WorldWideScience
1

Evaluation of the 1Shot Phantom dedicated to the mammography system using FCR  

International Nuclear Information System (INIS)

Currently daily quality control (QC) tests for mammography systems are generally evaluated by using visual analysis phantoms, which of course means subjective measurement. In our study, however, we evaluated a novel digital phantom, the 1Shot Phantom M plus (1Shot Phantom), together with automatic analysis software dedicated for mammography systems using Fuji computed radiography (FCR). The digital phantom enables objective evaluation by providing for actual physical measurement rather than subjective visual assessment. We measured contrast to noise ratio (CNR), image receptor homogeneity, missed tissue at chest wall side, modulation transfer function (MTF), and geometric distortion utilizing the 1Shot Phantom. We ...

2009-07-01

2

PowerPoint Presentation  

Wastenet

DEDICATED TO MAKING A DIFFERENCE ...DEDICATED TO MAKING A DIFFERENCE ...DEDICATED TO MAKING A DIFFERENCE

3

Monte Carlo simulation and scatter correction of the GE Advance PET scanner with SimSET and Geant4  

Energy Technology Data Exchange (ETDEWEB)

For Monte Carlo simulations to be used as an alternative solution to perform scatter correction, accurate modelling of the scanner as well as speed is paramount. General-purpose Monte Carlo packages (Geant4, EGS, MCNP) allow a detailed description of the scanner but are not efficient at simulating voxel-based geometries (patient images). On the other hand, dedicated codes (SimSET, PETSIM) will perform well for voxel-based objects but will be poor in their capacity of simulating complex geometries such as a PET scanner. The approach adopted in this work was to couple a dedicated code (SimSET) with a general-purpose package (Geant4) to have the efficiency of the former and the capabilities of the latter. The combined SimSET+Geant4 code (SimG4) was assessed on the GE Advance PET scanner and compared to the use of SimSET only. A better description of the resolution and sensitivity of the scanner and of the scatter fraction was obtained with SimG4. ...

2005-10-21

4

Artery phantoms for intravascular optical coherence tomography: healthy arteries  

UK PubMed Central (United Kingdom)

We present a method to make phantoms of coronary arteries for intravascular optical coherence tomography (IV-OCT). The phantoms provide a calibrated OCT response similar to the layered structure of...Full Text Available

5

Importance of anthropomorphic phantoms in nuclear medicine  

International Nuclear Information System (INIS)

... Brasileira de Biociencias Nucleares (SBBN), Recife, PE (Brazil) INIS-BR--9282

2010-10-27

6

Evaluation of tilted cone-beam CT orbits in the development of a dedicated hybrid mammotomograph  

UK PubMed Central (United Kingdom)

A compact dedicated 3D breast SPECT-CT (mammotomography) system is currently under development. In its initial prototype, the cone-beam CT sub-system is restricted to a fixed-tilt circular rotation...Full Text Available

2009-06-21

7

Phantom simulation device for scintillation cameras  

Energy Technology Data Exchange (ETDEWEB)

A phantom simulation imaging quality control device is described that effectively simulates one centimeter lesions, using steel ball bearings as gamma ray attenuators. The bearings are mounted in a synthetic resinous sheet in an orthogonal pattern. The phantom can provide uniformity, resolution, linearity, distortion and field size checks, all with a single exposure.

1981-08-25

8

Dose verification using a pelvic phantom in high dose rate (HDR) brachytherapy  

Energy Technology Data Exchange (ETDEWEB)

High dose rate (HDR) brachytherapy for treating a cervix carcinoma has become popular, because it eliminates many of the problems associated with conventional brachytherapy. In order to improve the clinical effectiveness with HDR brachytherapy, a dose calculation algorithm, optimization procedures, and image registrations need to be verified by comparing the dose distributions from a planning computer and those from a humanoid phantom. In this study, the humanoid phantom was fabricated in order to verify the absolute doses and the relative dose distributions. The measured doses from the humanoid phantom were then compared with the treatment planning system for the dose verification. The humanoid phantom needs to be designed such that the dose distributions can be quantitatively evaluated thermoluminescent dosimeter (TLD) chips with a dimension of 1/8 and film dosimetry with a spatial resolution of ...

2003-07-01

9

Exploration of exposure dose optimization for pelvic examination in direct digital radiography with a phantom  

International Nuclear Information System (INIS)

Objective: To investigate the relationship between exposure dose and image quality for a direct digital radiography system and to determine the optimum exposure parameters for pelvic examination. Methods: A contrast-detail phantom CDRAD2.0 was exposed to different doses and the IQF of phantom images were calculated. The optimum exposure parameters were determined by ANOVA and SNK analysis. The image of an anthropomorphic phantom taken with optimized exposure parameters was verified using CEC image criteria. Results: The IQF of the images of CDRAD2.0 phantom was significantly different for different doses, as the exposure dose was greater than 0.61 mGy. The IQFs have no difference for different dose groups. The image quality between this optimized exposure dose and conventional exposure dose not was significantly different. Conclusion: The image quality of direct digital radiography system is improved as ...

2005-10-01

10

Breast imaging with a dedicated PEM  

International Nuclear Information System (INIS)

During the last decade there was a growing interest on the application of Positron Emission Tomography, PET, techniques to Breast Imaging. More recently, preliminary results suggested the use of dedicated devices to Breast Imaging using the same technique, the so-called Positron Emission Mammography cameras, PEM. In this article we review the arguments leading to a dedicated instrument. Based on these arguments we describe the concept of a PEM camera under development within the Crystal Clear Collaboration and the first results of its expected performance in terms of sensitivity and position resolution.

2004-07-11

11

Phase-space analysis of interacting phantom cosmology  

CERN Document Server

We perform a detailed phase-space analysis of various phantom cosmological models, where the dark energy sector interacts with the dark matter one. We examine whether there exist late-time scaling attractors, corresponding to an accelerating universe and possessing dark energy and dark matter densities of the same order. We find that all the examined models, although accepting stable late-time accelerated solutions, cannot alleviate the coincidence problem, unless one imposes a form of fine-tuning in the model parameters. It seems that interacting phantom cosmology cannot fulfill the basic requirement that led to its construction.

2008-01-01

12

Phantom dark energy with varying-mass dark matter particles: acceleration and cosmic coincidence problem  

CERN Document Server

We investigate several varying-mass dark-matter particle models in the framework of phantom cosmology. We examine whether there exist late-time cosmological solutions, corresponding to an accelerating universe and possessing dark energy and dark matter densities of the same order. Imposing exponential or power-law potentials and exponential or power-law mass dependence, we conclude that the coincidence problem cannot be solved or even alleviated. Thus, if dark energy is attributed to the phantom paradigm, varying-mass dark matter models cannot fulfill the basic requirement that led to their construction.

2009-01-01

13

Technical report templates  

Wastenet

Performance testing and ...Performance testing and commissioning In either an Authority-owned or a dedicated MRF, the Contracting Authority should ...Performance testing is done to demonstrate that the contractor is able to meet the guarantees given

14

Networking of Palliative Care at the Corporate Level  

UK PubMed Central (United Kingdom)

This article is a story of networking of palliative care at the corporate level. This gives an insight that if you have will and dedication then you can imagine and make it true that networking can...Full Text Available

2011-01-01

15

NIMH Expands Public Health Education Effort to Reach Latino Men...  

Science.gov (United States)

health research agency, NIMH is dedicated to reducing the burden of mental and behavioral disorders through research on mind, brain, and behavior. As part of that mission, NIMH...

2011-09-24

16

Does the SBCT Intelligence Structure Need a Dedicated ACE ...  

Science.gov (United States)

... for the 313th Military Intelligence Battalion, 82nd Airborne Division, http://www ... and Equipment (TOE) for an airborne/air assault division ACE is used ...

2004-05-26

17

Morphine versus Mexiletine for Treatment of Postamputation Pain  

UK PubMed Central (United Kingdom)

BackgroundStump and phantom pains are debilitating sequelae of amputations that are often resistant to treatment. The efficacy of pharmacologic therapies, including...Full Text Available

2008-08-01

18

Comparing dose calculation algorithms for an orthovoltage beam in a bone phantom  

International Nuclear Information System (INIS)

The aim of this work was to compare dose calculation algorithm results at orthovoltage energies for a phantom composed of a bone slab in water. The calculation methods investigated were: no correction, ETAR, Batho, convolution/superposition and Monte Carlo. All algorithms calculated depth dose curves in a water phantom within 4% of experiment. However in the bone phantom, differences of over 40% between the No Correction / ETAR / Batho / Convolution and Monte Carlo results in the 1 cm thick bone slab were observed. These differences are predominantly because the algorithms do not account for the differing atomic number of the bone compared to water The increased dose to bone and the tissue adjacent to the bone interface should be considered when treating with orthovoltage photons. Copyright (1998) Australasian Physical and Engineering Sciences in Medicine

1998-09-01

19

Chronic Pain Associated with Upper-Limb Loss  

UK PubMed Central (United Kingdom)

ObjectiveTo describe the prevalence, intensity, and functional impact of the following types of pain associated with upper-limb loss: phantom limb, residual limb,...Full Text Available

2009-09-01

20

Gas-cooled fast reactor safety - and overview and status of the U.S. program  

International Nuclear Information System (INIS)

In the revised GCFR Safety Program Plan a quantitative risk limit line has been adopted to establish requirements for the safety related functions and systems. The risk limit line is derived from an interpretation of NRC established licensing requirements, including those for LMFBR's. Multiple barriers to the progression of accident sequences are defined in the form of six Lines of Protection (LOPs). LOPs-1 to 3 are dedicated to accident prevention and represent the normal operating systems, the dedicated safety systems and the inherent design features, respectively. LOPs-4 to 6 are dedicated to the mitigation of core melt accident consequences and include in-vessel accident containment, secondary containment integrity and radiological attenuation, respectively. Cumulative frequency limits and consequence limits are established for each LOP. Design features associated with each LOP are described and the results of ...

1981-01-01

21

Pulsed Radiofrequency Ablation for Residual and Phantom Limb Pain: A Case Series  

British Library Electronic Table of Contents (United Kingdom)

Abstract Residual limb pain (RLP) and phantom limb pain (PLP) can be debilitating and can prevent functional gains following amputation. High correlations have been reported between RLP and the stump neuromas following amputation. Many treatment methods including physical therapy, medications, and interventions, have been used with limited success. Pulsed radiofrequency ablation (PRFA) has shown promise in treating neuropathic pain because of the inhibition of evoked synaptic activity. We present 4 amputees who were treated with PRFA after failing conservative management for their RLP and PLP. All 4 patients underwent PRFA and demonstrated at least 80% relief of RLP for over 6 months. One patient reported a complete resolution of phantom sensation while another patient had significantly de...

2010-01-01

22

Monte Carlo simulations incorporating Mie calculations of light transport in tissue phantoms: Examination of photon sampling volumes for endoscopically compatible fiber optic probes  

Energy Technology Data Exchange (ETDEWEB)

Details of the interaction of photons with tissue phantoms are elucidated using Monte Carlo simulations. In particular, photon sampling volumes and photon pathlengths are determined for a variety of scattering and absorption parameters. The Monte Carlo simulations are specifically designed to model light delivery and collection geometries relevant to clinical applications of optical biopsy techniques. The Monte Carlo simulations assume that light is delivered and collected by two, nearly-adjacent optical fibers and take into account the numerical aperture of the fibers as well as reflectance and refraction at interfaces between different media. To determine the validity of the Monte Carlo simulations for modeling the interactions between the photons and the tissue phantom in these geometries, the simulations were compared to measurements of aqueous suspensions of polystyrene microspheres in the wavelength range 450-750 nm.

1996-04-01

23

Estimated fetal radiation dose from multislice CT studies  

International Nuclear Information System (INIS)

It is often necessary to estimate the dose of radiation to a fetus from a series of CT scans. To assist in making this process easier and more accurate, we measured fetal doses in an adult anthropomorphic phantom for four CT scanners: Picker 1200, Siemens DRH, GE 9800, and GE 8800. Measurements were made at four kilovoltages (100, 120, 130, and 140 kVp), for 2-, 5-, 8-, and 10-mm thicknesses, for two scanning angles (360 degrees and 398 degrees) and for two patient orientations (prone and supine). The fetal-dose estimates are based on the CT dose index measured by using a pencil ionization chamber at the center position of a 16-cm-diameter cylindrical phantom. Comparison with data from other investigators shows reasonable agreement when phantom differences, X-ray tube output, and equipment calibration are considered.

24

Dose enhancement in bone in electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

This study investigated dose to bone tissue in electron beam therapy. Measurements were made using films and thermoluminescent dosimeters in a polystyrene phantom containing bone inhomogeneity for 15-MeV, 12-MeV, and 9-MeV electron beams. An increase in dose of approximately 18%, 12%, and 11%, for the three electron energies respectively, relative to the dose in polystyrene, was found for bone material having an electron density (relative to water) of 1.73. Measurements were also made using films for 15- and 9-Mev electrons in a phantom with a mandibular bone and teeth. A dose enhancement in bone of approximately 10% and 7%, respectively, for the two energies was found in the phantom where the electron density of bone was about 1.60. These results suggest that injury to bone is possible in those clinical situations where high doses of electrons are used for therapy.

1984-05-01

25

Dose enhancement in bone in electron beam therapy  

International Nuclear Information System (INIS)

This study investigated dose to bone tissue in electron beam therapy. Measurements were made using films and thermoluminescent dosimeters in a polystyrene phantom containing bone inhomogeneity for 15-MeV, 12-MeV, and 9-MeV electron beams. An increase in dose of approximately 18%, 12%, and 11%, for the three electron energies respectively, relative to the dose in polystyrene, was found for bone material having an electron density (relative to water) of 1.73. Measurements were also made using films for 15- and 9-Mev electrons in a phantom with a mandibular bone and teeth. A dose enhancement in bone of approximately 10% and 7%, respectively, for the two energies was found in the phantom where the electron density of bone was about 1.60. These results suggest that injury to bone is possible in those clinical situations where high doses of electrons are used for therapy.

26

Use of solid state nuclear track detectors for radon concentration measurements indoors  

International Nuclear Information System (INIS)

An indoor radioactive survey is being conducted in an Italian district. Preliminary results identified a zone with significant radioactive levels, in which a new specific survey has been planned. In this paper attention is dedicated mainly to radon measurement technique and results.

27

Position-sensitive proportional counter for space-based X-ray imaging studies  

International Nuclear Information System (INIS)

ASTROSAT, India's first dedicated astronomy satellite is slated for launch in 2007. The primary science objective of ASTROSAT is to explore the Universe using broad-band instruments covering optical, UV, soft X-ray and hard X-ray studies

2005-03-01

28

Numerical optimization of spherical variable-line-spacing grating X-ray spectrometers  

UK PubMed Central (United Kingdom)

Operation of an X-ray spectrometer based on a spherical variable-line-spacing (VLS) grating is analyzed using dedicated ray-tracing software allowing fast optimization of the grating parameters and...Full Text Available

2011-03-01

29

Feynman lectures on physics, quantum mechanics; Le cours de physique de Feynman mecanique quantique  

Energy Technology Data Exchange (ETDEWEB)

This course is based upon lectures in physics given by Professor Feynman at the California institute of technology during 1961 and 1962. This volume is dedicated to quantum physics, semiconductors, symmetry and advanced principles of physics.

2000-07-01

30

11-NIF Dedication: Dianne Feinstein  

ScienceCinema

...march and my hope is that global warming because i believe it is real and i believe we have ...global warming ...system of energy which does not produce the global warming guess they should be here ? ...

31

Technical note: A physical phantom for assessment of accuracy of deformable alignment algorithms  

International Nuclear Information System (INIS)

The purpose of this study was to investigate the feasibility of a simple deformable phantom as a QA tool for testing and validation of deformable image registration algorithms. A diagnostic thoracic imaging phantom with a deformable foam insert was used in this study. Small plastic markers were distributed through the foam to create a lattice with a measurable deformation as the ground truth data for all comparisons. The foam was compressed in the superior-inferior direction using a one-dimensional drive stage pushing a flat 'diaphragm' to create deformations similar to those from inhale and exhale states. Images were acquired at different compressions of the foam and the location of every marker was manually identified on each image volume to establish a known deformation field with a known accuracy. The markers were removed digitally from corresponding images prior to registration. Different image registration algorithms were tested using ...

2007-07-01

32

PHARMACOLOGICAL TREATMENTS FOR TINNITUS: NEW AND OLD  

UK PubMed Central (United Kingdom)

Subjective tinnitus, the phantom ringing or buzzing sensation that occurs in the absence of sound, affects 12–14% of adults; in some cases the tinnitus is so severe or disabling that...Full Text Available

2009-01-01

33

Monte Carlo modeling of 60Co HDR brachytherapy source in water and in different solid water phantom materials  

UK PubMed Central (United Kingdom)

The reference medium for brachytherapy dose measurements is water. Accuracy of dose measurements of brachytherapy sources is critically dependent on precise measurement of the source–detector...Full Text Available

2010-01-01

34

Intelligent Motion and Interaction Within Virtual Environments  

Science.gov (United States)

Typical aircraft types supported include F4-Phantom, Tornado, MiG-29 ...... attempt to develop a theoretical explanation for learning phenomena [16]. ..... perspective, a primary reason for this is that an exponential curve approximates ...

35

Computed radiography in X-ray examination of stomach. Evaluation by phantom experiments and clinical studies  

Energy Technology Data Exchange (ETDEWEB)

The usefulness and clinical applicability of computed radiography(FCR) in X-ray examination of the stomach were evaluated in comparison with film-screen (FS) radiography by both phantom experiments and clinical studies. Receiver operating characteristic (ROC) curve analysis consisting of 25 normal and 25 artificially created simulated lesions on an orginally created Styrofoam phantom showed no difference in lesion detectability between FCR and FS radiography. Both were also equal in evaluation of the internal structure and margin of the 25 lesions by visual ranking. ROC curve analysis of clinical cases was performed in 30 cases, 20 normal and 10 abnormal, while evaluation by visual ranking was performed on 18 lesions. There was no significant difference between FCR and FS radiography either with ROC curve analysis or visual ranking, although the variations were somewhat greater in the clinical cases than in the phantom ...

1995-08-01

36

Computed radiography in X-ray examination of stomach. Evaluation by phantom experiments and clinical studies  

International Nuclear Information System (INIS)

The usefulness and clinical applicability of computed radiography(FCR) in X-ray examination of the stomach were evaluated in comparison with film-screen (FS) radiography by both phantom experiments and clinical studies. Receiver operating characteristic (ROC) curve analysis consisting of 25 normal and 25 artificially created simulated lesions on an orginally created Styrofoam phantom showed no difference in lesion detectability between FCR and FS radiography. Both were also equal in evaluation of the internal structure and margin of the 25 lesions by visual ranking. ROC curve analysis of clinical cases was performed in 30 cases, 20 normal and 10 abnormal, while evaluation by visual ranking was performed on 18 lesions. There was no significant difference between FCR and FS radiography either with ROC curve analysis or visual ranking, although the variations were somewhat greater in the clinical cases than in the phantom ...

1995-01-01

37

A convolution/superposition method using primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance: comparison of calculated and measured 10-MV X-ray doses in thorax-like phantoms  

British Library Electronic Table of Contents (United Kingdom)

We performed experimental studies on the convolution/superposition method reported in the former companion paper (Iwasaki in Radiol Phys Technol 4, 2011) using 10-MV X-ray beams from open-jaw-collimated fields. The method uses primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. We made a comparison of calculations and measurements in water phantoms and thorax-like phantoms with respect to percentage depth dose curves, tissue???phantom ratio curves, and dose profiles. We made the dose calculation by taking into account the beam-hardening effect with depth and the off-axis radiation-softening effect. We found that the method could be used, in general, for performing accurate dose calculations.

2011-01-01

38

Development of a geometrically accurate imaging protocol at 3 Tesla MRI for stereotactic radiosurgery treatment planning  

International Nuclear Information System (INIS)

The purpose of this study is to develop a geometrically accurate imaging protocol at 3 T magnetic resonance imaging (MRI) for stereotactic radiosurgery (SRS) treatment planning. In order to achieve this purpose, a methodology is developed to investigate the geometric accuracy and stability of 3 T MRI for SRS in phantom and patient evaluations. Forty patients were enrolled on a prospective clinical trial. After frame placement prior to SRS, each patient underwent 3 T MRI after 1.5 T MRI and CT. MR imaging protocols included a T1-weighted gradient echo sequence and a T2-weighted spin echo sequence. Phantom imaging was performed on 3 T prior to patient imaging using the same set-up and imaging protocols. Geometric accuracy in patients and phantoms yielded comparable results for external fiducial reference deviations and internal landmarks between 3 T and 1.5 T MRI (mean ?0.6 mm; standard deviation ?0.3 mm). Mean stereotactic ...

2010-11-21

39

Study of spatial resolution in three-dimensional rotational angiography  

International Nuclear Information System (INIS)

In interventional radiology (IVR) of cerebral aneurysms, it is important to understand the form and physical relationships between the cerebral aneurysm and the surrounding vessels. However, because the vessels in the head area are highly complex, it can be difficult to comprehend the structure using conventional angiography. Therefore, three-dimensional rotational angiography (3D-RA) has been used in recent years. This article discusses studies of the spatial resolution of 3D-RA. We reconstructed 3D-RA of an acrylic slit phantom (slit widths: 0.5, 0.75, 1.0, 1.5 mm) and examined spatial resolution by visual evaluation and profile curves. When the slit phantom was arranged to avoid the effect of beam hardening, the spatial resolution of 3D-RA was found to be as high as 0.75 mm. When the slit phantom was placed orthogonal to the rotational axis of the C-arm, the spatial resolution of 3D-RA was decreased because of the cone ...

2006-03-01

40

Phantom and animal imaging studies using PLS synchrotron X-rays  

CERN Document Server

Ultra-high resolution radiographs can be obtained using synchrotron X-rays. A collaboration team consisting of K-JIST, POSTECH and YUMC has recently commissioned a new beamline (5C1) at Pohang Light Source (PLS) in Korea for medical applications using phase contrast radiology. Relatively simple image acquisition systems were set up on 5C1 beamline, and imaging studies were performed for resolution test patterns, mammographic phantom, and animals. Resolution test patterns and mammographic phantom images showed much better image resolution and quality with the 5C1 imaging system than the mammography system. Both fish and mouse images with 5C1 imaging system also showed much better image resolution with great details of organs and anatomy compared to those obtained with a conventional mammography system. A simple and inexpensive ultra-high resolution imaging system on 5C1 beamline was successfully implemented. The authors were able to acquire ...

2001-01-01

41

Neutron capture therapy beam on the LVR-15 reactor  

Energy Technology Data Exchange (ETDEWEB)

Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The distribution of thermal neutrons in the human head phantom was mapped with a small semiconductor detector (Si[sup ...

1992-01-01

42

Neutron capture therapy beam on the LVR-15 reactor  

International Nuclear Information System (INIS)

Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The distribution of thermal neutrons in the human head phantom was mapped with a small semiconductor detector (Si"6Li). ...

1991-10-01

43

Monte Carlo code comparisons for the calculation of absorbed dose per unit fluence in slab phantoms for electron energies from 50 keV to 10 MeV  

International Nuclear Information System (INIS)

The MCNPE-BO and MCNP4 Monte Carlo electron-photon codes were used to calculate the dose equivalent per unit fluence at various depths in tissue-equivalent slab phantoms for broad parallel beams of monoenergetic electrons with energies from 50 keV to 10 MeV. The study was carried out in the framework of the activities of a ICRP/ICRU Joint Task Group with the support of EURADOS WG4 (Numerical Dosimetry). Some preliminary results and comparisons as well as a general discussion on the performances of the codes are presented, demonstrating quite a satisfactory agreement among the results obtained using the two codes and those of other authors. (author).

44

Dosimetric evaluation of multi-pattern spatially fractionated radiation therapy using a multi-leaf collimator and collapsed cone convolution superposition dose calculation algorithm  

British Library Electronic Table of Contents (United Kingdom)

Purpose: In this paper, we present an alternative to the originally proposed technique for the delivery of spatially fractionated radiation therapy (GRID) using multi-leaf collimator (MLC) shaped fields. We employ the MLC to deliver various pattern GRID treatments to large solid tumors and dosimetrically characterize the GRID fields. Methods and materials: The GRID fields were created with different open to blocked area ratios and with variable separation between the openings using a MLC. GRID designs were introduced into the Pinnacle3 treatment planning system, and the dose was calculated in a water phantom. Ionization chamber and film measurements using both Kodak EDR2 and Gafchromic EBT film were performed in a SolidWater phantom to determine the relative output of each GRID design as w...

2009-01-01

45

Comparison of fluid-dynamic modeling of flow with velocity-encoded MR imaging  

International Nuclear Information System (INIS)

This paper develops a fluid dynamic model using finite difference methods characterizing flow in phantoms simulating in vivo conditions and to compare those results with velocity encoded MR images. The phantom consisted of 1-inch (2.5-cm) tubing with semicircular insert and fluid with viscosity, T1, and T2 comparable to blood. Numeric solutions to Navier-Stokes equations for this system were obtained using finite difference methods, with velocity input function of zero at walls and parabolic at both ends. In resulting color raster (CR) images, color temperature represented velocity value. In velocity-encoded MR images acquired under the same flow conditions, phase is proportional to average velocity during application of flow-encoding gradients. Because these gradients are applied along one direction per acquisition, magnitude and direction of velocity are obtained.

1990-11-25

46

Wolsung-1 nuclear power plant  

International Nuclear Information System (INIS)

The Wolsung-1 CANDU 600 MWe plant is now in operation. This paper provides an update on the design, construction and commissioning progress reported at last year's conference. The accomplishments of the past year are highlighted with emphasis on how the station has been commissioned in preparation for commercial service and on the skills that were dedicated to the completion of the project. The paper also deals with some of the features of the CANDU 600 MWe Nuclear Power Plant that make it viable for export.

1977-06-05

47

UIC HIGHSPEED 2008 - the leading world event dedicated to high speed rail  

Energy Technology Data Exchange (ETDEWEB)

The UIC High Speed Department's flagship event is the World Congress on High Speed Rail held approximately every three years. This year's congress will take place in Amsterdam from 17 to 19 March 2008. (orig.)

2008-07-01

48

The polarized electron gun for the SLC  

International Nuclear Information System (INIS)

A new polarized electron gun for use on the SLC at SLAC has been built and tested. It is a diode gun with a laser driven GaAs photocathode. It is designed to provide short (2ns) pulses of 10 A at 160 kV at 120 Hz. The design features of the gun and results from a testing program on a new and dedicated beam line are presented. Early results from operation on the SLC will also be shown.

1992-03-24

49

Tehachapi solar thermal system first annual report  

Energy Technology Data Exchange (ETDEWEB)

The staff of the Southwest Technology Development Institute (SWTDI), in conjunction with the staff of Industrial Solar Technology (IST), have analyzed the performance, operation, and maintenance of a large solar process heat system in use at the 5,000 inmate California Correctional Institution (CCI) in Tehachapi, CA. This report summarizes the key design features of the solar plant, its construction and maintenance histories through the end of 1991, and the performance data collected at the plant by a dedicated on-site data acquisition system (DAS).

1993-05-01

50

Power for electric cars. Energie fuer Elektroautos; Batterien und Brennstoffzellen  

Energy Technology Data Exchange (ETDEWEB)

This book reports on the state of the art of electric cars. The application of batteries and fuel cells is focussed on. The authors report on the developmental state of electric and solar vehicles. The second part of the book is dedicated to novel battery systems and feasible applications for fuel cells. Each of the 11 papers was abstracted. (HW)

1993-01-01

51

High-explosives test facility  

Energy Technology Data Exchange (ETDEWEB)

This report describes a high explosives test facility that makes efficient use of equipment and combines utility, convenience, and safety in a modest amount of space. It is a dedicated facility for exploratory development efforts that previously were conducted in a single room having very limited capabilities. Two explosives testing areas are now available and several projects are supported concurrently.

1982-08-01

52

Dimensional metrology and positioning operations: basics for a spatial layout analysis of measurement systems  

CERN Document Server

Dimensional metrology and positioning operations are used in many fields of particle accelerator projects. This lecture gives the basic tools to designers in the field of measure by analysing the spatial layout of measurement systems since it is central to dimensional metrology as well as positioning operations. In a second part, a case study dedicated to a synchrotron storage ring is proposed from the detection of the magnetic centre of quadrupoles to the orbit definition of the ring.

2010-01-01

53

DIPAC 2005 7. European workshop on beam diagnostics and instrumentation for particle accelerators  

Energy Technology Data Exchange (ETDEWEB)

Accelerators can not be improved without the development of adequate beam instruments and diagnostic tools. This year this statement is particularly right: a lot of contributions are dedicated to beam monitoring and to the design of new beam monitors based on original technologies. This document gathers about 100 contributions.

2005-07-01

54

Coal uses and upgrading processes  

Energy Technology Data Exchange (ETDEWEB)

The paper discusses the status of coal as a raw material and energy source. After referring to coal preparation and the costs it involves the author deals with coal/liquid suspensions and their fueling uses. Access is given to different aspects concerning the use of coal for electric power and heat generation. They include pollution abatement measures, economic analyses and fuel engineering in the case of coal. Further sections are dedicated to upgrading procedures such as the gasification, liquefaction and coking of coal. A bibliography informs the reader about further publications available on the subject. (HAG).

1986-04-01

55

Classical fracture mechanics methods  

International Nuclear Information System (INIS)

Comprehensive Structural Integrity is a reference work which covers all activities involved in the assurance of structural integrity. It provides engineers and scientists with an unparalleled depth of knowledge in the disciplines involved. The new online Volume 11 is dedicated to the mechanical characteristics of materials. This paper contains the chapter 11.02 of this volume and is structured as follows: Test techniques; Analysis; Fracture behavior; Fracture toughness tests for nonmetals.

56

ADS as Information Management Service in an M-Learning Environment  

CERN Document Server

Leveraging the potential power of even small handheld devices able to communicate wirelessly requires dedicated support. In particular, collaborative applications need sophisticated assistance in terms of querying and exchanging different kinds of data. Using a concrete example from the domain of mobile learning, the general need for information dissemination is motivated. Subsequently, and driven by infrastructural conditions, realization strategies of an appropriate middleware service are discussed.

2007-01-01

57

The different structural scales of the breast and their impact on time-of-flight and diffraction tomography  

Energy Technology Data Exchange (ETDEWEB)

Ultrasound tomography is an attractive imaging method for the detection of breast cancer. The complex anatomy of the breast with its different spatial scales and material property contrasts make accurate reconstructions very challenging. This paper proposes a hybrid approach whereby Travel-of-Flight and Diffraction Tomography are combined together to achieve high-resolution and high-accuracy sound-speed reconstructions. The method is validated with several numerical phantoms.

2010-01-01

58

Introducing DeBRa: a detailed breast model for radiological studies  

Energy Technology Data Exchange (ETDEWEB)

Currently, x-ray mammography is the method of choice in breast cancer screening programmes. As the mammography technology moves from 2D imaging modalities to 3D, conventional computational phantoms do not have sufficient detail to support the studies of these advanced imaging systems. Studies of these 3D imaging systems call for a realistic and sophisticated computational model of the breast. DeBRa (Detailed Breast model for Radiological studies) is the most advanced, detailed, 3D computational model of the breast developed recently for breast imaging studies. A DeBRa phantom can be constructed to model a compressed breast, as in film/screen, digital mammography and digital breast tomosynthesis studies, or a non-compressed breast as in positron emission mammography and breast CT studies. Both the cranial-caudal and mediolateral oblique views can be modelled. The anatomical details inside the phantom include the lactiferous ...

2009-07-21

59

IMRT verification by three-dimensional dose reconstruction from portal beam measurements  

International Nuclear Information System (INIS)

A method of reconstructing three-dimensional, in vivo dose distributions delivered by intensity-modulated radiotherapy (IMRT) is presented. A proof-of-principle experiment is described where an inverse-planned IMRT treatment is delivered to an anthropomorphic phantom. The exact position of the phantom at the time of treatment is measured by acquiring megavoltage CT data with the treatment beam and a research prototype, flat-panel, electronic portal imaging device. Immediately following CT imaging, the planned IMRT beams are delivered using the multiple-static field technique. The delivered fluence is sampled using the same detector as for the CT data. The signal measured by the portal imaging device is converted to primary fluence using an iterative phantom-scatter estimation technique. This primary fluence is back-projected through the previously acquired megavoltage CT model of the phantom, with ...

2002-08-01

60

Further means for reducing radiation dose during exposure of the pelvis in infants  

International Nuclear Information System (INIS)

A simple dose-saving procedure for the diagnosis of congenital hip dysplasia employing a diaphragm in nearfocus position is presented. Doses to the skin and the gonads were measured with a phantom for the new and other techniques. With optimal techniques the skin dose is smaller than 2 mR and the gonadal doses lie around 0.1 mR for both male and female patients. An estimate of the dose burden from undesired radiation is appended. (orig.).

61

Evaluation of calcification in pulmonary nodules using bone images obtained with single exposure energy subtraction  

Energy Technology Data Exchange (ETDEWEB)

Bone images obtained by single exposure dual energy subtraction with computed radiography, a new image processing method, were evaluated for the detectability of calcification in lung nodules in both phantom and clinical studies. In the phantom study, five simulated nodules containing known and uniformly distributed amounts of calcium hydroxide were placed in a human chest phantom and images were obtained the following five techniques: (1) conventional radiography (CXR), (2) low kV conventional radiography (Low), (3) Fuji computed radiography (FCR), (4) bone images with conventional singles exposure energy subtraction (ES) and (5) bone image with fine single exposure energy subtraction (FES). The detectability of calcification in the simulated nodules was evaluated by six radiologists using ROC analysis and two-way analysis of variance. In the clinical study, images of 42 lung nodules (21 calcified lung nodules and 21 ...

1995-08-01

62

Evaluation of calcification in pulmonary nodules using bone images obtained with single exposure energy subtraction  

International Nuclear Information System (INIS)

Bone images obtained by single exposure dual energy subtraction with computed radiography, a new image processing method, were evaluated for the detectability of calcification in lung nodules in both phantom and clinical studies. In the phantom study, five simulated nodules containing known and uniformly distributed amounts of calcium hydroxide were placed in a human chest phantom and images were obtained the following five techniques: 1) conventional radiography (CXR), 2) low kV conventional radiography (Low), 3) Fuji computed radiography (FCR), 4) bone images with conventional singles exposure energy subtraction (ES) and 5) bone image with fine single exposure energy subtraction (FES). The detectability of calcification in the simulated nodules was evaluated by six radiologists using ROC analysis and two-way analysis of variance. In the clinical study, images of 42 lung nodules (21 calcified lung nodules and 21 ...

1995-01-01

63

A novel method to characterize the MTF in 3D for computed mammotomography  

Science.gov (United States)

A novel phantom has been developed to measure the modulation transfer function (MTF) in 3D for x-ray computed tomography. The phantom consists of three tungsten wires, positioned nearly orthogonal to each other. Simultaneous measurements of the MTF are taken at various locations along the three orthogonal reconstructed planes. Our computed mammotomography (CmT) system uses a Varian Paxscan 2520 digital x-ray detector which can be positioned anywhere in ~2pi steradian band and can have arbitrary trajectories. With a half-cone beam geometry and with the phantom positioned near the center of rotation, projection images are acquired over 360 degrees. Various 3D orbits are evaluated including vertical axis of rotation and saddle. Reconstructions were performed using an iterative ordered-subsets transmission algorithm on rebinned projection images, using various numbers of iterations. Rotation of reconstructed slices isolated ...

