Design: voice activated door opener.
A voice activated garage door opener was designed for a handicapped person to open a garage door without assistance. This design uses speech recognition of one word. The activating word that was chosen is "up". The frequency spectrum of "up" was captured on a soundboard and is the basis of this design. Filters are used to pick out three frequency bands in this spectrum. The output signals from these filters are then compared to three threshold voltages using voltage comparators. If the output signals from the filters are above the threshold voltages, the comparators go high. Monostable multivibrators are used on the output of the comparators to lengthen the high pulses. When all of the pulses from the monostable multivibrators are high at the same time, an AND gate output goes high. This high pulse activates the door opener. PMID:8329601
1993-01-01
Energy Technology Data Exchange (ETDEWEB)
The ventilation requirements for decontamination are normally determined with a static calculation method. In some cases, the pollutant emission is intermittent, for example in the car park of an office building, where all the cars enter and leave the place nearly at the same time. Generally, in such a case, the volume of the garage is large, consequently the time constant of the system has a high value. So a static approach would no longer stay accurate and a dynamic evaluation is needed. With the help of some assumptions, calculations remain rather simple and results can be plotted on nomographs or computed on a programmable handheld calculator. The amount of energy saved may appear very large in some cases. A sizing optimization will be required but also remains easy to compute. The paper presents the method of calculation for a single ventilation level and the optimization of a two-level ventilation.
1982-01-01
The Australian Geographic Team Marsupial solar-powered car
Energy Technology Data Exchange (ETDEWEB)
As in all vehicles of this type, low weight and aerodynamic drag must be achieved without compromising safety, and in an extremely rugged structure. This has been done by using a chrome-molybdenum steel space-frame, surrounded by a Kevlar/foam sandwich body shell. The solar panel wing, which uses a laminar flow section to obtain low drag, does not tilt except when the vehicle is stationary. A high degree of redundancy is built into the vehicle; for example there are two motors and transmissions, the solar array is divided into seven parallel sub-arrays, and the power electronics is multiply redundant. Built entirely in the garage of a suburban house, the Australian Geographic Team Marsupial car cost less than US$50,000 to construct.
1988-01-01
Integrating preventive maintenance, predictive maintenance, and maintenance technical support
Energy Technology Data Exchange (ETDEWEB)
The fundamental tasks of the Oak Ridge Y-12 Plant maintenance operations are planning, scheduling, executing, postmaintenance testing, completing the maintenance job, and supporting these activities with administrative and technical assistance. The Department of Energy (DOE) ``Maintenance Management Program`` guidelines require that we use a graded approach for applying formality and documentation to these maintenance operations. The most-rigorous controls should be placed on maintaining the most-vital systems, structures, and components (SSCs). We must understand risk assessments in order to evaluate which SSCs are most vital. The product of this assessment process is a well-developed understanding of where to apply the most rigor, formality, and documentation. Once we have determined where, we must determine how to apply maintenance so as to mitigate risk. Fundamental to ...
1992-08-06
International Nuclear Information System (INIS)
This paper begins with an introduction to Guangdong Daya Bay Nuclear Power Station (GNPS) and gives a simple introduction to the operations and maintenance documentation system at GNPS. It then will review the maintenance program guidelines base and the associated problems prior to the application of reliability centered maintenance (RCM). How RCM was implemented at GNPS, how the results of RCM analysis were used to optimize the maintenance program and test program, and what is the interface between RCM and the existing maintenance program will be shown. Next, it will show the successful implementation of RCM at GNPS resulted in the following changes: A new understanding of equipment failure challenges operations and maintenance beliefs, maintenance concepts undergo a large change, maintenance program and periodic ...
2003-12-01
30 CFR 77.1606 - Loading and haulage equipment; inspection and maintenance.
...2010-07-01 false Loading and haulage equipment; inspection and maintenance... ยง 77.1606 Loading and haulage equipment; inspection and maintenance. (a) Mobile loading and haulage equipment shall be inspected by a...
2010-07-01
Waste Sampling and Characterization Facility (WSCF). Maintenance Implementation Plan
Energy Technology Data Exchange (ETDEWEB)
This Maintenance Implementation Plan has been developed for maintenance functions associated with the Waste Sampling and Characterization Facility (WSCF). This plan is developed from the guidelines presented by Department of Energy (DOE) Order 4330.4A, Maintenance Management Program (DOE 1990), Chapter II. The objective of this plan is to provide baseline information for establishing and identifying WHC conformance programs and policies applicable to implementation of DOE order 4330.4A guidelines. In addition, this maintenance plan identifies the actions necessary to develop a cost-effective and efficient maintenance program at WSCF.
1993-07-01
Circuit breaker maintenance, sentinels on guard
Energy Technology Data Exchange (ETDEWEB)
Circuit breakers are essential components of every type and size of power system, and their maintenance is a matter of prime importance. This article provides a list of typical circuit breaker maintenance routines for each type of insulating medium and each type of breaker mechanism, and offers a number of useful tips to ensure the success of a circuit breaker maintenance program. It also suggests sources of information about maintenance programs for circuit breakers such as the National Electrical Testing Association's Maintenance Specifications, and companies that specialize in this type of service. 3 tabs.
2003-07-01
Loss of Skeletal Calcium by Patients on Maintenance Dialysis
UK PubMed Central (United Kingdom)
Direct radiological measurements of the mineral content of femoral bone were performed in 13 patients on maintenance dialysis. They were found to be sufficiently sensitive to be used for monitoring,...Full Text Available
1970-08-29
Energy Technology Data Exchange (ETDEWEB)
This research and development is intended to structure a network centering around a center having systematized high-level maintenance technology, by utilizing the technological infrastructure having been built in local areas, together with element technologies possessed by national and private research institutes, universities and colleges. It is also purposed to establish a new industrial system for maintenance to realize high reliability, high operation rate and low cost in plants in certain areas. The present fiscal year had the following achievements: research and development of a maintenance system, a maintenance model, a maintenance vehicle, damage estimating technology for stationary parts such as piping, an anomaly diagnostic system using acoustic emission, an anomaly diagnostic system using wear particles in lubricant, an anti-wear material using surface modification, a ...
1999-03-01
222-S Laboratory maintenance implementation plan
Energy Technology Data Exchange (ETDEWEB)
This Maintenance Improvement Plan has been developed for maintenance functions associated with the 222-S Laboratory. This plan is developed from the guidelines presented by Department of Energy (DOE) Order 4330.4B, Maintenance Management Program (DOE 1994), Chapter 11. The objective of this plan is to provide information for establishing and identifying WMH conformance programs and policies applicable to implementation of DOE Order 4330.4B guidelines. In addition, this maintenance plan identifies the actions necessary to develop a cost effective and efficient maintenance program at 222-S Laboratory. Maintenance activities are mainly going to be performed by existing maintenance organizations within Waste Management Federal Services of Hanford (WMH). Most maintenance performed at 222-S Laboratory is performed by the 222-S ...
1997-08-13
Integrating preventive maintenance, predictive maintenance, and maintenance technical support
Energy Technology Data Exchange (ETDEWEB)
The fundamental tasks of the Oak Ridge Y-12 Plant maintenance operations are planning, scheduling, executing, postmaintenance testing, completing the maintenance job, and supporting these activities with administrative and technical assistance. The Department of Energy (DOE) Maintenance Management Program'' guidelines require that we use a graded approach for applying formality and documentation to these maintenance operations. The most-rigorous controls should be placed on maintaining the most-vital systems, structures, and components (SSCs). We must understand risk assessments in order to evaluate which SSCs are most vital. The product of this assessment process is a well-developed understanding of where to apply the most rigor, formality, and documentation. Once we have determined where, we must determine how to apply maintenance so as to mitigate risk. ...
1992-08-06
Solar Radiation Pressure Binning for the Geosynchronous Orbit
Orbital maintenance parameters for individual satellites or groups of satellites have traditionally
2011-01-01
aged gracefully: premature and accelerated corro - sion, erosion, and stress are raising maintenance costs.Last
Application of wireless sensor system to maintenance of steel construction
International Nuclear Information System (INIS)
... Engineering, Kitakyushu, Fukuoka (Japan) Hattanda, Takumi NTT Advanced
2009-09-01
Control maintenance training program for special safety systems at Bruce B
Energy Technology Data Exchange (ETDEWEB)
It was recognized from the early days of commissioning of Bruce B that Control Maintenance staff would require a level of expertise to be able to maintain Special Safety Systems in proper running order. In the early 80's this was achieved through hands on experience during the original commissioning, troubleshooting and placing of the various systems in service. Control maintenance procedures were developed and implemented as the new systems came available for commissioning, as were operating manuals,training manuals etc. Under the development of the Maintenance Manager, a Conduct of Maintenance section was organized. One of the responsibilities of this section was to develop a series of Maintenance Administrative Procedures (MAPs) that set the standards for maintenance activities including training.
1997-07-01
Waste sampling and characterization facility (WSCF) maintenance implementation plan
Energy Technology Data Exchange (ETDEWEB)
This Maintenance Implementation Plan (MIP) is written to satisfy the requirements of the US Department of Energy (DOE) Order 4330.4B, Maintenance Management Program that specifies the general policy and objectives for the establishment of the DOE controlled maintenance programs. These programs provide for the management and performance of cost effective maintenance and repair of the DOE property, which includes facilities. This document outlines maintenance activities associated with the facilities operated by Waste Management Hanford, Inc. (WMH). The objective of this MIP is to provide baseline information for the control and execution of WMH Facility Maintenance activities relative to the requirements of Order 4330.4B, assessment of the WMH maintenance programs, and actions necessary to maintain compliance with the Order. Section 2.0 ...
1997-08-13
Energy Technology Data Exchange (ETDEWEB)
This study investigates spent fuel cask handling experience at existing nuclear facilities to determine appropriate cask decontamination and maintenance operations at the potential Yucca Mountain repository. These operations are categorized as either routine or nonroutine. Routine cask decontamination and maintenance tasks are performed in the cask preparation area at the repository. Casks are taken offline to a separate cask maintenance area for major nonroutine tasks. The study develops conceptual designs of the cask preparation area and cask maintenance area. The functions, layouts, and major features of these areas are also described.
1992-04-01
Tuberculosis in maintenance haemodialysis patients. Study from an endemic area.
UK PubMed Central (United Kingdom)
One hundred and fifty patients requiring maintenance haemodialysis were investigated to determine the incidence and pattern of tuberculosis. Twenty patients were found to have tuberculosis, giving an...Full Text Available
1981-08-01
Transient and Persistent Hypercalcaemia in Patients Treated by Maintenance Haemodialysis
UK PubMed Central (United Kingdom)
In a group of 32 patients with terminal renal failure the initial hypocalcaemia was corrected after two months' adequate maintenance haemodialysis. In seven patients hypercalcaemia occurred with a...Full Text Available
1968-10-19
UK PubMed Central (United Kingdom)
China’s methadone maintenance treatment program was initiated in 2004 as a small pilot project in just eight sites. It has since expanded into a nationwide program encompassing more than 680...Full Text Available
2010-12-01
Recent uses of robotics for remote inspection and maintenance
International Nuclear Information System (INIS)
This paper documents some of the recent uses of robotics for inspection and maintenance activities in Ontario Hydro's nuclear power plants in areas other than fuel channels and steam generators. 7 figs.
1992-11-22
On scientific and technical maintenance of the nuclear power complex in Ukraine
International Nuclear Information System (INIS)
The article gives a brief description of the state of the nuclear power engineering in Ukraine and in the world as of today. There are basic organizational and practical actions on scientific and technical maintenance of the Ukraine nuclear power complex presented in the article.
2006-01-01
Maintenance and fabrication of electronic equipment
Energy Technology Data Exchange (ETDEWEB)
Solving the maintenance and repair problems of electronic instruments, we have supported the research and development work, and reduced operation costs of the pilot plants in KAERI. In addition, we have improved the maintainability of instruments to use effectively. 18 tabs., 17 figs., 13 refs. (Author) .new.
1995-12-01
Maintenance and fabrication of electronic equipment
Energy Technology Data Exchange (ETDEWEB)
Solving the maintenance and repair problems of electronic instruments, we have supported the research and development work, and reduced operation costs of the pilot plants in KAERI. In addition, we have imposed the maintainability of instruments to use effectively. 15 tabs., 14 figs., 14 refs. (Author) .new.
1994-12-01
Maintenance Implementation Plan for solid waste
Energy Technology Data Exchange (ETDEWEB)
This Maintenance Implementation Plan (MIP) has been developed for. implementation of the US Department of Energy (DOE) Order 4330.4A. Maintenance Implementation Program (DOE 1990) at the Hanford Site Solid Waste complex. It addresses maintenance functions associated with Solid Waste Management, which includes the field operational group and the facilities operational group. An assessment of the existing maintenance programs for Solid Waste was performed, and the results of this assessment were evaluated to determine corrective actions required to bring Solid Waste Maintenance into compliance with the order. The MIP assessment disclosed that most elements defined in the order are currently implemented for Solid Waste. It also identified issues which must be addressed to bring the maintenance function into full compliance with DOE Order 4330.4A. These include ...
1992-06-01
Hardware-oriented reliability centered maintenance for the diesel generators of Wolsung unit 1
Energy Technology Data Exchange (ETDEWEB)
The DGs (Diesel Generators) in NPP (Nuclear Power Plant) has been used for the emergency electric power source to shot down the nuclear reactor safety in case of station blackout. The RCM (Reliability Centered Maintenance) has been applied to DGs for increasing the safety of NPP. The structured defects of DG were not remedied by the improvement of maintenance method. As the first stage of RCM, to find the structured defect, its failure= models were searched and analyzed through the ten year maintenance information. The structured defects such as the air compressor, the lubricating oil pressure, and the insufficient load were the root causes of main failures. The air reservoir reinstallation, the lubricating oil tube modification, the load bank installation, and the qualitative instrumentation were the solutions for the hardware oriented RCM of DGs. There remains the software oriented RCM such as the rejection of useless ...
1997-05-01
UK PubMed Central (United Kingdom)
Transcription factors drive organogenesis, from the initiation of cell fate decisions to the maintenance and implementation of these decisions. The Drosophila embryonic salivary gland...Full Text Available
Changes in Skeletal Mineral in Patients on Prolonged Maintenance Dialysis
UK PubMed Central (United Kingdom)
The measurement of bone loss in patients undergoing maintenance dialysis over a period of two and a half years is reported. The tendency to lose bone is a likely event in renal failure, but depends...Full Text Available
1973-12-01
Maintenance implementation plan for T Plant. Revision 2
Energy Technology Data Exchange (ETDEWEB)
This document is a Maintenance Implementation Plan (MIP) for the T Plant Facility complex located in the 200 West Area of the Hanford Reservation in Washington state. This plan has been developed to provide a disciplined approach to maintenance functions and to describe how the T Plant facility will implement and comply with the regulations according to US DOE order 4330.4B, entitled Maintenance Management Program, Chapter 2.0 {open_quotes}Nuclear Facilities{close_quotes}. Physical structures, systems, processes, as well as all associated equipment specifically assigned to these groups are included in the MIP.
1995-05-01
Coal preparation plant condition-based maintenance
Energy Technology Data Exchange (ETDEWEB)
This report briefly describes the background to colliery engineering maintenance, past experience in machine condition monitoring within coal preparation and the introduction of condition-based maintenance. A role model scheme has been developed for the introduction of condition-based maintenance into coal preparation plants. The report describes the instrumentation and monitoring methods suitable for application to most mineral processing plants, the use of specialist companies to monitor, gather, process and analyse the information and the actions taken by the colliery. Examples of the benefits of operating such a scheme are given in terms of safety, performance and finance. Other problematical aspects of coal processing are examined which have a direct effect on plant condition and availability.
1998-12-31
Aviation Maintenance Safety Articles, January/February 1990
... These are abnormal and an indication of NAVAIRINST 13340.3 identifies these laboratories a possible breakdown in the fuel-handling equip- ...
1990-02-01
Energy Technology Data Exchange (ETDEWEB)
Areas with elevated levels of radioactivity were found throughout both residences, as well as on the surrounding property. Contamination was also found in the garage behind the 105 East structure. The 105 East residence had substantially more contamination than the 107 East residence, as was expected. The chimneys, particularly the rear chimney, from the 105 East residence had extensive contamination, indicating that contaminated materials may have been burned at the site. The high background radiation emanating from this residence made it difficult to establish the relatively lower levels of contamination in the 107 East residence. The property surrounding the 105 East residence was found to have substantial contamination scattered throughout, with the highest level occurring in the backyard. The soil surface contamination seemed to drop markedly (but not entirely) at the property lines. The property surrounding 107 East was found to be less contaminated, although ...
1985-09-01
Role of mechanical vibration in preventive maintenance programmes
Energy Technology Data Exchange (ETDEWEB)
Vibration of machinery plays an important role in preventive maintenance programs of machinery. It can be applied in different phases ranging from simple to computerized programs. The advantages of applying machine condition monitoring programs are numerous since vibration measurement and analysis leads to the early detection of component deterioration. The cost, savings and some details of the vibration preventive maintenance program are discussed.
1989-11-01
Pacific Northwest Laboratory Maintenance Implementation plan
Energy Technology Data Exchange (ETDEWEB)
This Maintenance Implementation plan has been developed for Pacific Northwest Laboratory's (PNL) Nuclear Facilities: 306W, 324, 325, 327 and 329NMF. It is based on a graded approach, self-assessment of the existing maintenance program(s) per the requirements specified by US Department of Energy (DOE) Order 4330.4A, Chapter II, Change {number sign}3. The results of this assessment were evaluated to determine needed improvements in PNL Craft Services' current maintenance program. The objective of this implementation plan is to provide baseline information for compliance to the DOE 4330.4A, and for needed improvements. The prime consideration in applying a graded approach to the Order has been to maintain safe and reliable operations, environmental compliance, safeguards and security, programmatic mission, facility preservation, and/or other facility-specific requirements. Using the results of the ...
1992-06-01
Pacific Northwest Laboratory Maintenance Implementation plan
Energy Technology Data Exchange (ETDEWEB)
This Maintenance Implementation plan has been developed for Pacific Northwest Laboratory`s (PNL) Nuclear Facilities: 306W, 324, 325, 327 and 329NMF. It is based on a graded approach, self-assessment of the existing maintenance program(s) per the requirements specified by US Department of Energy (DOE) Order 4330.4A, Chapter II, Change {number_sign}3. The results of this assessment were evaluated to determine needed improvements in PNL Craft Services` current maintenance program. The objective of this implementation plan is to provide baseline information for compliance to the DOE 4330.4A, and for needed improvements. The prime consideration in applying a graded approach to the Order has been to maintain safe and reliable operations, environmental compliance, safeguards and security, programmatic mission, facility preservation, and/or other facility-specific requirements. Using the results of the self-assessment, PNL has ...
1992-06-01
Opportunistic replacement of fusion power system parts
Energy Technology Data Exchange (ETDEWEB)
This paper describes a maintenance problem in a fusion power plant. The problem is to specify which life limited parts should be replaced when there is an opportunity. The objective is to minimize the cost rate of replacement parts and of maintenance actions while satisfying a power plant availability constraint. The maintenance policy is to look ahead and replace all parts that will reach their life limits within a time called a screen. Longer screens yield greater system availabilities because more parts are replaced prior to their life limits.
1981-10-26
Maintenance viewpoint of a successful reactor program
International Nuclear Information System (INIS)
As the Operating and Support staffs of the FFTF organization have gained experience, the plant reliability and capacity factors have shown a steadily improving trend. The plant capacity factor for Cycle 4 was 99.5%. It is the purpose of this report to describe the evolution of the maintenance organization at the FFTF site from a general support organization to a technically proficient organization playing a major role in planning and performance of plant maintenance evolutions.
1984-06-03
Maintenance implementation plan for the Plutonium Finishing Plant. Revision 3
Energy Technology Data Exchange (ETDEWEB)
This document outlines the Maintenance Implementation Plan (MIP) for the Plutonium Finishing Plant (PFP) located at the Hanford site at Richland, Washington. This MIP describes the PFP maintenance program relative to DOE order 4330.4B. The MIP defines the key actions needed to meet the guidelines of the Order to produce a cost-effective and efficient maintenance program. A previous report identified the presence of significant quantities of Pu-bearing materials within PFP that pose risks to workers. PFP`s current mission is to develop, install and operate processes which will mitigate these risks. The PFP Maintenance strategy is to equip the facility with systems and equipment able to sustain scheduled PFP operations. The current operating run is scheduled to last seven years. Activities following the stabilization operation will involve an Environmental Impact Statement (EIS) to determine future plant ...
1996-03-01
International Nuclear Information System (INIS)
Many types of maintenance activities are performed on contaminated (radioactive) machines and components at the Fast Flux Test Facility (FFTF). When personnel dose levels are within permissible limits, maintenance is performed in contaminated work areas or in gloveboxes. Otherwise, maintenance is performed in the Interim Examination and Maintenance (IEM) Cell, a hot cell that is used to perform tasks that require remote operation. Maintenance is often a combination of manual and remote operation. One such operation was the cleaning of the closed loop ex-vessel machine (CLEM) core component grapple (CCG). The CLEM is used to transfer core components in and out of the reactor vessel. The CCG had not been operating properly due to buildups of metallic sodium and sodium compounds on the outside surface and internal moving parts. This paper tells how the CCG was disassembled and cleaned. ...
1990-11-11
Energy Technology Data Exchange (ETDEWEB)
An overall view of the 1982 plant operating performance is presented. All periods of ON-FEED operation, UNSCHEDULED SHUTDOWNS, and SCHEDULED SHUTDOWNS are accounted for and tabulated. Causes of UNSCHEDULED SHUTDOWNS are identified and discussed. Plant solutions aimed at reducing the effect of similar future shutdowns or preventing recurrence of such shutdowns are explained. Details of repeated, major maintenance problems with various pieces of equipment are presented. Discussion of each problem and solutions found during 1982 are given, where applicable.
1983-12-01
Energy Technology Data Exchange (ETDEWEB)
A summary of the 1983 Critical Solvent Deashing unit performance at the Wilsonville Advanced Coal Liquefaction R and D Facility is presented. All periods of on feed operation, unscheduled shutdowns, and scheduled shutdowns are accounted for and tabulated. Causes of unscheduled shutdowns are identified and discussed. Details of repeated, major maintenance problems with various pieces of equipment are presented. Where applicable, solutions are discussed. Historical operations and maintenance data are presented and used for comparison purposes in order to better indicate areas of improvement in the unit. 4 references, 7 figures, 3 tables.
1985-03-01
Energy Technology Data Exchange (ETDEWEB)
Radioisotope facilities were operated to support research, development and production of radioisotopes. Irradiation facilities were operated to offer irradiation service to the clients. Even though intensive periodical checks and some essential maintenance had been carried out the results of RI facility maintenance seemed to be not much satisfactory due mainly to the shortage of skilled manpower and maintenance expenses. High intensity {gamma} irradiator was normally operated 426 times for overall 3,440 hrs, and the low intensity {gamma} irradiator was operated 157 times for overall 11,092 hrs, respectively. (author)
1998-12-01
Using condition monitoring for maintenance, control of hydro plants
Energy Technology Data Exchange (ETDEWEB)
Electric utilities are actively seeking ways of optimizing the economics of their operations by improving productivity and reducing time and money spent on maintenance. Iberdrola, a Spanish utility, is using advanced machine condition-monitoring technology to centralize control and maintenance of its hydropower projects as a means of achieving those goals. The company is using a blend of technologies to supervise their projects from a regional control center. The monitoring scheme makes use of data from on-line, machine-condition monitors, displays from in-plant audio asnd video equipment, and analysis from the control center`s SCADA system.
1994-12-31
Demonstration experiment on improved radwaste evaporator
Energy Technology Data Exchange (ETDEWEB)
High conductivity liquid waste, which is produced in nuclear power plants, is now processed with radwaste evaporator. The concentrated liquid waste in the evaporator is so highly radioactive and corrosive that the improvement on maintenability and reduction of exposure dose rate are desirable as well as high decontamination factor (DF). Fuji Electric constructed the improved experimental facility of evaporator and carried out an experiment to demonstrate DF, maintenability and controllability of system. As the results, DF, maintenability and controllability were proved to be excellent and its applicability to nuclear power plant was well established.
1988-07-01
Autonomic Management of Maintenance Scheduling in Chord
This paper experimentally evaluates the effects of applying autonomic management to the scheduling of maintenance operations in a deployed Chord network, for various membership churn and workload patterns. Two versions of an autonomic management policy were compared with a static configuration. The autonomic policies varied with respect to the aggressiveness with which they responded to peer access error rates and to wasted maintenance operations. In most experiments, significant improvements due to autonomic management were observed in the performance of routing operations and the quantity of data transmitted between network members. Of the autonomic policies, the more aggressive version gave slightly better results.
2010-01-01
The Daya Bay nuclear power plant performance. An example of international cooperation
International Nuclear Information System (INIS)
Technology transfer is an integral part of Framatome's general approach to its Chinese partners for the Daya Bay, Ling Ao, and Qinshan phase 2 nuclear power plant projects. It has been the subject of major operations covering all activities relevant to project management, design and engineering, manufacturing, and maintenance know-how. This presentation is more particularly devoted to nuclear island maintenance knowledge, which has been extensively transferred by Framatome to the Daya Bay plant owner over a period of four years, through a program including the constitution of mixed Franco-Chinese teams to handle plant maintenance, shadow training of Chinese specialists in the maintenance work performed by Framatome or its subcontractors in France, and theoretical training sessions on equipment mockups in China and France. (author)
1998-10-25
Telomeric recombination induced by dysfunctional telomeres
UK PubMed Central (United Kingdom)
Telomere maintenance is essential for cellular immortality, and most cancer cells maintain their telomeres through the enzyme telomerase. Telomeres and telomerase represent promising anticancer...Full Text Available
2011-01-15
Reliability assessment of reliquefaction systems on LNG carriers
International Nuclear Information System (INIS)
The paper gives an introduction to reliability assessment of reliquefaction systems for boil-off gas (BOG) on LNG carriers with focus on redundancy optimization and maintenance strategies. The reliability modeling is based on a time-dependent Markov approach. Four different system options are studied, with varying degree of redundancy. Failures in the reliquefaction system may require flaring of the BOG, and the associated cost is compared with the cost of introducing redundancy and the cost of onboard maintenance. A model for maintenance optimization is developed and exemplified on a main unit of the reliquefaction system. Reliability and maintenance cost data for reliquefaction systems on LNG ships are very scarce. The input data have been collected from the best available data sources and adjusted by expert judgement. A tailor-made computer program has been developed and may be supplied to interested ...
2008-09-01
Regulatory T cells in human disease and their potential for therapeutic manipulation
UK PubMed Central (United Kingdom)
Regulatory T cells are proposed to play a central role in the maintenance of immunological tolerance in the periphery, and studies in many animal models demonstrate their capacity to inhibit inflammatory...Full Text Available
2006-05-01
Energy Technology Data Exchange (ETDEWEB)
This Site Maintenance Plan has been developed for Pacific Northwest Laboratory's (PNL) Nonnuclear Facilities. It is based on requirements specified by US Department of Energy (DOE) Order 4330.4A, Chapter I, Change No. 4. The objective of this maintenance plan is to provide baseline information for compliance to the DOE Order 4330.4A, to identify needed improvements, and to document the planned maintenance budget for Fiscal Year (FY) 1993 and to estimate maintenance budgets for FY 1994 and FY 1995 for all PNL facilities. Using the results of the self-assessment, PNL has selected 12 of the 36 elements of the Maintenance Program defined by DOE Order 4330.4A, Chapter I, for improvement. The elements selected for improvement are: Facility Condition Inspections; Work Request (Order) System; Formal Job Planning and Estimating; Work Performance (Time) Standards; Priority System; ...
1992-09-28
Energy Technology Data Exchange (ETDEWEB)
This Site Maintenance Plan has been developed for Pacific Northwest Laboratory`s (PNL) Nonnuclear Facilities. It is based on requirements specified by US Department of Energy (DOE) Order 4330.4A, Chapter I, Change No. 4. The objective of this maintenance plan is to provide baseline information for compliance to the DOE Order 4330.4A, to identify needed improvements, and to document the planned maintenance budget for Fiscal Year (FY) 1993 and to estimate maintenance budgets for FY 1994 and FY 1995 for all PNL facilities. Using the results of the self-assessment, PNL has selected 12 of the 36 elements of the Maintenance Program defined by DOE Order 4330.4A, Chapter I, for improvement. The elements selected for improvement are: Facility Condition Inspections; Work Request (Order) System; Formal Job Planning and Estimating; Work Performance (Time) Standards; Priority System; ...
1992-09-28
International Nuclear Information System (INIS)
2007 p. 91 China Fu Pengxuan Daya Bay Nuclear Power Operations and
2006-10-09
Maintenance implementation plan for solid waste management
Energy Technology Data Exchange (ETDEWEB)
This Maintenance Implementation Plan (MIP)was developed for implementation of the U.S. Department of Energy (DOE) Order 4330.4A, A Maintenance Implementation Program (DOE 1990) which has been replaced by 4330.4B (DOE 1994) at the Hanford Site SWM complex. It addresses maintenance functions associated with SWM, which includes the field operational group and the facilities operational group. An assessment of the existing maintenance programs for SWM was performed, and the results of this assessment were evaluated to determine corrective actions required to bring Solid Waste Maintenance into compliance with the order. The objective of this MIP is to provide baseline information for the control and execution of SWM Maintenance activities relative to the requirements of Order 4330.4B, Chapter II. (Nuclear Facilities) It also describes actions that are planned to ...
1996-06-27
Energy Technology Data Exchange (ETDEWEB)
The steam generator inspection and maintenance device has an articulated arm formed at least by two rigid segments connected by a pivot and two plates on the ends of the arms by articulated joints which enable them to rotate about two orthogonal axis. One of the axis is parralel to the axis of the pivot between the arm sections while the other is perpendicular to the surface of the corresponding plate. Each of the plates carries coupling elements which are able to engage with the perforations of the heat exchanger tube plates and also a support for a maintenance tool.
1990-09-21
Implementation strategies and tools for condition based monitoring at nuclear power plants
International Nuclear Information System (INIS)
There is now an acute need to optimize maintenance to improve both reliability and competitiveness of nuclear power plant operation. There is an increasing tendency to move from the preventive (time based) maintenance concept to one dependent on plant and component conditions. In this context, various on-line and off-line condition monitoring and diagnostics, nondestructive inspection techniques and surveillance are used. Component selection for condition based maintenance, parameter selection for monitoring condition, evaluation of condition monitoring results are issues influencing the effectiveness of condition based maintenance. All these selections of components and parameters to be monitored, monitoring and diagnostics techniques to be used, acceptance criteria and trending for condition evaluation, and the economic aspect of predictive maintenance and condition monitoring ...
2009-01-01
Heat shock proteins as emerging therapeutic targets
UK PubMed Central (United Kingdom)
Chaperones (stress proteins) are essential proteins to help the formation and maintenance of the proper conformation of other proteins and to promote cell survival after a large variety of environmental...Full Text Available
2005-11-01
Evaluation of Commercial Magnetic Descalers.
With the increased costs of maintaining boilers and chillers entrepreneurs around the country have offered magnetic and similar devices to facilities as viable alternatives to their maintenance program. This report gives a brief history of some of the pre...
1984-01-01
Draft Regulatory Rule-making for On-line Maintenance of Nuclear Power Plants
International Nuclear Information System (INIS)
Internationally, on-line maintenance (OLM) of nuclear power plants under the operation is prevailed to enhance nuclear safety and economics. In recent years, Korea Hydro and Nuclear Power Co. Ltd. (KHNP) is eager to apply OLM. Ministry of Education, Science and Technology (MEST) has established the related technology development program as an item of 'Overall Planning on Nuclear Safety(2010-2014)' through acceptance to the request of KHNP in 2009. OLM is defined as maintenance that is performed with the main generator connected to the grid. In other words, it means a preventive maintenance to be implemented during the allowable outage time (AOT) with ignoring inoperability of safety-related equipment listed in the technical specifications. The Korea Institute of Nuclear Safety (KINS) is developing the assessment technology of safety concerns for OLM under the auspices of MEST. Draft regulatory rule-making for OLM is devised ...
2010-10-01
International Nuclear Information System (INIS)
Bone integrity and mineral status were studied with a noninvasive method in uremic patients with severe secondary hyperparathyroidism undergoing maintenance hemodialysis.
1999-04-01
Alternative fuel trucks case studies: Running line-haul trucks on ethanol
Energy Technology Data Exchange (ETDEWEB)
This bulletin describes case studies of trucks operating on ethanol fuel. Cost, maintenance and repair, as well as fuel economy are discussed.
1996-10-01
APOPTOSIS BY DIETARY AGENTS FOR PREVENTION AND TREATMENT OF CANCER
UK PubMed Central (United Kingdom)
The role of apoptosis or programmed cell death in the regulation of development and maintenance of homeostasis in multicellular organisms is well established. During the last decade, naturally...Full Text Available
2008-12-01
A DNA recombinant database management system.
UK PubMed Central (United Kingdom)
A set of computer programs is described which constitutes a clone database management system. Maintenance of the database and the stocks of material is designed to be under the control of one person...Full Text Available
1983-07-11
Condition Monitoring in Power Stations; Condition Monitoring im Kraftwerk
Energy Technology Data Exchange (ETDEWEB)
Maintenance of power stations so far operated on the concept of using or extending the expected service life of a machine or plant as far as possible in order to avoid early and costly replacement. This was done by means of time-oriented maintenance, inspection and repair, otherwise called preventive maintenance. A European study on maintenance methods totals the cost of these measures at between 140 to 200 billion DM. One way of reducing these costs is 'predictive maintenance'. Estimated savings are about 8 percent or between 12 and 16 billion DM per year. Predictive maintenance identifies irregulaties of machine parts at an early point in time by means of condition monitoring and can help to cut costs: unplanned repairs can be avoided; repairs can be fitted into production schedules; production will not be disturbed to to unforeseen repairs, ...
1998-07-01
Tehachapi solar thermal system first annual report
Energy Technology Data Exchange (ETDEWEB)
The staff of the Southwest Technology Development Institute (SWTDI), in conjunction with the staff of Industrial Solar Technology (IST), have analyzed the performance, operation, and maintenance of a large solar process heat system in use at the 5,000 inmate California Correctional Institution (CCI) in Tehachapi, CA. This report summarizes the key design features of the solar plant, its construction and maintenance histories through the end of 1991, and the performance data collected at the plant by a dedicated on-site data acquisition system (DAS).
1993-05-01
Energy Technology Data Exchange (ETDEWEB)
Allianz Global Corporate and Specialty AG, the industrial insurance carriers of Allianz Group and AZT Risk and Technology GmbH, have a lot of experience and a comprehensive database about damage of industrial steam turbines and large-scale power generation turbosets. Sound maintenance concepts are the main loss prevention measure, which will be presented and discussed in detail. Some modifications and additions to existing maintenance concepts are also provided.
2008-07-01
Quality assurance requirements for the computer software and safety analyses
International Nuclear Information System (INIS)
The requirements are given as placed on the development, procurement, maintenance, and application of software for the creation or processing of data during the design, construction, operation, repair, maintenance and safety-related upgrading of nuclear power plants. The verification and validation processes are highlighted, and the requirements put on the software documentation are outlined. The general quality assurance principles applied to safety analyses are characterized. (J.B.). 1 ref.
Predictive maintenance plant assessment
Energy Technology Data Exchange (ETDEWEB)
Many electric power utilities are currently employing machine condition monitoring technologies as a means of reducing forced outages and controlling repair costs. These condition monitoring technologies are a set of {open_quotes}tools{close_quotes} to help maintenance and operations personnel identify and repair machinery problems before catastrophic failure occurs. In this way, the analysis of this data becomes a vital link in the daily operation of the plant. Machinery vibration analysis, machinery balancing and alignment, motor current testing, periodic thermography surveys, analysis of lubrication oil samples, performance monitoring, chemistry monitoring, ultrasonic leak detection surveys, and non-destructive inspections are some of the technologies available to perform this condition monitoring. However, even for a small or medium size plant, the sheer volume of data provided by applying all or some of these technologies can be staggering, not to mention the ...
1996-07-01
Osteonecrosis in patients receiving dialysis: report of two cases and review of the literature.
Two patients receiving maintenance dialysis therapy developed osteonecrosis, the first in the humeral head and the second in the talus. Both patients lacked known risk factors for developing osteonecrosis. A possible pathogenic role of secondary hyperparathyroidism in this disorder is suggested. Rheumatologists evaluating patients receiving maintenance dialysis with rheumatic manifestations should be aware of this potential complication. PMID:2185360
1990-03-01
International Nuclear Information System (INIS)
In response to severe maintenance problems caused by the highly corrosive toxic and radioactive substance used in the nuclear reprocessing industry, AEA Technology (formerly the United Kingdom Atomic Energy Authority) has developed a series of power fluidics devices with no moving parts. These maintenance-free devices are described in this article which also explores applications in fields outside their original brief. (UK).
Oil coastal tanker maintenance and availability
Energy Technology Data Exchange (ETDEWEB)
ANCAP (Government's Oil Company of Uruguay) owns a 4000 DWT oil coastal tanker which is mainly used for oil transport in the River Plate, Uruguay and Parana rivers. Availability of the ship is critical because of shortage of available vessels in the region. Full maximum draught of the vessel is 4m , so it can navigate in very shallow waters as it is the case of some places in the Uruguay and Parana rivers. Although the ship was built in 1979, it is a complete double hull, powered by two twin main engines and propellers. Since 1994, several changes in maintenance management have been introduced, in order to increase the availability, thus increasing the total oil volume yearly transported. These changes affected several maintenance items and they also included a modification in the design of part of the cargo tank floors of the ship. As a result of these changes, an increase of 60% of the oil derivatives volume transported yearly was ...
2008-07-01
Maintenance implementation plan for the B Plant/WESF. Revision 4
Energy Technology Data Exchange (ETDEWEB)
This Maintenance Implementation Plan (MIP) has been developed for maintenance functions associated with the B Plant/WESF (Waste Encapsulation Storage Facility) complex. The objective of this plan is to provide baseline information for establishing and identifying WHC conformance programs and policies applicable to implementation of DOE order 4330.4B guidelines. In addition, this maintenance plan identifies the actions necessary to develop a cost-effective and efficient maintenance program at B Plant/WESF. The B Plant WESF facility complex consists of three main facilities and several support structures located in the 200 East Area of the Hanford site. B Plant is a transition facility that is required to ensure safe storage and management of WESF (operating facility) cesium and strontium capsules. B Plant/WESF also contains substantial radiological inventory from previous campaigns. There are no ...
1996-01-01
Energy Technology Data Exchange (ETDEWEB)
Surveillance and maintenance (S & M) of 75 sites were conductd by the Remedial Action Section for the Environmental Restoration Program for surplus facilities and sites contaminated with radioactive materials and/or hazardous chemicals. S & M activities on these sites were conducted from the end of their operating life until final facility disposal or site stabilization. The objectives of the Waste Area Grouping S & M Program are met by maintaining a program of routine S & M as well as by implementing interim corrective maintenance when deemed necessary as a result of site surveillance. This report briefly presents this program`s activities and includes tables indicating tank levels and dry well data for FY 1991.
1991-12-01
Surveillance and maintenance activities of waste area groupings at Oak Ridge National Laboratory
Energy Technology Data Exchange (ETDEWEB)
Surveillance and maintenance (S M) of 75 sites were conductd by the Remedial Action Section for the Environmental Restoration Program for surplus facilities and sites contaminated with radioactive materials and/or hazardous chemicals. S M activities on these sites were conducted from the end of their operating life until final facility disposal or site stabilization. The objectives of the Waste Area Grouping S M Program are met by maintaining a program of routine S M as well as by implementing interim corrective maintenance when deemed necessary as a result of site surveillance. This report briefly presents this program's activities and includes tables indicating tank levels and dry well data for FY 1991.
1991-12-01
British Library Electronic Table of Contents (United Kingdom)
Based on empirical research within the aviation industry we have come to some surprising and sometimes counterintuitive conclusions concerning aircraft maintenance that are relevant for the discussion of social theory and its application towards the explanation and management of socio-technical systems. In this article, the human role in the activity of aircraft maintenance is taken as an example to illustrate the need for critical discussions on social theory in order to better understand safety in socio-technical systems This challenges us to consider the theoretical basis related to how we currently approach the human factor in management of such systems. We propose in the article that Roy Bhaskars' book ?The possibility of naturalism?a philosophical critique of the contemporary human s...
2010-01-01
Plant maintenance and plant life extension issue, 2006
The focus of the March-April issue is on plant maintenance and plant life extension. Major articles/reports in this issue include: Spent fuel: myths and facts, by Jeffrey S. Merrifield, U.S. Nuclear Regulatory Commission; Critical pipe replacement procedure, by Geoff Gilmore, Climax Portable Machine Tools Inc.; Improving maintenance performance, by Larry Meyer and Joe Giuffre, DC Cook Nuclear Plant, American Electric Power; Equipment deficiency intolerance index, by Douglas F. Helms, Tennessee Valley Authority; Plant profile: I and C modernization at Dukovany, by Josef Rosol, CEZ Dukovany NPP, Czech Republic; and, Report: new plant activities.
2006-03-15
Operation and maintenance experiences of pumped-storage plants
Energy Technology Data Exchange (ETDEWEB)
This report presents the results of a study on Operation and Maintenance (O M) practices in hydroelectric pumped storage plants. The objective of this project, which was sponsored by EPRI, is to record the practical knowledge on the O M of a number of the domestic and foreign pumped storage plants which has been accumulated by their operating staff. Civil, geotechnical, mechanical and electrical aspects of O M of the thirty-five plants visited are discussed, and some general conclusions, as warranted by the commonality of the problems, are drawn. These conclusions may be useful to the planners and designers of future pumped storage projects. In general, due to their layout, diversity and different modes of operation, the plants have few common problems which, in most cases, are limited to the mechanical and electrical aspects of the plants' operation. The data on plants' specifications, operation and maintenance were collected ...
