WorldWideScience
1

Measurements and evaluations of nuclear data on actinide isotopes  

International Nuclear Information System (INIS)

The measurements of the nuclear decay of actinide isotopes and the evaluation of the radioactive properties of nuclide with the mass 242 is discussed in this paper.

1979-08-01

2

Using neutron-activation detectors with fissionable nuclides  

Energy Technology Data Exchange (ETDEWEB)

Presented are results of a test of a method for measuring neutron fluences using detectors with fissionable nuclides. The investigations show the soundness of of using neutron-activation detectors of the type Am for mesurements in nuclear installations for values of thermal-neutron fluence of from 10/sup 13/ to 10/sup 20/ neutrons/cm/sup 2/ with exposure for up to several months. The proposed method can be used for prolonged measurements in strong fields of both thermal and fast neutrons.

1986-09-01

3

First direct mass measurement of the proton rich nuclides {sup 85,86,87}Mo and {sup 87}Tc  

Energy Technology Data Exchange (ETDEWEB)

The masses of proton rich nuclides in the vicinity of N=Z=43 were measured with the Penning trap mass spectrometer SHIPTRAP at GSI. These nuclei were produced in the fusion-evaporation reaction {sup 36}Ar+{sup 54}Fe at energies of 5.0 and 5.9 MeV/u and separated at the velocity filter SHIP. The data are of astrophysical interest since these nuclei are believed to be a part of the rp and {nu}p process paths. The masses of {sup 85}Mo and {sup 87}Tc were measured for the first time. The masses of another two nuclides, {sup 86,87}Mo, were determined for the first time in a direct mass measurement. For these nuclides the mass excess deviates from values of the 2003 Atomic Mass Evaluation by up to 1.5 MeV, indicating a systematic shift of the mass surface in this region of the nuclear chart. Additionally, the masses of {sup 86}Zr and {sup 85}Nb were ...

2009-07-01

4

First direct mass measurement of the proton rich nuclides "8"5","8"6","8"7Mo and "8"7Tc  

International Nuclear Information System (INIS)

The masses of proton rich nuclides in the vicinity of N=Z=43 were measured with the Penning trap mass spectrometer SHIPTRAP at GSI. These nuclei were produced in the fusion-evaporation reaction "3"6Ar+"5"4Fe at energies of 5.0 and 5.9 MeV/u and separated at the velocity filter SHIP. The data are of astrophysical interest since these nuclei are believed to be a part of the rp and #nu#p process paths. The masses of "8"5Mo and "8"7Tc were measured for the first time. The masses of another two nuclides, "8"6","8"7Mo, were determined for the first time in a direct mass measurement. For these nuclides the mass excess deviates from values of the 2003 Atomic Mass Evaluation by up to 1.5 MeV, indicating a systematic shift of the mass surface in this region of the nuclear chart. Additionally, the masses of "8"6Zr and "8"5Nb were measured and found to ...

2009-03-16

5

The decay of a new nuclide: "7"1Br  

International Nuclear Information System (INIS)

The decay of mass-separated samples of the previously unknown nuclide "7"1Br have been investigated by means of the Chalk River on-line isotope separator. Eleven #gamma#-transitions were assigned to the decay of this nuclide and its half-life was measured to be 21.4 +- 0.6 s. A simple decay scheme for "7"1Br has been constructed incorporating six levels in its daughter, "7"1Se. The half-life of the first excited state in "7"1Se was measured to be 5.5 +- 1.0 #mu#s and the transition from this state to the ground state was found to be highly converted. Systematic trends in the level schemes of "6"7Zn, "6"9Ge and "7"1Se are investigated. (orig.).

1981-07-20

6

Application od scaling technique for estimation of radionuclide inventory in radioactive waste  

International Nuclear Information System (INIS)

Safety studies related to the disposal of low- and intermediate waste indicate that the long term risk is determined by the presence of long-lived nuclides such as "1"4C, "5"9Ni, "6"3Ni, "9"9Tc, "1"2"9I and the transuranium elements. As most of these nuclides are difficult to measure, the correlation between these critical nuclides and some other easily measurable key nuclides such as "6"0Co and "1"3"7Cs has been investigated for typical waste streams of Paks Nuclear Power Plant (Hungary) and scaling factors have been proposed. An automated gamma-scanning monitor has been purchased and calibrated to determine the gamma-emitting radionuclides. Radiochemical methods have been developed to determine significant difficult-to-measure radionuclides. The radionuclides of interest have been "3H, "1"4C, "9"0Sr, "5"5Fe, "5"9Ni, "9"9Tc, "1"2"9I and ...

1996-09-16

7

Total and spontaneous fission half-lives for uranium, plutonium, americium and curium nuclides  

Energy Technology Data Exchange (ETDEWEB)

Measurements of the half-lives of some long-lived nuclides of elements Z = 92, 94, 95 and 96 have been compiled and evaluated. Recommended values are presented for {sup 232-236,238}U, for {sup 236,238-242,244}Pu, for {sup 241,242m,243}Am, and for {sup 242-248,250}Cm. Values are presented for both spontaneous fission half-life and total half-life. Problems with reported uncertainties are also discussed. (author).

1989-01-01

8

Inventory determination of low and intermediate level radioactive waste of Paks Nuclear Power Plant origin  

International Nuclear Information System (INIS)

In the execution of disposal of low and intermediate level radioactive wastes, it is important to evaluate accurately the kind and quantity of each radionuclide in the wastes. For such an evaluation, correlation of non-gamma-emitting nuclides based on gamma-emitting nuclides is recommended and regarded as a partial method. This method necessitates a completion of a highly accurate and reliable nondestructive assay system of gamma-emitting nuclides for partical use. In 1992, in support of the new waste disposal program in Hungary, Paks NPP initiated a waste characterization program to determine the radiological properties of its rad wastes. A segmented gamma scanning system has been set up to measure the gamma-emitting nuclides in 2000 litre low level drums following in-drum compaction. In the framework of the program a radiochemical analysis sub-program was stated to determine the ...

9

Modification of SGS system for application to various sized drums  

Energy Technology Data Exchange (ETDEWEB)

To dispose the radioactive waste drums, the waste form's integrity and the nuclides inventories must be assured according to the national and site waste acceptance criteria. Because they might be would gravely affected the performance objectives of disposal site. Our national regulation for the waste inventory related to 'Radioactive Waste Acceptance Criteria' requires that the activities of 13 nuclides and gross {alpha} must be measured and the 95 % of nuclides incorporated in the drum must be identified. It is very difficult to measure the radioactivity with accuracy from the regulated waste drum(200L), and have a large error in the analysis results. In present, there are two system, SGS (Segmented Gamma Scanning System) and TGS (Tomographic Gamma Scanning System) for the analysis of radionuclides from the waste drums. In general, it is known that the ...

2005-11-15

10

Modification of SGS system for application to various sized drums  

International Nuclear Information System (INIS)

To dispose the radioactive waste drums, the waste form's integrity and the nuclides inventories must be assured according to the national and site waste acceptance criteria. Because they might be would gravely affected the performance objectives of disposal site. Our national regulation for the waste inventory related to 'Radioactive Waste Acceptance Criteria' requires that the activities of 13 nuclides and gross #alpha# must be measured and the 95 % of nuclides incorporated in the drum must be identified. It is very difficult to measure the radioactivity with accuracy from the regulated waste drum(200L), and have a large error in the analysis results. In present, there are two system, SGS (Segmented Gamma Scanning System) and TGS (Tomographic Gamma Scanning System) for the analysis of radionuclides from the waste drums. In general, it is known that the accuracy of TGS is below 20 % ...

2005-11-01

11

New neutron-rich isotopes in the scandium-to-nickel region, produced by fragmentation of a 500 MeV/u sup 86 Kr beam  

Energy Technology Data Exchange (ETDEWEB)

We have measured production cross-sections of the new neutron-rich isotopes {sup 58}Ti, {sup 61}V, {sup 63}Cr, {sup 66}Mn, {sup 69}Fe, {sup 71}Co and neighbouring isotopes that have been identified as projectile fragments from reactions between a 500 MeV/u {sup 86}Kr beam and a beryllium target. The isotope identification was performed with the zero-degree magnetic spectrometer FRS at GSI, using in addition time-of-flight and energy-loss measurements. The experimental production cross-sections for the new nuclides and neighbouring isotopes are compared with an empirical parametrization. The resulting prospects for reaching even more neutronrich isotopes, such as the doubly-magic nuclide {sup 78}Ni, are discussed. (orig.).

1992-07-01

12

New neutron-rich isotopes in the scandium-to-nickel region, produced by fragmentation of a 500 MeV/u "8"6Kr beam  

International Nuclear Information System (INIS)

We have measured production cross-sections of the new neutron-rich isotopes "5"8Ti, "6"1V, "6"3Cr, "6"6Mn, "6"9Fe, "7"1Co and neighbouring isotopes that have been identified as projectile fragments from reactions between a 500 MeV/u "8"6Kr beam and a beryllium target. The isotope identification was performed with the zero-degree magnetic spectrometer FRS at GSI, using in addition time-of-flight and energy-loss measurements. The experimental production cross-sections for the new nuclides and neighbouring isotopes are compared with an empirical parametrization. The resulting prospects for reaching even more neutronrich isotopes, such as the doubly-magic nuclide "7"8Ni, are discussed. (orig.).

13

Decay of Neutron-Rich Mn Nuclides and Deformation of Heavy Fe Isotopes  

Energy Technology Data Exchange (ETDEWEB)

The use of chemically selective laser ionization combined with {beta} -delayed neutron counting at CERN/ISOLDE has permitted identification and half-life measurements for 623-ms {sup 61}Mn up through 14-ms {sup 69}Mn . The measured half-lives are found to be significantly longer near N=40 than the values calculated with a quasiparticle random-phase-approximation shell model. Gamma-ray singles and coincidence spectroscopy has been performed for {sup 64,66}Mn decays to levels of {sup 64,66}Fe , revealing a significant drop in the energy of the first 2{sup +} state in these nuclides that suggests an unanticipated increase in collectivity near N=40 . {copyright} {ital 1999} {ital The American Physical Society }

1999-02-01

14

Decay of Neutron-Rich Mn Nuclides and Deformation of Heavy Fe Isotopes  

International Nuclear Information System (INIS)

The use of chemically selective laser ionization combined with #beta# -delayed neutron counting at CERN/ISOLDE has permitted identification and half-life measurements for 623-ms "6"1Mn up through 14-ms "6"9Mn . The measured half-lives are found to be significantly longer near N=40 than the values calculated with a quasiparticle random-phase-approximation shell model. Gamma-ray singles and coincidence spectroscopy has been performed for "6"4","6"6Mn decays to levels of "6"4","6"6Fe , revealing a significant drop in the energy of the first 2"+ state in these nuclides that suggests an unanticipated increase in collectivity near N=40 . copyright 1999 The American Physical Society.

1999-02-01

15

Total and spontaneous fission half-lives for uranium, plutonium, americium and curium nuclides  

International Nuclear Information System (INIS)

Measurements of the half-lives of some long-lived nuclides of elements Z = 92, 94, 95 and 96 have been compiled and evaluated. Recommended values are presented for "2"3"2"-"2"3"6","2"3"8U, for "2"3"6","2"3"8"-"2"4"2","2"4"4Pu, for "2"4"1","2"4"2"m","2"4"3Am, and for "2"4"2"-"2"4"8","2"5"0Cm. Values are presented for both spontaneous fission half-life and total half-life. Problems with reported uncertainties are also discussed. (author).

16

The JEF2 fission product yield evaluation  

International Nuclear Information System (INIS)

A new evaluation (UKFY2) has been prepared of the independent and cumulative yields of the products of fission induced by thermal, fast, and 14 MeV neutrons in nuclides important for reactor design and operation and for fuel and waste management. Three spontaneously fissioning nuclides were also considered. The evaluation used a database that is considered to be complete up to early 1989. Careful study was made of experimental uncertainties and discrepancies, emphasizing the need for further measurements. Gaps in the data were filled by interpolation and extrapolation, using fits to empirical models. The yields were subsequently adjusted to fit physical constraints of the fissioning process. This paper describes the evaluation, which was submitted and accepted for inclusion in the JEF2 file. The file was produced in January 1990 and a revision of cumulative yield uncertainties distributed in January 1991.

17

Prompt neutron multiplicities for the transplutonium nuclides  

Science.gov (United States)

The direct determination of the average prompt neutron emission values is reviewed, and a method of comparing different sites of neutron emission multiplicity distribution values is described. Measured and recommended values are tabulated for these nuclides: /sup 241/Am, /sup 242/Am, /sup 242/Cm, /sup 243/Cm, /sup 244/Cm, /sup 246/Cm, /sup 247/Cm, /sup 248/Cm, /sup 250/Cm, /sup 245/Cm, /sup 249/Bk, /sup 246/Cf, /sup 249/Cf, /sup 250/Cf, /sup 252/Cf, /sup 254/Cf, /sup 251/Cf, /sup 253/Es, /sup 254/Es, /sup 244/Fm, /sup 246/Fm, /sup 255/Fm, /sup 252/No, /sup 254/Fm, /sup 256/Fm, /sup 257/Fm. 59 refs., 24 tabs. (LEW)

1985-01-01

18

New neutron-rich isotopes in the scandium-to-nickel region, produced by fragmentation of a 500 MeV/u {sup 86}Kr beam  

Energy Technology Data Exchange (ETDEWEB)

We have measured production cross-sections of the new neutron-rich isotopes {sup 58}Ti, {sup 61}V, {sup 63}Cr, {sup 66}Mn, {sup 69}Fe, {sup 71}Co and neighbouring isotopes that have been identified as projectile fragments from reactions between a 500 MeV/u {sup 86}Kr beam and a beryllium target. The isotope identification was performed with the zero-degree magnetic spectrometer FRS at GSI, using in addition time-of-flight and energy-loss mesurements. The experimental production cross-sections for the new nuclides and neighbouring isotopes are compared with an empirical parameterization. The resulting prospects for reaching even more neutron-rich isotopes, such as the doubly-magic nuclide {sup 78}Ni, are discussed. (orig.).

1991-10-01

19

Decay of very neutron-rich Mn nuclides and vanishing of the N=40 subshell closure in {sup 66}Fe  

Science.gov (United States)

The use of chemically selective laser ionization combined with beta-delayed neutron counting at ISOLDE has permitted identification and half-life measurements for {sup 61}Mn up through {sup 69}Mn. The 14(4)-ms half life for {sup 69}Mn is one of the shortest determined for any nuclide beyond the sd shell. Gamma-ray singles and coincidence spectra have been determined for the decays of {sup 64,66}Mn to levels of {sup 64,66}Fe, revealing strong deformation and vanishing of the N=40 subshell in the Fe isotopes. {copyright} {ital 1998 American Institute of Physics.}

1998-12-01

20

Decay of very neutron-rich Mn nuclides and vanishing of the N=40 subshell closure in "6"6Fe  

International Nuclear Information System (INIS)

The use of chemically selective laser ionization combined with beta-delayed neutron counting at ISOLDE has permitted identification and half-life measurements for "6"1Mn up through "6"9Mn. The 14(4)-ms half life for "6"9Mn is one of the shortest determined for any nuclide beyond the sd shell. Gamma-ray singles and coincidence spectra have been determined for the decays of "6"4","6"6Mn to levels of "6"4","6"6Fe, revealing strong deformation and vanishing of the N=40 subshell in the Fe isotopes.

1998-12-21

21

Mass measurements of the proton-rich nuclides {sup 85,86,87}Mo and {sup 87}Tc and their impact on the rp-process  

Energy Technology Data Exchange (ETDEWEB)

The masses of the proton-rich nuclides {sup 85,86,87}Mo and {sup 87}Tc have been measured with the Penning trap mass spectrometer SHIPTRAP at GSI. The measured mass excesses of these nuclei deviate from the values of the Atomic Mass Evaluation 2003 by up to 1.6 MeV, indicating a systematic shift of the mass surface in this region compared to previous measurements. A local mass extrapolation based on the new results has been made for the mass range A=80-95. Measured and extrapolated mass values and the derived separation energies have been compared to theoretical mass models. Taking into account the new mass excess values, rp-process network calculations have been performed. Preliminary results show changes in the final abundances for A=86-92 by up to a factor of 30. Results of measurements and calculations are presented, and the issue of a potential Zr-Nb cycle ...

2010-07-01

22

Mass measurements of the proton-rich nuclides "8"5","8"6","8"7Mo and "8"7Tc and their impact on the rp-process  

International Nuclear Information System (INIS)

The masses of the proton-rich nuclides "8"5","8"6","8"7Mo and "8"7Tc have been measured with the Penning trap mass spectrometer SHIPTRAP at GSI. The measured mass excesses of these nuclei deviate from the values of the Atomic Mass Evaluation 2003 by up to 1.6 MeV, indicating a systematic shift of the mass surface in this region compared to previous measurements. A local mass extrapolation based on the new results has been made for the mass range A=80-95. Measured and extrapolated mass values and the derived separation energies have been compared to theoretical mass models. Taking into account the new mass excess values, rp-process network calculations have been performed. Preliminary results show changes in the final abundances for A=86-92 by up to a factor of 30. Results of measurements and calculations are presented, and the issue of a potential Zr-Nb cycle is ...

2010-03-15

23

Proton beam monitoring and forming on the target of isotope complex at INR linac  

International Nuclear Information System (INIS)

Special beam extraction channel is used at INR linac for isotope production. It starts from 160 MeV measuring and matching area of accelerator. This choice of beam extraction enables to direct to the target of isotope complex a proton beam of wide energy range up to 160 MeV. It is important for production of different types of nuclides. The measuring results of proton beam behavior in this region are presented. Required beam forming in 160 MeV measuring and matching area of accelerator and in beam extraction channel is discussed.

2010-01-01

24

Neutron leakage benchmarks for water moderators  

Energy Technology Data Exchange (ETDEWEB)

Fission reaction rates for four nuclides were measured in the leakage spectrum outside spherical water moderators of various radii surrounding a {sup 252}Cf neutron source. Using the MCNP transport code, matching calculations were made with highly detailed modeling of the measurement apparatus. The calculations predicted significantly higher leakage of neutrons in the epicadmium energy range than was found in the measurements. A discrepancy of the same sign but weaker magnitude was found for thermal neutrons. These discrepancies may be relevant to problems with criticality calculations in special cases.

1994-12-31

25

Project SAFE. Update of the SFR-1 safety assessment. Phase 1. Appendix A1: Inventory  

Energy Technology Data Exchange (ETDEWEB)

One of the aims in the safety assessment of SFR-1 is to estimate the release to the environment. In order to make these calculations there is a need to describe the inventory in greater detail. The new computerised database of waste in SFR-1 gives a good possibility to achieve this. The aim for project SAFE is to make both conservative and realistic radionuclide transport calculations. To achieve this goal there must be two inventories. The conservative inventory is the inventory used in the design of the repository, which in most parts is identical with the limits in the licence for SFR-1. There is a great interest to have good estimates of the volumes of the different waste types. A thorough prognosis should be made in 1999, but until then the latest one from 1995 could be used in the calculations. The total (actual) inventory of nuclides is calculated from the measurements of the easy-to-measure ...

1998-10-01

26

A Simulation Study on a Radioactive Nuclide's Distribution within a Fuel rod by a Tomographic Gamma Scanning  

Energy Technology Data Exchange (ETDEWEB)

Gamma scanning measurements are used to determine the radioactive nuclides from an irradiated fuel rod in a hot cell which is a routine task in the Irradiated Materials Examination Facility (IMEF) of the Korea Atomic Energy Research Institute (KAERI), Total gamma spectra of radioactive nuclides and the atomic ratio of {sup 134}Cs to {sup 137}Cs in a few segments of a single fuel rod are measured by the present gamma scanning system. For the purpose of determining the radioactive nuclide's distribution in detail within a fuel rod quantitatively, we attempt to upgrade the present gamma scanning system in this paper, therefore, an investigation of the feasibility of the tomographic gamma scanning (TGS) technique, which is one of the promising nondestructive assay (NDA) methods is proposed. The TGS technique is an efficient method and it has an accurate precision for the ...

2006-07-01

27

Examination of the natural radioactivity of building materials  

International Nuclear Information System (INIS)

Most important radionuclides naturally appearing in minerals used to form building materials are described. The frequently met ranges of concentrations of these radionuclides in the building materials composed from natural products as well as from power-plant wastes and metallurgic plant wastes are discussed and propositions concerning the limitation of presence of radioactive nuclides in the building materials are given, with special concern paid to materials for dwelling and public utility buildings. The elaborated technique of measuring potassium 40, radium 226 and thorium 228 concentrations is presented. Data on the organization of controlling-and-measuring laboratories in this field are given. (author).

1982-01-01

28

Understanding the peak asymmetry in alpha liquid scintillation with {beta}/{gamma} discrimination  

Energy Technology Data Exchange (ETDEWEB)

The peak evaluation in alpha liquid scintillation is known to be easy, mostly due to the gaussian shape of the peaks. However, we often observed a high-energy tail in addition to a pure gaussian function. This effect is only detectable with a high resolution {alpha} liquid scintillation spectrometer such as the PERALS trademark system. Indeed, its intrinsic resolution (180 keV for a 4 MeV {alpha} particle) is better than that obtained for conventional LSC spectrometers. The peak asymmetry was quantified using the Fisher's coefficient {gamma}{sub 1} (symmetry factor). We show that the main effect responsible for the asymmetry is internal conversion. Indeed, most of the even-even nuclides have low {alpha} intensity transitions leading to excited levels of their daughter nuclides. The internal conversion is almost equal to 100% and consequently produces a sum peak at higher energy. No generalization is possible for odd-even ...

2000-07-01

29

Investigation of Nuclide Importance to Functional Requirements Related to Transport and Long-Term Storage of LWR Spent Fuel  

Energy Technology Data Exchange (ETDEWEB)

The radionuclide characteristics of light-water-reactor (LWR) spent fuel play key roles in the design and licensing activities for radioactive waste transportation systems, interim storage facilities, and the final repository site. Several areas of analysis require detailed information concerning the time-dependent behavior of radioactive nuclides including (1) neutron/gamma-ray sources for shielding studies, (2) fissile/absorber concentrations for criticality safety determinations, (3) residual decay heat predictions for thermal considerations, and (4) curie and/or radiological toxicity levels for materials assumed to be released into the ground/environment after long periods of time. The crucial nature of the radionuclide predictions over both short and long periods of time has resulted in an increased emphasis on thorough validation for radionuclide generation/depletion codes. Current radionuclide generation/depletion codes have the capability to follow the ...

1995-01-01

30

Measurement of #gamma#-ray emission probabilities for "1"0"1Mo  

International Nuclear Information System (INIS)

"1"0"1Mo is one of the key nuclides in diagnosing fission burn-up. However, it's difficult to measure its nuclear decay data due to its short half-life. Present study concerns in the measurements of #gamma#-ray emission probabilities, P_#gamma#, of "1"0"1Mo and "1"0"1Tc using the balance of scheme method and the entire process recording. The P_#gamma# of "1"0"1Mo by the entire process recording is about 5% lower than that by using the balance of scheme method. The P_#gamma# of "1"0"1Tc using the two methods agree each other very well. So, it seems the #gamma#-ray emission probabilities as well as measurement method still need study further for "1"0"1Mo. (authors)

2006-07-01

31

Spectra of positrons and electrons emitted in "8"8Y decay  

International Nuclear Information System (INIS)

The "8"8Y decay has been studied with the aim to discover emission of monohromatic positrons (MP). The "8"8Sr(d,2N) reaction was used for production of "8"8Y (#beta#"+, Tsub(1/2)=106.6 days) nuclides. The prismatic beta spectrometer has been used to measure spectra of electrons and positrons. No MPs have been found. The resulting upper bound for their emission rate turned out to be lower than theoretically expected one.

32

Characterization of nuclear fuels by ICP mass-spectrometric techniques  

British Library Electronic Table of Contents (United Kingdom)

Isotopic analyses of radioactive materials such as irradiated nuclear fuel are of major importance for the optimization of the nuclear fuel cycle and for safeguard aspects. Among the mass-spectrometric techniques available, inductively coupled plasma mass spectrometry (ICP-MS) and thermal ionization mass spectrometry are the most frequently applied methods for nuclear applications. Because of the low detection limits, the ability to analyze the isotopic composition of the elements and the applicability of the techniques for measuring stable as well as radioactive nuclides with similar sensitivity, both mass-spectrometric techniques are an excellent amendment to classical radioactivity counting methods. The paper describes selected applications of multicollector ICP-MS in combination with c...

2008-01-01

33

Radwaste Drum Assay Technology by Segmented Gamma Scanning System  

Energy Technology Data Exchange (ETDEWEB)

Nuclear Act of Korea requires the manifest of low and intermediate level radioactive waste generated from nuclear power plants and other nuclear facilities prior to deliver to a disposal sites. Individual history records of the radioactive waste should be described the information about the activity of nuclides in the drum, total activity, weight, the type of waste. So a fully automated nuclide analysis assay system(non-destructive) of a radwaste drum was developed. For the nuclides that could not be analysed directly by MCA, the activities of the representative {gamma}-emitters(Cs-137, Co-60) contained in the drum were measured by using that system. Then the scaling factors were used to calculate the activities of {alpha} - and {beta}-emitters. This assay system divided a drum into 8 segments, a segment into 8 sectors to minimize analysis error, and used several methods(transmission ratio, differential ...

2009-01-15

34

Temperature measurement of 6He?+? ions confined in a transparent Paul trap  

British Library Electronic Table of Contents (United Kingdom)

The LPCTrap setup is a transparent Paul trap dedicated to the measurement of the ??? correlation coefficient a ?? in the ? decay of trapped radioactive nuclides. In a first experiment, the system has been used to record ?105 coincidences between the ? particles and recoiling ions emitted from the decay of 6He?+? ions. The analysis of the collected data has already shown that the size of the 6He?+? ion cloud confined in the Paul trap is a critical parameter, potentially limiting the accuracy on the a ?? measurement. We report here the precise determination of the trapped ion cloud temperature and size. This was performed by extracting the trapped ions toward a position sensitive micro channel plate detector at different phases of the RF driving field. We find a temperature T exp ?= 0.107(7)...

2011-01-01

35

Status of measurements of fission neutron spectra of Minor Actinides  

International Nuclear Information System (INIS)

The report considers experimental and theoretical works on studying the energy spectra of prompt neutrons emitted in spontaneous fission and neutron induced fission of Minor Actinides. It is noted that neutron spectra investigations were done for only a small number of such nuclei, most measurements, except those of Cf-252, having been carried out long ago by obsolete methods and imperfectapparatus. The works have no detailed description of experiments, analysis of errors, detailed numerical information about results of experiments. A conclusion is made that the available data do not come up to modern requirements. It is necessary to make new measurements of fission prompt neutron spectra of transuranium nuclides important for the objectives of working out a conception of minor actinides transmutation by means of special reactors. (author).

1997-03-01

37

Redetermination of several half-lives  

International Nuclear Information System (INIS)

The half-lives of "4"1Ar, "8"0"mBr, "9"4"mNb, "1"0"1Mo, "1"0"1Tc, "1"0"9Pd, "1"0"9"mPd, "1"2"2Sb, "1"2"2"mSb, "1"2"3"mSn, "1"5"2"mEu and "2"3"9Np have been measured more accurately compared to previous measurements. All of these half-lives and 39 others published earlier will be cited by M.S. Antony in the forthcoming project 'Chart of the nuclides - Strasbourg, 1990' due to appear early 1991. (author) 34 refs.; 4 figs.; 2 tabs.

38

Quality control and evaluation for environmental radiological baseline study of Guangdong Daya Bay nuclear power station  

International Nuclear Information System (INIS)

The main points of quality control methods and technique of environmental radiological baseline study of Guangdong Daya Bay Nuclear Power Station are reported. Results of intercalibration of international and inland laboratories are given. The random chosen samples are checked and compared with two measurement methods. The data obtained in Daya Bay environment are put to the correlation statistics test using the linear regression analysis method between the correlative items such as "4"0K activity by gamma spectrum measurement and potassium content by chemical analysis, total #alpha#(#beta#) activity and nuclide content, as well as environmental gamma radiation dose rate and TLD accumulation dose. The data of Daya Bay environmental radioactivity baseline level show good concordance and reliability.

39

Potential of AMS for Quantifying Long-Lived Reaction Products  

International Nuclear Information System (INIS)

Accelerator mass spectrometry (AMS) represents a powerful technique for the detection of long-lived radionuclides through ultra-low isotope ratio measurements. In many cases, counting atoms rather than decays yields much higher sensitivities. The potential of AMS will be demonstrated on typical radionuclides of interest with half-lives between some tens of years up to a hundred million years. The precise measurement of the 27Al(n,2n)26Al excitation function will be exemplified. Lack of information exists for a list of nuclides as pointed out by nuclear data requests. A brief overview on detection limits and some applications for selected long-lived radionuclides is given.

2005-05-24

40

Neutron inelastic scattering to octupole states in single-closed-shell nuclei  

International Nuclear Information System (INIS)

Differential cross sections for the excitation of the first octupole-vibrational state in the closed-neutron-shell nuclides "8"8Sr and "9"0Zr and in the closed-proton shell-nuclei sup(116,118,120,124)Sn by 11 MeV neutrons are presented. The distorted-wave Born approximation is used to obtain deformation lengths, delta(3"-) for each state. Results are compared with earlier measurements of inelastic proton scattering to the same states. Although limited resolution in the neutron time-of-flight spectrometer complicates the interpretation of the Sn data, the overall conclusion that deltasub(nn')(3"-) approx. deltasub(pp')(3"-) is supported by all of the measurements. (orig.).

41

Measurement of cumulative and independent yields of fission products from thermal-neutron fission of /sup 242//sup m/ Am  

Energy Technology Data Exchange (ETDEWEB)

The mass and charge distributions in an unseparated mix of fission product nuclei from thermal-neutron fission of /sup 242m/Am were studied through semiconductor gamma-ray spectrometry. Samples of the fissionable material under study were irradiated in a vertical irradiation tube of the MIFI IRT research reactor. Following irradiation, measurements were made on aperture-calibrated semiconductor detectors. For broader identification of fission fragment nuclides three experiments were conducted that differed substantially in irradiation duration. The spectrum of gamma radiation from the mix of fission products and the time dependences of count rate at total absorption peaks were analyzed on SM-4 and Iskra-226 computers. The values of yields obtained were compared with data of investigations conducted earlier with other experimental methods, and also with the results of calculations.

1985-03-01

42

Development of a generic analysis code of dynamic compartment model for evaluation of doses in terrestrial biosphere  

International Nuclear Information System (INIS)

The release rate of a nuclide from a reactor or a radioactive waste disposal plant at the accident is not steady, but varies with time. The various parameters of a nuclide migration into environment vary also day after day, or with the seasons. In such cases, dynamic behavior of the nuclide in the environment must be taken into consideration. It is difficult for a mathematical model to involve all of mechanisms for the nuclide migration. The environment for evaluation of doses are usually divided into some of compartments in which a nuclide concentration is uniform. Time variations of the nuclide concentration in the compartment are described in simultaneous differential equations. The nuclide concentration can be solved as a time function, and the radiation doses, therefore, can be estimated as a time function. Generic analysis code for ...

1999-02-01

43

Measurement of gamma-ray detection efficiency in irradiated materials examination facility  

Energy Technology Data Exchange (ETDEWEB)

The detection efficiency of gamma scanning system in irradiated materials examination facility has been measured. Gamma-ray sources used in this experiment are Cs-Co standard sources a PWR spent fuel rod in which {sup 134}Cs and {sup 154}Eu peaks are clearly identified in the energy region of 500 to 1,600 keV. The distance between source and detector is about 1.6 m. A slit type collimator with 3 mm-width window and 30 mm-thick lead block are installed between source and detector. The detector is a HPGe detector. This equipment is mainly used in gamma scanning of irradiated nuclear fuel. The measured detection efficiency seems to be 1.89 x 10{sup -6} % for 1 MeV gamma-ray. With these results the activities of unknown sources could be measured. This results are expected to be used in the measurement of the absolute distribution of gamma emitting nuclides in nuclear fuel.

2001-05-01

44

Summarization of radioactive effluent monitoring in Daya Bay Nuclear Power Station 1994-2002  

International Nuclear Information System (INIS)

This paper introduces the radioactive effluent monitoring systems, measurement and quality control methods used in Daya Bay Nuclear Power Station from its commercial operation in 1994. The main work and experiences for the management of effluent release are discussed and analyzed. The radwaste data appear declining trend and are far blow the annual limit approved by the national Environmental Protection Bureau since 1995. The normalized release (unit GBq/GWa) of 9 years is as follows: liquid nuclides (except tritium) 11.1, liquid tritium 1.91 x 10"4, noble gas 2.03 x 10"4, halogen 0.13, aerosol 7.57 x 10"-"3. For "1"1"0"mAg, the average release from 1998 to 2002 has been reduced to 1/7 of the quantity in 1997

2004-05-01

45

Recent developments at ISOLTRAP towards a relative mass accuracy of exotic nuclei below $10^{-8}$  

CERN Document Server

During the last two years, the performance of the Penning trap mass spectrometer ISOLTRAP at ISOLDE/CERN (Geneva) has been considerably enhanced. Many technical improvements have been completed (i) to access nuclides that are produced in minute quantities of only 100 ions s/sup -1/, (ii) to increase the relative mass accuracy to measurements. (20 refs).

2003-01-01

46

High resolution gamma-ray spectrometry of culverts containing transuranic waste at the Savannah River Site  

Energy Technology Data Exchange (ETDEWEB)

A number of concrete culverts used to retrievably store drummed, dry, radioactive waste at the Savannah River Site (SRS), were suspected of containing ambiguous quantities of transuranic (TRU) nuclides. These culverts were assayed in place for Pu-239 content using thermal and fast neutron counting techniques. High resolution gamma-ray spectroscopy on 17 culverts, having neutron emission rates several times higher than expected, showed characteristic gamma-ray signatures of neutron emitters other than Pu-239 (e.g., Pu-238, Pu/Be, or Am/Be neutron sources). This study confirmed the Pu-239 content of the culverts with anomalous neutron rates and established limits on the Pu-239 mass in each of the 17 suspect culverts by in-field, non-intrusive gamma-ray measurements.

1990-01-01

47

High resolution gamma-ray spectrometry of culverts containing transuranic waste at the Savannah River Site  

Energy Technology Data Exchange (ETDEWEB)

A number of concrete culverts used to retrievably store drummed, dry, radioactive waste at the Savannah River Site (SRS), were suspected of containing ambiguous quantities of transuranic (TRU) nuclides. These culverts were assayed in place for Pu-239 content using thermal and fast neutron counting techniques. High resolution gamma-ray spectroscopy on 17 culverts, having neutron emission rates several times higher than expected, showed characteristic gamma-ray signatures of neutron emitters other than Pu-239 (e.g., Pu-238, Pu/Be, or Am/Be neutron sources). This study confirmed the Pu-239 content of the culverts with anomalous neutron rates and established limits on the Pu-239 mass in each of the 17 suspect culverts by in-field, non-intrusive gamma-ray measurements.

