WorldWideScience
1

A novel method to characterize the MTF in 3D for computed mammotomography  

Science.gov (United States)

A novel phantom has been developed to measure the modulation transfer function (MTF) in 3D for x-ray computed tomography. The phantom consists of three tungsten wires, positioned nearly orthogonal to each other. Simultaneous measurements of the MTF are taken at various locations along the three orthogonal reconstructed planes. Our computed mammotomography (CmT) system uses a Varian Paxscan 2520 digital x-ray detector which can be positioned anywhere in ~2pi steradian band and can have arbitrary trajectories. With a half-cone beam geometry and with the phantom positioned near the center of rotation, projection images are acquired over 360 degrees. Various 3D orbits are evaluated including vertical axis of rotation and saddle. Reconstructions were performed using an iterative ordered-subsets transmission algorithm on rebinned projection ...

2006-03-01

2

Study of spatial resolution in three-dimensional rotational angiography  

International Nuclear Information System (INIS)

In interventional radiology (IVR) of cerebral aneurysms, it is important to understand the form and physical relationships between the cerebral aneurysm and the surrounding vessels. However, because the vessels in the head area are highly complex, it can be difficult to comprehend the structure using conventional angiography. Therefore, three-dimensional rotational angiography (3D-RA) has been used in recent years. This article discusses studies of the spatial resolution of 3D-RA. We reconstructed 3D-RA of an acrylic slit phantom (slit widths: 0.5, 0.75, 1.0, 1.5 mm) and examined spatial resolution by visual evaluation and profile curves. When the slit phantom was arranged to avoid the effect of beam hardening, the spatial resolution of 3D-RA was found to be ...

2006-03-01

3

Ewald sphere correction for single-particle electron microscopy  

Energy Technology Data Exchange (ETDEWEB)

Most algorithms for three-dimensional (3D) reconstruction from electron micrographs assume that images correspond to projections of the 3D structure. This approximation limits the attainable resolution of the reconstruction when the dimensions of the structure exceed the depth of field of the microscope. We have developed two methods to calculate a reconstruction that corrects for the depth of field. Either method applied to synthetic data representing a large virus yields a higher resolution reconstruction than a method lacking this correction.

2006-03-15

4

Large Scale Laser Two-Photon Polymerization Structuring for Fabrication of Artificial Polymeric Scaffolds for Regenerative Medicine  

Science.gov (United States)

We present a femtosecond Laser Two-Photon Polymerization (LTPP) system of large scale three-dimensional structuring for applications in tissue engineering. The direct laser writing system enables fabrication of artificial polymeric scaffolds over a large area (up to cm in lateral size) with sub-micrometer resolution which could find practical applications in biomedicine and surgery. Yb:KGW femtosecond laser oscillator (Pharos, Light Conversion. Co. Ltd.) is used as an irradiation source (75 fs, 515 nm (frequency doubled), 80 MHz). The sample is mounted on wide range linear motor driven stages having 10 nm sample positioning resolution (XY--ALS130-100, Z--ALS130-50, Aerotech, Inc.). These stages guarantee an overall travelling range of 100 mm into X and Y directions and 50 mm in Z direction and support the linear scanning speed up to 300 mm/s. By moving the sample three-dimensionally the position of ...

2010-11-10

5

Multi-modality imaging of uveal melanomas using combined PET/CT, high-resolution PET and MR imaging  

Energy Technology Data Exchange (ETDEWEB)

We investigated the efficacy of combined FDG-PET/CT imaging for the diagnosis of small-size uveal melanomas and the feasibility of combining separate, high-resolution (HR) FDG-PET with MRI for its improved localization and detection. Patients, methods: 3 patients with small-size uveal melanomas (0.2-1.5 ml) were imaged on a combined whole-body PET/CT, a HR brain-PET, and a 1.5 T MRI. Static, contrast-enhanced FDG-PET/CT imaging was performed of head and torso with CT contrast enhancement. HR PET imaging was performed in dynamic mode 0-180 min post-injection of FDG. MRI imaging was performed using a high-resolution small-loop-coil placed over the eye in question with T2-3D-TSE and T1-3D-SE with 18 ml Gd-contrast. Patients had their eyes shaded during the scans. Lesion visibility on high-resolution FDGPET images was graded for confidence: 1: ...

2008-07-01

6

On the Metastable Level in Ni-like Ions  

Energy Technology Data Exchange (ETDEWEB)

The lowest excited level in Ni-like ions, 3d{sup 9}4s {sup 3}D{sub 3}, decays only via a magnetic octupole (M3) decay. They present calculated values of transition wavelengths and rates for ions with 30 {le} Z {le} 100. They have observed this line in Xe{sup 26+}, using the Livermore EBIT-I electron beam ion trap and a microcalorimeter, as well as a high-resolution flat-field grating spectrometer.

2004-09-14

7

A 3D tomographic EBSD analysis of a CVD diamond thin film  

Energy Technology Data Exchange (ETDEWEB)

We have studied the nucleation and growth processes in a chemical vapor deposition (CVD) diamond film using a tomographic electron backscattering diffraction method (3D EBSD). The approach is based on the combination of a focused ion beam (FIB) unit for serial sectioning in conjunction with high-resolution EBSD. Individual diamond grains were investigated in 3-dimensions particularly with regard to the role of twinning.

2008-09-15

8

Accurate positioning for head and neck cancer patients using 2D and 3D image guidance  

UK PubMed Central (United Kingdom)

Our goal is to determine an optimized image-guided setup by comparing setup errors determined by two-dimensional (2D) and three-dimensional (3D) image guidance for head and neck cancer (HNC)...Full Text Available

9

Near-surface 3D reflections seismic survey; Sanjigen senso hanshaho jishin tansa  

Energy Technology Data Exchange (ETDEWEB)

Faults are being actively investigated across Japan since the Great Hanshin-Awaji Earthquake. Discussed in this report is the application of the 3D near-surface reflection seismic survey in big cities. Data from trenching and drilling is used for the geological interpretation of the surroundings of a fault, and the reflection seismic survey is used to identify the position, etc., of the fault. In this article, when the results obtained from the experimental field are examined, it is found that the conventional 2D imaging reflection survey betrays the limit of its capability when the geological structure is complicated, that the 3D reflection seismic survey, on the contrary, is capable of high-precision imaging and, when augmented by drilling, etc., becomes capable of a more detailed interpretation, and that it also contributes effectively to the improvement of local disaster ...

1997-05-27

10

A new method of imaging particle tracks in solid state nuclear track detectors  

British Library Electronic Table of Contents (United Kingdom)

Summary Solid state nuclear track detectors are used to determine the concentration of a particles in the environment. The standard method for assessing exposed detectors involves 2D image analysis. However 3D imaging has the potential to provide additional information relating to angle as well as to differentiate clustered hit sequences and possibly energy of a particles but this could be time consuming. Here we describe a new method for rapid high-resolution 3D imaging of solid state nuclear track detectors. A `LEXT' OLS3100 confocal laser scanning microscope (Olympus Corporation, Tokyo, Japan) was used in confocal mode to successfully obtain 3D image data on four CR-39 plastic detectors. Three-dimensional visualization and image analysis enabled characterization of track features. This ...

2010-01-01

11

Focused ion beam assisted three-dimensional rock imaging at submicron scale  

Energy Technology Data Exchange (ETDEWEB)

Computation of effective flow properties of fluids in porous media based on three dimensional (3D) pore structure information has become more successful in the last few years, due to both improvements in the input data and the network models. Computed X-ray microtomography has been successful in 3D pore imaging at micron scale, which is adequate for many sandstones. For other rocks of economic interest, such as chalk and diatomite, submicron resolution is needed in order to resolve the 3D-pore structure. To achieve submicron resolution, a new method of sample serial sectioning and imaging using Focused Ion Beam (FIB) technology has been developed and 3D pore images of the pore system for diatomite and chalk have been obtained. FIB was used in the milling of layers as wide as 50 ...

2003-05-09

12

High-resolution magnetic resonance imaging: three-dimensional trabecular bone architecture and biomechanical properties.  

Science.gov (United States)

The purpose of this study was to use high-resolution magnetic resonance (MR) imaging combined with image analysis to investigate the three-dimensional (3D) trabecular structure, anisotropy, and connectivity of human vertebral, femoral, and calcaneal specimens. The goal was to determine whether: (a) MR-derived measures depict known skeletal-site-specific differences in architecture and orientation of trabeculae; (b) 3D architectural parameters combined with bone mineral density (BMD) improve the prediction of the elastic modulus using a fabric tensor formulation; (c) MR-derived 3D architectural parameters combined with BMD improve the prediction of strength using a multiple regression model, and whether these results corresponded to the results obtained using higher resolution depictions of trabecular architecture. A ...

1998-05-01

13

Comparison of Detector Intrinsic Spatial Resolution Characteristics for Sensor on the Entrance Surface and Conventional Readout Designs  

UK PubMed Central (United Kingdom)

We report on a high resolution, monolithic crystal PET detector design concept that provides depth of interaction (DOI) positioning within the crystal. Our design utilizes a novel sensor on...Full Text Available

2010-01-01

14

The effects of physical activity, education, and body mass index on the aging brain  

British Library Electronic Table of Contents (United Kingdom)

Abstract Normal human aging is accompanied by progressive brain tissue loss and cognitive decline; however, several factors are thought to influence brain aging. We applied tensor-based morphometry to high-resolution brain MRI scans to determine whether educational level or physical activity was associated with brain tissue volumes in the elderly, particularly in regions susceptible to age-related atrophy. We mapped the 3D profile of brain volume differences in 226 healthy elderly subjects (130F/96M; 77.9 3.6 SD years) from the Cardiovascular Health Study-Cognition Study. Statistical maps revealed the 3D profile of brain regions whose volumes were associated with educational level and physical activity (based on leisure-time energy expenditure). After controlling for age, sex, and physical...

2011-01-01

15

Reconstructions of archaeological contexts in OpenGl environments; Intelligenza artificiale per i beni culturali e le biblioteche digitali. Atti del Workshop  

Energy Technology Data Exchange (ETDEWEB)

DVR project concerns the creation of a virtual reality OpenGL system for desktop applications in archaeology. The main goal is the creation of a 3D information system using the real time interaction of OpenGL environments. The first case study implemented is the Vettii House, one of the most important and outstanding monuments in Pompei. The virtual reconstruction of these architectural models is based on very detailed photogrammetric surveys and it is connected with information layers and archaeometric data-bases regarding the state of conservation of walls, structures and any type of materials of the monument. A full 3D interface characterizes the system, comprising a high resolution texturing with detailed volumetric and geometric data. Finally, for the future, the project plans to fit the system for scientific and end users through the installation of stations on site.

2001-07-01

16

Quantitative analysis of X-Ray Microtomography images of metal powders in the course of sintering  

Energy Technology Data Exchange (ETDEWEB)

In situ X-Ray microtomography offers new opportunities for analysing sintering mechanisms since it allows 3D observation of the microstructural evolution of the powder all along a sintering cycle. With synchrotron radiation at ESRF, a 3D image with a resolution of 2 {mu}m can be obtained in about one minute. In addition to the visual examination of the images, relevant microstructural parameters can be measured through quantitative image analysis using recently developed tools. In this paper the results obtained with two materials, loose copper powder and compacted steel powder, are resumed. For copper powder, the dispersion of local parameters such as particle co-ordination number and porosity is investigated. Concerning steel compacts, data about pore morphology evolution and on local strains provides clues for understanding the anisotropic shrinkage of such compacts. (authors)

2005-07-01

17

A non-uniformly sampled 4D HCC(CO)NH-TOCSY experiment processed using maximum entropy for rapid protein sidechain assignment  

Science.gov (United States)

One of the stiffest challenges in structural studies of proteins using NMR is the assignment of sidechain resonances. Typically, a panel of lengthy 3D experiments are acquired in order to establish connectivities and resolve ambiguities due to overlap. We demonstrate that these experiments can be replaced by a single 4D experiment that is time-efficient, yields excellent resolution, and captures unique carbon-proton connectivity information. The approach is made practical by the use of non-uniform sampling in the three indirect time dimensions and maximum entropy reconstruction of the corresponding 3D frequency spectrum. This 4D method will facilitate automated resonance assignment procedures and it should be particularly beneficial for increasing throughput in NMR-based structural genomics initiatives.

2010-05-01

18

Comprehensive simulations of superhumps  

CERN Document Server

(Abridged) We use 3D SPH calculations with higher resolution, as well as with more realistic viscosity and sound-speed prescriptions than previous work to examine the eccentric instability which underlies the superhump phenomenon in semi-detached binaries. We illustrate the importance of the two-armed spiral mode in the generation of superhumps. Differential motions in the fluid disc cause converging flows which lead to strong spiral shocks once each superhump cycle. The dissipation associated with these shocks powers the superhump. We compare 2D and 3D results, and conclude that 3D simulations are necessary to faithfully simulate the disc dynamics. We ran our simulations for unprecedented durations, so that an eccentric equilibrium is established except at high mass ratios where the growth rate of the instability is very low. Our improved ...

2007-01-01

19

Synthesis of [3,3-D[sub 2  

Energy Technology Data Exchange (ETDEWEB)

The synthesis of [3, 3-D[sub 2

1993-01-01

20

Resolution enhancement by subtraction of confocal signals taken at different pinhole sizes.  

Science.gov (United States)

Subtractive imaging in confocal fluorescence light microscopy is based on the subtraction of a suitably weighted widefield image from a confocal image. An approximation to a widefield image can be obtained by detection with an opened confocal pinhole. The subtraction of images enhances the resolution in-plane as well as along the optic axis. Due to the linearity of the approach, the effect of subtractive imaging in Fourier-space corresponds to a reduction of low spatial frequency contributions leading to a relative enhancement of the high frequencies. Along the direction of the optic axis this also results in an improved sectioning. Image processing can achieve a similar effect. However, a 3D volume dataset must be acquired and processed, yielding a result essentially identical to subtractive imaging but superior in signal-to-noise ratio. The latter can be increased further with the technique of weighted averaging in ...

2003-01-01

21

Results from the photoemission spectroscopy beamline 2B1 at Pohang Light Source  

Energy Technology Data Exchange (ETDEWEB)

The results of photoemission spectroscopy using molybdenum and tantalum samples have been obtained from the new beamline 2B1 at Pohang Light Source. Beamline 2B1 is based on a spherical grating monochromator (SGM) which is equipped with five gratings. The photon energy range from 184 to 1100 eV was covered in this work using two gratings (Gratings 4 and 5). The photon energy resolution has been deduced from Ta Fermi-level spectra and 3d spectra of Mo.

1999-06-01

22

New MR techniques in diagnostic imaging of joints; Neue MRT-Techniken in der Gelenkdiagnostik  

Energy Technology Data Exchange (ETDEWEB)

Already, MR Imaging is superior in diagnostic imaging of joints in many cases; however, there have been recent developments, which are the subjects of this paper. With gradient-echo sequences acquired in 3D technique, it is possible to produce high-resolution images of joints in acceptable scantime, because gradient-echo sequences are less time-consuming than convential SE sequences. With the acquisition of two echoes, phase difference between water and fat protons have to be considered. 3D Imaging is capable of displaying complex pathology in a superior way, which should be useful in preoperative planning. Tissue contrast is altered by fat saturation or magnetization transfer in order to achieve better conspicuity of lesions. Although diagnostic value of some of these options is not yet clear and further clinical studies are needed, they are a promising possibility for improving MR ...

1993-12-31

23

Imaging of reflection seismic and radar wavefields: Monitoring of steam-heated oil reservoirs and characterization of nuclear waste repositories  

Energy Technology Data Exchange (ETDEWEB)

A new three-dimensional (3D) acoustic modelling method was developed using a first-order hyperbolic wave system which was solved with explicit finite dfferences. The numerical solution of the 3D wave system provides a useful method for simulating evolution of a pressure field corresponding to compressional type waves. Existing two-dimensional (2D) elastic modelling algorithms were modified and fine-tuned for computationally efficient and realistic wave propagation simulations in complex structures. An original formulation of the 3D reverse time migration method was developed which is very accurate, does not suffer from unwanted evenescent energy, can image dips beyond 90{degree}, and does not generate multiple energy. Two case studies were performed that involved steam stimulation projects in the Cold Lake deposit. Simulations were performed during different ...

1994-12-31

24

3D MRI of the colon: methods and first results of 5 patients; 3D-MRT des Kolons: Methodik und erste Ergebnisse  

Energy Technology Data Exchange (ETDEWEB)

Purpose: `Exoscopic` and endoscopic identification of colorectal pathologies via MRI. Methods: 5 patients (36-88 years), two normal and three with different colorectal pathologies (diverticular disease, polyps and carcinoma of the colon), were examined by MRI after colonoscopy. Subsequent to filling of the colon with a gadolinium-water mixture under MRI-monitoring, 3D-data sets of the colon were acquired in prone and supine positions over a 28 sec breathold interval. Subsequently multiplanar T{sub 1}-weighted 2D-sequences were acquired before and following i.v. administration of Gd-DTPA (0.1 mmol/kg BW). All imaging was performed in the coronal orientation. The 3D-data were interactively analysed based on various displays: Maximum intensity projection (MIP), surface shadowed display (SSD), multiplanar reconstruction (MPR), virtual colonoscopy (VC). Results: All of the colorectal ...

1997-09-01

25

Conformal radiation therapy: technical requirements and clinical applications  

International Nuclear Information System (INIS)

Conformal radiation therapy represents a considerable and attractive challenge in oncology. Its aim is mainly to improve local control by increasing the dose with an acceptable rate of complications. This work overviews the world literature on this subject. The technical and theoretical requirements are highlighted. These requirements include a precise definition of the target volume by digital imaging (essentially CT scan), but also clear view of the target volume and the organs at risk, a specific collimation of the beam, 3-D dose calculations, optimization procedures, and a rigid immobilization of the patient with verification of his position. Moreover, the clinical applications of conformal radiation therapy are reviewed and discussed. (authors). 80 refs., 1 tab.

1995-01-01

26

Numerical ray tracing of electrons in different 3D fringing fields of spherical deflectors  

Science.gov (United States)

This paper presents the results of numerical investigations on electron trajectories in different 3D fringing fields of spherical defectors. We start with a chosen set of geometrical values for the electrodes such as radius of curvature, electrode gap, angle between entrance and exit face. We do a first numerical calculation of the spatial potential distribution using a 3D electron optics program based on the finite difference method (FDM). Ray tracing through this potential distribution is then performed using another program, which also gives the potential and the electric field strength along the curved beam path. In the next step we estimate the position and the geometry of the field clamp using Herzog's formulae assuming the entrance of a parallel plate condenser to be a good approximation for the entrance of the spherical deflector in first order. For the consecutive numerical ...

1999-11-01

27

Developments of heavy-ion gas detectors at LNL  

Energy Technology Data Exchange (ETDEWEB)

The most important developments in gaseous detectors at LNL are reviewed. Some aspects of timing, pulse height and position resolutions of avalanche counters are reported. The experimental work on heavy-ion identification by Bragg curve spectroscopy is summarized.

1984-05-01

28

Surface Topography of 'Hotspot' Regions from a Single Cell SRF Cavity  

Energy Technology Data Exchange (ETDEWEB)

Performance of SRF cavities are limited by non-linear localized effects. The variation of local material characters between "hot" and "cold" spots is thus of intense interest. Such locations were identified in a BCP-etched large-grain single-cell cavity and removed for examination by high resolution electron microscopy (SEM), electron-back scattering diffraction microscopy (EBSD), optical microscopy, and 3D profilometry. Pits with clearly discernable crystal facets were observed in both "hotspot" and "coldspot" specimens. The pits were found in-grain, at bi-crystal boundaries, and on tri-crystal junctions. They are interpreted as etch pits induced by surface crystal defects (e.g. dislocations). All "coldspots" examined had qualitatively low density of etching pits or very shallow tri-crystal boundary junction. EBSD revealed the crystal structure surrounding the pits via crystal phase orientation mapping, while ...

2009-05-01

29

Sunyaev-Zeldovich profiles for clusters and groups of galaxies  

CERN Document Server

The Sunyaev-Zeldovich (SZ) effect gives a measure of the thermal energy and electron pressure in groups and clusters of galaxies. In the near future SZ surveys will map hundreds of systems, shedding light on the pressure distribution in the systems. The thermal energy is related to the total mass of a system of galaxies, but it is only a projection that is observed through the SZ effect. A model for the 3D distribution of pressure is needed to link the SZ signal to the total mass of the system. In this work we construct an empirical model for the 2D and 3D SZ profile, and compare it to a set of realistic high resolution SPH simulations of galaxy clusters and groups, and to a stacked SZ profile for massive clusters derived from WMAP data. Furthermore, we combine observed temperature profiles with dark matter potentials to yield an additional constraint, under the assumption of ...

2007-01-01

30

Alloying effect on K to L shell vacancy transfer probabilities in 3d transition metals  

British Library Electronic Table of Contents (United Kingdom)

The alloying effects on K to L shell vacancy transfer probabilities (?KL) in 3d transition metals have been carried out by X-ray fluorescence studies of various alloy compositions. K X-ray intensity ratios of Ti, Cr, Fe, Co, Ni, and Cu elements in the FexNi1?x, FexCr1?x, NixCr1?x, FexCryNi1?(x+y), TixNi1?x, TixCo1?x, and CoxCu1?x alloys have been measured following excitation by 22.69keV X-rays from a 10 mCi 109Cd radioactive point source and ?KL values for alloying elements have been determined from these ratios. The spectrum of characteristic K-X-ray photons from samples were detected with a high resolution Si(Li) detector coupled to a 4 K multichannel analyzer. The present investigation makes it possible to ...

2010-01-01

31

New focal plane detector system for the broad range spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A focal plane detector system consisting of a vertical drift chamber, parallel plate avalanche counters, and an ionization chamber with segmented anodes has been installed in the Broad Range Spectrometer at the Holifield Facility at Oak Ridge. The system, which has been designed for use with light-heavy ions with energies ranging from 10 to 25 MeV/amu, has a position resolution of approx. 0.1 mm, a scattering angle resolution of approx. 3 mrad, and a mass resolution of approx. 1/60.

1984-01-01

32

On the calculation of scattered fields by 3-D structure in the time-domain electromagnetic (TDEM) method; Jikan ryoiki denjiho ni okeru sanjigen kozo kara no sanranba no keisan ni tsuite  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the calculation method of 3-D underground structures in TDME method which measures only field components. Recently, FDTD method was developed as calculation method in time domain difference calculus, and the forward analysis accuracy of 3-D fields was rapidly improved. The survey results using a large-scale loop (600m{times}360m) were numerically analyzed by FDTD method. 16 measuring lines were prepared in both X and Y directions, and measuring points were prepared on intersection points of the measuring lines. Since signal current is staircase one, step and impulse responses of the ground were determined by calculating magnetic field and its time differentiation. The rectangular body (120m{times}120m{times}100m) of 0.2S/m in conductivity (5 ohm m in resistivity) was installed 160m under the ground as 3-D resistivity anomaly. The ground of ...

1996-10-01

33

Horizontal Steam Generator Thermal-Hydraulics at Various Steady-State Power Levels  

Science.gov (United States)

Three-dimensional computer simulation and analyses of the horizontal steam generator thermal-hydraulics of the WWER 1000 nuclear power plant have been performed for 50% and 75% partial loads, 100% nominal load and 110% over-load. Presented results show water and steam mass flow rate vectors, steam void fraction spatial distribution, recirculation zones, swell level position, water mass inventory on the shell side, and other important thermal-hydraulic parameters. The simulations have been performed with the computer code 3D ANA, based on the 'two-fluid' model approach. Steam-water interface transport processes, as well as tube bundle flow resistance, energy transfer, and steam generation within tube bundles are modelled with {sup c}losure laws{sup .} Applied approach implies non-equilibrium thermal and flow conditions. The model is solved by the control volume procedure, which has been extended in order to ...

2002-07-01

34

Horizontal Steam Generator Thermal-Hydraulics at Various Steady-State Power Levels  

International Nuclear Information System (INIS)

Three-dimensional computer simulation and analyses of the horizontal steam generator thermal-hydraulics of the WWER 1000 nuclear power plant have been performed for 50% and 75% partial loads, 100% nominal load and 110% over-load. Presented results show water and steam mass flow rate vectors, steam void fraction spatial distribution, recirculation zones, swell level position, water mass inventory on the shell side, and other important thermal-hydraulic parameters. The simulations have been performed with the computer code 3D ANA, based on the 'two-fluid' model approach. Steam-water interface transport processes, as well as tube bundle flow resistance, energy transfer, and steam generation within tube bundles are modelled with "closure laws". Applied approach implies non-equilibrium thermal and flow conditions. The model is solved by the control volume procedure, which has been extended in order to take into account the ...

2002-04-14

35

Reduced resolution polarimetric imagery characterization of the 1990 Galveston Bay oil spill  

Energy Technology Data Exchange (ETDEWEB)

Low resolution visual polarimetric photographic imagery of the Galveston Bay oil spill from a tanker accident on July 28, 1990 was obtained and analyzed. The low resolution imagery (30 to 100 meters) was obtained concurrently with high resolution (1 meter), and is representative of what would be seen by a polarimetric satellite. Orthogonal red-green-blue (RGB) polarimetric images obtained with color photography were digitized by KODALUX on to a CD ROM. These polarimetric images were then used to calculate the percent polarization. The positive and negative percent polarized radiation scattered by each of the sea surface waves is seen individually in high resolution imagery. (Percent polarization is defined as positive when the dominant radiation is perpendicular to the plane of incidence and negative when it is parallel). The analysis of low ...

1997-06-01

36

Segmented focal plane detector for light and heavy ions  

Energy Technology Data Exchange (ETDEWEB)

A segmented focal plane detector for an Enge split-pole spectrograph has been developed for the study of breakup reactions at very low relative energies. It consists of a 61 cm long segmented position-sensitive parallel plate avalanche counter backed by a large Bragg curve detector. A segmented plastic scintillator is mounted behind the anode of the Bragg curve detector and is used for particle identification of low-ionizing particles. The dead space between the two sections of the focal plane detector is 2.5 mm. The intrinsic position resolution of the detector is 1 mm. The intrinsic energy resolution depends on the energy of the incident ion and can be as good as 0.55%. The nuclear charge and mass resolutions are 0.3 e and 0.3 u, respectively. (orig.).

1992-06-15

37

Quadrant anode image sensor  

Science.gov (United States)

A position-sensitive event-counting electronic readout system for microchannel plates (MCPs) is described that offers the advantages of high spatial resolution and fast time resolution. The technique relies upon a four-quadrant electron-collecting anode located behind the output face of the microchannel plate, so that the electron cloud from each detected event is partly intercepted by each of the four quadrants. The relative amounts of charge collected by each quadrant depend on event position, permitting each event to be localized with two ratio circuits. A prototype quadrant anode system for ion, electron, and extreme ultraviolet imaging is described. The spatial resolution achieved, approx. =10 ..mu.., allows individual MCP channels to be distinguished. (AIP)

1976-11-01

38

Quadrant anode image sensor  

International Nuclear Information System (INIS)

A position-sensitive event-counting electronic readout system for microchannel plates (MCPs) is described that offers the advantages of high spatial resolution and fast time resolution. The technique relies upon a four-quadrant electron-collecting anode located behind the output face of the microchannel plate, so that the electron cloud from each detected event is partly intercepted by each of the four quadrants. The relative amounts of charge collected by each quadrant depend on event position, permitting each event to be localized with two ratio circuits. A prototype quadrant anode system for ion, electron, and extreme ultraviolet imaging is described. The spatial resolution achieved, approx. =10 #mu#, allows individual MCP channels to be distinguished.

9472-01-01

39

DNA damage intensity in fibroblasts in a 3-dimensional collagen matrix correlates with the Bragg curve energy distribution of a high LET particle  

International Nuclear Information System (INIS)

The DNA double-strand break (DSB) damage response induced by high energy charged particles on lung fibroblast cells embedded in a 3-dimensional (3-D) collagen tissue equivalents was investigated using antibodies to the DNA damage response proteins gamma-histone 2AX (#gamma#-H2AX) and phosphorylated DNA-PKcs (p-DNA-PKcs). 3-D tissue equivalents were irradiated in positions across the linear distribution of the Bragg curve profiles of 307.7 MeV/nucleon, 556.9 MeV/nucleon, or 967.0 MeV/nucleon "5"6Fe ions at a dose of 0.30 Gy. Patterns of discrete DNA damage streaks across nuclei or saturated nuclear damage were observed, with saturated nuclear damage being more predominant as samples were positioned closer to the physical Bragg peak. Quantification of the DNA damage signal intensities at each distance for each of the examined energies revealed a biological Bragg ...

2010-03-01

40

Trabecular scaffolds created using micro CT guided fused deposition modeling  

British Library Electronic Table of Contents (United Kingdom)

Free form fabrication and high resolution imaging techniques enable the creation of biomimetic tissue engineering scaffolds. A 3D CAD model of canine trabecular bone was produced via micro CT and exported to a fused deposition modeler, to produce polybutylene terephthalate (PBT) trabeculated scaffolds and four other scaffold groups of varying pore structures. The five scaffold groups were divided into subgroups (n=6) and compression tested at two load rates (49?N/s and 294?N/s). Two groups were soaked in a 25??C saline solution for 7?days before compression testing. Micro CT was used to compare porosity, connectivity density, and trabecular separation of each scaffold type to a canine trabecular bone sample. At 49?N/s the dry trabecular scaffolds had a compressive stiffness of 4.94?1.19?MP...

2008-01-01

41

An imaging. gamma. -ray detector with scatter rejection for beam position control in radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

An imaging detector for {gamma}-rays ({approx equal}1 MeV) based on minicell MWPCs with converters and a position resolution of {Delta}x=0.5 mm has been developed and tested. Very high rate capability (>10{sup 8}/cm{sup 2} s) and a special readout for suppression of scattered radiation are implemented allowing to enhance the measured contrast. The relevant physical processes are discussed and first pictures are presented. (orig.).

1991-12-01

42

A photon beam position monitor for SSRL beamline 9  

Energy Technology Data Exchange (ETDEWEB)

We present here the concept of a simple one dimensional photon beam position monitor for use with high power synchrotron radiation beams. It has micron resolution, reasonable linearity in an inexpensive design. Most important, is its insensitivity to diffusely scattered low energy radiation from components upstream of the monitor.

1995-10-01

43

Development of nanometer resolution C-Band radio frequency beam position monitors in the Final Focus Test Beam  

Energy Technology Data Exchange (ETDEWEB)

Using a 47 GeV electron beam, the Final Focus Test Beam (FFTB) produces vertical spot sizes around 70 nm. These small beam sizes introduce an excellent opportunity to develop and test high resolution Radio Frequency Beam Position Monitors (RF-BPMs). These BPMs are designed to measure pulse to pulse beam motion (jitter) at a theoretical resolution of approximately 1 nm. The beam induces a TM{sub 110} mode with an amplitude linearly proportional to its charge and displacement from the BPM's (cylindrical cavity) axis. The C-band (5,712 MHz) TM{sub 110} signal is processed and converted into beam position for use by the Stanford Linear Collider (SLC) control system. Presented are the experimental procedures, acquisition, and analysis of data demonstrating resolution of jitter near 25 nm. With the design of future e{sup +}e{sup -} linear colliders requiring spot sizes close to 3 ...

1998-08-01

44

New real-time MR image-guided surgical robotic system for minimally invasive precision surgery  

Energy Technology Data Exchange (ETDEWEB)

To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using robotic forceps. The position of the probe was monitored ...

2008-04-15

45

A computer-assisted method for 3D subtraction angiography based on spiral CT  

International Nuclear Information System (INIS)

The objective of this study was to develop a method for 3D subtraction CT angiography and to optimize the visualization after semiautomatic segmentation. Ten patients with aneurysms of the abdominal aorta were examined using spiral CT. To reconstruct the vessels, as well as adjacent organs such as the liver and kidneys, one image data volume was acquired before and after injection of the contrast agent. The CT scans were obtained with a Siemens Somatom Plus 4. To improve the results of automatic segmentation, as well as visualization by maximum intensity projection (i.e. removal of bony structures), subtraction of both image volumes is necessary. However, small translation shifts disturb the subtraction process and produce artificial contours. To calculate the disparities along the three coordinate axes of two corresponding image volumes, a cepstrum filter is applied to a pair of image volumes. After detection of the disparities, which manifest ...

46

Reservoir anatomy within a sequence stratigraphic framework: The Pennsylvanian Breathitt group of Eastern Kentucky  

Energy Technology Data Exchange (ETDEWEB)

Detailed quantitative sequence stratigraphic analysis and three-dimensional (3-D) modeling of the fluvio-deltaic Pikeville, Hyden, and four Corners formations of the Breathitt Group, eastern Kentucky, indicate that it is possible to make confident deterministic correlations of sand bodies at offshore development well spacings. The key to high-confidence correlation is the delineation of the 3-D architecture of third-order composite sequences, which are seismically mappable, and the recognition of internal fourth-order sequences, which are stacked into lowstand, transgressive, and highstand sequence sets. Volumetric partitioning of reservoir sand bodies between systems tracts and sequences allows prediction of channel sandstone geometries and channel: crevasse splay ratios. Furthermore, channel-fill type is predictable from the sequence stratigraphy. Within 13 studied fourth-order sequences, incised ...

1993-09-01

47

MULTICOMPONENT SEISMIC ANALYSIS AND CALIBRATION TO IMPROVE RECOVERY FROM ALGAL MOUNDS: APPLICATION TO THE ROADRUNNER/TOWAOC AREA OF THE PARADOX BASIN, UTE MOUNTAIN UTE RESERVATION, COLORADO  

Energy Technology Data Exchange (ETDEWEB)

This report describes the results made in fulfillment of contract DE-FG26-02NT15451, ''Multicomponent Seismic Analysis and Calibration to Improve Recovery from Algal Mounds: Application to the Roadrunner/Towaoc Area of the Paradox Basin, Ute Mountain Ute Reservation, Colorado''. Optimizing development of highly heterogeneous reservoirs where porosity and permeability vary in unpredictable ways due to facies variations can be challenging. An important example of this is in the algal mounds of the Lower and Upper Ismay reservoirs of the Paradox Basin in Utah and Colorado. It is nearly impossible to develop a forward predictive model to delineate regions of better reservoir development, and so enhanced recovery processes must be selected and designed based upon data that can quantitatively or qualitatively distinguish regions of good or bad reservoir permeability and porosity between existing well control. Recent advances in seismic acquisition and ...

2003-07-10

48

4D experience on Girassol Field block 17, Angola  

Energy Technology Data Exchange (ETDEWEB)

The Girassol field is located in Angolan deep water of Block 17 and consists of large vertically stacked turbidities complexes. The reservoir extends over approximately 200 km{sup 2} and water depth ranges between 1300 and 1400 meters. In that context High Resolution 3D seismic became the most valuable tool to describe and monitor the reservoir. The field development plan took into account, through re-injection of the gas into the reservoir, Total environmental policy imposing the recycling of production gas. Monitoring of this injection was the main reason to shoot the first High Resolution 4D extremely early in the life of field. Despite the complexity of interpretation due to complex fluid situation and pressure effect, the results went way beyond expectations as the 4D images are of very high quality. Data has also been used to update and refine the reservoir flow model as well as to help deciding ...

2004-07-01

49

CHAPLET-3D results for the 3-D extension C5G7 Mox benchmarks  

Energy Technology Data Exchange (ETDEWEB)

The 3-dimensional (3D) extension C5G7 MOX benchmark problems were solved by CHAPLET-3D code which is based on the idea of dynamic linkage of the multi-plane method of characteristics solutions. The benchmark results are quite accurate in comparison with the reference solutions, independently of the axial solver incorporated in the CHAPLET-3D code. (author)

2005-07-01

50

Sequential stratigraphy and probabilistic modeling of reservoirs from a deep sea fan (Namorado field, Brazil). Integration of geological and geophysical data; Stratigraphie sequentielle et modelisation probabiliste des reservoirs d`un cone sous-marin profond (champ de Namorado, Bresil). Integration des donnees geologiques et geophysiques  

Energy Technology Data Exchange (ETDEWEB)

The main objective of this dissertation is to build a numerical 3D geological model of a turbidite reservoir using well and seismic data. For the, the first step was to elaborate a depositional model using a high-resolution genetic stratigraphy approach. Simultaneously, the stratigraphic inversion over the seismic data resulted in an optimal acoustic impedance model. Both models, were used to build, by geostatistical methods, a 3-D geological model, which represents the spatial distribution of the reservoir facies. The studied case is the late Cretaceous Namorado turbidite system in the Campos basin, which is the reservoir of the Namorado oil field, located 80 km from the Brazilian coast, under a bathymetry between 110 and 250 m. The reservoir is a turbidite succession with 90 to 180 m thickness. It is composed by sand-supported conglomerates, matrix-supported conglomerate, massive ...

1997-01-29

51

Electrophysiological Study and Catheter Ablation with 3D Mapping  

Medline Plus

... see and electrophysiological study and catheter ablation with 3D mapping. During the procedure, doctors look at the ... perform a electrophysiology study with ablation, using our 3D mapping system. Keep in mind, that during the ...

52

Semiconductor-metal transition of pyrite FeS_2 under high pressure by full-potential linearized-augmented plane wave calculations  

International Nuclear Information System (INIS)

The effects of hydrostatic pressure on the electronic band structure of the semiconductor mineral iron pyrite FeS_2 have been investigated theoretically by an ab initio full-potential linearized-augmented plane wave (FPLAPW) method within a local approximation (LDA/GGA) to the density functional theory. The calculations predict that at a pressure of 94.1 GPa the indirect band gap of pyrite FeS_2 vanishes and the material becomes a metal. This is due to the presence of the S-S and Fe-S bonds, which provide novel energy band distortions in the process of attaining the metallic state. Analysis indicates that, under increasing high pressure, the conduction bands (3p_z of sulfur and 3d_x_"2_-_y_"2+3d_x_y of iron) intrude downwards into the valence bands, which are predominantly 3d in nature. At normal pressure, the lattice constant, the bulk modulus, sulfur ...

2006-10-11

53

Initiation of conformal radiotherapy with a multileaf-collimator - An approach to clinical routine  

International Nuclear Information System (INIS)

The implementation of a three-dimensional conformal radiotherapy facility in the radiotherapy department of the Heinrich Heine University is described. Complex radiotherapy techniques with commercially available networked systems are introduced to improve clinical work. Over 18 month we have gained clinical experience with a PHILIPS Multileaf Collimator (MLC) mounted on a SL 25 linear accelerator. For a limited period the MLC was used as a conventional blocking device. The standard MLC-shapes are controlled with a stand-alone computer system. In addition, a three-dimensional treatment planning system (3-D-TPS / TMS-Radix, Helax AB) based on convolution/superposition algorithms was recently installed. Treatment optimization is achieved using static field arrangements with complete volumetric computerized tomographic patient data for 3-D-TPS. Conformal adaptation of the 95%-isodose to the Planning Target ...

1995-10-01

54

Three-dimensional, three-component wall-PIV  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a new time-resolved three-dimensional, three-component (3D-3C) measurement technique called wall-PIV. It was developed to assess near wall flow fields and shear rates near non-planar surfaces. The method is based on light absorption according to Beer-Lambert's law. The fluid containing a molecular dye and seeded with buoyant particles is illuminated by a monochromatic, diffuse light. Due to the dye, the depth of view is limited to the near wall layer. The three-dimensional particle positions can be reconstructed by the intensities of the particle's projection on an image sensor. The flow estimation is performed by a new algorithm, based on learned particle trajectories. Possible sources of measurement errors related to the wall-PIV technique are analyzed. The accuracy analysis was based on single particle experiments and a three-dimensional artificial data set simulating a rotating ...

2010-06-15

55

PDBpaint, a visualization webservice to tag protein structures with sequence annotations  

British Library Electronic Table of Contents (United Kingdom)

Summary: Protein features are often displayed along the linear sequence of amino acids that make up that protein, but in reality these features occupy a position in the folded proteins 3D space. Mapping sequence features to known or predicted protein structures is useful when trying to deduce the function of those features and when evaluating sequence or structural predictions. To facilitate this goal, we developed PDBpaint, a simple tool that displays protein sequence features gathered from bioinformatics resources on top of protein structures, which are displayed in an interactive window (using the Jmol Java viewer). PDBpaint can be used either with existing protein structures or with novel structures provided by the user. The current version of PDBpaint allows the visualization of annot...