2006-03-01

64

A comparison of cathode ray tube (CRT) and computed radiography (CR) diagnosis in mammography  

International Nuclear Information System (INIS)

Quantitative evaluation of CRT and CR observations in indentification of malignancy using phantom and clinical data. A breast phantom and a total of 40 patients were imaged by Fuji computed radiography (FCR). The images were interpreted twice by six radiologists both on CR film (2510 x 2000 pixels x 10 bits, 0.1 mm spatial resolution) and on a CRT monitor (1568 x 1152 pixels x 10 bits, 0.1 mm pixel size with double expansion) with image processing parameters of a toutine (RN 1.0, RE 0.2), for a calcification (RN 9.0, RE 4.0) and for a mass (RN 7.0, RE 2.0). The forty clinical cases included breast diseases with calcifications, masses, and normal breasts. Two-tailed t-test was performed to analyze interpretation of simulated microcalcifications and masses in the phantom. The receiver operating characteristic (ROC) analysis was performed to evaluate clinical cases. In all interpretation studies using both breast ...

1999-11-01

65

Prediction of transmitted portal dose for in-vivo dosimetry by a superposition-convolution planning system  

International Nuclear Information System (INIS)

Full text: Verification of the dose delivered to a patient during radiotherapy is an important quality assurance procedure, however this is rarely performed due to the extra time involved. Electronic portal images (EPIs) are currently acquired at many centres during radiotherapy treatment for positioning verification. These could be utilised for dose verification provided 1) an accurate prediction of the dose transmitted through the patient to the EPID can be produced for the patients' radiotherapy beams, and, 2) the EPID image can be converted to an accurate measured dose. Ideally, the radiotherapy planning system (RTPS) would be used to produce the predicted dose as part of the planning procedure. The aim of this project is to investigate whether the convolution-superposition model of the Pinnacle RTPS can accurately calculate dose transmitted through a patient and deposited in a phantom at a large source to surface distance. The dose transmitted through a ...

2004-12-01

66

Muon trigger, flavour tagging and physics performance of the LHCb experiment; Trigger a muons, etiquetage de la saveur et performances physiques de l'experience LHCb  

Energy Technology Data Exchange (ETDEWEB)

The LHCb experiment that is being settled in CERN is dedicated to the study of CP violation and rare decays in the field of beauty hadrons. The phenomenological background necessary to an adequate understanding of the physics of flavor is presented in the first chapter, it is shown how the flavordynamics can open the way to new physics. The second chapter is dedicated to a brief presentation of the LHCb detector. Two aspects of the design of the muon trigger are more detailed: the radiation resistance of the opto-electronic transmitters and the simulated performances of the trigger. The third chapter reviews the tasks linked to the tagging of the savors of B mesons which will be an important step in all the experiments made at LHCb. The recent progress in heavy savor physics as well as the expected contribution of LHCb in this field are presented in the fourth chapter, especially the search for new physics in penguin diagrams b {yields} s.

2007-10-15

67

Expert overseer for mass spectrometer system  

Energy Technology Data Exchange (ETDEWEB)

This patent describes an expert overseer for the operation and real-time management of a mass spectrometer and associated laboratory equipment. The overseer is a computer-based expert diagnostic system implemented on a computer separate from the dedicated computer used to control the mass spectrometer and produce the analysis results. An interface links the overseer to components of the mass spectrometer, components of the laboratory support system, and the dedicated control computer. Periodically, the overseer polls these devices and as well as itself. These data are fed into an expert portion of the system for real-time evaluation. A knowledge base used for the evaluation includes both heuristic rules and precise operation parameters. The overseer also compares current readings to a long-term database to detect any developing trends using a combination of statistical and heuristic rules to evaluate the results. The overseer has the capability ...

1991-06-18

68

Expert overseer for mass spectrometer system  

International Nuclear Information System (INIS)

This patent describes an expert overseer for the operation and real-time management of a mass spectrometer and associated laboratory equipment. The overseer is a computer-based expert diagnostic system implemented on a computer separate from the dedicated computer used to control the mass spectrometer and produce the analysis results. An interface links the overseer to components of the mass spectrometer, components of the laboratory support system, and the dedicated control computer. Periodically, the overseer polls these devices and as well as itself. These data are fed into an expert portion of the system for real-time evaluation. A knowledge base used for the evaluation includes both heuristic rules and precise operation parameters. The overseer also compares current readings to a long-term database to detect any developing trends using a combination of statistical and heuristic rules to evaluate the results. The overseer has the capability ...

1989-04-04

69

Assessment of a non-dedicated GPS receiver system for precise airborne attitude determination  

Energy Technology Data Exchange (ETDEWEB)

The use of a non-dedicated GPS receiver system for attitude determination was assessed in airborne mode through a test conducted at Sandia National Laboratories. Four independent NovAtel GPSCard{trademark} receivers were installed in Sandia`s Twin Engine Otter with two antennas mounted on the fuselage and two on the wing tips at separations of 6 to 18 m. A strapdown INS was also on board the aircraft in order to provide an independent attitude reference at rates between 4 and 10 Hz. During the multi-day test, GPS measurements were recorded between 1 and 10 Hz. Carrier phase measurements were post-processed using a double difference approach developed at The University of Calgary in which integer ambiguities were resolved in seconds using the known antenna separations as constraints. The tracking capability of the system is demonstrated under dynamics consisting of roll and pitch angles up to 45 and 12 degrees, respectively. Comparisons between the GPS and INS ...

1994-09-01

70

Use of neutron and gamma ray spectral measurements and calculations to obtain dosimetric information for DT neutrons  

Energy Technology Data Exchange (ETDEWEB)

Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 MeV is desirable. Key words: neutron--gamma spectra, spectrometry, kerma distributions, coupled multigroup calculations

1983-01-01

71

Use of neutron and gamma ray spectral measurements and calculations to obtain dosimetric information for DT neutrons  

International Nuclear Information System (INIS)

Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 MeV is desirable. Key words: neutron--gamma spectra, spectrometry, kerma distributions, coupled multigroup calculations.

7871-01-01

72

The Contribution of Sympathetic Mechanisms to Postamputation Phantom and Residual Limb Pain: A Pilot Study  

British Library Electronic Table of Contents (United Kingdom)

Postamputation pain (PAP) affects over 60% of major limb amputees. One of the main challenges in treating PAP is the difficulty involved in identifying pain mechanism(s), which pertains to both residual limb pain (RLP) and phantom limb pain (PLP). In this study, sympathetic blocks were performed on 17 major limb amputees refractory to treatment, including 2 placebo-controlled blocks done for bilateral amputations. One hour postinjection, mean RLP scores at rest declined from 5.2 (SD 2.8) to 2.8 (SD 2.6) (P = .0002), and PLP decreased from 5.3 (SD 3.1) to 2.3 (SD 2.1) (P = .0009). By 1 week, mean pain scores for RLP and PLP were 4.3 (SD 2.9) and 4.2 (SD 3.0), respectively. Overall, 8 of 16 (50%) patients experienced ?50% reduction in RLP 1-hour postinjection, with the beneficial effects ...

2011-01-01

73

TLD array for precise dose measurements in stereotactic radiation techniques  

International Nuclear Information System (INIS)

We developed a new TLD array for precise dose measurement and verification of the spatial dose distribution in small radiation targets. It consists of a hemicylindrical, tissue-equivalent rod made of polystyrene with 17 parallel moulds for an exact positioning of each TLD. The spatial resolution of the TLD array was evaluated using the Leskell spherical phantom. Dose planning was performed with KULA 4.4 under stereotactic conditions on axial CT images. In the Leksell gamma unit the TLD array was irradiated with a maximal dose of 10 Gy with an unplugged 14 mm collimator. The doses delivered to the TLDs were rechecked by diode detector and film dosimetry and compared to the computer-generated dose profile. We found excellent agreement of our measured values, even at the critical penumbra decline. For the 14 mm and 18 mm collimator and for the 11 mm collimator combination we compared the measured and calculated data at full width at half maximum. This TLD array may be ...

1996-12-01

74

Radiation exposure of children in pediatric radiology. Pt. 6. Conversion factors for reconstruction of organ dose in abdominal radiography; Zur Strahlenexposition von Kindern in der paediatrischen Radiologie. T. 6. Konversionsfaktoren zur Rekonstruktion von Organdosen bei Abdomenaufnahmen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: calculation of conversion coefficients for the reconstruction of organ doses from entrance doses for abdomen radiographs of 0, 1, 5, 10, 15, and 30-year-old patients in conventional pediatric radiology for the radiographic settings recommended by the German and European guidelines for quality management in diagnostic radiology. Materials und method: using the commercially available personal computer program PCXMC developed by the Finnish Center for Radiation and Nuclear Safety (Saeteilyturvakeskus STUK), conversion coefficients for conventional abdomen radiographs were calculated performing Monte Carlo simulations in mathematical hermaphrodite phantom models describing patients of different ages. The possible clinical variation of beam collimation was taken into consideration by defining optimal and suboptimal radiation fields on the phantoms' surfaces. Results: conversion coefficients for the reconstruction of organ does in ...

2009-10-15

75

Measurement of electron energy fluence spectra from electron beam therapy machines  

Energy Technology Data Exchange (ETDEWEB)

A technique capable of measuring the electron energy fluence spectra in a scattering medium was designed. These measurements were performed by setting a bremsstrahlung conversion target on the surface of a phantom, at an intermediate depth, and at a depth equal to electron mean range. The bremsstrahlung produced by the deceleration of electrons in the target was passed through an air channel in the phantom and passed forward by a pinhole collimator into a Na(Tl) detector. The measured pulse height data were unfolded to correct for the distortion of the spectrometer system by using the FORIST unfolding code. The unfolded bremsstrahlung spectra represent the electron energy fluence spectra convolution with the bremsstrahlung produced in the target. To generate the electron energy fluence spectra, the unfolded bremsstrahlung spectra were deconvoluted by using the MAZE2 unfolding code. CYLTRAN, a coupled electron-photon Monte Carlo transport code, ...

1984-01-01

76

FDTD analysis of body-core temperature elevation in children and adults for whole-body exposure  

Energy Technology Data Exchange (ETDEWEB)

The temperature elevations in anatomically based human phantoms of an adult and a 3-year-old child were calculated for radio-frequency whole-body exposure. Thermoregulation in children, however, has not yet been clarified. In the present study, we developed a computational thermal model of a child that is reasonable for simulating body-core temperature elevation. Comparison of measured and simulated temperatures revealed thermoregulation in children to be similar to that of adults. Based on this finding, we calculated the body-core temperature elevation in a 3-year-old child and an adult for plane-wave exposure at the basic restriction in the international guidelines. The body-core temperature elevation in the 3-year-old child phantom was 0.03 deg. C at a whole-body-averaged specific absorption rate of 0.08 W kg{sup -1}, which was 35% smaller than in the adult female. This difference is attributed to the child's higher body surface ...

2008-09-21

77

Experimental evaluation of angularly-variable fiber geometry for targeting depth-resolved reflectance from layered epithelial tissue phantoms  

Science.gov (United States)

The aim of the present study focuses on experimentally demonstrating the efficacy of using angularly-variable fiber geometry to achieve the desired tissue-layer selection and probing depths with the further objective of enhancing the sensitivity and specificity of spectral diagnosis in stratified architectures that resemble human cervical epithelia. The morphological and biochemical features of epithelial tissue vary in accordance with tissue depths; consequently, the accuracy of spectroscopic diagnosis of epithelial dysplasia may be enhanced by probing the optical properties of this tissue. When correlated to cellular dysplasia, layer-specific changes in tissue optical properties may be deciphered by reflectance spectroscopy coupled with angularly-variable fiber geometry. This study addresses the utility of using such angularly-variable fiber geometry for resolving spatially-specific spectral signatures of tissue pathology. This is accomplished by interpreting and analyzing the ...

2007-03-01

78

Construction of a homogeneous phantom for radiographic image standardization; Construcao de um fantoma homogeneo para padronizacao de imagens radiograficas  

Energy Technology Data Exchange (ETDEWEB)

The principle of radiodiagnosis consists in the fact the X-ray beam is attenuated at different degrees by distinct tissues. For this reason, the anatomical structures have distinct radiological opacities, that produce the radiographic image. The progresses in radiology are related to the development if new radiographic image formation systems that enable an amplification in the quality, with low dose and/or risk to the patient. The objective of this work is the sensitometric valuation of a screen-film combination, that is still the most used, for the standardization, of radiographic images. Thinking about this, were constructed homogeneous phantoms of the chest, skull and pelvis, for the calibration of X-ray beams, with the purpose of obtaining radiographic images of good quality, basing in the routine of a radiodiagnosis service and in the scientific knowledge. Questions were approached about the choice of the suitable equipment, that allow the obtention of k Vp ...

1996-12-31

79

Computed radiography. Evaluation of its role in the mass survey for lung cancer: Phantom study  

Energy Technology Data Exchange (ETDEWEB)

In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in the lung field and in the retrocardiac and subdiaphragmatic regions, respectively. This may have implications for the value of ...

1987-12-01

80

Computed radiography for major airway in pediatrics  

International Nuclear Information System (INIS)

This paper shows the efficacy of computed radiography for major airway in pediatrics. For this purpose, we examined 40 children (range 2 weeks to 14 years; mean 2.3 years) using Fuji Computed Radiography (FCR) and radiation dose using pediatric phantom under FCR and conventional film and screen system. In comparison study with FCR and conventional film and screen system, FCR images are superior to conventional system in all cases. Scorings were done for the quality of the image of the pharynx, the trachea, and both main bronchi. In phantom study to check radiation dose, radiation dose could be reduced 1/6 of the value using high speed film and screen and 1/15 of the value using conventional speed film and screen. FCR also showed clear airway images in all cases but technical failure to evaluate the clinical lesion. These results suggest that FCR is the adequate imaging modality to evaluate the major airway in children. (author).

1986-01-01

81

Calculating electron dose using a convolution/superposition method. 120  

International Nuclear Information System (INIS)

The calculation of electronn beam dose using an algorithms similar to convolution/superposition methods for photon beams [1,2,3,4] is explored. The distribution of dose deposited by a number of monoenergetic, point-monodirectional electron pencil beams is first determined using the Monte Carlo method [5,6]. These elementary distributions are combined to model distributions that would result from the spectrum of incident energies and angles [6,7] present in a clinical beam. These modified distributions are then stored for use as kernels in the dose calculation. In the case of a homogeneous phantom, the relative fluence distribution is convolved with the stored kernels to obtain thhe dose distributions in 3 dimensions. Since the kernels cannot be assumed to be spatially invariant in a heterogeneous water-like phantom, the dose deposited on paths from the interaction site to all the dose deposition sites is approximated by scaling the kernels to ...

82

Body dose conversion factors for computerized tomography  

International Nuclear Information System (INIS)

While there have been many experimental and calculational investigations on absorbed dose distribution in the patient resulting from conventional X-ray procedures, such data for computerized tomography (CT) are still sparse. As this diagnostic procedure has shown a rapid increase in application during recent years, we have determined absorbed dose to body organs in a human phantom resulting from CT examinations. The exposure model consists of the heterogeneous MIRD-5 phantom and a suitable Monte-Carlo method to calculate absorbed dose to organs of interest. The exposure conditions are specified according to the exposure specifications of a CT-scanner currently in use. The calculations cover the range of body tissues of interest in terms of organ absorbed doses as well as a risk weighted absorbed dose. A detailed example showing the calculation of red bone marrow dose is given and a somatic effective dose equivalent Hsub(ES) is calculated for ...

1980-10-31

83

Analysis on Dose Distribution in Heterogeneous Condition for Narrow 6 MV X-ray Beams  

International Nuclear Information System (INIS)

Advanced modality of high-precision radiotherapy fulfilled by a composition of large numbers of small field beams called 'beamlets' can be achieved via nonuniform intensity fluencies. In case of radiation measurements and calculations with narrow high-energy photon beams, however, an accurate two-dimensional dosimetry is a challenging task due to dosimetrically unfavorable phenomena such as dramatic changes of the dose at the field boundaries, dis-equilibrium of the electrons resulting from larger detector volume, and non-uniformity between the detector and the phantom materials. Meanwhile, with the advantages of high spatial resolution and wide range of absorbed doses, there is a growing demand of GAFCHROMICat..EBT film to confirm delivered dose distribution. Especially, the effects from the material differences between the phantom and the film can be minimized in the heterogeneous condition since the GAFCHROMICat..EBT film is composed of ...

2010-10-01

84

An adaptive filter to approximate the Bayesian strategy for sonographic beamforming.  

Science.gov (United States)

A first-principles task-based approach to the design of medical ultrasonic imaging systems for breast lesion discrimination is described. This study explores a new approximation to the ideal Bayesian observer strategy that allows for object heterogeneity. The new method, called iterative Wiener filtering, is implemented using echo data simulations and a phantom study. We studied five lesion features closely associated with visual discrimination for clinical diagnosis. A series of human observer measurements for the same image data allowed us to quantitatively compare alternative beamforming strategies through measurements of visual discrimination efficiency. Employing the Smith-Wagner model observer, we were able to breakdown efficiency estimates and identify the processing stage at which performance losses occur. The methods were implemented using a commercial scanner and a cyst phantom to explore development of spatial filters for systems ...

2010-07-19

85

A convolution/superposition method using primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance: a theoretical study on 10-MV X-ray dose calculations in thorax-like phantoms  

British Library Electronic Table of Contents (United Kingdom)

A convolution/superposition method is proposed for use with primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. It should be noted that the number of energy bins is usually about ten, and that the reconstructed X-ray spectra can reasonably be applied to media with a wide range of effective Z numbers, ranging from water to lead. The study was carried out for 10-MV X-ray doses in water and thorax-like phantoms with the use of open-jaw-collimated fields. The dose calculations were made separately for primary, scatter, and electron contamination dose components, for which we used two extended radiation sources: one was on the X-ray target and the other on the flattening filter. To calculate the in-air beam intensities at po...

2011-01-01

86

Transmutation of {sup 241}Am in a high thermal neutron flux  

Science.gov (United States)

Amongst the minor actinides issued from the spent nuclear fuel, {sup 241}Am is present in high concentration and contributes significantly to the long-term radiotoxicity of nuclear waste. A major uncertainty was present in the transmutation chain of {sup 241}Am when irradiated by a high intensity thermal neutron flux. This uncertainty was brought about by the poor knowledge of the {sup 242gs}Am neutron capture cross section. A dedicated experiment has been performed at the Institut Laue-Langevin in Grenoble, which gives a definitive experimental answer to this problem.

1998-10-26

87

Transmutation of "2"4"1Am in a high thermal neutron flux  

International Nuclear Information System (INIS)

Amongst the minor actinides issued from the spent nuclear fuel, "2"4"1Am is present in high concentration and contributes significantly to the long-term radiotoxicity of nuclear waste. A major uncertainty was present in the transmutation chain of "2"4"1Am when irradiated by a high intensity thermal neutron flux. This uncertainty was brought about by the poor knowledge of the "2"4"2"g"sAm neutron capture cross section. A dedicated experiment has been performed at the Institut Laue-Langevin in Grenoble, which gives a definitive experimental answer to this problem.

1998-10-26

88

The ArgoNeuT LAr-TPC: A dedicated experiment for neutrino cross section measurement at FNAL  

British Library Electronic Table of Contents (United Kingdom)

ArgoNeuT, a Liquid Argon Time Projection Chamber (LAr-TPC), has recently collected thousands of neutrino and anti-neutrino events between 0.1 and 10 GeV in the NuMI beamline at Fermilab (FNAL). Among other issues, the experiment will measure the cross section of the neutrino and anti-neutrino Charged Current Quasi-Elastic (CCQE) interaction on Ar target and analyze the vertex activity associated with such events. Outcomes from the reconstruction of the events provide the main subject of this paper.

2011-01-01

89

Teamwork in Multi-Agent Systems A Formal Approach  

CERN Document Server

What makes teamwork tick?. Cooperation matters, in daily life and in complex applications. After all, many tasks need more than a single agent to be effectively performed. Therefore, teamwork rules!. Teams are social groups of agents dedicated to the fulfilment of particular persistent tasks. In modern multiagent environments, heterogeneous teams often consist of autonomous software agents, various types of robots and human beings. Teamwork in Multi-agent Systems: A Formal Approach explains teamwork rules in terms of agents' attitudes and their complex interplay. It provides the first comprehe

2010-01-01

90

Status and Challenges of the LHC Construction  

CERN Document Server

The LHC is designed to provide proton beams of 7 TeV and nominal luminosity of 10**34 cm**-2s**-1. This objective is achieved at an affordable cost by pushing all major collider components to the limits of technology, by upgrading the existing CERN accelerators and infrastructure, and by involving the technical expertise, resources and dedication of accelerator laboratories world-wide. Following a decade of intensive R&D and technical validation of major collider systems, the LHC construction is now fully underway. Major industrial contracts have been awarded and are in execution for the procurement of the magnet, cryogenics and other systems. In this report, the status of the design and construction of the major LHC systems is presented.

2001-01-01

91

Smart Acquisition EELS  

Energy Technology Data Exchange (ETDEWEB)

Electron energy loss (EEL) spectroscopy and high angle annular dark field (HAADF) imaging in aberration-corrected electron microscopes are powerful techniques to determine the chemical composition and structure of materials at atomic resolution. We have implemented Smart Acquisition, a flexible system of scanning transmission electron microsocpy (STEM) beam position control and EELS collection, on two aberration-corrected dedicated cold field emission gun (FEG) STEMs located at SuperSTEM, Daresbury Laboratory. This allows the collection of EEL spectra from spatially defined areas with a much lower electron dose possible than existing techniques such as spectrum imaging.

2010-07-01

92

Review of ion accelerators  

Energy Technology Data Exchange (ETDEWEB)

The field of ion acceleration to higher energies has grown rapidly in the last years. Many new facilities as well as substantial upgrades of existing facilities have extended the mass and energy range of available beams. Perhaps more significant for the long-term development of the field has been the expansion in the applications of these beams, and the building of facilities dedicated to areas outside of nuclear physics. This review will cover many of these new developments. Emphasis will be placed on accelerators with final energies above 50 MeV/amu. Facilities such as superconducting cyclotrons and storage rings are adequately covered in other review papers, and so will not be covered here.

1990-06-01

93

Research, Preservation, and Education: An Introduction to Various Heritage Centers, Organizations, and Projects  

British Library Electronic Table of Contents (United Kingdom)

This forum showcases the work of a variety of different heritage-based centers, organizations, and projects dedicated to research, education, and preservation of tangible and intangible forms of cultural heritage. The descriptions of these centers demonstrate the diversity of heritage work being done today. The centers and projects described in the forum vary in their contexts, missions, and outcomes. Highlighted in the forum are preservation organizations, university-based heritage centers, and a global collaborative cultural heritage project. Each organization in the forum provides information about their missions and goals, their approaches or methods to heritage work, and a brief description of some of their initiatives.

2011-01-01

94

Numerical study of semi-molten droplet impingement  

British Library Electronic Table of Contents (United Kingdom)

Due to the low thermal conductivity of ceramics large temperature gradients are present through the powder particles during plasma spray deposition. As a result the particles often impinge at the substrate in a semi-molten form; which in turn substantially affects the final characteristics of the coating being formed. This study is dedicated to the novel modelling development and simulation of a semi-molten droplet impingement. The study examines the impingement process during impact, spreading and solidification of semi-molten zirconia. The simulation provides an insight to the heat transfer process during impact and solidification of a semi-molten powder particle and illustrates the freezing-induced break-up mechanism at the splat periphery.

2011-01-01

95

Neuroinflammation and brain infections: Historical context and current perspectives  

British Library Electronic Table of Contents (United Kingdom)

An overview of current concepts on neuroinflammation and on the dialogue between neurons and non-neuronal cells in three important infections of the central nervous systems (rabies, cerebral malaria, and human African trypanosomiasis or sleeping sickness) is here presented. Large numbers of cases affected by these diseases are currently reported. In the context of an issue dedicated to Camillo Golgi, historical notes on seminal discoveries on these diseases are also presented. Neuroinflammation is currently closely associated with pathogenetic mechanisms of chronic neurodegenerative diseases. Neuroinflammatory signaling in brain infections is instead relatively neglected in the neuroscience community, despite the fact that the above infections provide paradigmatic examples of alterations o...

2011-01-01

96

Laboratory robotics projects in the Analytical Development Division at the Savannah River Laboratory  

International Nuclear Information System (INIS)

To encourage the application of robotics technology for routine radiobench applications, a laboratory dedicated to the research and development of contained robotic systems is being constructed. The facility will have several robots located in laminar flow hoods, and the hoods are being designed to allow the possibility for multiple robots to work together. This paper presents both the design features of the hoods and the general layout of the laboratory, and also discusses an application of a robotic system for the routine nuclear counting of gamma tube samples. The gamma tube system is presently operating in one of the routine analysis laboratories. 5 figs.

97

Dentascan CT of mandibular incisive canal. Radiological anatomy and therapeutic implications  

International Nuclear Information System (INIS)

The main purpose of this paper is to stress the importance of CT depiction of the mandibular incisive canal. This anatomical structure contains a major neurovascular bundle and is thus very important in the planning of mandibular implants in the canine-incisive area. The importance of careful assessment of the mandibular canal course before implantology is now widely recognized. The same holds true for the canine-incisive region in the jaw, to detect the incisive canal if present and prevent any complications from its accidental damage. CT with a dedicated software showed the incisive canal in a large number of patients, which calls for precise reporting of its presence, course, and relationships with teeth.

1999-11-01

98

Daya Bay Neutrino Experiment: Goal, Progress and Schedule  

CERN Document Server

Daya Bay Neutrino Experiment is dedicated to measuring the last unobserved neutrino mixing angle theta_13. The predicted precision on sin^2(2theta_13) is 0.01 at 90% confidence level. This document briefly reviews the measurement method and detector construction status. The first two anti-neutrino detectors' dry run result is also discussed. The Daya Bay near hall data taking is expected to commence in the summer of 2011 and the data taking of all of the three halls in the summer of 2012.

2011-01-01

99

A South African perspective  

Energy Technology Data Exchange (ETDEWEB)

A discussion of the Sasol I, II, and III coal liquefaction plants of the Republic of South Africa was presented. The technology, capacity, and economics of these projects were included in the discussion. These plants utilize the Fischer-Tropsch process of indirect coal liquefaction and produce a barrel of synthetic crude for about $55 (or about $20 above current market prices). Outlines of the differences in indirect coal liquefaction and newer direct methods were presented. It was determined that the South African dedication to coal liquefaction was made more for the political aspects of energy independence than economics.

1983-02-01

100

A Framework for Understanding Golfing Visitors to a Destination  

British Library Electronic Table of Contents (United Kingdom)

The purpose of this study is to determine whether there are differences among visitors to a destination based on their golfing frequency in the previous year. By constructing a framework for understanding the golf traveller, golf and tourism industry representatives can better understand the contribution that golfers make to a destination based on factors such as satisfaction, perceived value received from the golfing experience, trip length, expenditures, travel decisions, and motivations. The results indicate that there are significant differences between golfers based on golfing frequency. Dedicated golfers are very different from infrequent and moderate golfers on three of the four variables used to profile these visitors. Findings from this research may provide golf and tourism market...

2008-01-01

101

Radiation exposure of patients and operators during interventional radiology  

International Nuclear Information System (INIS)

Surface doses received by patients and operators were measured during 30 interventional radiological procedures (ten percutaneous transhepatic biliary drainages, ten percutaneous nephrostomies, ten percutaneous transluminal angioplasties). In addition, organ doses to the patient were determined using an Alderson-Rando phantom. These served as a basis for calculating the so-called somatic dose indices. It was found that the somatic radiation risk to the patient is relatively small despite prolonged periods of fluoroscopy. However, exposure of the hands and lenses of the operator could easily reach the limits thought acceptable while carrying out these procedures with additional angiography. (orig).

1986-01-01

102

Organ doses to atomic bomb survivors during photofluorography, fluoroscopy and computer tomography  

Energy Technology Data Exchange (ETDEWEB)

Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).

1991-08-01

103

Organ doses to atomic bomb survivors during photofluorography, fluoroscopy and computer tomography  

International Nuclear Information System (INIS)

Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).

1991-01-01

104

Organ doses and integral doses in X-ray diagnosis of the chest and of the head  

International Nuclear Information System (INIS)

Organ and tissue doses and integral doses in patients due to diagnostic x-ray examinations of the chest and of the head will be presented. These data have been obtained by measuring the dose distributions in man phantoms by LiF-dosimetry. The data will be compared with data obtained by Monte-Carlo calculations. To obtain average organ doses for a special type of examination for the population or for a specified subpopulation in the variation of the exposure, data due to the different techniques used by the different radiologists has to be known. Such data will be presented. The results of the investigation will be discussed in connection with the concept of the 'somatic significant.

1977-04-01

105

Mathematical child phantom for the calculation of dose to the organs at risk  

Energy Technology Data Exchange (ETDEWEB)

In order to calculate the doses received by the organs of 530 children treated by radiation for cancer between 1945 and 1969 at the G. Roussy Institute, we have developed a computer program for organ location calculation. To calculate the location of each child's organs of interest at the time of the treatment, only two parameters are necessary; sex and height or sex and age when the height at the time of the treatment is unknown. The algorithm is based on the metric studies of growth known as auxology. Each organ is located by one point representing its center. The model has been checked on 100 healthy children.

1988-05-01

106

Electron beam therapy in carcinoma of the buccal mucosa  

Energy Technology Data Exchange (ETDEWEB)

Electron beam therapy has often been used for radiation therapy of carcinomas of the buccal mucosa, though side effects, including stomatitis and dermatitis, are known to exist. We experimented using the additional back scatter and transit with the phantom under a lead plate within the irradiation field, in order to better focus the dose on the target volume moreover, we fabricated a mouthpiece fitted with a lead plate shaped to the target volume, and with respect to the influence of the mouthpiece on stomatitis and dermatitis, obtained good clinical results. (author).

1990-10-01

107

Electron beam therapy in carcinoma of the buccal mucosa  

International Nuclear Information System (INIS)

Electron beam therapy has often been used for radiation therapy of carcinomas of the buccal mucosa, though side effects, including stomatitis and dermatitis, are known to exist. We experimented using the additional back scatter and transit with the phantom under a lead plate within the irradiation field, in order to better focus the dose on the target volume moreover, we fabricated a mouthpiece fitted with a lead plate shaped to the target volume, and with respect to the influence of the mouthpiece on stomatitis and dermatitis, obtained good clinical results. (author).

108

Dual-field rotational (DFR) technique for total-skin electron-beam therapy (TSEBT)  

Energy Technology Data Exchange (ETDEWEB)

Comparison of dosimetry measured in a noncylindrical Rando-Alderson phantom by two-field, four-field, and six-field total-skin electron-beam therapy (TSEBT) techniques with our dual-field rotational (DFR) technique reveals a superior dosimetry for the latter. Our technique of dual-field rotational DFR-TSEBT is described in detail, and its advantages and indications for the primary management of cutaneous T-cell lymphoma (CTCL) and Kaposi's sarcoma (KS) are discussed.

1987-08-01

109

Clinical implementation of a convolution based algorithm for 3D treatment planning  

International Nuclear Information System (INIS)

Purpose/Objective: With the advent of computed tomography and magnetic resonance imaging, the three dimensional representation of the patient anatomy has become an invaluable resource for better diagnosis and delineation of the target volume and sensitive structures in radiation therapy. Although the therapeutic linear accelerator industry has made available highly sophisticated equipment, the aggressiveness in dose prescription and delivery has to be complimented by accurate dose computation methods. We have adopted a convolution/superposition algorithm for the calculation of absolute dose that fully accounts for the external shape and internal structure of the patient for photon treatment radiotherapy. In this paper, we will discuss the principles of the convolution algorithm and we will show how the computed dose compares to clinically relevant treatment techniques. Materials and Methods: A computer controlled data acquisition system and a water tank where used to measure depth ...

110

A new type active personal dosemeter with a solid state detector  

International Nuclear Information System (INIS)

We have developed a new type personal dosemeter by using a B-10 doped silicon p-n junction detector with a polyethylene radiator and a polyethylene moderator. The purpose of this study was to develop a real time neutron dosemeter with a nearly flat response in the energy range from thermal to 15 MeV and low angular dependence to the incident neutron direction. The neutron response of the dosemeter was obtained with the Monte Carlo calculation and the monoenergetic neutron experiment in a free air field and also under a condition attached on a phantom.

1988-04-01

111

Experimental studies of compact real-time neutron dosimeters  

International Nuclear Information System (INIS)

Full text: Semiconductor detectors coated with boron or lithium compounds have been studied for neutron detection for decades but, until recently, have been limited to thermal neutron detection efficiencies of less than 5%. We reported previously on development and simulation studies of perforated detectors whose perforations are filled with neutron-reactive material in order to produce higher detection efficiencies. Incorporation of bare and cadmium-backed detectors into battery-powered devices with low-power electronics enables us to produce compact personal neutron dosimeters that provide LED readout of counts, which can be related approximately to neutron dose. We report here on experimental studies with such compact devices; devices capable of direct readout in dose units are anticipated. The thermal and epithermal neutron flux densities from the tangential beam tube of the TRIGA Mark II reactor at Kansas State University were measured. Then, thermoluminescent dosimeters (some ...

2008-06-01

112

Convolution/superposition using the Monte Carlo method  

International Nuclear Information System (INIS)

The convolution/superposition calculations for radiotherapy dose distributions are traditionally performed by convolving polyenergetic energy deposition kernels with TERMA (total energy released per unit mass) precomputed in each voxel of the irradiated phantom. We propose an alternative method in which the TERMA calculation is replaced by random sampling of photon energy, direction and interaction point. Then, a direction is randomly sampled from the angular distribution of the monoenergetic kernel corresponding to the photon energy. The kernel ray is propagated across the phantom, and energy is deposited in each voxel traversed. An important advantage of the explicit sampling of energy is that spectral changes with depth are automatically accounted for. No spectral or kernel hardening corrections are needed. Furthermore, the continuous sampling of photon direction allows us to model sharp changes in fluence, such as those due to collimator ...

2003-07-21

113

Comparison of dose calculation algorithms in phantoms with lung equivalent heterogeneities under conditions of lateral electronic disequilibrium  

International Nuclear Information System (INIS)

An extensive set of benchmark measurement of PDDs and beam profiles was performed in a heterogeneous layer phantom, including a lung equivalent heterogeneity, by means of several detectors and compared against the predicted dose values by different calculation algorithms in two treatment planning systems. PDDs were measured with TLDs, plane parallel and cylindrical ionization chambers and beam profiles with films. Additionally, Monte Carlo simulations by meansof the PENELOPE code were performed. Four different field sizes (10x10, 5x5, 2x2, and1x1 cm"2) and two lung equivalent materials (CIRS, #rho#_e"w=0.195 and St. Bartholomew Hospital, London, #rho#_e"w=0.244-0.322) were studied. The performance of four correction-based algorithms and one based on convolution-superposition was analyzed. The correction-based algorithms were the Batho, the Modified Batho, and the Equivalent TAR implemented in the Cadplan (Varian) treatment planning system and the TMS Pencil Beam ...

2004-10-01

114

Application of low-dose radiation protocols in survey CT scans  

International Nuclear Information System (INIS)

Objective: To characterize the protocols with low-dose radiation in survey CT scans for localization. Methods: Eighty standard adult patients, head and body phantoms were recruited. Default protocols provided by operator's manual setting were that all the tube voltage for head, chest, abdomen and lumbar was 120 kV; the tube currents were 20,10,20 and 40 mA, respectively. Values of kV and mA in the low-dose experiments were optimized according to the device options. For chest and abdomen, the tube position were compared between default (0 degree) and 180 degree. Phantoms were scanned with above protocols, and the radiation doses were measured respectively. Paired t-test were used for comparisons of standard deviation in CT value, noise and exposure surface dose (ESD) between group with default protocols and group with optimized protocols. Results: The optimized protocols in low-dose CT survey scans were 80 kV, 10 mA for head, 80 kV, 10 mA for ...