1990-12-31

48

Evaluation of induced radioactivity in 10 MeV-electron irradiated spices, (1)  

International Nuclear Information System (INIS)

Black pepper, white pepper, red pepper, ginger and turmeric were irradiated with 10 MeV electrons from a linear accelerator to a dose of 100 kGy and radioactivity was measured in order to estimate induced radioactivity in the irradiated foods. Induced radioactivity could not be detected significantly by #gamma#-ray spectrometry in the irradiated samples except for spiked samples which contain some photonuclear target nuclides in the list of photonuclear reactions which could produce radioactivity below 10 MeV. From the amount of observed radioactivities of short-lived photonuclear products in the spiked samples and calculation of H_5_0 according to ICRP Publication 30, it was concluded that the induced radioactivity and its biological effects in the 10 MeV electron-irradiated natural samples were negligible in comparison with natural radioactivity from "4"0K contained in the samples. (author).

49

Determination of plutonium metal origins  

Energy Technology Data Exchange (ETDEWEB)

Forensic signatures are present in any Pu sample that can determine the sample`s origin: isotopic ratio of Pu, progeny species that grow into the sample, and contaminant species left over from incomplete purification of the Pu in fuel reprocessing. In the context of intelligence information, this can result in attribution of responsibility for the product of clandestine proliferant operations or material smuggled from existing stockpiles. A list of signature elements and what can be determined from them have been developed. Work needs to be done in converting concentrations of signature species into a quantitative forensic analysis, particularly in regard to reactor performance, but this should require only a small effort. A radiochemical analysis scheme has been developed for measuring these nuclides; more work is needed, particularly for determining fission product concentrations. A sample of Pu metal has been analyzed and several parameters ...

1995-02-01

50

Application of alpha and gamma spectroscopy to the quantitative analysis of transuranium nuclides in nuclear fuel  

Energy Technology Data Exchange (ETDEWEB)

In nuclear fuel with a burn-up of 33 kg/t U and 52 kg/t U 15 transuranium nuclides /sup 237/Np to /sup 246/Cm have been determined by alpha and gamma spectroscopy after radiochemical separation.

1984-11-01

51

Theoretical and scaling factors methods to calculate the radioactivity in operational waste streams from Unit 1 at Cernavoda NPP  

International Nuclear Information System (INIS)

The main goal of this paper is to present a methodology for calculating the radioactivity in the moderator and heat transport systems of Cernavoda NPP Unit 1, with the intention to improve the knowledge on the radionuclides inventories in the operational waste streams, and to aid the licensing process of new near surface repository. In the present paper we describe our methodology for estimating H-3 and C-14 production rates in the heavy-water moderator and heat transport systems using the capacity factors from 1997 to 2007 years. The radioactivity of the difficult-to-measure nuclides is predicted by scaling method using measured concentration in reference CANDU 6 reactor Gentilly-2. The difficult-to-measure radionuclides of primary interest in this study were those with long half-lives which have a significant role for post-closure safety assessment. The equation used to scale fission products (parents ...

2009-05-27

52

Review of integral data on higher transactinides  

International Nuclear Information System (INIS)

A review of the status of integral measurements is presented for "2"4"0Pu, "2"4"1Pu, "2"4"2Pu, "2"4"1Am and "2"4"3Am. This review includes integral measurements pertinent to thermal reactor systems, i.e., thermal cross sections and resonance integrals, as well as measurements for fast reactor systems. It appears that for these nuclides the data for thermal reactors are in good shape; however, more work is recommended in defining the branching ratio of the capture cross section of "2"4"1Am to the isomeric and ground states of "2"4"2Am. Also, benchmark irradiation data are needed for cross section data testing using depletion/production codes. For fast reactors, experiments are in progress, in the UK, in France, and also in the US, with partial results available at this time. Fast integral data obtained from these measurements will be very beneficial. The recommendation pertaining to ...

1979-05-01

53

Spent fuel sabotage aerosol ratio program : FY 2004 test and data summary  

International Nuclear Information System (INIS)

This multinational, multi-phase spent fuel sabotage test program is quantifying the aerosol particles produced when the products of a high energy density device (HEDD) interact with and explosively particulate test rodlets that contain pellets of either surrogate materials or actual spent fuel. This program has been underway for several years. This program provides data that are relevant to some sabotage scenarios in relation to spent fuel transport and storage casks, and associated risk assessments. The program also provides significant technical and political benefits in international cooperation. We are quantifying the Spent Fuel Ratio (SFR), the ratio of the aerosol particles released from HEDD-impacted actual spent fuel to the aerosol particles produced from surrogate materials, measured under closely matched test conditions, in a contained test chamber. In addition, we are measuring the amounts, nuclide content, size ...

54

Yields of short-lived fission products produced following "2"3"5U(n_t_h,f)  

International Nuclear Information System (INIS)

Measurements of gamma-ray spectra, following the thermal neutron fission of "2"3"5U have been made using a high purity germanium detector at the University of Massachusetts Lowell (UML) Van de Graaff facility. The gamma spectra were measured at delay times ranging from 0.2 s to nearly 10000 s following the rapid transfer of the fission fragments with a helium-jet system. On the basis of the known gamma transitions, forty isotopes have been identified and studied. By measuring the relative intensities of these transitions, the relative yields of the various precursor nuclides have been calculated. The results are compared with the recommended values listed in the ENDF/B-VI fission product data base (for the lifetimes and the relative yields) and those published in the Nuclear Data Sheets (for the beta branching ratios). This information is particularly useful for the cases of short-lived fission products ...

1998-08-01

55

Excitation functions for proton-induced reactions on natural hafnium: Production of {sup 177}Lu for medical use  

Energy Technology Data Exchange (ETDEWEB)

There is an increasing interest in using radioisotopes of rare earth elements for internal radiotherapy and for imaging in nuclear medicine. {sup 177}Lu is one of the promising radionuclides. This article reports on the first measurements of the excitation function for the production of {sup 177}Lu with proton-beam energies up to 17 MeV on natural hafnium targets. The experimental cross sections for the reaction {sup nat}Hf(p,x){sup 177}Lu were obtained by the activation of a stacked-foil target and subsequent gamma spectrometry. Theoretical cross sections were calculated up to 35 MeV with the EMPIRE nuclear reaction model code. The measured and calculated cross sections were used for deriving the thick-target yields and for estimating the production of other nuclides than {sup 177}Lu. Measured production cross sections of {sup 175,176,177,178}Ta on the same target are also presented.

2009-11-15

56

Excitation functions for proton-induced reactions on natural hafnium: Production of "1"7"7Lu for medical use  

International Nuclear Information System (INIS)

There is an increasing interest in using radioisotopes of rare earth elements for internal radiotherapy and for imaging in nuclear medicine. "1"7"7Lu is one of the promising radionuclides. This article reports on the first measurements of the excitation function for the production of "1"7"7Lu with proton-beam energies up to 17 MeV on natural hafnium targets. The experimental cross sections for the reaction "n"a"tHf(p,x)"1"7"7Lu were obtained by the activation of a stacked-foil target and subsequent gamma spectrometry. Theoretical cross sections were calculated up to 35 MeV with the EMPIRE nuclear reaction model code. The measured and calculated cross sections were used for deriving the thick-target yields and for estimating the production of other nuclides than "1"7"7Lu. Measured production cross sections of "1"7"5","1"7"6","1"7"7","1"7"8Ta on the same target are also presented.

2009-11-01

57

Investigations of excretion rates of the radionuclides {sup 230}Th, {sup 226}Ra, {sup 210}Pb and {sup 210}Po of persons of the general population and of workers in selected regions in Germany  

Energy Technology Data Exchange (ETDEWEB)

According to ICRP 60 and European-Directive 96/29, Naturally Occurring Radioactive Materials (NORM) and Technical Enriched Naturally Occurring Radioactive Materials (TENORM) have to take the radiation protection of the general population as well as of workers into account. The German radiation protection regulations stress that particularly. In connection with these regulations, various measurement programs have been and still are performed to investigate the relevant exposure paths. One of these programs is the determination of the intake of natural occurring radionuclides of the uranium decay series in individuals of the public, in exposed regions and houses and also at NORM workplaces by excretion analysis. Excretion analysis surveillance is one of the common tools for internal dosimetry. Sources of primordial radionuclides could be the ingestion of foodstuff and water and the incorporation of (mostly airborne) pollution on work places. The main focus in this ...

2006-07-01

58

Prompt fission neutron energy spectra induced by fast neutrons  

International Nuclear Information System (INIS)

Prompt fission neutron energy spectra for "2"3"5U and "2"3"9Pu have been measured for fission neutron energies greater than the energy of the incident neutrons inducing fission. The measurements were undertaken to investigate the shape dependence of the fission neutron spectra upon both the incident neutron energy and the mass of the nucleus undergoing fission. Measurements were made for both nuclides at incident neutron energies of 0.50, 1.50, 2.50 and 3.50 MeV. The data are presented either as relative yields or as ratios of measured spectra to that of "2"3"5U at 0.50 MeV. Incident neutrons were produced by the "7Li(p,n)"7Be reaction using a pulsed, bunched proton beam from the 5.5 MV Van de Graaff accelerator at the University of Massachusetts Lowell Radiation Laboratory. Fission neutrons were detected by a thin liquid scintillator with good time resolution capabilities. Neutron ...

59

Three-step photoionization of mercury for application to separation of mercury isomers  

International Nuclear Information System (INIS)

Development of techniques for separating isomeric nuclides is important to the investigation of schemes for gamma-ray lasers. In preparation for an experiment to separate 10_1_4 atoms of the /sub 197m/Hg (299 keV, tau/sub 1/2/ = 24 hours) isomer, we report isotopically selective resonance ionization of mercury atoms. This has been accomplished by three-step excitation via the 6_3P"1 and 8_1S"0 excited states, using three collinear pulsed laser beams of 254, 286, and 532 nm wavelengths from a Nd:YAG and two dye lasers. These beams were passed through a closed mercury-vapor cell containing electrostatic plates to which the ions were drawn. Ion current and fluorescent radiation were measured as a function of laser frequency. Hyperfine structures for the 254- and 286-nm transitions were observed.

60

The measurement of the fission product ratios, {sup 134}Cs/{sup 137}Cs and {sup 154}Eu/{sup 137}Cs in spent PWR fuel by gamma scanning method  

Energy Technology Data Exchange (ETDEWEB)

We obtained the ratios of {sup 134}Cs/{sup 137}Cs and {sup 154}Eu/{sup 137}Cs in spent PWR fuels with gamma scanning equipment of irradiated material examination facility. The fuel segments, of which the burn-up is about 40 GWD/MTU and its cooling time is 8.4 years, are prepared in Post Irradiated Examination Facility and transported to IMEF. By considering of multi-peaks of {sup 134}Cs and {sup 154}Eu, we obtained the relative efficiency of the gamma scanning system as a function of energy. And finally we obtained the number ratios of radioactive nuclides in 72 fuel pellets, radioactive {sup 134}Cs/{sup 137}Cs and {sup 154}Eu/{sup 137}Cs. (author). 4 refs., 27 tabs., 28 figs.

1997-10-01

61

The measurement of the fission product ratios, "1"3"4Cs/"1"3"7Cs and "1"5"4Eu/"1"3"7Cs in spent PWR fuel by gamma scanning method  

International Nuclear Information System (INIS)

We obtained the ratios of "1"3"4Cs/"1"3"7Cs and "1"5"4Eu/"1"3"7Cs in spent PWR fuels with gamma scanning equipment of irradiated material examination facility. The fuel segments, of which the burn-up is about 40 GWD/MTU and its cooling time is 8.4 years, are prepared in Post Irradiated Examination Facility and transported to IMEF. By considering of multi-peaks of "1"3"4Cs and "1"5"4Eu, we obtained the relative efficiency of the gamma scanning system as a function of energy. And finally we obtained the number ratios of radioactive nuclides in 72 fuel pellets, radioactive "1"3"4Cs/"1"3"7Cs and "1"5"4Eu/"1"3"7Cs. (author). 4 refs., 27 tabs., 28 figs.

1988-09-18

62

Plutonium in biota from an east Tennessee floodplain forest  

International Nuclear Information System (INIS)

"2"3"9 "2"4"0Pu concentrations were measured in biota from a 30-year-old contaminated floodplain forest in Tennessee. Concentration ratios relative to soil, for plutonium in litter, invertebrate cryptozoans, herbaceous ground vegetation, orthoptera and small mammals were approximately 10"-"1, 10"-"2, 10"-"3, and 10"-"4, respectively. Concentration ratios (CR) for plutonium in biota from the floodplain forest are less than CR values from other contaminated ecosystems in the USA. Presumably, this is due to humid conditions and greater rainfall which minimize resuspension as a physical transport mechanism to biota. Plutonium and radiocesium concentrations are correlated in biota from the forest at Oak Ridge and also from Mortandad Canyon in New Mexico. The cause of the covariance between concentrations of these elements is unknown. Nevertheless, the existence of these relationships suggests that it is possible to predict plutonium in biota from radiocesium ...

63

Mass and charge distributions in the very asymmetric thermal neutron induced fission of the odd-Z nucleus {sup 242m}Am  

Energy Technology Data Exchange (ETDEWEB)

Yields of light fission products (A = 68, 70-84, 87, 88, 94, 96, 98, 102 and 106-108), their kinetic energies and nuclear charge distributions (A 71-84, 87 and 88) in the thermal neutron induced fission of the odd-Z nucleus {sup 242m}Am(Z = 95) were measured using the mass-separator Lohengrin at the Institute Laue-Langevin in Grenoble (France). The mass yield curve shows a fine structure at A = 70, probably due to shell and/or odd-even effects affecting also the nuclear charge distribution. The analysis of isotopic chain yields gives evidence for a very low excitation energy of the lightest fission fragments observed. A preferential formation of fragments with even Z is found for this odd-Z compound nucleus. Calculated values for the local odd-even effect are comparable with those for the neighbouring even-Z fissile nuclides and increase from 13% to 30% with increasing asymmetry of the mass split (A{sub L} = 84 to 68 and Z{sub L} = 35 to 28). ...

1999-10-25

64

Isolation and determination of "9"0Sr, "2"2"6Ra, "2"2"8Ra and "2"1"0Pb in food  

International Nuclear Information System (INIS)

A procedure is described for the isolation and determination of "9"0Sr, "2"2"6Ra, "2"2"8Ra and "2"1"0Pb in food. These nuclides are highly radiotoxic, above all for babies and children. Samples are dry ashed, alkali metals are removed as carbonates. Separation from other matrix ions and separation of Ra, Sr and Pb can be achieved with a column of Sr-Spec, an immobilized crown ether. For activity measurements membrane filters with SrSO_4, Ba(Ra)SO_4 and PbS are prepared. Ra is determined by gamma-spectrometry, "9"0Sr and "2"1"0Pb are determined by low-level-betacounting. The determination limits are 10 mBq/kg for "9"0Sr and "2"1"0Pb and 50 mBq/kg for "2"2"6Ra and "2"2"8Ra. The procedure is useful for all kinds of foodstuff. (orig.).

65

Alpha-spectrometric determination of uranium, plutonium, americium and curium isotope content in 'hot' particles and irradiated nuclear fuel  

International Nuclear Information System (INIS)

A method for express determination of "2"3"4"-"2"3"8U, "2"3"8"-"2"4"2Pu, "2"4"1"-"2"4"3Am and "2"4"2"-"2"4"4Cm content in fuel 'hot' particles and spent nuclear fuel is offered. The method is based on precision measurement of a sample #alpha# activity followed by estimate of relative contributions of individual nuclides, or groups of radionuclides, to total activity. Segregation in separate fractions of uranium, plutonium, americium and curium was made with the help of ion-exchange chromatography. Results are presented of "2"3"4"U, "2"3"8U, "2"3"8"Pu,"2"3"9"+"2"4"0Pu, "2"4"1Pu, "2"4"2Pu, "2"4"1"Am, "2"4"2"mAm, "2"4"3Am "2"4"2"Cm and "2"4"4Cm definition in 'hot' particles sampled in Chernobyl NPP surroundings, Opportunities to apply this method for identifying radionuclide content of spent nuclear fuel are discussed.

66

Yields of Residual Nuclei from Proton-Irradiated Materials  

International Science & Technology Center (ISTC)

Experimental and Theoretical Study of the Residual Nuclide Production in 40-2600 MeV Proton-Irradiated Thin Targets of ADS Basic Materials

67

Prediction of the delayed neutron yields for actinide nuclides  

Energy Technology Data Exchange (ETDEWEB)

A prediction of delayed neutron yields for actinides which are important in the nuclear energy field is given. The prediction is based on a correlation related to a suggested cluster structure of the nucleus. (author).

1989-01-01

68

American National Standard ANSI/ANS-8.15-1983: Nuclear criticality control of special actinide elements  

Energy Technology Data Exchange (ETDEWEB)

The American National Standard, `Nuclear Criticality Safety in Operations with Fissionable Materials Outside Reactors` ANSI/ANS-8.1- 1983 provides guidance for the nuclides [sup 233]U, [sup 235]U, and [sup 239]Pu These three nuclides are of primary interest in out-of-reactor criticality safety since they are the most commonly encountered in the vast majority of operations. However, some operations can involve nuclides other than `U, `U, and `Pu in sufficient quantities that their effect on criticality safety could be of concern. The American National Standard, `Nuclear Criticality Control of Special Actinide Elements` ANSI/ANS-8.`15-1983 (Ref 2), provides guidance for fifteen such nuclides.

1996-12-31

69

Actinide transmutation in nuclear reactors  

Energy Technology Data Exchange (ETDEWEB)

Of some interest is the comparison between the actinide nuclide burning up (fission) rates such as americium 241, americium 242, curium 244, and neptunium 237, in the reactors with fast or thermal neutron spectra.

1993-12-31

70

Actinide transmutation in nuclear reactors  

International Nuclear Information System (INIS)

Of some interest is the comparison between the actinide nuclide burning up (fission) rates such as americium 241, americium 242, curium 244, and neptunium 237, in the reactors with fast or thermal neutron spectra.

1992-09-14

71

Challenges in environmental radiological surveillance around nuclear facilities  

International Nuclear Information System (INIS)

To accomplish the environmental radiological surveillance need of India's ambitious nuclear power programme, Health Physics Division is infusing new technologies and improved analytical techniques for day to day measurements of various radionuclides in different environmental matrices. It is essential to have techniques for measuring the concentration of radionuclides just above the background level since the discharges from the nuclear facilities are very low i.e. in the range of 5-10% of the prescribed discharge limits by the regulatory bodies. In view of developing ultra-sensitive techniques, the aim of ongoing programmes of the division is to meet the challenges of measuring ultra trace level of radioactivity by adopting state of art new instrumentation and improved sample processing techniques. This will allow us to measure the lowest level of radioactivity (3H, 90Sr, 137Cs, 239+240Pu, etc.) in the ...

2007-06-05

72

Reevaluation of the average prompt neutron emission multiplicity (nubar) values from fission of uranium and transuranium nuclides  

Science.gov (United States)

In response to a need of the safeguards community, we have begun an evaluation effort to upgrade the recommended values of the prompt neutron emission multiplicity distribution, P/sub nu/ and its average value, nubar. This paper will report on progress achieved thus far. The evaluation of the uranium, plutonium, americium and curium nuclide's nubar values will be presented. The recommended values will be given and discussed. 61 references.

1984-01-01

73

Neutron multiplicities for the transplutonium nuclides  

Science.gov (United States)

This paper continues, with respect to the transplutonium nuclides, earlier efforts to collate and evaluate data from the scientific literature on the prompt neutron multiplicity distribution from fission and its first moment = ..sigma..nuPnu. The isotopes considered here for which P/sub nu/ and or data (or both) were found in the literature are of americium (Am), curium (Cm), berkelium (Bk), californium (Cf), einsteinium (Es), fermium (Fm), and nobelium (No).

1985-01-01

74

Neutron multiplicities for the transplutonium nuclides  

Energy Technology Data Exchange (ETDEWEB)

This paper continues, with respect to the transplutonium nuclides, earlier efforts to collate and evaluate data from the scientific literature on the prompt neutron multiplicity distribution from fission and its first moment = ..sigma..nuPnu. The isotopes considered here for which P/sub nu/ and or data (or both) were found in the literature are of americium (Am), curium (Cm), berkelium (Bk), californium (Cf), einsteinium (Es), fermium (Fm), and nobelium (No).

1985-01-01

75

Application of alpha and gamma spectroscopy to the quantitative analysis of transuranium nuclides in nuclear fuel  

International Nuclear Information System (INIS)

In nuclear fuel with a burn-up of 33 kg/t U and 52 kg/t U 15 transuranium nuclides "2"3"7Np to "2"4"6Cm have been determined by alpha and gamma spectroscopy after radiochemical separation. (author).

76

Analysis of Am-242m in solidified products  

International Nuclear Information System (INIS)

When solidified products made from low-level radioactive waste with melting treatment are disposed of in near surface repositories, concentrations of the radionuclides contained in the waste package have to be evaluated. Americium-242m is one of the targeted nuclides. In this study, simple analytical methods to evaluate the activity of "2"4"2"mAm are studied. Americium, Cm and Eu in a sample solution made from simulated solidified product and tracer of "1"5"2Eu and "2"4"4Cm and unknown solution of "2"4"1"+"2"4"2"m"+"2"4"3Am were separated from matrix elements with TRU resin. The fraction containing Eu, Am and Cm was passed through pyridine resin to separate Am from Eu and Cm. The contamination factor of "2"4"4Cm/"2"4"1Am was less than 3.0x10"-"3. Curium-242 generated from "2"4"2Am was measured to evaluate the activity of "2"4"2"mAm. The fraction containing Eu, Am and Cm was also passed through TEVA resin to separate Am and Cm from Eu. Beta-ray ...

2006-10-01

77

Radon generation and transport in and around a gold mine tailings dam in South Africa  

Energy Technology Data Exchange (ETDEWEB)

Naturally Occurring Radioactive Material (N.O.R.M.) occurs in most soil and rock, and by mining and mineral processing, some of the radionuclides are significantly enhanced. An in-situ gamma-ray detector called M.E.D.U.S.A., has been used to produce a map of relative activity concentrations in a gold mine tailings dam on the Witwatersrand in South Africa. A CsI(Na) scintillation detector is used in this system. M.E.D.U.S.A. spectra obtained from the survey were analyzed using the Full-Spectrum Analysis (F.S.A.) procedure to compute the {sup 40}K, {sup 238}U and {sup 232}Th activity concentrations. The activity concentrations are used with global positioning data (G.P.S.) to produce the concentration maps. A hyper-pure germanium gamma-ray detector (Hp Ge) was used to measure gamma-rays from the naturally occurring nuclides for soil samples taken at different points on the site to calibrate the M.E.D.U.S.A. system. Radon soil gas ...

2006-07-01

78

Experimental investigation of dose calibrator response for "1"2"5I brachytherapy solutions contained in 5 mL plastic syringes and 2 mL conical glass v-vials as a function of filling mass  

International Nuclear Information System (INIS)

The effect of measurement geometry on the determination of the activity of solutions containing "1"2"5I for use in brachytherapy applications has been investigated for 5 mL plastic syringes and 2 mL conical glass dose vials as a function of filling mass. New dial settings for the syringes over a filling mass range of 1 to 3 g have been determined to be 497#+-#8 and 469#+-#8 (expanded, k=2, uncertainties) for the NIST Capintec CRC-12 and Capintec CRC-35R, respectively, with any effect due to the filling mass lying within the uncertainty in the activity calibration. A filling mass effect was observed in the dose vials, causing a 10.5% reduction in the chamber response from a 2 g filling mass to 1 g. Dial settings at 2 g were experimentally found to be 143#+-#2 and 135#+-#2 (expanded uncertainties) for the NIST Capintec CRC-12 and Capintec CRC-35R, respectively. The appropriate dial settings for the same vials with a 1 g filling mass were found to be 120#+-#2 and ...

2002-07-01

79

Experience and recent developments in nuclear forensics at the Institute of Isotopes  

International Nuclear Information System (INIS)

Full text: Based on experience with nuclear material confiscated in Hungary from illicit trafficking activities in the nineties it has been decided that traditional gamma-spectrometry should be complemented by destructive analytical techniques. The 17/1996 (I. 31.) Korm. Governmental Decree delegated the identification, categorization and characterization tasks to the Institute of Isotopes, Budapest. Routine gamma-spectrometric methods have been further developed aiming at the i) age (production date) determination of seized samples and complete (nondismountable) uranium-bearing items (such as fresh fuel bundles and fission chambers) by HRGS technique, ii) improvement of measurement accuracy and reliability. Starting in 2005 mass spectrometry (ICP-SFMS) and scanning electron microscopy have been implemented to characterize nuclear samples in more detail and to analyze environmental samples both for isotopic and elemental composition focusing on long-lived ...

80

11. Preparation of natural radioactive materials  

International Nuclear Information System (INIS)

Uranium and thorium ores are the source of natural radionuclides. Briefly described are the original and current methods of long-lived nuclide separation ("2"3"8U, "2"3"5U, "2"2"6Ra, "2"3"0Th, "2"3"1Pa, "2"2"7Ac, "2"3"2Th, "2"2"8Ra+"2"2"8Ac, "2"2"8Th), some short-lived nuclides ("2"3"4Th and "2"2"8Ac), radon, short-lived radon daughter products and long-lived radon daughter products ("2"1"0Pb, "2"1"0Bi, "2"1"0Po). Some nuclides, such as "2"1"0Po or "2"3"1Pa can more easily be producedin reactors. (Ha).

81

Calibration of the Capintec CRC-712M dose calibrator for "1"8F  

International Nuclear Information System (INIS)

Primary standardisation was performed on a solution of "1"8F using the 4#pi##beta#-#gamma# coincidence counting efficiency-tracing extrapolation method with "6"0Co used as a tracer nuclide. The result was used to calibrate the ANSTO secondary standard ionisation chamber which is used to disseminate Australian activity standards for gamma emitters. Using the secondary activity standard for "1"8F, the Capintec CRC-712M dose calibrator at the Australian National Medical Cyclotron (NMC) Positron Emission Tomography (PET) Quality Control (QC) Section was calibrated. The dial setting number recommended by the manufacturer for the measurement of the activity of "1"8F is 439. In this work, the dial setting numbers for the activity measurement of the solution of "1"8F in Wheaton vials were experimentally determined to be 443+/-12, 446+/-12, 459+/-11, 473+/-15 for 0.1, 1, 4.5 and 9ml solution volumes, respectively. The uncertainties ...

2006-04-01

82

Radioactivity of people in Finland after the Chernobyl accident in 1986  

International Nuclear Information System (INIS)

After the reactor accident at Chernobyl on April 26, 1986 radioactive fallout was carried by air currents to most parts of Europe. The radioactive air currents reached Finland on April 27. Immediately after the arrival of such air in Finland, contamination of people by radioactive nuclides began via inhalation of this air. The ingestion route become important later, when radionuclides were transported via different foodchains to man. To determine the level of radionuclides in the body and to estimate the internal radiation doses caused by the Chernobyl accident, whole-body counting measurements were performed. The results of whole-body counting of six different groups of Finnish people measured during 1986 after the accident at Chernobyl are reported. Three were reference groups measured routinely once or twice annually, two groups were comprised of workers at nuclear power stations and one group ...

2004-02-01

83

Systematics of average radiative width of heavy nuclides  

Energy Technology Data Exchange (ETDEWEB)

Systematics of neutron capture radiative width were studied in the target element range from Th to Cm. Reduced radiative widths were analyzed with a simple radiative width formula based on E1 transition. Average radiative width is presented with the standard deviation of 15%. (author)

1999-03-01

84

Nuclear data sheets update for A = 203  

Energy Technology Data Exchange (ETDEWEB)

Experimental results of nuclear reaction and radiative decay for A = 203 nuclides are evaluated. Adopted properties for all the nine isobars, Au, Hg, Tl, Pb, Bi, Po, At, Rn, Fr of mass 203 are presented. Nothing is yet known for [sup 203]Os. 96 refs.

1993-09-01

85

Nuclear data sheets update for A = 203  

International Nuclear Information System (INIS)

Experimental results of nuclear reaction and radiative decay for A = 203 nuclides are evaluated. Adopted properties for all the nine isobars, Au, Hg, Tl, Pb, Bi, Po, At, Rn, Fr of mass 203 are presented. Nothing is yet known for "2"0"3Os. 96 refs.

86

Dependence of fast reactor fuel burnup characteristics on nuclear data libraries  

International Nuclear Information System (INIS)

In the framework of the development of burnup calculation method for commercial fast reactors, a sensitivity analysis was carried out to clarify the dependence of fuel burnup characteristics on nuclear data libraries (NDLs). The following NDLs were compared: JEF-2.2, ENDF/B-VI Release 5, JENDL-3.2 and JENDL-3.3. The NDL-dependence of material balance for main heavy metal nuclides ("2"3"5U, "2"3"8U, "2"3"9Pu, "2"4"0Pu and "2"4"1Pu) was small, since the number densities at the end of one-cycle burnup did not change over 1 or 2% among the above-mentioned libraries. Relatively large differences were found for minor actinide nuclides, especially for "2"3"6U, "2"3"7Np, "2"4"2"mAm, "2"4"3Am and curium isotopes. The number densities for these nuclides after burning up showed remarkable NDL-dependence over 5% through 50%. A burnup sensitivity analysis system based on the generalized perturbation theory enabled us to find out ...

2005-04-01

87

Application of rhenium-188 HEDP in bone metastases therapy  

International Nuclear Information System (INIS)

Radionuclide bone metastases therapy is a major achievement of nuclear medicine. Development of less radiotoxic and more effective radiopharmaceuticals is therefore a challenge for radiopharmacists and industry. This paper reviews the application of rhenium-188 HEDP as a reactor- or generator-produced nuclide for bone metastases therapy. (author)

88

Total and spontaneous fission half-lives of the americium and curium nuclides  

Science.gov (United States)

The total half-life and the half-life for spontaneous fission are evaluated for the various long-lived nuclides of interest. Recommended values are presented for /sup 241/Am, /sup 242m/Am, /sup 243/Am, /sup 242/Cm, /sup 243/Cm, /sup 244/Cm, /sup 245/Cm, /sup 246/Cm, /sup 247/Cm, /sup 248/Cm, and /sup 250/Cm. The uncertainties are provided at the 95% confidence limit for each of the recommended values.

1984-01-01

89

Total and spontaneous fission half-lives of the americium and curium nuclides  

International Nuclear Information System (INIS)

The total half-life and the half-life for spontaneous fission are evaluated for the various long-lived nuclides of interest. Recommended values are presented for "2"4"1Am, "2"4"2Am, "2"4"3Am, "2"4"2Cm, "2"4"3Cm, "2"4"4Cm, "2"4"5Cm, "2"4"6Cm, "2"4"7Cm, "2"4"8Cm, and "2"5"0Cm. The uncertainties are provided at the 95% confidence limit for each of the recommended values. (author).

1985-06-01

90

Activation method for determination of Pb, La, Zr and Ti macrocomponents in lead-lanthanum zirconate-titanate materials on a neutron generator  

International Nuclear Information System (INIS)

Instrumental neutron activation analysis is used for simultaneously determination of macrocomponents in ferroelectric materials LLZT. Pb, Zr, Ti have been determined by "2"0"3Pb, "8"9Zr and "4"8Sc nuclides created by fast neutron (14.5 MeV) activation. Application of paraffine as neutron moderator and reflector allows to simultaneously determine lanthanum by "1"4"0La nuclide. It has been shown that zirconium, titanium and lanthanum can be determined with the accuracy of #+-#0.1 mas. % and lead - #+-#0.7 mas. %.

91

Measurement of. beta. decay energies of short-lived neutron-rich atomic nuclei in the mass range 101 less than or equal toA less than or equal to106 and A=109. Messung von Beta-Zellverfallsenergien kurzlebiger, neutronenreicher Atomkerne im Massenbereich 101 less than or equal toA less than or equal to106 und A=109  

Energy Technology Data Exchange (ETDEWEB)

Q/sub ..beta..-values are determined for 18 nuclei (Zr-, Nb-, Mo-, Tc-, Ru- and Rh-nuclides) with mass numbers 101 less than or equal toA less than or equal to106 and A=109 from measurements of beta decay energies which were carried out at the LOHENGRIN mass separator at the Institut Laue-Langevin in Grenoble (France). The given Q/sub ..beta..-values between 2 and 8 MeV show errors of about 1.5% (with the exception of /sup 103/Zr and /sup 105/Nb resp. and /sup 103/Tc for which larger errors result due to statistical resp. systematic reasons): /sup 101/Zr 5500+-70, /sup 101/Nb 4580+-45, /sup 102/Zr 4670+-40, /sup 102/Nb 7230+-70, /sup 103/Zr 6790+-240, /sup 103/ 5740+-70, /sup 103/Mo 3575+-80, /sup 103/Tc 2585+-70, /sup 104/Nb 8250+-130, /sup 104/Mo 2180+-40, /sup 104/Tc 5520+-100, /sup 105/Nb 6570+-150, /sup 105/Mo 4885+-80, /sup 105/Tc 3750+-60, /sup 106/Mo 3515+-45, /sup 106/Tc 6540+-70, /sup 109/Ru 4150+-80, /sup 109/Rh 2550+-50 (all values ...

1986-10-31

92

Measurement of #beta# decay energies of short-lived neutron-rich atomic nuclei in the mass range 101 #<=# A #<=# 106 and A=109  

International Nuclear Information System (INIS)

Q_#beta#-values are determined for 18 nuclei (Zr-, Nb-, Mo-, Tc-, Ru- and Rh-nuclides) with mass numbers 101 #<=# A #<=# 106 and A=109 from measurements of beta decay energies which were carried out at the LOHENGRIN mass separator at the Institut Laue-Langevin in Grenoble (France). The given Q_#beta#-values between 2 and 8 MeV show errors of about 1.5% (with the exception of "1"0"3Zr and "1"0"5Nb resp. and "1"0"3Tc for which larger errors result due to statistical resp. systematic reasons): "1"0"1Zr 5500#+-#70, "1"0"1Nb 4580#+-#45, "1"0"2Zr 4670#+-#40, "1"0"2Nb 7230#+-#70, "1"0"3Zr 6790#+-#240, "1"0"3 5740#+-#70, "1"0"3Mo 3575#+-#80, "1"0"3Tc 2585#+-#70, "1"0"4Nb 8250#+-#130, "1"0"4Mo 2180#+-#40, "1"0"4Tc 5520#+-#100, "1"0"5Nb 6570#+-#150, "1"0"5Mo 4885#+-#80, "1"0"5Tc 3750#+-#60, "1"0"6Mo 3515#+-#45, "1"0"6Tc 6540#+-#70, "1"0"9Ru 4150#+-#80, "1"0"9Rh 2550#+-#50 (all values in keV). For the measurement of beta-gamma ...