2011-01-01

56

Application research on three-dimensional virtual mine in the framework of internet of things  

British Library Electronic Table of Contents (United Kingdom)

Based on the information system characteristics of mine, proposed network architecture design of the mine property. And in this framework based on the design of three-dimensional virtual mine described the application of intelligent management platform. Three-dimensional virtual underground mine that shows the situation, the core application is through remote monitoring system of information exchange between devices (material object communication). Internet of things in the framework of mining three-dimensional virtual reconstruction of mine. On coal mine safety in the production process of human, machine and environment, control elements and their harmony and unity. 3D virtual mine management platform integrates personnel positioning, dust control, gas monitoring, roof pressure monitoring...

2011-01-01

57

Position sensitive and Bragg curve spectroscopy detector system  

Energy Technology Data Exchange (ETDEWEB)

A heavy ion gas detector system consisting of a Bragg-curve spectroscopy ionization chamber for particle identification and a multiwire proportional chamber as position sensitive fast trigger device is described. The Bragg IC has been tested with several beams up to Z=36 to investigate some aspects of the BCS method. Results are reported on energy resolution and linearity, Z resolving power and mass sensitivity. The energy resolution is well below 1%. The Bragg-peak amplitude is fairly independent of the energy in a wide energy range and single elements are identified up to Z=38 with a resolving power Z/..delta..Zproportional50-80. Isotope identification by range measurement is limited by the straggling in the ionization process and the mass resolving power is M/..delta..Mproportional20-26 for S and Si isotopes. The MWPC allows subnanosecond time resolution and position ...

1984-08-01

58

Position sensitive and Bragg curve spectroscopy detector system  

International Nuclear Information System (INIS)

A heavy ion gas detector system consisting of a Bragg-curve spectroscopy ionization chamber for particle identification and a multiwire proportional chamber as position sensitive fast trigger device is described. The Bragg IC has been tested with several beams up to Z=36 to investigate some aspects of the BCS method. Results are reported on energy resolution and linearity, Z resolving power and mass sensitivity. The energy resolution is well below 1%. The Bragg-peak amplitude is fairly independent of the energy in a wide energy range and single elements are identified up to Z=38 with a resolving power Z/#DELTA#Zproportional50-80. Isotope identification by range measurement is limited by the straggling in the ionization process and the mass resolving power is M/#DELTA#Mproportional20-26 for S and Si isotopes. The MWPC allows subnanosecond time resolution and position identification ...

59

Focal plane detector for reactions with medium weight projectiles  

Energy Technology Data Exchange (ETDEWEB)

A new focal plane detector for an Enge split pole spectrograph has been developed which is able to resolve individual elements and isotopes up to the mass 100 region. It consists of a 60 cm long position sensitive parallel plate avalanche counter backed by a large Bragg curve detector. Compared with other position sensitive focal plane counters the new detector system has a very good time resolution (less than 300 ps) and can be operated at much higher counting rates (up to 25 kHz). The intrinsic resolution of the position detector is less than 1 mm. In addition to the energy and the nuclear charge signal obtained from the Bragg curve detector the angle of incidence into the detector can be measured with an accuracy of better than 1/sup 0/. The detector has already been used in a variety of experiments where good timing, counting rate behavior, and excellent mass ...

1988-12-01

60

Repair of a Complex Congenital Cardiac Defect  

Medline Plus

... stenosis. It looks from the transesophageal and the 3-D echo that most of the problem is really ... posterior leaflet, which you can see on the 3-D echo image is a major source. The anterior ...

62

GPS and Google Earth based 3D assisted driving system for trucks in surface mines  

British Library Electronic Table of Contents (United Kingdom)

In order to reduce the number of surface mining accidents related to low visibility conditions and blind spots of trucks and to provide 3D information for truck drivers and real time monitored truck information for the remote dispatcher, a 3D assisted driving system (3D-ADS) based on the GPS, mesh-wireless networks and the Google-Earth engine as the graphic interface and mine-mapping server, was developed at Virginia Tech. The research results indicate that this 3D-ADS system has the potential to increase reliability and reduce uncertainty in open pit mining operations by customizing the local 3D digital mining map, constructing 3D truck models, tracking vehicles in real time using a 3D interface ...

2010-01-01

63

Superconducting strip detectors as position sensitive particle detectors  

Energy Technology Data Exchange (ETDEWEB)

The feasibility of using of current-biased superconducting strips for radiation detection is investigated. Narrow Ta strips are exposed to 5.5 MeV [alpha]-particle radiation and the rise-time of the induced voltage pulses is measured as function of temperature and bias current. The rise-time of the voltage signal strongly depends on the site on the strip which is hit by the [alpha]-particle. In order to determine the spatial resolution of a superconducting strip detector, position-sensitive measurements were performed. The maximum lateral resolution estimated so far is 25[mu]m in a 7[mu]m wide, 340 nm thick and 0.6 mm long Ta-strip. (orig.)

1994-02-01

64

Development of a new #gamma#-ray detector for PEM applications  

International Nuclear Information System (INIS)

The authors are developing a high specificity detector for detecting the increased metabolic rate of breast tumors. Positron emission mammography (PEM) provides a highly efficient, high spatial resolution positron imaging system. PMT plays a very important role in PEM detectors, because most of the systems consist of scintillator arrays coupled with PMT. Our detector is composed of 20 x 20 arrays of 2 mm x 2 mm x 20 mm of Bi_4Ge_3O_1_2 (BGO) scintillators and a novel flat panel position-sensitive PMT (FP-PS-PMT)-Hamamatsu R8400-00-M256. Spatial resolutions of 2.0 mm FWHW and energy resolutions of 23% FWHM are achieved. (authors)

2007-05-01

65

Use of microbes for paraffin cleanup at Naval Petroleum Reserve No. 3  

Energy Technology Data Exchange (ETDEWEB)

Naval Petroleum Reserve No. 3 (NPR-3), also known as Teapot Dome, is a government-owned oil field in Natrona County, Wyoming. It is an asymmetrical anticline located on the western edge of the Powder River Basin, just south of the Salt Creek Anticline. Production started in 1922, and today the field is a marginally economic stripper field with average production of less than 3 BOPD (0.5 m{sup 3}/D) per well. Total field production is about 1,800 BOPD (286 m{sup 3}/D). The Second Wall Creek Formation was waterflooded from 1979 until June 1992 with poor results due to the extensive natural fracture system in this sandstone unit. Since water injection ceased, reservoir pressure has declined to very low levels. Liquids extraction and reinjection of the gas produced from high-GOR wells along the gas-oil contact continues, but the average gas cap pressure has fallen to approximately 150 psi (1.03 MPa) from an ...

1995-12-31

66

TIME EVOLUTION OF CORONAL MAGNETIC HELICITY IN THE FLARING ACTIVE REGION NOAA 10930  

International Nuclear Information System (INIS)

To study the three-dimensional (3D) magnetic field topology and its long-term evolution associated with the X3.4 flare of 2006 December 13, we investigate the coronal relative magnetic helicity in the flaring active region (AR) NOAA 10930 during the time period of December 8-14. The coronal helicity is calculated based on the 3D nonlinear force-free magnetic fields reconstructed by the weighted optimization method of Wiegelmann, and is compared with the amount of helicity injected through the photospheric surface of the AR. The helicity injection is determined from the magnetic helicity flux density proposed by Pariat et al. using Solar and Heliospheric Observatory/Michelson Doppler Imager magnetograms. The major findings of this study are the following. (1) The time profile of the coronal helicity shows a good correlation with that of the helicity accumulation by injection through the surface. (2) The ...

2010-09-10

67

Photochromes for Optical Memory  

International Science & Technology Center (ISTC)

Photochromes for New Generation of Highly Efficient Computers with Three Dimensional (3D) Optical Memory

72

 

Medline Plus

... 2009) Arrhythmia Electrophysiological Study and Catheter Ablation with 3D Mapping (Mercy Hospital, Miami, FL, 11/15/2007) ...

73

Real time neutron diffraction experiments using Bragg edges  

Energy Technology Data Exchange (ETDEWEB)

Time resolved phase transition and strain experiments have been performed on the millisecond time scale using a Bragg-edge transmission technique that has been developed at the Los Alamos National Laboratory. The precision with which lattice parameters can be determined from edge positions is sufficient to perform high-resolution strain measurements in uniaxial stress.

1995-12-31

74

Real time neutron diffraction experiments using Bragg edges  

International Nuclear Information System (INIS)

Time resolved phase transition and strain experiments have been performed on the millisecond time scale using a Bragg-edge transmission technique that has been developed at the Los Alamos National Laboratory. The precision with which lattice parameters can be determined from edge positions is sufficient to perform high-resolution strain measurements in uniaxial stress.

1994-12-02

75

A large-acceptance Bragg curve spectrometer with a longitudinal electric field and a segmented anode  

Energy Technology Data Exchange (ETDEWEB)

A large-acceptance Bragg curve spectrometer with a longitudinal electron collection field and a segmented anode has been constructed and tested. The effects on the charge resolution of the entrance angle and entrance position of the incident particle have been studied. Simulations have been done in order to isolate the contribution to the overall detector performance of the signal-shaping electronics from that of the intrinsic design of the detector. ((orig.))

1994-07-15

76

High-resolution "1H magnetic resonance spectroscopy imaging at 1.5 and 3 Tesla of the human brain: development of techniques and applications for patients with primary brain tumors and multiple sclerosis  

International Nuclear Information System (INIS)

The aim of this work was to develop several strategies and software-packages for the evaluation of in-vivo-data of the human brain, which were acquired with high-resolution 1H-MRSI at 1.5 and 3 T. Several studies involving phantoms, volunteers and patients were performed. Quality assurance studies were conducted in order to evaluate the reproducibility of the applied MR-techniques at both field strengths. A qualitative comparison-study between MRSI-data from a 1.5 T clinical MR-scanner and a 3 T research MR-scanner showed the advantages of the more advanced MRSI sequences and higher field strength (3 T). A study involving patients with primary brain tumours (gliomas) was performed in cooperation with the Department of Neurosurgery (University of Erlangen-Nuremberg). The methods developed in the course of this study, such as the integration of MRS-data into a stereotactic-system, the segmentation of metabolic maps and the correlation with histopathological findings ...

77

Position sensitive detection of individual nuclear particle scintillations using image intensifier tubes  

International Nuclear Information System (INIS)

An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector system are presented in this paper. (orig.).

1996-01-01

78

Particle identification for heavy ions in a time-of-flight spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A time-of-flight (TOF) spectrometer has been constructed at the JAERI 20 MV tandem accelerator facility. A position-sensitive start detector, which consists of a thin carbon foil, microchannel plates and a resistive plate, was developed for the TOF measurements through the spectrometer. The time and position resolutions obtained were 120 ps and 0.3 mm for ..cap alpha.. particles from /sup 241/Am, respectively. A two-dimensional position-sensitive detector was also developed to measure the solid angle of the spectrometer and the maximum solid angle obtained was 9.5 msr. As a particle detector a Bragg curve ionization chamber was developed. From the Bragg curves of heavy ions in the detector, energies, ranges and Bragg curve peaks were measured and used for particle identification. The resolving power Z/..delta..Z of the atomic number was about 50.

1982-05-01

79

Ultrashort echo time MRI of cortical bone at 7 tesla field strength: A feasibility study  

British Library Electronic Table of Contents (United Kingdom)

AbstractPurpose: To implement and examine the feasibility of a three-dimensional (3D) ultrashort TE (UTE) sequence on a 7 Tesla (T) clinical MR scanner in comparison with 3T MRI at high isotropic resolution. Materials and Methods: Using an in-house built saddle coil at both field strengths we have imaged mid-diaphysial sections of five fresh cadaveric specimens of the distal tibia. An additional in vivo scan was performed at 7 Tesla using a quadrature knee coil. Results: Using the same type of saddle coil at both field strengths, a significant increase in SNR at 7T compared with 3T (factor 1.7) was found. Significantly shorter T2* values were found at the higher field strength (T2* = 552.2 126 s at 7T versus T2* = 1163 391 s at 3T). Conclusion: UHF MRI at 7T has great potential for imaging...

2011-01-01

80

Spectroscopy of "8"8Sr with the "8"7Sr(n,#gamma#) and "8"7Sr(d,p) reactions  

International Nuclear Information System (INIS)

The #gamma#-ray spectrum emitted after thermal neutron capture in "8"7Sr was studied at the ILL high flux reactor with pair- and intrinsic Ge-spectrometers. 661 transitions were assigned to the reaction "8"7Sr(n,#gamma#)"8"8Sr and 205 of them were placed into a "8"8Sr level scheme of 47 levels. This represents 88% of the observed intensity. The level energies were determined with a precision of better than 22 ppm; the neutron binding energy was determined as 11 112.69 (22) keV. To aid the analysis high resolution particle spectra of the reaction "8"7Sr(d,p)"8"8Sr were measured at 20 MeV deuteron energy with the Munich Q3D spectrometer. 85 states were observed with this reaction. The data helped to establish newly found levels and to differentiate between primary and secondary transitions in the (n,#gamma#) data. The observed level densities and primary transition strengths are compared with statistical model predictions and ...

81

K beta X-ray transition energies of M-shell-ionized ions of Ti through Ni in a plasma  

Energy Technology Data Exchange (ETDEWEB)

K beta X-ray lines from partially M-shell-ionized ions of titanium through nickel which are produced in vacuum-spark plasmas have been observed systematically for the first time, using a high-resolution curved-crystal spectrometer. Each K beta line is clearly separated into its corresponding charge state. As a result, it is possible to measure the K beta-type transition energies of the M-shell-ionized ions. The transition energies accurately determined are compared with those calculated for iron ions, and the agreement is excellent except for ions having some additional 3d outer-shell electrons or 3s inner-shell vacancies. The square root of the K beta transition frequency is expressed as a linear function of the nuclear charge for isoelectronic sequences. The effective nuclear charges have been also determined for each K beta transition. The 3p electrons do not affect the effective nuclear charges. 10 references.

1985-05-01

82

Correlations between the proton temperature anisotropy and Alfv\\'en-cyclotron waves in the solar wind  

CERN Document Server

Correlations are studied between the power density of Alfv\\'en-cyclotron waves (having frequencies between 0.02 and 2 Hz) and the ratio of the perpendicular and parallel temperature of the protons. The wave power spectrum is evaluated from high-resolution 3D magnetic field vector components, and the ion temperatures are derived from the velocity distribution functions as measured in fast solar wind during the Helios-2 primary mission at radial distances from the Sun between 0.3 AU and 0.9 AU. From our statistical analysis, we obtain a striking correlation between the increases in the proton temperature ratio and enhancements in the wave power spectrum. Near the Sun the transverse part of the wave power is often found to be by more than an order of magnitude higher than its longitudinal counterpart. Also the measured ion temperature anisotropy appears to be limited by the theoretical threshold value for the ion-cyclotron ...

2010-01-01

83

Noise bias in the refinement of structures derived from single particles  

Energy Technology Data Exchange (ETDEWEB)

One of the main goals in the determination of three-dimensional macromolecular structures from electron microscope images of individual molecules and complexes (single particles) is a sufficiently high spatial resolution, about 4 A, at which the interpretation with an atomic model becomes possible. To reach high resolution, an iterative refinement procedure using an expectation maximization algorithm is often used that leads to a more accurate alignment of the positional and orientational parameters for each particle. We show here the results of refinement algorithms that use a phase residual, a linear correlation coefficient, or a weighted correlation coefficient to align individual particles. The algorithms were applied to computer-generated data sets that contained projections from model structures, as well as noise. The algorithms show different degrees of over-fitting, especially at high resolution ...

2004-12-15

84

Investigation of respiratory-dependent movements of pulmonary space-occupying lesions with MRI; Untersuchung der atemabhaengigen Bewegungen pulmonaler Raumforderungen mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

Parallel imaging and echo sharing techniques have markedly reduced the acquisition times for MRI of large volumes. Dynamic 2 and 3-dimensional data sets of the chest with high temporal resolution (up to 10 images/s with single slice and 2 volume/s) allow an analysis of respiratory motion of the lungs and tumors. Time-resolved 2D series in preselected planes can be used to observe respiratory motion during free breathing or after respiratory commands, e.g. to exclude chest wall invasion by a tumor or for diagnosing impairment of respiratory mechanics. Time-resolved 3D-series (4D-MRI) allow monitoring of the spatial displacement of the lungs and tumors as a whole volume. Present limitations such as an overestimation of tumor size and an underestimation of displacement due to a limited temporal resolution are expected to be overcome with further technical developments. However, 4D-MRI already appears to be ...

2009-08-15

85

MRI evaluation and image processing in gel dosimetry. A study of selected MRI properties and image processing in 3D gel dosimetry  

Energy Technology Data Exchange (ETDEWEB)

Gel dosimetry is a new dosimetry method applied in radiation therapy. Gel dosimeters consist of a radiation sensitive gel, which can integrate absorbed doses from several radiation sources or beams. The dose to the gel can be evaluated by magnetic resonance imaging (MRI), a procedure that is the focus of the present thesis. A robust tool for the evaluation of the nonuniformity in MRI has been developed, the Deviation Image method. Unlike previously presented methods, the Deviation Image method includes all nonuniformity variations across a phantom surface and is insensitive to stochastic noise. Methods for the estimation of stochastic noise were analyzed in terms of sensitivity to nonuniformities. A method that averages the stochastic noise level over five regions over the phantom surface, and a method that assesses the stochastic noise level from the background, were found to be the methods of choice. Pronounced MR image nonuniformity variation with repetition and T1 relaxation time ...

2001-03-01

86

Improvement of numerical analysis method for FBR core characteristics. 2  

Energy Technology Data Exchange (ETDEWEB)

This report is composed of the following two parts and appendix. (I) Improvement of the Method for Evaluating Reactivity Based on Monte Carlo Perturbation Theory: Theoretical formulation in Monte Carlo perturbation method had been checked, and then introduced into a calculation code. There are some cases that the results of the change of eigenvalues becomes positive or negative by changing the estimator, and there is no reasonable difference in the results between the conventional method, which does not consider the change of neutron source distribution caused by a perturbation, and the new method, which consider that change. Thus it is still necessary to check the Monte Carlo perturbation code. (II) Improvement of Nodal Transport Method for 3-D Hexagonal Geometry: We can accurately evaluate hexagonal geometry FBR core by nodal transport calculation code for hexagonal-Z geometry named `NSHEX`. However it is also found that ...

1997-03-01

87

3D Fourier synthesis of a new X-ray picture identical in projection to a previous picture  

Energy Technology Data Exchange (ETDEWEB)

A central problem in diagnostic radiology is to compare a new X-ray picture with a previous picture and from this comparison be able to decide if anatomical changes have occurred in the patient or not. It is of primary interest that these pictures are identical in projection. If not it is difficult to decide with confidence if differences between the pictures are due to anatomical changes or differences in their projection geometry. In this thesis we present a non invasive method that makes it possible to find the relative changes in the projection geometry between the exposure of a previous picture and a new picture. The method presented is based on the projection slice theorem (central section theorem). Instead of an elaborate search for a single new picture a pre-planned set of pictures are exposed from a circular orbit above the patient. By using 3D Fourier transform techniques we are able to synthesize a new X-ray picture from this set of ...

1993-11-01

88

A Multi-Layered Image Cache for Scientific Visualization  

Energy Technology Data Exchange (ETDEWEB)

We introduce a multi-layered image cache system that is designed to work with a pool of rendering engines to facilitate an interactive, frameless, asynchronous rendering environment. Our system decouples the rendering from the display of imagery. Therefore, it decouples render frequency and resolution from display frequency and resolution, and allows asynchronous transmission of imagery instead of the compute/send cycle of standard parallel systems. It also allows local, incremental refinement of imagery without requiring all imagery to be re-rendered. Images are placed in fixed position in camera (vs. world) space to eliminate occlusion artifacts. Display quality is improved by increasing the number of images. Interactivity is improved by decreasing the number of images.

2003-06-26

89

Development of a 3-D model for eddy current testing: application for fastened structures in aeronautics; Developpement d'un modele pour le controle non destructif par courants de Foucault de structures rivetees en aeronautique  

Energy Technology Data Exchange (ETDEWEB)

One of the Eddy Current Testing issues in aeronautics is the inspection of fastened structures to detect flaws nearby rivets which can grow because of mechanical stress. EADS and the CEA LIST have started a collaborative work with the support of the Ile-de-France Region to develop a simulation tool of EC fastened structures testing, integrated to the CIVA platform, aimed at conceiving testing methods, optimizing and qualifying it. The volume integral method using the Green dyadics formalism has been chosen in order to get a fast resolution of Maxwell equations. A first milestone was to build a simulation model of multilayer structures testing, thanks to the use of the multilayer Green dyads. Because of the rivet volume, 60 times bigger than the one of a typical flaw, a large number of discretization cells are needed. Therefore an iterative method has been developed in order to numerically solve large calculation zones. Finally, the flaw response simulation mostly ...

2007-12-15

90

Spiral Structures and Shocks in Accretion Discs in Close Binary Systems: the Role of the Stellar Mass Ratio.  

Science.gov (United States)

% In this work we investigated, in the Smooth Particle Hydrodynamics (SPH) framework, the development of spiral structures and shock fronts in the radial flow of accretion discs in close binary systems. These shock waves take place when the initially supersonic radial flow penetrating the disc bulk, reduces substantially its speed becoming suddenly subsonic. To this purpose, keeping constant the mass of the compact primary (M1 = 1 MO ), the separation between the two components and the injection speed at the inner Lagrangian point L1 (close to the local sound speed), we carried out 2D SPH simulations for four values of the stellar mass ratio M2/M1. We worked out 2D models because the damping effect of the artificial viscosity is too strong in 3D. Furthermore, the 2D environment seems the most suitable in order to evidence shock fronts in highly compressible gases. The results show that spiral structures and shock fronts develop for low values ...

2000-06-01

91

Iterative Dense Correspondence Correction Through Bundle Adjustment Feedback-Based Error Detection  

Energy Technology Data Exchange (ETDEWEB)

A novel method to detect and correct inaccuracies in a set of unconstrained dense correspondences between two images is presented. Starting with a robust, general-purpose dense correspondence algorithm, an initial pose estimate and dense 3D scene reconstruction are obtained and bundle-adjusted. Reprojection errors are then computed for each correspondence pair, which is used as a metric to distinguish high and low-error correspondences. An affine neighborhood-based coarse-to-fine iterative search algorithm is then applied only on the high-error correspondences to correct their positions. Such an error detection and correction mechanism is novel for unconstrained dense correspondences, for example not obtained through epipolar geometry-based guided matching. Results indicate that correspondences in regions with issues such as occlusions, repetitive patterns and moving objects can be identified and corrected, such that a more ...

2009-11-23

92

Applications with a new low-temperature UHV STM at 5 K  

International Nuclear Information System (INIS)

A new dedicated UHV STM for investigations at T#<=#5 K is presented. To achieve such low temperatures and to ensure a high thermal stability, the low-temperature (LT) STM described here has a concentric system of bath cryostats. There are openings for tip and sample exchange at low T, and windows with an infrared radiation shield for optical access, which can both be closed by a door mechanism for LT-STM measurements. Efficient vibration isolation is realized by using spring suspension with eddy current damping. With the 3-d coarse positioning unit any region of interest within 5 mm by 5 mm on the sample is accessible even at 5 K. For short turn-around cycles the sample and tip can both be exchanged at low temperatures. Atomically resolved images of Au(111) at 5 K in UHV demonstrate the excellent performance of this LT STM. As a typical application example the appearance of a charge-density wave on NbSe_2, which occurs ...

1998-03-01

93

TECAB - Totally Endoscopic Coronary Artery Bypass  

Medline Plus

... CT angiograph for the peripheral rteries. a beautiful 3D-vision on the structures inside e chest. Okay. ... have an angled camera here. This is a 3D camera, and the surgeon has got th What ...

94

JAtlasView: a Java atlas-viewer for browsing biomedical 3D images and atlases  

UK PubMed Central (United Kingdom)

BackgroundMany three-dimensional (3D) images are routinely collected in biomedical research and a number of digital atlases with associated anatomical and other information have...Full Text Available

95

Ct3d: tracking microglia motility in 3D using a novel cosegmentation approach  

UK PubMed Central (United Kingdom)

Motivation: Cell tracking is an important method to quantitatively analyze time-lapse microscopy data. While numerous methods and tools exist for tracking cells in 2D time-lapse images,...Full Text Available

2011-02-15

96

Catheter Ablation for Paroxysmal Atrial Fibrillation  

Medline Plus

... catheter ablation for paroxysmal atrial fibrillation procedure utilizing 3-D mapping and rotational intracardiac echocardiography. This program is ... of the MRI scan and then there's the 3-D image, which is generated from the pixels chosen ...

97

Automated 3-D method for the correction of axial artifacts in spectral-domain optical coherence tomography images  

UK PubMed Central (United Kingdom)

The 3-D spectral-domain optical coherence tomography (SD-OCT) images of the retina often do not reflect the true shape of the retina and are distorted differently along the x and y...Full Text Available

98

Accuracy of Contacts Calculated from 3D Images of Occlusal Surfaces  

UK PubMed Central (United Kingdom)

ObjectiveCompare occlusal contacts calculated from 3D virtual models created from clinical records to contacts identified clinically using shimstock and transillumination.Full Text Available

2007-06-01

99

A frequency-based approach to locate common structure for 2D-3D intensity-based registration of setup images in prostate radiotherapy  

UK PubMed Central (United Kingdom)

In many radiotherapy clinics, geometric uncertainties in the delivery of 3D conformal radiation therapy and intensity modulated radiation therapy of the prostate are reduced by aligning the...Full Text Available

2007-07-01

100

Surgical navigation using audio feedback.  

Science.gov (United States)

Current medical visualization technology intended for positional guidance in surgical applications may only ever have limited utility in the operating room due to the preexisting visual requirements of surgical practice. Additionally, visual systems impose limits as a result of their high latency, poor image resolution, problems with stereopsis and physical strain upon the user. Audio technology is relatively unexamined in the broad range of available methodologies for medical devices. The potential to translate surgical instrument position into audio feedback presents a novel solution to the human factors and engineering problems faced by visual display technology because audio technology employs a rich and as yet unburdened sensory modality. We describe an experimental system we have developed for investigating this new interface design approach using commercially available hardware. PMID:10173065

1997-01-01

101

Reborn quadrant anode image sensor  

International Nuclear Information System (INIS)

We describe a position sensitive photon counting microchannel plate based detector with an improved quadrant anode (QA) readout system. The technique relies on a combination of the four planar elements pattern and an additional fifth electrode. The charge cloud induced by single particle detection is split between the electrodes. The measured charge values uniquely define the position of the initial event. QA has been first published in 1976 by Lampton and Malina. This anode configuration was undeservedly forgotten and its potential has been hardly underestimated. The presented approach extends the operating spatial range to the whole sensitive area of the microchannel plate surface and demonstrates good linearity over the field of view. Therefore, the novel image sensor results in spatial resolution better then 50?m and count rates up to one million events per second.

2009-06-01

102

A method to study heavy ion reactions using position sensitive and Bragg curve spectroscopy detectors  

Energy Technology Data Exchange (ETDEWEB)

A large area Bragg curve spectroscopy (BCS) detector and a position sensitive parallel grid avalanche counter have been developed to study heavy ion reactions, such as inelastic excitations and few nucleon transfer reactions near the Coulomb barrier. Reasonably good resolutions have been achieved for energy, atomic number and angle. A theoretical investigation on the mass dependence of the Bragg peak signal from the BCS detector, shows that there is a negligible mass dependence related to the geometry of the detector. The mass number of the heavy ions which cannot be obtained by the above method, has been identified by detecting the corresponding characteristic gamma rays from the product nuclei with two large solid angle gamma ray detectors. (orig.)

1993-10-15

103

A method to study heavy ion reactions using position sensitive and Bragg curve spectroscopy detectors  

International Nuclear Information System (INIS)

A large area Bragg curve spectroscopy (BCS) detector and a position sensitive parallel grid avalanche counter have been developed to study heavy ion reactions, such as inelastic excitations and few nucleon transfer reactions near the Coulomb barrier. Reasonably good resolutions have been achieved for energy, atomic number and angle. A theoretical investigation on the mass dependence of the Bragg peak signal from the BCS detector, shows that there is a negligible mass dependence related to the geometry of the detector. The mass number of the heavy ions which cannot be obtained by the above method, has been identified by detecting the corresponding characteristic gamma rays from the product nuclei with two large solid angle gamma ray detectors. (orig.).

104

Stereotactic Radiation Therapy for Brain Tumors  

Medline Plus

... acquired, which we then volumetrically fuse with the 3D image set from the MR. And by doing ...

105

Monovision  

Medline Plus

... Exercises: Day and Night Classroom Exercises: Pinhole Focusing 3D Vision and Eye Health < Contact Lenses Monovision Playlist: ...

106

Debris Dispersion Model Using Java 3D  

Science.gov (United States)

This paper describes web based simulation of Shuttle launch operations and debris dispersion. Java

2004-01-01

107

Contact Lenses  

Medline Plus

... Exercises: Day and Night Classroom Exercises: Pinhole Focusing 3D Vision and Eye Health < Caring for Your Vision ...

108

Vibration signature analysis of AFM images  

Energy Technology Data Exchange (ETDEWEB)

Vibration signature analysis has been commonly used for the machine condition monitoring and the control of errors. However, it has been rarely employed for the analysis of the precision instruments such as an atomic force microscope (AFM). In this work, an AFM was used to collect vibration data from a sample positioning stage under different suspension and support conditions. Certain structural characteristics of the sample positioning stage show up as a result of the vibration signature analysis of the surface height images measured using an AFM. It is important to understand these vibration characteristics in order to reduce vibrational uncertainty, improve the damping and structural design, and to eliminate the imaging imperfections. The choice of method applied for vibration analysis may affect the results. Two methods, the data dependent systems (DDS) analysis and the Welch`s periodogram averaging method were investigated for application ...

1995-12-31

109

Pulse Rise Time Characterization of a High Pressure Xenon Gamma Detector for use in Resolution Enhancement  

CERN Document Server

High pressure xenon ionization chamber detectors are possible alternatives to traditional thallium doped sodium iodide (NaI(Tl)) and hyperpure germanium as gamma spectrometers in certain applications. Xenon detectors incorporating a Frisch grid exhibit energy resolutions comparable to cadmium/zinc/telluride (CZT) (e.g. 2% (at) 662keV) but with far greater sensitive volumes. The Frisch grid reduces the position dependence of the anode pulse risetimes, but it also increases the detector vibration sensitivity, anode capacitance, voltage requirements and mechanical complexity. We have been investigating the possibility of eliminating the grid electrode in high-pressure xenon detectors and preserving the high energy resolution using electronic risetime compensation methods. A two-electrode cylindrical high pressure xenon gamma detector coupled to time-to-amplitude conversion electronics was used to characterize the pulse rise ...

2000-01-01

110

Pseudocraters as indicators of ground ice on Mars  

International Nuclear Information System (INIS)

Positive identification of Martian pseudocraters would be a strong indication of past occurrence of ice at or near the surface of Mars. The basis for suggesting that small cones on Mars are pseudocraters includes: (1) small size, (2) abundant but patchy distribution on what appear to be volcanic plains, (3) presence of other features suggestive of surface or subsurface ice, (4) morphological similarities to Icelandic pseudocraters, and (5) the similarity in distribution of crater/cone diameter ratios to Icelandic pseudocraters. This last morphometric parameter may be the most important, since other possible small terrestrial volcanic analogs have very different crater/cone diameter ratio distributions. In a survey of the available high resolution Viking Orbiter imagery, abundant fields of possible pseudocraters were found. However, only a small fraction of the plains forming units imaged at high resolution were found to ...

1987-05-01

111

Instability of 4f and 3d magnetic moments under high pressure  

International Nuclear Information System (INIS)

The purpose of this paper is to demonstrate how recent experimental results of "1"5"1Eu and "5"7Fe high pressure Moessbauer studies in 4f and 3d metallic magnetic systems can contribute to a deeper understanding of the nature of local moment (4f) and itinerant (3d) magnetism in these systems. Special emphasis is given on the comparison of the experimental results with related theoretical models. (orig.).

112

Competitive degradation between the fumigants chloropicrin and 1,3-dichloropropene in unamended and amended soils.  

Science.gov (United States)

The mixture of 1,3-dichloropropene (1,3-D) and chloropicrin (CP) is used as a preplant soil fumigant. In comparison with individual fumigants, application of a mixture may affect the environmental dissipation and fate of each chemical, such as emission and degradation. We investigated the degradation of CP, 1,3-D, and their mixture in fresh soils and sterile soils, and evaluated the competitive characteristic of fumigants in the mixture. The degradation of low concentrations of CP in fresh soil was accelerated at early times in the presence of 1,3-D, whereas the addition of CP reduced the degradation rate of trans-1,3-D, possibly by inhibiting the activity of trans-1,3-D degrading microorganisms. The potential of applying amendments to the soil to increase the rate of CP and ...

113

Calculated valence electronic structure of 3d metals for use in the X-ray intensity ratio studies  

Energy Technology Data Exchange (ETDEWEB)

3d occupation numbers of the transition elements corresponding to various types of atomic configurations are calculated by means of the linear muffin-tin orbital (LMTO) method. This data is used with the multiconfiguration Dirac-Fock (MCDF) X-ray intensity ratios to estimate the electron populations of the 3d metals in alloys.

2010-09-15

114

Calculated valence electronic structure of 3d metals for use in the X-ray intensity ratio studies  

International Nuclear Information System (INIS)

3d occupation numbers of the transition elements corresponding to various types of atomic configurations are calculated by means of the linear muffin-tin orbital (LMTO) method. This data is used with the multiconfiguration Dirac-Fock (MCDF) X-ray intensity ratios to estimate the electron populations of the 3d metals in alloys.

2010-09-01

115

3D rotational angiography: Benefits obtained in clinical endovascular treatments  

International Nuclear Information System (INIS)

The application of 3D rotational angiography marks a breakthrough in endovascular treatment of aneurysmas of the brain. 3D images are produced based on image series obtained by rotational angiography, so that the anatomic details of interest can be visualized from any requested angle. (orig./CB)

1999-01-01

116

State analysis of sulfur in coal and coal fly ash by double-crystal X-ray fluorescence spectrometry  

Energy Technology Data Exchange (ETDEWEB)

Double-crystal high-resolution x-ray fluorescence spectrometry was applied to the state analysis of sulfur in coal and related fly ash. For total sulfur, a proportional relationship exists between fluorescence intensities and the analytical values obtained by the oxygen-combustion method. Two oxidation states of sulfur were identified by a least square curve fitting method, by assuming that the spectrum profile is identical for each sulfur state but the intensity and position are different. The chemical state of sulfur in coal and remaining in fly ash is discussed.

1983-01-01

117

Smart Acquisition EELS  

Energy Technology Data Exchange (ETDEWEB)

Electron energy loss (EEL) spectroscopy and high angle annular dark field (HAADF) imaging in aberration-corrected electron microscopes are powerful techniques to determine the chemical composition and structure of materials at atomic resolution. We have implemented Smart Acquisition, a flexible system of scanning transmission electron microsocpy (STEM) beam position control and EELS collection, on two aberration-corrected dedicated cold field emission gun (FEG) STEMs located at SuperSTEM, Daresbury Laboratory. This allows the collection of EEL spectra from spatially defined areas with a much lower electron dose possible than existing techniques such as spectrum imaging.

2010-07-01

118

Breast imaging with a dedicated PEM  

International Nuclear Information System (INIS)

During the last decade there was a growing interest on the application of Positron Emission Tomography, PET, techniques to Breast Imaging. More recently, preliminary results suggested the use of dedicated devices to Breast Imaging using the same technique, the so-called Positron Emission Mammography cameras, PEM. In this article we review the arguments leading to a dedicated instrument. Based on these arguments we describe the concept of a PEM camera under development within the Crystal Clear Collaboration and the first results of its expected performance in terms of sensitivity and position resolution.

2004-07-11

119

Considerations for the next Compton telescope mission  

International Nuclear Information System (INIS)

A high resolution Compton telescope has been identified by the Gamma Ray Astronomy Program Working Group (GRAPWG) as the highest priority major mission in gamma ray astrophysics following GLAST. This mission should provide 25-100 times improved sensitivity, relative to CGRO and INTEGRAL, for MeV gamma ray lines. It must have good performance for narrow and broad lines and for discrete and diffuse emissions. Several instrumental approaches are being pursued to achieve these goals. We discuss issues relating to this mission including alternative detector concepts, instrumental configurations, and background reduction techniques. We have pursued the development of position-sensitive solid-state detectors (Ge, Si) for a high spectral resolution Compton telescope mission. A #approx#1 m2 germanium Compton telescope of position-sensitive germanium detectors was the basis for one of the GRAPWG concepts. ...

2000-04-12

120

The application of high resolution sequence stratigraphy to reservoir zonation and management of the Beryl Field  

Energy Technology Data Exchange (ETDEWEB)

Tidally dominated sections from the Middle Jurassic Beryl Formation of the Beryl Field, Viking Graben (UKCS) were deposited during rapid changes in relative sea level. High density well coverage in this key producing interval has allowed the construction of an integrated high resolution sequence stratigraphic scheme based on sedimentological, ichnofaunal, wireline, biostratigraphic and engineering data. From this database a number of high resolution sequences in the Bajocian-Bathonian Beryl Formation have been identified composed of interbedded sandstones, siltstones and mudstones. These sediments formed tidally-influenced deltas and estuaries deposited in actively subsiding half-grabens during regionally extensive base-level changes. For reservoir management purposes, the formation has been split into 5 units. The thickest interval, Unit 3, is considered here. In the northern part of the Beryl Field, Unit 3 is bounded above and below by ...

1996-08-01

121

A proposition of 3D inertial tolerancing to consider the statistical combination of the location and orientation deviations  

CERN Document Server

Tolerancing of assembly mechanisms is a major interest in the product life cycle. One can distinguish several models with growing complexity, from 1-dimensional (1D) to 3-dimensional (3D) (including form deviations), and two main tolerancing assumptions, the worst case and the statistical hypothesis. This paper presents an approach to 3D statistical tolerancing using a new acceptance criterion. Our approach is based on the 1D inertial acceptance criterion that is extended to 3D and form acceptance. The modal characterisation is used to describe the form deviation of a geometry as the combination of elementary deviations (location, orientation and form). The proposed 3D statistical tolerancing is applied on a simple mechanism with lever arm. It is also compared to the traditional worst-case tolerancing using a tolerance ...

2010-01-01

122

3-D prestack migration in anisotropic media  

Energy Technology Data Exchange (ETDEWEB)

A three-dimensional (3-D) prestack reverse-time migration algorithm for common-source P-wave data from anisotropic media is developed and illustrated by application to synthetic data. Both extrapolation of the data and computation of the excitation-time imaging condition are implemented using a second-order finite-difference solution of the 3-D anisotropic scalar-wave equation. Poorly focused, distorted images are obtained if data from anisotropic media are migrated using isotropic extrapolation; well focused, clear images are obtained using anisotropic extrapolation. A priori estimation of the 3-D anisotropic velocity distribution is required. Zones of anomalous, directionally dependent reflectivity associated with anisotropic fracture zones are detectable in both the 3-D common-source data and the corresponding ...

1993-01-01

123

3-D depth migration via McClellan transformations  

Energy Technology Data Exchange (ETDEWEB)

Three-dimensional seismic wavefields may be extrapolated in depth, one frequency at a time, by two-dimensional convolution with a circularly symmetric, frequency- and velocity-dependent filter. This depth extrapolation, performed for each frequency independently, lies at the heart of 3-D finite-difference depth migration. The computational efficiency of 3-D depth migration depends directly on the efficiency of this depth extrapolation. McClellan transformations provide an efficient method for both designing and implementing two-dimensional digital filters that have a particular form of symmetry, such as the circularly symmetric depth extrapolation filters used in 3-D depth migration. Given the coefficients of one-dimensional, frequency- and velocity-dependent filters used to accomplish 2-D depth migration, McClellan transformations lead to a simple and efficient ...

