WorldWideScience
1

Ewald sphere correction for single-particle electron microscopy  

Energy Technology Data Exchange (ETDEWEB)

Most algorithms for three-dimensional (3D) reconstruction from electron micrographs assume that images correspond to projections of the 3D structure. This approximation limits the attainable resolution of the reconstruction when the dimensions of the structure exceed the depth of field of the microscope. We have developed two methods to calculate a reconstruction that corrects for the depth of field. Either method applied to synthetic data representing a large virus yields a higher resolution reconstruction than a method lacking this correction.

2006-03-15

2

Three-dimensional cranio-facial computed tomography  

International Nuclear Information System (INIS)

Computed tomography allows today to reconstruct three-dimensional (eD) images fram axial scans. The authors report their experience in cranio-facial pathology achived in two Departments of Radiology (University of Trieste, Italy and University of Standford, California). 3D images have been realized using two different softwares, one of which allows to reconstruct both soft tissue and bone structures. The application in maxillo-facial traumas, cranio-facial malformations and head tumours are disscussed. 3D images turned out to be very useful for the optimal visualization and for the spatial demostration of the lesion and have potential applications in cranio-facial surgery and radiotherapy.

1986-01-01

3

The role of 3D Helical CT in the reconstructive treatment of maxillofacial cancers  

International Nuclear Information System (INIS)

Purpose of this work is to investigate the role of Helical CT and the usefulness of three-dimensional (3D) imaging for pre-operative planning and follow-up of reconstructive maxillofacial surgery with alloplastic material in neoplastic disease involving this region. From 1996 to 1999 eleven patients were examined with Helical CT and 3D images for planning of maxillofacial plastic and reconstructive surgery for advanced cancer of this anatomically complex region. A 3D-modulated titanium mesh (100%) or micro nets was used to rebuild the anterior surface of maxillary bone and the orbital floor. The mesh was cut to the appropriate size and shape and curved where necessary. Within the residual sinusal cavity a siliconed filling was used surmounting an acrylic prosthesis with dental ...

2000-12-01

4

3-D brain CT image display for planning of craniofacial operation  

International Nuclear Information System (INIS)

The authors have been developing a 3D brain CT image display system for planning of craniofacial operations. This system helps doctors plan craniofacial operations on a graphic display (GD) terminal by rendering 3D images reconstructed from a set of slices. The authors reveal how the system generates 3D shapes of organs from given CT images and how it modifies or transforms the obtained shapes according to the user's request. The system functions now available are extraction and display of the skull and the skin, measurement of the distance between two points on the skull given through the GD terminal, and generating and eliminating a polygonal region arbitrarily given on the skull as an operative region. (Auth.).

5

Applicator reconstruction and applicator shifts in 3D MR-based PDR brachytherapy of cervical cancer  

British Library Electronic Table of Contents (United Kingdom)

Purpose To evaluate the methods of applicator reconstruction in 3D MR-based planning for brachytherapy of cervical cancer, and to investigate applicator shifts and changes in DVH parameters during PDR treatment. Methods For each application MR scans with applicator in situ were made: three T2-weighted (4.5mm slices) Turbo Spin Echo (TSE) scans and a balanced Steady State Free Precession scan (1.5mm). Three observers tested two applicator reconstruction methods: (A) directly on the bSSFP scan and (B) on a resampled combination of the three T2-weighted scans. For 10 patients MR imaging was repeated on the second day of each PDR fraction to determine applicator shifts and changes in DVH parameters. Results For both applicator reconstruction methods the interobserver variation for the DVH para...

2009-01-01

6

A novel method to characterize the MTF in 3D for computed mammotomography  

Science.gov (United States)

A novel phantom has been developed to measure the modulation transfer function (MTF) in 3D for x-ray computed tomography. The phantom consists of three tungsten wires, positioned nearly orthogonal to each other. Simultaneous measurements of the MTF are taken at various locations along the three orthogonal reconstructed planes. Our computed mammotomography (CmT) system uses a Varian Paxscan 2520 digital x-ray detector which can be positioned anywhere in ~2pi steradian band and can have arbitrary trajectories. With a half-cone beam geometry and with the phantom positioned near the center of rotation, projection images are acquired over 360 degrees. Various 3D orbits are evaluated including vertical axis of rotation and saddle. Reconstructions were performed using an iterative ordered-subsets transmission algorithm on rebinned projection ...

2006-03-01

8

A computer-assisted method for 3D subtraction angiography based on spiral CT  

International Nuclear Information System (INIS)

The objective of this study was to develop a method for 3D subtraction CT angiography and to optimize the visualization after semiautomatic segmentation. Ten patients with aneurysms of the abdominal aorta were examined using spiral CT. To reconstruct the vessels, as well as adjacent organs such as the liver and kidneys, one image data volume was acquired before and after injection of the contrast agent. The CT scans were obtained with a Siemens Somatom Plus 4. To improve the results of automatic segmentation, as well as visualization by maximum intensity projection (i.e. removal of bony structures), subtraction of both image volumes is necessary. However, small translation shifts disturb the subtraction process and produce artificial contours. To calculate the disparities along the three coordinate axes of two corresponding image volumes, a cepstrum filter is ...

9

Focused ion beam assisted three-dimensional rock imaging at submicron scale  

Energy Technology Data Exchange (ETDEWEB)

Computation of effective flow properties of fluids in porous media based on three dimensional (3D) pore structure information has become more successful in the last few years, due to both improvements in the input data and the network models. Computed X-ray microtomography has been successful in 3D pore imaging at micron scale, which is adequate for many sandstones. For other rocks of economic interest, such as chalk and diatomite, submicron resolution is needed in order to resolve the 3D-pore structure. To achieve submicron resolution, a new method of sample serial sectioning and imaging using Focused Ion Beam (FIB) technology has been developed and 3D pore images of the pore system for diatomite and chalk have been obtained. FIB was used in the milling of ...

2003-05-09

10

Automated three-dimensional X-ray analysis using a dual-beam FIB  

International Nuclear Information System (INIS)

We present a fully automated method for three-dimensional (3D) elemental analysis demonstrated using a ceramic sample of chemistry (Ca)MgTiO_x. The specimen is serially sectioned by a focused ion beam (FIB) microscope, and energy-dispersive X-ray spectrometry (EDXS) is used for elemental analysis of each cross-section created. A 3D elemental model is reconstructed from the stack of two-dimensional (2D) data. This work concentrates on issues arising from process automation, the large sample volume of approximately 17x17x10 #mu#m"3, and the insulating nature of the specimen. A new routine for post-acquisition data correction of different drift effects is demonstrated. Furthermore, it is shown that EDXS data may be erroneous for specimens containing voids, and that back-scattered electron images have to be used to correct for these errors.

2007-08-01

11

Multislice helical CT in the diagnosis of hilar cholangiocarcinoma  

International Nuclear Information System (INIS)

Objective: To investigate the value ofMSCT in observing the direct findings of hilar cholangiocarcinoma1Methods Multislice helical CT studies were performed on the upper abdomen in 19 consecutive patientswith painless jaundice1 Precontrast and dynamic contrast enhanced (25 s phase and 60 s phase) scanswere conducted, and 3D imageswere reconstructed using enhanced raw data in 15 cases1 The direct CT findings of hilar cholangiocarcinoma were studied by three radiologists respectively in a 32scale strategy1 The morphological features and extension of bile duct involvement by hilar cholangiocarcinoma were analyzed1 All the 19 caseswere pathologically p roved as hilar cholangiocarcinoma by surgery (15 cases) and ERCP ( 4 cases) 1 Results The direct findings and extension of hilar cholangiocarcinoma could be demonstrated in 14 out of 15 3D reconstruction ...

2005-11-01

12

Uranium Mass and Isotopic Analysis. A new drum tomographic gamma scanning system  

Energy Technology Data Exchange (ETDEWEB)

The NIS-6 group at Los Alamos National Laboratory pioneered the development of Tomographic Gamma Scanning and continue to improve its utility in real measurement situations. Building on this experience we report the development of a state of the art TGS system suitable for industrial applications. The image reconstruction and visualization software has been integrated into the familiar Canberra NDA2000 software suite which also handles all other aspects of the data acquisition and management. In this paper we describe the salient design and performance parameters of the system. The application of gamma-ray tomography to safeguards for improved assay accuracy and knowledge confirmation is discussed. In particular we compare and contrast the relative merits of this TGS and a traditional Segmented Gamma Scanner and illustrate how the 3-D visualization of the TGS image can provide ...

2003-05-01

13

Spiral CT with three-dimensional and multiplanar reconstruction in the diagnosis of anterior chest wall joint and bone disorders  

Energy Technology Data Exchange (ETDEWEB)

Twenty-seven patients with symptoms or clinical findings suggesting joint or bone disorders of the anterior chest wall (ACW) were evaluated by spiral CT with 3-dimensional (3-D) and multiplanar reconstructions. Preceding conventional ACW tomography was performed in 10 patients. ACW joint and bone changes were visualized more adequately by coronal 2-D reconstructions based on spiral CT than by conventional tomography. In addition, nonossified costal cartilages and soft tissue lesions were demonstrated. 3-D reconstructions sometimes added information, especially in patients with fracture and dislocation. (orig.).

1994-09-01

14

Repair of a Complex Congenital Cardiac Defect  

Medline Plus

... stenosis. It looks from the transesophageal and the 3-D echo that most of the problem is really ... posterior leaflet, which you can see on the 3-D echo image is a major source. The anterior ...

16

Usefulness of Computed Tomography in pre-surgical evaluation of maxillo-facial pathology with rapid prototyping and surgical pre-planning by virtual reality  

International Nuclear Information System (INIS)

Purpose. To validate a protocol for creating virtual models to be used in the construction of solid prototypes useful for the planning-simulation of maxillo-facial surgery, in particular for very complex anatomical and pathologic problems. To optimize communications between the radiology, engineering and surgical laboratories. Methods and materials. We studied 16 patients with different clinical problems of the maxillo-facial district. Exams were performed with multidetector computed tomography (MDCT) and single slice computed tomography (SDCT) with axial scans and collimation of 0.5-2 mm, and reconstruction interval of 1 mm. Subsequently we performed 2D multiplanar reconstructions and 3D volume-rendering reconstructions. We exported the DICOM images to the engineering laboratory, to recognize and isolate the bony structures by software. With these data the ...

2005-11-01

17

Three-dimensional, three-component wall-PIV  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a new time-resolved three-dimensional, three-component (3D-3C) measurement technique called wall-PIV. It was developed to assess near wall flow fields and shear rates near non-planar surfaces. The method is based on light absorption according to Beer-Lambert's law. The fluid containing a molecular dye and seeded with buoyant particles is illuminated by a monochromatic, diffuse light. Due to the dye, the depth of view is limited to the near wall layer. The three-dimensional particle positions can be reconstructed by the intensities of the particle's projection on an image sensor. The flow estimation is performed by a new algorithm, based on learned particle trajectories. Possible sources of measurement errors related to the wall-PIV technique are analyzed. The accuracy analysis was based on single particle experiments and a three-dimensional artificial data set ...

2010-06-15

18

3D MRI of the colon: methods and first results of 5 patients; 3D-MRT des Kolons: Methodik und erste Ergebnisse  

Energy Technology Data Exchange (ETDEWEB)

Purpose: `Exoscopic` and endoscopic identification of colorectal pathologies via MRI. Methods: 5 patients (36-88 years), two normal and three with different colorectal pathologies (diverticular disease, polyps and carcinoma of the colon), were examined by MRI after colonoscopy. Subsequent to filling of the colon with a gadolinium-water mixture under MRI-monitoring, 3D-data sets of the colon were acquired in prone and supine positions over a 28 sec breathold interval. Subsequently multiplanar T{sub 1}-weighted 2D-sequences were acquired before and following i.v. administration of Gd-DTPA (0.1 mmol/kg BW). All imaging was performed in the coronal orientation. The 3D-data were interactively analysed based on various displays: Maximum intensity projection (MIP), surface shadowed display (SSD), multiplanar reconstruction (MPR), virtual colonoscopy (VC). Results: All ...

1997-09-01

19

Three-dimensional rotational angiography of the carotid arteries with high-flow injection from the aortic arch. Preliminary experience  

International Nuclear Information System (INIS)

Purpose: Three-dimensional rotational angiography (3DRA) is a new technique based on a rotational angiographic acquisition able to display arterial vessels in a 3D rendering mode. The system was mainly developed for neuroradiological evaluations but preliminary extracranial experiences have also been reported. The aim of our work was to compare the results of three-dimensional angiography of the carotid arteries done with high-flow injection of contrast medium from the aortic arch with the results of selective angiography. Materials and methods: Twenty patients underwent digital angiography of the supra-aortic vessels in order to quantify a stenosis of the carotid bifurcations previously detected at Doppler Ultrasound. Examinations were performed with the Philips Integris Allura system provided with the rotational angiography (RA) tool connected to a workstation for three-dimensional reconstruction able to display vessels ...

20

JAtlasView: a Java atlas-viewer for browsing biomedical 3D images and atlases  

UK PubMed Central (United Kingdom)

BackgroundMany three-dimensional (3D) images are routinely collected in biomedical research and a number of digital atlases with associated anatomical and other information have...Full Text Available

21

Automated 3-D method for the correction of axial artifacts in spectral-domain optical coherence tomography images  

UK PubMed Central (United Kingdom)

The 3-D spectral-domain optical coherence tomography (SD-OCT) images of the retina often do not reflect the true shape of the retina and are distorted differently along the x and y...Full Text Available

22

Stereotactic Radiation Therapy for Brain Tumors  

Medline Plus

... acquired, which we then volumetrically fuse with the 3D image set from the MR. And by doing ...

23

Comprehensive Quantification of Signal-to-Noise Ratio and g-Factor for Image-Based and k-Space-Based Parallel Imaging Reconstructions  

UK PubMed Central (United Kingdom)

Parallel imaging reconstructions result in spatially varying noise amplification characterized by the g-factor, precluding conventional measurements of noise from the final...Full Text Available

2008-10-01

24

Diagnosis for the cancer extension of cholangiocarcinoma. The current status  

International Nuclear Information System (INIS)

Described is the diagnosis for the cancer extension of cholangiocarcinoma by various imaging techniques and processes to support the current surgical procedure based on preoperative biliary drainage. The cancer tends to locally extend horizontally and/or vertically and its diagnosis is important for surgical indication. For the indication, multi-detector raw CT (MDCT) and MR cholangio-pancreatography (MRCP) are useful and particularly, the former can give multi-phase (arterial, portal and delayed) images to reconstruct multiplanar (MPR) and CT angiographic 3D images, which have made the previous invasive examinations like angiography and percutaneous transportal contrasting unnecessary. MDCT and MRCP can almost complete the diagnosis of the extension. The operative procedure is decided dependently on the site of the lesion, and of which diagnosis, whether it is ...

2010-07-01

25

(Hadamard transform imaging)  

Science.gov (United States)

This report describes the design of, and image reconstruction capacity of a Hadamard Raman Microscopic imager. Microscopy of benzoic acid and graphite electrodes, as well as electrophoretic blotting, are described. (CBS)

1990-01-01

26

Introduction to Three Dimensional Reconstruction of Brain C. T. Image  

International Nuclear Information System (INIS)

The reconstruction of coronal and Sagittal Image of Brain C. T. is helpful to diagnosis of Brain. Three Dimensional Reconstruction software package allows to display three dimensional Image clerived from a series of Horizontal, Sagittal and Coronal Brain C. T. images. It useful in determine approach of operation, to define portals of deep radiation therapy.

1986-11-01

27

3D rotational angiography: Benefits obtained in clinical endovascular treatments  

International Nuclear Information System (INIS)

The application of 3D rotational angiography marks a breakthrough in endovascular treatment of aneurysmas of the brain. 3D images are produced based on image series obtained by rotational angiography, so that the anatomic details of interest can be visualized from any requested angle. (orig./CB)

1999-01-01

28

Visualization and volumetric structures from MR images of the brain  

Energy Technology Data Exchange (ETDEWEB)

Pinta is a system for segmentation and visualization of anatomical structures obtained from serial sections reconstructed from magnetic resonance imaging. The system approaches the segmentation problem by assigning each volumetric region to an anatomical structure. This is accomplished by satisfying constraints at the pixel level, slice level, and volumetric level. Each slice is represented by an attributed graph, where nodes correspond to regions and links correspond to the relations between regions. These regions are obtained by grouping pixels based on similarity and proximity. The slice level attributed graphs are then coerced to form a volumetric attributed graph, where volumetric consistency can be verified. The main novelty of our approach is in the use of the volumetric graph to ensure consistency from symbolic representations obtained from individual slices. In this fashion, the system allows errors to be made at the slice level, yet ...

1994-03-01

29

Die Backside FIB Preparation for Identification and Characterization of Metal Voids  

Energy Technology Data Exchange (ETDEWEB)

Both the increased complexity of integrated circuits, resulting in six or more levels of integration, and the increasing use of flip-chip packaging have driven the development of integrated circuit (IC) failure analysis tools that can be applied to the backside of the chip. Among these new approaches are focused ion beam (FIB) tools and processes for performing chip edits/repairs from the die backside. This paper describes the use of backside FIB for a failure analysis application rather than for chip repair. Specifically, they used FIB technology to prepare an IC for inspection of voided metal interconnects (lines) and vias. Conventional FIB milling was combined with a super-enhanced gas assisted milling process that uses XeF{sub 2} for rapid removal of large volumes of bulk silicon. This combined approach allowed removal of the TiW underlayer from a large number of Ml lines simultaneously, enabling rapid localization and plan view imaging of voids in lines and ...

1999-07-28

30

3-D prestack migration in anisotropic media  

Energy Technology Data Exchange (ETDEWEB)

A three-dimensional (3-D) prestack reverse-time migration algorithm for common-source P-wave data from anisotropic media is developed and illustrated by application to synthetic data. Both extrapolation of the data and computation of the excitation-time imaging condition are implemented using a second-order finite-difference solution of the 3-D anisotropic scalar-wave equation. Poorly focused, distorted images are obtained if data from anisotropic media are migrated using isotropic extrapolation; well focused, clear images are obtained using anisotropic extrapolation. A priori estimation of the 3-D anisotropic velocity distribution is required. Zones of anomalous, directionally dependent reflectivity associated with anisotropic fracture zones are detectable in both the ...

1993-01-01

31

Ct3d: tracking microglia motility in 3D using a novel cosegmentation approach  

UK PubMed Central (United Kingdom)

Motivation: Cell tracking is an important method to quantitatively analyze time-lapse microscopy data. While numerous methods and tools exist for tracking cells in 2D time-lapse images,...Full Text Available

2011-02-15

32

Catheter Ablation for Paroxysmal Atrial Fibrillation  

Medline Plus

... catheter ablation for paroxysmal atrial fibrillation procedure utilizing 3-D mapping and rotational intracardiac echocardiography. This program is ... of the MRI scan and then there's the 3-D image, which is generated from the pixels chosen ...

33

Accuracy of Contacts Calculated from 3D Images of Occlusal Surfaces  

UK PubMed Central (United Kingdom)

ObjectiveCompare occlusal contacts calculated from 3D virtual models created from clinical records to contacts identified clinically using shimstock and transillumination.Full Text Available

2007-06-01

34

A frequency-based approach to locate common structure for 2D-3D intensity-based registration of setup images in prostate radiotherapy  

UK PubMed Central (United Kingdom)

In many radiotherapy clinics, geometric uncertainties in the delivery of 3D conformal radiation therapy and intensity modulated radiation therapy of the prostate are reduced by aligning the...Full Text Available

2007-07-01

35

Three-Dimensional Wing Kinematics and Aerodynamic Characteristics of a Beetle in Free Flight  

Science.gov (United States)

Detailed three dimensional wing kinematics and aerodynamic characteristics are experimentally presented for the free flight of a beetle, Allomyrina dichotoma, which has a pair of elytra (fore wings) and hind wings. The kinematic parameters of the wing motion, such as the wing tip trajectory, angle of attack, torsion angle, and camber deformation, are obtained from a 3D reconstruction technique that involves the use of two or three synchronized high-speed cameras to digitize various points marked on the wings. Our data show outstanding characteristics of wing deformation and flexibility in the free flight of the beetle. To find out the mechanism of aerodynamic force, the leading edge vortex (LEV) and trailing edge vortex (TEV) on both elytron and hind wing were observed by using smoke wire visualization and digital particle image velocimetry (DPIV) technique. Qualitative smoke lines in the region of the ...

2010-11-01

36

Iterative Dense Correspondence Correction Through Bundle Adjustment Feedback-Based Error Detection  

Energy Technology Data Exchange (ETDEWEB)

A novel method to detect and correct inaccuracies in a set of unconstrained dense correspondences between two images is presented. Starting with a robust, general-purpose dense correspondence algorithm, an initial pose estimate and dense 3D scene reconstruction are obtained and bundle-adjusted. Reprojection errors are then computed for each correspondence pair, which is used as a metric to distinguish high and low-error correspondences. An affine neighborhood-based coarse-to-fine iterative search algorithm is then applied only on the high-error correspondences to correct their positions. Such an error detection and correction mechanism is novel for unconstrained dense correspondences, for example not obtained through epipolar geometry-based guided matching. Results indicate that correspondences in regions with issues such as occlusions, repetitive patterns and moving objects can be identified and ...

2009-11-23

37

Accurate positioning for head and neck cancer patients using 2D and 3D image guidance  

UK PubMed Central (United Kingdom)

Our goal is to determine an optimized image-guided setup by comparing setup errors determined by two-dimensional (2D) and three-dimensional (3D) image guidance for head and neck cancer (HNC)...Full Text Available

38

Study of spatial resolution in three-dimensional rotational angiography  

International Nuclear Information System (INIS)

In interventional radiology (IVR) of cerebral aneurysms, it is important to understand the form and physical relationships between the cerebral aneurysm and the surrounding vessels. However, because the vessels in the head area are highly complex, it can be difficult to comprehend the structure using conventional angiography. Therefore, three-dimensional rotational angiography (3D-RA) has been used in recent years. This article discusses studies of the spatial resolution of 3D-RA. We reconstructed 3D-RA of an acrylic slit phantom (slit widths: 0.5, 0.75, 1.0, 1.5 mm) and examined spatial resolution by visual evaluation and profile curves. When the slit phantom was arranged to avoid the effect of beam hardening, the spatial resolution of 3D-RA was found to be as high as 0.75 mm. When the slit phantom ...

2006-03-01

39

A new method of imaging particle tracks in solid state nuclear track detectors  

British Library Electronic Table of Contents (United Kingdom)

Summary Solid state nuclear track detectors are used to determine the concentration of a particles in the environment. The standard method for assessing exposed detectors involves 2D image analysis. However 3D imaging has the potential to provide additional information relating to angle as well as to differentiate clustered hit sequences and possibly energy of a particles but this could be time consuming. Here we describe a new method for rapid high-resolution 3D imaging of solid state nuclear track detectors. A `LEXT' OLS3100 confocal laser scanning microscope (Olympus Corporation, Tokyo, Japan) was used in confocal mode to successfully obtain 3D image data on four CR-39 plastic detectors. Three-dimensional visualization and image analysis enabled ...

2010-01-01

40

TIME EVOLUTION OF CORONAL MAGNETIC HELICITY IN THE FLARING ACTIVE REGION NOAA 10930  

International Nuclear Information System (INIS)

To study the three-dimensional (3D) magnetic field topology and its long-term evolution associated with the X3.4 flare of 2006 December 13, we investigate the coronal relative magnetic helicity in the flaring active region (AR) NOAA 10930 during the time period of December 8-14. The coronal helicity is calculated based on the 3D nonlinear force-free magnetic fields reconstructed by the weighted optimization method of Wiegelmann, and is compared with the amount of helicity injected through the photospheric surface of the AR. The helicity injection is determined from the magnetic helicity flux density proposed by Pariat et al. using Solar and Heliospheric Observatory/Michelson Doppler Imager magnetograms. The major findings of this study are the following. (1) The time profile of the coronal helicity shows a good correlation with that of the helicity accumulation ...

2010-09-10

41

Initiation of conformal radiotherapy with a multileaf-collimator - An approach to clinical routine  

International Nuclear Information System (INIS)

The implementation of a three-dimensional conformal radiotherapy facility in the radiotherapy department of the Heinrich Heine University is described. Complex radiotherapy techniques with commercially available networked systems are introduced to improve clinical work. Over 18 month we have gained clinical experience with a PHILIPS Multileaf Collimator (MLC) mounted on a SL 25 linear accelerator. For a limited period the MLC was used as a conventional blocking device. The standard MLC-shapes are controlled with a stand-alone computer system. In addition, a three-dimensional treatment planning system (3-D-TPS / TMS-Radix, Helax AB) based on convolution/superposition algorithms was recently installed. Treatment optimization is achieved using static field arrangements with complete volumetric computerized tomographic patient data for 3-D-TPS. Conformal adaptation of the 95%-isodose to the Planning Target ...

1995-10-01

42

Diagnosis of occipital condyle fractures; Diagnostik von Frakturen der Okzipitalkondylen  

Energy Technology Data Exchange (ETDEWEB)

Following the conventional X-ray diagnosis of the skull and upper cervical spine, CT proved to be the primary diagnostic method after a skull and brain injury: For all 4 cases we succeeded in detecting the occipital condyle fracture and in determing its size and location by reconstructions (coronal, sagittal, 3-D). In the case of complex occompanying injuries like soft tissue hematomas (cerebral, in the spinal cord, and the soft tissue of the neck) or for the detection of brain stem contusion, MRT had significant advantages. MRT can offer a higher image quality in soft tissue, especially in the spinal cord and the brain. (orig.) [Deutsch] Im Anschluss an die konventionelle Roentgendiagnostik des Schaedels und der Halswirbelsaeule, erwies sich die Computertomographie als primaer einzusetzendes diagnostisches Verfahren, nach erlittenem Schaedel-Hirn-Trauma. In allen Faellen gelang der exakte ...

1995-01-01

43

A BPF-FBP tandem algorithm for image reconstruction in reverse helical cone-beam CT  

UK PubMed Central (United Kingdom)

Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image...Full Text Available

2010-01-01

44

Reconstructions of archaeological contexts in OpenGl environments; Intelligenza artificiale per i beni culturali e le biblioteche digitali. Atti del Workshop  

Energy Technology Data Exchange (ETDEWEB)

DVR project concerns the creation of a virtual reality OpenGL system for desktop applications in archaeology. The main goal is the creation of a 3D information system using the real time interaction of OpenGL environments. The first case study implemented is the Vettii House, one of the most important and outstanding monuments in Pompei. The virtual reconstruction of these architectural models is based on very detailed photogrammetric surveys and it is connected with information layers and archaeometric data-bases regarding the state of conservation of walls, structures and any type of materials of the monument. A full 3D interface characterizes the system, comprising a high resolution texturing with detailed volumetric and geometric data. Finally, for the future, the project plans to fit the system for scientific and end users through the installation of stations on site.

2001-07-01

45

Injuries of the tibio-talar joint and preoperative planning. Verletzungen des oberen Sprunggelenks aus unfallchirurgischer Sicht  

Energy Technology Data Exchange (ETDEWEB)

The treatment of bony, osteochondral, and ligamentous injuries of the tibio-talar requires precise preoperative planning by radiological investigation. This is essential to a correct understanding of the underlying pathology and will allow a proper classification of the injury, which is the basis of treatment. Conventional radiography using anteroposterior and lateral X-rays with comparative views of the noninjured side and, if necessary, rotated spot views and tomography are of high value especially in osteochondral fractures of the talus. Intraoperative control images in both planes after osteosynthesis are mandatory. For evaluation of the postoperative course and severity of arthrosis formation, the classification system of Bargon has proved its worth. In addition, tomography of the tibio-talar joint in two planes is useful especially in tibial pilon fractures, some malleolar fractures, and peripheral talar fractures. In talar fracture dislocations with ...

1991-12-01

46

Importance of preoperative imaging with 64-row three-dimensional multidetector computed tomography for safer video-assisted thoracic surgery in lung cancer  

British Library Electronic Table of Contents (United Kingdom)

Purpose Video-assisted thoracic surgery (VATS) has recently been adopted for complicated anatomical lung resections. During these thoracoscopic procedures, surgeons view the operative field on a two-dimensional (2-D) video monitor and cannot palpate the organ directly, thus frequently encountering anatomical difficulties. This study aimed to estimate the usefulness of preoperative three-dimensional (3-D) imaging of thoracic organs. Methods We compared the preoperative 64-row three-dimensional multidetector computed tomography (3DMDCT) findings of lung cancer-affected thoracic organs to the operative findings. Results In comparison to the operative findings, the branches of pulmonary arteries, veins, and bronchi were well defined in the 3D-MDCT images of 27 patients. Conclusion 3D-MDCT imag...

2009-01-01

47

A study of reconstruction algorithms and filters for an industrial X-ray tomography system  

Energy Technology Data Exchange (ETDEWEB)

Computed tomography (CT) has been incorporated in an industrial Diode-Array Digital Radiography (DADR) system. An input data size of 512 pixel points x 400 projections yielded a 400x400 output image matrix. Reconstruction algorithms used are the filtered backprojection (FBP) and the direct Fourier reconstruction (DFR). Various filters were used in the FBP reconstruction process and their effects on image quality were evaluated. A spatial resolution of 100 {mu}m was measured with a block of plates and a minimum detectable feature size in the range of 10-100 {mu}m was measured using thin wires. Industrial specimens imaged have included ceramic samples, ball bearings and integrated circuits. A number of engineering problems have been solved, such as adjustment of the X-ray source, centering of the rotator spindle in the view field and beam-hardening corrections. ...

1990-12-20

48

Semi-automated segmentation of the sigmoid and descending colon for radiotherapy planning using the fast marching method  

International Nuclear Information System (INIS)

A fast and accurate segmentation of organs at risk, such as the healthy colon, would be of benefit for planning of radiotherapy, in particular in an adaptive scenario. For the treatment of pelvic tumours, a great challenge is the segmentation of the most adjacent and sensitive parts of the gastrointestinal tract, the sigmoid and descending colon. We propose a semi-automated method to segment these bowel parts using the fast marching (FM) method. Standard 3D computed tomography (CT) image data obtained from routine radiotherapy planning were used. Our pre-processing steps distinguish the intestine, muscles and air from connective tissue. The core part of our method separates the sigmoid and descending colon from the muscles and other segments of the intestine. This is done by utilizing the ability of the FM method to compute a specified minimal energy functional integrated along a path, and thereby extracting the colon ...

2010-09-21

49

On the accuracy and effectiveness of dose reconstruction for tomotherapy  

International Nuclear Information System (INIS)

Dose reconstruction is a process that re-creates the treatment-time dose deposited in a patient provided there is knowledge of the delivered energy fluence and the patient's anatomy at the time of treatment. A method for reconstructing dose is presented. The process starts with delivery verification, in which the incident energy fluence from a treatment is computed using the exit detector signal and a transfer matrix to convert the detector signal to energy fluence. With the verified energy fluence and a CT image of the patient in the treatment position, the treatment-time dose distribution is computed using any model-based algorithm such as convolution/superposition or Monte Carlo. The accuracy of dose reconstruction and the ability of the process to reveal delivery errors are presented. Regarding accuracy, a reconstructed dose distribution was compared with a measured film ...

2001-04-01

50

Chapter 14: Seismic imaging using 2- and 3-D migration  

Energy Technology Data Exchange (ETDEWEB)

Development of a number of original 3-D migration methods and algorithms is described. The computational efficiency of these algorithms is demonstrated by implementing them on vector and parallel supercomputers. Two-dimensional post-stack and pre-stack depth migration algorithms in the frequency - space domain using implicit finite difference method were also developed and implemented on a parallel computer, and adapted for applications that range from deep crustal imaging of seismic wavefields that involve wide ranging travel times and frequencies. All implicit finite difference migration algorithms were highly prallelized . The one pass 3-D post-stack depth migration algorithm was extensively used for imaging of seismic monitoring data from Cold Lake, Alberta. Experience shows that it provides the right trade-off between accuracy and computational efficiency. ...

1999-09-01

51

Near-surface 3D reflections seismic survey; Sanjigen senso hanshaho jishin tansa  

Energy Technology Data Exchange (ETDEWEB)

Faults are being actively investigated across Japan since the Great Hanshin-Awaji Earthquake. Discussed in this report is the application of the 3D near-surface reflection seismic survey in big cities. Data from trenching and drilling is used for the geological interpretation of the surroundings of a fault, and the reflection seismic survey is used to identify the position, etc., of the fault. In this article, when the results obtained from the experimental field are examined, it is found that the conventional 2D imaging reflection survey betrays the limit of its capability when the geological structure is complicated, that the 3D reflection seismic survey, on the contrary, is capable of high-precision imaging and, when augmented by drilling, etc., becomes capable of a more detailed interpretation, and that it also contributes effectively to the improvement of ...

1997-05-27

52

A non-uniformly sampled 4D HCC(CO)NH-TOCSY experiment processed using maximum entropy for rapid protein sidechain assignment  

Science.gov (United States)

One of the stiffest challenges in structural studies of proteins using NMR is the assignment of sidechain resonances. Typically, a panel of lengthy 3D experiments are acquired in order to establish connectivities and resolve ambiguities due to overlap. We demonstrate that these experiments can be replaced by a single 4D experiment that is time-efficient, yields excellent resolution, and captures unique carbon-proton connectivity information. The approach is made practical by the use of non-uniform sampling in the three indirect time dimensions and maximum entropy reconstruction of the corresponding 3D frequency spectrum. This 4D method will facilitate automated resonance assignment procedures and it should be particularly beneficial for increasing throughput in NMR-based structural genomics initiatives.

2010-05-01

53

Evaluation of fetal brain development by magnetic resonance imaging. Subependymal germinal matrix layer and cerebral ventricle  

International Nuclear Information System (INIS)

Three dimensional data of brain from the formalin-fixed fetuses were collected without isolation, by the 4.7 tesla super high magnetic field MRI and the developmental process of the cerebral parenchyma was studied by 3D images. Subjects were 13 fetal brain and MRI was performed using 3D-steady-state free precession sequence. The isolated brain is very soft and fragile and is deformed by its weight at the imaging. However 3D-MRI can be obtained without isolation, and the deformation is remarkably small. The subependymal germinal matrix layer did not be observed in 7 weeks-old fetus, appeared at 9 weeks-old and increased gradually. Then it rapidly reduced from 28 weeks-old. The volume calculated, from 3D-MRI, increased rapidly from 9 weeks-old to 23 weeks-old, and reached the ...

1999-10-01

54

Soft x-ray microradiography and lithograph using a laser produced plasma source. Final report  

Energy Technology Data Exchange (ETDEWEB)

Considering the hardware characteristics of the laser-induced plasma X-ray source and the limitations of the conventional cone-beam reconstruction algorithm, a general cone-beam reconstruction algorithm has been developed at our laboratory, in which the motion locus of the X-ray source is an arbitrary curve corresponding to at least a 2{pi} continuous horizontal angular displacement in the coordinate system of the specimen. The preliminary simulation shows that the general cone-beam reconstruction algorithm consistently results in visually satisfactory images.

1992-03-01

55

Soft x-ray microradiography and lithograph using a laser produced plasma source  

Energy Technology Data Exchange (ETDEWEB)

Considering the hardware characteristics of the laser-induced plasma X-ray source and the limitations of the conventional cone-beam reconstruction algorithm, a general cone-beam reconstruction algorithm has been developed at our laboratory, in which the motion locus of the X-ray source is an arbitrary curve corresponding to at least a 2{pi} continuous horizontal angular displacement in the coordinate system of the specimen. The preliminary simulation shows that the general cone-beam reconstruction algorithm consistently results in visually satisfactory images.

1992-01-01

56

Quantitative analysis of X-Ray Microtomography images of metal powders in the course of sintering  

Energy Technology Data Exchange (ETDEWEB)

In situ X-Ray microtomography offers new opportunities for analysing sintering mechanisms since it allows 3D observation of the microstructural evolution of the powder all along a sintering cycle. With synchrotron radiation at ESRF, a 3D image with a resolution of 2 {mu}m can be obtained in about one minute. In addition to the visual examination of the images, relevant microstructural parameters can be measured through quantitative image analysis using recently developed tools. In this paper the results obtained with two materials, loose copper powder and compacted steel powder, are resumed. For copper powder, the dispersion of local parameters such as particle co-ordination number and porosity is investigated. Concerning steel compacts, data about pore morphology evolution and on local strains provides clues for understanding the ...

2005-07-01

57

Resolution enhancement by subtraction of confocal signals taken at different pinhole sizes.  

Science.gov (United States)

Subtractive imaging in confocal fluorescence light microscopy is based on the subtraction of a suitably weighted widefield image from a confocal image. An approximation to a widefield image can be obtained by detection with an opened confocal pinhole. The subtraction of images enhances the resolution in-plane as well as along the optic axis. Due to the linearity of the approach, the effect of subtractive imaging in Fourier-space corresponds to a reduction of low spatial frequency contributions leading to a relative enhancement of the high frequencies. Along the direction of the optic axis this also results in an improved sectioning. Image processing can achieve a similar effect. However, a 3D volume dataset must be acquired and processed, yielding a result essentially identical to subtractive ...

2003-01-01

58

Synthetic aperture radar image of agricultural fields with surface drainage network: simulation and spatial information retreival  

Science.gov (United States)

We develop a 3-D model to simulate the synthetic aperture radar (SAR) image formation process of an undulated vegetation canopy such as corn grown in fields with large periodic drainage reliefs. We explain how the simulated SAR image of undulated vegetation medium is obtained by the convolution of a 2-D slice of the 3-D simulated SAR system point spread function [(PSF), emulating the SAR beam modeled by a cosine modulated Gaussian], with the 2-D projection of the observed undulated vegetation canopy (modeled with scatterers randomly distributed in 3-D undulated space) followed by the extraction of each look envelope, the summation of looks, and sampling in azimuthal and range directions. Our model is useful to study the parameters involved in the formation and the analysis of SAR images of undulated ...

2001-10-01

59

The different structural scales of the breast and their impact on time-of-flight and diffraction tomography  

Energy Technology Data Exchange (ETDEWEB)

Ultrasound tomography is an attractive imaging method for the detection of breast cancer. The complex anatomy of the breast with its different spatial scales and material property contrasts make accurate reconstructions very challenging. This paper proposes a hybrid approach whereby Travel-of-Flight and Diffraction Tomography are combined together to achieve high-resolution and high-accuracy sound-speed reconstructions. The method is validated with several numerical phantoms.

2010-01-01

60

New real-time MR image-guided surgical robotic system for minimally invasive precision surgery  

Energy Technology Data Exchange (ETDEWEB)

To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using ...