93

Instrumentation for monitoring and control of water chemistry for light-water-cooled nuclear power plants  

Energy Technology Data Exchange (ETDEWEB)

Based on the IAPWS technical guidance on ''Instrumentation for Monitoring and Control of Cycle Chemistry for Steam-Water Circuits of Fossil-Fired and Combined Cycle Power Plants,'' the latest situation regarding instrumentation for nuclear power plants is discussed. As a result of the discussion, it is concluded that: (1) Reliable and safe operation of plants is established by the application of suitable chemical conditions in plant cooling systems, which should be supported by the selection of suitable control targets for monitoring and by the application of reliable instruments. (2) The minimum level of key instrumentation consists of on-line as well as off-line instruments for monitoring the key parameters: - on-line: pH, conductivity, cation conductivity, O{sub 2} and H{sub 2} concentrations, electrochemical corrosion potential; - off-line: radioactive nuclides ({sup 60}Co, {sup 58}Co, {sup 131}I, etc.), and the ...

2010-05-15

94

Disposal of old heads for Daya Bay NPP  

International Nuclear Information System (INIS)

The paper introduces the disposal procedures of the old reactor pressure vessel head. Reactor pressure vessel (RPV) heads were replaced successfully in Daya Bay Nuclear Power Plant. The on-site treatment and disposal of replaced heads was thereafter implemented. This is the first time in China for large size radioactive article disposal. To guarantee the safety of old head treatment, issues of radiation protection have to be taken into account. Dose rate distribution of the old head surface and radioactivity were initially calculated according to the operation history and the neutron flux rate of the reactor. Shielding calculation and package design was thereafter worked out based on the data obtained from the old head, e.g. neutron flux, sorts of nuclides, radioactivity and dose rates. Shielding package was afterwards manufactured in special factories and transported to Daya Bay NPP site by truck and ship. The shielding package was designed relatively simple, ...

95

Activation analysis of trace elements in titanium-molybdate target used for pre-formed TiMo gel based "9"9"mTc generator production and radionuclidic impurity of "9"9"mTc pertechnetate eluate  

International Nuclear Information System (INIS)

A gel-type "9"9Mo-"9"9"mTc generator using Titanium-Molybdate target (TiMo-target) as column packing was developed in Radioisotope Department, the Dalat Nuclear Research Institute [1]. The concentration of trace elements in TiMo-target and radionuclidic purity in "9"9"mTc solution eluted from this type of generator were studied for quality control purpose. The monostandard method in neutron activation analysis has been applied to determine the concentration of trace impurities in titanium-molybdate target. For neutron activation analysis, TiMo samples were irradiated in the different channels of nuclear reactor IVV-9 at a neutron flux of maximum 2.1 x 10"1"3 n.cm"-"2s"-"1. The following chemical element impurities were determined: Na, W, Co, Fe, Zn, Ag, Sb and Cr. The gamma ray emitted nuclides found in "9"9"mTc solution eluted from our "9"9"mTc generator were the following: "6"5Zn, "6"0Co, "1"1"0"mAg, "5"9Fe, "5"1Cr, "2"4Na, "8"2Br and "9"9Mo. "9"9Mo was found ...

2004-06-01

96

#beta#-delayed proton decays near the proton drip line  

International Nuclear Information System (INIS)

The experimental study on #beta#-delayed proton decays near the proton drip line published by our group over the last 8 years were reviewed and summarized briefly, including first observation of 9 precursors in the rare-earth region and new measurements of 5 nuclei in the mass-90 region near N-Z line with the aid of the 'p-#gamma#' coincidence in combination with a He-jet tape transport system. Systematically comparing the experimental data with the current nuclear-model predictions, following points were represented. (1) the experimental half-lives for "8"5Mo and "9"2Rh as well as the predicted 'waiting point' nuclei "8"9Ru and "9"3Pd are 5-10 times longer than the macroscopic-microscopic model predictions given by Moeller et al. It considerably influences the prediction of mass abundances of the nuclides produced in rp-process. (2) The current-model predictions are not consistent with the experimental spin-parity assignments of the proton ...

2004-12-01

97

Traces of evidence. Nuclear forensics and illicit trafficking  

International Nuclear Information System (INIS)

An IAEA databank lists a number of reported cases of illicitly trafficked nuclear or other radioactive materials. Apart from the traditional concern with nuclear proliferation, the post September 11th public is now wary of a possible attack by terrorists with a nuclear or radiation dispersion device (RDD). Until now, the seized quantities have not been sufficient to manufacture a nuclear explosive device, but they might be enough to construct an RDD. Recognizing the latent global challenge to public health and safety, the G8 States (Japan, USA, Germany, France, UK, Italy, Canada, and Russia) have called for 'joint international efforts to identify and suppress illicit supply' of, and demand for, nuclear material and to deter potential traffickers. One measure gaining in significance is to identify seized material and trace it back to its origin the objective of an emerging science known as nuclear forensics. Repeatedly nuclear or other radioactive material of ...

2003-06-01

98

Emission of {sup 14}C by the Almirante Alvaro Alberto Nuclear Power Plant 1 and 2 and their local effects on the environmental levels; Emissao de {sup 14}C pelas unidades 1 e 2 da Central Nuclear Almirante Alvaro Alberto (CNAAA) e seu efeito local nos niveis ambientais  

Energy Technology Data Exchange (ETDEWEB)

{sup 14}C is a is a long-lived beta-emitting nuclide (T{sub 1/2} = 5730 years) produced naturally in the upper atmosphere as a result of reactions between neutrons and stable {sup 14}N({sup 14}N(n,p){sup 14}C). Although in a lesser extent, nuclear power plants produce {sup 14}C as well during their routine operation. Since it is converted in {sup 14}CO{sub 2} and mixed throughout the atmosphere, it is incorporated into plant tissues, via photosynthesis process, and hence in food chain. Because of the biological importance of {sup 14}C and long half-life, it is of interest to quantify the amounts released by nuclear industry. The Brazilian nuclear central named Nuclear Central Admiral Alvaro Alberto (CNAAA) has two nuclear reactors of PWR type in operation, Angra I (657 MWe) and Angra II (1350 MWe), and one under construction, Angra III (1309 MWe PWR). The aim of this study was to determine the strength of the sources and the {sup 14}C content in the environment ...

2006-07-01

99

WIS decontamination factor demonstration test with radioactive nuclides  

Energy Technology Data Exchange (ETDEWEB)

A radioactive Waste Incineration System (WIS) with suspension combustion is noticed as effective volume reduction technology of low level radiactive wastes that are increasing every year. In order to demonstrate the decontamination efficiency of ceramic filter used on WIS, this test has been carried out with the test facilities as joint research of Central Research Institute of Electric Power Industry (CRIEPI) and Sumitomo Heavy Industries, Ltd. Miscellaneous combustible waste and power resin, to which 5 nuclides (Mn-54, Fe-59, Co-60, Zn-65, Cs-137) were added, were used as samples for incineration. As the result of the test, it was verified that Decontamination Factor (DF) of the single stage ceramic filter was usually kept over 10/sup 5/ for every nuclide, and from the results of above DF, over 10/sup 8/ is expected for real commercial plant as a total system. Therefore, it is realized that the off-gas clean up system of the WIS composed of ...

1987-04-01

100

WIS decontamination factor demonstration test with radioactive nuclides  

International Nuclear Information System (INIS)

A radioactive Waste Incineration System (WIS) with suspension combustion is noticed as effective volume reduction technology of low level radiactive wastes that are increasing every year. In order to demonstrate the decontamination efficiency of ceramic filter used on WIS, this test has been carried out with the test facilities as joint research of Central Research Institute of Electric Power Industry (CRIEPI) and Sumitomo Heavy Industries, Ltd. Miscellaneous combustible waste and power resin, to which 5 nuclides (Mn-54, Fe-59, Co-60, Zn-65, Cs-137) were added, were used as samples for incineration. As the result of the test, it was verified that Decontamination Factor (DF) of the single stage ceramic filter was usually kept over 10"5 for every nuclide, and from the results of above DF, over 10"8 is expected for real commercial plant as a total system. Therefore, it is realized that the off-gas clean up system of the WIS composed of only single ...

101

Re-evaluation of neutron nuclear data for {sup 242m}Am, {sup 243}Am, {sup 99}Tc and{sup 140}Ce  

Energy Technology Data Exchange (ETDEWEB)

The evaluated nuclear data given in JENDL-3.2 were compared with other evaluated data sets and available experimental data, for important minor actinides of {sup 242m}Am and {sup 243}Am, and fission product nuclides of {sup 99}Tc and {sup 140}Ce. Since problems were found as a result of the comparison, the data of JENDL-3.2 were improved for these nuclides. It was found that the evaluated data of Maslov et al. were superior to the others. They were adopted for {sup 242m}Am and {sup 243}Am after further improvements. For {sup 99}Tc and {sup 140}Ce, resonance parameters and optical model parameters were improved. The cross sections of these two nuclides in the smooth part were re-calculated. The present results were given in the neutron energy range from 10{sup -5} eV to 20 MeV in the ENDF-6 format, and adopted to JENDL-3.3. (author)

2002-12-01

102

Distribution of "2"3"0Th in milling wastes from the Zirovski vrh uranium mine (Slovenia), and its radioecological implications  

International Nuclear Information System (INIS)

Thorium-230, together with "2"3"8U and "2"2"6Ra, was determined (mainly by #gamma#-spectrometry) in samples from the waste piles at Borst and Jazbec in the vicinity of the former uranium mine at Zirovski vrh, Slovenia. Activity (and in the case of uranium, also mass) balances for these nuclides were constructed for the overall operation of the mine and yellow cake plant, using experimental data and known data on ore and uranium production, and nuclide emissions to the environment. All the "2"2"6Ra resulting from ore exploitation is presently contained in the Borst tailings pile. However, because of the very high content of "2"3"0Th in red mud deposited at Jazbec, where 60% of this nuclide is found, the majority of "2"2"6Ra will be found at the Jazbec pile in the future, due to its ingrowth from "2"3"0Th over the next few thousand years. (Author).

103

Total and spontaneous fission half-lives for americium and curium nuclides  

Science.gov (United States)

The long-lived nuclides of the americium curium elements are of interest for their use in certain safeguard applications and for nuclear reactor burnup studies in waste management. Recommended values are presented for /sup 241,242m,243/Am, and for /sup 242,243,244,245,246,247,248,250/Cm. These values result from a consistent evaluation of all these half-lives. These preliminary estimates were presented earlier. The uncertainties are provided at the 95% confidence limit for each of the recommended values. It will be noted that many of the recommended errors considerably exceed errors quoted by individual authors in their publication, by up to an order of magnitude, e.g., the total half-life of /sup 242,246,248/Cm and the spontaneous fission half-life of /sup 244/Cm. 65 refs., 18 tabs.

1985-01-01

104

Thermal neutron capture gamma-rays  

Energy Technology Data Exchange (ETDEWEB)

The energy and intensity of gamma rays as seen in thermal neutron capture are presented. Only those (n,..cap alpha..), E = thermal, reactions for which the residual nucleus mass number is greater than or equal to 45 are included. These correspond to evaluations published in Nuclear Data Sheets. The publication source data are contained in the Evaluated Nuclear Structure Data File (ENSDF). The data presented here do not involve any additional evaluation. Appendix I lists all the residual nuclides for which the data are included here. Appendix II gives a cumulated index to A-chain evaluations including the year of publication. The capture gamma ray data are given in two tables - the Table 1 is the list of all gamma rays seen in (n,..gamma..) reaction given in the order of increasing energy; the Table II lists the gamma rays according to the nuclide.

1983-01-01

105

Gamma-ray spectrometric analysis of nuclides formed in thorium by neutron irradiation  

International Nuclear Information System (INIS)

Gamma-ray spectrometric analysis was employed to determine the nuclides formed in thorium by neutron irradiation. Thorium sample was irradiated by neutron from a pure thermal neutron field, neutron field of Cd ratio of about 4, and epithermal neutron field, respectively. The former irradiation was carried out in a thermal neutron column provided for medical uses of neutrons, and the latters were done in the F-ring position of TRIGA II research reactor of Musashi Institute of Technology. The gamma-ray spectra were obtained and analyzed by employing a fully automatic gamma-ray analysis system named ''GAMA: giant frog:-SYSTEM'' developped by Musashi Institute of Technology. The formation of Pa-233 (U-233) was discussed quantitatively with respect to the difference of the neutron field. (author).

1985-02-01

106

Isolation and determination of {sup 90}Sr, {sup 226}Ra, {sup 228}Ra and {sup 210}Pb in food; Abtrennung und Bestimmung von {sup 90}Sr, {sup 226}Ra, {sup 228}Ra und {sup 210}Pb in Lebensmitteln mittels eines Strontium-spezifischen Extraktionsharzes  

Energy Technology Data Exchange (ETDEWEB)

A procedure is described for the isolation and determination of {sup 90}Sr, {sup 226}Ra, {sup 228}Ra and {sup 210}Pb in food. These nuclides are highly radiotoxic, above all for babies and children. Samples are dry ashed, alkali metals are removed as carbonates. Separation from other matrix ions and separation of Ra, Sr and Pb can be achieved with a column of Sr-Spec, an immobilized crown ether. For activity measurements membrane filters with SrSO{sub 4}, Ba(Ra)SO{sub 4} and PbS are prepared. Ra is determined by gamma-spectrometry, {sup 90}Sr and {sup 210}Pb are determined by low-level-betacounting. The determination limits are 10 mBq/kg for {sup 90}Sr and {sup 210}Pb and 50 mBq/kg for {sup 226}Ra and {sup 228}Ra. The procedure is useful for all kinds of foodstuff. (orig.) [Deutsch] Es wird ein Analysengang zur Abtrennung und Bestimmung von {sup 90}Sr, {sup 226}Ra, {sup 228}Ra und {sup 210}Pb in Lebensmitteln beschrieben. Ein Merkmal dieser ...

1996-12-31

107

An integrated Tomographic Gamma Scanning system for non-destructive assay of radioactive waste  

Energy Technology Data Exchange (ETDEWEB)

The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm{sup -3} or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant applications. Many of the design features and the end application itself set these TGS ...

2007-08-21

108

An integrated Tomographic Gamma Scanning system for non-destructive assay of radioactive waste  

International Nuclear Information System (INIS)

The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm"-"3 or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant applications. Many of the design features and the end application itself set these TGS systems ...

2007-08-21

109

Simulations of Groundwater Flow and Radionuclide Transport in the Vadose and Saturated Zones beneath Area G, Los Alamos National Laboratory  

Energy Technology Data Exchange (ETDEWEB)

Numerical simulations are used to predict the migration of radionuclides from the disposal units at Material Disposal Area G through the vadose zone and into the main aquifer in support of a radiological performance assessment and composite analysis for the site. The calculations are performed with the finite element code, FEHM. The transport of nuclides through the vadose zone is computed using a three-dimensional model that describes the complex mesa top geology of the site. The model incorporates the positions and inventories of thirty-four disposal pits and four shaft fields located at Area G as well as those of proposed future pits and shafts. Only three nuclides, C-14, Tc-99, and I-129, proved to be of concern for the groundwater pathway over a 10,000-year period. The spatial and temporal flux of these three nuclides from the vadose zone is applied as a source term for the three-dimensional saturated zone model of the ...

1999-07-01

110

PRESTO-PREP: a data preprocessor for the PRESTO-II code  

Energy Technology Data Exchange (ETDEWEB)

PRESTO-II is a computer code developed to evaluate possible health effects from shallow land disposal of low level radioactive wastes. PRESTO-PREP is a data preprocessor that has been developed to expedite the formation of input data sets for PRESTO-II. PRESTO-PREP utilizes a library of nuclide and risk-specific data. Given an initial waste inventory, the code creates the radionuclide portion of the associated input data set for PRESTO-II. 2 references.

1984-07-01

111

Contamination preventive method and decontaminating method for equipment  

Energy Technology Data Exchange (ETDEWEB)

The method of the present invention comprises a step of previously coating a positive type resist on the surface of equipment, a step of solidifying the coated positive type resist and a step of bringing the coated equipment to circumstances for use and cleaning the positive type resist. With such procedures, the amount of radioactive materials deposited on the equipment can be reduced, and redeposition of nuclides on the surface to be cleaned can be prevented. (T.M.)

1998-12-04

112

Brain and bone scans in primary Ewing's sarcoma of the petrous bone: case report  

International Nuclear Information System (INIS)

The authors present a case in which primary Ewing's sarcoma of the right petrous pyramid in a 9-year-old girl showed no uptake on a /sup 99m/Tc-pertechnetate nuclide angiogram. Intense uptake was present on a /sup 99m/Tc-polyphosphate bone scan, but a static brain scan was only minimally abnormal. The diagnosis and treatment of Ewing's sarcoma are reviewed.

113

An experimental plan for improvement of failed fuel monitoring system in CANDU reactor  

Energy Technology Data Exchange (ETDEWEB)

An experimental plan for improving the problems of failed fuel location system in Wolsung Unit-2 reactors was established. It is not possible to make an experiment on the failed fuel monitoring nuclides in the cold laboratories because they have very short half life. Therefore, the experiments can be only carried out at the existing monitoring system under reactor operation. For that reason, an experimental plan was drawn up for installing the radiation detection system on reactor site.

2003-10-01

114

Recovery of uranium from uranium and lanthanides in LiCl-KCl molten salt by electrowinning including Cd-Li anode  

Energy Technology Data Exchange (ETDEWEB)

A trans-uranium (TRU) fuel should be manufactured and loaded in transmutation systems in order to transmute the long-lived TRU nuclides into short-lived ones. However, since all of the TRU nuclides are not completely transmuted in one cycle lifetime in transmutation systems, the spent TRU fuel has to be treated to recover the long-lived radionuclides or fuel matrix materials. One concept to manufacture TRU fuel for transmutation is to recover uranium from TRU and molten salt. If this type of fuel is adopted for transmutation, uranium could also be an objective material to be recovered and recycled. Since electrowinning is a promising technology to be employed for the recovery of uranium from fuel materials, some experimental work of electrowinning using anode of Cd-Li alloy was carried out in this study. The basic salt chosen was a mixture of LiCl-KCl which has an eutectic point at 357 .deg. C.

2005-07-01

115

Recovery of uranium from uranium and lanthanides in LiCl-KCl molten salt by electrowinning including Cd-Li anode  

International Nuclear Information System (INIS)

A trans-uranium (TRU) fuel should be manufactured and loaded in transmutation systems in order to transmute the long-lived TRU nuclides into short-lived ones. However, since all of the TRU nuclides are not completely transmuted in one cycle lifetime in transmutation systems, the spent TRU fuel has to be treated to recover the long-lived radionuclides or fuel matrix materials. One concept to manufacture TRU fuel for transmutation is to recover uranium from TRU and molten salt. If this type of fuel is adopted for transmutation, uranium could also be an objective material to be recovered and recycled. Since electrowinning is a promising technology to be employed for the recovery of uranium from fuel materials, some experimental work of electrowinning using anode of Cd-Li alloy was carried out in this study. The basic salt chosen was a mixture of LiCl-KCl which has an eutectic point at 357 .deg. C

2005-05-26

116

Development of a process for the disposal of evaporation residues from NPP by precipitation/flocculation and solidification of the precipitation products. Final report  

International Nuclear Information System (INIS)

To reduce the volume of radioactive wastes after evaporation, activity carriers can be separated from the inactive salt load. Boric acid separation from PWR concentrates was considered a preliminary stage for nuclide precipitation. In connection with the precipitation process, the reaction conditions for boric acid separation were determined by bench-scale experiments. After evaluating the known purification processes, crystallization was suggested as a practicable method. After inactive bench-scale experiments, mixed crystal formation with iron hexacyanoferrate for Cs removal was chosen. The disturbing effect of the complexing agents was neutralized by a pre-dose of iron-III-salts. By specifying the precipitation conditions, for Cs-134 an activity separation from 3,0 E + 06 Bg/l to 1,9 E + 02 Bg/l, and for Cs-137 from 5,9 E + 06 Bg/l to 1,2 E + 02 Bg/l was achieved. Accordingly, the decontamination factor for Cs-134 was 16000, and for Cs-137 48000. For the ...

117

Alpha-particle autoradiography in Cr-39. The determination of the microdistribution of activity and trace element analysis  

Energy Technology Data Exchange (ETDEWEB)

New and elaborate techniques for alpha-particle autoradiography of thick specimens based on the plastic nuclear track detector CR-39 have been developed. These permit a full analysis of both trace element and microdistribution of alpha-active nuclides present. The important features of the techniques are: 1) reliable low level configuration down to 10/sup -15/ Ci g/sup -1/, 2) high resolution alpha-particle spectroscopy in CR-39, 3) determination of the absolute abundance of alpha active nuclides present in the specimen, 4) determination of the distribution of emission with height up to 30 microns above the surface of the autoradiograph, 5) the local determination of the radon diffusion coefficient in the specimen which is needed to calculate the activity levels of /sup 222/Rn and daughter nuclei, 6) the analysis of small and large clusters of alpha-particle activity recorded on the autoradiograph. These techniques are briefly discussed.

1984-06-15

118

Acceptable requirement of decontamination factor for LLW disposal of PEACER pyro-processing wastes  

International Nuclear Information System (INIS)

A pyrochemical process has been introduced and utilized so that the transmutation of spent PWR fuel in PEACER can produce mainly low and intermediate level waste for near surface disposal. Major radioactive nuclides from PEACER pyro-processing are composed of TRU and LLFP. In this study, the requirement for the final waste from PEACER is evaluated based on the methodology for establishment of waste acceptance criteria. Also, sensitivity analysis for several input parameters is conducted in order to determine acceptable decontamination factor (DF) and LLFP removal efficiency and to find out input parameter that extremely have an effect on DF. As a result of the study, LLFP removal efficiency, especially Sr-90 and Tc-99, is proved to be a major nuclide which contributes to annual dose by human intrusion scenario rather than TRU DF. More than 98.5% of LLFP have to be removed to meet below dose constraint within the DF more than 5.0E+03. Besides, ...

2007-09-09

119

Acceptable decontamination factor for near-surface disposal of PEACER wastes  

Energy Technology Data Exchange (ETDEWEB)

A pyrochemical process has been introduced and utilized so that the transmutation of spent PWR fuel in PEACER can produce mainly low and intermediate level waste for near surface disposal. Major radioactive nuclides from PEACER pyroprocessing are composed of TRU and LLFP. In this study, the requirement for the final waste from PEACER is evaluated based on the methodology for establishment of waste acceptance criteria. Also, sensitivity analysis for several input parameters is conducted in order to determine acceptable decontamination factor (DF) and LLFP removal efficiency and to find out input parameter that extremely have an effect on DF. As a result of the study, LLFP removal efficiency, especially Sr-90 and Tc-99, is proved to be a major nuclide which contributes to annual dose by human intrusion scenario rather than TRU DF. More than 98.5% of LLFP have to be removed to meet below dose constraint within the DF more than 5.0E + 03. Besides, ...

2005-11-15

120

Acceptable decontamination factor for near-surface disposal of PEACER wastes  

International Nuclear Information System (INIS)

A pyrochemical process has been introduced and utilized so that the transmutation of spent PWR fuel in PEACER can produce mainly low and intermediate level waste for near surface disposal. Major radioactive nuclides from PEACER pyroprocessing are composed of TRU and LLFP. In this study, the requirement for the final waste from PEACER is evaluated based on the methodology for establishment of waste acceptance criteria. Also, sensitivity analysis for several input parameters is conducted in order to determine acceptable decontamination factor (DF) and LLFP removal efficiency and to find out input parameter that extremely have an effect on DF. As a result of the study, LLFP removal efficiency, especially Sr-90 and Tc-99, is proved to be a major nuclide which contributes to annual dose by human intrusion scenario rather than TRU DF. More than 98.5% of LLFP have to be removed to meet below dose constraint within the DF more than 5.0E + 03. Besides, ...

2005-11-01

121

Inter-comparison of some environmental radioactivity monitoring items for Guangdong Daya Bay Nuclear Power Plant  

International Nuclear Information System (INIS)

This paper introduces the inter-comparison results of some environmental radioactivity monitoring items for Daya Bay nuclear power plant. The inter-comparison was organized by China Institute for Radiation Protection and five laboratories participated in it. The compared items included total #beta# in kelp and sediment, "3H in water, "9"0Sr in soil, artificial nuclides "1"1"0"mAg, "2"4"1Am, "1"0"9Cd, "5"7Co in kelp and sediment. Inter-comparison results are analyzed as well

2003-01-01

122

Decontamination of building surface using clay suspension  

Energy Technology Data Exchange (ETDEWEB)

The decontamination of the urban building surfaces, based on the covering of clay suspensions, has been studied. Contaminated samples for test purpose were prepared by application of radioactive solution which was extracted from the soil of 2 km zone of the Chernobyl Nuclear Power Plant(ChNPP). The cation converting conditions of clay suspensions were determined by the experiments of swelling and stability of the suspensions. According to the experimental results, the most effective clay suspension was the NH{sub 4}-type which had a 7.1 of decontamination factor(DF) on Cs and 4.5 of DF on total nuclides after 3 times covering on slate.

1994-07-01

123

{beta}-delayed proton decays near the proton drip line  

Science.gov (United States)

We briefly reviewed and summarized the experimental study on {beta}-delayed proton decays published by our group over the last 8 years, namely the experimental observation of {beta}-delayed proton decays of nine new nuclides in the rare-earth region near the proton drip line and five nuclides in the mass 90 region with N{approx}Z by utilizing the p-{gamma} coincidence technique in combination with a He-jet tape transport system. In addition, important technical details of the experiments were provided. The experimental results were compared to the theoretical predictions of some nuclear models, resulting in the following conclusions. (1) The experimental half-lives for {sup 85}Mo, {sup 92}Rh, as well as the predicted 'waiting point' nuclei {sup 89}Ru and {sup 93}Pd were 5-10 times longer than the macroscopic-microscopic model predictions of Moeller et al. [At. Data Nucl. Data Tables 66,131(1997)]. These data considerably ...

2005-05-01

124

Study on immobilizing radioactive slurry based on alkali-activated slag-clay minerals composite cement  

International Nuclear Information System (INIS)

The feasibility of immobilizing simulated radioactive slurry (SRS) by alkali-activated slag---clay minerals composite cement (AASCM) was studied under the experimental conditions. The results show that the dosage of SRS and water cement ratio (W/C) have significant effect on the flowability of the mixture of AASCM and SRS. The more dosage of SRS, the lower flowability. When cement/sand ratio is 1: 1 and W/C is 0.45, the flowability of the mixture meets the case of solidification engineering and the compressive strength of the waste forms containing 20% SRS meets the needs of GB 14569.1-93. The setting time of the mixture of AASCM and SRS is highly dependent on temperature while sorts of anions have little influence on it. The application of AASCM is suitable below 20 degree C. The leaching resistance of AASCM based waste forms is superior to that of OPC based waste forms. The control of the forms to Sr2+ is stronger than that to Cs+. Silicon fume can improve workability of the mixture ...

2006-03-01

125

Study of radionuclide contributing to dose rates in 540 MWe plant environment  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station Unit-4 is first 540 MWe pressurized heavy water reactor in India. It achieved criticality on 06th March 2005 and then operated at full power i.e 500 MWe. Radiation workers during the normal operation and reactor shutdown are exposed to radiation field. The control of dose rates and the collective dose of the radiation workers is most important for the best performance of the reactor. Experience gained during the operation of the 220 MWe reactors has shown that the Moderator system, primary heat transport system, annulus gas system and moderator cover gas system are the main systems contributing to the dose rate and collective dose. In order to identify the radio nuclides contributing to the radiation field, study was undertaken at TAPS Unit-4. Various samples from the Moderator, primary heat transport system, annulus gas system and moderator cover gas system were collected and analysed for the spectrometric analysis. This paper ...

2005-11-23

126

Reprocessed uranium fuel fabrication in Japan  

International Nuclear Information System (INIS)

Nuclear fuel vendors in Japan are now studying reprocessed uranium (RepU) fuel in order to prepare for full scale utilization in the future. Separate studies are made for PWR and BWR fuel. The study consists of 2 phrases. The purposes of phase-1 are to understand various RepU characteristics in the fuel fabrication process, to analyze the core characteristics by loading RepU assemblies, to solve the problems clarified in the study, and to collect basic data for licensing. In phase-2, the effects of impurities on the fabrication process will be evaluated, and the safety of RepU fuel manufacturing will be confirmed with a RepU fuel fabrication campaign in 1990. The neutronic data will be collected after insertion into power reactors, and the data will be used to verify plant safety for full utilization of RepU in the future. This paper summarizes the phase-1 study results. 1. RepU Characteristics. The internal and external radiation exposures due to nuclide ...

1990-12-01

127

Re-evaluation of neutron nuclear data for sup 2 sup 4 sup 2 sup m Am, sup 2 sup 4 sup 3 Am, sup 9 sup 9 Tc and sup 1 sup 4 sup 0 Ce  

CERN Document Server

The evaluated nuclear data given in JENDL-3.2 were compared with other evaluated data sets and available experimental data, for important minor actinides of sup 2 sup 4 sup 2 sup m Am and sup 2 sup 4 sup 3 Am, and fission product nuclides of sup 9 sup 9 Tc and sup 1 sup 4 sup 0 Ce. Since problems were found as a result of the comparison, the data of JENDL-3.2 were improved for these nuclides. It was found that the evaluated data of Maslov et al. were superior to the others. They were adopted for sup 2 sup 4 sup 2 sup m Am and sup 2 sup 4 sup 3 Am after further improvements. For sup 9 sup 9 Tc and sup 1 sup 4 sup 0 Ce, resonance parameters and optical model parameters were improved. The cross sections of these two nuclides in the smooth part were re-calculated. The present results were given in the neutron energy range from 10 sup - sup 5 eV to 20 MeV in the ENDF-6 format, and adopted to JENDL-3.3.

2002-01-01

128

#beta#-delayed proton decays near the proton drip line  

International Nuclear Information System (INIS)

We briefly reviewed and summarized the experimental study on #beta#-delayed proton decays published by our group over the last 8 years, namely the experimental observation of #beta#-delayed proton decays of nine new nuclides in the rare-earth region near the proton drip line and five nuclides in the mass 90 region with N#approx#Z by utilizing the p-#gamma# coincidence technique in combination with a He-jet tape transport system. In addition, important technical details of the experiments were provided. The experimental results were compared to the theoretical predictions of some nuclear models, resulting in the following conclusions. (1) The experimental half-lives for "8"5Mo, "9"2Rh, as well as the predicted 'waiting point' nuclei "8"9Ru and "9"3Pd were 5-10 times longer than the macroscopic-microscopic model predictions of Moeller et al. [At. Data Nucl. Data Tables 66,131(1997)]. These data considerably influenced the predictions of the mass ...

2005-05-01

129

Contaminant transport in fracture networks with heterogeneous rock matrices. The Picnic code  

Energy Technology Data Exchange (ETDEWEB)

In the context of safety assessment of radioactive waste repositories, complex radionuclide transport models covering key safety-relevant processes play a major role. In recent Swiss safety assessments, such as Kristallin-I, an important drawback was the limitation in geosphere modelling capability to account for geosphere heterogeneities. In marked contrast to this limitation in modelling capabilities, great effort has been put into investigating the heterogeneity of the geosphere as it impacts on hydrology. Structural geological methods have been used to look at the geometry of the flow paths on a small scale and the diffusion and sorption properties of different rock materials have been investigated. This huge amount of information could however be only partially applied in geosphere transport modelling. To make use of these investigations the 'PICNIC project' was established as a joint cooperation of PSI/Nagra and QuantiSci to provide a new geosphere transport ...

2001-02-01

130

ZZ DECAYREM/C, Decay Spectra Library for EXREM Calculation  

International Nuclear Information System (INIS)

Description of problem or function: Format: EXREM III; Nuclides: radioactive decay data on 252 Nuclides: 1H-3, 4Be-7, 6C-11, 6C-14, 7N-13, 8O-15, 9F-18, 11Na-22, 11Na-24, 12Mg-28, 13Al-28, 15P-32, 15P-33, 16S-35, 17Cl-36, 17Cl-38, 18A-37, 18A-39, 19K-40, 19K-42, 19K-43, 20Ca-45, 20Ca-47, 20Ca-49, 21Sc-46, 21Sc-47, 21Sc-49, 24Cr-51, 25Mn-52M, 25Mn-52, 25Mn-54, 26Fe-52, 26Fe-55, 26Fe-59, 27Co-56, 27Co-57, 27Co-58, 27Co-60, 28Ni-56, 28Ni-63, 29Cu-64, 30Zn-65, 30Zn-69M, 30Zn-69, 31Ga-67, 31Ga-68, 32Ge-77, 33As-76, 33As-77, 34Se-75, 35Br-80M, 35Br-80, 35Br-82, 35Br-83, 35Br-84, 36Kr-79, 36Kr-83M, 36Kr-85M, 36Kr-85, 36Kr-87, 36Kr-88, 37Rb-84, 37Rb-86, 37Rb-87, 37Rb-88, 37Rb-89, 37Rb-90M, 37Rb-90, 38Sr-85, 38Sr-87M, 38Sr-89, 38Sr-90, 38Sr-91, 38Sr-92, 38Sr-93, 39Y-87, 39Y-88, 39Y-90, 39Y-91M, 39Y-91, 39Y-92, 39Y-93, 40Zr-93, 41Nb-93M, 40Zr-95, 40Zr-97, 41Nb-95M, 41Nb-95, 41Nb-97M, 41Nb-97, 42Mo-99, 43Tc-99M, 43Tc-99, 44Ru-103, 44Ru-105, 44Ru-106, ...

131

The Path to Metallicity: Synthesis of CNO Elements inStandard BBN  

Energy Technology Data Exchange (ETDEWEB)

We perform an analysis of the production of elements with mass number A {ge} 12 in a standard Big Bang Nucleosynthesis scenario. The goal is to provide a more accurate estimate of the very low and yet poorly explored abundance of such elements, relevant for the pristine Population III stars. We examine the synthesis channels for these elements in a critically revised and updated version of the Wagoner-Kawano code, as well as in a further enlarged version including four additional nuclides and a significantly extended nuclear network. Our results show no major discrepancies with the ones obtained using a smaller nuclear network. The robustness of the standard predictions--the early generation of star developed in a metal-free environment--is confirmed.