1991-05-01
Machine condition monitoring - the way ahead
Energy Technology Data Exchange (ETDEWEB)
During the last fifteen years a variety of instruments and transducers, such as voltage plugs, power transducers, flow and pressure transducers, recorders and tensometers, have been developed for underground use in measuring the performance and technical parameters of prototype machines. The equipment, until recently, has been in a portable form and was found useful by the industry generally, in fault finding and trouble-shooting exercises and in commissioning procedures performed by small teams on a call-out basis. Over the last five years the test equipment has been adapted and the techniques modified to suit individual colliery-based operations with more permanent machine mounted and built-in transducers. At the moment these techniques operate within the framework of a statutory planned preventive maintenance scheme for each mine. This paper discusses the merits of changing from preventive maintenance to condition-based ...
1984-11-01
Western Area Power Administration (Western) is a power marketing agency of the US Department of Energy, with jurisdiction in 15 western states. The Salt Lake City Area (SLCA) of Western performs the agency`s mission in parts of Colorado, New Mexico, Texas, Utah, Arizona, Wyoming, and Nevada. As part of its mission, Western owns, operates, and maintains a system of transmission lines for transmitting bulk electrical energy from points of generation to and between delivery points. Part of that system in southwestern Colorado includes the Blue Mesa-Curecanti and Blue Mesa-Salida 115-kV transmission lines. Western proposes to conduct maintenance and improve its access roads for these two transmission lines. This paper discusses the impacts to the existing environment as well as the environmental consequences resulting from the maintenance and construction that is proposed.
1993-07-01
Cause analysis and preventives for human error events in Daya Bay NPP
International Nuclear Information System (INIS)
Daya Bay Nuclear Power Plant is put into commercial operation in 1994 Until 1996, there are 368 human error events in operating and maintenance area, occupying 39% of total events. These events occurred mainly in the processes of maintenance, test equipment isolation and system on-line, in particular in refuelling and maintenance. The author analyses root causes for human errorievents, which are mainly operator omission or error procedure deficiency; procedure not followed; lack of training; communication failures; work management inadequacy. The protective measures and treatment principle for human error events are also discussed, and several examples applying them are given. Finally, it is put forward that key to prevent human error event lies in the coordination and management, person in charge of work, and good work habits of staffs.
UK PubMed Central (United Kingdom)
Somite boundary formation is crucial for segmentation of vertebrate somites and vertebrae and skeletal muscle morphogenesis. Previously, we developed a Tol2 transposon-mediated...Full Text Available
2008-04-15
UK PubMed Central (United Kingdom)
Between 1970 and 1975, the incidence of new Schistosoma mansoni infections was reduced in 5 villages after each household was provided with its individual water supply and community...Full Text Available
1982-01-01
UNS YMSCP QA support task: Quarterly technical progress report, January 1, 1991--June 30, 1991
Energy Technology Data Exchange (ETDEWEB)
This report describes a quality assurance program plan for the Yucca Mountain Project. Aspects of the plan include: document control, equipment maintenance and calibration, process control, audits, computer software, and inspections. (CBS)
1991-07-30
UK PubMed Central (United Kingdom)
The mini-chromosome maintenance proteins Mcm2–7 are essential for DNA replication. They are loaded onto replication origins during G1 phase of the cell cycle to form a pre-replication complex...Full Text Available
2005-01-01
UK PubMed Central (United Kingdom)
The formation and maintenance of social bonds in adulthood is an essential component of human health. However studies investigating the underlying neurobiology of such behaviors have been scarce....Full Text Available
2008-11-01
British Library Electronic Table of Contents (United Kingdom)
The electric explosion of a conductor being part of an electric cable is studied. It is ascertained that the electric properties of a polymeric dielectric depend nonlinearly on the maintenance of the ultradisperse metal filler. In the course of the numerous heating-cooling processes of an insulator, a streamlining of the structure of a polymeric composite occurs.
2010-01-01
The Notochord, Notochordal cell and CTGF/CCN-2: ongoing activity from development through maturation
UK PubMed Central (United Kingdom)
The growth regulating factor CTGF/CCN-2 is an integral factor in growth and development, connective tissue maintenance, wound repair and cell cycle regulation. It has recently been reported that CTGF/CCN-2...Full Text Available
2008-12-01
Software Configuration Management Plan for the Sodium Removal System
Energy Technology Data Exchange (ETDEWEB)
This document establishers the Software Configuration Management Plan (SCMP) for the software associated with the control system of the Sodium Removal System (SRS) located in the Interim Examination and Maintenance (IEM Cell) Facility of the FFTF Flux Test.
2000-03-06
Sodium sulphur starts to deliver. [High power density battery
Energy Technology Data Exchange (ETDEWEB)
The development of a high power density sodium sulphur battery with a five-year maintenance-free life is described. These batteries are likely to be used in industrial trucks, milk floats, electric cars, storing power station output and power for satellites. (U.K.).
1985-10-03
UK PubMed Central (United Kingdom)
It has become increasing clear that alterations in cellular metabolism have a key role in the generation and maintenance of cancer. Some of the metabolic changes can be attributed to the activation...Full Text Available
2011-06-30
Shelterin complex and associated factors at human telomeres
UK PubMed Central (United Kingdom)
The processes regulating telomere function have major impacts on fundamental issues in human cancer biology. First, active telomere maintenance is almost always required for full oncogenic transformation...Full Text Available
2011-03-01
Seal is successful at Italys largest pumped storage plant
British Library Electronic Table of Contents (United Kingdom)
A HydroSele S seal from James Walker has provided more than two years maintenance-free service at the large Entracque pumped-storage hydroelectric scheme in Italy.
2008-01-01
SIRT1 contributes to telomere maintenance and augments global homologous recombination
UK PubMed Central (United Kingdom)
Yeast Sir2 deacetylase is a component of the silent information regulator (SIR) complex encompassing Sir2/Sir3/Sir4. Sir2 is recruited to telomeres through Rap1, and this complex spreads into subtelomeric...Full Text Available
2010-12-27
Role of plasma membrane calcium ATPase 2 in spinal cord pathology
UK PubMed Central (United Kingdom)
A number of studies have indicated that plasma membrane calcium ATPases (PMCAs) are expressed in the brain and spinal cord and could play important roles not only in the maintenance of cellular calcium...Full Text Available
2010-05-26
UK PubMed Central (United Kingdom)
Stem cells are expected to play a key role in the development and maintenance of organisms, and hold great therapeutic promises. However, a number of questions must be answered to achieve an...Full Text Available
2009-01-01
UK PubMed Central (United Kingdom)
The ubiquitin–proteasome pathway is the principal system for extralysosomal protein degradation in eukaryotic cells, and is essential for the regulation and maintenance of basic cellular processes,...Full Text Available
2007-01-01
Premium performance heating oil - Part 2, Field trial results
Energy Technology Data Exchange (ETDEWEB)
Limited field trial results of a heating oil additive package developed to minimize unscheduled maintenance indicate that it achieves its goal of keeping heating oil systems cleaner. The multifunctional additive package was developed to provide improved fuel oxidation stability, improved corrosion protection, and dispersency. This combination of performance benefits was chosen because we believed it would retard the formation of sludge, as well as allow sludge already present to be carried through the system without fouling the fuel system components (dispersency should keep sludge particles small so they pass through the filtering system). Since many unscheduled maintenance calls are linked to fouling of the fuel filtering system, the overall goal of this technology is to reduce these maintenance calls. Photographic evidence shows that the additive package not only reduces the amount of sludge formed, but even removes ...
1996-07-01
Plasma binding of disopyramide and mono-N-dealkyldisopyramide.
UK PubMed Central (United Kingdom)
1 Measuring total plasma levels of disopyramide (DP) and the main metabolite mono-N-dealkyldisopyramide (MND) in patients on maintenance therapy with DP has shown concentrations of MND comparable with...Full Text Available
1982-11-01
Energy Technology Data Exchange (ETDEWEB)
This paper describes EPRI`s computer based Performance, Operation and Maintenance Management System (``POMMS``) consisting of four (4) modules (``Modules``). These Modules are used to monitor, evaluate and analyze the cost effective operation of simple cycle and combined cycle gas turbine power plants. Inputs to POMMS relating to plant performance, availability and maintenance are monitored, stored in a data acquisition system and analyzed to determine their impact on performance and cost parameters. POMMS was developed by EPRI, Project Manager Fluor Daniel Power Generation Company and by the subcontractors who, together, engineered the individual POMMS Modules while working on EPRI`s Durability Surveillance of Advanced Gas Turbines Project (``Project``). The following modules are described in this paper and may be applied together or individually: Rotating Blade Temperature Measurement and Evaluation System Module (``BTMES``), Data Acquisition ...
1994-12-31
Options available and perceived constraints to implementation
Energy Technology Data Exchange (ETDEWEB)
The economics of renewable energy technologies when deployed in a decentralised manner are more favourable than the simple cost of the fossil fuel generated electricity displaced. They have capital and maintenance cost savings associated with the electrical transmission in infrastructures which are avoided. Worked examples are presented. (UK)
1995-12-31
NIK Stabilization in Osteoclasts Results in Osteoporosis and Enhanced Inflammatory Osteolysis
UK PubMed Central (United Kingdom)
BackgroundMaintenance of healthy bone requires the balanced activities of osteoclasts (OCs), which resorb bone, and osteoblasts, which build bone. Disproportionate action of OCs...Full Text Available
UK PubMed Central (United Kingdom)
Centrioles are intriguing cylindrical organelles composed of triplet microtubules. Proteomic data suggest that a large number of proteins besides tubulin are necessary for the formation and maintenance...Full Text Available
2009-02-15
UK PubMed Central (United Kingdom)
Mitochondrial heat shock protein 70 (mtHSP70) is found to play a primary role in cellular defense against physiological stress like exposure to environmental contaminants and helpful in the maintenance...Full Text Available
2009-09-01
UK PubMed Central (United Kingdom)
BackgroundIdentification of global livestock diversity hotspots and their importance in diversity maintenance is essential for making global conservation efforts. We screened 52...Full Text Available
Mechanism of Catch Force: Tethering of Thick and Thin Filaments by Twitchin
UK PubMed Central (United Kingdom)
Catch is a mechanical state occurring in some invertebrate smooth muscles characterized by high force maintenance and resistance to stretch during extremely slow relaxation. During catch, intracellular...Full Text Available
2010-01-01
UK PubMed Central (United Kingdom)
BackgroundThe widespread use of nutritional supplements among athletes is poorly understood. The prevalence of supplement intake and users' knowledge have been researched independently...Full Text Available
LOUSE-BORNE BACTERIAL PATHOGENS IN LICE (PHTHIRAPTERA) OF RODENTS AND CATTLE FROM EGYPT
... were erroneous. The oriental rat flea, Xenopsylla cheopis Rothschild, is considered to be the primary vector of ... laboratory and production of Weigl's exanthematous typhus vaccine. In Maintenance of hum...
Iron Metabolism in the Anaemia of Chronic Renal Failure. Effects of Dialysis and of Pareuteral Iron
UK PubMed Central (United Kingdom)
Serial studies of iron transport in patients on maintenance dialysis showed normal or raised values in almost all subjects and a transient increase soon after the start of dialysis in three. These...Full Text Available
1969-07-26
Instrumentation and Controls Division progress report, July 1, 1982-July 1, 1984. Volume 1
Energy Technology Data Exchange (ETDEWEB)
Progress is briefly summarized for a large number of projects in the areas of research instruments, measurement and controls engineering, reactor systems, and maintenance management. (LEW)
1984-12-01
Hypertrophy and Heart Failure in Mice Overexpressing the Cardiac Sodium-Calcium Exchanger
UK PubMed Central (United Kingdom)
Background:The cardiac sodium–calcium exchanger (NCX1) is a key sarcolemmal protein for the maintenance of calcium homeostasis in the heart. Since heart failure...Full Text Available
2007-05-01
From 33kV to 132kV cables: Norweb rises to the task
Energy Technology Data Exchange (ETDEWEB)
Responsibility for the operation and maintenance of the bulk of the 132 kV cable network in England and Wales was transferred from the CEGB to the area boards in the 1970s. Norweb has successfully dealt with the increase in work using in-house expertise exclusively.
1982-09-17
Federal Logistics Information System (FLIS) Procedures ...
... II Item Identification 1,2,3,4,5,,3JAN Joint Army-Navy 2 5,6,13 IIM Item Intelligence 2 JANAP Joint Army-Navy-Air 2,7 Maintenance Force Publication ...
1995-01-01
FLIS Procedures Manual. Multiple Application Procedures.
... Volume(s) Volume(s) II Item Identification 1,2,3,4, JANAP Joint Army-Navy- 2,7 5,6,13 Air Force JIM Item Intelligence 2 Publication Maintenance ...
1996-10-01
UK PubMed Central (United Kingdom)
BackgroundObesity has reached epidemic proportions in the United States. It is implicated in the development of a variety of chronic disease states and is associated with increased...Full Text Available
Diesel equipment: is it safe to use underground
Energy Technology Data Exchange (ETDEWEB)
Research indicates that diesel equipment can be used safely in undergound coal mines provided that certain conditions prevail. These conditions are: the machines and engines are approved for underground use, an adequate maintenance and training program is in effect, an adequate monitoring system with proper instrumentation is used, and adequate ventilation is maintained.
1984-04-01
UK PubMed Central (United Kingdom)
BackgroundVariable platelet response to clopidogrel has been widely observed. Studies have shown that the mean aggregation response to clopidogrel can be changed...Full Text Available
2009-05-01
Conservation of spermatogonial stem cell self-renewal signaling between mouse and rat
UK PubMed Central (United Kingdom)
Self-renewal of spermatogonial stem cells (SSCs) is the foundation for maintenance of spermatogenesis throughout life in males and for continuation of a species. The molecular mechanism underlying stem...Full Text Available
2005-10-04
Maintenance energy expenditures were mesured for five rumen bacteria, Selenomonas ruminantium, Butyrivibrio fibrisolvens, Bacteroides ruminicola, Megasphaera elsdenii, and Streptococcus bovis, by using a complex medium with glucose as the carbon source. Large differences (as high as 8.5-fold) in maintenance energy expenditures were seen among these bacteria. The suggestion is made that maintenance requirements could be a significant determinant of bacterial competition in the rumen. Theoretical maximum growth yields, calculated from double reciprocal plots of yield versus dilution rate, were compared to theoretical Y(ATP) values in order to estimate minimum molar adenosine 5'-triphosphate yields from glucose for each bacterium. Results showed that relative yield among the bacteria was growth rate dependent. At high dilution rates, both S. ruminantium and S. bovis produced lactate as their principal fermentation product. At ...
1979-03-01
Chalk Point Cooling Tower Project: Chalk Point Meteorological Station Report. Volume II.
This report documents the operation, maintenance, calibration, data acquisition and data reduction at the Chalk Point Meteorological Station for the period November 15, 1978 through November 15, 1979. Climatological data summaries for each month and calib...
1979-01-01
BALDWIN COUNTY SEPTIC TANK MAINTENANCE DEMONSTRATION PROJECT MX974480
Baldwin County is located on the Gulf of Mexico in Alabama and has a rapidly growing population. Almost 3,000 permits for septic systems are approved annually by by the Baldwin County Health Department. More than 50% of the county's residents rely on septic systems for their d...
UK PubMed Central (United Kingdom)
ObjectiveMaintaining weight loss is a major challenge in obesity treatment. Individuals often indicate that waning motivation prompts cessation of effective weight...Full Text Available
2011-02-01
Repair shops and back-up facilities of the Belchatow mine
Energy Technology Data Exchange (ETDEWEB)
Repair and maintenance for equipment used in the Belchatow brown coal mine and organizational models of repair services in the mine are discussed. Maintenance of earthmoving equipment, spreaders, bucket wheel excavators, loaders and other coal handling equipment, belt conveyors and drive systems for belt conveyors is discussed. Repair shops in the mine also manufacture about 35% of spare parts and elements for equipment used in the mine. Reliability of mining equipment, repairs and repair capacity of the shops are discussed. Organizational models of repair services, equipment used by these services and repair personnel are described. Effects of repair services on operation of the mine are evaluated.
1984-01-01
Development of RCM analysis software for Korean nuclear power plants
Energy Technology Data Exchange (ETDEWEB)
A software called KEPCO RCM workstation (KRCM) has been developed to optimize the maintenance strategies of Korean nuclear power plants. The program modules of the KRCM were designed in a manner that combines EPRI methodologies and KEPRI analysis technique. The KRCM is being applied to the three pilot system, chemical and volume control system, main steam system, and compressed air system of Yonggwang Units 1 and 2. In addition, the KRCM can be utilized as a tool to meet a part of the requirements of maintenance rule (MR) imposed by U.S. NRC. 3 refs., 4 figs. (Author)
1998-12-31
Artificial intelligence: the future in nuclear plant maintenance
Energy Technology Data Exchange (ETDEWEB)
The role of robotics and remote handling equipment in future nuclear power plant maintenance activities is discussed in the context of artificial intelligence applications. Special requirements manipulators, control systems, and man-machine interfaces for nuclear applications are noted. Tasks might include inspection with cameras, eddy current probes, and leak detectors; the collection of material samples; radiation monitoring; and the disassembly, repair and reassembly of a variety of system components. A robot with vision and force sensing and an intelligent control system that can access a knowledge base is schematically described. Recent advances in image interpretation systems are also discussed.
1984-12-01
Artificial intelligence: the future in nuclear plant maintenance
International Nuclear Information System (INIS)
The role of robotics and remote handling equipment in future nuclear power plant maintenance activities is discussed in the context of artificial intelligence applications. Special requirements manipulators, control systems, and man-machine interfaces for nuclear applications are noted. Tasks might include inspection with cameras, eddy current probes, and leak detectors; the collection of material samples; radiation monitoring; and the disassembly, repair and reassembly of a variety of system components. A robot with vision and force sensing and an intelligent control system that can access a knowledge base is schematically described. Recent advances in image interpretation systems are also discussed.
1984-09-23
International Nuclear Information System (INIS)
Due to current social and economical framework, in last years many nuclear power plant owners started a program for the Long Term Operation (LTO)/PLIM (Plant Life Management) of their older nuclear facilities. PLIM/PLEX has already been implemented in many countries (USA, Russia, etc.). This process has many nuclear safety implications, other than strategic and political ones. The need for tailoring the available safety assessment tools to such applications has become urgent in recent years and triggered many research actions. In particular, a PLIM framework requires both a detailed review of the features of the main safety programs (Maintenance, ISI, Surveillance) and a complete integration of these programs into the general management system of the plant. New external factors, such as: large use of subcontractors, need for efficient management of spare parts, request for heavy plant refurbishment programs demand for updated techniques in the overall management of ...
2007-10-15
Energy Technology Data Exchange (ETDEWEB)
The primary objectives of this study were to test two utility analysis models, the Cascio-Ramos Estimate of Performance in Dollars (CREPID) model and Godkewitsch financial utility analysis model and to determine their appropriateness as tools for evaluating training. This study was conducted in conjunction with Philadelphia Electric Company's Nuclear Training Group. Job performance of nuclear maintenance workers was assessed to document the impact of the training program. Assessment of job performance covered six job performance themes. Additionally, front-line nuclear maintenance supervisors were interviewed to determine their perceptions of the nuclear maintenance training. A comparison of supervisor's perceptions and outcomes of the utility analysis models was made to determine the appropriateness of utility analysis as quantitative tools for evaluating the nuclear maintenance ...
1991-01-01
Energy Technology Data Exchange (ETDEWEB)
The low budgets of local governments and Federal States in Germany as well as lack of financial means of renters delaying thorough modernisation of existing heating systems in residential and public buildings, novel heat supply and related customer services are emerging on the market. Heat supply companies and housing construction associations increasingly use modern electronics and telecommunication systems for heating system upgrading and reliable operation and maintenance. This option holds an enormous potential of saving money today and in the future. Installation of remote control and maintenance systems and the related telephone-based services offer fast repair and other services via electronic telecommunications systems, thus saving money and manpower for the repair services of heat suppliers or plumbers, or financial losses due to rents being docked for broken down heating systems. Such remote control and ...
1997-11-01
Energy Technology Data Exchange (ETDEWEB)
The Lincoln Public School District, in Lincoln, Nebraska, recently installed vertical-bore geothermal heat pump systems in four, new, elementary schools. Because the district has consistent maintenance records and procedures, it was possible to study repair, service and corrective maintenance requests for 20 schools in the district. Each school studied provides cooling to over 70% of its total floor area and uses one of the following heating and cooling systems: vertical-bore geothermal heat pumps (GHPs), air-cooled chiller with gas-fired hot water boiler (ACUGHWB), water-cooled chiller with gas-fired hot water boiler (WCCYGHWB), or water-cooled chiller with gas-fired steam boiler (WCUGSB). Preventative maintenance and capital renewal activities were not included in the available database. GHP schools reported average total costs at 2.13 cents/ft{sup 2}-yr, followed by ACC/GHWB schools at 2.88 cents/ft{sup 2}-yr, WCC/GSB ...
1999-06-19
Results of Compact Stellarator Engineering Trade Studies
Energy Technology Data Exchange (ETDEWEB)
number of technical requirements and performance criteria can drive stellarator costs, e.g., tight tolerances, accurate coil positioning, low aspect ratio (compactness), choice of assembly strategy, metrology, and complexity of the stellarator coil geometry. With the completion of a seven-year design and construction effort of the National Compact Stellarator Experiment (NCSX) it is useful to interject the NCSX experience along with the collective experiences of the NCSX stellarator community to improving the stellarator configuration. Can improvements in maintenance be achieved by altering the stellarator magnet configuration with changes in the coil shape or with the combination of trim coils? Can a mechanical configuration be identified that incorporates a partial set of shaped fixed stellarator coils along with some removable coil set to enhance the overall machine maintenance? Are there other approaches that will simplify the concepts, ...
2009-05-27
Results of Compact Stellarator Eengineering Trade Studies
Energy Technology Data Exchange (ETDEWEB)
A number of technical requirements and performance criteria can drive stellarator costs, e.g., tight tolerances, accurate coil positioning, low aspect ratio (compactness), choice of assembly strategy, metrology, and complexity of the stellarator coil geometry. With the completion of a seven-year design and construction effort of the National Compact Stellarator Experiment (NCSX) it is useful to interject the NCSX experience along with the collective experiences of the NCSX stellarator community to improving the stellarator configuration. Can improvements in maintenance be achieved by altering the stellarator magnet configuration with changes in the coil shape or with the combination of trim coils? Can a mechanical configuration be identified that incorporates a partial set of shaped fixed stellarator coils along with some removable coil set to enhance the overall machine maintenance? Are there other approaches that will simplify the concepts, ...
2009-09-25
Energy Technology Data Exchange (ETDEWEB)
The use of deuterium-tritium fuel in the Compact Ignition Tokamak will require applying remote handling technology for ex-vessel maintenance and replacement of machine components. Highly activated and contaminated components of the fusion devices auxiliary systems, such as diagnostics and RF heating, must be replaced using remotely operated maintenance equipment in the test cell. In-vessel remote maintenance included replacement of divertor and first wall hardware, faraday shields, and for an in-vessel inspection system. Provision for remote replacement of a vacuum vessel sector, toroidal field coil or poloidal field ring coil was not included in the project baseline. As a result of recent coil failures experienced at a number of facilities, the CIT project decided to reconsider the question of remote recovery from a coil failure and, in January of 1990, initiated a coil replacement study. This study focused on the ...
1990-01-01
Natural gas pipeline safety in residential areas served by master meters. a handbook
Prepared to make housing project managers, maintenance engineering staff, and designers and architects of HUD - assisted and HUD - insured housing projects and mobile home parks aware of their responsibilities under the Natural Gas Pipeline Safety Act, this handbook provides technical guidance for the reduction of gas leaks and the handling of gas leak incidents in residential areas. The hazards of natural gas, concern over gas safety in residential areas, applicable codes and standards, and sources of information and help are reviewed, along with maintenance and engineering considerations relating to gas pipe failures, the detection of gas leaks, appliance servicing, and pipe installation, repair, and replacement. Housing management considerations are also examined, with attention to recordkeeping and reporting, emergency contingency planning, tenant education, staff qualifications and training, and the development and use of a ...
1975-04-01
Energy Technology Data Exchange (ETDEWEB)
The population masses in many coastal zones in Japan, and human activities are greatly effected. The representative water area is the Tokyo Bay. The population of the Tokyo Bay reaches 26 million at present, and a mass of organic substance and nutrient salt flow into it through rivers and sewage-treatment plants, etc. With the improvement of pollution source countermeasure and sewerage in the area, the inflow load to the Bay gradually decreases, but in the inner bay, red tide is generating in the summertime mainly. And, the anoxic water areas observed in bottom layer in summertime make large effects on the seafood. It is a large theme to clarify formation process of the anoxic water area and to solve this problem for the Tokyo Bay in the twenty-first century. In this paper, changes in water qualities and human activities and fundamental approach of water quality conservation of the Tokyo Bay are described. As maintenance and regeneration countermeasures of the ...
2000-01-05
International Nuclear Information System (INIS)
Power plant components exposed to environments such as water and soil are susceptible to severe corrosion. Many times the effect of corrosion in power plant components can be catastrophic. The problem is aggravated for underground pipelines due to additional factors such as large network of pipelines, proximity to earth mat, high voltage transmission lines, corrosive chemicals, inadequate approach etc. Other components such as condenser water boxes, internals of pipelines, clarifier bridge structures, cooling water inlet gates and pipes etc. which are in continuous contact with water, are subjected to severe corrosion. The nature and locations of all such components are at places which are not accessible for routine maintenance and hence they require long term reliable protection against corrosion. Experience has shown that anti-corrosive coatings are inadequate in preventing corrosion and due to their location regular maintenance coatings are ...
1999-11-22
The application of expert systems technology to rotating machine condition monitoring
Energy Technology Data Exchange (ETDEWEB)
An expert system was developed which helps maintenance personnel diagnose the condition of rotor and stator windings and their cores, in motors and generators rated 2300 V and above. The expert system, called MICAA[TM], used an approach which has been found to be effective for diagnosing medical problems. The program required the user to input machine nameplate information, operating status, and any past test data available. In addition, the program would suggest tests that may be useful, as well as provide guidance to maintenance personnel on what to look for in visual inspections of the machine. The expert system stored and correlated all this information, calculated the overall condition of the component in question, and identified the most likely specific causes of any deterioration. The basic methodology of motor and generator condition assessment, and the architecture and processing performed by MICAA to obtain these capabilities were ...
1995-12-31
Support required from Canada in the operation and maintenance of CANDU stations overseas
International Nuclear Information System (INIS)
The long-term support required from Canada in the operation and maintenance of overseas CANDU nuclear generating stations after commercial operation has commenced is described, with reference entirely to the KANUPP reactor. This includes: technical support to station staff to increase plant reliability and maintainability; assistance with plant improvements; procurement of spares and consumables; and assistance with training programmes. This technical support may be provided by a small number of Canadian staff actually resident at the power station; by short-term visits of Canadian specialists to site and by technical and procurement services provided from Canada. Examples of technical problems experienced are given, showing typical services required from Canada.
Social Skills Training for Taiwanese Students at Risk for Emotional and Behavioral Disorders
Two third-grade Taiwanese students at risk for emotional and behavioral disorders participated in a pull-out, small-group social skills training program developed to promote their skill acquisition and maintenance. Using a multiple baseline across skills design, the authors demonstrated that both participants made marked performance improvement in all three targeted social skills of on-task, appropriate conflict resolution, and cooperation during the intervention condition. Maintenance and follow-up data showed that both participants sustained their use of taught social skills in the training setting and their third-grade classroom, respectively. Social validity measures, including peer sociometric ratings and consumer satisfaction questionnaires and interviews, supported the positive effects of the social skills training program for both participants. Implications for research and practice are discussed. (Contains 2 tables and 2 figures.)
2010-09-01
Smart pigs root out pipeline problems
Energy Technology Data Exchange (ETDEWEB)
In the world of pipeline maintenance, there are pigs and there are intelligent pigs. Intelligent pigs, when launched into a pipeline, carry instrumentation onboard which enables them to gather and record information about problems such as denting, corrosion, and cracking. More basic pigs, on the other hand, look after the routine internal maintenance chores such as cleaning and swabbing, or else perform operational duties such as batching different types of product along the line. The harsh environment in which pigs often operate is described. Aside from the mechanical shocks they undergo when passing welds, bends, and other fittings, they may have to contend with hostile conditions such as hydrogen sulfide environments. High pressure is another factor to consider. In crude oil lines, significant paraffin deposits also can cause problems if they affect the sensors ability to maintain good contact with the pipe wall. In spite of these ...
1983-12-01
Operational procedures - industry observations and opportunities for improvement
Energy Technology Data Exchange (ETDEWEB)
The purpose of this paper is to relate some of the commonly encountered problems with operational procedures in the nuclear industry and offer practical suggestions for their elimination. The paper is based on recent consultant experience in assisting industry clients with human performance related design and assessment initiatives. Operational procedures are a key part of an integrated system design. Procedures provide the specified instructions for actions people are to undertake in operating a facility to achieve production and safety goals. While organizations continue to make substantial investments in procedure development and maintenance, problems with procedures continue to occur, as evidenced through operating inefficiencies, errors, and events. The paper reviews the role procedures play in facility operations, comments on current development and maintenance practices, discusses the extent of human performance related problems ...
2003-07-01
Nuclear data interface retrospective
Energy Technology Data Exchange (ETDEWEB)
The Nuclear Data Interface (NDI) code library and data formats are the standards for multigroup nuclear data at Los Alamos National Laboratory. NDI's analysis, design, implementation, testing, integration, and maintenance required a ten person-year and ongoing effort by the Nuclear Data Team. Their efforts provide a unique, contemporary experience in producing a standard component library. In reflection upon that experience at NDI's decennial, we have identified several factors critical to NDI's success: it addressed real problems with appropriate simplicity, it fully supported all users, it added extra value through the code to the raw nuclear data, and its team went the distance from analysis through maintenance. In this report we review these critical success factors and discuss their implications for future standardization projects.
2008-01-01
International Nuclear Information System (INIS)
This article describes the project for the installation of an additional emergency diesel generator in both Asco and Vandellos NPPs. The basic objectives of this project are to improve the availability of the emergency generation system, in order to provide greater ability to address potential contingencies, and also to increase the flexibility of the preventive periodic maintenance of the emergency diesel generators. This maintenance, that is currently a milestone of the critical path of the refueling outage, will be performed on-line. The new diesel generator will be sized to support all the loads considered in the safety case and also the consumption of its own auxiliary systems, and will be tested for operability assessment on the same periodical basis than the existing ones. The solution adopted will also permit that the N diesel generator may be connected to any bus bar class 1E in a station black-out scenario. (Author)
Health-hazard evaluation report HETA 86-132-1780, Alyeska Pipeline Service Company, Valdez, Alaska
Energy Technology Data Exchange (ETDEWEB)
A study was made of employee exposure to oil sludge and vapors during oil-sludge removal and maintenance activities at the Alyeska Pipeline Service Company's Ballast Water Treatment Facility, Valdez, Alaska. Total hydrocarbons, except benzene, toluene, and xylene, showed concentrations from 371 to 1228mg/m3. Of eight maintenance workers, five reported headache, dizziness, or nausea when working without a respirator. The authors conclude that workers were potentially exposed to benzene vapors and total hydrocarbon vapors exceeding the evaluation criteria for these substances. The authors recommend the use of respiratory protection measures to reduce exposures during work operations.
1987-02-01
FFTF criteria for run-to-cladding-breach experiments
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF) is a liquid-metal-cooled fast reactor, which is designed to test a variety of different structural and fuel materials. A safety analysis is performed for each experiment that is irradiated in FFTF. The FFTF final safety analysis report (FSAR) assumed that all driver fuel assemblies would maintain cladding integrity during normal operations and all design transients. Maintenance of cladding integrity retains three barriers to any fission gas release to the public and also prevents any potential contact between the fuel and coolant. Experiments are, in general, expected to meet the same criterion. Selected experiments can, however, be classified as run-to-cladding-breach experiments (RTCB). The purpose of this paper is to describe alternative acceptance criteria for RTCB experiments that they feel provide protection equivalent to the maintenance of cladding integrity.
1986-06-15
Energy Technology Data Exchange (ETDEWEB)
Operation and maintenance cost estimating methodologies for advanced coal-fired atmospheric circulating fluidized-bed and advanced natural gas-fired combined cycle electric power plants are presented. The purpose of these cost estimating relationships is for use in long range planning and evaluation of the economics of use of these technologies for electric power generation. Projected annual costs of reference plants at ten different sites in the United States, one in each of the ten DOE regions, are given as of 1989, and comparisons are made with existing technologies. A listing of a computer program implementing the methodologies is included. 14 refs., 4 figs., 13 tabs.
1989-12-01
British Library Electronic Table of Contents (United Kingdom)
Abstract Background Atopic dermatitis (AD) affects health and quality of life and it has great impact on both health-care costs and costs to the society. Objectives The objective of this study was to develop a model to analyse the cost-effectiveness of a barrier-strengthening moisturizing cream as maintenance therapy compared with no treatment after initial treatment with betamethasone valerate in adult patients with AD in Sweden. A further aim was to apply a similar health-economic analysis for Denmark, Norway and Finland. Methods A Markov simulation model was developed including data from three sources: (i) efficacy data from a randomized controlled trial including patients with moderate AD treated with either a moisturizing cream or no treatment, (ii) resource utilization and quality of...
2010-01-01
Applications and benefits of the FFTF IEM cell training facility
Energy Technology Data Exchange (ETDEWEB)
The Interim Examination and Maintenance (IEM) Cell is located within the Fast Flux Test Facility (FFTF) Reactor Containment Building. This cell is a complex vertical hot cell whose purpose is to process reactor experiments and to perform maintenance on reactor and refueling components. Because access to this very complex cell is limited, a mock-up called the IEM Training Facility (IEMTF) has been developed. The IEMTF provides the IEM cell with many valuable benefits. Four of these benefits are: (1) development of alternate processing methods; (2) hands-on evaluation of equipment problems; (3) a ready source of verified parts, and (4) training facilities for IEM Cell technicians.
1982-05-01
British Library Electronic Table of Contents (United Kingdom)
Goldstein SL, Mattoo TK, Morgenstern B, Martz K, Stablein D, Talley L. Anemia and growth status in pediatric patients receiving maintenance dialysis after a failed renal transplant course: An NAPRTCS report.Pediatr Transplantation 2006. Copyright 2006 Blackwell Munksgaard Abstract: We conducted a retrospective review of the North American Renal Transplant Cooperative Study (NAPRTCS) Registry transplant and dialysis arms to assess anemia and growth patterns in children who returned to dialysis after a failed renal transplant from January 1, 1992 to February 3, 2004. Of the 1807 potential study subjects, 1451 had transplant removal data (TxIn vs. TxOut) available for analysis. Four hundred and twenty-one of 1451 patients (29%) had a transplant nephrectomy at the time of entry into the NAPRTC...
2007-01-01
XLPE cables move in on underground transmission
Energy Technology Data Exchange (ETDEWEB)
Recent developments in cross-linked polyethylene cables mean they can be used at higher voltages and are starting to replace some oil-filled cables. Their good thermal and electrical properties, easy installation and minimal maintenance have helped their growth. A group at Sumitomo Electric Industries Ltd., Japan is studying the performance of these cables. (author).
1986-02-01
Vortex control of safety enclosures
International Nuclear Information System (INIS)
The vortex amplifier controller has no moving parts and therefore it can have extremely high reliability and avoid the maintenance problems associated with contaminated equipment. The vortex amplifier and its application to ventilation control of radioactive enclosures is described. Reverse purge vortex amplifier ventilation system control is also discussed. (U.K.).
Energy Technology Data Exchange (ETDEWEB)
The report presents technical and economical aspects of underground cables compared to overhead lines in Norway in high voltage transmission systems above 22 kV. The economical comparison between the two options includes capital costs of installation (investment costs), maintenance costs and costs of electrical losses. The main technical issues discussed are reliability and flexibility. 35 refs., 23 figs., 29 tabs.
1994-07-11
UK PubMed Central (United Kingdom)
Previous studies using in vitro cell culture systems have shown the role of the dynamin-related GTPase Opa1 in apoptosis prevention and mitochondrial DNA (mtDNA) maintenance. However, it remains to...Full Text Available
2011-07-01
Structural material irradiations in FFTF
Energy Technology Data Exchange (ETDEWEB)
Information is presented concerning the Materials Open Test Assembly (MOTA); instrumentation and control system; MOTA neutronic data; pressurized tube specimens; stress-rupture measurements for reactor materials; miniature specimen design; the Interim Examination and Maintenance (IEM) cell at the FFTF; support services; and general information concerning the FFTF.
1985-01-01
UK PubMed Central (United Kingdom)
Background/AimsFabry disease is an X-linked recessive and progressive disease caused by α-galactosidase A (α-GaL A) deficiency. We sought to assess the prevalence...Full Text Available
2010-12-01
Robotics: Growing maintenance option for utilities
International Nuclear Information System (INIS)
The use of robots in powerplants is an option that can no longer be ignored. Robots can reduce worker exposure to harmful environments and minimize downtime. As a result, electric utilities are using them more than ever. As robots become more widely accepted, more are being developed to handle an expanding variety of applications. This report begins with an overview of the use of robotics in the electric-utility industry; following that are sections detailing applications for nuclear plants, fossil-fired stations, and transmission and distribution facilities.
Renal bone disease and extraskeletal calcification during dialysis and after transplantation
International Nuclear Information System (INIS)
The author reports 10 studies concerning the diagnosis of renal osteodystrophy and extraskeletal calcification in patients on maintenance hemodialysis as well as some aspects of persistent hyperparathyroidism after renal transplantation. The majority of the studies focus on the value of bone scintigraphy with Tc-99m HEDP in the diagnosis of these disorders. (Auth.).
Reliability analysis of diesel generators of Wolsung unit 1
Energy Technology Data Exchange (ETDEWEB)
As a maintenance optimization project to improve the safety of Wolsung NPP (Nuclear Power Plant), reliability of diesel generators are estimated based on the operating experience, and improvement options are suggested. A reliability measure is suggested for the estimation of reliability for standby safety systems to reflect availability. It is assessed that the reliability of diesel generators can be mush improved if the suggested improvement options are implemented. (Author) 6 refs., 1 tab.
1997-05-01
Reliability analysis of diesel generators of Wolsung Unit 1
Energy Technology Data Exchange (ETDEWEB)
As a maintenance optimization project to improve the safety of Wolsung NPP (Nuclear Power Plant), reliability of diesel generators are estimated based on the operating experience, and improvement options are suggested. A reliability measure is suggested for the estimation of reliability for standby safety systems to reflect availability. It is assessed that the reliability of diesel generators can be much improved if the suggested improvement options are implemented.
1997-05-01
Radionuclide buildup in FFTF [Fast Flux Test Facility] heat transport system cells
International Nuclear Information System (INIS)
The purpose of the work reported in this paper was to measure the radionuclide buildup in primary heat transport system cell No. 3 at the Fast Flux Test Facility (FFTF) and to compare the results with predicted values from a model based on experimental studies and experience at similar reactors. The information obtained is used for maintenance planning and to enhance ability to assess radionuclide buildup in the future at FFTF and in other reactors.
1989-11-26
Energy Technology Data Exchange (ETDEWEB)
The paper deals with the disposal of radioactive waste and the plans for dealing with solid wastes of intermediate and low levels of activity, which are the responsibility of NIREX. NIREX is an executive body which co-ordinates the waste-disposal plans of the main radioactive waste producers. The disposal routes for the active wastes are described including the deep disposal of wastes containing material that will remain active for thousands of years. Requirements for deep burial are outlined with reference to the geology and hydrogeology of the site. Monitoring, maintenance and surveillance are mentioned for the protection of the public.
1984-02-01
Proton beam therapy control system
Energy Technology Data Exchange (ETDEWEB)
A tiered communications architecture for managing network traffic in a distributed system. Communication between client or control computers and a plurality of hardware devices is administered by agent and monitor devices whose activities are coordinated to reduce the number of open channels or sockets. The communications architecture also improves the transparency and scalability of the distributed system by reducing network mapping dependence. The architecture is desirably implemented in a proton beam therapy system to provide flexible security policies which improve patent safety and facilitate system maintenance and development.
2010-09-21
Proceedings of the meeting on the technical study at KEK
International Nuclear Information System (INIS)
Technical studies on constructing the J-PARC (Japan Proton Accelerator Research Complex) are presented by five authors: (1) on the wiring for electromagnets of the 50 GeV synchrotron, (2) on the fast beam-extraction from the 50 GeV synchrotron into two opposite directions, (3) on the target chamber system for the generation of muons, (4) on the design of large aperture electromagnets, and (5) on the maintenance and control of the electromagnet power supplies. (K.Y.)
2006-11-28
International Nuclear Information System (INIS)
This book contains the proceedings of the International Topical Meeting on Remote Systems and Robotics in Hostile Environments. It is organized under the following sessions: Worldwide Applications Overview; Operating Mobile Systems; Sensors and Control Systems; Space Applications; Reactor Operations and Surveillance; Remote Equipment for Hazardous Operations; Future Mobile System; Mining and Construction Operations; Special Applications; Hot Cell Applications; Processing; Reactor Operations and Maintenance; Decontamination and Waste Handling; Remote Handling Development and Demonstration.
Organic Manure and Crop Organic Carbon Returns - Effects on Soil Quality (Soil-QC)
Environmental Research Database
DescriptionThe overall objective of the project is to provide an improved understanding of the processes and linkages through which organic carbon additions influence soil bio-physical and physico-chemical properties. Soil organic carbon (SOC) levels and turnover rates are intimately linked to the soil properties that are important in the maintenance of soil quality and fertility, and sustainable crop production. However, it has been difficult to distinguish the various processes and linkages through which [continued...
