickness is adjusted dynamically. The solution of non-linear equations set can be converged by iterative calculation. This method can avoid the derivative calculation used by traditional method. So, this method is simple and calculation speed is high. It is suitable for on-line control. (author)
In this paper, a time-domain equivalent circuit method is applied to solve dispersion of coupled-cavity travelling-wave tube (CCTWT). First, the time-domain circuit equations of CCTWT coupled-cavity chain are deduced from the equivalent circuit model. Then, the equations are solved numerically by fourth-order Runge-Kutta method and a program CTTDCP is developed using MATLAB. Last, a L-band CCTWT is calculated using CTTDCP and the cavity pass-band of this tube is computed to be 1.08-1.48 GHz, which is consistent with the experimental results and the simulation results of electromagnetic code and demonstrates the validity of the time-domain equivalent circuit method. In addition, a new design method which uses the equivalent circuit method and electromagnetic simulation together to optimize the cold cavity characteristics of CCTWT is proposed. (authors)
The present authors have previously developed a new method for Probabilistic Fracture Mechanics (PFM), which they call Recursive Distribution (RD) method. The method is based on the construction of the Lebesgue-Stieltjes measure through a deterministic mapping defining a crack growth process. In the present paper, its theoretical background is first discussed, and the Lebesgue decomposition of the measure is given. Then a numerical example of a Light Water Reactor (LWR)`s piping problem is solved by the present method, and the results are compared with those of the Monte Carlo (MC) method. In addition to leakage probability, a variation in stress cycles of the marginal distribution of an aspect ratio of a semi-elliptical surface crack is calculated, which will be used in a study on LBB evaluation.
Purpose - The purpose of this paper is to investigate the accuracy of different force calculation methods and their impact on mechanical deformations. For this purpose, a micrometer scaled actuator is considered, which consists of a micro-coil and of a permanent magnet (PM) embedded in a deformable elastomeric layer. Design/methodology/approach - For the magnetic field evaluation a hybrid numerical approach (finite element method/boundary element method (FEM/BEM) coupling and a FEM/BEM/Biot-Savart approach) is used, whereas FEM is implemented for the mechanical deformation analysis. Furthermore, for the magneto-mechanical coupling several force calculation methods, namely the Maxwell stress tensor, the virtual work approach and the equivalent magnetic sources methods, are considered and co...
A numerical analysis method for melting/solidification phenomena has been developed to evaluate a feasibility of several candidate techniques in the nuclear fuel cycle. Our method is based on the eXtended Finite Element Method (X-FEM) which has been used for moving boundary problems. Key technique of the X-FEM is to incorporate signed distance function into finite element interpolation to represent a discontinuous gradient of the temperature at a moving solid-liquid interface. Construction of the finite element equation, the technique of quadrature and the method to solve the equation are reported here. The numerical solutions of the one-dimensional Stefan problem, solidification in a two-dimensional square corner and melting of pure gallium are compared to the exact solutions or to the experimental data. Through these analyses, validity of the newly developed numerical analysis ...
The perceptual center (P-center) is fundamental to the timing of heterogeneous event sequences, including music and speech. Unfortunately, there is currently no comprehensive and reliable model of P-centers in acoustic events, so P-centers must instead be measured empirically. This study reviews existing measurement methods and evaluates two methods in detail?the rhythm adjustment method and a new method based on the phase correction response (PCR) in a synchronous tapping task. The two methods yielded consistent P-center estimates and showed no evidence of P-center context dependence. The PCR method appears promising because it is accurate and efficient and does not require explicit perceptual judgments. As a secondary result, the magnitude of the PCR is shown to vary systematically with ...
Although the radioreceptor method is widely used for estrogen receptor assay in human tissue, it has several limitations and a number of alternative methods are being explored. An immunohistochemical method of estrogen receptor assay using a specific antibody to estradiol has been proposed as a suitable alternative. The present study was designed to evaluate the validity of this method in detecting true estrogen receptors in human tumor tissue. Using radioiodinated antibody to estrogen, we have demonstrated that the estrogen antibody can detect the estrogen when it is bound to 4S type receptor but is unable to bind to estrogen when the hormone is bound to 8S type receptor. Our observations suggest that the immunohistochemical method of detection of intracellular cytosolic receptor for estrogen is not a suitable alternative to the currently used radioreceptor ...
