WorldWideScience
1

{sup 18}F-labeled styrylpyridines as PET agents for amyloid plaque imaging  

Energy Technology Data Exchange (ETDEWEB)

Positron emission tomography (PET) imaging of {beta}-amyloid (A{beta}) plaques in the brain is a potentially valuable tool for studying the pathophysiology of Alzheimer's disease (AD). It may also be applicable for measuring the effectiveness of therapeutic drugs aimed at lowering A{beta} plaques in the brain. We have successfully reported a series of {sup 18}F-labeled fluoropegylated stilbenes for PET imaging studies. Encouraging results clearly demonstrated the usefulness of {sup 18}F-labeled stilbenes as potential A{beta} plaque-imaging agents. In the present study, we applied a similar approach to a styrylpyridine backbone structure. Among all derivatives examined (E)-2-(2-(2-(2-fluoroethoxy)ethoxy)ethoxy)-5-(4-dimethylaminostyryl) -pyridine (2) displayed high binding affinity in postmortem AD brain homogenates (K {sub i}=2.5{+-}0.4 nM, with [{sup 125}I]IMPY as radioligand). ...

2007-01-15

2

Strength and fluoride release characteristics of a calcium fluoride based dental nanocomposite  

UK PubMed Central (United Kingdom)

Secondary caries and restoration fracture remain the two most common problems in restorative dentistry. Release of fluoride ions (F) could be a substantial benefit because F could enrich neighboring...Full Text Available

2008-11-01

3

Automated synthesis of hypoxia imaging agent [18F]FMISO based upon a modified Explora FDG4 module  

British Library Electronic Table of Contents (United Kingdom)

A new automated synthesis procedure of 1-H-1-(3-[18F]fluoro-2-hydroxypropyl)-2-nitroimidazole ([18F]FMISO), a specific hypoxia imaging agent with great significances for the noninvasive, dynamic hypoxia evaluation of cancer, was developed by modifying Explora FDG4 module, a commercial [18F]FDG production system, in this study. Its radiochemical synthesis was carried out via two sequent reaction steps, i.e. the nucleophilic displacement of labeling precursor 1-(2?-nitro-1?-imidazolyl)-2-O-tetrahydropyranyl-3-O-tosyl-propaned iol (NITTP) with activated 18F- ion at 100 ?C for 8 minutes, and the following hydrolysis with 1M HCl at 100 ?C for 5 minutes and neutralization with 1M NaOH. Two-pot reaction with two independent separations was adopted to assure the good separation of final product vi...

2009-01-01

4

Fluoride release from an orthodontic glass ionomer adhesive in vitro and enamel fluoride uptake in vivo  

British Library Electronic Table of Contents (United Kingdom)

Introduction The objective of this study was to investigate the in-vitro fluoride release from a glass ionomer orthodontic bonding system (Fuji I, GC Corporation, Tokyo, Japan) over a 2-month period and the in-vivo enamel fluoride uptake after 6 months. Methods Ten metal brackets were bonded with either glass ionomer or composite resin (Transbond XT, 3M Unitek, Monrovia, Calif; Light Cure), which served as controls, to recently extracted molars. The bonded teeth, cut at the level of their roots, were stored in distilled water that was renewed after every fluoride measurement at 1, 3, 7, 30, and 60 days. The in-vitro fluoride release was measured by using a fluoride ion-selective electrode, connected to an ion analyzer. Fifteen pairs of premolars were bonded with metal brackets with either ...

2010-01-01

5

Fluoride ion catalyzed alkylation of purines, pyrimidines, nucleosides and nucleotides using alky halides.  

UK PubMed Central (United Kingdom)

Alkyl halides react rapidly with purines and pyrimidines in the presence of fluoride ion. Alkylation of thymidine leads to novel dimeric nucleoside derivatives bridged through N3. Alkylation of thymidine...Full Text Available

1979-04-01

6

Fluoride ion promoted deprotection and transesterification in nucleotide triesters.  

UK PubMed Central (United Kingdom)

Tetrabutylammonium fluoride will remove phenyl, trichloroethyl and cyanoethyl groups from nucleotides. In addition to the desired nucleotide products other results including chain cleavage, phosphofluoridates...Full Text Available

1979-10-10

7

An analytic representation of the radial distribution of dose from energetic heavy ions in water, Si, LiF, and NaI  

International Nuclear Information System (INIS)

An earlier representation of the radial distribution of dose about the path of a heavy ion in liquid water is modified and extended to include silicon, lithium fluoride, and sodium iodide. 6 refs., 5 figs., 1 tab.

1989-09-01

8

Volatilization of fluorides from solid uranium(IV)fluoride  

International Nuclear Information System (INIS)

... deposition evaporation fission products fluorides iodine 134 laboratory

1971-02-01

9

Facile synthesis of additive-assisted nano goethite powder and its application for fluoride remediation  

Energy Technology Data Exchange (ETDEWEB)

The present article describes a novel synthesis route for nano-sized goethite ({alpha}-FeOOH) using hydrazine sulphate as an additive. The X-ray diffraction (XRD) peaks of synthesized powder matched well with those of {alpha}-FeOOH. Transmission electron microscopy (TEM) showed the particles of irregular shape in the range of 1-10 nm. Batch adsorption experiments for fluoride uptake were performed to study the influence of various experimental parameters such as contact time (10 min to 7 h), initial fluoride concentration (10-150 mg L{sup -1}), pH (2-11.6) and the presence of competing anions. The time data fitted well to pseudo-second-order kinetic model. The fluoride removal passed through broad maxima in pH ranges of 6-8. High adsorption capacity of 59 mg g{sup -1} goethite was obtained. The isothermic data fitted well to Freundlich model. The presence of other ions namely chloride and sulphate ...

2010-02-15

10

Autoradiographic and small-animal PET comparisons between 18F-FMISO, 18F-FDG, 18F-FLT and the hypoxic selective 64Cu-ATSM in a rodent model of cancer  

British Library Electronic Table of Contents (United Kingdom)

IntroductionCopper(II)-diacetyl-bis(N4-methylthiosemicarbazone), or Cu-ATSM, a hypoxia imaging agent, has been shown to be predictive of response to traditional cancer therapies in patients with a wide range of tumors. It is known that the environment of the tumor results in a myriad of physiological consequences, including hypoxia, alterations in metabolism and proliferation. In an effort to better characterize the relationships between Cu-ATSM and other prominent radiopharmaceuticals, this current study was undertaken to compare the regional distribution of 64Cu-ATSM with [18F]fluoromisonidazole (18F-FMISO), [18F]fluoro-2-deoxy-d-glucose (18F-FDG) and [18F]fluorothymidine (18F-FLT) in 9L tumors.MethodsTaking advantage of the different ...

2008-01-01

11

Theoretical study on the effects of oxygen doping on the lithium ion conductive perovskite-type manganese fluoride of KxBa(1-x)/2MnF3  

British Library Electronic Table of Contents (United Kingdom)

Previously, we demonstrated that the lithium ion conduction in the perovskite-type manganese fluoride is attributed to counter cation-site vacancy mechanism. The divalent counter cation-doped KxBa(1-x)/2MnF3 was theoretically predicted as the lithium ion conductor in the perovskite-type manganese fluoride. In this study, we considered the oxygen doping for KxBa(1-x)/2MnF3 to realize the higher lithium ion conductivity. It is because lithium ion forms the stronger ionic bond with the doped oxygen anion. The hybrid-DFT calculations were performed to investigate the lithium ion conduction in the oxygen-doped KxBa(1-x)/2MnF3. The calculation results were discussed from the viewpoints of the potential energy curve, electron densities, and charge and spin densities. The effect of the lithium ion...

2009-01-01

12

Paramagnetic susceptibility of nonstoichiometric fluorides with the fluorite-type structure  

Energy Technology Data Exchange (ETDEWEB)

Magnetic properties of single crystals of nonstoichiometric fluorides M[sub 1-x]R[sub x]F[sub 2+x] (M = Ca, Sr, Ba; R = Ce, Pr, Nd, Gd, Ho, Er, Tm, Yb; with 0.05 [le] x [le] 0.28) with the fluorite-type structure have been studied for the first time. The magnetic susceptibility was measured using a Faraday balance in the 15-300 K temperature range. The samples are paramagnetic following the Curie-Weiss law. The values of paramagnetic Curie temperatures and effective magnetic moments of rare-earth ions have been found. Deviations of the temperature dependence of magnetic susceptibility from the Curie-Weiss law are observed for some nonstoichiometric fluorides at temperatures ranging from 60 to 85 K. Possible reaons for these deviations are discussed. Measurements of magnetic susceptibility provide an effective technique for a rapid and accurate determination of the concentration of rare-earth ions in ...

1993-01-01

13

Effects of anesthesia upon "1"8F-FDG uptake in rhesus monkey brains  

International Nuclear Information System (INIS)

The kinetics of "1"8F-fluorodeoxyglucose ("1"8F-FDG) in the monkey brain were monitored, and comparisons were made between the conscious state and when under ketamine and pentobarbital anesthesia. Rhesus monkeys were intravenously injected with "1"8F-FDG and followed by 60 min of PET scanning. In the conscious state, the "1"8F-FDG concentration reached a plateau 5 min after intravenous injection. Under ketamine anesthesia, the "1"8F-FDG concentration gradually increased with time in all monitored regions. At 60 min after injection, the concentration in the striatum was about 3.2 times greater than that in the conscious state, and about 4.5 times greater in the cerebral cortex. Under pentobarbital anesthesia, the "1"8F-FDG concentration in the occipital cortex was slightly lower. These findings demonstrate that "1"8F-FDG concentration in the monkey brain is significantly affected by anesthesia. The results also imply the existence of a short-term regulation mechanism for hexokinase ...

2005-07-01

14

Correlation of angiogenesis with "1"8F-FMT and "1"8F-FDG uptake in non-small cell lung cancer  

International Nuclear Information System (INIS)

L-[3-"1"8F]-#alpha#-methyltyrosine ("1"8F-FMT) is an amino-acid tracer for positron-emission tomography (PET). We have conducted a clinicopathologic study to elucidate the correlation of angiogenesis with "1"8F-FMT and 2-["1"8F]-fluoro-2-deoxy-D-glucose ("1"8F-FDG) uptake in patients with non-small cell lung cancer (NSCLC). Thirty-seven NSCLC patients were enrolled in this study, and two PET studies with "1"8F-FMT and "1"8F-FDG were performed. Uptake of PET tracers was evaluated with standardized uptake value. Vascular endothelial growth factor (VEGF), CD31, CD34, L-type amino acid transporter 1 (LAT1) and Ki-67 labeling index of the resected tumors were analyzed by immunohistochemical staining, and correlated with the clinicopathologic variables and the uptake of PET tracers. The median VEGF rate was 45% (range, 10-78%). High expression was seen in 30 patients (81%, 30/37). VEGF expression was statistically associated with progressively growing microvessel count. VEGF showed a ...

2009-04-01

15

Fluoride phosphate Li{sub 2}CoPO{sub 4}F as a high-voltage cathode in Li-ion batteries  

Energy Technology Data Exchange (ETDEWEB)

As a new high-voltage cathode candidate for post 4V cathodes, ordered-olivine LiCoPO{sub 4} and fluoride phosphate, Li{sub 2}CoPO{sub 4}F were synthesized by solid-state reaction. Their structures were identified by neutron diffraction. The 5V discharge profiles were demonstrated using coin-type cells. Two important issues for commercial use, metal dissolution and oxygen release at elevated temperatures, were also tested with an atomic absorption spectrophotometer and differential scanning calorimeter, respectively. (author)

2005-08-26

16

Measurement of the 183 keV Resonance in 17O(p,alpha)14N using a Novel Technique  

Energy Technology Data Exchange (ETDEWEB)

We have developed a novel technique for measurements of low energy (p,alpha) reactions using heavy ion beams and a differentially-pumped windowless gas target. We applied this new approach to study the 183 keV resonance in the 17O(p,alpha)14}N reaction. We report a resonance energy (center-of-mass) of 183.5{+0.1}{-0.4} keV, a resonance strength of 1.70 +/- 0.15 meV, and set an upper limit (95\\% confidence) on the total width of the state of < 0.1 keV. This resonance is important for the 17O(p,alpha)14}N reaction rate, and we find that 18F production is significantly decreased in low mass ONeMg novae but less affected in more energetic novae. We also report the first determination of the stopping power for oxygen ions in hydrogen gas near the peak of the Bragg curve (E=193 keV/u) to be (63+/-1)e-15 eV-cm2.

2007-06-01

18

Oxidation kinetics of tetravalent uranium monofluoride complex by nitrous acid in HNO_3 medium  

International Nuclear Information System (INIS)

The kinetics of oxidation of uranium (IV) monofluoride complex by nitrous acid in nitric acid solution have been studied. The experiments were carried out at constant ionic strength of 2M (HNO_3 and NaNO_3) and temperature in the range of 18-47 deg C. The rate of reaction was determined spectrophotometrically at a wavelength of 621 nm, at which the molar extinction coefficients of UF"3"+ and UF_2"2"+ are the same. It was shown that reaction orders for [HNO_2] and [HNO_3] are equal to 0.12 and 0.39, respectively. The values of activation parameters #DELTA#H"#not =# and #DELTA#S"#not =# are determined to be 83 kJ mol"-"1 and 75 J (mol.K)"-"1, respectively. The rate order of the reaction studied has a weak direct depedence on [H"+] in contrary to the strong and reverse dependence in the absence of fluoride ions. In conclusion, fluoride ions may strongly stabilize the U(IV) in nitric acid solutions. ...

1991-08-01

19

Preparation of poly (aryl ether ketones) in the presence of an alkali, alkaline earth of lanthanide metal salt  

Energy Technology Data Exchange (ETDEWEB)

This patent describes a process for preparing poly(aryl ether ketones) by nucleophilic displacement polymerization in the presence of at least one alkali metal base selected from potassium, rubidium or cesium, and fluoride ions, which comprises adding to the polymerization: (a) an effective amount of at least one metal salt selected from lithium, sodium, alkaline earth or lanthanide chloride, bromide, iodide, sulfate, alkyl or aryl carboxylate, cyanide, borate or phosphate to slow or stop advancement of molecular weight and (b) an end-capping agent.

1988-09-27

20

Preparation of new proton exchange membrane based on self-assembly of poly(styrene-co-styrene sulfonic acid)-b-poly(methyl methacrylate)/poly(vinylidene fluoride) blend  

Energy Technology Data Exchange (ETDEWEB)

Amphiphilic block copolymers are synthesized by sulfonation of poly(styrene-b-methyl methacrylate) (PS-b-PMMA) using acetyl sulfate, and are blended with poly(vinylidene fluoride) (PVDF) to prepare a new proton exchange membrane, in which PMMA is miscible with PVDF. The morphology and the transport properties of the membranes are investigated as functions of the degree of sulfonation as well as the blend ratio. Notable transition of phase-separated morphology is observed as the PVDF content of the blend is increased. Both the proton conductivity and the ion-exchange capacity (IEC) of the membrane increase with increasing the degree of sulfonation of PS-b-PMMA, and they are also enhanced as the phase-separated domains of blend membrane are well-ordered. Unlike the Nafion membrane, the proton conductivity of the blend membrane increases up to 90 C, indicating the blend membrane shows better thermal stability than the Nafion membrane. (author)

2009-03-01

21

Effect of halogens and inhibitors on the external stress corrosion cracking of Type 304 austenitic stainless steel  

Energy Technology Data Exchange (ETDEWEB)

The methodology of the drip procedure of the Standard Test Method for Evaluating the Influence of Thermal Insulation on External Stress Corrosion Cracking Tendency of Austenitic Stainless Steel (ASTM C 692-95a) was used to research the effect of halogens and inhibitors on the external stress corrosion cracking (ESCC) of Type 304 stainless steel as it applies to the insulation industry. Simulated insulation extraction solutions were made with pure chemical reagents for the halogens and inhibitors. The results indicated that sodium silicate compounds that were higher in sodium were more effective for preventing chloride-induced ESCC in Type 304 austenitic stainless steel. Potassium silicate was not as effective as sodium silicate. Fluoride, bromide, and iodide may cause ESCC but they were much less active than chloride and could be effectively inhibited by sodium silicate compound. The addition of fluoride ions to the ...

1997-11-01

22

Lithium carbon batteries with solid polymer electrolyte; Accumulateur lithium carbone a electrolyte solide polymere  

Energy Technology Data Exchange (ETDEWEB)

The lithium carbon batteries studied in this paper use plasticized polymer electrolytes made with passive polymer matrix swollen by a liquid electrolyte with a high ionic conductivity (> 10{sup -3} S/cm at 25 deg. C). The polymers used to prepare the gels are polyacrylonitrile (PAN) and vinylidene poly-fluoride (PVdF). The electrochemical and physical properties of these materials are analyzed according to their composition. The behaviour of solid electrolytes with different materials of lithium ion insertion (graphite and LiNiO{sub 2}) are studied and compared to liquid electrolytes. The parameters taken into account are the reversible and irreversible capacities, the cycling performance and the admissible current densities. Finally, complete lithium ion batteries with gelled electrolytes were manufactured and tested. (J.S.) 2 refs.

1996-12-31

23

Temporal variations of fluoride concentration in Isparta public water system and health impact assessment (SW-Turkey)  

British Library Electronic Table of Contents (United Kingdom)

Water?rock interaction is one of the prime factors affecting the fluoride contents of surface and groundwater. If fluoride concentration of drinking water has been neglected, excess fluoride can cause serious dental and medical problems on human health, which is well known at Golcuk-Isparta region. In the research area, Egirdir lake, Golcuk lake and surrounding springs have been utilized as drinking water sources. Golcuk lake water and surrounding groundwaters have high fluoride content (1.4?4.6?mg/l), which is above the WHO standards. Fluoride is predominantly supplied by dissolution of fluoride within the fluormicas of volcanics during the circulation of water. Fluoride concentrations of waters have shown variations for dry and rainy seasons depending on the degree of interaction between...

2008-01-01

24

Influence of fluorine on the simulation of the transient enhanced diffusion of 15 keV BF_2"+ ion implantation into silicon  

International Nuclear Information System (INIS)

We have simulated the transient enhanced diffusion (TED) of boron fluoride (BF_2"+) implanted in crystalline and germanium amorphized silicon. Based on recently published models, the effect of fluorine on boron diffusion in silicon has been introduced and a modelling has been suggested. In order to simulate the boron experimental profiles, we have assumed that fluorine forms clusters involving interstitial boron which reduces the junction depth. Experimental results indicate that fluorine behaviour depends on amorphization energy. Moreover, even no germanium preamorphization is performed, silicon is still amorphized by fluorine species. Hence, BF_2"+ implantation leads to an amorphous/crystalline (a/c) interface near the surface. An improvement of published models is suggested taking into account fluorine effects. The simulations satisfactory reproduce the SIMS experimental profiles for a large scale of experimental conditions.

2002-01-01

25

Extraction behavior of short-lived isotopes of Mo/W using {alpha}-benzoinoxime: a model system for the study of seaborgium  

Energy Technology Data Exchange (ETDEWEB)

The liquid-liquid extraction behavior of short-lived molybdenum and tungsten isotopes from HCl and HNO{sub 3} as well as HF/HNO{sub 3} acid media was studied using the {alpha}-benzoinoxime/chloroform system. The goal of the present experiments was to find an extraction system with a high selectivity for the group 6 elements in the periodic table which is suitable for the study the solution chemistry of seaborgium (Z = 106). It was found that Mo and W are both effectively extracted using {alpha}-benzoinoxime as an extractant and the maximum extraction yield is 100% and 94% for Mo and W, respectively. Ions of MO{sub 2}{sup 2+} (M = Mo, W) exist in HCl between the concentration range of 0.1-3 M and can be extracted quantitatively into the organic phase. The decrease of extraction yields at lower or higher acid concentration is due to the formation of anionic species MO{sub 4}{sup 2-} or MO{sub 2}Cl{sub 3}{sup -}. The extraction behavior of Mo and W in HNO{sub 3} ...

2009-07-01

26

Extraction behavior of short-lived isotopes of Mo/W using #alpha#-benzoinoxime: a model system for the study of seaborgium  

International Nuclear Information System (INIS)

The liquid-liquid extraction behavior of short-lived molybdenum and tungsten isotopes from HCl and HNO_3 as well as HF/HNO_3 acid media was studied using the #alpha#-benzoinoxime/chloroform system. The goal of the present experiments was to find an extraction system with a high selectivity for the group 6 elements in the periodic table which is suitable for the study the solution chemistry of seaborgium (Z = 106). It was found that Mo and W are both effectively extracted using #alpha#-benzoinoxime as an extractant and the maximum extraction yield is 100% and 94% for Mo and W, respectively. Ions of MO_2"2"+ (M = Mo, W) exist in HCl between the concentration range of 0.1-3 M and can be extracted quantitatively into the organic phase. The decrease of extraction yields at lower or higher acid concentration is due to the formation of anionic species MO_4"2"- or MO_2Cl_3"-. The extraction behavior of Mo and W in HNO_3 solution is similar to that in HCl solution. In ...

27

Fluoride rinsing and dental health inequalities in 11-year-old children: an evaluation of a supervised school-based fluoride rinsing programme in Edinburgh  

British Library Electronic Table of Contents (United Kingdom)

Levin KA, Jones CM, Wight C, Valentine C, Topping GVA, Naysmith R. Fluoride rinsing and dental health inequalities in 11-year-old children: an evaluation of a supervised school-based fluoride rinsing programme in Edinburgh. Community Dent Oral Epidemiol 2009; 37: 19-26. Copyright 2009 The Authors. Journal compilation Copyright 2009 John Wiley &Sons A/S Abstract - Objectives: Previous studies have shown that fluoride mouthrinsing programmes are effective in reducing caries among children and adolescents. National surveys of child dental health in the UK confirm that there is variation in oral health. In particular, children of low socioeconomic status in Scotland have a disproportionately high share of dental disease. This study aimed to evaluate an existing school-based fluoride mouthrinsi...

2009-01-01

28

Different "1"8F-FDG Uptake According to Tumor Location and Morphology of Cholangiocarcinoma and Its Clinical Implication  

International Nuclear Information System (INIS)

"1"8F-fluorodeoxyglucose (FDG) uptake on positron emission tomography (PET) scan has been found to reflect tumor aggressiveness and prognosis in various types of cancer. However, pattern of FDG uptake in biliary malignancies and its clinical significance have not been studied well. The purpose of this study was to assess the additional value of "1"8F-FDG PET in differential diagnosis and prognosis of cholangiocarcinoma (CC) according to the tumor location and tumor morphology. From April 2005 to May 2008, eighty two patients (M:F=55:27, age 66.2#+-#9.6 yrs) with CC underwent "1"8F-FDG PET. For semiquantitative analysis, the maximum standardized uptake value (SUV_m_a_x) was obtained from the primary tumor. The difference of SUV_m_a_x according to the tumor location and tumor growth pattern, such as scirrhous type, nodular type, polypoid type were compared. Overall sensitivity of PET scan was 81.7% in CC. SUV_m_a_x on PET scan in intrahepatic CC was significantly higher compared to ...

2009-08-01

29

Calibration of the Capintec CRC-712M dose calibrator for "1"8F  

International Nuclear Information System (INIS)

Primary standardisation was performed on a solution of "1"8F using the 4#pi##beta#-#gamma# coincidence counting efficiency-tracing extrapolation method with "6"0Co used as a tracer nuclide. The result was used to calibrate the ANSTO secondary standard ionisation chamber which is used to disseminate Australian activity standards for gamma emitters. Using the secondary activity standard for "1"8F, the Capintec CRC-712M dose calibrator at the Australian National Medical Cyclotron (NMC) Positron Emission Tomography (PET) Quality Control (QC) Section was calibrated. The dial setting number recommended by the manufacturer for the measurement of the activity of "1"8F is 439. In this work, the dial setting numbers for the activity measurement of the solution of "1"8F in Wheaton vials were experimentally determined to be 443+/-12, 446+/-12, 459+/-11, 473+/-15 for 0.1, 1, 4.5 and 9ml solution volumes, respectively. The uncertainties given above are expanded uncertainties (k=2) giving an ...

2006-04-01

30

Process and apparatus for chemically removing ash from coal  

Science.gov (United States)

Finely divided ash-containing coal is immersed in an aqueous solution of hydrochloric acid or citric acid, and acidic ammonium fluoride to cause the ash to react with the acid and the acidic ammonium fluoride, and the deashed coal is thereafter separated from the solution.

1984-01-03

31

Corrosion Behavior of Titanium Grade 7 in Fluoride-Containing NaCl Brines.  

Science.gov (United States)

The effects of fluoride on the corrosion behavior of Titanium Grade 7 (0.12-0.25% Pd) have been investigated. Up to 0.1 mol/L fluoride was added to the NaCl brines at 95oC, and three pH values of 4, 8, and 11 were selected for studying pH dependence of fl...

2004-01-01

32

Calcium fluoride window mounting  

International Nuclear Information System (INIS)

A technique has been developed for joining a large calcium fluoride crystal to a stainless-steel flange by means of a silver transition ring. The process involves both vacuum brazing using a copper-silver alloy and air brazing using silver chloride. This paper describes the procedure used in fabricating a high-vacuum leak-tight calcium fluoride window assembly.

33

Electron-beam-plasma ion source as source of negative fluorine  

Energy Technology Data Exchange (ETDEWEB)

Radioactive ion beams (RIBs) of short-lived isotopes of fluorine are in demand for investigating astrophysical phenomena related to the hot CNO cycle and rp processes responsible for stellar nucleosynthesis. Since negative ion beams are required for injection into tandem electrostatic accelerators, such as the 25 MV tandem accelerator used for post acceleration of RIBs for the Holifield Radioactive Ion Beam Facility (HRIBF) research program at the Oak Ridge National Laboratory (ORNL), efficient, direct-formation F{sup -} ion sources are highly desirable for RIB applications involving this type of post-accelerator. We have conceived and evaluated a direct extraction F{sup -} source for potential RIB applications which is predicated on the reverse polarity operation of a positive electron-beam-plasma target/ion source (EBPTIS) while simultaneously feeding fluorine rich compounds and ...

1997-11-01

34

Assessment of groundwater quality in crystalline fractured aquifers in rural agricultural area of the mid-western coastal parts of South Korea  

International Nuclear Information System (INIS)

Full text: Groundwater in rural agricultural area of South Korea is an important source of drinking and agricultural water. The study area is located in mid-western coastal parts and has fractured bedrock aquifers whose lithologies are composed of Jurassic granites, Paleozoic sedimentary rocks, Precambrian schists and gneiss. Bedrock groundwater was slightly alkaline and had electrical conductivity of 40 to 1570 #mu#S/cm with median values of 322 #mu#S/cm. Water types based on major ions showed that Ca-HCO_3 and Ca-CI types are dominant and Na-HCO_3 and Na-CI types are minor. Intense agricultural activities resulted in significant nitrate contamination of groundwater. 22% and 40% of wells have exceeded drinking water standards (DWS) for bedrock and shallow wells, respectively. In coastal areas, slightly saline groundwater is observed for both bedrock and shallow wells. Groundwater in granitic rocks may have higher concentrations of Rn, U and F. Most wells had ...

2010-11-15

35

Synthesis of hypoxia imaging agent 1-(5-deoxy-5-fluoro-?-d-arabinofuranosyl)-2-nitroimidazole using microfluidic technology  

British Library Electronic Table of Contents (United Kingdom)

Introduction.Microfluidic technology allows fast reactions in a simple experimental setup, while using very low volumes and amounts of starting material. Consequently, microfluidic technology is an ideal tool for radiolabeling reactions involving short-lived positron emitters. Optimization of the complex array of different reaction conditions requires knowledge of the different reaction parameters linked to the microfluidic system as well as their influence on the radiochemical yields. 1-(5-Deoxy-5-fluoro-?-d-arabinofuranosyl)-2-nitroimidazole ([18F]FAZA) is a frequently used radiotracer for PET imaging of tumor hypoxia. The present study describes the radiosynthesis of [18F]FAZA by means of microfluidic technology and subsequent small animal PET imaging in EMT-6 tumor-bearing mice.Methods...

2011-01-01

36

Photo-induced transformation of close Frenkel pairs in strontium fluoride  

International Nuclear Information System (INIS)

Laser-induced change is studied of the optical absorption and luminescence due to F-H pairs generated by an electron pulse in SrF_2. It is found that laser irradiation near 2.34 eV at a delay of 26 #mu#s after an electron pulse by which F-H pairs are generated reduces the component I of the pairs that has a decay time of 59 #mu#s and optical absorption bands at 2.34 and 4.13 eV and enhances the component II that has a decay time of 7.7 ms and has optical absorption bands at 2.7 and 3.35 eV. Laser irradiation near 2.7 eV at a delay of 4 ms after the electron pulse is found to induce the reverse reaction. Studies of dichroism of the laser-induced reduction and enhancement of the optical absorption bands and the luminescence reveal that the direction of the #SIGMA#-#SIGMA# transition of the F_2"- molecular ion is converted by the transformation from I to II and vice versa. It is suggested that the component I corresponds to the F-H pairs at nearest-neighbour and II to ...

37

Influence of fluorine on the simulation of the transient enhanced diffusion of 15 keV BF{sub 2}{sup +} ion implantation into silicon  

Energy Technology Data Exchange (ETDEWEB)

We have simulated the transient enhanced diffusion (TED) of boron fluoride (BF{sub 2}{sup +}) implanted in crystalline and germanium amorphized silicon. Based on recently published models, the effect of fluorine on boron diffusion in silicon has been introduced and a modelling has been suggested. In order to simulate the boron experimental profiles, we have assumed that fluorine forms clusters involving interstitial boron which reduces the junction depth. Experimental results indicate that fluorine behaviour depends on amorphization energy. Moreover, even no germanium preamorphization is performed, silicon is still amorphized by fluorine species. Hence, BF{sub 2}{sup +} implantation leads to an amorphous/crystalline (a/c) interface near the surface. An improvement of published models is suggested taking into account fluorine effects. The simulations satisfactory reproduce the SIMS experimental profiles for a large scale of experimental conditions.

2002-01-01

38

Effect of fluoride ion on the pitting corrosion of type 304 stainless steel in neutral NaCl solution. Chusei NaCl suiyoekichu ni okeru SUS 304 ko no koshoku ni oyobosu F[sup -] no eikyo  

Energy Technology Data Exchange (ETDEWEB)

Anode polarization measurement is performed in mixed solution of NaCl and NaF using SUS 304 steel to investigate whether F[sup -] promotes or inhibits pitting corrosion. Pitting corrosion does not occur in the solution of NaF only, but passive state is broken above a certain critical potential, resulting in overall dissolution. When anode polarization measurement is made in a solution of fixed concentration NaCl added with NaF, pitting corrosion is inhibited at a certain critical concentration. F[sup -] has no effect on corrosion potential in the solution up to this critical concentration. Overall dissolution occurs in the solution with higher concentration than the critical concentration, the current value at that time agrees with that in the solution of NaF alone, and no effect of Cl[sup -] is shown. The concentration range where pitting corrosion occurs and that where overall dissolution occurs are divided by a straight line when they are expressed by logarithm of NaCl and NaF ...

1994-05-15

39

Pre-therapy 18F-FDG PET quantitative parameters help in predicting the response to radioimmunotherapy in non-Hodgkin lymphoma  

International Nuclear Information System (INIS)

Radioimmunotherapy (RIT) is a new treatment option for patients with non-Hodgkin lymphoma (NHL). Response to RIT currently remains difficult to predict using conventional prognostic factors and could be refined using functional imaging. The goal of this work is to evaluate the value of 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET) in predicting response to Yttrium 90-labeled monoclonal antibodies for patients with NHL. Thirty-five patients with NHL who had undergone 18F-FDG PET prior to RIT with either 90Y-ibritumomab tiuxetan (group A; n=17) or 90Y-epratuzumab tetraxetan (group B; n=18) were included in this retrospective study. Four functional criteria were determined for each tumour lesion in a given patient: maximum and mean standard uptake values (SUVmax and SUVmean), functional lesion volume (LVol) and total lesion glycolysis (TLG, product of the volume and the SUVmean). For each ...

2010-03-01

40

PET and MR imaging in a neuro-Behcet syndrome  

Energy Technology Data Exchange (ETDEWEB)

Positron emission tomography (PET) and magnetic resonance imaging (MRI) studies were performed on a case of neuro-Behcet's syndrome. In accordance with the clinical signs, FDG PET (using /sup 18/F-labeled 2-F-2'-desoxyglucose) revealed disseminated storage defects in the cerebrum and cerebellum. Focal regions of enhanced signal intensity were demonstrated in the parietal white matter of the cerebrum in T2-weighted images and in the brain stem by MRI. (orig.).

1989-11-01

41

Silicon effect on corrosion resistance of austenite stainless steels in strongly oxidizing media containing fluoride and phosphate admixtures  

International Nuclear Information System (INIS)

Paper estimates the corrosion resistance and studies the character of dissolving of silicon-bearing austenite stainless steels in strongly oxidizing media containing phosphate and fluoride admixtures. Corrosion behaviour of the studied steels is determined to depend essentially on the content of admixture or alloying silicon, as well as, on their phase composition in many respects determined by the thermal treatment condition. Refs. 22, figs. 1, tabs. 2.

42

Method of purifying uranium tetrafluoride hydrate and preparing uranium (VI) peroxide hydrate using a fluoride complexing agent  

International Nuclear Information System (INIS)

The annual production of phosphate rock, on the order of about 30-40 million tons yearly, represents several million pounds of uranium. The present invention provides a process of purifying uranium tetrafluoride hydrate to produce a uranium (VI) peroxide product meeting 'yellow cake' standards using a double precipitation procedure. A fluoride complexing agent is used in the precipitation.

1978-06-27

43

Catalysis over activated zeolites  

Science.gov (United States)

A process is provided for conducting organic compound conversion over a catalyst composition comprising a supported crystalline zeolite having a high initial silica-to-alumina mole ratio, said supported zeolite being prepared by compositing said crystalline zeolite with alumina, reacting the composite with a particular hydrogen fluoride solution in a specified way, drying the hydrogen fluoride reacted composite, treating the dried composite by hydrolysis, ammonolysis and/or by contact with an ammonium salt solution, and calcining the resulting material.

1985-02-19

44

Biodistribution of phenylboric acid derivative entrapped lipiodol and 4-borono-2-{sup 18}F-fluoro-L-phenylalanine-fructose in GP7TB liver tumor bearing rats for BNCT  

Energy Technology Data Exchange (ETDEWEB)

A new phenylboric acid derivative entrapped lipiodol (PBAD-lipiodol) was developed as a boron carrier for the boron neutron capture therapy (BNCT) of hepatoma in Taiwan. The biodistribution of both PBAD-lipiodol and BPA-fructose was assayed in GP7TB hepatoma-bearing rat model. The highest uptake of PBAD-lipiodol was found at 2 h post injection. The application of BNCT for the hepatoma treatment in tumor-bearing rats is suggested to be 2-4 h post PBAD-lipiodol injection.

2010-03-15

45

Spectroscopic characterization and temporal dynamics of energy transfer process between Tm{sup 3+} -Ho{sup 3+} and Yb{sup 3+} -Tm{sup 3+} ions in LiYF{sub 4} and LiLuF{sub 4} crystals; Caracterizacao espectroscopica e dinamica temporal dos processos de transferencia de energia entre os ions Tm{sup 3+} -Ho{sup 3+} e Yb{sup 3+} -Tm{sup 3+} em cristais de LiYF{sub 4} and LiLuF{sub 4}  

Energy Technology Data Exchange (ETDEWEB)

In this work, we perform spectroscopic studies to characterize the energy transfer processes occurring in rare-earth doped lithium fluoride systems, aiming the optimization of the population inversion of these media. Yb{sup 3+} ion was used in order to probe the electron-phonon coupling in LiYF{sub 4}, LiGdF{sub 4} and LiLuF{sub 4} matrices. In these systems it was obtained the average phononenergy, the vibronic transition probability and Huang-Rhys coupling constant. These parameters are dependent on the crystal host and the LiLuF{sub 4} system presents excluded correlation effects, an electronic repulsion that weakens the vibronic coupling. The Tm:Ho:LiYF{sub 4} system was studied under diode laser pumping at 796 nm, aiming the 2 {mu}m emission optimization. The ideal conditions of concentration and laser power were determined favouring the latter emission. Upconversion processes of two photons were identified besides the energy transfer ...

2001-07-01

46

System Requirements Document for the Molten Salt Reactor Experiment  

Energy Technology Data Exchange (ETDEWEB)

The purpose of the conversion process is to convert the {sup 233}U fluoride compounds that are being extracted from the Molten Salt Reactor Experiment (MSRE) equipment to a stable oxide for long-term storage at Bldg. 3019.

2000-04-01

47

Optical and mechanical properties of thermally evaporated fluoride thin films  

Energy Technology Data Exchange (ETDEWEB)

As a result of health and safety issues surrounding the use of radioactive materials on coated optical components, there has been renewed interest in coating materials whose optical and mechanical properties approach those offered by their radioactive counterparts. Due to the radioactive nature of ThF{sub 4} and its widespread use in optical coatings, the coating industry is examining other low index and non-radioactive fluorides as possible alternatives. In this paper, the authors present the results of an experimental study on the optical and mechanical properties of thermally evaporated ThF{sub 4}, DyF{sub 3}, CeF{sub 3}, LiF, HfF{sub 4}, IRX, and IRB thin films, where the materials were deposited at different substrate temperatures. The objective is to examine this series of fluorides under comparable deposition conditions and with respect to such material properties as: n and k, film stress, and environmental stability. The optical ...

1998-06-08

48

Effect of Inhibition of Acetoclastic Methanogenesis on Growth of Archaeal Populations in an Anoxic Model Environment  

UK PubMed Central (United Kingdom)

Methyl fluoride is frequently used to specifically inhibit acetoclastic methanogenesis, thus allowing determination of the relative contribution of acetate versus H2/CO2 to total...Full Text Available

2006-01-01

49

Bone scintigraphy in fluoride treated osteoporosis  

Energy Technology Data Exchange (ETDEWEB)

Quantitative bone scintigraphy was performed on 23 white females with post-menopausal osteoporosis and vertebral compression fractures. These patients were then entered into a randomized, double-blind clinical trial or sodium fluoride therapy (NaF=14, placebo=9) which included repeat bone scintigraphy every six months. Scintigraphic images were acquired for 500K counts per image over the total body with computer acquisition over the posterior thoracic and lumbar spine. Images were obtained on a wide field-of-view gamma camera two hours after injecting 15 mCi of Tc-99m MDP. Data analysis showed a significant reduction in the activity ratio of abnormal vertebral body to normal vertebral body in those patients treated with sodium fluoride (paired t-test p=0.0095). No significant change was observed in the control group of (p=0.142). These results suggest that sodium fluoride therapy promotes more rapid healing of osteoporotic ...

1985-05-01

50

Catalysis over activated high silica zeolites  

Science.gov (United States)

A process is provided for conducting organic compound conversion over a catalyst composition comprising a specially treated crystalline zeolite having a high initial silica-to-alumina mole ratio, said zeolite having been synthesized from a reaction mixture comprising a diamine as a cation source. The treatment of the zeolite material comprises the sequential steps of reacting the zeolite with a dilute hydrogen fluoride solution, contacting the hydrogen fluoride solution reacted material with aluminum chloride vapor, and then treating the aluminum chloride contacted material to convert it to hydrogen form.