2007-02-12

132

Shell-model calculations for neutron-rich nuclei in the 0f1p shell  

Energy Technology Data Exchange (ETDEWEB)

A new two-body interaction recently derived for nuclei in the 0f1p shell by fitting two-body matrix elements to 494 energy levels in A=41-66 nuclei, is used to investigate the neutron-rich nuclei in the vicinity of the doubly closed nuclide {sup 48}Ca. This study is of fundamental interest in providing a test for the new effective interaction away from the stability line. Masses and binding energies are calculated for a variety of neutron-rich nuclei and compared with experimental data, where available. In addition level schemes for {sup 50-52}Ca, {sup 51-52}Sc and {sup 51-52}Ti have been calculated and are compared with available experimental data. In general a good correspondence between theory and experiment is found, but some systematic discrepancies are apparent. ((orig.)).

1995-04-17

133

Shell-model calculations for neutron-rich nuclei in the 0f1p shell  

International Nuclear Information System (INIS)

A new two-body interaction recently derived for nuclei in the 0f1p shell by fitting two-body matrix elements to 494 energy levels in A=41-66 nuclei, is used to investigate the neutron-rich nuclei in the vicinity of the doubly closed nuclide "4"8Ca. This study is of fundamental interest in providing a test for the new effective interaction away from the stability line. Masses and binding energies are calculated for a variety of neutron-rich nuclei and compared with experimental data, where available. In addition level schemes for "5"0"-"5"2Ca, "5"1"-"5"2Sc and "5"1"-"5"2Ti have been calculated and are compared with available experimental data. In general a good correspondence between theory and experiment is found, but some systematic discrepancies are apparent. ((orig.)).

134

Requirement of decontamination factor for near-surface disposal of PEACER wastes  

International Nuclear Information System (INIS)

A pyrochemical process has been introduced and utilized so that the transmutation of spent PWR fuel in PEACER can produce mainly low and intermediate level waste for near surface disposal. Major radioactive nuclides from PEACER pyroprocessing are composed of TRU and LLFP. In this study, the requirement for the final waste from PEACER is evaluated based on the methodology for establishment of waste acceptance criteria. Also, sensitivity analysis for several input parameters is conducted in order to determine acceptable decontamination factor (DF) and LLFP removal efficiency and to find out input parameter that extremely have an effect on DF. As a result of the study, TRU DF and LLFP removal efficiency have to be achieved more than 1.0E+04 - 1.0E+05 and 96%, respectively. (author)

2005-10-09

135

Proposal of the research complex for the neutron science (The first plan)  

Energy Technology Data Exchange (ETDEWEB)

Japan Atomic Energy Research Institute (JAERI) is developing the world`s strongest spallation neutron source using high power proton accelerator and promoting a neutron science project for comprehensive studies on basic science and nuclear transmutation of high-level radioactive nuclide from nuclear power stations. For this purpose, JAERI organized the Special Taskforce for Neutron Science and OMEGA Project in April 1996 and reorganized it to Center for Neutron Science in April 1997. During this period, various research plans using the spallation neutron source are proposed and facilities necessary for research are studied by mainly research groups of JAERI. This report describes research plans and results of the preliminary conceptual design study on proposed facilities plan. (author)

1999-03-01

136

Precise radiometry: Some recent aspects of fruitful interaction with atomic physics  

International Nuclear Information System (INIS)

Modern radiometric analytics demands a complex consideration of nuclear and electron shell processes, if more pretentious aims are envisaged. As an example the small variation of decay rates of radionuclides presents possibilities for information on chemical situations of decaying atoms. In principle this phenomenon is well known since many years, but now the situation is such that, e.g. in /sup 99m/Tc internal conversion, a full agreement of the difficult experiments and the respective theory was established. The secondary emission of X-rays as a consequence of high excitation of electron shells in combination with nuclear transitions supplies another example for a methodical progress of radiometry. Investigations on "5"1Cr as an electron capture nuclide have shown that chemically induced variations of the K/sub #alpha#/ to K/sub #beta#/ X-ray intensity ratio is at least qualitatively understood. (author).

1986-01-01

137

Nuclear astrophysics with radioactive ion beams  

International Nuclear Information System (INIS)

Nuclear astrophysics seeks for a possible explanation of the observed abundance distribution of various elements and their isotopes in the universe. Most of the relevant nuclear reactions take place in thermally equilibrium environments with bare nuclei, rather than accelerated and head-on colliding situations with low ionisation states of reactant atoms and molecules that are emulated in the laboratories. Moreover, the temperature of the astrophysical environments is quite often low compared to the centre-of-mass energy of the projectile nuclides, that is required for the reaction to be meaningfully investigated in the laboratory. Therefore, an extrapolation of the data on the reaction cross sections to very low energies and to extremely high density situations is generally called for, which are substantially altered every now and then for a number of astrophysically important reactions. The radioactive ion beams will provide us important data on some of those ...

138

Novel, convenient, and nonpersistent radiotracer for environmental and energy applications  

Energy Technology Data Exchange (ETDEWEB)

A newly-available radioisotopic system, /sup 172/Hf-/sup 172/Lu, has excellent potential for tracer applications in which nuclear data acquisition must be accomplished in real time. The 6.7-day half-life of /sup 172/Lu is sufficient for a large fraction of tracer experiments, and should allow the direct incorporation of /sup 172/Lu into tests that have traditionally utilized much longer-lived radionuclides. Since /sup 172/Lu is the daughter component of a radioisotope generator, however, its effective shelf-life is determined by the half-life of its 1.9-year /sup 172/Hf parent. Consequently, the frequency of isotope procurement need not be any more extensive than investigators would normally be accustomed to. Discussion relevant to isotope production, generator operation, and nuclide acquisition is presented in this paper.

1984-03-12

139

Nigeria's radioactive waste management policy and strategy document  

International Nuclear Information System (INIS)

Radioactive waste for legal and regulatory purposes may be defined as material that contains or is contaminated with radio-nuclides at concentrations or activities greater than clearance levels as established by the regulatory body, and for which no use is foreseen. Safe management of radioactive waste is essential to ensure protection of humans and environment. Radioactive waste management policy is a guideline for the safe management of radioactive waste. It expresses the commitment of the country towards the goal. Government should initiate investigation into best long-term option for management of spent nuclear fuels. Process of selecting option and eventual site should involve comprehensive public participation within set time frames (with deep geological disposal as preferred management option).

2009-07-14

140

Leaching characteristics of paraffin waste package with pinhole  

International Nuclear Information System (INIS)

An Effect of pinhole(perforation or pit penetration) that might be formed outside the package on the nuclide leaching from paraffin waste form was investigated. In case of single pinhole, the leached mass and cumulative fraction leached (CFL) increased with the larger diameter of pinhole, but they were not in direct proportion to the size or area of pinhole. If the total area of multiple pinholes was fixed, the leached mass showed a tendency to increase as each size was smaller and the number was more. It was also found that the leached mass was not in direct proportion to the number of pinhole in case of constant size. In order to analyze the test results, the shrinking core model(SCM) was derived from the diffusion-controlled dissolution reaction and compared with previous diffusion model.

2001-05-01

141

Improvements on burnup chain model and group cross section library in the SRAC system  

Energy Technology Data Exchange (ETDEWEB)

Data and functions of the cell burnup calculation of the SRAC system were revised to improve mainly the accuracy of the burnup calculation of high conversion light water reactors (HCLWRs). New burnup chain models were developed in order to treat fission products (FPs) and actinide nuclides in detail. Group cross section library, SRACLIB-JENDL2, was generated based on JENDL-2 nuclear data file. In generating this library, emphasis was placed on FPs and actinides. Also revised were the data such as the average energy release per fission for various actinides. These improved data were verified by performing the burnup analysis of PWR spent fuels. Some new functions were added to the SRAC system for the convenience to yield macroscopic cross sections used in the core burnup process. (author).

1992-01-01

142

Experiences of simulated tracer dispersal studies using effluent discharges at Tarapur aquatic environment  

International Nuclear Information System (INIS)

The nuclear complex in Tarapur, Maharashtra is a multi facility nuclear site comprising of power reactors and research facilities. Each facility has independent liquid effluent discharge line to Arabian Sea. Experimental studies were conducted to evaluate dilution factors in the aquatic environment using liquid effluent releases as tracer from one of the facilities. 3H and 137Cs radioisotopes present in the routine releases were used as simulated tracer nuclides. The dilution factors(D.F) observed for tritium were in the range of 20-20000 in a distance range of 10 m to 1500 m respectively and for 137Cs the D.F. were in the range of 50 to 900 over a distance range of 10-200 m. The paper describes the analytical methodology and sampling scenarios and the results of dilution factors obtained for Tarapur aquatic environment. (author)

2007-06-05

143

Evaluation of the long-term mechanical behavior in the near-fields considering chemical transitions of barrier materials  

International Nuclear Information System (INIS)

An analysis system for the long-term mechanical behavior of barrier materials (MACBECE: Mechanical Analysis system considering Chemical transitions of BEntonite-based and CEment-based materials) was developed in order to improve the reliability of the evaluation of the hydraulic field which is one of the important environmental conditions in the safety assessment of the TRU waste disposal. MACBECE is the system that calculates the deformation of barrier materials using their chemical property changes as inputs, and subsequently calculates their hydraulic conductivity taking both their chemical property changes and deformation into consideration. By using MACBECE, the long-term deformation and the transition of hydraulic field for the round-type disposal cavities were evaluated, assuming some sets of chemical evolution data as input. Based on the analysis result, it is considered that the influence of the long-term deformation of the barrier materials on the nuclide ...

2007-04-22

144

Comparison of sodium zirconium phosphate and Synroc matrices for immobilization of high-level waste  

Energy Technology Data Exchange (ETDEWEB)

The aims of the present work were to investigate possible compatibility between sodium zirconium phosphate (NZP) and Synroc titanate phases, to prepare NZP-based waste forms by hot-pressing rather than sintering, and to investigate the incorporation in NZP of (a) Cs/Sr as simulated heat-generating nuclides; (b) simulated actinides; and (c) simulated Purex waste. The NZP samples were prepared by methods similar to those used for Synroc. The precursor NZP phase was formed from tetrabutyl zirconate Zr(OC{sub 4}H{sub 9}){sub 4}, sodium nitrate, and 85% orthophosphoric acid. Simulated waste nitrate solutions were then mixed with the liquid precursor. After stir drying of the precursor, calcination was carried out at 700{degree}C to remove nitrates and organics.

1996-12-31

145

Age determination of meteorites using radioactive nuclides  

Energy Technology Data Exchange (ETDEWEB)

Recently, the precise isotope ratios of some refractory elements in meteorites have been reported using inductively coupled plasma mass spectrometry. The in situ decay of {sup 182}Hf (T{sub 1/2}=9 Myr), which was produced at the latest nucleosynthesis, is recognized in many meteorites as isotopic anomalies of its daughter isotope, {sup 182}W. The degrees of relative {sup 182}W isotopic deviation in extra-terrestrial and terrestrial silicate samples vary from +0.3% to {+-}0% related to the size of their parent bodies. One ready interpretation of its correlation is the difference in timing of metal-silicate separation in the parent bodies. Between the earth and meteorite parent bodies, the difference is calculated to be about four times of the half-life of {sup 182}Hf, equivalent to 36 Myr. (author)

2002-07-01

146

Adsorption behavior of strontium on kaolinite and montmorillonite and their mixtures  

Energy Technology Data Exchange (ETDEWEB)

{sup 90}Sr, with a long half-life of 28.5 years, is the most dangerous strontium isotope. The adsorption behavior of radionuclides in the environment are closely related to the safe disposal of radioactive wastes. Since various types of minerals may exist in and around the repositories used for ultimate disposal of nuclear waste, the adsorption behavior of certain radionuclides onto and from these minerals and similar adsorbents should be studied in order to estimate the rates of transport of the nuclides in the event of water penetration into and through the repository. Information on the adsorption properties of the purified individual clay minerals may not be sufficient to predict the adsorption properties of a corresponding mixture, because these clay minerals may interact with each other and lead to modification of the adsorption properties of the mixture as compared to the pure minerals. The adsorption behavior of strontium on kaolinite and montmorillonite ...

2004-07-01

147

Accelerator mass spectrometry: state of the art  

Energy Technology Data Exchange (ETDEWEB)

Accelerator Mass Spectrometry (AMS) is the analytical technique of choice for the detection of long-lived radionuclides which cannot be practically analysed with decay counting or conventional mass spectrometry. The main use of AMS has been in the analysis of radiocarbon and other cosmogenic radionuclides for archaeological, geological and environmental applications. In addition, AMS has been recently applied in biomedicine to study exposure of human tissues to chemicals and biomolecules at attomole levels. There is also a world-wide effort to analyse rare nuclides of heavier masses, such as long-lived actinides, with important applications in safeguards and nuclear waste disposal. The use of AMS is limited by the expensive accelerator technology required and there are several attempts to develop smaller and cheaper AMS spectrometers. 5 refs.

1996-12-31

148

ZZ UKFY2, Fission Yields of Th, U, Np, Pu, Am, Cm, Cf Isotopes  

International Nuclear Information System (INIS)

Description of program or function: Format: ENDFB-6 format; Nuclides: Th-232, U-233, U-234, U-235, U-236, U-238, Np-237, Np-238, Pu-238, Pu-239, Pu-240, Pu-241, Pu-242, Am-241, Am-242, Am-243, Cm-243, Cm-244, Cm-245, and from the spontaneous fission of Cm-242, Cm-244, and Cf-252. Origin: New evaluation (Crouch 1, 2, 3, 4; UKFY1; JEF-1). A new evaluation of fission product yields from the thermal, fast, and 14 MeV neutron-induced fission of the following nuclides has been prepared in ENDFB-VI format: "2"3"2Th, "2"3"3U, "2"3"4U, "2"3"5U, "2"3"6U, "2"3"8U, "2"3"7Np, "2"3"8Np, "2"3"8Pu, "2"3"9Pu, "2"4"0Pu, "2"4"1Pu, "2"4"2Pu, "2"4"1Am, "2"4"2"mAm, "2"4"3Am, "2"4"3Cm, "2"4"4Cm, "2"4"5Cm; and from the spontaneous fission of "2"4"2Cm, "2"4"4Cm, and "2"5"2Cf

149

Status of the WAND (Waste Assay for Nonradioactive Disposal) project as of July 1997  

Energy Technology Data Exchange (ETDEWEB)

The WAND (Waste Assay for Nonradioactive Disposal) system can scan thought-to-be-clean, low-density waste (mostly paper and plastics) to determine whether the levels of any contaminant radioactivity are low enough to justify their disposal in normal public landfills or similar facilities. Such a screening would allow probably at least half of the large volume of low-density waste now buried at high cost in LANL`s Rad Waste Landfill (Area G at Technical Area 54) to be disposed of elsewhere at a much lower cost. The WAND System consists of a well-shielded bank of six 5-in.-diam. phoswich scintillation detectors; a mechanical conveyor system that carries a 12-in.-wide layer of either shredded material or packets of paper sheets beneath the bank of detectors; the electronics needed to process the outputs of the detectors; and a small computer to control the whole system and to perform the data analysis. WAND system minimum detectable activities (MDAs) for point sources range from ...

1998-03-01

150

Gamma-ray pulse height spectrum analysis on systems with multiple Ge detectors using a spectrum summing  

Energy Technology Data Exchange (ETDEWEB)

A technique has been developed at the Idaho National Engineering Laboratory to sum high resolution gamma-ray pulse spectra from systems with multiple Ge detectors. Lockheed Martin Idaho Technologies Company operates a multi-detector spectrometer configuration at the Stored Waste Examination Pilot Plant facility which is used to characterize the radio nuclide contents in waste drums destined for shipment to Waste Isolation Pilot Plant. This summing technique was developed to increase the sensitivity of the system, reduce the count times required to properly quantify the radionuclides and provide a more consistent methodology for combining data collected from multiple detectors. In spectrometer systems with multiple detectors looking at non homogenous waste forms it is often difficult to combine individual spectrum analysis results from each detector to obtain a meaningful result for the total waste container. This is particularly true when the counting statistics in ...

1997-05-01

151

APSTNG: Neutron interrogation for detection of nuclear and CW weapons, explosives, and drugs  

Energy Technology Data Exchange (ETDEWEB)

A recently developed neutron diagnostic probe system has the potential to satisfy a significant number of van-mobile and fixed- portal requirements for nondestructive verification of sealed munitions and detection of contraband explosives and drugs. The probe is based on a unique associated-particle sealed-tube neutron generator (APSTNG) that interrogates the object of interest with a low-intensity beam of 14-MeV neutrons generated from the deuterium-tritium reaction and that detects the alpha-particle associated with each neutron. Gamma-ray spectra of resulting neutron inelastic scattering and fission reactions identify nuclides associated with all major chemicals in chemical warfare agents, explosives, and drugs, as well as many pollutants and fissile and fertile special nuclear material. Flight times determined from determined from detection times of the gamma-rays and alpha-particles yield a separate tomographic image of each identified ...

1992-07-01

155

Volume reduction of reactor wastes by spray drying  

International Nuclear Information System (INIS)

Three simulated low-level reactor wastes were dried using a spray dryer-baghouse system. The three aqueous feedstocks were sodium sulfate waste characteristic of a BWR, boric acid waste characteristic of a PWR, and a waste mixture of ion exchange resins and filter aid. These slurries were spiked with nonradioactive iron, cobalt, and manganese (representing corrosion products) and nonradioactive cesium and iodine (representing fission products). The throughput for the 2.1-m-diameter spray dryer and baghouse system was 160-180 kg/h, which is comparable to the requirements for a full-scale commercial installation. A free-flowing, dry product was produced in all of the tests. The volume reduction factor ranged from 2.5 to 5.8; the baghouse decontamination factor was typically in the range of 10"3 to 10"4. Using an overall system decontamination factor of 10"6, the activity of the off-gas was calculated to be one to two orders of magnitude less than the nuclide release ...

156

Treatment of radioactive liquid waste by reverse osmosis; Influence of co-existing ions on the change of decontamination factor  

Energy Technology Data Exchange (ETDEWEB)

The report addresses the application of reverse osmosis to the treatment of radioactive liquid waste, focusing on the effects of non-radioactive cations and anions, existing in radioactive waste, on the removal of radioactive nuclides. The bivalent cations are generally about ten times as high in decontamination factor as monovalent ones. In the case of anions, the factor of SO{sub 4}{sup 2-} is about ten times that of Cl{sup -} while that of NO{sub 3}{sup -} is somewhat smaller than that of Cl{sup -}. During permeation through membrane, anions tend to accompany cations, and the decontamination factor of accompanying ions is found to increase with that of the paring ions. These results indicate that if one can select components that will remain in the liquid waste, one should consider their effects on the efficiency of its treatment. Furthermore, the interaction between two anions or between two cations can be approximated by a linear equation consisting of the ...

1991-01-01

157

Treatment of radioactive liquid waste by reverse osmosis  

International Nuclear Information System (INIS)

The report addresses the application of reverse osmosis to the treatment of radioactive liquid waste, focusing on the effects of non-radioactive cations and anions, existing in radioactive waste, on the removal of radioactive nuclides. The bivalent cations are generally about ten times as high in decontamination factor as monovalent ones. In the case of anions, the factor of SO_4"2"- is about ten times that of Cl"- while that of NO_3"- is somewhat smaller than that of Cl"-. During permeation through membrane, anions tend to accompany cations, and the decontamination factor of accompanying ions is found to increase with that of the paring ions. These results indicate that if one can select components that will remain in the liquid waste, one should consider their effects on the efficiency of its treatment. Furthermore, the interaction between two anions or between two cations can be approximated by a linear equation consisting of the logarithm of the decontamination ...

158

Toxicity of radioactive wastes generated from PEACER spent fuel  

Energy Technology Data Exchange (ETDEWEB)

Assessment on the back end fuel cycle, in PEACER (Proliferation-resistant Environmental-friendly Accident-tolerant Continuable and Economical Reactor) that was designated as a new transmutation concept, was performed. Recovery system of uranium and TRU for PEACER is based on pyroprocessing. In the assessment of Long-Lived Fission Products (LLFP) wastes, initially {sup 90}Sr and {sup 137}Cs are dominant contributor nuclides until 30 years and especially {sup 90}Sr and {sup 137}Cs have the highest activity and decay heat than other LLFP. In this study, recovery of {sup 90}Sr and {sup 137}Cs is recommended for reducing of wastes loading. The acceptable decontamination factor is investigated by the toxicity of PEACER spent fuel. The acceptable decontamination factor is about 1.02E+05 for the actinides from PEACER spent fuel after 10 years cooling, 4.26E+05 after 100 years cooling, 1.97E+04 after 300 years cooling, 9.52E+03 after 1000 years cooling.

2003-10-01

159

Toxicity of radioactive wastes generated from PEACER spent fuel  

International Nuclear Information System (INIS)

Assessment on the back end fuel cycle, in PEACER (Proliferation-resistant Environmental-friendly Accident-tolerant Continuable and Economical Reactor) that was designated as a new transmutation concept, was performed. Recovery system of uranium and TRU for PEACER is based on pyroprocessing. In the assessment of Long-Lived Fission Products (LLFP) wastes, initially "9"0Sr and "1"3"7Cs are dominant contributor nuclides until 30 years and especially "9"0Sr and "1"3"7Cs have the highest activity and decay heat than other LLFP. In this study, recovery of "9"0Sr and "1"3"7Cs is recommended for reducing of wastes loading. The acceptable decontamination factor is investigated by the toxicity of PEACER spent fuel. The acceptable decontamination factor is about 1.02E+05 for the actinides from PEACER spent fuel after 10 years cooling, 4.26E+05 after 100 years cooling, 1.97E+04 after 300 years cooling, 9.52E+03 after 1000 years cooling.

2003-10-01

160

Toxicity of Radioactive Wastes Generated from PEACER in Korea  

International Nuclear Information System (INIS)

Assessment on the back end fuel cycle, in PEACER (Proliferation-resistant Environmental-friendly Accident-tolerant Continuable and Economical Reactor) that was designated as a new transmutation concept, was performed. Recovery system of uranium and TRU for PEACER is based on pyro-processing. In the assessment of long-lived fission products (LLFP) wastes, initially "9"0Sr and "1"3"7Cs are dominant contributor nuclides until 30 years and especially "9"0Sr and "1"3"7Cs have the highest activity and decay heat than other LLFP. In this study, recovery of "9"0Sr and "1"3"7Cs is recommended for reducing of wastes loading. The acceptable decontamination factor is investigated by the toxicity of PEACER spent fuel. The acceptable decontamination factor is about 1.02 E+05 for the actinides from PEACER spent fuel after 10 years cooling, 4.26 E+05 after 100 years cooling, 1.97 E+04 after 300 years cooling, 9.52 E+03 after 1000 years cooling. (authors)

2006-06-04

161

The Role of Massive Agb Stars in the Early Solar System Composition  

CERN Document Server

We demonstrate that a massive asymptotic giant branch (AGB) star is a good candidate as the main source of short-lived radionuclides in the early solar system. Recent identification of massive (4-8 solar masses) AGB stars in the Galaxy, which are both lithium- and rubidium-rich, demonstrates that these stars experience proton captures at the base of the convective envelope (hot bottom burning), together with high-neutron density nucleosynthesis with 22Ne as a neutron source in the He shell and efficient dredge-up of the processed material. A model of a 6.5 solar masses star of solar metallicity can simultaneously match the abundances of 26Al, 41Ca, 60Fe, and 107Pd inferred to have been present in the solar nebula by using a dilution factor of 1 part of AGB material per 300 parts of original solar nebula material, and taking into account a time interval between injection of the short-lived nuclides and consolidation of the first meteorites equal to 0.53 Myr. Such a ...

2008-01-01

162

Strontium-90 and cesium-137 in service water from June to December, 1981  

International Nuclear Information System (INIS)

Service water, 100 l each, was collected at an intake of a water treatment plant and at a tap after water was left running for five minutes. The carriers of strontium and cesium were added to water immediately after sampling, and the sample was vigorously stirred and filtered. Then it was passed through a cation exchange column at a rate of 80 ml/min. Strontium and cesium were eluted with hydrochloric acid from the cation exchange column, and separated. After the radiochemical separation, the mounted precipitates were counted for activity using low background beta counters normally for 60 min. Net sample counting rates were corrected for counter efficiency, recovery, self absorption and decay to obtain the content of strontium-90 and cesium-137 radioactivity per sample aliquot. From the results, concentrations of these nuclides in the original sample were calculated. The maximum values obtained were 0.29 pCi/l of Sr-90 in Kyoto in August, 1981, and 0.02 pCi/l of ...

1981-12-01

163

Standardization of "2"4"1Am by digital coincidence counting, liquid scintillation counting and defined solid angle counting  

International Nuclear Information System (INIS)

The nuclide "2"4"1Am decays by alpha emission to "2"3"7Np. Most of the decays (84.6%) populate the excited level of "2"3"7Np with energy of 59.54 keV. Digital coincidence counting was applied to standardize a solution of "2"4"1Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid scintillation counting using the logical sum of double coincidences in a TDCR array and defined solid angle counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.

2009-09-07

164

Significance of the results from probabilistic safety assessment at level 2 for off-site consequences  

Energy Technology Data Exchange (ETDEWEB)

The procedure was developed to enable STUK (Radiation and Nuclear Safety Authority) to make simplified estimates on off-site consequences based on the existing results of the PSA level 2 calculations done by e.g. power utilities. Method is based on dose calculated from each nuclide group of reactor activity inventory when the same release fraction for each group is assumed. This means that a specific new result from PSA level 2 can be categorised to find out a representative PSA level 3 result for this case. In addition a user interface including the procedure was prepared. Secondly some new insights about consequences based on the releases from PSA level 2 is expected to give better understanding of risks at prevailing increased reactor power levels. In this case only some early health effects and long-term doses were estimated without full-scope PSA level 3 approach. (orig.)

2000-07-01

165

Nuclear Data Sheets for A = 166  

Energy Technology Data Exchange (ETDEWEB)

Nuclear structure data pertaining to all known A = 166 nuclides (Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu, Hf, Ta, W, Re, Os, Ir, Pt) have been compiled and evaluated, and incorporated into the ENSDF data file. This evaluation for A = 166 supersedes the previous publication (E.N. Shurshikov and N.V. Timofeeva, Nuclear Data Sheets 67, 45 (1992) (literature cutoff date 1 October 1990)) and the revision by C.M. Baglin of {sup 166}W (literature cutoff data 16 April 2000). It includes literature available by 1 March 2008. Subsequent to the previous evaluation, {sup 166}Gd has been observed for the first time and the first observations of excited states in {sup 166}Tb, {sup 166}Re, {sup 166}Os and {sup 166}Ir have been reported: also, knowledge of collective structure in {sup 166}Dy. {sup 166}Ho, {sup 1676}Er, {sup 166}Tm, {sup 166}Yb, {sup 166}Lu, {sup 166}Hf, and {sup 166}Ta has been considerably expanded. However, the structure suggested here for {sup 166}Re is highly tentative ...

2008-02-06

166

Isotopic composition of elements in extra-terrestrial materials 1  

Energy Technology Data Exchange (ETDEWEB)

The present review focuses on the isotropic composition in extra-terrestrial materials. There are many different factors in the variation in isotopic abundance between terrestrial and extra-terrestrial materials. Major factors in unusual isotopic composition are roughly grouped into three categories: factors associated with fractionation of isotopes, nuclear reaction or radioactive disintegration. Fractionation takes place due to differences in mass among various isotopes. There are physical and chemical factors. Physical ones include vaporization and condensation which meteorites may experience during their formation while the chemical ones include chemical reactions and chemical equilibration. There phenomena are mentioned as factors in the variation in isotopic ratio which is associated with nuclear reactions. An important nuclear reaction is the formation of elements that has been occurring continuously in stars since the big bang. The other two phenomena are nuclear spallation ...

1989-02-01

167

Efficient modeling for pulsed activation in inertial fusion energy reactors  

International Nuclear Information System (INIS)

First structural wall material (FSW) materials in inertial fusion energy (IFE) power reactors will be irradiated under typical repetition rates of 1-10 Hz, for an operation time as long as the total reactor lifetime. The main objective of the present work is to determine whether a continuous-pulsed (CP) approach can be an efficient method in modeling the pulsed activation process for operating conditions of FSW materials. The accuracy and practicability of this method was investigated both analytically and (for reaction/decay chains of two and three nuclides) by computational simulation. It was found that CP modeling is an accurate and practical method for calculating the neutron-activation of FSW materials. Its use is recommended instead of the equivalent steady-state method or the exact pulsed modeling. Moreover, the applicability of this method to components of an IFE power plant subject to repetition rates lower than those of the FSW is still being studied. The ...

2000-11-01

168

Characterization of spent fuel approved testing material: ATM-106  

Energy Technology Data Exchange (ETDEWEB)

The characterization data obtained to date are described for Approved Testing Material (ATM)-106 spent fuel from Assembly BT03 of pressurized-water reactor Calvert Cliffs No. 1. This report is one in a series being prepared by the Materials Characterization Center at Pacific Northwest Laboratory on spent fuel ATMs. The ATMs are receiving extensive examinations to provide a source of well- characterized spent fuel for testing in the US Department of Energy Office of Civilian Radioactive Waste Management (OCWRM) program. ATM-106 consists of 20 full-length irradiated fuel rods with rod-average burnups of about 3700 GJ/kgM (43 MWd/kgM) and expected fission gas release of /approximately/10%. Characterization data include (1) as-fabricated fuel design, irradiation history, and subsequent storage and handling; (2) isotopic gamma scans; (3) fission gas analyses; (4) ceramography of the fuel and metallography of the cladding; (5) calculated nuclide inventories and ...

1988-10-01

169

Characterization of spent fuel approved testing material: ATM-103  

Energy Technology Data Exchange (ETDEWEB)

The characterization data obtained to date are described for Approved Testing Material (ATM)-103, which is spent fuel from Assembly D101 of pressurized-water reactor Calvert Cliffs, No. 1. This report is one in a series being written by the Materials Characterization Center (MCC) at Pacific Northwest Laboratory (PNL) on spent fuel ATMs. The ATMs are receiving extensive examinations to provide a source of well-characterized spent fuel for testing in the US nuclear waste repository program. ATM-103 consists of 176 full-length irradiated fuel rods with rod-average burnups of about 2600 GJ/kgM (30 MWd/kgM) and less than 1% fission gas release. Characterization data include 1) as-fabricated fuel design, irradiation history, and subsequent storage and handling; 2) isotopic gamma scans; 3) fission gas analyses; 4) ceramography of the fuel and metallography of the cladding; 5) special fuels studies involving analytical transmission electron microscopy (AEM); 6) calculated ...

1988-04-01

170

Characterization of spent fuel approved testing material--ATM-104  

Energy Technology Data Exchange (ETDEWEB)

The characterization data obtained to date are described for Approved Testing Material 104 (ATM-104), which is spent fuel from Assembly DO47 of the Calvert Cliffs Nuclear Power Plant (Unit 1), a pressurized-water reactor. This report is one in a series being prepared by the Materials Characterization Center at Pacific Northwest Laboratory (PNL) on spent fuel ATMs. The ATMs are receiving extensive examinations to provide a source of well-characterized spent fuel for testing in the US Department of Energy Office of Civilian Radioactive Waste Management (OCRWM) Program. ATM-104 consists of 128 full-length irradiated fuel rods with rod-average burnups of about 42 MWd/kgM and expected fission gas release of about 1%. A variety of analyses were performed to investigate cladding characteristics, radionuclide inventory, and redistribution of fission products. Characterization data include (1) fabricated fuel design, irradiation history, and subsequent storage and handling history; (2) isotopic ...

1991-12-01

171

Characterization of spent fuel approved testing material---ATM-105  

Energy Technology Data Exchange (ETDEWEB)

The characterization data obtained to data are described for Approved Testing Material 105 (ATM-105), which is spent fuel from Bundles CZ346 and CZ348 of the Cooper Nuclear Power Plant, a boiling-water reactor. This report is one in a series being prepared by the Materials Characterization Center at Pacific Northwest Laboratory (PNL) on spent fuel ATMs. The ATMs are receiving extensive examinations to provide a source of well-characterized spent fuel for testing in the US Department of Energy Office of Civilian Radioactive Waste Management (OCRWM) Program. ATM-105 consists of 88 full-length irradiated fuel rods with rod-average burnups of about 2400 GJ/kgM (28 MWd/kgM) and expected fission gas release of about 1%. Characterization data include (1) descriptions of as-fabricated fuel design, irradiation history, and subsequent storage and handling; (2) isotopic gamma scans; (3) fission gas analyses; (4) ceramography of the fuel and metallography of the cladding; (5) special fuel studies ...

1991-12-01

172

Assessment of the nuclide concentration estimates with CASMO-4E with experimental data for very high burn-up UO_2 and MOX fuels  

International Nuclear Information System (INIS)

In this paper a computational analysis of 11 fuel samples (seven UO_2 and four MOX) with a burn-up ranging from 20 MWd/kgHM up to 121 MWd/kgHM (HM: Heavy Metal) is carried out with the depletion module of the lattice code CASMO-4E [Rhod01, Rhod01b] using the neutron data libraries ENDF/B-VI and JEF-2.2 and a pin cell model. In order to assess the accuracy of the model and the depletion calculation in the determination of the isotopic inventory after several irradiation cycles, the calculated results were compared to experimental data gathered from a chemical isotopic analysis of the fuel samples performed at the Hot Laboratory at the Paul Scherrer Institut (PSI), Switzerland. Selected results of this comparison, which includes 54 isotopes (17 actinides and 37 fission products), are presented here. (orig.)

173

Americium and curium total half-lives and for the spontaneous fission branch  

Energy Technology Data Exchange (ETDEWEB)

The long-lived nuclides of the americium and curium elements are of interest for their use in certain safeguard applications and for nuclear reactor burnup studies in waste management. Recommended values are presented for /sup 241,242m,243/Am, and for /sup 242,243,244,245,246,247,248,250/Cm. These values result from a consistent evaluation of all these half-lives. These preliminary estimates were presented earlier. The uncertainties are provided at the 95% confidence limit for each of the recommended values. It will be noted that many of the recommended errors considerably exceed errors quoted by individual authors in their publication, by up to an order of magnitude, e.g. the total half-life of /sup 242,246,248/Cm and the spontaneous fission half-life of /sup 244/Cm. These preliminary estimates for the half-lives were given previously. Efforts continue to reevaluate the various experiments to better gauge the systematic errors involved and reassess the total ...