A review of analytical design methods used for predicting reactor core flow and temperature distributions is presented with emphasis on LMFBR's. The paper also briefly describes and contrasts the methods used for LWR's. These methods are global analysis, subchannel analysis, distributed parameter, and hybrid analysis. The evolution of the local and subchannel analysis methods is presented. Data used for code validation are also presented. Current research and development needs are identified and discussed. Areas identified for future research and development include methods and expermental data for analysis of distorted bundles and natural convection. Methods that have been developed for predicting the safety performance of LMFBR's and LWR's are not within the scope of this paper.
In this paper, 0.75Pb(Fe2/3W1/3)O3-0.25PbTiO3-0.15 wt% MnO (0.75PFW-0.25PT-0.15 wt% MnO) ceramics are synthesized by two different methods, the conventional direct oxide synthesized (DS) method and two-step indirect synthesized (IS) method. The low-field dielectric responses are investigated by using the empirical law, the Curie-Weiss law, the modified-Landau theory and the spin-glass model. Due to the IS method, the lattice structure and the grain structure of the samples are changed. Furthermore, the dielectric properties are evidently modified. It is suggested that the ordering degree of B-site cations is enhanced by using the IS synthesized method.
This paper presents two imaging methods by using cross correlation. The one method images the subsurface by cross-correlation of the observed data and partial derivative seismograms calculated for a guessed model. The other method images the interface by use of cross-correlation of the virtual sources and the back propagated wave fields calculated from the observed data. Experimental tests show that both methods image subsurface interfaces well even if the guessed model is different from the true one. These imaging methods are reverse time migration that we perform cross-correlation as an imaging condition and have an advantage, as compared to conventional waveform inversion method, that images subsurface structure without iterative perturbation of the assumed model. (author). 18 refs., 15 figs.
We have developed an energy-extension method of a Bragg curve counter (BCC) at the high-energy end for the measurements of double-differential cross-sections (DDXs) of fragment productions induced by tens of MeV protons. In this method, we estimate the incident energies of the fragments penetrating a BCC on the basis of the energy loss and atomic number (Z). We applied this method to the DDX measurements of the {sup nat}C(p, Li) and {sup nat}C(p, Be) reactions induced by 70 MeV protons. The validity of this method has been confirmed by comparing the DDXs of beryllium with theoretical predictions of the PHITS code and the two-body kinematics. This method improves the energy acceptance of the BCC for light fragments twice as wide as that of a conventional method without remodeling of the BCC and any loss of the original advantages.
Abstract In 46 febrile neutropenic patients who had undergone haematopoietic stem cell transplantation, the fluorescence in situ hybridisation using peptide nucleic acid probes (PNA FISH), Gram stain/acridine orange leukocyte cytospin (Gram/AOLC), and differential time to positivity (DTP) methods were performed for detection of catheter related bloodstream infections (CRBSIs). As compared with the DTP method (which detected 11 patients with CRBSI), the PNA FISH and the Gram/AOLC methods detected ten of 11 CRBSI patients, resulting in a sensitivity, specificity, negative predictive value and positive predictive value of 91%, 100%, 97% and 100%, respectively, for the PNA FISH method as well as for the Gram/AOLC method.
In this work, a powerful analytical method, called He's parameter-expanding methods (HPEM) is used to obtain the exact solutions of non-linear modified Van der Pol's oscillator. The classical Van der Pol equation with delayed feedback and a modified equation where a delayed term provides the damping are considered. It is shown that one term in series expansions is sufficient to obtain a highly accurate solution, which is valid for the whole solution domain. Comparison of the obtained solution with those obtained using perturbation method shows that this method is effective and convenient to solve this problem. This method introduces a capable tool to solve this kind of non-linear problems.
A nodal integral method is derived for the monoenergetic, steady-state, fixed source neutron diffusion equation in hexagonal geometry based on a coordinate transformation that maps a parallelogram into a rectangle. The new hexagonal nodal diffusion method is implemented in the computer code HND where the discrete-variable equations are solved via an iterative scheme. Because the new method's equations are derived for a rhombus, they can be solved on a sequence of embedded meshes to study the method's error order. Indeed a preliminary numerical error analysis reveals a second-order error in the mesh size, and comparison with finite difference results obtained with the finite difference based BOLD-VENTURE code indicate the superior accuracy of our new nodal method.