1990-01-01

124

Creating an EPICS Based Test Stand Development System for a BPM Digitizer of the Linac Coherent Light Source  

Energy Technology Data Exchange (ETDEWEB)

The Linac Coherent Light Source (LCLS) is required to deliver a high quality electron beam for producing coherent X-rays. As a result, high resolution beam position monitoring is required. The Beam Position Monitor (BPM) digitizer acquires analog signals from the beam line and digitizes them to obtain beam position data. Although Matlab is currently being used to test the BPM digitizer?s functions and capability, the Controls Department at SLAC prefers to use Experimental Physics and Industrial Control Systems (EPICS). This paper discusses the transition of providing similar as well as enhanced functionalities, than those offered by Matlab, to test the digitizer. Altogether, the improved test stand development system can perform mathematical and statistical calculations with the waveform signals acquired from the digitizer and compute the fast Fourier transform (FFT) of the signals. Finally, logging of ...

2011-06-22

125

Direct Comparison of the X-Ray Emission and Absorption of Cerium Oxide  

Energy Technology Data Exchange (ETDEWEB)

Bremstrahlung Isochromat Spectroscopy (BIS). The XES spectra were collected using a Specs electron gun for the excitation and the XES 350 grating monochromator and channel plate system from Scienta as the photon detection. Spectra were collected in 'normal mode,' where the electron gun kinetic energy (KE) and the energy position of the center of the channel plate were both fixed and the energy distribution in the photon (hv) spectrum was derived from the intensities distributed across the channel plate detector in the energy dispersal direction. The polycrystalline Ce sample was oxidized by exposure to air at ambient pressures. After introduction to the ultra-high vacuum system, the oxidized sample was bombarded with Ar, to clean the topmost surface region and stabilize the surface and near surface regions. Although CeO{sub 2} would be the thermodynamically preferred composition in an oxygen rich environment, the combination of a vacuum ...

2010-11-24

126

Morphometric analysis of the temporomandibular joint with MRI in 320 joints; Morphometrische Analyse des Kiefergelenkes anhand von 320 Gelenken mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

Purpose: to compare several morphometric parameters in MRI with the functional status of the articular disc in a large patient group suffering from internal derangement (ID) of the temporomandibular joint (TMJ). Materials and methods: in a retrospective study, 320 analyzable high resolution MRI examinations of the TMJs obtained in a 1.5 T unit were evaluated in 184 patients with clinically suspected ID. The analysis included the anatomical structures and a number of morphometric parameters previously described in the literature. The parameters were compared with the position of the articular disc. Results: the disc position was categorized as ''normal'' (NDP, 21.9%, n = 70), ''anterior displacement with reduction on opening'' (AMR, 51.6%, n = 165) and ''anterior displacement without reduction on opening'' (AOR, 26.6%, ...

2005-02-01

127

CT colonography: techniques of visualization and findings; CT Kolonographie: Techniken der Visualisierung und Befundung  

Energy Technology Data Exchange (ETDEWEB)

Evaluation and interpretation of CT colonography is based on both 2D and 3D techniques. The 2D techniques are popular mainly because the time needed for evaluation is short. The 3D techniques allow better definition than the 2D techniques, especially of polyps close to folds or at the base of a fold. The evaluation strategies generally accepted so far (primarily 2D, with 3D for problem cases, or vice versa) demand knowledge of both 2D and 3D techniques. Newer 3D visualization techniques help make it possible to acquire more complete and faster recording particularly of areas that are not easily accessible to endoscopic examination. These user-friendly developments are thus well suited to improving the detection and the security of detection of polyps. It must be remembered that ...

2008-02-15

128

Recent developments and applications for the University of Texas thermal neutron imaging facility  

Energy Technology Data Exchange (ETDEWEB)

The full text follows. A thermal neutron imaging facility (TNIF) capable of real time neutron radiography and computed tomography was developed for the University of Texas TRIGA Mark II (UT-TRIGA) reactor from 1994-1998. The facility was developed with a through reactor beam port capable of producing a 5.2 x 10{sup 6} n/cm{sup 2}/s thermal neutron flux with a gamma dose rate of less than 1 mR/s after collimation. The original TNIF included the UT-TRIGA reactor, neutron collimation array, sample positioning system, neutron image intensifier tube, video camera, computerized image acquisition system, and a radiation shield. A 0.7 mm slit in cadmium was easily detectable using neutron radiography, and 1.4 mm diameter holes bored in an aluminum block were easily resolved using computed neutron tomography. Precise lower limits of the system resolution have hot been determined. The TNIF is currently being revamped to begin work with the ...

2001-07-01

129

An integrated Tomographic Gamma Scanning system for non-destructive assay of radioactive waste  

Energy Technology Data Exchange (ETDEWEB)

The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm{sup -3} or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant ...

2007-08-21

130

An integrated Tomographic Gamma Scanning system for non-destructive assay of radioactive waste  

International Nuclear Information System (INIS)

The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm"-"3 or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant applications. ...

2007-08-21

131

Advanced Simulation and Computing FY10-FY11 Implementation Plan Volume 2, Rev. 0.5  

Energy Technology Data Exchange (ETDEWEB)

The Stockpile Stewardship Program (SSP) is a single, highly integrated technical program for maintaining the surety and reliability of the U.S. nuclear stockpile. The SSP uses past nuclear test data along with current and future non-nuclear test data, computational modeling and simulation, and experimental facilities to advance understanding of nuclear weapons. It includes stockpile surveillance, experimental research, development and engineering (D&E) programs, and an appropriately scaled production capability to support stockpile requirements. This integrated national program requires the continued use of current facilities and programs along with new experimental facilities and computational enhancements to support these programs. The Advanced Simulation and Computing Program (ASC) is a cornerstone of the SSP, providing simulation capabilities and computational resources to support the annual stockpile assessment and certification, to study advanced nuclear weapons design ...

2009-09-08

132

Submarine tsunamigenic landslides at Stromboli Volcano: characterization and estimation of recurrence time  

Science.gov (United States)

Seafloor mapping and morphometric analysis of landslide scars can provide useful insights for marine geo-hazard assessment, as demonstrated by several studies performed on different geological settings. The availability of high-resolution multibeam bathymetry and long-range side scan sonar data on the submarine portions of Stromboli Volcano allow us to map and characterize the main mass-wasting features that affect, on the whole, about the 90% of its submarine extension. In particular, two main kinds of tsunamigenic landslides have been recognized and analyzed. Large-scale sector collapses (Fig. 1) are catastrophic events that mobilize 1-2 cubic kilometers of material, generating huge tsunami waves that may affect Stromboli and propagate in surrounding areas; related hazard is not very high, as they show recurrence periods of some (or more) thousand years. Conversely, medium-scale landslides are more hazardous, as they occur at higher frequency with respect to the ...

2010-12-01

133

Interpretation of quasi-Fermi level splitting in Cu(Ga,In)Se2-absorbers by confocally recorded spectral luminescence and numerical modeling  

International Nuclear Information System (INIS)

Spectral room temperature photoluminescence (pl) of polycrystalline Cu(In,Ga)Se2 films (CIGSe) is evaluated with respect to optoelectronic properties and in particular for the determination of the splitting of quasi-Fermi levels (EFn - EFp). For lateral resolution of ? 1 ?m a confocal pl-setup is used. The depth profile of the excess carrier densities determining the rates of radiative transitions strongly govern the spectral pl-shape which has been numerically modeled with a matrix transfer formalism. In this optical approach we discriminate for wave propagation and attenuation in a multilayer system between a plane-wave ansatz and a 3D-spherical formalism, depending on excitation area large or small/similar compared to the thickness of the absorber. In both cases re-absorption of photons in energetic regimes with absorption approaches unity, from which the splitting of the quasi-Fermi levels is preferentially deduced, ...

2009-02-02

134

Automatic segmentation of thoracic and pelvic CT images for radiotherapy planning using implicit anatomic knowledge and organ-specific segmentation strategies  

Energy Technology Data Exchange (ETDEWEB)

Automatic segmentation of anatomical structures in medical images is a valuable tool for efficient computer-aided radiotherapy and surgery planning and an enabling technology for dynamic adaptive radiotherapy. This paper presents the design, algorithms and validation of new software for the automatic segmentation of CT images used for radiotherapy treatment planning. A coarse to fine approach is followed that consists of presegmentation, anatomic orientation and structure segmentation. No user input or a priori information about the image content is required. In presegmentation, the body outline, the bones and lung equivalent tissue are detected. Anatomic orientation recognizes the patient's position, orientation and gender and creates an elastic mapping of the slice positions to a reference scale. Structure segmentation is divided into localization, outlining and refinement, performed by procedures with implicit anatomic knowledge ...

2008-03-21

135

An improved model for natural convection heat loss from modified cavity receiver of solar dish concentrator  

Energy Technology Data Exchange (ETDEWEB)

A 2-D model has been proposed to investigate the approximate estimation of the natural convection heat loss from modified cavity receiver of without insulation (WOI) and with insulation (WI) at the bottom of the aperture plane in our previous article. In this paper, a 3-D numerical model is presented to investigate the accurate estimation of natural convection heat loss from modified cavity receiver (WOI) of fuzzy focal solar dish concentrator. A comparison of 2-D and 3-D natural convection heat loss from a modified cavity receiver is carried out. A parametric study is carried out to develop separate Nusselt number correlations for 2-D and 3-D geometries of modified cavity receiver for estimation of convective heat loss from the receiver. The results show that the 2-D and 3-D are comparable only at higher angle of ...

2009-10-15

136

High-resolution sequence stratigraphy of a Hettangian-Sinemurian parallic succession, Bornholm, Denmark  

Energy Technology Data Exchange (ETDEWEB)

Sequence stratigraphic interpretation of paralic successions is complicated by the complex interfingering of marine and continental strata. The successions may also include terrestrial extensions of marine parasequences and completely independent lacustrine parasequence analogues. Failure in recognizing the possible interbedding of these two independent parasequence types may lead to construction of sequence stratigraphic schemes based on incompatible data sets. We have studied a Lower Jurassic paralic section from the Baltic island of Bornholm. The Hettangian-Sinemurian Sose Bugt Member (Ronne Formation) of Bornholm includes lacustrine, fluvial and restricted marine, estuarine deposits reflecting the basin-margin position. Biostatigraphic resolution is poor and a sequence stratigraphic interpretation of the paralic succession is far from straightforward. A multidisciplinary approach including facies analysis, recognition and lateral tracting ...

1995-04-01

137

Turbulence in the positive column of a glow discharge  

CERN Document Server

Turbulence in the positive column of a glow discharge

1969-01-01

138

Collaboration work for nuclear power building using 3D CAD information  

Energy Technology Data Exchange (ETDEWEB)

In the construction work for the Unit No.5 Turbine Building at Hamaoka Nuclear Power Station, the collaboration work for the planning and the coordination of the building construction and the machinery installation was carried out utilizing three-dimensional computer aided design (3D CAD) information. It was the first time in Japan for a building constructor and a plant manufacturer to work together, exchanging 3D CAD data of the whole building and adjusting the construction schedule. It was made possible to confirm the correspondence concerning the planning of both companies from the primary stage of the project by the total process simulation and to adjust on-going work precisely by the partial process simulation.

2006-02-15

139

Collaboration work for nuclear power building using 3D CAD information  

International Nuclear Information System (INIS)

In the construction work for the Unit No.5 Turbine Building at Hamaoka Nuclear Power Station, the collaboration work for the planning and the coordination of the building construction and the machinery installation was carried out utilizing three-dimensional computer aided design (3D CAD) information. It was the first time in Japan for a building constructor and a plant manufacturer to work together, exchanging 3D CAD data of the whole building and adjusting the construction schedule. It was made possible to confirm the correspondence concerning the planning of both companies from the primary stage of the project by the total process simulation and to adjust on-going work precisely by the partial process simulation.

2006-02-01

140

Technical Evaluation Report  

Science.gov (United States)

... and/or hearing mechanisms. Seven papers dealt with 3D audio technology and/or its application. Eight papers presented ...

2005-04-01

141

Tackling the Steroid Issue: Squeezing Out the Juice  

Medline Plus

... Neglect (12) Co-Occurring Disorders (75) Conduct Disorders (3) D Dementia (2) Depression (51) Driving While Intoxicated (17) ...

142

English version - Guidelines for Viability Assessment - CAP Workbook version 3_d  

Science.gov (United States)

Guidelines for the viability primer component of the version 3 workbook. The Viability page in the current version of the Excel spreadsheet for conservation ... ...

145

An improved model for natural convection heat loss from modified cavity receiver of solar dish concentrator  

British Library Electronic Table of Contents (United Kingdom)

A 2-D model has been proposed to investigate the approximate estimation of the natural convection heat loss from modified cavity receiver of without insulation (WOI) and with insulation (WI) at the bottom of the aperture plane in our previous article. In this paper, a 3-D numerical model is presented to investigate the accurate estimation of natural convection heat loss from modified cavity receiver (WOI) of fuzzy focal solar dish concentrator. A comparison of 2-D and 3-D natural convection heat loss from a modified cavity receiver is carried out. A parametric study is carried out to develop separate Nusselt number correlations for 2-D and 3-D geometries of modified cavity receiver for estimation of convective heat loss from the receiver. The results show that the 2-D and 3-D are comparabl...

2009-01-01

146

Advanced 3D Visualization Web Technology and its Use in ...  

Science.gov (United States)

... applications related to military and intelligence area ... the technology solved yet, but the open issue still ... fields, columns; ie data source, document type ...

2002-04-01

147

AIAA 20033400 CFD Sensitivity Analysis ... - FUN3D Manual - NASA  

Science.gov (United States)

mulation, with flow quantities stored at the grid vertices. OVERFLOW ..... attack: a separation bubble near the trailing edge of the ..... AGARD CP-429, Jul. 1988. ...

148

3-D brain CT image display for planning of craniofacial operation  

International Nuclear Information System (INIS)

The authors have been developing a 3D brain CT image display system for planning of craniofacial operations. This system helps doctors plan craniofacial operations on a graphic display (GD) terminal by rendering 3D images reconstructed from a set of slices. The authors reveal how the system generates 3D shapes of organs from given CT images and how it modifies or transforms the obtained shapes according to the user's request. The system functions now available are extraction and display of the skull and the skin, measurement of the distance between two points on the skull given through the GD terminal, and generating and eliminating a polygonal region arbitrarily given on the skull as an operative region. (Auth.).

149

Theoretical considerations for X-ray phase contrast mammography by Thomson source  

Energy Technology Data Exchange (ETDEWEB)

The advent, in the near future, of compact X-ray sources like Thomson Back-Scattering (TBS) will allow the clinical application of advanced X-ray imaging techniques, such as phase contrast, with higher sensitivity and lower impact in terms of dose delivery. In this work, we theoretically investigated the possibility of using such sources for phase contrast imaging of micro-calcifications included in a breast tissue. In our study we analyzed the phase and amplitude distribution of the TBS source and we showed that this source can be used for phase contrast imaging since the source coherence at the sample position is sufficiently high for achieving good contrast and micrometer spatial resolution. Indeed the spatial coherence of a TBS source is closer to that of a synchrotron radiation source, and much better than that of a laboratory source. Moreover, we showed the advantages of phase imaging with respect to standard absorption imaging, in the ...

2009-09-01

150

State analysis of sulfur in coal and coal fly ash by double-crystal X-ray fluorescence spectrometry  

Energy Technology Data Exchange (ETDEWEB)

Double-crystal high-resolution X-ray fluorescence spectrometry was applied to the state analysis of sulfur in coal and related fly ash. For total sulfur, a proportional relationship exists between fluorescence intensities and the analytical values obtained by the oxygen-combustion method. Two oxidation states of sulfur were identified by a least square curve fitting method, by assuming that the spectrum profile is identical for each sulfur state but the intensity and the position are different. Sulfur in coal mainly consists of S/sup 2 -/, whereas that in coal fly ash mainly consists of S/sup 6 +/. As much as 0.04-0.08% of S/sup 2 -/ remains in fly ash.

1983-01-01

151

Social Skills Training for Taiwanese Students at Risk for Emotional and Behavioral Disorders  

Science.gov (United States)

Two third-grade Taiwanese students at risk for emotional and behavioral disorders participated in a pull-out, small-group social skills training program developed to promote their skill acquisition and maintenance. Using a multiple baseline across skills design, the authors demonstrated that both participants made marked performance improvement in all three targeted social skills of on-task, appropriate conflict resolution, and cooperation during the intervention condition. Maintenance and follow-up data showed that both participants sustained their use of taught social skills in the training setting and their third-grade classroom, respectively. Social validity measures, including peer sociometric ratings and consumer satisfaction questionnaires and interviews, supported the positive effects of the social skills training program for both participants. Implications for research and practice are discussed. (Contains 2 tables and 2 figures.)

2010-09-01

152

Results from a Prototype Chicane-Based Energy Spectrometer for a Linear Collider  

Energy Technology Data Exchange (ETDEWEB)

The International Linear Collider (ILC) and other proposed high energy e{sup +}e{sup -} machines aim to measure with unprecedented precision Standard Model quantities and new, not yet discovered phenomena. One of the main requirements for achieving this goal is a measurement of the incident beam energy with an uncertainty close to 10{sup -4}. This article presents the analysis of data from a prototype energy spectrometer commissioned in 2006-2007 in SLAC's End Station A beamline. The prototype was a 4-magnet chicane equipped with beam position monitors measuring small changes of the beam orbit through the chicane at different beam energies. A single bunch energy resolution close to 5 {center_dot} 10{sup -4} was measured, which is satisfactory for most scenarios. We also report on the operational experience with the chicane-based spectrometer and suggest ways of improving its performance.

2011-02-28

153

Mesenchymal stem cell transplantation for diffuse alveolar hemorrhage in SLE  

British Library Electronic Table of Contents (United Kingdom)

Background. A 19-year-old girl was diagnosed with systemic lupus erythematosus, based on findings of arthritis, malar rash, positive antinuclear antibody test and high levels of antibodies to double-stranded DNA. Two months after diagnosis, the patient presented with a sudden drop in blood hemoglobin level. Several days later, she developed bloody sputum, rapidly progressive dyspnea and hypoxemia. High-resolution CT showed diffuse alveolar infiltrates in both lung fields.Investigations. Physical examination, complete blood count, erythrocyte sedimentation rate, urinalysis, 24-h urine protein excretion, fecal occult blood test, d-dimer test, acid hemolysis test, activated partial thromboplastin time and prothrombin time, direct and indirect Coombs tests, bone marrow smear, arterial blood ga...

2010-01-01

154

Hybrid Camera Surveillance System Using Robust Human Detection  

Science.gov (United States)

We propose a novel surveillance system that uses hybrid camera network. The system contains a panorama camera and PTZ cameras to take the wide range images and face images at high enough resolution for identification tasks. The robust human detection methods include robust background subtraction method (RRC), skin color segmentation and face tracking method. First, the system detects persons from a panorama image, and then the detailed face images are obtained with the PTZ cameras. The PTZ cameras can track the faces using the four directional features and the relaxation matching. In addition, the system has automatic camera position calibration feature. Thus, the user can use the system without any troublesome settings.

2007-01-01

155

Generation of coherent states of photon-added type via pathway of eigenfunctions  

International Nuclear Information System (INIS)

We obtain and investigate the regular eigenfunctions of simple differential operators xr dr+1/dxr+1, r = 1, 2, ..., with the eigenvalues equal to 1. With the help of these eigenfunctions, we construct a non-unitary analogue of a boson displacement operator which will be acting on the vacuum. In this way, we generate collective quantum states of the Fock space which are normalized and equipped with the resolution of unity with the positive weight functions that we obtain explicitly. These states are thus coherent states in the sense of Klauder. They span the truncated Fock space without first r lowest-lying basis states: |0), |1), ..., |r - 1). These states are squeezed, sub-Poissonian in nature and reminiscent of photon-added states in Agarwal and Tara (1991 Phys. Rev. A 43 492).

2010-09-17

156

Finite element analysis of a scanning x-ray microscope micropositioning stage  

Energy Technology Data Exchange (ETDEWEB)

A micropositioning stage for use with an x-ray microscope has been developed to scan samples over a 100 {mu}m{times}100-{mu}m area with a resolution of 100 A. The stage employs flexure hinges driven by piezoelectric actuators to achieve this high positioning accuracy. Due to the severe geometry of the hinges, stresses and deflections are determined (via finite element methods) to ensure a credible design. Since the stage is to be used in a stepping capacity, natural frequencies are computed to identify resonant conditions which could potentially cause excessive deflections. The finite element models show that the stage responds like a discrete lumped-mass system for the lower modes, and a continuous system with flexural characteristics for the higher modes.

1992-01-01

157

Extrinsic allergic alveolitis induced by the yeast Debaryomyces hansenii.  

Science.gov (United States)

A 65-yr-old female developed cough, fever and dyspnoea following repeated exposure to a home ultrasonic humidifier. High-resolution computed tomography showed ground-glass opacity in both lung fields. Arterial blood gas analysis gave an oxygen tension of 8.38 kPa (63 Torr). Pulmonary function testing revealed restrictive ventilatory impairment with a reduction in the diffusing capacity. The diagnosis of extrinsic allergic alveolitis (EAA) was confirmed by radiographic findings, pathological evidence of alveolitis and reproductive development by a provocation test to the humidifier water. The yeast Debaryomyces Hansenii was the only microorganism cultured from the water of the humidifier. The double diffusion precipitating test and lymphocyte proliferative response was positive for an extract of D. Hansenii, providing evidence to incriminate this fungus. This is the first described case of EAA caused by D. Hansenii. PMID:12449192

2002-11-01

158

Assessment of periodic sub-diurnal Earth rotation variations at tidal frequencies through transformation of VLBI normal equation systems  

British Library Electronic Table of Contents (United Kingdom)

We present an empirical model for periodic variations of diurnal and sub-diurnal Earth rotation parameters (ERPs) that was derived based on the transformation of normal equation (NEQ) systems of Very Long Baseline Interferometry (VLBI) observing sessions. NEQ systems that contain highly resolved polar motion and UT1-TAI with a temporal resolution of 15?min were generated and then transformed to the coefficients of the tidal ERP model to be solved for. To investigate the quality of this model, comparisons with empirical models from the Global Positioning System (GPS), another VLBI model and the model adopted by the conventions of the International Earth Rotation and Reference Systems Service (IERS) were performed. The absolute coefficients of these models agree almost completely within 7.5?...

2011-01-01

159

Three-dimensional evaluation of cartilage thickness and cartilage volume in the knee joint with MR imaging: reproducibility in volunteers; Dreidimensionale Dicken- und Volumenbestimmung des Kniegelenkknorpels mit der MRT: Reproduzierbarkeit am Probanden  

Energy Technology Data Exchange (ETDEWEB)

Objective: To determine the reproductibility of three-dimensional volume and thickness measurements of the knee joint cartilage with MRI in volunteers. Methods: The knees of 7 healthy individuals (ages 23 to 58 yrs.) were sagitally imaged with a resolution of 2x0.31x0.31 mm{sup 3}, using a fat-suppressed FLASH-3 D sequence. The knee was repositioned in between replicate acquisitions, 6 data sets being obtained in each case. After semiautomatic segmentation and three-dimensional reconstruction of the cartilage, the thickness was determined independent of the original section orientation. The coefficient of variation for repeated volume measurements and the deviations of the maximal cartilage thickness values were calculated subsequently. Results: The mean variation of the cartilage volumes of the replicate measurements was 1.4% ({+-}0.8%) in the patella, 1.7% ({+-}1.5%) in the femur, 3.0% ({+-}1.2%) in the medial tibial ...

1997-12-01

160

Microrheological Studies of Regenerated Silk Fibroin Solution by Video Microscopy  

CERN Document Server

We have carried out studies on the rheological properties of regenerated silk fibroin (RSF) solution using video microscopy. The degummed silk from the Bombyx mori silkworm was used to prepare RSF solution by dissolving it in calcium nitrate tetrahydrate-methanol solvent. Measurements were carried out by tracking the position of an embedded micron-sized polystyrene bead within the RSF solution through video imaging. The time dependent mean squared displacement (MSD) of the bead in solution and hence, the complex shear modulus of this solution was calculated from the bead's position information. An optical tweezer was used to transport and locate the bead at any desired site within the micro-volume of the sample, to facilitate the subsequent free-bead video analysis. We present here the results of rheological measurements of the silk polymer network in solution over a frequency range, whose upper limit is the frame capture rate of our camera, at ...

2007-01-01

161

Land Cover Classification Comparison with Different Resolution ...  

Science.gov (United States)

Dec 9, 2005 ... Classification of high resolution imagery is not as straightforward as more ... The challenges of classifying high resolution imagery stems ...

162

The effects of a hydrogen pair in the electronic structure of the FCC iron containing a vacancy  

Energy Technology Data Exchange (ETDEWEB)

Fuel cell vehicles have been identified as the personal transportation technology of the future because of their high efficiency and very low emissions. To achieve the goal of road-ready fuel cell vehicles, great strides must be made in the development of fuel cells, hydrogen production and hydrogen storage technologies, that includes metal-H interaction studies and safety considerations. The interaction between two-hydrogen atoms and a {gamma}-Fe structure containing a vacancy has been studied using a cluster model and a theoretical method. For the study of the sequential absorption, the hydrogen atoms were positioned in their energy minima configurations, near the vacancy. The interactions mainly involve Fe 4s-H 1s atomic orbitals. The contribution of Fe 4p and Fe 3d orbitals is much less important. The Fe-Fe bond is weakened as new Fe-H-H and H-H pairs were formed. The effect of H atoms is limited to its first Fe ...

2010-06-15

163

Spiral Structures and Shocks in Accretion Discs in Close Binary Systems: the Role of the Injection Velocity at the Inner Lagrangian Point  

Science.gov (United States)

In our previous paper (Lanzafame et al. 2000, PASJ 52, 515) we showed, through 2D SPH simulations, that the stellar mass ratio, M 2 / M 1, of a close binary system (that determines the position and then the initial specific angular momentum at L 1) plays a fundamental role in the formation and development of spiral structures and shock fronts in the radial flow of accretion discs. In that work only a quasi-sonic value of the injection velocity at L 1 was considered. In the present work we also carried out 2D SPH simulations with the aim to investigate the development of such structures, while keeping constant the mass of the compact primary (M 1 = 1 M odot) and the separation between the two components, and assuming as an initial condition of two different supersonic injection velocities at L 1, characterizing two sets of simulations. For each set we considered four values of the secondary to primary mass ratio, M 2 / M 1. We worked out 2D models because the ...

2001-02-01

164

Magnetic properties and low temperature X-ray studies of the weak ferromagnetic monoclinic and trigonal chromium tellurides Cr_5Te_8  

International Nuclear Information System (INIS)

Monoclinic and trigonal Cr_5Te_8 show a transition into the ferromagnetic state with a Curie temperature T_c, which sensitively depends on the actual composition. Monoclinic samples exhibit a lower T_c despite their higher Cr content. This observation is explained on the basis of less effective ferromagnetic superexchange in the monoclinic compounds and the larger number of Cr atoms being antiferromagnetically coupled. Magnetization experiments performed at 5 K demonstrate that the compounds saturate already at rather low magnetic fields. In addition, small values are estimated for the coercitive field H_c as well as for the remanence magnetization both being typical for weak ferromagnetic materials. The values for the saturation magnetization amount to about 72% and 65% for monoclinic and trigonal Cr_5Te_8, respectively. These low values can partially be explained on the basis of antiferromagnetically coupled Cr(III) d"3 centers. An additional spin canting is assumed to fully account ...

2004-03-01

165

High-temperature ferromagnetism in laser-deposited layers of silicon and germanium doped with manganese or iron impurities  

Energy Technology Data Exchange (ETDEWEB)

The paper reports on the results of a study of the synthesis conditions effects on magnetic and transport properties of nanosized layers of high-T{sub c} diluted magnetic semiconductors (DMS), such as Ge:Mn, Si:Mn and Si:Fe, fabricated by laser-plasma deposition over a wide range of the growth temperature, T{sub g}=(20-550) deg. C on single-crystal GaAs or Al{sub 2}O{sub 3} substrates. Ferromagnetism of the layers was detected by measurement data of the magneto-optical Kerr effect, anomalous Hall effect, negative magnetoresistance and ferromagnetic resonance (FMR) at 5-500 K. The optimum growth temperature, T{sub g}, for Si:Mn/GaAs layers with T{sub c}{approx}400 K is shown to be about 400 deg. C. The Si:Mn/Al{sub 2}O{sub 3} layers with 35% of Mn have the metal-type of conductivity with manifestation of magnetization up to room temperature. Different types of uniformly doped structures and digital alloys have been investigated. In contrast to GaSb:Mn films, Si-based ferromagnetic ...

2009-04-15

166

Ground and excited state absorption of Ni{sup 2+} ions in MgAl{sub 2}O{sub 4}: Crystal field analysis  

Energy Technology Data Exchange (ETDEWEB)

The exchange charge model (ECM) of crystal field is utilized to provide the theoretical explanation of the ground state absorption and the excited state absorption observed for the octahedrally coordinated Ni{sup 2+} ions in the spinel MgAl{sub 2}O{sub 4}. The ECM enables modeling of the crystal field parameters (CFPs) for the impurity ions based on the crystal structure data of the host lattice. To ensure the reliability of the CFPs, the convergence of the CFP values with the increasing number of the coordination spheres taken into account in the ECM calculations is considered. The trigonal CFPs B{sub 2}{sup 0},B{sub 4}{sup 0}andB{sub 4}{sup -3} determined by the ECM, together with the appropriate Racah parameters B and C, serve as input to two crystal field analysis computer packages, which compute the energy level schemes within the whole 3d{sup 8} configuration. The cubic approximation utilizing only one CFP Dq is also discussed. Basic ...

2007-04-25

167

Depth migration in transversely isotropic media with explicit operators  

Energy Technology Data Exchange (ETDEWEB)

The author presents and analyzes three approaches to calculating explicit two-dimensional (2D) depth-extrapolation filters for all propagation modes (P, SV, and SH) in transversely isotropic media with vertical and tilted axis of symmetry. These extrapolation filters are used to do 2D poststack depth migration, and also, just as for isotropic media, these 2D filters are used in the McClellan transformation to do poststack 3D depth migration. Furthermore, the same explicit filters can also be used to do depth-extrapolation of prestack data. The explicit filters are derived by generalizations of three different approaches: the modified Taylor series, least-squares, and minimax methods initially developed for isotropic media. The examples here show that the least-squares and minimax methods produce filters with accurate extrapolation (measured in the ability to position steep reflectors) for a wider range of propagation angles ...

1994-12-01

168

Basic study of entire whole-body PET scanners based on the OpenPET geometry  

International Nuclear Information System (INIS)

A conventional PET scanner has a 15-25 cm axial field-of-view (FOV) and images a whole body using about six bed positions. An OpenPET geometry can extend the axial FOV with a limited number of detectors. The entire whole-body PET scanner must be able to process a large amount of data effectively. In this work, we study feasibility of the fully 3D entire whole-body PET scanner using the GATE simulation. The OpenPET has 12 block detector rings with the ring diameter of 840 mm and each block detector ring consists of 48 depth-of-interaction (DOI) detectors. The OpenPET has the axial length of 895.95 mm with five parts of 58.95 mm open gaps. The OpenPET has higher single data loss than a conventional PET scanner at grouping circuits. NECR of the OpenPET decreases by single data loss. But single data loss is mitigated by separating the axially arranged detector into two parts. Also, multiple coincidences are found to be ...

2010-09-01

169

A study of image-guided radiotherapy of bladder cancer based on lipiodol injection in the bladder wall  

Energy Technology Data Exchange (ETDEWEB)

Purpose. We have tested a procedure of focal injection of the contrast medium Lipiodol as a fiducial marker for image-guided boost of the tumor in bladder cancer radiotherapy (RT). In this study, we have evaluated the feasibility and the safety of the method as well as the inter- and intra-fraction shift of the bladder tumor. Materials and methods. Five patients with muscle invasive urinary bladder cancer were included in the study. Lipiodol was injected during flexible cystoscopy into the submucosa of the bladder wall at the periphery of the tumor or the post resection tumor-bed. Cone-beam CT (CBCT) scans were acquired daily throughout the course of RT. Results. Lipiodol demarcation of the bladder tumor was feasible and safe with only a minimum of side effects related to the procedure. The Lipiodol spots were visible on CT and CBCT scans for the duration of the RT course. More than half of all the treatment fractions required a geometric shift of 5 mm or more to match on the Lipiodol ...

2010-10-15

170

Method and system for determining depth distribution of radiation-emitting material located in a source medium and radiation detector system for use therein  

Energy Technology Data Exchange (ETDEWEB)

A method, system and a radiation detector system for use therein are provided for determining the depth distribution of radiation-emitting material distributed in a source medium, such as a contaminated field, without the need to take samples, such as extensive soil samples, to determine the depth distribution. The system includes a portable detector assembly with an x-ray or gamma-ray detector having a detector axis for detecting the emitted radiation. The radiation may be naturally-emitted by the material, such as gamma-ray-emitting radionuclides, or emitted when the material is struck by other radiation. The assembly also includes a hollow collimator in which the detector is positioned. The collimator causes the emitted radiation to bend toward the detector as rays parallel to the detector axis of the detector. The collimator may be a hollow cylinder positioned so that its central axis is perpendicular to the upper surface of the large area ...

2003-03-04

171

Transplantation of engineered bone tissue using a rotary three-dimensional culture system.  

Science.gov (United States)

Bone is a complex, highly structured, mechanically active, three-dimensional (3-D) tissue composed of cellular and matrix elements. We previously published a report on in situ collagen gelation using a rotary 3-D culture system (CG-RC system) for the construction of large tissue specimens. The objective of the current study was to evaluate the feasibility of bone tissue engineering using our CG-RC system. Osteoblasts from the calvaria of newborn Wistar rats were cultured in the CG-RC system for up to 3 wk. The engineered 3-D tissues were implanted into the backs of nude mice and calvarial round bone defects in Wistar rats. Cell metabolic activity, mineralization, and bone-related proteins were measured in vitro in the engineered 3-D tissues. Also, the in vivo histological features of the transplanted, engineered ...

2007-03-11

172

Topological excitations and second order transitions in 3D O(N) models  

Energy Technology Data Exchange (ETDEWEB)

I discuss several examples of critical phenomena in O(N) models where topological excitations play an important role at criticality. I focus particular attention on the O(2) model in 3D, where recent measurements of the vortex string length distribution in equilibrium suggest the existence of a quantitative picture of the critical behavior in terms of defects. The compatibility of this perspective with renormalization group predictions is examined.

2001-01-01

173

T-HEMP3D, 3-D Time-Dependent Elastic Plastic Flow  

International Nuclear Information System (INIS)

1 - Description of program or function: T-HEMP3D (Transportable HEMP3D) is a derivative of the STEALTH three-dimensional thermodynamics code developed by Science Applications, Inc. Changes were made primarily in three areas: material specification, coordinate generation, and the addition of sliding surface boundary conditions. STEALTH itself is based entirely on the HEMP3D code written at LLNL. HEMP3D solves problems in solid mechanics involving dynamic plasticity and time-dependent material behavior and problems in gas dynamics. 2 - Method of solution: The equations of motion, conservation equations, and constitutive relations for stresses, strains, hydrostatic pressure, the von Mises yield condition, and artificial viscosity are solved by finite difference methods following the format of the HEMP code (NESC Abstract ...

174

Sequence specificity of the non-natural pyrido[2,3-d]pyrimidine nucleoside in triple helix formation.  

UK PubMed Central (United Kingdom)

The non-natural pyrido[2,3-d]pyrimidine nucleoside F, which pairs preferentially with guanine (G) and adenine (A) within double-helical DNA, recognizes with high selectivity AT base pairs within triple-helical...Full Text Available

1994-07-11

175

Pd-Na/F double exploding foil photoionization experiment  

Science.gov (United States)

The achievement of inner-shell photoionization of Zn-like Pd by means of two exploding foils is described. This resulted in the soft X-ray transition 3d94s2-3d104p at 46 A. It is shown that the photoionization of inner shell electrons in highly stripped ions can lead to X-ray transitions which may be candidates for X-ray lasers under 50 A.

1990-03-01

176

K_#beta#/K_#alpha# X-Ray Intensity Ratio Studies on the Valence Electronic States of 3d-Transition Metals in some of their Compounds  

International Nuclear Information System (INIS)

Our studies on K#beta#/K#alpha# X-ray intensity ratios of some of the technologically important 3d-transition metal compounds have been reviewed. Comparison of the experimental results with single-configuration Dirac-Fock calculations provided important information on the valence states of the transition metals in various compounds, which can be helpful in understanding the nature of bonding in the compounds. (author)

2000-02-01

177

Chemical sensitivity of the Ksub(. beta. )/Ksub(. cap alpha. ) x-ray intensity ratio for 3d elements  

Energy Technology Data Exchange (ETDEWEB)

Chemical influences on the relative Ksub(..beta..)/Ksub(..cap alpha..) x-ray intensity ratio up to five per cent were found for different chemical constitutions of Cr, Mn, Fe and Cu by very precise PIXE measurements. In the discussion of these effects, screening of 3p electrons by a varying 3d valence charge, as well as polarizational effects are of importance.

1982-12-28

178

Chemical sensitivity of the Ksub(#nu#)/Ksub(#alpha#) x-ray intensity ratio for 3d elements  

International Nuclear Information System (INIS)

Chemical influences on the relative Ksub(#nu#)/Ksub(#alpha#) x-ray intensity ratio up to five per cent were found for different chemical constitutions of Cr, Mn, Fe and Cu by very precise PIXE measurements. In the discussion of these effects, screening of 3p electrons by a varying 3d valence charge, as well as polarisational effects are of importance. (author).

1982-12-01

179

Chapter 14: Seismic imaging using 2- and 3-D migration  

Energy Technology Data Exchange (ETDEWEB)

Development of a number of original 3-D migration methods and algorithms is described. The computational efficiency of these algorithms is demonstrated by implementing them on vector and parallel supercomputers. Two-dimensional post-stack and pre-stack depth migration algorithms in the frequency - space domain using implicit finite difference method were also developed and implemented on a parallel computer, and adapted for applications that range from deep crustal imaging of seismic wavefields that involve wide ranging travel times and frequencies. All implicit finite difference migration algorithms were highly prallelized . The one pass 3-D post-stack depth migration algorithm was extensively used for imaging of seismic monitoring data from Cold Lake, Alberta. Experience shows that it provides the right trade-off between accuracy and computational efficiency. A new formulation of the ...

1999-09-01

180

Amplification of Inaccuracies of Initial Conditions in Cosmological Simulations  

Science.gov (United States)

Cosmological N-body and hydrodynamic simulations start with a realization of a random density fluctuation field representing a cosmological model at an early epoch. The density field is often replaced by a set of particles whose positions and velocities are set to conform to the desired density field. Each particle represents a cloud of huge number of real particles. Positions and velocities of particles are subsequently integrated by various numerical codes. We have simulated a set of collisionless collapses of Gaussian density peaks by using the PM and P(3) M codes. We find that in cosmological simulations the physics at scales below the mean particle separation(MPS) is dominated by inaccuracies in describing the initial density field, and cannot be studied even by the high force-resolution codes. Since density fluctuations are ill-defined at scales smaller than MPS, it is desirable not to amplify this problem during the ...

1997-01-01

181

An efficient method for 3-D pre stack migration in time reverse-time depth by using finite difference method; Um metodo eficiente para migracao pre-empilhamento 3-D em profundidade reversa no tempo pelo metodo das diferencas finitas  

Energy Technology Data Exchange (ETDEWEB)

Much of the current technology on 3D-prestack depth migration is based on the Kirchhoff method and the traveltime information needed for this purpose is obtained by the ray-theory approximation. The main motivation driving these options is to reduce computations but it can also have an adverse effect on the quality of results. Experience with real data indicates that the corresponding poststack data migrated by the reverse-time method often yields superior results. Considerable computational efficiency can be obtained by employing nonuniform coarse grid spacing during the reverse-time migration. We followed this strategy for developing a parallel scheme for doing 3D- prestack depth migration. However, we worked only on a small subset of shot gathers whose determined by the Quasi-Monte Carlo method. The results were indistinguishable from those obtained by using a much larger population of uniformly ...