2008-04-15

61

Three-dimensional evaluation of cartilage thickness and cartilage volume in the knee joint with MR imaging: reproducibility in volunteers; Dreidimensionale Dicken- und Volumenbestimmung des Kniegelenkknorpels mit der MRT: Reproduzierbarkeit am Probanden  

Energy Technology Data Exchange (ETDEWEB)

Objective: To determine the reproductibility of three-dimensional volume and thickness measurements of the knee joint cartilage with MRI in volunteers. Methods: The knees of 7 healthy individuals (ages 23 to 58 yrs.) were sagitally imaged with a resolution of 2x0.31x0.31 mm{sup 3}, using a fat-suppressed FLASH-3 D sequence. The knee was repositioned in between replicate acquisitions, 6 data sets being obtained in each case. After semiautomatic segmentation and three-dimensional reconstruction of the cartilage, the thickness was determined independent of the original section orientation. The coefficient of variation for repeated volume measurements and the deviations of the maximal cartilage thickness values were calculated subsequently. Results: The mean variation of the cartilage volumes of the replicate measurements was 1.4% ({+-}0.8%) in the patella, 1.7% ({+-}1.5%) in the femur, 3.0% ({+-}1.2%) in ...

1997-12-01

62

3D time-of-flight MR angiography of the intracranial vessels: optimization of the technique with water excitation, parallel acquisition, eight-channel phased-array head coil and low-dose contrast administration  

Energy Technology Data Exchange (ETDEWEB)

The aim of this study is three folds: to compare the eight-channel phased-array and standard circularly polarized (CP) head coils in visualiazation of the intracranial vessels, to compare the three-dimentional (3D) time-of-flight (TOF) MR angiography (MRA) techniques, and to define the effects of parallel imaging in 3D TOF MRA. Fifteen healthy volunteers underwent 3D TOF MRA of the intracranial vessels using eight-channel phased-array and CP standard head coils. The following MRA techniques were obtained on each volunteer: (1) conventional 3D TOF MRA with magnetization transfer; (2) 3D TOF MRA with water excitation for background suppression; and (3) low-dose (0.5 ml) gadolinium-enhanced 3D TOF MRA with water ...

2004-11-01

63

An integrated Tomographic Gamma Scanning system for non-destructive assay of radioactive waste  

Energy Technology Data Exchange (ETDEWEB)

The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm{sup -3} or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant ...

2007-08-21

64

An integrated Tomographic Gamma Scanning system for non-destructive assay of radioactive waste  

International Nuclear Information System (INIS)

The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm"-"3 or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant applications. ...

2007-08-21

65

Noise suppression in scatter correction for cone-beam CT  

UK PubMed Central (United Kingdom)

Scatter correction is crucial to the quality of reconstructed images in x-ray cone-beam computed tomography (CBCT). Most of existing scatter correction methods assume smooth scatter distributions. The...Full Text Available

2009-03-01

66

Visualization of liquid metal two-phase flow by a real time neutron radiography system  

Energy Technology Data Exchange (ETDEWEB)

In order to understand the detail transient two-phase flow structure, more advanced two-phase flow instrumentation is required. One advanced technique for flow visualization is real-time neutron radiography. Reconstruction method of visualized radiographic image of liquid metal two-phase flow generated by the real-time neutron radiography system is proposed in this paper. Image processing techniques for noise reduction and image enhancement are discussed in detail. (author).

1995-11-01

67

Visualization of liquid metal two-phase flow by a real time neutron radiography system  

International Nuclear Information System (INIS)

In order to understand the detail transient two-phase flow structure, more advanced two-phase flow instrumentation is required. One advanced technique for flow visualization is real-time neutron radiography. Reconstruction method of visualized radiographic image of liquid metal two-phase flow generated by the real-time neutron radiography system is proposed in this paper. Image processing techniques for noise reduction and image enhancement are discussed in detail. (author).

1995-01-01

68

Track Reconstruction and Performance of DRIFT Directional Dark Matter Detectors using Alpha Particles  

CERN Document Server

First results are presented from an analysis of data from the DRIFT-IIa and DRIFT-IIb directional dark matter detectors at Boulby Mine in which alpha particle tracks were reconstructed and used to characterise detector performance--an important step towards optimising directional technology. The drift velocity in DRIFT-IIa was [59.3 +/- 0.2 (stat) +/- 7.5 (sys)] m/s based on an analysis of naturally-occurring alpha-emitting background. The drift velocity in DRIFT-IIb was [57 +/- 1 (stat) +/- 3 (sys)] m/s determined by the analysis of alpha particle tracks from a Po-210 source. 3D range reconstruction and energy spectra were used to identify alpha particles from the decay of Rn-222, Po-218, Rn-220 and Po-216. This study found that (22 +/- 2)% of Po-218 progeny (from Rn-222 decay) are produced with no net charge in 40 Torr CS2. For Po-216 progeny (from Rn-220 decay) the uncharged fraction is (100 +0 ...

2007-01-01

69

Real-time neutron coded aperture imaging: A technique for nondestructive three-dimensional imaging  

Energy Technology Data Exchange (ETDEWEB)

Neutron Coded Aperture Imaging is a nondestructive imaging technique that utilizes neutrons scattered from an object through specially designed apertures. Coded Aperture Imaging is an alternative technique to Computed Tomography for three-dimensional imaging. Coded Aperture Imaging has the advantage that all of the three-dimensional information is contained in a single image, whereas Computed Tomography requires several images or projections. This technique has been implemented by other using photographic film as an image recording medium and optical reconstruction or decoding of the images. In this work, the possibility of using a real-time neutron video camera to record the images, followed by digital decoding methodology has been investigated. Because only ...

1992-01-01

70

IMRT verification by three-dimensional dose reconstruction from portal beam measurements  

International Nuclear Information System (INIS)

A method of reconstructing three-dimensional, in vivo dose distributions delivered by intensity-modulated radiotherapy (IMRT) is presented. A proof-of-principle experiment is described where an inverse-planned IMRT treatment is delivered to an anthropomorphic phantom. The exact position of the phantom at the time of treatment is measured by acquiring megavoltage CT data with the treatment beam and a research prototype, flat-panel, electronic portal imaging device. Immediately following CT imaging, the planned IMRT beams are delivered using the multiple-static field technique. The delivered fluence is sampled using the same detector as for the CT data. The signal measured by the portal imaging device is converted to primary fluence using an iterative phantom-scatter estimation technique. This primary fluence is back-projected through the previously acquired megavoltage CT model of the phantom, with ...

2002-08-01

71

New MR techniques in diagnostic imaging of joints; Neue MRT-Techniken in der Gelenkdiagnostik  

Energy Technology Data Exchange (ETDEWEB)

Already, MR Imaging is superior in diagnostic imaging of joints in many cases; however, there have been recent developments, which are the subjects of this paper. With gradient-echo sequences acquired in 3D technique, it is possible to produce high-resolution images of joints in acceptable scantime, because gradient-echo sequences are less time-consuming than convential SE sequences. With the acquisition of two echoes, phase difference between water and fat protons have to be considered. 3D Imaging is capable of displaying complex pathology in a superior way, which should be useful in preoperative planning. Tissue contrast is altered by fat saturation or magnetization transfer in order to achieve better conspicuity of lesions. Although diagnostic value of some of these options is not yet clear and further clinical ...

1993-12-31

72

Three-dimensional image display of brain tumor utilizing a modified voxel method  

Energy Technology Data Exchange (ETDEWEB)

The patch and voxel methods are representative examples of the ways in which multi-slice images may be displayed three-dimensionally by means of computer-graphics. Each of them have advantages and disadvantages and they are mutually complementary. We have developed algorithms for a modified voxel method which incorporates the advantages of the patch methods. We have applied this to the three-dimensional image display of brain tumor with excellent results. The three-dimensional reconstructions used for clinical application in this study were derived from X-ray CT images.

1988-08-01

73

Imaging of reflection seismic and radar wavefields: Monitoring of steam-heated oil reservoirs and characterization of nuclear waste repositories  

Energy Technology Data Exchange (ETDEWEB)

A new three-dimensional (3D) acoustic modelling method was developed using a first-order hyperbolic wave system which was solved with explicit finite dfferences. The numerical solution of the 3D wave system provides a useful method for simulating evolution of a pressure field corresponding to compressional type waves. Existing two-dimensional (2D) elastic modelling algorithms were modified and fine-tuned for computationally efficient and realistic wave propagation simulations in complex structures. An original formulation of the 3D reverse time migration method was developed which is very accurate, does not suffer from unwanted evenescent energy, can image dips beyond 90{degree}, and does not generate multiple energy. Two case studies were performed that involved steam stimulation projects in the Cold Lake deposit. Simulations were performed ...

1994-12-31

74

High-resolution magnetic resonance imaging: three-dimensional trabecular bone architecture and biomechanical properties.  

Science.gov (United States)

The purpose of this study was to use high-resolution magnetic resonance (MR) imaging combined with image analysis to investigate the three-dimensional (3D) trabecular structure, anisotropy, and connectivity of human vertebral, femoral, and calcaneal specimens. The goal was to determine whether: (a) MR-derived measures depict known skeletal-site-specific differences in architecture and orientation of trabeculae; (b) 3D architectural parameters combined with bone mineral density (BMD) improve the prediction of the elastic modulus using a fabric tensor formulation; (c) MR-derived 3D architectural parameters combined with BMD improve the prediction of strength using a multiple regression model, and whether these results corresponded to the results obtained using higher resolution depictions of trabecular architecture. A ...

1998-05-01

75

Native Synthetic Imaging of Smoothed Particle Hydrodynamics density fields using gridless Monte Carlo Radiative Transfer  

CERN Document Server

An algorithm for creating synthetic telescope images of Smoothed Particle Hydrodynamics (SPH) density fields is presented, which utilises the adaptive nature of the SPH formalism in full. The imaging process uses Monte Carlo Radiative Transfer (MCRT) methods to model the scattering and absorption of photon packets in the density field, which then exit the system and are captured on a pixelated image plane, creating a 2D image (or a 3D datacube, if the photons are also binned by their wavelength). The algorithm is implemented on the density field directly: no gridding of the field is required, allowing the density field to be described to an identical level of accuracy as the simulations that generated it. Some applications of the method to star and planet formation simulations are presented to illustrate the advantages of this new technique, and suggestions as ...

2010-01-01

76

FADC signal reconstruction for the MAGIC telescope  

Energy Technology Data Exchange (ETDEWEB)

Until April 2007 the Major Atmospheric Gamma ray Imaging Cherenkov (MAGIC) telescope used a 300 MSamples/s flash analog-to-digital converter (FADC) system to sample the shaped photomultiplier tube (PMT) signals produced by the captured Cherenkov photons of air showers. Different algorithms to reconstruct the signal from the read-out samples (extractors) have been implemented and are described and compared. Criteria based on the obtained charge and time resolution/bias are defined and used to judge the different extractors, by applying them to calibration, cosmic and pedestal signals. The achievable charge and time resolution have been derived as functions of the number of incident photo-electrons.

2008-09-11

77

Evaluation of left ventricular volumes in patients with congenital heart disease and abnormal left ventricular geometry. Comparison of MRI and transthoraic 3-dimensional echocardiography; Vergleich der transthorakalen 3D-Echokardiographie mit der MRT zur Bestimmung linksventrikulaerer Volumina bei Patienten mit pathologischer Ventrikelgeometrie aufgrund angeborener Herzfehler  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To assess the new method of 3-dimensional echocardiography in comparison to the 'gold standard' MRI as to its ability to calculate left ventricular volumes in patients with congenital heart disease. Materials and methods: Eighteen patients between the ages of 3.9 to 37.3 years (mean: 12.8{+-}9.7) with a geometrically abnormal left ventricle were examined using a 1.5 T scanner with a fast gradient-echo sequence (TR=14 ms, TE=2.6-2.9 ms, FOV=300-400 mm, flip angle=20 , matrix=128:256, slice thickness=5 mm, retrospective gating) in multislice-multiphase technique. Transthoracic 3D-echocardiography was performed with a 3.5 MHz transducer and a Tomtec {sup trademark} (Munich, Germany) system for 3D reconstruction. Results: Volume calculation was possible in all patients with 3D-echocardiography, but the muscle mass ...

2003-07-01

78

Synthesis of [3,3-D[sub 2  

Energy Technology Data Exchange (ETDEWEB)

The synthesis of [3, 3-D[sub 2

1993-01-01

79

Hard x-ray phase imaging using simple propagation of a coherent synchrotron radiation beam  

International Nuclear Information System (INIS)

Particularly high coherence of the x-ray beam is associated, on the ID19 beamline at ESRF, with the small angular size of the source as seen from a point of the sample (0.1-1 #mu#rad). This feature makes the imaging of phase objects extremely simple, by using a 'propagation' technique. The physical principle involved is Fresnel diffraction. Phase imaging is being simultaneously developed as a technique and used as a tool to investigate light natural or artificial materials introducing phase variations across the transmitted x-ray beam. They include polymers, wood, crystals, alloys, composites or ceramics, exhibiting inclusions, holes, cracks, ... . 'Tomographic' three-dimensional reconstruction can be performed with a filtered back-projection algorithm either on the images processed as in attenuation tomography, or on the phase maps retrieved from the images with a ...

1999-05-21

80

Application research on three-dimensional virtual mine in the framework of internet of things  

British Library Electronic Table of Contents (United Kingdom)

Based on the information system characteristics of mine, proposed network architecture design of the mine property. And in this framework based on the design of three-dimensional virtual mine described the application of intelligent management platform. Three-dimensional virtual underground mine that shows the situation, the core application is through remote monitoring system of information exchange between devices (material object communication). Internet of things in the framework of mining three-dimensional virtual reconstruction of mine. On coal mine safety in the production process of human, machine and environment, control elements and their harmony and unity. 3D virtual mine management platform integrates personnel positioning, dust control, gas monitoring, roof pressure monitoring...

2011-01-01

81

Magnetic resonance imaging of the pediatric brain  

International Nuclear Information System (INIS)

The atlas presents sequences of MRI sections parallel to the orbito-meatal plane in children from birth through the age of sixteen years. Each child was studied horizontally and sagitally and three-dimensional brain images were reconstructed to facilitate accurate identification of sulci and gyri. The images show crucial aspects of brain development such as the constancy of the brain stem and primitive brain from birth onward; the development of the telencephalon, characterized by deepening of sulci and growth of the cerebral cortex surface; and the different stages of white matter myelinization.

82

Imaging Automation and Volume Tomographic Visualization at Texas Neutron Imaging Facility  

Energy Technology Data Exchange (ETDEWEB)

A thermal neutron imaging facility for real-time neutron radiography and computed tomography has been developed at the University of Texas reactor. The facility produced good-quality radiographs and two-dimensional tomograms. Further developments have been recently accomplished. A computer software has been developed to automate and expedite the data acquisition and reconstruction processes. Volume tomographic visualization using Interactive Data Language (IDL) software has been demonstrated and will be further developed. Volume tomography provides the additional flexibility of producing slices of the object using software and thus avoids redoing the measurements.

1999-11-14

83

Application of the neutron television fluoroscopic system to neutron computed tomography  

Energy Technology Data Exchange (ETDEWEB)

Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter. (orig.).

1984-10-01

84

Application of the neutron television fluoroscopic system to neutron computed tomography  

Energy Technology Data Exchange (ETDEWEB)

Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter.

1984-10-01

85

An application of the neutron television fluoroscopic system to neutron computed tomography  

International Nuclear Information System (INIS)

Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter. (orig.).

1984-10-01

86

Inlay-onlay grafting for three-dimensional reconstruction of the posterior atrophic maxilla with mandibular bone  

British Library Electronic Table of Contents (United Kingdom)

This prospective study describes and evaluates a surgical approach for 3D reconstruction of the posterior maxilla with autogenous mandibular bone in 16 patients (mean age 51 years). Bone blocks were harvested from the mandible and used as lateral or vertical block grafts (onlay); they were also partially milled and used for sinus elevation (inlay). In 4 cases, anorganic bovine bone was added at the periphery of the blocks. 4 months after grafting, implants were placed in a second operation and loaded after 12 weeks. Lateral and vertical augmentations were measured immediately after grafting and at re-entry for implant placement. Mean lateral augmentation performed was 5.5mm, reduced to 4.3mm (p<0.01) after 4 months' healing. Mean vertical augmentation was 3.2mm, reduced to 2.1mm (p<0.01) a...

2010-01-01

87

Introducing DeBRa: a detailed breast model for radiological studies  

Energy Technology Data Exchange (ETDEWEB)

Currently, x-ray mammography is the method of choice in breast cancer screening programmes. As the mammography technology moves from 2D imaging modalities to 3D, conventional computational phantoms do not have sufficient detail to support the studies of these advanced imaging systems. Studies of these 3D imaging systems call for a realistic and sophisticated computational model of the breast. DeBRa (Detailed Breast model for Radiological studies) is the most advanced, detailed, 3D computational model of the breast developed recently for breast imaging studies. A DeBRa phantom can be constructed to model a compressed breast, as in film/screen, digital mammography and digital breast tomosynthesis studies, or a non-compressed breast as in positron emission mammography and breast CT ...

2009-07-21

88

Recent progress in energy-filtered high energy X-ray photoemission electron microscopy using a Wien filter type energy analyzer  

International Nuclear Information System (INIS)

Energy-filtered X-ray photoemission electron microscopy (EXPEEM) is a microscopy technique which has the potential to provide surface chemical mapping during surface chemical processes on the nanometer scale. We studied the possibilities of EXPEEM using a Wien filter type energy analyzer in the high energy X-ray region above 1000 eV. We have successfully observed the EXPEEM images of Au islands on a Ta sheet using Au 3d_5_/_2 and Ta 3d_5_/_2 photoelectron peaks which were excited by 2380 eV X-rays emitted from an undulator (BL2A) at Photon Factory. Our recent efforts to improve the sensitivity of the Wien filter energy analyzer will also be discussed.

2004-10-15

89

Parallel MRI reconstruction using variance partitioning regularization  

British Library Electronic Table of Contents (United Kingdom)

Multiple receivers can be utilized to enhance the spatiotemporal resolution of MRI by employing the parallel imaging technique. Previously, we have reported the L-curve Tikhonov regularization technique to mitigate noise amplification resulting from the geometrical correlations between channels in a coil array. Nevertheless, one major disadvantage of regularized image reconstruction is lengthy computational time in regularization parameter estimation. At a fixed noise level, L-curve regularization parameter estimation was also found not to be robust across repetitive measurements, particularly for low signal-to-noise ratio (SNR) acquisitions. Here we report a computationally efficient and robust method to estimate the regularization parameter by partitioning the variance of the noise-white...

2007-01-01

90

The influence of different SPECT reconstruction algorithms on cardiac ischemia with the use artificial neural networks  

International Nuclear Information System (INIS)

The aim of the study was the attempt to evaluate the influence of two different methods of cardiac perfusion SPECT reconstruction (FBP and ITW) on clinical efficacy in diagnosing the coronary artery disease as well as the cardiac ischemia detection in three areas of heart vascularized by main coronary arteries: LAD, LCX and RCA with the use of artificial neural networks (ANN). The study was performed retrospectively with the use of the diagnostic image records as well as clinical dataset of 43 patients. Myocardial perfusion stress/rest SPECT study and X-ray coronarography data were evaluated for each patient. The results of coronary angiography were considered the reference method. The cardiac SPECT data were reconstructed using the two different methods: filtered backprojection (FBP) and iterative Wallis method (ITW). The local perfusion deficits denominated in stress and rest study in three main vessel cardiac segments ...

91

Photoacoustic imaging using an ultrasonic Fresnel zone plate transducer  

International Nuclear Information System (INIS)

A photoacoustic (PA) imaging system based on an ultrasonic Fresnel zone plate (FZP) transducer is developed for the purpose of imaging biological tissue. This FZP transducer has a two-zone negative zone plate piezoelectric material pattern, and an optical fibre is integrated with the transducer on the symmetric axis of the zone plates to deliver laser pulses to the sample. The focal characteristic of the FZP transducer is analysed by theoretical prediction and experimental measurement, and the measured results are in good agreement with the predicted results. The limited-field back-projection deconvolution algorithm combined with the coherence-factor weighting technique is used to reconstruct the optical absorption distribution. The experiments were performed with phantoms and the blood vessels of chicken embryo chorioallantoic membrane. The results demonstrate that PA imaging using the FZP transducer ...

2008-05-07

92

A three-dimensional display system for brain CT images  

International Nuclear Information System (INIS)

Commercially available CT devices reconstruct cross-sectional slices of the human body. A sequence of such abutting cross-sectional slices can be, and usually is, used to obtain information about the region of the head, which requires several slices to cover it. However, there are situations for which such asequence of displays is far from optimal - for example, when one would like to see the anatomic relationship between two features appearing in different slices or the shape of a particular region or tumor. The Computer Aided Three-Dimensional Reconstruction and Imaging System (CATRIS), developed at our university, can build up a three-dimensional image from a series of CT cross-sections and can display its stereoscopic image on a three-dimensional graphic display system, thus providing helpful information for clinical use in recognizing the anatomic relationship between two ...

93

Determination of cartilage thickness in the ankle joint. MRT (1,5 T) comparative anatomical study; Bestimmung der Knorpeldicke am oberen Sprunggelenk. Eine MRT(1,5 T)-anatomische Vergleichsstudie  

Energy Technology Data Exchange (ETDEWEB)

Purpose: The aim of this study was to evaluate the accuracy of MRI in the measurement of cartilage thickness of the ankle joint in comparison to pathologic and histologic specimens. Patients and methods: The ankle joints of four fresh cadaver feet were imaged on a 1.5 T MR-unit in the coronal plane. Standard T{sub 1}-weighted spin echo (SE) and a T{sub 1}-weighted 3D-GE (FLASH-3D) sequence with fat saturation were applied. Following MR imaging, the talus was explanted and cut parallel to the MR images for macroscopic evaluation and histologic specimens were prepared. MRI measurements of the cartilage thickness of the talus were carried out in two ways: Without and with consideration of a transition zone of intermediate signal intensity between hyperintense cartilage and hypointense cortical bone. The data were compared with the anatomic ...

1997-04-01

94

Magnified x-ray phase imaging using asymmetric Bragg reflection: Experiment and theory  

International Nuclear Information System (INIS)

X-ray imaging using asymmetric Bragg reflection in the hard x-ray regime opens the way to improve the spatial resolution limit below 1 #mu#m by magnifying the image before detection, simultaneously providing a strong phase contrast. A theoretical formalism of the imaging process is established. Based on this algorithm, numerical simulations are performed and demonstrate that both Fresnel propagation and Bragg diffraction contribute to contrast formation. The achievable resolution of this technique is investigated theoretically; the results obtained can be used to improve future experimental setups. Furthermore, the minimum detectable phase gradient is estimated, for comparison with other phase sensitive imaging techniques. Results from biological objects demonstrate that the technique is viable for imaging both in two and three dimensions. Refraction contrast ...

2006-08-01

95

Modern visualization of the liver with MRI - current trends and future perspectives; Moderne Leberbildgebung mit der MRT - aktuelle Trends und Zukunft  

Energy Technology Data Exchange (ETDEWEB)

This contribution provides an overview and imparts basic knowledge on pertinent technical developments in magnetic resonance imaging (MRI) of the liver: 3D sequences, respiratory triggering, parallel imaging, and 3 Tesla (3T). 3D sequences can be used as T1-weighted (T1w) sequences for analyzing dynamics of contrast enhancement or as T2w sequences for MR cholangiography. Consistent improvements in respiratory triggering make it possible to obtain good image quality on T2w scans even in patients unable to hold their breath. Parallel imaging as a universal technique to accelerate image acquisition is particularly appropriate for MRI of the liver, and it has been shown that the reduced acquisition time is not achieved at the expense of image quality. Further progress in MRI of the ...

2004-12-01

96

MRI evaluation and image processing in gel dosimetry. A study of selected MRI properties and image processing in 3D gel dosimetry  

Energy Technology Data Exchange (ETDEWEB)

Gel dosimetry is a new dosimetry method applied in radiation therapy. Gel dosimeters consist of a radiation sensitive gel, which can integrate absorbed doses from several radiation sources or beams. The dose to the gel can be evaluated by magnetic resonance imaging (MRI), a procedure that is the focus of the present thesis. A robust tool for the evaluation of the nonuniformity in MRI has been developed, the Deviation Image method. Unlike previously presented methods, the Deviation Image method includes all nonuniformity variations across a phantom surface and is insensitive to stochastic noise. Methods for the estimation of stochastic noise were analyzed in terms of sensitivity to nonuniformities. A method that averages the stochastic noise level over five regions over the phantom surface, and a method that assesses the stochastic noise level from the background, were found to be the methods of choice. Pronounced MR ...

2001-03-01

97

Moxel: A molar tooth voxel model for dosimetric studies  

Energy Technology Data Exchange (ETDEWEB)

Stylized numerical models of the tooth are usually employed in qualification procedure related to Electronic Paramagnetic Resonance in long-term accidental contamination dose reconstruction. In this work a voxel model was developed from the microCT image data set of a human non contaminated molar tooth. A stylized model, reproducing the characteristics of the voxel model, was also created in order to investigate the level of accuracy that can be obtained in this kind of study.

2010-02-15

98

Digital image precessing for neutron television fluoroscopic system and its application to neutron computed tomography  

Energy Technology Data Exchange (ETDEWEB)

The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the ...

1984-09-01

99

Digital image precessing for neutron television fluoroscopic system and its application to neutron computed tomography  

International Nuclear Information System (INIS)

The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the ...

1984-01-01

100

Multi-modality imaging of uveal melanomas using combined PET/CT, high-resolution PET and MR imaging  

Energy Technology Data Exchange (ETDEWEB)

We investigated the efficacy of combined FDG-PET/CT imaging for the diagnosis of small-size uveal melanomas and the feasibility of combining separate, high-resolution (HR) FDG-PET with MRI for its improved localization and detection. Patients, methods: 3 patients with small-size uveal melanomas (0.2-1.5 ml) were imaged on a combined whole-body PET/CT, a HR brain-PET, and a 1.5 T MRI. Static, contrast-enhanced FDG-PET/CT imaging was performed of head and torso with CT contrast enhancement. HR PET imaging was performed in dynamic mode 0-180 min post-injection of FDG. MRI imaging was performed using a high-resolution small-loop-coil placed over the eye in question with T2-3D-TSE and T1-3D-SE with 18 ml Gd-contrast. Patients had their eyes shaded during the scans. Lesion visibility on high-resolution ...

2008-07-01

101

Boxy/peanut "bulges": comparing the structure of galaxies with the underlying families of periodic orbits  

CERN Document Server

The vertical profiles of disc galaxies are built by the material trapped around stable periodic orbits, which form their "skeletons". According to this, the knowledge of the stability of the main families of periodic orbits in appropriate 3D models, can predict possible morphologies for edge-on disc galaxies. In a pilot survey we compare the orbital structures which lead to the appearance of "peanuts" and "X"-like features with the edge-on profiles of three disc galaxies (IC 2531, NGC 4013 and UGC 2048). The subtraction from the images of a model representing the axisymmetric component of the galaxies reveals the contribution of the non-axisymmetric terms. We find a direct correspondence between the orbital profiles of 3D bars in models and the observed main morphological features of the residuals. We also apply a simple unsharp masking technique in order to study the sharpest ...

2006-01-01

102

Conformal radiation therapy: technical requirements and clinical applications  

International Nuclear Information System (INIS)

Conformal radiation therapy represents a considerable and attractive challenge in oncology. Its aim is mainly to improve local control by increasing the dose with an acceptable rate of complications. This work overviews the world literature on this subject. The technical and theoretical requirements are highlighted. These requirements include a precise definition of the target volume by digital imaging (essentially CT scan), but also clear view of the target volume and the organs at risk, a specific collimation of the beam, 3-D dose calculations, optimization procedures, and a rigid immobilization of the patient with verification of his position. Moreover, the clinical applications of conformal radiation therapy are reviewed and discussed. (authors). 80 refs., 1 tab.

1995-01-01

103

Multi-Mode Lamb Wave Arrival Time Extraction for Improved Tomographic Reconstruction  

International Nuclear Information System (INIS)

An ultrasonic signal processing technique is applied to multi-mode arrival time estimation from Lamb waveforms. The basic tool is a simplified time-scale projection called a dynamic wavelet fingerprint (DWFP) which enables direct observation of the variation of features of interest in non-stationary ultrasonic signals. The DWFP technique was used to automatically detect and evaluate each candidate through-transmitted Lamb mode. The area of the dynamic wavelet fingerprint was then used as a feature to distinguish false modes caused by noise and other interference from the true modes of interest. The set of estimated arrival times were then used as inputs for tomographic reconstruction. The Lamb wave tomography images generated with these estimated arrival times were able to indicate different defects in aluminum plates.

2005-04-09

104
105

Scatter measurements for optical cone-beam computed tomography  

Energy Technology Data Exchange (ETDEWEB)

Both x-ray and optical cone-beam CT (CBCT) scanners are limited by scattered photons that contaminate the primary images. Transparent radiochromic gels and plastics are anticipated to produce less scattering than polymerization gels and hence result in reconstructed dose distributions with greater contrast and dynamic range. Four methods of scatter measurement were investigated to quantify scatter fractions using an in-house optical CBCT scanner. The methods consisted of generating either 'coin' shadows or primary beamlets in transmission images. The four methods generated similar results of 10% scatter fractions in gel transmission images for this particular scanner configuration with both leuco crystal violet and carbon black micelle gels. The scatter contributions were distributed as 5% from micelle gel, 2% from Teflon wall, 2% from refractive index matching liquid and 1% other ...

2009-05-01

106

Performance characterization of a volumetric breast ultrasound scanner  

Science.gov (United States)

The purpose of this project was to design, build, and characterize the performance of a volume breast ultrasound (VBUS) scanner that images the pendant breast. VBUS scanner design includes a: 1) clinical ultrasound scanner and transducer; 2) scanning table with a hole for the pendant breast; 3) rotational gantry; 4) probe mounting assembly; 5) compressionless breast stabilization device; 6) acquisition, control, reconstruction, and display software. Performance assessment characterized a variety of parameters including: spatial resolution, uniformity, and distortion using high and low contrast test objects in both horizontal and vertical scanning modes. The VBUS scanner modules have been constructed and initial performance evaluated. Approximately 300 scans are acquired over 360 degrees in 18 seconds. Reconstruction requires 25 ms per slice. Test object images depicted hyper- and hypo-echoic masses and ...

2007-03-01

107

A comparison of truncated total least squares with Tikhonov regularization in imaging by ultrasound inverse scattering  

International Nuclear Information System (INIS)

For good image quality using ultrasound inverse scattering, one alternately solves the well-posed forward scattering equation for an estimated total field and the ill-posed inverse scattering equation for the desired object property function. In estimating the total field, error or noise contaminates the coefficients of both matrix and data of the inverse scattering equation. Previous work on ill-posed inverse ultrasonic scattering commonly used Tikhonov regularization, which considers error only in the data. The solution so obtained is not precise enough to reconstruct the quantitative internal structure of a large or high-contrast object. This paper adopts the truncated total least squares method, simultaneously considering error and noise on both sides of the inverse scattering equation, and compares it with the classical Tikhonov regularization. We show that it can substantially improve reconstruction fit and ...

2003-08-07

108

Imaging automation and volume tomographic visualization at Texas Neutron Imaging Facility  

Energy Technology Data Exchange (ETDEWEB)

A thermal neutron imaging facility for real-time neutron radiography and computed tomography has been developed at the University of Texas reactor. The facility produced a good-quality radiographs and two-dimensional tomograms. Further developments have been recently accomplished. Further developments have been recently accomplished. A computer software has been developed to automate and expedite the data acquisition and reconstruction processes. Volume tomographic visualization using Interactive Data Language (IDL) software has been demonstrated and will be further developed. Volume tomography provides the additional flexibility of producing slices of the object using software and thus avoids redoing the measurements.

1999-07-01

109

Evaluation of cortical current density imaging methods using intracranial electrocorticograms and functional MRI  

British Library Electronic Table of Contents (United Kingdom)

Objective:EEG source imaging provides important information regarding the underlying neural activity from noninvasive electrophysiological measurements. The aim of the present study was to evaluate source reconstruction techniques by means of the intracranial electrocorticograms (ECoGs) and functional MRI.Methods:Five source imaging algorithms, including the minimum norm least square (MNLS), LORETA with Lp-norm (p equal to 1, 1.5 and 2), sLORETA, the minimum Lp-norm (p equal to 1 and 1.5; when p=2, the MNLS method is mathematically equivalent to the minimum Lp-norm) and L1-norm (the linear programming) methods, were evaluated in a group of 10 human subjects, in a paradigm with somatosensory stimulation. Cortical current density (CCD) distributions were estimated from the scalp somatosensor...

2007-01-01

110

Brain CT image and handedness of schizophrenia  

International Nuclear Information System (INIS)

Brain CT images were reviewed of 98 schizophrenic patients and 90 healthy persons in relation to handedness and aging. CT images were further reconstructed to examine morphologically subtle changes in each region. Schizophrenic patients had progressive brain atrophy and dilated lateral ventricles, especially on the left side and in the posterior part of the lateral ventricle. These findings were more marked in left-handed than in right-handed schizophrenic patients. According to age groups, there were significant differences between schizophrenic and normal persons over the age of 40. The incidence of left handedness was significantly higher in schizophrenic patients in their fourties than the age-matched normal persons (31.4% vs 15.1%). Morphological abnormality and laterality might be due to the same pathologic consequences. (N.K.).

111

Multi-domain, higher order level set scheme for 3D image segmentation on the GPU  

DEFF Research Database (Denmark)

Level set method based segmentation provides an efficient tool for topological and geometrical shape handling. Conventional level set surfaces are only $C^0$ continuous since the level set evolution involves linear interpolation to compute derivatives. Bajaj et al. present a higher order method to evaluate level set surfaces that are $C^2$ continuous, but are slow due to high computational burden. In this paper, we provide a higher order GPU based solver for fast and efficient segmentation of large volumetric images. We also extend the higher order method to multi-domain segmentation. Our streaming solver is efficient in memory usage.

2010-01-01

112

Low-dose O3+ ion-implanted active optical planar waveguides in Nd : YAG crystals: guiding properties and micro-luminescence characterization  

International Nuclear Information System (INIS)

We report, for the first time to our knowledge, on the active optical planar waveguides in Nd : YAG laser crystals fabricated by O3+ ion implantation at low doses of ?1014 ions cm-2. The reconstructed refractive index profiles based on the measured dark-mode spectroscopy show that an enhanced refractive index well is created in the near-surface region, forming a non-leaky waveguide structure. With thermal annealing treatment at 260 0C for 90 min, the propagation losses of the waveguides could be reduced to ?3 dB cm-1 at a wavelength of 632.8 nm. The micro-luminescence investigation reveals that the emission bands of Nd3+ ions are not significantly affected by the waveguide formation processing, which shows promising potentials for efficient waveguide laser operations at near-infrared wavelength bands.

2008-09-07

113

Optimizing the acquisition time profile for a planar integral measurement system with a spinning slat collimator  

International Nuclear Information System (INIS)

This article considers a hypothetical imaging device with a spinning slat collimator that measures parallel-planar-integral data from an object. This device rotates around the object 180 deg. and stops at N positions uniformly distributed over this 180 deg. . At each stop, the device spins on its own axis 180 deg. and acquires measurements at M positions uniformly distributed over this 180 deg. . For a fixed total imaging time, an optimal distribution of the scanning time among the data measurement locations is searched by a nonlinear programming method: Nelder-Mead's simplex method. The optimal dwell time is approximately proportional to the weighting factor in the backprojector of the reconstruction algorithm. By using an optimal dwell-time profile, the reconstruction signal-to-noise ratio has a gain of 23%-24% for the filtered backprojection algorithm and a gain of 10%-18% for the iterative ...

2005-09-01

114

Nuclear mass prediction as an image reconstruction problem: can observed pattern determine mass values?  

Energy Technology Data Exchange (ETDEWEB)

Theoretical prediction of nuclear masses is analyzed as a pattern recognition problem on the N-Z plane. A global pattern is observed by plotting the differences between measured masses and Liquid Drop Model (LDM) predictions. After unfolding the data by removing the smooth LDM mass contributions, the remaining microscopic effects have proved difficult to model, although they display a striking pattern. These deviations carry information related to shell closures, nuc]ear deformation and the residual nuclear interactions. In the present work the more than 2000 known nuclear masses are studied as an array in the N-Z plane viewed through a mask, behind which the approximately 7000 unknown unstable nuclei that can exist between the proton and neutron drip lines are hidden. We show here that employing a Fourier transform deconvolution method these by masses can be predicted with similar accuracy than standard methods. We believe that a more general approach needs to be implemented, however, ...

2006-07-01

115

Nuclear mass prediction as an image reconstruction problem: can observed pattern determine mass values?  

International Nuclear Information System (INIS)

Theoretical prediction of nuclear masses is analyzed as a pattern recognition problem on the N-Z plane. A global pattern is observed by plotting the differences between measured masses and Liquid Drop Model (LDM) predictions. After unfolding the data by removing the smooth LDM mass contributions, the remaining microscopic effects have proved difficult to model, although they display a striking pattern. These deviations carry information related to shell closures, nuc]ear deformation and the residual nuclear interactions. In the present work the more than 2000 known nuclear masses are studied as an array in the N-Z plane viewed through a mask, behind which the approximately 7000 unknown unstable nuclei that can exist between the proton and neutron drip lines are hidden. We show here that employing a Fourier transform deconvolution method these by masses can be predicted with similar accuracy than standard methods. We believe that a more general approach needs to be implemented, however, ...

116

Improvement of spatial resolution in the longitudinal direction for isotropic imaging in helical CT  

Energy Technology Data Exchange (ETDEWEB)

Experiments were conducted to confirm the isotropic spatial resolution of multislice CT with a 0.5 mm slice thickness. Isotropic spatial resolution means that the spatial resolution in the transaxial plane (X-Y plane) and that in the longitudinal direction (Z direction) are equivalent. To obtain point spread function (PSF) values in the X-Y-Z directions, three-dimensional voxel data were obtained by helical scanning of a bead phantom. The modulation transfer function (MTF) values were then obtained by three-dimensional Fourier transform of the PSF. Evaluation of the spatial resolution in the X-Y-Z directions by the MTF values showed that the spatial resolution in the Z direction does not depend on the reconstruction kernel used. It was also found that the spatial resolution in the Z direction, as compared with that in the X-Y plane, is superior with the standard kernel for the abdomen and is inferior with the high-definition kernel for the ears/bones. By performing ...

2007-02-07

117

A summary of neutron radiography and neutron radioscopy applications at the University of Michigan Phoenix Memorial Laboratory  

International Nuclear Information System (INIS)

Neutron radiography and neutron radioscopy are rapidly becoming the valuable tools for nondestructive testing and basic research. The Phoenix Memorial Laboratory has developed a neutron facility capable of both film neutron radiography and real time neutron radioscopy, and has used this facility to study several phenomena of interest to the researchers in many areas. Neutrons can be used for imaging the phenomena that X-ray cannot image, such as the presence, absence or movement of hydrogenous materials inside metals such as aluminum or steel. There are three basic methods for obtaining images using neutrons: high resolution film neutron radiography, real-time neutron radioscopy and transfer film neutron radiography. The neutron radiography facility at Phoenix Memorial Laboratory, the neutron radioscopic imaging systems, the neutron radiographic detectors, lubrication studies, spray ...

