WorldWideScience
1

Application of 18F-fluorodeoxyglucose positron emission tomography to detection of proximal lesions of obstructive colorectal cancer  

International Nuclear Information System (INIS)

In cases of obstructive colorectal cancer (CRC), preoperative diagnosis of the proximal lesion is often difficult when the primary lesion impedes the passage of the endoscope. The aim of this study was to evaluate the usefulness of fluorine-18-fluorodeoxyglucose positron emission tomography (FDG-PET) in such cases. A total of 52 obstructive CRC patients who underwent preoperative FDG-PET and subsequent surgical resection were retrospectively reviewed. The correlation between characteristics of the proximal lesion and FDG-PET findings was analyzed statistically. There was a significant correlation between the proximal lesion size and the maximum standardized uptake value (P=0.00016). Abnormal FDG accumulation in the proximal colon indicated the existence of proximal cancer or adenoma with a sensitivity of 50% and a specificity of 100%. There was a significant difference in the distribution of tumor size between the cases with proximal abnormal ...

2010-10-01

2

Single photon emission tomography of the pituitary: preliminary communication.  

UK PubMed Central (United Kingdom)

A specific application of single photon emission tomography to the relative quantitation of the pituitary region is described together with the results obtained in 19 patients with pituitary adenoma...Full Text Available

1981-09-01

4

Limitations of Tc99m-MIBI-SPECT Imaging Scans in Persistent Primary Hyperparathyroidism  

UK PubMed Central (United Kingdom)

BackgroundIn primary hyperparathyroidism (PHPT) the predictive value of technetium 99m sestamibi single emission computed tomography (Tc99m-MIBI-SPECT) for localizing pathological...Full Text Available

2011-01-01

5

Iofetamine I 123 single photon emission computed tomography is accurate in the diagnosis of Alzheimer's disease  

Energy Technology Data Exchange (ETDEWEB)

To determine the diagnostic accuracy of iofetamine hydrochloride I 123 (IMP) with single photon emission computed tomography in Alzheimer's disease, we studied 58 patients with AD and 15 age-matched healthy control subjects. We used a qualitative method to assess regional IMP uptake in the entire brain and to rate image data sets as normal or abnormal without knowledge of subjects'clinical classification. The sensitivity and specificity of IMP with single photon emission computed tomography in AD were 88% and 87%, respectively. In 15 patients with mild cognitive deficits (Blessed Dementia Scale score, less than or equal to 10), sensitivity was 80%. With the use of a semiquantitative measure of regional cortical IMP uptake, the parietal lobes were the most functionally impaired in AD and the most strongly associated with the patients' Blessed Dementia Scale scores. These ...

1990-04-01

6

Altered myocardial substrate metabolism is associated with myocardial dysfunction in early diabetic cardiomyopathy in rats: studies using positron emission tomography  

UK PubMed Central (United Kingdom)

BackgroundIn vitro data suggest that changes in myocardial substrate metabolism may contribute to impaired myocardial function in diabetic cardiomyopathy (DCM)....Full Text Available

7

PET/CT-guided interventional procedures: rationale, justification, initial study, and research plan  

International Nuclear Information System (INIS)

Positron-emission tomography (PET) and PET/CT (computed tomography) are becoming increasingly important for diagnosis and treatment of cancer. Clinically relevant changes can sometimes be seen on PET that are not seen on other imaging modalities. However, PET is not suitable for guiding biopsy as the images are not obtained in real-time. Therefore, our research group has begun developing a concept for PET/CT-guided interventional procedures. This paper presents the rationale for this concept, outlines our research plan, and includes an initial study to evaluate the relative sensitivity of CT and PET/CT in detecting suspicious lesions. (orig.)

2007-06-01

8

PET/CT cardiology: an area whose boundaries are still out of sight  

International Nuclear Information System (INIS)

Positron emission tomography (PET) and X-ray computed tomography (CT) performed with PET/CT cameras allow us to obtain concurrently information on the presence and degree of alterations of myocardial perfusion and metabolism and on coronary arteries calcification. Furthermore, by gated myocardial perfusion studies, PET may provide crucial information on regional coronary blood flow reserve and endothelial dysfunction. A number of recent papers provide some insight on the potential of PET/CT in cardiology and in the assessment of various cardiovascular diseases including various types of vasculitis and metabolic diseases.

2006-05-01

9

PET/MRI hybrid imaging: devices and initial results  

British Library Electronic Table of Contents (United Kingdom)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest...

2008-01-01

10

Synthesis of C-11 iodoantipyrine for positron emission tomography  

Energy Technology Data Exchange (ETDEWEB)

We have developed a method for the synthesis of C-11 iodoantipyrine. Carbon-11-labeled methyl iodide, prepared from /sup 11/CO2, was used to methylate 3-methyl-1-phenyl-2-pyrazolin-5-one to form C-11 antipyrine. Following silica-gel column chromatography and iodination, radiochemical purity of the C-11 iodoantipyrine was more than 99.5%, with a 10% yield and a specific activity of 30 mCi/mumol. Preliminary animal studies showed complete cerebral extraction and local cerebral blood-flow values that were within 4.6% of those obtained using C-14 iodoantipyrine. The C-11 analog, with positron emission tomography, will facilitate local cerebral blood-flow studies in human subjects.

1981-06-01

11

Development of Methods for Obtaining Position Image and Chemical Binding Information from Flow Experiments of Porous Media  

Energy Technology Data Exchange (ETDEWEB)

Existing oil reservoirs might be more fully exploited if the properties of the flow of oil and water in porous media were better known. In laboratory experiments it is important to collect as much information as possible to make a descriptive model of the system, including position imaging and chemical binding information. This thesis develops nuclear methods for obtaining position image and chemical binding information from flow experiments of porous media. A combined positron emission tomography and single photon emission computed tomography system to obtain position images, and a time-differential perturbed angular correlation system to obtain chemical binding information, have been built and thoroughly tested. 68 refs., 123 figs., 14 tabs.

1998-12-01

12

Breast imaging with a dedicated PEM  

International Nuclear Information System (INIS)

During the last decade there was a growing interest on the application of Positron Emission Tomography, PET, techniques to Breast Imaging. More recently, preliminary results suggested the use of dedicated devices to Breast Imaging using the same technique, the so-called Positron Emission Mammography cameras, PEM. In this article we review the arguments leading to a dedicated instrument. Based on these arguments we describe the concept of a PEM camera under development within the Crystal Clear Collaboration and the first results of its expected performance in terms of sensitivity and position resolution.

2004-07-11

13

Statistical mapping analysis of serotonin synthesis images generated in healthy volunteers using positron-emission tomography and alpha-[11C]methyl-L-tryptophan.  

UK PubMed Central (United Kingdom)

OBJECTIVES: To assess the suitability of analyzing functional images of brain serotonin (5-HT) synthesis with statistical parametric mapping (SPM), and to investigate further possible sex-related regional...Full Text Available

2000-09-01

14

Single photon emission computed tomography and its neurological application  

Energy Technology Data Exchange (ETDEWEB)

A review is made of the various brain imaging agents utilised in the post few years with their own characters and respective advantages: cerebral blood volume tracers, non diffusible tracers, diffusible tracers among which gases and lipophilic agents. Our results with IAMP and SPECT are presented in two different clinical application fields: normal pressure hydrocephalus and cerebral ischemia.

1984-12-01

15

Single photon emission computed tomography and its neurological application  

International Nuclear Information System (INIS)

A review is made of the various brain imaging agents utilised in the post few years with their own characters and respective advantages: cerebral blood volume tracers, non diffusible tracers, diffusible tracers among which gases and lipophilic agents. Our results with IAMP and SPECT are presented in two different clinical application fields: normal pressure hydrocephalus and cerebral ischemia.

16

Scintigraphic imaging of dementia: Technical acquisition  

International Nuclear Information System (INIS)

Scintigraphic imaging of dementia relies today essentially on the study of brain Single Photo Emission Computed Tomography (SPECT) perfusion, after intravenous injection of 99mTc radio-pharmaceutic. This paper is based on the guidelines published in October 2001 by the European Association of Nuclear Medicine (http://eanm.org/). (author)

2007-06-01

17

Preparation and radiolabeling of IBZM: a potential D-2 specific brain imaging agents for SPECT  

International Nuclear Information System (INIS)

In developing new receptor-site specific brain imaging agents labeled with I-123 for single photon emission computed tomography (SPECT), an analog of raclopride, 3-["1"2"5I]-iodo-N-[(1-ethyl-2-pyrrolidinyl)-methyl]-2-hydroxy-6-me-thoxy benzamide (IBZM), was prepared using a method similar to that reported for raclopride and its derivatives. (author).

18

PET and MR imaging in a neuro-Behcet syndrome  

Energy Technology Data Exchange (ETDEWEB)

Positron emission tomography (PET) and magnetic resonance imaging (MRI) studies were performed on a case of neuro-Behcet's syndrome. In accordance with the clinical signs, FDG PET (using /sup 18/F-labeled 2-F-2'-desoxyglucose) revealed disseminated storage defects in the cerebrum and cerebellum. Focal regions of enhanced signal intensity were demonstrated in the parietal white matter of the cerebrum in T2-weighted images and in the brain stem by MRI. (orig.).

1989-11-01

19

Development of an experimental installation for short-lived isotopes production in INR linac  

International Nuclear Information System (INIS)

A possibility of short-lived isotopes production in inter-tank section between the first and the second drift tube tanks (20.45 MeV) in INR linac is considered. At the initial stage the main efforts are concentrated on production of fluorine-18 used for positron emission tomography. The results of beam forming calculations, target heating calculations, equipment activation calculations as well as installation configuration and design are presented.

2010-01-01

20

Atlas of nuclear medicine imaging  

Energy Technology Data Exchange (ETDEWEB)

An exhaustive compendium of normal and abnormal imaging is presented. The following systems and procedures are illustrated by over 2800 captioned illustrations: liver, spleen, and hepatobiliary imaging; perfusion and ventilation lung imaging; thyroid imaging; salivary gland imaging; bone imaging; brain imaging; radionuclide cisternography; blood flow studies; gallium imaging; nuclear cardiology; and renal imaging. Not included in the atlas are adrenal imaging procedures and emission computed tomography. (ERB)

1981-01-01

21

Retroperitoneoscopic partial adrenalectomy for small adrenal tumours (<=1 cm): the Ruijin clinical experience in 88 patients  

British Library Electronic Table of Contents (United Kingdom)

Study Type - Therapy (case series)Level of Evidence 4 OBJECTIVE To present our experience of retroperitoneoscopic partial adrenalectomy (RPA) for small adrenal tumours, as with modern imaging methods small adrenal lesions are being diagnosed more commonly, and retroperitoneoscopic adrenal surgery for small adrenal tumours (PATIENTS AND METHODS We retrospectively reviewed the records of 389 consecutive retroperitoneoscopic adrenalectomies from September 2005 to December 2008, 88 of which were small adrenal tumours and treated by RPA. Ultrasonography and computed tomography (CT) were used in all patients before RPA, and magnetic resonance imaging or positron emission tomography/CT in some patients. We used RPA for adrenal tumours and total adrenalectomy for adrenal cancer. During the surgery...

2010-01-01

22

Radiopharmaceuticals labelled with positron emitting radionuclides  

International Nuclear Information System (INIS)

A brief survey is presented of the methods of preparation and of the applications of radiopharmaceuticals labelled with short-lived positron radionuclides "1"1C, "1"8F, "1"3N and "1"5O which, thanks to their energy level schemes, short half-life and the 511 keV photon radiation energy are almost ideal tracers in modern nuclear medicine and pharmacology. In conjunction with computerized tomography, they represent one of the most sensitive diagnostic imaging methods, the so-called positron emission tomography. In addition, their incorporation in the molecule of a pharmaceutical does not change the biological and chemical properties of the original molecule unlike those of radiopharmaceuticals labelled with technetium, iodine, etc. (author). 125 refs.

1989-01-01

23

PET and MRI in cardiac imaging: from validation studies to integrated applications  

International Nuclear Information System (INIS)

Positron emission tomography (PET) is the gold standard for non-invasive assessment of myocardial viability and allows accurate detection of coronary artery disease by assessment of myocardial perfusion. Magnetic resonance imaging (MRI) provides high resolution anatomical images that allow accurate evaluation of ventricular structure and function together with detection of myocardial infarction. Potential hybrid PET/MR tomography may potentially facilitate the combination of information from these imaging modalities in cardiology. Furthermore, the combination of anatomical MRI images with the high sensitivity of PET for detecting molecular targets may extent the application of these modalities to the characterization of atherosclerotic plaques and to the evaluation of angiogenetic or stem cell therapies, for example. This article reviews studies using MRI and PET in parallel to compare their performance in cardiac ...

2009-03-01

24

PET/MRI hybrid imaging: devices and initial results  

International Nuclear Information System (INIS)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest PET/MRI developments use solid-state light detectors that can be operated even at high magnetic fields. Initial ...

2008-06-01

25

Production of radiopharmaceuticals for positron emission tomography via laboratory robotics  

International Nuclear Information System (INIS)

The production of radiopharmaceuticals used in positron emission tomography (PET) can require large amounts of activity at the start of synthesis in order to yield sufficient labeled material for clinical studies. Several investigators have developed remote and automated systems for the routine production of PET radiopharmaceuticals in order to reduce radiation exposure to personnel. Such devices, however, suffer from limited flexibility and can be relatively complicated in design. These systems are also limited to the production of a single or a few closely related compounds. Furthermore, changes in chemistry would require considerable modifications in hardware and/or software in order to bring the device back into operation. To circumvent the above limitations associated with the remote production of PET radiopharmaceuticals, the authors have investigated the use of laboratory robotics as a flexible alternative to the synthesis of several ...

1987-11-15

26

Integration of SPECT with CT to plan radiotherapy fields. n application to conformal irradiation for lung carcinoma  

International Nuclear Information System (INIS)

Single photon emission computed tomography (SPECT) of lung perfusions permits to map functioning lung parenchyma with higher sensitivity than CT. Delivering higher radiations doses it used to increase local control in lung carcinoma; this strategy is based on radiobiological and clinical studies. Lung parenchyma is a dose-limiting tissue in patients irradiated for lung cancer. Functional mapping based on SPECT and CT findings permits to design radiation beams such as to minimize irradiation of functioning lung.

1999-04-01

27

The clinical application of positron emission tomography to colorectal cancer management  

International Nuclear Information System (INIS)

Colerectal cancer (CRC) is the second commonest cancer in the Western World. Successful treatment relies significantly on accurate detection and staging of primary disease as well as the early identification of the presence and extent of recurrence. Morphological imaging techniques, particularly computed tomography (CT), are well established and widely available to carry out these tasks in addition to predicting and monitoring response to therapy. This review analyses the current inadequacies for imaging CRC and critically assesses the potential role of functional imaging with positron emission tomography (PET). It was reviewed the current literature, to use the experience from the firs 1000 PET studies carried out at the institution and the perspective of surgical colleagues. It was found little evidence for the use of 2-["1"8F]fluoro-2-deoxy-D-glucose (FDG)-PET for screening asymptomatic individuals and current modalities ...

2001-09-01

28

Risks and safety aspects related to PET/MR examinations  

International Nuclear Information System (INIS)

The introduction of positron emission tomography (PET)/magnetic resonance (MR) systems into medical practice in the foreseeable future may not only lead to a gain in clinical diagnosis compared to PET/computed tomography (CT) imaging due to the superior soft-tissue contrast of the MR technology but can also substantially reduce exposure of patients to ionizing radiation. On the other hand, there are also risks and health effects associated with the use of diagnostic MR devices that have to be considered carefully. This review article summarizes biophysical and biological aspects, which are of relevance for the assessment of health effects related to the exposure of patients to both ionizing radiation in PET and magnetic and electromagnetic fields in MR. On this basis, some considerations concerning the justification and optimization of PET/MR examinations are presented - as far as this is possible at this very early stage. ...

2009-03-01

29

Combining anatomy and function: the path to true image fusion  

Energy Technology Data Exchange (ETDEWEB)

Modern imaging technologies visualize different aspects of disease in a non-invasive way. Considerable progress has been made in the fusion of images from different imaging modalities using software approaches. One goal of fusion software is to align anatomical and functional images and allow improved spatial localization of abnormalities. The resulting correlation of the anatomical and functional images may clarify the nature of the abnormality and help diagnose or stage the underlying disease. Whereas successful image fusion software has been developed for the brain, only limited success has been achieved for image alignment in other parts of the body. The development and current status of alternative approaches are presented. Dual-modality imaging is described with devices where two modalities are combined and mounted in a single gantry. The use of existing scanner technology ensures that no compromises are made in the clinical efficacy of either the anatomical or functional imaging ...

2001-10-01

30

A look ahead: PET/MR versus PET/CT  

Energy Technology Data Exchange (ETDEWEB)

Integration of positron emission tomography (PET) and magnetic resonance (MR) has become a topic of increasing interest to the imaging community over the past two years. In this text, the authors attempt to distinguish facts from fiction concerning such integrated systems. Analysis of existing information of combined imaging on existing brain PET/MR systems and imaging experience with PET-computed tomography (CT) is reviewed. Various types of system integration of PET and MR are discussed with completely independent systems on one hand and completely integrated systems with the possibility of simultaneous data acquisition on the other hand. Furthermore, it is discussed, what simultaneous data acquisition with nuclear imaging systems combined with MR or CT really means, as technical simultaneity may not be relevant in light of the pharmacokinetics of the nuclear tracers used. The authors conclude that combining PET/MR is an ...

2009-03-15

31

Role of positron emission tomography-computed tomography in staging and early chemotherapy response evaluation in children with neuroblastoma  

International Nuclear Information System (INIS)

To evaluate the role of positron emission tomography-computed tomography (PET-CT) in staging and determining early treatment response to chemotherapy in children with neuroblastoma (NB) and its correlation with the final outcome. Patients and Methods: Seventeen patients of NB with mean age of 51.5 months (age range 2-132 months; 14 males, 3 females) underwent serial "1"8F-fluorodeoxyglucose (FDG) PET-CT imaging. All 17 patients were for staging before any treatment. Twelve of 17 patients underwent "1"3"1I meta-iodobezylguanidine (MIBG) scan and bone scan. MIBG uptake was seen in the primary lesion in 11/12 patients. MIBG uptake in bones was seen in 3/12 patients. All bone lesions were concordant on MIBG and bone scan. Early response to chemotherapy was evaluated after two cycles using PET-CT. A 30% reduction in longest diameter was taken as cut-off value for response on CT based on the response evaluation criteria in solid ...

32

The use of healthy volunteers instead of patients to inform drug dosing studies: a [11C]raclopride PET study  

British Library Electronic Table of Contents (United Kingdom)

Rationale Receptor occupancy study has been performed to evaluate pharmacokinetic profiles in new antipsychotic drug development. While these findings highlight the value of positron emission tomography (PET) for dose-finding study, what is unclear is if it is necessary to conduct these studies in patients with schizophrenia or whether studies in healthy volunteers are adequate. Objectives To determine if it is necessary to conduct dopamine receptor occupancy studies in patients with schizophrenia or whether studies in healthy volunteers are adequate for dose-finding study, we compared the concentration?occupancy relationship in terms of EC50 between patients and healthy volunteers. Methods Ten healthy volunteers and eight patients with schizophrenia participated in the study. We measured ...

2011-01-01

33

Striatal dysfunction in attention deficit and hyperkinetic disorder  

Energy Technology Data Exchange (ETDEWEB)

We have previously reported that periventricular structures are hypoperfused in attention deficit and hyperactivity disorder (ADHD). This study has expanded the number of patients, who were divided into two groups: six patients with pure ADHD, and 13 patients with ADHD in combination with other neurologic symptoms. By using xenon 133 inhalation and emission tomography, the regional cerebral blood flow distribution was determined and compared with a control group. Striatal regions were found to be hypoperfused and, by inference, hypofunctional in both groups. This hypoperfusion was statistically significant in the right striatum in ADHD, and in both striatal regions in ADHD with other neuropsychologic and neurologic symptoms. The primary sensory and sensorimotor cortical regions were highly perfused. Methylphenidate increased flow to striatal and posterior periventricular regions, and tended to decrease flow to primary sensory regions. Low ...

1989-01-01

34

Solute carrier transporters as targets for drug delivery and pharmacological intervention for chemotherapy  

British Library Electronic Table of Contents (United Kingdom)

Abstract Many solute carrier transporters that interact with anticancer agents and contribute to their pharmacokinetics have been shown to be differentially upregulated in cancer cells as a result of adaptive response to altered nutritional requirements. This review focuses on pathophysiological function of membrane transporters responsible for the influx of physiological substances including oligopeptides, amino acids, and organic cations and anions, and summarizes the recent knowledge regarding mechanisms in their gene expressions. Broad substrate specificity of enhanced oligopeptide H+/peptide cotransporter 1 activity in cancer cells is useful for tumor tissue-specific delivery of chemotherapeutic agents and positron emission tomography diagnostic probes. Amino acid transporters such as...

2011-01-01

35

Radioiodinated phenoxyacetic acid derivatives as potential brain imaging agents, 2; Structure-biodistribution relationship  

Energy Technology Data Exchange (ETDEWEB)

In developing new brain imaging agents for single photon emission computed tomography (SPECT), we synthesized eleven radioiodinated phenoxyacetic acid derivatives and investigated the relationship between the chemical structure and in vivo characteristics. Biodistribution studies in mice revealed high initial brain uptake for all the compounds. Blood radioactivity level depended markedly upon the chemical stability of the compound. The alpha,alpha-dimethylester derivative, amide derivatives and diamine derivatives, which were stable to hydrolysis, showed low blood activity levels following intravenous administration. Disappearance of the ester and amide compounds from the brain was rapid. However, the diamine derivatives displayed improved retention in the brain. Compounds 3a and 4 possessed the best combination of high brain uptake and sufficient retention to be useful as potential brain imaging radiopharmaceuticals with SPECT devices.

1989-09-01

36

Radioiodinated 1-substituted-4-phenylpiperazines as potential brain imaging agents  

Energy Technology Data Exchange (ETDEWEB)

A series of four 125I-labeled 1-substituted-4-phenylpiperazines were prepared and evaluated in rats as potential brain imaging agents. The compounds were labeled using (125I)iodide/chloramine-T or iodine monochloride and isolated in 48-60% radiochemical yields. The tissue distribution studies indicated that a butyrophenone derivative demonstrated the best overall brain-imaging properties. Compared with the compounds having other 1-substituents this agent had a more prolonged retention of activity in the brain and higher brain-to-blood ratios over the 4-h period studied. The in vivo behavior of this agent is comparable to that of radioiodinated N-isopropyl-p-iodoamphetamine, and, because it can be labeled directly via electrophilic methods, it has substantial potential for use in brain imaging with single photon emission computed tomography.

1985-01-01

37

Imaging pharmacodynamics in oncology. The potential significance of 'flares'  

International Nuclear Information System (INIS)

The clinical use of "1"8F-fluorodeoxyglucose (FDG) positron emission tomography in monitoring anticancer treatment is expanding. At the same time a number of radiotracers aiming to image different aspects of tumour biology such as proliferation and apoptosis are being developed. However, the factors determining changes of radiotracer uptake parameters in response to treatment are not well understood. In many cases, cellularity may be the primary determinant of changes of FDG uptake and may confound the interpretation of metabolic changes. Early imaging assessments have in some cases showed transient increases of uptake parameters, commonly termed 'flares', which are likely to be unaffected by cellularity and directly reflect pharmacodynamics at a cellular level. In this review a number of settings where molecular imaging 'flares' have been described are discussed. Such changes may often be clinically informative and warrant careful study as ...

2010-04-01

38

Fast Beam Intensity Measurements for the LHC  

CERN Document Server

Particle accelerators are constructed and operated for a wide variety of applications. In particle physics - the branch of physics that studies the elementary constituents of matter and forces between them - high energy accelerators are used to look deep into the structure of matter. Medical particle accelerators are used for example in medicine to treat tumours [31], in imaging techniques such as Positron Emission Tomography (PET) [24], or for the radio-isotopes production. They also serve in many other industrial branches, e.g. geology, radiocarbon dating [39], molecular complex spectroscopy, lithography, food preservation etc. The eld of accelerator technology draws knowledge and expertise from a wide range of scientic disciplines and uses the latest technical knowledge. The incomplete list of covered disciplines includes mathematics, physics, electronics, computing, electromagnetic eld technology, microwave technology, cryogenics, vacuum ...

2010-01-01

39

Copper-64 Radiopharmaceuticals for PET Imaging of Cancer: Advances in Preclinical and Clinical Research  

British Library Electronic Table of Contents (United Kingdom)

Summation Copper-64 (T1/2?=?12.7 hours; ?+, 0.653?MeV [17.8 %]; ??, 0.579?MeV [38.4 %]) has decay characteristics that allow for positron emission tomography (PET) imaging and targeted radiotherapy of cancer. The well-established coordination chemistry of copper allows for its reaction with a wide variety of chelator systems that can potentially be linked to peptides and other biologically relevant small molecules, antibodies, proteins, and nanoparticles. The 12.7-hours half-life of 64Cu provides the flexibility to image both smaller molecules and larger, slower clearing proteins and nanoparticles. In a practical sense, the radionuclide or the 64Cu-radiopharmaceuticals can be easily shipped for PET imaging studies at sites remote to the production facility. Due to the versatility of 64Cu, ...

2009-01-01

40

Proceedings of clinical SPECT [single photon emission computed tomography] symposium  

International Nuclear Information System (INIS)

It has been five years since the last in-depth American College of Nuclear Physicians/Society of Nuclear Medicine Symposium on the subject of single photon emission computed tomography (SPECT) was held. Because this subject was nominated as the single most desired topic we have selected SPECT imaging as the basis for this year's program. The objectives of this symposium are to survey the progress of SPECT clinical applications that have taken place over the last five years and to provide practical and timely guidelines to users of SPECT so that this exciting imaging modality can be fully integrated into the evaluation of pathologic processes. The first half was devoted to a consideration of technical factors important in SPECT acquisition and the second half was devoted to those organ systems about which sufficient clinical SPECT imaging data are available. With respect to the technical aspect of the program we have selected the key areas which ...

1986-09-22

41

Multidimensional B-spline parameterization of the detection probability of PET systems to improve the efficiency of Monte Carlo simulations  

International Nuclear Information System (INIS)

Accurate modeling of system response and scatter distribution is crucial for image reconstruction in emission tomography. Monte Carlo simulations are very well suited to calculate these quantities. However, Monte Carlo simulations are also slow and many simulated counts are needed to provide a sufficiently exact estimate of the detection probabilities. In order to overcome these problems, we propose to split the simulation into two parts, the detection system and the object to be imaged (the patient). A so-called 'virtual boundary' that separates these two parts is introduced. Within the patient, particles are simulated conventionally. Whenever a photon reaches the virtual boundary, its detection probability is calculated analytically by evaluating a multi-dimensional B-spline that depends on the photon position, direction and energy. The unknown B-spline knot values that define this B-spline are fixed by a prior 'pre-' simulation that needs to ...

2010-06-21

42

Kinetics of in vivo binding of antagonist to muscarinic cholinergic receptor in the human heart studied by Positron Emission Tomography  

Energy Technology Data Exchange (ETDEWEB)

Positron Emission Tomography (PET) was used to analyze in vivo antagonist binding to human myocardial muscarinic cholinergic receptor. The methiodide salt of the muscarinic antagonist, quinuclidinyl benzilate (MQNB), was labeled with the positron emitter, Carbon-11, and injected intravenously to 8 normal subjects. /sup 11/C-MQNB concentration was determined in vivo in the ventricular septum from 40 cross-sectional images acquired at the same transverse level over a period of 70 minutes. In 4 subjects, various amounts of unlabeled atropine were rapidly injected at 20 minutes to study whether atropine competitively inhibited MQNB. The kinetics of binding of /sup 11/C-MQNB were not the same in vivo and in vitro. The apparent dissociation rate of /sup 11/C-MQNB in vivo was much slower (by 1 to 2 orders of magnitude) than that observed in vitro with /sup 3/H-QNB. After atropine injection, /sup 11/C-MQNB dissociated from its binding sites at a rate ...

1984-08-27

43

[Somatic radiation risk in conventional tomography of the skull and thorax].  

Science.gov (United States)

The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other x-ray examinations, especially computerised tomography. PMID:7134769

1982-10-01

44

Somatic radiation risk in conventional tomography of the skull and thorax  

Energy Technology Data Exchange (ETDEWEB)

The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other X-ray examinations, especially computerised tomography.

1982-10-01

45

Somatic radiation risk in conventional tomography of the skull and thorax  

International Nuclear Information System (INIS)

The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other X-ray examinations, especially computerised tomography. (orig.).

1982-01-01

46

Optical Coherence Tomography Findings in Idiopathic Macular Holes  

UK PubMed Central (United Kingdom)

Purpose. To describe the characteristics of idiopathic macular holes (MH) on optical coherence tomography (OCT) and correlate OCT with clinical assessment. Design....Full Text Available

2011-01-01

47

Computed tomography of head in Clinic Pediatrics  

Energy Technology Data Exchange (ETDEWEB)

138 unselected head tomographies of children by computer are reported and analysed. The major aspect stressed by the authors is the excellent precision of this radiological technique.

1982-02-01

48

Usefulness of "1"8F-FDG PET in intrahepatic cholangiocarcinoma  

International Nuclear Information System (INIS)

Surgical resection is the only curative treatment strategy for intrahepatic cholangiocarcinoma (CC). Therefore, accurate staging is essential for appropriate management of patients with CC. We assessed the usefulness of 2-["1"8F]fluoro-2-deoxy-d-glucose (FDG) positron emission tomography (PET) in the staging of CC. We undertook a retrospective review of FDG PET images in 21 patients (10 female, 11 male; mean age 57 years) diagnosed with CC. Ten patients had hilar CC and 11, peripheral CC. Patients underwent abdominal magnetic resonance imaging (MRI) (n=20) and computed tomography (CT) (n=12) for the evaluation of primary tumours, and chest radiography and whole-body bone scintigraphy for work-up of distant metastases. For semi-quantitative analysis, the maximum voxel standardised uptake value (SUV_m_a_x) was obtained from the primary tumour. All peripheral CCs showed intensely increased FDG uptake, and some demonstrated ...

2003-11-01

49

Trial of using computer tomography in the diagnosis of mediastinal diseases in children  

Energy Technology Data Exchange (ETDEWEB)

In 15 children (in age 2 weeks - 15 years) the computer tomography beside radiological examination was done because of mediastinal diseases. In all cases the computer tomography was valuable. In 4 cases obtained results have changed diagnostic conclusions. The examples are described showing the usefulness of the computer tomography as supplementary diagnostic method in mediastinal diseases in children.

1981-01-01

53

Importance of computer tomography in paediatric diagnostics of abdominal and pelvic tumours  

Energy Technology Data Exchange (ETDEWEB)

In a joint study conducted by the University Clinic of Radiology, Graz, and the Medical University Clinic, Innsbruck, the results of computer tomography examinations of the abdomen and pelvis in 23 cases of tumours in children are discussed. In children computer tomography resents special difficulties on account of the very poorly developed fatty layers between the organs and the increased incidence of movement artifacts. The importance of computer tomography for the diagnosis of abdominal and pelvic tumours is discussed.

1980-03-01

54

Demonstration of neutron radiography and computed tomography at the University of Texas thermal neutron imaging facility  

Energy Technology Data Exchange (ETDEWEB)

A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed and built at the University of Texas TRIGA reactor. Herein the authors present preliminary results of radiography and tomography test experiments. These preliminary results showed that the beam is of high quality and is suitable for radiography and tomography applications. A more detailed description of the facility is given elsewhere.

1999-09-01

55

Demonstration of neutron radiography and computed tomography at the University of Texas thermal neutron imaging facility  

International Nuclear Information System (INIS)

A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed and built at the University of Texas TRIGA reactor. Herein the authors present preliminary results of radiography and tomography test experiments. These preliminary results showed that the beam is of high quality and is suitable for radiography and tomography applications. A more detailed description of the facility is given elsewhere

1999-06-06

56

The chemistry of technetium(V) complexes containing tetradentate amine oxime ligands  

International Nuclear Information System (INIS)

Technetium-99m was previously shown to form a stable, neutral and lipopholic complex with propylene amine oxime, PnAO. This Tc-99m-PnAO complex was shown to efficiently extracted by normal brain. However, it is not sufficiently retained in the brain to image its cerebral distribution using convertional SPECT (single-photon emission computerized tomography) instrumentation. A number of derivatives of PnAO have been synthesized and their technetium-99m complexes have been biologically evaluated. A number of these have been shown to have high brain uptake without exhibiting the rapid cerebral clearance that was observed with Tc-99m-PnAO. To better understand the chemistry of these potential brain imaging agents, a number of technetium-99 complexes of derivatives of PnAO have been synthesized and characterized. Substituents on the tetradentate amine oxime backbone were varied to probe the effect(s) of these structural changes on the properties of ...

57

Reversal of brain metabolic abnormalities following treatment of AIDS dementia complex with 3'-azido-2',3'-dideoxythymidine (AZT, zidovudine): a PET-FDG study  

International Nuclear Information System (INIS)

Brain glucose metabolism was evaluated in four patients with acquired immunodeficiency syndrome (AIDS) dementia complex using ["1"8F]fluorodeoxyglucose (FDG) and positron emission tomography (PET) scans at the beginning of therapy with 3'-azido-2',3'-dideoxythymidine (AZT, zidovudine), and later in the course of therapy. In two patients, baseline, large focal cortical abnormalities of glucose utilization were reversed during the course of therapy. In the other two patients, the initial PET study did not reveal pronounced focal alterations, while the post-treatment scans showed markedly increased cortical glucose metabolism. The improved cortical glucose utilization was accompanied in all patients by immunologic and neurologic improvement. PET-FDG studies can detect cortical metabolic abnormalities associated with AIDS dementia complex, and may be used to monitor the metabolic improvement in response to AZT treatment.

58

Radiopharmaceuticals for the imaging of functional abnormalities of the developing brain  

International Nuclear Information System (INIS)

The measurement of physiological parameters in man is possible with the help of positron emission tomography (PET) and radiopharmaceuticals labeled with short lived positron emitters as C 11, N 13, O 15 and F 18. With the use of this substances it is possible to make a tomographic map defining regional metabolic parameters in normal and diseased brain. This technique has therefore also be named 'in vivo autoradiography'. The possibility of applying C 11 or F 18 labeled deoxyglucose with PET for detecting regional and local changes in cerebral metabolic rate of glucose in brain development in children of 5 days to 1 year of age is discussed. Beyond this a relationship between cerebral metabolic rate of glucose, cerebral blood flow and cerebral metabolic rate of oxygen by use of this technique after inhalation of O 15 and C 11-labeled CO_2 is shown. Attention is drawn to the application of C 11-methyl-spiperone and PET to visualize dopamine ...

59

Radioiodinated phenoxyacetic acid derivatives as potential brain imaging agents, 2  

International Nuclear Information System (INIS)

In developing new brain imaging agents for single photon emission computed tomography (SPECT), we synthesized eleven radioiodinated phenoxyacetic acid derivatives and investigated the relationship between the chemical structure and in vivo characteristics. Biodistribution studies in mice revealed high initial brain uptake for all the compounds. Blood radioactivity level depended markedly upon the chemical stability of the compound. The #alpha#,#alpha#-dimethylester derivative (1e), amide derivatives (2a-c) and diamine derivatives (3a, b, 4), which were stable to hydrolysis, showed low blood activity levels following i.v. administration. Disappearance of the ester and amide compounds from the brain was rapid. However, the diamine derivatives displayed improved retention in the brain. Compounds 3a and 4 possessed the best combination of high brain uptake and sufficient retention to be useful as potential brain imaging radiopharmaceuticals with ...

60

Radiohalogen-labeled imaging agents. 3. Compounds for measurement of brain blood flow by emission tomography  

Energy Technology Data Exchange (ETDEWEB)

The radioiodine-labeled amines currently available as brain-imaging agents, based on our previous work and that of others, are prepared either by exchange labeling or by direct iodination of a protected intermediate. The intrinsic slowness of these processes limits their potential for use with the positron-emitting 122I, as it has a half-life of only 3.6 min. This isotope has advantages of a low dose to the patient and availability from a generator containing the parent 20-h 122Xe. To develop a radiopharmaceutical in which 122I could be utilized, we prepared a number of secondary and tertiary amines (maintaining the 2,5-dimethoxy substitution pattern which allows direct iodination at the 4-position) with 131I. The organ distributions of these compounds were studied, and the best properties were found in the N,N-dimethyl homologue (2,5-dimethoxy-N,N-dimethyl-4-iodoamphetamine). This compound was successfully synthesized in a matter of seconds, with a chemical yield and radioactive ...

1984-08-01

61

Radiohalogen-labeled imaging agents. 3. Compounds for measurement of brain blood flow by emission tomography  

International Nuclear Information System (INIS)

The radioiodine-labeled amines currently available as brain-imaging agents, based on our previous work and that of others, are prepared either by exchange labeling or by direct iodination of a protected intermediate. The intrinsic slowness of these processes limits their potential for use with the positron-emitting 122I, as it has a half-life of only 3.6 min. This isotope has advantages of a low dose to the patient and availability from a generator containing the parent 20-h 122Xe. To develop a radiopharmaceutical in which 122I could be utilized, we prepared a number of secondary and tertiary amines (maintaining the 2,5-dimethoxy substitution pattern which allows direct iodination at the 4-position) with 131I. The organ distributions of these compounds were studied, and the best properties were found in the N,N-dimethyl homologue (2,5-dimethoxy-N,N-dimethyl-4-iodoamphetamine). This compound was successfully synthesized in a matter of seconds, with a chemical yield and radioactive ...

62

Positron emission tomography for modelling of geochemical transport processes in clay  

Energy Technology Data Exchange (ETDEWEB)

Geological clay formations are investigated for use as final underground deposit for heat producing nuclear waste. Special kinds of clay (e.g. bentonite) can also be used for the construction of geotechnical barriers. For the long time safety prognosis of the nuclear waste repositories the development of geochemical transport models is indispensable. The transport of aqueous solutions in clay is a complex process. The three-layer-minerals bentonite and illite swell by the adsorption of water, if the volume is restricted a high swelling pressure develops. The excellent barrier effect of natural clay formations and geotechnical clay barriers is based on the high swelling pressure and the high adsorption capacity for radionuclides and other pollutants. The two-layer-mineral kaolinite has no swelling capacity. In contrast to sandy layers a special geochemical transport potential exists in clay besides the well known matrix potential which influences essentially the transport process. ...

2004-07-01

63

Pet's research at the SHFJ, Cea, one example: development and validation of a radioligand for the study of the cerebral dopaminergic system; La recherche en TEP au SHFJ, CEA. Un exemple: developpement et validation de radioligands pour l'etude du systeme dopaminergique  

Energy Technology Data Exchange (ETDEWEB)

The aim of this work is the evaluation of biodistribution and radiation dosimetry of a cocaine analog, the N-(3-iodo-prop-2E-enyl)-2beta-carbo-methoxy-3beta-(4-methyl-phenyl) nor-tropane (PE2I), labeled with carbon 11 ([{sup 11}C]PE2I). The [{sup 11}C]PE2I is a selective radioligand for imaging neuronal dopamine transporter (DAT) with positron emission tomography (PET). The DAT is a membrane-bound pre synaptically located protein that regulates the concentration of dopamine at nerve terminals. DAT radioligands are often used to evaluate the progression of Parkinson's disease or the efficiency of neuro-protective therapeutics and, typically, these studies required several successive PET scans. (author)

2005-10-15

64

Nitroimidazole conjugates of bis(thiosemicarbazonato)64Cu(II) - Potential combination agents for the PET imaging of hypoxia  

British Library Electronic Table of Contents (United Kingdom)

Combination agents comprising two different pharmacophores with the same biological target have the potential to show additive or synergistic activity. Bis(thiosemicarbazonato)copper(II) complexes (e.g. 64Cu-ATSM) and nitroimidazoles (e.g. 18F-MISO) are classes of tracer used for the delineation of tumor hypoxia by positron emission tomography (PET). Three nitroimidazole-bis(thiosemicarbazonato)copper(II) conjugates were produced in order to investigate their potential as combination hypoxia imaging agents. Two were derived from the known bifunctional bis(thiosemicarbazone) H2ATSM/A and the third from the new precursor diacetyl-2-(4-N-methyl-3-thiosemicarbazone)-3-(4-N-ethylamino-3-thiosem icarbazone) - H2ATSM/en. Oxygen-dependent uptake studies were performed using the 64Cu radiolabelled ...