1997-07-01

182

Three-Dimensional Rotational Angiography of the Inferior Vena Cava as an Adjunct to Inferior Vena Cava Filter Retrieval  

International Nuclear Information System (INIS)

The objective of this study was to explore the role of three-dimensional (3-D) rotational angiography (RA) of the inferior vena cava (IVC; 3-D CV) before filter retrieval and its impact on treatment planning compared with standard anteroposterior cavography (sCV). Thirty patients underwent sCV and 3-D CV before IVC filter retrieval. Parameters assessed were: projection of filter arms or legs beyond the caval lumen, thrombus burden within the filter and IVC, and orientation of the filter within IVC. Skin and effective radiation doses were calculated. Statistical analysis was performed using paired Student t test and nonparametric McNemar's test. Standard anteroposterior cavography detected 49 filter arms or legs projecting beyond the caval lumen in 25 patients. Three-dimensional CV demonstrated 89 filter arms or legs projecting beyond the caval lumen in 28 ...

2009-01-01

183

Characterisation of thin films on rough steel substrates by FTIR microscopy and imaging  

International Nuclear Information System (INIS)

Complete text of publication follows. According to the new European regulations (Restrictions of Hazardous Substance Directive), there is an emerging demand for environmental friendly metal treatments instead on formerly used chromate conversion coating technique. The aim of the present investigations was to characterise and compare silicon containing protective thin layers on roughened galvanized steel surfaces (with average roughness of 0.7 microns), using FTIR microscopy and imaging techniques. The silicon containing coatings were produced either by Chemical Vapour Deposition (CVD) or by wet chemical treatment using liquid silane. FTIR techniques offer new possibilities in the characterisations and chemical mapping of differently coated thin films, besides SEM+EDS, AFM, nanoindentation, XPS measurements (P. Nemeth et al., Materials Science Forum, 589 (2008) 433-438). All measurements were carried out by a Varian FTS-7000 spectrometer with a 'Stingray' microscope configuration ...

184

Radiation damage measurements in room temperature semiconductor radiation detectors  

Energy Technology Data Exchange (ETDEWEB)

The literature of radiation damage measurements on cadmium zinc telluride (CZT), cadmium telluride (CT), and mercuric iodide (HgI{sub 2}) is reviewed and in the case of CZT supplemented by new alpha particle data. CZT strip detectors exposed to intermediate energy (1.3 MeV) proton fluences exhibit increased interstrip leakage after 10{sup 10} p/cm{sup 2} and significant bulk leakage after 10{sup 12} p/cm{sup 2}. CZT exposed to 200 MeV protons shows a two-fold loss in energy resolution after a fluence of 5 {times} 10{sup 9} p/cm{sup 2} in thick (3 mm) planar devices but little effect in 2 mm devices. No energy resolution effects were noted from moderated fission spectrum of neutrons after fluences up to 10{sup 10} n/cm{sup 2}, although activation was evident. Exposures of CZT to 5 MeV alpha particle at fluences up to 1.5 {times} 10{sup 10} {alpha}/cm{sup 2} produced a near linear decrease in peak position with fluence and ...

1998-12-01

185

Rn3D: A finite element code for simulating gas flow and radon transport in variably saturated, nonisothermal porous media. User`s manual, Version 1.0  

Energy Technology Data Exchange (ETDEWEB)

This document is a user`s manual for the Rn3D finite element code. Rn3D was developed to simulate gas flow and radon transport in variably saturated, nonisothermal porous media. The Rn3D model is applicable to a wide range of problems involving radon transport in soil because it can simulate either steady-state or transient flow and transport in one-, two- or three-dimensions (including radially symmetric two-dimensional problems). The porous materials may be heterogeneous and anisotropic. This manual describes all pertinent mathematics related to the governing, boundary, and constitutive equations of the model, as well as the development of the finite element equations used in the code. Instructions are given for constructing Rn3D input files and executing the code, as well as a description of all output files generated ...

1994-01-01

186

A 3-D hydrodynamic dispersion model for modeling tracer transport in Geothermal Reservoirs  

International Nuclear Information System (INIS)

A 3-D hydrodynamic dispersion model for tracer transport is developed and implemented into the TOUGH2 EOS3 (T2R3D) module. The model formulation incorporates a full dispersion tensor, based on a 3-D velocity field with a 3-D, irregular grid in a heterogeneous geological system. Two different weighting schemes are proposed for spatial average of 3-D velocity fields and concentration gradients to evaluate the mass flux by dispersion and diffusion of a tracer or a radionuclide. This new module of the TOUGH2 code is designed to simulate processes of tracer/radionuclide transport using an irregular, 3-D integral finite difference grid in non-isothermal, three-dimensional, multiphase, porous/fractured subsurface systems. The numerical method ...

187

3D time-of-flight MR angiography of the intracranial vessels: optimization of the technique with water excitation, parallel acquisition, eight-channel phased-array head coil and low-dose contrast administration  

Energy Technology Data Exchange (ETDEWEB)

The aim of this study is three folds: to compare the eight-channel phased-array and standard circularly polarized (CP) head coils in visualiazation of the intracranial vessels, to compare the three-dimentional (3D) time-of-flight (TOF) MR angiography (MRA) techniques, and to define the effects of parallel imaging in 3D TOF MRA. Fifteen healthy volunteers underwent 3D TOF MRA of the intracranial vessels using eight-channel phased-array and CP standard head coils. The following MRA techniques were obtained on each volunteer: (1) conventional 3D TOF MRA with magnetization transfer; (2) 3D TOF MRA with water excitation for background suppression; and (3) low-dose (0.5 ml) gadolinium-enhanced 3D TOF MRA with water excitation. Results are ...

2004-11-01

188

The role of 3D Helical CT in the reconstructive treatment of maxillofacial cancers  

International Nuclear Information System (INIS)

Purpose of this work is to investigate the role of Helical CT and the usefulness of three-dimensional (3D) imaging for pre-operative planning and follow-up of reconstructive maxillofacial surgery with alloplastic material in neoplastic disease involving this region. From 1996 to 1999 eleven patients were examined with Helical CT and 3D images for planning of maxillofacial plastic and reconstructive surgery for advanced cancer of this anatomically complex region. A 3D-modulated titanium mesh (100%) or micro nets was used to rebuild the anterior surface of maxillary bone and the orbital floor. The mesh was cut to the appropriate size and shape and curved where necessary. Within the residual sinusal cavity a siliconed filling was used surmounting an acrylic prosthesis with dental arch to rebuild the palate. A rehydrated bovine pericardium was affixed and moduled on ...

2000-12-01

189

Synthesis of 4,5,6,7 and 2,4,5,6,7 deuterium-labeled indole-3-acetic acid for use in mass spectrometric assays  

Energy Technology Data Exchange (ETDEWEB)

Syntheses are described for tetra and pentadeutero indole-3-acetic acid (IAA) labeled in positions 4,5,6,7 or 2,4,5,6,7 of the indole moiety. Polydeuterated IAA is proposed as an internal standard for gas chromatographic-mass spectrometric analysis of IAA by selected ion monitoring. Nanogram amounts of IAA may be assayed by monitoring the base peak of IAA at m/z = 130 (134 for d/sub 4/-IAA) and the molecular ion of the methyl ester of IAA at 189 (193 for d/sub 4/-IAA). Deuterium in positions 4,5,6, and 7 and, to only a slightly lesser extent, that in position 2 of IAA is retained during alkali treatment, thus permitting use of these compounds as internal standards for assay of IAA released by alkaline hydrolysis of ester and amide conjugates. The use of polydeutero internal standards separates the standards from the isotope cluster caused by the normal abundance of heavy isotopes and also permits use of reduced mass ...

1980-10-01

190

Surface-loss power calculations for the LANSCE DTL  

Energy Technology Data Exchange (ETDEWEB)

The surface losses in the drift-tube linac (DTL) tanks 3 and 4 of the LANSCE linear accelerator are calculated using 3-D electromagnetic modeling with the CST MicroWave Studio (MWS). The results are used to provide more realistic power estimates for the 201.25MHz RF upgrade design within the LANSCE-R project. We compared 3-D MWS results with those from traditional 2-D Superfish computations for DTL cells and their simplified models and found differences on the level of a few percent. The differences are traced to a 3-D effect consisting in a redistribution of the surface currents on the drift tubes (DT) produced by the DT stem. The dependence of MWS results on the mesh size used in computations is also discussed.

2008-01-01

191

Importance of preoperative imaging with 64-row three-dimensional multidetector computed tomography for safer video-assisted thoracic surgery in lung cancer  

British Library Electronic Table of Contents (United Kingdom)

Purpose Video-assisted thoracic surgery (VATS) has recently been adopted for complicated anatomical lung resections. During these thoracoscopic procedures, surgeons view the operative field on a two-dimensional (2-D) video monitor and cannot palpate the organ directly, thus frequently encountering anatomical difficulties. This study aimed to estimate the usefulness of preoperative three-dimensional (3-D) imaging of thoracic organs. Methods We compared the preoperative 64-row three-dimensional multidetector computed tomography (3DMDCT) findings of lung cancer-affected thoracic organs to the operative findings. Results In comparison to the operative findings, the branches of pulmonary arteries, veins, and bronchi were well defined in the 3D-MDCT images of 27 patients. Conclusion 3D-MDCT imag...

2009-01-01

192

First trimester measurements of nasal bone length using three-dimensional ultrasound  

British Library Electronic Table of Contents (United Kingdom)

Objectives To investigate the feasibility and reproducibility of measurements of nasal bone length using a three-dimensional (3D) ultrasound in the first trimester. Methods In a prospective study, 118 consecutive pregnant women attending for Down syndrome screening at 11-13 + 6 weeks were recruited. They had successful fetal nasal bone measurement by two-dimensional (2D) ultrasound by four operators. Three-dimensional volumes were recorded in the mid-sagittal plane of fetal profile by the fifth operator and examined using multiplanar techniques. Another independent investigator randomly compared his measurements with one of the four operators. Results In the subsequent 3D examination, the nasal bone length could be examined in 94 cases (79.7%). The mean difference between the 2D and 3D mea...

2009-01-01

193

3D modelling as a support to thermal-hydraulic safety analyses with standard codes  

Energy Technology Data Exchange (ETDEWEB)

A three-dimensional (3D) thermal-hydraulic model and a numerical procedure for the simulation and analysis of a steady-state, as well as transient operation of nuclear power plant components are presented. A two-fluid approach is applied to modelling of two-phase flow. Thermal-hydraulics of a horizontal steam generator in the WWER 1000 nuclear power plant has been simulated at the full load, steady-state operation. A comparison of the numerical results with data measured at the NPP Novovoronjezh shows good agreement. 3D numerical results can be used in plant design or retrofitting, in nuclear power plant operation and safety analysis and as improvement of existing one-dimensional thermal-hydraulics models of the horizontal steam generator which are assessed by system codes used for the nuclear power plant safety analyses. (author)

1999-07-01

194

3D modelling as a support to thermal-hydraulic safety analyses with standard codes  

International Nuclear Information System (INIS)

A three-dimensional (3D) thermal-hydraulic model and a numerical procedure for the simulation and analysis of a steady-state, as well as transient operation of nuclear power plant components are presented. A two-fluid approach is applied to modelling of two-phase flow. Thermal-hydraulics of a horizontal steam generator in the WWER 1000 nuclear power plant has been simulated at the full load, steady-state operation. A comparison of the numerical results with data measured at the NPP Novovoronjezh shows good agreement. 3D numerical results can be used in plant design or retrofitting, in nuclear power plant operation and safety analysis and as improvement of existing one-dimensional thermal-hydraulics models of the horizontal steam generator which are assessed by system codes used for the nuclear power plant safety analyses. (author)

1999-04-19

195

3D model for a secondary facultative pond  

British Library Electronic Table of Contents (United Kingdom)

This paper describes a comprehensive model of wastewater treatment in secondary facultative ponds, which combines 3D hydrodynamics with a mechanistic water quality model. The hydrodynamics are based on the Navier-Stokes equation for incompressible fluids under shallow water and Boussinesq assumptions capturing the flow dynamics along length, breadth and depth of the pond. The water quality sub model is based on the Activated Sludge Model (ASM) concept, describing COD and nutrient removal as function of bacterial growth following Monod kinetics, except for Escherichia coli removal, which was modelled as first order decay. The model was implemented in the Delft3D software and was used to evaluate the effect of wind and the addition of baffles on the water flow pattern, temperature profiles i...

2011-01-01

196

A stochastic convolution/superposition method with isocenter sampling to evaluate intrafraction motion effects in IMRT  

International Nuclear Information System (INIS)

Current methods to calculate dose distributions with organ motion can be broadly classified as 'dose convolution' and 'fluence convolution' methods. In the former, a static dose distribution is convolved with the probability distribution function (PDF) that characterizes the motion. However, artifacts are produced near the surface and around inhomogeneities because the method assumes shift invariance. Fluence convolution avoids these artifacts by convolving the PDF with the incident fluence instead of the patient dose. In this paper we present an alternative method that improves the accuracy, generality as well as the speed of dose calculation with organ motion. The algorithm starts by sampling an isocenter point from a parametrically defined space curve corresponding to the patient-specific motion trajectory. Then a photon is sampled in the linac head and propagated through the three-dimensional (3-D) collimator structure corresponding to a ...

2005-04-01

197

Test Cases - CFL3D - NASA  

Science.gov (United States)

Jun 10, 2011 ... Subsonic flow past a semi-infinite flat plate is modeled at Reynolds number 6 ..... data is taken from Cook, McDonald, and Firmin, AGARD-AR-138, 1979, p. ...... too large a time-averaged separation bubble behind the hump. ...

198

Statistical properties of nucleotide clusters in DNA sequences*  

UK PubMed Central (United Kingdom)

Using the complete genome of Plasmodium falciparum 3D7 which has 14 chromosomes as an example, we have examined the distribution functions for the amount of C or G and A or T consecutively...Full Text Available

2005-05-01

199

Robust principal axes determination for point-based shapes using least median of squares  

UK PubMed Central (United Kingdom)

A robust technique for determining the principal axes of a 3D shape represented by a point set, possibly with noise, is presented. We use techniques from robust statistics to guide the classical...Full Text Available

2009-04-01

200

Phase separation, pore structure, and properties of nanofibrous gelatin scaffolds  

UK PubMed Central (United Kingdom)

The development of three-dimensional (3D) biomimetic scaffolds which provide an optimal environment for cells adhesion, proliferation and differentiation, and guide new tissue formation has...Full Text Available

2009-09-01

201

Particle Swarm Optimization: An efficient method for tracing periodic orbits in 3D galactic potentials  

CERN Document Server

We propose the Particle Swarm Optimization (PSO) as an alternative method for locating periodic orbits in a three--dimensional (3D) model of barred galaxies. We develop an appropriate scheme that transforms the problem of finding periodic orbits into the problem of detecting global minimizers of a function, which is defined on the Poincar\\'{e} Surface of Section (PSS) of the Hamiltonian system. By combining the PSO method with deflection techniques, we succeeded in tracing systematically several periodic orbits of the system. The method succeeded in tracing the initial conditions of periodic orbits in cases where Newton iterative techniques had difficulties. In particular, we found families of 2D and 3D periodic orbits associated with the inner 8:1 to 12:1 resonances, between the radial 4:1 and corotation resonances of our 3D Ferrers bar model. The main ...

2005-01-01

202

PRISM 3D: Global Warming Analysis  

Science.gov (United States)

Estimates of global warming during the mid-Piacenzian Age of the Pliocene Epoch suggest temperatures were 2 degrees C greater than today. ... million years approaches this level of warming. PRISM/Global Warmin...

203

Natural Gaits of the Non-Pathological Flat Foot and High-Arched Foot  

UK PubMed Central (United Kingdom)

There has been a controversy as to whether or not the non-pathological flat foot and high-arched foot have an effect on human walking activities. The 3D foot scanning system was employed to obtain static...Full Text Available

204

Modelling the masticatory biomechanics of a pig  

UK PubMed Central (United Kingdom)

The relationships between muscle tensions, jaw motions, bite and joint forces, and craniofacial morphology are not fully understood. Three-dimensional (3-D) computer models are able to combine anatomical...Full Text Available

2002-11-01

205

Metacad programmer's guide  

Energy Technology Data Exchange (ETDEWEB)

Metacad is a collection of routines which creates a randomly accessible data structure from Applicon's APPLE-3D data format and supplies a logical method for manipulation of the data structure by a CAD application program.

1983-05-01

206

Lockheed WP-3D Orion  

Science.gov (United States)

Approximately 62,000 lbs Fuel Load: 58,000 lbs. Type Fuel: JP4, JP5, JP8, JET A, JET A-1, JET B Standard Fuel Burn: 4500 - 6000 lbs/hr depending on altitude and airspeed Maximum...

2011-08-17

207

Heat transfer augmentation in 3D internally finned and microfinned helical tube  

Energy Technology Data Exchange (ETDEWEB)

Experiments are performed to investigate the single-phase flow and flow-boiling heat transfer augmentation in 3D internally finned and micro-finned helical tubes. The tests for single-phase flow heat transfer augmentation are carried out in helical tubes with a curvature of 0.0663 and a length of 1.15 m, and the examined range of the Reynolds number varies from 1000 to 8500. Within the applied range of Reynolds number, compared with the smooth helical tube, the average heat transfer augmentation ratio for the two finned tubes is 71% and 103%, but associated with a flow resistance increase of 90% and 140%, respectively. A higher fin height gives a higher heat transfer rate and a larger friction flow resistance. The tests for flow-boiling heat transfer are carried out in 3D internally micro-finned helical tube with a curvature of 0.0605 and a length of 0.668 m. Compared with that in the smooth helical ...

2005-05-01

208

Evaluation of tilted cone-beam CT orbits in the development of a dedicated hybrid mammotomograph  

UK PubMed Central (United Kingdom)

A compact dedicated 3D breast SPECT-CT (mammotomography) system is currently under development. In its initial prototype, the cone-beam CT sub-system is restricted to a fixed-tilt circular rotation...Full Text Available

2009-06-21

209

Evaluation of fetal brain development by magnetic resonance imaging. Subependymal germinal matrix layer and cerebral ventricle  

International Nuclear Information System (INIS)

Three dimensional data of brain from the formalin-fixed fetuses were collected without isolation, by the 4.7 tesla super high magnetic field MRI and the developmental process of the cerebral parenchyma was studied by 3D images. Subjects were 13 fetal brain and MRI was performed using 3D-steady-state free precession sequence. The isolated brain is very soft and fragile and is deformed by its weight at the imaging. However 3D-MRI can be obtained without isolation, and the deformation is remarkably small. The subependymal germinal matrix layer did not be observed in 7 weeks-old fetus, appeared at 9 weeks-old and increased gradually. Then it rapidly reduced from 28 weeks-old. The volume calculated, from 3D-MRI, increased rapidly from 9 weeks-old to 23 weeks-old, and reached the maximum (2.346 mm"3) at 23 weeks-old. The ...

1999-10-01

210

Electrospray deposition and direct patterning of polylactic acid nanofibrous microcapsules for tissue engineering.  

Science.gov (United States)

Electrospun nanofibers composed of biodegradable polymers are attractive candidates for cell culture scaffolds in tissue engineering. Their fine-meshed structures, resembling natural extracellular matrices, effectively interact with cell surfaces and promote cell proliferation. The application of electrospinning, however, is limited to two-dimensional (2D) or single tube-like scaffolds, and the fabrication of arbitrary three-dimensional (3D) scaffolds from electrospun nanofibers is still very difficult due to the fibers' continuous and entangled form. To address this issue, in this paper, we describe the use of phase-separation-assisted electrospray and electrostatic focusing to perform continuous direct 3D patterning of nanofibrous microcapsules of biodegradable polylactic acid (PLA). These microcapsules exhibit fiber-particle duality because they are composed of nanofibers suitable for cell attachment ...

2011-09-01

211

Computational study of jet interaction flow field with and without incidence  

International Nuclear Information System (INIS)

The objective was to study the interaction of a side jet with the incoming supersonic flow and hypersonic flow. Qualitatively same Cp trends have been obtained as found experimentally. Also in aerodynamic coefficients side jet interaction results in additional pitching moment which is because of the high pressure region in upstream of the jet and a low pressure region in the downstream of the jet. Also jet interaction results in the rise in the lift coefficient. Whereas in the incidence case, simulation has been performed for the hypersonic flows over a biconic body with supersonic lateral jet at Mach 9.7 and incidence of 0"o to incidence of -12"o and 12"o. The results obtained were compared with the experimental and CFD code CFL3D results. PAK-3D over predicts the surface pressure as compared to the CFL3D and experimental results, whereas the qualitative trends ...

2004-05-09

212

Characterization of 3D thermal neutron semiconductor detectors  

International Nuclear Information System (INIS)

Neutron semiconductor detectors for neutron counting and neutron radiography have an increasing importance. Simple silicon neutron detectors are combination of a planar diode with a layer of an appropriate neutron converter such as 6LiF. These devices have limited detection efficiency of not more than 5%. The detection efficiency can be increased by creating a 3D microstructure of dips, trenches or pores in the detector and filling it with a neutron converter. The first results related to the development of such devices are presented. Silicon detectors were fabricated with pyramidal dips on the surface covered with 6LiF and then irradiated by thermal neutrons. Pulse height spectra of the energy deposited in the sensitive volume were compared with simulations. The detection efficiency of these devices was about 6.3%. Samples with different column sizes were fabricated to study the electrical properties of ...

2007-06-11

213

A self-oscillating biophysical computer model of the elongated vocal fold  

UK PubMed Central (United Kingdom)

A new 3D model is developed to simulate the self-oscillation of the elongated vocal folds. This model allows for large deformation and longitudinal displacement. The displacement boundary condition...Full Text Available

2008-01-01

214

3D simulations of microstructure and comparison with experimental microstructure coming from OIM analysis  

International Nuclear Information System (INIS)

This paper presents a new methodology to create realistic 3D microstructures of polycrystals. The virtual microstructures are based on statistical data describing the morphological and crystallographic textures of a sample, obtained from an EBSD analysis. In addition, the methodology can reproduce the observed surface on top of the simulated microstructure. This feature allows finite element calculations on these virtual aggregates to be compared to experimental results of mechanical tests. Such a comparison leads to the identification of the mechanical parameters of constitutive laws, such as critical resolved shear stress and strain hardening, using an optimization algorithm. Two materials were simulated in this study: TiAl and grade 702 zirconium. The first one presents twins inside the microstructure and the second one has an anisotropic texture. Based on 2D simulations, the important parameters necessary to describe a microstructure were ...

215

3D Hepatic Cultures Simultaneously Maintain Primary Hepatocyte and Liver Sinusoidal Endothelial Cell Phenotypes  

UK PubMed Central (United Kingdom)

Developing in vitro engineered hepatic tissues that exhibit stable phenotype is a major challenge in the field of hepatic tissue engineering. However, the rapid dedifferentiation of...Full Text Available

216

Three-dimensional cranio-facial computed tomography  

International Nuclear Information System (INIS)

Computed tomography allows today to reconstruct three-dimensional (eD) images fram axial scans. The authors report their experience in cranio-facial pathology achived in two Departments of Radiology (University of Trieste, Italy and University of Standford, California). 3D images have been realized using two different softwares, one of which allows to reconstruct both soft tissue and bone structures. The application in maxillo-facial traumas, cranio-facial malformations and head tumours are disscussed. 3D images turned out to be very useful for the optimal visualization and for the spatial demostration of the lesion and have potential applications in cranio-facial surgery and radiotherapy.

1986-01-01

217

The relative X-ray intensity Ksub(#alpha#)/Ksub(#beta#) of 3d elements by photoionization and electron capture  

International Nuclear Information System (INIS)

The measurement of K(alpha)/K(beta) X-ray intensity ratio indicates the excitation process and the chemical state of the atom examined. Theoretical considerations on the origin of this property are presented. The difference of these ratios following photoionization and electron capture are calculated by a computer code generating transition matrix elements. The theoretical assumptions involved in the codes are tested by comparing the experimental and calculated data concerning 3d transition element atoms. (D.Gy.).

1981-03-19

218

Spiral CT with three-dimensional and multiplanar reconstruction in the diagnosis of anterior chest wall joint and bone disorders  

Energy Technology Data Exchange (ETDEWEB)

Twenty-seven patients with symptoms or clinical findings suggesting joint or bone disorders of the anterior chest wall (ACW) were evaluated by spiral CT with 3-dimensional (3-D) and multiplanar reconstructions. Preceding conventional ACW tomography was performed in 10 patients. ACW joint and bone changes were visualized more adequately by coronal 2-D reconstructions based on spiral CT than by conventional tomography. In addition, nonossified costal cartilages and soft tissue lesions were demonstrated. 3-D reconstructions sometimes added information, especially in patients with fracture and dislocation. (orig.).

1994-09-01

219

PARALLEL 3-D SPACE CHARGE CALCULATIONS IN THE UNIFIED ACCELERATOR LIBRARY.  

Energy Technology Data Exchange (ETDEWEB)

The paper presents the integration of the SIMBAD space charge module in the UAL framework. SIMBAD is a Particle-in-Cell (PIC) code. Its 3-D Parallel approach features an optimized load balancing scheme based on a genetic algorithm. The UAL framework enhances the SIMBAD standalone version with the interactive ROOT-based analysis environment and an open catalog of accelerator algorithms. The composite package addresses complex high intensity beam dynamics and has been developed as part of the FAIR SIS 100 project.

2006-06-26

220

Development of a motion analysis system using acceleration sensors for tennis and its evaluations  

British Library Electronic Table of Contents (United Kingdom)

The term biological motion is often used by researchers studying the patterns of movement generated by living forms and in sports. We studied a pattern recognition system of motion in sport using biological motion data. Biological motion data are acquired using a 3D motion capture system. However, 3D motion capture systems are very expensive. In this article, a biological motion capture system was built using acceleration sensors. Our proposed system uses the technique of Gaussian fitting and regression analysis. We tested our proposed system in pattern recognition of outdoor tennis and its evaluations.

2011-01-01

221

Comparison of EH with SW-Xsub(alpha) calculations. Electronic structure of 3d, 4d, and 5d metal atom clusters  

Energy Technology Data Exchange (ETDEWEB)

The electronic structure of octahedral metal atom clusters Me/sub 6/ of 3d, 4d, and 5d transition metal atoms (V, Cr; Nb, Mo; Ta, W) has been calculated applying two different quantum-chemical approximation methods (Extended Hueckel (EH) method; SW-Xsub(alpha) method). Equilibrium structures, energy level schemes, Fermi energies and band widths as well as densities of states of clusters are discussed in detail.

1981-01-01

222

Anticonvulsant properties of selected pyrrolo[2,3-d]pyrimidine-2,4-diones and intermediates.  

Science.gov (United States)

A series of pyrrolo[2,3-d]pyrimidine-2,4-diones and intermediates was tested for anticonvulsant activity in mice. Eleven of the 15 compounds possessed anticonvulsant activity against pentylenetetrazol-induced convulsions. One compound afforded more anticonvulsant protection against pentylenetetrazol than did trimethadione (67 and 50%, respectively). A suspension of this compound was found to be as effective as a solution in producing anticonvulsant activity. The results suggest that the nitrile analogs were more potent compared to the carbamyl analog due to higher lipid solubility. PMID:7373552

1980-04-01

223

Time-resolved Fourier transform emission spectroscopy of A2P-X2+ infrared transition of the CN radical  

British Library Electronic Table of Contents (United Kingdom)

The A2P-X2+Dv=-3 bands of the 12C14N radical have been observed by time-resolved Fourier transform spectroscopy in the 1850-3100cm-1 region with a wavenumber resolution of 0.025cm-1. The radical was produced in a pulsed positive column discharge in a cyanogene and helium mixture. Seven bands of v=0-3, 1-4, 2-5, 3-6, 4-7, 5-8, and 6-9 were analyzed to give the molecular constants of each state by least-squares fitting of 801 lines. The pulsed discharge was found to be efficient for production of CN in the excited A2P state. The vibrational excitation temperature was determined to be 6680+-835K and 6757+-534K for the A2P and X2+ states, respectively. The population of the A2P was found to be 4% of that of the X2+ state in the time after turning off the discharge.

2008-01-01

224

The EU as a frontrunner on greenhouse gas emissions trading. How did it happen and will the EU succeed?  

Energy Technology Data Exchange (ETDEWEB)

The objective of this paper is first to provide empirical evidence of what can be seen as a rather remarkable change in EU's position on the use of greenhouse gas (GHG) emissions trading (ET) in climate policy, from the role of a sceptic in the run-up to Kyoto towards more of a frontrunner. The paper argues that there is a synergistic and multilevel mix of explanatory factors for this 'U-turn', including developments at the international, EU, Member State, sub-national, and even down to the personal level. Second, the paper explores and discusses the philosophy behind the Commission's proposal for a directive on GHG ET. Third, the paper examines the prospects for 'success' of a scheme for EU-wide ET using a multifaceted set of metrics. In brief, we argue that output success - the chances for having a directive adopted - hinges on the resolution of two key issues. First, whether the ...

2003-07-01

225

TLD array for precise dose measurements in stereotactic radiation techniques  

International Nuclear Information System (INIS)

We developed a new TLD array for precise dose measurement and verification of the spatial dose distribution in small radiation targets. It consists of a hemicylindrical, tissue-equivalent rod made of polystyrene with 17 parallel moulds for an exact positioning of each TLD. The spatial resolution of the TLD array was evaluated using the Leskell spherical phantom. Dose planning was performed with KULA 4.4 under stereotactic conditions on axial CT images. In the Leksell gamma unit the TLD array was irradiated with a maximal dose of 10 Gy with an unplugged 14 mm collimator. The doses delivered to the TLDs were rechecked by diode detector and film dosimetry and compared to the computer-generated dose profile. We found excellent agreement of our measured values, even at the critical penumbra decline. For the 14 mm and 18 mm collimator and for the 11 mm collimator combination we compared the measured and calculated data at full width at half maximum. ...

1996-12-01

226

SDSS Observations of the Milky Way vs. N-body Models: A Comparison of Stellar Distributions in the Position-Velocity-Metallicity Space  

CERN Document Server

The data obtained by the recent modern sky surveys enable detailed studies of the stellar distribution in the multi-dimensional space spanned by spatial coordinates, velocity and metallicity, from the solar neighborhood all the way out to the outer Milky Way halo. While these results represent exciting observational breakthroughs, their interpretation is not simple. For example, traditional decomposition of the thin and thick disks predicts a strong correlation in metallicity and kinematics at $\\sim$1 kpc from the Galactic plane; however, recent SDSS--based work has demonstrated an absence of this correlation for disk stars. Instead, the variation of the metallicity and rotational velocity distributions can be modeled using non--Gaussian functions that retain their shapes and only shift as the distance from the mid--plane increases. To fully contextualize these recent observational results, a detailed comparison with sophisticated numerical models is necessary. Modern simulations have ...

2008-01-01

227

Real-time neutron radiography at the Iea-R1 m nuclear research reactor  

International Nuclear Information System (INIS)

A LIXI (Light Intensifier X-ray Image) device has been employed in a real-time neutron radiography system. The LIXI is coupled to a video camera and the real-time images can be observed in a TV monitor, and processed in a computer. In order to get the real-time system operational, the neutron radiography facility installed at the IEA-R1 m nuclear research reactor of the IPEN-CNEN/S P has been optimized. The most important improvements were the neutron/gamma ratio, the effective energy of the neutron beam, decrease of the scattered radiation at the irradiation position, and the additional shielding of the video camera. Several one-frame as well as computer processed images are presented. The overall Modulation Transfer Function for the real-time system was obtained from the resolution parameter p = 0:44 +- 0:04 mm; the system sensitivity, evaluated for a Perspex step wedge, was determined and the average value is 0:70 +- 0:09 mm. (author)

2003-06-01

228

Proteins of the kidney microvillar membrane  

International Nuclear Information System (INIS)

Two methods were used to label pig kidney microvillar membrane proteins from the luminal and cytoplasmic surfaces of closed membrane vesicles. The first method was lactoperoxidase-catalysed radioiodination. Lactoperoxidase and glucose oxidase were positioned inside or outside the vesicles, iodination being initiated by adding glucose and "1"2"5I. After electrophoresis of the proteins, asymmetric labelling patterns on radioautographs were observed. However the major disadvantage of this method was the high degree of intramembrane labelling of the fatty acid chains of membrane lipids. The second method overcame this disadvantage. A new hydophilic photoreagent, 3,5-di("1"2"5I)iodo-4-azidobenzenesulphonate, was transported by a Na"+-dependent system into microvillar vesicles, thus permitting labelling from either side of the membrane when the vesicles were photolysed. The activity of several microvillar peptidases survived the labelling reaction and they could be ...

229

Micro-strip metal foil detectors for the beam profile monitoring  

Energy Technology Data Exchange (ETDEWEB)

The Micro-strip Metal Foil Detectors (MMFD) designed and used for the Beam Profile Monitoring (BPM) are discussed. The results obtained for the MMFDs produced by different technologies are presented. The MMFD deposited onto the 20 {mu}m thick Si-wafer has been used for the BPM of the 32 MeV alpha-particle beam at the MPIfK (Heidelberg) Tandem generator. Another MMFD with totally removed Si-wafer at the working area has been applied for the on-line X-ray BPM at the HASYLAB (DESY). One may conclude that the developed technology of the micro-strip metal detector manufacturing allows to provide non-destructive measurement of X-ray intensity distribution over area of up to 50 mm{sup 2} with an accuracy of 10-20 {mu}m with a possibility of its improvement by a factor 5. A sub-micron position resolution is expected by applying electron lithography for the strip pattern production.

2005-07-01

230

Integral Field Unit Observations of NGC 4302: Kinematics of the Diffuse Ionized Gas Halo  

CERN Document Server

We present moderate resolution spectroscopy of extraplanar diffuse ionized gas (EDIG) emission in the edge-on spiral galaxy NGC 4302. The spectra were obtained with the SparsePak integral field unit (IFU) at the WIYN Observatory. The spectra are used to construct position-velocity (PV) diagrams at several ranges of heights above the midplane. Azimuthal velocities are directly extracted from the PV diagrams using the envelope tracing method, and indicate an extremely steep dropoff in rotational velocity with increasing height, with magnitude ~30 km/s/kpc. We find evidence for a radial variation in the velocity gradient on the receding side. We have also performed artificial observations of galaxy models in an attempt to match the PV diagrams. The results of a statistical analysis also favor a gradient of ~30 km/s/kpc. We compare these results with an entirely ballistic model of disk-halo flow, and find a strong dichotomy between the observed ...

2007-01-01

231

Anode Front-End Electronics for the Cathode Strip Chambers of the CMS Endcap Muon Detector  

CERN Document Server

The front-end electronics system for the anode signals of the CMS Endcap Muon cathode strip chambers has about 183000 channels. The purposes of the anode front-end electronics are to acquire precise muon timing information for bunch crossing number identification at the Level-1 muon trigger system and to provide a coarse radial position of the muon track. Each anode channel consists of an input protection network, amplifier, shaper, constant-fraction discriminator, and a programmable delay. The essential parts of the electronics include a 16-channel amplifier-shaper-discriminator ASIC CMP16 and a 16-channel ASIC D16G providing programmable time delay. The ASIC CMP16 was optimized for the large cathode chamber size (up to 3 x 2.5 m2) and for the large input capacitance (up to 200 pf). The ASIC combines low power consumption (30 mW/channel) with good time resolution (2 - 3 ns). The del ay ASIC D16G makes possible the alignment of signals with an ...

2005-01-01

232

Aluminum siting in mordenite and dealumination mechanism  

Science.gov (United States)

The dealumination of mordenite by acidification (HCl, HNO/sub 3/) and by SiCl/sub 4/ and steaming treatments is followed by high-resolution magic-angle-spinning solid-state /sup 29/Si and /sup 27/Al NMR spectroscopy. The combined use of these techniques leads to the determination of the silicon-aluminum ordering. It is demonstrated that aluminum atoms preferentially occupy tetrahedral positions in the four-membered rings of the mordenite structure. In addition, a mechanism of dealumination can be inferred, consisting in removing the aluminum atoms two by two from the four-membered rings. It is also possible to compute the number of SiOH groups left in the unit cell after the progressive removal of aluminum atoms: four groups per extracted Al atom are generated in the beginning of dealumination and this number gradually decreases to two, suggesting that a structural reorganization must necessarily occur for substantial dealumination. These ...

1986-10-09

233

Hilar cholangiocarcinoma: MR correlation with surgical and histological findings  

International Nuclear Information System (INIS)

Aim: To evaluate magnetic resonance cholangiography (MRC) with high-resolution dynamic gadolinium-enhanced magnetic resonance imaging (MRI) in determining the imaging features of hilar cholangiocarcinoma that relate to tumour extent and influence resectability. Materials and methods: Twenty-six patients that underwent resection were reviewed. Tumour location and extent, lobar atrophy, the degree of portal vein and hepatic artery involvement were recorded. The findings were correlated with surgical and histopathological findings. Results: Biliary assessment was concordant in 14 and discordant in eight of 14 stented and four of 12 non-stented patients. In 63/82 veins and 43/74 arteries results were fully concordant. The mean sensitivity, specificity, positive and negative predictive values (PPV, NPV) in predicting involvement of the main portal vein (MPV) at surgery were 83.3, 100, 100, and 92.5%; of the left main branch of the portal vein (LPV) ...

2010-10-01

234

GOCE, Satellite Gravimetry and Antarctic Mass Transports  

Science.gov (United States)

In 2009 the European Space Agency satellite mission GOCE (Gravity Field and Steady-State Ocean Circulation Explorer) was launched. Its objectives are the precise and detailed determination of the Earth's gravity field and geoid. Its core instrument, a three axis gravitational gradiometer, measures the gravity gradient components V xx , V yy , V zz and V xz (second-order derivatives of the gravity potential V) with high precision and V xy , V yz with low precision, all in the instrument reference frame. The long wavelength gravity field is recovered from the orbit, measured by GPS (Global Positioning System). Characteristic elements of the mission are precise star tracking, a Sun-synchronous and very low (260 km) orbit, angular control by magnetic torquing and an extremely stiff and thermally stable instrument environment. GOCE is complementary to GRACE (Gravity Recovery and Climate Experiment), another satellite gravity mission, launched in 2002. While ...

2011-03-01

235

Report of the Geostatistical Analysis of High Resolution ...  

Science.gov (United States)

... The variogram analysis of the high resolution imagery has shown that although more spatial scales have been identified than from the SPOT image ...

1998-05-01

236

Evaluation of left ventricular volumes in patients with congenital heart disease and abnormal left ventricular geometry. Comparison of MRI and transthoraic 3-dimensional echocardiography; Vergleich der transthorakalen 3D-Echokardiographie mit der MRT zur Bestimmung linksventrikulaerer Volumina bei Patienten mit pathologischer Ventrikelgeometrie aufgrund angeborener Herzfehler  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To assess the new method of 3-dimensional echocardiography in comparison to the 'gold standard' MRI as to its ability to calculate left ventricular volumes in patients with congenital heart disease. Materials and methods: Eighteen patients between the ages of 3.9 to 37.3 years (mean: 12.8{+-}9.7) with a geometrically abnormal left ventricle were examined using a 1.5 T scanner with a fast gradient-echo sequence (TR=14 ms, TE=2.6-2.9 ms, FOV=300-400 mm, flip angle=20 , matrix=128:256, slice thickness=5 mm, retrospective gating) in multislice-multiphase technique. Transthoracic 3D-echocardiography was performed with a 3.5 MHz transducer and a Tomtec {sup trademark} (Munich, Germany) system for 3D reconstruction. Results: Volume calculation was possible in all patients with 3D-echocardiography, but the muscle mass calculation only ...