1985-01-01

174

Actinides in liquid waste formed in the regeneration of nuclear fuel from a VVER-1000 reactor  

International Nuclear Information System (INIS)

In the radiochemical reprocessing of spent fuel from nuclear reactors, a considerable amount of liquid, solid, and gaseous waste is formed; this waste is potentially dangerous to humans and requires the development of special and complex technological techniques for its localization and reliable long-term storage. The most hazardous are liquid wastes of high specific activity - water-tailings solutions obtained in the first cycle of extraction after the removal of uranium and plutonium. These solutions contain more than 99.9% of all the other transuranic elements - isotopes of neptunium, americium, and curium. Where necessary, some fission products and actinides may be removed from wastes of high specific activity for subsequent use. The quantity, composition, and activity of these wastes varies within broad limits, depending on the type and power of the reactor, the initial nuclide composition of the fuel, and its specific energy yield, the regeneration ...

175

A gas-jet ECR ion source at TRIGA-SPEC  

International Nuclear Information System (INIS)

The TRIGA-SPEC experiment has been installed recently at the research reactor TRIGA Mainz. Ground state properties like masses, charge radii, spins, and moments of short-lived nuclides can be determined with very-high precision using the Penning trap mass spectrometer TRIGA-TRAP, and the collinear laser spectroscopy setup TRIGA-LASER. Short-lived neutron-rich radionuclides in the mass range 80 < A < 140 are produced by thermal neutron induced fission of e.g. U-235, Pu-239 or Cf-249, respectively. For the extraction and ionization of the fission products a gas-jet system is coupled to a 2.45-GHz ECR ion source for the production of singly charged ions. The gas-jet has been tested on-line and fission products have been extracted. First off-line tests of the ion source have been performed successfully with argon gas. The results of the commissioning test of the ion source and the on-line coupling of the experiments are presented.

2010-03-08

176

The Calculation and Measurement of Flexural and ...  

Science.gov (United States)

... Verheij (1980) described how the frequency domain could be exploited using cross spectral density measurements to measure the flexural ...

1996-02-01

177

TIMBER MEASUREMENTS (OTTER) - NASA  

Science.gov (United States)

Description: TIMBER MEASUREMENTS (OTTER). View entire list ... Dataset Title: TIMBER MEASUREMENTS (OTTER). Dataset Release Date: 1994 ...

180

Reference standard for carbonaceous impurity measurements in carbon nanotubes  

Science.gov (United States)

Near-infrared spectroscopy is a convenient tool for measuring nanotube / carbonaceous impurities

2004-01-01

181

Large scale magnetic field measurements and mapping  

CERN Document Server

Large scale magnetic field measurements and mapping

1984-01-01

183

Review of Subcritical Source-Driven Noise Analysis Measurements  

Energy Technology Data Exchange (ETDEWEB)

Subcritical source-driven noise measurements are simultaneous Rossia and randomly pulsed neutron measurements that provide measured quantities that can be related to the subcritical neutron multiplication factor. In fact, subcritical source-driven noise measurements should be performed in lieu of Rossia measurements because of the additional information that is obtained from noise measurements such as the spectral ratio and the coherence functions. The basic understanding of source-driven noise analysis measurements can be developed from a point reactor kinetics model to demonstrate how the measured quantities relate to the subcritical neutron multiplication factor.

1999-11-01

184

memorandum  

Wastenet

The nature of any pollution abatement measures that are required in operation.

187

Reproducibility of pulmonary mechanics measurements in dairy cattle.  

UK PubMed Central (United Kingdom)

The reproducibility of pulmonary mechanics measurements in dairy cattle was examined using two study designs. In design A measurements were made with six cows on two days, and in design B measurements...Full Text Available

1988-07-01

188

Measurements of Spectral Characteristics of Swimmer Targets ...  

Science.gov (United States)

... 3.0 Radar Measurements 3-1 3. 1 Spectral Density Measurements 3-2 3. 1. 1 System Calibration 3-3 ... 3. 1 SPECTRAL DENSITY MEASUREMENTS ...

1974-05-01

196
198

Transfer of uranium and thorium from soil to different parts of medicinal plants using SSNTD  

International Nuclear Information System (INIS)

The uptake of "2"3"8U and "2"3"2Th in different parts of some selected plants used in traditional treatment of hypertension and diabetes in south-eastern Morocco (Errachidia area) has been studied using two different types of solid state nuclear track detectors (SSNTDs) LR-115 type II and CR-39. Plant uptake of radionuclides is one of many vectors for introduction of contaminants into the human food chain. Thus, it is critical to understand soil-plant relationships that control nuclide bioavailability. Soil concentrations of uranium ranged from 6.10 to 11.62 ppm, with a mean of 7.90 ppm. Soil concentrations of thorium ranged from 2.70 to 4.80 ppm, with a mean of 3.41 ppm. Mean uranium specific activities were 8.38 Bq kg"-"1 in root tissue, 5 Bq kg"-"1 in stem tissue and 6.02 Bq kg"-"1 in leaf tissue. Mean thorium specific activities were 2.53 Bq kg"-"1 in root tissue, 1.64 Bq kg"-"1 in stem tissue and 1.96 Bq kg"-"1 in leaf tissue. The transfer factors of "2"3"8U ...

2011-02-01

199

New technetium-99m radiopharmaceuticals for brain imaging  

International Nuclear Information System (INIS)

Radiopharmaceuticals for brain imaging are used for the detection of ischemia, tumours and dementia associatied with disorders of the blood flow in the brain. The current radiopharmaceuticals for brain imaging have various limitations: 2-(F-18)fluoro-2-deoxyglucose (F-18-FDG) has a very short half-life. The physical properties of di-#beta#-(piperidinoethyl)-(Se-75)selenide (Se-75-PIPSE) and di-#beta#-(morpholinoethyl)-(Se-75)-selenide (Se-75-MOSE) are not ideal. Thallium-201 diethyldithricarbamate (T1-201-DDC) has unfavourable nuclidic characteristics, limited availability, a long half-life and high cost. I-123 in N-isopropyl-p-iodoamphetamine (I-123-IMP) and N,N,N'-trimethyl-N'-(2-hydroxy-3-methyl-5-iodobenzyl)-1,3-propanediamine (I-123-HIPDM) are not freely available and are expensive. N-13-labelled ammonia has a very short half-life. Technetium-99m hexamethylpropyleneamineoxime (Tc-99m-HM-PAO) is unstable both in vitro and in vivo and has a low brain-to-blood ...

1988-08-01

200

Five-particle, shell-model calculation using a spin-dependent potential as applied to $sup 101$Tc and the nuclear decays of $sup 101$Mo, $sup 101$Tc, $sup 142$Xe, and $sup 142$Cs  

Science.gov (United States)

Thesis. Five-particle shell-model calculations, using a spin-dependent potential, were performed for the nucleus /sup 101/Tc. The effects of varying the single-particle energy differences and the strengths of the spin-dependent and pairing terms are discussed. The isobars /sup 101/Mo and /sup 101/Tc were chemically separated to enable the detailed study of their decay schemes. As a result, 184 gamma rays were observed in the decay of /sup 101/Mo, and 169 of them were assigned to 45 levels in /sup 101/Tc. In the decay of /sup 101/Tc, 27 gamma rays were observed, and 26 of them were assigned to 11 levels in /sup 101/Ru. In a study of the decays of /sup 142/Xe and /sup 142/Cs the TRI STAN on-line isotope separator was used to separate the 142 mass chain produced in /sup 235/U fission with /sup 142/2Xe as the emanating and accelerated nuclide. Isobaric separation of /sup 142/Xe and /sup 142/Cs was achieved with a moving tape system. ...

1974-03-01

201

Exposure to radiation from the natural radioactivity in building materials  

International Nuclear Information System (INIS)

Radiation exposure of members of the public can be increased appreciably by the use of building materials containing above-normal levels of natural radioactivity. This phenomenon has attracted attention in recent years, and in this review, an attempt is made to the quantify exposures incurred under various circumstances. The second section of the review is a general survey of those building materials, mostly industrial wastes, that have aroused interest in Member countries. The probability that environmental pressures may cause such wastes to be used more and more by building industries may lead to similar situations in the future. Other review material of a relevant nature is described in the third section. Primordial radionuclides only are considered here. They are: potassium-40 (K-40); radium-226 (Ra-226) and its decay products; the series headed by thorium-232 (Th-232). The important radiological consequences of the natural radioactivity in building materials are two-fold, ...

2010-05-01

202

Development of Pyro-separation Technology Based on Molten Salt Electrolysis  

International Nuclear Information System (INIS)

The focus of this study was to develop recovery technologies in the pyroprocessing. The unit processes of the project can be classified into two groups; electro-refining process to recover uranium and long-lived nuclides, and cathode processing to produce a metal ingot both from a salt-contained metal and from Cd-contained metal. This project has been carried out for the third phase period of the long-term nuclear R and D program, and focused on the development of key technologies of the pyroprocessing such as electrorefining, draw down and cathode processing. Mock-up system of 1 kg-U/batch was built for performance tests which were conducted to ensure the adequacy of the research and development of the pyroprocessing technology. The experiments were carried out through bench-scale inactive tests except for uranium. In particular, the sticking problem was inevitable in the US's Mark-V and PEER electrorefiner. As a result of this study, a graphite cathode was ...

2001-07-18

203

Determination of trace amounts of cadmium, cobalt, chromium, iron, molybdenum, nickel, selenium, titanium, vanadium and zinc in blood and milk by neutron activation analysis  

International Nuclear Information System (INIS)

The concentrations of Cd, Co, Cr, Fe, Mo, Ni, Se, Ti, V and Zn in biological fluids, human blood serum and market milk were determined by neutron activation analysis, with enrichment by coprecipitation. The pre-concentration of these trace elements was accomplished by converting the dissolved trace metal ions into their pyrrolidinedithiocarbamate (1-pyrrolidinecarbodithioate) chelates, followed by coprecipitation with a metal carrier such as Ni, Pb or Bi. The coprecipitation was carried out prior to irradiation for the short-lived nuclides (V, Ti and Se) and after irradiation for the other elements. The validity of the method was checked using certified biological reference materials; the concentrations of trace elements found by the proposed method agreed well with the published certified data. The limits of detection for Cd, Co, Cr, Fe, Mo, Ni, Se (obtained through the long-lived isotope "7"5Se) and Zn under the present experimental conditions were found to be 5, ...

204

Derivation of guidelines for uranium residual radioactive material in soil at the B&T Metals Company site, Columbus, Ohio  

Energy Technology Data Exchange (ETDEWEB)

Guidelines for uranium residual radioactive material in soil were derived for the B&T Metals Company site in Columbus, Ohio. This site has been identified for remedial action under the US Department of Energy`s (DOE`s) Formerly Utilized Sites Remedial Action Program (FUSRAP). Single-nuclide and total-uranium guidelines were derived on the basis of the requirement that following remedial action, the 50-year committed effective dose equivalent to a hypothetical individual living or working in the immediate vicinity of the site should not exceed a dose constraint of 30 mrem/yr for the current use and likely future use scenarios or a dose limit of 100 n-mrem/yr for less likely future use scenarios. The DOE residual radioactive material guideline computer code, RESRAD, was used in this evaluation. RESRAD implements the methodology described in the DOE manual for establishing residual radioactive material guidelines. Three scenarios were considered; each assumed that ...

1996-01-01

205

Deep level transient spectroscopy characterization of defects introduced in n-GaAs after alpha irradiation at 15 K  

Energy Technology Data Exchange (ETDEWEB)

Using conventional deep level transient spectroscopy (DLTS), we have characterized the defects introduced in OMVPE n-GaAs at 15 K by 5.4 MeV alpha particle irradiation from an americium 241 radio-nuclide. After this low temperature irradiation two new defects not yet reported for alpha irradiated GaAs before, E[alpha]7 and E[alpha]9, were detected 0.07 eV and 0.19 eV below the conduction band, respectively. The introduction rates of E[alpha]7 and E[alpha]9 are calculated to be 41 cm[sup -1] and 187 cm[sup -1] respectively. It was observed that both defects obeyed first order annealing kinetics, with E[alpha]9 being removed at 225 K and E[alpha]7 at 245 K corresponding to the well known stage I annealing region. The annealing rate of E[alpha]7 corresponds to an activation energy of 0.86 eV, with a pre-exponential factor of 1.0 x 10[sup 15]s[sup -1]; and the removal of E[alpha]9 has an activation energy of 0.88 eV and a pre-exponential factor of 1.7 x 10[sup 17]s[sup ...

1993-08-01

206

Decontamination of cesium, strontium, and cobalt from aqueous solutions by bentonite  

Energy Technology Data Exchange (ETDEWEB)

Sorption studies of cesium, strontium, and cobalt (Cs, Sr, and Co) on bentonite under various experimental conditions, such as contact time, pH, sorbent and sorbate concentration, and temperature, have been performed. The sorption data for all these metals have been interpreted in terms of Freundlich, Langmuir, and Dubinin-Radushkevich equations. Thermodynamics parameters, such as heat of sorption {Delta}H{degrees}, free energy change {Delta}G{degrees}, and entropy change {Delta}S{degrees}, for the sorption of these metals on bentonite have been calculated. The value of {Delta}H{degrees} shows that the sorption of Cs was exothermic, while the sorption of Sr and Co on bentonite were endothermic in nature. The value of {Delta}G{degrees} for their sorption was negative, showing the spontaneity of the process. The maximum loading capacity of Cs, Sr, and Co were 75.5, 22, and 27.5 meq, respectively, for 100 g of bentonite. The mean free energy E of Cs, Sr, and Co sorption on bentonite was ...

1996-12-31

207

Decay of "1"0"1Mo and band structures of its daughter nuclide "1"0"1Tc in the projected shell model  

International Nuclear Information System (INIS)

The decay of molybdenum-101 has been investigated using the three-parameter (#gamma#-#gamma#-t) coincidence system of HPGe-HPGe detectors. According to the off-line analysis, the decay scheme was modified. The positions of 221.80, 318.00, 377.90; 452.50, 515.42, 1011.05, and 1759.72 keV transitions have been arranged again, the transition positions of 104.70, 105.95, and 774.15 keV gamma rays have been assigned for the first time, the positions of 169.00, 590.91, 980.52, and 1431.68 keV transitions have been reconfirmed, and the 1508.01 keV gamma ray was observed simultaneously for the first time and its transition position has been assigned. The #beta#"- intensities and the values of log ft of most levels were calculated. Combining with the high-spin states observed by the in-beam #gamma#-ray spectroscopy of previous decay works, the structure of the excited positive/negative-parity yrast states of "1"0"1Tc is discussed using a projected shell model, and a band diagram calculated for ...

2006-01-01

208

Calculated doses from inhaled transuranium radionuclides and potential risk equivalence to whole-body radiation  

International Nuclear Information System (INIS)

The distribution of radiation dose commitments within the body that can result from the lung deposition of a number of transuranic radionuclides ("2"3"7Pu, "2"3"8Pu, "2"3"9Pu, "2"4"0Pu, "2"4"1Pu, "2"4"2Pu, "2"4"3Pu, "2"4"4Pu, "2"4"1Am, "2"4"2Am, "2"4"3Am, "2"4"4Am, "2"4"2Cm, "2"4"3Cm, "2"4"4Cm, and "2"4"6Cm) was calculated. The variables that influence these organ dose commitments include the mobility of the particle or its dissolution products within the body, the radiation characteristics of the inhaled radionuclides and their progeny, and the size of the particles inhaled. In the calculation of organ dose commitments for whole-body, lungs, liver, bone tissues, kidneys, and gastrointestinal tract from the inhalation of transuranium radionuclides, physical characteristics of importance are the dimensions of the particle, its aerodynamic properties, and its density. For particles within the respirable size range, a useful description is provided by the activity median aerodynamic ...

1975-11-17

209

A comparison study on activation safety of fusion, fission and hybrid reactor technology  

Energy Technology Data Exchange (ETDEWEB)

The activation aspects of pure fusion and hybrid fusion technology is studied to assess the radioactive safety of various fusion concepts including tokamak pure fusion, fissile fuel producing hybrid and radio waste transmuting hybrid. The activation properties of breeding, coolant and structural materials in fusion reactors might be quite different from those in fission reactors because of the high energy D-T fusion neutrons from the fusion cores. A study on the involved activation reactions and the uncertainties of the associated nuclear cross-sections is carried. The activation properties of various first wall concepts and blanket concepts are discussed. The radioactive inventory during the operation lifetime and the potential hazard of the radioactive nuclides with respect to near term (reprocessing) and long term (waste disposal) aspects are calculated, with reference to ITER/NET (International Thermonuclear Experiment Reactor/Next European Torus), STARFIRE (a ...

1994-12-31

210

A comparison study on activation safety of fusion, fission and hybrid reactor technology  

International Nuclear Information System (INIS)

The activation aspects of pure fusion and hybrid fusion technology is studied to assess the radioactive safety of various fusion concepts including tokamak pure fusion, fissile fuel producing hybrid and radio waste transmuting hybrid. The activation properties of breeding, coolant and structural materials in fusion reactors might be quite different from those in fission reactors because of the high energy D-T fusion neutrons from the fusion cores. A study on the involved activation reactions and the uncertainties of the associated nuclear cross-sections is carried. The activation properties of various first wall concepts and blanket concepts are discussed. The radioactive inventory during the operation lifetime and the potential hazard of the radioactive nuclides with respect to near term (reprocessing) and long term (waste disposal) aspects are calculated, with reference to ITER/NET (International Thermonuclear Experiment Reactor/Next European Torus), STARFIRE (a ...

211

Vacuum Packaging for Microelectromechanical Systems ...  

Science.gov (United States)

... more than expected in developing a unique bond strength measurement protocol that is important for a wide range of bond strength measurements. ...

2002-10-01

212

THE APPLICATION OF STATISTICS TO THE FLIGHT ...  

Science.gov (United States)

... Measuring Instruments ..... 7-18 7.4 Power Spectral Density Measurements of Random DaL. .... 7-19 7 ...

1961-12-01

213

Surface Temperature - My NASA Data  

Science.gov (United States)

Surface temperature is measured with an infrared thermometer. Measuring Surface Temperature. Nine sample points are selected with a site of uniform land ...

214

Image Descriptors for Displays  

Science.gov (United States)

... 44 2. Luminance Power Spectral Density Measurements ..... 44 ... 50 4. Chrominance Power Spectral Density Measurements ..... 53 ...

1977-02-01

215

Evaluation of Daytime Boundary Layer Heights from a ...  

Science.gov (United States)

... the vertical beam measures the movement of the ... be measured because the particle velocity in ... During precipitation, if the hydrometeor fall velocity is ...

2008-03-01

216

Development and Calibration of Two and Four Wire Water ...  

Science.gov (United States)

... measurement. Power spectral density measurements are made by the dynamic signal analyzer for each channel. A cross power ...

1992-12-01

217

DEVELOPMENT OF A TUNED DAMPER TO REDUCE ...  

Science.gov (United States)

... Since power spectral density measurements are the result of a statisti- cal sampling process, as are the probability measurements, we now ...

1967-09-01

218

A HREELS Investigation of Ethylene on Pt Model Catalysts  

Science.gov (United States)

... analyzer section for angle resolved measurements, and a thin film evaporator with a quartz crystal microbalance to measure the mass deposition. ...

1990-05-20

219

Problems of the radiometric level measurement in large bins  

Energy Technology Data Exchange (ETDEWEB)

After a brief survey of the known level measurement methods the particularities of the radiometric measurement of the still utilisable residual volume of a bulk material in a large bin are discussed. At constant angle of repose the measurement in a suitably positioned plane of measurement suffices, at variable angle of repose two planes of measurement are required. The probable working ranges for a 1300-t lime bin are estimated.

1984-01-01

220

Metrology measurement capabilities  

Energy Technology Data Exchange (ETDEWEB)

Since 1958, the AlliedSignal Federal Manufacturing and Technologies (FM and T) Metrology Department has developed measurement technology and calibration capability in four major areas of measurement: mechanical; environmental, gas, liquid; electrical (D.C., A.C., RF/microwave); and optical and radiation. The capabilities developed include unique capabilities in many areas of measurement and engineering expertise to develop measurement techniques and resolve measurement problems in these major areas. FM and T Metrology was established in 1958 to provide a measurement base for the Department of energy`s Kansas City Plant. The Metrology Engineering Department provides the expertise to develop measurement capabilities for virtually any type of measurement which falls into the broad areas listed above. The engineering staff ...

1997-06-01

221

Calorimetric measurements of emittance of pipe surfaces: influence of enclosure diameter, test pipe length, and an argon atmosphere  

Energy Technology Data Exchange (ETDEWEB)

Additional results using a calorimetric technique for measuring the total hemispherical emittance of pipe surfaces from 400 to 600 K are described. Two different Pyrex pipe enclosures were used, one of 15 cm i.d. and the other of 30 cm i.d. An error analysis showed that the larger diameter Pyrex pipe should have a smaller error, but the difference was negligible for the 4.4-cm test pipe diameter used. Measurements on a short length of a previously-measured pipe agreed with earlier measurements, but only over the temperature range of the measurements. While the technique normally uses a vacuum to minimize nonradiative heat transfer, measurements were done succesfully with an argon atmosphere in a closed system. A nickel-plated pipe, measured first in a vacuum and then in an argon atmosphere, allowed calculation of an effective convective ...

1981-10-01

222

RESUME-95: Results of an International Field Test of Mobile Equipment for Emergency Response  

DEFF Research Database (Denmark)

In 1995 the exercise RESUME-95 (Rapid Environmental Surveying Using Mobile Equipment) took place in Finland. Groups from 8 European countries joined the exercise. The methods used were airborne gamma-ray measurements, car-borne measurements and in situ stationary measurements. The results of the measurements are analyses aiming at disclosing similarities and differences between groups and measuring techniques.

1997-01-01

223

Non-destructive measurement of corrosion effects on high temperature coatings  

Energy Technology Data Exchange (ETDEWEB)

Non-destructive methods for measuring the remaining anticorrosive or antioxidative ability of coatings are investigated. For anticorrosive chromium coatings the increasing ferromagnetism caused by loss of chromium is measured by a permeability probe. Measured values on blades after operation are correlated with the progress of corrosion as determined by metallographic methods. For antioxidative aluminum coatings the diminishing layer thickness is taken as indication for the exhaustion of their protection ability. The layer thickness is measured eddy current probes, especially developed for this application.

1990-01-01

224

Measurement of the oil consumption of compressors  

International Nuclear Information System (INIS)

This paper describes a method for measuring oil consumption in compressors. The oil is labelled with Zn 65. The consumed radioactive oil is retained in an activated carbon filter and its activity is measured continuously with a plastic scintillator detector. Measuring the oil consumption at a given operating levels takes about 15 minutes. At an oil consumption rate of about 1 g/h the measurement errors are of the order of +- 5%. (orig.).

225

Large cardinals with few measures  

CERN Document Server

We show, assuming the consistency of one measurable cardinal, that it is consistent for there to be exactly kappa+ many normal measures on the least measurable cardinal kappa. This answers a question of Stewart Baldwin. The methods generalize to higher cardinals, showing that the number of lambda strong compactness or lambda supercompactness measures on P_kappa(lambda) can be exactly lambda+, if lambda>kappa is a regular cardinal. We conclude with a list of open questions. Our proofs use a critical observation due to James Cummings.

2006-01-01

226

ZZ KAFAX-F22, 80 and 24 Groups Cross-Section Library in MATXS Format Based on JEF-2.2 for Fast Reactors  

International Nuclear Information System (INIS)

1 - Description: Format: MATXS. Number of groups: 80 neutron-, 24 photon-groups. 97 Nuclides: 1-H-1, 1-H-2, 2-He-3, 2-He-4, 3-Li-6, 3-Li-7, 4-Be-9, 5-B-10, 5-B-11, 6-C- nat., 7-N-14, 7-N-15, 8-O-16, 9-F-19, 11-Na-23, 12-Mg-nat., 13-Al-27, 14-Si-nat., 15-P-31, 17-Cl-nat., 18-Ar-40, 19-K-nat., 20-Ca-nat., 22-Ti-nat., 23-V-nat., 24-Cr-50, 24-Cr-52, 24-Cr-53, 24-Cr-54, 25-Mn-25, 26-Fe-54, 26-Fe-56, 26-Fe-57, 26-Fe-58, 27-Co-59, 28-Ni-58, 28-Ni-60, 28-Ni-61, 28-Ni-62, 28-Ni-64, 29-Cu-nat., 31-Ga-nat., 39-Y-89, 40-Zr-nat., 41-Nb-93, 42-Mo-nat., 47-Ag-107, 47-Ag-109, 48-Cd-nat., 50-Sn-nat., 63-Eu-151, 63-Eu-153, 64-Gd-152, 64-Gd-154, 64-Gd-155, 64-Gd-156, 64-Gd-157, 64-Gd-158, 64-Gd-160, 73-Ta-181, 74-W-182, 74-W-183, 74-W-184, 74-W-186, 75-Re-185, 75-Re-187, 79-Au-197, 82-Pb-nat., 83-Bi-209, 90-Th-232, 91-Pa-233, 92-U-232, 92-U-233, 92-U-234, 92-U-235, 92-U-236, 92-U-237, 92-U-238, 93-Np-237, 93-Np-238, 94-Pu-238, 94-Pu-239, 94-Pu-240, 94-Pu-241, 94-Pu-242, 95-Am-241, ...

227

Transport volume of other radioactive materials in the Federal Republic of Germany in the fields of application of research, medicine and technology; Befoerderungsaufkommen sonstiger radioaktiver Stoffe in der Bundesrepublik Deutschland im Anwendungsbereich Forschung, Medizin und Technik  

Energy Technology Data Exchange (ETDEWEB)

The transport-relevant basic data recorded within the framework of a federation-wide transport data survey made in 1986 are the best-founded source at present for determining the transport volume of other radioactive materials in different economic areas of the Federal Republic of Germany. Due to the high recording rates, a sufficiently complete survey can be provided in particular with regard to the transport volume (e.g.transports/consignments/cargos, transport distance) - with the exception of transport by ship - for the ranges of application in reserach, medicine and technology. However, as regards the radiologically relevant basic data and transport modalities, the information supplied by the transporting agencies is incomplete. A table gives a comprehensive survey of type and scope of the transport volume of other radioactive materials in the Federal Republic of Germany (excluding the GDR) for transport by road, rail and air. The table also includes data on the dose rate of ...

1994-08-01

228

Synthesis of polyester styrene resin beads as polymeric ionic exchangers by using chemical and irradiation techniques  

International Nuclear Information System (INIS)

The aim of the study is to prepare ionic exchangers using the polymerization of unsaturated polyster with monomeric styrene units in a ratio of 60%: 40% respectively. The type of method involved in this preparation, is called An Emulsion Polymerization. Such type of polymerization was carried out by two techniques: chemical and irradiation techniques. The first techniques requires the formation of free radical monomers by use of methyl Ethy Ketone Peroxide capable of decomposing into free radicals upon heating, while the other technique involves the use of gamma rays (using Co-60 source) capable of activating monomers towards free radical formations. A number of very effective chemical parameters and physical factors were used and investigated throughout the reactions such as: dispersant matrix, viscosity, rate of mixing, and irradiation dose. Besides, the study has included the study of the rate of Resin Beads Swelling which is thought to be another important part of investigation. ...

3087-01-01

229

Multivariate statistics in the identification of unknown nuclear material  

International Nuclear Information System (INIS)

The identification, and hence origin determination, of unknown nuclear material that might be found undeclared away from designated locations in the nuclear fuel cycle, is an important task in the frame of nuclear forensics. Material with forensic importance can be found at the microscopic level as particles in environmental samples indicating possible clandestine production of fissile material, and as bulky samples in the case of illicit trafficking of nuclear material. The objective of this work is to present, at a theoretical level, an isotopic finger-printing methodology which would determine the origin of unknown nuclear material with forensic importance. This is demonstrated for the case when the unknown nuclear material is spent nuclear fuel. The methodology is based on multivariate statistics, such as cluster and factor analysis, complemented by spent fuel isotopic composition simulations using the zero-dimensional depletion computer code ORIGEN2. A major source of error in the ...

2004-10-25

230

Groundwater flow analysis and dose rate estimates from releases to wells at a coastal site  

Energy Technology Data Exchange (ETDEWEB)

In the groundwater flow modelling part of this work the effective dilution volume in the well scenario was estimated by means of transient simulations of groundwater flow and transport, which are coupled due to the varying salinity. Both deep, drilled wells and shallow surface wells in the vicinity of the repository were considered. The simulations covered the time period from the present to 1000 years after the present. Conceptually the fractured bedrock consists of planar fracture zones (with a high fracture density and a greater ability to conduct water) and the intact rock (in which the fracture density and the hydraulic conductivity are low). For them the equivalent-continuum model was applied separately. Thus, the fractured bedrock was considered as piecewise homogeneous (except for the depth dependence) and isotropic continuum with representative average characteristics. A generic simulation model for groundwater flow and solute transport was developed on the basis of ...

2000-09-01

231

Transport into retina measured by short vascular perfusion in the rat.  

UK PubMed Central (United Kingdom)

1. The short duration cerebrovascular perfusion method for measuring permeability of the blood-brain barrier has been adapted to measuring transport into the retina. 2. The method has been characterized...Full Text Available

1993-10-01

232

Radon concentration measurement in dwellings in Belgrade  

International Nuclear Information System (INIS)

The results of the radon concentration measurements in dwellings in Belgrade were shown in this paper. The measurements were done using long term method with diffusion cups equipped with solid state nuclear track detector LR-115-II or CR-39. (author).

233

Novel Technique for Aerodynamic Force Measurement in Shock Tubes.  

Science.gov (United States)

For aerodynamic force measurement in the ISL shock tunnel, the authors have developed a novel measurement technique. Its key feature is a mounting support, which releases the test model and tightens it again after a free flight duration of 10 to 15 millis...

1989-01-01

234

Monte Carlo modeling of 60Co HDR brachytherapy source in water and in different solid water phantom materials  

UK PubMed Central (United Kingdom)

The reference medium for brachytherapy dose measurements is water. Accuracy of dose measurements of brachytherapy sources is critically dependent on precise measurement of the source–detector...Full Text Available

2010-01-01

235

Indoor radon concentration measurements by using SSNTD  

International Nuclear Information System (INIS)

In this paper, some results of the indoor radon concentration measurements are presented. Kodac track detectors LR 115, bare and in a cup were used for these measurements. Average winter/summer ratio was determined for the town of interest. (author). 5 refs, 1 fig., 1 tab.

236

Indoor radon concentration measurements  

International Nuclear Information System (INIS)

Some results of the indoor radon measurements are presented in this paper. Kodac track detectors LR-115 were used for these measurements. Average winter/spring ratio for indoor radon concentration was determined from the results obtained and is presented in this paper. (author).

237

Methodological Quality of Studies on the Measurement Properties of Neck Pain and Disability Questionnaires: A Systematic Review  

British Library Electronic Table of Contents (United Kingdom)

Objective: The aim of this study was to obtain an overview of the methodological quality of studies on the measurement properties of neck pain and disability questionnaires and to describe how well various aspects of the design and statistical analyses of studies on measurement properties are performed. Methods: A systematic review was performed of published studies on the measurement properties of neck pain and disability questionnaires. Two reviewers independently rated the quality of the studies using the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist. This checklist was developed in an international Delphi consensus study. Results: A total of 47 articles were included on the measurement properties of 8 different questionnaires. The meth...

2011-01-01

238

Fuzzy performance measurement of a supply chain in manufacturing companies  

British Library Electronic Table of Contents (United Kingdom)

This paper is aimed to present a fuzzy decision making approach to deal with the performance measurement in supply chain systems. In the manufacturing environment, performance measurement is based on different quantitative and qualitative factors. Some of these factors may have a larger effect on the performance measure than others. Units of measure of the quantitative factors are different such as time, money, percentage, ratio, and counts. Thus, this paper presents a performance measurement approach based on fuzzy set theory and the pair-wise comparison of Analytical Hierarchy Process (AHP), which ensures the consistency of the designer's assignments of importance of one factor over another to find the weight of each of the manufacturing activity in the departmental organization. In the ...

2011-01-01

239

A comparison of seasonal radon concentration and weekly screening measurements  

Energy Technology Data Exchange (ETDEWEB)

Short-term radon measurements were used to make a comparison between weekly screening tests and seasonal concentration. The screening measurements were made in an indoor environment over a period of one quarter during early summer and the results are compared with the measured average radon level over that period. In these experiments, the envelope-type and plastic bag monitors were used for screening and long term radon concentration measurements, respectively. The results show that one cannot achieve predicting the seasonal mean radon concentration based on weekly measurements better than 50% under the conditions reported. (author).

1993-12-31

240

A comparison of seasonal radon concentration and weekly screening measurements  

International Nuclear Information System (INIS)

Short-term radon measurements were used to make a comparison between weekly screening tests and seasonal concentration. The screening measurements were made in an indoor environment over a period of one quarter during early summer and the results are compared with the measured average radon level over that period. In these experiments, the envelope-type and plastic bag monitors were used for screening and long term radon concentration measurements, respectively. The results show that one cannot achieve predicting the seasonal mean radon concentration based on weekly measurements better than 50% under the conditions reported. (author).

241

View Datasets - ECHO - NASA  

Science.gov (United States)

This data set contains data from in situ infrared thermometer measurements ... Surface temperature was measured using an Apogee Infrared Thermometer from 23 ...

242

Synthesizer Stability Evaluation - NASA Technical Report Server (NTRS)  

Science.gov (United States)

verified via high-resolution spectral density measurements using the Hadamard Variance. .... spectral density measurements were made with the HF5390 ...

243

Safety measures for prevention of PCB accidents.  

UK PubMed Central (United Kingdom)

This paper attempts to clarify the most common measures available for the fire and electrical engineer in the prevention of polychlorinated biphenyl (PCB) hazards. It points out the risks and the potential...Full Text Available

1985-05-01

244

Prevalence-Dependent Costs of Parasite Virulence  

UK PubMed Central (United Kingdom)

Costs of parasitism are commonly measured by comparing the performance of infected groups of individuals to that of uninfected control groups. This measure potentially underestimates the cost of parasitism...Full Text Available

2005-08-01

245

Measurements of the concentration and composition of nuclei for cirrus formation  

UK PubMed Central (United Kingdom)

This article addresses the need for new data on indirect effects of natural and anthropogenic aerosol particles on atmospheric ice clouds. Simultaneous measurements of the concentration and composition...Full Text Available

2003-12-09

246

Measurement methods for human exposure analysis.  

UK PubMed Central (United Kingdom)

The general methods used to complete measurements of human exposures are identified and illustrations are provided for the cases of indirect and direct methods used for exposure analysis. The application...Full Text Available

1995-04-01

247

Maintaining Quality Performance in a Rapidly Changing Workplace - NASA  

Science.gov (United States)

360 degree Surveys. Measuring. Measuring successes successes ... Self- Assessment. Safeguards. Equipment. Reactor. Protection. Systems. Containment ...

248

Investigation of Behaviorally Modified Rats for Use in ...  

Science.gov (United States)

... F;qure Title phge 20 Rat B Spectral Density Measurements TNT Stimuli 70 21 Rat B Spectral Density Measurements Neutral Stimuli 71 ...