This report is composed of the following two parts and appendix. (I) Improvement of the Method for Evaluating Reactivity Based on Monte Carlo Perturbation Theory: Theoretical formulation in Monte Carlo perturbation method had been checked, and then introduced into a calculation code. There are some cases that the results of the change of eigenvalues becomes positive or negative by changing the estimator, and there is no reasonable difference in the results between the conventional method, which does not consider the change of neutron source distribution caused by a perturbation, and the new method, which consider that change. Thus it is still necessary to check the Monte Carlo perturbation code. (II) Improvement of Nodal Transport Method for 3-D Hexagonal Geometry: We can accurately evaluate hexagonal geometry FBR core by nodal transport calculation code for hexagonal-Z geometry ...
Thalassaemic patients are in need of frequent assessment of bone age because of growth failure and pubertal disorders. To compare the ''rapid'' Greulich and Pyle (G and P) method with the third edition of the Tanner and Whitehouse (TW3) method for determining skeletal maturity and predicting final height in thalassaemic patients. A total of 191 radiographs from 58 patients (28 male, 30 female) were retrospectively evaluated by two investigators, one for each method. In 47 radiographs from 15 patients having attained their adult height, predicted final height was calculated according to each method. The mean bone ages determined by both the G and P and TW3 methods were lower than mean chronological age, although the differences were not statistically significant (10.04 {+-} 3.69 years and 9.98 {+-} 3.39 years vs. 10.78 {+-} 3.96 years, ...
California s major energy utilities and the California Energy Commission (CEC) are seeking to allocate capital that yields the greatest return on investment for energy infrastructure that meets any part of the need for reliable supplies of energy. The utilities are keenly interested in knowing the amount of electrical energy savings that would occur if cool roof color materials are adopted in the building market. To meet this need the Oak Ridge National Laboratory and the Lawrence Berkeley National Laboratory (LBNL) have been collaborating on a Public Interest Energy Research (PIER) project to develop an industry-consensus energy-savings calculator. The task was coordinated with an ongoing effort supported by the DOE to develop one calculator to achieve both the DOE and the EPA objectives for deployment of cool roof products. Recent emphasis on domestic building energy use has made the work a top priority by the Department of Energy s (DOE) Building Technologies Program. The Roof ...
UV, first, second and third derivative spectrophotometric methods have been developed for the determination of ezetimibe in pharmaceutical formulation. The solutions of standard and sample were prepared...Full Text Available
1. The short duration cerebrovascular perfusion method for measuring permeability of the blood-brain barrier has been adapted to measuring transport into the retina. 2. The method has been characterized...Full Text Available
ObjectivesThe objective of this paper is to describe the complex mixed-methods design of a study conducted to assess health-related quality of life (HRQOL) outcomes...Full Text Available
Overview Package  Class Use Tree Deprecated Index Help  PREV CLASS  NEXT CLASS FRAMES   NO FRAMES SUMMARY:  INNER | FIELD | CONSTR | METHOD DETAIL:  FIELD | CONSTR | METHOD gov.nih.nci.dc.database Class SearchCriteria java.lang.Object |
An approximate solution was proposed in which a sensitivity analysis by the storage and release of heat was performed for the subject issues and in which an operating method was thereby determined for the equipment constituting the system by means of a linear programming. Accordingly, a heat storage type energy supply system for a district cooling and heating was taken up as a concrete object to be examined. This system consisted of a gas turbine generator, initial power receiving equipment, gas boiler, electric heat pump for ice heat storage, cooling tower, heat exchanger, steam absorbing refrigerating machine, ice heat storage tank, cold and warm water heat storage tank, etc. As a result of comparison between the proposed method and the resolving method, the former showed -0.92 to 2.58% in the increase in the operating cost compared with the latter. A case where the operating cost of the resolving ...
A high-purity, intense, fast-neutron source has been developed at our laboratory. We describe two inexpensive, straightforward methods of determining the total number of neutrons produced and we review precautions to be taken in applying these methods. (orig.).