2010-01-01

65

Evaluation of selective alveolo-bronchography with Fuji computed radiography and x-ray CT  

International Nuclear Information System (INIS)

Selective alveolo-bronchography (SAB) has been routinely used to evaluate anatomical changes in the bronchiole and its distal air spaces. A narrowing of the bronchiole and abnormal pooling of contrast medium in the destroyed air space are the prime findings. Since the object of radiography is extremely thin, direct magnification radiography is mandatory to obtain radiologic details. However, the problem with this technique is that radiographic quality varies depending upon the size of the patient and the concentration of contrast medium to be introduced in the lung. This study had two goals. One was to improve the image quality of SAB by Fuji Computed Radiography (FCR). FCR provides radiographs with a good contrast and stable density throughout a wide range of exposure factors which occur in the use of SAB. The other goal was to separately evaluate morphological abnormalities in the outer and inner zones of the lung using X-ray CT. This idea was derived from our observations in ...

1986-01-01

66

Evaluation of craniosynostosis surgery. Technetium-99m-HMPAO SPECT cerebral blood flow study in children with craniosynostosis  

International Nuclear Information System (INIS)

Premature fusion of multiple cranial sutures has been associated with increased intracranial pressure and the potential for mental impairment. Isolated craniosynostosis, however, is considered a benign condition primarily reconstructed for aesthetic purposes. A comparative analysis, to assess the differences between pre- and post operatory cerebral perfusion of patients who underwent surgery for simple cranisynostosis, was performed using single positron emission computed tomography ''SPECT'' Images. Cerebral blood flow studies were performed using "9"9"mTc-HMPAO SPECT in children with simple cranisynotoses. The subjects were 8 children with craniosynostosis (age, 2 months-9 years). Preoperative revealed regional hypovascularity in the cerebral hemisphere in 5 cases (62%). In 6 patients the cerebral blood flow normalized or increased after craniofacial reconstruction. We demonstrated the presence of regional hypovascularity in the cerebral ...

1998-09-01

67

BDTPS The BNCT Treatment Planning System jointly developed at DIMNP and JRC/IE  

CERN Document Server

The idea to couple the Treatment Planning System (TPS) to the information on the real boron distribution in the patient is the main added value of the new methodology set-up at DIMNP of University of Pisa, in collaboration with the JRC of Petten (NL). The methodology has been implemented in the new TPS, called BDTPS (Boron Distribution Treatment Planning System), which takes into account the actual boron distribution in the patient brain, while the standard TPS assumes a uniform boron distribution, absolutely far from the reality. Nowadays, Positron Emission Tomography (PET) is able to provide this in vivo information. The new TPS, based on the Monte Carlo technique, has been validated comparing the main BNCT parameters (thermal flux, boron dose, etc.) as measured during the irradiation of a special heterogeneous boron phantom (HEBOM), ad hoc designed, as calculated by the BDTPS and by the standard TPS SERA. An evident SERA overestimation of ...

2003-01-01

68

Automated production of ["1"1C]acetate and ["1"1C]palmitate using a modified GE Tracerlab FX_C_-_P_r_o  

International Nuclear Information System (INIS)

As researchers explore new applications for positron emission tomography radiopharmaceuticals, the demand for effective and readily available radiopharmaceuticals continues to increase. The syntheses of two such radiopharmaceuticals, ["1"1C]acetate and ["1"1C]palmitate, can be automated on the GE Tracerlab FX_C_-_P_r_o by utilizing Grignard reactions. Radiochemical purities of the ["1"1C]acetate and the ["1"1C]palmitate products were high (>98% and >99.9%, respectively) with average non-corrected yields of 18% (n=3) and 10% (n=5), respectively. These data comprise the validation trials for site qualification of clinical production of both radiopharmaceuticals. -- Graphical abstract: Automated syntheses of ["1"1C]acetate and ["1"1C]palmitate using a modified GE Tracerlab FX_C_-_P_r_o are reported. Radiochemical purities of the ["1"1C]acetate and the ["1"1C]palmitate products were high (>98% and >99.9%, respectively) with average ...

2011-04-01

69

Assessment of PET and MRI Polar Map using Gaussian Mixture Model  

International Nuclear Information System (INIS)

Cardiac disease research relies increasingly on small animal models and non-invasive imaging methods such as positron emission tomography (PET) and magnetic resonance imaging (MRI). Delayed enhancement magnetic resonance imaging (DE-MRI) using gadolinium-based contrast agents appear to be a visualizing infracted myocardium with high spatial resolution. Polar map (or bull's-eye image) was used to determination of the myocardial infarction area. Polar map is a comprehensive interpretation of the left ventricle. The infarct size was computed as the fraction of the total polar map areas. The threshold was computed as the percentage of mean intensity of the normal region. In other study, 50% predefined threshold value in varying range (30?70%) was most commonly use. However, predefined threshold value isn't acceptance in all case. The purpose of this study was to investigate methodological approach for automatic measurement of rat myocardial infarct ...

2010-10-01

70

Application of a beta microprobe for quantification of regional cerebral blood flow with {sup 15}O-water and PET in rhesus monkeys  

Energy Technology Data Exchange (ETDEWEB)

A beta microprobe was successfully applied to monitor arterial input function for quantification of regional cerebral blood flow (rCBF) in the monkey brain with {sup 15}O-water and positron emission tomography (PET). The sensitivity of the probe was approximately 0.83 to 1.67 cps/kBq/ml depending on the studies. A preliminary study was performed to find a suitable use and to evaluate the performance of the system and data analysis procedure. The results showed that dispersion correction of measured input function was unnecessary if microprobes were connected directly to the arterial catheter. Then multiple CBF measurements were done in three monkeys under anesthesia. Identical regions of interest were placed with the aid of magnetic resonance imaging (MRI) of each monkey and rCBF values were estimated. Estimated rCBFs were reproducible for several measurements. The mean CBF value for a pentobarbital anesthetized monkey was 46.0 ml/min/100 g ...

1998-02-01

71

Analysis of the quantitative structure activity relationship of technetium-99m-labeled diaminedithiol (DADT) and propyleneamineoxime (PAO) brain blood flow analogues  

Energy Technology Data Exchange (ETDEWEB)

In the search for new brain imaging agents for use with single photon emission computed tomography (SPECT), quantitative structure activity relationship (QSAR) analysis of the correlations between initial brain uptake and physicochemical parameters like lipophilicity, log P, molecular weight, log MW and log U/D (undissociated/dissociated), of the {sup 99m}Tc-DADT (diaminedithiol) complexes and {sup 99m}Tc-PAO (propyleneaminoxime) complexes have been analyzed. High correlations are found for both the {sup 99m}Tc-DADT complexes (r = 0.94) and for the {sup 99m}Tc-PAO complexes (r = 0.83) which are significant at 99.9 and 99.5 percentile level, respectively. These results will help the further design of better ligands for {sup 99m}Tc in brain imaging. (author).

1991-01-01

72

Evaluation of the hemodynamics of the femoral head compared with the ilium, femoral neck and femoral intertrochanteric region in healthy adults. Measurement with positron emission tomography (PET)  

International Nuclear Information System (INIS)

Non-traumatic osteonecrosis of the femoral head (ONF) is considered to be a disease that occurs primarily due to ischemia of the femoral head, while its etiology and pathology are not fully understood. It is therefore necessary to identify the characteristics of the hemodynamics of the femoral head. In this study, the hemodynamics in the ilium and proximal regions of the femur, including the femoral head, was investigated using positron emission tomography (PET). The subjects of this study consisted of 8 hip joints of four healthy male adults and 3 hip joints on the contralateral side of a femoral neck fracture, avulsion fracture of the greater trochanter and coxarthrosis (1 case each, all females) for a total of 11 hip joints of 7 subjects. The ages of the subjects ranged from 25 to 87 years (average age: 54 years). Blood flow was measured by means of the H_2"1"5O dynamic study method and blood volume was measured by means of the "1"5O-labeled ...

2005-10-01

73

Characterization of [[sup 123]I]IDAM as a novel single-photon emission tomography tracer for serotonin transporters  

Energy Technology Data Exchange (ETDEWEB)

Development of selective serotonin transporter (SERT) tracers for single-photon emission tomography (SPET) is important for studying the underlying pharmacology and interaction of specific serotonin reuptake site inhibitors, commonly used antidepressants, at the SERT sites in the human brain. In search of a new tracer for imaging SERT, IDAM (5-iodo-2-[[2-2-[(dimethylamino)methyl]phenyl]thio]benzyl alcohol) was developed. In vitro characterization of IDAM was carried out with binding studies in cell lines and rat tissue homogenates. In vivo binding of [[sup 125]I]IDAM was evaluated in rats by comparing the uptakes in different brain regions through tissue dissections and ex vivo autoradiography. In vitro binding study showed that IDAM displayed an excellent affinity to SERT sites (K[sub i]=0.097 nM, using membrane preparations of LLC-PK[sub 1] cells expressing the specific transporter) and showed more than 1000-fold of selectivity for SERT over ...

1999-08-01

74

Synthesis, characterization, and evaluation of a novel bifunctional chelating agent for the lead isotopes {sup 203}Pb and {sup 212}Pb  

Energy Technology Data Exchange (ETDEWEB)

Radioisotopes of Pb(II) have been of some interest in radioimmunotherapy and radioimmunoimaging (RII). However, the absence of a kinetically stable bifunctional chelating agent for Pb(II) has hampered its use for these applications. {sup 203}Pb (T{sub 1/2}=52.02 h) has application potential in RII, with a {gamma}-emission that is ideal for single photon emission computerized tomography, whereas {sup 212}Pb (T{sub 1/2}=10 h) is a source of highly cytotoxic {alpha}-particles via its decay to its {sup 212}Bi (T{sub 1/2}=60 min) daughter. The synthesis of the novel bifunctional chelating agent 2-(4-isothiocyanotobenzyl)-1,4,7,10-tetraaza-1,4,7,10-tetra-(2-carbamoyl methyl)-cyclododecane (4-NCS-Bz-TCMC) is reported herein. The Pb[TCMC]{sup 2+} complex was less labile to metal ion release than Pb[DOTA]{sup 2-} at pH 3.5 and below in isotopic exchange experiments. In addition to increased stability to Pb{sup 2+} ion release at low ...

2000-01-01

75

Synthesis, characterization, and evaluation of a novel bifunctional chelating agent for the lead isotopes "2"0"3Pb and "2"1"2Pb  

International Nuclear Information System (INIS)

Radioisotopes of Pb(II) have been of some interest in radioimmunotherapy and radioimmunoimaging (RII). However, the absence of a kinetically stable bifunctional chelating agent for Pb(II) has hampered its use for these applications. "2"0"3Pb (T_1_/_2=52.02 h) has application potential in RII, with a #gamma#-emission that is ideal for single photon emission computerized tomography, whereas "2"1"2Pb (T_1_/_2=10 h) is a source of highly cytotoxic #alpha#-particles via its decay to its "2"1"2Bi (T_1_/_2=60 min) daughter. The synthesis of the novel bifunctional chelating agent 2-(4-isothiocyanotobenzyl)-1,4,7,10-tetraaza-1,4,7,10-tetra-(2-carbamoyl methyl)-cyclododecane (4-NCS-Bz-TCMC) is reported herein. The Pb[TCMC]"2"+ complex was less labile to metal ion release than Pb[DOTA]"2"- at pH 3.5 and below in isotopic exchange experiments. In addition to increased stability to Pb"2"+ ion release at low pH, the bifunctional TCMC ...

2000-01-01

76

Status of lead and bismuth for radioimmunoimaging and radioimmunotherapy  

International Nuclear Information System (INIS)

Tumor-targeted monoclonal antibodies (mAb) might be useful as diagnostic or therapeutic agents when linked to cytotoxic or imaging reagents. Our group is working to test this hypothesis by linking cytocidal and image-producing isotopes to mAb and testing the utility of the radioimmunoconjugates formed in animal model systems. Radioiodines were first employed for these purposes,but unfavorable nuclear properties (half-lives, #gamma#-ray and #beta#-particle energies) and chemical reactivity (deiodination in vivo) limit their utility. Labeling immunoproteins with metallic radionuclides offers more versatility in that the selection of potentially useful radiometals spans the periodic table.Of the metallic radionuclides with physical properties most suited for use with mAb in nuclear medicine, few are more available or desirable than those of bismuth ("2"1"2Bi) and lead ("2"0"3Pb, "2"1"2Pb), as listed in Table 1. "2"1"2Bi or "2"1"2Pb could serve as sources for highly cytocidal ...

1990-08-26

77

Using Multidetector Computed Tomography in a Swine Model to Assess the Effects of Sublingual Nitroglycerin and Intravenous Adenosine on Epicardial Coronary Arteries  

UK PubMed Central (United Kingdom)

This study examines the effects of intravenous infusion of adenosine and sublingual nitroglycerin on coronary angiograms obtained by current-generation multidetector computed tomography. We assessed...Full Text Available

2009-12-01

78

Prevalence of Renal Artery and Kidney Abnormalities by Computed Tomography among Healthy Adults  

UK PubMed Central (United Kingdom)

Background and objectives: Management of incidental renal artery and kidney abnormalities in patients undergoing computed tomography scans is a clinical challenge because their frequency in healthy...Full Text Available

2010-03-01

79

Macular and retinal nerve fiber layer thickness in Japanese measured by Stratus optical coherence tomography  

UK PubMed Central (United Kingdom)

The purpose of this study was to determine the thickness of the macula and the retinal nerve fiber layer (RNFL) in Japanese subjects by Stratus optical coherence tomography (OCT), and to compare the...Full Text Available

2007-06-01

80

Is Computerized Tomography Angiographic Surveillance Valuable for Prevention of Tracheoinnominate Artery Fistula, a Life-Threatening Complication after Tracheostomy?  

UK PubMed Central (United Kingdom)

ObjectiveThe aim of this study was to evaluate the utility of volume-rendered helical computerized tomography (CT) angiography focusing tracheostomy tube and innominate artery for...Full Text Available

2011-02-01

81

High-Speed Ultrahigh-Resolution Optical Coherence Tomography Findings in Chronic Solar Retinopathy  

UK PubMed Central (United Kingdom)

PurposeTo describe ocular findings for a 34-year-old man with chronic solar retinopathy using high-speed ultrahigh-resolution (UHR) optical coherence tomography (OCT).Full Text Available

2008-01-01

82

Clinical Assessment of Mirror Artifacts in Spectral-Domain Optical Coherence Tomography  

UK PubMed Central (United Kingdom)

Purpose.To investigate the characteristics of a spectral-domain optical coherence tomography (SD-OCT) image phenomenon known as the mirror artifact, calculate its prevalence, analyze...Full Text Available

2010-07-01

83

Automated 3-D method for the correction of axial artifacts in spectral-domain optical coherence tomography images  

UK PubMed Central (United Kingdom)

The 3-D spectral-domain optical coherence tomography (SD-OCT) images of the retina often do not reflect the true shape of the retina and are distorted differently along the x and y...Full Text Available

84

Artery phantoms for intravascular optical coherence tomography: healthy arteries  

UK PubMed Central (United Kingdom)

We present a method to make phantoms of coronary arteries for intravascular optical coherence tomography (IV-OCT). The phantoms provide a calibrated OCT response similar to the layered structure of...Full Text Available

85

Using Acoustic Tomography to Monitor Deep Ocean Currents ...  

Science.gov (United States)

... 2009. Copyright belongs to the Marine Technology Society., The original document contains color images. 14. ABSTRACT ...

2010-06-01

88

Radiation dose in computerized tomography  

International Nuclear Information System (INIS)

Dosimetric studies in 80 patients examined with the tomographic device 'Somatom' are reported. The gonad doses are compared to those of conventional radiographic techniques.

90

Magnetic resonance imaging in childhood epilepsy  

International Nuclear Information System (INIS)

The suitability of MR imaging versus computerized tomography in observation of brain development disorders in children are compared. 13 refs.

92

Computerized tomography of the adrenal glands in the Cushing Syndrome propaedeutic  

International Nuclear Information System (INIS)

Portuguese (Mar 1983). Brazil Furlanetto, RP Abucham Filho, J. Albertotti,

1982-10-24

93

The different structural scales of the breast and their impact on time-of-flight and diffraction tomography  

Energy Technology Data Exchange (ETDEWEB)

Ultrasound tomography is an attractive imaging method for the detection of breast cancer. The complex anatomy of the breast with its different spatial scales and material property contrasts make accurate reconstructions very challenging. This paper proposes a hybrid approach whereby Travel-of-Flight and Diffraction Tomography are combined together to achieve high-resolution and high-accuracy sound-speed reconstructions. The method is validated with several numerical phantoms.

2010-01-01

94

Computer tomography used in tumour diagnosis in children  

Energy Technology Data Exchange (ETDEWEB)

Computer tomography used in the diagnosis of tumours is described in the light of particularly great diagnostic difficulties in children. Computer tomography was applied in 12 cases. A high diagnostic value of this method was demonstrated, which makes possible a more accurate diagnosis of the position of the tumour, its size, and expanding tendency. The possibility of estimating healthy tissues and organs, and those with pathological changes on the basis of differences in their density with a detection threshold at 0.5% density difference facilitates not infrequently preoperative diagnosis raising the value of the method.

1981-01-01

95

Computer tomographic ventriculography  

Energy Technology Data Exchange (ETDEWEB)

A method for elucidating complex abnormalities of CSF circulation by using a positive contrast medium (metrizamide) and computer tomography is described. The technique for the method, the results and their clinical significance is demonstrated. The value of this method is compared with traditional ventriculography and with computer tomography without the use of contrast medium. It is shown that the technique represents an important extension of the scope of computer tomography.

1982-04-01

96

Role of nuclear medicine and magnetic resonance imaging in cardiac diagnostics; Rolle der nuklearmedizinischen Verfahren und der Magnetresonanztomographie in der kardialen Diagnostik  

Energy Technology Data Exchange (ETDEWEB)

Nuclear medicine and magnetic resonance imaging (MRI) are widely used in cardiac diagnostics. Both techniques have been carefully evaluated and are equivalent for the assessment of regional and global wall motion as well as the evaluation of ejection fraction and cardiac volumes, though MRI is herein currently seen as gold standard. For evaluation of myocardial perfusion, extensive data exist for nuclear imaging, that, next to high diagnostic accuracy for evaluation of coronary artery disease, show incremental prognostic information and allow for independent risk stratification. Because of rapid technical advance, myocardial perfusion imaging has also become feasible with cardiac MRI. Results of recent studies are promising, but the data are few compared to perfusion scintigraphy. For viability assessment in patients with ischemic cardiomyopathy, positron emission tomography (PET) with FDG is currently seen as gold standard. However, single ...

2003-12-01

97

A Network Coding Approach to Loss Tomography  

CERN Document Server

Network tomography aims at inferring internal network characteristics based on measurements at the edge of the network. In loss tomography, in particular, the characteristic of interest is the loss rate of individual links. There is a significant body of work dedicated to this problem using multicast and/or unicast end-to-end probes. Independently, recent advances in network coding have shown that there are several advantages from allowing intermediate nodes to process and combine, in addition to just forward, packets. In this paper, we pose the problem of loss tomography in networks that have network coding capabilities. We design a framework for estimating link loss rates, which leverages network coding capabilities and we show that it improves several aspects of tomography, including the identifiability of links, the tradeoff between estimation accuracy and bandwidth efficiency, and the complexity of ...

2010-01-01

98

{sup 18}F-labeled styrylpyridines as PET agents for amyloid plaque imaging  

Energy Technology Data Exchange (ETDEWEB)

Positron emission tomography (PET) imaging of {beta}-amyloid (A{beta}) plaques in the brain is a potentially valuable tool for studying the pathophysiology of Alzheimer's disease (AD). It may also be applicable for measuring the effectiveness of therapeutic drugs aimed at lowering A{beta} plaques in the brain. We have successfully reported a series of {sup 18}F-labeled fluoropegylated stilbenes for PET imaging studies. Encouraging results clearly demonstrated the usefulness of {sup 18}F-labeled stilbenes as potential A{beta} plaque-imaging agents. In the present study, we applied a similar approach to a styrylpyridine backbone structure. Among all derivatives examined (E)-2-(2-(2-(2-fluoroethoxy)ethoxy)ethoxy)-5-(4-dimethylaminostyryl) -pyridine (2) displayed high binding affinity in postmortem AD brain homogenates (K {sub i}=2.5{+-}0.4 nM, with [{sup 125}I]IMPY as radioligand). No-carrier-added [{sup 18}F]2 was successfully prepared ...

2007-01-15

99

Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques  

International Nuclear Information System (INIS)

Positron emission tomography (PET) is a fully quantitative technology for imaging metabolic pathways and dynamic processes in vivo. Attenuation correction of raw PET data is a prerequisite for quantification and is typically based on separate transmission measurements. In PET/CT attenuation correction, however, is performed routinely based on the available CT transmission data. Recently, combined PET/magnetic resonance (MR) has been proposed as a viable alternative to PET/CT. Current concepts of PET/MRI do not include CT-like transmission sources and, therefore, alternative methods of PET attenuation correction must be found. This article reviews existing approaches to MR-based attenuation correction (MR-AC). Most groups have proposed MR-AC algorithms for brain PET studies and more recently also for torso PET/MR imaging. Most MR-AC strategies require the use of complementary MR and transmission images, or morphology templates generated from ...

2009-03-01

100

Synthesis and PET imaging of the benzodiazepine receptor tracer [N-methyl-"1"1C]iomazenil  

International Nuclear Information System (INIS)

The central benzodiazepine receptor tracer [N-methyl-"1"1C]iomazenil (Ro 16-0154) was synthesized by alkylation of the desmethyl precursor noriomazenil with ["1"1C]methyl iodide. The ["1"1C]CH_3I (prepared by reduction of ["1"1C]CO_2 with LiAlH_4 followed by reaction with HI) was reacted with noriomazenil inN,N -dimethylformamide and Bu_4N"+OH"- for 1 min at 80 deg. C and purified by HPLC (C_1_8, 34% CH_3CN/H_2O, 7 mL/min). The product was obtained with synthesis time 35 #+-# 5 min (mean #+-# SD, n = 7), radiochemical yield (EOB) 36 #+-# 16%, radiochemical purity 99 #+-# 1%, and specific activity 5100 #+-# 2800 mCi/#mu#mol. Absorbed radiation doses were calculated from previously acquired human biodistribution data. The urinary bladder wall received the highest dose (0.099 mGy/MBq) for 4.8 h voiding interval and the effective dose equivalent was 0.015 mSv/MBq. After i.v. injection of ["1"1C]iomazenil in an adult baboon or healthy human volunteer, radioactivity accumulated in the cortex ...

1995-07-01

101

Single-pass high-gain free electron laser electron beam diagnostics  

International Nuclear Information System (INIS)

Consensus reached in the last few years that fourth generation light source will most likely be a X-ray or a UV coherent source based on single-pass high-gain free electron laser (FEL), such as Self Amplified Spontaneous Emission (SASE), or seeded high-gain harmonic-generation (HGHG) free electron lasers. High-gain (>10"7) required for single-pass FEL puts great constrain on the quality of electron beam, and demands detailed distribution information of electron beam in six-dimension. The typical accelerator system for single-pass FEL consists of a photocathode RF gun injection system, a linac and magnetic bunch compressors, and a long undulator. The major challenges in beam diagnostics for single-pass FEL are to characterize the pico-seconds high-brightness electron beam in six-dimension produced by photocathode RF gun injector, and improve the stability and reliability of the photocathode RF gun injection system. Characterization of short electron bunch ...

2000-11-27

102

Should coronary angiography be the gold standard? A study correlating thallium myocardial scintigraphy, translesional pressure gradient and percent stenosis  

International Nuclear Information System (INIS)

Coronary angiography provides anatomical information whereas thellium myocardial scintigraphy measures resistive tissue perfusion. Because of this fundamental difference. The authors question the validity of using coronary angiography as the gold standard to judge thellium myocardial scintigraphy. The authors studied 20 patients undergoing elective percutaneous coronary angioplasty who fulfilled the following criteria: (1) history of chest pain; (2) angiographically significant single vessel disease (>50% stenosis); (3) no prior myocardial infarction. All patients underwent maximal exercise thallium single photon emission computed tomography (T1-SPECT). Tl-SPECT was scored visually according to a 0 to 3 scale (0=absent uptake; 1=markedly decreased uptake; 2=minimally decreased uptake; 3=normal uptake). Translesional gradient and percent stenosis were measured before and after angioplasty. The authors found that significant linear ...

1985-06-02

103

Pre-therapy 18F-FDG PET quantitative parameters help in predicting the response to radioimmunotherapy in non-Hodgkin lymphoma  

International Nuclear Information System (INIS)

Radioimmunotherapy (RIT) is a new treatment option for patients with non-Hodgkin lymphoma (NHL). Response to RIT currently remains difficult to predict using conventional prognostic factors and could be refined using functional imaging. The goal of this work is to evaluate the value of 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET) in predicting response to Yttrium 90-labeled monoclonal antibodies for patients with NHL. Thirty-five patients with NHL who had undergone 18F-FDG PET prior to RIT with either 90Y-ibritumomab tiuxetan (group A; n=17) or 90Y-epratuzumab tetraxetan (group B; n=18) were included in this retrospective study. Four functional criteria were determined for each tumour lesion in a given patient: maximum and mean standard uptake values (SUVmax and SUVmean), functional lesion volume (LVol) and total lesion glycolysis (TLG, product of the volume and the SUVmean). For each patient, we determined highest SUVmax and ...

2010-03-01

104

Outcome of moderately dosed radiosurgery for limited brain metastases. Report of a single-center experience  

International Nuclear Information System (INIS)

Purpose: Efficacy and safety of the own single-center experience with moderately dosed radiosurgery (SRS) for limited (one to four) brain metastases were analyzed and correlated with patient- and treatment-related variables. Patients and Methods: Between 05/1998 and 10/2006, 93 patients received SRS for a total of 142 brain metastases. The median number of brain metastases treated per patient was one (range, one to four). 46 patients (49%) received initial SRS alone, 13 patients (14%) SRS with up-front whole-brain radiotherapy (WBRT), and 34 patients (37%) SRS for recurrent metastases after WBRT. Median dose was 16 Gy (range, 10-20 Gy). Results: Median overall survival (OS) was 7.5 months. The actuarial 6- and 12-month data for OS were 60% and 35%, for local brain control (LBC) 87% and 79%, and for distant brain control (DBC) 48% and 37%, respectively. Only ten of 46 patients (22%) with initial SRS alone ultimately received WBRT. Ten patients suffered from seizures within 3 months ...

2010-02-01

105

Model of blood-brain transfer of oxygen explains nonlinear flow-metabolism coupling during stimulation of visual cortex.  

DEFF Research Database (Denmark)

The coupling between cerebral metabolic rate of oxygen (CMRO2) and blood flow (CBF) in response to visual stimulation was evaluated by means of a model of oxygen delivery. The model predicted a nonlinear relationship between stimulus-evoked changes of oxygen consumption and blood flow. The magnitude of the CMRO2/CBF ratio index (IO2) was used to indicate the degree of flow-metabolism coupling prevailing in specific areas of the brain during physiological stimulation. Therefore, the index provided a measure of the blood oxygenation level dependent (BOLD) magnetic resonance contrast. To evaluate the changes of IO2 in response to visual stimulation, the model was applied to the effect of a changing flicker rate of a visual stimulus on the magnitudes of CBF, CMRO2, and oxygen diffusion capacity, in the human brain. Positron emission tomography (PET) was used to measure the CBF and the CMRO2 in 12 healthy volunteers who viewed a cross-hair ...

2000-01-01

106

Lesion localization in patients with hyperparathyroidism using double-phase Tc-99m MIBI parathyroid scintigraphy  

International Nuclear Information System (INIS)

This study was performed to evaluate the diagnostic usefulness of double-phase Tc-99m MIBI parathyroid scintigraphy with single photon emission computed tomography (SPECT) in patients with hyperparathyroidism. We also evaluated the relationship between Tc-99m MIBI uptake and oxyphil cell contents in parathyroid glands. The subjects were 28 parathyroid glands of 10 patients who underwent Tc-99m MIBI parathyroid scintigraphy and parathyroidectomy for clinically suspected hyperparathyroidism. Early and delayed pinhole images were obtained at 15 minutes and 2 hours after injection of Tc-99m MIBI, and SPECT images were followed. The weight and oxyphil cell contents of parathyroid tissue were obtained from pathologic specimen, and the scintigraphic findings were compared with histopathology. In surgical histopathology, 6 parathyroid adenomas and 9 parathyroid hyperplasias were confirmed. The sensitivity, specificity, and positive predictive value of ...

1999-02-01

107

Kinetic analysis of transport and opioid receptor binding of ( sup 3 H)(-)-cyclofoxy in rat brain in vivo: Implications for human studies  

Energy Technology Data Exchange (ETDEWEB)

(3H)Cyclofoxy (CF: 17-cyclopropylmethyl-3,14-dihydroxy-4,5-alpha-epoxy-6-beta-fluoromorp hinan) is an opioid antagonist with affinity to both mu and kappa subtypes that was synthesized for quantitative evaluation of opioid receptor binding in vivo. Two sets of experiments in rats were analyzed. The first involved determining the metabolite-corrected blood concentration and tissue distribution of CF in brain 1 to 60 min after i.v. bolus injection. The second involved measuring brain washout for 15 to 120 s following intracarotid artery injection of CF. A physiologically based model and a classical compartmental pharmacokinetic model were compared. The models included different assumptions for transport across the blood-brain barrier (BBB); estimates of nonspecific tissue binding and specific binding to a single opiate receptor site were found to be essentially the same with both models. The nonspecific binding equilibrium constant varied modestly in different brain structures (Keq = ...

1991-03-01

108

In vitro assessment of the agonist properties of the novel 5-HT_1_A receptor ligand, CUMI-101 (MMP), in rat brain tissue  

International Nuclear Information System (INIS)

Introduction: Development of agonist positron emission tomography (PET) radioligands for the 5-HT neurotransmitter system is an important target to enable the understanding of human 5-HT function in vivo. ["1"1C]CUMI-101, proposed as the first 5-HT_1_A receptor agonist PET ligand, has been reported to behave as a potent 5-HT_1_A agonist in a cellular system stably expressing human recombinant 5-HT_1_A receptors. In this study, we investigate the agonist properties of CUMI-101 in rat brain tissue. Methods: ["3"5S]-GTP#gamma#S binding studies were used to determine receptor function in HEK (human embryonic kidney) 293 cells transfected with human recombinant 5-HT_1_A receptors and in rat cortex and rat hippocampal tissue, following administration of CUMI-101 and standard 5-HT1A antagonists (5-HT, 5-CT and 8-OH-DPAT). Results: CUMI-101 behaved as an agonist at human recombinant 5-HT_1_A receptors (pEC_5_0 9.2). However, CUMI-101 did not show ...

2011-02-01

109

Dopamine transporter density in the basal ganglia assessed with [{sup 123}I]IPT SPET in children with attention deficit hyperactivity disorder  

Energy Technology Data Exchange (ETDEWEB)

Attention deficit hyperactivity disorder (ADHD) is a psychiatric disorder in childhood that is known to be associated with dopamine dysregulation. In this study, we investigated dopamine transporter (DAT) density in children with ADHD using iodine-123 labelled N-(3-iodopropen-2-yl)-2&beta;-carbomethoxy-3&beta;-(4-chlorophenyl) tropane ([{sup 123}I]IPT) single-photon emission tomography (SPET) and postulated that an alteration in DAT density in the basal ganglia is responsible for dopaminergic dysfunction in children with ADHD. Nine drug-naive children with ADHD and six normal children were included in the study. We performed brain SPET 2 h after the intravenous administration of [{sup 123}I]IPT and carried out both quantitative and qualitative analyses using the obtained SPET data, which were reconstructed for the assessment of the specific/non-specific DAT binding ratio in the basal ganglia. We then investigated the correlation ...

2003-02-01

110

Different "1"8F-FDG Uptake According to Tumor Location and Morphology of Cholangiocarcinoma and Its Clinical Implication  

International Nuclear Information System (INIS)

"1"8F-fluorodeoxyglucose (FDG) uptake on positron emission tomography (PET) scan has been found to reflect tumor aggressiveness and prognosis in various types of cancer. However, pattern of FDG uptake in biliary malignancies and its clinical significance have not been studied well. The purpose of this study was to assess the additional value of "1"8F-FDG PET in differential diagnosis and prognosis of cholangiocarcinoma (CC) according to the tumor location and tumor morphology. From April 2005 to May 2008, eighty two patients (M:F=55:27, age 66.2#+-#9.6 yrs) with CC underwent "1"8F-FDG PET. For semiquantitative analysis, the maximum standardized uptake value (SUV_m_a_x) was obtained from the primary tumor. The difference of SUV_m_a_x according to the tumor location and tumor growth pattern, such as scirrhous type, nodular type, polypoid type were compared. Overall sensitivity of PET scan was 81.7% in CC. SUV_m_a_x on PET scan in intrahepatic CC ...

2009-08-01

111

Development of regional cerebral blood flow during childhood studied with Iodine-123-IMP SPECT  

International Nuclear Information System (INIS)

Regional cerebral blood flow (rCBF) was assessed with single photon emission computed tomography (SPECT), "1"2"3I-N-isopropyl-iodoamphetamine ("1"2"3I-IMP), and the Table-Look-Up method in 51 children (27 boys, 24 girls) considered neurologically normal and aged 1 month to 15 years (mean age, 4 years 1 month; standard deviation (SD) 3 years 11 months) divided into seven age groups. The rCBF was measured in cortical regions, the cerebellum, thalamus, and the head of the caudate nucleus. Curves for reference values and standard deviations were defined for each region. The rCBF rapidly increased until 2 years of age, reaching maximum values during the third to fifth periods (2 to 10 years of age) in each region. The rCBFs then decreased, reaching adult levels at 10 to 15 years of age. The rCBF reached maximum values later in the frontal region than in other regions. The rCBF during the early period increased most prominently in the occipital ...

2006-06-01

112

Correlation of angiogenesis with "1"8F-FMT and "1"8F-FDG uptake in non-small cell lung cancer  

International Nuclear Information System (INIS)

L-[3-"1"8F]-#alpha#-methyltyrosine ("1"8F-FMT) is an amino-acid tracer for positron-emission tomography (PET). We have conducted a clinicopathologic study to elucidate the correlation of angiogenesis with "1"8F-FMT and 2-["1"8F]-fluoro-2-deoxy-D-glucose ("1"8F-FDG) uptake in patients with non-small cell lung cancer (NSCLC). Thirty-seven NSCLC patients were enrolled in this study, and two PET studies with "1"8F-FMT and "1"8F-FDG were performed. Uptake of PET tracers was evaluated with standardized uptake value. Vascular endothelial growth factor (VEGF), CD31, CD34, L-type amino acid transporter 1 (LAT1) and Ki-67 labeling index of the resected tumors were analyzed by immunohistochemical staining, and correlated with the clinicopathologic variables and the uptake of PET tracers. The median VEGF rate was 45% (range, 10-78%). High expression was seen in 30 patients (81%, 30/37). VEGF expression was statistically associated with progressively ...

2009-04-01

113

Comparison of /sup 99/Tcsup(m) complexes (NEP-DADT, ME-NEP-DADT and HMPAO) with /sup 123/IAMP for brain SPECT imaging in dogs  

Energy Technology Data Exchange (ETDEWEB)

In this study we have compared brain uptake and blood clearance of /sup 99/Tcsup(m)-N-ethylpiperi-dinediamino dithiol (/sup 99/Tcsup(m)-NEP DADT), its 4-methylated derivative (/sup 99/Tcsup(m)-Me-NEP-DADT) and /sup 99/Tcsup(m)-hexamethyl-propylene-amine-oxime (/sup 99/Tcsup(m)-HMPAO) with that of N-isopropyl(/sup 123/I)iodoamphetamine (/sup 123/IAMP) in two dogs. Single photon emission tomography (SPECT) was employed to measure brain accumulation and retention of the four radiopharmaceuticals. Cerebral uptake of the /sup 99/Tcsup(m) complexes was lower than that of /sup 123/IAMP. There was considerable extracerebral activity in the dog's head, especially in the olfactory and snout regions. Because of slow blood clearance, /sup 99/Tcsup(m)-HMPAO showed high uptake in these regions. Brain uptake of /sup 99/Tcsup(m)-HMPAO reached a plateau 5 to 10 min after intravenous injection and remained constant for the entire study period (1 h). ...

1987-08-01

114

Calibration of the Capintec CRC-712M dose calibrator for "1"8F  

International Nuclear Information System (INIS)

Primary standardisation was performed on a solution of "1"8F using the 4#pi##beta#-#gamma# coincidence counting efficiency-tracing extrapolation method with "6"0Co used as a tracer nuclide. The result was used to calibrate the ANSTO secondary standard ionisation chamber which is used to disseminate Australian activity standards for gamma emitters. Using the secondary activity standard for "1"8F, the Capintec CRC-712M dose calibrator at the Australian National Medical Cyclotron (NMC) Positron Emission Tomography (PET) Quality Control (QC) Section was calibrated. The dial setting number recommended by the manufacturer for the measurement of the activity of "1"8F is 439. In this work, the dial setting numbers for the activity measurement of the solution of "1"8F in Wheaton vials were experimentally determined to be 443+/-12, 446+/-12, 459+/-11, 473+/-15 for 0.1, 1, 4.5 and 9ml solution volumes, respectively. The uncertainties given above are ...

2006-04-01

115

Attention deficit hyperactivity disorder: binding of [{sup 99m}Tc]TRODAT-1 to the dopamine transporter before and after methylphenidate treatment  

Energy Technology Data Exchange (ETDEWEB)

Involvement of the dopaminergic system has been suggested in patients suffering from attention deficit hyperactivity disorder (ADHD) since the symptoms can be successfully treated with methylphenidate, a potent blocker of the dopamine transporter (DAT). This study reports the findings on the status of the DAT in adults with ADHD before and after commencement of treatment with methylphenidate, as measured using [{sup 99m}Tc]TRODAT-1. Seventeen patients (seven males, ten females, aged 21-64 years, mean 38 years) were examined before and after the initiation of methylphenidate treatment (3 x 5 mg/day). All subjects were injected with 800 MBq [{sup 99m}Tc]TRODAT-1 and imaged 3 h p.i. Single-photon emission tomography (SPET) scans were acquired using a triple-headed gamma camera. For semi-quantitative evaluation of the DAT, transverse slices corrected for attenuation were used to calculate specific binding in the striatum, with the cerebellum used ...

2000-10-01

116

A high-sensitivity small animal SPECT system  

International Nuclear Information System (INIS)

Medical imaging using single gamma-ray-emitting radionuclides typically makes use of parallel hole collimators or pinholes in order to achieve good spatial resolution. However, a tradeoff in sensitivity is inherent in the use of a collimator, and modern preclinical single photon emission computed tomography (SPECT) systems detect a very small fraction of emitted gamma rays, often less than 0.1%. A system for small animal SPECT imaging which uses no collimators could potentially achieve very high sensitivity-several tens of percent-with reasonably sized detectors. This would allow two significant improvements in preclinical studies: images could be obtained more rapidly, allowing higher throughput for screening applications, or for dynamic processes to be observed with very good time resolution; and images could be obtained with less radioactive tracer, making possible the in vivo imaging of low-capacity receptor systems, aiding research into ...

2009-03-07

117

Industrial emissions of 1,3-butadiene.  

UK PubMed Central (United Kingdom)

Sources of industrial emissions of 1,3-butadiene are discussed both by process (production, consumers) and type (equipment leaks, point sources). Quantification of the emissions are presented, as reported...Full Text Available

1990-06-01

118

Prediction of the compressive strength of vertebral bodies of the lumbar spine by quantitative computed tomography.  

Science.gov (United States)

The ultimate compressive strength of 36 thoracolumbar vertebrae was determined experimentally. In addition, the trabecular bone mineral content was measured by single energy quantitative computed tomography. The areas of fractured endplates were also determined by computed tomography. The results show that a linear relationship exists between the compressive strength and the product of bone density and endplate area. These data allow an in vivo prediction of vertebral body strength using a noninvasive method with a standard error of estimate amounting to less than 0.95 kN. PMID:3212488

1988-01-01

119

Computerized tomography of adrenal glands in the investigation of Cushing's syn  

International Nuclear Information System (INIS)

Computerized tomography of the adrenal glands was performed in 10 patients with Cushing's syndrome using a G.E. 8800 CT/T Body Scanner. The tomographic findings of unilateral adrenal masses in 4 patients were confirmed by surgery. In the remaining 6 patients, computerized tomography did not identify any masses, and both glands were well visualized and showed normal shape. In these patients, measurement of the adrenal glands revealed both normal (n=1) and enlarged glands (n=5). The findings of adrenalectomy (n=4) or transphenoidal surgery and follow-up (n=2) established the diagnosis of adrenal phyperplasia in all patients. (Author).