2009-08-01

115

Accuracy of two heterogeneity dose calculation algorithms for IMRT in treatment plans designed using an anthropomorphic thorax phantom  

International Nuclear Information System (INIS)

With the advent of intensity-modulated radiation therapy (IMRT), the inclusion of heterogeneity corrections is further complicated by the conformal delivery of many small beams forming steep dose gradients. Radiation treatment planning has evolved to take into account even small changes in tissue density so that the dose to tumor can be further optimized. However, different treatment planning systems incorporate different heterogeneity correction algorithms, and it is unclear whether any of these algorithms are superior to others in terms of accurately predicting delivered radiation doses relative to measurement in a clinical setting. The purpose of this study was to determine the accuracy of heterogeneity dose calculations from two widely used IMRT treatment planning systems (Pinnacle and Corvus) against measurement. These two systems handle heterogeneity dose corrections by means of a collapsed-cone convolution superposition algorithm and a finite-size pencil-beam algorithm with ...

2007-05-01

116

The search for decaying Dark Matter  

CERN Document Server

We propose an X-ray mission called Xenia to search for decaying superweakly interacting Dark Matter particles (super-WIMP) with a mass in the keV range. The mission and its observation plan are capable of providing a major break through in our understanding of the nature of Dark Matter (DM). It will confirm, or reject, predictions of a number of particle physics models by increasing the sensitivity of the search for decaying DM by about two orders of magnitude through a wide-field imaging X-ray spectrometer in combination with a dedicated observation program. The proposed mission will provide unique limits on the mixing angle and mass of neutral leptons, right handed partners of neutrinos, which are important Dark Matter candidates. The existence of these particles is strongly motivated by observed neutrino flavor oscillations and the problem of baryon asymmetry of the Universe. In super-WIMP models, the details of the formation of the cosmic web are different from ...

2009-01-01

117

The duke XUV FEL storage ring facility  

Energy Technology Data Exchange (ETDEWEB)

In this paper we present status and developments of the Duke storage ring facility. The Duke storage ring facility provides the unique combination of phase-locked light sources ranging from high power OK-4 XUV FEL to quasimonochromatic {gamma}-ray beam and IR/X-ray spontaneous radiation. The XUV OK-4 FEL, which is collaborative project with BlNP, Novosibirsk, is in operation since November, 1996. The OK-4 UV FEL is also used for production of nearly monochromatic {gamma}-ray s with tunable energy. We present the results of UV lasing with the OK4 FEL and selected results of its applications. We will discuss our future plans for extension of this source and status of the construction of dedicated used facility adjacent to the FEL building. (author)

1998-11-01

118

The Benchmark Test Results of QNX RTOS  

International Nuclear Information System (INIS)

A Real-Time Operating System(RTOS) is an Operating System(OS) intended for real-time applications. Benchmarking is a point of reference by which something can be measured. The QNX is a Real Time Operating System(RTOS) developed by QSSL(QNX Software Systems Ltd.) in Canada. The ELMSYS is the brand name of commercially available Personal Computer(PC) for applications such as Cabinet Operator Module(COM) of Digital Plant Protection System(DPPS) and COM of Digital Engineered Safety Features Actuation System(DESFAS). The ELMSYS PC Hardware is being qualified by KTL(Korea Testing Lab.) for use as a Cabinet Operator Module(COM). The QNX RTOS is being dedicated by Korea Atomic Energy Research Institute (KAERI). This paper describes the outline and benchmarking test results on Context Switching, Message Passing, Synchronization and Deadline Violation of QNX RTOS under the ELMSYS PC platform

2010-10-01

119

Temperature measurement of 6He?+? ions confined in a transparent Paul trap  

British Library Electronic Table of Contents (United Kingdom)

The LPCTrap setup is a transparent Paul trap dedicated to the measurement of the ??? correlation coefficient a ?? in the ? decay of trapped radioactive nuclides. In a first experiment, the system has been used to record ?105 coincidences between the ? particles and recoiling ions emitted from the decay of 6He?+? ions. The analysis of the collected data has already shown that the size of the 6He?+? ion cloud confined in the Paul trap is a critical parameter, potentially limiting the accuracy on the a ?? measurement. We report here the precise determination of the trapped ion cloud temperature and size. This was performed by extracting the trapped ions toward a position sensitive micro channel plate detector at different phases of the RF driving field. We find a temperature T exp ?= 0.107(7)...

2011-01-01

120

Sequential chemical treatment of radium species in TENORM waste sludge produced from oil and natural gas production  

British Library Electronic Table of Contents (United Kingdom)

This paper is dedicated to the treatment of sludge occurring in frame of the Egyptian produced from oil and gas production. The activity levels of three radium isotopes: Ra-226 (of U-series), Ra-228 and Ra-224 (of Th-series) in the solid TENORM waste (sludge) were first evaluated and followed by a sequential treatment for all radium species (fractions) presented in TENORM. The sequential treatment was carried out based on two approaches `A' and `B' using different chemical solutions. The results obtained indicate that the activity levels of all radium isotopes (Ra-226, Ra-228 and Ra-224) of the environmental interest in the TENORM waste sludge were elevated with regard to exemption levels established by IAEA [International Atomic Energy Agency (IAEA), International basic safety standards f...

2009-01-01

121

Research and development environmental activities at CANMET; Les activites environnementales de R et D chez CANMET  

Energy Technology Data Exchange (ETDEWEB)

The Canada Centre for Mineral and Energy Technology (CANMET) is a research organization dedicated to the advancement of the Canadian mining industry. It specializes in the development of new technologies and the coordination of scientific partnerships in the fields of mines, metallurgical processes, and the environment. CANMET supports a number of research and development activities related to the mining industry. In this poster presentation, the author described the mandate of CANMET by first introducing the organization chart with a special emphasis placed on the Mining and Mineral Sciences Laboratories. A description of the different types of partnerships was included, followed by specific details concerning all the projects related to the mining industry, such as terrain control, automation of mines, underground mining environment, processes and services, analytical support, environmental programs, mine effluent, waste rock and tailings, and metals and the ...

2000-07-01

122

Renewable energy [systems in buildings]; Duurzame energie [in gebouwen  

Energy Technology Data Exchange (ETDEWEB)

As a result of a lower value of the energy efficiency coefficient (EPC) for houses and the implementation of the Energy Performance Building Directive (EPBD), both in 2006, the interest in applying renewable energy systems is growing. Therefore, this issue is dedicated to renewable energy and related energy systems. [Dutch] Het begrip 'duurzaam' is van toepassing op twee pijlers: een pijler betreft het gebruik van duurzame materialen, de tweede pijler is duurzame energie. Door verlaging van de Energieprestatiecoefficient (EPC) voor woningen per 2006 en de invoering van de Europese richtlijn Energy Performance Building Directive (EPBD) in 2006, krijgt duurzame energie een nieuwe impuls. Reden voor de redactie van ThemaTech om deze aflevering te wijden aan duurzame energie en verwante ystemen.

2005-05-15

123

Real-time neutron radiography applications in dynamic fluid flow studies  

Energy Technology Data Exchange (ETDEWEB)

Real-time neutron radiography (RTNR) is now proving to be a valuable research tool in the study of hydrogenous fluid flow. One of the most significant advantages of neutron radiography is the ability to image hydrogenous substances (such as lubricants, coolants, and fuels) inside metallic materials such as aluminum and titanium engines. By using RTNR, one can then study dynamic events such as the movement of liquids inside these solids. The Phoenix Memorial Laboratory (PML) at the University of Michigan has recently developed and installed a facility dedicated to RTNR. The work at PML has shown that RTNR of dynamic events can provide information enabling the researcher to follow dynamic events that were previously impossible or impractical. This paper will show the variety of uses of RTNR presently being pursued at PML.

1986-01-01

124

Real-time neutron radiography applications in dynamic fluid flow studies  

International Nuclear Information System (INIS)

Real-time neutron radiography (RTNR) is now proving to be a valuable research tool in the study of hydrogenous fluid flow. One of the most significant advantages of neutron radiography is the ability to image hydrogenous substances (such as lubricants, coolants, and fuels) inside metallic materials such as aluminum and titanium engines. By using RTNR, one can then study dynamic events such as the movement of liquids inside these solids. The Phoenix Memorial Laboratory (PML) at the University of Michigan has recently developed and installed a facility dedicated to RTNR. The work at PML has shown that RTNR of dynamic events can provide information enabling the researcher to follow dynamic events that were previously impossible or impractical. This paper will show the variety of uses of RTNR presently being pursued at PML.

1986-11-16

125

Properties of molecular solids and fluids at high pressure and temperatures  

Energy Technology Data Exchange (ETDEWEB)

This renewal request for DOE grant DE-FG02-86ER45238, is dedicated to providing a complete thermodynamic profile of solids fluids, and fluid mixtures, over a wide range of temperatures and pressures. We are partially motivated by technological interest in detonation, combustion, superhard high pressure materials, and high temperature superconductors, which are important components of interest of various DOE laboratories. Our work on fluids and solids, composed of simple molecules, involves the determination of structures, phase transitions, pressure-volume relations, phonon, vibron, and libron modes of excitation, sound velocities, specific heats, thermal expansion, virial coefficients, sublimation energies, and orientational translational, and magnetic correlations. We hope that the study of these systems under extreme thermodynamic conditions will lead to exotic new materials of value, as well as enhanced fundamental understanding.

1992-03-01

126

Pipework design and operation  

Energy Technology Data Exchange (ETDEWEB)

This book presents the proceedings of a conference dedicated to the design and operation of pipework in all its aspects, involving both metallic and non-metallic materials. Topics considered include a study of single mitre pipe bends using the finite element method; tests to failure of GRP pipe bends under in-plane flexural loading; finite element stress analysis of an equal diameter branch pipe intersection subjected to internal pressure and in-plane moment loadings; finite element stress analysis of extruded outlet tee junctions; design of pipework on the British PWR; a review of advanced remanent life methods for pipes operating in the creep range; pipe whip analysis and design; damping values for piping systems; pipework snubbers based on electro-rheological fluids; and the seismic design of piping systems in the flexible range.

1985-01-01

127

Operation of beam line facilities for real-time x-ray studies at Sector 7 of the advanced photon source. Final Report  

Energy Technology Data Exchange (ETDEWEB)

This Final Report documents the research accomplishments achieved in the first phase of operations of a new Advanced Photon Source beam line (7-ID MHATT-CAT) dedicated to real-time x-ray studies. The period covered by this report covers the establishment of a world-class facility for time-dependent x-ray studies of materials. During this period many new and innovative research programs were initiated at Sector 7 with support of this grant, most notably using a combination of ultrafast lasers and pulsed synchrotron radiation. This work initiated a new frontier of materials research: namely, the study of the dynamics of materials under extreme conditions of high intensity impulsive laser irradiation.

2003-09-10

128

Nuclear forensic investigations with a focus on plutonium  

International Nuclear Information System (INIS)

Since the beginning of the 1990s when the first seizures of nuclear material were reported, the IAEA has recorded over 200 cases of illicit trafficking of nuclear materials. Despite the decreasing frequency of nuclear material seizures, particularly the ones involving weapons-grade material, the issue continues to attract public attention and is a reason for concern due to the hazard associated with such materials. Once illicitly trafficked nuclear material has been intercepted, the questions of its intended use and origin are to be addressed. Especially the origin is of prime importance in order to close the gaps and improve the physical protection at the sites where the theft or diversion occurred. To answer these questions, a dedicated nuclear forensics methodology has been developed. In this paper an overview is given on the methodologies used, on the past and on-going developments and on the experience gathered. Some selected examples shall illustrate the ...

2007-10-11

129

New procedures. Comprehensive staging of lung cancer by MRI  

International Nuclear Information System (INIS)

Lung cancer staging according to the TNM system is based on morphological assessment of the primary cancer, lymph nodes and metastases. All aspects of this important oncological classification are measurable with MRI. Pulmonary nodules can be detected at the clinically relevant size of 4-5 mm in diameter. The extent of mediastinal, hilar and supraclavicular lymph node affection can be assessed at the same time. The predominant metastatic spread to the adrenal glands and spine can be detected in coronal orientation during dedicated MRI of the lungs. Search focused whole body MRI completes the staging. Various additional MR imaging techniques provide further functional and clinically relevant information during a single examination. In the oncological context the most important techniques are imaging of perfusion and tumor motion. Functional MRI of the lungs complements the pure staging and improves surgical approaches and radiotherapy planning. (orig.)

2010-08-01

130

Network management of real-time embedded processors  

International Nuclear Information System (INIS)

The Superconducting super Collider Laboratory is a complex of particle accelerators being built in Ellis County, Texas. It will have a dedicated global communications network that will deliver control messages and provide for general data acquisition. This network will connect thousands of computer nodes over a very large geographic area. In order to meet the demanding availability requirements being levied on the system, it will need comprehensive network management. A large number of the computer nodes are embedded systems that traditionally do not support network management services. This presents unique challenges to standard network management practices. The Simple Network Management Protocol, SNMP, is widely accepted by industry as a tool to manage network devices. In this paper the authors examine the performance characteristics and usefulness of an SNMP agent in a real-time environment.

1993-05-17

131

Natural convection cooling of the IFMIF target and test cell  

International Nuclear Information System (INIS)

The present work summarizes efforts on the simulation of natural convection cooling within the IFMIF target and test cell. The simulations have been performed with the STAR-CD code using the k-#omega# high-Reynolds number turbulence model. A dedicated thermohydraulic model has been devised including Lithium loop components. Nuclear heat production has been calculated by the Monte-Carlo code McDeLicious for different parts of the target and test cell walls and was used as input for the STAR-CD simulations. Helium atmospheres at several pressures from 0.1 to 10"-"5 MPa have been investigated. In order to limit the maximum temperature of the concrete walls to 80 deg. C it was necessary to add thermal insulation layers to the hot Lithium loop surfaces and a conceptual system of two cooling layers in different depths of the concrete walls.

2007-10-01

132

Multiprocessors and Asynchronous Event Handling in the Real-Time Specification for Java  

British Library Electronic Table of Contents (United Kingdom)

The Real-Time Specification for Java (RTSJ) is silent on multiprocessor issues. It attempts not to preclude multiprocessor implementations but provides no direct support. Many areas of the RTSJ leave an implementation considerable freedom on how it provides the defined functionality. One such area is the asynchronous event handling (AEH) model. Events are fired and associated handlers are scheduled for execution in response; handlers have defined scheduling parameters and deadlines. The primary goal of the AEH model is to support a lightweight real-time concurrency model. Hence handlers, in general, do not have dedicated threads. Rather, the implementation is responsible for ensuring that all handlers meet their deadlines. Typically real-time threads are assigned to execute handlers by the...

2011-01-01

133

Measurement of the photon-proton total cross section at a center-of-mass energy of 209 GeV at HERA  

Energy Technology Data Exchange (ETDEWEB)

The photon-proton total cross section has been measured in the process e{sup +}p{yields}e{sup +}{gamma}p{yields}e{sup +}X with the ZEUS detector at HERA. Events were collected with photon virtuality Q{sup 2}<0.02 GeV{sup 2} and average {gamma}p center-of-mass energy W{sub {gamma}}{sub p}=209 GeV in a dedicated run, designed to control systematic effects, with an integrated luminosity of 49 nb{sup -1}. The measured total cross section is {sigma}{sub tot}{sup {gamma}}{sup p}=174{+-}1 (stat.){+-}13 (syst.) {mu}b. The energy dependence of the cross section is compatible with parameterizations of high-energy pp and pp-bar data.

2002-04-15

134

Influences of material inhomogeneities in 100Cr6 steel on the electrochemical metal dissolution process  

Energy Technology Data Exchange (ETDEWEB)

The electrochemical metal dissolution of 100Cr6 steel in sodium chloride solution, applying high electrolyte flow rates and high current densities, has been studied with a view to the influence of material heterogeneities such as carbide segregation lines in the steel matrix. It was shown that the presence of such segregations is responsible for the formation of troughs on the specimen surface during electrochemical dissolution. A mechanism for trough formation was proposed. A dedicated heat treatment applied to the 100Cr6 steel eliminated the carbide segregation lines and established a soft annealed, fine-grained microstructure containing globular carbides. Subsequent electrochemical dissolution did not show any development of surface irregularities as troughs. (orig.)

2001-05-01

135

High channel density wavelength division multiplexer with defined diffracting means positioning  

Energy Technology Data Exchange (ETDEWEB)

A wavelength division multiplexer/demultiplexer having optical path lengths between a fiber array and a Fourier transform lens, and between a dispersion grating and the lens equal to the focal length of the lens. The optical path lengths reduce losses due to angular acceptance mismatch in the multiplexer. Close orientation of the fiber array about the optical axis and the use of a holographic dispersion grating reduces other losses in the system. Multi-exposure holographic dispersion gratings enable the multiplexer/demultiplexer for extremely broad-band simultaneous transmission and reflection operation. Individual Bragg plane sets recorded in the grating are dedicated to and operate efficiently on discrete wavelength ranges.

1990-01-01

136

Government-industry-education collaboration for intelligent tutor computer labs  

Energy Technology Data Exchange (ETDEWEB)

Through the dedicated collaborative efforts of many individuals interested in supporting local education, computer laboratories were established at two urban high schools. The purchasing and implementation of the project was handled by the Alliance for Education, a local non-profit education advocate. Funds were supplied by the Air Force as part of a 3-year research activity utilizing artificial intelligence technology to tutor 9th grade students. NCR (now AT7T Global Information Solutions) corporate leaders provided the computers and network equipment at a considerable savings to the project. Each lab is a state-of-the-art facility with air-conditioning, carpeting, special computer tables, computer projection screens, and on-site technical support. Student and teacher enthusiasm toward the project has been gratifying and quantitative results are currently being evaluated for both attitude, skills, and state proficiency tests.

1994-12-31

137

Characterization of surface defects after flanging of metallic sheets  

British Library Electronic Table of Contents (United Kingdom)

This paper deals with surface defects of automobile outer panels, which alter significantly the vehicle quality. Such defects occur during springback, after forming or flanging steps, and are characterized by concave depression of small amplitude over the convex shape of the part. The aim of this work is to reproduce at the laboratory scale a surface defect that occurs after flanging on a geometry similar to a door upper corner. A dedicated device has been designed in order to generate small size surface defects during flanging of metallic thin sheets. The outer surface of the sample was digitalized and the spatial geometry of the defect was evaluated from curvature change along 2D profiles. This study shows that the flanging height does not influence significantly the surface defect geome...

2011-01-01

138

Case study: Accelerated schedule for MULTI LIMS installation  

Energy Technology Data Exchange (ETDEWEB)

This presentation focuses on the steps taken by the Westinghouse Hanford Company to meet an accelerated schedule for configuration and implementation of the MULTI LIMS in a multiple laboratory environment. The Westinghouse Hanford Company purchased the MULTI LIMS Laboratory Information Management System in August, 1993. Hardware delivery began in October, 1993. Less than four months later, the initial configuration was released for use in two Westinghouse Hanford Company laboratories. Several major obstacles were overcome during implementation. These include information gathering for base table loading, user training, acceptance of the new system by users of a legacy system, and hardware configuration issues. In summary, steps needed to be taken to meet the accelerated implementation schedule of the MULTI LIMS at the Hanford Site. The obstacles faced were overcome through the in-depth knowledge and help of the vendor and the dedication and drive of the technical ...

1994-05-01

139

Binary pseudo-random grating as a standard test surface formeasurement of modulation transfer function of interferometricmicroscopes  

Energy Technology Data Exchange (ETDEWEB)

The task of designing high performance X-ray optical systemsrequires the development of sophisticated X-ray scattering calculationsbased on rigorous information about the optics. One of the mostinsightful approaches to these calculations is based on the powerspectral density (PSD) distribution of the surface height. The majorproblem of measurement of a PSD distribution with an interferometricand/or atomic force microscope arises due to the unknown ModulationTransfer Function (MTF) of the instruments. The MTF characterizes theperturbation of the PSD distribution at higher spatial frequencies. Here,we describe a new method and dedicated test surfaces for calibration ofthe MTF of a microscope. The method is based on use of a speciallydesigned Binary Pseudo-random (BPR) grating. Comparison of atheoretically calculated PSD spectrum of a BPR grating with a spectrummeasured with the grating provides the desired calibration of theinstrumental MTF. The theoretical ...

2007-07-25

140

A Unified Model for Evolutionary Multiobjective Optimization and its Implementation in a General Purpose Software Framework: ParadisEO-MOEO  

CERN Document Server

This paper gives a concise overview of evolutionary algorithms for multiobjective optimization. A substantial number of evolutionary computation methods for multiobjective problem solving has been proposed so far, and an attempt of unifying existing approaches is here presented. Based on a fine-grained decomposition and following the main issues of fitness assignment, diversity preservation and elitism, a conceptual global model is proposed and is validated by regarding a number of state-of-the-art algorithms as simple variants of the same structure. The presented model is then incorporated into a general-purpose software framework dedicated to the design and the implementation of evolutionary multiobjective optimization techniques: ParadisEO-MOEO. This package has proven its validity and flexibility by enabling the resolution of many real-world and hard multiobjective optimization problems.

2009-01-01

141

A Network Coding Approach to Loss Tomography  

CERN Document Server

Network tomography aims at inferring internal network characteristics based on measurements at the edge of the network. In loss tomography, in particular, the characteristic of interest is the loss rate of individual links. There is a significant body of work dedicated to this problem using multicast and/or unicast end-to-end probes. Independently, recent advances in network coding have shown that there are several advantages from allowing intermediate nodes to process and combine, in addition to just forward, packets. In this paper, we pose the problem of loss tomography in networks that have network coding capabilities. We design a framework for estimating link loss rates, which leverages network coding capabilities and we show that it improves several aspects of tomography, including the identifiability of links, the tradeoff between estimation accuracy and bandwidth efficiency, and the complexity of probe path selection. We discuss the cases of inferring: the ...

2010-01-01

142

Visualization of disturbed flow with spin-echo and cine MR imaging  

International Nuclear Information System (INIS)

MR images of steady and pulsatile disturbed flow, obtained with use of flow-compensated spin-echo (SE) and cine pulse sequences, revealed excellent flow visualization in three dimensions. Phantoms, built from molds of actual blood vessels, reproduced laminar, disturbed, or turbulent flow. Video recording (VR), performed under conditions equivalent to those of the MR experiments, showed separation zones identical to those seen on SE images. Pulsatile flow studies showed complex patterns of vortical flow on cine images and VR. Varying pulse sequence details changed contrast but not flow patterns. The validation of MR observations by VR has implications for clinical cine imaging and low abnormal signals observed on MR angiograms.

143

Tracheal cross-sectional area in children: CT determination  

Energy Technology Data Exchange (ETDEWEB)

A computer method that calculates tracheal cross-sectional area by compensating for partial volume averaging was developed and validated in a study with phantoms. The program was then used to determine the tracheal cross-sectional area of 30 normal children who ranged in age from four months to 18 years. CT-derived cross sections were correlated with age, height, weight, and body-surface area, and they were compared with findings of published clinical and post-mortem studies. CT cross-sectional areas ranged from 20 to 275 mm/sup 2/, varied by as much as 22% at the three different tracheal levels studied, and appeared to correlate most closely with body height. CT-derived tracheal cross-sectional areas are quite similar to those in published reports of postmortem and clinical studies. Measurements of tracheal cross section by CT may prove useful in quantitating tracheal compromise by intrinsic or extrinsic causes.

1983-10-01

144

Total skin electron beam therapy in mycosis fungoides. Evaluation of a technique for deceleration of electron beam energy and clinical study  

Energy Technology Data Exchange (ETDEWEB)

The studies using phantoms confirmed that the reduction of electron beam energy and minimization of X-ray contamination could be achieved when electron beam was interposed by an acrylic plate placed 20 cm anterior to a patient. Four patients of mycosis fungoides were treated with 8 MeV electron beam of a linear accelerator at UOEH Hospital from October 1981 to December 1986. Two of them were treated with this technique by placing 2 cm thick acrylic plate anterior to the patients and satisfactory results were obtained. Cutaneous lesions subsided remarkably with the dosage of 2000 cGy given in 2 months. Leucopenia due to bone marrow suppression was mild and the patients tolerated the treatment well.

1988-08-01

145

Total skin electron beam therapy in mycosis fungoides  

International Nuclear Information System (INIS)

The studies using phantoms confirmed that the reduction of electron beam energy and minimization of X-ray contamination could be achieved when electron beam was interposed by an acrylic plate placed 20 cm anterior to a patient. Four patients of mycosis fungoides were treated with 8 MeV electron beam of a linear accelerator at UOEH Hospital from October 1981 to December 1986. Two of them were treated with this technique by placing 2 cm thick acrylic plate anterior to the patients and satisfactory results were obtained. Cutaneous lesions subsided remarkably with the dosage of 2000 cGy given in 2 months. Leucopenia due to bone marrow suppression was mild and the patients tolerated the treatment well. (author).

146

The effect of patient positioning aids on PET quantification in PET/MR imaging  

British Library Electronic Table of Contents (United Kingdom)

Objectives Clinical PET/MR requires the use of patient positioning aids to immobilize and support patients for the duration of the combined examination. Ancillary immobilization devices contribute to overall attenuation of the PET signal, but are not detected with conventional MR sequences and, hence, are ignored in standard MR-based attenuation correction (MR-AC). We report on the quantitative effect of not accounting for the attenuation of patient positioning aids in combined PET/MR imaging. Methods We used phantom and patient data acquired with positioning aids on a PET/CT scanner (Biograph 16, HI-REZ) to mimic PET/MR imaging conditions. Reference CT-based attenuation maps were generated from measured (original) CT transmission images (origCT-AC). We also created MR-like attenuation map...

2011-01-01

147

Somatic radiation risk in different mammography techniques  

International Nuclear Information System (INIS)

By measuring organ doses with TLD at an Alderson-Rando-phantom it was tested to evaluate the somatic risk for mammographies. Similarly as the genetic risk can be expressed by the genetic significant dose, the somatic risk can be expressed by the somatic significant dose index. The measurement results of the mammography show a large deviation of almost one power of ten with dependence of the chosen technique. In conventional xeroradiography and recording technique with foilless film the somatic radiation risk is the highest. By using amplifying foils in combination with high-sensitive films it is relatively small. Unfortunately the magnitude of the somatic risk in the different mammography techniques is in the ratio reciprocal to the corresponding image quality. At the time being the most favourable technique is mammography with a soft rastering method, although the xeromammography with additional high aluminium-filtering is a further alternative with respect to ...

1981-01-01

148

Somatic and genetic radiation exposure of the patient in digital subtraction angiography (DSA)  

International Nuclear Information System (INIS)

The somatic and genetic radiation exposure of patients undergoing Digital Subtraction Angiography (DSA) and traditional Film Arteriography (FA) of cranial, cervical, thoracic and abdominal vascular territories are compared. The radiation doses absorbed within the critical organs - red bone marrow, lung, thyroid gland and female breast - and in the gonads were measured using an anthropomorphic Alderson phantom. A Somatic Dose Index was calculated in order to estimate the somatic radiation risk. The somatic radiation exposure depends upon the location of the critical organs with respect to the entrance site of the x-ray beam, and can be reduced by an appropriate choice of the angiographic projection. Under this condition, the radiation exposure of the patient during DSA can be lower than during FA. For renal DSA an a.p. projection, the use of an abdominal compression device and careful caudal shielding of the field are advocated. (orig.).

1986-01-01

149

Sex Differences in Pain and Psychological Functioning in Persons With Limb Loss  

British Library Electronic Table of Contents (United Kingdom)

Sex differences in pain are frequently reported in the literature. However, less is known about possible sex differences in the experience of pain secondary to a disability. The current study explored these issues in persons with limb loss (n = 335, 72% men) who were recruited as part of a postal survey. Participants provided ratings of phantom limb pain (PLP), residual limb pain (RLP), and general pain intensity. Participants also completed measures of pain-related interference, catastrophizing, coping, and beliefs. Results indicated that a greater proportion of males than females (86% vs 77%, respectively) reported the presence of PLP; however, this difference was no longer prominent when cause of limb loss was controlled. No sex differences were found in the presence of RLP, or in avera...

2010-01-01

150

Radioexposure of children in cranial examinations with new-generation CT equipment  

Energy Technology Data Exchange (ETDEWEB)

Using phantoms of children simulating a child of 6 months of age and another one aged 6 years, the authors measured the amount of radioexposure of the lens of the eye, the thyroid and of the gonads. The two computer tomographs Somatom SF and Tomoscan 300 under examination, produced radiodoses of comparable magnitudes. Both devices allow additional examination techniques of particularly high economy. It was found that in cranial CT the exposure of the lens to radiation is generally below 1 R if the orbitae are not situated in the plane of section. If a distance of 2-3 cm is maintained from the orbitae, the dose remains below 0.5 R. Protecting the gonads is meaningful in a 6-year-old boy, whereas covering-up of the thyroid reduced the dose only slightly.

1983-04-01

151

Radiation exposure to patients during hepatic interventional procedure  

International Nuclear Information System (INIS)

Objective: To investigate the X-ray radiation dose patients dealt with the hepatic intervention. Methods: Thermoluminescence and tissue-equivalent anthropomorphic phantom were used to measure the X-ray radiation dose in patients dealt with the hepatic intervention in 85 patients. Results: The peak skin dose in the patients who accepted hepatic intervention was from 179.95 to 1759.00 mGy, effective dose approached 29.22 mSv (male), 29.27 mSv (female). Conclusion: Hepatic intervention is now regarded as an important therapeutic method for liver cancer. However, the patients were exposed to too much X-ray radiation during interventional procedures. Some more effective protection should be taken to decrease the X-ray radiation dose accepted by patients. (authors)

2005-05-01

152

Quantitative bone scintigraphy. A methodological evaluation in prostate cancer  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluate a simple method for quantification of focal activity in bone scintigraphy (BS). Material and methods: The gamma camera was calibrated using a phantom. Quantitative bone scintigraphy (QBS) was performed on 11 men recently diagnosed with prostate cancer (PCa), for whom routine BS showed involvement of the skeleton. Following endocrine therapy for 4 to 8 months, a second QBS was performed. Changes in QBS values were then compared to changes in serum levels of prostate-specific antigen (PSA). Results: PSA response indicating regression of PCa was accompanied by a decrease in the QBS value in 8 of the 11 patients. The overall mean error of the QBS values was 15%. conclusion: QBS according to this method is a relatively simple procedure that might contribute to objective evaluation of therapeutic effects in skeletal metastases, although its validity must be tested in a larger clinical material.

2000-03-01

153

Quantitative bone scintigraphy. A methodological evaluation in prostate cancer  

International Nuclear Information System (INIS)

Purpose: To evaluate a simple method for quantification of focal activity in bone scintigraphy (BS). Material and methods: The gamma camera was calibrated using a phantom. Quantitative bone scintigraphy (QBS) was performed on 11 men recently diagnosed with prostate cancer (PCa), for whom routine BS showed involvement of the skeleton. Following endocrine therapy for 4 to 8 months, a second QBS was performed. Changes in QBS values were then compared to changes in serum levels of prostate-specific antigen (PSA). Results: PSA response indicating regression of PCa was accompanied by a decrease in the QBS value in 8 of the 11 patients. The overall mean error of the QBS values was 15%. conclusion: QBS according to this method is a relatively simple procedure that might contribute to objective evaluation of therapeutic effects in skeletal metastases, although its validity must be tested in a larger clinical material

2000-03-01

154

Quantitative Computed Tomography (QCT) of vertebral spongiosa. Evaluation of a possible method for managment of postmenopausal osteoporosis (PMO)  

International Nuclear Information System (INIS)

A Quantitative Computed Tomography (QCT) method, simplifying the well-known technique proposed by Genant (1982) and applied to a standard third generation whole body CT scanner is described. This technique was applied in the measurement of the trabecular bone which has high sensitivity for metabolic changes. The BMC (Bone Mineral Content) measured in different groups of subjects (healthy postmenopausal patients versus women with postmenopausal osteoporosis) showed a highly significant difference (p<0.001). The precision of repositioning (coefficient of variation 1.8% to 2.3%, obtained in healty male patients) and the good, linear relationship computed from the phantom values, minimize measurement errors. Since this method is quickly applied and involves low-dose radiation-exposure, it could be introduced in the clinical study of metabolic bone diseases.

1987-01-01

155

Preparation and dosimetry of radiotherapeutic particles for arthropaties; Preparacion y dosimetria de particulas radioterapeuticas para artropatias  

Energy Technology Data Exchange (ETDEWEB)

It was developed a new formulation of macro aggregates of Samarium 153 ({sup 153} Sm-MH) for the arthropaties treatment. The radio pharmaceutic was prepared by reaction of Samarium 153 chloride (SmCl{sub 3}) in aqueous environment with sodium boron hydride in NaOH 0.5 N. The microscopic analysis shown that the particles have an average size of 4% m (range 1-14 {mu} m). The velocity of sedimentation was 0.008 cm/min with high stability in vitro in human serum. The biological studies in healthy rabbits, shown that the complex is retained inside the articulation still eight days after of the administration of the radiopharmaceutical. Likewise, it is presented the data of absorbed dose in the different target organs, which was determined by thermoluminescent dosimetry (TLD) through the use of a REMCAL phantom (radiation equivalent manikin calibration). (Author)

1999-07-01

156

Preamputation Pain and Acute Pain Predict Chronic Pain After Lower Extremity Amputation  

British Library Electronic Table of Contents (United Kingdom)

Although previous research suggests that preamputation pain is a risk factor for pain after amputation, little is known about the association between acute postsurgical pain and chronic amputation-related pain. The current prospective study examined the associations of preamputation pain and acute postamputation pain with chronic amputation-related pain. The sample consisted of patients with lower limb amputation (N = 57) who provided both preamputation and postamputation data during a 2-year study period. Preamputation pain intensity and duration were assessed before amputation; acute phantom limb pain (PLP) and residual limb pain (RLP) intensity were assessed on postsurgical days 4 and 5. Acute PLP intensity was the only significant independent predictor of chronic PLP intensity at 6 and...

2007-01-01

157

Portal localization images using computed radiography for high-energy electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

Portal localization images for high-energy electron beam therapy are necessary to confirm the treatment field by comparing them with a simulation image obtained before treatment or portal verification images after treatment. In this study, portal localization images were acquired using the computed radiography (CR) system and bremsstrahlung X-rays generated in the electron beam irradiations. All images obtained with phantom and the irradiations of in the electron energy of 8, 10, 12 and 15 MeV were feasible for clinical use. The CR system used in this study included general diagnostic imaging cassette and storage phosphor plate, but none of other special devices. The system can usually supply portal localization images, which maintains the quality assurance of high-energy electron beam therapy. (author)

2002-09-01

158

Photon beam modelling with Pinnacle3 Treatment Planning System for a Rokus M Co-60 Machine  

International Nuclear Information System (INIS)

The basic relationships of the convolution/superposition dose calculation technique are reviewed, and a modelling technique that can be used for obtaining a satisfactory beam model for a commercially available convolution/superposition-based treatment planning system is described. A fluence energy spectrum for a Co-60 treatment machine obtained from a Monte Carlo simulation was used for modelling the fluence spectrum for a Rokus M machine. In order to achieve this model we measured the depth dose distribution and the dose profiles with a Wellhofer dosimetry system. The primary fluence was iteratively modelled by comparing the computed depth dose curves and beam profiles with the depth dose curves and crossbeam profiles measured in a water phantom. The objective of beam modelling is to build a model of the primary fluence that the patient is exposed to, which can then be used for the calculation of the dose deposited in the patient. (authors)

159

Photoacoustic imaging using an ultrasonic Fresnel zone plate transducer  

International Nuclear Information System (INIS)

A photoacoustic (PA) imaging system based on an ultrasonic Fresnel zone plate (FZP) transducer is developed for the purpose of imaging biological tissue. This FZP transducer has a two-zone negative zone plate piezoelectric material pattern, and an optical fibre is integrated with the transducer on the symmetric axis of the zone plates to deliver laser pulses to the sample. The focal characteristic of the FZP transducer is analysed by theoretical prediction and experimental measurement, and the measured results are in good agreement with the predicted results. The limited-field back-projection deconvolution algorithm combined with the coherence-factor weighting technique is used to reconstruct the optical absorption distribution. The experiments were performed with phantoms and the blood vessels of chicken embryo chorioallantoic membrane. The results demonstrate that PA imaging using the FZP transducer has the ability to image biological tissue and has potential ...