1981-12-01

249

Inclusive w and z cross section measurements at the Fermilab Tevatron  

Energy Technology Data Exchange (ETDEWEB)

The present recent measurements of the inclusive cross section of W and Z bosons from Run II of the Fermilab Tevatron collider.

2004-12-01

250

HPLC Phytoplankton Pigment Measurements ... - Ocean Color - NASA  

Science.gov (United States)

CHORS, SDSU. OCRT Meeting (Washington, D.C., 14-16 Apr 2004). HPLC Phytoplankton Pigment Measurements: Continuation of Climate Quality Data Records ...

251

Femtosecond Laser Passivation of GaAs Detector Material  

Science.gov (United States)

... The approach is to perform noise spectral density measurements and selected materials structure measurements on GaAs detector materials, with ...

2008-06-07

252

Entropy, similarity measure of interval-valued intuitionistic fuzzy sets and their applications  

British Library Electronic Table of Contents (United Kingdom)

In this paper we propose an entropy measure for interval-valued intuitionistic fuzzy sets, which generalizes three entropy measures defined independently by Szmidt, Wang and Huang, for intuitionistic fuzzy sets. We also give an approach to construct similarity measures using entropy measures for interval-valued intuitionistic fuzzy sets. In particular, the proposed entropy measure for interval-valued intuitionistic fuzzy sets can yield a similarity measure. Several illustrative examples are given to demonstrate the practicality and effectiveness of the proposed formulas. We apply the similarity measure to solve problems on pattern recognitions, multi-criteria fuzzy decision making and medical diagnosis.

2011-01-01

253

Electroweak measurements at CDF  

Energy Technology Data Exchange (ETDEWEB)

The authors present some recent measurements on electroweak physics using data collected by the CDF experiment at the Tevatron proton anti-proton collider ({radical}s = 1.96 TeV) at Fermilab.

2005-06-01

254

DSN Radio Science ... - InterPlanetary Network (IPN) Progress Report  

Science.gov (United States)

tions, final noise-power spectral density measurements were made. These measurements of the noise-power spectral density were not the desired phase- noise ...

255

Attachment Styles and Sleep Measures in a Community-Based Sample of Older Adults  

UK PubMed Central (United Kingdom)

BackgroundMeasures of attachment style are often used to appraise social and emotional health. In developmental literature, the concept of attachment is used to explain...Full Text Available

2009-06-01

256

An instrumented cylinder measuring pinch force and orientation  

UK PubMed Central (United Kingdom)

BackgroundThe function of a cylinder allowing simultaneous measurements of the opposition axis of the index finger and thumb of the hand and the magnitude of pinch force is described.Full Text Available

257

Algorithms for Internal Validation Clustering Measures in the Post Genomic Era  

CERN Document Server

Inferring cluster structure in microarray datasets is a fundamental task for the -omic sciences. A fundamental question in Statistics, Data Analysis and Classification, is the prediction of the number of clusters in a dataset, usually established via internal validation measures. Despite the wealth of internal measures available in the literature, new ones have been recently proposed, some of them specifically for microarray data. In this dissertation, a study of internal validation measures is given, paying particular attention to the stability based ones. Indeed, this class of measures is particularly prominent and promising in order to have a reliable estimate the number of clusters in a dataset. For those measures, a new general algorithmic paradigm is proposed here that highlights the richness of measures in this class and accounts for the ones already ...

2011-01-01

258

Advanced Distillation Curve Measurement with a Model Predictive Temperature Controller  

British Library Electronic Table of Contents (United Kingdom)

In previous work, several significant improvements in the measurement of distillation curves for complex fluids were introduced. The modifications to the classical measurement provide for (1) temperature and volume measurement(s) of low uncertainty, and most important, (2) a composition-explicit data channel in addition to the usual temperature?volume relationship. This latter modification is achieved with a new sampling approach that allows precise qualitative as well as quantitative analyses of each fraction, on the fly. In the new approach, the distillation temperature is measured in two locations. The temperature is measured in the usual location, at the bottom of the take-off in the distillation head, but it is also measured directly in the fluid. We have further modified our developm...

2006-01-01

259

A setup for high-resolution isotope shift measurements on unstable lithium isotopes  

Energy Technology Data Exchange (ETDEWEB)

We present a laser spectroscopic approach for measuring the charge radius of the halo nucleus {sup 11}Li and report on recent progress in the development of the experimental apparatus.

2003-05-01

260

A methodological review of resilience measurement scales  

UK PubMed Central (United Kingdom)

BackgroundThe evaluation of interventions and policies designed to promote resilience, and research to understand the determinants and associations, require reliable and valid measures...Full Text Available

261

A New Tool for Accurately Measuring the Inside Diameter of a ...  

Science.gov (United States)

Page 1. AD-769 272 A NEW TOOL FOR ACCURATELY MEASURING THE INSIDE DIAMETER OF A GUN BARREL, LONG TUBE, OR SIMILAR ...

1973-08-29

262

Aerodynamic force measurement on a large-scale model in a short duration test facility  

International Nuclear Information System (INIS)

A force measurement technique has been developed for large-scale aerodynamic models with a short test time. The technique is based on direct acceleration measurements, with miniature accelerometers mounted on a test model suspended by wires. Measuring acceleration at two different locations, the technique can eliminate oscillations from natural vibration of the model. The technique was used for drag force measurements on a 3 m long supersonic combustor model in the HIEST free-piston driven shock tunnel. A time resolution of 350 #mu#s is guaranteed during measurements, whose resolution is enough for ms order test time in HIEST. To evaluate measurement reliability and accuracy, measured values were compared with results from a three-dimensional Navier-Stokes numerical simulation. The difference between measured values and ...

2005-03-01

264

Wear measurements at railway wheel treads and brake discs with the radiometric thin-layer difference method  

International Nuclear Information System (INIS)

The investigation of important wear processes in the railway technique, especially the differentiation of the parameters influencing the wear process, requires extensive test programmes and thus high resolving methods to determine the wear. Radiometric methods enable considerably greater measuring accuracy with the help of the activation of materials than an observation of measurement or measuring changes. (orig./LH).

1975-04-03

270

Stress measurement and bolt tensioning by ultrasonic methods  

International Nuclear Information System (INIS)

In the past decade, a new technique has been developed for measuring tensile stresses in solids. This ultrasonic technique has been used thus far primarily for measuring fastener tension. The precision of measurement is routinely to 2-3% and, with special care, to approx. 1%. The method is insensitive to the frictional losses which plague tensioning by torque wrench. Though the approach is relatively new, it promises a wide range of applicability.

1980-01-01

271

Space Biology and Medicine  

Science.gov (United States)

Volume IV is devoted to examining the medical and associated organizational measures used to

2004-01-01

274

Rising Total Hadron-Hadron Cross Sections  

CERN Document Server

A historical summary is made on the measurements concerning the rising total hadron-hadron cross sections at high energies. The first part of this paper concerns the total cross section measurements performed at the Brookhaven, Serpukhov and Fermilab fixed target accelerators; then the measurements at the CERN Intersecting Storage Rings (ISR), and at the CERN and at the Tevatron Fermilab proton-antiproton colliders; finally the cosmic ray measurements at even higher energies. A short discussion on Conclusions and Perspectives follows.

2007-01-01

275

Radon transport in an activated charcoal canister  

Energy Technology Data Exchange (ETDEWEB)

The transport of Rn through activated charcoal was modelled for a charcoal canister used for surface emanation measurements. Derived Rn concentration distributions in full and half charcoal charges were compared with measured Rn profiles. The distributions were also compared with an empirical expression for the measured profiles. Close agreement was observed between the measured, empirically generated and derived profiles. The influence of temperature and humidity on Rn accumulation and transport is also discussed.

1989-02-01

276

Radon concentration measurements in caves Budapest  

International Nuclear Information System (INIS)

(1971). Hungary Viragh, E. Budapesti Muszaki Egyetem (Hungary).

279

Power density distribution by gamma scanning of fuel rods measurement technique in RA-8 critical facility  

International Nuclear Information System (INIS)

Power density measurements in the critical facility RA-8 are presented. These measurements were the first systematic use of the reactor. A measurement system was designed, built and proved for this goal. Power profiles are showed and the results are compared with calculated values. (author)

1999-10-26

285

Measuring equipment for the monitoring of air pollution control - a market review  

Energy Technology Data Exchange (ETDEWEB)

The paper abstracted gives a tabular survey of the suppliers and applications of measuring equipment. Equipment is available for the following fields of application: Continuous measuring instruments for stationary operation, laboratory equipment for sampling and hand equipment for mobile measurement, sampling equipment for examining emissions and gases, detectors, storage and evaluation equipment and meteorological instruments. (PW).

1986-01-01

286

Measures for Promoting Japan's Ocean Reseach and Investigation  

Science.gov (United States)

... Examples are when carbon dioxide and volcanic ash emitted into the atmosphere by volcanic eruptions ...

287

Measurement of time of travel in streams by dye tracing  

Energy Technology Data Exchange (ETDEWEB)

The US Geological survey is active in measuring time of travel in streams using dye tracers. This manual describes methods of measuring time of travel of water and waterborne solutes by dye tracing. The fluorescent dyes, measuring equipment used, and field and laboratory procedures are also described. Methods of analysis and presentation to illustrate time of travel of streams are provided.

1989-01-01

291

Magnetic forming studies  

Science.gov (United States)

Elastodynamic approach to measuring stress-strain relationship of uniaxially stressed wire, and

1967-01-01

294

Ignition Phenomena in Developmental, Stick Propellant ...  

Science.gov (United States)

... TEMPERATURE, PRESSURE MEASUREMENT, GUN CHAMBERS, COMPACTING, COMBUSTIBLE CARTRIDGE CASES, FLASH RADIOGRAPHY ...

1984-07-01

295

Hyperfine anomaly measurements in francium isotopes and the radial distribution of neutrons  

International Nuclear Information System (INIS)

We have performed precision measurements in a magneto-optical trap of the 7P1/2 hyperfine structure of the isotopes 209-210Fr. The ratio of these hyperfine constants to the previously measured 7S1/2 ground state values reveals a significant hyperfine anomaly. This anomaly results from the different radial dependence of the electron density in the two atomic levels. The measurements are sensitive to changes in the radial distribution of the neutron magnetism.

1999-09-01

297

Ground-temperature measurements  

Energy Technology Data Exchange (ETDEWEB)

Three papers are included. A separate abstract was prepared for each one. (MHR)

1981-01-01

301

Evaluation of Dry Chemicals by Photoacoustic Imaging  

Science.gov (United States)

In this study, an apparatus suitable to photoacoustic (PA) imaging to measure blood-analysis and urinalysis is fabricated and its measurement scheme has been established for the first time. The PA imaging of urinalysis test strip, blood sugar test strip, and cholesterol test strip is performed. A calibration curve of PA measurement is obtained for a urine test strip. The detectivity is better than that obtained by an eye-measurement.

1992-10-01

303

Direct measurements of secondary water inventory of steam generator PGV-213 in operation  

Energy Technology Data Exchange (ETDEWEB)

Results of weight measurement of PGV-213 steam generator during filling in, heating-up and power increase are described. Special measurement system based on stress gauges has been developed. Method of derivation of secondary water inventory is described. Comparison of the data for two steam generators prove accuracy of the measurements. (orig.). 1 refs.

1997-12-31

312

Absolute absorption of ozone in the midinfrared  

Energy Technology Data Exchange (ETDEWEB)

The absolute absorption of ozone in the midinfrared has been measured relative to 253.7-nm ultraviolet absorption to an accuracy of 1% using a Bruker Fourier transform spectrometer. These new results agree with previous measurements by diode laser measurements after the latter are corrected for more recent infrared calculations and ultraviolet cross sections. They also agree with a determination based on refractive index measurements in the infrared. 16 refs., 4 figs., 3 tabs.

1992-12-20

313

AUTOMATED TECHNOLOGY KNOWLEDGE BASE  

Science.gov (United States)

MAGNETIC FORMING .............. MAGNETIC INDUCTION ............ MAGNETIC MATERIALS ............ MAGNETIC MEASUREMENT .......... MAGNETIC PERMEABILITY . ...

314

A simple system of instruments for radionuclide X-ray fluorescence analysis in nonferrous metallurgy  

International Nuclear Information System (INIS)

Proceeding from commercially available instruments, a simple measuring system has been established, which renders possible fast and simple discontinuous analysis of individual elements. This measuring system is described, giving some examples of utilization in nonferrous metallurgy (mining, ore dressing, metallurgical treatment), and specific details, such as error of measurement, ranges of measurement and limits of utilization. (author).

1979-01-01

318

True and measured outgassing rates of a vacuum chamber with a reversibly adsorbed phase  

Energy Technology Data Exchange (ETDEWEB)

A pump down model for a vacuum chamber with a reversibly adsorbed phase is presented. The outgassing equation which predicts the variation of coverage at the wall surface of a vacuum chamber with time is derived. Then the measured and the true outgassing rates are defined. The theoretical measured outgassing rate shows only a very weak dependence for pumping speed. This prediction is opposite to the experimental result that the measured outgassing rate depends significantly on pumping speed. It is discussed that the experimental measured outgassing rate must be described as the product of the effective pumping speed and the measured pressure in the pumped chamber, in which the measured pressure is equivalent to the equilibrium pressure of the wall surface described by the equilibrium adsorption isotherm as a function of the shifted surface coverage ...

2000-03-01

319

The electron cyclotron absorption diagnostic for the JET pumped divertor plasma  

International Nuclear Information System (INIS)

We present the design of a diagnostic system to measure electron cyclotron absorption at the second harmonic E-mode resonance in the JET pumped divertor plasma. The diagnostic will measure transmission as a function of frequency along one or more sightlines from which the spatial profile of the n_eT_e product will be deduced. The divertor is briefly described, and the electron cyclotron resonance physics relevant to this measurement is reviewed. The problems of measuring transmission using an oversized transmission system are discussed and the chosen measurement technique, a swept frequency interferometer using a coherent radiation source, is described. A prototype of the instrument has been assembled to test the measurement technique. Some data demonstrating the instrument's characteristics are presented. The nonresonant losses, which may affect the ...

1993-03-01

320

Nuclear magnetic moment measurements through hyperfine interactions in highly stripped ions  

International Nuclear Information System (INIS)

Time-differential magnetic moment measurements on the first-excited Isup(#pi#)=2"+ states in "2"0Ne and "2"4Mg with mean lives of 1.0 and 2.1 ps, respectively are described. The lifetime of the latter state was determined simultaneously. A special detection geometry was designed to improve the experimental #gamma#-ray anisotropy measured with finite-size detectors. For "2"0Ne also a time-integral measurement with charge-state separation was performed. The necessary electronics circuitry built to perform these complicated measurements and the plunger assembly with laser interferometer are also described. A magnetic moment measurement of "2"2Ne(2_1"+) with tau=5.0 ps and transient field measurements at low and high recoil velocities are reported. A discussion of possible extensions of the techniques are given. (Auth.).

1975-09-15

321

Measurement of dose distributions of linear energy transfer in matter irradiated by fast neutrons  

Energy Technology Data Exchange (ETDEWEB)

A detector has been developed and used to measure dose distributions versus linear energy transfer to thin gas targets in spherical geometry from fast neutron irradiation of tissue-equivalent plastic and carbon. The detector is a hemispherical proportional counter with a Cs(T1) scintillator at the center of the hemisphere. The coincidence of the proportional counter signals constrain the measurements to charged particles traversing the radius of the hemisphere. The charged particle energy deposition distributions are directly measured for a known pathlength. The A-150 kerma factor was measured at a neutron energy of 14.8 MeV and is in agreement with tabulated values. The carbon kerma factor measurements are less than the tabulated value at 14.8 MeV. The alpha-particle production in carbon was measured for neutron energies from 14.1 to 14.8 MeV and is compared ...

1990-01-01

322

Redox potential measurement in the power station  

Energy Technology Data Exchange (ETDEWEB)

By its very nature redox potential measurement is suitable for determining the concentration ratio of a stable redox pair through its interaction with a chemically inert electrode surface but not the absolute concentration of a material. The measured redox potentials agree only rarely with those which are easily calculable theoretically. No individual defined stable redox pair is available in power station water. It is therefore not simply possible to measure definable mixed potentials more precisely. For these reasons redox potential measurement in the power station, as also with other types of water, can no longer be regarded as an indicator, by which it can be established whether oxidizing or reducing materials predominate in the water.

1983-01-01

323

Redox potential measurement in the power station  

International Nuclear Information System (INIS)

By its very nature redox potential measurement is suitable for determining the concentration ratio of a stable redox pair through its interaction with a chemically inert electrode surface but not the absolute concentration of a material. The measured redox potentials agree only rarely with those which are easily calculable theoretically. No individual defined stable redox pair is available in power station water. It is therefore not simply possible to measure definable mixed potentials more precisely. For these reasons redox potential measurement in the power station, as also with other types of water, can no longer be regarded as an indicator, by which it can be established whether oxidizing or reducing materials predominate in the water. (orig.).

324

Overview of bunch length measurements.  

Energy Technology Data Exchange (ETDEWEB)

An overview of particle and photon beam bunch length measurements is presented in the context of free-electron laser (FEL) challenges. Particle-beam peak current is a critical factor in obtaining adequate FEL gain for both oscillators and self-amplified spontaneous emission (SASE) devices. Since measurement of charge is a standard measurement, the bunch length becomes the key issue for ultrashort bunches. Both time-domain and frequency-domain techniques are presented in the context of using electromagnetic radiation over eight orders of magnitude in wavelength. In addition, the measurement of microbunching in a micropulse is addressed.

1999-02-19

325

On measuring vulnerability to poverty  

British Library Electronic Table of Contents (United Kingdom)

There is a growing interest on dynamic and broader concepts of deprivation such as vulnerability, which takes in to account the destitution of individuals from future shocks. We use the framework of decision making under uncertainty to arrive at a new measure of vulnerability to poverty. We highlight the importance of current standard of living to better capture the notion of vulnerability. In conceptualizing the new class of measures of vulnerability, we thus move beyond the standard expected poverty measures that is commonly found in the literature. We also axiomatically characterize the new class of measure and discuss some of its properties.

2011-01-01

326

Initial RF measurements of the CW normal-conducting RF injector  

Energy Technology Data Exchange (ETDEWEB)

The LANL 2.5-cell, normal-conducting radio-frequency (NCRF) injector has been fabricated. We present initial results of low-power RF measurements (cavity Q, cavity field map, coupling beta, etc.) of the NCRF injector. The measured cavity Q and relative fields are found to be in good agreement with the design calculations and earlier measurements of Glidcop properties. However, the coupling beta of the ridge-loaded waveguides is found to be significantly higher than the design point. The impact of these low-power measurement results on the planned high-power RF and electron beam tests will be discussed.

2008-01-01

327

Influence of changes in the composition of Kh18N10T steel on the results of measurement of its thickness by the radiometric method  

International Nuclear Information System (INIS)

The additional error in measurement of the thickness of Kh18N10T steel for possible changes in composition with an energy of the photons of ionizing radiation of 10-80 keV was evaluated. The desirability of use of a type REIS-I x-ray emitter in measurement of the thickness of steel up to 1 mm is shown. The instrument provides measurement of the thickness of steel in the 0.1-1.0 mm range with a reproducibility of the results with an error not exceeding 0.5-1.0%. The measurement error with corrugations characteristic of bellows does not exceed 5%.

328

Application of /sup 252/Cf-source driven noise analysis measurements for subcriticality of HFIR fuel elements  

Energy Technology Data Exchange (ETDEWEB)

The approach-to-critical measurements reported were for a plate-type fuel element where the height of the water moderator and side and top reflector were increased. Measurements were also performed with each of the two annuli of the fuel element to verify both the presence of boron in the fuel plates and the proper uranium loading prior to assembly of the two annuli for full submersion measurements. Measurements were also performed with detectors external to the reflector (> 15 cm of water on top, bottom, and side) for the assembled, submerged HFIR fuel element.

1983-01-01

329

AC loss measurements of model and full size 50mm SSC collider dipole magnets at Fermilab  

Energy Technology Data Exchange (ETDEWEB)

Tests have recently been performed at Fermilab in order to measure the energy losses due to eddy currents and iron and superconductor magnetization. These measurements were performed on six 1.5m long model magnets and eight 15m long full scale collider dipole magnets. AC losses were measured as a function of ramp rate using sawtooth ramps from 500, to 5000 Amps for both types of magnets, while bipolar studies were additionally performed on some of the short magnets. The measured magnet voltage and current for a complete cycle are digitally integrated to yield the energy loss per cycle. Measurement reproducibility is typically 5%, with good agreement between long magnet measurements and extrapolations from short magnet measurement results. Magnetization loss measurements among similar magnet types agree to within ...

1992-09-01

330

ZZ MCJEF22NEA.BOLIB, MCNP Cross Section Library Based on JEF-2.2  

International Nuclear Information System (INIS)

1 - Description or function: Continuous energy cross-section data library for the Monte Carlo program MCNP based on the JEF-2.2 evaluated nuclear data library (ACE Format). Format: ACE Number of groups: Continuous energy Nuclides (107): H-1, H-2, He-4, Li-6, Li-7, Be-9, B-10, B-11, C-nat, N-14, N-15, O-16, O-17, F-19, Na-23, Mg-nat, Al-27, Si-nat, Cl-nat, Ti-nat, Cr-50, Cr-52, Cr-53, Cr-54, Mn-55, Fe-54, Fe-56, Fe-57, Fe-58, Co-59, Ni-58, Ni-60, Ni-61, Ni-62, Ni-64, Zr-90, Zr-91, Zr-92, Zr-94, Zr-96, Zr-nat, Nb-93, Mo-92, Mo-94, Mo-95, Mo-96, Mo-97, Mo-98, Mo-100, Mo-nat, Tc-99, Ru-101, Ru-102, Ru-104, Rh-103, Pd-105, Pd-107, Ag-109, I-129, Xe-131, Cs-133, Pr-141, Nd-143, Nd-145, Pm-147, Sm-147, Sm-149, Sm-150, Sm-151, Sm-152, Eu-153, Gd-154, Gd-155, Gd-156, Gd-157, Gd-158, Gd-160, Hf-174, Hf-176, Hf-177, Hf-178, Hf-179, Hf-180, Pb-nat, Bi-209, Th-232, U-234, U-235, U-236, U-238, Np-237, Pu-238, Pu-239, Pu-239bis, Pu-240, Pu-241, Pu-242, Am-241, Am-242, Am-242m, ...

331

ZZ MCB63NEA.BOLIB, MCNP Cross Section Library Based on ENDF/B-VI Release 3  

International Nuclear Information System (INIS)

1 - Description of program or function: Continuous energy cross-section data library for the Monte Carlo program MCNP based on the ENDF/B-VI Release 3 evaluated nuclear data library (ACE Format). Format: ACE; Number of groups: Continuous energy; Nuclides (107): H-1, H-2, He-4, Li-6, Li-7, Be-9, B-10, B-11, C-nat, N-14, N-15, O-16, O-17, Na-23, Mg-nat, Al-27, Si-nat, Cl-nat, Ti-nat, Cr-50, Cr-52, Cr-53, Cr-54, Mn-55, Fe-54, Fe-56, Fe-57, Fe-58, Co-59, Ni-58, Ni-60, Ni-61, Ni-62, Ni-64, Zr-90, Zr-91, Zr-92, Zr-94, Zr-96, Zr-nat, Nb-93, Mo-94, Mo-95, Mo-96, Mo-97, Mo-nat, Tc-99, Ru-101, Ru-102, Ru-104, Rh-103, Pd-105, Pd-107, Ag-109, I-129, Xe-131, Cs-133, Pr-141, Nd-143, Nd-145, Pm-147, Sm-147, Sm-149, Sm-150, Sm-151, Sm-152, Eu-153, Gd-154, Gd-155, Gd-156, Gd-157, Gd-158, Gd-160, Hf-174, Hf-176, Hf-177, Hf-178, Hf-179, Hf-180, Hf-nat, Pb-206, Pb-207, Pb-208, Bi-209, Th-232,U-233, U-234, U-235, U-236, U-238, Np-237, Pu-238, Pu-239, Pu-240, Pu-241, Pu-242, Am-241, ...

332

Total hemispherical emittance measured at high temperatures by the calorimetric method  

Energy Technology Data Exchange (ETDEWEB)

A calorimetric vacuum emissometer (CVE) capable of measuring total hemispherical emittance of surfaces at elevated temperatures was designed, built, and tested. Several materials with a wide range of emittances were measured in the CVE between 773 to 923 K. These results were compared to values calculated from spectral emittance curves measured in a room temperature Hohlraum reflectometer and in an open-air elevated temperature emissometer. The results differed by as much as 0.2 for some materials but were in closer agreement for the more highly-emitting, diffuse-reflecting samples. The differences were attributed to temperature, atmospheric, and directional effects, and errors in the Hohlraum and emissometer measurements ({+-} 5 percent). The probable error of the CVE measurements was typically less than 1 percent.

1994-09-01

333

Evaluation of Reports on Environmental Measurements of Electromagnetic Fields Generated by High Voltage Transmission Lines and Substations  

International Nuclear Information System (INIS)

This paper presents some situations, in which measurements of electromagnetic fields generated by transmission lines and substations should be performed. The range of measurements may differ, but maximum values of electric and magnetic fields and flux density must be identified in all situations. The area with electric field exceeding 1 kV/m should be identified as well. The author also presents basic requirements to be met by the measurement technique. These requirements are specified according to the national standard. Special attention should be paid to the identification of the spatial distribution of electric field and flux density generated in the vicinity of high voltage transmission lines. To verify the measurement results, it is necessary to calculate the distribution of both aforesaid field components. For environmental protection purposes, it is also proposed that the report should include ...

2007-01-01

334

Demonstration experiments of volume measurement technique for large scale input accountancy tank  

International Nuclear Information System (INIS)

Tank calibration experiments have been carried out using a mock-up input accountancy tank with the object of developing a high accuracy solution volume measurement technique for Rokkasho Reprocessing Plant (RRP). The experimental parameters such as temperature, solution density, off gas pressure and so on have been fluctuated in the calibration experiments in order to evaluate the influence on the solution volume measurement. As a result, it was confirmed that the solution volume measurement error of the mock-up tank was within #+-#0.04% (at full volume) using careful data correction technique for measured data. For the high accuracy volume measurement at RRP, it is important to correct data properly taking account of the actual conditions such as uncontrollable ambient temperature that are different from the experiment. (author)

2000-12-07

335

Calibration of Initial Measurements from the Full Aperture Backscatter system on NIF  

Energy Technology Data Exchange (ETDEWEB)

The Full Aperture Backscatter System (FABS) provides a measure of the spectral power, and integrated energy scattered by stimulated Brillouin (348-354 nm) and Raman (400 - 700 nm) scattering into the final focusing lens of the first four beams of the NIF laser. The system was designed to provide measurements at the highest expected fluences with: (1) spectral and temporal resolution, (2) beam aperture averaging, and (3) near-field imaging. This is accomplished with a strongly attenuating diffusive fiber coupler and streaked spectrometer and separate calibrated time integrated spectrometers, and imaging cameras. Measurement of the wavelength dependent sensitivity of the complete system is accomplished with a calibrated Xe lamp. Data from the calibration system is combined with experimental data to produce the power and energy measurements. Examples of measurements will be discussed.

2004-04-01

336

Apparatus for total hemispherical emittance measurements of full-scale receiver pipes from 100 to 300 C  

Energy Technology Data Exchange (ETDEWEB)

An apparatus is described for measuring the total hemispherical emittance of pipes of a length suitable for use in a prototype solar collector. The calorimetric method used requires measurements of the temperatures of the surface of the test pipe and of a concentric outer cylinder and measurement of the electrical power used to heat the test pipe. Measurements were made of the total hemispherical emittance of black chrome, nickel, and bare steel pipes as a function of temperature. The emittance of the black chrome surfaces increased significantly from an extrapolated value of about 0.1 at 25 deg C to values on the order of 0.3-0.4 at 300 deg C. The extrapolated values for black chrome agreed with measurements made using other techniques at room temperature. The results for the nickel-plated pipe agreed with total emittance calculated from spectral reflectance data.

1981-01-01

337

Air pollution in Berlin and its surroundings in 1989. Luftverschmutzung in Berlin und Umgebung im Jahr 1989  

Energy Technology Data Exchange (ETDEWEB)

The report presents details of the distributions of air pollution in the Berlin area and the developments of the past 20 years. Highly polluted areas are indicated in which air pollution reduction measures are particularly urgent. The report therefore intends not only to inform but also to point out the deficiencies of air pollution abatement measures, so that political consequences can be derived and measures can be taken. In all, data were recorded by 39 measuring stations in West Berlin, 16 in East Berlin, and 7 in Potsdam and Frankfurt/Oder. In most stations, sulphur dioxide and airborne dust were measured; 14 stations in West Berlin and one in East Berlin measured carbon monoxide and nitric oxides; 8 stations in West Berlin recorded ozone concentrations. (orig./KW).

1990-10-01

338

Polyp measurement based on CT colonography and colonoscopy: variability and systematic differences  

Energy Technology Data Exchange (ETDEWEB)

To assess the variability and systematic differences in polyp measurements on optical colonoscopy and CT colonography. Gastroenterologists measured 51 polyps by visual estimation, forceps comparison and linear probe. CT colonography observers randomly assessed polyp size two-dimensionally (abdominal and intermediate window) and three-dimensionally (manually and semi-automatically). Linear mixed models were used to assess the variability and systematic differences between CT colonography and optical colonoscopy techniques. The variability of forceps and linear probe measurements was comparable and both showed less variability than measurement by visual assessment. Measurements by linear probe were 0.7 mm smaller than measurements by visual assessment or by forceps. The variability of all CT colonography techniques was lower than for ...

2010-06-15

339

Using knowledge brokers to facilitate the uptake of pediatric measurement tools into clinical practice: a before-after intervention study  

UK PubMed Central (United Kingdom)

BackgroundThe use of measurement tools is an essential part of good evidence-based practice; however, physiotherapists (PTs) are not always confident when selecting, administering,...Full Text Available

340

Using and Interpreting Adjusted NNT Measures in Biomedical Research  

UK PubMed Central (United Kingdom)

The number needed to treat (NNT) is a popular effect measure to present study results in biomedical research. NNTs were originally proposed to describe the absolute effect of a new treatment compared...Full Text Available

341

Use of solid state nuclear track detectors for radon concentration measurements indoors  

International Nuclear Information System (INIS)

An indoor radioactive survey is being conducted in an Italian district. Preliminary results identified a zone with significant radioactive levels, in which a new specific survey has been planned. In this paper attention is dedicated mainly to radon measurement technique and results.

342

Ultrasonic Acoustic Emissions from the Sapwood of Cedar and Hemlock 1  

UK PubMed Central (United Kingdom)

Measurements are reported of ultrasonic acoustic emissions (AEs) measured from sapwood samples of Thuja occidentalis L. and Tsuga canadensis (L.) Carr. during air dehydration....Full Text Available

1984-08-01

343

Threshold Average Precision (TAP-k): a measure of retrieval designed for bioinformatics  

UK PubMed Central (United Kingdom)

Motivation: Since database retrieval is a fundamental operation, the measurement of retrieval efficacy is critical to progress in bioinformatics. This article points out some issues with...Full Text Available

2010-07-15

344

The use of nitrogen isotopes in research on sheep nutrition  

International Nuclear Information System (INIS)

Using nitrogen-13 initial measurements have been made of rumen ammonia-nitrogen pool size and turnover, and rate of incorporation of ammonia into microbial protein. It is also feasible to measure the rate of incorporation of absorbed ammonia into urea and the appearance of label in saliva.

1985-08-26

345

The measurement of polarization in backward scattering for the reactions $\\pi^{+} p \\rightarrow p \\pi^{+},K^{+} p \\rightarrow p K^{+}$ and $\\;\\pi^{+} p \\rightarrow \\Sigma^{+} K^{+}$  

CERN Multimedia

The measurement of polarization in backward scattering for the reactions $\\pi^{+} p \\rightarrow p \\pi^{+},K^{+} p \\rightarrow p K^{+}$ and $\\;\\pi^{+} p \\rightarrow \\Sigma^{+} K^{+}$

2006-01-01

346

Semileptonic b to u transition  

CERN Document Server

Experimental studies of charmless semileptonic B decays can be broadly categorized into inclusive and exclusive measurements depending on how the final states are treated. The inclusive method measures the decay rate $\\Gamma(B \\to X_u \\ell \

2007-01-01

347

Redistribution of pulmonary blood flow impacts thermodilution-based extravascular lung water measurements in a model of acute lung injury  

UK PubMed Central (United Kingdom)

BackgroundStudies using transthoracic thermodilution have demonstrated increased extravascular lung water (EVLW) measurements attributed to progression of edema and...Full Text Available

2009-11-01

348

Real-time neutron radiography system performance - Measurements and methods  

Energy Technology Data Exchange (ETDEWEB)

The University of Virginia's real-time neutron radiography facility was characterized by measurement of the total neutron flux, gold/cadmium ratio, neutron/gamma ratio, and the effective collimar length-to-aperture diameter (L/D) ratio. The real-time neutron imaging system and collimator were further characterized by measuring the modulation transfer function (MTF) of the system. The collimator effectiveness was measured by using the MTF to determine the ''unparallelism'' of the neutron beam. The computer-based image processing system allowed rapid calculation of the MTF and the collimator effectiveness. The results of these measurements, using no collimator and a simple tube collimator, demonstrated the method's ability to determine the effective L/D ratio. The MTF measurement scheme provided a fast, reliable, and reproducible ...

1988-09-01

349

Real-time neutron radiography system performance - Measurements and methods  

International Nuclear Information System (INIS)

The University of Virginia's real-time neutron radiography facility was characterized by measurement of the total neutron flux, gold/cadmium ratio, neutron/gamma ratio, and the effective collimar length-to-aperture diameter (L/D) ratio. The real-time neutron imaging system and collimator were further characterized by measuring the modulation transfer function (MTF) of the system. The collimator effectiveness was measured by using the MTF to determine the ''unparallelism'' of the neutron beam. The computer-based image processing system allowed rapid calculation of the MTF and the collimator effectiveness. The results of these measurements, using no collimator and a simple tube collimator, demonstrated the method's ability to determine the effective L/D ratio. The MTF measurement scheme provided a fast, reliable, and reproducible means of monitoring any changes in the real-time ...

1988-01-01

350

Rate of allosteric change in hemoglobin measured by modulated excitation using fluorescence detection.  