A general method is given for the construction of gauge-fixed actions for theories with local gauge symmetries. The method is based on the single requirement that the space of fields carries an irreducible representation of the Sp(2)-BRST algebra, with respect to which the resultant actions are then automatically invariant.
The parameters including knot numbers, knot positions and the weights associated with the systematic errors in the cubic spline curve fitting method were discussed. The conditions of using fitting criterion were given as well.
We propose new method of assessment of histological images for medical diagnostics. 2-D image is preprocessed to form 1-D landscapes or 1-D signature of the image contour and then their complexity is...Full Text Available
I present results for the mass spectrum of excited baryons and pentaquarks using overlap fermions and Bayesian curve-fitting method; and magnetic moments and polarizabilities for a variety of hadrons in the background field method.
I present results for the mass spectrum of excited baryons and pentaquarks using overlap fermions and Bayesian curve-fitting method; and magnetic moments and polarizabilities for a variety of hadrons in the background field method.
We have evaluated the performance of two rapid, low-cost methods for the detection of ofloxacin (OFX) resistance with 95 Mycobacterium tuberculosis isolates from countries with high...Full Text Available
Specificity of the pulses mean frequency measurement (the pulses being generated in a stochastic process) is described. Status of the domain of analog frequency meters is presented. Methods of increasing accuracy of such meters are discussed.
Specificity of the pulses mean frequency measurement (the pulses being generated in a stochastic process) is described. Status of the domain of analog frequency meters is presented. Methods of increasing accuracy of such meters are discussed. (author).
The possibility of studying the adsorption of acetic acid vapour on coal by the method of multiple attenuated total internal reflection by two proposed procedures has been shown.
This neutron reflectometry study evaluates the structures resulting from different methods of preparing polymer-cushioned lipid bilayers. Four different techniques to deposit a dimyristoylphosphatidylcholine...Full Text Available
In the present work, fast disintegrating tablets of prochlorperazine maleate were designed with a view to enhance patient compliance by direct compression method. In this method mucilage of Plantago...Full Text Available
Background and objectives: Patients receiving dialysis have a high burden of cardiovascular disease. Some receive coronary artery revascularization but the optimal method is controversial.Design,...Full Text Available
On the basis of the resolvent of a simple differential operator, a method for finding approximations to continuous functions is constructed. In this method, both the approximated function and its approximations satisfy the given integral boundary condition.
This paper proposes a novel method for computing linear basis images from tensor-valued image data. As a generalization of the nonnegative matrix factorization, the proposed method aims to approximate...Full Text Available
This thesis consists of five chapters, each of which is a self-contained unit. The first chapter overviews methods for electronic-structure calculations. Chapter 2 introduces a new method to generate a rapidly converging configuration expansion. The approach iteratively combines (1) a least-squares fitting of a configuration expansion to a many-body wave function with (2) a transfer-matrix method for projecting out the ground state. Results are shown to be equivalent to multiconfiguration Hartree-Fock. Results from test calculations are given for a simple finite difference model of the helium atom. In Chapter 3 the use of the finite-element method in electronic structure calculations is discussed. Chapters 4 and 5 discuss developments in Monte Carlo methods based on Hubbard-Stratonovich transformations. Chapter 4 introduces a canonical ensemble formulation of the ...
This article is about the network security defence method and technique at IHEP. Including: the experience, research result and application in network outlet security, server security, local network security, network security monitoring and collecting evidence, anti-virus etc
The generation of acidic mine drainage is based on the oxidation dissolution of sulfide minerals due to the contact of ores with the natural water and the air. Namely, the sulfuric acid promotes the dissolution of sulfide minerals and gangue minerals, and Fe{sup 2+} is further oxidized to turn into Fe{sup 3+}, which acts as an oxidizer for other sulfide minerals and promotes the dissolution of the same. This paper roughly describes a mine drainage treatment focusing on an Fe{sup 2+} neutralization method and an iron bacteria oxidation method. The iron bacteria oxidation method is a method of oxidizing Fe{sup 2+} into Fe{sup 3+} by using iron bacteria, and then removing Fe{sup 3+} with calcium carbonate. This method has been used for treating the drainage in the Sakuhara Mine and the former Matsuo Mine, with good results. The paper finally introduces, as power-saving low-cost mine ...