2003-07-01

237

SUBMILLIMETER ARRAY OBSERVATIONS TOWARD THE MASSIVE STAR-FORMING CORE MM1 OF W75N  

International Nuclear Information System (INIS)

The massive star-forming core MM1 of W75N was observed using the Submillimeter Array with #approx#1'' and 2'' spatial resolutions at 217 and 347 GHz, respectively. From the 217 GHz continuum we found that the MM1 core consists of two sources, separated by about 1'': MM1a (#approx#0.6 M_s_u_n) and MM1b (#approx#1.4 M_s_u_n), located near the radio continuum sources VLA 2/VLA 3 and VLA 1, respectively. Within MM1b, two gas clumps were found to be expanding away from VLA 1 at about #+-#3 km s"-"1, as a result of the most recent star formation activity in the region. Observed molecular lines show emission peaks at two positions, MM1a and MM1b: sulfur-bearing species have emission peaks toward MM1a, but methanol and saturated species at MM1b. We identified high-temperature (#approx#200 K) gas toward MM1a and the hot core in MM1b. This segregation may result from the evolution of the massive star-forming core. In the very early phase of star ...

2010-11-10

238

Focused ion beam lithography for rapid prototyping of metallic films  

International Nuclear Information System (INIS)

We present FIB-lithography methods for rapid and cost-effective prototyping of metal structures covering the deep-submicron- to the millimeter-range in a single lithography cycle. Focused ion beam (FIB) systems are widely used in semiconductor industry and research facilities for both analytical testing and prototyping. A typical application is to apply electrical contact to micron-sized sensors/particles by FIB induced metal deposition. However, as for E-beam lithography, patterning times for large area bonding pads are unacceptably long, resulting in cost-intensive prototyping. In this work, we optimized FIB lithography processing for negative and positive imaging mode to form metallic structures for large-areas down do the sub-100 nm range. For negative lithography features are defined by implanting Ga"+-ions into a commercial photo resist, without affecting the underlying structures by impinging ions. The structures are highly suitable for following lift-off ...

2010-03-21

239

NORTH HILL CREEK 3-D SEISMIC EXPLORATION PROJECT  

Energy Technology Data Exchange (ETDEWEB)

Wind River Resources Corporation (WRRC) received a DOE grant in support of its proposal to acquire, process and interpret fifteen square miles of high-quality 3-D seismic data on non-allotted trust lands of the Uintah and Ouray (Ute) Indian Reservation, northeastern Utah, in 2000. Subsequent to receiving notice that its proposal would be funded, WRRC was able to add ten square miles of adjacent state and federal mineral acreage underlying tribal surface lands by arrangement with the operator of the Flat Rock Field. The twenty-five square mile 3-D seismic survey was conducted during the fall of 2000. The data were processed through the winter of 2000-2001, and initial interpretation took place during the spring of 2001. The initial interpretation identified multiple attractive drilling prospects, two of which were staked and permitted during the summer of 2001. The two initial wells were drilled in ...

2004-05-06

246

Valence electronic structure of Ti, Cr, Fe and Co in some alloys from K{beta}-to-K{alpha} X-ray intensity ratio studies  

Energy Technology Data Exchange (ETDEWEB)

K{beta}-to-K{alpha} X-ray intensity ratios of Ti, Cr, Fe and Co in pure metals and in Cr{sub 0.26}Fe{sub 0.74}, Cr{sub 0.80}Co{sub 0.20} and Ti{sub 0.80}Cr{sub 0.20} alloys have been measured following excitation by 59.54 keV {gamma}-rays from a 7400 MBq (200 mCi) {sup 241}Am point-source. The valence electronic structure of Ti, Cr, Fe and Co in the samples have been evaluated by the comparison of the measured K{beta}-to-K{alpha} intensity ratios with the results of multiconfiguration Dirac-Fock calculations performed for various electronic configurations of these metals. The 3d-electron populations obtained for pure metallic Ti, Cr, Fe and Co agree well with the results of band structure calculations of Papaconstantopoulos (Handbook of band structure of elemental solids, Plenum Press, New York, 1986). Our analysis indicates significant increase of 3d-electron population of Ti, Cr and Fe in the alloys ...

2002-10-01

247

Valence electronic structure of Ti, Cr, Fe and Co in some alloys from K#beta#-to-K#alpha# X-ray intensity ratio studies  

International Nuclear Information System (INIS)

K#beta#-to-K#alpha# X-ray intensity ratios of Ti, Cr, Fe and Co in pure metals and in Cr_0_._2_6Fe_0_._7_4, Cr_0_._8_0Co_0_._2_0 and Ti_0_._8_0Cr_0_._2_0 alloys have been measured following excitation by 59.54 keV #gamma#-rays from a 7400 MBq (200 mCi) "2"4"1Am point-source. The valence electronic structure of Ti, Cr, Fe and Co in the samples have been evaluated by the comparison of the measured K#beta#-to-K#alpha# intensity ratios with the results of multiconfiguration Dirac-Fock calculations performed for various electronic configurations of these metals. The 3d-electron populations obtained for pure metallic Ti, Cr, Fe and Co agree well with the results of band structure calculations of Papaconstantopoulos (Handbook of band structure of elemental solids, Plenum Press, New York, 1986). Our analysis indicates significant increase of 3d-electron population of Ti, Cr and Fe in the alloys with respect to ...

2002-10-01

248

Electron-ion recombination of neutral iron  

Energy Technology Data Exchange (ETDEWEB)

The total and state-specific electron-ion recombination rate coefficients are obtained for FeI. The calculations are carried out using a new ab initio method that incorporates both the radiative and the dielectronic recombination processes in an unified and self-consistent manner. The computations employ the close coupling approximation and the R-matrix method from atomic collision theory. A 52 state close coupling eigenfunction expansion dominated by the states of the ground 3d{sup 6}4s and excited 3d{sup 7}, 3d{sup 6}4p, 3d{sup 5}4s{sup 2}, and 3d{sup 5}4s4p configurations of FeII are used in the present calculations. The important electron correlation and radiation damping effects are included via explicit coupling of autoionization and radiative channels. This is the first ...

1997-04-01

249

Decay of "1"7"7T_a composite nucleus. Comparison of excitation functions for the reaction residues occurring in "1"2C + "1"6"5H_0 and "1"4N + "1"6"3D_y reactions  

International Nuclear Information System (INIS)

The experimental has been performed with a view to studying complete and incomplete fusion in "1"4N + "1"6"3D_y system below 7 MeV/nucleon. The excitation functions for several reactions have been measured using the activation technique and compared with the theoretical predictions based on statistical models. The codes ALICE-91 and CASCADE used earlier for the analysis of excitation functions in case of "1"2C + "1"6"5H_0 system have been used here also with the same set of input parameters. It has been observed that the theoretical calculations do not match with the experimental excitation functions well but the overall shape of the excitation function is reproduced satisfactorily. The composite nucleus ("1"7"7T_a) formed in this ("1"4N + "1"6"3D_y) case is the same as the one formed in "1"2C + "1"6"5H_0 system studied earlier. Measured excitation functions for the same decay channels in the two cases ...

2002-10-01

250

3D Atlas vertical plate oil transmission line field calculations. Final report  

Energy Technology Data Exchange (ETDEWEB)

Because of questions regarding current density and inductance estimates of the Atlas oil transmission line in the region where the vertical plates connect to the disk line, calculations using the 3D FE program Flux3d were initiated. Flux3d inductance values are nearly that estimated by D. Scudder. Calculations for three base designs of E. Ballard and D. Pierce were completed where several variations for each base design were used to determine the important parameters affecting inductance and to check inductance consistency. Flux3d showed for the first base design a very high current density of 36MA/m at the connection between the vertical and horizontal ground plates resulting in a magnetic pressure of 120 kpsi. The second base design modified this connection to reduce the current density to 20MA/m and 36 kpsi and for ...

1997-09-18

251

3-D depth migration: various methods and how they perform on real data  

Energy Technology Data Exchange (ETDEWEB)

3-D depth migration is one of the most active areas of research and development and it has been approached from different angles. An accurate algorithm which works in the space-frequency domain was introduced by Blacquiere et al. (1989). Unfortunately, it is computationally very expensive and not suitable for solving real-life 3-D migration problems. This led to the development of an alternative scheme (hale, 1990) which sacrifices some accuracy but is much more efficient. It is commonly referred to as the Hale-McClellan method. An alternative procedure known as reverse-time migration works in the space-time domain. It is based on the full wave equation and yields by far the most accurate results, but it requires extremely large computer resources. However, a series of new developments (Mufti et al, 1996) have made this algorithm a very practical tool even for migrating large exploration-scale ...

1997-07-01

252

Scale-dependent errors in the estimation of land-cover proportions. Implications for global land-cover datasets  

Energy Technology Data Exchange (ETDEWEB)

Aggregation of fine-resolution land-cover maps to coarser scales indicates that estimates of the proportions of land-cover types vary as a function of spatial resolution. The magnitude of these proportional errors in a forested area in northern California increase significantly as resolution exceeds a 90-m threshold. These errors could pose difficulties for the use of land-cover products generated from coarse-resolution sensors such as the NOAA-AVHRR and the MODIS sensor planned for the EOS program. The magnitude of the errors appears to be a function of the spatial resolution of the map, the original size of the land-cover classes, and the spatial patterns of the classes.

1994-05-01

253

Valence-electron configuration of Ti and Ni in TixNi1-x alloys from Kbeta-to-Kalpha X-ray intensity ratio studies.  

Science.gov (United States)

Kbeta-to-Kalpha X-ray intensity ratios of Ti and Ni have been measured in pure metals and in alloys of Ti(x)Ni(1-x) (x=0.7, 0.6, 0.5, 0.4 and 0.3) following excitation by 22.69 keV X-rays from a 10 mCi (109)Cd radioactive point source. The valence-electron configurations of these metals were determined by corporation of measured Kbeta-to-Kalpha X-ray intensity ratios with the results of multiconfiguration Dirac-Fock calculation for various valence-electron configurations. Valence-electron configurations of 3d-transition metals in alloys indicate significant differences with respect to the pure metals. Our analysis indicates that these differences arise from delocalization and/or charge transfer phenomena in alloys. Namely, the observed change of the valence-electron configurations of metals in alloys can be explained with the transfer of 3d electrons from one element to the other element and/or the ...

2010-01-28

254

Valence-electron configuration of Ti and Ni in TixNi1-x alloys from K?-to-K? X-ray intensity ratio studies  

International Nuclear Information System (INIS)

K?-to-K? X-ray intensity ratios of Ti and Ni have been measured in pure metals and in alloys of TixNi1-x (x=0.7, 0.6, 0.5, 0.4 and 0.3) following excitation by 22.69 keV X-rays from a 10 mCi 109Cd radioactive point source. The valence-electron configurations of these metals were determined by corporation of measured K?-to-K? X-ray intensity ratios with the results of multiconfiguration Dirac-Fock calculation for various valence-electron configurations. Valence-electron configurations of 3d-transition metals in alloys indicate significant differences with respect to the pure metals. Our analysis indicates that these differences arise from delocalization and/or charge transfer phenomena in alloys. Namely, the observed change of the valence-electron configurations of metals in alloys can be explained with the transfer of 3d electrons from one element to the other element and/or the rearrangement of ...

2010-06-01

255

Three-dimensional power system stabilizer  

Energy Technology Data Exchange (ETDEWEB)

Power system stabilizers (PSSs) are used to enhance damping of power system oscillations through excitation control of synchronous generator. The objective of the PSS is to generate a stabilizing signal, which produces a damping torque component on the generator shaft. Conventional PSSs are designed with the phase compensation technique in the frequency domain and include the lead-lag blocks whose parameters are determined according to a linearized power system model. The performance of conventional PSSs (CPSSs) depends upon the generator operating point and the system parameters, but a reasonable level of robustness can be achieved depending on the tuning method. This paper presents a new three-dimensional PSS (3D PSS), which uses rotor speed deviation, rotor acceleration and load angle deviation as input signals. The 3D PSS attempts to return the generator to the state-space origin, based on the ...

2010-07-15

256

Three-dimensional mise-a-la-masse modeling using horizontal well; Suihei kosei wo mochiita ryuden den`iho no sanjigen modeling  

Energy Technology Data Exchange (ETDEWEB)

The 3-D model program was developed to apply a mise-a-la-masse method to linear current sources with optional shapes. Mise-a-la-masse method is a bipolar mapping survey method using current sources installed in wells, and recently has been widely used for direct exploration of geothermal reservoirs. This method is also used for monitoring underground fluid as electrode arrangement of fluid flow tomography for surveying underground fluid (geothermal fluid, underground water, petroleum). In the geothermal reservoir exploration, the casing pipes of wells are used as linear current sources, and measured data are processed as those based on vertical current source. In the largely inclined well, the inclination of current sources should be considered. The 3-D modeling program was developed by difference calculus using the theoretical potential equation and apparent resistivity based on linear current sources ...

1996-10-01

257

Synthetic aperture radar image of agricultural fields with surface drainage network: simulation and spatial information retreival  

Science.gov (United States)

We develop a 3-D model to simulate the synthetic aperture radar (SAR) image formation process of an undulated vegetation canopy such as corn grown in fields with large periodic drainage reliefs. We explain how the simulated SAR image of undulated vegetation medium is obtained by the convolution of a 2-D slice of the 3-D simulated SAR system point spread function [(PSF), emulating the SAR beam modeled by a cosine modulated Gaussian], with the 2-D projection of the observed undulated vegetation canopy (modeled with scatterers randomly distributed in 3-D undulated space) followed by the extraction of each look envelope, the summation of looks, and sampling in azimuthal and range directions. Our model is useful to study the parameters involved in the formation and the analysis of SAR images of undulated vegetation medium. Validation of simulations made with actual ...

2001-10-01

258

Prediction of parallel NIKE3D performance on the KSR1 system  

Energy Technology Data Exchange (ETDEWEB)

Finite element method is one of the bases for numerical solutions to engineering problems. Complex engineering problems using finite element analysis typically imply excessively large computational time. Parallel supercomputers have the potential for significantly increasing calculation speeds in order to meet these computational requirements. This paper predicts parallel NIKE3D performance on the Kendall Square Research (KSR1) system. The first part of the prediction is based on the implementation of parallel Cholesky (U{sup T}DU) matrix decomposition algorithm through actual computations on the KSRI multiprocessor system, with 64 processors, at Oak Ridge National Laboratory. The other predictions are based on actual computations for parallel element matrix generation, parallel global stiffness matrix assembly, and parallel forward/backward substitution on the BBN TC2000 multiprocessor system at Lawrence Livermore National Laboratory. The ...

1995-05-01

259

Polymorphism in HTR3D shows different risks for acute chemotherapy-induced vomiting after anthracycline chemotherapy  

British Library Electronic Table of Contents (United Kingdom)

Aims: Serotonin (5-hydroxytryptamine 3; 5-HT3) receptors are involved in chemotherapy-induced nausea and vomiting (CINV), and 5-HT3 antagonists are part of the `gold standard' antiemetic treatment during chemotherapy. We investigated the correlation of common variants in 5-HT3 receptor subunit genes with the occurrence of CINV. Materials & methods: A total of 110 previously characterized chemotherapy-naive women with primary breast cancer treated with anthracycline-containing chemotherapy served as a study group for mutational analysis by direct sequencing. Eight common SNPs in the 5-HT3 receptor genes, HTR3A, HTR3B, HTR3D and HTR3E, were selected for association analysis. Results: A nonsynonymous variant in HTR3D, p.G36A (rs6443930), was found to be over-represented in nonresponders, assu...

2010-01-01

260

Core reactor calculation using the adaptive remeshing with a current error estimator  

International Nuclear Information System (INIS)

With the objective to improve the reactor physics calculation on a 2D and 3D nuclear reactor via the Diffusion Equation, an adaptive automatic finite element remeshing method, based on the elementary area (2D) or volume (3D) constraints, has been developed. The adaptive remeshing technique, guided by a posteriori error estimator, makes use of two external mesh generator programs: Triangle and TetGen. The use of these free external finite element mesh generators and an adaptive remeshing technique based on the current field continuity show that they are powerful tools to improve the neutron flux distribution calculation and by consequence the power solution of the reactor core even though they have a minor influence on the critical coefficient of the calculated reactor core examples. Two numerical examples are presented: the 2D IAEA reactor core numerical benchmark and the ...

261

CFD analysis on the flow distribution of steam generator of SMART-P  

Energy Technology Data Exchange (ETDEWEB)

The Computational Fluid Dynamics(CFD) study was conducted to assess the new design concept introduced to solve the issues on the flow deviation between SG cassettes and the supporting structure design of the flow distributing plate subjected to the flow induced vibration. Flow field from MCP to the bottom of SG was modeled for 2-dimensional(2D) CFD analysis and then sensitivity analysis on major design parameters was conducted using commercial CFD code, Fluent. The cases for detailed 3D analysis were selected based on the result of 2D analysis and the detailed 3-dimensional(3D) analysis was conducted for these selected cases using Fluent code. Flow field was modeled by RNG model and wall function, 2nd upwind scheme, porous model, structured or hybrid grid. The analysis result shows that the maximum deviation of flow distribution between SG cassettes was reduced upto about 0.1% and the pressure loss from ...

2003-12-01

262

Accuracy of FEM 3-D modeling in the electromagnetic methods; Denjiho ni okeru FEM 3 jigen modeling no seido  

Energy Technology Data Exchange (ETDEWEB)

Analytical methods considering 3-D resistivity distribution, in particular, finite element method (FEM) were studied to improve the reliability of electromagnetic exploration. Integral equation, difference calculus, FEM and hybrid method are generally used as computational 3-D modeling method. FEM is widely used in various fields because FEM can easily handle complicated shapes and boundaries. However, in electromagnetic method, the assumption of continuous electric field is pointed out as important problem. The normal (orthogonal) component of current density should be continuous at the boundary between media with different conductivities, while this means that the normal component of electric field is discontinuous. In FEM, this means that current channeling is not properly considered, resulting in poor accuracy. Unless this problem is solved, FEM modeling is not practical. As one of the solutions, it ...

1996-10-01

263

A technique for the fast calculation of three-dimensional photon dose distributions using the superposition model  

International Nuclear Information System (INIS)

Techniques for reducing computation time in 3D photon dose calculations are addressed with specific emphasis given to the convolution/superposition approach. A single polyenergetic superposition model calculating absorbed dose per incident photon fluence (Gy cm"2) was developed in terms of TERMA and a total energy deposition kernel (a total point spread function). A novel approach was devised for reducing calculation time. The method, named the CF method, was based on the use of a conventional, fast model (here a modified power-law method was used) for the generation of 3D dose distributions on a fine dose matrix. Superposition calculations were carried out on a coarse matrix and calculation speed was increased simply by reducing the number of calculations. A set of correction factors was derived on the coarse grid from the ratio of the dose values from superposition to those from the conventional ...

1997-08-01

265

Further development of the unified multiscale Eulerian model for a broad range of spatial and temporal scales within the new National Environmental Modeling System  

Science.gov (United States)

A unified Nonhydrostatic Multiscale Model on the Arakawa B grid (NMMB) designed for a broad range of spatial and temporal scales has been under development within the Earth System Modeling Framework (ESMF) at the National Centers for Environmental Prediction (NCEP) as a part of the new National Environmental Modeling System (NEMS). The model follows the general modeling philosophy of the NCEP's WRF NMM grid-point regional dynamical core. The model uses the regular latitude-longitude grid for the global domain, and a rotated latitude-longitude grid in regional applications. The nonhydrostatic component of the model dynamics is introduced through an add-on module that can be turned on or off depending on resolution. The "isotropic" quadratic conservative finite-volume horizontal differencing employed in the model conserves a variety of basic and derived dynamical and quadratic quantities and preserves some important properties of differential operators. Among these, ...

2009-04-01

266

Time-dependent 3-D dterministic transport on parallel architectures using Dantsys/MPI  

Energy Technology Data Exchange (ETDEWEB)

In addition to the ability to solve the static transport equation, we have also incorporated time dependence into our parallel 3-D S{sub {ital N}} code DANTSYS/MPI. Using a semi-implicit scheme, DANTSYS/MPI is capable of performing time-dependent calculations for both fissioning and pure source driven problems. We have applied this to various types of problems such as nuclear well logging and prompt fission experiments. This paper describes the form of the time- dependent equations implemented, their solution strategies in DANTSYS/MPI including iteration acceleration, and the strategies used for time-step control. Results are presented for a model nuclear well logging calculation.

1996-12-31

267

The CDF intermediate silicon layers detector  

Energy Technology Data Exchange (ETDEWEB)

The intermediate silicon layers detector (ISL) was proposed as a part of the upgraded CDF detector at the RUN-II of the Tevatron mean value of pp collider at Fermilab, scheduled to start in year 2000. The ISL is a large-radius (20-30 cm) silicon tracker with a total active area of about 3.5 m. Located in the region between the silicon vertex detector and the central outer tracker, the ISL will allow tracking in the forward region and significantly improve it in the central area. Together with the SVX II the ISL forms a standalone, 3D silicon tracker. The challenge is to build a low-cost device which provides precise 3 D tracking in a approximately equal to 2 m long area with a minimal amount of material for the supporting structure. The conceptual design and the status of the project are reviewed.

1999-11-01

268

Resonant neutralization of He ions into excited states at Cu(110) and Ni(110) surfaces  

Energy Technology Data Exchange (ETDEWEB)

He ions incident at grazing angles on Cu(110) and Ni(110) surfaces are neutralised into triplet and singlet states, of which the 3p, 3d and 4d upper states are accessible to optical spectroscopy. In the energy range from 500 eV to 15 keV no significant energy dependence of the relative intensities of singlet and triplet lines was observed for scattering on Cu(110). The intensities from Ni(110) are higher and the singlet to triplet intensity ratio of the 3d to 2p transition is about 6% smaller than that from Cu(110). The results can be explained well by assuming resonant charge capture into excited He and intermediate formation of negative He/sup -/ states.

1984-03-01

269

Resonant neutralization of He ions into excited states at Cu(110) and Ni(110) surfaces  

International Nuclear Information System (INIS)

He ions incident at grazing angles on Cu(110) and Ni(110) surfaces are neutralised into triplet and singlet states, of which the 3p, 3d and 4d upper states are accessible to optical spectroscopy. In the energy range from 500 eV to 15 keV no significant energy dependence of the relative intensities of singlet and triplet lines was observed for scattering on Cu(110). The intensities from Ni(110) are higher and the singlet to triplet intensity ratio of the 3d to 2p transition is about 6% smaller than that from Cu(110). The results can be explained well by assuming resonant charge capture into excited He and intermediate formation of negative He"- states. (orig.).

1983-07-01

270

Recent progress in energy-filtered high energy X-ray photoemission electron microscopy using a Wien filter type energy analyzer  

International Nuclear Information System (INIS)

Energy-filtered X-ray photoemission electron microscopy (EXPEEM) is a microscopy technique which has the potential to provide surface chemical mapping during surface chemical processes on the nanometer scale. We studied the possibilities of EXPEEM using a Wien filter type energy analyzer in the high energy X-ray region above 1000 eV. We have successfully observed the EXPEEM images of Au islands on a Ta sheet using Au 3d_5_/_2 and Ta 3d_5_/_2 photoelectron peaks which were excited by 2380 eV X-rays emitted from an undulator (BL2A) at Photon Factory. Our recent efforts to improve the sensitivity of the Wien filter energy analyzer will also be discussed.

2004-10-15

271

On the anatomy of the adsorption heat versus loading as a function of temperature and adsorbate for a graphitic surface  

British Library Electronic Table of Contents (United Kingdom)

In this paper we review and classify the various patterns of isosteric heat versus loading for adsorption of gases on graphitised thermal carbon black at temperatures ranging from below the 3D triple point to temperatures above it, but less than the 3D critical point. We have identified the features of heat curve and highlighted the microscopic origin of these features. The patterns vary with temperature and with the relative strength of the fluid-fluid interaction and solid-fluid interaction. For simple adsorptives (by simple we meant there is no strong association between fluid particles), the heat curve is typified by fluid-fluid attraction and layering phenomena. For adsorptives showing strong association such as water, ammonia and methanol, the heat curve essentially begins below the ...

2008-01-01

272

Improved recovery demonstration for Williston Basin carbonates. Quarterly report, July 1 - September 30, 1996  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this project is to demonstrate targeted infill and extension drilling opportunities, better determinations of oil-in- place, methods for improved completion efficiency and the suitability of waterflooding in certain shallow-shelf carbonate reservoirs in the Williston Basin, Montana, North Dakota and South Dakota. Improved reservoir characterization utilizing 3-dimensional (3D) and multi-component seismic are being investigated for identification of structural and stratigraphic reservoir compartments. Field demonstrations are in progress to collect data for evaluation of horizontal completions in both the Red River and Ratcliffe. A vertical well in the Red River will test attribute analysis of 3D seismic data for prediction of porosity development. Additional seismic acquisitions and interpretation are in progress for both the Ratcliffe and Red River. A water-injectivity test in a new ...

1996-12-31

273

Effect of varying the vertical dimension of connectors of cantilever cross-arch fixed dental prostheses in patients with severely reduced osseous support: A three-dimensional finite element analysis  

British Library Electronic Table of Contents (United Kingdom)

Statement of problem Inadequate dimensioning of the connectors in a cantilever cross-arch fixed dental prosthesis (FDP) in perioprosthetic patients jeopardizes the prognosis of the restoration. Purpose The purpose of this study was to investigate the effect of increasing the vertical dimension (VD) on the maximum stress developed within the connectors during the static loading of a cross-arch FDP extended as a 1- and 2-unit cantilever. Material and methods Six digital models were developed, derived from a 3-dimensional (3-D) initial model. In the initial model, the teeth were prepared for metal ceramic restorations and splinted with a cross-arch FDP, extended as a 1- or 2-unit cantilever. The VDs of the connectors proximal to the retaining abutment were 3, 4, or 5 mm. A 3-D finite element ...

2010-01-01

274

Discretization of complex 3-D flow domains with adaptive hybrid grids  

Energy Technology Data Exchange (ETDEWEB)

There is an ever increasing demand to perform flow simulations that incorporate the complete details of geometry as well as sophisticated flow physics. This has led to the development of numerical algorithms that can simulate the actual flow phenomena with greater fidelity. However, the success of these algorithms hinges on the grid that models the geometry. Grid generation methods for 2-D models have long existed and the general lack of complexity of the simpler 2-D models has not quite challenged the efforts in this area. However, demands for generating better 3-D geometric models for flow simulations involving complex geometries have completely changed the perspective of grid generation strategies. As a consequence, grid generation efforts have earned equal significance as that of numerical solver efforts.

1996-12-31

275

Development of Computational Models for Pyrochemical Electrorefiners of Nuclear Waste Transmutation Systems  

International Nuclear Information System (INIS)

The objective of this project is to develop multi-dimensional computational models in order to improve the operation of uranium electrorefiners currently used in pyroprocessing technology. These 2-D (US) and 3-D (ROK) mathematical models are based on the fundamental physical and chemical properties of the electrorefiner processes. The validated models by compiled and evaluated experimental data could provide better information for developing advanced electrorefiners for uranium recovery. The research results in this period are as follows: - Successfully assessed a common computational platform for the modeling work and identify spatial characterization requirements. - Successfully developed a 3-D electro-fluid dynamic electrorefiner model. - Successfully validated and benchmarked the two multi-dimensional models with compiled experimental data sets

2008-08-01

276

Contribution to 3D-operational geodesy. Pt. 3  

Energy Technology Data Exchange (ETDEWEB)

Whereas in part 1 and 2 the detailed observation equations of terrestrial type for an integrated geodetic model are presented this paper will outline how the theory is transferred in an operational program. The main lines of functions of the FORTRAN IV program are discussed. Since the input specifications as well as the data requirements are described in detail and illustrated by example of input and output part 3 can serve as an user-guide for OPERA. OPERA is an acronym for operational adjustment. Besides the integrated determination of 3D-geocentric coordinates and the gravity disturbing potential the program can handle all cases of traditional geodesy (in total 13 variants of solution are provided) equivalent also with adjustments in ellipsoidal coordinates B, L or H, as well as constrained adjustments, pure prediction of the gravity disturbing field, etc.

1983-01-01

277

Constrained NBMPR analogue synthesis, pharmacophore mapping and 3D-QSAR modeling of equilibrative nucleoside transporter 1 (ENT1) inhibitory activity  

British Library Electronic Table of Contents (United Kingdom)

Conformationally constrained analogue synthesis was undertaken to aid in pharmacophore mapping and 3D-QSAR analysis of nitrobenzylmercaptopurine riboside (NBMPR) congeners as equilibriative nucleoside transporter 1 (ENT1) inhibitors. In our previous study [J. Med. Chem. 2003, 46, 831-837], novel regioisomeric nitro-1,2,3,4-tetrahydroisoquinoline conformationally constrained analogues of NBMPR were synthesized and evaluated as ENT1 ligands. 7-NO2-1,2,3,4-Tetrahydroisoquino-2-yl purine riboside was identified as the analogue with the nitro group in the best orientation at the NBMPR binding site of ENT1. In the present study, further conformational constraining was introduced by synthesizing 5prime-O,8-cyclo derivatives. The flow cytometrically determined binding affinities indicated that the...

2008-01-01

278

Automated three-dimensional X-ray analysis using a dual-beam FIB  

International Nuclear Information System (INIS)

We present a fully automated method for three-dimensional (3D) elemental analysis demonstrated using a ceramic sample of chemistry (Ca)MgTiO_x. The specimen is serially sectioned by a focused ion beam (FIB) microscope, and energy-dispersive X-ray spectrometry (EDXS) is used for elemental analysis of each cross-section created. A 3D elemental model is reconstructed from the stack of two-dimensional (2D) data. This work concentrates on issues arising from process automation, the large sample volume of approximately 17x17x10 #mu#m"3, and the insulating nature of the specimen. A new routine for post-acquisition data correction of different drift effects is demonstrated. Furthermore, it is shown that EDXS data may be erroneous for specimens containing voids, and that back-scattered electron images have to be used to correct for these errors.

2007-08-01

279

Applicator reconstruction and applicator shifts in 3D MR-based PDR brachytherapy of cervical cancer  

British Library Electronic Table of Contents (United Kingdom)

Purpose To evaluate the methods of applicator reconstruction in 3D MR-based planning for brachytherapy of cervical cancer, and to investigate applicator shifts and changes in DVH parameters during PDR treatment. Methods For each application MR scans with applicator in situ were made: three T2-weighted (4.5mm slices) Turbo Spin Echo (TSE) scans and a balanced Steady State Free Precession scan (1.5mm). Three observers tested two applicator reconstruction methods: (A) directly on the bSSFP scan and (B) on a resampled combination of the three T2-weighted scans. For 10 patients MR imaging was repeated on the second day of each PDR fraction to determine applicator shifts and changes in DVH parameters. Results For both applicator reconstruction methods the interobserver variation for the DVH para...

2009-01-01

280

Application of Vertically Integrated Electronics to Intelligent Trackers  

CERN Document Server

At Super-LHC luminosity it is expected that the standard suite of L1 triggers for CMS will saturate. Information from the tracker will be needed to reduce trigger rates to satisfy the L1 bandwidth. Tracking trigger modules which correlate information from closely-spaced sensor layers to form an on-detector momentum filter are being developed by several groups. We report on a trigger module design which utilizes three dimensional IC technology to incorporate chips which are connected both to the top and bottom sensor, providing the ability to filter information locally. A demonstration chip, the VICTR, has been submitted to the Chartered/Tezzaron two-tier 3D run coordinated by Fermilab. We report on the 3D design concept, the status of the VICTR chip and associated sensor integration utilizing oxide bonding.

2010-01-01

281

Improvement of spatial resolution in the longitudinal direction for isotropic imaging in helical CT  

Energy Technology Data Exchange (ETDEWEB)

Experiments were conducted to confirm the isotropic spatial resolution of multislice CT with a 0.5 mm slice thickness. Isotropic spatial resolution means that the spatial resolution in the transaxial plane (X-Y plane) and that in the longitudinal direction (Z direction) are equivalent. To obtain point spread function (PSF) values in the X-Y-Z directions, three-dimensional voxel data were obtained by helical scanning of a bead phantom. The modulation transfer function (MTF) values were then obtained by three-dimensional Fourier transform of the PSF. Evaluation of the spatial resolution in the X-Y-Z directions by the MTF values showed that the spatial resolution in the Z direction does not depend on the reconstruction kernel used. It was also found that the spatial resolution in the Z direction, as compared with that in the X-Y plane, is superior with the standard ...

2007-02-07

282

Luminescence of Strontianite (SrCO{sub 3}) from Strontian (Scotland, UK)  

Energy Technology Data Exchange (ETDEWEB)

An historic Strontianite-type specimen from Strontian, Scotland, UK, was characterized to broaden our knowledge on luminescence properties of common carbonates. These fibrous aggregates are Strontianite (Sr{sub x}Ca{sub 1-x}CO{sub 3}) with circa 6% of CaO, interfacial water, hydrosilicate anions and substitutional divalent cations, e.g., Ca{sup 2+}, Mn{sup 2+}, Fe{sup 2+} in structural Sr{sup 2+} positions. The specimen was analyzed by X-ray Fluorescence Spectrometry (XRF), Environmental Scanning Electron Microscopy coupled with an Energy Dispersive X-ray Spectroscopy (ESEM-EDS) probe, Spatially-resolved Cathodoluminescence under the Scanning Electron Microscope (SEM-CL), Differential-Thermal Analyses (DTA), Thermogravimetry (TG), Thermoluminescence (TL), Radioluminescence (RL) and High Resolution Spectra Thermoluminescence (3DTL), to gain an overview of the spectral emissions, the defect linkages were modified by heating from room temperature ...

2009-04-15

283

m0905250.imq  

Science.gov (United States)

zb l:7R cq~` ;qqw scq- !;m#] QLBr90 NJThh 4vwCb :o5!3: $|1y .8Bj -A}8 -^uY .,4G WDl7 72qBD ;tDGCq MXgF 9[1"r3 :D)nJ+ &&orq l'j"c/ Lk^q 't|#b c3~5 :&c|$ ...

284

The chemistry of the p-block elements with thioether, selenoether and telluroether ligands.  

Science.gov (United States)

The synthesis and structures of acyclic and macrocyclic thio-, seleno- and telluro-ether complexes of the metallic and metalloid elements of Groups 13-16 reported since 2000 are described. The diverse structures range from discrete monomers through to infinite 1-, 2- or 3-D polymers. The coordination chemistry in this area is quite different to familiar d-block chemistry and the underlying factors are explored. PMID:21706103

2011-06-27

285

Steam generator PGV-1000 thermal-hydraulics  

International Nuclear Information System (INIS)

The main features are presented of a computer programme for 3-D thermohydraulic and thermodynamic analysis of the PGV-1000 horizontal steam generator used at the Temelin NPP. The programme provides analyses of primary side hydraulics, heat exchange behavior and the steam generator secondary side thermohydraulics and thermodynamics. Given are calculated data on the circulation flow rate, void fraction, heat transfer dynamics and the swelled level. (Z.S.) 9 figs.

1995-09-21

286

Magnetic and valence transitions in CePd_2_-_xMn_xSi_2:L_I_I_I edge study  

International Nuclear Information System (INIS)

We report on solid solution CePd_2_-_xMn_xSi_2 which shows an interesting transition of the Ce-ion from magnetism in a Kondo regime to an intermediate valence state coupled with a strongly magnetic 3d sublattice. ((orig.)).

287

Magnetic and valence transitions in CePd[sub 2-x]Mn[sub x]Si[sub 2]:L[sub III] edge study  

Energy Technology Data Exchange (ETDEWEB)

We report on solid solution CePd[sub 2-x]Mn[sub x]Si[sub 2] which shows an interesting transition of the Ce-ion from magnetism in a Kondo regime to an intermediate valence state coupled with a strongly magnetic 3d sublattice. ((orig.))

1994-04-01

288

Comparison of EH with SW-Xsub(alpha) calculations  

International Nuclear Information System (INIS)

The electronic structure of octahedral metal atom clusters Me_6 of 3d, 4d, and 5d transition metal atoms (V, Cr; Nb, Mo; Ta, W) has been calculated applying two different quantum-chemical approximation methods (Extended Hueckel (EH) method; SW-Xsub(alpha) method). Equilibrium structures, energy level schemes, Fermi energies and band widths as well as densities of states of clusters are discussed in detail.

1981-01-01

289

Calculation of 3-D electrical field distribution around technical devices in the vicinity of high voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

The influence that electromagnetic fields have on mechanical and electronic equipment was discussed. A three dimensional numerical simulation model of electric fields around high voltage power transmission lines was described. 4 refs., 1 tab., 5 figs.

1997-12-31

290

Calculation of 3-D electrical field distribution around technical devices in the vicinity of high voltage transmission lines  

International Nuclear Information System (INIS)

The influence that electromagnetic fields have on mechanical and electronic equipment was discussed. A three dimensional numerical simulation model of electric fields around high voltage power transmission lines was described. 4 refs., 1 tab., 5 figs.

1997-08-24

291

3D Time-Dependent Model Of The Dusty-Gas Atmosphere Of Comet 67P/Churyumov-Gerasimenko: Recent Improvements.  

Science.gov (United States)

Under support from the French Space Agency (CNES), a 3D+t dusty-gas model of Comet 67P/Churyumov-Gerasimenko is being developed, to compute, from the first 2014 Rosetta orbital data, the aerodynamic forces exerted on the Rosetta orbiter and on the descent lander. We report the recently developed dust dynamics part of the code. The multi-species (presently H2O and CO) gas code is optimized in terms of computational speed owing to the use of two complementary methods: (a) 3D+t Direct Simulation Monte Carlo (DSMC) runs in the non-equilibrium regions adjacent to the surface and very distant from it, and (b) solutions of the Navier-Stokes equations in-between. The model is used presently using Lamy et al. (Space Sci. Rev., 2007, 128, 23) coarse information on 67P nucleus shape and rotation, and a range of possible gas production rates Q for the early Rosetta observations at rh 3 AU (Q 1026 - 1027 s-1). In ...

2010-10-01

292

3-D numerical simulation of the transient electromagnetic pulse coupling to double cylinder object  

International Nuclear Information System (INIS)

In this paper, finite-difference time-domain method is used to research the transient electromagnetic pulse (EMP) coupling to the cylinder object which is shielded in another shielding cavity with a hole numerically. The different coupling effectiveness of three transient EMP is simulated. The distribution of the electric field in the shielding cavity and the current on the cavity are researched. The shielding effectiveness is evaluated. (authors)

2006-10-21

293

28: Calculation of 3D dose distribution for photons in inhomogeneous media  

International Nuclear Information System (INIS)

A method for calculation of absorbed dose distributions in three dimensions for 1-20 MeV photons is presented. The method uses convolution/superposition of photon fluence distributions with energy scattering kernels. Results for Co-60 and X-ray beams in homogeneous and inhomogeneous media are compared with measurements. Good agreement is found between calculations and measurements. 8 refs.; 3 figs.

294

Determination of cartilage thickness in the ankle joint. MRT (1,5 T) comparative anatomical study; Bestimmung der Knorpeldicke am oberen Sprunggelenk. Eine MRT(1,5 T)-anatomische Vergleichsstudie  

Energy Technology Data Exchange (ETDEWEB)

Purpose: The aim of this study was to evaluate the accuracy of MRI in the measurement of cartilage thickness of the ankle joint in comparison to pathologic and histologic specimens. Patients and methods: The ankle joints of four fresh cadaver feet were imaged on a 1.5 T MR-unit in the coronal plane. Standard T{sub 1}-weighted spin echo (SE) and a T{sub 1}-weighted 3D-GE (FLASH-3D) sequence with fat saturation were applied. Following MR imaging, the talus was explanted and cut parallel to the MR images for macroscopic evaluation and histologic specimens were prepared. MRI measurements of the cartilage thickness of the talus were carried out in two ways: Without and with consideration of a transition zone of intermediate signal intensity between hyperintense cartilage and hypointense cortical bone. The data were compared with the anatomic specimens as the gold standard expressing the difference as a ...