1992-03-01

118

Three-frame Algorithm of Car Path Reconstruction from Airborne Traffic Data  

CERN Document Server

The airborne traffic monitoring system forms a novel technology of detecting vehicle motion. An optical digital camera located on an airborne platform produces a series of images which then are processed to recognized the fixed vehicles. In this way the video data are converted into the time sequence of frames containing the vehicle coordinates. In the present work a three-frame algorithm is developed to identify the succeeding vehicle positions. It is based on finding the neighboring points in the frame sequence characterized by minimal acceleration. To verify and optimize the developed algorithm a ``Virtual Road'' simulator was created. Finally available empirical data are analyzed using the created algorithm.

2007-01-01

119

Hard X-ray phase imaging and tomography using a grating interferometer  

International Nuclear Information System (INIS)

An interferometric technique for hard X-rays is presented. It is based on two transmission gratings and a phase-stepping technique, and it provides separate radiographs of the phase and absorption profiles of bulk samples. Tomographic reconstruction yields quantitative three-dimensional maps of the X-ray refractive index and of the attenuation coefficient, with a spatial resolution down to a few microns. The method is mechanically robust, it requires little monochromaticity, and can be scaled up to large fields of view. These are important prerequisites for use with laboratory X-ray sources. Numerous applications ranging from wave front sensing to medical radiography are presently under investigation.

2007-07-01

120

A comparison of x-ray detectors for mouse CT imaging  

International Nuclear Information System (INIS)

There is significant interest in using computed tomography (CT) for in vivo imaging applications in mouse models of disease. Most commercially available mouse x-ray CT scanners utilize a charge-coupled device (CCD) detector coupled via fibre optic taper to a phosphor screen. However, there has been little research to determine if this is the optimum detector for the specific task of in vivo mouse imaging. To investigate this issue, we have evaluated four detectors, including an amorphous selenium (a-Se) detector, an amorphous silicon (a-Si) detector with a gadolinium oxysulphide (GOS) screen, a CCD with a 3:1 fibre taper and a GOS screen, and a CCD with a 2:1 fibre taper and both GOS and thallium-doped caesium iodide (CsI:Tl) screens. The detectors were evaluated by measuring the modulation transfer function (MTF), noise power spectrum (NPS), detective quantum efficiency (DQE), stability over multiple exposures, and noise in ...

2004-12-07

121

Correct diagnosis of vascular encasement and longitudinal extension of hilar cholangiocarcinoma by four-channel multidetector-row computed tomography  

International Nuclear Information System (INIS)

Accurate diagnosis of local invasion of hilar cholangiocarcinomas is challenging due to their small size and the anatomic complexity of the hepatic hilar region. On the other hand, the correct diagnosis of local invasion is essential for assuring the possibility of curative surgery. The purpose of this study was to evaluate the feasibility of four-channel multidetector-row computed tomography (MDCT) in the assessment of vascular and bile duct involvement, by which we could obtain useful information for the surgical management of hilar cholangiocarcinoma. The subjects were 18 patients for whom the extent of tumor invasion was surgically and pathologically confirmed. All patients underwent preoperative multiphasic CT scanning by MDCT. Arterial and portal dominant phases were acquired using a detector configuration of 1.25 mm x 4 mm, and both axial and multiplanar reconstructed images were interpreted. Longitudinal extension was evaluated up to ...

2009-01-01

122

CHAPLET-3D results for the 3-D extension C5G7 Mox benchmarks  

Energy Technology Data Exchange (ETDEWEB)

The 3-dimensional (3D) extension C5G7 MOX benchmark problems were solved by CHAPLET-3D code which is based on the idea of dynamic linkage of the multi-plane method of characteristics solutions. The benchmark results are quite accurate in comparison with the reference solutions, independently of the axial solver incorporated in the CHAPLET-3D code. (author)

2005-07-01

123

Designing engineering upgradability into magnetic resonance imagers: Impact on future costs  

Energy Technology Data Exchange (ETDEWEB)

MRI is a powerful diagnostic modality of expanding availability. Equipment and installation amount to nearly $2M per site. An important component of diagnostic efficacy is not just equipment costs but also replacement costs, which for x-ray CT amount to 14-20% of the purchase cost per year; and in the early years of that technology reached 30-50%. The authors show how design choices made during the RandD stages of MRI development have allowed them to improve system performance parameters such as data reconstruction, archiving and display speeds, computational capabilities, operator interfaces, imaging sequence flexibility and signal-to-noise levels. Over the last four years these improvements have been made at a retrofit cost well below the target of 6-7% of the purchase price per year.

1987-02-01

124

Clinical Experiences With Onboard Imager KV Images for Linear Accelerator-Based Stereotactic Radiosurgery and Radiotherapy Setup  

International Nuclear Information System (INIS)

Purpose: To report our clinical experiences with on-board imager (OBI) kV image verification for cranial stereotactic radiosurgery (SRS) and radiotherapy (SRT) treatments. Methods and Materials: Between January 2007 and May 2008, 42 patients (57 lesions) were treated with SRS with head frame immobilization and 13 patients (14 lesions) were treated with SRT with face mask immobilization at our institution. No margin was added to the gross tumor for SRS patients, and a 3-mm three-dimensional margin was added to the gross tumor to create the planning target volume for SRT patients. After localizing the patient with stereotactic target positioner (TaPo), orthogonal kV images using OBI were taken and fused to planning digital reconstructed radiographs. Suggested couch shifts in vertical, longitudinal, and lateral directions were recorded. kV images were also taken immediately after ...

2009-02-01

127

High-Resolution Computed Tomography with Single-Slice Computed Tomography and 16-Channel Multidetector Computed Tomography: A Comparison Regarding Visibility and Motion Artifacts  

International Nuclear Information System (INIS)

Background: High-resolution computed tomography is the image procedure of choice in the evaluation of interstitial lung disease. Multidetector-row computed tomography provides the possibility of simultaneous reconstruction of thin and thick slices from the same raw data, acquired from one single series. Thus, it may be tempting to exclude the step-and-shoot series. Purpose: To compare high-resolution computed tomography (HRCT step-and-shoot) from single-slice CT (SSCT) and 16-channel multidetector CT (MDCT) in terms of visibility and motion artifacts, and to investigate whether thin images reconstructed from helical MDCT are equal to or better than conventional HRCT by SSCT in terms of visibility and motion artifacts. Material and Methods: 20 patients underwent HRCT step-and-shoot by SSCT (SSCT step-and-shoot) and MDCT (MDCT step-and-shoot), and a helical MDCT acquisition (MDCT helical). ...

2007-11-01

128

Electrophysiological Study and Catheter Ablation with 3D Mapping  

Medline Plus

... see and electrophysiological study and catheter ablation with 3D mapping. During the procedure, doctors look at the ... perform a electrophysiology study with ablation, using our 3D mapping system. Keep in mind, that during the ...

129

Comparison of stereotactic radiosurgery and fractionated stereotactic radiotherapy of acoustic neurinomas according to 3-D tumor volume shrinkage and quality of life  

International Nuclear Information System (INIS)

Background and purpose: stereotactic radiosurgery (SRS) and also fractionated stereotactic radiotherapy (SRT) offer high local control (LC) rates (> 90%). This study aimed to evaluate three-dimensional (3-D) tumor volume (TV) shrinkage and to assess quality of life (QoL) after SRS/SRT. Patients and methods: from 1999 to 2005, 35/74 patients were treated with SRS, and 39/74 with SRT. Median age was 60 years. Treatment was delivered by a linear accelerator. Median single dose was 13 Gy (SRS) or 54 Gy (SRT). Patients were followed up ? 12 months after SRS/SRT. LC and toxicity were evaluated by clinical examinations and magnetic resonance imaging. 3-D TV shrinkage was evaluated with the planning system. QoL was assessed using the questionnaire Short Form-36. Results: Median follow-up was 50/36 months (SRS/SRT). Actuarial 5-year freedom from progression/overall survival was 88.1%/100% ...

2009-09-01

130

Trabecular scaffolds created using micro CT guided fused deposition modeling  

British Library Electronic Table of Contents (United Kingdom)

Free form fabrication and high resolution imaging techniques enable the creation of biomimetic tissue engineering scaffolds. A 3D CAD model of canine trabecular bone was produced via micro CT and exported to a fused deposition modeler, to produce polybutylene terephthalate (PBT) trabeculated scaffolds and four other scaffold groups of varying pore structures. The five scaffold groups were divided into subgroups (n=6) and compression tested at two load rates (49?N/s and 294?N/s). Two groups were soaked in a 25??C saline solution for 7?days before compression testing. Micro CT was used to compare porosity, connectivity density, and trabecular separation of each scaffold type to a canine trabecular bone sample. At 49?N/s the dry trabecular scaffolds had a compressive stiffness of 4.94?1.19?MP...

2008-01-01

131

Road Interpretation for Driver Assistance Based on an Early Cognitive Vision System  

DEFF Research Database (Denmark)

In this work, we address the problem of road interpretation for driver assistance based on an early cognitive vision system. The structure of a road and the relevant traf?c are interpreted in terms of ego-motion estimation of the car, independently moving objects on the road, lane markers and large scale maps of the road. We make use of temporal and spatial disambiguation mechanisms to increase the reliability of visually extracted 2D and 3D information. This information is then used to interpret the layout of the road by using lane markers that are detected via Bayesian reasoning. We also estimate the ego-motion of the car which is used to create large scale maps of the road and also to detect independently moving objects. Sample results for the presented algorithms are shown on a stereo image sequence, that has been collected from a structured road.

2009-01-01

132

Airbags to Martian Landers: Analyses at Sandia National Laboratories  

Energy Technology Data Exchange (ETDEWEB)

A new direction for the national laboratories is to assist US business with research and development, primarily through cooperative research and development agreements (CRADAs). Technology transfer to the private sector has been very successful as over 200 CRADAs are in place at Sandia. Because of these cooperative efforts, technology has evolved into some new areas not commonly associated with the former mission of the national laboratories. An example of this is the analysis of fabric structures. Explicit analyses and expertise in constructing parachutes led to the development of a next generation automobile airbag; which led to the construction, testing, and analysis of the Jet Propulsion Laboratory Mars Environmental Survey Lander; and finally led to the development of CAD based custom garment designs using 3D scanned images of the human body. The structural analysis of these fabric structures is described as well as a ...

1994-03-01

133

Adaptive Radiation Therapy for Localized Mesothelioma with Mediastinal Metastasis Using Helical Tomotherapy  

British Library Electronic Table of Contents (United Kingdom)

The purpose of this study was to compare 2 adaptive radiotherapy strategies with helical tomotherapy. A patient having mesothelioma with mediastinal nodes was treated using helical tomotherapy with pretreatment megavoltage CT (MVCT) imaging. Gross tumor volumes (GTVs) were outlined on every MVCT study. Two alternatives for adapting the treatment were investigated: (1) keeping the prescribed dose to the targets while reducing the dose to the OARs and (2) escalating the target dose while maintaining the original level of healthy tissue sparing. Intensity modulated radiotherapy (step-and-shoot IMRT) and 3D conformal radiotherapy (3DCRT) plans for the patient were generated and compared. The primary lesion and nodal mass regressed by 16.2% and 32.5%, respectively. Adapted GTVs and reduced plan...

2009-01-01

134

GPS and Google Earth based 3D assisted driving system for trucks in surface mines  

British Library Electronic Table of Contents (United Kingdom)

In order to reduce the number of surface mining accidents related to low visibility conditions and blind spots of trucks and to provide 3D information for truck drivers and real time monitored truck information for the remote dispatcher, a 3D assisted driving system (3D-ADS) based on the GPS, mesh-wireless networks and the Google-Earth engine as the graphic interface and mine-mapping server, was developed at Virginia Tech. The research results indicate that this 3D-ADS system has the potential to increase reliability and reduce uncertainty in open pit mining operations by customizing the local 3D digital mining map, constructing 3D truck models, tracking vehicles in real time using a 3D interface ...

2010-01-01

135

Anatomical changes after radical surgery and reconstruction with pedunculated or revascularized flaps in advanced head and neck cancer: CT and MR features; Modificazioni anatomiche dopo chirurgia radicale e ricostruzione con lembi peduncolati o rivascolarizzati nei tumori cervico-facciali negli stadi avanzati: Aspetti con Tomografia Computerizzata e Risonanza Magnetica  

Energy Technology Data Exchange (ETDEWEB)

January, 1992, to October, 1995, sixty-four patients with advanced head and neck cancer underwent head and neck reconstructive surgery using myocutaneous or revascularized flaps; in the same period, all patients were consecutively examined with CT and MRI. Myocutaneous flaps were used in 26 patients: 12 flaps were tubular and 14 linear. Revascularized flaps were used in 38 patients: to repair a large defect in 26 patients (14 latissimus dorsi flaps and 12 temporal muscle flaps) and to repair an oral damage in 12 patients (5 revascularized radial and 7 jejunal flaps). CT and MR images of myocutaneous flaps showed the flaps as fatty areas, repairing large surgical defects, hypodense at CT and hyperintense at MRI, with no post-contrast enhancement. The appearance of revascularized flaps at CT and MRI depends on the characteristics of the structure used to repair the surgical defect: jejunal and radial flaps appeared as mostly fatty thickened ...

1997-04-01

136

Anatomical changes after radical surgery and reconstruction with pedunculated or revascularized flaps in advanced head and neck cancer: CT and MR features  

International Nuclear Information System (INIS)

January, 1992, to October, 1995, sixty-four patients with advanced head and neck cancer underwent head and neck reconstructive surgery using myocutaneous or revascularized flaps; in the same period, all patients were consecutively examined with CT and MRI. Myocutaneous flaps were used in 26 patients: 12 flaps were tubular and 14 linear. Revascularized flaps were used in 38 patients: to repair a large defect in 26 patients (14 latissimus dorsi flaps and 12 temporal muscle flaps) and to repair an oral damage in 12 patients (5 revascularized radial and 7 jejunal flaps). CT and MR images of myocutaneous flaps showed the flaps as fatty areas, repairing large surgical defects, hypodense at CT and hyperintense at MRI, with no post-contrast enhancement. The appearance of revascularized flaps at CT and MRI depends on the characteristics of the structure used to repair the surgical defect: jejunal and radial flaps appeared as mostly fatty thickened ...

1997-01-01

137

Evaluation of craniosynostosis surgery. Technetium-99m-HMPAO SPECT cerebral blood flow study in children with craniosynostosis  

International Nuclear Information System (INIS)

Premature fusion of multiple cranial sutures has been associated with increased intracranial pressure and the potential for mental impairment. Isolated craniosynostosis, however, is considered a benign condition primarily reconstructed for aesthetic purposes. A comparative analysis, to assess the differences between pre- and post operatory cerebral perfusion of patients who underwent surgery for simple cranisynostosis, was performed using single positron emission computed tomography ''SPECT'' Images. Cerebral blood flow studies were performed using "9"9"mTc-HMPAO SPECT in children with simple cranisynotoses. The subjects were 8 children with craniosynostosis (age, 2 months-9 years). Preoperative revealed regional hypovascularity in the cerebral hemisphere in 5 cases (62%). In 6 patients the cerebral blood flow normalized or increased after craniofacial reconstruction. We demonstrated the presence of regional hypovascularity ...

1998-09-01

138

Quantification of cardiac function with multislice spiral CT using retrospective EKG-gating: comparison with MRI  

International Nuclear Information System (INIS)

Purpose: To quantify left ventricular function derived from retrospectively ECG-gated multislice spiral CT (MSCT) data sets in comparison to MRI. Materials and Methods: In 16 patients (14 males, 2 females, mean age 56.8 #+-# 11.5 years), retrospectively ECG-gated MSCT angiography of the coronary arteries and breath-hold steady state free precession cine MRI were performed. From MSCT data-sets, 20 axial image series were reconstructed every 5% of the RR interval. Multiplanar images were reformatted in the short axis orientation from axial images. End-systolic and end-diastolic images were selected. From these images end-systolic volume (ESV), end-diastolic volume (EDV) and stroke volume (SV) as well as the ejection fraction (EF) and myocardial mass (MM) were determined using the Simpson's method and compared with MRI. Furthermore, image ...

2003-01-01

139

Sequential stratigraphy and probabilistic modeling of reservoirs from a deep sea fan (Namorado field, Brazil). Integration of geological and geophysical data; Stratigraphie sequentielle et modelisation probabiliste des reservoirs d`un cone sous-marin profond (champ de Namorado, Bresil). Integration des donnees geologiques et geophysiques  

Energy Technology Data Exchange (ETDEWEB)

The main objective of this dissertation is to build a numerical 3D geological model of a turbidite reservoir using well and seismic data. For the, the first step was to elaborate a depositional model using a high-resolution genetic stratigraphy approach. Simultaneously, the stratigraphic inversion over the seismic data resulted in an optimal acoustic impedance model. Both models, were used to build, by geostatistical methods, a 3-D geological model, which represents the spatial distribution of the reservoir facies. The studied case is the late Cretaceous Namorado turbidite system in the Campos basin, which is the reservoir of the Namorado oil field, located 80 km from the Brazilian coast, under a bathymetry between 110 and 250 m. The reservoir is a turbidite succession with 90 to 180 m thickness. It is composed by sand-supported conglomerates, matrix-supported conglomerate, massive sandstones, shales, ...

1997-01-29

140

3D Fourier synthesis of a new X-ray picture identical in projection to a previous picture  

Energy Technology Data Exchange (ETDEWEB)

A central problem in diagnostic radiology is to compare a new X-ray picture with a previous picture and from this comparison be able to decide if anatomical changes have occurred in the patient or not. It is of primary interest that these pictures are identical in projection. If not it is difficult to decide with confidence if differences between the pictures are due to anatomical changes or differences in their projection geometry. In this thesis we present a non invasive method that makes it possible to find the relative changes in the projection geometry between the exposure of a previous picture and a new picture. The method presented is based on the projection slice theorem (central section theorem). Instead of an elaborate search for a single new picture a pre-planned set of pictures are exposed from a circular orbit above the patient. By using 3D Fourier transform techniques we are able to synthesize a new X-ray picture from this set of ...

1993-11-01

141

Photochromes for Optical Memory  

International Science & Technology Center (ISTC)

Photochromes for New Generation of Highly Efficient Computers with Three Dimensional (3D) Optical Memory

146

 

Medline Plus

... 2009) Arrhythmia Electrophysiological Study and Catheter Ablation with 3D Mapping (Mercy Hospital, Miami, FL, 11/15/2007) ...

147

Numerical Models of Sgr A*  

CERN Document Server

We review results from general relativistic axisymmetric magnetohydrodynamic simulations of accretion in Sgr A*. We use general relativistic radiative transfer methods and to produce a broad band (from millimeter to gamma-rays) spectrum. Using a ray tracing scheme we also model images of Sgr A* and compare the size of image to the VLBI observations at 230 GHz. We perform a parameter survey and study radiative properties of the flow models for various black hole spins, ion to electron temperature ratios, and inclinations. We scale our models to reconstruct the flux and the spectral slope around 230 GHz. The combination of Monte Carlo spectral energy distribution calculations and 230 GHz image modeling constrains the parameter space of the numerical models. Our models suggest rather high black hole spin ($a_*\\approx 0.9$), electron temperatures close to the ion temperature ($T_i/T_e \\sim 3$) and high ...

2010-01-01

148

Ultrashort echo time MRI of cortical bone at 7 tesla field strength: A feasibility study  

British Library Electronic Table of Contents (United Kingdom)

AbstractPurpose: To implement and examine the feasibility of a three-dimensional (3D) ultrashort TE (UTE) sequence on a 7 Tesla (T) clinical MR scanner in comparison with 3T MRI at high isotropic resolution. Materials and Methods: Using an in-house built saddle coil at both field strengths we have imaged mid-diaphysial sections of five fresh cadaveric specimens of the distal tibia. An additional in vivo scan was performed at 7 Tesla using a quadrature knee coil. Results: Using the same type of saddle coil at both field strengths, a significant increase in SNR at 7T compared with 3T (factor 1.7) was found. Significantly shorter T2* values were found at the higher field strength (T2* = 552.2 126 s at 7T versus T2* = 1163 391 s at 3T). Conclusion: UHF MRI at 7T has great potential for imaging...

2011-01-01

149

Applications with a new low-temperature UHV STM at 5 K  

International Nuclear Information System (INIS)

A new dedicated UHV STM for investigations at T#<=#5 K is presented. To achieve such low temperatures and to ensure a high thermal stability, the low-temperature (LT) STM described here has a concentric system of bath cryostats. There are openings for tip and sample exchange at low T, and windows with an infrared radiation shield for optical access, which can both be closed by a door mechanism for LT-STM measurements. Efficient vibration isolation is realized by using spring suspension with eddy current damping. With the 3-d coarse positioning unit any region of interest within 5 mm by 5 mm on the sample is accessible even at 5 K. For short turn-around cycles the sample and tip can both be exchanged at low temperatures. Atomically resolved images of Au(111) at 5 K in UHV demonstrate the excellent performance of this LT STM. As a typical application example the appearance of a charge-density wave on NbSe_2, which occurs ...

1998-03-01

150

Helical CT defecography  

International Nuclear Information System (INIS)

The purpose of this work is to investigate the possible role of Helical CT defecography in pelvic floor disorders by comparing the results of the investigations with those of conventional defecography. The series analyzed consisted of 90 patients, namely 62 women and 28 men, ranging in age 24-82 years. They were all submitted to conventional defecography, and 18 questionable cases were also studied with Helical CT defecography. The conventional examination was performed during the 4 standard phases of resting, squeezing, Valsalva and straining; it is used a remote-control unit. The parameters for Helical CT defecography were: 5 mm beam collimation, pitch 2, 120 KV, 250 m As and 18-20 degrees gantry inclination to acquire coronal images of the pelvic floor. The rectal ampulla was distended with a bolus of 300 mL nonionic iodinated contrast agent (dilution: 3g/cc). The patient wore a napkin and was seated on the table, except for those who could not hold the position ...

1999-11-01

151

Clinically silent heterotaxy with polysplenia syndrome and IVC azygous continuation draining to SVC: CT findings. Case report  

International Nuclear Information System (INIS)

Patients with heterotaxy syndrome often have complex cardiac and extracardiac anomalies requiring further detailed diagnostic evaluation. They often present severe cardiac failure early in life. Newer radiological modalities in the form of spiral computed tomography (CT) and three-dimensional reconstruction of spiral CT allow clear definition of the anatomy of these anomalies. A 59-year-old woman was diagnosed with polysplenia and multiple anomalies in an abdominal ultrasonography (US) during a control medical examination due to a trivial dietary mistake. She was then referred to our institution for further examination of these anomalies and an additional thoraco-abdominal computed tomography (CT) examination. The patient was totally asymptomatic at the time of admission. There was no significant past history and no abnormal laboratory data. We performed abdominal, pelvic and thoracic CT examinations using Somatom Siemens Emotion scanner. Non-enhanced sections were ...

2007-01-01

152

Morphological characteristics and medium-term evolution of the beaches between Ceuta and Cabo Negro (Morocco)  

British Library Electronic Table of Contents (United Kingdom)

This work presents the results of a combined study on the beach morphology and the evolution at short- and medium-term of the littoral between Ceuta and Cabo Negro (Morocco). It is an interesting sector showing a great increase of human occupation and coastal structures. The monitoring program allowed for the reconstruction of the beach morphological behavior and the seasonal changes. The studied beaches presented reflective profiles recording little seasonality, with the most notable morphological changes being strictly related to storms. Surf Similarity and Surf Scaling parameters highlighted the existence of intermediate and reflective beach states, characterized by plunging breakers. Aerial photographs and a satellite image have been geo-referenced and elaborated with GIS tools to reco...

2007-01-01

153

Lacrimal gland masses on CT and MRI: a report of four cases  

International Nuclear Information System (INIS)

In an extended case report, we discuss four cases with masses in the lacrimal fossa representing the most important entities in this region (lymphoma, pleomorphadenoma, inflammatory pseudotumor, and malignant epithelial tumor). The different indications for CT and MRI are explained. For the differential diagnosis of lacrimal gland lesions, the following imaging parameters are important: The shape of the lacrimal gland, the inner structure, the degree of contrast enhancement, and the surrounding bony structures. In the evaluation of the expansion of lacrimal gland lesions, CT in thin slices with multiplanar reconstructions is equal to MRI. However, the contrast-enhancement of lacrimal glands is better evaluated with MRI than with CT. The bony structures are better visualized on CT than on MRI. (orig.).

154

Heparin binding sites on Ross River virus revealed by electron cryo-microscopy  

International Nuclear Information System (INIS)

Cell surface glycosaminoglycans play important roles in cell adhesion and viral entry. Laboratory strains of two alphaviruses, Sindbis and Semliki Forest virus, have been shown to utilize heparan sulfate as an attachment receptor, whereas Ross River virus (RRV) does not significantly interact with it. However, a single amino acid substitution at residue 218 in the RRV E2 glycoprotein adapts the virus to heparan sulfate binding and expands the host range of the virus into chicken embryo fibroblasts. Structures of the RRV mutant, E2 N218R, and its complex with heparin were determined through the use of electron cryo-microscopy and image reconstruction methods. Heparin was found to bind at the distal end of the RRV spikes, in a region of the E2 glycoprotein that has been previously implicated in cell-receptor recognition and antibody binding.

2005-02-20

155

Nanofocusing refractive X-ray lenses  

Energy Technology Data Exchange (ETDEWEB)

This thesis is concerned with the optimization and development of the production of nanofocusing refractive X-ray lenses. These optics made of either silicon or diamond are well-suited for high resolution X-ray microscopy. The goal of this work is the design of a reproducible manufacturing process which allows the production of silicon lenses with high precision, high quality and high piece number. Furthermore a process for the production of diamond lenses is to be developed and established. In this work, the theoretical basics of X-rays and their interaction with matter are described. Especially, aspects of synchrotron radiation are emphasized. Important in X-ray microscopy are the different optics. The details, advantages and disadvantages, in particular those of refractive lenses are given. To achieve small X-ray beams well beyond the 100 nm range a small focal length is required. This is achieved in refractive lenses by moving to a compact lens design where several single lenses ...

2010-02-05

156

Multidetector-row helical CT: analysis of time management and workflow  

International Nuclear Information System (INIS)

The purpose of this study was to evaluate time management and workflow for multidetector-row helical CT (MDCT). Time for patient and data handling of at total of 580 patients were evaluated at two different time periods (December 1999, August 2000), each for the following baseline measurements: (a) change of clothes/instruction; (b) patient placement on the CT table/i.v. catheter; (c) CT planning and programming; (d) CT data acquisition; (e) CT data reconstruction; (f) CT data storage/printing. All imaging was performed on a Somatom Volume Zoom (Siemens, Erlangen, Germany). Time measurements summarized for different CT protocols revealed the following: (a) 5:01 min (#+-#2.06 min); (b) 4:36 min (#+-#2.43 min); (c) 4:11 min (#+-#2.55 min); (d) 0:43 min (#+-#0.15 min); (e) 6:59 min (#+-#2.39 min); (f) 09:51 min (#+-#3.51 min). Planning and programming was most time-consuming for CT angiography, whereas chest and abdominal CT needed only 3:26 and ...

2002-03-01

157

64-slice multidetector coronary CT angiography: in vitro evaluation of 68 different stents  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to test a large sample of different coronary artery stents using four image reconstruction approaches with respect to lumen visualization, lumen attenuation, and image noise in 64-slice multidetector-row computed tomography (MDCT) in vitro and to provide a catalogue of currently used coronary artery stents when imaged with state-of the-art MDCT. We examined 68 different coronary artery stents (57 stainless steel, four cobalt-chromium, one cobalt-alloy, two nitinol, four tantalum) in a coronary artery phantom (vessel diameter 3 mm, intravascular attenuation 250 HU, extravascular density -70). Stents were imaged in axial orientation with standard parameters: 32x0.6 collimation, pitch 0.24, 680 mAs, 120 kV, rotation time 0.37 s. Four different image reconstructions were obtained with varying convolution kernels and ...

2006-04-15

158

Comparison of Ceramic, Metal and Polymer Crevice Formers on the Crevice Corrosopn Behavior of Ni-CR-Mo Alloy C22  

Energy Technology Data Exchange (ETDEWEB)

A necessary condition for crevice corrosion is that a crevice former create a sufficiently tight, restricted geometry on the metal surface to support the development of critical crevice chemistry. Crevice corrosion is affected by the crevice geometry (tightness) and the properties of the crevice former. The objective of this study is to determine the effect of the crevice former material on the evolution of localized corrosion-damage. A standard crevice corrosion test method is modified by (a) the use of ceramic, metal or polymer materials as the crevice former and (b) the variation of size and shape of the crevice. This study focuses on the post initiation stage of crevice corrosion and addresses factors that may limit the initiation of localized corrosion and also slow or stop the continued propagation of corrosion. Controlled crevice corrosion tests are performed under aggressive, accelerated conditions on Ni-Cr-Mo alloy C-22 and other alloys for comparison. Multiple techniques are ...

2006-05-08

159

A New Approach to Studying Biological and Soft Materials Using Focused Ion Beam Scanning Electron Microscopy (FIB SEM)  

International Nuclear Information System (INIS)

Over the last decade techniques such as confocal light microscopy, in combination with fluorescent labelling, have helped biologists and life scientists to study biological architectures at tissue and cell level in great detail. Meanwhile, obtaining information at very small length scales is possible with the combination of sample preparation techniques and transmission electron microscopy (TEM) or scanning transmission electron microscopy (STEM). Scanning electron microscopy (SEM) is well known for the determination of surface characteristics and morphology. However, the desire to understand the three dimensional relationships of meso-scale hierarchies has led to the development of advanced microscopy techniques, to give a further complementary approach. A focused ion beam (FIB) can be used as a nano-scalpel and hence allows us to reveal internal microstructure in a site-specific manner. Whilst FIB instruments have been used to study and verify the three-dimensional architecture of ...

2006-02-22

160

Reconstruction of the trachea  

UK PubMed Central (United Kingdom)

Grillo, H. C. (1973).Thorax, 28, 667-679. Reconstruction of the trachea. Experience in 100 consecutive cases. Anatomic mobilization of the trachea...Full Text Available

1973-11-01

161

Impact on sexual function after reconstructive surgery for anterior urethral stricture disease  

UK PubMed Central (United Kingdom)

Objective:To evaluate the effect of urethral reconstructive surgery on sexual drive, erectile function and ejaculation.Materials and Methods:The...Full Text Available

2010-04-01

162

Reservoir characterization of the Mississippian Ratcliffe, Richland County, Montana, Williston Basin. Topical report, September 1997  

Energy Technology Data Exchange (ETDEWEB)

This topical report is a compilation of characterizations by different disciplines of the Mississippian Ratcliffe in portions of Richland County, MT. Goals of the report are to increase understanding of the reservoir rocks, oil-in-place, heterogeneity and methods for improved recovery. The report covers investigations of geology, petrography, reservoir engineering and seismic. The Ratcliffe is a low permeability oil reservoir which appears to be developed across much of the study area and occurs across much of the Williston Basin. The reservoir has not been a primary drilling target in the study area because average reserves have been insufficient to payout the cost of drilling and completion despite the application of hydraulic fracture stimulation. Oil trapping does not appear to be structurally controlled. For the Ratcliffe to be a viable drilling objective, methods need to be developed for (1) targeting better reservoir development and (2) better completions. A geological model is ...

1998-07-01

163

Durability of cement-based materials: modeling of the influence of physical and chemical equilibria on the microstructure and the residual mechanical properties; Durabilite des materiaux cimentaires: modelisation de l'influence des equilibres physico-chimiques sur la microstructure et les proprietes mecaniques residuelles  

Energy Technology Data Exchange (ETDEWEB)

A large part of mechanical and durability characteristics of cement-based materials comes from the performances of the hydrated cement, cohesive matrix surrounding the granular skeleton. Experimental studies, in situ or in laboratory, associated to models, have notably enhanced knowledge on the cement material and led to adapted formulations to specific applications or particularly aggressive environments. Nevertheless, these models, developed for precise cases, do not permit to specifically conclude for other experimental conclusions. To extend its applicability domain, we propose a new evolutive approach, based on reactive transport expressed at the microstructure scale of the cement. In a general point of view, the evolution of the solid compounds of the cement matrix, by dissolutions or precipitations, during chemical aggressions can be related to the pore solution evolution, and this one relied to the ionic exchanges with the external environment. By the utilization of a ...

2004-09-15

164

Skeletal remodeling dynamics: New approaches with imaging instrumentation  

Energy Technology Data Exchange (ETDEWEB)

This report of progress and future objectives timetable is based on an included schematic of goals and objectives and the project abstract which is included as Appendix 1. Five matters are summarized in the order of (1) novel methods of calcified bone confocal microscopy and reconstruction image analysis of decalcified beagle and human cortical bone serial sections, (2) macroscopic cross-correlation of beagle and human cortical and cancellous bone fractions with CT analysis, (3) guidance to the most radiobiologically important skeletal regions of interest with the just completed {sup 90}Sr bone tumor map from life time beagle studies, (4) deposition patterns of radioactive agents that participate in apatite crystal nucleation processes in bone and leave radiation-excited electrons trapped in bone mineral, and (5) the budget period timetable. The discovery that beta particles from {sup 166}Ho (T{sub {1/2}} =26 hr, {beta}{sub max} = 1.8 MeV) ...

1991-12-01

165

Review of progress in quantitative NDE. Abstracts  

Energy Technology Data Exchange (ETDEWEB)

The meeting was arranged into the following sessions: introductory; advanced ceramics and ceramic composites; ceramic and metal matrix composites; electronic materials and devices; acoustoelasticity, stress, and texture; composites-porosity, strength, and UT propagation; process modeling and monitoring; thermal wave physics; material properties, composites, surfaces, and interfaces; acoustic emission; ferromagnetic materials; new sensors; NDE reliability assessment; elastic wave scattering and propagation; image analysis, data storage, and signal processing; UT transducers; weldments and bonded materials; eddy current models; unified life cycle engineering; x rays, CT, and NMR; eddy current probes and instruments; acoustic microscopy imaging, and reconstruction; signal processing, measurement techniques, and systems; NDE applications of artificial intelligence; crack behavior influenced by history; inversion procedures for ...

1986-01-01

166

The safety issues of medical robotics  

International Nuclear Information System (INIS)

In this paper, we put forward a systematic method to analyze, control and evaluate the safety issues of medical robotics. We created a safety model that consists of three axes to analyze safety factors. Software and hardware are the two material axes. The third axis is the policy that controls all phases of design, production, testing and application of the robot system. The policy was defined as hazard identification and safety insurance control (HISIC) that includes seven principles: definitions and requirements, hazard identification, safety insurance control, safety critical limits, monitoring and control, verification and validation, system log and documentation. HISIC was implemented in the development of a robot for urological applications that was known as URObot. The URObot is a universal robot with different modules adaptable for 3D ultrasound image-guided interstitial laser coagulation, radiation seed ...

2001-08-01

167

Real-time 3-D SAFT-UT system evaluation and validation  

International Nuclear Information System (INIS)

SAFT-UT technology is shown to provide significant enhancements to the inspection of materials used in US nuclear power plants. This report provides guidelines for the implementation of SAFT-UT technology and shows the results from its application. An overview of the development of SAFT-UT is provided so that the reader may become familiar with the technology. Then the basic fundamentals are presented with an extensive list of references. A comprehensive operating procedure, which is used in conjunction with the SAFT-UT field system developed by Pacific Northwest Laboratory (PNL), provides the recipe for both SAFT data acquisition and analysis. The specification for the hardware implementation is provided for the SAFT-UT system along with a description of the subsequent developments and improvements. One development of technical interest is the SAFT real time processor. Performance of the real-time processor is impressive and comparison is made of this dedicated parallel processor to a ...

1993-05-17

168

4D experience on Girassol Field block 17, Angola  

Energy Technology Data Exchange (ETDEWEB)

The Girassol field is located in Angolan deep water of Block 17 and consists of large vertically stacked turbidities complexes. The reservoir extends over approximately 200 km{sup 2} and water depth ranges between 1300 and 1400 meters. In that context High Resolution 3D seismic became the most valuable tool to describe and monitor the reservoir. The field development plan took into account, through re-injection of the gas into the reservoir, Total environmental policy imposing the recycling of production gas. Monitoring of this injection was the main reason to shoot the first High Resolution 4D extremely early in the life of field. Despite the complexity of interpretation due to complex fluid situation and pressure effect, the results went way beyond expectations as the 4D images are of very high quality. Data has also been used to update and refine the reservoir flow model as well as to help deciding on the location of ...

2004-07-01

169

Characterisation of thin films on rough steel substrates by FTIR microscopy and imaging  

International Nuclear Information System (INIS)

Complete text of publication follows. According to the new European regulations (Restrictions of Hazardous Substance Directive), there is an emerging demand for environmental friendly metal treatments instead on formerly used chromate conversion coating technique. The aim of the present investigations was to characterise and compare silicon containing protective thin layers on roughened galvanized steel surfaces (with average roughness of 0.7 microns), using FTIR microscopy and imaging techniques. The silicon containing coatings were produced either by Chemical Vapour Deposition (CVD) or by wet chemical treatment using liquid silane. FTIR techniques offer new possibilities in the characterisations and chemical mapping of differently coated thin films, besides SEM+EDS, AFM, nanoindentation, XPS measurements (P. Nemeth et al., Materials Science Forum, 589 (2008) 433-438). All measurements were carried out by a Varian FTS-7000 spectrometer with a 'Stingray' microscope ...

170

TECAB - Totally Endoscopic Coronary Artery Bypass  

Medline Plus

... CT angiograph for the peripheral rteries. a beautiful 3D-vision on the structures inside e chest. Okay. ... have an angled camera here. This is a 3D camera, and the surgeon has got th What ...

171

Stent placement under real-time MR control: first experience in an animal model; Stentplazierung unter Echtzeit-MR-Kontrolle: erste tierexperimentalle Erfahrungen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: The aim of this study was to test the feasibility of iliac artery stent placement under MR guidance with real-time MR radial scanning in an animal model. Materials and methods: The experiments were performed on three pigs in a 1.5 T scanner. Radial scanning with a gradient echo technique (T{sub R} 8.4 ms, T{sub E} 3.6 ms, flip angle 10 ) was used. A dedicated backprojector performed the reconstruction of the raw data in real-time. The resulting MR-images were displayed on LCD screens beside the magnet. The sliding window reconstruction technique allowed image acquistion at a frame rate of 16 images per second. MR-compatible self-expanding stents with a diameter of 8 mm and a length of 3 cm were placed into the left iliac artery. Their positions were verified by digital subtraction angiography (DSA) and compared to MRI. Results: All stents were successfully placed. Stent ...