2008-05-07

160

Organ doses received by atomic bomb survivors during radiological examinations at the Radiation Effects Research Foundation  

Energy Technology Data Exchange (ETDEWEB)

When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).

1991-08-01

161

Organ doses received by atomic bomb survivors during radiological examinations at the Radiation Effects Research Foundation  

International Nuclear Information System (INIS)

When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).

1991-01-01

162

Minimizing radiation dose to patient and staff during fluoroscopic, nasoenteral tube insertions  

Energy Technology Data Exchange (ETDEWEB)

Since the fluoroscopic image during nasoenteral tube placements is used for guidance and not for diagnosis, a lower contrast image with increased quantum mottle can be easily tolerated. The three methods to reduce the radiation dose rate investigated consisted of removing camera from the image intensifier output phosphor, and setting the fluoroscopic mA to the minimum value so that the kVp could be maximized. Fluoroscopic frozen video frames of a clinical tube insertion comparing the images with and without the dose-saving techniques are presented. Measurements of the radiation dose rates using a Plexiglas phantom show that the dose for patient and staff during fluoroscopic-guided nasoenteral tube placements can be reduced by over a factor of 10 without significantly adversely affecting the actual placement procedure. (author).

1992-02-01

163

Efficiency of a lead-containing tie for radiation protection of the thyroid gland  

Energy Technology Data Exchange (ETDEWEB)

During fluoroscopy the examiner is usually protected by a radiation-reducing body shield, leaving the thyroid unprotected. The fact that the thyroid is located in a region of the neck usually covered by the shirt collar led to the idea of designing a tie with lead core, providing easy and ''decorative'' reduction of the radiation dose. Sonographic examinations were carried out in 20 volunteers (10 men, 10 women) to determine the size of the gland and its coverage by such a tie. The reduction of the surface and organ dose was assessed using film dosimetry with scattered radiation, the body of the examiner being simulated by an Alderson phantom. On average 88% of the thyroid gland surface area was covered. Surface dose was reduced to 1%, and organ dose to 10% of the value without the protection tie. (Author).

1992-11-01

164

Efficiency of a lead-containing tie for radiation protection of the thyroid gland  

International Nuclear Information System (INIS)

During fluoroscopy the examiner is usually protected by a radiation-reducing body shield, leaving the thyroid unprotected. The fact that the thyroid is located in a region of the neck usually covered by the shirt collar led to the idea of designing a tie with lead core, providing easy and ''decorative'' reduction of the radiation dose. Sonographic examinations were carried out in 20 volunteers (10 men, 10 women) to determine the size of the gland and its coverage by such a tie. The reduction of the surface and organ dose was assessed using film dosimetry with scattered radiation, the body of the examiner being simulated by an Alderson phantom. On average 88% of the thyroid gland surface area was covered. Surface dose was reduced to 1%, and organ dose to 10% of the value without the protection tie. (Author).

165

Digital radiography of pulmonary abnormalities using Fuji computed radiography (FCR)  

Energy Technology Data Exchange (ETDEWEB)

Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best practical conditions were determined. (author).

1991-12-01

166

Digital radiography of pulmonary abnormalities using Fuji computed radiography (FCR)  

International Nuclear Information System (INIS)

Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best practical conditions were determined. (author).

1991-01-01

167

Affective Distress and Amputation-Related Pain Among Older Men with Long-Term, Traumatic Limb Amputations  

British Library Electronic Table of Contents (United Kingdom)

Psychological distress and postamputation pain were investigated in a sample of 582 males with long-term limb amputations (mean time since amputation 639.3 months, standard deviation 166.1; range 240-784 months). Prevalence of significant depressive symptoms (Hospital Anxiety and Depression Scale [HADS]-D score?8) was 32.0%, and 34.0% of respondents met the screening criterion for clinical anxiety (HADS-A score?8). Nearly one quarter (24.6%) of respondents reported significant post-traumatic psychological stress symptoms (Impact of Event Scale scores?35). In total, 87.8% experienced either phantom or residual limb pain. Affective distress scores differed according to the respondents' type of pain experience. Respondents who experienced residual limb pain reported significantly hig...

2006-01-01

168

A novel method for quantifying scanner instability in fMRI  

British Library Electronic Table of Contents (United Kingdom)

Abstract A method was developed to quantify the effect of scanner instability on functional MRI data by comparing the instability noise to endogenous noise present when scanning a human. The instability noise was computed from agar phantom data collected with two flip angles, allowing for a separation of the instability from the background noise. This method was used on human data collected at four 3 T scanners, allowing the physiological noise level to be extracted from the data. In a -well-operating- scanner, the instability noise is generally less than 10% of physiological noise in white matter and only about 2% of physiological noise in cortex. This indicates that instability in a well-operating scanner adds very little noise to functional MRI results. This new method allows researcher...

2011-01-01

169

A compensating method of an imaging plate response to clinical proton beams  

Energy Technology Data Exchange (ETDEWEB)

For charged particle irradiations, the response of an imaging plate (IP) changes around the Bragg peak. Therefore, an appropriate compensation is necessary for the evaluation of dose distribution formed by charged particles such as protons. In this paper, the response of IPs to clinical proton beams is investigated. An experimentally-obtained depth-dose distribution (an ordinary Bragg curve) by a silicon semiconductor detector (SSD) is employed to evaluate the compensation factors as a function of proton penetrating depth, i.e. residual range. A typical dose distribution in a water phantom formed by an L-shaped bolus is measured by IPs and corrected by using the information of those compensation factors; the residual proton range is successfully calculated by the pencil beam algorithm at an arbitrary point. The results show a good agreement with the measurements by the SSD within the rms error of 3.0%.

2002-04-01

170

HVDC power cable crossing Kii channel. Advanced technology to lay the submarine cable in two days; Kii suido wo yokogiru denryoku cable. Kaitei fusetsu wo futsuka de konasu shin`ei sochi  

Energy Technology Data Exchange (ETDEWEB)

Four HVDC (high voltage DC) {+-} 250kV submarine OF (oil-filled) cables are to be installed each capable of 1.4-million kW for one dipole channel and two returns for forwarding to Yura Switchyard a part of the power to be generated by a Tachibanawan coal-fired power plant to open in 2000. The first cable is now being laid. They are to cover a distance of 48km on the sea bottom, and their 190mm diameter is the largest in the world and this decreases the required number of cables for a reduction in the construction cost. The installation is executed by use of a dedicated cable laying ship loaded with cables. The ship is equipped with five thruster screws by adjusting which a cable is fed into the sea and laid on the bottom with high positional accuracy in all directions, and with a 10m-accurate DPS (Dynamic Positioning System) besides GPS (Global Positioning System). Operating on the sea bottom is a simultaneous laying/burying machine which buries the cable 2-3m deep ...

1998-07-01

171

Emissions results for dedicated propane Chrysler minivans: the 1996 propane vehicle challenge  

Energy Technology Data Exchange (ETDEWEB)

The U.S. Department of Energy (US DOE), through Argonne National Laboratory, and in cooperation with Natural Resources-Canada and Chrysler Canada, sponsored and organized the 1996 Propane Vehicle Challenge (PVC). For this competition , 13 university teams from North America each received a stock Chrysler minivan to be converted to dedicated propane operation while maintaining maximum production feasibility. The converted vehicles were tested for performance (driveability, cold- and hot-start, acceleration, range, and fuel economy) and exhaust emissions. Of the 13 entries for the 1996 PVC, 10 completed all of the events scheduled, including the emissions test. The schools used a variety of fuel-management, fuel-phase and engine-control strategies, but their strategies can be summarized as three main types: liquid fuel-injection, gaseous fuel-injection, and gaseous carburetor. The converted vehicles performed similarly to the gasoline minivan. The University of ...

1997-02-01

172

Building a Construction Curriculum for Your School District  

Science.gov (United States)

Embracing the notion of going green, an affluent school district in Pennsylvania spent $83 million as part of the high school's renovation and expansion project. The three-level addition is now equipped with self-dimming lights, energy-efficient windows, a rooftop solar water heater, and a geothermal cooling and heating system. As a bonus for going green, the school district received a $250,000 grant from the Pennsylvania Department of Environmental Protection. The district used that money to create an information center in the lobby of the building where a touch-screen computer provides students, staff, and visitors with data related to the operation of the school's energy-efficient water and electrical systems. The system will graphically depict utility use over the course of a year. The monitoring system and touch-screen computer can turn this school into a living lab, with science, math, and economics teachers using the data as teaching tools within classrooms. Teachers can also ...

2010-06-01

173

Using a photon phase-space source for convolution/superposition dose calculations in radiation therapy  

International Nuclear Information System (INIS)

For a given linac design, the dosimetric characteristics of a photon beam are determined uniquely by the energy and radial distributions of the electron beam striking the x-ray target. However, in the usual commissioning of a beam from measured data, a large number of variables can be independently tuned, making it difficult to derive a unique and self-consistent beam model. For example, the measured dosimetric penumbra in water may be attributed in various proportions to the lateral secondary electron range, the focal spot size and the transmission through the tips of a non-divergent collimator; the head-scatter component in the tails of the transverse profiles may not be easy to resolve from phantom scatter and head leakage; and the head-scatter tails corresponding to a certain extra-focal source model may not agree self-consistently with in-air output factors measured on the central axis. To reduce the number of adjustable variables in beam modelling, we replace ...

2005-09-07

174

Spectral sensitivity study of dose distributions for a commercial convolution/superposition algorithm  

International Nuclear Information System (INIS)

The focus of this study is to validate whether the sensitivity of dose distribution following the interface of different media can be used to distinguish between small variations of photon energy spectra in the context of the convolution/superposition algorithm in the polyenergetic implementation (Philips Pinnacle"3, ADAC Laboratories, Milpitas, CA). Calculations were performed in homogeneous water and heterogeneous lung/water phantoms. Spectra were generated, in which the weights of the low-, medium- and high-energy components were adjusted sequentially. The heterogeneity correction factor CF_l_u_n_g, the D_2_0/D_1_0 ratio for homogeneous water and logarithmic derivative in buildup region LD_b_u_i_l_d_u_p were assessed for their relative ability to discriminate between different spectra for various field sizes. In accordance with another study (Charland et al 2004), the superior discrimination ability of the CF_l_u_n_g and LD_b_u_i_l_d_u_p tests over the ...

2004-09-21

175

Pulmonary nodule detection of chest phantom with CRT images; Comparison with conventional radiography (film-screen system) and FCR hardcopy  

Energy Technology Data Exchange (ETDEWEB)

Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided into four parts and displayed four images as a subsidiary diagnosis. The upper two images were displayed ...

1989-08-01

176

Pulmonary nodule detection of chest phantom with CRT images  

International Nuclear Information System (INIS)

Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided into four parts and displayed four images as a subsidiary diagnosis. The upper two images were displayed ...

1989-01-01

177

Monte Carlo evaluation of the AAA treatment planning algorithm in a heterogeneous multilayer phantom and IMRT clinical treatments for an Elekta SL25 linear accelerator  

International Nuclear Information System (INIS)

The Anisotropic Analytical Algorithm (AAA) is a new pencil beam convolution/superposition algorithm proposed by Varian for photon dose calculations. The configuration of AAA depends on linear accelerator design and specifications. The purpose of this study was to investigate the accuracy of AAA for an Elekta SL25 linear accelerator for small fields and intensity modulated radiation therapy (IMRT) treatments in inhomogeneous media. The accuracy of AAA was evaluated in two studies. First, AAA was compared both with Monte Carlo (MC) and the measurements in an inhomogeneous phantom simulating lung equivalent tissues and bone ribs. The algorithm was tested under lateral electronic disequilibrium conditions, using small fields (2x2 cm"2). Good agreement was generally achieved for depth dose and profiles, with deviations generally below 3% in lung inhomogeneities and below 5% at interfaces. However, the effects of attenuation and scattering close to the bone ribs were not ...

2007-05-01

178

Maximum imaging depth of two-photon autofluorescence microscopy in epithelial tissues  

Science.gov (United States)

Endogenous fluorescence provides morphological, spectral, and lifetime contrast that can indicate disease states in tissues. Previous studies have demonstrated that two-photon autofluorescence microscopy (2PAM) can be used for noninvasive, three-dimensional imaging of epithelial tissues down to approximately 150 ?m beneath the skin surface. We report ex-vivo 2PAM images of epithelial tissue from a human tongue biopsy down to 370 ?m below the surface. At greater than 320 ?m deep, the fluorescence generated outside the focal volume degrades the image contrast to below one. We demonstrate that these imaging depths can be reached with 160 mW of laser power (2-nJ per pulse) from a conventional 80-MHz repetition rate ultrafast laser oscillator. To better understand the maximum imaging depths that we can achieve in epithelial tissues, we studied image contrast as a function of depth in tissue phantoms with a range of relevant optical properties. The ...

2011-02-01

179

Feasibility of delivering grid therapy using a multileaf collimator  

International Nuclear Information System (INIS)

The feasibility of using a multileaf collimator (MLC) for grid therapy is demonstrated in this study. Grids with the projected field openings of 10 mmx10 mm and 5 mmx5 mm were created using multiple MLC-shaped fields. The deposited doses were measured with films at different depths in a solid water phantom and compared to those of Cerrobend grid collimators of similar hole sizes and hole separations. At the depth of maximum dose (d_m_a_x), the valley-to-peak dose ratios of the MLC grids were found to be about 11% and 19% for the respective 10 mmx10 mm and 5 mmx5 mm grid openings, and those of the corresponding grid blocks were about 15% and 20%. To quantify the dose contributed by transmission in the blocked areas due to the limited leaf thickness, Monte Carlo simulations (based on convolution/superposition method) were performed to calculate the doses in the solid water phantom using an ideal MLC with no leakage and perfect divergence in both ...

2006-01-01

180

Dosimetric evaluation of multi-pattern spatially fractionated radiation therapy using a multi-leaf collimator and collapsed cone convolution superposition dose calculation algorithm  

International Nuclear Information System (INIS)

Purpose: In this paper, we present an alternative to the originally proposed technique for the delivery of spatially fractionated radiation therapy (GRID) using multi-leaf collimator (MLC) shaped fields. We employ the MLC to deliver various pattern GRID treatments to large solid tumors and dosimetrically characterize the GRID fields. Methods and materials: The GRID fields were created with different open to blocked area ratios and with variable separation between the openings using a MLC. GRID designs were introduced into the Pinnacle"3 treatment planning system, and the dose was calculated in a water phantom. Ionization chamber and film measurements using both Kodak EDR2 and Gafchromic EBT film were performed in a SolidWater phantom to determine the relative output of each GRID design as well as its spatial dosimetric characteristics. Results: Agreement within 5.0% was observed between the Pinnacle"3 predicted dose distributions and the ...

2009-10-01

181

Digital subtraction angiography (DSA) using Fuji computed radiography (FCR)  

International Nuclear Information System (INIS)

A vessel phantom suitable for evaluation of spatial and contrast resolution of FCRDSA (Fuji Computed Radiography, digital subtraction angiography) has been developed and used for determining resolution. The effects of iodine concentration, low dose exposure, and acryl thickness on the resolution were evaluated in FCRDSA, and FCRDSA images were compared with film substraction with use of this phantom. It has been proven that limitation of resolution of FCRDSA was 5 % 1 mm and about 1/4 dose exposure compared with conventional film exposure was clinically acceptable. Dye dilution method was useful to determine a program of IVDSA with imaging plate. It has been proven that time to appearance and time to peak of time-concentration curve of dye dilution method closely correlate to time to appropriate image of DSA in the neck, the chest, and the abdomen. 106 cases of IVDSA and 130 cases of IADSA using FCR in Tohoku University Hospital from January ...

1984-12-01

182

Accuracy of the convolution/superposition dose calculation algorithm at the condition of electron disequilibrium  

International Nuclear Information System (INIS)

Using Monte Carlo simulation and the convolution/superposition algorithm, this work examines percent depth dose curves of the central axis in an acrylic phantom (20x20x20 cm"3) with variously sized air cavities (20x20x1.0, 20x20x2.0, 20x20x3.0, 20x20x4.0 and 20x20x4.95 cm"3 for study of longitudinal electron disequilibrium (ED) and 3.6x3.6x4.95, 4.5x4.5x4.95, 5.4x5.4x4.95 and 20x20x4.95 cm"3 for study of lateral ED). Radiochromic film samples are also measured to verify the Monte Carlo results. The Monte Carlo simulation is performed using OMEGA/BEAM and DOSXYZ codes, and the convolution/superposition calculation relies on an ADAC commercial treatment planning system. Underestimating the dose kernel expansion leads to overestimating the dose of what was found in the air cavity of ED using the convolution/superposition algorithm. Consequently, the dose in the rebuild-up region is influenced. The influenced region is on the acrylic phantom ...

2002-12-01

183

Accuracy of calculations for stereotactic radiotherapy of the lung. Comparison of dose calculation algorithms  

International Nuclear Information System (INIS)

The purpose of this study is to evaluate the accuracy of dose calculations by three algorithms. Depth dose, OPF (Output Factor) and dose profiles were measured in a heterogeneous phantom. These values were also calculated by three algorithms of the Batho power law (BPL), Equivalent-Tissue Air Ratio (ETAR) and Convolution superposition (CS). The data were obtained for 4, 6 and 10 MV photon beams with a linear accelerator (Varian 21EX). Field size ranged from 3 x 3 cm"2 to 10 x 10 cm"2. Dose profiles of beam penumbra were also measured by a 0.125 ml ionization chamber at the point of 8, 13 and 18 cm from the surface of the phantom at intervals of 1 mm. Differences between measured and calculated depth doses were within 2% in BPL and CS, but depth doses were overestimated in ETAR. OPFs were also overestimated with the error of more than 4% in ETAR. Absorbed dose calculated by CS were in agreement with the values measured by the ionization chamber. ...

2004-12-01

184

A cooled water-irrigated intraesophageal balloon to prevent thermal injury during cardiac ablation: experimental study based on an agar phantom  

Energy Technology Data Exchange (ETDEWEB)

A great deal of current research is directed to finding a way to minimize thermal injury in the esophagus during radiofrequency catheter ablation of the atrium. A recent clinical study employing a cooling intraesophageal balloon reported a reduction of the temperature in the esophageal lumen. However, it could not be determined whether the deeper muscular layer of the esophagus was cooled enough to prevent injury. We built a model based on an agar phantom in order to experimentally study the thermal behavior of this balloon by measuring the temperature not only on the balloon, but also at a hypothetical point between the esophageal lumen and myocardium (2 mm distant). Controlled temperature (55 {sup 0}C) ablations were conducted for 120 s. The results showed that (1) the cooling balloon provides a reduction in the final temperature reached, both on the balloon surface and at a distance of 2 mm; (2) coolant temperature has a significant effect on the temperature ...

2008-02-21

185

ETE-EVAL: a methodology for D and D cost estimation  

International Nuclear Information System (INIS)

In compliance with Article 20 of the sustainable radioactive materials and waste management act dated 28 June 2006, the CEA and AREVA are required every three years to revise the cost of decommissioning their facilities and to provide the necessary assets by constituting a dedicated fund. For the 2007 revision the CEA used ETE-EVAL V5. Similarly, AREVA reevaluated the cost of decontaminating and dismantling its facilities at La Hague, as the previous estimate in 2004 did not take into account the complete cleanup of all the structural work. ETE-EVAL V5 is a computer application designed to estimate the cost of decontamination and dismantling of basic nuclear installations (INB). It has been qualified by Bureau Veritas and audited. ETE-EVAL V5 has become the official software for cost assessment of CEA civilian and AREVA decommissioning projects. It has been used by the DPAD (Decontamination and Dismantling Projects Department) cost assessment group to estimate the ...

186

Ultra high field magnetic resonance imaging  

International Nuclear Information System (INIS)

Understanding human brain function, brain development and brain dysfunction is one of the great challenges of the twenty first century. Biomedical imaging has now run up against a number of technical constraints that are exposing limits to its potential. In order to overcome the current limits to high-field magnetic resonance cerebral imaging (MRI) and unleash its fullest potential, the Cea has built NeuroSpin, an ultra-high-field neuroimaging facility at its Saclay centre (in the Essonne). NeuroSpin already boasts three fully operational MRI systems. The first is a 3-tesla high-field system and the second is a very-high-field 7-tesla system, both of which are dedicated to clinical studies and investigations in humans, while the third is an ultra-high-field 17.65-tesla system designed for studies on small animals. In 2011, NeuroSpin will be commissioning an 11.7-tesla ultra-high-field system of unprecedented power that is designed for research on human subjects. ...

187

Type Ia supernova science 2010-2020  

CERN Document Server

In the next decade Type Ia supernovae (SNe Ia) will be used to test theories predicting changes in the Dark Energy equation of state with time. Ultimately this requires a dedicated space mission like JDEM. SNe Ia are mature cosmological probes --- their limitations are well characterized, and a path to improvement is clear. Dominant systematic errors include photometric calibration, selection effects, reddening, and population-dependent differences. Building on past lessons, well-controlled new surveys are poised to make strides in these areas: the Palomar Transient Factory, Skymapper, La Silla QUEST, Pan-STARRS, the Dark Energy Survey, LSST, and JDEM. They will obviate historical calibrations and selection biases, and allow comparisons via large subsamples. Some systematics follow from our ignorance of SN Ia progenitors, which there is hope of determining with SN Ia rate studies from 0

2009-01-01

188

Two-phase flow studies  

Energy Technology Data Exchange (ETDEWEB)

The two-phase flow program is directed at understanding the hydrodynamics of two-phase flows. The two-phase flow regime is characterized by a series of flow patterns that are designated as bubble, slug, churn, and annular flow. Churn flow has received very little scientific attention. This lack of attention cannot be justified because calculations predict that the churn flow pattern will exist over a substantial portion of the two-phase flow zone in producing geothermal wells. The University of Houston is experimentally investigating the dynamics of churn flow and is measuring the holdup over the full range of flow space for which churn flow exists. These experiments are being conducted in an air/water vertical two-phase flow loop. Brown University has constructed and is operating a unique two-phase flow research facility specifically designed to address flow problems of relevance to the geothermal industry. An important feature of the facility is that it is ...

1983-12-01

189

Tune resonance phenomena in the SPS and machine protection via fast position interlocking  

Energy Technology Data Exchange (ETDEWEB)

The 6911 m long Super Proton Synchrotron (SPS) at CERN with a peak energy of 450 GeV is at the top of the LHC preaccelerator-complex. Apart from the LHC, the SPS is with the Tevatron the accelerator with the largest stored beam energy of up to 2.5 MJ. The SPS has a known vulnerability to fast equipment failures that led to an uncontrolled loss of a high intensity beam in 2008, which resulted in major damage of a main dipole. The beam loss was caused by a fast tune decrease towards an integer resonance. Simulations and distinct experimental studies provide clear understanding of the beam dynamics at different SPS tune resonances. Diverging closed orbit oscillations, dispersion explosion and increased beta-beating are the driving effects that lead to a complete beam loss in as little as 10 turns (230 {mu}s) after reaching the stop band of the resonance. Dedicated experiments of fast failures of the main power converters reveal that the current interlock systems with ...

2010-07-01

190

Tune resonance phenomena in the SPS and machine protection via fast position interlocking  

International Nuclear Information System (INIS)

The 6911 m long Super Proton Synchrotron (SPS) at CERN with a peak energy of 450 GeV is at the top of the LHC preaccelerator-complex. Apart from the LHC, the SPS is with the Tevatron the accelerator with the largest stored beam energy of up to 2.5 MJ. The SPS has a known vulnerability to fast equipment failures that led to an uncontrolled loss of a high intensity beam in 2008, which resulted in major damage of a main dipole. The beam loss was caused by a fast tune decrease towards an integer resonance. Simulations and distinct experimental studies provide clear understanding of the beam dynamics at different SPS tune resonances. Diverging closed orbit oscillations, dispersion explosion and increased beta-beating are the driving effects that lead to a complete beam loss in as little as 10 turns (230 #mu#s) after reaching the stop band of the resonance. Dedicated experiments of fast failures of the main power converters reveal that the current interlock systems with ...

2010-03-15

191

Truck tactics: dispatch from Vancouver  

Energy Technology Data Exchange (ETDEWEB)

Any mine that uses haultrucks has a dispatching system of some sort, even if it is only a very basic and simple arrangement. The larger, more complex operations have found that, if properly applied, automated computerised dispatching improves the productivity of the equipment as well as improving overall control and reporting. However, not every mine can justify going this far; in these cases a computerised monitoring and reporting system with manual dispatching can still give considerable benefits. Wenco International Mining Systems of Vancouver supplies its computerised system to three different specification levels to suit most open pit mining operations. The article describes the 3 PMCSs (Production Monitoring and Control System) available: PMCS 1000, for monitoring and reporting only; PMCS 2000, for dispatching to maximise production; and PMCS 3000, for dispatching with optimised product quality and production. The major components of the PMCS are: mobile data terminals fitted to ...

1991-11-01

192

Thermoplastic polymer patterning without residual layer by advanced nanoimprinting schemes  

Energy Technology Data Exchange (ETDEWEB)

Nanoimprinting is a fast-growing technique for nanoscale patterning. One of the remaining issues in nanoimprinting is the removal of the residual layer after nanoimprinting. Traditionally the residual layer is removed by an oxygen reactive-ion etching (RIE) step. The need for a vacuum environment and dedicated equipment in this step lowers the throughput and increases the cost of the nanoimprinting process. It also prevents the possibility of patterning isolated functional polymers because oxygen RIE destroys the functional materials. In this work, novel nanoimprinting schemes are developed to nondestructively remove the residual layer in thermal nanoimprinting by solvent developing and dewetting. Combined with a transfer-bonding technique, three-dimensional polymer scaffolds are achieved. The techniques developed here eliminate the RIE step in thermal nanoimprinting and are compatible with roller nanoimprinting for large-scale patterning of polymer micro- or ...

2009-06-17

193

The effects of ventilation, filtration, and outdoor air on the composition of indoor air at a telephone office building  

Energy Technology Data Exchange (ETDEWEB)

Sensors installed at a telephone office building in Neenah, WI, continuously monitor 24 parameters related to the operation of the building's heating, ventilating, and air conditioning (HVAC) system. This data is stored in a dedicated minicomputer and can be retrieved, in various formats, for subsequent analyses. For more than a year, we have measured indoor and outdoor concentrations of both fine and coarse airborne particles, their chemical constituents, and volatile organic compounds at this same location. Using this data, we have examined the composition of the indoor air as it correlates to the composition of the outdoor air and the various HVAC operating parameters. The steady-state indoor concentrations of the particles, particulate constituents, and organic vapors can be explained in the context of a mass balance model. This model can also be used to calculate the rate at which selected chemicals are generated within the building, as well as to ...

1989-01-01

194

The Polytechnique, UQAT, NSERC chair in environment and tailings management; La Chaire Polytechnique, UQAT, CRSNG en environnement et gestion des rejets miniers  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this new industrial chair is to ensure the continuation and development of new research activities in the field of environment protection as it relates to the good management of mine tailings. The mining industry plays a vital role in the economy of a number of regions in both Quebec and Canada and also causes environmental problems due to the generation of liquid, solid, and gaseous wastes. Mine tailings can cause acid mine drainage. This acid mine drainage (AMD) can have detrimental effects on the ecosystems adjoining tailings or waste rock piles. We must remain aware that some of the remedial measures instituted to contain AMD might cause problems due to their possible instability. Despite the fact that instability is a rare occurrence, it can have disastrous effects on the environment as demonstrated in Spain, Guyana, and the Philippines during the last few years. The creation of this chair in environment and tailings management will allow the consolidation of ...

2000-07-01

195

TECHNOLOGY TRANSFER TO U.S. INDEPENDENT OIL AND NATURAL GAS PRODUCERS  

Energy Technology Data Exchange (ETDEWEB)

In pursuing its mission of helping U.S. independent oil and gas producers make timely, informed technology decisions, the Petroleum Technology Transfer Council (PTTC) functions as a cohesive national organization that implements industry's directives through active regional programs. The role of the national headquarters (HQ) organization includes planning and managing the PTTC program, conducting nation-wide technology transfer activities, and implementing a comprehensive communications effort. PTTC relies on 10 Regional Lead Organizations (RLOs) as its main program delivery mechanism to industry. Through its regions, PTTC connects with independent oil and gas producers--through technology workshops, resources centers, websites, newsletters, and other outreach efforts. The organization effectively combines federal, state, and industry funding to achieve important goals for all of these sectors. This integrated funding base, combined with industry volunteers guiding ...

1998-10-31

196

Synchrotron resource of the Howard Hughes Medical Institute  

Energy Technology Data Exchange (ETDEWEB)

The Synchrotron Resource of the Howard Hughes Medical Institute will be dedicated to structural analyses of biological macromolecules, primarily through crystallography. This facility is under construction at the X4 port of the National Synchrotron Light Source at Brookhaven National Laboratory, and it will comprise three beamlines. The first line to be built has been devised to apply the multiwavelength anomalous diffraction method which provides direct estimates for the phases of reflections. The second line will be devoted to rapid and essentially routine diffraction measurements, mainly through the rotation method. These two experimental stations are contained within refrigerated radiation enclosures that will maintain clean environments, narrowly defined constant temperatures, and protection against biohazard at biosafety level BL-2. At the same time as the second line will be developed, the swath center is planned to first serve as a monitor of the white ...

1989-07-01

197

Spamology: A Study of Spam Origins  

Energy Technology Data Exchange (ETDEWEB)

The rise of spam in the last decade has been staggering, with the rate of spam exceeding that of legitimate email. While conjectures exist on how spammers gain access to email addresses to spam, most work in the area of spam containment has either focused on better spam filtering methodologies or on understanding the botnets commonly used to send spam. In this paper, we aim to understand the origins of spam. We post dedicated email addresses to record how and where spammers go to obtain email addresses. We find that posting an email address on public Web pages yields immediate and high-volume spam. Surprisingly, even simple email obfuscation approaches are still sufficient today to prevent spammers from harvesting emails. We also find that attempts to find open relays continue to be popular among spammers. The insights we gain on the use of Web crawlers used to harvest email addresses and the commonalities of techniques used by spammers open the door for radically ...

2009-07-01

198

Solar system constraints on a Rindler-type extra-acceleration from modified gravity at large distances  

CERN Document Server

We analytically work out the orbital effects caused by a Rindlertype extra-acceleration ARin which naturally arises in some recent models of modified gravity at large distances. In particular, we focus on the perturbations induced by it on the two-body range {\\rho} and range-rate {\\rho}\\cdot which are commonly used in satellite and planetary investigations as primary observable quantities. The constraints obtained for ARin by comparing our calculations with the currently available range and range-rate residuals for some of the major bodies of the solar system, obtained without explicitly modeling ARin, are 1 - 2 \\times 10-13 m s-2 (Mercury and Venus), 1 \\times 10-14 m s-2 (Saturn), 1 \\times 10-15 m s-2 (Mars), while for a terrestrial Rindler acceleration we have 5 \\times 10-16 m s-2 (Moon). Another approach which could be followed consists of taking into account ARin in re-processing all the available data sets with accordingly modified dynamical models, and estimating a ...

2010-01-01

199

Serviceability of steam generators at NPPs with reactors of the WWER-440 and WWER-1000 types  

Energy Technology Data Exchange (ETDEWEB)

Steam generators (SG) are the weak link of nuclear power plants, their service life is shorter than the service life of other NPP components. This paper is dedicated to a statistical analysis of SG damages and failures. Heat exchanging tubes (HET) are the most damaged elements in SG, there are on average 286 plugged or repaired tubes in each operating SG. The usually mechanisms of tube failure are the following: denting, corrosion at tube outside, pitting, fretting, and circular crack propagation. Most of damages are located in the transition zone above a tube plate. This study shows that the factors that are involved in the SG HET fault probability are: - design features of SG and secondary equipment elements (high pressure feed heaters (HPFH), low pressure feed heater (LPFH)), - water chemistry at different points of condensate feed pipe, composition and density of deposits on HET surface, efficiency of mechanical and chemical washing, - the physical and chemical ...

2002-07-01

200

Report on the International Peer Review of RAINS-ASIA  

Energy Technology Data Exchange (ETDEWEB)

Many Asian countries have experienced rapid economic growth during recent years and this trend is expected to continue. The economic growth is accompanied by increasing energy demand, with coal as the dominant energy source. For the first time a model has been specifically developed and applied for integrated assessment of future SO{sub 2} emissions in Asia. The report deals with the RAINS-ASIA model developed in Norway offering an opportunity to assess sulphur deposition and ecosystem protection levels resulting from different energy pathways and different emission control strategies. The cost of various control strategies are also provided. During the project an impressive database has been collected for the region (23 countries, 94 subregions and 355 large point sources). This was made possible through dedicated work by the project team, in close collaboration with scientific and technical institutions in several Asian countries. A further development of the ...

1995-10-01

201

Real-time 3-D SAFT-UT system evaluation and validation  

International Nuclear Information System (INIS)

SAFT-UT technology is shown to provide significant enhancements to the inspection of materials used in US nuclear power plants. This report provides guidelines for the implementation of SAFT-UT technology and shows the results from its application. An overview of the development of SAFT-UT is provided so that the reader may become familiar with the technology. Then the basic fundamentals are presented with an extensive list of references. A comprehensive operating procedure, which is used in conjunction with the SAFT-UT field system developed by Pacific Northwest Laboratory (PNL), provides the recipe for both SAFT data acquisition and analysis. The specification for the hardware implementation is provided for the SAFT-UT system along with a description of the subsequent developments and improvements. One development of technical interest is the SAFT real time processor. Performance of the real-time processor is impressive and comparison is made of this dedicated ...

1993-05-17

202

Quasi-metrics, Similarities and Searches: aspects of geometry of protein datasets  

CERN Document Server

A quasi-metric is a distance function which satisfies the triangle inequality but is not symmetric: it can be thought of as an asymmetric metric. The central result of this thesis, developed in Chapter 3, is that a natural correspondence exists between similarity measures between biological (nucleotide or protein) sequences and quasi-metrics. Chapter 2 presents basic concepts of the theory of quasi-metric spaces and introduces a new examples of them: the universal countable rational quasi-metric space and its bicompletion, the universal bicomplete separable quasi-metric space. Chapter 4 is dedicated to development of a notion of the quasi-metric space with Borel probability measure, or pq-space. The main result of this chapter indicates that `a high dimensional quasi-metric space is close to being a metric space'. Chapter 5 investigates the geometric aspects of the theory of database similarity search in the context of quasi-metrics. The results about $pq$-spaces ...