120

Transurethral Ultrasound Diffraction Tomography  

Science.gov (United States)

... [5] GT Gullberg, RH Huesman, DNG Roy, J. Qi and BW Reutter, Esti- mation of the parameter covariance matrix for a one-compartment cardiac ...

2007-03-01

121

Quantitative cerebral blood flow with Optical Coherence Tomography  

UK PubMed Central (United Kingdom)

Absolute measurements of cerebral blood flow (CBF) are an important endpoint in studies of cerebral pathophysiology. Currently no accepted method exists for in vivo longitudinal...Full Text Available

2010-02-01

125

Diagnostic Value of C-reactive Protein in Complicated Appendicitis  

UK PubMed Central (United Kingdom)

PurposeEarly detection of appendicitis has increased due to development of computed tomography and ultrasonography, yet we are frequently meeting complicated appendicitis, including...Full Text Available

2011-06-01

126

Computer tomographic diagnosis of intrathoracic lipoma  

Energy Technology Data Exchange (ETDEWEB)

A case of intrathoracic lipoma in a child is presented. The diagnosis was made before operation by means of computer-assisted tomography, a non-interventional procedure.

1984-04-14

127

Computed Tomography diagnosis of skeletal involvement in multiple myeloma  

International Nuclear Information System (INIS)

The authors assess the role of Computed Topography in the diagnosis and management of multiple myeloma (MM) and investigate if Computed Tomography findings can influence the clinical approach, prognosis and treatment. 273 multiple myeloma patients submitted to Computed Tomography June 1994, to December, 1996. The patients were 143 men and 130 women (mean age: 65 years): 143 were stage I, 38 stage II and 92 stage III according to Durie and Salomon's clinical classification. All patients were submitted to blood tests, spinal radiography and Computed Tomography, the latter with serial 5-mm scans on several vertebral bodies. Computed Tomography despicted vertebral arch and process involvement in 3 cases with the vertebral pedicle sign. Moreover, Computed Tomography proved superior to radiography in showing the spread of myelomatous masses into the soft tissues in a case with solitary ...

1994-06-01

129

Carbon Trading with Imperfectly Observable Emissions  

Energy Technology Data Exchange (ETDEWEB)

The Kyoto Protocol foresees emission trading but does not yet specify verification of (uncertain) emissions. This paper analyses a setting in which parties can meet their emission targets by reducing emissions, by investing in monitoring (reducing uncertainty of emissions) or by (bilaterally) trading permits. We derive the optimality conditions and carry out various numerical simulations. Our applications suggest that including uncertainty could increase compliance costs for the USA, Japan and the European Union. Central Europe and the Former Soviet Union might be able to gain from trading due to higher permit prices. Emissions trading could also lower aggregate uncertainty on emissions.

2003-06-01

130

Advanced Thermal Management for Military Application  

Science.gov (United States)

... management. 5.3 Decreased Emissions Changes in engine emission regulations are driving engine technology development. A ...

2004-12-01

131

Significance of cranial computer tomography for the early diagnosis of peri- and postnatal damage  

Energy Technology Data Exchange (ETDEWEB)

It is reported on examination-technical possibilities with craniocerebral Computer Tomography in the peri- and postnatal period. Some typical tomographic images from a 17 1/2 months period in our own patient material of 327 children are demonstrated. The special advantages of this new technical-extensive method are: exact diagnoses, observation possibility of the longitudinal section, and the absolute harmlessness to the child.

1981-01-01

132

Selection of dimensions of scintillation detectors and of the correction energy with the use of the dual energy method in computerized tomography  

Science.gov (United States)

The article explains the method of selecting the optimum energy for correcting the energy selectivity of tomographic projection and the optimum length of the crystals corresponding to it when the dual energy method in computerized tomography is used. Results of numerical calculations for actual materials and count results are presented.

1986-05-01

133

Incidental orbital calcifications on computed tomography scans; Calcificacoes orbitarias incidentais na tomografia computadorizada  

Energy Technology Data Exchange (ETDEWEB)

We retrospectively studied the computed tomography scans of the orbit in 75 patients in order to identify the presence of incidental calcifications (scleral and trochlear apparatus calcifications.). These imaging findings should integrate the vast list of differential diagnosis of orbital calcifications, as they may help radiologists to distinguish these calcifications from orbital foreign bodies. (author)

2001-02-01

134

From tomography to voludensitometry: radiation detectors for industrial control and medical instrumentation; De la tomographie a la voludensitometrie: les capteurs pour le controle industriel et l`instrumentation medicale  

Energy Technology Data Exchange (ETDEWEB)

In this article, the author presents the main technological solutions, available or in development, on X-ray detectors in order to obtain a digital image in biomedical radiography or in industrial radiography: linear x-ray detectors and bidimensional x-ray detectors (memory radioluminescent screens, matrix plan detectors).

1993-12-01

135

Estimation of errors provided with dead times of roentgen digital tomography  

International Nuclear Information System (INIS)

Impact of apparatus dead time on the accuracy of measurement of radial distribution of the radiation attenuation factor in the roentgen computer tomography for rotation bodies is studied. Analytical expressions are obtained. Calculations of the threshold loads for radiometric detectors, providing for the accuracy of measurement at the stage of designing the tomographic complex detecting unit, are obtained

136

Differential diagnosis of tumorous lesions in the iliac bone in children  

Energy Technology Data Exchange (ETDEWEB)

The radiologic appearance of inflammatory and tumorous lesions in the iliac bone is characterized by destructive alterations and consolidations simultaneously. This pattern is nonspecific. The value of plain films of this area is compromised by the anatomy of the iliac bone and by overlying structures. Therefore tomography, computer tomography and bone scans are necessary. Difficulties in differentiation between benign and malignant lesions are discussed and case reports are given. The importance of histologic examination is stressed.

1984-02-01

137

Detection of drugs and explosives using neutron computerized tomography and artificial intelligence techniques  

International Nuclear Information System (INIS)

In this study the development of a methodology to detect illicit drugs and plastic explosives is described with the objective of being applied in the realm of public security. For this end, non-destructive assay with neutrons was used and the technique applied was the real time neutron radiography together with computerized tomography. The system is endowed with automatic responses based upon the application of an artificial intelligence technique. In previous tests using real samples, the system proved capable of identifying 97% of the inspected materials.

2010-06-01

138

Computer tomography of orbita in children  

Energy Technology Data Exchange (ETDEWEB)

The experiences are described of the examination of orbita in children using computer tomography (CT). Over a period of four years 42 examinations were performed of children in the age ranging between 7 months and 15 years, i.e., 2.7 percent of all CT examinations performed. The highest diagnostic yield was in orbita tumours. The possibilities of CT are demonstrated on examples.

1983-07-01

139

Computed tomography in migratory disorders of human brain development  

International Nuclear Information System (INIS)

Computed tomographic findings in developmental brain anomalies are more easily classified when the system used is based on embryogenesis related to morphology. Analysis of computed tomographic findings in a series of 154 patients with brain anomalies (Chiari malformation not included) revealed that specific examples of abnormalities occurring in major stages of brain development may be recognized by computed tomography. This paper deals with a group of patients with abnormalities that reflect a disturbance in neuronal migration. (orig.).

140

Computed tomography - old ideas and new technology  

International Nuclear Information System (INIS)

Several recently introduced 'new' techniques in computed tomography - iterative reconstruction, gated cardiac CT, multiple-source, and dual-energy CT - actually date back to the early days of CT. We review the historic origins and evolution of these techniques, which may provide some insight into the latest innovations in commercial CT systems. (orig.)

2011-03-01

141

Compton scatter tomography and its inversion using a few projections  

Energy Technology Data Exchange (ETDEWEB)

Compton scatter tomography utilizes the electronic collimation characteristics available through the Compton scattering angle-energy correlation to obtain tomographic images. In this work we present particular aspects of the technique, which are relevant to the inverse radiation transport problem of reducing marginal projection data to radial two-phase flow regime maps. The results indicate a viable technique for the tomographic imaging of tow-phase flow using practical source strengths and reasonably few detectors.

1988-01-01

142

Seismic tomography inversion in the case that sources and receivers are distributed out of a 2-D plane; Shingen jushinten ga nijigen heimennai ni nai baai no danseiha tomography kaiseki ni kansuru kosatsu  

Energy Technology Data Exchange (ETDEWEB)

In the case where sources and receivers are not distributed on a 2-D plane, seismic tomography inversion was studied. In tomography experiments, the existing wells are generally used. In such case, sources and receivers are frequently not distributed on a 2-D plane. The 2.5-D analysis method including 2-D structure and 3-D ray-tracing was thus developed. This method is featured by less memory necessary for ray-tracing calculation, and the same algorithm for velocity determination as 2-D analysis method. In previous methods, since analysis is generally carried out by projecting sources and receivers on a certain assumed 2-D plane, it can derive correct results in the case of constant velocity and straight ray, however, in the other case, it derives incorrect results. Application of 3-D tomography requires a large amount of memory, and falls into poor convergence because of various parameters. The 2.5-D analysis method can ...

1996-10-01

143

Uptake of radiolabeled ions in normal and ischemia-damaged brain  

Energy Technology Data Exchange (ETDEWEB)

The regional concentrations of nine radiochemicals were measured in rat brain after induction of cerebral ischemia to identify tracers concentrated by brain undergoing selective neuronal necrosis. Transient (30 minute) forebrain ischemia was produced in the rat; 24 hours after cerebral recirculation the radiochemicals were injected intravenously and allowed to circulate for 5 hours. The brain concentrations of the radiochemicals in dissected regions were determined by scintillation counting. Forebrain ischemia of this nature will produce extensive injury to striatal neurons but will spare the great majority of neocortical neurons at 24 hours. The regional concentrations of these radiochemicals varied considerably in both control and ischemic animals. In postischemic animals, 4 radionuclides (/sup 63/Ni, /sup 99/TcO/sub 4/, /sup 22/Na, and (/sup 3/H)tetracycline) were concentrated in the irreversibly damaged striatum in amounts ranging from 1.4 to 2.4 times greater than in normal ...

1986-05-01

144

Investigation into {sup 64}Cu-labeled Bis(selenosemicarbazone) and Bis(thiosemicarbazone) complexes as hypoxia imaging agents  

Energy Technology Data Exchange (ETDEWEB)

Background: Cu-diacetyl-bis(N{sup 4}-methylthiosemicarbazone) [Cu-ATSM], although excellent for oncology applications, may not be suitable for delineating cardiovascular or neurological hypoxia. For this reason, new Cu hypoxia positron emission tomography (PET) imaging agents are being examined to search for a higher selectivity for hypoxic or ischemic tissue at higher oxygen concentrations found in these tissues. Two approaches are to increase alkylation or to replace the sulfur atoms with selenium, resulting in the formation of selenosemicarbazones. Methods: Three {sup 64}Cu-labeled selenosemicarbazone complexes were synthesized and one was screened for hypoxia selectivity in vitro using EMT-6 mouse mammary carcinoma cells. Rodent biodistribution and small animal PET images were obtained from BALB/c mice implanted with EMT-6 tumors. One alkylated thiosemicarbazone was synthesized and examined. Results: Of the three bis(selenosemicarbazone) ...

2005-02-01

145

Integration of SPECT with CT to plan radiotherapy fields. n application to conformal irradiation for lung carcinoma; Integrazione delle immagini della Tomografia Computerizzata con emissione di fotone singolo in un sistema commerciale per l'elaborazione dei piani di radioterapia. Applicazione all'irradiazione conformazionale del carcinoma polmonare  

Energy Technology Data Exchange (ETDEWEB)

Single photon emission computed tomography (SPECT) of lung perfusions permits to map functioning lung parenchyma with higher sensitivity than CT. Delivering higher radiations doses it used to increase local control in lung carcinoma; this strategy is based on radiobiological and clinical studies. Lung parenchyma is a dose-limiting tissue in patients irradiated for lung cancer. Functional mapping based on SPECT and CT findings permits to design radiation beams such as to minimize irradiation of functioning lung. [Italian] L'integrazione delle immagini diagnostiche aventi diverso contenuto informativo anatomico-funzionale puo' essere utilizzata nella radioterapia per migliorare le procedure diagnostiche e ottimizzare la geometria dell'irraggiamento. I sistemi per l'elaborazione di piani di radioterapia oggi in uso sono direttamente interfacciati con gli apparecchi di Tomografia Computerizzata (TC) e ...

1999-04-01

146

Immunoscintigraphy with anti-225.28S for ocular melanoma - a comparison with histology and immunohistochemistry  

Energy Technology Data Exchange (ETDEWEB)

Aim: The purpose of this prospective study was to evaluate the value of immunoscintigraphy (ISG) with anti-225.28S in clinically suspected ocular melanoma. Methods: For this purpose standardized ISG was performed in 36 patients using both planar acquisition and emission computed tomography (ECT). Ocular melanoma was present in 31 patients. In 21 patients therapy was enucleation of the eye. These specimens were evaluated by histology and immunohistochemistry in 11 of 21 patients. Results: Regarding the clinical diagnosis, ISG was positive only in 15 of 31 patients with ocular melanoma, regarding histology in 11 of 21 and regarding immunohistochemistry in 5 of 6 patients with a positive immunoreaction. 5 patients showed no immunoreactivity, their ISG was negative. Conclusion: Thus a good correlation between ISG and immunohistochemistry was observed. However ISG using the cutaneous melanoma antibody 225.28S cannot be recommended for the diagnostic ...

1997-03-01

147

Controlling transit-bus emissions and improving management  

Energy Technology Data Exchange (ETDEWEB)

The 8 papers in the report deal with the following areas: Introduction to diesel particulate emissions, alternative fuels, and the transit industry; Technical problems and policy issues associated with the 1991 bus emissions standards; Reducing transit bus emissions: comparative costs and benefits of methanol, particulate traps, and fuel modification; Effects of applying emissions averaging, trading, and banking to transit buses; Strategic review of heavy-duty engine emission regulations and alternate fuels; Meeting bus emissions standards--a perspective; Economic evaluation of bus maintenance contracting; Objectives for a transit-bus-fleet management data, information, and knowledge exchange.

1988-01-01

148

Better technologies for the measurement, regulation and control of kiln emissions; Ameliorations des technologies de mesure, regulation et controle des emissions des fours  

Energy Technology Data Exchange (ETDEWEB)

The resulting emissions of the firing of ceramic products of all type are described, the factors are enumerated to diminish the emissions in the kilns and the technologies applied in the kilns to reduce these emissions while carrying out energy saving are described briefly. (author)

2005-11-15

149

Computerized Tomography versus unenhanced and enhanced fast MRI sequences in the study of liver metastases: Qualitative and quantitative analyses  

International Nuclear Information System (INIS)

The authors compared unenhanced and contrast-enhanced fast MRI and Computerized Tomography in the detection of liver metastases. Eleven patients with single or multiple hepatic lesions (42 in all) were submitted to V and magnetic resonance studies; T1- and T2- weighted TSE, T2-weighted TSE with fat suppression, unenhanced breath-hold TFE and early or delayed enhanced breath-hold TFE images were acquired with a 1.5 T superconductive magnet (Philips NT). The quantitative analysis of all magnetic resonance images was performed for contrast/noise ratio (CNR) and number of detected lesions; magnetic resonance and Computerized Tomography images were also compared qualitatively for lesion conspicuity, anatomical structure identification and artifacts. The results were compared with Student's test. Early enhanced breath-hold TFE was statistically superior to T1-weighted TSE (p = .0009), T2-weighted TSE (p = .01) and Computerized ...

1997-01-01

150

Evaluation of bone mineral content using Quantitative Computed Tomography  

International Nuclear Information System (INIS)

The authors have evaluated bone mineral content in the vertebral spongiosa by means of Computed Tomography. The method proposed by Genant and Cann [17, 18] has been applied to examine 164 healthy volunteers and 108 patients. Both healthy males and females showed a progressive bone mineral loss increasing with age; the bone mineral loss was most severe in females during the 4th and 5th decade of life. Pathology included patients with osteoporotic fractures (vertebral and femural neck), patients with partial gastrectomy, renal failure, primary hyperparathyroidism, Cushing syndrome, corticosteroid therapy. Bone mineral values were significantly lower in most pathologic groups. Computed Tomography proves thus to be a valuable method to assess bone mineral content and to identify patients at risk for fractures.

1988-01-01

151

Results of Source Emissions Testing. UTC Fuel Cell Model ...  

Science.gov (United States)

... Results of Source Emissions Testing UTC Fuel Cell Model PC25C ... Results of Source Emissions Testing: UTC Fuel Cell Model PC25C ...

2004-09-01

152

Emissions and reduction of greenhouse gases from agriculture and food manufacturing -- A summary white paper  

Science.gov (United States)

This paper summarizes the current scientific and technological knowledge about greenhouse gas emissions from various agricultural practices and the manufacturing of food. The study also provides estimates that compare agriculture-related alternatives for reducing greenhouse gas emissions.

1999-12-01

153

Biogenic emissions of isoprenoids and NO in China and comparison to anthropogenic emissions  

International Nuclear Information System (INIS)

In this study, a regional dynamical model (WRF) is used to drive biogenic emission models to calculate high resolution (10 x 10 km) biogenic emissions of isoprene (C_5H_8), monoterpenes (C_1H_1_6), and nitric oxide (NO) in China. This high resolution biogenic inventory will be available for the community to study the effect of biogenic emissions on photochemical oxidants in China. The biogenic emissions are compared to anthropogenic emissions to gain insight on the potential impact of the biogenic emissions on tropospheric chemistry, especially ozone production in this region. The results show that the biogenic emissions in China exhibit strongly diurnal, seasonal, and spatial variations. The isoprenoid (including both isoprene and monoterpenes) emissions are closely correlated to tree density and strongly vary with ...

2006-12-01

154

Frequent Questions - Emissions | Climate Change | U.S. EPA  

Science.gov (United States)

activities, including the combustion of diesel fuel in heavy-duty vehicles and jet fuel in aircrafts. Current details on emissions from the transportation and other...

2011-04-14

155

An Intrinsic Baldwin Effect in the H Beta Broad Emission Line in the Spectrum of NGC 5548  

Science.gov (United States)

We investigate the possibility of an intrinsic Baldwin effect (i.e., nonlinear emission-line

2003-01-01

156

The Prevalence of Concha Bullosa and Nasal Septal Deviation and Their Relationship to Maxillary Sinusitis by Volumetric Tomography  

UK PubMed Central (United Kingdom)

The objective of this study was to determine the prevalence of concha bullosa and nasal septal deviation and their potential relationships to maxillary sinusitis. 883 CT scans taken at Creighton University...Full Text Available

2010-01-01

157

TLD assessment of mouse dosimetry during microCT imaging  

UK PubMed Central (United Kingdom)

Advances in laboratory animal imaging have provided new resources for noninvasive biomedical research. Among these technologies is microcomputed tomography (microCT) which is widely used to obtain high...Full Text Available

2008-09-01

158

Relation between frequency of seismic wave and resolution of tomography; Danseiha tomography kaiseki ni okeru shuhasu to bunkaino no kankei  

Energy Technology Data Exchange (ETDEWEB)

With regard to the elastic wave exploration, discussions have been given on the relationship between frequency and resolution in P-wave velocity tomography using the initial travel time. The discussions were carried out by using a new analysis method which incorporates the concept of Fresnel volume into tomography analysis. The following two arrangements were used in the calculation: a cross hole arrangement, in which seismic source and vibration receiving points were arranged so as to surround the three directions of a region extending 250 m in the horizontal direction and 500 m in the vertical direction, and observation is performed between two wells, and a permeation VSP arrangement in which the seismic source is installed on the ground surface and receiving points installed in wells. Restructuring was performed on the velocity structure by using a total of 819 observation travel times. This method has derived results of the restructuring ...

1997-05-27

159

Range accuracy in carbon ion treatment planning based on CT-calibration with real tissue samples  

UK PubMed Central (United Kingdom)

BackgroundThe precision in carbon ion radiotherapy depends on the calibration of Hounsfield units (HU) as measured with computed tomography (CT) to water equivalence. This calibration...Full Text Available

160

Quantification of lung surface area using computed tomography  

UK PubMed Central (United Kingdom)

ObjectiveTo refine the CT prediction of emphysema by comparing histology and CT for specific regions of lung. To incorporate both regional lung density measured by CT and cluster...Full Text Available

2010-01-01

161

Noise suppression in scatter correction for cone-beam CT  

UK PubMed Central (United Kingdom)

Scatter correction is crucial to the quality of reconstructed images in x-ray cone-beam computed tomography (CBCT). Most of existing scatter correction methods assume smooth scatter distributions. The...Full Text Available

2009-03-01

162

Fourier-Domain Optical Coherence Tomography and Adaptive Optics Reveal Nerve Fiber Layer Loss and Photoreceptor Changes in a Patient With Optic Nerve Drusen  

UK PubMed Central (United Kingdom)

BackgroundNew technology allows more precise definition of structural alterations of all retinal layers although it has not been used previously in cases of optic...Full Text Available

2008-06-01

163

Feature-based rectal contour propagation from planning CT to cone beam CT  

UK PubMed Central (United Kingdom)

The purpose of this work is to develop a novel feature-based registration strategy to automatically map the rectal contours from planning computed tomography (CT) (pCT) to cone beam CT (CBCT). The rectal...Full Text Available

2008-10-01

164

Evaluation of Tumor Micro-Environment in an Animal Model using a Nanoparticle Contrast Agent in Computed Tomography Imaging  

UK PubMed Central (United Kingdom)

RATIONALE AND OBJECTIVESNon-invasive longitudinal imaging of tumor vasculature could provide new insights into the development of solid tumors, facilitating efficient...Full Text Available

2011-01-01

165

Enhanced CT and CT virtual endoscopy in diagnosis of heterotopic pancreas  

UK PubMed Central (United Kingdom)

AIM: To improve the diagnosis of heterotopic pancreas by the use of contrast-enhanced computed tomography (CT) imaging and CT virtual endoscopy (CTVE).METHODS: A total of six patients with heterotopic...Full Text Available

2011-09-07

166

Effects of Age on Optical Coherence Tomography Measurements of Healthy Retinal Nerve Fiber Layer, Macula and Optic Nerve Head  

UK PubMed Central (United Kingdom)

PurposeTo determine the effects of age on global and sectoral peripapillary retinal nerve fiber layer (RNFL), macular thicknesses and optic nerve head (ONH) parameters...Full Text Available

2009-06-01

167

Characteristics of common solid liver lesions and recommendations for diagnostic workup  

UK PubMed Central (United Kingdom)

Due to the widespread clinical use of imaging modalities such as ultrasonography, computed tomography and magnetic resonance imaging (MRI), previously unsuspected liver masses are increasingly being...Full Text Available

2009-07-14

168

CT evaulation of thoracic and abdominal fatty masses  

International Nuclear Information System (INIS)

The diagnostic accuracy of computed tomography (CT) in several patterns of thoracic and abdominal fatty masses, has been examined. In selected cases our findings overlap the features of the recent literature. The possibility of surgical therapy in peculiar cases of adipose deposits, commonly esteemed benign, is considered.

1986-01-01

169

CLINICAL VALUE, NORMATIVE RETINAL SENSITIVITY VALUES, AND INTRASESSION REPEATABILITY USING A COMBINED SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY/SCANNING LASER OPHTHALMOSCOPE MICROPERIMETER  

UK PubMed Central (United Kingdom)

PurposeTo establish normative values for macular light sensitivity and to determine the intrasession fluctuation of perimetric responses using the OPKO/OTI microperimeter.Full Text Available

2011-02-01

170

Assessment of the value of various tomography modalities for diagnostic evaluation of the female genital system  

International Nuclear Information System (INIS)

The comprehensive survey explains the indications and the specific value of the modern tomographic modalities with respect to the various diagnostic issues. Numerous reproductions of CT, MRI, US scans illustrate the aspects discussed. (orig./CB)

2001-09-01

171

An unusual presentation of metastatic adenocarcinoma of lung: a case report  

UK PubMed Central (United Kingdom)

We report an unusual patient with primary adenocarcinoma of lung causing malignant pleural and pericardial effusions. The diagnosis was made only at autopsy as his staging computed tomography scan of...Full Text Available

172

A BPF-FBP tandem algorithm for image reconstruction in reverse helical cone-beam CT  

UK PubMed Central (United Kingdom)

Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image...Full Text Available

2010-01-01

173

Vascular injuries in intestinal obstruction. The role of computed tomography; Complicazioni vascolari nelle occlusioni intestinali: ruolo della tomografia computerizzata  

Energy Technology Data Exchange (ETDEWEB)

The paper investigates computerized tomography capabilities in showing vascular complications secondary to intestinal obstruction and for assessing the site and cause of obstruction. [Italian] Scopo del lavoro e' lo studio dell'uso della tomografia computerizzata nel riconoscimento di complicanze vascolari secondarie ad occlusione intestinale e della presenza, della natura e della sede dell'ostacolo alla canalizzazione intestinale.

1999-09-01

174

Three-dimensional cranio-facial computed tomography  

International Nuclear Information System (INIS)

Computed tomography allows today to reconstruct three-dimensional (eD) images fram axial scans. The authors report their experience in cranio-facial pathology achived in two Departments of Radiology (University of Trieste, Italy and University of Standford, California). 3D images have been realized using two different softwares, one of which allows to reconstruct both soft tissue and bone structures. The application in maxillo-facial traumas, cranio-facial malformations and head tumours are disscussed. 3D images turned out to be very useful for the optimal visualization and for the spatial demostration of the lesion and have potential applications in cranio-facial surgery and radiotherapy.

1986-01-01

175

The value of computed tomography in the diagnosis of grating scapula  

Energy Technology Data Exchange (ETDEWEB)

Snapping or grating scapula is a condition of the shoulder girdle in which the patient complains of pain and an audible snapping sound which may be associated with pain. We evaluated the diagnostic value of the computed tomography (CT) scans using the clinical diagnosis of a grating scapula as the gold standard. This retrospective study reports the sensitivity, specificity, likelihood ratio and receiver operator characteristic curve for the CT scans and the k value as a measure of the interobserver agreement. None of the parameters validated the examination. We therefore concluded that CT scans are inappropriate for differentiation between a grating scapula and a normally functioning shoulder except in cases where bony abnormalities are present. (orig.)

1994-07-01

176

Spiral CT with three-dimensional and multiplanar reconstruction in the diagnosis of anterior chest wall joint and bone disorders  

Energy Technology Data Exchange (ETDEWEB)

Twenty-seven patients with symptoms or clinical findings suggesting joint or bone disorders of the anterior chest wall (ACW) were evaluated by spiral CT with 3-dimensional (3-D) and multiplanar reconstructions. Preceding conventional ACW tomography was performed in 10 patients. ACW joint and bone changes were visualized more adequately by coronal 2-D reconstructions based on spiral CT than by conventional tomography. In addition, nonossified costal cartilages and soft tissue lesions were demonstrated. 3-D reconstructions sometimes added information, especially in patients with fracture and dislocation. (orig.).

1994-09-01

177

Organ doses to atomic bomb survivors during photofluorography, fluoroscopy and computer tomography  

Energy Technology Data Exchange (ETDEWEB)

Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).

1991-08-01

178

Organ doses to atomic bomb survivors during photofluorography, fluoroscopy and computer tomography  

International Nuclear Information System (INIS)

Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).

1991-01-01

179

Imaging Automation and Volume Tomographic Visualization at Texas Neutron Imaging Facility  

Energy Technology Data Exchange (ETDEWEB)

A thermal neutron imaging facility for real-time neutron radiography and computed tomography has been developed at the University of Texas reactor. The facility produced good-quality radiographs and two-dimensional tomograms. Further developments have been recently accomplished. A computer software has been developed to automate and expedite the data acquisition and reconstruction processes. Volume tomographic visualization using Interactive Data Language (IDL) software has been demonstrated and will be further developed. Volume tomography provides the additional flexibility of producing slices of the object using software and thus avoids redoing the measurements.

1999-11-14

180

Computed tomography of hilar cholangiocarcinoma: a new sign  

International Nuclear Information System (INIS)

Thirty-seven patients with histologic proof of cholangiocarcinoma at the confluence were examined by computed tomography (CT) to determine whether this examination is of value in the assessment of these patients for surgery and whether there are any features specific to this type of tumor. Thirty-two patients showed intrahepatic duct dilatation; six of these showed dilatation of ducts in one lobe only. Eighteen patients had intrahepatic low-attenuation areas, while eight had a mass lesion in the porta hepatis. The results of this study show that CT provides useful anatomic information preoperatively but that the appearances are nonspecific. Lobar atrophy is highly suggestive of hilar cholangiocarcinoma, either of long-standing or with unilateral portal venous involvement.

1986-04-14

181

Computed tomography in the evaluation of soft tissue tumors  

International Nuclear Information System (INIS)

In order to evaluate the role of Computed Tomography (CT) in prediction of nature, staging and follow-up of soft-tessue tumors, the authors examined by CT 124 patients with soft tissue neoplasms who later underwent surgery (116 cases) or fine needle biopsy (8 cases). Comparison between CT and surgical or anatomical results showed that CT was able to correctly predict the benignancy or malignancy of the masses in 76% of cases but it was very seldom able to allow an hystological prediction. On the contrary CT was found to be a very useful tool for pre-therapeutic staging and follow-up of the tumors, because it gave many diagnostic information which influenced therapeutic choiches and strategies.

1986-01-01

182

Computed tomography in the evaluation of 41 cases of Ewing's sarcoma  

International Nuclear Information System (INIS)

Computed tomography (CT) has already proved extremely effective both in cerebral and abdominal pathology. Several recent publications describing first heterogeneous series [1, 2, 7, 11-17], then studies of a single type of lesion [3-6, 8] have illustrated its usefulness in the study of bone lesions. This report deals with 41 cases of Ewing's sarcoma studied by CT at the Institut Gustave Roussy from October 1977 to July 1981, and tries to show both the limitations and indications of this technique for the diagnosis, treatment, and follow-up of Ewing's sarcoma as well as in the diagnosis of any eventual recurrence. (orig.).

183

Computed tomography in spinal osteoblastoma  

International Nuclear Information System (INIS)

In order to stress the role of computed tomography (CT) in the evaluation of benign spinal osteoblastoma, the authors examined by CT 10 patients with surgically and histologically proved osteoblastomas of the spine. Basing on surgical and histopathological findings CT proved to be a very important method for attesting the presence of the tumors (usually showed by radiographic examination), and specially for their staging and follow-up. CT in fact showed the real extent of the tumor into the spinal canal and towards the paraspinal soft tissues, and allowed the aerly detection of post surgical relapses. The authors conclude that CT is a primary diagnostic modality for preoperative planning and follow-up of benign osteoblastoma.

1986-01-01

184

Application of the neutron television fluoroscopic system to neutron computed tomography  

Energy Technology Data Exchange (ETDEWEB)

Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter. (orig.).

1984-10-01

185

Application of the neutron television fluoroscopic system to neutron computed tomography  

Energy Technology Data Exchange (ETDEWEB)

Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter.

1984-10-01

186

An application of the neutron television fluoroscopic system to neutron computed tomography  

International Nuclear Information System (INIS)

Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter. (orig.).

1984-10-01

187

High-Resolution Computed Tomography with Single-Slice Computed Tomography and 16-Channel Multidetector Computed Tomography: A Comparison Regarding Visibility and Motion Artifacts  

International Nuclear Information System (INIS)

Background: High-resolution computed tomography is the image procedure of choice in the evaluation of interstitial lung disease. Multidetector-row computed tomography provides the possibility of simultaneous reconstruction of thin and thick slices from the same raw data, acquired from one single series. Thus, it may be tempting to exclude the step-and-shoot series. Purpose: To compare high-resolution computed tomography (HRCT step-and-shoot) from single-slice CT (SSCT) and 16-channel multidetector CT (MDCT) in terms of visibility and motion artifacts, and to investigate whether thin images reconstructed from helical MDCT are equal to or better than conventional HRCT by SSCT in terms of visibility and motion artifacts. Material and Methods: 20 patients underwent HRCT step-and-shoot by SSCT (SSCT step-and-shoot) and MDCT (MDCT step-and-shoot), and a helical MDCT acquisition (MDCT helical). Images from four anatomical levels ...

2007-11-01

188

Consistency of ocular coherence tomography fast macular thickness mapping in diabetic diffuse macular edema  

Energy Technology Data Exchange (ETDEWEB)

Objectives: To investigate optical coherence tomography consistency on foveal thickness, foveal volume, and macular volume measurements in patients with and without diffuse diabetic macular edema. Introduction: Optical coherence tomography represents an objective technique that provides cross-sectional tomographs of retinal structure in vivo. However, it is expected that poor fixation ability, as seen in diabetic macular edema, could alter its results. Several authors have discussed the reproducibility of optical coherence tomography, but only a few have addressed the topic with respect to diabetic maculopathy. Methods: The study recruited diabetic patients without clinically evident retinopathy (control group) and with diffuse macular edema (case group). Only one eye of each patient was evaluated. Five consecutive fast macular scans were taken using Ocular Coherence Tomography 3; the 6 mm macular map ...

2007-07-01

189

The intrinsic nature of the Baldwin effect  

Science.gov (United States)

The relationship between the fluxes of the two strongest UV emission lines and flux in the continuum

1992-01-01

191

Phosphors for flat panel emissive displays  

Energy Technology Data Exchange (ETDEWEB)

An overview of emissive display technologies is presented. Display types briefly described include: cathode ray tubes (CRTs), field emission displays (FEDs), electroluminescent displays (ELDs), and plasma display panels (PDPs). The critical role of phosphors in further development of the latter three flat panel emissive display technologies is outlined. The need for stable, efficient red, green, and blue phosphors for RGB fall color displays is emphasized.

1995-07-01

192

Oxygen Implanted Materials  

International Science & Technology Center (ISTC)

Development of Oxygen Ion-Implanted Collector materials for Thermal Emission Converters of Thermal Energy into the Electric One.

193

Nitrogen emission sources; Kaellor till kvaeveutslaepp. Underlagsrapport  

Energy Technology Data Exchange (ETDEWEB)

In this report is described the sources to nitrogen emission and how the emission have changed over time. The cost and effect of the proposals given by the Swedish Environmental Protection Agency to cope with the emission of nitrogen to the sea is also treated. A separate chapter describes what we know today about phosphorus and eutrophication Basic document to report SNV--4735. 25 figs, 11 tabs

1997-06-01

194

Methodologies for estimating shipping emissions in the Netherlands. A documentation of currently used emission factors and related activity data  

Energy Technology Data Exchange (ETDEWEB)

Proper estimation of shipping emissions is essential for an impact assessment of shipping on air quality and health in port cities and coastal regions. In the Netherlands shipping is an important source of particulate matter. This report provides an internationally accessible and transparent summary and description of the methodologies used in the Netherlands Pollutant Release and Transfer Register (PRTR) to estimate PM emissions from shipping, including recently implemented updates.

2010-04-15

196

Infrared processes in the auroral zone  

International Nuclear Information System (INIS)

... aurorae carbon dioxide emission spectra infrared radiation nitrogen nitrogen

8432-01-01

199

Forest Carbon Projects: Avoided Deforestation (Hovani)  

Science.gov (United States)

... entitled: In-country Pilot Activities: Reducing Emissions from Deforestation and Degradation)...

200

Evolution of ultraviolet dwarfs  

Science.gov (United States)

UV dwarf star evolution, using central and gap star models emphasizing photoneutrino emission

1969-01-01

201

Energy intensity, CO{sub 2} emissions and the environmental Kuznets curve. The Spanish case  

Energy Technology Data Exchange (ETDEWEB)

This article analyses the role of energy intensity and the relationship between CO{sub 2} emissions and primary energy in order to explain the evolution of CO{sub 2} emissions by unit of real GDP. It also distinguishes two different meanings of CO{sub 2} emissions Kuznets curve hypothesis: the weak and the strong sense. It considers the case of Spain in the period 1972-1997 as an example in which there is not any evidence supporting this hypothesis in either sense. (author)

2001-06-01

202

Emissions from coal fired boilers and efforts to reduce them  

Energy Technology Data Exchange (ETDEWEB)

This paper reviews emission standards, technologies to control emissions, and the cost of these controls. It is concluded that international bodies will increasingly set minimum emissions, these standards will continue to be reduced, and in addition new substances will be controlled. The cost of this control will likely not exceed 0.5 cents per kWe-hr. 4 refs., 3 tabs.

1997-07-01

203

Economic effects on taxing CO{sub 2} emissions  

Energy Technology Data Exchange (ETDEWEB)

The CO{sub 2} emissions can be reduced by using economic instruments, like carbon tax. This project included two specific questions related to CO{sub 2} taxation. First one was the economic effects of increasing CO{sub 2} tax and decreasing other taxes. Second was the economic adjustment costs of reducing net emissions instead of gross emissions. A computable general equilibrium (CGE) model was used in this analysis. The study was taken place in Helsinki School of Economics

1996-12-31

205

Air pollutant emissions due to energy utilization in Turkey  

International Nuclear Information System (INIS)

Pollutant emissions due to fossil fuel and biomass energy utilization in Turkey have been estimated. Standard emission factors were used for estimating the levels of particulate matter, sulfur oxides, nitrogen oxides, carbon monoxide, volatile organic compounds, and aldehydes. The results are presented for different fuels and energy-consuming sectors for the reference year 1987. Total Turkish emissions vs energy consumption are presented for every fifth year since. 1960. (author).

206

Joint implementation for cost-effective carbon dioxide emission-reductions: An analysis of options in eastern Europe  

Energy Technology Data Exchange (ETDEWEB)

The costs of greenhouse gas emission-reductions vary among countries depending on emission levels, technologies used, past emission-reduction achievements, path of economic development, fuel mix, and initial endowment of hydrocarbon resources. The criterion of cost-effectiveness therefore suggests that the ways should be found to encourage emission reductions in the countries where the required costs of reduction of additional unit of emissions are the lowest. These countries usually face crucial capital constraints and have other development priorities than investing in reduction of greenhouse gas emissions. Developed countries could invest their resources in the former Soviet Union and the east European countries to achieve the same level of reduction of greenhouse gases with lower costs than they could in their own countries.

1996-12-31

207

Emissions trading and green power : profitability for buyers and sellers  

Energy Technology Data Exchange (ETDEWEB)

Proposed features of the competitive electricity market in Ontario were reviewed. The speaker predicted that demand for renewable energy in Ontario`s competitive electricity market will be affected by green power, emissions trading, labelling, and renewables portfolio standard. Under current regulations retailers can charge customers a premium for purchasing electricity generated by `green` sources. The existing limits on emissions of sulphur dioxide, nitrogen oxides and carbon dioxides will remain in place, but an emissions cap and trading program for all Ontario-based generation is an option to consider. Ontario`s Market Design Committee (MDC) has recommended the implementation of emissions trading for electricity-related air pollutants for all generators located in Ontario. The complex mechanics of emission trading are explained. The MDC recommendation of the use of standard ...

1998-12-31

208

National Emission Standards for Hazardous Air Pollutants submittal -- 1994  

Energy Technology Data Exchange (ETDEWEB)

This report focuses on air quality at the Nevada Test Site (NTS) for 1994. A general description of the effluent sources are presented. Each potential source of NTS emissions was characterized by one of the following: (1) by monitoring methods and procedures previously developed at NTS; (2) by a yearly radionuclide inventory of the source, assuming that volatile radionuclides are released to the environment; (3) by the measurement of tritiated water concentration in liquid effluents discharged to containment ponds and assuming all the effluent evaporates over the course of the year to become an air emission; or (4) by using a combination of environmental measurements and CAP88-PC to calculate emissions. Appendices A through J describe the methods used to determine the emissions from the sources. These National Emission Standards for Hazardous Air Pollutants (NESHAP) ...

1995-06-01

209

The relationships of carbon dioxide emissions and income in a newly industrialized economy  

British Library Electronic Table of Contents (United Kingdom)

This study investigates the carbon dioxide (CO2) emissions patterns in coordination with the economic development of Taiwan. The resulting quadratic relationship between emissions and income are partly due to the structural change of energy supply in Taiwan, with the introduction of nuclear energy in 1980 to 1986. This relationship is quite unique and different from the N-shaped relationships in some developed countries (de Bruyn and Opschoor, 1997; Friedl and Getzner, 2003). The CO2 emissions in Taiwan increase with the increasing imports of raw materials for economic activities and the increasing use of electricity. There is no evidence that the substantial increase of Taiwan's service sector contributed to slowing its CO2 emissions.

