3-D brain CT image display for planning of craniofacial operation
International Nuclear Information System (INIS)
The authors have been developing a 3D brain CT image display system for planning of craniofacial operations. This system helps doctors plan craniofacial operations on a graphic display (GD) terminal by rendering 3D images reconstructed from a set of slices. The authors reveal how the system generates 3D shapes of organs from given CT images and how it modifies or transforms the obtained shapes according to the user's request. The system functions now available are extraction and display of the skull and the skin, measurement of the distance between two points on the skull given through the GD terminal, and generating and eliminating a polygonal region arbitrarily given on the skull as an operative region. (Auth.).
Chapter 14: Seismic imaging using 2- and 3-D migration
Energy Technology Data Exchange (ETDEWEB)
Development of a number of original 3-D migration methods and algorithms is described. The computational efficiency of these algorithms is demonstrated by implementing them on vector and parallel supercomputers. Two-dimensional post-stack and pre-stack depth migration algorithms in the frequency - space domain using implicit finite difference method were also developed and implemented on a parallel computer, and adapted for applications that range from deep crustal imaging of seismic wavefields that involve wide ranging travel times and frequencies. All implicit finite difference migration algorithms were highly prallelized . The one pass 3-D post-stack depth migration algorithm was extensively used for imaging of seismic monitoring data from Cold Lake, Alberta. Experience shows that it provides the right trade-off between accuracy and computational efficiency. ...
1999-09-01
New real-time MR image-guided surgical robotic system for minimally invasive precision surgery
Energy Technology Data Exchange (ETDEWEB)
To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and ...
2008-04-15
Repair of a Complex Congenital Cardiac Defect
... stenosis. It looks from the transesophageal and the 3-D echo that most of the problem is really ... posterior leaflet, which you can see on the 3-D echo image is a major source. The anterior ...
We develop a 3-D model to simulate the synthetic aperture radar (SAR) image formation process of an undulated vegetation canopy such as corn grown in fields with large periodic drainage reliefs. We explain how the simulated SAR image of undulated vegetation medium is obtained by the convolution of a 2-D slice of the 3-D simulated SAR system point spread function [(PSF), emulating the SAR beam modeled by a cosine modulated Gaussian], with the 2-D projection of the observed undulated vegetation canopy (modeled with scatterers randomly distributed in 3-D undulated space) followed by the extraction of each look envelope, the summation of looks, and sampling in azimuthal and range directions. Our model is useful to study the parameters involved in the formation and the analysis of SAR ...
2001-10-01
Focused ion beam assisted three-dimensional rock imaging at submicron scale
Energy Technology Data Exchange (ETDEWEB)
Computation of effective flow properties of fluids in porous media based on three dimensional (3D) pore structure information has become more successful in the last few years, due to both improvements in the input data and the network models. Computed X-ray microtomography has been successful in 3D pore imaging at micron scale, which is adequate for many sandstones. For other rocks of economic interest, such as chalk and diatomite, submicron resolution is needed in order to resolve the 3D-pore structure. To achieve submicron resolution, a new method of sample serial sectioning and imaging using Focused Ion Beam (FIB) technology has been developed and 3D pore images of the pore system for diatomite and chalk have been obtained. FIB was ...
2003-05-09
JAtlasView: a Java atlas-viewer for browsing biomedical 3D images and atlases
UK PubMed Central (United Kingdom)
BackgroundMany three-dimensional (3D) images are routinely collected in biomedical research and a number of digital atlases with associated anatomical and other information have...Full Text Available
UK PubMed Central (United Kingdom)
The 3-D spectral-domain optical coherence tomography (SD-OCT) images of the retina often do not reflect the true shape of the retina and are distorted differently along the x and y...Full Text Available
Stereotactic Radiation Therapy for Brain Tumors
... acquired, which we then volumetrically fuse with the 3D image set from the MR. And by doing ...
Energy Technology Data Exchange (ETDEWEB)
A new three-dimensional (3D) acoustic modelling method was developed using a first-order hyperbolic wave system which was solved with explicit finite dfferences. The numerical solution of the 3D wave system provides a useful method for simulating evolution of a pressure field corresponding to compressional type waves. Existing two-dimensional (2D) elastic modelling algorithms were modified and fine-tuned for computationally efficient and realistic wave propagation simulations in complex structures. An original formulation of the 3D reverse time migration method was developed which is very accurate, does not suffer from unwanted evenescent energy, can image dips beyond 90{degree}, and does not generate multiple energy. Two case studies were performed that involved steam stimulation projects in the ...
1994-12-31
Electrophysiological Study and Catheter Ablation with 3D Mapping
... see and electrophysiological study and catheter ablation with 3D mapping. During the procedure, doctors look at the ... perform a electrophysiology study with ablation, using our 3D mapping system. Keep in mind, that during the ...
An algorithm for creating synthetic telescope images of Smoothed Particle Hydrodynamics (SPH) density fields is presented, which utilises the adaptive nature of the SPH formalism in full. The imaging process uses Monte Carlo Radiative Transfer (MCRT) methods to model the scattering and absorption of photon packets in the density field, which then exit the system and are captured on a pixelated image plane, creating a 2D image (or a 3D datacube, if the photons are also binned by their wavelength). The algorithm is implemented on the density field directly: no gridding of the field is required, allowing the density field to be described to an identical level of accuracy as the simulations that generated it. Some applications of the method to star and planet formation simulations are presented to illustrate the advantages of this new technique, ...
2010-01-01
GPS and Google Earth based 3D assisted driving system for trucks in surface mines
British Library Electronic Table of Contents (United Kingdom)
In order to reduce the number of surface mining accidents related to low visibility conditions and blind spots of trucks and to provide 3D information for truck drivers and real time monitored truck information for the remote dispatcher, a 3D assisted driving system (3D-ADS) based on the GPS, mesh-wireless networks and the Google-Earth engine as the graphic interface and mine-mapping server, was developed at Virginia Tech. The research results indicate that this 3D-ADS system has the potential to increase reliability and reduce uncertainty in open pit mining operations by customizing the local 3D digital mining map, constructing 3D truck models, tracking vehicles in real time using a ...
2010-01-01
3D rotational angiography: Benefits obtained in clinical endovascular treatments
International Nuclear Information System (INIS)
The application of 3D rotational angiography marks a breakthrough in endovascular treatment of aneurysmas of the brain. 3D images are produced based on image series obtained by rotational angiography, so that the anatomic details of interest can be visualized from any requested angle. (orig./CB)
1999-01-01
3-D prestack migration in anisotropic media
Energy Technology Data Exchange (ETDEWEB)
A three-dimensional (3-D) prestack reverse-time migration algorithm for common-source P-wave data from anisotropic media is developed and illustrated by application to synthetic data. Both extrapolation of the data and computation of the excitation-time imaging condition are implemented using a second-order finite-difference solution of the 3-D anisotropic scalar-wave equation. Poorly focused, distorted images are obtained if data from anisotropic media are migrated using isotropic extrapolation; well focused, clear images are obtained using anisotropic extrapolation. A priori estimation of the 3-D anisotropic velocity distribution is required. Zones of anomalous, directionally dependent reflectivity associated with anisotropic fracture zones are detectable in both the ...
1993-01-01
Introducing DeBRa: a detailed breast model for radiological studies
Energy Technology Data Exchange (ETDEWEB)
Currently, x-ray mammography is the method of choice in breast cancer screening programmes. As the mammography technology moves from 2D imaging modalities to 3D, conventional computational phantoms do not have sufficient detail to support the studies of these advanced imaging systems. Studies of these 3D imaging systems call for a realistic and sophisticated computational model of the breast. DeBRa (Detailed Breast model for Radiological studies) is the most advanced, detailed, 3D computational model of the breast developed recently for breast imaging studies. A DeBRa phantom can be constructed to model a compressed breast, as in film/screen, digital mammography and digital breast tomosynthesis studies, or a non-compressed breast as in ...
2009-07-21
Ct3d: tracking microglia motility in 3D using a novel cosegmentation approach
UK PubMed Central (United Kingdom)
Motivation: Cell tracking is an important method to quantitatively analyze time-lapse microscopy data. While numerous methods and tools exist for tracking cells in 2D time-lapse images,...Full Text Available
2011-02-15
Catheter Ablation for Paroxysmal Atrial Fibrillation
... catheter ablation for paroxysmal atrial fibrillation procedure utilizing 3-D mapping and rotational intracardiac echocardiography. This program is ... of the MRI scan and then there's the 3-D image, which is generated from the pixels chosen ...
Accuracy of Contacts Calculated from 3D Images of Occlusal Surfaces
UK PubMed Central (United Kingdom)
ObjectiveCompare occlusal contacts calculated from 3D virtual models created from clinical records to contacts identified clinically using shimstock and transillumination.Full Text Available
2007-06-01
UK PubMed Central (United Kingdom)
In many radiotherapy clinics, geometric uncertainties in the delivery of 3D conformal radiation therapy and intensity modulated radiation therapy of the prostate are reduced by aligning the...Full Text Available
2007-07-01
A novel method to characterize the MTF in 3D for computed mammotomography
A novel phantom has been developed to measure the modulation transfer function (MTF) in 3D for x-ray computed tomography. The phantom consists of three tungsten wires, positioned nearly orthogonal to each other. Simultaneous measurements of the MTF are taken at various locations along the three orthogonal reconstructed planes. Our computed mammotomography (CmT) system uses a Varian Paxscan 2520 digital x-ray detector which can be positioned anywhere in ~2pi steradian band and can have arbitrary trajectories. With a half-cone beam geometry and with the phantom positioned near the center of rotation, projection images are acquired over 360 degrees. Various 3D orbits are evaluated including vertical axis of rotation and saddle. Reconstructions were performed using an iterative ordered-subsets transmission algorithm on rebinned projection ...
2006-03-01
Accurate positioning for head and neck cancer patients using 2D and 3D image guidance
UK PubMed Central (United Kingdom)
Our goal is to determine an optimized image-guided setup by comparing setup errors determined by two-dimensional (2D) and three-dimensional (3D) image guidance for head and neck cancer (HNC)...Full Text Available
Uranium Mass and Isotopic Analysis. A new drum tomographic gamma scanning system
Energy Technology Data Exchange (ETDEWEB)
The NIS-6 group at Los Alamos National Laboratory pioneered the development of Tomographic Gamma Scanning and continue to improve its utility in real measurement situations. Building on this experience we report the development of a state of the art TGS system suitable for industrial applications. The image reconstruction and visualization software has been integrated into the familiar Canberra NDA2000 software suite which also handles all other aspects of the data acquisition and management. In this paper we describe the salient design and performance parameters of the system. The application of gamma-ray tomography to safeguards for improved assay accuracy and knowledge confirmation is discussed. In particular we compare and contrast the relative merits of this TGS and a traditional Segmented Gamma Scanner and illustrate how the 3-D visualization of the TGS ...
2003-05-01
Energy Technology Data Exchange (ETDEWEB)
This contribution provides an overview and imparts basic knowledge on pertinent technical developments in magnetic resonance imaging (MRI) of the liver: 3D sequences, respiratory triggering, parallel imaging, and 3 Tesla (3T). 3D sequences can be used as T1-weighted (T1w) sequences for analyzing dynamics of contrast enhancement or as T2w sequences for MR cholangiography. Consistent improvements in respiratory triggering make it possible to obtain good image quality on T2w scans even in patients unable to hold their breath. Parallel imaging as a universal technique to accelerate image acquisition is particularly appropriate for MRI of the liver, and it has been shown that the reduced acquisition time is not achieved at the expense of image quality. Further progress in MRI of the ...
2004-12-01
Energy Technology Data Exchange (ETDEWEB)
Gel dosimetry is a new dosimetry method applied in radiation therapy. Gel dosimeters consist of a radiation sensitive gel, which can integrate absorbed doses from several radiation sources or beams. The dose to the gel can be evaluated by magnetic resonance imaging (MRI), a procedure that is the focus of the present thesis. A robust tool for the evaluation of the nonuniformity in MRI has been developed, the Deviation Image method. Unlike previously presented methods, the Deviation Image method includes all nonuniformity variations across a phantom surface and is insensitive to stochastic noise. Methods for the estimation of stochastic noise were analyzed in terms of sensitivity to nonuniformities. A method that averages the stochastic noise level over five regions over the phantom surface, and a method that assesses the stochastic noise level from the background, were found to be the methods of choice. Pronounced MR ...
2001-03-01
A new method of imaging particle tracks in solid state nuclear track detectors
British Library Electronic Table of Contents (United Kingdom)
Summary Solid state nuclear track detectors are used to determine the concentration of a particles in the environment. The standard method for assessing exposed detectors involves 2D image analysis. However 3D imaging has the potential to provide additional information relating to angle as well as to differentiate clustered hit sequences and possibly energy of a particles but this could be time consuming. Here we describe a new method for rapid high-resolution 3D imaging of solid state nuclear track detectors. A `LEXT' OLS3100 confocal laser scanning microscope (Olympus Corporation, Tokyo, Japan) was used in confocal mode to successfully obtain 3D image data on four CR-39 plastic detectors. Three-dimensional visualization and image analysis enabled ...
2010-01-01
Instability of 4f and 3d magnetic moments under high pressure
International Nuclear Information System (INIS)
The purpose of this paper is to demonstrate how recent experimental results of "1"5"1Eu and "5"7Fe high pressure Moessbauer studies in 4f and 3d metallic magnetic systems can contribute to a deeper understanding of the nature of local moment (4f) and itinerant (3d) magnetism in these systems. Special emphasis is given on the comparison of the experimental results with related theoretical models. (orig.).
British Library Electronic Table of Contents (United Kingdom)
Purpose Video-assisted thoracic surgery (VATS) has recently been adopted for complicated anatomical lung resections. During these thoracoscopic procedures, surgeons view the operative field on a two-dimensional (2-D) video monitor and cannot palpate the organ directly, thus frequently encountering anatomical difficulties. This study aimed to estimate the usefulness of preoperative three-dimensional (3-D) imaging of thoracic organs. Methods We compared the preoperative 64-row three-dimensional multidetector computed tomography (3DMDCT) findings of lung cancer-affected thoracic organs to the operative findings. Results In comparison to the operative findings, the branches of pulmonary arteries, veins, and bronchi were well defined in the 3D-MDCT images of 27 patients. Conclusion 3D-MDCT imag...
2009-01-01
Road Interpretation for Driver Assistance Based on an Early Cognitive Vision System
DEFF Research Database (Denmark)
In this work, we address the problem of road interpretation for driver assistance based on an early cognitive vision system. The structure of a road and the relevant traf?c are interpreted in terms of ego-motion estimation of the car, independently moving objects on the road, lane markers and large scale maps of the road. We make use of temporal and spatial disambiguation mechanisms to increase the reliability of visually extracted 2D and 3D information. This information is then used to interpret the layout of the road by using lane markers that are detected via Bayesian reasoning. We also estimate the ego-motion of the car which is used to create large scale maps of the road and also to detect independently moving objects. Sample results for the presented algorithms are shown on a stereo image sequence, that has been collected from a structured road.
2009-01-01
Three-dimensional cranio-facial computed tomography
International Nuclear Information System (INIS)
Computed tomography allows today to reconstruct three-dimensional (eD) images fram axial scans. The authors report their experience in cranio-facial pathology achived in two Departments of Radiology (University of Trieste, Italy and University of Standford, California). 3D images have been realized using two different softwares, one of which allows to reconstruct both soft tissue and bone structures. The application in maxillo-facial traumas, cranio-facial malformations and head tumours are disscussed. 3D images turned out to be very useful for the optimal visualization and for the spatial demostration of the lesion and have potential applications in cranio-facial surgery and radiotherapy.
1986-01-01
Ewald sphere correction for single-particle electron microscopy
Energy Technology Data Exchange (ETDEWEB)
Most algorithms for three-dimensional (3D) reconstruction from electron micrographs assume that images correspond to projections of the 3D structure. This approximation limits the attainable resolution of the reconstruction when the dimensions of the structure exceed the depth of field of the microscope. We have developed two methods to calculate a reconstruction that corrects for the depth of field. Either method applied to synthetic data representing a large virus yields a higher resolution reconstruction than a method lacking this correction.
2006-03-15
The role of 3D Helical CT in the reconstructive treatment of maxillofacial cancers
International Nuclear Information System (INIS)
Purpose of this work is to investigate the role of Helical CT and the usefulness of three-dimensional (3D) imaging for pre-operative planning and follow-up of reconstructive maxillofacial surgery with alloplastic material in neoplastic disease involving this region. From 1996 to 1999 eleven patients were examined with Helical CT and 3D images for planning of maxillofacial plastic and reconstructive surgery for advanced cancer of this anatomically complex region. A 3D-modulated titanium mesh (100%) or micro nets was used to rebuild the anterior surface of maxillary bone and the orbital floor. The mesh was cut to the appropriate size and shape and curved where necessary. Within the residual sinusal cavity a siliconed filling was used surmounting an acrylic prosthesis with dental arch to rebuild the palate. A rehydrated ...
2000-12-01
International Nuclear Information System (INIS)
Purpose: Three-dimensional rotational angiography (3DRA) is a new technique based on a rotational angiographic acquisition able to display arterial vessels in a 3D rendering mode. The system was mainly developed for neuroradiological evaluations but preliminary extracranial experiences have also been reported. The aim of our work was to compare the results of three-dimensional angiography of the carotid arteries done with high-flow injection of contrast medium from the aortic arch with the results of selective angiography. Materials and methods: Twenty patients underwent digital angiography of the supra-aortic vessels in order to quantify a stenosis of the carotid bifurcations previously detected at Doppler Ultrasound. Examinations were performed with the Philips Integris Allura system provided with the rotational angiography (RA) tool connected to a workstation for three-dimensional reconstruction able ...
Energy Technology Data Exchange (ETDEWEB)
The main objective of this dissertation is to build a numerical 3D geological model of a turbidite reservoir using well and seismic data. For the, the first step was to elaborate a depositional model using a high-resolution genetic stratigraphy approach. Simultaneously, the stratigraphic inversion over the seismic data resulted in an optimal acoustic impedance model. Both models, were used to build, by geostatistical methods, a 3-D geological model, which represents the spatial distribution of the reservoir facies. The studied case is the late Cretaceous Namorado turbidite system in the Campos basin, which is the reservoir of the Namorado oil field, located 80 km from the Brazilian coast, under a bathymetry between 110 and 250 m. The reservoir is a turbidite succession with 90 to 180 m thickness. It is composed by sand-supported conglomerates, matrix-supported conglomerate, massive ...
1997-01-29
Visualization and volumetric structures from MR images of the brain
Energy Technology Data Exchange (ETDEWEB)
Pinta is a system for segmentation and visualization of anatomical structures obtained from serial sections reconstructed from magnetic resonance imaging. The system approaches the segmentation problem by assigning each volumetric region to an anatomical structure. This is accomplished by satisfying constraints at the pixel level, slice level, and volumetric level. Each slice is represented by an attributed graph, where nodes correspond to regions and links correspond to the relations between regions. These regions are obtained by grouping pixels based on similarity and proximity. The slice level attributed graphs are then coerced to form a volumetric attributed graph, where volumetric consistency can be verified. The main novelty of our approach is in the use of the volumetric graph to ensure consistency from symbolic representations obtained from individual slices. In this fashion, the system allows ...
1994-03-01
Near-surface 3D reflections seismic survey; Sanjigen senso hanshaho jishin tansa
Energy Technology Data Exchange (ETDEWEB)
Faults are being actively investigated across Japan since the Great Hanshin-Awaji Earthquake. Discussed in this report is the application of the 3D near-surface reflection seismic survey in big cities. Data from trenching and drilling is used for the geological interpretation of the surroundings of a fault, and the reflection seismic survey is used to identify the position, etc., of the fault. In this article, when the results obtained from the experimental field are examined, it is found that the conventional 2D imaging reflection survey betrays the limit of its capability when the geological structure is complicated, that the 3D reflection seismic survey, on the contrary, is capable of high-precision imaging and, when augmented by drilling, etc., becomes capable of a more detailed interpretation, and that it also contributes effectively to the improvement of ...
1997-05-27
International Nuclear Information System (INIS)
Background and purpose: stereotactic radiosurgery (SRS) and also fractionated stereotactic radiotherapy (SRT) offer high local control (LC) rates (> 90%). This study aimed to evaluate three-dimensional (3-D) tumor volume (TV) shrinkage and to assess quality of life (QoL) after SRS/SRT. Patients and methods: from 1999 to 2005, 35/74 patients were treated with SRS, and 39/74 with SRT. Median age was 60 years. Treatment was delivered by a linear accelerator. Median single dose was 13 Gy (SRS) or 54 Gy (SRT). Patients were followed up ? 12 months after SRS/SRT. LC and toxicity were evaluated by clinical examinations and magnetic resonance imaging. 3-D TV shrinkage was evaluated with the planning system. QoL was assessed using the questionnaire Short Form-36. Results: Median follow-up was 50/36 months (SRS/SRT). Actuarial 5-year freedom from progression/overall ...
2009-09-01
International Nuclear Information System (INIS)
Three dimensional data of brain from the formalin-fixed fetuses were collected without isolation, by the 4.7 tesla super high magnetic field MRI and the developmental process of the cerebral parenchyma was studied by 3D images. Subjects were 13 fetal brain and MRI was performed using 3D-steady-state free precession sequence. The isolated brain is very soft and fragile and is deformed by its weight at the imaging. However 3D-MRI can be obtained without isolation, and the deformation is remarkably small. The subependymal germinal matrix layer did not be observed in 7 weeks-old fetus, appeared at 9 weeks-old and increased gradually. Then it rapidly reduced from 28 weeks-old. The volume calculated, from 3D-MRI, increased rapidly from 9 weeks-old to 23 weeks-old, and reached the ...
1999-10-01
Quantitative analysis of X-Ray Microtomography images of metal powders in the course of sintering
Energy Technology Data Exchange (ETDEWEB)
In situ X-Ray microtomography offers new opportunities for analysing sintering mechanisms since it allows 3D observation of the microstructural evolution of the powder all along a sintering cycle. With synchrotron radiation at ESRF, a 3D image with a resolution of 2 {mu}m can be obtained in about one minute. In addition to the visual examination of the images, relevant microstructural parameters can be measured through quantitative image analysis using recently developed tools. In this paper the results obtained with two materials, loose copper powder and compacted steel powder, are resumed. For copper powder, the dispersion of local parameters such as particle co-ordination number and porosity is investigated. Concerning steel compacts, data about pore morphology evolution and on local strains provides clues for understanding the ...
2005-07-01
Resolution enhancement by subtraction of confocal signals taken at different pinhole sizes.
Subtractive imaging in confocal fluorescence light microscopy is based on the subtraction of a suitably weighted widefield image from a confocal image. An approximation to a widefield image can be obtained by detection with an opened confocal pinhole. The subtraction of images enhances the resolution in-plane as well as along the optic axis. Due to the linearity of the approach, the effect of subtractive imaging in Fourier-space corresponds to a reduction of low spatial frequency contributions leading to a relative enhancement of the high frequencies. Along the direction of the optic axis this also results in an improved sectioning. Image processing can achieve a similar effect. However, a 3D volume dataset must be acquired and processed, yielding a result essentially identical to subtractive ...
2003-01-01
Applications with a new low-temperature UHV STM at 5 K
International Nuclear Information System (INIS)
A new dedicated UHV STM for investigations at T#<=#5 K is presented. To achieve such low temperatures and to ensure a high thermal stability, the low-temperature (LT) STM described here has a concentric system of bath cryostats. There are openings for tip and sample exchange at low T, and windows with an infrared radiation shield for optical access, which can both be closed by a door mechanism for LT-STM measurements. Efficient vibration isolation is realized by using spring suspension with eddy current damping. With the 3-d coarse positioning unit any region of interest within 5 mm by 5 mm on the sample is accessible even at 5 K. For short turn-around cycles the sample and tip can both be exchanged at low temperatures. Atomically resolved images of Au(111) at 5 K in UHV demonstrate the excellent performance of this LT STM. As a typical application example the appearance of a charge-density wave on ...
1998-03-01
Transplantation of engineered bone tissue using a rotary three-dimensional culture system.
Bone is a complex, highly structured, mechanically active, three-dimensional (3-D) tissue composed of cellular and matrix elements. We previously published a report on in situ collagen gelation using a rotary 3-D culture system (CG-RC system) for the construction of large tissue specimens. The objective of the current study was to evaluate the feasibility of bone tissue engineering using our CG-RC system. Osteoblasts from the calvaria of newborn Wistar rats were cultured in the CG-RC system for up to 3 wk. The engineered 3-D tissues were implanted into the backs of nude mice and calvarial round bone defects in Wistar rats. Cell metabolic activity, mineralization, and bone-related proteins were measured in vitro in the engineered 3-D ...
2007-03-11
Development of a motion analysis system using acceleration sensors for tennis and its evaluations
British Library Electronic Table of Contents (United Kingdom)
The term biological motion is often used by researchers studying the patterns of movement generated by living forms and in sports. We studied a pattern recognition system of motion in sport using biological motion data. Biological motion data are acquired using a 3D motion capture system. However, 3D motion capture systems are very expensive. In this article, a biological motion capture system was built using acceleration sensors. Our proposed system uses the technique of Gaussian fitting and regression analysis. We tested our proposed system in pattern recognition of outdoor tennis and its evaluations.
2011-01-01
Initiation of conformal radiotherapy with a multileaf-collimator - An approach to clinical routine
International Nuclear Information System (INIS)
The implementation of a three-dimensional conformal radiotherapy facility in the radiotherapy department of the Heinrich Heine University is described. Complex radiotherapy techniques with commercially available networked systems are introduced to improve clinical work. Over 18 month we have gained clinical experience with a PHILIPS Multileaf Collimator (MLC) mounted on a SL 25 linear accelerator. For a limited period the MLC was used as a conventional blocking device. The standard MLC-shapes are controlled with a stand-alone computer system. In addition, a three-dimensional treatment planning system (3-D-TPS / TMS-Radix, Helax AB) based on convolution/superposition algorithms was recently installed. Treatment optimization is achieved using static field arrangements with complete volumetric computerized tomographic patient data for 3-D-TPS. ...
1995-10-01
Energy Technology Data Exchange (ETDEWEB)
The aim of this study is three folds: to compare the eight-channel phased-array and standard circularly polarized (CP) head coils in visualiazation of the intracranial vessels, to compare the three-dimentional (3D) time-of-flight (TOF) MR angiography (MRA) techniques, and to define the effects of parallel imaging in 3D TOF MRA. Fifteen healthy volunteers underwent 3D TOF MRA of the intracranial vessels using eight-channel phased-array and CP standard head coils. The following MRA techniques were obtained on each volunteer: (1) conventional 3D TOF MRA with magnetization transfer; (2) 3D TOF MRA with water excitation for background suppression; and (3) low-dose (0.5 ml) gadolinium-enhanced 3D TOF MRA with water ...
2004-11-01
The safety issues of medical robotics
International Nuclear Information System (INIS)
In this paper, we put forward a systematic method to analyze, control and evaluate the safety issues of medical robotics. We created a safety model that consists of three axes to analyze safety factors. Software and hardware are the two material axes. The third axis is the policy that controls all phases of design, production, testing and application of the robot system. The policy was defined as hazard identification and safety insurance control (HISIC) that includes seven principles: definitions and requirements, hazard identification, safety insurance control, safety critical limits, monitoring and control, verification and validation, system log and documentation. HISIC was implemented in the development of a robot for urological applications that was known as URObot. The URObot is a universal robot with different modules adaptable for 3D ultrasound image-guided interstitial ...
2001-08-01
Real-time 3-D SAFT-UT system evaluation and validation
International Nuclear Information System (INIS)
SAFT-UT technology is shown to provide significant enhancements to the inspection of materials used in US nuclear power plants. This report provides guidelines for the implementation of SAFT-UT technology and shows the results from its application. An overview of the development of SAFT-UT is provided so that the reader may become familiar with the technology. Then the basic fundamentals are presented with an extensive list of references. A comprehensive operating procedure, which is used in conjunction with the SAFT-UT field system developed by Pacific Northwest Laboratory (PNL), provides the recipe for both SAFT data acquisition and analysis. The specification for the hardware implementation is provided for the SAFT-UT system along with a description of the subsequent developments and improvements. One development of technical interest is the SAFT real time processor. Performance of the real-time processor is impressive and comparison is made ...
1993-05-17
A computer-assisted method for 3D subtraction angiography based on spiral CT
International Nuclear Information System (INIS)
The objective of this study was to develop a method for 3D subtraction CT angiography and to optimize the visualization after semiautomatic segmentation. Ten patients with aneurysms of the abdominal aorta were examined using spiral CT. To reconstruct the vessels, as well as adjacent organs such as the liver and kidneys, one image data volume was acquired before and after injection of the contrast agent. The CT scans were obtained with a Siemens Somatom Plus 4. To improve the results of automatic segmentation, as well as visualization by maximum intensity projection (i.e. removal of bony structures), subtraction of both image volumes is necessary. However, small translation shifts disturb the subtraction process and produce artificial contours. To calculate the disparities along the three coordinate axes of two corresponding image volumes, a cepstrum filter is applied to a pair of ...
Atlas of nuclear medicine imaging
Energy Technology Data Exchange (ETDEWEB)
An exhaustive compendium of normal and abnormal imaging is presented. The following systems and procedures are illustrated by over 2800 captioned illustrations: liver, spleen, and hepatobiliary imaging; perfusion and ventilation lung imaging; thyroid imaging; salivary gland imaging; bone imaging; brain imaging; radionuclide cisternography; blood flow studies; gallium imaging; nuclear cardiology; and renal imaging. Not included in the atlas are adrenal imaging procedures and emission computed tomography. (ERB)
1981-01-01
Evaluation of tilted cone-beam CT orbits in the development of a dedicated hybrid mammotomograph
UK PubMed Central (United Kingdom)
A compact dedicated 3D breast SPECT-CT (mammotomography) system is currently under development. In its initial prototype, the cone-beam CT sub-system is restricted to a fixed-tilt circular rotation...Full Text Available
2009-06-21
New MR techniques in diagnostic imaging of joints; Neue MRT-Techniken in der Gelenkdiagnostik
Energy Technology Data Exchange (ETDEWEB)
Already, MR Imaging is superior in diagnostic imaging of joints in many cases; however, there have been recent developments, which are the subjects of this paper. With gradient-echo sequences acquired in 3D technique, it is possible to produce high-resolution images of joints in acceptable scantime, because gradient-echo sequences are less time-consuming than convential SE sequences. With the acquisition of two echoes, phase difference between water and fat protons have to be considered. 3D Imaging is capable of displaying complex pathology in a superior way, which should be useful in preoperative planning. Tissue contrast is altered by fat saturation or magnetization transfer in order to achieve better conspicuity of lesions. Although diagnostic value of some of these options is not yet clear and further clinical ...
1993-12-31
TIME EVOLUTION OF CORONAL MAGNETIC HELICITY IN THE FLARING ACTIVE REGION NOAA 10930
International Nuclear Information System (INIS)
To study the three-dimensional (3D) magnetic field topology and its long-term evolution associated with the X3.4 flare of 2006 December 13, we investigate the coronal relative magnetic helicity in the flaring active region (AR) NOAA 10930 during the time period of December 8-14. The coronal helicity is calculated based on the 3D nonlinear force-free magnetic fields reconstructed by the weighted optimization method of Wiegelmann, and is compared with the amount of helicity injected through the photospheric surface of the AR. The helicity injection is determined from the magnetic helicity flux density proposed by Pariat et al. using Solar and Heliospheric Observatory/Michelson Doppler Imager magnetograms. The major findings of this study are the following. (1) The time profile of the coronal helicity shows a good correlation with that of the helicity accumulation by injection through ...
2010-09-10
Natural Gaits of the Non-Pathological Flat Foot and High-Arched Foot
UK PubMed Central (United Kingdom)
There has been a controversy as to whether or not the non-pathological flat foot and high-arched foot have an effect on human walking activities. The 3D foot scanning system was employed to obtain static...Full Text Available
The purpose of this study was to use high-resolution magnetic resonance (MR) imaging combined with image analysis to investigate the three-dimensional (3D) trabecular structure, anisotropy, and connectivity of human vertebral, femoral, and calcaneal specimens. The goal was to determine whether: (a) MR-derived measures depict known skeletal-site-specific differences in architecture and orientation of trabeculae; (b) 3D architectural parameters combined with bone mineral density (BMD) improve the prediction of the elastic modulus using a fabric tensor formulation; (c) MR-derived 3D architectural parameters combined with BMD improve the prediction of strength using a multiple regression model, and whether these results corresponded to the results obtained using higher resolution depictions of trabecular architecture. A ...
1998-05-01
A 3-D hydrodynamic dispersion model for modeling tracer transport in Geothermal Reservoirs
International Nuclear Information System (INIS)
A 3-D hydrodynamic dispersion model for tracer transport is developed and implemented into the TOUGH2 EOS3 (T2R3D) module. The model formulation incorporates a full dispersion tensor, based on a 3-D velocity field with a 3-D, irregular grid in a heterogeneous geological system. Two different weighting schemes are proposed for spatial average of 3-D velocity fields and concentration gradients to evaluate the mass flux by dispersion and diffusion of a tracer or a radionuclide. This new module of the TOUGH2 code is designed to simulate processes of tracer/radionuclide transport using an irregular, 3-D integral finite difference grid in non-isothermal, three-dimensional, multiphase, porous/fractured subsurface ...
Characterisation of thin films on rough steel substrates by FTIR microscopy and imaging
International Nuclear Information System (INIS)
Complete text of publication follows. According to the new European regulations (Restrictions of Hazardous Substance Directive), there is an emerging demand for environmental friendly metal treatments instead on formerly used chromate conversion coating technique. The aim of the present investigations was to characterise and compare silicon containing protective thin layers on roughened galvanized steel surfaces (with average roughness of 0.7 microns), using FTIR microscopy and imaging techniques. The silicon containing coatings were produced either by Chemical Vapour Deposition (CVD) or by wet chemical treatment using liquid silane. FTIR techniques offer new possibilities in the characterisations and chemical mapping of differently coated thin films, besides SEM+EDS, AFM, nanoindentation, XPS measurements (P. Nemeth et al., Materials Science Forum, 589 (2008) 433-438). All measurements were carried out by a Varian FTS-7000 spectrometer with a 'Stingray' microscope ...
3D modelling as a support to thermal-hydraulic safety analyses with standard codes
Energy Technology Data Exchange (ETDEWEB)
A three-dimensional (3D) thermal-hydraulic model and a numerical procedure for the simulation and analysis of a steady-state, as well as transient operation of nuclear power plant components are presented. A two-fluid approach is applied to modelling of two-phase flow. Thermal-hydraulics of a horizontal steam generator in the WWER 1000 nuclear power plant has been simulated at the full load, steady-state operation. A comparison of the numerical results with data measured at the NPP Novovoronjezh shows good agreement. 3D numerical results can be used in plant design or retrofitting, in nuclear power plant operation and safety analysis and as improvement of existing one-dimensional thermal-hydraulics models of the horizontal steam generator which are assessed by system codes used for the nuclear power plant safety analyses. (author)
1999-07-01
3D modelling as a support to thermal-hydraulic safety analyses with standard codes
International Nuclear Information System (INIS)
A three-dimensional (3D) thermal-hydraulic model and a numerical procedure for the simulation and analysis of a steady-state, as well as transient operation of nuclear power plant components are presented. A two-fluid approach is applied to modelling of two-phase flow. Thermal-hydraulics of a horizontal steam generator in the WWER 1000 nuclear power plant has been simulated at the full load, steady-state operation. A comparison of the numerical results with data measured at the NPP Novovoronjezh shows good agreement. 3D numerical results can be used in plant design or retrofitting, in nuclear power plant operation and safety analysis and as improvement of existing one-dimensional thermal-hydraulics models of the horizontal steam generator which are assessed by system codes used for the nuclear power plant safety analyses. (author)
1999-04-19
Energy Technology Data Exchange (ETDEWEB)
The treatment of bony, osteochondral, and ligamentous injuries of the tibio-talar requires precise preoperative planning by radiological investigation. This is essential to a correct understanding of the underlying pathology and will allow a proper classification of the injury, which is the basis of treatment. Conventional radiography using anteroposterior and lateral X-rays with comparative views of the noninjured side and, if necessary, rotated spot views and tomography are of high value especially in osteochondral fractures of the talus. Intraoperative control images in both planes after osteosynthesis are mandatory. For evaluation of the postoperative course and severity of arthrosis formation, the classification system of Bargon has proved its worth. In addition, tomography of the tibio-talar joint in two planes is useful especially in tibial pilon fractures, some malleolar fractures, and peripheral talar fractures. In talar fracture ...
