WorldWideScience
1

SLEEPER FOR CRUSHED-STONE BALLAST  

J-STORE (Japan)

Full Text Available

2007-11-09

2

Proposing radioactivity limits for building materials  

International Nuclear Information System (INIS)

A nation-wide survey of natural radioactivity in building materials was conducted during 1982-1984. Samples including industrial wastes, by-products and common building materials were collected from main building material manufactories in 29 provinces except Taiwan. The results of exposure rates, specific activities and release rate for "2"2"2Rn are presented. The specific activities of common materials are listed in declining order as follows: clay bricks > common concrete and sandstones > limes and ordinary cement. The highest level was found in breeze bricks made of stone coal, phosphogypsum and red mud with high intrinsic radioactivity. Therefore, these raw materials should be strictly controlled in manufacturing building materials. The measurement results also showed that the typical specific activities of common building materials in our country were ...

3

Comparison between two shock wave regimens using frequencies of 60 and 90 impulses per minute for urinary stones  

UK PubMed Central (United Kingdom)

PURPOSE:Two different regimens of SWL delivery for treating urinary stones were compared.METHODS:Patients with urinary stones were randomly divided...Full Text Available

2010-10-01

4

PIXE analysis of chinese chicken-blood stone  

Energy Technology Data Exchange (ETDEWEB)

This paper reports the chemical compositions of chicken-blood stone Ji Xue Shi measured by Proton Induced X-ray Emission (PIXE). The experimental result show that for the red portion of chicken-blood stone, the concentration of Hg is as high as 20 wt%, and the concentration of S can be above 10 wt%. For the non-red portion the main chemical compositions are Al{sub 2}O{sub 3} and SiO{sub 2}. The obtained chemical compositions are close to those of kaolinite for Balin chicken-blood stone, and of pyrophyllite for Changhua chicken-blood stone, respectively. So far many Changhua chicken-blood stones and Balin chicken-blood stones were found in China, the PIXE method can be used to explore the provenance of available chicken-blood stones. (author)

1999-07-01

5

Treatment of large proximal ureteral stones: extra corporeal shock wave lithotripsy versus semi-rigid ureteroscope with lithoclast  

UK PubMed Central (United Kingdom)

PurposeAssessment of safety and efficacy of extracorporeal shockwave lithotripsy versus semi-rigid ureteroscope with lithoclast for treatment of large proximal ureteral stones.Materials...Full Text Available

6

TASK 2.5.4 DEVELOPMENT OF AN ENERGY SAVINGS CALCULATOR  

Energy Technology Data Exchange (ETDEWEB)

California s major energy utilities and the California Energy Commission (CEC) are seeking to allocate capital that yields the greatest return on investment for energy infrastructure that meets any part of the need for reliable supplies of energy. The utilities are keenly interested in knowing the amount of electrical energy savings that would occur if cool roof color materials are adopted in the building market. To meet this need the Oak Ridge National Laboratory and the Lawrence Berkeley National Laboratory (LBNL) have been collaborating on a Public Interest Energy Research (PIER) project to develop an industry-consensus energy-savings calculator. The task was coordinated with an ongoing effort supported by the DOE to develop one calculator to achieve both the DOE and the EPA objectives for deployment of cool roof products. Recent emphasis on domestic building energy use has made the work a top priority by the Department of Energy s (DOE) ...

2010-03-01

7

Citrat og nyresten  

DEFF Research Database (Denmark)

Citrate is an important naturally occurring inhibitor of calcium stone formation in urine. Urinary citrate excretion was examined in 43 consecutive patients with recurrent idiopathic calcium nephrolithiasis and in 50 normal controls by a specific enzymatic technique. Hypocitraturia (<1.6 mmol/24h) was found in 14 (33%) stone formers compared to 6 (12%) normal controls (p = 0.03). Citrate excretion expressed as citrate-creatinine ratio in 24 hour urine samples was significantly lower in the stone formers than in the healthy controls (p = 0.03), and significantly lower in healthy men, compared to healthy females (p = 0.006). There was a great variability in urinary citrate levels in both groups, and a considerable overlap in the urinary citrate excretion between normal subjects and stone formers. Factors other than urinary citrate excretion must therefore be of importance in the pathophysiology of ...

1993-01-01

8

Cholangiocarcinoma associated with recurrent pyogenic cholangitis: sonographic and CT findings  

International Nuclear Information System (INIS)

Cholangiocarcinoma may be associated with recurrent pyogenic cholangitis as a complication of longstanding proliferative cholangitis in the presence of intrahepatic stones. Sonographic and CT findings of six patients with cholangiocarcinoma of the liver associated with recurrent pyogenic cholangitis are presented. The cases were among 128 patients who underwent partial resection of the liver because of recurrent pyogenic cholangitis and its complication. On sonogram the mass was depicted in four patients as an ill-defined heterogenously echogenic mass and in one patient as a bulging contour; in the remaining one case the mass was not detected. There were small or large, shadowing or non shadowing stones within the tumor in five cases. In one case, the stone was in the duct proximal to the tumor. On CT scans of four patients, the tumors were depicted as an ill-defined, irregular low attenuation masses with variable contrast ...

1992-01-01

9

Weathering behaviour and construction suitability of dimension stones from the Drei Gleichen area (Thuringia, Germany)  

British Library Electronic Table of Contents (United Kingdom)

The construction suitability of a dimension stone depends on its weathering properties along with the petrology and the petrophysical properties. The aim of this study was to evaluate the suitability of the dimension stones from the ?Drei Gleichen? area for construction and replacement purposes. In total, six sandstones (Ingersleben, Wachsenburg, Hindfelden, Seeberg, R?hnberg, Gleichenberg; Upper Triassic) as well as two carbonates (Wachsenburg sinter; Quaternary, Wandersleben dolomite; Middle Triassic) were analysed. The results from our laboratory and on-site studies of the dimension stones show that rocks from the same stratigraphic layer, like the sandstones from the upper Triassic, can show major differences in their petrophysical and weathering properties. These differences are attri...

2011-01-01

10

Percutaneous nephrolithotomy for staghorn kidney stones in elderly patients  

British Library Electronic Table of Contents (United Kingdom)

Purpose We retrospectively analyzed the results of percutaneous nephrolithotomy operations for treatment of staghorn kidney stone disease in elderly patients and compared surgical parameters and outcomes with a control group of young adult patients. Patients and method Between 2002 and 2010, 300 consecutive patients underwent percutaneous nephrolithotomy operation for treatment of staghorn kidney stone disease. Forty-five of the patients were older than 65?years and considered to be in elderly group. Thirty-seven of the patients were between the ages 18 and 36?years and considered to be the control group. Surgical parameters and outcomes were compared between groups. Results There were no significant differences between groups for stone area, operation time, difference in hemoglobin levels...

2011-01-01

11

Laboratory Description of Harbor Idealized Tests. Volume 1 ...  

Science.gov (United States)

... modules 2 and 3, 45 ft from each end) in a ... The toe of the stone revetment was 2 ft out from the ... in parentheses are for the current meters in layout 2. ...

1993-03-01

12

Gallbladder function and dynamics of bile flow in asymptomatic gallstone disease  

UK PubMed Central (United Kingdom)

AIM: To investigate the effects of gallbladder stones on motor functions of the gallbladder and the dynamics of bile flow in asymptomatic gallstone disease.METHODS: Quantitative hepatobiliary...Full Text Available

2009-06-14

13

Final Environmental Baseline Survey Report For The Plum Brook ...  

Science.gov (United States)

9-foot 9-inch blocks of concrete with asphaltic-filled expansion joints. The concrete was placed on 4 to 6 inches of gravel or #4 stone. ...

14

Bladder outlet obstruction in male cystinuria mice  

UK PubMed Central (United Kingdom)

BackgroundCystinuria is the most common inherited cause of urinary tract stones in children. It can lead to obstructive uropathy, which is a major cause of renal...Full Text Available

2010-03-01

15

AN ANNOTATED BIBLIOGRAPHY OF ADULT LITERACY ...  

Science.gov (United States)

... Stone, CR & Grover, CC Practice Readers ... Tolbert, M., Withers, S. & Watkins, HT, Good Workers All State Department of Education, Columbia, South ...

1954-09-30

16

How to build a digital library  

CERN Document Server

How to build a digital library

2010-01-01

17

Variants in Inflammation Genes and the Risk of Biliary Tract Cancers and Stones: A Population-based Study in China  

UK PubMed Central (United Kingdom)

To evaluate the role of chronic inflammation in the development of gallstones and biliary tract cancer, we examined the risk associated with 62 single nucleotide polymorphisms (SNPs), including...Full Text Available

2008-08-01

18

Reproductive factors and risks of biliary tract cancers and stones: a population-based study in Shanghai, China  

UK PubMed Central (United Kingdom)

Background:Parity has been linked to gallbladder cancer and gallstones, but the effects of other reproductive factors are less clear.Methods:We examined...Full Text Available

2010-03-30

19

Problematic renal calculi presenting during pregnancy.  

UK PubMed Central (United Kingdom)

Urinary tract calculi presenting during pregnancy are rare, with less than 0.1% of pregnancies being associated with stones, the vast majority being asymptomatic and a chance finding. We outline six...Full Text Available

1996-03-01

20

Print sec333photoindex (256 pages)  

Science.gov (United States)

Electro-Magnet. Antenna Panels Types Simulated Hail Stone Damage A.Panel ...... X-Band Klystron Electro Magnet. 11. I I. 333-6104 AcBc. 333-6105 Color ...

21

Linear and Nonlinear Effects of Habitat Structure on Composition and Abundance in the Macroinvertebrate Community of a ...  

Science.gov (United States)

... describe the relationship (Peake and Quinn, 1993). The power model was considered best if the R2 from this ... when stone abundance was low (Fig. 2). The power model best described the nonlinear relations...

22

Pathophysiology of incomplete renal tubular acidosis in recurrent renal stone formers: evidence of disturbed calcium, bone and citrate metabolism  

DEFF Research Database (Denmark)

Urinary acidification, bone metabolism and urinary excretion of calcium and citrate were evaluated in 10 recurrent stone formers with incomplete renal tubular acidosis (iRTA), 10 recurrent stone formers with normal urinary acidification (NUA) and 10 normal controls (NC). Patients with iRTA had lower plasma standard bicarbonate after fasting (P <0.01) and lower urinary excretion of titratable acid (P <0.05) and citrate (P <0.01) compared with NUA patients and NC, and higher urinary excretion of ammonia (P <0.05) compared with NC (P <0.05). Hypercalciuria was found in 6 of 10 patients with iRTA compared with 3 of 10 with NUA, and 0 of 10 NC. The citrate/calcium ratio in urine was significantly reduced in iRTA compared with the value in NUA (P <0.01), and in NUA compared with NC (P <0.05). Biochemical markers of bone formation (serum osteocalcin) and bone resorption (urinary hydroxyproline) were significantly increased in iRTA ...

1993-01-01

23

Percutaneous treatment of thrombosed native arteriovenous dialysis fistula insufficiency: efficacy of mechanical thrombectomy with using the stone basket  

Energy Technology Data Exchange (ETDEWEB)

We wanted to evaluate the procedural success after percutaneous treatment of thrombosed native arteriovenous dialysis fistula insufficiency and the efficacy of performing mechanical thrombectomy with using the stone basket. From March 2004 to June 2005, 36 thrombosed native hemodialysis access shunts in the upper limbs (brachiocephalic fistulas: 16 and radiocephalic fistulas: 20) were percutaneously treated in 30 patients. Declotting procedures were performed with using urokinase (100,00-200,000 unit) and manual catheter-directed thrombo-aspiration in all the patients. Angioplasty (6 mm in diameter and 4 cm in length) was performed at the identified area of the stenosis and /or with maceration of the thrombus. In 14 cases with massive thrombosis that was refractory to the above mentioned declotting procedures, mechanical thrombectomy with using a Wittich nitinol stone basket (Cook, Bloomington, IN) was performed. Data regarding the procedural ...

2006-06-15

24

Reliability analysis of the downstream face of a rockfill dam. Introductory work  

Energy Technology Data Exchange (ETDEWEB)

Reliability analysis is now being used to a large extent for several civil engineering structures. Such analysis has not been used for rockfill dams, the most common dams in Norway. Following work on reliability analysis for breakwaters, reliability analysis was then used to investigate the ability of the stone material on the upstream face of a rockfill dam to withstand wind generated waves. An attempt is made to follow up this work by including discharge overtopping on a rockfill dam in a reliability analysis. This report primarily goes through previous work on the required weight of protective stones on the downstream face of the dam for specified discharges over the dam and also deals with the probability formulation of extreme floods. A failure function with partial coefficients is formulated. But for reasons of economy the calibration of the partial coefficients remains for a next phase of the project. 14 refs., 17 figs.

1995-02-01

25

Physicochemical basis for formation of renal stones of calcium phosphate origin: calculation of the degree of saturation of urine with respect to brushite  

UK PubMed Central (United Kingdom)

Brushite (CaHPO4·2H2O) was considered to govern the formation of renal calculus of calcium phosphate origin. The degree of saturation of urine with respect to this phase...Full Text Available

1969-10-01

26

Ignition and combustion features of biofuels  

British Library Electronic Table of Contents (United Kingdom)

This paper presents the results of experimental investigations of the ignition and combustion of plant biofuels (wood particles, date stones) and products of their mechanical and thermal treatment (pellets, charcoal) at temperatures typical of the burning process in nonforced furnaces and fixed-bed and fluidized-bed gas producers. The influence of the furnace heat treatment of a fuel on its inflammation and combustion has been revealed. The results have been compared with the known data on the burning of pellets, brown coals, and anthracites and with the calculation by the classical diffusion-kinetic model.

2011-01-01

29

Environmental Effects and Energy Efficiency in Building Design: A Green Building Approach. Part 3. Design Case Studies.  

Science.gov (United States)

Contents: Introduction; Design Criteria for a Green Building; Comparison of Energy Efficiency Measures; Whole House Energy Efficiency; Built Examples of Energy Efficient Houses; and Product Energy of Building Elements.

1993-01-01

30

Small world when building a particle detector prototype, the devil is in the tiny details  

CERN Multimedia

Small world when building a particle detector prototype, the devil is in the tiny details

2004-01-01

31

Aerial picture of BA4 at SPS (LHC T18 building site).  

CERN Document Server

Aerial picture of BA4 at SPS (LHC T18 building site).

1999-01-01

32

Healthy buildings '88. Volume 2. Planning, physics, and climate technology for healthier buildings (Planning, physique et technologie du climat pour des constructions plus saines)  

Energy Technology Data Exchange (ETDEWEB)

The Conference on Building Design and Architecture organized by Swedish Council for Building Research Contents included articles on building physics, thermal-climate technology, and building location and planning.

1988-06-01

33

Environmental effects and energy efficiency in building design - a green building approach. Pt. 2. Basic data for environmental effects  

Energy Technology Data Exchange (ETDEWEB)

A research report presents the basic data required when designing a building with minimal environmental impacts. Topics covered include the energy consumption of building elements during their lifetime, the environmental implications linked to the extraction and processing of building material and the energy consumed in buildings by the occupants. (UK)

1993-12-31

34

Healthy buildings '88. Volume 1. State-of-the-art reviews (Revue de l'etat de la technique)  

Energy Technology Data Exchange (ETDEWEB)

The Conference on Building Design and Architecture organized by Swedish Council for Building Research Contents included articles on building physics, thermal-climate technology, indoor-air-quality technology, construction materials, quality assurance, and building policy and regulation.

1988-06-01

35

Value creation through relationship closeness  

British Library Electronic Table of Contents (United Kingdom)

Globalization and technological innovation are creating dynamic networks or chains of interconnected players, often known as value delivery networks or supply chains, in which a firm, whether manufacturing or service, holds the key to creating and delivering value in the form of offerings to the customers. This idea of value creation and exchange is the foundation stone of relationship marketing and it is considered successful when closeness is said to have been established in the relationship which subsequently leads toward the achievement of objectives. In order to study and understand the creation of value through relationship closeness in a value delivery network particularly at the backward end, a literature review is conducted. A framework is further developed with the help of Interp...

2010-01-01

36

Evidence-Based Drainage of Infected Hydronephrosis Secondary to Ureteric Calculi  

British Library Electronic Table of Contents (United Kingdom)

Abstract Introduction: The obstructed, infected kidney is a urological emergency. It has been accepted that the management of infected hydronephrosis secondary to ureteric stones is through prompt decompression of the collecting system. However, the optimal method of decompression has yet to be established. Materials and Methods: A PubMed and Medline search was performed of all English-language articles from 1960 using key words ?sepsis,?? ?urosepsis,?? ?obstruction,?? ?obstructive pyelonephritis,?? ?pyonephrosis,?? ?infection and hydronephrosis?? ?decompression,?? ?stent,?? ?nephrostomy,?? and ?management.?? The Cochrane database and National Institute for Clinical Effectiveness guidelines were searched using the terms ?sepsis,?? ?urosepsis,?? ?stent,?? ?nephrostomy,?? or ?obstruction.?? ...

2010-01-01

37

Dextranomer/hyaluronic acid copolymer (Deflux) implants mimicking distal ureteral calculi on CT  

Energy Technology Data Exchange (ETDEWEB)

Periureteral or subtrigonal injection of dextranomer/hyaluronic acid (Dx/HA) copolymer (Deflux, Q-Med, Uppsala, Sweden) is an increasingly common endoscopic treatment for vesicoureteral reflux. We report a confusing radiographic finding of bilateral calcified Dx/HA injections initially thought to represent bilateral distal ureteral stones in a boy who presented with intermittent periumbilical pain. Urologists, radiologists, and emergency room physicians should be aware of the potential for calcification of ureteral implants of Dx/HA, and of the potentially confusing radiographic images that may result. (orig.)

2008-01-15

38

Glass Furnace Combustion and Melting Research Facility.  

Energy Technology Data Exchange (ETDEWEB)

The need for a Combustion and Melting Research Facility focused on the solution of glass manufacturing problems common to all segments of the glass industry was given high priority in the earliest version of the Glass Industry Technology Roadmap (Eisenhauer et al., 1997). Visteon Glass Systems and, later, PPG Industries proposed to meet this requirement, in partnership with the DOE/OIT Glass Program and Sandia National Laboratories, by designing and building a research furnace equipped with state-of-the-art diagnostics in the DOE Combustion Research Facility located at the Sandia site in Livermore, CA. Input on the configuration and objectives of the facility was sought from the entire industry by a variety of routes: (1) through a survey distributed to industry leaders by GMIC, (2) by conducting an open workshop following the OIT Glass Industry Project Review in September 1999, (3) from discussions with numerous glass engineers, scientists, and executives, and (4) ...

2004-08-01

39

Laparoskopisk kolecystektomi  

DEFF Research Database (Denmark)

Forty-one patients with uncomplicated gall stone disease were laparoscopied with the object of cholecystectomy. The procedure was accomplished in 36 patients, but the operation had to be transformed to a conventional open operation in five: Fibrosis made dissection of the gall bladder hazardous in four and bleeding during the procedure made immediate laparotomy necessary in one patient, whose postoperative course was uneventful. The median operating time was 100 minutes, range was 60-250 minutes. The only operative complication was bleeding from a trocar puncture hole on the first postoperative day which stopped spontaneously in one patient. Eighteen were sent home on the first postoperative day and 12 patients on the second day. Peroperative cholangiography was performed employing the Olsen-Reddick cholangiography forceps. We have designed a special catheter, which greatly facilitates the procedure. The procedure was accomplished in 27 of 32 planned cases. Two ...

1993-01-01

40

Drinking water composition and incidence of urinary calculus: introducing a new index.  

Science.gov (United States)

INTRODUCTION. We searched for a pathophysiologically based feature of major water electrolytes, which may define water quality better than the water hardness, respecting urinary calculus formation. MATERIALS AND METHODS. Utilizing a multistage stratified sampling, 2310 patients were diagnosed in the imaging centers of the provincial capitals in Iran between 2007 and 2008. These were composed of 1755 patients who were settled residents of 24 provincial capitals. Data on the regional drinking water composition, obtained from an accredited registry, and their relationships with the region's incidence of urinary calculi were evaluated by metaregression models. The stone risk index (defined as the ratio of calcium to magnesium-bicarbonate product in drinking water) was used to assess the risk of calculus formation. RESULTS. No correlation was found between the urinary calculus incidence and the amount of calcium, bicarbonate, or the total hardness of the drinking water. ...

2011-01-01

41

The concentration of natural radioactive materials in building materials  

International Nuclear Information System (INIS)

A survey is given on the results in hand on the natural radioactivity of building materials. It is shown that only a small percentage of building materials has an increased content of radioactive materials. The results are compared with approximate values given in a Russian publication. (orig./AK).

1974-09-23

42

Environmental effects and energy efficiency in building design: A green building approach. Part 1, energy efficiency techniques. Research report  

Energy Technology Data Exchange (ETDEWEB)

;Contents: Energy Use; Building Fabric Performance; Ventilation and Infiltration; Passive Solar Design; Heating Systems and Controls; Hot and Cold Water Provision; and Lighting and Electrical Appliances.

1993-01-01

43

Environmental Effects and Energy Efficiency in Building Design: A Green Building Approach. Part 2. Basic Data for Environmental Effects.  

Science.gov (United States)

The development of comfort in buildings throughout the centuries was influenced by the demand for progress, wealth and innovation in various respects. At present, it seems that progress may only be possible by taking into account the environment and creat...

1993-01-01

44

Environmental Effects and Energy Efficiency in Building Design: A Green Building Approach. Part 1, Energy Efficiency Techniques.  

Science.gov (United States)

Contents: Energy Use; Building Fabric Performance; Ventilation and Infiltration; Passive Solar Design; Heating Systems and Controls; Hot and Cold Water Provision; and Lighting and Electrical Appliances.

1993-01-01

45

Solar cells in architecture; Solceller i arkitekturen  

Energy Technology Data Exchange (ETDEWEB)

This book contains the results of an architectural evaluation of building examples with integrated photovoltaic. Danish Building and Urban Research and Danish Technological Institute conducted the work within the framework of Solar Energy Centre Denmark. Seven examples are selected to inspire Danish architects and building owners to use PV in the building environment. The examples come from Denmark and countries (the Netherlands and Germany) with similar building traditions, climate and solar conditions. All the examples demonstrate architectural concepts that integrate photovoltaic as a natural part of the building envelope. (BA)

2002-07-01

46

Today in History: December 17  

Science.gov (United States)

as manufacturing plants and laboratories, including the Chemical Laboratory at the House of David in Benton Harbor, Michigan. Built in America: Historic Building Buildings Survey/...

2010-12-17

47

Photovoltaics for Buildings: Key Issues in Pursuit of Market Readiness  

Energy Technology Data Exchange (ETDEWEB)

The photovoltaic (PV) industry is rapidly beginning to recognize the market potential of the buildings sector. New PV-for-buildings products have recently become commercially available, and numerous products that are under development will be introduced within the next 5 years. To ensure that these new products will be adopted and used in common building practices, the PV industry should recognize and address important buildings industry issues. These issues include building codes and standards, after-market servicing, education, and warranties and insurance policies. Photovoltaic systems are also still very expensive. The simplest method for increasing their value for a building is to decrease the building's electrical loads through energy efficiency and conservation. Meeting these goals can only be accomplished through ...

1998-10-31

48

A study of the importance of occupancy to building cooling load in prediction by intelligent approach  

International Nuclear Information System (INIS)

Research highlights: #-># The building occupancy affecting the cooling load prediction is studied. #-># PENN model is adopted in this study for predicting the building cooling load. #-># Statistical approach is adopted to result a less prejudice prediction performance. #-># Results show that occupancy data can significantly improve the prediction. -- Abstract: Building cooling load prediction is one of the key factors in the success of energy-saving measures. Many computational models available in the industry today have been developed from either forward or inverse modeling approaches. However, most of these models require extensive computer resources and involve lengthy computation. This paper discusses the use of data-driven intelligent approaches, a probabilistic entropy-based neural (PENN) model to predict the cooling load of a building. Although it is common knowledge that the presence ...

2011-07-01

53

Environmental effects and energy efficiency in building design - a green building approach. Pt. 3. Design case studies  

Energy Technology Data Exchange (ETDEWEB)

This is the third of a series of research reports which builds on the previous contents which dealt with energy efficiency techniques and minimizing the environmental effects of building materials. It presents some specifications for house types and gives built examples of energy efficient homes in Europe. (UK)

1993-12-31

54

Environmental effects and energy efficiency in building design - a green building approach. Pt. 1. Energy efficiency techniques  

Energy Technology Data Exchange (ETDEWEB)

A research report describes the energy efficiency techniques to be employed in designing a building which is ``green``. Topics covered include building fabric performance, ventilation and infiltration, passive solar design, heating systems and controls, hot and cold water provision, lighting and electrical appliances. (UK)

1993-12-31

63

Environmental effects and energy efficiency in building design: A green building approach. Part 2. Basic data for environmental effects. Research report  

Energy Technology Data Exchange (ETDEWEB)

The development of comfort in buildings throughout the centuries was influenced by the demand for progress, wealth and innovation in various respects. At present, it seems that progress may only be possible by taking into account the environment and creating methods of reducing further damage to the environment. The innovative feature of future progress my be reducing the impact on the environment from human and building activities by using appropriate technology. As it is impossible to build without any impact on the environment and this is likely to be so in the future, the objective is and will be to find solutions for buildings which are more compatible with the environment. The objective is to demonstrate that it is viable to design buildings with minimized impact on the environment, while still maintaining appropriate comfort levels.

1993-01-01

64

Indoor radon pollution: Control and mitigation. June 1978-December 1989 (Citations from the NTIS data base). Report for June 1978-December 1989  

International Nuclear Information System (INIS)

This bibliography contains citations concerning the control and mitigation of radon pollution in homes and commercial buildings. Citations cover radon transport studies in buildings and soils, remedial action proposals on contaminated buildings, soil venting, building ventilation, sealants, filtration systems, water degassing, reduction of radon sources in building materials, and evaluation of existing radon mitigation programs including their cost effectiveness. Analysis and detection of radon and radon toxicity are covered in separate published bibliographies. (Contains 129 citations fully indexed and including a title list.).

65

Final report [Homes Tours and Green Building Program Development  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy Office of Building Technology, State and Community Programs sponsored EcoTecture Solutions, Inc. (dba Sustainable Living Alliance {trademark}) in producing two home tours showcasing energy- and resource-efficient buildings in Austin, Texas, held on October 16, 1999, and Albuquerque, New Mexico, held on May 20, 2000. Lists are given of the notable building technologies, passive solar design features, and energy- and water-efficient technologies and design employed in the houses. There were over 1200 visitors to the 22 residential and 3 commercial buildings included in the tour.

2000-06-28

66

Examination of the natural radioactivity of building materials  

International Nuclear Information System (INIS)

Most important radionuclides naturally appearing in minerals used to form building materials are described. The frequently met ranges of concentrations of these radionuclides in the building materials composed from natural products as well as from power-plant wastes and metallurgic plant wastes are discussed and propositions concerning the limitation of presence of radioactive nuclides in the building materials are given, with special concern paid to materials for dwelling and public utility buildings. The elaborated technique of measuring potassium 40, radium 226 and thorium 228 concentrations is presented. Data on the organization of controlling-and-measuring laboratories in this field are given. (author).

1982-01-01

67

Collaboration work for nuclear power building using 3D CAD information  

Energy Technology Data Exchange (ETDEWEB)

In the construction work for the Unit No.5 Turbine Building at Hamaoka Nuclear Power Station, the collaboration work for the planning and the coordination of the building construction and the machinery installation was carried out utilizing three-dimensional computer aided design (3D CAD) information. It was the first time in Japan for a building constructor and a plant manufacturer to work together, exchanging 3D CAD data of the whole building and adjusting the construction schedule. It was made possible to confirm the correspondence concerning the planning of both companies from the primary stage of the project by the total process simulation and to adjust on-going work precisely by the partial process simulation.

2006-02-15

68

Collaboration work for nuclear power building using 3D CAD information  

International Nuclear Information System (INIS)

In the construction work for the Unit No.5 Turbine Building at Hamaoka Nuclear Power Station, the collaboration work for the planning and the coordination of the building construction and the machinery installation was carried out utilizing three-dimensional computer aided design (3D CAD) information. It was the first time in Japan for a building constructor and a plant manufacturer to work together, exchanging 3D CAD data of the whole building and adjusting the construction schedule. It was made possible to confirm the correspondence concerning the planning of both companies from the primary stage of the project by the total process simulation and to adjust on-going work precisely by the partial process simulation.

2006-02-01

69

An assessment of the building sector efficiency resource for the Town of Handlova  

Energy Technology Data Exchange (ETDEWEB)

Purpose of this assessment for this town in the Slovak Republic is to develop information on the building sector energy efficiency and improvement potential for use by town management to support decisions on providing energy services to Handlova citizens. Objectives were to characterize baseline space and water heat energy use and efficiency improvement potential in the residential and nonresidential building sectors. Intention was to identify major areas of efficiency improvement potential and cost-effectiveness. Four levels of energy and fuel prices were used. A significant efficiency resource exists in the space and water heating end uses in these building sectors; it amounts to 42% of the total building sector space and water heat energy consumption.

1995-10-01

70

Scour protection for wind turbine foundations on highly erodible sea bottom  

Energy Technology Data Exchange (ETDEWEB)

Scour around offshore structures is well known. It is caused by the strong eddy formation at the base of the structures protruding from the sea bottom. The strong vortices result in an amplified effective shear stress working on the sea bottom surface adjacent to the structure. When the surrounding sea bottom is lowered the scour protection will end up being a cap on a small hill and when the slopes are getting too steep the scour protection will roll or slide down the sides. It will loose its cohesion and therefore its integrity. This will take place irrespective of the type of scour protection material and the type of scour protection. This report describes scour protections, which can deal with this particular problem. Such a scour protection must be able to sustain the following loads: Be able to follow the lowering of the seabed on its way down; Be resistant to edge scour (scour around the perimeter of the scour protection). The installation of scour protection is not ...

2002-12-01

71

The strong associations between organism characteristics and network architecture  

CERN Document Server

Understanding the dependence and interplay between architecture and function in biological networks has great relevance to disease progression, biological fabrication and biological systems in general. Recent research in complex systems and networks, presents methods to properly mine the architectural interdependence in networks. Guided by such work, we propose methods to associate organism characteristics with network topology by analyzing a large number of architectural patterns. We adopt an automated approach using 11 topological metrics from complex networks to characterize a collection of various kinds of biological networks. Principal component analysis and clustering allow us to extract the indispensable, independent and informative metrics. Using hierarchical linear modeling, we observe that organism characteristics associate with these metrics, surprisingly well. This work can serve as a stepping stone to cataloging biologically relevant topological ...

2009-01-01

72

The evolution of human culture during the later Pleistocene: Using fauna to test models on the emergence and nature of "modern" human behavior  

British Library Electronic Table of Contents (United Kingdom)

It has often been argued that the success and spread of modern humans 50,000years ago was due to a series of key behavioral shifts that conferred particular adaptive advantages. And yet, particularly during the African Middle Stone Age (MSA), some of these "modern" behaviors see only patchy expression across time and space. Recent models have proposed a link between the emergence of modern behaviors and environmental degradation and/or demographic stress. Under these models, modern behaviors represent a form of social/economic intensification in response to stress; if this were the case, signs of subsistence intensification should be more common during periods in which these behaviors are manifested than when they are not. In order to test these models, I analyzed faunal remains from Sibud...

2011-01-01

73

Morphology of modified starches prepared by different methods  

British Library Electronic Table of Contents (United Kingdom)

Morphologies of modified starches prepared using different methods were examined by scanning electron microscopy (SEM). These SEM micrographs provide the following results. To begin with, starch granules underwent a series of changes which resulted in the morphology of modified starch quite different from the native starch with different the methods during the process of modification. For example, hollows emerge on the granules of maltodextrin with low value of dextrose equivalent (DE) prepared by means of spray-drying, but they fell to pieces with the increasing value of DE. The granules of pregelatinized starches manufactured with extrusion technology also showed irregular stone shapes and holes within them while those produced by means of drum-drying presented irregular laminar structur...

2010-01-01

74

Evidence for a 4700-2100 BC palaeoearthquake recorded in a fluvial-archaeological sequence of the Segura River, SE Spain  

British Library Electronic Table of Contents (United Kingdom)

The archaeological excavation of a rock shelter (Abrigo del Pozo) in one of the slopes of the Segura River (SE Spain) has revealed a exceptionally preserved sedimentary record spanning from the Paleolithic to the present-day, which includes an anomalous layer of stones (RFB) fallen from the roof. The sedimentary analysis of the stratigraphic sequence exhumed by the excavation indicates that human occupation of the rock shelter was controlled by fluvial environmental evolution. However, the RFB level resulted in a disturbance of human occupation and normal fluvial sedimentation. From the sedimentary and archaeological pieces of evidence, the RFB level has been interpreted as related to a palaeoearthquake responsible for the collapse of the roof and walls of the rock shelter. The palaeoearth...

2011-01-01

75

Effect of different formulations on tebuconazole residues in stone fruits  

British Library Electronic Table of Contents (United Kingdom)

BACKGROUND: The correlation between pesticide residue levels and formulation of an active substance is often not considered, even if it is reasonable to expect some differences arising from behaviour during dilution and spraying, from adhesion to plant and from degradation. An experimental study to investigate the magnitude of tebuconazole residues as a function of different tebuconazole formulated products was carried out in Italy. The fungicide was applied as wettable powder (WP) and water-dispersible granule (WG) formulations to peach, plum, apricot and nectarine orchards, on four different sites. The fruit samples gained from the field trials were quantitatively analysed by gas chromatography with a nitrogen phosphorus detector (GC/NPD) for tebuconazole residues. RESULTS: Tebuconazole ...

2009-01-01

76

Comparison of the Marginal Fit of Pressable Ceramic to Metal Ceramic Restorations  

British Library Electronic Table of Contents (United Kingdom)

Abstract Purpose: The aim of this in vitro study was to compare the marginal adaptation of a pressed ceramic material, when used with and without a metal substructure, to a traditional feldspathic porcelain-fused-to-metal restoration with a porcelain butt margin. Materials and Methods: A maxillary central incisor typodont tooth was prepared with a 1.5 mm 360degree shoulder with rounded internal line angle, and 30 polyether impressions were made. Dies were poured in type IV dental stone, and 30 restorations were fabricated: 10 metal ceramic restorations (MCR) with porcelain butt joints, 10 pressed to metal restorations (PTM), and 10 all-ceramic restorations (PCR). All restorations were evaluated on their respective dies at 45x magnification using an Olympus SZX-12, measurements of the margi...

2009-01-01

77

Class 1E digital systems studies  

International Nuclear Information System (INIS)

This document is furnished as part of the effort to develop NRC Class 1E Digital Computer Systems Guidelines which is Task 8 of USAF Rome Laboratories Contract F30602-89-D-0100. The report addresses four major topics, namely, computer programming languages, software design and development, software testing and fault tolerance and fault avoidance. The topics are intended as stepping stones leading to a Draft Regulatory Guide document. As part of this task a small scale survey of software fault avoidance and fault tolerance practices was conducted among vendors of nuclear safety related systems and among agencies that develop software for other applications demanding very high reliability. The findings of the present report are in part based on the survey and in part on review of software literature relating to nuclear and other critical installations, as well as on the authors' experience in these areas.

78

Analysis of the changes of vegetation coverage of western Beijing mountainous areas using remote sensing and GIS  

British Library Electronic Table of Contents (United Kingdom)

Mentougou District acts as a crucial component in the ecological buffer in western Beijing mountainous areas, Beijing, China. Using two Landsat MSS/TM images acquired on July 14, 1979 and July 23, 2005, the vegetation coverage of Mentougou District was calculated based on normalized difference vegetation index and spectral mixture analysis (NDVI-SMA) model. Its temporal and spatial changes were analyzed according to digital elevation model (DEM) image, social and economic data. The results showed that the vegetation coverage decreased from 76.4% in 1979 to 72.7% in 2005. Vegetation degradation was probably the result of human disturbance, such as outspreading of resident areas, and coal and stone mining activities, while vegetation restoration might be contributed by the combined effects o...

2009-01-01

79

An historical view of the pineal gland and mental disorders  

British Library Electronic Table of Contents (United Kingdom)

Since Classical Antiquity numerous authors have linked the origin of some mental disorders to physical and functional changes in the pineal gland because of its attributed role in humans as the connection between the material and the spiritual world. The pineal organ was seen as a valve-like structure that regulated the flow of animal spirits through the ventricular system, a hypothesis that took on more vigour during the Middle Ages and the Renaissance. The framework for this theory was ''the three cells of the brain'', in which the pineal gland was even called the ''appendix of thought''. The pineal gland could also be associated with the boom, during this period, of certain legends about the ''stone of folly''. But the most relevant psychopathological role of this organ arrived with Des...

2011-01-01

80

"On the Road" - Reflections on the Security of Vehicular Communication Systems  

CERN Document Server

Vehicular communication (VC) systems have recently drawn the attention of industry, authorities, and academia. A consensus on the need to secure VC systems and protect the privacy of their users led to concerted efforts to design security architectures. Interestingly, the results different project contributed thus far bear extensive similarities in terms of objectives and mechanisms. As a result, this appears to be an auspicious time for setting the corner-stone of trustworthy VC systems. Nonetheless, there is a considerable distance to cover till their deployment. This paper ponders on the road ahead. First, it presents a distillation of the state of the art, covering the perceived threat model, security requirements, and basic secure VC system components. Then, it dissects predominant assumptions and design choices and considers alternatives. Under the prism of what is necessary to render secure VC systems practical, and given possible non-technical influences, ...

2009-01-01

81

Daylighting monitoring protocols and procedures for buildings. A report of Task 21/Annex 29. Daylight in buildings  

Energy Technology Data Exchange (ETDEWEB)

This official IEA report is a deliverable of IEA SHC Task 21/IEA BCS Annex 29: Daylight in Buildings. The Task focuses on daylighting systems and strategies which can be applied in new and existing buildings with a high potential electricity saving potential such as offices, schools, commercial, and institutional buildings. The daylighting performance of these strategies and systems is tested in laboratory facilities, through modeling, and in real case study buildings. This paper provides methods and procedures to evaluate the daylighting performance of real buildings. Annex 29 case studies located in Europe, North America, and Australia. It is a deliverable of Subtask D research projects. The main objective of Subtask D, as stated in the Implementing Agreement of Task 21/Annex 29, is `to demonstrate the viability of daylighting buildings in various world ...

1997-10-01

82

Healthy buildings and installations. Trends at the Healthy Buildings Conference 2003; Gezonde gebouwen en installaties. Trends op Healthy Buildings 2003  

Energy Technology Data Exchange (ETDEWEB)

At the 7th Healthy Buildings Conference, which was held in Singapore, 7-11 December 2003, more than 500 articles to improve public health and productivity of workers in buildings and the performance of installations. Special attention is paid to indoor air quality and thermal comfort in relation to energy efficiency. [Dutch] Op de laatste Healthy Buildings conferentie, december 2003 in Singapore, werden meer dan 500 artikelen gepresenteerd over het creeren van gezonde, productiviteit verhogende gebouwen en installaties. Deze keer lag de nadruk op binnenluchtkwaliteit en thermisch binnenklimaat, onder andere op het aspect energiezuinigheid. Opvallend was ook de aandacht die de problemen met binnenluchtkwaliteit in ontwikkelingslanden kreeg.