1998-12-01

172

Investigation of respiratory-dependent movements of pulmonary space-occupying lesions with MRI; Untersuchung der atemabhaengigen Bewegungen pulmonaler Raumforderungen mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

Parallel imaging and echo sharing techniques have markedly reduced the acquisition times for MRI of large volumes. Dynamic 2 and 3-dimensional data sets of the chest with high temporal resolution (up to 10 images/s with single slice and 2 volume/s) allow an analysis of respiratory motion of the lungs and tumors. Time-resolved 2D series in preselected planes can be used to observe respiratory motion during free breathing or after respiratory commands, e.g. to exclude chest wall invasion by a tumor or for diagnosing impairment of respiratory mechanics. Time-resolved 3D-series (4D-MRI) allow monitoring of the spatial displacement of the lungs and tumors as a whole volume. Present limitations such as an overestimation of tumor size and an underestimation of displacement due to a limited temporal resolution are expected to be overcome with further technical developments. However, 4D-MRI already appears to be ...

2009-08-15

173

Monovision  

Medline Plus

... Exercises: Day and Night Classroom Exercises: Pinhole Focusing 3D Vision and Eye Health < Contact Lenses Monovision Playlist: ...

174

Debris Dispersion Model Using Java 3D  

Science.gov (United States)

This paper describes web based simulation of Shuttle launch operations and debris dispersion. Java

2004-01-01

175

Contact Lenses  

Medline Plus

... Exercises: Day and Night Classroom Exercises: Pinhole Focusing 3D Vision and Eye Health < Caring for Your Vision ...

177

Instability of 4f and 3d magnetic moments under high pressure  

International Nuclear Information System (INIS)

The purpose of this paper is to demonstrate how recent experimental results of "1"5"1Eu and "5"7Fe high pressure Moessbauer studies in 4f and 3d metallic magnetic systems can contribute to a deeper understanding of the nature of local moment (4f) and itinerant (3d) magnetism in these systems. Special emphasis is given on the comparison of the experimental results with related theoretical models. (orig.).

178

Competitive degradation between the fumigants chloropicrin and 1,3-dichloropropene in unamended and amended soils.  

Science.gov (United States)

The mixture of 1,3-dichloropropene (1,3-D) and chloropicrin (CP) is used as a preplant soil fumigant. In comparison with individual fumigants, application of a mixture may affect the environmental dissipation and fate of each chemical, such as emission and degradation. We investigated the degradation of CP, 1,3-D, and their mixture in fresh soils and sterile soils, and evaluated the competitive characteristic of fumigants in the mixture. The degradation of low concentrations of CP in fresh soil was accelerated at early times in the presence of 1,3-D, whereas the addition of CP reduced the degradation rate of trans-1,3-D, possibly by inhibiting the activity of trans-1,3-D degrading microorganisms. The potential of applying amendments to the soil to increase the rate of CP and ...

179

Calculated valence electronic structure of 3d metals for use in the X-ray intensity ratio studies  

Energy Technology Data Exchange (ETDEWEB)

3d occupation numbers of the transition elements corresponding to various types of atomic configurations are calculated by means of the linear muffin-tin orbital (LMTO) method. This data is used with the multiconfiguration Dirac-Fock (MCDF) X-ray intensity ratios to estimate the electron populations of the 3d metals in alloys.

2010-09-15

180

Calculated valence electronic structure of 3d metals for use in the X-ray intensity ratio studies  

International Nuclear Information System (INIS)

3d occupation numbers of the transition elements corresponding to various types of atomic configurations are calculated by means of the linear muffin-tin orbital (LMTO) method. This data is used with the multiconfiguration Dirac-Fock (MCDF) X-ray intensity ratios to estimate the electron populations of the 3d metals in alloys.

2010-09-01

181

Determination of anisotropic velocity model by reflection tomography of compression and shear modes; Determination de modele de vitesse anisotrope par tomographie de reflexion des modes de compression et de cisaillement  

Energy Technology Data Exchange (ETDEWEB)

As the jump from 2D to 3D, seismic exploration lives a new revolution with the use of converted PS waves. Indeed PS converted waves are proving their potential as a tool for imaging through gas; lithology discrimination; structural confirmation; and more. Nevertheless, processing converted shear data and in particular determining accurate P and S velocity models for depth imaging of these data is still a challenging problem, especially when the subsurface is anisotropic. To solve this velocity model determination problem we propose to use reflection travel time tomography. In a first step, we derive a new approximation of the exact phase velocity equation of the SV wave in anisotropic (TI) media. This new approximation is valid for non-weak anisotropy and is mathematically simpler to handle than the exact equation. Then, starting from an isotropic reflection tomography tool developed at Lt-'P, ...

2001-12-01

182

A study of image-guided radiotherapy of bladder cancer based on lipiodol injection in the bladder wall  

Energy Technology Data Exchange (ETDEWEB)

Purpose. We have tested a procedure of focal injection of the contrast medium Lipiodol as a fiducial marker for image-guided boost of the tumor in bladder cancer radiotherapy (RT). In this study, we have evaluated the feasibility and the safety of the method as well as the inter- and intra-fraction shift of the bladder tumor. Materials and methods. Five patients with muscle invasive urinary bladder cancer were included in the study. Lipiodol was injected during flexible cystoscopy into the submucosa of the bladder wall at the periphery of the tumor or the post resection tumor-bed. Cone-beam CT (CBCT) scans were acquired daily throughout the course of RT. Results. Lipiodol demarcation of the bladder tumor was feasible and safe with only a minimum of side effects related to the procedure. The Lipiodol spots were visible on CT and CBCT scans for the duration of the RT course. More than half of all the treatment fractions required a geometric shift of 5 mm or more to ...

2010-10-15

183

A High-Frequency Secondary Event During the 2004 M6.0 Parkfield Earthquake  

Science.gov (United States)

We present an image of the rupture propagation of the 2004 M6.0 Parkfield earthquake using records from a dense network of local strong motion stations. We back-propagate high-frequency waveforms in 3D with a method, similar to reverse time migration, to obtain an estimate of the distribution of radiated high-frequency seismic energy in space and time. The image is forced to be coherent at the known hypocenter location and the quake origin time by applying small static time shifts obtained using waveform cross-correlation. We observe that the Parkfield earthquake radiated a distinct secondary high-frequency phase, which is located about 12.5~km northwest of the hypocenter with an onset of seismic radiation about 5~s after the rupture initiation. The time history of the back-projection suggests a rupture velocity of 2.5~km/s between hypocenter and subevent. The back-projection result is confirmed by ...

2007-12-01

184

Feasibility study of computed tomography colonography using limited bowel preparation at normal and low-dose levels study  

Energy Technology Data Exchange (ETDEWEB)

The purpose was to evaluate low-dose CT colonography without cathartic cleansing in terms of image quality, polyp visualization and patient acceptance. Sixty-one patients scheduled for colonoscopy started a low-fiber diet, lactulose and amidotrizoic-acid for fecal tagging 2 days prior to the CT scan (standard dose, 5.8-8.2 mSv). The original raw data of 51 patients were modified and reconstructed at simulated 2.3 and 0.7 mSv levels. Two observers evaluated the standard dose scan regarding image quality and polyps. A third evaluated the presence of polyps at all three mSv levels in a blinded prospective way. All observers were blinded to the reference standard: colonoscopy. At three times patients were given questionnaires relating to their experiences and preference. Image quality was sufficient in all patients, but significantly lower in the cecum, sigmoid and rectum. The two observers correctly ...

2007-12-15

185

Detection of pollution-induced forest decline in the Kola Peninsula using remote sensing and mathematical modelling  

Energy Technology Data Exchange (ETDEWEB)

Forests on the Kola Peninsula in Northern Russia grow close to the northern tree line. They are subjected to both natural and anthropogenic stress factors. The Cu-Ni smelter 'Severonikel' (Lat. 67 deg 55'N; Long. 32 deg 57'E) near Monchegorsk is one of the two major sources of sulphur dioxide and heavy metals emissions on the Kola Peninsula. These emissions have caused significant deterioration of the surrounding vegetation. The thesis demonstrates how methods of Remote sensing, ground survey and mathematical modelling can be integrated for monitoring of the smelter's environmental impact on the surrounding vegetation: ground truth data are used for calibration of remote-sensed data, which further serve to verify mathematical models. The study aims were: * to estimate the scale of airborne sulphur pollution from the smelting industry on the Kola Peninsula and its effect on vegetation; * to assess spatial extent of the forest decline in the ...

1998-07-01

186

A proposition of 3D inertial tolerancing to consider the statistical combination of the location and orientation deviations  

CERN Document Server

Tolerancing of assembly mechanisms is a major interest in the product life cycle. One can distinguish several models with growing complexity, from 1-dimensional (1D) to 3-dimensional (3D) (including form deviations), and two main tolerancing assumptions, the worst case and the statistical hypothesis. This paper presents an approach to 3D statistical tolerancing using a new acceptance criterion. Our approach is based on the 1D inertial acceptance criterion that is extended to 3D and form acceptance. The modal characterisation is used to describe the form deviation of a geometry as the combination of elementary deviations (location, orientation and form). The proposed 3D statistical tolerancing is applied on a simple mechanism with lever arm. It is also compared to the traditional worst-case tolerancing using a tolerance ...

2010-01-01

187

3-D depth migration via McClellan transformations  

Energy Technology Data Exchange (ETDEWEB)

Three-dimensional seismic wavefields may be extrapolated in depth, one frequency at a time, by two-dimensional convolution with a circularly symmetric, frequency- and velocity-dependent filter. This depth extrapolation, performed for each frequency independently, lies at the heart of 3-D finite-difference depth migration. The computational efficiency of 3-D depth migration depends directly on the efficiency of this depth extrapolation. McClellan transformations provide an efficient method for both designing and implementing two-dimensional digital filters that have a particular form of symmetry, such as the circularly symmetric depth extrapolation filters used in 3-D depth migration. Given the coefficients of one-dimensional, frequency- and velocity-dependent filters used to accomplish 2-D depth migration, McClellan transformations lead to a simple and efficient ...

1990-01-01

188

A Simulation Study on a Radioactive Nuclide's Distribution within a Fuel rod by a Tomographic Gamma Scanning  

Energy Technology Data Exchange (ETDEWEB)

Gamma scanning measurements are used to determine the radioactive nuclides from an irradiated fuel rod in a hot cell which is a routine task in the Irradiated Materials Examination Facility (IMEF) of the Korea Atomic Energy Research Institute (KAERI), Total gamma spectra of radioactive nuclides and the atomic ratio of {sup 134}Cs to {sup 137}Cs in a few segments of a single fuel rod are measured by the present gamma scanning system. For the purpose of determining the radioactive nuclide's distribution in detail within a fuel rod quantitatively, we attempt to upgrade the present gamma scanning system in this paper, therefore, an investigation of the feasibility of the tomographic gamma scanning (TGS) technique, which is one of the promising nondestructive assay (NDA) methods is proposed. The TGS technique is an efficient method and it has an accurate precision for the characterization of several fuel parameters. In this paper, a principle and an emission TGS and an iterative ...

2006-07-01

189

Structural and transport properties of illitized samples from drillhole OL-KR12 in Olkiluoto. Porosity, diffusion coefficient, permeability and tomographic imaging  

Energy Technology Data Exchange (ETDEWEB)

Six illitized samples from drillhole OL-KR12 in Olkiluoto were analyzed by helium gas methods for their diffusion coefficient, permeability and porosity. The diffusion coefficients measured varied in the range 2.1 x 10-10 - 3.5 x 10-8 m2/s, permeabilities in the range 6 x 10-21 - 5.8 x 10-16 m2, and porosities in the range 0.2 6.2%. Variations observed in these quantities were concluded to arise from the heterogeneous structure of the sample rock. A 4 mm x 4 mm x 4 mm subsample was sawed from each of the six samples for structural analysis by x-ray microtomography. The three-dimensional structure of tomographic reconstructions, and thereby that of the samples themselves, was analyzed visually, which confirmed their heterogeneity. Samples represent altered rock whose structure and thereby transport properties vary significantly depending on the local alteration history of the rock. (orig.)

2009-10-15

190

Free-electron laser beam  

International Nuclear Information System (INIS)

The principle and history of free-electron laser (FEL), first evidenced in 1977, the relationship between FEL wavelength and output power, the high-power FEL driven by the superconducting linac, the X-ray FEL by the linac, and the medical use are described. FEL is the vacuum oscillator tube and essentially composed from the high-energy linac, undulator and light-resonator. It utilizes free electrons in the vacuum to generate the beam with wavelength ranging from microwave to gamma ray. The first high-power FEL developed in Japanese Atomic Energy Research Institute (JAERI) is based on the development of superconducting linac for oscillating the highest power beam. In the medical field, applications to excise brain tumors (in US) and to reconstruct experimentally blood vessels in the pig heart (in Gunma University) by lasing and laser coagulator are in progress with examinations to remove intra-vascular cholesterol mass by irradiation of 5.7#mu#m FEL beam. Cancer ...

2003-06-01

191

Determination of the initial energy in computerized tomography with proton beams; Determinacao da energia inicial em tomografia computadorizada com feixe de protons  

Energy Technology Data Exchange (ETDEWEB)

In earliest works devoted to proton computed tomography it was shown that the advantage of pCT image reconstruction appears when the energy is close to the Bragg peak region, since the proton passes the object. This effect provided by the Bragg peak makes the computerized tomography with protons possible. However, when decreasing the initial proton energy, with the increase of the irradiation dose, there are two effects that work simultaneously in opposite ways. First, the energy loss of a proton in an object becomes bigger at small initial energy. At the same time decreasing of the proton energy results in the increase of the energy straggling, requiring a larger number of protons. In this work the radiation dose dependence on the proton initial energy was studied using analytical formulas and computer simulations. The investigation determined that the radiation dose practically does not depend on the initial energy, except in the energy ...

2007-07-01

192

Detection of Second-Layer Corrosion in Aging Aircraft Fuselage  

International Nuclear Information System (INIS)

A Digital X-ray imaging system using Compton backscattering has been developed to obtain a cross-sectional profile and mass loss of corroded lap-splices of aging aircraft from density variation. A slit-type camera was designed to focus on a small scattering volume inside the material, from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the lap-joint is scanned by moving the scattering volume through the thickness direction of the specimen. The mass loss of each layer has been estimated from a Compton backscatter A-scan to obtain the thickness of each layer including the aluminum sheet, the corrosion layer and the sealant. Quantitative information such as location and width of planar corrosion in the lap splices of fuselages is obtained by deconvolution using a nonlinear least-square error minimization method(BFGS method): A simple ...

2006-12-01

193

Magnetic resonance imaging of stents. Quantitative in vitro examination at 3 Tesla; Magnetresonanztomographie von Stents. Quantitative MR-Untersuchungen in vitro bei 3 Tesla  

Energy Technology Data Exchange (ETDEWEB)

The aim of this study was to qualitatively and quantitatively study MR artifacts of various stents on the basis of in vitro experiments. We were particularly interested whether sequence type and orientation of the stent with respect to the static magnetic field influences the artifact. We examined 18 stents of different material (nitinol, stainless steel, cobalt alloy), different design of the stent meshes (AccuLink, OmniLink, DynaLink, Xact, Protoge, Wallstent Monorail), different diameter (5-10 mm) and different length (18-58 mm) with a turbo spin echo (TSE), a 2D-fast low angle shot (FLASH) and a 3D-FLASH sequence. The MR images were examined qualitatively with respect to possible artifacts. Furthermore we examined the MR data quantitatively: The contrast-noise-ratio (CNR) was determined both within the stent and outside (within the tube); based on these values we calculated the transparency factor P, furthermore we ...

2009-07-01

194

Daily cone-beam computed tomography used to determine tumour shrinkage and localisation in lung cancer patients  

Energy Technology Data Exchange (ETDEWEB)

Purpose/Objective. Daily Cone-beam computed tomography (CBCT) in room imaging is used to determine tumour shrinkage during a full radiotherapy (RT) course. In addition, relative interfractional tumour and lymph node motion is determined for each RT fraction. Material and methods. From November 2009 to March 2010, 20 consecutive lung cancer patients (14 NSCLC, 6 SCLC) were followed with daily CBCT during RT. The gross tumour volume for lung tumour (GTV-t) was visible in all daily CBCT scans and was delineated at the beginning, at the tenth and the 20th fraction, and at the end of treatment. Whenever visible, the gross tumour volume for lymph nodes (GTV-n) was also delineated. The GTV-t and GTV-n volumes were determined. All patients were setup according to an online bony anatomy match. Retrospectively, matching based on the internal target volume (ITV), the GTV-t or the GTV-n was performed. Results. In eight patients, we observed a significant GTV-t shrinkage ...

2010-10-15

195

CT colonography: techniques of visualization and findings; CT Kolonographie: Techniken der Visualisierung und Befundung  

Energy Technology Data Exchange (ETDEWEB)

Evaluation and interpretation of CT colonography is based on both 2D and 3D techniques. The 2D techniques are popular mainly because the time needed for evaluation is short. The 3D techniques allow better definition than the 2D techniques, especially of polyps close to folds or at the base of a fold. The evaluation strategies generally accepted so far (primarily 2D, with 3D for problem cases, or vice versa) demand knowledge of both 2D and 3D techniques. Newer 3D visualization techniques help make it possible to acquire more complete and faster recording particularly of areas that are not easily accessible to endoscopic examination. These user-friendly developments are thus well suited to improving the detection and the security of detection of polyps. It must be remembered that ...

2008-02-15

196

The use of EPID-measured leaf sequence files for IMRT dose reconstruction in adaptive radiation therapy  

UK PubMed Central (United Kingdom)

For intensity modulated radiation treatment (IMRT) dose reconstruction, multileaf collimator (MLC) log files have been shown applicable for deriving delivered fluence maps. However, MLC log files are...Full Text Available

2008-11-01

197

SEER Treatment Field Names, Edition Numbers, NAACCR Data Item Name,  

Science.gov (United States)

In addition, for breast cancer, a fifth field, Reconstruction--First Course is recorded. V.02.E Reconstruction--First Course (breast only) 1 digit These codes for these fields are included as Appendix C of this manual.

198

Nuclear Pore Complex Number and Distribution throughout the Saccharomyces cerevisiae Cell Cycle by Three-Dimensional Reconstruction from Electron Micrographs of Nuclear Envelopes  

UK PubMed Central (United Kingdom)

The number of nuclear pore complexes (NPCs) in individual nuclei of the yeast Saccharomyces cerevisiae was determined by computer-aided reconstruction of entire nuclei from electron...Full Text Available

1997-11-01

199

Integration of metabolic databases for the reconstruction of genome-scale metabolic networks  

UK PubMed Central (United Kingdom)

BackgroundGenome-scale metabolic reconstructions have been recognised as a valuable tool for a variety of applications ranging from metabolic engineering to evolutionary studies....Full Text Available

200

Hominin life history: reconstruction and evolution  

UK PubMed Central (United Kingdom)

In this review we attempt to reconstruct the evolutionary history of hominin life history from extant and fossil evidence. We utilize demographic life history theory and distinguish life history variables,...Full Text Available

2008-04-01

201

Distinguishing between parenchymal and anastomotic leakage at duct-to-mucosa pancreatic reconstruction in pancreaticoduodenectomy  

UK PubMed Central (United Kingdom)

AIM: To distinguish anastomotic from parenchymal leakage at duct-to-mucosa reconstruction of the pancreatic remnant.METHODS: We reviewed the charts of 68 pancreaticod-uodenectomies performed...Full Text Available

2008-11-21

202

Dendrochronological Mass Balance Reconstruction, Strathcona Provincial Park, Vancouver Island, British Columbia, Canada  

Science.gov (United States)

... 036[0598:DMBRSP]2.0.CO;2 Dendrochronological Mass Balance Reconstruction, Strathcona Provincial Park, Vancouver Island, British ...

203

Comparable Results Between Lateralized Single- and Double-bundle ACL Reconstructions  

UK PubMed Central (United Kingdom)

Patellar tendon autografts are not suitable for multibundle ACL reconstruction, a procedure that reportedly enhances postoperative knee stability. Biomechanical studies recommend lateral placement of...Full Text Available

2009-04-01

204

An improved model for natural convection heat loss from modified cavity receiver of solar dish concentrator  

Energy Technology Data Exchange (ETDEWEB)

A 2-D model has been proposed to investigate the approximate estimation of the natural convection heat loss from modified cavity receiver of without insulation (WOI) and with insulation (WI) at the bottom of the aperture plane in our previous article. In this paper, a 3-D numerical model is presented to investigate the accurate estimation of natural convection heat loss from modified cavity receiver (WOI) of fuzzy focal solar dish concentrator. A comparison of 2-D and 3-D natural convection heat loss from a modified cavity receiver is carried out. A parametric study is carried out to develop separate Nusselt number correlations for 2-D and 3-D geometries of modified cavity receiver for estimation of convective heat loss from the receiver. The results show that the 2-D and 3-D are comparable only at higher angle of ...

2009-10-15

205

CMS Silicon Strip Tracker Performance  

CERN Document Server

In this paper we describe the reconstruction strategies, the calibration procedures and the detector performance results from the latest CMS operation.

2011-01-01

206

Collaboration work for nuclear power building using 3D CAD information  

Energy Technology Data Exchange (ETDEWEB)

In the construction work for the Unit No.5 Turbine Building at Hamaoka Nuclear Power Station, the collaboration work for the planning and the coordination of the building construction and the machinery installation was carried out utilizing three-dimensional computer aided design (3D CAD) information. It was the first time in Japan for a building constructor and a plant manufacturer to work together, exchanging 3D CAD data of the whole building and adjusting the construction schedule. It was made possible to confirm the correspondence concerning the planning of both companies from the primary stage of the project by the total process simulation and to adjust on-going work precisely by the partial process simulation.

2006-02-15

207

Collaboration work for nuclear power building using 3D CAD information  

International Nuclear Information System (INIS)

In the construction work for the Unit No.5 Turbine Building at Hamaoka Nuclear Power Station, the collaboration work for the planning and the coordination of the building construction and the machinery installation was carried out utilizing three-dimensional computer aided design (3D CAD) information. It was the first time in Japan for a building constructor and a plant manufacturer to work together, exchanging 3D CAD data of the whole building and adjusting the construction schedule. It was made possible to confirm the correspondence concerning the planning of both companies from the primary stage of the project by the total process simulation and to adjust on-going work precisely by the partial process simulation.

2006-02-01

208

Global quantum gauge symmetry via reconstruction theorems  

Energy Technology Data Exchange (ETDEWEB)

In this paper we establish that every quantum field theory satisfying some basic axioms possesses a weak quasi Hopf algebra as gauge symmetry. We use a reconstruction theorem to find this symmetry algebra and show how it is sed to build a gauge covariant field algebra. We investigate the question of why this generality is necessary. The non-uniqueness of the reconstruction process is interpreted and a cohomological classification of possible global gauge symmetries is given. (author)

1996-12-21

209

Technical Evaluation Report  

Science.gov (United States)

... and/or hearing mechanisms. Seven papers dealt with 3D audio technology and/or its application. Eight papers presented ...

2005-04-01

210

Tackling the Steroid Issue: Squeezing Out the Juice  

Medline Plus

... Neglect (12) Co-Occurring Disorders (75) Conduct Disorders (3) D Dementia (2) Depression (51) Driving While Intoxicated (17) ...

211

English version - Guidelines for Viability Assessment - CAP Workbook version 3_d  

Science.gov (United States)

Guidelines for the viability primer component of the version 3 workbook. The Viability page in the current version of the Excel spreadsheet for conservation ... ...

214

An improved model for natural convection heat loss from modified cavity receiver of solar dish concentrator  

British Library Electronic Table of Contents (United Kingdom)

A 2-D model has been proposed to investigate the approximate estimation of the natural convection heat loss from modified cavity receiver of without insulation (WOI) and with insulation (WI) at the bottom of the aperture plane in our previous article. In this paper, a 3-D numerical model is presented to investigate the accurate estimation of natural convection heat loss from modified cavity receiver (WOI) of fuzzy focal solar dish concentrator. A comparison of 2-D and 3-D natural convection heat loss from a modified cavity receiver is carried out. A parametric study is carried out to develop separate Nusselt number correlations for 2-D and 3-D geometries of modified cavity receiver for estimation of convective heat loss from the receiver. The results show that the 2-D and 3-D are comparabl...

2009-01-01

215

Advanced 3D Visualization Web Technology and its Use in ...  

Science.gov (United States)

... applications related to military and intelligence area ... the technology solved yet, but the open issue still ... fields, columns; ie data source, document type ...

2002-04-01

216

AIAA 20033400 CFD Sensitivity Analysis ... - FUN3D Manual - NASA  

Science.gov (United States)

mulation, with flow quantities stored at the grid vertices. OVERFLOW ..... attack: a separation bubble near the trailing edge of the ..... AGARD CP-429, Jul. 1988. ...

218

Multidimensional B-spline parameterization of the detection probability of PET systems to improve the efficiency of Monte Carlo simulations  

International Nuclear Information System (INIS)

Accurate modeling of system response and scatter distribution is crucial for image reconstruction in emission tomography. Monte Carlo simulations are very well suited to calculate these quantities. However, Monte Carlo simulations are also slow and many simulated counts are needed to provide a sufficiently exact estimate of the detection probabilities. In order to overcome these problems, we propose to split the simulation into two parts, the detection system and the object to be imaged (the patient). A so-called 'virtual boundary' that separates these two parts is introduced. Within the patient, particles are simulated conventionally. Whenever a photon reaches the virtual boundary, its detection probability is calculated analytically by evaluating a multi-dimensional B-spline that depends on the photon position, direction and energy. The unknown B-spline knot values that define this B-spline are fixed by a prior 'pre-' ...

2010-06-21

219

Feasibility of ultra-low-dose multislice CT colonography for the detection of colorectal lesions: preliminary experience  

Energy Technology Data Exchange (ETDEWEB)

Our objective was to evaluate the feasibility of ultra-low-dose scanning for multislice CT colonography in the detection of colorectal lesions. Twenty-seven patients (14 men, 13 women) with clinical indication for conventional colonoscopy were recruited. Multislice spiral CT (Somatom Plus 4 Volume Zoom, Siemens, Germany) examinations were performed after standard oral colonoscopic preparation and colonic distension with room air. Images were acquired using 2.5-mm collimation, 3.0-mm slice thickness, standard reconstruction kernel, 140 kVp, and 10 mAs. Supine and prone acquisitions were obtained in all patients. Images were analyzed on a workstation by two gastrointestinal radiologists. Conventional colonoscopy was performed on the same day in all patients and represented the standard of reference. Total radiation exposure was also calculated. All colorectal cancers were correctly identified at CT colonography (9 of 9, ...

2003-06-01

220

Automatic segmentation of thoracic and pelvic CT images for radiotherapy planning using implicit anatomic knowledge and organ-specific segmentation strategies  

Energy Technology Data Exchange (ETDEWEB)

Automatic segmentation of anatomical structures in medical images is a valuable tool for efficient computer-aided radiotherapy and surgery planning and an enabling technology for dynamic adaptive radiotherapy. This paper presents the design, algorithms and validation of new software for the automatic segmentation of CT images used for radiotherapy treatment planning. A coarse to fine approach is followed that consists of presegmentation, anatomic orientation and structure segmentation. No user input or a priori information about the image content is required. In presegmentation, the body outline, the bones and lung equivalent tissue are detected. Anatomic orientation recognizes the patient's position, orientation and gender and creates an elastic mapping of the slice positions to a reference scale. Structure segmentation is divided into localization, outlining and refinement, performed by procedures with implicit ...

2008-03-21

221

The denoising of Monte Carlo dose distributions using convolution superposition calculations  

International Nuclear Information System (INIS)

Monte Carlo (MC) dose calculations can be accurate but are also computationally intensive. In contrast, convolution superposition (CS) offers faster and smoother results but by making approximations. We investigated MC denoising techniques, which use available convolution superposition results and new noise filtering methods to guide and accelerate MC calculations. Two main approaches were developed to combine CS information with MC denoising. In the first approach, the denoising result is iteratively updated by adding the denoised residual difference between the result and the MC image. Multi-scale methods were used (wavelets or contourlets) for denoising the residual. The iterations are initialized by the CS data. In the second approach, we used a frequency splitting technique by quadrature filtering to combine low frequency components derived from MC simulations with high frequency components derived from CS components. The rationale is to take the scattering ...

2007-09-07

222

Submarine tsunamigenic landslides at Stromboli Volcano: characterization and estimation of recurrence time  

Science.gov (United States)

Seafloor mapping and morphometric analysis of landslide scars can provide useful insights for marine geo-hazard assessment, as demonstrated by several studies performed on different geological settings. The availability of high-resolution multibeam bathymetry and long-range side scan sonar data on the submarine portions of Stromboli Volcano allow us to map and characterize the main mass-wasting features that affect, on the whole, about the 90% of its submarine extension. In particular, two main kinds of tsunamigenic landslides have been recognized and analyzed. Large-scale sector collapses (Fig. 1) are catastrophic events that mobilize 1-2 cubic kilometers of material, generating huge tsunami waves that may affect Stromboli and propagate in surrounding areas; related hazard is not very high, as they show recurrence periods of some (or more) thousand years. Conversely, medium-scale landslides are more hazardous, as they occur at higher frequency with respect to the previous events, i.e. ...

2010-12-01

223

High-resolution "1H magnetic resonance spectroscopy imaging at 1.5 and 3 Tesla of the human brain: development of techniques and applications for patients with primary brain tumors and multiple sclerosis  

International Nuclear Information System (INIS)

The aim of this work was to develop several strategies and software-packages for the evaluation of in-vivo-data of the human brain, which were acquired with high-resolution 1H-MRSI at 1.5 and 3 T. Several studies involving phantoms, volunteers and patients were performed. Quality assurance studies were conducted in order to evaluate the reproducibility of the applied MR-techniques at both field strengths. A qualitative comparison-study between MRSI-data from a 1.5 T clinical MR-scanner and a 3 T research MR-scanner showed the advantages of the more advanced MRSI sequences and higher field strength (3 T). A study involving patients with primary brain tumours (gliomas) was performed in cooperation with the Department of Neurosurgery (University of Erlangen-Nuremberg). The methods developed in the course of this study, such as the integration of MRS-data into a stereotactic-system, the segmentation of metabolic maps and the correlation with histopathological findings represent a package ...

224

Experience and recent developments in nuclear forensics at the Institute of Isotopes  

International Nuclear Information System (INIS)

Full text: Based on experience with nuclear material confiscated in Hungary from illicit trafficking activities in the nineties it has been decided that traditional gamma-spectrometry should be complemented by destructive analytical techniques. The 17/1996 (I. 31.) Korm. Governmental Decree delegated the identification, categorization and characterization tasks to the Institute of Isotopes, Budapest. Routine gamma-spectrometric methods have been further developed aiming at the i) age (production date) determination of seized samples and complete (nondismountable) uranium-bearing items (such as fresh fuel bundles and fission chambers) by HRGS technique, ii) improvement of measurement accuracy and reliability. Starting in 2005 mass spectrometry (ICP-SFMS) and scanning electron microscopy have been implemented to characterize nuclear samples in more detail and to analyze environmental samples both for isotopic and elemental composition focusing on long-lived radioactive isotopes including ...

225

Developmental cortical thinning in fetal alcohol spectrum disorders.  

Science.gov (United States)

Regional cortical thickness was evaluated using CIVET processing of 3D T1-weighted images (i) to compare the variation in cortical thickness between 33 participants with fetal alcohol spectrum disorders (FASD) aged 6-30 years (mean age 12.3 years) versus 33 age/sex/hand-matched controls, and (ii) to examine developmental changes in cortical thickness with age from children to young adults in both groups. Significant cortical thinning was found in the participants with FASD in large areas of the bilateral middle frontal lobe, pre- and post- central areas, lateral and inferior temporal and occipital lobes compared to controls. No significant cortical thickness increases were observed for the FASD group. Cortical thinning with age in a linear model was observed in both groups, but the locations were different for each group. FASD participants showed thinning with age in the left middle frontal, bilateral precentral, bilateral ...

2011-06-17

226

Development of an efficient parallel FEM analysis program for large structural problems over several millions of DOF  

International Nuclear Information System (INIS)

In order to predict or to evaluate the structural reliability of a variety of nuclear components under actual changing operating conditions, it is necessary to take the detailed geometrical features of components into consideration on one hand, and thermo-mechanical loading conditions with space and time variations during the lifetime, on the other hand. This consideration leads the authors to develop a super large-scale structural analysis program based on a parallel computational FEM with a variable scale of PC cluster architecture, whose prototype system is presented in a companion paper in this Symposium. Development of the PC cluster technology is one of the most important subjects in large-scale structural simulation, reducing computer costs and thus making simulation more acceptable to the engineering community. This paper presents the developmental status of the parallel FEM solver, demonstrating computational capabilities with three dimensional effects taking into ...

2000-09-01

227

Characterization of pore structure in cement-based materials using pressurization-depressurization cycling mercury intrusion porosimetry (PDC-MIP)  

International Nuclear Information System (INIS)

Numerous mercury intrusion porosimetry (MIP) studies have been carried out to investigate the pore structure in cement-based materials. However, the standard MIP often results in an underestimation of large pores and an overestimation of small pores because of its intrinsic limitation. In this paper, an innovative MIP method is developed in order to provide a more accurate estimation of pore size distribution. The new MIP measurements are conducted following a unique mercury intrusion procedure, in which the applied pressure is increased from the minimum to the maximum by repeating pressurization-depressurization cycles instead of a continuous pressurization followed by a continuous depressurization. Accordingly, this method is called pressurization-depressurization cycling MIP (PDC-MIP). By following the PDC-MIP testing sequence, the volumes of the throat pores and the corresponding ink-bottle pores can be determined at every pore size. These values are used to calculate pore size ...

2010-07-01

228

Basic study of entire whole-body PET scanners based on the OpenPET geometry  

International Nuclear Information System (INIS)

A conventional PET scanner has a 15-25 cm axial field-of-view (FOV) and images a whole body using about six bed positions. An OpenPET geometry can extend the axial FOV with a limited number of detectors. The entire whole-body PET scanner must be able to process a large amount of data effectively. In this work, we study feasibility of the fully 3D entire whole-body PET scanner using the GATE simulation. The OpenPET has 12 block detector rings with the ring diameter of 840 mm and each block detector ring consists of 48 depth-of-interaction (DOI) detectors. The OpenPET has the axial length of 895.95 mm with five parts of 58.95 mm open gaps. The OpenPET has higher single data loss than a conventional PET scanner at grouping circuits. NECR of the OpenPET decreases by single data loss. But single data loss is mitigated by separating the axially arranged detector into two parts. Also, multiple coincidences are found to be ...

2010-09-01

229

Transplantation of engineered bone tissue using a rotary three-dimensional culture system.  

Science.gov (United States)

Bone is a complex, highly structured, mechanically active, three-dimensional (3-D) tissue composed of cellular and matrix elements. We previously published a report on in situ collagen gelation using a rotary 3-D culture system (CG-RC system) for the construction of large tissue specimens. The objective of the current study was to evaluate the feasibility of bone tissue engineering using our CG-RC system. Osteoblasts from the calvaria of newborn Wistar rats were cultured in the CG-RC system for up to 3 wk. The engineered 3-D tissues were implanted into the backs of nude mice and calvarial round bone defects in Wistar rats. Cell metabolic activity, mineralization, and bone-related proteins were measured in vitro in the engineered 3-D tissues. Also, the in vivo histological features of the transplanted, engineered ...

2007-03-11

230

Topological excitations and second order transitions in 3D O(N) models  

Energy Technology Data Exchange (ETDEWEB)

I discuss several examples of critical phenomena in O(N) models where topological excitations play an important role at criticality. I focus particular attention on the O(2) model in 3D, where recent measurements of the vortex string length distribution in equilibrium suggest the existence of a quantitative picture of the critical behavior in terms of defects. The compatibility of this perspective with renormalization group predictions is examined.

2001-01-01

231

T-HEMP3D, 3-D Time-Dependent Elastic Plastic Flow  

International Nuclear Information System (INIS)

1 - Description of program or function: T-HEMP3D (Transportable HEMP3D) is a derivative of the STEALTH three-dimensional thermodynamics code developed by Science Applications, Inc. Changes were made primarily in three areas: material specification, coordinate generation, and the addition of sliding surface boundary conditions. STEALTH itself is based entirely on the HEMP3D code written at LLNL. HEMP3D solves problems in solid mechanics involving dynamic plasticity and time-dependent material behavior and problems in gas dynamics. 2 - Method of solution: The equations of motion, conservation equations, and constitutive relations for stresses, strains, hydrostatic pressure, the von Mises yield condition, and artificial viscosity are solved by finite difference methods following the format of the HEMP code (NESC Abstract ...

232

Sequence specificity of the non-natural pyrido[2,3-d]pyrimidine nucleoside in triple helix formation.  

UK PubMed Central (United Kingdom)

The non-natural pyrido[2,3-d]pyrimidine nucleoside F, which pairs preferentially with guanine (G) and adenine (A) within double-helical DNA, recognizes with high selectivity AT base pairs within triple-helical...Full Text Available

1994-07-11

233

Pd-Na/F double exploding foil photoionization experiment  

Science.gov (United States)

The achievement of inner-shell photoionization of Zn-like Pd by means of two exploding foils is described. This resulted in the soft X-ray transition 3d94s2-3d104p at 46 A. It is shown that the photoionization of inner shell electrons in highly stripped ions can lead to X-ray transitions which may be candidates for X-ray lasers under 50 A.

1990-03-01

234

On the Metastable Level in Ni-like Ions  

Energy Technology Data Exchange (ETDEWEB)

The lowest excited level in Ni-like ions, 3d{sup 9}4s {sup 3}D{sub 3}, decays only via a magnetic octupole (M3) decay. They present calculated values of transition wavelengths and rates for ions with 30 {le} Z {le} 100. They have observed this line in Xe{sup 26+}, using the Livermore EBIT-I electron beam ion trap and a microcalorimeter, as well as a high-resolution flat-field grating spectrometer.

2004-09-14

235

K_#beta#/K_#alpha# X-Ray Intensity Ratio Studies on the Valence Electronic States of 3d-Transition Metals in some of their Compounds  

International Nuclear Information System (INIS)

Our studies on K#beta#/K#alpha# X-ray intensity ratios of some of the technologically important 3d-transition metal compounds have been reviewed. Comparison of the experimental results with single-configuration Dirac-Fock calculations provided important information on the valence states of the transition metals in various compounds, which can be helpful in understanding the nature of bonding in the compounds. (author)

2000-02-01

236

Chemical sensitivity of the Ksub(. beta. )/Ksub(. cap alpha. ) x-ray intensity ratio for 3d elements  

Energy Technology Data Exchange (ETDEWEB)

Chemical influences on the relative Ksub(..beta..)/Ksub(..cap alpha..) x-ray intensity ratio up to five per cent were found for different chemical constitutions of Cr, Mn, Fe and Cu by very precise PIXE measurements. In the discussion of these effects, screening of 3p electrons by a varying 3d valence charge, as well as polarizational effects are of importance.