2012-01-01

210

Method for determining the concentration of atomic species in gases and solids  

Energy Technology Data Exchange (ETDEWEB)

Method for determining the concentration of atomic species in gases and solids. Measurement of at least two emission intensities from a species in a plasma containing the species after a sufficient time period has elapsed after the generation of the plasma and during a second time period, permits an instantaneous temperature to be established within the sample. The concentration of the atomic species to be determined is then derived from the known emission intensity of a predetermined concentration of that species in the sample at the measured temperature, a quantity which is measured prior to the determination of the unknown concentration, and the actual measured emission from the unknown species, or by this latter emission and the emission intensity of a species having known concentration within the sample.

1999-01-01

211

Pollutant Emission Factors from Residential Natural Gas Appliances: A Literature Review  

Energy Technology Data Exchange (ETDEWEB)

There is a need to reduce air pollutant emissions in some U.S. urban regions to meet federal and state air quality guidelines. Opportunities exist for reducing pollutant emissions from natural gas appliances in the residential sector. A cost-benefit analysis on various pollutant-reducing strategies is needed to evaluate these opportunities. The effectiveness of these pollutant-reducing strategies (e.g., low-emission burners, energy conservation) can then be ranked among themselves and compared with other pollutant-reducing strategies available for the region. A key step towards conducting a cost-benefit analysis is to collect information on pollutant emissions from existing residential natural gas appliances. An extensive literature search was conducted to collect data on residential natural-gas-appliance pollutant emission factors. The literature primarily describes laboratory ...

1996-08-01

212

Determination of anisotropic velocity model by reflection tomography of compression and shear modes; Determination de modele de vitesse anisotrope par tomographie de reflexion des modes de compression et de cisaillement  

Energy Technology Data Exchange (ETDEWEB)

As the jump from 2D to 3D, seismic exploration lives a new revolution with the use of converted PS waves. Indeed PS converted waves are proving their potential as a tool for imaging through gas; lithology discrimination; structural confirmation; and more. Nevertheless, processing converted shear data and in particular determining accurate P and S velocity models for depth imaging of these data is still a challenging problem, especially when the subsurface is anisotropic. To solve this velocity model determination problem we propose to use reflection travel time tomography. In a first step, we derive a new approximation of the exact phase velocity equation of the SV wave in anisotropic (TI) media. This new approximation is valid for non-weak anisotropy and is mathematically simpler to handle than the exact equation. Then, starting from an isotropic reflection tomography tool developed at Lt-'P, we extend the isotropic bending ray ...

2001-12-01

213

The Study of Phosphors Efficiency and Homogeneity using a Nuclear Microprobe  

Energy Technology Data Exchange (ETDEWEB)

Ion Beam Induced Luminescence (IBIL) and Ion Beam Induced Charge Collection (IBICC) have been applied in the study of the luminescence emission efficiency and investigation of the homogeneity of the luminescence emission in phosphors. The IBIL imaging was performed by using sharply focused ion beams or broad/partially-focused ion beams. The luminescence emission homogeneity in samples was examined to reveal possible distributed crystal-defects that may lead to the inhomogeneity of the luminescence emission in samples.The purpose of the study is to search for suitable luminescent thin films that have high homogeneity of luminescence emission, large IBIL efficiency under heavy ion excitation, and can be placed as a thin layer on the top of microelectronic devices to be analyzed with Ion Photon Emission Microscopy (IPEM). The emission yield was ...

2000-12-08

214

Consideration of the Change of Material Emission Signatures due to Longterm Emissions for Enhancing VOC Source Identification  

DEFF Research Database (Denmark)

The objectives of this study were to characterize the changes of VOC material emission profiles over time and develop a method to account for such changes in order to enhance a source identification technique that is based on the measurements of mixed air samples and the emission signatures of individual building materials determined by PTRMS. Source models, including powerlaw model, doubleexponential decay model and mechanistic diffusion model, were employed to track the change of individual material emission signatures by PTRMS over a ninemonth period. Samples of nine typical building materials were tested individually for nine months and later in combination to obtain actual mixture emissions. VOC emissions from each material were measured in a 50liter smallscale chamber. Chamber air was sampled by PTRMS over a 28day period to determine their emission rate ...

2011-01-01

215

Acid-deposition research program. Volume 2. Design of the emission inventory: emission inventory of sulfur oxides and nitrogen oxides in Alberta  

Energy Technology Data Exchange (ETDEWEB)

To predict air quality properly at a given location, it is necessary to identify all emission sources that will have significant impact at that location. Furthermore, the atmospheric pollutants that are emitted by these sources must be identified and quantitatively characterized. Once the air-quality predictions have been made, it is desirable to have some historical air-quality data for comparison. An efficient means of obtaining this information is through the use of detailed emission inventories and an inventory of air-quality-monitoring stations. Therefore, as part of the Alberta Government/Industry Acid Deposition Research Program (ADRP), three comprehensive inventories have been developed, namely: a sulfur dioxide (SO/sub 2/) emission inventory, a nitrogen oxides (NOx) emission inventory, and an inventory of air-quality-monitoring stations. Volume 2, Design of the Emission ...

1987-11-01

216

Road traffic exhaust gas emissions in Finland. LIISA 2001.1 calculation model; Suomen tieliikenteen pakokaasupaeaestoet. LIISA 95 -laskentajaerjestelmae  

Energy Technology Data Exchange (ETDEWEB)

This publication describes the modification of the road traffic exhaust emission calculation model LIISA and presents the new calculation results. The model has already established its position as the most important inventory tool for regional road traffic emissions in Finland. The LIISA model calculates road traffic emissions as a whole. The system comprises of three separate models: 1. a model for calculating automobile emissions for the years 2001-2021, 2. a model for calculating emissions backwards for the years 1980-2000, 3. a model for calculating the emissions of motorcycles and mopeds. All three parts have been modified. The LIISA model is one of the submodels of the comprehensive LIPASTO calculation system developed at VTT Building and Transport. The LIPASTO model is an inventory tool for emissions regarding all traffic modes in ...

2002-07-01

217

Practical implications of marine diesel engine emission regulations  

Energy Technology Data Exchange (ETDEWEB)

The main pollutants from marine diesel engines are oxides of nitrogen (NOx), sulfur oxides (SOx) and particulates (soot). However, the proposed marine diesel engine emission regulations will primarily focus on the levels of NOx and SOx. In the future, once the proposed regulations are met, the limits and levels of other emissions will come under increasing scrutiny, such as particulates, hydrocarbons and carbon monoxide. Regardless of the type of pollutant, there are generally two classes of emission control: (1) techniques that reduce the amount of pollutant formed in the combustion process, or (2) prevent the pollutants from reaching the atmosphere. Unfortunately, some of these control techniques will not be able to meet the incoming regulations. Therefore, this paper identifies the diesel engine emissions of concern, the impending regulations, and the merits of current and future ...

1996-09-01

218

Characterization and uncertainty analysis of VOCs emissions from industrial wastewater treatment plants  

British Library Electronic Table of Contents (United Kingdom)

Air toxics from the industrial wastewater treatment plants (IWTPs) impose serious health concerns on its surrounding residential neighborhoods. To address such health concerns, one of the key challenges is to quantify the air emissions from the IWTPs. The objective here is to characterize the air emissions from the IWTPs and quantify its associated uncertainty. An IWTP receiving the wastewaters from an airplane maintenance facility is used for illustration with focus on the quantification of air emissions for benzyl alcohol, phenol, methylene chloride, 2-butanone, and acetone. Two general fate models, i.e., WATER9 and TOXCHEM+V3.0 were used to model the IWTP and quantify the air emissions. Monte Carlo and Bootstrap simulation were used for uncertainty analysis. On average, air emissions fr...

2010-01-01

219

High resolution Computed Tomography in the study of temporal bone trauma  

International Nuclear Information System (INIS)

Thirty-five patients with temporal bone fractures were examined; the fractures were sometimes associated with dislocation of the assicular chain caused by road fatalities. Computed Tomography (CT) was performed either because of the presence of clinical symptoms associated with trauma of the temporal bone, because of a hemotympanum discovered during a CT scan of the brain. Thirty-three fractures were detected: 19 longitudinal, 6 transverse, and 8 complex. An incudostapedial dislocation was also detected, together with a displacement of a stapedial prosthesis from the lenticular process of incus, and 3 incus-malleus dislocation associated with fractures. High resolution CT allows the precise definition of the course of the fractures, of the associated dislocation of the ossicular chain, and of facial nerve lesion, thus allowing a more accurate surgical intervention. In the examination of the temporal bone, high resolution CT is preferible to pluridirectional ...

1988-01-01

220

Determination of the initial energy in computerized tomography with proton beams; Determinacao da energia inicial em tomografia computadorizada com feixe de protons  

Energy Technology Data Exchange (ETDEWEB)

In earliest works devoted to proton computed tomography it was shown that the advantage of pCT image reconstruction appears when the energy is close to the Bragg peak region, since the proton passes the object. This effect provided by the Bragg peak makes the computerized tomography with protons possible. However, when decreasing the initial proton energy, with the increase of the irradiation dose, there are two effects that work simultaneously in opposite ways. First, the energy loss of a proton in an object becomes bigger at small initial energy. At the same time decreasing of the proton energy results in the increase of the energy straggling, requiring a larger number of protons. In this work the radiation dose dependence on the proton initial energy was studied using analytical formulas and computer simulations. The investigation determined that the radiation dose practically does not depend on the initial energy, except in the energy ...

2007-07-01

221

Computed tomography of the thorax: a status report  

Energy Technology Data Exchange (ETDEWEB)

Computed tomography (CT) of the thorax shows early promise of important diagnostic advances. We believe that CT often provides information superior to that provided by standard roentgenographic techniques, is capable of significantly influencing patient management, and in selected instances, offers unique information not available by other methods. Computed tomography permits the imaging of mediastinal structures not possible with conventional roentgenographic methods and can diagnose with certainty benign mediastinal conditions such as pericardial cysts and focal or diffuse accumulations of fat. It is ideal for detecting pleural abnormalities and for displaying underlying parenchymal disease in patients with complex pleuroparenchymal shadows on conventional films. Pulmonary metastases unseen on the plain chest film can be detected with greater sensitivity than by any other method. Future applications of CT include the staging of mediastinal ...

1981-11-01

222

Computed tomography of the thorax: a status report  

International Nuclear Information System (INIS)

Computed tomography (CT) of the thorax shows early promise of important diagnostic advances. We believe that CT often provides information superior to that provided by standard roentgenographic techniques, is capable of significantly influencing patient management, and in selected instances, offers unique information not available by other methods. Computed tomography permits the imaging of mediastinal structures not possible with conventional roentgenographic methods and can diagnose with certainty benign mediastinal conditions such as pericardial cysts and focal or diffuse accumulations of fat. It is ideal for detecting pleural abnormalities and for displaying underlying parenchymal disease in patients with complex pleuroparenchymal shadows on conventional films. Pulmonary metastases unseen on the plain chest film can be detected with greater sensitivity than by any other method. Future applications of CT include the staging of mediastinal ...

223

Computed tomography of the orbit  

Energy Technology Data Exchange (ETDEWEB)

In less than a decade computed tomography (CT scanning) had a profound impact on diagnostic radiology. Radiology of the orbit is no exception. As early as 1973, reports published in the radiological literature indicated that this new noninvasive imaging method was a highly effective way of demonstrating intraorbital mass lesions. As CT scanners became widely available, computed tomography became a significant adjunct to ophthalmological diagnosis. Today the main indications for CT scanning of the orbit are: (1) suspected mass lesions, most frequently presenting as exophthalmos, (2) orbital trauma, including foreign bodies, (3) some congenital anomalies, and (4) suspicion of extension into the orbit of extraorbital disease processes. Along with ultrasonography, another new noninvasive imaging technique, CT has replaced a number of more invasive and often less effective diagnostic methods, such as orbital pneumography, venography, and ...

1981-01-01

224

Computed Tomography of the complications of prosthetic surgery of the abdominal aorta  

International Nuclear Information System (INIS)

Computerized Tomography has gained an important role in the diagnosis of the complications of prosthetic surgery of the abdominal aorta: the importance of such complications come from their frequency, which is proportional to the increasing number of interventions, and their severity. The authors investigated the CT patterns of the most frequent complications. 24 patients referred for strongly suspected postoperative complications were examined in 2 years: fever and leukocytosis (20 cases) and progressive anemia (4 cases) were the most frequent findings. The operation had been performed 7#+-# 12 weeks before (2 patients were excluded because surgery dated less than 3 weeks. 14 patients had infective complications: thickening (57%) and inhomogeneity (43%) of the periprosthetic wrap and ectopic gas bubble (78%) were the most frequent Computerized Tomography findings. The authors also observed 2 periprosthetic hematomas, 1 aneurysm relapse and 1 ...

1997-01-01

225

Clinical and tomographic aspects of macular microholes; Aspectos clinicos e tomograficos dos microburacos maculares  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To describe the clinical aspects and evaluate optical coherence tomography of macular microholes. Methods: Seven patients were assessed (8 eyes) with microholes of the macula. All patients underwent complete eye examination, fundus photography, fluorescent angiography and OCT-3 imaging. Results: Ages ranged from 26 to 69 years. Six patients were female (85.7%) and five of them had microhole in the right eye. The presenting symptom was decrease in visual acuity (71.3%) and central scotoma in (14.3%). Five eyes (71.4%) had no defects shown by fluorescent angiography. A defect in the outer retina was demonstrated in all eyes on optical coherence tomography. The lesions were nonprogressive. Conclusion: Macular microholes are small lamellar defects in the outer retina. The condition is nonprogressive, generally unilateral and compatible with good visual acuity. Fundus biomicroscopy associated with an optical coherence ...

2009-07-01

226

The European Dioxin Emission Inventory. Stage II. Final report  

Energy Technology Data Exchange (ETDEWEB)

For Stage II of the European Dioxin Project the following objectives were set: - Amendment of existing emission data collected for most relevant emission sources in order to reduce uncertainties of emission estimates. Collecting first emission data from countries not yet performing dioxin emission measurement programs. Extending the inventory of dioxin emissions to ambient air produced in Stage I by a complementary study on emissions to land and water. Extending the regional scope of data collection to countries in Central Europe. The report of Stage II of the European Dioxin Project is presented in 3 Volumes. Volume 1 contains an overview on the background and approach of different activities carried out and on the results obtained. These results are put into a broader view regarding the dioxin reduction measures in Europe leading to ...

2001-07-01

227

Use of surface affinity enrichment and cryo-embedding to prepare in vitro reconstituted mitotic chromosomes for EM tomography  

Energy Technology Data Exchange (ETDEWEB)

We present a novel preparation method for studies of in vitro reconstituted mitotic chromosomes from Xenopus laevis egg extracts. This method involves a gentle adsorption of chromosomes from the extracts using surface affinity enrichment, followed by plunge freezing, freeze-substitution and cryo-embedding before examination by EM tomography. For comparison, chromosomes were also prepared by a conventional method, which included immobilization of chromosomes in agarose and a room-temperature dehydration (embedding) protocol. Three-dimensional reconstructions showed that samples prepared with the new method have a greater interconnectivity of sub-structural features and a higher compaction ratio together with an apparently less perturbed chromatin structure than those prepared using the conventional approach. The implications of the new method for the preparation of other difficult samples and additional application possibilities are discussed.

2005-07-15

228

Three Dimensional Visualization for the Steam Injection into Water Pool using Electrical Resistance Tomography  

International Nuclear Information System (INIS)

The direct injection of steam into a water pool is a method of heat transfer used in many process industries. The amount of research in this area however is limited to the nuclear industry, with applications relating to reactor cooling systems. Electrical resistance tomography (ERT), a low cost, non-invasive and which has high temporal resolution characteristics, can be used as a visualization tool for the resistivity distribution for the steam injection into water pool such as IRWST. In this paper, three dimensional resistivity distribution of the process is obtained through ERT using iterative Gauss-Newton method. Numerical experiments are performed by assuming different resistive objects in the water pool. Numerical results show that ERT is successful in estimating the resistivity distribution for the injection of steam in the water pool

2010-10-01

229

Sialography, echography and computed tomography in parotid gland study  

International Nuclear Information System (INIS)

The diagnostic accuracy of sialography and ultrasonography (US) in the evaluation of parotid masses is evaluated. Furthermore the role of computed tomography (CT) in this pathology is discussed. In the personal experience US proved to be the best method in the recognition of a parotid tumor while sialography was superior in defining the intra or extraparotid site. The two investigations showed the same accuracy in the definition of benign or malignant nature of the mass. Therefore we consider US the only investigation in most istances; sialography could be performed when the site of the lesion is uncertain or an inflammatory lesion is suspected. CT is never the first investigation; its use is limited to a low number of cases, mainly for the evaluation of large masses and when the association US-sialography does not allow a sure diagnosis.

1985-01-01

230

Role of Computed Tomography in postoperative diskitis  

International Nuclear Information System (INIS)

Six patients with diskitis following lumbar disk surgery were investigated by Computed Tomography (CT). Four patients underwent CT in a rather early phase of the disease (5-37 days after the onset of the symptoms): a posterior paravertebral fluid collection was always recognized, while the plain film was normal. Later on (2-4 months), the classical signs of diskitis were evident, with both CT and the plain film. The collection was always present at CT. A reintervention, performed on 3 patients, revealed the purulent content of the collections. It seems reasonable to suggest a relationship between the collection and the subsequent diskitis; the collection is probably an early sign of the disease. Its detection is of grat value, because it could allow an immediate and adequate therapy. The authors stress the usefulness of performing CT in an early phase on this kind of symptomatic patients.

1988-01-01

231

Quantitative Computed Tomography (QCT) of vertebral spongiosa. Evaluation of a possible method for managment of postmenopausal osteoporosis (PMO)  

International Nuclear Information System (INIS)

A Quantitative Computed Tomography (QCT) method, simplifying the well-known technique proposed by Genant (1982) and applied to a standard third generation whole body CT scanner is described. This technique was applied in the measurement of the trabecular bone which has high sensitivity for metabolic changes. The BMC (Bone Mineral Content) measured in different groups of subjects (healthy postmenopausal patients versus women with postmenopausal osteoporosis) showed a highly significant difference (p<0.001). The precision of repositioning (coefficient of variation 1.8% to 2.3%, obtained in healty male patients) and the good, linear relationship computed from the phantom values, minimize measurement errors. Since this method is quickly applied and involves low-dose radiation-exposure, it could be introduced in the clinical study of metabolic bone diseases.

1987-01-01

232

Nondestructive techniques for the control of conditioned radioactive wastes  

International Nuclear Information System (INIS)

The final product of the radwaste conditioning process must satisfy certain requirments and physico-chemical properties in order to assure its safe long-term behaviour. Of course, the foreseen quality assurance and quality control should be conducted by means of non-destructive techniques. This work presents an over-view of various applicable non-destructive methods of analysis, showing their fields of investigation in testing waste packages, together with some arising practical problems. The most promising methods, such as eddy current testing, ultrasonic testing, #gamma#-scanning, #gamma#-spectroscopy, neutron counting and computerized tomography, are treated more deeply and some applications are presented. Particular attention is devoted to the development of a device based on computerized tomography; its essential components are reported and some design problems are also discussed.

2005-09-01

233

New thermal neutron imaging facility at the University of Texas reactor  

Energy Technology Data Exchange (ETDEWEB)

A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed at the University of Texas TRIGA reactor. Extensive Monte Carlo design calculations were used to determine optimal design parameters of the neutron collimator system to avoid costly trial and error. Thermal neutron flux determined by gold foil activation is 5 {times} 10{sup 6} n/cm{sup 2}{center_dot}s at the primary imaging location with beam size of 22.5 cm in diameter. The collimation ratio can be varied from 125 to 235. The neutron-to-gamma ratio is 7.8 {times} 10{sup 6} n/cm{sup 2}{center_dot}mR. The facility has been tested for radiography and tomography applications and is now fully operational.

1999-09-01

234

Neutron imaging system for neutron tomography, radiography, and beam diagnostics  

Energy Technology Data Exchange (ETDEWEB)

A neutron imaging system (NIS) has been recently installed at the University of Texas TRIGA reactor facility. The imaging system establishes new capabilities for beam diagnostics at the Texas Cold Neutron Source (TCNS) for real-time neutron radiography (RTNR) and for neutron computed tomography (NCT) research. The NIS will also be used for other research projects. The system consists of two subsystems as follows: (1) Thomson 9-in. neutron image intensifier (NII) tube sensitive to cold, thermal, and epithermal neutrons, (2) image-processing unit consisting of vidicon camera, two high-resolution monitors, image enhancement and measurement processor, and video printer. The NIS is installed at the cold neutron beam of the TCNS for testing and cold neutron beam diagnostics.

1995-12-31

235

Multidetector Computed Tomography in the Preoperative Workup of Hilar Cholangiocarcinoma  

International Nuclear Information System (INIS)

Hilar cholangiocarcinoma is associated with a dismal prognosis; however, curative resection may offer a chance of cure. Various factors should be considered in the surgical planning for curative resection. These factors include extent of bile duct involvement, relationship between portal vein and tumor involvement, diffuse hepato duodenal ligament infiltration, vascular invasion, lymph node metastasis, peritoneal seeding, and hepatic volume. Using high-quality volume data from multidetector-row computed tomography (MDCT) and adequate postprocessing images, radiologists can provide various types of information, imperative for curative resection of a hilar cholangiocarcinoma. This review illustrates the role of MDCT in the preoperative workup of hilar cholangiocarcinoma.

2009-10-01

236

Low-dose contrast protocol using the test bolus technique for 64-detector computed tomography coronary angiography  

British Library Electronic Table of Contents (United Kingdom)

Purpose We evaluated low-contrast injection protocols for coronary computed tomography angiography (CTA) using a 64-detector scanner and the test bolus technique. Materials and methods We randomly assigned 60 patients undergoing coronary CTA to one of two contrast material (CM) injection protocols. For the lowcontrast dose protocol (Plow), the patients received injections of iohexol-350 [0.7 ml/kg body weight (BW)] during 9 s, and the test-bolus technique was used. Under the conventional protocol (Pconv), they received iohexol-350 (1.0 ml/kg BW) during 15 s, and bolus tracking was used. We compared the protocols for attenuation values in the ascending aorta and coronary arteries and for the amount of CM required. Results There was no significant difference in the mean CT attenuation of the...

2011-01-01

237

Importance of preoperative imaging with 64-row three-dimensional multidetector computed tomography for safer video-assisted thoracic surgery in lung cancer  

British Library Electronic Table of Contents (United Kingdom)

Purpose Video-assisted thoracic surgery (VATS) has recently been adopted for complicated anatomical lung resections. During these thoracoscopic procedures, surgeons view the operative field on a two-dimensional (2-D) video monitor and cannot palpate the organ directly, thus frequently encountering anatomical difficulties. This study aimed to estimate the usefulness of preoperative three-dimensional (3-D) imaging of thoracic organs. Methods We compared the preoperative 64-row three-dimensional multidetector computed tomography (3DMDCT) findings of lung cancer-affected thoracic organs to the operative findings. Results In comparison to the operative findings, the branches of pulmonary arteries, veins, and bronchi were well defined in the 3D-MDCT images of 27 patients. Conclusion 3D-MDCT imag...

2009-01-01

238

Impact of diagnosis by enhanced multidetector-row computed tomography and magnetic resonance imaging for extrahepatic cholangiocarcinoma  

International Nuclear Information System (INIS)

Herein we present an impact of diagnosis by enhanced multidetector-row computed tomography and magnetic resonance imaging for extrahepatic cholangiocarcinoma (ECC). Although the diagnosis against the longitudinal stromal extension and surrounding tissue invasion of ECC by multi detector row CT (MDCT) and MRI was very strict, we could not detect any superficial mucosal spread (SMS). Furthermore, the diagnosis of lymphnode metastasis by MDCT/MRI was miserable. We believe that misdiagnosis of SMS is permissible since positive mucosal but not stromal surgical margin was not a significant factor influencing the postoperative prognosis. However, further advances in imaging diagnosis for ECC is needed. (author)

2009-10-01

239

Imaging automation and volume tomographic visualization at Texas Neutron Imaging Facility  

Energy Technology Data Exchange (ETDEWEB)

A thermal neutron imaging facility for real-time neutron radiography and computed tomography has been developed at the University of Texas reactor. The facility produced a good-quality radiographs and two-dimensional tomograms. Further developments have been recently accomplished. Further developments have been recently accomplished. A computer software has been developed to automate and expedite the data acquisition and reconstruction processes. Volume tomographic visualization using Interactive Data Language (IDL) software has been demonstrated and will be further developed. Volume tomography provides the additional flexibility of producing slices of the object using software and thus avoids redoing the measurements.

1999-07-01

240

High-Resolution Optical Coherence Tomography Findings in Solar Maculopathy and the Differential Diagnosis of Outer Retinal Holes  

British Library Electronic Table of Contents (United Kingdom)

PurposeTo characterize the morphology of outer retinal holes caused by solar maculopathy, using spectral-domain optical coherence tomography (SD-OCT). DesignThis study is an observational case series. MethodsThe SD-OCT findings of 3 patients (6 eyes) with chronic solar maculopathy are presented. ResultsSD-OCT demonstrates a characteristic appearance of partial-thickness hole(s) in the outer retina at the fovea. In 3 of 6 eyes, there is 1 hole directly beneath the umbo. In the remaining 3 eyes, there are multifocal holes spread across the fovea. Holes in more restricted layers, as had been previously reported with time-domain OCT, were not seen. In addition, advanced visualization of SD-OCT data demonstrates a hyperreflective ring around the outer retinal hole. ConclusionsSD-OCT can be used...

2011-01-01

241

Computed tomography colonography: the future of colon cancer screening  

Energy Technology Data Exchange (ETDEWEB)

Colorectal cancer (CRC) is the most common cause of cancer death among Canadian non-smokers. Each year about 21,500 Canadians are diagnosed with CRC. Ninety percent of cases occur in people aged 50 years or older. An estimated 4,800 Canadian men and 4,100 Canadian women die each year from the disease. About 75% of all new CRC cases arise in people with no known risk factors. Computed tomography colonography (CTC), a cross-sectional imaging examination that permits complete structural examination of the colon, shows promise as a tool for CRC screening. This article reviews the rationale for CRC screening, currently recommended Canadian and American screening guidelines and screening tools, and current evidence supporting CTC as a CRC screening tool and its advantages over conventional screening methods. (author)

2008-10-15

242

Computed tomography colonography: the future of colon cancer screening  

International Nuclear Information System (INIS)

Colorectal cancer (CRC) is the most common cause of cancer death among Canadian non-smokers. Each year about 21,500 Canadians are diagnosed with CRC. Ninety percent of cases occur in people aged 50 years or older. An estimated 4,800 Canadian men and 4,100 Canadian women die each year from the disease. About 75% of all new CRC cases arise in people with no known risk factors. Computed tomography colonography (CTC), a cross-sectional imaging examination that permits complete structural examination of the colon, shows promise as a tool for CRC screening. This article reviews the rationale for CRC screening, currently recommended Canadian and American screening guidelines and screening tools, and current evidence supporting CTC as a CRC screening tool and its advantages over conventional screening methods. (author)

2008-10-01

243

Computed Tomography of the spine in multiple myeloma  

International Nuclear Information System (INIS)

Computed Tomography (CT) of the spine was performed on 17 patients with myeloma in order to assess the role of the technique in recognizing and evaluating the extent of the lesions. Myelomatous lesions followed two patterns at CT: first of all, multiple focal lesions, whose density is either solid, liquid, or fatty; second, an extensive pattern involving the spongiosa of the vertebra, including the posterior arch. CT detected more lesions than conventional radiology; furthermore, the extent of the lesions was much better demonstrated by CT. CT should thus be performed: a) in case of pain and/or neurological findings in negative radiological examinations; b) to evaluate the extent of myelomatous lesions (mainly in the spine); c) in solitary myeloma CT may be performed on different bone segments with clinical symptomatology but normal X-ray findings.

1988-01-01

244

Characteristic features of intracranial meningiomas on magnetic resonance tomography  

International Nuclear Information System (INIS)

Twenty-three patients with intracranial meningiomas were examined by means of magnetic resonance tomography (MRT). In 13 patients the paramagnetic contrast medium gadolinium DTPA was used. Meningiomas show only slight changes in signal intensity compared with brain in the spin-echo mode, the greatest contrast being found on photon density images (TR 1600 ms, TE 35 ms). In T1 images more than 50% of the patients showed a low signal margin between tumour and brain. Hyperostosis of the calvarium is easily recognised, but MRT is unreliable for showing tumour calcification. After intravenous injection of gadolinium DTPA, there was marked homogeneous uptake in the meningiomas. These signs are useful for the diagnosis of a meningioma by MRT. (orig.).

245

Cardiac transplantation. Value of computed tomography  

International Nuclear Information System (INIS)

In 9 over 12 patients who underwent cardiac transplantation computed tomography was performed. In 5 of them CT was obtained also before the surgical treatment. In all patients angio-CT technique was performed, while the ECG-gated technique was employed only before surgery. CT shows changes in morphology of both atria but over all of the right one, and rotation of the heart on the longitudinal axis. The conditions of the pericardium are particulary well demonstrated: in 5 cases pericardial effusion was observed, 3 times localized and 2 times diffuse. Only in 1 patient a small thrombus in the right atrium was demonstrated. CT allows the possibility to obtain simultaneously information on mediastinum, lung and pleura. Pleural effusion, pulmonary infections and mediastinal complications are easily demonstrated.

1986-01-01

246

Biomechanical properties of the femoral neck relative to osteosynthesis methods and bone mineral content assessed by computed tomography  

International Nuclear Information System (INIS)

Bone mineral content as determined by computerized tomography (CT) and mechanical strength on axial loading were compared in 36 cadaveric femur specimens. Based on the CT measurements of density and area, the mass of a transverse slice of the femur was estimated. Highly significant correlations were demonstrated between strength and cancellous bone density. Even higher correlations were revealed when the bone masses of the proximal and distal femoral areas were calculated. Based on these findings, an equal distribution of the effective mass of the femur was postulated. This hypothesis was confirmed in an experimental rotational model. The CT attenuation values were also correlated to direct measurements of bone mineral content, i.e. calcium. Moreover, the strength of different metal implants, commonly used in femoral neck fractures, were assessed in cadaver specimens. 134 refs., 13 figs., 12 tabs.

247

Application of digital radiography to diagnosis of laryngeal diseases  

International Nuclear Information System (INIS)

Fuji Computed Radiography (FCR) is a new system of digital radiography that is based on the latest computer technologies. We applied this FCR system to the X-ray diagnosis of the laryngeal disease. Twenty patients with various laryngeal diseases were evaluated by both FCR frontal tomography and conventional screen-film frontal tomography under the same exposure condition. Both tomograms were then compared on the subject of the clarity of delineation of laryngeal structures. As the result, FCR tomograms revealed the feature of the laryngeal lumen and cartilages more clearly than conventional tomograms. In addition, energy subtraction method, which is one of FCR image processing systems, was presented as a new technical procedure to extinguish cervical spine shadows in plain anteroposterior laryngeal X-photograph. We stress that FCR system is the suitable procedure for X-ray analysis of laryngeal diseases, especially in the region related with ...

1986-01-01

248

An effective method to estimate multidimensional Gaussian states  

CERN Document Server

A simple and efficient method for characterization of multidimensional Gaussian states is suggested and experimentally demonstrated. Our scheme shows analogies with tomography of finite dimensional quantum states, with the covariance matrix playing the role of the density matrix and homodyne detection providing Stern-Gerlach-like projections. The major difference stems from a different character of relevant noises: while the statistics of Stern-Gerlach-like measurements is governed by binomial statistics, the detection of quadrature variances correspond to chi-square statistics. For Gaussian and near Gaussian states the suggested method provides, compared to standard tomography techniques, more stable and reliable reconstructions. In addition, by putting together reconstruction methods for Gaussian and arbitrary states, we obtain a tool to detect the non-Gaussian character of optical signals.

2009-01-01

249

Adenopathies in lung cancer: a comparison of pathology, Computed Tomography and endoscopic ultrasound findings  

International Nuclear Information System (INIS)

A prospective comparative study with pathology was performed to assess the clinical value of Computed Tomography (CT) and endoscopic ultrasound (EUS) for nodal staging in lung cancer. A total of 329 nodal stations were dissected or sampled and 755 lymph nodes were examined at histology. On a pre-station basis, CT had greater sensitivity (74%) than EUS (56%), but EUS was more specific (83% versus 93%). The accuracy rates of the two techniques were similar. In conclusion, endoscopic ultrasound should be part of a routine preoperative diagnostic approach to non-small-cell lung cancer., because of its high specificity. Results can be improved when EUS and CT are combined., which suggests that these imaging modalities should be used together in selected patients for the noninvasive staging of non-small-cell lung cancer to identify local lymphatic spread.

1999-01-01

250

A tomography system at the thermal neutron column of the ENEA Casaccia TRIGA reactor  

Energy Technology Data Exchange (ETDEWEB)

The developed system is intended for use at a collimated thermal neutron beam with a flux of about 10{sup 6} n/cm{sup 2} s. The system works with a cooled CCD array (192 x 165 pixels) and an intensifier for light from a NE426 scintillator with traditional optical coupling. A fine mechanical regulation system allows an accurate positioning of the tomographer, also ensuring the alignment of the CCD array with the rotation and translation axes. The acquisition of 200 projections is carried out in about 30 min with a reconstruction time (40 min max) depending on the reconstruction-matrix order. Radiography and tomography of significant objects are illustrated. The reconstruction algorithm, including spatial and temporal inhomogeneity corrections and filters, was tested with good results for projections up to 512 x 512 pixels. (orig.)

2002-07-01

251

A tomography system at the thermal neutron column of the ENEA Casaccia TRIGA reactor  

International Nuclear Information System (INIS)

The developed system is intended for use at a collimated thermal neutron beam with a flux of about 10"6 n/cm"2 s. The system works with a cooled CCD array (192 x 165 pixels) and an intensifier for light from a NE426 scintillator with traditional optical coupling. A fine mechanical regulation system allows an accurate positioning of the tomographer, also ensuring the alignment of the CCD array with the rotation and translation axes. The acquisition of 200 projections is carried out in about 30 min with a reconstruction time (40 min max) depending on the reconstruction-matrix order. Radiography and tomography of significant objects are illustrated. The reconstruction algorithm, including spatial and temporal inhomogeneity corrections and filters, was tested with good results for projections up to 512 x 512 pixels. (orig.)

252

A study of reconstruction algorithms and filters for an industrial X-ray tomography system  

Energy Technology Data Exchange (ETDEWEB)

Computed tomography (CT) has been incorporated in an industrial Diode-Array Digital Radiography (DADR) system. An input data size of 512 pixel points x 400 projections yielded a 400x400 output image matrix. Reconstruction algorithms used are the filtered backprojection (FBP) and the direct Fourier reconstruction (DFR). Various filters were used in the FBP reconstruction process and their effects on image quality were evaluated. A spatial resolution of 100 {mu}m was measured with a block of plates and a minimum detectable feature size in the range of 10-100 {mu}m was measured using thin wires. Industrial specimens imaged have included ceramic samples, ball bearings and integrated circuits. A number of engineering problems have been solved, such as adjustment of the X-ray source, centering of the rotator spindle in the view field and beam-hardening corrections. (orig.).

1990-12-20

253

Updated general technical guidelines for the environmentally sound management of wastes consisting of, containing or contaminated with persistent org  

Wastenet

Emissions and residues: Emissions may include, inter alia, nitrogen oxides, carbon monoxide, sulphur dioxide and other oxides

254

Understanding the nature of the statistics behind energy-related CO{sub 2} emissions  

Energy Technology Data Exchange (ETDEWEB)

Research reported here reveals that the reduction of CO{sub 2} emissions into the atmosphere, is mainly dependent on the decrease of the use of fossil fuels, but also on the development of environment-friendly technology and greening of the environment. 2 refs.

2001-07-01

255

Ultrasonic Acoustic Emissions from the Sapwood of Thuja occidentalis Measured inside a Pressure Bomb 1  

UK PubMed Central (United Kingdom)

An improved method of counting acoustic emission (AE) events from water-stressed stems of cedar (Thuja occidentalis L.) is presented. Amplified AEs are analyzed on a real time basis...Full Text Available

1984-04-01

256

Ultrasonic Acoustic Emissions from the Sapwood of Cedar and Hemlock 1  

UK PubMed Central (United Kingdom)

Measurements are reported of ultrasonic acoustic emissions (AEs) measured from sapwood samples of Thuja occidentalis L. and Tsuga canadensis (L.) Carr. during air dehydration....Full Text Available

1984-08-01

257

Thermal infrared spectra of surface rocks. Comparison of in the laboratory, in situ, and remote sensing data; Chihyo ganseki no netsusekigaiiki bunko tokusei. Chijo sokutei data to remote sensing data no hikaku  

Energy Technology Data Exchange (ETDEWEB)

An ASTER (advanced spaceborne thermal emission and reflection radiometer) is one of the image sensors. It is to be installed in an earth survey polar orbit platform satellite, EOS-AM1, which is to be launched in 1998, and it is going to start its operation. Data observed by the thermal infrared remote sensing of ASTER include the spectral emissivity, and the spectral emission reflectivity which is expressed by the function of temperature. It is required to overcome technical problems how to extract the spectral emissivity from the observed data. The spectral emissivity extracted from the remote sensing data by the MMD method, measured for samples collected in Cuprite area, Nevada, and/or measured at sampled points were compared to each other and discussed. The hemisphere spectral reflectivity, which is indirect spectral emissivity, agreed well with the direct ...

1996-10-01

258

Performance and Emission Characteristics of Diesel Engine Fueled with Ethanol-Diesel Blends in Different Altitude Regions  

UK PubMed Central (United Kingdom)

In order to investigate the effects ethanol-diesel blends and altitude on the performance and emissions of diesel engine, the comparative experiments were carried out on the bench of turbo-charged diesel...Full Text Available

2011-01-01

259

Mortality among members of a heavy construction equipment operators union with potential exposure to diesel exhaust emissions.  

UK PubMed Central (United Kingdom)

A historical prospective mortality study was conducted on a cohort of 34 156 male members of a heavy construction equipment operators union with potential exposure to diesel exhaust emissions. This...Full Text Available

1985-07-01

260

Meeting future exhaust emissions standards using natural gas as a vehicle fuel: Lessons learned from the natural gas vehicle challenge `92  

Energy Technology Data Exchange (ETDEWEB)

The Natural Gas Vehicle Challenge `92, organized by Argonne National Laboratory and sponsored by the US Department of Energy, the Energy, Mines, and Resources - Canada, the Society of Automotive Engineers, and many others, resulted in 20 varied approaches to the conversion of a gasoline-fueled, spark-ignited, internal combustion engine to dedicated natural gas use. Starting with a GMC Sierra 2500 pickup truck, donated by General Motors, teams of college and university student engineers strived to optimize Chevrolet V-8 engines operating on natural gas for improved emissions, fuel economy, performance, and advanced design features. This paper focuses on the results of the emission event, and compares engine mechanical configurations, engine management systems, catalyst configurations and locations, and approaches to fuel control and the relationship of these parameters to engine-out and tailpipe emissions of regulated ...

1992-09-01

261

Measuring characteristics on emissivity using infrared thermometer for RCCS  

International Nuclear Information System (INIS)

In VHTGR (Very High Temperature Gas-cooled Reactor), the radiation plays an important role in heat transfer through the cavity in RCCS (Reactor Cavity Cooling System). We performed the series of experiments to measure the emissivity using the infrared thermometer with wavelength range of 8#approx#14 #mu#m. As the first step, the transmittance of Zinc Selenide (ZnSe) window was measured to estimate the emissivity that can compensate the attenuation effect of window. The kind of gas with various concentrations in the cavity will be released during postulated accidents to the coolant type, so it is essential to estimate the effects of gas on the measurement of emissivity. In this manner we measured the emissivity with the air, the helium and the steam inside chamber. The results represent that the concentration of the air and the helium do not affect the emissivity significantly while ...

2004-12-01

262

Inhibited spontaneous emission by a Rydberg atom  

Science.gov (United States)

Spontaneous radiation by an atom in a Rydberg state is inhibited by use of parallel conducting planes to eliminate the vacuum modes at the transition frequency. Spontaneous radiation emission is observed to turn off abruptly at the cutoff frequency of the waveguidelike structure, and the natural lifetime is measured to increase by a factor of at least 20.