2009-01-31
Energy Technology Data Exchange (ETDEWEB)
The WIT telemanagement system simply, reliably and efficient by makes available to us in real time processed, ordered and managed data. Such information has been used to optimise the performance of the drinking water distribution networks on a number of housing estates. This has led to major saving in consumption and on equipment maintenance, thereby improving customer service and obtaining a more rational use of piped water. (Author)
1997-04-01
Modification of fuel bundles and associated optimization of fuel handling equipment
Energy Technology Data Exchange (ETDEWEB)
This is a continuation of research that started in July 2007 at the Deep River Science Academy. The research was related to the effects of endplate thickness and misalignment of fuel bundles in the fuel channel on pressure losses of reactor coolant. Based on this research, a new approach to refueling of the CANDU reactor has been developed. It greatly simplifies fuel handling equipment and increases its reliability. It also reduces required staffing, as well as operating and maintenance costs associated with fuel handling. (author)
2008-07-01
Maintenance of energy systems by means of Internet; Energiesystemen onderhouden met Internet
Energy Technology Data Exchange (ETDEWEB)
Asean Brown Boveri (ABB) developed Glass (Global access for service and support), a monitoring system for the remote control and management of ABB supplied equipment and other equipment through the Internet. Glass can be applied for many different systems, e.g. automated substations of electric power distribution systems or train equipment
1999-04-01
Instrumentation and Controls Division biennial progress report, September 1, 1978-September 1, 1980
Energy Technology Data Exchange (ETDEWEB)
Brief summaries of research work are presented in the following section: overview of the ORNL Instrumentation and Controls Division activities; new developments and methods; reactor instrumentation and controls; measurement and control engineering; electronic engineering; maintenance; studies; services; and development; and division achievements.
1981-06-01
Energy Technology Data Exchange (ETDEWEB)
Heat pumps can be installed indoors or outdoors. H. Klein investigates which site would be preferable for a one-family house. Advantages and disadvantages with regard to necessary space, noise, maintenance and repair are discussed; heat losses in both cases of installations are dealt with. Mathematic calculation shows that indoor installation is safer and more adequate in terms of energy savings.
1982-06-01
Initial Evaluation of USAF Security Forces Distributed Mission Training (SecForDMT).
United States Air Force security forces have a central role in force protection. Their missions include military police services, installation security, air base defense, military working dog functions, and combat arms training and maintenance. Surveys in...
2004-01-01
In-situ maintenance of low-Z limiters in reactors
Energy Technology Data Exchange (ETDEWEB)
In a reactor environment, the surface of a limiter or wall is primarily determined by the mechanism of erosion and deposition of surface material. It should be possible to use pellet injection to reduce net erosion to zero everywhere if low-Z materials are used for the surface. Erosion rates can, in general, be minimized by large area limiters and high plasma temperatures, which transmit power to the walls with less sputtering. Under ideal steady state conditions the wall surface is dominated by metallurgical effects in the wall.
1980-01-01
In-Use Performance Comparison of Hybrid Electric, CNG, and Diesel Buses at New York City Transit
Energy Technology Data Exchange (ETDEWEB)
The National Renewable Energy Laboratory (NREL) evaluated the performance of diesel, compressed natural gas (CNG), and hybrid electric (equipped with BAE Systems? HybriDrive propulsion system) transit buses at New York City Transit (NYCT). CNG, Gen I and Gen II hybrid electric propulsion systems were compared on fuel economy, maintenance and operating costs per mile, and reliability.
2008-06-01
High-pressure compressor series for air and gases; Hochdruckkompressoren-Baureihe fuer Luft und Gase
Energy Technology Data Exchange (ETDEWEB)
The requirements of high-pressure compressors increase. The customers wish still larger quantities of delivery with smaller employment of achievement, minimal oil consumption, service amenability, long intervals of maintenance and so forth. For this, the author of the contribution under consideration presents two series of modular developed high-pressure compressors in compact design for industrial air and technical gases which exactly fulfil these requirements.
2010-06-15
Green design focus: Energy efficiency and environmental responsibility
Energy Technology Data Exchange (ETDEWEB)
This case study illustrates how an existing building can be transformed into a sustainable, green facility through teamwork. This multi-purpose building comprises office space, combustion testing facilities, and microwave communications center. The paper discusses internal systems design, indoor air quality, commissioning, economics, operations and maintenance, and monitoring.
1998-02-01
UK PubMed Central (United Kingdom)
The endoplasmic reticulum (ER) is composed of tubules, sheets, and three-way junctions, resulting in a highly conserved polygonal network in all eukaryotes. The molecular mechanisms responsible for...Full Text Available
2009-11-01
Financial statistics of major US publicly owned electric utilities 1994
Energy Technology Data Exchange (ETDEWEB)
This publication presents 5 years (1990--94) of summary financial data and current year detailed financial data on the major publicly owned electric utilities. Generator and nongenerator summaries are presented. Composite tables present: Aggregates of income statement and balance sheet data, financial indicators, electric operation and maintenance expenses, electric utility plant, number of consumers, sales of electricity, and operating revenue, and electric energy account data.
1995-12-15
Fast cooling of steam turbines. Schnellabkuehlen von Dampfturbinen
Energy Technology Data Exchange (ETDEWEB)
Due to the fast cooling of steam turbines, the shutdown time during maintenance or when repairing faults and damage can be shortened. This booklet describes various processes for cooling steam turbines. It is recommended that fast cooling should be planned in designing new plants and corresponding arrangements should be provided in the form of pipe connections and valves. (DG).
1987-01-01
UK PubMed Central (United Kingdom)
Although human T-cell lymphotropic virus type I (HTLV-I) is the etiologic agent of adult T-cell leukemia/lymphoma (ATL), the role of viral gene expression in the progression to and maintenance of the...Full Text Available
1992-04-01
Energy Technology Data Exchange (ETDEWEB)
Often measures of protection and restoration of reinforced concrete structures are not taken until damage occurs which affects power plant operation. These failures can be avoided by predictive civil engineering maintenance and repair. The consequent application and implementation of a life-time management system for power plant buildings is being suggested. (orig.)
2008-07-01
... and pathogen transmission. Because the ultimate object of stem cell research is cell-based clinical therapy, hES cells should ... 4%) Supported by grants (SC12021 and SC11012) from Stem Cell Research...
Electricity on the rig. Part 3 - New electric rig technology
Energy Technology Data Exchange (ETDEWEB)
The use of an SCR-controlled power system on an offshore drilling rig has lead to an increased acceptance of high technology equipment. Such equipment increases drilling productivity, reduces maintenance, and improves reliability. Most new rigs now have AC squirrel cage motors, brushless AC generators, silicon controlled rectifiers, DC motors, and swtichgear and motor starters. Several opportunities for cost reductions in SCR systems, such as improving the power factor, are studied in this paper.
1983-07-01
De-entrainment of boron by evaporation
Energy Technology Data Exchange (ETDEWEB)
The purpose of this research was to investigate the de-entrainment of boron for evaporators used in nuclear power plants. The forced circulation and semi-continuous type evaporator was used in the experiment. Cyclone and glass-wool packed column which is supposed to provide good decontamination factor as well as easy maintenance, were selected as de-entrainment device to be used in the evaporation of radioactive liquid wastes. The de-entrainment device combined with cyclone and glass-wool column has shown overall DF more than 1000 for boron.
1986-12-01
DOE Manpower Assessment Brief. No. 37: Nuclear-related employment declines in 1995
Energy Technology Data Exchange (ETDEWEB)
The 1993-1995 period represents a time of significant transition for workers engages in nuclear-related activities. Total nuclear-related employment fell markedly from about 300,000 workers in 1993 to 265, 000 in 1995, a 12% decline. This is the lowest level since the 1970s. In 1995, a third of all nuclear-related employment was in the reactor operation and maintenance segment. 6 figs, 1 table.
1996-05-01
Control and monitoring of solar thermal systems with networked embedded systems
Energy Technology Data Exchange (ETDEWEB)
Within this paper the potentialities of using networked embedded systems will be discussed. New embedded hardware with network connectivity allows remote administration and software updates of solar thermal system controllers via internet. System self analysis helps to minimize breakdown times by sending email and SMS to request maintenance staff. (orig.)
2004-07-01
Anodic protection: theory and practice in the prevention of corrosion
Energy Technology Data Exchange (ETDEWEB)
Theoretical and practical aspects of anodic protection for control of corrosion by a wide range of acidic and alkaline solutions are discussed. Chapters are included concerning strategic importance of metals and alloys in modern industry, applications to industrial equipment, descriptions of equipment used in the technique; design, operation and maintenance; economics, scientific principles, characteristics of potentiostats, laboratory tests and procedures, selected application examples and projected future uses. A section is devoted to electrochemical principles.
1981-01-01
ATLAS tile calorimeter electronics upgrade
This presentation summarizes the present upgrade R&D projects in the TileCal collaboration. One project studies the possibility to divide the drawers into smaller minidrawers to simplify maintenance. There are three different front-end projects. There are also projects dealing with high voltage and low voltage distribution, projects for developing PMT dividers, low voltage electronics, data transmission and off-detector electronics.
2011-01-01
Wind power data transmission challenges; Les defis de la transmission de donnees en eolien
Energy Technology Data Exchange (ETDEWEB)
This presentation outlined the corporate history of the Ohmega Group, a small company from Gaspe, Quebec which offers consulting services to the automation and telecommunication sector. It was created in 1982 and has been involved with the wind power industry since 1996. The main services provided by Ohmega Group include electrical and mechanical construction and maintenance services. This paper also reviewed the benefits of using Supervisory Control and Data Acquisition (SCADA) systems in the wind power industry to monitor, control and collect data from wind turbines. The Ohmega Group has provided consulting services to Cartier Wind Energy Inc., a company that was awarded several wind turbine projects by Hydro-Quebec Distribution. The Ohmega Group applied the SCADA system at the Baie des Sables, Anse a Valleau and Carleton wind turbine arrays. The typical architecture of SCADA systems on a wind farm was presented along with Hydro-Quebec's specifications ...
2008-07-01
Energy Technology Data Exchange (ETDEWEB)
The article deals with the following topics: reliability calculation as a basis of a maintenance strategy leads to the knowledge which equipment seems to be critical in the context of a supply interruption; procedure of a risk management; information for a risk assessment: probability of an equipment malfunction, reliability calculation on the system level, failure cost, maintenance cost, further conditions. The article shows an example for a calculation. [German] Die Zuverlaessigkeitsberechnung als Grundlage einer Instandhaltungsstrategie fuehrt zu der Kenntnis, welche Betriebsmittel kritisch im Hinblick auf eine Versorgungsunterbrechung sind. Eine anschliessende Risikobetrachtung schliesst deshalb neben der Betrachtung der nichtgelieferten Energie auch die uebrigen Kosten einer Stoerung ein, die mit den finanziellen Aufwendungen fuer eine Instandhaltung zu vergleichen sind. Im Folgenden wird ein Vorschlag fuer eine Risikobewertung von ...
2004-10-15
Remote handling equipment to robotics - Development within BNFL
International Nuclear Information System (INIS)
There are two major distinct activities involved with reprocessing of nuclear fuel. They are: a) Mechanical handling of the fuel in the head end plants; and b) chemical dissolution and separation of unused fuel, useful by-products and waste products. Plants and facilities associated with the former include significant remote handling equipment that is designed for handling of fuel for normal production processes. These equipment are selected and designed to meet the design throughput of the plant taking into consideration ease of their operation and maintenance in conjunction with statutory regulations on safety and operator dose uptake. Nevertheless, during the life of the plant, there are instances when special equipment is called for to access part of the plant and undertake tasks such as inspection, maintenance and modification to improve the existing process. BNFL has much experience in the design and application of remote handling ...
1995-11-01
Recent developments in the design of conceptual fusion reactors
International Nuclear Information System (INIS)
Since the first round of conceptual fusion reactor designs in 1973 - 1974, there has been considerable progress in design improvement. Two recent tokamak designs of the Wisconsin and Culham groups, with increased plasma beta and wall loading (power density), lead to more compact reactors with easier maintenance. The Reference Theta-Pinch Reactor has undergone considerable upgrading in the design of the first wall insulator and blanket. In addition, a conceptual homopolar energy storage and transfer system has been designed. In the case of the mirror reactor, there are design changes toward improved modular construction and ease of handling, as well as improved direct converters. Conceptual designs of toroidal-multiple-mirror, liner-compression, and reverse-field pinch reactors are also discussed. A design is presented of a toroidal multiple-mirror reactor that combines the advantages of steady-state operation and high-aspect ratio. The liner-compression reactor ...
Energy Technology Data Exchange (ETDEWEB)
The requirements to design nuclear power plants for the effects of an instantaneous double-ended guillotine break (DEGB) of the reactor coolant piping have led to excessive design costs, interference with normal plant operation and maintenance, and unnecessary radiation exposure of plant maintenance personnel. This report describes an aspect of the NRC/Lawrence Livermore National laboratory-sponsored research program aimed at investigating whether the probability of DEGB in Reactor Coolant Loop Piping of nuclear power plants is acceptably small such that the requirements to design for the DEGB effects (e.g., provision of pipe whip restraints) may be removed. This study estimates the probability of indirect DEGB in Reactor Coolant piping as a consequence of seismic-induced structural failures within the containment of the GE supplied boiling water reactor at the Brunswick nuclear power plant. The median probability of indirect DEGB was estimated ...
1986-12-01
Paul Scherrer Institute Scientific Report 1998. Volume IV: Nuclear Energy and Safety
Energy Technology Data Exchange (ETDEWEB)
Nuclear energy related research in Switzerland is concentrated at PSI`s Nuclear Energy and Safety Research Department (NES). The total effort invested in nuclear energy research in 1998 amounted to about 195 py/a and 4.5 millions CHF of investment and maintenance costs. Approximately half of the salary, investment and maintenance costs are externally funded, primarily by the Swiss Utilities, the national co-operative for the disposal of nuclear waste (NAGRA), the Federal Office of Energy (BFE) through the nuclear safety inspectorate (HSK) and the Federal Office for Science and Education (BBW) in connection with the EC Framework Programmes; an increasing part of external funding is coming from domestic and foreign industry (nuclear component and fuel suppliers). The activities of the department are concentrated on three main domains of: Safety and related problems of operating plants; safety features of future reactor and fuel cycles; waste ...
1999-09-01
Energy Technology Data Exchange (ETDEWEB)
The Mixed Waste Landfill occupies 2.6 acres in the north-central portion of Technical Area 3 at Sandia National Laboratories, Albuquerque, New Mexico. The landfill accepted low-level radioactive and mixed waste from March 1959 to December 1988. This report represents the Corrective Measures Study that has been conducted for the Mixed Waste Landfill. The purpose of the study was to identify, develop, and evaluate corrective measures alternatives and recommend the corrective measure(s) to be taken at the site. Based upon detailed evaluation and risk assessment using guidance provided by the U.S. Environmental Protection Agency and the New Mexico Environment Department, the U.S. Department of Energy and Sandia National Laboratories recommend that a vegetative soil cover be deployed as the preferred corrective measure for the Mixed Waste Landfill. The cover would be of sufficient thickness to store precipitation, minimize infiltration and deep percolation, support a healthy vegetative ...
2004-03-01
Integrated thermal and nonthermal treatment technology and subsystem cost sensitivity analysis
Energy Technology Data Exchange (ETDEWEB)
The U.S. Department of Energy`s (DOE) Environmental Management Office of Science and Technology (EM-50) authorized studies on alternative systems for treating contact-handled DOE mixed low-level radioactive waste (MLLW). The on-going Integrated Thermal Treatment Systems` (ITTS) and the Integrated Nonthermal Treatment Systems` (INTS) studies satisfy this request. EM-50 further authorized supporting studies including this technology and subsystem cost sensitivity analysis. This analysis identifies areas where technology development could have the greatest impact on total life cycle system costs. These areas are determined by evaluating the sensitivity of system life cycle costs relative to changes in life cycle component or phase costs, subsystem costs, contingency allowance, facility capacity, operating life, and disposal costs. For all treatment systems, the most cost sensitive life cycle phase is the operations and maintenance phase and the most cost sensitive ...
1997-02-01
Fault detection and fault diagnosis system for engine; Engine no kosho yochi shindan system
Energy Technology Data Exchange (ETDEWEB)
The fault detection and diagnosis system for gas engines was developed to improve the reliability of cogeneration systems (CGS). Most of existing fault detection systems monitor the trend of each part condition of engines and diagnose faults based on trend change, resulting in slow detection. Although early detection systems are available, those are complex, expensive and poor in flexibility and applicability. Since CGSs combined with gas engines increased to 1/3 of the whole CGS, engine troubles cause possible serious faults. The fault diagnosis system was thus developed to prevent serious faults which can early detect, in particular, abnormal conditions of parts around a combustion chamber such as ignition plug, intake valve and exhaust valve by monitoring exhaust pressure waveforms in an exhaust collector. Since this system can detect progressive occurrence frequency of abnormal conditions and degradation of engine parts, it can transfer previous time management and preventive ...
1996-03-29
Energy Technology Data Exchange (ETDEWEB)
Since 1994-95 the University of Applied Sciences Berne is working on weather-proof electric bicycles. The main drawbacks of bicycles, no weather-protection, little comfort of the saddle, the difficulty of climbing hills, are to be eliminated. The electro-mechanical drive-train of 'Ultraleichtmobil ULM BE 2000', developed in 1995-96, was mechanically complicated. This resulted in reduced energy-efficiency and intense maintenance. Too, the drive-train was expensive in production. A fully electrical human-power transmission seemed to be the solution to the problems mentioned above. It is appealing not only to the user of the vehicle, but also to the producer and to the persons doing the maintenance. Following an internal study showing the technical feasibility of such an electrical transmission, a controllable DC/DC-converter which allows to operate a pedal-driven generator at maximum efficiency has been developed. The electrical ...
1999-12-01
Effectively use corrosion testing
Energy Technology Data Exchange (ETDEWEB)
The proper selection of materials of construction is necessary to provide process equipment with optimum performance and corrosion resistance. If properly chosen, the selected material should deteriorate at a uniform, predictable rate, which will allow for maintenance or replacement at scheduled intervals. This concept of risk assessment for predictive maintenance is a minimum requirement for proper materials selection. Materials selection is based on prior service history, field corrosion tests, pilot-plant tests, and laboratory bench-top tests--in that relative order of usefulness. Corrosion test methods are usually divided into two groups: laboratory and field (plant-site) tests. The main difference between the two is that field test specimens are exposed to actual process conditions will all of the variables involved, while laboratory tests are a simulation of field conditions, even if actual process fluids are involved. The paper ...
1995-04-01
Benefits of the use of radioisotopes in industrial gauging and control
International Nuclear Information System (INIS)
Since the radiometric measuring technique was introduced for industrial measuring and control engineering 15 to 20 years ago, the advantages of this technique have become more and more evident and have led to its world-wide application. In the last 15 to 20 years this method has become the standard one in this field. Its major advantages as compared with conventional methods are: contactless measurement; high reliability and accuracy; no mechanically moving parts; and no maintenance required. Despite higher investment costs the application of this method is paid off within a very short time owing to a higher output and the savings in maintenance costs. Some chemo-technical methods can be realized on a grand scale only when radiometric measuring equipment is used - e.g., urea plants, high-pressure polyethylene production. Especially in moisture measurements of blast-furnace coke are the economical advantages significant. Detailed studies have ...
Automated method for determining location and magnitude of leaks inside a PWR containment
Energy Technology Data Exchange (ETDEWEB)
Thermal-hydraulics analysis can be used to determine location and magnitude of leaks inside a pressurized water reactor (PWR) containment, as required by plant technical specifications. The major advantage of this detection method is that it minimizes radiation exposure of maintenance personnel because most of the leak detection process is performed from the control room outside the containment. In addition, such a program allows for the elimination of pipe whip restraints and jet impingement shields, eliminating costs for maintenance of these supports and shields in older plants and lowering construction costs for new plants. Previously, only simple single-node containment models were used for determining leakage magnitude. This paper presents a more sophisticated multinode approach for determining the magnitude and location. The resulting sensitivities to leak can be programmed into the plant's computer system. In this way, the ...
1986-01-01
Energy Technology Data Exchange (ETDEWEB)
The onshore Potiguar basin has nowadays around 5.000 artificial lifting petroleum wells, distributed into 80 fields located on the states of Rio Grande do Norte and Ceara, representing approximately 8% of the national oil production. For that, well maintenance service, realized by Workover Rigs, is essential to preserve the oil productivity of the reservoirs on these fields. However, as the number of rigs is lower than to the number of wells needing maintenance, the task of administrating the management of such equipment according to the demand created by the wells, generates an optimization problem. The decision for a rig intervention on a well depends on parameters such as flow rate, depth, wasted time on intervention, distance from the rig to the next well, type of operation, rig capacity, environmental risks, etc. The objective of this paper is to present an interactive Computational System for Support Decision to the optimized management ...
2004-07-01
Yucca Mountain Task 4, Final report FY 1993
Energy Technology Data Exchange (ETDEWEB)
Four major projects at UNRSL have been supported by NWPO-Neotectonics Yucca Mountain Task 4 funds during the last year: (1) Operation and analysis of data from the UNRSL microearthquake network at Yucca Mountain. (2) Continued operation, maintenance, and calibration of three broadband stations. Limited data analysis was also initiated. (3) Continued review by Dr. Brune of documents and literature related to seismic hazard and tectonics of the Yucca Mountain region. (4) Testing of noise levels in boreholes.
1993-09-30
The root cause analysis of 9DVN002ZV fan failure in Daya Bay Nuclear Power Station
International Nuclear Information System (INIS)
Extensive investigations and detailed analysis of the failure reason of 9DVN002ZV fan in Daya Bay Nuclear Power Station showed that the fan destroy was caused by the failure of non-drive end bear. The direct cause of this bearing' failure was its improper assembly caused by improper maintenance procedure, and the root cause was too small internal radial clearance after mounting. The factor affecting bearing internal radial clearance, the relationship between clearance and operating life time and fan failure process were discussed. (authors)
2005-09-01
The behavioral management of pain: a criticism of a response.
In response to an earlier published paper by Fordyce, some assumptions underlying the behavior management paradigm of chronic pain are critically discussed. While operant treatment has proved successful, the conclusion that operant factors play an important role in the development and maintenance of chronic benign pain is debated. Some empirical studies, regularly used to demonstrate this role, are re-evaluated. An alternative theory is proposed for chronic pain behavior, in which the role of a lower tolerance to proprioceptive stimuli, which may include more than just pain stimuli, is emphasized. PMID:3313200
1987-09-01
Energy Technology Data Exchange (ETDEWEB)
Due to the general market conditions, the construction of steam turbines was greatly reduced in 1987. As in 1986, it came to a downward movement. This situation will heighten in the coming years. The exploitation of devices, which are available by way of the development of EDP in computation, construction, production and operation, leads to considerable improvements. These improvements can only be employed gradually, due to the reduction in production. However, technological progress can be used economically in part in the restoration of old installations. Here turbine construction, the thermodynamical interpretation of gas and steam turbines, developments in the field of conduction technology, piping and materials are described. Also improvements in operation security and operation supervision of the installations is treated, as well as service and maintenance of the plants. (BR) With 131 refs.
1988-04-01
Standard radiation monitoring at Sendai nuclear power station
International Nuclear Information System (INIS)
Standard radiation monitoring has been conducted at Sendai nuclear power station for the purpose of estimation of 'source activity' during refueling outage and evaluation of countermeasures to reduce dose rate. Selected objects of the monitoring are radiation dose rate at maintenance area, radiation field at each equipment and piping, coolant chemistry and plant operation condition. Monitored data indicates that 'source activity' variation can be estimated to some extent using influential factors, and that evaluation of change of loose crud activity, which is presumed to be represented by the dose rate at letdown heat exchanger, is necessary to further explain change in radiation field at main work area. (author).
Simplified RF power system for Wideroe-type linacs
Energy Technology Data Exchange (ETDEWEB)
The RF system for the SuperHILAC injector linac was designed and constructed for minimum system complexity, wide dynamic range, and ease of maintenance. The final amplifier is close coupled to the linac and operates in an efficient semilinear mode, eliminating troublesome transmission lines, modulators, and high level regulators. The system has been operated at over 250 kW, 23 MHz with good regulation. The low level RF electronics are contained in a single chassis adjacent to the RF control computer, which monitors all important operating parameters. A unique 360/sup 0/ phase and amplitude modular is used for precise control and regulation of the accelerating voltage.
1981-03-01
SIMON Host Computer System requirements and recommendations
Energy Technology Data Exchange (ETDEWEB)
Development Service Order {number_sign}90025 requested recommendations for computer hardware, operating systems, and software development utilities based on current and future SIMON software requirements. Since SIMON`s main objective is to be dispatched on missions by an operator with little computer experience, ``user friendly`` hardware and software interfaces are required. Other design criteria include: a fluid software development environment, and hardware and operating systems with minimal maintenance requirements. Also, the hardware should be expandable; extra processor boards should be easily integrated into the existing system. And finally, the use of well established standards for hardware and software should be implemented where practical.
1990-11-29
Robotics and teleoperator-controlled devices
International Nuclear Information System (INIS)
This paper presents a rationale for and a summary of tasks and missions to which mobile and stationary robots and other teleoperator-controlled devices could be assigned in response to the accidental release of radioactive and other hazardous/toxic materials to the environment. Many of these vehicles and devices currently support operation and maintenance of nuclear power plants and other nuclear industry facilities. This paper also discusses specific missions for these devices at the Three Mile Island and Chernobyl nuclear power plant sites at the time of the accidents. Also discussed is the status of devices under development for future applications, as well as research on robotics.
Refocusing Forties operations engineering
Energy Technology Data Exchange (ETDEWEB)
Faced with a changing business emphasis, plus the need to reduce operations and maintenance costs in the North Sea, the Forties Field engineering partnership between BP and Brown and Root recognised the need to make radical changes in its organisational structure. An innovative change management programme was planned and executed inside 12 months with the purpose of right-sizing the Forties Operations Engineering team. Not only has the initiative succeeded in cutting costs by 40 per cent; it has also enhanced the quality of engineering support services supplied to the BP Forties platforms. (author)
1996-12-31
R and D on Control Rod Magnetic Suspension Drive Mechanism of CARR
Energy Technology Data Exchange (ETDEWEB)
This paper deal with the research and develop (R and D) on Control Rod Magnetic Suspension Drive Mechanism (MSDM) of CARR. The MSDM is made up of tube, coil, armature, step motor, lead screw etc. The MSDM use electromagnetics as its main principle. The open solenoid electromagnet technique is employed to implement suspension function. It has advantages of high drive precision, high safety feature, good running reliability, easy maintenance and good economical property. The R and D process of MSDM has three phases including single coil electromagnet, principle prototype and engineering prototype. (author)
2011-07-01
Proceedings of the third international conference on containment design and operation. v.1
International Nuclear Information System (INIS)
The second international conference on containment design and operation included sessions on the following topics: performance and regulatory requirements; radionuclide behaviour; severe accident design and analysis; operation, maintenance, leaking and aging of containment systems; thermal hydraulic behaviour of containment systems; hydrogen mixing and mitigation; design methods and concepts; code validation; structural analysis and response tests; passive safety systems; aerosol behaviour; containment reliability, integrity, and risk assessment; hydrogen deflagration and detonation. Due prominence was given to CANDU and other PHWR reactors. The individual papers have been abstracted separately.
1994-10-19
International Nuclear Information System (INIS)
The symposium covers papers under different sections namely, (i) Core physics and Fuel management, (ii) Commissioning of facilities and systems, (iii) Operational experience and Human resource development, (iv) Fuel handling, Maintenance management and Surveillance, (v) Instrumentation and Control and Power supply systems, (vi) Analysis, modifications and developments for enhancing operational safety, (vii) Chemistry control and Effluent management, (viii) Radiation and industrial safety and (ix) Steam generators, Turbo-generators and other auxiliaries. Papers relevant to INIS are indexed separately. (author)
2006-11-13
This workshop covered the latest practical engineering and operational management applications and techniques that have been found to enhance operational costs, reliability, and flexibility, with topics such as establishing the optimal refrigeration design cycle and operating design points; utility management; manpower scheduling; plant control philosophy and automation; short and long term maintenance scheduling; refrigerant loss detection and control; system contamination; component reliability; and equipment technical performance issues.
2006-11-10
International Nuclear Information System (INIS)
Full text: Many studies have demonstrated significant declines in 24-hour energy expenditure (TEE) measured by whole body calorimetry with either the process of weight loss or the maintenance of reduced body weight. The aims of this study were to determine the effect of weight loss and two weeks of weight maintenance on TEE using ["1"4C]-bicarbonate-urea, Eleven subjects (6 males, 5 females), mean (#+-#SE) age 50 #+-# 3 years, BMI 34.1 #+-# 2.1 kg/m2 and body fat 38.7 #+-# 3% were studied before and after a decrease in body weight of > 8% over a period of 8 weeks, followed by two weeks of weight maintenance. Weight loss was induced using the combination of Modifast and one small meal a day (#approx#3.34 MJ/day). Body composition (DEXA), resting energy expenditure (REE) and the thermic effect of a 2.7 MJ test meal (TEF) were measured in addition to TEE at week 2 and again at week 12. Diet was assessed using diaries and ...
2002-05-04
Making resource recovery economical
Energy Technology Data Exchange (ETDEWEB)
Four major reasons why municipal resource recovery operations are uneconomical are analyzed. These reasons are: alternative municipal waste disposal methods are artificially underpriced when the costs of meeting modern environmental standards are considered; high capital costs related to the procurement of resource recovery systems and the marketing of recovered resources; uncertainties associated with the costs and performance of resource recovery technologies; and construction and operating risks of municipal waste resource recovery systems. If resource recovery is to become economical, purchasers of plants must develop innovative process designs and equipment and formulate new operating and maintenance procedures. (1 photo)
1980-01-01
Machine condition monitoring using neural networks and the likelihood function
Energy Technology Data Exchange (ETDEWEB)
A model-based technique incorporating neural networks has been developed for process monitoring. The technique is intended for processes where the uncertainty in the reference model is larger than desired but where process measurements providing additional information about the behavior of the system are available. This data is used to reduce the uncertainty of the model. The technique has been implemented in a real-time system for monitoring operational changes of mechanical equipment for use in predictive maintenance applications. Tests on a peristaltic pump were conducted and demonstrate the advantages of the proposed technique.
1997-09-01
Long-term preventive maintenance of instrumentation control equipment for PWR plants
International Nuclear Information System (INIS)
Since the PWR plants in Japan have been operated more than 30 years, main instrumentation control equipment of analog systems has been renewed to digital control systems. Renewal works had to be done in short period within periodical inspection term and for several facilities. The Mitsubishi LTD group had been provided with these market needs by its digital control system (MELTAC-NplusR 3) applicable to main instrumentation control equipment for primary and secondary systems and had already finished the renewal for practical plants. (T. Tanaka)
2006-02-01
Energy Technology Data Exchange (ETDEWEB)
The major distributor and retailer of electrical power to Auckland, New Zealand, is Mercury Energy Limited. Following the sequential failure of the four 110kV underground cables, two gas-filled and two oil-filled, which supply the central business district, power was interrupted for 29 days from the 20th February 1998. A government inquiry was instituted, to examine what happened, why, and what lessons could be drawn for the future. Inadequacies in Mercury Energy`s cable maintenance and operating procedures were identified. The findings of the inquiry and its recommendations are reported. (UK)
1998-08-01
HANARO cooling features: design and experience
International Nuclear Information System (INIS)
In order to achieve the safe core cooling during normal operation and upset conditions, HANARO adopted an upward forced convection cooling system with dual containment arrangements instead of the forced downward flow system popularly used in the majority of forced convection cooling research reactors. This kind of upward flow system was selected by comparing the relative merits of upward and downward flow systems from various points of view such as safety, performance, maintenance. However, several operational matters which were not regarded as serious at design come out during operation. In this paper are presented the design and operational experiences on the unique cooling features of HANARO. (author)
1999-08-01
Facility Safety Plan B360 Complex Biohazardous Operations CMLS-412r0
This Addendum to the Facility Safety Plan (FSP) 360 Complex describes the safety requirements for the safe conduct of all biohazardous research operations in all buildings within the 360 complex program areas. These requirements include all the responsibilities and authorities of building personnel, operational hazards, and environmental concerns and their controls. In addition, this Addendum prescribes facility-specific training requirements and emergency controls, as well as maintenance and quality assurance requirements for ES&H-related building systems.
2007-01-08
Electricity exchanges across international borders - 1983
Energy Technology Data Exchange (ETDEWEB)
This report summarizes the electricity exchanges between the US and Mexico and Canada during calendar year 1983. The construction, operation and maintenance of any electric transmission facility which crosses an international border of the United States requires a Presidential Permit. These permits have been granted by the Department of Energy (DOE) since its formation in 1977. Between 1953 and 1977, these permits were issued by the former Federal Power Commission. Prior to 1953, they were issued by the President of the United States. Presidential Permits require that an annual report be filed by the permit holder detailing all transactions with the foreign country.
1984-09-01
Dynamic stabilizer on-line experience
Energy Technology Data Exchange (ETDEWEB)
A brief description is presented of the Westinghouse Torsional Dynamic Stabilizer, which was developed primarily as a countermeasure to ''torsional interaction'' subsynchronous resonance. Two such systems were installed and commissioned at the San Juan Generating Station, Waterflow, New Mexico in July, 1980. This paper describes the maintenance procedures and operating experience to date of these two units. The only known instance of operation at the high level bias point of the Stabilizer appears to indicate that the unit helped to dampen a turbine-generator shaft oscillation transient.
1984-01-01
Energy Technology Data Exchange (ETDEWEB)
The profitability of combustion turbines intended for export is of extreme importance for Electricite de France. It is principally during the development phase of a project that one can ensure resect of two indissociable factors, essential to the per-kWh production cost: global operating costs and performance in terms of reliability and availability. The approach proposed here advocates the global acquisition of the installation and its logistic support. Generally applicable recommendations are given. They enable integrating in the future plant specifications all requirements relative to plant reliability, availability, maintainability and logistic support. They are structured according to type: expression of needs and management factors. (orig.) 4 refs.
1998-12-31
Controlling transit-bus emissions and improving management
Energy Technology Data Exchange (ETDEWEB)
The 8 papers in the report deal with the following areas: Introduction to diesel particulate emissions, alternative fuels, and the transit industry; Technical problems and policy issues associated with the 1991 bus emissions standards; Reducing transit bus emissions: comparative costs and benefits of methanol, particulate traps, and fuel modification; Effects of applying emissions averaging, trading, and banking to transit buses; Strategic review of heavy-duty engine emission regulations and alternate fuels; Meeting bus emissions standards--a perspective; Economic evaluation of bus maintenance contracting; Objectives for a transit-bus-fleet management data, information, and knowledge exchange.
1988-01-01
Conceptual design of the ATLAS EM muon chamber support structures
The conceptual design of the support structures of the EM muon chambers is presented. On each side of the detector the EM chambers are arranged in four layers: one layer of MDTs and the three layers of TGCs. The chambers are mounted on four individual wheel structures per side. The four wheels are inclined by 1.23% and suspended from two longitudinal beams parallel to the beam axis. In order to allow for the opening of the ATLAS detector the wheels can be displaced longitudinally over a distance of 6 m. In addition individual wheels can be separated from each other by up to 1 m for maintenance purposes.
1998-01-01
CRC handbook of lubrication. Theory and practice of tribology: Volume II: Theory and design
Energy Technology Data Exchange (ETDEWEB)
This handbook covers the general area of lubrication and tribology in all its facets: friction, wear lubricants (liquid, solid, and gas), greases, lubrication principles, applications to various mechanisms, design principles of devices incorporating lubrication, maintenance, lubrication scheduling, and standardized tests; as well as environmental problems and conservation. The information contained in these two volumes will aid in achieving effective lubrication for control of friction and wear, and is another step to improve understanding of the complex factors involved in tribology. Both metric and English units are provided throughout both volumes.
1984-01-01
British Library Electronic Table of Contents (United Kingdom)
The establishment of workable collaborative relations with indigenous elites formed a vital part of the maintenance of the British Empire. This was especially so in the Malay States, where the Malay rulers enjoyed considerable local prestige as religious leaders and as the organising principle of Malay society itself. As the case of Sultan Ibrahim of Johore demonstrates, nevertheless, indigenous collaborators were no mere puppets and enjoyed considerable freedom of action to frustrate and impede the policies of their imperial overlords. Sultan Ibrahim presents a particularly interesting case study as his 64-year reign more or less spanned the entire period of formal British rule in Malaya.
2008-01-01
Borehole heat store design optimization. The SmartStore model
Energy Technology Data Exchange (ETDEWEB)
The SmartStore model was developed to determine the optimum design of borehole heat stores as a function of different design parameters. The optimum design is defined as the design that achieves the storage task with a minimum annual storage cost. The annual storage cost is the sum of annual costs of investment, operation, maintenance and heat loss. The PC-model has a user-friendly lay-out and gives a fast pre-design of borehole heat stores. In this article the model is briefly described. It is also shown that the technical design of the store is influenced by varying technical properties of the storage volume, but also by the cost of heat. (orig.)
1994-12-31
Energy Technology Data Exchange (ETDEWEB)
Bone integrity and mineral status were studied with a noninvasive method in uremic patients with severe secondary hyperparathyroidism undergoing maintenance hemodialysis. [Italian] Gli autori propongono un metodo non invasivo per studiare la densita' minerale e le caratteristiche geometriche e biomeccaniche dell'osso nei pazienti uremici affetti da iperparatiroidismo secondario grave.
1999-04-01
Application aspects of the static frequency converter system
Energy Technology Data Exchange (ETDEWEB)
The use of reversible pump/turbine sets in pumped storage has created a requirement for rapid reversibility. Softstart technology, based on static frequency converters (SFC) has evolved to such an extent that it is now the best choice for serving this purpose, both from a technical and from an economic point of view. The objective of our paper is to give the owners of pumped storage plants and those persons responsible for the selection, the operation or the maintenance of the electrical equipment the necessary insight into the SFC functions, features and all other application related aspects, to facilitate their decision making process. Case studies are included.
1995-12-31
Energy Technology Data Exchange (ETDEWEB)
Past airfoil configurations have been used to improve aerodynamic performance and engine efficiencies. The present airfoil configuration further increases component life and reduces maintenance by reducing internal stress within the airfoil itself. The airfoil includes a chord and a span. Each of the chord and the span has a bow being summed to form a generally "C" configuration of the airfoil. The generally "C" configuration includes a compound bow in which internal stresses resulting from a thermal temperature gradient are reduced. The structural configuration reduces internal stresses resulting from thermal expansion.
1998-01-01
Advances and innovations in dialysis in the 21st century.
Patients with end stage renal failure (ESRD) require renal replacement therapy in the form of dialysis or renal transplantation. There is an increasing number of people receiving maintenance dialysis as patients with ESRD are increasing faster than the supply of transplantable organs. The mortality rate on dialysis is 4-6 times that of the general population and is substantially reduced by transplantation. For the past 8 years, dialysis research has focused on improving patient outcomes and quality of life on dialysis. This review examines recent advances in haemodialysis and peritoneal dialysis in a historical context and considers future research possibilities. PMID:19329705
2009-02-01
A neuro-fuzzy technique for fault diagnosis and its application to rotating machinery
Energy Technology Data Exchange (ETDEWEB)
Malfunctions in machinery are often sources of reduced productivity and increased maintenance costs in various industrial applications. For this reason, machine condition monitoring is being pursued to recognise incipient faults. In this paper, the fault diagnostic problem is tackled within a neuro-fuzzy approach to pattern classification. Besides the primary purpose of a high rate of correct classification, the proposed neuro-fuzzy approach also aims at obtaining an easily interpretable classification model. The efficiency of the approach is verified with respect to a literature problem and then applied to a case of motor bearing fault classification.
2009-01-15
Energy Technology Data Exchange (ETDEWEB)
Petro-Canada's Terra Nova offshore oil platform was designed with the expectation that its Floating, Production, Storage and Offloading (FPSO) vessel would be taken off location for maintenance and modifications work within the first 10 years of operation. Petro-Canada's 2006 extended Turnaround project was initiated to prepare for the maintenance and transport of the FPSO. The project aimed to execute an extended turnaround in approximately 90 days. The cost of the project was estimated at $190.5 million. Shutdown occurred early on May 7, 2006 due to the failure of a generator gearbox. Staff were increased from 80 to 120 to complete critical preparation work. On June 17, the FPSO was disconnected and departed for Conception Bay. A turret cover plate was installed, and the FPSO began its voyage to a Rotterdam shipyard in the Netherlands. In order to complete the journey, a comprehensive marine transit manual and emergency ...
2006-07-01
International Nuclear Information System (INIS)
Monitoring nuclear plants components enable to save on operation and maintenance costs by reducing incidents gravity and casual plant stoppages thank to early detection and fast diagnosis. Improving the knowledge of the behaviour of the plant will also allow to optimize maintenance and to increase plant life. In order to improve monitoring and diagnosis capabilities in nuclear power plants. Electricite de France (EDF) is extending the existing data processing chains towards automatic aided interpretation and diagnosis. Therefore, EDF has designed an integrated monitoring and diagnosis assistance system: PSAD-Poste de Surveillance et d'Aide au Diagnostic, including several monitoring functions of the main components. It integrates on-line monitoring, off-line diagnosis and knowledge based systems. PSAD stations provide homogeneous aids to diagnosis which enable plant personnel to pinpoint the mechanical behaviour of plant equipment. The ...
1997-04-14
Management of long term radiological liabilities: Stewardship challenges
International Nuclear Information System (INIS)
The IAEA attaches great importance to the dissemination of information that can assist Member States with the development, implementation, maintenance and continuous improvement of systems, programmes and activities that support the nuclear fuel cycle and nuclear applications, including management of the legacy of past practices and accidents. In this connection, the IAEA has initiated a comprehensive programme of work covering all aspects of environmental remediation: - Technical and non-technical factors, including costs, that influence environmental remediation strategies and pertinent decision making; - Site characterization techniques and strategies; - Assessment of remediation technologies; - Techniques and strategies for post-remediation compliance monitoring; - Special issues such as the remediation of sites with dispersed radioactive contamination or mixed contamination by hazardous and radioactive substances. Experience in Member States has shown that ...