1991-12-01
Energy Technology Data Exchange (ETDEWEB)
This document is a user`s manual for the Rn3D finite element code. Rn3D was developed to simulate gas flow and radon transport in variably saturated, nonisothermal porous media. The Rn3D model is applicable to a wide range of problems involving radon transport in soil because it can simulate either steady-state or transient flow and transport in one-, two- or three-dimensions (including radially symmetric two-dimensional problems). The porous materials may be heterogeneous and anisotropic. This manual describes all pertinent mathematics related to the governing, boundary, and constitutive equations of the model, as well as the development of the finite element equations used in the code. Instructions are given for constructing Rn3D input files and executing the code, as well as a description of all output files generated ...
1994-01-01
We propose the Particle Swarm Optimization (PSO) as an alternative method for locating periodic orbits in a three--dimensional (3D) model of barred galaxies. We develop an appropriate scheme that transforms the problem of finding periodic orbits into the problem of detecting global minimizers of a function, which is defined on the Poincar\\'{e} Surface of Section (PSS) of the Hamiltonian system. By combining the PSO method with deflection techniques, we succeeded in tracing systematically several periodic orbits of the system. The method succeeded in tracing the initial conditions of periodic orbits in cases where Newton iterative techniques had difficulties. In particular, we found families of 2D and 3D periodic orbits associated with the inner 8:1 to 12:1 resonances, between the radial 4:1 and corotation resonances of our ...
2005-01-01
Three-dimensional power system stabilizer
Energy Technology Data Exchange (ETDEWEB)
Power system stabilizers (PSSs) are used to enhance damping of power system oscillations through excitation control of synchronous generator. The objective of the PSS is to generate a stabilizing signal, which produces a damping torque component on the generator shaft. Conventional PSSs are designed with the phase compensation technique in the frequency domain and include the lead-lag blocks whose parameters are determined according to a linearized power system model. The performance of conventional PSSs (CPSSs) depends upon the generator operating point and the system parameters, but a reasonable level of robustness can be achieved depending on the tuning method. This paper presents a new three-dimensional PSS (3D PSS), which uses rotor speed deviation, rotor acceleration and load angle deviation as input signals. The ...
2010-07-15
International Nuclear Information System (INIS)
Energy-filtered X-ray photoemission electron microscopy (EXPEEM) is a microscopy technique which has the potential to provide surface chemical mapping during surface chemical processes on the nanometer scale. We studied the possibilities of EXPEEM using a Wien filter type energy analyzer in the high energy X-ray region above 1000 eV. We have successfully observed the EXPEEM images of Au islands on a Ta sheet using Au 3d_5_/_2 and Ta 3d_5_/_2 photoelectron peaks which were excited by 2380 eV X-rays emitted from an undulator (BL2A) at Photon Factory. Our recent efforts to improve the sensitivity of the Wien filter energy analyzer will also be discussed.
2004-10-15
Automated three-dimensional X-ray analysis using a dual-beam FIB
International Nuclear Information System (INIS)
We present a fully automated method for three-dimensional (3D) elemental analysis demonstrated using a ceramic sample of chemistry (Ca)MgTiO_x. The specimen is serially sectioned by a focused ion beam (FIB) microscope, and energy-dispersive X-ray spectrometry (EDXS) is used for elemental analysis of each cross-section created. A 3D elemental model is reconstructed from the stack of two-dimensional (2D) data. This work concentrates on issues arising from process automation, the large sample volume of approximately 17x17x10 #mu#m"3, and the insulating nature of the specimen. A new routine for post-acquisition data correction of different drift effects is demonstrated. Furthermore, it is shown that EDXS data may be erroneous for specimens containing voids, and that back-scattered electron images have to be used to correct for these errors.
2007-08-01
Applicator reconstruction and applicator shifts in 3D MR-based PDR brachytherapy of cervical cancer
British Library Electronic Table of Contents (United Kingdom)
Purpose To evaluate the methods of applicator reconstruction in 3D MR-based planning for brachytherapy of cervical cancer, and to investigate applicator shifts and changes in DVH parameters during PDR treatment. Methods For each application MR scans with applicator in situ were made: three T2-weighted (4.5mm slices) Turbo Spin Echo (TSE) scans and a balanced Steady State Free Precession scan (1.5mm). Three observers tested two applicator reconstruction methods: (A) directly on the bSSFP scan and (B) on a resampled combination of the three T2-weighted scans. For 10 patients MR imaging was repeated on the second day of each PDR fraction to determine applicator shifts and changes in DVH parameters. Results For both applicator reconstruction methods the interobserver variation for the DVH para...
2009-01-01
An integrated Tomographic Gamma Scanning system for non-destructive assay of radioactive waste
Energy Technology Data Exchange (ETDEWEB)
The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm{sup -3} or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant ...
2007-08-21
An integrated Tomographic Gamma Scanning system for non-destructive assay of radioactive waste
International Nuclear Information System (INIS)
The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm"-"3 or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant applications. ...
2007-08-21
Energy Technology Data Exchange (ETDEWEB)
Purpose: The aim of this study was to evaluate the accuracy of MRI in the measurement of cartilage thickness of the ankle joint in comparison to pathologic and histologic specimens. Patients and methods: The ankle joints of four fresh cadaver feet were imaged on a 1.5 T MR-unit in the coronal plane. Standard T{sub 1}-weighted spin echo (SE) and a T{sub 1}-weighted 3D-GE (FLASH-3D) sequence with fat saturation were applied. Following MR imaging, the talus was explanted and cut parallel to the MR images for macroscopic evaluation and histologic specimens were prepared. MRI measurements of the cartilage thickness of the talus were carried out in two ways: Without and with consideration of a transition zone of intermediate signal intensity between hyperintense cartilage and hypointense cortical bone. The data were compared with the anatomic ...
1997-04-01
Energy Technology Data Exchange (ETDEWEB)
Purpose: `Exoscopic` and endoscopic identification of colorectal pathologies via MRI. Methods: 5 patients (36-88 years), two normal and three with different colorectal pathologies (diverticular disease, polyps and carcinoma of the colon), were examined by MRI after colonoscopy. Subsequent to filling of the colon with a gadolinium-water mixture under MRI-monitoring, 3D-data sets of the colon were acquired in prone and supine positions over a 28 sec breathold interval. Subsequently multiplanar T{sub 1}-weighted 2D-sequences were acquired before and following i.v. administration of Gd-DTPA (0.1 mmol/kg BW). All imaging was performed in the coronal orientation. The 3D-data were interactively analysed based on various displays: Maximum intensity projection (MIP), surface shadowed display (SSD), multiplanar reconstruction (MPR), virtual colonoscopy (VC). Results: All of the colorectal ...
1997-09-01
Prediction of parallel NIKE3D performance on the KSR1 system
Energy Technology Data Exchange (ETDEWEB)
Finite element method is one of the bases for numerical solutions to engineering problems. Complex engineering problems using finite element analysis typically imply excessively large computational time. Parallel supercomputers have the potential for significantly increasing calculation speeds in order to meet these computational requirements. This paper predicts parallel NIKE3D performance on the Kendall Square Research (KSR1) system. The first part of the prediction is based on the implementation of parallel Cholesky (U{sup T}DU) matrix decomposition algorithm through actual computations on the KSRI multiprocessor system, with 64 processors, at Oak Ridge National Laboratory. The other predictions are based on actual computations for parallel element matrix generation, parallel global stiffness matrix assembly, and parallel forward/backward substitution on the BBN TC2000 multiprocessor ...
1995-05-01
Impact of computers in radiography: the advent of digital radiography, part-2
International Nuclear Information System (INIS)
Computed radiography (CR) systems use a photostimulable phosphor plate enclosed in a cassette. In CR, image acquisition is a two-stage process wherein image capture and image read out are done separately. Direct digital radiography (DR) systems, on the other hand, use detectors that have a combined image capture and image read out capability. DR systems are also called as DDR or ddR systems by some vendors. This article focuses on DR systems
2008-08-01
Energy Technology Data Exchange (ETDEWEB)
DVR project concerns the creation of a virtual reality OpenGL system for desktop applications in archaeology. The main goal is the creation of a 3D information system using the real time interaction of OpenGL environments. The first case study implemented is the Vettii House, one of the most important and outstanding monuments in Pompei. The virtual reconstruction of these architectural models is based on very detailed photogrammetric surveys and it is connected with information layers and archaeometric data-bases regarding the state of conservation of walls, structures and any type of materials of the monument. A full 3D interface characterizes the system, comprising a high resolution texturing with detailed volumetric and geometric data. Finally, for the future, the project plans to fit the system for scientific and ...
2001-07-01
Multi-modality imaging of uveal melanomas using combined PET/CT, high-resolution PET and MR imaging
Energy Technology Data Exchange (ETDEWEB)
We investigated the efficacy of combined FDG-PET/CT imaging for the diagnosis of small-size uveal melanomas and the feasibility of combining separate, high-resolution (HR) FDG-PET with MRI for its improved localization and detection. Patients, methods: 3 patients with small-size uveal melanomas (0.2-1.5 ml) were imaged on a combined whole-body PET/CT, a HR brain-PET, and a 1.5 T MRI. Static, contrast-enhanced FDG-PET/CT imaging was performed of head and torso with CT contrast enhancement. HR PET imaging was performed in dynamic mode 0-180 min post-injection of FDG. MRI imaging was performed using a high-resolution small-loop-coil placed over the eye in question with T2-3D-TSE and T1-3D-SE with 18 ml Gd-contrast. Patients had their eyes shaded during the scans. Lesion visibility on high-resolution ...
2008-07-01
International Nuclear Information System (INIS)
The experimental has been performed with a view to studying complete and incomplete fusion in "1"4N + "1"6"3D_y system below 7 MeV/nucleon. The excitation functions for several reactions have been measured using the activation technique and compared with the theoretical predictions based on statistical models. The codes ALICE-91 and CASCADE used earlier for the analysis of excitation functions in case of "1"2C + "1"6"5H_0 system have been used here also with the same set of input parameters. It has been observed that the theoretical calculations do not match with the experimental excitation functions well but the overall shape of the excitation function is reproduced satisfactorily. The composite nucleus ("1"7"7T_a) formed in this ("1"4N + "1"6"3D_y) case is the same as the one formed in "1"2C + "1"6"5H_0 system studied earlier. Measured ...
2002-10-01
The vertical profiles of disc galaxies are built by the material trapped around stable periodic orbits, which form their "skeletons". According to this, the knowledge of the stability of the main families of periodic orbits in appropriate 3D models, can predict possible morphologies for edge-on disc galaxies. In a pilot survey we compare the orbital structures which lead to the appearance of "peanuts" and "X"-like features with the edge-on profiles of three disc galaxies (IC 2531, NGC 4013 and UGC 2048). The subtraction from the images of a model representing the axisymmetric component of the galaxies reveals the contribution of the non-axisymmetric terms. We find a direct correspondence between the orbital profiles of 3D bars in models and the observed main morphological features of the residuals. We also apply a simple unsharp masking technique in order to study the sharpest ...
2006-01-01
Energy Technology Data Exchange (ETDEWEB)
Purpose: To assess the new method of 3-dimensional echocardiography in comparison to the 'gold standard' MRI as to its ability to calculate left ventricular volumes in patients with congenital heart disease. Materials and methods: Eighteen patients between the ages of 3.9 to 37.3 years (mean: 12.8{+-}9.7) with a geometrically abnormal left ventricle were examined using a 1.5 T scanner with a fast gradient-echo sequence (TR=14 ms, TE=2.6-2.9 ms, FOV=300-400 mm, flip angle=20 , matrix=128:256, slice thickness=5 mm, retrospective gating) in multislice-multiphase technique. Transthoracic 3D-echocardiography was performed with a 3.5 MHz transducer and a Tomtec {sup trademark} (Munich, Germany) system for 3D reconstruction. Results: Volume calculation was possible in all patients with 3D-echocardiography, but the muscle mass ...
2003-07-01
Conformal radiation therapy: technical requirements and clinical applications
International Nuclear Information System (INIS)
Conformal radiation therapy represents a considerable and attractive challenge in oncology. Its aim is mainly to improve local control by increasing the dose with an acceptable rate of complications. This work overviews the world literature on this subject. The technical and theoretical requirements are highlighted. These requirements include a precise definition of the target volume by digital imaging (essentially CT scan), but also clear view of the target volume and the organs at risk, a specific collimation of the beam, 3-D dose calculations, optimization procedures, and a rigid immobilization of the patient with verification of his position. Moreover, the clinical applications of conformal radiation therapy are reviewed and discussed. (authors). 80 refs., 1 tab.
1995-01-01
Real time neutron radiography using a Lixi neutron imaging device
Energy Technology Data Exchange (ETDEWEB)
A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Illinois. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be ...
1986-01-15
Real time neutron radiography using a Lixi neutron imaging device
International Nuclear Information System (INIS)
A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Ill. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further ...
1986-01-01
An Effective Method of Image Retrieval using Image Mining Techniques
The present research scholars are having keen interest in doing their research activities in the area of Data mining all over the world. Especially, [13]Mining Image data is the one of the essential features in this present scenario since image data plays vital role in every aspect of the system such as business for marketing, hospital for surgery, engineering for construction, Web for publication and so on. The other area in the Image mining system is the Content-Based Image Retrieval (CBIR) which performs retrieval based on the similarity defined in terms of extracted features with more objectiveness. The drawback in CBIR is the features of the query image alone are considered. Hence, a new technique called Image retrieval based on optimum clusters is proposed for improving user interaction with ...
2010-01-01
Digital processing to improve image quality in real-time neutron radiography
Energy Technology Data Exchange (ETDEWEB)
Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a ...
1985-01-01
Digital processing to improve image quality in real-time neutron radiography
International Nuclear Information System (INIS)
Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a ...
1985-01-01
3D Atlas vertical plate oil transmission line field calculations. Final report
Energy Technology Data Exchange (ETDEWEB)
Because of questions regarding current density and inductance estimates of the Atlas oil transmission line in the region where the vertical plates connect to the disk line, calculations using the 3D FE program Flux3d were initiated. Flux3d inductance values are nearly that estimated by D. Scudder. Calculations for three base designs of E. Ballard and D. Pierce were completed where several variations for each base design were used to determine the important parameters affecting inductance and to check inductance consistency. Flux3d showed for the first base design a very high current density of 36MA/m at the connection between the vertical and horizontal ground plates resulting in a magnetic pressure of 120 kpsi. The second base design modified this connection to reduce the current density to 20MA/m and 36 kpsi and for ...
1997-09-18
International Nuclear Information System (INIS)
The aim of this work was to develop several strategies and software-packages for the evaluation of in-vivo-data of the human brain, which were acquired with high-resolution 1H-MRSI at 1.5 and 3 T. Several studies involving phantoms, volunteers and patients were performed. Quality assurance studies were conducted in order to evaluate the reproducibility of the applied MR-techniques at both field strengths. A qualitative comparison-study between MRSI-data from a 1.5 T clinical MR-scanner and a 3 T research MR-scanner showed the advantages of the more advanced MRSI sequences and higher field strength (3 T). A study involving patients with primary brain tumours (gliomas) was performed in cooperation with the Department of Neurosurgery (University of Erlangen-Nuremberg). The methods developed in the course of this study, such as the integration of MRS-data into a stereotactic-system, the segmentation of metabolic maps and the correlation with histopathological findings ...
International Nuclear Information System (INIS)
In order to predict or to evaluate the structural reliability of a variety of nuclear components under actual changing operating conditions, it is necessary to take the detailed geometrical features of components into consideration on one hand, and thermo-mechanical loading conditions with space and time variations during the lifetime, on the other hand. This consideration leads the authors to develop a super large-scale structural analysis program based on a parallel computational FEM with a variable scale of PC cluster architecture, whose prototype system is presented in a companion paper in this Symposium. Development of the PC cluster technology is one of the most important subjects in large-scale structural simulation, reducing computer costs and thus making simulation more acceptable to the engineering community. This paper presents the developmental status of the parallel FEM solver, demonstrating computational capabilities with three dimensional effects ...
2000-09-01
Multi-domain, higher order level set scheme for 3D image segmentation on the GPU
DEFF Research Database (Denmark)
Level set method based segmentation provides an efficient tool for topological and geometrical shape handling. Conventional level set surfaces are only $C^0$ continuous since the level set evolution involves linear interpolation to compute derivatives. Bajaj et al. present a higher order method to evaluate level set surfaces that are $C^2$ continuous, but are slow due to high computational burden. In this paper, we provide a higher order GPU based solver for fast and efficient segmentation of large volumetric images. We also extend the higher order method to multi-domain segmentation. Our streaming solver is efficient in memory usage.
2010-01-01
International Nuclear Information System (INIS)
The objective of this project is to develop multi-dimensional computational models in order to improve the operation of uranium electrorefiners currently used in pyroprocessing technology. These 2-D (US) and 3-D (ROK) mathematical models are based on the fundamental physical and chemical properties of the electrorefiner processes. The validated models by compiled and evaluated experimental data could provide better information for developing advanced electrorefiners for uranium recovery. The research results in this period are as follows: - Successfully assessed a common computational platform for the modeling work and identify spatial characterization requirements. - Successfully developed a 3-D electro-fluid dynamic electrorefiner model. - Successfully validated and benchmarked the two multi-dimensional models with compiled experimental data sets
2008-08-01
Particle-Sizing System for Scanning Electron Microscope ...
... THESIS PARTICLE-SIZING SYSTEM FOR SCANNING ELECTRON MICROSCOPE IMAGES OF SOLID-PROPELLANT COMBUSTION EXHAUST ...
1991-03-01
A Computer Vision System forAnalyzing Images of Rough Hardwood Lumber
... In this paper research aimed at creating a computer vision system to power such an optimal edging and ... ...
Multislice helical CT in the diagnosis of hilar cholangiocarcinoma
International Nuclear Information System (INIS)
Objective: To investigate the value ofMSCT in observing the direct findings of hilar cholangiocarcinoma1Methods Multislice helical CT studies were performed on the upper abdomen in 19 consecutive patientswith painless jaundice1 Precontrast and dynamic contrast enhanced (25 s phase and 60 s phase) scanswere conducted, and 3D imageswere reconstructed using enhanced raw data in 15 cases1 The direct CT findings of hilar cholangiocarcinoma were studied by three radiologists respectively in a 32scale strategy1 The morphological features and extension of bile duct involvement by hilar cholangiocarcinoma were analyzed1 All the 19 caseswere pathologically p roved as hilar cholangiocarcinoma by surgery (15 cases) and ERCP ( 4 cases) 1 Results The direct findings and extension of hilar cholangiocarcinoma could be demonstrated in 14 out of 15 3D reconstruction images, 8 out of 19 in 25 s phase, ...
2005-11-01
Phantom and animal imaging studies using PLS synchrotron X-rays
Ultra-high resolution radiographs can be obtained using synchrotron X-rays. A collaboration team consisting of K-JIST, POSTECH and YUMC has recently commissioned a new beamline (5C1) at Pohang Light Source (PLS) in Korea for medical applications using phase contrast radiology. Relatively simple image acquisition systems were set up on 5C1 beamline, and imaging studies were performed for resolution test patterns, mammographic phantom, and animals. Resolution test patterns and mammographic phantom images showed much better image resolution and quality with the 5C1 imaging system than the mammography system. Both fish and mouse images with 5C1 imaging system also showed much better image resolution with great details of organs and anatomy ...
2001-01-01
Clinical implementation of a convolution based algorithm for 3D treatment planning
International Nuclear Information System (INIS)
Purpose/Objective: With the advent of computed tomography and magnetic resonance imaging, the three dimensional representation of the patient anatomy has become an invaluable resource for better diagnosis and delineation of the target volume and sensitive structures in radiation therapy. Although the therapeutic linear accelerator industry has made available highly sophisticated equipment, the aggressiveness in dose prescription and delivery has to be complimented by accurate dose computation methods. We have adopted a convolution/superposition algorithm for the calculation of absolute dose that fully accounts for the external shape and internal structure of the patient for photon treatment radiotherapy. In this paper, we will discuss the principles of the convolution algorithm and we will show how the computed dose compares to clinically relevant treatment techniques. Materials and Methods: A computer controlled data acquisition system and a ...
UK PubMed Central (United Kingdom)
Optical coherence microscopy (OCM) is a promising technique or high resolution cellular imaging in human tissues. An OCM system for high-speed en face cellular resolution imaging...Full Text Available
2010-03-01
Diagnostic radiology: An Anglo-American textbook of imaging
Energy Technology Data Exchange (ETDEWEB)
This multiauthored text is aimed particularly toward the resident or registrar training in diagnostic radiology. This is a text book on the entire scope of diagnostic imaging. It includes techniques and imaging modalities of all the systems, head, face and neck. The book covers the entire gamut of diagnostic radiology.
1986-01-01
CHAPLET-3D results for the 3-D extension C5G7 Mox benchmarks
Energy Technology Data Exchange (ETDEWEB)
The 3-dimensional (3D) extension C5G7 MOX benchmark problems were solved by CHAPLET-3D code which is based on the idea of dynamic linkage of the multi-plane method of characteristics solutions. The benchmark results are quite accurate in comparison with the reference solutions, independently of the axial solver incorporated in the CHAPLET-3D code. (author)
2005-07-01
Portal localization images using computed radiography for high-energy electron beam therapy
Energy Technology Data Exchange (ETDEWEB)
Portal localization images for high-energy electron beam therapy are necessary to confirm the treatment field by comparing them with a simulation image obtained before treatment or portal verification images after treatment. In this study, portal localization images were acquired using the computed radiography (CR) system and bremsstrahlung X-rays generated in the electron beam irradiations. All images obtained with phantom and the irradiations of in the electron energy of 8, 10, 12 and 15 MeV were feasible for clinical use. The CR system used in this study included general diagnostic imaging cassette and storage phosphor plate, but none of other special devices. The system can usually supply portal localization images, which maintains the quality assurance of high-energy ...
2002-09-01
Sunyaev-Zeldovich profiles for clusters and groups of galaxies
The Sunyaev-Zeldovich (SZ) effect gives a measure of the thermal energy and electron pressure in groups and clusters of galaxies. In the near future SZ surveys will map hundreds of systems, shedding light on the pressure distribution in the systems. The thermal energy is related to the total mass of a system of galaxies, but it is only a projection that is observed through the SZ effect. A model for the 3D distribution of pressure is needed to link the SZ signal to the total mass of the system. In this work we construct an empirical model for the 2D and 3D SZ profile, and compare it to a set of realistic high resolution SPH simulations of galaxy clusters and groups, and to a stacked SZ profile for massive clusters derived from WMAP data. Furthermore, we combine observed temperature profiles with dark matter potentials to ...
2007-01-01
CR portal imaging; A linac graphy using storage phosphor imaging systems
Energy Technology Data Exchange (ETDEWEB)
In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In ...
1992-07-01
Development of new CAD system for steel structures of nuclear power plants
Energy Technology Data Exchange (ETDEWEB)
IHI has developed a new Three-Dimensional Computer-Aided Design (3D-CAD) system to improve the design efficiency and quality of the steel structure of nuclear power plants. This system covers every design phase from the initial arrangement of structure to the production design sharing the same database. The system incorporates the design rules and professional expertise of designers, and enable easy and efficient design. The system can easily generate the three-dimensional data for structures, model data for stress analyses and composite arrangement data. The system has already been applied to several plants under construction and has achieved excellent results. The outline of the new CAD system is introduced. (author)
1999-09-01
Modified-VSIMM algorithm with an application to the naval fire control technology
British Library Electronic Table of Contents (United Kingdom)
A modified variable structure interacting multiple model (M-VSIMM) estimator for complex hybrid maneuver target tracking is presented. The M-VSIMM could potentially be applied to fire control systems (FCS) used on warships. Target model groups were designed using 3D dimensional dynamic target models. Optimal model group selection logic was proposed, contrary to the activation and termination logic in the original VSIMM. The system will respond faster with optimal model group selection logic. After performing simulations, the tracking performances of the Kalman, ?-?(-?), VDIE, IMM and M-VSIMM filters were compared under various maneuvering conditions.
2011-01-01
Development of a chemically assisted micro-beam etching system for three-dimensional microanalysis
Energy Technology Data Exchange (ETDEWEB)
A chemically assisted micro-beam etching system for 3D microanalysis was designed. Using chemically assisted ion beam etching (CAIBE) method with FIB shave-off scanning, about several hundred micrometers clean cross-section will be acquired in a few hours. We use focused ion beam (FIB) and electron beam (EB) as micro-beams, halogen or halide mainly as reactive gases. The apparatus was manufactured based on this concept. We found that the FIB, Q-MS and SED worked as expected. The instrumentation has been completed.
2003-01-15
Development of the high sensitivity real-time neutron radiography for low-flux neutron sources
Energy Technology Data Exchange (ETDEWEB)
The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the ...
1994-08-01
Development of the high sensitivity real-time neutron radiography for low-flux neutron sources
International Nuclear Information System (INIS)
The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the ...
1994-01-01
High-resolution beta imaging; L'imagerie beta haute resolution
Energy Technology Data Exchange (ETDEWEB)
For many years, {beta} radioactivity has been used to label molecules and follow them in various biological processes. {beta} imaging is obtained by autoradiography. Classically made on films or on photographic emulsions, autoradiography is now supplanted by radio-imagers which are very performing. The phosphor-imager, {beta}-imager and {mu}-imager are the systems mainly used today and their operating principles and properties are compared. The great advantages of these imagers are: their rapidity to obtain results and their reliability for absolute quantification. All emitters ({beta}{sup -}, {beta}{sup -} -{gamma} and {beta}{sup +}) are detectable as well as the gamma emitters of nuclear medicine, by means of their low energy electrons ejected during y emission. Phosphor-imager is well suited to energetic tracers and ...
2007-04-15
International Nuclear Information System (INIS)
Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and the screen-film system was determined for phase imaging of ...
2002-03-01
Diagnosis for the cancer extension of cholangiocarcinoma. The current status
International Nuclear Information System (INIS)
Described is the diagnosis for the cancer extension of cholangiocarcinoma by various imaging techniques and processes to support the current surgical procedure based on preoperative biliary drainage. The cancer tends to locally extend horizontally and/or vertically and its diagnosis is important for surgical indication. For the indication, multi-detector raw CT (MDCT) and MR cholangio-pancreatography (MRCP) are useful and particularly, the former can give multi-phase (arterial, portal and delayed) images to reconstruct multiplanar (MPR) and CT angiographic 3D images, which have made the previous invasive examinations like angiography and percutaneous transportal contrasting unnecessary. MDCT and MRCP can almost complete the diagnosis of the extension. The operative procedure is decided dependently on the site of the lesion, and of which diagnosis, whether it is hepatic hilar/on ...
2010-07-01
Trabecular scaffolds created using micro CT guided fused deposition modeling
British Library Electronic Table of Contents (United Kingdom)
Free form fabrication and high resolution imaging techniques enable the creation of biomimetic tissue engineering scaffolds. A 3D CAD model of canine trabecular bone was produced via micro CT and exported to a fused deposition modeler, to produce polybutylene terephthalate (PBT) trabeculated scaffolds and four other scaffold groups of varying pore structures. The five scaffold groups were divided into subgroups (n=6) and compression tested at two load rates (49?N/s and 294?N/s). Two groups were soaked in a 25??C saline solution for 7?days before compression testing. Micro CT was used to compare porosity, connectivity density, and trabecular separation of each scaffold type to a canine trabecular bone sample. At 49?N/s the dry trabecular scaffolds had a compressive stiffness of 4.94?1.19?MP...
2008-01-01
Three-dimensional, three-component wall-PIV
Energy Technology Data Exchange (ETDEWEB)
This paper describes a new time-resolved three-dimensional, three-component (3D-3C) measurement technique called wall-PIV. It was developed to assess near wall flow fields and shear rates near non-planar surfaces. The method is based on light absorption according to Beer-Lambert's law. The fluid containing a molecular dye and seeded with buoyant particles is illuminated by a monochromatic, diffuse light. Due to the dye, the depth of view is limited to the near wall layer. The three-dimensional particle positions can be reconstructed by the intensities of the particle's projection on an image sensor. The flow estimation is performed by a new algorithm, based on learned particle trajectories. Possible sources of measurement errors related to the wall-PIV technique are analyzed. The accuracy analysis was based on single particle experiments and a three-dimensional artificial data set simulating a rotating ...
2010-06-15
Airbags to Martian Landers: Analyses at Sandia National Laboratories
Energy Technology Data Exchange (ETDEWEB)
A new direction for the national laboratories is to assist US business with research and development, primarily through cooperative research and development agreements (CRADAs). Technology transfer to the private sector has been very successful as over 200 CRADAs are in place at Sandia. Because of these cooperative efforts, technology has evolved into some new areas not commonly associated with the former mission of the national laboratories. An example of this is the analysis of fabric structures. Explicit analyses and expertise in constructing parachutes led to the development of a next generation automobile airbag; which led to the construction, testing, and analysis of the Jet Propulsion Laboratory Mars Environmental Survey Lander; and finally led to the development of CAD based custom garment designs using 3D scanned images of the human body. The structural analysis of these fabric structures is described as well as a ...
1994-03-01
British Library Electronic Table of Contents (United Kingdom)
The purpose of this study was to compare 2 adaptive radiotherapy strategies with helical tomotherapy. A patient having mesothelioma with mediastinal nodes was treated using helical tomotherapy with pretreatment megavoltage CT (MVCT) imaging. Gross tumor volumes (GTVs) were outlined on every MVCT study. Two alternatives for adapting the treatment were investigated: (1) keeping the prescribed dose to the targets while reducing the dose to the OARs and (2) escalating the target dose while maintaining the original level of healthy tissue sparing. Intensity modulated radiotherapy (step-and-shoot IMRT) and 3D conformal radiotherapy (3DCRT) plans for the patient were generated and compared. The primary lesion and nodal mass regressed by 16.2% and 32.5%, respectively. Adapted GTVs and reduced plan...
2009-01-01
MR imaging in neuroborreliosis of the cervical spinal cord
Energy Technology Data Exchange (ETDEWEB)
The central nervous system is involved in 10-20% of cases in Lyme disease. The neurological symptoms, time course of the disease and imaging findings are multifaceted. We report two patients with cervical radiculitis. Magnetic resonance imaging revealed strong enhancement of the cervical nerve roots on contrast-enhanced T1-weighted images. These imaging patterns of borrelia-associated radiculitis have not been reported before. Knowledge of these imaging features may help to diagnose neuroborreliosis, which presents with non-specific symptoms. (orig.)
2004-11-01
Dual-channel imaging system for singlet oxygen and photosensitizer for PDT
UK PubMed Central (United Kingdom)
A two-channel optical system has been developed to provide spatially resolved simultaneous imaging of singlet molecular oxygen (1O2) phosphorescence and photosensitizer (PS) fluorescence...Full Text Available
Energy Technology Data Exchange (ETDEWEB)
Detailed quantitative sequence stratigraphic analysis and three-dimensional (3-D) modeling of the fluvio-deltaic Pikeville, Hyden, and four Corners formations of the Breathitt Group, eastern Kentucky, indicate that it is possible to make confident deterministic correlations of sand bodies at offshore development well spacings. The key to high-confidence correlation is the delineation of the 3-D architecture of third-order composite sequences, which are seismically mappable, and the recognition of internal fourth-order sequences, which are stacked into lowstand, transgressive, and highstand sequence sets. Volumetric partitioning of reservoir sand bodies between systems tracts and sequences allows prediction of channel sandstone geometries and channel: crevasse splay ratios. Furthermore, channel-fill type is predictable from the sequence stratigraphy. Within 13 studied fourth-order ...
1993-09-01
MER-DIMES : a planetary landing application of computer vision
During the Mars Exploration Rovers (MER) landings, the Descent Image Motion Estimation System
2005-01-01
International Nuclear Information System (INIS)
The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)
2004-04-01
Growth, Characterization and Device Development in ...
... eV. In some instances the spontaneous radiation from a free electron laser system was employed to obtain images. The ...
1998-03-01
DVRPC 2010 Digital Orthoimagery - Mr.SID County Mosaics
... image overlap between adjacent tiles. Orthoimagery processed by BAE Systems....
An Integrated Approach to Intelligent Systems
... order probabilistic modelling, multisensor monitoring of ... object recognition, image registration and point ... of the Berkeley Continuous Media Toolkit. ...
2002-01-01
Real-time neutron coded aperture imaging: A technique for nondestructive three-dimensional imaging
Energy Technology Data Exchange (ETDEWEB)
Neutron Coded Aperture Imaging is a nondestructive imaging technique that utilizes neutrons scattered from an object through specially designed apertures. Coded Aperture Imaging is an alternative technique to Computed Tomography for three-dimensional imaging. Coded Aperture Imaging has the advantage that all of the three-dimensional information is contained in a single image, whereas Computed Tomography requires several images or projections. This technique has been implemented by other using photographic film as an image recording medium and optical reconstruction or decoding of the images. In this work, the possibility of using a real-time neutron video camera to record the images, followed by digital decoding methodology has been investigated. Because only a small fraction of ...
1992-01-01
Subsurface imaging using the spectral polarization difference technique and NIR illumination
Energy Technology Data Exchange (ETDEWEB)
A subsurface imaging system is utilized to test the ability of the spectral polarization difference imaging technique for deep subsurface imaging in tissues. The illumination of the system is derived from compact class III lasers in the red and NIR spectral region and, alternatively, from a white light source and selection of the appropriate illumination wavelength using band-pass optical filters. The experimental results demonstrate detection and imaging of a high-scattering object located up to 1.5 cm underneath the surface of a host chicken tissue.
1999-01-26
Neutron imaging system for neutron tomography, radiography, and beam diagnostics
Energy Technology Data Exchange (ETDEWEB)
A neutron imaging system (NIS) has been recently installed at the University of Texas TRIGA reactor facility. The imaging system establishes new capabilities for beam diagnostics at the Texas Cold Neutron Source (TCNS) for real-time neutron radiography (RTNR) and for neutron computed tomography (NCT) research. The NIS will also be used for other research projects. The system consists of two subsystems as follows: (1) Thomson 9-in. neutron image intensifier (NII) tube sensitive to cold, thermal, and epithermal neutrons, (2) image-processing unit consisting of vidicon camera, two high-resolution monitors, image enhancement and measurement processor, and video printer. The NIS is installed at the cold neutron beam of the TCNS for testing and cold neutron beam diagnostics.
1995-12-31
Investigation of Two-Phase Flow Regime Maps for Development of Thermal-Hydraulic Analysis Codes
Energy Technology Data Exchange (ETDEWEB)
This reports is a literature survey on models and correlations for determining flow pattern that are used to simulate thermal-hydraulics in nuclear reactors. Determination of flow patterns are a basis for obtaining physical values of wall/interfacial friction, wall/interfacial heat transfer, and droplet entrainment/de-entrainment. Not only existing system codes, such as RELAP5-3D, TRAC-M, MARS, TRACE, CATHARE) but also up-to-date researches were reviewed to find models and correlations
2010-04-15
Interventional MR imaging: Clinical results obtained with a 1.5 Tesla system
International Nuclear Information System (INIS)
The clinical feasibility of using interventional examination techniques was tested with an equipment combining fluoroscopy and MR imaging. This hybrid system showed to be of advantage in a great number of interventional examinations. The 1.5 Tesla magnet proved to be superior to open MR scanning systems in terms of image quality and scanning times. (orig.).
Method for the reduction of image content redundancy in large image databases
Energy Technology Data Exchange (ETDEWEB)
A method of increasing information content for content-based image retrieval (CBIR) systems includes the steps of providing a CBIR database, the database having an index for a plurality of stored digital images using a plurality of feature vectors, the feature vectors corresponding to distinct descriptive characteristics of the images. A visual similarity parameter value is calculated based on a degree of visual similarity between features vectors of an incoming image being considered for entry into the database and feature vectors associated with a most similar of the stored images. Based on said visual similarity parameter value it is determined whether to store or how long to store the feature vectors associated with the incoming image in the database.
2010-03-02
Implementation of improved interactive image analysis at the Advanced Photon Source (APC) linac.
Energy Technology Data Exchange (ETDEWEB)
An image-analysis system, based on commercially available data visualization software (IDL [1]), allows convenient interaction with image data while still providing calculated beam parameters at a rate of up to 2 Hz. Image data are transferred from the IOC to the workstation via EPICS [2] channel access. A custom EPICS record was created in order to overcome the channel access limit of 16k bytes per array. The user can conveniently calibrate optical transition radiation (OTR) and fluorescent screens, capture background images, acquire and average a series of images, and specify several other filtering and viewing options. The images can be saved in either IDL format or APS-standard format (SDDS [3]), allowing for rapid postprocessing of image data by numerous other software tools.
1998-09-11
International Nuclear Information System (INIS)
In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In ...