1985-11-11

263

Industrial emissions cause extreme urban ozone diurnal variability  

UK PubMed Central (United Kingdom)

Simulations with a regional chemical transport model show that anthropogenic emissions of volatile organic compounds and nitrogen oxides (NOx = NO + NO2) lead to a dramatic diurnal...Full Text Available

2004-04-27

264

Global emission trends  

Energy Technology Data Exchange (ETDEWEB)

Emissions of sulphur and nitrogen oxides are continuing to fall in Europe but rise in Asia, according to calculations based on individual countries' predictions of economic development. The upward trend is slower than in previous predictions. 2 refs., 2 figs., 2 tabs.

2005-06-01

265

FT-IR spectroscopic studies of polycyclic aromatic hydrocarbons  

International Nuclear Information System (INIS)

Proper assessment of the hypothesis which correlates polycyclic aromatic hydrocarbons (PAHs) with the unidentified infrared emission bands requires additional experimental laboratory data. In order to address this need, thermal infrared emission studies were performed on a subset of PAHs suggested to be of astrophysical importance. It was proposed that infrared emission from interstellar PAHs occurs following absorption of an ultraviolet photon. Since energy transfer to the ground electronic state can be rapid for a species in which intersystem crossing is negligible, the emission spectrum may be viewed as resulting from an equilibrium vibrational temperature (Leger and d'Hendecourt, 1987). This has been the basis for using infrared absorption spectra to calculate the corresponding emission spectra at various temperatures. These calculations were made using room temperature infrared ...

1990-04-01

266

Ecological relevance of air pollution abatement measures as a decision aid  

Energy Technology Data Exchange (ETDEWEB)

Air pollution abatement measures are not an end in themselves, and undesirable side effects should be taken into account. The proposed emission index takes into account the total emissions caused by a technical project as well as the effects of the individual pollutants.

1983-01-01

267

Bioavailability and biotransformation of the mutagenic component of particulate emissions present in motor exhaust samples.  

UK PubMed Central (United Kingdom)

The pharmacokinetic concepts of bioavailability and biotransformation are introduced into the assessment of public health risk from experimental data concerning the emissions of potentially mutagenic...Full Text Available

1983-01-01

268

Benchmarking of refinery emissions performance : Executive summary  

International Nuclear Information System (INIS)

This study was undertaken to collect emissions performance data for Canadian and comparable American refineries. The objective was to examine parameters that affect refinery air emissions performance and develop methods or correlations to normalize emissions performance. Another objective was to correlate and compare the performance of Canadian refineries to comparable American refineries. For the purpose of this study, benchmarking involved the determination of levels of emission performance that are being achieved for generic groups of facilities. A total of 20 facilities were included in the benchmarking analysis, and 74 American refinery emission correlations were developed. The recommended benchmarks, and the application of those correlations for comparison between Canadian and American refinery performance, were discussed. The benchmarks were: sulfur oxides, nitrogen oxides, ...

2003-01-01

269

Particle emission in hydrodynamics: a problem needing a solution  

CERN Document Server

A survey of various mechanisms for particle emission in hydrodynamics is presented. First, in the case of sudden freeze out, the problem of negative contributions in the Cooper-Frye formula and ways out are presented. Then the separate chemical and thermal freeze out scenario is described and the necessity of its inclusion in a hydrodynamical code is discussed. Finally, we show how to formulate continuous particle emission in hydrodynamics and discuss extensively its consistency with data. We point out in various cases that the interpretation of data is quite influenced by the choice of the particle emission mechanism.

2004-01-01

270

Natural gas - to keep the air clean  

Energy Technology Data Exchange (ETDEWEB)

The production of and emission factors for the air-polluting matters sulfur dioxide, nitrogen oxides, carbon monoxide, hydrocarbons (esp. benz(a)pyrene), aldehyde and soot with regard to natural gas, excluding process furnaces, are dealt with. The comparison with other fuels indicates that only as to nitrogen oxides and carbon monoxide are emission factors equal in order of magnitude. As a summary measure of all air-polluting matters the emission index as proposed already in 1972 is applied. It shows emissions with single-room furnaces for heating oil EL to be six times as high as with natural gas; with black-coal briquettes the factor is at least 33, with wood chimneys about 200.

1983-02-01

271

Flue gas desulphurization and nitrogen oxide emission reduction status in the Federal Republic of Germany  

International Nuclear Information System (INIS)

The Federal Republic of German (FRG) had uniquely strict emission legislation for particulates SO_2 and NO_X from fossil-fired power plants. The 13th Regulation to the Federal Emission Control Act required that by 1 July 1988 all large furnaces fired with solid or liquid fuels that would not be decommissioned by 1993 be retrofitted with SO_2 control technology. The emission limits are 15 per cent of the sulphur introduced with the fuel (400 mg/m"3 maximum) at thermal capacities above 300 MW. 1 ref., 9 figs, 15 bibliographies.

1991-12-01

272

Emission of light charged particles accompanying uranium fission induced by 153-MeV protons  

Energy Technology Data Exchange (ETDEWEB)

The emission of light charged particles from heavy fragments of uranium fission induced by 153-MeV protons is studied. The probability of their emission is 2.7 x 10{sup - 2} per fission event. It is found that these particles affect the distribution of angles of fragment divergence and the angular distribution of heavy fragments with respect to the primary-proton beam. Experimental results suggest that the preequilibrium emission of particles is correlated with fission. Two mechanisms of interaction between 153-MeV protons and uranium nuclei are considered. 13 refs., 10 figs., 1 tab.

1995-12-01

273

Economic Evaluation of Carbon Dioxide and Nitrous Oxide Emission Reducti\\\\\\rons in Industry in the EU  

Wastenet

However, these intra-industrial structural changes are not considered in this bottom-up study.

274

A study on an electronically controlled liquefied petroleum gas diesel dual-fuel automobile  

Energy Technology Data Exchange (ETDEWEB)

In this paper, the control scheme of a liquefied petroleum gas (LPG)-diesel dual-fuel engine with electronic control is illustrated, the external characteristics and load characteristics of the LPG-diesel dual-fuel engine and the diesel engine are compared and analysed, and the results of automobile road tests are also given. The experimental results show that, compared with diesel, the output performance of dual fuel is not reduced, while smoke emission of dual fuel is significantly reduced, NO{sub x} emission of dual fuel is hardly changed, but HC emission and CO emission of dual fuel are increased and fuel consumption of dual fuel is reduced. (Author)

2005-02-15

276

The possible impact of atmospheric radioactive discharges from UK nuclear installations on acid deposition  

International Nuclear Information System (INIS)

The effect of atmospheric radioactive emissions from United Kingdom nuclear installations on acid deposition is assessed. Nitrogen oxide and ozone production resulting from and associated with discharges of airborne radioactivity, comparison with conventional emissions, and the direct effects of radioactive emissions on trees, are all discussed. (UK).

277

The development and testing of emissivity enhancement coatings for thermophotovoltaic (TPV) radiator applications  

Energy Technology Data Exchange (ETDEWEB)

One requirement of a thermophotovoltaic (TPV) radiator is to efficiently emit photons at high temperatures to TPV cells for conversion to electric power. Because many candidate radiator materials with adequate structural properties display low emissivity, coatings or other surface modifications are required for enhancement of emissivity. Six plasma sprayed coatings and one textured surface demonstrated adequate thermal stability and emittance values of 0.8 or greater. Promising attributes of modified surfaces are identified.

1999-03-01

278

Soils and greenhouse gases: management for mitigation  

Energy Technology Data Exchange (ETDEWEB)

This article, with 25 references, reviews the soil sources and sinks of carbon dioxide, methane, and nitrous oxide. The mitigation of greenhouse gas releases is discussed covering reduction of carbon dioxide emissions by a change in land use, the use of alternative waste disposal methods such as composting or recycling to reduce methane emissions, and management of nitrogen fertiliser applications to reduce nitrous oxide emissions. (Author)

1995-08-21

279

National and international options for Switzerland to curb CO{sub 2} emissions  

Energy Technology Data Exchange (ETDEWEB)

Designing efficient policies for curbing greenhouse gas (GHG) emissions is of particular interest for todays policy makers, in view of global climate change threats. This paper analyses the options Switzerland has for curbing its CO{sub 2} emissions. Using MARKAL and MARKAL-NACRO models, it investigates, in particular effects of national and international carbon taxes. (author) 3 figs., 1 tab., 6 refs.

1996-06-01

280

National Dioxin Study Tier 4 - Combustion Sources: Final Test Report - Site 10, Secondary Copper Recovery Cupola Furnace MET-A,  

Science.gov (United States)

The report summarizes the results of a dioxin/furan emissions test of a secondary copper recovery cupola furnace equipped with an afterburner for hydrocarbon emissions control and two baghouses for particulate emissions control. The cupola furnace is used...

1987-01-01

281

Greenhouse gas emissions from the international maritime transport of New Zealand's imports and exports  

International Nuclear Information System (INIS)

Greenhouse gas emissions from international maritime transport are exempt from liabilities under the Kyoto Protocol. Research into quantifying these emissions is ongoing, and influences policy proposals to reduce emissions. This paper presents a cargo-based analysis of fuel consumption and greenhouse gas emissions from New Zealand's international maritime transport of goods. Maritime transport moves 99.5% (by mass) of New Zealand's internationally traded products. It is estimated that 73% of visiting vessels' activity can be directly attributed to the movement of goods in and out of New Zealand. A cargo-based methodology was used to estimate that the international maritime transport of New Zealand's imports and exports consumed 2.5 million tonnes (Mt; 2.6 billion litres) of fuel during the year 2007, which generated 7.7 Mt of carbon dioxide (CO_2) emissions. Double-counting of ...

2011-03-01

282

GHG-emissions for cars with different power trains over the whole life cycle  

Energy Technology Data Exchange (ETDEWEB)

The method of life-cycle assessment (LCA) has been applied to cars with different power trains. As an example, the results for greenhouse gas (GHG) emissions are presented. They show possibilities and limits for the reduction of these emissions in the transportation sector by means of advanced technology. (author) 2 figs., 4 refs.

1999-08-01

283

Emissions to air in Sweden: sulphur dioxide, nitrogen oxides, carbon dioxide, methane, nitrous oxide, carbon monoxide and volatile organic compounds, 1999  

International Nuclear Information System (INIS)

The method for calculating emissions to air has been revised, which has led to adjustments. Because of this, emissions in 1999 cannot yet be compared with previous years. Emissions in 1990 - 1998 are being recalculated now using the new method and are expected to be ready during 2001. Emissions to air of carbon dioxide (CO_2) in Sweden was 56.58 million tonnes in 1999, not including emissions from biofuels and international bunkers. The major sources of CO_2 emissions are the combustion of fossil fuels and the use of fuels for mobile sources. Total emissions to air of sulphur dioxide (SO_2) and nitrogen oxides (NO_x, counted as NO_2) in Sweden was 66 000 and 263 000 tonnes respectively in 1999. International bunkers are not included. The major source of SO_2 emissions is combustion of fossil fuels. Road traffic is the ...

2000-11-01

284

Emission-Line versus Continuum Correlations in Active Galactic Nuclei  

CERN Document Server

The Baldwin Effect, a negative correlation between emission-line equivalent width and luminosity in active galactic nuclei, is still of interest as a diagnostic of accretion physics nearly thirty years after its discovery. This review examines recent developments in the study of correlations between line and continuum emission in AGNs, as measured both in ensembles and in individual sources.

2006-01-01

285

Role of CT in TNM staging of laryngeal and hypopharyngeal tumors  

International Nuclear Information System (INIS)

70 patients with squamouscell carcinoma of larynx and hypopharynx were examined by computed tomography; the TNM staging of tumors by CT, by endoscopy and by surgical operation was reviewed. CT proved to be reliable both to recognize the presence of neoplasms, with the exception of those very superficial, and their deep spreading to preepiglottic and paralaryngeal spaces, to the soft tissues of the neck and to the cartilages. Therefore CT is the examination of choice in laryngeal neoplasms staging, because it precisely completes the clinical and endoscopical informations.

1986-01-01

286

Right-sided invasive metastatic thymoma of the heart  

British Library Electronic Table of Contents (United Kingdom)

Cardiac tumours may display diverse symptoms through potential involvement of any structure of the heart. We describe a case of a highly malignant thymoma with involvement of different cardiac structures with important haemodynamic compromise. With the high sensitivity of transthoracic echocardiography for detection of intracardiac masses, computed tomography and magnetic resonance add essential structural preoperative information on the tumour and surrounding tissue as vessels, pleura, lung and mediastinum.

2011-01-01

287

New concept to optimize emergency diagnoses in patients with multiple injuries  

International Nuclear Information System (INIS)

To optimize the emergency care of patients with multiple injuries, a special emergency room with integrated radiological equipment has been developed. It consists of a linear array of a computed tomography system, a mobile C-arm with an integrated scattered radiation grid for conventional films and a C-arm fluorographic system. The intent is to avoid delay caused by transport and repositioning of the patient. It enables all necessary diagnostic procedures to be performed within a minimal amount of time. (orig./MG).

288

Monte Carlo design calculations for a neutron imaging facility collimator  

Energy Technology Data Exchange (ETDEWEB)

A thermal neutron imaging facility for computed tomography and real-time neutron radiography is being developed at the University of Texas at Austin. The TRIGA reactor is a graphite-reflected Mark It pool-type research reactor. The neutron imaging facility will use beam port, which is at one end of a through part. Monte Carlo calculations were used to design the neutron collimator for this facility.

1996-12-31

289

Kinetic estimation of infused Lipiodol within hepatoma using CT dynamic study  

Energy Technology Data Exchange (ETDEWEB)

Distribution of Lipiodol within hepatic tumor was evaluated using serial computed tomography. Imagistic Lipiodol transition into the tumor via hepatic artery was slower than that of water soluble contrast medium, spreading to central part first and turn to peripheral part of the tumor. This method was thought to be useful to clarify Lipiodol distribution in hepatic tumor and to decide the method or necessity of additional trans-arterial therapy. (author).

1991-02-01

290

Computed tomography of the urinary bladder. Clinical application of the olive oil-filled method  

Energy Technology Data Exchange (ETDEWEB)

Out of one hundred cases of the urinary bladder abnormalities examined by this method, CT staging and pathological correlations were investigated in 61 cases of the urinary bladder neoplasms. Accuracy of CT staging was 87% in this series with possible exception of 6 cases involving the bladder base and dome. CT scan using this method is the most reliable procedure to determine the treatment modalities of the urinary bladder tumors.

1982-01-01

291

Computed tomography of the chest: A teaching file  

Energy Technology Data Exchange (ETDEWEB)

As a self-teaching tool, this illustrated guide facilitates home study of the complexities of thoracic CT's. Over 400 illustrations and accompanying copy are used to provide a basis for understanding the CT appearances of disease processes and a comparison of CT lookalikes. It updates new and interesting developments in the format of case presentations.

1987-01-01

292

Computed tomography of intrahepatic cholangiocarcinoma  

International Nuclear Information System (INIS)

Intrahepatic cholangiocarcinoma is an uncommon tumor as primary hepatic neoplasm. Five cases of cholangiocarcinoma, mass forming peripheral type, are reported about its CT findings. They were manifested as a poorly marginated low density mass with a irregular stellate area. In one case, a cut section of the gross specimen following surgery showed a central callagenous scar and vessels within the necrotic tumor. (author).

293

Complete Dissection of a Hepatic Segment after Blunt Abdominal Injury Successfully Treated by Anatomical Hepatic Lobectomy: Report of a Case  

UK PubMed Central (United Kingdom)

A 21-year-old male patient was transferred to the emergency room of our hospital after suffering seat belt abdominal injury in a traffic accident. Abdominal computed tomography revealed a massive hematoma...Full Text Available

294

Clinical helical tomotherapy commissioning dosimetry  

International Nuclear Information System (INIS)

Helical tomotherapy presented many unique dosimetric challenges and solutions during the initial commissioning process, and some of them are presented. The dose calculation algorithm is convolution/superposition based. This requires that the energy fluence spectrum and magnitude be quantified. The methodology for doing so is described. Aspects of the energy fluence characterization that are unique to tomotherapy are highlighted. Many beam characteristics can be measured automatically by an included megavoltage computed tomography imaging system. This greatly improves data collection efficiency.

2003-12-01

295

CT scan findings in cerebral paragonimiasis  

International Nuclear Information System (INIS)

Computed tomography was performed on 5 patients with chronic cerebral paragonimiasis. CT showed solitary or multiple, amorphous, round, or oval calcifications, and ventricular enlargement in all 5 cases. A large low-density area is also found in 4 of the 5 cases. These CT findings are compatible with previously reported findings of simple X-ray films of the skull, pneumoencephalography, and pathological studies. (author).

1982-01-01

296

CT imaging of a primary malignant mixed mullerian tumor arising from the peritoneum  

British Library Electronic Table of Contents (United Kingdom)

Primary peritoneal malignant mixed mullerian tumors are very rare. We report the case of a patient presenting with pain in the right upper quadrant of the abdomen and in whom the physical examination demonstrated a peritoneal mass. Computed tomography (CT) confirmed the presence of a mass, with invasion of adjacent organs.

2008-01-01

297

Bilateral enlargement of the orbital muscles: first manifestation of renal adenocarcinoma; Espessamento da musculatura extrinseca orbitaria bilateralmente: manifestacao primaria de adenocarcinoma renal  

Energy Technology Data Exchange (ETDEWEB)

The authors present an unusual case of a patient with orbital metastases from renal carcinoma involving the extra ocular muscles bilaterally. The importance of computed tomography for the differential diagnosis with other orbital lesions is emphasized. (author)

2000-06-01

298

UK Greenhouse Gas Emission Inventory, 1990 to 1993. Annual report for submission under the framework convention on climate change  

Energy Technology Data Exchange (ETDEWEB)

This report presents estimates of the annual anthropogenic UK emissions of greenhouse gases for the years 1990-93 for submission under the Framework Convention on Climate Change. The gases considered are carbon dioxide, methane, nitrous oxide, nitrogen oxides, carbon monoxide and non-methane volatile organic compounds. Emissions of all the gases have declined since 1990. In particular, those of carbon dioxide have fallen by 4%; those of methane by 8% and those of nitrous oxide by 28%. Emission estimates are reported in the IPCC Standard Tables format disaggregated by source category and fuel. The methodology used for the estimates and how they relate to the UK National Atmospheric Emissions Inventory is discussed in an appendix. (author)

1995-10-01

299

Toward finding an optimal stockpile geometry to reduce dust emissions  

Energy Technology Data Exchange (ETDEWEB)

Fugitive dust emissions from stockpiles in the open storage yards of industrial zones and the subsequent atmospheric dust dispersion have brought about many ecological and economical problems. This paper introduces a new approach to reduce pollutant emissions by simply changing pile configuration and without affecting the operational activity on these parks. Flow around piles of different geometries and for various wind conditions was studied using previously validated Computational Fluid Dynamic (CFD) simulations. Different pile height scenarios were investigated corresponding to a constant material volume and a fixed angle of repose under various wind magnitudes. The results obtained were integrated in order to evaluate the rate of dust emissions for the various configurations considered. It was found that, for the range of wind conditions and pile dimensions tested, an optimal geometry exists which corresponds to the ...

2006-07-01

300

Problematic of atmospheric pollution in Lebanon: the better stake is apprehended, the best acts are taken  

International Nuclear Information System (INIS)

The document presents an overview on atmospheric pollution in Lebanon, with an analysis of sources of pollution, their impact on local and global environment and their control.Local causes of pollution are mainly: -Thermal power plants of electric power production which produce 75% SO_2 emission and 60% dust - Industries, especially cement industry - Land transportation which produces 70% NOX emission and 50% CO_2 A description of air pollution caused by these three sectors is revealed. Pollutants derived from fuel combustion are analyzed. It is estimated that in 2010, Co_2 emission will reach 5204450 tons, SO_2 emission will be 136470 tons, NOX emissions 96870 and dust estimated to 4130 tons. CFC consumption and measures of control according to Montreal Protocol are described. Recommendations for control of air pollution in Lebanon within a national policy are presented.

301

Natural gas and quality of fuels for the reduction of atmospheric pollution  

International Nuclear Information System (INIS)

The production of atmospheric pollutants in combustion processes depends on plant characteristic, combustion conditions and fuel quality. The influence of fuel quality on the emission of sulphur oxides, nitrogen oxides, carbon monoxide, dust and carbon dioxide and on the emission of some toxic pollutants, such as heavy metals and polycyclic aromatic hydrocarbons, is analysed. The comparison between the emission limits, fixed by the Italian legislation, and the uncontrolled pollutant emissions, produced by fossil fuel combustion in power plants and industrial use, shows that, in order to comply with the limits, a reduction of pollutant emissions is required through the use of abatement systems and cleaner fuels where natural gas has a primary role. The use of cleaner fuels is particularly required in heating plants and appliances for the residential sector, where the development of ...

1998-01-01

302

Low emission fuel engine and method of operating same  

Energy Technology Data Exchange (ETDEWEB)

This patent describes a low emission duel fuel engine system. It comprises: a dual fuel engine having a combustion chamber; a fuel oil supply connected to the engine; a fuel gas supply connected to the engine; and means connected between the fuel oil supply and the engine for injecting fuel oil into the engine. The means connected between the engine and fuel oil supply limiting the injection of fuel oil to the combustion chamber to pilot ignition quantities only, wherein the limiting means includes means for limiting the injection of fuel oil such that the exhaust emission of NO{sub x} is at an emission rate of less than 1 GM/PH-HR, whereby the exhaust emission performance of the dual fuel engine is enhanced.

1990-09-11

303

Formaldehyde surface-emission monitor. Protocol I: pressed-wood products  

Energy Technology Data Exchange (ETDEWEB)

The formaldehyde surface emission monitor (FSEM) has been developed for passive non-destructive measurement of formaldehyde (CH/sub 2/O) emission rates from CH/sub 2/O resin-containing materials. It is envisaged as a potential quality control and in-situ monitoring technique. For quality control applications to pressed-wood products, strong correlations between the results of the FSEM and environmentally controlled (small scale) chamber tests were observed. The FSEM is used to measure the cumulative CH/sub 2/O emission from a finite area of pressed-wood product during a fixed test period. The final result is reported as an average CH/sub 2/O emission rate (mg CH/sub 2/O/m/sup 2/h).

1983-06-01

304

Emissions and efficiency from production cooktop burners firing natural gas  

Energy Technology Data Exchange (ETDEWEB)

Investigations were conducted on the range of emission rates of NO, NO[sub 2], CO and hydrocarbons, and the thermal efficiencies produced by each burner on three production cookers, supplied by different Australian manufacturers. It was found that the emissions and efficiencies were markedly affected by (1) the thermal input, both with and without a load on the burner, and (2) the load-height to flame-length ratio, with a load on the burner. The effect of hydrocarbon leakage into the secondary/dilution air was investigated, to explain the observed correlation of hydrocarbon emission rate with dilution air flow. The hydrocarbons were found to arise from two sources: -leakage from the stabilisation ports at the base of the burner, which was found to be significant at the higher thermal input; -incomplete combustion of the fuel in the premix, which was the dominant source of hydrocarbons emissions at the ...

1994-12-01

305

Radionuclide air emissions report for the Hanford Site -- calendar year 1997  

Energy Technology Data Exchange (ETDEWEB)

This report documents radionuclide air emission from the Hanford Site in 1997, and the resulting effective dose equivalent to the maximally exposed member of the public, referred to as the MEI. The report has been prepared in accordance with reporting requirements in the Code of Federal Regulations, Title 40, Protection of the Environment, Part 61, National Emissions Standards for Hazardous Air Pollutants, Subpart H, National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities. This report has also been prepared in accordance with the reporting requirements of the Washington Administrative Code Chapter 246-247, Radiation Protection-Air Emissions. The effective dose equivalent to the MEI from the Hanford Site`s 1997 point source emissions was 1.2 E-03 mrem (1.2 E-05 mSv), which is well below the 40 CFR 61 ...

1998-06-17

306

Unification of Luminous Type 1 Quasars through CIV Emission  

CERN Document Server

Using a sample of 30,000 quasars from SDSS-DR7, we explore the range of properties exhibited by high-ionization, broad emission lines, such as CIV 1549. Specifically we investigate the anti-correlation between L_UV and emission line EQW (the Baldwin Effect) and the "blueshifting" of high-ionization emission lines. The blueshift of the CIV emission line is nearly ubiquitous, with a mean shift of 810 km/s for radio-quiet (RQ) quasars and 360 km/s for radio-loud (RL) quasars, and the Baldwin Effect is present in both RQ and RL samples. Composite spectra are constructed as a function of CIV emission line properties in attempt to reveal empirical relationships between different line species and the SED. Within a two-component disk+wind model of the broad emission line region (BELR), where the wind filters the continuum seen by the disk component, we find that RL ...

2010-01-01

307

Standards for limits of air pollutant emission in the GDR  

Energy Technology Data Exchange (ETDEWEB)

Activities of the Referenzlaboratorium Reinhaltung der Luft at Magdeburg as well as existing air pollution standards in the German Democratic Republic are reviewed. The laboratroy coordinates research and standardization in the field of industrial air pollution for the Ministry of Health. The standards provide orientation for emission control by state district health inspectorates. Emission limits (in g/m/sup 3/) which are international standards for 15 selected industries are listed. Emission limits (in g/m/sup 3/) of GDR standards, issued between 1971 and 1984 are also provided. They concern emission of brown coal dust from coal preparation plants, dust and chemical compound emission from metallurgical plants, dust emission from plants of the limestone and cement industry as well as from cupola furnace plants, boiler plants, plants of the wood industry and ...

1986-01-01

308

RESOLVING DOPPLER-FACTOR CRISIS IN ACTIVE GALACTIC NUCLEI: NON-STEADY MAGNETIZED OUTFLOWS  

International Nuclear Information System (INIS)

Magnetically driven non-stationary acceleration of jets in active galactic nuclei results in the leading parts of the flow being accelerated to much higher Lorentz factors than in the case of steady-state acceleration with the same parameters. The higher Doppler-boosted parts of the flow may dominate the high-energy emission of blazar jets. We suggest that highly variable GeV and TeV emission in blazars is produced by the faster moving leading edges of highly magnetized non-stationary ejection blobs, while the radio data trace the slower-moving bulk flow. Thus, the radio and gamma-ray emission regions have different, but correlated, Doppler factors. High-energy emission is generated, typically within the optically thick core, in the outer parts of the broad-line emission region, avoiding the radiative drag on the faster parts of the flow. The radio emission ...

2010-10-10

309

Off-road compression-ignition engine emission regulations under the Canadian Environmental Protection Act 1999 : guidance document  

Energy Technology Data Exchange (ETDEWEB)

This guide explained the requirements for Off-Road Compression Ignition Engine Emission Regulations established under the Canadian Environmental Protection Act. The regulations are enforced by Environment Canada, which authorizes and monitors the use of the national emissions mark. The regulations prescribe standards for off-road engines that operate as reciprocating, internal combustion engines, other than those that operate under characteristics similar to the Otto combustion cycle and that use a spark plug or other sparking device. The regulations apply to engines that are typically diesel-fuelled and found in construction, mining, farming and forestry machines such as tractors, excavators and log skidders. Four different types of persons are potentially affected by the regulations: Canadian engine manufacturers; distributors of Canadian engines or machines containing Canadian engines; importers of engines or machines for the purpose of ...

2006-03-15

310

Off-road compression-ignition engine emission regulations under the Canadian Environmental Protection Act 1999 : guidance document  

International Nuclear Information System (INIS)

This guide explained the requirements for Off-Road Compression Ignition Engine Emission Regulations established under the Canadian Environmental Protection Act. The regulations are enforced by Environment Canada, which authorizes and monitors the use of the national emissions mark. The regulations prescribe standards for off-road engines that operate as reciprocating, internal combustion engines, other than those that operate under characteristics similar to the Otto combustion cycle and that use a spark plug or other sparking device. The regulations apply to engines that are typically diesel-fuelled and found in construction, mining, farming and forestry machines such as tractors, excavators and log skidders. Four different types of persons are potentially affected by the regulations: Canadian engine manufacturers; distributors of Canadian engines or machines containing Canadian engines; importers of engines or machines for the purpose of ...

1999-01-01

311

Near infrared to red and yellow to blue upconversion emissions from Pr"3"+: ZrF_4-BaF_2-LaF_3-YF_3-AlF_3-NaF glasses  

International Nuclear Information System (INIS)

This paper describes the development and a detailed analysis carried out on the luminescence characteristics of Pr"3"+ doped ZrF_4-BaF_2-LaF_3-YF_3-AlF_3-NaF glasses. In the present work our objectives are to elucidate the possible mechanisms that are responsible for NIR to red upconversion process and yellow to blue upconversion emission in terms of energy level schemes from the praseodymium containing fibre optical glass composition. We have studied their different physical and optical properties. Besides our investigation on the upconversion emission of these glasses, normal fluorescence studies have also been undertaken in explaining the mechanisms in demonstrating bright red and blue emissions upon excitations at visible and UV wavelengths. Besides these measurements works, a bright blue colour emission was observed under an UV source (202 nm) and upconverted prominent red ...

2004-04-15

312

Low-energy ion-induced electron emission from gas-covered surfaces  

International Nuclear Information System (INIS)

Measurements of ion-induced electron emission have been performed with helium and argon ions with energies between 300 and 900 eV on W, W with 10% Ti, Al, Al with 1% Cu, Al with 1% Si, Si, and Be. This article describes many of the important surface characteristics that influence the ion-induced electron emission. For low-energy ions, the substrate material was found to be less important as the velocity of the incident ion decreased. In the case of incident Ar"+ the substrate material had a negligible effect on the emission for this energy range. The presence of an adsorbed layer enhanced emission in all cases. Heating the substrates resulted in oxidation of the surfaces and a subsequent increase in emission. The electron emission from aluminum samples with smaller grain sizes was higher than samples of identical composition with larger grains. This effect is ...

313

Emission factors of polybrominated diphenyl ethers (PBDEs) from plastics processing and recycling facilities  

Energy Technology Data Exchange (ETDEWEB)

With regard to polybrominated diphenyl ether (PBDE), there is few scientific knowledge on the emission patterns into the environment and exposure pathways to humans, and basic information is insufficient to consider what measures effective are. For the purpose of promoting risk reduction of target substances more effectively and efficiently, it is desirable to comprehend accurately the causal chain from the target substances utilization to the risk intake, and to evaluate the measures covering the whole applications of target substances. As the existing researches on the PBDE emission inventory, there are EU risk assessment report (European Chemical Bureau 2000, 2002, 2003), Danish EPA (1999), Palm et al.(2002) and Alcock et al. (2003). In addition, emissions of DecaBDE are published in TRI (Toxic Release Inventory) of US EPA. However, the primary information of the previous inventories is often the same and estimations ...

2004-09-15

314

Emission characterization and evaluation of natural gas-fueled cogeneration microturbines and internal combustion engines  

International Nuclear Information System (INIS)

The increasing diffusion of small-scale energy systems within the distributed generation (DG) paradigm is raising the need for studying the environmental impact due to the different DG solutions in order to assess their sustainability. Addressing the environmental impact calls for building specific models for studying both local and global emissions. In this framework, the adoption of natural gas-fueled DG cogeneration technologies may provide, as a consequence of cogeneration enhanced overall energy efficiency and of natural gas relatively low carbon content, a significant reduction of global impact in terms of CO2 emissions with respect to the separate production of electricity and heat. However, a comprehensive evaluation of the DG alternatives should take into account as well the impact due to the presence of plants spread over the territory that could increase the local pollution, in particular due to CO and NOx, and thus could worsen the ...

2008-10-01

315

Effect of rich and high turbulence combustion on emissions and flame behavior in a direct-injection diesel engine; Chokusetsu funshashiki diesel kikan ni okeru haki tokusei to kaen kyodo ni oyobosu kano koranryu nensho no eikyo  

Energy Technology Data Exchange (ETDEWEB)

This study tried to reduce NO{sub x} and particulate emissions simultaneously in a high speed direct-injection diesel engine. Fuel-rich combustion was used to reduce NO{sub x} emission at initial combustion stage and high turbulence combustion was used to reduce particulate emission at diffusion combustion stage. Experiments were carried out to investigate the effects of high squish combustion chambers with small throat on combustion process and exhaust emissions. Results showed that in the high squish combustion chamber, both NO{sub x} and particulate emissions reduced with retarded injection timing. Endoscopic high speed photography was employed to analyze experimental results. In the original combustion chamber at the early combustion stage, the high luminosity flame tended to spread out of the cavity. Fuel-rich mixture burned slowly over the piston crown. In the high squish ...

1999-09-25

316

Atmospheric emissions inventory data for heavy-duty vehicles  

International Nuclear Information System (INIS)

Heavy-duty trucks and buses are substantial contributors to the atmospheric oxides of nitrogen (NO_x) inventory, but prediction of their emissions in real use remains inchoate. Continuous emissions of NO_x were recorded from Chassis dynamometer testing of eight vehicles using a variety of transient cycles, including the Central Business District schedule. NO_x data were treated to account for sampling time lag and presented against instantaneous vehicle axle power. Data were repeatable from run to run and test schedule, but vehicle type and test cycle both influenced the instantaneous emissions rates. However, the resulting correlations may be used for mobile source NO_x contribution estimation when combined with vehicle activity data. The emissions data were also presented as NO_x/CO_2, which are valuable for comparison with remote sensing emissions data. The overall average ratio ...

1999-01-01

317

Low energy, low emissions: SO_2, NO_x and CO_2 in Western Europe. Working paper  

International Nuclear Information System (INIS)

A link is made in this paper between proposed low energy scenarios for different Western European countries and the amount of pollutants that may result from these scenarios. Air pollutant emissions are calculated for the ten countries for which low energy scenarios are available. These scenarios emphasize stringent energy efficiency, maximizing the use of renewable (other than nuclear) energy, and minimizing the use of fossil fuels. Under these low energy scenarios, the average per capita energy use (year 2030) in the ten countries is estimated as 97 GJ/person, which is a decrease of 38% relative to 1980. Using the energy consumption figures from the low energy scenarios, together with sector- and fuel-specific emission factors from Europe, the resulting emissions of SO_2 , NO_x , and CO_2 were computed. These estimates do not take into account any add-on pollution controls over and above what was in place in 1980, or ...

318

Aircraft emissions at Turkish airports  

International Nuclear Information System (INIS)

This paper deals with estimating aircraft landing and take-off (LTO) emissions (HC, CO, NO_x, SO_2) at 40 Turkish airports including the biggest airports, i.e. Ataturk International Airport (AIA) in Istanbul, Antalya Airport in Antalya and Esenboga Airport in Ankara in 2001. The calculation model is based on flight data recorded by the State Airports Authority. The flight data include the type and number of aircraft, number of passengers, amount of cargo etc., which depend on day-time and date. For the emission calculations the International Civil Aviation Organization (ICAO)-Engine emission data bank, which includes minimum and maximum values for both fuel flow rates and emissions factors, is used. By using first the minimum and then the maximum values from the data bank, two estimations of aircraft LTO emissions at Turkish airports are calculated: i.e. minimum and maximum ...

319

Swedish Environmental and Economic Accounts. Physical accounts for energy and emissions to air 1993 and 1995  

International Nuclear Information System (INIS)

This Statistical Report presents results from the physical Swedish Environmental and Economic Accounts for the years 1993 and 1995 according to the classification NACE. The Environmental Economic Accounts constitute an integrated and comprehensive system for environmental and economic statistics. Environmental data are systematically presented together with economic data in a common framework. The system can be used for analyses of various relationships between economy and environment. Data on emissions to air of carbon dioxide, sulphur dioxide, nitrogen oxides, carbon monoxide, methane, nitrous oxide and ammonia are presented for 39 industries, government services and private consumption. The use of energy commodities in monetary and physical terms are also presented for the same sectors. Economic, energy and emission data are also presented in environmental and economic profiles and indicators. Environmental and economic profiles provide an ...

2000-03-01

320

Red-shift of emission wavelength caused by reabsorption mechanism of europium activated Ca-#alpha#-SiAlON ceramic phosphors  

International Nuclear Information System (INIS)

The optical properties of divalent europium activated Ca-#alpha#-SiAlON were investigated and the excitation and emission processes were discussed. The emission wavelength is influenced by the activator concentration of Eu more than the codopant concentration of Ca, in case of the same matrix composition of #alpha#-SiAlON. The red-shift of emission increases when the concentration of Eu increases. In addition, it was revealed that the red-shift of emission would be caused by the construction of the package of optical device. The correlated color temperature becomes low by the red-shift for the white light-emitting diode (LED) lamp using Ca-#alpha#-SiAlON:Eu phosphor when the phosphor powder concentration increases in the transparent resin which coats the primary light source of a blue LED die. The additional red-shift can be observed when the excessive amount of phosphor coating is intentionally poured ...

2007-10-01

321

Radial distribution of superthermal electrons measured with ECE (abstract)  

International Nuclear Information System (INIS)

To aid in the study of lower hybrid current drive as a means of current profile control, the radial profile and velocity distribution of the fast current-carrying electrons and their time evolution must be known. As part of the recent effort to understand this fast electron transport, a diagnostic has been installed on PBX-M to measure the electron cyclotron emission from the fast electrons. An oblique horizontal view of upshifted cyclotron emission in the midplane can give radial as well as velocity space information about the fast electrons. Emission in X mode frequencies refracted by the right-hand cutoff is radially localized. The observed emission at a specific frequency comes only from the radial region r_t_u_r_n=#0. Emission measured by this new diagnostic has been found to be radially localized as predicted. It is also expected that localized moments of the distribution ...

0854-01-01

322

Port pollution and exhaust emissions from ships  

Energy Technology Data Exchange (ETDEWEB)

This presentation gives the results of a research programme aimed at evaluating exhaust emissions from ships moving within confined coastal zones, as in Piraeus harbour. The level of various exhaust emissions were estimated on the basis of a mathematical model applied for each sea traffic element (ship). Hourly and daily records of all ships` movements in different parts of the harbour were compiled, covering extended periods of time and associated with different shipping operational characteristics (peaks, lows, etc). In order to correlate the exhaust emissions from shipping with the quality of the air in the area of interest, land-based measurements for the same pollutants were carried out in selected locations, near the port and in the greater Athens area. This enabled the investigation of time and spatial diffusion of exhaust emissions from shipping within the area of interest, taking into account ...

1995-12-31

323

NAPAP (National Acid Precipitation Assessment Program) emissions inventory (version 2): Development of the national utility reference file, 1985. Final report, January-September 1989  

Energy Technology Data Exchange (ETDEWEB)

The report gives results of a project conducted to create a file containing comprehensive data on all electric utilities in the US. The National Acid Precipitation Assessment Program's (NAPAP's) emissions inventory activities focus on the estimation of emissions from pollutants that contribute to acid deposition. Electric utilities, which emit a large share of total acid deposition precursor emissions, are important for modeling analyses. Data reported by states to the National Emissions Data System (NEDS) for the 1985 NAPAP Emissions Inventory and data reported to the U.S. Department of Energy (DOE) on EIA Form 759, EIA Form 767, FERC Form 423, and the Integrated Data Base System (IDBS) were matched and combined. The resulting 1985 National Utility Reference File (NURF) contains detailed unit level data for nearly 10,000 electricity generating plants.

1989-11-01

324

Municipal waste combustion study: costs of flue-gas-cleaning technologies. Final report  

Science.gov (United States)

This report is an assessment of emission-control costs for municipal-waste combustors (MWCs). The details of the cost estimates, including their development, components, and cost premises, are addressed. A model-plant approach was used in the sizing and costing of the emission control systems. Due to differences in the feed-waste characteristics, combustion parameters, and emissions, separate cost estimates were required for mass burning (MB), modular (MOD), refuse-derived fuel (RDF), and fluid-bed combustion (FBC) type furnaces. Cost estimates were developed for control of particulate matter (PM) emissions only and for control of both acid gas and PM emissions from the MWC model plants. Controlled PM emission levels of 0.03, 0.02, and 0.01 gr/dscf, corrected to 12% CO/sub 2/, and 90 and 70% reductions of HC1 and SO2, respectively, were used to develop the ...

1987-06-01

325

Extended radio emission in MOJAVE Blazars: Challenges to Unification  

CERN Document Server

We present the results of a study on the 1.4 GHz kpc-scale radio emission in the complete flux density limited MOJAVE sample, comprising 135 radio-loud AGNs. While extended emission is detected in the majority of the sources, about 7% of the sources exhibit only radio core emission. Many BL Lacs exhibit extended radio power and kpc-scale morphology typical of powerful FRII jets, while a substantial number of quasars possess radio powers intermediate between FRIs and FRIIs. This poses challenges to the simple radio-loud unified scheme, which links BL Lacs to FRIs and quasars to FRIIs. We find a significant correlation between extended radio emission and pc-scale jet speeds: the more radio powerful sources possess faster jets. This indicates that the 1.4 GHz (or low frequency) radio emission is indeed related to jet kinetic power. Various properties such as extended radio power and ...