1997-04-01

295

The clinical significance of Fuji computed radiography on lateral chest radiogram  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to clarify the benefits of digital lateral chest radiogram. In the basic study, the modulation transfer factor (MTF) and the wiener spectra (WS) of conventional screen film (CSF) and Fuji computed radiography (FCR) were measured. The visibility of the simulated nodules on FCR using 3 human bodies was subjectively compared with that on CSF by 13 observers. In the clinical study, the visibility of the normal structures on FCR was subjectively compared with that on CSF using 50 lateral chest radiograms by 10 observers. The diagnostic performance to detect pulmonary nodules on FCR was also compared with that on CSF using each 30 positive and negative cases by 8 observers. In the basic study, the MTF of FCR was superior to that of CSF, and the WS of FCR displayed in half size was superior to that of CSF. In all exposure conditions, the visibility of the nodules on FCR in the pulmonary apex was inferior to that on CSF, while FCR was superior ...

1995-02-01

296

The clinical significance of Fuji computed radiography on lateral chest radiogram  

International Nuclear Information System (INIS)

The purpose of this study was to clarify the benefits of digital lateral chest radiogram. In the basic study, the modulation transfer factor (MTF) and the wiener spectra (WS) of conventional screen film (CSF) and Fuji computed radiography (FCR) were measured. The visibility of the simulated nodules on FCR using 3 human bodies was subjectively compared with that on CSF by 13 observers. In the clinical study, the visibility of the normal structures on FCR was subjectively compared with that on CSF using 50 lateral chest radiograms by 10 observers. The diagnostic performance to detect pulmonary nodules on FCR was also compared with that on CSF using each 30 positive and negative cases by 8 observers. In the basic study, the MTF of FCR was superior to that of CSF, and the WS of FCR displayed in half size was superior to that of CSF. In all exposure conditions, the visibility of the nodules on FCR in the pulmonary apex was inferior to that on CSF, while FCR was superior ...

1995-01-01

297

The Infrared Camera (IRC) for the ASTRO-F infrared astronomical satellite  

Science.gov (United States)

The Infrared Camera (IRC) is one of the scientific focal plane instruments on board the ASTRO-F infrared astronomical satellite. The IRC is designed for wide field imaging and slit-less spectroscopic observations at near- and mid-infrared wavelengths. The IRC consists of three channels; NIR, MIR-S and MIR-L, each of which covers wavelengths of 2-5, 5-12 and 12-26 micron, respectively. All channels adopt compact refractive optical designs. Large format array detectors (a InSb 512 x 412 array and two Si:As IBC 256 x 256 arrays) are employed. Each channel has 10 x 10 arcminutes wide FOV with diffraction-limited angular resolution of 70cm aperture of the liquid helium cooled telescope at wavelengths over 5 micron. A 6-position filter wheel is placed at the aperture stop in each channel, and has three band-pass filters, two grisms/prisms and a mask for dark current measurements. The 5 sigma sensitivity of one pointed observation is estimated to be ...

2004-01-01

298

Target area chamber system design for the National Ignition Facility  

International Nuclear Information System (INIS)

The National Ignition Facility (NIF) is a proposed Department of Energy facility which will contribute to the resolution of important Defense Program and inertial fusion energy issues for energy production in the future. The NIF will consist of a laser system with 192 independent beamlets transported to a target chamber. The target chamber is a multi-purpose structure that provides the interface between the target and the laser optics. The chamber must be capable of achieving moderate vacuum levels in reasonable times; it must remain dimensionally stable within micron tolerances, provide support for the optics, diagnostics, and target positioner; it must minimize the debris from the x-ray and laser light environments; and it must be capable of supporting external neutron shielding. The chamber must also be fabricated from a low neutron activation material. The fusion reaction in the target gives off neutrons, x-ray and gamma rays. The x-rays and gamma rays interact ...

1994-06-19

299

Studies on formation and structures of ultrafine Cu precipitates in Fe-Cu model alloys for reactor pressure vessel steels using positron quantum dot confinement in the precipitates by their positron affinity. JAERI's nuclear research promotion program, H11-034 (Contract research)  

Energy Technology Data Exchange (ETDEWEB)

Positron annihilation experiments on Fe-Cu model dilute alloys of nuclear reactor pressure vessel (RPV) steels have been performed after neutron irradiation in JMTR. Nanovoids whose inner surfaces were covered by Cu atoms were clearly observed. The nanovoids transformed to ultrafine Cu precipitates by dissociating their vacancies after annealing at around 400degC. The nanovoids and the ultrafine Cu precipitates are strongly suggested to be responsible for irradiation-induced embrittlement of RPV steels. Effects of Ni, Mn and P addition on the nanovoid and Cu precipitate formations were also studied. The nanovoid formation was enhanced by Ni and P, but suppressed by Mn. The Cu precipitates after annealing around 400degC were almost free from these doping elements and hence were pure Cu in the chemical composition. Furthermore the Fermi surface of the 'embedded' Cu precipitates with a body centered cubic crystal structure was obtained from two dimensional angular ...

2003-03-01

300

Structures of trihydroxynaphthalene reductase-fungicide complexes: implications for structure-based design and catalysis  

Energy Technology Data Exchange (ETDEWEB)

Trihydroxynaphthalene reductase catalyzes two intermediate steps in the fungal melanin biosynthetic pathway. The enzyme, a typical short-chain dehydrogenase, is the biochemical target of three commercial fungicides. The fungicides bind preferentially to the NADPH form of the enzyme. Three X-ray structures of the Magnaporthe grisea enzyme complexed with NADPH and two commercial and one experimental fungicide were determined at 1.7 {angstrom} (pyroquilon), 2.0 {angstrom} (2,3-dihydro-4-nitro-1H-inden-1-one, 1), and 2.1 {angstrom} (phthalide) resolutions. The chemically distinct inhibitors occupy similar space within the enzyme's active site. The three inhibitors share hydrogen bonds with the side chain hydroxyls of Ser-164 and Tyr-178 via a carbonyl oxygen (pyroquilon and 1) or via a carbonyl oxygen and a ring oxygen (phthalide). Active site residues occupy similar positions among the three structures. A buried water molecule that is ...

2010-03-08

301

Structural definition of the active site and catalytic mechanism of 3,4-dihydroxy-2-butanone 4-phosphate synthase  

Energy Technology Data Exchange (ETDEWEB)

X-ray crystal structures of L-3,4-dihydroxy-2-butanone-4-phosphate synthase from Magnaporthe grisea are reported for the E-SO{sub 4}{sup 2-}, E-{sub 4}{sup 2-}-Mg{sup 2+}, E-SO{sub 4}{sup 2-}-Mn{sup 2+}, E-SO{sub 4}{sup 2-}-Mn{sup 2+}-glycerol, and E-SO{sub 4}{sup 2-}-Zn{sup 2+} complexes with resolutions that extend to 1.55, 0.98, 1.60, 1.16, and 1.00 {angstrom}, respectively. Active-site residues of the homodimer are fully defined. The structures were used to model the substrate ribulose 5-phosphate in the active site with the phosphate group anchored at the sulfate site and the placement of the ribulose group guided by the glycerol site. The model includes two Mg{sup 2+} cations that bind to the oxygen substituents of the C2, C3, C4, and phosphate groups of the substrate, the side chains of Glu37 and His153, and water molecules. The position of the metal cofactors and the substrate's phosphate group are further stabilized by an ...

2010-03-08

302

Real-time neutron radiography; Radiografia com neutrons em tempo-real  

Energy Technology Data Exchange (ETDEWEB)

The main objective of the present thesis was develop and get operational a real-time neutron radiography system, at the IPEN-CNEN/SP. This system is installed inside the shielding of an old facility, designed in 1988, for film radiography, which is installed at the beam-hole 08 of the 5 MW, IEA-R1 Nuclear Research Reactor. The most important modifications at the such facility were the increase of the {gamma}-radiation filter thickness, increase of the inner area of the shielding, design of a neutron collimator and a light tight box. The main characteristics of the neutron beam at the irradiation position are: flux: 1 x 10{sup 6}n/cm{sup 2}s, collimation ratio 70, effective energy 7 meV, diameter 20 cm, neutron/{gamma} ratio {approx} 10{sup 6}n/cm{sup 2}mrem. The real-time images have been obtained by means of an imaging system that consists of a screen scintillator, a light intensifier, a video camera, a digitizing frame grabber and a computer. The device composed ...

2000-07-01

303

Real-time neutron radiography at Texas A and M University  

Energy Technology Data Exchange (ETDEWEB)

A real-time neutron radiography imaging system has been installed at the Texas A and M University Nuclear Science Center. The system employs a scintillating screen viewed by a low-light TV camera with a front surface mirror placed at 45deg to the neutron beam. The key components of the system are the neutron camera and the image capture and processing unit. The neutron camera uses an NE 426 scintillating screen (ZnS), front surface mirror, remote focus and zoom lens, intensified relay optics (IRO) and monochrome CCD television camera. The image capture and processing unit consists of an IBM PC AT-compatible computer, arithmetic frame grabber, frame processor and high-resolution color monitor. The neutron camera is similar to others using a silicon intensified target (SIT) television camera to provide a TV image of the low-level light from a NE 426 screen. The IRO and CCD camera are used in place of the SIT camera. The computer digitizes the TV image (512x512x8 bit) ...

1990-12-20

304

Real-time neutron radiography at Texas A and M University  

International Nuclear Information System (INIS)

A real-time neutron radiography imaging system has been installed at the Texas A and M University Nuclear Science Center. The system employs a scintillating screen viewed by a low-light TV camera with a front surface mirror placed at 45deg to the neutron beam. The key components of the system are the neutron camera and the image capture and processing unit. The neutron camera uses an NE 426 scintillating screen (ZnS), front surface mirror, remote focus and zoom lens, intensified relay optics (IRO) and monochrome CCD television camera. The image capture and processing unit consists of an IBM PC AT-compatible computer, arithmetic frame grabber, frame processor and high-resolution color monitor. The neutron camera is similar to others using a silicon intensified target (SIT) television camera to provide a TV image of the low-level light from a NE 426 screen. The IRO and CCD camera are used in place of the SIT camera. The computer digitizes the TV image (512x512x8 bit) ...

1990-12-01

305

Real-time neutron radiography  

International Nuclear Information System (INIS)

The main objective of the present thesis was develop and get operational a real-time neutron radiography system, at the IPEN-CNEN/SP. This system is installed inside the shielding of an old facility, designed in 1988, for film radiography, which is installed at the beam-hole 08 of the 5 MW, IEA-R1 Nuclear Research Reactor. The most important modifications at the such facility were the increase of the #gamma#-radiation filter thickness, increase of the inner area of the shielding, design of a neutron collimator and a light tight box. The main characteristics of the neutron beam at the irradiation position are: flux: 1 x 10"6n/cm"2s, collimation ratio 70, effective energy 7 meV, diameter 20 cm, neutron/#gamma# ratio #approx# 10"6n/cm"2mrem. The real-time images have been obtained by means of an imaging system that consists of a screen scintillator, a light intensifier, a video camera, a digitizing frame grabber and a computer. The device composed by the scintillator ...

2000-01-01

306

Preliminary study of metabolic radiotherapy with {sup 188}Re via small animal imaging  

Energy Technology Data Exchange (ETDEWEB)

{sup 188}Re is a {beta}{sup -} (Emax=2.12 MeV) and {gamma} (155 keV) emitter. Since its chemistry is similar to that of the largely employed tracer, {sup 99m}Tc, molecules of hyaluronic acid (HA) have been labelled with {sup 188}Re to produce a target specific radiopharmaceutical. The radiolabeled compound, i.v. injected in healthy mice, is able to accumulate into the liver after a few minutes. To study the effect of metabolic radiotherapy in mice, we have built a small gamma camera based on a matrix of YAP:Ce crystals, with 0.6x0.6x10 mm{sup 3} pixels, read out by a R2486 Hamamatsu PSPMT. A high-sensitivity 20 mm thick lead parallel-hole collimator, with hole diameter 1.5 mm and septa of 0.18 mm, is placed in front of the YAP matrix. Preliminary results obtained with various phantoms containing a solution of {sup 188}Re and with C57 black mice injected with the {sup 188}Re-HA solution are presented. To increase the space resolution and to obtain two orthogonal ...

2006-01-15

307

Neutron reflectometry study of surface segregation in an isotopic poly(ethylene propylene) blend : deviation from mean field theory.  

Energy Technology Data Exchange (ETDEWEB)

Neutron reflectometry (NR) was used to measure the concentration profile of a symmetric PEP/dPEP polymer blend with nanometer-scale resolution in the one-phase region. The shape of the profile near the surface was found to differ significantly from mean-field theory predictions for all bulk concentrations and temperatures surveyed. The profile shape is flattened at the surface over a distance about half the bulk correlation length, a length scale far greater than that of the dispersive forces that are the dominant microscopic interaction in such blends. We introduce a new method for extracting the surface energy difference that drives segregation based on the Gibbs adsorption equation (GAE) and compare it to a previous method based on mean-field theory. While both methods produce qualitatively similar results (the surface energy of pure dPEP is {approx}0.21 mJ/m{sup 2} smaller than pure PEP), the GAE method is much less model dependent, requiring knowledge of only ...

1995-12-04

308

Modification of ink-jet paper by oxygen-plasma treatment  

International Nuclear Information System (INIS)

A study on oxygen-plasma treatment of ink-jet paper is presented. Paper was exposed to a weakly ionized, highly dissociated oxygen plasma with an electron temperature of 5 eV, a positive-ion density of 8 x 1015 m-3 and a density of neutral oxygen atoms of 5 x 1021 m-3. Optical emission spectroscopy (OES) was applied as a method for detection of the reaction products during the plasma treatment of the paper. OES spectra between 250 and 1000 nm were measured continuously during the plasma treatment. The wettability of the samples before and after the plasma treatment was determined by measuring the contact angle of a water drop. The appearance of the surface-functional groups was determined by using high-resolution x-ray photoelectron spectroscopy (XPS), while changes in the surface morphology were monitored with scanning electron microscopy (SEM). Already after 1 s of the plasma treatment the surface, which was originally hydrophobic, changed to ...

2007-06-21

309

In vivo footprinting of the human [alpha]-globin locus upstream regulatory element by guanine and adenine ligation-mediated polymerase chain reaction  

Energy Technology Data Exchange (ETDEWEB)

A major regulatory element required for expression of the human [alpha]-globin genes is located 40 kb upstream of the embryonic [zeta]-globin gene. To understand how this and other locus control region (LCR) elements contribute to high-level expression in erythroid cells, we have performed high-resolution, in vivo dimethyl sulfate footprinting. In addition, we have modified the dimethyl sulfate-based ligation-mediated polymerase chain reaction in vivo footprinting procedure to permit the assessment of interactions at guanine and adenine residues, rather than guanines alone. In vivo footprinting of the human [alpha]-LCR element carried on chromosome 16 in a mouse erythroleukemia cell environment revealed protein occupancy at GATA-1, AP-1/NF-E2, and CACC/GGTGG motifs, specific differences compared with in vitro protein binding, and distinct changes in one region upon dimethyl sulfoxide-induced cellular maturation. No protein contacts were detected in nonexpressing ...

1992-05-01

310

Fred C. Cuny Memorial Continuing Education Series. Lesson 10: group dynamics in disasters: managing work groups.  

Science.gov (United States)

Groups are assigned or formed to perform tasks that one person cannot accomplish alone. This lesson describes the classification of work groups, group unity, leadership, motivation, recognition, conflict resolution, and remediation associated with managing groups and their activities. Advantages associated with group process include 1) the generation of better ideas, 2) ability to assume greater risks; make fewer errors; 3) the capacity for greater knowledge and 4) information, and for some problems, production of better decisions. Groups may be formal or informal. Formal groups may be organic, task-directed, or committees. Informal groups arise when it becomes obvious that a group will work better or may be formed by a discipline within the organization or through friendships. The size of the group its status within the organization, the goals established, and the dependence of the members on the group all may affect the cohesiveness of the group. Leadership of ...

311

Decoherence, chaos, quantum-classical correspondence and the arrow of time  

Energy Technology Data Exchange (ETDEWEB)

The environment - external or internal degrees of freedom coupled to the object of interest - can, in effect, monitor some of its observables. As a result, the eigenstates of these observables decohere and behave like classical states. Continuous destruction of superpositions leads to the effective environment-induced superselection (einselection), which is beginning to be recognized as a key step in the transition from quantum to classical. We investigate it here in the context of quantum chaos. I show that the evolution of a chaotic macroscopic system is not just difficult to predict (requiring accuracy exponentially increasing with time) but quickly ceases to be deterministic in principle as a result of the Heisenberg uncertainty (which limits the available resolution). This happens after a time t{sub {Dirac_h}} which is only logarithmic in the Planck constant. For example, various components of the solar system are chaotic, with the Lyapunov timescales ranging ...

1998-12-01

312

Critical current measurements of high Tc superconductors in a scanning low temperature cryostat  

Energy Technology Data Exchange (ETDEWEB)

Maintaining uniformity of properties over long distances is one of the fabrication problems encountered with the new high {Tc} superconductors. Uniform properties are crucial in long tapes or wires with high critical current since local nonuniformities can limit the current carrying capacity of the whole piece. Transport critical currents in high {Tc} superconductors are conventionally measured with the contact 4-point probe DC current-voltage technique. This technique requires contact with the sample and and spatially averages over the region between the two voltage contacts. Two techniques have been used to infer the critical state model. The first uses the net magnetization of a suitably shaped sample in an external magnetic field. The second combines a DC magnetic field with AC induced currents to infer spatial flux profiles. The AC magnetization technique offers an advantage in that it is noncontacting; however, it also averages the measurement over a large area and requires that ...

1991-01-01

313

Characterization of a time-of-flight mass spectrometer and its applications in the study of solid surfaces; Charakterisierung eines Flugzeitmassenspektrometers und seine Anwendungen in der Festkoerperoberflaechenuntersuchung  

Energy Technology Data Exchange (ETDEWEB)

The object and the purpose of the present work was to develop, to assemble and to start running a new TOF (time of flight) mass spectrometer for imaging SNMS analytic which is optimized for the analysis of highly molecular secondary ions. The most important purpose was the characterization of the TOF mass spectrometer. The obtained mass spectra of indium, tantalum and silver clusters reflect the excellent properties of the TOF mass spectrometer for the detection of large clusters with good detection efficiency up to masses of 16000 amu. The possibility of the deflection of selected saturated atom and cluster peaks serves for further improvement of the detection efficiency for large molecules. The accessible mass resolution was determined to be of the order of m/{delta}m=1000 in the high mass region. Numerous measurements were carried out to characterize the useful yield of this spectrometer. For a best possible adaptation of the TOF mass spectrometer for the ...

2006-12-21

314

Assessment of detector sensitivity and uniformity during SPECT rotation  

International Nuclear Information System (INIS)

The purpose of this research was to: a) evaluate variations in sensitivity and uniformity of SPECT detectors during 360"0 rotation, b) explore the causes of the variations and c) to discuss a correction procedure. A flood source consisting of a lucite disc 47.7 cm in diameter containing 3 microcuries of Co-57 was constructed. This source can be firmly attached to the uncollimated detector guaranteeing no detector-source geometry change during rotation. Four different SPECT cameras were tested. Measurements were obtained at 45"0 intervals throughout a 360"0 rotation, and repeated in 3 different orientations with respect to the earth's magnetic field. In one camera the effects of the direction and strength of induced magnetic fields were studied. All detectors showed cyclic rotational variations in sensitivity; in three cameras 6%, in one 3%. The amplitude and phase of the sensitivity variation curves and the variations in uniformity were unique for each camera. The detector's degree of ...

1984-06-05

315

A unified framework for capturing facial images in video surveillance systems using cooperative camera system  

Science.gov (United States)

Low resolution and un-sharp facial images are always captured from surveillance videos because of long human-camera distance and human movements. Previous works addressed this problem by using an active camera to capture close-up facial images without considering human movements and mechanical delays of the active camera. In this paper, we proposed a unified framework to capture facial images in video surveillance systems by using one static and active camera in a cooperative manner. Human faces are first located by a skin-color based real-time face detection algorithm. A stereo camera model is also employed to approximate human face location and his/her velocity with respect to the active camera. Given the mechanical delays of the active camera, the position of a target face with a given delay can be estimated using a Human-Camera Synchronization Model. By controlling the active camera with corresponding amount of pan, tilt, and zoom, a clear ...

2008-04-01

316

Visual mental imagery during caloric vestibular stimulation  

UK PubMed Central (United Kingdom)

We investigated high-resolution mental imagery and mental rotation, while the participants received caloric vestibular stimulation. High-resolution visual mental imagery tasks have been shown...Full Text Available

2006-01-01

317

Phantom and animal imaging studies using PLS synchrotron X-rays  

CERN Document Server

Ultra-high resolution radiographs can be obtained using synchrotron X-rays. A collaboration team consisting of K-JIST, POSTECH and YUMC has recently commissioned a new beamline (5C1) at Pohang Light Source (PLS) in Korea for medical applications using phase contrast radiology. Relatively simple image acquisition systems were set up on 5C1 beamline, and imaging studies were performed for resolution test patterns, mammographic phantom, and animals. Resolution test patterns and mammographic phantom images showed much better image resolution and quality with the 5C1 imaging system than the mammography system. Both fish and mouse images with 5C1 imaging system also showed much better image resolution with great details of organs and anatomy compared to those obtained with a conventional mammography system. A simple and inexpensive ultra-high resolution imaging system ...

2001-01-01

318

Nuclear magnetic resonance imaging of hepatic focal injuries with phased array antennae surface: apnoea or high resolution imagery?  

International Nuclear Information System (INIS)

French English ... Orig. Title Imagerie IRM des lesions focales hepatiques avec les antennes de surface en reseau phase (phased array): apnee ou imagerie haute resolution?.

1995-10-26

319

Multi-focal optical-resolution photoacoustic microscopy in vivo  

UK PubMed Central (United Kingdom)

Although ultrasound arrays were exploited in photoacoustic imaging to improve imaging speed, ultrasound-array-based optical-resolution photoacoustic microscopy (OR-PAM) has never been achieved...Full Text Available

2011-04-01

320

Investigation of the hadronic final state in electron-proton interactions at HERA  

Energy Technology Data Exchange (ETDEWEB)

The main subject of this thesis is the study of the hardronic final state in deep-inelastic electron-proton scattering. Theexperiment described in this thesis is performed with such a high resolution that the substructure of the proton is probed by the electron beam with a resolution of less than 10{sup -15} cm. (orig./HSI).

1995-09-18

321

High-resolution infrared observations in IC 5146  

Energy Technology Data Exchange (ETDEWEB)

High-resolution near-infrared and far-infrared observations are presented of the southeastern molecular cloud fragment in the IC 5146 dark cloud. These observations rule out earlier suggestions for the formation of massive stars in this fragment.

1984-04-01

322

High-Speed Ultrahigh-Resolution Optical Coherence Tomography Findings in Chronic Solar Retinopathy  

UK PubMed Central (United Kingdom)

PurposeTo describe ocular findings for a 34-year-old man with chronic solar retinopathy using high-speed ultrahigh-resolution (UHR) optical coherence tomography (OCT).Full Text Available

2008-01-01

323

High speed optical coherence microscopy with autofocus adjustment and a miniaturized endoscopic imaging probe  

UK PubMed Central (United Kingdom)

Optical coherence microscopy (OCM) is a promising technique or high resolution cellular imaging in human tissues. An OCM system for high-speed en face cellular resolution imaging...Full Text Available

2010-03-01

324

Changes in Gingival Crevicular Fluid Inflammatory Mediator Levels during the Induction and Resolution of Experimental Gingivitis in Humans  

UK PubMed Central (United Kingdom)

AimThe goal of this study is to characterize the changes in 33 biomarkers within the gingival crevicular fluid during the 3-week induction and 4-week resolution of...Full Text Available

2010-04-01

325

An automated procedure for detecting protein folds from sub-nanometer resolution electron density  

UK PubMed Central (United Kingdom)

The use of sub-nanometer resolution electron density as spatial constraints for denovo and ab-initio structure prediction requires knowledge of protein boundaries...Full Text Available

2010-06-01

326

A non-local approach for image super-resolution using intermodality priors ?  

UK PubMed Central (United Kingdom)

Image enhancement is of great importance in medical imaging where image resolution remains a crucial point in many image analysis algorithms. In this paper, we investigate brain hallucination...Full Text Available

2010-08-01

327

SAMS Research and Development  

Science.gov (United States)

... resolution video. RESULTS Statistics describing the typical inertial navigation error growth were collected. Typical errors ...

2008-08-06

329

Nuclear structure physics at high resolution  

Energy Technology Data Exchange (ETDEWEB)

Techniques for studying nuclear structure are reviewed. Examples are given of charge density determinations by electron and proton inelastic scattering. (AIP)

1985-04-01

330

High Resolution Mesoscale Weather Data Improvement to ...  

Science.gov (United States)

... that defines hydrometeor categories for the duration of the simulation ... and to observe the movement of any particular system ... particle settling occurred ...

2007-03-01

331
332

Detection and Diagnosis of Oral Neoplasia with an Optical ...  

Science.gov (United States)

... Thus, 0CM provides the potential to image epithelial tissue with the subcellular resolution needed to assess the pathologic state of tissue. ...

333

C-CAP Land Cover, Maui, Hawaii 2006  

Science.gov (United States)

This data set consists of land derived from high resolution imagery and was analyzed according to the Coastal Change ... ...

334

Alignment accuracy of focused ion beam implantation  

Energy Technology Data Exchange (ETDEWEB)

The theoretical alignment limit for focused ion beam (FIB) implantation was deduced from the calculated resolution for the detection of an alignment mark. The alignment resolution varies with the signal to noise ratio and there is an optimum current which gives the best resolution. The alignment resolution epsilon/sub sigma/ is approximately 0.006 ..mu..m for a 160 keV Si/sup ++/ beam from our FIB implanter. The measured alignment error is approximately 0.06 ..mu..m and the main reason of this discrepancy is vibration. The ultimate limit on the alignment error can be reached through improvements in the implanter system.

1987-06-01

336

Coulomb Repulsion in Miniature Ion Mobility Spectrometry  

Energy Technology Data Exchange (ETDEWEB)

We have undertaken a study of ion mobility resolution in a miniature ion mobility spectrometer with a drift channel 1.7 mm in diameter and 35 mm in length. The device attained a maximum resolution of 14 in separating ions of NO, O{sub 2}, and methyl iodine. The ions were generated by pulses from a frequency-quadrupled Nd:YAG laser. Broadening due to Coulomb repulsion was modeled theoretically and shown experimentally to have a major effect on the resolution of the miniature device.

1999-08-08

337

High resolution sequence stratigraphy in China  

International Nuclear Information System (INIS)

Since high resolution sequence stratigraphy was introduced into China by DENG Hong-wen in 1995, it has been experienced two development stages in China which are the beginning stage of theory research and development of theory research and application, and the stage of theoretical maturity and widely application that is going into. It is proved by practices that high resolution sequence stratigraphy plays more and more important roles in the exploration and development of oil and gas in Chinese continental oil-bearing basin and the research field spreads to the exploration of coal mine, uranium mine and other strata deposits. However, the theory of high resolution sequence stratigraphy still has some shortages, it should be improved in many aspects. The authors point out that high resolution sequence stratigraphy should be characterized quantitatively and modelized by computer techniques. (authors)

2008-11-01

338

Change in HER-2/neu Status from Negative to Positive following Treatment in Breast Cancer: A Case Report  

UK PubMed Central (United Kingdom)

IntroductionApproximately 25–30% of breast cancers are assumed to be HER-2/neu positive. It is well known that HER-2/neu-positive cancers after treatment with trastuzumab...Full Text Available

339

Capacity of staphylococci to grow in the presence of ovotransferrin or CrCl3 as a character of potential pathogenicity.  

UK PubMed Central (United Kingdom)

A total of 150 strains of staphylococci, clinically isolated, were tested for sensitivity to ovotransferrin (conalbumin). Among these, all the 50 coagulase-positive, mannitol-positive, and deoxyribonuclease-positive...Full Text Available

1980-05-01

340

Truth Breakers  

British Library Electronic Table of Contents (United Kingdom)

Philosophical semantics requires an ontology that includes negative as well as positive states of affairs as truth-makers and truth-breakers. Theories that try to do without negative states of affairs while interpreting propositional truth as positive correspondence with existent states of affairs are inherently inadequate and incomplete. A semantics and ontology of negative states of affairs can also do justice to positive states of affairs, since the iterated negative state of affairs that a negative state of affairs exists describes a positive state of affairs, but the iterated positive state of affairs that a positive state of affairs exists never describes a negative state of affairs. Negative states of affairs are not only essential to semantics, but to a complete description of the ...

2010-01-01

341

Polyurethane - positioning aids in radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

A simple and cheap method is described for the manufacturing of individual positioning aids made of foamed polyurethane. Some examples are given to demonstrate the applicability of these positioning aids for the irradiation of different body regions. The reproducibility of the radiation field in the head and neck area was investigated with and without positioning aid. It was proved that the field is adjusted more exactly when positioning aids are applied. The dosimetric investigations performed showed a negligible influence of foamed polyurethane on the radiation quality. So the positioning aids could be left within the radiation field when drawing the field borders.

1985-06-01

342

Magnetic resonance imaging. Handbook and atlas; Kernspintomographie. Kompendium und Atlas  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging (MRI) as a diagnostic imaging tool relies on the generation of magnetic fields, whereas the computerized tomography (CT) uses X-radiation. The fundamental principle of MRI is the magnetic resonance of paramagnetic atomic nuclei. These nuclei, as e.g. protons (= hydrogen nuclei), are aligned in required orientation by application of a strong magnetic field. Upon simultaneous application of an electromagnetic high-frequency field perpendicular to the axis of the basic magnetic field, and in response to periodical changing of the electromagnetic field at a given frequency, the originally aligned paramagnetic nuclei are forced into a movement similar to that of a ``whipping top``. When the resonance frequency is shut off, the nuclei return to their former, aligned positions, inducing a weak signal in a coil. The series of signals generated by multiple repetition of this process of excitation of nuclei and their return to aligned rest is used ...

1999-10-01

343

A thermal-hydraulic drift-flux based mixture-fluid model for the description of single- and two-phase flow along a general coolant channel  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows: Different to the very simple class of homogeneous non-equilibrium models (HEM) an one dimensional thermal-hydraulic theoretical drift-flux based and thus non-homogeneous coolant channel model and, as a result, an in itself complete thermal-hydraulic coolant channel module CCM have been established allowing to simulate in a very general way the steady state and transient behaviour of the most important parameters of a single- or two-phase fluid flowing within any type of heated or non-heated coolant channel (with an eventually varying cross flow area). To avoid mathematical discontinuities at the transition from single- to two-phase flow the coolant channel will, in its general form, be split into different regions, i.e. be looked as a basic channel (BC) which can consist of a number of different flow regimes and can, accordingly, be subdivided into a number of sub-channels (SC-s). All of them belong, obviously, to only two types of SC-s, a SC with an ...

2005-07-01

344

Visualization of strong around motion calculated from the numerical simulation of Hyogo-ken Nanbu earthquake; Suchi simulation de miru Hyogoken nanbu jishin no kyoshindo  

Energy Technology Data Exchange (ETDEWEB)

Hyogo-ken Nanbu earthquake with a focus in the Akashi straits has given huge earthquake damages in and around Awaji Island and Kobe City in 1995. It is clear that the basement structure, which is steeply deepened at Kobe City from Rokko Mountains towards the coast, and the focus under this related closely to the local generation of strong ground motion. Generation process of the strong ground motion was discussed using 2D and 3D numerical simulation methods. The 3D pseudospectral method was used for the calculation. Space of 51.2km{times}25.6km{times}25.6km was selected for the calculation. This space was discretized with the lattice interval of 200m. Consequently, it was found that the basement structure with a steeply deepened basement, soft and weak geological structure thickly deposited on the basement, and earthquake faults running under the boundary of base rock and sediments related greatly to ...

1996-10-01

345

Validation of the 3D finite element transport theory code EVENT for shielding applications  

Energy Technology Data Exchange (ETDEWEB)

This paper is concerned with the validation of the 3D deterministic neutral-particle transport theory code EVENT for shielding applications. The code is based on the finite element-spherical harmonics (FE-P{sub N}) method which has been extensively developed over the last decade. A general multi-group, anisotropic scattering formalism enables the code to address realistic steady state and time dependent, multi-dimensional coupled neutron/gamma radiation transport problems involving high scattering and deep penetration alike. The powerful geometrical flexibility and competitive computational effort makes the code an attractive tool for shielding applications. In recognition of this, EVENT is currently in the process of being adopted by the UK nuclear industry. The theory behind EVENT is described and its numerical implementation is outlined. Numerical results obtained by the code are compared with predictions of the Monte Carlo code MCBEND and ...

2000-03-01

346

VIBA-LAB2: a virtual ion beam analysis laboratory software package incorporating elemental map simulations  

International Nuclear Information System (INIS)

The software package VIBA-lab1, which incorporates PIXE and RBS energy spectra simulation has now been extended to include the simulation of elemental maps from 3D structures. VIBA-lab1 allows the user to define a wide variety of experimental parameters, e.g. energy and species of incident ions, excitation and detection geometry, etc. When the relevant experimental parameters as well as target composition are defined, the program can then simulate the corresponding PIXE and RBS spectra. VIBA-LAB2 has been written with applications in nuclear microscopy in mind. A set of drag-and-drop tools has been incorporated to allow the user to define a three-dimensional sample object of mixed elemental composition. PIXE energy spectra simulations are then carried out on pixel-by-pixel basis and the corresponding intensity distributions or elemental maps can be computed. Several simulated intensity distributions for some ...

1999-09-02

347

The effects of spatially distributed ionisation sources on the temperature structure of HII region  

CERN Document Server

Spatially resolved studies of star forming regions show that the assumption of spherical geometry is not realistic in most cases, with a major complication posed by the gas being ionised by multiple non-centrally located stars or star clusters. We try to isolate the effects of multiple non-centrally located stars on the temperature and ionisation structure of HII regions, via the construction of 3D photoionisation models using the 3D Monte Carlo photoionisation code MOCASSIN. We find that the true temperature fluctuations due to the stellar distribution (as opposed to the large-scale temperature gradients due to other gas properties) are small in all cases and not a significant cause of error in metallicity studies. Strong emission lines from HII regions are often used to study the metallicity of star-forming regions. We compare integrated emission line spectra from our models and quantify any ...

2007-01-01

348

Seismic tomography inversion in the case that sources and receivers are distributed out of a 2-D plane; Shingen jushinten ga nijigen heimennai ni nai baai no danseiha tomography kaiseki ni kansuru kosatsu  

Energy Technology Data Exchange (ETDEWEB)

In the case where sources and receivers are not distributed on a 2-D plane, seismic tomography inversion was studied. In tomography experiments, the existing wells are generally used. In such case, sources and receivers are frequently not distributed on a 2-D plane. The 2.5-D analysis method including 2-D structure and 3-D ray-tracing was thus developed. This method is featured by less memory necessary for ray-tracing calculation, and the same algorithm for velocity determination as 2-D analysis method. In previous methods, since analysis is generally carried out by projecting sources and receivers on a certain assumed 2-D plane, it can derive correct results in the case of constant velocity and straight ray, however, in the other case, it derives incorrect results. Application of 3-D tomography requires a large amount of memory, and falls into poor convergence because of various parameters. The 2.5-D ...

1996-10-01

349

Results of 3-dimensional structural FE-modeling of the coil end-regions of the LHC main dipoles  

CERN Document Server

The transition region between the straight part and the ends of the coils of the LHC model and prototype dipole magnets are often identified as the origin of training quenches. In order to study how the discontinuities in the material properties of these regions affect coil pre-stress and possibly gain more insight in the quench behavior, a program was set up at CERN to analyze by 3D-FEM these particular regions. The ACCEL team, who performed a similar analysis for the main quadrupoles of the Superconducting Supercollider SSC, is entrusted with this program. In this paper we report on the results of 3D-modeling and analysis of the coil return end region, including the complete coil mass, of a 1-m single bore model magnet. This magnet represents all relevant features of the "two-in-one" LHC main dipole design concerning the winding configuration, the collar pack, the yoke, and the outer shell ...

2000-01-01

350

Physically based modelling of damage, amorphization, and recrystallization for predictive device-size process simulation  

Energy Technology Data Exchange (ETDEWEB)

Current advanced CMOS source/drain engineering involves the use of amorphizing implants with 3D geometry. Upon annealing, the induced transient enhanced diffusion (TED) can only be accurately predicted if the amorphized region is correctly modeled, as well as the formation and evolution of extended defects, particularly 3 1 1's and dislocation loops. In addition to the extended defects, already modeled in the atomistic kinetic Monte-Carlo simulator DADOS, we have developed a physically based modeling approach for the implant-induced damage build-up, amorphization and recrystallization, suitable to handle device-size process simulation. It is based on amorphous pockets (3D, irregular shape agglomerates of an arbitrary number of interstitials and vacancies, plus trapped impurities) with a size-dependent activation energy for recombination. The model is able to reproduce experimental aspects like ...

2004-12-15

351

Physically based modelling of damage, amorphization, and recrystallization for predictive device-size process simulation  

International Nuclear Information System (INIS)

Current advanced CMOS source/drain engineering involves the use of amorphizing implants with 3D geometry. Upon annealing, the induced transient enhanced diffusion (TED) can only be accurately predicted if the amorphized region is correctly modeled, as well as the formation and evolution of extended defects, particularly 3 1 1's and dislocation loops. In addition to the extended defects, already modeled in the atomistic kinetic Monte-Carlo simulator DADOS, we have developed a physically based modeling approach for the implant-induced damage build-up, amorphization and recrystallization, suitable to handle device-size process simulation. It is based on amorphous pockets (3D, irregular shape agglomerates of an arbitrary number of interstitials and vacancies, plus trapped impurities) with a size-dependent activation energy for recombination. The model is able to reproduce experimental aspects like the ...

2004-12-15

352

Phenomenological 3D and 1D consistent models for shape-memory alloy materials  

Science.gov (United States)

The paper deals with the modeling and the development of a numerical procedure for the analysis of shape-memory alloy (SMA) elements in order to predict the main features of SMA devices. A 3D SMA model in the framework of small strain theory is developed starting from the thermo-mechanical model proposed by Souza et al. (Eur J Mech A/Solids 17:789-806, 1998) and modified by Auricchio and Petrini (Int J Numer Methods Eng 55:1255-1284, 2002). The aim of this paper is to propose some more modifications to the original model, to derive its consistent 1D formulation, to clarify the mechanical meaning of the material parameters governing the constitutive model. A robust time integration algorithm is developed in the framework of the finite element method and a new beam finite element is proposed. Some numerical applications and a comparison with experimental data available in literature are carried out in order to assess the ability of the proposed ...

2009-08-01

353

Numerical flow simulation in ship and ocean engineering; Senpaku kaiyo suiri bun`ta deno ryutai suchi simulation  

Energy Technology Data Exchange (ETDEWEB)

The improvement in the functions of the viscous flow calculation method VEGA-SHIP around a ship and the expansion of application range were described as the numerical flow simulation in ship and ocean engineering and at the same time application examples to the ocean engineering by the general-purpose flow simulation code FLOW-3D handling the non-steady flow with a free surface were introduced as the numerical simulation regarding such products as a water gate and a dam. In the VEGA-SHIP, water surface was handled as a fixed wall so that wave could not be calculated. Therefore, an algorithm for calculating wave on the water surface was added to the VEGA-SHIP and a calculation method simultaneously considering the creation of wave around the ship and viscosity was developed. The FLOW-3D was used to calculate the phenomenon where inside liquid moved greatly due to the oscillation of a tank and hit against ...

1995-01-01

354

NMR in highly correlated superconductors  

International Nuclear Information System (INIS)

Results of our systematic NMR study in high T_c cuprates are reviewed. The antiferromagnetic spin fluctuations (AFSF) decrease in the order of La_1_._8_5Sr_0_._1_5CuO_4. YBa_2Cu_3O_7 and Tl_2Ba_2CuO_6_+_y. 1/T_1 of "6"3Cu in the CuO_2 plane in the normal state follows essentially a Curie-Weiss law at high temperature and T_1T = const. law at low temperature. The temperature dependence of 1/T_1 and the Knight shift together with their impurity effect in the superconducting state strongly suggest d-wave pairing implying the AFSF to be responsible for the occurrence of superconductivity. From the NQR frequency measurement the density of Cu 3d and O 2p holes decreases and increases, respectively, in the order of La, Y and Tl compounds, which is consistent with the change of AFSF. The relation between T_c and #nu#_Q, and their pressure dependence suggest that there exists and optimum value of the ratio of Cu ...