2006-01-01
Energy Technology Data Exchange (ETDEWEB)
A transplant experiment was conducted to determine whether standard metabolic rate (SMR) of a freshwater shrimp (Palaeomonetes paludosus) would be affected by exposure to trace element-enriched coal combustion waste (coal ash). Shrimp were transplanted into replicate cages in a coal ash-polluted site and a reference site for 8 months. The coal ash-polluted site was characterized by elevated sediment concentrations of As, Cd, Cr, Cu, Ni, Pb and Se compared to sediments in the reference site. After 8 months in the study sites, shrimp in the polluted site appeared to have accumulated As, Cd and Se from the habitat, but there were on differences in survival between the study sites. However, mean SMR of shrimp (measured as O{sub 2} consumption at rest) held in the polluted site was 51% higher than mean SMR of shrimp held in the reference site. The elevation in SMR indicates that the energetic costs of maintenance are greater for shrimp chronically exposed to the ...
1998-12-01
`TUNDTEMP` - an advisory tool for the continuous steel casting process
Energy Technology Data Exchange (ETDEWEB)
This report summarizes the major features of the advisory tool `TUNDTEMP`, developed to act as a decision support in the continuous steel casting process. `TUNDTEMP` provides a means to predict abnormal phenomena of temperature origin in the casting that may be difficult to foresee in practical situations. The heart of the system is a semi-empirical calculation model that yields an estimate of the evolution of the tundish temperature of the liquid steel on the basis of a few important casting factors. The user interface of the system is to a large extent based on the visual presentation of the simulated results. The system also contains an optional rule based mechanism that provides assistance in the result interpretation and, if wished, linguistically formulates action recommendations. A separate program has been built for the tuning of the calculation model and for maintenance of the system. At the end of the report, the different tuning parameters are listed and ...
1993-11-01
VVER technology: Czechs check out and choose bitumenisation
International Nuclear Information System (INIS)
Bituminization has to be selected as the process for conditioning radioactive liquid wastes arising from the two VVER V-230 reactors being built at Temelin in the Czech Republic. In the process, a thin-film evaporator, operating at a waste-product temperature of 160"oC, evaporates all free water from the waste effluents. Remaining solids are homogeneously dispersed in a bitumen matrix which solidifies through natural cooling of the binder. The relative simplicity of the process reduces construction costs for on-line waste facilities and operating costs are less given the cheap basic material and simple maintenance. The reliability of the process has been demonstrated at Western reactors and reprocessing plants though adaptations have had to be made to accept VVER effluents. (UK).
1994-01-01
UK Achievements in the application of power fluidic technology for nuclear processing plants
International Nuclear Information System (INIS)
Power Fluidic systems for the control of liquids and gaseous flows have been adopted for use in radioactive processing plants in the UK. These devices are intrinsically reliable with no mechanical moving parts because they are able to make use of the hydrodynamics of the fluids being controlled. This reliability feature leads to a zero cell maintenance concept and the elimination of mechanical drive/control systems in cell. The first phase of the development work led to their use in the Fast Reactor Reprocessing Plant at Dounreay and the Highly Active Liquor Storage facility at Sellafield. The success of these early developments has led to an extensive development programme for an extended range of applications in the Thermal Oxide Reprocessing Plant and its associated waste treatment facilities at Sellafield. The technology has now been fully demonstrated and adopted for these plants with considerable benefit over a wide range of applications.
British Library Electronic Table of Contents (United Kingdom)
The mammalian placenta consists of different trophoblast cell types that assist in the variety of functions required for the maintenance of pregnancy. In rodents, labyrinthine trophoblasts of the placenta are especially important, because they are capable of differentiating into fused labyrinthine cells, which form the feto-maternal exchange surface. Even though the molecular signals triggering labyrinthine trophoblast differentiation are poorly understood, transforming growth factor-b (TGF-b) has been shown to be present in the placental environment and alter trophoblast development. In this study, we investigated the effects of TGF-b on the differentiation of the labyrinthine trophoblast stem cell lines SM10 and HRP-1. RT-PCR analyses demonstrated that while the molecular expression of l...
2005-01-01
A bioartificial kidney, which is composed of a membrane cartridge with renal epithelial cells, can substitute important kidney functions in patients with renal failure. A particular challenge is the maintenance of monolayer integrity and specialized renal epithelial cell functions ex vivo. We hypothesized that this can be improved by electro-spun, supramolecular polymer membranes which show clear benefits in ease of processability. We found that after 7?d, in comparison to conventional microporous membranes, renal tubular cells cultured on top of our fibrous supramolecular membranes formed polarized monolayers, which is prerequisite for a well-functioning bioartificial kidney. In future, these supramolecular membranes allow for incorporation of peptides that may increase cell function even further. PMID:20715132
2010-11-10
The temporal evolution of coronal loops observed by GOES-SXI
We study the temporal evolution of coronal loops using data from the Solar X-ray Imager (SXI) on board of GOES-12. This instrument allows us to follow in detail the full lifetime of coronal loops. The observed light curves suggest three somewhat distinct evolutionary phases: rise, main, and decay. The durations and characteristic timescales of these phases are much longer than a cooling time and indicate that the loop-averaged heating rate increases slowly, reaches a maintenance level, and then decreases slowly. This suggests that a single heating mechanism operates for the entire lifetime of the loop. For monolithic loops, the loop-averaged heating rate is the intrinsic energy release rate of the heating mechanism. For loops that are bundles of impulsively heated strands, it is an indication of the frequency of occurrence of individual heating events, or nanoflares. We show that the timescale of the loop-averaged heating rate is proportional to the timescale of ...
2006-01-01
Energy Technology Data Exchange (ETDEWEB)
The first 750 MW block of the new South Humber Bank gas-fired combined cycle power plant, sited about 300 km north from London, was officially commissioned in September 12th 1997. The project has been a major success story for Imatran Voima Oy (IVO), which developed the concept and managed the project and owns 22.5 % of the plant; and ABB Power Plants Limited, responsible for the turnkey delivery. IVO Generation Services (UK) is responsible for the running and maintenance of the facility. IVO also manages two other existing plants in Britain, at Brigg (240 MW) and Peterborough (360 MW)
1997-12-31
The first 750 MW block of the South Humber Bank gas-fired combined cycle power plant is commissioned
International Nuclear Information System (INIS)
The first 750 MW block of the new South Humber Bank gas-fired combined cycle power plant, sited about 300 km north from London, was officially commissioned in September 12th 1997. The project has been a major success story for Imatran Voima Oy (IVO), which developed the concept and managed the project and owns 22.5 % of the plant; and ABB Power Plants Limited, responsible for the turnkey delivery. IVO Generation Services (UK) is responsible for the running and maintenance of the facility. IVO also manages two other existing plants in Britain, at Brigg (240 MW) and Peterborough (360 MW).
The Chernobyl plant shutdown; L'arret de la centrale de Tchernobyl
Energy Technology Data Exchange (ETDEWEB)
The Chernobylsk-1 reactor, operational in september 1977 has been stopped in november 1996; the Chernobylsk-2 reactor started in november 1978 is out of order since 1991 following a fire. The Chernobylsk-3 reactor began in 1981. During the last three years it occurs several maintenance operations that stop it. In june 2000, the Ukrainian authorities decided to stop it definitively on the 15. of december (2000). This file handles the subject. it is divided in four chapters: the first one gives the general context of the plant shutdown, the second chapter studies the supporting projects to stop definitively the nuclear plant, the third chapter treats the question of the sarcophagus, and the fourth and final chapter studies the consequences of the accident and the contaminated territories. (N.C.)
2000-12-01
British Library Electronic Table of Contents (United Kingdom)
Background: Healthcare providers and their IT staff, working in an effort to balance appropriate accessibility with stricter security mandates, are considering the use of a single network sign-on approach for authentication and password management. Single sign-on (SSO) promises to improve usability of authentication for multiple-system users, increase compliance, and help curb system maintenance costs. However, complexities are introduced when SSO is placed within a collaborative environment. These complexities include unanticipated workflow implications that introduce greater security vulnerability for the individual user. Objectives and methodology: In this work, we examine the challenges of implementing a single sign-on authentication technology in a hospital environment. The aim of the...
2011-01-01
Statoil's Material Expectations for Pipelines
Energy Technology Data Exchange (ETDEWEB)
Pipelines are normally made in low-alloyed steels and the design is based on technical and economical criteria. For the transportation of corrosive fluids, a corrosion evaluation will determine what materials can be used. In the event that stainless steel must be used, investment costs will increase significantly. Use of life cycle cost evaluation may also apply, but we may question how often that is used properly. One must, furthermore, differ between onshore and offshore pipelines, because of differences in pipe laying conditions and in maintenance and repair costs. The consequences of a rupture may differ dramatically between onshore pipelines, too, i.e. a large gas pipeline in a populated area and a small oil pipeline in a nonpopulated area. (author)
2003-07-01
Sound climate installations. Gezonde klimaatinstallaties
Energy Technology Data Exchange (ETDEWEB)
An uncomfortable thermal climate, draft complaints and a bad airquality are often related to the climate installation. To avoid badfunctioning of the system a number of preconditions has to be fulfilledwith regard to design, planning and execution, adjustments, completion,control, maintenance and management of the installations. First threetypes of health problems in buildings are shortly discussed: buildingrelated illness, sick building syndrome and building or installationrelated complaints. Then some functions of the climate installationsare described: air filtration, filter classes and filter quality, aswell as investment costs for better filters. Next the causes for thecomplaints are dealt with: air conditioning, ventilation, air quality,and temperatures. Subsequently health affecting aspects in relation tothe climate systems are discussed: outdoor air pollution,microorganisms, bacteria (legionella pneumophila), allergies, ionneutralization and performance of ...
1989-10-01
Energy Technology Data Exchange (ETDEWEB)
Collectively, the organizations participating in the Site Operator Program have over forty years of EV experience and have operated electric vehicles (EVs) for over 600,000 miles, providing the most extensive EV operating and knowledge base in the country. The Site Operator Program is intended to provide financial and technical support and organizational resources to organizations active in the advancement of electric vehicles. Support is provided for the demonstration of vehicles and the test and evaluation of vehicles, components, and batteries. Support is also provided for the management and support of the program for the participating organizations. The Program provides a forum for participants to exchange information among the group, as well as with vehicle and equipment manufacturers and suppliers, and the public. A central data base at the Idaho National Engineering Laboratory provides a repository for-data on the vehicles being operated by the Program participants. Data ...
1991-01-01
Energy Technology Data Exchange (ETDEWEB)
Collectively, the organizations participating in the Site Operator Program have over forty years of EV experience and have operated electric vehicles (EVs) for over 600,000 miles, providing the most extensive EV operating and knowledge base in the country. The Site Operator Program is intended to provide financial and technical support and organizational resources to organizations active in the advancement of electric vehicles. Support is provided for the demonstration of vehicles and the test and evaluation of vehicles, components, and batteries. Support is also provided for the management and support of the program for the participating organizations. The Program provides a forum for participants to exchange information among the group, as well as with vehicle and equipment manufacturers and suppliers, and the public. A central data base at the Idaho National Engineering Laboratory provides a repository for-data on the vehicles being operated by the Program participants. Data ...
1991-12-31
Sexual function in women receiving maintenance dialysis
British Library Electronic Table of Contents (United Kingdom)
Abstract While substantial attention has been paid to the issue of sexual dysfunction in men on chronic dialysis, less is known about this problem in women with end-stage renal disease. We sought to assess sexual dysfunction in women on chronic dialysis and determine whether patients discuss this problem with their providers and receive treatment. We prospectively enrolled women receiving chronic hemodialysis or peritoneal dialysis in Pittsburgh, PA. We asked patients to complete the 19-item Female Sexual Function Index (FSFI) to assess sexual function and a 5-item survey that assessed whether patients had discussed sexual dysfunction with their providers and/or received treatment for this problem in the past. We enrolled 66 patients; 59 (89%) on hemodialysis and 7 (11%) on peritoneal dial...
2010-01-01
Sandwich belt high angle conveyors - applications in open pit mining
Energy Technology Data Exchange (ETDEWEB)
High angle conveyor (HAC) systems in open pit mining offer many advantages over the traditional, truck only, haulage systems, including: (1) superior energy efficiency, (2) less dependency on petroleum products, (3) less sensitivity to inflation, (4) less labor, (5) less excavation for the amount of ore recovered, and (6) less ramp construction and maintenance costs. Previous studies have revealed the technical and economic feasibility of high angle conveyors. The present paper introduces the Continental Conveyor sandwich belt HAC as the vital link to optimization of in-pit conveying systems. A test and demonstration unit, has been built and demonstrated. Discussion continues with the HAC systems to suit the various open pit mining operations and the corresponding characteristics of the system components, particularly the high angle conveyor. The range of HAC systems is discussed. (11 refs.)
1984-03-01
Safety considerations in the application of tension leg platforms and spar based systems
Energy Technology Data Exchange (ETDEWEB)
This paper is focused on TLP and Spar technology as applied to floating production applications. In particular, safety considerations as related to classification and certification requirements are addressed. This covers hull structures, marine systems, production facilities and the relevant mooring systems for each platform type from design approval on through construction, installation and ultimately the ongoing maintenance of the platform to acceptable standards throughout its operating life. The experience of the American Bureau of Shipping with these platforms will be utilized in supporting the practical application of classification and regulatory standards to ensure safe operations and concluding that use of such standards in conjunction with an experienced classification society provides a substantial benefit to companies utilizing these technologies. (author)
1998-07-01
Safety analysis of FFTF loss of flow without scram tests
International Nuclear Information System (INIS)
A program of tests were conducted in July 1986 at the Fast Flux Test Facility (FFTF) to demonstrate that the reactor could withstand a prototypic loss of flow (LOF) without scram without sustaining fuel damage. The reactor was taken to powers up to 50%, and the main primary coolant pump motors were tripped without scramming the control rods. This paper summarizes the analyses performed to demonstrate the maintenance of redundant protection for all design events as well as potential new events introduced by the test. The analyses focused on the following consequences: (1) unexpected test behavior; (2) transient overpower event during the test; and (3) LOF event during the test.
1987-06-07
SIMON Host Computer System requirements and recommendations
Energy Technology Data Exchange (ETDEWEB)
Development Service Order {number sign}90025 requested recommendations for computer hardware, operating systems, and software development utilities based on current and future SIMON software requirements. Since SIMON's main objective is to be dispatched on missions by an operator with little computer experience, user friendly'' hardware and software interfaces are required. Other design criteria include: a fluid software development environment, and hardware and operating systems with minimal maintenance requirements. Also, the hardware should be expandable; extra processor boards should be easily integrated into the existing system. And finally, the use of well established standards for hardware and software should be implemented where practical.
1990-11-29
Road maps on research and development plans for water chemistry of nuclear power systems
International Nuclear Information System (INIS)
Water chemistry of nuclear power plants has played an important role in reduction of personnel doses, structural materials and fuel integrity assurance, and reduction of radioactive wastes production. Further contributions are requested for advanced utilization of the LWR, advanced fuels and aging management of plants. Since water chemistry has an effect on all structure and materials immersed and at the same time affected by them, the optimum control not sticking to specific issues and covering the whole plant is required for these requests. Taking account of roles and activities of the industry, governmental institutes and academia, road maps on research and development plans for water chemistry were compiled into identified eleven items with targets and counter measures taken, such as common basic technologies, dose reduction, SCC mitigation, fuel cans corrosion/hydrogen absorption mitigation, condition based maintenance and flow accelerated corrosion ...
2008-05-01
Response to measles-mumps-rubella vaccine in children on dialysis.
Ten children receiving maintenance dialysis were immunized with the standard dose of measles-mumps-rubella vaccine between 15 and 33 months of age. Immune responses to vaccination were determined using commercially available enzyme-linked immunosorbent assays for measles, mumps, and rubella viruses. Eight children responded to measles vaccine, 5 to mumps vaccine, 8 to rubella vaccine, and only 3 children to all three vaccines, compared with a seroconversion rate of over 90% to all three vaccines in healthy children (P less than 0.0001). We contend that the relatively poor immunocompetence of our dialysis patients explains their less than optimal vaccine response and suggest that children vaccinated while undergoing dialysis be tested to confirm serological evidence of immunity. PMID:1571219
1992-03-01
Report documents O M at pumped-storage plants
Energy Technology Data Exchange (ETDEWEB)
The Electric Power Research Institute has published a report for planners, designers, owners, and operators of hydroelectric pumped-storage plants that records the operation and maintenance knowledge of 35 domestic and foreign pumped-storage projects. The report provides a comprehensive record of practices that have reduced forced outages and shortened scheduled repairs. As time passes and experienced staff retire at pumped-storage plants, many O M lessons are lost. To remedy that situation, EPRI commissioned Morrison-Knudsen Engineers Inc. to prepare a special report. The 348-page publication records the accumulated civil, geotechnical, mechanical, and electrical O M knowledge and experiences of pumped-storage plant staff. It also includes recommendations to planners and designers of future pumped-storage plants and concludes with descriptions of O M experiences reported by plant operators and utility representatives.
1991-12-01
Regulation of C-type natriuretic peptide expression
British Library Electronic Table of Contents (United Kingdom)
C-type natriuretic peptide (CNP) is a member of the small family of natriuretic peptides that also includes atrial natriuretic peptide (ANP) and brain, or B-type natriuretic peptide (BNP). Unlike them, it performs its major functions in an autocrine or paracrine manner. Those functions, mediated through binding to the membrane guanylyl cyclase natriuretic peptide receptor B (NPR-B), or by signaling through the non-enzyme natriuretic peptide receptor C (NPR-C), include the regulation of endochondral ossification, reproduction, nervous system development, and the maintenance of cardiovascular health. To date, the regulation of CNP gene expression has not received the attention that has been paid to regulation of the ANP and BNP genes. CNP expression in vitro is regulated by TGF-b and recepto...
2011-01-01
Reducing energy costs of plastics processing
Energy Technology Data Exchange (ETDEWEB)
Ways of reducing energy consumption in plastics processing are examined. Examples are given which illustrate how the awareness of everyone in the company to energy saving is essential with particular reference to switching arrangements to ensure such things as lights, machinery, compressed air systems are switched off when not needed or run at a lower level where appropriate. An understanding of the various elements of the electricity bill can inform a company`s planning of its operations to take advantage of lower tariffs. Machinery selection both with regard to efficiency of processing, quality of engineering and appropriate size can achieve significant savings and attention to maintenance is important. Fundamental to all aspects of energy saving is the monitoring of energy usage to identify where savings can be made and to evaluate the effectiveness of any measures taken. (UK)
1995-02-01
Recent strategy and progress in Korean nuclear PLIM program
International Nuclear Information System (INIS)
The strategy for the Korean nuclear power plant lifetime management (PLIM) program, which has been developed over the last 3 years, is introduced, together with descriptions of recent events and related maintenance activities. This leading Korean PLIM project has been focused on such areas as a plant data survey, screening and prioritization of systems, structures and components (SSCs), aging evaluation of major components, economic analysis and regulatory issues. The current status is outlined in terms of major tasks including aging evaluation of 13 major components. The future long-term plan which eventually aims at maximizing the economic benefit for both the utility and its customers is presented. Also described is the technical development required for plant life extension. (orig.).
1996-05-08
Recent Energy Saving Technologies on Railway Traction Systems
British Library Electronic Table of Contents (United Kingdom)
Energy saving technologies in the railway vehicle traction field can be mainly categorized into two domains: reducing loss and increasing the regenerative energy. Energy saving technologies for the traction equipment by the use of power converters with less loss and high-efficiency permanent magnet synchronous motors are introduced. The regenerative brake related technologies are also presented as another measure to save the energy, including the improvement of the regenerative brake control and application of energy storage devices. It is concluded that the benefit of the energy saving technology is not only the energy saving itself but also downsizing traction equipments and reducing the maintenance work in the electrical railway system. Copyright Copyright 2010 Institute of Electrical E...
2010-01-01
Quantitation of Cellular Dynamics in Growing Arabidopsis Roots with Light Sheet Microscopy
To understand dynamic developmental processes, living tissues must be imaged frequently and for extended periods of time. Root development is extensively studied at cellular resolution to understand basic mechanisms underlying pattern formation and maintenance in plants. Unfortunately, ensuring continuous specimen access, while preserving physiological conditions and preventing photo-damage, poses major barriers to measurements of cellular dynamics in indeterminately growing organs such as plant roots. We present a system that integrates optical sectioning through light sheet fluorescence microscopy with hydroponic culture that enables us to image at cellular resolution a vertically growing Arabidopsis root every few minutes and for several consecutive days. We describe novel automated routines to track the root tip as it grows, track cellular nuclei and identify cell divisions. We demonstrate the system's capabilities by collecting data on divisions and nuclear ...
2011-01-01
Pentobarbital anesthesia alters neural responses in the precedence effect
British Library Electronic Table of Contents (United Kingdom)
The precedence effect (PE) is thought to be beneficial for proper localization and perception of sounds. The majority of recent physiological studies focus on the neural discharges correlated with PE in the inferior colliculus (IC). Pentobarbital anesthesia is widely used in physiological studies. However, little is known of the effect of pentobarbital on the discharge of neurons in PE. Neuronal responses in the IC from 23 male SD rats were recorded by standard extracellular recording techniques following presentation of 4ms white noise bursts, presented from either or both of two loud speakers, at different interstimulus delays (ISDs). The neural responses were recorded for off-line analysis before or after intraperitoneal administration of pentobarbital at a loading or maintenance dose. ...
2011-01-01
Participative risk management in the construction of onshore pipelines
Energy Technology Data Exchange (ETDEWEB)
This paper described a risk control management tool that has been developed by Petrobras Petroleo, the largest Brazilian oil company and one of the world's leading oil companies. The system covers health, safety and environmental (HSE) issues regarding pipeline construction projects. The limitations of traditional safety management systems for coping with the critical problems related to environmental safety issues were discussed. In particular, this paper described how the HSE tool evaluates the risks resulting from the following aspects of onshore pipeline construction and assembly: establishing right-of-way and route locations, transporting pipe, developing the construction site, opening the trench, pipe laying, pipe bending, concrete external coating, welding, external anticorrosive coatings, pipe placement backfilling, hydrostatic testing, maintenance operations, and pipeline commissioning. 6 refs., 1 tab.
2000-07-01
Energy Technology Data Exchange (ETDEWEB)
Since August 1984, the MITRE Corporation has been supporting the Naval Sea Systems Command (NAVSEA) and the Naval Medical Command (NAVMEDCOM) in their joint efforts to enhance the Navy Occupational Health Information Management System (NOHIMS). The goal of the enhancement effort was to create a comprehensive occupational health and safety system for Navy industrial facilities by expanding upon the original NOHIMS functions and adding modules for hazard deficiency abatement, hazardous-material control, injury claims and compensation, and safety and health training. To meet this goal, MITRE developed an enhanced industrial subsystem, referred to as the Occupational Safety and Health Record Keeping System (OSHRKS), using a prototyping approach and a public-domain data base-management software package, the Veterans Administration's (VA's) FileManager (FileMan).
1987-06-01
Mobile offshore drilling rig newbuild and replacement cost functions
British Library Electronic Table of Contents (United Kingdom)
Mobile offshore drilling rigs are used to drill, complete and workover wellbores in marine environments. The fleet that exists today consists of a wide variety of vessels built to various specifications over the past three decades, and because they operate in harsh, corrosive environments, they wear out structurally and require periodic maintenance. Rig designs have evolved with changes in operating requirements and new technology and rigs are frequently modified and upgraded, depending upon market conditions, operator preferences and other factors. The construction and replacement costs of offshore rigs are often used for management planning, financial valuation and insurance analysis, and because of the wide variety of designs, specifications and upgrades, cost estimates vary widely. In ...
2010-01-01
British Library Electronic Table of Contents (United Kingdom)
During the first few years of elevated atmospheric [CO2] treatment at the Nevada Desert FACE Facility, photosynthetic downregulation was observed in desert shrubs grown under elevated [CO2], especially under relatively wet environmental conditions. Nonetheless, those plants maintained increased A sat (photosynthetic performance at saturating light and treatment [CO2]) under wet conditions, but to a much lesser extent under dry conditions. To determine if plants continued to downregulate during long-term exposure to elevated [CO2], responses of photosynthesis to elevated [CO2] were examined in two dominant Mojave Desert shrubs, the evergreen Larrea tridentata and the drought-deciduous Ambrosia dumosa, during the eighth full growing season of elevated [CO2] treatment at the NDFF. A comprehen...
2011-01-01
Lessons learned from accidents in industrial radiography
International Nuclear Information System (INIS)
Industrial radiography accounts for approximately half of all the reported accidents for the nuclear related industry, in both developed and developing countries. This Safety Report is the result of a review made of a large selection of accidents in industrial radiography reported by regulatory authorities, professional associations and scientific journals. A small, representative selection of 43 accident descriptions has been used to illustrate the primary causes of radiography accidents, and a set of measures provided to prevent the recurrence of such accidents or to mitigate the consequences of those that do occur. These accident descriptions were categorized by primary causes as follows: inadequate regulatory control; failure to follow operational procedures; inadequate training; inadequate maintenance; human error; equipment malfunction or defect; design flaws; and wilful violation. The information in this Safety report is intended for use by those regulatory ...
Isotope labeling strategies for NMR studies of RNA
Energy Technology Data Exchange (ETDEWEB)
The known biological functions of RNA have expanded in recent years and now include gene regulation, maintenance of sub-cellular structure, and catalysis, in addition to propagation of genetic information. As for proteins, RNA function is tightly correlated with structure. Unlike proteins, structural information for larger, biologically functional RNAs is relatively limited. NMR signal degeneracy, relaxation problems, and a paucity of long-range {sup 1}H-{sup 1}H dipolar contacts have limited the utility of traditional NMR approaches. Selective isotope labeling, including nucleotide-specific and segmental labeling strategies, may provide the best opportunities for obtaining structural information by NMR. Here we review methods that have been developed for preparing and purifying isotopically labeled RNAs, as well as NMR strategies that have been employed for signal assignment and structure determination.
2010-01-15
Ionizing radiation is a potent inducer of mitotic recombination in mouse embryonic stem cells
British Library Electronic Table of Contents (United Kingdom)
Maintenance of genomic integrity in embryonic cells is pivotal to proper embryogenesis, organogenesis and to the continuity of species. Cultured mouse embryonic stem cells (mESCs), a model for early embryonic cells, differ from cultured somatic cells in their capacity to remodel chromatin, in their repertoire of DNA repair enzymes, and in the regulation of cell cycle checkpoints. Using 129XC3HF1 mESCs heterozygous for Aprt, we characterized loss of Aprt heterozygosity after exposure to ionizing radiation. We report here that the frequency of loss of heterozygosity mutants in mESCs can be induced several hundred-fold by exposure to 5-10Gy of X-rays. This induction is 50-100-fold higher than the induction reported for mouse adult or embryonic fibroblasts. The primary mechanism underlying the...
2011-01-01
Involvement of Rh blood group polypeptides in the maintenance of aminophospholipid asymmetry
International Nuclear Information System (INIS)
The human erythrocyte (RBC) Rh blood group system consists of a complex of distinct integral membrane polypeptides with physical properties common to the aminophospholipid transporter responsible for the transbilayer movement of phosphatidylserine (PS) in RBC. To assess the involvement of Rh polypeptides in PS translocation, the aminophospholipid translocase was labeled with a photoactivatable PS analogue, "1"2"5I-azido-PS, and with an inhibitor of PS transport, "1"2"5I-labeled 2-(2-pyridyldithio)ethylamine. The ability of monoclonal Rh antibodies to immunoprecipitate the labeled transporter was determined. Immunoprecipitated Rh polypeptides were found to be labeled with the aminophospholipid translocase markers, suggesting that Rh proteins are involved in the transbilayer movement of PS.
Insights gained from studies of gas pipeline rights-of-way of varying ages through wetlands
Energy Technology Data Exchange (ETDEWEB)
Impacts of gas pipeline rights-of-way (ROWs) through wetlands depend on types of habitat, construction techniques, final elevations, ROW maintenance practices, soil composition, and local climate. In some instances factors unrelated to the presence of the pipeline may have greater impacts on wetland modification than does the pipeline itself. At one site, the required seeding program inhibited natural reestablishment of wetland plants; at another, downstream construction resulted in a major disruption to the adjacent wetland habitat. This paper discusses observation from 13 study sites, each zero to 30 years old, that are located in seven Eastern States.
1993-10-01
Induction motor for tunnel exhauster; Tunnel haifukiyo yudo dendoki
Energy Technology Data Exchange (ETDEWEB)
A totally-enclosed, fan-cooled, rib-cooled type induction motor is adopted for an exhauster which is to be installed in a ventilation station for dust catcher in a tunnel. It has the highest capacity in Japan for the above purpose, and is provided with a cooling fan inside to recirculate cooled air, thereby improving cooling efficiency and reducing size and weight. Three-row combined angular ball bearings are used as the thrust bearings, and grease lubrication system is adopted to simplify the inspection/maintenance works. It is to be delivered to Japan Highway Public Corporation's Shizuoka Construction Bureau, Yaizu site office. Its electric specifications are 455 kW, 440 V, 890 A and 510 rpm, and its mechanical specifications are thrust load: 16 kN and impeller load: 7.2 kN. (translated by NEDO)
2000-01-10
Incorporation of organizational failures in PSA
International Nuclear Information System (INIS)
A large portion of the work performed at nuclear power plants follows standardized flow paths. For example, although components on which the maintenance crew works differ from one assignment to the next, all assignments basically follow the same process: requesting, reviewing, planning, scheduling, executing, testing, and documenting the work. In general, the term open-quotes work processclose quotes is used to refer to a standardized sequence of tasks designed within the operational environment of an organization to achieve a specific goal. The predictable nature of work processes suggests that a systematic analysis can be conducted to identify the desirable design of the process and to develop performance measures with respect to the strengths and weaknesses in the process. Furthermore, because of the close relationship of the work process to plant performance and plant safety, it is believed that such an analysis will facilitate the inclusion of organizational ...
1993-06-20
International Nuclear Information System (INIS)
Liquid radioactive waste treatment method of using evaporator was widely used from Kori 1 to Uljin 3 and 4, but a liquid radioactive waste treatment equipment that uses an ion exchange method instead of an evaporator was adopted aiming to minimize amount of radioactive waste and radiation exposure. However, the same equipment was introduced and applied for the first time in Korea and had experienced difficulties in securing credibility for the equipment and handling of liquid radioactive waste with inadequate data about performance and experience in operation and maintenance. In this study, examination, application and effect analysis was performed on the optimization measure for handling liquid radioactive waste of Yonggwang Nuclear Power Unit 5 and 6(YGN 5 and 6) that applies an ion exchange method
2010-10-01
Hepatitis B and C in dialysis units in Iran: Changing the epidemiology
British Library Electronic Table of Contents (United Kingdom)
Abstract Hepatitis B (HBV) and C (HCV) viruses are the most important infections transmitted by the parenteral route in patients receiving maintenance dialysis. The prevalence varies markedly from country to country. The aim of this study is to review the efficacy of the strategies to reduce the incidence of these infections and the trend of results in Iran. As a routine, all hemodialysis patients in Iran have biannual blood samples for assessment of serum HBSAg, HBS Abs, and HCV Abs. The data are collected in the Ministry of Health. For statistical analysis, prevalence, and incidence were calculated. There is an increasing prevalence/incidence of end-stage renal disease (ESRD) in Iran, from 238/49.9 pmp in 2000 to 357/63.8 pmp in 2006. The prevalence of positive HBSAg and HCV Abs decrease...
2008-01-01
Heber Geothermal Binary Demonstration Project. Final design availability assessment. Revision 1
Energy Technology Data Exchange (ETDEWEB)
An availability assessment of the principal systems of the Heber Geothermal Power Plant has been carried out based on the final issue of the process descriptions, process flow diagrams, and the approved for design P and IDs prepared by Fluor Power Services, Inc. (FPS). The principal systems are those which contribute most to plant unavailability. The plant equivalent availability, considering forced and deferred corrective maintenance outages, was computed using a 91 state Markov model to represent the 29 principal system failure configurations and their significant combinations. The failure configurations and associated failure and repair rates were defined from system/subsystem availability assessments that were conducted using the availability assessments based on the EPRI GO methodology and availability block diagram models. The availability and unavailability ranking of the systems and major equipment is presented.
1983-02-01
International Nuclear Information System (INIS)
Presented in this report are the quantitative and qualitative aspects of the more than 5,800 applications of Grafoil on-plant. The subject all-graphite product was originally made by the Union Carbide Corporation. Its utilization in the forms of valve packing, gasketing and sealant tapes for leak repair and prevention on-plant since March 1970 is marked with typical zero-leak results. For all practical purposes, the successful results with Grafoil implementation indicate an unqualified control of leakage problems that began in 1967 with the V-11 and V-12 valves in the primary system of N Reactor. Meaningfully, the accruals of savings with existing and future applications shall continue to be incalculable in personnel exposure, maintenance, and capital. Inherent in the savings are the devised methodology and innovative developments coordinately employed in resolving the leak repair problems.
Glance Information System for ATLAS Management
ATLAS Experiment is an international collaboration where more than 37 countries, 172 institutes and laboratories, 2900 physicists, engineers, and computer scientists plus 700 students participate. The management of this teamwork involves several aspects such as institute contribution, employment records, members' appointment, authors' list, preparation and publication of papers and speakers nomination. Previously, most of the information was accessible by a limited group of people and the system used was not designed to handle new requirements easily. Moreover, developers had to face problems such as different terminology, diverse data modeling, heterogeneous databases and unlike users needs. Besides that, the maintenance has to be an easy task considering the long lifetime experiment and professionals turnover. The Glance system, a generic mechanism for accessing any database, acts as an intermediate layer isolating the user from the particularities of each ...
2011-01-01
Gas Research Institute wetland research program
Energy Technology Data Exchange (ETDEWEB)
As part of three ongoing research projects, the Gas Research Institute (GRI) is studying the natural gas industry`s impacts on wetlands and how to manage operations so that impacts can be minimized or eliminated. The objective of the first project is to gain a better understanding of the causes and processes of wetland loss in the Louisiana deltaic plain and what role gas pipeline canals play in wetland loss. On the basis of information gathered from the first projects, management and mitigation implications for pipeline construction and maintenance will be evaluated. The objective of the second project is to assess the floral and faunal communities on existing rights-of-way (ROWs) that pass through numerous types of wetlands across the United States. The emphasis of the project is on pipelines that were installed within the past five years. The objective of the third project is to evaluate the administrative, jurisdictional, technical, and economic issues of ...
1992-12-01
Future directions in controlling the LAMPF-PSR Accelerator Complex at Los Alamos National Laboratory
Energy Technology Data Exchange (ETDEWEB)
Four interrelated projects are underway whose purpose is to migrate the LAMPF-PSR Accelerator Complex control systems to a system with a common set of hardware and software components. Project goals address problems in performance, maintenance and growth potential. Front-end hardware, operator interface hardware and software, computer systems, network systems and data system software are being simultaneously upgraded as part of these efforts. The efforts are being coordinated to provide for a smooth and timely migration to a client-sever model-based data acquisition and control system. An increased use of the distributed intelligence at both the front-end and operator interface is a key element of the projects. 2 refs., 2 figs.
1991-01-01
Five years operating experience at the Fast Flux Test Facility
Energy Technology Data Exchange (ETDEWEB)
The Fast Flux Test Facility (FFTF) is a 400 Mw(t), loop-type, sodium-cooled, fast neutron reactor. It is operated by the Westinghouse Hanford Company for the United States Department of Energy at Richland, Washington. The FFTF is a multipurpose test reactor used to irradiate fuels and materials for programs such as Liquid Metal Reactor (LMR) research, fusion research, space power systems, isotope production and international research. FFTF is also used for testing concepts to be used in Advanced Reactors which will be designed to maximize passive safety features and not require complex shutdown systems to assure safe shutdown and heat removal. The FFTF also provides experience in the operation and maintenance of a reactor having prototypic components and systems typical of large LMR (LMFBR) power plants. The 5 year operational performance of the FFTF reactor is discussed in this report. 6 refs., 10 figs., 2 tabs.
1987-04-01
Five years operating experience at the Fast Flux Test Facility
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF) is a 400 Mw(t), loop-type, sodium-cooled, fast neutron reactor. It is operated by the Westinghouse Hanford Company for the United States Department of Energy at Richland, Washington. The FFTF is a multipurpose test reactor used to irradiate fuels and materials for programs such as Liquid Metal Reactor (LMR) research, fusion research, space power systems, isotope production and international research. FFTF is also used for testing concepts to be used in Advanced Reactors which will be designed to maximize passive safety features and not require complex shutdown systems to assure safe shutdown and heat removal. The FFTF also provides experience in the operation and maintenance of a reactor having prototypic components and systems typical of large LMR (LMFBR) power plants. The 5 year operational performance of the FFTF reactor is discussed in this report. 6 refs., 10 figs., 2 tabs.
1987-09-13
Energy Technology Data Exchange (ETDEWEB)
The transmission of electrical energy by use of underground cables is increasing. Fault location techniques have certain limitations; incipient fault detection and location would help reduce the maintenance cost of these lines as well as improve the reliability of service. The report discusses some test results related to RF-probing techniques applied to high-voltage transmission lines. The high-frequency losses and attenuation in high-voltage cables places certain ultimate limitations on RF-probing techniques for incipient fault detection. Time-domain reflectrometry methods were employed to assess the RF-transmission properties of high-voltage cables at frequencies as high as 6 GHz. Fast-Fourier-transform deconvolution was used to obtain loss measurements as a function of frequency. The loss mechanisms were identified. The measurement hardware and methods are discussed as well as analysis approach leading to the conclusions.
1986-04-01
International Nuclear Information System (INIS)
This document contains a summarization of the results and insights from the Level 1 accident sequence analyses of internally initiated events, internally initiated fire and flood events, seismically initiated events, and the Level 2/3 risk analysis of internally initiated events (excluding fire and flood) for Surry, Unit 1. The analysis was confined to mid-loop operation, which can occur during three plant operational states (identified as POSs R6 and R10 during a refueling outage, and POS D6 during drained maintenance). The report summarizes the Level 1 information contained in Volumes 2--5 and the Level 2/3 information contained in Volume 6 of NUREG/CR-6144.
1990-10-22
Evaluating coal processing technology for the Indian power industry
Energy Technology Data Exchange (ETDEWEB)
Due to the ever-increasing demand for electric power in India, the production of steam (non-coking) coal will continuously increase. Since most Indian coals contain high ash-forming minerals which result in the increased costs of transportation, boiler maintenance and refuse handling, the use of pre-combustion washing becomes a viable concept. However, many professionals in the Indian mining industry have debated on which of the many benefication techniques is the most appropriate for the pre-combustion cleaning. Through the comprehensive study presented herein, it is found that heavy media separation is more suitable than the jig process for most of the Indian coals. A discussion and flowsheet for the state-of-the-art plant design called the High Capacity Processor (HCP) using advanced coal cleaning techniques are presented.
1996-12-31
Environmental hazards for pipelines in coastal regions/shore approaches
Energy Technology Data Exchange (ETDEWEB)
Often oil/gas and other hydrocarbons discovered and produced offshore are transported to onshore facilities via submarine pipelines. The route of such pipelines traverses through coastal/shore approach regions. For a rational/economic design, safe installation and subsequent operation it is of utmost importance to review, evaluate and finalize various environmental hazard such as winds, waves, currents, seabed topography, seabed and sub-bottom soils, seabed erosion and soil accretion. This paper addresses the above described environmental hazards, their assessment and techniques to prepare design parameters which must be used for stability analysis, installation methods, long term operation and maintenance for the shore approaches. Additionally, various proven pipeline installation and stabilization techniques for the shore approach region are detailed. As case histories, three approaches installed in the Dutch North Sea are described.
1995-12-31
Endoscopic monitoring of infliximab therapy in Crohn's disease
British Library Electronic Table of Contents (United Kingdom)
AbstractBackground: So far, infliximab (IFX) therapy for the treatment of Crohn's disease (CD) has generally been guided by clinical symptoms. Data on treatment response as ascertained by endoscopy in IFX therapy are scarce. The aims of this study were to measure the endoscopic response rate during IFX induction and maintenance therapy in luminal CD, and also evaluate the role of endoscopy in monitoring IFX therapy. Methods: Data obtained from 71 patients with active luminal CD and treated with IFX were analyzed retrospectively. The endoscopy findings were scored according to mucosal activity as: 0 (remission), 1-2 (mild), 3-4 (moderate), and 5-6 (severe). A positive endoscopic response was determined by a decrease in score of at least two points and mucosal healing was assigned a score of...
2011-01-01
Economic comparison of clean coal generating technologies with natural gas-combined cycle systems
International Nuclear Information System (INIS)
This paper reports that there are four combustion technologies upon which U.S. electric utilities are expected to rely for the majority of their future power generating needs. These technologies are pulverized coal- fired combustion (PC); coal-fired fluidized bed combustion (AFBC); coal gasification, combined cycle systems (CGCC); and natural gas-fired combined cycle systems (NGCC). The engineering and economic parameters which affect the choice of a technology include capital costs, operating and maintenance costs, fuel costs, construction schedule, process risk, environmental and site impacts, fuel efficiency and flexibility, plant availability, capacity factors, timing of startup, and the importance of utility economic and financial factors.
1990-04-23
Energy Technology Data Exchange (ETDEWEB)
A UPS based on a line-interactive system for CATV (Cable TV) networks has been newly developed. An inverter of the UPS featuring a pure sine wave output and equipped with an uninterrupptible transfer switch made it possible to raise its reliability high and to reduce the uninterruptible transfer time from 50 {approx} 100 ms to only 3 ms. The expected life of 15 years and maintenance-free of the UPS were realized by monitoring and optimizing the operational conditions of lead-acid batteries, aluminum electrolytic capacitors and cooling fans. The use of rust- and weather- resistant painting methods for an outer box of the UPS also contributed to extend the life of the system. (author)
1998-12-25
Development of technology on the material surveillance of CANDU pressure tubes
International Nuclear Information System (INIS)
Material degradation of pressure tubes, which are the most important components in CANDU fuel channel, can only be evaluated by removing and examining them(material surveillance). This study aimed at establishment of overall evaluation technology including the evaluation of the material degradation for the integrity of pressure tubes of Wolsung units. Material tests for pressure tubes were performed as follows; (1) Evaluation on life limiting factors of pressure tubes (2) Review on leak-before-break and integrity maintenance technology of pressure tubes (3) Survey on selection criteria for tubes to be inspected and on related regulations for material surveillance (4) Analysis of material surveillance test procedure (5) Basic examinations of Wolsung unit 1 pressure tube material(TEM, texture, chemical component etc) (6) Manufacture of test equipments and test (DHCV, hydriding, grip and tensile specimen etc). 23 figs, 6 tabs, 59 refs. (Author).