1985-05-07

51

Radiopharmaceuticals labelled with positron emitting radionuclides  

International Nuclear Information System (INIS)

A brief survey is presented of the methods of preparation and of the applications of radiopharmaceuticals labelled with short-lived positron radionuclides "1"1C, "1"8F, "1"3N and "1"5O which, thanks to their energy level schemes, short half-life and the 511 keV photon radiation energy are almost ideal tracers in modern nuclear medicine and pharmacology. In conjunction with computerized tomography, they represent one of the most sensitive diagnostic imaging methods, the so-called positron emission tomography. In addition, their incorporation in the molecule of a pharmaceutical does not change the biological and chemical properties of the original molecule unlike those of radiopharmaceuticals labelled with technetium, iodine, etc. (author). 125 refs.

1989-01-01

52

Imaging pharmacodynamics in oncology. The potential significance of 'flares'  

International Nuclear Information System (INIS)

The clinical use of "1"8F-fluorodeoxyglucose (FDG) positron emission tomography in monitoring anticancer treatment is expanding. At the same time a number of radiotracers aiming to image different aspects of tumour biology such as proliferation and apoptosis are being developed. However, the factors determining changes of radiotracer uptake parameters in response to treatment are not well understood. In many cases, cellularity may be the primary determinant of changes of FDG uptake and may confound the interpretation of metabolic changes. Early imaging assessments have in some cases showed transient increases of uptake parameters, commonly termed 'flares', which are likely to be unaffected by cellularity and directly reflect pharmacodynamics at a cellular level. In this review a number of settings where molecular imaging 'flares' have been described are discussed. Such changes may often be clinically informative and warrant careful study as potential predictive biomarkers. (author)

2010-04-01

53

Thermo-transferred thermoluminescence (TTTl) in potassium-yttrium double fluoride doped with terbium  

International Nuclear Information System (INIS)

This paper presents results of studying the thermo-transferred thermoluminescence (TTTl) phenomenon in potassium-yttrium double fluoride doped with terbium (K_2YF_5_:Tb) at different impurity concentrations (0.8%, 0.95% and 0.99%). Previously to study the TTTl phenomenon, structural characterization and chemical composition of the materials were determined. The structural studies were conducted using a scanning electron microscope; meanwhile, chemical composition was analyzed using energy dispersive X-ray spectroscopy. Thermoluminescence kinetics was studied irradiating the samples with "1"3"7Cs gamma rays as well as with "9"0Sr/"9"0Y beta rays, analyzing the glow curves by the deconvolution method for obtaining the kinetic parameters. (Author)

2011-02-01

54

Reversal of brain metabolic abnormalities following treatment of AIDS dementia complex with 3'-azido-2',3'-dideoxythymidine (AZT, zidovudine): a PET-FDG study  

International Nuclear Information System (INIS)

Brain glucose metabolism was evaluated in four patients with acquired immunodeficiency syndrome (AIDS) dementia complex using ["1"8F]fluorodeoxyglucose (FDG) and positron emission tomography (PET) scans at the beginning of therapy with 3'-azido-2',3'-dideoxythymidine (AZT, zidovudine), and later in the course of therapy. In two patients, baseline, large focal cortical abnormalities of glucose utilization were reversed during the course of therapy. In the other two patients, the initial PET study did not reveal pronounced focal alterations, while the post-treatment scans showed markedly increased cortical glucose metabolism. The improved cortical glucose utilization was accompanied in all patients by immunologic and neurologic improvement. PET-FDG studies can detect cortical metabolic abnormalities associated with AIDS dementia complex, and may be used to monitor the metabolic improvement in response to AZT treatment.

55

Radiolabelled D_2 agonists as prolactinoma imaging agents: Progress report for period February 1, 1988--January 31, 1989  

International Nuclear Information System (INIS)

Targeted studies completed include the evaluation of tritiated N-0437, evaluation of "3"5S-cysteamine, evaluation of "1"8F-FDG and initiation of synthetic efforts towards the synthesis of iodinated N-0437 and pergolide analogs. The direction of the project has been changed due to several factors which include the decided lack of favorable experimental results, the excellence of results using muscarinic receptor ligands in pituitary, brain and heart and the contention of the DOE review panel that the original grant proposal was based on flawed assumptions together with their perceived lack of importance to pituitary imaging. In the final year of this grant, three studies will be completed. The first study is the continuation of synthetic efforts to prepare iodinated N-0437 and pergolide analogs for possible use as brain imaging agents. The second study is directed towards completion of biochemical evaluation of various muscarinic receptor analogs for heart, brain and (possible) ...

56

Radiolabelled D/sub 2/ agonists as prolactinoma imaging agents: Progress report for period February 1, 1988--January 31, 1989  

Energy Technology Data Exchange (ETDEWEB)

Targeted studies completed include the evaluation of tritiated N-0437, evaluation of /sup 35/S-cysteamine, evaluation of /sup 18/F-FDG and initiation of synthetic efforts towards the synthesis of iodinated N-0437 and pergolide analogs. The direction of the project has been changed due to several factors which include the decided lack of favorable experimental results, the excellence of results using muscarinic receptor ligands in pituitary, brain and heart and the contention of the DOE review panel that the original grant proposal was based on flawed assumptions together with their perceived lack of importance to pituitary imaging. In the final year of this grant, three studies will be completed. The first study is the continuation of synthetic efforts to prepare iodinated N-0437 and pergolide analogs for possible use as brain imaging agents. The second study is directed towards completion of biochemical evaluation of various muscarinic ...

1988-10-15

57

Nitroimidazole conjugates of bis(thiosemicarbazonato)64Cu(II) - Potential combination agents for the PET imaging of hypoxia  

British Library Electronic Table of Contents (United Kingdom)

Combination agents comprising two different pharmacophores with the same biological target have the potential to show additive or synergistic activity. Bis(thiosemicarbazonato)copper(II) complexes (e.g. 64Cu-ATSM) and nitroimidazoles (e.g. 18F-MISO) are classes of tracer used for the delineation of tumor hypoxia by positron emission tomography (PET). Three nitroimidazole-bis(thiosemicarbazonato)copper(II) conjugates were produced in order to investigate their potential as combination hypoxia imaging agents. Two were derived from the known bifunctional bis(thiosemicarbazone) H2ATSM/A and the third from the new precursor diacetyl-2-(4-N-methyl-3-thiosemicarbazone)-3-(4-N-ethylamino-3-thiosem icarbazone) - H2ATSM/en. Oxygen-dependent uptake studies were performed using the 64Cu radiolabelled ...

2010-01-01

58

Application of 18F-fluorodeoxyglucose positron emission tomography to detection of proximal lesions of obstructive colorectal cancer  

International Nuclear Information System (INIS)

In cases of obstructive colorectal cancer (CRC), preoperative diagnosis of the proximal lesion is often difficult when the primary lesion impedes the passage of the endoscope. The aim of this study was to evaluate the usefulness of fluorine-18-fluorodeoxyglucose positron emission tomography (FDG-PET) in such cases. A total of 52 obstructive CRC patients who underwent preoperative FDG-PET and subsequent surgical resection were retrospectively reviewed. The correlation between characteristics of the proximal lesion and FDG-PET findings was analyzed statistically. There was a significant correlation between the proximal lesion size and the maximum standardized uptake value (P=0.00016). Abnormal FDG accumulation in the proximal colon indicated the existence of proximal cancer or adenoma with a sensitivity of 50% and a specificity of 100%. There was a significant difference in the distribution of tumor size between the cases with proximal abnormal accumulation and those with no proximal ...

2010-10-01

59

Regulation of the phosphoinositide pathway in cultured Sertoli cells from immature rats: effects of follicle-stimulating hormone and fluoride  

International Nuclear Information System (INIS)

Many hormones elicit effects on target cells by stimulating the enzyme phospholipase-C, which catalyzes the hydrolysis of phosphoinositides to the intracellular second messengers diacylglycerol and inositol phosphates. The present study examined the roles of FSH and guanine nucleotide-binding proteins (G-proteins) in regulating the hydrolysis of phosphoinositides in Sertoli cells. Sertoli cell cultures prepared from 16- to 18-day-old rats were incubated for 24 h with myo-[2-3H] inositol to label endogenous phospholipids. Treatment of cells from 0.5-20 min with preparations of ovine FSH ranging in potency from 1-60 times that of NIH FSH S1 did not affect accumulation of inositol phosphates. Levels of total [3H]inositol phosphates [[3H]inositol mono-, di-, and triphosphates (IP, IP2, and IP3)] in FSH-treated cultures was 75-120% the levels in control cultures over the various time intervals studied. Addition of testosterone and the combination of testosterone plus retinoic acid, agents ...

60

Radiation doses and somatic risk to patients during cardiac radiological procedures  

International Nuclear Information System (INIS)

The radiation dose to a series of adult and paediatric patients undergoing cardiac catheterisations and adults having percutaneous transluminal coronary angioplasty has been measured/determined directly using lithium fluoride thermoluminescent dosemeters and indirectly using an air ionisation chamber which indicated exposure-area product. Somatic and genetic risks are estimated from the dosimetry results. It is suggested that the magnitude of the radiation hazard is negligible compared with other clinical hazards associated with these procedures. (author).

1986-01-01

61

Effect of acidic fluoride solution on beta titanium alloy wire.  

Science.gov (United States)

The interaction between acidic fluoride solution and beta titanium alloy was investigated to explore the changes that occur in beta titanium alloy by fluoride-containing acetic acid solutions. For this, alloy crystal structure, tensile strength, and elements released from the alloy wires were determined using four solutions (0.05%/pH 6, 0.05%/pH 4, 0.2%/pH 6, and 0.2%/pH 4) for 1 or 3 days. The immersed wire did not form any identifiable new crystal structure compared with the as-received wire. The tensile strength of the immersed wires was significantly reduced compared to the as-received wires in the test solutions if the period of immersion increased from as-received to 3 days. The fractured area of the immersed wire was reduced compared to the as-received one. The dimple pattern at the inner part and a cup-cone morphology at the outer part of the fractured wires were similar in both as-received and immersed wires. After a 3-day immersion, ...

2005-05-01

63

Method and apparatus for efficient photodetachment and purification of negative ion beams  

Energy Technology Data Exchange (ETDEWEB)

Methods and apparatus are described for efficient photodetachment and purification of negative ion beams. A method of purifying an ion beam includes: inputting the ion beam into a gas-filled multipole ion guide, the ion beam including a plurality of ions; increasing a laser-ion interaction time by collisional cooling the plurality of ions using the gas-filled multipole ion guide, the plurality of ions including at least one contaminant; and suppressing the at least one contaminant by selectively removing the at least one contaminant from the ion beam by electron photodetaching at least a portion of the at least one contaminant using a laser beam.

2008-02-26

64

Inelastic collisions of molecular ions in the injected ion drift tube  

International Nuclear Information System (INIS)

... energy spectra inelastic scattering ion-molecule collisions mass spectrometers

1977-07-27

69

Radiation damage and recovery in the light emittance efficiency and the attenuation length of barium fluoride scintillator  

International Nuclear Information System (INIS)

Radiation damage and its recovery in the light emittance efficiency and the attenuation length of barium fluoride (BaF_2) scintillator have been investigated. The light yield and transmittance of small samples of BaF_2 scintillator were measured after #gamma#-irradiation from 0.5x10"4 to 1.1x10"5 Gy for deterioration, and after sunlight exposure for recovery. Suspension of deterioration was observed both in light yield and in attenuation length at an integrated dose of #gamma#-rays of about 10"4 Gy. Fairly good and quick recovery of the deteriorated BaF_2 scintillator was obtained by sunlight exposure. Using a Monte Carlo simulation method, the dependence of the light emittance efficiency on #gamma#-irradiation and sunlight exposure was studied. It has been found that the light emittance efficiency, as well as the attenuation length, is influenced by #gamma#-irradiation and sunlight exposure. (orig.).

70

Large area electron beam pumped krypton fluoride laser amplifier  

International Nuclear Information System (INIS)

Nike is a recently completed multi-kilojoule krypton fluoride (KrF) laser that has been built to study the physics of direct drive inertial confinement fusion. This paper describes in detail both the pulsed power and optical performance of the largest amplifier in the Nike laser, the 60 cm amplifier. This is a double pass, double sided, electron beam-pumped system that amplifies the laser beam from an input of 50 J to an output of up to 5 kJ. It has an optical aperture of 60 cm x 60 cm and a gain length of 200 cm. The two electron beams are 60 cm high x 200 cm wide, have a voltage of 640 kV, a current of 540 kA, and a flat top power pulse duration of 250 ns. A 2 kG magnetic field is used to guide the beams and prevent self-pinching. Each electron beam is produced by its own Marx/pulse forming line system. The amplifier has been fully integrated into the Nike system and is used on a daily basis for laser-target experiments. copyright 1997 American Institute of ...

71

Kinetic investigations of graft copolymerization of sodium styrene sulfonate onto electron beam irradiated poly(vinylidene fluoride) films  

Energy Technology Data Exchange (ETDEWEB)

Graft copolymerization of sodium styrene sulfonate (SSS) onto electron beam (EB) irradiated poly(vinylidene fluoride) (PVDF) films was investigated to find out a simple preparation process for sulfonic acid proton exchange membranes with respect to monomer concentration, absorbed dose, temperature, film thickness and storage time. The reaction order of the monomer concentration and absorbed dose of grafting was found to be 2.84 and 1.20, respectively. The overall activation energy for graft copolymerization reaction was calculated to be 11.36 kJ/mol. The initial rate of grafting was found to decrease with an increase in the film thickness. The trapped radicals in the irradiated PVDF films remained effective in initiating the reaction without considerable loss in grafting level up to 180 days, when stored under -60 {sup o}C. The presence and distribution of polystyrene sulfonate grafts in the obtained membranes were observed by Fourier transform infrared (FTIR) ...

2011-01-15

72

Influence of potassium fluoride on the syntheses of methylpiperazine-modified poly(vinyl chloride)s for use as fixed-site proton carrier membranes.  

Science.gov (United States)

Aminated poly(vinyl chloride) (PVC) membranes were prepared that had a Nernstian response over a wide range of pH. The reaction between PVC and methyl-piperazine (MePIP) in dimethylformamide (DMF) was studied over a wide range of time and temperature, and in the presence of the catalyst, potassium fluoride (KF). Time, temperature, and KF increased the nitrogen (N) content of the resulting polymers, but sometimes at the expense of decreasing their specific viscosities (molecular weights). Activation energies of processes that occurred in different temperature ranges were estimated assuming an Arrhenius relationship. A Nernstian response occurred once the N content approached to about 0.3 w/w %, and was accelerated by the presence of KF at elevated temperatures. Increasing the N content above about 3% led to a loss of the Nernstian response either because of an increase in the double bond content and a subsequent decrease in polymer mobility, or because of a decrease ...

1998-03-15

73

Friction properties of WS{sub 2}/graphite fluoride thin films grown by pulsed laser deposition  

Energy Technology Data Exchange (ETDEWEB)

Graphite fluoride (CF{sub x}) is investigated as an additive for WS{sub 2} thin films to reduce its sensitivity to moisture. The films are grown onto hardened 440C stainless steel disks by pulsed laser deposition using the 248 nm line from an excimer laser. Substrate temperature and additive concentration are varied to control film chemistry and crystal structure. The effect of relative humidity (i.e., < 1 to 85% RH) on friction is evaluated. Coatings grown at RT from targets with a low concentration of CF{sub x} exhibit ultra-low friction (ULF) behavior in dry air (i.e., {mu} {<=} 0.01), but friction increases with RH. Mechanisms for the ULF behavior are proposed which suggest that further reductions in friction are possible. Films grown at 300 C or with higher concentrations of CF{sub x} are relatively insensitive to humidity, but have more typical friction coefficients ({mu} {<=} 0.04) in dry air. (orig.)

1995-12-01

74

Fluorimetric determination of uranium in certain refractory minerals, environmental samples and industrial waste materials  

International Nuclear Information System (INIS)

A simple sample decomposition and laser fluorimetric determination of uranium at trace level is reported in certain refractory minerals, like ilmenite, rutile, zircon and monazite; environmental samples viz. soil and sediments; industrial waste materials, such as, coal fly ash and red mud. Ilmenite sample is decomposed by heating with ammonium fluoride. Rutile, zircon and monazite minerals are decomposed by fusion using a mixture of potassium bifluoride and sodium fluoride. Environmental and industrial waste materials are brought into solution by treating with a mixture of hydrofluoric and nitric acids. The laser induced fluorimetric determination of uranium is carried out directly in rutile, zircon and in monazite minerals and after separation in other samples. The determination limit was 1 #mu#g x g"-"1 for ilmenite, soil, sediment, coal fly ash and red mud samples, and it is 5 #mu#g x g"-"1 for rutile, zircon and monazite. The method is also ...

2005-10-01

75

Electrochemical corrosion behavior of AZ91D alloy in ethylene glycol  

Energy Technology Data Exchange (ETDEWEB)

The effect of concentration on the corrosion behavior of Mg-based alloy AZ91D was investigated in ethylene glycol-water solutions using electrochemical techniques i.e. potentiodynamic polarization, electrochemical impedance measurements (EIS) and surface examination via scanning electron microscope (SEM) technique. This can provide a basis for developing new coolants for magnesium alloy engine blocks. Corrosion behavior of AZ91D alloy by coolant is important in the automotive industry. It was found that the corrosion rate of AZ91D alloy decreased with increasing concentration of ethylene glycol. For AZ91D alloy in chloride >0.05 M or fluoride <0.05 M containing 30% ethylene glycol solution, they are more corrosive than the blank (30% ethylene glycol-70% water). However, at concentrations <0.05 for chloride or >0.05 M for fluoride containing ethylene glycol solution, some inhibition effect has been observed. The ...

2009-11-01

76

Electrochemical corrosion behavior of AZ91D alloy in ethylene glycol  

International Nuclear Information System (INIS)

The effect of concentration on the corrosion behavior of Mg-based alloy AZ91D was investigated in ethylene glycol-water solutions using electrochemical techniques i.e. potentiodynamic polarization, electrochemical impedance measurements (EIS) and surface examination via scanning electron microscope (SEM) technique. This can provide a basis for developing new coolants for magnesium alloy engine blocks. Corrosion behavior of AZ91D alloy by coolant is important in the automotive industry. It was found that the corrosion rate of AZ91D alloy decreased with increasing concentration of ethylene glycol. For AZ91D alloy in chloride >0.05 M or fluoride 0.05 M for fluoride containing ethylene glycol solution, some inhibition effect has been observed. The corrosion of AZ91D alloy in the blank can be effectively inhibited by addition of 0.05 mM paracetamol that reacts with AZ91D alloy and forms a protective film on the surface at this concentration as ...

2009-11-01

77

Cf-source-driven neutron-noise measurements of subcriticality for a 4. 95 wt% /sup 235/U-enriched uranyl fluoride solution cylinder  

Energy Technology Data Exchange (ETDEWEB)

A method for determining the reactivity of subcritical systems of fissile material, using neutron-noise power spectral density measurements in conjunction with a /sup 252/Cf source, has been tested in experiments with an aqueous solution containing uranium fluoride (4.95 wt% /sup 235/U). The kappasub(eff)-values obtained from the ratio of spectral densities G*/sub 12/G/sub 13//G/sub 11/G/sub 23/ agreed with those from break-frequency noise analysis and with bias-corrected transport theory calculations within the statistical uncertainty of the measurements. Corrections for the effects of spatial modes and source-detector locations appear to be well-understood, since measurements for a variety of source-detector positions resulted in essentially the same kappasub(eff)-values. Modal correction factors were such that ignoring them would result in higher values of kappasub(eff) than actually occur. The measurements have demonstrated the applicability of the /sup ...

1986-01-01

78

Analyses of postulated accidental releases of UF6 inside process buildings  

International Nuclear Information System (INIS)

Uranium Hexafluoride is a material used in the various processes which comprise the front end of the nuclear fuel cycle (conversion, enrichment and fuel fabrication). Confinement of UF6 is a very important safety requirement since this material is highly reactive and presents safety hazards to humans. The present paper discusses the safety relevant aspects of accidental releases of UF6 inside process confinement buildings. Postulated accidental scenarios are analyzed and their consequences evaluated. Implant releases rates are estimated using computer code predictions. A time dependent homogeneous compartment model is used to predict concentrations of UF6, hydrogen fluoride and uranyl fluoride inside a confinement building, as well as to evaluate source terms released to the atmosphere. These source terms can be used as input to atmospheric dispersion models to evaluate consequences to the environment. The results can also be used to define ...

79

Process for the chemical removal of ash from coal and device for carrying out this process. Verfahren zur chemischen Entfernung der Asche aus Kohle sowie Vorrichtungen zur Durchfuehrung dieses Verfahrens  

Energy Technology Data Exchange (ETDEWEB)

In order to remove ash from coal, it is introduced into an aqueous ash removal solution, which contains nitric acid or citric acid and ammonium hydrogen fluoride. The coal without ash is then separated from the aqueous solution. According to the process, either finely ground coal is introduced into the ash removel solution or the coal with the solution is ground in a wet pulveriser.

1981-03-13

80

Passivation-free solid state battery  

Energy Technology Data Exchange (ETDEWEB)

This invention pertains to passivation-free solid-state rechargeable batteries composed of Li.sub.4 Ti.sub.5 O.sub.12 anode, a solid polymer electrolyte and a high voltage cathode. The solid polymer electrolyte comprises a polymer host, such as polyacrylonitrile, poly(vinyl chloride), poly(vinyl sulfone), and poly(vinylidene fluoride), plasticized by a solution of a Li salt in an organic solvent. The high voltage cathode includes LiMn.sub.2 O.sub.4, LiCoO.sub.2, LiNiO.sub.2 and LiV.sub.2 O.sub.5 and their derivatives.

1998-01-01

81

Passivation-free solid state battery  

Energy Technology Data Exchange (ETDEWEB)

This invention pertains to passivation-free solid-state rechargeable batteries composed of Li{sub 4}Ti{sub 5}O{sub 12} anode, a solid polymer electrolyte and a high voltage cathode. The solid polymer electrolyte comprises a polymer host, such as polyacrylonitrile, poly(vinyl chloride), poly(vinyl sulfone), and poly(vinylidene fluoride), plasticized by a solution of a Li salt in an organic solvent. The high voltage cathode includes LiMn{sub 2}O{sub 4}, LiCoO{sub 2}, LiNiO{sub 2} and LiV{sub 2}O{sub 5} and their derivatives. 5 figs.

1998-06-16

82

Fluoride induced changes in protein metabolism in the tissues of freshwater crab Barytelphusa guerini.  

Science.gov (United States)

Exposure of the freshwater field crab Barytelphusa guerini to a sublethal concentration of NaF (30 mg litre(-1)) caused significant alterations in protein metabolism. After an exposure time of 15 days, the crab was found to have a marked depletion of total protein and free amino acid content. A significant elevation in transaminases, Aspartate aminotransferase (AAT) and Alanine aminotransferase (ALAT), and Glutamate dehydrogenase (GDH) activities was reflected in the free amino acid levels of the tissues. PMID:15092215

1990-01-01

83

Fatalities resulting from sulfuryl fluoride exposure after home fumigation-Virginia  

Energy Technology Data Exchange (ETDEWEB)

On September 25, 1986, an elderly Virginia couple had their home fumigated by a local pest extermination company for the control of wood-boring insects. Two hundred and fifty pounds of sulfurylfluoride (SF), a colorless, odorless fumigant gas commonly used for this purpose, was applied in the approximately 80,000-cubic-foot home that date. Within 1 week, both husband and wife were dead. Because both deaths occurred within a short period of time and the wife's illness was compatible with toxic gas inhalation, these deaths were then thought to be related to the home fumigation.

1987-10-16

84

Environmental radiation measurements using TLD in and around AERE, Dhaka. Technical note  

Energy Technology Data Exchange (ETDEWEB)

The external background radiation level in and around the Atomic Energy Research Establishment (AERE) in Dhaka has been measured. The measurements were performed using lithium fluoride (LiF) thermoluminescence dosemeters (TLD-100) at 32 locations, all one metre above the ground. The annual average dose rate measured in the AERE environs was 1.74+-0.23 mGy.y/sup -1/ in air, based on analysis of thermoluminescence dosemeter data collected from 1982 to 1984.

1986-01-01

85

Conception, realization and test of an electronic Si-LiF-Si sensor for neutron spectrometry and dosimetry  

International Nuclear Information System (INIS)

The aim of this thesis is the study of new systems devoted to the real time neutron spectrometry and dosimetry. The microelectronics technologies have been used to research a micro system integrating sensor and data processing in real time. The multi range sensor is based on many pair of semiconductor diodes placed face to face and covered by lithium fluoride. The sensor has been designed and its behavior has been simulated. Its operating in reference neutrons beams has been analyzed. (A.L.B.)

1998-01-01

86

Conceptual Design of Superconducting Quadrupole Arrays for the Heavy-Ion Fusion  

CERN Document Server

Conceptual Design of Superconducting Quadrupole Arrays for the Heavy-Ion Fusion

1999-01-01

87

Compact Proton and Carbon Ion Synchrotrons for Radiation Therapy  

CERN Document Server

Compact Proton and Carbon Ion Synchrotrons for Radiation Therapy

2002-01-01

88

Usefulness of "1"8F-FDG PET in intrahepatic cholangiocarcinoma  

International Nuclear Information System (INIS)

Surgical resection is the only curative treatment strategy for intrahepatic cholangiocarcinoma (CC). Therefore, accurate staging is essential for appropriate management of patients with CC. We assessed the usefulness of 2-["1"8F]fluoro-2-deoxy-d-glucose (FDG) positron emission tomography (PET) in the staging of CC. We undertook a retrospective review of FDG PET images in 21 patients (10 female, 11 male; mean age 57 years) diagnosed with CC. Ten patients had hilar CC and 11, peripheral CC. Patients underwent abdominal magnetic resonance imaging (MRI) (n=20) and computed tomography (CT) (n=12) for the evaluation of primary tumours, and chest radiography and whole-body bone scintigraphy for work-up of distant metastases. For semi-quantitative analysis, the maximum voxel standardised uptake value (SUV_m_a_x) was obtained from the primary tumour. All peripheral CCs showed intensely increased FDG uptake, and some demonstrated ring-shaped uptake corresponding to peripheral rim enhancement on ...

2003-11-01

89

The present state of nuclear medicine practice in Japan; A report of the 3rd nationwide survey in 1992  

Energy Technology Data Exchange (ETDEWEB)

The Subcommittee for Surveillance of Nuclear Medicine Practice has implemented a survey for actual nuclear medicine practice in Japan every 5 years. This article reports on the third survey implemented during a one-month period in June 1992. Questionnaires were sent to all 1256 facilities employing radiopharmaceuticals in routine practice, and 1162 (92.5%) answered. In vivo nuclear medicine examinations per day were performed in 6600 cases. SPECT accounted for 19.4%, as compared with 7.1% in the 1987 survey. According to organs, the frequency of examination for the cerebrospinal region was 3.2 and 2.2 times higher than that in the 1982 and 1987 surveys, respectively, whereas for the thyroid gland it was 0.6-fold and 0.7-fold that of these surveys. The proportion of bone scintigraphy was the highest (24.5%), followed by tumor scintigraphy (14.1%) and myocardial scintigraphy (11.9%). The frequency of myocardial and cerebral blood flow scintigraphy was dramatically increased as compared ...

1993-09-01

90

Kinetic analysis of transport and opioid receptor binding of ( sup 3 H)(-)-cyclofoxy in rat brain in vivo: Implications for human studies  

Energy Technology Data Exchange (ETDEWEB)

(3H)Cyclofoxy (CF: 17-cyclopropylmethyl-3,14-dihydroxy-4,5-alpha-epoxy-6-beta-fluoromorp hinan) is an opioid antagonist with affinity to both mu and kappa subtypes that was synthesized for quantitative evaluation of opioid receptor binding in vivo. Two sets of experiments in rats were analyzed. The first involved determining the metabolite-corrected blood concentration and tissue distribution of CF in brain 1 to 60 min after i.v. bolus injection. The second involved measuring brain washout for 15 to 120 s following intracarotid artery injection of CF. A physiologically based model and a classical compartmental pharmacokinetic model were compared. The models included different assumptions for transport across the blood-brain barrier (BBB); estimates of nonspecific tissue binding and specific binding to a single opiate receptor site were found to be essentially the same with both models. The nonspecific binding equilibrium constant varied modestly in different brain structures (Keq = ...

1991-03-01

91

Measurement of oxidation rate of sulfite in rain water in Yokohama, Japan  

Energy Technology Data Exchange (ETDEWEB)

In recent years, the influences of acid rain such as the acidification of lake water, on bio-system by the heavy metals from effluent of soils with acid rain and also on the structural materials of buildings are seriously discussed. Sulfur and nitrogen that are contained in fossil fuels are released into the atmosphere by the fuel combustion as their oxides dissolve in rain drops as sulfite and nitrous ions, where they are further oxidized into sulfate and nitrate ions These ions lower the pH of rain water resulting so-called acid rain. Therefore, it is important to accurately determine these ions in rain water for the investigation of reality of acid rain. However, it is not easy to accurately determine these ions, especially for sulfite ions in rain water, since they are quickly oxidized by the catalytic action of metallic ions such as ...

1986-04-01

92

The physics of Electron Beam Ion Sources  

Energy Technology Data Exchange (ETDEWEB)

There are 13 Electron Beam Ion Sources in operation which produce highly charged ions, up to Th[sup 80+] and Xe[sup 53+]. Most of the sources are used to study these ions under electron impact or when recombining with gaseous or solid targets. That provides an insight into the atomic physics of these highly charged ions and into the physics of the plasma in which such ions can be found. This paper reviews the present knowledge of atomic processes, important in the production of such ions with an EBIS.

1990-01-01

93

The physics of Electron Beam Ion Sources  

Energy Technology Data Exchange (ETDEWEB)

There are 13 Electron Beam Ion Sources in operation which produce highly charged ions, up to Th{sup 80+} and Xe{sup 53+}. Most of the sources are used to study these ions under electron impact or when recombining with gaseous or solid targets. That provides an insight into the atomic physics of these highly charged ions and into the physics of the plasma in which such ions can be found. This paper reviews the present knowledge of atomic processes, important in the production of such ions with an EBIS.

1990-12-31

94

Formation of charge and energy distribution of heavy ions in substance according to diffusion model  

International Nuclear Information System (INIS)

The formation of the ions charge and energy distributions of the ions slowed down or randomly changing their charge in the collisions with the medium particles are studied. The effect of the ions dispersion by the charge on the Bragg curve form is investigated. The proposed diffusion approximation for the heavy ions kinetic equation makes it possible to determine simply the parameters of the ions distribution by charge and energy on the whole way of the ions motion. The relation between the ions charge distribution characteristics and the cross sections of the ionization-recombination processes is indicated. The ions distributions, calculated in the proposed analytical model, are compared with the results of the numerical calculations. Good agreement between the analytical, numerical and experimental results is obtained

2003-11-01

95

Ion Langmuir waves in a nonneutral plasma  

Energy Technology Data Exchange (ETDEWEB)

A nonneutral /sup 7/Li/sup +/ ion plasma is described in which ion Langmuir waves are observed for the first time. The properties of these waves near the Brillouin density limit are investigated.

1981-01-05

96

Surface modification on magnesium alloys by coating with magnesium fluorides  

Energy Technology Data Exchange (ETDEWEB)

A new technique has been developed for improving corrosion resistance on magnesium alloys. Specimens of AZ31 magnesium alloy were dipped into molten salt of NaBF{sub 4} at 723 K for various times, and then cooled, rinsed with water, and dried in air. Corrosion resistance in the surface treated specimens was evaluated by salt immersion test using 1% NaCl solution as a time for occurring filiform corrosion. On an un-treated AZ31 alloy, the time for starting the filiform corrosion was about 1.2 ks, while on the surface treated specimen, the time was prolonged into about 1300 ks. Moreover, the surface treated specimen showed corrosion resistance in low pH solutions, such as 1% HNO{sub 3} and HCl solutions. (orig.)

2005-07-01

97

Study on the interface of PVDF coatings and HF-treated AZ31 magnesium alloy: Determination of interfacial interactions and reactions with self-healing properties  

International Nuclear Information System (INIS)

Research highlights: ? Reports a high protection system for the alloy in corrosive environment. ? Describes an interfacial process with self-healing properties. ? Reports the influence of substrate pre-treatment in the coating performance. - Abstract: In this paper the interface of poly(vinylidene fluoride) coatings prepared by the dip coating method and HF-treated AZ31 magnesium alloy was evaluated. The best performance of this system in corrosion tests compared to ground, as-received and acetic acid cleaned substrates is related to an acid-base interaction at the interface and to interfacial reactions which resulted in a self-healing process. The protectiveness of the samples was investigated using impedance and immersion tests while the coating morphology and interface stability were investigated by scanning electron microscopy, X-ray photoelectron spectroscopy and adhesion tests.

2011-02-01

98

LiF enhanced nucleation of the low temperature microcrystalline silicon prepared by plasma enhanced chemical vapour deposition  

Energy Technology Data Exchange (ETDEWEB)

A 15-nm lithium fluoride (LiF) thin film evaporated on glass substrate is shown to enhance the nucleation of microcrystalline Si grown by plasma enhanced chemical vapour deposition at the amorphous/microcrystalline boundary conditions. The effect is more pronounced at low substrate temperatures, nucleation density being 10 times higher at {approx} 80 {sup o}C. The effect is ascribed to the ionic chemical nature of LiF, the low work function material used in organic electronic devices, and we propose its use for micro patterning crystalline Si regions in otherwise amorphous Si film.

2009-10-30

99

Effect of Coating of Ammonium Perchlorate with Fluorocarbon on Ballistic and Sensitivity Properties of AP/Al/HTPB Propellant  

British Library Electronic Table of Contents (United Kingdom)

Fluorocarbon polymers are used to enhance thermal stability and electrostatic protection of composite propellant compositions. A precipitation technique has been developed to coat ammonium perchlorate (AP) using a copolymer of hexafluoropropylene and vinylidene fluoride (HFP-VF) with the help of solvent-counter solvent method. The coated AP has been used to prepare propellant compositions in different ratio based on hydroxyl terminated polybutadiene (HTPB), aluminium powder along with uncoated AP and studied for viscosity build-up and visco-elastic behaviour as well as mechanical, ballistic, thermal and sensitivity properties keeping 86% solid loading. The data on viscosity build-up indicate that as the percentage of viton coated AP increases end of mix viscosity and viscosity build-up inc...

2009-01-01

100

Chemical aspects of the trapping and recovery of uranium hexafluoride and fluorine during remediation activities  

Energy Technology Data Exchange (ETDEWEB)

Decontamination and decommission activities related to the Molten Salt Reactor Experiment (MSRE) involve the trapping and recovery of radiolitically generated uranium hexafluoride and fluorine. Although fission product radiolysis was known to generate F{sub 2}, the formation of UF{sub 6} and its transport from the fuel salt was unexpected. Some of these gaseous radiolysis products have been moving through the gas piping to a charcoal bed since the reactor was shut down in 1969. Current and planned remediation and clean-up activities involve the trapping of the gaseous products, deactivation and treatment of the activated charcoal bed, stabilization and reconditioning of the fuel salt, and recovery of the uranium. The chemical aspects of these processes, including radiolytic generation mechanisms, reactions between uranium hexafluoride and fluorine and trapping materials such as activated charcoal, activated alumina, and sodium fluoride, along with the analytical ...

1996-10-01

101

A comparison of patient doses in lumbar spine radiography from various X-ray units in Poland  

Energy Technology Data Exchange (ETDEWEB)

A number of diagnostic X-ray units in Poland were subjected to analysis. The air kerma on X-ray tables was measured for the X-ray parameters used routinely during lumbo-sacral spine radiography of standard adult patient. Measurements of air kerma were performed using TLD made of lithium-fluoride. The doses received by patients in different X-ray departments can differ more than two orders of magnitude (from 0.42 mGy up to 72.11 mGy), for the same X-ray examination. The dose can be significantly reduced if fluorescent screens made from components of rare earth are used. (author). 10 refs, 1 fig., 2 tabs.

1995-12-31

105

Electron detachment cross-sections and secondary-electron emission factors for heavy-negative-ion beams  

Energy Technology Data Exchange (ETDEWEB)

The properties of negative-ion beams are very important for designing negative-ion apparatus and applications of negative-ion beams, especially, electron detachment cross-sections at the interaction between negative-ion beams and gas particles in the transport system, and secondary-electron emission factors when negative ions are incident on solid surfaces. These properties of negative-ion beams were investigated experimentally as a function of the ion energy under 50 keV. The single electron detachment cross-sections are almost constant in the other of 10[sup -15] cm[sup 2] in this energy range, but double electron detachment cross-sections increase in proportion to the ion velocity and much smaller than the single one. As for the secondary-electron emission factor, the emission factors for ...

1994-01-01

106

Electron detachment cross-sections and secondary-electron emission factors for heavy-negative-ion beams  

International Nuclear Information System (INIS)

The properties of negative-ion beams are very important for designing negative-ion apparatus and applications of negative-ion beams, especially, electron detachment cross-sections at the interaction between negative-ion beams and gas particles in the transport system, and secondary-electron emission factors when negative ions are incident on solid surfaces. These properties of negative-ion beams were investigated experimentally as a function of the ion energy under 50 keV. The single electron detachment cross-sections are almost constant in the other of 10"-"1"5 cm"2 in this energy range, but double electron detachment cross-sections increase in proportion to the ion velocity and much smaller than the single one. As for the secondary-electron emission factor, the emission factors for negative-ion ...

1994-01-01

108

Heavy-ion accelerators and predicted lifetimes of highly stripped ions  

International Nuclear Information System (INIS)

(Sep 1973). United Kingdom Sinanoglu, O. Luken, W. Yale Univ., New Haven,

1973-01-01

110

Recent status of the development of intense ion beams  

Energy Technology Data Exchange (ETDEWEB)

Taking the development of large current, negative ion sources which is in progress aiming at nuclear fusion reactors and the development of high luminance ion sources planned as a part of the Omega Project as the examples, the technology for generating high power ion beams is explained. Both these projects are positioned at the limit of the present technology of high power ion beam application as their targeted beam power reaches several tens MW. Consequently, the requirement for the ion sources is severe, and in particular, the generation of the ion beams having large current density with good convergence is beyond all precedents. The application of high power ion sources has been realized as the neutral beam injectors for large tokamaks. Also the hydrogen negative ion source of large current and the electrostatic ...

1993-12-01

111

Electrochemical behavior of Ti-Cr alloys in artificial saliva  

Energy Technology Data Exchange (ETDEWEB)

In this study, the corrosion behavior of commercially pure titanium (c.p. Ti), Ti-6Al-4V and five new experimental Ti-Cr alloys was evaluated through open-circuit potential (OCP) and potentiodynamic polarization measurement in an artificial saliva containing fluoride. Electron spectroscopy for chemical analysis (ESCA) was used to characterize the composition of the passive films on the alloy after potentiodynamic polarization measurement. It was found that in standard artificial saliva the OCP increases with higher Cr content in Ti-Cr alloys. In 0.5% NaF artificial saliva, the OCP decreases with decreasing Cr in Ti-Cr alloys, and all but Ti-5Cr remain consistently higher than those of c.p Ti and Ti-6Al-4V. Linear polarization results show that artificial saliva and artificial saliva containing 0.5% NaF result in different corrosion behavior in Ti-Cr alloys, c.p.Ti and Ti-6Al-4V. The Ti-Cr alloys had greater resistance to corrosion in the ...