We successfully reproduce one of the French pipe whip experiments with the computer code WIPS. The WIPS results are in excellent agreement with the experimental data and the French computer code TEDEL. This justifies the use of its pipe element in conjunction with its U-bar element in a simplified method of impact analyses.
A method is proposed for operating bed waters in an oil well by injecting silanes into the near-face zone. It is distinguished by the fact that in order to improve the effectiveness of insulation, the silanes used are silanes of general formula Si /SUB n/ H /SUB 2n-n/ .
Method for description of X-ray radiation dose distribution based on semiempirical description of dose fields is suggested. At that dose field description parameters can be easily individualized for concrete X-ray device.
Method for inhibiting the formation of foulants on petrochemical equipment which involves adding to the petrochemical, during processing, a composition comprising a thiodipropionate and either a dialkyl acid phosphate ester or a dialkyl acid phosphite ester.
The present invention relates to a method of acidizing a subterranean formation or well bore employing an acidic solution containing a corrosion inhibitor composition comprising an inhibiting effective amount of an acetylenic alcohol, a quaternary ammonium compound, an aromatic hydrocarbon and an antimony compound.
In this paper method of constructing quasi-exactly solvable models of quantum mechanics is proposed. This method is based on the use of infinite-dimensional representations of simple and semi-simple Lie algebras.
In this paper, we present an iterative filtering method to estimate the background of noisy spectroscopic data. The proposed method avoids the calculation of the average full width at half maximum (FWHM) of the whole spectrum and the peak regions, and it can estimate the background efficiently, especially for spectroscopic data with the Compton continuum.
A method has been developed to predict the effects of mutations in the p53 cancer suppressor gene. The new method uses novel parameters combined with previously established parameters. The most important...Full Text Available
The neutron transport equation in Cartesian geometry possesses straight line characteristics along which the streaming operator can be written as a full differential in terms of the characteristic length. This idea was used by Lathrop to develop the step characteristic method, which he showed to be positive definite but less accurate than conventional Diamond-Difference schemes. Several authors since then have developed new methods utilizing the characteristic curves (including non-Cartesian geometry). A Linear Characteristic Method, based on a more consistent linear representation of the incoming-surface and within-cell angular flux, has been developed and tested in two-dimensional geometry producing highly accurate and computationally efficient results. A similar linear method, with several modifications, was developed for three-dimensional Cartesian geometry, and implemented in ORNL`s production code ...
In the synthesis of the peptidyl-polymer corresponding to the sequence (57-100) of the ..beta.. chain of human hemoglobin on Teflon with radiationally grafted polystyrene a comparative study was made of different methods of fragment condensation. It was shown that the most effective methods are azide condensation and condensation with the use of complex F.
In the synthesis of the peptidyl-polymer corresponding to the sequence (57-100) of the #beta# chain of human hemoglobin on Teflon with radiationally grafted polystyrene a comparative study was made of different methods of fragment condensation. It was shown that the most effective methods are azide condensation and condensation with the use of complex F.
Objective: The aim of this study was to characterize using flow cytometry cultured human primary keratinocytes isolated from the epidermis and hair follicles by different methods. Methods:...Full Text Available
Transduction method developed by the research coordinator and Prof. Muroga is one of the most popular methods to design large-scale integrated circuits, and thus used by major design tool companies in USA and Japan. The major objectives of the research is to improve capability and utilize its reusable property by combining with CAD databases. Major results of the project is as follows, (1) Improvement of Transduction method : Efficiency, capability and the maximum circuit size are improved. Error compensation method is also improved. (2) Applications to new logic elements : Transduction method is modified to cope with wired logic and FPGAs. (3) CAD databases : One of the major advantages of Transduction methods is 'reusability' of already designed circuits. It is suitable to combine with CAD databases. We design CAD databases suitable for ...