2004-02-01

83

Energy saving in existing buildings. Experiences with 'Therma' buildings. Energieeinsparung im Bestand. Erfahrungen mit den Therma-Bauten  

Energy Technology Data Exchange (ETDEWEB)

A number of buildings dating from the 1950s and 1960s were retrofitted with thermal insulation in order to cut energy consumption. This took place within the building competition 'Therma' nitrated by the Federal Ministry of Regional Planning, Building and Town Planning in 1974. Result at that time were so encouraging that now, 15 years later the results were checked again with special attention to the long-term performance of the thermal insulation measures. Laboratory tests prove that the building materials are still in good condition and that humidity has not increased with age. Cracks in the surface plaster of the compound insulation systems occurred at different frequencies and intensities and usually caused by thermal tensions. (BWI).

1992-04-01

84

Construction cost impact analysis of the U.S. Department of Energy mandatory performance standards for new federal commercial and multi-family, high-rise residential buildings  

Energy Technology Data Exchange (ETDEWEB)

In accordance with federal legislation, the U.S. Department of Energy (DOE) has conducted a project to demonstrate use of its Energy Conservation Voluntary Performance Standards for Commercial and Multi-Family High-Rise Residential Buildings; Mandatory for New Federal Buildings; Interim Rule (referred to in this report as DOE-1993). A key requisite of the legislation requires DOE to develop commercial building energy standards that are cost effective. During the demonstration project, DOE specifically addressed this issue by assessing the impacts of the standards on (1) construction costs, (2) builders (and especially small builders) of multi-family, high-rise buildings, and (3) the ability of low-to moderate-income persons to purchase or rent units in such buildings. This document reports on this project.

1993-12-01

85

Case studies and educational aids survey. A research report  

Energy Technology Data Exchange (ETDEWEB)

A survey was conducted to determine the sources of buildings energy conservation case studies and educational aids available in Canada. In total 785 consultants, educational institutions, building developers, manufacturers and government agencies were contacted. The results of this survey provide an indication of those agencies in Canada most actively involved with energy conservation in buildings, a listing of those agencies in Canada having case study information and/or educational aids materials available related to energy conservation in buildings, and a broad description of the subject area of the case studies and educational aids listed. The results of this study are intended to provide a source listing of energy conservation case studies and educational aids to the Buildings Energy Technology Transfer Program lead agencies and others conducting similar studies in the ...

1983-09-01

86

Computed tomographic findings of intrahepatic peripheral cholangiocarcinoma  

International Nuclear Information System (INIS)

Cholangiocarcinoma is synonymous with bile duct carcinoma, and can originate in a small intrahepatic bile duct (peripheral type), a major intrahepatic duct including the hepatic hills, an extrahepatic duct, or near the papilla of Vater (central type). In a sense bile duct carcinoma of the peripheral type is cholangiocarcinoma of the liver; it has the same gross configuration as hepatocellular carcinoma, resulting in difficulty to differentiate on the CT. The authors studied CT findings of 14 cases of pathologically proven peripheral type cholangiocarcinoma of the liver during the last 4 years. The results were as follows: 1. Of 14 cases, 8 were female and 6 were male, and the age ranged from 5th to 7th decades. 2. Preoperative clinical diagnosis were as follows: hepatoma 8 cases, abscess 5 cases and metastasis 1 case in order of frequency. 3. Diagnosis were confirmed by hepatic lobectomy in 7 cases, wedge resection in 5 cases and needle biopsy in 2 case. 4. Laboratory findings were not ...

1986-08-01

87

CT findings of intrahepatic cholangiocarcinoma associated with hepatolithiasis  

International Nuclear Information System (INIS)

To assess the CT findings of intrahepatic cholangiocarcinoma associated with hepatolithiasis. The CT features of 26 patients with cholangiocarcinoma and hepatolithiasis were reviewed and compared with those of 23 patients with intrahepatic stones alone, acting as control subjects. CT findings were analyzed for tumor appearance and adjacency to hepatolithiasis. We studied clinical findings, noting the presence or absence of wall thickening or soft tissue attenuation within the bile duct, the luminal diameter of dilated bile duct, and the presence of periductal enhancement, and compared these with the findings for control groups. CT images of the tumor revealed a hepatic low-attenuating mass with peripheral rim enhancement(n = 14,54 %), or periductal thickening, or low-attenuating lesions in segmental dilatation of intrahepataic bile ducts(n = 12, 46 %). Most hepatic tumors were seen in areas adjacent to hepatolithiasis, or in a bile duct. Compared with control ...

1999-09-01

88

Thermal energy considerations on solar cavity wall building  

Energy Technology Data Exchange (ETDEWEB)

The dwelling is equipped with solar collectors which heat the air circulating in the cavity walls and the space beneath the floors. The thermal aspects of such a building are described. Heat balance, losses, heating by the sun in different seasons are described. Different measures taken to reduce the energy losses are described.

1983-02-01

89

Principles of room air flow; Grundlagen der Raumluftstroemung  

Energy Technology Data Exchange (ETDEWEB)

The following subjects are dealt with: physics of indoor air flow, flow in individual rooms, exchange of air and pollution between individual building zones and with the outside world, thermal coupling with the building shell, thermal comfort and air quality, evaluation of the ventilation. figs., tabs., refs.

1994-12-31

90

Neutron data requirements for calculating transactinide isotope build-up in reactors  

International Nuclear Information System (INIS)

Based on a generalized theory of perturbations and on non-linear programming an approach to the quantitative determination of necessary accuracies for nuclear data is described. It is used to calculate transactinide isotope build-up in reactors.

1979-08-01

91

Green Building. Sustainable building in the USA and Canada; Green Building. Duurzaam bouwen in de VS en Canada  

Energy Technology Data Exchange (ETDEWEB)

First, attention is paid to the development and use of new construction techniques, including the use of new building materials, e.g. synthetic materials and the so-called steel frame method. Next, the reduction of the energy consumption during the service life of a house is discussed. The reduction can be realized by means of passive methods, e.g. improved windows, thermal insulation and design, or by means of active methods, e.g. electric load monitoring. The information in this article mainly concerns the housing construction in the USA and Canada. The purpose of this article to contribute to the discussion in the Netherlands on innovation in the building technology, e.g. formulated in the report `Bouwvisie 2010` (Vision on Buildings for the year 2010) of the Dutch Advisory Board Technology Policy for the Building Industry (ARTB, abbreviated in Dutch) and the building technology ...

1996-12-31

92

Energy Performance Contracting for New Buildings  

Wastenet

situ by isolating portions of the building envelope and performing tests .MAXIMUM ALLOWED LOAD ...and shall identify commissioning team members who will perform testing and prepare documentation.The commissioning agent may be

93

United States Transportation Command 2001 Annual ...  

Science.gov (United States)

... our architecture. Upon that foundation, we are building a set of web-based information management capabilities. These ...

2011-05-13

94

The NASA Science Internet - An Integrated Approach to Networking ...  

Science.gov (United States)

An intemted approach to building a networking infrastructure is an absolute necessiry for meeting the multidisciplinary science networking requirements of ...

95

Sheet1  

Science.gov (United States)

... 15, 14, Robert Constable, Cornell University, NY, Building Interactive Digital Libraries of Formal Algorithmic Knowledge, Navy. ...

96

Risk assessment for the SNR-300 reactor. Earthquake hazard emanating from reactor component failure  

International Nuclear Information System (INIS)

The risk analysis was carried out in consideration of conditions prevailing at the Kalkar site analogous to the investigations in phase A of DRS (German Reactor Study). Earthquake design loads include the probabilities of upper deviations of the site intensities to be expected. The calculations of dynamic loads for select buildings are made using models and computational methods. Component analyses were performed analogous to DRS for the supports of large components, supports of the roof construction of the reactor building taking into account support reserves due to plastic work capacity, wall disks in steam generator buildings and switchboard plant buildings. (DG).

97

PowerPoint Presentation  

Wastenet

facilities, building hygienic latrines and introducing regular solid waste collection systems . These methods are constantly being developed and

98

Operating buildings during temporary electricity shortages  

Energy Technology Data Exchange (ETDEWEB)

The operation of buildings can be temporarily modified to use much less electricity. These actions may be necessary during regional electricity shortages lasting anywhere from days to months. The electricity conservation measures typically involve a combination of technical modifications, temporary changes in occupant behavior, and greatly increased vigilance. At the same time, attempts to drastically reduce a building's electricity use may have unexpected consequences affecting energy use, the indoor environment, and the performance of building materials and equipment. Electricity shortfalls such as those described in this paper may occur more often as a result of climate change and liberalized electricity markets. (author)

2006-07-01

99

Distributed ontology building as practical work  

British Library Electronic Table of Contents (United Kingdom)

Ontologies ? a form of structured and logically related knowledge or classification hierarchy embedded in a computer system ? are regarded by many scientists as having enormous promise for the consistent use and re-use of data. To realise this promise, however, is not straightforward. In this paper, based on ethnographic observation, we argue that the challenges for ontology building are ?social? as much as they are technical. By this we mean the routine work undertaken in the building process and the problems and difficulties entailed can be understood in terms of the practices of knowledge workers and the practical nature of ?sorting things out?. Getting a better sense of how, in practise, this work gets done gives a sense of the main challenges of building successful ontologies and how ...

2011-01-01

100

Design Guide: Designing and Building High Voltage Power ...  

Science.gov (United States)

... Aluminum electrolytic capacitors have improved through the years. They are smaller, and equivalent series resistance (ESR) is improved. ...

1988-08-01

101

An investigation of passive ventilation cooling and control strategies for an educational building  

Energy Technology Data Exchange (ETDEWEB)

Many non-domestic buildings, built recently in the UK, use natural means to provide ventilation for indoor air quality and thermal comfort. This paper presents monitoring results obtained from such a purpose built naturally ventilated educational building. Its performance during the summer is discussed based on monitored results. Using thermal and ventilation modelling, the paper also discusses the optimisation of the building's summer performance. Recommendations on the selection of appropriate ventilation strategies in relation to the prevailing external conditions are derived and the appropriateness of the control methods is discussed. (author)

2001-02-01

102
103

A conceptual model for laboratory ventilation greenhouse gas planning  

British Library Electronic Table of Contents (United Kingdom)

There is increasing pressure to operate laboratory facilities in environmentally and financially sustainable ways. A key factor in achieving this goal is careful consideration of how energy is used by the buildings' ventilation system, both for conditioning air supplied to the laboratories and the energy used moving air through the building. Traditionally, laboratory energy use is treated as an engineering concern within the scope of the building's overall design and operation. However, this approach limits the involvement of key stakeholders in many important decisions and can lead to unexpected safety concerns for the laboratory's users. We believe that a broad view of the parties affected by a laboratory building's operations is necessary to avoid having the various stakeholders working...

2011-01-01

104

222Rn exhalation rate from Egyptian building materials using active and passive methods  

International Nuclear Information System (INIS)

... Sciences, Research Center for Radiation Protection, Chiba (Japan) Hafez,

2009-03-01

105

The building tomorrow and after..; Le batiment demain et apres-demain..  

Energy Technology Data Exchange (ETDEWEB)

During its jubilee, the French building technical and scientific centre (CSTB) has organized a colloquium about the future tendencies of buildings evolution in the 20 forthcoming years: autonomy in energy production and wastes or effluents management, reduction of water consumption and management of water, hot water production and space heating, bio-sensors for the management of indoor air-quality, control of noise environment using active acoustic systems etc.. (J.S.)

1998-01-01

106

The application of ecosystems services criteria for green building assessment  

Energy Technology Data Exchange (ETDEWEB)

In the discussion of environmental architecture, we are conjoining two disciplines, the subject of architecture and that of ecology. At their best, green buildings are examples of applied ecology, where designers understand the constitution, organization, and structure of ecosystems, and the impacts of architecture are considered from an environmental perspective. By utilizing the concepts, methods, and language of ecology, designers can create architecture that intentionally engages the natural systems of a site. The establishment of assessment criteria implies the definition of building design criteria. If we establish criteria that are based on our best scientific understanding of environmental capacity, we will begin to develop a building stock that is sustainable. To do this we must quantify the link between the resulting environmental impacts and their cause in building production and use. This is ...

2004-10-01

107

Super-ventilation in commercial buildings; Surventilation des locaux tertiaires  

Energy Technology Data Exchange (ETDEWEB)

The preliminary results of a feasibility study of nighttime and/or daytime accelerated ventilation for reducing or even avoiding air conditioning energy consumption in commercial buildings, is presented. The first part of the study is based on computerized simulations and in-situ experimentations which are described. The second part is aimed at determining technological limitations to the various components and optimizing building environmental quality in terms of energy conservation, acoustics and air quality

1995-09-01

108

Probabilistic Seismic Risk Analysis of a Wolsung NPP Containment Building for Near Fault Ground Motions  

Energy Technology Data Exchange (ETDEWEB)

In this study, a probabilistic seismic risk analysis of the Wolsung NPP containment building was performed by a seismic hazard analysis and a seismic fragility analysis based on the nonlinear dynamic time-history analyses. The conventional seismic fragility analysis of the safety related structures in a NPP have been performed by using the linear elastic analysis results. The probabilistic seismic risk of the containment building was 5.19e-8.

2006-07-01

109

Probabilistic Seismic Risk Analysis of a Wolsung NPP Containment Building for Near Fault Ground Motions  

International Nuclear Information System (INIS)

In this study, a probabilistic seismic risk analysis of the Wolsung NPP containment building was performed by a seismic hazard analysis and a seismic fragility analysis based on the nonlinear dynamic time-history analyses. The conventional seismic fragility analysis of the safety related structures in a NPP have been performed by using the linear elastic analysis results. The probabilistic seismic risk of the containment building was 5.19e-8.

2006-05-25

110

Hawaii demand-side management resource assessment. Final report, Reference Volume 1: Building prototype analysis  

Energy Technology Data Exchange (ETDEWEB)

This report provides a detailed description of, and the baseline assumptions and simulation results for, the building prototype simulations conducted for the building types designated in the Work Plan for Demand-side Management Assessment of Hawaii`s Demand-Side Resources (HES-4, Phase 2). This report represents the second revision to the initial building prototype description report provided to DBEDT early in the project. Modifications and revisions to the prototypes, based on further calibration efforts and on comments received from DBEDT Staff have been incorporated into this final version. These baseline prototypes form the basis upon which the DSM measure impact estimates and the DSM measure data base were developed for this project. This report presents detailed information for each of the 17 different building prototypes developed for use with the DOE-21E program (23 ...

1995-04-01

111

Informing the decision makers on the cost and value of green building  

Energy Technology Data Exchange (ETDEWEB)

This paper seeks to challenge the traditional way in which we assess the value of green buildings in terms of their environmental friendliness, energy efficiency and whole life cost. In the UK, quantity surveyors (or cost consultants) have a perception that more energy efficient and environmentally friendly buildings cost between 5% and 15% more to build from the outset. This common assumption is not backed up by recent research and should be questioned. Construction professionals need to be informed of the whole life cost and environmental impact of buildings so that they can encourage key stakeholders to make more sustainable choices. These emerging issues together with practical tools are considered with case studies from recent projects. (Author)

2000-09-01

112

Building design using the energy nomographs  

Energy Technology Data Exchange (ETDEWEB)

Today's building industry is promoting the use of renewable sources of energy to heat, cool, and illuminate commercial buildings. Societies such as the International Solar Energy Society sponsor conferences such as this one to share knowledge and experience in the area of solar energy. However, the technologies presented here assume a need for heating, cooling or illumination. A simple technique is presented for determining the actual heating, cooling, and lighting requirements for commercial buildings, and for reducing those requirements through proper building design before applying solar technologies. The energy nomographs are a graphic energy design tool developed to aid designers in making cost effective decisions about energy alternatives early in the design process. Reducing loads at this point can help reduce the expense of a passive or active solar system which is usually sized to meet ...

1983-06-01

113

Air conditioning in high rise buildings; conditionnement d'air dans les immeubles de grande hauteur  

Energy Technology Data Exchange (ETDEWEB)

This book brings together the 103 presentations given at the 2. conference of the international institute of refrigeration (IIF/IIR) about air conditioning in high rise office buildings. The main themes are: design of air conditioning equipment for high buildings; air quality and thermal comfort inside these buildings; constraints and possible improvements of the refrigeration equipment used; energy conservation; fire protection and smokes detection. All themes are presented both on the technical and economical points of view and concern more particularly the buildings of Chinese cities. This publication is available both on the book and CD-Rom forms. (J.S.)

2000-07-01

114

The market for green building in developed Asian cities. The perspectives of building designers  

Energy Technology Data Exchange (ETDEWEB)

Green building (GB) is part of the concept of promoting sustainability. Although GB and the concept of sustainability are well studied for environmental concerns, their business rationale and related social concerns have not been fully explored or widely accepted by the parties involved in the building sector. In this study, the situation of GB market in relation to the general building market is reviewed and the business rationales of stakeholders to invest in the GB market have been investigated from the perspective of building designers. In addition, the factors that enhance the popularity of GB have been explored and the obstacles that hinder its market have been examined. The data are collected by a questionnaire survey covering building designers in Hong Kong and Singapore, the cities that are categorized as economically developed cities in Asia. After data analysis of the ...

2009-08-15

115

Investigation of the impact of electricity rate and mix on optimum green building design  

Energy Technology Data Exchange (ETDEWEB)

The basic principle of the green building philosophy is to design buildings that consider environmental performance. Residential and commercial buildings in Canada consume about 30 per cent of the total secondary energy use and are responsible for approximately 29 per cent of carbon dioxide equivalent greenhouse gas emissions and many other wastes. An optimization model was developed which minimizes life cycle cost and life cycle environmental impact. The model distinguishes different energy sources and incorporates their impacts, such as resource depletion, global warming and acidification. The model also considers design variables such as window type, orientation, building orientation, window-to-wall ratio, wall type and roof type. The model can be used to identify optimum green building designs for given conditions. The model uses expanded cumulative exergy consumption as the ...

2004-07-01

116

Building America Performance Analysis Procedures for Existing Homes  

Energy Technology Data Exchange (ETDEWEB)

Because there are more than 101 million residential households in the United States today, it is not surprising that existing residential buildings represent an extremely large source of potential energy savings. Because thousands of these homes are renovated each year, Building America is investigating the best ways to make existing homes more energy-efficient, based on lessons learned from research in new homes. The Building America program is aiming for a 20%-30% reduction in energy use in existing homes by 2020. The strategy for the existing homes project of Building America is to establish technology pathways that reduce energy consumption cost-effectively in American homes. The existing buildings project focuses on finding ways to adapt the results from the new homes research to retrofit applications in existing homes. Research activities include a combination of computer ...

2006-05-01

117

An investigation into the profitability of energy management in office buildings  

Energy Technology Data Exchange (ETDEWEB)

This thesis examines the costs and benefits of energy management in office buildings and investigates the relationships between operating costs, space lease contracts, and building value. Energy management be building owners and managers begins with monitoring and analysing building energy, use and continues by reducing energy consumption through operating procedure changes, equipment replacement and control personnel training and continued monitoring. The cost to complete energy management projects in 12 British Columbia office buildings is analyzed. The average before-tax internal rate of return for the 12 energy management programs was 22.1% on total expenditures of Canadian $1.2 million. Nine of the buildings are owned and occupied by the provincial government, and the return on investment directly benefits the public. However, in the three prvately owned ...

1988-01-01

118

The CO{sub 2} gasification kinetics of olive residue  

Energy Technology Data Exchange (ETDEWEB)

Orujillo, sometimes called wood matter from pressed oil-stone (WPOS) is a residue from the olive oil mill industry. The generation of this biomass residue is concentrated in small areas allowing its use as fuel for medium size gasification and combustion plants. Rates of gasification of WPOS char were measured in a TGA at various temperatures (800-850-875-900-950{sup o}C), CO{sub 2} partial pressures (0.20-0.35-0.50 bar) and CO partial pressures (0.0-0.20 bar). The experiments were carried out with a monolayer bed of very fine particles well exposed to the gas so as to minimise mass and heat transfer resistances. Two kinetic models, the nth order model and Langmuir-Hinshelwood model, have been used to fit with the reactivity data. For pure CO{sub 2} experiments the kinetic parameters of nth order model were E=133 kJ/mol and n=0.43. The Langmuir-Hinshelwood kinetic model clearly describes the observed CO inhibition effect on the CO{sub 2} gasification.(author)

2003-02-01

119

Some medical applications of thermomechanically treated titanium nickelide  

Energy Technology Data Exchange (ETDEWEB)

An original device and a method of its application for restoring of the function of relatively incompetent valves (both patented) are elaborated. Application of the new device allows to lower the difficulty of surgical treatment, to decrease the duration of operation and post-operative period. The long-term results of six-year long experience of its application are presented. The patients examination after 2,5-3,0-year post-operation period shows perfect vein valve correction. A device for stone extraction from tubular organs (patented) fabricated with titanium nickelide superelastic alloy is presented. The new suggested design is free of the drawback inherent in the previous one. The working element of the device is formed as a truncated cone or a truncated cone coaxial with the cylinder (the previous design was formed as a full cone) that prevents overstraining and residual strain accumulation during the manipulation process. Since the first publication the ...

2001-11-01

120

Silicate bonded ceramics of laterites  

International Nuclear Information System (INIS)

Sodium silicate is vacuum impregnated in bauxite waste (red mud) at room temperature to develop ceramics of mechanical properties comparable to the sintered ceramics. For a concentration up to 10% the fracture toughness increases from 0.12 MNm"-"3"/"2 to 0.9 MNm"-"3"/"2, and the compressive strength from 7 MNm"-"2 to 30 MNm"-"2. The mechanical properties do not deteriorate, when soaked in water for an entire week. The viscosity and the concentration of the silicate solution are crucial, both for the success of the fabrication and the economics of the process. Similar successful results have been obtained for bauxite and lime stone, even though the latter has poor weathering properties. With scanning electron microscopy and energy dispersive analysis, an attempt is made to identify the crystals formed in the composite, which are responsible for the strength. The process is an economic alternative to the sintered ceramics in the construction industry in the tropical ...

2006-06-16

121

Problems of waste disposal in the handling of natural radioactive material not subject to authorisation  

International Nuclear Information System (INIS)

With the exception of some minerals, the specific activity of natural radioactive material is below 370 Bq/g, their handling thus not being subject to authorization or the duty of reporting according to section 4 para. 2 of the Radiological Protection Ordinance. Moreover, there is required no handling license for prospecting, mining and processing of radioactive minerals; they are subject to the procedures for the plans of operation of the mining laws of the Federal States. License-free handling of natural radioactive material may result in the production of radioactive waste, the disposal of which must be authorized according to sect. 47 of the Radiological Protection Ordinance if the specific activity exceeds the free amounts of column 4 in Table IV of Appendix IV by a factor of 10"-"4/g. This inconsistency is discussed by means of the following examples: (1) fly ash and slag from coal power plants, (2) flue dust from sintering plants, (3) red mud from aluminium production, (4) ...

1980-05-01

122

Metallic and non-metallic properties of one-dimensional peanut-shaped fullerene polymers  

British Library Electronic Table of Contents (United Kingdom)

Some kind of one-dimensional (1D) peanut-shaped fullerene polymers (PSFPs) exhibit metallic properties, but their occurrence conditions are not yet clarified. By using the VASP (Vienna ab-initio simulation package) with density functional theory (DFT) and projector augmented wave (PAW) method, we have performed first-principles electronic structure calculations of four basic 1D PSFPs, T1, T2, T6, and T7 (the name of T1-T6 is the same as that of Wang et al. [9]) and two associated 1D PSFPs, T1SW1 and T6SW that are created by generalized Stone-Wales transformation (GSW) from T1 and T6. We found that almost regular six-membered rings connected throughout the tube are necessary to get metallic properties for the 1D PSFPs, although there may be several other conditions to expect metallic proper...

2011-01-01

123

Investigation of a mineral melting cupola furnace. Part II. Mathematical modeling  

Energy Technology Data Exchange (ETDEWEB)

A mathematical model of a mineral melting cupola furnace for stone wool production has been developed for improving cupola operation. The 1-D, first-engineering-principles model includes mass and heat balances for the gas phase, five solid phases, and four liquid phases. The gas and solid/liquid phases flow countercurrently. Seven chemical reactions account for the conversions of coke, iron oxide, limestone, and gaseous species. The heterogeneous reactions of coke conversion are limited by both kinetics and mass transport. Heat transfer between phases is modeled including both convection and radiation. The model predicts gas concentrations; mass flow rates; and temperature profiles of the solid, melt, and gas in the cupola, as well as heat loss to the water-cooled walls. Inputs to the model include the coke, rock, and blast air properties, the blast air amount, and the coke percentage in the charge. The unknown model parameters are estimated on the basis of ...

2003-12-24

124

Sustainable development in city districts: BaLaLuZ project - Building ecology; Schlussbericht 'Gebaeudeoekologie' - Phase 1  

Energy Technology Data Exchange (ETDEWEB)

This final report for the Swiss Federal Office of Energy (SFOE) is one of a series of reports concerning municipal development in various cities in Switzerland. The four city districts involved include Basel (Gundeldinger Feld), Lausanne (Bellevaux), Lucerne (Basel-/Bernstrasse) and Zurich (Werdwies). This paper takes a look at aspects of building ecology. In the four areas, the following building types and projects were examined with respect to their ecology: Basel: conversion of commercial premises to a community centre, Lausanne and Lucerne: Enhancement of residential areas, Zurich: a new residential building. Criteria examined include general building ecology, building materials, raw materials, toxic substances, recycling, maintenance and deconstruction, energy for heating and hot water, grey energy, electricity, ground usage, water, wastes and public infrastructure. Knowledge ...

2004-07-01

125

Increasing security of supply: the search for stable models of new nuclear build in the European Union  

International Nuclear Information System (INIS)

Full text. This research assesses models for new nuclear build in European Union (EU) member states to find the most stable form. The countries examined in this study are the United Kingdom and Romania. The results attest that due to various historical, political, competition, and electricity market structural conditions Romania and the United Kingdom have emerged with different models for new build nuclear projects. This paper begins with an assessment of the effects on the nuclear sector from energy, environmental and competition legislation in the EU. Then the political and economic climate of the aforementioned EU member states is completed. Following this an overview of the market structure of the electricity sector in those respective countries is conducted. Then the key research on the models and the phases of new nuclear build are explored. The research concludes each model has transcended from different political ...

2009-10-12

126

Guidelines for indoor air hygiene in school buildings  

Energy Technology Data Exchange (ETDEWEB)

The new guidelines for indoor air hygiene in school buildings are intended as a response to current requirements in school practice. The recommendations aim to help to avoid mistakes in modernising school buildings and to provide hygiene-specific support in planning of new school buildings. The guidelines are laid out as follows: (a) In the general section the targets of the guidelines and the target groups are addressed. The current indoor hygiene situation in German schools is described, followed by the parameters with regard to peripheral issues which will not be dealt with further; (b) Part A deals with the hygiene requirements in the practical running of schools. Besides general requirements for maintenance and operation the important issues of cleaning and ventilation are considered, as well as minor building works; (c) Part B provides an overview of important chemical and biological contaminants ...

2008-08-15

127

Characteristics of seismic ground motions and responses of base isolated buildings in Japan  

International Nuclear Information System (INIS)

In this paper, the authors describe the characteristics of design seismic input motions and recently observed seismic records of base isolated buildings in Japan. First, we describe some seismic design spectra for building structures which were adopted. Then we show response spectra and energy spectra of observed records obtained during two recent major earthquakes (The 1995 Hyogo-ken Nanbu Earthquake and the 2003 Tokachi-oki Earthquake), which demonstrate the effectiveness of base isolation against large amplitude earthquake ground motion. We also introduce the responses of base isolated buildings during some earthquakes including the Tokachi-oki Earthquake. These data were gathered through questionnaires sent to many engineers who had conducted response observations of base isolated buildings. Last, an example of a base isolated building on soft ground is shown. We point out the ...

2007-04-26

128

Airflow modelling and fire smoke propagation in the new Ecole Polytechnique building  

Energy Technology Data Exchange (ETDEWEB)

A study was conducted to predict indoor ventilation, smoke movement and fire propagation in a new building currently under construction at the Ecole Polytechnique de Montreal. It was conducted in response to concerns regarding the impact that air quality, in normal operation conditions, and smoke concentration, in the event of a fire, may have on occupants of a building. A detailed three-dimensional model of the new building was constructed using the NURBS-based modeler, Rhino. Simulations of fire propagation and airflow ventilation were performed in different areas of the building. The flow pattern data was analyzed using the computational fluid dynamics (CFD) program called FLUENT. It predicted air flow conditions and estimated the mean age of air (MAA) in the room. Real-world geometries, such as diffuser inlets, have a significant impact on overall fluid flow behaviour and are necessary for this type ...

2005-07-01

129

Vibration experiment for a three-loop PWR reactor building  

Energy Technology Data Exchange (ETDEWEB)

Forced vibration experiment has been conducted for the reactor building of Sendai Unit 1 nuclear power plant. The beam vibrational behaviors of the outer shielding building and the internal concrete structure have been observed by using a 50 tf vibration for low frequency region, and a 10 tf vibration for high frequency region, respectively. The outline of the experimental methods, the data handling system and the major results of experiment are described. The experimental results were simulated by an analytical model. The proper vibrational frequency and the vibration modes obtained by the analysis were compared with those obtained by the experiment. By these comparisons, the adequacy of the analytical method employed for the design was confirmed.

1983-12-01

130

Radiant heating and cooling, displacement ventilation with heat recovery and storm water cooling: An environmentally responsible HVAC system  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the design, operation, and performance of an HVAC system installed as part of a project to demonstrate energy efficiency and environmental responsibility in commercial buildings. The systems installed in the 2180 m{sup 2} office building provide superior air quality and thermal comfort while requiring only half the electrical energy of conventional systems primarily because of the hydronic heating and cooling system. Gas use for the building is higher than expected because of longer operating hours and poor performance of the boiler/absorption chiller.

1998-12-31

131

Facility Safety Plan B360 Complex Biohazardous Operations CMLS-412r0  

Science.gov (United States)

This Addendum to the Facility Safety Plan (FSP) 360 Complex describes the safety requirements for the safe conduct of all biohazardous research operations in all buildings within the 360 complex program areas. These requirements include all the responsibilities and authorities of building personnel, operational hazards, and environmental concerns and their controls. In addition, this Addendum prescribes facility-specific training requirements and emergency controls, as well as maintenance and quality assurance requirements for ES&H-related building systems.

2007-01-08

132

Energy Savings Modeling and Inspection Guidelines for Commercial Building Federal Tax Deductions, Second Edition  

Energy Technology Data Exchange (ETDEWEB)

This document provides guidance for modeling and inspecting energy-efficient property in commercial buildings for certification of the energy and power cost savings related to Section 179D of the Internal Revenue Code enacted in Section 1331 of the 2005 Energy Policy Act and noted in Internal Revenue Service Notice 2006-52. Specifically, Section 179D provides federal tax deductions for energy-efficient property related to a commercial building's envelope; interior lighting; heating, ventilating, and air conditioning; and service hot water systems.

2007-05-01

133

Energy Savings Modeling and Inspection Guidelines for Commercial Building Federal Tax Deductions  

Energy Technology Data Exchange (ETDEWEB)

This document provides guidance for modeling and inspecting energy-efficient property in commercial buildings for certification of the energy and power cost savings related to Section 179D of the Internal Revenue Code enacted in Section 1331 of the 2005 Energy Policy Act and noted in Internal Revenue Service Notice 2006-52. Specifically, Section 179D provides federal tax deductions for energy-efficient property related to a commercial building's envelope; interior lighting; heating, ventilating, and air conditioning; and service hot water systems.

2007-02-01

134

Building ventilation, state of the art, prospective; Ventilation des batiments etat des lieux, prospective  

Energy Technology Data Exchange (ETDEWEB)

This conference is composed of 21 communications and 21 posters in the domain of building ventilation and indoor air quality; the main themes are: indoor air quality assessment and optimization; performance enhancement and optimization of ventilation systems and equipment; ventilation systems for renovated and rehabilitated buildings; French and European regulations, standardizations and certifications; experimental and numerical simulation studies concerning ventilation systems, air flow, temperature distribution, air quality, thermal comfort and ventilation-induced acoustic levels

1995-10-01

135

An estimation method for basemat uplift behavior of nuclear power plant buildings  

Energy Technology Data Exchange (ETDEWEB)

It is important to accurately estimate the effects of strong earthquake motions on the basemat uplift behavior and structural responses for the seismic design of nuclear power plant buildings. In this paper, an analysis model which describes the soil part using the 3 dimensional FEM was proposed to be used when the ground contact ratio is low, and the validity of this model was confirmed. Furthermore, investigations using the model were carried out where the attaching force under the basemat was taken into account, in order to more realistically estimate the basemat uplift behavior. The effects in the case of the building being embedded were also investigated.

2007-07-15

136

An estimation method for basemat uplift behavior of nuclear power plant buildings  

International Nuclear Information System (INIS)

It is important to accurately estimate the effects of strong earthquake motions on the basemat uplift behavior and structural responses for the seismic design of nuclear power plant buildings. In this paper, an analysis model which describes the soil part using the 3 dimensional FEM was proposed to be used when the ground contact ratio is low, and the validity of this model was confirmed. Furthermore, investigations using the model were carried out where the attaching force under the basemat was taken into account, in order to more realistically estimate the basemat uplift behavior. The effects in the case of the building being embedded were also investigated.

2007-07-01

137

Wind-induced contaminant transport in near-surface soils with application to radon entry into buildings  

Energy Technology Data Exchange (ETDEWEB)

Indoor air exposures to gaseous contaminants originating in soil can cause large human health risks. To predict and control these exposures, the mechanisms that affect vapor transport in near-surface soils need to be understood. In particular, radon exposure is a concern since average indoor radon concentrations lead to much higher risks than are generally accepted for exposure to other environmental contaminants. This dissertation examines an important component of the indoor radon problem: the impacts of wind on soil-gas and radon transport and entry into buildings. The research includes experimental and modeling studies of wind`s interactions with a building`s superstructure and the resulting soil-gas and radon flows in the surrounding soil. In addition to exploring the effects of steady winds, a novel modeling technique is developed to examine the impacts of fluctuating winds on soil-gas and radon transport.

1996-05-01

138

View Transcript (111 Kb PDF) - NASA  

Science.gov (United States)

Sep 8, 2005 ... one of the headquarters buildings here at Stennis, took off .... Also, they have a joint task force, that the ...

139

The uses of system integration. In the field of tension between building safety and automation; Nutzen der Systemintegration. Im Spannungsfeld von Gebaeudesicherheit und Gebaeudeautomation  

Energy Technology Data Exchange (ETDEWEB)

There are no 'intelligent' buildings but only 'intelligently controlled' buildings. Intelligent control requires communication between technical facilities, which in turn requires building automation and system integration. [German] Es gibt keine ''intelligenten'', sondern nur ''intelligent betriebene'' Gebaeude. Mit dieser Feststellung ist die Vorbedingung festgelegt, dass Gebaeude ein gewerkeuebergreifendes System benoetigen, das die Komponenten miteinander kommunizieren laesst. Dafuer eignet sich die Gebaeudeautomation. Damit diese ihre Aufgaben erfuellen kann, bedarf es der Systemintegration. (orig.)

2001-07-01

140

The informationist: building evidence for an emerging health profession*  

UK PubMed Central (United Kingdom)

Background:To encourage evidence-based practice, an Annals of Internal Medicine editorial called for a new professional on clinical teams: an informationist trained...Full Text Available

2010-04-01

141

Technical Basis for Radiological Workplace Air Monitoring and Sampling for the River Corridor Project 300 area  

Energy Technology Data Exchange (ETDEWEB)

This report documents the technical basis by which the workplace air monitoring and sampling program is operated in the 324 and 327 Buildings.

2000-01-17

142

Stationary low power reactor No. 1 (SL-1) accident site decontamination & dismantlement project  

Science.gov (United States)

The Army Reactor Area (ARA) II was constructed in the late 1950s as a test site for the Stationary Low Power Reactor No. 1 (SL-1). The SL-1 was a prototype power and heat source developed for use at remote military bases using a direct cycle, boiling water, natural circulation reactor designed to operate at a thermal power of 3,000 kW. The ARA II compound encompassed 3 acres and was comprised of (a) the SL-1 Reactor Building, (b) eight support facilities, (c) 50,000-gallon raw water storage tank, (d) electrical substation, (e) aboveground 1,400-gallon heating oil tank, (f) underground 1,000-gallon hazardous waste storage tank, and (g) belowground power, sewer, and water systems. The reactor building was a cylindrical, aboveground facility, 39 ft in diameter and 48 ft high. The lower portion of the building contained the reactor pressure vessel surrounded by gravel shielding. Above the pressure vessel, in the center portion ...

1995-11-01

143

Solid Waste & Financial Assistance Program  

Science.gov (United States)

This program deals with solid waste disposal with topics/services covering: Reusable Building Materials and Large Household Items Exchange, Beneficial Use Determination, Biosolids, Certification, Compost Facil...

144

Scenarios of application of energy certification procedure for residential buildings in Lebanon  

International Nuclear Information System (INIS)

This paper describes the results of a French-Lebanese scientific cooperation, between 2001 and 2005, about 'Rational use of energy in the residential buildings in Lebanon and adaptation of an energy certification procedure'. The aim of this project is to promote the energy efficiency in the existing residential buildings in Lebanon, using an energy certification procedure, and to evaluate the energy certification foresight with prospective methods. The paper first describes an energy investigation in Lebanese residential buildings, and the energy certification procedure. It presents the foresight methodology implemented to identify the key variables and the actors. Finally, the paper exposes the morphological method which allows to elaborate three scenarios of energy performance certification. These scenarios are presented in order to provide a decision making for the actors of the Lebanese energy policy.

2007-06-01

145

Rich Baldwin - NASA  

Science.gov (United States)

Rich Baldwin. Phone : 301-286-3031. Email : Building/Office : 22/163. Mailing Address : NASA/GSFC, Code 921, Greenbelt, MD 20771 ...

146

Power Analyzer for Pocket Computing (PAPC)  

Science.gov (United States)

... Those functions are fundamental routines to build a power model for more complex circuits or functional blocks. ... 21 of 54 6. Memory Power Model ...

2004-01-01

147

Nuclear waste plans enter critical phase  

Energy Technology Data Exchange (ETDEWEB)

A brief article considers the possible result of the enquiry into Nirex`s plan to build an underground rock laboratory at Sellafield in relation to radioactive waste disposal in the UK. (UK).

1996-10-31

148

NASA - NASA Selects Pennsylvania Firm to Build Liquid Nitrogen Plant  

Science.gov (United States)

Sep 21, 2006 ... NASA has selected Air Products and Chemicals, Inc., Allentown, Pa., to design, furnish and install a plant to produce liquid nitrogen for ...