1992-01-01
MR imaging of musculoskeletal trauma to the pelvis and the lower limb
Energy Technology Data Exchange (ETDEWEB)
Magnetic resonance imaging can be used in the trauma setting to detect fractures and associated soft tissue injuries of the musculoskeletal system. Magnetic resonance imaging complements plain radiography and CT for evaluating cancellous bone, cartilage and growth-plate injuries, and intra- and extraarticular supporting soft tissue structures. This review outlines typical applications and imaging consideration for injuries of the pelvis and lower extremity. (orig.) With 12 figs., 78 refs.
1999-03-01
MTF analysis of the near-real time neutron radiography facility at MURR
International Nuclear Information System (INIS)
Several neutron radiography systems designed to view transient processes on a real-time basis have been developed. With the advent of these different real-time systems comes the necessity to develop a means to quantitatively evaluate and compare these systems. A suitable method for measuring the resolution capabilities of the image-forming system is the determination of the modulation transfer function (MTF). The MTF is a measure of an imaging system's ability to reproduce the spatial frequencies present in an image. The system in use at the University of Missouri Research Reactor is described. (Auth.).
1981-12-01
Development of a dual-detector X-ray imaging system for phase retrieval study
International Nuclear Information System (INIS)
Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of ...
2007-01-01
International Nuclear Information System (INIS)
Purpose. To validate a protocol for creating virtual models to be used in the construction of solid prototypes useful for the planning-simulation of maxillo-facial surgery, in particular for very complex anatomical and pathologic problems. To optimize communications between the radiology, engineering and surgical laboratories. Methods and materials. We studied 16 patients with different clinical problems of the maxillo-facial district. Exams were performed with multidetector computed tomography (MDCT) and single slice computed tomography (SDCT) with axial scans and collimation of 0.5-2 mm, and reconstruction interval of 1 mm. Subsequently we performed 2D multiplanar reconstructions and 3D volume-rendering reconstructions. We exported the DICOM images to the engineering laboratory, to recognize and isolate the bony structures by software. With these data the solid prototypes were generated using stereolitography. To date, ...
2005-11-01
3D Fourier synthesis of a new X-ray picture identical in projection to a previous picture
Energy Technology Data Exchange (ETDEWEB)
A central problem in diagnostic radiology is to compare a new X-ray picture with a previous picture and from this comparison be able to decide if anatomical changes have occurred in the patient or not. It is of primary interest that these pictures are identical in projection. If not it is difficult to decide with confidence if differences between the pictures are due to anatomical changes or differences in their projection geometry. In this thesis we present a non invasive method that makes it possible to find the relative changes in the projection geometry between the exposure of a previous picture and a new picture. The method presented is based on the projection slice theorem (central section theorem). Instead of an elaborate search for a single new picture a pre-planned set of pictures are exposed from a circular orbit above the patient. By using 3D Fourier transform techniques we are able to synthesize a new X-ray picture from this set of ...
1993-11-01
Photochromes for Optical Memory
International Science & Technology Center (ISTC)
Photochromes for New Generation of Highly Efficient Computers with Three Dimensional (3D) Optical Memory
... 2009) Arrhythmia Electrophysiological Study and Catheter Ablation with 3D Mapping (Mercy Hospital, Miami, FL, 11/15/2007) ...
A feedforward architecture accounts for rapid categorization
UK PubMed Central (United Kingdom)
Primates are remarkably good at recognizing objects. The level of performance of their visual system and its robustness to image degradations still surpasses the best computer vision systems despite...Full Text Available
2007-04-10
A PC-Based Imaging System for the Naval Postgraduate ...
... 1 I3a TYPE OF REPORT 1 3b TIME COVERED ... Measured by this standard the system provides good results; it ... did not fully meet all the standards or ...
1989-09-01
International Nuclear Information System (INIS)
An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector ...
1996-01-01
Ultrashort echo time MRI of cortical bone at 7 tesla field strength: A feasibility study
British Library Electronic Table of Contents (United Kingdom)
AbstractPurpose: To implement and examine the feasibility of a three-dimensional (3D) ultrashort TE (UTE) sequence on a 7 Tesla (T) clinical MR scanner in comparison with 3T MRI at high isotropic resolution. Materials and Methods: Using an in-house built saddle coil at both field strengths we have imaged mid-diaphysial sections of five fresh cadaveric specimens of the distal tibia. An additional in vivo scan was performed at 7 Tesla using a quadrature knee coil. Results: Using the same type of saddle coil at both field strengths, a significant increase in SNR at 7T compared with 3T (factor 1.7) was found. Significantly shorter T2* values were found at the higher field strength (T2* = 552.2 126 s at 7T versus T2* = 1163 391 s at 3T). Conclusion: UHF MRI at 7T has great potential for imaging...
2011-01-01
Die Backside FIB Preparation for Identification and Characterization of Metal Voids
Energy Technology Data Exchange (ETDEWEB)
Both the increased complexity of integrated circuits, resulting in six or more levels of integration, and the increasing use of flip-chip packaging have driven the development of integrated circuit (IC) failure analysis tools that can be applied to the backside of the chip. Among these new approaches are focused ion beam (FIB) tools and processes for performing chip edits/repairs from the die backside. This paper describes the use of backside FIB for a failure analysis application rather than for chip repair. Specifically, they used FIB technology to prepare an IC for inspection of voided metal interconnects (lines) and vias. Conventional FIB milling was combined with a super-enhanced gas assisted milling process that uses XeF{sub 2} for rapid removal of large volumes of bulk silicon. This combined approach allowed removal of the TiW underlayer from a large number of Ml lines simultaneously, enabling rapid localization and plan view imaging of voids in lines and ...
1999-07-28
Computational models of stellar collapse and core-collapse supernovae
International Nuclear Information System (INIS)
Core-collapse supernovae are among Nature's most energetic events. They mark the end of massive star evolution and pollute the interstellar medium with the life-enabling ashes of thermonuclear burning. Despite their importance for the evolution of galaxies and life in the universe, the details of the core-collapse supernova explosion mechanism remain in the dark and pose a daunting computational challenge. We outline the multi-dimensional, multi-scale, and multi-physics nature of the core-collapse supernova problem and discuss computational strategies and requirements for its solution. Specifically, we highlight the axisymmetric (2D) radiation-MHD code VULCAN/2D and present results obtained from the first full-2D angle-dependent neutrino radiation-hydrodynamics simulations of the post-core-bounce supernova evolution. We then go on to discuss the new code Zelmani which is based on the open-source HPC Cactus framework and provides a scalable AMR approach for ...
2009-07-01
International Nuclear Information System (INIS)
To assess the diagnostic capability Fuji computed radiography (FCR) using a dual side reading system was compared to the conventional radiography using a film-screen system. Twenty-eight patients with lung cancer were examined with a new FCR system (FCR 5501D) and a conventional screen-film system concurrently. FCR utilizes a reading system that detects emissions from dual sides of imaging plate. Chest X-rays were obtained with same exposure factors in both systems. Image qualities of both systems were compared by two radiologists using a five-level score. There were no lesion that FCR images were inferior to film-screen images. The frequency of score +1 or +2 that FCR images were superior to film-screen images was ...
2003-02-01
Energy Technology Data Exchange (ETDEWEB)
The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting ...
1984-09-01
International Nuclear Information System (INIS)
The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting ...
1984-01-01
A high-sensitivity small animal SPECT system
International Nuclear Information System (INIS)
Medical imaging using single gamma-ray-emitting radionuclides typically makes use of parallel hole collimators or pinholes in order to achieve good spatial resolution. However, a tradeoff in sensitivity is inherent in the use of a collimator, and modern preclinical single photon emission computed tomography (SPECT) systems detect a very small fraction of emitted gamma rays, often less than 0.1%. A system for small animal SPECT imaging which uses no collimators could potentially achieve very high sensitivity-several tens of percent-with reasonably sized detectors. This would allow two significant improvements in preclinical studies: images could be obtained more rapidly, allowing higher throughput for screening applications, or for dynamic processes to be observed with very good time resolution; and images could be obtained with less radioactive tracer, making ...
2009-03-07
Approximate fuzzy C-means (AFCM) cluster analysis of medical magnetic resonance image (MRI) data
International Nuclear Information System (INIS)
The authors describe the application of an approximate fuzzy C-means (AFCM) clustering algorithm as a data dimension reduction approach to medical magnetic resonance images (MRI). Image data consisted of one T1-weighted, two T2-weighted, and one T2*-weighted (magnetic susceptibility) image for each cranial study and a matrix of 10 images generated from 10 combinations of TE and TR for each body lymphoma study. All images were obtained with a 1.5 Tesla imaging system (GE Signa). Analyses were performed on over 100 MR image sets with a variety of pathologies. The cluster analysis was operated in an unsupervised mode and computational overhead was minimized by utilizing a table look-up approach without adversely affecting accuracy. Image data were first segmented into 2 coarse clusters, each of which ...
Visualization of liquid metal two-phase flow by a real time neutron radiography system
Energy Technology Data Exchange (ETDEWEB)
In order to understand the detail transient two-phase flow structure, more advanced two-phase flow instrumentation is required. One advanced technique for flow visualization is real-time neutron radiography. Reconstruction method of visualized radiographic image of liquid metal two-phase flow generated by the real-time neutron radiography system is proposed in this paper. Image processing techniques for noise reduction and image enhancement are discussed in detail. (author).
1995-11-01
Visualization of liquid metal two-phase flow by a real time neutron radiography system
International Nuclear Information System (INIS)
In order to understand the detail transient two-phase flow structure, more advanced two-phase flow instrumentation is required. One advanced technique for flow visualization is real-time neutron radiography. Reconstruction method of visualized radiographic image of liquid metal two-phase flow generated by the real-time neutron radiography system is proposed in this paper. Image processing techniques for noise reduction and image enhancement are discussed in detail. (author).
1995-01-01
Principium research of real-time neutron radiography in No. 300 reactor
International Nuclear Information System (INIS)
The characteristics of real-time neutron radiography are described briefly in this paper, and the acquirement of neutron flux, the selection of convertor and the structure of the twilight imaging system and the image-sampling and image-processing system in SPRR-300 reactor are also analyzed detailedly. The experimental result of real-time neutron radiograph is too analyzed in this paper
2002-12-01
Neutron radiography with the cyclotron, 6
International Nuclear Information System (INIS)
The image processing system for the dynamic neutron radiography has been developed. It is based on the hardware subset, composed by the method of the pipe-line and use of algorithm of local statistics. The processing speed per one pixel is shorter than 100 n sec and video-rate processing can be executed on it. Some image processes for improving the quality of the real-time neutron image, noise reduction and contrast stretching would be attempted by the use of this system. (author).
1988-01-01
Reduction of fluoroscopic exposure for the air-contrast barium enema
Energy Technology Data Exchange (ETDEWEB)
In a fluoroscopic imaging system, image quality and patient dose are both affected by the optical system linking the image intensifier with the video camera. The effect on patient exposure of increasing the optical iris aperture size over that required for other procedures performed on the same imaging system was investigated for the air-contrast barium enema examination. Using a large-area transmission ionisation chamber to monitor the Roentgen-area-product of entrance exposure, a decrease in fluoroscopic radiation of greater than 50% was clinically documented for a fluoroscopic system utilising kVp and mA variable automatic brightness control. For this iris change, the video image was of acceptable quality for positioning and monitoring the patient, and no deleterious effect was detected in the ...
1983-11-01
Volume 2- Technical Approach - IMAGE Science Center - NASA
Power system analysis shows the output from the solar arrays varies as a function .... Each array corresponds to a raw image browse product, which is generated by .... low outgassing, ability to withstand long-term exposure to the space ...
UK PubMed Central (United Kingdom)
ObjectivesWe have developed an image-guided surgery system based on invisible near-infrared (NIR) fluorescent light. Presently, the only clinically-available NIR...Full Text Available
2009-07-01
Radio frequency noise from an MLC: a feasibility study of the use of an MLC for linac-MR systems
UK PubMed Central (United Kingdom)
Currently several groups are actively researching the integration of a megavoltage teletherapy unit with magnetic resonance (MR) imaging for real-time image-guided radiotherapy. The use of a...Full Text Available
2010-02-21
Early Detection of Bronchial Lesions Using Lung Imaging Fluorescence Endoscope
UK PubMed Central (United Kingdom)
The performance of the Lung Imaging Fluorescence Endoscope (LIFE) system was compared with conventional bronchoscopy in 158 patients: 68 patients with invasive cancer, 42 patients with abnormal sputum...Full Text Available
1999-01-01
We describe a closed-loop brain-computer interface that re-ranks an image database by iterating between user generated 'interest' scores and computer vision generated visual similarity measures. The interest scores are based on decoding the electroencephalographic (EEG) correlates of target detection, attentional shifts and self-monitoring processes, which result from the user paying attention to target images interspersed in rapid serial visual presentation (RSVP) sequences. The highest scored images are passed to a semi-supervised computer vision system that reorganizes the image database accordingly, using a graph-based representation that captures visual similarity between images. The system can either query the user for more information, by adaptively resampling the database to create additional RSVP sequences, or it can converge to a ...
2011-05-12
A Software System for Data Analysis in Automated DNA?Sequencing
UK PubMed Central (United Kingdom)
Software for gel image analysis and base-calling in fluorescence-based sequencing consisting of two primary programs, BaseFinder and GelImager, is described. BaseFinder is a framework for trace processing,...Full Text Available
1998-06-01
Quantitative imaging of turbulent and reacting flows
Energy Technology Data Exchange (ETDEWEB)
Quantitative digital imaging, using planar laser light scattering techniques is being developed for the analysis of turbulent and reacting flows. Quantitative image data, implying both a direct relation to flowfield variables as well as sufficient signal and spatial dynamic range, can be readily processed to yield two-dimensional distributions of flowfield scalars and in turn two-dimensional images of gradients and turbulence scales. Much of the development of imaging techniques to date has concentrated on understanding the requisite molecular spectroscopy and collision dynamics to be able to determine how flowfield variable information is encoded into the measured signal. From this standpoint the image is seen as a collection of single point measurements. The present effort aims at realizing necessary improvements in signal and spatial dynamic range, signal-to-noise ratio and ...
1993-12-01
International Nuclear Information System (INIS)
The DNA double-strand break (DSB) damage response induced by high energy charged particles on lung fibroblast cells embedded in a 3-dimensional (3-D) collagen tissue equivalents was investigated using antibodies to the DNA damage response proteins gamma-histone 2AX (#gamma#-H2AX) and phosphorylated DNA-PKcs (p-DNA-PKcs). 3-D tissue equivalents were irradiated in positions across the linear distribution of the Bragg curve profiles of 307.7 MeV/nucleon, 556.9 MeV/nucleon, or 967.0 MeV/nucleon "5"6Fe ions at a dose of 0.30 Gy. Patterns of discrete DNA damage streaks across nuclei or saturated nuclear damage were observed, with saturated nuclear damage being more predominant as samples were positioned closer to the physical Bragg peak. Quantification of the DNA damage signal intensities at each distance for each of the examined energies revealed a biological Bragg curve profile with a pattern of DNA damage ...
2010-03-01
Hybrid Camera Surveillance System Using Robust Human Detection
We propose a novel surveillance system that uses hybrid camera network. The system contains a panorama camera and PTZ cameras to take the wide range images and face images at high enough resolution for identification tasks. The robust human detection methods include robust background subtraction method (RRC), skin color segmentation and face tracking method. First, the system detects persons from a panorama image, and then the detailed face images are obtained with the PTZ cameras. The PTZ cameras can track the faces using the four directional features and the relaxation matching. In addition, the system has automatic camera position calibration feature. Thus, the user can use the system without any troublesome settings.
2007-01-01
Energy Technology Data Exchange (ETDEWEB)
In this paper, the multisource geoscientific data, such as TM data, NOAA data, the data of Bouguer gravity anomaly and aeromagnetic anomaly, the multisource geophysical processing methods, such as upward continuations, vertical derivative and gradient image, and synthetic image processing method - remote sensing image processing and geophysical image processing under I{sup 2}S600, are used to study the reverse faults or thrusts in the southern margin of Ordos basin, China. On the basis of these results and with geological investigation in the field, the authors have determined three thrust compression systems, named EW thrust compression system, NE thrust compression system and NW thrust compression system. These three systems reveal the regularity of geological structural evolution in the southern ...
1996-08-01
Improved quadrant anode image sensor with microchannel plates
Energy Technology Data Exchange (ETDEWEB)
We describe a position-sensitive event-counting microchannel plate detector with a quadrant anode readout system that combines the advantages of several centroid-finding readout techniques. The relative amount of charge collected by each quadrant of the anode mounted behind the output side of the microchannel plate is used to localize each event. The position-sensitive area is about 80% of the active microchannel plate surface. By changing a single voltage a remote-controlled image magnification can be achieved. Due to a correction function that minimizes image distortions the imaging characteristics of this low-cost readout system are similar to those of expensive resistive anodes.
1987-11-15
Development of high resolution imaging detectors for X-ray astronomy
Energy Technology Data Exchange (ETDEWEB)
High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.
1985-03-01
Development of high resolution imaging detectors for X-ray astronomy
International Nuclear Information System (INIS)
High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.
1985-01-01
An improved quadrant anode image sensor with microchannel plates
International Nuclear Information System (INIS)
We describe a position-sensitive event-counting microchannel plate detector with a quadrant anode readout system that combines the advantages of several centroid-finding readout techniques. The relative amount of charge collected by each quadrant of the anode mounted behind the output side of the microchannel plate is used to localize each event. The position-sensitive area is about 80% of the active microchannel plate surface. By changing a single voltage a remote-controlled image magnification can be achieved. Due to a correction function that minimizes image distortions the imaging characteristics of this low-cost readout system are similar to those of expensive resistive anodes. (orig.).
1987-11-01
An improved quadrant anode image sensor with microchannel plates
We describe a position-sensitive event-counting microchannel plate detector with a quadrant anode readout system that combines the advantages of several centroid-finding readout techniques. The relative amount of charge collected by each quadrant of the anode mounted behind the output side of the microchannel plate is used to localize each event. The position-sensitive area is about 80% of the active microchannel plate surface. By changing a single voltage a remote-controlled image magnification can be achieved. Due to a correction function that minimizes image distortions the imaging characteristics of this low-cost readout system are similar to those of expensive resistive anodes.
1987-11-01
Gastrointestinal radiography using Fuji computed radiography (FCR)
International Nuclear Information System (INIS)
Initial clinical experience in gastrointestinal radiography using Fuji Computed Radiography(FCR) system was reported. Image quality of conventional film/screen radiography and FCR system on upper GI series and barium enema was compared. Reflecting wide dynamic range of the system, improved image quality was confirmed, particularity in visibility of fine mucosal pattern(area gastricae), folds and overall contour. High sensor sensitivity of the system could reduce radiation dose requirement significantly. Diagnostically acceptable images were obtained with approximately 1/5 of routine dose for conventional radiography except in cases of lateral view of the rectum. (author).
1985-01-01
Application of the neutron television fluoroscopic system to neutron computed tomography
Energy Technology Data Exchange (ETDEWEB)
Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter. (orig.).
1984-10-01
Application of the neutron television fluoroscopic system to neutron computed tomography
Energy Technology Data Exchange (ETDEWEB)
Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter.
1984-10-01
An application of the neutron television fluoroscopic system to neutron computed tomography
International Nuclear Information System (INIS)
Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter. (orig.).
1984-10-01
Clinical trial of NMR-CT, (4). Clinical evaluation of hybrid image
Energy Technology Data Exchange (ETDEWEB)
In our evaluation we utilized the Asahi Mark-J NMR-CT system, with a resistive vertical quadrupolar electromagnet (0.1 Tesla) and a proton resonance frequency of 4.5 MHz. Our main imaging methods are the inversion-recovery or IR, saturation-recovery, or SR, and calculated T/sub 1/. Difference, or D images, constructed by subtracting the data of the IR signal from that of the SR signal, have also been obtained in some cases. The system allows averaging of raw data. Hybrid images were constructed from two or more images to obtain clear definition of areas of interest. By using the hybrid image, several tissues of different relaxation times can be shown in the same image. Application in our study of the newly developed hybrid image indicates its importance in the detection and diagnosis of lesion, ...
1985-01-01
ITER Blanket First Wall (WBS 1.6{sub 1}A)
Energy Technology Data Exchange (ETDEWEB)
International Thermonuclear Experimental Reactor (ITER) project is the international collaboration one for the commercialization of nuclear fusion energy through the technical and engineering verification. In ITER project, we plan to procure the blanket systems which has the risk of technology and cost when it is newly developed. We are developing the manufacturing process and joining technology for the ITER blanket to complete the procurement with qualified blanket system. To evaluate the soundness of manufacturing process, specimen and mock-up tests are being prepared. Finally, we can obtain the key technology of nuclear fusion reactor especially on the blanket design, joining and manufacturing technology through the present project and these technologies will help the construction of Korea fusion DEMO reactor and the development of commercial nuclear fusion reactor in Korea. In 1st year, through the fabrication of the Cu/SS and Be/Cu joint ...
2008-03-15
On-line video image processing system for real-time neutron radiography
Energy Technology Data Exchange (ETDEWEB)
The neutron radiography system installed at the E-2 experimental hole of the KUR (Kyoto University Reactor) has been used for some NDT applications in the nuclear field. The on-line video image processing system of this facility is introduced in this paper. A 0.5 mm resolution in images was obtained by using a super high quality TV camera developed for X-radiography viewing a NE-426 neutron-sensitive scintillator. The image of the NE-426 on a CRT can be observed directly and visually, thus many test samples can be sequentially observed when necessary for industrial purposes. The video image signals from the TV camera are digitized, with a 33 ms delay, through a video A/D converter (ADC) and can be stored in the image buffer (32 KB DRAM) of a microcomputer (Z-80) system. The digitized pictures are taken with 16 levels of ...
1983-09-15
An on-line video image processing system for real-time neutron radiography
International Nuclear Information System (INIS)
The neutron radiography system installed at the E-2 experimental hole of the KUR (Kyoto University Reactor) has been used for some NDT applications in the nuclear field. The on-line video image processing system of this facility is introduced in this paper. A 0.5 mm resolution in images was obtained by using a super high quality TV camera developed for X-radiography viewing a NE-426 neutron-sensitive scintillator. The image of the NE-426 on a CRT can be observed directly and visually, thus many test samples can be sequentially observed when necessary for industrial purposes. The video image signals from the TV camera are digitized, with a 33 ms delay, through a video A/D converter (ADC) and can be stored in the image buffer (32 KB DRAM) of a microcomputer (Z-80) system. The digitized pictures are taken with 16 levels of ...
1983-09-01
State of the art simulations of magnicon
International Nuclear Information System (INIS)
The magnicon is a highly attractive candidate to be the RF source for a future multi-Tev linear collider. Physical models and computer codes have been developed which can provide start-to-end self-consistent simulations of a magnicon, including precise simulations of the high-convergence electron gun, RF-system, magnetic system, and beam collector. The 3-D beam dynamics simulations include realistic fields, finite beam size and transverse space charge effects. The codes allow one to provide steady-state simulations of the entire tube, so as to evaluate transient process of magnicon excitation, parasitic mode self-excitation, stability analysis, and tolerance analysis. The results of the simulations are found to be in good agreement with magnicon experiments. A brief description of the physical models and simulation codes employed will be given.
2002-12-12
Development of in-vessel reflood instrumentation at ORNL
International Nuclear Information System (INIS)
A program under the sponsorship of the United States Nuclear Regulatory Commission was intiated at the Oak Ridge National Laboratory (ORNL) in late 1977. The program, Advanced Instrumentation for Reflood Studies (AIRS), is charged with developing instrumentation for measurement of in-vessel fluid phenomena in pressurized water reactor reflood facilities. The goal of the ORNL program is to develop techniques and systems for measuring fluid flow in-core, deentrainment in the upper plenum and liquid fallback from the upper plenum into the core. A large portion of the development at ORNL is devoted to the impedance probes for measurement of two-phase flow velocities and void fractions. Film probe development at ORNL is limited to adapting the present techniques to the environment of a reflood facility. As the development progresses on all the measurement techniques, ORNL will fabricate and supply instrument systems to the reflood facilities ...
2004-09-06
Development of Ultra-Fast Silicon Switches for Active X-Band High Power RF Compression Systems
Energy Technology Data Exchange (ETDEWEB)
We present the recent results of our research on the high power ultra-fast silicon RF switches. This switch is composed of a group of PIN diodes on a high purity silicon wafer. The wafer is inserted into a cylindrical waveguide under TE{sub 01} mode, performing switching by injecting carriers into the bulk silicon. Our current design uses a CMOS compatible process and the device was fabricated at SNF (Stanford Nanofabrication Facility). 300 ns switching time has been observed, while the switching speed can be improved further with 3-D device structure and faster driving circuit. Power handling capacity of the switch is at the level of 10 MW. The switch was designed for active X-band RF pulse compression systems--especially for NLC, but it is also possible to be modified for other applications and other frequencies.
2006-03-06
Application research on three-dimensional virtual mine in the framework of internet of things
British Library Electronic Table of Contents (United Kingdom)
Based on the information system characteristics of mine, proposed network architecture design of the mine property. And in this framework based on the design of three-dimensional virtual mine described the application of intelligent management platform. Three-dimensional virtual underground mine that shows the situation, the core application is through remote monitoring system of information exchange between devices (material object communication). Internet of things in the framework of mining three-dimensional virtual reconstruction of mine. On coal mine safety in the production process of human, machine and environment, control elements and their harmony and unity. 3D virtual mine management platform integrates personnel positioning, dust control, gas monitoring, roof pressure monitoring...
2011-01-01
3D transient calculations of PGV-1000 based on TRAC
Energy Technology Data Exchange (ETDEWEB)
Full text of publication follows: During calculations of SAR accidents and transients it is necessary to perform steam generator simulation. Best accuracy is 3D transient calculations presented in report. Main outcomes of work was next: 1. There was shown by analysis the applicability of code TRAC (Los-Alamos laboratory) for thermal - hydraulic calculations of horizontal steam generator PGV-1000M. Special nodalization scheme was developed for it purposes. 2. Validation and selection of thermal-hydraulic correlations for improvement of using the code at calculation PGV-1000M were performed. As result Labuntsov formula is recommended for horizontal SG. 3. Calculations of nominal mode operation of PGV-1000M for cross-verification with code STEG (Electrogorsk Research and Engineering Center EREC) during its verification were performed. Solution by TRAC was obtained for transient problem after stabilization time. 4. Development of dynamic SG model ...
2005-07-01
A Multi-Layered Image Cache for Scientific Visualization
Energy Technology Data Exchange (ETDEWEB)
We introduce a multi-layered image cache system that is designed to work with a pool of rendering engines to facilitate an interactive, frameless, asynchronous rendering environment. Our system decouples the rendering from the display of imagery. Therefore, it decouples render frequency and resolution from display frequency and resolution, and allows asynchronous transmission of imagery instead of the compute/send cycle of standard parallel systems. It also allows local, incremental refinement of imagery without requiring all imagery to be re-rendered. Images are placed in fixed position in camera (vs. world) space to eliminate occlusion artifacts. Display quality is improved by increasing the number of images. Interactivity is improved by decreasing the number of images.
2003-06-26
3D-nuclear heat generation in PCC-charcoal filter in TAPP-3 and 4
International Nuclear Information System (INIS)
This paper deals with the calculations of 3D nuclear heat generation profile in the charcoal filter and subsequently the commencement time of Primary Containment Cleanup (PCC) system of 540MWe Pressurized Heavy Water Reactor (PHWR). Fuel failure is predicted due to overheating of the fuel under loss of Coolant Accident (LOCA) without Emergency Core Cooling System (LOCA without ECCS). Subsequently fission product gasses along with water vapours are released to Reactor Building (RB) atmosphere. Plate-out and water trapping mechanism stabilizes the concentration of significant fission products i.e. radioiodines in about 4 hours before being circulated through charcoal filters of Containment Cleanup system. After cleaning up the RB atmosphere, it is discharged to outside atmosphere through stack. The isotopes of radioiodine emit beta and gamma radiations. Gamma radiations are partly ...
2006-11-13
Energy Technology Data Exchange (ETDEWEB)
This topical report is a compilation of characterizations by different disciplines of the Mississippian Ratcliffe in portions of Richland County, MT. Goals of the report are to increase understanding of the reservoir rocks, oil-in-place, heterogeneity and methods for improved recovery. The report covers investigations of geology, petrography, reservoir engineering and seismic. The Ratcliffe is a low permeability oil reservoir which appears to be developed across much of the study area and occurs across much of the Williston Basin. The reservoir has not been a primary drilling target in the study area because average reserves have been insufficient to payout the cost of drilling and completion despite the application of hydraulic fracture stimulation. Oil trapping does not appear to be structurally controlled. For the Ratcliffe to be a viable drilling objective, methods need to be developed for (1) targeting better reservoir development and (2) better completions. A geological model is ...
1998-07-01
Energy Technology Data Exchange (ETDEWEB)
A large part of mechanical and durability characteristics of cement-based materials comes from the performances of the hydrated cement, cohesive matrix surrounding the granular skeleton. Experimental studies, in situ or in laboratory, associated to models, have notably enhanced knowledge on the cement material and led to adapted formulations to specific applications or particularly aggressive environments. Nevertheless, these models, developed for precise cases, do not permit to specifically conclude for other experimental conclusions. To extend its applicability domain, we propose a new evolutive approach, based on reactive transport expressed at the microstructure scale of the cement. In a general point of view, the evolution of the solid compounds of the cement matrix, by dissolutions or precipitations, during chemical aggressions can be related to the pore solution evolution, and this one relied to the ionic exchanges with the external environment. By the utilization of a ...
2004-09-15
Diagnosis of occipital condyle fractures; Diagnostik von Frakturen der Okzipitalkondylen
Energy Technology Data Exchange (ETDEWEB)
Following the conventional X-ray diagnosis of the skull and upper cervical spine, CT proved to be the primary diagnostic method after a skull and brain injury: For all 4 cases we succeeded in detecting the occipital condyle fracture and in determing its size and location by reconstructions (coronal, sagittal, 3-D). In the case of complex occompanying injuries like soft tissue hematomas (cerebral, in the spinal cord, and the soft tissue of the neck) or for the detection of brain stem contusion, MRT had significant advantages. MRT can offer a higher image quality in soft tissue, especially in the spinal cord and the brain. (orig.) [Deutsch] Im Anschluss an die konventionelle Roentgendiagnostik des Schaedels und der Halswirbelsaeule, erwies sich die Computertomographie als primaer einzusetzendes diagnostisches Verfahren, nach erlittenem Schaedel-Hirn-Trauma. In allen Faellen gelang der exakte Frakturnachweis an den ...
1995-01-01
Towards an objective evaluation of tolerances for beam modeling in a treatment planning system
International Nuclear Information System (INIS)
The performance of a convolution/superposition based treatment planning system depends on the ability of the dose calculation algorithm to accurately account for physical interactions taking place in the tissue, key components of the linac head and on the accuracy of the photon beam model. Generally the user has little or no control over the performance of the dose calculation algorithm but is responsible for the accuracy of the beam model within the constraints imposed by the system. This study explores the dosimetric impact of limitations in photon beam modeling accuracy on complex 3D clinical treatment plans. A total of 70 photon beam models was created in the Pinnacle(TM) treatment planning system. Two of the models served as references for 6 MV and 15 MV beams, while the rest were created by perturbing the reference models in order to produce specific deviations in specific ...
2007-09-21
SUBMIT TO: AM105 CONFERENCE TITLE: Earth Observing Systems VI - NASA
BAE SYSTEMS Infrared Imaging Systems. MS 209. 2 Forbes Road. Lexington, MA 02421 -7306. (781) 863-3762. (781) 863-4809 (fax) ken.overoye @lmco.com ...
X-ray Phase Imaging Microscopy using a Fresnel Zone Plate and a Transmission Grating
International Nuclear Information System (INIS)
We report on a hard X-ray phase imaging microscopy (a phase-difference microscopy) that consists of an objective and a transmission grating. The simple optical system provides a quantitative phase image, and does not need a wave field mostly coherent on the objective. Our method has a spatial resolution almost same as that of the absorption contrast microscope image obtained by removing the grating. We demonstrate how our approach provides a phase image from experimentally obtained images. Our approach is attractive for easily appending a quantitative phase-sensitive mode to normal X-ray microscopes, and has potentially broad applications in biology and material sciences.
2010-06-23
Real time neutron radioscopy - trends and applications
International Nuclear Information System (INIS)
Real Time Radiography (RTR) finds extensive applications for inspection of objects on assembly lines for rapid inspection. A typical RTR widely used includes a image intensifier, CCD camera, image processor and high resolution TV monitor in addition to radiographic source. Image intensifiers used in X-radiography employ CsI as the input detector. With the increased use of neutrons as radiation source, real time neutron radiography is also being practised widely. Image intensifiers used in neutron radiography employ gadolinium as the input screen. The neutron image intensifier system at the authors laboratory essentially consists of a 9 inch Trifield image intensifier tube, motorised zoom lens, CCD camera and a high resolution TV monitor
2003-11-12
British Library Electronic Table of Contents (United Kingdom)
This paper introduces a parallel measurement approach for fast infrared-based human temperature screening suitable for use in a large public area. Our key idea is based on the combination of simple image processing algorithms, infrared technology, and human flow management. With this multidisciplinary concept, we arrange as many people as possible in a two-dimensional space in front of a thermal imaging camera and then highlight all human facial areas through simple image filtering, image morphological, and particle analysis processes. In this way, an individual's face in live thermal image can be located and the maximum facial skin temperature can be monitored and displayed. Our experiment shows a measured 1ms processing time in highlighting all human face areas. With a thermal imaging ca...
2009-01-01
Feasibility study of the iterative x-ray phase retrieval algorithm
International Nuclear Information System (INIS)
An iterative phase retrieval algorithm was previously investigated for in-line x-ray phase imaging. Through detailed theoretical analysis and computer simulations, we now discuss the limitations, robustness, and efficiency of the algorithm. The iterative algorithm was proved robust against imaging noise but sensitive to the variations of several system parameters. It is also efficient in terms of calculation time. It was shown that the algorithm can be applied to phase retrieval based on one phase-contrast image and one attenuation image, or two phase-contrast images; in both cases, the two images can be obtained either by one detector in two exposures, or by two detectors in only one exposure as in the dual-detector scheme.
2009-01-01
Digital radiography of pulmonary abnormalities using Fuji computed radiography (FCR)
Energy Technology Data Exchange (ETDEWEB)
Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were ...
1991-12-01
Digital radiography of pulmonary abnormalities using Fuji computed radiography (FCR)
International Nuclear Information System (INIS)
Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and ...
1991-01-01
Radiation doses in adults and children in standardized diagnostic radiology
International Nuclear Information System (INIS)
For comparison of radiation exposure and risk in different diagnostic procedures for adults and children dose measurements and calculations of organs with special risk were carried out. Parameters of image formation influencing image quality as well as of exposure concerning infants and children are recorded and discussed as to radiation exposure and protection. Conclusions are drawn with respect to systems of image formation and to standards of examination and quality assurance.
1987-01-01
Imaging Three Dimensional Two-Particle Correlations for Heavy-Ion Reaction Studies
Energy Technology Data Exchange (ETDEWEB)
The authors report an extension of the source imaging method for analyzing three-dimensional sources from three-dimensional correlations. The technique consists of expanding the correlation data and the underlying source function in spherical harmonics and inverting the resulting system of one-dimensional integral equations. With this strategy, they can image the source function quickly, even with the extremely large data sets common in three-dimensional analyses.
2005-06-27
Characterization of Adaptive Optics at Keck Observatory
Energy Technology Data Exchange (ETDEWEB)
In this paper, the adaptive optics (AO) system at Keck Observatory is characterized. The AO system is described in detail. The physical parameters of the lenslets, CCD and deformable mirror, the calibration procedures and the signal processing algorithms are explained. Results of sky performance tests are presented: the AO system is shown to deliver images with an average Strehl ratio of up to 0.37 at 1.59 {micro}m using a bright guide star. An error budget that is consistent with the observed image quality is presented.
2003-07-24
International Nuclear Information System (INIS)
Objective: To investigate the relationship between exposure dose and image quality for a direct digital radiography system and to determine the optimum exposure parameters for pelvic examination. Methods: A contrast-detail phantom CDRAD2.0 was exposed to different doses and the IQF of phantom images were calculated. The optimum exposure parameters were determined by ANOVA and SNK analysis. The image of an anthropomorphic phantom taken with optimized exposure parameters was verified using CEC image criteria. Results: The IQF of the images of CDRAD2.0 phantom was significantly different for different doses, as the exposure dose was greater than 0.61 mGy. The IQFs have no difference for different dose groups. The image quality between this optimized exposure dose and conventional exposure dose not was significantly different. Conclusion: The ...