AIM: To identify a method for efficient large-scale purification of functional hepatitis B virus polymerase (HBV-Pol) without addition of cellular factors.METHODS: Full-length HBV-Pol (843 amino...Full Text Available
The Electronic REference To access In vivo Concentrations (ERETIC) method was applied to 1H HR-MAS spectroscopy. The accuracy, precision, and stability of ERETIC as a quantitative...Full Text Available
This paper describes the method to estimate the true formation temperature using temperature recovery logging data after the well reach to total depth (T.D.). The method designated as ''Curve-fitting method (CFM)'' is based on mathematical model proposed by Middleton (1979, 1982). The accuracy and applicability of this method are evaluated with several field data and compared advantageously with the Horner-plot method. Then, real-time data acquisition system including interpretation software has also been successfully developed. As a conclusion, the followings are confirmed: (1) The developed CFM can be applicable to the estimation of the true formation temperature even using 24 hours temperature recovery data, although the Horner-plot method might need up to 120 hours recovery data, usually. (2) Though depending upon the ...
Surveys were conducted in one urban and two rural regions of the United Republic of Cameroon to estimate the annual incidence of paralytic poliomyelitis. Three different survey methods were used: a...Full Text Available
Electron spin resonance (ESR) studies have been performed on spin-labeled model membranes aligned using the isopotential spin-dry ultracentrifugation (ISDU) method of Clark and Rothschild. This method...Full Text Available
Motivation: Cell tracking is an important method to quantitatively analyze time-lapse microscopy data. While numerous methods and tools exist for tracking cells in 2D time-lapse images,...Full Text Available
A photon-induced x-ray fluorescence method allowing the simultaneous determination of iron, copper, zinc, bromine and rubidium in human blood and blood plasma samples is described. The method is reliable and has a good sensitivity for a wide range of elements. (author).
Descriptive assessment methods have been used in applied settings to identify consequences for problem behavior, thereby aiding in the design of effective treatment programs. Consensus has not been...Full Text Available
There are many methods to screen for abnormal amounts of proteinuria to identify patients at risk for progression of renal disease, but which method best predicts renal risk is unknown. Here, we analyzed...Full Text Available
A method for calculating plume rise above stack level is presented. The equations set forth by Briggs, which are presently the most popular for such calculations, are discussed. A method using 2 nomographs, simplifying the calculations is given. (JMT)
A new method for removing periodic background patterns from pictures is presented. The basic spatial frequency composition of the pattern is determined from an estimate of the power spectrum of the picture. A digital restoration filter is then created from a modified version of the power spectrum. The method is extremely effective and can be automated.
BackgroundMolecular docking methods are commonly used for predicting binding modes and energies of ligands to proteins. For accurate complex geometry and binding energy estimation,...Full Text Available
A sensitive and specific detection method was developed for Xanthomonas hyacinthi; this method was based on amplification of a subsequence of the type IV fimbrial-subunit gene fimA...Full Text Available
This article compared conceptual and empirical strengths of alternative methods for estimating racial disparities using non-linear models of health care access. Three methods were presented...Full Text Available
Two field-adapted colorimetric methods for measuring the antimalarial drug chloroquine in urine are described. Both are modifications of the method of Saker and Solomons for screening urine for phencyclidine...Full Text Available
A method is presented to derive the absolute dimensions of early-type detached binaries by combining the observed parameters with results of evolutionary computations. The method is used to obtain the absolute dimensions of nine close binaries. We find that most systems have an initial masss ratio near 1.
1. An acid ninhydrin reagent was found to react specifically in forming a pink product (Emax. 560mμ) with cysteine. 2. The method was highly sensitive for the determination...Full Text Available
In order to reduce the length and to increase the effectiveness of processing, the proposed method for acetic processing of an electric centrifugal well pump calls for covering the pressure line during the curing and periodically starting the pump.
A simplification of Sandell's method for estimating nickel in urine is described. Nickel is a normal constituent of most articles of food and between 0·01 and 0·03 p.p.m. are found in...Full Text Available
This article describes process evaluation methods for the Pool Cool Diffusion Trial across four years. Pool Cool is a skin cancer prevention program that was...Full Text Available
...specifications of ASTM Grade 1 or Grade 2 fuel oils in ASTM Method D396-04, Standard Specification for Fuel Oils (incorporated by reference, see...ASTM Grade 4, Grade 5, or Grade 6 fuel oils in ASTM Method D396-04,...