The thermal modeling of electrochemical batteries is today an integral part of the design and validation operations of new products. The Li-ion pair allows to increase the power density of batteries but leads to higher heat fluxes during charging-output cycles. Thus, the thermal control has become more crucial and requires the use of modeling. SAFT and TSR companies are involved in this approach and use the ESACAP software. This paper presents this software which uses a nodal method for the modeling of the coupled thermal and electrical processes that take place inside elementary cells and batteries. (J.S.)
SPEOS takes advantage of a geological situation which apparently does not occur much in Switzerland. The SPEOS pilot installation, which was erected in 1982, is designed for the supply of heat for about 500 persons. In the course of 10 cycles, the possibilities and limits of the seasonal heat storage were displayed. It was demonstrated that large quantities of heat with temperatures of up to 75 C can be stored in an aquifer. The behaviour of such a storage can be predicted with sufficient accuracy with mathematical models. (author) 12 refs.
The LS electromagnetic band (1-4 GHz) is widely used both in domestic and industrial domains. Several studies suggested that the biological systems would exhibit a specific sensitivity to the 2.45 GHz microwaves (water resonance frequency). Potential human health hazards and especially a disruption of the cholinergic system have been reported, due to exposure to microwaves even at low power density. This work presents a multi-parametric study of freely moving rat where neuro-physiology was investigated during 70 hours using neurochemical (micro-dialysis technique), electrophysiological, behavioral (vigilance stages quantification) and thermo-physiological approaches. The rats were exposed 24 hours to a 2.45 GHz pulsed electromagnetic field at low power density. In this exposure conditions, no significant effect have been reported. (authors)
This final report for the Swiss Federal Office of Energy looks at the possibilities for improved waste water utilization in the Lavey-les-Bains thermal spa, Switzerland. According to the regulations in force, the temperature of the waste water rejected into the Rhone river shall not exceed 30 {sup o}C, what is currently not the case. Also the operational cost shall be reduced and the waste water quality improved. The installations are presented. From the two geothermal wells, mineral water comes out at an average flow rate of 940 l/min and a temperature of 63 {sup o}C. Actual waste water data are reported. The measured thermal water consumption data, including seasonal variations, are analysed by computerized simulation and measures to reduce the consumed volume by the optimization of internal procedures are evaluated. Measures to reduce the quantity of the rejected free chlorine are discussed. Several possible adaptations of the existing space heating, domestic water heating and ...
Due to its important hydroelectric power generation facilities (about 525 plants with a total power of 13,314 MW producing about 35.3 TWh annually) Switzerland plays an important role in the interconnected European power system. Large artificial storage lakes in the Swiss Alps can generate peak power during hours of highest demand: 9700 MW are available from accumulated energy and the total power of pumped-storage facilities amounts to 1700 MW. The latter allow refilling the reservoirs at periods of low power demand and generating power at periods of peak demand. In the case of favorable conditions, the yearly average power production could be increased by 6% and the production during the winter period (October to March) by 20% by the year 2020. However, looking forward to the year 2050, the annual production is expected to decrease by 3% despite a possible extension of hydropower. This decrease is due to the enforcement of the minimum residual water flow rates required by a new ...