1997-05-21
Developing defined culture systems for human pluripotent stem cells
British Library Electronic Table of Contents (United Kingdom)
Human pluripotent stem cells hold promising potential in many therapeutics applications including regenerative medicine and drug discovery. Over the past three decades, embryonic stem cell research has illustrated that embryonic stem cells possess two important and distinct properties: the ability to continuously self-renew and the ability to differentiate into all specialized cell types. In this article, we will discuss the continuing evolution of human pluripotent stem cell culture by examining requirements needed for the maintenance of self-renewal in vitro. We will also elaborate on the future direction of the field toward generating a robust and completely defined culture system, which has brought forth collaborations amongst biologists and engineers. As human pluripotent stem cell re...
2011-01-01
Destructive spondyloarthropathy in hemodialysis patients. Report of four cases and prospective study
Energy Technology Data Exchange (ETDEWEB)
A destructive spondyloarthropathy is reported in four patients undergoing maintenance hemodialysis for chronic renal disease. In a separate investigation a controlled, prospective radiographic study of the cervical spine revealed this spondyloarthropathy in 4 (15%) of 26 long-term dialysis patients. A single disk level was involved in three patients, and two disc levels were involved in one patient. This spondyloarthropathy correlated with the duration of dialysis but not with the radiographic evidence of renal osteodystrophy or severity of laboratory abnormalities associated with hyperparathyroidism. Three of these four patients also had discovertebral erosions or destruction involving the lumbar spine. Cervical spine flexion views revealed evidence of ligamentous laxity or instability in three (12%) dialysis patients, all with vertebral resorption and disc space narrowing. It is postulated that this instability may contribute to the development of cervical ...
1988-04-01
Design of sediment-control measures for small areas in surface coal mining. Draft report
Energy Technology Data Exchange (ETDEWEB)
The manual provides design information for four groups of sediment control structures and treatments which are suitable for use on small areas in surface coal mining. A detailed design procedure is given for each group which will estimate the total amount of settleable solids from a small area with a sediment control structure or treatment for a specific design storm. A procedure is also given for estimating the mean annual sediment yield from a small area. Information on design, installation, maintenance and cost is given for each sediment control measure. Methods for determining the maximum allowable area for each sediment control measure and for design of combined sediment control systems are presented. The design procedures contain numerous nomographs, graphs, and worksheets to facilitate the use of the design procedure. The sediment control measures, design procedures, and materials in the manual are applicable to coal-bearing regions of the continental United ...
1982-04-01
Design of sediment-control measures for small areas in surface coal mining
Energy Technology Data Exchange (ETDEWEB)
The manual provides design information for four groups of sediment control structures and treatments which are suitable for use on small areas in surface coal mining. A detailed design procedure is given for each group which will estimate the total amount of settleable solids from a small area with a sediment control structure or treatment for a specific design storm. A procedure is also given for estimating the mean annual sediment yield from a small area. Information on design, installation, maintenance and cost is given for each sediment control measure. Methods for determining the maximum allowable area for each sediment control measure and for design of combined sediment control systems are presented. The design procedures contain numerous nomographs, graphs, and worksheets to facilitate the use of the design procedure. The sediment control measures, design procedures, and materials in the manual are applicable to coal bearing regions of the continental Unted ...
1982-08-01
Energy Technology Data Exchange (ETDEWEB)
The development and installation, by Hydro-Quebec, of a computerized pressure monitoring and control system on its fluid-filled high voltage underground cable network in Montreal, was described. The average age of these underground fluid-filled cables is more than 30 years and the cost to replace the circuits is estimated to be 230 million dollars. It is, therefore, crucial to maintain at all times and under all operating conditions a positive oil pressure in order to maintain the dielectric strength of paper insulation, and to prevent air and moisture from entering the cables and accessories. The monitoring and control system is reliable, flexible, user friendly and easy to upgrade. It reduces intervention time on the cables and ensures the protection of the cable network by remotely operating valves to connect oil reserve banks and by providing efficient maintenance management tools. 1 ref., 1 tab., 4 figs.
1996-08-01
British Library Electronic Table of Contents (United Kingdom)
In the Lower Rio Grande Valley (LRGV) of Texas, cotton regrows and produces fruit from undestroyed stalks throughout the winter, and in spring weevils from such locations become a serious threat. The success of the boll weevil eradication program, which was reintroduced in the LRGV in 2005, will be dependent on thorough stalk destruction following harvest. However, adverse weather conditions and conservation tillage often impede immediate and complete stalk destruction using typical tool implements, and alternative stalk control methods are needed. This study provides an examination of the efficacy for cotton stalk destruction of different herbicides (thifensulfuron-methyl + tribenuron-methyl, dicamba-diolamine, 2,4-D-dimethylammonium, flumioxazin, 2,4-DB-dimethylammonium and carfentrazone...
2007-01-01
British Library Electronic Table of Contents (United Kingdom)
Air toxics from the industrial wastewater treatment plants (IWTPs) impose serious health concerns on its surrounding residential neighborhoods. To address such health concerns, one of the key challenges is to quantify the air emissions from the IWTPs. The objective here is to characterize the air emissions from the IWTPs and quantify its associated uncertainty. An IWTP receiving the wastewaters from an airplane maintenance facility is used for illustration with focus on the quantification of air emissions for benzyl alcohol, phenol, methylene chloride, 2-butanone, and acetone. Two general fate models, i.e., WATER9 and TOXCHEM+V3.0 were used to model the IWTP and quantify the air emissions. Monte Carlo and Bootstrap simulation were used for uncertainty analysis. On average, air emissions fr...
2010-01-01
Radiation protection of the personnel who will perform interventions in the LHC Beam Cleaning Insertions is mandatory and includes the design of equipment and the establishment of work procedures. Residual dose rates due to activated equipment are expected to reach significant values such that any maintenance has to be planned and optimized in advance. Three-dimensional maps of dose equivalent rates at different cooling times after operation of the LHC have been calculated with FLUKA. The simulations are based on an explicit calculation of induced radioactivity and of the transport of the radiation from the radioactive decay. The paper summarizes the results for the Beam Cleaning Insertions and discusses the estimation of individual and collective doses received by personnel during critical interventions, such as the exchange of a collimator or the installation of Phase 2. The given examples outline the potential and the need to optimize, in an iterative way, the ...
2005-01-01
Energy Technology Data Exchange (ETDEWEB)
This paper discusses how specialized techniques for machine condition monitoring can help to eliminate false alarms and undetected faults, leading to a truly cost effective predictive maintenance program. It is vital to base the monitoring system on the parameter which will give the most useful information about potential faults and breakdowns. This parameter is generally agreed to be vibration. While oil debris analysis and variations in temperature, geometry and machine speed can all give advance warning of faults, no other parameter can reveal as wide a range of fault types as vibration. The vibration transducers job is to accurately and faithfully convert the vibration into an electric signal for assessment. If this part of the system is weak, reliability will be badly affected. Data integrity is crucial.
1990-07-01
Energy Technology Data Exchange (ETDEWEB)
Both the KRW fluidized-bed gasifier and the transport gasifier case studies were used for this assessment. The transport technology is a high-velocity circulating fluidized-bed reactor currently under development by The M.W. Kellogg Company. In the earlier assessment, seven design concepts or cases were identified; a process design was developed; major equipment items were identified; estimates of capital cost, operation and maintenance cost, and cost of electricity were developed; reliability was predicted; and development issues were identified for six studies. Three of the most probable cases were further evaluated for a Greenfield assessment in this report to adequately determine all costs independent of facilities at Plant Wansley.
1991-12-01
Energy Technology Data Exchange (ETDEWEB)
Both the KRW fluidized-bed gasifier and the transport gasifier case studies were used for this assessment. The transport technology is a high-velocity circulating fluidized-bed reactor currently under development by The M.W. Kellogg Company. In the earlier assessment, seven design concepts or cases were identified; a process design was developed; major equipment items were identified; estimates of capital cost, operation and maintenance cost, and cost of electricity were developed; reliability was predicted; and development issues were identified for six studies. Three of the most probable cases were further evaluated for a Greenfield assessment in this report to adequately determine all costs independent of facilities at Plant Wansley.
1991-12-01
Application of leak-before-break approach to PWR piping designed by Babcock and Wilcox: Final report
Energy Technology Data Exchange (ETDEWEB)
Recently, the leak-before-break (LBB) concept has been used successfully to eliminate some pipe whip restraints, snubbers and jet impingement shields from the primary reactor cooling system piping of pressurized water reactors. This has resulted in substantial savings in maintenance costs, reductions in radiation exposure of plant service personnel, and has enhanced the overall safety of nuclear power plants. This study provides guidelines to utilities in expanding the application of the LBB concept to additional pipe systems and it couples the concept with hardware optimization. Seven high energy piping systems were investigated for technical feasibility in using the LBB concept. The results indicate that some of these seven lines are good candidates for the leak-before-break application.
1987-01-01
Application of Risk Management for Control and Monitoring Systems
This paper presents an application of the state of the art and new trends for risk management of safety-related control and monitoring systems, currently applied in the industry. These techniques not only enable to manage safety and reliability issues but they also help in the control of quality and economic factors affected by the availability and maintenance of the system. The method includes an unambiguous definition of the system in terms of functions and a systematic analysis of hazardous situations, undesired events and possible malfunctions. It also includes the identification and quantification of the risk associated to the system. The required risk reduction is specified in terms of safety integrity levels. The safety integrity level results in requirements, preventive measures, possible improvements and recommendations to assure the satisfactory management of the risk.
2001-01-01
With the rapid growth of Information and Communication Technology, Electronic commerce is now acting as a new means of carrying out business transactions through electronic means such as Internet environment. To avoid the complexities associated with the digital cash and electronic cash, consumers and vendors are looking for credit card payments on the Internet as one possible time-tested alternative. This gave rise of the on-line payment processing using a third-party verification; which is not suitable for the developing countries in most of the cases because of the excessive costs associated with it for maintenance and establishment of an online third-party processor. As a remedy of this problem, in this paper, we have proposed a framework for easy security incorporation in credit card based electronic payment system without the use of an on-line third- party processor; which tends to be low cost and effective for the developing countries.
2006-01-01
Alternative cycles based on carbon dioxide for central receiver solar power plants
British Library Electronic Table of Contents (United Kingdom)
Research in concentrated thermal solar power plants of all types and, in particular, those based on central receiver, namely solar tower plants, has experienced great impetus in the last decade, reaching full commercial operation with the PS10 plant in Spain. In spite of previous demonstration plants testing different receivers and power cycle layouts, this first commercial power plant adopted a cavity receiver generating saturated steam and therefore penalising cycle efficiency in order to gain plant reliability. According to the experience gained, if a competitive Levelised Cost of Electricity is to be reached, capital and maintenance costs must be reduced and efficiencies must be increased. To achieve these goals, modifying the power cycle is deemed essential, whether using superheated ...
2011-01-01
The goal of this project is to demonstrate that, by combining state-of-the-art technology, highly efficient plant operation and maintenance capabilities and by-product gypsum sales, significant reductions of SO{sub 2} emissions can be achieved at approximately one-half the life cycle cost of a conventional Flue Gas Desulfurization (FGD) system. Further, this emission reduction is achieved without generating solid waste and while minimizing liquid wastewater effluent. Basically, this project entails the design, construction and operation of a nominal 600 MWe AFGD facility to remove SO{sub 2} from coal-fired power plant flue gas at the Northern Indiana Public Service Company`s Bailly Generating Station.
1994-08-01
A vortex valve ejector combination for fluidic two diode pumps
International Nuclear Information System (INIS)
Fluidic two diode pumps have been developed for moving highly toxic and for radioactive waste liquors about chemical plant. The pumps have a cylinder into which liquor is initially sucked and then expelled. For situations where no maintenance can be carried out the need has arisen for a fluidic alternator to the solenoid ejector system used on top of the pump cylinder to supply an alternating negative/positive air supply. A fluidic air alternator has been constructed by modifying a small vortex amplifier and inserting an ejector opposite to the throat of the outlet diffuser. The vortex valve ejector is described and performance characteristics are presented. Several developments of the V.V.E. for fluidic pumping and other applications are also reported. (author).
A six-axes robot for deep water applications
Energy Technology Data Exchange (ETDEWEB)
The six-axes industrial robot MANUTEC r15 UW was modified to work underwater and successfully tested down to the simulated water depth of 1100 m. Next step in the program was to use this robot as a handling tool for inspection tasks at the welding seam of an underwater structure conducted with CCD-cameras and distance sensors. This was also to demonstrate the possibility to assist and later on to replace divers from this work. Additional research was focussed on the stiffness and rigidity of the robot during the precise guiding of tools and workpieces under current water conditions up to a flow velocity of 1.1 m/s. Present work is concentrated on the application of this subsea robot on a maintenance task at the Brazilian underwater template OCTOS-1000. For this experiments the robot is integrated in a large mock-up which simulates a quarter section of this template. (orig.)
1994-01-01
A novel gamma scanning system for on-line diagnostic inspection of industrial process columns
International Nuclear Information System (INIS)
A computerised gamma scanning facilities for on-line investigation of industrial process columns and vessels has been developed by the Malaysian Nuclear Agency (Nuclear Malaysia). The technology, based on the principle of gamma-ray absorption, has been successfully applied for real-time troubleshooting, process investigation and predictive maintenance of a number of distillation columns and process vessels in petroleum refineries, gas processing plants and chemical plants in the country and the surrounding region. This paper outlines basic characteristics of the system and describes the inspection procedures, and in addition, presents a number of case studies. The case studies are purposely chosen to illustrate the versatility of the technology, and furthermore to demonstrate the economic benefits which can be realised from the application of this technology. (Author)
A Study on the Construction Plan for Vibration Analysis System of HANARO Rotating Machinery
Energy Technology Data Exchange (ETDEWEB)
The objective of this study is to establish a construction plan for vibration analysis system of HANARO's rotating machinery. To achieve this purpose, as a first step, the references related to the vibration analysis system for the rotating machinery were investigated. In addition, to verify the possibility of condition monitoring of the pumps, vibration signals obtained from the vibration monitoring system were analyzed. The results show that using the accelerometers mounted on the bearing locations of the pumps can monitor the current status of the pump such as unbalance, misalignment, and bearing condition. Based on the results of this study, the construction plans for the vibration analysis system of HANARO have been established. The hardware of the vibration analysis system will be installed by the end of this year. It is expected that the developed vibration analysis system can be utilized for the realization of the preventive maintenance of the ...
2005-10-15
A Bayesian approach to analyze energy balance data from lactating dairy cows
British Library Electronic Table of Contents (United Kingdom)
The objective of the present investigation was to develop a Bayesian framework for updating and integrating covariate information into key parameters of metabolizable energy (ME) systems for dairy cows. The study addressed specifically the effects of genetic improvements and feed quality on key parameters in current ME systems. These are net and metabolizable energy for maintenance (NEM and MEM, respectively), efficiency of utilization of ME for milk production (kL) and growth (kG), and efficiency of utilization of body stores for milk production (kT). Data were collated from 38 studies, yielding 701 individual cow observations on milk energy, ME intake, and tissue gain and loss. A function based on a linear relationship between milk energy and ME intake and correcting for tissue energy lo...
2011-01-01
International Nuclear Information System (INIS)
The Mizunami Underground Research Laboratory (MIU) of the Japan Atomic Energy Agency is a major site for geoscientific research to advance the scientific and technological basis for geological disposal of high-level radioactive waste in crystalline rock. Studies on relevant engineering technologies in the MIU consist of a) research on design and construction technology for very deep underground applications, and b) research on engineering technology as a basis of geological disposal. In the Second Phase of the MIU project (the construction phase), engineering studies have focused on research into design and construction technologies for deep underground. The main subjects in the study of very deep underground structures consist of the following: 'Demonstration of the design methodology', 'Demonstration of existing and supplementary excavation methods', 'Demonstration of countermeasures during excavation' and 'Demonstration of safe construction'. In the FY 2007 studies, identification ...
2008-07-01
Pentobarbital anesthesia alters neural responses in the precedence effect.
The precedence effect (PE) is thought to be beneficial for proper localization and perception of sounds. The majority of recent physiological studies focus on the neural discharges correlated with PE in the inferior colliculus (IC). Pentobarbital anesthesia is widely used in physiological studies. However, little is known of the effect of pentobarbital on the discharge of neurons in PE. Neuronal responses in the IC from 23 male SD rats were recorded by standard extracellular recording techniques following presentation of 4 ms white noise bursts, presented from either or both of two loud speakers, at different interstimulus delays (ISDs). The neural responses were recorded for off-line analysis before or after intraperitoneal administration of pentobarbital at a loading or maintenance dose. Data were assessed by one-way repeated measures analysis of variance and pairwise comparisons. When the ipsilateral stimuli were leading, pentobarbital at a loading dose ...
2011-05-06
PNC`s proposal on the Advanced Fuel Recycle concept
Energy Technology Data Exchange (ETDEWEB)
MOX fuel for FBR is allowed to contain impurities within several thousand ppm, which means less than 1000 of decontamination factor (DF) in reprocessing is enough for Pu and U recycle use. The Advanced Fuel Recycle proposed by PNC is on this basis. The concept consists of innovations on both MOX fuel fabrication and aqueous reprocessing technologies based on the Purex process and it is believed that successful optimization of fuel cycle interface condition is the key issue to realize the concept. The lower DF such as 1000 can be easily obtained by the simplified Purex flowsheet which has no purification steps. However, new subject arises in MOX fuel fabrication, that is, fabrication is conducted in the shielding cell using equipment which is maintained remotely. A simplified fabrication technology becomes essential to establish the remote maintenance system and is one of the critical path for achieving the Advanced Fuel Recycle. The PNC`s proposal on the advanced ...
1998-03-01
Energy Technology Data Exchange (ETDEWEB)
A study of advancements in power plant designs for use at geothermal resources in the low to moderate (300 to 400F) temperature range is reported. In 3 case studies, the benefits of R and D to achieve these advancements are evaluated in terms of expected increases in installed geothermal generating capacity over the next 2 decades. A parametric sensitivity study is discussed which analyzes differential power development for combinations of power plant efficiency and capitol cost. Affordable tradeoffs between plant performance and capital costs are illustrated. The independent review and analysis of the expected costs of construction, operation and maintenance of the Heber Binary Cycle Geothermal Power Demonstration Plant are described. Included in this assessment is an analysis of each of the major cost components of the project, including (1) construction cost, (2) well field development costs, (3) fluid purchase costs, and (4) well field and power plant operation ...
1983-06-30
Finalisation of design provision for active process water system shut down at TAPP-3 and 4
International Nuclear Information System (INIS)
Active Process Water (APW) system is provided as a unitized system in TAPP-3 and 4. Maintenance on APW system requires shutdown of this system. As shut down heat exchangers are fed by APW system; during APW system shutdown cold shutdown state cannot be maintained. Therefore safety analysis is done to optimize the duration of reactor shutdown (which means low decay heat) after which APW shutdown can be taken with minimum water supply to the shutdown heat exchangers. Based on this analysis, it is proposed in technical specification that APW system shutdown can be taken after 7 days of reactor shutdown with shutdown heat exchangers supplied with about 20 % of normal APW flow. With this configuration, PHTS, moderator, end shield, calandria vault water temperature can be maintained within limits. A design provision is made at TAPP-3 and 4 to interconnect APW system of both units in such a way that one unit in addition to its own APW requirement can provide limited ...
2006-11-13
FFTF operational results: startup to 100 MWd/kg
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF) is a 400-MW(t) sodium-cooled fast reactor operating at the Hanford Engineering Development Laboratory in Richland, Washington, to conduct fuels and materials testing in support of the US liquid-metal fast breeder reactor program. Startup and initial power testing included a comprehensive series of nuclear and nonnuclear tests to verify the thermal and neutronic characteristics of the plant and to demonstrate its inherent safety features. Extensive reactor core characterization measurements were completed to provide the neutron and gamma spectra, fission rates, and other physics data needed to design and evaluate tests irradiated in the FFTF. A specially designed series of natural-circulation tests was performed to demonstrate the inherent safety features of the plant. Early in 1982 the FFTF began its first 100-d irradiation cycle. Since that time the plant has operated beyond expectations; it achieved a cycle capacity factor of 99.5% in the most ...
International Nuclear Information System (INIS)
The Department of Energy (DOE), Western Area Power Administration (Western) proposes to consolidate segments of two transmission lines near the Gering Substation in Gering, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska, within the city of Gering. Presently, there are three parallel 115-kilovolt (kV) transmission lines on separate rights-of-way (ROW) that terminate at the Gering Substation. The project would include dismantling the Archer-Gering wood-pole transmission line and rebuilding the remaining two lines on single-pole steel double circuit structures. The project would consolidate the Gering-Stegall North and Gering-Stegall South 115-kV transmission lines on to one ROW for a 1.33-mile segment between the Gering Substation and a point west of the Gering Landfill. All existing wood-pole H-frame structures would be removed, and the Gering-Stegall North and South ROWs ...
1999-05-01
Energy Technology Data Exchange (ETDEWEB)
The Department of Energy (DOE), Western Area Power Administration (Western) proposes to consolidate segments of two transmission lines near the Gering Substation in Gering, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska, within the city of Gering. Presently, there are three parallel 115-kilovolt (kV) transmission lines on separate rights-of-way (ROW) that terminate at the Gering Substation. The project would include dismantling the Archer-Gering wood-pole transmission line and rebuilding the remaining two lines on single-pole steel double circuit structures. The project would consolidate the Gering-Stegall North and Gering-Stegall South 115-kV transmission lines on to one ROW for a 1.33-mile segment between the Gering Substation and a point west of the Gering Landfill. All existing wood-pole H-frame structures would be removed, and the Gering-Stegall North and South ROWs ...
1995-05-01
Energy Technology Data Exchange (ETDEWEB)
This report discusses a representation scheme of device failures anticipated in nuclear power plant, to describe related knowledge in a computer software. Coping ability covering a wide range of physical events is desired in plant operators and maintenance staffs, but it is impractical to give them a set of experience to cover the all possible events in the education/training curriculum. However, in case that their knowledge of plant design and of generally-known physical principles are enforced, their ability of cause identification and of appropriate responding actions against inexperienced events are expected to be enhanced, by combining the basic engineering and physical knowledge. Most of the anomalies anticipated in nuclear power plants are initiated as an incipient failure in some auxiliary equipment initially affecting only within the relative subsystem and hiding from the central control room, and then are propagated to deviate process parameters in the ...
1999-03-01
Coordinating decentralized optimization of truck and shovel mining operations
Energy Technology Data Exchange (ETDEWEB)
Canada's oil sands contain the largest known reserve of oil in the world. Oil sands mining uses 3 functional processes, ore hauling, overburden removal and mechanical maintenance. The industry relies mainly on truck-and-shovel technology in its open-pit mining operations which contributes greatly to the overall mining operation cost. Coordination between operating units is crucial for achieving an enterprise-wide optimal operation level. Some of the challenges facing the industry include multiple or conflicting objectives such as minimizing the use of raw materials and energy while maximizing production. The large sets of constraints that define the feasible domain pose as challenge, as does the uncertainty in system parameters. One solution lies in assigning truck resources to various activities. This fully decentralized approach would treat the optimization of ore production, waste removal and equipment maintenance independently. It ...
2006-07-01
Scientific Electronic Library Online (English)
Abstract in english Human organism is interpenetrated by the world of microorganisms, from the conception until the death. This interpenetration involves different levels of interactions between the partners including trophic exchanges, bi-directional cell signaling and gene activation, besides genetic and epigenetic phenomena, and tends towards mutual adaptation and coevolution. Since these processes are critical for the survival of individuals and species, they rely on the existence of a c (more) omplex organization of adaptive systems aiming at two apparently conflicting purposes: the maintenance of the internal coherence of each partner, and a mutually advantageous coexistence and progressive adaptation between them. Humans possess three adaptive systems: the nervous, the endocrine and the immune system, each internally organized into subsystems functionally connected by intraconnections, to maintain the internal coherence of the system. The three adaptive ...
2001-04-01
Assessing the internal mechanical integrity of power transformers using vibration tests
Energy Technology Data Exchange (ETDEWEB)
Machine condition monitoring (MCM) has the capability to predict equipment maintenance needs which can reduce forced down-time and facilitate the avoidance of catastrophic failures and the consequential secondary damage. It can be used to allow confident deferral of routine maintenance, and improve equipment performance, availability, reliability and safety. In order to capitalize on the potential benefits of MCM directed toward power transformers two types of vibration tests were conducted on transformers owned and operated by Cargill Inc. and IES Utilities at the Bridgeport corn plant in Eddyville, Iowa. These tests involved collecting vibration signals from the transformer tank walls during transformer energization at no-load and during steady state operation at various loads. These vibration signals were then used to detect deterioration of internal mechanical integrity. Both types of tests conducted on the transformers at the Eddyville ...
1996-12-31
Application of distributed and parallel technology in nuclear power plant engineering simulator
International Nuclear Information System (INIS)
A nuclear power plant engineering (NPP) simulator may include many system functions such as thermal-hydraulic calculation, 3D reactor neutron kinetics model, control and protection system, display and operational human-machine interface, intelligent alarm system, etc. If all those functions are simulated using a single code, the size of the program will cause structural or managerial problems, and the hardware requirement could be tremendous. Thus, any local function errors or changes may affect the whole code, which will make development and maintenance extremely costly. So the nondistributed code is not considered to be flexible and feasible. Currently, distributed and parallel technologies have been applied to develop NPPs engineering simulator for safety analysis, verification of advanced main control room display, operation and intelligent alarm design. The distributed simulation divides a huge task into several objects according to different functions. ...
Advances in human reliability analysis in Mexico
Energy Technology Data Exchange (ETDEWEB)
Human Reliability Analysis (HRA) is a very important part of Probabilistic Risk Analysis (PRA), and constant work is dedicated to improving methods, guidance and data in order to approach realism in the results as well as looking for ways to use these to reduce accident frequency at plants. Further, in order to advance in these areas, several HRA studies are being performed globally. Mexico has participated in the International HRA Empirical study with the objective of -benchmarking- HRA methods by comparing HRA predictions to actual crew performance in a simulator, as well as in the empirical study on a US nuclear power plant currently in progress. The focus of the first study was the development of an understanding of how methods are applied by various analysts, and characterize the methods for their capability to guide the analysts to identify potential human failures, and associated causes and performance shaping factors. The HRA benchmarking study has been performed by using the ...
2010-10-15
International Nuclear Information System (INIS)
Renal osteodystrophy is a metabolic bone disease and a common complication of end-stage chronic renal failure and maintenance dialysis treatment. In this study, we examined the correlation between quantifying bone scintigraphy and serum biochemical markers in hemodialysis patients. Bone scintigraphy with technetium-99m-hydroxy-methylene-diphosphonate ("9"9"mTc-HMDP) was performed on 28 patients on maintenance hemodialysis. Bone scintigraphy was performed using a standard protocol and was quantified by setting regions of interest (ROIs) over selected regions. The bone-to-soft-tissue ratio (B/ST ratio) at each region was calculated in all patients. The B/ST ratios were then compared with serum biochemical markers. The B/ST ratio for the skull correlated well with serum bone-specific alkaline phosphatase (BAP) (r=0.735, p<0.001), serum deoxypyridinoline (DPD) (r=0.806, p<0.001) and intact parathyroid hormone (intact PTH) (r=0.701, ...
2004-09-01
A study on the management of spent fuel storage capacity in South Korea
International Nuclear Information System (INIS)
The saturation of South Korea's at-reactor (AR) spent fuel storage pools will create a necessity for additional spent fuel storage capacity. Because the South Korean government has the plan to increase the number of nuclear power plants from 20 units (end of 2005) to 27 units by 2015, the increase of spent nuclear fuel generation will be accelerated. Because there is no clear national plan for spent nuclear fuel storage and disposal, the utility company (Korea Hydraulic Nuclear Power company) is planning to construct a spent fuel storage facility with 11 000 tHM capacity for Pressurised Water Reactor (PWR). This study is intended to predict the maximum allowable periods when the storage facility will be fully occupied with respect to the already fixed re-racking plan of spent fuel storage pools and construction of new nuclear power plants. The result from this study will be used as fundamental data for an efficient management of the spent fuel storage capacity up to the time of the ...
2006-06-19
Challenges for Lithuania: Ignalina NPP Early Closure
International Nuclear Information System (INIS)
As a condition of accession into the European Union (EU), Lithuania is committed to the closure and decommissioning of Ignalina NPP comprising two RBMK-1500 reactor units (Fig. 1). It was agreed in a special protocol to the Accession Treaty that, in return for adequate EU financial assistance, Unit 1 would be closed before 2005 and Unit 2 by the end of 2009. The first unit was duly shut down on December 31, 2004. Lithuania, which has borders with Russia (Kaliningrad territory), Poland, Latvia and Belarus, spent fifty years as part of the Soviet Union and was deeply integrated into its economy and electrical infrastructure. At the break-up of the USSR, Lithuania inherited electricity generating capacity designed to supply the north-west region including ownership of Ignalina NPP located in the north-east of the country. Ignalina NPP Unit 1 was commissioned in 1983, Unit 2 in 1987; the planned lifespan of each unit was 30 years. Construction of a third unit was started but never ...
2008-01-01
White Rose Development Plan amendment South White Rose extension tie back
Energy Technology Data Exchange (ETDEWEB)
In January 2001, Husky Oil Operations Limited (Husky), in joint-venture with Petro-Canada submitted a Development Application (DA) to the Canada-Newfoundland and Labrador Offshore Petroleum Board (C-NLOPB) for the White Rose Development. This DA was prepared following the Canada-Newfoundland Atlantic Accord Implementation Act and the Canada-Newfoundland and Labrador Atlantic Accord Implementation Newfoundland and Labrador Act. In December 2001, the C-NLOPB approved the White Rose DA. This document outlined a proposed amendment to the original Development Plan involving an expansion of its White Rose Development in the Jeanne d'Arc Basin on the Grand Bank. The expansion will consist of a subsea tie-back to the Floating Production, Storage and Offloading (FPSO) vessel through the existing Southern Glory Hole (SGH) and utilizing a new glory hole constructed approximately 4 km south of the SGH. The document presented an overview of the development; geology, geophysics and ...
2006-09-15
Waste sampling and characterization facility (WSCF)
Energy Technology Data Exchange (ETDEWEB)
The Waste Sampling and Characterization Facility (WSCF) complex consists of the main structure (WSCF) and four support structures located in the 600 Area of the Hanford site east of the 200 West area and south of the Hanford Meterology Station. WSCF is to be used for low level sample analysis, less than 2 mRem. The Laboratory features state-of-the-art analytical and low level radiological counting equipment for gaseous, soil, and liquid sample analysis. In particular, this facility is to be used to perform Resource Conservation and Recovery Act (RCRA) of 1976 and Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) of 1980 sample analysis in accordance with U.S. Environmental Protection Agency Protocols, room air and stack monitoring sample analysis, waste water treatment process support, and contractor laboratory quality assurance checks. The samples to be analyzed contain very low concentrations of radioisotopes. The main reason that WSCF is considered a ...
1994-10-01
Visualization of growth factor receptor sites in rat forebrain
International Nuclear Information System (INIS)
It is now known that various growth factors may also act in the central nervous system. Among them, it has recently been shown that epidermal growth factor (EGF) and insulin-like growth factor I (IGF-I) may possess trophic effects in the mammalian brain. We report here on the respective autoradiographic distribution of ["1"2"5I]EGF and ["1"2"5I]IGF-I receptor binding sites in the rat brain, both during ontogeny and in adulthood. It appears that ["1"2"5I]EGF sites are mostly found in the rat forebrain during brain development. On the other hand, ["1"2"5I]IGF-I sites are more widely distributed both during ontogeny and in adulthood. These results reveal the plasticity of the expression of EGF and IGF-I receptor sites in the mammalian brain. This could be relevant for the respective role of these two growth factors in the development and maintenance of neuronal function.
Validation and verification of the ORNL Monte Carlo codes for nuclear safety analysis
International Nuclear Information System (INIS)
The process of ensuring the quality of computer codes can be very time consuming and expensive. The Oak Ridge National Laboratory (ORNL) Monte Carlo codes all predate the existence of quality assurance (QA) standards and configuration control. The number of person-years and the amount of money spent on code development make it impossible to adhere strictly to all the current requirements. At ORNL, the Nuclear Engineering Applications Section of the Computing Applications Division is responsible for the development, maintenance, and application of the Monte Carlo codes MORSE and KENO. The KENO code is used for doing criticality analyses; the MORSE code, which has two official versions, CGA and SGC, is used for radiation transport analyses. Because KENO and MORSE were very thoroughly checked out over the many years of extensive use both in the United States and in the international community, the existing codes were open-quotes baselined.close quotes This means that ...
1993-11-14
Utility activities that create power quality problems
Energy Technology Data Exchange (ETDEWEB)
Power quality problems are caused by activities normal to utility operations such as maintenance outages and capacitor switching or events that are abnormal such as lightning strikes and equipment failures. Disconnection and reconnection of transmission lines and transformers can cause switching surges, and are more severe on extra high voltage transmission lines than high voltage lines. Capacitor switching can cause transients and harmonics that may affect sensitive equipment, and are the source of 3rd, 5th, 7th and 9th harmonics in the hundreds of hertz ranges. Overload, sudden loss of generating capacity and transmission line faults are typical problems affecting system stability. Fault interruptions and reclosings can cause surges in the distribution system, and lightning strikes may cause voltage surges or dips due to arrester sparkover. Blackouts, brownouts, voltage fluctuations, travelling wave overvoltages, capacitor restrikes, harmonics and harmonic ...
1992-02-01
Energy Technology Data Exchange (ETDEWEB)
The performance of a group of reference laboratories measuring lead in blood, has been monitored by an intensive external quality assessment programme, since 1974. Performance was similar to that observed in other, larger quality control surveys but rapidly improved following detailed investigations of critical factors in the analytical methodology. The introduction of a rigorous internal quality control protocol, with all laboratories using the same well-characterised materials, has produced external quality control results that are both accurate and very tightly distributed. Between-laboratory coefficients of variation of less than 5%, less than 6% and less than 20% are now obtained at concentrations of over 1.0 ..mu..mol/l (20.7 ..mu..g/dl), 0.5-1.0 ..mu..mol/l (10-20 ..mu..g/dl) and less than 0.5 ..mu..mol/l (10 ..mu..g/dl), respectively. These results represent the best that can be achieved by current methodology and instrumentation in regular, daily use.
1988-12-01
International Nuclear Information System (INIS)
The US Department of Energy has provided support to four universities and the Oak Ridge National Laboratory in order to pursue research leading to the development and deployment of an advanced robotic system capable of performing tasks that are hazardous to humans, that generate significant occupational radiation exposure, and/or whose execution times can be reduced if performed by an automated system. The goal is to develop a generation of advanced robotic systems capable of performing surveillance, maintenance, and repair tasks in nuclear facilities and other hazardous environments. This goal will be achieved through a team effort among the Universities of Florida, Michigan, Tennessee, Texas, and the Oak Ridge National Laboratory, and their industrial partners, Combustion Engineering, Martin Marietta Baltimore Aerospace, Odetics, Remotec, and Telerobotics International. Each of the universities and ORNL have ongoing activities and corresponding facilities in ...
Cytosine methylation in DNA is a major epigenetic signal, and plays a central role in propagating chromatin status during cell division. However the mechanistic links between DNA methylation and histone methylation are poorly understood. A multi-domain protein UHRF1 (ubiquitin-like, containing PHD and RING finger domains 1) is required for DNA CpG maintenance methylation at replication forks, and mouse UHRF1-null cells show enhanced susceptibility to DNA replication arrest and DNA damaging agents. Recent data demonstrated that the SET and RING associated (SRA) domain of UHRF1 binds hemimethylated CpG and flips 5-methylcytosine out of the DNA helix, whereas its tandom tudor domain and PHD domain bind the tail of histone H3 in a highly methylation sensitive manner. We hypothesize that UHRF1 brings the two components (histones and DNA) carrying appropriate markers (on the tails of H3 and hemimethylated CpG sites) ready to be assembled into a nucleosome after ...
2009-01-01
Toward success of a market mobilization effort: the National Earth Comfort Program
Energy Technology Data Exchange (ETDEWEB)
Work of the Geothermal Heat Pump Consortium (GHPC), a joint program of the US Department of Energy, the US Environmental Protection Agency, the US electric utilities and industry was described. The consortium was established to improve energy efficiency and reduce CO{sub 2} emissions by moving ground source and groundwater source heat pumps from niche products to ten percent of the new and retrofit HVAC market in less than a decade. The GHPC program focuses on : (1) reducing first costs through technology innovation and innovative financing, (2) strengthening the infrastructure though education, training and work codes and regulations, and (3) building confidence in the technology through demonstrations of cost-effectiveness, low maintenance efforts and through marketing programs. Results of the first two years of operations were described. Results indicate that the objectives are being achieved, the number of installations is increasing and a solid foundation is ...
1997-11-01
Tissue equivalent proportional counter real time neutron monitor
International Nuclear Information System (INIS)
The Tissue Equivalent Proportional Counter (TEPC) was developed to monitor low level neutron exposure rates at working stations in a nuclear fuel fabrication facility. It has proven capable of accurately measuring neutron dose rates at levels from 0.1 to 0.2 mrem/hr. It also calculates the Quality Factor which is of importance in locations where the neutron to gamma ratio may vary significantly and irregularily. The system described is computerized to monitor 100 work locations simulationeously and can be expanded to monitor 384 locations. Neutron dose is accumulated on a real time basis and after the proton drop point is established, dose rate can be read out at any time for the dose accumulated over a specified period of time. The current development program which provides reduced system maintenance, lower detection limits, and improved accuracy is discussed along with examples of measurement data and work experience with the current system.
1978-10-25
The new IC3 intercity train. Modern diesel trainsets for the Danish State Railways
Energy Technology Data Exchange (ETDEWEB)
An ambitious development programme culminated in late 1989 with the most modern diesel train available today entering commercial service. At the root of its development lay an overall concept which aimed at meeting the present-day and future requirements of railway administrations. Higher passenger revenues, lower operating costs and reduced maintenance are the result. An IC trainset is 58.8 m long and consists of three cars: Two identical power cars and one intermediate car. Each three-car trainset has 144 seats, 16 of which are reserved for first class. Up to five three-car trainsets can be coupled rogether to form a 15-car trainset. Four air-cooled 8-cylinder diesel engines with a combined rating of 294 kW power each three-car trainset, i.e. there are two engines installed in each of the power cars. The train has a maximum speed of 180 km/h. (orig.).
1990-01-01
Energy Technology Data Exchange (ETDEWEB)
A lower energy efficiency standard for buildings (EPC) can have a negative impact on thermal comfort and indoor air quality. Cooperation and integrated design are preconditions for a correct use, installation and maintenance of heating and ventilation systems in buildings. [Dutch] Er komt steeds meer kritiek op de wijze waarop in ons land woningen en gebouwen worden gebouwd. Op dit moment is het vooral woonhuisventilatie waar veel om te doen is. Van beleidsmakers tot aannemers en van Consumentenbond tot gezondheidsdiensten; iedereen vraagt zich af of we met vergaande isolatie onze woningen en gebouwen nog wel leefbaar houden. In dit artikel wordt een pleidooi gehouden voor onderlinge samenwerking en integraal ontwerp als randvoorwaarden voor een goede toepassing, installatie en onderhoud van verwarmings- en ventilatiesystemen in gebouwen.
2006-09-15
Energy Technology Data Exchange (ETDEWEB)
Using an economic perspective, it is possible to make a case for green buildings and green development practices by placing emphasis on Energy Efficiency and Environmental Design. Several case studies have demonstrated that green buildings save money through reduced consumption of natural resources, electricity and gas both at the building site and at the source of energy. Sound environmental practices and energy efficiency measures improve the environmental conditions throughout the state by reducing power plant emissions and reducing operations and maintenance budgets in the state. The author presented a case study where a green development project was guided and monitored using the Environmental Performance Rating System called Leadership in Energy and Environmental Design (LEED), version 2.0. The work was registered to achieve LEED certification. A brief study on current construction related costs was also included. 2 refs., 1 fig.
2003-07-01
Energy Technology Data Exchange (ETDEWEB)
There is an urgent need to monitor the condition of fluid-filled taped (FFT) cables. The Dissolved-Gas Analysis (DGA) technique that has been successfully applied to power transformers holds great potential for the preventive maintenance of FFT cables. However, before this emerging technique can be properly applied to cables, a suitable fluid sampling and subsequent gas analysis method had to be developed, including the generation of both laboratory and field data to aid in data interpretation. Data on gas saturation levels in various cable fluids have been presented. This paper describes a novel method developed specifically for FFT cables and discusses field results so obtained. The type, distribution and concentration of gases from fluid alone and paper alone under electrical stress has been presented, including the differences between normal and not-so-normal cable systems as demonstrated by DGA. The concept of wet tensile strength has been introduced to the ...
1994-12-31
The French design code: RCC-M status and on-going developments
International Nuclear Information System (INIS)
Since 1978, an important effort has been on-going between Framatome and Electricite de France (EDF) to develop and update technical rules for the design and construction of nuclear power plants. Two design codes are developed, one for PWRs: RCC-M and one for FBRs: RCC-MR. After some comments on the organization of RCCM Commission, the paper presents: (1) the major differences with the ASME Section III Code for fatigue, plastic shakedown and rupture analysis; (2) the review of some important facts in terms of availability or maintenance costs (in-service inspection, replacements, repairs, etc.) of operating plants like underclad cracking, stratification, CRDM nozzles, cast elbows, steam generator tubes, etc.; (3) how can one take into consideration this operating feedback in RCC-M Code; and (4) few examples of major on-going developments for fracture analysis on different components and fatigue analysis of valves. In conclusion, the standardization of the plants is ...