2009-11-13

112

Electrochemical behavior of Ti-Cr alloys in artificial saliva  

International Nuclear Information System (INIS)

In this study, the corrosion behavior of commercially pure titanium (c.p. Ti), Ti-6Al-4V and five new experimental Ti-Cr alloys was evaluated through open-circuit potential (OCP) and potentiodynamic polarization measurement in an artificial saliva containing fluoride. Electron spectroscopy for chemical analysis (ESCA) was used to characterize the composition of the passive films on the alloy after potentiodynamic polarization measurement. It was found that in standard artificial saliva the OCP increases with higher Cr content in Ti-Cr alloys. In 0.5% NaF artificial saliva, the OCP decreases with decreasing Cr in Ti-Cr alloys, and all but Ti-5Cr remain consistently higher than those of c.p Ti and Ti-6Al-4V. Linear polarization results show that artificial saliva and artificial saliva containing 0.5% NaF result in different corrosion behavior in Ti-Cr alloys, c.p.Ti and Ti-6Al-4V. The Ti-Cr alloys had greater resistance to corrosion in the ...

2009-11-13

113

Role of positron emission tomography-computed tomography in staging and early chemotherapy response evaluation in children with neuroblastoma  

International Nuclear Information System (INIS)

To evaluate the role of positron emission tomography-computed tomography (PET-CT) in staging and determining early treatment response to chemotherapy in children with neuroblastoma (NB) and its correlation with the final outcome. Patients and Methods: Seventeen patients of NB with mean age of 51.5 months (age range 2-132 months; 14 males, 3 females) underwent serial "1"8F-fluorodeoxyglucose (FDG) PET-CT imaging. All 17 patients were for staging before any treatment. Twelve of 17 patients underwent "1"3"1I meta-iodobezylguanidine (MIBG) scan and bone scan. MIBG uptake was seen in the primary lesion in 11/12 patients. MIBG uptake in bones was seen in 3/12 patients. All bone lesions were concordant on MIBG and bone scan. Early response to chemotherapy was evaluated after two cycles using PET-CT. A 30% reduction in longest diameter was taken as cut-off value for response on CT based on the response evaluation criteria in solid tumors criteria. Response on PET-CT was assessed using ...

114

Development of a high current negative ion source for fusion application  

Energy Technology Data Exchange (ETDEWEB)

Negative ion based neutral beam injector is one of the most attractive heating system in future fusion reactors. In realizing the system, the crucial device which has to be developed is a high intensity negative ion source. Significant progress has been made on the negative ion source in these years. Among them, a few ampere negative ion beam were produced stably, while the divergence of negative ion beams becomes to be as low as < 10 mrad. We consider these results are demonstrating the potential of the negative ion source for the heating device in future reactors.

1988-11-01

115

Secondary ions from condensed gas solids by singly and multiply charged ion impacts  

International Nuclear Information System (INIS)

Ion desorption from a condensed gas solid Ne impacted by singly- and multiply-charged Ar"q"+ ions (q = 1-7) has been investigated. Various secondary ions such as cluster ions, Ne"+_n (n = 2-20) as well as atomic ions are observed. Mass spectral patterns, thickness dependence of the yields, and kinetic energy distributions of the desorbed Ne"+_n (n = 1,2) depend strongly on the projectile charge state. These results indicate that the dissipation of the projectile potential energy on the surface leads to the desorption of the monomer and small cluster ions by a Coulomb repulsion between adjacent target ions.

2009-11-01

116

Production of rare-earth atomic negative ion beams in a cesium-sputter-type negative ion source  

International Nuclear Information System (INIS)

The desire to study negative ion structure and negative ion-photon interactions has spurred the development of ion sources for use in research and industry. The many different types of negative ion sources available today differ in their characteristics and abilities to produce anions of various species. Thus the importance of choosing the correct type of negative ion source for a particular research or industrial application is clear. In this study, the results of an investigation on the production of beams composed of negatively-charged rare-earth ions from a cylindrical-cathode-geometry, cesium-sputter-type negative ion source are presented. Beams of atomic anions have been observed for most of the first-row rare-earth elements, with typical currents ranging from hundreds of picoamps to several nanoamps.

2007-08-01

117

Synthetic inorganic ion exchangers. XVI. Electrochromatographic separations of metal ions on zirconium tungstate-impregnated paper  

Energy Technology Data Exchange (ETDEWEB)

The electrochromatographic behavior of 25 metal ions on zirconium tungstate-impregnated papers is described. Six background electrolytes were used. On the basis of the differential mobilities of metal ions which depend on the ion-exchange properties of zirconium tungstate and the nature of complex formation with the electrolytes, some important binary and ternary separations have been achieved.

1980-03-01

118

Production by surface sputtering and acceleration of heavy negative ions in tandem accelerators  

Energy Technology Data Exchange (ETDEWEB)

The main physical processes allowing negative ion production by surface sputtering for further acceleration in tandem acceleration are briefly reviewed. The sputtering yield and the probability of negative ion ejection are discussed. The properties of negative ion beams for an efficient acceleration in tandem accelerators are also discussed, with an emphasis on space charge problems. The main features and performances of the heavy negative ion injector of the Bucharest tandem accelerator are given.

1992-10-05

119

Long pulse extraction of deuterium negative ion beams from the Kamaboko ion source  

Energy Technology Data Exchange (ETDEWEB)

Operation at ITER specifications of the Kamaboko III ion source for 1000 second pulses of deuterium negative ion beams is underway on the MANTIS test stand. Efficient production of negative ions at low arc power requires injection of cesium into the source, temperature control of the plasma grid, and a period of conditioning of several days. Two different concepts of temperature regulated plasma grids are currently being tested. (author)

1998-07-01

120

Coulomb Repulsion in Miniature Ion Mobility Spectrometry  

Energy Technology Data Exchange (ETDEWEB)

We have undertaken a study of ion mobility resolution in a miniature ion mobility spectrometer with a drift channel 1.7 mm in diameter and 35 mm in length. The device attained a maximum resolution of 14 in separating ions of NO, O{sub 2}, and methyl iodine. The ions were generated by pulses from a frequency-quadrupled Nd:YAG laser. Broadening due to Coulomb repulsion was modeled theoretically and shown experimentally to have a major effect on the resolution of the miniature device.

1999-08-08

121

Contribution of the ion-energy distribution to the current-density distribution of a focused-ion beam  

Energy Technology Data Exchange (ETDEWEB)

A general expression for the current-density distribution of a focused-ion beam (FIB) in the chromatic-aberration region is set up in the form of a definite integral. With the experimentally obtained ion-energy distribution of a liquid-metal ion source, its contribution to the FIB current-density distribution is estimated. Calculated results explain the wide-exponential tail of a FIB.

1987-09-01

122

Contribution of the ion-energy distribution to the current-density distribution of a focused-ion beam  

International Nuclear Information System (INIS)

A general expression for the current-density distribution of a focused-ion beam (FIB) in the chromatic-aberration region is set up in the form of a definite integral. With the experimentally obtained ion-energy distribution of a liquid-metal ion source, its contribution to the FIB current-density distribution is estimated. Calculated results explain the wide-exponential tail of a FIB.

123

Analytical determination of the dimensions and evolution with current of the ion-emitting jet in liquid-metal ion sources  

Energy Technology Data Exchange (ETDEWEB)

The apex dimensions and length are calculated as a function of current for the ion-emitting jet in liquid-metal ion sources (LMIS). The results agree well with observations. Since the final expressions are analytical, they give more insight into the fundamental mechanisms involved than do numerical calculations. Some implications of the model are discussed concerning focused ion beam (FIB) systems employing LMIS. (author).

1991-12-14

124

Protons, heavy ions, radioactive beams: new ways for radiotherapy. Protons, ions lourds, faisceaux radioactifs: de nouvelles voies pour la radiotherapie  

Energy Technology Data Exchange (ETDEWEB)

In this article, the author presents the principles, applications and advantages of proton and heavy ion beams used for radiotherapy.

1993-07-01

125

Progress report on negative ion beams based on User Development Workshop on negative ion based neutral beams, 15-16 February, 1983, Princeton  

International Nuclear Information System (INIS)

Progress in the development of negative ion sources and their application in fusion research is reviewed. (U.K.).

1983-04-18

127

Pore region of TRPV3 ion channel is specifically required for heat-activation  

UK PubMed Central (United Kingdom)

Ion-channels can be activated (gated) by a variety of stimuli including chemicals, voltage, mechanical force or temperature. Whereas molecular mechanisms of ion-channel gating by chemicals and...Full Text Available

2008-09-01

128

Mean distance of closest approach of alkaline-earth metals ions in aqueous solutions: Experimental and theoretical calculations  

British Library Electronic Table of Contents (United Kingdom)

The estimation of numerical values of the mean distance of closest approach of ions, a, of alkaline-earth metal ion salts in aqueous solutions, determined from activity coefficients, as well as from different theoretical approaches, is presented and discussed.

2010-01-01

129

Low energy focused ion beams  

Energy Technology Data Exchange (ETDEWEB)

The performance of the PSI/ETH focused ion beam (FIB) system has been improved to produce ion beams of very low energies down to 40 eV with a reasonable spot size of 1 {mu}m at 200 eV. (author) 2 figs., 1 ref.

1996-10-01

130

Ion sources for initial use at the Holifield radioactive ion beam facility  

Energy Technology Data Exchange (ETDEWEB)

The Holifield Radioactive Ion Beam Facility (HRIBF) now under construction at the Oak Ridge National Laboratory will use the 25-MV tandem accelerator for the acceleration of radioactive ion beams to energies appropriate for research in nuclear physics; negative ion beams are, therefore, required for injection into the tandem accelerator. Because charge exchange is an efficient means for converting initially positive ion beams to negative ion beams, both positive and negative ion sources are viable options for use at the facility; the choice of the type of ion source will depend on the overall efficiency for generating the radioactive species of interest. A high-temperature version of the CERN-ISOLDE positive ion source has been selected and a modified version of the source designed and fabricated for initial use at the ...

1994-12-31

131

Ion sources for initial use at the Holifield Radioactive Ion Beam Facility  

Energy Technology Data Exchange (ETDEWEB)

The Holifield Radioactive Ion Beam Facility (HRIBF) now under construction at the Oak Ridge National Laboratory will use the 25-MV tandem accelerator for the acceleration of radioactive ion beams to energies appropriate for research in nuclear physics; negative ion beams are, therefore, required for injection into the tandem accelerator. Because charge exchange is an efficient means for converting initially positive ion beams to negative ion beams, both positive and negative ion sources are viable options for use at the facility; the choice of the type of ion source will depend on the overall efficiency for generating the radioactive species of interest. A high-temperature version of the CERN-ISOLDE positive ion source has been selected and a modified version of the source designed and fabricated for initial use at the ...

1994-05-01

132

Ion clustering in aqueous solutions probed with vibrational energy transfer  

UK PubMed Central (United Kingdom)

Despite prolonged scientific efforts to unravel the hydration structures of ions in water, many open questions remain, in particular concerning the existences and structures of ion clusters in 1∶1...Full Text Available

2011-03-22

133

Cluster-assisted multiple ionization of methyl iodide by a nanosecond laser: Influence of laser intensity on the kinetic energy and peak profile of multicharged ions  

International Nuclear Information System (INIS)

The dependences of kinetic energies and peak profiles of multicharged ions of I "q"+ (q = 2-3) and C"2"+ on the laser intensity have been studied in detail by time-of-flight mass spectrometry, those multicharged ions are produced by irradiation of methyl iodide cluster beam with a nanosecond 532 nm Nd-YAG laser. Our experiments show that the kinetic energies released of multicharged ions increase linearly with the laser intensity in the range of 3 x 10"9-2 x 10"1"1 W/cm"2. The peaks of multicharged ions are split to forward ions and backward ions, and the ratio of the backward ions to forward ions decreases exponentially with laser intensity. The decreasing of backward ions is probably due to Coulomb scattering by the heavier I"+ ions when they turn around through the laser focus ...

2006-03-20

134

Structural and magnetic studies on the enhancement of the giant magnetoimpedance by ion irradiation  

British Library Electronic Table of Contents (United Kingdom)

The mechanism of abrupt increase of the giant magneto impedance (GMI) ratio in the ion irradiated Co-based amorphous ribbon has been investigated. The grazing incident X-ray diffraction and transmission electron microscope were used to characterize the samples before and after ion irradiation. The GMI-ratio considerably increased in the ion irradiated samples and the GMI response showed strong dependence on the driving frequencies. The Barkhausen noise (BN) signals are increased for the Ar ion irradiated sample with dose of 1x10^1^7 ion/cm^2. The results are interpreted in terms of GMI variation associated with domain wall dynamics.

2011-01-01

135

Large ion beams, fundamentals of generation and propagation  

Energy Technology Data Exchange (ETDEWEB)

This book is a compliation and analysis of discussions of phenomena important to ion beams and high perveance ion beams. This text discusses physics essential to research on ion beam generation and propagation and provides some requisite background to understanding the criteria for designing electrodes. Ion sources are categorized in terms of their configurations, and the relationships between various types of sources is developed. Covers collisionless space charge phenomena, collisionless plasmas, collisional effects and the taxonomy of high poissance beams. Chapters also treat the field of intense negative ion beams.

1987-01-01

136

Ion-Specific Hydration Effects: Extending the Poisson-Boltzmann Theory  

CERN Document Server

In aqueous solutions, dissolved ions interact strongly with the surrounding water, thereby modifying the solution properties in an ion-specific manner. These ion-hydration interactions can be accounted for theoretically on a mean-field level by including phenomenological terms in the free energy that correspond to the most dominant ion-specific interactions. Minimizing this free energy leads to modified Poisson-Boltzmann equations with appropriate boundary conditions. Here, we review how this strategy has been used to predict some of the ways ion-specific effects can modify the forces acting within and between charged interfaces immersed in salt solutions.

2011-01-01

137

Ion funnel with extended mass range and reduced conductance limit aperture  

Energy Technology Data Exchange (ETDEWEB)

An improved ion funnel design is disclosed that decreases the axial RF (parasite) fields at the ion funnel exit. This is achieved by addition of one or more compensation electrodes after the conductance limit electrode. Various RF voltage profiles may be applied to the various electrodes minimizing the parasite axial potential wells. The smallest RF aperture that serves as the conductance limiting electrode is further reduced over standard designs. Overall, the ion funnel improves transmission ranges of both low m/z and high m/z ions, reducing RF activation of ions and decreasing the gas load to subsequent differential pumping stages.

2008-04-01

138

Collective ion acceleration by a reflexing electron beam: model and scaling. Memorandum report  

Energy Technology Data Exchange (ETDEWEB)

Analytical and numerical calculations are presented for a reflexing electron beam type of collective ion accelerator. These results are then compared to those obtained through experiment. By constraining one free parameter to experimental conditions, the self-similar solution of the ion energy distribution agrees closely with the experimental distribution. Hence the reflexing beam model appears to be a valid model for explaining the experimental data. Simulation shows in addition to the agreement with the experimental ion distribution that synchronization between accelerated ions and electric field is phase unstable. This instability seems to further restrict the maximum ion energy to several times the electron energy.

1984-05-11

139

A new scheme of the longitudinal emittance measurement for negative ion beams  

Energy Technology Data Exchange (ETDEWEB)

A new scheme of the longitudinal emittance measurement for high energy negative ion beam is proposed. The energy distribution of the detached electron from the negative ions by the photodetachment process, if the photon energy is almost equal to the electron binding energy of the negative ion (=electron affinity of the atom), reflects that of the original negative ions. Therefore, by introducing the photon in a short width comparing with the bunch width of the negative ion beam, the longitudinal energy distribution of each phase of the beam, that is the longitudinal emittance, can be measured. (author).

1995-08-01

141

Studies of relativistic heavy ion collisions at the AGS (Experiment 814)  

Energy Technology Data Exchange (ETDEWEB)

This report discusses the experimental setup of experiment 814 at Brookhaven AGS. This experiment involves the collision of silicon ions with target nuclei. The detector systems are discussed primarily. (LSP)

1990-01-01

142

Selective radiochemical separation for indium determination at ppb levels in ion-implanted semiconductor-grade silicon  

Energy Technology Data Exchange (ETDEWEB)

A specific radiochemical procedure for indium determination in semiconductor-grade silicon, using an inorganic ion exchanger (cerium oxalate) is proposed.

1982-12-23

143

New and old Sn isomers produced in heavy-ion collisions  

International Nuclear Information System (INIS)

The energy level schemes of tin isotopes produced in the heavy ion reactions are presented. The using of #gamma# spectroscopy technique is also described. 4 refs, 12 figs.

1991-12-01

144

Kinetic energy dependence of the reactions of N"+ ions with NO, CO, CO_2, N_2O and SO_2  

International Nuclear Information System (INIS)

... kinetics chemical reactions energy dependence ion-molecule collisions milli

1977-07-01

145

Ion nitriding; Proceedings of the International Conference, Cleveland, OH, Sept. 15-17, 1986  

Energy Technology Data Exchange (ETDEWEB)

The present conference discusses plasma-assisted surface coating/modification processes, the applications to date of ion nitriding, the effects of nitrogen on metal surfaces, ion nitriding mechanisms in Cr, Al and Cr + Al-containing 1040 steel, ion nitriding of Al and its alloys, life enhancement for forging dies, novel anode plasma nitriding developments, and a comparative study of the pulsed and dc ion-nitriding behavior in specimens with blind holes. Also discussed are the influence of heating method on ion nitriding, surface hardening of marage steels by ion nitriding without core hardness reduction, plasma nitriding of nodular cast iron sput gears, NbN composites for superconductors, the carburization of tungsten in a glow discharge methane plasma, economic considerations concerning plasma nitriding, and the corrosion properties obtained by ...

1987-01-01

146

Induction and Repression of Nitrate Reductase in Neurospora crassa  

UK PubMed Central (United Kingdom)

Synthesis of wild-type Neurospora crassa assimilatory nitrate reductase is induced in the presence of nitrate ions and repressed in the presence of ammonium ions. Effects of several...Full Text Available

1978-02-01

147

First ion beam transfered from the SPS to the LHC  

CERN Multimedia

An ion beam has been successfully transfered from the SPS to the LHC for the first time on 12 November 2007.

2007-01-01

148

Accelerator-based analytical techniques using ion and photon beams. Environmental and industrial applications  

International Nuclear Information System (INIS)

An overview of different Ion Beam Analysis (IBA) techniques is given. Examples of applications of the PIXE techniques to various types of samples are presented. (author)

1999-11-01

149

Self-lubricating performance and durability of ball bearings for the LE-7 liquid oxygen rocket-turbopump  

Energy Technology Data Exchange (ETDEWEB)

The durability of ball bearings, 32-mm- and 45-mm-bore, with a retainer or glass cloth-polytetrafluoroethylene (PTFE) laminate was tested under a high radial load at a speed of 20,000 rpm in LOX or LN2. The retainers were characterized as good self-lubricators because the abrasive glass-cloth fiber tips exposed on the retainer were chemicaly etched away with hydrofluoric acid (HF). During testing, the bearing-cartridge-acceleration was monitored to detect bearing damage. Testing in LOX for about 2.2 hr showed that excellent lubricating conditions were obtained for all bearings. Testing in LN2 for about 5.1 hr detected that the fatigue life of the bearing was about the same as the calculated B10 fatigue life. The HF chemical treatment resulted in a reacted fluoride-oxide material which remained in the etched part of the glass fiber. Several chemical products, particularly MgO, CaO, and CaCO3, enhanced adhesion of PTFE transfer film to the counterface, resulting in ...

1993-09-01

150

Quantitative monitoring of the fluorination process by neutron counting  

Energy Technology Data Exchange (ETDEWEB)

Plutonium metal is produced by reducing PuF{sub 4} prepared from PuO{sub 2} by fluorination. Both fluorination and reduction are batch processes at the Los Alamos Plutonium Facility. The conversion of plutonium oxide to fluoride greatly increases the neutron yield, a result of the high cross section for alpha-neutron ({alpha},n) reactions on fluorine targets compared to the (more than 100 times) smaller {alpha},n yield on oxygen targets. Because of the increase, total neutron counting can be used to monitor the conversion process. This monitoring ability can lead to an improved metal product, reduced scrap for recycle, waste reduction, minimized reagent usage, and reduce personnel radiation exposures. A new stirred-bed fluorination process has been developed simultaneously with a recent evaluation of an automated neutron-counting instrument for quantitative process monitoring. Neutrons are counted with polyethylene-moderated {sup 3}He-gas proportional counters. ...

1993-12-31

151

Modeling of Fission Neutrons as a Signature for Detection of Highly Enriched Uranium  

Energy Technology Data Exchange (ETDEWEB)

We present the results of modeling intended to evaluate the feasibility of using neutrons from induced fission in highly enriched uranium (HEU) as a means of detecting clandestine HEU, even when it is embedded in absorbing surroundings, such as commercial cargo. We characterized radiation from induced fission in HEU, which consisted of delayed neutrons at all energies and prompt neutrons at energies above a threshold. We found that for the candidate detector and for the conditions we considered, a distinctive HEU signature should be detectable, given sufficient detector size, and should be robust over a range of cargo content. In the modeled scenario, an intense neutron source was used to induce fissions in a spherical shell of HEU. To absorb, scatter, and moderate the neutrons, we place one layer of simulated cargo between the source and target and an identical layer between the target and detector. The resulting neutrons and gamma rays are resolved in both time and energy to reveal ...

2004-03-09

152

Low-temperature phase transitions and magnetic susceptibilities of low-dimensional uranium fluorides  

International Nuclear Information System (INIS)

Measurements have been made on the magnetic susceptibilities of the quasi-one-dimensional magnetic #approx#-UF_5 and the cluster magnetic U_2F_9 (a four-nuclear type) over the range 4.2-300 K. The Curie-Weiss law applies for #approx#-UF_5 above 200 K, with #mu#ef = 2.37#mu#B, theta = -148 K; that law also applies to U_2F_9 above 150 K, with #mu#ef = 2.9#mu#B and theta = 118 K. The antiferromagnetic ordering is discussed for the one-dimensional chains in #approx#-UF_5 together with the phase transition observed in U_2F_9 at 6 K. It is assumed that the U"4"+ and U"5"+ valency states are stabilized below the phase-transition point, and only then can U_2F_9 be considered as the compound UF_4 x UF_5.

1987-01-01

153

Equation of state of laser-shocked compressed iron; Equation d'etat du fer comprime par choc laser  

Energy Technology Data Exchange (ETDEWEB)

This thesis enters the field of highly compressed materials equation of state studies. In particular, it focuses on the case of laser shock compressed iron. This work indeed aims at getting to the conditions of the earth's core, comprising a solid inner core and a liquid outer core. The understanding of phenomena governing the core's thermodynamics and the geodynamic process requires the knowledge of iron melting line locus around the solid-liquid interface at 3.3 Mbar. Several experiments were performed to that extent. First, an absolute measurement of iron Hugoniot was obtained. Following is a study of partially released states of iron into a window material: lithium fluoride (LiF). This configuration enables direct access to compressed iron optical properties such as reflectivity and self-emission. Interface velocity measurement is dominated by compressed LiF optical properties and is used as a pressure gauge. Using a dual wavelength ...

2004-01-01

154

Electrometallurgical treatment of aluminum-matrix fuels  

Energy Technology Data Exchange (ETDEWEB)

The electrometallurgical treatment process described in this paper builds on our experience in treating spent fuel from the Experimental Breeder Reactor (EBR-II). The work is also to some degree, a spin-off from applying electrometallurgical treatment to spent fuel from the Hanford single pass reactors (SPRs) and fuel and flush salt from the Molten Salt Reactor Experiment (MSRE) in treating EBR-II fuel, we recover the actinides from a uranium-zirconium fuel by electrorefining the uranium out of the chopped fuel. With SPR fuel, uranium is electrorefined out of the aluminum cladding. Both of these processes are conducted in a LiCl-KCl molten-salt electrolyte. In the case of the MSRE, which used a fluoride salt-based fuel, uranium in this salt is recovered through a series of electrochemical reductions. Recovering high-purity uranium from an aluminum-matrix fuel is more challenging than treating SPR or EBR-II fuel because the aluminum- matrix fuel is typically -90% ...

1996-08-01

155

Design of the heat receiver for the U.S./Russia solar dynamic power joint flight demonstration  

Energy Technology Data Exchange (ETDEWEB)

A joint US/Russia program is being conducted to develop, fabricate, launch, and operate a solar dynamic demonstration system on Space Station Mir. The goal of the program is to demonstrate and confirm that solar dynamic power systems are viable for future space applications such as the International Space Station Alpha. The major components of the system include a heat receiver, a closed Brayton cycle power conversion unit, a power conditioning and control unit, a concentrator, a radiator, a thermal control system, and a Space Shuttle carrier. This paper discusses the design of the heat receiver component. The receiver comprises a cylindrical cavity, the walls of which are lined with a series of tubes running the length of the cavity. The engine working fluid, a mixture of xenon and helium, is heated by the concentrated sunlight incident on these tubes. The receiver incorporates integral thermal storage, using a eutectic mixture of lithium fluoride and calcium ...

1995-12-31

156

Coated semiconductor devices for neutron detection  

Energy Technology Data Exchange (ETDEWEB)

A device for detecting neutrons includes a semi-insulated bulk semiconductor substrate having opposed polished surfaces. A blocking Schottky contact comprised of a series of metals such as Ti, Pt, Au, Ge, Pd, and Ni is formed on a first polished surface of the semiconductor substrate, while a low resistivity ("ohmic") contact comprised of metals such as Au, Ge, and Ni is formed on a second, opposed polished surface of the substrate. In one embodiment, n-type low resistivity pinout contacts comprised of an Au/Ge based eutectic alloy or multi-layered Pd/Ge/Ti/Au are also formed on the opposed polished surfaces and in contact with the Schottky and ohmic contacts. Disposed on the Schottky contact is a neutron reactive film, or coating, for detecting neutrons. The coating is comprised of a hydrogen rich polymer, such as a polyolefin or paraffin; lithium or lithium fluoride; or a heavy metal fissionable material. By varying the coating thickness and electrical settings, ...

2002-01-01

157

Long pulse production of high current D"- ion beams in the JT-60 negative ion source  

International Nuclear Information System (INIS)

The first long pulse production of high power D"- ion beams has been demonstrated in the JT-60 U negative ion sources, each of which was designed to produce 22 A, 500 keV D"- ion beams. Voltage holding capability and the grid power loading were examined for long pulse production of high power D"- ion beams. From the correlation between voltage holding and the light intensity of cathodoluminescence from the Fiber Reinforced Plastic insulators, the acceleration voltage for stable voltage holding capability was found to be less than 320-340 kV where the light was sufficiently suppressed. By tuning the extraction voltage, the grid power loadings in the ion sources were decreased to the allowable levels for long pulse injection without a significant reduction of the beam power. After tuning the acceleration and extraction voltages, D"- ion beams of 12.5 and 9.8 A ...

2008-02-01

158

rf-driven ion sources for industrial applications (invited) (abstract)  

Science.gov (United States)

The Plasma and Ion Source Technology Group at the Lawrence Berkeley National Laboratory have been developing rf-driven ion sources for the last two decades. These sources are being used to generate both positive and negative ion beams. Some of these sources are operating in particle accelerators such as the Spallation Neutron Source (SNS) at Oak Ridge, while others are being employed in various industrial ion beam systems. There are four areas where the rf-driven ion sources are commonly used in industry. (1) In semiconductor manufacturing, rf-driven sources have found important applications in plasma etching, ion beam implantation, and ion beam lithography. (2) In material analysis and surface modification, miniature rf-ion sources can be found in focused ion beam systems. They can provide ...

2008-02-15

159

The physics of production, acceleration and neutralization of large negative ion beams  

Energy Technology Data Exchange (ETDEWEB)

Neutral beam systems for the next generation of magnetic fusion devices will be based on negative ions. Development are progressing steadily, and large negative ion-based systems are prepared for JT60-U and LHD, and are being considered for ITER. An overview of the physics of the production, acceleration and neutralization of large negative ion beams is given. the present state of the art in Research and Development is also surveyed. (author). 55 refs., 10 figs., 1 tab.

1995-12-31

160

The physics of production, acceleration and neutralization of large negative ion beams  

Energy Technology Data Exchange (ETDEWEB)

Neutral beam systems for the next generation of magnetic fusion devices will be based on negative ions. Developments are progressing steadily, and large negative ion-based systems are under preparation for JT60-U and LHD, and are being considered for ITER. An overview of the physics of the production, acceleration and neutralization of large negative ion beams is given. The present state of the art in R and D is also surveyed. (Author).

1995-11-01

162

Summary and closing remarks  

Energy Technology Data Exchange (ETDEWEB)

A summary of the topics covered in papers presented at the 1995 Brookhaven joint conference on production, neutralization, and application of negative ion beams is given. The conference topics covered included plasma ion sources, plasma seeding of these sources for increased ion production, beam extraction and transport, computer simulation and design studies, and operation of existing and experimental ion source facilities. Application of the sources to accelerator, tokamak, and thin film deposition are discussed. (AIP) {copyright} {ital 1996 American Institute of Physics.}

1996-07-01

164

Selection and design of ion sources for use at the Holifield radioactive ion beam facility  

Energy Technology Data Exchange (ETDEWEB)

The Holifield Radioactive Ion Beam Facility now under construction at the Oak Ridge National Laboratory will use the 25 MV tandem accelerator for the acceleration of radioactive ion beams to energies appropriate for research in nuclear physics; negative ion beams are, therefore, required for injection into the tandem accelerator. Because charge exchange is an efficient means for converting initially positive ion beams to negative ion beams, both positive and negative ion sources are viable options for use at the facility. The choice of the type of ion source will depend on the overall efficiency for generating the radioactive species of interest. Although direct-extraction negative ion sources are clearly desirable, the ion formation efficiencies are often too low for practical consideration; for ...

1994-06-01

166

Oxygen Implanted Materials  

International Science & Technology Center (ISTC)

Development of Oxygen Ion-Implanted Collector materials for Thermal Emission Converters of Thermal Energy into the Electric One.

167

On the Metastable Level in Ni-like Ions  

Energy Technology Data Exchange (ETDEWEB)

The lowest excited level in Ni-like ions, 3d{sup 9}4s {sup 3}D{sub 3}, decays only via a magnetic octupole (M3) decay. They present calculated values of transition wavelengths and rates for ions with 30 {le} Z {le} 100. They have observed this line in Xe{sup 26+}, using the Livermore EBIT-I electron beam ion trap and a microcalorimeter, as well as a high-resolution flat-field grating spectrometer.

2004-09-14

168

Negative ion formation in magnetically insulated transmission lines  

Energy Technology Data Exchange (ETDEWEB)

Negative ion intensities of over 3 x 10/sup 5/ A/m/sup 2/ at energies of 2 MeV have been measured in a magnetically insulated transmission line. This negative ion production can affect the power flow in multiterawatt pulsed power devices, and may also have applications in the generation of high-intensity neutral or negative ion beams.

1982-05-01

169

Micromachining using focused ion beams  

Energy Technology Data Exchange (ETDEWEB)

Focused ion beam (FIB) systems prove to be useful precision micromachining tools for a wide variety of applications. This micromachining technique includes scanning ion microscopy (SIM), micromachining by physical sputtering, and the ion-beam induced surface chemistry for etching and deposition. This technique is applied to image and modify IC's, to micromechanical applications, to modify the tip shape of tungsten emitters, and to prepare cross sections of selected regions for inspection in a transmission electron microscope (TEM). (orig.)

1994-11-16

170

Ion-Track Membranes and Their Use in Biological and Medical Applications  

International Nuclear Information System (INIS)

This report is a brief review of biological and medical applications of ion-track membranes. The review aims at informing nuclear physicists about alternative (i.e. non-fundamental-science) use of heavy ion accelerators such as production of micro- and nano-porous materials. The ion-track membranes produced this way are employed in life sciences and numerous technological applications. The author focuses on recent results from the Flerov laboratory in co-operation with other scientific institutions and industrial partners.

2007-05-22

176

Highly efficient ion source for analysis of transuranium elements  

Energy Technology Data Exchange (ETDEWEB)

Results are described of the study of the analytical applicability of a highly efficient ion source developed for a mass spectrometer. Its ionizer is in the form of a partially closed cavity with a small aperture for leading out ions, heated to a high temperature. The new ion source increases the sensitivity of the apparatus in operations with transuranium elements by almost two orders of magnitude. It is possible to perform isotopic analyses with a high salt content in the sample, and to study the characteristics of nuclear fuel, even without chemical separation of the sample elements.

1987-01-01

181

Development of heavy-ion irradiation technique for single-event in semiconductor devices  

Energy Technology Data Exchange (ETDEWEB)

Heavy-ion irradiation technique has been developed for the evaluation of single-event effects on semiconductor devices. For the uniform irradiation of high energy heavy ions to device samples, we have designed and installed a magnetic beam-scanning system in a JAERI cyclotron beam course. It was found that scanned area was approximately 4 x 2 centimeters and that the deviation of ion fluence from the average value was less than 7%. (author)

1997-03-01

182

Density changes in amorphous Pd{sub 80}Si{sub 20} during low temperature ion irradiation  

Energy Technology Data Exchange (ETDEWEB)

Density changes in amorphous Pd{sub 80}Si{sub 20} during ion irradiation below 100K were detected by in situ HVEM measurements of the changes in specimen length as a function of ion fluence. A decrease in mass density as a function of the ion fluence was observed. The saturation value of the change in mass density was determined to be approximately -1.2%.

1994-11-01

183

Calculation of the imaginary part of the heavy ion potential  

Energy Technology Data Exchange (ETDEWEB)

The paper contains a numerical evaluation of the expressions for the absorptive potential in heavy ion reactions given earlier. With a standard folding expression for the real part of the ion-ion potential general good agreement is found with experimental data for the angular distributions of elastic and inelastic scattering. Special interest is attached to the case of /sup 16/O + /sup 28/Si where the calculated imaginary potential is very small at low bombarding energies.

1983-09-19

184

Calculation of the imaginary part of the heavy ion potential  

International Nuclear Information System (INIS)

The paper contains a numerical evaluation of the expressions for the absorptive potential in heavy ion reactions given earlier. With a standard folding expression for the real part of the ion-ion potential general good agreement is found with experimental data for the angular distributions of elastic and inelastic scattering. Special interest is attached to the case of "1"6O + "2"8Si where the calculated imaginary potential is very small at low bombarding energies. (orig.).

186

{delta}f simulation of ion neoclassical transport  

Energy Technology Data Exchange (ETDEWEB)

Ion neoclassical transport with finite orbit width dynamics is calculated over whole poloidal cross section by using accurate {delta}f method which employs an improved like-particle collision operator and an accurate weighting scheme to solve drift kinetic equation. Ion thermal transport near magnetic axis shows a great reduction from its conventional neoclassical level due to non-standard orbit topology, like that of previous {delta}f simulation. On other hand, the direct particle loss from confinement region may strongly increase ion energy transport near the edge. It is found that ion parallel flow near the axis is also largely reduced due to non-standard orbit topology. In the presence of steep density gradient, ion thermal conductivity is significantly reduced, and an ion particle flux is driven by self-collision alone. (author)

1999-07-01

187

The effects of counter cation on lithium ion conductivity: In the case of the perovskite-type titanium oxides of La2/3?x Li3xTiO3 and LaTiO3  

British Library Electronic Table of Contents (United Kingdom)

We performed hybrid-DFT calculations for La2/3?xLi3xTiO3 (LLT) with lithium ion conductivity, in order to investigate the detailed lithium ion conductive mechanism from the viewpoint of molecular orbital (MO) method. It was concluded that the very ionic lithium ion in bottleneck accelerates the lithium ion conduction. The calculated MO shows no chemical bonding between lithium ion and other ions. In comparison with the perovskite-type trivalent titanium oxide of LaTiO3, the effect of the titanium's reduction was also investigated. We showed the possibility of the high lithium conductivity in LaTiO3.

2009-01-01

188

The development of high-intensity negative ion sources and beams in the USSR. Technical report  

Energy Technology Data Exchange (ETDEWEB)

This report reviews Soviet R and D of (1) high-intensity negative ion sources and (2) transport and focusing of negative ion beams, using Soviet open literature of the past ten years, and correlates this data with data on Soviet institutes responsible for negative ion beam development. The Soviets are developing intense negative ion beams as the basis for creating neutral beams for injection into mirror traps and tokamaks, for inertial confinement fusion, and possibly for exoatmospheric beam weapon applications. The report focuses specifically on surface-plasma-type ion sources, which were first developed in the USSR and which show great promise for creating beams of high intensity, high brightness, and low emittance. Mechanisms for optimum negative ion beam transport are also discussed.

1981-09-01

189

Technique for the removal of electrons from an extracted, pulsed, H{sup {minus}} ion beam  

Energy Technology Data Exchange (ETDEWEB)

A small, permanent-magnet insert structure for the removal of electrons from pulsed, extracted, negative ion beams has been developed at Lawrence Berkeley National Laboratory. The device was computer modeled and designed for an extraction field strength of 3 kV/mm. The testing was carried out with a rf driven multicusp ion source optimized for the production of H{sup {minus}} ions and pulsed at a few Hz with pulse widths of several hundreds of {mu}s. It is demonstrated that the insert structure together with a collar can remove over 98{percent} of electrons from the extracted H{sup {minus}} ion beam without any significant deterioration of the H{sup {minus}} ion output. Application to other negative ion beams can be expected from this magnetic collar insert. {copyright} {ital 1996 American Institute of Physics.}

1996-10-01

190

Propagation of Surface Ripples on Pyrochlore Single Crystals Induced by Ion Beam Bombardment  

Energy Technology Data Exchange (ETDEWEB)

The morphological evolution of ripples formed on the surface of Cd2Nb2O7 pyrochlore single crystals by focused ion beam (FIB) bombardment was investigated using in situ electron microscopy. At high ion fluences and off-normal bombardment angles, faceted surface ripples with a terrace-like structure were observed. The ripple propagation direction was oriented along the projected ion beam direction at incident angles ranging from 35 to 65 following high-dose ion bombardment. One side of the terrace was found to be perpendicular to the incident ion beam direction, while the other side was parallel to the ion beam. The terrace propagation velocity and direction were determined and interpreted on the basis of this asymmetric structure. A model based on the propagation of a shock wave that effectively self-selects a stable slope, was developed in order to explain the ...

2009-08-01

191

PIC Simulations Of Ion Acceleration By Linearly And Circularly Polarized Laser Pulses  

Science.gov (United States)

Linearly polarized laser radiation accelerates electrons to very high velocities and these electron form a sheath layer on the rear side of thin targets where preferentially protons are accelerated. When mass-limited targets are used, the lateral transport of the absorbed laser energy is reduced and the accelerating field is enhanced. For targets consisting of two ion species, heavier ions facilitate formation of quasi-monoenergetic bunch of lighter ions. For circularly polarized light, fast electron production is suppressed by the absence of the oscillatory component of the ponderomotive force. Ions are accelerated on the front side by the separation field and very thin foil can be accelerated as one massive quasi-neutral block. As all ion species acquire the same velocity, this acceleration mechanism is preferred for heavier ions.