149

Lipid Peroxidation and Antioxidant Defense ... - LSDA - Experiment  

Science.gov (United States)

Apr 21, 2011 ... The system of lipid peroxidation reacts regularly to adverse effects and results in enhancement of lipid peroxidation and build-up of LPO ...

150

Energy policy for integrating the building environmental performance model of an air conditioned building in a subtropical climate  

Energy Technology Data Exchange (ETDEWEB)

For an air conditioned building, the major electricity consumption is by the heating, and air conditioning (HVAC) system. As energy saving strategies may be in conflict with the criteria of indoor air quality and thermal comfort, a concept of the building environmental performance model (BEPM) has been developed to optimize energy consumption in HVAC systems without any deterioration of the indoor air quality and thermal comfort. The BEPM is divided into two main modules: the adaptive comfort temperature (ACT) module and the new demand control ventilation (nDCV) module. This study aims to enhance and prompt the conventional operation of the air side systems by incorporating temperature reset with the adaptive comfort temperature control and the new demand control ventilation system in high rise buildings in Hong Kong. A new example weather year (1991) was established as a reference to compute the energy use of HVAC systems ...

2006-09-15

151

Development of grid-connected photovoltaic systems  

International Nuclear Information System (INIS)

The activities and the policy in the Netherlands regarding the development of the title systems since 1990 are briefly outlined, focusing on the use of PV-systems in buildings. 5 figs., 1 tab.

152

Capturing the Daylight Dividend  

Energy Technology Data Exchange (ETDEWEB)

Capturing the Daylight Dividend conducted activities to build market demand for daylight as a means of improving indoor environmental quality, overcoming technological barriers to effective daylighting, and informing and assisting state and regional market transformation and resource acquisition program implementation efforts. The program clarified the benefits of daylight by examining whole building systems energy interactions between windows, lighting, heating, and air conditioning in daylit buildings, and daylighting's effect on the human circadian system and productivity. The project undertook work to advance photosensors, dimming systems, and ballasts, and provided technical training in specifying and operating daylighting controls in buildings. Future daylighting work is recommended in metric development, technology development, testing, training, education, and outreach.

2006-04-30

153

Building the Perfect Parasite: Cell Division in Apicomplexa  

UK PubMed Central (United Kingdom)

Apicomplexans are pathogens responsible for malaria, toxoplasmosis, and crytposporidiosis in humans, and a wide range of livestock diseases. These unicellular eukaryotes are stealthy invaders, sheltering...Full Text Available

2007-06-01

154

Building connections - Transition from TN-C to TN-S five-core building connection cable solves problems; Hausanschluss: Wechsel von TN-C auf TN-S  

Energy Technology Data Exchange (ETDEWEB)

This article discusses the use of five-core cables to provide utility customers with the best possible prerequisites for trouble-free operation of electrical installations and equipment. The TN-S system in buildings and the new TN-S-five-core house-connection cable for connections between the mains distribution point and buildings is introduced. The long-term target of providing TN-S-systems in power distribution even as far as the local transformer is also discussed. The advantages of the system are discussed and various configurations for different types of supply are described.

2005-07-01

155

AutoCAD as a graphic interface for tsbi3. Working report; AutoCAD som grafisk graenseflade til tsbi3; Arbejdsrapport  

Energy Technology Data Exchange (ETDEWEB)

The overall aim is to develope programme modules for a Danish integrated computer system for projecting buildings and to ensure that Danish programmes are compatible with international systems. The programmes to be integrated here were AutoCAD and SCRIBE-Models and the simulation programme tsbi3 for the calculation of indoor climate conditions, power demand and energy consumption in buildings. For the calculation of humidity and temperature conditions in constructions a certain amount of integration is carried out with the MATCH programme (Moisture And Temperature calculations for Constructions of Hygroscopic materials). The activities embodied in the pilot projects are described in this working report in addition to individual computer programmes and prototypes, and examples and diagrams are presented. The programmes described deal with handling design elements in relation to AutoCAD designs, and the formatting of a ...

1993-03-01

156

A simple method for measuring the radon diffusion coefficient and exhalation rate from building materials  

International Nuclear Information System (INIS)

The widespread use of building materials with relatively high radium concentrations may increase population exposure. A method is presented for measuring effective diffusion coefficients and exhalation rates of radon from such materials. Equations for use in the experimental determination of these values are obtained theoretically. The experimental set-up consists of a container which is hermetically sealed to a slab of the building material. Nitrogen is blown through the container and then through an ionization chamber which is connected to an electrometer and X-Y plotter, and the radon concentration is measured continuously. Exhalation rates of radon from some major building materials measured by this method will be used as reference levels. The method can also be used to determine other properties such as porosity. (author).

157

A - Z Index : Environmental Energy Technologies Division  

Science.gov (United States)

Buildings Energy-Efficient Research Laboratories Energy Efficiency in Federal Facilities Energy Efficiency Standards Group Energy Efficient Windows Collaborative Energy &...

2011-07-15

158

The method and results of measurements of "2"2"2Rn emanation from building materials  

International Nuclear Information System (INIS)

The method and results are presented of measurements of the coefficients of "2"2"2Rn emanation from samples of fly- ashes and slag and other commonly used building materials. A chamber was used for electrostatic collection of "2"2"2Rn decay products. The coefficients of emanation ranged from 0.2% (fly- ashes) to 21.3% (phosphogipsum from phosphorit). (author).

1979-01-01

159

Survey of naturally radioactive level of some new type wall materials  

International Nuclear Information System (INIS)

Naturally occurring radioactive materials (NORM) in seven new type wall materials were surveyed. The radioactivity was determined with HPGe-#gamma# spectrometer. The red mud has the highest radioactivity concentration, followed by slag building blocks, fly-ash building blocks (bricks), gangue bricks and light weight board materials, gypsum blocks. Fly-ash and slag contain higher NORM, which contributes the major part of the radioactivity in new wall materials. (authors)

2006-09-01

160

Studies of neural networks for engine control: application to the electromechanical valves engine; Etudes des reseaux de neurones pour le controle moteur: application a soupapes electromecaniques  

Energy Technology Data Exchange (ETDEWEB)

This paper deals with the control of an electromechanical valves engine. The control uses neural networks in order to build a non-linear model of engine filing which depends on the driven inlets. The aim is to build this real-time model and to integrate this model to a control system which performs an iterative inversion. (J.S.)

1997-12-31

161

Performance estimates for attached-sunspace passive solar heated buildings  

Energy Technology Data Exchange (ETDEWEB)

Performance predictions have been made for attached-sunspace types of passively solar heated buildings. The predictions are based on hour-by-hour computer simulations using computer models developed in the framework of PASOLE, the Los Alamos Scientific Laboratory (LASL) passive solar energy simulation program. The models have been validated by detailed comparison with actual hourly temperature measurements taken in attached-sunspace test rooms at LASL.

1980-01-01

162

New construction of the health centre in Mannheim. Bivalent geothermal energy supply for an inner-city building; Neubau eines Aerztehauses in Mannheim. Bivalente geothermische Energieversorgung fuer ein Innenstadtgebaeude  

Energy Technology Data Exchange (ETDEWEB)

An inner-city development with pile foundations as well as the proximity to the river Neckar with a groundwater flow offered ideal conditions for this new building in Mannheim in order to heat and cool geothermally. Already with the planning phase, detailed numerical flow computations were necessary in order to prove the functionality of the energy concept.

2010-07-01

163

Measurements of radioactivity in Jamaican building materials and gamma dose equivalents in a prototype red mud house  

International Nuclear Information System (INIS)

Concentrations of 226Ra, 232Th, and 40K measured in bauxite waste, local building materials, and soils are presented and used in model equations to estimate the effective gamma dose-equivalent increments over background in the center of a standard-sized room in a prototype house. Calculated and measured values compare reasonably well.

164

Introduction to the special issue on decision support in medicine  

British Library Electronic Table of Contents (United Kingdom)

Information technology plays an important role in medicine because of the advanced decision support systems (DSS) it can provide. We provide an overview of the building blocks necessary for a medical decision support system and introduce seven research articles in this special issue that describe the development and evaluation of individual medical DSS building blocks or complete medical DSS.

2007-01-01

165

Green design focus: Energy efficiency and environmental responsibility  

Energy Technology Data Exchange (ETDEWEB)

This case study illustrates how an existing building can be transformed into a sustainable, green facility through teamwork. This multi-purpose building comprises office space, combustion testing facilities, and microwave communications center. The paper discusses internal systems design, indoor air quality, commissioning, economics, operations and maintenance, and monitoring.

1998-02-01

166

Green Growth  

Wastenet

... Social Capital Social capital describes circumstances in which individuals and organisations can use membership in groups and networks to secure benefits. Connections within and between networks reinforce the belief that these social networks have a value and can be used as a platform for further social progress. In this light, natural capital and social capital are closely related, and policies that build or destroy one often build ...

167

Geodesy problems in nuclear power plant construction  

Energy Technology Data Exchange (ETDEWEB)

The special geodetic problems encountered during the construction of the Paks nuclear power plants are treated. The main building with its hermetically connected components including the reactor, the steam generators, the circulation pumps etc. impose special requirements on the control net of datum points. The geodesy tasks solved during the construction of the main building are presented in details.

1981-01-01

168

Estimating demolition cost of plutonium buildings for dummies  

Energy Technology Data Exchange (ETDEWEB)

The primary purpose of the Rocky Flats Field Office of the US Department of Energy is to decommission the entire plant. In an effort to improve the basis and the accuracy of the future decommissioning cost, Rocky Flats has developed a powerful but easy-to-use tool to determine budget cost estimates to characterize, decontaminate, and demolish all its buildings. The parametric cost-estimating tool is called the Facilities Disposition Cost Model (FDCM).

2000-07-01

169

Engineering Assistance and sustainable development; Ingenierie conseil et developpement durable  

Energy Technology Data Exchange (ETDEWEB)

Since many years, people take care of hazardous consequences of a non controlled economic growth and the sustainable development concept gains on one. This situation leads to consequences in the building industry and in the energy policy: buildings insulation in consideration, demand of consultants. In this framework, the partnership between Gaz De France and CICF has to be built. (A.L.B.)

2002-07-01

170

Energy management  

Energy Technology Data Exchange (ETDEWEB)

This document deals with energy management in buildings. It presents the conditions for a good implementation of energy management. These conditions include the total involvement of the management and the training of the staff. The structure of this implementation is presented together with the tools for an efficient energy management. Eventually, information on air quality and comfort in buildings is provided, as well as the management of complaints linked to them. (TEC). 1 tab.

1993-12-31

171

Drilling on the basis of reliable data. Geothermal exploration; Bohren nach verlaesslichen Planungsdaten. Geothermie  

Energy Technology Data Exchange (ETDEWEB)

Geothermal heat pump systems necessitate a comprehensive approach to geology and building facilities in order to be energetically useful and efficient. Cooperation with geothermal experts should be sought at an early projecting stage in order to obtain reliable data. Geothermal data and the technical facilities of the building must be matched for the project to be both effective and efficient. (orig.)

2008-01-15

172

Design and procurement report for the FFTF fuel handling systems bottom-loading transfer cask  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) bottom-loading transfer cask (BLTC) system is designed to provide ex-vessel fuel transfers of irradiated reactor components between the reactor containment building and the LMFBR shipping cask in the reactor service building. This system is being procured from National Lead Industries, Wilmington, Delaware, under management of Aerojet Manufacturing Company.

1975-11-16

173

April 2008 - British Minister for Science and Innovation I Pearson MP, visiting the ATLAS surface building and underground area with Spokesperson P. Jenni and Adviser J. Ellis.  

CERN Multimedia

April 2008 - British Minister for Science and Innovation I Pearson MP, visiting the ATLAS surface building and underground area with Spokesperson P. Jenni and Adviser J. Ellis.

2008-01-01

174

The cooperative housing society Vaarst Vestervang - green building; Andelsboligforeningen Vaarst Vestervang - groent byggeri  

Energy Technology Data Exchange (ETDEWEB)

Vaarst Vestervang (Denmark) comprises 16 villas and 1 communal building. The complex was designed by the inhabitants themselves with the aim of polluting the environment as little as possible. The land area constitutes 69.000 square meters where it is possible to grass animals. The document reports a measuring programme concerning the overall heat consumption as one of the main aims of the inhabitants is to save energy and thus contribute to the protection of the environment. The capacity of the solar collectors predominantly used in the building complex was 235 kWh/m{sup 2}. Supplementary heating is provided by boilers fired with wood. The measuring system is described in detail. Tables show the influence of heat transmission losses, ventilation, airing out of rooms, the angle of the sun`s rays within the buildings and heating needs on energy consumption. Energy consumption data is presented in relation to the forms of ...

1993-10-01

175

The ''passivhaus'' standard: from energy efficiency to 'green' building; Le standard ''passivhaus'': de la performance energetique a la construction ''verte''  

Energy Technology Data Exchange (ETDEWEB)

The German voluntary standard 'Passivhaus' (passive house) leads to buildings with practically no energy consumption. The first residential buildings of this type were built in 1998 and the first tertiary buildings in 2000. Such a passive house must fulfill 5 efficiency criteria: annual space heating needs {<=} 15 kWh/m{sup 2}, U{sub v} envelope coefficient lower than 0.15 W/(m{sup 2}.K), U{sub v} of openings lower than 0.8 W/(m{sup 2}.K), airtightness {<=} 0.6 volume/hour, and total energy needs (space heating, hot water, ventilation, lighting and domestic uses) measured at the meter lower than 42 kWh/m{sup 2}.year. This article makes a status of the effective efficiency of existing passive buildings both in the residential and tertiary sectors and presents some possible ways of improvement. (J.S.)

2005-10-01

176

Sustainable schools. Better than traditional schools?  

Energy Technology Data Exchange (ETDEWEB)

In the United Kingdom several educational buildings were built in the last decades with a strong environmental ethos, real icons of a new generation of low-energy sustainable buildings. For some of the buildings the performance was assessed. Also in the Netherlands several new concepts were developed for sustainable schools during the last years. This is an interesting topic as many of those schools had problems concerning energy efficiency, indoor air quality and thermal comfort. In the case of sustainable schools much effort was put into the design process of the schools to try to find better solutions to face the problems of the traditional designs. This resulted in different solution concepts, which raises the question which are better school concepts. From the literature three evaluations from the UK and one overview of five sustainable educational buildings from the Netherlands are given, which ...

2008-10-15

177

Simplified procedure for sizing and analyzing thermal energy storage in commercial and institutional buildings and generation of plots for North Carolina  

Energy Technology Data Exchange (ETDEWEB)

The objective of the project was to provide a readily understandable and usable methodology for preliminary analysis of the economic benefit that can accrue from the use of thermal energy storage for building heating and cooling. The procedure was to be capable of providing an estimate of cooling plant and storage size, as well as the monthly savings that can be saved. The research focused on the development of a procedure for a limited class of commercial and institutional buildings in North Carolina. A simplified procedure for analyzing the potential for using thermal energy storage (TES) in such buildings in North Carolina was developed. The procedure developed consists of charts and nomographs that can be used for estimating the size of TES systems, and for estimating the monthly demand savings. The monthly demand savings can be combined with the applicable rate schedule to determine the annual cost savings. An overview ...

1981-06-30

178

Radon-mitigation in buildings  

International Nuclear Information System (INIS)

From the indoor radon problem arises a great challenge for the radiation protection of the population. The soil can be considered as the only source for high radon concentrations in buildings. The contribution of common building materials to high indoor concentrations with a range of 30 Bq/m"3 is negligible low. Therefore building materials for radon mitigation should be judged by their tightness against diffusive radon and not by their radon exhalation rate. Also isolation materials for mitigation should be radon tight. The radon diffusion coefficient describes the physical processes in relatively homogeneous samples. The diffusion coefficient D and the diffusion length R are very exactly determined by a self engineered measuring method. The range of D reaches from D = (0.0005 to 2.35) . 10"-"6 m"2/s for building materials and from D = (0.07 to < 10"-"6) . 10"-"6 m"2/s for isolation materials. ...

179

Natural or unnatural ventilation? Sustainable environmental management in non-residential buildings  

Energy Technology Data Exchange (ETDEWEB)

Recent interest in ecologically sustainable design (ESD) has once more focussed attention upon environmental management in buildings. This paper explores the application of both air conditioning and natural ventilation in creating more sustainable non-residential buildings. In the non-residential sector the level of debate surrounding sustainable forms of environmental control and management has been disappointing. It has largely been based upon the rather simplistic argument that air conditioning is bad and natural ventilation is good and thus the only sustainable solution is naturally ventilated buildings. The paper advances the view that for both designers and managers of buildings the problem is more complex than a simple choice between air conditioning and natural ventilation. It begins with a reassessment of conventional ideas of thermal comfort and the organization of the workplace and argues ...

1995-12-31

180

Dynamic interactions and competing objectives in multifamily green building design  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the challenges involved in the construction of a mid-rise housing development in Boston, Massachusetts, during which the development team elected to upgrade the initial design criteria from Minimum Building Code to Energy Star and Leadership in Energy and Environmental Design (LEED) certification. The various constraints imposed on the development were discussed, including constraints imposed by the involvement of substantial public funds as well as the constraints imposed by various funding sources that were approached to leverage energy efficiency and green building investment via competitive grant solicitations. Building owner and utility cost management priorities were outlined along with details of central mechanical system selection. Issues concerning isolation and compartmentalization were examined along with indoor pollution source control. A building load analysis was ...

2005-07-01

181

Development of flame retardant PV module encapsulants: Volume 1. Final report  

Energy Technology Data Exchange (ETDEWEB)

This Phase 1 final report covers the work performed by Springborn Testing and Research, Inc., for the period October 1, 1997 to June 30, 1998 under the Department of Energy Cooperative Agreement Number DE-FC36-97GO10255, entitled Development of Flame Retardant PV Module Encapsulants. While use of roof-mounted arrays has always been an attractive means of deploying PV, only within recent years have such building integrated concepts (BIPV) found renewed interest among module makers and end-users. Prior to building integrated and rooftop applications, flammability requirements for modules have not been a great industry concern. However, with growing interest in BIPV and the requirement for building code requirements for commercial and industrial structures, flammability issues have become a barrier to entry for many module constructions into this potentially huge domestic market for PV. The overall goal of the 3 phase PV BONUS ...

1998-06-01

182

Monthly report of activities: APRIL 1, 1969  

Science.gov (United States)

This is the first of a series of monthly reports summarizing the status of the work of the National Accelerator Laboratory. This first report will cover developments since the publication of the Design Report in January. Authorization hearings were held before the Joint Committee on Atomic Energy on February 21, 1968. Dr. Wilson described the plans and designs of the Laboratory. The present plan of the Laboratory is that the Village of Weston will be utilized for office, laboratory, and shop space during construction. The Laboratory business office is already occupying several houses. The linac section is occupying three houses for offices and construction of an 8,000 sq ft laboratory building for linac work is almost complete. Another house is being used and a 4,500 sq ft inflatable building is being constructed for model-magnet and vacuum testing. Other temporary buildings will be constructed for use by other sections. We ...

1968-04-01

183

Healthy Buildings and Green Building Rating Systems; Gezond bouwen en duurzaamheidslabels  

Energy Technology Data Exchange (ETDEWEB)

The awareness of health issues related to buildings has heightened past decades. Indoor Environmental Quality (IEQ) has been addressed in most Green Building Rating Systems nowadays. This article analyses the scope of IEQ (Indoor Environmental Quality) within Rating Systems GPR Gebouw, BREEAM-NL (Dutch version of Building Research Establishment's Environmental Assessment Method) and LEED (Leadership in Energy and Environmental Design). Each Rating System allocates health aspects. However, none of these Rating Systems addresses a complete set of relevant aspects. High ratings do not guarantee healthy buildings. It is concluded that, in general, credits for energy efficiency do not interfere with credits for enhanced indoor environmental quality. [Dutch] Gezondheidsaspecten van gebouwen hebben afgelopen decennia steeds meer en integraler aandacht gekregen. In de instrumenten GPR Gebouw, BREEAM-NL ...

2010-11-15

184

Advanced Lighting Program Development (BG9702800) Final Report  

Energy Technology Data Exchange (ETDEWEB)

The report presents a long-range plan for a broad-based, coordinated research, development and market transformation program for reducing the lighting energy intensities in commercial and residential buildings in California without compromising lighting quality. An effective program to advance lighting energy efficiency in California must be based on an understanding that lighting is a mature field and the lighting industry has developed many specialized products that meet a wide variety of light needs for different building types. Above all else, the lighting field is diverse and there are applications for a wide range of lighting products, systems, and strategies. Given the range of existing lighting solutions, an effective energy efficient lighting research portfolio must be broad-based and diverse to match the diversity of the lighting market itself. The belief that there is one solution--a magic bullet, such as a better lamp, for ...

1998-02-01

185

Vibration experiment for a three-loop PWR reactor building  

International Nuclear Information System (INIS)

Forced vibration experiment has been conducted for the reactor building of Sendai Unit 1 nuclear power plant. The beam vibrational behaviors of the outer shielding building and the internal concrete structure have been observed by using a 50 tf vibration for low frequency region, and a 10 tf vibration for high frequency region, respectively. The outline of the experimental methods, the data handling system and the major results of experiment are described. The experimental results were simulated by an analytical model. The proper vibrational frequency and the vibration modes obtained by the analysis were compared with those obtained by the experiment. By these comparison, the adequacy of the analytical method employed for the design was confirmed. (Aoki, K.).

1983-01-01

186

Two-phase application of multi-objective genetic algorithms in green building design  

Energy Technology Data Exchange (ETDEWEB)

The application of multi-objective genetic algorithms for green building design in two phases were presented in order to better help designers in the decision-making process. The purpose is to minimize two conflicting criteria: the life-cycle cost and the life-cycle environmental impact. Environmental impact criteria examined include energy and non-energy natural resources, global warming, and acidification. Variables focus on building envelope-related parameters. The application of multi-objective genetic algorithms is divided into two phases. The first phase intends to help designers in understanding the trade-off relationship between the two conflicting criteria. The second phase intends to refine the performance region that is of the designer's interest. The results after the two-phase application of the multi objective genetic algorithm were then presented. 13 refs., 4 tabs., 3 figs.

2005-07-01

187

The Seismic Risk Explorer - A Scenario Tool for Assessing Seismic Risk  

Science.gov (United States)

The Seismic Risk Explorer, an extension for ArcGIS Desktop developed by cedim AG, is a tool for computing the seismic risk, i.e. damage on residential buildings and thereby caused monetary losses for earthquake scenarios. It is based on the research results of the CEDIM (Center for Disaster Management and Risk Reduction Technology) research center, located at the Karlsruhe Institute of Technology (KIT) and the GeoForschungsZentrum (GFZ) in Potsdam. With this software tool seismic scenarios can be simulated for a given magnitude, depths and location. The seismic intensity, the resulting mean damage ratio for residential buildings and the seismic risk, expressed as the monetary loss caused by an earthquake can be computed downscaled to communities, postcode areas or even single buildings. Interested end-users are especially insurance companies, but also public authorities which may use the tool for risk management issues.

2009-04-01

188

Studies on natural radioactivity of some egyptian building materials  

International Nuclear Information System (INIS)

Using high-resolution y-rays spectrometry, the natural radioactivity of 14 samples of natural and o manufactured Egyptian building materials have been investigated. The samples were collected from local market and construction sites. From the measured gamma-ray spectra, specific activities were determined. The radium equivalent activity in each sample was estimated. Radiological evaluations of these materials indicate that all materials meet the external gamma-ray dose limitation. Calculation of concentration indices by assuming a Markkanen room model is constructed from these materials, to find the excess gamma-ray dose taken over that received from the outdoors. The Austrian Standard ONORM S 5200 is used in testing the building materials.

2004-02-24

189

Sound climate installations. Gezonde klimaatinstallaties  

Energy Technology Data Exchange (ETDEWEB)

An uncomfortable thermal climate, draft complaints and a bad airquality are often related to the climate installation. To avoid badfunctioning of the system a number of preconditions has to be fulfilledwith regard to design, planning and execution, adjustments, completion,control, maintenance and management of the installations. First threetypes of health problems in buildings are shortly discussed: buildingrelated illness, sick building syndrome and building or installationrelated complaints. Then some functions of the climate installationsare described: air filtration, filter classes and filter quality, aswell as investment costs for better filters. Next the causes for thecomplaints are dealt with: air conditioning, ventilation, air quality,and temperatures. Subsequently health affecting aspects in relation tothe climate systems are discussed: outdoor air pollution,microorganisms, bacteria (legionella pneumophila), ...

1989-10-01

190

Response characteristics of base-isolated structure with silicone rubber bearings  

International Nuclear Information System (INIS)

More than sixty base-isolated buildings have been built in Japan. A number of base-isolation systems were considered in our research, which was intended to establish the effectiveness of base-isolation systems. We conducted research on silicone rubber bearings. Generally, silicone rubber is durable and its characteristics are not dependent on the temperature within the relevant design range. The first part of the report covers material and elements testing. After the bearings were installed in the building, we performed forced vibration tests in both the horizontal and vertical directions. These test results form the next section. After several experiments, we carried out earthquake observations. We report on the effectiveness of the system in reducing response acceleration during a small displacement. This system was installed in the building in March 1992

1993-08-15

191

Renewable energy [systems in buildings]; Duurzame energie [in gebouwen  

Energy Technology Data Exchange (ETDEWEB)

As a result of a lower value of the energy efficiency coefficient (EPC) for houses and the implementation of the Energy Performance Building Directive (EPBD), both in 2006, the interest in applying renewable energy systems is growing. Therefore, this issue is dedicated to renewable energy and related energy systems. [Dutch] Het begrip 'duurzaam' is van toepassing op twee pijlers: een pijler betreft het gebruik van duurzame materialen, de tweede pijler is duurzame energie. Door verlaging van de Energieprestatiecoefficient (EPC) voor woningen per 2006 en de invoering van de Europese richtlijn Energy Performance Building Directive (EPBD) in 2006, krijgt duurzame energie een nieuwe impuls. Reden voor de redactie van ThemaTech om deze aflevering te wijden aan duurzame energie en verwante ystemen.

2005-05-15

192

Recent advances in silicon-germanium alloy technology and an assessment of the problems of building the modules for a radioisotope thermoelectric generator  

International Nuclear Information System (INIS)

This paper reviews the state of the art of silicon-germanium technology and assesses the problems of building thermoelectric modules in Europe, based upon silicon-germanium alloys, for use in multihundred watt radio-isotope thermoelectric generator. The generator developed in the United States for the International Solar Polar mission has been used as a reference system. The essential features of an alternative system, which employs thermocouples fabricated from improved silicon-germanium alloys based upon a design by the Fairchild Space and Electronics Company, is also described. It is concluded that although the fabrication of reliable electrical contacts will present a major problem, the technology is available in Europe to build thermoelectric modules similar to those developed for the International Solar Polar mission. (orig.).

193

Malaspina University-College's green building strategy  

Energy Technology Data Exchange (ETDEWEB)

This brochure describes the strategy employed by the administration of Malaspina University--College in Nanaimo, British Columbia, to implement energy-efficient plans and integrating systems and plans that would allow the institution to consume less energy, fewer resources and improve the health and well-being of its students and staff. An assessment study to identify the most problematic areas, and to develop a prioritizing strategy for their replacement was the first step, followed by rigorous adherence to a 10- year cyclical replacement schedule. The program includes replacement of rooftop ventilation units, installation of high-performance glazing units to replace single-glazed windows, implementation of an Energy Management System to monitor heating, ventilating and air conditioning systems, and a Power Smart New Building Design and Building Improvements Program. The combined cost avoidance associated with these projects is estimated to ...

2000-01-01

194

International heliophysical year and basic space science in West Asia  

Science.gov (United States)

This paper summarizes the IHY and BSS activities in West Asia and their importance in many Arab countries, such as Algeria, Egypt, Iraq, Jordan, Kuwait, Qatar, Saudi Arabia, UAE, etc. BSS future plans for some of these countries are as follows: It is proposed by the astronomers from the Arabian Gulf Region to build the Gulf Observatory on top of Jabal Shams (2980 msl) which will have a 2-3 m optical telescope. Libya signed a contract with a French company for building an observatory which will have a 2-m optical robotic telescope. It is also proposed to rebuild the Iraqi National Astronomical Observatory (INAO) which was destroyed during the two wars. It is planned to build a 5-6 m optical telescope and a small solar telescope on the top of Korek mountain, which has excellent observing conditions.

2007-12-01

195

Indoor climate seminar; Sisaeilmastoseminaari  

Energy Technology Data Exchange (ETDEWEB)

The national energy research programme LVIS-2000: Future Building Services is concerned with the control of energy use and indoor climate in buildings of the future. The projects were presented at a one day seminar arranged by the Laboratory of Heating and Ventilation of the Technical Research Centre in Finland which is coordinating the programme. The presentations at the seminar were: Impurity emission from materials, Building materials and indoor air quality, analysis of organic compounds in indoor air, effect of the return air, effect of the return air on health and comfort, electric heating as an indoor climate factor, calculations of air flows in ventilated rooms, effect of energy saving measures on hospital hygiene, application of modern aerosol measurement technique on indoor climate research.

1989-12-31

196

Impact of the FY 2005 Building Technologies Program on United States Employment and Earned Income  

Energy Technology Data Exchange (ETDEWEB)

The Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy (EERE) is interested in assessing the potential economic impacts of its portfolio of subprograms on national employment and income. A special purpose version of the IMPLAN input-output model called ImBuild II is used in this study of all 21 Building Technologies Program subprograms in the EERE final FY 2005 budget request to the Office of Management and Budget on February 2, 2004. Energy savings, investments, and impacts on U.S. national employment and earned income are reported by subprogram for selected years to the year 2030. Energy savings and investments from these subprograms have the potential of creating a total of 396,000 jobs and about $5.6 billion in earned income (2003$) by the year 2030.

2004-08-31

197

HVAC for energy showcase  

Energy Technology Data Exchange (ETDEWEB)

Southern California Gas Co.`s (SoCalGas) Energy Resource Center (ERC) in Downey, Calif. is a 45,000 ft{sup 2} (4,181 m{sup 21}) conference and education center created to help energy decision-makers find the most energy-efficient, cost-effective and environment-sensitive solutions to their energy requirements. The center has 36,000 ft{sup 2} (3,344 m{sup 2}) of remodeled space and 9,000 ft{sup 2} (836 m{sup 2}) of new space, all designed to showcase the latest energy-efficient and environment-sensitive technologies. The building is one of the 25 buildings in the US to be designated as Energy Star Showcase buildings by the US Environmental Protection Agency.

1997-07-01

198

Fixation of heavy contaminants of a dirty bomb attack: Studies with uranium and metal simulants  

British Library Electronic Table of Contents (United Kingdom)

Asphalt emulsions were evaluated as a means to immobilize radiological contaminants deposited on urban surfaces after a dirty bomb attack. Contaminated surfaces would be sprayed with thin coatings of asphalt emulsion to encapsulate the radioactive particles until the site can be safely remediated. This research investigated applications of an asphalt emulsion (Topein C, Encapco Technologies, LLC, Napa, CA) to treat (zero-valent) iron, lead, and uranium powders on various building material surfaces. Initial studies found that some of the building materials (limestone, concrete, and metal) reacted with the emulsion producing gas bubbles, which formed 0.001 to 1 cm vesicles in the cured asphalt emulsion. These vesicles, however, did not expose the building material surface, and the reaction a...

2007-01-01

199

Field tests on partial embedment effects (embedment effect tests on soil-structure interaction)  

International Nuclear Information System (INIS)

A series of Model Tests of Embedment Effect on Reactor Buildings has been carried out by the Nuclear Power Engineering Corporation (NUPEC), under the sponsorship of the Ministry of International Trade and lndustry (MITI) of Japan. The nuclear reactor buildings are partially embedded due to conditions for the construction or building arrangement in Japan. It is necessary to verify the partial embedment effects by experiments and analytical studies in order to incorporate the effects in the seismic design. Forced vibration tests, therefore, were performed using a model with several types of embedment. Correlated simulation analyses were also performed and the characteristics of partial embedment effects on soil-structure interaction were evaluated. (author)

1993-08-15

200

Effect of Coating of Ammonium Perchlorate with Fluorocarbon on Ballistic and Sensitivity Properties of AP/Al/HTPB Propellant  

British Library Electronic Table of Contents (United Kingdom)

Fluorocarbon polymers are used to enhance thermal stability and electrostatic protection of composite propellant compositions. A precipitation technique has been developed to coat ammonium perchlorate (AP) using a copolymer of hexafluoropropylene and vinylidene fluoride (HFP-VF) with the help of solvent-counter solvent method. The coated AP has been used to prepare propellant compositions in different ratio based on hydroxyl terminated polybutadiene (HTPB), aluminium powder along with uncoated AP and studied for viscosity build-up and visco-elastic behaviour as well as mechanical, ballistic, thermal and sensitivity properties keeping 86% solid loading. The data on viscosity build-up indicate that as the percentage of viton coated AP increases end of mix viscosity and viscosity build-up inc...

2009-01-01

201

Development of standard solutions for the Minergie standard; Standardloesungen - Entwicklung von Standardloesungen fuer den Minergie-Standard  

Energy Technology Data Exchange (ETDEWEB)

This final report for the Swiss Federal Office of Energy (SFOE) examines a project that aimed to define standard solutions for use in buildings built to meet Minergie low energy consumption standards. These standard solutions are to provide a way of meeting Minergie standards in an easy way and thus further the use of the standard and also assure quality at the same time. The report describes how the solutions were developed on the basis of a selection of existing Minergie buildings. For various combinations of heating systems - wood, wood/solar, heat pumps (brine-water and air-water), gas/solar and oil/solar - the appropriate U-values for various building elements are listed. The resulting Minergie forms and guides are listed.

2003-07-01

202

Architects and engineers guide to energy conservation in existing buildings  

Energy Technology Data Exchange (ETDEWEB)

The manual enhances and simplifies the work of those architects and engineers whose practice includes the analysis and modification of existing buildings to reduce both fuel consumption and operating costs. A review of the principles of energy use and conservation is given. The manual also provides a step-by-step methodology for assessing and improving the year-round energy performance of buildings, as well as a series of forms, charts, and nomographs designed to serve as day-to-day tools in the energy professional's toolbox. After a cost-benefit analysis is prepared for each conservation opportunity, the owner will be able to implement decisions based on projected energy savings and calculate investment costs, operational changes, and payback periods. Each of these considerations is accorded a detailed treatment.

1980-02-01

203

Air conditioning in high rise buildings; Conditionnement d'air dans les immeubles de grande hauteur  

Energy Technology Data Exchange (ETDEWEB)

This two-tomes book brings together the 108 presentations given at the first conference of the international institute of refrigeration (IIF/IIR) about air conditioning in high rise office buildings. The main themes are: general design and control systems, including split systems, radiant panels, fluctuating and gravity ventilation etc..; energy consumption, optimization and heat recovery; cold storage for peak shaving, including ice slurry circulation; indoor air quality; fire and smokes protection, protection against chimney effects and lighting spots; use of fuzzy logic and of neural networks. It includes also a description of the high rise building situation and works in progress in China, Japan and in some other countries. (J.S.)

1997-07-01

204

Use of the ADINA (Automatic Dynamic Incremental Nonlinear Analysis) computer code on a COSA II (Computer Codes for Salt) benchmark computer case of the local area - progress report 1990  

International Nuclear Information System (INIS)

The COSA II (computer codes for salt) benchmark problem has been pursued with the ADINA (Automatic Dynamic Incremental Nonlinear Analysis) program code. With the use of this, the code should be validated by means of experimental data and the ability to reproduce real-life calculation results of the KfK (Kernforschungszentrum Karlsruhe/Nuclear Research Center in Karlsruhe) should be proven. A successful validation of the code then forms the foundation stone for the ability to use different calculation problems in the final (ultimate) storage. This also accompanies the consequent reaction of replacing the STEALTH (Solids and Thermal Hydraulics Code for EPRI Adapted from LAGRANGE TOODY and HEMP) program which has a number of program-specific weaknesses compared to the ADINA computer code. In order to reproduce the approximate values from the KfK, the same values have been used. Differences were evident in the discretion and the selection of the initial values for ...

205

Treatment of Malignant Biliary Obstruction with a PTFE-Covered Self-Expandable Nitinol Stent  

Energy Technology Data Exchange (ETDEWEB)

We wanted to determine the technical and clinical efficacy of using a PTFE-covered self-expandable nitinol stent for the palliative treatment of malignant biliary obstruction. Thirty-seven patients with common bile duct strictures caused by malignant disease were treated by placing a total of 37 nitinol PTFE stents. These stents were covered with PTFE with the exception of the last 5 mm at each end; the stent had an unconstrained diameter of 10 mm and a total length of 50 80 mm. The patient survival rate and stent patency rate were calculated by performing Kaplan-Meier survival analysis. The bilirubin, serum amylase and lipase levels before and after stent placement were measured and then compared using a Wilcoxon signed-rank test. The average follow-up duration was 27.9 weeks (range: 2 81 weeks). Placement was successful in all cases. Seventy-six percent of the patients (28/37) experienced adequate palliative drainage for the remainder of their lives. There were no immediate ...

2007-10-15

206

The economic geology of clays/shales raw materials for the ceramics industry in Lebanon  

International Nuclear Information System (INIS)

Author.Field, laboratory and market studies are a must for proper evaluation of natural resources for the mineral industry of lebanon. Sites selectively convenient to the existing major Lebanese ceramics industry centered in the Beqa'a region, were investigated as to their geology, geography and economic character. The raw materials are shales, mud stones, siltstones and other argillaceous rocks of Jurassic to Cretaceous age coming from selective sites in south and central Lebanon. The finished products include wall, floor, roofing tiles, pipes, sanitary ware, pottery and brick specimens. Differential thermal analysis, scanning electron microscopy, firing and physico-chemical tests and analyses characterized the raw materials into two major groups: the suitable are siliceous argillaceous rocks and unsuitable calcareous argillaceous rocks. The suitable group is divided into two varieties. The first is dominantly a disordered Kaolinite with low drying and firing ...

207

Physical mechanisms of transient enhanced dopant diffusion in ion-implanted silicon  

Energy Technology Data Exchange (ETDEWEB)

Implanted B and P dopants in Si exhibit transient enhanced diffusion (TED) during annealing which arises from the excess interstitials generated by the implant. In order to study the mechanisms of TED, transmission electron microscopy measurements of implantation damage were combined with B diffusion experiments using doping marker structures grown by molecular-beam epitaxy (MBE). Damage from nonamorphizing Si implants at doses ranging from 5{times}10{sup 12} to 1{times}10{sup 14}/cm{sup 2} evolves into a distribution of {l_brace}311{r_brace} interstitial agglomerates during the initial annealing stages at 670{endash}815{degree}C. The excess interstitial concentration contained in these defects roughly equals the implanted ion dose, an observation that is corroborated by atomistic Monte Carlo simulations of implantation and annealing processes. The injection of interstitials from the damage region involves the dissolution of {l_brace}311{r_brace} defects during Ostwald ripening with an ...