1996-07-21
Test-bed for compact ventilation units; Pruefstand fuer Kompaktlueftungsgeraete fuer Komfortlueftung
Energy Technology Data Exchange (ETDEWEB)
This comprehensive, illustrated report for the Swiss Federal Office of Energy (SFOE) by the University of Applied Sciences in Lucerne, Switzerland takes a look at the testing facility at the university that is used to test compact ventilation systems. These feature heat-recovery and return-air heat-pumps and are used in housing built to low energy-consumption standards such as the Swiss 'Minergie' and 'Minergie-P' standards. The primary goal is a technically comprehensive testing programme for compact ventilation units with heat recovery and heat pumps, which can nevertheless be carried out at reasonable cost. In addition to thermal and flow measurements, acoustic measurements are also carried out. The authors quote that the overall assessment provided can also include service and maintenance, materials used and possible problems with thermal bridges. The test installation is described and the testing regulations used are ...
2005-12-15
Energy Technology Data Exchange (ETDEWEB)
Data which have been collected by Los Alamos National Laboratory waste management for the hydrologic characterization of the subsurface at the low level radioactive waste disposal facility, Area G, are reported and discussed briefly. The data includes Unsaturated Flow Apparatus measurements of the unsaturated conductivity in samples from borehole G-5. Analysis compares these values to the predictions from van Genuchten estimates, and the implications for transport and data matching are discussed, especially at the location of the Vapor Phase Notch (VPN). There, evaporation drives a significant vapor flux and the liquid flux cannot be measured accurately by the UFA device. Data also include hydrologic characterization of samples from borehole G-5, Area G surface soils, Los Alamos (Cerros de Rio) basalt, Tsankawi and Cerro-Toledo layers, the Vapor Phase Notch (VPN), and additional new samples from the uppermost tuff layer at Area G. Hydraulic properties from these sample groups can be ...
1998-03-01
Energy Technology Data Exchange (ETDEWEB)
This final report for the Swiss Federal Office of Energy (SFOE) is one of a series of reports concerning municipal development in various cities in Switzerland. The four city districts involved include Basel (Gundeldinger Feld), Lausanne (Bellevaux), Lucerne (Basel-/Bernstrasse) and Zurich (Werdwies). This paper takes a look at aspects of building ecology. In the four areas, the following building types and projects were examined with respect to their ecology: Basel: conversion of commercial premises to a community centre, Lausanne and Lucerne: Enhancement of residential areas, Zurich: a new residential building. Criteria examined include general building ecology, building materials, raw materials, toxic substances, recycling, maintenance and deconstruction, energy for heating and hot water, grey energy, electricity, ground usage, water, wastes and public infrastructure. Knowledge gained along with questions and problems still to be addressed are summarised and ...
2004-07-01
International Nuclear Information System (INIS)
Tarapur Atomic Power Station Unit-3 and 4 (TAPS -3 and 4) are the 540 MWe reactors. Unit-4 attained first criticality on 06th March 2005 and operated for about 230 effective full power days (EFPD). Unit-3 attained first criticality on 21st May 2006 and operated for about 20 EFPD. With the reactor operation radiation field increases on the Primary Heat Transport system equipments, Moderator system equipments and auxiliary system equipments due to deposition of fission products and activation products in different reactor systems. These dose rates significantly contributes to the external exposure and stations collective dose during reactor operation, refueling operation and maintenance activities. A study was undertaken at TAPS 3 and 4 to identify the system equipments showing the significant dose rates and identify the radionuclides present in the primary heat transport system, Moderator systems, cover gas system and other auxiliary system for incorporating the ...
2006-11-13
Energy Technology Data Exchange (ETDEWEB)
Recently, the lithium ion-conductive solid electrolyte draws attention because there is a possibility of producing the maintenance-free battery which is characterized by having such advantages as high energy density and no possibility of electrolyte leak because of solid state structure. The invented lithium ion-conductive solid electrolyte is formed by sintering the granular electrolyte expressed in the following general formula: Li(1+(4-n)x)MxTi(2-x)(PO4)3 (M = mono- or di-valent cation, x = 0.1 - 0.5). Examples of the monovalent cation are Na[sup +], K[sup +], Rb[sup +], Cs[sup +], and Cu[sup +]. Examples of divalent cation are Mg[sup 2+], Fe[sup 2+], Be[sup 2+], Ca[sup 2+], Sr[sup 2+], Ba[sup 2+], Ra[sup 2+], Mn[sup 2+], Co[sup 2+], Cu[sup 2+], Ni[sup 2+], Zn[sup 2+], and Cd[sup 2+]. The electric conductivity of lithium ion is increased with the increase in the content of Li[sup +] in the electrolyte. 4 figs.
1993-11-12
Slope stability and stabilization methods
Energy Technology Data Exchange (ETDEWEB)
Slope stability can be a major problem during the construction of surface facilities. Cutting into existing ground disturbs the mechanics of the surrounding area, which can result in landslides and rock falls. This practical reference gives you the comprehensive information you need for slope stability analysis, suitable methods of analysis with and without the use of computers, and examples of common stability problems and stabilization methods for cuts and fills. It includes detailed discussions of methods used in slope stability analysis, including the Ordinary Method of Slices, Simplified Janbu Method, Simplified Bishop Method, Spencer`s Method, other limit equilibrium methods, numerical methods, total stress analysis, effective stress analysis, and the use of computer programs to solve problems. Chapters include: General Slope Stability Concepts; Engineering Geology Principles; Groundwater Conditions; Geologic Site Exploration; Laboratory Testing Interpretation; Slope Stability ...
1995-12-01
Site Operator technical report. Final report (1992--1996)
Energy Technology Data Exchange (ETDEWEB)
The Southern California Edison Company (SCE) and the US Department of Energy (DOE) entered into cooperative agreement No. DE-FC07-91ID13077 on August 23, 1991, which expired on August 3, 1996. This cooperative agreement provided SCE with DOE cofunding for participation in the DOE`s Electric and Hybrid Vehicle Site Operator Program. In return, SCE provided the DOE with quarterly progress reports which include operating and maintenance data for the electric (EVs) vehicles in SCE`s fleet. Herein is SCE`s final report for the 1992 to 1996 agreement period. As of September 1, 1996 the SCE fleet had 65 electric vehicles in service. A total of 578,200 miles had been logged. During the agreement period, SCE sent the DOE a total of 19 technical reports (Appendix B). This report summarizes the technical achievements which took place during a long, productive and rewarding, relationship with the DOE.
1996-12-01
Energy Technology Data Exchange (ETDEWEB)
Using a coplanar, end-mounted antenna as a baseline, various configuration trades were performed to select a preferred solid state concept. The increase in efficiency that could be realized by use of multi bandgap solar cells, either with klystron or solid state antenna was evaluated. Satellite configurations were developed to exploit the sandwich antenna concept wherein solar cells are located on one side of the antenna panel and solid state dc/RF converters on the other side. These concepts entailed various primary and secondary reflector arrangements for directing solar energy to the solar cell side of the antenna with higher concentration ratios than used on the coplanar configurations. Operations analysis included development of a satellite construction scenario, a concept for the SCB, a top-level satellite construction operation, construction operation, construction timelines and crew sizes, mass flows to orbit, and a satellite maintenance scenario. The list ...
1981-03-01
Review of compliance with EU-2010 targets on renewable energy in Galicia (Spain)
Energy Technology Data Exchange (ETDEWEB)
The use of renewable energy offers a range of exceptional benefits, including: a decrease in external energy dependence; a boost to local and regional component manufacturing industries; promotion of regional engineering and consultancy services specialising in the use of renewable energy; increased R and D, decrease in impact of electricity production and transformation; increase in the level of services for the rural population; creation of employment, etc. To achieve these benefits, a series of actions are required, among which the following are particularly important: creation of a suitable climate for performing R and D; training of technicians in design, production and maintenance of equipment; motivation for establishing a new market; proper financing; fostering of appropriate technologies; practical demonstration of results, etc. This article reviews the progress made in the Autonomous Community of Galicia in terms of the introduction of renewable energy ...
2006-06-15
Remote disassembly of the absorber open-test assembly at the FFTF/IEM cell
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF) interim examination and maintenance (IEM) cell is used for the remote disassembly of irradiated fuel and material experiments. The absorber open-test assembly (AOTA) is a 12-m (40-ft)-long instrumented absorber (control-rod-material) test assembly. Its primary purpose is to characterize the FFTF control-rod-material reaction rate during reactor operation. Instrumentation allowed temperature and pressure measurements at various locations in several absorber pins during reactor operation. After residing several months in the reactor, the assembly was transferred to the IEM cell by the closed-loop ex-vessel machine (CLEM) for separation of the irradiated portion of the experiment from the instrument stalk. After separation, the 3.6-m (12-ft)-long assembly was processed through the sodium removal system and shipped off-site for examination. This success allowed the timely completion of a major task on the FFTF operations schedule.
1990-11-11
Remedial Design/Remedial Action Work Plan for Operable Units 6-05 and 10-04, Phase IV
Energy Technology Data Exchange (ETDEWEB)
This Phase IV Remedial Design/Remedial Action Work Plan addresses the remediation of areas with the potential for UXO at the Idaho National Laboratory. These areas include portions of the Naval Proving Ground, the Arco High-Altitude Bombing Range, and the Twin Buttes Bombing Range. Five areas within the Naval Proving Ground that are known to contain UXO include the Naval Ordnance Disposal Area, the Mass Detonation Area, the Experimental Field Station, The Rail Car Explosion Area, and the Land Mine Fuze Burn Area. The Phase IV remedial action will be concentrated in these five areas. For other areas, such as the Arco High-Altitude Bombing Range and the Twin Buttes Bombing Range, ordnance has largely consisted of sand-filled practice bombs that do not pose an explosion risk. Ordnance encountered in these areas will be addressed under the Phase I Operations and Maintenance Plan that allows for the recovery and disposal of ordnance that poses an imminent risk to human ...
2006-11-14
Energy Technology Data Exchange (ETDEWEB)
The hydro-generators suffer during its operative useful life a combination of stresses of nature thermal, electric, mechanics and environmental. With the time, they are going losing the capacity to support those stresses and the power plants suffer, more and more frequently, undesirable stops for repair services and maintenance. In function of the high costs incurred with these stopped, the operation of the power plant can be economically impracticable. That unavailability of the generation for the electric system, it results in reduction of the reliability, burdening the politics of load ruling. The re-potentiation is a proposal that seeks to extend the useful life of hydro-generators, at the same time that it try to rescue the reliability and the readiness of the plant, with larger power. The power increase is usually made possible, or for the surplus of the hydro resources in excess, or for the reduction of the losses of all the components of the energy flow. ...
1996-07-01
Quality assurance requirements for packaging and transportation of radioactive materials
International Nuclear Information System (INIS)
This paper discusses the new quality assurance regulations of the Nuclear Regulatory Commission (NRC) for packaging and transportation of radioactive materials. These regulations became effective on October 18, 1977. Background information concerning these regulations and packaging and transportation history is included. The quality assurance program is described with indications of how it is composed of general (administrative) provisions which must meet the 18 quality assurance criteria and be approved by the NRC; specific provisions which appear in the DOT and NRC regulations and in the individual package design approval; and other specific procedures which are not required by regulations but which are necessary for the proper control of quality. The quality assurance program is to be developed using a graded approach for the application of pertinent criteria and optimizing the required degree of safety and control efforts involved in achieving this level of safety. The ...
Proton exchange membrane fuel cells for distributed power generation
Energy Technology Data Exchange (ETDEWEB)
H Power Enterprises of Canada was founded in 1997; currently, it has 40 employees and expect to grow to about 50 by mid-2000. The company is engaged in fuel cell technology development , manufacturing and marketing. The company has the advantage that its technology has been proven, products are already commercialized, and strategic alliances are already in place to make an assault on the market. The concept of proton exchange membrane fuel cell technology is explained in terms of efficiency, response time, power density, stack manufacturing cost, maintenance cost, stack life and compatible thermal loads. Individual products, their energy and operating efficiency, potential applications and potential markets are reviewed. It is estimated that for stationary fuel cells the market will be worth $ 30 billion by 2030. In the United States alone, remote residential cogeneration sites are estimated at 500,000. The estimates for uses in transportation is estimated at $ 1 ...
2000-07-01
Energy Technology Data Exchange (ETDEWEB)
The purpose and need for DOE to undertake the actions described in this document are to improve the efficiency of the Alternating Gradient Synchrotron (AGS) complex. Benefits would include optimization of the AGS scientific program, increased high-energy and nuclear physics experimentation, improved health and safety conditions for workers and users, reduced impact on the environment and the general public, energy conservation, decreased generation of hazardous and radioactive wastes, and completion of actions required to permit the AGS to be the injector to the Relativistic Heavy Ion Collider (RHIC)., Improved efficiency is defined as increasing the AGS`s capabilities to capture and accelerate the proton intensity transferred to the AGS from the AGS booster. Improved capture of beam intensity would reduce the beam losses which equate to lost scientific opportunity for study and increased potential for radiation doses to workers and the general public. The action would also refurbish ...
1994-03-01
Proceedings of the 1996 oil heat technology conference and workshop
Energy Technology Data Exchange (ETDEWEB)
This Conference is a key technology transfer activity supported by the ongoing Combustion Equipment Technology (Oil-Heat R and D) program at BNL, and is aimed at providing a forum for the exchange of information among international researchers, engineers, manufacturers, and marketers of oil-fired space-conditioning equipment. The objectives of the Conference were to: identify and evaluate the state-of-the-art and recommend new initiatives for higher efficiency, a cleaner environment, and to satisfy consumer needs cost-effectively, reliably, and safely; and foster cooperation among federal and industrial representatives with the common goal of sustained national economic growth and energy security via energy conservation. The 1996 Oil Technology Conference comprised: (a) fourteen technical papers, and (b) four workshops which focused on mainstream issues in oil-heating technology, namely: oilheat research agenda forum; fan atomized burner commercialization, applications, and product ...
1996-07-01
Energy Technology Data Exchange (ETDEWEB)
This paper presents the experience faced by people who works in PETROBRAS Business Unit (UN-RNCE), located in Rio Grande do Norte Province, Brazil, during the implementation of a pipeline leak detection system. That application involved nine multiphase oil pipelines distributed along several production facilities. Because of the emergency after the leakage that polluted the Guanabara bay and due to the two phases and multi phases pipelines characteristics, the UN-RNCE decided to apply the Pressure Point Analysis (PPA) technology in order to detect leakages. It is a statistical method for leak detection e uses a very simple instrumentation which facilitates the installation and maintenance. However, in order to get the best performance of the system, it is necessary to know thoroughly the whole process and have a fast and reliable SCADA system for long distance communication. Finally it will be shown the test results, the recommendations to expand the system and the ...
2003-07-01
Energy Technology Data Exchange (ETDEWEB)
Controls of welds by radiographies are an efficient non destructive technique but it can be dangerous if not managed following a strict set of rules. EDF acts to avoid risks via several ways (adapted tools, best practices) and seeks for an integration of the radiographies with respect to the other maintenance operations, in order to raise the ratio of availability of the electricity production unit. This study explores an original analysis of industrial radiography: the influence of the representations of the workplace and its utilizations. This document supports the utilization of some space constraints as explanations of difficulties in the industrial radiography activity. The document proposes innovative points of view coming for on-site observations and from a theoretical background 'cognitive sciences' completed by technical propositions. (author)
2008-07-15
Precooling techniques and applications for horticultural products - a review
Energy Technology Data Exchange (ETDEWEB)
One of the most important factors affecting the postharvest life and quality of horticultural crops is temperature. Quality loss after harvest occurs as a result of physiological and biological processes, the rates of which are influenced primarily by product temperature. As the maintenance of market quality is of vital importance to the success of the horticultural industry, it is necessary not only to cool the product but to cool it as quickly as possible after harvest. The process of precooling is the removal of field heat which arrest the deteriorative and senescence processes so as to maintain a high level of quality that ensures customer satisfaction. This paper provides a critical review to portray precooling as an intricate part of temperature management and to highlight the importance of its utilisation for extending the shelf life and maintaining the quality of horticultural products with emphasis on cut flowers. Various different precooling methods are ...
2001-07-01
Energy Technology Data Exchange (ETDEWEB)
The analysis described demonstrates the use of benefit/cost sensitivity analysis in examining the wide range of potential damages and savings associated with converting oil-fired electric utility boilers to burn coal in Florida. This model, for the first time incorporates, in quantitative terms, environmental economic externalities into a benefit/cost ratio sensitivity analysis framework. Five different dose-response estimates of morbidity and mortality costs, property devaluation, and willing-to-pay estimates are used in combination with four acid rain dose-response models to estimate the net present worth of externality costs. The model estimates the net present worth of benefits by incorporating into a dynamic framework all relevant construction, O + M, and fuel costs of converting an electrical generation facility from using oil to coal. These benefits of fuel savings are then weighted against various combinations of externality costs associated with increased sulfur oxide emission ...
1984-01-01
Photovoltaic industry manufacturing technology. Final report
Energy Technology Data Exchange (ETDEWEB)
This report contains the results of the Photovoltaic (PV) Industry Manufacturing Technology Assessment performed by the Automation and Robotics Research Institute (ARRI) of the University of Texas at Arlington for the National Renewable Energy laboratory. ARRI surveyed eleven companies to determine their state-of-manufacturing in the areas of engineering design, operations management, manufacturing technology, equipment maintenance, quality management, and plant conditions. Interviews with company personnel and plant tours at each of the facilities were conducted and the information compiled. The report is divided into two main segments. The first part of the report presents how the industry as a whole conforms to ``World Class`` manufacturing practices. Conclusions are drawn from the results of a survey as to the areas that the PV industry can improve on to become more competitive in the industry and World Class. Appendix A contains the questions asked in the ...
1998-08-01
Performance of hybrid ball bearings in oil and jet fuel
Energy Technology Data Exchange (ETDEWEB)
A 308-size hybrid ball bearing, with ceramic balls and steel rings, was tested using a diester oil and gas turbine fuel as lubricants at several speeds and loads. Heat generation data from this test work was then correlated with the heat generation model from a widely used computer code. The ability of this hybrid split inner ring bearing design to endure thrust reversals, which are expected in many turbine applications, was demonstrated. Finally, the bearing was successfully endurance tested in JP-10 fuel for 25 hours at 7560 N axial load and 36,000 rpm. This work has successfully demonstrated the technology necessary to use fuel-lubricated hybrid bearings in limited-life gas turbine engine applications such as missiles, drones, and other unmanned air vehicles (UAVs). In addition, it has provided guidance for use in designing such bearing systems. As a result, the benefits of removing the conventional oil lubricant system, i.e., design simplification and reduced ...
1992-07-01
Energy Technology Data Exchange (ETDEWEB)
Daylight responsive dimming systems have been used in few buildings to date because they require improvements to improve reliability. The key underlying factor contributing to poor performance is the variability of the ratio of the photosensor signal to daylight workplane illuminance in accordance with sun position, sky condition, and fenestration condition. Therefore, this paper describes the integrated systems between automated roller shade systems and daylight responsive dimming systems with an improved closed-loop proportional control algorithm, and the relative performance of the integrated systems and single systems. The concept of the improved closed-loop proportional control algorithm for the integrated systems is to predict the varying correlation of photosensor signal to daylight workplane illuminance according to roller shade height and sky conditions for improvement of the system accuracy. In this study, the performance of the integrated systems with two improved ...
2010-07-08
Overview of the 1995 NATO ARW on nuclear submarine decommissioning and related problems
International Nuclear Information System (INIS)
The NATO Advanced Research Workshop on Nuclear Submarine Decommissioning and Related Problems was held in Moscow June 19--22, 1995. It was preceded by a visit to the Zvezdotchka Shipyard at Severodvinsk, a repair and maintenance yard for Russian nuclear submarines, for a subgroup of the workshop attendees. Most of the material in this paper is drawn directly form the workshop proceedings. Slightly less than 500 nuclear ships and submarines (the vast majority are submarines) have been constructed by the countries with nuclear navies. This includes approximately 250 by Russia, 195 by the United States, 23 by the United Kingdom, 11 by France and 6 by China. By the year 2000 it is expected that approximately one-half of these nuclear vessels will be removed from service and in various states of decommissioning. A newspaper account in June 1997 indicated that 156 Russian nuclear submarines had been removed from service. In August 1996 it was reported that 55 reactor ...
1997-11-21
Oscillating line travel pipe cleaning machine
Energy Technology Data Exchange (ETDEWEB)
A major problem in the maintenance and rehabilitation of pipelines is the removal of the original coating system, particularly in cases where the coating contains sticky components or adhesives. It has been found that such coatings can be removed by use of a cleaning machine with a plurality of counter-rotating carbide-tipped tools mounted to an oscillating head embracing the pipe, and which is operable at the same time to travel along the length of the pipe. Such a machine can be designed to effect a positive, gentle milling operation on the pipe surface to remove the coating efficiently and at relatively low power consumption. A particular advantage of the pipe cleaning machine of the invention is that its design and manner of operation allows it to be used in the field to clean an uncovered section of pipeline, for example a natural gas pipeline, without the requirement of removing the pipeline section from the ditch in which it is seated. The machine of the ...
1992-04-28
Optimizing power plant cycling operations while reducing generating plant damage and costs
Energy Technology Data Exchange (ETDEWEB)
This presentation describes a method for analyzing, quantifying, and minimizing the total cost of fossil, combined cycle, and pumped hydro power plant cycling operation. The method has been developed, refined, and applied during engineering studies at some 160 units in the United States and 8 units at the Irish Electric Supply Board (ESB) generating system. The basic premise of these studies was that utilities are underestimating the cost of cycling operation. The studies showed that the cost of cycling conventional boiler/turbine fossil power plants can range from between $2,500 and $500,000 per start-stop cycle. It was found that utilities typically estimate these costs by factors of 3 to 30 below actual costs and, thus, often significantly underestimate their true cycling costs. Knowledge of the actual, or total, cost of cycling will reduce power production costs by enabling utilities to more accurately dispatch their units to manage unit life expectancies, ...
1998-12-31
Energy Technology Data Exchange (ETDEWEB)
This guide explained the requirements for Off-Road Compression Ignition Engine Emission Regulations established under the Canadian Environmental Protection Act. The regulations are enforced by Environment Canada, which authorizes and monitors the use of the national emissions mark. The regulations prescribe standards for off-road engines that operate as reciprocating, internal combustion engines, other than those that operate under characteristics similar to the Otto combustion cycle and that use a spark plug or other sparking device. The regulations apply to engines that are typically diesel-fuelled and found in construction, mining, farming and forestry machines such as tractors, excavators and log skidders. Four different types of persons are potentially affected by the regulations: Canadian engine manufacturers; distributors of Canadian engines or machines containing Canadian engines; importers of engines or machines for the purpose of sale; and persons not in companies importing ...
2006-03-15
International Nuclear Information System (INIS)
This guide explained the requirements for Off-Road Compression Ignition Engine Emission Regulations established under the Canadian Environmental Protection Act. The regulations are enforced by Environment Canada, which authorizes and monitors the use of the national emissions mark. The regulations prescribe standards for off-road engines that operate as reciprocating, internal combustion engines, other than those that operate under characteristics similar to the Otto combustion cycle and that use a spark plug or other sparking device. The regulations apply to engines that are typically diesel-fuelled and found in construction, mining, farming and forestry machines such as tractors, excavators and log skidders. Four different types of persons are potentially affected by the regulations: Canadian engine manufacturers; distributors of Canadian engines or machines containing Canadian engines; importers of engines or machines for the purpose of sale; and persons not in companies importing ...
1999-01-01
Energy Technology Data Exchange (ETDEWEB)
A competitive repopulation assay utilizing chromosome markers was used to assay the reconstituting potential of hematopoietic populations. The test populations consisted of tibial murine marrow locally irradiated with doses ranging from 1.5 Gy to 8.5 Gy and of marrow generated from either murine splenic or marrow stem cells. The purpose of this assay was to assess the innate proliferative potential and microenvironmental influences on the ability to repopulate. Regardless of origin, spleen repopulating ability consistently agreed with spleen colony-forming unit (CFU-s) content. Doses of radiation from 5 Gy to 8.5 Gy diminished, by a factor of 2, the ability to repopulate marrow despite maintenance of CFU-s levels. Marrow generated from splenic stem cells had one-fifth the repopulating ability of marrow derived from marrow stem cells, even though CFU-s levels were equivalent. The results imply that the splenic environment can only maintain stem cells at the level of ...
1988-03-01
Nuclear power plant support activities in reactors chemistry at CNEA
International Nuclear Information System (INIS)
Argentina has two operating PHWR nuclear power plants. Atucha I NPP is a pressure vessel type heavy water reactor of 360 MW e with 25 years of operation and Embalse NPP is a pressure tube type CANDU-600 reactor of 640 MW e. Atucha II, a third plant of 600 MW e of the pressure vessel type similar to Atucha I, is being constructed. NASA (Nucleoelectrica Argentina S.A.) currently operates both nuclear power plants. The National Atomic Energy Commission (Comision Nacional de Energia Atomica - CNEA) provides operational support to the plants, including research and development assistance, and actual technical services and maintenance work in different areas. The Chemistry Department, formerly the Reactor Chemistry Department has carried out project and support activities to the plants during the past 20 years. The aim of this work is to describe the present organization and the activities in reactor chemistry of the Chemistry Department. In particular, the projects to ...
1999-10-15
Nuclear incident monitor criticality alarm instrument for the Savannah River Site: Technical manual
Energy Technology Data Exchange (ETDEWEB)
The Savannah River Site is a Department of Energy facility. The facility stores, processes, and works with fissionable material at a number of locations. Technical standards and US Department of Energy orders, require these locations to be monitored by criticality alarm systems under certain circumstances. The Savannah River Site calls such instruments Nuclear Incident Monitors or NIMs. The Sole purpose of the Nuclear Incident Monitor is to provide an immediate evacuation signal in the case of an accidental criticality in order to minimize personnel exposure to radiation. The new unit is the third generation Nuclear Incident Monitor at the Savannah River Site. The second generation unit was developed in 1979. It was designed to eliminate vacuum-tube circuits, and was the first solid state NIM at SRS. The major design objectives of the second generation NIM were to improve reliability and reduce maintenance costs. Ten prototype units have been built and tested. This ...
1996-05-21
Non-seminomatous testicular germ cell tumours in Denmark 1976-1980. Results of treatment
Energy Technology Data Exchange (ETDEWEB)
Over a 5-year period (1976-1980) 499 patients with non-seminomatous testicular germ cell tumours were included in the Danish Testicular Carcinoma Study (DATECA). The 3-year crude survival for patients in clinical stages I, II and III was 91, 77 and 45 per cent, respectively. In stage I the relapse-free survival for patients given radiation combined with bleomycin and vincristine was significantly higher than that for patients given radiation alone. No difference in the crude survival for patients given radiation combined with bleomycin and vincristine was significantly higher than that for patients given radiation alone. No difference in the crude survival was observed. For stage II patients maintenance chemotherapy following radiation combined with bleomycin and vincristine did not improve relapse-free or crude survival. The survival of patients with non-seminomatous tumours improved significantly during the 5-year period. This improvement was probably due to the ...
1984-01-01
Non-seminomatous testicular germ cell tumours in Denmark 1976-1980
International Nuclear Information System (INIS)
Over a 5-year period (1976-1980) 499 patients with non-seminomatous testicular germ cell tumours were included in the Danish Testicular Carcinoma Study (DATECA). The 3-year crude survival for patients in clinical stages I, II and III was 91, 77 and 45 per cent, respectively. In stage I the relapse-free survival for patients given radiation combined with bleomycin and vincristine was significantly higher than that for patients given radiation alone. No difference in the crude survival for patients given radiation combined with bleomycin and vincristine was significantly higher than that for patients given radiation alone. No difference in the crude survival was observed. For stage II patients maintenance chemotherapy following radiation combined with bleomycin and vincristine did not improve relapse-free or crude survival. The survival of patients with non-seminomatous tumours improved significantly during the 5-year period. This improvement was probably due to the ...
1976-01-01
Energy Technology Data Exchange (ETDEWEB)
Safety and environmental assessments have been made of conceptual fusion power plant designs employing silicon carbide composites (SiC/SiC) as the first wall and blanket structure material. These have used similar analysis methods to earlier studies of designs based on vanadium alloy or low-activation martensitic steel, allowing direct comparisons. The very low short-term activation of silicon carbide results in an almost insignificant level of decay heat in postulated loss of coolant accidents, and a lower {gamma}-dose rate on the timescale of relevance to handling for maintenance operations. However on the longer time-scale, of interest in possible recycling operations, decommissioning and waste management, SiC/SiC appears to perform no better than vanadium alloy or low-activation martensitic steel, due in part to the activation of impurities in a realistic composition. Furthermore, its increased neutron transparency may result in higher activation in the vacuum ...
2001-04-01
Natural gas the new locomotive fuel
Energy Technology Data Exchange (ETDEWEB)
This is a report on modification of a locomotive diesel engine to a dual-fuel engine to determine if the dual fuel engine in railway service will provide high performance, lower fuel and maintenance costs. After the locomotive was modified and the new governor and linkage were installed by General Motors at the BN's Northtown Diesel Shop near Minneapolis, the locomotive went through startup procedures. General Motors participated in startup. Some calibration, adjustments and minor piping changes were required but in general the problems encountered in startups were quite insignificant. The locomotive was connected to the load box (static test) during startup and at 720 RPM exceeded the required output for this test as established by the parties. Operation on straight oil over the range from idle through No. 8 throttle notch and on dual fuel from No. 5 through No. 8 throttle notch was smooth as was the transfer from oil to gas and from gas to oil. The ...
1984-01-01
Energy Technology Data Exchange (ETDEWEB)
The indoor climate of school buildings have been much debated recently. Many problems connected with air quality and thermal comfort are caused by bad maintenance, fitted carpets and no sunshades. Mechanical ventilation in schools has gained a bad reputation and many municipalities are seeking other solutions when building new schools. Natural ventilation according to the ''Swedish model'' does not use air filters or heat recovery from the outgoing air and achieve low energy consumption by reducing the airflow substantially in cold weather. Most of the naturally ventilated schools have supply air culverts of concrete below ground outside the building and in the basement. This is also true of schools using hybrid ventilation, where natural and mechanical ventilation is combined. The naturally ventilated schools often use manual control of the ventilation, which may not always be a good solution for buildings with changing types of ...
2000-07-01
Energy Technology Data Exchange (ETDEWEB)
Demands for electric power system, which include not only minimization of generation cost but also protection of environmental condition and maintenance of transmission security, have been diversified The priority of these objectives may change according to load change, weather, and other conditions. Since these objectives are usually in a trade-off relationship and generally non-commensurable, it is difficult to handle by conventional optimization of a single objective function. This report describes multi-objective scheduling of thermal power system. The adaptability of three performance indicies, such as economic efficiency, NO{sub x} emission, and transmission security, to operators are defined by membership functions in fuzzy set theory. coordinated solution in which the adaptability of operators is maximized can be obtained by maximizing the fuzzy decision-making function composed of the adaptability index for each objective. Because this coordinated solution ...
1992-01-20
Monitoring power plant fireside corrosion using corrosion probes
Energy Technology Data Exchange (ETDEWEB)
The ability to monitor the corrosion degradation of key components in fossil fuel power plants is of utmost importance for Futuregen and ultra-supercritical power plants. Fireside corrosion occurs in the high temperature sections of energy production facilities due to a number of factors: ash deposition, coal composition, thermal gradients, and low NOx conditions, among others. Problems occur when equipment designed for either oxidizing or reducing conditions is exposed to alternating oxidizing and reducing conditions. This can happen especially near the burners. The use of low NOx burners is becoming more commonplace and can produce reducing environments that accelerate corrosion. One method of addressing corrosion of these surfaces is the use of corrosion probes to monitor when process changes cause corrosive conditions. In such a case, corrosion rate could become a process control variable that directs the operation of a coal combustion or coal gasification system. Alternatively, ...
2005-01-01
Energy Technology Data Exchange (ETDEWEB)
The fuel-injection system of the Niigata 6L 16X-AG dual-fuel engine is structured to steadily supply injected fuel during diesel-engine operation, and to distribute oil at a low rate to all the cylinders during gas-engine operation. The dual-fuel engine is started by the diesel engine operation and is changed over to gas-engine operation when the load increases. This change over is done automatically with a link mechanism. Regarding the gas-supply system, the changing pressure of supply gas is controlled by a pressure control valve which is stable and most adequate for the engine. The dual-fuel engine has the following features: (1) a high compression ratio is adopted, which reduces fuel consumption and thermal efficiently; (2) if the supply of gas decreases or stops, while continuing loaded operations, it can immediately shift to diesel engine operation automatically and continue the operation; (3) ignition is done by the injection of pilot oil, thus eliminating ignition failures; and ...
1980-01-01
Material and process improvements in condenser tubing
Energy Technology Data Exchange (ETDEWEB)
The reliability of the surface condenser is a key factor in plant performance level and maintenance cost optimization. This is especially the case for thermal nuclear plants where condenser raw wa-ter ingress can introduce contamination into the chemically-controlled, steam/water loop potentially causing damage to sensitive equipment. Two important parameters must be taken into account when attempting to optimize the quality and the reliability of condenser tubing. They include selecting the appropriate material according to the cooling water corrosion level present. A second and equally important parameter is the manufac-turing of the tubing product itself. This paper will identify methods to optimize manufacturing processes and improve tubing quality, according to VALTIMET's 30 years of condenser welded tubing production experience. Those methods complete the core manufacturing process (forming and welding), through improvement of the metallurgical ...
2010-07-01
In mammals and insects, paracellular blood barriers isolate the nervous system from the rest of the animal. Glia and accessory cells of the nervous system use pumps, channels, cotransporters, and exchangers collectively to maintain the extracellular ion environment and osmotic balance in the nervous system. At present, the molecular mechanisms that regulate this process remain unclear. In humans, loss of extracellular ion and volume regulation in the nervous system poses serious health threats. Drosophila is a model genetic organism with a proven track record for uncovering molecular mechanisms relevant to human health and disease. Here, we review what is known about extracellular ion and volume regulation in larval abdominal nerves, present some new data about the impact of neural activity on the extracellular environment, and relate the findings to mammalian systems. Homologies have been found at the level of morphology, physiology, molecular mechanisms, and mutant phenotypes. The ...
2011-02-08
Long-term corrosion study at nuclear power plant Bohunice (Slovakia)
International Nuclear Information System (INIS)
Steam generators of four VVER-440 units at nuclear power plants V-1 and V-2 in Jaslovske Bohunice (Slovakia) were gradually changed by new original 'Bohunice' design in period 1994-1998. Corrosion processes before and after these design and material changes in Bohunice secondary circuit were studied using Moessbauer spectroscopy during last 25 years. Innovations in the feed water pipeline design as well as material composition improvements were evaluated positively. Moessbauer spectroscopy studies of phase composition of corrosion products were performed on real specimens scrapped from water pipelines or in form of filter deposits. The corrosion of new feed water pipelines system (from austenitic steel) in combination to innovated operation regimes goes dominantly to magnetite. The hematite presence is mostly on the internal surface of steam generator body and its concentration increases towards the top of the body. In the results interpretation it is necessary to consider also erosion ...
2010-03-01
Laboratory ageing of transformer oils
Energy Technology Data Exchange (ETDEWEB)
The insulating oil used in a transformer is a critical component, as its service life is typically 20 years with possibly little or no maintenance. Partial discharges (PD), thermal overloads and static discharges continually subject the oil to chemical deterioration during its operating life. To ensure equipment reliability during service, it is important that the initial quality of the new insulating oil should meet the required acceptance specifications and preferably be pre-tested before use. Accelerated aging tests have been devised to determine the life expectancy of oil in service by using forced air or oxygen flow into the oil, the presence of a copper catalyst, and at elevated temperatures. The more important standards relating to transformer application are discussed and highlights of the more important aspects of the oxidation chemistry of hydrocarbons are included. The ultimate aim of the project is the formulation of better standard testing methods and ...
1996-04-01
Energy Technology Data Exchange (ETDEWEB)
Ejector refrigeration systems are usually designed to utilize low grade energy for driving the cycle. They also have low maintenance cost because they operate without a compressor. Mainly, the ejector performance directly affects the refrigerating performance. Therefore, an investigation on the characteristics and an efficient design of the ejector are important to improve ejector refrigeration systems. In this study, the computational fluid dynamics (CFD) code, FLUENT, is employed to predict the flow phenomena and performance of CPM and CMA steam ejectors. The ejector refrigeration system, using water as the working fluid, is operated at 120-140 C boiler temperature and 5-15 C evaporator temperature. CFD can predict ejector performance very well and reveal the effect of operating conditions on an effective area that is directly related to its performance. Besides, it is found that the flow pattern does not depend much on the suction zone because the results of ...
2007-09-15
Energy Technology Data Exchange (ETDEWEB)
Work on this coke oven gas cleaning demonstration project (CCT-II) this quarter has been focused on Phase IIB tasks, and include engineering, procurement, construction, and training. Additionally, plans for changes in the operating schedule of the coke plant that affect the demonstration project are described. Engineering efforts are nearly complete. Remaining to be finalized is an assessment of electrical heat tracing/insulation needs for pipe lines, assessment of fire protection requirements, and instrument modifications. Procurement of all major equipment items is complete, except for possible additions to fire fighting capabilities. Major focus is on expediting pipe and structural steel to the project site. Civil construction is complete except for minor pads and bases as required for pipe supports, etc. Erection of the hydrogen sulfide and ammonia scrubber vessels is complete. Installation of scrubber vessel internals is underway. A subcontractor has been retained to develop a ...
1993-10-22
Energy Technology Data Exchange (ETDEWEB)
This paper is a result of a research with the primary purpose of extending Probabilistic Risk Assessment (PRA) modeling frameworks to include the effects of organizational factors as the deeper, more fundamental causes of accidents and incidents. There have been significant improvements in the sophistication of quantitative methods of safety and risk assessment, but the progress on techniques most suitable for organizational safety risk frameworks has been limited. The focus of this paper is on the choice of 'representational schemes' and 'techniques.' A methodology for selecting appropriate candidate techniques and their integration in the form of a 'hybrid' approach is proposed. Then an example is given through an integration of System Dynamics (SD), Bayesian Belief Network (BBN), Event Sequence Diagram (ESD), and Fault Tree (FT) in order to demonstrate the feasibility and value of hybrid techniques. The proposed hybrid approach ...
2009-05-15
British Library Electronic Table of Contents (United Kingdom)
Aims: The present study explored the integrative effect of genes encoding methadone pharmacokinetic and pharmacodynamic pathways on methadone maintenance doses in Han Chinese Patients. Materials & methods: Genomic DNA was extracted from 321 opioid-dependent patients and 202 healthy controls, and realtime-PCR and PCR-RFLP were conducted to determine the genotypes. Results: Pair-wise comparisons revealed that carriers of the variants ABCB1 3435C>T or CYP2B6 516G>T alleles were more likely to require a higher methadone dose than noncarriers (both p G or 939C>T allele had a two-fold chance of requiring a lower methadone dose than noncarriers (p = 0.001). Proportional odds regression with adjustment of cofactors demonstrated that ...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
The application of fossil fuels and the simultaneous dependency on fuel imports can only be decreased through consequent utilisation of efficient hydro power which is the most efficient way to avoid CO{sub 2} emissions. Only some decades ago hydro power plants were buildings erected according to met technical demands. In the 1990s rethinking started and the new designs took into account ecology and architecture. Maintenance and/or improvement of ecological efficiency play a decisive role. Experts of ecology and environmental protection of different faculties are involved right from the beginning when planning starts in order to obtain a maximum of nature compatibility and to develop efficient ecological accompanying and compensating measures. Landscape is being recultivated sustainably during construction activities in order to offer biota optimum conditions of living. Devices supporting fish migration are state of the art and designed in such a way that even small ...
2010-07-01
Hybrid electric vehicles and electrochemical storage systems - a technology push-pull couple
Energy Technology Data Exchange (ETDEWEB)
In the advance of fuel cell electric vehicles (EV), hybrid electric vehicles (HEV) can contribute to reduced emissions and energy consumption of personal cars as a short term solution. Trade-offs reveal better emission control for series hybrid vehicles, while parallel hybrid vehicles with different drive trains may significantly reduce fuel consumption as well. At present, costs and marketing considerations favor parallel hybrid vehicles making use of small, high power batteries. With ultra high power density cells in development, exceeding 1 kW/kg, high power batteries can be provided by adapting a technology closely related to consumer cell production. Energy consumption and emissions may benefit from regenerative braking and smoothing of the internal combustion engine (ICE) response as well, with limited additional battery weight. High power supercapacitors may assist the achievement of this goal. Problems to be solved in practice comprise battery management to assure equilibration ...
1999-12-01
High quality water supply system; Joshitsusui kyokyu system
Energy Technology Data Exchange (ETDEWEB)
This paper, firstly, introduces the background in developing a high quality water supply system, in which the drinking water system is isolated inside a building. Results of questionnaire on the high quality service water are illustrated. The results of questionnaire have revealed that the high quality service water is extremely interested. Then, are described the target quality of high quality water, the constitution of high quality water supply system, the treatment process, the measures to secure safety and sanitary, and the method of maintenance. The high quality water is produced through the activated charcoal absorption treatment, membrane treatment, ozonation, cooling, mineral addition, and disinfection of city water. Furthermore, application examples of this system adopted to a department store and a bachelor apartment house are introduced. For the high quality water supply system in the department store, the activated charcoal treatment was employed. For ...