1982-12-28

237

Chemical sensitivity of the Ksub(#nu#)/Ksub(#alpha#) x-ray intensity ratio for 3d elements  

International Nuclear Information System (INIS)

Chemical influences on the relative Ksub(#nu#)/Ksub(#alpha#) x-ray intensity ratio up to five per cent were found for different chemical constitutions of Cr, Mn, Fe and Cu by very precise PIXE measurements. In the discussion of these effects, screening of 3p electrons by a varying 3d valence charge, as well as polarisational effects are of importance. (author).

1982-12-01

238

A 3D tomographic EBSD analysis of a CVD diamond thin film  

Energy Technology Data Exchange (ETDEWEB)

We have studied the nucleation and growth processes in a chemical vapor deposition (CVD) diamond film using a tomographic electron backscattering diffraction method (3D EBSD). The approach is based on the combination of a focused ion beam (FIB) unit for serial sectioning in conjunction with high-resolution EBSD. Individual diamond grains were investigated in 3-dimensions particularly with regard to the role of twinning.

2008-09-15

239

Comparison of contrast-enhanced flash and turbo-flash with conventional spin-echo sequences as a basis for morphologocal MR imaging for planning high-precision radiotherapy of intracranial brain tumors. Comparison of FLASH-, turbo-FLASH and SE-sequences; Morphologische MR-Bildgebung mit T1-gewichteten Sequenzen zur radiotherapeutischen Zielvolumendefinition von intrakraniellen Tumoren. Vergleich von FLASH-, Turbo-FLASH- und SE-Sequenzen  

Energy Technology Data Exchange (ETDEWEB)

Introduction: The goal of this study was to compare contrast-enhanced T1-weighted Flash and Turbo-Flash sequences with conventional spin-echo sequences as a basis for planning high-precision radiotherapy. Methods: A total of 25 consecutive patients with different intracranial tumors and a disrupted blood-brain barrier were studied. T1-weighted Flash, Turbo-Flash and conventional spin-echo images were evaluated after controlled 30-s infusion of 0.1 mmol/kg body weight of Gd-DTPA. The evaluation of the three sequences included the measurement of the signal- and contrast-to-noise ratios, the visual inspection of the tumors and artifacts, and the measurement of tumor size. Results: The signal- and contrast-to-noise ratios were significantly (P<0.05-0.01) lower for Flash and Turbo-Flash than for conventional spin-echo sequences. However, visual inspection of the contrast-enhancing tumors revealed in 23 and 24 of 25 lesions of Flash and Turbo-Flash ...

1997-03-01

240

An efficient method for 3-D pre stack migration in time reverse-time depth by using finite difference method; Um metodo eficiente para migracao pre-empilhamento 3-D em profundidade reversa no tempo pelo metodo das diferencas finitas  

Energy Technology Data Exchange (ETDEWEB)

Much of the current technology on 3D-prestack depth migration is based on the Kirchhoff method and the traveltime information needed for this purpose is obtained by the ray-theory approximation. The main motivation driving these options is to reduce computations but it can also have an adverse effect on the quality of results. Experience with real data indicates that the corresponding poststack data migrated by the reverse-time method often yields superior results. Considerable computational efficiency can be obtained by employing nonuniform coarse grid spacing during the reverse-time migration. We followed this strategy for developing a parallel scheme for doing 3D- prestack depth migration. However, we worked only on a small subset of shot gathers whose determined by the Quasi-Monte Carlo method. The results were indistinguishable from those obtained by using a much larger population of uniformly ...

1997-07-01

241

Atlas of nuclear medicine imaging  

Energy Technology Data Exchange (ETDEWEB)

An exhaustive compendium of normal and abnormal imaging is presented. The following systems and procedures are illustrated by over 2800 captioned illustrations: liver, spleen, and hepatobiliary imaging; perfusion and ventilation lung imaging; thyroid imaging; salivary gland imaging; bone imaging; brain imaging; radionuclide cisternography; blood flow studies; gallium imaging; nuclear cardiology; and renal imaging. Not included in the atlas are adrenal imaging procedures and emission computed tomography. (ERB)

1981-01-01

242

Three-Dimensional Rotational Angiography of the Inferior Vena Cava as an Adjunct to Inferior Vena Cava Filter Retrieval  

International Nuclear Information System (INIS)

The objective of this study was to explore the role of three-dimensional (3-D) rotational angiography (RA) of the inferior vena cava (IVC; 3-D CV) before filter retrieval and its impact on treatment planning compared with standard anteroposterior cavography (sCV). Thirty patients underwent sCV and 3-D CV before IVC filter retrieval. Parameters assessed were: projection of filter arms or legs beyond the caval lumen, thrombus burden within the filter and IVC, and orientation of the filter within IVC. Skin and effective radiation doses were calculated. Statistical analysis was performed using paired Student t test and nonparametric McNemar's test. Standard anteroposterior cavography detected 49 filter arms or legs projecting beyond the caval lumen in 25 patients. Three-dimensional CV demonstrated 89 filter arms or legs projecting beyond the caval lumen in 28 ...

2009-01-01

243

Observation and control of hepatic specimens with MRI and MRS; Beobachtung und Kontrolle von Fixiervorgaengen in Leberpraeparaten mittels MRT und MRS  

Energy Technology Data Exchange (ETDEWEB)

Purpose: The purpose of this study was to observe the process of fixation in liver specimens non-invasively by means of magnetic resonance. The fixation process of several formaldehyde-containing solutions was monitored with MRI and MRS at two different temperatures. Materials and Methods: Liver specimens were conserved in aqueous fixative solutions containing formaldehyde concentrations of 0.7, 1.8, 4 and 7.2% and at different temperatures of 5 C and 20 C. MRI was performed with T1-, T2- and PD-weighted TSE sequences, a 2D FLASH-sequence with and without magnetization transfer, and a FISP 3D-sequence on a clinical 1.5 Tesla MR whole-body unit, and MRS with {sup 1}H-spectroscopic methods (STEAM-sequence) on a 3 Tesla MR whole-body unit. Results: The diffusion of formaldehyde into the tissue was best identified on PD- and T1-weighted images as a band under the liver surface with increasing thickness, penetrating especially ...

2004-04-01

244

SPIO-enhanced MR angiography for the detection of venous thrombosis in an animal model; SPIO-unterstuetzte MR-Angiographie zur Detektion venoeser Thromben im Tiermodell  

Energy Technology Data Exchange (ETDEWEB)

Purpose: An animal model is used to investigate whether MR angiography combined with super-paramagnetic particles of iron oxide (SPIO) is suitable for detecting thromboses. Methods: 42 rats in groups of 7 each were examined on days 1, 3, 5, 7, 9 and 11, respectively, after mechanical/chemical thrombus induction in a 1.5 Tesla magnet with a FISP sequence (TR/TE/FA 50 ms/6 ms/40 ). Imaging was performed before and up to 90 minutes after intravenous injection of 30 {mu}mol FE/kg BW of the experimental SPIO (hydrodynamic diameter, 34{+-}17 nm LLS; R1 and R2 relaxivity at 0.47 T, 31 and 57 L/(mmol*s)). MIP reconstructions of MR angiographies were submitted to consensus assessment by two examiners using histology as the gold standard. Results: The image quality of MIP reconstructions was rated as good in 38 of 42 cases. With regard to thrombotic vessel occlusion, MR angiography coincided with histology in 17 ...

1999-03-01

245

Magnetic resonance imaging. Handbook and atlas; Kernspintomographie. Kompendium und Atlas  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging (MRI) as a diagnostic imaging tool relies on the generation of magnetic fields, whereas the computerized tomography (CT) uses X-radiation. The fundamental principle of MRI is the magnetic resonance of paramagnetic atomic nuclei. These nuclei, as e.g. protons (= hydrogen nuclei), are aligned in required orientation by application of a strong magnetic field. Upon simultaneous application of an electromagnetic high-frequency field perpendicular to the axis of the basic magnetic field, and in response to periodical changing of the electromagnetic field at a given frequency, the originally aligned paramagnetic nuclei are forced into a movement similar to that of a ``whipping top``. When the resonance frequency is shut off, the nuclei return to their former, aligned positions, inducing a weak signal in a coil. The series of signals generated by multiple repetition of this process of excitation of nuclei and their return to ...

1999-10-01

246

Rn3D: A finite element code for simulating gas flow and radon transport in variably saturated, nonisothermal porous media. User`s manual, Version 1.0  

Energy Technology Data Exchange (ETDEWEB)

This document is a user`s manual for the Rn3D finite element code. Rn3D was developed to simulate gas flow and radon transport in variably saturated, nonisothermal porous media. The Rn3D model is applicable to a wide range of problems involving radon transport in soil because it can simulate either steady-state or transient flow and transport in one-, two- or three-dimensions (including radially symmetric two-dimensional problems). The porous materials may be heterogeneous and anisotropic. This manual describes all pertinent mathematics related to the governing, boundary, and constitutive equations of the model, as well as the development of the finite element equations used in the code. Instructions are given for constructing Rn3D input files and executing the code, as well as a description of all output files generated ...

1994-01-01

247

A 3-D hydrodynamic dispersion model for modeling tracer transport in Geothermal Reservoirs  

International Nuclear Information System (INIS)

A 3-D hydrodynamic dispersion model for tracer transport is developed and implemented into the TOUGH2 EOS3 (T2R3D) module. The model formulation incorporates a full dispersion tensor, based on a 3-D velocity field with a 3-D, irregular grid in a heterogeneous geological system. Two different weighting schemes are proposed for spatial average of 3-D velocity fields and concentration gradients to evaluate the mass flux by dispersion and diffusion of a tracer or a radionuclide. This new module of the TOUGH2 code is designed to simulate processes of tracer/radionuclide transport using an irregular, 3-D integral finite difference grid in non-isothermal, three-dimensional, multiphase, porous/fractured subsurface systems. The numerical method ...

248

The Influence of Interleukin-4 on Ligament Healing  

UK PubMed Central (United Kingdom)

Despite a complex cascade of cellular events to reconstruct the damaged extracellular matrix, ligament healing results in a mechanically inferior scarred ligament. During normal healing, granulation...Full Text Available

2011-05-01

249

Korea, South  

Science.gov (United States)

Health Iran Iraq Landmines Middle East Muslim Outreach Narcotics Nonproliferation North Korea Pakistan Piracy Reconstruction and Stabilization Sudan Trafficking in Persons War...

2011-10-09

250

Information-seeking behaviour and coping style of women opting for either implant or DIEP-flap breast reconstruction  

British Library Electronic Table of Contents (United Kingdom)

Background: High satisfaction rates have been reported after autologous breast reconstruction. Yet, most mastectomy patients receive implant reconstructions (ImBR). Independent and active decision makers have shown mainly to choose for autologous reconstructions, such as the Deep inferior epigastric perforator (DIEP) flap (DiepBR). To further explore the decision making to opt for either ImBR or DiepBR, we investigated patient knowledge, informational resources used, effect of plastic surgeons' advice, coping style and personal independence. Methods: A total of 153 women, who were planned for DiepBR or ImBR preoperatively, completed a study-specific and standardised validated psychological questionnaire. Analyses were aimed at information-seeking behaviour, personal independence and coping...

2011-01-01

251

Exploratory Temperature and Precipitation Reconstructions from the Qinling Mountains, North-Central China  

Science.gov (United States)

... to the north of the Qinling, through mixed deciduous broad-leaved forest at lower mountain elevations, and conifer forest at ... ...

252

Estimation of the parameter covariance matrix for aone-compartment cardiac perfusion model estimated from a dynamic sequencereconstructed using map iterative reconstruction algorithms  

Energy Technology Data Exchange (ETDEWEB)

In dynamic cardiac SPECT estimates of kinetic parameters ofa one-compartment perfusion model are usually obtained in a two stepprocess: 1) first a MAP iterative algorithm, which properly models thePoisson statistics and the physics of the data acquisition, reconstructsa sequence of dynamic reconstructions, 2) then kinetic parameters areestimated from time activity curves generated from the dynamicreconstructions. This paper provides a method for calculating thecovariance matrix of the kinetic parameters, which are determined usingweighted least squares fitting that incorporates the estimated varianceand covariance of the dynamic reconstructions. For each transaxial slicesets of sequential tomographic projections are reconstructed into asequence of transaxial reconstructions usingfor each reconstruction inthe time sequence an iterative MAP reconstruction to ...

2004-01-01

253

Breast Cancer Treatment  

Medline Plus

... mammography or on ultrasound but not found on physical examination, we consider them non-palpable or not ... lot of this. We send every patient for physical therapy, no matter what type of reconstruction we ...

254

Afghanistan: Post-Taliban Governance, Security, and US ...  

Science.gov (United States)

... World Bank-run Afghanistan Reconstruction Trust Fund. ... No funds for Afghanistan have been held up ... Tehrik-e-Taliban Pakistan, TTP) is primarily ...

2010-10-19

255

Surface-loss power calculations for the LANSCE DTL  

Energy Technology Data Exchange (ETDEWEB)

The surface losses in the drift-tube linac (DTL) tanks 3 and 4 of the LANSCE linear accelerator are calculated using 3-D electromagnetic modeling with the CST MicroWave Studio (MWS). The results are used to provide more realistic power estimates for the 201.25MHz RF upgrade design within the LANSCE-R project. We compared 3-D MWS results with those from traditional 2-D Superfish computations for DTL cells and their simplified models and found differences on the level of a few percent. The differences are traced to a 3-D effect consisting in a redistribution of the surface currents on the drift tubes (DT) produced by the DT stem. The dependence of MWS results on the mesh size used in computations is also discussed.

2008-01-01

256

First trimester measurements of nasal bone length using three-dimensional ultrasound  

British Library Electronic Table of Contents (United Kingdom)

Objectives To investigate the feasibility and reproducibility of measurements of nasal bone length using a three-dimensional (3D) ultrasound in the first trimester. Methods In a prospective study, 118 consecutive pregnant women attending for Down syndrome screening at 11-13 + 6 weeks were recruited. They had successful fetal nasal bone measurement by two-dimensional (2D) ultrasound by four operators. Three-dimensional volumes were recorded in the mid-sagittal plane of fetal profile by the fifth operator and examined using multiplanar techniques. Another independent investigator randomly compared his measurements with one of the four operators. Results In the subsequent 3D examination, the nasal bone length could be examined in 94 cases (79.7%). The mean difference between the 2D and 3D mea...

2009-01-01

257

3D modelling as a support to thermal-hydraulic safety analyses with standard codes  

Energy Technology Data Exchange (ETDEWEB)

A three-dimensional (3D) thermal-hydraulic model and a numerical procedure for the simulation and analysis of a steady-state, as well as transient operation of nuclear power plant components are presented. A two-fluid approach is applied to modelling of two-phase flow. Thermal-hydraulics of a horizontal steam generator in the WWER 1000 nuclear power plant has been simulated at the full load, steady-state operation. A comparison of the numerical results with data measured at the NPP Novovoronjezh shows good agreement. 3D numerical results can be used in plant design or retrofitting, in nuclear power plant operation and safety analysis and as improvement of existing one-dimensional thermal-hydraulics models of the horizontal steam generator which are assessed by system codes used for the nuclear power plant safety analyses. (author)

1999-07-01

258

3D modelling as a support to thermal-hydraulic safety analyses with standard codes  

International Nuclear Information System (INIS)

A three-dimensional (3D) thermal-hydraulic model and a numerical procedure for the simulation and analysis of a steady-state, as well as transient operation of nuclear power plant components are presented. A two-fluid approach is applied to modelling of two-phase flow. Thermal-hydraulics of a horizontal steam generator in the WWER 1000 nuclear power plant has been simulated at the full load, steady-state operation. A comparison of the numerical results with data measured at the NPP Novovoronjezh shows good agreement. 3D numerical results can be used in plant design or retrofitting, in nuclear power plant operation and safety analysis and as improvement of existing one-dimensional thermal-hydraulics models of the horizontal steam generator which are assessed by system codes used for the nuclear power plant safety analyses. (author)

1999-04-19

259

3D model for a secondary facultative pond  

British Library Electronic Table of Contents (United Kingdom)

This paper describes a comprehensive model of wastewater treatment in secondary facultative ponds, which combines 3D hydrodynamics with a mechanistic water quality model. The hydrodynamics are based on the Navier-Stokes equation for incompressible fluids under shallow water and Boussinesq assumptions capturing the flow dynamics along length, breadth and depth of the pond. The water quality sub model is based on the Activated Sludge Model (ASM) concept, describing COD and nutrient removal as function of bacterial growth following Monod kinetics, except for Escherichia coli removal, which was modelled as first order decay. The model was implemented in the Delft3D software and was used to evaluate the effect of wind and the addition of baffles on the water flow pattern, temperature profiles i...

2011-01-01

260

[Retrieval of spectral characteristics of hyperspectral sensor and retrieval of reflectance spectra].  

Science.gov (United States)

On-orbit spectral calibration of hyperspectral imaging data is a key step for quantitatively analyzing them. Like the atmospheric correction, accurate spectral calibration is very necessary for improved studies of land or ocean surface properties. Based on the previous literatures, a new method which coupled an optimization algorithm was developed to simultaneously retrieve the central wavelength and the full width at half maximum (FWHM) of the hyperspectral sensor without needing the in situ reflectance spectra. Firstly, the Hyperion data set simulated using MODTRAN4 with the Hyperion spectral specification was used to test the new method, and the results indicated that the maximum error was less than 0.1 and 0.7 nm for central wavelength and FWHM respectively when the spectral shift is 5 nm. Then the algorithm was applied to the Hyperion data acquired on May 20, 2008 over Heihe River Basin and it was iteratively performed for each detector of the two ...

2010-10-01

261

Neutron-computer tomography using real-time neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

A real-time neutron radiography facility was constructed including the capability of neutron tomography. The neutron beam was measured for total neutron flux ((1.0 +/- 0.2) x 10/sup 11/ m/(m/sup 2/-sec)), gold cadmium ratio (52 +/- 3) and effective neutron temperature (83/sup 0/C +/- 8/sup 0/C). The angular divergence or nonparallelism of the neutron beam was measured to be 2.3/sup 0/ +/- 0.1/sup 0/ thereby providing a means of quantifying the collimator effectiveness. The resolution capabilities of both static film and real-time neutron radiographs were quantified using a Fourier transform algorithm to calculate the modulation transfer function of both types of radiographs. The contrast sensitivity of both types of radiographs. The contrast sensitivity of both types of radiographs was measured as 3.1% for film and 4.0% for real-time radiographs. Two tomography algorithms, the simultaneous iterative reconstruction technique (SIRT) and the convolution method, were ...

1986-01-01

262

Neutron-computer tomography using real-time neutron radiography  

International Nuclear Information System (INIS)

A real-time neutron radiography facility was constructed including the capability of neutron tomography. The neutron beam was measured for total neutron flux ((1.0 +/- 0.2) x 10"1"1 m/(m"2-sec)), gold cadmium ratio (52 +/- 3) and effective neutron temperature (83"0C +/- 8"0C). The angular divergence or nonparallelism of the neutron beam was measured to be 2.3"0 +/- 0.1"0 thereby providing a means of quantifying the collimator effectiveness. The resolution capabilities of both static film and real-time neutron radiographs were quantified using a Fourier transform algorithm to calculate the modulation transfer function of both types of radiographs. The contrast sensitivity of both types of radiographs. The contrast sensitivity of both types of radiographs was measured as 3.1% for film and 4.0% for real-time radiographs. Two tomography algorithms, the simultaneous iterative reconstruction technique (SIRT) and the convolution method, were programmed on an Intellect 100 ...

1986-01-01

263

Lacrimal gland masses on CT and MRI: a report of four cases; Raumforderungen der Traenendruese in CT und MRT am Beispiel von vier Faellen  

Energy Technology Data Exchange (ETDEWEB)

In an extended case report, we discuss four cases with masses in the lacrimal fossa representing the most important entities in this region (lymphoma, pleomorphadenoma, inflammatory pseudotumor, and malignant epithelial tumor). The different indications for CT and MRI are explained. For the differential diagnosis of lacrimal gland lesions, the following imaging parameters are important: The shape of the lacrimal gland, the inner structure, the degree of contrast enhancement, and the surrounding bony structures. In the evaluation of the expansion of lacrimal gland lesions, CT in thin slices with multiplanar reconstructions is equal to MRI. However, the contrast-enhancement of lacrimal glands is better evaluated with MRI than with CT. The bony structures are better visualized on CT than on MRI. (orig.) [Deutsch] In einem erweiterten Fallbericht wird ueber die vier grossen Entitaeten bei Traenendruesenraumforderungen berichtet (Lymphom, ...

1995-11-01

264

An iterative filtered backprojection inverse treatment planning algorithm for tomotherapy  

International Nuclear Information System (INIS)

Purpose: An inverse treatment planning algorithm for tomotherapy is described. Methods and Materials: The algorithm iteratively computes a set of nonnegative beam intensity profiles that minimizes the least-squares residual dose defined in the target and selected normal tissue regions of interest. At each iteration the residual dose distribution is transformed into a set of residual beam profiles using an inversion method derived from filtered backprojection image reconstruction theory. These 'residual' profiles are used to correct the current beam profile estimates resulting in new profile estimates. Adaptive filtering is incorporated into the inversion model so that the gross structure of the dose distribution is optimized during initial iterations of the algorithm, and the fine structure corresponding to edges is obtained at later iterations. A three dimensional, kernel based, convolution/superposition dose model is used to compute dose ...

1995-07-15

265

Aortic non communicating dissections. A study with helical CT  

International Nuclear Information System (INIS)

The evaluate the signs of aortic intramural hematoma with helical CT and the diagnostic role of this technique in patients with this condition. It was reviewed the CT findings of 396 patients submitted to emergency examinations for suspected aortic dissection from 1995 to 1999. Only 18 patients (6 women and 12 men) had CT signs of aortic intramural hematoma. Helical CT studies were carried out with the following parameters: slice thickness 10 mm, reconstruction index 10, feed 1.5 mm, conventional algorithm with minimum values of 130 kV and 125mA. All patients were examined with dynamic contrast-enhanced CT, before and after a power injection of 130 mL ionic contrast material. It was studied: hematoma localization and longitudinal extension; thickness and density of aortic wall; presence and location of intimal calcifications; integrity of intimal wall; hemo mediastinum and/or hemo thorax. Aortic wall thickening appeared as a high density crescent-shaped area at ...

2000-09-01

266

Optical Images Due to Lenses and Mirrors  

Science.gov (United States)

... Title : Optical Images Due to Lenses and Mirrors. ... Abstract : The properties of real and virtual images formed by lenses and mirrors are reviewed. ...

267
268

MAGNETIC RESONANCE IMAGING DEVICE  

J-STORE (Japan)

Full Text Available

2010-08-31

269

Test Cases - CFL3D - NASA  

Science.gov (United States)

Jun 10, 2011 ... Subsonic flow past a semi-infinite flat plate is modeled at Reynolds number 6 ..... data is taken from Cook, McDonald, and Firmin, AGARD-AR-138, 1979, p. ...... too large a time-averaged separation bubble behind the hump. ...

270

Statistical properties of nucleotide clusters in DNA sequences*  

UK PubMed Central (United Kingdom)

Using the complete genome of Plasmodium falciparum 3D7 which has 14 chromosomes as an example, we have examined the distribution functions for the amount of C or G and A or T consecutively...Full Text Available

2005-05-01

271

Robust principal axes determination for point-based shapes using least median of squares  

UK PubMed Central (United Kingdom)

A robust technique for determining the principal axes of a 3D shape represented by a point set, possibly with noise, is presented. We use techniques from robust statistics to guide the classical...Full Text Available

2009-04-01

272

Phase separation, pore structure, and properties of nanofibrous gelatin scaffolds  

UK PubMed Central (United Kingdom)

The development of three-dimensional (3D) biomimetic scaffolds which provide an optimal environment for cells adhesion, proliferation and differentiation, and guide new tissue formation has...Full Text Available

2009-09-01

273

Particle Swarm Optimization: An efficient method for tracing periodic orbits in 3D galactic potentials  

CERN Document Server

We propose the Particle Swarm Optimization (PSO) as an alternative method for locating periodic orbits in a three--dimensional (3D) model of barred galaxies. We develop an appropriate scheme that transforms the problem of finding periodic orbits into the problem of detecting global minimizers of a function, which is defined on the Poincar\\'{e} Surface of Section (PSS) of the Hamiltonian system. By combining the PSO method with deflection techniques, we succeeded in tracing systematically several periodic orbits of the system. The method succeeded in tracing the initial conditions of periodic orbits in cases where Newton iterative techniques had difficulties. In particular, we found families of 2D and 3D periodic orbits associated with the inner 8:1 to 12:1 resonances, between the radial 4:1 and corotation resonances of our 3D Ferrers bar model. The main ...

2005-01-01

274

PRISM 3D: Global Warming Analysis  

Science.gov (United States)

Estimates of global warming during the mid-Piacenzian Age of the Pliocene Epoch suggest temperatures were 2 degrees C greater than today. ... million years approaches this level of warming. PRISM/Global Warmin...

275

Natural Gaits of the Non-Pathological Flat Foot and High-Arched Foot  

UK PubMed Central (United Kingdom)

There has been a controversy as to whether or not the non-pathological flat foot and high-arched foot have an effect on human walking activities. The 3D foot scanning system was employed to obtain static...Full Text Available

276

Modelling the masticatory biomechanics of a pig  

UK PubMed Central (United Kingdom)

The relationships between muscle tensions, jaw motions, bite and joint forces, and craniofacial morphology are not fully understood. Three-dimensional (3-D) computer models are able to combine anatomical...Full Text Available

2002-11-01

277

Metacad programmer's guide  

Energy Technology Data Exchange (ETDEWEB)

Metacad is a collection of routines which creates a randomly accessible data structure from Applicon's APPLE-3D data format and supplies a logical method for manipulation of the data structure by a CAD application program.

1983-05-01

278

Lockheed WP-3D Orion  

Science.gov (United States)

Approximately 62,000 lbs Fuel Load: 58,000 lbs. Type Fuel: JP4, JP5, JP8, JET A, JET A-1, JET B Standard Fuel Burn: 4500 - 6000 lbs/hr depending on altitude and airspeed Maximum...

2011-08-17

279

Heat transfer augmentation in 3D internally finned and microfinned helical tube  

Energy Technology Data Exchange (ETDEWEB)

Experiments are performed to investigate the single-phase flow and flow-boiling heat transfer augmentation in 3D internally finned and micro-finned helical tubes. The tests for single-phase flow heat transfer augmentation are carried out in helical tubes with a curvature of 0.0663 and a length of 1.15 m, and the examined range of the Reynolds number varies from 1000 to 8500. Within the applied range of Reynolds number, compared with the smooth helical tube, the average heat transfer augmentation ratio for the two finned tubes is 71% and 103%, but associated with a flow resistance increase of 90% and 140%, respectively. A higher fin height gives a higher heat transfer rate and a larger friction flow resistance. The tests for flow-boiling heat transfer are carried out in 3D internally micro-finned helical tube with a curvature of 0.0605 and a length of 0.668 m. Compared with that in the smooth helical ...

2005-05-01

280

Evaluation of tilted cone-beam CT orbits in the development of a dedicated hybrid mammotomograph  

UK PubMed Central (United Kingdom)

A compact dedicated 3D breast SPECT-CT (mammotomography) system is currently under development. In its initial prototype, the cone-beam CT sub-system is restricted to a fixed-tilt circular rotation...Full Text Available

2009-06-21

281

Electrospray deposition and direct patterning of polylactic acid nanofibrous microcapsules for tissue engineering.  

Science.gov (United States)

Electrospun nanofibers composed of biodegradable polymers are attractive candidates for cell culture scaffolds in tissue engineering. Their fine-meshed structures, resembling natural extracellular matrices, effectively interact with cell surfaces and promote cell proliferation. The application of electrospinning, however, is limited to two-dimensional (2D) or single tube-like scaffolds, and the fabrication of arbitrary three-dimensional (3D) scaffolds from electrospun nanofibers is still very difficult due to the fibers' continuous and entangled form. To address this issue, in this paper, we describe the use of phase-separation-assisted electrospray and electrostatic focusing to perform continuous direct 3D patterning of nanofibrous microcapsules of biodegradable polylactic acid (PLA). These microcapsules exhibit fiber-particle duality because they are composed of nanofibers suitable for cell attachment ...

2011-09-01

282

Computational study of jet interaction flow field with and without incidence  

International Nuclear Information System (INIS)

The objective was to study the interaction of a side jet with the incoming supersonic flow and hypersonic flow. Qualitatively same Cp trends have been obtained as found experimentally. Also in aerodynamic coefficients side jet interaction results in additional pitching moment which is because of the high pressure region in upstream of the jet and a low pressure region in the downstream of the jet. Also jet interaction results in the rise in the lift coefficient. Whereas in the incidence case, simulation has been performed for the hypersonic flows over a biconic body with supersonic lateral jet at Mach 9.7 and incidence of 0"o to incidence of -12"o and 12"o. The results obtained were compared with the experimental and CFD code CFL3D results. PAK-3D over predicts the surface pressure as compared to the CFL3D and experimental results, whereas the qualitative trends ...

2004-05-09

283

Characterization of 3D thermal neutron semiconductor detectors  

International Nuclear Information System (INIS)

Neutron semiconductor detectors for neutron counting and neutron radiography have an increasing importance. Simple silicon neutron detectors are combination of a planar diode with a layer of an appropriate neutron converter such as 6LiF. These devices have limited detection efficiency of not more than 5%. The detection efficiency can be increased by creating a 3D microstructure of dips, trenches or pores in the detector and filling it with a neutron converter. The first results related to the development of such devices are presented. Silicon detectors were fabricated with pyramidal dips on the surface covered with 6LiF and then irradiated by thermal neutrons. Pulse height spectra of the energy deposited in the sensitive volume were compared with simulations. The detection efficiency of these devices was about 6.3%. Samples with different column sizes were fabricated to study the electrical properties of ...

2007-06-11

284

A self-oscillating biophysical computer model of the elongated vocal fold  

UK PubMed Central (United Kingdom)

A new 3D model is developed to simulate the self-oscillation of the elongated vocal folds. This model allows for large deformation and longitudinal displacement. The displacement boundary condition...Full Text Available

2008-01-01

285

3D simulations of microstructure and comparison with experimental microstructure coming from OIM analysis  

International Nuclear Information System (INIS)

This paper presents a new methodology to create realistic 3D microstructures of polycrystals. The virtual microstructures are based on statistical data describing the morphological and crystallographic textures of a sample, obtained from an EBSD analysis. In addition, the methodology can reproduce the observed surface on top of the simulated microstructure. This feature allows finite element calculations on these virtual aggregates to be compared to experimental results of mechanical tests. Such a comparison leads to the identification of the mechanical parameters of constitutive laws, such as critical resolved shear stress and strain hardening, using an optimization algorithm. Two materials were simulated in this study: TiAl and grade 702 zirconium. The first one presents twins inside the microstructure and the second one has an anisotropic texture. Based on 2D simulations, the important parameters necessary to describe a microstructure were ...

286

3D Hepatic Cultures Simultaneously Maintain Primary Hepatocyte and Liver Sinusoidal Endothelial Cell Phenotypes  

UK PubMed Central (United Kingdom)

Developing in vitro engineered hepatic tissues that exhibit stable phenotype is a major challenge in the field of hepatic tissue engineering. However, the rapid dedifferentiation of...Full Text Available

287

Clinical implementation of a convolution based algorithm for 3D treatment planning  

International Nuclear Information System (INIS)

Purpose/Objective: With the advent of computed tomography and magnetic resonance imaging, the three dimensional representation of the patient anatomy has become an invaluable resource for better diagnosis and delineation of the target volume and sensitive structures in radiation therapy. Although the therapeutic linear accelerator industry has made available highly sophisticated equipment, the aggressiveness in dose prescription and delivery has to be complimented by accurate dose computation methods. We have adopted a convolution/superposition algorithm for the calculation of absolute dose that fully accounts for the external shape and internal structure of the patient for photon treatment radiotherapy. In this paper, we will discuss the principles of the convolution algorithm and we will show how the computed dose compares to clinically relevant treatment techniques. Materials and Methods: A computer controlled data acquisition system and a water tank where used ...

288

The relative X-ray intensity Ksub(#alpha#)/Ksub(#beta#) of 3d elements by photoionization and electron capture  

International Nuclear Information System (INIS)

The measurement of K(alpha)/K(beta) X-ray intensity ratio indicates the excitation process and the chemical state of the atom examined. Theoretical considerations on the origin of this property are presented. The difference of these ratios following photoionization and electron capture are calculated by a computer code generating transition matrix elements. The theoretical assumptions involved in the codes are tested by comparing the experimental and calculated data concerning 3d transition element atoms. (D.Gy.).

1981-03-19

289

PARALLEL 3-D SPACE CHARGE CALCULATIONS IN THE UNIFIED ACCELERATOR LIBRARY.  

Energy Technology Data Exchange (ETDEWEB)

The paper presents the integration of the SIMBAD space charge module in the UAL framework. SIMBAD is a Particle-in-Cell (PIC) code. Its 3-D Parallel approach features an optimized load balancing scheme based on a genetic algorithm. The UAL framework enhances the SIMBAD standalone version with the interactive ROOT-based analysis environment and an open catalog of accelerator algorithms. The composite package addresses complex high intensity beam dynamics and has been developed as part of the FAIR SIS 100 project.

2006-06-26

290

Development of a motion analysis system using acceleration sensors for tennis and its evaluations  

British Library Electronic Table of Contents (United Kingdom)

The term biological motion is often used by researchers studying the patterns of movement generated by living forms and in sports. We studied a pattern recognition system of motion in sport using biological motion data. Biological motion data are acquired using a 3D motion capture system. However, 3D motion capture systems are very expensive. In this article, a biological motion capture system was built using acceleration sensors. Our proposed system uses the technique of Gaussian fitting and regression analysis. We tested our proposed system in pattern recognition of outdoor tennis and its evaluations.

2011-01-01

291

Comparison of EH with SW-Xsub(alpha) calculations. Electronic structure of 3d, 4d, and 5d metal atom clusters  

Energy Technology Data Exchange (ETDEWEB)

The electronic structure of octahedral metal atom clusters Me/sub 6/ of 3d, 4d, and 5d transition metal atoms (V, Cr; Nb, Mo; Ta, W) has been calculated applying two different quantum-chemical approximation methods (Extended Hueckel (EH) method; SW-Xsub(alpha) method). Equilibrium structures, energy level schemes, Fermi energies and band widths as well as densities of states of clusters are discussed in detail.

1981-01-01

292

Anticonvulsant properties of selected pyrrolo[2,3-d]pyrimidine-2,4-diones and intermediates.  

Science.gov (United States)

A series of pyrrolo[2,3-d]pyrimidine-2,4-diones and intermediates was tested for anticonvulsant activity in mice. Eleven of the 15 compounds possessed anticonvulsant activity against pentylenetetrazol-induced convulsions. One compound afforded more anticonvulsant protection against pentylenetetrazol than did trimethadione (67 and 50%, respectively). A suspension of this compound was found to be as effective as a solution in producing anticonvulsant activity. The results suggest that the nitrile analogs were more potent compared to the carbamyl analog due to higher lipid solubility. PMID:7373552

1980-04-01

293

New approach to the design of LMFBR liners  

Energy Technology Data Exchange (ETDEWEB)

The reconstruction of steel lining of the FFTF reactor building is described. The cold part of the lining has a simple structure and represents a steel sheet of 6.35 mm thickness welded to I-shaped imbedded in concrete, the hot part is meant for resisting the hot sodium contacting with it. The reconstruction has been reduced to the substitution of usual lining, the sheets of which are fixed in such a way that dangerous strains in metal arising at evaporation are excluded by the new structure admitting sheet deformation.

1981-01-01

294

Helical CT defecography; La defecografia con Tomografia Computerizzata spirale  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this work is to investigate the possible role of Helical CT defecography in pelvic floor disorders by comparing the results of the investigations with those of conventional defecography. The series analyzed consisted of 90 patients, namely 62 women and 28 men, ranging in age 24-82 years. They were all submitted to conventional defecography, and 18 questionable cases were also studied with Helical CT defecography. The conventional examination was performed during the 4 standard phases of resting, squeezing, Valsalva and straining; it is used a remote-control unit. The parameters for Helical CT defecography were: 5 mm beam collimation, pitch 2, 120 KV, 250 m As and 18-20 degrees gantry inclination to acquire coronal images of the pelvic floor. The rectal ampulla was distended with a bolus of 300 mL nonionic iodinated contrast agent (dilution: 3g/cc). The patient wore a napkin and was seated on the table, except for those who could not hold the position ...

1999-11-01

295

Staging of multiple myeloma with MRI: comparison to MSCT and conventional radiography; Staging des multiplen Myeloms mit der MRT: Vergleich zur MSCT und zur konventionellen Roentgendiagnostik  

Energy Technology Data Exchange (ETDEWEB)

The staging of patients with multiple myeloma demands sensitive imaging methods for the assessment of the skeletal system. MRI allows for direct visualization of the bone marrow which exhibits five different infiltration patterns in multiple myeloma: 1. normal appearance of the bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. ''salt and pepper'' pattern with inhomogeneous bone marrow signals due to multiple fat islands. The combination of T1w-SE and STIR sequences is best suited for detecting all infiltration patterns and for the differential diagnoses e. g. hemangiomas. With parallel imaging in MRI, acquisition times can be markedly reduced and whole-body screening of the bone marrow can be achieved within 30 min. MRI is superior to radiography for the detection of focal as well as diffuse infiltration. Multidetector computed tomography ...

2004-09-01

298

Java Image I/O for VICAR, PDS, and ISIS  

Science.gov (United States)

This library, written in Java, supports input and output of images and metadata (labels) in the

2011-01-01

299

A non-local approach for image super-resolution using intermodality priors ?  

UK PubMed Central (United Kingdom)

Image enhancement is of great importance in medical imaging where image resolution remains a crucial point in many image analysis algorithms. In this paper, we investigate brain hallucination...Full Text Available

2010-08-01

300

NORTH HILL CREEK 3-D SEISMIC EXPLORATION PROJECT  

Energy Technology Data Exchange (ETDEWEB)

Wind River Resources Corporation (WRRC) received a DOE grant in support of its proposal to acquire, process and interpret fifteen square miles of high-quality 3-D seismic data on non-allotted trust lands of the Uintah and Ouray (Ute) Indian Reservation, northeastern Utah, in 2000. Subsequent to receiving notice that its proposal would be funded, WRRC was able to add ten square miles of adjacent state and federal mineral acreage underlying tribal surface lands by arrangement with the operator of the Flat Rock Field. The twenty-five square mile 3-D seismic survey was conducted during the fall of 2000. The data were processed through the winter of 2000-2001, and initial interpretation took place during the spring of 2001. The initial interpretation identified multiple attractive drilling prospects, two of which were staked and permitted during the summer of 2001. The two initial wells were drilled in ...