2008-01-01

203

Polysilicon thin film transistors fabricated on low temperature plastic substrates  

Energy Technology Data Exchange (ETDEWEB)

We present device results from polysilicon thin film transistors (TFTs) fabricated at a maximum temperature of 100&hthinsp;{degree}C on polyester substrates. Critical to our success has been the development of a processing cluster tool containing chambers dedicated to laser crystallization, dopant deposition, and gate oxidation. Our TFT fabrication process integrates multiple steps in this tool, and uses the laser to crystallize deposited amorphous silicon as well as create heavily doped TFT source/drain regions. By combining laser crystallization and doping, a plasma enhanced chemical vapor deposition SiO{sub 2} layer for the gate dielectric, and postfabrication annealing at 150&hthinsp;{degree}C, we have succeeded in fabricating TFTs with I{sub ON}/I{sub OFF} ratios {gt}5{times}10{sup 5} and electron mobilities {gt}40 cm{sup 2}/V&hthinsp;s on polyester substrates. {copyright} {ital 1999 American Vacuum Society.}

1999-07-01

204

Performance of the upgraded LTP-II at the ALS Optical Metrology Laboratory  

Energy Technology Data Exchange (ETDEWEB)

The next generation of synchrotrons and free electron laser facilities requires x-ray optical systems with extremely high performance, generally of diffraction limited quality. Fabrication and use of such optics requires adequate, highly accurate metrology and dedicated instrumentation. Previously, we suggested ways to improve the performance of the Long Trace Profiler (LTP), a slope measuring instrument widely used to characterize x-ray optics at long spatial wavelengths. The main way is use of a CCD detector and corresponding technique for calibration of photo-response non-uniformity [J. L. Kirschman, et al., Proceedings of SPIE 6704, 67040J (2007)]. The present work focuses on the performance and characteristics of the upgraded LTP-II at the ALS Optical Metrology Laboratory. This includes a review of the overall aspects of the design, control system, the movement and measurement regimes for the stage, and analysis of the performance by a slope measurement of a ...

2008-07-14

205

Multiscale modeling of skeletal muscle properties and experimental validations in isometric conditions.  

Science.gov (United States)

In this article, we describe an approach to model the electromechanical behavior of the skeletal muscle based on the Huxley formulation. We propose a model that complies with a well established macroscopic behavior of striated muscles where force-length, force-velocity, and Mirsky-Parmley properties are taken into account. These properties are introduced at the microscopic scale and related to a tentative explanation of the phenomena. The method used integrates behavior ranging from the microscopic to the macroscopic scale, and allows the computation of the dynamics of the output force and stiffness controlled by EMG or stimulation parameters. The model can thus be used to simulate and carry out research to develop control strategies using electrical stimulation in the context of rehabilitation. Finally, through animal experiments, we estimated model parameters using a Sigma Point Kalman Filtering technique and dedicated experimental protocols in isometric ...

2011-07-15

206

Merging of airborne gravity and gravity derived from satellite altimetry: Test cases along the coast of greenland  

DEFF Research Database (Denmark)

The National Survey and Cadastre - Denmark (KMS) has for several years produced gravity anomaly maps over the oceans derived from satellite altimetry. During the last four years, KMS has also conducted airborne gravity surveys along the coast of Greenland dedicated to complement the existing onshore gravity coverage and fill in new data in the very-near coastal area, where altimetry data may contain gross errors. The airborne surveys extend from the coastline to approximately 100 km offshore, along 6000 km of coastline. An adequate merging of these different data sources is important for the use of gravity data especially, when computing geoid models in coastal regions. The presence of reliable marine gravity data for independent control offers an opportunity to study procedures for the merging of airborne and satellite data around Greenland. Two different merging techniques, both based on collocation, are investigated in this paper. Collocation offers a way of ...

2002-01-01

207

Meeting future exhaust emissions standards using natural gas as a vehicle fuel: Lessons learned from the natural gas vehicle challenge `92  

Energy Technology Data Exchange (ETDEWEB)

The Natural Gas Vehicle Challenge `92, organized by Argonne National Laboratory and sponsored by the US Department of Energy, the Energy, Mines, and Resources - Canada, the Society of Automotive Engineers, and many others, resulted in 20 varied approaches to the conversion of a gasoline-fueled, spark-ignited, internal combustion engine to dedicated natural gas use. Starting with a GMC Sierra 2500 pickup truck, donated by General Motors, teams of college and university student engineers strived to optimize Chevrolet V-8 engines operating on natural gas for improved emissions, fuel economy, performance, and advanced design features. This paper focuses on the results of the emission event, and compares engine mechanical configurations, engine management systems, catalyst configurations and locations, and approaches to fuel control and the relationship of these parameters to engine-out and tailpipe emissions of regulated exhaust constituents. Nine of the ...

1992-09-01

208

Measurement of "2"3"3U(n,f) cross-section at n_TOF facility. Statistical analysis  

International Nuclear Information System (INIS)

The "2"3"3U(n, f) cross-section has been measured at n_TOF in a wide energy range with a dedicated fission ionization chamber. We report here the results from 0.30 meV to 1 MeV neutron energy. The "2"3"3U(n, f) cross-section has been determined relative to a reference sample of "2"3"5U(n, f) measured simultaneously with the same detector. The very high instantaneous neutron flux and the intrinsically low background of the n TOF installation result in an accuracy around 3% in the whole energy range, while the energy resolution of the neutron beam allows for an accurate description of the fission cross-section by means of R-matrix analysis over a wide energy range. The present data provide the basis for a more precise evaluation of the "2"3"3U fission cross-section, and for improving the reliability of databases needed for the design of new energy systems based on the Th/U cycle. (Author)

2009-02-01

209

International symposium: concepts for the treatment of wastewater in the rural areas of Europe. Proceedings; Internationales Symposium: Konzepte zur Abwasserbehandlung im laendlichen Raum Europas. Tagungsband  

Energy Technology Data Exchange (ETDEWEB)

In the first part of the symposium, experts reviewed the state of the art of decentralized waste water treatment in Europe. In the second part, exemplary solutions in Poland and the Czech Republic were presented. The final part was dedicated to future concepts and strategies. [German] Im Herbst letzten Jahres hat die Kommunale Umwelt-AktioN U.A.N. in einer Abfolge von drei Abwasserfachsymposien Expertenrunden zum Austausch ueber den aktuellen Stand des Wissens zum Thema dezentrale Abwasserbehandlung veranstaltet. Mit dem Internationalen Symposium 'Konzepte zur Abwasserbehandlung im laendlichen Raum Europas' in Celle hat das Projekt der U.A.N. seinen Abschluss gefunden. Der Konzeption des Projektes entsprechend haben im 1. Teil des Symposiums Experten ueber den Stand der Entwicklung auf dem Sektor der dezentralen Abwasserbehandlung in Deutschland berichtet. Im 2. Teil unserer Fachtagung wurden europaeische Beispiele fuer dezentrale Loesungen aus ...

2000-07-01

210

International symposium on nuclear security. Book of extended synopses  

International Nuclear Information System (INIS)

The International Symposium on Nuclear Security took place within a context of international acknowledgement that the threat of nuclear terrorism required dedicated action by the international community, States, industry and others. The Symposium dealt with those issues involved in protecting nuclear and other radioactive material from criminals. It also took place against a backdrop of renewed interest in nuclear technology: increased use of nuclear power, and increased use of radioactive isotopes in medicine and in industry. These are welcome developments, since nuclear energy and technology can indeed contribute to the technological and economic welfare of many countries, without compromising public health or the environment. In this context, security measures should not impede State programmes for peaceful use of nuclear technology. The symposium dealt with (1) the threat of nuclear terrorism and of other nuclear-related criminal acts; (2) international ...

2003-11-05

211

IN VACUUM UNDULATOR TASK FORCE REPORT  

Energy Technology Data Exchange (ETDEWEB)

The Green-Chasman lattice, which is the basis for both NSLS storage rings, was conceived with insertion devices in mind. Long, field-free straight sections were provided in the design. The electron optics were chosen so that these sections had zero dispersion and the effects of new magnetic structures placed in these regions would have minimal effect on the emittance of the electron beam. This design concept has been followed by all high-brightness rings which were built subsequent to the NSLS. The X-Ray Ring straight sections also have a very small vertical {beta} function, in addition to the zero dispersion. This was done to optimize the brightness of wiggler sources. There is a further benefit however. The {beta} function determines the beam size and divergence at a particular point in the storage ring lattice. The size is proportional to {radical}{beta} and the divergence is proportional to 1/{radical}{beta}. Thus the electron beam is very small at the center of the X-Ray Ring ...

1998-06-01

212

HAMMER FY 1996 Multi-Year Program Plan: WBS {number_sign}8.2  

Energy Technology Data Exchange (ETDEWEB)

The Hazardous Material Management and Emergency Response Training and Education Center -- known simply as HAMMER -- is being developed to assist the US Department of Energy (DOE) and others dedicated to improving worker health, safety and productivity. HAMMER is a training and education program for hazardous material, waste management, and emergency response workers. HAMMER is managed by the DOE Richland Operations Office under Work Breakdown Structure (8.2). The 1996 Multi-Year Program Plan (MYPP) includes the Execution Year data and provides the information for Programmatic Fiscal Year Site Management System Execution Baseline, as well as the detailed work plan for performance evaluation of the authorized work. The MYPP incorporates various planning methodologies to define the program and provides essential program integration, and a fully developed technical, cost, and schedule baseline. The MYPP will be utilized by WHC Program and Department Managers as the ...

1995-09-01

213

Dry coke quenching study. Final report, September 1978  

Science.gov (United States)

The financial evaluation of capital and operating cost estimates for a dry coke quenching facility installation indicates a marginal return on investment if the evaluation is based exclusively on steam credits. However, the potential improvements in environmental emissions and reported, but unverified, blast furnace operations may justify the expenditure. The Russian and Japanese claim of 2 to 4% reduction in blast furnace coke usage with up to 4% increase in iron production has not been demonstrated in the domestic steel industry and, therefore, is not included in the financial analysis. A 2% coke reduction represents a savings of approximately $0.81 per ton of hot metal produced or an additional annual credit of $1,800,000 for dry coke quenching, exclusive of productivity gains. Additional credit of this magnitude would increase the estimated discounted cash flow return from 10% to approximately 16% for the estimated capital expenditure of $21,742,652. The projected world escalation ...

1978-09-01

214

Development of a Simple Scheme for Prediction of Flame Acceleration and DDT  

International Nuclear Information System (INIS)

Hydrogen combustion phenomenology during severe accidents in nuclear power plants has been a safety issue. Especially, flame acceleration (FA) and Deflagration-to-Detonation Transition (DDT) are important because of their possible destructive impact on the containment or plant systems in it. Accordingly, it is the design goal to avoid FA and DDT for the hydrogen mitigation system. As a result from extensive effort dedicated to resolve the hydrogen issue, compiled information on the FA and DDT has been provided by the NEA. The FA criterion was suggested in terms of the mixture expansion ratio ? , and the criterion for onset of DDT was based on the greatness of the geometrical size of the reactive system compared with the detonation cell width ? of the average mixture composition. The DDT onset criterion reflects the current state of knowledge based on the experimental database; however, the criterion is not sufficient but a necessary condition. Therefore, it should ...

2010-10-01

215

Design improvements and operational experience of programmable digital comparator system  

International Nuclear Information System (INIS)

Application of Programmable Digital Comparator System (PDCS) in NPP is to monitor large number of plant parameters and generate contact outputs for reactor trip, reactor setback, process interlocks etc. when parameters cross their operational bounds. Till NAPS these functions are achieved through individual Indicating Alarm Meters (IAM). PDCS used for the first time in KAPS replaces these IAMs. Since its inception, PDCS has undergone improvements in design, incorporates additional functionalities/enhanced features. Dedicated PDCS is provided in TAPP-3 and 4 for protection function. System re-configurability, on-line inter channel comparison of safety critical process parameters' values, Graphic User Interface etc. are other enhancements. From KAPS to TAPP-4 system has given many years of almost trouble-free operation. Commissioning of TAPP-3 system has been very smooth. Objective of the paper is to describe the advantage of the new system, its operating experience, ...

2006-11-13

216

Cybercars Past, Present and Future of the Technology  

CERN Document Server

Automobile has become the dominant transport mode in the world in the last century. In order to meet a continuously growing demand for transport, one solution is to change the control approach for vehicle to full driving automation, which removes the driver from the control loop to improve efficiency and reduce accidents. Recent work shows that there are several realistic paths towards this deployment : driving assistance on passenger cars, automated commercial vehicles on dedicated infrastructures, and new forms of urban transport (car-sharing and cybercars). Cybercars have already been put into operation in Europe, and it seems that this approach could lead the way towards full automation on most urban, and later interurban infrastructures. The European project CyberCars has brought many improvements in the technology needed to operate cybercars over the last three years. A new, larger European project is now being prepared to carry this work further in order to ...

2005-01-01

217

Computational AstroStatistics Fast and Efficient Tools for Analysing Huge Astronomical Data Sources  

CERN Document Server

I present here a review of past and present multi-disciplinary research of the Pittsburgh Computational AstroStatistics (PiCA) group. This group is dedicated to developing fast and efficient statistical algorithms for analysing huge astronomical data sources. I begin with a short review of multi-resolutional kd-trees which are the building blocks for many of our algorithms. For example, quick range queries and fast n-point correlation functions. I will present new results from the use of Mixture Models (Connolly et al. 2000) in density estimation of multi-color data from the Sloan Digital Sky Survey (SDSS). Specifically, the selection of quasars and the automated identification of X-ray sources. I will also present a brief overview of the False Discovery Rate (FDR) procedure (Miller et al. 2001a) and show how it has been used in the detection of ``Baryon Wiggles'' in the local galaxy power spectrum and source identification in radio data. Finally, I will look ...

2001-01-01

218

Compendium of federal and state radioactive materials transportation laws and regulations: Transportation Legislative Database (TLDB)  

International Nuclear Information System (INIS)

The Transportation Legislative Database (TLDB) is an on-line information service containing detailed information on legislation and regulations regarding the transportation of radioactive materials in the United States. The system is dedicated to serving the legislative and regulatory information needs of the US Department of Energy and other federal agencies; state, tribal, and local governments; the hazardous materials transportation industry; and interested members of the general public. In addition to the on-line information service, quarterly and annual Legal Developments Reports are produced using information from the TLDB. These reports summarize important changes in federal and state legislation, regulations, administrative agency rulings, and judicial decisions over the reporting period. Information on significant legal developments at the tribal and local levels is also included on an as-available basis. Battelle's Office of Transportation Systems and ...

1989-01-01

219

Coded Single-Tone Signaling for Resource Coordination and Interference Management in Femtocell Networks  

CERN Document Server

Resource coordination and interference management is the key to achieving the benefits of femtocell networks. Over-the-air signaling is one of the most effective means for distributed dynamic resource coordination and interference management. However, the design of this type of signal is challenging. In this letter, we address the challenges and propose an effective solution, referred to as coded single-tone signaling (STS). The proposed coded STS scheme possesses certain highly desirable properties, such as no dedicated resource requirement (no overhead), no near-and-far effect, no inter-signal interference (no multi-user interference), low peak-to-average power ratio (deep coverage). In addition, the proposed coded STS can fully exploit frequency diversity and provides a means for high quality wideband channel estimation. The coded STS design is demonstrated through a concrete numerical example. Performance of the proposed coded STS is evaluated through ...

2011-01-01

220

Cluster Analysis of Gene Expression Data  

CERN Document Server

The expression levels of many thousands of genes can be measured simultaneously by DNA microarrays (chips). This novel experimental tool has revolutionized research in molecular biology and generated considerable excitement. A typical experiment uses a few tens of such chips, each dedicated to a single sample - such as tissue extracted from a particular tumor. The results of such an experiment contain several hundred thousand numbers, that come in the form of a table, of several thousand rows (one for each gene) and 50 - 100 columns (one for each sample). We developed a clustering methodology to mine such data. In this review I provide a very basic introduction to the subject, aimed at a physics audience with no prior knowledge of either gene expression or clustering methods. I explain what genes are, what is gene expression and how it is measured by DNA chips. Next I explain what is meant by "clustering" and how we analyze the massive amounts of data from such ...

2002-01-01

221

Characterization system for Germanium detectors dedicated to gamma spectroscopy applied to nuclear waste  

International Nuclear Information System (INIS)

CEA-Valduc produces some radioactive waste (mainly alpha emitters). Legislation requires producers to sort their waste by activity and type of isotopes, and to package them in order to forward them to the appropriate reprocessing or storage facility. Our lab LMDE (laboratory for measurements on nuclear wastes and valuation) is in charge of the characterization of the majority of waste produced by CEA-Valduc. Among non-destructive methods to characterize a radioactive object, gamma-spectroscopy is one of the most efficient. We present to this conference the method we use to characterize nuclear waste and the system we developed to characterize our germanium detectors. The goal of this system is to obtain reliable numerical models of our detectors and calculate their efficiency curves. Measurements are necessary to checks models and improve them. These measurements are made on a bench using pinpoint sources ("1"3"3Ba, "1"5"2Eu) from 60 keV to 1500 keV, with distances from 'on contact' to ...

2009-06-07

222

BINERY PSEUDO-RANDOM GRATING AS A STANDARD TEST SURFACE FOR MEASUREMENT OF MODULATION TRANSFER FUNCTION OF INTERFEROMETRIC MICROSCOPES.  

Energy Technology Data Exchange (ETDEWEB)

The task of designing high performance X-ray optical systems requires the development of sophisticated X-ray scattering calculations based on rigorous information about the optics. One of the most insightful approaches to these calculations is based on the power spectral density (PSD) distribution of the surface height. The major problem of measurement of a PSD distribution with an interferometric and/or atomic force microscope arises due to the unknown Modulation Transfer Function (MTF) of the instruments. The MTF characterizes the perturbation of the PSD distribution at higher spatial frequencies. Here, we describe a new method and dedicated test surfaces for calibration of the MTF of a microscope. The method is based on use of a specially designed Binary Pseudo-random (BPR) grating. Comparison of a theoretically calculated PSD spectrum of a BPR grating with a spectrum measured with the grating provides the desired calibration of the instrumental MTF. The ...

2007-08-01

223

Automatic Gamma-Scanning System for Measurement of Residual Heat in Spent Nuclear Fuel  

International Nuclear Information System (INIS)

In Sweden, spent nuclear fuel will be encapsulated and placed in a deep geological repository. In this procedure, reliable and accurate spent fuel data such as discharge burnup, cooling time and residual heat must be available. The gamma scanning method was proposed in earlier work as a fast and reliable method for the experimental determination of such spent fuel data. This thesis is focused on the recent achievements in the development of a pilot gamma scanning system and its application in measuring spent fuel residual heat. The achievements include the development of dedicated spectroscopic data-acquisition and analysis software and the use of a specially designed calorimeter for calibrating the gamma scanning system. The pilot system is described, including an evaluation of the performance of the spectrum analysis software. Also described are the gamma-scanning measurements on 31 spent PWR fuel assemblies performed using the pilot system. The results obtained ...

224

Automatic Gamma-Scanning System for Measurement of Residual Heat in Spent Nuclear Fuel  

Energy Technology Data Exchange (ETDEWEB)

In Sweden, spent nuclear fuel will be encapsulated and placed in a deep geological repository. In this procedure, reliable and accurate spent fuel data such as discharge burnup, cooling time and residual heat must be available. The gamma scanning method was proposed in earlier work as a fast and reliable method for the experimental determination of such spent fuel data. This thesis is focused on the recent achievements in the development of a pilot gamma scanning system and its application in measuring spent fuel residual heat. The achievements include the development of dedicated spectroscopic data-acquisition and analysis software and the use of a specially designed calorimeter for calibrating the gamma scanning system. The pilot system is described, including an evaluation of the performance of the spectrum analysis software. Also described are the gamma-scanning measurements on 31 spent PWR fuel assemblies performed using the pilot system. The results obtained ...

2007-03-15

225

Applications with a new low-temperature UHV STM at 5 K  

International Nuclear Information System (INIS)

A new dedicated UHV STM for investigations at T#<=#5 K is presented. To achieve such low temperatures and to ensure a high thermal stability, the low-temperature (LT) STM described here has a concentric system of bath cryostats. There are openings for tip and sample exchange at low T, and windows with an infrared radiation shield for optical access, which can both be closed by a door mechanism for LT-STM measurements. Efficient vibration isolation is realized by using spring suspension with eddy current damping. With the 3-d coarse positioning unit any region of interest within 5 mm by 5 mm on the sample is accessible even at 5 K. For short turn-around cycles the sample and tip can both be exchanged at low temperatures. Atomically resolved images of Au(111) at 5 K in UHV demonstrate the excellent performance of this LT STM. As a typical application example the appearance of a charge-density wave on NbSe_2, which occurs below a transition temperature of 33.5 K, ...

1998-03-01

226

Application of quality improvement techniques to meet coke battery environmental regulations  

Science.gov (United States)

Citizens Gas and Coke Utility operates three coke oven batteries, producing both foundry coke and blast furnace coke, under the trade name Indianapolis Coke. Active participation in the regulation negotiation process by the Vice President of Indianapolis Coke allowed the company to accurately anticipate the environmental regulations, long before they were set in law. Several improvements were put into motion that helps them meet the new environmental regulations. Better trained operators with new job positions dedicated solely to environmental compliance, an extensive environmental training program, and two innovations, a portable oven door milling and cleaning machine and three new computer applications are the result of team efforts. The focus of this paper is development of the computer applications designed to enhance three areas of environmental compliance. The three areas addressed by the applications are documentation and information deployment, problem ...

1993-01-01

227

An overview on the study of quark gluon plasma with Alice dimuon spectrometer; Apercu sur l'etude du plasma de Quarks et de gluons a l'aide du spectrometre dimuons d'Alice  

Energy Technology Data Exchange (ETDEWEB)

The Alice experiment is one of the four main LHC (Large Hadron Collider) experiments. It is dedicated to the study of a new state of matter: the quark gluon plasma, where quarks and gluons are no longer confined within hadrons. In this document, the physics issues that led to the construction of Alice dimuon spectrometer, are described. Then, the research and development on the dimuon spectrometer is presented. The different absorbers are described and experimental tests used to determine their dimensions are presented. The dimuon trigger built using the RPC (Resistive Plate Chamber) streamer mode is then described along with the associated beam and cosmic tests and results. Finally, the tracking system is described in detail and more particularly all its electronics and the first station. The physics constraints on the expected performances of all these systems are clearly defined. (author)

2007-10-15

228

A New Green Power Inverter for Fuel Cells  

DEFF Research Database (Denmark)

This paper presents a new grid connected inverter for fuel cells. It consists of a two stage power conversion topology. Since the fuel cell operates with a low voltage in a wide voltage range (25 V-45 V) this volt- age must be transformed to around 350-400 V in order to invert this dc power into ac power to the grid. The proposed converter consists of an isolated dc-dc converter cascaded with a single phase H-bridge inverter. The dc-dc converter is a current-fed push-pull converter. A new dedicated voltage mode startup procedure has been developed in order to limit the inrush current during startup. The inverter is controlled as a power factor controller with resistor emulation.Experimental results of converter efficiency, grid performance and fuel cell response are shown for a 1 kW prototype. The proposed converter exhibits a high efficiency in a wide power range (higher than 92%) and the inverter operates with a near unity power factor and a low current THD.

2002-01-01

229

X-ray phase imaging using a X-ray tube with a small focal spot. Improvement of image quality in mammography  

International Nuclear Information System (INIS)

Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and the screen-film system was determined for phase imaging of mammography. In order to investigate a potential for medical application of this method, we conducted evaluation of the images of the American Collage of Radiology (ACR) ...

2002-03-01

230

Use of Teflon-embedded calcium sulphate: dysprosium thermoluminescent dosimeters for chest radiography  

Energy Technology Data Exchange (ETDEWEB)

As part of a U.S. multi-regional pilot study conducted by the six Centers for Radiological Physics, 12-mm-diameter by 0.4-mm-thick CaSO/sub 4/:Dy Teflon-embedded discs were evaluated and used to measure patient entrance exposure on 60 average patients at 12 clinical centers. The discs were found to have adequate sensitivity, reproducibility and linearity up to 69.7 microC kg-1 (270 mR). The minimum measurable exposure was estimated as 0.4 microC kg-1 (1.5 mR). All responses were corrected for energy dependence, which varied +/- 20% from 1.7 to 6.5 mm Al half-value layer. Patient entrance exposure values ranged from 1.3 to 28 microC kg-1 (5 to 110 mR), with a median value of 5.2 microC kg-1 (20 mR). This value agreed with exposure measurements made on the chest radiography equipment using an ionization chamber and a phantom which simulated an average patient, and with published Nationwide Evaluation of X-Ray Trends (NEXT) data for the same period.

1987-12-01

231

The validity of the density scaling method in primary electron transport for photon and electron beams  

International Nuclear Information System (INIS)

In the convolution/superposition method of photon beam dose calculations, inhomogeneities are usually handled by using some form of scaling involving the relative electron densities of the inhomogeneities. In this paper the accuracy of density scaling as applied to primary electrons generated in photon interactions is examined. Monte Carlo calculations are compared with density scaling calculations for air and cork slab inhomogeneities. For individual primary photon kernels as well as for photon interactions restricted to a thin layer, the results can differ significantly, by up to 50%, between the two calculations. However, for realistic photon beams where interactions occur throughout the whole irradiated volume, the discrepancies are much less severe. The discrepancies for the kernel calculation are attributed to the scattering characteristics of the electrons and the consequent oversimplified modeling used in the density scaling method. A technique called the kernel integration ...

232

The treatment of chronic pain by epidural spinal cord stimulation--a 15 year follow up; present status.  

Science.gov (United States)

Pain is necessary for survival but chronic pain is disabling and causes significant health and economic problems. This study provides an understanding of the future for spinal cord stimulation. Stimulation by means of chronically implanted electrodes, was carried out in 200 patients with pain of varied benign organic etiology. In 177 of them, pain was confined to the failed back syndrome. Most patients were referred by a Pain Management Service. 226 epidural implants were used: 80 unipolar, 59 Resume, 12 bipolar, and 75 quadripolar. Patients were followed for periods of 6 months to 12 years, with a mean follow-up of 44 months. 84 patients (42%) were able to control their pain by stimulation alone, 22 patients (11%) needed occasional analgesic supplements along with their stimulation program. Pain secondary to failed back syndrome, multiple sclerosis, peripheral vascular disease, sympathetic dystrophy and diabetic neuropathy responded favorably. Pain due to cauda equina injury, ...

1997-06-01

233

Simultaneous assessment of left ventricular function from gated myocardial perfusion SPECT. Utility of QGS (Quantitative Gated SPECT) program  

International Nuclear Information System (INIS)

Quantitative gated SPECT (QGS) was evaluated in 7 normal volunteers and 31 patients with cardiac diseases. Adequate cut off value of a prefilter was 0.45. In phantom, the left ventricular volume value was 93.9% of determined value by 180-degree projection in L type and 98.8% by 360-degree projection in opposed type. In normal volunteers, LVEF measured by QGS program related to value by first pass method. As for functional map, regional EF and wall motion decreased at the septum side, and wall thickening at base side of heart. Good correlation was recognized (p<0.0001) between blood flow image and functional map (regional EF and wall thickening). In 20 cases of acute myocardial infarction, lesion was detected conspicuously in regional EF and wall motion. The accuracy of coronary arterial stenosis improved in functional map (regional EF 92%, wall motion 92% and wall thickening 88%). In particular, the accuracy of 3 rami lesion was 100% in functional map and higher ...

1998-08-01

234

Scatter measurements for optical cone-beam computed tomography  

Energy Technology Data Exchange (ETDEWEB)

Both x-ray and optical cone-beam CT (CBCT) scanners are limited by scattered photons that contaminate the primary images. Transparent radiochromic gels and plastics are anticipated to produce less scattering than polymerization gels and hence result in reconstructed dose distributions with greater contrast and dynamic range. Four methods of scatter measurement were investigated to quantify scatter fractions using an in-house optical CBCT scanner. The methods consisted of generating either 'coin' shadows or primary beamlets in transmission images. The four methods generated similar results of 10% scatter fractions in gel transmission images for this particular scanner configuration with both leuco crystal violet and carbon black micelle gels. The scatter contributions were distributed as 5% from micelle gel, 2% from Teflon wall, 2% from refractive index matching liquid and 1% other sources. Applying a uniform background subtraction of 2% of open field intensity ...

2009-05-01

235

Pharmacokinetic and dosimetric characteristics of some thallium isotopes  

International Nuclear Information System (INIS)

Pharmacokinetics is studied, radiation doses to patients when using domestic thallium-201 chloride in diagnosis of the heart ischemic disease is estimated; contribution into the total dose of thallium-201 (1.5 %), thallium-201 (0.2 %) and lead-201 + lead-203 (0.05 %) radionuclide impurities is also determined. Internal doses were estimated for a heterogeneous phantom of a standard man; the calculations were carried out using a computer. Scanning of patients which were treated with radiopharmaceuticals to be diagnosed was carried out using a whole body counter and gamma-chamber. Large intestine, kidneys and thyroid are the critical organs when using thallium-201 chloride. The highest contribution into the dose to organs and the whole body from thallium-200 and thallium-202 impurities being contained in thallium-201, doesn't exceed 8.6 %. The contribution into the dose from lead-201 and lead-203 may be ignored. Doses from thallium-199 preparation per activity unit ...

236

Performance testing of selected types of electronic personal dosimeters used in Sudan  

International Nuclear Information System (INIS)

Measurements were carried out for calibration and performance testing of a set of 10 electronic personal dosimeters (EPDs) at the Secondary Standard Dosimetry Laboratory of Sudan. Calibrations were carried out at three X-ray beam qualities described in ISO standard 4037 in addition to 137Cs and 60Co gamma ray beams. The experimental was performed with EPDs mounted on ICRU Slab phantom. X-ray and ?-ray beams were characterized in terms of air kerma free-in-air which were converted to the known delivered personal dose equivalent, Hp(10) using appropriate the air kerma to personal dose equivalent conversion coefficients. Dosimeters tested showed excellent energy and angular response and relative error of indication within the recommended limit for photon energies from 65 keV to 1.25 MeV. The study showed encouraging results for using electronic dosimeters in personal dosimetry.

2010-12-01

237

On the accuracy and effectiveness of dose reconstruction for tomotherapy  

International Nuclear Information System (INIS)

Dose reconstruction is a process that re-creates the treatment-time dose deposited in a patient provided there is knowledge of the delivered energy fluence and the patient's anatomy at the time of treatment. A method for reconstructing dose is presented. The process starts with delivery verification, in which the incident energy fluence from a treatment is computed using the exit detector signal and a transfer matrix to convert the detector signal to energy fluence. With the verified energy fluence and a CT image of the patient in the treatment position, the treatment-time dose distribution is computed using any model-based algorithm such as convolution/superposition or Monte Carlo. The accuracy of dose reconstruction and the ability of the process to reveal delivery errors are presented. Regarding accuracy, a reconstructed dose distribution was compared with a measured film distribution for a simulated breast treatment carried out on a thorax phantom. It was found ...

2001-04-01

238

Measurement of spatial dose distribution with thermoluminescence sheet around high dose-rate intracavitary sup 60 Co sources  

Energy Technology Data Exchange (ETDEWEB)

A thermoluminescence (TL) sheet and its spatial readout system for in vivo measurement of spatial dose distribution around sources has been newly developed for intracavitary high dose-rate radiation therapy. The TL sheet (40 cm x 50 cm x 200 {mu}m), which is composed of teflon mixed with BaSO{sub 4} (Eu doped) powder, has a linear response with a very wide dynamic range from at least 0.002 cGy to 5000 cGy for {sup 60}Co sources. Phantom test of the TL sheet readout system demonstrated that absorbed dose with TL sheet and that with ionization chamber as standard dosimeter agreed well. For clinical application, TL sheet was attached on an applicator of intracavitary radiation therapy for rectal cancer. After irradiation with high dose-rate {sup 60}Co sources, the in vivo dose distribution on the surface of the rectum was determined. The TL sheet was suggested to provide a convenient means of measuring the dose distribution around {sup 60}Co sources in intracavitary ...

1991-06-01

239

Is energy imparted a good measure of the radiation risk associated with CT examinations  

International Nuclear Information System (INIS)

The dose distribution in a Rando phantom has been measured for typical EMI 5005 CT scans of the head, chest, abdomen and pelvis. These dose distributions have been used to generate quantitative estimates of the somatic and genetic radiation risks associated with these CT examinations and also to measure the total energy imparted during each scan. A comparison has been made between the radiation risk estimates and the energy imparted measurements. The energy imparted measurements are not a good indicator of the somatic and/or genetic risks when one type of CT scan is compared with another. However, for a given type of scan, the energy imparted may be a reasonable indicator of the relative somatic risks associated with different CT examinations. Considerable care should be taken when interpreting and using any measured value of energy imparted in a radiological examination since published values of the risk per unit energy imparted can significantly underestimate the ...

240

Improvement of spatial resolution in the longitudinal direction for isotropic imaging in helical CT  

Energy Technology Data Exchange (ETDEWEB)

Experiments were conducted to confirm the isotropic spatial resolution of multislice CT with a 0.5 mm slice thickness. Isotropic spatial resolution means that the spatial resolution in the transaxial plane (X-Y plane) and that in the longitudinal direction (Z direction) are equivalent. To obtain point spread function (PSF) values in the X-Y-Z directions, three-dimensional voxel data were obtained by helical scanning of a bead phantom. The modulation transfer function (MTF) values were then obtained by three-dimensional Fourier transform of the PSF. Evaluation of the spatial resolution in the X-Y-Z directions by the MTF values showed that the spatial resolution in the Z direction does not depend on the reconstruction kernel used. It was also found that the spatial resolution in the Z direction, as compared with that in the X-Y plane, is superior with the standard kernel for the abdomen and is inferior with the high-definition kernel for the ears/bones. By performing ...

2007-02-07

241

Fluorescence based molecular in vivo imaging; Fluoreszenzgestuetzte molekulare Bildgebung in vivo  

Energy Technology Data Exchange (ETDEWEB)

Molecular imaging represents a modern research area that allows the in vivo study of molecular biological process kinetics using appropriate probes and visualization methods. This methodology may be defined- apart from the contrast media injection - as non-abrasive. In order to reach an in vivo molecular process imaging as accurate as possible the effects of the used probes on the biological should not be too large. The contrast media as important part of the molecular imaging can significantly contribute to the understanding of molecular processes and to the development of tailored diagnostics and therapy. Since more than 15 years PTB is developing optic imaging systems that may be used for fluorescence based visualization of tissue phantoms, small animal models and the localization of tumors and their predecessors, and for the early recognition of inflammatory processes in clinical trials. Cellular changes occur during many diseases, thus the molecular imaging ...

2008-12-15

242

Fluence-convolution broad-beam (FCBB) dose calculation  

International Nuclear Information System (INIS)

IMRT optimization requires a fast yet relatively accurate algorithm to calculate the iteration dose with small memory demand. In this paper, we present a dose calculation algorithm that approaches these goals. By decomposing the infinitesimal pencil beam (IPB) kernel into the central axis (CAX) component and lateral spread function (LSF) and taking the beam's eye view (BEV), we established a non-voxel and non-beamlet-based dose calculation formula. Both LSF and CAX are determined by a commissioning procedure using the collapsed-cone convolution/superposition (CCCS) method as the standard dose engine. The proposed dose calculation involves a 2D convolution of a fluence map with LSF followed by ray tracing based on the CAX lookup table with radiological distance and divergence correction, resulting in complexity of O(N"3) both spatially and temporally. This simple algorithm is orders of magnitude faster than the CCCS method. Without pre-calculation of beamlets, its implementation is also ...

2010-12-07

243

Experimental determination of the dosimetric characteristics for the I-Plant"T"M model 3600 "1"2"5I brachytherapy source  

International Nuclear Information System (INIS)

The dosimetric characteristics for a new brachytherapy seed source (I-Plant"T"M model 3600) were measured using LiF thermoluminescent dosimeters and appropriate phantom materials in conformance with the methodology and guidance provided by the AAPM Task Group 43. The I-Plant"T"M model 3600 is the successor to the I-Plant"T"M model 3500. The major difference between these sources is that the model 3600 contains a leaded-glass core to provide radio-opacity (while the model 3500 contains a silver core), which does not produce spectral contamination upon neutron activation. The dose rate constant #LAMBDA# for the model 3600 was determined to be 1.00 Gy h"-"1 U"-"1 (with a 6% overall relative standard deviation), compared to 1.01 cGy h"-"1 U"-"1 reported for the model 3500 in previous studies. The remaining dosimetric characteristics also are similar for both sources.

