Cementless bipolar hemiarthroplasty in femoral neck fractures in elderly  

UK PubMed Central (United Kingdom)

Background:Cemented hip arthroplasty is an established treatment for femoral neck fracture in the mobile elderly. Cement pressurization raises intramedullary pressure and...Full Text Available

2011-05-01

4

A cementless elastic monoblock socket in young patients: a ten to 18-year clinical and radiological follow-up  

British Library Electronic Table of Contents (United Kingdom)

The survival of acetabular components depends on several factors: wear, osteolysis and septic or aseptic loosening. Osteolysis seems to be the main cause for concern in cementless arthroplasties. Acetabular osteolysis results from particle debris and segmental unloading of acetabular bone by rigid sockets. We investigated a cementless elastic monoblock socket with regard to acetabular osteolysis and aseptic loosening in a cohort of young patients. We evaluated 158 hip arthroplasties with a minimum follow-up of ten?years (ten to 18) and a mean age of 42?years (18?50). The overall revision rate at 14?years was 80% with a 98% survival rate for aseptic loosening. The mean polyethylene wear rate was 0.11?mm/year. Progressive acetabular osteolysis was seen in 3% of patients evaluated. In conclus...

2011-01-01

5

Case Reports: Fractures of Threaded Cups: Rare Complications of a Well-established Implant  

UK PubMed Central (United Kingdom)

The use of cementless threaded cups in THA is a well-established treatment. Fractures of the cups are rare complications recorded in individual cases with material defects being discussed as the primary...Full Text Available

2009-03-01

6

Development and application of a diaphragm micro-pump with piezoelectric device  

British Library Electronic Table of Contents (United Kingdom)

In this study, a new type of thin, compact, and light weighed diaphragm micro-pump has been successfully developed to actuate liquid by the vibration of a diaphragm. The micro-diaphragm pump with two valves is fabricated in an aluminum case by using highly accurate CNC machine, and the cross-section dimension is 28?mm??5?mm. Both valves and diaphragm are manufactured from PDMS. The amplitude of vibration by a piezoelectric device produces an oscillating flow and alters the chamber volume by the curvature change of a diaphragm. Several experimental set-ups for performance tests in a single micro-diaphragm pump, isothermal flow open system, and a closed liquid cooling system are designed and implemented. The performance of a one-side actuating micro-diaphragm pump is affected by the design ...