2004-05-06

301

Particle Flow at CMS and the ILC  

CERN Document Server

This thesis describes hadron reconstruction at the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) at CERN, Geneva. The focus is on the particle flow reconstruction of these objects. This thesis revisits the subject of the CMS calorimeters' non-linear response to hadrons. Data from testbeam experiments conducted in 2006 & 2007 is compared with simulations and substantial differences are found. A particle flow calibration to correct the energy response of the testbeam data is evaluated. The reconstructed jet response is found to change by ~ 5% when a data-driven calibration is used in place of the calibration derived from simulation. Collision data taken at the early stage of CMS' commissioning is also presented. The hadron response in data is determined to be compatible with testbeam results presented in this thesis. This thesis also details the use of neural networks to improve the energy ...

2010-01-01

302

Combined bony closure of oroantral fistula and sinus lift with mandibular bone grafts for subsequent dental implant placement  

British Library Electronic Table of Contents (United Kingdom)

Sinus lifting and reconstruction of localized alveolar defects are often required after closure of a large oroantral fistula (OAF) to allow for subsequent implant installation. This study describes a combined surgical technique that involves sinus lifting, bony closure, and reconstruction of the alveolar defect at the site of an OAF. The sinus membrane was reconstructed as a continuous layer by combining the residual sinus membrane with a rotated part of oral mucosa around the OAF. Autogenous bone from the chin and/or ramus was grafted into the prepared sinus space and alveolar defect, and the graft was covered by a buccal advancement flap. This technique was used to treat 8 patients who had large OAFs in the posterior maxillary region. The treatment was successful in all cases, and the te...

2011-01-01

303

A tomography system at the thermal neutron column of the ENEA Casaccia TRIGA reactor  

Energy Technology Data Exchange (ETDEWEB)

The developed system is intended for use at a collimated thermal neutron beam with a flux of about 10{sup 6} n/cm{sup 2} s. The system works with a cooled CCD array (192 x 165 pixels) and an intensifier for light from a NE426 scintillator with traditional optical coupling. A fine mechanical regulation system allows an accurate positioning of the tomographer, also ensuring the alignment of the CCD array with the rotation and translation axes. The acquisition of 200 projections is carried out in about 30 min with a reconstruction time (40 min max) depending on the reconstruction-matrix order. Radiography and tomography of significant objects are illustrated. The reconstruction algorithm, including spatial and temporal inhomogeneity corrections and filters, was tested with good results for projections up to 512 x 512 pixels. (orig.)

2002-07-01

304

A tomography system at the thermal neutron column of the ENEA Casaccia TRIGA reactor  

International Nuclear Information System (INIS)

The developed system is intended for use at a collimated thermal neutron beam with a flux of about 10"6 n/cm"2 s. The system works with a cooled CCD array (192 x 165 pixels) and an intensifier for light from a NE426 scintillator with traditional optical coupling. A fine mechanical regulation system allows an accurate positioning of the tomographer, also ensuring the alignment of the CCD array with the rotation and translation axes. The acquisition of 200 projections is carried out in about 30 min with a reconstruction time (40 min max) depending on the reconstruction-matrix order. Radiography and tomography of significant objects are illustrated. The reconstruction algorithm, including spatial and temporal inhomogeneity corrections and filters, was tested with good results for projections up to 512 x 512 pixels. (orig.)

305

A search for resonant Z pair production  

Energy Technology Data Exchange (ETDEWEB)

I describe a search for anomalous production of Z pairs through a new massive resonance X in 2.5-2.9 fb{sup -1} of p{bar p} collisions at {radical}s = 1.96 TeV using the CDFII Detector at the Fermilab Tevatron. I reconstruct Z pairs through their decays to electrons, muons, and quarks. To achieve perhaps the most efficient lepton reconstruction ever used at CDF, I apply a thorough understanding of the detector and new reconstruction software heavily revised for this purpose. In particular, I have designed and employ new general-purpose algorithms for tracking at large {eta} in order to increase muon acceptance. Upon analyzing the unblinded signal samples, I observe no X {yields} ZZ candidates and set upper limits on the production cross section using a Kaluza-Klein graviton-like acceptance.

2008-12-01

306

Valence electronic structure of Ti, Cr, Fe and Co in some alloys from K{beta}-to-K{alpha} X-ray intensity ratio studies  

Energy Technology Data Exchange (ETDEWEB)

K{beta}-to-K{alpha} X-ray intensity ratios of Ti, Cr, Fe and Co in pure metals and in Cr{sub 0.26}Fe{sub 0.74}, Cr{sub 0.80}Co{sub 0.20} and Ti{sub 0.80}Cr{sub 0.20} alloys have been measured following excitation by 59.54 keV {gamma}-rays from a 7400 MBq (200 mCi) {sup 241}Am point-source. The valence electronic structure of Ti, Cr, Fe and Co in the samples have been evaluated by the comparison of the measured K{beta}-to-K{alpha} intensity ratios with the results of multiconfiguration Dirac-Fock calculations performed for various electronic configurations of these metals. The 3d-electron populations obtained for pure metallic Ti, Cr, Fe and Co agree well with the results of band structure calculations of Papaconstantopoulos (Handbook of band structure of elemental solids, Plenum Press, New York, 1986). Our analysis indicates significant increase of 3d-electron population of Ti, Cr and Fe in the alloys ...

2002-10-01

307

Valence electronic structure of Ti, Cr, Fe and Co in some alloys from K#beta#-to-K#alpha# X-ray intensity ratio studies  

International Nuclear Information System (INIS)

K#beta#-to-K#alpha# X-ray intensity ratios of Ti, Cr, Fe and Co in pure metals and in Cr_0_._2_6Fe_0_._7_4, Cr_0_._8_0Co_0_._2_0 and Ti_0_._8_0Cr_0_._2_0 alloys have been measured following excitation by 59.54 keV #gamma#-rays from a 7400 MBq (200 mCi) "2"4"1Am point-source. The valence electronic structure of Ti, Cr, Fe and Co in the samples have been evaluated by the comparison of the measured K#beta#-to-K#alpha# intensity ratios with the results of multiconfiguration Dirac-Fock calculations performed for various electronic configurations of these metals. The 3d-electron populations obtained for pure metallic Ti, Cr, Fe and Co agree well with the results of band structure calculations of Papaconstantopoulos (Handbook of band structure of elemental solids, Plenum Press, New York, 1986). Our analysis indicates significant increase of 3d-electron population of Ti, Cr and Fe in the alloys with respect to ...

2002-10-01

308

Electron-ion recombination of neutral iron  

Energy Technology Data Exchange (ETDEWEB)

The total and state-specific electron-ion recombination rate coefficients are obtained for FeI. The calculations are carried out using a new ab initio method that incorporates both the radiative and the dielectronic recombination processes in an unified and self-consistent manner. The computations employ the close coupling approximation and the R-matrix method from atomic collision theory. A 52 state close coupling eigenfunction expansion dominated by the states of the ground 3d{sup 6}4s and excited 3d{sup 7}, 3d{sup 6}4p, 3d{sup 5}4s{sup 2}, and 3d{sup 5}4s4p configurations of FeII are used in the present calculations. The important electron correlation and radiation damping effects are included via explicit coupling of autoionization and radiative channels. This is the first ...

1997-04-01

309

Decay of "1"7"7T_a composite nucleus. Comparison of excitation functions for the reaction residues occurring in "1"2C + "1"6"5H_0 and "1"4N + "1"6"3D_y reactions  

International Nuclear Information System (INIS)

The experimental has been performed with a view to studying complete and incomplete fusion in "1"4N + "1"6"3D_y system below 7 MeV/nucleon. The excitation functions for several reactions have been measured using the activation technique and compared with the theoretical predictions based on statistical models. The codes ALICE-91 and CASCADE used earlier for the analysis of excitation functions in case of "1"2C + "1"6"5H_0 system have been used here also with the same set of input parameters. It has been observed that the theoretical calculations do not match with the experimental excitation functions well but the overall shape of the excitation function is reproduced satisfactorily. The composite nucleus ("1"7"7T_a) formed in this ("1"4N + "1"6"3D_y) case is the same as the one formed in "1"2C + "1"6"5H_0 system studied earlier. Measured excitation functions for the same decay channels in the two cases ...

2002-10-01

310

3D Atlas vertical plate oil transmission line field calculations. Final report  

Energy Technology Data Exchange (ETDEWEB)

Because of questions regarding current density and inductance estimates of the Atlas oil transmission line in the region where the vertical plates connect to the disk line, calculations using the 3D FE program Flux3d were initiated. Flux3d inductance values are nearly that estimated by D. Scudder. Calculations for three base designs of E. Ballard and D. Pierce were completed where several variations for each base design were used to determine the important parameters affecting inductance and to check inductance consistency. Flux3d showed for the first base design a very high current density of 36MA/m at the connection between the vertical and horizontal ground plates resulting in a magnetic pressure of 120 kpsi. The second base design modified this connection to reduce the current density to 20MA/m and 36 kpsi and for ...

1997-09-18

311

3-D depth migration: various methods and how they perform on real data  

Energy Technology Data Exchange (ETDEWEB)

3-D depth migration is one of the most active areas of research and development and it has been approached from different angles. An accurate algorithm which works in the space-frequency domain was introduced by Blacquiere et al. (1989). Unfortunately, it is computationally very expensive and not suitable for solving real-life 3-D migration problems. This led to the development of an alternative scheme (hale, 1990) which sacrifices some accuracy but is much more efficient. It is commonly referred to as the Hale-McClellan method. An alternative procedure known as reverse-time migration works in the space-time domain. It is based on the full wave equation and yields by far the most accurate results, but it requires extremely large computer resources. However, a series of new developments (Mufti et al, 1996) have made this algorithm a very practical tool even for migrating large exploration-scale ...

1997-07-01

312

Wiener Reconstruction of Large-Scale Structure from Peculiar Velocities  

CERN Document Server

We present an alternative, Bayesian method for large-scale reconstruction from observed peculiar velocity data. The method stresses a rigorous treatment of the random errors and it allows extrapolation into poorly sampled regions in real space or in k-space. A likelihood analysis is used to determine the fluctuation power spectrum, followed by a Wiener Filter (WF) analysis to obtain the minimum-variance mean fields of velocity and mass density. Constrained Realizations (CR) are then used to sample the statistical scatter about the WF mean field. The WF/CR method is applied as a demonstration to the Mark III data with 1200 km/s, 900 km/s, and 500 km/s resolutions. The main reconstructed structures are consistent with those extracted by the POTENT method. A comparison with the structures in the distribution of IRAS 1.2Jy galaxies yields a general agreement. The reconstructed velocity field is decomposed into its divergent and ...

1999-01-01

313

Sternal plate fixation for sternal wound reconstruction: initial experience (Retrospective study)  

UK PubMed Central (United Kingdom)

BackgroundMedian sternotomy infection and bony nonunion are two commonly described complications which occur in 0.4 - 5.1% of cardiac procedures. Although relatively infrequent,...Full Text Available

314

Reconstruction of the complete human cytomegalovirus genome in a BAC reveals RL13 to be a potent inhibitor of replication  

UK PubMed Central (United Kingdom)

Human cytomegalovirus (HCMV) in clinical material cannot replicate efficiently in vitro until it has adapted by mutation. Consequently, wild-type HCMV differ fundamentally from the passaged strains...Full Text Available

2010-09-01

315

Reconstruction of the activity of point sources for the accurate characterization of nuclear waste drums by segmented gamma scanning  

International Nuclear Information System (INIS)

This work improves the reliability and accuracy in the reconstruction of the total isotope activity content in heterogeneous nuclear waste drums containing point sources. The method is based on #chi#"2-fits of the angular dependent count rate distribution measured during a drum rotation in segmented gamma scanning. A new description of the analytical calculation of the angular count rate distribution is introduced based on a more precise model of the collimated detector. The new description is validated and compared to the old description using MCNP5 simulations of angular dependent count rate distributions of Co-60 and Cs-137 point sources. It is shown that the new model describes the angular dependent count rate distribution significantly more accurate compared to the old model. Hence, the reconstruction of the activity is more accurate and the errors are considerably reduced that lead to more reliable results. Furthermore, the results are ...

2011-06-01

316

Reconstructing Mammalian Phylogenies: A Detailed Comparison of the Cytochrome b and Cytochrome Oxidase Subunit I Mitochondrial Genes  

UK PubMed Central (United Kingdom)

The phylogeny and taxonomy of mammalian species were originally based upon shared or derived morphological characteristics. However, genetic analyses have more recently played an increasingly important...Full Text Available

317

Poland's anomaly. Natural history and long-term results of chest wall reconstruction in 33 patients.  

UK PubMed Central (United Kingdom)

Poland's anomaly is an uncommon congenital aberration of the chest wall characterized by absence of the pectoralis major muscle and other nearby musculoskeletal components. In this series, a wide spectrum...Full Text Available

1988-12-01

318

Patient-specific reconstructed anatomies and computer simulations are fundamental for selecting medical device treatment: application to a new percutaneous pulmonary valve  

UK PubMed Central (United Kingdom)

Nowadays, percutaneous pulmonary valve implantation is a successful alternative to surgery for patients requiring treatment of pulmonary valve dysfunction. However, owing to the wide variety of implantation...Full Text Available

2010-06-28

319

Major evolutionary transitions in ant agriculture  

UK PubMed Central (United Kingdom)

Agriculture is a specialized form of symbiosis that is known to have evolved in only four animal groups: humans, bark beetles, termites, and ants. Here, we reconstruct the major evolutionary transitions...Full Text Available

2008-04-08

320

In-vivo coronary flow profiling based on biplane angiograms: influence of geometric simplifications on the three-dimensional reconstruction and wall shear stress calculation  

UK PubMed Central (United Kingdom)

BackgroundClinical studies suggest that local wall shear stress (WSS) patterns modulate the site and the progression of atherosclerotic lesions. Computational fluid dynamics (CFD)...Full Text Available

321

Impact of Posterior Urethral Plate Repair on Continence Following Robot-Assisted Laparoscopic Radical Prostatectomy  

UK PubMed Central (United Kingdom)

PurposeThe objective of this study is to evaluate the continence rate following reconstruction of the posterior urethral plate in robot-assisted laparoscopic radical prostatectomy...Full Text Available

2010-05-01

322

Freeze-Dried Tendon Allografts as Tissue Engineering Scaffolds for Gdf5 Gene Delivery  

UK PubMed Central (United Kingdom)

Tendon reconstruction using grafts often results in adhesions that limit joint flexion. These adhesions are precipitated by inflammation, fibrosis, and paucity of tendon differentiation signals...Full Text Available

2008-03-01

323

Exchange algebra and the Drinfeld-Sokolov theorem  

International Nuclear Information System (INIS)

We analyse the relation between the exchange algebra and the separation of the chiralities in classical Toda field theory. We show that there exists a conformally covariant Bloch wave basis such that the two chiralities commute. In terms of this basis we then reconstruct the periodic and local solution of Toda field theory. (orig.).

1991-01-01

324

Estimating trace deposition time with circadian biomarkers: a prospective and versatile tool for crime scene reconstruction  

UK PubMed Central (United Kingdom)

Linking biological samples found at a crime scene with the actual crime event represents the most important aspect of forensic investigation, together with the identification of the sample donor. While...Full Text Available

2010-09-01

325

Divergent Regulation of Angiopoietin-1 and -2, Tie-2, and Thrombospondin-1 Expression by Estrogen in the Baboon Endometrium  

UK PubMed Central (United Kingdom)

SUMMARYEstrogen has an important role in the reconstruction of a new vascular network in the endometrium during each menstrual cycle; however, the underlying mechanisms...Full Text Available

2010-05-01

326

View larger image for ISS022-E-26137 - Earth Sciences and Image ...  

Science.gov (United States)

The Asarco-Mission complex (image left) is an active producer of copper and molybdenum (important in making steel and other metal alloys), ...

327

Digital processing to improve image quality in real-time neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction ...

1985-01-01

328

Digital processing to improve image quality in real-time neutron radiography  

International Nuclear Information System (INIS)

Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction ...

1985-01-01

329

Advances in Imaging of Vertebral and Spinal Cord Injury  

UK PubMed Central (United Kingdom)

Background/Objectives:Imaging technology is an important part of the diagnosis and management of spinal trauma. Indications and findings in post-traumatic imaging of the vertebral...Full Text Available

2010-04-01

330

3 - NASA Technical Report Server (NTRS)  

Science.gov (United States)

performs Gaussian pyramid operation on an image performs expand pyramid operation on an image mosaic two images using 'reduce' and 'expand' pyramid ...

331

Valence-electron configuration of Ti and Ni in TixNi1-x alloys from Kbeta-to-Kalpha X-ray intensity ratio studies.  

Science.gov (United States)

Kbeta-to-Kalpha X-ray intensity ratios of Ti and Ni have been measured in pure metals and in alloys of Ti(x)Ni(1-x) (x=0.7, 0.6, 0.5, 0.4 and 0.3) following excitation by 22.69 keV X-rays from a 10 mCi (109)Cd radioactive point source. The valence-electron configurations of these metals were determined by corporation of measured Kbeta-to-Kalpha X-ray intensity ratios with the results of multiconfiguration Dirac-Fock calculation for various valence-electron configurations. Valence-electron configurations of 3d-transition metals in alloys indicate significant differences with respect to the pure metals. Our analysis indicates that these differences arise from delocalization and/or charge transfer phenomena in alloys. Namely, the observed change of the valence-electron configurations of metals in alloys can be explained with the transfer of 3d electrons from one element to the other element and/or the ...

2010-01-28

332

Valence-electron configuration of Ti and Ni in TixNi1-x alloys from K?-to-K? X-ray intensity ratio studies  

International Nuclear Information System (INIS)

K?-to-K? X-ray intensity ratios of Ti and Ni have been measured in pure metals and in alloys of TixNi1-x (x=0.7, 0.6, 0.5, 0.4 and 0.3) following excitation by 22.69 keV X-rays from a 10 mCi 109Cd radioactive point source. The valence-electron configurations of these metals were determined by corporation of measured K?-to-K? X-ray intensity ratios with the results of multiconfiguration Dirac-Fock calculation for various valence-electron configurations. Valence-electron configurations of 3d-transition metals in alloys indicate significant differences with respect to the pure metals. Our analysis indicates that these differences arise from delocalization and/or charge transfer phenomena in alloys. Namely, the observed change of the valence-electron configurations of metals in alloys can be explained with the transfer of 3d electrons from one element to the other element and/or the rearrangement of ...

2010-06-01

333

Three-dimensional power system stabilizer  

Energy Technology Data Exchange (ETDEWEB)

Power system stabilizers (PSSs) are used to enhance damping of power system oscillations through excitation control of synchronous generator. The objective of the PSS is to generate a stabilizing signal, which produces a damping torque component on the generator shaft. Conventional PSSs are designed with the phase compensation technique in the frequency domain and include the lead-lag blocks whose parameters are determined according to a linearized power system model. The performance of conventional PSSs (CPSSs) depends upon the generator operating point and the system parameters, but a reasonable level of robustness can be achieved depending on the tuning method. This paper presents a new three-dimensional PSS (3D PSS), which uses rotor speed deviation, rotor acceleration and load angle deviation as input signals. The 3D PSS attempts to return the generator to the state-space origin, based on the ...

2010-07-15

334

Three-dimensional mise-a-la-masse modeling using horizontal well; Suihei kosei wo mochiita ryuden den`iho no sanjigen modeling  

Energy Technology Data Exchange (ETDEWEB)

The 3-D model program was developed to apply a mise-a-la-masse method to linear current sources with optional shapes. Mise-a-la-masse method is a bipolar mapping survey method using current sources installed in wells, and recently has been widely used for direct exploration of geothermal reservoirs. This method is also used for monitoring underground fluid as electrode arrangement of fluid flow tomography for surveying underground fluid (geothermal fluid, underground water, petroleum). In the geothermal reservoir exploration, the casing pipes of wells are used as linear current sources, and measured data are processed as those based on vertical current source. In the largely inclined well, the inclination of current sources should be considered. The 3-D modeling program was developed by difference calculus using the theoretical potential equation and apparent resistivity based on linear current sources ...

1996-10-01

335

Prediction of parallel NIKE3D performance on the KSR1 system  

Energy Technology Data Exchange (ETDEWEB)

Finite element method is one of the bases for numerical solutions to engineering problems. Complex engineering problems using finite element analysis typically imply excessively large computational time. Parallel supercomputers have the potential for significantly increasing calculation speeds in order to meet these computational requirements. This paper predicts parallel NIKE3D performance on the Kendall Square Research (KSR1) system. The first part of the prediction is based on the implementation of parallel Cholesky (U{sup T}DU) matrix decomposition algorithm through actual computations on the KSRI multiprocessor system, with 64 processors, at Oak Ridge National Laboratory. The other predictions are based on actual computations for parallel element matrix generation, parallel global stiffness matrix assembly, and parallel forward/backward substitution on the BBN TC2000 multiprocessor system at Lawrence Livermore National Laboratory. The ...

1995-05-01

336

Polymorphism in HTR3D shows different risks for acute chemotherapy-induced vomiting after anthracycline chemotherapy  

British Library Electronic Table of Contents (United Kingdom)

Aims: Serotonin (5-hydroxytryptamine 3; 5-HT3) receptors are involved in chemotherapy-induced nausea and vomiting (CINV), and 5-HT3 antagonists are part of the `gold standard' antiemetic treatment during chemotherapy. We investigated the correlation of common variants in 5-HT3 receptor subunit genes with the occurrence of CINV. Materials & methods: A total of 110 previously characterized chemotherapy-naive women with primary breast cancer treated with anthracycline-containing chemotherapy served as a study group for mutational analysis by direct sequencing. Eight common SNPs in the 5-HT3 receptor genes, HTR3A, HTR3B, HTR3D and HTR3E, were selected for association analysis. Results: A nonsynonymous variant in HTR3D, p.G36A (rs6443930), was found to be over-represented in nonresponders, assu...

2010-01-01

337

Core reactor calculation using the adaptive remeshing with a current error estimator  

International Nuclear Information System (INIS)

With the objective to improve the reactor physics calculation on a 2D and 3D nuclear reactor via the Diffusion Equation, an adaptive automatic finite element remeshing method, based on the elementary area (2D) or volume (3D) constraints, has been developed. The adaptive remeshing technique, guided by a posteriori error estimator, makes use of two external mesh generator programs: Triangle and TetGen. The use of these free external finite element mesh generators and an adaptive remeshing technique based on the current field continuity show that they are powerful tools to improve the neutron flux distribution calculation and by consequence the power solution of the reactor core even though they have a minor influence on the critical coefficient of the calculated reactor core examples. Two numerical examples are presented: the 2D IAEA reactor core numerical benchmark and the ...

338

Comprehensive simulations of superhumps  

CERN Document Server

(Abridged) We use 3D SPH calculations with higher resolution, as well as with more realistic viscosity and sound-speed prescriptions than previous work to examine the eccentric instability which underlies the superhump phenomenon in semi-detached binaries. We illustrate the importance of the two-armed spiral mode in the generation of superhumps. Differential motions in the fluid disc cause converging flows which lead to strong spiral shocks once each superhump cycle. The dissipation associated with these shocks powers the superhump. We compare 2D and 3D results, and conclude that 3D simulations are necessary to faithfully simulate the disc dynamics. We ran our simulations for unprecedented durations, so that an eccentric equilibrium is established except at high mass ratios where the growth rate of the instability is very low. Our improved simulations give a ...

2007-01-01

339

CFD analysis on the flow distribution of steam generator of SMART-P  

Energy Technology Data Exchange (ETDEWEB)

The Computational Fluid Dynamics(CFD) study was conducted to assess the new design concept introduced to solve the issues on the flow deviation between SG cassettes and the supporting structure design of the flow distributing plate subjected to the flow induced vibration. Flow field from MCP to the bottom of SG was modeled for 2-dimensional(2D) CFD analysis and then sensitivity analysis on major design parameters was conducted using commercial CFD code, Fluent. The cases for detailed 3D analysis were selected based on the result of 2D analysis and the detailed 3-dimensional(3D) analysis was conducted for these selected cases using Fluent code. Flow field was modeled by RNG model and wall function, 2nd upwind scheme, porous model, structured or hybrid grid. The analysis result shows that the maximum deviation of flow distribution between SG cassettes was reduced upto about 0.1% and the pressure loss from ...

2003-12-01

340

Accuracy of FEM 3-D modeling in the electromagnetic methods; Denjiho ni okeru FEM 3 jigen modeling no seido  

Energy Technology Data Exchange (ETDEWEB)

Analytical methods considering 3-D resistivity distribution, in particular, finite element method (FEM) were studied to improve the reliability of electromagnetic exploration. Integral equation, difference calculus, FEM and hybrid method are generally used as computational 3-D modeling method. FEM is widely used in various fields because FEM can easily handle complicated shapes and boundaries. However, in electromagnetic method, the assumption of continuous electric field is pointed out as important problem. The normal (orthogonal) component of current density should be continuous at the boundary between media with different conductivities, while this means that the normal component of electric field is discontinuous. In FEM, this means that current channeling is not properly considered, resulting in poor accuracy. Unless this problem is solved, FEM modeling is not practical. As one of the solutions, it ...

1996-10-01

341

A technique for the fast calculation of three-dimensional photon dose distributions using the superposition model  

International Nuclear Information System (INIS)

Techniques for reducing computation time in 3D photon dose calculations are addressed with specific emphasis given to the convolution/superposition approach. A single polyenergetic superposition model calculating absorbed dose per incident photon fluence (Gy cm"2) was developed in terms of TERMA and a total energy deposition kernel (a total point spread function). A novel approach was devised for reducing calculation time. The method, named the CF method, was based on the use of a conventional, fast model (here a modified power-law method was used) for the generation of 3D dose distributions on a fine dose matrix. Superposition calculations were carried out on a coarse matrix and calculation speed was increased simply by reducing the number of calculations. A set of correction factors was derived on the coarse grid from the ratio of the dose values from superposition to those from the conventional ...

1997-08-01

342

Staging the Crisis: Teaching, Capital, and the Politics of the Subject  

British Library Electronic Table of Contents (United Kingdom)

ABSTRACT This article proposes a philosophical reconstruction of the subject of the educator as the agent of curriculum. Starting from recent work in critical theory and philosophy, it describes the process of the existential crisis of the educator as the first step toward a truly critical education. The article argues that philosophy of curriculum must be concerned not just with forms of thought but also with forms of being-with the very ground of the subject and its real. This political ontology of the subject suggests a process of reconstruction consisting of several stages: the disclosure of ideology and complicity, the investigation of the process of interpellation, and the creation of a fundamentally collective educational practice. It is only on the basis of the effective staging of...

2010-01-01

343

Short term relative sea-level oscillations in Upper Devonian Nisku Formation (Alberta, Canada): application to hydrocarbon exploration and recent discoveries  

Energy Technology Data Exchange (ETDEWEB)

The relationship between short term relative sea-level oscillations and the reef, off-reef deposits geometry of an Upper Devonian third order sequence highstand of the Nisku Formation in west central Alberta was studied through the analysis of high resolution sequence stratigraphy. Hydrocarbon generation was reconstructed by total organic carbon values and migration patterns that were dependent on the geometry of three fourth order sequences. This stratigraphic reconstruction provided the key to recent hydrocarbon discoveries such as in the Brazeau southern reef margin.

1997-09-01

344

ITER Blanket First Wall (WBS 1.6{sub 1}A)  

Energy Technology Data Exchange (ETDEWEB)

International Thermonuclear Experimental Reactor (ITER) project is the international collaboration one for the commercialization of nuclear fusion energy through the technical and engineering verification. In ITER project, we plan to procure the blanket systems which has the risk of technology and cost when it is newly developed. We are developing the manufacturing process and joining technology for the ITER blanket to complete the procurement with qualified blanket system. To evaluate the soundness of manufacturing process, specimen and mock-up tests are being prepared. Finally, we can obtain the key technology of nuclear fusion reactor especially on the blanket design, joining and manufacturing technology through the present project and these technologies will help the construction of Korea fusion DEMO reactor and the development of commercial nuclear fusion reactor in Korea. In 1st year, through the fabrication of the Cu/SS and Be/Cu joint specimen, fabrication procedure such as ...

2008-03-15

345

Time-dependent 3-D dterministic transport on parallel architectures using Dantsys/MPI  

Energy Technology Data Exchange (ETDEWEB)

In addition to the ability to solve the static transport equation, we have also incorporated time dependence into our parallel 3-D S{sub {ital N}} code DANTSYS/MPI. Using a semi-implicit scheme, DANTSYS/MPI is capable of performing time-dependent calculations for both fissioning and pure source driven problems. We have applied this to various types of problems such as nuclear well logging and prompt fission experiments. This paper describes the form of the time- dependent equations implemented, their solution strategies in DANTSYS/MPI including iteration acceleration, and the strategies used for time-step control. Results are presented for a model nuclear well logging calculation.

1996-12-31

346

The effects of physical activity, education, and body mass index on the aging brain  

British Library Electronic Table of Contents (United Kingdom)

Abstract Normal human aging is accompanied by progressive brain tissue loss and cognitive decline; however, several factors are thought to influence brain aging. We applied tensor-based morphometry to high-resolution brain MRI scans to determine whether educational level or physical activity was associated with brain tissue volumes in the elderly, particularly in regions susceptible to age-related atrophy. We mapped the 3D profile of brain volume differences in 226 healthy elderly subjects (130F/96M; 77.9 3.6 SD years) from the Cardiovascular Health Study-Cognition Study. Statistical maps revealed the 3D profile of brain regions whose volumes were associated with educational level and physical activity (based on leisure-time energy expenditure). After controlling for age, sex, and physical...

2011-01-01

347

The CDF intermediate silicon layers detector  

Energy Technology Data Exchange (ETDEWEB)

The intermediate silicon layers detector (ISL) was proposed as a part of the upgraded CDF detector at the RUN-II of the Tevatron mean value of pp collider at Fermilab, scheduled to start in year 2000. The ISL is a large-radius (20-30 cm) silicon tracker with a total active area of about 3.5 m. Located in the region between the silicon vertex detector and the central outer tracker, the ISL will allow tracking in the forward region and significantly improve it in the central area. Together with the SVX II the ISL forms a standalone, 3D silicon tracker. The challenge is to build a low-cost device which provides precise 3 D tracking in a approximately equal to 2 m long area with a minimal amount of material for the supporting structure. The conceptual design and the status of the project are reviewed.

1999-11-01

348

Resonant neutralization of He ions into excited states at Cu(110) and Ni(110) surfaces  

Energy Technology Data Exchange (ETDEWEB)

He ions incident at grazing angles on Cu(110) and Ni(110) surfaces are neutralised into triplet and singlet states, of which the 3p, 3d and 4d upper states are accessible to optical spectroscopy. In the energy range from 500 eV to 15 keV no significant energy dependence of the relative intensities of singlet and triplet lines was observed for scattering on Cu(110). The intensities from Ni(110) are higher and the singlet to triplet intensity ratio of the 3d to 2p transition is about 6% smaller than that from Cu(110). The results can be explained well by assuming resonant charge capture into excited He and intermediate formation of negative He/sup -/ states.

1984-03-01

349

Resonant neutralization of He ions into excited states at Cu(110) and Ni(110) surfaces  

International Nuclear Information System (INIS)

He ions incident at grazing angles on Cu(110) and Ni(110) surfaces are neutralised into triplet and singlet states, of which the 3p, 3d and 4d upper states are accessible to optical spectroscopy. In the energy range from 500 eV to 15 keV no significant energy dependence of the relative intensities of singlet and triplet lines was observed for scattering on Cu(110). The intensities from Ni(110) are higher and the singlet to triplet intensity ratio of the 3d to 2p transition is about 6% smaller than that from Cu(110). The results can be explained well by assuming resonant charge capture into excited He and intermediate formation of negative He"- states. (orig.).

1983-07-01

350

On the anatomy of the adsorption heat versus loading as a function of temperature and adsorbate for a graphitic surface  

British Library Electronic Table of Contents (United Kingdom)

In this paper we review and classify the various patterns of isosteric heat versus loading for adsorption of gases on graphitised thermal carbon black at temperatures ranging from below the 3D triple point to temperatures above it, but less than the 3D critical point. We have identified the features of heat curve and highlighted the microscopic origin of these features. The patterns vary with temperature and with the relative strength of the fluid-fluid interaction and solid-fluid interaction. For simple adsorptives (by simple we meant there is no strong association between fluid particles), the heat curve is typified by fluid-fluid attraction and layering phenomena. For adsorptives showing strong association such as water, ammonia and methanol, the heat curve essentially begins below the ...

2008-01-01

351

Improved recovery demonstration for Williston Basin carbonates. Quarterly report, July 1 - September 30, 1996  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this project is to demonstrate targeted infill and extension drilling opportunities, better determinations of oil-in- place, methods for improved completion efficiency and the suitability of waterflooding in certain shallow-shelf carbonate reservoirs in the Williston Basin, Montana, North Dakota and South Dakota. Improved reservoir characterization utilizing 3-dimensional (3D) and multi-component seismic are being investigated for identification of structural and stratigraphic reservoir compartments. Field demonstrations are in progress to collect data for evaluation of horizontal completions in both the Red River and Ratcliffe. A vertical well in the Red River will test attribute analysis of 3D seismic data for prediction of porosity development. Additional seismic acquisitions and interpretation are in progress for both the Ratcliffe and Red River. A water-injectivity test in a new ...

1996-12-31

352

Effect of varying the vertical dimension of connectors of cantilever cross-arch fixed dental prostheses in patients with severely reduced osseous support: A three-dimensional finite element analysis  

British Library Electronic Table of Contents (United Kingdom)

Statement of problem Inadequate dimensioning of the connectors in a cantilever cross-arch fixed dental prosthesis (FDP) in perioprosthetic patients jeopardizes the prognosis of the restoration. Purpose The purpose of this study was to investigate the effect of increasing the vertical dimension (VD) on the maximum stress developed within the connectors during the static loading of a cross-arch FDP extended as a 1- and 2-unit cantilever. Material and methods Six digital models were developed, derived from a 3-dimensional (3-D) initial model. In the initial model, the teeth were prepared for metal ceramic restorations and splinted with a cross-arch FDP, extended as a 1- or 2-unit cantilever. The VDs of the connectors proximal to the retaining abutment were 3, 4, or 5 mm. A 3-D finite element ...

2010-01-01

353

Discretization of complex 3-D flow domains with adaptive hybrid grids  

Energy Technology Data Exchange (ETDEWEB)

There is an ever increasing demand to perform flow simulations that incorporate the complete details of geometry as well as sophisticated flow physics. This has led to the development of numerical algorithms that can simulate the actual flow phenomena with greater fidelity. However, the success of these algorithms hinges on the grid that models the geometry. Grid generation methods for 2-D models have long existed and the general lack of complexity of the simpler 2-D models has not quite challenged the efforts in this area. However, demands for generating better 3-D geometric models for flow simulations involving complex geometries have completely changed the perspective of grid generation strategies. As a consequence, grid generation efforts have earned equal significance as that of numerical solver efforts.

1996-12-31

354

Development of Computational Models for Pyrochemical Electrorefiners of Nuclear Waste Transmutation Systems  

International Nuclear Information System (INIS)

The objective of this project is to develop multi-dimensional computational models in order to improve the operation of uranium electrorefiners currently used in pyroprocessing technology. These 2-D (US) and 3-D (ROK) mathematical models are based on the fundamental physical and chemical properties of the electrorefiner processes. The validated models by compiled and evaluated experimental data could provide better information for developing advanced electrorefiners for uranium recovery. The research results in this period are as follows: - Successfully assessed a common computational platform for the modeling work and identify spatial characterization requirements. - Successfully developed a 3-D electro-fluid dynamic electrorefiner model. - Successfully validated and benchmarked the two multi-dimensional models with compiled experimental data sets

2008-08-01

355

Contribution to 3D-operational geodesy. Pt. 3  

Energy Technology Data Exchange (ETDEWEB)

Whereas in part 1 and 2 the detailed observation equations of terrestrial type for an integrated geodetic model are presented this paper will outline how the theory is transferred in an operational program. The main lines of functions of the FORTRAN IV program are discussed. Since the input specifications as well as the data requirements are described in detail and illustrated by example of input and output part 3 can serve as an user-guide for OPERA. OPERA is an acronym for operational adjustment. Besides the integrated determination of 3D-geocentric coordinates and the gravity disturbing potential the program can handle all cases of traditional geodesy (in total 13 variants of solution are provided) equivalent also with adjustments in ellipsoidal coordinates B, L or H, as well as constrained adjustments, pure prediction of the gravity disturbing field, etc.

1983-01-01

356

Constrained NBMPR analogue synthesis, pharmacophore mapping and 3D-QSAR modeling of equilibrative nucleoside transporter 1 (ENT1) inhibitory activity  

British Library Electronic Table of Contents (United Kingdom)

Conformationally constrained analogue synthesis was undertaken to aid in pharmacophore mapping and 3D-QSAR analysis of nitrobenzylmercaptopurine riboside (NBMPR) congeners as equilibriative nucleoside transporter 1 (ENT1) inhibitors. In our previous study [J. Med. Chem. 2003, 46, 831-837], novel regioisomeric nitro-1,2,3,4-tetrahydroisoquinoline conformationally constrained analogues of NBMPR were synthesized and evaluated as ENT1 ligands. 7-NO2-1,2,3,4-Tetrahydroisoquino-2-yl purine riboside was identified as the analogue with the nitro group in the best orientation at the NBMPR binding site of ENT1. In the present study, further conformational constraining was introduced by synthesizing 5prime-O,8-cyclo derivatives. The flow cytometrically determined binding affinities indicated that the...

2008-01-01

357

Application of Vertically Integrated Electronics to Intelligent Trackers  

CERN Document Server

At Super-LHC luminosity it is expected that the standard suite of L1 triggers for CMS will saturate. Information from the tracker will be needed to reduce trigger rates to satisfy the L1 bandwidth. Tracking trigger modules which correlate information from closely-spaced sensor layers to form an on-detector momentum filter are being developed by several groups. We report on a trigger module design which utilizes three dimensional IC technology to incorporate chips which are connected both to the top and bottom sensor, providing the ability to filter information locally. A demonstration chip, the VICTR, has been submitted to the Chartered/Tezzaron two-tier 3D run coordinated by Fermilab. We report on the 3D design concept, the status of the VICTR chip and associated sensor integration utilizing oxide bonding.