2010-01-01

326

Exhaust emissions from a Diesel engine fueled with transesterified waste olive oil  

Energy Technology Data Exchange (ETDEWEB)

The exhaust emissions of a Diesel direct injection Perkins engine fueled with waste olive oil methyl ester were studied at several steady-state operating conditions. Emissions were characterized with neat biodiesel from used olive oil and conventional Diesel fuel. Results revealed that the use of biodiesel resulted in lower emissions of CO (up to 58.9%), CO{sub 2} (up to 8.6%, excepting a case which presented a 7.4% increase), NO (up to 37.5%), and SO{sub 2} (up to 57.7%), with increase in emissions of NO{sub 2} (up to 81%, excepting a case which presented a slight reduction). Biodiesel also presented a slight increase in brake-specific fuel consumption (lower than 8.5%) that may be tolerated due to the exhaust emission benefits. Combustion efficiency remained constant using either biodiesel or Diesel fuel. The proposed alternative for Diesel fuel could significantly decrease the ...

2003-07-01

327

Emissions from power plants 1987-1996; Emissioner fra kraftvaerkerne 1987-1996  

Energy Technology Data Exchange (ETDEWEB)

The document gives statistics on the pollutive emissions from Danish power plants during the period 1987-1996, the main pollutants being sulphur dioxide, nitrogen oxides and carbon dioxide. Data on efficiency levels relative to the production of electricity and heating and on the power plants` contribution to the total emission of CO{sub 2}, NO{sub x}, and SO{sub 2} from energy consumption in Denmark, are presented, and also as corrected for the net import of electricity. Other data on the emission of each of these chemicals by power plants are presented as factual, and corrected in accordance with the net import of electricity, and as factual per consumed and produced energy unit at the power plants. Short notes on related Danish legislation are found in addition to information on sources, methods and definitions used as a basis for the production of this document. Emission from power stations is ...

1997-08-01

328

Electricity generation: options for reduction in carbon emissions  

Energy Technology Data Exchange (ETDEWEB)

Historically, the bulk production of electricity has been achieved by burning fossil fuels, with unavoidable gaseous emissions, including large quantities of carbon dioxide: an average-sized modern coal-burning power station is responsible for more than 10 Mt of CO{sub 2} each year. This paper details typical emissions from present-day power stations and discusses the options for their reduction. Acknowledging that the cuts achieved in the past decade in the UK CO{sub 2} emissions have been achieved largely by fuel switching, the remaining possibilities offered by this method are discussed. Switching to less-polluting fossil fuels will achieve some measure of reduction, but the basic problem of CO{sub 2} emissions continues. Of the alternatives to fossil fuels, only nuclear power represents a zero-carbon large-scale energy source. Unfortunately, public concerns over safety and radioactive waste have ...

2002-07-01

329

Economic growth and pollutant emissions in Tunisia: An empirical analysis of the environmental Kuznets curve  

Energy Technology Data Exchange (ETDEWEB)

This paper investigates the relationship between economic growth and pollutant emissions for a small and open developing country, Tunisia, during the period 1961-2004. The investigation is made on the basis of the environmental Kuznets curve hypothesis, using time series data and cointegration analysis. Carbon dioxide (CO{sub 2}) and sulfur dioxide (SO{sub 2}) are used as the environmental indicators, and GDP as the economic indicator. Our results show that there is a long-run cointegrating relationship between the per capita emissions of two pollutants and the per capita GDP. An inverted U relationship between SO{sub 2} emissions and GDP has been found, with income turning point approximately equals to $1200 (constant 2000 prices) or to $3700 (in PPP, constant 2000 prices). However, a monotonically increasing relationship with GDP is found more appropriate for CO{sub 2} emissions. Furthermore, the ...

2010-02-15

330

Economic growth and pollutant emissions in Tunisia: An empirical analysis of the environmental Kuznets curve  

International Nuclear Information System (INIS)

This paper investigates the relationship between economic growth and pollutant emissions for a small and open developing country, Tunisia, during the period 1961-2004. The investigation is made on the basis of the environmental Kuznets curve hypothesis, using time series data and cointegration analysis. Carbon dioxide (CO2) and sulfur dioxide (SO2) are used as the environmental indicators, and GDP as the economic indicator. Our results show that there is a long-run cointegrating relationship between the per capita emissions of two pollutants and the per capita GDP. An inverted U relationship between SO2 emissions and GDP has been found, with income turning point approximately equals to $1200 (constant 2000 prices) or to $3700 (in PPP, constant 2000 prices). However, a monotonically increasing relationship with GDP is found more appropriate for CO2 emissions. Furthermore, the causality results show that ...

2010-02-01

331

Economic growth and pollutant emissions in Tunisia. An empirical analysis of the environmental Kuznets curve  

Energy Technology Data Exchange (ETDEWEB)

This paper investigates the relationship between economic growth and pollutant emissions for a small and open developing country, Tunisia, during the period 1961-2004. The investigation is made on the basis of the environmental Kuznets curve hypothesis, using time series data and cointegration analysis. Carbon dioxide (CO{sub 2}) and sulfur dioxide (SO{sub 2}) are used as the environmental indicators, and GDP as the economic indicator. Our results show that there is a long-run cointegrating relationship between the per capita emissions of two pollutants and the per capita GDP. An inverted U relationship between SO{sub 2} emissions and GDP has been found, with income turning point approximately equals to 1200 (constant 2000 prices) or to 3700 (in PPP, constant 2000 prices). However, a monotonically increasing relationship with GDP is found more appropriate for CO{sub 2} emissions. Furthermore, the ...

2010-02-15

332

Determination of the emission zone in a single-layer polymer light-emitting diode through optical measurements  

Science.gov (United States)

We study the emission zone in a single-layer polymer light-emitting diode. The emission zone is found by studying the angular distribution of the electroluminescence. The emission is modeled by accounting for optical interference. We account for birefringence of the anode layer in our model. The active polymer was, however, found to be isotropic. The anode consists of a single-layer of the conducting polymer complex poly(3,4-ethylenedioxythiophene) and poly(styrene sulfonate) (PEDOT-PSS), with enhanced conductivity. As a cathode we use plain aluminum. By using only PEDOT-PSS we avoid having a thin metal layer or indium-tin-oxide as the anode in the path of the escaping light. The active material is a substituted polythiophene with excellent film forming properties. A comparison between the experimental and calculated angular distribution of light emission from a single-layered polymer light-emitting ...

2001-06-01

333

A systematic approach for meeting future diesel engine emission regulations; Systemansatz zur Erfuellung der zukuenftigen Emissionsgesetzgebung fuer Dieselmotoren  

Energy Technology Data Exchange (ETDEWEB)

A method was developed in which the potential of various measures is assessed systematically with a view to meeting the future EU5 emission specifications. Varied boundary conditions are taken into account, and their influence on the PM-NOx tradeoff was investigated. The relative cost is compared to an existing EU4 injection system. It was attempted to apply these measures to the impending US regulations (Tier2 Bin5) and to offer an outlook to EU6. The result shows that it is possible in principle for a car of the 1600 kg class to reduce NOx emissions while maintaining the EU4-PM emission standards.In the case of envisaged serial application subject to emission standards like US Tier 2 and EU6, much work is still required in terms of system robustness and life. In higher-class vehicles, the NOx reduction potential is lower, and it will be more difficult to make do without NOx treatment, especially with ...

2006-07-01

334

The green power option to gain market advantage  

Energy Technology Data Exchange (ETDEWEB)

Deregulation of the electric power industry in Alberta holds the prospect of providing greater choice for customers. One such option will be `green power` which is provided by renewable energy technologies. The energy produced would be without environmental impacts such as air emissions, water pollution, flooding, thermal emissions or waste by-products. Wind power, small scale hydro power, photovoltaics and biomass technologies have been termed as `green power`. The choices that customers make will not be focused on price alone. Market forces are emerging to demand reduction in emissions which will result in a market for `green energy` products and facilitate achieving goals for a sustainable future.

1997-03-01

335

The effects of aircraft engine pollutant emission measurement variability on engine certification policy  

Science.gov (United States)

Divergence between aircraft engine emission regulations proposed by EPA and ICAO is discussed. Every engine, upon entering service, requires a certificate as to its compliance with emission standards. It is shown that despite the large variability in the measurements, it is possible to devise a certification procedure requiring the testing of one engine only. Statistical modeling of such a test at the 5% significance level is described. Values of the parameter standard deviation/mean recommended as certification standards for various pollutants are given. Features of a rational certification scheme to be formulated are outlined.

1978-10-01

336

Sudden freeze-out vs continuous emission: duality in hydro-kinetic approach to A+A collisions  

CERN Document Server

The problem of spectra formation in hydrodynamic approach to A+A collisions is discussed. It is analyzed in terms of the two different objects: distribution and emission functions. We show that though the process of particle liberation, described by the emission function, is, usually, continuous in time, the observable spectra can be also expressed by means of the Landau/Cooper-Frye prescription. We argue that such an approximate duality results from some symmetry properties that systems in A+A collisions reach to the end of hydrodynamic evolution and reduction of the collision rate at post hydrodynamic stage

2004-01-01

337

Role of the transport in management of MSW. Part 1.: global balance  

International Nuclear Information System (INIS)

An important aspect, which has to be considered in terms of municipal solid waste (MSW) management, is the stage of collection. The emissions generated from these systems can arrive to values that are of the same order of magnitude of emissions from combustion of waste in waste-to-energy plants. The present work faces the problem of transport, from intermediate station to the center of final combustion, placing attention to the emissions from scenarios that has been selected between real systems of management. This analysis can lead to highlight some important elements that can be useful to minimize the impacts.

338

Preparatory Signal Detection for Annex I Countries under the Kyoto Protocol. A Lesson for the Post-Kyoto Policy Process  

Energy Technology Data Exchange (ETDEWEB)

The focus of this study is on the preparatory detection of uncertain net greenhouse gas (GHG) emission changes (also termed emission signals) under the Kyoto Protocol. The crucial question to be addressed is: How well do we need to know net emissions if we want to detect a specified emission signal after a given time? No restrictions exist as to what concerns the net emitter, which may be any GHG source or sink. Annex I countries are chosen as net emitters, simply for reasons of data availability and because of the excellent possibility of comparing net emitters (inter-country comparison). The countries' emissions - in an increasing number of cases even their uncertainties - are available permitting the application of preparatory signal detection techniques, which are suited to address the aforementioned question. We currently discuss four hierarchically-ordered detection ...

2004-06-14

339

Optimized hydrogen piston engines  

Energy Technology Data Exchange (ETDEWEB)

Hydrogen piston engines can be simultaneously optimized for improved thermal efficiency and for extremely low emissions. Using these engines in constant-speed, constant-load systems such as series hybrid-electric automobiles or home cogeneration systems can result in significantly improved energy efficiency. For the same electrical energy produced, the emissions from such engines can be comparable to those from natural gas-fired steam power plants. These hydrogen-fueled high-efficiency, low-emission (HELE) engines are a mechanical equivalent of hydrogen fuel cells. HELE engines could facilitate the transition to a hydrogen fuel cell economy using near-term technology.

1994-05-10

340

Modified spontaneous emission rate in three-dimensional layer-by-layer photonic crystals with planar defects  

Science.gov (United States)

A finite three-dimensional layer-by-layer photonic crystal with planar defects in a layer is shown to drastically modify the spontaneous emission rate of an embedded dipole. Finite-difference time-domain calculations with one quarter symmetric boundary condition and perfectly matched layer demonstrate the strong enhancement effects induced by the cavity resonance of defect modes and band-edge resonant modes. Simulation shows that the emission spectra are quite different when the position or polarization of the dipole is changed. Moreover, the extraction efficiency is calculated to observe the percentage of light leakage through a substrate.

2010-01-01

341

Emission and excitation spectra of feldspar inclusions within quartz  

Energy Technology Data Exchange (ETDEWEB)

Emission spectra obtained for three irradiated granular quartz samples under 1.43 eV excitation exhibited the 2.2 and 3.1 eV emission bands characteristic of feldspars. Excitation spectra of these same samples and several others show the 1.44 eV resonance typical of feldspars. This provides convincing evidence that the 2.2 and 3.1 eV infrared stimulated luminescence observed in these granular quartz samples arises from feldspar inclusions.

2004-02-01

342

Emission Line Spectra in the Soft X-Ray Region 20-75 (Angstrom)  

Energy Technology Data Exchange (ETDEWEB)

As part of a project to complete a comprehensive catalogue of astrophysically relevant emission lines in support of new-generation X-ray observatories using the Lawrence Livermore electron beam ion traps EBIT-I and EBIT-II, we studied emission lines of argon and sulfur in the soft X-ray and extreme ultraviolet region. Here we present observations of Ar IX through Ar XVI and S VII through S XIV between 20 and 75 {angstrom} to illustrate our work.

2002-06-18

343

A small particle selective emitter for thermophotovoltaic energy conversion  

Energy Technology Data Exchange (ETDEWEB)

This paper presents an analysis of the performance of a selective emitter using small particles of rare earth compounds stable at high temperatures in a low emittance inert gas stream. An expression for the spectral emissive power excluding radiation scattering was derived to include the radiation in the emission band, produced by electronic transitions of the rare earth ion, and the continuum radiation outside the emission band produced by the rare earth host. Preliminary results suggest that a selective emitter based on suspended rare earth oxide particles will have high efficiency and merits further experimental investigation. {copyright} {ital 1996 American Institute of Physics.}

1996-02-01

344

X-ray Emission as a Probe of the Wind-Driven Shock in WR 140  

Science.gov (United States)

single star evolution. To understand the evolution of massive stars and their role in shaping the galaxy, understanding of the distribution of ...

345

Use of Morphological Signal Processing and Computational - NASA  

Science.gov (United States)

Al-Balushi KR, Samanta B. Gear fault diagnosis using energy-based features of acoustic emission signals. Proc. IMechE, Part I: ...

346

Trace analysis in cadmium telluride by heavy ion induced X-ray emission and by SIMS  

International Nuclear Information System (INIS)

The possibilities of using both selective heavy ion induced X-ray emission and secondary ion mass spectroscopy (SIMS), for the identification of impurities present at low concentrations in cadmium telluride are examined. The relative concentrations of the impurities along CdTe crystals have been determined by exciting the X-ray emission of the elements in several slices with Ar and Kr ions and by comparing the relative characteristic X-ray emission yields. As a consequence of the quasimolecular inner shell ionization mechanism in heavy ion-atom collisions, Ar and Kr ions allow a strong excitation of the main impurities seen by SIMS namely Si, Cl and Ge, As, with only a minor contribution of Cd and Te. From the changes of the concentrations of the various impurities along the crystal, informations about segregation coefficients and compensation can be obtained.

2007-02-01

347

This perspective view of Venus, generated by computer  

Science.gov (United States)

This perspective view of Venus, generated by computer from NASA's Magellan data and color-coded with emissivity, shows part of the lowlands to the north of ...

348

The toxicological evaluation of realistic emissions of source aerosols study: statistical methods  

British Library Electronic Table of Contents (United Kingdom)

The Toxicological Evaluation of Realistic Emissions of Source Aerosols (TERESA) study involved withdrawal, aging, and atmospheric transformation of emissions of three coal-fired power plants. Toxicological evaluations were carried out in rats exposed to different emission scenarios with extensive exposure characterization. Data generated had multiple levels of resolution: exposure, scenario, and constituent chemical composition. Here, we outline a multilayered approach to analyze the associations between exposure and health effects beginning with standard ANOVA models that treat exposure as a categorical variable. The model assessed differences in exposure effects across scenarios (by plant). To assess unadjusted associations between pollutant concentrations and health, univariate analyses...

2011-01-01

349

The influence of chemically active gas on the light emission of metallic targets bombarded by positive ions  

International Nuclear Information System (INIS)

The introduction of oxygen in the vicinity of a metallic target surface, bombarded with positive argon ions of twenty kiloelectron-volts, increases the number of sputtered atoms in the excited state. This phenomenon of exaltation, very sensitive in the case of nickel and aluminium, is much less marked in the case of molybdenum. Moreover, the emission of excited particles coming from the beam's ions is not modified. A quantum-mechanical model of a kinetic emission process, which permits the interpretation of the clean metallic target's emission phenomena, seems insufficient to explain all of the results obtained in the presence of oxygen. In this last case one can therfore use a thermodynamic model in which excited metallic particles can be formed directly by chemical surface reactions of neutralization or reduction. (orig.).

352

The effect of oxygen enriched air obtained by gas separation membranes from the emission gas of diesel engines  

British Library Electronic Table of Contents (United Kingdom)

Gas separation membranes with polydimethylsiloxane(PDMS)/polystyrene(PS) were prepared by using the sequential interpenetrating polymer network (IPN) method with various PS contents (10?70wt%). These gas separation membranes can be applied to reduce the smoke density in the emission gas of diesel engines. PS content has a pronounced effect on the membrane performance. It was found that the optimized PS contents in the final membrane were 50wt%. The emission capacities of diesel engines used in this study were 632 cc and 11,149 cc. When the oxygen separation membrane was used in the diesel engines, the smoke density of both diesel engines was remarkably reduced (35?73%). The oxygen concentration in the inlet air affects the composition of the emission gases. Especially, hydrocarbon (HC) dec...

2006-01-01

353

Statement of work for analytical services provided by PNNL`sanalytical chemistry laboratory  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this statement of work (SOW) is to establish laboratory analytical criteria and requirements for radioactive airborne emissions measurement sample and/or analysis activities.

1997-06-30

354

Soot and NO(x) emissions and combustion characteristics of low heat rejection direct injection diesel engines. Final report, 1 September 1989-31 August 1994  

Energy Technology Data Exchange (ETDEWEB)

Performance and emissions data were gathered on a normally aspirated single cylinder DI engine with various combinations of ceramic coatings installed. Thin ceramic thermal barrier coatings were applied to the piston crown and bowl, the head and valves, and the cylinder liner. The coated piston and head were run singly and in combination with the cylinder liner to investigate the effects of these different coated surfaces on emissions and performance. Coating the piston crown alone results in generally lower cylinder pressure, lower brake specific fuel consumption and lower NO(x) emission compared to the baseline engine. Soot emission is typically increased below 2000 RPM and decreased above 2000 RPM. Coating the head alone reduces cylinder pressure, but generally increases specific fuel consumption and NO(x) and soot emission. The KIVA-II code was used to model the Hydra engine ...

1994-01-10

355

Research on pitting corrosion of steam generator heat transfer tubes based on acoustic emission  

International Nuclear Information System (INIS)

Corrosion of steam generator heat transfer tubes (SGHTT) is one of the important problems which affect safety operation of nuclear power plants (NPP), and the hazard of pitting corrosion of heat transfer tubes is the most serious. With an acoustic emission device, the signals during a corrosion test on SGHTT were collected and analyzed, and the corrosion points in the tubes were located accurately. The results show that pitting corrosion of heat transfer tubes has passed through three periods in its development: expansion phase, stationary phase and rapid developing phase. The corrosion damage of HTT can be found earlier with acoustic emission than any other non-destructive testing methods. Acoustic emission can be used for on-line and real-time monitoring of the safety and operation of the steam generator and has therefore a great significance. (orig.)

2010-09-01

356

Reference scenarios for deforestation and forest degradation in support of REDD: a review of data and methods  

Energy Technology Data Exchange (ETDEWEB)

Global climate policy initiatives are now being proposed to compensate tropical forest nations for reducing carbon emissions from deforestation and forest degradation (REDD). These proposals have the potential to include developing countries more actively in international greenhouse gas mitigation and to address a substantial share of the world's emissions which come from tropical deforestation. For such a policy to be viable it must have a credible benchmark against which emissions reduction can be calculated. This benchmark, sometimes termed a baseline or reference emissions scenario, can be based directly on historical emissions or can use historical emissions as input for business as usual projections. Here, we review existing data and methods that could be used to measure historical deforestation and forest degradation reference scenarios including ...

2008-04-15

357

Reference scenarios for deforestation and forest degradation in support of REDD: a review of data and methods  

International Nuclear Information System (INIS)

Global climate policy initiatives are now being proposed to compensate tropical forest nations for reducing carbon emissions from deforestation and forest degradation (REDD). These proposals have the potential to include developing countries more actively in international greenhouse gas mitigation and to address a substantial share of the world's emissions which come from tropical deforestation. For such a policy to be viable it must have a credible benchmark against which emissions reduction can be calculated. This benchmark, sometimes termed a baseline or reference emissions scenario, can be based directly on historical emissions or can use historical emissions as input for business as usual projections. Here, we review existing data and methods that could be used to measure historical deforestation and forest degradation reference scenarios including FAO ...

358

Reducing Emissions from Deforestation in Developing Countries: The Way Forward  

Science.gov (United States)

This paper summarizes the main features of four current REDD proposals: Compensated Reduction, Papua New Guinea et al; Joint Research Center; and Brazil. ... ...

360

Performance and heat release analysis of a pilot-ignited natural gas engine  

Energy Technology Data Exchange (ETDEWEB)

The influence of engine operating variables on the performance, emissions and heat release in a compression ignition engine operating in normal diesel and dual-fuel modes (with natural gas fuelling) was investigated. Substantial reductions in NO{sub x} emissions were obtained with dual-fuel engine operation. There was a corresponding increase in unburned hydrocarbon emissions as the substitution of natural gas was increased. Brake specific energy consumption decreased with natural gas substitution at high loads but increased at low loads. Experimental results at fixed pilot injection timing have also established the importance of intake manifold pressure and temperature in improving dual-fuel performance and emissions at part load. (Author)

2002-09-01

361

On the premixed combustion in a direct-injection diesel engine  

Energy Technology Data Exchange (ETDEWEB)

The factors influencing premixed burning and the importance of premixed burning on the exhaust emissions from a small high-speed direct-injection diesel engine were investigated. The characteristics of premixed and diffusion burning were examined using a single-zone heat-release analysis. The mass of fuel burned in premixed combustion was found to be linearly related to the product of engine speed and ignition-delay time and to be essentially independent of the total amount of fuel injected. Accordingly, the premixed-burned fraction increased with increasing engine speed, with decreasing fuel-air ratio and with retarding injection timing. The hydrocarbon emissions did not correlate well with the premixed-burned fraction. In contrast, the oxides of nitrogen emissions were found to increase with decreasing premixed-burned fraction, indicating that diffusion burning, and not premixed burning, is the primary source of oxides of ...

1987-04-01

362

Non-equilibrium particle emission in 45 MeV #alpha# particle bombardment of "1"5"9Tb  

International Nuclear Information System (INIS)

Mar 1982. p. 36-37. Germany Didelez, JP Paris-11 Univ., 91 - Orsay (France).

1982-03-01

363

Newton's first law and the existence of free tachyons  

International Nuclear Information System (INIS)

NEWTON's first law prohibits the coupling of free tachyons to ordinary matter, if it is interpreted as selection rule interdicting emission without change of the rest-mass of the emitting system.

364

Neutron star evolution and emission  

Science.gov (United States)

This is the final report of a three-year, Laboratory Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The authors investigated the evolution and radiation characteristics of individual neutron stars and stellar systems. The work concentrated on phenomena where new techniques and observations are dramatically enlarging the understanding of stellar phenomena. Part of this project was a study of x-ray and gamma-ray emission from neutron stars and other compact objects. This effort included calculating the thermal x-ray emission from young neutron stars, deriving the radio and gamma-ray emission from active pulsars and modeling intense gamma-ray bursts in distant galaxies. They also measured periodic optical and infrared fluctuations from rotating neutron stars and search for high-energy TeV gamma rays from discrete celestial sources.

1997-08-01

365

NASA SBIR/STTR Technologies  

Science.gov (United States)

(e.g. enclosed cooktop with built in emissions capture and treatment) . " Test hardware in laboratory, reduced pressure and analog habitat. " Objective 1. ...

366

NASA I Aeronautical Engineering ... - NASA Technical Reports Server  

Science.gov (United States)

Divergence betyveen aircraft engine emission regulations pro- posed by EPA and ICAO is discussed Every engine, upon entering service, requires a certificate ...

367

Mechanism of the electric field effect on the intensity of visible continuum emission from the positive column of gas discharge in a cesium vapor-xenon mixture  

British Library Electronic Table of Contents (United Kingdom)

We have studied the nature of continuum emitted in the visible spectral range from a noncontracted positive column of discharge in a cesium vapor-xenon mixture at a pressure of 45 Torr and at a degree of ionization below 3 ? 10?6. The main contribution to the continuous emission under such conditions is due to electron-xenon atom bremsstrahlung. The intensity of emission has been experimentally and theoretically studied as a function of the electric field strength and electron density in the positive column. It is established that an increase in the visible emission intensity with the electric field strength is related to an increase in the number of hot electrons in plasma.

2007-01-01

370

Ionized gas and radio emission in the barred Seyfert galaxy NGC 5728  

International Nuclear Information System (INIS)

This paper reports extensive new optical and radio observations of NGC 5728, emphasizing the central regions. Deep photographs revealing detail in the faint spiral arms are briefly discussed. Broad-band UBV CCD images obtained to examine the colors of the stellar populations that comprise the bar and central ring are presented. The velocity field and emission maps obtained from imaging spectroscopic measurements in the H-alpha emission line are discussed. Conventional long-slit spectra covering the ionized gas in the nuclear region are described. Detailed maps of the radio emission in the central regions of NGC 5728 are presented. These combined data provide considerable evidence for the inflow of gas into the nuclear region, in response to the nonaxisymmetric gravitational potential of the bar. The possible relation of this phenomenon to the Seyfert nature of NGC 5728 is also considered. 48 references.

371

Interstellar PAH emission in the 11-14 micron region: new insights from laboratory data and a tracer of ionized PAHs  

Science.gov (United States)

The Ames infrared spectral database of isolated, neutral and ionized polycyclic aromatic

1999-01-01

372

Interferometer Observations of Subparsec-scale Infrared Emission in the Nucleus of NGC 4151  

CERN Document Server

We report novel, high-angular resolution interferometric measurements that imply the near-infrared nuclear emission in NGC 4151 is unexpectedly compact. We have observed the nucleus of NGC 4151 at 2.2 microns using the two 10-meter Keck telescopes as an interferometer and find a marginally resolved source ~0.1 pc in diameter. Our measurements rule out models in which a majority of the K band nuclear emission is produced on scales larger than this size. The interpretation of our measurement most consistent with other observations is that the emission mainly originates directly in the central accretion disk. This implies that AGN unification models invoking hot, optically thick dust may not be applicable to NGC 4151.

2003-01-01

373

Influence of performance characteristic of a gaseous fuel supply system on hydrocarbon emissions of a dual-fuel engine  

Energy Technology Data Exchange (ETDEWEB)

The performance of the gaseous fuel supply and its influence on hydrocarbon (HC) emissions of dual-fuel engines have been investigated. A new design of manifold respirators with mixers is also presented in the paper. The design of the gaseous fuel supply system has a great influence on HC emissions in the dual-fuel engine at light load. The problem of scavenging is discussed and solved by using the manifold respirators in the dual-fuel engine. It performs the function of retarding the gaseous fuel entry timing from the moment of intake valve opening, and its delaying effects have been measured and tested. Experimental results show that the manifold respirator gives the best performance in reducing HC emissions compared with a common pipe mixer and a respirator with bo miser. In addition, the mixing effects are sensitive to the mixer configuration. (Author)

2000-11-01

374

Influence of FeSO4 concentration on thermal emissivity of coatings formed on titanium alloy by micro-arc oxidation  

British Library Electronic Table of Contents (United Kingdom)

Ceramic coatings with high emission were fabricated on Ti6Al4V alloy by microarc oxidation (MAO) with additive FeSO4 into the electrolyte. The microstructure, chemical composition and chemical state of the coatings were determined by SEM, XRD, EDS and XPS, respectively. The bonding strength between the coating and substrate was studied by tensile strength test, together with the thermal shock resistance of the coating. The results showed that Fe content in the coating layer significantly affect its thermal emissivity. The relative content of Fe in the coatings surface increased at first and then decreased with increasing the concentration of FeSO4 in electrolytes, so does the emissivity of the coatings. The bonding strength became weaker with increasing the concentration of FeSO4. In addit...

2011-01-01

375

Image Smearing in a Quantum Well Infrared Photodetector ...  

Science.gov (United States)

... Assuming isotropic emission, the 25' half angle cone represents only -9% [= 1/(2(ngaas/nopticglue) 2)] of the spontaneous radiation. ...

1998-12-01

376

GHG emissions, GDP growth and the Kyoto Protocol: A revisit of Environmental Kuznets Curve hypothesis  

British Library Electronic Table of Contents (United Kingdom)

The Kyoto Protocol attempts through political negotiations to guide participating industrialized countries' greenhouse gas (GHG) emissions from a positive growing trend, to reach a peak point (or turning point), and then be reduced to a negative growth. That means the relationship between decreasing GHG emissions and economic growth may be described by an inverted-U curve (or called a bell-shaped curve), which is consistent with the concept of the Environmental Kuznets Curve (EKC) hypothesis.This research observed that the economic development and GHG emissions in Economies in Transition (EITs) exhibit a hockey-stick curve trend (or called quasi-L-shape curve), that also generates a lot of "hot air" which is significant to the implementation of the Kyoto Protocol. In addition, through the ...

2008-01-01

377

Foveal Machine Vision for Mobile Robots using Agent Based Gaze  

Science.gov (United States)

... non- emissive guidance and collision alert, automated transport in dynamic environments, and assembly and inspection. Foveal Vision, Autonomous Agents, ...

378

Formation of particles in combustion of biofuels  

International Nuclear Information System (INIS)

Biomass combustion is an important part in a sustainable energy system, but as well a source of submicron (particles < 1 #mu#m) particles in the air. Consequently, to obtain a good air quality together with increased biomass combustion there is a need for a better understanding of particle formation. This work is a part of a larger project about formation and emissions of particles from biofuel combustion. The report includes the work performed in the project during the year 2004. The aim of the project is to describe the release of inorganic components, which cause particle emissions, during combustion of single fuel particles of biofuel, e.g. wood pellets. The work is carried out by emission measurements, systematic combustion experiments and modelling work. The results are expected to contribute to the understanding of which parameters that influence the formation of fine particles and thus gain a better insight into ...

379

Far-Infrared Spontaneous Intraband Emission from Laser ...  

Science.gov (United States)

... The fact, that such a spontaneous radiation have been observed, may be considered as the first step of development of the FIR laser based on ...

1998-06-01

380

Exploratory Report Aluminium and Aluminium Compounds.  

Science.gov (United States)

The report contains general information on aluminium and aluminium compounds concerning the existing standards, emissions, exposure levels and effect levels. The document is to be considered as a first evaluation to be used for the national discussion dur...

1993-01-01

381

Estimation and characterization of PCDD/Fs and dioxin-like PCBs from Chinese iron foundries  

British Library Electronic Table of Contents (United Kingdom)

The iron foundry industry is considered to be a potential source of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). This study investigated the emission factors and total emission amounts of PCDD/Fs and dioxin-like polychlorinated biphenyls (DL-PCBs) from iron foundries in China. The concentrations and the World Health Organization toxicity equivalents (WHO-TEQs) are presented and the congener profiles are discussed in this paper. In the present work, 26 fly ash samples were collected and tested to quantify the PCDD/Fs and DL-PCBs generated by 14 plants of different scales, and five stack gas samples were collected from two (named as EFG and LFG) of those plants. The emission levels of PCDD/Fs and DL-PCBs indicated that hot-air cupolas had lower emissions than cold-air cupol...

2011-01-01

382

Energy concepts and the environment  

Energy Technology Data Exchange (ETDEWEB)

The paper discusses a number of recent studies investigating into the energy conservation and environmental impacts of electric heating systems (off-peak storage systems). In future, i.e. in and after 1993, off-peak storage systems will be evaluated through comparative analyses of oil-fired heating systems, pollutant emission analyses, the eventual success of pollution abatement measures designed for power plant emissions to keep within the legal limiting values, and the possible abandonment of pollution abatement measures abroad. Opposing the electric heating studies submitted by the electric power industry the author refutes their favourable results referring to the palliative selection of inadequate or vague parameters. Assuming average power plant pollutant emissions of 180 mg/standard/sup 3/ the nitrogen oxide emissions of oil-fired heating systems (134.1 kg/Tj) are found to be below those of ...

1988-03-01

383

Emissions, activity data, and emission factors of fluorinated greenhouse gases (F-Gases) in Germany 1995-2002  

Energy Technology Data Exchange (ETDEWEB)

Before the 1997 Kyoto Protocol on Climate Protection, the fluorinated greenhouse gases HFCs, PFCs, and SF6 (F-gases) aroused little public attention. Since then, the standards on surveying and reporting on national emissions have been rising constantly. Amongst others, the annual reporting to the UNFCCC secretariat makes detailed declarations on use and emissions of F-gases necessary, which have to be filled in specified formats for submission (Common Reporting Format = CRF). The scientific basis has been set out by the UNFCCC guidelines on reporting, in accordance with the instructions laid down in IPCC good practice guidance. Additionally, in Germany the Centralised System of Emissions (ZSE) shall provide a suitable tool to satisfy any quality needs of both activity data and emission factors. From 1995 onwards, activity data and emissions of each individual application sector ...

2005-06-15

384

Emissions Inventory Report Summary Reporting Requirements for the New Mexico Administrative Code, Title 20, Chapter 2, Part 73 (20 NMAC 2.73) for Calendar Year 1998  

Energy Technology Data Exchange (ETDEWEB)

Los Alamos National Laboratory (the Laboratory) is subject to emissions reporting requirements for regulated air contaminants under Title 20 of the New Mexico Administrative Code, Chapter 2, Part 73 (20 NMAC 2.73), Notice of Intent and Emissions Inventory Requirements. The Laboratory has the potential to emit 100 tons per year of suspended particulate matter, nitrogen oxides, carbon monoxide, sulfur oxides, and volatile organic compounds. For 1998, combustion products from the industrial sources contributed the greatest amount of criteria air pollutants from the Laboratory. Research and development activities contributed the greatest amount of volatile organic compounds. Emissions of beryllium and aluminum were reported for activities permitted under 20 NMAC 2.72 Construction Permits.

1999-09-01

385

Emission control cost-effectiveness of alternative-fuel vehicles  

Energy Technology Data Exchange (ETDEWEB)

Although various legislation and regulations have been adopted to promote the use of alternative-fuel vehicles for curbing urban air pollution problems, there is a lack of systematic comparisons of emission control cost-effectiveness among various alternative-fuel vehicle types. In this paper, life-cycle emission reductions and life-cycle costs were estimated for passenger cars fueled with methanol, ethanol, liquefied petroleum gas, compressed natural gas, and electricity. Vehicle emission estimates included both exhaust and evaporative emissions for air pollutants of hydrocarbon, carbon monoxide, nitrogen oxides, and air-toxic pollutants of benzene, formaldehyde, 1,3-butadiene, and acetaldehyde. Vehicle life-cycle cost estimates accounted for vehicle purchase prices, vehicle life, fuel costs, and vehicle maintenance costs. Emission control cost-effectiveness presented in dollars ...

1993-06-14

386

Electron detachment cross-sections and secondary-electron emission factors for heavy-negative-ion beams  

Energy Technology Data Exchange (ETDEWEB)

The properties of negative-ion beams are very important for designing negative-ion apparatus and applications of negative-ion beams, especially, electron detachment cross-sections at the interaction between negative-ion beams and gas particles in the transport system, and secondary-electron emission factors when negative ions are incident on solid surfaces. These properties of negative-ion beams were investigated experimentally as a function of the ion energy under 50 keV. The single electron detachment cross-sections are almost constant in the other of 10[sup -15] cm[sup 2] in this energy range, but double electron detachment cross-sections increase in proportion to the ion velocity and much smaller than the single one. As for the secondary-electron emission factor, the emission factors for negative-ion beam are found to be larger by 1 than those for positive-ion beams. (author).

1994-01-01

387

Electron detachment cross-sections and secondary-electron emission factors for heavy-negative-ion beams  

International Nuclear Information System (INIS)

The properties of negative-ion beams are very important for designing negative-ion apparatus and applications of negative-ion beams, especially, electron detachment cross-sections at the interaction between negative-ion beams and gas particles in the transport system, and secondary-electron emission factors when negative ions are incident on solid surfaces. These properties of negative-ion beams were investigated experimentally as a function of the ion energy under 50 keV. The single electron detachment cross-sections are almost constant in the other of 10"-"1"5 cm"2 in this energy range, but double electron detachment cross-sections increase in proportion to the ion velocity and much smaller than the single one. As for the secondary-electron emission factor, the emission factors for negative-ion beam are found to be larger by 1 than those for positive-ion beams. (author).

1994-01-01

388

Effect of injection pressure on heat release rate and emissions in CI engine using orange skin powder diesel solution  

British Library Electronic Table of Contents (United Kingdom)

Experiments have been conducted to study the effect of injection pressure on the combustion process and exhaust emissions of a direct injection diesel engine fueled with Orange Skin Powder Diesel Solution (OSPDS). Earlier investigation by the authors revealed that 30% OSPDS was optimum for better performance and emissions. In the present investigation the injection pressure was varied with 30% OSPDS and the combustion, performance and emissions characteristics were compared with those of diesel fuel. The different injection pressures studied were 215bar, 235bar and 255bar. The results showed that the cylinder pressure with 30% OSPDS at 235bar fuel injection pressure, was higher than that of diesel fuel as well as at other injection pressures. Similarly, the ignition delay was longer and wi...

2009-01-01

389

Diesel engine systems for underground coal mines  

Energy Technology Data Exchange (ETDEWEB)

This standard specifies requirements for the flameproofing and the limiting of surface temperature and exhaust emission control of diesel engine systems for use in underground coal mines.

1988-01-01

390

Deforestation Plays Critical Climate Change Role - NASA Earth ...  

Science.gov (United States)

May 11, 2007 ... "Deforestation in the tropics accounts for nearly 20 per cent of carbon emissions due to human activities," Dr. Canadell says. ...

391

Data structure for estimating emissions from non-road sources  

Energy Technology Data Exchange (ETDEWEB)

The work described in the following is a portion of the MEET project (Methodologies for Estimation Air Pollutant Emissions from Transport). The overall goal of the MEET project is to consolidate and present methodologies which can be used to estimate air pollutant emissions from various types of traffic sources. One of the goals of MEET is to provide methodologies to be used in the COMMUTE project also funded by DG VII. COMMUTE is developing computer software which can be used to provide emissions inventories on the European scale. Although COMMUTE is viewed as a prime user of the information generated in MEET, the MEET results are intended to be used in a broader area, and on both smaller and larger spatial scales. The methodologies and data presented will be useful for planners on a more local scale than a national or continental basis. While most attention in previous years has been concentrated on ...

1997-03-01

392

CBSD Version 2 Component Models of the IR Celestial ...  

Science.gov (United States)

... 1-sigma ZOHF pixel-to-plxel statistical fluctuations ... Spatial frequency filtering shows distinct bands, but miss ... LOS emissivity at the point of closest ...

1990-12-07

393

Agricultural intensification increases deforestation fire activity ...  

Science.gov (United States)

Fire-driven deforestation is the major source of carbon emissions from Amazonia. Recent expansion of mechanized agriculture in forested regions of Amazonia ...

394

Acquisition of a High Resolution Field Emission Scanning Electron Microscope for the Analysis of Returned Samples  

Science.gov (United States)

This grant furnished funds to purchase a state-of-the-art scanning electron microscope (SEM) to

2003-01-01

395

1 Title: Historic Emissions from Deforestation and Forest ...  

Science.gov (United States)

on the range of available deforestation, forest degradation, ... Results: Deforestation estimates showed good agreement for multi-year trends of increasing ...

396

Ultrasonography and Computerized Tomography in the diagnosis of complex abdominal lesions  

International Nuclear Information System (INIS)

Complex abdominal lesions include a variety of pathologies, such as septated, infected, and hemorrhagic cysts, abscesses, tumors, and fluid collections of different ethiology. These lesions present diagnostic difficulties with both Ultrasonography (US) and Computed Tomography (CT), since findings may not be present or, when present, are not specific. Keeping these limitations in mind, we evaluated 105 patients (111 abdominal lesions) with both US and CT in order to compare their adequacy in predicting the nature of the lesion. On the basis of US and CT results, complex abdominal lesions were divided in four classes: class I includes 43 cases in which both examinations gave the same contribution to the definition of the nature of the lesion, class II (14 lesions, mainly sperimentated cysts), in which US was superior to CT, class III includes 45 cases of hemorrhagic cysts, abscesses, fluid collections and, less frequently, cystic tumors; class IV includes 9 cases in ...