2005-06-01

244

Evaluation of the increase of superficial dose due to thermoplastic immobilizing in radiotherapy; Avaliacao dos efeitos de superficializacao de dose por imobilizadores termoplasticos em radioterapia  

Energy Technology Data Exchange (ETDEWEB)

Perforated thermoplastic masks are used to provide patients immobilization. This procedure inserts a material in the path of the radiation beam, that attenuates and modifies the beam fluence and flatness. The present study evaluates the increase in skin dose as a result of using thermoplastic masks. Relative doses were measured on the surface of a solid water phantom, in the presence and absence of masks. These masks were stretched according to deformation patterns observed in clinical routine. The measurements were obtained with a plane-parallel chamber (Markus type 23343) and radiochromic film (EBT Gafchromic) for 6MV X-rays from a linear accelerator, and for a radiation beam from a cobalt therapy unit. The results showed that thermoplastic masks, whose thickness varied between 2 and 3 mm, increased the dose on the surface by a factor of 3. Due to the variations in the skin dose distribution, clinical procedures were suggested to minimize radiobiological damages ...

2010-07-01

245

Evaluation of the increase of superficial dose due to thermoplastic immobilizing in radiotherapy  

International Nuclear Information System (INIS)

Perforated thermoplastic masks are used to provide patients immobilization. This procedure inserts a material in the path of the radiation beam, that attenuates and modifies the beam fluence and flatness. The present study evaluates the increase in skin dose as a result of using thermoplastic masks. Relative doses were measured on the surface of a solid water phantom, in the presence and absence of masks. These masks were stretched according to deformation patterns observed in clinical routine. The measurements were obtained with a plane-parallel chamber (Markus type 23343) and radiochromic film (EBT Gafchromic) for 6MV X-rays from a linear accelerator, and for a radiation beam from a cobalt therapy unit. The results showed that thermoplastic masks, whose thickness varied between 2 and 3 mm, increased the dose on the surface by a factor of 3. Due to the variations in the skin dose distribution, clinical procedures were suggested to minimize radiobiological damages ...

2010-08-18

246

Dosimetric characteristics of backscattered electrons in lead  

Energy Technology Data Exchange (ETDEWEB)

In electron beam therapy, tissue overdose due to electrons backscattered from lead has been profusely studied. To quantify this dose enhancement effect, an electron backscatter factor (EBF) wasdefined as the ratio of dose at the tissue-inhomogeneity interface with and without the scatterer present. The dependence of the EBF on energy at the scatterer surface is not well known for energies lower than 3 MeV which is the most frequent clinical situation. In this work, we have done Monte Carlo calculations with the GEANT code to study EBF in lead at this energy range. The applicability of this code and the developed procedure for dose estimation has been experimentally verified. The dependence of the EBF on the beam energy incident on the scatterer has been studied for different nominal beam energies incident at the phantom's surface. The results show a trend of increase of EBF with the beam energy incident on the scatterer between 0.5 and 1.5 MeV, keeping ...

2000-07-01

247

Diagnostic capability of digital radiography of the chest using scanning laser stimulated luminescence  

Energy Technology Data Exchange (ETDEWEB)

Diagnostic capability of Fuji Computed Radiography (FCR) of the chest was compared to the conventional radiography (CoR) using regular film-screen system. FCR utilizers imaging plates of scanning laser stimulated luminescence. Visibility of 14 structures of the chest radiography was evaluated by 3 radiologists in 100 pairs of FCR and CoR which were taken at the same time with the same exposure factors. FCR was superior to CoR especially in observation of the mediastinum and areas behind the heart and diaphragm. The minor fissure was better seen on CoR. Superiority of FCR to CoR was thought to be mainly due to the processed image of FCR, and the so-called normal image of FCR had little diagnostic advantage. Simulated abnormal densities: nodular, alveolar, and interstitial densities with a chest phantom, were made, and detectability of alteration of these densities on FCR and CoR was evaluated by 19 radiologists, using ROC curve analysis. FCR and CoR revealed the ...

1989-02-01

248

Diagnostic capability of digital radiography of the chest using scanning laser stimulated luminescence  

International Nuclear Information System (INIS)

Diagnostic capability of Fuji Computed Radiography (FCR) of the chest was compared to the conventional radiography (CoR) using regular film-screen system. FCR utilizers imaging plates of scanning laser stimulated luminescence. Visibility of 14 structures of the chest radiography was evaluated by 3 radiologists in 100 pairs of FCR and CoR which were taken at the same time with the same exposure factors. FCR was superior to CoR especially in observation of the mediastinum and areas behind the heart and diaphragm. The minor fissure was better seen on CoR. Superiority of FCR to CoR was thought to be mainly due to the processed image of FCR, and the so-called normal image of FCR had little diagnostic advantage. Simulated abnormal densities: nodular, alveolar, and interstitial densities with a chest phantom, were made, and detectability of alteration of these densities on FCR and CoR was evaluated by 19 radiologists, using ROC curve analysis. FCR and CoR revealed the ...

1989-01-01

249

Development of a dual-detector X-ray imaging system for phase retrieval study  

International Nuclear Information System (INIS)

Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons detected by the two detectors, respectively and the imaging quality of phantoms. Preliminary results showed that the system is ...

2007-01-01

250

Determinations of organ or tissue doses to survivors in Hiroshima and Nagasaki  

International Nuclear Information System (INIS)

For the purpose of risk estimates from radiation carcinogenesis including leukemogenesis and radiation genetic effects, the biological significant dose is not the tissue kerma in air but the absorbed dose in organ or tissue with respect to carcinogenic and leukemogenic effects or genetic effects. In order to estimate organ or tissue dose from the tissue kerma in air, a ratio of the organ or tissue dose to the tissue kerma in air for survivors in Hiroshima and Nagasaki was calculated with the aid of the Snyder's mathematical phantoms constructed so as to simulate the body shape of survivors aged 5, 10 years old and adult at the time of atomic bomb detonations. The ratios were corrected for the angular distribution of atomic bomb radiations, assuming an anisotropic angular distribution for the survivors exposed to the atomic bombs in open air and the isotropic distribution for the survivors incide a Japanese house or other structures. The resultant ratios are ...

1980-01-01

251

Computed radiography  

International Nuclear Information System (INIS)

In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in the lung field and in the retrocardiac and subdiaphragmatic regions, respectively. This may have implications for the value of ...

1987-01-01

252

Chromosome aberrations in human lymphocytes from the plateau region of the Bragg curve for a carbon-ion beam  

Energy Technology Data Exchange (ETDEWEB)

Radiotherapy with high-energy carbon ion beams can be more advantageous compared to photons because of better physical dose distribution and higher biological efficiency in tumour cell sterilization. Despite enhanced normal tissue sparing, damage incurred by normal cells at the beam entrance is unavoidable and may affect the progeny of surviving cells in the form of inheritable cytogenetic alterations. Furthermore, the quality of the beam along the Bragg curve is modified by nuclear fragmentation of projectile and target nuclei in the body. We present an experimental approach based on the use of a polymethylmethacrylate (PMMA) phantom that allows the simultaneous exposure to a particle beam of several biological samples positioned at various depths along the beam path. The device was used to measure the biological effectiveness of a 60 MeV/amu carbon-ion beam at inducing chromosomal aberrations in G{sub 0}-human peripheral blood lymphocytes. Chromosome spreads were ...

2007-06-15

253

BDTPS The BNCT Treatment Planning System jointly developed at DIMNP and JRC/IE  

CERN Document Server

The idea to couple the Treatment Planning System (TPS) to the information on the real boron distribution in the patient is the main added value of the new methodology set-up at DIMNP of University of Pisa, in collaboration with the JRC of Petten (NL). The methodology has been implemented in the new TPS, called BDTPS (Boron Distribution Treatment Planning System), which takes into account the actual boron distribution in the patient brain, while the standard TPS assumes a uniform boron distribution, absolutely far from the reality. Nowadays, Positron Emission Tomography (PET) is able to provide this in vivo information. The new TPS, based on the Monte Carlo technique, has been validated comparing the main BNCT parameters (thermal flux, boron dose, etc.) as measured during the irradiation of a special heterogeneous boron phantom (HEBOM), ad hoc designed, as calculated by the BDTPS and by the standard TPS SERA. An evident SERA overestimation of the thermal neutron ...

2003-01-01

254

Assessment of the effects of pixel loss on image quality in direct digital radiography  

Energy Technology Data Exchange (ETDEWEB)

Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitative image quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line pairs phantom were found to be more sensitive to pixel loss. Measurement of the MTF, NPS and DQE can ...

2004-03-21

255

Assessment of the effects of pixel loss on image quality in direct digital radiography  

International Nuclear Information System (INIS)

Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitative image quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line pairs phantom were found to be more sensitive to pixel loss. Measurement of the MTF, NPS and DQE can reveal small changes in image quality ...

2004-03-21

256

A comparison study for dose calculation in radiation therapy: pencil beam Kernel based vs. Monte Carlo simulation vs. measurements  

International Nuclear Information System (INIS)

Accurate dose calculation in radiation treatment planning is most important for successful treatment. Since human body is composed of various materials and not an ideal shape, it is not easy to calculate the accurate effective dose in the patients. Many methods have been proposed to solve inhomogeneity and surface contour problems. Monte Carlo simulations are regarded as the most accurate method, but it is not appropriate for routine planning because it takes so much time. Pencil beam kernel based convolution/superposition methods were also proposed to correct those effects. Nowadays, many commercial treatment planning systems have adopted this algorithm as a dose calculation engine. The purpose of this study is to verify the accuracy of the dose calculated from pencil beam kernel based treatment planning system comparing to Monte Carlo simulations and measurements especially in inhomogeneous region. Home-made inhomogeneous phantom, Helax-TMS ver. 6.0 and Monte ...

2002-10-20

257

Study on dose distribution of therapeutic proton beams with prompt gamma measurement  

Energy Technology Data Exchange (ETDEWEB)

The proton beam has an advantage of the sharp dose falloff in dose distribution called Bragg peak while conventional radiation therapy modalities such as photons exhibit considerable amount of exit dose. To take advantage of this property it is important to know the exact location of the distal dose falloff. An error can cause overdose to the normal tissue or underdose to the tumor volume. The only way of finding out the dose distribution in-situ in particle therapy is to measure the gammas produced by nuclear reactions with tissue materials. Two kinds of gammas can be used: one is prompt gamma and the other is coincident gamma from the positron-emission isotopes. We chose to detect prompt gammas, and developed a prompt gamma scanning system (PGS). The proton beams of the proton therapy facility at National Cancer Center were used. The gamma distribution was compared to the dose distribution measured by an ionization chamber at three different energies of 100, 150, 200 MeV's. ...

2007-03-15

258

Accurate convolution/superposition for multi-resolution dose calculation using cumulative tabulated kernels  

International Nuclear Information System (INIS)

Convolution/superposition (C/S) is regarded as the standard dose calculation method in most modern radiotherapy treatment planning systems. Different implementations of C/S could result in significantly different dose distributions. This paper addresses two major implementation issues associated with collapsed cone C/S: one is how to utilize the tabulated kernels instead of analytical parametrizations and the other is how to deal with voxel size effects. Three methods that utilize the tabulated kernels are presented in this paper. These methods differ in the effective kernels used: the differential kernel (DK), the cumulative kernel (CK) or the cumulative-cumulative kernel (CCK). They result in slightly different computation times but significantly different voxel size effects. Both simulated and real multi-resolution dose calculations are presented. For simulation tests, we use arbitrary kernels and various voxel sizes with a homogeneous phantom, and assume ...

2005-02-21

259

A stochastic convolution/superposition method with isocenter sampling to evaluate intrafraction motion effects in IMRT  

International Nuclear Information System (INIS)

Current methods to calculate dose distributions with organ motion can be broadly classified as 'dose convolution' and 'fluence convolution' methods. In the former, a static dose distribution is convolved with the probability distribution function (PDF) that characterizes the motion. However, artifacts are produced near the surface and around inhomogeneities because the method assumes shift invariance. Fluence convolution avoids these artifacts by convolving the PDF with the incident fluence instead of the patient dose. In this paper we present an alternative method that improves the accuracy, generality as well as the speed of dose calculation with organ motion. The algorithm starts by sampling an isocenter point from a parametrically defined space curve corresponding to the patient-specific motion trajectory. Then a photon is sampled in the linac head and propagated through the three-dimensional (3-D) collimator structure corresponding to a particular MLC segment chosen randomly from ...

2005-04-01

260

MRI evaluation and image processing in gel dosimetry. A study of selected MRI properties and image processing in 3D gel dosimetry  

Energy Technology Data Exchange (ETDEWEB)

Gel dosimetry is a new dosimetry method applied in radiation therapy. Gel dosimeters consist of a radiation sensitive gel, which can integrate absorbed doses from several radiation sources or beams. The dose to the gel can be evaluated by magnetic resonance imaging (MRI), a procedure that is the focus of the present thesis. A robust tool for the evaluation of the nonuniformity in MRI has been developed, the Deviation Image method. Unlike previously presented methods, the Deviation Image method includes all nonuniformity variations across a phantom surface and is insensitive to stochastic noise. Methods for the estimation of stochastic noise were analyzed in terms of sensitivity to nonuniformities. A method that averages the stochastic noise level over five regions over the phantom surface, and a method that assesses the stochastic noise level from the background, were found to be the methods of choice. Pronounced MR image nonuniformity ...

2001-03-01

261

Implementation of an algorithm for absorbed dose calculation in high energy photon beams at off axis points  

International Nuclear Information System (INIS)

Full text: A semiempirical algorithm for absorbed dose calculation at off-axis points in irregular beams was implemented. It is well known that semiempirical methods are very useful because of their easy implementation and its helpfulness in dose calculation in the clinic. These methods can be used as independent tools for dosimetric calculation in many applications of quality assurance. However, the applicability of such methods has some limitations, even in homogeneous media, specially at off axis points, near beam fringes or outside the beam. Only methods derived from tissue-air-ratio (TAR) or scatter-maximum-ratio (SMR) have been devised for those situations, many years ago. Despite there have been improvements for these manual methods, like the Sc-Sp ones, no attempt has been made to extend their usage at off axis points. In this work, a semiempirical formalism was introduced, based on the works of Venselaar et al. (1999) and Sanz et al. (2004), aimed to the Sc-Sp separation. This ...

2008-10-19

262

Verification of the CFD code FLUENT by post test calculation of the ROCOM experiment T665521; Validierung des CFD codes FLUENT anhand der Nachrechnung des ROCOM Experimentes T665521  

Energy Technology Data Exchange (ETDEWEB)

During the last years one focus of German PWR safety analysis was boron dilution events with the potential of reactivity transients. Coolant with a low boron concentration could be collected in localized areas of the reactor coolant system e.g. by separation of borated reactor coolant into highly concentrated and diluted fractions (inherent dilution) which can occur during reflux- condenser heat transfer after a small break loss of coolant accident with a limited availability of the emergency core cooling systems. The TUeV NORD SysTec was charged by German supervisory authorities with the assessment of the safety analyses of boron dilution events presented by the utilities. These analyses are based on the simulation of boron dilution and transport processes in conjunction with a number of dedicated experiments. The analyses shall demonstrate that boron dilution events cannot lead to recriticality of the core. Hence the boron concentration at the core inlet has to ...

2005-05-01

263

Verification of the CFD code FLUENT by post test calculation of the ROCOM experiment T665521  

International Nuclear Information System (INIS)

During the last years one focus of German PWR safety analysis was boron dilution events with the potential of reactivity transients. Coolant with a low boron concentration could be collected in localized areas of the reactor coolant system e.g. by separation of borated reactor coolant into highly concentrated and diluted fractions (inherent dilution) which can occur during reflux- condenser heat transfer after a small break loss of coolant accident with a limited availability of the emergency core cooling systems. The TUeV NORD SysTec was charged by German supervisory authorities with the assessment of the safety analyses of boron dilution events presented by the utilities. These analyses are based on the simulation of boron dilution and transport processes in conjunction with a number of dedicated experiments. The analyses shall demonstrate that boron dilution events cannot lead to recriticality of the core. Hence the boron concentration at the core inlet has to ...

2005-05-01

264

Validation of the CFD code fluent by post-test calculation of a density-driven ROCOM experiment  

Energy Technology Data Exchange (ETDEWEB)

During the last years, boron dilution events with the potential of reactivity transients were an important issue of German PWR safety analyses. A coolant with a low-boron concentration could be collected in localized areas of the reactor coolant system, e.g., by separation of a borated reactor coolant into highly concentrated and diluted fractions (inherent dilution) which can occur during reflux-condenser heat transfer after a small break loss of coolant accident with a limited availability of the emergency core cooling systems. During the course of follower core assessments, TUV NORD SysTec appraises safety analyses of boron dilution events presented by the utilities. These analyses are based on the simulation of boron dilution and transport processes in conjunction with a number of dedicated experiments. The analyses demonstrate that boron dilution events cannot lead to recriticality of the core. Hence, the boron concentration at the core inlet has to be ...

2007-09-15

265

Using modified foragers to harvest short-rotation poplar plantations  

Energy Technology Data Exchange (ETDEWEB)

In Italy, short rotation coppice (SRC) has become very popular in recent years, with over 4000 ha already planted - almost exclusively with clonal poplar. Commercial harvesting operations are dominated by modified foragers, equipped with dedicated SRC headers. At present, contractors use two main header types: German Claas HS-2 and Italian GBE. The former fits smaller foragers with a power below 300 kW, the latter is used on larger harvest units. This study models the performance of modified foragers on a range of short-rotation poplar plantations. Data were collected from 45 operations, covering a total of 118 ha and producing over 4400 green tonnes of wood chips. The average yield of the fields harvested during the trials was about 23 gt ha{sup -1} year{sup -1} (at a moisture content of 59%), and machine productivity ranged from 9 to 70 green tonnes per scheduled machine hour (gt SMH{sup -1}), with an average value of 35 gt SMH{sup -1}. A model was developed to ...

2009-05-15

266

Turning wood residues into wood revenues  

Energy Technology Data Exchange (ETDEWEB)

Ensyn is a profitable commercial company which derives its revenues from the conversion of wood residues into liquid biofuel and chemicals. The technology, Rapid Thermal Processing (RTP{sup (TM)})is based on extremely fast ``cracking`` of biomass which results in light liquid yields exceeding 70% by weight, from wood. Whether producing chemicals or liquid biofuel, the RTP plant is configured identically and operated essentially in the same mode. Chemicals production simply allows economical production to occur at a lower plant capacity, as low as 2 tonnes/day, than is feasible for a dedicated fuel plant (typically greater than 100 tonnes/day). Ensyn has developed the commercialisation of RTP{sup TM} from bench to industrial scale in 10 years. A variety of crative funding initiatives in the early years allowed for capital to be raised for R and D without the loss of intellectual property (IP). The transition years of technology demonstration, prior to full ...

1996-06-01

267

The composition-explicit distillation curve technique: Relating chemical analysis and physical properties of complex fluids.  

Science.gov (United States)

The analysis of complex fluids such as crude oils, fuels, vegetable oils and mixed waste streams poses significant challenges arising primarily from the multiplicity of components, the different properties of the components (polarity, polarizability, etc.) and matrix properties. We have recently introduced an analytical strategy that simplifies many of these analyses, and provides the added potential of linking compositional information with physical property information. This aspect can be used to facilitate equation of state development for the complex fluids. In addition to chemical characterization, the approach provides the ability to calculate thermodynamic properties for such complex heterogeneous streams. The technique is based on the advanced distillation curve (ADC) metrology, which separates a complex fluid by distillation into fractions that are sampled, and for which thermodynamically consistent temperatures are measured at atmospheric pressure. The collected sample ...

2009-11-17

268

Surface-water-resources information for the Ho-Chunk Nation lands and vicinity, Wisconsin  

Science.gov (United States)

The Ho-Chunk Nation is interested in documenting water-quality conditions in streams adjacent to their Reservation lands in Wisconsin and developing management plans to protect these water resources. The Nation uses these waterways for recreation and as a source for food, and therefore, is dedicated to maintaining and restoring their quality. Ho-Chunk lands encompass more than 10,000 acres ranging primarily over 17 counties in Wisconsin. The study areas for this report include streams adjacent to Ho-Chunk Nation residential lands: Potch-Hah-Chee, Sandpillow, Mission, Bluewing, Chakh Hah Chee, Winnebago Heights, Indian Heights, and Ho-Chunk Village. These residential areas, or housing sites, are located along or near the Middle Branch Embarrass, Black, Lemonweir, and Wisconsin Rivers or their tributaries. Water-quality data were compiled and summarized, and basin maps showing land cover and previous sampling sites are presented. Qualitative assessments of factors ...

2003-01-01

269

Simulation of embedded systems for energy consumption estimation  

Energy Technology Data Exchange (ETDEWEB)

Technology developments in semiconductor fabrication along with a rapid expansion of the market for portable devices, such as PDAs and mobile phones, make the energy consumption of embedded systems a major problem. Indeed the need to provide an increasing number of computational intensive applications and at the same time to maximize the battery life of portable devices can be seen as incompatible trends. System simulation is a flexible and convenient method for analyzinging and exploring the performance of a system or sub-system. At the same time, the increasing use of computational intensive applications strengthens the need to maximize the battery life of portable devices. As a consequence, the simulation of embedded systems for energy consumption estimation is becoming essential in order to study and explore the influence of system design choices on the system energy consumption. The original publications presented in the second part of this thesis propose several frameworks for ...

2009-07-01

270

Silicon purification melting for photovoltaic applications  

Energy Technology Data Exchange (ETDEWEB)

The availability of polysilicon feedstock has become a major issue for the photovoltaic (PV) industry in recent years. Most of the current polysilicon feedstock is derived from rejected material from the semiconductor industry. However, the reject material can become scarce and more expensive during periods of expansion in the integrated-circuit industry. Continued rapid expansion of the PV crystalline-silicon industry will eventually require a dedicated supply of polysilicon feedstock to produce solar cells at lower costs. The photovoltaic industry can accept a lower purity polysilicon feedstock (solar-grade) compared to the semiconductor industry. The purity requirements and potential production techniques for solar-grade polysilicon have been reviewed. One interesting process from previous research involves reactive gas blowing of the molten silicon charge. As an example, Dosaj et all reported a reduction of metal and boron impurities from silicon melts using ...

2000-04-01

271

Session 1: Geothermal Pumping Systems and Two-Phase Flow Studies  

Energy Technology Data Exchange (ETDEWEB)

Improvements in electric submersible pumping systems have resulted in a demonstrated downhole running life of one year for low horsepower units operating in 180 C brine. The implementation of a prototype pressurized lubrication system to prevent brine intrusion and loss of lubricating oil from the motor and protector sections has been successfully tested. Second generation pressurized lubrication systems have been designed and fabricated and will be utilized in downhole production pumping tests during FY84. Pumping system lifetime is currently limited by available power cable designs that are degraded by high-temperature brine. A prototype metal-sheathed power cable has been designed and fabricated and is currently undergoing destructive and nondestructive laboratory testing. This cable design has the potential for eliminating brine intrusion into the power delivery system through the use of a hermatically sealed cable from the surface to the downhole motor. The two-phase flow program ...

1983-12-01

272

Sequential chemical treatment of radium species in TENORM waste sludge produced from oil and natural gas production.  

Science.gov (United States)

This paper is dedicated to the treatment of sludge occurring in frame of the Egyptian produced from oil and gas production. The activity levels of three radium isotopes: Ra-226 (of U-series), Ra-228 and Ra-224 (of Th-series) in the solid TENORM waste (sludge) were first evaluated and followed by a sequential treatment for all radium species (fractions) presented in TENORM. The sequential treatment was carried out based on two approaches 'A' and 'B' using different chemical solutions. The results obtained indicate that the activity levels of all radium isotopes (Ra-226, Ra-228 and Ra-224) of the environmental interest in the TENORM waste sludge were elevated with regard to exemption levels established by IAEA [International Atomic Energy Agency (IAEA), International basic safety standards for the protection against ionizing radiation and for the safety of radiation sources. GOV/2715/Vienna, 1994]. Each approach of the sequential treatment was performed through four ...

2008-04-18

273

Sequential chemical treatment of radium species in TENORM waste sludge produced from oil and natural gas production  

Energy Technology Data Exchange (ETDEWEB)

This paper is dedicated to the treatment of sludge occurring in frame of the Egyptian produced from oil and gas production. The activity levels of three radium isotopes: Ra-226 (of U-series), Ra-228 and Ra-224 (of Th-series) in the solid TENORM waste (sludge) were first evaluated and followed by a sequential treatment for all radium species (fractions) presented in TENORM. The sequential treatment was carried out based on two approaches 'A' and 'B' using different chemical solutions. The results obtained indicate that the activity levels of all radium isotopes (Ra-226, Ra-228 and Ra-224) of the environmental interest in the TENORM waste sludge were elevated with regard to exemption levels established by IAEA [International Atomic Energy Agency (IAEA), International basic safety standards for the protection against ionizing radiation and for the safety of radiation sources. GOV/2715/Vienna, 1994]. Each approach of the sequential ...

2009-01-30

274

Scroll compressor for heat pumps in old and new residential buildings; Scroll-Verdichter fuer Waermepumpen zur Wohnraumheizung in Alt- und Neubauten  

Energy Technology Data Exchange (ETDEWEB)

Heat pumps for residential space heating become an increasingly important alternative to the conventional heating system like gas or oil burner. They offer the opportunity to reduce CO{sub 2} emission associated with heating residential homes in Germany. High compressors efficiency and a wide operating map are required so that an economically viable heat pumps is achieved which meets the operational conditions for present and future heating systems. The design parameter of existing heating systems require relatively high condensing temperatures which can be achieved with dedicated compressor designs. The design of Scroll compressors specially adapted to these heat pumps is shown and their operation is explained. (orig.) [German] Waermepumpen fuer die Wohnraumheizung gewinnen an Bedeutung als Alternative zur konventionellen Gas- oder Oelheizung. Sie bieten die Moeglichkeit, die mit der Gebaeudeheizung verbundene Emission von Kohlendioxid in Deutschland zu ...

2003-07-01

275

Report on the achievements in research and development of a coal liquefaction technology in the Sunshine Project in fiscal 1981. Development of a solvent extraction and liquefaction plant (research and development of secondary hydrogenation); 1981 nendo sekitan ekika gijutsu no kenkyu kaihatsu, yozai chushutsu ekika plant no kaihatsu seika hokokusho. Niji suiten no kenkyu kaihatsu  

Energy Technology Data Exchange (ETDEWEB)

Among the items of the Sunshine Project in fiscal 1981 for development of a solvent extraction and liquefaction plant, this paper describes the achievements in developing secondary hydrogenation. A small continuous hydrogenation device equipped with three reaction columns that can be filled with catalyst of 50 cc, and a dedicated testing room were designed, and orders were placed with manufacturers. The fabrication, assembly, delivery, installation, piping and wiring were all completed. The device passed a completion inspection based on the high-pressure gas safety assurance law in December 1981. After leakage due to gas and material oil was checked, a trial operation was performed, and verified of normal operation. A screening test was carried out on three kinds of commercially available and prototype catalysts before testing the SRC containing material for studying the secondary hydrogenation. The circulating solvent having a boiling point from 180 to 430 degree ...

1982-03-01

276

Radon in soil gas survey in Curitiba (Brazil)  

International Nuclear Information System (INIS)

This work describes the radon in soil gas measurements performed during the last two years in cooperation between the Laboratory of Applied Nuclear Physics of the Federal University of Technology (UTFPR), the Nuclear Technology Development Center (CDTN) and the Institute of Radiation Protection and Dosimetry (IRD) from the Brazilian Nuclear Energy Commission (CNEN). Following previously concluded measurements of radon concentration in dwellings and the measurements of 222Rn activity in drinking water collected at artesian bores of Curitiba urban area, present step of activities has been dedicated to measurements of radon concentration in soil gas. Experimental setup was based on the Professional Radon Monitor (ALPHA GUARD) connected to specially developed for such measurements Soil Gas Probe through the air pump and filter system. After the Probe was inserted, the ground has been tamped down around the probe, to prevent air from moving vertically along the outside ...

2002-10-08

277

Phase Formation and Transformations in Transmutation Fuel Materials for the LIFE Engine Part I - Path Forward  

Energy Technology Data Exchange (ETDEWEB)

The current specifications of the LLNL fusion-fission hybrid proposal, namely LIFE, impose severe constraints on materials, and in particular on the nuclear fissile or fertile nuclear fuel and its immediate environment. This constitutes the focus of the present report with special emphasis on phase formation and phase transformations of the transmutation fuel and their consequences on particle and pebble thermal, chemical and mechanical integrities. We first review the work that has been done in recent years to improve materials properties under the Gen-IV project, and with in particular applications to HTGR and MSR, and also under GNEP and AFCI in the USA. Our goal is to assess the nuclear fuel options that currently exist together with their issues. Among the options, it is worth mentioning TRISO, IMF, and molten salts. The later option will not be discussed in details since an entire report is dedicated to it. Then, in a second part, with the specific LIFE ...

2008-11-10

278

One-photon two-electron processes in helium close to the double ionization threshold; Diexcitation electronique de l'helium par un photon au voisinage du seuil de double ionisation  

Energy Technology Data Exchange (ETDEWEB)

This work presents a study of the {sup 1}P{sup 0} excited states of He that can be reached by absorption of a single photon carrying an energy close to the double ionization threshold (DIT) (79 eV). Above the DIT, these states are the double continuum states; below, they are the double excited states. These two types of states are tightly coupled to the single continuum states with or without excitation of the residual ion He{sup +}, owing to their degeneracy in energy. In a one-photon process, these states can only be formed owing to the electronic correlations in the system which must be well described to obtain quantitative good results. Our study is a part of the work which aims at a united description of all these doubly excited, ionized-excited, and double continuum states. We use the Hyperspherical R-Matrix with Semiclassical Outgoing Waves (HRM-SOW) method, initially dedicated to double photoionization studies. We extend it to extract information on the ...

2007-04-15

279

Natural ventilation of a room through a large external opening: calculation using a CFD code; Ventilation naturelle d`un local par une grande ouverture exterieure: calcul a l`aide d`un code de champ  

Energy Technology Data Exchange (ETDEWEB)

This paper is dedicated to the numerical study of natural ventilation in a room through a large external opening using the CFD code Fluent. Bidimensional numerical simulations are performed for wind speeds up to 5.55 m-s{sup -1} (20 km-h{sup -1}). We propose a two-step solution procedure with grid refinement. When combined with appropriate thermal boundary conditions, this technique appears very efficient at limiting local convergence problems. Through an analysis of the flow pattern in the cavity, we qualitatively explain those results and define a critical Archimedes number. Calculated air change rates are compared to values deduced from empirical correlations of the literature. Agreement is in general poor, which can be explained by the differences between the conditions of our simulations and those of the experiments that lead to those correlations. However, from our simulations, we derived very clear correlations between the air change coefficient and the ...

1998-02-01

280

Municipal solid waste management in Africa: Strategies and livelihoods in Yaounde, Cameroon  

International Nuclear Information System (INIS)

This paper provides an overview of the state of municipal solid waste (MSW) management in the capital of Cameroon, Yaounde, and suggests some possible solutions for its improvement. The institutional, financial, and physical aspects of MSW management, as well as the livelihoods of the population, were analyzed. Our study revealed that distances and lack of infrastructure have a major impact on waste collection. Garbage bins are systematically mentioned as the primary infrastructure needed by the population in all quarters, whether it be a high or low standard community. The construction of transfer stations and the installation of garbage bins are suggested as a solution to reduce distances between households and garbage bins, thus improving waste collection vehicle accessibility. Transfer stations and garbage bins would enable the official waste collection company to expand its range of services and significantly improve waste collection rates. Several transfer stations have already ...

2009-02-01

281

Multislice spiral CT (MSCT) in pediatric radiology: dose reduction for chest and abdomen examinations  

International Nuclear Information System (INIS)

The advent of multislice spiral CT (MSCT) technique has led to new aspects of dose reduction, especially for the dedicated use of MSCT in children. Optimizing pediatric MSCT protocols according to the clinical problem allows reduction of radiation exposure to a minimum without loss of diagnostic quality. The different parameters that influence the degree of dose reduction, like tube current-time product (mAs), tube voltage (kV), collimation and pitch, are discussed in context with previously published data and our own experience in nearly 200 pediatric CT examinations. In our department, the effective mAs is calculated for a pediatric chest MSCT by multiplication of the body weight in kilogram with a factor of 1 to 1.5 and for a pediatric abdominal MSCT by multiplication with a factor of 2 to 2.5. To calculate the equivalent effective dose for a contrast media-enhanced 80 kV protocol, the effective mAs of the 120 kV protocol can be multiplied by 2.7. A factor less ...

2004-07-01

282

Methodology for the development and the UML (unified modified language) simulation of data acquisition and data processing systems dedicated to high energy physics experiments; Methodologie de developpement et de modelisation UML des systemes d'acquisition et de traitement en temps reel pour les experiences de physique des hautes energies  

Energy Technology Data Exchange (ETDEWEB)

The increasing complexity of the real-time data acquisition and processing systems (TDAQ: the so called Trigger and Data AcQuisition systems) in high energy physics calls for an appropriate evolution of development tools. This work is about the interplay between in principle specifications of TDAQ systems and their actual design and realization on a concrete hardware and software platform. The basis of our work is to define a methodology for the development of TDAQ systems that meets the specific demands for the development of such systems. The result is the detailed specification of a 'methodological framework' based on the Unified Modeling Language (UML) and designed to manage a development process. The use of this UML-based methodological framework progressively leads to the setting up of a 'home-made' framework, i.e. a development tool that comprises reusable components and generic architectural elements adapted to TDAQ systems. The main parts of ...

2002-09-01

283

Measurement of the {beta}-{nu} angular correlation parameter in the decay of {sup 6}He using a Paul trap; Mesure du coefficient de correlation angulaire {beta}-{nu} dans la decroissance de {sup 6}He a l'aide d'un piege de Paul  

Energy Technology Data Exchange (ETDEWEB)

The central topic of this work is the study of the properties and the implementation of a Paul trap used for the measurement of the beta-neutrino angular correlation parameter in the decay of {sup 6}He. This coefficient provides a signature of the nature of the interactions involved in the weak interaction. The value of this coefficient can be deduced from the kinematical distribution of the decay events. An electromagnetic trap is used for the trapping of {sup 6}He{sup +} ions in a small volume. This trap has an open geometry that enables the detection in coincidence of the electron and the recoil ion emitted in the beta decay. A dedicated detection set up is used for the measurement of the electron energy, the ion time of flight and the position of the two particles for each event. A general description of the LPCTrap facility and of its performances is presented and shows that this set up is able to fulfill the proposed measurement. Especially, a comparison is ...

2007-07-15

284

LIFE Materials: Phase Formation and Transformations in Transmutation Fuel Materials for the LIFE Engine Part I - Path Forward Volume 3  

Energy Technology Data Exchange (ETDEWEB)

The current specifications of the LLNL fusion-fission hybrid proposal, namely LIFE, impose severe constraints on materials, and in particular on the nuclear fissile or fertile nuclear fuel and its immediate environment. This constitutes the focus of the present report with special emphasis on phase formation and phase transformations of the transmutation fuel and their consequences on particle and pebble thermal, chemical, and mechanical integrities. We first review the work that has been done in recent years to improve materials properties under the Gen-IV project, and with in particular applications to HTGR and MSR, and also under GNEP and AFCI in the USA. Our goal is to assess the nuclear fuel options that currently exist together with their issues. Among the options, it is worth mentioning TRISO, IMF, and molten salts. The later option will not be discussed in details since an entire report (Volume 8 - Molten-salt Fuels) is dedicated to it. Then, in a second ...