2010-01-01

358
360

Simple fractal method of assessment of histological images for application in medical diagnostics  

UK PubMed Central (United Kingdom)

We propose new method of assessment of histological images for medical diagnostics. 2-D image is preprocessed to form 1-D landscapes or 1-D signature of the image contour and then their complexity is...Full Text Available

361
368

Images of photoreceptors in living primate eyes using adaptive optics two-photon ophthalmoscopy  

UK PubMed Central (United Kingdom)

In vivo two-photon imaging through the pupil of the primate eye has the potential to become a useful tool for functional imaging of the retina. Two-photon excited fluorescence images...Full Text Available

369

Image Engine: an object-oriented multimedia database for storing, retrieving and sharing medical images and text.  

UK PubMed Central (United Kingdom)

This paper describes Image Engine, an object-oriented, microcomputer-based, multimedia database designed to facilitate the storage and retrieval of digitized biomedical still images, video, and text...Full Text Available

1993-01-01

376

Adaptive Image Processing A Computational Intelligence Perspective  

CERN Document Server

Adaptive image processing is one of the most important techniques in visual information processing, especially in early vision such as image restoration, filtering, enhancement, and segmentation. This work focuses on applications of advanced CI techniques in image processing applications

2009-01-01

377

Real time neutron radiography using a Lixi neutron imaging device  

Energy Technology Data Exchange (ETDEWEB)

A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Illinois. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain ...

1986-01-15

378

Real time neutron radiography using a Lixi neutron imaging device  

International Nuclear Information System (INIS)

A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Ill. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain ...

1986-01-01

379

Advances in Modeling of Scanning Charged-Particle-Microscopy Images  

CERN Document Server

Modeling artificial scanning electron microscope (SEM) and scanning ion microscope images has recently become important. This is because of the need to provide repeatable images with a priori determined parameters. Modeled artificial images are highly useful in the evaluation of new imaging and metrological techniques, like image-sharpness calculation, or drift-corrected image composition (DCIC). Originally, the NIST-developed artificial image generator was designed only to produce the SEM images of gold-on-carbon resolution sample for image-sharpness evaluation. Since then, the new improved version of the software was written in C++ programming language and is in the Public Domain. The current version of the software can generate arbitrary samples, any drift function, and many other features. This ...

2010-01-01

380

Magnetic resonance imaging in childhood epilepsy  

International Nuclear Information System (INIS)

The suitability of MR imaging versus computerized tomography in observation of brain development disorders in children are compared. 13 refs.

381

Esters useful as brain imaging agents  

Energy Technology Data Exchange (ETDEWEB)

Certain radioiodine containing esters useful as brain imaging agents are disclosed. The formula of these compounds are presented.

1981-08-18

382

Esters useful as brain imaging agents  

International Nuclear Information System (INIS)

Certain radioiodine containing esters useful as brain imaging agents are disclosed. The formula of these compounds are presented.

383

Amides useful as brain imaging agents  

Energy Technology Data Exchange (ETDEWEB)

Certain radioiodine containing amides useful as brain imaging agents are disclosed. The compounds of the subject invention are represented by the formula

1981-07-21

384

Amides useful as brain imaging agents  

International Nuclear Information System (INIS)

Certain radioiodine containing amides useful as brain imaging agents are disclosed. The compounds of the subject invention are represented by the formula.

385

Computed Tomography of the diabetic kidney; La Tomografia Computerizzata nello studio del rene diabetico  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this work is to investigate whether any morphometric or densitometric are detectable in the kidneys of type 2 diabetic patients. 40 diabetic patients were examined and of 20 non-diabetics (the control group) were submitted to triphasic helical CT for different abdominal conditions. The type 2 diabetic patients were 23 men and 17 women, mean age 62 years, while the nondiabetic controls were 12 men and 8 women, mean age 58 years. All the CT images were analyzed using the Multiplanar Reconstruction (MPR) software. It was evaluated morphometric features, such as the presence of parenchymal or vascular calcifications, axial and coronal renal diameters, coronal renal area, and cortico medullary ratio, and densitometric and functional features, such as unenhanced renal density, cortical and medullary density in the arterial phase, parenchymal density in the nephrographic phase, and contrast elimination. It was also compared the results ...

2000-02-01

386

Image-enhancement applications at the Lawrence Livermore National Laboratory  

Energy Technology Data Exchange (ETDEWEB)

A diverse set of digital image-processing applications exists at the Lawrence Livermore National Laboratory. While many of these include some sort of image analysis or restoration, virtually all of them require image-enhancement procedures. In this paper we describe the principal image-processing facility at the Laboratory, followed by a discussion of several of the major image-processing application areas.

1982-06-01

387

m0905250.imq  

Science.gov (United States)

zb l:7R cq~` ;qqw scq- !;m#] QLBr90 NJThh 4vwCb :o5!3: $|1y .8Bj -A}8 -^uY .,4G WDl7 72qBD ;tDGCq MXgF 9[1"r3 :D)nJ+ &&orq l'j"c/ Lk^q 't|#b c3~5 :&c|$ ...

388

The chemistry of the p-block elements with thioether, selenoether and telluroether ligands.  

Science.gov (United States)

The synthesis and structures of acyclic and macrocyclic thio-, seleno- and telluro-ether complexes of the metallic and metalloid elements of Groups 13-16 reported since 2000 are described. The diverse structures range from discrete monomers through to infinite 1-, 2- or 3-D polymers. The coordination chemistry in this area is quite different to familiar d-block chemistry and the underlying factors are explored. PMID:21706103

2011-06-27

389

Steam generator PGV-1000 thermal-hydraulics  

International Nuclear Information System (INIS)

The main features are presented of a computer programme for 3-D thermohydraulic and thermodynamic analysis of the PGV-1000 horizontal steam generator used at the Temelin NPP. The programme provides analyses of primary side hydraulics, heat exchange behavior and the steam generator secondary side thermohydraulics and thermodynamics. Given are calculated data on the circulation flow rate, void fraction, heat transfer dynamics and the swelled level. (Z.S.) 9 figs.

1995-09-21

390

On the calculation of scattered fields by 3-D structure in the time-domain electromagnetic (TDEM) method; Jikan ryoiki denjiho ni okeru sanjigen kozo kara no sanranba no keisan ni tsuite  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the calculation method of 3-D underground structures in TDME method which measures only field components. Recently, FDTD method was developed as calculation method in time domain difference calculus, and the forward analysis accuracy of 3-D fields was rapidly improved. The survey results using a large-scale loop (600m{times}360m) were numerically analyzed by FDTD method. 16 measuring lines were prepared in both X and Y directions, and measuring points were prepared on intersection points of the measuring lines. Since signal current is staircase one, step and impulse responses of the ground were determined by calculating magnetic field and its time differentiation. The rectangular body (120m{times}120m{times}100m) of 0.2S/m in conductivity (5 ohm m in resistivity) was installed 160m under the ground as 3-D resistivity anomaly. The ground of ...

1996-10-01

391

Magnetic and valence transitions in CePd_2_-_xMn_xSi_2:L_I_I_I edge study  

International Nuclear Information System (INIS)

We report on solid solution CePd_2_-_xMn_xSi_2 which shows an interesting transition of the Ce-ion from magnetism in a Kondo regime to an intermediate valence state coupled with a strongly magnetic 3d sublattice. ((orig.)).

392

Magnetic and valence transitions in CePd[sub 2-x]Mn[sub x]Si[sub 2]:L[sub III] edge study  

Energy Technology Data Exchange (ETDEWEB)

We report on solid solution CePd[sub 2-x]Mn[sub x]Si[sub 2] which shows an interesting transition of the Ce-ion from magnetism in a Kondo regime to an intermediate valence state coupled with a strongly magnetic 3d sublattice. ((orig.))

1994-04-01

393

Horizontal Steam Generator Thermal-Hydraulics at Various Steady-State Power Levels  

Science.gov (United States)

Three-dimensional computer simulation and analyses of the horizontal steam generator thermal-hydraulics of the WWER 1000 nuclear power plant have been performed for 50% and 75% partial loads, 100% nominal load and 110% over-load. Presented results show water and steam mass flow rate vectors, steam void fraction spatial distribution, recirculation zones, swell level position, water mass inventory on the shell side, and other important thermal-hydraulic parameters. The simulations have been performed with the computer code 3D ANA, based on the 'two-fluid' model approach. Steam-water interface transport processes, as well as tube bundle flow resistance, energy transfer, and steam generation within tube bundles are modelled with {sup c}losure laws{sup .} Applied approach implies non-equilibrium thermal and flow conditions. The model is solved by the control volume procedure, which has been extended in order to take into account ...

2002-07-01

394

Horizontal Steam Generator Thermal-Hydraulics at Various Steady-State Power Levels  

International Nuclear Information System (INIS)

Three-dimensional computer simulation and analyses of the horizontal steam generator thermal-hydraulics of the WWER 1000 nuclear power plant have been performed for 50% and 75% partial loads, 100% nominal load and 110% over-load. Presented results show water and steam mass flow rate vectors, steam void fraction spatial distribution, recirculation zones, swell level position, water mass inventory on the shell side, and other important thermal-hydraulic parameters. The simulations have been performed with the computer code 3D ANA, based on the 'two-fluid' model approach. Steam-water interface transport processes, as well as tube bundle flow resistance, energy transfer, and steam generation within tube bundles are modelled with "closure laws". Applied approach implies non-equilibrium thermal and flow conditions. The model is solved by the control volume procedure, which has been extended in order to take into account the ...

2002-04-14

395

Comparison of EH with SW-Xsub(alpha) calculations  

International Nuclear Information System (INIS)

The electronic structure of octahedral metal atom clusters Me_6 of 3d, 4d, and 5d transition metal atoms (V, Cr; Nb, Mo; Ta, W) has been calculated applying two different quantum-chemical approximation methods (Extended Hueckel (EH) method; SW-Xsub(alpha) method). Equilibrium structures, energy level schemes, Fermi energies and band widths as well as densities of states of clusters are discussed in detail.

1981-01-01

396

Calculation of 3-D electrical field distribution around technical devices in the vicinity of high voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

The influence that electromagnetic fields have on mechanical and electronic equipment was discussed. A three dimensional numerical simulation model of electric fields around high voltage power transmission lines was described. 4 refs., 1 tab., 5 figs.

1997-12-31

397

Calculation of 3-D electrical field distribution around technical devices in the vicinity of high voltage transmission lines  

International Nuclear Information System (INIS)

The influence that electromagnetic fields have on mechanical and electronic equipment was discussed. A three dimensional numerical simulation model of electric fields around high voltage power transmission lines was described. 4 refs., 1 tab., 5 figs.

1997-08-24

398

3D Time-Dependent Model Of The Dusty-Gas Atmosphere Of Comet 67P/Churyumov-Gerasimenko: Recent Improvements.  

Science.gov (United States)

Under support from the French Space Agency (CNES), a 3D+t dusty-gas model of Comet 67P/Churyumov-Gerasimenko is being developed, to compute, from the first 2014 Rosetta orbital data, the aerodynamic forces exerted on the Rosetta orbiter and on the descent lander. We report the recently developed dust dynamics part of the code. The multi-species (presently H2O and CO) gas code is optimized in terms of computational speed owing to the use of two complementary methods: (a) 3D+t Direct Simulation Monte Carlo (DSMC) runs in the non-equilibrium regions adjacent to the surface and very distant from it, and (b) solutions of the Navier-Stokes equations in-between. The model is used presently using Lamy et al. (Space Sci. Rev., 2007, 128, 23) coarse information on 67P nucleus shape and rotation, and a range of possible gas production rates Q for the early Rosetta observations at rh 3 AU (Q 1026 - 1027 s-1). In ...

2010-10-01

399

3-D numerical simulation of the transient electromagnetic pulse coupling to double cylinder object  

International Nuclear Information System (INIS)

In this paper, finite-difference time-domain method is used to research the transient electromagnetic pulse (EMP) coupling to the cylinder object which is shielded in another shielding cavity with a hole numerically. The different coupling effectiveness of three transient EMP is simulated. The distribution of the electric field in the shielding cavity and the current on the cavity are researched. The shielding effectiveness is evaluated. (authors)

2006-10-21

400

28: Calculation of 3D dose distribution for photons in inhomogeneous media  

International Nuclear Information System (INIS)

A method for calculation of absorbed dose distributions in three dimensions for 1-20 MeV photons is presented. The method uses convolution/superposition of photon fluence distributions with energy scattering kernels. Results for Co-60 and X-ray beams in homogeneous and inhomogeneous media are compared with measurements. Good agreement is found between calculations and measurements. 8 refs.; 3 figs.

401

An Effective Method of Image Retrieval using Image Mining Techniques  

CERN Document Server

The present research scholars are having keen interest in doing their research activities in the area of Data mining all over the world. Especially, [13]Mining Image data is the one of the essential features in this present scenario since image data plays vital role in every aspect of the system such as business for marketing, hospital for surgery, engineering for construction, Web for publication and so on. The other area in the Image mining system is the Content-Based Image Retrieval (CBIR) which performs retrieval based on the similarity defined in terms of extracted features with more objectiveness. The drawback in CBIR is the features of the query image alone are considered. Hence, a new technique called Image retrieval based on optimum clusters is proposed for improving user interaction with image retrieval systems by fully exploiting ...

2010-01-01

402

High-resolution beta imaging; L'imagerie beta haute resolution  

Energy Technology Data Exchange (ETDEWEB)

For many years, {beta} radioactivity has been used to label molecules and follow them in various biological processes. {beta} imaging is obtained by autoradiography. Classically made on films or on photographic emulsions, autoradiography is now supplanted by radio-imagers which are very performing. The phosphor-imager, {beta}-imager and {mu}-imager are the systems mainly used today and their operating principles and properties are compared. The great advantages of these imagers are: their rapidity to obtain results and their reliability for absolute quantification. All emitters ({beta}{sup -}, {beta}{sup -} -{gamma} and {beta}{sup +}) are detectable as well as the gamma emitters of nuclear medicine, by means of their low energy electrons ejected during y emission. Phosphor-imager is well suited to energetic tracers and large series of ...

2007-04-15

403

Tomographic measurements of carbon monoxide temperature and concentration in a Bunsen flame using diode laser absorption  

Energy Technology Data Exchange (ETDEWEB)

Temperature and concentration profiles of CO in a laminar, axisymmetric, premixed methane-air Bunsen flame are measured using line-of-sight diode laser absorption spectroscopy and computer tomographic (CT) reconstruction. Absorption spectra for P(20) (v=2<-1) and P(27) (v=1<-0) vibrotational transitions of CO were measured at 21 evenly spaced positions over a 1.33 cm span for a 1.3 cm radius flame. CT reconstruction algorithm was based on Fourier convolution. The tomographically reconstructed normalized transmission profiles derived from absorption spectra, in conjunction with a quantum mechanical model for vibrotational behavior of CO, yielded both temperature and concentration profiles. The Bunsen flame had 3 distinct zones: an inner rich-premixed flame zone, an outer non-premixed flame zone and an unburnt core region. The reconstructed temperature profile showed that the core region temperature ...

1993-12-01

404

Value of contrast-enhanced MRI of breast after silicone implant; Wertigkeit der Kontrastmittelmagnetresonanztomographie der Mamma bei Wiederaufbau mittels Implantat  

Energy Technology Data Exchange (ETDEWEB)

Early recognition of recurrence and work-up of clinically indeterminate lesions may be impaired after reconstruction with silicone implants due to superimposition of the implant or to scarring. This study was undertaken to evaluate the use of contrast-enhanced MRI in patients with silicone implant after breast cancer. Contrast-enhanded MRI was offered to 169 patients. Comparative two- to three-view mammography was also performed in 169 patients, as well as comparative sonography in 144 patients. Conventional imaging and clinical examination detected only 8/13 recurrences, whereas 12/13 were detected by MRI. One recurrence had been visible as a strongly enhancing 2-mm dot in a previous examination (2 years before), but was not called. It was therefore counted as false negative. In addition, multicentricity was detected by MRI alone in two of three cases. MRI correctly diagnosed scar tissue in all cases with indeterminate findings. However, due ...

1997-09-01

405

Radiation exposure of children in pediatric radiology. Pt. 6. Conversion factors for reconstruction of organ dose in abdominal radiography; Zur Strahlenexposition von Kindern in der paediatrischen Radiologie. T. 6. Konversionsfaktoren zur Rekonstruktion von Organdosen bei Abdomenaufnahmen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: calculation of conversion coefficients for the reconstruction of organ doses from entrance doses for abdomen radiographs of 0, 1, 5, 10, 15, and 30-year-old patients in conventional pediatric radiology for the radiographic settings recommended by the German and European guidelines for quality management in diagnostic radiology. Materials und method: using the commercially available personal computer program PCXMC developed by the Finnish Center for Radiation and Nuclear Safety (Saeteilyturvakeskus STUK), conversion coefficients for conventional abdomen radiographs were calculated performing Monte Carlo simulations in mathematical hermaphrodite phantom models describing patients of different ages. The possible clinical variation of beam collimation was taken into consideration by defining optimal and suboptimal radiation fields on the phantoms' surfaces. Results: conversion coefficients for the reconstruction of organ does in ...

2009-10-15

406

OSCAAR calculations for the Iput dose reconstruction scenario of BIOMASS theme 2  

Energy Technology Data Exchange (ETDEWEB)

This report presents the results obtained from the application of the accident consequence assessment code, called OSCAAR, developed in Japan Atomic Energy Research Institute to the Iput dose reconstruction scenario of BIOMASS Theme 2 organized by International Atomic Energy Agency. The Iput Scenario deals with {sup 137}Cs contamination of the catchment basin and agricultural area in the Bryansk Region of Russia, which was heavily contaminated after the Chernobyl accident. This exercise was used to test the chronic exposure pathway models in OSCAAR with actual measurements and to identify the most important sources of uncertainly with respect to each part of the assessment. The OSCAAR chronic exposure pathway models almost successfully reconstructed the whole 10-year time course of {sup 137}Cs activity concentrations in most requested types of agricultural products and natural foodstuffs. Modeling of {sup 137}Cs downward migration in soils is, ...

2001-01-01

407

Experimental studies on reconstruction of peripheral arteries by high voltage cathode ray irradiated allografts  

International Nuclear Information System (INIS)

The use of cathode ray irradiated arterial allografts on the reconstruction of small peripheral arteries is described. The fate of irradiated arterial allografts implanted subcutaneously in rats was compared histologically with that of allografts which were fresh, frozen or stored in 70% alcohol. Follow-up studies were made of 10 dogs in which irradiated arterial allografts had been implanted in the femoral artery to be evaluated; long term patency by arteriography, gross and histologic changes of the implanted allografts, and the luminal surface of the implanted allografts by scanning electron microscopic studies. For the purpose of antigenic studies, extracts of canine arteries which had been irradiated, frozen or stored in 70% alcohol, were prepared and tested by the following immunological methods: precipitation, Ouchterlony gel diffusion, and passive cutaneous anaphylaxis. From the results obtained in these experiments, it was concluded that, compared with ...

1976-01-01

408

A convolution/superposition method using primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance: a theoretical study on 10-MV X-ray dose calculations in thorax-like phantoms  

British Library Electronic Table of Contents (United Kingdom)

A convolution/superposition method is proposed for use with primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. It should be noted that the number of energy bins is usually about ten, and that the reconstructed X-ray spectra can reasonably be applied to media with a wide range of effective Z numbers, ranging from water to lead. The study was carried out for 10-MV X-ray doses in water and thorax-like phantoms with the use of open-jaw-collimated fields. The dose calculations were made separately for primary, scatter, and electron contamination dose components, for which we used two extended radiation sources: one was on the X-ray target and the other on the flattening filter. To calculate the in-air beam intensities at po...

2011-01-01

409

CR portal imaging; A linac graphy using storage phosphor imaging systems  

Energy Technology Data Exchange (ETDEWEB)

In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In ...

1992-07-01

410

Radioisotope imaging of brain tumors in two rhesus monkeys. Final report  

Energy Technology Data Exchange (ETDEWEB)

Two geriatic male rhesus monkeys were used for the radioisotope imaging in this research. Discussion of the radionuclide, materials, and method used to accomplish the neurologic examination and the results obtained, both during the procedure and confirmation of the results by necropsies were accompanied by color photos of scan images. Results were that the nuclear images provided accurate images of intracranial neoplasia.

1988-04-01

411

Impact of computers in radiography: the advent of digital radiography, part-2  

International Nuclear Information System (INIS)

Computed radiography (CR) systems use a photostimulable phosphor plate enclosed in a cassette. In CR, image acquisition is a two-stage process wherein image capture and image read out are done separately. Direct digital radiography (DR) systems, on the other hand, use detectors that have a combined image capture and image read out capability. DR systems are also called as DDR or ddR systems by some vendors. This article focuses on DR systems

2008-08-01

412

Fracture imaging with converted elastic waves  

Energy Technology Data Exchange (ETDEWEB)

This paper examines the seismic signatures of discrete, finite-length fractures, and outlines an approach for elastic, prestack reverse-time imaging of discrete fractures. The results of this study highlight the importance of incorporating fracture-generated P-S converted waves into the imaging method, and presents an alternate imaging condition that can be used in elastic reverse-time imaging when a direct wave is recorded (e.g., for crosswell and VSP acquisition geometries).

2001-05-29

413

The CDF II eXtremely Fast Tracker Upgrade  

International Nuclear Information System (INIS)

The CDF II eXtremely Fast Tracker (XFT) is the trigger processor which reconstructs charged particle tracks in the CDF II central outer tracking chamber. The XFT tracks are also extrapolated to the electromagnetic calorimeter and muon chambers and are associated to electromagnetic clusters and muon stubs to generate trigger electron and muon candidates. The steady increase of the Tevatron instantaneous luminosity and the resulting higher occupancy of the chamber demanded an upgrade of the original system, which performed tracking only in the transverse plane of the chamber and was consequently affected by a significant level of fake tracks. In the upgraded XFT, tracking is reinforced by using additional data from the stereo layers of the chamber to reduce the level of fake tracks and to perform three-dimensional track reconstruction. A review of this upgrade is presented.

2007-10-21

414

Remotely sensing of excavation cavity during mining  

Energy Technology Data Exchange (ETDEWEB)

This patent describes a method of hydraulically mining a surface of a mining location comprising: a. determining the dimensions of the surface of the mining location from a fixed point at the location; b. constructing at a second location remote from the mining location a visual representation of the surface form the determined dimensions of the mining location with respect to the fixed point; c. jetting water under high pressure against a selected area on the surface of the mining location; d. determining changes in the dimensions of the selected area of the surface of the mining location; e. reconstructing at the second location a new visual representation of the surface from the determined changes of the location during the jetting of the water; and f. redirecting the jetted water under high pressure utilizing data from the reconstructed visual representation.

1987-11-24

415

Measurement of W{sup {+-}} boson mass at LEP by means of DELPHI detector; Mesure de la masse des bosons W{sup {+-}} au LEP a l`aide du detecteur DELPHI  

Energy Technology Data Exchange (ETDEWEB)

The thesis deals with measurement of the mass of the W boson at LEP2, based on the direct reconstruction of its decay products in the hadronic channel. A set of procedures necessary for the extraction of the W mass from the experimental data collected with the DELPHI detector in 1997 was developed (search of optimal variables for the event selection, development of a special method of kinematical reconstruction). The measured value of the mass was interpreted in the framework of the Standard Model, allowing to constrain the mass of the Higgs boson. A substantial part of the work is devoted to systematic effects due to the interactions between the hadronic decay products of the W bosons (colour reconnection and Bose-Einstein correlations), which may significantly influence the measurement of their mass. (author) 53 refs., 104 figs., 33 tabs.

1998-05-25

416

Establishment and clonal spread of the alien shrub Rosa rugosa in coastal dunes-A method for reconstructing and predicting invasion patterns  

British Library Electronic Table of Contents (United Kingdom)

Little is known about the rates of establishment and clonal spread of invasive plants on a landscape scale. This knowledge is necessary for reconstructing and predicting invasions, for example of the alien shrub Rosa rugosa. A series of aerial photographs (1986, 1999, 2002, 2004, 2006) were used to map the species in coastal dunes of north-western Denmark (2354ha), and all R. rugosa patches (1321) were recorded with GPS in 2004 and 2007. The 2004 records were used to digitize 82-161 distinct patches on the photographs. The increase in patch sizes from the older to the younger photographs was used to calculate a lateral clonal spread rate (0.42myear^-^1). Relative area increment by clonal spread was 16.4% per year, decreasing exponentially with patch size due to constant clonal lateral spre...

2009-01-01

417

Curative resection of a huge malignant pancreatic endocrine tumor by pancreatoduodenectomy with portal and superior mesenteric vein resection and reconstruction using the right ovarian vein: Report of a case  

British Library Electronic Table of Contents (United Kingdom)

Nonfunctioning pancreatic endocrine tumors (PETs) are rare and generally asymptomatic. A 68-year-old woman who had refused treatment for a pancreatic mass, revealed by ultrasonography to be 55 mm in diameter, was referred to us again 29 months later with jaundice. Investigations showed an 82-mm tumor in the head of pancreas, exposed from the papilla of Vater to the duodenal lumen. After biliary decompression and drainage, we performed pancreatoduodenectomy with resection of the portal vein and superior mesenteric vein, followed by reconstruction using a cylindrically customized autologous graft harvested from the right ovarian vein. The tumor was resected curatively. Microscopically, it consisted of trabecular and ribbon-like arrangement of neoplastic cells. Immunohistochemical staining wa...

2011-01-01

418

Chitons (Mollusca, Polyplacophora) du Pleistocene tardif et de l'Holocene d'Uruguay : paleobiogeographie et reconstruction paleoenvironnementale aux latitudes moyennes de l'Atlantique du sud-ouest  

British Library Electronic Table of Contents (United Kingdom)

Here we present a revision of the fossil record of chitons (Mollusca, Polyplacophora) of Late Pleistocene and Holocene marine deposits of Uruguay and discuss their potential for palaeoenvironmental reconstruction. Chitons were recorded as isolated valves in bivalve- and gastropod-rich assemblages. They are represented by the species Chaetopleura angulata (Spengler), C. isabellei (d'Orbigny), C. asperrima (Gould) and Ischnochiton striolatus (Gray). The last two species are recorded for the first time as fossils not only in Uruguay but also in South America. Exclusively recorded for the Late Pleistocene is the warm water species I. striolatus, whose current southern range limit is located in Santa Catarina, Brazil. Higher temperatures than at present are inferred for the Uruguayan coast duri...

2011-01-01

419

Application of microvascular free osteocutaneous flaps in the management of post-radiation recurrent oral cancer  

Energy Technology Data Exchange (ETDEWEB)

Fifty-nine patients underwent free flap osteocutaneous reconstruction that consisted of flaps of the dorsum of the foot in 26 patients and iliac crest flaps in 33 with a success rate of 92 percent and a mortality rate of 1.6 percent. These flaps, which require the expertise of microvascular surgeons, are time-consuming and complicate operating room and time management, but they represent a remarkable advance in reconstruction that can facilitate cosmetic and functional recovery of the patient. In particular, they promote healing in radiation-recurrent oral cancer and represent a definitive form of management for established radionecrosis of the mandible. The large volume of tissue available with iliac crest osteocutaneous grafts permits the management of patients with extensive cancer involving the skin, mucosa, and bone, but cancer control may still be disappointing and there is a need for improved adjuvant chemotherapy protocols. This ...

1985-10-01

420

An effective method to estimate multidimensional Gaussian states  

CERN Document Server

A simple and efficient method for characterization of multidimensional Gaussian states is suggested and experimentally demonstrated. Our scheme shows analogies with tomography of finite dimensional quantum states, with the covariance matrix playing the role of the density matrix and homodyne detection providing Stern-Gerlach-like projections. The major difference stems from a different character of relevant noises: while the statistics of Stern-Gerlach-like measurements is governed by binomial statistics, the detection of quadrature variances correspond to chi-square statistics. For Gaussian and near Gaussian states the suggested method provides, compared to standard tomography techniques, more stable and reliable reconstructions. In addition, by putting together reconstruction methods for Gaussian and arbitrary states, we obtain a tool to detect the non-Gaussian character of optical signals.

2009-01-01

421

A numerical study of ultra-short-pulse reflectometry  

Energy Technology Data Exchange (ETDEWEB)

Ultra-short-pulse reflectometry is studied by means of the numerical integration of a one-dimensional full-wave equation for ordinary modes propagating in a plasma. The numerical calculations illustrate the potential of using the reflection of ultra-short-pulse, microwaves as an effective probe of the density profile even in the presence of significant density fluctuations. The difference in time delays of differing frequency components of the microwaves can be used to deduce the density profile. The modification of the reflected pulses in the presence of density fluctuations is examined and can be understood based on considerations of Bragg resonance. A simple and effective profile-reconstruction algorithm using the zero-crossings of the reflected pulse and subsequent Abel inversion is demonstrated. The robustness of the profile reconstruction algorithm in the presence of a sufficiently small amplitude density perturbation is assessed.

1994-05-01

422

MULTICOMPONENT SEISMIC ANALYSIS AND CALIBRATION TO IMPROVE RECOVERY FROM ALGAL MOUNDS: APPLICATION TO THE ROADRUNNER/TOWAOC AREA OF THE PARADOX BASIN, UTE MOUNTAIN UTE RESERVATION, COLORADO  

Energy Technology Data Exchange (ETDEWEB)

This report describes the results made in fulfillment of contract DE-FG26-02NT15451, ''Multicomponent Seismic Analysis and Calibration to Improve Recovery from Algal Mounds: Application to the Roadrunner/Towaoc Area of the Paradox Basin, Ute Mountain Ute Reservation, Colorado''. Optimizing development of highly heterogeneous reservoirs where porosity and permeability vary in unpredictable ways due to facies variations can be challenging. An important example of this is in the algal mounds of the Lower and Upper Ismay reservoirs of the Paradox Basin in Utah and Colorado. It is nearly impossible to develop a forward predictive model to delineate regions of better reservoir development, and so enhanced recovery processes must be selected and designed based upon data that can quantitatively or qualitatively distinguish regions of good or bad reservoir permeability and porosity between existing well control. Recent advances in seismic acquisition and ...

2003-07-10

423

The Possibility of Digital Imaging in the Diagnosis of Occlusal Caries  

UK PubMed Central (United Kingdom)

The aim of this study was to assess the possibility of digital image analysis of pit-and-fissure discoloration in order to diagnose caries. Digital images showing pit-and-fissure discoloration in 100...Full Text Available

2010-01-01

424

Selective imaging of adherent targeted ultrasound contrast agents  

UK PubMed Central (United Kingdom)

The goal of ultrasonic molecular imaging is the detection of targeted contrast agents bound to receptors on endothelial cells. We propose imaging methods that can distinguish adherent microbubbles...Full Text Available

2007-04-21

425

Radionuclide imaging of the acutely painful scrotum  

International Nuclear Information System (INIS)

This paper discusses the clinical application and main objective of testicular imaging. The authors present cases that represent a spectrum of the abnormalities which might be detected by testicular imaging, with special attention given to testicular torsion and the acute diseases which may mimic it clinically. Accuracy of the test is noted.

426

Quantifying the accuracy of automated structure segmentation in 4D CT images using a deformable image registration algorithm  

UK PubMed Central (United Kingdom)

Four-dimensional (4D) radiotherapy is the explicit inclusion of the temporal changes in anatomy during the imaging, planning, and delivery of radiotherapy. One key component of 4D radiotherapy planning...Full Text Available

2008-04-01

427

Performance evaluation of an automatic anatomy segmentation algorithm on repeat or four-dimensional CT images using a deformable image registration method  

UK PubMed Central (United Kingdom)

PurposeAuto-propagation of anatomical region-of-interests (ROIs) from the planning CT to daily CT is an essential step in image-guided adaptive radiotherapy. The...Full Text Available

2008-09-01

428

Nonnegative Factorization of Diffusion Tensor Images and Its Applications  

UK PubMed Central (United Kingdom)

This paper proposes a novel method for computing linear basis images from tensor-valued image data. As a generalization of the nonnegative matrix factorization, the proposed method aims to approximate...Full Text Available

2011-01-01

429

Near Infrared-Fluorescent and Magnetic Resonance Imaging Molecular Probe with High T1 Relaxivity for In Vivo Multimodal Imaging  

UK PubMed Central (United Kingdom)

A new gadolinium chelating NIR fluorescent molecular probe increases T1 relaxivity of water protons, facilitating combined optical and magnetic resonance imaging.

2010-06-07

430

MULTIMODALITY IMAGING: BEYOND PET/CT AND SPECT/CT  

UK PubMed Central (United Kingdom)

Multimodality imaging with PET/CT and SPECT/CT has become commonplace in clinical practice and in preclinical and basic medical research. Do other combinations of imaging modalities have a similar...Full Text Available

2009-09-01

431

Longitudinal assessment of lung cancer progression in the mouse using in vivo micro-CT imaging  

UK PubMed Central (United Kingdom)

Purpose: Small animal micro-CT imaging is being used increasingly in preclinical biomedical research to provide phenotypic descriptions of genomic models. Most of this imaging is coincident...Full Text Available

2010-09-01

432

Imaging of calcium transients in skeletal muscle fibers.  

UK PubMed Central (United Kingdom)

Epifluorescence images of Ca2+ transients elicited by electrical stimulation of single skeletal muscle fibers were studied with fast imaging techniques that take advantage of the large fluorescence...Full Text Available

1991-01-01

433

High speed optical coherence microscopy with autofocus adjustment and a miniaturized endoscopic imaging probe  

UK PubMed Central (United Kingdom)

Optical coherence microscopy (OCM) is a promising technique or high resolution cellular imaging in human tissues. An OCM system for high-speed en face cellular resolution imaging...Full Text Available

2010-03-01

434

Diagnostic radiology: An Anglo-American textbook of imaging  

Energy Technology Data Exchange (ETDEWEB)

This multiauthored text is aimed particularly toward the resident or registrar training in diagnostic radiology. This is a text book on the entire scope of diagnostic imaging. It includes techniques and imaging modalities of all the systems, head, face and neck. The book covers the entire gamut of diagnostic radiology.

1986-01-01

435

Diagnostic quality of low resolution images for tele-woundcare.  

UK PubMed Central (United Kingdom)

The use of digital wound images would allow remote consultation between patients, physicians, or other caregivers over the Internet. To evaluate the efficacy and validity of digital images for assessment...Full Text Available

1998-01-01

436

Comparative evaluation of similarity measures for the rigid registration of multi-modal head images  

Energy Technology Data Exchange (ETDEWEB)

Image registrations that are based on similarity measures simply adjust the parameters of an appropriate spatial transformation model until the similarity measure reaches an optimum. The numerous similarity measures that have been proposed in the past are differently sensitive to imaging modality, image content and differences in the image content, selection of the floating and target image, partial image overlap, etc. In this paper, we evaluate and compare 12 similarity measures for the rigid registration. To study the impact of different imaging modalities on the behavior of similarity measures, we have used 16 CT/MR and 6 PET/MR image pairs with known 'gold standard' registrations. The results for the PET/MR registration and for the registration of CT to both rectified and unrectified MR ...

2007-09-21

437

Compact Image Slicing Spectrometer (ISS) for hyperspectral fluorescence microscopy  

UK PubMed Central (United Kingdom)

An image slicing spectrometer (ISS) for microscopy applications is presented. Its principle is based on the redirecting of image zones by specially organized thin mirrors within a custom fabricated...Full Text Available

2009-07-20

438

CR portal imaging  

International Nuclear Information System (INIS)

In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In ...

1992-01-01

439

An Evaluation of a Computer Imaging Program to Prepare Women for Chemotherapy-related Alopecia  

UK PubMed Central (United Kingdom)

ObjectiveThis study was conducted to evaluate a computer-imaging program called HAAIR (Help with Adjustment to Alopecia by Image Recovery) that was developed to provide...Full Text Available

2010-07-01

440

Post-mortem fetal MRI: What do we learn from it?  

International Nuclear Information System (INIS)

Post-mortem magnetic resonance (MR) imaging is of increasing interest not only as an alternative to autopsy but as a research tool to aid the interpretation and diagnosis of in utero MR images. The information from the post-mortem MR has allowed the development of imaging sequences applicable to in utero imaging and neonatal imaging. It has established brain development during gestation and has provided data on this to which in utero MR can be compared. The detail available from the post-mortem images is such that brain development can be studied in a non-invasive manner, a permanent record on the normal and abnormal areas is available and a greater understanding of developmental abnormalities is possible.

2006-02-01

441

MR imaging in neuroborreliosis of the cervical spinal cord  

Energy Technology Data Exchange (ETDEWEB)

The central nervous system is involved in 10-20% of cases in Lyme disease. The neurological symptoms, time course of the disease and imaging findings are multifaceted. We report two patients with cervical radiculitis. Magnetic resonance imaging revealed strong enhancement of the cervical nerve roots on contrast-enhanced T1-weighted images. These imaging patterns of borrelia-associated radiculitis have not been reported before. Knowledge of these imaging features may help to diagnose neuroborreliosis, which presents with non-specific symptoms. (orig.)

2004-11-01

442

Future of X-ray phase imaging in medical imaging technology  

International Nuclear Information System (INIS)

Weakly absorbing materials, such as biological, soft tissues, can be imaged by generating contrast due to the phase shift of X-rays. In the past decade, several methods for X-ray phase imaging were proposed and demonstrated. The performance of X-ray phase imaging is attractive in the field of medical imaging technology, and its development for practical use is expected. Many methods, however, have been developed under the assumption of the use of synchrotron radiation, which is an obstacle to practical use. The method based on Talbot (-Lau) interferometry enables us to use a compact X-ray source, and its development is expected as a breakthrough for medical applications. (author)

2007-04-01

443

Typhoon Aere : Image of the Day - NASA Earth Observatory  

Science.gov (United States)

Aug 25, 2004 ... The Tropical Rainfall Measuring Mission or TRMM satellite provided this image of Typhoon Aere over the western Philippine Sea as it was ...

444

The importance of radiation quality for optimisation in radiology  

UK PubMed Central (United Kingdom)

Selection of the appropriate radiation quality is an important aspect of optimisation for every clinical imaging task in radiology, since it affects both image quality and patient dose. Spreadsheet...Full Text Available

445

The Use of Medical Images in Planning and Delivery of Radiation Therapy  

UK PubMed Central (United Kingdom)

Abstract The authors provide a survey of how images are used in radiation therapy to improve the precision of radiation therapy plans, and delivery of radiation treatment. In contrast...Full Text Available

1997-09-01

446

Portal localization images using computed radiography for high-energy electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

Portal localization images for high-energy electron beam therapy are necessary to confirm the treatment field by comparing them with a simulation image obtained before treatment or portal verification images after treatment. In this study, portal localization images were acquired using the computed radiography (CR) system and bremsstrahlung X-rays generated in the electron beam irradiations. All images obtained with phantom and the irradiations of in the electron energy of 8, 10, 12 and 15 MeV were feasible for clinical use. The CR system used in this study included general diagnostic imaging cassette and storage phosphor plate, but none of other special devices. The system can usually supply portal localization images, which maintains the quality assurance of high-energy electron beam therapy. (author)

2002-09-01

447

Method for the reduction of image content redundancy in large image databases  

Energy Technology Data Exchange (ETDEWEB)

A method of increasing information content for content-based image retrieval (CBIR) systems includes the steps of providing a CBIR database, the database having an index for a plurality of stored digital images using a plurality of feature vectors, the feature vectors corresponding to distinct descriptive characteristics of the images. A visual similarity parameter value is calculated based on a degree of visual similarity between features vectors of an incoming image being considered for entry into the database and feature vectors associated with a most similar of the stored images. Based on said visual similarity parameter value it is determined whether to store or how long to store the feature vectors associated with the incoming image in the database.