1992-08-01

355

K{beta}-to-K{alpha} X-ray intensity ratio studies on the changes of valence electronic structures of Ti, V, Cr, and Co in their disilicide compounds  

Energy Technology Data Exchange (ETDEWEB)

K{beta}-to-K{alpha} X-ray intensity ratios of Ti, V, Cr, and Co in pure metals and their disilicide compounds have been measured following excitation by 59.54 keV {gamma}-rays from a 200 mCi {sup 241}Am point-source. The K{beta}-to-K{alpha} intensity ratios of all these metals in the disilicide compounds are found to be less than the corresponding ratios for pure metals. Comparison of the measured K{beta}-to-K{alpha} intensity ratios for the disilicides and pure metals with the multiconfiguration Dirac-Fock calculations indicates increase of the 3d electron populations of Ti, V, Cr, and Co in the disilicides from their pure metal values suggesting the rearrangement of electrons between 3d and 4s states of the individual metal atom. This rearrangement is found to be opposite to that observed in our previously reported work on NiSi{sub 2} and CuSi{sub 2}.

1999-06-01

356

K#beta#-to-K#alpha# X-ray intensity ratio studies on the changes of valence electronic structures of Ti, V, Cr, and Co in their disilicide compounds  

International Nuclear Information System (INIS)

K#beta#-to-K#alpha# X-ray intensity ratios of Ti, V, Cr, and Co in pure metals and their disilicide compounds have been measured following excitation by 59.54 keV #gamma#-rays from a 200 mCi "2"4"1Am point-source. The K#beta#-to-K#alpha# intensity ratios of all these metals in the disilicide compounds are found to be less than the corresponding ratios for pure metals. Comparison of the measured K#beta#-to-K#alpha# intensity ratios for the disilicides and pure metals with the multiconfiguration Dirac-Fock calculations indicates increase of the 3d electron populations of Ti, V, Cr, and Co in the disilicides from their pure metal values suggesting the rearrangement of electrons between 3d and 4s states of the individual metal atom. This rearrangement is found to be opposite to that observed in our previously reported work on NiSi_2 and CuSi_2.

1999-06-01

357

Investigation of local-dimensional galvanic distortion on MT data in the central part of Northeastern Japan; Tohoku chiho no MT data ni mirareru kyokushoteki sanjigensei no eikyo  

Energy Technology Data Exchange (ETDEWEB)

Groom-Bailey decomposition analysis was carried out to investigate regional 3-D galvanic distortion on MT data in the central part of Northeastern Japan. Measuring sites were located nearly along the east-west line crossing Northeastern Japan. Three measuring lines (A, B, C) from the north to the south were prepared, and only data on the C line were analyzed in this paper. As a result, twist and shear were estimated to be not zero depending on local distortion in most of the sites. It was thus clarified that this method is not always perfect. This method was effective for regional 2-D structures, however, its application was doubtful to complicated 3-D underground structures in Japan. In order to obtain more accurate results, 2-D analysis using the impedance including no local distortion effect was necessary after the preliminary Groom-Bailey decomposition analysis. The direction of the wide area ...

1996-10-01

358

Influence of Ce0.9Gd0.1O2-d particles on microstructure and oxygen permeability of Ba0.5Sr0.5Co0.8Fe0.2O3-d composite membrane  

British Library Electronic Table of Contents (United Kingdom)

This study examined the oxygen permeation behavior of Ce0.9Gd0.1O2-d (Gadolinium-Doped Ceria, GDC)/Ba0.5Sr0.5Co0.8Fe0.2O3-d (BSCF) composite membranes fabricated using a conventional sintering technique. GDC/BSCF composite membranes with a relative density >95% could be obtained when a green compact of BSCF and GDC was sintered at 1150^oC for 5h. It appears that GDC serves as a grain growth inhibitor because the average grain size of the composite decreased with increasing GDC content. The oxygen permeability of the BSCF and GDC/BSCF composite membranes strongly depends on the grain size and membrane thickness. The addition of GDC to BSCF resulted in a small grain size, low thermal expansion coefficient and high hardness. However, it is believed that oxygen permeation was blocked by GDC, a...

2010-01-01

359

Feasibility study of large combined function magnets for the Jefferson lab 12 GeV upgrade  

CERN Document Server

The 12 GeV upgrade at Jefferson Lab has identified two new large spectrometers as Physics detectors for the project. The first is a 7.5 Gev/c 35 m-sr. spectrometer that requires a pair of identical Combined Function Superconducting Magnets (CFSM) that can simultaneously produce 1.5 T dipole fields and 4.5 T/m quadrupole fields inside a warm bore of 120cm. The second is an 11 GeV/c 2 m-sr. spectrometer that requires a CFSM that simultaneously produces a dipole field of 4.0 T and a quadruple field of 3.0 T/m in a 60 cm warm bore. Magnetic designs using TOSCA 3D have been performed to realize the magnetic requirements, provide 3d fields for optics analysis and produce field and force information for the engineering feasibility of the magnets. A two-sector cos( theta )/cos(2 theta ) design with a low nominal current density, warm bore and warm iron design has been selected and analyzed. These low current ...

2005-01-01

360

Direct observation of ordered orbital of YTiO_3 by the X-ray magnetic diffraction technique  

International Nuclear Information System (INIS)

X-ray magnetic diffraction (XMD) technique was applied to an orbital ordering compound of ferromagnetic YTiO_3 for the first time. The orbital-magnetic form factor #mu# _L(k) and the spin-magnetic form factor #mu# _S(k) were independently measured by utilizing the LS separation ability of the XMD. The #mu# _L(k) was measured for ten reciprocal-lattice points. No significant values of the #mu# _L(k) were observed for most of the reciprocal-lattice points within the estimated statistical errors, which suggested quenching of the orbital moment. The #mu# _S(k) was measured for 22 reciprocal-lattice points. Fourier synthesis of the #mu# _S(k) gave the spin density distribution m _S(r) in the real space. The obtained m _S(r) map shows the characteristic feature of the electron distribution of 3d electron in the t_2_g state of a Ti atom coordinated by O"2"- ions, in which the electrons are distributed away from the negative O"2"- ions. It is concluded ...

2005-08-01

361

Decay of the Ar 2s"-"1 and 2p"-"1 and Kr 3p"-"1 and 3d"-"1 hole states studied by photoelectron-ion coincidence spectroscopy  

International Nuclear Information System (INIS)

The decay channels of the Ar 2s"-"1 and 2p"-"1 and Kr 3p"-"1 and 3d"-"1 electronic hole states have been investigated by means of photoelectron-photoion coincidence measurements following innershell ionization using synchrotron radiation. With the method of final ion-charge resolving electron spectroscopy it has become possible to disentangle different contributions to the electron spectrum and to determine the decay probabilities P(nl"-"1#->#n+) of the above-mentioned hole states (nl"-"1) to the final ionic charge states n+. A high correlation with threefold or even fourfold charged ions has been found in all cases. Possible decay routes, via cascade or direct double Auger processes, are discussed on the basis of energy-level schemes calculated with the Hartree-Fock method. Special emphasis is laid on the examination of the Kr 3p"-"1 decay process, where the two fine-structure components (j=1/2,3/2) exhibit noticeably different decay ...

2002-04-01

362

Computational models of stellar collapse and core-collapse supernovae  

International Nuclear Information System (INIS)

Core-collapse supernovae are among Nature's most energetic events. They mark the end of massive star evolution and pollute the interstellar medium with the life-enabling ashes of thermonuclear burning. Despite their importance for the evolution of galaxies and life in the universe, the details of the core-collapse supernova explosion mechanism remain in the dark and pose a daunting computational challenge. We outline the multi-dimensional, multi-scale, and multi-physics nature of the core-collapse supernova problem and discuss computational strategies and requirements for its solution. Specifically, we highlight the axisymmetric (2D) radiation-MHD code VULCAN/2D and present results obtained from the first full-2D angle-dependent neutrino radiation-hydrodynamics simulations of the post-core-bounce supernova evolution. We then go on to discuss the new code Zelmani which is based on the open-source HPC Cactus framework and provides a scalable AMR approach for ...

2009-07-01

363

Boxy/peanut "bulges": comparing the structure of galaxies with the underlying families of periodic orbits  

CERN Document Server

The vertical profiles of disc galaxies are built by the material trapped around stable periodic orbits, which form their "skeletons". According to this, the knowledge of the stability of the main families of periodic orbits in appropriate 3D models, can predict possible morphologies for edge-on disc galaxies. In a pilot survey we compare the orbital structures which lead to the appearance of "peanuts" and "X"-like features with the edge-on profiles of three disc galaxies (IC 2531, NGC 4013 and UGC 2048). The subtraction from the images of a model representing the axisymmetric component of the galaxies reveals the contribution of the non-axisymmetric terms. We find a direct correspondence between the orbital profiles of 3D bars in models and the observed main morphological features of the residuals. We also apply a simple unsharp masking technique in order to study the sharpest features of the images. ...

2006-01-01

364

A widely tunable continuous-time LPF for a direct conversion DBS tuner  

Energy Technology Data Exchange (ETDEWEB)

A continuous-time 7th-order Butterworth Gm-C low pass filter (LPF) with on-chip automatic tuning circuit has been implemented for a direct conversion DBS tuner in 0.35 mum SiGe BiCMOS technology. The filter's -3 dB cutoff frequency f{sub 0} can be tuned from 4 to 40 MHz. A novel on-chip automatic tuning scheme has been successfully realized to tune and lock the filter's cutoff frequency. Measurement results show that the filter has -0.5 dB passband gain, +-5% bandwidth accuracy, 30 nV/Hz{sup 1/2} input referred noise, -3 dBVrms passband IIP3, and 27 dBVrms stopband IIP3. The I/Q LPFs with the tuning circuit draw 13 mA (with f{sub 0} = 20 MHz) from 5 V supply, and occupy 0.5 mm{sup 2}.

2009-02-15

365

Universal spectrochemical series of six-coordinate octahedral metal complexes for modifying the ligand field splitting.  

Science.gov (United States)

We studied a novel universal spectrochemical series of six-coordinated octahedral 3d transition metal complexes, which can be used for any combination of central metal atom and ligand molecules. A two dimensional spectrochemical series could be used to estimate the ligand field splitting energy of not only known compounds but also the unknown compounds. Therefore, it should be possible to control the physical properties, such as the electronic and magnetic properties and the optical phenomena of octahedral transition metal complexes by modifying the ligand field splitting. PMID:19378561

2009-01-28

366

The entropic boundary law in BF theory  

International Nuclear Information System (INIS)

We compute the entropy of a closed bounded region of space for pure 3d Riemannian gravity formulated as a topological BF theory for the gauge group SU(2) and show its holographic behavior. More precisely, we consider a fixed graph embedded in space and study the flat connection spin network state without and with particle-like topological defects. We regularize and compute exactly the entanglement for a bipartite splitting of the graph and show it scales at leading order with the number of vertices on the boundary (or equivalently with the number of loops crossing the boundary). More generally these results apply to BF theory with any compact gauge group in any space-time dimension.

2009-01-11

367

Simulation of the transient eddy current measurement for the characterization of depth and conductivity of a plate  

International Nuclear Information System (INIS)

A transient eddy current measurement method is presented to determine the thickness and conductivity of a conductive plate. The conductive plate is induced by an air-cored coil, the magnetic flux density along the axial is measured and the various signals corresponding to plates with different thickness and conductivity are calculated using a 3D transient eddy current simulator. Characteristic features are obtained from the transient response. A similarity-based modeling method is utilized in this study to estimate the thickness and conductivity of the conductive plate. (author)

2008-07-01

368

Scaling and performance of a 3-D radiation hydrodynamics code on message-passing parallel computers: final report  

Energy Technology Data Exchange (ETDEWEB)

This report details an investigation into the efficacy of two approaches to solving the radiation diffusion equation within a radiation hydrodynamic simulation. Because leading-edge scientific computing platforms have evolved from large single-node vector processors to parallel aggregates containing tens to thousands of individual CPU's, the ability of an algorithm to maintain high compute efficiency when distributed over a large array of nodes is critically important. The viability of an algorithm thus hinges upon the tripartite question of numerical accuracy, total time to solution, and parallel efficiency.

1999-10-28

369

Report of the Fluid Dynamics Panel Working Group 10 on calculation of 3D separate turbulent flows in boundary layer limit  

Science.gov (United States)

The results of a study conducted by Working Group 10 of the AGARD Fluid Dynamics Panel to investigate the limits of boundary layer methods, both the integral and field type formulations, for calculating three-dimensional turbulent separated flow are presented. Test cases used to assess the boundary layer calculations included the DFLVR prolate spheroid at angle of attack and the NASA-Ames Wing C. Comparisons between boundary layer calculations and experimental data are presented for these test cases along with observations, conclusions, and recommendations.

1990-05-01

370

Modified-VSIMM algorithm with an application to the naval fire control technology  

British Library Electronic Table of Contents (United Kingdom)

A modified variable structure interacting multiple model (M-VSIMM) estimator for complex hybrid maneuver target tracking is presented. The M-VSIMM could potentially be applied to fire control systems (FCS) used on warships. Target model groups were designed using 3D dimensional dynamic target models. Optimal model group selection logic was proposed, contrary to the activation and termination logic in the original VSIMM. The system will respond faster with optimal model group selection logic. After performing simulations, the tracking performances of the Kalman, ?-?(-?), VDIE, IMM and M-VSIMM filters were compared under various maneuvering conditions.

2011-01-01

371

Modern visualization of the liver with MRI - current trends and future perspectives; Moderne Leberbildgebung mit der MRT - aktuelle Trends und Zukunft  

Energy Technology Data Exchange (ETDEWEB)

This contribution provides an overview and imparts basic knowledge on pertinent technical developments in magnetic resonance imaging (MRI) of the liver: 3D sequences, respiratory triggering, parallel imaging, and 3 Tesla (3T). 3D sequences can be used as T1-weighted (T1w) sequences for analyzing dynamics of contrast enhancement or as T2w sequences for MR cholangiography. Consistent improvements in respiratory triggering make it possible to obtain good image quality on T2w scans even in patients unable to hold their breath. Parallel imaging as a universal technique to accelerate image acquisition is particularly appropriate for MRI of the liver, and it has been shown that the reduced acquisition time is not achieved at the expense of image quality. Further progress in MRI of the liver can be expected with use of the 3T systems, but hitherto irrelevant problems must still be solved. Overall the ...

2004-12-01

372

Modelling of Aquitaine II pipe whipping test with the EUROPLEXUS fast dynamics code  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a numerical simulation with the EUROPLEXUS fast dynamics software of a pipe whipping phenomenon occurring in the thermal hydraulic conditions of a loss of coolant accident in a PWR primary circuit. Different physical phenomena take place simultaneously during the rupture and the whipping of the pipe such as plasticity, contact, large displacements, two-phase flow regime and fluid structure interaction. Two kinds of numerical models - a simplified pipeline model and a mixed 1D/3D model - are considered and compared throughout modelling and computation. Numerical results are compared with experimental data belonging to the Aquitaine II test campaign.

2005-08-01

373

Modeling global atmospheric CO2 with improved emission inventories and CO2 production from the oxidation of other carbon species  

Energy Technology Data Exchange (ETDEWEB)

The use of global three-dimensional (3-D) models with satellite observations of CO2 in inverse modeling studies is an area of growing importance for understanding Earth s carbon cycle. Here we use the GEOS-Chem model (version 8-02-01) CO2 mode with multiple modifications in order to assess their impact on CO2 forward simulations. Modifications include CO2 surface emissions from shipping (0.19 PgC yr 1), 3-D spatially-distributed emissions from aviation (0.16 PgC yr 1), and 3-D chemical production of CO2 (1.05 PgC yr 1). Although CO2 chemical production from the oxidation of CO, CH4 and other carbon gases is recognized as an important contribution to global CO2, it is typically accounted for by conversion from its precursors at the surface rather than in the free troposphere. We base our model 3-D spatial distribution of ...

2010-01-01

374

Ion Transport Measurements in a Multi-Dipole Argon Plasma by Broadband Laser Induced Fluorescence  

International Nuclear Information System (INIS)

Argon ion laser induced fluorescence measurements were carried out in a multipolar filament discharge with a broadband diode laser centered on 668 nm, which stimulated a transition from the metastable state in Ar(II) 3d4F7/2 to 4p4D05/2. The intensity of the induced fluorescence at 442 nm was maximized by the optimization of the discharge parameters and the laser power. From the recovery of the background fluorescence after the laser was turned off, the ion diffusion coefficient was deduced and compared with the result inferred from the experiments of ion acoustic wave (IAW) damping.

2009-06-01

375

Investigation of Two-Phase Flow Regime Maps for Development of Thermal-Hydraulic Analysis Codes  

Energy Technology Data Exchange (ETDEWEB)

This reports is a literature survey on models and correlations for determining flow pattern that are used to simulate thermal-hydraulics in nuclear reactors. Determination of flow patterns are a basis for obtaining physical values of wall/interfacial friction, wall/interfacial heat transfer, and droplet entrainment/de-entrainment. Not only existing system codes, such as RELAP5-3D, TRAC-M, MARS, TRACE, CATHARE) but also up-to-date researches were reviewed to find models and correlations

2010-04-15

376

Formation and stability of self-assembled coherent islands in highly mismatched heteroepitaxy  

CERN Document Server

We study the energetics of island formation in Stranski-Krastanow growth within a parameter-free approach. It is shown that an optimum island size exists for a given coverage and island density if changes in the wetting layer morphology after the 3D transition are properly taken into account. Our approach reproduces well the experimental island size dependence on coverage, and indicates that the critical layer thickness depends on growth conditions. The present study provides a new explanation for the (frequently found) rather narrow size distribution of self-assembled coherent islands.

1999-01-01

377

Development of a chemically assisted micro-beam etching system for three-dimensional microanalysis  

Energy Technology Data Exchange (ETDEWEB)

A chemically assisted micro-beam etching system for 3D microanalysis was designed. Using chemically assisted ion beam etching (CAIBE) method with FIB shave-off scanning, about several hundred micrometers clean cross-section will be acquired in a few hours. We use focused ion beam (FIB) and electron beam (EB) as micro-beams, halogen or halide mainly as reactive gases. The apparatus was manufactured based on this concept. We found that the FIB, Q-MS and SED worked as expected. The instrumentation has been completed.

2003-01-15

378

Determination of the Venezuelan coastal-zone wind atlas by using numerical methods  

Energy Technology Data Exchange (ETDEWEB)

This work deals with the development of wind maps in the Venezuelan coastal zones (South America). The Navier-Stokes equations for real viscous incompressible flow are discretized via the finite element method and they are applied to a full 3D numerical model. Two regions were analyzed: the Margarita island and the Paraguana peninsula, both of them located in the Caribbean Sea at the North of Venezuela. These regions were modeled by using a three dimensional control volume, discretized through hexaedric eight-noded finite elements. Some wind maps obtained in this research are presented and discussed. (author)

1995-12-31

379

Design and Testing of Superconducting Microwave Passive Components for Quantum Information Processing  

CERN Document Server

We report on the design, fabrication and testing of two superconducting passive microwave components, a quadrature hybrid and a 20 dB directional coupler. These components are designed to be integrated with superconducting qubits or Josephson parametric amplifiers and used in quantum information processing applications. For the coupler, we measure return loss and isolation > 20 dB, and insertion loss 20 dB and insertion loss < 0.3 dB in a 10% band around 6.5 GHz. These values are within the design specifications of our application; however, we find a 7% difference between the designed and measured center frequency for the hybrid.

2010-01-01

380

Billion particle linac simulations for future light sources  

Energy Technology Data Exchange (ETDEWEB)

In this paper we report on multi-physics, multi-billion macroparticle simulation of beam transport in a free electron laser (FEL) linac for future light source applications. The simulation includes a self-consistent calculation of 3D space-charge effects, short-range geometry wakefields, longitudinal coherent synchrotron radiation (CSR) wakefields, and detailed modeling of RF acceleration and focusing. We discuss the need for and the challenges associated with such large-scale simulation. Applications to the study of the microbunching instability in an FEL linac are also presented.

2008-09-25

381

A spatial damage energy distribution calculation for ion-implanted materials  

International Nuclear Information System (INIS)

A simple method allowing easy calculation of the spatial damage energy distributions for ion-implanted materials is presented. The direct procedure takes account of the variation with depth of the lateral spreading of implanted ions, as well as the effects of energy transport by the recoiling target atoms. The subsequent computer program LUPIN-3D provides three-dimensional damage distributions and allows the construction of damage energy mappings. Various substrates of technological interest are investigated and several fields of application of the calculation are envisaged. The density of cascades can therefore be determined and heterogeneous amorphization models can be implemented. (orig.).

1989-01-01

382

A new technique for radon measurement based on a combination of a track-etch detector and activated charcoal  

Energy Technology Data Exchange (ETDEWEB)

A new technique for radon measurement in the natural environment was investigated. It is based on the use of activated charcoal and a track-etch detector. The charcoal acts as a radon collector from the air and the track-etch detector as a recorder of the alpha particles emitted by radon and its decay products. Our preliminary results show that the response of the new dosimeter to radon, using Deodorant activated charcoal (TOK, Yugoslavia) and a CR-39 track-etch detector, is 1.4 tracks cm{sup -2}/Bqm{sup -3}d, which is about eight times higher than that obtained with a standard track-etch dosimeter. (author).

1991-01-01

383

A Preliminary Analysis of SMART Reactor Core Using the COREDAX Code  

International Nuclear Information System (INIS)

The 3-D neutronics code COREDAX has been developed based on AFEN (Analytic Function Expansion Nodal) method for x-y-z geometry and for hex-z geometry. In this study, the COREDAX code, as a regulatory review tool independent of the designer's, was applied to the SMART reactor core that was designed by KAERI (Korea Atomic Energy Research Institute). For nuclear cross section generation, the HELIOS lattice code was used in this study. The preliminary results for steady state in various conditions are presented in this paper

2010-10-01

384

Valence-electron configuration of Ti and Ni in Ti{sub x}Ni{sub 1-x} alloys from K{beta}-to-K{alpha} X-ray intensity ratio studies  

Energy Technology Data Exchange (ETDEWEB)

K{beta}-to-K{alpha} X-ray intensity ratios of Ti and Ni have been measured in pure metals and in alloys of Ti{sub x}Ni{sub 1-x} (x=0.7, 0.6, 0.5, 0.4 and 0.3) following excitation by 22.69 keV X-rays from a 10 mCi {sup 109}Cd radioactive point source. The valence-electron configurations of these metals were determined by corporation of measured K{beta}-to-K{alpha} X-ray intensity ratios with the results of multiconfiguration Dirac-Fock calculation for various valence-electron configurations. Valence-electron configurations of 3d-transition metals in alloys indicate significant differences with respect to the pure metals. Our analysis indicates that these differences arise from delocalization and/or charge transfer phenomena in alloys. Namely, the observed change of the valence-electron configurations of metals in alloys can be explained with the transfer of 3d electrons from one element to the other ...

2010-06-15

385

Three-dimensional rotational angiography of the carotid arteries with high-flow injection from the aortic arch. Preliminary experience  

International Nuclear Information System (INIS)

Purpose: Three-dimensional rotational angiography (3DRA) is a new technique based on a rotational angiographic acquisition able to display arterial vessels in a 3D rendering mode. The system was mainly developed for neuroradiological evaluations but preliminary extracranial experiences have also been reported. The aim of our work was to compare the results of three-dimensional angiography of the carotid arteries done with high-flow injection of contrast medium from the aortic arch with the results of selective angiography. Materials and methods: Twenty patients underwent digital angiography of the supra-aortic vessels in order to quantify a stenosis of the carotid bifurcations previously detected at Doppler Ultrasound. Examinations were performed with the Philips Integris Allura system provided with the rotational angiography (RA) tool connected to a workstation for three-dimensional reconstruction able to display vessels in a ...

386

Root-knot nematode management in double-cropped plasticulture vegetables.  

Science.gov (United States)

Combination treatments of chisel-injected fumigants (methyl bromide, 1,3-D, metam sodium, and chloropicrin) on a first crop, followed by drip-applied fumigants (metam sodium and 1,3-D +/- chloropicrin) on a second crop, with and without oxamyl drip applications were evaluated for control of Meloidogyne incognita in three different tests (2002 to 2004) in Tifton, GA. First crops were eggplant or tomato, and second crops were cantaloupe, squash, or jalapeno pepper. Double-cropped vegetables suffered much greater root-knot nematode (RKN) pressure than first crops, and almost-total yield loss occurred when second crops received no nematicide treatment. On a first crop of eggplant, all fumigants provided good nematode control and average yield increases of 10% to 15 %. On second crops, higher application rates and fumigant combinations (metam sodium and 1,3-D +/- ...

2006-03-01

387

Non-selective cervical and cerebral three-dimensional rotational angiography  

International Nuclear Information System (INIS)

To evaluate the usefulness of three-dimensional (3D) rotational angiography, cervical carotid or cerebral angiography was done without catheterizing the branches of the thoracic aorta. A 5-Fr pig-tail type catheter was passed into the ascending aorta via the radial artery or the femoral artery. Optimal carotid angiogram views were obtained using approximately 45 ml of contrast medium at a flow rate of 15 ml/sec. Optimal cerebral angiogram views were obtained using approximately 70 ml of contrast medium at a flow rate of 20 ml/sec. The contrast medium concentration was 300 to 350 mgI/ml. A satisfactory view could be obtained in 5 of 8 (63%) cases on cervical carotid 3D angiography and in 8 of 14 (57%) cases on cerebral 3D angiography. In all cases, no complications were noted. This method offers the advantages of requiring a relatively short procedure time and a ...

2007-09-01

388

Multislice helical CT in the diagnosis of hilar cholangiocarcinoma  

International Nuclear Information System (INIS)

Objective: To investigate the value ofMSCT in observing the direct findings of hilar cholangiocarcinoma1Methods Multislice helical CT studies were performed on the upper abdomen in 19 consecutive patientswith painless jaundice1 Precontrast and dynamic contrast enhanced (25 s phase and 60 s phase) scanswere conducted, and 3D imageswere reconstructed using enhanced raw data in 15 cases1 The direct CT findings of hilar cholangiocarcinoma were studied by three radiologists respectively in a 32scale strategy1 The morphological features and extension of bile duct involvement by hilar cholangiocarcinoma were analyzed1 All the 19 caseswere pathologically p roved as hilar cholangiocarcinoma by surgery (15 cases) and ERCP ( 4 cases) 1 Results The direct findings and extension of hilar cholangiocarcinoma could be demonstrated in 14 out of 15 3D reconstruction images, 8 out of 19 in 25 s phase, and 7 out of 19 in ...

2005-11-01

389

Introducing DeBRa: a detailed breast model for radiological studies  

Energy Technology Data Exchange (ETDEWEB)

Currently, x-ray mammography is the method of choice in breast cancer screening programmes. As the mammography technology moves from 2D imaging modalities to 3D, conventional computational phantoms do not have sufficient detail to support the studies of these advanced imaging systems. Studies of these 3D imaging systems call for a realistic and sophisticated computational model of the breast. DeBRa (Detailed Breast model for Radiological studies) is the most advanced, detailed, 3D computational model of the breast developed recently for breast imaging studies. A DeBRa phantom can be constructed to model a compressed breast, as in film/screen, digital mammography and digital breast tomosynthesis studies, or a non-compressed breast as in positron emission mammography and breast CT studies. Both the cranial-caudal and mediolateral oblique views can be modelled. The ...

2009-07-21

390

Incompatibility of metam sodium with halogenated fumigants.  

Science.gov (United States)

Metam sodium (metam) is a widely used soil fumigant. Combined application of metam and other available fumigants is intended to produce synergic pesticidal effects for a broad spectrum of pest control in soil fumigation. This study aimed to test the compatibility of metam with the halogenated fumigants 1,3-dichloropropene (1,3-D), chloropicrin, methyl bromide, methyl iodide and propargyl bromide. Halogenated fumigants and metam were spiked simultaneously into organic solvents, water and moist soils, and metam-induced degradation of these halogenated chemicals was evaluated. In all three media, the halogenated fumigants were incompatible with metam and degraded via rapid chemical reactions. The degradation rate varied with halogenated fumigant species and increased as the amount of metam present was increased. In moist soil, 15-95% of the halogenated fumigants were decomposed within 72 h by metam at a 1:1 molar ratio. Combined application of ...

2005-05-01

391

Evaluation of Ordos Basin in China  

Energy Technology Data Exchange (ETDEWEB)

Ordos basin lies in the north-central China, in a compression tectonic regime, with an area of approximately 250,000 km{sup 2}, including several pay zones ranging from Cambrian to Jurassic. It is one of the earliest-formed marine to continental-superimposed basin in China, characterized by Proterozoic basin-marginal rifling and Lower-Paleozoic carbonate platform development followed by western thrusting and foreland depression during Mesozoic. It underwent several tectonic movements and is covered by several structural layers, with many play types developed, primarily thrust and anticlinal plays in the west, and differential compaction (river-channel sand lens) or drape as well as buried hill plays in the basin center and east. Ordos basin is a prolific gas basin with an estimated resource potential of gas 656,091 billion m{sup 3} in the Paleozoic strata and oil 2.0474 billion tons in the Mesozoic strata. In 1986, in the western part of the basin, the well Tian-1 on the Tianchi ...

1996-06-01

392

Concurrent and adjuvant docetaxel with three-dimensional conformal radiation therapy plus androgen deprivation for high-risk prostate cancer: Preliminary results of a multicentre phase II trial  

International Nuclear Information System (INIS)

Background and purpose: We evaluate the feasibility of concomitant and adjuvant docetaxel combined with three-dimensional conformal radiotherapy (3D-CRT) and androgen deprivation in high-risk prostate carcinomas. Methods: Fifty men with high-risk localized prostate cancer (16), locally advanced (28) or very high-risk prostate cancer (6) were included. Seventy Gy were delivered on prostate and seminal vesicles in 35 fractions, concurrently with weekly docetaxel (20 mg/m"2). Three weeks after the completion of 3D-CRT, docetaxel was given for 3 cycles (60 mg/m"2), every 3 weeks. Patients had to receive LHRH agonist during 3 years. Results: The intent to treat analysis shows that four patients out of 15 stopped prematurely the chemotherapy due to grade 3-4 acute toxicity. In the per protocol analysis, 46 patients completed a full-dose chemoradiation regimen representing 413 cycles: five patients experienced ...

2010-11-01

393

Comparison of stereotactic radiosurgery and fractionated stereotactic radiotherapy of acoustic neurinomas according to 3-D tumor volume shrinkage and quality of life  

International Nuclear Information System (INIS)

Background and purpose: stereotactic radiosurgery (SRS) and also fractionated stereotactic radiotherapy (SRT) offer high local control (LC) rates (> 90%). This study aimed to evaluate three-dimensional (3-D) tumor volume (TV) shrinkage and to assess quality of life (QoL) after SRS/SRT. Patients and methods: from 1999 to 2005, 35/74 patients were treated with SRS, and 39/74 with SRT. Median age was 60 years. Treatment was delivered by a linear accelerator. Median single dose was 13 Gy (SRS) or 54 Gy (SRT). Patients were followed up ? 12 months after SRS/SRT. LC and toxicity were evaluated by clinical examinations and magnetic resonance imaging. 3-D TV shrinkage was evaluated with the planning system. QoL was assessed using the questionnaire Short Form-36. Results: Median follow-up was 50/36 months (SRS/SRT). Actuarial 5-year freedom from progression/overall survival was 88.1%/100% (SRS), and ...

2009-09-01

394

Calculation of the output power in self-amplified spontaneous radiation using scaling of power with number of simulation particles  

International Nuclear Information System (INIS)

Recent advances in self-amplified spontaneous emission (SASE) experiments stimulate interest in quantitative comparison of measurements with theory. In this paper we show that the widely used simulation code TDA3D, developed by Tran and Wurtele [Comput. Phys. Commun. 54, 263 (1989)] even though a single frequency code, can be used to determine the output power in the SASE process with excellent approximation in the exponential growth regime. The method applies when the gain is not very high, which is a special advantage, because when the gain is not very high, the analytical calculation is particularly difficult since the exponential growing term does not dominate. The analysis utilizes a scaling relation between the output power and the number of simulation particles in the code TDA3D: left-angle P right-angle=N_#lambda#"'/N_#lambda# left-angle P"'right-angle, where left-angle P right-angle is the ...

1998-10-01

400

An Explanation for Positive Differential dc Voltage-Current Characteristics in Weakly Ionized, Low-Pressure Positive Column Gas Discharge Plasmas  

Energy Technology Data Exchange (ETDEWEB)

A physical explanation is given for the positive differential voltage-current characteristic seen at low current in weakly ionized, low-pressure positive column discharges in argon/mercury gas mixtures. {copyright} {ital 1996 The American Physical Society.}

1996-07-01

402

On the relationship between stacking process and resolution. 2; Jugo shori to bunkaino ni kansuru kiso kenkyu. 2  

Energy Technology Data Exchange (ETDEWEB)

With respect to concept of resolution in seismic exploration using the reflection method, detailed considerations were given on processes of forming the resolution as a result of arranging observation points at vibration transmitting and receiving points. In the discussion, numerical experiments were carried out, in which the scattering stacking process is applied in a model having one scatterer existing in homogeneous media. The experiments investigated an imaging formation process of the scatterer when arrangement of the vibration transmitting and receiving points were changed from a coarse condition to a dense condition while the number of transmitting and receiving points is being increased. Resolution is created if waveforms having finite frequencies are used as input, and the imaging is performed by utilizing the limited number of vibration receiving and transmitting points. If the concept of equi-travel plane is used ...

1997-05-27

403

Transmutations in fusion test facilities  

Science.gov (United States)

Using an expanded nuclear data base, the transmutation of PCA, AMCR33 (a reduced activation austenitic steel), HT-9, Rafer2 (a reduced activation ferritic steel), V-15%Cr-5%Ti alloy, and SiAlON (a ceramic) were calculated for two positions in the Fast Flux Test Facility (FFTF), three positions in the High Flux Isotope Reactor (HFIR), and the first wall position of both the STARFIRE and MARS conceptual fusion reactors. The peripheral test (PTP) position, and to a lesser extent the radial beryllium (RB) position, of HFIR show significant transmutations which are often in the opposite direction to the transmutations in the fusion conceptual designs. The positions in FFTF, as well as the hafnium covered location in the HFIR RB position show relative minor transmutations.

1986-04-01

404

Toll-like receptor 2 polymorphism and gram-positive bacterial infections after liver transplantation  

British Library Electronic Table of Contents (United Kingdom)

Abstract Toll-like receptor 2 (TLR2) is an immune sensor for gram-positive bacterial cell wall components. Single-nucleotide polymorphisms (SNPs) in the TLR2 gene that impair its function may, therefore, influence the risk and outcomes of gram-positive bacterial infections. In a cohort of 694 liver transplant recipients, we assessed the TLR2 SNP that is translated into an amino acid substitution of arginine for glutamine at position 753 (R753Q), and we found that its presence was associated with the clinical characteristics and outcomes of gram-positive bacterial infections. The proportions of patients with the TLR2 R753Q SNP did not significantly differ between those with gram-positive bacterial infections and those without gram-positive bacterial infections (9.6% versus 9.6%, P = 0.999)....

2011-01-01

405

Study on high-resolution sequence stratigraphy framework of uranium-hosting rock series in Qianjiadian sag  

International Nuclear Information System (INIS)

The ore-hosting Yaojia Formation is composed of a set of braided stream medium-fine grained sediments. Guided by the basic theory of high-resolution sequence stratigraphy, and based on the core observation, the analysis of chemical composition of rocks, and data of natural potential logging and apparent resistivity logging, the authors have set up the high-resolution sequence stratigraphy framework of the ore-hosting Yaojia Formation, and discussed the relation of the stratigraphic structure of the middle cycle, as well as the paleotopography, the micro-facies to the formation of uranium deposit. (authors)

2005-07-01

406

RAPID DAMAGE ASSESSMENT FROM HIGH RESOLUTION IMAGERY  

Energy Technology Data Exchange (ETDEWEB)

Disaster impact modeling and analysis uses huge volumes of image data that are produced immediately following a natural or an anthropogenic disaster event. Rapid damage assessment is the key to time critical decision support in disaster management to better utilize available response resources and accelerate recovery and relief efforts. But exploiting huge volumes of high resolution image data for identifying damaged areas with robust consistency in near real time is a challenging task. In this paper, we present an automated image analysis technique to identify areas of structural damage from high resolution optical satellite data using features based on image content.

2008-07-01

407

Development of high resolution imaging detectors for X-ray astronomy  

Energy Technology Data Exchange (ETDEWEB)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-03-01

408

Development of high resolution imaging detectors for X-ray astronomy  

International Nuclear Information System (INIS)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-01-01

409

The cross sections of (n, x) nuclear reactions on Pb and Bi at the neutron energy 14.6 MeV  

International Nuclear Information System (INIS)

... compton spectrometers cross sections energy resolution energy-level transitions

2000-06-14

410

Synthesizer Stability Evaluation - NASA Technical Report Server (NTRS)  

Science.gov (United States)

verified via high-resolution spectral density measurements using the Hadamard Variance. .... spectral density measurements were made with the HF5390 ...

411

Simultaneous recognition and segmentation of cells: application in C.elegans  

UK PubMed Central (United Kingdom)

Motivation: Automatic recognition of cell identities is critical for quantitative measurement, targeting and manipulation of cells of model animals at single-cell resolution. It has been...Full Text Available

2011-10-15

412

Self-similarity in NMR Spectra: An Application in Assessing the Level of Cysteine  

UK PubMed Central (United Kingdom)

High resolution of NMR spectroscopic data of biosamples are a rich source of information on the metabolic response to physiological variation or pathological events. There are many advantages...Full Text Available

2010-01-01

413

Science Directed Spacecraft Autonomy for Mars Missions - detail  

Science.gov (United States)

The rapidly growing field of remote sensing is beginning to supply massive amounts of high resolution imagery of the earth and other planets. ...

414

Resolution studies of a GEM-based TPC  

Energy Technology Data Exchange (ETDEWEB)

Currently there are four different concept studies trying to optimise the detector for the requirements at the ILC. In three of these detector concepts a time projection chamber (TPC) is foreseen as the main tracking device. To achieve the intended spatial resolution of 100 {mu}m, micro pattern gas detectors (MPGD) are considered for gas amplification. The two different MPGDs discussed for the ILC TPC are Micro-Mesh Gaseous Detectors (Micromegas) and Gas Electron Multiplier foils (GEMs). The current thesis shows resolution studies with a TPC prototype equipped with a triple GEM readout structure. A hodoscope made up of silicon strip sensors gives a precision reference track, allowing an unbiased measurement of the spatial resolution. High statistics measurements have been conducted at the DESY test beam facility, which provides positrons with a tunable energy between 1 GeV and 6 GeV. Using the independent measurement of the ...

2006-12-15

415

Postfire soil burn severity mapping with hyperspectral image unmixing  

Science.gov (United States)

Sep 28, 2011... to assess the application of high resolution imagery for burn severity mapping and to compare it to standard burn severity mapping methods. ...

416

PROBING NEAR-SURFACE ATMOSPHERIC TURBULENCE WITH LIDAR MEASUREMENTS AND HIGH-RESOLUTION HYDRODYNAMIC MODELS  

Energy Technology Data Exchange (ETDEWEB)

As lidar technology is able to provide fast data collection at a resolution of meters in an atmospheric volume, it is imperative to promote a modeling counterpart of the lidar capability. This paper describes an integrated capability based on data from a scanning water vapor lidar and a high-resolution hydrodynamic model (HIGRAD) equipped with a visualization routine (VIEWER) that simulates the lidar scanning. The purpose is to better understand the spatial and temporal representativeness of the lidar measurements and, in turn, to extend their utility in studying turbulence fields in the atmospheric boundary layer. Raman lidar water vapor data collected over the Pacific warm pool and the simulations with the HIGRAD code are used for identifying the underlying physics and potential aliasing effects of spatially resolved lidar measurements. This capability also helps improve the trade-off between spatial-temporal resolution ...