1997-05-01

208

Physical mechanisms of transient enhanced dopant diffusion in ion-implanted silicon  

International Nuclear Information System (INIS)

Implanted B and P dopants in Si exhibit transient enhanced diffusion (TED) during annealing which arises from the excess interstitials generated by the implant. In order to study the mechanisms of TED, transmission electron microscopy measurements of implantation damage were combined with B diffusion experiments using doping marker structures grown by molecular-beam epitaxy (MBE). Damage from nonamorphizing Si implants at doses ranging from 5x10"1"2 to 1x10"1"4/cm"2 evolves into a distribution of #left brace#311#right brace# interstitial agglomerates during the initial annealing stages at 670 endash 815 degree C. The excess interstitial concentration contained in these defects roughly equals the implanted ion dose, an observation that is corroborated by atomistic Monte Carlo simulations of implantation and annealing processes. The injection of interstitials from the damage region involves the dissolution of #left brace#311#right brace# defects during Ostwald ripening with an activation ...

209

Intrahepatic peripheral cholangiocarcinoma; dynamic features of CT scans  

International Nuclear Information System (INIS)

To elucidate the dynamic features of CT scans in peripheral cholangiocarcinoma for the differentiation of this tumor from various primary hepatic neoplasms. Materials were 24 cases of pathologically confirmed peripheral cholangiocarcinoma. Contrast enhancement patterns of central and peripheral portion of the masses were analyzed at three phases including arterial dominant(22), tissue equilibria(24), and postequilibria(9). Other associated CT findings and laboratory data were analyzed. Serum total bilirubin was mostly below 2 mg/dl(22/24), hepatitis B surface antigen was positive in only 9%, serum alphafetoprotein was elevated in 18%, carcinoembryonic antigen in 47%, cancer antigen 19-9 in 60%. In the arterial dominant image(22), 50% of the cases showed peripheral hyperdensity and 50% total hypodensity. In the tissue equilibrial images(24), 63% showed total hypodensity, 25% peripheral hyperdensity, and 13% total isodensity. In the postequilibrial images(9), 45% showed peripheral ...

1995-05-01

210

Hepatic abscess versus peripheral cholangiocarcinoma: Sonographic differentiation  

International Nuclear Information System (INIS)

To find out the sonographic findings that are useful to differentiate hepatic abscess from peripheral cholangiocarcinoma. Twenty-two hepatic abscesses and 22 peripheral cholangiocarcinomas which had been confirmed histologically were included in this study. Objective points were echo characteristics of the lesion, internal septation, presence of peripheral low echoic rim, demarcation from normal liver(well or poorly defined), posterior enhancement, multiplicity, dilatation of bile duct(obstructive or non-obstructive), intrahepatic duct stone, pleural effusion, and intra-abdominal fluid collection. Echo characteristics of the lesion were classified in-to four types. Type I; Predominantly echogenic with hypoechoic portion, type II; Echogenic without hypoechoic portion, type III; Predominantly hypoechoic with echogenic portion, type IV; Hypoechoic without echogenic portion. 1)Nine abscesses and 2 peripheral cholangiocarcinomas were type I(p=0.037), 2)One abscess and ...

2000-12-01

211

Frontopolar and anterior temporal cortex activation in a moral judgment task. Preliminary functional MRI results in normal subjects  

International Nuclear Information System (INIS)

The objective was to study the brain areas which are activated when normal subjects make moral judgments. Ten normal adults underwent BOLD functional magnetic resonance imaging (fMRI) during the auditory presentation of sentences that they were instructed to silently judge as either 'right' or 'wrong'. Half of the sentences had an explicit moral content ('We break the law when necessary'), the other half comprised factual statements devoid of moral connotation ('Stones are made of water'). After scanning, each subject rated the moral content, emotional valence, and judgment difficulty of each sentence on Likert-like scales. To exclude the effect of emotion on the activation results, individual responses were hemo dynamically modeled for event-related f MRI analysis. The general linear model was used to evaluate the brain areas activated by moral judgment. Regions activated during moral judgment included the frontopolar cortex (FPC), medial frontal gyrus, right ...

2001-09-01

212

CT characterization of bile duct dilatation: Differential diagnosis of obstructive jaundice  

Energy Technology Data Exchange (ETDEWEB)

Each disease affecting the bile ducts tends to produce characteristic pattern of biliary dilatation: recurrent pyogenic cholangitis causes dilatation and straightening of the larger (central) intrahepatic ducts: clonorchiasis causes dilatation of the smaller (peripheral) intrahepatic ducts; and carcinoma along the extrahepatic ducts causes (proportional) dilatation and tortuosity of both larger and smaller intrahepatic ducts. To evaluate the specificity of the pattern and morphology of the dilated biliary tree on CT scans (CT characterization) three independent radiologists who were unifamiliar with the cases were asked to classify 62 CT scans in patients with obstructive jaundice. The case population consisted of 14 cases with recurrent pyogenic cholangitis, 18 cases with clonorchiasis and 30 cases with carcinoma along the extrahepatic ducts, which were intermixed randomly. Classification was made only on the basis of CT characterization: those scans showing primary lesions, i.t., ...

1992-07-15

213

CT characterization of bile duct dilatation: Differential diagnosis of obstructive jaundice  

International Nuclear Information System (INIS)

Each disease affecting the bile ducts tends to produce characteristic pattern of biliary dilatation: recurrent pyogenic cholangitis causes dilatation and straightening of the larger (central) intrahepatic ducts: clonorchiasis causes dilatation of the smaller (peripheral) intrahepatic ducts; and carcinoma along the extrahepatic ducts causes (proportional) dilatation and tortuosity of both larger and smaller intrahepatic ducts. To evaluate the specificity of the pattern and morphology of the dilated biliary tree on CT scans (CT characterization) three independent radiologists who were unifamiliar with the cases were asked to classify 62 CT scans in patients with obstructive jaundice. The case population consisted of 14 cases with recurrent pyogenic cholangitis, 18 cases with clonorchiasis and 30 cases with carcinoma along the extrahepatic ducts, which were intermixed randomly. Classification was made only on the basis of CT characterization: those scans showing primary lesions, i.t., ...

1992-07-01

214

Buried soils of Late Quaternary moraines of the Wind River Mountains, Wyoming  

Energy Technology Data Exchange (ETDEWEB)

Buried soils occur on kettle floors of four Pinedale moraine catenas of the western Wind River Mountains of Wyoming. Radiocarbon ages from bulk samples of Ab horizons indicate the soils were buried during the mid-Holocene. Soils on kettle floors have silty A and Bw horizons that overlie buried A and B horizons that also formed in silt-rich sediments. Crests and backslope soils also have A and Bw horizons of sandy loam formed over 2BCb and 2Cb horizons of stony coarse loamy sand. Recent data show the silty textures of the A and B horizons are due to eolian silt and clay from the Green River Basin just west of the mountains. The buried soils appear to represent alternate periods of erosion and deposition on the moraines during the Holocene. The original soils developed on higher slopes of the moraines were eroded during the mid-Holocene and the 2BC and 2C horizons exposed at the surface. Eroded soil sediments were transported downslope onto the kettle floors. Following erosion, silt-rich ...

1992-01-01

215

University of Tennessee deploys force10 switch for CERN work  

CERN Multimedia

"Force20 networks, the pioneer in building and securing reliable networks, today announced that the University of Tennessee physics department has deployed the C300 resilient switch to analyze data form CERN's Large Hadron Collider." (1/2 page)

2007-01-01

216

Total Synthesis and Evaluation of C26-Hydroxyepothilone D Derivatives for Photoaffinity Labeling of ?-Tubulin  

UK PubMed Central (United Kingdom)

Three photaffinity labeled derivatives of epothilone D were prepared by total synthesis, using efficient novel asymmetric synthesis methods for the preparation of two important synthetic building...Full Text Available

2010-01-01

217

The evolving environmental marketplace, using green to make green[An introduction to the U.S. Green Building Council, Performance Rating Systems, LEED as a benchmarking tool in the United States and green economics  

Energy Technology Data Exchange (ETDEWEB)

Using an economic perspective, it is possible to make a case for green buildings and green development practices by placing emphasis on Energy Efficiency and Environmental Design. Several case studies have demonstrated that green buildings save money through reduced consumption of natural resources, electricity and gas both at the building site and at the source of energy. Sound environmental practices and energy efficiency measures improve the environmental conditions throughout the state by reducing power plant emissions and reducing operations and maintenance budgets in the state. The author presented a case study where a green development project was guided and monitored using the Environmental Performance Rating System called Leadership in Energy and Environmental Design (LEED), version 2.0. The work was registered to achieve LEED certification. A brief study on current construction related costs was also included. 2 ...

2003-07-01

218

The effects of ventilation, filtration, and outdoor air on the composition of indoor air at a telephone office building  

Energy Technology Data Exchange (ETDEWEB)

Sensors installed at a telephone office building in Neenah, WI, continuously monitor 24 parameters related to the operation of the building's heating, ventilating, and air conditioning (HVAC) system. This data is stored in a dedicated minicomputer and can be retrieved, in various formats, for subsequent analyses. For more than a year, we have measured indoor and outdoor concentrations of both fine and coarse airborne particles, their chemical constituents, and volatile organic compounds at this same location. Using this data, we have examined the composition of the indoor air as it correlates to the composition of the outdoor air and the various HVAC operating parameters. The steady-state indoor concentrations of the particles, particulate constituents, and organic vapors can be explained in the context of a mass balance model. This model can also be used to calculate the rate at which selected chemicals are generated within the ...

1989-01-01

219

The Development and Evolution of Division of Labor and Foraging Specialization in a Social Insect (Apis mellifera L.)  

UK PubMed Central (United Kingdom)

How does complex social behavior evolve? What are the developmental building blocks of division of labor and specialization, the hallmarks of insect societies? Studies have revealed the developmental...Full Text Available

2006-01-01

220

Technique of moving picture overlapping for view simulation by means of the moving picture processing; Dogazo kaiseki ni motozuku keikan simulation no tame no dogazo goseiho  

Energy Technology Data Exchange (ETDEWEB)

This paper proposes a technique of moving picture overlapping for view simulation by means of the moving picture processing. The continuous pictures of actual natural view gotten from video and the pictures of building structure made by computer graphics (CG) were overlapped. The CG pictures of building structure model were made considering the camera parameters, such as position and direction of camera. In order to analyze the continuously changing camera parameters, optical flows were determined from the view video. Based on these results, the overlapping video was made, in which the building structure was incorporated into the actual view. Furthermore, the proposed technique of moving picture overlapping was applied to the view simulation of transmission line tower. Consequently, it was demonstrated that the overlapped moving pictures can provide information which can not be obtained from the still pictures. It was ...

1994-11-01

221

Study of building materials impregnation processes by quasi-real-time neutron radiography  

International Nuclear Information System (INIS)

Neutron radiography (NR) is a useful non-destructive method for determination of hydrogen content in various building and technical materials. Monitoring of transport processes of moisture and hydrogenous liquids in porous building materials is enabled by fast, quasi-real-time NR methods based on novel imaging plate neutron detectors (IP-NDs). Hydrogen content in the samples is determined by quantitative analysis of measured profiles of neutron attenuation in the samples. Detailed description of quantitative NR method is presented by the authors in another accompanying contribution at this conference. Deterioration of building materials is originated by different processes that all require presence of water therefore it is essential to limit or prevent the transport of water through the porous material. In this presentation, results of a study of clay brick impregnation by silicone based hydrophobic agents will be ...

1999-11-03

222

Solar energy in buildings; L'energie solaire dans le batiment  

Energy Technology Data Exchange (ETDEWEB)

This document gathers the presentations given at the first French national meetings of solar energy for the development of solar systems in buildings. The meeting was organized over two days. The first day comprises 4 workshops about: urbanism and planning, cultural acceptability of solar energy in buildings (the OPAC 38 housing association, point of view on an energy information point, the Freiburg (Germany) solar region and marketing examples), technical integration to the structure (Clipsol solutions), and economical criteria (compared impacts of R and D public photovoltaic programs (USA, Japan, Germany, France, Italy), financing of rehabilitation projects, global approach of solar photovoltaic energy, technical solutions and strategy of products development, why and how to make an economical analysis of solar energy applications in the building industry). The second day comprises a plenary session and a round table: ...

2003-07-01

223

Sequence space coverage, entropy of genomes and the potential to detect non-human DNA in human samples  

UK PubMed Central (United Kingdom)

BackgroundGenomes store information for building and maintaining organisms. Complete sequencing of many genomes provides the opportunity to study and compare global information properties...Full Text Available

224

Semiconductor Radiation Detectors with Frisch Collars and Collimators for Gamma Ray Spectroscopy and Imaging  

Energy Technology Data Exchange (ETDEWEB)

To study CdZnTe as a high energy resolution gamma ray detector with a novel new design, and to build a detector array from the new detector design

2006-12-04

225

Room climate - air quality - thermal comfort; Raumklima - Luftqualitaet - Behaglichkeit  

Energy Technology Data Exchange (ETDEWEB)

The article presents measures for the solution of construction-biological problems and for reducing the pollutant load of buildings. (HW) [Deutsch] Der Artikel berichtet ueber Massnahmen ueber Sanierung von baubiologischen Schwachstellen und Schadstoffbelastungen in Gebaeuden. (HW)

1995-12-31

226

Regulatory compliance | Mott MacDonald  

Wastenet

...broad range of experience in designing and building research and development laboratories for products such as vaccines, blood and sera, biological products, medical devices, solid dosage forms , highly potent products and cytotoxic material. We also have experience in a range of modular laboratories for TSE research, ...

227

Radiological aspects of the usability of red mud as building material additive  

International Nuclear Information System (INIS)

Several researchers have examined and achieved favourable results in connection with the building industry's use of red mud extracted in large quantities from the processing of bauxite. These days more and more precedence is being given to limiting the radiological dose to the population. In this study carried out in Hungary, the use of red mud, bauxite, and clay additives recommended for the production of special cements, were examined from a radiological aspect. "2"2"6Ra and "2"3"2Th activity concentrations measured in Hungarian bauxite, red mud and clay samples were significantly similar with the levels for such raw materials mentioned in international literature. Taking radiation protection aspects into consideration, none of these products can be directly used for building construction. Taking Hungarian and international values into consideration, a small amount of red mud, not exceeding 15% could be used for brick production, for example ...

2008-02-11

228

RCRA closure of the Building 3001 Storage Canal  

Energy Technology Data Exchange (ETDEWEB)

The 3001 Storage Canal is located under portions of Buildings 3001 and 3019 at Oak Ridge National Laboratory (ORNL) and has a capacity of approximately 62,000 gallons of water. The term canal has historically been used to identify this structure, however, the canal is an in-ground reinforced concrete structure satisfying the regulatory definition of a tank. From 1943 through 1963, the canal in Building 3001 was designed to be an integral part of the system for handling irradiated fuel from the Oak Ridge Graphite Reactor. Because one of the main initial purposes of the reactor was to produce plutonium for the chemical processing pilot plant in Building 3019, the canal was designed to be the connecting link between the reactor and the pilot plant. During the war years, natural uranium slugs were irradiated in the reactor and then pushed out of the graphite matrix into the system of diversion plates and chutes which directed ...

1992-09-01

229

Quantum computing with solids  

Energy Technology Data Exchange (ETDEWEB)

Science and technology could be revolutionized by quantum computers, but building them from solid-state devices will not be easy. Robert W Keyes of IBM's research division outlines the challenges in scaling up the technology from lab experiments to practical devices. (U.K.)

2002-08-01

230

QED processes on e"+e"#+-#-, ep-, #gamma##gamma#-colliders  

International Nuclear Information System (INIS)

The present status of theoretical description of deep-inelastic lepton-nucleon as well as large angle Bhabha scattering with account for radiative corrections in the leading and next-to-leading approximations are reviewed. Also considered is a build-up principle and physical programme of the photon-photon colliders

231

Protracted neurotoxicity from chlordane sprayed to kill termites.  

UK PubMed Central (United Kingdom)

Over 250 adults and children were exposed to chlordane when the wooden building surfaces and soil around an apartment complex were sprayed in 1987. Two hundred-sixteen adults had neurobehavioral functions...Full Text Available

1995-07-01

232

Probing the structural hierarchy and energy landscape of an RNA T-loop hairpin  

UK PubMed Central (United Kingdom)

The T-loop motif is an important recurrent RNA structural building block consisting of a U-turn sub-motif and a UA trans Watson–Crick/Hoogsteen base pair. In the presence of...Full Text Available

2007-11-01

233

Normandy Breakout: Strategic Decisions and Leadership Actions in Operations Goodwood and Cobra.  

Science.gov (United States)

Theoretically, the outcome of World War II in Europe hung in the balance as the Allies poured onto the Normandy beachhead. Following the June 6, 1944 invasion, the Allies continue to come ashore, massively building up men and material inside the beachhead...

2000-01-01

234

New library buildings. Part VII. The Health Sciences Library of the University of Virginia.  

UK PubMed Central (United Kingdom)

This article describes the new Health Sciences Library at the University of Virginia Medical Center in Charlottesville, Virginia. The library was under construction for about two years and opened in...Full Text Available

1976-07-01

235

Natural and hybrid ventilation in schoolhouses. Requirements on air quality and thermal conditions; Naturlig og hybrid ventilasjon i skolebygninger  

Energy Technology Data Exchange (ETDEWEB)

The indoor climate of school buildings have been much debated recently. Many problems connected with air quality and thermal comfort are caused by bad maintenance, fitted carpets and no sunshades. Mechanical ventilation in schools has gained a bad reputation and many municipalities are seeking other solutions when building new schools. Natural ventilation according to the ''Swedish model'' does not use air filters or heat recovery from the outgoing air and achieve low energy consumption by reducing the airflow substantially in cold weather. Most of the naturally ventilated schools have supply air culverts of concrete below ground outside the building and in the basement. This is also true of schools using hybrid ventilation, where natural and mechanical ventilation is combined. The naturally ventilated schools often use manual control of the ventilation, which may not always be a good ...

2000-07-01

236

NIK Stabilization in Osteoclasts Results in Osteoporosis and Enhanced Inflammatory Osteolysis  

UK PubMed Central (United Kingdom)

BackgroundMaintenance of healthy bone requires the balanced activities of osteoclasts (OCs), which resorb bone, and osteoblasts, which build bone. Disproportionate action of OCs...Full Text Available

237

Mine dumps as a source of radon impact on buildings  

Energy Technology Data Exchange (ETDEWEB)

More than 100 old mine dumps active mine tailing ponds and granite quarries were investigated in South-West Germany to evaluate their potential impact on the environment caused by natural radioactive materials and by toxic metals. Five mine sites were monitored for a longer period according to their radon impact on the environment. They showed seasonal variations greater than a factor of 5 at some places. The annual mean radon concentration over granitic soil was found to be about 44 Bq.m/sup -3/ while very near the dumps more than 370 Bq.m/sup -3/ were usual. Radium concentrations up to 185 Bq.kg/sup -1/ were found in certain types of abandoned mine dumps. Some of the waste rock piles investigated are in the immediate neighbourhood of buildings and some old mine establishments are now used as homes. In these dwellings passive time integrating radon dosemeters have been exposed for up to a three month period. The average radon concentrations in the ...

1984-01-01

238

Microfungal contamination of damp buildings--examples of risk constructions and risk materials.  

UK PubMed Central (United Kingdom)

To elucidate problems with microfungal infestation in indoor environments, a multidisciplinary collaborative pilot study, supported by a grant from the Danish Ministry of Housing and Urban Affairs,...Full Text Available

1999-06-01

239

Joint Research Centre - JRC - European Commission  

Wastenet

... The high resolution imagery , collected over Rio de Janeiro, Brazil, included a mixture of large commercial buildings and private houses, as well as the airport and some community parks. 10/08/11 Read more Top EU R&D companies expect a 5% ...

240

Investigating radon transport through different saudi building materials  

International Nuclear Information System (INIS)

Radon has been recognized by various international health organizations as a major lung carcinogen. The onset of cellular carcinogenesis involves DNA damage to bronchi epithelial cells by particles emitted by radon progeny. Radon diffusion is an important release mechanism for radon that is produced inside a building material. The physical parameter that characterizes this process is the radon diffusion Coefficient D(m-2 s-l). The diffusion constant and Diffusion length has been measured as 2.15xl0- 6 m-2s-1, 1.01m for soil, 1.65x10-6m-2s-1, 0.89m for sand and 0.21x 10-6m-2s-1, 0.31m for crush aggregate saudi building materials respectively. The values are found to be minimum for crush aggregates, which shows that crush aggregate is least permeable to radon flow as compared with the other building materials studied. (author)

2007-06-01

241

Hypothesis for induction and propagation of chemical sensitivity based on biopsy studies.  

UK PubMed Central (United Kingdom)

The reactive airways dysfunction syndrome (RADS), the reactive upper airways dysfunction syndrome (RUDS), the sick building syndrome (SBS), and the multiple chemical sensitivity syndrome (MCS) are overlapping...Full Text Available

1997-03-01

242

Hybrid Gas/Electric Vehicle.  

Science.gov (United States)

The purpose of this project was to build a long-range, parallel hybrid gas/electric vehicle capable of driving beyond the communter capabilities of series hybrid vehicles. It was envisioned that since the gas engine would be able to independently propel t...

1985-01-01

243

Hawaii Clean Energy Initiative Existing Building Energy Efficiency Analysis: November 17, 2009 - June 30, 2010  

Energy Technology Data Exchange (ETDEWEB)

In June 2009, the State of Hawaii enacted an Energy Efficiency Portfolio Standard (EEPS) with a target of 4,300 gigawatt hours (GWh) by 2030 (Hawaii 2009). Upon setting this goal, the Hawaii Clean Energy Initiative, Booz Allen Hamilton (BAH), and the National Renewable Energy Laboratory (NREL), working with select local stakeholders, partnered to execute the first key step toward attaining the EEPS goal: the creation of a high-resolution roadmap outlining key areas of potential electricity savings. This roadmap was divided into two core elements: savings from new construction and savings from existing buildings. BAH focused primarily on the existing building analysis, while NREL focused on new construction forecasting. This report presents the results of the Booz Allen Hamilton study on the existing building stock of Hawaii, along with conclusions on the key drivers of potential energy efficiency savings and on the steps ...

2010-06-01

244

Gene-Environment Interactions in Schizophrenia: Review of Epidemiological Findings and Future Directions  

UK PubMed Central (United Kingdom)

Concern is building about high rates of schizophrenia in large cities, and among immigrants, cannabis users, and traumatized individuals, some of which likely reflects the causal influence of environmental...Full Text Available

2008-11-01

245

Functionalized Vegetable Oils for Utilization as Polymer Building Blocks: Office of Industrial Technologies (OIT) Agriculture Project Fact Sheet  

Energy Technology Data Exchange (ETDEWEB)

Vegetable oils such as soybean oil will be converted to novel polymers using hydroformylation and other catalytic processes. These polymers can be used in the construction, automotive, packaging, and electronic sectors.

2001-09-12

246

First Evidence of Division and Accumulation of Viable but Nonculturable Pseudomonas fluorescens Cells on Surfaces Subjected to Conditions Encountered at Meat Processing Premises?  

UK PubMed Central (United Kingdom)

Cleaning and disinfection of open surfaces in food industry premises leave some microorganisms behind; these microorganisms build up a resident flora on the surfaces. Our goal was to explore the phenomena...Full Text Available

2007-05-01

247

Face or building superiority in peripheral vision reversed by task requirements  

UK PubMed Central (United Kingdom)

Peripheral vision has been the topic of few studies compared with central vision. Nevertheless, given that visual information covers all the visual field and that relevant information can...Full Text Available

248

Evidence of an inflammatory-like response in non-normally pigmented tissues of two scleractinian corals  

UK PubMed Central (United Kingdom)

Increasing evidence of links between climate change, anthropogenic stress and coral disease underscores the importance of understanding the mechanisms by which reef-building corals resist infection...Full Text Available

2008-12-07

249

Energy Engineering Analysis Program Limited Energy Study, Fort Hunter-Liggett, California. Volume 1  

Science.gov (United States)

The purpose of this study is to develop projects and actions that will reduce facilities energy consumption and operating costs at Fort Hunter Liggett. Implementation of these projects will contribute to achieving the goal of the Army Facilities Energy Plan of a reduction in energy consumption per square foot of building floor area of 20 percent by FY2OOO from FY1985 baseline levels, There are 205 numbered structures at Fort Hunter Liggett, containing a total of 791,034 square feet of gross floor space. This United Energy Study evaluates 52 surveyed buildings with results extended to an additional 44 identical or similar buildings. Together, these buildings contain a total of 632,386 gross square feet and account for approximately 93 percent of overall energy usage. Present Energy Consumption Total energy consumption at Fort Hunter Ligett in FY 1992 of non-transportation energy sources was 79,728 ...

1993-12-31

250

Emotions run high in race for collider  

CERN Multimedia

The head of KEK expressed his dismay that SLAC has entered into a collaboration with 3 other US labs and proposes to build the next linear collider at Fermilab, Ilinois. KEK wants the next accelerator to be built somewhere in the Asian Pacific region (1 page).

2001-01-01

251

Elevated temperature mechanical properties of fire resistant steel for building structural use. Kenchiku kozoyo taika kozai no koon kyodo tokusei  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the test results on high-temperature strength properties of fire resistant steel(FR steel) for building, the formulation, and the examples of application to member tests and actual buildings. Because of its components and manufacturing method, FR steel excels in strength at elevated temperature due to precipitation and dispersion strengthening. Tests on high temperature properties of FR steel showed that every property such as strength, stress-strain curve, elastic modulus, and creep performance at high temperature was superior to those of conventional steels. Then, it was confirmed in the tensile tests at room temperature and high temperature after heat history that FR steel could be reused after fire. It was also found in the member tests that columns and beams of FR steel could support loadings equivalent to long-term allowable unit stress until the temperature rose up to 600 centigrade. Moreover, test results could be ...

1991-09-30

252

Elasto-plastic analysis of settlement of pile foundations. Part 2. ; Prediction of immediate settlement of building. Kui kiso no dansosei chinka kaiseki. 2. ; Kenchikubutsu no sokuji chinka yosoku hoho  

Energy Technology Data Exchange (ETDEWEB)

When the foundations of the building are designed and worked, the prediction calculation of immediate settlement of the building exercised practically is to calculate assuming the earth is a linear elastic body, but the actual stress-strain relationship of the earth is nonlinear and rigidity of the earth becomes lower as strain (or stress) increases. Hence in order to grasp the actual settling behavior of the earth, it is necessary to elucidate the nonlinear relationship between stress and strain. In this article, a prediction method of building settlement is introduced which uses an analytical technique of the multi-layered earth by the linear elasticity theory and takes into consideration strain dependency of rigidity of the earth. Part of the conclusion is as follows which has been obtained by studying the settling behaviors observed in examples of vertical loading tests of the pile foundations and the elasto-plastic ...

1992-12-25

253

Design and Implementation of an Open Source Indexing Solution for a Large Set of Radiological Reports and Images  

UK PubMed Central (United Kingdom)

This paper hopes to share the insights we experienced during designing, building, and running an indexing solution for a large set of radiological reports and images in a production environment for...Full Text Available

2007-11-01

254

Computer codes for the determination of air flow in buildings; Rechenprogramme zur Bestimmung der Luftstroemungen in Gebaeuden  

Energy Technology Data Exchange (ETDEWEB)

The report provides and overview of calculation models for the simulation of airflows and deals comprehensively with field and multi-zone models as well as the coupling of individual zone and multi-zone models. Examples of calculations are given. figs., tabs., refs.

1994-12-31

255

Complete programming documentation for ECIP expansion of existing Energy Monitoring and Control System (EMCS), Fort Leonard Wood, Missouri  

Science.gov (United States)

The objective of this project is to reduce energy consumption in 203 buildings by providing a new EMCS (Energy Monitoring Control System) to control and monitor systems.

1993-12-01

256

Comparison of Indoor Mercury Vapor in Common Areas of Residential Buildings with Outdoor Levels in a Community Where Mercury Is Used for Cultural Purposes  

UK PubMed Central (United Kingdom)

Elemental mercury has been imbued with magical properties for millennia, and various cultures use elemental mercury in a variety of superstitious and cultural practices, raising health concerns for...Full Text Available

2006-01-01

257

Chromosomal study in lymphocytes from subjects living or working in buildings constructed with radioactively contaminated rebar  

Energy Technology Data Exchange (ETDEWEB)

It has recently been found that many buildings in Taiwan were constructed with radioactively contaminated rebar, which raised great concern among the residents as well as governmental officials. In order to investigate the possible cytogenetic damage to the residents of contaminated buildings, a G-banding method was carried out on the lymphocytes of 30 radiation-exposed individuals from four families and one office building, as well as 15 control individuals from laboratory personnel. The estimated cumulative radiation doses for the exposed people range from 19.63 to 280.50 mSv. Altogether, 13 females and 17 males belonging to the radiation-exposed group, and 7 females and 8 males in the control group, were included in this study. With the exception of one sample, at least 500 metaphase spreads were scored and analyzed for each individual. All the recognizable structural aberrations of chromosomes or chromatids were ...

1997-07-03

258

Chromosomal study in lymphocytes from subjects living or working in buildings constructed with radioactively contaminated rebar  

International Nuclear Information System (INIS)

It has recently been found that many buildings in Taiwan were constructed with radioactively contaminated rebar, which raised great concern among the residents as well as governmental officials. In order to investigate the possible cytogenetic damage to the residents of contaminated buildings, a G-banding method was carried out on the lymphocytes of 30 radiation-exposed individuals from four families and one office building, as well as 15 control individuals from laboratory personnel. The estimated cumulative radiation doses for the exposed people range from 19.63 to 280.50 mSv. Altogether, 13 females and 17 males belonging to the radiation-exposed group, and 7 females and 8 males in the control group, were included in this study. With the exception of one sample, at least 500 metaphase spreads were scored and analyzed for each individual. All the recognizable structural aberrations of chromosomes or chromatids were ...

259

COST ESTIMATING TOOLS AND RESOURCES FOR ADDRESSING SITES UNDER THE BROWNFIELDS INITIATIVE  

Science.gov (United States)

Brownfields redevelopment contributes to the revitalization of communities across the U.S. Reuse of these abandoned, contaminated sites spurs economic growth, builds community pride, protects public health, and helps maintain our nation's "greenfields," often at a relatively low ...

260

Analysis of fatal motor vehicle collisions: evidence from Central Macedonia, Greece  

UK PubMed Central (United Kingdom)

Background: The objective of this study was to assess the factors associated with the traffic mortality in the region of Central Macedonia in order to produce evidence in building up preventive...Full Text Available

2011-01-01

261

An assessment and evaluation for recycle/reuse of contaminated process and metallurgical equipment at the DOE Rocky Flats Plant Site -- Building 865. Final report  

Energy Technology Data Exchange (ETDEWEB)

An economic analysis of the potential advantages of alternatives for recycling and reusing equipment now stored in Building 865 at the Rocky Flats Plant (RFP) in Colorado has been conducted. The inventory considered in this analysis consists primarily of metallurgical and process equipment used before January 1992, during development and production of nuclear weapons components at the site. The economic analysis consists of a thorough building inventory and cost comparisons for four equipment dispositions alternatives. The first is a baseline option of disposal at a Low Level Waste (LLW) landfill. The three alternatives investigated are metal recycling, reuse with the government sector, and release for unrestricted use. This report provides item-by-item estimates of value, disposal cost, and decontamination cost. The economic evaluation methods documented here, the simple cost comparisons presented, and the data provided as a supplement, should ...

1993-08-01

262

A model for the single stranded random coil form of polydeoxyadenylic acid from minimum energy conformations of the dimeric subunit.  

UK PubMed Central (United Kingdom)

The minimum energy conformations of dApdA have been examined for their suitability as buildings blocks of the single stranded coil form of polynucleotides. Calculations of the characteristic ratio C...Full Text Available

1978-09-01

263

8. Application of radionuclide X-ray fluorescence analysis in other fields of science and technology  

International Nuclear Information System (INIS)

Certain applications are described of radionuclide X-ray fluorescence analysis in the ore dressing industry, in the manufacture of building materials, in metallurgy, pharmacy, in the chemical, photographic and paper industries, in space exploration, in archeology and for measuring the thicknesses of thin layers of coatings. (ES).

1983-12-01

264

27na4  

Wastenet

by American scientists, ecosystems containing a greater number of plant species, produce more biomass.This result ...to meet the increasing demand for land for farmland planted with monocultures, buildings and roads.For ...have hypothesized that greater ecological diversity (diversity of plant and animal species) leads to a greater

265

Utilization of wastes from coal-fired power plants for soil improvement and plant nutrition  

International Nuclear Information System (INIS)

The reduction of emission from power plants of the public power industry inevitably leads to more and more residual products being obtained which require utilization. Traditionally, the building and building materials industry as well as, for a number of years, the gypsum industry have been the main customers processing these residual materials. To avoid having to tip them at landfills that are in short supply already, further uses are sought; so, for instance, in farming to ameliorate soil and fertilize plants. Relative to this subject, proposals are already available which are presented as lectures at the conference and discussed, together with practical knowledge and new investigation results. (BBR).

1991-10-08

266

Telephone exchange Feutersoey - first pilot plant of the PTT with solar collectors  

Energy Technology Data Exchange (ETDEWEB)

In the course of this year six local exchange offices with alternative heating and hot water plants were started up in Switzerland. They are all of the same building type, designed for not more than 1000 telephone subscribers and for the same architectural conditions. However, the buildings are situated in different areas of the country and are thus subject to different environmental conditions. Solar collectors supplemented by electricity boilers are fitted to two of these objects. Heat pumps are operated in two other exchange offices while the last two are equipped with electric heating devices. For purposes of comparison two new test plants of the same size with oil heating devices are set up.

1981-01-01

267

Study on reactor building structures using ultrahigh strength materials - Part 8: Results of mixed structure tests  

International Nuclear Information System (INIS)

The mixed structure of a nuclear reactor building is composed of SC-columns, S-beams, S-joints and PCa-panels. Following the last report (Part 7)[1], the main test results of the mixed structure, that is, the deformation mode, strain distribution and shear strength, are described. The S-joints using ultrahigh strength materials had no buckling nor shear slipping. The proposed mixed structure resisted the external horizontal forces under integrated uniformity among SC-columns, S-joints and PCa-panels. It could be confirmed that the mixed structure can be established. (author)

1993-08-15

268

Study on reactor building structure using ultrahigh strength materials - Part 7: Outline of mixed structure tests  

International Nuclear Information System (INIS)

The objective of this study is to comprehend the basic structural characteristics of box shaped mixed structures proposed for a future nuclear reactor building structure. Specimens of reinforced concrete precast panel walls of the mixed structures were prepared using ultrahigh strength materials. Two bending shear tests were conducted with a parameter of the quantity of reinforcement bars. The results include: (1) Relationship of shear stress and the angle of the structure, and (2) Failure mode. (author)

1993-08-15

269

Review of Cardiff telephone exchange total energy system after three years operation  

Energy Technology Data Exchange (ETDEWEB)

A self contained continuous power generation system as described at INTELEC 1979, was successfully commissioned and put into service in a major communications centre at Cardiff in Wales. The objective was to provide all telecommunications equipment and electrical building engineering services from a dual fuel enginegenerating plant, and to recover waste heat energy to heat or cool the building. The plant, which is fully automatic, comprises five 1300kW engines using natural gas or diesel oil, and associated waste heat boiler and chiller systems. This paper reviews the functioning of the plant during its first three years of operation.

1983-10-01

270

Report on Challenges and Resolutions for the Purple Development Environment  

Energy Technology Data Exchange (ETDEWEB)

Previous AIX development environment experience with ASC White and Early Delivery systems UV and UM was leveraged to provide a smooth and robust transition to the Purple development environment. Still, there were three major changes that initially caused serious problems for Purple users. The first was making 64-bit builds of executables the default instead of 32-bit. The second was requiring all executables to use large page memory. The third was the phase-out of the popular, but now defunct, third-party C++ compiler KCC, which required the migration of many codes to IBM's xlC C++ compiler. On Purple, the default build environment changed from 32-bit builds to 64-bit builds in order to enable executables to use the 4GB per processor (32GB per node) memory available, and in order for the MPI library to do collective optimizations that required the larger 64-bit address space. The 64-bit ...

2006-12-12

271

Renovation of air-conditioning at La Defense; Renovation de la climatisation a La Defense  

Energy Technology Data Exchange (ETDEWEB)

Twenty years after its building, the tertiary sector of La Defense district near Paris has been rehabilitated. The main reason is not only the age and wear of materials but the heating costs, the fire protection regulations, the search for a better air quality and air renewing with less dusts, smells and noise and a controlled moisture. This paper describes first the original installation of the Monge CB 6 office building and then the renovated installation: the central hot and cold air-treatment plant, the variable flow ventilation system, the air extraction and supply system threw the roofs and the pressure and thermal regulation of the installation. (J.S.)

1997-05-01

272

Radiation control aspects of the civil construction for a high power free electron laser (FEL) facility  

International Nuclear Information System (INIS)

The paper discusses some of the assumptions and methods employed for the control of ionizing radiation in the specifications for the civil construction of a planned free electron laser facility based on a 200 MeV, 5 mA superconducting recirculation electron accelerator. Consideration is given firstly to the way in which the underlying building configuration and siting aspects were optimized on the basis of the early assumptions of beam loss and radiation goals. The various design requirements for radiation protection are then considered, and how they were folded into an aesthetically pleasing and functional building. copyright 1997 American Institute of Physics.

1996-11-06

273

Prediction of motions and tension in mooring lines on slack-moored floating oceanic architectural building in coastal zones  

Energy Technology Data Exchange (ETDEWEB)

The present paper is concerned with the prediction method for the motions and tensions of mooring lines on slack-moored floating oceanic architectural building in coastal zone. The motions and the tensions of mooring lines were estimated by the time domain numerical simulation in the present method. The present method includes the nonlinearity of mooring system, slow varying wave drift force. The authors performed a time domain numerical simulation for motions and the tensions of mooring lines on floating barge in two component waves. Also, the results obtained by numerical simulation were compared with the experimental results. The validity of the present method was confirmed.

1995-12-31

274

Method for the reduction of radioactivity of some building materials  

International Nuclear Information System (INIS)

A few industry-derived and conventional building materials have above acceptable radioactivity. An examination of some materials presently used, or with a potential for use, has shown that in phosphogypsum, fly ash, zircon kyanite tailings, red mud and brickmaking clay, the radium equivalent activities of the finer fractions (<53 #mu#) are higher than those of the larger fractions. Consequently, the radioactivity of these materials could be reduced by dry-sieving and discarding the fines. In blast furnace slag and dissociated zircon, no such reduction would occur since the radioactivity is evenly distributed in all sized fractions.