2008-12-19

285

High-accuracy "2"3"3U(n,f) cross-section measurement at the white-neutron source n_TOF from near-thermal to 1 MeV neutron energy  

International Nuclear Information System (INIS)

The "2"3"3U(n,f) cross section has been measured at the white neutron source n_TOF in a wide energy range with a dedicated fission ionization chamber. We report here the results from #approx#30 meV to 1 MeV neutron energy. The "2"3"3U(n,f) cross section has been determined relative to a reference sample of "2"3"5U(n,f) measured simultaneously with the same detector. The very high instantaneous neutron flux and the intrinsically low background of the n_TOF installation result in an accuracy around 3% in the whole energy range, while the energy resolution of the neutron beam allows for an accurate description of the fission cross section by means of R-matrix analysis over a wide energy range. The results are, in general, in good agreement with the most recent high-accuracy measurement of this fission cross section, over the more limited range of the previous measurements, and indicated that even the latest evaluations underestimate the cross section in the epithermal ...

2009-10-01

286

HVDC submarine power cables systems state of the art and future developments  

Energy Technology Data Exchange (ETDEWEB)

The paper begins with an introduction on the reasons that lead to the use of HVDC submarine cable links. The main aspects for the choice of direct current are presented as well as the advantages deriving from the utilization of submarine cables. The second part is dedicated to a discussion on the various type of insulation that could be used in power cables and their possible application to HVDC submarine cables. In the following there is a description of the main characteristics and technical details of some particular project that at present time (1995) are in progress. Two projects are briefly presented: Spain-Morocco, a 26 km long interconnection for the transmission, in a first phase, of 700 MW from Spain to Morocco at 400 kV a.c. by means of three cables, plus one spare, of the fluid filled type. The cables are designed for a future change to d.c. 450 kV, allowing a transmission of 500 MW each (i.e., 2 GW total). One of the peculiarities of the link is the ...

1995-12-31

287

HALO - the helium and lead observatory for supernova neutrinos  

Energy Technology Data Exchange (ETDEWEB)

The Helium and Lead Observatory (HALO) is a supernova neutrino detector under development for construction at SNOLAB. It is intended to fulfill a niche as a long term, low cost, high livetime, and low maintenance, dedicated supernova detector. It will be constructed from 80 tonnes of lead, from the decommissioning of the Deep River Cosmic Ray Station, and instrumented with approximately 384 meters of {sup 3}He neutron detectors from the final phase of the SNO experiment. Charged- and Neutral-Current neutrino interactions in lead expel neutrons from the lead nuclei making a burst of detected neutrons the signature for the detection of a supernova. Existing neutrino detectors are mostly of the water Cerenkov and liquid scintillator types, which are primarily sensitive to electron anti-neutrinos via charged-current interactions on the hydrogen nuclei in these materials. By contrast, the large neutron excess of a heavy nucleus like Pb acts to Pauli-block p)n ...

2008-11-01

288

Failure analysis and defect review using extended accuracy of the CrossBeam {sup registered} Technology  

Energy Technology Data Exchange (ETDEWEB)

The use of the focused ion beam (FIB) systems has increased to a high level in recent years. The imaging, milling, and deposition capabilities of the FIB make it the ideal instrument for e.g., site-specific failure analysis, specimen preparation and nano-machining. Ion channelling contrast allows for selective imaging of polycrystalline and polyphase microstructures. In addition, the FIB and CrossBeam registered instruments are unique stand-alone analytical tools. Their vast capabilities have enabled numerous applications into the semiconductor and materials sciences applications. These integrated CrossBeam registered Tools enable the observation and direct control of the FIB operation in real time. In addition to the improved accuracy and resolution the electron beam adds analytical capabilities as STEM, EDS and EBSP to the instruments. To ensure a safe and reliable operation of the instrument, a dedicated vacuum system is needed. This type of instrument combines ...

2005-07-01

289

Emission control cost-effectiveness of alternative-fuel vehicles  

Energy Technology Data Exchange (ETDEWEB)

Although various legislation and regulations have been adopted to promote the use of alternative-fuel vehicles for curbing urban air pollution problems, there is a lack of systematic comparisons of emission control cost-effectiveness among various alternative-fuel vehicle types. In this paper, life-cycle emission reductions and life-cycle costs were estimated for passenger cars fueled with methanol, ethanol, liquefied petroleum gas, compressed natural gas, and electricity. Vehicle emission estimates included both exhaust and evaporative emissions for air pollutants of hydrocarbon, carbon monoxide, nitrogen oxides, and air-toxic pollutants of benzene, formaldehyde, 1,3-butadiene, and acetaldehyde. Vehicle life-cycle cost estimates accounted for vehicle purchase prices, vehicle life, fuel costs, and vehicle maintenance costs. Emission control cost-effectiveness presented in dollars per ton of emission reduction was calculated for each alternative-fuel vehicle types from the estimated ...

1993-06-14

290

Dual energy virtual CT colonoscopy with dual source computed tomography. Initial experience  

International Nuclear Information System (INIS)

Purpose: To describe the technique of DE MDCT colonoscopy and to assess its feasibility. Materials and Methods: 8 patients were scanned with DSCT with a DE scan protocol and dose modulation software. Analysis was performed using dedicated DE software. Prone non-contrast images and DE supine images after contrast injection were obtained. Results: DE colonoscopic images were successfully obtained in 7 patients, but the FOV did not cover all colonic segments in 1 patient, thus resulting in a technical success rate was 87.5%. Streak artifacts were present in the pelvic region in 2 patients. Virtual unenhanced images and iodine map images were obtained for all patients. In 1 patient a polypoid non-enhancing structure was noted on the iodine map, and conventional colonoscopy revealed impacted stool. Enhancing rectal cancer in 1 patient was correctly shown on the iodine map. Iodine maps helped to differentiate stool fragments/retained fluid by the absence of enhancement ...

2009-09-01

291

Dosimetric evaluation and therapeutic response to iodine-131 labelled lipiodol in treatment of hepatocellular carcinomas; Evaluation dosimetrique et reponse therapeutique de la curietherapie metabolique des hepatocarcinomes par le lipiodol marque par l'iode 131  

Energy Technology Data Exchange (ETDEWEB)

Faced with increasing indications for the use of iodine-131 labelled lipiodol in the treatment of hepatocellular carcinoma (HCC), it appears essential to develop an individualized dosimetrY so we can predict the potential effectiveness of this treatment and adjust the activity to be injected. We developed a dosimetric protocol based on imagery and dedicated to calculation of the tumoral dose during the treatment of hepatocellular carcinoma by iodine-131 labelled lipiodol. This concept was developed on a SPECT- CT gantry, and integrates corrections for the phenomena of attenuation, diffusion and dead time. The dose is calculated according to the formalism proposed by the Medical Internal Radiation Dose Committee (MIRD). This protocol was applied to a series of 41 patients in the framework of a retrospective study. The results obtained in terms of biodistribution are compatible with previously published data. The total biological response rate is 42% (n= 41) for the ...

2006-12-15

292

Development of vehicle exhaust gas emissions. A balance of the effects of regulations ratified by the European Communities and of tax credits for low emission automobiles. A study on behalf of the Northrhine-Westphalian Ministry for Town Planning, Housing and Transportation. Die Entwicklungen der Schadstoffemissionen aus dem Kfz-Verkehr. Eine Bilanz der Auswirkungen der EG-Beschluesse und der steuerlichen Anreize zum schadstoffarmen Pkw. Studie im Auftrag des Ministers fuer Stadtentwicklung, Wohnen und Verkehr des Landes Nordrhein-Westfalen  

Energy Technology Data Exchange (ETDEWEB)

Due to the 'novel forest diseases' the political parties of the Federal Republic of Germany unanimously attend to the reduction of emissions. The transportation sector is considered to be a major emission source. A study discussed in the publication abstracted did therefore aim at giving a detailed account and description of the recently ratified technical requirements and tax credits expected to reduce vehicle exhaust gas air pollution. Moreover, the study researches into the regulations' importance as to the low emission properties of individual automobiles. Based on the results obtained the study arrives at assumptions as to emissions to be expected from the transportation sector. It tries to assess the financial import with respect to the individual citizen, overall internal revenues and federal motor vehicle taxes. The introductory chapter is followed by a review of emissions caused by vehicle exhaust gases along with a description of their historical ...

1985-01-01

293

Development of a dedicated ethanol ultra-low emission vehicle (ULEV) system design  

Energy Technology Data Exchange (ETDEWEB)

The objective of this 3.5 year project is to develop a commercially competitive vehicle powered by ethanol (or ethanol blend) that can meet California`s ultra-low emission vehicle (ULEV) standards and equivalent corporate average fuel economy (CAFE) energy efficiency for a light-duty passenger car application. The definition of commercially competitive is independent of fuel cost, but does include technical requirements for competitive power, performance, refueling times, vehicle range, driveability, fuel handling safety, and overall emissions performance. This report summarizes a system design study completed after six months of effort on this project. The design study resulted in recommendations for ethanol-fuel blends that shall be tested for engine low-temperature cold-start performance and other criteria. The study also describes three changes to the engine, and two other changes to the vehicle to improve low-temperature starting, efficiency, and emissions. The three engine ...

1995-02-01

294

Dentascan CT of mandibular incisive canal. Radiological anatomy and therapeutic implications; Tomografia computerizzata con Dentascan del canale incisivo mandibolare. Anatomia radiologica e implicazioni terapeutiche  

Energy Technology Data Exchange (ETDEWEB)

The main purpose of this paper is to stress the importance of CT depiction of the mandibular incisive canal. This anatomical structure contains a major neurovascular bundle and is thus very important in the planning of mandibular implants in the canine-incisive area. The importance of careful assessment of the mandibular canal course before implantology is now widely recognized. The same holds true for the canine-incisive region in the jaw, to detect the incisive canal if present and prevent any complications from its accidental damage. CT with a dedicated software showed the incisive canal in a large number of patients, which calls for precise reporting of its presence, course, and relationships with teeth. [Italian] Scopo di questo lavoro e' sottolineare l'importanza di rilevare e segnalare la visibilita' con Tomografia Computerizzata del canale incisivo mandibolare, struttura anatomica al cui interno decorre un fascio vasculo nervoso e ...

1999-11-01

295

Data Center Energy Benchmarking: Part 4 - Case Study on aComputer-testing Center (No. 21)  

Energy Technology Data Exchange (ETDEWEB)

The data center in this study had a total floor area of 8,580 square feet (ft{sup 2}) with one-foot raised-floors. It was a rack lab with 440 racks, and was located in a 208,240 ft{sup 2} multi-story office building in San Jose, California. Since the data center was used only for testing equipment, it was not configured as a critical facility in terms of electrical and cooling supply. It did not have a dedicated chiller system but served by the main building chiller plant and make-up air system. Additionally, it was served by a single electrical supply with no provision for backup power. The data center operated on a 24 hour per day, year-round cycle, and users had all hour full access to the data center facility. The study found that data center computer load accounted for 23% of the overall building electrical load, while the total power consumption attributable to the data center including allocated cooling load and lighting was 30% of the total facility load. ...

2007-08-01

296

Current status of siting a new near surface repository in Romania  

International Nuclear Information System (INIS)

Full text: The site selection process for a near surface repository dedicated for the radioactive waste resulted from the Cernavoda NPP operation and decommissioning started early in 90's. Each site selection stage included the collection of data from specific field and laboratory works as well as the appropriate safety performance evaluation. In order to assess/confirm the performance of the natural barrier of the Saligny site, the radionuclide concentration in the disposal system compartments has been evaluated, as complementary safety indicator of repository. The siting process was made in accordance with national and international regulations and standards and using a conceptual design similar to those used at L'Aube (France), ElCabril (Spain) or Mohovce (Slovak Republic). ANDRAD, the Romanian waste management organization that has continued the siting process in the last three years applied and obtained a partial siting license from CNCAN in 2008. In 2009, ...

2009-05-27

297

Comparison of 6 MV and 18 MV photons for IMRT treatment of lung cancer  

International Nuclear Information System (INIS)

Background and purpose: To compare 6 MV and 18 MV photon intensity modulated radiotherapy (IMRT) for non-small cell lung cancer. Materials and methods: Doses for a cohort of 10 patients, typical for our department, were computed with a commercially available convolution/superposition (CS) algorithm. Final dose computation was also performed with a dedicated IMRT Monte Carlo dose engine (MCDE). Results: CS plans showed higher D _9_5_% (Gy) for the GTV (68.13 vs 67.36, p = 0.004) and CTV (67.23 vs 66.87, p = 0.028) with 18 than with 6 MV photons. MCDE computations demonstrated higher doses with 6 MV than 18 MV in D _9_5_% for the PTV (64.62 vs 63.64, p = 0.009), PTV_o_p_t_i_m (65.48 vs 64.83, p = 0.014) and CTV (66.22 vs 65.64, p = 0.027). Dose inhomogeneity was lower with 18 than with 6 MV photons for GTV (0.08 vs 0.09, p = 0.007) and CTV (0.10 vs 0.11, p = 0.045) in CS but not MCDE plans. 6 MV photons significantly (D _3_3_%; p = 0.045) spared the esophagus in MCDE ...

2007-01-01

298

Combustion of refuse-derived fuels in grate and fluidised bed furnaces; Ersatzbrennstoffverbrennung in Rost- und Wirbelschichtoefen  

Energy Technology Data Exchange (ETDEWEB)

In addition to the goal of ensuring waste disposal, thermal waste treatment has always been aimed at the energy-efficient utilisation of wastes. Developments in waste management have led to an increase in high-calorific waste arisings. This is attributable to the use of mechanical-biological waste treatment as well as to segregated waste collection systems. High-calorific wastes are equivalent to fossil fuels in terms of their calorific content. Furthermore, they fulfil the legal requirements for conversion to energy. Another source of high-calorific wastes suitable for conversion to energy can be made available through the segregated disposal of industrial wastes, in many cases at low cost. These high-calorific fractions of varying origin and composition are referred to generically as substitute fuels, a term which implies quality and availability by reference to other fuels. Specifically, the term substitute fuel implies that it can be used for energy production - or conversion - ...

2005-07-01

299

California and western region geothermal heat pump training center  

Energy Technology Data Exchange (ETDEWEB)

The Geothermal Energy Association ({open_quotes}GEA{close_quotes}) will create and manage a Geothermal Heat Pump ({open_quotes}GHP{close_quotes}) Training Center to deliver GHP and HVAC courses throughout California in response to imminent demand driven by national promotion. GEA services include providing management structure, cadre, curricula, promotion and physical equipment. The Center is dedicated to infrastructure strengthening goals of the Geothermal Heat Pump Consortium, Inc. ({open_quotes}GHPC{close_quotes}), the California Energy Commission ({open_quotes}CEC{close_quotes}) and Interagency Geothermal Heat Pump Task Force, and Geothermal Energy Association ({open_quotes}GEA{close_quotes}). Second-half 1996 start-up is co-funded by GHPC, CEC, GEA and three California utilities. Initial support is to five utilities representing 70 percent of California power users. Goals include becoming market driven by year No. 3 and self-finding by year No. 5. AR training ...

1996-12-31

300

Attempting immortality  

Energy Technology Data Exchange (ETDEWEB)

The world`s population of research reactors is growing old. Many have been adapted to serve new purposes over their lives, from testing materials for nuclear power programmes and supporting neutron physics experiments, to colouring gemstones, doping silicon and generating medical isotopes. In the first article of this survey of research reactor issues, Wilfried Krull from GKSS in Germany describes the effects on a reactor of supporting these changes in application as ``design ageing`` . Managing this and other symptoms of ageing to extend plant life is a key task for operators, and Krull discusses the efforts being made internationally to handle them. Eventually, terminal decline of one vital component can determine when a reactor has to be shutdown for refurbishment. For BR2 in Belgium, it was the beryllium matrix. Edgar Koonen from SCK-CEN explains work being done to replace it and extend reactor life for around 15 years. The Triga at the University of Austria`s Atomic Institute has ...

1995-12-01

301

Analysis of log rate noise in Ontario's CANDU reactors  

Energy Technology Data Exchange (ETDEWEB)

In the fall of 2003, the operators noticed that in the recently-refurbished Bruce A Shutdown System no. 1 (SDS1) the noise level in Log Rate signals were much larger than before. At the request of the Canadian Nuclear Safety Commission (CNSC), all Canadian CANDU reactors took action to characterize their Log Rate noise. Staff of the Inspection and Maintenance Services division of Ontario Power Generation (OPG) has collected high-speed high-accuracy noise data from nearly all 16 Ontario reactors, either as part of routine measurements before planned outages or as a dedicated noise recording. This paper gives the results of examining a suitable subset of this data, with respect to the characteristics and possible causes of Log Rate noise. The reactor and instrumentation design is different at each station: the locations of the moderator injection nozzles, the location of the ion chambers for each system, and the design of the Log Rate amplifiers. It was found that ...

2007-07-01

302

After inventory and assessment : what was found out and what was done about it  

International Nuclear Information System (INIS)

Some of the methodologies, techniques, dependencies and lessons learned regarding the year 2000 (Y2K) project currently underway at PanCanadian are described. The Y2K problem, which is a date related malfunction associated with the turn of the century, may affect computers and automated control systems. The cost of fixing this world wide problem ranges from $52 billion to $2 trillion. At PanCanadian, central to ensuring that the entire corporation is ready for the Year 2000 is a dedicated project team in the information technology (IT) department who manage all the life-cycle software for the company. IT staff purchase, install and remove all obsolete software and data. Inventory, testing and remediation of all software, hardware and embedded systems are the basis of the plan of action adopted by the I.T. Y2K project team. Dealing with Y2K problems of business partners, and planning for business interruption are special problems for which different approaches have ...

303

Advantages of magnification in digital phase-contrast mammography using a practical X-ray tube  

Energy Technology Data Exchange (ETDEWEB)

Phase-contrast imaging with a practical cone-beam X-ray tube has been realized for clinical use in digital mammography using computed radiography (CR). To perform phase-contrast imaging, the X-ray detector must be distanced from an object so that the phase-contrast image achieves magnification; in a mammography unit dedicated to phase-contrast imaging, the magnification ratio is 1.75. When using an X-ray tube with a 0.1-mm focal spot, it appears that the penumbra in magnification blurs both projected images and the phase contrast, which generates an edge effect. However, where the sampling pitch of the CR plate is 43.75 {mu}m, the blur stretches the width of the phase contrast so that unit pixels in the detector can capture it. Note that the width of an ideal phase contrast using an X-ray point source results in a phase contrast too narrow for detection with CR. In addition to phase contrast improving image quality, a re-scaling effect increases image sharpness in ...

2008-12-15

304

Advances in human reliability analysis in Mexico  

Energy Technology Data Exchange (ETDEWEB)

Human Reliability Analysis (HRA) is a very important part of Probabilistic Risk Analysis (PRA), and constant work is dedicated to improving methods, guidance and data in order to approach realism in the results as well as looking for ways to use these to reduce accident frequency at plants. Further, in order to advance in these areas, several HRA studies are being performed globally. Mexico has participated in the International HRA Empirical study with the objective of -benchmarking- HRA methods by comparing HRA predictions to actual crew performance in a simulator, as well as in the empirical study on a US nuclear power plant currently in progress. The focus of the first study was the development of an understanding of how methods are applied by various analysts, and characterize the methods for their capability to guide the analysts to identify potential human failures, and associated causes and performance shaping factors. The HRA benchmarking study has been ...

2010-10-15

305

Activities performed within the program of Nuclear Safety Research on structural and cladding materials for innovative reactor systems able to transmute nuclear waste  

International Nuclear Information System (INIS)

Full text: The transmutation of nuclear waste to reduce the burden on a geological repository is a relevant topic within the Program of Nuclear Safety Research of the Research Centre Karlsruhe. Several studies have confirmed that a high efficiency of transmutation of actinides is reached in fast neutron spectrum reactor system. Therefore, an important effort is dedicated to the study of transmutation strategies with different fast reactors and their associated technologies. Moreover, in international contexts as Generation IV International Forum (GIF) and Sustainable Nuclear Energy Technology Platform (SNETP), fast reactors are considered in the frame of sustainable development of nuclear energy and reduction of waste. The systems that are currently under investigation, in the frame of the different fuel cycle scenarios, are liquid metal cooled and gas cooled fast reactors as well as Accelerator Driven Sub-critical Transmutation devices (ADS). These innovative ...

2009-10-05

306

A detailed analysis of the properties of radiolyzed proteinaceous amino acids  

International Nuclear Information System (INIS)

The thermal behaviour of 21 proteinaceous l-amino acids either as pristine samples and also as radiolyzed (3.2 MGy) samples was studied with the differential scanning calorimeter. The onset and peak melting point as well as the melting enthalpy of all samples before and after the radiation treatment was measured and reported. The residual amount of each amino acid survived to the radiation dose of 3.2 MGy (N_#gamma#) was measured from the melting enthalpies before and after radiolysis and hence the radiation resistance of each amino acid has been determined. The radiolysis causes a systematic reduction of the melting enthalpy and a shift of the onset and peak melting point to lower values. It is shown that N_#gamma# does not correlate with the melting points of the amino acids but shows a correlation with the entity of the shift of the melting point peaks occurred after radiolysis. Such correlation instead does not exist between the N_#gamma# parameter and the onset melting points of ...

2011-03-01

307

Use of a convolution/superposition-based treatment planning system for dose calculations in the kilovoltage energy range  

International Nuclear Information System (INIS)

A number of procedures in diagnostic radiology and cardiology make use of long exposures to x-rays from fluoroscopy units. Although numerous studies have been performed to measure or calculate skin dose from these procedures, there have only been a handful of studies to determine the dose to the other organs. This thesis was focused on devising a method to calculate the absorbed dose to underlying tissues and organs. The work was performed in several stages. First, a commercial convolution/superposition-based treatment planning system used in radiation oncology was modified and complemented to make it usable with the low energies of x-rays used in diagnostic radiology. This required generation of energy deposition kernels in the kilovoltage energy range. The kernels were generated using the EGS4 Monte Carlo system of codes and added to the treatment planning system. The treatment planning system was then evaluated for its accuracy of calculations at low energies within homogeneous and ...

2001-03-01

308

The effect of patient shield position on gonad dose during lumbar spine radiography  

Energy Technology Data Exchange (ETDEWEB)

Background: In an effort to standardise radiological practices in the Republic of Ireland, current legislation states that 'written protocols for every type of standard radiological practice shall be established'. In order to fulfil this requirement the Irish Medical Council recommends the protocols issued by the Commission of European Communitees (CEC) for adoption in the country. Whilst this document does provide good guidance with regard to various radiographic factors, patient shielding instructions are notably ambiguous. The aim of this study was to remove some of this ambiguity by defining the optimal method of positioning patient shielding in antero-posterior (AP) and lateral lumbar spine radiographic examinations. These projections were chosen on the basis of their area of coverage being in close to and in some cases including the reproductive organs. They also represent the highest source of collective population dose of any conventional radiographic ...

2010-05-15

309

The effect of patient shield position on gonad dose during lumbar spine radiography  

International Nuclear Information System (INIS)

Background: In an effort to standardise radiological practices in the Republic of Ireland, current legislation states that 'written protocols for every type of standard radiological practice shall be established'. In order to fulfil this requirement the Irish Medical Council recommends the protocols issued by the Commission of European Communitees (CEC) for adoption in the country. Whilst this document does provide good guidance with regard to various radiographic factors, patient shielding instructions are notably ambiguous. The aim of this study was to remove some of this ambiguity by defining the optimal method of positioning patient shielding in antero-posterior (AP) and lateral lumbar spine radiographic examinations. These projections were chosen on the basis of their area of coverage being in close to and in some cases including the reproductive organs. They also represent the highest source of collective population dose of any conventional radiographic examination carried out in ...

2010-05-01

310

Study of X-ray filter and peak kilovoltage in Fuji computed radiography in regard to the detection of simulated pulmonary nodules  

Energy Technology Data Exchange (ETDEWEB)

To determine a suitable combination of X-ray filter and tube kilovoltage for Fuji Computed Radiography (FCR), provide better detection of pulmonary nodules, and reduce patient exposure, we compared observer performance with different X-ray filters and tube voltages. Radiographs were obtained with a copper filter backed by aluminium, with a tungsten filter backed by yttrium and aluminium, and with a lead filter backed by yttrium and aluminium, at both 100 kVp and 135 kVp. Observer performance in detecting simulated lung nodules, which were placed on the posterior aspect of a chest phantom, was compared using receiver operating characteristic (ROC) techniques for each combination of the X-ray filter and tube voltage. The results of the study indicated that (1) nodule detection was superior for the images obtained with 135 kVq as compared with 100 kVp; (2) approximately equal detection rates were obtained for the three X-ray filter sets, although results with the ...

1994-10-01

311

Study of X-ray filter and peak kilovoltage in Fuji computed radiography in regard to the detection of simulated pulmonary nodules  

International Nuclear Information System (INIS)

To determine a suitable combination of X-ray filter and tube kilovoltage for Fuji Computed Radiography (FCR), provide better detection of pulmonary nodules, and reduce patient exposure, we compared observer performance with different X-ray filters and tube voltages. Radiographs were obtained with a copper filter backed by aluminium, with a tungsten filter backed by yttrium and aluminium, and with a lead filter backed by yttrium and aluminium, at both 100 kVp and 135 kVp. Observer performance in detecting simulated lung nodules, which were placed on the posterior aspect of a chest phantom, was compared using receiver operating characteristic (ROC) techniques for each combination of the X-ray filter and tube voltage. The results of the study indicated that 1) nodule detection was superior for the images obtained with 135 kVq as compared with 100 kVp; 2) approximately equal detection rates were obtained for the three X-ray filter sets, although results with the ...

1994-01-01

312

Stochastic risk estimation from medical x-ray diagnostic examinations, 2  

International Nuclear Information System (INIS)

The risks of genetic, leukemia and malignant diseases from medical X-ray diagnostic examinations were estimated using the frequency of radiographic and fluoroscopic exposures per diagnostic examination, child expectancy, leukemia and malignancy significant factors, and using a weighting factor determined on the basis of data concerning the cancer mortality among atomic bomb survivors in Nagasaki and of a recommendation of International Commission of Radiological Protection. The organ or tissue doses with respect to the stochastic risks were determined with ionization chambers and thermoluminescent dosimeters placed at the positions of the organs or tissues in a RANDO woman phantom which was exposed to diagnostic X-rays according to technical factors of typical radiographic and fluoroscopic examinations obtained from a nationwide survey. The resultant risks by age-group and type of radiographic and fluoroscopic examination are tabulated in terms of risk level of ...

1981-01-01

313

Reintrusion of silicic magma chambers by mafic dike complex: evidence from the northern Semail ophiolite  

Energy Technology Data Exchange (ETDEWEB)

Late plagiogranite bodies in the Semail ophiolite have been previously suggested to represent late stage fractionates within an episodic spreading center magma chamber or the roots of seamount chains. Field and lab observations suggest that these late silicic magma chambers represent zones of repeated injection by dikes of intermediate to mafic composition. Multiple generations of intrusion, partial resorption and reintrusion are preserved in the plagiogranite as 1) relict phantom xenoliths, 2) angular xenoliths with quartz-rich margins, 3) deformed fine-grained dikes with distinct chilled margins, and 4) planes of rectangular blocks with cuspate margins or ellipsoids of similar fine grained mafic materials. The blocks and ellipsoids are actually dismembered mafic dikes that chilled by intruding a cooler silicic liquid and were either thermally fractured or pinched out. All of the dikes are hydrothermally altered to assemblages including amph., qtz., epi., preh., ...

1985-01-01

314

Radiation dosimetry of "1"1"1In-oxinate labelled leucocytes  

International Nuclear Information System (INIS)

The patients studied were referred for routine abscess localization with indium-111 labelled autologous leukocytes. One series (n=15) was studied at 1 day after reinjection of labelled cells and a second series (n=9) was studied between 4 hours and 4 days after reinjection of labelled cells. The leukocytes were isolated by a gravity sedimentation method and labelled with In-111 oxinate according to Roevekamp and co-workers. The labelled cell suspension administered to the patient contained between 11 and 15 MegaBq (300-400 microCi). The indium-111 concentration in the liver and spleen was quantitated using a scintillation camera and an on-line computer system. Phantom studies were carried out to obtain conversion factors from geometric mean counts to MegaBq of activity for both liver and spleen. Once determined, the amount of activity in liver and spleen was corrected for physical decay of In-111 and expressed as a percentage of the administered activity. ...

1982-06-25

315

Proceedings of clinical SPECT [single photon emission computed tomography] symposium  

International Nuclear Information System (INIS)

It has been five years since the last in-depth American College of Nuclear Physicians/Society of Nuclear Medicine Symposium on the subject of single photon emission computed tomography (SPECT) was held. Because this subject was nominated as the single most desired topic we have selected SPECT imaging as the basis for this year's program. The objectives of this symposium are to survey the progress of SPECT clinical applications that have taken place over the last five years and to provide practical and timely guidelines to users of SPECT so that this exciting imaging modality can be fully integrated into the evaluation of pathologic processes. The first half was devoted to a consideration of technical factors important in SPECT acquisition and the second half was devoted to those organ systems about which sufficient clinical SPECT imaging data are available. With respect to the technical aspect of the program we have selected the key areas which demand awareness and attention in order ...

1986-09-22

316

Preliminary study of metabolic radiotherapy with {sup 188}Re via small animal imaging  

Energy Technology Data Exchange (ETDEWEB)

{sup 188}Re is a {beta}{sup -} (Emax=2.12 MeV) and {gamma} (155 keV) emitter. Since its chemistry is similar to that of the largely employed tracer, {sup 99m}Tc, molecules of hyaluronic acid (HA) have been labelled with {sup 188}Re to produce a target specific radiopharmaceutical. The radiolabeled compound, i.v. injected in healthy mice, is able to accumulate into the liver after a few minutes. To study the effect of metabolic radiotherapy in mice, we have built a small gamma camera based on a matrix of YAP:Ce crystals, with 0.6x0.6x10 mm{sup 3} pixels, read out by a R2486 Hamamatsu PSPMT. A high-sensitivity 20 mm thick lead parallel-hole collimator, with hole diameter 1.5 mm and septa of 0.18 mm, is placed in front of the YAP matrix. Preliminary results obtained with various phantoms containing a solution of {sup 188}Re and with C57 black mice injected with the {sup 188}Re-HA solution are presented. To increase the space resolution and to obtain two orthogonal ...

2006-01-15

317

Population doses from beam-therapy in Japan, 1978, 3  

International Nuclear Information System (INIS)

As a series of estimations of population doses and of risk estimates from medical exposures in Japan, the malignancy significant dose (MSD) and the fatal malignant risk from beam therapy were estimated based on a nationwide survey of radiotherapeutic treatments, using a malignancy significant factor and a weighting factor determined from the data on the cancer mortality among the atomic bomb survivors in Nagasaki. The effective dose was defined as a sum of the product of the weighting factor and the organ or tissue doses with respect to the malignant diseases. The organ or tissue doses were determined with ionization chambers placed at the positions of their center in a MixDp-phantom simulated lung tissues by a block of cork, using a telecobalt unit, a conventional X-ray unit and a medical linear accelerator. The organ or tissue doses were categorized into three dose components; namely 1) dose from useful beams; 2) scattered radiation dose from irradiated materials ...

1981-01-01

318

Performance study of teleradiology network systems with CRT monitors. ROC analysis of an observation study of simulated lung nodules  

International Nuclear Information System (INIS)

To evaluate the diagnostic performance of commercially available CRT monitors used in a teleradiology system by determining the rate of detection of simulated lung nodules. Three types of CRT monitors were tested in the observation study. They had matrix sizes of 1024 x 768 (16 inches, color), 1024 x 768 (20 inches, color) and 1600 x 1125 (24 inches, black and white). Twenty chest radiographs were obtained by Fuji computed radiography (FCR) of an anthropomorphic chest phantom with ten simulated nodules on its surface. These FCR films were digitized by a film digitizer with 125 DPI (1024 x 1024 matrix sizes) and 12 bit gray scales, and the image data were transferred from Shinshu University Hospital to other hospitals where interpretation was carried out by the radiologists. Ten radiologists of three hospitals were asked to interpret independently both the original FCR films and the images shown on the CRT monitors and to indicate the presence or absence of ...

319

Multidimensional B-spline parameterization of the detection probability of PET systems to improve the efficiency of Monte Carlo simulations  

International Nuclear Information System (INIS)

Accurate modeling of system response and scatter distribution is crucial for image reconstruction in emission tomography. Monte Carlo simulations are very well suited to calculate these quantities. However, Monte Carlo simulations are also slow and many simulated counts are needed to provide a sufficiently exact estimate of the detection probabilities. In order to overcome these problems, we propose to split the simulation into two parts, the detection system and the object to be imaged (the patient). A so-called 'virtual boundary' that separates these two parts is introduced. Within the patient, particles are simulated conventionally. Whenever a photon reaches the virtual boundary, its detection probability is calculated analytically by evaluating a multi-dimensional B-spline that depends on the photon position, direction and energy. The unknown B-spline knot values that define this B-spline are fixed by a prior 'pre-' simulation that needs to be run once for each scanner type. After ...

2010-06-21

320

Monte Carlo-based investigation of effect of inhomogeneity in brachytherapy dose calculation - Part I  

International Nuclear Information System (INIS)

Brachytherapy refers to short distance treatment of cancer with radiation from small, encapsulated radionuclide sources. This type of treatment is given by placing sources directly into or near the volume to be treated. The dose is then delivered continuously, either over a short period of time (temporary implants) or over the lifetime of the source to a complete decay (permanent implants). This technique is extensively used in the treatments of gynecological, breast, prostate, head and neck, and other soft tissue cancers. The clinical outcomes of this treatment depend on accurate dosimetry and dose delivery. The patient is generally considered to be water equivalent. So the treatment planning system software generally is based on measured or calculated dose distributions in homogenous water medium. In real situation, the treatment volume is not homogenous water medium, but it is a heterogeneous medium consisting of bone, soft tissue, lung, air etc. For better understanding we present ...

2009-04-01

321

Monte Carlo treatment planning for photon and electron beams  

International Nuclear Information System (INIS)

During the last few decades, accuracy in photon and electron radiotherapy has increased substantially. This is partly due to enhanced linear accelerator technology, providing more flexibility in field definition (e.g. the usage of computer-controlled dynamic multileaf collimators), which led to intensity modulated radiotherapy (IMRT). Important improvements have also been made in the treatment planning process, more specifically in the dose calculations. Originally, dose calculations relied heavily on analytic, semi-analytic and empirical algorithms. The more accurate convolution/superposition codes use pre-calculated Monte Carlo dose 'kernels' partly accounting for tissue density heterogeneities. It is generally recognized that the Monte Carlo method is able to increase accuracy even further. Since the second half of the 1990s, several Monte Carlo dose engines for radiotherapy treatment planning have been introduced. To enable the use of a Monte Carlo treatment planning (MCTP) dose ...

2007-04-01

322

Monte Carlo simulation and dosimetric verification of radiotherapy beam modifiers  

International Nuclear Information System (INIS)

Monte Carlo simulation of beam modifiers such as physical wedges and compensating filters has been performed with a rectilinear voxel geometry module. A modified version of the EGS4/DOSXYZ code has been developed for this purpose. The new implementations have been validated against the BEAM Monte Carlo code using its standard component modules (CMs) in several geometrical conditions. No significant disagreements were found within the statistical errors of 0.5% for photons and 2% for electrons. The clinical applicability and flexibility of the new version of the code has been assessed through an extensive verification versus dosimetric data. Both Varian multi-leaf collimator (MLC) wedges and standard wedges have been simulated and compared against experiments for 6 MV photon beams and different field sizes. Good agreement was found between calculated and measured depth doses and lateral dose profiles along both wedged and unwedged directions for different depths and focus-to-surface ...