2008-06-24

192

Focused ion beam (FIB) milling of electrically insulating specimens using simultaneous primary electron and ion beam irradiation  

International Nuclear Information System (INIS)

There is currently great interest in combining focused ion beam (FIB) and scanning electron microscopy technologies for advanced studies of polymeric materials and biological microstructures, as well as for sophisticated nanoscale fabrication and prototyping. Irradiation of electrically insulating materials with a positive ion beam in high vacuum can lead to the accumulation of charge, causing deflection of the ion beam. The resultant image drift has significant consequences upon the accuracy and quality of FIB milling, imaging and chemical vapour deposition. A method is described for suppressing ion beam drift using a defocused, low-energy primary electron beam, leading to the derivation of a mathematical expression to correlate the ion and electron beam energies and currents with other parameters required for electrically stabilizing these challenging materials.

2007-02-07

193

Development of liquid metal ion sources, focused ion beam and their applications  

International Nuclear Information System (INIS)

To suit the needs of development for manufacture VLSI, we started to investigate liquid metal ion sources (LMIS) and focused ion beam (FIB) in 1984. Many kinds of emitters viz. neddle type, co-axial type and capillary type of Ga and Au LMIS and three kinds of eutectic alloys LMIS (Au-Si, Au-Si-Be, Pd-Ni-Si-Be-B) have been tested. A program which can calculate focused ion guns has been written. Four kinds of foused ion guns have been operated, a fine beam with diametic 0.1 #mu#m is obtained. Using the FIB a scanning ion microscope has been constructed. Some tests of etching and self-developing of nitrocellulose are described. (author).

194

Analysis by mass spectroscope device provided with ion source of induced plasma  

International Nuclear Information System (INIS)

This chapter consists of some points including an introduction, the basic parts of mass spectroscope device, sample introduction into the inductively coupled plasma, pneumatic nebuliser, ultrasonic nebuliser, dry gas cloud system, laser ablation unit, inductively coupled plasma-ion source, extraction of ions from ion source, mass analysis, quad-polar mass spectrometer, dual assembly mass spectrometer, mass spectrometer by calculation of time of flight, ion interferences and the ability of resolution, ion counter, working conditions of inductively coupled plasma mass spectroscope device, efficiency of ion transportation in an inductively coupled plasma mass spectroscope device and applications of analysis using mass spectroscope of induced plasma including nuclear, industrial, geological, environmental and archaeological applications, measurement of isotopes ...

195

A novel approach for measuring the radial distribution of charge in a heavy ion track  

International Nuclear Information System (INIS)

The energy deposited by the passage of a single, energetic, heavy-ion through a semiconductor produces dense electron-hole (eh) pair concentrations near the ion trajectory. The size, shape, and charge density of an ion track represent critical parameters for many models of single event phenomena. The authors describe the design and uses of possible semiconductor test structures for measuring the initial radial distribution of charge and subsequent charge transport in a high energy, heavy-ion track. Numerical simulations show how the test structure can resolve different radial distributions of charge within an ion track. The test structure simulations also show the importance of accurately representing ion track structure in single event effects simulations.

1994-07-18

196

Negative ion source electrode  

Energy Technology Data Exchange (ETDEWEB)

The present invention concerns a negative ion source electrode which can be preferably used in a neutral particle injection device using negative ions for a thermonuclear reactor. Negative ion beams are deflected to the direction opposite to the deflecting direction by magnetic fields by using an electron suppression electrode having electrode holes with the position previously displaced before negative ion beams are accelerated to have a high energy by an accelerator thereby correcting the orbit of the negative ion beams easily. In addition, since the deflection correction electrode having the electrode holes is disposed, a proper voltage is applied to the deflection correction electrode to correct the orbit of the negative ion beams conveniently. Since the deflection correction electrode has a simple structure of a thin flat plate having electrode holes, the ...

1997-01-17

197

Long-life bismuth liquid metal ion source for focussed ion beam micromachining application  

International Nuclear Information System (INIS)

Liquid metal ion sources (LMISs) with Ga as ion species are widely used in focused ion beam (FIB) technology for micromachining and surface treatment on the sub-micron and nano-scale. Key features of a LMIS for investigating mechanical properties and 3D-microfabrication of materials are long life-time, high brightness, stable ion current and a highly effective milling ability for the material to be modified. In order to increase the material removal rate, heavier ions than Ga and their clusters should be applied. Bismuth (Bi) is the heaviest, non-radio-active element in the periodic table, is non-toxic and exhibits a low melting point. We have thus produced a long-life (about 1000 h) Bi LMIS with a good beam performance, applicable in any FIB system. Since Bi is the only element in this source, it is not necessary to separate it from other ions by a mass filter. ...

2008-09-15

198

Using focused ion beam damage patterns to photoelectrochemically etch features in III-V materials  

Energy Technology Data Exchange (ETDEWEB)

A method of patterning n-type GaAs, InP, InGaAs, and InGaAsP by photoelectrochemical (PEC) etching in conjunction with a submicron focused ion beam (FIB) at low dose is described. The ion beam is used to produce damage in a desired pattern in the material. Subsequent PEC etching of the material reveals the ion induced features in relief. The procedure is highly sensitive, requiring a dose of only 5 x 10/sup 9/ ions/cm/sup 2/ for the differential etch to become apparent. The sensitivity allows rapid pattern generation in our FIB system.

1986-03-10

199

Uses of laser optical pumping to produce polarized ion beams  

Energy Technology Data Exchange (ETDEWEB)

Laser optical pumping can be used to produce polarized alkali atom beams or polarized alkali vapor targets. Polarized alkali atom beams can be converted into polarized alkali ion beams, and polarized alkali vapor targets can be used to produce polarized H/sup -/ or /sup 3/He/sup -/ ion beams. In this paper the authors discuss how the polarized alkali atom beams and polarized alkali vapor targets are used to produce polarized ion beams with emphasis on the production of polarized negative ion beams.

1983-04-01

200

Treatment technology for transuranic waste streams: Cementation, vitrification, and incineration testing for the treatment of spent ion exchange media  

Energy Technology Data Exchange (ETDEWEB)

This document reports the results of testing of spent ion exchange media pretreatment technologies. Emphasis of the testing activities has been on screening pretreatment technologies, such as drying and emulsification, which are compatible with vitrification, cementation, and incineration. Ion exchange media tested for cementation and incineration pretreatment technologies were typical organic ion exchange resins and inorganic zeolites. The ion exchange medium tested for vitrification pretreatment technologies was inorganic zeolite. The results of testing activities are discussed in detail in this report.

1992-04-01

201

Species dependence of the emittances of sputter-generated negative ion beams  

Energy Technology Data Exchange (ETDEWEB)

We report experimental evidence of a previously unseen species-dependent effect in the transverse emittances of momentum analysed /sup 28/Si/sup -/, /sup 58/Ni/sup -/ and /sup 197/Au/sup -/ ion beams generated by caesium ion sputtering. The high-resolution emittance measurement techniques employed in this work have enabled us to estimate the energy spreads of these ion beams; differences in the widths of the energy distributions are the origin of the observed differences in emittances of the ion beams investigated. (author).

1989-04-14

202

Spatial and angular characteristics of microsecond negative-ion beams in a magnetically insulated diode  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the design of a high-voltage negative ion source based on a magnetically insulated diode and generating microsecond pulses. Plane an cylindrical cathodes have been tested. The spatial and angular distributions of negative ions in the beam have been measured. The content of negative ions with different masses in the beam are given. The ion current density measured by a Faraday cup was up to 1 A/cm{sup 2} for the radial beam and 30-40 A/cm{sup 2}.

1995-10-01

203

Solenoid transport for heavy ion fusion  

Energy Technology Data Exchange (ETDEWEB)

Solenoid transport of high current, heavy ion beams is considered for several stages of a heavy ion fusion driver. In general this option is more efficient than magnetic quadrupole transport at sufficiently low kinetic energy and/or large e/m, and for this reason it has been employed in electron induction linacs. Ideally an ion beam would be transported in a state of Brillouin flow, i.e. cold in the transverse plane and spinning at one half the cyclotron frequency. The design of appropriate solenoids and the equilibrium and stability of transported ion beams are discussed. An outline of application to a fusion driver is also presented.

2004-06-15

204

Production of a helium beam in a focused ion beam machine using an electron beam ion trap  

International Nuclear Information System (INIS)

Gallium liquid-metal ion sources that have been introduced in the late 1970s have allowed the development of a new class of micro- and nanofabrication tools collectively denominated as focused ion beam (FIB) machines. To investigate the potential of a helium beam in such a FIB instrument the authors have tested a room-temperature electron beam ion trap coupled with a high resolution FIB machine. In this letter they present their first results in target imaging using a helium beam with a resolution that allows to account for a beam diameter in the submicrometer range.

2007-02-19

205

Production of Group IIA atomic and molecular negative ion beams in a cesium-sputter negative ion source  

Energy Technology Data Exchange (ETDEWEB)

The results of an investigation on the production of Group IIA atomic and molecular negative ion beams formed in a cesium-sputter negative ion source are presented. The sputtering material was formed by pressing pellets of stoichiometric mixtures of the Group IIA element carbonates and 10% copper powder. Negative ions of several alkaline-earth elements and their oxides have been observed. Beam intensities as high as 180 pA have been observed for Sr{sup -}and 20 nA for SrO{sup -}. (orig.).

1996-09-11

206

Production of Group IIA atomic and molecular negative ion beams in a cesium-sputter negative ion source  

International Nuclear Information System (INIS)

The results of an investigation on the production of Group IIA atomic and molecular negative ion beams formed in a cesium-sputter negative ion source are presented. The sputtering material was formed by pressing pellets of stoichiometric mixtures of the Group IIA element carbonates and 10% copper powder. Negative ions of several alkaline-earth elements and their oxides have been observed. Beam intensities as high as 180 pA have been observed for Sr"-and 20 nA for SrO"-. (orig.).

1996-09-01

207

Plasma immersion ion implantation. (Latest citations from the EI Compendex*plus database). Published Search  

Energy Technology Data Exchange (ETDEWEB)

The bibliography contains citations concerning plasma immersion ion implantation (PIII) and equipment. PIII is a new technique to implant plasma ions into materials for surface modification and treatment. Topics include plasma nitriding, semiconductor doping, ion energy distribution, ion dose, pulsed plasma, metal plasma, and defect passivation. References also review applications in semiconductor device and integrated circuit manufacture, silicon material fabrication, aerospace bearings, carbon coatings on metals, and ceramic coatings. (Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

1998-01-01

208

Phonon-mediated entanglement for trapped ion quantum computing  

Energy Technology Data Exchange (ETDEWEB)

Trapped ions are a near ideal system to study quantum information processing due to the high degree of control over the ion's external confinement and internal degrees of freedom. We demonstrate the key steps necessary for trapped ion quantum computing and focus on phonon-mediated entangling gates. We highlight several key algorithms implemented over the last decade with these gates and give a detailed description of Grover's quantum database search implemented with two trapped ion qubits.

2010-03-15

209

New coumarin-based sensor molecule for magnesium and calcium ions  

British Library Electronic Table of Contents (United Kingdom)

A new coumarin-based sensor molecule (L1) has been synthesized and this was found to bind calcium and magnesium ions more effectively as compared to other alkali/alkaline earth/lanthanide and certain transition metal ions. A significant enhancement in fluorescence intensity was observed on binding to Ca2+ and Mg2+ ions; while a minor quenching was observed for weakly bound Hg2+, Ni2+, Fe3+, and Co2+ ions. PET process, coupled with the ICT process, is proposed to explain the observed spectral response.

2009-01-01

210

Measurements for microamounts of SO_4"2"-, Br"-, I"- ions in the carnallite  

International Nuclear Information System (INIS)

The variations of measurements were estimated for microamounts SO_4"2"-, Br"-, I"- ions in samples of carnallite by ionchromatography method. The composition of carbonate eluent was verified. The investigated minima were about 0,004 %, 0,001 %, 0,01 % for SO_4"2"-, Br"-, I"- completively correspondingly. It was shown that the limit of ion-chromatography measurement would be decreased when Br"- and I"- ions were concentrated by extraction before. Besides the determination of I"- ion in carnallite was preformed by potentiometry with I"--ionselective electrode. 6 refs.; 3 tabs.

1995-01-01

211

Irradiation by carbon ions?: why? How?; Irradiation par ions carbone: pourquoi? Comment?  

Energy Technology Data Exchange (ETDEWEB)

The interest of irradiation by carbon ions is in the fact that the carbon ions leave all their energy to a determined depth. ( phenomenon known under the name of Bragg peak)This high diffusion in tissue gives an RBE particularly high. The indications of this therapy are chordomas, and chondrosarcomas of the skull base, some cyst adenoid carcinomas, pulmonary cancer, sarcomas, hepato carcinomas, melanomas. In the light of results in term of efficiency, the place of irradiation by carbon ions should widen. (N.C.)

2006-11-15

212

Emittance characteristics of negative ion beams generated by the sputter technique  

Energy Technology Data Exchange (ETDEWEB)

Average emittance data for ion beams extracted from cesium-sputter negative ion sources equipped with spherical, ellipsoidal, and cylindrical geometry cesium-surface ionizers are presented. The attributes of the respective source geometries are described in terms of their cesium ion optical properties. The results of recent measurement of the emittances of momentum-analyzed beams extracted from the ellipsoidal geometry source are also presented. These measurements indicate the presence of a species-dependent effect. The effect is believed to be attributable to differences in the energy spreads of the respective negative ion beams introduced by the sputter generation process.

1990-01-01

213

Emittance characteristics of negative ion beams generated by the sputter technique  

Energy Technology Data Exchange (ETDEWEB)

Average emittance data for ion beams extracted from cesium-sputter negative ion sources equipped with spherical, ellipsoidal, and cylindrical geometry cesium-surface ionizers are presented. The attributes of the respective source geometries are described in terms of their cesium ion optical properties. The results of recent measurement of the emittances of momentum-analyzed beams extracted from the ellipsoidal geometry source are also presented. These measurements indicate the presence of a species-dependent effect. The effect is believed to be attributable to differences in the energy spreads of the respective negative ion beams introduced by the sputter generation process. 11 refs., 8 figs.

1989-01-01

214

Collisional transport in a plasma with steep gradients  

Energy Technology Data Exchange (ETDEWEB)

The validity is given to the newly proposed two {delta}f method for neoclassical transport calculation, which can be solve the drift kinetic equation considering effects of steep plasma gradients, large radial electric field, finite banana width, and an orbit topology near the axis. The new method is applied to the study of ion transport with steep plasma gradients. It is found that the ion thermal diffusivity decreases as the scale length of density gradient decreases, while the ion particle flux due to ion-ion self collisions increases with increasing gradient. (author)

1999-06-01

215

The Study of Phosphors Efficiency and Homogeneity using a Nuclear Microprobe  

Energy Technology Data Exchange (ETDEWEB)

Ion Beam Induced Luminescence (IBIL) and Ion Beam Induced Charge Collection (IBICC) have been applied in the study of the luminescence emission efficiency and investigation of the homogeneity of the luminescence emission in phosphors. The IBIL imaging was performed by using sharply focused ion beams or broad/partially-focused ion beams. The luminescence emission homogeneity in samples was examined to reveal possible distributed crystal-defects that may lead to the inhomogeneity of the luminescence emission in samples.The purpose of the study is to search for suitable luminescent thin films that have high homogeneity of luminescence emission, large IBIL efficiency under heavy ion excitation, and can be placed as a thin layer on the top of microelectronic devices to be analyzed with Ion Photon Emission Microscopy (IPEM). The emission yield was found to be low for ...

2000-12-08

216

Production of intense negative ion beams in magnetically insulated diodes  

Energy Technology Data Exchange (ETDEWEB)

Production of intense negative ion beams in magnetically insulated diodes was studied in order to develop an understanding of this process by measuring the ion-beam parameters as a function of diode and cathode plasma conditions in different magnetically insulated diodes. A coral diode, a racetrack diode, and an annular diode were used. The UCI APEX pulse line, with a nominal output of 1MV, 140kA, was used under matched conditions with a pulse length of 50 nsec. Negative-ion intensity and divergence were measured with Faraday cups and CR-39 track detectors. Cathode plasma was produced by passive dielectric cathodes and later, by an independent plasma gun. Negative-ion currents had an intensity of a few A/cm{sup 2} with a divergence ranging between a few tenths milliradians for an active TiH{sub 2} plasma gun and 300 milliradians for a passive polyethelene cathode. Negative ions were ...

1988-01-01

217

Intense negative-ion beams extracted from an ECR ion source coupled to a charge exchange canal  

Energy Technology Data Exchange (ETDEWEB)

Electron cyclotron resonance (ECR) ion sources possess several advantages over ion sources conventionally used for injectors of electrostatic accelerators: improved reliability, high efficiency, simplicity, and the capability of generating bright, high-current ion beams. We have adapted a high-current ECR source originally developed as an injector for a CW RFQ proton linac to serve as a source of intense negative-ion beams for the Tandem Accelerator Superconducting Cyclotron (TASCC) facility at Chalk River. The range of ion species of the source has been extended from H{sup 1+} alone up to Bi{sup 1+}, with both gaseous and nonvolatile feeds. Two intense negative-ion beams of He{sup -} and O{sup -} have been generated so far with the source coupled to a standard charge-exchange canal. We foresee no major problems generating a broad range of negative ...

1993-07-01

218

Intense negative-ion beams extracted from an ECR ion source coupled to a charge exchange canal  

International Nuclear Information System (INIS)

Electron cyclotron resonance (ECR) ion sources possess several advantages over ion sources conventionally used for injectors of electrostatic accelerators: improved reliability, high efficiency, simplicity, and the capability of generating bright, high-current ion beams. We have adapted a high-current ECR source originally developed as an injector for a CW RFQ proton linac to serve as a source of intense negative-ion beams for the Tandem Accelerator Superconducting Cyclotron (TASCC) facility at Chalk River. The range of ion species of the source has been extended from H1+ alone up to Bi1+, with both gaseous and nonvolatile feeds. Two intense negative-ion beams of He- and O- have been generated so far with the source coupled to a standard charge-exchange canal. We foresee no major problems generating a broad range of negative ions with this ...

1993-09-22

219

Effect of Al and Be ions pre-implantation on formation and growth of helium bubbles in SiC/SiC composites  

Energy Technology Data Exchange (ETDEWEB)

The effect of Al and Be ions pre-implantation on microstructural change and, the formation and growth of He bubbles in SiC/SiC composite was investigated. Four kinds of ion implanted specimens were prepared with 100 appm Al, 1000 appm Al, 100 appm Be and 1000 appm Be implanted. No microstructural change was observed in the matrices and fibers of SiC/SiC composites implanted with Al or Be ions up to 1000 appm. The un-implanted and Al or Be pre-implanted SiC/SiC composites were simultaneously irradiated to 10 dpa using triple ion-beams (6.0-MeV Si{sup 2+}, 1.0-MeV He{sup +} and 340-keV H{sup +}) at 1000 deg. C. Helium bubbles were formed in every matrix and fiber irradiated by triple ion-beams. The size of He bubbles in the matrix was increased by implanting Al or Be ions and increased with increasing amount of implanted Al or Be ions. The ...

2007-03-15

220

Effect of Al and Be ions pre-implantation on formation and growth of helium bubbles in SiC/SiC composites  

International Nuclear Information System (INIS)

The effect of Al and Be ions pre-implantation on microstructural change and, the formation and growth of He bubbles in SiC/SiC composite was investigated. Four kinds of ion implanted specimens were prepared with 100 appm Al, 1000 appm Al, 100 appm Be and 1000 appm Be implanted. No microstructural change was observed in the matrices and fibers of SiC/SiC composites implanted with Al or Be ions up to 1000 appm. The un-implanted and Al or Be pre-implanted SiC/SiC composites were simultaneously irradiated to 10 dpa using triple ion-beams (6.0-MeV Si"2"+, 1.0-MeV He"+ and 340-keV H"+) at 1000 deg. C. Helium bubbles were formed in every matrix and fiber irradiated by triple ion-beams. The size of He bubbles in the matrix was increased by implanting Al or Be ions and increased with increasing amount of implanted Al or Be ions. The size of He ...

2007-03-01

221

Spectroscopic investigation of the charge dynamics of heavy ions penetrating solid and gaseous targets  

Energy Technology Data Exchange (ETDEWEB)

This thesis presents the study of the slowing down process of fast heavy ions inside matter. In the framework of this research, the influence of the target density on the stopping process is investigated. Experiments on the interaction of {sup 48}Ca{sup 6+}-{sup 48}Ca{sup 10+} and {sup 26}Mg{sup 5+} ion beams with initial energies of 11.4 MeV/u and 5.9 MeV/u with solid and gaseous targets have been carried out. A novel diagnostic method, X-ray spectroscopy of K-shell projectile radiation, is used to determine the ion charge state in relation to its velocity during the penetration of fast heavy ions inside the stopping material. A spatially resolved analysis of the projectile and target radiation in solids is achieved for the first time. The application of low-density silica aerogels as stopping media provided a stretching of the ion stopping length by 20 - 100 times in comparison ...

2007-01-15

222

Halogens for negative ion beams and ion-ion plasmas  

International Nuclear Information System (INIS)

Negative ions have attractive features as drivers for inertial confinement fusion, because they will avoid electron cloud effects, and could be efficiently photodetached to neutrals after the final focus, which could also be beneficial in heating warm dense matter targets. The halogens have large electron affinities, and thus should be able to produce high current densities of relatively robust negative ions. Recent experiments comparing chlorine beams to argon beams using the same source, extraction optics, and diagnostics have demonstrated that Cl"- beams can be produced with similar emittance to Ar"+ beams, and with about 34 the current density from the same configuration. The observed effective beam temperature of about 13eV, and the similarity of current densities show that negative halogen beams can meet the current density and emittance requirements of heavy ion fusion. The near equivalence of the Cl"- and ...

2007-07-01

223

Donnan dialysis with ion-exchange membranes. 3: Diffusion coefficients using ions of different valence  

Energy Technology Data Exchange (ETDEWEB)

Donnan dialysis with ion-exchange membranes was studied under various kinds of experimental conditions using ions of different valences. The diffusion coefficients (D{sub d}) of various kinds of ions in the ion-exchange membrane were obtained by curve fitting an equation derived from the mass balance to three kinds of Donnan dialytic experiments. It was found that the value of D{sub d}/D{sub s} using D{sub d} of monovalent ions in Donnan dialysis with a set of monovalent feed ions and bivalent driving ions was 1/175, where D{sub s} represents a diffusion coefficient in solution. D{sub s} was calculated from the Nernst-Einstein equation substituted by the ionic conductance of ions at infinite dilution in water. Using D{sub d} of bivalent ions in Donnan dialysis with the same set led to a D{sub ...

1999-01-01

224

Trace analysis in cadmium telluride by heavy ion induced X-ray emission and by SIMS  

International Nuclear Information System (INIS)

The possibilities of using both selective heavy ion induced X-ray emission and secondary ion mass spectroscopy (SIMS), for the identification of impurities present at low concentrations in cadmium telluride are examined. The relative concentrations of the impurities along CdTe crystals have been determined by exciting the X-ray emission of the elements in several slices with Ar and Kr ions and by comparing the relative characteristic X-ray emission yields. As a consequence of the quasimolecular inner shell ionization mechanism in heavy ion-atom collisions, Ar and Kr ions allow a strong excitation of the main impurities seen by SIMS namely Si, Cl and Ge, As, with only a minor contribution of Cd and Te. From the changes of the concentrations of the various impurities along the crystal, informations about segregation coefficients and compensation can be obtained.

2007-02-01

225

Temperature measurement of 6He?+? ions confined in a transparent Paul trap  

British Library Electronic Table of Contents (United Kingdom)

The LPCTrap setup is a transparent Paul trap dedicated to the measurement of the ??? correlation coefficient a ?? in the ? decay of trapped radioactive nuclides. In a first experiment, the system has been used to record ?105 coincidences between the ? particles and recoiling ions emitted from the decay of 6He?+? ions. The analysis of the collected data has already shown that the size of the 6He?+? ion cloud confined in the Paul trap is a critical parameter, potentially limiting the accuracy on the a ?? measurement. We report here the precise determination of the trapped ion cloud temperature and size. This was performed by extracting the trapped ions toward a position sensitive micro channel plate detector at different phases of the RF driving field. We find a temperature T exp ?= 0.107(7)...

2011-01-01

226

R and D for the development of negative ion beams of halogens  

Energy Technology Data Exchange (ETDEWEB)

Ion beams of halogens can be produced either positively or negatively charged, depending on the employed ion source. At CERN-ISOLDE, although positively charged fluorine and astatine can be obtained from a hot plasma ion source, they are often contaminated by isobars and molecular sidebands. This has generated a request from the scientific community for fluorine and astatine negative ion beams free of contaminants. The high selectivity ensured by the surface ionisation process also makes negative beams of chlorine, bromine and iodine highly attractive. However, the efficiency figures for negative surface ionisation of fluorine and astatine were lower than the ones from the hot plasma. Here we report our R and D on new surface ion sources suitable for the production of negative halogen beams.

2008-10-15

227

Negative-ion based NBI system for JT-60U  

Energy Technology Data Exchange (ETDEWEB)

A 500 keV negative-ion based NBI system is under construction for NB current drive and plasma core heating in high density plasma in JT-60U. Part of the beamline and the high voltage power supply required for a verification test of an ion source was completed in March 1995. After having done a high potential test of the power supply, the negative-ion generation and acceleration tests started in June 1995 aiming at deuterium beams of 500 keV, 22A. In initial experiment, deuterium negative-ion beams of 410 keV, 6.1A (2.5 MW) for 0.2 sec, so far, have been achieved. This is the world highest D{sup {minus}} current and negative ion beam power. The construction of the total system will be completed by the beginning of 1996, and the beam injection will start in March 1996.

1995-12-31

228

Microstructure of c-BN films deposited by IBAD: IR and HREM analyses  

International Nuclear Information System (INIS)

The in-depth distribution of phases in c-BN films deposited by Ion Beam Assisted Deposition (IBAD) at two different ion energy values (300 and 600 eV) was investigated using the quantitative IR transmission measurements and the HREM technique. Whatever the value of the studied ion energies, the characteristic layered morphology of c-BN film is observed including the interfacial sp"2 zone between the substrate and the c-BN volume. In the case of 600 eV ion energy, this interfacial zone is less well-defined in comparison with 300 eV ion energy and the corresponding thickness is more important. Furthermore, the h-BN phase is more diluted within the c-BN film volume showing that the purest phase concentration of c-BN is found for the lowest ion energy, i.e., 300 eV.

1997-04-04

229

Ion-induced phase formation in metal-silicon systems. [Xenon ion implantation effects  

Energy Technology Data Exchange (ETDEWEB)

By using megaelectronvolt /sup 4/He ion backscattering techniques and transmission electron microscopy, the authors have investigated the interactions of ion beams with thin film structures in a number of silicide-forming systems. The mixed layer was found to be an equilibrium compound for near-noble metals and an amorphous phase for refractory metals. Differences in behavior have also been observed in near-noble metal systems. For palladium, the Pd/sub 2/Si phase grew with ion dose and remained crystalline up to high dose. For nickel, the compound Ni/sub 2/Si was formed initially and became amorphous on prolonged irradiation. All the results indicate the significance of atomic mobility at target temperatures in determining the phase formation and in explaining the sensitivity of the silicides to ion bombardment.

1985-01-11

230

Ion nitriding of aluminium  

Energy Technology Data Exchange (ETDEWEB)

The present study is devoted to the investigation of the mechanism of aluminium nitriding by a technique that employs implantation of low-energy nitrogen ions and diffusional transport of atoms. The nitriding of aluminium is investigated, because this is a method for surface modification of aluminium and has a potential for application in a broad spectrum of fields such as automobile, marine, aviation, space technologies, etc. However, at present nitriding of aluminium does not find any large scale industrial application, due to problems in the formation of stoichiometric aluminium nitride layers with a sufficient thickness and good quality. For the purposes of this study, ion nitriding is chosen, as an ion beam method with the advantage of good and independent control over the process parameters, which thus can be related uniquely to the physical properties of the resulting layers. Moreover, ion ...

2002-09-01

231

Ion implantation into concave polymer surface  

Energy Technology Data Exchange (ETDEWEB)

A new technique for ion implantation into concave surface of insulating materials is proposed and experimentally studied. The principle is roughly described by referring to modifying inner surface of a PET (polyethylene terephthalate) bottle. An electrode that is supplied with positive high-voltage pulses is inserted into the bottle. Both plasma formation and ion implantation are simultaneously realized by the same high-voltage pulses. Ion sheath with a certain thickness that depends on plasma parameters is formed just on the inner surface of the bottle. Since the plasma potential is very close to that of the electrode, ions from the plasma are accelerated in the sheath and implanted perpendicularly into the bottle's inner surface. Laser Raman spectroscopy shows that the inner surface of an ion-implanted PET bottle is modified into DLC (diamond-like carbon). Gas permeation ...

2006-01-15

232

Fractionation of isotopes of alkali metals and alkaline earth metals in ion exchange chromatography  

International Nuclear Information System (INIS)

Fractionation of isotopes of the alkali metals and the alkaline earth metals in ion exchange chromatography of their chlorides was studied. The heavier isotopes of potassium and rubidium were found to be preferentially fractionated into the ion exchanger phase while the lighter isotopes of lithium, magnesium, calcium and strontium were enriched in the exchanger phase. This can be interpreted as a resultant of the relative significance of isotope effect upon dehydration and isotope effect accompanying the phase change of the hydrated metal ion. Found was no evidence of anomalous isotope effect attributable to the odd-even difference in mass number of isotopes. Based on the spectroscopic and solution chemical data (experimental and theoretical), the isotopic reduced partition function ratios of the hydrated alkaline metal ions and stretching force constants of metal ion-hydrating ...

233

Experimental determination of a species-dependent effect in the transverse emittances of sputter-generated negative-ion beams  

Energy Technology Data Exchange (ETDEWEB)

We report experimental evidence of a previously unseen species-dependent effect in the transverse emittances of momentum-analyzed {sup 28}Si{sup {minus}}, {sup 58}Ni{sup {minus}}, and {sup 197}Au{sup {minus}} negative-ion beams generated by cesium-ion sputtering. The differences in the emittances are found to be principally correlated with differences in the energy spreads in the respective ion beams, which have their origins in the sputter-ejection negative-ion formation process. The experimental equipment and techniques utilized for emittance data acquisition and analysis, and evidence for a species-dependent effect in the emittances and brightnesses of the subject ion beams, are presented in this paper.

1990-02-01

234

Enhanced catalytic activity of Fe bimetallic modified PAN fiber complexes prepared with different assisted metal ions for degradation of organic dye  

British Library Electronic Table of Contents (United Kingdom)

Two transition metal ions (Cu^2^+ and Co^2^+) and two rare earth metal ions (Ce^3^+ and La^3^+) were used as the assisted metal ions, respectively to prepare the transition metal and rare metal assisted Fe bimetallic amidoximated polyacrylonitrile (AO-PAN) fiber complexes. And their coordination configuration and visible light adsorption properties were examined by coordination number determination and UV-vis-DRS. Then the catalytic performance of these complexes was evaluated as the heterogeneous Fenton catalysts in Rhodamine B degradation by changing the nature and dosage of the assisted ions added. The results indicated that the incorporation of the assisted metal ions led to Fe bimetallic AO-PAN complexes with the more unsaturated configurations than Fe monometallic AO-PAN complex due ...

2011-01-01

235

Effects of indirect ionization on the charge state distributions observed with highly charged ion sources  

Energy Technology Data Exchange (ETDEWEB)

Presently, most charge state distributions produced with highly charged ion sources are predicted with models that approximate the ionization process with the Lotz formula. The Lotz ionization cross sections decrease approximately geometrically with increasing charge state except for ions with very few vacancies, for ions with very few electrons, and for electron impact energies which barely exceed the ionization energy. The geometrical decrease causes these models to predict a maximum abundance for most of the charge states, which is only weakly dependent on the charge state. Experimental results, however, yield much higher abundances for ions with an empty M shell than ions with a partly filled M shell. This difference is explained with indirect ionization processes that are neglected by the Lotz approximation, and normally can be neglected for the ionization of the L shell, but ...

2000-02-01

236

EBIT - Electronic Beam Ion Trap: N Divison experimental physics annual report 1995  

Energy Technology Data Exchange (ETDEWEB)

The multi-faceted research effort of the EBIT (Electron Beam Ion Trap) program in N-Division of the Physics and Space Technology Department at Lawrence Livermore National Laboratory (LLNL) continues to contribute significant results to the physical sciences from studies with low energy very highly charged heavy ions. The EBIT program attracts a number of collaborators from the US and abroad for the different projects. The collaborations are partly carried out through participating graduate students demonstrating the excellent educational capabilities at the LLNL EBIT facilities. Moreover, participants from Historically Black Colleges and Universities are engaged in the EBIT project. This report describes EBIT work for 1995 in atomic structure measurements and radiative transition probabilities, spectral diagnostics for laboratory and astrophysical plasmas, ion/surface interaction studies, electron-ion ...

1996-10-01

237

Collisional Cooling of Negative Ion Beams  

Science.gov (United States)

Investigations have been conducted to determine the feasibility of using collisional cooling for reducing the energy spreads and, consequently, the emittances of negative-ion beams. We have designed a gas-filled RF-quadrupole ion cooler equipped with provisions for retarding energetic negative ion beams to energies below thresholds for electron detachment at injection and for re-acceleration to high energies after the cooling process. The device has been used to cool O{sup -} and F{sup -} ion beams with initial energy spreads, {Delta}E > 10 eV to final energy spreads, {Delta}E {approx} 2 eV FWHM. Overall transmission efficiencies of {approx}14% for F{sup -} beams have been obtained. Experimental results show that electron detachment is the major loss mechanism for negative ions.

2001-06-29

238

Collisional Cooling of Negative Ion Beams  

Energy Technology Data Exchange (ETDEWEB)

Investigations have been conducted to determine the feasibility of using collisional cooling for reducing the energy spreads and, consequently, the emittances of negative-ion beams. We have designed a gas-filled RF-quadrupole ion cooler equipped with provisions for retarding energetic negative ion beams to energies below thresholds for electron detachment at injection and for re-acceleration to high energies after the cooling process. The device has been used to cool O{sup -} and F{sup -} ion beams with initial energy spreads, {Delta}E > 10 eV to final energy spreads, {Delta}E {approx} 2 eV FWHM. Overall transmission efficiencies of {approx}14% for F{sup -} beams have been obtained. Experimental results show that electron detachment is the major loss mechanism for negative ions.

2001-06-29

239

Applications of CR-39 for the estimation of biological effects of heavy ion irradiation to DNA and living cells  

Energy Technology Data Exchange (ETDEWEB)

We present two applications of CR-39 to estimate biological effects of heavy ion irradiation. The accurate measurement of fluence of ions using CR-39 is indispensable to calculate the action cross sections for biological effects. Ions with 6 MeV/n at the Medium Energy Beam Course, HIMAC (NIRS) were extracted to the air, and degraded with the air. DNA and living cells were irradiated by ions with various specific energies at several air columns along with the Bragg curve. DNA strand breaks and cell killing were measured and the results were converted to the action cross sections using the fluence measured with CR-39 at the irradiation positions. Another example of the application of CR-39 is to identify whether the ions with a specific energy pass through the cell or stop within the cell. (author)

2001-10-01

240

Adsorption of iodine ions in modified activated charcoal  

Energy Technology Data Exchange (ETDEWEB)

Shaped activated charcoal is modified by 02 and N2 processing for producing coal compounds with higher acidic or basic properties. Nitrated activated charcoal has properties of a weak anionite with a substantially increased ion exchange capacity with an increase in the concentration of the hydrogen ions in the electrolyte and adsorbs iodine ions well from aqueous solutions at a pH of less than 5. A layer of nitrated charcoal is a very effective sorbent in the process of dynamic sorption of iodine anions from acetic solutions of KI. It is also established that the sorption of iodine ions in the activated charcoal modified by 02 occurs in accordance with an ion exchange mechanism (and possibly, selective sorption). This refutes literature data which ascribe the determining participation in the process to the reaction of oxidation of iodides on the surface (Pv) of the coal into free ...

1983-01-01

241

Some fundamental factors in quantitative analysis by ion microanalyzer  

International Nuclear Information System (INIS)

In analysis of hydrogen in metals and alloys by SIMS, control of the hydrogen blank mainly due to residual gases is a persistent problem. Contrarity, this problem becomes less important in case of deuterium analysis. The prescribed amounts of deuterium were introduced into a pure titanium and a beta-titanium alloy (Ti- 6.6wt%Fe) by the gas reaction method. Intensities of the various secondary ions sputtered from each sample were measured by the Hitachi Ion Microanalyzer with primary ions of Ar"+. Energy distributions of the various secondary ion species were measured with the energy window of about 15eV width. The effects of oxygen gas pressure in the target chamber and the bulk deuterium concentration on the shape of energy distribution curves are discussed. For all samples, intensity of D"- ions is higher than that of D"+ ions, especially at higher energy ...

242

Wrinkled hard skins on polymers created by focused ion beam  

UK PubMed Central (United Kingdom)

A stiff skin forms on surface areas of a flat polydimethylsiloxane (PDMS) upon exposure to focused ion beam (FIB) leading to ordered surface wrinkles. By controlling the FIB fluence and area of exposure...Full Text Available

2007-01-23

243

Versatile high intensity plasma sputter heavy negative ion source  

Energy Technology Data Exchange (ETDEWEB)

A multicusp magnetic field plasma surface ion source, normally used for H/sup -/ ion beam formation, has been utilized for the generation of high intensity, pulsed, heavy negative ion beams suitable for a variety of uses including tandem electrostatic accelerator/synchrotron injection applications. Sputter probe voltage limited total ion currents of 5.5, 8.2, 5.1 and 4.5 mA (peak intensity) have been produced from Au, Cu, Ni and CuO sputter probes, respectively. The mass distributions of these ion beams are found to be dominated by Au/sup -/, Cu/sup -/, Ni/sup -/ and O/sup -/ atomic species, respectively. The source offers the interesting prospect of providing cw negative ion beams at mA intensity levels of the commonly used semiconducting material dopants (e.g. B/sup -/, P/sup -/, As/sup -/ and Sb/sup -/) as well as O/sup -/ for isolation barrier formation. ...

1988-07-01

244

The characteristics of ion-beam-induced spontaneous etching of GaAs by low-energy focused ion beam irradiation  

International Nuclear Information System (INIS)

We have investigated the characteristics of ion-beam-induced spontaneous etching (IBISE) of GaAs in Cl_2 ambient by using a Ga-focused ion beam (FIB) with an energy ranging from 3 to 15 keV. The etched depth of the irradiated region was more than 20 times greater than that of unirradiated region. When the sputtered depth by FIB irradiation amounted to around 8 A at each ion energy, the etched depth in Cl_2 ambient for 1 hour became saturated. The saturated etched depths were 450, 550, 750 and 800 A at the ion energy of 3, 5, 10 and 15 keV, respectively. The residual damage of the etched surface was also investigated by photoluminescence (PL) measurement. The maximal PL intensity was obtained at around the threshold dose of IBISE and increased with decreasing ion energy. The full recovery of PL intensity was observed at the ion energy of 3 keV after annealing at ...

245

Temperature-induced opening of TRPV1 ion channel is stabilized by the pore domain  

UK PubMed Central (United Kingdom)

SummaryTRPV1 is the founding and best-studied member of the family of temperature-activated transient receptor potential ion channels (thermoTRPs). Voltage, chemicals, and heat...Full Text Available

2010-06-01

246

Structural aspects of lithium ions hydration in aqueous solutions of electrolytes  

International Nuclear Information System (INIS)

Analysis of results of an investigation into the structure of lithium salt aqueous solutions is presented. An anomaly in lithium ion behaviour in solutions at the structural level is noted. 40 refs., 3 tabs.