275

Heating-cooling ceilings and cold beams; Plafonds chauffants-rafraichissants et poutres froides  

Energy Technology Data Exchange (ETDEWEB)

The aim of this document is to make a state-of-the-art of the techniques of heating-cooling ceilings and cold beams. These systems offer many advantages: they generate a high quality thermal comfort, they are energy efficient, and offer important room saving, particularly interesting in the case of building renovation. The document comprises 5 parts dealing with: 1 - the heating-cooling ceilings; 2 - the cold beams; 3 - the elements necessary for the dimensioning (building-system interactions, ventilation, temperature regulation and safety systems); 4 - dimensioning method; 5 - design, realization and operation: the rules to follow. (J.S.)

2004-07-01

276

Gold and gold-silver core-shell nanoparticle constructs with defined size based on DNA hybridization  

Energy Technology Data Exchange (ETDEWEB)

Nanoparticles represent versatile building blocks in material science and nanotechnology. Thereby, the defined assembly of nanostructures (13 and 56 nm in diameter, respectively) is of significant importance. Short DNA sequences can be bound to the nanoparticle surface thus enabling highly specific DNA hybridization-driven events that direct the formation of nanoparticle constructs.In this paper, examples for the defined formation of gold nanoparticle constructs are demonstrated. In addition, gold-silver core-shell nanoparticles are introduced as further building blocks for the hybridization-controlled formation of nanoparticle constructs.

2009-04-15

277

Geothermal heat pump applications: Industrial/commercial  

Energy Technology Data Exchange (ETDEWEB)

The fastest rate of growth in the space conditioning market has been attributed to the application of geothermal heat pumps to the industrial and commercial markets. The author reviews and provides examples of the three most popular components of a large geothermal heat pump system: geothermal earth coupling, heat pumps and heat exchangers, and building side terminals. These components are applied to three example geothermal installations: a library, an office building, and a school. Examples of energy use before and after the installation of a geothermal space conditioning system are summarized. General design and cost guidelines and comments on the use of geothermal heat pump in these and similar applications are discussed.

1999-07-01

278

GT13E gas turbines to power Killingholme A GTCC [gas turbine combined-cycle] plant  

Energy Technology Data Exchange (ETDEWEB)

National Power is building its first gas turbine combined cycle power station at Killingholme, situated to the south of the River Humber in the East of England. NEI ABB Gas Turbines Limited was awarded the turnkey contract in July 1990 to build a nominal 650 MW combined cycle power station based around three Asea Brown Boveri GT13E gas turbines. The project is outlined in this article. The plant is due for completion in July 1993. (author)

1993-01-01

279

Evaluation of tritiated water retention capacity of fusion reactor concrete building  

Energy Technology Data Exchange (ETDEWEB)

In this paper the diffusion of tritiated water vapor into concrete walls is studied to evaluate tritiated water retention capacity of a fusion reactor concrete building. Using a model of the tritiated water diffusion determined form experimental results, depth profiles of tritiated water in concrete are calculated in the case of being exposed to air containing tritiated water vapor during the normal operational condition of a fusion reactor. A 0.5-m-thick concrete is sufficient for reactor hall walls from a viewpoint of the tritium containment.

1992-03-01

280

Evaluation of tritiated water retention capacity of fusion reactor concrete building  

International Nuclear Information System (INIS)

In this paper the diffusion of tritiated water vapor into concrete walls is studied to evaluate tritiated water retention capacity of a fusion reactor concrete building. Using a model of the tritiated water diffusion determined form experimental results, depth profiles of tritiated water in concrete are calculated in the case of being exposed to air containing tritiated water vapor during the normal operational condition of a fusion reactor. A 0.5-m-thick concrete is sufficient for reactor hall walls from a viewpoint of the tritium containment.

281

Evaluation of the residual radiation field in the proton accelerator facility of the Proton Engineering Frontier Project (PEFP) in Korea  

British Library Electronic Table of Contents (United Kingdom)

In Korea, the Proton Engineering Frontier Project (PEFP) is building a proton linear accelerator facility with energy up to 100MeV and a beam current of 20mA. In this study, a radiation field after shutdown in the accelerator facility of the PEFP was evaluated for the purpose of the radiation shielding by using MCNPX code. A facility modeling was performed for the accelerator tunnel building, accelerator chain, target rooms and beam experiment hall. And radiation source terms were evaluated in the facility. With this facility, model and radiation source terms, the concentration of 41Ar was evaluated and the cooling time satisfying regulation in Korea was calculated.

2007-01-01

282

Energy-Smart Building Choices: How School Facilities Managers and Business Officials Are Reducing Operating Costs and Saving Money  

Science.gov (United States)

Most K-12 schools could save 25% of their energy costs by being smart about energy. Nationwide, the savings potential is $6 billion. While improving energy use in buildings and busses, schools are likely to create better places for teaching and learning, with better lighting, temperature control, acoustics, and air quality. This brochure, targeted to school facilities managers and business officials, describes how schools can become more energy efficient.

2001-08-06

283

Energy nomographs as a design tool for daylighting  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this paper is to inform commercial building designers about an energy analysis tool which can aid them in making appropriate decisions about daylighting. The energy nomographs are an energy design tool which calculate the annual energy consumption of commercial buildings, including lighting, heating, cooling, domestic hot water, fans, pumps, and miscellaneous items. This paper specifically discusses the daylighting aspects of the tool. The calculation procedure is presented with an example to explain how this design tool can be used to make good energy decisions early in the design process.

1984-01-01

284

Energy conservation by means of integrated systems; Beter resultaat door klimaatkwartet  

Energy Technology Data Exchange (ETDEWEB)

Air conditioning is getting maximum attention these days when building new offices. For the new office building of the assurance company Zwitserleven in Amstelveen, Netherlands, a new air conditioning concept is applied, based on four existing air conditioning methods: cold storage and heat storage in the soil, heat pump, double-wall facades with integrated climate control, and radiant heating combined with a cooling system in the ceiling. The integration of these methods not only provides complete climate comfort for the employees but also substantial energy savings. 3 figs.,1 ills.

1995-11-01

285

Decontamination of building surface using clay suspension  

Energy Technology Data Exchange (ETDEWEB)

The decontamination of the urban building surfaces, based on the covering of clay suspensions, has been studied. Contaminated samples for test purpose were prepared by application of radioactive solution which was extracted from the soil of 2 km zone of the Chernobyl Nuclear Power Plant(ChNPP). The cation converting conditions of clay suspensions were determined by the experiments of swelling and stability of the suspensions. According to the experimental results, the most effective clay suspension was the NH{sub 4}-type which had a 7.1 of decontamination factor(DF) on Cs and 4.5 of DF on total nuclides after 3 times covering on slate.

1994-07-01

286

Comparing Computer Run Time of Building Simulation Programs  

Energy Technology Data Exchange (ETDEWEB)

This paper presents an approach to comparing computer run time of building simulation programs. The computing run time of a simulation program depends on several key factors, including the calculation algorithm and modeling capabilities of the program, the run period, the simulation time step, the complexity of the energy models, the run control settings, and the software and hardware configurations of the computer that is used to make the simulation runs. To demonstrate the approach, simulation runs are performed for several representative DOE-2.1E and EnergyPlus energy models. The computer run time of these energy models are then compared and analyzed.

2008-07-23

287

Beginning Scala  

CERN Document Server

The open source Scala language is a Java--based dynamic scripting, functional programming language. Moreover, this highly scalable scripting language lends itself well to building Cloud--based/deliverable Software as a Service (SaaS) online applications. Written by Lift Scala web framework founder and lead Dave Pollak, Beginning Scala takes a down--to--earth approach to teaching Scala that leads you through simple examples that can be combined to build complex, scalable systems and applications. This book introduces you to the Scala programming language and then guides you through Scala constr

2009-01-01

288

Advances in Old-Fashioned Heterotic String Model Building  

CERN Document Server

I review findings of various research groups regarding perturbative heterotic string model building in the last 12 months. Attention is given to recent studies of extra U(1)'s and local discrete symmetries (LDS's) in generic string models. Issues covered include the role of U(1)'s and LDS's in limiting proton decay, developments in classification of models containing anomalous U(1), and possible complications resulting from kinetic mixing between observable and hidden sector U(1)'s. Additionally, recent string-derived and string-inspired models are briefly reviewed. Talk Presented at SUSY '97.

1998-01-01

289

Laboratory test on soil-structure interaction with backfill soil using non-linear material (embedment effect tests on soil-structure interaction)  

International Nuclear Information System (INIS)

A series of Model Tests of Embedment Effect on Reactor Buildings has been carried out by the Nuclear Power Engineering Corporation (NUPEC), under the sponsorship of the Ministry of International Trade and Industry (MITI) of Japan. Seismic response of an embedded reactor building is greatly affected by the non-linearity of the backfill soil. However, quite few experimental data have been obtained so far. The objective of this study is to qualitatively evaluate the non-linear behavior of the backfill soil through shaking table tests. Its effects to the seismic response of a reactor building constructed at a soft rock site can be made clear through the tests. Non-linear effects of the backfill soil on the seismic response of the embedded reactor building model were evaluated experimentally. Based on the sinusoidal and seismic wave excitation tests, the following conclusions were obtained regarding the ...

1993-08-15

290

Hawaii demand-side management resource assessment. Final report: DSM opportunity report  

Energy Technology Data Exchange (ETDEWEB)

The Hawaii Demand-Side Management Resource Assessment was the fourth of seven projects in the Hawaii Energy Strategy (HES) program. HES was designed by the Department of Business, Economic Development, and Tourism (DBEDT) to produce an integrated energy strategy for the State of Hawaii. The purpose of Project 4 was to develop a comprehensive assessment of Hawaii`s demand-side management (DSM) resources. To meet this objective, the project was divided into two phases. The first phase included development of a DSM technology database and the identification of Hawaii commercial building characteristics through on-site audits. These Phase 1 products were then used in Phase 2 to identify expected energy impacts from DSM measures in typical residential and commercial buildings in Hawaii. The building energy simulation model DOE-2.1E was utilized to identify the DSM energy impacts. More detailed information on the typical ...

1995-08-01

291

Gas fired heaters and ventilation system improve indoor air quality and thermal comfort  

Energy Technology Data Exchange (ETDEWEB)

Rotex Inc. has designed and manufactured industrial sifting equipment since 1844. This site (an existing industrial facility) encompasses approximately 140,000 ft[sup 2] (13,006 m[sup 2]) of offices, R D shops, assembly and storage areas, as well as a large welding shop that was the main focus of this project. This facility consists of three separate buildings that are all connected and open to one another. The original building dates from 1908. The newest addition (32,400 ft[sup 2]; 3,010 m[sup 2]) was added in 1977, and is referred to as the 77 Building. This building was initially equipped with oil fired heating equipment due to the moratorium on new gas sales that was in effect at that time. This project was driven by the client's need to remove underground oil storage tanks to comply with environmental standards. This article describes the 77 Building conversion from ...

1994-03-01

292

Streamlined Approach for Environmental Restoration (SAFER) Plan for Corrective Action Unit 118: Area 27 Super Kukla Facility, Nevada Test Site, Nevada, Rev. No.: 1  

Energy Technology Data Exchange (ETDEWEB)

This Streamlined Approach for Environmental Restoration (SAFER) plan addresses closure for Corrective Action Unit (CAU) 118, Area 27 Super Kukla Facility, identified in the ''Federal Facility Agreement and Consent Order''. Corrective Action Unit 118 consists of one Corrective Action Site (CAS), 27-41-01, located in Area 27 of the Nevada Test Site. Corrective Action Site 27-41-01 consists of the following four structures: (1) Building 5400A, Reactor High Bay; (2) Building 5400, Reactor Building and access tunnel; (3) Building 5410, Mechanical Building; and (4) Wooden Shed, a.k.a. ''Brock House''. This plan provides the methodology for field activities needed to gather the necessary information for closing the CAS. There is sufficient information and process knowledge from historical documentation and site ...

2006-09-01

293

Memento of decision makers: the national organizations involved in the mastery of greenhouse gas emissions; Memento des decideurs: les collectivites territoriales engagees dans la maitrise des emissions de gaz a effet de serre  

Energy Technology Data Exchange (ETDEWEB)

In front of the risks linked with the increase of the greenhouse gas emissions in the atmosphere, the decision makers must take into consideration first, the scientific advice of climatic change experts, and second, the considerable inertia of the climatic system. Thus, any action implemented so far will have an impact all along the 21. century and later whatever the future human activities. The aim of this memento is to sensibilize the decision makers about the possible consequences of their choice in terms of volume of greenhouse gases and of medium- and long-term evolution: 1 - stakes, role of local decision-makers (greenhouse effect and climatic change, France's international commitment, stakes, liabilities of local decision makers, decentralization laws, local plans of fight against greenhouse effect, public information and dialogue); 2 - urbanism and transports (urban displacements, alternatives to individual cars, collective transportation systems, parking, inter-region ...

2003-07-01

294

Large scale rooftop photovoltaics grid connected system at Charoenphol-Rama I green building  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a technical feasibility study project for the large scale rooftop photovoltaics (PV) grid connected system at Charoenphol-Rama I green building super store of TESCO LOTUS (TL) in Thailand. The objective of this project is (i) to study the technical feasibility of installation 350 kWp PV systems on the top of the roof in this site (ii) and to determine the energy produce from this system. The technical factors are examined using a computerized PVS 2000 simulation and assessment tool. This super store building located in Bangkok, with latitude 14 N, longitude 100 E and the building direction is 16 from North direction. The building roof area is 14,000 m2; with 3 degree face East and 3 degree face West pitch. Average daily solar energy in this area is approximately 5.0 kWh. The study team for this project consists of educational institution as School of Renewable Energy Technology ...

2004-07-01

295

LEED - The green building rating system; Gruen ist nicht gleich Gruen - Einblicke in das LEED-Zertifizierungssystem  

Energy Technology Data Exchange (ETDEWEB)

Buildings in the USA are commonly not perceived as energy efficient and sustainable. Considering this, it comes as a surprise that the LEED (Leadership in Energy and Environmental Design) certification system is leading the process to certify ''Green Buildings'' despite the broad range of certification systems in countries such as BREEAM in England, CASBEE in Japan, HQE in France, Green Star in Australia, and most recently DGNB in Germany. International companies are pursuing the LEED certification due to its worldwide applicability - over 20,000 buildings in 76 countries are currently registered. (Abstract Copyright [2009], Wiley Periodicals, Inc.) [German] Die USA sind nicht gerade fuer oekologisches und energieeffizientes Bauen bekannt. Umso erstaunlicher ist es, dass das LEED-Zertifizierungssystem (Leadership in Energy and Environmental Design) neben anderen landesspezifischen ...

2009-04-15

296

Exposure to radiation from the natural radioactivity in building materials  

International Nuclear Information System (INIS)

Radiation exposure of members of the public can be increased appreciably by the use of building materials containing above-normal levels of natural radioactivity. This phenomenon has attracted attention in recent years, and in this review, an attempt is made to the quantify exposures incurred under various circumstances. The second section of the review is a general survey of those building materials, mostly industrial wastes, that have aroused interest in Member countries. The probability that environmental pressures may cause such wastes to be used more and more by building industries may lead to similar situations in the future. Other review material of a relevant nature is described in the third section. Primordial radionuclides only are considered here. They are: potassium-40 (K-40); radium-226 (Ra-226) and its decay products; the series headed by thorium-232 (Th-232). The important radiological consequences of the ...

2010-05-01

297

Comparative assessment of environmental performance tools and the role of the Green Building Challenge  

Energy Technology Data Exchange (ETDEWEB)

Green Building Challenge (GBC) was intended to advance the state-of-the-art of building performance assessment, through the development, testing, and discussion of an assessment framework, criteria and tool. The contributions of GBC to building performance assessment are considered through comparing similarities and differences with a selection of available assessment tools. Unlike national or proprietary assessment systems, GBC was not designed for application to specific commercial markets. Instead, it emphasized research and involved researchers and practitioners from many countries. Consequently, GBC has been in a unique position to test and adopt new ideas and implement step changes. GBC's roles over the past five years have been to provide a reference framework, method and tools that can be used to develop new systems or improve existing systems; provide a forum for discussion among researchers and ...

2001-09-01

298

A concept for an advanced computer-based building envelope design tool  

Energy Technology Data Exchange (ETDEWEB)

A review of current daylighting design tools indicates that over 30 tools are now available, including nomographs, protractors, overlays, and programs for micro-, mini-, and mainframe computers. Computer-based tools allow testing and analyzing of more design alternatives under a wider variety of conditions than was previously practical with slower techniques, but they have not fundamentally changed the information available to the design professional. These tools are applicable to certain limited functions of the design process and do not address the varying information needs of the designer at various points in the design process. We describe a concept for a computer-based building envelope design tool that is structured to overcome many of the limitations of the existing tools. The tool would address daylighting design in the context of the overall building envelope design, covering a range of environmental quality issues in addition to ...

1986-11-01

299

Use of solar assisted geothermal heat pump and small wind turbine systems for heating agricultural and residential buildings  

Energy Technology Data Exchange (ETDEWEB)

The main objective of the present study is twofold: (i) to analyze thermal loads of the geothermally and passively heated solar greenhouses; and (ii) to investigate wind energy utilization in greenhouse heating which is modeled as a hybrid solar assisted geothermal heat pump and a small wind turbine system which is separately installed in the Solar Energy Institute of Ege University, Izmir, Turkey. The study shows 3.13% of the total yearly electricity energy consumption of the modeled system (3568 kWh) or 12.53% of the total yearly electricity energy consumptions of secondary water pumping, brine pumping, and fan coil (892 kWh) can be met by using small wind turbine system (SWTS) theoretically. According to this result, modeled passive solar pre heating technique and combined with geothermal heat pump system (GHPS) and SWTS can be economically preferable to the conventional space heating/cooling systems used in agricultural and residential building heating ...

2010-01-15

300

Study on reactor building structure using ultrahigh strength materials - Part 9: Summary of the study  

International Nuclear Information System (INIS)

Considerations for longevity of nuclear facilities and ease of decommissioning are of great importance for future nuclear power plants. To this end, a concept of an optimal structural concept for nuclear reactor buildings has been studied: the main feature of this concept is to utilize large-sized, light weight prefabricated members with ultrahigh strength materials. The following two items have been selected to study the prospective structure: (1) Applicability of ultrahigh strength materials for reinforced concrete shear walls (2) Construction using large sized prefabricated members As the first step (1), material and structural tests using ultrahigh strength materials, and the subsequent analysis of those tests for reinforced concrete shear walls, has been conducted. The positive results of this study show a bright future for the use of ultrahigh strength materials for the reinforced concrete shear walls of nuclear reactor buildings. As the ...

1993-08-15

301

Storing hydroelectricity to meet peak-hour demand  

Energy Technology Data Exchange (ETDEWEB)

This paper reports on pumped storage plants which have become an effective way for some utility companies that derive power from hydroelectric facilities to economically store baseload energy during off-peak hours for use during peak hourly demands. According to the Electric Power Research Institute (EPRI) in Palo Alto, Calif., 36 of these plants provide approximately 20 gigawatts, or about 3 percent of U.S. generating capacity. During peak-demand periods, utilities are often stretched beyond their capacity to provide power and must therefore purchase it from neighboring utilities. Building new baseload power plants, typically nuclear or coal-fired facilities that run 24 hours per day seven days a week, is expensive, about $1500 per kilowatt, according to Robert Schainker, program manager for energy storage at the EPRI. Schainker the that building peaking plants at $400 per kilowatt, which run a few hours a day on gas or oil fuel, is less ...

1992-04-01

302

Storing hydroelectricity to meet peak-hour demand  

International Nuclear Information System (INIS)

This paper reports on pumped storage plants which have become an effective way for some utility companies that derive power from hydroelectric facilities to economically store baseload energy during off-peak hours for use during peak hourly demands. According to the Electric Power Research Institute (EPRI) in Palo Alto, Calif., 36 of these plants provide approximately 20 gigawatts, or about 3 percent of U.S. generating capacity. During peak-demand periods, utilities are often stretched beyond their capacity to provide power and must therefore purchase it from neighboring utilities. Building new baseload power plants, typically nuclear or coal-fired facilities that run 24 hours per day seven days a week, is expensive, about $1500 per kilowatt, according to Robert Schainker, program manager for energy storage at the EPRI. Schainker the that building peaking plants at $400 per kilowatt, which run a few hours a day on gas or oil fuel, is less ...

1992-01-01

303

Second aquifer storage under discussion. The power supply system of the German Bundestag building in Berlin; Zweiter Aquifer-Speicher im Gespraech. Zur Energieversorgung der Gebaeude des Deutschen Bundestages in Berlin  

Energy Technology Data Exchange (ETDEWEB)

The contribution outlines the current status of the building construction projects for the German Bundestag in Berlin. The following subjects are discussed: Energetic quality of the building, energy supply concept, integrated energy supply system, electric CHP systems, cogeneration (vegetable oil), aquifer storage (heat storage, cold storage), solar energy (photovoltaic energy conversion, thermal solar energy use), economic and ecological aspects. (HW) [Deutsch] Der vorliegende Beitrag gibt einen Ueberblick ueber den aktuellen Stand des Bauvorhabens des Deutschen Bundestages in Berlin. In diesem Zusammenhang wird auf folgende Themen eingegangen: Energetische Gebaeudequalitaet, Energieversorgungskonzept, Energieverbund, stromgefuehrte BHKWs, Kraft-Waerme-Kopplung (Pflanzenoel), Aquiferspeicher (Waermespeicher, Kaeltespeicher), Sonnenergienutzung (Photovoltaik, thermische Solarenergienutzung), Wirtschaftlichkeit und Oekologie. (HW)

1996-12-01

304

Renewable energy in the urban setting: Year two  

Energy Technology Data Exchange (ETDEWEB)

At the 1996 Conference in North Carolina, The Green Institute began to share its story. Their presentation this year will cover where they are in the design process and their plans for using solar and wind technologies in the development of an Eco-Industrial Park and Business Incubator. Located in a Federal Enterprise Community in Minneapolis, this project borrows sustainable and green building principles using the Rocky Mountain Institute and Solar Living Center as models. Using a change in the paradigm regarding how industry does business, The Green Institute is joining with developments across the country that are putting together Eco-Industrial Parks which use closed loop production systems to reduce waste and emissions generated from manufacturing processes. Using renewable energy, both solar and wind, presents challenges both in the integration of systems on this small site and the educational opportunities with a large potential audience outside the ...

1997-12-31

305

Reducing magnetic fields. Magnetic fields of high-voltage transmission lines or in residential buildings can be largely reduced; Magnetische Felder reduzieren. Bei Hochspannungsleitungen und in Wohnungen lassen sich magnetische Felder weitgehend kompensieren  

Energy Technology Data Exchange (ETDEWEB)

Magnetic fields can be compensated by opposing fields. This principle can be applied for reducing the magnetic fields emanating from high-voltage transmission lines or found in residential or commercial buildings. The article shows a number of concrete options for reducing magnetic fields in the vicinity of high-voltage lines through appropriate conductor configuration on the one hand, and a novel method using Helmholtz coils for compensating those fields in buildings. (orig.) [Deutsch] Magnetische Felder koennen durch Gegenfelder kompensiert werden. Dieses Prinzip laesst sich sowohl auf Hochspannungsleitungen als auch auf Wohn- und Arbeitsraeume uebertragen. Der Artikel zeigt konkrete Moeglichkeiten, wie einerseits Magnetfelder von Hochspannungsleitungen durch eine geeignete Konfiguration der Leiter reduziert werden koennen, und beschreibt andererseits eine neue Methode zur Reduktion solcher Felder in Wohn- und Arbeitsraeumen mittels ...

1997-10-17

306

Preliminary results from an advanced lighting controlstestbed  

Energy Technology Data Exchange (ETDEWEB)

Preliminary results from a large-scale testbed of advanced lighting control technologies at the Phillip Burton Federal Building at 450 Golden Gate Ave. in San Francisco are presented. The first year objective of this project is to determine the sustainable energy savings and cost-effectiveness of different lighting control technologies compared to a portion of the building where only minimal controls are installed. The paper presents the analyzed results from six months of tests focused on accurately characterizing the energy savings potential of one type of daylight-linked lighting controls compared to the lighting in similar open-planned areas without dimming controls. After analyzing a half year;s data, we determined that the annual energy savings for this type of daylight- linked controls was 41% and 30% for the outer rows of lights on the South and North sides of the building, respectively. The annual energy savings ...

1998-03-01

307

Pollution prevention opportunity assessment for Building 922 solid office waste  

Energy Technology Data Exchange (ETDEWEB)

Building 922 houses all of SNL/California`s ES and H Departments: Health Protection, Environmental Protection, Safety, and Environmental Operations. It covers approximately 10,000 square feet and houses about 80 people. The office personnel generate nonhazardous solid office wastes in their daily activities. To determine the types and amounts of waste generated, a special PPOA sorting team sorted all of the trash collected from the building for a period of one-week (including paper and aluminum cans in the recycling bins). The team sorted the trash into major categories: paper, plastic, metals, glass, wet garbage, rest room waste, and miscellaneous materials. They then sorted it into subcategories within each major category. Rest room waste was collected but not sorted. The waste in each category was weighed separately. The total amount of trash collected during the week was approximately 168.8 kg (371.4 lbs). The results of this PPOA indicate ...

1995-01-01

308

Plutonium build-up credits for a material test research reactor and influence of cross-section differences on actinide production  

Energy Technology Data Exchange (ETDEWEB)

Burnup calculations with SARC system were carried out to analyse the effects of plutonium build-up on criticality of MTR type research reactor PARR-1 using several WIMSD libraries based on evaluated nuclear data files ENDFB-VI.8, JEF-2.2, JEFF-3.1 and JENDL-3.2. For equilibrium core of the reactor, it was found that a net reactivity of more than 3.5 mk is induced due to build-up of plutonium isotopes during depletion. The plutonium credit amounts to 3% of the length of equilibrium cycle. From the analysis of actinide production in the core during burnup, it was observed that in most of the cases, the amounts of actinides obtained using various cross section libraries agree fairly with each other, however, significant differences were observed for {sup 238}Pu, {sup 241}Pu, {sup 242m}Am, {sup 243}Am, {sup 242}Cm and {sup 244}Cm for some libraries. The actinide chain analysis was conducted to investigate the reasons for the observed differences.

2006-12-15

309

Photovoltaic solar power in building engineering. Experience feedback in France of the European Hip Hip project. Advances and realizations; L'electricite solaire photovoltaique dans le batiment. Retour d'experience en France du Projet Europeen Hip Hip. Avancees et realisations  

Energy Technology Data Exchange (ETDEWEB)

The European demonstration project Hip Hip (house integrated photovoltaic high-tech in public) led the French photovoltaic market to reach a level comparable to those of the other European countries in terms of relevance of implemented solutions and costs. This document presents the best realizations and the experience gained through the Hip Hip project. Its aim is to convince the designers and managers of building projects of the advantages of photovoltaic installations integrated to the structure and connected to the power distribution grid: 1 - presentation of the technology; 2 - status of the Hip Hip demonstration project (goals, results: main innovations and impact on the French market); 3 - different possibilities of integration to the building structure; 4 - examples of projects realized in France in the framework of the Hip Hip project: integration in glass roof, frontage, added elements, fitting on roofs. (J.S.)

2003-07-01

310

Performance analysis on a hybrid air-conditioning system of a green building  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the performance analysis on a hybrid air-conditioning system according to the hybrid building energy system of the green building demonstration project in Shanghai, in which a 150 m{sup 2} solar collector is used to power two 10 kW adsorption chillers, a vapor compression heat pump is used to cool air in the evaporating end while the condensing heating at about 80{sup o}C is fully used to regenerate a liquid desiccant dehumidification system. In the hybrid system, the sensible cooling to the air is treated mainly by solar adsorption cooling and vapor compression cooling, whereas the latent heat is treated by the liquid desiccant dehumidification system with regeneration from the condensing heat of the heat pump. The results show that the performance of this system is 44.5% higher than conventional vapor compression system at a latent load of 30% and this improving can be achieved by 73.8% at a 42% latent load. The optimal ...

2006-05-15

311

One-piece removal of JRR-3 reactor block  

Energy Technology Data Exchange (ETDEWEB)

JRR-3 is a research reactor of 10 MWt output, which attained the criticality in 1962. All the design, manufacture, installation and others of this reactor were carried out by Japanese technologies, except the fuel and heavy water as the moderator and coolant, therefore it is nicknamed Home-made No.1 Reactor. Recently, due to the change in the state of utilizing research reactors and the rise of quality in the utilization, JRR-3 has become to be unable to meet sufficiently the needs of users. The plan of reconstructing the JRR-3 was considered under such situation, and in order to reuse the reactor building, the reactor proper is removed, and an entirely new, high performance, versatile reactor is to be constructed. In this paper, as to the removal works of the JRR-3 reactor proper, the method of execution, design, the execution of works and so on are outlined. The removal works of the reactor facilities were started in February, 1986. The removal of the accessory ...

1987-07-01

312

Microclimatic conditions at the external surface of building envelopes  

Energy Technology Data Exchange (ETDEWEB)

The project is described, the motivation for the research and the microclimate is defined in relation to both building physics research and applications. Air temperatur, air humidity, solar radiation and air velocity are briefly considered, whilst driving rain and long-wave radiation are described in more detail. Convective heat transfer and surface coefficients are discussed, although they are not microclimatic factors, merely resulting from combinations of such factors. They are included as they are important in relation to transfer of heat and moisture at the surface of the building envelope. Driving rain measurement is the main area of interest, including development of measurement equipment. Long-wave irradiation is measured and compared with empirical formulae from the literature. Window convection heat transfer is another main area of interest. Nocturnal convective heat transfer from a double pane glazing is studied and measurement ...

1998-12-31

313

Large temperature differential thermal storage system. Its design and evaluation  

Energy Technology Data Exchange (ETDEWEB)

A large temperature differential (10K) thermal storage system in a small (4400 m{sup 2}) 8-storey office building is discussed and the monitoring results are analyzed in comparison with computer simulations. Requirements were a comfortable indoor environment and system cost effectiveness. Out of four potential system concepts, the Large Temperature Differential System was chosen. It comprises a flat-type thermal stratification heat storage tank in the under floor pit of the building as the heat source for a variable flow heat pump chiller. The heat sink is a set of serially connected air handling and fan coil units. The tank`s capacity is sized for one day operation and is made as large as possible to shift the electricity demand to night time. To avoid a large size and high cost, the water temperature differential was enlarged. The role of Tokyo Electric Power Company (TEPCO) was to develop the chiller and its control system. It is concluded ...

1996-07-01

314

Heavy water reactor facility large-scale containment cooling test program  

Science.gov (United States)

The Heavy Water Reactor Facility (HWRF), as part of the defense-in-depth philosophy to mitigate the effect of design-basis and severe accidents, is equipped with a passive containment cooling system (PCCS). The function of the PCCS is to provide a safety-grade path to the ultimate heat sink for the removal of the reactor coolant system sensible heat and core decay heat. Ambient air enters an annular space between the steel containment shell and the surrounding concrete shield building through inlets in the shield building wall, is heated via natural convection, rises, and exits the building through a chimney located above the containment dome. A test program is in place to access parameters important to the effective operation of the PCCS. This paper focuses on the large-scale tests (LSTs). The objectives of these tests are as follows: (1) demonstrate natural circulation cooling with more prototypic cylinder and dome ...

1992-01-01

315

Heavy water reactor facility large-scale containment cooling test program  

International Nuclear Information System (INIS)

The Heavy Water Reactor Facility (HWRF), as part of the defense-in-depth philosophy to mitigate the effect of design-basis and severe accidents, is equipped with a passive containment cooling system (PCCS). The function of the PCCS is to provide a safety-grade path to the ultimate heat sink for the removal of the reactor coolant system sensible heat and core decay heat. Ambient air enters an annular space between the steel containment shell and the surrounding concrete shield building through inlets in the shield building wall, is heated via natural convection, rises, and exits the building through a chimney located above the containment dome. A test program is in place to access parameters important to the effective operation of the PCCS. This paper focuses on the large-scale tests (LSTs). The objectives of these tests are as follows: (1) demonstrate natural circulation cooling with more prototypic cylinder and dome ...

1992-11-15

316

Hawaii demand-side management resource assessment. Final report, Reference Volume 2: Final residential and commercial building prototypes and DOE-2.1E developed UECs and EUIs; Part 3  

Energy Technology Data Exchange (ETDEWEB)

This section contains the detailed measured impact results and market segment data for each DSM case examined for this building type. A complete index of all base and measure cases defined for this building type is shown first. This index represents an expansion of the base and measure matrix presented in Table 1 (residential) or Table 2 (commercial) for the applicable sector. Following this index, a summary report sheet is provided for each DSM measure case in the order shown in the index. The summary report sheet contains a host of information and selected graphs which define and depict the measure impacts and outline the market segment data assumptions utilized for each case in the DBEDT DSM Forecasting models. The variables and figures included in the summary report sheet are described. Numerous tables and figures are included.

1995-04-01

317

Hawaii demand-side management resource assessment. Final report, Reference Volume 2: Final residential and commercial building prototypes and DOE-2.1E developed UECs and EUIs; Part 2  

Energy Technology Data Exchange (ETDEWEB)

This section contains the detailed measured impact results and market segment data for each DSM case examined for this building type. A complete index of all base and measure cases defined for this building type is shown first. This index represents an expansion of the base and measure matrix presented in Table 1 (residential) or Table 2 (commercial) for the applicable sector. Following this index, a summary report sheet is provided for each DSM measure case in the order shown in the index. The summary report sheet contains a host of information and selected graphs which define and depict the measure impacts and outline the market segment data assumptions utilized for each case in the DBEDT DSM Forecasting models. The variables and figures included in the summary report sheet are described. Numerous tables and figures are included.

1995-04-01

318

Formaldehyde exposure from building products  

Energy Technology Data Exchange (ETDEWEB)

Formaldehyde release from building products is primarily due to incompletely reacted urea-formaldehyde resin (UFR) in particleboard, medium density fiberboard (MDF), and plywood. Formaldehyde is also released from urea-formaldehyde foam insulation (UFFI) that was popular during the 1970s for retrofitting building envelopes. Results of the authors test of commercial adhesives and UF-bonded wood products show that current state-of-the-art products yield air chamber test values below 0.25 mg/m/sup 3/ immediately after manufacture and are capable of meeting 0.12 mg/m/sup 3/ indoor air standards at the current product ratio unless these products are used in places where they are exposed to high temperature and humidity. In mobile homes placed in severe climates, wall-temperature profiles show large seasonal and diurnal variations that cause large changes in formaldehyde indoor air levels. The authors work shows that diurnal formaldehyde levels may ...

1986-01-01

319

Designing a healthy house - an overview  

Energy Technology Data Exchange (ETDEWEB)

There are certain factors to take into account when determining the suitability of a healthy house site. Power lines, agricultural spraying, vehicle exhaust, and industrial pollution are all potential sources of indoor air contamination. It is recommended that a environmental assessment be done to determine whether there are specific sources of contamination. Good drainage is required. The surrounding landscaping should be open and sunlit, and with low maintenance requirements. Decks and fences made from pressure-treated or chemical treated lumber should be avoided. One of the early decisions in the design process is the choice of the structural system. The key with all foundation types is to control moisture, whether from rain, from the ground, or the condensation of moisture from the air with cooling. The construction frame is sealed away from the occupants by the air/vapor barrier, so only in extreme cases is it essential to use alternatives to softwood lumber for framing exterior ...

1999-11-01

320

Design and performance of a solar-powered air-conditioning system in a green building  

Energy Technology Data Exchange (ETDEWEB)

A solar-powered adsorption air-conditioning system was designed and installed in the green building of Shanghai Research Institute of Building Science. The system contained 150 m{sup 2} solar collectors and two adsorption chillers with nominal refrigeration capacity of 8.5 kW. Based on performance characteristics of the adsorption chiller, the operation mode of the solar-powered air-conditioning system was optimized by maintaining a phase shift of 540 s between the two adsorption chillers. Thereafter, the whole system realized stable operation by the balance of heat consumption and refrigeration output. From June to August of 2005, the solar-powered air-conditioning system continuously ran between 9:00 and 17:00. The operation performance of the system under representative working condition showed that the average refrigeration output of the solar-powered air-conditioning system was 15.3 kW during an 8 h operation and the maximum value exceeded ...

2008-05-15

321

Control of population dose equivalent from naturally occurring radionuclides in building materials  

International Nuclear Information System (INIS)

Naturally occurring radionuclides in building materials are a source of external and interal radiation exposure to essentially the entire US population. Although detailed data are not available, estimates are that the average contribution from such sources to the external dose equilvaent rate in brick and masonry houses is about 5 to 10 mrem/year. For critical population groups, values reported in the literature for the contribution from such sources range up to a hundred mrem/year or more. Dose equivalent rates to the lungs are even higher and, for abnormal situations, it would appear that control measures, either on a voluntary or mandatory (legislative) basis should be considered. Such measures include: (1) material substitution; (2) improved manufacturing standards; (3) changes in basic building designs; (4) application of surface sealants; and (5) increased ventilation accompanied by processes for the adsorption and/or filtration of ...

322

Computer-tools for calculating quantities, energy and humidity. Working report; Edb-vaerktoej til beregning af maengder, energi og fugt; Arbejdsrapport  

Energy Technology Data Exchange (ETDEWEB)

The overall aim is to develope programme modules for a Danish integrated computer system for projecting buildings and to ensure that Danish programmes are compatible with international systems. The programmes to be integrated here were AutoCAD and SCRIBE-models and the simulation programme tsbi3 for the calculation of indoor climate conditions, power demand and energy consumption in buildings. For the calculation of humidity and temperature conditions in constructions a certain amount of integration is carried out with the MATCH programme (Moisture And Temperature calculations for Constructions of Hygroscopic materials). The activities embodied in the pilot projects are described in this working report in addition to the individual computer programmes and prototypes, and examples and diagrams are presented. The programmes included are a geometry programme for the calculation of areas, lengths and volumes, a programme for the calculation of heat ...

1993-03-01

323

CFD investigation of unstable airflow due to temperature difference via horizontal openings  

Energy Technology Data Exchange (ETDEWEB)

Air flow and the buoyancy-driven flow through a building`s horizontal openings was discussed. Horizontal openings occur in staircases, stairwells, ventilation shafts and chimneys. Mass and energy transfer through them have important implications regarding energy saving, thermal comfort, control of contaminants and micro-organisms and spread of fire and smoke. The analysis of the buoyancy-driven flow was attained using computational fluid dynamics (CFD). Use was made of the CFD code FLUENT which integrated the Navier-Stokes equations by a time-dependent, finite volume method. Good agreement was achieved between predicted and experimental measurements of flow rate. Results showed that flow patterns in horizontal openings were transient and unstable. The air exchange through the openings occurred in intermittent pulses. The flow rate through the opening increased with the temperature difference between zones in buildings and the size of the ...