UK PubMed Central (United Kingdom)

We have measured the forward and reverse rates of the allosteric transition of hemoglobin A with three CO molecules bound by using modulated excitation coupled with fluorescence quenching of the DPG...Full Text Available

1989-10-01

351

RESPONSE LATENCY AS AN INDEX OF RESPONSE STRENGTH DURING FUNCTIONAL ANALYSES OF PROBLEM BEHAVIOR  

UK PubMed Central (United Kingdom)

Dependent variables in research on problem behavior typically are based on measures of response repetition, but these measures may be problematic when behavior poses high risk or when its occurrence...Full Text Available

2011-01-01

352

Quality measurement and control in physician decision making: state of the art.  

UK PubMed Central (United Kingdom)

The status of the concept of controlling the quality of physicians is reviewed as are studies that have been done on methods to measure and improve quality. The conclusions are dismal given the rhetoric...Full Text Available

1982-01-01

353

Principle of pulse frequency measurement and methods for improving frequency meters accuracy  

Energy Technology Data Exchange (ETDEWEB)

Specificity of the pulses mean frequency measurement (the pulses being generated in a stochastic process) is described. Status of the domain of analog frequency meters is presented. Methods of increasing accuracy of such meters are discussed.

1980-01-01

354

Principle of pulse frequency measurement and methods for improving frequency meters accuracy  

International Nuclear Information System (INIS)

Specificity of the pulses mean frequency measurement (the pulses being generated in a stochastic process) is described. Status of the domain of analog frequency meters is presented. Methods of increasing accuracy of such meters are discussed. (author).

1980-01-01

355

Pressure Probe Technique for Measuring Water Relations of Cells in Higher Plants 1  

UK PubMed Central (United Kingdom)

A new method is described for continuously measuring cell turgor pressure (P), hydraulic conductivity (Lp), and volumetric elastic modulus (ε) in higher plant cells, using a pressure...Full Text Available

1978-02-01

356

Porosity Measurement of Combustible Cartridge Case Materials.  

Science.gov (United States)

Research to develop an accurate and reproducible density test for 60-mm and 81-mm mortar propellant increment containers (combustible cartridge cases) was not successful. However, application of modern industrial porosity measurement techniques may afford...

1981-01-01

357

Pattern formation and traveling waves in myxobacteria: Theory and modeling  

UK PubMed Central (United Kingdom)

Recent experiments have provided new quantitative measurements of the rippling phenomenon in fields of developing myxobacteria cells. These measurements have enabled us to develop a mathematical model...Full Text Available

2001-12-18

358

Measuring the thickness of the human cerebral cortex from magnetic resonance images  

UK PubMed Central (United Kingdom)

Accurate and automated methods for measuring the thickness of human cerebral cortex could provide powerful tools for diagnosing and studying a variety of neurodegenerative and psychiatric disorders....Full Text Available

2000-09-26

359

Measuring the efficacy of anti-malarial drugs in vivo: quantitative PCR measurement of parasite clearance  

UK PubMed Central (United Kingdom)

BackgroundArtemisinin-based combination therapy, currently considered the therapy of choice for uncomplicated Plasmodium falciparum malaria in endemic countries,...Full Text Available

360

Measuring quality of care in psychiatric emergencies: construction and evaluation of a Bayesian index.  

UK PubMed Central (United Kingdom)

OBJECTIVE. This study was conducted to determine whether an index for measuring quality of care for psychiatric emergencies is reliable and valid. DATA SOURCES/STUDY SETTING. The study used primary...Full Text Available

1993-06-01

361

Measuring properties of impulsive low frequency noise by different measuring set up. Shogekisei teishuhaon no keisokuki ni tsuite no kento  

Energy Technology Data Exchange (ETDEWEB)

Pollution abatement measures against impulsive low frequency noises including mine blasting noise require precise measurement of sound waveforms, but no instruments have been designed for that purpose, nor commercially available. This paper describes investigations on such instruments as noise level meters currently available commercially on their instrumental characteristics using indoor experiments and field measurements. The following matters were clarified: An instrument combining a microphone with an amplifier can not determine the response from the measuring system from the respective frequency characteristics alone, and requires a discussion on the overall response from the measuring system. A preferred noise level meter would be an instrument that has the lower limit for the frequency characteristics of the microphone extended to several hertz, and ...

1991-11-25

362

Measuring IBS patient reported outcomes with an abdominal pain numeric rating scale: results from the proof cohort  

UK PubMed Central (United Kingdom)

BackgroundControversy exists about how to effectively measure patient reported outcomes in IBS clinical trials. Pain numeric rating scales (NRS) are widely used in...Full Text Available

2009-12-01

363

Measuring Dimensions of Body Connection: Body Awareness and Bodily Dissociation  

UK PubMed Central (United Kingdom)

ObjectiveThis study aimed to test the preliminary psychometric properties of the Scale of Body Connection (SBC), a 20-item self-report measure, designed to assess...Full Text Available

2007-11-01

364

Measurements of the CKM angle $\\gamma/\\phi_{3}$ at B-factories  

CERN Document Server

The CKM angle $\\gamma/\\phi_{3}$ had been measured by two B-factories, the PEPII collider for the BaBar experiment and the KEKB collider for the Belle experiments. The present paper reports recent progress in $\\gamma/\\phi_{3}$.

2011-01-01

365

Measurements of accurate x-ray scattering data of protein solutions using small stationary sample cells  

UK PubMed Central (United Kingdom)

In this paper, we report a method of precise in situ x-ray scattering measurements on protein solutions using small stationary sample cells. Although reduction in the radiation damage...Full Text Available

2009-01-01

366

Measurement of the quadriceps femoris muscle using magnetic resonance and ultrasound imaging.  

UK PubMed Central (United Kingdom)

OBJECTIVES: To define a method for measurement of the cross sectional area and volume of the quadriceps femoris muscle using magnetic resonance imaging (MRI) in conjunction with stereology, and to compare...Full Text Available

1997-03-01

367

Measurement of the Water Potential of Stored Potato Tubers 1  

UK PubMed Central (United Kingdom)

A method of measuring the water potential of stored potato tubers (Solanum tuberosum L.) was needed to investigate the relationship of bacterial soft rot in tubers to water potential....Full Text Available

1985-11-01

368

Measurement of cosmic ray neutron spectrum at sea level  

International Nuclear Information System (INIS)

The cosmic ray neutron spectrum at sea level has been measured by the method of pulse shape discrimination in anthracene scintillator. The exponent of the differential spectrum was found to be 2.2+-0.1. (Auth.).

369

Measurement of body fat using leg to leg bioimpedance  

UK PubMed Central (United Kingdom)

AIMS—(1) To validate a leg to leg bioimpedance analysis (BIA) device in the measurement of body composition in children by assessment of its agreement with dual energy x...Full Text Available

2001-09-01

370

Measurement of Electrical Conductivity for a Biomass Fire  

UK PubMed Central (United Kingdom)

A controlled fire burner was constructed where various natural vegetation species could be used as fuel. The burner was equipped with thermocouples to measure fuel surface temperature and used as a...Full Text Available

371

Matrix diffusion studies by electrical conductivity methods. Comparison between laboratory and in-situ measurements  

Energy Technology Data Exchange (ETDEWEB)

Traditional laboratory diffusion experiments in rock material are time consuming, and quite small samples are generally used. Electrical conductivity measurements, on the other hand, provide a fast means for examining transport properties in rock and allow measurements on larger samples as well. Laboratory measurements using electrical conductivity give results that compare well to those from traditional diffusion experiments. The measurement of the electrical resistivity in the rock surrounding a borehole is a standard method for the detection of water conducting fractures. If these data could be correlated to matrix diffusion properties, in-situ diffusion data from large areas could be obtained. This would be valuable because it would make it possible to obtain data very early in future investigations of potentially suitable sites for a repository. This study compares laboratory electrical ...

1998-09-01

372

Mass spectrometric characterization of high-temperature outgassing of anisotropic pyrolytic boron nitride  

International Nuclear Information System (INIS)

This paper describes a system for fast mass spectrometric characterization of high-temperature outgassing measurements and measuring the total quantity of gas evolved for boron nitride. 2 references, 1 figure, 2 tables.

373

Maskirovka: The Soviet System of Camouflage.  

Science.gov (United States)

In this paper, the author discusses the Soviet system of camouflage measures. While the Russian word maskirovka, which is usually translated as camouflage, is used by the Soviets to describe these measures, much more is encompassed in what the author call...

1981-01-01

374

Low grade inflammation, as evidenced by basal high sensitivity CRP, is not correlated to outcome measures in IVF  

UK PubMed Central (United Kingdom)

PurposeTo assess the relationship between low-grade inflammation, measured as basal high sensitivity (hs)-CRP, and IVF outcome.MethodsWe recruited...Full Text Available

2008-08-01

375

Interrater Reliability of Isokinetic Measures of Knee Flexion and Extension  

UK PubMed Central (United Kingdom)

The purpose of this investigation was to determine the interrater reliability of peak torque and total work values obtained with isokinetic measures of knee flexion and extension. Eight male and eight...Full Text Available

1995-06-01

376

Initial Report of the Cancer PROMIS Supplement Sexual Function Committee: Review of Sexual Function Measures and Domains Used in Oncology  

UK PubMed Central (United Kingdom)

ObjectiveThis report describes initial activities of the Cancer Patient-Reported Outcomes Measurement Information System (PROMIS) Sexual Function domain group (CaPS-SF),...Full Text Available

2009-03-15

377

First Measurements of the Inclined Boron Layer Thermal-Neutron Detector for Reflectometry  

Energy Technology Data Exchange (ETDEWEB)

A prototype detector based on the inclined boron layer principle is introduced. For typical measurement conditions at the Liquids Reflectometer at the Spallation Neutron Source, its count rate capability is shown to be superior to that of the current detector by nearly two orders of magnitude.

2010-01-01

378

Ecological relevance of air pollution abatement measures as a decision aid  

Energy Technology Data Exchange (ETDEWEB)

Air pollution abatement measures are not an end in themselves, and undesirable side effects should be taken into account. The proposed emission index takes into account the total emissions caused by a technical project as well as the effects of the individual pollutants.

1983-01-01

379

Does It Matter What You Measure? Neighbourhood Effects in a Canadian Setting  

UK PubMed Central (United Kingdom)

Data from 8,032 Manitoba respondents to the 1996/97 Canadian National Population Health Survey were linked to the 1996 census to study whether measures of morbidity, both self-reported and objectively...Full Text Available

2010-08-01

380

Development and Validation of the Convalescence And Recovery Evaluation (CARE) for Measuring Quality of Life after Surgery  

UK PubMed Central (United Kingdom)

PurposeTo develop a generic instrument for measuring short-term health status in the recovery period among patients undergoing abdominal and pelvic surgery.Full Text Available

2008-08-01

381

Crosscheck of different techniques for two dimensional power spectral density measurements of x-ray optics  

Energy Technology Data Exchange (ETDEWEB)

The consistency of different instruments and methods for measuring two-dimensional (2D) power spectral density (PSD) distributions are investigated. The instruments are an interferometric microscope, an atomic force microscope (AFM) and the X-ray Reflectivity and Scattering experimental facility, all available at Lawrence Berkeley National Laboratory. The measurements were performed with a gold-coated mirror with a highly polished stainless steel substrate. It was shown that these three techniques provide essentially consistent results. For the stainless steel mirror, an envelope over all measured PSD distributions can be described with an inverse power-law PSD function. It is also shown that the measurements can be corrected for the specific spatial frequency dependent systematic errors of the instruments. The AFM and the X-ray scattering measurements were used to determine the ...

2005-07-12

382

Cross-sectional measures and modelled estimates of blood alcohol levels in UK nightlife and their relationships with drinking behaviours and observed signs of inebriation  

UK PubMed Central (United Kingdom)

BackgroundManagement of nightlife in UK cities focuses on creating safe places for individuals to drink. Little is known about intoxication levels as measuring total alcohol consumption...Full Text Available

383

Cross-check of different techniques for two-dimensional powerspectral density measurements of X-ray optics  

Energy Technology Data Exchange (ETDEWEB)

The consistency of different instruments and methods for measuring two-dimensional (2D) power spectral density (PSD) distributions are investigated. The instruments are an interferometric microscope, an atomic force microscope (AFM) and the X-ray Reflectivity and Scattering experimental facility, all available at Lawrence Berkeley National Laboratory. The measurements were performed with a gold-coated mirror with a highly polished stainless steel substrate. It was shown that these three techniques provide essentially consistent results. For the stainless steel mirror, an envelope over all measured PSD distributions can be described with an inverse power-law PSD function. It is also shown that the measurements can be corrected for the specific spatial frequency dependent systematic errors of the instruments. The AFM and the X-ray scattering measurements were used to determine the ...

2005-04-17

384

Continuous measurement of residual activity of an amine solution used for acid gas absorption  

Energy Technology Data Exchange (ETDEWEB)

Concentration of an amine solution for removal of hydrogen sulfides and carbon dioxide from natural gas, is tested by carbon dioxide absorption measurement in an apparatus allowing complete reaction to give reliable results.

1988-05-27

385

Comparison of Soil Surface Temperature Measurements by Means of Standard Soil Mercury Thermometers and a Barnes Prt-5 Infrared Thermometer.  

Science.gov (United States)

A short account is given of the difficulties encountered in temperature measurement of boundary layers and a comparison of two types of thermometers, an infrared radiometer and mercury in glass thermometer. (Author)

1972-01-01

386

Comparative evaluation of similarity measures for the rigid registration of multi-modal head images  

Energy Technology Data Exchange (ETDEWEB)

Image registrations that are based on similarity measures simply adjust the parameters of an appropriate spatial transformation model until the similarity measure reaches an optimum. The numerous similarity measures that have been proposed in the past are differently sensitive to imaging modality, image content and differences in the image content, selection of the floating and target image, partial image overlap, etc. In this paper, we evaluate and compare 12 similarity measures for the rigid registration. To study the impact of different imaging modalities on the behavior of similarity measures, we have used 16 CT/MR and 6 PET/MR image pairs with known 'gold standard' registrations. The results for the PET/MR registration and for the registration of CT to both rectified and unrectified MR images indicate that mutual information, normalized mutual information and ...

2007-09-21

387

Clinical Correlates to Laboratory Measures for use in Non-Contact Anterior Cruciate Ligament Injury Risk Prediction Algorithm  

UK PubMed Central (United Kingdom)

BackgroundProspective measures of high knee abduction moment during landing identify female athletes at high risk for non-contact anterior cruciate ligament injury....Full Text Available

2010-08-01

388

Bedload measurements, East Fork River, Wyoming  

UK PubMed Central (United Kingdom)

A bedload trap in the riverbed provided direct quantitative measurement of debris-transport rate in the East Fork River, Wyoming, a basin of 466 km2 drainage area. Traction load moves only...Full Text Available

1976-04-01

389

Augmenting Clinical Evaluation of Hemiparetic Arm Movement With a Laboratory-Based Quantitative Measurement of Kinematics as a Function of Limb Loading  

UK PubMed Central (United Kingdom)

BackgroundKinematic and kinetic measurements used in laboratory settings can quantify upper extremity movement impairment following stroke, but their relationship...Full Text Available

2008-01-01

390

Assessment of a bone biopsy technique for measuring tiludronate in horses: A preliminary study  

UK PubMed Central (United Kingdom)

This study assessed the feasibility of measuring tiludronate in horses using a minimally invasive bone biopsy technique. Eight horses were treated with intravenous (IV) tiludronate [1 mg/kg bodyweight...Full Text Available

2011-04-01

391

A trace gas technique for measuring clothing microclimate air exchange rates  

UK PubMed Central (United Kingdom)

Crockford, G. W., Crowder, M., and Prestidge, S. P. (1972).Brit. J. industr. Med.,29, 378-386. A trace gas technique for measuring clothing microclimate...Full Text Available

1972-10-01

392

A new method to measure necrotic core and calcium content in coronary plaques using intravascular ultrasound radiofrequency-based analysis  

UK PubMed Central (United Kingdom)

Although previous intravascular ultrasound (IVUS) radiofrequency-based analysis data showed acceptable reproducibility for plaque composition, measurements are not easily obtained, particularly that...Full Text Available

2010-04-01

393

ZZ KASHIL-E6, 175 N, 42 Gamma Groups Cross Sections in MATXS Format Based on ENDF/B-VI.5 for Shielding Applications  

International Nuclear Information System (INIS)

1 - Description of program or function: Format: MATXS; Number of groups: 175 neutron-, 42 photon-groups; 176 Nuclides: 1-H-1, 1-H-2, 1-H-3, 2-He-3, 2-He-4, 3-Li-6, 3-Li-7, 4-Be-9, 5-B-10, 5-B-11, 6-C- nat., 7-N-14, 7-N-15, 8-O-16, 8-O-17, 9-F-19, 11-Na-23, 12-Mg-nat., 13-Al-27, 14-Si-nat., 14-Si-28, 14-Si-29, 14-Si-30, 15-P-31, 16-S-32, 17-Cl-nat., 19-K-nat., 20-Ca-nat., 21-Sc-45, 22-Ti-nat., 23-V-nat., 24-Cr-50, 24-Cr-52, 24-Cr-53, 24-Cr-54, 25-Mn-25, 26-Fe-54, 26-Fe-56, 26-Fe-57, 26-Fe-58, 27-Co-59, 28-Ni-58, 28-Ni-60, 28-Ni-61, 28-Ni-62, 28-Ni-64, 29-Cu-63, 29-Cu-65, 31-Ga-nat., 39-Y-89, 40-Zr-nat., 40-Zr-90, 40-Zr-91, 40-Zr-92, 40-Zr-94, 40-Zr-96, 41-Nb-93, 42-Mo-nat., 46-Pd-102, 46-Pd-104, 46-Pd-105, 46-Pd-106, 46-Pd-108, 46-Pd-110, 47-Ag-107, 47-Ag-109, 48-Cd-106, 48-Cd-108, 48-Cd-110, 48-Cd-112, 48-Cd-113, 48-Cd-114, 48-Cd-116, 49-In-nat., 53-I-127, 54-Xe-124, 54-Xe-126, 54-Xe-128, 54-Xe-129, 54-Xe-130, 54-Xe-131, 54-Xe-132, 54-Xe-134, 54-Xe-136, 55-Cs-133, ...

394

The development of automatic surface dose-rate measuring and recording system for radioactive waste drum  

International Nuclear Information System (INIS)

The system which is performed the transportation and measurement of drum automatically to measure the surface dose-rate of radioactive waste drum and can inspect place of contaminated sources and precise dose-rate within a drum according to measuring many places equally at the same time has been developed. It is expected that the system be used to minimized radiation exposure of workers and manage the drum effectively according to established at the production facilities as well as the radioactive waste treatment facilities. (author). 7 refs., 9 tabs., 16 figs.

395

The Measurement of Air-Sea Fluxes  

Science.gov (United States)

... The micrometeorological community often expresses these relations in resistance law terms (Garratt and Hicks, 1973; Hicks et al., 1985) ...

1990-10-09

396

The Dynamic Analog Scale: A generic method for single-item measurement  

British Library Electronic Table of Contents (United Kingdom)

The Dynamic Analog Scale (DAS) is introduced as a technique for generating single-item measures of personality traits. The DAS is comprised of extensive trait definitions and an analog scale on which respondents simultaneously rate themselves and others. In two studies the Big Five personality traits were assessed with the DAS and compared to a multiple-item questionnaire that measured the same traits. Statistical analysis supported the validity of the DAS for predicting self-reported behavioral acts, drinking behaviors, affect, and religiosity in ways similar to the multiple-item questionnaire. Consistent with previous research, both studies supported the viability of measuring personality traits with single items.

2011-01-01

397

Temperature measurements via narrow line laser absorption of carbon dioxide  

Energy Technology Data Exchange (ETDEWEB)

Theoretical development for temperature measurements via narrow line, infrared absorption of carbon dioxide (CO{sub 2}) is presented. The proposed technique is based on rapid-scanning of two adjacent absorption line shapes. Spectroscopic considerations for sensitivity to temperature measurements are discussed. Several line pairs are evaluated, and the R(58) and R(60) transitions of the (00{sup 0}1){l_arrow}(00{sup 0}0) band are suggested for use in high temperature measurements for combustion systems.

1996-12-31

398

Technical report for fabrication and performance test of electrochemical/spectroscopic measurement system  

International Nuclear Information System (INIS)

Development of evaluation technology of electrochemical reactions is very essential to understand chemical behavior of actinides and lanthanides in molten salt media in relation to the development of Pyrochemical process. The on-line electrochemical/spectroscopic measurement system is to produce electrochemical parameters and thermodynamic parameters of actinides and lanthanides in molten salts by using spectroscopic techniques such as UV-VIS absorption as well as electrochemical in-situ measurement techniques. The on-line electrochemical/spectroscopic measurement system can be applied to understand the chemical reactions and oxidation states of actinides and lanthanides in molten salts eventually for the Pyrochemical process

2006-09-01

399

Superconducting properties of metallic superlattices  

Energy Technology Data Exchange (ETDEWEB)

The preparation by sputtering of artificial metallic superlattices is described, as are the results of x-ray structural determinations. Tunneling and resistivity measurements on these materials are reported.

1987-01-01

400

Solar-cell airplane Solair 1  

Energy Technology Data Exchange (ETDEWEB)

The article describes the Solair 1 solar cell-powered aircraft. Measures to reduce the weight of the craft are cited.

1983-03-01

401

Reynolds Number Effects in Transonic Flow  

Science.gov (United States)

... of drag measurements with the AGARD Nozzle Afterbody ... are discussed separately from flows with a ... bubbles introduce typical flow phenomena that ...

1988-12-01

402

Replication in the Harp File System  

Science.gov (United States)

... i3a. ... gives performance measurements for various benchmarks, and compares the performance of Harp with the standard implementation of NFS in ...

1981-07-01

403

Reactor Neutrino Experiments  

CERN Document Server

Precisely measuring $\\theta_{13}$ is one of the highest priority in neutrino oscillation study. Reactor experiments can cleanly determine $\\theta_{13}$. Past reactor neutrino experiments are reviewed and status of next precision $\\theta_{13}$ experiments are presented. Daya Bay is designed to measure $\\sin^22\\theta_{13}$ to better than 0.01 and Double Chooz and RENO are designed to measure it to 0.02-0.03. All are heading to full operation in 2010. Recent improvements in neutrino moment measurement are also briefed.

2007-01-01

404

Physical and Computational Investigation of the Wall Pressure ...  

Science.gov (United States)

... Although other authors had made cross-spectral density measurements, Corcos pointed to the importance of this function as indicative of the true ...

1990-04-26

405

Performance measurements of the Pionier-I 15 m VAWT. Prestatiemetingen aan de Pionier-I 15 m VAWT  

Energy Technology Data Exchange (ETDEWEB)

Pionier-I is a vertical axis wind turbine (VAWT) of the Darrieus-type with a diameter of 15 m. In the month of September 1983 performance and efficiency were measured. Measurements were done with constant rotational speed and with constant tip speed ratio. For the calculation of the possible (theoretical) output of electric power an anemometer was present. Measurement results are conditioned to one digital signal and processed by a microcomputer (Apple II). It becomes evident that the yearly energy output of the Pionier-I is quite well comparable with that of a horizontal axis turbine with the same diameter.

1983-01-01

406

PRODUCTION ENGINEERING MEASURE RELIABILITY ...  

Science.gov (United States)

... without the problem of purple plague. The Au-Ni-In evaporated ... surface and bonding degradation (purple plague) St step-stress ...

1963-09-30

408

On-line partial discharge measurements and off-line dielectric spectroscopy measurements of six 115 kV XLPE cable systems  

Energy Technology Data Exchange (ETDEWEB)

This paper reported on a study in which partial discharge (PD) measurements were performed on 6 underground transmission cable circuits to determine the effectiveness of PD measurements on fluid fill cables. The cables were between 37 and 56 years old. PD activity was detected from the terminations of H11L and H3L Cable 2. However, for cables from H3L Basin TS to Mill Street junction, PD activity was detected originating from within the main cable insulation.

2009-07-01

409

Noncommissioned Officer Education System (NCOES) ...  

Science.gov (United States)

... While some measures were suggested as counseling tools to guide and influence ... it be awarded as part of the NCO Evaluation Report (NCOER). ...

2008-11-01

410

Multiplication measurements for initial startup with the mockup core for the FFTF  

International Nuclear Information System (INIS)

... fftf reactor mockup multiplication factors reactivity worths reactor cores reactor

1974-10-27

411

Method for determining the concentration of atomic species in gases and solids  

Energy Technology Data Exchange (ETDEWEB)

Method for determining the concentration of atomic species in gases and solids. Measurement of at least two emission intensities from a species in a plasma containing the species after a sufficient time period has elapsed after the generation of the plasma and during a second time period, permits an instantaneous temperature to be established within the sample. The concentration of the atomic species to be determined is then derived from the known emission intensity of a predetermined concentration of that species in the sample at the measured temperature, a quantity which is measured prior to the determination of the unknown concentration, and the actual measured emission from the unknown species, or by this latter emission and the emission intensity of a species having known concentration within the sample.

1999-01-01

412

Meteorological Measurement Guide  

Science.gov (United States)

... 2-22 Page 31. The mercury barometer operates on the principle of air pressure forcing the mercury column up an evacuated tube. ...

1992-01-01

413

Measuring relative probability of Am-242 #beta#-decay  

International Nuclear Information System (INIS)

... americium 241 americium 242 beta decay chain reactions integral doses mass

414

Measurement of the energy dependence of the neutron fission cross section of /sup 242/Am/sup m/  

Energy Technology Data Exchange (ETDEWEB)

Measurements were made of the cross section for /sup 242/Am/sup m/ fission induced by neutrons in the energy range 0.04< or =E/sub n/< or =4.52 MeV as well as by neutrons with E/sub n/roughly-equal14.8 MeV. An electrostatic generator and a low-voltage accelerating tube were used to generate the quasimonochromatic neutrons. Measurements in the low-energy region were made by using the time-of-flight technique in neutrons from a nuclear explosion. Results of the measurements are compared with previously published data.

1981-03-01

417

Measurement of low-energy laser pulse duration in femtosecond range  

International Nuclear Information System (INIS)

Measurements of low-energy (#approx#10"- "1"0 J) femtosecond laser pulse durations have been carried out on the basis of second-order autocorrelation function analysis. The scheme of non collinear second harmonic generation realized in KDP crystal has been used for increasing of the measurement contrast and accuracy. Proposed scheme can be used for measurements in wide enough ranges of laser pulse durations (from tens femto seconds to hundreds picoseconds) and energies. (authors)

418

Measurement of low-energy antiproton detection efficiency in BESS below 1 GeV  

Energy Technology Data Exchange (ETDEWEB)

An accelerator experiment was performed using a low-energy antiproton beam to measure antiproton detection efficiency of BESS, a balloon-borne spectrometer with a superconducting solenoid. Measured efficiencies showed good agreement with calculated ones derived from the BESS Monte Carlo simulation based on GEANT/GHEISHA. With detailed verification of the BESS simulation, the relative systematic error of detection efficiency derived from the BESS simulation has been determined to be {+-}5%, compared with the previous estimation of {+-}15% which was the dominant uncertainty for measurements of cosmic-ray antiproton flux.

2002-08-21

421

Influence of HNS on the Microstructure and Properties of Cast ...  

Science.gov (United States)

... The ultimate compressive strength was measured, and values for Young's modulus were calculated from the linear portion of the test curve. ...

1981-04-01

422

Improved SSAMS performance  

British Library Electronic Table of Contents (United Kingdom)

We operate a new NEC 250kV single-stage accelerator mass spectrometer (SSAMS) next to our established 5MV tandem. This permits good comparison of 14C-AMS and challenges SSAMS performance. Initial SSAMS ion-optical deficiencies have been addressed by shimming the injection magnet and 3permil 14C/13C measurement with background limited by sample chemistry is routine. Higher-precision analysis is also achievable. A problematic measurement interference remains, however. The small spectrometer was procured to add measurement capacity, and for experiments with positive ions, but is now the preferred instrument for both convenience and measurement quality.

2010-01-01

424

High emittance coverglass  

International Nuclear Information System (INIS)

The authors describe measurements of emittance made on samples of solar cell coverglasses incorporating new coatings both on C-7940 fused silica and on CMX ceria doped microsheet. Samples of a conventional, MgF_2 coating on the same two types of coverglass substrates were included in the measurements as controls. Measurements were made by the calorimetric method of total hemispherical emittance within a cooled chamber as well as by the more common infrared reflectance method. Emittance enhancements from 1 to 4% were measured for the new coatings.

1988-09-26

425

Halon Flightline Extinguisher Evaluation: Data Supporting ...  

Science.gov (United States)

... Nacelle temperature was measured with a hand-held infrared thermometer for this series of evaluations instead of an installed thermocouple. 1 ...

2008-02-01

426

Forthcoming (n, #gamma#) measurements on the Fe and Ni isotopes at CERN n_TOF  

International Nuclear Information System (INIS)

An overview of the past, present and future research activities at the CERN neutron time of flight facility n_TOF is given, with special focus on the astrophysical aspects. During the first campaign (Phase I), neutron capture cross sections of relevance for several aspects of the s-process nucleosynthesis have been measured. A second campaign has recently started (Phase II), aiming at the study of the weak s-process component via accurate (n,#gamma#) measurements of the Fe and Ni isotopes. Some changes in the facility will allow us to perform these measurements with improved experimental conditions.

2010-01-01

428

Findings of long-term SO/sub 2/ measurements in Stuttgart  

Energy Technology Data Exchange (ETDEWEB)

SO/sub 2/ concentrations in the Stuttgart air have been measured continuously since 1965. The two measuring points were located at the bottom of the Stuttgart city basin and 900 m east on the side of one of the surrounding hills. Long-term curves of pollutant loads have been established in consideration of meteorological parameters, as well as curves showing the average daily, weekly, and yearly pollution. The information thus gained may help to plan air pollution abatement measures in city planning.

1982-02-01

429

Environmental radiation measurements using TLD in and around AERE, Dhaka. Technical note  

Energy Technology Data Exchange (ETDEWEB)

The external background radiation level in and around the Atomic Energy Research Establishment (AERE) in Dhaka has been measured. The measurements were performed using lithium fluoride (LiF) thermoluminescence dosemeters (TLD-100) at 32 locations, all one metre above the ground. The annual average dose rate measured in the AERE environs was 1.74+-0.23 mGy.y/sup -1/ in air, based on analysis of thermoluminescence dosemeter data collected from 1982 to 1984.

1986-01-01

430

Direct Measurements of the Branching Fractions for $D^0 \\to K^-e^+\  

CERN Document Server

The absolute branching fractions for the decays $D^0 \\to K^-e ^+\

2004-01-01

431

DEFENSE METALS INFORMATION CENTER SELECTED ...  

Science.gov (United States)

... The total hemispherical emittance rig has been returned to service and the quality of temperature measurement has been investigated. ...

1963-11-01

432

Complex fluid analysis with the advanced distillation curve approach.  

Science.gov (United States)

An improved method for measuring distillation curves reveals the physicochemical properties of complex fluids such as fuels. PMID:20041713

2010-02-01

433

Coefficient of Variation Spectral Analysis: An Application to ...  

Science.gov (United States)

... A major problem in the analysis of power spectral density measurements is distinguishing between narrowband spectral components of interest ...

1983-05-03

434

Cleaning Aged EPDM Rubber Roofing Membrane Material for ...  

Science.gov (United States)

... 5. The results of the bond strength measurements were compared to the surface cleanness of the aged EPDM as determined by the specified ...

1992-08-01

438

A measurement of the cross section for electron impact ionization of Ar"2"+, Kr"2"+ and Xe"2"+  

International Nuclear Information System (INIS)

The crossed electron-ion beams technique was used to measure absolute cross sections for single ionization of Ar"2"+, Kr"2"+ and Xe"2"+ ions at electron energies ranging from threshold to 2000 eV. In contrast to some previous measurements, the metastable contents of the ion beams were small even in the case of Xe"2"+. All measured cross section curves show significant contributions from excitation-autoionization and possibly direct ionization of inner-shell electrons. There is evidence for resonance-excitation-double-autoionization in the case of Xe"2"+. (author).

439
440

Time-resolved measurement of a self-amplified free-electron laser  

International Nuclear Information System (INIS)

We report on a time-resolved measurement of self-amplified spontaneous emission free-electron laser (FEL) pulses. We observed that the spikes in such FEL pulses have an intrinsic positive chirp and the energy chirp in the electron bunch mapped directly into the FEL output. The measurement also provides rich information on the statistics of the FEL pulses.

2003-07-11

441

The electrical measurement of AC losses in a three-phase tri-axial superconducting cable  

International Nuclear Information System (INIS)

In a three-phase tri-axial cable, the magnetic interaction between the phases makes the loss measurement by an electromagnetic method very complex. We developed the theoretical background showing that three-phase AC loss measurements by the electromagnetic method are, in principle, possible. We then implemented this theory in practical measurements on a 3 m long, tri-axial cable fabricated from RABiTS (rolling-assisted biaxially textured substrate) coated conductor. Initially, the proposed measurement technique was implemented in the simpler cases when the three cable phases are 180"0 out of phase, i.e. (0"0, 180"0, 360"0) or (0"0, 360"0, 180"0) rather than (0"0, 120"0, 240"0) as in a traditional three-phase system. For these cases, the currents in the phases are either in phase (360"0 phase difference) or anti-phase (180"0 phase difference). These are essentially single-phase ...

2010-09-01

442

Study on reactivity measurement by the Feynman-#alpha# method  

International Nuclear Information System (INIS)

The Feynman-#alpha# method was applied to measurement of reactivity and the ability of this method for a real-time reactivity monitoring system was assessed. In the experiment, all measured data by BF_3 detectors were stored in a multi-channel scaler controlled by a personal computer, and they were analyzed to obtain prompt neutron decay constant (#alpha#) and reactivity with consideration of dead time of detector. It was found that #alpha# could be obtained almost in a real-time even for both positive and negative reactivities by the present experimental technique. (author).

1996-09-01

443

Some tests on measuring methods for indoor radon using activated charcoal  

Energy Technology Data Exchange (ETDEWEB)

Two methods for measuring indoor radon concentrations using activated charcoal have been tested. The first method is the well-known technique with direct gamma-measurements on the exposed canister after the sampling period. The other method uses a thermoluminescence dosemeter placed in the charcoal canister, giving an integrated value of the radon concentration.

1985-10-01

444

Some optimization measurements and parameters of a radionuclide X-ray fluorescence spectrometer  

International Nuclear Information System (INIS)

An irradiation head with sample holders is described and measurement geometry is reported. Measurements were made for optimizing the distance between the source and the sample and for optimizing the sample diameter. The optimal distance between the source and the sample does not depend on the collimator diameter. The sample diameter should not exceed 30 - 35 mm. Sensitivity and detection limits were determined for Zn, Pb and Br and calibration curves were plotted. (M.D.) 6 figs., 2 tabs., 4 refs.