2010-03-02

448

JHK and 3.3um PAH Imaging of the Starburst Ring in the Type I Seyfert Galaxy NGC 7469  

Science.gov (United States)

Imaging of NGC 7469 in the J, H, & K bands shows that the starburst 'ring' is a tight inner

1993-01-01

449

Implementation of improved interactive image analysis at the Advanced Photon Source (APC) linac.  

Energy Technology Data Exchange (ETDEWEB)

An image-analysis system, based on commercially available data visualization software (IDL [1]), allows convenient interaction with image data while still providing calculated beam parameters at a rate of up to 2 Hz. Image data are transferred from the IOC to the workstation via EPICS [2] channel access. A custom EPICS record was created in order to overcome the channel access limit of 16k bytes per array. The user can conveniently calibrate optical transition radiation (OTR) and fluorescent screens, capture background images, acquire and average a series of images, and specify several other filtering and viewing options. The images can be saved in either IDL format or APS-standard format (SDDS [3]), allowing for rapid postprocessing of image data by numerous other software tools.

1998-09-11

450

Imaging subsurface using cross-correlation  

Energy Technology Data Exchange (ETDEWEB)

This paper presents two imaging methods by using cross correlation. The one method images the subsurface by cross-correlation of the observed data and partial derivative seismograms calculated for a guessed model. The other method images the interface by use of cross-correlation of the virtual sources and the back propagated wave fields calculated from the observed data. Experimental tests show that both methods image subsurface interfaces well even if the guessed model is different from the true one. These imaging methods are reverse time migration that we perform cross-correlation as an imaging condition and have an advantage, as compared to conventional waveform inversion method, that images subsurface structure without iterative perturbation of the assumed model. (author). 18 refs., 15 figs.

1997-12-31

451

Image Analysis and Computer Vision: 1996.  

Science.gov (United States)

... Title : Image Analysis and Computer Vision: 1996. ... bibliography,. Corporate Author : MARYLAND UNIV COLLEGE PARK COMPUTER VISION LAB. ...

1997-01-01

452

Histopathological Image Analysis: A Review  

UK PubMed Central (United Kingdom)

Over the past decade, dramatic increases in computational power and improvement in image analysis algorithms have allowed the development of powerful computer-assisted analytical approaches...Full Text Available

2009-01-01

453

Visualization of strong around motion calculated from the numerical simulation of Hyogo-ken Nanbu earthquake; Suchi simulation de miru Hyogoken nanbu jishin no kyoshindo  

Energy Technology Data Exchange (ETDEWEB)

Hyogo-ken Nanbu earthquake with a focus in the Akashi straits has given huge earthquake damages in and around Awaji Island and Kobe City in 1995. It is clear that the basement structure, which is steeply deepened at Kobe City from Rokko Mountains towards the coast, and the focus under this related closely to the local generation of strong ground motion. Generation process of the strong ground motion was discussed using 2D and 3D numerical simulation methods. The 3D pseudospectral method was used for the calculation. Space of 51.2km{times}25.6km{times}25.6km was selected for the calculation. This space was discretized with the lattice interval of 200m. Consequently, it was found that the basement structure with a steeply deepened basement, soft and weak geological structure thickly deposited on the basement, and earthquake faults running under the boundary of base rock and sediments related greatly to ...

1996-10-01

454

Validation of the 3D finite element transport theory code EVENT for shielding applications  

Energy Technology Data Exchange (ETDEWEB)

This paper is concerned with the validation of the 3D deterministic neutral-particle transport theory code EVENT for shielding applications. The code is based on the finite element-spherical harmonics (FE-P{sub N}) method which has been extensively developed over the last decade. A general multi-group, anisotropic scattering formalism enables the code to address realistic steady state and time dependent, multi-dimensional coupled neutron/gamma radiation transport problems involving high scattering and deep penetration alike. The powerful geometrical flexibility and competitive computational effort makes the code an attractive tool for shielding applications. In recognition of this, EVENT is currently in the process of being adopted by the UK nuclear industry. The theory behind EVENT is described and its numerical implementation is outlined. Numerical results obtained by the code are compared with predictions of the Monte Carlo code MCBEND and ...

2000-03-01

455

VIBA-LAB2: a virtual ion beam analysis laboratory software package incorporating elemental map simulations  

International Nuclear Information System (INIS)

The software package VIBA-lab1, which incorporates PIXE and RBS energy spectra simulation has now been extended to include the simulation of elemental maps from 3D structures. VIBA-lab1 allows the user to define a wide variety of experimental parameters, e.g. energy and species of incident ions, excitation and detection geometry, etc. When the relevant experimental parameters as well as target composition are defined, the program can then simulate the corresponding PIXE and RBS spectra. VIBA-LAB2 has been written with applications in nuclear microscopy in mind. A set of drag-and-drop tools has been incorporated to allow the user to define a three-dimensional sample object of mixed elemental composition. PIXE energy spectra simulations are then carried out on pixel-by-pixel basis and the corresponding intensity distributions or elemental maps can be computed. Several simulated intensity distributions for some ...

1999-09-02

456

The effects of spatially distributed ionisation sources on the temperature structure of HII region  

CERN Document Server

Spatially resolved studies of star forming regions show that the assumption of spherical geometry is not realistic in most cases, with a major complication posed by the gas being ionised by multiple non-centrally located stars or star clusters. We try to isolate the effects of multiple non-centrally located stars on the temperature and ionisation structure of HII regions, via the construction of 3D photoionisation models using the 3D Monte Carlo photoionisation code MOCASSIN. We find that the true temperature fluctuations due to the stellar distribution (as opposed to the large-scale temperature gradients due to other gas properties) are small in all cases and not a significant cause of error in metallicity studies. Strong emission lines from HII regions are often used to study the metallicity of star-forming regions. We compare integrated emission line spectra from our models and quantify any ...

2007-01-01

457

Surface Topography of 'Hotspot' Regions from a Single Cell SRF Cavity  

Energy Technology Data Exchange (ETDEWEB)

Performance of SRF cavities are limited by non-linear localized effects. The variation of local material characters between "hot" and "cold" spots is thus of intense interest. Such locations were identified in a BCP-etched large-grain single-cell cavity and removed for examination by high resolution electron microscopy (SEM), electron-back scattering diffraction microscopy (EBSD), optical microscopy, and 3D profilometry. Pits with clearly discernable crystal facets were observed in both "hotspot" and "coldspot" specimens. The pits were found in-grain, at bi-crystal boundaries, and on tri-crystal junctions. They are interpreted as etch pits induced by surface crystal defects (e.g. dislocations). All "coldspots" examined had qualitatively low density of etching pits or very shallow tri-crystal boundary junction. EBSD revealed the crystal structure surrounding the pits via crystal phase orientation mapping, while ...

2009-05-01

458

Sunyaev-Zeldovich profiles for clusters and groups of galaxies  

CERN Document Server

The Sunyaev-Zeldovich (SZ) effect gives a measure of the thermal energy and electron pressure in groups and clusters of galaxies. In the near future SZ surveys will map hundreds of systems, shedding light on the pressure distribution in the systems. The thermal energy is related to the total mass of a system of galaxies, but it is only a projection that is observed through the SZ effect. A model for the 3D distribution of pressure is needed to link the SZ signal to the total mass of the system. In this work we construct an empirical model for the 2D and 3D SZ profile, and compare it to a set of realistic high resolution SPH simulations of galaxy clusters and groups, and to a stacked SZ profile for massive clusters derived from WMAP data. Furthermore, we combine observed temperature profiles with dark matter potentials to yield an additional constraint, under the assumption of hydrostatic equilibrium. We ...

2007-01-01

459

Seismic tomography inversion in the case that sources and receivers are distributed out of a 2-D plane; Shingen jushinten ga nijigen heimennai ni nai baai no danseiha tomography kaiseki ni kansuru kosatsu  

Energy Technology Data Exchange (ETDEWEB)

In the case where sources and receivers are not distributed on a 2-D plane, seismic tomography inversion was studied. In tomography experiments, the existing wells are generally used. In such case, sources and receivers are frequently not distributed on a 2-D plane. The 2.5-D analysis method including 2-D structure and 3-D ray-tracing was thus developed. This method is featured by less memory necessary for ray-tracing calculation, and the same algorithm for velocity determination as 2-D analysis method. In previous methods, since analysis is generally carried out by projecting sources and receivers on a certain assumed 2-D plane, it can derive correct results in the case of constant velocity and straight ray, however, in the other case, it derives incorrect results. Application of 3-D tomography requires a large amount of memory, and falls into poor convergence because of various parameters. The 2.5-D ...

1996-10-01

460

Results of 3-dimensional structural FE-modeling of the coil end-regions of the LHC main dipoles  

CERN Document Server

The transition region between the straight part and the ends of the coils of the LHC model and prototype dipole magnets are often identified as the origin of training quenches. In order to study how the discontinuities in the material properties of these regions affect coil pre-stress and possibly gain more insight in the quench behavior, a program was set up at CERN to analyze by 3D-FEM these particular regions. The ACCEL team, who performed a similar analysis for the main quadrupoles of the Superconducting Supercollider SSC, is entrusted with this program. In this paper we report on the results of 3D-modeling and analysis of the coil return end region, including the complete coil mass, of a 1-m single bore model magnet. This magnet represents all relevant features of the "two-in-one" LHC main dipole design concerning the winding configuration, the collar pack, the yoke, and the outer shell ...

2000-01-01

461

Physically based modelling of damage, amorphization, and recrystallization for predictive device-size process simulation  

Energy Technology Data Exchange (ETDEWEB)

Current advanced CMOS source/drain engineering involves the use of amorphizing implants with 3D geometry. Upon annealing, the induced transient enhanced diffusion (TED) can only be accurately predicted if the amorphized region is correctly modeled, as well as the formation and evolution of extended defects, particularly 3 1 1's and dislocation loops. In addition to the extended defects, already modeled in the atomistic kinetic Monte-Carlo simulator DADOS, we have developed a physically based modeling approach for the implant-induced damage build-up, amorphization and recrystallization, suitable to handle device-size process simulation. It is based on amorphous pockets (3D, irregular shape agglomerates of an arbitrary number of interstitials and vacancies, plus trapped impurities) with a size-dependent activation energy for recombination. The model is able to reproduce experimental aspects like ...

2004-12-15

462

Physically based modelling of damage, amorphization, and recrystallization for predictive device-size process simulation  

International Nuclear Information System (INIS)

Current advanced CMOS source/drain engineering involves the use of amorphizing implants with 3D geometry. Upon annealing, the induced transient enhanced diffusion (TED) can only be accurately predicted if the amorphized region is correctly modeled, as well as the formation and evolution of extended defects, particularly 3 1 1's and dislocation loops. In addition to the extended defects, already modeled in the atomistic kinetic Monte-Carlo simulator DADOS, we have developed a physically based modeling approach for the implant-induced damage build-up, amorphization and recrystallization, suitable to handle device-size process simulation. It is based on amorphous pockets (3D, irregular shape agglomerates of an arbitrary number of interstitials and vacancies, plus trapped impurities) with a size-dependent activation energy for recombination. The model is able to reproduce experimental aspects like the ...

2004-12-15

463

Phenomenological 3D and 1D consistent models for shape-memory alloy materials  

Science.gov (United States)

The paper deals with the modeling and the development of a numerical procedure for the analysis of shape-memory alloy (SMA) elements in order to predict the main features of SMA devices. A 3D SMA model in the framework of small strain theory is developed starting from the thermo-mechanical model proposed by Souza et al. (Eur J Mech A/Solids 17:789-806, 1998) and modified by Auricchio and Petrini (Int J Numer Methods Eng 55:1255-1284, 2002). The aim of this paper is to propose some more modifications to the original model, to derive its consistent 1D formulation, to clarify the mechanical meaning of the material parameters governing the constitutive model. A robust time integration algorithm is developed in the framework of the finite element method and a new beam finite element is proposed. Some numerical applications and a comparison with experimental data available in literature are carried out in order to assess the ability of the proposed ...

2009-08-01

464

Numerical flow simulation in ship and ocean engineering; Senpaku kaiyo suiri bun`ta deno ryutai suchi simulation  

Energy Technology Data Exchange (ETDEWEB)

The improvement in the functions of the viscous flow calculation method VEGA-SHIP around a ship and the expansion of application range were described as the numerical flow simulation in ship and ocean engineering and at the same time application examples to the ocean engineering by the general-purpose flow simulation code FLOW-3D handling the non-steady flow with a free surface were introduced as the numerical simulation regarding such products as a water gate and a dam. In the VEGA-SHIP, water surface was handled as a fixed wall so that wave could not be calculated. Therefore, an algorithm for calculating wave on the water surface was added to the VEGA-SHIP and a calculation method simultaneously considering the creation of wave around the ship and viscosity was developed. The FLOW-3D was used to calculate the phenomenon where inside liquid moved greatly due to the oscillation of a tank and hit against ...

1995-01-01

465

NMR in highly correlated superconductors  

International Nuclear Information System (INIS)

Results of our systematic NMR study in high T_c cuprates are reviewed. The antiferromagnetic spin fluctuations (AFSF) decrease in the order of La_1_._8_5Sr_0_._1_5CuO_4. YBa_2Cu_3O_7 and Tl_2Ba_2CuO_6_+_y. 1/T_1 of "6"3Cu in the CuO_2 plane in the normal state follows essentially a Curie-Weiss law at high temperature and T_1T = const. law at low temperature. The temperature dependence of 1/T_1 and the Knight shift together with their impurity effect in the superconducting state strongly suggest d-wave pairing implying the AFSF to be responsible for the occurrence of superconductivity. From the NQR frequency measurement the density of Cu 3d and O 2p holes decreases and increases, respectively, in the order of La, Y and Tl compounds, which is consistent with the change of AFSF. The relation between T_c and #nu#_Q, and their pressure dependence suggest that there exists and optimum value of the ratio of Cu ...

1992-08-01

466

K{beta}-to-K{alpha} X-ray intensity ratio studies on the changes of valence electronic structures of Ti, V, Cr, and Co in their disilicide compounds  

Energy Technology Data Exchange (ETDEWEB)

K{beta}-to-K{alpha} X-ray intensity ratios of Ti, V, Cr, and Co in pure metals and their disilicide compounds have been measured following excitation by 59.54 keV {gamma}-rays from a 200 mCi {sup 241}Am point-source. The K{beta}-to-K{alpha} intensity ratios of all these metals in the disilicide compounds are found to be less than the corresponding ratios for pure metals. Comparison of the measured K{beta}-to-K{alpha} intensity ratios for the disilicides and pure metals with the multiconfiguration Dirac-Fock calculations indicates increase of the 3d electron populations of Ti, V, Cr, and Co in the disilicides from their pure metal values suggesting the rearrangement of electrons between 3d and 4s states of the individual metal atom. This rearrangement is found to be opposite to that observed in our previously reported work on NiSi{sub 2} and CuSi{sub 2}.

1999-06-01

467

K#beta#-to-K#alpha# X-ray intensity ratio studies on the changes of valence electronic structures of Ti, V, Cr, and Co in their disilicide compounds  

International Nuclear Information System (INIS)

K#beta#-to-K#alpha# X-ray intensity ratios of Ti, V, Cr, and Co in pure metals and their disilicide compounds have been measured following excitation by 59.54 keV #gamma#-rays from a 200 mCi "2"4"1Am point-source. The K#beta#-to-K#alpha# intensity ratios of all these metals in the disilicide compounds are found to be less than the corresponding ratios for pure metals. Comparison of the measured K#beta#-to-K#alpha# intensity ratios for the disilicides and pure metals with the multiconfiguration Dirac-Fock calculations indicates increase of the 3d electron populations of Ti, V, Cr, and Co in the disilicides from their pure metal values suggesting the rearrangement of electrons between 3d and 4s states of the individual metal atom. This rearrangement is found to be opposite to that observed in our previously reported work on NiSi_2 and CuSi_2.

1999-06-01

468

Investigation of local-dimensional galvanic distortion on MT data in the central part of Northeastern Japan; Tohoku chiho no MT data ni mirareru kyokushoteki sanjigensei no eikyo  

Energy Technology Data Exchange (ETDEWEB)

Groom-Bailey decomposition analysis was carried out to investigate regional 3-D galvanic distortion on MT data in the central part of Northeastern Japan. Measuring sites were located nearly along the east-west line crossing Northeastern Japan. Three measuring lines (A, B, C) from the north to the south were prepared, and only data on the C line were analyzed in this paper. As a result, twist and shear were estimated to be not zero depending on local distortion in most of the sites. It was thus clarified that this method is not always perfect. This method was effective for regional 2-D structures, however, its application was doubtful to complicated 3-D underground structures in Japan. In order to obtain more accurate results, 2-D analysis using the impedance including no local distortion effect was necessary after the preliminary Groom-Bailey decomposition analysis. The direction of the wide area ...

1996-10-01

469

Influence of Ce0.9Gd0.1O2-d particles on microstructure and oxygen permeability of Ba0.5Sr0.5Co0.8Fe0.2O3-d composite membrane  

British Library Electronic Table of Contents (United Kingdom)

This study examined the oxygen permeation behavior of Ce0.9Gd0.1O2-d (Gadolinium-Doped Ceria, GDC)/Ba0.5Sr0.5Co0.8Fe0.2O3-d (BSCF) composite membranes fabricated using a conventional sintering technique. GDC/BSCF composite membranes with a relative density >95% could be obtained when a green compact of BSCF and GDC was sintered at 1150^oC for 5h. It appears that GDC serves as a grain growth inhibitor because the average grain size of the composite decreased with increasing GDC content. The oxygen permeability of the BSCF and GDC/BSCF composite membranes strongly depends on the grain size and membrane thickness. The addition of GDC to BSCF resulted in a small grain size, low thermal expansion coefficient and high hardness. However, it is believed that oxygen permeation was blocked by GDC, a...

2010-01-01

470

Feasibility study of large combined function magnets for the Jefferson lab 12 GeV upgrade  

CERN Document Server

The 12 GeV upgrade at Jefferson Lab has identified two new large spectrometers as Physics detectors for the project. The first is a 7.5 Gev/c 35 m-sr. spectrometer that requires a pair of identical Combined Function Superconducting Magnets (CFSM) that can simultaneously produce 1.5 T dipole fields and 4.5 T/m quadrupole fields inside a warm bore of 120cm. The second is an 11 GeV/c 2 m-sr. spectrometer that requires a CFSM that simultaneously produces a dipole field of 4.0 T and a quadruple field of 3.0 T/m in a 60 cm warm bore. Magnetic designs using TOSCA 3D have been performed to realize the magnetic requirements, provide 3d fields for optics analysis and produce field and force information for the engineering feasibility of the magnets. A two-sector cos( theta )/cos(2 theta ) design with a low nominal current density, warm bore and warm iron design has been selected and analyzed. These low current ...

2005-01-01

471

Direct observation of ordered orbital of YTiO_3 by the X-ray magnetic diffraction technique  

International Nuclear Information System (INIS)

X-ray magnetic diffraction (XMD) technique was applied to an orbital ordering compound of ferromagnetic YTiO_3 for the first time. The orbital-magnetic form factor #mu# _L(k) and the spin-magnetic form factor #mu# _S(k) were independently measured by utilizing the LS separation ability of the XMD. The #mu# _L(k) was measured for ten reciprocal-lattice points. No significant values of the #mu# _L(k) were observed for most of the reciprocal-lattice points within the estimated statistical errors, which suggested quenching of the orbital moment. The #mu# _S(k) was measured for 22 reciprocal-lattice points. Fourier synthesis of the #mu# _S(k) gave the spin density distribution m _S(r) in the real space. The obtained m _S(r) map shows the characteristic feature of the electron distribution of 3d electron in the t_2_g state of a Ti atom coordinated by O"2"- ions, in which the electrons are distributed away from the negative O"2"- ions. It is concluded ...

2005-08-01

472

Decay of the Ar 2s"-"1 and 2p"-"1 and Kr 3p"-"1 and 3d"-"1 hole states studied by photoelectron-ion coincidence spectroscopy  

International Nuclear Information System (INIS)

The decay channels of the Ar 2s"-"1 and 2p"-"1 and Kr 3p"-"1 and 3d"-"1 electronic hole states have been investigated by means of photoelectron-photoion coincidence measurements following innershell ionization using synchrotron radiation. With the method of final ion-charge resolving electron spectroscopy it has become possible to disentangle different contributions to the electron spectrum and to determine the decay probabilities P(nl"-"1#->#n+) of the above-mentioned hole states (nl"-"1) to the final ionic charge states n+. A high correlation with threefold or even fourfold charged ions has been found in all cases. Possible decay routes, via cascade or direct double Auger processes, are discussed on the basis of energy-level schemes calculated with the Hartree-Fock method. Special emphasis is laid on the examination of the Kr 3p"-"1 decay process, where the two fine-structure components (j=1/2,3/2) exhibit noticeably different decay ...

2002-04-01

473

Computational models of stellar collapse and core-collapse supernovae  

International Nuclear Information System (INIS)

Core-collapse supernovae are among Nature's most energetic events. They mark the end of massive star evolution and pollute the interstellar medium with the life-enabling ashes of thermonuclear burning. Despite their importance for the evolution of galaxies and life in the universe, the details of the core-collapse supernova explosion mechanism remain in the dark and pose a daunting computational challenge. We outline the multi-dimensional, multi-scale, and multi-physics nature of the core-collapse supernova problem and discuss computational strategies and requirements for its solution. Specifically, we highlight the axisymmetric (2D) radiation-MHD code VULCAN/2D and present results obtained from the first full-2D angle-dependent neutrino radiation-hydrodynamics simulations of the post-core-bounce supernova evolution. We then go on to discuss the new code Zelmani which is based on the open-source HPC Cactus framework and provides a scalable AMR approach for ...

2009-07-01

474

Alloying effect on K to L shell vacancy transfer probabilities in 3d transition metals  

British Library Electronic Table of Contents (United Kingdom)

The alloying effects on K to L shell vacancy transfer probabilities (?KL) in 3d transition metals have been carried out by X-ray fluorescence studies of various alloy compositions. K X-ray intensity ratios of Ti, Cr, Fe, Co, Ni, and Cu elements in the FexNi1?x, FexCr1?x, NixCr1?x, FexCryNi1?(x+y), TixNi1?x, TixCo1?x, and CoxCu1?x alloys have been measured following excitation by 22.69keV X-rays from a 10 mCi 109Cd radioactive point source and ?KL values for alloying elements have been determined from these ratios. The spectrum of characteristic K-X-ray photons from samples were detected with a high resolution Si(Li) detector coupled to a 4 K multichannel analyzer. The present investigation makes it possible to ...

2010-01-01

475

A widely tunable continuous-time LPF for a direct conversion DBS tuner  

Energy Technology Data Exchange (ETDEWEB)

A continuous-time 7th-order Butterworth Gm-C low pass filter (LPF) with on-chip automatic tuning circuit has been implemented for a direct conversion DBS tuner in 0.35 mum SiGe BiCMOS technology. The filter's -3 dB cutoff frequency f{sub 0} can be tuned from 4 to 40 MHz. A novel on-chip automatic tuning scheme has been successfully realized to tune and lock the filter's cutoff frequency. Measurement results show that the filter has -0.5 dB passband gain, +-5% bandwidth accuracy, 30 nV/Hz{sup 1/2} input referred noise, -3 dBVrms passband IIP3, and 27 dBVrms stopband IIP3. The I/Q LPFs with the tuning circuit draw 13 mA (with f{sub 0} = 20 MHz) from 5 V supply, and occupy 0.5 mm{sup 2}.

2009-02-15

476

Universal spectrochemical series of six-coordinate octahedral metal complexes for modifying the ligand field splitting.  

Science.gov (United States)

We studied a novel universal spectrochemical series of six-coordinated octahedral 3d transition metal complexes, which can be used for any combination of central metal atom and ligand molecules. A two dimensional spectrochemical series could be used to estimate the ligand field splitting energy of not only known compounds but also the unknown compounds. Therefore, it should be possible to control the physical properties, such as the electronic and magnetic properties and the optical phenomena of octahedral transition metal complexes by modifying the ligand field splitting. PMID:19378561

2009-01-28

477

The entropic boundary law in BF theory  

International Nuclear Information System (INIS)

We compute the entropy of a closed bounded region of space for pure 3d Riemannian gravity formulated as a topological BF theory for the gauge group SU(2) and show its holographic behavior. More precisely, we consider a fixed graph embedded in space and study the flat connection spin network state without and with particle-like topological defects. We regularize and compute exactly the entanglement for a bipartite splitting of the graph and show it scales at leading order with the number of vertices on the boundary (or equivalently with the number of loops crossing the boundary). More generally these results apply to BF theory with any compact gauge group in any space-time dimension.

2009-01-11

478

Simulation of the transient eddy current measurement for the characterization of depth and conductivity of a plate  

International Nuclear Information System (INIS)

A transient eddy current measurement method is presented to determine the thickness and conductivity of a conductive plate. The conductive plate is induced by an air-cored coil, the magnetic flux density along the axial is measured and the various signals corresponding to plates with different thickness and conductivity are calculated using a 3D transient eddy current simulator. Characteristic features are obtained from the transient response. A similarity-based modeling method is utilized in this study to estimate the thickness and conductivity of the conductive plate. (author)

2008-07-01

479

Scaling and performance of a 3-D radiation hydrodynamics code on message-passing parallel computers: final report  

Energy Technology Data Exchange (ETDEWEB)

This report details an investigation into the efficacy of two approaches to solving the radiation diffusion equation within a radiation hydrodynamic simulation. Because leading-edge scientific computing platforms have evolved from large single-node vector processors to parallel aggregates containing tens to thousands of individual CPU's, the ability of an algorithm to maintain high compute efficiency when distributed over a large array of nodes is critically important. The viability of an algorithm thus hinges upon the tripartite question of numerical accuracy, total time to solution, and parallel efficiency.

1999-10-28

480

Results from the photoemission spectroscopy beamline 2B1 at Pohang Light Source  

Energy Technology Data Exchange (ETDEWEB)

The results of photoemission spectroscopy using molybdenum and tantalum samples have been obtained from the new beamline 2B1 at Pohang Light Source. Beamline 2B1 is based on a spherical grating monochromator (SGM) which is equipped with five gratings. The photon energy range from 184 to 1100 eV was covered in this work using two gratings (Gratings 4 and 5). The photon energy resolution has been deduced from Ta Fermi-level spectra and 3d spectra of Mo.

1999-06-01

481

Report of the Fluid Dynamics Panel Working Group 10 on calculation of 3D separate turbulent flows in boundary layer limit  

Science.gov (United States)

The results of a study conducted by Working Group 10 of the AGARD Fluid Dynamics Panel to investigate the limits of boundary layer methods, both the integral and field type formulations, for calculating three-dimensional turbulent separated flow are presented. Test cases used to assess the boundary layer calculations included the DFLVR prolate spheroid at angle of attack and the NASA-Ames Wing C. Comparisons between boundary layer calculations and experimental data are presented for these test cases along with observations, conclusions, and recommendations.

1990-05-01

482

Modified-VSIMM algorithm with an application to the naval fire control technology  

British Library Electronic Table of Contents (United Kingdom)

A modified variable structure interacting multiple model (M-VSIMM) estimator for complex hybrid maneuver target tracking is presented. The M-VSIMM could potentially be applied to fire control systems (FCS) used on warships. Target model groups were designed using 3D dimensional dynamic target models. Optimal model group selection logic was proposed, contrary to the activation and termination logic in the original VSIMM. The system will respond faster with optimal model group selection logic. After performing simulations, the tracking performances of the Kalman, ?-?(-?), VDIE, IMM and M-VSIMM filters were compared under various maneuvering conditions.

2011-01-01

483

Modelling of Aquitaine II pipe whipping test with the EUROPLEXUS fast dynamics code  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a numerical simulation with the EUROPLEXUS fast dynamics software of a pipe whipping phenomenon occurring in the thermal hydraulic conditions of a loss of coolant accident in a PWR primary circuit. Different physical phenomena take place simultaneously during the rupture and the whipping of the pipe such as plasticity, contact, large displacements, two-phase flow regime and fluid structure interaction. Two kinds of numerical models - a simplified pipeline model and a mixed 1D/3D model - are considered and compared throughout modelling and computation. Numerical results are compared with experimental data belonging to the Aquitaine II test campaign.

2005-08-01

484

Modeling global atmospheric CO2 with improved emission inventories and CO2 production from the oxidation of other carbon species  

Energy Technology Data Exchange (ETDEWEB)

The use of global three-dimensional (3-D) models with satellite observations of CO2 in inverse modeling studies is an area of growing importance for understanding Earth s carbon cycle. Here we use the GEOS-Chem model (version 8-02-01) CO2 mode with multiple modifications in order to assess their impact on CO2 forward simulations. Modifications include CO2 surface emissions from shipping (0.19 PgC yr 1), 3-D spatially-distributed emissions from aviation (0.16 PgC yr 1), and 3-D chemical production of CO2 (1.05 PgC yr 1). Although CO2 chemical production from the oxidation of CO, CH4 and other carbon gases is recognized as an important contribution to global CO2, it is typically accounted for by conversion from its precursors at the surface rather than in the free troposphere. We base our model 3-D spatial distribution of ...

2010-01-01

485

Ion Transport Measurements in a Multi-Dipole Argon Plasma by Broadband Laser Induced Fluorescence  

International Nuclear Information System (INIS)

Argon ion laser induced fluorescence measurements were carried out in a multipolar filament discharge with a broadband diode laser centered on 668 nm, which stimulated a transition from the metastable state in Ar(II) 3d4F7/2 to 4p4D05/2. The intensity of the induced fluorescence at 442 nm was maximized by the optimization of the discharge parameters and the laser power. From the recovery of the background fluorescence after the laser was turned off, the ion diffusion coefficient was deduced and compared with the result inferred from the experiments of ion acoustic wave (IAW) damping.

2009-06-01

486

Investigation of Two-Phase Flow Regime Maps for Development of Thermal-Hydraulic Analysis Codes  

Energy Technology Data Exchange (ETDEWEB)

This reports is a literature survey on models and correlations for determining flow pattern that are used to simulate thermal-hydraulics in nuclear reactors. Determination of flow patterns are a basis for obtaining physical values of wall/interfacial friction, wall/interfacial heat transfer, and droplet entrainment/de-entrainment. Not only existing system codes, such as RELAP5-3D, TRAC-M, MARS, TRACE, CATHARE) but also up-to-date researches were reviewed to find models and correlations

2010-04-15

487

Formation and stability of self-assembled coherent islands in highly mismatched heteroepitaxy  

CERN Document Server

We study the energetics of island formation in Stranski-Krastanow growth within a parameter-free approach. It is shown that an optimum island size exists for a given coverage and island density if changes in the wetting layer morphology after the 3D transition are properly taken into account. Our approach reproduces well the experimental island size dependence on coverage, and indicates that the critical layer thickness depends on growth conditions. The present study provides a new explanation for the (frequently found) rather narrow size distribution of self-assembled coherent islands.

1999-01-01

488

Development of a chemically assisted micro-beam etching system for three-dimensional microanalysis  

Energy Technology Data Exchange (ETDEWEB)

A chemically assisted micro-beam etching system for 3D microanalysis was designed. Using chemically assisted ion beam etching (CAIBE) method with FIB shave-off scanning, about several hundred micrometers clean cross-section will be acquired in a few hours. We use focused ion beam (FIB) and electron beam (EB) as micro-beams, halogen or halide mainly as reactive gases. The apparatus was manufactured based on this concept. We found that the FIB, Q-MS and SED worked as expected. The instrumentation has been completed.

2003-01-15

489

Determination of the Venezuelan coastal-zone wind atlas by using numerical methods  

Energy Technology Data Exchange (ETDEWEB)

This work deals with the development of wind maps in the Venezuelan coastal zones (South America). The Navier-Stokes equations for real viscous incompressible flow are discretized via the finite element method and they are applied to a full 3D numerical model. Two regions were analyzed: the Margarita island and the Paraguana peninsula, both of them located in the Caribbean Sea at the North of Venezuela. These regions were modeled by using a three dimensional control volume, discretized through hexaedric eight-noded finite elements. Some wind maps obtained in this research are presented and discussed. (author)

1995-12-31

490

Design and Testing of Superconducting Microwave Passive Components for Quantum Information Processing  

CERN Document Server

We report on the design, fabrication and testing of two superconducting passive microwave components, a quadrature hybrid and a 20 dB directional coupler. These components are designed to be integrated with superconducting qubits or Josephson parametric amplifiers and used in quantum information processing applications. For the coupler, we measure return loss and isolation > 20 dB, and insertion loss 20 dB and insertion loss < 0.3 dB in a 10% band around 6.5 GHz. These values are within the design specifications of our application; however, we find a 7% difference between the designed and measured center frequency for the hybrid.

2010-01-01

491

Billion particle linac simulations for future light sources  

Energy Technology Data Exchange (ETDEWEB)

In this paper we report on multi-physics, multi-billion macroparticle simulation of beam transport in a free electron laser (FEL) linac for future light source applications. The simulation includes a self-consistent calculation of 3D space-charge effects, short-range geometry wakefields, longitudinal coherent synchrotron radiation (CSR) wakefields, and detailed modeling of RF acceleration and focusing. We discuss the need for and the challenges associated with such large-scale simulation. Applications to the study of the microbunching instability in an FEL linac are also presented.

2008-09-25

492

A spatial damage energy distribution calculation for ion-implanted materials  

International Nuclear Information System (INIS)

A simple method allowing easy calculation of the spatial damage energy distributions for ion-implanted materials is presented. The direct procedure takes account of the variation with depth of the lateral spreading of implanted ions, as well as the effects of energy transport by the recoiling target atoms. The subsequent computer program LUPIN-3D provides three-dimensional damage distributions and allows the construction of damage energy mappings. Various substrates of technological interest are investigated and several fields of application of the calculation are envisaged. The density of cascades can therefore be determined and heterogeneous amorphization models can be implemented. (orig.).

1989-01-01

493

A new technique for radon measurement based on a combination of a track-etch detector and activated charcoal  

Energy Technology Data Exchange (ETDEWEB)

A new technique for radon measurement in the natural environment was investigated. It is based on the use of activated charcoal and a track-etch detector. The charcoal acts as a radon collector from the air and the track-etch detector as a recorder of the alpha particles emitted by radon and its decay products. Our preliminary results show that the response of the new dosimeter to radon, using Deodorant activated charcoal (TOK, Yugoslavia) and a CR-39 track-etch detector, is 1.4 tracks cm{sup -2}/Bqm{sup -3}d, which is about eight times higher than that obtained with a standard track-etch dosimeter. (author).

1991-01-01

494

A Preliminary Analysis of SMART Reactor Core Using the COREDAX Code  

International Nuclear Information System (INIS)

The 3-D neutronics code COREDAX has been developed based on AFEN (Analytic Function Expansion Nodal) method for x-y-z geometry and for hex-z geometry. In this study, the COREDAX code, as a regulatory review tool independent of the designer's, was applied to the SMART reactor core that was designed by KAERI (Korea Atomic Energy Research Institute). For nuclear cross section generation, the HELIOS lattice code was used in this study. The preliminary results for steady state in various conditions are presented in this paper

2010-10-01

495

Validity and sensitivity of a model for assessment of impacts of river floodplain reconstruction on protected and endangered species  

International Nuclear Information System (INIS)

Environmental Impact Assessment (EIA) must account for legally protected and endangered species. Uncertainties relating to the validity and sensitivity of EIA arise from predictions and valuation of effects on these species. This paper presents a validity and sensitivity analysis of a model (BIO-SAFE) for assessment of impacts of land use changes and physical reconstruction measures on legally protected and endangered river species. The assessment is based on links between species (higher plants, birds, mammals, reptiles and amphibians, butterflies and dragon- and damselflies) and ecotopes (landscape ecological units, e.g., river dune, soft wood alluvial forests), and on value assignment to protected and endangered species using different valuation criteria (i.e., EU Habitats and Birds directive, Conventions of Bern and Bonn and Red Lists). The validity of BIO-SAFE has been tested by comparing predicted effects of landscape changes on the diversity of protected and ...

2006-11-01

496

Quantitative spectroscopy of close binary stars  

CERN Document Server

The method of spectral disentangling has now created the opportunity for studying the chemical composition in previously inaccessible components of binary and multiple stars. This in turn makes it possible to trace their chemical evolution, a vital aspect in understanding the evolution of stellar systems. We review different ways to reconstruct individual spectra from eclipsing and non-eclipsing systems, and then concentrate on some recent applications to detached binaries with high-mass and intermediate-mass stars, and Algol-type mass-transfer systems.

2011-01-01

497

Quantitative evaluation of simultaneous reconstruction with model-based crosstalk compensation for 99mTc?123I dual-isotope simultaneous acquisition brain SPECT  

UK PubMed Central (United Kingdom)

A model-based method has been previously developed to estimate and compensate for the crosstalk and downscatter contamination in simultaneous 123I∕99mTc dual-isotope SPECT...Full Text Available

2009-06-01

498

Correlations between D and Dbar mesons in high energy photoproduction  

Energy Technology Data Exchange (ETDEWEB)

Over 7000 events containing a fully reconstructed D{bar D} pair have been extracted from data recorded by the FOCUS photoproduction experiment at Fermilab. Preliminary results from a study of correlations between D and {bar D} mesons are presented. Correlations are used to study perturbative QCD predictions and investigate non-perturbative effects. We also present a preliminary result on the production of {psi}(3770).

2002-11-13

499

Computed tomography - old ideas and new technology  

International Nuclear Information System (INIS)

Several recently introduced 'new' techniques in computed tomography - iterative reconstruction, gated cardiac CT, multiple-source, and dual-energy CT - actually date back to the early days of CT. We review the historic origins and evolution of these techniques, which may provide some insight into the latest innovations in commercial CT systems. (orig.)

2011-03-01

500

A Search for electron neutrino appearance at the Delta m**2 ~ 1- eV**2 scale  

Energy Technology Data Exchange (ETDEWEB)

The MiniBooNE Collaboration reports first results of a search for {upsilon}{sub e} appearance in a {upsilon}{sub {mu}} beam. With two largely independent analyses, we observe no significant excess of events above background for reconstructed neutrino energies above 475 MeV. The data are consistent with no oscillations within a two neutrino appearance-only oscillation model.

2007-04-01