1995-12-31

324

Analytical study on analysis methods of several random variables for seismic nonlinear responses of reactor buildings  

International Nuclear Information System (INIS)

In the case wherein nonlinear seismic response analyses are carried out, the response values vary due to the variations in materials and modeling. In this paper, nonlinear analyses of several random variables are carried out using: i. a conventional method; ii. a two-point estimation method (i. and ii. are simplified methods); and iii. Monte Carlo simulation (detailed method) to examine the variability of the response in the excessive nonlinear range for seismic responses of shear walls. The analyses are performed to a PWR-3 loop type reactor building which is one of the most typical reactor buildings in Japan. The variations are considered in specified compressive strength of concrete, concrete damping factor, shear wave velocity of soil and shapes of shear stress-strain relation curves of shear walls. As the results by the two simplified methods closely matched the Monte Carlo simulation results, the appropriateness for applying the ...

1993-08-15

325

Analysis of dose rate build-up in Tarapur Atomic Power Station unit-4  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station Unit-4 was made critical on 6th March 2005. Since radiation field builds up with the power level due to formation of fission products and activation products in different systems. Radiation dose rates were recorded from different areas using Area Radiation Monitors (ARMs) installed at different areas. These monitors are connected to Radiation Data Acquisition System (RADAS). The trend of radiation field build-up was also analyzed by making survey of different plant areas at various power levels and comparison was made with RADAS readings. The results obtained were compared with 220 MWe dose rates. This study discusses about the dose rates observed at accessible area, shut down accessible area and hotspots observed during the early stage of operation of the reactor. The attempt was also made to find the contributing factors of the high dose rates. It was found that the finding of the study was utilized for the ...

2005-11-23

326

Analyses of postulated accidental releases of UF6 inside process buildings  

International Nuclear Information System (INIS)

Uranium Hexafluoride is a material used in the various processes which comprise the front end of the nuclear fuel cycle (conversion, enrichment and fuel fabrication). Confinement of UF6 is a very important safety requirement since this material is highly reactive and presents safety hazards to humans. The present paper discusses the safety relevant aspects of accidental releases of UF6 inside process confinement buildings. Postulated accidental scenarios are analyzed and their consequences evaluated. Implant releases rates are estimated using computer code predictions. A time dependent homogeneous compartment model is used to predict concentrations of UF6, hydrogen fluoride and uranyl fluoride inside a confinement building, as well as to evaluate source terms released to the atmosphere. These source terms can be used as input to atmospheric dispersion models to evaluate consequences to the environment. The results can also be used to define ...

327

Advanced fuzzy logic controllers design and evaluation for buildings' occupants thermal-visual comfort and indoor air quality satisfaction  

Energy Technology Data Exchange (ETDEWEB)

The aim of this paper is to present and evaluate control strategies for adjustment and preservation of air quality, thermal and visual comfort for buildings' occupants while, simultaneously, energy consumption reduction is achieved. Fuzzy PID, fuzzy PD and adaptive fuzzy PD control methods are applied. The inputs to any controller are: the PMV index affecting thermal comfort, the CO{sub 2} concentration affecting indoor air quality and the illuminance level affecting visual comfort. The adaptive fuzzy PD controller adapts the inputs and outputs scaling factors and is based on a second order reference model. More specifically, the scaling factors are modified according to a sigmoid type function, in such a way that the measured variable to be as closer as possible to the reference model. The adaptive fuzzy PD controller is compared to a non-adaptive fuzzy PD and to an ON-OFF one. The comparison criteria are the energy required and the controlled variables ...

2001-07-01

328

Willingness to pay for energy-saving measures in residential buildings  

Energy Technology Data Exchange (ETDEWEB)

This paper uses a choice experiment to evaluate the consumers' willingness to pay for energy-saving measures in Switzerland's residential buildings. These measures include air renewal (ventilation) systems and insulation of windows and facades. Two groups of respondents consisting respectively of 163 apartment tenants and 142 house owners were asked to choose between their housing status quo and each one of the several hypothetical situations with different attributes and prices. The estimation method is based on a fixed-effects logit model. The results suggest that the benefits of the energy-saving attributes are significantly valued by the consumers. These benefits include both individual energy savings and environmental benefits as well as comfort benefits namely, thermal comfort, air quality and noise protection. (author)

2008-03-15

329

Verification of knowledge bases based on containment checking  

Energy Technology Data Exchange (ETDEWEB)

Building complex knowledge based applications requires encoding large amounts of domain knowledge. After acquiring knowledge from domain experts, much of the effort in building a knowledge base goes into verifying that the knowledge is encoded correctly. We consider the problem of verifying hybrid knowledge bases that contain both Horn rules and a terminology in a description logic. Our approach to the verification problem is based on showing a close relationship to the problem of query containment. Our first contribution, based on this relationship, is presenting a thorough analysis of the decidability and complexity of the verification problem, for knowledge bases containing recursive rules and the interpreted predicates =, {le}, < and {ne}. Second, we show that important new classes of constraints on correct inputs and outputs can be expressed in a hybrid setting, in which a description logic class hierarchy is also considered, and we ...

1996-12-31

330

Ventilation as a means of air-conditioning power saving in reinforced concrete telephone-exchange buildings analysis and directions for design  

Energy Technology Data Exchange (ETDEWEB)

The paper presents a computer-aided analysis of the combined use of ventilation and structural heat capacity and insulation as a means of saving air-conditioning power in digital telephone exchanges. It is shown that such savings can be effected by increasing air change with outdoor cool air at night, and when feasible, also in daytime, through the air change unit, in a conventional airconditioning cycle. The total thermal time constant (TTTC) method of calculation used enables the evaluation of daily or seasonal heat-flow balance for a given indoor temperature, considering the tendency of the heat capacity of the building and of envelope components to flatten the fluctuations of this temperature.

1984-12-01

331

Using Floor Cooling as an Approach to improve the Thermal Environment in the Sleeping Area in an Open Pig House  

British Library Electronic Table of Contents (United Kingdom)

In order to provide pigs a comfortable sleeping area in hot weather, a floor cooling system was designed and applied to production buildings. Experiments were conducted to compare the floor temperatures and to observe the lying behaviour of pigs in the sleeping area of the buildings with and without floor cooling system. The results showed that, without the floor cooling system, the floor temperature was nearly the same as the air temperature in the open pig house. With the floor cooling system, the floor temperature of the sleeping area was controlled at 22-26degreeC, even though the air temperature was as high as 34degreeC, which improved the comfort of the pigs in the sleeping area. The pig lying behaviour was greatly affected by the floor temperature. More than 85% of the pigs were lyi...

2006-01-01

332

Unravelling the complexity of collective mental models: A method for developing and analysing scenarios in multi-organisational contexts  

British Library Electronic Table of Contents (United Kingdom)

In multi-organisational contexts, scenario building has been used to engage stakeholders in a critical discussion on issues of mutual importance, and to gain their support with regards to possible future responses. A review of existing literature suggests that much has been written regarding the process of scenario development and the benefits of the process, but the detailed analysis of scenario building outcomes, which encompass a large number of issues and their complex interconnections, has not been made explicit for studying and enhancing understanding of a complex societal problem. This paper presents a systematic method for analysing such complex outcomes in order to facilitate reflective thinking on important issues within the wider context for policy development. The method was em...

2011-01-01

333

Study on tritium activity build-up in moderator and primary heat transport systems in 540 MWe reactor  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station unit-4 is first 540 MWe pressurized heavy water reactor. Heavy water is used as the coolant and moderator. With reactor operation tritium is formed by absorption of neutron by Deuterium atoms. Experience in the 220 MWe indicates that tritium is main contributor to the internal dose of radiation workers. Study on Tritium build up in Primary Heat Transport (PHT) and Moderator (MOD) system was carried out at the initial stage of the operation of the unit-3 and 4. This paper brings out tritium activity buildup in the PHT and MOD systems and its comparison with 220 MWe reactors. This paper helps in estimation of the internal dose contribution to the radiation workers at TAPS 3 and 4. (author)

2006-11-13

334

Study on tritium activity build-up in moderator and primary heat transport (PHT) systems in 540 MWe reactor  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station unit-4 is first 540 MWe pressurized heavy water reactor. Heavy water is used as the coolant and moderator. With reactor operation tritium is formed by absorption of neutron by deuterium atoms. Experience in the 220 MWe indicates that tritium is main contributor to the internal dose of radiation workers. Study on tritium build up in Primary Heat Transport (PHT) and Moderator (MOD) system was carried out at the initial stage of the operation of the unit-4. This paper brings out tritium activity buildup in the PHT and MOD systems and its comparison with 220 MWe reactors. This paper helps in estimation of the internal dose contribution to the radiation workers at TAPS 3 and 4. (author)

2005-11-23

335

Some significant environmental issues in high-rise residential building design in urban areas  

Energy Technology Data Exchange (ETDEWEB)

Almost in all the major cities in Asian countries, residential buildings are characterized with high-rise and high density. Under this circumstance, achieving comfortable and healthy indoor environment with minimized energy consumption becomes a very challenging engineering and societal issue. While the wide use of air-conditioning helped to improve thermal comfort, health problems associated with poor indoor air qualities have appeared more frequently. The increased energy consumption is also a great concern in view of its impact on the energy economics of the region. Drawn from some of the onsite measurements and survey, and also the author's personal observation, some of the key issues are discussed in this paper. (author)

2004-12-01

336

Soft factor 'felt comfort'. Room air quality, an important element; Soft-Factor Wohlbefinden. Raumluftqualitaet als wichtige Grundlage  

Energy Technology Data Exchange (ETDEWEB)

Facility management has long been regarded as a cost reduction measure, but it is also a means of raising the financial worth of a building so that landlords can get higher rents or sell the building at a better price. [German] Lange Zeit wurde Facility Management als eine Massnahme zur Kostensenkung angesehen. Heutzutage zeigt sich immer mehr, dass das Facility Management sehr viel umfassender zu verstehen ist: Der Wert eines Gebaeudes bemisst sich nicht allein an einer niedrigen Kostenquote, sondern er soll umfassend Investoren wie Mietern den hoechst moeglichen Nutzen bringen. Nicht allein der kostenguenstige Betrieb ist entscheidend, sondern der Wert des Gebaeudes muss insgesamt gesteigert werden. (orig.)

2002-07-01

337

Seismic tests of post-tensioned self-centering building frames with column and slab restraints  

British Library Electronic Table of Contents (United Kingdom)

Post-tensioned (PT) self-centering moment frames have been developed as an alternative to typical moment-resisting frames (MRFs) for earthquake resistance. When a PT frame deforms laterally, gaps between the beams and columns open. However, the gaps are constrained by the columns and the slab in a real PT self-centering building frame. This paper presents a methodology for evaluating the column restraint and beam compression force based on the column deformation and gap openings at all stories. The method is verified by cyclic tests of a full-scale, two-bay by one-story PT frame. Moreover, a sliding slab is proposed to minimize restraints on the expansion of the PT frame. Shaking table tests were conducted on a reduced-scale, two-by-two bay one-story specimen, which comprises one PT frame ...

2011-01-01

338

Revisiting an old hypothesis of human thermal perception: alliesthesia  

British Library Electronic Table of Contents (United Kingdom)

Many new technologies and approaches to the provision of comfort inside buildings such as displacement ventilation, mixed-mode strategies, personally controllable (task-ambient) designs, chilled beams as well as some old but recently fashionable ones such as natural ventilation are prompting a rethink of the accepted comfort wisdom. How can a single combination of thermal environmental parameters be deemed unacceptable in a conventional heating ventilation and air-conditioning setting, and yet be regarded as acceptable, or even pleasant, in a naturally ventilated or mixed-mode setting? Why do current comfort standards prescribe static and isothermal conditions for comfort in one building, and dynamic and spatially variable indoor climates for comfort in another? The phenomenon of alliesthe...

2011-01-01

339

Respiratory exposure in buildings due to radon progeny  

International Nuclear Information System (INIS)

The #alpha# radiation dose to the lungs of people who live in buildings constructed of some granites, low density concretes, and gypsum boards is higher than for residents of most other types of dwellings due to the air-borne progeny of radon. There is evidence that sealing the interior surfaces with epoxy paint, for example, can reduce the #alpha# dose to the lung significantly without a compensating increase in whole-body exposure to the #gamma#-rays from radon progeny. Based on the incidence rates for lung cancer in uranium miners, a concentration of radon of the order of 1 to 5 pCi/l. appears to be a reasonable limit for 'lifetime' exposure indoors for 'typical' home ventilation conditions. (author).

1976-01-01

340

Realization of good indoor climate in low-energy office  

Energy Technology Data Exchange (ETDEWEB)

Good indoor air quality and thermal comfort, as well as low energy consumption, were achieved in an environment friendly experimental METOP-office building in Espoo, Finland. The consumption of heating and cooling energy was minimized by installation of energy-efficient windows, good CFC-free thermal insulation of the building envelope, the individually-controlled ventilation and room temperatures, heat recovery and energy-storing structures. According to the study carried out in 1990-1993, the heating energy was 13 kWh/m{sup 3}, 60% lower than the average consumption. The index of the satisfaction of thermal comfort was over 90%. Concentrations of all the measured indoor air pollutants were low. Ventilation rates could be chosen in each office room from 10 to 40 dm{sup 3}/s. The noise level of the ventilation system was low and the lighting level was pleasant. (author)

1994-12-31

341

Radon diffusion studies through building construction materials using solid state nuclear track detectors  

International Nuclear Information System (INIS)

Radon appears mainly by diffusion processes from the point of origin following #alpha#- decay of "2"2"6Ra in underground soil and building materials used, in the construction of floors, walls, and ceiling. The transport phenomenon of radon through diffusion is a significant contributor to indoor radon entry. In the present study radon diffusion through sand, cement, mixtures of sand + cement (1:1), sand + cement (2:1), sand + cement (3:1), sand + cement (4:1) has been carried out using LR-115 type II solid state nuclear track detectors (SSNTDs). The radon diffusion coefficient and diffusion lengths have been calculated for different materials. The effect of compaction, which changes the porosity and permeability of the materials, on radon diffusion has also been studied. (author)

2003-10-16

342

Radon Levels and Related Doses in a Prototype Jamaican House Constructed with Bauxite Waste Blocks  

Energy Technology Data Exchange (ETDEWEB)

Measurements are presented of indoor radon levels made in a prototype house constructed partly of bauxite waste (red mud) and partly of conventional materials. The mud used contains higher than the average amounts of {sup 226}Ra and {sup 232}Th found in local building materials. The rates of exhalation of radon from the material used in the construction of the house are measured and employed with measured air change rates to make estimates of the average contribution of the various materials to the measured radon levels indoors. There is fairly good agreement between the two. The increment of radon related dose equivalents above background are also estimated and these are combined with previously determined gamma dose equivalents and used as a basis for assessing the acceptability of the practice of using red mud as a building material. (author)

1999-07-01

343

Radon Levels and Related Doses in a Prototype Jamaican House Constructed with Bauxite Waste Blocks  

International Nuclear Information System (INIS)

Measurements are presented of indoor radon levels made in a prototype house constructed partly of bauxite waste (red mud) and partly of conventional materials. The mud used contains higher than the average amounts of "2"2"6Ra and "2"3"2Th found in local building materials. The rates of exhalation of radon from the material used in the construction of the house are measured and employed with measured air change rates to make estimates of the average contribution of the various materials to the measured radon levels indoors. There is fairly good agreement between the two. The increment of radon related dose equivalents above background are also estimated and these are combined with previously determined gamma dose equivalents and used as a basis for assessing the acceptability of the practice of using red mud as a building material. (author)

344

Radiation hardening of smart electronics  

International Nuclear Information System (INIS)

Microprocessor based ''smart'' pressure, level, and flow transmitters were tested to determine the radiation hardness of this class of electronic instrumentation for use in reactor building applications. Commercial grade Complementary Metal Oxide Semiconductor (CMOS) integrated circuits used in these transmitters were found to fail at total gamma dose levels between 2500 and 10,000 rad. This results in an unacceptably short lifetime in many reactor building radiation environments. Radiation hardened integrated circuits can, in general, provide satisfactory service life for normal reactor operations when not restricted to the extremely low power budget imposed by standard 4--20 mA two-wire instrument loops. The design of these circuits will require attention to vendor radiation hardness specifications, dose rates, process control with respect to radiation hardness factors, and non-volatile programmable memory technology. 3 refs., 2 figs.

345

RESRAD model presentation  

Energy Technology Data Exchange (ETDEWEB)

RESRAD was one of the multimedia models selected by the US Nuclear Regulatory Commission (NRC) to include in its workshop on radiation dose modeling and demonstration of compliance with the radiological criteria for license termination. This paper is a summary of the presentation made at the workshop and focuses on the 10 questions the NRC distributed to all participants prior to the workshop. The code selection criteria, which were solicited by the NRC, for demonstrating compliance with the license termination rule are also included. Among the RESRAD family of codes, RESRAD and RESRAD-BUILD are designed for evaluating radiological contamination in soils and in buildings. Many documents have been published to support the use of these codes. This paper focuses on these two codes. The pathways considered, the databases and parameters used, quality control and quality assurance, benchmarking, verification and validation of these codes, and ...

1998-05-01

346

Profiling gene expression responses of coral larvae (Acropora millepora) to elevated temperature and settlement inducers using a novel RNA-Seq procedure  

British Library Electronic Table of Contents (United Kingdom)

Abstract Elevated temperatures resulting from climate change pose a clear threat to reef-building corals; however, the traits that might influence corals- survival and dispersal during climate change remain poorly understood. Global gene expression profiling is a powerful hypothesis-forming tool that can help elucidate these traits. Here, we applied a novel RNA-Seq protocol to study molecular responses to heat and settlement inducers in aposymbiotic larvae of the reef-building coral Acropora millepora. This analysis of a single full-sibling family revealed contrasting responses between short- (4-h) and long-term (5-day) exposures to elevated temperatures. Heat shock proteins were up-regulated only in the short-term treatment, while the long-term treatment induced the down-regulation of rib...

2011-01-01

347

Passive solar design handbooks: Vol III: passive solar design analysis and supplement  

Energy Technology Data Exchange (ETDEWEB)

This book applies the Los Alamos Solar Load Ratio (SLR) method to the design of passive solar heating systems, with an emphasis on the average annual heating energy consumption. Recommendations are given on minimizing heating energy consumption by appropriate choices of conservation level and solar system parameters. Analytical methods and supporting tables are presented which enable simple, fast estimates of the heating energy consumption as part of the design process. Topics considered include SLR correlations, the load collector ratio (LCR) method, sensitivity data, cooling considerations, conservation formulas, design procedure, life-cycle costs, high-mass direct gain buildings, low-mass sun-tempered buildings, sunspaces, off-reference night insulation, correlation equations, and mixed systems.

1983-01-01

348

Overview on seismic evaluation and retrofitting within JICA Technical Cooperation Project on reduction of seismic risk in Romania  

International Nuclear Information System (INIS)

The objective of this paper is to give an overview on the seismic evaluation and retrofitting procedures of reinforced concrete buildings within JICA technical cooperation project in Romania. The content of the paper covers a) an outline of the seismic evaluation; history and comparison of Romanian seismic design codes with the Japanese seismic evaluation guidelines, b) an outline of the retrofitting techniques which were transferred from Japan to Romania and structural tests for retrofitting techniques employed in Romania and c) retrofitting details that were used by JICA/NCSRR in the retrofitting design of two vulnerable buildings in Bucharest. The above-mentioned retrofitting projects are now under development of detailed design and therefore, in the near future, refining and improvement of solutions will be performed. (authors)

2007-04-26

349

On the long term indoor radon concentration measurements in the basement HVAC machine room of commercial buildings using a passive monitor method  

International Nuclear Information System (INIS)

Long term indoor radon gas measurements using a passive monitor are now being conducted in the basement HVAC machine rooms of about fifty commercial buildings, which are built in the Tokyo and Nagoya metropolitan area. Ventilation rates are also measured during the monitoring period. The earliest results show that the highest concentration was about twice of the EPA Standards and was obtained at Nagoya in autumn and no clear seasonal change was seen in radon concentration so far, and that the correlation between radon concentration and inverse number of ventilation rate was positive but not high. (orig.). (2 refs., 4 figs., 2 tabs.).

1993-07-04

350

Multiobjective design of Work-In-Process buffer for scheduling repetitive building projects  

British Library Electronic Table of Contents (United Kingdom)

Variability in production is one of the largest factors that negatively impacts construction project performance. A common construction practice to protect production systems from variability is the use of buffers (Bf). Construction practitioners and researchers have proposed buffering approaches for different production situations, but these approaches have faced practical limitations in their application. A multiobjective analytic model (MAM) is proposed to develop a graphical solution for the design of Work-In-Process (WIP) Bf in order to overcome these practical limitations to Bf application, being demonstrated through the scheduling of repetitive building projects. Multiobjective analytic modeling is based on Simulation?Optimization (SO) modeling and Pareto Fronts concepts. Simulation...

2009-01-01

351

Issues in food irradiation  

International Nuclear Information System (INIS)

This discussion paper has two goals: first, to raise public awareness of food irradiation, an emerging technology in which Canada has the potential to build a new industry, mainly oriented to promising overseas markets; and second, to help build consensus among government and private sector decision makers about what has to be done to realize the domestic and export potential. The following pages discuss the potential of food irradiation; indicate how food is irradiated; outline the uses of food irradiation; examine questions of the safety of the equipment and both the safety and nutritional value of irradiated food; look at international commercial developments; assess the current and emerging domestic scene; and finally, draw some conclusions and offer suggestions for action.

1995-10-01

352

General flow and thermal boundary conditions in indoor air flow simulation  

Energy Technology Data Exchange (ETDEWEB)

The concepts of general flow and thermal boundary conditions are introduced to treat the interaction between indoor and outdoor thermal environments in computational fluid dynamics (CFD) simulations. The results from a multi-zone model are used to supply the general flow boundary conditions. The energy balance equation at wall-air interfaces is used to supply the general thermal boundary conditions. An example calculation in a 13-room building shows that infiltration influences indoor air flow patterns considerably. The air flow in a room ventilated by displacement is measured and simulated. Two surface coatings are considered, i.e. black walls and aluminum walls. Implementation of these two boundary conditions is essential in predicting air flow patterns, air quality, and thermal comfort in a real building. (author)

1994-12-31

353

Gas chromatography - mass-spectrometry of volatiles released from plastics used as building materials  

Energy Technology Data Exchange (ETDEWEB)

The possibility of employing a number of adsorbents (polyphenylquinoxaline, Tenax GC, Carbopak C, graphitized thermal carbon black, silica gels modified with pyrocarbon or hexamethyldisilazane) for the trapping of organic traces from air has been investigated. Adsorption capacities of these adsorbents with respect to a number of volatiles released from certain plastics used as building material (polyvinylchloride, Relin, Acronal, etc.) have been measured. A number of the volatiles were identified by gas chromatography - mass-spectrometry after trapping on the adsorbents investigated. Chromatographic separation after trapping on the adsorbents was carried out on wall-coated open-tubular capillary columns as well as in capillary columns packed with graphitized thermal carbon black.

1983-10-01

354

Engineers Australia  

Wastenet

... Jillian Kilby is a civil engineer and director of J L Kilby Pty Ltd based between Walgett and Brewarrina in North West NSW. Building an engineering company in rural NSW combines Jillianrsquo;s passions for quality projectengineering services, and rural communities. It is also testament to her determination to build a career no matter where she chose to live. Her company has a strong focus on improving ... Some of Jillianrsquo;s recent projects include involvement in an alternate inland highway feasibility study, a water study at Brewarrina, a multipurpose jetty tender in Wyndham, Western Australia, and project management of the SES yard development in Walgett. Jillian is involved in Engineers Australiarsquo;s Sydney Division. She was the chairman of the Civiland Structural Panel in 2009, is a current board member of the ...

355

Energy saving self-powered industrial dehumidifier  

Energy Technology Data Exchange (ETDEWEB)

An energy saving self-powered industrial dehumidifier for use in a building having a tap water conduit leading from a source of supply to utilization points is described comprising: a dehumidifying apparatus positioned in a stream of air to be dehumidified in the building. The dehumidifying apparatus comprising conduit means for diverting at least a portion of a relatively continuously moving stream of tap water from the tap water conduit through a heat exchanger positioned in a stream of air and returning the diverted portion to the tap water stream upstream of the utilization points. Water vapor in the stream of air will condense onto the heat exchanger when the tap water has a temperature below a dew point temperature of the air stream, thereby dehumidifying the air stream.

1988-07-26

356

Energy from garbage tempts CPI firms. [Niagara Falls, New York  

Energy Technology Data Exchange (ETDEWEB)

This article comments on the fact that there are only 17 energy-from-waste installations in operation in the U.S. and in this respect it lags behind other industrialized nations. Explanations for this gap include the relatively inexpensive garbage disposal as landfill, operating difficulties of some early plants and the high cost of building such facilities. There has been a recent push to build resource-recovery plants and it is believed that chemical companies will probably buy energy products from such plants. Hooker Chemical Co's new energy-from-waste plant at Niagra Falls, N.Y. is described, other companies involved in resource-recovery projects are mentioned, and it is hoped that more companies will invest in such plants.

1980-09-22

357

Energy absorption characteristics of high damping rubber damper for vibration control of high rise buildings  

International Nuclear Information System (INIS)

The research and development of a new type of high damping rubber damper for high rise buildings/structures to mitigate earthquake or wind-induced structural response is described in this paper. The static tests were carried out to investigate restoring force characteristics using scale model of high damping rubber damper. The repetitive tests and the temperature dependency tests were carried out to investigate variance of performance of energy absorption. It is confirmed that the damping force characteristics of the damper can be considered as that of linear viscous damping and the damper sufficiently dissipates energy for vibrations of mm order to that of generating 200% shear strain. The design methods, based on assuming linear viscous damping for the damper, has been developed. The designed values such as stiffness and damping coefficient of the damper agree well with the experimental results. (author)

1993-08-15

358

Dismantling by explosives  

Energy Technology Data Exchange (ETDEWEB)

Explosives have rarely been used in decommissioning of nuclear reactors. Nevertheless, controlled blasting can be used advantageously during careful destruction of nuclear power plants for removal of concrete, pipe systems, and other components. Experiments performed within a former nuclear power plant demonstrate the feasibility of this method, employing explosive masses up to 15 kg per blast. The loadings of the components and the total plant structure were measured and compared with code predictions. The experiments show a response of the containment predominantly in frequency ranges above 100 Hz, thus keeping the building and components below German regulation limits for shock excitation. The blast wave pressures are reduced drastically within short distances in the building. Dust and debris can be contained with simple methods such as curtains. Use of this method seems to be applicable to actual dismantling projects.

1989-08-01

359

Development of Seismic Analysis Model and Time History Analysis for KALIMER-600  

Energy Technology Data Exchange (ETDEWEB)

This report describes a simple seismic analysis model of the KALIMER-600 sodium cooled fast reactor and its application to the seismic time history analysis. To develop the simple seismic analysis model, the detailed 3-D finite element analyses for main components, IHTS piping system, and reactor building were carried out to verify the dynamic characteristics of each part of simple seismic analysis models. By using the developed simple model, the seismic time history analyses for both cases of a seismic isolation and non-isolation design of KALIMER-600 were performed. From the comparison of the calculated floor response spectrum, it is verified that the seismically isolated KALIMER-600 reactor building shows a great performance of a seismic isolation and assures a seismic integrity.

2007-02-15

360

Control Centre operations as the focus for building station teamwork - issues and resource impacts  

Energy Technology Data Exchange (ETDEWEB)

Effective teamwork among station work groups is essential for plant production and safety in all phases of plant operation. To achieve effective teamwork, all contributing work groups must have ongoing access to and share a common perspective on station work priorities, and recognize how their individual contributions fit with and support the contributions of other groups in support of the larger station goals. Achieving and maintaining this alignment in perspective across all workgroups can be a challenge in large organizations. This paper discusses the experience at Darlington in building and maintaining station teamwork among the station workgroups in support of day-to-day plant operations. The issues encountered and the resource impacts of specific teamwork supporting practices adopted are outlined. (author)

2006-07-01

361

Construction Progress of the Cooling and Ventilation in the LHC Project  

CERN Document Server

The Cooling and Ventilation Group has started the LHC construction work in September 1999 and will get into full activity when LEP will be stopped and dismantled: in total 12 major contracts for an amount of about 120 MCHF will be established to build the needed installations for the LHC. The author will report on the current works that are in progress on the different LEP Points distinguishing between the Ventilation and the Water Cooling installations. The Ventilation work, completed in the new surface buildings in Points 18, is currently held in Points 4 and 5. Point 1 will follow in the near future. The work for the Cooling plants comprehend the pumping stations, the cooling towers and the chilled water production stations in Points 1 and 5, the buried pipes in Points 1 and 4. For all of these activities, an updated report of the progress of the work, of the planning and of the expenses is given. Finally, a short overview of the future ...

2001-01-01

362

Combined migration velocity model-building and its application in tunnel seismic prediction  

Science.gov (United States)

We propose a combined migration velocity analysis and imaging method based on Kirchhoff integral migration and reverse time migration, using the residual curvature analysis and layer stripping strategy to build the velocity model. This method improves the image resolution of Kirchhoff integral migration and reduces the computations of the reverse time migration. It combines the advantages of efficiency and accuracy of the two migration methods. Its application in tunnel seismic prediction shows good results. Numerical experiments show that the imaging results of reverse time migration are better than the imaging results of Kirchhoff integral migration in many aspects of tunnel prediction. Field data show that this method has efficient computations and can establish a reasonable velocity model and a high quality imaging section. Combination with geological information can make an accurate prediction of the front of the tunnel geological structure.

2010-09-01

363

An evaluation of the embedment of a Radio Frequency Integrated Circuit with a temperature detector in building envelopes for energy conservation  

British Library Electronic Table of Contents (United Kingdom)

Concrete is the primary material for building envelopes in some parts of the world, and its ability to store heat as well as its dynamic temperature changes will not only affect the deterioration rate of the exterior wall but will also greatly influence the energy efficiency of interior air conditioning. There are many methods for measuring the inner temperature of concrete, but they often have limitations, such as indirect estimation, cable installation requirements, high cost, or heterogeneity of the sample structure. In order to measure the internal temperature of concrete, this study integrated a Radio Frequency Integrated Circuit (RFIC) with a temperature sensor chip and embedded the device in concrete structures. A Smart Temperature Information Material (STIM) was thus developed. Thi...

2011-01-01

364

An authentication infrastructure for today and tomorrow  

Energy Technology Data Exchange (ETDEWEB)

The Open Software Foundation`s Distributed Computing Environment (OSF/DCE) was originally designed to provide a secure environment for distributed applications. By combining it with Kerberos Version 5 from MIT, it can be extended to provide network security as well. This combination can be used to build both an inter and intra organizational infrastructure while providing single sign-on for the user with overall improved security. The ESnet community of the Department of Energy is building just such an infrastructure. ESnet has modified these systems to improve their interoperability, while encouraging the developers to incorporate these changes and work more closely together to continue to improve the interoperability. The success of this infrastructure depends on its flexibility to meet the needs of many applications and network security requirements. The open nature of Kerberos, combined with the vendor support of OSF/DCE, provides the ...

1996-06-01

365

Advanced Neutron Source: Plant Design Requirements  

Energy Technology Data Exchange (ETDEWEB)

The Advanced Neutron Source will be a new world-class facility for research using hot, thermal, cold, and ultra-cold neutrons. The heart of the facility will be a 330-MW (fission), heavy-water cooled and heavy-water moderated reactor. The reactor will be housed in a central reactor building, with supporting equipment located in an adjoining reactor support building. An array of cold neutron guides will fan out into a large guide hall, housing about 30 neutron research stations. Appropriate office, laboratory, and shop facilities will be included to provide a complete facility for users. The ANS is scheduled to begin operation at the Oak Ridge National Laboratory early in the next decade. This PDR document defines the plant-level requirements for the design, construction, and operation of ANS. It also defines and provides input to the individual System Design Description (SDD) documents. Together, this PDR document and the set of SDD documents ...

1990-07-01

366

1981/82 nonresidential-building standards development project: economic assumptions for SOLFIN 2 analysis  

Energy Technology Data Exchange (ETDEWEB)

Documentation and use of various economic analysis tools, especially the SOLFIN 2, KRUNCH, LSAP, and SIPP computer programs, are provided. The report deals with the use of these tools to perform the social economic analysis which underlies building standards. A brief description of life-cycle cost methodology is presented. The documentation of SOLFIN 2 is included. Description of first cost calculations and life-cycle cost sensitivity analysis are given. A detailed account of the general description of how electricity costs are calculated is given in an appendix. Program listings for KRUNCH, SIPP, and LSAP are given in Appendix B. Fuel costs for low, medium, and high conservation scenarios are presented in Appendix C. (MCW)

1982-03-01

367

http-equiv=\\  

Wastenet

may be possible to meet those loads with renewable energy systems &mdashachieving zero-net- energy performance.Solar-thermal heating systems, ...p/p Spencer and others argue that renewable energy systems should be considered only after the building envelope ...energy loads are brought low enough, however, a renewable energy system may make sense financially. p

368

Ventilation intensity - Influence on the air quality and its calculation method; Die Lueftungsintensitaet - Auswirkung auf die Luftqualitaet und deren Berechnungsmethoden  

Energy Technology Data Exchange (ETDEWEB)

Because of good thermal insulation of advanced energetic buildings and their good airtightness the air hygiene is insufficient. A normal ventilation behaviour by window opening consumes too much heating energy. A calculation method is shown taking into account a required air change number, flow rate and indoor air quality as thermal comfort in the rooms occupied by different number of persons. (GL)

2006-07-01

369

Transient sheath overvoltages in armored power cables  

Energy Technology Data Exchange (ETDEWEB)

This paper is concerned with methods of limiting the build-up of transient voltages between sheath and armor in long armored power cables. Calculations by a frequency dependent cable model demonstrate that this voltage can be efficiently limited to an acceptable level by introducing sheath-armor bondings at regular intervals, or by using a semiconductive sheath-armor interlayer. The paper investigates the required minimum length between bondings, as well as the required conductivity of the sheath-armor interlayer if the use of bondings is to be avoided.

1996-07-01

370

Thermal performance of phase change wallboard for residential cooling application  

Energy Technology Data Exchange (ETDEWEB)

Cooling of residential California buildings contributes significantly to electrical consumption and peak power demand mainly due to very poor load factors in milder climates. Thermal mass can be utilized to reduce the peak-power demand, downsize the cooling systems, and/or switch to low-energy cooling sources. Large thermal storage devices have been used in the past to overcome the shortcomings of alternative cooling sources, or to avoid high demand charges. The manufacturing of phase change material (PCM) implemented in gypsum board, plaster or other wall-covering material, would permit the thermal storage to become part of the building structure. PCMs have two important advantages as storage media: they can offer an order-of-magnitude increase in thermal storage capacity, and their discharge is almost isothermal. This allows the storage of high amounts of energy without significantly changing the temperature of the room envelope. As heat ...

1997-04-01

371

The national nuclear material tracking system. A Korea's countermeasure against nuclear terrorism  

International Nuclear Information System (INIS)

Since nuclear terrorism has been identified as a real threat, the Korean government has earnestly developed elementary technologies and sub-systems for establishing an integrated defensive system against nuclear terrorism, which is based on the concept of defense-in-depth. This paper introduces the gist and implications of the studies that have been conducted in building the national nuclear material tracking system for preventing and intercepting the illicit trafficking and transporting of nuclear material in Korea. (orig.)

2011-07-01

372

The idea of a compton-collider  

Energy Technology Data Exchange (ETDEWEB)

A brief overview, from an experimentalist`s point of view, of the possibilities and difficulties involved in building a photon-photon collider using beams produced in Compton backscattering from a linear e{sup +}e{sup -} or e{sup -}e{sup -}collider. Some hindsight is included from the successful March 1994 Berkeley workshop on gamma-gamma colliders. (author). 13 refs., 2 figs.

1994-12-31

373

The idea of a compton-collider  

International Nuclear Information System (INIS)

A brief overview, from an experimentalist's point of view, of the possibilities and difficulties involved in building a photon-photon collider using beams produced in Compton backscattering from a linear e"+e"- or e"-e"-collider. Some hindsight is included from the successful March 1994 Berkeley workshop on gamma-gamma colliders. (author). 13 refs., 2 figs.

374

The European volcanic ash crisis: Between international and European law | EurActiv  

Wastenet

... Carbon capture and storage Waste Prevention and Recycling EU clean air strategy Environmental liability: Applying the 'polluter pays' principle What goes around ...comes around: Recycling and climate change Behind closed doors: Air quality in buildings Keeping cool with refrigerants: The F-gas review Regions fighting climate ...

375

Scalable digital libraries of event data and the NSCP meta-cluster  

Energy Technology Data Exchange (ETDEWEB)

In this paper we present the design, implementation, and experimental results of a system to mine and visualize event data using cluster computingbuilt upon an ATM network. Our approach is to build a system using light weight, modular software tools for data management, resource management, data analysis and visualization developed for local, campus and wide area clusters of workstations. (author)

1996-07-01

376

Sasol process technology - the challenge of synfuels from coal  

Energy Technology Data Exchange (ETDEWEB)

Description is given of how the design challenges were met in commissioning the Sasol Two plant in 1980, a larger plant than Sasol One, and devoted to producing liquid fuels. The design parameters included treating South African coals of poor quality with high ash contents, and rapidity in building the plant.

1986-08-01

377

Repowering and retrofits: building on past value  

Energy Technology Data Exchange (ETDEWEB)

Amidst the explosion of greenfield natural gas-fired combined-cycle plant development, opportunities still exist for valuable plant repowering and retrofits by taking advantages of unique technical and market conditions. One of the projects discussed is the rebuilding of the coal-fired Hawthorne unit 5 damaged by a boiler explosion. 3 tabs., 5 photos.

2000-01-01

378

Regulation about the technical environment of buildings: boiler-rooms / ventilation systems; RETA: chaufferies / ventilation  

Energy Technology Data Exchange (ETDEWEB)

This CD-Rom edited by the French scientific and technical committee of the space heating, ventilation and air-conditioning industry (CoSTIC) presents a series of technical files about ventilation and space heating systems with several references to the current regulatory texts. Modifications of the original legislative texts have been integrated to the original texts for a more comfortable reading. Search is performed using diagrams and key-words. (J.S.)

2000-06-01

379

Railways - EA BOOKS  

Wastenet

...91 ex-GST Terms and Conditions For 90 years they were the largest industrial workshops in the State, training tradesmen to build and repair locomotive engineers and rolling stock while maintaining the railway network. Display product Add to shopping basket Dow's Dictionary of Railway Quotations AU$43.59 ex-GST Terms and Conditions An authoritative compendium of quotations about railways from 1608 to the present day. Display product Add to shopping basket Railways and ...

380

Radon in the house construction. National and European policy; Radon in de woningbouw. Beleid op nationaal en Europees niveau  

Energy Technology Data Exchange (ETDEWEB)

Building materials contain low concentrations of natural radioactive materials, causing a radiation dose for occupants of houses. Governmental policies and regulations with respect to radon emission are or will be implemented. An overview is given of recent developments. 3 refs.

2000-03-01

381

Radon and radon daughter evaluation in a natural radioactivity survey indoors  

Energy Technology Data Exchange (ETDEWEB)

An indoor survey in order to estimate the population exposure in five towns of an Italian Region is presented. A particular methodology for the campaign was planned and is being applied. Gamma spectrometry of building materials, exposure rate measurements indoors and outdoors and radon concentration measurements indoors were taken with different techniques. A correlation was found between mean gamma exposure rate and mean radon concentration in the houses investigated. An evaluation of mean effective dose equivalents for the inhabitants of the five towns is reported.