1988-01-01

397

The role of computed tomography in complex facial trauma  

Energy Technology Data Exchange (ETDEWEB)

Tridimensional localization of bone and soft tissue injuries in complex facial trauma is fundamental for treatment. The face can be conceptualized as 3 groups of interconnected osseous struts that are oriented in the horizontal, sagittal and coronal planes. Each group of struts is closely related to specific soft tissue structures that are susceptible to injury. Any single CT section in the coronal plane or in the axial plane contains parts of one or more these struts. Facial CT in biplane were performed in 32 patients of facial trauma. The most common site of facial fractures is found in middle part of horizontal struts, geometrically in anteromedial portion of the inferior orbital fissure of the face. The most common soft tissue injury combined with facial fracture is hematoma and/or herniated orbital contents into the maxillary sinus. The serious combined soft tissue injuries were ocular rupture, retroorbital hematoma and optic nerve injury resulting blindness. CT was superior to ...

1988-02-15

398

Sinonasal malignant tumors involvement of the orbit and skull: a computed tomography study  

International Nuclear Information System (INIS)

Malignant tumors of the sinonasal cavities are rare and often diagnosed late in the course of the disease. These tumors can extend into regions such as the orbit and brain, where treatment is difficult. Ten patients with non treated sinonasal malignant neoplasms and radiological evidence of tumor extension into the orbit and brain were studied with computed tomography. Five (50%) tumors were epithelial neoplasms whereas squamous cell carcinoma was the most common type (3 cases). The ethmoidal sinus was the most common site of origin of the tumors (40%), followed by the maxillary sinus (30%) and nasal cavity (30%). A total of 16 orbits were involved since 6 patients (60%) had bilateral orbital involvement. The tumors extended more often into the orbits through erosion of the medial and inferior orbital bones. All orbital compartments were involved in the majority of the orbits. Tumoral extension into the cranial cavity was more common through the ethmoidal (70%) and ...

2002-01-01

399

Reflection tomography using finite element method ray tracing  

Energy Technology Data Exchange (ETDEWEB)

The seismic reflection exploration technique which is one of the geophysical methods for oil exploration became effectively to image the subsurface structure with rapid development of computer. As a tool to perform seismic inversion, seismic forward modeling program using ray tracing should be developed. In this study, we have developed the algorithm that is to calculate the travel time of the complex geological structure using ray tracing by subdividing the geologic model into triangular element (finite element) having the constant velocity. We can analytically calculate Jacobian with some information by this current ray tracing. With this Jacobian, we will develop new algorithm which is to obtain geological properties and to image the subsurface. Since the FEM (Finite Element Method) ray tracing we have developed goes well the inverse velocities structure, we can apply the inversion problem to complex geological model. This report consists of 3 articles. 1) Development of 2-D ...

1996-12-01

400

Real-time cross-sectional averaged void fraction measurements in vertical annulus gas-liquid two-phase flow by neutron radiography and X-ray tomography techniques  

Energy Technology Data Exchange (ETDEWEB)

A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed Tomography (X-CT) system are used to determine the flow regime, the instantaneous cross-sectional averaged void fraction, and the time averaged void fraction in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements are obtained for gas flow rates form 0.0 to 30.0 l/min. The flow regimes observed by all three measurement systems via image analysis shows that the results agree well with each other. Both the RTNR and the X-CT systems show that the time averaged and cross-sectional averaged void fraction increases with increasing superficial gas velocity. Time and cross-sectional averaged void fractions determined by the RTNR system agree within 4% with those determined by the high speed X-ray CT technique. (orig.).

1995-03-11

401

Real-time cross-sectional averaged void fraction measurements in vertical annulus gas-liquid two-phase flow by neutron radiography and X-ray tomography techniques  

International Nuclear Information System (INIS)

A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed Tomography (X-CT) system are used to determine the flow regime, the instantaneous cross-sectional averaged void fraction, and the time averaged void fraction in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements are obtained for gas flow rates form 0.0 to 30.0 l/min. The flow regimes observed by all three measurement systems via image analysis shows that the results agree well with each other. Both the RTNR and the X-CT systems show that the time averaged and cross-sectional averaged void fraction increases with increasing superficial gas velocity. Time and cross-sectional averaged void fractions determined by the RTNR system agree within 4% with those determined by the high speed X-ray CT technique. (orig.).

1995-03-01

402

Improvement of FCR-linear tomography using digital image processing  

Energy Technology Data Exchange (ETDEWEB)

In order to improve the image quality of linear tomography performed with the Fuji Computed Radiography (FCR) system, we have examined one-dimensional unsharp mask filtering to reduce blur formed in the direction of tomographic swing. We determined a mask size and a weighting factor of the image processing suitable to obtain a quality tomogram. The mask size of 41 x 1 pixels for a 14 x 14'' imaging plate, which modifies the original image date and results in demonstrating a peak frequency at 0.2 cycles/mm for spatial frequency spectrum, is superior in showing fine vessel structures and morphological features of pathology in the lung fields. An additional spatial frequency filtration in the direction perpendicular to the tomographic movement reduces the blur and clearly demonstrates object contours running parallel to the tube movement. However, the additional filtration increases the appearance of noise on the processed image and offsets the ...

1994-02-01

403

High resolution computed tomography in the study of cervical spine trauma  

International Nuclear Information System (INIS)

Correct ortopedic therapy for traumas of the cervical rachis requires perfect knowledge of the spatial balance of the fracture focus. The authors belive Computed Tomography (CT) to be the most suitable, and often indispensable, method for this purpose. Twenty-four patients were examined for traumatic pathology of the cervical rachis. In 7 cases with clinically minor traumas, the negative outcome of the traditional traumas, the negative outcome of the traditional exam was considered reliable and sufficient for therapeutic purposes. The extant 17 patients were examined also by means of CT, either to better dermine the characteristics of skeletal lesions already ascertained with traditional techniques or to asses the presence of clinically-suspected osteo-articular lesions, even with negative conventional X-rays. For 9 of these patients orthopedic treatment was considered sufficient, whereas 8 patients underwent surgery and were subsequently examined with CT, which ...

1989-01-01

404

Ganglioneuromas in childhood: MRI and CT characteristics  

International Nuclear Information System (INIS)

Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a disseminated sprinkled pattern were seen in CT. In MRI T_1-weighted scans the tumors ...

2000-05-01

405

Focal lesions in external auditory canal: computed tomography images  

International Nuclear Information System (INIS)

To analyze and review the most common focal lesions of the external auditory canal (EAC), describing the computed tomography (CT) findings. The CT images of EAC were reviewed in a series of 167 patients. Abnormal findings were recorded in 13 cases. The CT images were correlated with otoscopic and/or intraoperative findings. There were four cases of osteoma (one located outside the EAC); all of which were treated surgically, as was the one case of exostosis. Six patients presented debris in EAC, coinciding with clinical evidence of external otitis. There were two cholesteatomas derived from EAC, one of them secondary to survery to treat osteoma. On patient was diagnosed as having a basal cell carcinoma of the ear, extending to EAC, but refused to undergo surgery. Five patients presented small triangular laminae of dense bone arising from the upper wall of the EAC which were defined as abnormal variants of the fusion of the temporal squamous epithelium to the ...

406

Exploring the mechanism of radiation-enhanced hepatocellular carcinoma cell invasion by swept source optical coherence tomography  

Science.gov (United States)

Ionizing radiation is a standard treatment for various human solid tumors. However, several clinical studies showed that a significant proportion of patients undergoing radiotherapy for hepatocellular carcinoma (HCC) develop intrahepatic and extrahepatic metastasis. Understanding of radiation-induced cancer cell invasiveness and behavior is essential and of great important for developing suitable treatment strategies to contain cancer spread. Therefore, in this study we evaluated the effectiveness of using swept source optical coherence tomography (SS-OCT) to monitor the enhancement of HCC cell invasiveness by radiation. SS-OCT images were acquired and recorded to obtain three-dimensional data sets per four hours in 48 hours after irradiating HepG2 cells with 7.5 Gy. The cell migration behavior in three-dimensional tissue models was quantified from images of radiation-induced and sham-irradiated cells.

2011-02-01

407

Digital image precessing for neutron television fluoroscopic system and its application to neutron computed tomography  

Energy Technology Data Exchange (ETDEWEB)

The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the reconstructed image. The image quality could be satisfactory to distinguish acrylic ...

1984-09-01

408

Digital image precessing for neutron television fluoroscopic system and its application to neutron computed tomography  

International Nuclear Information System (INIS)

The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the reconstructed image. The image quality could be satisfactory to distinguish acrylic ...

1984-01-01

409

Diagnostic possibilities following implantation of carbon-fibre-reinforced plastic (CFRP) total hip arthroplasty  

International Nuclear Information System (INIS)

Introduction: There are many problems in the radiological diagnosis of aseptic loosening in total hip arthroplasty. Computed tomography (CT) and magnetic resonance tomography (MRT) are not usable for metallic implants (stainless steel, cobalt alloy, titanium alloy). Material and Methods: From April 1993 to December 1993 15 CFRP non-cemented hip prostheses have been implanted. In a prospective clinical study plane radiographs, CT and MRT have been analysed. Results: Three stems were revised (1 femoral fracture, 1 severe thigh pain, 1 aseptic loosening). CFRP are not visible in plane radiographs. There was a complete (two-third of the cases) or nearly complete (one-third of the cases) small sclerotic interface between the prosthesis and the bone, these were apparent in CT and MRT in stable implant cases and did not have any clinical correlations. Discussion: The small sclerotic interface is quite different in comparison to so called 'Reactive ...

410

Diagnostic Performance of Computed Tomography Colonography in Symptomatic Patients and in Patients with Increased Risk for Colorectal Disease  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluate the diagnostic performance (colorectal lesions) of computed tomography (CT) colonography in 111 patients, a majority of whom were at high risk for colorectal neoplasia. Material and Methods: After bowel preparation, CT colonography was performed, immediately followed by conventional colonoscopy. The diagnostic performance of CT colonography was analyzed relative to lesion size, histological diagnosis, and diagnostic certainty. Results: The sensitivity of CT colonography increased with lesion size (P<0.001), and was 91% (21/23) for lesions > or = 10 mm. All 10 carcinomas and 86% (19/22) of adenomas > or = 5 mm were detected. Unconfirmed or false-positive CT findings were generally small and/or reported with low diagnostic certainty. The specificity of CT colonography would be 45% (30/66; 95% CI 34% to 57%) if patients with findings of any size and any diagnostic certainty were selected for follow-up, and 92% (85/92; 95% CI ...

2006-11-15

411

Cross-sectional void fraction distribution measurements in a vertical annulus two-phase flow by high speed X-ray computed tomography and real-time neutron radiography techniques  

Energy Technology Data Exchange (ETDEWEB)

A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed tomography (X-CT) system are compared for measurement of two-phase flow. Each system is used to determine the flow regime, and the void fraction distribution in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements obtained for gas flow rates from 0.0 to 30.01/min. The flow regimes observed by all three measurement systems through image analysis shows that the two-dimensional void fraction distribution can be obtained. The X-CT system is shown to have a superior temporal resolution capable of resolving the void fraction distribution in an (r,{theta}) plane in 33.0 ms. Void fraction distribution for bubbly flow and slug flow is determined.

1995-09-01

412

Cross-sectional void fraction distribution measurements in a vertical annulus two-phase flow by high speed X-ray computed tomography and real-time neutron radiography techniques  

International Nuclear Information System (INIS)

A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed tomography (X-CT) system are compared for measurement of two-phase flow. Each system is used to determine the flow regime, and the void fraction distribution in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements obtained for gas flow rates from 0.0 to 30.01/min. The flow regimes observed by all three measurement systems through image analysis shows that the two-dimensional void fraction distribution can be obtained. The X-CT system is shown to have a superior temporal resolution capable of resolving the void fraction distribution in an (r,#theta#) plane in 33.0 ms. Void fraction distribution for bubbly flow and slug flow is determined.

1995-09-01

413

Correctness of multi-detector-row computed tomography for diagnosing mechanical prosthetic heart valve disorders using operative findings as a gold standard  

Energy Technology Data Exchange (ETDEWEB)

The purpose was to compare the findings of multi-detector computed tomography (MDCT) in prosthetic valve disorders using the operative findings as a gold standard. In a 3-year period, we prospectively enrolled 25 patients with 31 prosthetic heart valves. MDCT and transthoracic echocardiography (TTE) were done to evaluate pannus formation, prosthetic valve dysfunction, suture loosening (paravalvular leak) and pseudoaneurysm formation. Patients indicated for surgery received an operation within 1 week. The MDCT findings were compared with the operative findings. One patient with a Bjoerk-Shiley valve could not be evaluated by MDCT due to a severe beam-hardening artifact; thus, the exclusion rate for MDCT was 3.2% (1/31). Prosthetic valve disorders were suspected in 12 patients by either MDCT or TTE. Six patients received an operation that included three redo aortic valve replacements, two redo mitral replacements and one Amplatzer ductal occluder occlusion of a ...

2009-04-15

414

Computer assisted axial tomography (Emi scan) in neurologic investigation  

Science.gov (United States)

Cerebral angiography, pneumoencephalography, and radioisotope brain scan with their differing diagnostic abilities have provided the neurologist and neurosurgeon with extremely valuable diagnostic techniques. It is doubtful, however, if any of these now conventional methods had the enormous impact on the practice of neurology that computer assisted axial tomography (C.A.T.) is beginning to have. Here, for the first time, is a test which, without significant risk or discomfort, can demonstrate some normal intracranial (and intraorbital) structures, can demonstrate some normal intracranial pathology and, in many cases, can make the potentially dangerous contrast studies unnecessary. After only a few months experience with C.A.T. in a clinical setting, it has become obvious that there will have to be a reappraisal of the accepted investigative work-up of many conditions. While it is too early to have formulated strict criteria for the use of C.A.T., this paper is an ...

1974-01-01

415

Computed tomography of the mediastinal tumor  

Energy Technology Data Exchange (ETDEWEB)

Forty-one cases of mediastinal tumor examined by computed tomography were reviewed. CT findings of the mediastinal malignancy were as follows: 1) inhomogeneous density on contrast CT, 2) equivocaton of fat plane surrounding the tumor, 3) irregular margin. Benign teratoma had smooth margin and included fat or calcification density. Mediastinal seminoma was observed as a lobulated mass with no calcification on CT. These findings were similar to the patterns of malignant thymoma or lymphoma. Consequently, it was very difficult to differentiate between malignant thymoma and malignant lymphoma by CT. According to our data, malignant thymoma tended to expand to only one side of the anterior mediastinum and to invade the anterior chest wall. On the other hand, malignant lymphoma of anterior medistinal type expanded into the trachea and the superior vena cava. In patients with sarcoidosis, the enlargement of bilateral hilar lymph nodes was commonly observed, on the ...

1984-12-01

416

Computed Tomography in staging and follow-up of thoracic Hodgkin's diseases  

International Nuclear Information System (INIS)

As yet, the role of Computed Tomography (CT) as a routine imaging technique in the staging and follow-up of thoracic Hodgkin's disease has not been assessed. The authors reported the results obtained in 120 patients affected with thoracic Hodgkin's disease, staged and followed by means af chest X-rays and CT. CT better identified intrathoracic involvement of mediastinal nodes, of lung parenchyma, of pleura, and of pericarcial and chest walls in 54/120 patients (45%), with staging modifications in 18 (15%) of them only. Treatment was changed only in 12 patients (19%) where radiation therapy had been planned. The clinical value of the additional information yielded by CT was especially evident in the follow-up: CT allowed the correct evaluation of persistent/ recurrent disease in 51/117 patients (43.5%), a figure high enough to suggest the use of CT in the routive follow-up of patients affected with thoracic Hodgkin's disease.

1990-01-01

417

Body weight-tailored contrast material injection protocol for 64-detector row computed tomography coronary angiography  

International Nuclear Information System (INIS)

The aim of this study was to assess the body weight-tailored contrast material injection protocol for 64-detector computed tomography (CT) to maintain optimal coronary CT attenuation. A total of 60 patients who underwent CT coronary angiography were assigned to one of three groups: protocol A, total of 0.7 ml kg"-"1 with 300 mg I/ml iodine concentration; protocol B, total of 0.6 ml kg"-"1 with 350 mg I/ml; protocol C, total of 0.7 ml kg"-"1 with 350 mg I/ml. The injection duration was 10 s in all patients. The proportion of intracoronary attenuation values >325 Hounsfield unit (HU) was compared on a per-vessel and per-patient basis. The attenuation value was significantly more likely to exceed 325 HU with protocol C (95% for reader 1 and 90% for reader 2) than with protocol A or B on the per-vessel analysis (P325 HU) with 64-detector CT when using an injection duration of 10 s. (author)

2011-01-01

418

Body dose conversion factors for computerized tomography  

International Nuclear Information System (INIS)

While there have been many experimental and calculational investigations on absorbed dose distribution in the patient resulting from conventional X-ray procedures, such data for computerized tomography (CT) are still sparse. As this diagnostic procedure has shown a rapid increase in application during recent years, we have determined absorbed dose to body organs in a human phantom resulting from CT examinations. The exposure model consists of the heterogeneous MIRD-5 phantom and a suitable Monte-Carlo method to calculate absorbed dose to organs of interest. The exposure conditions are specified according to the exposure specifications of a CT-scanner currently in use. The calculations cover the range of body tissues of interest in terms of organ absorbed doses as well as a risk weighted absorbed dose. A detailed example showing the calculation of red bone marrow dose is given and a somatic effective dose equivalent Hsub(ES) is calculated for different conventional ...

1980-10-31

419

Value of computed Tomography in re-staging patients undergoing second-look laparotomy for ovarian cancer  

International Nuclear Information System (INIS)

Twenty-five patients with ovarian carcinoma who had been operated and treated with chemotherapy underwent clinical examination and CT before reintervention (second-look laparotomy) to detect the presence of eventual recurrences. The prediction of recurrence based on CT and clinical findings was compared with the surgical findings at reintervention. CT proved to be more accurate than clinical examination in detecting recurrences; this was especially true for masses in the abdominal cavity, with the exception of small peritoneal nodules. The authors suggest the use of CT for staging the patients candidate to reintervention. This might help to avoid reintervantion in patients with persistent disease and to plan treatment.

1991-01-01

420

Technetium complexes as potential brain imaging agents  

International Nuclear Information System (INIS)

Single photon tomography using lipophilic tracers provides tomographic representations of regional blood flow. To penetrate a healthy blood-brain barrier requires that radiotracers either are fat-soluble or have an affinity for one of the selective blood-brain barrier transport systems. In recent years there has been an increasing interest to explore the ideal physical characteristics of "9"9"mTc for diagnostic problems of brain diseases. The development of radiopharmaceuticals for brain imaging including the intensively studied "9"9"mTc-propyleneamineoxime derivatives is discussed. (author).

421

Successful coil embolization of an unusual aorto-superior mesenteric vein fistula.  

Science.gov (United States)

The aortovenous fistulas are rare, most of them are aortocaval fistula. The non-caval communication of the fistula is sparse. Herein we report a 47-year-old female diagnosed as traumatic aorto-superior mesenteric vein (Ao-SMV) fistula. The abdominal pain, fullness, and frank bruit on abdominal auscultation suggested the diagnosis of an intra-abdominal arteriovenous fistula. The diagnosis of Ao-SMV was further confirmed by the computed tomography (CT) and aortography. The fistula was successfully treated with transcatheter coil embolization. This is the first case of Ao-SMV fistula. It provides an alternative option of treatment other than conventional surgery. PMID:19327940

2009-03-26

422

Spectrum of abdominal pathologies detected with CT in long term dialysis patients  

Energy Technology Data Exchange (ETDEWEB)

As a consequence of the expanded use of long term hemodialysis and continuous ambulatory peritoneal dialysis (CAPD) treatments and extended life spans, complications of end-stage renal disease and dialysis treatments are being encountered with increasing frequency in these patients. Computed tomography can accurately depict many of the potential complications of end-stage renal disease on dialysis. This article presents the abdominal CT findings of 429 end-stage renal disease patients who are on either hemodialysis or continuous ambulatory peritoneal dialysis treatment.

2009-11-15

423

Sonography and Computed Tomography in the evaluation of giant Baker's cysts  

International Nuclear Information System (INIS)

The US study of the posterior compartment of the knee usually allows the clinical suspicion of popliteal cyst to be confirmed. Neverthless, in case of giant Baker's cysts - which are, at any rate, less frequent -US diagnosis is more difficult. CT can help determine the benign nature of the lesion, and hallow an accurate spatial evaluation. Moreover CT, when accurately performed, demonstrates the caudal or cranial cystic spread, together with its clear separation from adjacent muscular tissues. Direct coronal scans are more useful to obtain better spatial definition than reformatted images.

1991-01-01

424

Roentgenological analysis of sternocostoclavicular hyperostosis by computed tomography  

Energy Technology Data Exchange (ETDEWEB)

Roentgenological analysis of the anterior chest wall was performed in twenty six patients with sternocostoclavicular hyperostosis. Initial hyperostotic change was seen at the first costosternal junction with ventral protrusion. Hyperostosis gradually developed around the first ribs, and irregular hyperostotic changes were also seen along the costoclavicular ligaments. Even in the final stage, however, sternoclavicular joint spaces were well preserved. These findings suggest that sternocostoclavicular hyperostosis is a disorder initiated around the costal cartilage including the periosteum and perichondrium, and that arthritis is not a condition stemming from that disorder.

1989-01-01

425

Rapid Tools for Joint Inversion and Imaging. Final report  

Energy Technology Data Exchange (ETDEWEB)

The activities and results of a Small Business Innovation Research Phase II project entitled ''Rapid Tools for Joint Inversion and Imaging'' are presented. Research and development on three-dimensional methods to recover distributions of material property values from sparse data are reported. Innovations using artificial neural networks and extended Kalman filtering are described. The report also covers investigations on upscaling and downscaling, segmentation for data processing, and applications to ground penetrating radar and geohydraulic tomography.

2000-08-02

426

Radiodiagnosis of Ewing's sarcoma of the rib in children  

International Nuclear Information System (INIS)

The results of the examination of 23 children with Ewing's sarcoma of the rib were analyzed: panoramic chest X-rays in 4 projections, spot radiographs of the robs, superexposed pictures, laterograms, urography, angiography, computerized tomography, and scanning of the skeleton. Causes of diagnostic errors made at the first consultation by a physician, were identified. Peculiarities of X-ray signs of tumors of this site in children were studied. Diagnostic difficulties in tumors complicated by pleurisy and in tumors of small sizes with extrapleural growth were shown. Inclusions in the extraoseous tumor component were noted in 8.7% of the cases.

427

New mass screening project for lung cancer with mobile spiral computed tomography (CT) and computed radiography (CR) in Ehime district  

Energy Technology Data Exchange (ETDEWEB)

To improve the detection rate of lung cancer, we have introduced low-dose CT and CR technique into a population-based annual mass screening. From December 1999, 3868 and 12618 individuals participated in this screening program with CT and with CR, respectively. Primary lung cancer was detected in 15 (0.39%) by CT and 8 (0.06%) by CR. This results show high detection rate of primary lung cancer as had been previously reported. (author)

2002-01-01

428

Involvement of the chest and abdominal wall as a rare manifestation in Hodgkin's disease  

Energy Technology Data Exchange (ETDEWEB)

Radiological findings of chest and abdominal wall involvement in Hodgkin's disease are reported. This manifestation was diagnosed in one patient in the primary staging and in two patients during the course of the disease. Typical radiological findings are soft tissue masses in the chest and abdominal wall, in two cases with continous tumor growth of enlarged mediastinal lymphnodes into the anterior chest wall. The axial computed tomography is the best method to evaluate the extent of chest and abdominal wall involvement in Hodgkin's disease.

1983-03-01

429

Hard X-ray phase imaging and tomography using a grating interferometer  

International Nuclear Information System (INIS)

An interferometric technique for hard X-rays is presented. It is based on two transmission gratings and a phase-stepping technique, and it provides separate radiographs of the phase and absorption profiles of bulk samples. Tomographic reconstruction yields quantitative three-dimensional maps of the X-ray refractive index and of the attenuation coefficient, with a spatial resolution down to a few microns. The method is mechanically robust, it requires little monochromaticity, and can be scaled up to large fields of view. These are important prerequisites for use with laboratory X-ray sources. Numerous applications ranging from wave front sensing to medical radiography are presently under investigation.

2007-07-01

430

Gunshot wounds of abdomen detected at CT. Personal experience in 30 patients; Ferite da arma da fuoco dell'addome studiate con tomografia computerizzata: esperienza personale in 30 casi  

Energy Technology Data Exchange (ETDEWEB)

The paper investigates the yield and the role of the computerized tomography in diagnosing abdominal gunshot wounds, with their rich and varied radiological signs and associated injuries, and subsequently used in the diagnosis. [Italian] Scopo del lavoro e' riportare l'esperienza personale nell'uso della tomografia computerizzata per riconoscere le lesioni da arma da fuoco dell'addome e nelle fasi successive dell'approfondimento diagnostico.

1999-09-01

431

Design of a neutron radiography collimator system in a through beam port at the TRIGA reactor  

Energy Technology Data Exchange (ETDEWEB)

A neutron collimator system is being designed as part of a neutron imaging facility for computed tomography and real-time neutron radiography research at the through beam port of the University of Texas TRIGA reactor. Lack of sufficient information about collimator systems in a through port from the literature necessitated the use of Monte Carlo calculations using the MCNP code 3 to search for optimal design configuration and materials that maximize the thermal neutron intensity at the image plane while minimizing the fast neutrons and gamma radiation.

1996-12-31

432

Computerized tomography in the diagnosis and follow up in three observations of primitive suprasellar germinoma  

International Nuclear Information System (INIS)

Three cases of primitive suprasellar germinomas are reported: the tumors show typical clinical signs (diabetes insipidus, disfunctions), but CT findings are not so specific. It is very important to reach a correct diagnosis based on clinical and radiological findings, because of very high radiosensibility of the tumor. The accuracy of preoparative diagnosis has been enhanced by CT in addition to conventional neuroradiological examinations. Due to the possible risk of meningeal spreading following biopsy, some authors prefer to avoid biopsy and to treat directly the patient by radiotherapy; a rapid reduction of the tumor size at the dose of 30 Gy suggest a possible germinoma.

1986-01-01

433

Computer tomographic demonstration of so-called azygos continuation in the absence of the hepatic segment of the inferior vena cava  

International Nuclear Information System (INIS)

Dilatation of the azygos vein is usually due to increased pressure or flow, rarely is it diopathic. Another cause is so-called continuation of the azygos in cases of absence of the hepatic segment of the inferior vena cava. The method of choice for the investigation of azygos dilatation nowadays is computer tomotgraphy. Anomalies of the inferior vena cava can be recognised in this way unequivocally by a non-invasive method. Computer tomography frequently shows important additional abnormalities (e.g. situs inversus, polysplenia), since it demonstrates all organs situated in the plane of section. (orig.).

434

Computed Tomography of the cranio-cervical junction in rhematoid arthritis  

International Nuclear Information System (INIS)

Twenty rheumatoid arthritis (RA) patients with involvement of the cranio-cervical junction (CCJ) were given CT scan. In most cases the myelo-CT technique with the lumbar injection of small quantities of non-ionic contrast medium was adopted; CT easily diagnosed the horizontal and vertical dislocations on the CCJ, the bone strcture lesions and the inflammatory masses. A high frequency of medullary compressions was also found in these patients. Myelo-CT appears to be the technique of choice for the precise definition of the various factors responsible for the neurological complications found in RA of the CCJ.

1987-01-01

435

Bilateral lipoma arborescens of the bicipitoradial bursa  

International Nuclear Information System (INIS)

A 37-year-old military mechanic presented to our institution with a chronic history of a slowly enlarging left elbow antecubital fossa mass. There was no history of other chronic illness or trauma. Magnetic resonance imaging (MRI) and excisional biopsy revealed fatty villi and synovial inflammation within the left bicipitoradial bursa, consistent with lipoma arborescens. Four years later the patient presented with a 6-month history of swelling at the antecubital fossa of the opposite elbow. Diagnostic computed tomography and MRI examinations were performed. The surgical and pathologic findings confirmed the imaging diagnosis of lipoma arborescens at the right bicipitoradial bursa. (orig.)

2002-11-01

436

Usefulness of Computed Tomography in pre-surgical evaluation of maxillo-facial pathology with rapid prototyping and surgical pre-planning by virtual reality  

International Nuclear Information System (INIS)

Purpose. To validate a protocol for creating virtual models to be used in the construction of solid prototypes useful for the planning-simulation of maxillo-facial surgery, in particular for very complex anatomical and pathologic problems. To optimize communications between the radiology, engineering and surgical laboratories. Methods and materials. We studied 16 patients with different clinical problems of the maxillo-facial district. Exams were performed with multidetector computed tomography (MDCT) and single slice computed tomography (SDCT) with axial scans and collimation of 0.5-2 mm, and reconstruction interval of 1 mm. Subsequently we performed 2D multiplanar reconstructions and 3D volume-rendering reconstructions. We exported the DICOM images to the engineering laboratory, to recognize and isolate the bony structures by software. With these data the solid prototypes were generated using stereolitography. To date, surgery has been ...

2005-11-01

437

Reflection tomography using finite element method ray tracing  

Energy Technology Data Exchange (ETDEWEB)

The seismic reflection exploration technique which is one of the geophysical methods for oil exploration became effectively to image the subsurface structure with rapid development of computer. As a tool to perform seismic inversion, seismic forward modeling program using ray tracing should be developed. In this study, we have developed the algorithm that is to calculate the travel time of the complex geological structure using ray tracing by subdividing the geologic model into triangular element (finite element) having the constant velocity. We can analytically calculate Jacobian with some information by this current ray tracing. With this Jacobian, we will develop new algorithm which is to obtain geological properties and to image the subsurface. After subdividing subsurface into triangular element we shoot off the ray into subsurface by the Snell`s law. And then after taking the ray path which is similar to proper assumption we can calculate travel time. With this new ray tracing ...

1996-12-01

438

Neutron-computer tomography using real-time neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

A real-time neutron radiography facility was constructed including the capability of neutron tomography. The neutron beam was measured for total neutron flux ((1.0 +/- 0.2) x 10/sup 11/ m/(m/sup 2/-sec)), gold cadmium ratio (52 +/- 3) and effective neutron temperature (83/sup 0/C +/- 8/sup 0/C). The angular divergence or nonparallelism of the neutron beam was measured to be 2.3/sup 0/ +/- 0.1/sup 0/ thereby providing a means of quantifying the collimator effectiveness. The resolution capabilities of both static film and real-time neutron radiographs were quantified using a Fourier transform algorithm to calculate the modulation transfer function of both types of radiographs. The contrast sensitivity of both types of radiographs. The contrast sensitivity of both types of radiographs was measured as 3.1% for film and 4.0% for real-time radiographs. Two tomography algorithms, the simultaneous iterative reconstruction technique (SIRT) and the ...

1986-01-01

439

Neutron-computer tomography using real-time neutron radiography  

International Nuclear Information System (INIS)

A real-time neutron radiography facility was constructed including the capability of neutron tomography. The neutron beam was measured for total neutron flux ((1.0 +/- 0.2) x 10"1"1 m/(m"2-sec)), gold cadmium ratio (52 +/- 3) and effective neutron temperature (83"0C +/- 8"0C). The angular divergence or nonparallelism of the neutron beam was measured to be 2.3"0 +/- 0.1"0 thereby providing a means of quantifying the collimator effectiveness. The resolution capabilities of both static film and real-time neutron radiographs were quantified using a Fourier transform algorithm to calculate the modulation transfer function of both types of radiographs. The contrast sensitivity of both types of radiographs. The contrast sensitivity of both types of radiographs was measured as 3.1% for film and 4.0% for real-time radiographs. Two tomography algorithms, the simultaneous iterative reconstruction technique (SIRT) and the convolution method, were ...

1986-01-01

440

Computerized tomography-guided neurolytic splanchnic nerve block  

International Nuclear Information System (INIS)

Computerized tomography-guided neurolytic splanchnic nerve block is a technique for relieving abdominal cancer pain; the goal is the alcoholic neurolytic interruption of the sensitive structures in retroperitoneal space. Computerized tomography yields accurate anatomical detailing and the course for needle placement and alcohol spread. January, 1993, to July, 1996, twenty-one bilateral splanchnic nerve blocks were performed through the posterior access. Forty-eight hours after alcoholism. 14 patients (66%) had complete pain regression; 52% of the patients needed no analgesics for 6 to 54 days and only 9 patients (42%) needed another low opioid therapy. Complications included hypotension and diarrhea in all cases. One had a cardiac arrest and diet 8 days after the procedure. There were no other complications. The whole procedure usually lasted 60 min (range: 45 to 90 min). Splanchnic nerve neurolysis is a useful treatment in the patients with ...

1997-01-01

441

Computerized Tomography-guided fine-needle biopsy of peripheral pulmonary nodules < 2 cm in diameter  

International Nuclear Information System (INIS)

The authors investigated the role of Computerized Tomography in guiding fine needle biopsy (FNB) in small (2 2 cm in diameter for CT-guided FNB sensitivity, specificity and diagnostic accuracy. Cytologic specimens were positive for malignancy in 40/52 cases (76.9%) and negative in 12 (23.1%). Clinical-surgical follow-up confirmed all the positive cytologic findings (40 cases), while 2 of the extant 12 cases were false negatives (95.20% sensitivity, 100% specificity and 96.15% diagnostic accuracy). 158 of 195 nodules > 2 cm in diameter and with clinical surgical follow-up (81.3%) were positive for malignancy and 34 were negative (17.43%) (98.75% sensitivity, 97.14% specificity and 98.46% diagnostic accuracy). Pneumothorax occurred in 33 patients (16.5%) with nodules > 2 cm in diameter as a complication of biopsy. Hemoptysis occurred in 15 patients (7.5%). In the whole group of lung lesions, the complications were pneumothorax in 80 patients (4.1%), hemoptysis ...

442

The waste problem - an inevitable consequence of energy consumption. Abfallproblematik - eine unabwendbare Folge des Energieeinsatzes  

Energy Technology Data Exchange (ETDEWEB)

'Within 15 years the energy consumption bottleneck has shifted from the supply side to emissions, i.e. to the waste side.' Reflecting this statement one may realize the importance of lending more weight to energy conservation but may also be induced to critically analyze the corresponding measures. First results of such reflections are given with regard to the payback periods of air pollution abatement measures relative to the additional emissions they cause. (orig.).

1991-12-18

443

Symposium on wood fuel and air purification. Symposium Brennstoff Holz und Luftreinhaltung  

Energy Technology Data Exchange (ETDEWEB)

Lectures were held on forest and wood management, the forest as an energy source and the emission problem of wood combustion, future emission limitating regulations for wood firing, influence of firing technique on air pollution abatement and constructive and operational air pollution abatement measures with manually and continuously fuelled furnaces.

1981-01-01

444

Study of emission of Cerenkov radiation by tachyons  

Energy Technology Data Exchange (ETDEWEB)

The emission of Cerenkov radiation by tachyons has been examined by using the reduced expansions of superluminal electromagnetic fields in terms of standard helicity representation of Poincare group. It has been shown that the tachyons emit Cerenkov radiation through their coupling only with subluminal electromagnetic fields and that a charged tachyon can emit Cerenkov radiation only in the media in which it travels with a velocity lower than that of light while in the usual medium in which its velocity is more than that of light, it will never emit Cerenkov radiation.

1983-01-01

445

Spontaneous radiation emission during penetration of ions in solids  

International Nuclear Information System (INIS)

In this work, the principal continuum radiative emission processes, which occur during the penetration of ions in solids or gases, are resumed. The characteristics of the following processes are discussed: secondary electron bremsstrahlung (SEB), atomic bremsstrahlung (AB), and internuclear bremsstrahlung (INB). Recent advances of the ion channeling effects in crystal solids on the spontaneous radiative spectra are exposed. (A.C.A.S.).

1988-09-25

446

Reply to comments on the proposed on-road vehicle and engine emission regulations  

Energy Technology Data Exchange (ETDEWEB)

In February 2001, the Minister of Environment Canada outlined a series of measures to be implemented over the next decades to reduce emissions from vehicles, engines and fuels. The agenda includes the development of new regulations under the authority of Part 7, Division 5 of the Canadian Environmental Protection Act (CEPA) to align Canada's emission standards for on-road vehicles with those of the United States Environmental Protection Agency. This paper presents a detailed summary of comments received by the interested parties that appeared at a public consultation in November 2001 to discuss and raise issues about the proposed regulations. The parties that provided submissions included: governments; the vehicle and engine manufacturing industry; the oil industry; other groups of associations such as the Canadian Trucking Alliance, David Suzuki Foundation, and West Coast Environmental Law; and, five private individuals. The report ...

2002-12-01

447

Reevaluation of the average prompt neutron emission multiplicity (nubar) values from fission of uranium and transuranium nuclides  

Science.gov (United States)

In response to a need of the safeguards community, we have begun an evaluation effort to upgrade the recommended values of the prompt neutron emission multiplicity distribution, P/sub nu/ and its average value, nubar. This paper will report on progress achieved thus far. The evaluation of the uranium, plutonium, americium and curium nuclide's nubar values will be presented. The recommended values will be given and discussed. 61 references.

1984-01-01

448

Nonlinear air-coupled emission: The signature to reveal and image microdamage in solid materials  

International Nuclear Information System (INIS)

It is shown that low-frequency elastic vibrations of near-surface planar defects cause high-frequency ultrasonic radiation in surrounding air. The frequency conversion mechanism is concerned with contact nonlinearity of the defect vibrations and provides efficient generation of air-coupled higher-order ultraharmonics, ultrasubharmonics, and combination frequencies. The nonlinear air-coupled ultrasonic emission is applied for location and high-resolution imaging of damage-induced defects in a variety of solid materials.

2007-12-17

449

NO{sub x} emissions of a jet diffusion flame which is surrounded by a shroud of combustion air  

Energy Technology Data Exchange (ETDEWEB)

The present work reports an experimental study on the behavior of a jet flame surrounded by a shroud of combustion air. Measurements focussed on the flame length and the emissions of NO{sub x}, total unburned hydrocarbons, CO{sub 2}, and O{sub 2}. Four different fuel flow rates (40.0, 78.33, 138.33, and 166.6 cm/s), air flow rates up to 2500 cm{sup 3}/s and four different air injector diameters (0.079 cm, 0. 158 cm, 0.237 cm, and 0.316 cm) were used. The shroud of combustion air causes the flame length to decrease by a factor proportional to 1/[p{sub a}/p{sub f} + C{sub 2}({mu}{sub a}Re,a/{mu}{sub f}Re,f){sup 2}]{sup {1/2}}. A substantial shortening of the flame length occurred by increasing the air injection velocity keeping fuel rate fixed or conversely by lowering the fuel flow rate keeping air flow rate constant. NO{sub x} emissions ranging from 5 ppm to 64 ppm were observed and the emission of NO{sub x} decreased ...

1996-08-01

450

Modeling the effects of changes in New Source Review on national SO{sub 2} and NOx emissions from electricity-generating units  

Energy Technology Data Exchange (ETDEWEB)

The Clean Air Act establishes New Source Review (NSR) programs that apply to the construction or modification of major stationary emissions sources. In 2002 and 2003, the U.S. Environmental Protection Agency revised its rules to narrow the applicability of NSR to facility renovations. Congress then mandated a National Research Council study of the effects of the rules. An electricity-sector model - the Integrated Planning Model (IPM) - was used to explore the possible effects of the equipment replacement provision (ERP), the principal NSR change that was to affect the power-generation industry. The studies focused in particular on coal-fired electricity generating units, EGUs, for two reasons. First, coal-fired EGUs are important contributors of these pollutants, accounting for approximately 70 and 20% of nations SO{sub 2} and NOx emissions in 2004, respectively. Second, the shares of total capacity of large coal-fired EGUs that lack flue-gas ...

2007-03-15

451

Intensity of auger-emission of silicon from binary compounds in the ion auger spectroscopy  

International Nuclear Information System (INIS)

Auger-electron emission from different silicides has been studied for 4 and 10 keV Ar ion excitation. The intensity of the SiLMM Auger line changes significantly with channing concentration and atomic number of the metal-parthner. The experimental results can be explained in terms of a simple model based on the probability of Si-Si collision symmetric cascade in these binary compounds.