2000-11-01

418

NASA Satellite Measures Deforestation : Image of the Day  

Science.gov (United States)

Sep 14, 2005 ... For decades, the Brazilian government has been basing estimates of Amazon deforestation on high-resolution Landsat satellite data. Having ...

419

N-Body Code with Adaptive Mesh Refinement  

CERN Document Server

We have developed a simulation code with the techniques which enhance both spatial and time resolution of the PM method for which the spatial resolution is restricted by the spacing of structured mesh. The adaptive mesh refinement (AMR) technique subdivides the cells which satisfy the refinement criterion recursively. The hierarchical meshes are maintained by the special data structure and are modified in accordance with the change of particle distribution. In general, as the resolution of the simulation increases, its time step must be shortened and more computational time is required to complete the simulation. Since the AMR enhances the spatial resolution locally, we reduce the time step locally also, instead of shortening it globally. For this purpose we used a technique of hierarchical time steps (HTS) which changes the time step, from particle to particle, depending on the size of the cell in ...

2001-01-01

421

High resolution (p,p') reactions on "8"7Sr and "8"8Sr  

International Nuclear Information System (INIS)

... levels excited states mev range 10-100 proton reactions proton spectra protons

422

High Resolution Modeling of Coastal Inundation: User ...  

Science.gov (United States)

... Ruth. Preller@nrlssc.navy.mil 76 Marine Technology Society Journal Page 4. ... 78 Marine Technology Society Journal Page 6. ...

2007-07-27

423

Clinical spectrum  

Energy Technology Data Exchange (ETDEWEB)

A tunable diode laser is used to obtain infrared spectra of carbon dioxide in biological materials. The spectral resolution is sufficient to readily distinguish differing isotopic species. The technique may prove useful in clinical tests.

1987-11-01

424

Chronic Disability Syndrome  

UK PubMed Central (United Kingdom)

Prolonged disability is best understood as an illness that exists independently of the initiating disease. The disabled individual goes through predictable stages of disability before resolution occurs....Full Text Available

1991-09-01

425

C-CAP Land Cover, Commonwealth of the Northern Mariana Islands (CNMI), Farallon de Pajaros, 2004  

Science.gov (United States)

This data set consists of land derived from high resolution imagery and was analyzed according to the Coastal Change ... ...

426

C-CAP Land Cover, Commonwealth of the Northern Mariana Islands (CNMI), Anatahan, 2005  

Science.gov (United States)

This data set consists of land derived from high resolution imagery and was analyzed according to the Coastal Change ... ...

427

C-CAP Land Cover, Commonwealth of the Northern Mariana Islands (CNMI), Aguijan, 2003  

Science.gov (United States)

This data set consists of land derived from high resolution imagery and was analyzed according to the Coastal Change ... ...

428

Benefits of Using the Photosimulation Laboratory Environment ...  

Science.gov (United States)

... with the ability to capture imagery in raw 24-bit format, combined with large memory storage devices enable high resolution imagery to be captured ...

2002-08-01

429

Acquisition of a High Resolution Field Emission Scanning Electron Microscope for the Analysis of Returned Samples  

Science.gov (United States)

This grant furnished funds to purchase a state-of-the-art scanning electron microscope (SEM) to

2003-01-01

430

APOD: April 25, 1996 - In the Center of the Whirlpool  

Science.gov (United States)

picture will download the highest resolution version available. In the Center of the Whirlpool Credit: N. Panagia (STScI, ESA), NASA Explanation: In the center of M51, a spiral...

2011-10-07

431

APOD: 2011 June 11 - Supernovae in the Whirlpool  

Science.gov (United States)

the picture will download the highest resolution version available. Supernovae in the Whirlpool Image Credit & Copyright: R Jay Gabany Explanation: Where do spiral galaxies keep...

2011-10-07

432

APOD: 2009 May 26 - Whirlpool Galaxy Deep Field  

Science.gov (United States)

Clicking on the picture will download the highest resolution version available. Whirlpool Galaxy Deep Field Credit & Copyright: Jon Christensen Explanation: Follow the handle...

2011-10-07

433

APOD: 2005 November 25 - Moon Over Antarctica  

Science.gov (United States)

on the picture will download the highest resolution version available. Moon Over Antarctica Credit & Copyright: James Behrens (IGPP, Scripps Institution of Oceanography)...

2011-10-14

434

APOD: 2002 July 10 - M51: Cosmic Whirlpool  

Science.gov (United States)

on the picture will download the highest resolution version available. M51: Cosmic Whirlpool Credit & Copyright: Tony and Daphne Hallas Explanation: Follow the handle of the Big...

2011-10-07

435

APOD: 2000 July 24 - M51: The Whirlpool Galaxy  

Science.gov (United States)

on the picture will download the highest resolution version available. M51: The Whirlpool Galaxy Credit & Copyright: Todd Boroson (NOAO), AURA, NOAO, NSF Explanation: The...

2011-10-07

436

A setup for high-resolution isotope shift measurements on unstable lithium isotopes  

Energy Technology Data Exchange (ETDEWEB)

We present a laser spectroscopic approach for measuring the charge radius of the halo nucleus {sup 11}Li and report on recent progress in the development of the experimental apparatus.

2003-05-01

437

49 CFR 240.405 - Processing qualification review petitions.  

Science.gov (United States)

...Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION QUALIFICATION AND CERTIFICATION OF LOCOMOTIVE ENGINEERS Dispute Resolution Procedures § 240.405 Processing qualification review petitions. (a)...

2010-10-01

438

2010 NASA Terrestrial Ecology Science Team Meeting - NASA Carbon ...  

Science.gov (United States)

The biomass maps were compared with the U.S. Forest Service biomass map for 2002 , LVIS height data, and estimates from high resolution imagery. ...

439

2002 C-CAP Land Cover, Territory of American Samoa, Swains  

Science.gov (United States)

This data set consists of land derived from high resolution imagery and was analyzed according to the Coastal Change ... ...

440

Final Technical Report  

Energy Technology Data Exchange (ETDEWEB)

Installation of new Shortwave Spectrometer for permanent operation at SGP - In May 2006 the new ShortWave Spectrometer (SWS) was installed in the Optical Trailer at the Southern Great Plains Central Facility SGP on 27 April 2006. The SWS began full operation 28 April 2006 and has run continuously to the present. Over 25 GB of spectra has been collected, calibrated and archived. 3-D radiative transfer simulations - Retrieved fields of cloud optical thickness and effective radius to from the MODIS Airborne Simulator were used to reproduce 3D cloud fields that were used a input to 3D radiative transfer simulations and then compared with simultaneous Solar Spectral Flux Radiometer (SSFR) spectral irradiance measurements. The influence of both horizontal and vertical cloud structure, using accurate versus approximated optical properties in the radiative transfer ...

2009-05-26

441

3D transient calculations of PGV-1000 based on TRAC  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows: During calculations of SAR accidents and transients it is necessary to perform steam generator simulation. Best accuracy is 3D transient calculations presented in report. Main outcomes of work was next: 1. There was shown by analysis the applicability of code TRAC (Los-Alamos laboratory) for thermal - hydraulic calculations of horizontal steam generator PGV-1000M. Special nodalization scheme was developed for it purposes. 2. Validation and selection of thermal-hydraulic correlations for improvement of using the code at calculation PGV-1000M were performed. As result Labuntsov formula is recommended for horizontal SG. 3. Calculations of nominal mode operation of PGV-1000M for cross-verification with code STEG (Electrogorsk Research and Engineering Center EREC) during its verification were performed. Solution by TRAC was obtained for transient problem after stabilization time. 4. Development of dynamic SG model ...

2005-07-01

442

Performance of a large Bragg-curve spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A large Bragg-curve spectrometer has been constructed and tested. The detector has a cylindrical geometry and operates with a homogeneous electric field. Energy resolutions of <0.8% and Z resolutions of Z/..delta..Z=80 have been achieved for eleastically scattered /sup 58/Ni ions. These results demonstrate the suitability of this large solid-angle detector for use in a wide variety of heavy-ion scattering experiments.

1987-04-01

443

Performance of a large Bragg-curve spectrometer  

International Nuclear Information System (INIS)

A large Bragg-curve spectrometer has been constructed and tested. The detector has a cylindrical geometry and operates with a homogeneous electric field. Energy resolutions of <0.8% and Z resolutions of Z/#DELTA#Z=80 have been achieved for eleastically scattered "5"8Ni ions. These results demonstrate the suitability of this large solid-angle detector for use in a wide variety of heavy-ion scattering experiments. (orig.).

444

Metabolomics in Lung Inflammation: A High Resolution 1H NMR Study of Mice Exposed to Silica Dust  

UK PubMed Central (United Kingdom)

Here we report the first 1H NMR metabolomics studies on excised lungs and bronchoalveolar lavage fluid (BALF) from mice exposed to crystalline silica. High resolution 1H...Full Text Available

2008-01-01

445

High-resolution primary ion beam probe for SIMS  

Energy Technology Data Exchange (ETDEWEB)

High-brightness negative ion beams, especially O{sup -} beams, from a compact gaseous plasma source are studied to evaluate the suitability for high-resolution SIMS. Ion-optical calculations are made using the beam parameters from the new source. Results suggest that sub-100 nm spot with O{sup -} beam current of 10 pA is achievable. Beam focusing, the resulting beam current distributions at the target and the expected instrumental performance are discussed.

2004-06-15

446

High resolution neutron imaging of water in the polymer electrolyte fuel cell membrane  

Energy Technology Data Exchange (ETDEWEB)

Water transport in the ionomeric membrane, typically Nafion{reg_sign}, has profound influence on the performance of the polymer electrolyte fuel cell, in terms of internal resistance and overall water balance. In this work, high resolution neutron imaging of the Nafion{reg_sign} membrane is presented in order to measure water content and through-plane gradients in situ under disparate temperature and humidification conditions.

2009-01-01

447

High resolution imagery of the clumpy irregular galaxy Markarian 325 = NGC 7673  

Energy Technology Data Exchange (ETDEWEB)

High resolution imagery of the clumpy irregular galaxy Mkn 325 shows that some clumps have sizes approximately 300 pc while some may still be unresolved and approximately < 100 pc. In spite of dimensions comparable to - or even smaller than - those of the giant H II complex 30 Doradus, one clump has a star formation rate 100 times higher.

1982-05-01

448

High resolution imagery of the clumpy irregular galaxy Markarian 325 = NGC 7673  

International Nuclear Information System (INIS)

High resolution imagery of the clumpy irregular galaxy Mkn 325 shows that some clumps have sizes approximately 300 pc while some may still be unresolved and approximately < 100 pc. In spite of dimensions comparable to - or even smaller than - those of the giant H II complex 30 Doradus, one clump has a star formation rate 100 times higher. (author).

449

Field-portable lensfree tomographic microscope.  

Science.gov (United States)

We present a field-portable lensfree tomographic microscope, which can achieve sectional imaging of a large volume (?20 mm(3)) on a chip with an axial resolution of Hymenolepis nana egg, which is an infectious parasitic flatworm. Achieving a decent three-dimensional spatial resolution, this field-portable on-chip optical tomographic microscope might provide a useful toolset for telemedicine and high-throughput imaging applications in resource-poor settings. PMID:21573311

2011-05-16

450

Evaluation of peripheral vascular disease by intravenous digital subtraction angiography with the Fuji computed radiography (FCR) system  

Energy Technology Data Exchange (ETDEWEB)

Intravenous digital subtraction angiography using Fuji computed radiography system (FCR-DSA) was used to evaluate 57 preoperative patients with clinical manifestations of peripheral vascular disease of lower extremity. With its high contrast resolution and good special resolution, image of FCR-DSA could offer optimal information of vascular abnormality in lower extremity distal to midfoot for the diagnosis and the choice of management.

1987-03-01

451

Evaluation of peripheral vascular disease by intravenous digital subtraction angiography with the Fuji computed radiography (FCR) system  

International Nuclear Information System (INIS)

Intravenous digital subtraction angiography using Fuji computed radiography system (FCR-DSA) was used to evaluate 57 preoperative patients with clinical manifestations of peripheral vascular disease of lower extremity. With its high contrast resolution and good special resolution, image of FCR-DSA could offer optimal information of vascular abnormality in lower extremity distal to midfoot for the diagnosis and the choice of management. (orig.).

1987-01-01

452

Bragg curve spectroscopy detector for particle identification  

International Nuclear Information System (INIS)

The operation principle, construction and characteristics of the Bragg curve spectroscopy detector (BCS detector) are described. The electric field of the BCS detector is parallel to the particle trajectories. The detector was tested by 8.78 MeV and 6.02 MeV #alpha# particles from a ThC-ThC's source. The energy resolutions are 1.5% and 2.6% respectively for two groups of #alpha# particles, and the charge resolution is 2.7%. Further test experiments with heavy ions will be arranged.

453

A high-sensitivity small animal SPECT system  

International Nuclear Information System (INIS)

Medical imaging using single gamma-ray-emitting radionuclides typically makes use of parallel hole collimators or pinholes in order to achieve good spatial resolution. However, a tradeoff in sensitivity is inherent in the use of a collimator, and modern preclinical single photon emission computed tomography (SPECT) systems detect a very small fraction of emitted gamma rays, often less than 0.1%. A system for small animal SPECT imaging which uses no collimators could potentially achieve very high sensitivity-several tens of percent-with reasonably sized detectors. This would allow two significant improvements in preclinical studies: images could be obtained more rapidly, allowing higher throughput for screening applications, or for dynamic processes to be observed with very good time resolution; and images could be obtained with less radioactive tracer, making possible the in vivo imaging of low-capacity receptor systems, aiding research into ...

2009-03-07

454

Spherically bent crystal spectroscopy in laser-produced plasma  

International Nuclear Information System (INIS)

A curved crystal X-ray spectrographs of reflection type spherical geometry was required based on the Johann scheme. Due to their high efficiency and resolution, X-ray spectrographs of focusing spectrograph spatial resolution are suitable for detecting weak X-ray spectra in spectrometers for laser fusion research. Spherically bent mica crystal with a radius of curvature of 380 mm was used in the spectrometer. The Bragg angle of the crystal analyzer was 51 degree. The image plate was employed to obtain high spatial resolution and a narrow spectral band width, with an effective area of 30 mm x 80 mm. The designed optical path of the X-ray spectrometer beam was 980 mm long from the source to the crystal and the detector. The first experiment was carried out at the 20 J energy laser facility of Research Center of Laser Fusion, China Academy of Engineering Physics. X-ray spectra in an absolute intensity scale were obtained from ...

2008-02-01

455

High resolution Computed Tomography in the study of temporal bone trauma  

International Nuclear Information System (INIS)

Thirty-five patients with temporal bone fractures were examined; the fractures were sometimes associated with dislocation of the assicular chain caused by road fatalities. Computed Tomography (CT) was performed either because of the presence of clinical symptoms associated with trauma of the temporal bone, because of a hemotympanum discovered during a CT scan of the brain. Thirty-three fractures were detected: 19 longitudinal, 6 transverse, and 8 complex. An incudostapedial dislocation was also detected, together with a displacement of a stapedial prosthesis from the lenticular process of incus, and 3 incus-malleus dislocation associated with fractures. High resolution CT allows the precise definition of the course of the fractures, of the associated dislocation of the ossicular chain, and of facial nerve lesion, thus allowing a more accurate surgical intervention. In the examination of the temporal bone, high resolution CT is preferible to ...

1988-01-01

456

Time-Dependent Changes in Positively Biased Self-Perceptions of Children with ADHD: A Developmental Psychopathology Perspective  

UK PubMed Central (United Kingdom)

This study examined changes in the degree of positive bias in self-perceptions of previously-diagnosed 8 to 13 year-old children with attention-deficit/hyperactivity disorder (ADHD) (n=513)...Full Text Available

2010-05-01

457

Stopping or Reporting Early for Positive Results in Randomized Clinical Trials: The National Cancer Institute Cooperative Group Experience From 1990 to 2005  

UK PubMed Central (United Kingdom)

Randomized clinical trials are designed with stopping boundaries to guide data monitoring committees with their decision making concerning ongoing trials. In particular, when extremely positive results...Full Text Available

2009-04-01

458

Spoligotype Profile of Mycobacterium tuberculosis Complex Strains from HIV-Positive and -Negative Patients in Nigeria: a Comparative Analysis ?  

UK PubMed Central (United Kingdom)

We ran a comparative analysis of all patients for whom a positive culture of Mycobacterium tuberculosis complex was available between April 2004 and October 2005 and whose HIV serology...Full Text Available

2011-01-01

459

Sortases and the Art of Anchoring Proteins to the Envelopes of Gram-Positive Bacteria  

UK PubMed Central (United Kingdom)

The cell wall envelopes of gram-positive bacteria represent a surface organelle that not only functions as a cytoskeletal element but also promotes interactions between bacteria and their environment....Full Text Available

2006-03-01

460

Pretreatment with the gram-positive bacterial cell wall molecule peptidoglycan improves bacterial clearance and decreases inflammation and mortality in mice challenged with Pseudomonas aeruginosa  

UK PubMed Central (United Kingdom)

The objective of this study was to determine if inflammatory tolerance and enhancement of innate immune function could be induced by the gram-positive cell wall component peptidoglycan (PGN)....Full Text Available

2008-10-01

461

Isolation of gram-positive rods that resemble but are clearly distinct from Actinomyces pyogenes from mixed wound infections.  

UK PubMed Central (United Kingdom)

Beginning in 1990, gram-positive rods resembling Actinomyces pyogenes were found with increasing frequency in mixed cultures from various infectious processes, most of them from patients with otitis,...Full Text Available

1993-05-01

462

Genome-wide detection and characterization of positive selection in human populations  

UK PubMed Central (United Kingdom)

With the advent of dense maps of human genetic variation, it is now possible to detect positive natural selection across the human genome. Here we report an analysis of over 3 million polymorphisms...Full Text Available

2007-10-18

463

Flucytosine for treatment of Candida albicans in H1N1-positive patient  

UK PubMed Central (United Kingdom)

A 17-year-old H1N1-positive patient was successfully extubated after 25 days of ventilatory support for treatment of viral pneumonia which was complicated by empyema thoracis due to Candida...Full Text Available

2010-10-01

464

Effects of Intensity and Position Modulation On Switched Electrode Electronics Beam Position Monitor Systems at Jefferson Lab  

Energy Technology Data Exchange (ETDEWEB)

Two types of switched electrode electronics beam position monitors are in use at Jefferson Lab. Together they provide accurate beam position to the control system for beam intensities between 50 nA and 2 mA. One version, called the linac style, has a switching frequency of 125 kHz. The other, called the transport type, has a switching frequency of 7 kHz. The basic system provides information to the control system at a 1 Hz update rate. The systems are regularly used to measure the AC component of beam position and energy as well as suppress this motion as part of a fast feedback system. Position data produced by the system are also acquired on an event by event basis as part of the nuclear physics program in two of the experimental halls. This paper will focus on the AC characteristics of the system. These characteristics are affected by analog filter frequencies and a time delay between the measurement ...

2000-05-01

465

Driving with Hemianopia, II: Lane Position and Steering in a Driving Simulator  

UK PubMed Central (United Kingdom)

Purpose.The hypothesis that drivers with homonymous hemianopia (HH) would take a lane position that increased the safety margin on their blind side was tested with a driving simulator.Methods.Twelve...Full Text Available

2010-12-01

466

Control of wrist position and muscle relaxation by shifting spatial frames of reference for motoneuronal recruitment: possible involvement of corticospinal pathways  

UK PubMed Central (United Kingdom)

It has previously been established that muscles become active in response to deviations from a threshold (referent) position of the body or its segments, and that intentional motor actions result from...Full Text Available

2010-05-01

472

Low-lying positive-parity states in "1"0"1Tc  

International Nuclear Information System (INIS)

... beta decay energy levels energy-level transitions internal conversion

473

Automatic beam position control at Los Alamos Spallation Radiation Effects Facility (LASREF)  

Energy Technology Data Exchange (ETDEWEB)

Historically the Los Alamos Spallation Radiation Effects Facility (LASREF) has used manual methods to control the position of the 800 kW, 800 MeV proton beam on targets. New experiments, however, require more stringent position control more frequently than can be done manually for long periods of time. Data from an existing harp is used to automatically adjust steering magnets to maintain beam position to required tolerances.

1997-08-01

474

Uranium Mass and Isotopic Analysis. A new drum tomographic gamma scanning system  

Energy Technology Data Exchange (ETDEWEB)

The NIS-6 group at Los Alamos National Laboratory pioneered the development of Tomographic Gamma Scanning and continue to improve its utility in real measurement situations. Building on this experience we report the development of a state of the art TGS system suitable for industrial applications. The image reconstruction and visualization software has been integrated into the familiar Canberra NDA2000 software suite which also handles all other aspects of the data acquisition and management. In this paper we describe the salient design and performance parameters of the system. The application of gamma-ray tomography to safeguards for improved assay accuracy and knowledge confirmation is discussed. In particular we compare and contrast the relative merits of this TGS and a traditional Segmented Gamma Scanner and illustrate how the 3-D visualization of the TGS image can provide valuable additional information.

2003-05-01

475

Three-dimensional modeling of the flow and the interface surface in a continuous casting mold model  

Energy Technology Data Exchange (ETDEWEB)

A new methodology for three-dimensional (3-D) numerical modeling of the continuous steel casting process is presented and evaluated. The results are compared with available experimental data obtained in a water-oil mold model for various flow rates and immersion depths of the submerged entry nozzle. The water-oil interface pattern at the top of the mold is also investigated. Wave formation and evolution in time is simulated with a volume tracking method. The predicted flow field inside the mold exhibits quite satisfactory agreement with the corresponding measurements, whereas some quantitative differences are observed referring to the final wave amplitude at low casting speeds. Conclusions of scientific and engineering importance concerning both the computer algorithm and the mold performance are also drawn.

1999-12-01

476

TRIMPWR: A post processor for TRIMHX  

Energy Technology Data Exchange (ETDEWEB)

The TRIMPWR code has been developed as a post processor for TRIMHX (transient 3D diffusion code) in support of the reactor limits program. TRIMPWR is designed to produce JOSHUA files containing: core power as a function of time, assembly power by hex as a function of time, assembly power post peaking as a function of time, and axial power shapes for each assembly as a function of time (formatted for use by the FLOWTRAN code) from the output of a TRIMHX run. In an attempt to simplify the reactor limits process by reducing the number of assemblies which must be run through FLOWTRAN, TRIMPWR also sorts the assemblies by the product of the power post peaking and the maximum normalized axial power density for each assembly. This follows from the assumption that those assemblies having the maximum value of this product will have the most restrictive limits.

1989-11-01

477

Resonant frequencies and Q factors of dielectric parallelepipeds by measurement and by FDTD  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the measurement and computation of the resonant frequencies and the associated Q factors of dielectric parallelepipeds made of high-permittivity, low-loss ceramic materials. Each resonance peak is measured separately with a fine frequency step. A curve-fitting method is used to accurately estimate the resonant frequency and 3 dB bandwidth from the somewhat noisy measured data. The finite-difference time-domain method is used to compute the initial portion of the backscattered field due to a Gaussian pulse plane wave. The time response is then extended to zero value by Prony`s method. The measured and computed data is compared for a parallelepiped resonator of permittivity 37.84.

1994-12-31

478

Relativistic distorted-wave results for nickel-like gadolinium  

Science.gov (United States)

Electron collisional data are required for population kinetics modeling and spectral predictions of highly ionized ions in high-temperature plasmas. Nickel-like ions are especially interesting for their potential use in soft X-ray laser schemes pumped by electron collisional excitation and recombination. For highly stripped ions of moderate to high Z, relativistic effects begin to play a role in the atomic-physics calculations. A relativistic multiconfigurational distored-wave model has been used for the calculation of electron excitation cross sections and rate coefficients between the 3s2 3p6 3d10 Ni-like Gd ground state and the singly excited states with an N-shell electron.

1986-08-01

479

Power spectrum calculation for the Cornell Wiggler A SASE experiment at BNL  

Science.gov (United States)

Recently the author showed that the widely used simulation code TDA3D, even though a single frequency code, can be used to determine the power spectrum in the SASE process with excellent approximation in the exponential growth regime. In this paper, the author applies this method to the BNL Cornell Wiggler A SASE experiment as an example. When the gain is not very high, there are many modes in the radiation, which seems to make the analytical calculation very difficult. However, he shows that the increment of the radiation due to SASE over the spontaneous radiation can be expanded in terms of guided modes with rapid convergence. Thus when the spontaneous radiation is substracted from the SASE power during the calculation, there is a good agreement between the analytical theory and the numerical simulation.

1998-08-01

480

Power spectrum calculation for the Cornell Wiggler A SASE experiment at BNL  

Energy Technology Data Exchange (ETDEWEB)

Recently, we showed (Yu, Phys. Rev. E 58 (1998) 4991) that the widely used simulation code TDA3D, even though a single-frequency code, can be used to determine the power spectrum in the SASE process with excellent approximation in the exponential growth regime. In this paper, we apply this method to the BNL Cornell Wiggler A SASE experiment as an example. When the gain is not very high, there are many modes in the radiation, which seems to make the analytical calculation very difficult. However, we show that the increment of the radiation due to SASE over the spontaneous radiation can be expanded in terms of guided modes with rapid convergence. Thus when the spontaneous radiation is subtracted from the SASE power during the calculation, there is a good agreement between the analytical theory and the numerical simulation.

1999-06-01

481

Pool critical assembly benchmark solutions using MCNP and THREEDANT  

Energy Technology Data Exchange (ETDEWEB)

Analyses of pressure vessel damage resulting from neutron irradiation have primarily relied on two-dimensional transport calculations and a spatial-synthesis methodology to accommodate three-dimensional effects in the results of two two-dimensional calculations. In this paper, the authors report on calculations made on the Pool Critical Assembly (PCA) Benchmark, Configuration 12/13, using the three-dimensional, continuous energy Monte Carlo transport code, MCNP, and the three-dimensional, multigroup, diffusion accelerated discrete ordinates transport code THREEDANT. Neutron fluxes and activation rates as determined from these two calculations are compared to each other and to experimental results in the literature. The authors also draw some conclusions on the value of 3D calculations on the interpretation of experimental results.

1994-12-31

482

Polyether matrices for lithium generators; Matrices polyethers pour generateurs au lithium  

Energy Technology Data Exchange (ETDEWEB)

The use of solvating polymers of polyether type is an interesting solution for the manufacturing of high capacity lithium batteries with lithium metal anodes and which can operate at T > 50 deg. C. These operating conditions are perfectly compatible with electric-powered vehicle and stationary battery applications. In order to improve the ionic conductivity of polymer electrolytes, new aprotic and amorphous polyether lattices have been synthesized having a good conductivity but also good thermal, mechanical and electrochemical stabilities. Two type of 3-D polyether lattices obtained by reticulation of linear pre-polymers have been selected as host polymers: unsaturated poly-condensate and unsaturated co-polyethers. (J.S.) 18 refs.

1996-12-31

483

Oil Spill Simulation and Validation in the Arabian (Persian) Gulf with Special Reference to the UAE Coast  

British Library Electronic Table of Contents (United Kingdom)

The use of numerical modeling in oil spill incidents is a well established technique that has proven to provide cost-effective and reasonable estimates of oil surface drift. Good predictability of such models depends highly on the quality of the input data of the incident and on the model calibration effort. This paper presents the results of simulating oil spillage trajectory in the Arabian (Persian) Gulf. The study employed a 3-D rectilinear hydrodynamic model combined with oil spill model. Typical representative environmental conditions of the Arabian Gulf were first setup into a hydrodynamic circulation model using data from various sources. The performance of the hydrodynamic model was then tested against measurements of tidal fluctuation and sea currents at selected locations. The sp...

2007-01-01

484

Infrared study of the reaction of hydrogen with the (Co/sup 11/(CN)/sub 5/)/sup 3/- ion in deuterium oxide  

Energy Technology Data Exchange (ETDEWEB)

The effect of varying pD(11-13,7) on the reaction of hydrogen with (Co/sup 11/(CN)/sub 5/)/sup 3/- in deuterium oxide has been studied by using infrared spectroscopy to determine the ratio of (Co/sup 111/(CN)/sub 5/X)/sup 3/- (X=H,D) in the solids precipitated from the steady state under hydrogen. The results show that the uptake of hydrogen does not liberate a free proton and that the rate of (Co/sup 111/(CN)/sub 5/H)/sup 3/- -D/sub 2/,0 exchange increases with pD but becomes pD independent at pD 7 greater than 13,5.

1982-01-01

485

Improved recovery demonstration for Williston Basin carbonates. Quarterly technical progress report, October--December 1996  

Science.gov (United States)

The purpose of this project is to demonstrate targeted infill and extension drilling opportunities, better determinations of oil-in-place, methods for improved completion efficiency and the suitability of waterflooding in certain shallow-shelf carbonate reservoirs in the Williston Basin, Montana, North Dakota and South Dakota. Improved reservoir characterization utilizing 3-dimensional (3D) and multi-component seismic are being investigated for identification of structural and stratigraphic reservoir compartments. These seismic characterization tools are integrated with geological and engineering studies. Improved completion efficiency is being tested with short-lateral and horizontal drilling technologies. Improved completion efficiency, additional wells at closer spacing and better estimates of oil-in-place will result in additional oil production by primary and enhanced recovery processes.

1997-04-01

486

Improved recovery demonstration for Williston Basin carbonates  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this project is to demonstrate targeted infill and extension drilling opportunities, better determinations of oil-in- place, methods for improved completion efficiency and the suitability of waterflooding in certain shallow-shelf carbonate reservoirs in the Williston Basin, Montana, North Dakota and South Dakota. Improved reservoir characterization utilizing 3-dimensional (3D) and multi- component seismic are being investigated for identification of structural and stratigraphic reservoir compartments. These seismic characterization tools are integrated with geological and engineering studies. Improved completion efficiency is being tested with short- lateral and horizontal drilling technologies. Improved completion efficiency, additional wells at closer spacing and better estimates of oil-in-place will result in additional oil production by primary and enhanced recovery processes.

1996-09-01

487

Improved recovery demonstration for Williston Basin carbonates  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this project is to demonstrate targeted infill and extension drilling opportunities, better determination of oil-in-place, methods for improved completion efficiency and the suitability of waterflooding in certain shallow-shelf carbonate reservoirs in the Williston Basin, Montana, North Dakota and South Dakota. Improved reservoir characterization utilizing 3-dimensional (3D) is being investigated for identification of structural and stratigraphic reservoir compartments. These seismic characterization tools are integrated with geological and engineering studies. Improved completion efficiency is being tested with short lateral and horizontal drilling technologies. Improved completion efficiency, additional wells at closer spacing and better estimates of oil-in- place will result in additional oil production by primary and enhanced recovery processes.

1997-12-01

488

Improved Recovery Demonstration for Williston Basin Carbonates.  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this project is to demonstrate targeted infill and extension drilling opportunities, better determinations of oil-in- place, methods for improved completion efficiency and the suitability of waterflooding in certain shallow-shelf carbonate reservoirs in the Williston Basin, Montana, North Dakota and South Dakota. Improved reservoir characterization utilizing 3-dimensional (3-D) and multi-component seismic are being investigated for identification of structural and stratigraphic reservoir compartments. These seismic characterization tools are integrated with geological and engineering studies. Improved completion efficiency is being tested with short-lateral and horizontal drilling technologies. Improved completion efficiency, additional wells at closer spacing and better estimate of oil-in-place will result in additional oil production by primary and enhanced recovery processes.

1997-12-31

489

Improved Recovery Demonstration for Williston Basin Carbonates  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this project is to demonstrate targeted infill and extension drilling opportunities, better determinations of oil-in- place, methods for improved completion efficiency and the suitability of waterflooding in certain shallow-shelf carbonate reservoirs in the Williston Basin, Montana, North Dakota and South Dakota. Improved reservoir characterization utilizing 3-dimensional (3-D) and multi- component seismic are being investigated for identification of structural and stratigraphic reservoir compartments. These seismic characterization tools are integrated with geological and engineering studies. Improved completion efficiency is being tested with short- lateral and horizontal drilling technologies. Improved completion efficiency, additional wells at closer spacing and better estimate of oil-in-place will result in additional oil production by primary and enhanced recovery processes.

1997-03-01

490

Development of Ultra-Fast Silicon Switches for Active X-Band High Power RF Compression Systems  

Energy Technology Data Exchange (ETDEWEB)

We present the recent results of our research on the high power ultra-fast silicon RF switches. This switch is composed of a group of PIN diodes on a high purity silicon wafer. The wafer is inserted into a cylindrical waveguide under TE{sub 01} mode, performing switching by injecting carriers into the bulk silicon. Our current design uses a CMOS compatible process and the device was fabricated at SNF (Stanford Nanofabrication Facility). 300 ns switching time has been observed, while the switching speed can be improved further with 3-D device structure and faster driving circuit. Power handling capacity of the switch is at the level of 10 MW. The switch was designed for active X-band RF pulse compression systems--especially for NLC, but it is also possible to be modified for other applications and other frequencies.

2006-03-06

491

Development of Seismic Analysis Model and Time History Analysis for KALIMER-600  

Energy Technology Data Exchange (ETDEWEB)

This report describes a simple seismic analysis model of the KALIMER-600 sodium cooled fast reactor and its application to the seismic time history analysis. To develop the simple seismic analysis model, the detailed 3-D finite element analyses for main components, IHTS piping system, and reactor building were carried out to verify the dynamic characteristics of each part of simple seismic analysis models. By using the developed simple model, the seismic time history analyses for both cases of a seismic isolation and non-isolation design of KALIMER-600 were performed. From the comparison of the calculated floor response spectrum, it is verified that the seismically isolated KALIMER-600 reactor building shows a great performance of a seismic isolation and assures a seismic integrity.

2007-02-15

492

Controlled manipulation of carbon nanopillars and cantilevers by focused ion beam  

International Nuclear Information System (INIS)

We explore a novel phenomenon of focused ion beam (FIB) induced bending of carbon nanopillars or cantilever structures. The bending occurs towards the ion beam during scanning. The explanation of this bending has been sought on the basis of a model which considers temperature rise and gradients caused by the impinging ion beam. The process is controllable and reversible, which makes it highly suitable for in situ manipulation to make desired 3D shapes by the piecewise bending of the nanopillars and cantilever structures during their fabrication using electron beam or FIB chemical vapor deposition (EB-CVD or FIB-CVD). Its usefulness in the fabrication of nanosize mechanical components has been demonstrated by making a branch structure from a single cantilever.

2008-05-21

493

Cerium moment collapse in ternary silicides CePd_2_-_xMn_xSi_2 (0#<=#x#<=#2)  

International Nuclear Information System (INIS)

Cerium L_3 XANES (x-ray-absorption near-edge-structure) spectra were analyzed to separate Ce moment contributions and mixed valence (MV) in complex magnetic silicides CePd_2_-_xMn_xSi_2 (0#<=#x#<=#2). The Ce valence mixing does not vary linearly with x, but increases rapidly for x#>=#1.5. The associated moment collapse correlates with pronounced deviations of the unit-cell volume from Vegard law and the onset of structural instability. Reorientation of [001] Mn 3d antiferromagnetic order for x<2 appears to rapidly suppress the weak Ce valence mixing coexisting with antiferromagnetic order in CeMn_2Si_2.

494

Calculation of 3-D free electron laser gain: Comparison with simulation and generalization to elliptical cross section  

Energy Technology Data Exchange (ETDEWEB)

In the previous paper, we have derived a dispersion relation for the free electron laser (FEL) gain in the exponential regime taking account the diffraction and electron`s betatron oscillation. Here, we compare the growth rates obtained by solving the dispersion relation with those obtained by simulation calculation for the waterbag and the Gaussian models for the electron`s transverse phase space distribution. The agreement is found to be good except for the limiting case where the Rayleigh length is much longer than the gain length (1-D limit). We also generalize the analysis to the case where the electron beam cross section is elliptical as is usually the case in storage rings, and derive the first-order dispersion relation.

1992-08-01

495

Body-and-cad Geometric Constraint Systems  

CERN Document Server

Motivated by constraint-based CAD software, we develop the foundation for the rigidity theory of a very general model: the body-and-cad structure, composed of rigid bodies in 3D constrained by pairwise coincidence, angular and distance constraints. We identify 21 relevant geometric constraints and develop the corresponding infinitesimal rigidity theory for these structures. The classical body-and-bar rigidity model can be viewed as a body-and-cad structure that uses only one constraint from this new class. As a consequence, we identify a new, necessary, but not sufficient, counting condition for minimal rigidity of body-and-cad structures: nested sparsity. This is a slight generalization of the well-known sparsity condition of Maxwell.

2010-01-01

496

Anaerobic treatment of biodiesel by-products in a pilot scale reactor  

British Library Electronic Table of Contents (United Kingdom)

In this work, long-term operation of a pilot scale mixed anaerobic reactor processing crude glycerol and rapeseed meal is discussed. These materials are generated as by-products of biodiesel production. Mixed reactor was operated under mesophilic conditions for the period of 654 days. Total cumulative production of biogas reached 379 m3 (at atmospheric pressure and ambient temperature). Maximum volumetric loading achieved during the operation was 2.17 kg m?3 d?1 for the crude glycerol dose of 2 L. When dosing crude glycerol as a single substrate, average specific production of biogas of 0.76 m3 per L of the g-phase was achieved. The lack of nutrients in the g-phase had to be compensated by an addition of ammonium nitrogen in the form of urea into the reactor. Long term processing of crude ...

2011-01-01

497

An inexact Newton method for fully-coupled solution of the Navier-Stokes equations with heat and mass transport  

Energy Technology Data Exchange (ETDEWEB)

The solution of the governing steady transport equations for momentum, heat and mass transfer in flowing fluids can be very difficult. These difficulties arise from the nonlinear, coupled, nonsymmetric nature of the system of algebraic equations that results from spatial discretization of the PDEs. In this manuscript the authors focus on evaluating a proposed nonlinear solution method based on an inexact Newton method with backtracking. In this context they use a particular spatial discretization based on a pressure stabilized Petrov-Galerkin finite element formulation of the low Mach number Navier-Stokes equations with heat and mass transport. The discussion considers computational efficiency, robustness and some implementation issues related to the proposed nonlinear solution scheme. Computational results are presented for several challenging CFD benchmark problems as well as two large scale 3D flow simulations.

1997-02-01

498

Acoustic resonances in two-dimensional radial sonic crystal shells  

Energy Technology Data Exchange (ETDEWEB)

Radial sonic crystals (RSC) are fluidlike structures infinitely periodic along the radial direction that verify the Bloch theorem and are possible only if certain specially designed acoustic metamaterials with mass density anisotropy can be engineered (see Torrent and Sanchez-Dehesa 2009 Phys. Rev. Lett. 103 064301). A comprehensive analysis of two-dimensional (2D) RSC shells is reported here. A given shell is in fact a circular slab with a central cavity. These finite crystal structures contain Fabry-Perot-like resonances and modes strongly localized at the central cavity. Semi-analytical expressions are developed to obtain the quality factors of the different resonances, their symmetry features and their excitation properties. The results reported here are completely general and can be extended to equivalent 3D spherical shells and to their photonic counterparts.

2010-07-15

499

3D investigations of plasma erosion craters using FIB/SEM dual-beam techniques  

Energy Technology Data Exchange (ETDEWEB)

Plasma erosion craters caused by electrical discharges on the surface of materials are important features of the erosion processes resulting in the degradation of electrodes. In the present work, electrical discharges were produced on a bi-metallic Ni/Cu multilayered surface. By means of dual beam techniques, coupling a focused ion beam (FIB) and a scanning electron microscope (SEM), not only the surface but also the sub-surface structure of the craters were investigated. Using the combination of SEM, FIB and STEM-EDX, a complete three-dimensional investigation of the craters were carried out. The analysis of the microstructure modifications as a function of depth enabled to determine the field of interaction between the plasma and the material. (orig.)

2006-09-15