1985-10-01

382

RTD Info 21 - Key Action  

Wastenet

... Targeted fields of research Continuation of ongoing research - Finalising detailed design work on the ITER project; getting JET operational at full power; Improvement of the basic concepts of fusion devices - Fusion plasmas; theoretical studies; technology watch on research into inertial confinement; new experimental concepts and systems; etc.; Long-term technology - Preparations for building a demonstration reactor (development of tritium breeding blankets; prospective ...

383

Quantum Cloning for Absolute Radiometry  

International Nuclear Information System (INIS)

In the quantum regime information can be copied with only a finite fidelity. This fidelity gradually increases to 1 as the system becomes classical. In this Letter we show how this fact can be used to directly measure the amount of radiated power. We demonstrate how these principles can be used to build a practical primary standard.

2010-08-20

384

Quality assurance requirements for nuclear power plants in Hungary  

International Nuclear Information System (INIS)

In Hungary, legislation for nuclear power plants was developed at the end of the 1970s, among which is the quality assurance code for nuclear power plants. Hungarian practice is presented, including discussion of the requirements for quality assurance, qualification of the suppliers and inspection practices. The general requirements of quality assurance in the course of construction of a nuclear power plant are presented: quality assurance of technological equipment, fuel, electrical equipment, automatic instrumentations, building structures and technology.

385

Pumped storage in the future power supply system  

Energy Technology Data Exchange (ETDEWEB)

Pumped storage plants (PSP) supply up to several GW of power and several ten GWh of capacity. Short start-up times and low start-up costs predestine PSP for the control energy market. Grid charges for PSP endanger the further integration of renewable energy and lead to higher electricity supply costs. Therefore, an amendment of legislation is urgently required. Requirements for building large PSP are met at numerous sites in the low mountain ranges of Germany. (orig.)

2010-07-01

386

Population exposure to external natural radiation background in the United States  

Energy Technology Data Exchange (ETDEWEB)

This report revises estimates of population exposure to external natural background made by D. T. Oakley in 1972. The revisions include more recent estimates of dose equivalents from cosmic rays, use of 1970 U.S. census data, and corrections for building shielding and for self-shielding in the body. The dose equivalents calculated are those from cosmic rays and terrestrial radiation, and do not include doses from natural radioactive materials in the body.

1981-04-01

387

New approach to the design of LMFBR liners  

Energy Technology Data Exchange (ETDEWEB)

The reconstruction of steel lining of the FFTF reactor building is described. The cold part of the lining has a simple structure and represents a steel sheet of 6.35 mm thickness welded to I-shaped imbedded in concrete, the hot part is meant for resisting the hot sodium contacting with it. The reconstruction has been reduced to the substitution of usual lining, the sheets of which are fixed in such a way that dangerous strains in metal arising at evaporation are excluded by the new structure admitting sheet deformation.

1981-01-01

388

National Renewable Energy Laboratory 2005 Research Review  

Energy Technology Data Exchange (ETDEWEB)

Science and technology are at the heart of everything we do at the National Renewable Energy Laboratory, as we pursue innovative, robust, and sustainable ways to produce energy--and as we seek to understand and illuminate the physics, chemistry, biology, and engineering behind alternative energy technologies. This year's Research Review highlights the Lab's work in the areas of alternatives fuels and vehicles, high-performing commercial buildings, and high-efficiency inverted, semi-mismatched solar cells.

2006-06-01

389

NAME=\\  

Wastenet

... The structure comprises piled foundations supporting a steel frame, and is clad in both masonry and rainscreen cladding systems. The hotel is adjacent to the recently redeveloped bus station in the centre of Norwich. Related Services Structural Design Go View all Services Find Projects Sector All Sectors Buildings & Infrastructure Environment Natural Resources Transportation Sub Sector All Sub-Sectors Country All Countries Angola Antigua and Barbuda Argentina ...

390

NAME=\\  

Wastenet

... Further complications resulted from the requirement to use existing piled foundations and columns which had originally been designed to accommodate a six-storey office block. The hotel bedroom configurations and planning constraints were different from thos Related Services Structural Design Go View all Services Find Projects Sector All Sectors Buildings & Infrastructure Environment Natural Resources Transportation Sub Sector All Sub-Sectors Country All Countries Angola Antigua and Barbuda Argentina Australia Azerbaijan ...

391

Markets for clean energy  

Wastenet

... The products can be categorised as glazed flat-plate collectors, evacuated glass-tube collectors, and unglazed plastic or low temperature collectors. Glazed flat-plate collectors and vacuum tubes are widely used for solar water heating and space heating systems in all types of buildings. Unglazed plastic collectors are used exclusively for lower temperature applications, such as outdoor swimming pools or the agrarian business. Flat-plate solar collectors are likely to ...

392

Low temperature heating systems. More comfort with less energy; Lage temperatuursystemen. Meer comfort met minder energie  

Energy Technology Data Exchange (ETDEWEB)

To realise the Dutch objectives of energy saving and emission reductions in the built environment, the use of 'Low Valued Energy' will be necessary in the future. Low Valued Energy is available from residual, ambient heat and renewable sources. Using Low Valued Energy for space heating in commercial and residential buildings requires adjusting the design of the installations, i.e. lowering the design supply temperature of the heating system from 90C to 55C or less. Appropriate heat distribution systems, e.g. floor or wall heating and radiators, have a life cycle of 40 to 50 years. The application (on a large scale in buildings), however, requires an enormous change in the installation and building branch. To enable the application of low temperature sources in the future, the building and installation designs should be based on low temperature distribution systems. Being aware of this ...

2000-06-01

393

Laser weapons. II - Strategic laser weapons  

Science.gov (United States)

Potential strategic missions for laser weapons, particularly those involving space-based lasers, are discussed. The functions of space-based lasers and the history of their conceptual development are summarized, and the problems of implementing such systems, including the building of a suitable laser and power source, and resolving the problem of optics, are discussed. Ongoing development programs are described, and the contrasting views of the necessity and usefulness of strategic laser systems are set forth.

1982-07-01

394

Japan Groundwork Association to aid disaster support effort  

Wastenet

...six months Organising local tours of the area for up to 1000 affected families in the Izu Penninsula area around Mount Fuji Mobile food stalls that wlll serve up to 10,000 bottles of water and 10,000 servings of food Mobile human waste disposal units Building northern Japan support committees Browser does not support script. Browser does not support script. For further information, please contact: Garry Campbell, PR & ...

395

Interim safety basis for fuel supply shutdown facility  

Energy Technology Data Exchange (ETDEWEB)

This ISB in conjunction with the new TSRs, will provide the required basis for interim operation or restrictions on interim operations and administrative controls for the Facility until a SAR is prepared in accordance with the new requirements. It is concluded that the risk associated with the current operational mode of the Facility, uranium closure, clean up, and transition activities required for permanent closure, are within Risk Acceptance Guidelines. The Facility is classified as a Moderate Hazard Facility because of the potential for an unmitigated fire associated with the uranium storage buildings.

1995-05-23

396

Incorporation of "1"4C-linoleic acid in cerebrosides of psoriatic and normal human skin  

International Nuclear Information System (INIS)

It was shown that the incorporation of "1"4C-linoleic acid in cerebrosides of normal and psoriatic human skin is different. In psoriatic epidermis and corium the turnover of this fatty acid is significantly elevated. It is suggested that in psoriasis the epidermal cell is not able to build up a regular carbohydrate sequences of lipids because the false carbohydrate chain activates the degradation of glycolipids and in compensating for the increased degradation raises the synthesis rate of glycolipids. (orig./MG).

397

High air quality and low energy consumption. Performance of hybrid ventilation with CO2-sensors; Hoge luchtkwaliteit en lage energiebesparing. Goede prestaties van hybride ventilatie met CO2-sensoren  

Energy Technology Data Exchange (ETDEWEB)

The school building complex Waterland in The Hague, Netherlands, was built with a hybrid ventilation system. The indoor environment and energy consumption were monitored for one year. Air quality and thermal comfort are of a high quality and the consumption of energy for heating is circa 35% lower than normal. The Waterland project was one of eight demonstration projects, carried out within the framework of the ECBS-Annex 35: Hybrid ventilation in New and retrofitted Office Buildings. ECBS stands for the IEA-program Energy Conservation in Buildings and Community Systems. [Dutch] In ECBCs-annex 35 (ECBS staat voor het IEA-programma Energy Conservation in Buildings and Community Systems) is uitgebreid onderzoek gedaan naar hybride ventilatiesystemen in kantoren en scholen. Dit project heeft geleid tot acht internationale voorbeeldprojecten, waarvan scholencomplex Waterland te Den Haag er een van is. Het ...

2005-11-01

398

Global quantum gauge symmetry via reconstruction theorems  

Energy Technology Data Exchange (ETDEWEB)

In this paper we establish that every quantum field theory satisfying some basic axioms possesses a weak quasi Hopf algebra as gauge symmetry. We use a reconstruction theorem to find this symmetry algebra and show how it is sed to build a gauge covariant field algebra. We investigate the question of why this generality is necessary. The non-uniqueness of the reconstruction process is interpreted and a cohomological classification of possible global gauge symmetries is given. (author)

1996-12-21

399

Geothermal heat pumps - gaining ground in the UK and worldwide  

Energy Technology Data Exchange (ETDEWEB)

This 2001 edition of the guide to UK renewable energy companies examines the geothermal heat pump sector, and discusses the technology involved, installations of geothermal heat pumps, the activity in the UK market with increased interest in UK geothermal heat pump products from abroad, and developments in the building sector. The UK government's increased support for the industry including its sponsorship of the Affordable Warmth programme, and the future potential of ground source systems are discussed.

2001-07-01

400

Geothermal heat pumps - gaining ground in the UK and worldwide  

International Nuclear Information System (INIS)

This 2001 edition of the guide to UK renewable energy companies examines the geothermal heat pump sector, and discusses the technology involved, installations of geothermal heat pumps, the activity in the UK market with increased interest in UK geothermal heat pump products from abroad, and developments in the building sector. The UK government's increased support for the industry including its sponsorship of the Affordable Warmth programme, and the future potential of ground source systems are discussed.

401

Far East combined-cycle update  

Energy Technology Data Exchange (ETDEWEB)

Korea Electric Power Corporation (Kepco) of South Korea has awarded Asea Brown Boveri Switzerland, a member of the ABB Group, a contract to supply the main equipment for two gas-fired combined-cycle power stations. News of the contract followed an announcement last year that Kepco will build a series of gas-fired power stations in the early 1990s to supply electricity to new housing and commercial areas being built in the Seoul-Incheon connurbation. (author).

1991-03-01

402

Experience with protection and restoration measures on reinforced concrete structures; Erfahrungen mit Schutz- und Instandsetzungsmassnahmen an Stahlbeton-Konstruktionen  

Energy Technology Data Exchange (ETDEWEB)

Often measures of protection and restoration of reinforced concrete structures are not taken until damage occurs which affects power plant operation. These failures can be avoided by predictive civil engineering maintenance and repair. The consequent application and implementation of a life-time management system for power plant buildings is being suggested. (orig.)

2008-07-01

403

Evaluation of indoor and outdoor climate on sites polluted with volatile organic chemicals  

International Nuclear Information System (INIS)

Papers presented at a meeting on indoor and outdoor climates on sites polluted with volatile organic chemicals. The papers deal with the subject of evaporation of organic chemicals on the polluted sites in relation to the influence on indoor and outdoor climates. Themes dealt with are diffusion through soils and transport of pollutants from the soil into buildings. (AB).

1993-11-04

404

Downward penetration of hot UO/sub 2/ into basalt concrete  

Energy Technology Data Exchange (ETDEWEB)

Following a postulated meltdown accident, the integrity of containment building structural material under attack by hot molten core debris and the safeguard of environment against radiological releases constitutes the final line of defense in PAHR safety assessment. Such assessment requires a good knowledge of UO/sub 2//interaction and penetration with different types of concrete. The present study focuses on the phenomena associated with core debris interaction/penetration with substrate basalt concrete.

1983-01-01

405

Development of High-Efficiency Low-Lift Vapor Compression System - Final Report  

Energy Technology Data Exchange (ETDEWEB)

PNNL, with cofunding from the Bonneville Power Administration (BPA) and Building Technologies Program, conducted a research and development activity targeted at addressing the energy efficiency goals targeted in the BPA roadmap. PNNL investigated an integrated heating, ventilation and air conditioning (HVAC) system option referred to as the low-lift cooling system that potentially offers an increase in HVAC energy performance relative to ASHRAE Standard 90.1-2004.

2010-03-31

406

Demonstrating leadership inside and out : green building project trains employees, educates clients  

Energy Technology Data Exchange (ETDEWEB)

This article described a full-scale green renovation project undertaken by a construction management firm in Newton, Massachusetts. Chapman Construction and Design began renovating its own office building in late 2007 and completed it in September 2008. The firm set out to achieve LEED Platinum certification from the United States Green Building Council. The project involved energy saving modifications to its mechanical systems; replacing plumbing fixtures with high efficiency alternatives to reduce water consumption by at least 40 per cent; installing skylights and additional windows to allow more natural light into the interior space; salvaging doors, lighting, metal studs and masonry whenever possible; and using sustainable products such as recyclable carpets, tiles and low-VOC paint. The main feature of the renovation was a new 47 kW (DC) photovoltaic (PV) solar power array installed on the rooftop. The PV array includes 208 panels and a ...

2009-01-15

407

Daylighting design tool survey  

Energy Technology Data Exchange (ETDEWEB)

Design tools that are currently available for use with microcomputers to assist in designing energy-efficient daylighted buildings are presented. The information presented was gathered as a part of a telephone survey to design tool developer conducted over a six month period. The matrix is but one of five categories of tools. The other four were nomographs, protractors/tables, minis, and main frame computer programs. Information is provided to encourage interested design professionals, educators and students to communicate directly with design tool representatives.

1986-01-01

408

Data Center Energy Benchmarking: Part 4 - Case Study on aComputer-testing Center (No. 21)  

Energy Technology Data Exchange (ETDEWEB)

The data center in this study had a total floor area of 8,580 square feet (ft{sup 2}) with one-foot raised-floors. It was a rack lab with 440 racks, and was located in a 208,240 ft{sup 2} multi-story office building in San Jose, California. Since the data center was used only for testing equipment, it was not configured as a critical facility in terms of electrical and cooling supply. It did not have a dedicated chiller system but served by the main building chiller plant and make-up air system. Additionally, it was served by a single electrical supply with no provision for backup power. The data center operated on a 24 hour per day, year-round cycle, and users had all hour full access to the data center facility. The study found that data center computer load accounted for 23% of the overall building electrical load, while the total power consumption attributable to the data center including allocated cooling load and ...

2007-08-01

409

Current ventilation and air conditioning systems and strategies  

Energy Technology Data Exchange (ETDEWEB)

The report examines common ventilation and air conditioning systems and strategies for both domestic and commercial buildings; and covers issues such as energy conservation, indoor air quality and occupant comfort. Drawing data from many countries in Europe and the United States of America, various natural, mechanical and air conditioning systems were compared using criteria such as climate, level of occupant interaction, and level of system comfort. This classification system is evaluated and seen as a valuable framework for further research. (U.K.)

1994-02-01

410

Crumbling case for nuclear power  

Energy Technology Data Exchange (ETDEWEB)

In connection with the Public Inquiry into the CEGB proposal to build a pressurised water reactor at Sizewell in Suffolk, the case for nuclear power is examined under the headings: the economics of nuclear power - how they would like them to be; systems analysis - net effective cost; CEGB prejudices the results (comparison with coal-fired plants; forecasting on various assumptions); discounting future costs; back-end costs soar (reprocessing); real reprocessing costs; AGR costs balloon.

1983-01-01

411

Criticality safety review of FFTF interim decay storage tank  

Science.gov (United States)

The Interim Decay Storage tank (IDS) will be located in a concrete cell in the FFTF reactor building. The tank will have capacity to store 112 driver fuel assemblies and 10 test assemblies in sodium. A criticality safety analysis for the design of the IDS tank was performed. From the analysis, it is concluded that under normal operating conditions and minor abnormal conditions that might shift the fuel, the IDS tank will remain adequately subcritical. (auth)

1975-10-01

412

Concept of Plasma Spraying System for Solid Oxide Fuel Cell: Heating Studies of YSZ Particle in Plasma Jet  

International Nuclear Information System (INIS)

One of several methods to build YSZ electrolyte of SOFC is plasma spraying. This system heats particle to a melting point and then pushing them into target and forming a deposition. This paper presents heating studies of YSZ particle in plasma jet. By simple model it is shown that the required time such those YSZ particle with grain size of 50 ?m to be melt is around 12 x 10-4 second. (author)

2006-07-01

413

Complaints about the indoor environment; Klachten over het binnenmilieu  

Energy Technology Data Exchange (ETDEWEB)

An overview is given of techniques to analyze all kinds of complaints from occupants of office buildings about their working environment: headaches, lethargy, eye irritation, respiratory problems, and complaints about the temperature and draught. Special attention is paid to the sensory evaluation of air quality. 4 figs., 7 refs.

1995-04-01

414

Cold regions hydrology and hydraulics  

Energy Technology Data Exchange (ETDEWEB)

This monograph addresses a narrow aspect of cold regions engineering, namely the effects of cold weather on the traditional civil engineering disciplines of hydrology and hydraulics. Hydrologic and hydraulic considerations in the design, construction, and operation of civil works are very important. Many of the problems encountered in the design and construction of buildings, transportation systems, water supply facilities, waste treatment facilities, and hazardous waste disposal facilities, for example are closely tied to the characteristics of the site hydrology.

1990-01-01

415

Choice of energy data in environmental assessment of the built environment  

Energy Technology Data Exchange (ETDEWEB)

Life cycle oriented methods are increasingly used for environmental assessments (EAs) of the built environment. However, many assumptions are made in such assessments, potentially influencing the results and making the assessment more ambiguous. To increase the reliability of EAs, consequences of the assumptions made have to be better understood. Since energy use in the operation and maintenance phase is an important factor decisive for the overall environmental performance of a building, the purpose of this study is to investigate how the selection of heat and electricity mix affects the assessed environmental performance of buildings. It also aims to suggest how to choose heat and electricity data in EAs of the built environment in general. Applying four different modes of electricity production and two different modes of heat production in a case study of three different buildings with different technical solutions for ...

2003-03-01

416

Case for Sizewell B  

Energy Technology Data Exchange (ETDEWEB)

A review and a number of extracts are given of the statement made by the acting chairman of the CEGB at a press conference on the publication of documents in support of the case for the building of the proposed Sizewell B PWR. The documents comprise the CEGB Statement of Case proper, the Reference Design, the Pre-Construction Safety Report and some 300 supporting reports. Objectors have eight months to study the reports before the public inquiry into the CEGB's proposals due to open in January 1983.

1982-07-01

417

Building a sustainable energy system  

Energy Technology Data Exchange (ETDEWEB)

The inevitability of sustainable economic development and its linkage to a gradual shift to renewable energy sources, especially solar energy, was discussed. Means to measure sustainability of technology were described, and policy instruments (essentially research, development and demonstration, and punitive taxes on conventional energy carriers) to accelerate the shift to renewable energy sources were outlined.

1995-12-31

418

Britain's first pressurised-water reactor  

Energy Technology Data Exchange (ETDEWEB)

The recent announcement that the public inquiry into the CEGB's plans to build a PWR at Sizewell will begin in January 1983 and the statement which followed from the task force that was set up in July 1981 to consider the future of the PWR programme in the UK, are considered. The relevant time scales, costs and safety, in particular the cost incurred due to the added safety features for the British PWR, are discussed. The effect of political aspects on the future of the PWR in Britain is considered.

1982-01-28

419

Big is beautiful in biotechnology  

Energy Technology Data Exchange (ETDEWEB)

Venture capital has guaranteed the successful launch of biotechnology in the US since 1977. Established companies are then licensed to produce and distribute the latest inventions. By contrast in Japan established industrial companies are the leaders in biotechnology research, development and commercialization, building on existing technology and past experience and retraining staff. In the US electronics industry the acute shortage of electronic engineers combined with the high cost of capital and instability within venture capital companies to restrict the high level of innovation required looks likely to happen again in biotechnology.

1984-01-01

420

Atlas of room air flow; Raumstroemungsatlas  

Energy Technology Data Exchange (ETDEWEB)

Within the framework of the IEA project Annex 20 - Airflow patters within buildings , an airflow data base was built up as a prototype. It enables airflow profiles, comfort and interior air quality to be studied without having to carry out a 1:1 experiment or having to run an expensive simulation code. The data base contains a number of pre-calculated room airflow profiles with their associated depictions of air quality and risks of drafts for given premises and for different ventilation systems. figs., tabs., refs.

1994-12-31

421

Asilomar conference on managing complexity in high energy physics: A summary and renaming of the conference  

Energy Technology Data Exchange (ETDEWEB)

The complex aspects of high energy physics work are briefly described, and approaches to managing them are discussed. Management of software and data are covered. For managing complexity in experimental physics, the choice of building or buying processor systems is addressed and the issues of compatibility and standardization are discussed. (LEW)

1987-02-01

422

Architectural design for reliability  

Energy Technology Data Exchange (ETDEWEB)

Design-for-reliability concepts can be applied to the products of the construction industry, which includes buildings, bridges, transportation systems, dams, and other structures. The application of a systems approach to designing in reliability emphasizes the importance of incorporating uncertainty in the analyses, the benefits of optimization analyses, and the importance of integrating reliability, safety, and security. 4 refs., 3 figs.

1997-08-01

423

An overview of issues in developing industrial data mining and knowledge discovery applications  

Energy Technology Data Exchange (ETDEWEB)

This paper surveys the growing number of industrial applications of data mining and knowledge discovery. We look at the existing tools, describe some representative applications, and discuss the major issues and problems for building and deploying successful applications and their adoption by business users. Finally, we examine how to assess the potential of a knowledge discovery application.

1996-12-31

424

An architecture for device independent interfacing  

Energy Technology Data Exchange (ETDEWEB)

Achieving device independence for software applications is required for all but a small number of critical real time applications. Device independence is achieved by establishing protocols and building protocol interpreters for the specific devices. Data structures containing pointers to functions provide a flexible architecture for implementing protocol translation. 3 refs., 5 figs.

1990-01-01

425

A promising 2 GW turboset for nuclear power plants  

International Nuclear Information System (INIS)

In co-operation with the Scientific Planning Department of the Central Research Institute for Vessel- and Turbine Building the construction office of the turbine factory Charkow finished the draft of a slowly running (n = 1500 min"-"1) 2 GW-turboset for the operation of nuclear power plants. The chief purpose of the project was to determine the technical problems that are used to occur during the development of such steam turbines, as well as to settle the most favourable design. (orig./GL).

426

Data Center Energy Benchmarking: Part 3 - Case Study on an ITEquipment-testing Center (No. 20)  

Energy Technology Data Exchange (ETDEWEB)

The data center in this study had a total floor area of 3,024 square feet (ft{sup 2}) with one-foot raised-floors. It was a rack lab with 147 racks, and was located in a 96,000 ft{sup 2} multi-story office building in San Jose, California. Since the data center was used only for testing equipment, it was not configured as a critical facility in terms of electrical and cooling supply. It did not have a dedicated chiller system but was served by the main building chiller plant and make-up air system. Additionally it was served by only a single electrical supply with no provision for backup power in the event of a power outage. The Data Center operated on a 24 hour per day, year-round cycle, and users had full-hour access to the data center facility. The study found that data center computer load accounted for 15% of the overall building electrical load, while the total power consumption attributable to the data center ...

2007-07-01

427

Funding programme ``30 low energy buildings in Hesse`` - experience and conclusion; Foerderprogramm `30 Niedrigenergiehaeuser in Hessen` - Erfahrungen und Schlussfolgerungen  

Energy Technology Data Exchange (ETDEWEB)

Low energy buildings promise significant energy savings and help climate preservation by cutting down on annual heating requirements to values below 70 kWh per m{sup 2} dwelling space. It is expected that low energy constructions will become the common standard by the year 2000 as a result of the forthcoming energy saving ordinance. For making the introduction and implementation of this standard successful, practical experience will be essential. For this reason, the state government of Hesse has supported respective pilot projects 1987. In 1989 the funding programme `30 low energy buildings in Hesse` has been established. Consecutively - between 1989 and 1993 - 29 buildings were erected. At first, the thermal quality of the crafted building construction including the ventilation systems was checked. Consecutively, energy consumption, indoor and outdoor temperatures were measured over a time span of ...

1998-10-01

428

Waste Handeling Building Conceptual Study  

Energy Technology Data Exchange (ETDEWEB)

The objective of the ''Waste Handling Building Conceptual Study'' is to develop proposed design requirements for the repository Waste Handling System in sufficient detail to allow the surface facility design to proceed to the License Application effort if the proposed requirements are approved by DOE. Proposed requirements were developed to further refine waste handling facility performance characteristics and design constraints with an emphasis on supporting modular construction, minimizing fuel inventory, and optimizing facility maintainability and dry handling operations. To meet this objective, this study attempts to provide an alternative design to the Site Recommendation design that is flexible, simple, reliable, and can be constructed in phases. The design concept will be input to the ''Modular Design/Construction and Operation Options Report'', which will address the overall program ...

2000-11-06

429

Verification of maximum impact force for interim storage cask for the Fast Flux Testing Facility  

Energy Technology Data Exchange (ETDEWEB)

The objective of this paper is to perform an impact analysis of the Interim Storage Cask (ISC) of the Fast Flux Test Facility (FFTF) for a 4-ft end drop. The ISC is a concrete cask used to store spent nuclear fuels. The analysis is to justify the impact force calculated by General Atomics (General Atomics, 1994) using the ILMOD computer code. ILMOD determines the maximum force developed by the concrete crushing which occurs when the drop energy has been absorbed. The maximum force, multiplied by the dynamic load factor (DLF), was used to determine the maximum g-level on the cask during a 4-ft end drop accident onto the heavily reinforced FFTF Reactor Service Building`s concrete surface. For the analysis, this surface was assumed to be unyielding and the cask absorbed all the drop energy. This conservative assumption simplified the modeling used to qualify the cask`s structural integrity for this accident condition.

1996-06-01

430

The use of calcium silicate bricks for retrospective dosimetry  

International Nuclear Information System (INIS)

The suitability of calcium silicate bricks (CSBs) for the retrospective measurement of gamma dose using luminescence techniques has been investigated. Bricks of this type are distinguished from fired clay bricks by containing negligible clay and requiring comparatively low temperature treatment during manufacture. They have been used widely in the construction f buildings in the Former Soviet Union since the 1970s but hitherto have not been used for retrospective dosimetry measurements. A procedure based on the se of the 210 deg. C thermoluminescence (TL) peak of quartz was tested with granular quartz extracted from three types of CSB, one of which had been taken from a settlement downwind of Chernobyl. The degree to which the residual geological TL signal within the temperature range of the 210 deg. C L peak had been reduced during manufacture varied with brick type; the levels of residual TL corresponded, in the samples tested, to absorbed doses n the range ...

2004-02-01

431

The indoor environment and advanced ventilation systems; Binnenmilieu steeds afhankelijker van geavanceerde ventilatie  

Energy Technology Data Exchange (ETDEWEB)

A lower energy efficiency standard for buildings (EPC) can have a negative impact on thermal comfort and indoor air quality. Cooperation and integrated design are preconditions for a correct use, installation and maintenance of heating and ventilation systems in buildings. [Dutch] Er komt steeds meer kritiek op de wijze waarop in ons land woningen en gebouwen worden gebouwd. Op dit moment is het vooral woonhuisventilatie waar veel om te doen is. Van beleidsmakers tot aannemers en van Consumentenbond tot gezondheidsdiensten; iedereen vraagt zich af of we met vergaande isolatie onze woningen en gebouwen nog wel leefbaar houden. In dit artikel wordt een pleidooi gehouden voor onderlinge samenwerking en integraal ontwerp als randvoorwaarden voor een goede toepassing, installatie en onderhoud van verwarmings- en ventilatiesystemen in gebouwen.

2006-09-15

432

The RADionuclide transport, removal, and dose (RADTRAD) code  

International Nuclear Information System (INIS)

The RADionuclide Transport, Removal, And Dose (RAD-TRAD) code is designed for U.S. Nuclear Regulatory Commission (USNRC) use to calculate the radiological consequences to the off-site population and to control room operators following a design-basis accident at light water reactor (LWR) power plants. This code utilizes updated reactor accident source terms published in draft NUREG-1465. The code will track the transport of radionuclides as they are released from the reactor pressure vessel, travel through the primary containment and other buildings, and are released to the environment. As the radioactive material is transported through the primary containment and other buildings, credit for several removal mechanisms may be taken, including sprays, suppression pools, overlying pools, filters, and natural deposition. Simple models are available for these different removal mechanisms that use, as input, information about the conditions in the ...

1993-11-14

433

The RADionuclide Transport, Removal, and Dose (RADTRAD) code  

Energy Technology Data Exchange (ETDEWEB)

The RADionuclide Transport, Removal, And Dose (RADTRAD) code is designed for US Nuclear Regulatory Commission (USNRC) use to calculate the radiological consequences to the offsite population and to control room operators following a design-basis accident at Light Water Reactor (LWR) power plants. This code utilizes updated reactor accident source terms published in draft NUREG-1465, ``Accident Source Terms for Light-Water Nuclear Power Plants.`` The code will track the transport of radionuclides as they are released from the reactor pressure vessel, travel through the primary containment and other buildings, and are released to the environment. As the radioactive material is transported through the primary containment and other buildings, credit for several removal mechanisms may be taken including sprays, suppression pools, overlying pools, filters, and natural deposition. Simple models are available for these different removal mechanisms that ...

1993-07-01

434

Space HVAC engineering 2003. Part 1. An overview; Die Luft- und Klimatechnik 2003. Teil 1. Eine Bestandsaufnahme  

Energy Technology Data Exchange (ETDEWEB)

The development of the space HVAC sector during the past 25 years is reviewed. It is shown how the importance of room climate has increased, as illustrated, e.g., by the concepts of 'thermal comfort', 'comfort', and 'sick building syndrome'. A sequel will be published in the next issue of KK. (orig.) [German] Der folgende Beitrag ist eine Bestandsaufnahme im Hinblick auf technologische Entwicklungen in der Klima- und Lueftungstechnik der letzten 25 Jahre, ein Zeitraum in dem sich einiges veraendert hat. Gleichzeitig wird deutlich, welcher Wandel sich bei der Bedeutung des Raumklimas in Gebaeuden vollzogen hat, indem beispielsweise Begriffe wie ''Behaglichkeit'', ''Komfort'' aber auch ''Sick Building Syndrom'' eine immer groessere Rolle spiel(t)en. Die Fortsetzung in der naechsten ...

2003-03-01

435

Results of surface activity and radiation field measurements made during surface decontamination experiments conducted at TMI-2  

International Nuclear Information System (INIS)

The Gross Decontamination Experiment was conducted on various levels and surfaces of the TMI-2 Reactor Building during February and March 1982 and was designed to investigate the effectiveness of various surface decontamination techniques. The polar crane, D-rings, missile shields, refueling canal, fueling bridge, major equipment, floors and some walls were flushed with low pressure water. Water lances were directed manually and applied water at temperatures between ambient and 60"0C at a flow rate of about 95 liters per minute. In addition, floor surfaces on the 305-ft elevation and floor surfaces and major equipment on the 347-ft elevation were sprayed with high pressure water (floors in the Reactor Building are designated by their elevations above sea level). The water pressure in this case varied between 13.8 and 41.4 mPa and water temperature was at a maximum 60"0C. Certain surfaces were also decontaminated using either strippable coatings ...

1984-07-15

436

Re-evaluation of floor response spectra of reactor building for Daya Bay NPP  

International Nuclear Information System (INIS)

The seismic analysis of nuclear island of Daya Bay Nuclear Power Plant (NPP) was just in accordance with the approaches in RCC-G standard for the model M310 in France, in which the simplified impedance matrix method was employed for the consideration of soil's function. In this paper the more sophisticated 3D half-space continuum impedance method based on the Green functions is used to analyze the function of soil. In addition, multi-group of input time histories was used in the seismic response analysis in the existing design and their average of responses for each group was taken as the design basis. The same multi-group of input time histories was used in the seismic response analysis in this study, but the average and enveloped value of responses for each case are calculated respectively to account for the uncertainty of input motions. Focused on the above two issues, the seismic responses of the reactor building are calculated and the floor response spectra ...

2006-03-01

437

Power plants 2010. Lectures  

International Nuclear Information System (INIS)

The proceedings include the following lectures: Facing the challenges - new structures for electricity production. Renewable energies in Europe - chances and challenges. Nuclear outlook in the UK. Sustainable energy for Europe. Requirements of the market and the grid operator at the electricity production companies. Perspectives for the future energy production. Pumped storage plants - status and perspectives. Nuclear power/renewable energies -partners or opponents? New fossil fired power stations in Europe - status and perspectives. Nuclear energy: outlook for new build and lifetime extension in Europe. Biomass in the future European energy market - experiences for dong energy. Meeting the EU 20:20 renewable energy targets: the offshore challenges. DESERTEC: sustainable electricity for Europe, Middle East and North Africa. New power plants in Europe - a challenge for project and quality management. Consideration of safely in new build ...

2010-09-22

438

Modelling discharges in electronegative gases  

Energy Technology Data Exchange (ETDEWEB)

This paper builds on earlier work to give a consistent treatment of the positive column of discharges in electronegative gases covering the transition from collisionless to collisional. In particular it seeks to elucidate the conditions under which there is an ion-ion plasma core surrounded by an electron-ion plasma, and when there is not. The parameters which describe the processes of ionization, attachment, detachment and recombination are related to the central negative ion density relative to the electron density and, where appropriate, the size of the core. The use, by earlier workers, of the Boltzmann approximation to describe the negative ion distribution and to obtain ambipolar diffusion coefficients at higher pressures is shown not to be justified. This leads to the clarification of an inconsistency in the literature. Where possible, the work is related to other recent treatments of the same problem in order to begin to build a ...

1999-09-07

439

Heating and ventilation concept for a better room climate and for energy conservation. Part 1; Heiz- und Lueftungskonzept fuer besseres Raumklima und Energieeinsparung. T. 1  

Energy Technology Data Exchange (ETDEWEB)

Ventilation, cooling and illumination of modern high-rise office buildings with high-quality thermal insulation (average k-value 1.0 W/m12K) and high loads from office machinery (up to 20 W/m12 and beyond) are problematic even for modern facility management systems, with consequences for the building shell, heating system, and window ventilation. [Deutsch] Die Lueftung, Kuehlung und Beleuchtung moderner Buerohochbauten mit extremer Waermedaemmung (mittlerer K-Wert 1,0 W/m{sup 2}K) und hohen Bueromaschinenlasten (bis zu 20 W/m{sup 2} und mehr) verursachen auch heute noch erhebliche Probleme, obwohl die technische Gebaeudeausruestung weiterentwickelt wurde. Dies zeigt sich vor allem bei der Fassadenausbildung der Heizung und Fensterlueftung. (orig.)

1999-11-01

440

Heating and cooling with geothermal energy: trends and accomplishments; Solutions de chauffage et de climatisation utilisant l`energie geothermique: tendances et realisations  

Energy Technology Data Exchange (ETDEWEB)

Recent developments in heat pump technology have made geothermal-based heat exchange systems particularly well-suited for the heating and cooling needs of buildings even in cold climates. The principles of geothermally-coupled heat pump heating and cooling systems were presented. Results of an in-situ study conducted by Hydro-Quebec on the efficiency of the geothermal heat pump system installed at the Saint-Hyacinthe professional school were summarized. This investigation was meant to be a case study of the applicability of these new technologies to the needs of the Quebec market. After the first year of service, the Saint-Hyacinthe system clearly demonstrated its cost effectiveness over conventional systems. It was predicted that geothermal heat pump systems will gain in popularity in Quebec because they can fully meet the heating and cooling needs of public buildings at considerable cost reductions, besides offering considerable environmental ...

1996-03-01

441

Heat pumps in urban space heating systems: Energy and environmental aspects  

International Nuclear Information System (INIS)

A statistical survey is conducted of air pollution in the city of Rome (Italy) due to conventional building space heating systems burning fossil fuels. The survey identifies the annual consumption of the different fuels and the relative amounts of the various pollutants released into the atmosphere by the heating plants, e.g., sulfur and nitrogen oxides, carbon monoxide, etc. Comparisons are then made between the ratios of urban heating plant air pollutants produced per tonne of fuel employed and those for ENEL (Italian National Electricity Board) coal, oil and natural gas fired power plants, in order to demonstrate the better environmental performances of the utility operated energy plants. The building space heating system energy consumption and pollution data are then used in a cost benefit analysis favouring the retrofitting of conventional heating systems with heat pump systems to obtain substantial reductions in energy consumption, ...

1991-01-01

442

Full autonomous monitoring tools inside nuclear reactor building  

Energy Technology Data Exchange (ETDEWEB)

In this paper, we define, design and test a radiation tolerant autonomous monitoring tool for nuclear embedded applications. The goal of the instrumentation system was to record the values of some parameters such as dose, temperature or vibrations appearing inside the containment building of nuclear power plants. The knowledge of these parameters will be a good help for predictive maintenance of the power plant components. For the design of the monitoring tool, we rely on commercial-off-the-shelf (COTS) low power electronic components to use battery-supplied power. A large amount of components starting from discrete transistors or logic units to memories and micro-controllers was associated to define and design a prototype. We then confirm the environment conditions tolerance estimated to up to 2 kGy of total dose and 80 C for temperature by on-line irradiation experiments for individual components and functions and prototypes. Two different sets of about 60 ...

2009-07-01

443

Fuel storage basin seismic analysis  

International Nuclear Information System (INIS)

The 105-KE and 105-KW Fuel Storage Basins were constructed more than 35 years ago as repositories for irradiated fuel from the K East and K West Reactors. Currently, the basins contain irradiated fuel from the N Reactor. To continue to use the basins as desired, seismic adequacy in accordance with current US Department of Energy facility requirements must be demonstrated. The 105-KE and 105-KW Basins are reinforced concrete, belowground reservoirs with a 16-ft water depth. The entire water retention boundary, which currently includes a portion of the adjacent reactor buildings, must be qualified for the Hanford Site design basis earthquake. The reactor building interface joints are sealed against leakage with rubber water stops. Demonstration of the seismic adequacy of these interface joints was initially identified as a key issue in the seismic qualification effort. The issue of water leakage through seismicly induced cracks was also ...