2005-10-01
A look ahead: PET/MR versus PET/CT
Energy Technology Data Exchange (ETDEWEB)
Integration of positron emission tomography (PET) and magnetic resonance (MR) has become a topic of increasing interest to the imaging community over the past two years. In this text, the authors attempt to distinguish facts from fiction concerning such integrated systems. Analysis of existing information of combined imaging on existing brain PET/MR systems and imaging experience with PET-computed tomography (CT) is reviewed. Various types of system integration of PET and MR are discussed with completely independent systems on one hand and completely integrated systems with the possibility of simultaneous data acquisition on the other hand. Furthermore, it is discussed, what simultaneous data acquisition with nuclear imaging systems combined with MR or CT really means, as ...
2009-03-15
Energy Technology Data Exchange (ETDEWEB)
The computer aided coal structure construction system is proposed, and a computational construction example is presented. The coal structure construction engine of this system fabricates molecular structure by connecting fragments sequentially inputted through a user interface. The best structure candidate is determined using construction knowledge and partial energy evaluation every addition of one fragment, and this process is subsequently repeated. The structure evaluation engine analyzes the 3-D conformation candidate by molecular dynamics, and evaluates the conformation by determining the energy value of an optimum structure. As an example, this system was applied to construction of coal molecular structure based on the actual data of partial structure composed of 26 structures from 2l kinds of aromatic cluster structures, 27 bonds from 2 kinds of bridged bonds, and 16 groups ...
1996-10-28
Real-time neutron monitoring method using an imaging plate
Energy Technology Data Exchange (ETDEWEB)
A novel system for real-time radiation monitoring in reactor or accelerator facilities has been studied using an imaging plate. The authors made a feasibility study on a new neutron detection system using both photostimulated luminescence (PSL) and prompt luminescence (PL) generated in a neutron imaging plate (NIP) when the NIP is irradiated by neutrons. A readout system consisting of a semiconductor laser and a photomultiplier tube was fabricated for the purpose. It was confirmed that the system can measure both PSL and PL, where Am-Li was used as a neutron source. It may be possible to establish a new wide-range neutron monitoring system using the developed system as a PL mode normally, and as a PSL mode in case of intense neutron dose that cannot be measured in a PL mode because of saturation of the detection ...
1999-07-01
Real-time neutron monitoring method using an imaging plate
International Nuclear Information System (INIS)
A novel system for real-time radiation monitoring in reactor or accelerator facilities has been studied using an imaging plate. The authors made a feasibility study on a new neutron detection system using both photostimulated luminescence (PSL) and prompt luminescence (PL) generated in a neutron imaging plate (NIP) when the NIP is irradiated by neutrons. A readout system consisting of a semiconductor laser and a photomultiplier tube was fabricated for the purpose. It was confirmed that the system can measure both PSL and PL, where Am-Li was used as a neutron source. It may be possible to establish a new wide-range neutron monitoring system using the developed system as a PL mode normally, and as a PSL mode in case of intense neutron dose that cannot be measured in a PL mode because of saturation of the detection ...
1999-04-19
International Nuclear Information System (INIS)
A mathematical model of multichannel radiometric inspection system was developed, in which the measurement results are reproduced in the form of a half-tone image equivalent to the radiation image of the irradiated object. The model makes the following assumptions: the beam of radiation is fan-shaped; the object of inspection is scanned discretely; the focal spot of the source is rectangular; the apertures of the detector are round, and the detectors themselves are equidistant from the sources, aimed at it, and form a close-packed array; the signals from the detectors are processed according to a time scheme; and the measurement results are corrected in a computer for normalizing the gains of the channels of the system. The mathematical model can serve as the basis for developing a method of calculating the optimal parameters of a multichannel radiometric system with visualization ...
Energy Technology Data Exchange (ETDEWEB)
The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)
2004-04-15
Enhanced Reliability MEMS Deformable Mirrors for Space Imaging ...
Sep 3, 2010 ... These higher-quality deformable mirrors will enable diffraction-limited performance for many space-based optical systems such as space-based ...
International Nuclear Information System (INIS)
A real-time two-dimensional void fraction distribution measurement of gas-liquid two-phase flow was carried out by real-time neutron radiography and real-time image processing. The JRR-3M real-time thermal neutron radiography system and a Musashi dynamic image processing system were used. Image processing methods to calculate two-dimensional and cross-sectional void fraction distributions were proposed. The void fraction distribution was calculated by non-linear processing of the neutron radiography image and displayed by pseudo-color in real-time. A simple gas-liquid two-phase flow induced by injecting gas through needles at the bottom of water pool in a rectangular vessel was tested. (orig.).
1996-07-01
Three-Dimensional Wing Kinematics and Aerodynamic Characteristics of a Beetle in Free Flight
Detailed three dimensional wing kinematics and aerodynamic characteristics are experimentally presented for the free flight of a beetle, Allomyrina dichotoma, which has a pair of elytra (fore wings) and hind wings. The kinematic parameters of the wing motion, such as the wing tip trajectory, angle of attack, torsion angle, and camber deformation, are obtained from a 3D reconstruction technique that involves the use of two or three synchronized high-speed cameras to digitize various points marked on the wings. Our data show outstanding characteristics of wing deformation and flexibility in the free flight of the beetle. To find out the mechanism of aerodynamic force, the leading edge vortex (LEV) and trailing edge vortex (TEV) on both elytron and hind wing were observed by using smoke wire visualization and digital particle image velocimetry (DPIV) technique. Qualitative smoke lines in the region of the most intent vortex ...
2010-11-01
Iterative Dense Correspondence Correction Through Bundle Adjustment Feedback-Based Error Detection
Energy Technology Data Exchange (ETDEWEB)
A novel method to detect and correct inaccuracies in a set of unconstrained dense correspondences between two images is presented. Starting with a robust, general-purpose dense correspondence algorithm, an initial pose estimate and dense 3D scene reconstruction are obtained and bundle-adjusted. Reprojection errors are then computed for each correspondence pair, which is used as a metric to distinguish high and low-error correspondences. An affine neighborhood-based coarse-to-fine iterative search algorithm is then applied only on the high-error correspondences to correct their positions. Such an error detection and correction mechanism is novel for unconstrained dense correspondences, for example not obtained through epipolar geometry-based guided matching. Results indicate that correspondences in regions with issues such as occlusions, repetitive patterns and moving objects can be identified and corrected, such that a more ...
2009-11-23
4D experience on Girassol Field block 17, Angola
Energy Technology Data Exchange (ETDEWEB)
The Girassol field is located in Angolan deep water of Block 17 and consists of large vertically stacked turbidities complexes. The reservoir extends over approximately 200 km{sup 2} and water depth ranges between 1300 and 1400 meters. In that context High Resolution 3D seismic became the most valuable tool to describe and monitor the reservoir. The field development plan took into account, through re-injection of the gas into the reservoir, Total environmental policy imposing the recycling of production gas. Monitoring of this injection was the main reason to shoot the first High Resolution 4D extremely early in the life of field. Despite the complexity of interpretation due to complex fluid situation and pressure effect, the results went way beyond expectations as the 4D images are of very high quality. Data has also been used to update and refine the reservoir flow model as well as to help deciding on the location of ...
2004-07-01
Tolerance limits of X-ray image intensity
International Nuclear Information System (INIS)
Evaluation of the tolerance limits of X-ray image density accepted by the radiologist shows that for different kinds of examinations, deviations of more than 50% from optimal density lead to images which cannot be used diagnostically. Within this range diagnostic accuracy shows a distinct maximum and diminishes to the limits by 20%. These figures are related to differences in the intensifying factor of screens, sensitivity of films, sensitometric parameters of film processing as well as the doses employed with automatic exposure control devices, measured in clinical conditions. Maximum permissible tolerance limits of the whole imaging system and of its constituents are discussed using the Gaussian law of error addition. (author).
Cerebral angiography using Fuji computed radiography (FCR) system
International Nuclear Information System (INIS)
Eighty-seven subtraction images of FCR were compared with subtraction images of conventional angiography. Although FCR images with reduced exposure dose (25 % of regular dose) and with diluted contrast material (150 mgI/ml, 50 % of usual concentration) were slightly inferior to the images of conventional angiography, most clinically important vessels were adequately visualized. As FCR has wider dynamic range and higher contrast resolution than conventional angiography, FCR may take over conventional angiography. (author).
1985-01-01
Electrical biasing and voltage contrast imaging in a focused ion beam system
Energy Technology Data Exchange (ETDEWEB)
We present two new techniques that enhance conventional focused ion beam (FIB) system capabilities for integrated circuit (IC) analysis: in situ electrical biasing and voltage contrast imaging. We have used in situ electrical biasing to enable a number of advanced failure analysis applications including (1) real time evaluation of device electrical behavior during milling and deposition, (2) verification of IC functional modifications without removal from the FIB system, and (3) ultraprecision control for cross sectioning of deep submicron structures, such as programmed amorphous silicon antifuses. We have also developed FIB system voltage contrast imaging that can be used for a variety of failure analysis applications. The use of passive voltage contrast imaging for defect localization and for navigation on planarized devices will be illustrated. In addition, ...
1995-09-01
TECAB - Totally Endoscopic Coronary Artery Bypass
... CT angiograph for the peripheral rteries. a beautiful 3D-vision on the structures inside e chest. Okay. ... have an angled camera here. This is a 3D camera, and the surgeon has got th What ...
Users manual for CAFE-3D : a computational fluid dynamics fire code
International Nuclear Information System (INIS)
The Container Analysis Fire Environment (CAFE) computer code has been developed to model all relevant fire physics for predicting the thermal response of massive objects engulfed in large fires. It provides realistic fire thermal boundary conditions for use in design of radioactive material packages and in risk-based transportation studies. The CAFE code can be coupled to commercial finite-element codes such as MSC PATRAN/THERMAL and ANSYS. This coupled system of codes can be used to determine the internal thermal response of finite element models of packages to a range of fire environments. This document is a user manual describing how to use the three-dimensional version of CAFE, as well as a description of CAFE input and output parameters. Since this is a user manual, only a brief theoretical description of the equations and physical models is included.
2005-03-01
British Library Electronic Table of Contents (United Kingdom)
This article presents numerical study of 3-D thermosolutale mixed convection (TSMC) in horizontal rectangular channels. The contribution of this work is to characterize the travelling wave's appearance and to generalize the behavior of Poiseuille-Rayleigh-Benard (PRB) systems for a broad range of dimensionless parameters, which control the double diffusive mixed convection. The numerical results consist of analyzing the flow regimes of the steady longitudinal thermoconvectives rolls for the case of purely thermal mixed convection (TMC) and for both thermal and mass transfer (TSMC). The transition from opposed volume forces to cooperating ones at fixed Rayleigh (Ra), Reynolds (Re), and Lewis (Le) numbers, considerably affects the birth and the development of the longitudinal rolls (noted R/...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
This study presents new software, called Google Earth-based Optimal HAulage RouTing System (GEOHARTS), to improve the functionality of Google Earth for optimal haulage routing of off-road dump trucks in construction and mining sites. A modified least-cost path algorithm, which is applicable to working areas with both paved and unpaved temporary roads and can consider the effects of terrain relief and curves along a route on the route planning, was proposed and utilized for the software development. GEOHARTS can determine optimal haulage routes between loaders and dumps that ensure the least travel time or fuel consumption of off-road dump trucks and can visualize the results using an embedded 3D render window of Google Earth. The application to the Pasir open-pit coal mine in Indonesia dem...
2011-01-01
Measurements of K-beta/K-alpha X-ray intensity ratios using VEC beams
International Nuclear Information System (INIS)
An experiment on the K#beta#/K#alpha# characteristic X-ray intensity ratio in silver was performed at VEC Centre, Calcutta using the #alpha#-beams at energies 40 MeV and 50 MeV employing a Si(Li) detector system on-line. The results show that the K#beta#/K#alpha# X-ray intensity ratio at energies 40 and 50 MeV are 0.215 #+-# 0.006 and 0.216 #+-# 0.006, respectively, which indicates no change with beam energy and in accordance with the earlier reports. The present experiment shows the feasibility of studying the K#beta#/K#alpha# ratios as a function of beam energy in different regions of periodic table. Experiments in elements belonging to the 3d shell and their compounds are suggested to look for the chemical effects and their dependence on #alpha#-energy. (author). 7 refs.
1987-02-03
British Library Electronic Table of Contents (United Kingdom)
The ground state of a three-dimensional (3D) rotating trapped superfluid Fermi gas in the BCS-BEC crossover is mapped to finite N v -body vortex states by a simple ansatz. The total vortex energy is measured from the ground-state energy of the system in the absence of the vortices. The vortex state is stable since the vortex potential and rotation energies are attractive while the vortex kinetic energy and interaction between vortices are repulsive. By combining the analytical and numerical works for the minimal vortex energy, the 2D configurations of N v vortices are studied by taking into account of the finite size effects both on xy-plane and on z-direction. The calculated vortex numbers as a function of the interaction strength are appropriate to the renew experimental results by Zwier...
2011-01-01
Development of Seismic Analysis Model and Time History Analysis for KALIMER-600
Energy Technology Data Exchange (ETDEWEB)
This report describes a simple seismic analysis model of the KALIMER-600 sodium cooled fast reactor and its application to the seismic time history analysis. To develop the simple seismic analysis model, the detailed 3-D finite element analyses for main components, IHTS piping system, and reactor building were carried out to verify the dynamic characteristics of each part of simple seismic analysis models. By using the developed simple model, the seismic time history analyses for both cases of a seismic isolation and non-isolation design of KALIMER-600 were performed. From the comparison of the calculated floor response spectrum, it is verified that the seismically isolated KALIMER-600 reactor building shows a great performance of a seismic isolation and assures a seismic integrity.
2007-02-15
Cloud Formation and Dynamics in Cool Dwarf and Hot Exoplanetary Atmospheres
The lowest-mass stars, brown dwarfs and extrasolar planets present challenges and opportunities for understanding dynamics and cloud formation processes in low-temperature atmospheres. For brown dwarfs, the formation, variation and rapid depletion of photospheric clouds in L- and T-type dwarfs, and spectroscopic evidence for non-equilibrium chemistry associated with vertical mixing, all point to a fundamental role for dynamics in vertical abundance distributions and cloud/grain formation cycles. For exoplanets, azimuthal heat variations and the detection of stratospheric and exospheric layers indicate multi-layered, asymmetric atmospheres that may also be time-variable (particularly for systems with highly elliptical orbits). Dust and clouds may also play an important role in the thermal energy balance of exoplanets through albedo effects. For all of these cases, 3D atmosphere models are becoming an increasingly essential ...
2009-01-01
Body-and-cad Geometric Constraint Systems
Motivated by constraint-based CAD software, we develop the foundation for the rigidity theory of a very general model: the body-and-cad structure, composed of rigid bodies in 3D constrained by pairwise coincidence, angular and distance constraints. We identify 21 relevant geometric constraints and develop the corresponding infinitesimal rigidity theory for these structures. The classical body-and-bar rigidity model can be viewed as a body-and-cad structure that uses only one constraint from this new class. As a consequence, we identify a new, necessary, but not sufficient, counting condition for minimal rigidity of body-and-cad structures: nested sparsity. This is a slight generalization of the well-known sparsity condition of Maxwell.
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
The solution of the governing steady transport equations for momentum, heat and mass transfer in flowing fluids can be very difficult. These difficulties arise from the nonlinear, coupled, nonsymmetric nature of the system of algebraic equations that results from spatial discretization of the PDEs. In this manuscript the authors focus on evaluating a proposed nonlinear solution method based on an inexact Newton method with backtracking. In this context they use a particular spatial discretization based on a pressure stabilized Petrov-Galerkin finite element formulation of the low Mach number Navier-Stokes equations with heat and mass transport. The discussion considers computational efficiency, robustness and some implementation issues related to the proposed nonlinear solution scheme. Computational results are presented for several challenging CFD benchmark problems as well as two large scale 3D flow simulations.
1997-02-01
Energy Technology Data Exchange (ETDEWEB)
Parallel imaging and echo sharing techniques have markedly reduced the acquisition times for MRI of large volumes. Dynamic 2 and 3-dimensional data sets of the chest with high temporal resolution (up to 10 images/s with single slice and 2 volume/s) allow an analysis of respiratory motion of the lungs and tumors. Time-resolved 2D series in preselected planes can be used to observe respiratory motion during free breathing or after respiratory commands, e.g. to exclude chest wall invasion by a tumor or for diagnosing impairment of respiratory mechanics. Time-resolved 3D-series (4D-MRI) allow monitoring of the spatial displacement of the lungs and tumors as a whole volume. Present limitations such as an overestimation of tumor size and an underestimation of displacement due to a limited temporal resolution are expected to be overcome with further technical developments. However, 4D-MRI already appears to be ...
2009-08-15
... Exercises: Day and Night Classroom Exercises: Pinhole Focusing 3D Vision and Eye Health < Contact Lenses Monovision Playlist: ...
Debris Dispersion Model Using Java 3D
This paper describes web based simulation of Shuttle launch operations and debris dispersion. Java
2004-01-01
... Exercises: Day and Night Classroom Exercises: Pinhole Focusing 3D Vision and Eye Health < Caring for Your Vision ...
Direct digital radiography vs conventional radiography of thoracic spine: a comparative study
International Nuclear Information System (INIS)
Objective: An evaluation of the application of DR in thoracic spine and a comparative study of the DR with the conventional radiography. Methods: DR images and the conventional radiogram of 89 cases respectively were evaluated by 3 vice-consultant doctors and 2 chief technicians. Statistics was processed with 2 categories: (1) images were classified into grade A, B, C and condemned according to the image quality; and (2) thoracic spine are divided into upper, middle and lower portions, in which the rate of successful imaging were compared respectively. Results: The image quality of DR: 74. 1% images in grade A, 20.2% in grade B, 5.7% in grade C, and no image condemned. Conventional radiogram: 45% images in grade A, 41.6% in grade B, 11.2% in grade C, and 2.2% images condemned. The successful ...
2005-09-01
The mixture of 1,3-dichloropropene (1,3-D) and chloropicrin (CP) is used as a preplant soil fumigant. In comparison with individual fumigants, application of a mixture may affect the environmental dissipation and fate of each chemical, such as emission and degradation. We investigated the degradation of CP, 1,3-D, and their mixture in fresh soils and sterile soils, and evaluated the competitive characteristic of fumigants in the mixture. The degradation of low concentrations of CP in fresh soil was accelerated at early times in the presence of 1,3-D, whereas the addition of CP reduced the degradation rate of trans-1,3-D, possibly by inhibiting the activity of trans-1,3-D degrading microorganisms. The potential of applying amendments to the soil to increase the rate of CP and ...
Calculated valence electronic structure of 3d metals for use in the X-ray intensity ratio studies
Energy Technology Data Exchange (ETDEWEB)
3d occupation numbers of the transition elements corresponding to various types of atomic configurations are calculated by means of the linear muffin-tin orbital (LMTO) method. This data is used with the multiconfiguration Dirac-Fock (MCDF) X-ray intensity ratios to estimate the electron populations of the 3d metals in alloys.
2010-09-15
Calculated valence electronic structure of 3d metals for use in the X-ray intensity ratio studies
International Nuclear Information System (INIS)
3d occupation numbers of the transition elements corresponding to various types of atomic configurations are calculated by means of the linear muffin-tin orbital (LMTO) method. This data is used with the multiconfiguration Dirac-Fock (MCDF) X-ray intensity ratios to estimate the electron populations of the 3d metals in alloys.
2010-09-01
Energy Technology Data Exchange (ETDEWEB)
As the jump from 2D to 3D, seismic exploration lives a new revolution with the use of converted PS waves. Indeed PS converted waves are proving their potential as a tool for imaging through gas; lithology discrimination; structural confirmation; and more. Nevertheless, processing converted shear data and in particular determining accurate P and S velocity models for depth imaging of these data is still a challenging problem, especially when the subsurface is anisotropic. To solve this velocity model determination problem we propose to use reflection travel time tomography. In a first step, we derive a new approximation of the exact phase velocity equation of the SV wave in anisotropic (TI) media. This new approximation is valid for non-weak anisotropy and is mathematically simpler to handle than the exact equation. Then, starting from an isotropic reflection tomography tool developed at Lt-'P, ...
2001-12-01
Energy Technology Data Exchange (ETDEWEB)
Purpose. We have tested a procedure of focal injection of the contrast medium Lipiodol as a fiducial marker for image-guided boost of the tumor in bladder cancer radiotherapy (RT). In this study, we have evaluated the feasibility and the safety of the method as well as the inter- and intra-fraction shift of the bladder tumor. Materials and methods. Five patients with muscle invasive urinary bladder cancer were included in the study. Lipiodol was injected during flexible cystoscopy into the submucosa of the bladder wall at the periphery of the tumor or the post resection tumor-bed. Cone-beam CT (CBCT) scans were acquired daily throughout the course of RT. Results. Lipiodol demarcation of the bladder tumor was feasible and safe with only a minimum of side effects related to the procedure. The Lipiodol spots were visible on CT and CBCT scans for the duration of the RT course. More than half of all the treatment fractions required a geometric shift of 5 mm or more to ...
2010-10-15
A High-Frequency Secondary Event During the 2004 M6.0 Parkfield Earthquake
We present an image of the rupture propagation of the 2004 M6.0 Parkfield earthquake using records from a dense network of local strong motion stations. We back-propagate high-frequency waveforms in 3D with a method, similar to reverse time migration, to obtain an estimate of the distribution of radiated high-frequency seismic energy in space and time. The image is forced to be coherent at the known hypocenter location and the quake origin time by applying small static time shifts obtained using waveform cross-correlation. We observe that the Parkfield earthquake radiated a distinct secondary high-frequency phase, which is located about 12.5~km northwest of the hypocenter with an onset of seismic radiation about 5~s after the rupture initiation. The time history of the back-projection suggests a rupture velocity of 2.5~km/s between hypocenter and subevent. The back-projection result is confirmed by ...
2007-12-01
Energy Technology Data Exchange (ETDEWEB)
A computer controlled digital system, Fuji Computed Radiography (FCR) is capable of providing more stable output image than conventional screen/film system. So FCR would be an ideal system for the detection of pneumoconiosis due to the constant high quality of the output films. We tried to find the optimum image processing to compensate the small size (1/2 in length of a full-size radiograph) of the output image of digital radiography. The best result for FCR was given with gamma 0.85 and 0.30 enhancement of response at spatial frequency of 0.085 cycle/mm. On the other hand, the digitally processed FCR size ILO standard films, the characteristics of which is different from FCR output films, proved to be most preferable when the image processing is made with gamma 0.85 and 0.25 enhancement at spacial frequency of 0.17 cycle/mm. If the above ...
1993-06-01
We present a femtosecond Laser Two-Photon Polymerization (LTPP) system of large scale three-dimensional structuring for applications in tissue engineering. The direct laser writing system enables fabrication of artificial polymeric scaffolds over a large area (up to cm in lateral size) with sub-micrometer resolution which could find practical applications in biomedicine and surgery. Yb:KGW femtosecond laser oscillator (Pharos, Light Conversion. Co. Ltd.) is used as an irradiation source (75 fs, 515 nm (frequency doubled), 80 MHz). The sample is mounted on wide range linear motor driven stages having 10 nm sample positioning resolution (XY--ALS130-100, Z--ALS130-50, Aerotech, Inc.). These stages guarantee an overall travelling range of 100 mm into X and Y directions and 50 mm in Z direction and support the linear scanning speed up to 300 mm/s. By moving the sample three-dimensionally the position of laser focus in the photopolymer is changed and ...
2010-11-10
Validity of the CT to attenuation coefficient map conversion methods
International Nuclear Information System (INIS)
The most important commercialized methods of attenuation correction in SPECT are based on attenuation coefficient map from a transmission imaging method. The transmission imaging system can be the linear source of radioelement or a X-ray CT system. The image of transmission imaging system is not useful unless to replacement of the attenuation coefficient or CT number with the attenuation coefficient in SPECT energy. In this paper we essay to evaluate the validity and estimate the error of the most used method of this transformation. The final result shows that the methods which use a linear or multi-linear curve accept a error in their estimation. The value of mA is not important but the patient thickness is very important and it can introduce a error more than 10 percent in the final result.
2004-04-27
ISR; A database for symbolic processing in computer vision
Energy Technology Data Exchange (ETDEWEB)
Computer vision imposes unique requirements on the representation and manipulation of image data and knowledge. At a vision system's lowest level are sensors that represent an image with purely numeric image arrays, while at the highest level are semantic world models that provide the final interpretation of the scene. In between are thousands of intermediate descriptions, many of which must be repeatedly accessed and processed during interpretation. In this article, the authors describe a representation and management system for use at the intermediate (symbolic) level of vision. Based on database management methodology, the intermediate symbolic representation (ISR) mediates access to intermediate-level vision data and forms an active interface to the higher-level inference processes that construct an image's interpretation. The ...
1989-12-01
Energy Technology Data Exchange (ETDEWEB)
Existing oil reservoirs might be more fully exploited if the properties of the flow of oil and water in porous media were better known. In laboratory experiments it is important to collect as much information as possible to make a descriptive model of the system, including position imaging and chemical binding information. This thesis develops nuclear methods for obtaining position image and chemical binding information from flow experiments of porous media. A combined positron emission tomography and single photon emission computed tomography system to obtain position images, and a time-differential perturbed angular correlation system to obtain chemical binding information, have been built and thoroughly tested. 68 refs., 123 figs., 14 tabs.
1998-12-01
Evaluation of the chest radiography using Fuji computed radiography (FCR) system
International Nuclear Information System (INIS)
Chest radiograms obtained by using Fuji Computed Radiography (FCR) system were compared to conventional film/screen radiograms. The FCR images showed better image quality in diagnostic information than the conventional chest images. In FCR, the radiation exposure to patient for chest examination could be reduced up to one tenths of conventional chest examination. The main advantages or FCR were considered to depend on the contrast processing and frequency processing properties. The use of FCR in clinical work may improve both diagnostic quality and radiation exposure.
1991-12-01
Confocal Imaging of Biological Tissues Using Second Harmonic Generation
Energy Technology Data Exchange (ETDEWEB)
A confocal microscopy imaging system was devised to selectively detect Second harmonic signals generated by biological tissues. Several types of biological tissues were examined using this imaging system, including human teeth, bovine blood vessels, and chicken skin. All these tissues generated strong second harmonic signals. There is considerable evidence that the source of these signals in tissue is collagen. Collagen, the predominant component of most tissues, is known to have second order nonlinear susceptibility. This technique may have diagnostic usefulness in pathophysiological conditions characterized by changes in collagen structure including malignant transformation of nevi, progression of diabetic complications, and abnormalities in wound healing.
2000-03-06
Clinical magnetic resonance imaging with nuclear medicine correlation
Energy Technology Data Exchange (ETDEWEB)
The current role of magnetic resonance imaging (MRI) in different organ systems is discussed and compared to nuclear medicine and to other available clinical diagnostic modalities. The value of optimizing radiofrequency pulse sequence selection to provide additional tissue characterization is also described. The results of nuclear medicine and MRI studies in 56 patients are compared to evaluate the clinical diagnostic contribution of each imaging modality for various pathological processes. In addition, the state-of-the-art MRI systems and future development in MRI technology with its potential contribution is defined.
1985-08-01
Technical note: A physical phantom for assessment of accuracy of deformable alignment algorithms
International Nuclear Information System (INIS)
The purpose of this study was to investigate the feasibility of a simple deformable phantom as a QA tool for testing and validation of deformable image registration algorithms. A diagnostic thoracic imaging phantom with a deformable foam insert was used in this study. Small plastic markers were distributed through the foam to create a lattice with a measurable deformation as the ground truth data for all comparisons. The foam was compressed in the superior-inferior direction using a one-dimensional drive stage pushing a flat 'diaphragm' to create deformations similar to those from inhale and exhale states. Images were acquired at different compressions of the foam and the location of every marker was manually identified on each image volume to establish a known deformation field with a known accuracy. The markers were removed digitally from corresponding images prior to ...
2007-07-01
Single exposure energy subtraction chest radiography in the diagnosis of pulmonary cancer
Energy Technology Data Exchange (ETDEWEB)
A single exposure energy subtraction technique with a metal filter and an imaging plate for the Fuji Computed Radiography (FCR) system was developed for dual-energy subtraction radiography (DES) of the chest. By the use of this technique, 206 patients with suspected lung cancer were scanned in the clinical settings. The subtracted images in 200 patients, excluding six with poor image quality, were examined. Soft-tissue images (bone cancelled images) were useful in visualizing abnormality of the airway and nodules lying under the ribs; and bone images (soft-tissue cancelled images) in detecting rib metastases and the presence or absence of calcification in nodules. Additional information was acquired in 21 % (42/200). A single exposure is capable of neglecting motion artifacts. In addition, this technique may be of value ...
1987-03-01
Single exposure energy subtraction chest radiography in the diagnosis of pulmonary cancer
International Nuclear Information System (INIS)
A single exposure energy subtraction technique with a metal filter and an imaging plate for the Fuji Computed Radiography (FCR) system was developed for dual-energy subtraction radiography (DES) of the chest. By the use of this technique, 206 patients with suspected lung cancer were scanned in the clinical settings. The subtracted images in 200 patients, excluding six with poor image quality, were examined. Soft-tissue images (bone cancelled images) were useful in visualizing abnormality of the airway and nodules lying under the ribs; and bone images (soft-tissue cancelled images) in detecting rib metastases and the presence or absence of calcification in nodules. Additional information was acquired in 21 % (42/200). A single exposure is capable of neglecting motion artifacts. In addition, this technique may be of value ...
1987-01-01
Energy Technology Data Exchange (ETDEWEB)
Forests on the Kola Peninsula in Northern Russia grow close to the northern tree line. They are subjected to both natural and anthropogenic stress factors. The Cu-Ni smelter 'Severonikel' (Lat. 67 deg 55'N; Long. 32 deg 57'E) near Monchegorsk is one of the two major sources of sulphur dioxide and heavy metals emissions on the Kola Peninsula. These emissions have caused significant deterioration of the surrounding vegetation. The thesis demonstrates how methods of Remote sensing, ground survey and mathematical modelling can be integrated for monitoring of the smelter's environmental impact on the surrounding vegetation: ground truth data are used for calibration of remote-sensed data, which further serve to verify mathematical models. The study aims were: * to estimate the scale of airborne sulphur pollution from the smelting industry on the Kola Peninsula and its effect on vegetation; * to assess spatial extent of the forest decline in the ...
1998-07-01
TART97. A Coupled Neutron-Photon 3-D Combinatorial Geometry Monte Carlo Transport Code
TART97 is a coupled neutron-photon, 3 dimensional, combinatorial geometry, time dependent Monte Carlo transport code. This code can run on any modern computer. It is a complete system to assist you with input preparation, running Monte Carlo calculations, and analysis of output results. TART97 is also incredibly fast: if you have used similar codes, you will be amazed at how fast this code is compared to other similar codes. Use of the entire system can save you a great deal of time and energy. TART 97 is distributed on CD. This CD contains on-line documentation for all codes included in the system, the codes configured to run on a variety of computers, and many example problems that you can use to familiarize yourself with the system. TART97 completely supersedes all older versions of TART, and it is strongly recommended that users only use the most recent version of TART97 and ist data files.
1997-11-22
Proving Stabilization of Biological Systems
We describe an efficient procedure for proving stabilization of biological systems modeled as qualitative networks or genetic regulatory networks. For scalability, our procedure uses modular proof techniques, where state-space exploration is applied only locally to small pieces of the system rather than the entire system as a whole. Our procedure exploits the observation that, in practice, the form of modular proofs can be restricted to a very limited set. For completeness, our technique falls back on a non-compositional counterexample search. Using our new procedure, we have solved a number of challenging published examples, including: a 3-D model of the mammalian epidermis; a model of metabolic networks operating in type-2 diabetes; a model of fate determination of vulval precursor cells in the C. elegans worm; and a model of pair-rule regulation during segmentation in the ...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Ejector refrigeration systems are usually designed to utilize low grade energy for driving the cycle. They also have low maintenance cost because they operate without a compressor. Mainly, the ejector performance directly affects the refrigerating performance. Therefore, an investigation on the characteristics and an efficient design of the ejector are important to improve ejector refrigeration systems. In this study, the computational fluid dynamics (CFD) code, FLUENT, is employed to predict the flow phenomena and performance of CPM and CMA steam ejectors. The ejector refrigeration system, using water as the working fluid, is operated at 120-140 C boiler temperature and 5-15 C evaporator temperature. CFD can predict ejector performance very well and reveal the effect of operating conditions on an effective area that is directly related to its performance. Besides, it is found that the flow pattern does not depend much on ...
2007-09-15
Energy Technology Data Exchange (ETDEWEB)
Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided into four parts and ...
1989-08-01
Screen-film-combinations for radiography - present and future spectrum of application
Energy Technology Data Exchange (ETDEWEB)
From the numbers of radiographs of the different examinations and the total amount of radiological diagnostics in the GDR their possible modification by new imaging techniques is discussed under the aspects of costs and radiation burden. Film-screen-systems are of special importance, because they also will be most frequently used image recording system in future. The importance of their various properties and parameters, methods of determining these parameters as well as future developments are analyzed from the standpoint of practical requirements.
1985-01-01
Screen-film-combinations for radiography - present and future spectrum of application
International Nuclear Information System (INIS)
From the numbers of radiographs of the different examinations and the total amount of radiological diagnostics in the GDR their possible modification by new imaging techniques is discussed under the aspects of costs and radiation burden. Film-screen-systems are of special importance, because they also will be most frequently used image recording system in future. The importance of their various properties and parameters, methods of determining these parameters as well as future developments are analyzed from the standpoint of practical requirements. (author).
Tolerancing of assembly mechanisms is a major interest in the product life cycle. One can distinguish several models with growing complexity, from 1-dimensional (1D) to 3-dimensional (3D) (including form deviations), and two main tolerancing assumptions, the worst case and the statistical hypothesis. This paper presents an approach to 3D statistical tolerancing using a new acceptance criterion. Our approach is based on the 1D inertial acceptance criterion that is extended to 3D and form acceptance. The modal characterisation is used to describe the form deviation of a geometry as the combination of elementary deviations (location, orientation and form). The proposed 3D statistical tolerancing is applied on a simple mechanism with lever arm. It is also compared to the traditional worst-case tolerancing using a tolerance ...
2010-01-01
3-D depth migration via McClellan transformations
Energy Technology Data Exchange (ETDEWEB)
Three-dimensional seismic wavefields may be extrapolated in depth, one frequency at a time, by two-dimensional convolution with a circularly symmetric, frequency- and velocity-dependent filter. This depth extrapolation, performed for each frequency independently, lies at the heart of 3-D finite-difference depth migration. The computational efficiency of 3-D depth migration depends directly on the efficiency of this depth extrapolation. McClellan transformations provide an efficient method for both designing and implementing two-dimensional digital filters that have a particular form of symmetry, such as the circularly symmetric depth extrapolation filters used in 3-D depth migration. Given the coefficients of one-dimensional, frequency- and velocity-dependent filters used to accomplish 2-D depth migration, McClellan transformations lead to a simple and efficient ...
1990-01-01
Photoacoustic imaging using an ultrasonic Fresnel zone plate transducer
International Nuclear Information System (INIS)
A photoacoustic (PA) imaging system based on an ultrasonic Fresnel zone plate (FZP) transducer is developed for the purpose of imaging biological tissue. This FZP transducer has a two-zone negative zone plate piezoelectric material pattern, and an optical fibre is integrated with the transducer on the symmetric axis of the zone plates to deliver laser pulses to the sample. The focal characteristic of the FZP transducer is analysed by theoretical prediction and experimental measurement, and the measured results are in good agreement with the predicted results. The limited-field back-projection deconvolution algorithm combined with the coherence-factor weighting technique is used to reconstruct the optical absorption distribution. The experiments were performed with phantoms and the blood vessels of chicken embryo chorioallantoic membrane. The results demonstrate that PA imaging using the FZP transducer ...
2008-05-07
PET and MRI in cardiac imaging: from validation studies to integrated applications
International Nuclear Information System (INIS)
Positron emission tomography (PET) is the gold standard for non-invasive assessment of myocardial viability and allows accurate detection of coronary artery disease by assessment of myocardial perfusion. Magnetic resonance imaging (MRI) provides high resolution anatomical images that allow accurate evaluation of ventricular structure and function together with detection of myocardial infarction. Potential hybrid PET/MR tomography may potentially facilitate the combination of information from these imaging modalities in cardiology. Furthermore, the combination of anatomical MRI images with the high sensitivity of PET for detecting molecular targets may extent the application of these modalities to the characterization of atherosclerotic plaques and to the evaluation of angiogenetic or stem cell therapies, for example. This article reviews studies using MRI and PET in parallel to compare their performance ...