2001-11-01

323

Implementation of FFT convolution and multigrid superposition models in the FOCUS RTP system  

International Nuclear Information System (INIS)

In radiotherapy treatment planning, convolution/superposition algorithms currently represent the best practical approach for accurate photon dose calculation in heterogeneous tissues. In this work, the implementation, accuracy and performance of the FFT convolution (FFTC) and multigrid superposition (MGS) algorithms are presented. The FFTC and MGS models use the same 'TERMA' calculation and are commissioned using the same parameters. Both models use the same spectra, incorporate the same off-axis softening and base incident lateral fluence on the same measurements. In addition, corrections are explicitly applied to the polyenergetic and parallel kernel approximations, and electron contamination is modelled. Spectra generated by Monte Carlo (MC) modelling of treatment heads are used. Calculations using the MC spectra were in excellent agreement with measurements for many linear accelerator types. To speed up the calculations, a number of calculation techniques were implemented, ...

2000-04-01

324

High-resolution "1H magnetic resonance spectroscopy imaging at 1.5 and 3 Tesla of the human brain: development of techniques and applications for patients with primary brain tumors and multiple sclerosis  

International Nuclear Information System (INIS)

The aim of this work was to develop several strategies and software-packages for the evaluation of in-vivo-data of the human brain, which were acquired with high-resolution 1H-MRSI at 1.5 and 3 T. Several studies involving phantoms, volunteers and patients were performed. Quality assurance studies were conducted in order to evaluate the reproducibility of the applied MR-techniques at both field strengths. A qualitative comparison-study between MRSI-data from a 1.5 T clinical MR-scanner and a 3 T research MR-scanner showed the advantages of the more advanced MRSI sequences and higher field strength (3 T). A study involving patients with primary brain tumours (gliomas) was performed in cooperation with the Department of Neurosurgery (University of Erlangen-Nuremberg). The methods developed in the course of this study, such as the integration of MRS-data into a stereotactic-system, the segmentation of metabolic maps and the correlation with histopathological findings ...

325

Estimate of the scatter component in SPECT  

Energy Technology Data Exchange (ETDEWEB)

Analytical expressions that describe the dependence of slopes and amplitudes of the scatter distribution functions (SDF) on source depth and media density are used to estimate a scatter component in SPECT projection data. Since the ratio of detected scattered to total photons (S/T), SDF amplitude and slope depend strongly on line source length (SL) used to obtain SDFs, we compared estimated scattered components using SDFs, obtained for lengths of 2-21 cm. At 10 cm source depth, S/T changes from 0.19 to 0.36 when SL changes from 2 to 21 cm. Scatter amplitude`s dependence on source depth (d) in water was described by 6.38e{sup -0.186d} for a 2 cm and 16.15e{sup -0.129d} for a 21 cm SL. Slope was described by 0.292d{sup -0.601} for a cm SL and by 0.396d{sup -0.82} for a 21 cm SL. The estimated scatter components are compared with simulated SPECT projection data obtained with Monte Carlo modeling of six hot spheres placed in a cylindrical water filled phantom. The ...

1996-12-31

326

Collective effective dose equivalent, population doses and risk estimates from occupational exposures in Japan  

Energy Technology Data Exchange (ETDEWEB)

Collective dose equivalent and population dose from occupational exposures in Japan, 1988 were estimated on the basis of a nationwide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 0.21 million workers except for the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the official report of the Japan Nuclear Safety Commission. The total number of workers including nuclear power stations was estimated to be about 0.26 million. Radiation works were subdivided as follows: medical works including dental; non-atomic energy industry; research and education; atomic energy industry and nuclear power station. For the determination of effective dose equivalent and population dose, organ or tissue doses were measured with a phantom experiment. The resultant doses were compared with the doses previously calculated using a chord length technique and ...

1993-05-01

327

Collective effective dose equivalent, population doses and risk estimates from occupational exposures in Japan  

International Nuclear Information System (INIS)

Collective dose equivalent and population dose from occupational exposures in Japan, 1988 were estimated on the basis of a nationwide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 0.21 million workers except for the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the official report of the Japan Nuclear Safety Commission. The total number of workers including nuclear power stations was estimated to be about 0.26 million. Radiation works were subdivided as follows: medical works including dental; non-atomic energy industry; research and education; atomic energy industry and nuclear power station. For the determination of effective dose equivalent and population dose, organ or tissue doses were measured with a phantom experiment. The resultant doses were compared with the doses previously calculated using a chord length technique and ...

1993-01-01

328

Canon's flat-panel detector  

International Nuclear Information System (INIS)

We measured and evaluated digital, pre-sampling and overall imaging properties (characteristic curve, modulation transfer function (MTF), Wiener spectrum (WS), noise equivalent quanta (NEQ)) for Cannon's flat-panel detector (FPD), Fuji computed radiography (FCR) and screen-film (S/F) systems, respectively. First, the digital and overall characteristic curves of FPD and FCR systems were more wide dynamic range than that of the S/F system. Second, the pre-sampling and overall MTF of FPD system were better than those of FCR system a little at lower spatial frequencies than 0.8 mm"-"1, but the overall MTF of FPD and FCR systems were worse than that of S/F system a little at all spatial frequencies. Third, the digital and overall WS of FPD system were similar or better than those of FCR system, but the overall WS of FPD and FCR systems were worse than that of S/F system. Fourth, the pre-sampling and overall NEQ of FPD system were better than those of FCR system a little at lower spatial ...

2002-12-01

329

Canon's flat-panel detector  

Energy Technology Data Exchange (ETDEWEB)

We measured and evaluated digital, pre-sampling and overall imaging properties (characteristic curve, modulation transfer function (MTF), Wiener spectrum (WS), noise equivalent quanta (NEQ)) for Cannon's flat-panel detector (FPD), Fuji computed radiography (FCR) and screen-film (S/F) systems, respectively. First, the digital and overall characteristic curves of FPD and FCR systems were more wide dynamic range than that of the S/F system. Second, the pre-sampling and overall MTF of FPD system were better than those of FCR system a little at lower spatial frequencies than 0.8 mm{sup -1}, but the overall MTF of FPD and FCR systems were worse than that of S/F system a little at all spatial frequencies. Third, the digital and overall WS of FPD system were similar or better than those of FCR system, but the overall WS of FPD and FCR systems were worse than that of S/F system. Fourth, the pre-sampling and overall NEQ of FPD system were better than those of FCR system a little at ...

2002-12-01

330

ANALYSIS OF ACCELERATOR BASED NEUTRON SPECTRA FOR BNCT USING PROTON RECOIL SPECTROSCOPY  

Energy Technology Data Exchange (ETDEWEB)

Boron Neutron Capture Therapy (BNCT) is a promising binary treatment modality for high-grade primary brain tumors (glioblastoma multiforme, GM) and other cancers. BNCT employs a boron-10 containing compound that preferentially accumulates in the cancer cells in the brain. Upon neutron capture by {sup 10}B energetic alpha particles and triton released at the absorption site kill the cancer cell. In order to gain penetration depth in the brain Fairchild proposed, for this purpose, the use of energetic epithermal neutrons at about 10 keV. Phase I/II clinical trials of BNCT for GM are underway at the Brookhaven Medical Research Reactor (BMRR) and at the MIT Reactor, using these nuclear reactors as the source for epithermal neutrons. In light of the limitations of new reactor installations, e.g. cost, safety and licensing, and limited capability for modulating the reactor based neutron beam energy spectra alternative neutron sources are being contemplated for wider implementation of this ...

1998-11-06

331

A study on the mineral density of the lumbar vertebral bone in children of metabolic disorders and control using single energy quantitative CT  

Energy Technology Data Exchange (ETDEWEB)

A cross sectional study on the mineral density of the 3rd lumbar vertebral trabecular bone was carried out in 123 children less than 15 years old, comprising 44 controls, and 79 patients affected with conditions which are at risk for developing metabolic derangement of skeletal bone (34 patients taking antiepileptic drugs (AED), 29 undergoing glucocorticoid (GC) therapy and 16 bedridden patients), by using quantitative computed tomography (QCT) with a CaCO{sub 3} phantom. Serum Ca and alkaline-phosphatase (Alp) levels were measured at the time of QCT examinations in all. The results obtained were as follows: The QCT values in the control children showed neither age dependency nor a sexual difference before puberty. The QCT values in each group showed significant difference with one another; the control group>the AED group>the GC group>the bedridden group (p<0.05{approx}0.005). The serum Ca levels in each pathology group were significantly lower than ...

1991-06-01

332

A revised dosimetric model of the adult head and brain  

Energy Technology Data Exchange (ETDEWEB)

During the last decade, new radiopharmaceutical have been introduced for brain imaging. The marked differences of these tracers in tissue specificity within the brain and their increasing use for diagnostic studies support the need for a more anthropomorphic model of the human brain and head. Brain and head models developed in the past have been only simplistic representations of this anatomic region. For example, the brain within the phantom of MIRD Pamphlet No. 5 Revised is modeled simply as a single ellipsoid of tissue With no differentiation of its internal structures. To address this need, the MIRD Committee established a Task Group in 1992 to construct a more detailed brain model to include the cerebral cortex, the white matter, the cerebellum, the thalamus, the caudate nucleus, the lentiform nucleus, the cerebral spinal fluid, the lateral ventricles, and the third ventricle. This brain model has been included within a slightly modified version of the head ...

1996-06-01

333

A revised dosimetric model of the adult head and brain  

International Nuclear Information System (INIS)

During the last decade, new radiopharmaceutical have been introduced for brain imaging. The marked differences of these tracers in tissue specificity within the brain and their increasing use for diagnostic studies support the need for a more anthropomorphic model of the human brain and head. Brain and head models developed in the past have been only simplistic representations of this anatomic region. For example, the brain within the phantom of MIRD Pamphlet No. 5 Revised is modeled simply as a single ellipsoid of tissue With no differentiation of its internal structures. To address this need, the MIRD Committee established a Task Group in 1992 to construct a more detailed brain model to include the cerebral cortex, the white matter, the cerebellum, the thalamus, the caudate nucleus, the lentiform nucleus, the cerebral spinal fluid, the lateral ventricles, and the third ventricle. This brain model has been included within a slightly modified version of the head ...

1996-07-21

334

A gradient feature weighted Minimax algorithm for registration of multiple portal images to 3DCT volumes in prostate radiotherapy  

International Nuclear Information System (INIS)

Purpose: To develop an accurate, fast, and robust algorithm for registering portal and computed tomographic (CT) images for radiotherapy using a combination of sparse and dense field data that complement each other. Methods and Materials: Gradient Feature Weighted Minimax (GFW Minimax) method was developed to register multiple portal images to three-dimensional CT images. Its performance was compared with that of three others: Minimax, Mutual Information, and Gilhuijs' method. Phantom and prostate cancer patient images were used. Effects of registration errors on tumor control probability (TCP) and normal tissue complication probability (NTCP) were investigated as a relative measure. Results: Registration of four portals to CTs resulted in 30% lower error when compared with registration with two portals. Computation time increased by nearly 50%. GFW Minimax performed the best, followed by Gilhuijs' method, the Minimax method, and Mutual Information. Conclusions: ...

2006-06-01

335

Verification of the CFD code FLUENT by post test calculation of ROCOM experiments  

International Nuclear Information System (INIS)

Full text of publication follows: The TUV NORD e.V. is an independent Technical Support Organisation (TSO) performing safety assessments in almost every field of technology. In nuclear safety the TUV can look back on more than 40 years of experience. In the last years in Germany PWR safety analyses were focussed on boron dilution events with the potential of reactivity transients. The possibility of coolant with a low boron concentration collected in localized areas of the reactor coolant system (RCS) can be caused by injection of coolant with less boron content from interfacing systems (external dilution) as well as separation of borated reactor coolant into highly concentrated and diluted fractions (inherent dilution). Inherent dilution can e.g. occur after reflux-condenser heat transfer after a small break loss of coolant accident (SBLOCA) with a limited operability of the emergency core cooling (ECC) systems. The TUV Nord e.V. was charged by German supervisory authorities with the ...

2005-10-02

336

The Hubble Space Telescope Wide Field Camera 3 Early Release Science Data: Panchromatic Faint Object Counts From 0.2-2 Micron To Ab=26-27 Mag  

Science.gov (United States)

We describe the Hubble Space Telescope (HST) Wide Field Camera 3 (WFC3) Early Release Science (ERS) observations in the GOODS-South field. The new WFC3 ERS data provide calibrated, drizzled mosaics with FHWM=0.07--0.15" in the near-UV (filters F225W, F275W, and F336W) and near-IR (F098W, F125W, and F160W) in typically 2 orbits per filter. Together with the existing HST/ACS GOODS-S mosaics in the BVi'z' filters, the 10-band ERS data cover 40-50 sq. arcmin to AB=26-27.0 mag (10-sigma for point sources). In this poster, we describe the: (1) scientific rationale, data taking and reduction procedures of the WFC3 ERS mosaics; (2) object cataloging and star-galaxy separation techniques used in these 10 different filters; (3) reliability and completeness of the 10-band object catalogs from the ERS mosaics; (4) object counts in 10 different filters from 0.2-1.7 microns to AB=26.0-27.0 mag; and (5) the full-color 10-band ERS images. We discuss the panchromatic structure for a variety of ...

2010-01-01

337

Nuclear fuel cycle options  

International Nuclear Information System (INIS)

Presently, industrial maturity can be claimed for two fuel cycle strategies, viz. the 'Once Through Fuel Cycle' (OTC), and the 'Reprocessing Fuel Cycle' (RFC) in which plutonium and very limited uranium quantities are being recycled. It is helpful to recall some key data that set the stage for any discussion of fuel cycle options: 1. Worldwide, the annual spent fuel discharge is in the range of 10500-11000 t heavy-metal (HM), while the industrial reprocessing capacity amounts to #approx# 5000 t HM (OECD NUCLEAR ENERGY AGENCY, Accelerator-driven Systems (ADS) and Fast Reactors (FR) in Advanced Nuclear Fuel Cycles: a Comparative Study, Paris, 2002). Hence, less than 1/2 of the discharged spent fuel can be processed. 2. Worldwide, the cumulative inventory of stored spent fuel is estimated to be #approx# 190000 t HM, and the amount of reprocessed spent fuel is estimated to be #approx# 70000 t HM. The latter inventory has been transformed into high-level waste (HLW) and spent light water ...

2010-10-01

338

New procedures. Comprehensive staging of lung cancer by MRI; Neue Verfahren. Umfassendes Staging des Lungenkarzinoms mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

Lung cancer staging according to the TNM system is based on morphological assessment of the primary cancer, lymph nodes and metastases. All aspects of this important oncological classification are measurable with MRI. Pulmonary nodules can be detected at the clinically relevant size of 4-5 mm in diameter. The extent of mediastinal, hilar and supraclavicular lymph node affection can be assessed at the same time. The predominant metastatic spread to the adrenal glands and spine can be detected in coronal orientation during dedicated MRI of the lungs. Search focused whole body MRI completes the staging. Various additional MR imaging techniques provide further functional and clinically relevant information during a single examination. In the oncological context the most important techniques are imaging of perfusion and tumor motion. Functional MRI of the lungs complements the pure staging and improves surgical approaches and radiotherapy planning. (orig.) [German] Das ...

2010-08-15

339

Energy from wood - part 3: automatic wood furnaces; Holzenergie, Teil 3: automatische Holzfeuerungen - Energie du bois, Partie 3: installations automatiques de chauffage au bois  

Energy Technology Data Exchange (ETDEWEB)

The paper gives an overview on the technologies and applications of automatic wood furnaces. The combustion systems are defined by the flow condition: With increasing gas velocity, fixed bed, stationary fluidized bed (SFB), circulating fluidized bed (CFB), and entrained flow reactors are distinguished. The furnace design and typical applications are described. Further, a comparison is presented which gives data of the typical size range and fuel types for the different combustion systems. The most common fixed bed reactors are under-stoker and grate furnaces. While under-stoker furnaces are applied in the size range from 20 kW to 2.5 MW, grate furnaces cover the size range from a few 100 kW up to more than 50 MW. Under-stoker furnaces are well suited for wood fuel with low ash content, moderate water content and limited fuel size. Grate furnaces are also suited for fuel with high ash and water content and large fuel sizes. Hence grate furnaces are nowadays most common. Due to the ...

2001-07-01

340

Development of a Novel Efficient Solid-Oxide Hybrid for Co-generation of Hydrogen and Electricity Using Nearby Resources for Local Application  

Energy Technology Data Exchange (ETDEWEB)

Developing safe, reliable, cost-effective, and efficient hydrogen-electricity co-generation systems is an important step in the quest for national energy security and minimized reliance on foreign oil. This project aimed to, through materials research, develop a cost-effective advanced technology cogenerating hydrogen and electricity directly from distributed natural gas and/or coal-derived fuels. This advanced technology was built upon a novel hybrid module composed of solid-oxide fuel-assisted electrolysis cells (SOFECs) and solid-oxide fuel cells (SOFCs), both of which were in planar, anode-supported designs. A SOFEC is an electrochemical device, in which an oxidizable fuel and steam are fed to the anode and cathode, respectively. Steam on the cathode is split into oxygen ions that are transported through an oxygen ion-conducting electrolyte (i.e. YSZ) to oxidize the anode fuel. The dissociated hydrogen and residual steam are exhausted from the SOFEC cathode and then separated by ...

2009-06-30

341

Data Center Energy Benchmarking: Part 3 - Case Study on an ITEquipment-testing Center (No. 20)  

Energy Technology Data Exchange (ETDEWEB)

The data center in this study had a total floor area of 3,024 square feet (ft{sup 2}) with one-foot raised-floors. It was a rack lab with 147 racks, and was located in a 96,000 ft{sup 2} multi-story office building in San Jose, California. Since the data center was used only for testing equipment, it was not configured as a critical facility in terms of electrical and cooling supply. It did not have a dedicated chiller system but was served by the main building chiller plant and make-up air system. Additionally it was served by only a single electrical supply with no provision for backup power in the event of a power outage. The Data Center operated on a 24 hour per day, year-round cycle, and users had full-hour access to the data center facility. The study found that data center computer load accounted for 15% of the overall building electrical load, while the total power consumption attributable to the data center including allocated cooling load and lighting was ...

2007-07-01

342

Coupled effects of the precipitation of secondary species on the mechanical behaviour and chemical degradation of concretes; Les effets couples de la precipitation d'especes secondaires sur le comportement mecanique et la degradation chimique des betons  

Energy Technology Data Exchange (ETDEWEB)

Sulfate attack of cement-based materials remains an important problem for the durability assessment of containers and disposal engineering barriers dedicated to the long-term storage of radioactive wastes since underground water which may reach these elements contains small quantities of sulfates (7-31 mmol/1). This work contributes to the study of sulfate-induced damage mechanisms, to their understanding and modelling. The experimental phases of this study aimed at the understanding of the different physico-chemical phenomena involved during an external sulfate attack at following their evolution and their impact on the transport and mechanical properties of the material. Leaching experiments in pure water and in a solution of sodium sulfate (with a sulfate content of 15 mmol/1), have been performed simultaneously on OPC paste (w/c 0,4)in order to allow a comparison of test results. The frequent analysis of the leachant has shown a consumption of sulfate ions by ...

2002-06-01

343

Comparison of high resolution whole-body MRI using parallel imaging and PET-CT. First experiences with a 32-channel MRI system  

International Nuclear Information System (INIS)

To compare the accuracy in the detection and staging of various malignant tumors with high resolution whole-body MRI using parallel imaging with whole-body dual-modality PET-CT. Preliminary results of an interim analysis from a prospective, blinded study are presented, in which 20 patients (mean age 59 years, range 27-77 years) with different oncological diseases underwent whole-body dual modality FDG-PET-CT screening for tumor search or staging in case of confirmed or suspected metastatic disease. All patients also underwent whole-body MRI imaging with the use of parallel imaging (iPAT). High-resolution coronal T1w- and STIR-sequences of 5 body levels with 512 x 512 matrix, axial fast T2w imaging of lung and abdomen (HASTE), contrast-enhanced dynamic and static T1w-sequences of liver, brain, abdomen, and pelvis were performed. Using a 32-channel whole-body MRI scanner (Magnetom Avanto, Siemens Medical Solutions) with a total field of view of 205 cm and free table movement, all ...

344

Application of a gamma spectroscopy system to the measurement of neutron cross sections necessary to the development of nuclear energy; Mise au point d'un systeme de spectroscopie pour mesurer des sections efficaces neutroniques applicables a un possible developpement du nucleaire comme source d'energie  

Energy Technology Data Exchange (ETDEWEB)

This work concerns the development of nuclear energy and nuclear waste management in particular. Two parts of this study can be distinguished. In the first part (theoretical), a thorium-plutonium fuel based on MOX and dedicated for PWR was investigated in order to transmute plutonium in a potentially low waste fuel cycle. It was shown that this type of fuel is not regenerative but could be used for a transition to the industrial thorium fuel cycle without building new reactors. Thanks to moderated neutron spectra and high loaded actinide mass in the core, U-233 is quickly created ({approx}300 kg/y) for a loss of about {approx}1200 kg of fissile plutonium. In the second part (experimental), we have developed and built a new reaction chamber to measure neutron cross sections of actinides by alpha-gamma spectroscopy. This experimental device (in principle transportable) was commissioned in the high flux reactor of ILL Grenoble. Neutron flux was measured by gamma ...

2002-09-01

345

The study of technical error analysis on BMD using DEXA  

International Nuclear Information System (INIS)

This study was conducted to search for the type of technical error in DEXA (dual-energy X-ray absorptiometry) and the effect of error to measurement of BMD. The changes of BMD (g/cm2, T-score) by patients information (Age, Weight, Height, Manopause age) input error and Confirming ROI error were investigated. Using spine phantom, we canned 10 times by age (5, 10), weight (10, 20 kg), height (5, 10 cm), manopause age (5, 10) increase and decrease respectively. Scanning region (L-spine, femur, Forearm) of 10 patients was calculated by changing ROI respectively. Analysis of difference for mean (precision 1%) were carried out. There error of patient information (Age, Weight, Height, Manopause age) was not changed differently. In confirming ROI, the BMD and T-score of L-spine involving T-12 was decreased to 0.063 g/cm2, 0.3 and involving L-5 increased to 0.077 g/cm2, 0.5. In narrowing 1 cm of vertical line of ROI, the BMD and T-score decreased to 0.006 g/cm2, 0.1 and in ...

2006-12-01

346

In vitro examination of the visibility of 11 stent catheters with real-time MR imaging; In-vitro-Untersuchung der Sichtbarkeit von 11 Stentkathetern unter Echtzeit-MR-Kontrolle  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluated artifacts of unexpended stents and to determine their exact position for MR-guided percutaneous transluminal angioplasty using real-time sequences. Materials and Methods: By using an in vitro model, 11 unexpended stents - 9 nitinol, 1 stainless steel, and 1 cobalt alloy - were investigated by MR. Each stent was studied in a vessel-phantom filled with saline solution. Imaging was performed using five different realtime sequences: fast low angle shot (Flash 2D), fast imaging with steady precession (true FISP, FISP, interactive true FISP) and segmented echo planar imaging (seg. EPI). Artifacts of the introducer system and the stent were calculated by four blinded radiologists (scale: 1 - artifacts, making an excellent contribution to visualization; 2 - artifacts, making mainly a contribution to visualization; 3 - artifacts, making no contribution to visualization). Furthermore, an evaluation of the visibility of the tip of the stent-catheter and ...

2004-09-01

347

Digital image intensifier radiography: first experiences with the DSI (Digital Spot Imaging); Moeglichkeiten der digitalen Bildverstaerkerradiographie am Beispiel des Digital Spot Imaging (DSI)  

Energy Technology Data Exchange (ETDEWEB)

We performed a comparative study of digitally and conventionally acquired images in gastrointestinal examinations. Radiation dose and spatial resolution were determined in a water phantom. In 676 examinations with either conventional or digital imaging (system: Diagnost 76, DSI) the number of images and the duration of the fluoroscopy time were compared. 101 examinations with digital as well as conventional documentation were evaluated by using 5 criteria describing the diagnostic performance. The entrance dose of the DSI is 12% to 36% of the film/screen system and the spatial resolution of the DSI may be better than that of a film/screen system with a speed of 200. The fluoroscopy time shows no significant difference between DSI and the film/screen technique. In 2 of 4 examination modes significantly more images were produced by the DSI. With exception of the criterion of edge sharpness, DSI yields a significantly inferior assessment compared with the film/screen ...

1995-10-01

348

A deterministic partial differential equation model for dose calculation in electron radiotherapy  

International Nuclear Information System (INIS)

High-energy ionizing radiation is a prominent modality for the treatment of many cancers. The approaches to electron dose calculation can be categorized into semi-empirical models (e.g. Fermi-Eyges, convolution-superposition) and probabilistic methods (e.g. Monte Carlo). A third approach to dose calculation has only recently attracted attention in the medical physics community. This approach is based on the deterministic kinetic equations of radiative transfer. We derive a macroscopic partial differential equation model for electron transport in tissue. This model involves an angular closure in the phase space. It is exact for the free streaming and the isotropic regime. We solve it numerically by a newly developed HLLC scheme based on Berthon et al (2007 J. Sci. Comput. 31 347-89) that exactly preserves the key properties of the analytical solution on the discrete level. We discuss several test cases taken from the medical physics literature. A test case with an academic ...

2010-07-07

349

64-slice multidetector coronary CT angiography: in vitro evaluation of 68 different stents  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to test a large sample of different coronary artery stents using four image reconstruction approaches with respect to lumen visualization, lumen attenuation, and image noise in 64-slice multidetector-row computed tomography (MDCT) in vitro and to provide a catalogue of currently used coronary artery stents when imaged with state-of the-art MDCT. We examined 68 different coronary artery stents (57 stainless steel, four cobalt-chromium, one cobalt-alloy, two nitinol, four tantalum) in a coronary artery phantom (vessel diameter 3 mm, intravascular attenuation 250 HU, extravascular density -70). Stents were imaged in axial orientation with standard parameters: 32x0.6 collimation, pitch 0.24, 680 mAs, 120 kV, rotation time 0.37 s. Four different image reconstructions were obtained with varying convolution kernels and section thicknesses: (1) soft, 0.6 mm, (2) soft, 0.75, (3) medium soft, 0.6, and (4) stent-optimized sharp, 0.6. To evaluate ...

2006-04-15

350

Stent placement under real-time MR control: first experience in an animal model; Stentplazierung unter Echtzeit-MR-Kontrolle: erste tierexperimentalle Erfahrungen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: The aim of this study was to test the feasibility of iliac artery stent placement under MR guidance with real-time MR radial scanning in an animal model. Materials and methods: The experiments were performed on three pigs in a 1.5 T scanner. Radial scanning with a gradient echo technique (T{sub R} 8.4 ms, T{sub E} 3.6 ms, flip angle 10 ) was used. A dedicated backprojector performed the reconstruction of the raw data in real-time. The resulting MR-images were displayed on LCD screens beside the magnet. The sliding window reconstruction technique allowed image acquistion at a frame rate of 16 images per second. MR-compatible self-expanding stents with a diameter of 8 mm and a length of 3 cm were placed into the left iliac artery. Their positions were verified by digital subtraction angiography (DSA) and compared to MRI. Results: All stents were successfully placed. Stent positions as monitored by real-time MR were identical to those seen on DSA images. The ...

1998-12-01

351

Large eddy simulation based fire modeling applications for Indian nuclear power plant  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows: The Nuclear Power Plants (NPPs) are always designed for the highest level of safety against postulated accidents which may be initiated due to internal or external causes. One of the external/internal causes, which may lead to accident in the reactor and its associated systems, is fire in certain vital areas of the plant. Conventionally, the fire containment approach and/or the fire confinement approach is used in designing the fire protection systems of NPPs. Indian NPPs (PHWRs) follow the combined approach to ensure plant safety and all newly designed plants are required to comply with the provisions of Atomic Energy Regulatory Board (AERB) fire safety Guide. In respect of older plants, the reassessment of adequacy of fire safety provisions in the light of current advances has becomes essential so as to decide upon the steps for retrofitting. Keeping this in mind the deterministic fire hazard analysis was carried out for the Madras Atomic Power ...

2005-07-01

352

FEBEX II Project Final report on thermo-hydro-mechanical laboratory tests  

International Nuclear Information System (INIS)

The results of the thermo-hydro-mechanical (THM) study of the FEBEX bentonite performed during FEBEX II are presented. The laboratory test program continued in part with the works carried out during FEBEX I, particularly in activities related to tests aimed to the calibration of the models, the acquisition of parameters by back-analysis and the improvement of the knowledge on the behaviour of expansive clays. But the program has also included tests on new areas: investigations about the influence of the microstructure changes in bentonite, of temperature and of the solute concentration on the behaviour of clay. Besides, several tests were proposed in order to understand the unexpected behaviour observed in the mock-up test, towards the end of year 2. Temperature effects on water retention curves in confined and unconfined conditions were determined, and swelling pressure, hydraulic conductivity and swelling and consolidation strains as a function of temperature were successfully ...

353

Differential diagnosis of rheumatic diseases; Differenzialdiagnose rheumatischer Erkrankungen  

Energy Technology Data Exchange (ETDEWEB)

Which imaging modalities are appropriate for the Differential diagnosis of Rheumatic diseases. MRI has far most the highest sensitivity and is unequaled in its brilliant presentation of Anatomy and Pathology. But it is sometimes forgotten, that this is at least in part the result of carefully selected sequences, dedicated to the expected result. In a method totally independent of any result, this should not be the case. In contrary this method should be highly standardised and regardless what will be the findings. This is true for Plain X-ray. It will be shown, that already the outer silhouette of the soft parts with different features of swelling, and differences in density and even more - defects or appositions of the bony silhouette in the majority of cases at least will allow to classify the patient for a group of diseases and in many cases will lead to a definite diagnosis. Differential diagnoses like Rheumatoid Arthritis versus Psoriatic Arthritis or simply ...

2006-05-15

354

Retrospective individual dosimetry using luminescence and EPR after radiation accidents  

International Nuclear Information System (INIS)

In areas where radiation dose monitoring has not been performed, it is essential to use material available in the environment be able to rapidly assess doses to individuals for immediate emergency medical care or for general estimation of the radiological consequences. It was shown that certain types of telephone cards containing microchips have the potential to be used as individual radiation dosimeters in emergency situations to detect doses over 250 mGy by luminescence measurements. In order to understand the dosimetric properties of chip cards, the components obtained from INFINIEON Company at various stages of production were used for luminescence measurements. It is found that the protecting layer used above the chips so called 'globe top' is the main source of radiation induced signal in chip cards. The globe top produced by INFINIEON at that stage is found to contain SiO2 and Epoxy. In order to improve the dosimetric properties of the chip cards, the raw material of the globe ...

355

MR-based volumetric analysis of small tumor volumes: accuracy of phantom examinations of simulated eye tumors; Evaluierung der MR-Volumetrie kleiner Volumina am Beispiel von Augentumoren mittels Phantomuntersuchungen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: The determination of tumor volume in ocular tumors is very important for the planning and success of radiation therapy. This study uses an animal model to evaluate the accuracy of MR-based volumetry of ocular tumors. Materials and methods: In a total of 25 porcine eyes obtained from the slaughterhouse, ocular tumors were produced by injecting a mixture of hand creme and Gd-DTPA under ophthalmoscopic guidance. The injected volume varied between 0.05 ml and 2.7 ml. The eyes were examined with a 1.5 Tesla scanner and a 4 cm circular surface coil especially developed for ocular MRI. After data transfer to a separate workstation, volumetric analysis was carried out by three independent radiologists using semiautomated software. The determined volume was compared with the injected volume. Results: Of the 25 prepared porcine eyes, 23 were suitable for volumetric analysis. The injection of the mixture of hand creme and GD-DTPA produced two different types of tumors. ...

2003-07-01

356

Concepts of radiotherapy treatment planning  

International Nuclear Information System (INIS)

Full text: Radiotherapy treatment planning (RTP) relies heavily on medical imaging. Until recently, the most important planning tool was the treatment simulator. The kilovoltage radiographic capabilities in a treatment simulator enabled the boundaries of treatment fields to be visualized with respect to bony anatomic landmarks. Perhaps the most important advance in treatment planning in recent years is the ability to visualize the passage of the beams with respect to a more accurate geometrical representation of the tumor and other soft tissue structures. This 'virtual simulation' uses a computer-based representation of a patient to determine the extent of the disease and the location of radiation sensitive normal tissue. Computer tomographic (CT) imaging produces a high-resolution three-dimensional representation of anatomy that can be correlated with other image sets such as magnetic resonance images (MRI) of function. Positron emission tomographic (PET) imaging is beginning to be ...

2000-12-01

357

Phase 2 Final Report. IAEA Safeguards: Implementation blueprint of commercial satellite imagery  

International Nuclear Information System (INIS)

This document - IAEA Safeguards: Implementation Blueprint of Commercial Satellite Imagery - constitutes the second report from SSC Satellitbild giving a structured view and solid guidelines on how to proceed with a conceivable implementation of satellite imagery to support Safeguards activities of the Agency. This Phase 2 report presents a large number of concrete recommendations regarding suggested management issues, work organisation, imagery purchasing and team building. The study has also resulted in several lists of actions and preliminary project plans with GANT schedules concerning training, hardware and software, as well as for the initial pilot studies. In both the Phase 1 and Phase 2 studies it is confirmed that the proposed concept of a relatively small Imagery Unit using high-resolution data will be a sound and feasible undertaking. Such a unit capable of performing advanced image processing as a tool for various safeguard tasks will give the Agency an effective instrument ...

1989-08-01

358

ITWG - A platform for international cooperation in nuclear forensics  

International Nuclear Information System (INIS)

Reporting of the first nuclear trafficking incidents began in the early 1990's. The incidents were handled on a national level, using the resources and expertise available in the respective states. However, it soon became evident that fighting this illicit movement of nuclear material across borders would require international cooperation and a systematic and methodological approach. To this end, the G-8 states encouraged the creation of a dedicated group of experts. The Nuclear Smuggling International Technical Working Group (ITWG) was created in the mid 1990's under the auspices of the G-8, following the 1995 Ottawa summit and the 1996 nuclear security summit held in Moscow. The group reports regularly to the Nuclear Safety and Security Group (NSSG) of the G-8. The ITWG has been working towards a sustainable mechanism to help resolve the international problem surrounding combating the illicit trafficking of nuclear material. In consequence, the technical focus ...

359

Comparison of high resolution whole-body MRI using parallel imaging and PET-CT. First experiences with a 32-channel MRI system; Hochaufloesendes Ganzkoerpertumorstaging unter Verwendung paralleler Bildgebung im Vergleich zur PET-CT. Erste Erfahrungen auf einem 32-Kanal-MRT-System  

Energy Technology Data Exchange (ETDEWEB)

To compare the accuracy in the detection and staging of various malignant tumors with high resolution whole-body MRI using parallel imaging with whole-body dual-modality PET-CT. Preliminary results of an interim analysis from a prospective, blinded study are presented, in which 20 patients (mean age 59 years, range 27-77 years) with different oncological diseases underwent whole-body dual modality FDG-PET-CT screening for tumor search or staging in case of confirmed or suspected metastatic disease. All patients also underwent whole-body MRI imaging with the use of parallel imaging (iPAT). High-resolution coronal T1w- and STIR-sequences of 5 body levels with 512 x 512 matrix, axial fast T2w imaging of lung and abdomen (HASTE), contrast-enhanced dynamic and static T1w-sequences of liver, brain, abdomen, and pelvis were performed. Using a 32-channel whole-body MRI scanner (Magnetom Avanto, Siemens Medical Solutions) with a total field of view of 205 cm and free table movement, all ...

2004-09-01