1986-01-01

445

Remote participation technical infrastructure for the JET facilities under EFDA  

Energy Technology Data Exchange (ETDEWEB)

The new collaborative exploitation of the JET Facilities requires suitable technical tools and infrastructure measures to enable the Remote Participation of scientists from all European Fusion labs. Such measures are being gradually introduced. They comprise of a toolkit for Remote Data Access, Remote Computer Access and for teleconferencing, and of infrastructure measures that address network connectivity, network security, shared documentation and technical support.

2001-10-01

446

Remote measurement of methane in coal mines: a review  

Energy Technology Data Exchange (ETDEWEB)

The authors identify a need for a device which can remotely measure methane in coal mines. Similar techniques which have been used to measure atmospheric pollutants are discussed. These techniques include adsorption, Raman scattering and fluorescence. While differential adsorption and Raman scattering techniques have potential there are a number of problems to be resolved before they could be applied effectively. It is felt that an area which may provide suitable technology sometime in the future is in the field of laser sources. 6 refs., 4 tabs.

1987-02-01

447

Radon measurements in the interior of the great pyramid  

Energy Technology Data Exchange (ETDEWEB)

Radon concentration measurements were made in the interior of the great pyramid of ''Cheops'' at Giza. Measurements were carried out using CR-39 as a solid state nuclear track detector. The CR-39 sheets were placed inside the Queen's and King's chambers and along the ascending corridor leading to them. An evaluation of the radon concentration is presented and discussed. (author).

1991-01-01

448

Radon measurements in the interior of the great pyramid  

International Nuclear Information System (INIS)

Radon concentration measurements were made in the interior of the great pyramid of ''Cheops'' at Giza. Measurements were carried out using CR-39 as a solid state nuclear track detector. The CR-39 sheets were placed inside the Queen's and King's chambers and along the ascending corridor leading to them. An evaluation of the radon concentration is presented and discussed. (author).

449

Radon concentration measurements in the soil  

International Nuclear Information System (INIS)

Radon concentration measurement in the ground can be used for the prospecting for uranium and earthquake prediction. Some results of radon concentration measurement in the soil are presented here. The moisture condensation at the detector surface can affect on the detection efficiency. Due to this problem we tested a few filter papers on water permeability. The ratio of track densities on solid state nuclear track detector (SSNTD) in the open and the closed diffusion chamber is also determined. (author)

450

Quantum locking of mirrors in interferometric measurements  

International Nuclear Information System (INIS)

We discuss the use of active control to reduce mirror position fluctuations at the quantum level. We have shown in a recent experiment that it is possible to reduce the thermal noise of a mirror by measuring and controlling its motion with an optomechanical sensor based on a high-finesse optical cavity. This approach can be extended to lock the mirror motion at the quantum level, and to suppress the quantum effects of radiation pressure in interferometric measurements such as gravitational-wave detectors. The sensitivity improvement is furthermore independent of losses in the interferometer.

2004-03-07

451

Properties as measurands: An overview and some critical issues  

International Nuclear Information System (INIS)

Measurement results are interpreted as (sets of) values attributed to measurands, i.e., quantities (intended to be measured), i.e., properties (having a magnitude that can be expressed as a number and a reference). This relatively simple conceptual structure hides some important issues for measurement science, that the lecture will tentatively explore with a systematic reference to the International vocabulary of metrology - Basic and general concepts and associated terms (VIM) and its possible future developments.

2010-07-01

452

Possibilities of rayleigh-taylor instability measurement by X-ray phase imaging  

International Nuclear Information System (INIS)

X-ray imaging is a very useful plasma diagnostic method. A theoretical analysis of the x-ray phase imaging in the method based on Fresnel diffraction is given. The authors show it is a linear band pass filter, a property suit for Rayleigh-Taylor (R-T) instability measurement. The evaluation permits the possibility of R-T instability measurement in x-ray phase imaging

453

Patient Monitoring during Mechanotherapy Based on Electrocutaneous Impedance Measurement  

British Library Electronic Table of Contents (United Kingdom)

Patient monitoring during mechanotherapy based on electrocutaneous impedance measurement is discussed. Methods implemented by the Alpharhythmica computer-assisted system are described. Mechanotherapy modifies electrocutaneous impedance as compared to other parameters: heart rate, arterial pressure, and body temperature. Real time criteria of mechanotherapy efficacy based on electrocutaneous impedance measurement are suggested. Results of electrocutaneous impedance monitoring are presented.

2011-01-01

454

Optical measurement of electron bunching in vacuum  

International Nuclear Information System (INIS)

We report the homodyne detection of phase modulation sidebands induced on a laser beam by a coherently bunched electron beam. This provides a sensitive and nonperturbing measurement of complex Fourier time series components of the electron density. A proof-of-principle measurement of the microwave frequency component of electron density in a crossed-field device, which agrees well with a calculation of the same quantity, is reported.

455

Neutron detection techniques for plasma diagnostics at the Joint European Torus (JET)  

International Nuclear Information System (INIS)

The importance of neutron measurements both as a succinct measure of the progress to fusion ignition using the magnetic confinement route and also as a diagnostic of plasma conditions is discussed. The various neutron diagnostic systems that have been or are being constructed by AERE Harwell for JET are described. The properties to be measured by such diagnostics are clearly identified and some results obtained with the installed diagnostics during d-d plasmas are presented.

456

Measuring-Basis Encrypted Quantum Key Distribution with Four-State Systems  

International Nuclear Information System (INIS)

A measuring-basis encrypted quantum key distribution scheme is proposed by using twelve nonorthogonal states in a four-state system and the measuring-basis encryption technique. In this scheme, two bits of classical information can be encoded on one four-state particle and the transmitted particles can be fully used.

2007-01-15

457

Measurements of radioactivity in Jamaican building materials and gamma dose equivalents in a prototype red mud house  

International Nuclear Information System (INIS)

Concentrations of 226Ra, 232Th, and 40K measured in bauxite waste, local building materials, and soils are presented and used in model equations to estimate the effective gamma dose-equivalent increments over background in the center of a standard-sized room in a prototype house. Calculated and measured values compare reasonably well.

458

Measurement of the fast neutron component in the beam of the NPL Thermal Neutron Column using a Bonner sphere spectrometer  

Energy Technology Data Exchange (ETDEWEB)

Following a recent refurbishment of the NPL Thermal Neutron Facility, the spectrum of the epithermal and fast neutron component of the beam produced by the thermal column of this facility was measured over the energy range from thermal to 20 MeV using a Bonner sphere spectrometry system. The effect of the presence of epithermal and fast neutrons on the measured response of commonly-used thermal neutron dosemeters was calculated. (author)

1999-05-01

459

Measurement of the fast neutron component in the beam of the NPL Thermal Neutron Column using a Bonner sphere spectrometer  

International Nuclear Information System (INIS)

Following a recent refurbishment of the NPL Thermal Neutron Facility, the spectrum of the epithermal and fast neutron component of the beam produced by the thermal column of this facility was measured over the energy range from thermal to 20 MeV using a Bonner sphere spectrometry system. The effect of the presence of epithermal and fast neutrons on the measured response of commonly-used thermal neutron dosemeters was calculated. (author)

460

Measurement of audible noise from transmission lines  

Energy Technology Data Exchange (ETDEWEB)

The audible noise produced by corona on high-voltage transmission lines has several characteristics that differentiate it from other community noises. Transmission line noise is quite broadband and has a significant high frequency content. Special instrumentation designed to measure this type of noise pollution is described. All measuring systems have the same three basic elements: a transducer, a processing device, and an output device. Recorders, microphone devices, frequency analyzers, and meteorological instrumentation are discussed.

1981-03-01

461

Laser induced fluorescence measurements of the mixing of fuel oil with air  

Energy Technology Data Exchange (ETDEWEB)

We report on measurements of the mixing of fuel oil with air at atmospheric pressure in an industrial premixed gas turbine burner. The concentration of the vaporized fuel oil was measured with laser induced fluorescence. We reason that the fuel oil concentration can be considered with good accuracy as proportional to the fluorescence intensity. (author) 6 fig., 3 refs.

1999-08-01

462

Hydrodynamic measurement of a single corrosion pit  

Energy Technology Data Exchange (ETDEWEB)

The hydrodynamics of gas evolution plays an important role in the pitting corrosion of metals. A new technique for the measurement of the local hydrodynamics caused by corrosion processes, using the atomic force microscope, has been presented in this work. The hydrodynamics of hydrogen evolution on Al surface due to pitting corrosion was studied. The characteristic features of the hydrodynamics are discussed. To the best of our knowledge this is the first local measurement of pitting corrosion hydrodynamics.

2004-11-01

463

Growth model and on-line measurement of pitting corrosion on carbon steel  

Energy Technology Data Exchange (ETDEWEB)

A growth model of pitting corrosion of carbon steel in cooling water systems was developed on microscopic observations of pits and electrochemical studies. Results of pitting corrosion measurements in laboratory and field conditions with the model, using a newly developed electrochemical device, are discussed. For an actual heat exchanger up to a year operation, the values of pitting depth estimated were in good agreement with the measured values.

1996-12-01

464

Experience with a digital noise analysis system in subcriticality measurements on a mockup of the FFTF  

Science.gov (United States)

From nuclear science symposium; San Francisco, California, USA (14 Nov 1973). A digital Fourier analyzer was programmed to perform reactor neutron noise analysis measurements and on-line processing of the data to obtain the steady-state reactivity. The system is suitable for recovering cross spectral density with low correlatedsignal component and for repetitive measurements with efficient use of reactor time. (auth)

1973-01-01

465

Estimation of gamma-absorption method for measurement of layers thickness in multi-layers articles  

International Nuclear Information System (INIS)

Certain problems of gamma-absorption method of measuring the thickness of layers in multi-layer items are analyzed. Two examples of solving the above-mentioned problems have been considered. One of them deals with a two-layer item, its integral thickness being known or measured in advance, the second example is referred to a two-layer item with unknown integral value

466

Dimensional metrology and positioning operations: basics for a spatial layout analysis of measurement systems  

CERN Document Server

Dimensional metrology and positioning operations are used in many fields of particle accelerator projects. This lecture gives the basic tools to designers in the field of measure by analysing the spatial layout of measurement systems since it is central to dimensional metrology as well as positioning operations. In a second part, a case study dedicated to a synchrotron storage ring is proposed from the detection of the magnetic centre of quadrupoles to the orbit definition of the ring.

2010-01-01

467

Characterization of polymers for microcellular foams  

Energy Technology Data Exchange (ETDEWEB)

We have measured, by {sup 1}H and {sup 13}C nuclear magnetic resonance (NMR), the percent deuteration, the tacticity and the purity of several polymers and one solvent used in the preparation of microcellular foams. The percent deuteration was measured for polystyrene, polyacrylonitrile and polyethylene. The tacticities of polystyrene and polyacrylonitrile were determined. The purity and degradation products of polyacrylonitrile and maleic anhydride were examined. This report documents the experimental procedures and results of these measurements.

1992-03-01

468

Annual meeting on nuclear technology '94. Technical session: Radioactivity measurement networks in Europe  

International Nuclear Information System (INIS)

The Chernobyl reactor accident has pronupted all European countries to rehabilitate their existing measurement and monitoring systems and to design and erect new ones. These systems are meant to ensure a rapid overview on the situation in case of an accident to adopt suitable actions for protection or prevention. 6 papers report on the state of such measurement systems in Europe, inparticular those in France (TELERAY), in Germany (IMIS) and in Switzerland (RADAIR). The IMIS-system is discussed for its extension to Eastern Germany. (HP).

469

A survey of Measured Group Theory  

CERN Document Server

The title refers to the area of research which studies infinite groups using measure-theoretic tools, and studies the restrictions that group structure imposes on ergodic theory of their actions. The paper is a survey of recent developments focused on the notion of Measure Equivalence between groups, and Orbit Equivalence between group actions. We discuss known invariants and classification results (rigidity) in both areas.

2009-01-01

470

A comparison of the predicted and measured gravitational stresses in VAWT (Vertical Axis Wind Turbine) blades  

Science.gov (United States)

During the erection of the Sandia 34-Meter VAWT Test Bed, the induced gravitational stress state in the turbine blades and their associated deflections were measured. This manuscript details the measurements that were taken on the Test Bed blades during erection and compares them to the stresses and deflections predicted by the NASTRAN finite element code.

1987-01-01

471

Transmission nuclear resonance fluorescence measurements of "2"3"8U in thick targets  

International Nuclear Information System (INIS)

Transmission nuclear resonance fluorescence measurements were made on targets consisting of Pb and depleted U with total areal densities near 86g/cm"2. The "2"3"8U content in the targets varied from 0% to 8.5% (atom fraction). The experiment demonstrates the capability of using transmission measurements as a non-destructive technique to identify and quantify the presence of an isotope in samples with thicknesses comparable to the average thickness of a nuclear fuel assembly. The experimental data also appear to demonstrate the process of notch refilling with a predictable intensity. Comparison of measured spectra to previous backscatter "2"3"8U measurements indicates general agreement in observed excited states. Evidence of two new "2"3"8U excited states and possibly a third state have also been observed.

2011-05-15

472

Resonant frequencies and Q factors of dielectric parallelepipeds by measurement and by FDTD  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the measurement and computation of the resonant frequencies and the associated Q factors of dielectric parallelepipeds made of high-permittivity, low-loss ceramic materials. Each resonance peak is measured separately with a fine frequency step. A curve-fitting method is used to accurately estimate the resonant frequency and 3 dB bandwidth from the somewhat noisy measured data. The finite-difference time-domain method is used to compute the initial portion of the backscattered field due to a Gaussian pulse plane wave. The time response is then extended to zero value by Prony`s method. The measured and computed data is compared for a parallelepiped resonator of permittivity 37.84.

1994-12-31

473

Relative luminosity measurement of the LHC with the ATLAS forward calorimeter  

CERN Document Server

In this paper it is shown that a measurement of the relative luminosity changes at the LHC may be obtained by analysing the currents drawn from the high voltage power supplies of the electromagnetic section of the forward calorimeter of the ATLAS detector. The method was verified with a reproduction of a small section of the ATLAS forward calorimeter using proton beams of known beam energies and variable intensities at the U-70 accelerator at IHEP in Protvino, Russia. The experimental setup and the data taking during a test beam run in April 2008 are described in detail. A comparison of the measured high voltage currents with reference measurements from beam intensity monitors shows a linear dependence on the beam intensity. The non-linearities are measured to be less than 0.5 % combining statistical and systematic uncertainties.

2010-01-01

474

Preliminary investigation of the /sup 252/Cf-source-driven noise analysis method of subcriticality measurement in LWR fuel storage and initial loading applications  

Energy Technology Data Exchange (ETDEWEB)

The ability of the /sup 252/Cf-source-driven neutron noise analysis method to measure subcriticality has been demonstrated in a variety of experimental configurations of fissile materials. Calculations for an approximately 4-m-dia configuration of light water reactor (LWR) fuel elements indicated the feasibility of measuring the subcriticality of large, loosely coupled arrays of LWR fuel elements by this same method. These analysis suggested application to the initial loading of both pressurized and boiling water reactors, zero-power testing of reactors (such as shutdown margin measurements after initial loading), light water reactor refueling, and safe storage of LWR spent fuel. In the fuel storage application, direct measurement of subcriticality in the actual fuel storage facilities provides the parameter which is directly related to criticality safety.

1984-01-01

475

Precision measurements of positronium decay rate and energy level  

CERN Document Server

Positronium is an ideal system for the research of the bound state QED. New precise measurement of orthopositronium decay rate has been performed with an accuracy of 150 ppm, and the result combined with the last three is 7.0401 +- 0.0007 mu s^-1. It is the first result to validate the 2nd order correction. The Hyper Fine Splitting of positronium is sensitive to the higher order corrections of the QED prediction and also to the new physics beyond Standard Model via the quantum oscillation into virtual photon. The discrepancy of 3.5 sigma is found recently between the measured values and the QED prediction (O(alpha^3)). It might be due to the contribution of the new physics or the systematic problems in the previous measurements: (non-thermalized Ps and non-uniformity of the magnetic field). We propose new methods to measure HFS precisely without the these uncertainties.

2008-01-01

476

On-line size and shape measurement techniques for hot steel rolling process; Netsukanatsuen kankyo ni taeru onrain sunpou{center_dot}keijo sokutei gijutsu  

Energy Technology Data Exchange (ETDEWEB)

Recent Kawasaki Steel's development on size and shape measurement techniques for hot steel rolling processes is reviewed. First, a precision enhancement technique for a laser distance meter is described, then its rugged structure necessary for measurement in such tough environment as hot rolling processes is described in detail. A plate length meters and an inter-stand sensors for a hot strip mill are shown as developed size measurement techniques. Furthermore, plate shape meters and laser profile gauges for H-beams are depicted as specific examples of shape measurement techniques. (author)

1999-12-01

477

Nuclear techniques for measuring moisture content in soil profiles  

International Nuclear Information System (INIS)

The prevailing severe shortage of animal feed in most of the developing countries could, to a considerable extent, be overcome through improved range management, which includes introduction of high yielding drought-resistant forage crops, development of adequate water conservation measures, and as far as possible growing annual forage crops on part of the vast areas of arable land currently left fallow each year. Year round measurements are essential for a good understanding of soil water and nutrients dynamics, which allow for adequate evaluation of pasture management alternatives. The methods most commonly used for moisture measurements in soil profiles are discussed because such measurements are likely to form an essential part of any investigation aimed at increasing animal feed production through the development of adequate pasture management practices. (author).

478

Measurement properties of the pressure biofeedback unit in the evaluation of transversus abdominis muscle activity: a systematic review  

British Library Electronic Table of Contents (United Kingdom)

Background: Measurements from pressure biofeedback units (PBUs) can be used to evaluate the activity of the transversus abdominis (TrA) muscle indirectly. These measurements can classify patients or monitor the progress of treatment programmes for people with low back pain. Objective: To systematically review studies on the measurement properties of PBUs for the assessment of TrA activity. Data sources: Eligible studies were identified through searches of PUBMED, CINAHL and BIREME (1990 to 2009). In addition, hand searches of journals and citation tracking were performed. Study selection: Full-text studies involving any type of clinimetric tests of PBU measurement for the assessment of TrA activity were selected. Data extraction: Two independent reviewers selected the studies, extracted th...

2011-01-01

479

Measurement of electron-impact single-ionization cross sections of Ar"8"+  

International Nuclear Information System (INIS)

A crossed-electron-ion-beam experiment was used to measure the total ionization cross section for Ar"8"+ in the energy range from 50 to 600 eV. The present results are roughly in agreement with the previous measurements of Defrance et al. [Nucl. Instrum. Methods Phys. Res. B 23, 256 (1987)] above 450 eV. However, the present measurements show a significant contribution below the threshold for direct ionization. The present measurements agree with the distorted-wave calculations of Pindzola et al. [Phys. Rev. A 41, 1375 (1990)] when 3% of the incident ion beam is assumed to be in metastable states and excitation autoionization from metastable states is included.

480

Intuitionistic and interval-valued intutionistic fuzzy preference relations and their measures of similarity for the evaluation of agreement within a group  

British Library Electronic Table of Contents (United Kingdom)

Szmidt and Kacprzyk (Lecture Notes in Artificial Intelligence 3070:388?393, 2004a) introduced a similarity measure, which takes into account not only a pure distance between intuitionistic fuzzy sets but also examines if the compared values are more similar or more dissimilar to each other. By analyzing this similarity measure, we find it somewhat inconvenient in some cases, and thus we develop a new similarity measure between intuitionistic fuzzy sets. Then we apply the developed similarity measure for consensus analysis in group decision making based on intuitionistic fuzzy preference relations, and finally further extend it to the interval-valued intuitionistic fuzzy set theory.

2009-01-01

481

Impedance Noise Identification for State-of-Health Prognostics  

Energy Technology Data Exchange (ETDEWEB)

Impedance Noise Identification is an in-situ method of measuring battery impedance as a function of frequency using a random small signal noise excitation source. Through a series of auto- and cross-correlations and Fast Fourier Transforms, the battery complex impedance as a function of frequency can be determined. The results are similar to those measured under a lab-scale electrochemical impedance spectroscopy measurement. The lab-scale measurements have been shown to correlate well with resistance and power data that are typically used to ascertain the remaining life of a battery. To this end, the Impedance Noise Identification system is designed to acquire the same type of data as an on-board tool. A prototype system is now under development, and results are being compared to standardized measurement techniques such as electrochemical impedance spectroscopy. A brief description ...

2008-07-01

482

Fluid temperature measurement technique by using Raman scattering  

Energy Technology Data Exchange (ETDEWEB)

Temperature measurement technique by using Raman scattering was developed for the liquid water at temperature of 20 - 90 degree C and atmospheric pressure. Strong relationship between Raman scattering characteristics and liquid temperature change was observed. Various kinds of measurement techniques, such as Peak Intensity, Peak Wavelength, FWHM (Full Width at Half Maximum), PMCR ( Polymer Monomer Concentration RAte), TSIR (Temperature Sensitive Intensity Ratio), IDIA (Integral Difference Intensity Area) were tested. TSIR has the highest accuracy in mean error or 0.1 deg C and standard deviation of 0.1248 deg C. This report is one of the results in developing process of Raman temperature measurement technique. Next research step is to develop Raman temperature measurement technique at the high temperature and high pressure conditions in single or two phase flows. (author). 13 refs., 3 tabs., 38 figs.

1999-06-01

483

FFTF reactor-characterization program: gamma-ray measurements and shield characterization  

Science.gov (United States)

A series of experiments is to be made during the acceptance test program of the Fast Flux Test Facility (FFTF) to measure the gamma ray characteristics of the Fast Test Reactor (FTR) and to establish the performance characteristics of the reactor shield. These measurements are a part of the FFTF Reactor Characterization Program (RCP). Detailed plans have been developed for these experiments. During the initial phase of the Characteristics Program, which will be carried out in the In-Reactor Thimble (IRT), both active and passive measurement methods will be employed to obtain as much information concerning the gamma ray environment as is practical. More limited active gamma ray measurements also will be made in the Vibration Open Test Assembly (VOTA).

484

Development of ultrasonic measurement technique for the determination of vertical two-phase flow pattern  

Energy Technology Data Exchange (ETDEWEB)

In the present study, a new measurement technique which uses a ultrasonic transmission signals in order to determine the vertical two phase flow pattern even under high pressure condition. The ultrasonic measurement system developed in the present study not only provides the measurement functions required for the determination of vertical two phase flow pattern but also makes the real time determination possible. The developed ultrasonic measurement system accurately determined the various vertical two phase flow patterns such as bubbly, slug, churn, annular flow etc. In addition to the determination of flow patterns, qualitative informations for each flow pattern can be obtained, which include void fraction in bubbly flow, length of slug bubble and liquid tail characteristics in slug flow, and stable or transient condition of flow pattern, etc. 13 refs., 24 figs., 3 tabs. (Author)

2002-03-01

485

Developement of the method for realization of spectral irradiance scale featuring system of spectral comparisons  

Energy Technology Data Exchange (ETDEWEB)

Realization of the scale of spectral responsivity of the detectors in the Directorate of Measures and Precious Metals (DMDM) is based on silicon detectors traceable to LNE-INM. In order to realize the unit of spectral irradiance in the laboratory for photometry and radiometry of the Bureau of Measures and Precious Metals, the new method based on the calibration of the spectroradiometer by comparison with standard detector has been established. The development of the method included realization of the System of Spectral Comparisons (SSC), together with the detector spectral responsivity calibrations by means of a primary spectrophotometric system. The linearity testing and stray light analysis were preformed to characterize the spectroradiometer. Measurement of aperture diameter and calibration of transimpedance amplifier were part of the overall experiment. In this paper, the developed method is presented and ...

2010-10-15

486

Developement of the method for realization of spectral irradiance scale featuring system of spectral comparisons  

International Nuclear Information System (INIS)

Realization of the scale of spectral responsivity of the detectors in the Directorate of Measures and Precious Metals (DMDM) is based on silicon detectors traceable to LNE-INM. In order to realize the unit of spectral irradiance in the laboratory for photometry and radiometry of the Bureau of Measures and Precious Metals, the new method based on the calibration of the spectroradiometer by comparison with standard detector has been established. The development of the method included realization of the System of Spectral Comparisons (SSC), together with the detector spectral responsivity calibrations by means of a primary spectrophotometric system. The linearity testing and stray light analysis were preformed to characterize the spectroradiometer. Measurement of aperture diameter and calibration of transimpedance amplifier were part of the overall experiment. In this paper, the developed method is presented and ...

2010-10-01

487

Characteristics of lanthanides in pyrochemical systems observed by electrochemical and spectrophotometric measurements  

Energy Technology Data Exchange (ETDEWEB)

As research for the chemical properties of lanthanide molecules in the dry system, electrochemical and ultraviolet-visible optical measurements on the chloride molten salt system have been conducted at Research Reactor Institute, Kyoto University. The reduction behavior of Ln(III)-Ln(0) and Ln(II) are measured on La, Ce, Pr, Nd, Sm, Gd, Tb, Dy, Ho, and Yb by the cyclic voltammetry. The molar absorption coefficients of the f-f transition are measured by the measurement of ultraviolet-visible absorption spectra on Pr, Nd, Ho and Gd. From the comparison of the optical data between wet and dry systems, the characteristics of photon absorption are discussed in the molten salt. (H. Katsuta)

2001-12-01

488

Beam emittance measurements of ORNL negative ion sources  

Energy Technology Data Exchange (ETDEWEB)

The emittances of hydrogen and deuterium negative ion beams produced by volume ion sources have been measured in a transverse plane normal to the beam trajectory. The extraction voltage was varied from 10 to 40 kV, and the transverse magnetic field in the Penning discharges was varied from 0.1 to 0.2 T. Measurements were made on beams with current densities up to 60 mA/cm/sup 2/ at Oak Ridge National Laboratory with an emittance scanner originally developed at Los Alamos National Laboratory. The beam profile at the scanner can be used to improve the accuracy of the emittance measurements. Other factors affecting emittance measurements are discussed. This analysis may be applicable to other ion sources. 6 figs.

1989-01-01

489

Automated bead-positioning system for measuring impedances of R-F cavity modes  

Energy Technology Data Exchange (ETDEWEB)

We describe a fully automated bead puller system which uses stepping motors to position the bead, and an HP-8510 network analyzer to measure the resulting frequency shifts, both devices being under computer control. Longitudinal motion of the bead is used for measurement of cavity shunt impedance. In addition, azimuthal scans at fixed longitudinal position aid in determining the multipole character of higher-order modes. High sensitivity/accuracy is made possible by measuring phase shifts at the unperturbed resonant frequencies (rather than frequency shifts themselves), thereby permitting averaging factors of > 500 with only modest increases in data acquisition time. Sample measurements will be presented. A comprehensive analysis of the experimental results is presented in an accompanying paper.

1993-05-01

490

/sup 252/Cf-source-driven neutron noise measurements of subcriticality for a slab tank containing aqueous Pu-U nitrate  

Energy Technology Data Exchange (ETDEWEB)

In order to study nuclear criticality safety related to the development of fast breeder technology, /sup 252/Cf-source-driven neutron noise analysis measurements were performed with a Pu-U nitrate solution in a slab tank of various heights and thickness varying 11.43 cm to 19.05 cm. The results and conclusions of these experiments are (1) a capability to measure the subcriticality of a multiplying system of slab geometry to a k/sub eff/ as low as 0.7 was demonstrated, (2) calculated neutron multiplication factors agreed with those from the experiments within approx.0.02, and (3) the applicability of the method for plutonium solution systems was demonstrated. This paper describes measurements in which the height of the slab was varied for a fixed thickness and the thickness varied for a fixed height, which are the first applications of this measurement method to slab geometry.

1987-08-01

491

Magnetic field exposure assessment for adult residents of Maine who live near and far away from overhead transmission lines  

Science.gov (United States)

Sixty-Hz magnetic field exposures were measured for 45 adult residents of Maine. Thirty of the subjects resided near rights-of-way (ROWs) with either 345- and 115-kV transmission lines, or ROWs with only 115-kV transmission lines; fifteen resided far from any transmission lines. Personal exposure data for a single 24-hour period was acquired with the EMDEX. The EMDEX's event-marker button was used to partition exposures into Home and Away components. Also, three area measurements were taken for each subject during the personal exposure measurement period: (1) 24-hr fixed-site bedroom measurement with a second EMDEX; (2) Spot measurements in at least three rooms of every residence; and (3) Spot measurements outside each residence. Residence near transmission lines highly loaded during the measurement period was associated with ...

1992-01-01

492

Development of a Computer Program for the Integrated Control of the Fuel Homogeneity Measurement System  

Energy Technology Data Exchange (ETDEWEB)

The computer program is developed based on Visual C++, which is equipped with a user-friendly interface of the input/output(I/O) and a display function for the measuring conditions. This program consists of three parts which are the port communication, PLC(Programmable Logic Controller) and the MCA(Multi Channel Analyzer) control parts. The communication type between the CPU of the PLC module box and the computer is selected as be the Rs-232 asynchronous type and the thread method is adapted in the development of the first part of the program. The PLC-related program has been developed so that the data communication between the PLC CPU and the computer could be harmonized with the unique commands which have already been defined in the PLC. The measuring space and time intervals, the start and end ROI(region of interest) values, and the allowable error limitation are input at each measurement in this program. Finally the ...

2005-11-15

493

Transient-diffusion measurements of radon. Practical interpretation of measured data  

International Nuclear Information System (INIS)

The mathematical calculation to obtain a radon diffusion coefficient from measured radon transient-diffusion data is usually done by fitting a difference equation to the data. The difference equation is obtained through transformation of the time-dependent diffusion equation based on Fick's law. But, actual measured transient-diffusion data often have much scatter. Therefore just fitting over the whole range of the measured data through the method of least squares may not always be valid, because the method offers mathematical interpretation rather than a physical one. Instead, the actual radon diffusion coefficients must be otherwise obtainable from measured radon transient data. Taking this viewpoint, the present paper claims that about a 90% leveling-off time is often easily discernible regardless of the shape of the radon transient curve obtained from the measured data and it ...

2007-07-01

494

Physics of the {sup 252}Cf-source-driven noise analysis measurement  

Energy Technology Data Exchange (ETDEWEB)

The {sup 252}Cf-source-driven noise analysis method is a versatile measurements tool that has been applied to measurements for initial loading of reactors, quality assurance of reactor fuel elements, fuel processing facilities, fuel reprocessing facilities, fuel storage facilities, zero-power testing of reactors, verification of calculational methods, process monitoring, characterization of storage vaults, and nuclear weapons identification. This method`s broad range of application is due to the wide variety of time- and frequency domain signatures, each with unique properties, obtained from the measurement. The following parameters are obtained from this measurement: average detector count rates, detector multiplicities, detector autocorrelations, cross-correlation between detectors, detector autopower spectral densities, cross-power spectral densities between detectors, coherences, and ratios of ...

1997-02-01

495

On the determination of the dose-area product during X-ray examinations  

International Nuclear Information System (INIS)

Despite its great usefulness in the performance of the recording procedures prescribed by the X-Ray Ordinance the dose-area product is much less frequently measured for X-ray exposures than during fluorscopic examinations. The great multitude of measuring units, mainly on account of different scales of the measuring equipments themselves, is a cause of uncertainty in clinical routine and should be eliminated as far as the circumstances would permit. As the determination of the organ dose is relevant only in very few cases and does not necessarily require previous measurements of the dose-area product, these are of limited practical value in the assessment of individual radiation exposures during radiographic examinations. The measurements may, however, be very helpful in determinations of the radiation dose to the total population, if the future retrievability of the values obtained ...

496

Measuring characteristics on emissivity using infrared thermometer for RCCS  

International Nuclear Information System (INIS)

In VHTGR (Very High Temperature Gas-cooled Reactor), the radiation plays an important role in heat transfer through the cavity in RCCS (Reactor Cavity Cooling System). We performed the series of experiments to measure the emissivity using the infrared thermometer with wavelength range of 8#approx#14 #mu#m. As the first step, the transmittance of Zinc Selenide (ZnSe) window was measured to estimate the emissivity that can compensate the attenuation effect of window. The kind of gas with various concentrations in the cavity will be released during postulated accidents to the coolant type, so it is essential to estimate the effects of gas on the measurement of emissivity. In this manner we measured the emissivity with the air, the helium and the steam inside chamber. The results represent that the concentration of the air and the helium do not affect the emissivity significantly while the steam decreases ...

2004-12-01

497

Fuel spray evolution; Comparison of experiment and CFD simulation of nonevaporating spray  

Energy Technology Data Exchange (ETDEWEB)

Detailed spray characteristics were obtained for a small-capacity, pressure-swirl atomizer using an Aerometrics phase-Doppler particle analyzer. Measurements included drop size and velocity distributions, liquid volume fluxes, and air velocities at four axial locations, 25,50,75, and 100 mm, with complete radial traverses at each location. Drop size results were compared with measurements from a Malvern laser-diffraction instrument, and integrated liquid volume fluxes were compared with measured flow rates to estimate measurement uncertainties. Drop sizes measured by the two independent techniques and area-weighted-averaged over the radial traverses at each of the four axial stations varied on average by less than 4 percent. Integrated volume flux measurements by the phase-Doppler instrument at four axial stations differed from the nozzle flow rate by at most 19 ...

1989-01-01

498

Edge filter and fringe imaging for laser Doppler wind speed measurement  

Science.gov (United States)

Optical measurement of the Doppler shift of laser backscatter, using a near-IR, visible, or ultraviolet laser, is potentially more robust and field reliable than coherent, heterodyne measurement with an IR laser. The direct measurement of the displacement of Fabry-Perot interference fringes is possible, but entails expensive, technically challenging, imaging detectors. The 'edge technique' permits Doppler shift measurements with relatively simple detectors and detector electronics, and has been implemented with Fabry-Perot etalons and with atomic line filters. Simple analytical models of the fringe imaging and edge detection techniques are presented, permitting ready calculation of the potential performance of either, for various atmospheric conditions and for various lidar hardware configurations. The predictions of the analytical models are confirmed by computer models, which in turn allow more ...

1997-08-01

499

Double-Edge Molecular Measurement of Lidar Wind Profiles in the VALID Campaign  

Science.gov (United States)

We have developed a transportable container based direct detection Doppler lidar based on the double-edge molecular technique. The pulsed solid state system was built at the University of Geneva. It was used to make range resolved measurements of the atmospheric wind field as part of the VALID campaign at the Observatoire de Haute Provence in Provence, France in July 1999. Comparison of our lidar wind measurements, which were analyzed without knowledge of the results of rawinsonde measurements made under the supervision of ESA, show good agreement with these rawinsondes. These are the first Doppler lidar field measurements made with an eyesafe direct detection molecular-based system at 355 nm and serve as a demonstrator for future spaceborne direct detection wind systems such as the Atmospheric Dynamics mission. Winds are an important contributor to sea surface temperature ...

2000-01-01