2009-03-01
Fundamental concepts of digital image processing
The field of a digital-image processing has experienced dramatic growth and increasingly widespread applicability in recent years. Fortunately, advances in computer technology have kept pace with the rapid growth in volume of image data in these and other applications. Digital image processing has become economical in many fields of research and in industrial and military applications. While each application has requirements unique from the others, all are concerned with faster, cheaper, more accurate, and more extensive computation. The trend is toward real-time and interactive operations, where the user of the system obtains preliminary results within a short enough time that the next decision can be made by the human processor without loss of concentration on the task at hand. An example of this is the obtaining of two-dimensional (2-D) computer-aided tomography (CAT) images. A ...
1983-03-01
Camera position estimation and feature extraction from an incomplete image of a landmark
British Library Electronic Table of Contents (United Kingdom)
In the autonomous unmanned helicopter landing problem, the position of the unmanned helicopter relative to the landmark is very important. A camera carried on the unmanned helicopter can capture an image of the landmark. In earlier research, it was reported that the camera position could be estimated by features extracted from the landmark image. However, it is necessary that the landmark image should be complete, or with only slight deficiencies, in order for this estimation process to be possible. In this article, we report on an innovative design for an estimation made from a camera position giving an incomplete single image of the landmark. An adaptive neuro-fuzzy inference system (ANFIS) is used to construct the mapping relation between the features of complete and incomplete landmark...
2011-01-01
Electromagnetic tracking in the clinical environment
UK PubMed Central (United Kingdom)
When choosing an electromagnetic tracking system (EMTS) for image-guided procedures several factors must be taken into consideration. Among others these include the system’s refresh rate, the...Full Text Available
2009-03-01
UK PubMed Central (United Kingdom)
Objective. For the multislice CT (MSCT) systems with a larger number of detector rows, it is essential to employ dose-reduction techniques. As...Full Text Available
2008-01-01
Colour television, an imitation of the human visual system.
UK PubMed Central (United Kingdom)
Colour television is examined as an attempt to imitate the human visual system in image formation, spectral sensitivities, adaptation, contrast effects, signal processing, signal modulation, signal...Full Text Available
1975-07-01
Classification of hematologic malignancies using texton signatures
UK PubMed Central (United Kingdom)
We describe a decision support system to distinguish among hematology cases directly from microscopic specimens. The system uses an image database containing digitized specimens from normal...Full Text Available
2007-10-01
Energy Technology Data Exchange (ETDEWEB)
The long-term aim of our research is to develop humidification-dehumidification desalination technology for farms in arid coastal regions that are suffering from salt-infected soils and shortages of potable groundwater. The specific aim of our current study was to determine the influence of greenhouse-related parameters on a process, called Seawater Greenhouse, which combines fresh water production with growth of crops in a greenhouse system. A thermodynamic model was used based on heat and mass balances. The dimension of the greenhouse had the greatest overall effect on the water production and energy consumption. A wide shallow greenhouse, 200 m wide by 50 m deep gave 125 m{sup 3} d{sup -1} of fresh water. This was greater than a factor of two compared to the worst-case scenario with the same area (50 m wide by 200 m deep), which gave 58 m{sup 3} d{sup -1}. Low power consumption ...
2003-11-01
Heterogeneous gasless reactive systems, including high-energy density metal-nonmetal compositions, have seen increasing study due to their various applications. However, owing to their high reaction temperature, short reaction time, and small scale of heterogeneity, investigation of their reaction mechanisms and kinetics is very difficult. In this study, microstructural changes and the kinetics of product layer growth in the W-Si system was investigated using a high-speed x-ray phase-contrast imaging technique. Using the Advanced Photon Source of Argonne National Laboratory, this method allowed direct imaging of irreversible reactions in the W-Si reactive system at frame rates up to 36 000 frames per second with 4 {mu}s exposure and spatial resolution of 10 {mu}m. Details of the Si melt and reactions between W and Si, that are unable to be viewed with visible-light ...
2009-12-01
International Nuclear Information System (INIS)
Heterogeneous gasless reactive systems, including high-energy density metal-nonmetal compositions, have seen increasing study due to their various applications. However, owing to their high reaction temperature, short reaction time, and small scale of heterogeneity, investigation of their reaction mechanisms and kinetics is very difficult. In this study, microstructural changes and the kinetics of product layer growth in the W-Si system was investigated using a high-speed x-ray phase-contrast imaging technique. Using the Advanced Photon Source of Argonne National Laboratory, this method allowed direct imaging of irreversible reactions in the W-Si reactive system at frame rates up to 36 000 frames per second with 4 #mu#s exposure and spatial resolution of 10 #mu#m. Details of the Si melt and reactions between W and Si, that are unable to be viewed with visible-light ...
2009-12-01
FCR (Fuji Computed Radiography) in neurosurgery
Energy Technology Data Exchange (ETDEWEB)
As part of the evolution of computer technology, Fuji Computed Radiography (FCR) has been developed as a new system for radiographical diagnosis. In this system, the X-ray energy is stored on the imaging plate and then converted into digital signals utilizing scanning laser-stimulated luminence. After proper image processing, it offers much more improved information for diagnosis than the conventional film system does. Since April, 1986, we have principally used FCR (System 101) for neurosurgical practice. In this article, we present our recent experience and evaluate its usefulness.
1988-08-01
FCR (Fuji Computed Radiography) in neurosurgery
International Nuclear Information System (INIS)
As part of the evolution of computer technology, Fuji Computed Radiography (FCR) has been developed as a new system for radiographical diagnosis. In this system, the X-ray energy is stored on the imaging plate and then converted into digital signals utilizing scanning laser-stimulated luminence. After proper image processing, it offers much more improved information for diagnosis than the conventional film system does. Since April, 1986, we have principally used FCR (System 101) for neurosurgical practice. In this article, we present our recent experience and evaluate its usefulness. (author).
1988-01-01
Motion analysis of parallelly connected FPSO unit and LNG carrier
Energy Technology Data Exchange (ETDEWEB)
Nowadays, the floating production, storage, and offloading (FPSO) units are used to marginal oil fields and deep seas, because of mobility and reduced lead time from discovery to first production. One of the methods for offloading is to moor a tanker alongside the FPSO unit. In this case motion response of the system becomes highly complex, and will be affected by many factors such as hydrodynamic interaction and mechanical connections between the vessels. In this study, a quite general method is developed which has taken into account the hydrodynamic interaction as well as the effects of connectors and mooring lines, in motion response analysis of a multi-body floating system. For this purpose, 3-D source distribution method is applied for hydrodynamic analysis, and linear stiffness matrices are introduced to represent the effect of connectors and mooring lines on the motion equations. The method has ...
1996-12-31
Spray, combustion, and heat transfer studies in a Ricardo hydra direct-injection diesel engine
Energy Technology Data Exchange (ETDEWEB)
The spray and combustion development in a single-cylinder, direct-injection diesel engine equipped with optical access was examined using a number of complementary techniques. A laser imaging system, based around a pulsed copper-vapour laser synchronised to an intensified CCD camera, was used to obtain images of the four fuel sprays prior to combustion, and to determine the tip penetration of each spray as a function of crankangle. The surface heat flux to the wall of the piston bowl was measured by placing a fast-response thermocouple at the impingement point of one of the sprays, and a two-colour imaging system was used to obtain digital images of the flame temperature and equivalent soot distribution in the cylinder. (author)
1996-12-31
Groundtruth approach to accurate quantitation of fluorescence microarrays
Energy Technology Data Exchange (ETDEWEB)
To more accurately measure fluorescent signals from microarrays, we calibrated our acquisition and analysis systems by using groundtruth samples comprised of known quantities of red and green gene-specific DNA probes hybridized to cDNA targets. We imaged the slides with a full-field, white light CCD imager and analyzed them with our custom analysis software. Here we compare, for multiple genes, results obtained with and without preprocessing (alignment, color crosstalk compensation, dark field subtraction, and integration time). We also evaluate the accuracy of various image processing and analysis techniques (background subtraction, segmentation, quantitation and normalization). This methodology calibrates and validates our system for accurate quantitative measurement of microarrays. Specifically, we show that preprocessing the images produces results ...
2000-12-01
Energy Technology Data Exchange (ETDEWEB)
The clinical feasibility of using interventional examination techniques was tested with an equipment combining fluoroscopy and MR imaging. This hybrid system showed to be of advantage in a great number of interventional examinations. The 1.5 Tesla magnet proved to be superior to open MR scanning systems in terms of image quality and scanning times. (orig.) [Deutsch] Es wurde die klinische Durchfuehrbarkeit interventioneller Techniken an einem kombinierten Durchleuchtungs- und MR-Arbeitsplatz untersucht. Dieses Hybridsystem erwies sich bei einer Vielzahl interventioneller Eingriffe als vorteilhaft. Der 1,5 Tesla-Magnet ist offenen MR-Systemen hinsichtlich Bildqualitaet und Messzeit ueberlegen. (orig.)
1997-05-01
The application of the Fuji Computed Radiography system for the diagnosis of pneumoconiosis
International Nuclear Information System (INIS)
A computer controlled digital system, Fuji Computed Radiography (FCR) is capable of providing more stable output image than conventional screen/film system. So FCR would be an ideal system for the detection of pneumoconiosis due to the constant high quality of the output films. We tried to find the optimum image processing to compensate the small size (1/2 in length of a full-size radiograph) of the output image of digital radiography. The best result for FCR was given with gamma 0.85 and 0.30 enhancement of response at spatial frequency of 0.085 cycle/mm. On the other hand, the digitally processed FCR size ILO standard films, the characteristics of which is different from FCR output films, proved to be most preferable when the image processing is made with gamma 0.85 and 0.25 enhancement at spacial frequency of 0.17 cycle/mm. If the above ...
1993-01-01
A three-dimensional display system for brain CT images
International Nuclear Information System (INIS)
Commercially available CT devices reconstruct cross-sectional slices of the human body. A sequence of such abutting cross-sectional slices can be, and usually is, used to obtain information about the region of the head, which requires several slices to cover it. However, there are situations for which such asequence of displays is far from optimal - for example, when one would like to see the anatomic relationship between two features appearing in different slices or the shape of a particular region or tumor. The Computer Aided Three-Dimensional Reconstruction and Imaging System (CATRIS), developed at our university, can build up a three-dimensional image from a series of CT cross-sections and can display its stereoscopic image on a three-dimensional graphic display system, thus providing helpful information for clinical use in recognizing the anatomic relationship between two ...
Computed radiography. Evaluation of its role in the mass survey for lung cancer: Phantom study
Energy Technology Data Exchange (ETDEWEB)
In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in ...
1987-12-01
International Nuclear Information System (INIS)
In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in ...
1987-01-01
International Nuclear Information System (INIS)
A fast and accurate segmentation of organs at risk, such as the healthy colon, would be of benefit for planning of radiotherapy, in particular in an adaptive scenario. For the treatment of pelvic tumours, a great challenge is the segmentation of the most adjacent and sensitive parts of the gastrointestinal tract, the sigmoid and descending colon. We propose a semi-automated method to segment these bowel parts using the fast marching (FM) method. Standard 3D computed tomography (CT) image data obtained from routine radiotherapy planning were used. Our pre-processing steps distinguish the intestine, muscles and air from connective tissue. The core part of our method separates the sigmoid and descending colon from the muscles and other segments of the intestine. This is done by utilizing the ability of the FM method to compute a specified minimal energy functional integrated along a path, and thereby extracting the colon ...
2010-09-21
Energy Technology Data Exchange (ETDEWEB)
The aim of this study was to qualitatively and quantitatively study MR artifacts of various stents on the basis of in vitro experiments. We were particularly interested whether sequence type and orientation of the stent with respect to the static magnetic field influences the artifact. We examined 18 stents of different material (nitinol, stainless steel, cobalt alloy), different design of the stent meshes (AccuLink, OmniLink, DynaLink, Xact, Protoge, Wallstent Monorail), different diameter (5-10 mm) and different length (18-58 mm) with a turbo spin echo (TSE), a 2D-fast low angle shot (FLASH) and a 3D-FLASH sequence. The MR images were examined qualitatively with respect to possible artifacts. Furthermore we examined the MR data quantitatively: The contrast-noise-ratio (CNR) was determined both within the stent and outside (within the tube); based on these values we calculated the transparency factor P, furthermore we ...
2009-07-01
Energy Technology Data Exchange (ETDEWEB)
Purpose/Objective. Daily Cone-beam computed tomography (CBCT) in room imaging is used to determine tumour shrinkage during a full radiotherapy (RT) course. In addition, relative interfractional tumour and lymph node motion is determined for each RT fraction. Material and methods. From November 2009 to March 2010, 20 consecutive lung cancer patients (14 NSCLC, 6 SCLC) were followed with daily CBCT during RT. The gross tumour volume for lung tumour (GTV-t) was visible in all daily CBCT scans and was delineated at the beginning, at the tenth and the 20th fraction, and at the end of treatment. Whenever visible, the gross tumour volume for lymph nodes (GTV-n) was also delineated. The GTV-t and GTV-n volumes were determined. All patients were setup according to an online bony anatomy match. Retrospectively, matching based on the internal target volume (ITV), the GTV-t or the GTV-n was performed. Results. In eight patients, we observed a significant GTV-t shrinkage ...
2010-10-15
Use of microbes for paraffin cleanup at Naval Petroleum Reserve No. 3
Energy Technology Data Exchange (ETDEWEB)
Naval Petroleum Reserve No. 3 (NPR-3), also known as Teapot Dome, is a government-owned oil field in Natrona County, Wyoming. It is an asymmetrical anticline located on the western edge of the Powder River Basin, just south of the Salt Creek Anticline. Production started in 1922, and today the field is a marginally economic stripper field with average production of less than 3 BOPD (0.5 m{sup 3}/D) per well. Total field production is about 1,800 BOPD (286 m{sup 3}/D). The Second Wall Creek Formation was waterflooded from 1979 until June 1992 with poor results due to the extensive natural fracture system in this sandstone unit. Since water injection ceased, reservoir pressure has declined to very low levels. Liquids extraction and reinjection of the gas produced from high-GOR wells along the gas-oil contact continues, but the average gas cap pressure has fallen to approximately 150 ...
1995-12-31
Electron-beam welding of valve bodies; Elektronenstrahlschweissen von Armaturengehaeusen
Energy Technology Data Exchange (ETDEWEB)
In early March, 2000 a modern electron-beam welding facility for both series and one-off production of valves bodies (500 kg, up to 50 mm wall thickness) was commissioned at Josch Strahlschweisstechnik. Welding is performed under a fine vacuum. This permits not only the welding of components subject to acceptance inspection (HP0 approval), but also of special materials such as titanium, molybdenum, tungsten, Hastelloy and copper, and also their pairings. Products are developed and readied for production using modern 3D CAD software. A modern nine-axis control system makes it possible to produce sockets in pipe-on-pipe joints. (orig.) [German] Anfang Maerz 2000 wurde eine moderne Elektronenstrahlschweissanlage fuer die Herstellung von Armaturengehaeusen in Grossserien oder auch fuer Einzelfertigung (500 kg, bis 50 mm Wanddicke) bei der Josch Strahlschweisstechnik in Betrieb genommen. Die Schweissungen erfolgen im Feinvakuum. ...
2000-03-01
A field demonstration of the microbial treatment of sour produced water
Energy Technology Data Exchange (ETDEWEB)
The potential for detoxification and deodorization of sulfide-laden water (sour water) by microbial treatment was evaluated at a petroleum production site under field conditions. A sulfide-tolerant strain of the chemautotroph and facultative anaerobe, Thiobacillus denitrificans, was introduced into an oil-skimming pit of the Amoco Production Company LACT 10 Unit of the Salt Creek Field, Wyoming. Field-produced water enters this pit from the oil/water separation treatment train at an average flowrate of 5,000 bbl/D (795 m{sup 3}/D) with a potential maximum of 98,000 bbl/D (15,580 m{sup 3}/D). Water conditions at the pit inlet are 4,800 mg/l TDS, 100 mg/l sulfide, pH 7.8, and 107{degrees}F. To this water an aqueous solution of ammonium nitrate and diphosphorous pentoxide was added to provide required nutrients for the bacteria. The first 20% of the pit was aerated to a maximum depth of 5 ft (1.5 m) to ...
1995-12-31
MTF analysis of the MURR real-time neutron radiography facility
International Nuclear Information System (INIS)
In neutron radiography, as in other forms of NDE, it is sometimes desirable to observe dynamic events. This need has generated increased interest in real-time neutron radiography systems. As in other forms of radiography, a standard method for measuring the image forming capability of real-time systems is necessary in order to compare the various methods and systems used. A technique which has been used extensively in general photography and has been applied in the characterization of several screen-film combinations used in conventional neutron radiography is to determine the imaging system's modulation transfer function (MTF). This gives a graphical representation of the system's spatial resolution capabilities and was therefore chosen as the method for evaluation of the real-time neutron radiography facility at the University of Missouri ...
1982-04-01
Energy Technology Data Exchange (ETDEWEB)
Evaluation and interpretation of CT colonography is based on both 2D and 3D techniques. The 2D techniques are popular mainly because the time needed for evaluation is short. The 3D techniques allow better definition than the 2D techniques, especially of polyps close to folds or at the base of a fold. The evaluation strategies generally accepted so far (primarily 2D, with 3D for problem cases, or vice versa) demand knowledge of both 2D and 3D techniques. Newer 3D visualization techniques help make it possible to acquire more complete and faster recording particularly of areas that are not easily accessible to endoscopic examination. These user-friendly developments are thus well suited to improving the detection and the security of detection of polyps. It must be remembered that ...
2008-02-15
A Scheme of 3-D Breakdown-whip Analysis Methodology for High Energy Piping
Energy Technology Data Exchange (ETDEWEB)
High energy piping systems are operated with either or both conditions of maximum operating temperature exceeding 200 .deg. F(93.3 .deg. C) or maximum operating pressure exceeding 275 psig(19.3kg/cm{sup 2}) during normal operating conditions in nuclear power plants. A high energy pipe failure is postulated in branches or piping that runs larger than one inch nominal diameter. The resultant consequences of these postulated pipe breaks must be analyzed for the effect on maintenance of plant safe shutdown capability, containment integrity. And the analyzed results must be applied to the system design so that a pipe failure can not damage essential systems to an extent of impairing design function nor affect necessary component operability. The considerable effects of pipe break are as follows; dynamic effects such as pipe whip, jet impingement and environmental impact by release of system contents. Two ...
2007-10-15
Development of a neutron imaging facility at the CENM Al Maamora TRIGA
Energy Technology Data Exchange (ETDEWEB)
The field of neutron imaging has a broad scope of applications and has played a pivotal role in visualizing and quantifying hydrogenous masses in metallic matrices. The field continues to expand into new applications with the installation of new neutron imaging facilities. In this scope, a neutron imaging facility for computed tomography and real-time neutron radiography is currently being developed around 2.0 MW TRIGA MARK-II Reactor at Maamora Nuclear Research Centre in Morocco (CENM). The neutron imaging facility consists of a neutron collimator, a real-time neutron imaging system and imaging process systems. In order to reduce the gamma-ray content in the neutron beam, the reactor tangential channel was selected. For power of 250 kW, the corresponding thermal neutron flux measured at the inlet of the tangential ...
2009-07-01
Development of a neutron imaging facility at the CENM Al Maamora TRIGA
International Nuclear Information System (INIS)
The field of neutron imaging has a broad scope of applications and has played a pivotal role in visualizing and quantifying hydrogenous masses in metallic matrices. The field continues to expand into new applications with the installation of new neutron imaging facilities. In this scope, a neutron imaging facility for computed tomography and real-time neutron radiography is currently being developed around 2.0 MW TRIGA MARK-II Reactor at Maamora Nuclear Research Centre in Morocco (CENM). The neutron imaging facility consists of a neutron collimator, a real-time neutron imaging system and imaging process systems. In order to reduce the gamma-ray content in the neutron beam, the reactor tangential channel was selected. For power of 250 kW, the corresponding thermal neutron flux measured at the inlet of the tangential ...
2009-06-07
Neutron radiography with the cyclotron, 5
International Nuclear Information System (INIS)
Reliable facility of cyclotron-based real time neutron radiography system has been developed and applied to some industrial components. The equipment for neutron fluoroscopy is based on a sub-compact cyclotron and a LiF/ZnS (Ag) fluorescent screen viewed by a silicon intensifier target TV camera. The real time image is monitored on a CRT, recorded with a standard video recorder and processed by a digital image processor. The effectiveness of our real time neutron radiograph has been demonstrated to be applicable to not only the dynamic observation but also the magnifying and stereoscopic observation of fluoroscopic images. (author).
1987-01-01
[The study of the mixing layer by the point image method].
The properties of the mixing layer in dynamic systems were studied by the example of a mathematical model of the cubic image type. Its role in the generation of information and the evolution of its significance was shown. At the moment of generation, information is of zero significance, and this significance then increases. A criterion of efficiency was proposed, and the optimum moment of making a decision in creative work was determined. It was shown that the increase in the variability of the parameters of a living system upon entry into the mixing layer and its decrease upon exit can serve as objective indicators of the transition of the system from one dynamic regime (attractor) to another. PMID:12723364
Design of a neutron radiography collimator system in a through beam port at the TRIGA reactor
Energy Technology Data Exchange (ETDEWEB)
A neutron collimator system is being designed as part of a neutron imaging facility for computed tomography and real-time neutron radiography research at the through beam port of the University of Texas TRIGA reactor. Lack of sufficient information about collimator systems in a through port from the literature necessitated the use of Monte Carlo calculations using the MCNP code 3 to search for optimal design configuration and materials that maximize the thermal neutron intensity at the image plane while minimizing the fast neutrons and gamma radiation.
1996-12-31
''SEPIO NUANCE DT'' digital mammography system
International Nuclear Information System (INIS)
In the past, the need for high quality images, i.e., very sharp and clear images, in mammography have prevented mammography equipment from being digitalized; however, recent advances in detection technology such as development of a high resolution digital X-ray detector have produced improvements in digital mammography. Digital mammography is expected to replace conventional film-screen mammography. We have developed a digital mammography system, named ''SEPIO NUANCE DT'', which is equipped with a direct conversion flat panel detector. The present paper describes the high basic performance and user-friendly functions of the system. (author)
2007-03-01
International Nuclear Information System (INIS)
The purpose of this study is to develop a geometrically accurate imaging protocol at 3 T magnetic resonance imaging (MRI) for stereotactic radiosurgery (SRS) treatment planning. In order to achieve this purpose, a methodology is developed to investigate the geometric accuracy and stability of 3 T MRI for SRS in phantom and patient evaluations. Forty patients were enrolled on a prospective clinical trial. After frame placement prior to SRS, each patient underwent 3 T MRI after 1.5 T MRI and CT. MR imaging protocols included a T1-weighted gradient echo sequence and a T2-weighted spin echo sequence. Phantom imaging was performed on 3 T prior to patient imaging using the same set-up and imaging protocols. Geometric accuracy in patients and phantoms yielded comparable results for external fiducial reference deviations and internal landmarks between 3 T and 1.5 T MRI ...
2010-11-21
Computer vision algorithms in DNA ploidy image analysis
The high incidence and mortality rates of prostate cancer have stimulated research for prevention, early diagnosis and appropriate treatment. DNA ploidy status of tumour cells is an important parameter with diagnostic and prognostic significance. In the current study, DNA ploidy analysis was performed using image cytometry technique and digital image processing and analysis. Tissue samples from prostate patients were stained using the Feulgen method. Images were acquired using a digital imaging microscopy system consisting of an Olympus BX-50 microscope equipped with a color CCD camera. Segmentation of such images is not a trivial problem because of the uneven background, intensity variations within the nuclei and cell clustering. In this study specific algorithms were developed in Matlab based on the most prominent image segmentation ...
2006-03-01
% In this work we investigated, in the Smooth Particle Hydrodynamics (SPH) framework, the development of spiral structures and shock fronts in the radial flow of accretion discs in close binary systems. These shock waves take place when the initially supersonic radial flow penetrating the disc bulk, reduces substantially its speed becoming suddenly subsonic. To this purpose, keeping constant the mass of the compact primary (M1 = 1 MO ), the separation between the two components and the injection speed at the inner Lagrangian point L1 (close to the local sound speed), we carried out 2D SPH simulations for four values of the stellar mass ratio M2/M1. We worked out 2D models because the damping effect of the artificial viscosity is too strong in 3D. Furthermore, the 2D environment seems the most suitable in order to evidence shock fronts in highly compressible gases. The results show that spiral structures and shock fronts ...
2000-06-01
Nitrogen Requirements and Balance of Protected Cucumber in Coastal Lebanon
International Nuclear Information System (INIS)
Protected cultures are widespread along the Lebanese narrow coastline, encouraged by mild winter conditions. Although one of the most intensive production systems, water and nutrients managements are mostly empirical, based on the experience of the grower himself or of his workers. So far, water has been available in Lebanon, but it will become scarce within ten years. The conservation of water quality by a rational addition of nutrients is particularly relevant to protected cultures. This is important as greenhouses are developed on imported shallow soils that could be fragile and highly vulnerable to pollution. Sound management includes the amount and the forms of fertilizers as well as the modality of fertigation. An experiment was conducted during two spring seasons in a location along the northern coast in a typical unheated greenhouse. The cucumber response to two frequencies and modalities of fertigation was followed: continuous T2C and T3C and discontinuous ...
2003-10-01
Low-cost FPSO for service in the Zaafarana oil field
Energy Technology Data Exchange (ETDEWEB)
The Zaafarana oilfield development, operated by Zaafarana Oil Co. (Zafco) presented a series of unique challenges, including redeployment of an internal-turret mooring system, use of a turret-based electrical-cable jumper system, and permanent use of cable-deployed electric submersible pumps in the gravel-pack well completions. Following a detailed three-dimensional (3D) seismic program, the field was discovered by the first well in December 1990. Four subsequent appraisal wells were drilled. The discovery well and two of the appraisal wells tested oil at rates ranging from 2,000 to 10,100 B/D. Initial development plans called for the use of two conventional platforms with a pipeline to a shore-based treatment and storage terminal. Data acquired from subsequent wells were incorporated into the mapping and reserve estimates resulting in a sharp downgrade of the estimated recoverable reserves. The reduced ...
1997-04-01
Aspects of Stability Related to the Colliding Beam Fusion = Reactor
Recent experiments with TFTR, D-III-D and JET involving the injection and trapping of low density beams of high energy large orbit ions indicate that large orbit non-adiabatic ions slow down and diffuse classically in the presence of anomalous fluctuations and transport of adiabatic majority particles. Accordingly, we consider conceptual fusion reactors(N. Rostoker, M.W. Binderbauer and H.J. Monkhorst, Science) 278, 1419 (1997). based on classical confinement of fuel ions and fusion products(M.W. Binderbauer and N. Rostoker, J. Plasma Phys.) 56, 451 (1996).. The magnetic confinement geometry of the proposed designs is a Field Reversed Configuration. A survey of experimental results on instabilities and their characteristics as related to these reactor concepts is presented. Particular focus will be given to long wavelength (as compared to gyro-radius) and low frequency (?<< c/r_o, r_o=3D major radius of annular current ring) instabilities ...
1998-11-01
Analysis and evaluation of seismic response of reactor building for Daya Bay Nuclear Power Plant
International Nuclear Information System (INIS)
Daya Bay NPP has been operating safely and stably over 10 years since 1994, and its' seismic analysis of nuclear island was in accordance with the approaches in RCC-G standard for the model M310, in which the Simplified Impedance Matrix Method (SIMM) was employed for the consideration of SSI. Thanks to the rapid progress being made in upgrading the evaluation technology and the capability of data processing systems, methods and software tools for the SSI analysis have experienced significant development all over the world. Focused on the model of reactor building of the Daya Bay NPP, in his paper the more sophisticated 3D half-space continuum impedance method based on the Green functions is used to analyze the functions of the soil, and then the seismic responses of the coupled SSI system are calculated and compared with the corresponding design values. It demonstrates that the design method provides a ...
2005-12-01
Evaluation of performance and characteristics of neutron radiography and standardization
Energy Technology Data Exchange (ETDEWEB)
Neutron radiography has been put to practical use in foreign countries as one of nondestructive inspection technologies, but in Japan, its application to other scientific fields is mainly researched. The reason is, the neutron radiography apparatuses installed in Japan are hard to be industrially utilized for a number of reasons, but also the characteristics of neutron radiography are not clearly established, and it is not standardized. The part from a collimator through an object to a detector is called ``upstream``, the part of an image detector is called ``midstream``, and the part of image processing is called ``downstream``. The nonparallel property of beam, image distortion and the lack of sharpness, beam quality and the interaction of neutron beam with an object are discussed about the upstream. The intensity of neutron beam, the energy spectra, the effective total macroscopic cross section, the effective energy, the ...
1995-02-01
International Nuclear Information System (INIS)
The neutron radiography facility was installed at the tangential beam port of the 3 MW TRIGA MARK-II research reactor. In the facility only direct film neutron radiography method is being used. The project involves development of electronic imaging system for real time neutron radiography in the existing facility with the aim of utilizing it for research and industrial applications. In establishing the electronic imaging system for real time neutron radiography the improvements of existing facility were almost done during this period. In parallel, the former facility was used for the research: (a) A study of wood and wood plastic composites with and without additive by using film neutron radiography and (b) A study of jute reinforced polymer composites by using film neutron radiography technique. (author)
2008-09-01
International Nuclear Information System (INIS)
We measured and evaluated digital, pre-sampling and overall imaging properties (characteristic curve, modulation transfer function (MTF), Wiener spectrum (WS), noise equivalent quanta (NEQ)) for Cannon's flat-panel detector (FPD), Fuji computed radiography (FCR) and screen-film (S/F) systems, respectively. First, the digital and overall characteristic curves of FPD and FCR systems were more wide dynamic range than that of the S/F system. Second, the pre-sampling and overall MTF of FPD system were better than those of FCR system a little at lower spatial frequencies than 0.8 mm"-"1, but the overall MTF of FPD and FCR systems were worse than that of S/F system a little at all spatial frequencies. Third, the digital and overall WS of FPD system were similar or better than those of FCR ...
2002-12-01
Energy Technology Data Exchange (ETDEWEB)
We measured and evaluated digital, pre-sampling and overall imaging properties (characteristic curve, modulation transfer function (MTF), Wiener spectrum (WS), noise equivalent quanta (NEQ)) for Cannon's flat-panel detector (FPD), Fuji computed radiography (FCR) and screen-film (S/F) systems, respectively. First, the digital and overall characteristic curves of FPD and FCR systems were more wide dynamic range than that of the S/F system. Second, the pre-sampling and overall MTF of FPD system were better than those of FCR system a little at lower spatial frequencies than 0.8 mm{sup -1}, but the overall MTF of FPD and FCR systems were worse than that of S/F system a little at all spatial frequencies. Third, the digital and overall WS of FPD system were similar or better than those of FCR ...
2002-12-01
Imaging properties of the Medipix2 system exploiting single and dual energy thresholds
Low noise, high resolution and high dose efficiency are the common requirements for most X-ray imaging applications. Especially in medical applications the dose efficiency is a necessity for detector systems. We present the imaging performance of the Medipix2 readout chip bump bonded to a 300 mu m thick Si detector as a function of the detection threshold, a free parameter not available in conventional integrating imaging systems. Spatial resolution has been measured using the modulation transfer function (MTF) and it varies between 8.2 Ip/mm and 11.0 Ip/mm at 70%. An associated measurement of noise power spectrum (NPS) permits us to derive the detective quantum efficiency (DQE) which can be as a high as 25.5 % for a broadband incoming spectrum. The influence of charge diffusion in the sensor together with threshold variation in the readout chip is discussed. Although the Medipix2 ...
2006-01-01
Spectral characteristics of lignite open cast mining systems: a preliminary status
Energy Technology Data Exchange (ETDEWEB)
The application of a Compact Airborne Spectrographic Imager to assessment and monitoring of lakes in a lignite open cast mining area in central Germany is described. The imager was used in combination with additional ground experiments, such as field spectroscopy and water sampling. The spectral characteristics of an instrument under development for monitoring geochemical and hydrological processes are presented. Summary form only.
1999-07-01
Model of quantum noise of shadow radiation images
International Nuclear Information System (INIS)
Correlation characteristics of quantum noise on the shadow radiation image (RI) of the object under nondestructive testing are studied. Mathematical model of RI occasional distortions is derived. The model takes into account the parameters of object under testing and of radiation beam by radiation quanta flux density. The results obtained can be used as a component in the process of investigation of various radiation testing systems
Imaging findings of central nervous system neuroepithelial cysts
Energy Technology Data Exchange (ETDEWEB)
Neuroepithelial cysts are rare and mostly asymptomatic cerebrospinal fluid (CSF)-like cysts. We describe herein the imaging findings in five patients with neuroepithelial cysts. Two cases of proven and three of presumed neuroepithelial cysts are presented. Three of five are located in the thalamus, a location which is not characteristic for neuroepithelial cysts. In the case of incidental finding of asymptomatic neuroepithelial cyst, clinical and radiological follow-up is indicated and surgical intervention is not necessarily warranted. (orig.) With 5 figs., 6 refs.
1998-05-01
Diagnostic imaging of the acutely injured patient
Energy Technology Data Exchange (ETDEWEB)
This book provides an analysis of pathophysiologic concepts of trauma and reviews the effectiveness of the available imaging modalities in acute trauma of various organ system. Topics covered are chest injuries; abdominal trauma; fractures of long bones; the foot and ankle; the knee; hand and wrist; the elbow; the shoulder; the pelvis hips; the spine; the skull and facial trauma and the clinical assessment of multiple injuries patients. Comparative evaluation of diagnostic techniques of radiography is discussed. Normal anatomy and bone fractures along with soft-tissue injuries are described.
1985-01-01
Study of spatial resolution in three-dimensional rotational angiography
International Nuclear Information System (INIS)
In interventional radiology (IVR) of cerebral aneurysms, it is important to understand the form and physical relationships between the cerebral aneurysm and the surrounding vessels. However, because the vessels in the head area are highly complex, it can be difficult to comprehend the structure using conventional angiography. Therefore, three-dimensional rotational angiography (3D-RA) has been used in recent years. This article discusses studies of the spatial resolution of 3D-RA. We reconstructed 3D-RA of an acrylic slit phantom (slit widths: 0.5, 0.75, 1.0, 1.5 mm) and examined spatial resolution by visual evaluation and profile curves. When the slit phantom was arranged to avoid the effect of beam hardening, the spatial resolution of 3D-RA was found to be as high as 0.75 mm. When the slit phantom was placed orthogonal ...
2006-03-01
Energy Technology Data Exchange (ETDEWEB)
A 2-D model has been proposed to investigate the approximate estimation of the natural convection heat loss from modified cavity receiver of without insulation (WOI) and with insulation (WI) at the bottom of the aperture plane in our previous article. In this paper, a 3-D numerical model is presented to investigate the accurate estimation of natural convection heat loss from modified cavity receiver (WOI) of fuzzy focal solar dish concentrator. A comparison of 2-D and 3-D natural convection heat loss from a modified cavity receiver is carried out. A parametric study is carried out to develop separate Nusselt number correlations for 2-D and 3-D geometries of modified cavity receiver for estimation of convective heat loss from the receiver. The results show that the 2-D and 3-D are comparable only at higher angle of ...
2009-10-15
Refrigerator operating experience on whole body MRI magnet systems
International Nuclear Information System (INIS)
Several refrigerators for liquid helium and liquid nitrogen systems have been integrated successfully into IGC manufactured whole body Magnetic Resonance Imaging (MRI) magnet systems. The refrigerators have been tested in systems with magnetic fields of 0.6T to 1.5T. Tests were performed to study the effectiveness of the refrigerators, the magnetic field effects on the refrigerators, the effect of the refrigerators on the field uniformity and magnetic resonance image quality. The interface between the refrigerator and the whole body MRI magnet system cryostat was specifically designed to allow retrofit to the existing IGC magnet systems, while ensuring good heat transfer characteristics and good vibration isolation from the cryostat. The interface between the refrigerator and the cryostat and the refrigerator test results are presented.
1985-08-01
Scoring of brain maturation in developmentally handicapped children with high-field MR imaging
International Nuclear Information System (INIS)
A four-stage scoring system for brain maturation was established with MR imaging. First, gyration and myelination were analyzed in 50 anamnestically normal children (32-240 weeks postconceptional age). Subsequently 60 patients (same age range) with birth asphyxia, seizures, or developmental delays were evaluated analogously. T1- and T2-weighted images (500/30 and 3,000/120 [repetition time msec/echo time msec]) were obtained with a 2.35-T magnet in all children. Whereas gyration abnormalities were seen in some patients, all handicapped children presented with delayed myelination. In conclusion, prospective staging of brain development (gyration and myelination) is possible and is best obtained with T2-weighted images.