247

Sodium ion-dependent amino acid transport in membrane vesicles of Bacillus stearothermophilus.  

UK PubMed Central (United Kingdom)

Amino acid transport in membrane vesicles of Bacillus stearothermophilus was studied. A relatively high concentration of sodium ions is needed for uptake of L-alanine (Kt = 1.0 mM) and L-leucine (Kt...Full Text Available

1991-01-01

248

Sodium ion cycling mediates energy coupling between complex I and ATP synthase  

UK PubMed Central (United Kingdom)

We show here sodium ion cycling between complex I from Klebsiella pneumoniae and the F1F0 ATP synthase from Ilyobacter tartaricus in a reconstituted...Full Text Available

2003-02-04

249

Selection of Inhibitor-Resistant Viral Potassium Channels Identifies a Selectivity Filter Site that Affects Barium and Amantadine Block  

UK PubMed Central (United Kingdom)

BackgroundUnderstanding the interactions between ion channels and blockers remains an important goal that has implications for delineating the basic mechanisms of ion channel function...Full Text Available

250

Role of surface degrees of freedom in grazing heavy ion collisions  

Energy Technology Data Exchange (ETDEWEB)

A survey is given of the influence of surface deformations on heavy ion reactions. Emphasis is put on the effect of zeropoint fluctuations in the entrance channel and on the effect on grazing collisions in terms of an imaginary part of the scattering potential.

1983-11-14

251

Role of surface degrees of freedom in grazing heavy ion collisions  

International Nuclear Information System (INIS)

A survey is given of the influence of surface deformations on heavy ion reactions. Emphasis is put on the effect of zeropoint fluctuations in the entrance channel and on the effect on grazing collisions in terms of an imaginary part of the scattering potential. (orig.).

252

Rhizosphere Acidification by Iron Deficient Bean Plants: The Role of Trace Amounts of Divalent Metal Ions  

UK PubMed Central (United Kingdom)

Rhizosphere acidification by Fe-deficient bean (Phaseolus vulgaris L.) plants was induced by trace amounts of divalent metal ions (Zn, Mn). The induction of this Fe-efficiency reaction...Full Text Available

1989-05-01

253

Research in heavy-ion nuclear physics  

Energy Technology Data Exchange (ETDEWEB)

This report discusses the following topics: Fusion-fission in light nuclear systems; High-resolution Q-value measurement for the {sup 24}Mg+{sup 24}Mg reaction; Heavy-ion reactions and limits to fusion; and Hybrid MWPC-Bragg curve detector development.

1992-01-01

254

Range accuracy in carbon ion treatment planning based on CT-calibration with real tissue samples  

UK PubMed Central (United Kingdom)

BackgroundThe precision in carbon ion radiotherapy depends on the calibration of Hounsfield units (HU) as measured with computed tomography (CT) to water equivalence. This calibration...Full Text Available

255

Proton Transfer Reactivity of Large Multiply Charged Ions  

UK PubMed Central (United Kingdom)

Charge-charge interactions dramatically influence the dissociation and proton transfer reactivity of large multiply protonated ions. In combination with tandem mass spectrometry, proton transfer...Full Text Available

1996-08-01

256

Photocatalytic hydrogen production from solutions of sulfite using platinized cadmium sulfide powder  

Energy Technology Data Exchange (ETDEWEB)

Platinized cadmium sulfide powder suspended in a solution of sodium sulfite produces hydrogen efficiently by visible light. Sulfite ions are oxidized to sulfate and dithionate ions. 4 figures.

1983-09-29

257

Parallel helix bundles and ion channels: molecular modeling via simulated annealing and restrained molecular dynamics.  

UK PubMed Central (United Kingdom)

A parallel bundle of transmembrane (TM) alpha-helices surrounding a central pore is present in several classes of ion channel, including the nicotinic acetylcholine receptor (nAChR). We have modeled...Full Text Available

1994-10-01

258

Panel session: Transport of negative ion beams  

Energy Technology Data Exchange (ETDEWEB)

Transport of negative ion beams through plasma is reviewed. The effect of space charge on beam stability and beam emittance is discussed. The approaches to the beam transport problem developed at Los Alamos, Berkeley, Oak Ridge and Culham Laboratory are intercompared. (AIP)

1987-07-30

259

Nanoporous structure formations on germanium surfaces by focused ion beam irradiations  

International Nuclear Information System (INIS)

The formation of porous structures of nanometre size (nanoporous structures) on germanium (Ge) surfaces by focused ion beam (FIB) irradiations was investigated using various FIB conditions such as ion species, irradiation energies, total fluences, fluence rates, and incident angles. FIB-irradiated regions were observed using a scanning electron microscope and an atomic force microscope. It is found that, using a focused Ga ion beam (Ga FIB) at an energy of 100 keV, the irradiated Ge surface swelled up to ion fluence of 2 x 10"1"7 cm"-"2 with nanoporous structures and then was etched for larger fluences. The shape of swollen nanoporous structures depended on the fluence rate and the incident angle of the Ga FIB. However, such porous structures were observed neither for low-energy (15-30 keV) FIB irradiations using Si and Au ions nor for high-energy (200 keV), heavy ...

2007-11-07

260

Metal Ions-Stimulated Iron Oxidation in Hydroxylases Facilitates Stabilization of HIF-1? Protein  

UK PubMed Central (United Kingdom)

The exposure of cells to several metal ions stabilizes HIF-1α protein. However, the molecular mechanisms are not completely understood. They may involve inhibition of hydroxylation by either...Full Text Available

2009-02-01

261

Mesozoic Era of relativistic heavy ion physics and beyond.  

Science.gov (United States)

In order to understand how matter 15 billion years ago in the form of quarks, gluons and leptons at a temperature of 2 (times) 10(sup 12) (degrees)K evolved to become today's Universe, the goal of relativistic and ultra-relativistic heavy ion physics is t...

1994-01-01

262

High intensity inverted sputter source  

Energy Technology Data Exchange (ETDEWEB)

The electrode structure of an inverted cesium sputtering negative ion source has been modified to produce a convergent Cs/sup +/ beam. The intensities of negative ion beams produced with this electrode structure are approximately an order of magnitude greater than previously obtained.

1982-08-15

263

Forward Trafficking of Ion Channels: What the Clinician Needs to Know  

UK PubMed Central (United Kingdom)

Each heartbeat requires precisely orchestrated action potential propagation through the myocardium achieved by coordination of about a million ion channels on the surface of each cardiomyocyte....Full Text Available

2010-08-01

264

Focused ion beam techniques for fabricating geometrically-complex components and devices.  

Energy Technology Data Exchange (ETDEWEB)

We have researched several new focused ion beam (FIB) micro-fabrication techniques that offer control of feature shape and the ability to accurately define features onto nonplanar substrates. These FIB-based processes are considered useful for prototyping, reverse engineering, and small-lot manufacturing. Ion beam-based techniques have been developed for defining features in miniature, nonplanar substrates. We demonstrate helices in cylindrical substrates having diameters from 100 {micro}m to 3 mm. Ion beam lathe processes sputter-define 10-{micro}m wide features in cylindrical substrates and tubes. For larger substrates, we combine focused ion beam milling with ultra-precision lathe turning techniques to accurately define 25-100 {micro}m features over many meters of path length. In several cases, we combine the feature defining capability of focused ion beam bombardment with ...

2004-03-01

265

Focused ion beam processes for high-T/sub c/ superconductors  

International Nuclear Information System (INIS)

Focused ion beam (FIB) processes have been developed for Y--Ba--Cu--O superconductor films. A Y--Cu liquid metal ion source has been fabricated, using a Y_6_7 --Cu_3_3 eutectic alloy as the ion source. As-sputtered Y--Ba--Cu--O film etch rate ratios to GaAs(100) and Si(100) substrates are 0.28 and 1.4 for 130-keV Au"+ FIB ion etching, respectively. Y--Ba--Cu--O submicron patterns have been demonstrated by using FIB lithography and Cl_2 reactive ion beam etching. Moreover, a Y--Ba--Cu--O superconducting line with 4-#mu#m linewidth has been fabricated by annealing an as-sputtered Y--Ba--Cu--O line pattern. T/sub c/ control of Y--Ba--Cu--O film has been achieved by 200-keV Ne"+, using conventional ion implantation and 300 keV Si"+"+ FIB ion implantation.

266

Fabrication of nanometer structures by means of a fine-focused ion beam  

International Nuclear Information System (INIS)

Focused Ion Beams are an important approach for nanostructure fabrication in the semiconductor industry and material sciences. Applications in sputtering and ion induced deposition of materials are investigated. The IMSA FIB system equipped with the high resolution Orsay Physics CANION M31plus ion column with current densities up to 10 A/cm"2 including a gas injection system is applied. In this work the ion beam induced chemical vapour deposition of tungsten, wherefore tungsten hexacarbonyl as precursor gas is used for a first investigation. Conductive tungsten-nanowires with smallest cross-section upon a substrate of Si and SiO_2 are produced. The ion beam parameters of this focused ion beam system are optimized for the metal deposition. A short insight in the theory of layer nucleation and growth induced by the ion beam during the metal ...

2000-03-01

267

Equilibrium, thermodynamic and kinetic studies for the biosorption of aqueous lead(II) ions onto the seed husk of Calophyllum inophyllum  

British Library Electronic Table of Contents (United Kingdom)

Biosorption of lead(II) ions from aqueous solution onto the seed husk of Calophyllum inophyllum was investigated in a batch system. Equilibrium, thermodynamics and kinetic studies were conducted by considering the effects of pH, initial metal ion concentration, contact time, and temperature. The results showed that the uptake of the metal ions increased with increase in initial metal ion concentration. The pH for optimum adsorption was 4 for the Pb(II) ions (q=4.86mg/g and 97.2% adsorption). Langmuir isotherm described the biosorption of Pb(II) ions onto the biomass (R^2=0.9531) better than the Freundlich model (R^2=0.7984), and the Temkin model (R^2=0.8761). Biosorption kinetics data obtained for the metal ions sorption were fitted using pseudo-first-order and pseudo-second-order. It was ...

2010-01-01

268

Effect of mineral compounds in phosphoric acid polluted by sulfide ions on corrosion of nickel  

Energy Technology Data Exchange (ETDEWEB)

The inhibiting effects of two mineral compounds on corrosion of nickel in phosphoric acid (H[sub 3]PO[sub 4]) polluted by sulfide ions (S[sup 2[minus

1999-06-01

269

Drift compression and final focus of intense heavy ion beams  

Energy Technology Data Exchange (ETDEWEB)

The longitudinal and transverse dynamics of a heavy ion fusion beam during the drift compression and final focus phase is studied. A lattice design with four time-dependent magnets is described that focuses the entire beam pulse onto a single focal point with the same spot size.

2003-05-01

270

Dose verification of helical tomotherapy intensity modulated radiation therapy planning using 2D-array ion chambers  

UK PubMed Central (United Kingdom)

Purpose:To investigate the clinical usage of dose verification of Helical Tomotherapy plans by using 2D-array ion chambers, and to develop an efficient way to validate the dose delivered...Full Text Available

271

Developments of heavy-ion gas detectors at LNL  

Energy Technology Data Exchange (ETDEWEB)

The most important developments in gaseous detectors at LNL are reviewed. Some aspects of timing, pulse height and position resolutions of avalanche counters are reported. The experimental work on heavy-ion identification by Bragg curve spectroscopy is summarized.

1984-05-01

272

Controlling Gas-Phase Reactions for Efficient Charge Reduction Electrospray Mass Spectrometry of Intact Proteins  

UK PubMed Central (United Kingdom)

Charge reduction electrospray mass spectrometry (CREMS) reduces the charge states of electrospray-generated ions, which concentrates the ions from a protein into fewer peaks spread over a larger...Full Text Available

2005-11-01

273

Artificial receptor for peptide recognition in protic media: The role of metal ion coordination  

International Nuclear Information System (INIS)

The production of molecularly imprinted polymers (MIPs) for the recognition of C-terminal cholecystokinin pentapeptide (CCK-5) in the presence of metal ion is reported. The MIPs were produced under the same molar ratio of template to monomers (acrylamide, N,N'-methylene bisacrylamide) in the presence or absence of nitrilotriacetic acid-nickel (Ni-NTA) complex. Scanning electron microscopy images of MIPs were obtained in an attempt to correlate the adsorption characteristics with polymer's morphology. Subsequently Ni2+ was removed and substituted by other divalent ions such as Mg2+, Fe2+, Zn2+, Co2+ and Cu2+. It was found that polymers containing the metal ion complex with the order Fe-NTA, Ni-NTA and Cu-NTA presented lower dissociation constant values than the rest thus exhibiting stronger guest binding activity. The percentage of theoretical maximum binding sites Bmax was almost the same for these ...

2008-08-25

274

Annealing behavior of radiation damages in metal-silicides  

International Nuclear Information System (INIS)

The annealing behavior of the radiation damage in epitaxial Pd_2Si and NiSi_2 films on Si, due to the implantation of 100 keV Ar ions, is investigated by using the channeling technique with "4He ions. (U.K.).

275

A novel approach for predicting the uptake and toxicity of metallic and metalloid ions  

UK PubMed Central (United Kingdom)

Electrostatic nature of plant plasma membrane (PM) plays significant roles in the ion uptake and toxicity. Electrical potential at the PM exterior surface (ψ0o) influences...Full Text Available

2011-03-01

277

Turbidimetric determination of sulfite ion in inhibited ethylene glycol-water solutions  

Science.gov (United States)

Turbidimetric method for determining sulfite in inhibited ethylene glycol-water solutions

1970-01-01

279

The virtual fast-ion loss detector  

International Nuclear Information System (INIS)

English 2009 p. 79 Ukraine Brudgam, M. Lauber, Ph. Garcia Munoz, M.

2009-09-21

280

The interaction of fast N"+_2 ions with a Ni(111) surface  

International Nuclear Information System (INIS)

In the context of sputtering experiments, studying the back-scattering of fast ion beams is a useful way to study inelastic ion-surface interactions, since then the trajectories and energies of the particles are well defined. This same argument holds for the scattering of fast molecular ions. We give a short account of our experiment where N"+_2 was scattered from a Ni(111) surface. The measured energy distributions of scattered N atoms are discussed with regard to vibrational and rotational energy transfer during scattering. (G.Q.).

1986-02-01

281

Study of physical properties of protons and "1"2C ions in medical application  

International Nuclear Information System (INIS)

Depending on their unique physical properties, proton and heavy ions have taken an irreplaceable role in modern means of tumor treatment. One-step process and two-step process physical models were employed to explain the mechanism of ion energy loss. The transport process of proton and "1"2C in water was simulated by Geant4 toolkit to study the physical properties of ion beam. The calculation results were discussed, which showed the advantages and disadvantages of proton and "1"2C in the medical application. (authors)

2009-06-01

282

State of molybdenum ions in ultrastable Y zeolite  

Energy Technology Data Exchange (ETDEWEB)

The methods of diffuse-reflection optical spectroscopy and EPR were used to study the state of molybdenum in catalysts prepared by impregnating ultrastable zeolite with molybdenum salt solutions and by mixing in the solid phase with MoCl/sub 5/. It has been shown that molybdenum introduced into zeolites in small amounts is found basically in the form of isolated hexavalent ions of molybdenum. In addition, Mo/sup 5 +/ and Mo/sup 4 +/ ions are also present. Heteropolycompounds also form. The molybdenum ions are most readily reduced in the zeolite prepared by impregnation with a solution of ammonium paramolybdate.

1987-10-01

283

Sheath characteristic in ECR plasma nitriding  

International Nuclear Information System (INIS)

The sheath plasma characteristics changing with the negative bias applied to the substrate during electron cyclotron resonance plasma nitriding are studied. The sheath characteristics obtained by a Langmuir single probe and an ion energy analyzer show that when the negative bias applied to the substrate is increasing, the most probable energy of ions in the sheath and the full width of half maximum of ions energy distribution increase, the thickness of the sheath also increases, whereas the saturation current of ion decreases. It has been found from the optical emission spectrum that there are strong lines of N_2 and N_2"+. Based on the experiment results the mechanism of plasma nitriding is discussed

2001-04-01

284

Separation of platinum group metal ions by Donnan dialysis  

Energy Technology Data Exchange (ETDEWEB)

Separations of metal ions on the basis of Donnan dialysis across anion-exchange membranes should be possible if the receiver electrolyte composition favors the formation of selected anionic complexes of the sample metal ions. Moreover, such a separation has the possibility of being better suited from some applications than batch or column experiments with anion-exchange resins. The above hypothesis are tested on the platinum-group metal ions, Pt(IV), Rh(III), Pd(II), Ir(III), and Ir(IV). 13 references, 4 tables.

1985-10-01

285

Selective detection of hexachromium ions by localized surface plasmon resonance measurements using gold nanoparticles/chitosan composite interfaces.  

Science.gov (United States)

Selective removal of hexavalent chromium ions from aqueous solutions using a chitosan/gold nanoparticles composite film was demonstrated. Localized surface plasmon resonance (LSPR) was used to measure the interface stability and detect the incorporation of chromium ions over time. The effects of pH, ethylenediaminetetraacetic acid (EDTA), and various foreign ions such as trivalent chromium, sodium, calcium, phosphate, sulfate and chloride on the adsorption of hexavalent chromium were investigated. PMID:19381379

2009-03-04

286

Radio frequency He/sup -/ source and a source of negative ions by cesium sputtering  

Energy Technology Data Exchange (ETDEWEB)

Two sources of negative ions are described. An rf source produces up to 14 ..mu..A beams of He/sup -/ by charge exchange in Rb vapor. The other Source of Negative Ions by Cesium Sputtering (SNICS) produces a wide variety of negative ion beams in the ..mu..A range. Two important features of SNICS are its simple, compact construction and its very good beam emittance (2 to 4..pi..mm mrad MeV/sup 1/2/). Both sources have lifetimes >200 hours and they are used extensively on the Wisconsin EN tandem.

1981-04-01

287

Quality assurance requirements in a clinical heavy ion therapy unit  

International Nuclear Information System (INIS)

German 2006 [1 p.] Germany Karger, Christian Heeg, Peter Jaekel, Oliver

2006-03-13

288

Plasma production and flow in negative ion beams  

Science.gov (United States)

Plasma generated in low-density vapor by a negative ion beam has been studied experimentally and computationally. We show that space charge neutralization of the beam occurs at very low vapor density, and that correspondingly the electron density may be much less than the beam and plasma ion densities. When there is a large local gas density, as in a charge changing cell, the resulting high electron density is also localized to the same region. Therefore, very few electrons will reach a negative ion accelerator even if it is placed one or two beam diameters from such a cell.

1977-09-21

289

Plasma flow measurement using directional Langmuir probe under weakly ion-magnetized conditions  

Energy Technology Data Exchange (ETDEWEB)

It is both experimentally and theoretically demonstrated that ion flow velocity at an arbitrary angle with respect to the magnetic field can be measured with a directional Langmuir probe. Based on the symmetry argument, we show that the effect of magnetic field on directional probe current is exactly canceled in determining the ion flow velocity, and obtain the generalized relation between flow velocity and directional probe currents valid for any flowing direction. The absolute value of the flow velocity is determined by an in situ calibration method of the probe. The applicability limit of the present method to a strongly ion-magnetized plasma is experimentally examined. (author)

2000-07-01

290

Pairing effect in the nucleon transfer processes in quasi-elastic heavy ion scattering  

International Nuclear Information System (INIS)

... range krypton 86 reactions molybdenum 92 target probability quasi-elastic

1987-04-14

291

Laser photoelectron spectroscopy of ions. Progress report, August 1, 1982-July 31, 1983  

Energy Technology Data Exchange (ETDEWEB)

We have undertaken a program which measures the photoelectron spectra of negative-ion beams. This experiment has afforded us direct information about these ions and the corresponding neutral radicals. Several ions and numerous radicals are believed to be crucial intermediates in combustion processes and flame chemistry. We have fabricated a spectrometer which directly measures electron affinities (EA). Knowledge of the EA and gas-phase acidity of a radical has enabled us to deduce several radical heats of formation and bond strengths.

1983-03-01

292

Ion motion and finite temperature effect on relativistic strong plasma waves  

CERN Document Server

The influence of motion of ions and electron temperature on nonlinear one-dimensional plasma waves with velocity close to the speed of light in vacuum investigated. It is shown that although the wavebreaking field weakly depends on mass of ions, the nonlinear relativistic wavelength essentially changes. The nonlinearity leads to the increase of the strong plasma wavelength, while the motion of ions leads to the decrease of the wavelength. Both hydrodynamic approach and kinetic one, based on Vlasov-Poisson equations, are used to investigate the relativistic strong plasma waves in a warm plasma. The existence of relativistic solitons in a thermal plasma is predicted.

1998-01-01

293

Ion Transport Measurements in a Multi-Dipole Argon Plasma by Broadband Laser Induced Fluorescence  

International Nuclear Information System (INIS)

Argon ion laser induced fluorescence measurements were carried out in a multipolar filament discharge with a broadband diode laser centered on 668 nm, which stimulated a transition from the metastable state in Ar(II) 3d4F7/2 to 4p4D05/2. The intensity of the induced fluorescence at 442 nm was maximized by the optimization of the discharge parameters and the laser power. From the recovery of the background fluorescence after the laser was turned off, the ion diffusion coefficient was deduced and compared with the result inferred from the experiments of ion acoustic wave (IAW) damping.

2009-06-01

295

IFA-2 collective ion accelerator experiments  

Energy Technology Data Exchange (ETDEWEB)

Ion acceleration has now been demonstrated with the IFA-2 collective ion accelerator system. The IFA-2 system is described, photoionization experiments are summarized, and ion results are presented. Using a 1 MeV electron beam and a 30 cm acceleration length, IFA-2 has produced 5 MeV H/sup +/, 10 MeV D/sup +/, and 20 MeV He/sup + +/. This means that accelerating fields of 33 MV/m over 30 cm have been achieved with a controlled collective accelerator for the first time.

1985-10-01

296

High-current negative-ion beam transport  

Energy Technology Data Exchange (ETDEWEB)

The requirements for transporting high-current, negative-ion beams are presented with particular emphasis on applications involving negative-hydrogen-ion beams. In addition to the usual matching and steering problems, particular attention must be paid to beam emittance growth in the transport system. Depending on the application, a number of approaches have been developed using both magnetic and electric lenses. I discuss the design considerations for transporting and matching these beams to radiofrequency quadrupole accelerators, and present a survey of the various types of beamlines now used for negative-ion beams.

1993-01-01

297

High-current negative-ion beam transport  

Energy Technology Data Exchange (ETDEWEB)

The requirements for transporting high-current, negative-ion beams are presented with particular emphasis on applications involving negative-hydrogen-ion beams. In addition to the usual matching and steering problems, particular attention must be paid to beam emittance growth in the transport system. Depending on the application, a number of approaches have been developed using both magnetic and electric lenses. I discuss the design considerations for transporting and matching these beams to radio-frequency quadrupole accelerators, and present a survey of the various types of beamlines now used for negative-ion beams.

1992-10-05

298

High-current negative-ion beam transport  

Energy Technology Data Exchange (ETDEWEB)

The requirements for transporting high-current, negative-ion beams are presented with particular emphasis on applications involving negative-hydrogen-ion beams. In addition to the usual matching and steering problems, particular attention must be paid to beam emittance growth in the transport system. Depending on the application, a number of approaches have been developed using both magnetic and electric lenses. I discuss the design considerations for transporting and matching these beams to radiofrequency quadrupole accelerators, and present a survey of the various types of beamlines now used for negative-ion beams.

1993-04-01

299

High current implantation of negative copper ions into silica glasses  

Energy Technology Data Exchange (ETDEWEB)

High-current implantation of Cu{sup {minus}} ions into silica glasses has been demonstrated using mA-class negative ion beams at 60 keV. Negative ion implantation has an advantage to alleviate specimen charging for insulating substrates and has attained high dose rates, up to 260 {micro}A/cm{sup 2}. Spherical Cu colloids form in the silica glasses without additional thermal annealing. Optical absorption and reflection of the implanted specimens vary with the current density, even at a fixed dose level. A beam-induced surface plasma may affect the high current implantation.

1997-12-01

300

Generation of high-energy electrons and ions at propagation of relativistic laser pulses through supercritical plasma  

International Nuclear Information System (INIS)

In terms of the kinetic theory of the interaction between the high-power short-time laser pulses with plasma based on the propagator plotting for the plasma particle distribution functions one studied the generation of the hot electrons and of the fast ions as the relativistic femtosecond laser pulses travelled through the supercritical density plasma. One performed calculations based on the various values of the laser pulse intensity, types of the multiple-charged ions, the plasma inhomogeneity degree. One studied the acceleration mechanisms both of the plasma electrons and ions

2007-12-01

301

Equilibrium charge and LET of incident heavy ions (Ne and Ar) in hydrogen gas  

Energy Technology Data Exchange (ETDEWEB)

When energetic heavy ions traverse a medium, the amount of energy deposited by the ions is closely related to their effective charges. The charge-state fractions of these beams are obtained by solving rate equations for the electron loss and capture processes. By assuming local balance between electron loss and capture, the charge-state distributions, the averge equilibrium charge q, and other properties are obtained as functions of the incident beam velocity. The LET (linear energy transfer) of Ne and Ar ions with energies between 0.01 and 100 MeV/amu is calculatedted using their average equilibrium charge.

1984-09-01

304

Effect of discharge voltage on an ion sheath formed at a grid in a multi-dipole discharge plasma  

International Nuclear Information System (INIS)

It is experimentally demonstrated that a relatively strong ion-rich sheath formed at a fixed negative bias of the grid can be changed to a rather weak ion sheath (sheath potential weakly retards electrons) only by increasing the discharge voltage in the system. At sufficiently high negative grid bias, an increase of discharge voltage enhances the ion collection current at the grid. An explanation is put forward in support of this experimental observation. A slight density enhancement with a fall in plasma electron temperature is also observed with the increasing negative grid bias. (authors)

2008-03-01

305

Collective ion acceleration in systems with a virtual cathode  

International Nuclear Information System (INIS)

The current status of research and development in the realm of physics and technology of collective ion acceleration in systems with a virtual cathode (VC) is reviewed. Three major acceleration methods and devices developed on their basis are considered: reflex triodes and their modifications, gas-filled vircators, and vacuum vircators with a Luce diode. Experimental data are outlined and the principal physical models interpreting these data are described. New ion acceleration techniques whose realization involves the production and disappearance of the VC are also discussed. All methods of collective ion acceleration are compared and the possible ways for the further development of this promising scientific field are highlighted. (reviews of topical problems)

2002-11-30

306

Coherent correlation enhancement of outer shell photoionization cross sections of alkali-like ions  

Energy Technology Data Exchange (ETDEWEB)

An alkali-like ion interaction with inner electrons of an alkali-like ion leads to a significant increase in the photoionization cross section of the outer s electron. This occurs not only for ground-state ions with one s electron in the outer shell, but also when the outer s electron is in an excited state. The reason for this amplification, in addition to coherent enhancement in summing of the correlation amplitudes, is that the zero in the direct amplitude occurs below threshold. This leads to a constructive interference with the correlation amplitude above the photoionization threshold, in contrast to a destructive interference in the case of a neutral atom with the same electronic configuration, for which the zero occurs above threshold. Results of this research were published.

1995-08-01

307

Chromatographic separation of lithium isotopes by hydrous manganese(IV) oxide  

Energy Technology Data Exchange (ETDEWEB)

Separation of lithium isotopes was investigated by chemical ion exchange with a hydrous manganese(IV) oxide ion exchanger using an elution chromatography. The capacity of manganese(IV) oxide ion exchanger was 0.5 meq/g. The heavier lithium isotope was enriched in the solution phase, while the lighter isotope was enriched in the ion exchanger phase. The separation factor was determined according to the method of Glueckauf from the elution curve and isotopic assays. The separation factor of {sup 6}Li{sup +} -{sup 7}Li{sup +} isotope pair fractionation was 1.018.

2001-06-01

309

A study of crystalline and stress behavior in oxide films prepared by ion assisted deposition  

International Nuclear Information System (INIS)

One of the main problems related to optical thin film materials used in high power laser environments is the catastrophic damage caused to them due to laser irradiation. While the influence of ion bombardment on the optical properties of oxide thin films is now a well understood subject, the morphology and crystalline behaviour of these films under ion incidence is not so well studied. Hence, it is of great importance to investigate the effects of ion bombardment during growth on the microstructure and crystalline behaviour of oxide materials.

1994-10-24

310

--No Title--  

Science.gov (United States)

Nitrogens, Sulfurs, Isotopes, and Hydrocarbons Gases Elements Ions and Inorganic Acids Organic Compounds Co-eluting Organics Hopanes, Cholestanes, and Sterols Pesticides,...

2011-08-19

311

The production and destruction of negative ions  

Energy Technology Data Exchange (ETDEWEB)

During the present grant period we have continued our study of the photodetachment of atomic negative ions using cross-beam photoelectron detachment spectroscopy. The experimental technique involves the measurement of, under conditions of good energy and angular resolution, kinetic energies, yields and angular distributions of photoelectrons ejected from the interaction region between perpendicularly crossed laser and negative ion beams. 6 figs.

1990-01-01

312

Spontaneous radiation emission during penetration of ions in solids  

International Nuclear Information System (INIS)

In this work, the principal continuum radiative emission processes, which occur during the penetration of ions in solids or gases, are resumed. The characteristics of the following processes are discussed: secondary electron bremsstrahlung (SEB), atomic bremsstrahlung (AB), and internuclear bremsstrahlung (INB). Recent advances of the ion channeling effects in crystal solids on the spontaneous radiative spectra are exposed. (A.C.A.S.).

1988-09-25

313

Review of ion-based coating processes derived from the cathodic arc  

International Nuclear Information System (INIS)

The cathodic vacuum arc provides a means of producing large currents of positive ions of a wide variety of materials. These ions can be utilized to produce coatings with improved properties such as higher density and adhesion. The processing is particularly useful in reactive deposition of ceramic coatings having excellent stoichiometry. In this review, emerging aspects of the technology are emphasized.

314

Removal of radioactive ions from nuclear waste solutions by electrodialysis  

International Nuclear Information System (INIS)

Removal of radioactive ions was studied from low and medium level radioactive waste solutions by electrodialysis using ion exchange membranes. The test solutions contained "1"3"7Cs"+, "1"0"6Ru"3"+ or fission products (F.P.) as active ions and NaCl, Na_2SO_4 or Ca(NO_3)_2 as inactive coexisting salts. The decontamination factor of the active ions was in the order: "1"3"7Cs"+ (greater than 99%) > "9"0Sr"2"+ > F.P. > "1"0"6Ru"3"+. The dialysis time required to attain the saturation was the shortest for monovalent cations K"+, Cs"+ and Na"+, intermediate for divalent cation Sr"2"+, and the longest for trivalent cation Ru"3"+. The ratio of the decontamination factor of an active ion eta sub( a) to the desalination factor of an inactive ion eta sub( b) was nearly equal to unity for "2"4Na, "4"2K, "1"3"7Cs and "9"0Sr. On the other hand, the apparent selective ...

315

Radiation damage on amorphous metals. [Helium ion, neutron and gamma ray irradiation  

Energy Technology Data Exchange (ETDEWEB)

The structural variations of amorphous metals, such as Pd/sub 80/Si/sub 20/, with irradiation of helium ion, neutron, and gamma ray have been mainly pursued by the method of X-ray diffraction and thermal analysis. It should be noticed that the amorphous metals show a radiation resistance, that is, no remarkable structural changes under helium ion, neutron, and gamma ray irradiation.

1982-04-01

316

Quantum Discrete Fourier Transform in an Ion Trap System  

International Nuclear Information System (INIS)

We propose two schemes for the implementation of quantum discrete Fourier transform in the ion trap system. In each scheme we design a tunable two-qubit phase gate as the main ingredient. The experimental implementation of the schemes would be an important step toward complex quantum computation in the ion trap system.

2007-06-15

317

Photodetachment of negative ion beams in the presence of a background gas  

Energy Technology Data Exchange (ETDEWEB)

To suppress space charge blowup in an ion beam passing through a photoneutralizer, it is necessary to introduce some background gas. An analysis is presented of the neutralization of a high-energy, >200-keV negative deuterium ion beam, exposed to photodetachment while in the presence of deuterium. With a gas thickness of <0.01 Torr.cm, the neutral fraction in the output beam is found to be about the same as that gotten from the photoneutralizer operating in vacuum. Neutral atom beam injection for plasma heating is discussed.

1987-03-01

318

Peculiarity of counterion - polyion interactions in aqueous solutions of copolymers of acrylamide with cadmium acrylate  

Energy Technology Data Exchange (ETDEWEB)

Binding of Cd/sup 2 +/ ions in aqueous solutions of statistical copolymers of acrylamide with cadmium acrylate with different content of ionogenic groups in copolymers was investigated by polarography, conductometry, viscometry and dialysis. It is shown that the degree of binding of Cd/sup 2 +/ ions increases with increasing of the content of ionogenic groups in the copolymer and with decreasing of ionic strength of the solution. The values of the degree of binding of Cd/sup 2 +/ ions obtained by polarography and dialysis show satisfactory agreement.

1984-02-01

319

Neutralization of negative ion beams by a gas dynamic laser  

Energy Technology Data Exchange (ETDEWEB)

The possibility of applying the near infrared gas dynamic lasers (GDL) for neutralization of negative ion beams is examined. A criterion of neutralization is suggested. The use of the criterion makes it possible to select an optically active medium for a negative ion neutralization. To demonstrate the method media containing hydrohalogens as imitating molecules are taken. ((orig.))

1994-11-01

320

Implantation-plasma treatment of martensitic steel and titanium alloy  

Energy Technology Data Exchange (ETDEWEB)

One of the effective methods of deep modification of the surface of steels and alloys is the combination of ion implantation and plasma nitriding. In this work, the long-range effect is demonstrated in the case of combination of the effect of high- and low-energy ions of nitrogen on a martensitic steel for each ion implantation is usually not effective, and a titanium alloy used widely in industry.

2001-07-01

321

High-resolution primary ion beam probe for SIMS  

Energy Technology Data Exchange (ETDEWEB)

High-brightness negative ion beams, especially O{sup -} beams, from a compact gaseous plasma source are studied to evaluate the suitability for high-resolution SIMS. Ion-optical calculations are made using the beam parameters from the new source. Results suggest that sub-100 nm spot with O{sup -} beam current of 10 pA is achievable. Beam focusing, the resulting beam current distributions at the target and the expected instrumental performance are discussed.

2004-06-15

322

Estimation of the mean distance of closest approach of some heavy metal ions in aqueous solutions: some experimental and theoretical calculations  

British Library Electronic Table of Contents (United Kingdom)

The estimation of numerical values of the mean distance of closest approach of ions, a, of heavy metal ion salts in aqueous solutions, determined from activity coefficients, as well as from different theoretical approaches, is presented and discussed.

2011-01-01

323

Double-electron-capture cross section for I/sup +/ in a magnesium-vapor target  

Energy Technology Data Exchange (ETDEWEB)

Measurements of the double-electron-capture process in which a positive ion of iodine becomes a negative ion in a single collision with a magnesium atom are reported between 20 and 90 keV. The cross section is comparable to that for the rare gases and not as large as might be expected from a two-valence-electron atom. This process is probably insignificant in the production of negative ion beams using a magnesium-vapor target.

1987-06-15

324

Development of laser-ion beam photodissociation methods  

Energy Technology Data Exchange (ETDEWEB)

During this report period our research efforts have concentrated on studies of the dissociation reactions of model peptides and other biologically important molecules. In addition, a considerable amount of research effort has been directed toward improving the apparatus used for laser-ion beam photodissociation. The instrumental improvements include some changes on the original apparatus, but most of this effort involved designing a second generation laser-ion beam photodissociation instrument.

1990-08-01

325

Depth Profiling of N and C in Ion Implanted ZnO and Si Using Deuterium Induced Nuclear Reaction Analysis  

International Nuclear Information System (INIS)

Nuclear Reaction Analysis (NRA) with deuteron ion beams has been used to probe for ion implanted nitrogen and carbon with high sensitivity in zinc oxide and silicon single crystals. The ion implanted N was measured using 1.4 MeV deuteron ion beams and was found to be in agreement with calculated values. The limit of detection for N in ZnO is 8x1014 ions cm-2. Raman measurements of the ion implanted samples showed three additional modes at 275, 504, and 644 cm-1 compared to the un-implanted ZnO crystals. The NRA and Raman results provided information on the N concentration, depth distribution, and structural changes that occur in dependence on the nitrogen ion fluences. The deuterium induced 12C(d,p)13C reaction was used to measure the carbon impurity/dose in ion implanted silicon. It was found that the use of a large ...

2008-11-03

326

Collective acceleration of electrons and ions in a high current relativistic electron beam. Final report  

International Nuclear Information System (INIS)

The original purpose of this research was an investigation into the use of slow space charge waves on weakly relativistic electron beams for ion acceleration. The work had three main objectives namely, the development of a suitable ion injector, the growth and study of the properties of slow space charge waves on an electron beam, and a combination of the two components parts into a suitable proof of principle demonstration of the wave accelerator. This work focusses on the first two of these objectives.

327

Cesium ion desorption ionization with Fourier transform mass spectrometry  

International Nuclear Information System (INIS)

Cesium ions (Cs"+) are used for the production of the feed ions necessary to obtain Fourier transform mass spectra (FTMS). The molecule chosen for the initial study of this Cs"+ desorption ionization (DI-FTMS) was vitamin B-12 because of its nonvolatile, thermally labile character. 21 references.

328

A magnetically insulated negative ion source for neutral beam heating  

Energy Technology Data Exchange (ETDEWEB)

A new, magnetically insulated negative ion source has recently been discovered which can produce pulsed negative ion beams (H/sup -/, Li/sup -/, and C/sup -/) with intensities of 100-300 A/cm/sup 2/ at 1-4 MeV. This source may provide the basis for a high energy neutral beam system for heating large tokamaks.

1983-08-01

329

Uranium hexafluoride production plant decommissioning; Descomissionamento de uma usina de producao de hexafluoreto de uranio  

Energy Technology Data Exchange (ETDEWEB)

The Institute of Energetic and Nuclear Research - IPEN is a research and development institution, located in a densely populated area, in the city of Sao Paulo. The nuclear fuel cycle was developed from the Yellow Cake to the enrichment and reconversion at IPEN. After this phase, all the technology was transferred to private enterprises and to the Brazilian Navy (CTM/SP). Some plants of the fuel cycle were at semi-industrial level, with a production over 20 kg/h. As a research institute, IPEN accomplished its function of the fuel cycle, developing and transferring technology. With the necessity of space for the implementation of new projects, the uranium hexafluoride (UF{sub 6}) production plant was chosen, since it had been idle for many years and presented potential leaking risks, which could cause environmental aggression and serious accidents. This plant decommission required accurate planning, as this work had not been carried out in Brazil before, for this type of facility, and ...