1991-10-15

444

Fuel cycle options and sustainability for new nuclear build in the UK  

International Nuclear Information System (INIS)

After a long period of stagnation in the UK, Europe and the USA, there is now a real expectation that new nuclear plants will be under construction shortly. Several factors have contributed to this change of position in the UK: the growing realisation that effective action is needed to offset greenhouse gas emissions; higher prices for fossil fuels; increasing reliance on overseas supplies of oil and gas; the limitations of wind and wave power and distribution; security of supply; the gradual realisation in the deregulated electricity generation market that nuclear power is competitive and the pending closure of most of the UK's nuclear fleet within less than 15 years. All these factors have led to a reversal of the UK Government's attitude to nuclear power, which has now ruled in favour of allowing a new generation of nuclear plants being built. This paper summarises some of the arguments that have led to this decision and the ramifications of it. In particular, the potential of the ...

2008-09-14

445

Final report of the European Passive Solar Modelling Sub-Group  

Energy Technology Data Exchange (ETDEWEB)

The task of selecting reliable computer programs to simulate the performance of passive solar buildings has been assigned by the CEC to a specialized sub-group, the Modelling Sub-Group. This group has selected a detailed program for large computers, which has been commissioned and run by each participant. It has also given a reference for the analysis of a set of simple models, i.e. for mini/micro computers, pocket calculators and manual methods. These simulation techniques have been analyzed by answering an original questionnaire, making test runs of the models with building and climatic data, and comparing the results obtained with the large program. The best manual method has been included in the Passive Solar Handbook prepared by the Passive Solar Working Group. The MSG has also established a comparative table of all the selected simplified models, in order to make the designer able to do a first selection among them, in accordance with the ...

1985-01-01

446

Field performance of an energy pile system for space heating  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the field performance of air conditioning with an energy pile system, which was applied to the pile foundations of an actual building for the purpose of reducing the cost of the underground heat exchanger. First, the building for both office and residential use, for which a space heating and cooling system using friction piles was installed, was built in Sapporo in December 2000. Second, three tests were carried out to specify the design of a heat exchanger inside the pile, and a U-tube type underground heat exchanger was adopted from the viewpoint of energy efficiency and installation costs. Long-term space heating operation measurements indicated that the seasonal average temperatures of brine returning from the underground and pile surfaces were 2.4 and 6.7 deg C, respectively. The average coefficient of performance for space heating was quite high at 3.9, and the seasonal primary energy reduction rate compared with a ...

2007-05-15

447

Feasibility study on Bobovdol thermal power plant upgrading project  

Energy Technology Data Exchange (ETDEWEB)

A survey has been made in relation with the improvement project intended of energy conservation, and reduction of global warming gas emission at the Bobovdol thermal power plant located in the suburb of Sofia, the capital of the Republic of Bulgaria. The existing Bobovdol power plant having a total capacity of 630 MW with three generators is a coal burning thermal power plant having been used already for 23 to 27 years, hence over-aged. The survey has discussed an improvement project of scrap-and-build type to make the plant a high-efficiency gas combined cycle power plant using gas turbines. The project calls for building 210-MW gas combined power generation facilities having 70-MW gas turbines, one each in three stages in 2007, 2012 and 2017. As a result of the discussions, the fuel consumption reducing rate was found to reach 37.99%, whereas the cumulative energy saving quantity in 41 years will reach 16.37 million tons of fuel oil ...

2001-03-01

448

Facility Effluent Monitoring Plan for Pacific Northwest National Laboratory Balance-of-Plant Facilities  

Energy Technology Data Exchange (ETDEWEB)

The Pacific Northwest National Laboratory (PNNL) operates a number of research and development (R and D) facilities for the Department of Energy on the Hanford Site. According to DOE Order 5400.1, a Facility Effluent Monitoring Plan is required for each site, facility, or process that uses, generates, releases, or manages significant pollutants or hazardous materials. Three of the R and D facilities: the 325, 331, and 3720 Buildings, are considered major emission points for radionuclide air sampling and thus individual Facility Effluent Monitoring Plans (FEMPs) have been developed for them. Because no definition of ''significant'' is provided in DOE Order 5400.1 or the accompanying regulatory guide DOE/EH-0173T, this FEMP was developed to describe monitoring requirements in the DOE-owned, PNNL-operated facilities that do not have individual FEMPs. The remainder of the DOE-owned, PNNL-operated facilities are referred to as ...

1999-04-02

449

Environmental impact assessment around TRIGA research reactor  

International Nuclear Information System (INIS)

Population distribution, atmospheric change, X/Q, characteristics of terrestrial ecosystem around Seoul site were surveyed. Environmental radiation and radioactivities such as gross#alpha#, gross#beta#, Cs-137, Sr-90 and H-3 of various environmental samples were analyzed. The values of environmental radiation dose tended to increase gradually in the light of the recent five years' results of environmental radiation monitoring around the nuclear power plants from 1980 to 1984, however, the changes were not significant. In addition, continuous assessment of environmental radiation monitoring on the roofs of main building and life science building at KAERI showed that the environmental radiation dose tended to increase a little during the night time. Judging from the above results, it is concluded that environmental contamination level by radioactive materials could be ignored in the case of radioisotope production or experiment using ...

1985-04-01

450

Economic production and processing of agricultural fibre plants for high quality applications in automotive, building and furniture industry  

Energy Technology Data Exchange (ETDEWEB)

The demand for high-quality fibres and shives from hemp and flax as an alternative raw material for the automotive and building industry is increasing. Fibres are used primarily for composite reinforcement instead of synthetic fibres. Shives are used for animal bedding, but processing trials in wood industry for the production of low weight particle boards from shives are also very promising. Fibre producers require experience in cultivation and harvesting as well as modern processing technologies in order to supply flax fibres or shives at competitive prices under the changing conditions of international raw material markets. A complete processing line has been developed, installed and tested at the Leibniz Institute for Agricultural Engineering (ATB) to study all the processing stages of fibre production. The new ATB line can produce high quality fibres and shives from retted and unretted hemp, flax and oilseed flax straw without technical changes of the machine ...

2010-07-01

451

Developing, financing and managing merchant (independent) power plants  

Energy Technology Data Exchange (ETDEWEB)

Deregulation and restructuring changes in the electric power industry have provided opportunities to build new power plants. These power plants, however, will not enjoy long-term power purchase agreements with the utilities they serve, but will have to respond to the market. This is where the term `merchant plant` originates. Calpine Corp. presented its reasons for believing that now is the best time to be building new merchant plants based on modern natural gas-fired, combined-cycle power plants. Among those reasons are: (1) construction of new nuclear power plants has been rejected by people on both sides of the border, (2) attempts to promote alternative energy sources such as solar, wind and biomass have not added significant generation capacity and are not likely to do so in the near future because of their high cost, and (3) coal-fired plants are also facing environmental challenges. For all these reasons, modern natural gas-fired, ...

1998-08-01

452

Detection of concealed mercury with thermal neutrons  

Energy Technology Data Exchange (ETDEWEB)

In the United States today, governments at all levels and the citizenry are paying increasing attention to the effects, both real and hypothetical, of industrial activity on the environment. Responsible modem industries, reflecting this heightened public and regulatory awareness, are either substituting benign materials for hazardous ones, or using hazardous materials only under carefully controlled conditions. In addition, present-day environmental consciousness dictates that we deal responsibly with legacy wastes. The decontamination and decommissioning (D&D) of facilities at which mercury was used or processed presents a variety of challenges. Elemental mercury is a liquid at room temperature and readily evaporates in air. In large mercury-laden buildings, droplets may evaporate from one area only to recondense in other cooler areas. The rate of evaporation is a function of humidity and temperature; consequently, different parts of a ...

1994-08-18

453

Design/build/mockup of the Waste Isolation Pilot Plant gas generation experiment glovebox  

Energy Technology Data Exchange (ETDEWEB)

A glovebox was designed, fabricated, and mocked-up for the WIPP Gas Generation Experiments (GGE) being conducted at ANL-W. GGE will determine the gas generation rates from materials in contact handled transuranic waste at likely long term repository temperature and pressure conditions. Since the customer`s schedule did not permit time for performing R&D of the support systems, designing the glovebox, and fabricating the glovebox in a serial fashion, a parallel approach was undertaken. As R&D of the sampling system and other support systems was initiated, a specification was written concurrently for contracting a manufacturer to design and build the glovebox and support equipment. The contractor understood that the R&D being performed at ANL-W would add additional functional requirements to the glovebox design. Initially, the contractor had sufficient information to design the glovebox shell. Once the shell design was approved, ANL-W built a full scale ...

1996-10-01

454

Consideration of the Change of Material Emission Signatures due to Longterm Emissions for Enhancing VOC Source Identification  

DEFF Research Database (Denmark)

The objectives of this study were to characterize the changes of VOC material emission profiles over time and develop a method to account for such changes in order to enhance a source identification technique that is based on the measurements of mixed air samples and the emission signatures of individual building materials determined by PTRMS. Source models, including powerlaw model, doubleexponential decay model and mechanistic diffusion model, were employed to track the change of individual material emission signatures by PTRMS over a ninemonth period. Samples of nine typical building materials were tested individually for nine months and later in combination to obtain actual mixture emissions. VOC emissions from each material were measured in a 50liter smallscale chamber. Chamber air was sampled by PTRMS over a 28day period to determine their emission rate decay characteristics as well as to establish the initial profile of emission ...

2011-01-01

455

Competency build up, sustained performance enhancement of human resource through effective man power planning, training and proper safety culture and organizational climate  

International Nuclear Information System (INIS)

Human resource competence building and continued enhancement of performance is the most vital input for safe and reliable operations of a Nuclear Power Plant. Integrated planning leading to the decision of timely selection of optimum number of fresh people and deployment of experienced manpower with desired lead time is inevitable to achieve the above objective. For safe and reliable plant operation human performance analysis followed by suggestive measures to improve the same is needed. Corrective or strengthening input may be in terms of training, work environment, motivations, organizational culture and climate, leadership and prevailing environmental force and bio-rhythm of individuals with critical days are to be worked out The adequacy in training and development not only gives safe and reliable plant operations but results in greater employee satisfaction and self esteem as well. As of date, in the present vibrant global scenario, only the organization which ...

2006-11-13

456

Biodrying of animal slaughterhouse residues and heat production  

Energy Technology Data Exchange (ETDEWEB)

Animal carcasses from slaughterhouses are usually composted on farms, but the composting process is not optimized and a large volumes of carbonaceous residues are needed. This type of composting takes place over a period of 6 to 9 months in a nonaerated static pile. Quebec's industrial research centre (CRIQ) developed an organic biodrying process (BIOSECO) adapted to large-scale operations in order to optimize the treatment of slaughterhouse residues. Biodrying is a form of composting, in which the thermophilic phase is optimized, making it possible to evaporate large amounts of water. Biodrying is done inside a building and reduces the amount of carbonaceous residues considerably. The process is optimized by the sequence in which the slaughterhouse residues are added, the choice of input and the aeration flow. Slaughterhouse residues can be treated non-stop throughout the entire year. Since the odours are nearly completed limited to the ...

2010-07-01

457

Analysis and evaluation of seismic response of reactor building for Daya Bay Nuclear Power Plant  

International Nuclear Information System (INIS)

Daya Bay NPP has been operating safely and stably over 10 years since 1994, and its' seismic analysis of nuclear island was in accordance with the approaches in RCC-G standard for the model M310, in which the Simplified Impedance Matrix Method (SIMM) was employed for the consideration of SSI. Thanks to the rapid progress being made in upgrading the evaluation technology and the capability of data processing systems, methods and software tools for the SSI analysis have experienced significant development all over the world. Focused on the model of reactor building of the Daya Bay NPP, in his paper the more sophisticated 3D half-space continuum impedance method based on the Green functions is used to analyze the functions of the soil, and then the seismic responses of the coupled SSI system are calculated and compared with the corresponding design values. It demonstrates that the design method provides a set of conservatively safe results. The conclusions from the ...

2005-12-01

458

Air conditioning system planning for Kanagawa Science Park (KSP) building. Kanagawa Science Park (KSP) no kuki chowa setsubi  

Energy Technology Data Exchange (ETDEWEB)

Urban type R D (research and development) facilities have research institute functions which are not desirable to coexist in a city as compared with suburban R D facilities. Therefore careful consideration must be given to environmental protection. KSP is the first large scale urban type R D facility in Japan. The planning and construction have been made with the theme of realization of flexibility in architecture and mechanical planning as well as realization of environmental integrity. To achieve the target so-called technical slit is built at the center of the building to provide a void space for securing natural ventilation. It is effective for provision of internal mechanical spaces without spoiling urban View air exhaust from laboratories natural ventilation for underground parking lots and decrease of damage by strong wind on the ground level. Standards are established and organization is formed for environmental administration to protect the environment. 4 ...

1991-12-05

459

Advanced Neutron Source: Plant Design Requirements. Revision 4  

Energy Technology Data Exchange (ETDEWEB)

The Advanced Neutron Source will be a new world-class facility for research using hot, thermal, cold, and ultra-cold neutrons. The heart of the facility will be a 330-MW (fission), heavy-water cooled and heavy-water moderated reactor. The reactor will be housed in a central reactor building, with supporting equipment located in an adjoining reactor support building. An array of cold neutron guides will fan out into a large guide hall, housing about 30 neutron research stations. Appropriate office, laboratory, and shop facilities will be included to provide a complete facility for users. The ANS is scheduled to begin operation at the Oak Ridge National Laboratory early in the next decade. This PDR document defines the plant-level requirements for the design, construction, and operation of ANS. It also defines and provides input to the individual System Design Description (SDD) documents. Together, this PDR document and the set of SDD documents ...

1990-07-01

460

Accelerator driven assembly  

Energy Technology Data Exchange (ETDEWEB)

This report addresses a Los Alamos National Laboratory (LANL) proposal to build a pulsed neutron source for simulating nuclear-weapons effects. A point design for the pulsed neutron facility was initiated early in FY94 after hosting a Defense Nuclear Agency (DNA) panel review and after subsequently visiting several potential clients and users. The technical and facility designs contained herein fulfill the Statement of Work (SOW) agreed upon by LANL and DNA. However, our point designs and parametric studies identify a unique, cost-effective, above-ground capability for neutron nuclear-weapons-effects studies at threat levels. This capability builds on existing capital installations and infrastructure at LANL. We believe that it is appropriate for us, together with the DNA, to return to the user community and ask for their comments and critiques. We also realize that the requirements of last year have changed significantly. Therefore, the ...

1997-01-01

461

ASTM residential green building standard guide development  

Energy Technology Data Exchange (ETDEWEB)

The authors have led development of a Standard Guide for Residential Green Buildings through the consensus process of the American Society for Testing and Materials (ASTM). The voluntary guidance document has been processed through two public peer reviews in ASTM`s E-50.06 sub-committee on the environment. The guide`s purpose is to present general criteria for home builders, residential designers and developers on how to systematically approach the creation of a green home--from the design phase on through to eventual de-commissioning of residential structures. This paper briefly reviews the standards process, includes an overview of the Standard Guides` principal criteria, and provides a robust resource listing for further investigation by readers. During development of the Standard Guide, authors emphasized thorough review of the available literature on sustainable residential development. This was then reflected in the technical contents of the Standard Guide to ...

1997-12-31

462

AN INFORMATION/NAVIGATION AID FOR COMPLEX INDOOR SPACE FEASIBILITY STUDY TO ESTABLISH OLDER PEOPLE'S NEEDS  

Environmental Research Database

Objectives1. To identify with older people the problems which they encounter in finding their way about public building/spaces.~%~2. To produce ideas, in consultation with older people, for an information/navigation aid that might facilitate their use and enjoyment of public buildings/spaces, notably hospitals, large shops, railway stations, airports.~%~3. To develop an emulation model of the information/navigation aid~%~4. To monitor use of the model by older people~%~5. To identify further research~%~6. [continued...]DescriptionThe growth in the number of older people offers scope for the development of customised information/navigation aids to help them to find their way around complex public spaces. New technology however is unlikely to be taken up by older people unless it is acceptable to them. The research will involve engineers in designing, testing and modifying a model of such an aid in conjunction with a sample of older ...

1999-01-31

463

A healthy climate for the Printer house. Indoor climate improved by means of adjucting the air conditioning installation; Een gezond klimaat voor het Printerhuis. Binnenklimaat verbetert dankzij aanpassing LBK  

Energy Technology Data Exchange (ETDEWEB)

In the first part of the nineties many office buildings were equipped with indoor climate installations which do not meet present standards. Several options are available to improve such installations for ventilation capacity, cooling capacity, thermal comfort and air quality. One of the options concern the installation of an air conditioner in combination with heat recovery. In this article attention is paid to the renovation of the air conditioning system in the Printer house, an office building in Zwolle, Netherlands. [Dutch] Begin jaren negentig zijn veel kantoorpanden gebouwd waarvan de klimaatinstallatie tegenwoordig niet meer voldoet. De ventilatiecapaciteit is ontoereikend en koeling is mondjesmaat aanwezig, of slechts als topkoeling. Het comfort en de luchtkwaliteit zijn dan ook onder de maat. Er zijn verschillende mogelijkheden om dit te verbeteren. Plaatsing van een nieuwe luchtbehandelingskast met warmteterugwinning is daar een van. ...

2007-05-15

464

A habitat template approach to green building surfaces  

Energy Technology Data Exchange (ETDEWEB)

The use of entire plant communities of native species is gaining interest in the green roof industry. Plant communities must be matched with environmental conditions that mimic conditions in their original habitats. Urban built environments do not differ significantly from the rocky outcrops with poor, shallow soil that many plants colonize. This paper provided details of an experiment investigating the impact of plant community structure and species diversity on living roof performance. The aim of the experiment was to determine the impact of species diversity on precipitation interception, nutrient retention, temporal biomass constancy and roof temperature constancy. The diversity treatment included separate monocultures of 8 species in the community, randomly determined mixtures of 4 species, and a mixture of all 8. Functional groups included mosses, liverworts, colonial algae and a mycorrhizal inoculum. In a second experiment, between 1 and 4 of the functional groups were added to ...

2005-07-01

465

[Fritz hauschild (1908-1974) and drug research in the 'German Democratic Republic' (GDR)].  

Science.gov (United States)

The chemist and pharmacologist Fritz Hauschild developed the sympathomimetic agent Pervitin (metamphetamin) in the 1930s. Not only because of the abuse of the stimulant during the Second World War ("pilot's chocolate") it is one of the most controversial substances in drug history. Nearly forgotten are Hauschild's contributions to build up the drug system in the GDR. Although he was a convinced communist, the skilful pharmacologist gave very early warning of the imminent lack of innovation in the GDR pharmaceutical industry. A letter which he addressed to the Minister of Health, Max Sefrin (born 1913), did not lack explicitness. PMID:15997840

2005-06-01

466

The new thermal comfort equation to qualify air in buildings. De nieuwe behaaglijkheidsbalans voor de kwaliteit van de lucht in gebouwen  

Energy Technology Data Exchange (ETDEWEB)

In the 1988 February issue of this magazine the units olf and decipol were introduced. Olf is a measure for the pollution load and decipol for the indoor air quality. This article discusses a new ventilation theory which is quantified by the new indoor air quality thermal comfort balance based on the units olf and decipol. This balance requires more ventilation air than for the present regulations. It takes into account all pollution sources. 2 figs., 9 refs., 3 tabs.

1990-05-01

467

The need for action in the housing ventilation area is essential; Bei der Wohnungslueftung besteht grosser Handlungsbedarf  

Energy Technology Data Exchange (ETDEWEB)

This short article discusses the results of a market survey on ventilation systems for residential buildings and the role played by ventilation systems in our daily lives. Problems incurred as a result of insufficient ventilation conditions such as the formation of mould in dwellings whose windows have been replaced with better seals are discussed, for example. The negative image of air-conditioning and its causes are examined. The need for action in this area is stressed. Further findings of the study are presented, including a detailed review of current equipment and scenarios on how these systems can develop in the future. The extension of the study to cover the situation in further European countries is mentioned.

2003-07-01

468

The AECL's research reactor analysis methodology  

International Nuclear Information System (INIS)

As the cost of developing completely new computer codes becomes prohibitive, designers of nuclear facilities are turning to more cost-effective approaches for meeting increasingly strict regulatory requirements applied to safety-related analysis. For designing and licensing the MAPLE family of research reactors, Atomic Energy of Canada Ltd. (AECL) is employing the strategy of adapting major existing codes by linking them together within networks of custom-built interface software. This approach builds on the international investment in developing, maintaining, and verifying existing primary codes and focuses on the less onerous development of interface codes. The resultant code systems are then validated for the new applications of interest.

469

THE IMPACT OF CROWDFUNDING ON JOURNALISM  

British Library Electronic Table of Contents (United Kingdom)

This article analyzes the impact of crowdfunding on journalism. Crowdfunding is defined as a way to harness collective intelligence for journalism, as readers' donations accumulate into judgments about the issues that need to be covered. The article is based on a case study about Spot.Us, a platform pioneering community-funded reporting. The study concludes that a crowdfunded journalistic process requires journalists to renegotiate their role and professional identity to succeed in the changing realm of creative work. The study concludes that reader donations build a strong connection from the reporters to the donors, which creates a new sense of responsibility to the journalists. The journalists perceive donors as investors, that cannot be let down. From the donor's perspective, donating ...

2011-01-01

470

Summary of Uranium City, Saskatchewan remedial measures for radiation reduction with special attention to vent fan theory  

International Nuclear Information System (INIS)

Various remedial measures have been tried to lower radon levels in buildings in Uranium City. The methods used are source material removal, passive ventilation of crawl spaces, sub-floor ventilation, complete epoxy coating of the entire basement, sealants for floor-wall joints and cracks in basements, electrostatic precipitators, mechanical ventilation, and sealing and grouting concrete block plenums in basement walls. The type and condition of structures encountered in Uranium City as well as the relative isolation of the town indicate that mechanical ventilation is the most long-term cost-effective method.

1980-03-12

471

Studies on the CRUD Deposition on Fuel Cladding Surface Using AOA Water Chemistry Loop  

International Nuclear Information System (INIS)

Axial offset anomaly (AOA) is caused by the deposition of crud on the fuel cladding of a PWR. When significant levels of crud build up on the cladding, boron can accumulate in the pores of the crud as a concentrated solution or solid phase, and cause the flux depression. Numerous studies have been conducted on the primary water chemistry to reduce the amount of crud in the primary circuit to avoid radioactivity buildup and unexpected power transition in the plant. However, experiments on the crud are restricted in the laboratory because the crud is a highly radioactive material. The objective of this study is to develop a test method for simulating the deposition of crud in a nuclear power plant

2010-10-01

472

Space activities in the Bolivarian Republic of Venezuela  

British Library Electronic Table of Contents (United Kingdom)

This paper summarizes the establishment and current development of space activities in the Bolivarian Republic of Venezuela. Space activities in Venezuela are focused on the areas of telecommunications, Earth observation and research on the physical properties of the Earth, and have as a primary goal the satisfaction of social needs. Current development of space activities started in 1999 when the new National Constitution recognized the value of outer space as the common heritage of mankind, and the key role of science and technology in promoting human welfare. The Bolivarian Agency for Space Activities (ABAE) was created in 2007. Its legal framework recognizes three key elements that drive its policy: the participation of society, capacity building and human training, and international c...

2011-01-01

473

Review of ion accelerators  

Energy Technology Data Exchange (ETDEWEB)

The field of ion acceleration to higher energies has grown rapidly in the last years. Many new facilities as well as substantial upgrades of existing facilities have extended the mass and energy range of available beams. Perhaps more significant for the long-term development of the field has been the expansion in the applications of these beams, and the building of facilities dedicated to areas outside of nuclear physics. This review will cover many of these new developments. Emphasis will be placed on accelerators with final energies above 50 MeV/amu. Facilities such as superconducting cyclotrons and storage rings are adequately covered in other review papers, and so will not be covered here.

1990-06-01

474

Proceedings of the Canadian Society for Bioengineering CSBE/SCGAB 2008 annual meeting  

Energy Technology Data Exchange (ETDEWEB)

This conference provided a forum to discuss advances in the application of bioengineering principles and practices dealing with biological systems for the production of food, bioproducts and energy. The topics of discussion ranged from engineering practices in agriculture, forestry, bioresources, biochemistry and biosystems. The sessions of the conference were entitled: renewable energy; waste management; soil and water; machinery systems; building and storage systems; and bioproducts and food. The conference also featured a workshop on integrated biomass supply and logistics. In addition to 20 posters, the conference featured 67 presentations, of which 3 have been catalogued separately for inclusion in this database. refs., tabs., figs.

2008-07-01

475

Passive dosimetry of radon and its daughters using solid state nuclear track detectors (SSNTDs)  

Energy Technology Data Exchange (ETDEWEB)

Indoor radon is a potential health hazard for the general public, especially in buildings with poor ventilation. A variety of dosemeters have been developed and used in surveys of radon concentration measurements. In this article the passive dosemeters which are based on solid state nuclear track detectors are reviewed. The principle of passive dosimetry and the factors affecting their performance are discussed. The characteristics of SSNTD materials in relation to their behaviour under different environmental conditions are tabulated and discussed. Results of radon surveys from selected studies are also presented. (Author).

1993-01-01

476

Ozone removal by green building materials  

Energy Technology Data Exchange (ETDEWEB)

Interest in finding out passive ways to keep the variation in the indoor climate within the comfort zone is gaining in popularity. One possible solution is the use of the moisture-buffering property of materials. In this study, the effects of the ventilation system and moisture-buffering properties of the building fabric on the stability of the indoor temperature and humidity are analysed by means of long-term field measurements. Indoor climate measurements were carried out in 170 detached houses (248 rooms). Temperature and relative humidity were measured continuously in bedrooms and living rooms at one-hour intervals over a one-year period. In general, it may be concluded that in this study, the ventilation had a greater effect on the indoor climate than the properties of the building fabric. The dampening effect of hygroscopic materials was remarkably less in the field measurements than it was in simulations in different studies. This ...

2009-08-15

477

Nuclear power and uranium development: a Saskatchew perspective  

International Nuclear Information System (INIS)

Saskatchewan boasts the greatest concentration of high-grade uranium of any place in the world. Properly managed, its current reserves of 238U can easily fuel the entire province for some 10,000 years (in comparison, the world's oil supplies may be gone in 100). It is likely that Saskatchewan, with all that uranium, can build an industry and renew Canada's nuclear dream. The authors believe in the value of nuclear energy, in general, and the value of uranium mining in Saskatchewan and other parts of the world, in particular. We also believe in the value of research, development, innovation and training in the nuclear industry and the uranium industry

478

NAME=\\  

Wastenet

...Rolls Royce Production Plant, Goodwood Rolls Royce Production Plant, Goodwood Rolls Royce Production Plant, Goodwood Browser does not support script. Home ...Wilson Group plc »Projects »Buildings & Infrastructure »Industrial & Distribution »Rolls Royce Production Plant, Goodwood Rolls Royce Production Plant, Goodwood Project Introduction Scott Wilson was ...Robin Hood Airport Robin Hood Airport Doncaster Sheffield Rolls Royce Production Plant, Goodwood Rolls-Royce plc Rolls-Royce plc, New Manufacturing Facility Royal Arsenal Development ...

479

Multicriteria analysis of ventilation in summer period  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a multicriteria analysis of ventilation during summertime in Europe. Multicriteria analysis theories are used to determine the most suitable ventilation strategy on a university building, that is to say to ensure the best possible indoor air quality, thermal comfort of the occupants and the lower energy consumption in case of accelerated diurnal or nocturnal ventilation and/or air conditioning. After defining the possible actions, the criteria of quality regarding thermal comfort, indoor air quality and energy consumption are defined. The possible actions are then assessed relative to each of these three criteria and ranked from the best to the worst ones using two different multicriteria analysis methods. (author)

2002-02-01

480

Metalloid Cluster Compounds of Group 14: Bonding Properties and Subsequent Reactions  

British Library Electronic Table of Contents (United Kingdom)

Metalloid cluster compounds of group 14 of the general formulae EnRm with n > m (E = Si, Ge, Sn, Pb; R = ligand), where naked as well as ligand bound tetrel atoms are present, represent a novel class of cluster compounds in group 14 chemistry and can be seen as intermediates on the way to the elemental state. Therefore, interesting properties are expected for these compounds, which might complement results from nanotechnology. In this article, first results for germanium are discussed, together with novel build-up reactions on the way to novel materials based on metalloid cluster compounds. GRAPHICAL ABSTRACT[image omitted

2011-01-01

481

Mastery of risks: we build the memory of radioactive waste disposal facilities  

International Nuclear Information System (INIS)

The ANDRA, the French national agency of radioactive wastes, is organizing today the information needs of tomorrow. The aim is to allow the future generations to have access to the knowledge of the existence of subsurface radioactive waste facilities and to understand the context and technologies of such facilities. The storage of this information is made on 'permanent paper', a high resistant paper with a lifetime of 600 to 1000 years. An updating of these data is made every 5 years for each waste disposal center. Another project, still in progress, concerns the memory management of deep geologic waste disposal facilities for which the time scale to be considered is of the order of millennia. (J.S.)

482

Improving air quality in tertiary buildings; Ameliorer la qualite de l'air dans les batiments tertiaires  

Energy Technology Data Exchange (ETDEWEB)

In order to promote the use of natural gas air-conditioning systems in the tertiary sector, Gaz de France (the French gas utility) in association with Electricite de France (EdF) and the French chamber of council engineers (CICF) have created the Acerclim organization which aims at certifying the quality of the design, realization and exploitation of air processing and air-conditioning installations according to the ISO 9001 criteria. This article describes this quality procedure named 'CHSB Air'. (J.S.)

2002-07-01

483

INSPIRE - The Next-Generation HEP Information System  

CERN Document Server

CERN, DESY, Fermilab and SLAC have joined forces to build INSPIRE, the next-generation HEP information platform offering innovative tools for information discovery and communication. Representing a natural community-based evolution of SPIRES, INSPIRE provides fast access to the entire body of HEP literature. As a subject repository it will host fulltexts of preprints, Open Access journal articles and supplementary material like conference slides and multimedia, enabling novel text- and data mining applications. In the spirit of Web2.0 INSPIRE will also supply tools for collaboration and user-enriched content.

2010-01-01

484

Hybrid ventilation. Control strategies for hybrid ventilation, consequences for air quality, thermal comfort and energy use; Hybrid ventilasjon  

Energy Technology Data Exchange (ETDEWEB)

This article deals with the need for control strategies and control systems in buildings with hybrid ventilation. In this respect, control strategies are methods of keeping certain parameters like temperature, air quality etc within specified limits. A control system is automatic and includes sensors, motors, dampers etc. The article also discusses consequences with respect to thermal comfort, air quality and energy use following selection of control parameters for controlling air masses.

2001-07-01

485

Higher spin symmetries and w_#infinity# algebra in the conformal affine Toda model  

International Nuclear Information System (INIS)

As recently shown the conformal affine Toda models can be obtained via hamiltonian reduction from a two-loop Kac-Moody algebra. In this paper we propose a systematic procedure to analyze the higher spin symmetries of the conformal affine Toda models. The method is based on an explicit construction of infinite towers of extended conformal symmetry generators. Two fundamental building blocks of this construction are special spin-one and -two primary fields characterizing the conformal structure of these models. The connection to the algebra of area preserving diffeomorphisms on a two-manifold (w_#infinity# algebra) is established. (orig.).

1992-05-01

486

High Exposure Facility Technical Description  

Energy Technology Data Exchange (ETDEWEB)

The High Exposure Facility is a collimated high-level gamma irradiator that is located in the basement of the 318 building. It was custom developed by PNNL back in 1982 to meet the needs for high range radiological instrument calibrations and dosimeter irradiations. At the time no commercially available product existed that could create exposure rates up to 20,000 R/h. This document is intended to pass on the design criteria that was employed to create this unique facility, while maintaining compliance with ANSI N543-1974, "General Safety Standard for Installations Using Non-Medical X-Ray and Sealed Gamma-Ray Sources, Energies up to 10 MeV."

2008-02-12

487

Heating and cooling with the building mass; Mit der Gebaeudemasse heizen und kuehlen  

Energy Technology Data Exchange (ETDEWEB)

A Paderborn group of builder-owners decided in favour of so-called concrete core activation or isothermal component tempering as an alternative to conventional air conditioning. Results are now available for the first year of operation. [German] Am eigenen Neubau hat eine Paderborner Bauherrengemeinschaft die sogenannte Betonkernaktivierung - oder wie es die Bauherren nennen, isotherme Baukoerpertemperierung - als Alternative zu einer konventionellen Klimaanlage installiert. Inzwischen liegen die Messergebnisse von der ueber einjaehrigen Betriebszeit vor. (orig.)

2000-08-01

488

Geothermal heat pump performance and utility programs in the United States  

Energy Technology Data Exchange (ETDEWEB)

Geothermal heat pump systems are a promising new energy technology that has shown rapid increase in usage over the past 10 years in the United States. These systems offer substantial benefits to consumers and utilities in energy (kWh) and demand (kW) savings. The purpose of this study was to determine what existing monitored data were available mainly from electric utilities on heat pump performance, energy savings, and demand reduction for residential, school, and commercial building applications. Information was developed on the status of electric utility marketing programs, barriers to market entry, incentive programs, and benefits.

1997-01-01

489

Geothermal heat pump performance  

Energy Technology Data Exchange (ETDEWEB)

Geothermal heat pump systems are a promising new energy technology that has shown rapid increase in usage over the past ten years in the United States. These systems offer substantial benefits to customers and utilities in energy (kWh) and demand (kW) savings. The purpose of this study was to determine what existing monitored data was available mainly from electric utilities on heat pump performance, energy savings and demand reduction for residential, school, and commercial building applications. Information was developed on the status of electric utility marketing programs, barriers to market penetration, incentive programs, and benefits.

1995-12-31

490

Finite element prediction of differential eddy current probe signals from Fe _30_4 deposits in PWR steam generators  

International Nuclear Information System (INIS)

The paper is concerned with the simulation of practical testing situations which are too difficult and/or expensive to replicate in a laboratory environment. Numerical experiments are described which simulate the differential eddy current probe response to the build-up and chemical flushing of magnetite in the crevice gap of a PWR steam generator unit. The simulation results agree well with the only experimental data available to the authors and lead to the conclusion that conventional differential eddy current probes should be capable of characterizing crevice gap conditions with respect to the presence of magnetite. (author).

1985-01-01

491

Field applications of a radon barrier to reduce indoor airborne progeny  

International Nuclear Information System (INIS)

The use of uranium mill tailings in the foundations of dwellings has resulted in indoor radon progeny concentrations and gamma exposures in excess of levels presently allowed for the general public. An account is given of the applications of an epoxy coating on the indoor faces of the concrete foundations of three buildings in Grand Junction, Colorado. Epoxy barriers were shown to be effective for preventing radon influx into structures. Gamma exposure rates must be analyzed to ensure that buildup behind the barrier will not introduce an unacceptable gamma exposure level. The use of a sealant is especially economical in situations where structural integrity may be jeopardized by physical removal of uranium mill tailings. (author).

492

Different paths: gender, immigration and political participation.  

Science.gov (United States)

"Building on arguments made by Grasmuck and Pessar (1991), Hardy-Fanta (1993), and Hondagneu-Sotelo (1994), among others, this article makes the case for a gendered understanding of immigrant political socialization. Looking at recent Latin American immigrants to New York City, the article argues that immigrant Latino men are more likely to favor continuity in patterns of socialization and organization, and immigrant Latinas are more likely to favor change. This finding helps bridge theoretical and empirical literatures in immigration studies, applying the logic of gender-differentiated decisionmaking to the area of immigrant political socialization and behavior." PMID:12293595

1998-01-01

493

Developing with Ext GWT Enterprise RIA Development  

CERN Document Server

Developing in Ext GWT is a fast--paced, practical guide to quickly learning the tasks necessary in building enterprise--class Rich Internet Applications. Based around the exciting new UI library from Ajax leaders Ext JS and the latest GWT release, this book takes the reader through setup, the available widgets, and advanced custom widgets and templates, and concludes with a functional sample client--server application in less than 150 pages. Not your typical beginner's guide to programming, this book provides a rapid approach to becoming effective with leading commercial RIA tools and librarie

2009-01-01

494

Corrosion 2003. Conference papers on CD-ROM  

Energy Technology Data Exchange (ETDEWEB)

Papers are presented under 38 symposia. Subjects included reinforced concrete, protective coatings and linings, cathodic/anodic protection, chemical cleaning of boilers, managing corrosion with plastics, water treatment, HRSG boiler tube failure analysis, corrosion in oil and gas production, corrosion in petroleum refining and gas, processing, pipelines and tanks, high temperature materials, chemical process industry, aerospace equipment, materials technology developments for incinerators and waste fuel-fired processors, materials and corrosion in fossil-fuels conversion and combustion, corrosion in nuclear systems, marine corrosion, building systems, corrosion mechanisms, corrosion inhibitors and corrosion monitoring and measurement.

2003-07-01

495

Choice of distance from radiation source to tested object for gamma-absorption density measurer in divergent pencil of ray  

International Nuclear Information System (INIS)

Formulae are derived for estimation of the effect of gamma beam divergence on the value of systematic and statistical components of the errors of density measurement in production of structural materials and products also in the process of exploitation of building structures and constructions. Engineering technique for choice of the distance between radiation source and object under test is developed for absorption radioisotope densimeter operating by the scheme of geometry of divergent beam with amplitude compensation of backscattered radiation effect. The assessment of radioisotope densimeter efficiency providing the error of density measurement prescribed at design stage

496

An estimate of the response of a telephone repeater to a wideband pulse using FAAT techniques  

Energy Technology Data Exchange (ETDEWEB)

The purpose of a FAAT analysis is to estimate the probability of system upset to an electromagnetic threat, for systems on which we have incomplete information. As an example of this process, we will discuss the response of part of a telephone repeater system to wideband transients. We first estimate the currents induced on above-ground and buried cables. After that, we describe the simple circuit we used to build a model of the amplifier and protective devices. Finally, we describe the scaling of the energy deposited in the electronics, including its nonlinear large-signal response, with the amplitude of the wideband waveforms.

1992-09-01

497

A theoretical evaluation of solar-powered desiccant cooling in the United Kingdom  

Energy Technology Data Exchange (ETDEWEB)

Desiccant cooling is a potentially environmentally friendly technology that can be used to condition the internal environment of buildings. Unlike conventional air conditioning systems, which rely on electrical energy to drive the cooling cycle, desiccant cooling is a heat-driven cycle. This paper follows on from an initial study by the authors, and uses real meteorological data to evaluate the potential in the United Kingdom of using solar energy to drive the desiccant cooling cycle. Through the use of parametric studies, the paper investigates the energy consumption and costs associated with desiccant cooling. (author)

1999-07-01

498

A study of aging effects in gas proportional detectors at the BAC calorimeter of the ZEUS experiment  

Energy Technology Data Exchange (ETDEWEB)

The multicell proportional chambers at the backing calorimeter of the ZEUS experiment at the storage ring HERA are supplied with a gas mixture of Ar/CO[sub 2] by an open gas system. Flow proportional counters with the build-up [sup 55]Fe sources are used as gas system monitoring detectors. The ZEUS experiment is planned to collect data for about 10 years. Therefore, the lifetime of the Ar/CO[sub 2] mixture should be known. In this paper, the results of laboratory tests and preliminary measurements of the aging effects for monitoring counters are presented. ((orig.))

1994-09-01