Pharmaceutical applications of non-linear imaging
British Library Electronic Table of Contents (United Kingdom)
Non-linear optics encompasses a range of optical phenomena, including two- and three-photon fluorescence, second harmonic generation (SHG), sum frequency generation (SFG), difference frequency generation (DFG), third harmonic generation (THG), coherent anti-Stokes Raman scattering (CARS), and stimulated Raman scattering (SRS). The combined advantages of using these phenomena for imaging complex pharmaceutical systems include chemical and structural specificities, high optical spatial and temporal resolutions, no requirement for labels, and the ability to image in an aqueous environment. These features make such imaging well suited for a wide range of pharmaceutical and biopharmaceutical investigations, including material and dosage form characterisation, dosage form digestion and drug rele...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
Summation Copper-64 (T1/2?=?12.7 hours; ?+, 0.653?MeV [17.8 %]; ??, 0.579?MeV [38.4 %]) has decay characteristics that allow for positron emission tomography (PET) imaging and targeted radiotherapy of cancer. The well-established coordination chemistry of copper allows for its reaction with a wide variety of chelator systems that can potentially be linked to peptides and other biologically relevant small molecules, antibodies, proteins, and nanoparticles. The 12.7-hours half-life of 64Cu provides the flexibility to image both smaller molecules and larger, slower clearing proteins and nanoparticles. In a practical sense, the radionuclide or the 64Cu-radiopharmaceuticals can be easily shipped for PET imaging studies at sites remote to the production facility. Due to the versatility of 64Cu, ...
2009-01-01
Comparison of fluid-dynamic modeling of flow with velocity-encoded MR imaging
International Nuclear Information System (INIS)
This paper develops a fluid dynamic model using finite difference methods characterizing flow in phantoms simulating in vivo conditions and to compare those results with velocity encoded MR images. The phantom consisted of 1-inch (2.5-cm) tubing with semicircular insert and fluid with viscosity, T1, and T2 comparable to blood. Numeric solutions to Navier-Stokes equations for this system were obtained using finite difference methods, with velocity input function of zero at walls and parabolic at both ends. In resulting color raster (CR) images, color temperature represented velocity value. In velocity-encoded MR images acquired under the same flow conditions, phase is proportional to average velocity during application of flow-encoding gradients. Because these gradients are applied along one direction per acquisition, magnitude and direction of velocity are obtained.
1990-11-25
Automatic Extraction of Open Space Area from High Resolution Urban Satellite Imagery
In the 21st century, Aerial and satellite images are information rich. They are also complex to analyze. For GIS systems, many features require fast and reliable extraction of open space area from high resolution satellite imagery. In this paper we will study efficient and reliable automatic extraction algorithm to find out the open space area from the high resolution urban satellite imagery. This automatic extraction algorithm uses some filters and segmentations and grouping is applying on satellite images. And the result images may use to calculate the total available open space area and the built up area. It may also use to compare the difference between present and past open space area using historical urban satellite images of that same projection
2011-01-01
Angiography of the head using Fuji computed radiography (FCR) system
International Nuclear Information System (INIS)
Forty-seven subtraction images of FCR were compared with subtraction images of conventional angiography of the head. Quality of the FCR images were equal or superior to that of conventional angiography. Antero-posterior projection of external carotid arteriography by FCR was most useful because of its wide dynamic range. As contrast resolution of FCR is superior to that of conventional angiography, only half diluted contrast media was needed. As for spacial resolution, FCR is slightly inferior to conventional angiography. However, most vessels which are clinically important were adequately demonstrated. A weak point of FCR which should be improved is relatively long time to process the images after radiation exposure. (author).
1985-01-01
Collaboration work for nuclear power building using 3D CAD information
Energy Technology Data Exchange (ETDEWEB)
In the construction work for the Unit No.5 Turbine Building at Hamaoka Nuclear Power Station, the collaboration work for the planning and the coordination of the building construction and the machinery installation was carried out utilizing three-dimensional computer aided design (3D CAD) information. It was the first time in Japan for a building constructor and a plant manufacturer to work together, exchanging 3D CAD data of the whole building and adjusting the construction schedule. It was made possible to confirm the correspondence concerning the planning of both companies from the primary stage of the project by the total process simulation and to adjust on-going work precisely by the partial process simulation.
2006-02-15
Collaboration work for nuclear power building using 3D CAD information
International Nuclear Information System (INIS)
In the construction work for the Unit No.5 Turbine Building at Hamaoka Nuclear Power Station, the collaboration work for the planning and the coordination of the building construction and the machinery installation was carried out utilizing three-dimensional computer aided design (3D CAD) information. It was the first time in Japan for a building constructor and a plant manufacturer to work together, exchanging 3D CAD data of the whole building and adjusting the construction schedule. It was made possible to confirm the correspondence concerning the planning of both companies from the primary stage of the project by the total process simulation and to adjust on-going work precisely by the partial process simulation.
2006-02-01
Antimalarial activity of selected Sudanese medicinal plants with emphasis to Maytenus senegalensis
International Nuclear Information System (INIS)
The aim of the present study is to identify and characterize the antimalrial agents from traitional Sudanese medicinal plants. 49 plants parts representing 26 species from 15 families were extracted and screened for their in vitro antimalrial activity using P. falciparum strain 3D7 which is chloroquine sensitive and Dd2 strain which is chloroquine resistant and pyrimethamine sensitive.The plant species investigated exhibited diverse botanical families. They includes Annonaceae, Aristolochiaceae, Asteraceae, Balantiaceae, Caesalpiniceae, Celasteraceae, Cucurbitaceae, Fabaceae, Graminae, Meliaceae, Myrtaceae, Polygonaceae, Rubiaceae, Rutaceae, and simaroubaceae. The evaluation of these plants for their antimalarial activity and their effect on lymphocyte proliferation was carried out. 57 extracts were tested on the chloroquine sensitive strain (3D7). Where 34 extracts (59%) exhibited significant activity ...
Energy Technology Data Exchange (ETDEWEB)
Objective: To determine the reproductibility of three-dimensional volume and thickness measurements of the knee joint cartilage with MRI in volunteers. Methods: The knees of 7 healthy individuals (ages 23 to 58 yrs.) were sagitally imaged with a resolution of 2x0.31x0.31 mm{sup 3}, using a fat-suppressed FLASH-3 D sequence. The knee was repositioned in between replicate acquisitions, 6 data sets being obtained in each case. After semiautomatic segmentation and three-dimensional reconstruction of the cartilage, the thickness was determined independent of the original section orientation. The coefficient of variation for repeated volume measurements and the deviations of the maximal cartilage thickness values were calculated subsequently. Results: The mean variation of the cartilage volumes of the replicate measurements was 1.4% ({+-}0.8%) in the patella, 1.7% ({+-}1.5%) in the femur, 3.0% ({+-}1.2%) in the medial tibial ...
1997-12-01
Direct Comparison of the X-Ray Emission and Absorption of Cerium Oxide
Energy Technology Data Exchange (ETDEWEB)
Bremstrahlung Isochromat Spectroscopy (BIS). The XES spectra were collected using a Specs electron gun for the excitation and the XES 350 grating monochromator and channel plate system from Scienta as the photon detection. Spectra were collected in 'normal mode,' where the electron gun kinetic energy (KE) and the energy position of the center of the channel plate were both fixed and the energy distribution in the photon (hv) spectrum was derived from the intensities distributed across the channel plate detector in the energy dispersal direction. The polycrystalline Ce sample was oxidized by exposure to air at ambient pressures. After introduction to the ultra-high vacuum system, the oxidized sample was bombarded with Ar, to clean the topmost surface region and stabilize the surface and near surface regions. Although CeO{sub 2} would be the thermodynamically preferred composition in an oxygen rich environment, the combination ...
2010-11-24
... and/or hearing mechanisms. Seven papers dealt with 3D audio technology and/or its application. Eight papers presented ...
2005-04-01
Tackling the Steroid Issue: Squeezing Out the Juice
... Neglect (12) Co-Occurring Disorders (75) Conduct Disorders (3) D Dementia (2) Depression (51) Driving While Intoxicated (17) ...
English version - Guidelines for Viability Assessment - CAP Workbook version 3_d
Guidelines for the viability primer component of the version 3 workbook. The Viability page in the current version of the Excel spreadsheet for conservation ... ...
British Library Electronic Table of Contents (United Kingdom)
A 2-D model has been proposed to investigate the approximate estimation of the natural convection heat loss from modified cavity receiver of without insulation (WOI) and with insulation (WI) at the bottom of the aperture plane in our previous article. In this paper, a 3-D numerical model is presented to investigate the accurate estimation of natural convection heat loss from modified cavity receiver (WOI) of fuzzy focal solar dish concentrator. A comparison of 2-D and 3-D natural convection heat loss from a modified cavity receiver is carried out. A parametric study is carried out to develop separate Nusselt number correlations for 2-D and 3-D geometries of modified cavity receiver for estimation of convective heat loss from the receiver. The results show that the 2-D and 3-D are comparabl...
2009-01-01
Advanced 3D Visualization Web Technology and its Use in ...
... applications related to military and intelligence area ... the technology solved yet, but the open issue still ... fields, columns; ie data source, document type ...
2002-04-01
AIAA 20033400 CFD Sensitivity Analysis ... - FUN3D Manual - NASA
mulation, with flow quantities stored at the grid vertices. OVERFLOW ..... attack: a separation bubble near the trailing edge of the ..... AGARD CP-429, Jul. 1988. ...
Verification of electron beam therapy with storage phosphor images: Precision of field placement
Energy Technology Data Exchange (ETDEWEB)
Portal verification images were generated from the photon contamination in electron beams produced by a linear accelerator during treatment of patients receiving high-energy electron radiation therapy (8-14 MeV). An experimental storage phosphor system was used to record the images and display them on laser-printed film. Images were obtained from four or more treatment fractions from 21 cases of head and neck cancer. Precision in field placement was estimated by determining the position of a selected anatomic landmark relative to the center of the field for each series of images. The average standard deviation in the field-position measurements was 3.8 mm. Several procedural problems were also detected and corrected after review of the verification images. The results indicate that the emphasis placed on monitoring and control of field-positioning error in ...
1990-04-01
Improvement of FCR-linear tomography using digital image processing
Energy Technology Data Exchange (ETDEWEB)
In order to improve the image quality of linear tomography performed with the Fuji Computed Radiography (FCR) system, we have examined one-dimensional unsharp mask filtering to reduce blur formed in the direction of tomographic swing. We determined a mask size and a weighting factor of the image processing suitable to obtain a quality tomogram. The mask size of 41 x 1 pixels for a 14 x 14'' imaging plate, which modifies the original image date and results in demonstrating a peak frequency at 0.2 cycles/mm for spatial frequency spectrum, is superior in showing fine vessel structures and morphological features of pathology in the lung fields. An additional spatial frequency filtration in the direction perpendicular to the tomographic movement reduces the blur and clearly demonstrates object contours running parallel to the tube movement. However, the additional ...
1994-02-01
Fluorescence based molecular in vivo imaging; Fluoreszenzgestuetzte molekulare Bildgebung in vivo
Energy Technology Data Exchange (ETDEWEB)
Molecular imaging represents a modern research area that allows the in vivo study of molecular biological process kinetics using appropriate probes and visualization methods. This methodology may be defined- apart from the contrast media injection - as non-abrasive. In order to reach an in vivo molecular process imaging as accurate as possible the effects of the used probes on the biological should not be too large. The contrast media as important part of the molecular imaging can significantly contribute to the understanding of molecular processes and to the development of tailored diagnostics and therapy. Since more than 15 years PTB is developing optic imaging systems that may be used for fluorescence based visualization of tissue phantoms, small animal models and the localization of tumors and their predecessors, and for the early recognition of inflammatory processes in ...
2008-12-15
Energy Technology Data Exchange (ETDEWEB)
The principle of radiodiagnosis consists in the fact the X-ray beam is attenuated at different degrees by distinct tissues. For this reason, the anatomical structures have distinct radiological opacities, that produce the radiographic image. The progresses in radiology are related to the development if new radiographic image formation systems that enable an amplification in the quality, with low dose and/or risk to the patient. The objective of this work is the sensitometric valuation of a screen-film combination, that is still the most used, for the standardization, of radiographic images. Thinking about this, were constructed homogeneous phantoms of the chest, skull and pelvis, for the calibration of X-ray beams, with the purpose of obtaining radiographic images of good quality, basing in the routine of a radiodiagnosis service and in the scientific knowledge. Questions were ...
1996-12-31
Energy Technology Data Exchange (ETDEWEB)
Objective. To compare turbo inversion recovery magnitude (TIRM) with standard T1-weighted (T1-W) and T2-weighted (T2-W) MR sequences in the very early detection of acute osteomyelitis in children. Materials and methods. In 15 children with osteomyelitis, 15 sets of T1-W spin-echo (SE) (TR/TE, 400-640/12-17), T2-W turbo spin-echo (TSE) (TR/TE/ETL, 3290-4465/112-120/11), and TIRM (TR/TE/TI, 4000-6120/60/160) images were acquired with a 1.0-T magnet. Contrast-to-noise (C/N) ratios and percentage of signal between lesion and normal bone marrow were analysed with a computer-assisted image analysing system in a region of interest (ROI). Results. In 13 of 15 patients, the absolute signal enhancement in a ROI on the TIRM images was better than on the T1-W SE and T2-W TSE images and in 14 of 15 cases, C/N ratios were also better on the TIRM images than on the other ...
1998-11-01
Recent developments and applications for the University of Texas thermal neutron imaging facility
Energy Technology Data Exchange (ETDEWEB)
The full text follows. A thermal neutron imaging facility (TNIF) capable of real time neutron radiography and computed tomography was developed for the University of Texas TRIGA Mark II (UT-TRIGA) reactor from 1994-1998. The facility was developed with a through reactor beam port capable of producing a 5.2 x 10{sup 6} n/cm{sup 2}/s thermal neutron flux with a gamma dose rate of less than 1 mR/s after collimation. The original TNIF included the UT-TRIGA reactor, neutron collimation array, sample positioning system, neutron image intensifier tube, video camera, computerized image acquisition system, and a radiation shield. A 0.7 mm slit in cadmium was easily detectable using neutron radiography, and 1.4 mm diameter holes bored in an aluminum block were easily resolved using computed neutron tomography. Precise lower limits of the system resolution have hot been ...
2001-07-01
UK PubMed Central (United Kingdom)
Microbes in nature frequently function as members of complex multitaxon communities, but the structural organization of these communities at the micrometer level is poorly understood because of limitations...Full Text Available
2011-03-08
Silica-Based Nanoparticle Uptake and Cellular Response by Primary Microglia
UK PubMed Central (United Kingdom)
BackgroundSilica nanoparticles (SiNPs) are being formulated for cellular imaging and for nonviral gene delivery in the central nervous system (CNS), but it is unclear what potential...Full Text Available
2010-05-01
UK PubMed Central (United Kingdom)
BackgroundMagnetic Resonance Imaging scanners have become ubiquitous in hospitals and high-field systems (greater than 3 Tesla) are becoming increasingly common. In light of recent...Full Text Available
Proceedings of the eighth West Virginia University international mining electrotechnology conference
Energy Technology Data Exchange (ETDEWEB)
A total of 25 papers were presented at the conference in 6 sessions: illumination and communication; power and safety; knowledge based systems; mine-wide monitoring; instrumentation control and automation; remote sensing and imaging.
1986-01-01
UK PubMed Central (United Kingdom)
Arriving at a firm diagnosis of neurosarcoidosis continues to pose serious problems, particularly when evidence of granulomatous disease outside the nervous system is lacking. The commonest mode of...Full Text Available
1991-06-01
Generation and control of sound bullets with a nonlinear acoustic lens
UK PubMed Central (United Kingdom)
Acoustic lenses are employed in a variety of applications, from biomedical imaging and surgery to defense systems and damage detection in materials. Focused acoustic signals, for example, enable ultrasonic...Full Text Available
2010-04-20
Fragment-Based Learning of Visual Object Categories in Non-Human Primates
UK PubMed Central (United Kingdom)
When we perceive a visual object, we implicitly or explicitly associate it with an object category we know. Recent research has shown that the visual system can use local, informative image fragments...Full Text Available
Evaluation of a filmless radiology pilot--a preliminary report.
UK PubMed Central (United Kingdom)
The development of the Multimedia Electronic Medical Record System (MEMRS) promises new opportunities to significantly reduce the routine use of film as the medium for viewing radiological medical images....Full Text Available
2001-01-01
Double-Valve Libman-Sacks Endocarditis Causing Ventricular Fibrillation Cardiac Arrest
UK PubMed Central (United Kingdom)
Libman-Sacks endocarditis is a well-known and rather common cardiac manifestation of systemic lupus erythematosus. Transesophageal and transthoracic echocardiography are the definitive imaging methods...Full Text Available
2011-01-01
UK PubMed Central (United Kingdom)
Simplification of cell enumeration technologies is necessary, especially for resource-poor countries, where reliable and affordable enumeration systems are greatly needed. In this paper, an immunomagnetic...Full Text Available
2007-04-01
British Library Electronic Table of Contents (United Kingdom)
Subject of this study is the question of whether cone beam CT (CBCT) images with reduced projection data are suitable for use in adaptive radiation therapy (ART) treatment planning. For this purpose image quality and dose calculation accuracy depending on imaging modality were analysed. In this context, two CBCT-methods will be indicated having reduced projection data sets: Scans acquired with 200^o rotation angle in order to accelerate the CBCT process (half scan), or scans with an asymmetric cone beam and detector offset, used to enlarge the field-of-view (half fan). Methods: For three different CBCT-modes (On-Board-Imaging, Varian Medical Systems), two of them based on reduced projection data, and a conventional multidetector CT system, the main image quality parameters were studied. Tr...
2011-01-01
Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures
Energy Technology Data Exchange (ETDEWEB)
AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the ...
2002-04-01
Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures
International Nuclear Information System (INIS)
AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the ...
2002-04-01
The profusion of online digital images presents new challenges for image indexing. Images have always been problematic to describe and catalogue due to lack of inherent textual data and ambiguity of meaning. An alternative to time-consuming professionally-applied metadata has been sought in the form of tags, simple keywords that form a flat structure known as distributed classification, or more popularly as a folksonomy. This research aims to increase understanding of why people tag and how effective they find it for searching, using as the focus. Open-ended questionnaires were sent out to members of the photo-sharing website Flickr, with the opportunity to post comments to an online discussion space. There is also a systematic comparison between a tag-based system and a more traditional controlled vocabulary, to test out the claims made regarding the suitability of tagging for searching and browsing. ...
2009-01-01
Calibration of Initial Measurements from the Full Aperture Backscatter system on NIF
Energy Technology Data Exchange (ETDEWEB)
The Full Aperture Backscatter System (FABS) provides a measure of the spectral power, and integrated energy scattered by stimulated Brillouin (348-354 nm) and Raman (400 - 700 nm) scattering into the final focusing lens of the first four beams of the NIF laser. The system was designed to provide measurements at the highest expected fluences with: (1) spectral and temporal resolution, (2) beam aperture averaging, and (3) near-field imaging. This is accomplished with a strongly attenuating diffusive fiber coupler and streaked spectrometer and separate calibrated time integrated spectrometers, and imaging cameras. Measurement of the wavelength dependent sensitivity of the complete system is accomplished with a calibrated Xe lamp. Data from the calibration system is combined with experimental data to produce the power and energy measurements. Examples of ...
2004-04-01
International Nuclear Information System (INIS)
In this thesis, a new ab-initio method for molecular dynamics within the framework of density functional theory was developed and implemented. It is strongly related to the projector-augmented-wave method (PAW) by P. Bloechl, but also includes elements of a pseudocharge method proposed by M. Weinert for the full-potential linearized augmented plane wave method (FLAPW). Like the FLAPW-method, the PAW-method is an all-electron method. In the later case, the hamiltonian takes quite a simple form similar to the one obtained when using normconserving Kleinman-Bylander-type pseudopotentials or ultrasoft Vanderbilt pseudopotentials. The PAW-method allows for an efficient calculation of systems containing virtually any element of the periodic table, including those which require high numerical effort when treated using normconserving pseudopotentials (e.g. 2p-elements like oxygen or 3d-transitional metals like copper). In addition, ...
Re-evaluation of floor response spectra of reactor building for Daya Bay NPP
International Nuclear Information System (INIS)
The seismic analysis of nuclear island of Daya Bay Nuclear Power Plant (NPP) was just in accordance with the approaches in RCC-G standard for the model M310 in France, in which the simplified impedance matrix method was employed for the consideration of soil's function. In this paper the more sophisticated 3D half-space continuum impedance method based on the Green functions is used to analyze the function of soil. In addition, multi-group of input time histories was used in the seismic response analysis in the existing design and their average of responses for each group was taken as the design basis. The same multi-group of input time histories was used in the seismic response analysis in this study, but the average and enveloped value of responses for each case are calculated respectively to account for the uncertainty of input motions. Focused on the above two issues, the seismic responses of the reactor building are calculated and the ...
2006-03-01
Long-life bismuth liquid metal ion source for focussed ion beam micromachining application
International Nuclear Information System (INIS)
Liquid metal ion sources (LMISs) with Ga as ion species are widely used in focused ion beam (FIB) technology for micromachining and surface treatment on the sub-micron and nano-scale. Key features of a LMIS for investigating mechanical properties and 3D-microfabrication of materials are long life-time, high brightness, stable ion current and a highly effective milling ability for the material to be modified. In order to increase the material removal rate, heavier ions than Ga and their clusters should be applied. Bismuth (Bi) is the heaviest, non-radio-active element in the periodic table, is non-toxic and exhibits a low melting point. We have thus produced a long-life (about 1000 h) Bi LMIS with a good beam performance, applicable in any FIB system. Since Bi is the only element in this source, it is not necessary to separate it from other ions by a mass filter. Investigation of the sputtering rate of NiTi shape memory ...
2008-09-15
Holography of a Composite Inflaton
We study the time evolution of a brane construction that is holographically dual to a strongly coupled gauge theory that dynamically breaks a global symmetry through the generation of an effective composite Higgs vev. The D3/D7 system with a background magnetic field or non-trivial gauge coupling (dilaton) profile displays the symmetry breaking. We study motion of the D7 brane in the background of the D3 branes. For small field inflation in the field theory the effective Higgs vev rolls from zero to the true vacuum value. We study what phenomenological dilaton profile generates the slow rolling needed, hence learning how the strongly coupled gauge theory's coupling must run. We note that evolution of our configuration in the holographic direction, representing the phyiscs of the strong interactions, can provide additional slowing of the roll time. Inflation seems to be favoured if the coupling changes by only a small amount ...
2010-01-01
Development status of a small, direct-injection diesel engine at Isuzu
Energy Technology Data Exchange (ETDEWEB)
Development status of small direct injection diesel engine at Isuzu Motors Ltd. is reviewed. There is much difficulty in combustion optimization of small DI engines, due to small combustion chamber volume, large surface to volume ratio, wide engine speed range and so on. Novel ideas in the area of injection system, combustion chamber and induction swirl were tried to solve these problems and their effects are presented here. Our prototype DI engines which adopted some of these ideas has turned out to have better fuel economy by about 15 percent, 2 - 3 dB(A) higher noise level than IDI and almost the same power output performance as IDI. As to exhaust emissions, they have a possibility to conform to '86 California emission standards, in inertia weight classes up to 2625 LBS. The remaining problem areas are noise emission, durability of injection pump and cabin heater performance. These problems must be solved by ...
1985-01-01
The influence of scattered radiation on recording systems and quality-assurance test parameters
International Nuclear Information System (INIS)
Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).
1988-02-23
The influence of scattered radiation on recording systems and quality-assurance test parameters
International Nuclear Information System (INIS)
Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).
International Nuclear Information System (INIS)
There is an increasing interest in using novel methods to generate electrical energy using wind and solar energy sources. Unfortunately, such energy sources are intermittent, and, therefore, conventional sources must still be available to meet demand during critical periods. In addition, renewable energy technologies are still expensive in general, although extensive research programs are being conducted to overcome this disadvantage. Hence, reliability, economic assessment and environmental impacts are three objectives to be satisfied simultaneously when designing either an autonomous or a grid-connected hybrid power generation system. The installation of any of these two systems should, undoubtedly, be preceded by an assessment of the available resources at the candidate site. In addition, many other factors are to be studied, including economics of transmission lines, site constraints, distances etc. In this thesis, the subjective judgments ...
Energy Technology Data Exchange (ETDEWEB)
Reliable facility of cyclotron-based real time neutron radiography system has been developed and applied to some industrial components. The equipment for neutron fluoroscopy is based on a sub-compact cyclotron and a LiF/ZnS (Ag) fluorescent screen viewed by a silicon intensifier target TV camera. The real time image is monitored on a CRT, recorded with a standard video recorder and processed by a digital image processor. The effectiveness of our real time neutron radiograph has been demonstrated to be applicable to not only the dynamic observation but also the magnifying and stereoscopic observation of fluoroscopic images.
1987-03-01
A study of reconstruction algorithms and filters for an industrial X-ray tomography system
Energy Technology Data Exchange (ETDEWEB)
Computed tomography (CT) has been incorporated in an industrial Diode-Array Digital Radiography (DADR) system. An input data size of 512 pixel points x 400 projections yielded a 400x400 output image matrix. Reconstruction algorithms used are the filtered backprojection (FBP) and the direct Fourier reconstruction (DFR). Various filters were used in the FBP reconstruction process and their effects on image quality were evaluated. A spatial resolution of 100 {mu}m was measured with a block of plates and a minimum detectable feature size in the range of 10-100 {mu}m was measured using thin wires. Industrial specimens imaged have included ceramic samples, ball bearings and integrated circuits. A number of engineering problems have been solved, such as adjustment of the X-ray source, centering of the rotator spindle in the view field and beam-hardening corrections. (orig.).
1990-12-20
Energy Technology Data Exchange (ETDEWEB)
Automatic segmentation of anatomical structures in medical images is a valuable tool for efficient computer-aided radiotherapy and surgery planning and an enabling technology for dynamic adaptive radiotherapy. This paper presents the design, algorithms and validation of new software for the automatic segmentation of CT images used for radiotherapy treatment planning. A coarse to fine approach is followed that consists of presegmentation, anatomic orientation and structure segmentation. No user input or a priori information about the image content is required. In presegmentation, the body outline, the bones and lung equivalent tissue are detected. Anatomic orientation recognizes the patient's position, orientation and gender and creates an elastic mapping of the slice positions to a reference scale. Structure segmentation is divided into localization, outlining and refinement, performed by procedures with implicit ...
2008-03-21
Disk's Spiral Arms Point to Possible Planets
National Aeronautics and Space Administration (NASA)
Simulations of young stellar systems suggest that planets embedded in a circumstellar disk can produce many distinctive structures, including rings, gaps and spiral arms. This video compares computer simulations of hypothetical systems to an image of system SAO 206462 taken by the Subaru Telescope and its HiCIAO instrument. n nCredit: NASA Goddard Space Flight Center/NCSA
2011-10-18
Lung dose calculations at kilovoltage x-ray energies using a model-based treatment planning system
International Nuclear Information System (INIS)
The determination of the dose to organs from diagnostic x rays has become important because of reports of radiation injury to patients from fluoroscopically guided interventional procedures. We have modified a convolution/superposition-based treatment planning system to compute the dose distribution for kilovoltage beams. We computed lung doses using this system and compared them to those calculated using the CDI3 organ dose calculation program. We also computed average lung doses from a simulated radiofrequency ablation procedure and compared our results to published doses for a similar procedure. Doses calculated using this system were an average of 20% lower for AP beams and 7% higher for PA beams than those obtained using CDI3. The ratio of the average dose to the lungs to the skin dose from the simulated ablation procedure ranged from 25% higher to 15% lower than that determined by other authors. Our results show that ...
2001-02-01
The petroleum industry is increasing its focus on the exploration of reservoirs in turbidite systems. However, these sedimentary environments are often characterized by very complex sand distributions. Hence, reservoir description based on conventional seismic and well-log interpretation may be very uncertain. There is a need to employ more quantitative seismic techniques to reveal reservoirs units in these complex systems from seismic amplitude data. In this study we focus on North Sea turbidite systems. Our goal is to improve the ability to use 3D seismic data to map reservoirs in these systems. A cross-disciplinary methodology for seismic reservoir characterization is presented that combines rock physics, sedimentology, and statistical techniques. We apply this methodology to two turbidite systems of Paleocene age located in the South ...
2000-01-01
System suitable for use in neutron radiography
Energy Technology Data Exchange (ETDEWEB)
A system for real-time neutron radiography of moving objects is described. It comprise a source adapted to generate a continuous uninterrupted series of neutron pulses. Each pulse has a predetermined peak power and duration compatible with the framing times of a real-time video imaging system. A transporter moves an object to be examined to bring sequentially position selected portions of the object in the path of the pulses. Where the object itself has moving components, pulses are sequentially incident on the object. According to any dissimilarities, the object will alter the intensity of the neutrons passing therethrough. In order to record separately the changes in the neutron intensity, for each pulse, an imager is positioned to receive the neutron beam pulses which have been altered by their passage through the object and produce images indicating intensity alterations. A ...
1990-02-07
System suitable for use in neutron radiography
International Nuclear Information System (INIS)
A system for real-time neutron radiography of moving objects is described. It comprise a source adapted to generate a continuous uninterrupted series of neutron pulses. Each pulse has a predetermined peak power and duration compatible with the framing times of a real-time video imaging system. A transporter moves an object to be examined to bring sequentially position selected portions of the object in the path of the pulses. Where the object itself has moving components, pulses are sequentially incident on the object. According to any dissimilarities, the object will alter the intensity of the neutrons passing therethrough. In order to record separately the changes in the neutron intensity, for each pulse, an imager is positioned to receive the neutron beam pulses which have been altered by their passage through the object and produce images indicating intensity alterations. A ...
1988-07-20
Neutron radiography with the cyclotron, 4
International Nuclear Information System (INIS)
A real-time neutron radiography system was installed at the neutron radiography facility of Sumitomo Heavy Industries where a sub-compact cyclotron is used as a neutron generator and nominal neutron flux was observed as 1.1 x 10"6 n/cm"2/sec. Preliminary tests were made for various kinds of such components as collimators, scintillators, cameras and lenses and the system was chosen to give the highest quality images. Especially for the scintillator screen, screening tests were carried out for compounds of LiF/ZnS(Ag) and Gd_2O_3/ZnS(Ag) by radiographic film method. The neutron radiography image was converted to fluorescent images by means of the converter and observed by a SIT type TV camera. The video signal was directly displayed on a CRT or after processed with digital image processing devices. The characteristics of this system as for the ...
1986-01-01
Computed radiography for major airway in pediatrics
International Nuclear Information System (INIS)
This paper shows the efficacy of computed radiography for major airway in pediatrics. For this purpose, we examined 40 children (range 2 weeks to 14 years; mean 2.3 years) using Fuji Computed Radiography (FCR) and radiation dose using pediatric phantom under FCR and conventional film and screen system. In comparison study with FCR and conventional film and screen system, FCR images are superior to conventional system in all cases. Scorings were done for the quality of the image of the pharynx, the trachea, and both main bronchi. In phantom study to check radiation dose, radiation dose could be reduced 1/6 of the value using high speed film and screen and 1/15 of the value using conventional speed film and screen. FCR also showed clear airway images in all cases but technical failure to evaluate the clinical lesion. These results suggest that FCR is the adequate ...
1986-01-01
The denoising of Monte Carlo dose distributions using convolution superposition calculations
International Nuclear Information System (INIS)
Monte Carlo (MC) dose calculations can be accurate but are also computationally intensive. In contrast, convolution superposition (CS) offers faster and smoother results but by making approximations. We investigated MC denoising techniques, which use available convolution superposition results and new noise filtering methods to guide and accelerate MC calculations. Two main approaches were developed to combine CS information with MC denoising. In the first approach, the denoising result is iteratively updated by adding the denoised residual difference between the result and the MC image. Multi-scale methods were used (wavelets or contourlets) for denoising the residual. The iterations are initialized by the CS data. In the second approach, we used a frequency splitting technique by quadrature filtering to combine low frequency components derived from MC simulations with high frequency components derived from CS components. The rationale is to take the scattering ...
2007-09-07
Seafloor mapping and morphometric analysis of landslide scars can provide useful insights for marine geo-hazard assessment, as demonstrated by several studies performed on different geological settings. The availability of high-resolution multibeam bathymetry and long-range side scan sonar data on the submarine portions of Stromboli Volcano allow us to map and characterize the main mass-wasting features that affect, on the whole, about the 90% of its submarine extension. In particular, two main kinds of tsunamigenic landslides have been recognized and analyzed. Large-scale sector collapses (Fig. 1) are catastrophic events that mobilize 1-2 cubic kilometers of material, generating huge tsunami waves that may affect Stromboli and propagate in surrounding areas; related hazard is not very high, as they show recurrence periods of some (or more) thousand years. Conversely, medium-scale landslides are more hazardous, as they occur at higher frequency with respect to the previous events, i.e. ...
2010-12-01
Experience and recent developments in nuclear forensics at the Institute of Isotopes
International Nuclear Information System (INIS)
Full text: Based on experience with nuclear material confiscated in Hungary from illicit trafficking activities in the nineties it has been decided that traditional gamma-spectrometry should be complemented by destructive analytical techniques. The 17/1996 (I. 31.) Korm. Governmental Decree delegated the identification, categorization and characterization tasks to the Institute of Isotopes, Budapest. Routine gamma-spectrometric methods have been further developed aiming at the i) age (production date) determination of seized samples and complete (nondismountable) uranium-bearing items (such as fresh fuel bundles and fission chambers) by HRGS technique, ii) improvement of measurement accuracy and reliability. Starting in 2005 mass spectrometry (ICP-SFMS) and scanning electron microscopy have been implemented to characterize nuclear samples in more detail and to analyze environmental samples both for isotopic and elemental composition focusing on long-lived radioactive isotopes including ...
Developmental cortical thinning in fetal alcohol spectrum disorders.
Regional cortical thickness was evaluated using CIVET processing of 3D T1-weighted images (i) to compare the variation in cortical thickness between 33 participants with fetal alcohol spectrum disorders (FASD) aged 6-30 years (mean age 12.3 years) versus 33 age/sex/hand-matched controls, and (ii) to examine developmental changes in cortical thickness with age from children to young adults in both groups. Significant cortical thinning was found in the participants with FASD in large areas of the bilateral middle frontal lobe, pre- and post- central areas, lateral and inferior temporal and occipital lobes compared to controls. No significant cortical thickness increases were observed for the FASD group. Cortical thinning with age in a linear model was observed in both groups, but the locations were different for each group. FASD participants showed thinning with age in the left middle frontal, bilateral precentral, bilateral ...
2011-06-17
International Nuclear Information System (INIS)
Numerous mercury intrusion porosimetry (MIP) studies have been carried out to investigate the pore structure in cement-based materials. However, the standard MIP often results in an underestimation of large pores and an overestimation of small pores because of its intrinsic limitation. In this paper, an innovative MIP method is developed in order to provide a more accurate estimation of pore size distribution. The new MIP measurements are conducted following a unique mercury intrusion procedure, in which the applied pressure is increased from the minimum to the maximum by repeating pressurization-depressurization cycles instead of a continuous pressurization followed by a continuous depressurization. Accordingly, this method is called pressurization-depressurization cycling MIP (PDC-MIP). By following the PDC-MIP testing sequence, the volumes of the throat pores and the corresponding ink-bottle pores can be determined at every pore size. These values are used to calculate pore size ...
2010-07-01
Basic study of entire whole-body PET scanners based on the OpenPET geometry
International Nuclear Information System (INIS)
A conventional PET scanner has a 15-25 cm axial field-of-view (FOV) and images a whole body using about six bed positions. An OpenPET geometry can extend the axial FOV with a limited number of detectors. The entire whole-body PET scanner must be able to process a large amount of data effectively. In this work, we study feasibility of the fully 3D entire whole-body PET scanner using the GATE simulation. The OpenPET has 12 block detector rings with the ring diameter of 840 mm and each block detector ring consists of 48 depth-of-interaction (DOI) detectors. The OpenPET has the axial length of 895.95 mm with five parts of 58.95 mm open gaps. The OpenPET has higher single data loss than a conventional PET scanner at grouping circuits. NECR of the OpenPET decreases by single data loss. But single data loss is mitigated by separating the axially arranged detector into two parts. Also, multiple coincidences are found to be ...