2008-07-01

330

Study of superficial films and of electrochemical behaviour of some nickel base alloys and titanium base alloys in solution representation of granitic, argillaceous and salted ground waters  

Energy Technology Data Exchange (ETDEWEB)

The corrosion behaviour of the stainless steels 304, 316 Ti, 25Cr-20Ni-Mo-Ti, nickel base alloys Hastelloy C4, Inconel 625, Incoloy 800, Ti and Ti-0.2% Pd alloy has been studied in the aerated or deaerated solutions at 20/sup 0/C and 90/sup 0/C whose compositions are representative of interstitial ground waters: granitic or clay waters or salt brine. The electrochemical techniques used are voltametry, polarization resistance and complexe impedance measurements. Electrochemical data show the respective influence of the parameters such as temperature, solution composition and dissolved oxygen, addition of soluble species chloride, fluoride, sulfide and carbonates, on which depend the corrosion current density, the passivation and the pitting potential. The inhibition efficiency of carbonate and bicarbonate activities against pitting corrosion is determined. In clay water at 90/sup 0/C, Ti and Ti-Pd show very high passivation aptitude and a broad passive potential ...

1985-01-01

331

Semi-empirical simulation of thermoluminescent response under different filter geometries; Simulacao semi-empirica da resposta termoluminescente sob diferentes geometrias de filtro  

Energy Technology Data Exchange (ETDEWEB)

Many thermoluminescent materials has been developed and used for photon personal dosimetry but no one has all desired characteristics alone. These characteristics include robustness, high sensitivity, energy photon independence, large range of photon energy detection, good reproducibility, small fading and simple glow curve with peaks above 150 deg C. Calcium Sulfate Dysprosium doped (CaSO{sub 4}:Dy) phosphor Thermoluminescent Dosimeter (TLD) has been used by many laboratories, mainly in Brazil and India. Another interesting phosphor is Calcium Fluoride (CaF{sub 2}). These phosphor advantages begin to be more required and its disadvantages have became more apparent, in a global market more and more competitive. These phosphors are used in environmental and area monitoring, once they present more sensibility than other phosphors, like LiF:Mg. Theirs mainly disadvantage is a strong energetic dependence response, which must be corrected for theirs application in the ...

2006-07-01

332

Preliminary investigation of /sup 252/Cf-driven neutron noise analysis for subcritical fuel solution systems  

Energy Technology Data Exchange (ETDEWEB)

A method for determining the reactivity of highly subcritical systems of fissile material, using neutron-noise power spectral densities in conjunction with a /sup 252/Cf source, had previousy been tested in two fast reactor critical assemblies (a mockup of the Fast Flux Test Facility reactor and unreflected enriched uranium metal assemblies) and one thermal reactor (a light-water moderated and reflected lattice of Oak Ridge Research Reactor fuel elements). The last-mentioned test demonstrated the effectiveness of the method in water-moderated systems and thereby prompted the present study of its application to facilities for fuel preparation, reprocessing, and storage. To investigate the applicability of this method to facilities for fuel preparation, reprocessing, and storage, limited experiments were performed with a uranyl fluoride solution. The Los Alamos National Laboratory SHEBA facility, an unreflected cylindrical tank (56 cm diam), was partially filled with ...

1981-01-01

333

Fluoride complexes of Pt(II) as nucleophiles: activity of PtCl/sub 4//sup 2 -/, PtCl/sub 3/(H/sub 2/O)/sup -/, and PtCl/sub 3/(C/sub 2/H/sub 4/)/sup -/ anions in the oxidative addition of methyl iodide  

Energy Technology Data Exchange (ETDEWEB)

The kinetics of the oxidative addition of CH/sub 3/I to platinum(II) complexes in aqueous solutions of K/sub 2/PtCl/sub 4/ and KPtCl/sub 3/(C/sub 2/H/sub 4/) have been studied by PMR and GLC. The second-order rate constants for the PtCl/sub 3/(H/sub 2/O)/sup -/ and PtCl/sub 4//sup 2 -/ particles are equal to 400 exp(-2.7 x 10/sup 3//T) and 3.18 x 10/sup 10/ exp(-9.2 x 10/sup 3//T) mole/sup -1/ x liter x sec/sup -1/, respectively. The introduction of a ..pi..-acceptor ligand, viz. ethylene, into the coordination sphere of platinum(II) results in a sharp drop in the rate, probably due to a decrease in the electron density on the platinum atom. According to the PMR data, the product of the oxidative addition of CH/sub 3/I to Zeise's salt is a methyl complex of platinum(IV), is identical to the complex obtained by reacting methyl iodide with K/sub 2/PtCL/sub 4/, and does not contain an olefin.

1987-05-01

334

Co-operative downconversion luminescence in Tm3+/Yb3+ : SiO2-Al2O3-LiF-GdF3 glasses  

International Nuclear Information System (INIS)

Oxyfluoride aluminosilicate glasses in the composition of 50SiO2-20Al2O3-20LiF-10GdF3-0.5TmF3-xYbF3 (x = 0, 1.0, 2.5, 5, 7.5, 10, 15, 20, 25 and 30 mol%) have been prepared to study their thermal and optical properties. From the differential thermal analysis measurements, glass transition temperatures and onset crystallization temperatures have been evaluated and from them glass stability factors were calculated. Glass stabilities decreased gradually with fluoride content increment in all the studied glasses. The photoluminescence and decay measurements have also been carried out for all these glasses. In these glasses, an efficient near infrared quantum cutting with optimal quantum efficiency approaching 187% has been demonstrated, by exploring the co-operative downconversion mechanism from Tm3+ to Yb3+, with 467 nm (Tm3+ : 3H6 ? 1G4) excitation wavelength. These glasses are promising materials to achieve high efficiency silicon based solar cells by means of ...

2008-09-07

335

Case report: Denys- Drash syndrome.  

Science.gov (United States)

BACKGROUND: Denys-Drash Syndrome (DDS) is an uncommon disorder that appears sporadically and in rare cases may be inherited as an autosomal dominant trait It manifests either at birth or within the first year of life and typically consists of the triad of congenital nephropathy, Wilms tumour and intersex disorder. CASE REPORT: A 10 year-old Caucasian girl was referred to the Dental Department, at Glasgow Royal Hospital for Sick Children by her Paediatric Nephrologist Consultant. The patient was being teased by her peers over her markedly discoloured teeth. The dental history revealed that the patient was a regular dental attendee from an early age. She was dentally anxious having only experienced dental treatment under general anaesthesia (GA) when she was 4 years old. Apparently her primary dentition also showed a generalised discolouration. TREATMENT: This consisted of multiple visits for diet analysis and tooth brushing instruction with the use of disclosing tablets. Plaque control ...

2007-12-01

336

Air quality monitoring report for Alberta, 1991  

Energy Technology Data Exchange (ETDEWEB)

In 1991, the air quality monitoring program in Alberta consisted of continuous, intermittent, static, portable, mobile, and acid precipitation monitoring networks. The air quality monitoring networks are described and results from the continuous, intermittent, static, and acid precipitation networks are summarized. Regulations and guidelines for individual pollutants are discussed in detail. Pollutants monitored continuously (1-h average basis) include ammonia, CO, coefficient of haze, H{sub 2}S, nitrogen oxides, ozone, SO{sub 2}, and total hydrocarbons. Good air quality was observed most of the time at all continuous monitoring stations in 1991. The frequency of good air quality ratings ranged from 81% at the Edmonton northwest station to 98% at the Fort McMurray station. Intermittent monitoring (every 6th day) was conducted for total suspended particulates and for vinyl chloride monomers in the Fort Saskatchewan area. Chemical analyses of benzo(a)pyrene and lead were performed on ...

1993-08-01

337

Year-1 (heavy-ion) physics with CMS at the LHC  

International Nuclear Information System (INIS)

The plans for the CERN LHC heavy ion program in 2010 are for collisions of lead ions during the month of November at an energy about half of the final 5.5 TeV/nucleon. The advanced preparations are mostly for extrapolations of the measurements at the maximum energy previously available, Au + Au at 0.2 TeV/nucleon. Because of the large increase in energy, surprises can be expected. One new feature made possible by the increased energy and the excellent muon energy resolution of CMS will be the study of the yields of the excited states of the upsilon meson as a function of angle and centrality. Although the main emphasis will be on the QGP formed by the overlapping parts of the Pb ions, the spectator parts and the electromagnetic field outside of the ions, #gamma#-Pb and #gamma##gamma#, are also important.

2010-06-01

338

The study of the ion beam induced swelling in crystalline germanium irradiated by a 30 keV Ga"+ focused ion beam  

International Nuclear Information System (INIS)

The effect of swelling of crystalline Ge irradiated at room temperature with 30 keV Ga"+ focused ion beam (FIB) was studied by means of in situ FIB imaging, atomic force microscopy (AFM) and transmission electron microscopy (TEM). The swelling occurred in the surface region of amorphous damage layer which was formed during ion irradiation. The degree of swelling reaches values up to 10 times for an implantation dose of #approx#10"1"7 ions/cm"2. Cross-secitonal TEM examination showed that the swelling is due to formation of a porous layer with a honeycomb structure. (author). 8 refs., 4 figs.

2005-11-20

339

The effect of solutes on defect distributions and hardening in ion-irradiated model ferritic alloys  

International Nuclear Information System (INIS)

A series of nine model ferritic alloys were ion irradiated at #propor to#300 C using 2.5 MeV He ions to a dose of 1.4 x 10"2"1 ion/m"2, which corresponds to #propor to#0.1 dpa at a depth of 2 #mu#m and #propor to#3.5 dpa at the peak damage region which occurs at about 4 #mu#m deep. The resultant changes in hardness as a function of depth were measured using a Nanoindenter "t"r"a"d"e"m"a"r"k. TEM was used to investigate the defect distributions. The effect of various solutes, Cu and N in particular, but Mn and Ti as well, on the change of hardness and the defect distribution due to the ion irradiation are discussed. (orig.).

340

The distribution profile of the chemical structural changes in ion-irradiated polyolefins  

Energy Technology Data Exchange (ETDEWEB)

The distribution profiles of the chemical structural changes induced in low density polyethylene(LDPE) irradiated by various ion-beams were obtained by micro-FT-IR measurement. Predominant species induced by ion-beam irradiation were trans-vinylene, hydroxyl group and carbonyl group. It was found that the depth profiles of these species resemble the Bragg curve, but they are rather different from the depth profile of the stopping power calculated by TRIM code. The terminal of the chemical reaction was observed to be deeper than the range calculated by TRIM code for all ion particles. This suggests that the energy profile in the region which the energy of the ion particle becomes lower is very complicated. (author).

1996-11-01

341

Studies of the fundamental nature of catalytic acidity, sites, and intermediates: Progress report for period August 1, 1987-July 31, 1988  

Energy Technology Data Exchange (ETDEWEB)

Neopentane, because of its unique structural features, was found to be a useful probe for the assay of the acidity of various zeolites. The C-C bond was attacked by catalyst protons yielding CH/sub 4/ and the isobutyl carbenium ion in equal quantities. The latter either decomposed to produce isobutene or underwent secondary reactions. New avenues for reaction were opened with isobutane. The reaction of the Bronsted protons with the tertiary CH bonds produced H/sub 2/ and the same isobutyl carbenium ion. Hydride ion transfer of the same tertiary hydrogen to existing carbenium ions also occurred and the results showed that about half of the reaction was carried by this pathway. As with Neopentane, the C-C bond could also be attacked yielding the sec-propyl carbenium ion. These tools are being further developed.

1988-06-01

342

Progress of negative-ion based NBI system for JT-60U  

Energy Technology Data Exchange (ETDEWEB)

The operation of the negative ion based NBI system for JT-60U has been progressed since 1996. Most of the efforts in the operation for increasing beam power and energy have been concentrated to get over the troubles, caused by surge energy at the moment of the accelerator break-down, in the ion sources and high voltage power supplies. The ion source for the N-NBI, so far, has accelerated negative ion beams of 14.3 A at 380 keV with deuterium and 18.5 A at 360 keV with hydrogen against the target of 22 A. The neutral beam power injected into JT-60U has already reached 5.2 MW at 350 keV for 0.7 sec with deuterium. (author)

1998-07-01

343

Precise measurement of a focused ion beam profile  

Energy Technology Data Exchange (ETDEWEB)

The profile of focused boron ion beam (FIB) from a liquid metal ion source was determined by MOS device characteristics and resist exposure experiments. A focused boron ion beam was line-scanned into the middle of the channel region along the source to drain direction of a MOSFET, and the effective channel width is determined from electrical measurements. PMMA resist was also exposed by a line-scanned boron FIB and the developed contour was observed by a SEM. The profile of the focused boron ion beam with a diameter of around 0.2 ..mu..m was determined by these two methods and it was found to have about a 1 ..mu..m wide tail at around three orders of magnitude below the peak current density region. The profile difference between the two measurements are attributed to the boron diffusion in silicon by subsequent heat-treatments during device fabrication.

1987-06-01

344

Performance of a Bragg curve detector for heavy ion identification  

Energy Technology Data Exchange (ETDEWEB)

By using Bragg curve spectroscopy, one can measure atomic number and energy of high energy heavy ions stopping in a gas-filled ionization chamber with longitudinal electric field. In this paper, we report on the results obtained with an isobutane filled detector. An energy resolution of 0.8% fwhm and a Z resolution of 2.7% fwhm were achieved for elastically scattered 300 MeV /sup 40/Ar ions. We study the Bragg peak amplitude dependence on the energy of the incoming ions, a dependence presumably due to the Frisch grid screening inefficiency. The corrected Bragg peak spectrum of inelastically scattered 300 MeV /sup 40/Ar ions exhibits a satisfactory Z separation around Z = 18.

1982-12-15

345

Performance of a Bragg curve detector for heavy ion identification  

International Nuclear Information System (INIS)

By using Bragg curve spectroscopy, one can measure atomic number and energy of high energy heavy ions stopping in a gas-filled ionization chamber with longitudinal electric field. In this paper, we report on the results obtained with an isobutane filled detector. An energy resolution of 0.8% fwhm and a Z resolution of 2.7% fwhm were achieved for elastically scattered 300 MeV "4"0Ar ions. We study the Bragg peak amplitude dependence on the energy of the incoming ions, a dependence presumably due to the Frisch grid screening inefficiency. The corrected Bragg peak spectrum of inelastically scattered 300 MeV "4"0Ar ions exhibits a satisfactory Z separation around Z = 18. (orig.).

346

Nanostructuring and hardening of LiF crystals irradiated with 3?15 MeV Au ions  

British Library Electronic Table of Contents (United Kingdom)

Modifications of the structure and mechanical properties in LiF crystals irradiated with MeV-energy Au ions have been studied using nanoindentation, atomic force microscopy and optical spectroscopy. The nanostructuring of crystals under a high-fluence irradiation (above 1013 ions/cm2)?was?observed. Nanoindentation tests show a strong ion-induced increase of hardness (up?to 150?200%), which is related to the high volume concentration of complex color centers, defect aggregates, dislocation loops and grain boundaries acting as strong barriers for dislocations. From the?depth profiling of the hardness and energy loss it follows that both nuclear and electronic stopping mechanisms of MeV Au ions contribute to the creation of damage and hardening. Whereas the electronic stopping is dominating i...

2011-01-01

347

MODELING AN ION EXCHANGE PROCESS FOR CESIUM REMOVAL FROM ALKALINE RADIOACTIVE WASTE SOLUTIONS  

Energy Technology Data Exchange (ETDEWEB)

The performance of spherical Resorcinol-Formaldehyde ion-exchange resin for the removal of cesium from alkaline radioactive waste solutions has been investigated through computer modeling. Cesium adsorption isotherms were obtained by fitting experimental data using a thermodynamic framework. Results show that ion-exchange is an efficient method for cesium removal from highly alkaline radioactive waste solutions. On average, two 1300 liter columns operating in series are able to treat 690,000 liters of waste with an initial cesium concentration of 0.09 mM in 11 days achieving a decontamination factor of over 50,000. The study also tested the sensitivity of ion-exchange column performance to variations in flow rate, temperature and column dimensions. Modeling results can be used to optimize design of the ion exchange system.

2008-08-26

348

Leaching of zinc sulfide by Thiobacillus ferrooxidans: Bacterial oxidation of the sulfur product layer increases the rate of zinc sulfide dissolution at high concentrations of ferrous ions  

Energy Technology Data Exchange (ETDEWEB)

This paper reports the results of leaching experiments conducted with and without Thiobacillus ferroxidans at the same conditions in solution. The extent of leaching of ZnS with Bacteria is significantly higher than that without bacteria at high concentrations of ferrous ions. A porous layer of elemental sulfur is present on the surfaces of the chemically leached particles, which no sulfur is present on the surfaces of the bacterially leached particles. The analysis of the data using the shrinking-core model shows that the chemical leaching of ZnS is limited by the diffusion of ferrous ions through the sulfur product layer at high concentrations of ferrous ions. The analysis of the data shows that diffusion through the product layer does not limit the rate of dissolution when bacteria are present. This suggests that the action of T.ferroxidans in oxidizing the sulfur formed on the particle surface is to remove the barrier ...

1999-12-01

349

Ion-induced phase formation in metal-silicon systems  

International Nuclear Information System (INIS)

By using megaelectronvolt "4He ion backscattering techniques and transmission electron microscopy, the authors have investigated the interactions of ion beams with thin film structures in a number of silicide-forming systems. The mixed layer was found to be an equilibrium compound for near-noble metals and an amorphous phase for refractory metals. Differences in behavior have also been observed in near-noble metal systems. For palladium, the Pd_2Si phase grew with ion dose and remained crystalline up to high dose. For nickel, the compound Ni_2Si was formed initially and became amorphous on prolonged irradiation. All the results indicate the significance of atomic mobility at target temperatures in determining the phase formation and in explaining the sensitivity of the silicides to ion bombardment. (Auth.).

350

Ion temperature anisotropy in high power helium neutral beam fuelling experiments in JET  

Energy Technology Data Exchange (ETDEWEB)

During helium beam fuelling experiments in JET, distinctive anisotropic features have been observed in the velocity distribution function describing both fast and thermal alpha particle populations. During the initial fuelling phase the central helium ion temperature observed perpendicular to the magnetic field is higher than the central electron temperature, while the central helium ion temperature observed parallel to the magnetic field is lower than or equal to the central electron temperature. In order to verify temperature measurements of both perpendicular and parallel lines of sight, other independent methods of deducing the ion temperature are investigated: deuterium ion temperature, deuterium density, comparison with neutron rates and profiles (influence of a possible metastable population of helium). 6 refs., 7 figs.

1994-07-01

351

Ion processing element with composite media  

Energy Technology Data Exchange (ETDEWEB)

An ion processing element employing composite media disposed in a porous substrate, for facilitating removal of selected chemical species from a fluid stream. The ion processing element includes a porous fibrous glass substrate impregnated by composite media having one or more active components supported by a matrix material of polyacrylonitrile. The active components are effective in removing, by various mechanisms, one or more constituents from a fluid stream passing through the ion processing element. Due to the porosity and large surface area of both the composite medium and the substrate in which it is disposed, a high degree of contact is achieved between the active component and the fluid stream being processed. Further, the porosity of the matrix material and the substrate facilitates use of the ion processing element in high volume applications where it is desired to effectively process a high ...

2009-03-24

352

Influence of ion-beam carbon-fiber surface treatment on the angle of wetting by epoxy oligomers  

International Nuclear Information System (INIS)

The influence of the regimes of modification of carbon fibers by an argon ion beam on the change in the angle of their wetting by an epoxy oligomer has been investigated. It has been shown that ion-beam treatment of carbon fibers leads to a considerable decrease in the wetting angles (the difference between the wetting angles for non modified and modified fibers is up to 32.2-38.7). Accordingly, there is also an increase in the value of the equilibrium work of adhesion by 36.2-41.6% in the contact zone. It has been established that ion-beam treatment of carbon fibers by argon ions leads to an increase in the shear strength when microplastics based on them are formed. (authors)

353

Formation of metal-polymer hybrid nanostructures during radiation-induced reduction of metal ions in poly(acrylic acid)-poly(ethylenimine) complexes  

British Library Electronic Table of Contents (United Kingdom)

The formation of nanoparticles during the radiation-induced chemical reduction of silver ions, copper ions, and nickel ions in films based on poly(acrylic acid)-poly(ethylenimine) complexes are studied via electron microscopy. This approach allows preparation of composites containing nanoparticles that are randomly distributed in the polymer matrix and materials with a regular spatial distribution of nanoparticles across the film thickness and in subsurface layers. The structure of metal-polymer hybrid materials is dependent on the irradiation conditions, the type of reduced metal ions, and their initial content in polymer matrices. The ratio between the rate of nucleation and the rate of growth of nanoparticles in the matrices of interpolyelectrolyte complexes depends on the intensity of ...

2011-01-01

354

Focused ion beam system  

Energy Technology Data Exchange (ETDEWEB)

A focused ion beam (FIB) system produces a final beam spot size down to 0.1 .mu.m or less and an ion beam output current on the order of microamps. The FIB system increases ion source brightness by properly configuring the first (plasma) and second (extraction) electrodes. The first electrode is configured to have a high aperture diameter to electrode thickness aspect ratio. Additional accelerator and focusing electrodes are used to produce the final beam. As few as five electrodes can be used, providing a very compact FIB system with a length down to only 20 mm. Multibeamlet arrangements with a single ion source can be produced to increase throughput. The FIB system can be used for nanolithography and doping applications for fabrication of semiconductor devices with minimum feature sizes of 0.1 .mu.m or less.

1999-01-01

355

Focused ion beam system  

Energy Technology Data Exchange (ETDEWEB)

A focused ion beam (FIB) system produces a final beam spot size down to 0.1 {mu}m or less and an ion beam output current on the order of microamps. The FIB system increases ion source brightness by properly configuring the first (plasma) and second (extraction) electrodes. The first electrode is configured to have a high aperture diameter to electrode thickness aspect ratio. Additional accelerator and focusing electrodes are used to produce the final beam. As few as five electrodes can be used, providing a very compact FIB system with a length down to only 20 mm. Multibeamlet arrangements with a single ion source can be produced to increase throughput. The FIB system can be used for nanolithography and doping applications for fabrication of semiconductor devices with minimum feature sizes of 0.1 m or less. 13 figs.

1999-08-31

356

Experiments on determination of damage effect ions "2"2Ne (172 MeV) on UO_2 monocrystals  

International Nuclear Information System (INIS)

Shadow effect was used for investigating damage of uranium dioxide monocrystal. The dependence of shadow minimum parameters on fluence of "2"2Ne ions with 172 MeV energy was followed when detecting fission fragments. Ion dose responsible for sufficient microdamage of lattice structure, included into the classification of heavy ion damage effect on monocrystals was determined. The problem of radiation intensity effect on the character of occurred damages was studied. It was established that macroscopic sample failure, caused by generation of considerable mechanical stresses in monocrystal under beam effect could be observed along with microdamages of lattice structure at ion flux density >10"1"2 cm"-"2Xs"-"1.

357

Effects of ion irradiation on the diffusion of pre-implanted B atoms in crystalline silicon  

International Nuclear Information System (INIS)

N-type crystalline Si (100) implanted with 5 keV B ions was subsequently irradiated with MeV Si, O and F ions. The B atom profiles were measured by means of secondary ion mass spectrometer after the treatment of rapid thermal annealing. The results show that the transient enhanced diffusion of B atoms is effectively limited by the post-implantation of high energy ions at high dose. At the same irradiation conditions, it is found that the existence of a SiO_2 layer in the near surface of Si is even more effective in suppressing the transient enhanced diffusion of the doped B atoms. The results are qualitatively discussed in combination with the analyses of RBS/c measurements and calculation of the DICADA code

2001-12-01

358

Dependence of ion-induced Pd-silicide formation on nuclear energy deposition density  

Energy Technology Data Exchange (ETDEWEB)

Pd/sub 2/Si formation at the Pd-Si interface induced by irradiation with ions having a wide range of nuclear energy of deposition density has been investigated. It is found that the thickness of the silicide layer formed by irradiation is proportional to the ion fluence for irradiation with ions having low energy-deposition densities, while it is proportional to the square root of the fluence for irradiation with ions having energy-deposition densities. The results indicate that Pd/sub 2/Si formation is reaction limited when the energy-deposition density at the interface is low and is diffusion limited when it is high. The results are compared with the phenomenological theory developed by Horino et al. and it is shown that such a dependence of the limiting processes on the energy depositon density is induced when the diffusion is thermally activated while the reaction at the interface is ...

1986-05-01

359

Apparatus for producing controlled positive or negative corona discharge for semiconductor materials processing  

Energy Technology Data Exchange (ETDEWEB)

An apparatus capable of producing current or voltage controlled positive and negative ion beams in 1-atm oxidizing and nonoxidizing ambients between 25/sup 0/ and 950 /sup 0/C is presented. The apparatus utilizes a point-to-plane corona discharge in the gas phase. Room-temperature experiments revealed that the small differences in ion beam shape between the two polarities is primarily due to the difference in applied voltage required to produce the same current for the two polarities. Due to increased ion mobility and decreased threshold voltage at higher temperatures, a slight broadening of the ion beam current-density profiles for both positive and negative ions is predicted.

1984-09-01

360

Annealing of silicon implanted with arsine and hydrogen ions  

Energy Technology Data Exchange (ETDEWEB)

Arsenic and hydrogen ions produced from a mixture of arsine and hydrogen gas were implanted with a dose of 3 x 10{sup 15} As{sup +} ions/cm{sup 2} into silicon using an ion-shower implanter. The dominant ionic species implanted into the silicon were As{sub 2}H{sup +}, AsH{sup +}, H{sub 5}{sup +}, and H{sub 3}{sup +} ions. Arsenic atoms diffused into the silicon with large diffusion coefficients during annealing at 700 and 800 C. However, when the implanted silicon was annealed at 900 C, the arsenic atoms diffused into a deeper region in the silicon with a very small diffusion coefficient that was independent of concentration. (Abstract Copyright [2003], Wiley Periodicals, Inc.)

2003-01-01

361

Adhesion studies of Au films on GaAs using ion-assisted deposition techniques  

International Nuclear Information System (INIS)

This paper reports on a series of experiments performed to examine the ability of ion beam assisted thermal deposition to produce good adhesion of Au metallization on GaAs left-angle 100 right-angle substrates. A study of the influence of Ar ion-assisted thermal deposition of the Au films as well as in situ pre-sputtering of the GaAs surface with low-energy Ar ions prior to thermal deposition, shows that strong adhesion can be achieved without resorting to chemical cleaning. The substrate temperature and the relative flux of Ar ions to incident Au atoms were varied in order to correlate these parameters with film adhesion. The interfaces of films processed under these various conditions were examined by XTEM, RBS and XPS. Orientation texture was studied by x-ray diffraction (XRD).

362

A study on yellow luminescence in O and C ion implanted GaN  

International Nuclear Information System (INIS)

The effects of O and C ion implantation with different implantation doses on the yellow luminescence (YL) from unintentional doped n-type GaN have been studied by the photoluminescence (PL) spectra. O and C ions were implanted in the GaN samples with different doses from 1.0 x l013 to 1.0 x l017cm-2. Post-annealing was done in a quartz open-tube furnace under flowing N2 gas for 30 min at 950 degree C. By comparing with N ion implanted samples, it is assumed that different deep-level centers involving in the YL were produced in GaN after O and C ion implantation. In addition, with a dose of 1017 cm-2, the concentration of deep C centers involving in the YL was enhanced markedly. (authors)

2008-08-01

363

A report on collective ion acceleration via space charge waves on intense relativistic electron beams  

Science.gov (United States)

Collective methods of ion acceleration using intense relativistic electron beams (IREB) have stimulated a great deal of interest in the past few years. The main virtue of an IREB collective ion accelerator is the high internal electric field strength. The primary drawback has been an insufficient ion energy gain or inadequate scaleability. An extensive study for generating a high quality electron beam has been done and is presented in Section 2. In Section 3 an intense ion injector study was conducted by the method of computer simulation. The last addition to the proposal was a design for producing a toroidal magnetic field. This field will be needed in a future study of high energy and high current electron beams.

1981-02-01

364

Steering of high energy negative ion beam and design of beam focusing/deflection compensation for JT-60U large negative ion source  

Energy Technology Data Exchange (ETDEWEB)

A large negative ion source for JT-60U produces high current ion beam from a wide extraction area of 45 cm x 110 cm. On the other hand, a cross-sectional area of the negative ion based neutral beam (NNB) injection port on JT-60U is narrow, about 50 cm x 60 cm. In order to inject the neutral beam at a high geometric efficiency, i.e. to suppress beam loss in the beamline, it is necessary to steer the beam for both compensation of undesirable beam deflection in extractor and focusing of the beam. For the JT-60U, two methods are provided for the required beam steering. Among them the results of beam steering experiment by aperture displacement and the design study are summarized in the present report. The experiment was carried out with 400 keV negative ion source, which has the three stage accelerator of similar structure as the JT-60U ion source, at Negative Ion ...

2000-03-01

365

Pitting and intergranular corrosion resistances of nitrogen ion implanted type 304 stainless steel  

International Nuclear Information System (INIS)

Type 304 stainless steel (SS) specimens sensitised at 873 K and 973 K for 1, 10 and 100 hours respectively were ion implanted using a 150 keV accelerator at an energy of 70 keV in two different doses of nitrogen namely 1 x 10"1"6 to 1 x 10"1"7 ions/cm"2. Ion implantation at 1 x 10"1"6 ions/cm"2 did not show any improvement in pitting resistance, however, the specimens implanted at 1 x 10"1"7 ions/cm"2 showed significant increase in pitting corrosion resistance when potentiodynamic anodic polarisation studies were carried out in acidic chloride medium. For specimens aged at 873 K, nitrogen ion implantation at 1 x 10"1"6 ions/cm"2 increased the intergranular corrosion susceptibility compared to that of unimplanted specimens. However, at the dose of 1 x 10"1"7 ions/cm"2, insignificant IGC attack was noticed. The IGC ...

1998-05-24

366

Study on the energy distribution of ion beams extracted from the sputter-type negative-ion source  

International Nuclear Information System (INIS)

The energy distribution of ion beams is important especially for low energy ion beam applications. The energy distributions of negative-ion beams produced through secondary ion emission by sputtering were measured and compared with theoretically estimated distributions by use of four different negative-ion production probability equations (modified surface ionization model, exponential velocity dependence model, and our modified exponential velocity dependence models (modified decaying factor model and combination model of velocity dependence and surface ionization)). In the measurements, the energy distributions of C"- and Ag"- beams had a peak at a few to several eV and the full width at half maximum were 15 eV and 11 eV, respectively. These results could be well explained by the estimated distributions by virtue of our combination model or the modified surface ionization model. ...

1995-10-23

367

Sample preparation for nanoanalytical electron microscopy using the FIB lift-out method and low energy ion milling  

International Nuclear Information System (INIS)

Thinning specimens to electron transparency for electron microscopy analysis can be done by conventional (2-4 kV) argon ion milling or focused ion beam (FIB) lift-out techniques. Both these methods tend to leave 'mottling' visible on thin specimen areas, and this is believed to be surface damage caused by ion implantation and amorphisation. A low energy (250-500 V) Argon ion polish has been shown to greatly improve specimen quality for crystalline silicon samples. Here we investigate the preparation of technologically important materials for nanoanalysis using conventional and lift-out methods followed by a low energy polish in a GentleMill"T"M low energy ion mill. We use a low energy, low angle (6-8 deg.) ion beam to remove the surface damage from previous processing steps. We assess this method for the preparation of technologically important materials, such ...

2006-02-22

368

Microfabrication processes for high-T_c superconducting films  

International Nuclear Information System (INIS)

Microfabrication processes for Y-Ba-Cu-O films have been investigated, using ion-beam techniques. High-T_c superconducting lines as narrow as 0.8 #mu#m have been fabricated from epitaxial YBa_2Cu_3O_7 _- _y films by Ar ion-beam etching (IBE), combined with focused ion-beam (FIB) lithography. The resulting lines, 1.3 #mu#m wide and 2 mm long, showed a zero resistance temperature of 81 K and a critical current density of 1.9 x 10"4 A/cm"2 at 77.3 K. Maskless etching was carried out using 130-keV au"+ focused ion-beam (FIB) with a 0.1-#mu#m-diameter beam. A 50-nm-thick film was patterned into 0.3-#mu#m-wide lines at a dose of 5 x "1"6 ions/cm"2. In comparison with Ar IBE, Cl_2 reactive ion-beam etching (RIBE) exhibited an enhancement effect in sputtering yield. Ion implantation with 300-keV Si"+ "+ FIB also indicated the possibility to produce ...

369

Measurements of the ion concentrations and conductivity over the Arabian Sea during the ARMEX  

CERN Document Server

Measurements of the small-, intermediate-, and large-ion concentrations and the atmospheric electric conductivity of both polarities have been made over the Arabian Sea on four cruises of ORV Sagarkanya during the Arabian Sea Monsoon Experiment (ARMEX)during the monsoon and pre-monsoon seasons of 2002 and 2003. Seasonally averaged values of the total as well as polar conductivity are much higher during the monsoon than pre-monsoon season. Surprisingly, however, the concentration of small ions are less and those of large and intermediate ions are more during the monsoon than pre-monsoon season. The diurnal variations observed during the pre-monsoon season show that the nighttime small ion concentrations are about an order of magnitude higher than their daytime values. On the contrary, the daytime concentrations of the intermediate and large ions are much higher than those of their ...

2009-01-01

370

Ion beams in silicon processing and characterization  

Energy Technology Data Exchange (ETDEWEB)

General trends in integrated circuit technology toward smaller device dimensions, lower thermal budgets, and simplified processing steps present severe physical and engineering challenges to ion implantation. These challenges, together with the need for physically based models at exceedingly small dimensions, are leading to a new level of understanding of fundamental defect science in Si. In this article, we review the current status and future trends in ion implantation of Si at low and high energies with particular emphasis on areas where recent advances have been made and where further understanding is needed. Particularly interesting are the emerging approaches to defect and dopant distribution modeling, transient enhanced diffusion, high energy implantation and defect accumulation, and metal impurity gettering. Developments in the use of ion beams for analysis indicate much progress has been made in one-dimensional ...

1997-05-01

371

Evolution of surface roughness in silicon X-ray mirrors exposed to a low-energy ion beam  

International Nuclear Information System (INIS)

The possibility of smoothening aspherical X-ray mirrors by irradiation of the surface with a low-energy ion beam is investigated. Nanofocusing being the primary application of these mirrors the ion beam conditions must be optimized to achieve a surface roughness of the order of 0.1-0.2 nm. To address this issue a first study was performed on silicon flat substrates etched using ion energies ranging from 400 to 1200 eV. A second study consisted of eroding the silicon surface while varying the ion grazing incidence angle between 10 deg. and 90 deg. for a fixed value of the ion energy. The surface topography of the samples was characterized at various scales using atomic force microscopy (probed area: 1-10 ?m2), interferential optical microscopy (probed area: 1 mm2) and X-ray scattering (probed area: 100 mm2). Finally, a study by AFM of the evolution of the surface finish level of a ...

2010-05-01

372

Correlation between ion beam parameters and physical characteristics of nanostructures fabricated by focused ion beam  

International Nuclear Information System (INIS)

We report a study of the physical characteristics of the pillars of C, Pt and W grown by 10-30 keV Ga focused ion beam (FIB) as a function of Ga ion flux, and present a quantitative analysis of the elements using energy-dispersive analysis of X-rays (EDAX). All the FIB grown pillars exhibit a rough morphology with whisker like protrusions on the cylindrical surface and broadening of the base as compared to the nominal size. For a constant fluence, the height of the pillar initially increases and then reduces after going through a maximum as a function of ion flux in all the cases. The compositional analysis shows good metallic quality for Pt structures but reveals significant contamination of Ga in C and Ga and C in W structures at higher ion fluxes. Explanation to all these observations has been sought in the light of secondary ion and electron effects and the different processes ...

2008-04-01

373

Comparison of methods to measure the rate of neutral free radical production by photo-deionization of negative ion beams  

Energy Technology Data Exchange (ETDEWEB)

Two measurement methods to determine the rate of neutral free radical production by the photo-deionization of negative ion beams (PDINIB) are introduced. These methods, namely, photoelectron-current measurement by low-frequency electro-modulation probe (PMMP) and measurement of decrease in the negative-ion beam current (DNIC) were employed to evaluate the production rate in a trial surface-processing apparatus developed in the author's laboratory utilizing a steady-flux refined beam of neutral free radicals (RBNR) produced by the PDINIB procedure. A {sup 63}Cu{sup -} negative ion beam of kinetic energy E{sub i} varied up to 15 keV was irradiated with a 514.5 nm visible light beam from a 25 W CW Ar{sup +} ion laser. The detection limit of the production rate by the PMMP setup was as high as 6 x 10{sup 9} s{sup -1} under the condition that E{sub i}=15 keV, the negative-ion ...

2003-05-01

374

Collisional cooling of negative-ion beams  

Energy Technology Data Exchange (ETDEWEB)

Studies have been conducted to determine the feasibility of using collisional cooling for reducing emittances and energy spreads in negative-ion beams to levels commensurate with effective isobaric purification with conventional high-resolution electromagnetic isobar separators as required for use at the Holifield Radioactive Ion Beam Facility (HRIBF). We have designed a gas-filled radio frequency quadrupole ion cooler equipped with provisions for retarding energetic negative-ion beams to energies below thresholds for electron detachment at injection and for re-acceleration to initial energies after the cooling process. The device has been used to cool several ion beams with initial energy spreads, {delta}E>10 eV to final energy spreads, {delta}E{approx}2 eV FWHM, including O{sup -} and F{sup -}. Overall transmission efficiencies of {approx}14% for F{sup -} beams have been ...

2002-01-01

375

Synthesis, structural characterization, and performance evaluation of resorcinol-formaldehyde (R-F) ion-exchange resin  

International Nuclear Information System (INIS)

The 177 underground storage tanks at the DOE's Hanford Site contain an estimated 180 million tons of high-level radioactive wastes. It is desirable to remove and concentrate the highly radioactive fraction of the tank wastes for vitrification. Resorcinol-formaldehyde (R-F) resin, an organic ion-exchange resin with high selectivity and capacity for the cesium ion, which is a candidate ion-exchange material for use in remediation of tank wastes. The report includes information on the structure/function analysis of R-F resin and the synthetic factors that affect performance of the resin. CS-100, a commercially available phenol-formaldehyde (P-F) resin, and currently the baseline ion-exchanger for removal of cesium ion at Hanford, is compared with the R-F resin. The primary structural unit of the R-F resin was determined to consist of a 1,2,3,4-tetrasubstituted resorcinol ring unit ...

2004-09-10

376

Investigation of acoustic waves generated in an elastic solid by a pulsed ion beam and their application in a FIB based scanning ion acoustic microscope  

International Nuclear Information System (INIS)

The aim of this work is to investigate the acoustic wave generation by pulsed and periodically modulated ion beams in different solid materials depending on the beam parameters and to demonstrate the possibility to apply an intensity modulated focused ion beam (FIB) for acoustic emission and for nondestructive investigation of the internal structure of materials on a microscopic scale. The combination of a FIB and an ultrasound microscope in one device can provide the opportunity of nondestructive investigation, production and modification of micro- and nanostructures simultaneously. This work consists of the two main experimental parts. In the first part the process of elastic wave generation during the irradiation of metallic samples by a pulsed beam of energetic ions was investigated in an energy range from 1.5 to 10 MeV and pulse durations of 0.5-5 #mu#s, applying ions with different masses, e.g. ...