1995-01-15
Energy Technology Data Exchange (ETDEWEB)
Test Area North (TAN) was a site of the Aircraft Nuclear Propulsion (ANP) Project of the U.S. Air Force and the Atomic Energy Commission. Its Cold War mission was to develop a turbojet bomber propelled by nuclear power. The project was part of an arms race. Test activities took place in five areas at TAN. The Assembly & Maintenance area was a shop and hot cell complex. Nuclear tests ran at the Initial Engine Test area. Low-power test reactors operated at a third cluster. The fourth area was for Administration. A Flight Engine Test facility (hangar) was built to house the anticipated nuclear-powered aircraft. Experiments between 1955-1961 proved that a nuclear reactor could power a jet engine, but President John F. Kennedy canceled the project in March 1961. ANP facilities were adapted for new reactor projects, the most important of which were Loss of Fluid Tests (LOFT), part of an international safety program for commercial power reactors. Other projects ...
2005-02-01
Guidelines for indoor air hygiene in school buildings
Energy Technology Data Exchange (ETDEWEB)
The new guidelines for indoor air hygiene in school buildings are intended as a response to current requirements in school practice. The recommendations aim to help to avoid mistakes in modernising school buildings and to provide hygiene-specific support in planning of new school buildings. The guidelines are laid out as follows: (a) In the general section the targets of the guidelines and the target groups are addressed. The current indoor hygiene situation in German schools is described, followed by the parameters with regard to peripheral issues which will not be dealt with further; (b) Part A deals with the hygiene requirements in the practical running of schools. Besides general requirements for maintenance and operation the important issues of cleaning and ventilation are considered, as well as minor building works; (c) Part B provides an overview of important chemical and biological contaminants in schools; (d) Part C looks at building and air conditioning ...
2008-08-15
Good practice and successful experience of cooperation at Daya Bay and Ling Ao
International Nuclear Information System (INIS)
Electricite de France, (EDF) in the late sixties and China through 10. 5-year Plan adopted the same approach of standardized NPPs to benefit from the series effect and to increase and speed up self reliance and localization. This approach also allows to continuously gather the feedback from design, construction and operation and to use it to constantly improve future and present nuclear power plants, by optimizing design features, construction phase and generation performances for safety, quality, cost and schedule aspects. Daya Bay NPP put into commercial operation in 1994 is posting high level safety and operation results. At Ling Ao NPP Chinese engineers of LANPC, with the contribution of the Chinese industry, have efficiency and successfully managed engineering, construction and operation preparation. GNPJVC / LANPC and EDF are developing permanent and mutual experience feedback exchanges in all areas of engineering, maintenance and operation. The results of ...
Gas turbines in cement plants; Erfahrungen aus dem Einsatz von Gasturbinen in einem Zementwerk
Energy Technology Data Exchange (ETDEWEB)
Burner nozzles were often redesigned in order to improve flow design and manufacturing quality. Maintenance intervals, however, are not satisfactory for the operators of such plants. There is no definitive answer as to whether upgraded design allows to lengthen these intervals or whether additional measures are required. Gas turbines may break down for a large number of reasons. This article shows that many of the causes of operational failure and damage are preventable. Damage management will be successful if manufacturers, operators and independent institutions work together.(orig.) [German] Es wurden in der Vergangenheit mehrfach Veraenderungen an den Brennerduesen vorgenommen. Dabei wurden Verbesserungen in der stroemungstechnischen Auslegung und der Fertigungsqualitaet erzielt. Die derzeit noch gueltigen Wartungsintervalle sind fuer den Betreiber unbefriedigend. Inwieweit diese Intervalle mit der modifizierten Ausruestung verlaengert werden koennen oder ob ...
1998-07-01
Gas Research Institute wetland research program
Energy Technology Data Exchange (ETDEWEB)
As part of three ongoing research projects, the Gas Research Institute (GRI) is studying the natural gas industry's impacts on wetlands and how to manage operations so that impacts can be minimized or eliminated. The objective of the first project is to gain a better understanding of the causes and processes of wetland loss in the Louisiana deltaic plain and what role gas pipeline canals play in wetland loss. On the basis of information gathered from the first projects, management and mitigation implications for pipeline construction and maintenance will be evaluated. The objective of the second project is to assess the floral and faunal communities on existing rights-of-way (ROWs) that pass through numerous types of wetlands across the United States. The emphasis of the project is on pipelines that were installed within the past five years. The objective of the third project is to evaluate the administrative, jurisdictional, technical, and economic issues ...
1992-01-01
Full autonomous monitoring tools inside nuclear reactor building
Energy Technology Data Exchange (ETDEWEB)
In this paper, we define, design and test a radiation tolerant autonomous monitoring tool for nuclear embedded applications. The goal of the instrumentation system was to record the values of some parameters such as dose, temperature or vibrations appearing inside the containment building of nuclear power plants. The knowledge of these parameters will be a good help for predictive maintenance of the power plant components. For the design of the monitoring tool, we rely on commercial-off-the-shelf (COTS) low power electronic components to use battery-supplied power. A large amount of components starting from discrete transistors or logic units to memories and micro-controllers was associated to define and design a prototype. We then confirm the environment conditions tolerance estimated to up to 2 kGy of total dose and 80 C for temperature by on-line irradiation experiments for individual components and functions and prototypes. Two different sets of about 60 ...
2009-07-01
Fuels and materials testing capabilities in Fast Flux Test Facility
Energy Technology Data Exchange (ETDEWEB)
The Fast Flux Test Facility (FFTF) reactor, which started operating in 1982, is a 400 MWt sodium-cooled fast neutron reactor located in Hanford, Washington State, and operated by Westinghouse Hanford Co. under contract with U.S. Department of Energy. The reactor has a wide variety of functions for irradiation tests and special tests, and its major purpose is the irradiation of fuel and material for liquid metal reactor, nuclear reactor and space reactor projects. The review first describes major technical specifications and current conditions of the FFTF reactor. Then the plan for irradiation testing is outlined focusing on general features, fuel pin/assembly irradiation tests, and absorber irradiation tests. Assemblies for special tests include the material open test assembly (MOTA), fuel open test assembly (FOTA), closed loop in-reactor assembly (CLIRA), and other special fuel assemblies. An interim examination and maintenance cell (FFTF/IEM cell) and other hot ...
1989-07-01
Fuels and materials testing capabilities in Fast Flux Test Facility
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF) reactor, which started operating in 1982, is a 400 MWt sodium-cooled fast neutron reactor located in Hanford, Washington State, and operated by Westinghouse Hanford Co. under contract with U.S. Department of Energy. The reactor has a wide variety of functions for irradiation tests and special tests, and its major purpose is the irradiation of fuel and material for liquid metal reactor, nuclear reactor and space reactor projects. The review first describes major technical specifications and current conditions of the FFTF reactor. Then the plan for irradiation testing is outlined focusing on general features, fuel pin/assembly irradiation tests, and absorber irradiation tests. Assemblies for special tests include the material open test assembly (MOTA), fuel open test assembly (FOTA), closed loop in-reactor assembly (CLIRA), and other special fuel assemblies. An interim examination and maintenance cell (FFTF/IEM cell) and other hot ...
Financing Projects That Use Clean Energy Technologies: An Overview of Barriers and Opportunities
Energy Technology Data Exchange (ETDEWEB)
Project finance is asset-based financing, meaning that the project lenders have recourse only to the underlying assets of a project. It involves both debt and equity, where the debt-to-equity ratio is typically large (e.g., 70% debt to 30% equity). Debt is used when available and when it is the least expensive form of financing, with equity still needed for credit worthiness. Most important, revenue from the project must be able to generate a return to the equity investors, and pay for interest and principal on the debt, transaction costs associated with developing and structuring the project, and operations and maintenance costs. Successful project financing must provide a structure to manage and share risks in an optimal way that benefits all participants, allocating risks to those entities that are able to mitigate each specific risk, and to share information about putting risk management in the proper hands at the proper stage of project development. ...
2005-10-01
Final report on electric vehicle activities, September 1991--October 1994
Energy Technology Data Exchange (ETDEWEB)
The data and information collected for the Public Service Electric and Gas Company`s (PSE&G) electric vehicle demonstration program were intended to support and enhance DOE`s Electric and Hybrid Vehicle Site Operator Program. The DOE Site Operator Program is focused on the life cycle and reliability of Electric Vehicles (EVs). Of particular interest are vehicles currently available with features that are likely to be put into production or demonstrate new technology. PSE&G acquired eight GMC Electric G-Vans in 1991, and three TEVans in 1993, and conducted a program plan to test and assess the overall performance of these electric vehicles. To accomplish the objectives of DOE`s Site Operator`s test program, a manual data collection system was implemented. The manual data collection system has provided energy use and mileage data. From September 1991 to October 1994 PSE&G logged 69,368 miles on eleven test vehicles. PSE&G also demonstrated the EVs to diverse groups and ...
1995-02-01
Energy Technology Data Exchange (ETDEWEB)
The purpose of this solar energy project was to design, manufacture, install, maintain and evaluate solar heating systems in order to stimulate community acceptance of the practicality of solar applications, reduce non-renewable energy resource consumption, and decrease residential expenditures for energy. The project also provided skill training and experience for CETA employees in the design, manufacture, and installation of solar energy equipment systems. CDC's contract had four separate solar energy projects; namely: Domestic Water Heating Systems for four Single-Family Homes; Domestic Water Heating for an industrial building; Domestic Water Heating for a (4) unit apartment complex (includes (12) supplemental space heating units); and Integral Passive Water Heaters and Energy Conservation Devices for (8) one bedroom homes. CDC staff designed all solar systems and CETA trainees (County and City vocational training program enrollees) under staff guidance manufactured, ...
1983-10-19
Energy Technology Data Exchange (ETDEWEB)
The subject of FDD (fault detection and diagnosis) has gained widespread industrial interest in machine condition monitoring applications. This is mainly due to the potential advantage to be achieved from reduced maintenance costs, improved productivity and increased machine availability. This paper presents a new FDD scheme for condition machinery of an industrial steam turbine using a data fusion methodology. Fusion of a SVM (support vector machine) classifier with an ANFIS (adaptive neuro-fuzzy inference system) classifier, integrated into a common framework, is utilized to enhance the fault detection and diagnostic tasks. For this purpose, a multi-attribute data is fused into aggregated values of a single attribute by OWA (ordered weighted averaging) operators. The simulation studies indicate that the resulting fusion-based scheme outperforms the individual SVM and ANFIS systems to detect and diagnose incipient steam turbine faults. (author)
2010-12-15
Energy Technology Data Exchange (ETDEWEB)
This report provides an assessment of the designs of turret and swivel systems for floating production, storage and offloading (FPSO) vessels and floating storage Units (FSU) which are either purpose built or converted from tankers. Use of FPSO and FSO in the North Sea with the move to subsea and deepwater production is discussed, and the background to FPSO and FSU turret systems is traced. Details are given of general issues relating to ship structure, systems affecting the turret, swivel systems, mooring systems, turret loading, scaffolding and support structure, on-board personnel, and construction standards. Turret system components and types are described, and failure modes, operation and safety relevant components are examined. Inspection and maintenance, examples of good and poor practice, and applicable regulations are considered. Annexes list UK installations and present information on individual turret design, fluid transfer systems, system manufacturers, ...
2002-07-01
FFTF fission gas monitor computer system
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF) is a liquid-metal-cooled test reactor located on the Hanford site. A dual computer system has been developed to monitor the reactor cover gas to detect and characterize any fuel or test pin fission gas releases. The system acquires gamma spectra data, identifies isotopes, calculates specific isotope and overall cover gas activity, presents control room alarms and displays, and records and prints data and analysis reports. The fission gas monitor system makes extensive use of commercially available hardware and software, providing a reliable and easily maintained system. The design provides extensive automation of previous manual operations, reducing the need for operator training and minimizing the potential for operator error. The dual nature of the system allows one monitor to be taken out of service for periodic tests or maintenance without interrupting the overall system functions. A built-in calibrated gamma source can be ...
FFTF [Fast Flux Test Facility] cesium trap design, installation, and operating experience
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF) is a 400-MWt, sodium-cooled reactor located on the Hanford Site near Richland, Washington, USA. The FFTF is owned by the U.S. Department of Energy and is operated by the Westinghouse Hanford Company. The FFTF was designed to test fuels and materials for use in liquid metal reactors. Since initial operation in 1982, anticipated breaches of experimental fuel pins have released fission products, including cesium, into the primary sodium. Because of its high volatility, cesium vaporizes into the cover gas space, where it condenses on components and equipment and is transported into the cover gas outlet. Because of the long half-life of "1"3"7Cs, these deposits result in long-term, local radiation levels that make contact maintenance difficult. Thus, a cesium trap was installed in FFTF to reduce the cesium level in the sodium. The trap could also permit a Run Beyond Cladding Breach (RBCB) program without compromising the sodium purity. ...
1988-10-17
Evaluation of a solid hydrophone cable
Energy Technology Data Exchange (ETDEWEB)
In marine seismic exploration, an approximately two-mile long hydrophone cable is towed behind the ship. The commonly employed cable consists of a kerosene-filled hose enclosing hydrophones, electrical wires, and steel ropes. The kerosene provides buoyancy while the steel ropes are for structural support. For deep-water operations, the cable is pulled through the water at a depth of 20-40 feet. For shallow water, a bottom reference configuration is used and the cable is dragged. This paper presents a comparison of electroacoustic properties between a newly designed, buoyant solid cable and those of the conventional kerosene-filled hose. The emphasis is on drag cable operations. Cable maintenance is a major problem. Jacket cuts occur because of improper handling or collisions with other ships, subsea structures, and debris. Kerosene leakage causes buoyancy loss and the need for immediate replacement. Salt water intrusion causes electrical shorts. Replacement rates ...
1982-07-01
European multicentre evaluation of the Super Aution SA-4220 urinalysis analyser.
A multicentre evaluation of the urine test strip analyser Super Aution-4220 was carried out in six laboratories. The analytical performance of the instrument with regard to imprecision, linearity, detection limit, drift, carry-over and method comparison was studied. Using the Aution stick 8 test strip the pH, glucose, protein, ketones, bilirubin, blood, urobilinogen and leukocyte esterase were analysed. Specific gravity measurements were performed by refractive index method. Within-run and between-run imprecision determined at three levels of analyte were good. No carry-over was observed. Obtained results were linear through all the described analytical range. No significant drift was detected. Method comparison with some quantitative methods was performed and showed a good correlation with most of the analytes. The study of interferences showed minor interferences by common therapeutic drugs with the measurement of some analytes. During the assessment period of about 6 months no ...
1998-12-01
Establishment and maintenance of a coal sample bank and data base
Energy Technology Data Exchange (ETDEWEB)
For each sample, one 30-gallon drum containing approximately 90 lb of coal at {minus}1/4 inch was designated for headspace oxygen analysis and coal quality monitoring at yearly intervals. Headspace oxygen analysis and retrieval of a 5-lb sample for coal analysis have begun. Headspace oxygen contents are shown in Table 1. Preparation and analysis of these samples for the second yearly quality evaluation is in progress. We have initiated a study of different means of storage in preventing sample deterioration and in maintaining an inert headspace atmosphere. The work was performed with support from the Penn State Cooperative Program in Coal Research. A run-of-mine sample of medium-volatile bituminous Lower Kittanning coal was collected as PSOC-1536 and promptly processed. Gieseler fluidity FSI, alkali extraction and preparation of petrographic pellets were accomplished within 32 hours of extraction of the coal from the mine face. Splits of the sample were sealed under argon in several ...
1989-11-16
Energy Technology Data Exchange (ETDEWEB)
The presence of iron and manganese in underground water due to rock leaching may cause problems in drinking water. the oxidation of these metals produces precipitates which alter water quality (by making it cloudy and bad testing) and may even block supply pipes. This article presents a way eliminating this problem which was tried out in the conduits of Cantillana, a municipality in the province of Seville, Spain. Cleaning the pipes with a mixture of H{sub 2}O{sub 2} + water changes the characteristics of the deposits from flocculant and absorbent to sandy following which they are washed away by the pressure of the water. Once the pipes have been cleaned, a minimal amount of maintenance will prevent the formation of new deposits. This article thus a relatively simple and economical solution for recovering water quality as an alternative to the complicated replacement of the whole network. (Author) 7 refs.
1998-12-01
International Nuclear Information System (INIS)
Gas Distribution Companies have long paid great attention to improving the quality of gas supply service to the consumer. This has involved them in an on-going attempt to successfully define and establish a clear computer assisted replacement programme which, when drawn up on a reliability basis, may also prove cost effective. The reasons which drive any gas line replacement programme are mainly related to the necessity: to improve the gas network asset so as to face a striking expected growth in gas demand; to refurbish old distribution systems with the purpose not only to increase the reliability and continuity of gas supply but also to reduce the rate of maintenance costs due to frequent repair works; to prevent the possibility of massive replacement works for a progressing ageing of the network. This paper will present the computer assisted procedure being implemented by Italgas. It ranks well defined network areas which urgently need renewal and also have a ...
1997-06-10
ESR/Alanine dosimetry on Wolsung Unit 1
Energy Technology Data Exchange (ETDEWEB)
Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement result shows extremely high radiation level in few points of ...
2007-07-01
ESR/Alanine dosimetry on Wolsung Unit 1
International Nuclear Information System (INIS)
Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement result shows extremely high radiation level in few points of ...
2007-05-10
Diagnosing mechanical changes: A test of the machine condition monitoring concept
Energy Technology Data Exchange (ETDEWEB)
BC Hydro recently conducted a demonstration test of a bearing condition monitor. The test, at the 529-MW Kootenay Canal project, proved the ability of the monitor to detect machine condition faults. The capability to detect changing conditions during normal operation of hydroelectric machines gives hydro plant owners the opportunity to anticipate needed maintenance and ultimately to reduce the number of equipment failures. BC Hydro intends to install bearing condition monitors, as well as windings monitors, brushgear monitors, environmental monitors, and other selected systems in as many as 46 of its hydro generators. BC Hydro analyzed forced outages between 1985 and 1989 in its hydro system to identify which parts of a generating unit resulted in the highest number of hours of outage. From there, the utility has formulated a concept for a machine condition monitoring system. To keep the system cost effective, it will be developed in modules. In this way, users can ...
1993-05-01
Development of a best estimate auditing code for CANDU thermal hydraulic safety analysis
Energy Technology Data Exchange (ETDEWEB)
The main purpose of this study is to develop a thermal hydraulic auditing code for the CANDU reactor, modifying the model of existing PWR auditing tool , i.e. RELAP5/MOD3. This scope of project is a fourth step of the whole project, applying the RELAP5/MOD3/CANDU+ version for the real CANDU plant LOCA Analysis and D2O leakage incident. There are three main models under investigation, i.e. Moody critical flow model, flow regime model of horizontal CANDU bundle, and fuel element heatup model when the stratification occurs, especially when CANDU LOCA is tested. Also, for Wolsung unit 1 D2O leakage incident analysis, the plant behavior is predicted with the newly developed version for the first 1000 seconds after onset of the incident, with the main interest aiming for system pressure, level control system, and thermal hydraulic transient behavior of the secondary system. The model applied for this particular application includes heat transfer model of nuclear fuel assembly, decay heat ...
2001-03-01
Energy Technology Data Exchange (ETDEWEB)
A program is currently in progress at Argonne National Laboratory to evaluate and develop evaporator technology for concentrating radioactive waste streams. By concentrating radioactive waste streams, disposal costs can be significantly reduced. To effectively reduce the volume of waste, the evaporator must achieve high decontamination factors so that the distillate is sufficiently free of radioactive material. One technology that shows a great deal of potential for this application is being developed by LICON, Inc. In this program, Argonne plans to apply LICON`s evaporator designs to the processing of radioactive solutions. Concepts that need to be incorporated into the design of the evaporator include, criticality safety, remote operation and maintenance, and materials of construction. To design an effective process for concentrating waste streams, both solubility and vapor-liquid equilibrium data are needed. The key issue, however, is the high decontamination ...
1993-10-01
Energy Technology Data Exchange (ETDEWEB)
A survey to assess the techniques used to control occupational exposure to formaldehyde (50000) and methanol (67561) was conducted at the E. I. DuPont de Nemours and Company (SIC-2869) formaldehyde production unit, Linden, New Jersey, in October 1982. Exposure concentrations were reduced primarily by the use of a process that was completely enclosed except for process sampling, methanol unloading, and formaldehyde discharge points. Local and area exhaust ventilation, and work practices were also used to control exposures. Formaldehyde concentrations in the absorber area were controlled by burning the exit gases in an afterburner and discharging them high above the ground. Analysis of area and breathing zone samples showed methanol and formaldehyde concentrations below the OSHA limits of 200 and 3 parts per million, respectively. The authors conclude that workers are not overexposed to either methanol or formaldehyde on a short or long term basis. Maintenance ...
1983-09-01
Designing a healthy house - an overview
Energy Technology Data Exchange (ETDEWEB)
There are certain factors to take into account when determining the suitability of a healthy house site. Power lines, agricultural spraying, vehicle exhaust, and industrial pollution are all potential sources of indoor air contamination. It is recommended that a environmental assessment be done to determine whether there are specific sources of contamination. Good drainage is required. The surrounding landscaping should be open and sunlit, and with low maintenance requirements. Decks and fences made from pressure-treated or chemical treated lumber should be avoided. One of the early decisions in the design process is the choice of the structural system. The key with all foundation types is to control moisture, whether from rain, from the ground, or the condensation of moisture from the air with cooling. The construction frame is sealed away from the occupants by the air/vapor barrier, so only in extreme cases is it essential to use alternatives to softwood lumber ...
1999-11-01
Design of pilot-scale constructed wetlands for tertiary treatment of refinery effluent
Energy Technology Data Exchange (ETDEWEB)
Two pilot-scale constructed wetlands (4:1 length:width aspect) were designed for tertiary treatment of refinery effluent. As requirements for removal of contaminants from NPDES effluents become more stringent, cost-effective technological approaches are needed to achieve the necessary treatment levels and be efficient, effective and low maintenance. The fundamental design of these constructed wetlands was based on biogeochemical principles that regulate the fate and persistence of the targeted elements (Cu, Zn, Pb). In order to maximize opportunities to learn more about the internal function of the wetlands, they were built to operate in series or in parallel permitting hydraulic retention times of 24 to 48 hours. The wetlands were lined with {approximately}76 cm of compacted clay as well as a 30 mil polyethylene liner. The hydrosoil selected for use in the constructed wetlands is 74.1% sand, 25.6% silt, 0.3% clay. Based on laboratory studies, this hydrosoil ...
1994-12-31
Design modifications in 540 MWe and its impact on the dose rates
International Nuclear Information System (INIS)
Exposure control at the operating Nuclear Power Station is a major concern. TAPS Unit-4 is the first Pressurized Heavy Water Reactor of 540 MWe electrical capacity. This unit was made critical on March 6, 2005. In-depth review of radiation safety was done to identify the impact of design modification on dose rates at various locations and on the equipment's. Problems encountered in controlling the dose rates in 220 MWe electrical are eliminated by appropriate design modifications. Due to higher capacity of the unit there are design changes in major systems such as reactor core, primer heat transport system, moderator system, reactor regulation and protection systems. Reactor operations and maintenance activities during shut down contributes to exposure of the employees. Based on the experience gained in the operation of 220 MWe, design modifications incorporated in TAPS unit-4 and dose rate measurements carried out at 90 % full power, through this paper attempt is ...
2005-11-23
Department of Energy: Privacy Act; records maintained on individuals. [Federal Register entry
Energy Technology Data Exchange (ETDEWEB)
These regulations establish procedures for the administration of the Privacy Act of 1974 by the Department of Energy (DOE). Included are standards of conduct for DOE employees under the Privacy Act, procedures by which individuals may exercise their Privacy Act rights with regard to DOE systems of records, conditions of disclosure for DOE records subject to the Privacy Act, and provisions regarding the establishment and maintenance of DOE systems of records. These regulations were published in proposed form on May 27, 1980, at 45 FR35764. A detailed discussion of the content and provisions of the regulations, as well as the relationship of the regulations to the Privacy Act regulations of DOE's predecessor agencies (the Federal Energy Administration, the Energy Research and Development Administration, and the Federal Power Commission), was included in the preamble to the proposed regulation. These regulations supersede the Privacy Act regulations of the ...
1980-09-16
Energy Technology Data Exchange (ETDEWEB)
The purpose of this document is to provide the definition and means of maintaining the Safety Envelope (SE) related to the Criticality Alarm System (CAS). This document provides amplification of the Limiting Condition for Operation (LCO) described in the Plutonium Finishing Plant (PFP) Operational Safety Requirements (OSR), WHC-SD-CP-OSR-010, Rev. 0, 1994, Section 3.1.2, Criticality Detectors and Alarms. This document, with its appendices, provides the following: (1) System functional requirements for determining system operability (Section 3); (2) A list of annotated system block diagrams which indicate the safety envelope boundaries (Appendix C); (3) A list of the Safety Class 1 and 2 Safety Envelope (SC-1/2 SE) equipment for input into the Master Component Index (Appendix B); (4) Functional requirements for individual SC-1/2 SE components, including appropriate setpoints and process parameters (Section 6 and Appendix A); (5) A list of the operational, ...
1997-05-13
Energy Technology Data Exchange (ETDEWEB)
The microelectronic cable diagnosis is a substantial tool to determine destruction free the residual strength and the lifetime of laid PE/XLPE medium voltage cables. Fundamentals of the ageing diagnosis and a cost reduced inspection concept are the `Isothermal-Relaxation-Current` Analysis and the Neuro-Fuzzy evaluation software. These new tools are able to determine the ageing status of the investigated cable without any references. The authors also show that the test breakdown during the assessment of the ageing status of criterial systems can be reduced by this approach. The cable diagnosis equipment KDA is also useful for the steering of investment as well as for preventive maintenance. (orig.) [Deutsch] Die zerstoerungsfreie dielektrische Kabeldiagnostik kann heute einen wesentlichen Beitrag zur Bestimmung der Restfestigkeit und der Restlebensdauer eines PE/VPE-isolierten Mittelspannungskabels leisten. Basis der Alterungsdiagnose und des Konzeptes zur ...
1997-12-15
Cost comparison among spent fuel storage techniques
Energy Technology Data Exchange (ETDEWEB)
Scenarios are developed for spent fuel that is taken out of the nuclear reactor and stored for 20 years before reprocessing, and three storage techniques which use a water pool, dry cask or vault are compared with respect to their costs. The storage price (storage cost per kilogram of spent fuel), which is employed as the economic index, is calculated on the assumption that all the charge is paid when the spent fuel is brought in the storage facilities. Four scenarios are assumed for spent PWR and BWR fuels to be stored in at-reactor (AT) or away-from-reactor (AFR) facilities. The capital costs cover the buildings of the storage facilities, equipment, decommissioning, casks for transportation and storage (for cask storage) and casks for transportation (for water pool or vault storage). Costs for operation and maintenance of the facilities are also considered in evaluating these methods. Evaluation results show that the dry cask method is the most advantageous for ...
1987-09-01
Cost comparison among spent fuel storage techniques
International Nuclear Information System (INIS)
Scenarios are developed for spent fuel that is taken out of the nuclear reactor and stored for 20 years before reprocessing, and three storage techniques which use a water pool, dry cask or vault are compared with respect to their costs. The storage price (storage cost per kilogram of spent fuel), which is employed as the economic index, is calculated on the assumption that all the charge is paid when the spent fuel is brought in the storage facilities. Four scenarios are assumed for spent PWR and BWR fuels to be stored in at-reactor (AT) or away-from-reactor (AFR) facilities. The capital costs cover the buildings of the storage facilities, equipment, decommissioning, casks for transportation and storage (for cask storage) and casks for transportation (for water pool or vault storage). Costs for operation and maintenance of the facilities are also considered in evaluating these methods. Evaluation results show that the dry cask method is the most advantageous for ...
Cost analysis of the ownership and use of traditional and innovative cooking appliances
Energy Technology Data Exchange (ETDEWEB)
This study develops a framework for analysis and assessment of the cost of ownership and use of major cooking appliances. This involved an assessment of the monetary cost as well as the cost of human resources required to maintain and operate cooking systems. The goal was to provide information useful in making purchase decisions within a framework that can be used to organize information about cost beyond the initial purchase price. Five cooktops - conventional electric oil, induction, solid element with thermostatic control, solid element with thermal limiter, and gas - and a microwave oven were used to develop a decision-making matrix. Results were used to assign weights in the matrix used to develop a 10-point scale that represented the total cost of owning and using a cooking system in food preparation. Based on the matrix, the microwave oven received the highest score followed by gas, conventional electric coil, solid element with thermostatic control, solid element with thermal ...
1988-01-01
Corrosion failure and its prevention in light water reactor power plants
Energy Technology Data Exchange (ETDEWEB)
During 17 years since the start of operation of the first commercial LWR in Japan, many LWRs have experienced various corrosion damages, but the causes of them were clarified, and the counter-measures were executed effectively in actual plants, as the results, the cause of corrosion damage decreased remarkably, and now, the high rate of operation has become to be maintained. In this paper, the major cases of corrosion damage experienced in LWRs in Japan and foreign countries, the causes of them and the countermeasures, the problems of hereafter and so on are described. The corrosion damage of metallic materials in the environment of LWRs occurs in the parts in contact with high temperature, high pressure water and steam, such as stainless steel piping in the primary cooling system of BWRs, and nickel alloy heating tubes of steam generators, carbon steel feed water piping and zirconium alloy fuel cladding tubes in PWRs. Recently, accompanying the advance of LWR technology, the ...
1988-01-01
Corrosion failure and its prevention in light water reactor power plants
International Nuclear Information System (INIS)
During 17 years since the start of operation of the first commercial LWR in Japan, many LWRs have experienced various corrosion damages, but the causes of them were clarified, and the counter-measures were executed effectively in actual plants, as the results, the cause of corrosion damage decreased remarkably, and now, the high rate of operation has become to be maintained. In this paper, the major cases of corrosion damage experienced in LWRs in Japan and foreign countries, the causes of them and the countermeasures, the problems of hereafter and so on are described. The corrosion damage of metallic materials in the environment of LWRs occurs in the parts in contact with high temperature, high pressure water and steam, such as stainless steel piping in the primary cooling system of BWRs, and nickel alloy heating tubes of steam generators, carbon steel feed water piping and zirconium alloy fuel cladding tubes in PWRs. Recently, accompanying the advance of LWR technology, the ...
Cooperative Research Centre for Mining Technology and Equipment (CMTE) annual report 1998/99
Energy Technology Data Exchange (ETDEWEB)
The Centre's new structure, implemented in July 1997 is now operating well. CMTE Development Limited is now the legal entity for the CRC and replaces the previously unincorporated joint venture. CMTE has ten core participating organisations. Roche Highwall Mining Pty. Ltd., withdrew participation during the year. The annual report describes its structure and management and various cooperative links. It outlines research programs in the following areas: mining; geological sensing; automation; reliability and maintenance; and coal processing. Projects include: developing an ultra-short-radius drilling machine for drainage of methane gas from coal seams; developing techniques for improved drilling speed and accuracy to reduce costs for gas drainage holes in underground coal mining; developing draglines; developing geophysical logging tools; developing autonomous control of underground vehicles such as coal-haul-dump (LHD) and haulage trucks, developing tools ...
1999-07-01
Consequences of warm-up of a sector above 80K
There may be circumstances when a sector has to be partially or totally warmed-up to temperatures above 80 K, that is when thermal dilatation starts to play a role. Some equipment have been identify as presenting a risk, like the non-conform "plug-in" modules in the arcs. Because of motion induced by thermal dilatation, the electrical (ElQA) quality control may also have to be done again after cool-down. The main reason identified so far for partial warm-up is the required maintenance of the cooling towers and the cryogenics plants. There is also the request from the vacuum group to periodically warm-up the beam screen to temperatures in the 100 K region to release and pump-out the gas crysorbed on the surface of the beam screen. Observed and expected temperature conditions and statistics on failures of PIMs in sectors which have been warmed-up will be presented in this contribution. Methods to detect buckled PIMs will be described, as well as a recommended ...
2009-01-01
International Nuclear Information System (INIS)
Energy expenditure (EE) of four adult men on a weight-maintenance diet was estimated by use of doubly labeled water, intake balance, and direct and indirect calorimetry. The doubly labeled water (2H218O) method was used to estimate free-living EE for 13 d. Metabolizable energy (ME) intake was used to estimate free-living EE for 1 wk. The subjects' 24-h EE was measured in a dual direct-indirect room calorimeter on 3 alternate days. Estimates of free-living EE as measured by ME intake and doubly labeled water indicate agreement between the two methods (mean difference +/- SEM, -1.04 +/- 0.63%). Measurements of EE with indirect and direct calorimetry are equivalent (mean difference 0.63 +/- 0.44%). The daily EE measured by doubly labeled water in these free-living adults over a 13-d period was 15.01% greater than the 24-h EE measured within the calorimeter.
Energy Technology Data Exchange (ETDEWEB)
Acid mine drainage is a serious environmental problem caused by the oxidation of sulfide minerals that releases highly acidic, sulfate, and metals-rich drainage. In this study, alkaline industrial wastes were mixed with acid mine tailings in order to obtain neutral conditions. A series of column leaching tests were performed to evaluate the behavior of reactive mine tailings amended with alkaline-additions under dynamic conditions. Column tests were conducted of oxidized mine tailings combined with cement kiln dust, red mud bauxite, and mixtures of cement kiln dust with red mud bauxite. The pH results show the addition of 10% of alkaline materials permits the maintenance of near neutral conditions. In the presence of 10% alkaline material, the concentration of toxic metals such as Al, Cu, Fe, Zn are significantly reduced as well as the number of viable cells (Thiobacillus ferrooxidans) compared to control samples.
2005-08-01
Coal quality engineering analysis aids plant performance
Energy Technology Data Exchange (ETDEWEB)
The Coal Quality Engineering Analysis (CQEA) program developed by the New York State Electric and Gas Company (NYSEC) calculates the as-burned cost of burning a specific coal in a specific generation unit. These costs include: maintenance costs for coal and ash handling equipment; ash disposal costs; cost of oil (if required for flame stability and/or derating because of pulverizer capacity limitation); flue gas desulfurization costs; cost of replacement power caused by pulverizer, precipitator fly ash collection and bottom ash capacity limitation; boiler losses due to moisture, hydrogen, dry gas and unburned carbon; power for coal and ash handling equipment; power for coal pulverizers; cost of using excess air to prevent slagging of coal with low ash softening temperatures; and effect of heat rate on coal tonnage required for a desired generation. The use of CQEA to identify areas in which plant operations may be improved is discussed. 7 figs., 1 tab.
1988-10-01
CleverFarm - A SuperSCADA system for wind farms
Energy Technology Data Exchange (ETDEWEB)
The CleverFarm project started out to build an integrated monitoring system for wind farms, where all information would be available and could be used across the wind farm for maintenance and component health assessments. This would enable wind farm operators to prioritise their efforts, since they have a good view of the farm status from home. A large emphasis was placed on the integration of condition monitoring approaches in the central system, enabling estimates of the remaining lifetime of components, especially in the nacelle. During the 3,5 years of the project, software and hardware was developed and installed in two wind farms in Denmark and Germany. The connected hardware included two different condition monitoring systems based on vibration sensors from Gram&Juhl and ISET, plus a camera system developed by Overspeed. Additionally, short-term predictions of the wind farm output were delivered by DMI and Risoes Prediktor system throughout the ...
2004-08-01
The role of intracellular Ca2+ (Ca2+i) on hematopoiesis was investigated in long term bone marrow cultures using cytokines and agonists of P2 receptors. Cytokines interleukin 3 and granulocyte/macrophage colony stimulator factor promoted a modest increase in Ca2+i concentration ([Ca2+]i) with activation of phospholipase Cgamma, MEK1/2, and Ca2+/calmodulin kinase II. Involvement of protein kinase C was restricted to stimulation with interleukin 3. In addition, these cytokines promoted proliferation (20 times) and an increase in the Gr-1(-)Mac-1+ population with participation of gap junctions (GJ). Nevertheless ATP, ADP, and UTP promoted a large increase in [Ca2+]i, moderate proliferation (6 times), a reduction in the primitive Gr-1(-)Mac-1(-)c-Kit+ population, and differentiation into macrophages without participation of GJ. It is likely that Ca2+i participates as a regulator of hematopoietic signaling: moderate increases in [Ca2+]i would be related to cytokine-dependent proliferation ...
2008-09-05
International Nuclear Information System (INIS)
The CAMDU 6 reactor has an international reputation as one of the world's best performing and safe reactors. CANDU 6 reactors are consistently ranked in the world's top 10 for annual and lifetime performance. Six CANDU 6 units are currently in operation in four continents; in Quebec, New Brunswick, South Korea, Argentina and Romania. There are another two CANDU 6 units currently under construction at wolsong, in Korea which ore scheduled to go into service in 1998 and 1999 respectively. A second CANDU 6 unit is currently being considered for Romania. The construction of two CANDU 6 units at Qinshan, in China, is now underway. The performance of the four first-generation CANDU 6 plants, which have now been in service for 15 years, continue to show very good performance, with capacity factors on average since in-service of over 85%. The annual capacity factor of 10.21% during 1997 has been achieved by the Wolsong-1 unit in South Korea. These high capacity factors have been achieved on a ...
1998-03-23
Breakdowns of high-voltage transmission lines due to sea-salt deposits on insulators
Energy Technology Data Exchange (ETDEWEB)
Until 1990, in Tuscany, salt pollution of anti-salt insulators installed on high-tension transmission lines had led to rare breakdowns. On the contrary, in the last months of 1990, in most of Tuscany, following a strong libeccio wind coming from the Tyrrhenian Sea, and due to a long period of drought, salt deposits accumulated on the insulators of the high-voltage transmission lines (380 kV, 220 kV and 132 kV). This phenomenon not only took place in the coastal areas near Livorno, Pisa and Grosseto, but also in areas far away from the sea such as Florence, Prato, Arezzo and Siena. Following this, several high-tension lines, and whole sections of 380 kV electric stations went out of order, damaging the stations' equipment, insulators on the lines, and in particular porcelain insulators. The maintenance operations that were immediately undertaken consisted in washing operations, first focussed on stations, and then on lines. Several hundred men and some ...
1992-03-01
Breakdowns of high-voltage transmission lines due to sea-salt deposits on insulators
International Nuclear Information System (INIS)
Until 1990, in Tuscany, salt pollution of anti-salt insulators installed on high-tension transmission lines had led to rare breakdowns. On the contrary, in the last months of 1990, in most of Tuscany, following a strong libeccio wind coming from the Tyrrhenian Sea, and due to a long period of drought, salt deposits accumulated on the insulators of the high-voltage transmission lines (380 kV, 220 kV and 132 kV). This phenomenon not only took place in the coastal areas near Livorno, Pisa and Grosseto, but also in areas far away from the sea such as Florence, Prato, Arezzo and Siena. Following this, several high-tension lines, and whole sections of 380 kV electric stations went out of order, damaging the stations' equipment, insulators on the lines, and in particular porcelain insulators. The maintenance operations that were immediately undertaken consisted in washing operations, first focussed on stations, and then on lines. Several hundred men and some helicopters ...
1992-01-01
Applications of a downhole programmable microprocessor for a geothermal borehole inspection tool
Energy Technology Data Exchange (ETDEWEB)
The high-temperature scanning borehole inspection system is currently being developed jointly by the Los Alamos National Laboratory (LANL) and Westfalische Berggewerkschaftskasse (WBK) of West Germany. The downhole instrument is a digital televiewer that utilized a microprocessor to digitize, process and transmit the acoustic information to the surface acquisition and control system. The primary operation of the downhole acoustic assembly uses a piezoelectric crystal acting as a receiver-transmitter which is mounted on the rotating head. The crystal emits a burst of acoustic energy that propagates through the borehole fluid with a portion of the energy reflected by the borehole wall back to the crystal. The time of travel and the amplitude of the reflected signal are conditioned by the microprocessor and transmitted along with other pertinent data to the surface data processing center. This instrument has been designed specifically for use in geothermal borehole environments to ...
1987-01-01
An evaluation of the ecological consequences of partial-power operation of the K Reactor, SRS
International Nuclear Information System (INIS)
The K Reactor at the Savannah River Site (SRS) shut-down in spring 1988 for maintenance and safety upgrades. Since that time the receiving stream for thermal effluent, Indian Grave Branch and Pen Branch, have undergone a pattern of post-thermal recovery that is typical of other SRS streams following removal of thermal stress. Divesity of fish and aquatic macroinvertebrate communities has increased and available habitats have been colonized by numerous species of herbaceous and woody plants. K Reactor is scheduled to resume operation in 1991 and operate through 1992 without a cooling tower to cool the discharge. It is likely that the reactor will operate at approximately one-third to one-half of full power (800--1200 MW thermal) during this period and effluent temperatures will be substantially lower than earlier operation at full power. Monthly average discharge temperatures at half-power operation will range from approximately 42 degrees C in winter to 49 degrees ...
Aerodynamic design of the George Washington University solar car Sunforce 1
Energy Technology Data Exchange (ETDEWEB)
Aerodynamics play a critical role in the success of a competitive solar vehicle. In particular, the topics addressed in this paper are minimizing the drag forces acting on the car surface while providing an effective angle of solar exposure, ventilation, manoeuvring stability, maintenance accessibility, and component `functional duality`, while simultaneously maintaining stringent racing regulations. Starting with a conceptual design, modifications were analysed through a commercial, computational fluid dynamics (CFD) package in order to evaluate drag and lift characteristics. By visualizing wind tunnel flow as a means of support of the coded model, the computational design has been validated. Although the design of the George Washington University (GWU) solar car `Sunforce 1` was geared towards the November 1993 World Solar Challenge held in Australia, results of the fourth place finish in the US Sunrace `93 were used to demonstrate the effectiveness of this ...
1997-05-01
Advanced evaporator technology progress report FY 1992
Energy Technology Data Exchange (ETDEWEB)
This report summarizes the work that was completed in FY 1992 on the program {open_quotes}Technology Development for Concentrating Process Streams.{close_quotes} The purpose of this program is to evaluate and develop evaporator technology for concentrating radioactive waste and product streams such as those generated by the TRUEX process. Concentrating these streams and minimizing the volume of waste generated can significantly reduce disposal costs; however, equipment to concentrate the streams and recycle the decontaminated condensates must be installed. LICON, Inc., is developing an evaporator that shows a great deal of potential for this application. In this report, concepts that need to be incorporated into the design of an evaporator operated in a radioactive environment are discussed. These concepts include criticality safety, remote operation and maintenance, and materials of construction. Both solubility and vapor-liquid equilibrium data are needed to ...