2010-09-01
Topological excitations and second order transitions in 3D O(N) models
Energy Technology Data Exchange (ETDEWEB)
I discuss several examples of critical phenomena in O(N) models where topological excitations play an important role at criticality. I focus particular attention on the O(2) model in 3D, where recent measurements of the vortex string length distribution in equilibrium suggest the existence of a quantitative picture of the critical behavior in terms of defects. The compatibility of this perspective with renormalization group predictions is examined.
2001-01-01
T-HEMP3D, 3-D Time-Dependent Elastic Plastic Flow
International Nuclear Information System (INIS)
1 - Description of program or function: T-HEMP3D (Transportable HEMP3D) is a derivative of the STEALTH three-dimensional thermodynamics code developed by Science Applications, Inc. Changes were made primarily in three areas: material specification, coordinate generation, and the addition of sliding surface boundary conditions. STEALTH itself is based entirely on the HEMP3D code written at LLNL. HEMP3D solves problems in solid mechanics involving dynamic plasticity and time-dependent material behavior and problems in gas dynamics. 2 - Method of solution: The equations of motion, conservation equations, and constitutive relations for stresses, strains, hydrostatic pressure, the von Mises yield condition, and artificial viscosity are solved by finite difference methods following the format of the HEMP code (NESC Abstract ...
UK PubMed Central (United Kingdom)
The non-natural pyrido[2,3-d]pyrimidine nucleoside F, which pairs preferentially with guanine (G) and adenine (A) within double-helical DNA, recognizes with high selectivity AT base pairs within triple-helical...Full Text Available
1994-07-11
Pd-Na/F double exploding foil photoionization experiment
The achievement of inner-shell photoionization of Zn-like Pd by means of two exploding foils is described. This resulted in the soft X-ray transition 3d94s2-3d104p at 46 A. It is shown that the photoionization of inner shell electrons in highly stripped ions can lead to X-ray transitions which may be candidates for X-ray lasers under 50 A.
1990-03-01
On the Metastable Level in Ni-like Ions
Energy Technology Data Exchange (ETDEWEB)
The lowest excited level in Ni-like ions, 3d{sup 9}4s {sup 3}D{sub 3}, decays only via a magnetic octupole (M3) decay. They present calculated values of transition wavelengths and rates for ions with 30 {le} Z {le} 100. They have observed this line in Xe{sup 26+}, using the Livermore EBIT-I electron beam ion trap and a microcalorimeter, as well as a high-resolution flat-field grating spectrometer.
2004-09-14
International Nuclear Information System (INIS)
Our studies on K#beta#/K#alpha# X-ray intensity ratios of some of the technologically important 3d-transition metal compounds have been reviewed. Comparison of the experimental results with single-configuration Dirac-Fock calculations provided important information on the valence states of the transition metals in various compounds, which can be helpful in understanding the nature of bonding in the compounds. (author)
2000-02-01
Chemical sensitivity of the Ksub(. beta. )/Ksub(. cap alpha. ) x-ray intensity ratio for 3d elements
Energy Technology Data Exchange (ETDEWEB)
Chemical influences on the relative Ksub(..beta..)/Ksub(..cap alpha..) x-ray intensity ratio up to five per cent were found for different chemical constitutions of Cr, Mn, Fe and Cu by very precise PIXE measurements. In the discussion of these effects, screening of 3p electrons by a varying 3d valence charge, as well as polarizational effects are of importance.
1982-12-28
Chemical sensitivity of the Ksub(#nu#)/Ksub(#alpha#) x-ray intensity ratio for 3d elements
International Nuclear Information System (INIS)
Chemical influences on the relative Ksub(#nu#)/Ksub(#alpha#) x-ray intensity ratio up to five per cent were found for different chemical constitutions of Cr, Mn, Fe and Cu by very precise PIXE measurements. In the discussion of these effects, screening of 3p electrons by a varying 3d valence charge, as well as polarisational effects are of importance. (author).
1982-12-01
A 3D tomographic EBSD analysis of a CVD diamond thin film
Energy Technology Data Exchange (ETDEWEB)
We have studied the nucleation and growth processes in a chemical vapor deposition (CVD) diamond film using a tomographic electron backscattering diffraction method (3D EBSD). The approach is based on the combination of a focused ion beam (FIB) unit for serial sectioning in conjunction with high-resolution EBSD. Individual diamond grains were investigated in 3-dimensions particularly with regard to the role of twinning.
2008-09-15
Electronic imaging system for neutron radiography at a low power research reactor
Energy Technology Data Exchange (ETDEWEB)
This paper describes an electronic imaging system for producing real time neutron radiography from a low power research reactor, which will allow inspections of samples with high efficiency, in terms of measuring time and result analysis. This system has been implanted because of its potential use in various scientific and industrial areas where neutron radiography with photographic film could not be applied. This real time system is installed in neutron radiography facility of Argonauta nuclear research reactor, at the Instituto de Engenharia Nuclear of the Comissao Nacional de Energia Nuclear, in Brazil. It is adequate to perform real time neutron radiography of static and dynamic events of samples.
2010-08-15
Electronic imaging system for neutron radiography at a low power research reactor
International Nuclear Information System (INIS)
This paper describes an electronic imaging system for producing real time neutron radiography from a low power research reactor, which will allow inspections of samples with high efficiency, in terms of measuring time and result analysis. This system has been implanted because of its potential use in various scientific and industrial areas where neutron radiography with photographic film could not be applied. This real time system is installed in neutron radiography facility of Argonauta nuclear research reactor, at the Instituto de Engenharia Nuclear of the Comissao Nacional de Energia Nuclear, in Brazil. It is adequate to perform real time neutron radiography of static and dynamic events of samples.
2010-08-01
Energy Technology Data Exchange (ETDEWEB)
Introduction: The goal of this study was to compare contrast-enhanced T1-weighted Flash and Turbo-Flash sequences with conventional spin-echo sequences as a basis for planning high-precision radiotherapy. Methods: A total of 25 consecutive patients with different intracranial tumors and a disrupted blood-brain barrier were studied. T1-weighted Flash, Turbo-Flash and conventional spin-echo images were evaluated after controlled 30-s infusion of 0.1 mmol/kg body weight of Gd-DTPA. The evaluation of the three sequences included the measurement of the signal- and contrast-to-noise ratios, the visual inspection of the tumors and artifacts, and the measurement of tumor size. Results: The signal- and contrast-to-noise ratios were significantly (P<0.05-0.01) lower for Flash and Turbo-Flash than for conventional spin-echo sequences. However, visual inspection of the contrast-enhancing tumors revealed in 23 and 24 of 25 lesions of Flash and Turbo-Flash ...
1997-03-01
Energy Technology Data Exchange (ETDEWEB)
Much of the current technology on 3D-prestack depth migration is based on the Kirchhoff method and the traveltime information needed for this purpose is obtained by the ray-theory approximation. The main motivation driving these options is to reduce computations but it can also have an adverse effect on the quality of results. Experience with real data indicates that the corresponding poststack data migrated by the reverse-time method often yields superior results. Considerable computational efficiency can be obtained by employing nonuniform coarse grid spacing during the reverse-time migration. We followed this strategy for developing a parallel scheme for doing 3D- prestack depth migration. However, we worked only on a small subset of shot gathers whose determined by the Quasi-Monte Carlo method. The results were indistinguishable from those obtained by using a much larger population of uniformly ...
1997-07-01
Ultra high field magnetic resonance imaging
International Nuclear Information System (INIS)
Understanding human brain function, brain development and brain dysfunction is one of the great challenges of the twenty first century. Biomedical imaging has now run up against a number of technical constraints that are exposing limits to its potential. In order to overcome the current limits to high-field magnetic resonance cerebral imaging (MRI) and unleash its fullest potential, the Cea has built NeuroSpin, an ultra-high-field neuroimaging facility at its Saclay centre (in the Essonne). NeuroSpin already boasts three fully operational MRI systems. The first is a 3-tesla high-field system and the second is a very-high-field 7-tesla system, both of which are dedicated to clinical studies and investigations in humans, while the third is an ultra-high-field 17.65-tesla system designed for studies on small animals. In 2011, NeuroSpin will be commissioning an ...
Application of distributed and parallel technology in nuclear power plant engineering simulator
International Nuclear Information System (INIS)
A nuclear power plant engineering (NPP) simulator may include many system functions such as thermal-hydraulic calculation, 3D reactor neutron kinetics model, control and protection system, display and operational human-machine interface, intelligent alarm system, etc. If all those functions are simulated using a single code, the size of the program will cause structural or managerial problems, and the hardware requirement could be tremendous. Thus, any local function errors or changes may affect the whole code, which will make development and maintenance extremely costly. So the nondistributed code is not considered to be flexible and feasible. Currently, distributed and parallel technologies have been applied to develop NPPs engineering simulator for safety analysis, verification of advanced main control room display, operation and intelligent alarm design. The distributed ...
Fuji computed radiography (FCR) for the diagnosis of spinal disorders
International Nuclear Information System (INIS)
Since April, 1985, we have, in co-operation with the Fuji Film Co., Ltd., used Fuji Computed Radiography (FCR) in the diagnosis of spinal disorders. FCR is a new computed radiographic system which uses an energy-storage phosphorus panel called an ''Imaging Plate'' as an image sensor. The ''Imaging Plate'' can be used to obtain radiographs in exactly the same way as the screen-film combination used in conventional radiography; X-rays are exposed on the ''Imaging Plate'' instead of X-ray film in the conventional fashion, and then the ''Imaging Plate'' is calculated. The processed digital data from the scans is transformed into a picture by means of digital-to-analogue conversion. The pictures are always clear and beautiful. Plain films of the spine taken by FCR are even clearer, even in the cervicothoracic region, where it is usually difficult to obtain clear ...
1987-01-01
Assessment of the effects of pixel loss on image quality in direct digital radiography
Energy Technology Data Exchange (ETDEWEB)
Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitative image quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line pairs phantom were found to be more ...
2004-03-21
Assessment of the effects of pixel loss on image quality in direct digital radiography
International Nuclear Information System (INIS)
Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitative image quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line pairs phantom were found to be more sensitive to pixel loss. Measurement of the ...
2004-03-21
International Nuclear Information System (INIS)
Neutron radiography and neutron radioscopy are rapidly becoming the valuable tools for nondestructive testing and basic research. The Phoenix Memorial Laboratory has developed a neutron facility capable of both film neutron radiography and real time neutron radioscopy, and has used this facility to study several phenomena of interest to the researchers in many areas. Neutrons can be used for imaging the phenomena that X-ray cannot image, such as the presence, absence or movement of hydrogenous materials inside metals such as aluminum or steel. There are three basic methods for obtaining images using neutrons: high resolution film neutron radiography, real-time neutron radioscopy and transfer film neutron radiography. The neutron radiography facility at Phoenix Memorial Laboratory, the neutron radioscopic imaging systems, the neutron radiographic detectors, lubrication studies, spray ...
1992-03-01
A novel approach to personal photo album representation and management
In this paper we present a novel approach to personal photo album management allowing the end user to efficiently access the collection without any need for tedious manual annotation or indexing of the photos. The proposed work exploits methods and technology from the field of computer vision and pattern recognition for face detection, face representation and image annotation to automatically create description of images useful for content-based searching and retrieval. In fact, even if most of the used techniques are not reliable enough to address the general problem of content-based image retrieval, we show that, in a limited domain such as the one of personal photo album, it is possible to obtain results that improve the browsing capabilities of current photo album management systems. In particular, starting from the observation that most personal photos depict a usually small number of people in a ...
2008-01-01
International Nuclear Information System (INIS)
The objective of this study was to explore the role of three-dimensional (3-D) rotational angiography (RA) of the inferior vena cava (IVC; 3-D CV) before filter retrieval and its impact on treatment planning compared with standard anteroposterior cavography (sCV). Thirty patients underwent sCV and 3-D CV before IVC filter retrieval. Parameters assessed were: projection of filter arms or legs beyond the caval lumen, thrombus burden within the filter and IVC, and orientation of the filter within IVC. Skin and effective radiation doses were calculated. Statistical analysis was performed using paired Student t test and nonparametric McNemar's test. Standard anteroposterior cavography detected 49 filter arms or legs projecting beyond the caval lumen in 25 patients. Three-dimensional CV demonstrated 89 filter arms or legs projecting beyond the caval lumen in 28 ...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver ...
2003-03-15
International Nuclear Information System (INIS)
The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver ...
2003-03-01
Low resolution and un-sharp facial images are always captured from surveillance videos because of long human-camera distance and human movements. Previous works addressed this problem by using an active camera to capture close-up facial images without considering human movements and mechanical delays of the active camera. In this paper, we proposed a unified framework to capture facial images in video surveillance systems by using one static and active camera in a cooperative manner. Human faces are first located by a skin-color based real-time face detection algorithm. A stereo camera model is also employed to approximate human face location and his/her velocity with respect to the active camera. Given the mechanical delays of the active camera, the position of a target face with a given delay can be estimated using a Human-Camera Synchronization Model. By controlling the active camera with ...
2008-04-01
Energy Technology Data Exchange (ETDEWEB)
Purpose: The purpose of this study was to observe the process of fixation in liver specimens non-invasively by means of magnetic resonance. The fixation process of several formaldehyde-containing solutions was monitored with MRI and MRS at two different temperatures. Materials and Methods: Liver specimens were conserved in aqueous fixative solutions containing formaldehyde concentrations of 0.7, 1.8, 4 and 7.2% and at different temperatures of 5 C and 20 C. MRI was performed with T1-, T2- and PD-weighted TSE sequences, a 2D FLASH-sequence with and without magnetization transfer, and a FISP 3D-sequence on a clinical 1.5 Tesla MR whole-body unit, and MRS with {sup 1}H-spectroscopic methods (STEAM-sequence) on a 3 Tesla MR whole-body unit. Results: The diffusion of formaldehyde into the tissue was best identified on PD- and T1-weighted images as a band under the liver surface with increasing thickness, penetrating especially ...
2004-04-01
Magnetic resonance imaging. Handbook and atlas; Kernspintomographie. Kompendium und Atlas
Energy Technology Data Exchange (ETDEWEB)
Magnetic resonance imaging (MRI) as a diagnostic imaging tool relies on the generation of magnetic fields, whereas the computerized tomography (CT) uses X-radiation. The fundamental principle of MRI is the magnetic resonance of paramagnetic atomic nuclei. These nuclei, as e.g. protons (= hydrogen nuclei), are aligned in required orientation by application of a strong magnetic field. Upon simultaneous application of an electromagnetic high-frequency field perpendicular to the axis of the basic magnetic field, and in response to periodical changing of the electromagnetic field at a given frequency, the originally aligned paramagnetic nuclei are forced into a movement similar to that of a ``whipping top``. When the resonance frequency is shut off, the nuclei return to their former, aligned positions, inducing a weak signal in a coil. The series of signals generated by multiple repetition of this process of excitation of nuclei and their return to ...
1999-10-01
Experience in using Fuji computed radiography (FCR), 1
Energy Technology Data Exchange (ETDEWEB)
New experiment of radiography in using Fuji Intelligent Diagnostic X-ray System was first reported in XV International Congress of Radiology, 1981. By utilizing this system instead of traditional screen/film system, high density imaging plate in conjunction with computed image processor was developed, this is FCR. However, as the numerous problems in regard to the basic side of FCR system are found, it is expected that these are solved by investigators at their earliest opportunities. The purpose of this study is to reduce the radiation doses of the patients at radiography of the chest by using FCR system installed in our Department of Radiology in July, 1984. Experimentally we measured the radiation doses of the patient having the each breast of 18, 20, 22 and 24cm in thickness at radiography of the chest by using VICTOREEN MODEL 666 survey ...
1984-12-01
Experience in using Fuji computed radiography (FCR), 1
International Nuclear Information System (INIS)
New experiment of radiography in using Fuji Intelligent Diagnostic X-ray System was first reported in XV International Congress of Radiology, 1981. By utilizing this system instead of traditional screen/film system, high density imaging plate in conjunction with computed image processor was developed, this is FCR. However, as the numerous problems in regard to the basic side of FCR system are found, it is expected that these are solved by investigators at their earliest opportunities. The purpose of this study is to reduce the radiation doses of the patients at radiography of the chest by using FCR system installed in our Department of Radiology in July, 1984. Experimentally we measured the radiation doses of the patient having the each breast of 18, 20, 22 and 24cm in thickness at radiography of the chest by using VICTOREEN MODEL 666 survey ...
1984-01-01
Keck Diffraction-Limited Imaging of the Young Quadruple Star System HD 98800
This paper presents diffraction-limited 1-18 micron images of the young quadruple star system HD 98800 obtained with the W. M. Keck 10-m telescopes using speckle and adaptive optics imaging at near-IR wavelengths and direct imaging at mid-IR wavelengths. The two components of the visual binary, A and B, both themselves spectroscopic binaries, were separable at all wavelengths, allowing us to determine their stellar and circumstellar properties. Combining these observations with spectroscopic data from the literature, we derive an age of 10 Myr, masses of 0.93 and 0.64 M_sun and an inclination angle of 58 deg for the spectroscopic components of HD 98800 B, and an age of 10 Myr and a mass of 1.1 M_sun for HD 98800 Aa. Our data confirm that the large mid-IR excess is entirely associated with HD 98800 B. This excess exhibits a black body temperature of 150 K and a strong 10 micron silicate emission feature. ...
2001-01-01
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study is to investigate the feasibility of visualization and void fraction measurement of air-water two-phase flow in a small diameter tube (I.D.: 4.08 mm) by using the real-time neutron radiography and image processing techniques. Video images of two-phase flow were taken by using the real-time neutron radiography system (thermal neutron radiography facility No.2) installed at the Japan Research Reactor 3M of the Japan Atomic Energy Research Institute. The shape of bubbles and its moving behavior were clearly observed from the video images. The image corrections for dark current, shading, field intensity fluctuation and electrical system drift were examined in order to measure the void fraction from the video images. Though, generally speaking, the effect of the scattered neutron could not be ignored for quantification ...
1993-06-01
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study is to investigate the feasibility of visualization and void fraction measurement of air-water two-phase flow in a small diameter tube (inner diameter; 4.08mm) by using the real-time neutron radiography and image processing techniques. Video images of two-phase flow were taken by using the real-time neutron radiography system (thermal neutron radiography facility No.2) installed at the Japan Research Reactor 3 M of the Japan Atomic Energy Research Institute. The shape of bubbles and its moving behavior were clearly observed from the video images. The image corrections for dark current, shading, field intensity fluctuation and electrical system drift were examined in order to measure the void fraction from the video images. Though, generally speaking, the effect of the scattered neutron could not be ignored for ...
1994-07-01
International Nuclear Information System (INIS)
The purpose of this study is to investigate the feasibility of visualization and void fraction measurement of air-water two-phase flow in a small diameter tube (I.D.: 4.08 mm) by using the real-time neutron radiography and image processing techniques. Video images of two-phase flow were taken by using the real-time neutron radiography system (thermal neutron radiography facility No.2) installed at the Japan Research Reactor 3M of the Japan Atomic Energy Research Institute. The shape of bubbles and its moving behavior were clearly observed from the video images. The image corrections for dark current, shading, field intensity fluctuation and electrical system drift were examined in order to measure the void fraction from the video images. Though, generally speaking, the effect of the scattered neutron could not be ignored for quantification ...
1993-01-01
Crystal field analysis of the energy level structure of Cs{sub 2}NaAlF{sub 6}:Cr{sup 3+}
Energy Technology Data Exchange (ETDEWEB)
An analysis of the energy level structure of Cr{sup 3+} ions in Cs{sub 2}NaAlF{sub 6} crystal is performed using the exchange charge model (ECM) together with the crystal field analysis/microscopic spin Hamiltonian (CFA/MSH) computer package. Utilizing the crystal structure data, our approach enables modelling of the crystal field parameters (CFPs) and thus the energy level structure for Cr{sup 3+} ions at the two crystallographically inequivalent sites in Cs{sub 2}NaAlF{sub 6}. Using the ECM initial adjustment procedure, the CFPs are calculated in the crystallographic axis system centred at the Cr{sup 3+} ion at each site. Additionally the CFPs are also calculated using the superposition model (SPM). The ECM and SPM predicted CFP values match very well. Consideration of the symmetry aspects for the so-obtained CFP datasets reveals that the latter axis system matches the symmetry-adapted axis system related directly to the ...
2006-06-07
Crystal field analysis of the energy level structure of Cs2NaAlF6:Cr3+
International Nuclear Information System (INIS)
An analysis of the energy level structure of Cr3+ ions in Cs2NaAlF6 crystal is performed using the exchange charge model (ECM) together with the crystal field analysis/microscopic spin Hamiltonian (CFA/MSH) computer package. Utilizing the crystal structure data, our approach enables modelling of the crystal field parameters (CFPs) and thus the energy level structure for Cr3+ ions at the two crystallographically inequivalent sites in Cs2NaAlF6. Using the ECM initial adjustment procedure, the CFPs are calculated in the crystallographic axis system centred at the Cr3+ ion at each site. Additionally the CFPs are also calculated using the superposition model (SPM). The ECM and SPM predicted CFP values match very well. Consideration of the symmetry aspects for the so-obtained CFP datasets reveals that the latter axis system matches the symmetry-adapted axis system related directly to the six Cr-F bonds well. Using the ECM ...
2006-06-07
Energy Technology Data Exchange (ETDEWEB)
The determination of optical parameter type in x-ray pelvimetry was performed on 59 subjects using Fuji computed radiography (FCR). Excellent measurable images were obtained at GT (type A), RT (type P), GA (1.6) and RN (2.0). To reduce maternal and fetal exposure to radiation, the doses were progressively decreased to 50%, 25%, 12.5%, 6.3%, that of conventional screen/film system. One-eighth per cent of conventional radiation dose was minimum for FCR at which measurable images could be obtained. Thereby drastically reducing the radiological exposure to both mother and fetus was possible to obtain measurable images in FCR. (author).
1991-05-01
International Nuclear Information System (INIS)
The determination of optical parameter type in x-ray pelvimetry was performed on 59 subjects using Fuji computed radiography (FCR). Excellent measurable images were obtained at GT (type A), RT (type P), GA (1.6) and RN (2.0). To reduce maternal and fetal exposure to radiation, the doses were progressively decreased to 50%, 25%, 12.5%, 6.3%, that of conventional screen/film system. One-eighth per cent of conventional radiation dose was minimum for FCR at which measurable images could be obtained. Thereby drastically reducing the radiological exposure to both mother and fetus was possible to obtain measurable images in FCR. (author).
1991-01-01
British Library Electronic Table of Contents (United Kingdom)
Introduction.Microfluidic technology allows fast reactions in a simple experimental setup, while using very low volumes and amounts of starting material. Consequently, microfluidic technology is an ideal tool for radiolabeling reactions involving short-lived positron emitters. Optimization of the complex array of different reaction conditions requires knowledge of the different reaction parameters linked to the microfluidic system as well as their influence on the radiochemical yields. 1-(5-Deoxy-5-fluoro-?-d-arabinofuranosyl)-2-nitroimidazole ([18F]FAZA) is a frequently used radiotracer for PET imaging of tumor hypoxia. The present study describes the radiosynthesis of [18F]FAZA by means of microfluidic technology and subsequent small animal PET imaging in EMT-6 tumor-bearing mice.Methods...
2011-01-01
New thermal neutron imaging facility at the University of Texas reactor
Energy Technology Data Exchange (ETDEWEB)
A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed at the University of Texas TRIGA reactor. Extensive Monte Carlo design calculations were used to determine optimal design parameters of the neutron collimator system to avoid costly trial and error. Thermal neutron flux determined by gold foil activation is 5 {times} 10{sup 6} n/cm{sup 2}{center_dot}s at the primary imaging location with beam size of 22.5 cm in diameter. The collimation ratio can be varied from 125 to 235. The neutron-to-gamma ratio is 7.8 {times} 10{sup 6} n/cm{sup 2}{center_dot}mR. The facility has been tested for radiography and tomography applications and is now fully operational.
1999-09-01
Intracranial Dural Metastasis of Ewing's Sarcoma: a Case Report
International Nuclear Information System (INIS)
Ewing's sarcoma is a malignant bone tumor that can occur anywhere in the body, but it is most commonly observed in the long bones of the arms and legs, the pelvis and in the chest. The predominant sites of metastasis include the lung (38%), bone (including the spine; 31%), and the bone marrow (11%). Metastasis of Ewing's sarcoma to the central nervous system (CNS) is relatively rare, and most of the previous reports have demonstrated involvement of the bony calvarium or brain parenchyma. We describe here the imaging findings of dural metastasis of Ewing's sarcoma, and these imaging findings have not been previously reported on in the medical literature. In conclusion, dural metastasis of Ewing's sarcoma is very rare and its imaging characteristics are similar to those of a primary tumor, which mimic the findings of a schwannoma or meningioma. Despite its rarity, secondary Ewing's sarcoma may be included ...
2008-02-01
Fetal magnetic resonance imaging of the brain: technical considerations and normal brain development
International Nuclear Information System (INIS)
Fetal MRI examines non-invasively the unborn fetus. Ultrafast MRI sequences effectively suppress fetal motion. Multiple case reports and studies have shown that fetal MRI is particularly helpful in the evaluation of the central nervous system. The high contrast-to-noise ratio, the high spatial resolution, the multiplanar capabilities, the large field of view and the simultaneous visualisation of fetal and maternal structures have proven to be advantageous. Fetal MRI is particularly helpful in the evaluation of the normal and pathological development of the brain. Despite the fact that no side effects have been reported or are to be expected, the use of MRI during pregnancy is still limited to the second and third trimester of pregnancy. Magnetic resonance imaging contrast media are not to be used as it passes the placenta. Ultrasound remains the primary screening modality for fetal pathology; fetal MRI can serve as an adjunct or second-line ...
2002-08-01
Dynamic and static error analyses of neutron radiography testing
Energy Technology Data Exchange (ETDEWEB)
Neutron radiography systems are being used for real-time visualization of the dynamic behavior as well as time-averaged measurements of spatial vapor fraction distributions for two phase fluids. The data in the form of video images are typically recorded on videotape at 30 frames per second. Image analysis of he video pictures is used to extract time-dependent or time-averaged data. The determination of the average vapor fraction requires averaging of the logarithm of time-dependent intensity measurements of the neutron beam (gray scale distribution of the image) that passes through the fluid. This could be significantly different than averaging the intensity of the transmitted beam and then taking the logarithm of that term. This difference is termed the dynamic error (error in the time-averaged vapor fractions due to the inherent time-dependence of the measured data) and is separate from the static ...
1999-03-01
Quantitative density measurements from a real-time neutron radiography system
Energy Technology Data Exchange (ETDEWEB)
An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation.
1986-01-01
Quantitative density measurements from a real-time neutron radiography system
International Nuclear Information System (INIS)
An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation.
1986-11-16
Nuclear fuel assembly identification using computer vision
This report describes an improved method of remotely identifying irradiated nuclear fuel assemblies. The method uses existing in-cell TV cameras to input an image of the notch-coded top of the fuel assemblies into a computer vision system, which then produces the identifying number for that assembly. This system replaces systems that use either a mechanical mechanism to feel the notches or use human operators to locate notches visually. The system was developed for identifying fuel assemblies from the Fast Flux Test Facility (FFTF) and the Clinch River Breeder Reactor, but could be used for other reactor assembly identification, as appropriate.
1985-11-01
Artificial intelligence: the future in nuclear plant maintenance
Energy Technology Data Exchange (ETDEWEB)
The role of robotics and remote handling equipment in future nuclear power plant maintenance activities is discussed in the context of artificial intelligence applications. Special requirements manipulators, control systems, and man-machine interfaces for nuclear applications are noted. Tasks might include inspection with cameras, eddy current probes, and leak detectors; the collection of material samples; radiation monitoring; and the disassembly, repair and reassembly of a variety of system components. A robot with vision and force sensing and an intelligent control system that can access a knowledge base is schematically described. Recent advances in image interpretation systems are also discussed.
1984-12-01
Artificial intelligence: the future in nuclear plant maintenance
International Nuclear Information System (INIS)
The role of robotics and remote handling equipment in future nuclear power plant maintenance activities is discussed in the context of artificial intelligence applications. Special requirements manipulators, control systems, and man-machine interfaces for nuclear applications are noted. Tasks might include inspection with cameras, eddy current probes, and leak detectors; the collection of material samples; radiation monitoring; and the disassembly, repair and reassembly of a variety of system components. A robot with vision and force sensing and an intelligent control system that can access a knowledge base is schematically described. Recent advances in image interpretation systems are also discussed.
1984-09-23
Real-time neutron radiography at the Iea-R1 m nuclear research reactor
International Nuclear Information System (INIS)
A LIXI (Light Intensifier X-ray Image) device has been employed in a real-time neutron radiography system. The LIXI is coupled to a video camera and the real-time images can be observed in a TV monitor, and processed in a computer. In order to get the real-time system operational, the neutron radiography facility installed at the IEA-R1 m nuclear research reactor of the IPEN-CNEN/S P has been optimized. The most important improvements were the neutron/gamma ratio, the effective energy of the neutron beam, decrease of the scattered radiation at the irradiation position, and the additional shielding of the video camera. Several one-frame as well as computer processed images are presented. The overall Modulation Transfer Function for the real-time system was obtained from the resolution parameter p = 0:44 +- 0:04 mm; the system sensitivity, ...
2003-06-01
Energy Technology Data Exchange (ETDEWEB)
Radiographic images generated by the real-time neutron radiography system (RTNR) are analyzed by customized image processing software of the determination of instantaneous void fraction distribution. The cross-sectional averaged axial void fraction profiles and the two-dimensional void fraction profiles are determined simultaneously for each image. Various flow regimes are generated to determine if the RTNR system can accurately predict the void distribution in the radial, axial, and temporal coordinates. The results show the RTNR system correctly determines the void fraction distribution for each flow regime; however, accuracy decreases with decreasing void fraction. For net water thicknesses > 1.0 cm, the accuracy decreases with increasing water thickness due to the extreme sensitivity of thermal neutron interactions with light water. Heavy water is a more ...
1995-01-01
Energy Technology Data Exchange (ETDEWEB)
A demonstration of the first mobile 'on-off' neutron radiography system, developed by Vought Corporation Advanced Technology Center, has been conducted at McClellan Air Force Base. On-site neutron radiography operations with the engineering model were carried out to demonstrate the potential of such a system for in situ detection of hidden moisture and corrosion in aircraft structures, and to assess the performance of the unique hardware system in a depot environment. Inspections were performed on F-111 and F-106 aircraft, and several structures removed from T-39 and A-10 aircraft were also inspected. The effectiveness of the new N-ray system for imaging moisture and corrosion was confirmed after subsequent removal of skins from some of the F-111 structures. Excellent correlation of radiographic images with actual moisture and corrosion damage ...
1983-01-01
Targeted drug delivery under MRI guidance
British Library Electronic Table of Contents (United Kingdom)
The main goal of local drug delivery is to increase the concentration of a specific therapeutic agent in a target tissue with minimal nontarget distribution. Compared to systemic therapy, local drug delivery provides a high level of therapeutic efficacy with minimal systemic effects. The current primary imaging modality for drug delivery has been x-ray angiography, but it has major limitations including anatomical ambiguity and inability to visualize the targeted tissues. Due to these inherent problems, MR guidance has been explored as an alternative imaging modality for guiding and monitoring of drug therapy. Recently, interventional MR (XMR) systems have been implemented that have both dual x-ray and MRI capabilities in a single suite and allow for real-time interventional procedures to ...
2008-01-01
Real-time imaging for neutron radiography at KURRI
International Nuclear Information System (INIS)
For neutron radiography (NR), photographic techniques have been mainly used for many years. To observe a dynamic event and to test many samples, the real-time neutron radiography (i.e. neutron television - NTV) system has been introduced at the E-2 experimental tube of the Kyoto University Research Reactor (KUR). The NTV system has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuel, to investigation of moving objects and to neutron computed tomography (NCT). New approaches using some advanced neutron converters, a high sensitive and resolution TV camera and a high performance image processing system are being undertaken for standard indicators, visualization on air-water two-phase flow, NCT and so on. (author).
1987-07-01
International Lens Design Conference, Monterey, CA, June 11-14, 1990, Proceedings
Energy Technology Data Exchange (ETDEWEB)
The present conference on lens design encompasses physical and geometrical optics, diffractive optics, the optimization of optical design, software packages, ray tracing, the use of artificial intelligence, the achromatization of materials, zoom optics, microoptics and GRIN lenses, and IR lens design. Specific issues addressed include diffraction-performance calculations in lens design, the optimization of the optical transfer function, a rank-down method for automatic lens design, applications of quadric surfaces, the correction of aberrations by using HOEs in UV and visible imaging systems, and an all-refractive telescope for intersatellite communications. Also addressed are automation techniques for optics manufacturing, all-reflective phased-array imaging telescopes, the thermal aberration analysis of a Nd:YAG laser, the analysis of illumination systems, athermalized FLIR optics, and the design of ...
1990-01-01
Technetium complexes as potential brain imaging agents
International Nuclear Information System (INIS)
Single photon tomography using lipophilic tracers provides tomographic representations of regional blood flow. To penetrate a healthy blood-brain barrier requires that radiotracers either are fat-soluble or have an affinity for one of the selective blood-brain barrier transport systems. In recent years there has been an increasing interest to explore the ideal physical characteristics of "9"9"mTc for diagnostic problems of brain diseases. The development of radiopharmaceuticals for brain imaging including the intensively studied "9"9"mTc-propyleneamineoxime derivatives is discussed. (author).
Energy Technology Data Exchange (ETDEWEB)
Electron energy loss (EEL) spectroscopy and high angle annular dark field (HAADF) imaging in aberration-corrected electron microscopes are powerful techniques to determine the chemical composition and structure of materials at atomic resolution. We have implemented Smart Acquisition, a flexible system of scanning transmission electron microsocpy (STEM) beam position control and EELS collection, on two aberration-corrected dedicated cold field emission gun (FEG) STEMs located at SuperSTEM, Daresbury Laboratory. This allows the collection of EEL spectra from spatially defined areas with a much lower electron dose possible than existing techniques such as spectrum imaging.
2010-07-01
Energy Technology Data Exchange (ETDEWEB)
The book is intended as a source of information for general practioners and for medical students doing their practical training. Efficient application of imaging methods is explained with great emphasis on practical aspects, concentrating on typical tasks to be solved for adult patients with internal disease or surgical problems. The material is arranged by various organic systems of the body. Graded diagnostics for a stepwise approach to the final diagnosis is the concept described, and is shown to be of advantage to the patient and in terms of cost and time.
1985-01-01
International Nuclear Information System (INIS)
Radiology departments often underestimate the importance of protecting medical data during transmission, including the precautions taken to ensure data protection. In teleradiology, transmitted as well as stored patient data have to be signed digitally according to the currently valid regulation (Roentgenverordnung, RoeV). The DICOM standard facilitates a digital signature. So far, medical image manufacturers only announced to support this security feature. We introduce a solution that extends the feature of digital signing to older modalities. (orig.)
2005-01-01
UK PubMed Central (United Kingdom)
Gadolinium (Gd) based contrast agents (GBCAs) in magnetic resonance imaging (MRI) are used in daily clinical practice and appear safe in most patients; however, nephrogenic systemic fibrosis...Full Text Available
2009-03-01
Measurements of nuclear emulsion tracks by means of a picture analysis system
Energy Technology Data Exchange (ETDEWEB)
A semiautomatic system for measurements of nuclear tracks in nuclear emulsion is described. The microscopic image of a particle track is picked up by a video camera. The video picture is digitized in real time. The picture analysis is done via software. The microscope is equipped with a stepping motor driven stage which is also computer-controlled.
1986-01-01
Energy Technology Data Exchange (ETDEWEB)
Intravenous digital subtraction angiography using Fuji computed radiography system (FCR-DSA) was used to evaluate 57 preoperative patients with clinical manifestations of peripheral vascular disease of lower extremity. With its high contrast resolution and good special resolution, image of FCR-DSA could offer optimal information of vascular abnormality in lower extremity distal to midfoot for the diagnosis and the choice of management.
1987-03-01
International Nuclear Information System (INIS)
Intravenous digital subtraction angiography using Fuji computed radiography system (FCR-DSA) was used to evaluate 57 preoperative patients with clinical manifestations of peripheral vascular disease of lower extremity. With its high contrast resolution and good special resolution, image of FCR-DSA could offer optimal information of vascular abnormality in lower extremity distal to midfoot for the diagnosis and the choice of management. (orig.).