377

Improving the mechanical properties of steels using low energy, high temperature nitrogen ion implantation  

Energy Technology Data Exchange (ETDEWEB)

The use of nitrogen ion implantation to increase the surface hardness of structural steels is well documented. Traditionally this involves the use of high energy nitrogen ion beams (approximately 100 keV), with a relatively low beam current density because high energy beams are necessary to produce the required penetration into the material to achieve a significant depth of hardened material. Hardening needs to occur in a region whose size is comparable with the scale of the deformation associated with the tribocontact. 100 keV nitrogen ions typically penetrate into steels only about 0.1 {mu}m and the range of possible tribological applications is thus restricted by this shallow treatment depth. In plasma nitriding processes the nitrogen ions approach the substrate with much lower energies but the ion currents are sufficiently high to cause considerable substrate heating. In this ...

1996-09-01

378

Spectroscopic studies on the interaction of the antibiotic lasalocid A (x-537a) with technetium (V) ions in methanol  

International Nuclear Information System (INIS)

In the present study, the authors examine the interactions of pentavalent technetium ions (TcO/sup 3+/) with the basic form of the lasalocid A in pure methanol solvent and in methanol-water mixtures. There are a number of reasons for such a study. First, the interactions of technetium ions with biologically important compounds are of considerable importance owing to the widespread use of /sup 99m/Tc in diagnostic radio-imaging. Second, lasalocid A is known to transport metal ions across phospholipid bilayer membranes and between the aqueous cores of phospholipid inverse micelles. Third, lasalocid A is known to bind and solubilize metal ions in bulk organic liquid phases. Fourth, the conformation adopted by lasalocid A on interaction with TcO/sup 3+/ appears to be different than those found in most other cases and circumstances. Fifth, it may also be possible to use the competition of TcO/sup 3+/ with ...

379

Soft X-ray holography of FIB nanostructured Co/Pt multilayers  

International Nuclear Information System (INIS)

Focused Ion Beam (FIB) milling is a powerful tool to produce ordered magnetic nanostructures. However, it is impossible to produce out-of-plane magnetized nanoscale structures from multilayer films by direct FIB writing. Co/Pt multilayers exhibit an out-of-plane easy axis due to strong perpendicular interface anisotropy. The interface contribution is known to be very sensitive to high energy ion irradiation. In case of 30 keV Ga ions it needs less than one ion per 100 surface atoms to destroy the perpendicular interface anisotropy. We demonstrate how this problem can be overcome by milling a Co/Pt multilayer, which has been deposited on a SiN membrane, from the rear side, through the SiN. The effect of the ions is determined as a function of applied dose utilizing the domain structure imaged by soft X-ray holography. When the magnetic material is removed we find only a very narrow ...

2009-03-22

380

Promising electrolyte materials for the coming lithium secondary batteries. Lithium ion conductive inorganic solid electrolytes; Jisedai lithium niji denchiyo denkaishitsu. Muki kotai denkaishitsu  

Energy Technology Data Exchange (ETDEWEB)

This paper describes inorganic solid electrolytes from a viewpoint of electrolytes for lithium batteries. Lithium ion conductive inorganic solid electrolytes are largely divided into crystalline and amorphous substances. Crystalline substances are known as LiI and Li3N, and also oxygen acid salt. However, when considering application to a battery, its large grain boundary resistance and electrochemical instability would be a problem. Lithium ion conductive amorphous solid electrolytes are divided into an oxide system and a sulfide system. Since most of them do not contain transition metal elements, they are stable against electrochemical reduction, and ions move isotropically in electrolyte. Therefore, ion conduction paths across the grain boundaries may be connected more easily, forming an electrolyte with low grain boundary resistance. As a result of the efforts of the authors in searching new ...

1997-11-05

381

Processing method and processing facility for carbon steel parts in nuclear power plant  

International Nuclear Information System (INIS)

In a closed circuit formed by bypassing pipelines connected to carbon steel parts, low oxygen coolants pass there through during operation. A solution containing ions of metals more noble than iron are circulated to bring the solution into contact with the carbon steel surface of the inner wall of the parts to form a deposition membrane of the metal more noble than iron on the surface to prevent acceleration of corrosion of the carbon steel parts due to low oxygen coolants. The solution containing ions of metals more noble than iron is a solution of palladium nitrate containing ions of platinum elements. This operation is conducted under a temperature condition of from 50degC to 150degC. In addition, the metal ion concentration of the solution circulating in the closed circuit is measured, it is compared with metal ion concentration previously determined, and the results are feed ...

1996-11-27

382

Position sensitive and Bragg curve spectroscopy detector system for heavy ion reaction studies  

International Nuclear Information System (INIS)

A complete heavy ion identification system in heavy ion reaction studies consists, in general, of: 1) a position sensitive avalanche counter, and 2) ionization chamber to obtain total energy as well as a heavy ion identifier signal (such as the E#DELTA#E signal from a E-#DELTA#E type detector or the height of the Bragg peak that scales as Z of the heavy ion in a Bragg curve ionization chamber). In addition, a time-of-flight information may be needed to resolve the masses of the ions. With this motivation in mind, a composite detector system consisting of a Bragg curve spectroscopy ionization chamber (BCS-IC) and a one dimensional position sensitive parallel grid avalanche counter (XPS-PGAC) has been developed and used successfully at the BARC-TIFR pelletron accelerator facility. The design and performance of this gas detector system are reported. (author). 4 refs., 2 figs.

383

Plasma dynamics in the PF-1000 device under full-scale energy storage: II. Fast electron and ion characteristics versus neutron emission parameters and gun optimization perspectives  

International Nuclear Information System (INIS)

Electron and ion beam dynamics of the PF-1000 facility were investigated for the first time at its upper energy limit (?1 MJ) in relation to neutron emission, the pinch's plasma ('target') characteristics and some other parameters with the help of a number of diagnostics with ns temporal resolution. Special attention was paid to the temporal and the spatial cross correlations of different phenomena. Results of these experiments are in favour of a neutron emission model based on ion beam-plasma interaction with three important features: (1) the plasma target is hot and confined during a few 'inertial confinement times'; (2) the ions of the main part of the beam are magnetized and entrapped around the pinch plasma target for a period longer than the characteristic time of the plasma inductive storage system and (3) ion-ion collisions (both fusion collisions, due to head-on impacts and Coulomb collisions) ...

2007-06-21

384

Modelling discharges in electronegative gases  

Energy Technology Data Exchange (ETDEWEB)

This paper builds on earlier work to give a consistent treatment of the positive column of discharges in electronegative gases covering the transition from collisionless to collisional. In particular it seeks to elucidate the conditions under which there is an ion-ion plasma core surrounded by an electron-ion plasma, and when there is not. The parameters which describe the processes of ionization, attachment, detachment and recombination are related to the central negative ion density relative to the electron density and, where appropriate, the size of the core. The use, by earlier workers, of the Boltzmann approximation to describe the negative ion distribution and to obtain ambipolar diffusion coefficients at higher pressures is shown not to be justified. This leads to the clarification of an inconsistency in the literature. Where possible, the work is related to other recent treatments of the same ...

1999-09-07

385

Low-energy ion-induced electron emission from gas-covered surfaces  

International Nuclear Information System (INIS)

Measurements of ion-induced electron emission have been performed with helium and argon ions with energies between 300 and 900 eV on W, W with 10% Ti, Al, Al with 1% Cu, Al with 1% Si, Si, and Be. This article describes many of the important surface characteristics that influence the ion-induced electron emission. For low-energy ions, the substrate material was found to be less important as the velocity of the incident ion decreased. In the case of incident Ar"+ the substrate material had a negligible effect on the emission for this energy range. The presence of an adsorbed layer enhanced emission in all cases. Heating the substrates resulted in oxidation of the surfaces and a subsequent increase in emission. The electron emission from aluminum samples with smaller grain sizes was higher than samples of identical composition with larger grains. This effect is due to the greater ...

386

Ion transport properties of lithium ionic liquids and their ion gels  

International Nuclear Information System (INIS)

A new series of lithium ionic liquids were prepared by introducing of two electron-withdrawing trifluoroacetyl groups in borate salts containing two methoxy-oligo(ethylene oxide) groups in the structures. Successive substitution reactions of oligo-ethylene glycol monomethyl ether and trifluroacetic acid from LiBH_4 yielded the lithium salts, which were clear and colorless liquids at room temperature. The fundamental physicochemical properties, such as density, thermal property, viscosity, ionic conductivity, self-diffusion coefficients, and electrochemical stability, were measured. The lithium ionic liquids had self-dissociation ability and conducted ions even in the absence of organic solvents. New polymer electrolytes, named 'ion gels', were prepared by radical cross-linking reactions of a poly(ethylene oxide-co-propylene oxide)tri-acrylate macromonomer in the presence the lithium ionic liquid. An increase in the glass transition temperatures ...

2005-06-30

387

Interactions of metal cations with anionic groups on the cell Wall of the macroalga vaucheria sp.  

Energy Technology Data Exchange (ETDEWEB)

The aim of this article was to investigate the interactions of metal cations in aqueous solutions with the biomass of the freshwater macroalga Vaucheria sp. This problem is important when elaborating new applications of biosorption, e.g. the production of mineral feed additives for livestock from the biomass of algae enriched with microelement ions. Potentiometric titration was applied as a quick and cheap screening test to search for new efficient biosorbents. It revealed a variety of functional groups capable of cation exchange on the macroalgal surface, including carboxyl, phosphate, hydroxyl or amino groups. Fourier transform infrared spectroscopy on natural and chromium-loaded Vaucheria sp. confirmed that carboxyl groups played a dominant role in the biosorption. The study also showed that Ca(II), Na(I), K(I), and Mg(II) ions were released from the biomass after biosorption of Cu(II), Mn(II), Zn(II), and Co(II) ions, ...

2010-06-15

388

In-plane aligned CeO[sub 2] films grown on amorphous SiO[sub 2] substrates by ion-beam assisted pulsed laser deposition  

Energy Technology Data Exchange (ETDEWEB)

Both (001)- and (111)-oriented CeO[sub 2] thin films have been grown on amorphous fused silica (SiO[sub 2]) substrates by ion-beam assisted pulsed laser ablation of a polycrystalline CeO[sub 2] target. Using 200 eV Ar[sup +] ions incident at 55[degree] to the substrate normal, the preferred orientation for CeO[sub 2] film growth is (001) at room temperature, but changes to (111) for temperatures [ge]300 [degree]C. Furthermore, the ion-beam assisted CeO[sub 2] films exhibit strong in-plane crystallographic alignment. In contrast, CeO[sub 2] films grown without ion-beam assistance exhibit a mixture of polycrystalline orientations with the relative amounts depending on growth temperature. Under optimum conditions, off-normal-incidence Ar[sup +] ions produce a (111)-oriented crystalline CeO[sub 2] film that is aligned with respect to a single in-plane axis, on an amorphous substrate.

1994-10-17

389

Heavy-ion linear induction accelerators as drivers for inertial fusion power plants  

Energy Technology Data Exchange (ETDEWEB)

A linear induction accelerator that produces a beam of energetic heavy ions (T -- 10 GeV, A -- 200 amu) is a prime candidate as a driver for an inertial fusion power plant. Some early perceptions were that heavy-ion drive fusion would not be cost-competitive with other power sources because of the high cost of the accelerators. However, improved understanding of the physics of heavy-ion transport and acceleration (supported by experimental results), combined with advances in accelerator technology, have resulted in accelerator design costs -- 50% of previous estimates. As a result, heavy-ion drive fusion power plants are now projected to be cost-competitive with other conceptual fusion power plants. A brief formulation of transport and acceleration physics is presented here, along with a description of the induction Linac cost optimization code LIACEP. Cost trends are presented and discussed, along with ...

1988-02-01

390

Heavy-ion linear induction accelerators as drivers for inertial fusion power plants  

International Nuclear Information System (INIS)

A linear induction accelerator that produces a beam of energetic heavy ions (T #approx =# 10 GeV, A #approx =# 200 am#mu#) is a prime candidate as a driver for an inertial fusion power plant. Some early perceptions were that heavy-ion driven fusion would not be cost-competitive with other power sources because of the high cost of the accelerators. However, improved understanding of the physics of heavy-ion transport and acceleration (supported by experimental results), combined with advances in accelerator technology, have resulted in accelerator design costs -- 50% of previous estimates. As a result, heavy-ion driven fusion power plants conceptual fusion power plants. A brief formulation of transport and acceleration physics is presented here, along with a description of the induction Linac cost optimization code LIACEP. Cost trends are presented and discussed, along with specific cost estimates for ...

391

Equilibrium and thermodynamic parameters of single and binary mixture biosorption of lead (II) and copper (II) ions onto Pseudomonas putida: Effect of temperature  

Energy Technology Data Exchange (ETDEWEB)

The biosorption of lead (II) and copper (II) ions, single component and binary systems, by dried P. putida was investigated in a batch system. The effects of initial pH, temperature, initial single and binary mixture concentrations on the biosorption kinetics and equilibrium uptake of each component, both single and binary mixtures were investigated. The bacterial biomass exhibited the highest single and binary lead (II) and copper (II) ions uptake capacity at 25 and 30 deg. C, respectively, the initial pH value of 5.5 and at the initial metal ions concentration of 100 mg dm{sup -3}. The Freundlich and Langmuir adsorption models were used for the mathematical description of the biosorption equilibrium and isotherm constants were evaluated at different temperatures. Adsorption data were well described by the Langmuir model, although they could be modeled by the Freundlich equation. The thermodynamics constants of the ...

2006-07-31

392

Effects of Cr content and the addition of Cr_2O_7"2"- ion on corrosion resistance of stainless steel in nitric acid solutions  

International Nuclear Information System (INIS)

A nitric acid solution containing Cr_2O_7"2"- ion is used for a corrosion test which simulates the condition in a nuclear fuel reprocessing plant. As the effect of Cr content on the corrosion resistance of stainless steel is not yet fully understood in that solution, the effects of Cr content in an alloy and that of Cr_2O_7"2"- ion in nitric acid on the corrosion rate were studied by using electro-chemical measurements. The increase of Cr content reduced the general corrosion rate in nitric acid solution without Cr_2O_7"2"- ion, however it increased that in nitric acid solution containing Cr_2O_7"2"- ion. It is considered that the reversal of the Cr content dependency is due to a rise of the corrosion potential caused by addition of Cr_2O_7"2"- ion to the potential region where a high Cr alloy shows higher anodic dissolution rate than a low Cr content alloy. (author).

393

Development of high power negative ion sources for fusion at JAERI  

Energy Technology Data Exchange (ETDEWEB)

Technologies producing high power negative ion beams have been highly developed in these years at JAERI for use in neutral beam injectors for heating the thermonuclear fusion plasmas. At present, it is possible to produce multi-ampere H-/D- ion beams quasi-continuously at energies more than a few hundred keV with a good beam optics of beamlet divergence of a few milli-radian. Based on these technologies, two R and D projects have been initiated; one is to develop a 22A/500keV/10s D- ion source for the neutral beam injector for JT-60U, and the other is to develop a 1A/1MeV/60s H- ion source to demonstrate high current negative ion acceleration up to the energy of 1MeV, the energy required for the neutral beam injector for International Thermonuclear Experimental Reactor (ITER). (author).

1995-10-01

394

Determination of the thickness and density of the ion bombardment induced altered layer in SiC by means of reflection electron energy loss study  

International Nuclear Information System (INIS)

The steady state surfaces of ion bombarded 3C-, 4H- and 6H-SiC samples were studied by means of reflected electron energy loss spectroscopy (REELS). The REELS exhibit a well-defined loss peak in the region of about 20 eV. The position of the maximum of the loss peak depends on the bombarding ion energy (decreasing with increasing ion energy), and on the primary electron beam energy (increasing with increasing primary energy). This behavior can be explained if we suppose that the plasmon energy in the altered layer (produced by ion bombardment) is different from that of the unaltered bulk. In this case the measured loss peak is the sum of two overlapping plasmon peaks. With modeling the system as a homogeneous altered layer and a homogeneous unaltered substrate the plasmon energy in the altered layer was derived to be 19.8 eV. The large change of the plasmon energy with respect to the bulk value of 23 eV ...

2005-12-15

395

Deposition of Cu film on SiO_2 using a partially ionized beam  

International Nuclear Information System (INIS)

Ion bombardment during deposition can significantly modify the film properties. In the partially ionized beam deposition, ions derived from the depositing material, i.e., the self-ions, are used during deposition. Cu films were deposited on SiO_2 substrates at room temperature using 1% Cu self-ions with an energy ranging between 0--4 keV. We studied the microstructures of the Cu films using x-ray diffraction and transmission electron microscopy, measured the impurity level inside the films using secondary ion mass spectrometry, and performed the resistivity measurements using a four point probe. The results indicate that there is an optimum ion energy around 2 keV at which, the integrated x-ray intensity ratio I(111)/I(200) reaches its maximum value indicating a strong left-angle 111 right-angle texture, while the impurity concentration and resisitivity are ...

1990-01-01

396

Deposition of Cu film on SiO sub 2 using a partially ionized beam  

Energy Technology Data Exchange (ETDEWEB)

Ion bombardment during deposition can significantly modify the film properties. In the partially ionized beam deposition, ions derived from the depositing material, i.e., the self-ions, are used during deposition. Cu films were deposited on SiO{sub 2} substrates at room temperature using 1% Cu self-ions with an energy ranging between 0--4 keV. We studied the microstructures of the Cu films using x-ray diffraction and transmission electron microscopy, measured the impurity level inside the films using secondary ion mass spectrometry, and performed the resistivity measurements using a four point probe. The results indicate that there is an optimum ion energy around 2 keV at which, the integrated x-ray intensity ratio {ital I}(111)/{ital I}(200) reaches its maximum value indicating a strong {l angle}111{r angle} texture, while the impurity concentration and ...

1990-05-01

397

Deposition of Cu film on SiO sub 2 using a partially ionized beam  

Science.gov (United States)

Ion bombardment during deposition can significantly modify the film properties. In the partially ionized beam deposition, ions derived from the depositing material, i.e., the self-ions, are used during deposition. Cu films were deposited on SiO{sub 2} substrates at room temperature using 1% Cu self-ions with an energy ranging between 0--4 keV. We studied the microstructures of the Cu films using x-ray diffraction and transmission electron microscopy, measured the impurity level inside the films using secondary ion mass spectrometry, and performed the resistivity measurements using a four point probe. The results indicate that there is an optimum ion energy around 2 keV at which, the integrated x-ray intensity ratio {ital I}(111)/{ital I}(200) reaches its maximum value indicating a strong {l angle}111{r angle} texture, while the impurity concentration and ...

1990-05-01

398

Contribution to the study of sputtering and damage of uranium dioxide by fast heavy ions; Contribution a l'etude de la pulverisation et de l'endommagement du dioxyde d'uranium par les ions lourds rapides  

Energy Technology Data Exchange (ETDEWEB)

Swift heavy ion-solid interaction leads in volume to track creation and on the surface to the ejection of particles into the vacuum. To learn more about initial mechanisms of track formation, we are focused on the sputtering of uranium dioxide by fast heavy ions. This present study is exclusively devoted to the influence of the electronic stopping power on the emission of neutral particles and especially on their angular distribution. These measurements are completed by those of the ions emitted from UO{sub 2} targets bombarded with swift heavy ions. The whole experimental results give access to: i) the nature of the sputtered particles; ii) the charge state of the emitted particles; iii) the direction of ejection of the sputtered particles ; iv) the sputtering yields deduced from the angular distributions. These results are compared to the prediction of the sputtering models proposed in the literature ...

2001-03-01

399

Biosorption of cadmium(II), zinc(II) and lead(II) by Penicillium simplicissimum: Isotherms, kinetics and thermodynamics  

Energy Technology Data Exchange (ETDEWEB)

The isotherms, kinetics and thermodynamics of Cd(II), Zn(II) and Pb(II) biosorption by Penicillium simplicissimum were investigated in a batch system. The effects of pH, initial metal ions concentration, biomass dose, contact time, temperature and co-ions on the biosorption were studied. Adsorption data were well described by both the Redlich-Peterson and Langmuir model. Chemical ion-exchange was found to be an important process based on free energy value from Dubini-Radushkevich isotherm for all metal ions. The results of the kinetic studies of all metal ions at different temperature showed that the rate of adsorption followed the pseudo second-order kinetics well. The thermodynamics constants {delta}G{sup o}, {delta}H{sup o} and {delta}S{sup o} of the adsorption process showed that biosorption of Cd(II), Zn(II) and Pb(II) ions on Penicillium simplicissimum ...

2008-12-30

400

Biomimetic metal-sorbing vesicles for continuous extraction of heavy metal ions from dilute solution  

Energy Technology Data Exchange (ETDEWEB)

Biomimetic vesicle media which can selectivity extract and concentrate heavy metals (e.g., Pb{sup 2+}) from dilute solutions of 5 ppm and less have been prepared. At a concentration of only 1% 2/v, these non-covalently assembled, unilamellar, surfactant vesicles provide approximately 1,000m{sup 2} of exposed membrane surface area per liter of suspension which gives rise to very rapid rates of metal ion extraction. To facilitate the selective transport of heavy metal ions through the ion impermeable vesicle wall, the vesicles are doped with lipophilic ionophores, both natural and synthetic. In addition, the metal chelating agent, nitrolotriacetate, is encapsulated in the aqueous vesicle core to provide the driving force for metal ion uptake and concentration. Concentration factors in excess of 1000 fold have been observed. Metal-sorbing surfactant vesicles measuring approximately 100 nm in diameter are ...

1993-12-31

401

A proton nuclear magnetic resonance investigation of the anion Bohr effect of human normal adult hemoglobin  

International Nuclear Information System (INIS)

High-resolution proton nuclear magnetic resonance spectroscopy has been used to investigate the molecular mechanism of the Bohr effect of human normal adult hemoglobin in the presence of two allosteric effectors, i.e., chloride and inorganic phosphate ions. The individual hydrogen ion equilibria of 22-26 histidyl residues of hemoglobin have been measured in anion-free 0.1 M HEPES buffer and in the presence of 0.18 M chloride or 0.1 M inorganic phosphate ions in both deoxy and carbonmonoxy forms. The results indicate that the #beta#2-histidyl residues are strong binding sites for chloride and inorganic phosphate ions in hemoglobin. The affinity of the #beta#2-histidyl residues for these anions is larger in the deoxy than in the carbonmonoxy form. Nevertheless, the contribution of these histidyl residues to the anion Bohr effect is small due to their low pK value in deoxyhemoglobin in anion-free solvents. ...

402

Ultrasensitive laser isotope analysis in an ion-storage ring  

Energy Technology Data Exchange (ETDEWEB)

We propose a novel method for ultrasensitive isotope analysis that combines magnetic mass selection, resonant charge-exchange neutralization, and resonant laser ionizaion. Our method attains high isotopic abundance selectivity by means of continuous multistage separation of ions stored in a small ring. For the environmentally interesting case of /sup 90/Sr versus /sup 88/Sr we estimate that sensitivity better than 10/sup -15/ for a throughput of 10/sup 13/ atoms/sec and an efficiency (after the ion source) greater than 10% are readily achievable.

1985-09-01

403

Titanate nanotubes as superior adsorbents for removal of lead(II) ions from water  

British Library Electronic Table of Contents (United Kingdom)

Titanate nanotubes were hydrothermally synthesized and their adsorption performances for lead(II) ion removal were studied. The results showed that titanate nanotubes ruptured in the adsorption process resulting in two distinct adsorption stages, thus achieving a maximum adsorption capacity of 3.752mmolg^-^1 of lead(II). Furthermore, it was found that the regeneration of titanate nanotubes loaded with the lead(II) ions can be readily achieved using the saturated EDTA disodium salt aqueous solution, thereby avoiding the trouble of disposal of adsorbent. The adsorption mechanism was also discussed in detail.

2010-01-01

404

The effects of the focus ion beam milling process on the optical properties of semiconductor nanostructures  

International Nuclear Information System (INIS)

In this work, the effects of the focus ion beam (FIB) milling process on the optical properties of semiconductor nanostructures were investigated. With this aim, a sensitive materials system based on InGaAs/GaAs quantum dots with well known and excellent optical properties was selected for the FIB treatment. The FIB technique was used to locally remove a metallic mask deposited on top of the quantum dot sample. The photoluminescence (PL) signal, collected from the circular openings, was used to infer the possible damage effects of the ion beam on the properties of the dots.

2009-06-24

405

The application of advanced techniques for complex focused-ion-beam device modification  

Energy Technology Data Exchange (ETDEWEB)

Advanced techniques for focused-ion-beam (FIB) device modification have been developed for complex, multistep modifications to circuitry on planar chip technology. Applying gas-assisted etching (GAE) techniques for high-aspect-ratio milling and the selective milling of both conductive and insulating films enhances process latitude. Localized ion-beam-induced deposition of an insulating film provides reconstructive capability in previously modified areas. The application of both techniques for complex device modification on VSLI devices fabricated with CMOS process technology is reviewed. (UK).

1996-12-31

406

Study of the influence of surface carbon on the tribological properties of ion-treated steels  

Energy Technology Data Exchange (ETDEWEB)

Samples of 100Cr6 steel were treated by different ion beams in order to study the evolution of their tribological properties. A strong correlation was found between the amount of surface carbon, whatever its origin (contamination, direct C implantation or ion-beam mixing of a deposited carbon layer), and the reduction of the friction coefficient as well as the improvement of the wear resistance. These results are discussed in the framework of a recent statistical model founded on the asperity concept and describing the tribological behaviour of bilayer systems.

1999-01-02

407

Studies on technology improvement in the production of iodine and bromine  

International Nuclear Information System (INIS)

Results of studies dealing with improvement of the currently employed technology of iodine and bromine production by processing iodine- and bromine-containing borehole effluent water were considered. Potentiality of selective oxidation of iodide-ions in the presence of bromide-ions in acidified borehole effluent water with addition of ozone for initiating oxidation of iodide-ions and iron(2) salt to prevent bromine evolution was confirmed experimentally. Conditions were determined that rule out bromine formation in the solution, but simultaneously permit varying the yield of iodine within 70-100%

2001-07-01

408

Self-organized amorphous material in silicon (0 0 1) by focused ion beam (FIB) system  

Energy Technology Data Exchange (ETDEWEB)

A method using a focused ion beam (FIB) to prepare a silicon amorphous material is presented. The method involves the redeposition of sputtered material generated during the interaction of the Ga{sup +} ion beam with a silicon substrate material. The shape and dimensions of this amorphous material are self-organized and reproducible. The stability of this amorphous material under electron irradiation was investigated in the transmission electron microscopy (TEM). Electron irradiation can induce recrystallization of the amorphous material, resulting in the lateral and vertical growth, starting at an amorphous-crystalline interface, of polysilicon containing defects.

2005-12-15

409

Self-organized amorphous material in silicon (0 0 1) by focused ion beam (FIB) system  

International Nuclear Information System (INIS)

A method using a focused ion beam (FIB) to prepare a silicon amorphous material is presented. The method involves the redeposition of sputtered material generated during the interaction of the Ga"+ ion beam with a silicon substrate material. The shape and dimensions of this amorphous material are self-organized and reproducible. The stability of this amorphous material under electron irradiation was investigated in the transmission electron microscopy (TEM). Electron irradiation can induce recrystallization of the amorphous material, resulting in the lateral and vertical growth, starting at an amorphous-crystalline interface, of polysilicon containing defects.

2005-12-15

410

Reflection of electromagnetic waves by a nonuniform plasma layer covering a metal surface  

International Nuclear Information System (INIS)

Reflection coefficients of electromagnetic waves in a nonuniform plasma layer with electrons, positive ions and negative ions, covering a metal surface are investigated by using the finite-difference-time-domain method. It is shown that the reflection coefficients are influenced greatly by the density gradient on the layer edge, layer thickness and electron proportion, i.e., the effect of the negative ions. It is also found that low reflection or high attenuation can be reached by properly choosing high electron proportion, thick plasma layer, and smooth density gradient in the low frequency regime, but sharp density gradient in the high frequency regime. (authors)

2008-07-01

411

Realization of entirely solid lithium ion batteries; Realisation d`accumulateurs a ions lithium entierement solides  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a prototype of an entirely inorganic lithium ions battery cell. LiCoO{sub 2} thin film cathodes and Li{sub 4/3}Ti{sub 5/3}O{sub 4} thin film anodes have been deposited on Li{sub 3x}La{sub 2/3-x}TiO{sub 3} sintered solid electrolyte pellets and the performances of these battery cells have been tested. (J.S.) 5 refs.

1996-12-31

412

Production of polarized negative ion beams by collisional pumping  

Energy Technology Data Exchange (ETDEWEB)

The production of polarized negative ion beams by collisional pumping is described. Collisional pumping utilizes repeated charge changing collisions in a thick electron-spin-polarized gas or vapor target to form a polarized fast atom beam. The polarized fast atom beam is then partially converted into a polarized negative ion beam in a vapor target. Analysis is presented for a hydrogen beam passing through either a thick polarized H atom target or a thick polarized alkali target. Large polarizations and large currents may be possible.

1983-01-01

413

Production of polarized negative ion beams by ''collisional pumping''  

Energy Technology Data Exchange (ETDEWEB)

The production of polarized negative ion beams by ''collisional pumping'' is described. Collisional pumping utilizes repeated charge changing collisions in a thick electron-spin-polarized gas or vapor target to form a polarized fast atom beam. The polarized fast atom beam is then partially converted into a polarized negative ion beam in a vapor target. Analysis is presented for a hydrogen beam passing through either a thick polarized H atom target or a thick polarized alkali target. Large polarizations and large currents may be possible.

1984-03-01

414

Optogalvanic isotope enrichment of Cu ions in Cu-Ne positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

The isotopic enrichment of copper ions in a positive column Cu-Nu discharge using optogalvanic excitation is analyzed with a rate equation model With excitation at 510.6 nm, the fraction of the ions belonging to the 63-amu isotope of copper is enriched relative to the neutral abundance. Enrichment as large as 10% is calculated when the initial abundance of the neutral isotope is small (< or =0.1) and the discharge current density is large (> or =75 mA/cm/sup 2/). The degree of enrichment is examined as a function of the initial abundance, discharge current, the rate of charge exchange, and the diameter of the discharge tube.

1983-07-01

415

Novel approach towards improving decontamination factor (DF) in treatment of low level radioactive waste  

International Nuclear Information System (INIS)

The use of finely powdered ion exchange resins improve loading of specific ion exchange materials with better performance but as such these materials are not suitable for column operation. However, by proper selection of ion exchange support medium, it is possible to get better product. The radioactive solution can be treated by suspending this material, stirring and allowing to settle. The present method gives DF in the range of 70 - 80 even after repeated use as compared to DF in the range of 5 to 10 by single conventional chemical treatment process. (author)

2001-02-07

416

NMR study of one-dimensional ionic conductor with hollandite-type structure (IV) Rb-priderite  

International Nuclear Information System (INIS)

Conduction properties of Rb"+ ion in Rb-Al-priderite and K"+ ion and Rb"+ ion in (K,Rb)-Al-priderite, were investigated by NMR using "2"7Al in the framework as a probe. Size effect was observed remarkably in the activation energies. Frequency dependence of T_1 in Rb-Al-priderite at a low temperature indicates that the relaxation behavior of "2"7Al in Rb-Al-priderite can be described by the continuum model. Barrier height distributions and 'attempt frequencies' in both samples obtained by a curve-fitting method are discussed in comparison with those of K-Al-priderite. (orig.).

1985-08-18

417

Macro and micro observations on mortar alternation mechanism under the various solution conditions  

Energy Technology Data Exchange (ETDEWEB)

Accelerated aging tests have been conducted to evaluate the long-term durability of cementitious material against aggressive ions. In tests, cementitious specimens were immersed in the solutions containing concentrated aggressive ions at high temperature and it promoted diffusion of the ions in the specimen. This method would be suitable for the evaluation on the aging as the alteration of the specimen would be expected to resemble the natural behavior. This paper presents a classification of alteration mechanism in the immersion tests using MgCl{sub 2} and Na{sub 2}SO{sub 4} solution. This classification was done by relating the changes of compressive strength to microscopic and mineralogical changes.

1995-12-31

418

Ion-plasma nitriding of the alloyed steel using a low pressure arc plasma generator  

International Nuclear Information System (INIS)

A study is made into microhardness and structure of coatings on various system steels (37G2S, 25Kh5M, R6M5), obtained by ion nitriding in a low pressure (10"-"1 Pa) arc discharge plasma. A comparison of properties is accomplished for steels nitrided in an arc gas discharge and in a furnace. It is stated that ion-plasma nitriding in an arc gas plasma generator is an efficient method of alloy steels hardening which allows changing the structure and increasing the hardness of a surface layer up to rather great depth

2006-12-01

419

Improved four-stage accel-decel production of low energy highly stripped heavy ions  

Energy Technology Data Exchange (ETDEWEB)

The two model MP Tandem Van de Graaff accelerators at Brookhaven have been used in a four-stage accel-decel configuration to produce highly stripped low energy heavy ions. The performance in this mode of operation has now been substantially improved by modifications of the second accelerator. The inclined field acceleration tube electrodes at the exit of this accelerator were replaced by straight electrodes, the vacuum was improved and the maximum negative terminal potential was increased. Higher intensity beams of heavier highly stripped ions can now be produced at lower energies than before.

1983-04-01

420

Impact of profile resilience on energy confinement  

International Nuclear Information System (INIS)

Multi-machine experimental observations indicate resilience in the temperature profiles at low pedestal temperatures,whereas at high pedestal temperatures the profile stiffness seems to disappear.The change of the profile behavior impacts the energy confinement,basically due to a strong non-linear dependence of the energy transport on the pedestal temperature together with different critical conditions for the onset of turbulence in the ions and electrons.This possible explanation for the different observations is based on the assumption that both ion and electron energy transport is governed by turbulence which sets in at a critical temperature gradient as well as on a significant energy equipartition between electrons and ions.

421

Excitation of Plasma Fluctuations near ion Giro frequencies during RF Plasma Heating in URAGAN-3M Torsatron  

International Nuclear Information System (INIS)

Currentless plasma in Uragan-3M (U-3M) is produced and heated by absorption of RF power in the region of Alfven waves (AW). The process of plasma heating was explained in (2) as a result of Cherenkov absorption of energy of the fast (EM) and slow (kinetic Alfven) waves by electrons and turbulent ion heating due to excitation of short wave ion Bernstein waves (IBW). In this report we present results of studies of plasma density fluctuations showing existence of a narrow bands near the frequencies of ? ? n?ci (n=1,2,3).

2006-01-01

422

Electron impact ionization of C_6_0 and C_7_0 and decay of the singly and multiply charged (up to z=7) ions produced  

International Nuclear Information System (INIS)

Mass spectrometry was instrumental in the discovery of the fullerenes and the characterization of their special structure (truncated icosahedron). High resolution and high sensitivity mass spectrometry in combination with a crossed molecular beam/electron beam ion source is used here to study a further, very unique property of singly and multiply charged fullerene ions (up to Z=7), i.e. their strong resilience towards decomposition via sequential C_2 evaporation and via Coulomb explosion, respectively. (author).

1994-03-20

423

Electron collisional detachment processes for a 250 keV D/sup -/ ion beam in a partially ionized hydrogen target  

Energy Technology Data Exchange (ETDEWEB)

Neutral atom beams with energies above 200 keV may be required for various purposes in magnetic fusion devices following TFTR, JET and MFTF-B. These beams can be produced much more efficiently by electron detachment from negative ion beams than by electron capture by positive ions. We have investigated the efficiency with which such neutral atoms can be produced by electron detachment in partially ionized hydrogen plasma neutralizers.

1980-09-01

424

Electrochemical reduction of Yttrium ions. Technical report  

Energy Technology Data Exchange (ETDEWEB)

The cathodic electrode process of Y(3+) ions on the Mo electrode in the LICl-KCl molten salt with YCl3(3wt%) in the temperature range of 450 - 530 deg. C has been investigated using cyclic voltammetry and chronopotentiometry. The convolution technique has been applied to the treatment of cyclic voltammogram. The results show that the reduction mechanism of Y(3+) ion is Y(3+) + 3e = Y, a simple one-step process. The cathodic process is very close to a reversible process under lower scanning rates, and is diffusion-controlled. The cathodic product is an insoluble product.

1995-08-01

425

Electro-static beam steering mechanism for a high current negative ion beam consisting of multi-beamlets  

Energy Technology Data Exchange (ETDEWEB)

An electrostatic beam steering mechanism (ESM) has been designed and tested to deflect negative ion beams consisting of multi-beamlets. A steering angle of 10 mrad was obtained within the deviation of less than 1 mrad by biasing two electrodes at 0.5 kV and -0.75 kV for 120 keV H{sup -} ion beam. The current flowing to the positive electrode was no more than 10% of the beam current at a pressure of 2.8x10{sup -5} Torr. (author)

1998-11-01

426

Convoy electron production in polycrystalline and monocrystalline targets  

Energy Technology Data Exchange (ETDEWEB)

The velocity distribution of electrons ejected close to the forward direction by 0.8-2 MeV/A ions traversing various solid targets, including a Au monocrystal, is measured in coincidence with emerging charge-selected ions. The velocity spectrum is observed to be independent of outgoing projectile velocity and charge state for polycrystalline targets. Measurements on the Au crystal under channeling conditions show dependences on final charge state, and are tentatively explained by assuming that the main contribution to the production yield comes from the non-channeled fraction of the ions. A simple model for the creation of the forward-ejected electrons is proposed, which accounts for most of the experimental findings.

1980-01-01

427

Coincidence measurements of M-shell excitation in slow Xe-Xe collisions  

Energy Technology Data Exchange (ETDEWEB)

Ion-photon and ion-Auger-electron coincidence measurements have been performed to study the impact parameter dependence of Xe M-shell excitation in 1.05 MeV Xe/sup 3 +/-Xe collisions. The experimental results are found to be consistent with the prediction of the molecular orbital model of atomic collisions. The average fluorescence yield for the Xe M shell is found to be strongly dependent on the impact parameter. This is ascribed to the production of highly charged Xe ions in close collisions.

1982-07-14

428

Changes in mass density and sound velocity of amorphous Pd{sub 80}Si{sub 20} by low temperature ion irradiation  

Energy Technology Data Exchange (ETDEWEB)

Changes in transverse phonon sound velocity were measured during low temperature irradiation of amorphous Pd{sub 80}Si{sub 20} with 3.5 MeV krypton ions. The sound velocity decreases as a function of the ion fluence and shows a tendency to saturate at large fluences at a relative change of {minus}4.7%. The changes in sound velocity were used to determine the changes in shear elastic constant and in Debye temperature both of which were in reasonable agreement with the value reported in the literature.

1998-12-31

429

A spatial damage energy distribution calculation for ion-implanted materials  

International Nuclear Information System (INIS)

A simple method allowing easy calculation of the spatial damage energy distributions for ion-implanted materials is presented. The direct procedure takes account of the variation with depth of the lateral spreading of implanted ions, as well as the effects of energy transport by the recoiling target atoms. The subsequent computer program LUPIN-3D provides three-dimensional damage distributions and allows the construction of damage energy mappings. Various substrates of technological interest are investigated and several fields of application of the calculation are envisaged. The density of cascades can therefore be determined and heterogeneous amorphization models can be implemented. (orig.).