452

Emissions to air in Sweden of sulphur dioxide, nitrogen oxides and carbon dioxide in 1995; Utslaepp till luft i Sverige av svaveldioxid, kvaeveoxider och koldioxid, 1995  

Energy Technology Data Exchange (ETDEWEB)

In this report statistical data are presented on a national level on emissions to air in Sweden in 1995 of sulphur dioxide (SO{sub 2}), nitrogen oxides (NO{sub x}, counted as NO{sub 2}) and carbon dioxide (CO{sub 2}). Corresponding data for 1980 and 1994 are presented as a comparison. For CO{sub 2} data for 1990 and 1994 are presented as a comparison. The total amount of SO{sub 2}-emissions to air in 1995 were 94 000 tons, which means a decrease by 3 percent since 1994. The total amount of NO{sub x}-emissions to air were 362 000 tons, a 3 percent decrease since 1993. The total amount of CO{sub 2}-emissions to air were 63 200 000 tons, an increase by 7 percent compared with 1990. Differentiated data are given for various sources of emissions, i.e. combustion of fuels, industrial processes and mobile sources. Further data are presented on emission of SO{sub 2} and ...

1996-12-01

453

Effect of injection pressure on heat release rate and emissions in CI engine using orange skin powder diesel solution  

International Nuclear Information System (INIS)

Experiments have been conducted to study the effect of injection pressure on the combustion process and exhaust emissions of a direct injection diesel engine fueled with Orange Skin Powder Diesel Solution (OSPDS). Earlier investigation by the authors revealed that 30% OSPDS was optimum for better performance and emissions. In the present investigation the injection pressure was varied with 30% OSPDS and the combustion, performance and emissions characteristics were compared with those of diesel fuel. The different injection pressures studied were 215 bar, 235 bar and 255 bar. The results showed that the cylinder pressure with 30% OSPDS at 235 bar fuel injection pressure, was higher than that of diesel fuel as well as at other injection pressures. Similarly, the ignition delay was longer and with shorter combustion duration with 30% OSPDS at 235 bar injection pressure. The brake thermal efficiency was better at 235 bar than ...

2009-04-01

454

Development of vehicle exhaust gas emissions. A balance of the effects of regulations ratified by the European Communities and of tax credits for low emission automobiles. A study on behalf of the Northrhine-Westphalian Ministry for Town Planning, Housing and Transportation. Die Entwicklungen der Schadstoffemissionen aus dem Kfz-Verkehr. Eine Bilanz der Auswirkungen der EG-Beschluesse und der steuerlichen Anreize zum schadstoffarmen Pkw. Studie im Auftrag des Ministers fuer Stadtentwicklung, Wohnen und Verkehr des Landes Nordrhein-Westfalen  

Energy Technology Data Exchange (ETDEWEB)

Due to the 'novel forest diseases' the political parties of the Federal Republic of Germany unanimously attend to the reduction of emissions. The transportation sector is considered to be a major emission source. A study discussed in the publication abstracted did therefore aim at giving a detailed account and description of the recently ratified technical requirements and tax credits expected to reduce vehicle exhaust gas air pollution. Moreover, the study researches into the regulations' importance as to the low emission properties of individual automobiles. Based on the results obtained the study arrives at assumptions as to emissions to be expected from the transportation sector. It tries to assess the financial import with respect to the individual citizen, overall internal revenues and federal motor vehicle taxes. The introductory chapter is followed by a review of ...

1985-01-01

455

Details about emission sources for IMF's in heavy ion collisions  

International Nuclear Information System (INIS)

A large IMF- and event characterizing multidetector system (CHICSI) is under development for storage ring experiments. In ''test'' experiments with telescopes of CHICSI type the IMF production has been measured for "1"4N induced reactions at 14A and 32A MeV. Detailed information about the emission sources, particularly from the IMF yield in reactions with isotope separated targets and from isobaric yield ratios in the sub-Coulomb region is discussed. (orig.).

1994-01-17

456

Cost and CO2-Emission Reduction of Biomass Cascading. Methodological Aspects and Case Study of SRF Poplar  

Energy Technology Data Exchange (ETDEWEB)

This study presents and applies a coherent methodological framework to compare biomass cascading chains, i.e. the subsequent use of biomass for materials, recycling and energy recovery, considering land use, CO2 emission reduction and economic performance. Example cascading chains of short rotation poplar wood are compared with each other on the basis of literature data. Results for these chains vary strongly, namely, from CO2 mitigation benefits of 200 euro/Mg CO2 to CO2 mitigation costs of 2200 euro/Mg CO2, and from net CO2 emission reductions per hectare of biomass production of 28 Mg CO2/(ha yr) to net CO2 emissions of 8 Mg CO2/(ha yr). Using a present-value approach to determine CO2 emissions and costs affects the performance of long-term cascading chains significantly, i.e. cost and CO2 emission reduction are decreased. In general, cascading has the potential to improve both ...

2005-08-01

457

Continuous emission monitoring -- Data acquisition and handling system for management  

Energy Technology Data Exchange (ETDEWEB)

This paper describes New York State Electric and Gas Corporation`s concept for a comprehensive, centrally located data system for management of their continuous emission monitoring systems (CEMS) data. The topics of the paper include the power system`s mix of generating units; data reporting requirements; data base management; nitrogen oxides compliance tracking; sulfur dioxide, nitrogen oxides, carbon dioxide and flow monitoring; and allowance tracking.

1995-09-01

458

Comprehensive, nonintercepting electron-beam diagnostics using spontaneous emission  

Energy Technology Data Exchange (ETDEWEB)

Characterization and optimization of electron-beam parameters are important aspects of optimizing free-electron laser (FEL) performance. The visible spontaneous emission ({lambda}{approximately}650 nm) from the 5-meter long undulator of the Boeing FEL experiment can be characterized in sufficient detail with a streak/spectrometer to deduce time-resolved electron-beam spatial position and profile, micropulse duration, and energy. 7 refs., 13 figs., 2 tabs.

1989-01-01

459

Combined cycles and combined energy systems for a safe and sound environment and life  

Energy Technology Data Exchange (ETDEWEB)

Discussion is presented of world CO{sub 2} emissions and the effect rising population and population distribution has on this. Possible ways of decreasing emissions are presented, including potential for heat recovery, exhaust-air purification as an energy supply, shared power supply in industry, the use of cogeneration, and multiple use of heat in industry. 9 refs., 10 figs., 3 tabs.

1992-01-01

460

Cloud computing: A silver lining for climate change? - Climate Action Programme  

Wastenet

... - Climate Action Programme cloud computing, climaet change, carbon emissions, verdantix, cloud, it, computer cloud computing, climaet change, carbon emissions,...verdantix, cloud, it, computer GreenMedia.com AidForumOnline.org ClimateActionProgramme.org Search Climate Action... In partnership with the United Nations ...

461

Calculation of atomic spontaneous emission rate in 1D finite photonic crystal with defects  

CERN Document Server

We derive the expression for spontaneous emission rate in finite one-dimensional photonic crystal with arbitrary defects using the effective resonator model to describe electromagnetic field distributions in the structure. We obtain explicit formulas for contributions of different types of modes, i.e. radiation, substrate and guided modes. Formal calculations are illustrated with a few numerical examples, which demonstrate that the application of effective resonator model simplifies interpretation of results.

2009-01-01

462

Application of an on-line measurement system for HF emission control (2. part); Application d'un systeme de mesure en ligne pour le controle des emissions de fluor (2. partie)  

Energy Technology Data Exchange (ETDEWEB)

In the last issue of 'L'Industrie ceramique et verriere', we presented the first part of this study. We describe in this issue the experimental procedure, the results and the conclusions of this work. (authors)

2005-02-01

463

A study of the Baldwin effect in the IUE data set  

Science.gov (United States)

The paper investigates the controversial relation between the continuum luminosity and the C IV 1550 emission-line strength in the spectra of quasars, commonly referred to as the Baldwin effect, as a possible indicator of absolute luminosity. It is concluded that the Baldwin effect does represent a physical correlation between the continuum and the C IV 1550 equivalent width rather than a consequence of selection effects. In addition to the C IV results, a similar relation is found for the Lyman-alpha emission line. 38 refs.

1990-07-01

464

A review of initiatives to reduce energy-related CO_2 emissions from the city of Oxford: past, present and future  

International Nuclear Information System (INIS)

This paper reviews three key initiatives undertaken in the historical city of Oxford to bring about reductions in energy-related CO_2 emissions on a city-wide scale. The author has been part of all the three initiatives. In 2002, a collaborative partnership between academia, industry and city council started the Oxford Solar Initiative (OSI) which uses a community-based approach to help households and organisations in Oxford, financially and technically, to install solar energy systems and energy efficiency measures in buildings. So far OSI has facilitated the installation of 80 active solar systems, over 450 energy efficiency measures and 3,000 low energy bulbs. The scientific basis of OSI is a GIS-based DECoRuM model which estimates and maps baseline energy use and CO_2 emissions on a house-by house level, identifies 'pollution' hotspots, predicts the potential for reductions in CO_2 emissions and monitors reductions ...

2007-06-04

465

A multi-megawatt X-band solid state microwave switch  

Energy Technology Data Exchange (ETDEWEB)

The authors present design methodology and initial experimental results for a high power microwave switch. The switch is designed for application to the pulse compression system associated with the Next Linear Collider Test Accelerator (NLCTA). The switch is based on the excitation of a plasma layer within a silicon wafer by either a laser or an electron beam. They investigate problems associated with high power operation of such a switch. They explore solutions to the problems of thermal runaway, avalanche breakdown, photo-emission, and secondary emission.

1995-12-31

466

A critical review of the hypothesis that climate change is caused by carbon dioxide  

Energy Technology Data Exchange (ETDEWEB)

This critical review with 28 references examines absorption and emission in the v2 band of the carbon dioxide molecule at around the 15micron wavelength. The argument for additional infrared absorption, the enhanced greenhouse effect due to increased carbon dioxide concentrations, and radiation transport and increased emissions are discussed. Experiments studying the transmission spectra of pure carbon dioxide and carbon dioxide in nitrogen, and comparing them with the results of climate modelling using the HITRAN and GEISA databases, are described.

2000-07-01

467

Volatile Organic Compound Formation in Waste Composting Processes  

Environmental Research Database

Objectives~%~ To quantify the volatile organic compound (VOC) emissions arising from the composting of a range of municipal and~%~ industrial wastes.~%~~%~ To relate the VOC emissions to the material being processed and the process conditions.~%~~%~ To confirm the findings of the above activites by monitoring full-scale composting operations.~%~~%~ To develop predictive models of VOC emissions in relation to waste feedstock and process conditions.~%~~%~ To produce guidance for plant designers, operators a [continued...]DescriptionA recent study of three composting plants undertaken for the Environment Agency has confirmed earlier work suggesting that waste composting can be a source of volatile organic compound (VOC) emissions. However, these experiments were restricted to garden and kitchen waste composting schemes and it was not ...

2005-01-30

468

Survey of implementation plan constructed for `the New Earth 21 Project`; Chikyu saisei keikaku no jisshi keikaku sakusei ni kansuru chosa jigyo  

Energy Technology Data Exchange (ETDEWEB)

It is necessary to establish scenarios for reducing CO2 emissions and for developing CO2 emission control technologies to obtain a global consensus, using appropriate analytical models. For modification of the DNE-21 (Dynamic New Earth 21) model, it has a category designated as innovative technologies not involving CO2 emission and an optional consideration for the absorption of atmospheric CO2 by biomass. A global carbon circulation model, including vegetation in its scope, is also incorporated. Major results of the simulation are shown. When 20% reduction in CO2 emissions is required for only OECD countries after the year 2020, it has been demonstrated that CO2 concentration in the atmosphere will reach as high as about 900 ppm in 2100 due to CO2 emission by developing countries, and will not be a tolerable level. Under the condition that CO2 concentration in the atmosphere is ...

1997-03-01

469

Study of the Smith-Purcell effect in the relativistic regime  

International Nuclear Information System (INIS)

We propose to investigate the spontaneous emission of radiation arising out of the interaction of a relativistic electron beam with a metallic grating (the Smith-Purcell effect). The work will concentrate, primarily, in the 50-120 #mu#m part of the infrared spectrum and will be an extension of the work begun by the Oxford-Dartmouth-Essex collaboration; one of the early objectives of the project will be to develop a quantitative understanding of the power spectrum of the emitted radiation over a wide range of emission angles. In particular, the limits of relativistic peaking of forward directed emission will be investigated. The electron beam will be produced by laser irradiation of a metallic cathode in the terminal of a small Van de Graff accelerator located in the Technische Universitaet, Muenchen. Beam energies will be in the range of 2 - 4 MeV. Initial tests on photoproduction of electrons have yielded 10 mA pulses with ...

1995-08-21

470

Performance and exhaust emissions in a natural-gas fueled dual-fuel engine; Tennen gas dual fuel kikan no seino oyobi haiki tokusei  

Energy Technology Data Exchange (ETDEWEB)

In order to establish the optimum fueling in a natural gas fueled dual fuel engine, tests were made for some operational parameters and their combination on the engine performances and the exhaust emissions. The results show that the gas oil quantity should be increased and gas oil injection timing should be advanced to suppress unburned hydrocarbon emission at middle and low output range, while the quantity should be reduced and the timing should be retarded to avoid onset of knock at high loads. The unburned hydrocarbon emission and the thermal efficiency are improved at the same load avoiding too lean natural gas premixture by restriction of intake charge air. However the improvement is limited because the ignition and initial combustion of pilot diesel fuel is deteriorated when the cylinder pressure is excessively lowered by throttling. The increase in pilot gas oil amount is effective for low-load operation and the ...

2000-07-25

471

Nonthermal emission from the radio relic of the galaxy cluster A2256  

CERN Document Server

We aim to obtain a consistent description of non-thermal emissions from Abell 2256 and to give a prediction for a gamma-ray emission from this galaxy cluster. Assuming that a radio relic illuminates a localization of an ongoing merger, and that both radio and non-thermal part of hard X-ray emission are due to electron component of cosmic rays filling the relic, we derived from radio and hard X-ray properties of the relic in A2256 the magnetic field strength and number densities for relativistic electrons and protons. Due to the interpretation of the radio relic as a structure formed just where a shock front is, we discuss a gamma-ray emission at the cluster periphery. The estimated strength of the magnetic field in the relic is equal to 0.05 \\muG, while the amplitude of the electron number density varies from 3 x 10^{-4} to 3 x 10^{-5} cm^{-3} (respectively for the relic thickness of 50 to 500 kpc). We ...

2011-01-01

472

New constraints on the primordial black hole number density from Galactic gamma-ray astronomy  

CERN Document Server

Primordial black holes are unique probes of cosmology, general relativity, quantum gravity and non standard particle physics. They can be considered as the ultimate particle accelerator in their last (explosive) moments since they are supposed to reach, very briefly, the Planck temperature. Upper limits on the primordial black hole number density of mass $M_{\\star} = 5 10^{14}$ g, the Hawking mass (born in the big-bang terminating their life presently), is determined comparing their predicted cumulative $\\gamma$-ray emission, galaxy-wise, to the one observed by the EGRET satellite, once corrected for non thermal $\\gamma$-ray background emission induced by cosmic ray protons and electrons interacting with light and matter in the Milky Way. A model with free gas emissivities is used to map the Galaxy in the 100 MeV photon range, where the peak of the primordial black hole emission is expected. The best ...

2009-01-01

473

Model-based control strategy for direct injection diesel engine; Model enzan ni motozuku chokufun diesel engine no seigyo saitekika  

Energy Technology Data Exchange (ETDEWEB)

For a direct injection diesel engine to exhibit its inherent low-emission characteristics, it is essential to improve control accuracy, in particular under transient operating conditions during which emissions are more noted. A model-based control system is established for exhaust gas recirculation (EGR) and air/fuel ratio, using a diesel-engine/vehicle model established on the CAD control system. Described herein are the results of simulation for optimizing control of transient conditions, and the emission-controlling effects confirmed by the field tests. The tests for verification of the established model have confirmed that there are good agreements between the simulated and observed results in terms of air/fuel ratio changing with EGR ratio, exhaust and intake gas and pressure levels, and vehicle speed. The model will be applicable to assessment of emission characteristics under varying conditions. ...

1997-05-01

474

Mercury balance analysis; Massestroemsanalyse for kviksoelv  

Energy Technology Data Exchange (ETDEWEB)

A detailed assessment of the consumption of mercury, divided into use areas, was carried out. Disposal and emissions to the environment were also qualified. The assessment is mainly based on data from 1992 - 1993. The most important source of emission of mercury to air is solid waste incineration which is assessed in particular to be due to the supply of mercury in batteries (most likely mercury oxide batteries from photo equipment) and to dental fillings. The second most important source of mercury emission to air is coal-fired power plants which are estimated to account for 200-500 kg of mercury emission p.a. Other mercury emissions are mainly related to waste treatment and disposal. The consumption of mercury is generally decreasing. During the period from 1982/83 - 1992-93, the total consumption of mercury in Denmark was about halved. This development is related to the fact that ...

1996-08-01

475

Hydrogen combustion and exhaust emissions in a supercharged gas engine ignited with micro pilot diesel fuel  

International Nuclear Information System (INIS)

A hydrogen combustion and exhaust emissions in a supercharged gas engine ignited with micro pilot diesel fuel was discussed in this presentation. A schematic diagram of the experimental study was first presented. The single cylinder, water-cooled, supercharged test engine was illustrated. Results were presented for the following: fuel energy and energy share (hydrogen and diesel fuel); pressure history and rate of heat release; engine performance and exhaust emissions; effect of nitrogen dilution on heat value per cycle; effect of N_2 dilution on pressure history and rate of heat release; and engine performance and exhaust emissions. This presentation demonstrated that smooth and knock-free engine operation results from the use of hydrogen in a supercharged dual-fuel engine for leaner fuel-air equivalence ratios maintaining high thermal efficiency. It was possible to attain mor3 than 90 per cent hydrogen-energy substitution ...

2009-09-20

476

Historical on the Norm Related to the CO{sub 2} Emission Integrated in the Protocol of Kyoto; Historico sobre la Normativa Relacionada con las Emisiones de CO{sub 2} Integrado en el Protocolo de Kyoto  

Energy Technology Data Exchange (ETDEWEB)

The United Nations Framework Convention on Climate Change (UNFCCC) was approved in 1992 to respond to the worl-wide concern about the warming of the planet. The primary target was the stabilization of the concentration of greenhouse gases in the atmosphere, in an attempt to reduce to the minimum the degradation of the environment caused by humans. By virtue of the Convention, the Parts2 are committed to reach their objectives in the reduction of the emissions. A Conference of the Parts was stablished to promote the effective application of the Convention. The third Conference of the Parts, celebrated in Kyoto (Japan, 1997) approved, by consensus, the denominated Kyoto Protocol, in which 39 developed countries and countries with economies in transition were committed to reduce their emissions of greenhouse gases between years 2008 and 2012 in a 5.2 global percent with respect to the 1990 levels. Three {sup f}lexibility mechanisms{sup w}ere ...

2006-07-01

477

Hard X-ray identification of Eta Carinae and steadiness close to periastron  

CERN Document Server

Context: The colliding-wind binary Eta Car exhibits soft X-ray thermal emission that varies strongly around periastron, and non-thermal emission seen in hard X-rays and gamma-rays. Aims: To definitively identify Eta Car as the source of the hard X-ray emission, to examine how changes in the 2-10 keV band influence changes in the hard X-ray band, and to understand more clearly the mechanisms producing the non-thermal emission using new INTEGRAL observations obtained close to periastron. Methods: A Chandra observation encompassing the ISGRI error circle was analysed, and all other soft X-ray sources (including the outer shell of Eta Car itself) were discarded as likely counter-parts. New hard X-ray images of Eta Car were studied close to periastron, and compared to previous observations far from periastron. Results: The INTEGRAL component, when represented by a power law (with a photon index of 1.8), ...

2010-01-01

478

H_2 emission arises outside photodissociation regions in ultra-luminous infrared galaxies  

CERN Document Server

Ultra-luminous infrared galaxies are among the most luminous objects in the local universe and are thought to be powered by intense star formation. It has been shown that in these objects the rotational spectral lines of molecular hydrogen observed at mid-infrared wavelengths are not affected by dust obscuration, leaving unresolved the source of excitation of this emission. Here I report an analysis of archival Spitzer Space Telescope data on ultra-luminous infrared galaxies and demonstrate that star formation regions are buried inside optically thick clouds of gas and dust, so that dust obscuration affects star-formation indicators but not molecular hydrogen. I thereby establish that the emission of H_2 is not co-spatial with the buried starburst activity and originates outside the obscured regions. This is rather surprising in light of the standard view that H_2 emission is directly associated with star-formation ...

2010-01-01

479

Extreme Ultraviolet Emission from Abell 4059  

CERN Document Server

We present the results of a search for Extreme Ultraviolet emission in A4059, a cluster with an X-ray emitting cluster gas. Our analysis of Extreme Ultraviolet Explorer (EUVE) Deep Survey observations of this cluster shows that it is associated with diffuse EUV emission. Outside the central 2 arcmin radius the entire EUV emission detected is explained by the low energy tail of the X-ray emitting gas. Within the central 2 arcmin region of the cluster we find a deficit of EUV emission compared to that expected from the X-ray gas. This flux deficit is discussed in the context of the cluster's cooling flow. The results derived for A4059 are compared to EUVE results obtained for other clusters such as Coma, Virgo, A1795, and A2199. As part of the study we have carried out a detailed investigation of the stability of the EUVE Deep Survey detector background. Based on long integrations of blank sky over 27 ...

2000-01-01

480

Experimental studies on specific fuel consumption and NO/sub x/ emission of diesel engine. Part 1. Effects of engine parameter and operating condition  

Energy Technology Data Exchange (ETDEWEB)

There is a great demand for the reduction of specific fuel consumption in diesel engines, and also of NO/sub x/ emission in especially those designed for use on land. However, while improving combustion, a problem arises in trying to reduce both simultaneously because the techniques required are contradictory. This series of experiments was done to study the correlation between specific fuel consumption and NO/sub x/ emission. The research was conducted under variations in engine parameters and operating conditions. The variations studied included effects of pressure, temperature and humidity of the charging air, temperature of the cooling water, timing and rate of fuel injection, fuel injection nozzle, EGR and water-emulsified fuel. The results of the tests clarified the characteristics of the specific fuel consumption and NO/sub x/ emission and indicated that the most-effective measures for the reduction of specific fuel ...

1985-01-01

481

Emissions Inventory Report Summary: Reporting Requirements for the New Mexico Administrative Code, Title 20, Chapter 2, Part 73 (20 NMAC 2.73) for Calendar Year 2001  

Energy Technology Data Exchange (ETDEWEB)

Los Alamos National Laboratory is subject to annual emissions-reporting requirements for regulated air contaminants under Title 20 of the New Mexico Administrative Code, Chapter 2, Part 73 (20.2.73 NMAC), Notice of Intent and Emissions Inventory Requirements. The applicability of the requirements is based on the Laboratory's potential to emit 100 tons per year of suspended particulate matter, nitrogen oxides, carbon monoxide, sulfur oxides, or volatile organic compounds. For calendar year 2001, the Technical Area 3 steam plant was the primary source of criteria air pollutants from the Laboratory, while research and development activities were the primary source of volatile organic compounds. Emissions of beryllium and aluminum were reported for activities permitted under 20.2.72 NMAC. Hazardous air pollutant emissions from chemical use for research and development activities were also reported.

2003-04-01

482

Emission characterization of an alcohol/diesel-pilot fueled compression-ignition engine and its heavy-duty diesel counterpart. Final report, August 1980-August 1981  

Energy Technology Data Exchange (ETDEWEB)

This report describes results from emissions testing of a prototype diesel engine, developed by Volvo Truck Corporation of Sweden, which uses pilot injection of diesel fuel for compression ignition of alcohol fuel injection for main combustion. In addition to this dual-fuel engine, emission testing was also conducted on a heavy-duty diesel engine of similar design. Both engines were tested over the 1979 13-mode FTP, or shorter versions of this modal test, and over the 1984 Transient FTP as well as an experimental bus cycle. The dual-fuel engine was characterized with methanol, ethanol and ethanol with 30 percent water (wt %). An oxidation catalyst was also used with methanol and ethanol. Emission characterization included regulated emissions (HC, CO, and NOX) along with total particulate, unburned alcohols, individual hydrocarbons, aldehydes, phenols, and odor. The particulate matter was characterized ...

1981-08-01

483

Effects of oxygenated blending compounds on emissions from a turbo-charged direct injection diesel engine  

Energy Technology Data Exchange (ETDEWEB)

An experimental investigation was conducted to evaluate the effect of three different oxygenated compounds, diglyme, diethyl maleate and dibutyl maleate, on emissions from a Volkswagen 1.9 litre, turbocharged, direct injection diesel engine. Sampling was performed using a mini-dilution tunnel technique to obtain particulate matter and a Fourier transform infrared (FTIR) spectrometer for gaseous emissions. The particulate samples were analysed using thermal analysis and Soxhlet extraction to determine the fraction of volatile and soluble organic material respectively. All three oxygenated compounds were found to be effective at reducing particulate emissions, with the maleate compounds being more effective overall than the diglyme. Analysis of the relative contributions of changes in the soot and soluble organic fraction (SOF) to the reduction of particulate matter indicated that, for diethyl maleate and diglyme, reductions ...

2000-02-01

484

Development of advanced residential cooktop burner with low NOx emissions. Annual report on phase 1, Feb 82-Oct 83  

Science.gov (United States)

This report describes the result of work completed during February, 1982 to October 1983. The aim of the work was to develop a low NO(x) emission range top burner. Discussed is the development of a flame insert modification to an existing burner which reduces NO(x) emission by 45 percent and NO2 emission by 25 percent. This relatively simple burner add-on device appears to be an economically viable low NO(x) burner. It was developed in cooperation with a major range manufacturer. The levels of NO(x) (NO2) reduction achieved should significantly reduce the impact of a gas range to indoor quality. The report also discusses the results of a literature search that preceeded the burner development. The search helped to direct the burner development by reviewing the state-of-the-art of low NO(x) burner design and covered factors which affect the indoor impact of range emissions such as air infiltration and ...

1983-11-01

485

Comparison of emissions of a direct injection diesel engine operating on biodiesel with emulsified and fumigated methanol  

Energy Technology Data Exchange (ETDEWEB)

Biodiesel is an alternative fuel for internal combustion engines. It can reduce carbon monoxide (CO), hydrocarbon (HC) and particulate matter (PM) emissions, compared with diesel fuel, but there is also an increase in nitrogen oxides (NOx) emission. This study is aimed to compare the effect of applying a biodiesel with either 10% blended methanol or 10% fumigation methanol. The biodiesel used in this study was converted from waste cooking oil. Experiments were performed on a 4-cylinder naturally aspirated direct injection diesel engine operating at a constant speed of 1800 rev/min with five different engine loads. The results indicate a reduction of CO{sub 2}, NOx, and particulate mass emissions and a reduction in mean particle diameter, in both cases, compared with diesel fuel. It is of interest to compare the two modes of fueling with methanol in combination with biodiesel. For the blended mode, there is a slightly higher ...

2008-08-15

486

Characterization of coatings and the low cycle fatigue behaviour of 316L  

Energy Technology Data Exchange (ETDEWEB)

In the framework of the European Fusion Technology Programme ECN participates in a NET task PSM-8 `Coatings and Surface Effects on Stainless Steel 316L`. High emissivity coatings were developed for enhanced heat transfer from graphite tiles to a Stainless Steel First Wall. Four candidate materials, Cr{sub 2}O{sub 3}, Black Cr, Al{sub 2}O{sub 3}/TiO{sub 2} and TiC were tested as candidate high emissivity coatings. These coatings were manufactured by atmospheric and vacuum plasma spraying technique and the Black Chromium coatings were manufactured by a galvanic coating technique. The tests included total emissivity measurements and Low Cycle Fatigue (LCF) experiments. The total emissivity of two TiC coatings at 525 K appeared to be 0.62 and 0.64. The total emissivity of the TiC and 5 wt% TiO{sub 2}/Al{sub 2}O{sub 3} coating was about 0.7. (orig.)

1993-03-01

487

Chandra Observations of Nuclear X-ray Emission from a Sample of Radio Sources  

CERN Document Server

We present the X-ray properties of a sample of 17 radio sources observed with the Chandra X-ray Observatory as part of a project aimed at studying the X-ray emission from their radio jets. In this paper, we concentrate on the X-ray properties of the unresolved cores. The sample includes 16 quasars (11 core-dominated and 5 lobe-dominated) in the redshift range z=0.30--1.96, and one low-power radio-galaxy at z=0.064. No diffuse X-ray emission is present around the cores of the quasars, except for the nearby low-power galaxy that has diffuse emission on a scale and with a luminosity consistent with other FRIs. No high-amplitude, short-term variability is detected within the relatively short Chandra exposures. However, 1510-089 shows low-amplitude flux changes with a timescale of $\\sim$25 minutes. The X-ray spectra of the quasar cores are generally well described by a single power law model with Galactic absorption. However, ...

2003-01-01

488

Assessment of the air quality impact of SO/sub 2/ emissions from the Asarco-Tacoma smelter. Final report Jun 75-Jun 76  

Science.gov (United States)

The major purpose of the work described in this report was to use diffusion modeling techniques to calculate the impact on ambient air quality of SO2 emissions from the ASARCO copper smelter in Tacoma, Washington for the existing smelter configuration (51-percent constant emissions control) and for 20 alternative smelter configurations with varying degrees of constant emissions control. The accuracy of the modeling techniques was established by the close correspondence obtained between calculated and observed short-term ground-level SO2 concentrations for 20 selected historical cases, when high hourly SO2 concentrations were measured in the area surrounding the smelter, as well as by the close agreement between calculated and observed annual average concentrations for 1972. The results of the model calculations show that the maximum allowable constant SO2 emission rate consistent with maintaining the ...

1976-07-01

489

A study on the amount of pilot injection and its effects on rich and lean boundaries of the premixed CNG/air mixture for a CNG/diesel dual-fuel engine  

Energy Technology Data Exchange (ETDEWEB)

A sequential port injection, lean-burn, fully electronically-controlled compressed natural gas (CNG)/diesel dual-fuel engine has been developed based on a turbo-charged and inter-cooled direct injection (D.I.) diesel engine. During the optimisation of engine overall performance, the effects of pilot diesel and premixed CNG/air mixture equivalence ratio on emissions (CO, HC, NO{sub x}, soot), knocking, misfire and fuel economy are studied. The rich and lean boundaries of the premixed CNG/air mixture versus engine load are also provided, considering the acceptable values of NO{sub x} and THC emissions, respectively. It is interesting to find that there is a critical amount of pilot diesel for each load and speed point, which proved to be the optimum amount of pilot fuel. Any decrease in the amount of pilot diesel from this optimum amount results in an increase of NO{sub x} emissions, because the premixed CNG/air mixture must ...

2003-07-01

490

Size and morphology of heavy-duty vehicle particle emissions; Raskaan ajoneuvokannan hiukkaspaeaestoen koko ja morfologia - HD-PM  

Energy Technology Data Exchange (ETDEWEB)

Formation of particles from heavy duty diesel and CNG vehicles was studied in laboratory conditions. PM, nano and soot mode particle emissions formed from buses of Euro 2-5 -emission levels were studied in relation to age and type approval characteristics of the vehicle. Characteristic particle emission factors from city driving were obtained by driving the buses on VTT's heavy duty chassis dynamometer applying the transient Braunschweig city cycle. The vehicles were a representative set of Euro 2 to 3 emission categories, supplemented with Euro 4-5 (EEV) -targeted CRT, CNG and DPF cars. Particle number emissions from Euro 4 to 5 buses were 1/100-1/1000 and mass emissions 1/10-1/100 of those of the current fleet. Particle emission from natural gas buses and after an advanced CRT trap contained almost entirely liquid < 60 nm ...

2006-10-15

491

Radionuclide Air Emissions Report for the Hanford Site Calendar year 1998  

Energy Technology Data Exchange (ETDEWEB)

This report documents radionuclide air emissions from the Hanford Site in I998 and the resulting effective dose equivalent to the maximally exposed individual (MEI) member of the public. The report has been prepared in accordance with the Code of Federal Regulations, Title 40, Protection of the Environment, Part 61, National Emission Standards for Hazardous Air Pollutants (40 CFR SI), Subpart H, ''National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities,'' and with the Washington Administrative Code Chapter 246-247, Radiation Protection--Air Emissions. The federal regulations in 40 CFR 61, Subpart H; require the measurement and reporting of radionuclides emitted from Department of Energy facilities and the resulting offsite dose from those emissions. A standard of 10 ...

1999-06-15

492

Characterization of Single-Cylinder Small-Bore 4-Stroke CIDI Engine Combustion  

Energy Technology Data Exchange (ETDEWEB)

Direct injection diesel engines power most of the heavy-duty vehicles. Due to their superior fuel economy, high power density and low carbon dioxide emissions, turbocharged, small bore, high speed, direct injection diesel engines are being considered to power light duty vehicles. Such vehicles have to meet stringent emission standards. However, it is difficult to meet these standards by modifying the in-cylinder thermodynamic and combustion processes to reduce engine-out emissions. After-treatment devices will be needed to achieve even lower emission targets required in the production engines to account for the anticipated deterioration after long periods of operation in the field. To reduce the size, mass and cost of the after-treatment devices, there is a need to reduce engine-out emissions and optimize both the engine and the aftertreatment devices as one integrated system. For ...

2005-11-30

493

No 2965, No 254. Report on new energy technologies and carbon dioxide sequestration: scientifical and technical aspects; N. 2965, N. 254. Rapport sur les nouvelles technologies de l'energie et la sequestration du dioxyde de carbone: aspects scientifiques et techniques  

Energy Technology Data Exchange (ETDEWEB)

The abatement of CO{sub 2} emissions is a huge technical and economical challenge. Fossil fuels, which represent 88% of the world primary energy consumption, are the main source of the 25 billions of CO{sub 2} released each year in the atmosphere. The mastery of CO{sub 2} emissions cannot come from a single technology but must result from the simultaneous implementation of several means, like the development of carbon-free energies and the mastery of fossil fuel emissions. The opportunities of progress are numerous and compatible with the economic development. This document presents, first, the different greenhouse gases, the CO{sub 2} emissions per country and the main sources of CO{sub 2} emissions (power and heat generation, transports). Then it presents different ways of abatement of CO{sub 2} emissions: clean coal technologies, gas combined cycles, CO{sub ...

2006-03-15

494

Near infrared to red and yellow to blue upconversion emissions from Pr{sup 3+}: ZrF{sub 4}-BaF{sub 2}-LaF{sub 3}-YF{sub 3}-AlF{sub 3}-NaF glasses  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the development and a detailed analysis carried out on the luminescence characteristics of Pr{sup 3+} doped ZrF{sub 4}-BaF{sub 2}-LaF{sub 3}-YF{sub 3}-AlF{sub 3}-NaF glasses. In the present work our objectives are to elucidate the possible mechanisms that are responsible for NIR to red upconversion process and yellow to blue upconversion emission in terms of energy level schemes from the praseodymium containing fibre optical glass composition. We have studied their different physical and optical properties. Besides our investigation on the upconversion emission of these glasses, normal fluorescence studies have also been undertaken in explaining the mechanisms in demonstrating bright red and blue emissions upon excitations at visible and UV wavelengths. Besides these measurements works, a bright blue colour emission was observed under an UV source (202 nm) and upconverted prominent ...

2004-04-15

495

NO_x emissions from large point sources: variability in ozone production, resulting health damages and economic costs  

International Nuclear Information System (INIS)

We present a proof-of-concept analysis of the measurement of the health damage of ozone (O_3) produced from nitrogen oxides (NO_x=NO+NO_2) emitted by individual large point sources in the eastern United States. We use a regional atmospheric model of the eastern United States, the Comprehensive Air quality Model with Extensions (CAMx), to quantify the variable impact that a fixed quantity of NO_x emitted from individual sources can have on the downwind concentration of surface O_3, depending on temperature and local biogenic hydrocarbon emissions. We also examine the dependence of resulting O_3-related health damages on the size of the exposed population. The investigation is relevant to the increasingly widely used 'cap and trade' approach to NO_x regulation, which presumes that shifts of emission over time and space, holding the total fixed over the course of the summer O_3 season, will have minimal effect on the environmental outcome. By ...

2005-05-01

496

GHG emissions, GDP growth and the Kyoto Protocol: A revisit of Environmental Kuznets Curve hypothesis  

Energy Technology Data Exchange (ETDEWEB)

The Kyoto Protocol attempts through political negotiations to guide participating industrialized countries' greenhouse gas (GHG) emissions from a positive growing trend, to reach a peak point (or turning point), and then be reduced to a negative growth. That means the relationship between decreasing GHG emissions and economic growth may be described by an inverted-U curve (or called a bell-shaped curve), which is consistent with the concept of the Environmental Kuznets Curve (EKC) hypothesis. This research observed that the economic development and GHG emissions in Economies in Transition (EITs) exhibit a hockey-stick curve trend (or called quasi-L-shape curve), that also generates a lot of 'hot air' which is significant to the implementation of the Kyoto Protocol. In addition, through the analysis of single-country time series data and GDP data, this research demonstrated that statistical data ...

2008-01-15

497

GHG emissions, GDP growth and the Kyoto Protocol: A revisit of Environmental Kuznets Curve hypothesis  

Energy Technology Data Exchange (ETDEWEB)

The Kyoto Protocol attempts through political negotiations to guide participating industrialized countries' greenhouse gas (GHG) emissions from a positive growing trend, to reach a peak point (or turning point), and then be reduced to a negative growth. That means the relationship between decreasing GHG emissions and economic growth may be described by an inverted-U curve (or called a bell-shaped curve), which is consistent with the concept of the Environmental Kuznets Curve (EKC) hypothesis. This research observed that the economic development and GHG emissions in Economies in Transition (EITs) exhibit a hockey-stick curve trend (or called quasi-L-shape curve), that also generates a lot of 'hot air' which is significant to the implementation of the Kyoto Protocol. In addition, through the analysis of single-country time series data and GDP data, this research demonstrated that statistical data ...

2008-01-15

498

Economic policy instruments for the control of air pollution in Poland  

International Nuclear Information System (INIS)

The World Bank is analyzing the role of economic policy instruments for the control of air pollution in Poland, in cooperation with Polish and international experts. The first stage, covering Poland as a whole, was recently completed, jointly financed with the U.S. E.P.A. and the Government of the Netherlands. The second stage, now under way, will extend the analysis into a specific regional framework. Stage 2 is financed by the World Bank, the Polish Government, and the U.K. Environment Know-How Fund. Air Pollution in Poland is overwhelmingly caused by energy production and uses, due to the fact that the Polish economy depends heavily on coal and lignite. At present, vehicles contribute less to total emissions than do coal burning and industrial processes, although they account for 25-35% of nitrogen oxides, carbon monoxide, hydrocarbons and lead; and the concentrated in areas of high population density. The paper shows how economic, technical and meteorological ...

1993-06-13

499

Comparison of central heating with district heating and small-scale cogeneration. Vergelijking van centrale verwarming met stadsverwarming en kleinschalige warmtekoppeling; Energiebesparing, emissies en financiele resultaten  

Energy Technology Data Exchange (ETDEWEB)

Three systems for the heat supply in the built environment have been compared for the costs, the energy consumption and emissions of CO{sub 2}, NO{sub x} and SO{sub 2}. The heating systems compared are based on central heating boilers, district heating systems in combination with combined steam and gas turbine cycles, and heating by means of several gas engines. From the results it appears that the boilers demand the lowest investments. The district heating systems are more expensive. Both heating systems, however, show considerable savings of energy (55 to 70%). The exploitation costs depend strongly on the fuel price scenarios used and the assumptions with regard to interest and inflation. The emissions of CO{sub 2} are also considerably lower for both combined heat and power generating systems. The use of gas engines results in higher acidifying emissions compared to the system with the central heating boilers, and lower ...

1991-07-01

500

An experimental investigation of H{sub 2} emissions of a 2004 heavy-duty diesel engine supplemented with H{sub 2}  

Energy Technology Data Exchange (ETDEWEB)

Hydrogen (H{sub 2}) emissions characteristics of H{sub 2}-diesel dual fuel engine were measured using a 2004 turbocharged heavy-duty diesel engine with H{sub 2} supplemented into the intake air. The emissions of H{sub 2} were measured using an Electron Pulse Ionization (EPI) Mass Spectrometer (MS). The effect of the amount of H{sub 2} added, the engine load, and diesel fuel flow rates on the emissions of H{sub 2} and its combustion efficiency in the engine were investigated. The addition of H{sub 2} under high load operation was notable for its ability to obtain high H{sub 2} combustion efficiency and improve brake thermal efficiency. However, the addition of H{sub 2} at low load resulted in high emissions of H{sub 2} due to the failure to initiate and support a sufficiently vigorous flame for the complete combustion of H{sub 2} present outside the diesel spray plume. The maximum H{sub 2} ...

2010-10-15