1995-01-01
International Nuclear Information System (INIS)
Many mechanical parts are subjected to stresses and strains that may eventually lead to their failure. In order to prevent the costly delays associated with equipment down-time, many parts have to be tested for weaknesses and defects when machinery is constructed or dismantled for maintenance. These procedures are known as Non-Destructive Testing (NDT) methods. Five types of non-destructive testing methods routinely used are radiographic testing, ultrasonic testing, magnetic particle inspection, liquid penetrant testing and eddy current testing. Out of these five techniques industrial radiography plays an important role in non-destructive testing to reveal interior defects in materials. In radiography almost two-thirds of the radiation reaching the film is scattered radiation which does not form the image of defects. Scattered radiation generated inside and outside a material has a very large effect on sensitivity of flaw detection since it reduces image contrast. ...
1998-02-01
A structured approach to the assessment of the quality culture in nuclear installation
International Nuclear Information System (INIS)
INSAG has emphasized that safety culture has two general components: the organizational framework and the attitude of the staff. To develop a structured approach to the assessment of safety culture, we propose that the highly formalized nature of nuclear power plant organizations be exploited. The prime coordinating mechanism of NPP organizations is the standardization of work processes, where a work process is defined as a standardized sequence of tasks designed to achieve a specific goal (an example is the maintenance work process). The predictable nature of work processes is exploited by the Work Process Analysis Model (WPAM) to conduct a systematic analysis that identifies the desirable characteristics of work processes and develops performance measures for their strengths and weaknesses. These can provide a set of tangible characteristics of a good safety culture. It is argued in this paper that the analysis of normal power production and investment protection ...
1995-04-01
Energy Technology Data Exchange (ETDEWEB)
Today`s nuclear power plants are marked by increasing needs for non-destructive inspection techniques in preventive maintenance programs. Additionally, it is becoming more important to evaluate residual stress which may be a key parameter for crack propagations in welded pipings. The authors have developed an ultrasonic velocity measurement method which obtains ultrasonic velocity changes by residual stress with a high accuracy. The ultrasonic velocity measurement is composed of three procedures. They are as follows. (1) Highly accurate propagation time measurements; (2) Pipe thickness correction; (3) Residual stress evaluation. The ultrasonic velocity measurements have been applied to the residual stress evaluation of carbon steel welded pipings. Destructive testing using stress strain gauges was done after the ultrasonic non-destructive evaluation of the residual stress. The experimental results verified that residual stress in carbon steel welded pipings can be ...
1995-08-01
British Library Electronic Table of Contents (United Kingdom)
PurposeWe investigated the efficacy and safety of degarelix treatment and the effects of switching from leuprolide to degarelix in an ongoing extension study with a median 27.5-month followup of a pivotal 1-year prostate cancer trial. Materials and MethodsPatients who completed a 1-year pivotal phase III trial continued on the same monthly degarelix maintenance dose (160 or 80 mg in 125 each), or were re-randomized from leuprolide 7.5 mg to degarelix 240/80 mg (69) or 240/160 mg (65). Data are shown on the approved degarelix 240/80 mg dose. The primary end point was safety/tolerability and the secondary end points were testosterone, prostate specific antigen, luteinizing hormone and follicle-stimulating hormone responses, and prostate specific antigen failure and progression-free survival....
2011-01-01
White Rose oilfield development application. CD-ROM ed.
Energy Technology Data Exchange (ETDEWEB)
Located approximately 350 km east of Newfoundland, on the eastern edge of the Jeanne d'Arc Basin, and approximately 50 km from both the Terra Nova and Hibernia oilfields, the White Rose oilfield is considered the main oil producing basin off the eastern coast of North America. Husky Oil is very active in the region and holds almost 32 per cent net working interest in the Significant Discovery License areas in the Jeanne d'Arc basin. The development of an economically significant oil discovery in the White Rose Significant Discovery Area is being proposed jointly by Husky Oil and Petro-Canada. It is estimated that the project would enable the recovery of an estimated 36 million cubic meters (230 million barrels) of recoverable oil in this area that covers approximately 40 square kilometers. The operators propose to use a ship-shaped floating production, storage and offloading (FPSO) facility which could store up to 135,000 cubic meters (850,000 barrels) of oil or the ...
2001-01-01
Innovative Structural and Joining Concepts for Lightweight Design of Heavy Vehicle Systems
Energy Technology Data Exchange (ETDEWEB)
The extensive research and development effort was initiated by the U.S. Department of Energy (DOE) in 2002 at West Virginia University (WVU) in order to investigate practical ways of reducing the structural weight and increasing the durability of heavy vehicles through the judicious use of lightweight composite materials. While this project was initially focused on specific Metal Matrix Composite (MMC) material, namely Aluminum/Silicon Carbide (Al/SiC) commercially referenced as ''LANXIDE'', the current research effort was expanded from the component level to the system level and from MMC to other composite material systems. Broadening the scope of this research is warranted not only by the structural and economical deficiencies of the ''LANXIDE'' MMC material, but also by the strong coupling that exists between the material and the geometric characteristics of the structure. Such coupling requires a truly ...
2006-09-30
Energy Technology Data Exchange (ETDEWEB)
Fisheries co-managers of U.S. v Oregon supported and directed the construction and operation of acclimation and release facilities for Snake River fall Chinook from Lyons Ferry Hatchery at three sites above Lower Granite Dam. In 1996, Congress instructed the U.S. Army Corps of Engineers (USCOE) to construct, under the Lower Snake River Compensation Plan (LSRCP), final rearing and acclimation facilities for fall Chinook in the Snake River basin to complement their activities and efforts in compensating for fish lost due to construction of the lower Snake River dams. The Nez Perce Tribe (NPT) played a key role in securing funding and selecting acclimation sites, then assumed responsibility for operation and maintenance of the facilities. In 1997, Bonneville Power Administrative (BPA) was directed to fund operations and maintenance (O&M) for the facilities. Two acclimation facilities, Captain John Rapids and Pittsburg Landing, are located ...
2004-01-01
Development of Guide System for a Reactor Head Maintenance Robot
Energy Technology Data Exchange (ETDEWEB)
The Control Rod Drive(CRD) nozzles for PWR nuclear power plants(NPP) house the control rod drives. The number of nozzle penetrations range from the mid-30's to over 100 in each reactor head. The integrity of CRD nozzles is very important, because the primary pressure boundary is established with the J-groove weld joining the nozzle to the head clad surface. The Alloy 600 PWSC CRD nozzle leaks discovered in the fall of 2000 and spring of 2001 in several US plants. Therefore the NRC has recommended a more proactive effort by US utilities to inspect similarly susceptible nozzles in all US plants. The primary safety concern is circumferential cracks that can permit the nozzles to separate from the head at high velocity and produce a large-break leak in the reactor vessel. A secondary concern is head leakage from any through-wall cracks in the nozzle or J-groove weld area. Numerous inspection and repair tools have been developed to address CRD nozzle inspection and repair issues. ...
2005-07-01
Status of steam generators in Spain
International Nuclear Information System (INIS)
There are a total of nine operational nuclear plants in Spain totalling 7.350 MWe. These units produced 54.265 x 106 KWh in 1990, 36% of the total generation in Spain. Seven of these plants are of the PWR type. The first plant in operation was Jose Cabrera (ZORITA) in 1968, one loop Westinghouse plant with a model 24 Steam Generator. Due to the design margin and careful operation of the Steam Generator of this plant its performance have been very good, with only 5% tubes plugged after 23 years of operation. This is one of the few units in the world that remains in phosphate chemistry. During the period 1981-1985 a total of four units, two in Almaraz and two in Asco entered in operation. These three loop s Westinghouse units use model D-3 preheater Steam Generators. The poor design and manufacture of the Steam Generators of these units have caused a large number of problems: mechanical (Preheater and AVB's vibration), denting, and primary and secondary stress corrosion cracking. As a ...
1991-09-16
Energy Technology Data Exchange (ETDEWEB)
Triphenylmethylphosphonium (TPMP+) partitions into the mitochondrial and cytosolic compartments in the rat white adipocyte in a potential-dependent fashion. The relationship between (/sup 3/H)TPMP+ distribution, intracellular cAMP generation and lipolysis in response to hormones and cAMP-mimetic compounds was examined. Half-maximal (/sup 3/H)TPMP+ efflux and glycerol release were produced by 15 and 9 nM adrenocorticotropin, 170 and 110 nM 1-epinephrine, 70 and 27 microM isobutylmethylxanthine and 800 and 750 microM dibutyryl cAMP, respectively. Hormone-stimulated cAMP generation was also correlated with (/sup 3/H)TPMP+ efflux and lipolysis in terms of concentration dependency. In kinetic experiments, glycerol release and (/sup 3/H)TPMP+ efflux in response to adrenocorticotropin or cholera toxin proceeded over a similar time course, whereas an earlier rise in cAMP generation was detected. The depolarizing effect of lipolytic compounds was localized to the mitochondrial compartment. When ...
1982-01-01
The thematic plant life assessment network (PLAN)
Energy Technology Data Exchange (ETDEWEB)
The Plant Life Assessment Network (PLAN) is a Brite Euram Type II Thematic Network, initiated by the European Commission to facilitate structured co-operation between all cost shared action projects already funded by the Commission which fall under this common technical theme. The projects involved address a multiplicity of problems associated with plant life assessment and are drawn from Brite-Euram, Standards, Measurement and Testing, Nuclear Fission Safety and Esprit EC programmes. The main aim of the Network is to initiate, maintain and monitor a fruitful co-operation process between completed, ongoing and future EC R and D projects, thereby promoting improved cross fertilization and enhanced industrial exploitation of R and D results. As the project is in its infancy, this presentation covers the background to the initiative in some detail. In particular two key aspects are highlighted, namely, the requirement of the EC to launch such a network in the area of plant life assessment ...
1998-12-31
The risk of ano-genital malignancies in dialysis and transplant patients.
The incidence of anogenital malignancies is greatly increased in patients who have received a renal transplant, but this has not been well studied in patients receiving maintenance dialysis. Our aim was to assess the incidence of these malignancies in patients on dialysis and compare these to transplanted patients. The age standardized incidence ratio (SIR) for anogenital malignancies was calculated by comparing the observed number of malignancies to the expected number. The expected number was calculated by multiplying the age specific incidence rates for each malignancy by the person years at risk in 5-year age cohorts. Of 15,820 patients in the Australia and New Zealand data base, 8,215 had received a renal transplant. A total of 39,750 person years at risk were contributed by patients who had received a renal transplant, while 29,276 person years at risk were contributed by dialysis patients who had not received a renal transplant. For dialysis patients, vulval ...
1994-02-01
The preliminary success of ALARA implementation in Daya Bay NPP
International Nuclear Information System (INIS)
Based on the practical condition of the plant and in reference to advanced management experiences worldwide, Daya Bay Nuclear Power Plant has established its own peculiar management system for radiation protection management and ALARA implementation. The characteristics of the system are: radiation protection training to all workers, active involvement of all managers and staffs, and whole process safety control to maintenance activities. The management philosophy of 'workers are responsible for their own radiation safety' is adopted in the plant. A strict, formalized and systematic whole staff radiation protection training, evaluation, authorization and periodically refreshing mechanism had been established and executed in the plant. In the organizational point of view, the responsibilities of line managers were specified in plant procedures, ALARA coordination organization on plant level and for specific activities were established. Meanwhile, the plant ...
2000-05-01
Energy Technology Data Exchange (ETDEWEB)
The primary coolant oxidises the surfaces of construction materials in nuclear power plants. The properties of the oxide films influence significantly the extent of incorporation of actuated corrosion products into the primary circuit surfaces, which may cause additional occupational doses for the maintenance personnel. The physical and chemical properties of the oxide films play also an important role in different forms of corrosion observed in power plants. This report gives a short overview of the factors influencing activity build-up and corrosion phenomena in nuclear power plants. Furthermore, the most recent modifications in the water chemistry to decrease these risks are discussed. A special focus is put on zinc water chemistry, and a preliminary discussion on the mechanism via which zinc influences activity build-up is presented. Even though the exact mechanisms by which zinc acts are not yet known, it is assumed that Zn may block the diffusion paths within ...
1999-03-01
Tests with cleaned and uncleaned gas on a pilot plant. Final report
Energy Technology Data Exchange (ETDEWEB)
The possibilities for heat recovery in a cast iron melting furnace were studied. A cupola furnace which produces 40 tonnes steel per hour, produces 25,000 Nm/sup 3//h of flue gases which contain 16-22% CO. Taking into account the heat losses at the chimney where fumes are cooled to 200/sup 0/C the recoverable heat is about 12.4-10/sup 6/ kcal/h which mainly consists of combustion heat in CO. This study showed that the heat can be used for the production of electricity, which will be used in the plant. Recovery of 87 kWh of electricity per tonne of steel produced is possible. A steam turbine driven generator of 3.5 MW will be required. The combustion of the low calorific gas (approximately 400 kcal/Nm/sup 3/) has been studied and gave positive results: wet CO gas can be burnt without addition of methane and preheating of air is not required. The pilot plant consisting of a thermic system (combustion chamber and equipment to produce and condense steam without turbine and generator) was ...
1986-01-01
Synopsis of some preliminary computational studies related to unsaturated zone transport at Area G
Energy Technology Data Exchange (ETDEWEB)
Computational transport models are described with applications in three problem areas related to unsaturated zone moisture movement beneath Area G. These studies may be used to support the ongoing maintenance of the site Performance Assessment. The three areas include: a 1-D transient analysis with average tuff hydraulic properties in the near surface region with computed results compared to field data; the influence on near surface transient moisture percolation due to realistic distributions in hydraulic properties derived statistically from the observed variance in the field data; and the west to east moisture flow in a 2-D steady geometry approximation of the Pajarito Plateau. Results indicate that a simple transient model for transport of moisture volume fraction fits field data well compared to a moisture pulse observed in the active disposal unit, pit 37. Using realistic infiltration boundary conditions for summer showers and for spring snow melt conditions, ...
1998-03-01
Energy Technology Data Exchange (ETDEWEB)
The research project's objective is to create a decision help for owners of residential buildings for several families regarding the renewal of decentralized heating and warm water preparation systems in the flats. The focus lies on a comparison of the costs of typical systems on the basis of a full cost calculation. This is done by taking into consideration the intentions of residential building companies like the reduction of additional costs to be paid by the tenants (both for social reasons and to make the flats easier to rent), low investment costs, low maintenance costs, energy saving, tenants' claims for comfort and acceptance by the tenants, economical reasons, especially regarding flats fully amortized (activation in the balance sheet). In addition to the quantitative comparison, the advantages and disadvantages of the different systems were also compared to one another from the qualitative point of view. [German] Ziel des ...
2004-04-01
Software for production scheduling in hydro systems
Energy Technology Data Exchange (ETDEWEB)
The report presents an integrated software system developed at the Norwegian Electric Power Research Institute (EFI), for production scheduling, maintenance handling, network security analysis, inflow forecasting, and load forecasting. The integrated software is being developed with focus on hydro-dominated power supply systems. In specific terms it is expected that application of the software will improve the operational decisions, and make the planning process more effective. The optimal scheduling of hydro resources poses severe computational problems in system operations planning. This necessitates problem decomposition. In the EFI approach, planning is split into three main levels: long-term, mid-term and short-term planning. The long-term planning aims at evaluating the seasonal and pluriannual handling of regional storages in view of firm power supply obligations, inflow statistics, main hydraulic and electric transit limitations, and the available options ...
1991-02-01
Smart meter status report from Toronto
Energy Technology Data Exchange (ETDEWEB)
An update of Toronto Hydro's smart metering program was presented. Electricity demand is expected to keep increasing, and there is presently insufficient generation to match supply needs in Ontario. The smart metering program was introduced to aid in the Ontario government's energy conservation strategy, as well as to address peak supply problems that have led to power outages. It is expected that the smart metering program will reduce provincial peak supply by 5 per cent, as the meters support both time-of-use rates and critical peak pricing. Over 800,000 smart meters will be supplied to customers by 2007, and all 4.3 million homes in Toronto will have a smart meter by 2010. In order to meet targets for 2010, the utility will continue to install more 15,000 meters each month for the next 4 years. While the Ontario government has planned and coordinated the rollout and developed smart metering specifications and standards, Toronto Hydro is responsible for the ...
2006-07-01
Risk-based inspection in ASME Section XI
International Nuclear Information System (INIS)
By 1970 the first edition of the ASME Code Section XI, Inservice Inspection of Nuclear Reactor Coolant Systems was published. From its inception, the Section XI inservice inspection scope was based on a fundamental risk-based selection process. In other words the inservice inspection scope included components where the consequences of a pressure boundary failure were high. Once the consequence significant system boundaries were established, inspections would then be performed at locations believed to be most susceptible service induced failure. Current Section XI requirements require that inspection locations be selected on the basis of peak stress and fatigue usage values contained in the Design Reports. These original stress calculations were designed to qualify a design and assure that the plant would provide reliable service throughout its design life. For the most part, the fatigue usage values in these reports do not provide an accurate measure of service life. As service history ...
1996-07-21
Reliability of indices of neuromuscular leg performance in end-stage renal failure.
The purpose of this study was to examine the day-to-day reproducibility and single measurement reliability of peak force, time to half peak force and rate of force development indices of knee extension neuromuscular performance in patients with end-stage renal failure. Eleven self-selected patients (6 men, 5 women) receiving maintenance dialysis (dialysis history 67 +/- 42.8 month) completed 3 inter-day assessment sessions. Each comprised a standardized warm-up and 3 intermittent static maximal voluntary actions of the knee extensors of the preferred limb (45 degrees knee flexion angle [0 degrees = full knee extension]) using a specially-constructed dynamometer. Repeated measures ANOVA of coefficient of variation scores revealed significant differences between indices in their reproducibility across day-to-day trials. Post-hoc comparisons of group mean scores suggested that peak force (6.6 +/- 3.0%) offers significantly greater measurement reproducibility than time ...
2002-11-01
Passive, integrated measurement of radon using 5A synthetic zeolite and blue silica gel
Energy Technology Data Exchange (ETDEWEB)
Synthetic zeolite of 0.5 nm pore size (5A) and blue silica gel were tested to determine their capability to be used as radon collectors. Tests conducted in a radon chamber under controlled conditions of temperature and relative humidity indicate that simple, inexpensive and maintenance-free passive devices containing about 250 g of synthetic zeolite or about 270 g of blue silica gel in open face metal canisters that can measure radon conveniently and adequately, the latter though being suitable only for dry-medium dry atmosphere with quite high radon concentrations. Both materials can be recycled for reuse, in a way similar to the recycle and reuse of active carbon. The amount of radon adsorbed in such collectors is determined by counting the gamma rays from the radon decay products. The lower limit of detection (LLD) is estimated to {approx}45 Bqm{sup -3} for the synthetic zeolite and to {approx}350 Bqm{sup -3} for the blue silica gel, for an exposure of 48 h at a ...
2010-01-15
Energy Technology Data Exchange (ETDEWEB)
Statoil is operating an increasing number of offshore and onshore pipelines in the North Sea area and elsewhere. Cathodic protection is a significant part of the corrosion management for these lines and we have collected a significant amount of experience with respect to design and operation of the systems. This paper deals with our comprehensive program for the onshore cathodic protection systems and the various challenges in different countries with respect to technical matters, such as operating conditions and different terrain. Generally, the systems are based on automatically controlled rectifier systems with a wide range of current drainage and very comprehensive monitoring of potentials and current flowing. The use of coupons, polarisation cells and buried reference cells are essential, as well as the use of intensive measurements along the route. The use of online monitoring of selected test posts and all rectifier units is considered essential for remote areas and in a ...
1999-07-01
Energy Technology Data Exchange (ETDEWEB)
PETROBRAS/TRANSPETRO Pipelines and Terminals has 500 regular employees and 5.064 out sourced workers in its Southeast Division. The out sourced employees work through 125 contracts involving a wide range of activities such as maintenance, operational, pipeline launching , engineering, administrative and auxiliary services. Among these workers, 200 people are subjected to benzene occupational exposure, which might be present in the products we transport in our pipelines. Benzene is recognized as a carcinogen according to ACGIH and Brazilian Ministry of Labour regulation NR- 15. Exposure to benzene in an uncontrolled way, be it chronic or sharp, may affect the worker's health such as: hematological alterations, neoplasys, neurobehavior alterations. Our program PPEOB (acronym in Portuguese for benzene occupational exposure prevention program) involved the work force and fosters health by anticipation, recognition, evaluation and control of the situations that ...
2004-07-01
Energy Technology Data Exchange (ETDEWEB)
PETROBRAS/TRANSPETRO Pipelines and Terminals have 500 regular employees and 5.064 out sourced workers in its Southeast Division. The out sourced employees work under 125 contracts involving a wide range of activities such as maintenance, pipeline operation, pipeline launching, engineering, administrative and auxiliary services. Among these workers, 1.200 peoples are subjected to occupational exposure, which may be present in the industrial process or in the products transported in our pipelines, e.g. industrial noise, sulfidric gas, toluene, xylene and benzene (recognized as a carcinogen according to ACGIH and Brazilian Ministry of Labour). Our PPRA (acronym in Portuguese for Occupational Exposure Prevention Program) involves the workforce and fosters health by anticipation, recognition, evaluation and control of the situations that may result in injuries. Further actions include the procurement of equipment for detection of these agents not only in the air but ...
2005-07-01
Mitigating aging in CANDU plants
Energy Technology Data Exchange (ETDEWEB)
Aging degradation is a phenomenon we all experience throughout life, both on a personal basis and in business. Many industries have been successful in postponing the inevitable impact on their related systems and components through programs to maintain long-term reliability, maintainability and safety. However, this has not always been the case for nuclear power. While all power plants are experiencing the world trend of increasing operating costs with age, few (if any) have been able to fully define the parameters that solve the aging equation, particularly in relation to major components. Inspection and preventive maintenance have not been effective in predicting life-limiting degradation and failure. In CANDU nuclear plants, utilities are taking a comprehensive approach in dealing with the aging problem. Programs have been established to identify the current condition and degradation mechanisms of critical components, the failure of which would impact negatively ...
1995-07-01
Energy Technology Data Exchange (ETDEWEB)
In front of the risks linked with the increase of the greenhouse gas emissions in the atmosphere, the decision makers must take into consideration first, the scientific advice of climatic change experts, and second, the considerable inertia of the climatic system. Thus, any action implemented so far will have an impact all along the 21. century and later whatever the future human activities. The aim of this memento is to sensibilize the decision makers about the possible consequences of their choice in terms of volume of greenhouse gases and of medium- and long-term evolution: 1 - stakes, role of local decision-makers (greenhouse effect and climatic change, France's international commitment, stakes, liabilities of local decision makers, decentralization laws, local plans of fight against greenhouse effect, public information and dialogue); 2 - urbanism and transports (urban displacements, alternatives to individual cars, collective transportation systems, parking, inter-region ...
2003-07-01
Lubricant wear particle analysis by filter patch extraction
Energy Technology Data Exchange (ETDEWEB)
Lubricating Oil Analysis (LOA) has become an important part of a comprehensive Reliability Centered Maintenance (RCM) program. However, knowing the condition of the lubricant alone does not provide a complete description of equipment reliability. Condition monitoring for equipment can be accomplished through Wear Particle Analysis (WPA). This usually involves separating suspended materials and wear products from the lubricant by magnetic (ferrographic) means. This paper will present a simple, low-cost, alternate method of particle acquisition called Filter Patch Extraction (FPE). This method removes solids, regardless of their composition, from the lubricant by vacuum filtration and deposits them onto a filter for microscopic examination similar to that of analytical ferrography. A large filter pore size retains suspended materials and permits rapid filtration of large volumes of lubricant thereby increasing the accuracy of the wear and cleanliness profile that can ...
1996-07-01
Energy Technology Data Exchange (ETDEWEB)
As part of the work scope set in the French law on high level long lived waste R&D passed in 1991, CEA is conducting a research program to establish the scientific basis and assess the feasibility of long term storage as an option for the safe management of nuclear waste for periods as long as centuries. This goal is a significant departure from the current industrial practice where storage facilities are usually built to last only a few decades. From a technical viewpoint such an extension in time seems feasible provided care and maintenance is exercised. Considering such long periods of time, the risk for Society of loosing oversight and control of such a facility is real, which triggers the question of whether and how long term storage safety can be actually achieved. Therefore CEA commissioned a study (1) in which MUTADIS Consultants (2) and CEPN (3) were both involved. The case study looks into several past and actual human enterprises conducted over ...
2003-02-24
Intensive combined modality therapy including low-dose TBI in high-risk Ewing's sarcoma patients
International Nuclear Information System (INIS)
Twenty-four high-risk Ewing's sarcoma patients were treated on an intensive combined modality protocol including low-dose fractionated total body irradiaiton (TBI) and autologous bone marrow infusion (ABMI). Twenty patients (83%) achieved a complete clinical response to the primary and/or metastatic sites following induction therapy. The median disease-free interval was 18 months, and nine patients remain disease-free with a follow-up of 22 to 72 months. Local failure as a manifestation of initial relapse occurred in only three patients (15%), each having synchronous distant failure. Eight patients failed initially with only distant metastases, usually within 1-2 years following a complete clinical response. Two patterns of granulocyte recovery following consolidative therapy (including TBI and ABMI) were recognized. The time to platelet recovery was different for the groups with early and late granulocyte recovery. Patients with late recovery did not tolerate ...
Integrated design environment for human performance and human reliability analysis
Energy Technology Data Exchange (ETDEWEB)
Work over the last few years at the Idaho National Engineering and Environmental Laboratory (INEEL) has included a major focus on applying human performance and human reliability knowledge and methods as an integral element of system design and development. This work has been pursued in programs in a wide variety of technical domains, beginning with nuclear power plant operations. Since the mid-1980`s the laboratory has transferred the methods and tools developed in the nuclear domain to military weapons systems and aircraft, offshore oil and shipping operations, and commercial aviation operations and aircraft design. Through these diverse applications the laboratory has developed an integrated approach and framework for application of human performance analysis, human reliability analysis (HRA), operational data analysis, and simulation studies of human performance to the design and development of complex systems. This approach was recently tested in the NASA Advanced Concepts Program ...
1997-05-01
International Nuclear Information System (INIS)
Norway is a member of Annex 29, 'Ground-Source Heat Pump Systems Overcoming Technical and Market Barriers' (2004-2006), organized under the umbrella of the International Energy Agency (IEA) and the IEA Heat Pump Programme (HPP). The 7 participating countries are Austria (Operating Agent), Canada, Japan, Norway, Spain, Sweden and the USA. The Norwegian participation is financed by ENOVA SF, and SINTEF Energy Research is responsible for planning and carrying out the Norwegian activities. This report provides a status for ground-source heat pump (GSHP) systems in Norway with regard to state-of-the-art technology, installation examples, geological data, costs and market opportunities. A Norwegian Internet home page for ground-source heat pump systems (www.energy.sintef.no/prosjekt/Annex29) is also presented. GSHP systems in Norway are classified as direct systems (groundwater and soil/ground) and indirect closed-loop systems (vertical-rock and horizontal-soil/ground). The vast majority of ...
High angle conveyors for surface mining in the 90s
Energy Technology Data Exchange (ETDEWEB)
High angle conveyor systems in open pit mining offer many advantages over the traditional, truck only, haulage systems, including: (1) superior energy efficiency (2) less dependency on petroleum products (3) less sensitivity to inflation (4) less labour (5) less excavation for the amount of ore recovered, and (6) less ramp construction and maintenance costs. This paper presents the sandwich belt high angle conveyor as the vital link to optimisation of inpit conveying systems. High angle conveyor development to date is discussed, beginning with studies in 1979, to the first large scale prototype in 1983, through the numerous commercial installations. Discussion continues with the high angle conveyor systems to suit the various open pit mining operations and the corresponding characteristics of the system components, particularly the high angle conveyor. The range of high angle conveyor systems from the low capacity (up to 1 814 t/h), low lift (10.7 to 36.6 m), ...
1991-04-01
Geothermal Heat Pump Profitability in Energy Services
Energy Technology Data Exchange (ETDEWEB)
If geothermal heat pumps (GHPs) are to make a significant mark in the market, we believe that it will be through energy service pricing contracts offered by retailcos. The benefits of GHPs are ideally suited to energy service pricing (ESP) contractual arrangements; however, few retailcos are thoroughly familiar with the benefits of GHPs. Many of the same barriers that have prevented GHPs from reaching their full potential in the current market environment remain in place for retailcos. A lack of awareness, concerns over the actual efficiencies of GHPs, perceptions of extremely high first costs, unknown records for maintenance costs, etc. have all contributed to limited adoption of GHP technology. These same factors are of concern to retailcos as they contemplate long term customer contracts. The central focus of this project was the creation of models, using actual GHP operating data and the experience of seasoned professionals, to simulate the financial ...
1997-11-01
GASVOL 18'' gas pipeline - risk based inspection study
Energy Technology Data Exchange (ETDEWEB)
This paper describes a risk based approach and inspection planning as part of the Pipeline Integrity Management (PIM) system for the 95.5 km long 18'' GASVOL gas pipeline in the South eastern region of Brazil transporting circa 5 000 000 m3 dry gas per day. Pipeline systems can be subject to several degradation mechanisms and inspection and monitoring are used to ensure system integrity. Modern pipeline regulations and codes are normally based on a core safety or risk philosophy. The detailed design requirements presented in design codes are practical interpretations established so as to fulfill these core objectives. A given pipeline, designed, constructed and installed according to a pipeline code is therefore the realization of a structure, which, along its whole length, meets the applicable safety objectives of that code. The main objective of Pipeline Integrity Management (PIM) is to control and document the integrity of the pipeline for its whole service life, ...
2003-07-01
Food packaging and radiation sterilization
International Nuclear Information System (INIS)
Radiation sterilization has several merits that it is a positively effective sterilization method, it can be used to sterilize low heat-resistant containers and high gas barrier films, and there is no possibility of residual chemicals being left in the packages. It has been commercially used in 'Bag in a Box' and some food containers. The #gamma# ray and an electron beam are commonly used in radiation sterilization. The #gamma# ray can sterilize large size containers and containers with complex shapes or sealed containers due to its strong transmission capability. However, since the equipment tends to be large and expensive, it is generally used in off production lines. On the other hand, it is possible to install and electron beam system on food production lines since the food can be processed in a short time due to its high beam coefficient and its ease of maintenance, even though an electron beam has limited usage such as sterilizing relatively thin materials ...
1998-12-08
First North American longwall in pitching seams proven feasible. [Colorado
Energy Technology Data Exchange (ETDEWEB)
There are 1.4 Gt (1.5 billion st) of recoverable coal under less than 914 m (3,000 ft) of cover in Colorado in pitching seams. Snowmass Coal Co., in cooperation with the US Department of Energy, introduced the longwall mining method in pitching seams to North America. This venture is a coal mining research program directed toward the profitable production of coal under difficult mining conditions as found in pitching seams of the western US. Snowmass Coal classifies pitching seams into the following categories for longwall on the strike in seams 3 m (10 ft) or less thick: Flat = 0 to 10/sup 0/: Normal continuous mines and shuttle cars work efficiently. Slight = 10/sup 0/ to 22/sup 0/: The maximum pitch that rubber tired equipment will function. Moderate = 22/sup 0/ to 40/sup 0/: The angle of repose of mined coal. Steep = 40/sup 0/ to 60/sup 0/: The limit of safe use of this roof support. Vertical = over 60/sup 0/. The longwall roof support covered here will work in all pitches except ...
1983-12-01
Energy Technology Data Exchange (ETDEWEB)
In 1986, following comprehensive preliminary studies, a 17 MW battery energy storage plant was set up in the insular power supply system of Berlin (West) for the purpose of frequency and output control and provision of immediate reserve capacities. The present paper reports on the initial task, and the dimensioning and construction of this large-scale demonstration as well as the costs entailed in this. It also relates the experiences gained with the operation of the battery energy storage plant in its function as a fast-responding control unit and gives an account of its economic efficiency. Recent studies on the economic efficiency of the plant in conditions as they exist in the present interconnected power supply system are presented. Finally the author reports on the experiences gained with individual plant components, i.e., battery, battery periphery, and power converter and quantifies the cost of plant operation, maintenance, and servicing. (orig./HW) ...
1996-12-31
Experience from Arctic projects : meeting the challenges of Arctic and harsh environment projects
Energy Technology Data Exchange (ETDEWEB)
The main businesses of the Aker Group were outlined. The Aker Group has an operating revenue of 51.7 billion with operational experience in deepwater floaters, subsea infrastructure, onshore oil and gas plants, fixed offshore platforms, petrochemical refining, power generation, pulping, and mining. The company plans and executes capital projects, provides technology solutions and life-cycle operations, service and maintenance. The Aker Group owns 50 per cent of the Aker Kvaener offshore drilling rig located in the North Sea. This presentation outlined the challenges of working in a harsh environment. The area is characterized by a short productive season, low temperatures and limited sunlight. The direct environmental issues include spills and the impact of oil and gas infrastructure. Indirect issues include lowering the entry barriers for other kinds of resource exploitation. Other challenges of field development in Arctic areas include ice conditions, extreme ...
2005-07-01
Dosimetry audit on the accuracy of 192Ir brachytherapy source strength determinations in Sweden
Energy Technology Data Exchange (ETDEWEB)
The absorbed dose delivered to the patient in brachytherapy is directly proportional to the source strength in terms of the reference air-kerma rate (RAKR). Verification of this quantity by the hospitals is widely recognized as an important part of a quality assurance program. An external audit was performed on behalf of the Secondary Standard Dosimetry Laboratory at the Swedish Radiation Protection Authority (SSI). The aim was to investigate how accurately the source-strength in 192Ir brachytherapy is determined at Swedish hospitals. The SSI reference well-type ion chamber and calibrated equipment were used to measure the RAKR of an 192Ir source in each of the 14 Swedish afterloading units. Comparisons with values determined by vendors and hospitals were made. Agreement in values of RAKR as determined by SSI, hospitals and vendors were in all cases within the +-3% uncertainty (at a coverage factor of k=2), typically guaranteed by the vendors. The good agreement reflects the robustness ...
2007-11-15
Corrosion probes for fireside monitoring in coal-fired boilers
Energy Technology Data Exchange (ETDEWEB)
Corrosion probes are being developed and combined with an existing measurement technology to provide a tool for assessing the extent of corrosion of metallic materials on the fireside in coal-fired boilers. The successful development of this technology will provide power plant operators the ability to (1) accurately monitor metal loss in critical regions of the boiler, such as waterwalls, superheaters, and reheaters; and (2) use corrosion rates as process variables. In the former, corrosion data could be used to schedule maintenance periods and in the later, processes can be altered to decrease corrosion rates. The research approach involves laboratory research in simulated environments that will lead to field tests of corrosion probes in coal-fired boilers. Laboratory research has already shown that electrochemically-measured corrosion rates for ash-covered metals are similar to actual mass loss corrosion rates. Electrochemical tests conducted using a potentiostat ...
2005-01-01
International Nuclear Information System (INIS)
White lupin (Lupinus albus L.) is an annual crop that has been used for phytostabilization of acidified multi-contaminated soils. Once the culture cycle is over, after shoot harvesting, a progressive transference of contaminants from roots to soil may take place as decomposition of roots occurs. An incubation experiment with Cu, Zn, Cd, and As-loaded roots of white lupin and soils with different pH values and concentrations of these contaminants from the area affected by a mine spill at Aznalcollar (near Seville, Spain) was performed in order to assess the effect of the decomposition of the roots to the pH and (NH_4)_2SO_4-extractable levels of these pollutants in the soils. Pollutants loaded-roots were mineralized (56 d) at a ratio similar to animal manures (15.8-19.4% of total organic carbon) in soil. The estimated root inputs of contaminants in comparison to their extractable concentrations in soil were high, especially in the control, non-contaminated and neutral contaminated ...
2008-03-01
Contingency interim measure for the public water supply at Barnes, Kansas.
Energy Technology Data Exchange (ETDEWEB)
This document presents a conceptual design for a contingency interim measure (IM) for treatment of the public water supply system at Barnes, Kansas, should this become necessary. The aquifer that serves the public water supply system at Barnes has been affected by trace to low concentrations of carbon tetrachloride and its degradation product, chloroform. Investigations conducted on behalf of the CCC/USDA by Argonne National Laboratory (Argonne 2008a) have demonstrated that groundwater at the Barnes site is contaminated with carbon tetrachloride at concentrations exceeding the Kansas Tier 2 risk-based screening level (RBSL) and the EPA maximum contaminant level (MCL) of 5.0 {micro}g/L for this compound. The Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) formerly operated a grain storage facility in Barnes, approximately 800 ft east-southeast of the public water supply wells. Carbon tetrachloride was used in the treatment of grain. Another potential source ...
2009-07-09
Choice of energy data in environmental assessment of the built environment
Energy Technology Data Exchange (ETDEWEB)
Life cycle oriented methods are increasingly used for environmental assessments (EAs) of the built environment. However, many assumptions are made in such assessments, potentially influencing the results and making the assessment more ambiguous. To increase the reliability of EAs, consequences of the assumptions made have to be better understood. Since energy use in the operation and maintenance phase is an important factor decisive for the overall environmental performance of a building, the purpose of this study is to investigate how the selection of heat and electricity mix affects the assessed environmental performance of buildings. It also aims to suggest how to choose heat and electricity data in EAs of the built environment in general. Applying four different modes of electricity production and two different modes of heat production in a case study of three different buildings with different technical solutions for heat and electricity supply, the study show ...
2003-03-01
Chalon/Saint-Marcel manufacturing plant; L'usine de Chalon/Saint-Marcel
Energy Technology Data Exchange (ETDEWEB)
AREVA is the world leader in the design and construction of nuclear power plants, the manufacture of heavy components, and the supply of nuclear fuel and nuclear services such as maintenance and inspection. The Equipment Division provides the widest range of nuclear components and equipment, manufactured at its two facilities in Jeumont, northern France, and St. Marcel, in Burgundy. The St. Marcel plant, set on 35 ha (87.5 acres) near Chalon-sur-Saone, was established in 1973 in a region with a long history of specialized metalworking and mechanical activities to meet the demand for non-military nuclear requirements in France. The site offers two advantages: - excellent facilities for loading and transporting heavy components on the Saone river, - it's proximity to other group sites. Since its completion in 1975, the Chalon/St. Marcel facility has manufactured all the heavy components for French pressurized water reactors (PWRs) ranging from 900 MW to 1500 ...
2008-07-01
We conducted a retrospective review of the North American Renal Transplant Cooperative Study (NAPRTCS) Registry transplant and dialysis arms to assess anemia and growth patterns in children who returned to dialysis after a failed renal transplant from January 1, 1992 to February 3, 2004. Of the 1807 potential study subjects, 1451 had transplant removal data (TxIn vs. TxOut) available for analysis. Four hundred and twenty-one of 1451 patients (29%) had a transplant nephrectomy at the time of entry into the NAPRTCS Registry Dialysis arm. Anemia rates steadily decreased from 72.2% at 30 days after dialysis initiation to 59.5% at 12 months after dialysis initiation. Factors associated with anemia at 30 days after dialysis initiation included hemodialysis, lack of Epo use, and patients who comprised earlier study era cohorts. At one yr after return to dialysis, earlier study cohort era was the only factor associated with anemia status. Patients did not demonstrate significant improvement in ...
2007-03-01
An evaluation of the performance of integrated bioenergy systems
Energy Technology Data Exchange (ETDEWEB)
A comprehensive study of biomass production conversion and utilisation systems has been carried out to examine complete bio-energy systems from biomass in the forest to electricity delivered to the grid. Models have been derived for all of the key steps in an integrated process which have been compiled into an overall system model. Biomass production from short rotation forestry and from conventional forestry is modelled on an individual operation basis in terms of the performance and cost of each step. This includes planting, maintenance, harvesting, chipping, storage and transport. Biomass conversion includes pretreatment (reception, storage, handling, comminution, screening and drying); atmospheric gasification (generic gasifier, water scrubbing, gas engine); pressure gasification (generic gasifier, hot gas clean-up, gas turbine, HRSG, steam turbine); fast pyrolysis for liquid bio-fuel-oil (pyrolyser, oil storage, dual fuel engine); combustion (fluid bed ...
1995-11-01
Allocation of risks in a competitive electric market
Energy Technology Data Exchange (ETDEWEB)
To many, recent developments in electric markets are perplexing. Competition has appeared, often in the form of new players who do not own and operate generation or transmission facilities. Yet, these players happily enter into contracts obliging them to make or take delivery of power at set prices for months or even years into the future. They seem unconcerned about predicted capacity shortages, fuel price uncertainty or unpredictable plant outages. For the most part, these new players understand these risks quite well. They simply believe in the efficacy of markets. Until recently, price ensured recovery of cost. They foresee a true market where price makes supply equal demand and cost is not a factor in the short term at least. The appearance of such players is an augury of the new industry structure, one in which specialists in taking and managing distinct business risks evolve from within or enter from outside. They take and manage price risk in much the same way that other new ...
1996-03-01
International Nuclear Information System (INIS)
Korea Atomic Energy Research Institute, using the ANS Low Power /Shutdown (LPSD)PRA Standard, evaluated the LPSD PSA model of the KSNP, Younggwang (YGN) Units 5 and 6, and identified the items to be improved. The evaluation results of human reliability analysis (HRA) of the pre-accident human errors in the LPSD PSA model of the KSNP showed that 13 items among 15 items of supporting requirements for those in the ANS PRA Standard were identified as them to be improved. Thus, we newly carried out a HRA for pre-accident human errors in the LPSD PSA model for the KSNP to improve its quality. We considered potential pre-accident human errors for all manual valves and control/instrumentation equipment of the systems modeled in the KSNP LPSD PSA model except reactor protection system/ engineering safety features actuation system. We reviewed 160 manual valves and 56 control/instrumentation equipment. The number of newly identified pre-accident human errors is 101. Among them, the number of ...
2003-04-20
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.