1987-01-01
Real-time neutron radiography at Texas A and M University
Energy Technology Data Exchange (ETDEWEB)
A real-time neutron radiography imaging system has been installed at the Texas A and M University Nuclear Science Center. The system employs a scintillating screen viewed by a low-light TV camera with a front surface mirror placed at 45deg to the neutron beam. The key components of the system are the neutron camera and the image capture and processing unit. The neutron camera uses an NE 426 scintillating screen (ZnS), front surface mirror, remote focus and zoom lens, intensified relay optics (IRO) and monochrome CCD television camera. The image capture and processing unit consists of an IBM PC AT-compatible computer, arithmetic frame grabber, frame processor and high-resolution color monitor. The neutron camera is similar to others using a silicon intensified target (SIT) television camera to provide a TV image of the low-level light from a ...
1990-12-20
Real-time neutron radiography at Texas A and M University
International Nuclear Information System (INIS)
A real-time neutron radiography imaging system has been installed at the Texas A and M University Nuclear Science Center. The system employs a scintillating screen viewed by a low-light TV camera with a front surface mirror placed at 45deg to the neutron beam. The key components of the system are the neutron camera and the image capture and processing unit. The neutron camera uses an NE 426 scintillating screen (ZnS), front surface mirror, remote focus and zoom lens, intensified relay optics (IRO) and monochrome CCD television camera. The image capture and processing unit consists of an IBM PC AT-compatible computer, arithmetic frame grabber, frame processor and high-resolution color monitor. The neutron camera is similar to others using a silicon intensified target (SIT) television camera to provide a TV image of the low-level light from a ...
1990-12-01
Evaluation of FCR system by means of NEQ(u)
Energy Technology Data Exchange (ETDEWEB)
A number of noise equivalent quanta (NEQ(u)) has been used in the evaluation of imaging systems. In this paper, we have evaluated the image quality of Fuji computed radiography (FCR) using of NEQ (u) and considered with the effects of the aliasing error of the FCR. The noise samples of the FCR were made by three different exposure levels, and one of these has the same exposure level of the screen-film system. These samples were set with the same characteristic curve condition as that of the screen-film system. Results indicate that NEQ (u) of the FCR system at low frequencies varies depending on the exposure level. On the same exposure level, NEQ(u) of screen-film system has a higher value than that of FCR in the frequency region over 2.5 cycles/mm. Moreover, the aliasing error of FCR increases at the frequency region over 5 cycles/mm. We ...
1991-07-01
Evaluation of FCR system by means of NEQ(u)
International Nuclear Information System (INIS)
A number of noise equivalent quanta (NEQ(u)) has been used in the evaluation of imaging systems. In this paper, we have evaluated the image quality of Fuji computed radiography (FCR) using of NEQ (u) and considered with the effects of the aliasing error of the FCR. The noise samples of the FCR were made by three different exposure levels, and one of these has the same exposure level of the screen-film system. These samples were set with the same characteristic curve condition as that of the screen-film system. Results indicate that NEQ (u) of the FCR system at low frequencies varies depending on the exposure level. On the same exposure level, NEQ(u) of screen-film system has a higher value than that of FCR in the frequency region over 2.5 cycles/mm. Moreover, the aliasing error of FCR increases at the frequency region over 5 cycles/mm. We ...
1991-01-01
Energy Technology Data Exchange (ETDEWEB)
In the field of reactor and fuel cycle physics, particle transport plays and important role. Neutronic design, operation and evaluation calculations of nuclear system make use of large and powerful computer codes. However, current limitations in terms of computer resources make it necessary to introduce simplifications and approximations in order to keep calculation time and cost within reasonable limits. Two different types of methods are available in these codes. The first one is the deterministic method, which is applicable in most practical cases but requires approximations. The other method is the Monte Carlo method, which does not make these approximations but which generally requires exceedingly long running times. The main motivation of this work is to investigate the possibility of a combined use of the two methods in such a way as to retain their advantages while avoiding their drawbacks. Our work has mainly focused on the speed-up of ...
2000-05-19
Surface-loss power calculations for the LANSCE DTL
Energy Technology Data Exchange (ETDEWEB)
The surface losses in the drift-tube linac (DTL) tanks 3 and 4 of the LANSCE linear accelerator are calculated using 3-D electromagnetic modeling with the CST MicroWave Studio (MWS). The results are used to provide more realistic power estimates for the 201.25MHz RF upgrade design within the LANSCE-R project. We compared 3-D MWS results with those from traditional 2-D Superfish computations for DTL cells and their simplified models and found differences on the level of a few percent. The differences are traced to a 3-D effect consisting in a redistribution of the surface currents on the drift tubes (DT) produced by the DT stem. The dependence of MWS results on the mesh size used in computations is also discussed.
2008-01-01
First trimester measurements of nasal bone length using three-dimensional ultrasound
British Library Electronic Table of Contents (United Kingdom)
Objectives To investigate the feasibility and reproducibility of measurements of nasal bone length using a three-dimensional (3D) ultrasound in the first trimester. Methods In a prospective study, 118 consecutive pregnant women attending for Down syndrome screening at 11-13 + 6 weeks were recruited. They had successful fetal nasal bone measurement by two-dimensional (2D) ultrasound by four operators. Three-dimensional volumes were recorded in the mid-sagittal plane of fetal profile by the fifth operator and examined using multiplanar techniques. Another independent investigator randomly compared his measurements with one of the four operators. Results In the subsequent 3D examination, the nasal bone length could be examined in 94 cases (79.7%). The mean difference between the 2D and 3D mea...
2009-01-01
3D model for a secondary facultative pond
British Library Electronic Table of Contents (United Kingdom)
This paper describes a comprehensive model of wastewater treatment in secondary facultative ponds, which combines 3D hydrodynamics with a mechanistic water quality model. The hydrodynamics are based on the Navier-Stokes equation for incompressible fluids under shallow water and Boussinesq assumptions capturing the flow dynamics along length, breadth and depth of the pond. The water quality sub model is based on the Activated Sludge Model (ASM) concept, describing COD and nutrient removal as function of bacterial growth following Monod kinetics, except for Escherichia coli removal, which was modelled as first order decay. The model was implemented in the Delft3D software and was used to evaluate the effect of wind and the addition of baffles on the water flow pattern, temperature profiles i...
2011-01-01
Representation of uncertainty in computer vision using fuzzy sets
Energy Technology Data Exchange (ETDEWEB)
Uncertainty in computer vision can arise at various levels. It can occur in the low level in the raw sensor input, and extends all the way through intermediate and higher levels. Ideally, at any level where decisions are being made on the basis of previous processing steps, a computer vision system must have sufficient flexibility for representation of uncertainty in any of these levels. The input cue representation portion of a computer vision system should maintain the information content of the original input images, while at the same time allowing for uncertainty in the identification of attributes required by other parts of the system for decision making. Processes such as edge detection, segmentation, and shape matching yield results which could bias higher level decision making, unless some framework is defined for the representation of uncertainty in the context of fuzzy set theory where ...
1986-02-01
MR imaging of regional late brain development
International Nuclear Information System (INIS)
This paper reports, to complement current knowledge on brain development, late regional brain maturation assessed with quantitative MR imaging. Axial and coronal head spin-echo (SE) images were obtained in 60 healthy individuals aged 5--56 years, with a double-echo, flow compensated imaging sequence obtained with a 1.5-T Magnetom spectroscopy and imaging system. T2-weighted images were calculated from the intensity differences in SE images at echo times (TEs) of 15 and 90 msec (TR = 2.5 second). The mean T2 values were determined at 16 sites in each cerebral hemisphere. T2 values of the six frontal subcortical white matter (FSCWM) sites and of the internal capsule (IC) were evaluated. Mean T2 values in the IC decreased until age 10 years, whereas this decrease continued in the FSCWM past age 15 years before reaching a plateau. Differential ...
Implementation of Accelerated Beam-Specific Matched-Filter-Based Optical Alignment
Energy Technology Data Exchange (ETDEWEB)
Accurate automated alignment of laser beams in the National Ignition Facility (NIF) is essential for achieving extreme temperature and pressure required for inertial confinement fusion. The alignment achieved by the integrated control systems relies on algorithms processing video images to determine the position of the laser beam images in real-time. Alignment images that exhibit wide variations in beam quality require a matched-filter algorithm for position detection. One challenge in designing a matched-filter based algorithm is to construct a filter template that is resilient to variations in imaging conditions while guaranteeing accurate position determination. A second challenge is to process the image as fast as possible. This paper describes the development of a new analytical template that captures key recurring features present in the beam ...
2009-01-29
Energy Technology Data Exchange (ETDEWEB)
For heavy-ion beam driven inertial fusion ''liquid-protected'' reactor designs such as HYLIFE-II, a mixture of molten salts made of F{sup 10}, Li{sup -6}, Li{sup 7} and Be{sup 9} (called flibe) allows small chambers and final-focus magnets closer to the target with superconducting coils suffering higher radiation damage, though they can stand only a certain amount of energy deposited before quenching. This work has been primarily focusing on verifying that total energy deposited by fusion neutrons and induced gamma rays remain under such limit values and the final purpose is the optimization of the shielding of the magnetic lens system from the points of view of the geometrical configuration and of the physical nature of the materials adopted. The system is analyzed in terms of six geometrical models going from simplified up to much more realistic representations of a system of 192 beam ...
2002-07-01
Real-time neutron radiography system performance - Measurements and methods
Energy Technology Data Exchange (ETDEWEB)
The University of Virginia's real-time neutron radiography facility was characterized by measurement of the total neutron flux, gold/cadmium ratio, neutron/gamma ratio, and the effective collimar length-to-aperture diameter (L/D) ratio. The real-time neutron imaging system and collimator were further characterized by measuring the modulation transfer function (MTF) of the system. The collimator effectiveness was measured by using the MTF to determine the ''unparallelism'' of the neutron beam. The computer-based image processing system allowed rapid calculation of the MTF and the collimator effectiveness. The results of these measurements, using no collimator and a simple tube collimator, demonstrated the method's ability to determine the effective L/D ratio. The MTF measurement scheme provided a fast, reliable, and reproducible ...
1988-09-01
Real-time neutron radiography system performance - Measurements and methods
International Nuclear Information System (INIS)
The University of Virginia's real-time neutron radiography facility was characterized by measurement of the total neutron flux, gold/cadmium ratio, neutron/gamma ratio, and the effective collimar length-to-aperture diameter (L/D) ratio. The real-time neutron imaging system and collimator were further characterized by measuring the modulation transfer function (MTF) of the system. The collimator effectiveness was measured by using the MTF to determine the ''unparallelism'' of the neutron beam. The computer-based image processing system allowed rapid calculation of the MTF and the collimator effectiveness. The results of these measurements, using no collimator and a simple tube collimator, demonstrated the method's ability to determine the effective L/D ratio. The MTF measurement scheme provided a fast, reliable, and reproducible means of monitoring any changes in the real-time ...
1988-01-01
Development of lidar techniques for environmental studies
Energy Technology Data Exchange (ETDEWEB)
The lidar group in Lund has performed many DIAL measurements with a mobile lidar system that was first described in 1987. The lidar system is based on a Nd:YAG-pumped dye laser. During the last few years the lidar group has focused on fluorescence imaging and mercury measurements in the troposphere. In 1994 we performed two campaigns: one fluorescence imaging measurement campaign outside Avignon, France and one unique lidar campaign at a mercury mine in Almaden, Spain. Both campaigns are described in this thesis. This thesis also describes how the mobile lidar system was updated with the graphical programming language LabVIEW to obtain a user friendly lidar system. The software controls the lidar system and analyses measured data. The measurement results are shown as maps of species concentration. All electronics and the major parts of the ...
1996-09-01
Design of multifunction anti-terrorism robotic system based on police dog
Aimed at some typical constraints of police dogs and robots used in the areas of reconnaissance and counterterrorism currently, the multifunction anti-terrorism robotic system based on police dog has been introduced. The system is made up of two parts: portable commanding device and police dog robotic system. The portable commanding device consists of power supply module, microprocessor module, LCD display module, wireless data receiving and dispatching module and commanding module, which implements the remote control to the police dogs and takes real time monitor to the video and images. The police dog robotic system consists of microprocessor module, micro video module, wireless data transmission module, power supply module and offence weapon module, which real time collects and transmits video and image data of the counter-terrorism sites, and gives military ...
2007-11-01
A REAL-TIME COAL CONTENT/ORE GRADE (C2OC) SENSOR
Energy Technology Data Exchange (ETDEWEB)
This is the final report of a three year DOE funded project titled ''A real-time coal content/ore grade (C{sub 2}OG) sensor''. The sensor, which is based on hyperspectral imaging technology, was designed to give a machine vision assay of ore or coal. Sensors were designed and built at Resonon, Inc., and then deployed at the Stillwater Mining Company core room in southcentral Montana for analyzing platinum/palladium ore and at the Montana Tech Spectroscopy Lab for analyzing coal and other materials. The Stillwater sensor imaged 91' of core and analyzed this data for surface sulfides which are considered to be pathfinder minerals for platinum/palladium at this mine. Our results indicate that the sensor could deliver a relative ore grade provided tool markings and iron oxidation were kept to a minimum. Coal, talc, and titanium sponge samples were also imaged and analyzed for content ...
2005-04-01
Optical Images Due to Lenses and Mirrors
... Title : Optical Images Due to Lenses and Mirrors. ... Abstract : The properties of real and virtual images formed by lenses and mirrors are reviewed. ...
Fast Implementation of Matched Filter Based Automatic Alignment Image Processing
Energy Technology Data Exchange (ETDEWEB)
Video images of laser beams imprinted with distinguishable features are used for alignment of 192 laser beams at the National Ignition Facility (NIF). Algorithms designed to determine the position of these beams enable the control system to perform the task of alignment. Centroiding is a common approach used for determining the position of beams. However, real world beam images suffer from intensity fluctuation or other distortions which make such an approach susceptible to higher position measurement variability. Matched filtering used for identifying the beam position results in greater stability of position measurement compared to that obtained using the centroiding technique. However, this gain is achieved at the expense of extra processing time required for each beam image. In this work we explore the possibility of using a field programmable logic array (FPGA) to speed up these computations. The ...
2008-04-02
This paper proposes a new pattern recognition system employing optical joint transform correlation (JTC) technique which offers a great number of advantages over similar digital techniques, including very fast operation, simple architecture and capability of updating the reference image in real time. The proposed JTC technique incorporates a synthetic discriminant function (SDF) of the target image estimated from different training images to make the pattern recognition performance invariant to noise and distortion. It then involves four different phase-shifted versions of the same target SDF reference image, which are individually joint transform correlated with the given input scene. When the correlation signals are combined, it produces a single cross-correlation peak corresponding to each potential target present in the given input scene. The proposed technique also includes a ...
2011-04-01
Determination of Inter-Phase Line Tension in Langmuir Films
A Langmuir film is a molecularly thin film on the surface of a fluid; we study the evolution of a Langmuir film with two co-existing fluid phases driven by an inter-phase line tension and damped by the viscous drag of the underlying subfluid. Experimentally, we study an 8CB Langmuir film via digitally-imaged Brewster Angle Microscopy (BAM) in a four-roll mill setup which applies a transient strain and images the response. When a compact domain is stretched by the imposed strain, it first assumes a bola shape with two tear-drop shaped reservoirs connected by a thin tether which then slowly relaxes to a circular domain which minimizes the interfacial energy of the system. We process the digital images of the experiment to extract the domain shapes. We then use one of these shapes as an initial condition for the numerical solution of a boundary-integral model of the underlying hydrodynamics and compare the ...
2007-01-01
Development of a computerized portal verification scheme for pelvic treatment fields
International Nuclear Information System (INIS)
Purpose/Objective: At present, treatment verification between portal and reference images is performed based on manually-identified features by radiation oncologist, which is both time-consuming and potentially error-prone. There is a demand for the computerized verification procedure in clinical application. The purpose of this study is to develop a computerized portal verification scheme for pelvic treatment fields. Materials/Methods: The automated verification system involves image acquisition, image feature extraction, feature matching between reference and portal images and quantitative evaluation of patient setup. Electronic portal images with a matrix size of 256 x 256 and 12 bit gray levels were acquired using a liquid matrix electronic portal imaging device. Simulation images were acquired by digitizing ...
1996-09-01
Energy Technology Data Exchange (ETDEWEB)
This short article discusses the results of a market survey on ventilation systems for residential buildings and the role played by ventilation systems in our daily lives. Problems incurred as a result of insufficient ventilation conditions such as the formation of mould in dwellings whose windows have been replaced with better seals are discussed, for example. The negative image of air-conditioning and its causes are examined. The need for action in this area is stressed. Further findings of the study are presented, including a detailed review of current equipment and scenarios on how these systems can develop in the future. The extension of the study to cover the situation in further European countries is mentioned.
2003-07-01
Endomicroscopy imaging of epithelial structures using tissue autofluorescence
We explore autofluorescence endomicroscopy as a potential tool for real-time visualization of epithelial tissue microstructure and organization in a clinical setting. The design parameters are explored using two experimental systems--an Olympus Medical Systems Corp. stand-alone clinical prototype probe, and a custom built bench-top rigid fiber conduit prototype. Both systems entail ultraviolet excitation at 266 nm and/or 325 nm using compact laser sources. Preliminary results using ex vivo animal and human tissue specimens suggest that this technology can be translated toward in vivo application to address the need for real-time histology.
2011-04-01
Commercialization of uncooled infrared technology
BAE Systems is the leading producer of uncooled microbolometer based thermal imaging engines in the world. Initial investments to develop and produce uncooled infrared (IR) technology were primarily driven by military applications, but it was the commercial market with the potential for large product volumes which provided BAE Systems with the business model required for investment in uncooled IR technology. This paper reviews the heritage of BAE Systems technology and current products and is an example of the success of a Dual-Use technology area which DARPA invested in during the 1990s.
2004-10-01
Two-photon calcium imaging from head-fixed Drosophila during optomotor walking behavior
British Library Electronic Table of Contents (United Kingdom)
Drosophila melanogaster is a model organism rich in genetic tools to manipulate and identify neural circuits involved in specific behaviors. Here we present a technique for two-photon calcium imaging in the central brain of head-fixed Drosophila walking on an air-supported ball. The ball's motion is tracked at high resolution and can be treated as a proxy for the fly's own movements. We used the genetically encoded calcium sensor, GCaMP3.0, to record from important elements of the motion-processing pathway, the horizontal-system lobula plate tangential cells (LPTCs) in the fly optic lobe. We presented motion stimuli to the tethered fly and found that calcium transients in horizontal-system neurons correlated with robust optomotor behavior during walking. Our technique allows both behavior ...
2010-01-01
Quantitation of Cellular Dynamics in Growing Arabidopsis Roots with Light Sheet Microscopy
To understand dynamic developmental processes, living tissues must be imaged frequently and for extended periods of time. Root development is extensively studied at cellular resolution to understand basic mechanisms underlying pattern formation and maintenance in plants. Unfortunately, ensuring continuous specimen access, while preserving physiological conditions and preventing photo-damage, poses major barriers to measurements of cellular dynamics in indeterminately growing organs such as plant roots. We present a system that integrates optical sectioning through light sheet fluorescence microscopy with hydroponic culture that enables us to image at cellular resolution a vertically growing Arabidopsis root every few minutes and for several consecutive days. We describe novel automated routines to track the root tip as it grows, track cellular nuclei and identify cell divisions. We demonstrate the ...
2011-01-01
A position-sensitive event-counting electronic readout system for microchannel plates (MCPs) is described that offers the advantages of high spatial resolution and fast time resolution. The technique relies upon a four-quadrant electron-collecting anode located behind the output face of the microchannel plate, so that the electron cloud from each detected event is partly intercepted by each of the four quadrants. The relative amounts of charge collected by each quadrant depend on event position, permitting each event to be localized with two ratio circuits. A prototype quadrant anode system for ion, electron, and extreme ultraviolet imaging is described. The spatial resolution achieved, approx. =10 ..mu.., allows individual MCP channels to be distinguished. (AIP)
1976-11-01
International Nuclear Information System (INIS)
A position-sensitive event-counting electronic readout system for microchannel plates (MCPs) is described that offers the advantages of high spatial resolution and fast time resolution. The technique relies upon a four-quadrant electron-collecting anode located behind the output face of the microchannel plate, so that the electron cloud from each detected event is partly intercepted by each of the four quadrants. The relative amounts of charge collected by each quadrant depend on event position, permitting each event to be localized with two ratio circuits. A prototype quadrant anode system for ion, electron, and extreme ultraviolet imaging is described. The spatial resolution achieved, approx. =10 #mu#, allows individual MCP channels to be distinguished.
9472-01-01
Normalized noise power spectrum of full field digital mammography detector system
International Nuclear Information System (INIS)
Full text: A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through de trending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality. (author)
Normalized Noise Power Spectrum of Full Field Digital Mammography System
International Nuclear Information System (INIS)
A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through detrending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality.
2010-01-05
Jun 10, 2011 ... Subsonic flow past a semi-infinite flat plate is modeled at Reynolds number 6 ..... data is taken from Cook, McDonald, and Firmin, AGARD-AR-138, 1979, p. ...... too large a time-averaged separation bubble behind the hump. ...
Statistical properties of nucleotide clusters in DNA sequences*
UK PubMed Central (United Kingdom)
Using the complete genome of Plasmodium falciparum 3D7 which has 14 chromosomes as an example, we have examined the distribution functions for the amount of C or G and A or T consecutively...Full Text Available
2005-05-01
Robust principal axes determination for point-based shapes using least median of squares
UK PubMed Central (United Kingdom)
A robust technique for determining the principal axes of a 3D shape represented by a point set, possibly with noise, is presented. We use techniques from robust statistics to guide the classical...Full Text Available
2009-04-01
Phase separation, pore structure, and properties of nanofibrous gelatin scaffolds
UK PubMed Central (United Kingdom)
The development of three-dimensional (3D) biomimetic scaffolds which provide an optimal environment for cells adhesion, proliferation and differentiation, and guide new tissue formation has...Full Text Available
2009-09-01
PRISM 3D: Global Warming Analysis
Estimates of global warming during the mid-Piacenzian Age of the Pliocene Epoch suggest temperatures were 2 degrees C greater than today. ... million years approaches this level of warming. PRISM/Global Warmin...
Modelling the masticatory biomechanics of a pig
UK PubMed Central (United Kingdom)
The relationships between muscle tensions, jaw motions, bite and joint forces, and craniofacial morphology are not fully understood. Three-dimensional (3-D) computer models are able to combine anatomical...Full Text Available
2002-11-01
Energy Technology Data Exchange (ETDEWEB)
Metacad is a collection of routines which creates a randomly accessible data structure from Applicon's APPLE-3D data format and supplies a logical method for manipulation of the data structure by a CAD application program.
1983-05-01
Approximately 62,000 lbs Fuel Load: 58,000 lbs. Type Fuel: JP4, JP5, JP8, JET A, JET A-1, JET B Standard Fuel Burn: 4500 - 6000 lbs/hr depending on altitude and airspeed Maximum...
2011-08-17
Heat transfer augmentation in 3D internally finned and microfinned helical tube
Energy Technology Data Exchange (ETDEWEB)
Experiments are performed to investigate the single-phase flow and flow-boiling heat transfer augmentation in 3D internally finned and micro-finned helical tubes. The tests for single-phase flow heat transfer augmentation are carried out in helical tubes with a curvature of 0.0663 and a length of 1.15 m, and the examined range of the Reynolds number varies from 1000 to 8500. Within the applied range of Reynolds number, compared with the smooth helical tube, the average heat transfer augmentation ratio for the two finned tubes is 71% and 103%, but associated with a flow resistance increase of 90% and 140%, respectively. A higher fin height gives a higher heat transfer rate and a larger friction flow resistance. The tests for flow-boiling heat transfer are carried out in 3D internally micro-finned helical tube with a curvature of 0.0605 and a length of 0.668 m. Compared with that in the smooth helical ...
2005-05-01
Electrospun nanofibers composed of biodegradable polymers are attractive candidates for cell culture scaffolds in tissue engineering. Their fine-meshed structures, resembling natural extracellular matrices, effectively interact with cell surfaces and promote cell proliferation. The application of electrospinning, however, is limited to two-dimensional (2D) or single tube-like scaffolds, and the fabrication of arbitrary three-dimensional (3D) scaffolds from electrospun nanofibers is still very difficult due to the fibers' continuous and entangled form. To address this issue, in this paper, we describe the use of phase-separation-assisted electrospray and electrostatic focusing to perform continuous direct 3D patterning of nanofibrous microcapsules of biodegradable polylactic acid (PLA). These microcapsules exhibit fiber-particle duality because they are composed of nanofibers suitable for cell attachment ...
2011-09-01
Computational study of jet interaction flow field with and without incidence
International Nuclear Information System (INIS)
The objective was to study the interaction of a side jet with the incoming supersonic flow and hypersonic flow. Qualitatively same Cp trends have been obtained as found experimentally. Also in aerodynamic coefficients side jet interaction results in additional pitching moment which is because of the high pressure region in upstream of the jet and a low pressure region in the downstream of the jet. Also jet interaction results in the rise in the lift coefficient. Whereas in the incidence case, simulation has been performed for the hypersonic flows over a biconic body with supersonic lateral jet at Mach 9.7 and incidence of 0"o to incidence of -12"o and 12"o. The results obtained were compared with the experimental and CFD code CFL3D results. PAK-3D over predicts the surface pressure as compared to the CFL3D and experimental results, whereas the qualitative trends ...
2004-05-09
Characterization of 3D thermal neutron semiconductor detectors
International Nuclear Information System (INIS)
Neutron semiconductor detectors for neutron counting and neutron radiography have an increasing importance. Simple silicon neutron detectors are combination of a planar diode with a layer of an appropriate neutron converter such as 6LiF. These devices have limited detection efficiency of not more than 5%. The detection efficiency can be increased by creating a 3D microstructure of dips, trenches or pores in the detector and filling it with a neutron converter. The first results related to the development of such devices are presented. Silicon detectors were fabricated with pyramidal dips on the surface covered with 6LiF and then irradiated by thermal neutrons. Pulse height spectra of the energy deposited in the sensitive volume were compared with simulations. The detection efficiency of these devices was about 6.3%. Samples with different column sizes were fabricated to study the electrical properties of ...
2007-06-11
A self-oscillating biophysical computer model of the elongated vocal fold
UK PubMed Central (United Kingdom)
A new 3D model is developed to simulate the self-oscillation of the elongated vocal folds. This model allows for large deformation and longitudinal displacement. The displacement boundary condition...Full Text Available
2008-01-01
International Nuclear Information System (INIS)
This paper presents a new methodology to create realistic 3D microstructures of polycrystals. The virtual microstructures are based on statistical data describing the morphological and crystallographic textures of a sample, obtained from an EBSD analysis. In addition, the methodology can reproduce the observed surface on top of the simulated microstructure. This feature allows finite element calculations on these virtual aggregates to be compared to experimental results of mechanical tests. Such a comparison leads to the identification of the mechanical parameters of constitutive laws, such as critical resolved shear stress and strain hardening, using an optimization algorithm. Two materials were simulated in this study: TiAl and grade 702 zirconium. The first one presents twins inside the microstructure and the second one has an anisotropic texture. Based on 2D simulations, the important parameters necessary to describe a microstructure were ...
UK PubMed Central (United Kingdom)
Developing in vitro engineered hepatic tissues that exhibit stable phenotype is a major challenge in the field of hepatic tissue engineering. However, the rapid dedifferentiation of...Full Text Available
In our previous paper (Lanzafame et al. 2000, PASJ 52, 515) we showed, through 2D SPH simulations, that the stellar mass ratio, M 2 / M 1, of a close binary system (that determines the position and then the initial specific angular momentum at L 1) plays a fundamental role in the formation and development of spiral structures and shock fronts in the radial flow of accretion discs. In that work only a quasi-sonic value of the injection velocity at L 1 was considered. In the present work we also carried out 2D SPH simulations with the aim to investigate the development of such structures, while keeping constant the mass of the compact primary (M 1 = 1 M odot) and the separation between the two components, and assuming as an initial condition of two different supersonic injection velocities at L 1, characterizing two sets of simulations. For each set we considered four values of the secondary to primary mass ratio, M 2 / M 1. We worked out 2D models because the ...
2001-02-01
Energy Technology Data Exchange (ETDEWEB)
A feasibility study test and 3 field trials were performed at Darlington NGS in 1996, 1999 and 2000 on ABB LP turbines. The scope of these trials was to commission in-situ automatic phased array systems capable to inspect blade roots and rotor steeples of L-0 and L-1 rows. GE disk-blade rim attachments were inspected at Bruce B nuclear station, in fall of 1999. The automated ultrasonic phased array technology is capable of high-speed rate and reliable detection and sizing. The capability demonstration was performed on mock-ups and reference blocks, using EDM notches. A custom built UT simulation software: Imagine 3D interfaces with SimScan to generates the spreadsheets/charts with target and probe coordinates and ultrasonic path and angles (refracted and skew) to hit the reference target. Examination of L-0 blade and rotor steeple grooves was performed with 2 phased array systems under networking. Data ...
2000-07-01
First-break refraction event picking and seismic data trace editing using neural networks
Energy Technology Data Exchange (ETDEWEB)
Interactive seismic processing systems for editing noisy seismic traces and picking the first-break refraction events have been developed using a neural network learning algorithm. The authors employ a back propagation neural network (BNN) paradigm modified to improve the convergence rate of the BNN. The BNN is interactively trained'' to edit seismic data or pick first breaks by a human processor who judiciously selects and presents to the network examples of trace edits or refraction picks. The network then iteratively adjusts a set of internal weights until it can accurately duplicate the examples provided by the user. After the training session is completed, the BNN system an then process new data sets in a manner that mimics the human processor. Synthetic modeling studies indicated that the BNN uses many of the same subjective criteria that humans employ in editing and picking seismic data sets. Automated trace editing and ...
1993-01-01
Accident analysis in research reactors
International Nuclear Information System (INIS)
Full text: Full text: The incomplete understanding of the complex mechanisms connected with the interaction between thermal-hydraulic and neutron kinetics still challenges the design and the operation of nuclear reactors and imposes the adoption of conservatism in the evaluation of safety limits. The recent availability of powerful computer and computational techniques together with the continuing increase in operational experience suggests the revisiting of those areas and the identification of design/operation requirements that can be relaxed. So far, almost all of the safety analyses of research reactors have been performed using conservative computational tools such as channel codes but, nowadays, the application of Best-Estimate (BE) methods constitutes a real necessity. The global aim of the current work is an attempt to apply the best-estimate system thermal-hydraulic code Relap5. For this purpose, the generic IAEA research reactor Benchmark problem is ...
2006-10-15
A CANDU-6 versus ACR-1000 SDS1 performance comparison during some LOCA scenarios
International Nuclear Information System (INIS)
According to the Romanian Nuclear Strategy, the third and fourth units of the Cernavoda NPP will be commissioned by 2015. Improvements in operation and safety are expected to be applied for these CANDU-6 based units. On the other side, the need for innovation determined AECL to promote the ACR -1000 - an evolutionary Generation III+ power reactor design and a necessary step towards Generation IV inherently safe nuclear energy systems. CANDU-6 is recognized for having two independent fully capable shutdown systems. ACR-1000 also benefits for this strong safety feature. Two major achievements i.e. using of light water as coolant and using Low Enriched Uranium (LEU) as fuel in a compact heavy water moderated lattice allowed the obtaining of a slightly negative Coolant Void Reactivity (CVR) for the first time in a CANDU-type reactor. The main goal of the paper is to compare the response of SDS1 action during some LOCAs supposed to take place both ...
2009-10-12
Measuring q sub 0 using supernovae at z approx 0. 3
Energy Technology Data Exchange (ETDEWEB)
The measurement of q{sub o} is extremely important for understanding the quantity of matter in our universe. The measurement of q{sub o} using supernovae of type Ia as standard candles is appealing because it requires less modeling than other methods using galaxies. The challenge with using supernovae to measure q{sub o} is in finding enough of them. In order to find supernovas, we have constructed a very popular f/1 camera for the 3.9m Anglo-Australian Telescope. The camera uses reducing optics that put a 17 in. {times} 17 in. field on a 1024 {times} 1024 pixel Thomson CCD. Using this system, we image to 23rd magnitude in five minutes. We have developed a software package that uses image subtraction to find supernovae that are approximately magnitude 22.4 or brighter in these images. One field can be processed every 6.6 minutes on a relatively unloaded VAX 6000-6510. We estimate that this ...
1992-07-01
We will present the first astronomical images taken with MIRSI (Mid-InfraRed Spectrometer and Imager). First light for MIRSI is scheduled for December 2001. MIRSI is a mid-infrared camera system recently completed at Boston University that has both spectroscopic and imaging capabilities. The camera utilizes a new 320x240 Si:As IBC array developed for ground-based astronomy by Raytheon/SBRC. MIRSI offers a large field of view (1.6 arcmin x 1.2 arcmin at the IRTF with a pixel scale of 0.3 arcsec), diffraction-limited spatial resolution, complete spectral coverage over the 8-14 micron and 17-26 micron atmospheric windows for both imaging (discrete filters and CVF) and spectroscopy (10 and 20 micron grisms), and high sensitivity (expected 1-sigma point source sensitivities of 5 and 20 mJy at 10 and 20 microns, respectively, for on-source integration time of 30 seconds). This ...
2001-12-01
International Nuclear Information System (INIS)
The measurement of K(alpha)/K(beta) X-ray intensity ratio indicates the excitation process and the chemical state of the atom examined. Theoretical considerations on the origin of this property are presented. The difference of these ratios following photoionization and electron capture are calculated by a computer code generating transition matrix elements. The theoretical assumptions involved in the codes are tested by comparing the experimental and calculated data concerning 3d transition element atoms. (D.Gy.).
1981-03-19
Energy Technology Data Exchange (ETDEWEB)
Twenty-seven patients with symptoms or clinical findings suggesting joint or bone disorders of the anterior chest wall (ACW) were evaluated by spiral CT with 3-dimensional (3-D) and multiplanar reconstructions. Preceding conventional ACW tomography was performed in 10 patients. ACW joint and bone changes were visualized more adequately by coronal 2-D reconstructions based on spiral CT than by conventional tomography. In addition, nonossified costal cartilages and soft tissue lesions were demonstrated. 3-D reconstructions sometimes added information, especially in patients with fracture and dislocation. (orig.).
1994-09-01
PARALLEL 3-D SPACE CHARGE CALCULATIONS IN THE UNIFIED ACCELERATOR LIBRARY.
Energy Technology Data Exchange (ETDEWEB)
The paper presents the integration of the SIMBAD space charge module in the UAL framework. SIMBAD is a Particle-in-Cell (PIC) code. Its 3-D Parallel approach features an optimized load balancing scheme based on a genetic algorithm. The UAL framework enhances the SIMBAD standalone version with the interactive ROOT-based analysis environment and an open catalog of accelerator algorithms. The composite package addresses complex high intensity beam dynamics and has been developed as part of the FAIR SIS 100 project.
2006-06-26
Energy Technology Data Exchange (ETDEWEB)
The electronic structure of octahedral metal atom clusters Me/sub 6/ of 3d, 4d, and 5d transition metal atoms (V, Cr; Nb, Mo; Ta, W) has been calculated applying two different quantum-chemical approximation methods (Extended Hueckel (EH) method; SW-Xsub(alpha) method). Equilibrium structures, energy level schemes, Fermi energies and band widths as well as densities of states of clusters are discussed in detail.
1981-01-01
Anticonvulsant properties of selected pyrrolo[2,3-d]pyrimidine-2,4-diones and intermediates.
A series of pyrrolo[2,3-d]pyrimidine-2,4-diones and intermediates was tested for anticonvulsant activity in mice. Eleven of the 15 compounds possessed anticonvulsant activity against pentylenetetrazol-induced convulsions. One compound afforded more anticonvulsant protection against pentylenetetrazol than did trimethadione (67 and 50%, respectively). A suspension of this compound was found to be as effective as a solution in producing anticonvulsant activity. The results suggest that the nitrile analogs were more potent compared to the carbamyl analog due to higher lipid solubility. PMID:7373552
1980-04-01
Energy Technology Data Exchange (ETDEWEB)
We performed a comparative study of digitally and conventionally acquired images in gastrointestinal examinations. Radiation dose and spatial resolution were determined in a water phantom. In 676 examinations with either conventional or digital imaging (system: Diagnost 76, DSI) the number of images and the duration of the fluoroscopy time were compared. 101 examinations with digital as well as conventional documentation were evaluated by using 5 criteria describing the diagnostic performance. The entrance dose of the DSI is 12% to 36% of the film/screen system and the spatial resolution of the DSI may be better than that of a film/screen system with a speed of 200. The fluoroscopy time shows no significant difference between DSI and the film/screen technique. In 2 of 4 examination modes significantly more images were produced by the DSI. ...
1995-10-01
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.