1989-01-01

430

A new technique for production of yellow cake with double precipitation  

International Nuclear Information System (INIS)

The author presents a new technique for production of yellow cake with double precipitation, thus solving a series of problems for precipitating uranium with traditional double precipitation. The new technique can not only remove ferric ions and sulfate radicals but also make solid-liquid separation easy, utilize effectively the sulfuric acid produced in ferric ions precipitation process, and increase uranium concentration of leaching liquor. To take it as producing yellow cake will save investment, simplify operation, and cut down the consumption of raw materials and energies. It is more competitive than ion-exchange or solvent extraction in the process of extracting-purifying and preparing yellow cake.

1997-01-01

431

A measurement of the cross section for electron impact ionization of Ar"2"+, Kr"2"+ and Xe"2"+  

International Nuclear Information System (INIS)

The crossed electron-ion beams technique was used to measure absolute cross sections for single ionization of Ar"2"+, Kr"2"+ and Xe"2"+ ions at electron energies ranging from threshold to 2000 eV. In contrast to some previous measurements, the metastable contents of the ion beams were small even in the case of Xe"2"+. All measured cross section curves show significant contributions from excitation-autoionization and possibly direct ionization of inner-shell electrons. There is evidence for resonance-excitation-double-autoionization in the case of Xe"2"+. (author).

432

Ultratrace determination in high purity molybdenum and tungsten with ion chromatographic trace-matrix-separation. Pt. 2; Ultra trace analysis using ion chromatography. Ultraspurenanalytik in hochreinem Molybdaen und Wolfram mit ionenchromatographischer Spuren-Matrix-Trennung. Tl. 2; Ionenchromatographische Ultraspurenanalyse  

Energy Technology Data Exchange (ETDEWEB)

The use of high-performance ion exchangers allows a trace-matrix-separation (SMT) directly followed by an ion chromatographic (IC) separation of the analytes. Based on the principles described in Part 1, a combined procedure IC-SMT-IC for metallic impurities in Mo and W is presented. Up to 12 metal traces (Fe, Cu, Pb, Zn, Ni, Co, Cd, Ca, Mn, Sr, Mg and Ba) can be determined in one run with 35 min. A special method for traces of U and Th is also given. Detection limits are typically 10-100 ng g{sup -1} in the metal sample. (author). 14 refs.; 10 figs.; 6 tabs.

1992-01-31

433

The energy dependence of L_#alpha#/L_l X-ray intensity ratio produced by heavy-ion bombardment  

International Nuclear Information System (INIS)

The energy dependence of the Yb and Au L_#alpha#/L_l X-ray intensity ratio, produced by 0.5 - 3.0 MeV/u Li, Be, C, N, F, and Si ion bombardment (Malhi and Gray, Phys. Rev. A 44, 7199, (1991)), measured at 90"0 relative to the beam axis, has been explained. While for light ion impact the behaviour of the alignment parameter as a function of impact velocity is dominant, for the impact of heavier ions the multiple ionization effects become important. Using Larkins' prescription in the last case, calculations have been performed, which agree well with the data over the whole energy range investigated. (Author).

1993-01-01

434

Surface segregation and radiation hardening of 16Cr12MoWSiVNbB steel after irradiation with Ni++ and He+ ions  

British Library Electronic Table of Contents (United Kingdom)

Irradiation of EP-823 (16Cr12MoWsiVNbB) ferritic-martensitic steel with 7-MeV Ni++ ions and with 30- and 70-keV He+ ions at a temperature of 500?C was followed by an increase in the microhardness, which was due to both radiation point defects and changes in the phase composition and the dislocation structure of the steel. It was found that the dependence of the largest relative increase in the microhardness on the concentration of radiation-induced point defects in the near-surface region of the steel under irradiation with different ions correlated with an analogous dependence of the surface segregation of silicon and chromium.

2011-01-01

435

Study on development of multi-composite ceramics  

Energy Technology Data Exchange (ETDEWEB)

Creation of new multi-composite materials is an essential issue to attain an innovative improvement of the current nuclear technology. In this paper, some highlights are focused on the research of creation of those materials and the relating subjects in NIRIM. (1) The KOH corrosion test method are expected to be efficiently available in the limited cases instead of Na corrosion test one. (2) The preliminary creation of the multi-composite ceramics were achieved by Y- ion implantation into sapphire and the RF sputtering, of which the specified orientation was realized by the existence of the buffer layer. The importance of the defect control are described with the relation to the corrosion resistance improvement. (3) The ion beam induced phenomena have been investigated on the surface change of silica glass and the crystallization of Cu film on SrTiO{sub 3}. (4) The electronic states of the alkali-metal adsorbed surfaces and that of the ...

1996-03-01

437

Structure and properties of Li2Zn2(MoO4)3 crystals activated with copper and chromium ions  

British Library Electronic Table of Contents (United Kingdom)

Based on the corrected phase diagrams proper growth conditions for Li2Zn2(MoO4)3 crystals are selected. Large crystals (up to 100 mm), both impurity-free and activated by transition metal ions (Cu, Cr), are grown by the low-gradient Czochralski method. By the EPR method the charge state and structural position of copper and chromium ions are determined. The performed studies of luminescent properties show that for impurity-free crystals luminescence with ? = 388 nm with a two-exponential luminescence decay with ?1 = 2 ns and ?2 = 6 ns is observed at room temperature. At 77 K for both impurity-free crystals and those activated with transition metal ions luminescence with ? = 560 nm and the luminescence lifetime ? = 100 ns is observed, the intensity of luminescence with ? = 560 nm depending ...

2011-01-01

438

Spectrophotometric determination of aluminium ion in drinking water by flow infection analysis  

International Nuclear Information System (INIS)

Optimum analytical conditions of the aluminium ion were established by flow injection analysis. Eriochrome Cyanine R(ECR) dye reacts with the aluminium ion at pH 6.0 form a complex that exhibits maximum absorption at 535 nm. Reaction condition including the mixing and the reaction coil length, the concentration and the pH of the buffer solution, temperature, and injection loop volume were optimized to introduce this reaction into flow injection analysis. The results were as follows. A mixing coil length of 0.5 m and a reaction coil length of 4.0 m, the pH 6.0 and 1M of acetate buffer solution, the ECR concentration of 0.56 mM, the reaction temperature of 40 .deg. C, the injection loop volume of 300 #mu#L were chosen as optimum conditions. Under these conditions the detection limit of the aluminium ion was less than 0.05 mg/L and the repeatability was better than 1%. A sampling frequency of 24 times for an hour was achieved. ...

2000-10-01

440

Simultaneous Formation of Surface Ripples and Metallic Nanodots Induced by Phase Decomposition and Focused Ion Beam Patterning  

Energy Technology Data Exchange (ETDEWEB)

We report the simultaneous formation of self-assembled surface ripples in Cd{sub 2}Nb{sub 2}O{sub 7} pyrochlore caused by focused ion beam (FIB) patterning and uniformly distributed metallic nanodots induced by phase decomposition under ion bombardment. The characteristic wavelength of the surface ripples is controllable from the nm to the sub-{micro}m scale. High-density Cd metallic nanoparticles, {approx} 5 nm, formed and the distribution of nanoparticles is consistent with the morphological characteristics of the ripple pattern. This approach provides a means of fabricating surface nanostructure with various patterns and a controllable particle size and distribution by combining ion beam-induced phase decomposition with high-precision FIB patterning.

2006-02-01

441

Silund Nanosecond High-Current Linear Induction Accelerator ...  

Science.gov (United States)

... the high current induction linear accelerator of the nanosecond range, meant to be used as injector in the collective ion accelerator, are presented. ...

1972-07-13

442

SSRM characterisation of FIB induced damage in silicon  

International Nuclear Information System (INIS)

Scanning spreading resistance microscopy (SSRM) has been applied to study focused ion beam (FIB) induced damage in silicon in dependence on ion irradiation doses from 10"1"2 cm"-"2 to 2#centre dot#10"1"6 cm"-"2. Starting from the lowest dose, SSRM detects increasing spreading resistance (SR) with increasing dose. For doses from 2#centre dot#10"1"3 cm"-"2 to 4#centre dot#10"1"4 cm"-"2, a slight decrease of SR is measured whereas for higher doses SR again slightly increases. The results are explained by physical effects like decreased carrier mobility due to increased scattering, amorphisation of silicon and precipitation of implanted Ga ions. The results clearly prove that SSRM is well suited for the fast detection of ion beam induced damage with high lateral resolution.

2008-03-01

443

SAXS studies on added-salt species dependence of conformation of fully-charged poly(L-glutamate) in aqueous solutions  

Energy Technology Data Exchange (ETDEWEB)

The effect of counter-ion species on the local conformation of fully-charged poly(L-glutamate) in added-salt aqueous solutions were studied by small-angle X-ray scattering(SAXS). In the case of presence of monovalent counter-ion, the scattering behaviour could be explained by taking into consideration the excluded volume effect and intermolecular-interface interaction on the scattering function of wormlike chain. On the other hand, since SAXS profile of the solution in the presence of divalent counter-ion well fitted to the scattering function of dendrimer, it suggested that the conformation of polymer chain in such solution would be more compact conformation than that of presence of monovalent ion.

2010-10-01

446

Research on Actinides in Nuclear Fuel Cycles  

International Nuclear Information System (INIS)

The electrochemical/spectroscopic integrated measurement system was designed and set up for spectro-electrochemical measurements of lanthanide and actinide ions in high temperature molten salt media. A compact electrochemical cell and electrode system was also developed for the minimization of reactants, and consequently minimization of radioactive waste generation. By applying these equipment, oxidation and reduction behavior of lanthanide and actinide ions in molten salt media have been made. Also, thermodynamic parameter values are determined by interpreting the results obtained from electrochemical measurements. Several lanthanide ions exhibited fluorescence properties in molten salt. Also, UV-VIS measurement provided the detailed information regarding the oxidation states of lanthanide and actinide ions in high temperature molten salt media

2007-04-01

447

Refilling Intracellular Calcium Stores  

UK PubMed Central (United Kingdom)

Within the cardiac cell, the movements of calcium ions are tightly regulated by a number of regulatory proteins including pumps, and channels. The sarcoplasmic reticulum (SR) is in large part...Full Text Available

2010-01-01

448

Quantum coherence in ion channels: resonances, transport and verification  

Energy Technology Data Exchange (ETDEWEB)

Recently it was demonstrated that long-lived quantum coherence exists during excitation energy transport in photosynthesis. It is a valid question up to which length, time and mass scales quantum coherence may extend, how one may detect this coherence and what, if any, role it plays in the dynamics of the system. Here we suggest that the selectivity filter of ion channels may exhibit quantum coherence, which might be relevant for the process of ion selectivity and conduction. We show that quantum resonances could provide an alternative approach to ultrafast two-dimensional (2D) spectroscopy to probe these quantum coherences. We demonstrate that the emergence of resonances in the conduction of ion channels that are modulated periodically by time-dependent external electric fields can serve as signatures of quantum coherence in such a system. Assessments of experimental feasibility and specific paths towards the experimental ...

2010-08-15

449

Production of high-q ions by laser bombardment method  

International Nuclear Information System (INIS)

The expanding plasma produced when an intense pulse of laser radiation is focused in vacuum onto a solid target has been used as a source of highly stripped ions for collision cross-section measurements. Usable fluxes of carbon nuclei at energies of a few hundred eV/charge have been obtained by irradiation of graphite with pulses of CO"2 laser radiation at a focused power density of 3 x 10_1_0 W/cm_2. Bombardment of aluminum and iron targets at comparable power levels have yielded ions of maximum charges of 9 and 16 respectively. A time-of-flight apparatus has been constructed to utilize the laser source for measurement of electron capture cross sections for highly stripped ions in gases at energies in the few hundred eV/charge range. Apertures collimate an ion beam from the plasma blowoff, and an electrostatic analyzer selects ions from the expanding plasma which have the same ...

1981-01-01

450

Precise lithium isotopic analysis by thermal ionization mass spectrometry using lithium phosphate as an ion source material  

International Nuclear Information System (INIS)

A high-precision Li isotope analysis was developed for determining the Li"+ ion emitted from lithium phosphate as an ion source material by a Re double-filament ionization method in the thermal ionization mass spectrometry. In this method, Li isotopic fractionation is distinctly less sensitive to the filament temperature than those in the previous methods, and stable and high ion beam intensity of more than 8 x 10"-"1"1 A for "7Li is obtained. These advantages in determining the "7Li/"6Li ratio result in the analytical reproducibility of 0.26 per mille (1#sigma#). Furthermore, the sample preparation is simple and the low temperature (850degC) required by this method ensures the analysis of the isotopic composition of small amounts of Li with less influence of Li contamination to the sample, compared with the previous methods. (author).

452

Phospholemman: A Novel Cardiac Stress Protein  

UK PubMed Central (United Kingdom)

Phospholemman (PLM), a member of the FXYD family of regulators of ion transport, is a major sarcolemmal substrate for protein kinases A and C in cardiac and skeletal muscle. In the heart, PLM...Full Text Available

2010-08-01

453

PHOTON-HADRON INTERACTIONS AT RHIC AND LHC ENERGIES.  

Energy Technology Data Exchange (ETDEWEB)

Heavy Ion Collisions at RHIC and LHC energies are potentially an interesting laboratory for the study of QED. In these collisions, a Heavy Ion in one beam sees a highly Lorentz contracted electric field due to an oncoming beam particle. The Electric field reaches a maximum value of E {approx_equal} {gamma}{sub eff} {center_dot} Z {center_dot} e/b{sup 2}, where the apparent Lorentz factor, {gamma}{sub eff} = 2 {center_dot} {gamma}{sub beam}{sup 2} - 1. The collision may be viewed in terms of a flux of photons colliding with a stationary ion target using the equivalent photon approximation, originally introduced by Fermi in 1924. We show that the cross section for Inelastic Electromagnetic Interactions of Heavy Ions are both calculable and have been measured in the first RHIC running period.

2002-03-01

454

Optical and Structural Characteristics of Heavily Boron ...  

Science.gov (United States)

... Abstract : Cadmium telluride single crystals were subjected to multiple-energy boron ion implants with total doses up to 1.5 x 10 sq cm. ...

1988-05-24

455

Neutron time-of-flight spectroscopy and the reaction "8"8Sr("3He,n)"9"0Zr  

International Nuclear Information System (INIS)

... states helium 3 reactions ion sources mev range 10-100 neutron spectrometers

456

Mobilities of CO_2"+ and N_2O"+ in He, Ar and N_2 gases  

International Nuclear Information System (INIS)

... argon carbon dioxide cations electric fields gases helium ion mobility molecular

1976-01-01

457

Milliampere class Si{sup -} or B{sup -} negative ion extraction from RF plasma sputter type heavy negative ion source  

Energy Technology Data Exchange (ETDEWEB)

An RF plasma sputter type heavy negative ion source, which can deliver mA-class negative ion beams (12.1 mA, 1.6 mA and 2.3 mA for Cu{sup -}, C{sup -} and C{sub 2}{sup -} currents, respectively) in dc-mode operation, has been developed. In ion source, a dense plasma of 10{sup 11} cm{sup -3} order was generated in the xenon gas pressure of 10{sup -3}-10{sup -2} Pa with an rf (13.56 MHz) power of 200 - 300 W by using an RF coil, and a relatively large sputtering target of 42 mm in diameter was used. As for intense negative ion beams of silicon or boron which are important dopants for semiconductor fabrication, negative ion extraction properties of the negative ion source was investigated. The extracted total negative ion currents of 4.4 mA for a silicon target and 2.8 mA for a LaB{sub 6} target were obtained after electrons were eliminated by ...

1993-12-31

458

L. V. BALDWIN &TAL BY  

Science.gov (United States)

L. V. BALDWIN &TAL. APPARATUS FOR INCREASING ION ENGINE BEAM DENSITY. Filed Jan. 4, 1963 ... Lionel V. Baldwin. Fort Collins. Colo.. and Vid A. ...

459

Kinetics of uranium (VI) ions adsorption on activated charcoal from aqueous solutions  

Energy Technology Data Exchange (ETDEWEB)

The temperature and concentration dependence of the kinetics of uranium(VI) ions adsorption onto activated charcoal from aqueous solutions has been studied. The adsorption proceeds via a rather fast stage followed by a slower one, with activation energies of 5.41 and 17.46 kJ . mol[sup -1] respectively. The diffusion of uranium ions into the pores of the activated charcoal controls the kinetics of adsorption which follows the Langmuir isotherm equation in the concentration range studied. The adsorption equilibrium constant k[sub c] has been derived at temperatures between 283 K and 323 K as well as [Delta] G, [Delta] H and [Delta] S. The results indicate that the adsorption of uranium ions on activated charcoal is an endothermic process. (orig.)

1994-01-01

460

Ion-radiation hardening of magnesium oxide crystals  

International Nuclear Information System (INIS)

Consideration is given to the data, demonstrating the effect of ion radiation on strength characteristics of ionic crystals, presented by magnesium oxide. Crystals, prepared in the form of plates, were irradiated by Si"+, Fe"+, C"+ ions by the dose of 10"1"6-10"1"7 ion/cm"2 at room temperature in vacuum. The following characteristics were investigated: dislocation density, microhardness, crack resistance. Investigation of dislocation structure showed, that dislocation density in irradiated sample was 2-3 times higher, as compared to nonirradiated one. Sufficient increase of fracture viscosity of MgO crystals was revealed. It can be conditioned by occurrence of compression stresses in the surface layer, decelerating crack formation and propagation.

461

Ion channels, transporters, and pumps as targets for heart failure  

UK PubMed Central (United Kingdom)

Congestive heart failure (CHF) is a leading cause of morbidity and mortality. CHF is marked by atrial and ventricular enlargement and reduced cardiac contractility, as well as an association...Full Text Available

2009-10-01

462

Ion beam induced charge imaging of epitaxial GaN detectors  

Energy Technology Data Exchange (ETDEWEB)

We report the use of ion beam induced charge imaging to characterise the charge signal uniformity of epitaxial gallium nitride radiation detectors. The detectors were fabricated from 2 {mu}m thick semi-insulating gallium nitride, grown by MOCVD on a sapphire substrate. A carrier concentration of 1.4x10{sup 15} cm{sup -3} was measured using capacitance-voltage measurements. Ion beam induced charge imaging was carried out with a 2 MeV alpha particle beam focussed to a 3 {mu}m diameter and raster scanned across the device. The resulting ion beam images show excellent charge signal uniformity in this material with no evidence of material defects or polycrystalline structure on the micrometer length scale. No evidence of charge signal trapping was observed in these devices.

2004-09-21

465

Identification of Metal Ion Chloro Complexes in an Ambient ...  

Science.gov (United States)

... a given ternary molten salt system under conditions which are greatly " different than the normal method of potentiometric titration, that is, high ...

1985-05-25

466

High dielectric constant ceramics for ion-electron sources  

Energy Technology Data Exchange (ETDEWEB)

Ferroelectric disks, coated with proper electrodes, can easily produce a dense plasma cloud when excited with a high-voltage pulse. This plasma can be a source of either electrons or ions depending on the sign of the extracting field set in front of the disk. We present the behavior of the disks operating at high frequency as emitters of both electrons and ions in two experimental configurations: (a) without and (b) with two screening grids. These two screening grids are inserted when the plasma must be confined within the cathode region. The system is capable of providing ion pulses of a few hundred milliamperes, whose length can range from a hundred nanoseconds to dozen microseconds. The electron pulses of energetic electrons have typically an amplitude higher than a couple of amperes. Tests at MHz repetition rate were positive as for stable operation.

2002-08-21

468

Growth mechanisms and thermal stability of ion-beam-induced epitaxial Pd/sub 2/Si films  

Energy Technology Data Exchange (ETDEWEB)

Growth mechanisms and thermal stability of ion-beam-induced epitaxial Pd/sub 2/Si films are investigated using Rutherford backscattering and channelling techniques. Epitaxial growth of Pd/sub 2/Si films was observed at room temperature by argon ion implantation into as-deposited Pd/Si(111) structures and furnace-annealed Pd/sub 2/Si(polycrystalline)/Pd/sub 2/Si(epitaxial)/Si(111) structures. Some additional experiments to check the growth mechanisms are also presented, in which the implantation energies, substrate orientations and dose rates were changed. Finally, the stability of the ion-beam-induced epitaxial Pd/sub 2/Si films on subsequent furnace annealing is studied.

1982-06-11

469

Growth meachnisms and thermal stability of ion-beam-induced epitaxial Pd/sub 2/Si films  

Energy Technology Data Exchange (ETDEWEB)

Growth mechanisms and thermal stability of ion-beam-induced epitaxial Pd/sub 2/Si films are investigated using Rutherford backscattering and channelling techniques. Epitaxial growth of Pd/sub 2/Si films was observed at room temperature by argon ion implantation into as-deposited Pd/Si(111) structures and furnace-annealed Pd/sub 2/Si(polycrystalline)/Pd/sub 2/Si(epitaxial)/Si(111) structures. Some additional experiments to check the growth mechanisms are also presented, in which the implantation energies, substrate orientations and dose rates were changed. Finally, the stability of the ion-beam-induced epitaxial Pd/sub 2/Si films on subsequent furnace annealing is studied.

1982-06-11

470

Fundamentals of focused ion beam nanostructural processing: below,at and above the surface  

Energy Technology Data Exchange (ETDEWEB)

This article considers the fundamentals of what happens in asolid when it is impacted with a medium energy gallium ion. The study ofthe ion/sample interaction at the nanometer scale is applicable to mostfocused ion beam (FIB) based work even if the FIB/sample interaction isonly a step in the process, e.g., micromachining or microelectronicdevice processing. Whereas the objective in other articles in this issueis to use the FIB tool to characterize a material or to machine a deviceor transmission electron microscopy (TEM) sample, the goal of the FIB inthis article is to have the FIB/sample interaction itself become theproduct. To that end, the FIB/sample interaction is considered in threecategories according to geometry: below, at, and above the surface.First, the FIB ions can penetrate the top atom layer(s) and interactbelow the surface. Ion implantation and ion ...

2007-03-30

471

Focused ion beam sculpting curved shapes.  

Energy Technology Data Exchange (ETDEWEB)

A focused ion beam (FIB) is used to accurately sculpt predetermined micron-scale, curved shapes in a number of solids. Using a digitally scanned ion beam system, various features are sputtered including hemispheres and sine waves having dimensions from 1-50 {micro}m. Ion sculpting is accomplished by changing pixel dwell time within individual boustrophedonic scans. The pixel dwell times used to sculpt a given shape are determined prior to milling and account for the material-specific, angle-dependent sputter yield, Y({theta}), as well as the amount of beam overlap in adjacent pixels. A number of target materials, including C, Au and Si, are accurately sculpted using this method. For several target materials, the curved feature shape closely matches the intended shape with milled feature depths within 5% of intended values.

2005-02-01

472

Focused ion beam preparation of inclined planes in semiconductor materials  

International Nuclear Information System (INIS)

Focused ion beam (FIB) micromachining has been used to produce inclined planes on semiconductor surfaces. A 10 keV FIB system, utilising a Ga"+ liquid metal ion source (LMIS), was employed. The ramped surfaces were prepared by digitally deflecting the ion beam in a serpentine fashion over a rectangular area and incrementing the time the beam spends at a pixel, dwell time, line by line. For the conditions used, control in micromachining the inclination of the ramps to the starting horizontal surface is of the order of 1 arc s per scan of the FIB over the area of interest. The possibility of using such surfaces prepared by FIB, along with vacuum growth techniques such as molecular beam epitaxy (MBE), for application to strain relief structures and lateral device production is discussed. (author).

473

Focused Ion Beam Induced Effects on MOS Transistor Parameters  

Energy Technology Data Exchange (ETDEWEB)

We report on recent studies of the effects of 50 keV focused ion beam (FIB) exposure on MOS transistors. We demonstrate that the changes in value of transistor parameters (such as threshold voltage, V{sub t}) are essentially the same for exposure to a Ga+ ion beam at 30 and 50 keV under the same exposure conditions. We characterize the effects of FIB exposure on test transistors fabricated in both 0.5 {micro}m and 0.225 {micro}m technologies from two different vendors. We report on the effectiveness of overlying metal layers in screening MOS transistors from FIB-induced damage and examine the importance of ion dose rate and the physical dimensions of the exposed area.

1999-07-28

474

Facile synthesis and the sensitized luminescence of europium ions-doped titanate nanowires  

International Nuclear Information System (INIS)

Europium (Eu) ions-doped titanate nanowires were synthesized via a sol-gel-hydrothermal chemistry and they were found to be roll multilayered trititanate-type nanowires intercalated with Eu3+ and alkali ions. The average diameter was about 20 nm for nanowires synthesized in NaOH solution and about 10 nm for nanowires synthesized in KOH solution. Under ultraviolet excitation the nanowires showed bright red emission corresponding to 5D0-7Fj of Eu3+ ions at room temperature, which was attributed to the non-radiative energy transfer from the surrounding Ti-O octahedral nanosheets to the central Eu3+ ions in interlayer. The luminescent properties of nanowires were influenced by the type of co-intercalated alkali ions, doping degree, hydrothermal and annealing temperatures. The intensity ratio of 5D0-7F2 to 5D0-7F1 of titanate nanowires intercalated with Eu3+ and Na+ ...

2009-04-15

475

Fabrication of nanoelectrodes for neurophysiology: cathodic electrophoretic paint insulation and focused ion beam milling  

UK PubMed Central (United Kingdom)

The fabrication and characterization of tungsten nanoelectrodes insulated with cathodic electrophoretic paint is described together with their application within the field of neurophysiology....Full Text Available

2005-09-01

477

England AFB, Alexandria, Louisiana. Revised Uniform ...  

Science.gov (United States)

... IONS ENGLAND AF8 LOUISIANA/ALEXANDRIA WBAN # 13934 17 ... 33 88 89 ft 244 3 Egland AFB, Alexandria La. AFE ...

1972-05-25

478

Electrospun porous SnO2 nanotubes as high capacity anode materials for lithium ion batteries  

British Library Electronic Table of Contents (United Kingdom)

Porous SnO2 nanotubes were prepared via electrospinning followed by calcination in air. As anode materials for lithium ion batteries, the porous nanotubes delivered a high discharge capacity of 807mAhg^-^1 after 50cycles. Even after cycled at high rates, the electrode still retained a high fraction of its theoretical capacity. Such excellent performances of porous SnO2 nanotubes could be attributed to the porous and hollow structure which facilitated liquid electrolyte diffusion into the bulk materials and buffered large volume changes during lithium ions insertion/extraction. Furthermore, the nanoparticles of nanotubes provided the shorter diffusion length for lithium ions insertion which benefited in retaining the structural stability and good rate performance. Our results demonstrated t...

2010-01-01

479

Electron Capture Dissociation Implementation Progress in Fourier Transform Ion Cyclotron Resonance Mass Spectrometry  

British Library Electronic Table of Contents (United Kingdom)

Successful electron capture dissociation (ECD) Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) applications to peptide and protein structural analysis have been enabled by constant progress in implementation of improved electron injection techniques. The rate of ECD product ion formation has been increased to match the liquid chromatography and capillary electrophoresis timescales, and ECD has been combined with infrared multiphoton dissociation in a single experimental configuration to provide simultaneous irradiation, fast switching between the two techniques, and good spatial overlap between ion, photon, and electron beams. Here we begin by describing advantages and disadvantages of the various existing electron injection techniques for ECD in FT-ICR MS. We next ...

2008-01-01

480

Electrical properties of focused-ion-beam boron-implanted silicon  

International Nuclear Information System (INIS)

Electrical properties of 16 keV, focused-ion-beam (FIB) (beam diameter: 1 #mu#m, current density: 50 mA/cm"2) boron-implanted silicon layers have been investigated as a function of beam scan speed and ion dose, and compared with those obtained by conventional implantation (current density: 0.4 #mu#A/cm"2). High electrical activation of the FIB implanted layers is obtained by annealing below 800"0C as a result of the increase in amorphous zones created in the implanted layers. Amorphous zone overlapping is assumed to occur at FIB implantation doses of 3 - 4 x 10"1"5 ions/cm"2 from the results of electrical activation and the carrier profile of implanted regions annealed at low temperature, if beam scan speed is lowered to about 10"-"2 cm/s. (author).

481

Effects on focused ion beam irradiation on MOS transistors  

Energy Technology Data Exchange (ETDEWEB)

The effects of irradiation from a focused ion beam (FIB) system on MOS transistors are reported systematically for the first time. Three MOS transistor technologies, with 0.5, 1, and 3 {mu}m minimum feature sizes and with gate oxide thicknesses ranging from 11 to 50 nm, were analyzed. Significant shifts in transistor parameters (such as threshold voltage, transconductance, and mobility) were observed following irradiation with a 30 keV Ga{sup +} focused ion beam with ion doses varying by over 5 orders of magnitude. The apparent damage mechanism (which involved the creation of interface traps, oxide trapped charge, or both) and extent of damage were different for each of the three technologies investigated.

1997-04-01

482

Development of ambient sampling chemi/chemical ion source with dielectric barrier discharge  

British Library Electronic Table of Contents (United Kingdom)

The development of a new configuration of chemical ionization (CI)-based ion source is presented. The ambient air containing the gaseous sample is sniffed into an enclosed ionization chamber which is of sub-ambient pressure, and is subsequently mixed with metastable species in front of the ion inlet of the mass spectrometer. Metastable helium atoms (He*) are used in this study as the primary ionizing agents and are generated from a dielectric barrier discharge (DBD) source. The DBD is powered by an AC high-voltage supply and the configuration of the electrodes is in such a way that the generated plasma is confined within the discharge tube and is not extended into the ionization chamber. The construction of the ion source is simple, and volatile compounds released from the bulky sample can...

2010-01-01

483

Crystal Chemistry of Ceramic/Mineral Systems  

Science.gov (United States)

... 1. Reeber, RR, Kusy, RP, Yu, N. and Chu, WK " Formation of a Solid Lubricant in Boron Carbide by Nitrogen Ion Implantation and Laser Annealing ...

1992-12-08

484

Controlled manipulation of carbon nanopillars and cantilevers by focused ion beam  

International Nuclear Information System (INIS)

We explore a novel phenomenon of focused ion beam (FIB) induced bending of carbon nanopillars or cantilever structures. The bending occurs towards the ion beam during scanning. The explanation of this bending has been sought on the basis of a model which considers temperature rise and gradients caused by the impinging ion beam. The process is controllable and reversible, which makes it highly suitable for in situ manipulation to make desired 3D shapes by the piecewise bending of the nanopillars and cantilever structures during their fabrication using electron beam or FIB chemical vapor deposition (EB-CVD or FIB-CVD). Its usefulness in the fabrication of nanosize mechanical components has been demonstrated by making a branch structure from a single cantilever.

2008-05-21

485

Channeling studies of radiation damage in metal-silicides  

Science.gov (United States)

Channeling effect measurements have been employed to investigate radiation damage produced by 100-keV Ar ions in preferred oriented polycrystalline metal-silicide layers, such as Pd/sub 2/Si and NiSi/sub 2/ layers formed on single-crystalline Si. For room-temperature implantation, an amount of the damage in Pd/sub 2/Si layers was found to saturate at doses between 3 x 10/sup 14/ and 1 x 10/sup 17/ ions/cm/sup 2/, where the minimum aligned yield of 1.5-MeV He ions was nearly 40% of the random one. On the contrary, it was observed that the NiSi/sub 2/ layers became amorphous at doses higher than 3 x 10/sup 15/ ions/cm/sup 2/. These results were confirmed by the reflection electron diffraction analyses.

1978-01-01

486

Channeling studies of radiation damage in metal-silicides  

International Nuclear Information System (INIS)

Channeling effect measurements have been employed to investigate radiation damage produced by 100-keV Ar ions in preferred oriented polycrystalline metal-silicide layers, such as Pd_2Si and NiSi_2 layers formed on single-crystalline Si. For room-temperature implantation, an amount of the damage in Pd_2Si layers was found to saturate at doses between 3 x 10"1"4 and 1 x 10"1"7 ions/cm"2, where the minimum aligned yield of 1.5-MeV He ions was nearly 40% of the random one. On the contrary, it was observed that the NiSi_2 layers became amorphous at doses higher than 3 x 10"1"5 ions/cm"2. These results were confirmed by the reflection electron diffraction analyses.

487

Cardiac Channelopathies and Sudden Infant Death Syndrome  

British Library Electronic Table of Contents (United Kingdom)

Abstract Sudden infant death syndrome (SIDS) is always a devastating and unexpected occurrence. SIDS is the leading cause of death in the first 6 months after birth in the industrialized world. Since the discovery in 1998 of long QT syndrome as an underlying substrate for SIDS, around 10-20% of SIDS cases have been proposed as being caused by genetic variants in either ion channel or ion channel-associated proteins. Until now, 10 cardiac channelopathy susceptibility genes have been found to be implicated in the pathogenesis of SIDS. Four of the genes encode cardiac ion channel a-subunits, 3 genes encode ion channel b-subunits, and 3 genes encode other channel-interacting proteins. All 10 genes have been associated with primary electrical heart diseases. SIDS may hereby be the initial sympt...

2011-01-01

488

Beam emittance measurements of ORNL negative ion sources  

Energy Technology Data Exchange (ETDEWEB)

The emittances of hydrogen and deuterium negative ion beams produced by volume ion sources have been measured in a transverse plane normal to the beam trajectory. The extraction voltage was varied from 10 to 40 kV, and the transverse magnetic field in the Penning discharges was varied from 0.1 to 0.2 T. Measurements were made on beams with current densities up to 60 mA/cm/sup 2/ at Oak Ridge National Laboratory with an emittance scanner originally developed at Los Alamos National Laboratory. The beam profile at the scanner can be used to improve the accuracy of the emittance measurements. Other factors affecting emittance measurements are discussed. This analysis may be applicable to other ion sources. 6 figs.

1989-01-01

490

Absorption of lead from the bronchial region of the lung  

International Nuclear Information System (INIS)

Experiments have been reported previously in which lead-212 ions with lead carrier were instilled into the lungs of anaesthetised rabbits. Experiments were also reported in which bismuth-207 chloride was instilled into rabbit lung. To check that the chloride compound was cleared in the same way as ions instilled in isolation, lead-203 chloride has been instilled in three rabbits. Measurements of absorption of ionic lead have been repeated using the radon-222 daughter, lead-214. Rates of clearance from the lung of "2"0"3Pb as the chloride and "2"1"2Pb ions are compared, and retention functions are derived. Clearance from the lung of "2"1"4Pb ions is also shown, and retention functions are derived. (U.K.).

1978-03-01

492

2,3-dihydroxybenzoic acid amides of tetraazaalkanes and tetraaza cycloalkanes  

Energy Technology Data Exchange (ETDEWEB)

The present compounds are useful as specific sequestering agents for actinide (IV) ions. Also described is a method for the 2,3-dihydroxybenzamidation of azaalkanes.

1980-01-01

493

(Evaluation of the high intensity plasma sputer negative ion source and to test the response of the University of Tsukuba 13-MV tandem accelerator to mA intensity level pulsed mode heavy negative ion beams)  

Energy Technology Data Exchange (ETDEWEB)

A working visit was made to the National Laboratory for High Energy Physics, Tsukuba, Japan, during the time periods May 16, 1988--June 15, 1988 for the purposes of further evaluation of the high intensity plasma sputter negative ion source and to test the response of the University of Tsukuba 13-MV tandem accelerator to mA intensity level pulsed mode heavy negative ion beams. During the visit, the traveler worked in collaboration with Japanese scientists in installing and testing of the source on the University of Tsukuba tandem electrostatic accelerator injector. During the course of preliminary testing of the ion source and prior to actual injection into the accelerator, sparking began in one or more tube sections, which ultimately led to the decision to replace the damaged tube sections. This problem led to postponement of the scheduled tandem accelerator tests. The traveler attended the Seventh International Conference ...

1988-07-06

494

Triple ion-beam studies of radiation damage effects in a 316LN austenitic alloy for a high power spallation neutron source  

Energy Technology Data Exchange (ETDEWEB)

Austenitic 316LN alloy was ion-irradiated using the unique Triple Ion Beam Facility (TIF) at ORNL to investigate radiation damage effects relevant to spallation neutron sources. The TIF was used to simulate significant features of GeV proton irradiation effects in spallation neutron source target materials by producing displacement damage while simultaneously injecting helium and hydrogen at appropriately high gas/dpa ratios. Irradiations were carried out at 80, 200, and 350 C using 3.5 MeV Fe{sup ++}, 360 keV He{sup +}, and 180 keV H{sup +} to accumulate 50 dpa by Fe, 10,000 appm of He, and 50,000 appm of H. Irradiations were also carried out at 200 C in single and dual ion beam modes. The specific ion energies were chosen to maximize the damage and the gas accumulation at a depth of {approximately} 1 {micro}m. Variations in microstructure and hardness of irradiated specimens were studied using ...

1997-09-01

495

Report of the Government Industrial Research Institute, Osaka, No. 388, February 1993. High lithium ion conductive solid electrolytes  

Energy Technology Data Exchange (ETDEWEB)

Research investigating applicability of lithium salts for solid electrolyte batteries was described. The studies included determinations of lithium ion conductivities in solid electrolyte systems based on Li4SiO4, LiTi2(PO4)3, and ceramic materials. Research on all solid state lithium cells utilizing TiS2 NiPS3 electrodes was also reported.

1993-01-01

496

Microstructural evolution of single crystalline Al_2O_3 irradiated with single and triple ion beams  

International Nuclear Information System (INIS)

The radiation-induced microstructural changes have been studied by cross-sectional transmission electron microscopy for single-crystal #alpha#-Al_2O_3 samples irradiated with triple ion beams (0.25 MeV H"+, 0.6 MeV He"+ and 2.4 MeV O"2"+; 'Triple (A)'), (0.33 MeV H"+, 0.45 MeV He"+ and 1.3 MeV O"+; 'Triple (B)') and three consecutive single ion beams (0.3 MeV H"+ ion followed by 0.6 MeV He"+ and then 0.8 MeV O"+ ions) at 650 C to doses in the range 0.1-8.4 dpa at the damage peak. In the specimen irradiated with Triple (A), having the same average projected range to a total peak dose of 3.7 dpa, cavities with an average diameter of 13 nm were formed between 1.2 and 1.75 #mu#m in depth causing a swelling of 0.1% at the peak, which is larger than those of the specimens irradiated with other conditions. The extent of the cavity-introduced region is some 40% smaller than observed in the damage region due to ...

497

Extension of improved particle and energy confinement regime in the core of LHD plasma  

International Nuclear Information System (INIS)

Recent two major topics of Large Helical Device (LHD) towards fusion relevant conditions, high-density operation and high-ion-temperature operation, are reported. Super dense core plasma was obtained by the combination of repetitive hydrogen ice pellet injection and high power neutral beam injection (NBI) heating. A very peaked density profile with the highest central density of 1.1x1021 m-3 was produced showing that the particle transport was suppressed very well in the plasma core. The spatial density varies as the position of magnetic axis (Rax), and the steepest profile is obtained at Rax=3.95 m. The highest central ion temperature of 5.6 keV was obtained in hydrogen plasma at electron density of 1.6 x 1019 m-3 by NBI, where a peaked ion-temperature profile with internal ion energy transport barrier was observed. The profile of electron temperature did not change much and was broad even when the ...

2009-06-01

498

A precise structure redetermination of nickel ammonium sulfate hexahydrate, Ni(H_2O)_6.2NH_4.2SO_4  

International Nuclear Information System (INIS)

The Ni(H_2O)_6 ion is located at an inversion center. Six octahedral water molecules surround the Ni"I"I ion and form hydrogen bonds with the sulfate groups. Each ammonium group binds to the sulfate groups through hydrogen bonds. (orig.).

1994-05-01